  1. Surface profile measurement by using the integrated Linnik WLSI and confocal microscope system

    Science.gov (United States)

    Wang, Wei-Chung; Shen, Ming-Hsing; Hwang, Chi-Hung; Yu, Yun-Ting; Wang, Tzu-Fong

    2017-06-01

    The white-light scanning interferometer (WLSI) and confocal microscope (CM) are the two major optical inspection systems for measuring three-dimensional (3D) surface profile (SP) of micro specimens. Nevertheless, in practical applications, WLSI is more suitable for measuring smooth and low-slope surfaces. On the other hand, CM is more suitable for measuring uneven-reflective and low-reflective surfaces. As for aspect of surface profiles to be measured, the characteristics of WLSI and CM are also different. WLSI is generally used in semiconductor industry while CM is more popular in printed circuit board industry. In this paper, a self-assembled multi-function optical system was integrated to perform Linnik white-light scanning interferometer (Linnik WLSI) and CM. A connecting part composed of tubes, lenses and interferometer was used to conjunct finite and infinite optical systems for Linnik WLSI and CM in the self-assembled optical system. By adopting the flexibility of tubes and lenses, switching to perform two different optical measurements can be easily achieved. Furthermore, based on the shape from focus method with energy of Laplacian filter, the CM was developed to enhance the on focal information of each pixel so that the CM can provide all-in-focus image for performing the 3D SP measurement and analysis simultaneously. As for Linnik WLSI, eleven-step phase shifting algorithm was used to analyze vertical scanning signals and determine the 3D SP.

  2. Design of measurement system of 3D surface profile based on chromatic confocal technology

    Science.gov (United States)

    Wang, An-su; Xie, Bin; Liu, Zi-wei

    2018-01-01

    Chromatic confocal 3D profilometer has widely used in science investigation and industry fields recently for its high precision, great measuring range and numerical surface characteristic. It can provide exact and omnidirectional solution for manufacture and research by 3D non-contact surface analysis technique. The article analyzes the principle of surface measurement with chromatic confocal technology, and provides the designing indicators and requirements of the confocal system. As the key component, the dispersive objective used to achieve longitudinal focus vibration with wavelength was designed. The objective disperses the focus of wavelength between 400 700 nm to 15 mm longitudinal range. With selected spectrometer, the resolution of chromatic confocal 3D profilometer is no more than 5 μm, which can meet needs for the high precision non-contact surface profile measurement.

  3. Comparison of two methods of surface profile extraction from multiple ultrasonic range measurements

    NARCIS (Netherlands)

    Barshan, B; Baskent, D

    Two novel methods for surface profile extraction based on multiple ultrasonic range measurements are described and compared. One of the methods employs morphological processing techniques, whereas the other employs a spatial voting scheme followed by simple thresholding. Morphological processing

  4. Design and verification of the miniature optical system for small object surface profile fast scanning

    Science.gov (United States)

    Chi, Sheng; Lee, Shu-Sheng; Huang, Jen, Jen-Yu; Lai, Ti-Yu; Jan, Chia-Ming; Hu, Po-Chi

    2016-04-01

    As the progress of optical technologies, different commercial 3D surface contour scanners are on the market nowadays. Most of them are used for reconstructing the surface profile of mold or mechanical objects which are larger than 50 mm×50 mm× 50 mm, and the scanning system size is about 300 mm×300 mm×100 mm. There are seldom optical systems commercialized for surface profile fast scanning for small object size less than 10 mm×10 mm×10 mm. Therefore, a miniature optical system has been designed and developed in this research work for this purpose. Since the most used scanning method of such system is line scan technology, we have developed pseudo-phase shifting digital projection technology by adopting projecting fringes and phase reconstruction method. A projector was used to project a digital fringe patterns on the object, and the fringes intensity images of the reference plane and of the sample object were recorded by a CMOS camera. The phase difference between the plane and object can be calculated from the fringes images, and the surface profile of the object was reconstructed by using the phase differences. The traditional phase shifting method was accomplished by using PZT actuator or precisely controlled motor to adjust the light source or grating and this is one of the limitations for high speed scanning. Compared with the traditional optical setup, we utilized a micro projector to project the digital fringe patterns on the sample. This diminished the phase shifting processing time and the controlled phase differences between the shifted phases become more precise. Besides, the optical path design based on a portable device scanning system was used to minimize the size and reduce the number of the system components. A screwdriver section about 7mm×5mm×5mm has been scanned and its surface profile was successfully restored. The experimental results showed that the measurement area of our system can be smaller than 10mm×10mm, the precision reached to

  5. The prediction of BRDFs from surface profile measurements

    International Nuclear Information System (INIS)

    Church, E.L.; Takacs, P.Z.; Leonard, T.A.

    1989-01-01

    This paper discusses methods of predicting the BRDF of smooth surfaces from profile measurements of their surface finish. The conversion of optical profile data to the BRDF at the same wavelength is essentially independent of scattering models, while the conversion of mechanical measurements, and wavelength scaling in general, are model dependent. Procedures are illustrated for several surfaces, including two from the recent HeNe BRDF round robin, and results are compared with measured data. Reasonable agreement is found except for surfaces which involve significant scattering from isolated surface defects which are poorly sampled in the profile data

  6. Indirect measurement of near-surface velocity and pressure fields based on measurement of moving free surface profiles

    International Nuclear Information System (INIS)

    Sibamoto, Yasuteru; Nakamura, Hideo

    2005-01-01

    A non-intrusive technique for measurement of the velocity and pressure fields adjacent to a moving fluid surface is developed. The technique is based on the measurement of fluid surface profile. The velocity and pressure fields are derived with use of the boundary element method (BEM) by seeking for an incompressible flow field that satisfies the kinematic boundary condition imposed by the time-dependent fluid surface profile. The proposed technique is tested by deriving the velocity and pressure fields inversely from the fluid surface profiles obtained by a forward BEM calculation of fluid surface response to externally-imposed pressure. The inverse calculation results show good agreement with the imposed pressure distribution in the forward calculation. (author)

  7. Surface profiling interferometer

    Science.gov (United States)

    Takacs, Peter Z.; Qian, Shi-Nan

    1989-01-01

    The design of a long-trace surface profiler for the non-contact measurement of surface profile, slope error and curvature on cylindrical synchrotron radiation (SR) mirrors. The optical system is based upon the concept of a pencil-beam interferometer with an inherent large depth-of-field. The key feature of the optical system is the zero-path-difference beam splitter, which separates the laser beam into two colinear, variable-separation probe beams. A linear array detector is used to record the interference fringe in the image, and analysis of the fringe location as a function of scan position allows one to reconstruct the surface profile. The optical head is mounted on an air bearing slide with the capability to measure long aspheric optics, typical of those encountered in SR applications. A novel feature of the optical system is the use of a transverse "outrigger" beam which provides information on the relative alignment of the scan axis to the cylinder optic symmetry axis.

  8. LASSI - A Scanning Differential Ac Interferometer For Surface Profile And Roughness Measurement

    Science.gov (United States)

    Makosch, Guenter

    1989-03-01

    LASSI (Laser Spot Scanning Interferometer) is a highly precise and versatile surface profilometer developed for various measurement applications in surface lapping, etching and polishing processes. The principle of measurement is based on a differential interferometer in which two parallel light beams split from a He-Ne laser are scanned across a sample surface. The phase difference of the reflected beams changes proportionally with the height variation between the two spots illuminated on the surface. In using a phase-locked method to determine the phase differences height variations of a surface can be measured with manometer precision. The range of applications of an instrument built on this principle encompasses step height, roughness, slope, and profile measurement of surface microtopographies. Special versions of this tool have also been developed for in situ monitoring of etch or deposition rates in sputter-etching and wet etching processes. In this paper, the principle of measurement will be described and some theoretical aspects of the measurement technique will be discussed. The various LASSI tools and their applications are reviewed.

  9. All-silicon Michelson instrument on chip: Distance and surface profile measurement and prospects for visible light spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Malak, M.; Marty, F.; Bourouina, T. [Universite Paris-Est, Laboratoire ESYCOM, ESIEE Paris, Cite Descartes, 2 Boulevard Blaise Pascal, 93162 Noisy-le-Grand Cedex (France); Nouira, H.; Vailleau, G. [Laboratoire National de Metrologie et d' Essais, 1 rue Gaston Boissier, 75724 Paris Cedex 15 (France)

    2013-04-08

    A miniature Michelson interferometer is analyzed theoretically and experimentally. The fabricated micro-interferometer is incorporated at the tip of a monolithic silicon probe to achieve contactless distance measurements and surface profilometry. For infrared operation, two approaches are studied, based on the use of monochromatic light and wavelength sweep, respectively. A theoretical model is devised to depict the system characteristics taking into account Gaussian beam divergence and light spot size. Furthermore, preliminary results using visible light demonstrate operation of the probe as a visible light spectrometer, despite silicon absorbance, thanks to the micrometer thickness involved in the beam splitter.

  10. All-silicon Michelson instrument on chip: Distance and surface profile measurement and prospects for visible light spectrometry

    International Nuclear Information System (INIS)

    Malak, M.; Marty, F.; Bourouina, T.; Nouira, H.; Vailleau, G.

    2013-01-01

    A miniature Michelson interferometer is analyzed theoretically and experimentally. The fabricated micro-interferometer is incorporated at the tip of a monolithic silicon probe to achieve contactless distance measurements and surface profilometry. For infrared operation, two approaches are studied, based on the use of monochromatic light and wavelength sweep, respectively. A theoretical model is devised to depict the system characteristics taking into account Gaussian beam divergence and light spot size. Furthermore, preliminary results using visible light demonstrate operation of the probe as a visible light spectrometer, despite silicon absorbance, thanks to the micrometer thickness involved in the beam splitter.

  11. The Use of 2D Plastic Grating for Surface Profile and Dimension Manufacture Product Measurements by Using NDT Moiré Technique

    Directory of Open Access Journals (Sweden)

    Retno Wigajatri Purnamaningsih

    2010-10-01

    Full Text Available Research of measuring the shape and dimension of object using the moiré technique have been done. Measurement have been made by observing the moiré space as a result of interaction between grating and its shadow casted on the object's surface caused by the projector lamp with CCD camera. The acquired data was further processed by way of off-line. By successive phase shifts that is π/2, π dan 3π/2 towards the table tennis ball at the distance of 48 cm from the light source and CCD camera, with the distance between CCD Camera and light source 13,5 cm and grating space 0,5 mm. It was obtained that convex shape can be identified by resolution of 0,24 mm. It was also shown that the biggest difference between the results of using moiré technique and the use of CMM contact measurements (Coordinate Measuring Machine was 0,3 mm

  12. Gyral Folding Pattern Analysis via Surface Profiling

    Science.gov (United States)

    Li, Kaiming; Guo, Lei; Li, Gang; Nie, Jingxin; Faraco, Carlos; Cui, Guangbin; Zhao, Qun; Miller, L. Stephen; Liu, Tianming

    2010-01-01

    Folding is an essential shape characteristic of the human cerebral cortex. Descriptors of cortical folding patterns have been studied for decades. However, many previous studies are either based on local shape descriptors such as curvature, or based on global descriptors such as gyrification index or spherical wavelets. This paper proposes a gyrus-scale folding pattern analysis technique via cortical surface profiling. Firstly, we sample the cortical surface into 2D profiles and model them using a power function. This step provides both the flexibility of representing arbitrary shape by profiling and the compactness of representing shape by parametric modeling. Secondly, based on the estimated model parameters, we extract affine-invariant features on the cortical surface, and apply the affinity propagation clustering algorithm to parcellate the cortex into cortical regions with strict hierarchy and smooth transitions among them. Finally, a second-round surface profiling is performed on the parcellated cortical surface, and the number of hinges is detected to describe the gyral folding pattern. We have applied the surface profiling method to two normal brain datasets and a Schizophrenia patient dataset. The experimental results demonstrate that the proposed method can accurately classify human gyri into 2-hinge, 3-hinge and 4-hinge patterns. The distribution of these folding patterns on brain lobes and the relationship between fiber density and gyral folding patterns are further investigated. Results from the Schizophrenia dataset are consistent with commonly found abnormality in former studies by others, which demonstrates the potential clinical applications of the proposed technique. PMID:20472071

  13. 3D Surface Profile and Color Stability of Tooth Colored Filling Materials after Bleaching.

    Science.gov (United States)

    Irawan, Bryant Anthony; Irawan, Stacey Natalie; Masudi, Sam'an Malik; Sukminingrum, Ninin; Alam, Mohammad Khursheed

    2015-01-01

    This study aims to evaluate the effects of vital tooth bleaching with carbamide peroxide home bleaching and in-office bleaching on the color stability and 3D surface profile of dental restorative filling materials. Thirty discs (n = 30) measure 6 mm in diameter and 2 mm thick for each of three restorative materials. These are nanofilled composite Filtek Z350 XT, the submicron composite Estelite Σ Quick, and nanofilled glass ionomer Ketac N100 nanoionomer and were fabricated in shade A2. Each group was further divided into three subgroups (n = 10): subgroup A (Opalescence PF), subgroup B (Opalescence Boost in-office bleaching), and subgroup C (distilled water) serving as control. Samples were bleached according to the manufacturer's instructions for a period of two weeks. The Commission Internationale de L'Eclairage (CIE L(*), a(*), b(*)) system was chosen for image processing, while 3D surface profile was tested with atomic force microscopy (AFM). Statistical analyses were performed with the Mann-Whitney tests and Krusal-Wallis with a P value of ≤ 0.05. The three restorative materials showed significant color changes (ΔE); P ≤ 0.05. In diminishing order, the mean color changes recorded were Estelite Σ (3.82 ± 1.6) > Ketac Nano (2.97 ± 1.2) > Filtek Z350 XT (2.25 ± 1.0). However, none of the tested materials showed statistically significant changes in surface roughness; P > 0.05.

  14. 3D Surface Profile and Color Stability of Tooth Colored Filling Materials after Bleaching

    Directory of Open Access Journals (Sweden)

    Bryant Anthony Irawan

    2015-01-01

    Full Text Available This study aims to evaluate the effects of vital tooth bleaching with carbamide peroxide home bleaching and in-office bleaching on the color stability and 3D surface profile of dental restorative filling materials. Thirty discs (n=30 measure 6 mm in diameter and 2 mm thick for each of three restorative materials. These are nanofilled composite Filtek Z350 XT, the submicron composite Estelite Σ Quick, and nanofilled glass ionomer Ketac N100 nanoionomer and were fabricated in shade A2. Each group was further divided into three subgroups (n=10: subgroup A (Opalescence PF, subgroup B (Opalescence Boost in-office bleaching, and subgroup C (distilled water serving as control. Samples were bleached according to the manufacturer’s instructions for a period of two weeks. The Commission Internationale de L’Eclairage (CIE L*, a*, b* system was chosen for image processing, while 3D surface profile was tested with atomic force microscopy (AFM. Statistical analyses were performed with the Mann-Whitney tests and Krusal-Wallis with a P value of ≤0.05. The three restorative materials showed significant color changes (ΔE; P≤0.05. In diminishing order, the mean color changes recorded were Estelite Σ (3.82 ± 1.6 > Ketac Nano (2.97 ± 1.2 > Filtek Z350 XT (2.25 ± 1.0. However, none of the tested materials showed statistically significant changes in surface roughness; P>0.05.

  15. A variable-resolution optical profile measurement system

    Science.gov (United States)

    Tsai, Tung-Hsien; Fan, Kuang-Chao; Mou, Jong-I.

    2002-02-01

    In this study, a variable-resolution optical measurement system (VROPMS) based on triangulation measurement technology is proposed. The VROPMS optical scanning probe is composed of dual CCD cameras fitted with zoom lenses and a line laser diode projector. A flexible and novel calibration procedure for VROPMS is developed to acquire the system parameters quickly and accurately. The central position of the reflected laser image is calculated using Gaussian function least-squares fitting of the beam intensity. Subpixel resolution can thus be acquired. Experimental calibration results show that the higher the lens magnification, the finer the derived system resolution. The best accuracy at the zoomed focus position is about 0.02 mm. This system can flexibly zoom in or out to measure a 3D object profile in sections according to the approximate surface profile. Varied mesh images taken from different zoom positions by VROPMS can be patched using the image matching technique to reconstruct the entire profile. A human sculpture with a complex surface profile is measured using VROPMS as a practical illustration of the effectiveness of the system.

  16. Measurement System & Calibration report

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Vesth, Allan

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A major part of the sensors has been installed by others (see [1]) the rest of the sensors have been installed by DTU. The results of the measurements, described in this report...

  17. Measurement System & Calibration report

    DEFF Research Database (Denmark)

    Georgieva Yankova, Ginka; Federici, Paolo

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A part of the sensors has been installed by others, the rest of the sensors have been installed by DTU. The results of the measurements, described in this report, are only valid...

  18. Measurement System & Calibration report

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Villanueva, Héctor

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A part of the sensors has been installed by others, the rest of the sensors have been installed by DTU. The results of the measurements, described in this report, are only val...

  19. Health System Measurement Project

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Health System Measurement Project tracks government data on critical U.S. health system indicators. The website presents national trend data as well as detailed...

  20. Radioisotope measurement system

    International Nuclear Information System (INIS)

    Villanueva Ruibal, Jose

    2007-01-01

    A radioisotope measurement system installed at L.M.R. (Ezeiza Atomic Center of CNEA) allows the measurement of nuclear activity from a wide range of radioisotopes. It permits to characterize a broad range of radioisotopes at several activity levels. The measurement hardware as well as the driving software have been developed and constructed at the Dept. of Instrumentation and Control. The work outlines the system's conformation and its operating concept, describes design characteristics, construction and the error treatment, comments assay results and supplies use advices. Measuring tests carried out employing different radionuclides confirmed the system performing satisfactorily and with friendly operation. (author) [es

  1. Electrochemical thermodynamic measurement system

    Science.gov (United States)

    Reynier, Yvan [Meylan, FR; Yazami, Rachid [Los Angeles, CA; Fultz, Brent T [Pasadena, CA

    2009-09-29

    The present invention provides systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and electrochemical energy storage and conversion systems. Systems and methods of the present invention are configured for simultaneously collecting a suite of measurements characterizing a plurality of interconnected electrochemical and thermodynamic parameters relating to the electrode reaction state of advancement, voltage and temperature. Enhanced sensitivity provided by the present methods and systems combined with measurement conditions that reflect thermodynamically stabilized electrode conditions allow very accurate measurement of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and electrochemical systems, such as the energy, power density, current rate and the cycle life of an electrochemical cell.

  2. Dialogue scanning measuring systems

    International Nuclear Information System (INIS)

    Borodyuk, V.P.; Shkundenkov, V.N.

    1985-01-01

    The main developments of scanning measuring systems intended for mass precision processsing of films in nuclear physics problems and in related fields are reviewed. A special attention is paid to the problem of creation of dialogue systems which permit to simlify the development of control computer software

  3. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    We present a simple model of systemic risk and we show that each financial institution's contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...... with the institution's leverage and with its expected loss in the tail of the system's loss distribution. Institutions internalize their externality if they are ‘taxed’ based on their SES. We demonstrate empirically the ability of SES to predict emerging risks during the financial crisis of 2007-2009, in particular...

  4. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Heje Pedersen, Lasse

    We present a simple model of systemic risk and we show that each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...... with the institution’s leverage and with its expected loss in the tail of the system’s loss distribution. Institutions internalize their externality if they are “taxed” based on their SES. We demonstrate empirically the ability of SES to predict emerging risks during the financial crisis of 2007-2009, in particular...

  5. Calorimetric measuring systems

    DEFF Research Database (Denmark)

    Ritchie, Andrew Ewen; Pedersen, John Kim; Blaabjerg, Frede

    2004-01-01

    the system cooling requirement. A common problem is that high-frequency phenomena like proximity effect, skin effect, hysteresis losses, and eddy current losses appear in the systems. These losses are very difficult to treat both theoretically and in practice. It is often difficult to measure the effect...... in the system. If the switching speed can be increased, improvements may be possible (e.g., current ripple in an electrical machine or physical size of passive components may be reduced). On the other hand, increased switching speed may cause additional losses in a power electronic system and increase...

  6. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    2017-01-01

    We present an economic model of systemic risk in which undercapitalization of the financial sector as a whole is assumed to harm the real economy, leading to a systemic risk externality. Each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall...... (SES), that is, its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases in the institution’s leverage and its marginal expected shortfall (MES), that is, its losses in the tail of the system’s loss distribution. We demonstrate empirically the ability...... of components of SES to predict emerging systemic risk during the financial crisis of 2007–2009....

  7. Aerial measuring systems program

    International Nuclear Information System (INIS)

    Jobst, J.E.

    1979-01-01

    EG and G, Inc., has developed for the Department of Energy (DOE) an Aerial Measuring Systems (AMS) program dedicated to environmental research at facilities of interest to DOE, the Nuclear Regulatory Commission (NRC), and other federal agencies. The AMS was orginally created to measure nuclear radiation; the program scope has been broadened dramatically to include a wide variety of remote sensors: multispectral and mapping cameras, optical and infrared multispectral scanners, air-sampling systems, and meteorological sensors. The AMS maintains seven aircraft as survey platforms, both fixed-wind aircraft and helicopters. Photography, scanner imagery, and radiation data are processed in dedicated, modern laboratories and used for a broad range of environmental impact studies. A graphic overview system has been developed for effective presentation of all types of remotely sensed data obtained at a facility of interest

  8. In situ measurement system

    Science.gov (United States)

    Lord, D.E.

    1980-11-24

    A multipurpose in situ underground measurement system comprising a plurality of long electrical resistance elements in the form of rigid reinforcing bars, each having an open loop hairpin configuration of shorter length than the other resistance elements. The resistance elements are arranged in pairs in a unitized structure, and grouted in place in the underground volume. Measurement means are provided for obtaining for each pair the electrical resistance of each element and the difference in electrical resistance of the paired elements, which difference values may be used in analytical methods involving resistance as a function of temperature. A scanner means sequentially connects the resistance-measuring apparatus to each individual pair of elements. A source of heating current is also selectively connectable for heating the elements to an initial predetermined temperature prior to electrical resistance measurements when used as an anemometer.

  9. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Heje Pedersen, Lasse

    We present a simple model of systemic risk and we show that each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall (SES), i.e., its propensity to be undercapitalized when the system as a whole is undercapitalized. SES increases...... with the institution’s leverage and with its expected loss in the tail of the system’s loss distribution. Institutions internalize their externality if they are “taxed” based on their SES. We demonstrate empirically the ability of SES to predict emerging risks during the financial crisis of 2007-2009, in particular......, (i) the outcome of stress tests performed by regulators; (ii) the decline in equity valuations of large financial firms in the crisis; and, (iii) the widening of their credit default swap spreads....

  10. Fabrication of Micro-Optics Elements with Arbitrary Surface Profiles Based on One-Step Maskless Grayscale Lithography

    Directory of Open Access Journals (Sweden)

    Qinyuan Deng

    2017-10-01

    Full Text Available A maskless lithography method to realize the rapid and cost-effective fabrication of micro-optics elements with arbitrary surface profiles is reported. A digital micro-mirror device (DMD is applied to flexibly modulate that the exposure dose according to the surface profile of the structure to be fabricated. Due to the fact that not only the relationship between the grayscale levels of the DMD and the exposure dose on the surface of the photoresist, but also the dependence of the exposure depth on the exposure dose, deviate from a linear relationship arising from the DMD and photoresist, respectively, and cannot be systemically eliminated, complicated fabrication art and large fabrication error will results. A method of compensating the two nonlinear effects is proposed that can be used to accurately design the digital grayscale mask and ensure a precise control of the surface profile of the structure to be fabricated. To testify to the reliability of this approach, several typical array elements with a spherical surface, aspherical surface, and conic surface have been fabricated and tested. The root-mean-square (RMS between the test and design value of the surface height is about 0.1 μm. The proposed method of compensating the nonlinear effect in maskless lithography can be directly used to control the grayscale levels of the DMD for fabricating the structure with an arbitrary surface profile.

  11. Microgravity Acceleration Measurement System

    Science.gov (United States)

    Foster, William

    2009-01-01

    Microgravity Acceleration Measurement System (MAMS) is an ongoing study of the small forces (vibrations and accelerations) on the ISS that result from the operation of hardware, crew activities, as well as dockings and maneuvering. Results will be used to generalize the types of vibrations affecting vibration-sensitive experiments. Investigators seek to better understand the vibration environment on the space station to enable future research.

  12. Enterprise performance measurement systems

    Directory of Open Access Journals (Sweden)

    Milija Bogavac

    2014-10-01

    Full Text Available Performance measurement systems are an extremely important part of the control and management actions, because in this way a company can determine its business potential, its market power, potential and current level of business efficiency. The significance of measurement consists in influencing the relationship between the results of reproduction (total volume of production, value of production, total revenue and profit and investments to achieve these results (factors of production spending and hiring capital in order to achieve the highest possible quality of the economy. (The relationship between the results of reproduction and investment to achieve them quantitatively determines economic success as the quality of the economy. Measuring performance allows the identification of the economic resources the company has, so looking at the key factors that affect its performance can help to determine the appropriate course of action.

  13. Radon integral measurement system

    International Nuclear Information System (INIS)

    Garcia H, J.M.

    1994-01-01

    The Radon Integral Measurement System (SMIR) is a device designed specially to detect, to count and to store the data of the acquisition of alpha particles emitted by Radon-222 coming from the underground. The system includes a detection chamber, a radiation detector, a digital system with bateries backup and an auxiliary photovoltaic cell. A personal computer fixes the mode in which the system works, transmitting the commands to the system by the serial port. The heart of the system is a microprocesor working with interrupts by hardware. Every external device to the microprocessor sends his own interrupt request and the microprocessor handles the interrupts with a defined priority. The system uses a real time clock, compatible with the microprocessor, to take care of the real timing and date of the acquisition. A non volatile RAM is used to store data of two bytes every 15 minutes along 41 days as a maximum. After the setting up to the system by the computer, it can operate in stand alone way for up 41 days in the working place without the lose of any data. If the memory is full the next data will be written in the first locations of the memory. The memory is divided in pages corresponding every one of this to a different day of the acquisition. The counting time for every acquisition can be programmed by the user from 15 minutes to 65535 minutes but it is recommended to use a small time not to reach the limit of 65535 counts in every acquisition period. We can take information of the system without affecting the acquisition process in the field by using a lap top computer, then the information can be stored in a file. There is a program in the computer that can show the information in a table of values or in a bar graph. (Author)

  14. Blade Vibration Measurement System

    Science.gov (United States)

    Platt, Michael J.

    2014-01-01

    The Phase I project successfully demonstrated that an advanced noncontacting stress measurement system (NSMS) could improve classification of blade vibration response in terms of mistuning and closely spaced modes. The Phase II work confirmed the microwave sensor design process, modified the sensor so it is compatible as an upgrade to existing NSMS, and improved and finalized the NSMS software. The result will be stand-alone radar/tip timing radar signal conditioning for current conventional NSMS users (as an upgrade) and new users. The hybrid system will use frequency data and relative mode vibration levels from the radar sensor to provide substantially superior capabilities over current blade-vibration measurement technology. This frequency data, coupled with a reduced number of tip timing probes, will result in a system capable of detecting complex blade vibrations that would confound traditional NSMS systems. The hardware and software package was validated on a compressor rig at Mechanical Solutions, Inc. (MSI). Finally, the hybrid radar/tip timing NSMS software package and associated sensor hardware will be installed for use in the NASA Glenn spin pit test facility.

  15. Carbon nanotube oscillator surface profiling device and method of use

    Science.gov (United States)

    Popescu, Adrian [Tampa, FL; Woods, Lilia M [Tampa, FL; Bondarev, Igor V [Fuquay Varina, NC

    2011-11-15

    The proposed device is based on a carbon nanotube oscillator consisting of a finite length outer stationary nanotube and a finite length inner oscillating nanotube. Its main function is to measure changes in the characteristics of the motion of the carbon nanotube oscillating near a sample surface, and profile the roughness of this surface. The device operates in a non-contact mode, thus it can be virtually non-wear and non-fatigued system. It is an alternative to the existing atomic force microscope (AFM) tips used to scan surfaces to determine their roughness.

  16. Systems Measures of Water Distribution System Resilience

    Energy Technology Data Exchange (ETDEWEB)

    Klise, Katherine A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Murray, Regan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Walker, La Tonya Nicole [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Resilience is a concept that is being used increasingly to refer to the capacity of infrastructure systems to be prepared for and able to respond effectively and rapidly to hazardous events. In Section 2 of this report, drinking water hazards, resilience literature, and available resilience tools are presented. Broader definitions, attributes and methods for measuring resilience are presented in Section 3. In Section 4, quantitative systems performance measures for water distribution systems are presented. Finally, in Section 5, the performance measures and their relevance to measuring the resilience of water systems to hazards is discussed along with needed improvements to water distribution system modeling tools.

  17. Measuring name system health

    NARCIS (Netherlands)

    Casalicchio, Emiliano; Caselli, Marco; Coletta, Alessio; Di Blasi, Salvatore; Fovino, Igor Nai; Butts, Jonathan; Shenoi, Sujeet

    2012-01-01

    Modern critical infrastructure assets are exposed to security threats arising from their use of IP networks and the Domain Name System (DNS). This paper focuses on the health of DNS. Indeed, due to the increased reliance on the Internet, the degradation of DNS could have significant consequences for

  18. Calibrating system errors of large scale three-dimensional profile measurement instruments by subaperture stitching method.

    Science.gov (United States)

    Dong, Zhichao; Cheng, Haobo; Feng, Yunpeng; Su, Jingshi; Wu, Hengyu; Tam, Hon-Yuen

    2015-07-01

    This study presents a subaperture stitching method to calibrate system errors of several ∼2  m large scale 3D profile measurement instruments (PMIs). The calibration process was carried out by measuring a Φ460  mm standard flat sample multiple times at different sites of the PMI with a length gauge; then the subaperture data were stitched together using a sequential or simultaneous stitching algorithm that minimizes the inconsistency (i.e., difference) of the discrete data in the overlapped areas. The system error can be used to compensate the measurement results of not only large flats, but also spheres and aspheres. The feasibility of the calibration was validated by measuring a Φ1070  mm aspheric mirror, which can raise the measurement accuracy of PMIs and provide more reliable 3D surface profiles for guiding grinding, lapping, and even initial polishing processes.

  19. Measurement System and Calibration report

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Yordanova, Ginka

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A major part of the sensors has been installed by others (see [1]) the rest of the sensors have been installed by DTU. The results of the measurements, described in this report...

  20. Measurement System and Calibration report

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Villanueva, Héctor

    This Measurement System & Calibration report is describing DTU’s measurement system installed at a specific wind turbine. A major part of the sensors has been installed by others (see [1]) the rest of the sensors have been installed by DTU. The results of the measurements, described in this repor...

  1. Computer systems performance measurement techniques.

    Science.gov (United States)

    1971-06-01

    Computer system performance measurement techniques, tools, and approaches are presented as a foundation for future recommendations regarding the instrumentation of the ARTS ATC data processing subsystem for purposes of measurement and evaluation.

  2. A Portable Stiffness Measurement System

    Directory of Open Access Journals (Sweden)

    Onejae Sul

    2017-11-01

    Full Text Available A new stiffness measurement method is proposed that utilizes the lateral deformation profile of an object under indentation. The system consists of a force measurement module between a pair of equidistant touch sensing modules. Unique feature of the method is that by adjusting the touch module separation, indenter protrusion, and spring constant of the force sensing module, one can choose a desired sensing range for the force module. This feature helps to enhance the stiffness differentiation between objects of similar hardness and avoids measurement saturation. We devised a portable measurement system based on the method, and tested its performance with several materials including polymer foams and human skin.

  3. Facilities projects performance measurement system

    International Nuclear Information System (INIS)

    Erben, J.F.

    1979-01-01

    The two DOE-owned facilities at Hanford, the Fuels and Materials Examination Facility (FMEF), and the Fusion Materials Irradiation Test Facility (FMIT), are described. The performance measurement systems used at these two facilities are next described

  4. Retention Measures and Reporting Systems

    National Research Council Canada - National Science Library

    Ropp, Gary

    2003-01-01

    ...) and performed by the Navy Personnel Research and Development Center (NPRDC) to: (1) review current retention measures in use in the Navy, as well as the system used to distribute retention statistics, and (2...

  5. Error in Radar-Derived Soil Moisture due to Roughness Parameterization: An Analysis Based on Synthetical Surface Profiles

    Directory of Open Access Journals (Sweden)

    Bernard De Baets

    2009-02-01

    Full Text Available In the past decades, many studies on soil moisture retrieval from SAR demonstrated a poor correlation between the top layer soil moisture content and observed backscatter coefficients, which mainly has been attributed to difficulties involved in the parameterization of surface roughness. The present paper describes a theoretical study, performed on synthetical surface profiles, which investigates how errors on roughness parameters are introduced by standard measurement techniques, and how they will propagate through the commonly used Integral Equation Model (IEM into a corresponding soil moisture retrieval error for some of the currently most used SAR configurations. Key aspects influencing the error on the roughness parameterization and consequently on soil moisture retrieval are: the length of the surface profile, the number of profile measurements, the horizontal and vertical accuracy of profile measurements and the removal of trends along profiles. Moreover, it is found that soil moisture retrieval with C-band configuration generally is less sensitive to inaccuracies in roughness parameterization than retrieval with L-band configuration.

  6. Endovascular blood flow measurement system

    Science.gov (United States)

    Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Krivoshapkin, A. L.; Orlov, K. Yu

    2016-06-01

    In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity-pressure” and “flow rate-energy flow rate” diagrams as important characteristics of the blood flow. The measurement system presented here can be used as an additional instrument in neurosurgery for assessment and monitoring of the operation procedure. Clinical data obtained with the system are used for construction of mathematical models and patient-specific simulations. The monitoring of the blood flow parameters during endovascular interventions was approved by the Ethics Committee at the Meshalkin Novosibirsk Research Institute of Circulation Pathology and included in certain surgical protocols for pre-, intra- and postoperative examinations.

  7. Mass properties measurement system dynamics

    Science.gov (United States)

    Doty, Keith L.

    1993-01-01

    The MPMS mechanism possess two revolute degrees-of-freedom and allows the user to measure the mass, center of gravity, and the inertia tensor of an unknown mass. The dynamics of the Mass Properties Measurement System (MPMS) from the Lagrangian approach to illustrate the dependency of the motion on the unknown parameters.

  8. Acoustic building infiltration measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Muehleisen, Ralph T.; Raman, Ganesh

    2018-04-10

    Systems and methods of detecting and identifying a leak from a container or building. Acoustic pressure and velocity are measured. Acoustic properties are acquired from the measured values. The acoustic properties are converted to infiltration/leakage information. Nearfield Acoustic Holography (NAH) may be one method to detect the leakages from a container by locating the noise sources.

  9. Carbon Nanotube Oscillator Surface Profiling Device and Method of Use

    Science.gov (United States)

    2011-11-15

    system. The carbon nanotube oscillator in accor- dance with the present invention can achieve in-plane reso- lution -1 nm as compared to 20-30 nm in...following phenomenologi - cal expression: (13) where m is the mass of the moving tube and y is the appro- priate friction coefficient. E>(z) is the

  10. Nuclear systems of level measurement

    International Nuclear Information System (INIS)

    Lara, A.J.; Cabrera, M.J.

    1992-01-01

    In the industry there are processes in which is necessary to maintain the products level controlled which are handled for their transformation. The majority of such processes and by the operation conditions, they do not admit measure systems of level of invasive type then the application of nuclear techniques for level measurement results a big aid in these cases, since all the system installation is situated beyond frontiers of vessels that contain the product for measuring. In the Department of Nuclear Technology Applications of Mexican Petroleum Institute was developed a level measurement system by gamma rays transmission which operates in the Low Density Polyethylene plant of Petrochemical Complex Escolin at Poza Rica, Veracruz, Mexico. (Author)

  11. Aerial measuring system in Japan.

    Science.gov (United States)

    Lyons, Craig; Colton, David

    2012-05-01

    The U.S. Department of Energy/National Nuclear Security Administration's (DOE/NNSA) Aerial Measuring System (AMS) deployed personnel and equipment to partner with the U.S. Forces in Japan (USFJ) to conduct multiple aerial radiological surveys. These were the first and most comprehensive sources of actionable information for U.S. interests in Japan and provided early confirmation to the Government of Japan as to the extent of the release from the Fukushima Daiichi Nuclear Power Plant. Many challenges were overcome quickly during the first 48 h, including installation and operation of Aerial Measuring System equipment on multiple USFJ aircraft, flying over difficult terrain, and flying with USFJ pilots who were unfamiliar with the Aerial Measuring System flight patterns. These factors combined to make for a programmatically unanticipated situation. In addition to the challenges of multiple and ongoing releases, integration with the Japanese government to provide valid aerial radiological survey products that both military and civilian customers could use to make informed decisions was extremely complicated. The Aerial Measuring System Fukushima response provided insight into addressing these challenges and gave way to an opportunity for the expansion of the Aerial Measuring System's mission beyond the borders of the U.S.

  12. Tracer airflow measurement system (TRAMS)

    Science.gov (United States)

    Wang, Duo [Albany, CA

    2007-04-24

    A method and apparatus for measuring fluid flow in a duct is disclosed. The invention uses a novel high velocity tracer injector system, an optional insertable folding mixing fan for homogenizing the tracer within the duct bulk fluid flow, and a perforated hose sampling system. A preferred embodiment uses CO.sub.2 as a tracer gas for measuring air flow in commercial and/or residential ducts. In extant commercial buildings, ducts not readily accessible by hanging ceilings may be drilled with readily plugged small diameter holes to allow for injection, optional mixing where desired using a novel insertable foldable mixing fan, and sampling hose.

  13. Fluid measurement and characterisation system

    OpenAIRE

    Baldi Coll, Antonio; Sacristán Riquelme, Jorge; García-Cantón, Jesús

    2010-01-01

    [EN] The invention relates to a system for measuring parameters of a liquid being stirred. The invention consists of a system comprising a magnetic stirrer and a read unit that communicates wirelessly with wireless sensors positioned next to the magnetic stirring rod. In this way, it is possible to stir the liquid and monitor the parameters of the liquid with a single device and without using electrical wiring in order to access the interior of the container housing the liquid to be ...

  14. Ground-truth measurement systems

    Science.gov (United States)

    Serafin, R.; Seliga, T. A.; Lhermitte, R. M.; Nystuen, J. A.; Cherry, S.; Bringi, V. N.; Blackmer, R.; Heymsfield, G. M.

    1981-01-01

    Ground-truth measurements of precipitation and related weather events are an essential component of any satellite system designed for monitoring rainfall from space. Such measurements are required for testing, evaluation, and operations; they provide detailed information on the actual weather events, which can then be compared with satellite observations intended to provide both quantitative and qualitative information about them. Also, very comprehensive ground-truth observations should lead to a better understanding of precipitation fields and their relationships to satellite data. This process serves two very important functions: (a) aiding in the development and interpretation of schemes of analyzing satellite data, and (b) providing a continuing method for verifying satellite measurements.

  15. N-16 power measuring system

    International Nuclear Information System (INIS)

    Graham, K.F.

    1977-12-01

    The thermal power output of a reactor can be measured by monitoring the total amount of heat removed from the reactor core per unit of time. Other methods of measuring the power level indirectly, as for instance, utilizing the neutron flux outside the core, have the disadvantage of heavy influences on the accuracy due to changes of the neutron flux distribution in the core caused by control rod operation and xenon buildup effects. Heat balance (ΔT) measurements in the primary loop are used to measure reactor power but require hot leg RTD bypass loops and have slow time response. An N-16 system has been developed which shows several advantages over the ΔT and excore power measurements. The Nitrogen-16 (N-16) activity in the primary coolant water of a PWR has long been considered as a possible parameter for continuous measurement of reactor power level. The N-16 activity is formed by fast neutron activation of Oxygen-16 contained in the water. Activation results from a threshold reaction requiring >10 MeV neutrons. It can be shown that the N-16 content in the coolant is a direct measure of the integrated fast flux throughout the core and is thereby a direct measure of the fission rate and total power generated. Decay of the N-16 produces 6 MeV gamma rays which readily penetrate the wall of the high pressure piping. Thus, the N-16 concentration in the coolant can easily be monitored by measuring the gamma radiation outside the pipe--for instance, at the hot leg of the coolant loop. The N-16 power monitor is calibrated against secondary heat balance measurements, since these are assumed to give the most accurate information on the absolute thermal power level

  16. In-situ measurement system

    Science.gov (United States)

    Lord, David E.

    1983-01-01

    A multipurpose in situ underground measurement system comprising a plurality of long electrical resistance elements in the form of rigid reinforcing bars, each having an open loop "hairpin" configuration of shorter length than the other resistance elements. The resistance elements are arranged in pairs in a unitized structure, and grouted in place in the underground volume. The electrical resistance of each element and the difference in electrical resistance of the paired elements are obtained, which difference values may be used in analytical methods involving resistance as a function of temperature. A scanner sequentially connects the resistance-measuring apparatus to each individual pair of elements. A source of heating current is also selectively connectable for heating the elements to an initial predetermined temperature prior to electrical resistance measurements when used as an anemometer.

  17. Integral measurement system for radon

    International Nuclear Information System (INIS)

    Garcia H, J.M.; Pena E, R.

    1996-01-01

    The Integral measurement system for Radon is an equipment to detect, counting and storage data of alpha particles produced by Radon 222 which is emanated through the terrestrial peel surface. This equipment was designed in the Special Designs Department of the National Institute of Nuclear Research. It supplies information about the behavior at long time (41 days) on each type of alpha radiation that is present into the environment as well as into the terrestrial peel. The program is formed by an User program, where it is possible to determine the operation parameters of a portable probe that contains, a semiconductor detector, a microprocessor as a control central unit, a real time clock and calendar to determine the occurred events chronology, a non-volatile memory device for storage the acquired data and an interface to establish the serial communications with other personal computers. (Author)

  18. Predicting the impact of vegetations in open channels with different distributaries' operations on water surface profile using artificial neural networks

    International Nuclear Information System (INIS)

    Abdeen, Mostafa A. M.

    2008-01-01

    Most of the open water irrigation channels in Egypt suffer from the infestation of aquatic weeds, especially the submerged ones that cause numerous hydraulic problems for the open channels themselves and their water distributaries such as increasing water losses, obstructing water flow, and reducing channels' water distribution efficiencies. Accurate simulation and prediction of flow behavior in such channels is very essential for water distribution decision makers. Artificial neural networks (ANN) have proven to be very successful in the simulation of several physical phenomena, in general, and in the water research field in particular. Therefore, the current study aims towards introducing the utilization of ANN in simulating the impact of vegetation in main open channel, which supplies water to different distributaries, on the water surface profile in this main channel. Specifically, the study, presented in the current paper utilizes ANN technique for the development of various models to simulate the impact of different submerged weeds' densities, different flow discharges, and different distributaries operation scheduling on the water surface profile in an experimental main open channel that supplies water to different distributaries. In the investigated experiment, the submerged weeds were simulated as branched flexible elements. The investigated experiment was considered as an example for implementing the same methodology and technique in a real open channel system. The results showed that the ANN technique is very successful in simulating the flow behavior of the pre-mentioned open channel experiment with the existence of the submerged weeds. In addition, the developed ANN models were capable of predicting the open channel flow behavior in all the submerged weeds' cases that were considered in the ANN development process

  19. True mean rate measuring system

    International Nuclear Information System (INIS)

    Eichenlaub, D.P.

    1980-01-01

    A digital radiation-monitoring system for nuclear power plants uses digital and microprocessor circuitry to enable rapid processing of pulse information from remote radiation monitors. The pulse rates are analyzed to determine whether new pulse-rate information is statisticaly the same as that previously received and to determine the best possible averaging time, which can be changed so that the statistical error remains below a specified level while the system response time remains short. Several data modules each process the pulse-rate information from several remote radiation monitors. Each data module accepts pulse data from each radiation monitor and measures the true average or mean pulse rate of events occurring with a Poisson distribution to determine the radiation level. They then develop digital output signals which indciate the respective radiation levels and which can be transmitted via multiplexer circuits for additional processing and display. The data modules can accept signals from remote control stations or computer stations via the multiplexer circuit to change operating thresholds and alarm levels in their memories. A check module scans the various data modules to determine whether the output signals are valid. It also acts as a redundant data module and will automatically replace an inoperative unit. (DN)

  20. Measurement System and Calibration report

    DEFF Research Database (Denmark)

    Vesth, Allan; Kock, Carsten Weber

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...

  1. Surface profiling of normally responding and nonreleasing basophils by flow cytometry

    DEFF Research Database (Denmark)

    Kistrup, Kasper; Poulsen, Lars Kærgaard; Jensen, Bettina Margrethe

    a maximum release blood mononuclear cells were purified by density centrifugation and using flow cytometry, basophils, defined as FceRIa+CD3-CD14-CD19-CD56-,were analysed for surface expression of relevant markers. All samples were compensated and analysed in logicle display. All gates......c, C3aR, C5aR CCR3, FPR1, ST2, CRTH2 on anti-IgE respondsive and nonreleasing basophils by flow cytometry, thereby generating a surface profile of the two phenotypes. Methods Fresh buffy coat blood (

  2. Brush seal performance measurement system

    OpenAIRE

    Aksoy, Serdar; Akşit, Mahmut Faruk; Aksit, Mahmut Faruk; Duran, Ertuğrul Tolga; Duran, Ertugrul Tolga

    2009-01-01

    Brush seals are rapidly replacing conventional labyrinth seals in turbomachinery applications. Upon pressure application, seal stiffness increases drastically due to frictional bristle interlocking. Operating stiffness is critical to determine seal wear life. Typically, seal stiffness is measured by pressing a curved shoe to brush bore. The static-unpressurized measurement is extrapolated to pressurized and high speed operating conditions. This work presents a seal stiffness measurement syste...

  3. Measurement System and Calibration report

    DEFF Research Database (Denmark)

    Vesth, Allan; Kock, Carsten Weber

    The report describes Load measurements carried out on a given wind turbine. The aim of the measurement program regarding the loads on the turbine is to verify the basic characteristics of the wind turbine and loads on the blades, the rotor and the tower, using [Ref 1], [Ref2] and [Ref 3]. Regarding...

  4. Near Field Antenna Measurement System.

    Science.gov (United States)

    1978-01-11

    training session in mid January to become fully familia r with the System 1000 hardware and Real -Time Executive software. No probl ems have been...07703 Wright-Patterson Air Force Base Deyton, OH 1451133 ~Thief 1Naval Ship Systeme Command NASA Scientific & Tech 2 Departsien~ of the Navy Information

  5. HTGR Measurements and Instrumentation Systems

    International Nuclear Information System (INIS)

    Ball, Sydney J.; Holcomb, David Eugene; Cetiner, Mustafa Sacit

    2012-01-01

    This report provides an integrated overview of measurements and instrumentation for near-term future high-temperature gas-cooled reactors (HTGRs). Instrumentation technology has undergone revolutionary improvements since the last HTGR was constructed in the United States. This report briefly describes the measurement and communications needs of HTGRs for normal operations, maintenance and inspection, fuel fabrication, and accident response. The report includes a description of modern communications technologies and also provides a potential instrumentation communications architecture designed for deployment at an HTGR. A principal focus for the report is describing new and emerging measurement technologies with high potential to improve operations, maintenance, and accident response for the next generation of HTGRs, known as modular HTGRs, which are designed with passive safety features. Special focus is devoted toward describing the failure modes of the measurement technologies and assessing the technology maturity.

  6. In Vitro assessment of dentin erosion after immersion in acidic beverages: surface profile analysis and energy-dispersive X-ray fluorescence spectrometry study

    OpenAIRE

    Caneppele, Taciana Marco Ferraz; Jeronymo, Raffaela Di Iorio; Di Nicoló, Rebeca; Araújo, Maria Amélia Máximo de; Soares, Luís Eduardo Silva

    2012-01-01

    The aim of this study was to investigate the effects of some acidic drinks on dentin erosion, using methods of surface profile (SP) analysis and energy-dispersive X-ray fluorescence spectrometry (EDXRF). One hundred standardized dentin slabs obtained from bovine incisor roots were used. Dentin slabs measuring 5x5 mm were ground flat, polished and half of each specimen surface was protected with nail polish. For 60 min, the dentin surfaces were immersed in 50 mL of 5 different drinks (Gatorade...

  7. Advanced compact laser scanning system enhancements for gear and thread measurements. Final CRADA report

    Energy Technology Data Exchange (ETDEWEB)

    McKeethan, W.M.; Maxey, L.C.; Bernacki, B.E. [Lockheed Martin Energy Systems, Inc., Oak Ridge, TN (United States); Castore, G. [Apeiron, Inc., Bloomington, MN (United States)

    1997-04-04

    The measurement, or metrology, of physical objects is a fundamental requirement for industrial progress. Dimensional measurement capability lies at the heart of ones ability to produce objects within the required technical specifications. Dimensional metrology systems are presently dominated by touch-probe technologies, which are mature and reliable. Due to the intricate geometries required in certain fields of manufacturing, these contract probes cannot be physically brought in proximity to the measurement surface, or lack sufficient lateral resolution to satisfactorily determine the surface profile, which can occur in the measurement of gears, splines and thread. Optical probes are viable candidates to supplement the contact probes, since light can be focused to less than one micron (40 microinches), no contact occurs that can mar highly finished surfaces, and no probes must be replaced due to wear. However, optical probes typically excel only on one type of surface: mirror-like or diffuse, and the optical stylus itself is oftentimes not as compact as its contact probe counterpart. Apeiron, Inc. has pioneered the use of optical non-contact sensors to measure machined parts, especially threads, gears and splines. The Oak Ridge Metrology Center at Oak Ridge Y-12 Plant are world-class experts in dimensional metrology. The goal of this CRADA is to tap the expertise in Oak Ridge to evaluate Apeiron`s platform, and to suggest new or novel methods of optical surface sensing, if appropriate.

  8. Introduction to control system performance measurements

    CERN Document Server

    Garner, K C

    1968-01-01

    Introduction to Control System Performance Measurements presents the methods of dynamic measurements, specifically as they apply to control system and component testing. This book provides an introduction to the concepts of statistical measurement methods.Organized into nine chapters, this book begins with an overview of the applications of automatic control systems that pervade almost every area of activity ranging from servomechanisms to electrical power distribution networks. This text then discusses the common measurement transducer functions. Other chapters consider the basic wave

  9. Measures of Autonomic Nervous System

    Science.gov (United States)

    2011-04-01

    Gastro- intestinal Pupillary Response Respiratory Salivary Amylase Vascular Manipulative Body-Based/ Tension-Release Practices Trauma...Physiological Activities ANS Physiological Activities Cardiac Pupillary Response Catecholamines Respiration Cortisol Salivary Amylase Galvanic Skin...results reported  Cronbach alpha exceeding 0.70 Validity was assessed by the tool’s ability to quantify the data to be measured and was

  10. SQUID-based measuring systems

    Indian Academy of Sciences (India)

    field produced by a given two-dimensional current density distribution is inverted using the Fourier transform technique. Keywords ... Superconducting quantum interference devices (SQUIDs) are the most sensitive detectors for measurement of ... omagnetic prospecting, detection of gravity waves etc. Judging the importance ...

  11. SQUID-based measuring systems

    Indian Academy of Sciences (India)

    cryostats and precision X-Y table with stepper motor for accurate positioning for the re- construction of electrical current density from measured spatial variation of magnetic field. A planar gradiometric DC SQUID sensor for NDE has been designed and developed to be used in relatively unshielded environment and is shown ...

  12. Absolute calibration in vivo measurement systems

    International Nuclear Information System (INIS)

    Kruchten, D.A.; Hickman, D.P.

    1991-02-01

    Lawrence Livermore National Laboratory (LLNL) is currently investigating a new method for obtaining absolute calibration factors for radiation measurement systems used to measure internally deposited radionuclides in vivo. Absolute calibration of in vivo measurement systems will eliminate the need to generate a series of human surrogate structures (i.e., phantoms) for calibrating in vivo measurement systems. The absolute calibration of in vivo measurement systems utilizes magnetic resonance imaging (MRI) to define physiological structure, size, and composition. The MRI image provides a digitized representation of the physiological structure, which allows for any mathematical distribution of radionuclides within the body. Using Monte Carlo transport codes, the emission spectrum from the body is predicted. The in vivo measurement equipment is calibrated using the Monte Carlo code and adjusting for the intrinsic properties of the detection system. The calibration factors are verified using measurements of existing phantoms and previously obtained measurements of human volunteers. 8 refs

  13. Measurement system as a subsystem of the quality management system

    OpenAIRE

    Ľubica Floreková; Ján Terpák; Marcela Čarnogurská

    2006-01-01

    Each measurement system and a control principle must be based on certain facts about the system behaviour (what), operation (how) and structure (why). Each system is distributed into subsystems that provide an input for the next subsystem. For each system, start is important the begin, that means system characteristics, collecting of data, its hierarchy and the processes distribution.A measurement system (based on the chapter 8 of the standard ISO 9001:2000 Quality management system, requirem...

  14. A shielded measurement system for irradiated nuclear fuel measurements

    Energy Technology Data Exchange (ETDEWEB)

    Mosby, W.R.; Aumeier, S.E.; Klann, R.T.

    1999-07-01

    The US Department of Energy (DOE) is driving a transition toward dry storage of irradiated nuclear fuel (INF), toward characterization of INF for final disposition, and toward resumption of measurement-based material control and accountability (MC and A) efforts for INF. For these reasons, the ability to efficiently acquire radiological measurements of INF in a dry environment is important. The DOE has recently developed a guidance document proposing MC and A requirements for INF. The intent of this document is to encourage the direct measurement of INF on inventory within DOE. The guidance document reinforces and clarifies existing material safeguards requirements as they pertain to INF. Validation of nuclear material contents of non-self-protecting INF must be accomplished by direct measurement, application of validated burnup codes using qualified initial fissile content, burnup data, and age or by other valid means. The fuel units must remain intact with readable identification numbers. INF may be subject to periodic inventories with visual item accountability checks. Quantitative measurements may provide greater assurance of the integrity of INF inventories at a lower cost and with less personnel exposure than visual item accountability checks. Currently, several different approaches are used to measure the radiological attributes of INF. Although these systems are useful for a wide variety of applications, there is currently no relatively inexpensive measurement system that is readily deployable for INF measurements for materials located in dry storage. The authors present the conceptual design of a shielded measurement system (SMS) that could be used for this purpose. The SMS consists of a shielded enclosure designed to house a collection of measurement systems to allow measurements on spent fuel outside of a hot cell. The phase 1 SMS will contain {sup 3}He detectors and ionization chambers to allow for gross neutron and gamma-ray measurements. The phase 2

  15. Integrated multi-parameter flow measurement system

    NARCIS (Netherlands)

    Lötters, Joost Conrad; van der Wouden, E.J.; Groenesteijn, Jarno; Sparreboom, Wouter; Lammerink, Theodorus S.J.; Wiegerink, Remco J.

    2014-01-01

    We have designed and realized an integrated multi-parameter flow measurement system, consisting of an integrated Coriolis and thermal flow sensor, and a pressure sensor. The integrated system enables on-chip measurement, analysis and determination of flow and several physical properties of both

  16. Qualification of a Voltammetry Measurement System

    OpenAIRE

    Scholz, Sunna

    2014-01-01

    The voltammetry measurement system consisting of a potentiostat μStat 200, electrode strips and accessories has been scrutinized, following the four phases of instrument qualification. These are design qualification, installation qualification, operational qualification and performance qualification in succeeding order. As design qualification operational specifications of the voltammetry measurement system have been collected. These were the innovative technique of screen printing electro...

  17. Electronic instrumentation system for pulsed neutron measurements

    International Nuclear Information System (INIS)

    Burda, J.; Igielski, A.; Kowalik, W.

    1982-01-01

    An essential point of pulsed neutron measurement of thermal neutron parameters for different materials is the registration of the thermal neutron die-away curve after a fast neutron bursts have been injected into the system. An electronic instrumentation system which is successfully applied for pulsed neutron measurements is presented. An important part of the system is the control unit which has been designed and built in the Laboratory of Neutron Parameters of Materials. (author)

  18. Turbine gas temperature measurement and control system

    Science.gov (United States)

    Webb, W. L.

    1973-01-01

    A fluidic Turbine Inlet Gas Temperature (TIGIT) Measurement and Control System was developed for use on a Pratt and Whitney Aircraft J58 engine. Based on engine operating requirements, criteria for high temperature materials selection, system design, and system performance were established. To minimize development and operational risk, the TIGT control system was designed to interface with an existing Exhaust Gas Temperature (EGT) Trim System and thereby modulate steady-state fuel flow to maintain a desired TIGT level. Extensive component and system testing was conducted including heated (2300F) vibration tests for the fluidic sensor and gas sampling probe, temperature and vibration tests on the system electronics, burner rig testing of the TIGT measurement system, and in excess of 100 hours of system testing on a J58 engine. (Modified author abstract)

  19. Human Characteristics and Measures in Systems Design

    Science.gov (United States)

    2003-01-01

    MEASURES IN SYSTEMS DESIGN 19.2.5 Physiological Factors Human physiology is based on the concept of homeostasis , the natural feedback system that...characteristics of the human components within our "man-made" systems engineering ecosystem . Understanding the strengths and limitations of the human

  20. System Entropy Measurement of Stochastic Partial Differential Systems

    Directory of Open Access Journals (Sweden)

    Bor-Sen Chen

    2016-03-01

    Full Text Available System entropy describes the dispersal of a system’s energy and is an indication of the disorder of a physical system. Several system entropy measurement methods have been developed for dynamic systems. However, most real physical systems are always modeled using stochastic partial differential dynamic equations in the spatio-temporal domain. No efficient method currently exists that can calculate the system entropy of stochastic partial differential systems (SPDSs in consideration of the effects of intrinsic random fluctuation and compartment diffusion. In this study, a novel indirect measurement method is proposed for calculating of system entropy of SPDSs using a Hamilton–Jacobi integral inequality (HJII-constrained optimization method. In other words, we solve a nonlinear HJII-constrained optimization problem for measuring the system entropy of nonlinear stochastic partial differential systems (NSPDSs. To simplify the system entropy measurement of NSPDSs, the global linearization technique and finite difference scheme were employed to approximate the nonlinear stochastic spatial state space system. This allows the nonlinear HJII-constrained optimization problem for the system entropy measurement to be transformed to an equivalent linear matrix inequalities (LMIs-constrained optimization problem, which can be easily solved using the MATLAB LMI-toolbox (MATLAB R2014a, version 8.3. Finally, several examples are presented to illustrate the system entropy measurement of SPDSs.

  1. Entropy Measurement for Biometric Verification Systems.

    Science.gov (United States)

    Lim, Meng-Hui; Yuen, Pong C

    2016-05-01

    Biometric verification systems are designed to accept multiple similar biometric measurements per user due to inherent intrauser variations in the biometric data. This is important to preserve reasonable acceptance rate of genuine queries and the overall feasibility of the recognition system. However, such acceptance of multiple similar measurements decreases the imposter's difficulty of obtaining a system-acceptable measurement, thus resulting in a degraded security level. This deteriorated security needs to be measurable to provide truthful security assurance to the users. Entropy is a standard measure of security. However, the entropy formula is applicable only when there is a single acceptable possibility. In this paper, we develop an entropy-measuring model for biometric systems that accepts multiple similar measurements per user. Based on the idea of guessing entropy, the proposed model quantifies biometric system security in terms of adversarial guessing effort for two practical attacks. Excellent agreement between analytic and experimental simulation-based measurement results on a synthetic and a benchmark face dataset justify the correctness of our model and thus the feasibility of the proposed entropy-measuring approach.

  2. Evaluation of the MADAM waste measurement system

    International Nuclear Information System (INIS)

    Foster, L.A.; Wachter, J.R.; Hagan, R.C.

    1995-01-01

    The Multiple Assay Dual Analysis Measurement (MADAM) system is a combined low-level and transuranic waste assay system. The system integrates commercially available Segmented Gamma Scanner (SGS) capability with a multienergy x-ray and gamma-ray analysis to measure these two waste forms. In addition, the system incorporates a small neutron slab detector to satisfy safeguards concerns and the capability for automated high-resolution gamma-ray analysis for isotope identification. Since delivery of the system to this facility, an evaluation of the waste measurement characteristics of the system has been conducted. A set of specially constructed NIST-traceable standards was fabricated for calibration and evaluation of the low-level waste (LLW) measurement system. The measurement characteristics of the LLW assay system were determined during the evaluation, including detection limits for all isotopes of interest, matrix attenuation effects, and detector response as a function of source position. Based on these studies, several modifications to the existing analysis algorithms have been performed, new correction factors for matrix attenuation have been devised, and measurement error estimates have been calculated and incorporated into the software

  3. INFORMATION SECURITY IN MOBILE MODULAR MEASURING SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. N. Tkhishev

    2017-01-01

    Full Text Available A special aspect of aircraft test is carrying out both flight evaluation and ground operation evaluation in a structure of flying aids and special tools equipment. The specific of flight and sea tests involve metering in offshore zone, which excludes the possibility of fixed geodetically related measuring tools. In this regard, the specific role is acquired by shipbased measurement systems, in particular the mobile modular measuring systems. Information processed in the mobile modular measurement systems is a critical resource having a high level of confidentiality. When carrying out their functions, it should be implemented a proper information control of the mobile modular measurement systems to ensure their protection from the risk of data leakage, modification or loss, i.e. to ensure a certain level of information security. Due to the specific of their application it is difficult to solve the problems of information security in such complexes. The intruder model, the threat model, the security requirements generated for fixed informatization objects are not applicable to mobile systems. It was concluded that the advanced mobile modular measuring systems designed for flight experiments monitoring and control should be created due to necessary information protection measures and means. The article contains a diagram of security requirements formation, starting with the data envelopment analysis and ending with the practical implementation. The information security probabilistic model applied to mobile modular measurement systems is developed. The list of current security threats based on the environment and specific of the mobile measurement system functioning is examined. The probabilistic model of the information security evaluation is given. The problems of vulnerabilities transformation of designed information system into the security targets with the subsequent formation of the functional and trust requirements list are examined.

  4. Photoplethysmographic measurements from central nervous system tissue

    International Nuclear Information System (INIS)

    Phillips, J P; Kyriacou, P A; Chang, S H; Maney, K; George, K J; Langford, R M

    2007-01-01

    A new system for measuring the oxygen saturation of blood within tissue has been developed, for a number of potential patient monitoring applications. This proof of concept project aims to address the unmet need of real-time measurement of oxygen saturation in the central nervous system (CNS) for patients recovering from neurosurgery or trauma, by developing a fibre optic signal acquisition system for internal placement through small apertures. The development and testing of a two-wavelength optical fibre reflectance photoplethysmography (PPG) system is described together with measurements in rats and preliminary results from a clinical trial of the system in patients undergoing neurosurgery. It was found that good quality red and near-infrared PPG signals could be consistently obtained from the rat spinal cord (n=6) and human cerebral cortex (n=4) using the fibre optic probe. These findings justify further development and clinical evaluation of this fibre optic system

  5. Photoplethysmographic measurements from central nervous system tissue

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, J P [Anaesthetic Laboratory, St Bartholomew' s Hospital, London, EC1A 7BE (United Kingdom); Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, London, EC1V 0HB (United Kingdom); Chang, S H [Anaesthetic Laboratory, St Bartholomew' s Hospital, London, EC1A 7BE (United Kingdom); Maney, K [Anaesthetic Laboratory, St Bartholomew' s Hospital, London, EC1A 7BE (United Kingdom); George, K J [Neuroscience Centre, Queen Mary, University of London, E1 0NS (United Kingdom); Langford, R M [Anaesthetic Laboratory, St Bartholomew' s Hospital, London, EC1A 7BE (United Kingdom)

    2007-10-15

    A new system for measuring the oxygen saturation of blood within tissue has been developed, for a number of potential patient monitoring applications. This proof of concept project aims to address the unmet need of real-time measurement of oxygen saturation in the central nervous system (CNS) for patients recovering from neurosurgery or trauma, by developing a fibre optic signal acquisition system for internal placement through small apertures. The development and testing of a two-wavelength optical fibre reflectance photoplethysmography (PPG) system is described together with measurements in rats and preliminary results from a clinical trial of the system in patients undergoing neurosurgery. It was found that good quality red and near-infrared PPG signals could be consistently obtained from the rat spinal cord (n=6) and human cerebral cortex (n=4) using the fibre optic probe. These findings justify further development and clinical evaluation of this fibre optic system.

  6. Computer system performance measurement techniques for ARTS III computer systems.

    Science.gov (United States)

    1973-12-01

    Direct measurement of computer systems is of vital importance in: a) developing an intelligent grasp of the variables which affect overall performance; b)tuning the system for optimum benefit; c)determining under what conditions saturation thresholds...

  7. Joint and weak measurements on qubit systems

    International Nuclear Information System (INIS)

    O'Brien, J.L.; Pryde, G.J.; Bartlett, S.D.; Ralph, T.C.; Wiseman, H.M.; White, A.G.

    2005-01-01

    Full text: Along with the well-known concept of projective measurements, quantum mechanics allows various kinds of generalized measurement operators. Two important examples are: joint measurements on two or more quantum systems that cannot be achieved by local operations (LOCC); and weak measurements that obtain less information about a system than does a projective measurement, but with correspondingly less disturbance. Unlike the result of a strong measurement, the average value of a weak measurement of an observable (its weak value), when followed by projective postselection in a complementary basis, can lie outside the range of eigenvalues. This discrepancy is not observed in analogous classical measurements. Weak values aid the resolution of quantum paradoxes, and can simplify analysis of weakly coupled systems. We use a generalized measurement device to measure the weak value of a photon's polarization in the horizontal/vertical basis (the Stokes operator S1 = |H> weak up to 47, outside the usual range -1 ≤ S1 ≤ 1. Unlike previous observations of weak values, our measurement works by entangling two separate systems, and thus can only be described by quantum theory, not a classical wave theory. Also, we have used a two-qubit joint measurement based on a controlled-NOT gate by which certain twoqubit unentangled states can be more reliably distinguished than by using LOCC. We quantify this using a payoff function, for which the optimal LOCC measurement attains 2/3, and our experimental measurement attains 0.72 ± 0.02, close to the global optimum of 3/4. (author)

  8. Measurement and evaluation systems for NPP commissioning

    International Nuclear Information System (INIS)

    Elko, Marek

    2006-01-01

    Standard core monitoring and information systems are designed with an emphasis on normal operation of nuclear power plant. Their purpose is to provide necessary support for reactor operators and other operating personnel during the fuel cycle. After each fuel reloading, and to the larger extent during the plant commissioning, a variety of start-up tests need to be carried out and evaluated. Sampling periods, accuracy and communication delays of standard systems are not always suitable for test performance and evaluation. For technical and safety reasons, the access to standard monitoring and information systems is very limited. Non-Standard Measurement and Evaluation Systems are highly specialized devices designed with an emphasis on start-up tests performance and evaluation. They are capable of high frequency sampling, processing and communication of hundreds of technological signals with required accuracy and low communication delay. All technological signals needed for the test performance and evaluation are collected from various systems, concentrated in one system and fully accessible to a test leader, a reactor physicist or other users. In addition, Non-Standard Measurement and Evaluation Systems can perform other tasks like data storing and presentation, data distribution to other systems or external computers via network, reactivity calculations, etc. Structure of such systems can vary, but generally it is a mixture of two basic concepts: a mobile system and a stationary system. A basic description of hardware structure and software equipment of Non-Standard Measurement and Evaluation Systems is given in the paper (Authors)

  9. Preparation Measurements and Assessment of Roof Systems

    Science.gov (United States)

    Baláž, Richard; Bagoňa, Miloslav

    2014-11-01

    The Institute of Architectural Engineering at the Civil Engineering Faculty TU of Kosice, in its ongoing research, aims to monitor the physical properties of building envelope structures with emphasis placed on hydrothermal problems, at present. The research focuses on the assembly of equipment in climate chambers with their respective sample envelopes and fenestration systems, which are involved in a measuring experiment. The prime aim is to design a logical and transparent system for gathering, evaluating and storing hydrothermal related data. This contribution further illustrates the embedding system of measurement points in installed samples and the system of monitoring their physical properties over an annual period.

  10. Three-component laser anemometer measurement systems

    Science.gov (United States)

    Goldman, Louis J.

    1991-01-01

    A brief overview of the different laser anemometer (LA) optical designs available is presented. Then, the LA techniques that can be used to design a three-component measurement system for annular geometries are described. Some of the facility design considerations unique to these LA systems are also addressed. Following this, the facilities and the LA systems that were used to successfully measure the three components of velocity in the blading of annular-flow machines are reviewed. Finally, possible LA system enhancements and future research directions are presented.

  11. Analysis of measurement system as the mechatronics system

    Energy Technology Data Exchange (ETDEWEB)

    Giniotis, V [Institute of Geodesy, Vilnius Gediminas Technical University, Vilnius, Lithuania, Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania); Grattan, K T V [School of Engineering and Mathematical Sciences Electrical, Electronic and Information Eng, City University, Northampton Square, London EC1V 0HB (United Kingdom); Rybokas, M [Department of Information Technologies, Vilnius Gediminas Technical University, Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania); Brucas, D, E-mail: gi@ap.vtu.l, E-mail: k.t.v.grattan@city.ac.u, E-mail: MRybokas@gama.l, E-mail: domka@ktv.l, E-mail: vg@ai.vgtu.l [Department of Geodesy and Cadastre, Vilnius Gediminas Technical University, Vilnius, Lithuania Sauletekio al. 11, 10223 Vilnius-40, Lithuania, Fax: 370 5 2744 705 (Lithuania)

    2010-07-01

    The paper deals with the mechatronic arrangement for angle measuring system application. The objects to be measured are the circular raster scales, rotary encoders and coded scales. The task of the measuring system is to determine the bias of angle measuring standard as the circular scale and to use the results for the error correction and accuracy improvement of metal cutting machines, coordinate measuring machines, robots, etc. The technical solutions are given with the application of active materials for smart piezoactuators implemented into the several positions of angular measuring equipment. Mechatronic measuring system is analysed as complex integrated system and some of its elements can be used as separate units. All these functional elements are described and commented in the paper with the diagrams and graphs of errors and examples of microdisplacement devices using the mechatronic elements.

  12. Analysis of measurement system as the mechatronics system

    International Nuclear Information System (INIS)

    Giniotis, V; Grattan, K T V; Rybokas, M; Brucas, D

    2010-01-01

    The paper deals with the mechatronic arrangement for angle measuring system application. The objects to be measured are the circular raster scales, rotary encoders and coded scales. The task of the measuring system is to determine the bias of angle measuring standard as the circular scale and to use the results for the error correction and accuracy improvement of metal cutting machines, coordinate measuring machines, robots, etc. The technical solutions are given with the application of active materials for smart piezoactuators implemented into the several positions of angular measuring equipment. Mechatronic measuring system is analysed as complex integrated system and some of its elements can be used as separate units. All these functional elements are described and commented in the paper with the diagrams and graphs of errors and examples of microdisplacement devices using the mechatronic elements.

  13. Measurement system as a subsystem of the quality management system

    Directory of Open Access Journals (Sweden)

    Ľubica Floreková

    2006-12-01

    Full Text Available Each measurement system and a control principle must be based on certain facts about the system behaviour (what, operation (how and structure (why. Each system is distributed into subsystems that provide an input for the next subsystem. For each system, start is important the begin, that means system characteristics, collecting of data, its hierarchy and the processes distribution.A measurement system (based on the chapter 8 of the standard ISO 9001:2000 Quality management system, requirements defines the measurement, analysis and improvement for each organization in order to present the products conformity, the quality management system conformity guarantee and for the continuously permanent improvement of effectivity, efficiency and economy of quality management system.

  14. Telemetric measurement system of beehive environment conditions

    Science.gov (United States)

    Walendziuk, Wojciech; Sawicki, Aleksander

    2014-11-01

    This work presents a measurement system of beehive environmental conditions. The purpose of the device is to perform measurements of parameters such as ambient temperature, atmospheric pressure, internal temperature, humidity and sound level. The measured values were transferred to the MySQL database, which is located on an external server, with the use of GPRS protocol. A website presents the measurement data in the form of tables and graphs. The study also shows exemplary results of environmental conditions measurements recorded in the beehive by hour cycle.

  15. Measurement System Characterization in the Presence of Measurement Errors

    Science.gov (United States)

    Commo, Sean A.

    2012-01-01

    In the calibration of a measurement system, data are collected in order to estimate a mathematical model between one or more factors of interest and a response. Ordinary least squares is a method employed to estimate the regression coefficients in the model. The method assumes that the factors are known without error; yet, it is implicitly known that the factors contain some uncertainty. In the literature, this uncertainty is known as measurement error. The measurement error affects both the estimates of the model coefficients and the prediction, or residual, errors. There are some methods, such as orthogonal least squares, that are employed in situations where measurement errors exist, but these methods do not directly incorporate the magnitude of the measurement errors. This research proposes a new method, known as modified least squares, that combines the principles of least squares with knowledge about the measurement errors. This knowledge is expressed in terms of the variance ratio - the ratio of response error variance to measurement error variance.

  16. Distance and Cable Length Measurement System

    Science.gov (United States)

    Hernández, Sergio Elias; Acosta, Leopoldo; Toledo, Jonay

    2009-01-01

    A simple, economic and successful design for distance and cable length detection is presented. The measurement system is based on the continuous repetition of a pulse that endlessly travels along the distance to be detected. There is a pulse repeater at both ends of the distance or cable to be measured. The endless repetition of the pulse generates a frequency that varies almost inversely with the distance to be measured. The resolution and distance or cable length range could be adjusted by varying the repetition time delay introduced at both ends and the measurement time. With this design a distance can be measured with centimeter resolution using electronic system with microsecond resolution, simplifying classical time of flight designs which require electronics with picosecond resolution. This design was also applied to position measurement. PMID:22303169

  17. Automated statistical modeling of analytical measurement systems

    International Nuclear Information System (INIS)

    Jacobson, J.J.

    1992-01-01

    The statistical modeling of analytical measurement systems at the Idaho Chemical Processing Plant (ICPP) has been completely automated through computer software. The statistical modeling of analytical measurement systems is one part of a complete quality control program used by the Remote Analytical Laboratory (RAL) at the ICPP. The quality control program is an integration of automated data input, measurement system calibration, database management, and statistical process control. The quality control program and statistical modeling program meet the guidelines set forth by the American Society for Testing Materials and American National Standards Institute. A statistical model is a set of mathematical equations describing any systematic bias inherent in a measurement system and the precision of a measurement system. A statistical model is developed from data generated from the analysis of control standards. Control standards are samples which are made up at precise known levels by an independent laboratory and submitted to the RAL. The RAL analysts who process control standards do not know the values of those control standards. The object behind statistical modeling is to describe real process samples in terms of their bias and precision and, to verify that a measurement system is operating satisfactorily. The processing of control standards gives us this ability

  18. A performance measurement system for engineering services

    Science.gov (United States)

    West, R. L.

    1985-01-01

    A performance measurement system which provides both a means of monitoring performance and a resource to support management decision making is described. The process of performance indicator development is discussed and typical indicators are described. The paper concludes with a summary of some of the lessons learned in applying productivity measurements to engineering services tasks and in automating data collection, evaluation and interpretation.

  19. System Controls and Measures Oxygen Fugacity

    Science.gov (United States)

    Williams, R. J.

    1982-01-01

    System developed at Johnson Space Center controls and measures oxygen fugacity in high-temperature chemical research. A ceramic-electrolyte cell is the sensing element. All hardware needed to control gas flow and temperature and to measure cell electromotive force is included. An analytic balance allows in situ thermogravimetric sample analysis.

  20. Measurement trends for future safeguards systems

    International Nuclear Information System (INIS)

    Baloga, S.M.; Hakkila, E.A.

    1980-01-01

    Safeguards for future commercial-scale nuclear facilities may employ three materials control and accounting concepts: classical accounting, dynamic materials balancing, and independent verification of inventories and materials balances. Typical measurement needs associated with the implementation of these concepts at high-throughput facilities are discussed. Promising measurement methods for meeting these needs are described and recent experience is cited. General directions and considerations for meeting advanced safeguards systems needs through measurement technology development over the next decade are presented

  1. Dynamic Properties of Impulse Measuring Systems

    DEFF Research Database (Denmark)

    Pedersen, A.; Lausen, P.

    1971-01-01

    After some basic considerations the dynamic properties of the measuring system are subjected to a general examination based on a number of responses, characteristic of the system. It is demonstrated that an impulse circuit has an internal impedance different from zero, for which reason...

  2. CITYkeys Smart city performance measurement system

    NARCIS (Netherlands)

    Huovila, A.; Airaksinen, M.; Pinto-Seppa, I.; Piira, K.; Bosch, P.R.; Penttinen, T.; Neumann, H.M.; Kontinakis, N.

    2017-01-01

    Cities are tackling their economic, social and environmental challenges through smart city solutions. To demonstrate that these solutions achieve the desired impact, an indicator-based assessment system is needed. This paper presents the process of developing CITYkeys performance measurement system

  3. Internal Performance Measurement Systems: Problems and Solutions

    DEFF Research Database (Denmark)

    Jakobsen, Morten; Mitchell, Falconer; Nørreklit, Hanne

    2010-01-01

    . The analysis uses and extends N rreklit's (2000) critique of the BSC by applying the concepts developed therein to contemporary research on the BSC and to the development of practice in performance measurement. The analysis is of relevance for many companies in the Asia-Pacific area as an increasing numbers......This article pursues two aims: to identify problems and dangers related to the operational use of internal performance measurement systems of the Balanced Scorecard (BSC) type and to provide some guidance on how performance measurement systems may be designed to overcome these problems...

  4. Measuring Vulnerability in the Food System

    OpenAIRE

    Paloviita, Ari; Puupponen, Antti; Kortetmäki, Teea; Silvasti, Tiina

    2015-01-01

    Food system vulnerability is an emerging concept for food security policies and food supply chain management. Hence, measuring food system vulnerability is necessary for developing appropriate food security policies and managing food supply chain vulnerabilities. In this paper, we aim to clarify the development process of food system vulnerability indicators. We conducted an abducted qualitative content analysis based on public documents of various Finnish organizations, including mi...

  5. NKS MOMS. Final report. [Mobile Measurement Systems

    Energy Technology Data Exchange (ETDEWEB)

    Nilssen, J. [Norwegian Radiation Protection Authority (NRPA) (Norway); Aage, H.K. [Danish Emergency Management Agency (DEMA) (Denmark); Palsson, S.E. [Icelandic Radiation Safety Authority (IRSA) (Iceland)

    2013-02-15

    Mobile car-borne measurement systems are an important asset in early phase emergency response in all Nordic countries. However, through the development of the systems in the different countries, there are considerable differences between the systems developed. This complicates Nordic cooperation and mutual assistance in emergency situations. This project aimed to facilitate harmonization of mobile measurement systems between the Nordic countries. The project focused on harmonizing data formats, information exchange and measurement strategies. Although the work done was funded by each member, the project established a good platform for cooperation which will hopefully continue beyond the scope of the project. A two-day seminar was held in May 2012, where all participants presented the current status (equipment, methods used etc.), in addition to invited speakers presenting development within the field of mobile detection and in situ measurements. Exchange of experiences and information on different measurement systems and practises in use was an important part of the seminar. The seminar was followed up by a small workshop during the REFOX exercise in Lund, Sweden, September 2012. Exchange of measurement data from the exercise was facilitated through a workspace proveded by NRPA as part of the MOMS project. The work done in this project will be presented at the NordEx12 seminar in March 2013. (Author)

  6. Multichannel simultaneous magnetic induction measurement system (MUSIMITOS)

    International Nuclear Information System (INIS)

    Steffen, Matthias; Leonhardt, Steffen; Heimann, Konrad; Bernstein, Nina

    2008-01-01

    Non-contact heart and lung activity monitoring would be a desirable supplement to conventional monitoring techniques. Based on the potential of non-contact magnetic induction measurements, requirements for an adequate monitoring system were estimated. This formed the basis for the development of the presented extendable multichannel simultaneous magnetic induction measurement system (MUSIMITOS). Special focus was given to the dynamic behaviour and simultaneous multichannel measurements, so that the system allows for up to 14 receiver coils working simultaneously at 6 excitation frequencies. Moreover, a real-time software concept for online signal processing visualization in combination with a fast software demodulation is presented. Finally, first steps towards a clinical application are pointed out and technical performance as well as first in vivo measurements are presented. This paper covers some aspects previously presented in Steffen and Leonhardt (2007 Proc. 13th Int. Conf. on Electrical Bioimpedance and the 8th Conf. on Electrical Impedance Tomography, Graz 2007)

  7. Image processing system for flow pattern measurements

    International Nuclear Information System (INIS)

    Ushijima, Satoru; Miyanaga, Yoichi; Takeda, Hirofumi

    1989-01-01

    This paper describes the development and application of an image processing system for measurements of flow patterns occuring in natural circulation water flows. In this method, the motions of particles scattered in the flow are visualized by a laser light slit and they are recorded on normal video tapes. These image data are converted to digital data with an image processor and then transfered to a large computer. The center points and pathlines of the particle images are numerically analized, and velocity vectors are obtained with these results. In this image processing system, velocity vectors in a vertical plane are measured simultaneously, so that the two dimensional behaviors of various eddies, with low velocity and complicated flow patterns usually observed in natural circulation flows, can be determined almost quantitatively. The measured flow patterns, which were obtained from natural circulation flow experiments, agreed with photographs of the particle movements, and the validity of this measuring system was confirmed in this study. (author)

  8. Linear systems a measurement based approach

    CERN Document Server

    Bhattacharyya, S P; Mohsenizadeh, D N

    2014-01-01

    This brief presents recent results obtained on the analysis, synthesis and design of systems described by linear equations. It is well known that linear equations arise in most branches of science and engineering as well as social, biological and economic systems. The novelty of this approach is that no models of the system are assumed to be available, nor are they required. Instead, a few measurements made on the system can be processed strategically to directly extract design values that meet specifications without constructing a model of the system, implicitly or explicitly. These new concepts are illustrated by applying them to linear DC and AC circuits, mechanical, civil and hydraulic systems, signal flow block diagrams and control systems. These applications are preliminary and suggest many open problems. The results presented in this brief are the latest effort in this direction and the authors hope these will lead to attractive alternatives to model-based design of engineering and other systems.

  9. A Critique of Health System Performance Measurement.

    Science.gov (United States)

    Lynch, Thomas

    2015-01-01

    Health system performance measurement is a ubiquitous phenomenon. Many authors have identified multiple methodological and substantive problems with performance measurement practices. Despite the validity of these criticisms and their cross-national character, the practice of health system performance measurement persists. Theodore Marmor suggests that performance measurement invokes an "incantatory response" wrapped within "linguistic muddle." In this article, I expand upon Marmor's insights using Pierre Bourdieu's theoretical framework to suggest that, far from an aberration, the "linguistic muddle" identified by Marmor is an indicator of a broad struggle about the representation and classification of public health services as a public good. I present a case study of performance measurement from Alberta, Canada, examining how this representational struggle occurs and what the stakes are. © The Author(s) 2015.

  10. Nondestructive surface profiling of hidden MEMS using an infrared low-coherence interferometric microscope

    Science.gov (United States)

    Krauter, Johann; Osten, Wolfgang

    2018-03-01

    There are a wide range of applications for micro-electro-mechanical systems (MEMS). The automotive and consumer market is the strongest driver for the growing MEMS industry. A 100 % test of MEMS is particularly necessary since these are often used for safety-related purposes such as the ESP (Electronic Stability Program) system. The production of MEMS is a fully automated process that generates 90 % of the costs during the packaging and dicing steps. Nowadays, an electrical test is carried out on each individual MEMS component before these steps. However, after encapsulation, MEMS are opaque to visible light and other defects cannot be detected. Therefore, we apply an infrared low-coherence interferometer for the topography measurement of those hidden structures. A lock-in algorithm-based method is shown to calculate the object height and to reduce ghost steps due to the 2π -unambiguity. Finally, measurements of different MEMS-based sensors are presented.

  11. Coordinate metrology accuracy of systems and measurements

    CERN Document Server

    Sładek, Jerzy A

    2016-01-01

    This book focuses on effective methods for assessing the accuracy of both coordinate measuring systems and coordinate measurements. It mainly reports on original research work conducted by Sladek’s team at Cracow University of Technology’s Laboratory of Coordinate Metrology. The book describes the implementation of different methods, including artificial neural networks, the Matrix Method, the Monte Carlo method and the virtual CMM (Coordinate Measuring Machine), and demonstrates how these methods can be effectively used in practice to gauge the accuracy of coordinate measurements. Moreover, the book includes an introduction to the theory of measurement uncertainty and to key techniques for assessing measurement accuracy. All methods and tools are presented in detail, using suitable mathematical formulations and illustrated with numerous examples. The book fills an important gap in the literature, providing readers with an advanced text on a topic that has been rapidly developing in recent years. The book...

  12. Novel surface measurement system reading cost savings

    Energy Technology Data Exchange (ETDEWEB)

    Sword, M.

    1996-05-01

    A new state-of-the-art data acquisition system for the oil and natural gas industries is being marketed by OPSCO`92 Industries Ltd. The unit is portable, it measures surface data which is calibrated to bottom-hole conditions and designed to measure temperature and pressure information without the necessity of sending testing equipment downhole. The Surface Data System (SDS) uses silicon-crystal technology, is mounted in a suitcase size carrying case, and runs off a 12-volt battery enclosure which can be backed up by a small solar panel. The first generation system can handle 16 different channels of information input on a laptop computer. Pressure, pressure differential, temperature, frequency and pulse signals for flow meter measurements are handled by standard sensors. Areas of application include build-up and fall-off tests, pipeline evaluation, pre-frac tests, underbalanced drilling and gas well evaluation. 1 fig., 1 photo.

  13. Video integrated measurement system. [Diagnostic display devices

    Energy Technology Data Exchange (ETDEWEB)

    Spector, B.; Eilbert, L.; Finando, S.; Fukuda, F.

    1982-06-01

    A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides an innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.

  14. Tritium monitoring system for near ambient measurements

    International Nuclear Information System (INIS)

    Falter, K.G.; Bauer, M.L.

    1992-01-01

    This paper describes the current status of research on an improved tritium measurement system at the Oak Ridge National Laboratory (ORNL) for the U.S. Navy. Present tritium-in-air monitoring systems installed by the Navy can reliably measure to less than 10 μCi/m 3 , but medical and safety issues are pushing measurement needs to below 1 μCi/m 3 , which is equivalent to 1-10 nCi/ml in liquid samples, using calcium metal converter. A significant effort has been expended over the past 10 years by the Navy RADIAC Development Program at ORNL on various schemes to improve the detection of tritium in both air and liquid at near ambient levels. One such scheme includes a liquid flow-through system based on an NE102 sponge scintillator with dual photomultiplier tubes for tube noise rejection

  15. Eddy Correlation Flux Measurement System Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Cook, D. R. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-01-01

    The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO2) (and methane at one Southern Great Plains extended facility (SGP EF) and the North Slope of Alaska Central Facility (NSA CF). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO2 concentration. The instruments used are: • a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature) • an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO2 concentration, and • an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at one SGP EF and at the NSA CF. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A Surface Energy Balance System (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), ARM Mobile Facility 1 (AMF1), and ARM Mobile Facility 2 (AMF2). The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. The SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes. The SEBS at one SGP and one NSA site also support upwelling and downwelling PAR measurements to qualify those two locations as Ameriflux sites.

  16. Design of an Antenna Measurement System

    Science.gov (United States)

    Patel, Kyle

    Modern communication systems require next generation antenna, whose performance can only be verified through specialized equipment and methodology. For example, a vector network analyzer can be used to determine metrics such as the impedance bandwidth of an antenna. However, a vector network analyzer provides only a portion of the operational characteristics of an antenna. Instead, controlled environments known as anechoic chambers are used to ascertain the radiation characteristics of an antenna under test. These facilities typically incorporate a variety of different instruments to facilitate the measurement process. Rotary tables, linear actuators, vector network analyzers, and amplifiers are examples of typical components that are used in an anechoic chamber. While one could certainly manually control these components, it is more efficient to automate the measurement procedure. This saves time and increases repeatability of measurements. This thesis presents a complete software design for automated antenna measurement system for use in anechoic chambers. This developed software is both modular and flexible, which allows for easy adaptation for new equipment over time and allows the system to run in a simulation mode if some hardware components are not present. The system has also proven its capability by successfully measuring the radiation pattern of a dipole antenna, even in an anechoic chamber lacking wall-to-wall absorbers.

  17. Electronic system for Langmuir probe measurements

    Science.gov (United States)

    Mitov, M.; Bankova, A.; Dimitrova, M.; Ivanova, P.; Tutulkov, K.; Djermanova, N.; Dejarnac, R.; Stöckel, J.; Popov, Tsv K.

    2012-03-01

    A newly developed Langmuir probe system for measurements of current-voltage (IV) characteristics in the tokamak divertor area is presented and discussed. The system is partially controlled by a computer allowing simultaneous and independent feeding and registration of signals. The system is mounted in the COMPASS tokamak, Institute of Plasma Physics, Academy of Sciences of the Czech Republic. The new electronic circuit boards include also active low-pass filters which smooth the signal before recording by the data acquisition system (DAQ). The signal is thus less noisy and the data processing is much easier. We also designed and built a microcontroller-driven waveform generator with resolution of 1 Ms/s. The power supply is linear and uses a transformer. We avoided the use of a switching power supply because of the noise that it could generate. Examples of measurements of the IV characteristics by divertor probes in the COMPASS tokamak and evaluation of the EEDF are presented.

  18. Displacement measurement system for linear array detector

    International Nuclear Information System (INIS)

    Zhang Pengchong; Chen Ziyu; Shen Ji

    2011-01-01

    It presents a set of linear displacement measurement system based on encoder. The system includes displacement encoders, optical lens and read out circuit. Displacement read out unit includes linear CCD and its drive circuit, two amplifier circuits, second order Butterworth low-pass filter and the binarization circuit. The coding way is introduced, and various parts of the experimental signal waveforms are given, and finally a linear experimental test results are given. The experimental results are satisfactory. (authors)

  19. Measurement system for SSRF pulsed magnets

    International Nuclear Information System (INIS)

    Peng Chengcheng; Gu Ming; Liu Bo; Ouyang Lianhua

    2007-01-01

    This paper describes the magnetic field measurement system for pulsed magnets in SSRF. The system consists of magnetic probes, analog active integrator, oscilloscope, stepper motor and a controller. An application program based on LabVIEW has been developed as main control unit. After the magnetic field mapping of a septum magnet prototype, it is verified that the test results accord with the results of theoretical calculation and computer simulation. (authors)

  20. Reactivity Measurement and Analysis System (RMAS-7)

    Energy Technology Data Exchange (ETDEWEB)

    Cordero, D.; Izquierdo, J.

    2015-07-01

    This paper tries to describe the Reactivity Measurement and Analysis System 7 (RMAS-7), which is an Areva’s hardware and software solution capable of accomplishing the physic startup tests in a work shift. RMAS-7 is a modular solution designed to be a powerful, convenient data collection and analysis system based on Ethernet communication network. This last feature allows RMAS-7 to have a distributed architecture. (Author)

  1. Quantum system lifetimes and measurement perturbations

    International Nuclear Information System (INIS)

    Najakov, E.

    1977-05-01

    The recently proposed description of quantum system decay in terms of repeated measurement perturbations is modified. The possibility of retarded reductions to a unique quantum state, due to ineffective localization of the decay products at initial time measurements, is simply taken into account. The exponential decay law is verified again. A modified equation giving the observed lifetime in terms of unperturbed quantum decay law, measurement frequency and reduction law is derived. It predicts deviations of the observed lifetime from the umperturbed one, together with a dependence on experimental procedures. The influence of different model unperturbed decay laws and reduction laws on this effect is studied

  2. Linear heating system for measurement of thermoluminescence ...

    Indian Academy of Sciences (India)

    Unknown

    scence intensity is monitored. The theory of TL usually assumes that the sample temperature varies linearly with time, although more general theories have been formu- lated and calculations made for non-linear heating system. Previous descriptions of apparatus for the measurement of TL have been published elsewhere ...

  3. Characteristics of a simple blackbody measurement system

    International Nuclear Information System (INIS)

    Fu, C.; Anger, N.H.; Kaehms, R.; Jaeger, K.B.

    1988-01-01

    An axially symmetric blackbody (BB) measurement system with a circular aperture and a circular detector is considered. The BB can be of a right circular conical shape, a right cylindrical shape, or a combination of these two shapes. Assuming that the BB is ideal, the power received by the detector is calculated. 8 references

  4. Power system observability with minimum phasor measurement ...

    African Journals Online (AJOL)

    user

    This paper presents optimal phasor measurement units (PMUs) placement algorithms for power system observability. The optimal placement problem (OPP) is formulated such that minimizing the number of PMU installations for full network observability. Three approaches, in this paper, are introduced aiming at reducing ...

  5. SIMS: The SLAC Industrial Measurement System

    International Nuclear Information System (INIS)

    Bell, B.

    1990-01-01

    Kern was the first survey company to market an Industrial Measurement System when it released ECDS (Electronic Coordinate Determination System) in the mid-1980s. Originally written for the PDP-11, a version was later released for the PC (ECDS-PC). SLAC purchased this system in 1986 and immediately began to use it for the alignment of the SLC (Stanford Linear Collider). Although ECDS enabled SLAC to perform tasks with a speed never before achieved, they experienced limitations in the software. Since Kern proved unresponsive and SLAC was unable to purchase the source code for any amount of money, they set about writing their own portions of code. They first wrote a system of menus tailored for their specific alignment tasks, and disabled much of the ECDS menu structure. Due to dissatisfaction with the ECDS bundle adjustment program, they wrote their own bundle adjustment in 1988. A further step towarad having their own complete IMS was to develop a data capture program, a task which has been underway since the beginning of this year. They do not yet have data analysis features that are fully integrated, but they do have stand-alone packages that have been written at SLAC. When they first started tinkering with ECDS there was no intention of developing a complete system, but they now have all the elements of such a system - SIMS, the SLAC Industrial Measurement System

  6. Blade Vibration Measurement System for Unducted Fans

    Science.gov (United States)

    Marscher, William

    2014-01-01

    With propulsion research programs focused on new levels of efficiency and noise reduction, two avenues for advanced gas turbine technology are emerging: the geared turbofan and ultrahigh bypass ratio fan engines. Both of these candidates are being pursued as collaborative research projects between NASA and the engine manufacturers. The high bypass concept from GE Aviation is an unducted fan that features a bypass ratio of over 30 along with the accompanying benefits in fuel efficiency. This project improved the test and measurement capabilities of the unducted fan blade dynamic response. In the course of this project, Mechanical Solutions, Inc. (MSI) collaborated with GE Aviation to (1) define the requirements for fan blade measurements; (2) leverage MSI's radar-based system for compressor and turbine blade monitoring; and (3) develop, validate, and deliver a noncontacting blade vibration measurement system for unducted fans.

  7. Sustainable Food Security Measurement: A Systemic Methodology

    Science.gov (United States)

    Findiastuti, W.; Singgih, M. L.; Anityasari, M.

    2017-04-01

    Sustainable food security measures how a region provides food for its people without endangered the environment. In Indonesia, it was legally measured in Food Security and Vulnerability (FSVA). However, regard to sustainable food security policy, the measurement has not encompassed the environmental aspect. This will lead to lack of environmental aspect information for adjusting the next strategy. This study aimed to assess Sustainable Food security by encompassing both food security and environment aspect using systemic eco-efficiency. Given existing indicator of cereal production level, total emission as environment indicator was generated by constructing Causal Loop Diagram (CLD). Then, a stock-flow diagram was used to develop systemic simulation model. This model was demonstrated for Indonesian five provinces. The result showed there was difference between food security order with and without environmental aspect assessment.

  8. Improvement of Ultrasonic Distance Measuring System

    Directory of Open Access Journals (Sweden)

    Jiang Yu

    2018-01-01

    Full Text Available This paper mainly introduces a kind of ultrasonic distance measuring system with AT89C51 single chip as the core component. The paper expounds the principle of ultrasonic sensor and ultrasonic ranging, hardware circuit and software program, and the results of experiment and analysis.The hardware circuit based on SCM, the software design adopts the advanced microcontroller programming language.The amplitude of the received signal and the time of ultrasonic propagation are regulated by closed loop control. [1,2]The double closed loop control technology for amplitude and time improves the measuring accuracy of the instrument. The experimental results show that greatly improves the measurement accuracy of the system.

  9. Multi-scale biomedical systems: measurement challenges

    International Nuclear Information System (INIS)

    Summers, R

    2016-01-01

    Multi-scale biomedical systems are those that represent interactions in materials, sensors, and systems from a holistic perspective. It is possible to view such multi-scale activity using measurement of spatial scale or time scale, though in this paper only the former is considered. The biomedical application paradigm comprises interactions that range from quantum biological phenomena at scales of 10-12 for one individual to epidemiological studies of disease spread in populations that in a pandemic lead to measurement at a scale of 10+7. It is clear that there are measurement challenges at either end of this spatial scale, but those challenges that relate to the use of new technologies that deal with big data and health service delivery at the point of care are also considered. The measurement challenges lead to the use, in many cases, of model-based measurement and the adoption of virtual engineering. It is these measurement challenges that will be uncovered in this paper. (paper)

  10. System for measuring radioactivity of labelled biopolymers

    International Nuclear Information System (INIS)

    Gross, V.

    1980-01-01

    A system is described for measuring radioactivity of labelled biopolymers, comprising: a set of containers adapted for receiving aqueous solutions of biological samples containing biopolymers which are subsequently precipitated in said containers on particles of diatomite in the presence of a coprecipitator, then filtered, dissolved, and mixed with a scintillator; radioactivity measuring means including a detection chamber to which is fed the mixture produced in said set of containers; an electric drive for moving said set of containers in a stepwise manner; means for proportional feeding of said coprecipitator and a suspension of diatomite in an acid solution to said containers which contain the biological sample for forming an acid precipitation of biopolymers; means for the removal of precipitated samples from said containers; precipitated biopolymer filtering means for successively filtering the precipitate, suspending the precipitate, dissolving the biopolymers mixed with said scintillator for feeding of the mixture to said detection chamber; a system of pipelines interconnecting said above-recited means; and said means for measuring radioactivity of labelled biopolymers including, a measuring cell arranged in a detection chamber and communicating with said means for filtering precipitated biopolymers through one pipeline of said system of pipelines; a program unit electrically connected to said electric drive, said means for acid precipatation of biopolymers, said means for the removal of precipitated samples from said containers, said filtering means, and said radioactivity measuring device; said program unit adapted to periodically switch on and off the above-recited means and check the sequence of the radioactivity measuring operations; and a control unit for controlling the initiation of the system and for selecting programs

  11. Fully automated system for pulsed NMR measurements

    International Nuclear Information System (INIS)

    Cantor, D.M.

    1977-01-01

    A system is described which places many of the complex, tedious operations for pulsed NMR experiments under computer control. It automatically optimizes the experiment parameters of pulse length and phase, and precision, accuracy, and measurement speed are improved. The hardware interface between the computer and the NMR instrument is described. Design features, justification of the choices made between alternative design strategies, and details of the implementation of design goals are presented. Software features common to all the available experiments are discussed. Optimization of pulse lengths and phases is performed via a sequential search technique called Uniplex. Measurements of the spin-lattice and spin-spin relaxation times and of diffusion constants are automatic. Options for expansion of the system are explored along with some of the limitations of the system

  12. Torsional ultrasonic wave based level measurement system

    Science.gov (United States)

    Holcomb, David E [Oak Ridge, TN; Kisner, Roger A [Knoxville, TN

    2012-07-10

    A level measurement system suitable for use in a high temperature and pressure environment to measure the level of coolant fluid within the environment, the system including a volume of coolant fluid located in a coolant region of the high temperature and pressure environment and having a level therein; an ultrasonic waveguide blade that is positioned within the desired coolant region of the high temperature and pressure environment; a magnetostrictive electrical assembly located within the high temperature and pressure environment and configured to operate in the environment and cooperate with the waveguide blade to launch and receive ultrasonic waves; and an external signal processing system located outside of the high temperature and pressure environment and configured for communicating with the electrical assembly located within the high temperature and pressure environment.

  13. Measuring the Balance Control System – Review

    Directory of Open Access Journals (Sweden)

    Jitka Jančová

    2008-01-01

    Full Text Available Past studies of postural control during standing have employed wide range of procedures including the outcome measures use to quantify postural control, the duration of the sample collected, sampling frequency and methods for data processing. Due to these differences there remains little, if any, common grounds for comparisons between studies to establish a concrete understanding of the features and bouns which characterize normal healthy postural control. This article deals with terms such as reliability and repeatability of stabilometric measurements, stabilometric data quantification and analysis. To clear up those terms is suggested, by the author of this paper, very important. The stabilometric measurements remain, nevertheless, different when dealing with aging adults. Though, we notes some alterations of the aging systems, this article is not entirely dedicated to the seniors population. Measurements of COP and technical notes remain the main axis of present paper.

  14. Eddy Correlation Flux Measurement System (ECOR) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Cook, DR

    2011-01-31

    The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO2) (and methane at one Southern Great Plains extended facility (SGP EF) and the North Slope of Alaska Central Facility (NSA CF). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO2 concentration.

  15. Slot Antenna for Wireless Temperature Measurement Systems

    DEFF Research Database (Denmark)

    Acar, Öncel; Jakobsen, Kaj Bjarne

    2016-01-01

    This paper presents a novel clover-slot antenna for a surface-acoustic-wave sensor based wireless temperature measurement system. The slot is described by a parametric locus curve that has the shape of a clover. The antenna is operated at high temperatures, in rough environments, and has a 43......% fractional bandwidth at the 2.4 GHz ISM-band. The slot antenna has been optimized for excitation by a passive chip soldered onto it. Measurement results are compared with simulation results and show good agreements....

  16. Flavor release measurement from gum model system

    DEFF Research Database (Denmark)

    Ovejero-López, I.; Haahr, Anne-Mette; van den Berg, Frans W.J.

    2004-01-01

    Flavor release from a mint-flavored chewing gum model system was measured by atmospheric pressure chemical ionization mass spectroscopy (APCI-MS) and sensory time-intensity (TI). A data analysis method for handling the individual curves from both methods is presented. The APCI-MS data are ratio...... composition can be measured by both instrumental and sensory techniques, providing comparable information. The peppermint oil level (0.5-2% w/w) in the gum influenced both the retronasal concentration and the perceived peppermint flavor. The sweeteners' (sorbitol or xylitol) effect is less apparent. Sensory...

  17. MEMS based Doppler velocity measurement system

    Science.gov (United States)

    Shin, Minchul

    The design, fabrication, modeling and characterization of a capacitive micromachined ultrasonic transducer (cMUT) based in-air Doppler velocity measurement system using a 1 cm2 planar array are described. Continuous wave operation in a narrowband was chosen in order to maximize range, as it allows for better rejection of broadband noise. The sensor array has a 160-185 kHz resonant frequency to achieve a 10 degree beamwidth. A model for the cMUT and the acoustic system which includes electrical, mechanical, and acoustic components is provided. Furthermore, characterization of the cMUT sensor with a variety of testing procedures is provided. Laser Doppler vibrometry (LDV), beampattern, reflection, and velocity testing characterize the performance of the sensors. The sensor is capable of measuring the velocity of a moving specular reflector with a resolution of 5 cm/s, an update rate of 0.016 second, and a range of 1.5 m.

  18. Vacuum measuring system for channel electron multipliers

    Science.gov (United States)

    Urban, A.; Ritzinger, W.

    1982-03-01

    A system in which channel electron multipliers can be calibrated to be used as detectors of electrons or protons in space is described. The system consists of an electron gun built in a vacuum chamber and equipped with a control Faraday cup and a high impedance electrometer to measure electron fluxes. It contains an electron flux control with buffer amplifier, a proportional integration differentiation regulation unit, and a heating current power regulation. Detection efficiency dependency on the energy of the incident particles, the saturation that yields decreasing count rates at continuously increasing particle flux, or the statistical pulse height distribution giving information about well or restrictedly usuable multipliers can be measured. The optimum supply voltage of the multipliers at which small fluctuations do not cause any changes of the pulse height distribution, and the function count rates vs. supply voltage for selecting good or poor multipliers can also be determined.

  19. Measuring cell identity in noisy biological systems

    Science.gov (United States)

    Birnbaum, Kenneth D.; Kussell, Edo

    2011-01-01

    Global gene expression measurements are increasingly obtained as a function of cell type, spatial position within a tissue and other biologically meaningful coordinates. Such data should enable quantitative analysis of the cell-type specificity of gene expression, but such analyses can often be confounded by the presence of noise. We introduce a specificity measure Spec that quantifies the information in a gene's complete expression profile regarding any given cell type, and an uncertainty measure dSpec, which measures the effect of noise on specificity. Using global gene expression data from the mouse brain, plant root and human white blood cells, we show that Spec identifies genes with variable expression levels that are nonetheless highly specific of particular cell types. When samples from different individuals are used, dSpec measures genes’ transcriptional plasticity in each cell type. Our approach is broadly applicable to mapped gene expression measurements in stem cell biology, developmental biology, cancer biology and biomarker identification. As an example of such applications, we show that Spec identifies a new class of biomarkers, which exhibit variable expression without compromising specificity. The approach provides a unifying theoretical framework for quantifying specificity in the presence of noise, which is widely applicable across diverse biological systems. PMID:21803789

  20. Space Acceleration Measurement System-II

    Science.gov (United States)

    Foster, William

    2009-01-01

    Space Acceleration Measurement System (SAMS-II) is an ongoing study of the small forces (vibrations and accelerations) on the ISS that result from the operation of hardware, crew activities, as well as dockings and maneuvering. Results will be used to generalize the types of vibrations affecting vibration-sensitive experiments. Investigators seek to better understand the vibration environment on the space station to enable future research.

  1. Designing an accurate system for temperature measurements

    Directory of Open Access Journals (Sweden)

    Kochan Orest

    2017-01-01

    Full Text Available The method of compensation of changes in temperature field along the legs of inhomogeneous thermocouple, which measures a temperature of an object, is considered in this paper. This compensation is achieved by stabilization of the temperature field along the thermocouple. Such stabilization does not allow the error due to acquired thermoelectric inhomogeneity to manifest itself. There is also proposed the design of the furnace to stabilize temperature field along the legs of the thermocouple which measures the temperature of an object. This furnace is not integrated with the thermocouple mentioned above, therefore it is possible to replace this thermocouple with a new one when it get its legs considerably inhomogeneous.. There is designed the two loop measuring system with the ability of error correction which can use simultaneously a usual thermocouple as well as a thermocouple with controlled profile of temperature field. The latter can be used as a reference sensor for the former.

  2. Nuclear instrumentation for the industrial measuring systems

    International Nuclear Information System (INIS)

    Normand, S.

    2010-01-01

    This work deals with nuclear instrumentation and its application to industry, power plant fuel reprocessing plant and finally with homeland security. The first part concerns the reactor instrumentation, in-core and ex-core measurement system. Ionization Uranium fission chamber will be introduced with their acquisition system especially Campbell mode system. Some progress have been done on regarding sensors failure foresee. The second part of this work deals with reprocessing plant and associated instrumentation for nuclear waste management. Proportional counters techniques will be discussed, especially Helium-3 counter, and new development on electronic concept for reprocessing nuclear waste plant (one electronic for multipurpose acquisition system). For nuclear safety and security for human and homeland will be introduce. First we will explain a new particular approach on operational dosimetric measurement and secondly, we will show new kind of organic scintillator material and associated electronics. Signal treatment with real time treatment is embedded, in order to make neutron gamma discrimination possible even in solid organic scintillator. Finally, the conclusion will point out future, with most trends in research and development on nuclear instrumentation for next years. (author) [fr

  3. Improvement an enterprises marketing performance measurement system

    Directory of Open Access Journals (Sweden)

    Stanković Ljiljana

    2013-01-01

    Full Text Available Business conditions in which modern enterprises do business are more and more complex. The complexity of the business environment is caused by activities of external and internal factors, which imposes the need for the turn in management focus. One of key turns is related to the need of adaptation and development of new business performance evaluation systems. The evaluation of marketing contribution to business performance is very important however a complex task as well. The marketing theory and practice indicates the need for developing adequate standards and systems for evaluating the efficiency of marketing decisions. The better understanding of marketing standards and ways that managers use is a very important factor that affects the efficiency of strategic decision-making. The paper presents the results of researching the way in which managers perceive and apply marketing performance measures. The data that were received through the field research sample enabled the consideration of the managers' attitudes on practical ways of implementing marketing performance measurement and identifying measures that managers imply as used mostly in business practice.

  4. Multiphase magnetic systems: Measurement and simulation

    Science.gov (United States)

    Cao, Yue; Ahmadzadeh, Mostafa; Xu, Ke; Dodrill, Brad; McCloy, John S.

    2018-01-01

    Multiphase magnetic systems are common in nature and are increasingly being recognized in technical applications. One characterization method which has shown great promise for determining separate and collective effects of multiphase magnetic systems is first order reversal curves (FORCs). Several examples are given of FORC patterns which provide distinguishing evidence of multiple phases. In parallel, a visualization method for understanding multiphase magnetic interaction is given, which allocates Preisach magnetic elements as an input "Preisach hysteron distribution pattern" to enable simulation of different "wasp-waisted" magnetic behaviors. These simulated systems allow reproduction of different major hysteresis loops and FORC patterns of real systems and parameterized theoretical systems. The experimental FORC measurements and FORC diagrams of four commercially obtained magnetic materials, particularly those sold as nanopowders, show that these materials are often not phase pure. They exhibit complex hysteresis behaviors that are not predictable based on relative phase fraction obtained by characterization methods such as diffraction. These multiphase materials, consisting of various fractions of BaFe12O19, ɛ-Fe2O3, and γ-Fe2O3, are discussed.

  5. Automatic radiation measuring system connected with GPS

    International Nuclear Information System (INIS)

    Tanigaki, Minoru

    2014-01-01

    The most serious nuclear disaster in Japan has broken out at Fukushima Daiichi Nuclear Power Plant due to Great East Japan Earthquake. Prompt and exact mapping of the contamination is of great importance for radiation protection and for the environment restoration. We have developed radiation survey systems KURAMA and KURAMA-2 for rapid and exact measurement of radiation dose distribution. The system is composed of a mobile radiation monitor and the computer in office which is for the storage and visualization of the data. They are connected with internet and are operated for continuous radiation measurement while the monitor is moving. The mobile part consists of a survey meter, an interface to transform the output of the survey meter for the computer, a global positioning system, a computer to process the data for connecting to the network, and a mobile router. Thus they are effective for rapid mapping of the surface contamination. The operation and the performance of the equipment at the site are presented. (J.P.N.)

  6. EAST machine assembly and its measurement system

    International Nuclear Information System (INIS)

    Wu, S.T.

    2005-01-01

    The EAST (HT-7U) superconducting tokamak consists of a superconducting poloidal field magnet system, a toroidal field magnet system, a vacuum vessel and in-vessel components, thermal shields and a cryostat vessel. The main parts of the machine have been delivered to ASIPP (Institute of Plasma Physics, Chinese Academy of Sciences) successionally from 2003. For its complicated constitution and precise requirement, a reasonable assembly procedure and measurement technique should be defined carefully. Before the assembly procedure, a reference frame has been set up with reference fiducial targets on the wall of the test hall by an industrial measurement system. After the torus of TF coils is formed, a new reference frame will be set up from the position of the TF torus. The vacuum vessel with all inner parts will be installed with reference of the new reference frame. The big size and mass of components, special configuration of the superconducting machine with tight installation tolerances of the HT-7U (EAST) machine result in complicated assembly procedure. The procedure had begun with the installation of the support frame and the base of cryostat vessel last year. In this paper, the requirements of the assembly precise for some key components of the machine are described. The reference frame for the assembly and maintenance is explained. The assembly procedure is introduced

  7. Measurements of system sharpness for two digital breast tomosynthesis systems

    Science.gov (United States)

    Marshall, N. W.; Bosmans, H.

    2012-11-01

    The aim of this work was to propose system sharpness parameters for digital breast tomosynthesis (DBT) systems that include the influence of focus size and focus motion for use in quality assurance protocols. X-ray focus size was measured using a multiple pinhole test object, while detector presampling modulation transfer function (MTF) was measured from projection images of a 10 cm × 10 cm, 1 mm thick steel edge, for the Siemens Inspiration and Hologic Selenia Dimensions DBT systems. The height of the edge above the table was then varied from 1 to 78 mm. The MTF expected from theory for the projection images was calculated from the measured detector MTF, focus size MTF and focus motion MTF and was compared against measured curves. Two methods were used to measure the in-plane MTF in the DBT volume: a tungsten wire of diameter 25 µm and an Al edge 0.2 mm thick, both imaged with a 15 mm thick poly(methyl methacrylate) (PMMA) plate. The in-depth point spread function (PSF) was measured using an angled tungsten wire. The full 3D MTF was estimated with a 0.5 mm diameter aluminium bead held in a 45 mm thick PMMA phantom, with the bead 15 and 65 mm above the table. Inspiration DBT projection images are saved at native detector resolution (85 µm), while the Dimensions re-bins projections to 140 µm pixels (2 × 2 binning); both systems used 2 × 2 binning of projection data before reconstruction. The 50% point for the MTF (MTF0.50) measured in the DBT projection images for the tube-travel direction fell as a function of height above the table from 3.60 to 0.90 mm-1 for the Inspiration system and from 2.50 to 1.20 mm-1 for the Dimensions unit. The maximum deviation of measured MTF0.50 from the calculated value was 13%. MTF0.50 measured in-plane (tube-travel direction) fell as a function of height above the table from 1.66 to 0.97 mm-1 for the Inspiration system and from 2.21 to 1.31 mm-1 for the Dimensions system. The full-width half-maximum for the in-depth PSF was 3

  8. Magnetic Field Response Measurement Acquisition System

    Science.gov (United States)

    Woodward, Stanley E. (Inventor); Taylor, Bryant D. (Inventor)

    2007-01-01

    Magnetic field response sensors designed as passive inductor- capacit or circuits produce magnetic field responses whose harmonic frequenci es correspond to states of physical properties for which the sensors measure. Power to the sensing element is acquired using Faraday induc tion. A radio frequency antenna produces the time varying magnetic fi eld used for powering the sensor, as well as receiving the magnetic field response of the sensor. An interrogation architecture for disce rning changes in sensor's response frequency, resistance and amplitud e is integral to the method thus enabling a variety of measurements. Multiple sensors can be interrogated using this method, thus eliminat ing the need to have a data acquisition channel dedicated to each se nsor. The method does not require the sensors to be in proximity to a ny form of acquisition hardware. A vast array of sensors can be used as interchangeable parts in an overall sensing system.

  9. Transmission Quality Measurements in DAB+ Broadcast System

    Directory of Open Access Journals (Sweden)

    Gilski Przemysław

    2017-12-01

    Full Text Available In the age of digital media, delivering broadcast content to customers at an acceptable level of quality is one of the most challenging tasks. The most important factor is the efficient use of available resources, including bandwidth. An appropriate way of managing the digital multiplex is essential for both the economic and technical issues. In this paper we describe transmission quality measurements in the DAB+ broadcast system. We provide a methodology for analysing parameters and factors related with the efficiency and reliability of a digital radio link. We describe a laboratory stand that can be used for transmission quality assessment on a regional and national level.

  10. Interactive measurement system for medical images

    International Nuclear Information System (INIS)

    Akatsuka, T.; Kubo, T.

    1980-01-01

    The information obtained by quantitative reading of medical pictures is very effective for diagnosis. However, high level tasks such as pattern recognition are difficult to be automated completely, hence an interactive system is a viable and economical alternative. The physician traces the contour of the object of interest using a graphics pen attached to a tablet digitizer. From these digitized contours, the computer calculates the area, length, number of objects, etc., and extracts shape features. The system comprises a mini-computer, a graphic tablet and a graphic display. At present it is possible to perform the following tasks interactively: pelvimetry with the help of radiographs, measurement of the dimensions of microorgans, estimation of cardiac parameters from ECG, etc. (Auth.)

  11. Material permeance measurement system and method

    Science.gov (United States)

    Hallman, Jr., Russell Louis; Renner, Michael John [Oak Ridge, TN

    2012-05-08

    A system for measuring the permeance of a material. The permeability of the material may also be derived. The system provides a liquid or high concentration fluid bath on one side of a material test sample, and a gas flow across the opposing side of the material test sample. The mass flow rate of permeated fluid as a fraction of the combined mass flow rate of gas and permeated fluid is used to calculate the permeance of the material. The material test sample may be a sheet, a tube, or a solid shape. Operational test conditions may be varied, including concentration of the fluid, temperature of the fluid, strain profile of the material test sample, and differential pressure across the material test sample.

  12. Dual-goniometer system for channeling measurements

    International Nuclear Information System (INIS)

    Linden, M.; Hellborg, R.

    1986-03-01

    This paper describes a two-goniometer system for obtaining azimuthally averaged measurements in channeling experiments. The system consists of a tri-axial master goniometer and a bi-axial goniometer. Both goniometers are controlled by stepping motors. The alignment goniometer has a target holder, which permits the beam spot to be placed anywhere in a 6 x 6 mm 2 square on the target crystal without loosing the target orientation. The design, construction and operation of the goniometers as well as stepping motor control units and programs for computer control of the goniometers are described. Two control programs cover orientation of the target crystal and a number of other normal experimental conditions. (author)

  13. Measurement and control systems using nuclear radiation

    International Nuclear Information System (INIS)

    Melo, Jose Altino Tupinamba; Madi Filho, Tufic

    2007-01-01

    Non-destructive Assay is applied to machines and components quality tests. These elements would not have a good performance if they were conceived without concern about the mechanical project quality, used materials, manufacture processes and inspection and maintenance methodology. In this work, a measure and control system of non destructive processes was developed, using a radioactive source with a defined energy in function of the material to be analyzed. This system involves: interface of input/output (I/O) (hardware) and graphical interface (software). In the non destructive analysis, it is made the comparison of the signal proceeding from the sensor with a signal preset (set point) or analogical signal of reference (Base Line), which is adjusted in the I/O interface. Analyzed the signal, the system will make the decision: to reject or to accept the analyzed material. The I/O interface is implemented by electronic equipment with a MCS51. The purpose of this interface is to supply conditions to exchange information, using serial RS232, between the sensor and the microcomputer. The graphical interface (software) is written in visual C++ language. (author)

  14. CAMEX-3 DC-8 METEOROLOGICAL MEASUREMENT SYSTEM (MMS) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-3 Meteorological Measurement System (MMS) aboard the NASA DC-8 consists of three major systems: an air-motion sensing system to measure air velocity with...

  15. NAMMA DC-8 METEOROLOGICAL MEASUREMENT SYSTEM (MMS) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The NAMMA DC-8 Meteorological Measurement System (MMS) dataset used the MMS, which consists of three major systems: an air-motion sensing system to measure air...

  16. CAMEX-4 DC-8 METEOROLOGICAL MEASUREMENT SYSTEM (MMS) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The NASA DC-8 Meteorological Measurement System consists of three major systems: an air-motion sensing system to measure air velocity with respect to the aircraft,...

  17. CAMEX-4 DC-8 METEOROLOGICAL MEASUREMENT SYSTEM (MMS) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 DC-8 Meteorological Measurement System (MMS) was collected by the MMS, which consists of three major systems: an air-motion sensing system to measure air...

  18. Hydrostatic levelling systems: Measuring at the system limits

    Science.gov (United States)

    Meier, Edi; Geiger, Alain; Ingensand, Hilmar; Licht, Hans; Limpach, Philippe; Steiger, Andreas; Zwyssig, Roger

    2010-09-01

    Three hydrostatic displacement monitoring system applications in Switzerland are discussed; the first concerns experience gained monitoring the foundation of the Albigna dam, the second relating to the underground stability of the Swiss Light Source synchrotron and the third concerning the deformation of a bridge near the city of Lucerne. Two different principles were applied, the Hydrostatic Levelling System (HLS) using the “half-filled pipe principle” developed by the Paul Scherrer Institute and the Large Area Settlement System (LAS) using the “differential pressure principle”. With both systems ground deformations induced by tidal forces can be seen. However, high accuracy of single sensors is not sufficient. A well-designed configuration of the complete system is equally important. On the other hand there are also limits imposed by installation logistics and by the environmental conditions. An example is the bridge monitoring application, where the acceleration along the bridge due to the passage of heavy trucks limits the feasibility of using hydrostatic levelling measurements.

  19. Approach of Measuring System Analyses for Automotive Part Manufacturing

    OpenAIRE

    S. Homrossukon; S. Sansureerungsigun

    2014-01-01

    This work aims to introduce an efficient and to standardize the measuring system analyses for automotive industrial. The study started by literature reviewing about the management and analyses measurement system. The approach of measuring system management, then, was constructed. Such approach was validated by collecting the current measuring system data using the equipments of interest including vernier caliper and micrometer. Their accuracy and precision of measurements were analyzed. Final...

  20. Performance Measurement Systems in Swedish Health Care Services

    OpenAIRE

    Kollberg, Beata

    2007-01-01

    In the quality management literature, measurements are attributed great importance in improving products and processes. Systems for performance measurement assessing financial and non-financial measurements were developed in the late 1980s and early 1990s. The research on performance measurement systems has mainly been focused on the design of different performance measurement systems. Many authors are occupied with the study of the constructs of measures and developing prescriptive models of...

  1. Study on weld bead surface profile and angular distortion in 6 mm thick butt weld joints of SS304 using fiber laser

    Science.gov (United States)

    Bhargava, P.; Paul, C. P.; Mundra, G.; Premsingh, C. H.; Mishra, S. K.; Nagpure, D.; Kumar, Atul; Kukreja, L. M.

    2014-02-01

    We deployed a 2 kW continuous wave fiber laser integrated with the 5-axis workstation to understand the effect of various processing parameters (laser power, welding speed, beam spot size and chamfer at welded edges) on depth of penetration, angular distortion and welded bead surface profile during autogenous laser welding of 6 mm thick austenitic stainless steel type 304 plates. Full penetration with reduced weld bead surface undulation (joints having chamfered edges of 0.8 mm. The microscopic studies revealed grossly defect-free fusion zone with a few porosities at isolated locations. The microstructure at the fusion zone was largely austenitic with few ferrites and the direction of growth was epitaxial towards the fusion line. The measured values of microhardness at base material and fusion zone were 208±4 HV0.1 and 235±10 HV0.1 respectively. The tensile testing of laser welded samples indicated the ultimate strength >605 MPa and these samples could be bent for an angle >170° without noticeable crack during bend test. The study opened the avenues for the deployment of fiber laser welding technology for applications demanding critical values of surface weld bead profile and distortion.

  2. Calibration and Validation of Measurement System

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Riemann, Sven; Knapp, Wilfried

    The report deals with the calibration of the measuring equipment on board the Wave Dragon, Nissum Bredning prototype.......The report deals with the calibration of the measuring equipment on board the Wave Dragon, Nissum Bredning prototype....

  3. Gas exchange measurements in natural systems

    International Nuclear Information System (INIS)

    Broecker, W.S.; Peng, T.H.

    1983-01-01

    Direct knowledge of the rates of gas exchange in lakes and the ocean is based almost entirely on measurements of the isotopes 14 C, 222 Rn and 3 He. The distribution of natural radiocarbon has yielded the average rate of CO 2 exchange for the ocean and for several closed basin lakes. That of bomb produced radiocarbon has been used in the same systems. The 222 Rn to 226 Ra ratio in open ocean surface water has been used to give local short term gas exchange rates. The radon method generally cannot be used in lakes, rivers, estuaries or shelf areas because of the input of radon from sediments. A few attempts have been made to use the excess 3 He produced by decay of bomb produced tritium in lakes to give gas transfer rates. The uncertainty in the molecular diffusivity of helium and in the diffusivity dependence of the rate of gas transfer holds back the application of this method. A few attempts have been made to enrich the surface waters of small lakes with 226 Ra and 3 H in order to allow the use of the 222 Rn and 3 He methods. While these studies give broadly concordant results, many questions remain unanswered. The wind velocity dependence of gas exchange rate has yet to be established in field studies. The dependence of gas exchange rate on molecular diffusivity also remains in limbo. Finally, the degree of enhancement of CO 2 exchange through chemical reactions has been only partially explored. 49 references, 2 figures, 2 tables

  4. The GLAS Algorithm Theoretical Basis Document for Laser Footprint Location (Geolocation) and Surface Profiles

    Science.gov (United States)

    Shutz, Bob E.; Urban, Timothy J.

    2014-01-01

    This ATBD summarizes (and links with other ATBDs) the elements used to obtain the geolocated GLAS laser spot location, with respect to the Earth Center of Mass. Because of the approach used, the reference frame used to express the geolocation is linked to the reference frame used for POD and PAD, which are related to the ITRF. The geolocated spot coordinates (which includes the elevation or height, with respect to an adopted reference ellipsoid) is the inferred position of the laser spot, since the spot location is not directly measured. This document also summarizes the GLAS operation time periods.

  5. Composition and structure of Si-doped NiTi with a complex surface profile

    Science.gov (United States)

    Slabodchikov, Vladimir A.; Ovchinnikov, Stanislav V.; Kuznetsov, Vladimir M.

    2017-12-01

    The paper presents Auger spectroscopy and electron microscopy data on the elemental composition and structure of NiTi specimens with blind holes doped with Si through plasma immersion ion implantation. The data demonstrate how silicon is distributed through the depth of NiTi from its front surface and along the side of its hole. The upper layer formed upon treatment is shown to be amorphous, and its thickness measuring several tens of nanometers is about two times larger on the side surface of the hole than on the front surface.

  6. Measuring Systems Interoperability: Challenges and Opportunities

    National Research Council Canada - National Science Library

    Kasunic, Mark; Anderson, William

    2004-01-01

    Interoperability is the ability of systems, units, or forces to provide services to and accept services from other systems, units, or forces and to use the services exchanged to enable them to operate...

  7. GRIP DC-8 METEOROLOGICAL MEASUREMENT SYSTEM (MMS) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP DC-8 Meteorological measurement System (MMS) dataset was collected by the Meteorological Measurement System (MMS), which provides high-resolution, accurate...

  8. Surface profiling of lithium with a laser-desorption mass-spectrometer microprobe

    International Nuclear Information System (INIS)

    Bickel, G.A.; Adams, H.M.

    1999-01-01

    A laser-desorption mass-spectrometer microprobe has been developed to profile Li distributions on the crevice surfaces of Cr-plated rolled-joint hubs. A single laser pulse is used to desorb and ionize the surface species followed by detection of Li + in a time-of-flight mass spectrometer. Images of the surface Li distribution are obtained with are solution of <10 μm. These images are directly compared with Li images from the more conventional secondary ion mass spectrometry technique and evaluated with respect to surface topographical features measured by secondary electron microscopy and atomic force microscopy. The laser-desorption images are shown to provide the same qualitative information as that available from secondary ion mass spectrometry. (author)

  9. Highly sensitive straightness measurement system using a ball-lens

    International Nuclear Information System (INIS)

    Lee, Minho; Yang, Hyun-Ik; Cho, Nahm-Gyoo

    2016-01-01

    In this paper, a new and simple optical technique to accurately measure the straightness errors of a linear stage is proposed. To improve the performance, including the measurement sensitivity and resolution of the measurement system, and to simultaneously measure two-dimensional straightness errors (2D straightness errors), an optical system was designed using a laser, a retro-reflector, a ball-lens, and a two-dimensional position sensitive detector (2D PSD). The characteristics of the measurement system were analytically and experimentally investigated. A prototype measurement system was manufactured based on the investigated results, and the performances of this system have been tested. The measuring performance of the system was easily improved by about 12 times using the proposed technique and it can be further improved. It is shown that the proposed technique can easily and effectively improve the performance of a conventional straightness measurement system based on the geometric optical method using a PSD. (paper)

  10. PLS beam position measurement and feedback system

    International Nuclear Information System (INIS)

    Huang, J.Y.; Lee, J.; Park, M.K.; Kim, J.H.; Won, S.C.

    1992-01-01

    A real-time orbit correction system is proposed for the stabilization of beam orbit and photon beam positions in Pohang Light Source. PLS beam position monitoring system is designed to be VMEbus compatible to fit the real-time digital orbit feedback system. A VMEbus based subsystem control computer, Mil-1553B communication network and 12 BPM/PS machine interface units constitute digital part of the feedback system. With the super-stable PLS correction magnet power supply, power line frequency noise is almost filtered out and the dominant spectra of beam obtit fluctuations are expected to appear below 15 Hz. Using DSP board in SCC for the computation and using an appropriate compensation circuit for the phase delay by the vacuum chamber, PLS real-time orbit correction system is realizable without changing the basic structure of PLS computer control system. (author)

  11. Probing the surface profile and friction behavior of heterogeneous polymers: a molecular dynamics study

    Science.gov (United States)

    Dai, L.; Sorkin, V.; Zhang, Y. W.

    2017-04-01

    We perform molecular dynamics simulations to investigate molecular structure alternation and friction behavior of heterogeneous polymer (perfluoropolyether) surfaces using a nanoscale probing tip (tetrahedral amorphous carbon). It is found that depending on the magnitude of the applied normal force, three regimes exist: the shallow depth-sensing (SDS), deep depth-sensing (DDS), and transitional depth-sensing (TDS) regimes; TDS is between SDS and DDS. In SDS, the tip is floating on the polymer surface and there is insignificant permanent alternation in the polymer structure due to largely recoverable atomic deformations, and the surface roughness profile can be accurately measured. In DDS, the tip is plowing through the polymer surface and there is significant permanent alternation in the molecular structure. In this regime, the lateral friction force rises sharply and fluctuates violently when overcoming surface pile-ups. In SDS, the friction can be described by a modified Amonton’s law including the adhesion effect; meanwhile, in DDS, the adhesion effect is negligible but the friction coefficient is significantly higher. The underlying reason for the difference in these regimes rests upon different contributions by the repulsion and attraction forces between the tip and polymer surfaces to the friction force. Our findings here reveal important insights into lateral depth-sensing on heterogeneous polymer surfaces and may help improve the precision of depth-sensing devices.

  12. Center of mass movement estimation using an ambulatory measurement system

    NARCIS (Netherlands)

    Schepers, H. Martin; van Asseldonk, Edwin H.F.; Buurke, Jaap; Veltink, Petrus H.; Bussmann, J.B.J; Horemans, H.L.D.; Hurkmans, H.L.P.

    2008-01-01

    Human body movement analysis is done in so-called 'gait-laboratories' where several gait variables are estimated by measurement systems such as optical position measurement systems, EMG or force plates. The accuracy of the ambulatory system is verified by comparing it to an optical reference system

  13. Power system observability with minimum phasor measurement ...

    African Journals Online (AJOL)

    The OPP methodologies applied include the system observablility during normal operating conditions, as well as during single branch forced outages. In order to improve the speed of convergence, an initial PMU placement is provided by graph-theoretic procedure. The IEEE 14-bus, 118-bus standard test power systems ...

  14. International Instructional Systems: How England Measures Up

    Science.gov (United States)

    Creese, Brian; Isaacs, Tina

    2016-01-01

    Although England was not included in the International Instructional Systems Study because it was not a high-performing jurisdiction by the Study's definition, contributors largely were England-based. Analysing the Study's nine overall aspects of instructional systems, this paper finds that England is out of step with many of the high-performing…

  15. Methods and systems for measuring anions

    KAUST Repository

    Masih, Dilshad

    2016-08-18

    Embodiments of the present disclosure provide for methods for detecting the presence and/or concentration of anions in a solution, systems for detecting the presence and/or concentration of anions in a solution, anion sensor systems, and the like.

  16. Analysis of reliability parameters for complicated information measurement systems

    OpenAIRE

    Sydor, Andriy

    2012-01-01

    A method of analysis of reliability parameters for complicated systems by means of generating functions is developed taking account of aging of the systems output elements. Main reliability parameters of complicated information measurement systems are examined in this paper.

  17. NAMMA DC-8 METEOROLOGICAL MEASUREMENT SYSTEM (MMS) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The MMS consists of three major systems: an air-motion sensing system to measure air velocity with respect to the aircraft, an aircraft-motion sensing system to...

  18. Distributed Force and Moment Measurement System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The structural design of aircraft and their propulsion systems is a challenging task that requires accurate, flexible ground facilities capable of operating over the...

  19. Multichannel system for angular distribution measurements

    International Nuclear Information System (INIS)

    Burjan, V.; Kroha, V.; Putz, K.

    A description is given of the individual blocks of the spectrometric apparatus used for measuring the angular distribution of particle spectra and excitation functions of (d,p) reactions at an electrostatic accelerator and the U-120 M cyclotron, both operating at the Nuclear Physics Institute of the Czechoslovak Academy of Sciences at Rez. Main attention was devoted to attaining maximum energy resolution at a high measurement efficiency, this by installing 8 independent spectrometric chains allowing simultaneous measurement of angular distribution in 8 points of the beam. The semiconductor detectors were cooled to -40 degC to -60 degC, which significantly reduced the level of inherent detector noise. An energy resolution of 13 keV was attained using Tesla detectors at a particle energy of 11 MeV. A brief review of data processing and software is given. (B.S.)

  20. Design of MEMS accelerometer based acceleration measurement system for automobiles

    Science.gov (United States)

    Venkatesh, K. Arun; Mathivanan, N.

    2012-10-01

    Design of an acceleration measurement system using a MEMS accelerometer to measure acceleration of automobiles in all the three axes is presented. Electronic stability control and anti-lock breaking systems in automobiles use the acceleration measurements to offer safety in driving. The system uses an ARM microcontroller to quantize the outputs of accelerometer and save the measurement data on a microSD card. A LabVIEW program has been developed to analyze the longitudinal acceleration measurement data and test the measurement system. Random noises generated and added with measurement data during measurement are filtered by a Kalman filter implemented in LabVIEW. Longitudinal velocity of the vehicle is computed from the measurement data and displayed on a graphical chart. Typical measurement of velocity of a vehicle at different accelerations and decelerations is presented.

  1. Surface Moisture Measurement System Operation and Maintenance Manual

    International Nuclear Information System (INIS)

    Ritter, G.A.; Pearce, K.L.; Stokes, T.L.

    1995-12-01

    This operations and maintenance manual addresses deployment, equipment and field hazards, operating instructions, calibration verification, removal, maintenance, and other pertinent information necessary to safely operate and store the Surface Moisture Measurement System (SMMS) and Liquid Observation Well Moisture Measurement System (LOWMMS). These systems were developed primarily in support of Tank Waste Remediation System (TWRS) Safety Programs for moisture measurement in organic and ferrocyanide watch list tanks

  2. Volatility Measurements Applied to Information Systems

    Science.gov (United States)

    2013-09-01

    ABBREVIATIONS CAPM Capital Asset Pricing Model CCOP Cryptologic Carry-On Program CFO Chief Financial Officer CIO Chief Information Officer DCF Discounted...financial markets and the measurement of beta and its relation to volatility. The Capital Asset Pricing Model ( CAPM ) describes the risk and return

  3. Measures of Autonomic Nervous System Regulation

    Science.gov (United States)

    2011-04-01

    Cortisol Galvanic Skin Response (GSR) Gastro- intestinal Pupillary Response Respiratory Salivary Amylase Vascular Manipulative Body-Based...Salivary Amylase Galvanic Skin Response Vascular Gastrointestinal The ANS Measures Table in Appendix A provides a summary of over fifty tools...Subject-to-subject repeatable results reported  Cronbach alpha exceeding 0.70 Validity was assessed by the tool’s ability to quantify the

  4. Creep measurements on curing epoxy systems

    DEFF Research Database (Denmark)

    Kammer, Charlotte; Szabo, Peter

    1998-01-01

    The chemical curing of a stoichiometric mixture of the diglycidyl ether of bisphenol A and a 1,3-bis-(aminomethyl)-cyclohexane is studied.Creep experiments are combined with measurements in a Differential Scanning Calorimeter (DSC) to determine the change in bulk viscosity due to network formation....

  5. Weak measurements in non-Hermitian systems

    Science.gov (United States)

    Matzkin, A.

    2012-11-01

    ‘Weak measurements’—involving a weak unitary interaction between a quantum system and a meter followed by a projective measurement—are investigated when the system has a non-Hermitian Hamiltonian. We show in particular how the standard definition of the ‘weak value’ of an observable must be modified. These studies are undertaken in the context of bound-state scattering theory, a non-Hermitian formalism for which the involved Hilbert spaces are unambiguously defined and the metric operators can be explicitly computed. Numerical examples are given for a model system. This article is part of a special issue of Journal of Physics A: Mathematical and Theoretical devoted to ‘Quantum physics with non-Hermitian operators’.

  6. Development of radiation detection and measurement systems

    Energy Technology Data Exchange (ETDEWEB)

    Moon, B. S.; Ham, C. S.; Chung, C. E. and others

    2000-03-01

    This report contains descriptions on the following six items. The first item is the result of a study on CsI(TI) crystals with their light emitting characteristics and the result of a study on plastic scintillators. The second item is the result of a study on advanced radiation detectors and includes experiments for the effect of using a Compton suppressor with an HPGe detector. For the third item, we describe the results of a design work done using EGS4 for a thickness gauge, a density gauge, and a level gauge. The fourth item contains descriptions on the prototype circuit systems developed for a level gauge, a thickness gauge, and for a survey meter. The fifth part contains the computed tomography algorithm and a prototype scanning system developed for a CT system. As the sixth and the last item, we describe the prototype high precision heat source and the prototype heat-voltage converter which we have designed and fabricated.

  7. Dynamic Measurements of a Novel System

    DEFF Research Database (Denmark)

    Yu, Tao; Zhang, Chen; Heiselberg, Per Kvols

    In the PSO project 345-061, a novel system solution combining natural ventilation with diffuse ceiling inlet and thermally activated building systems (TABS) has been proposed for cooling and ventilation in Danish office buildings. Due to the application of diffuse ceiling inlet, cold outdoor air...... can be supplied into the room without any risk of draught even in the extreme winter. This means that natural ventilation is available even in winter and it is beneficial to reduce the energy consumption for buildings with cooling demand in cold seasons....

  8. Solar energy control system. [temperature measurement

    Science.gov (United States)

    Currie, J. R. (Inventor)

    1981-01-01

    A solar energy control system for a hot air type solar energy heating system wherein thermocouples are arranged to sense the temperature of a solar collector, a space to be heated, and a top and bottom of a heat storage unit is disclosed. Pertinent thermocouples are differentially connected together, and these are employed to effect the operation of dampers, a fan, and an auxiliary heat source. In accomplishing this, the differential outputs from the thermocouples are amplified by a single amplifier by multiplexing techniques. Additionally, the amplifier is corrected as to offset by including as one multiplex channel a common reference signal.

  9. The Strategic Systems Therapies: Measuring the Models.

    Science.gov (United States)

    Rohrbaugh, Michael

    As family therapy becomes a serious intellectual disipline, the relationships among its leading variations require closer examination. To examine similarities and differences among four closely related approaches (brief, problem-focused therapy; structural family therapy; strategic family therapy; and systemic family therapy) and to determine if…

  10. Measuring healthcare productivity - from unit to system level.

    Science.gov (United States)

    Kämäräinen, Vesa Johannes; Peltokorpi, Antti; Torkki, Paulus; Tallbacka, Kaj

    2016-04-18

    Purpose - Healthcare productivity is a growing issue in most Western countries where healthcare expenditure is rapidly increasing. Therefore, accurate productivity metrics are essential to avoid sub-optimization within a healthcare system. The purpose of this paper is to focus on healthcare production system productivity measurement. Design/methodology/approach - Traditionally, healthcare productivity has been studied and measured independently at the unit, organization and system level. Suggesting that productivity measurement should be done in different levels, while simultaneously linking productivity measurement to incentives, this study presents the challenges of productivity measurement at the different levels. The study introduces different methods to measure productivity in healthcare. In addition, it provides background information on the methods used to measure productivity and the parameters used in these methods. A pilot investigation of productivity measurement is used to illustrate the challenges of measurement, to test the developed measures and to prove the practical information for managers. Findings - The study introduces different approaches and methods to measure productivity in healthcare. Practical implications - A pilot investigation of productivity measurement is used to illustrate the challenges of measurement, to test the developed measures and to prove the practical benefits for managers. Originality/value - The authors focus on the measurement of the whole healthcare production system and try to avoid sub-optimization. Additionally considering an individual patient approach, productivity measurement is examined at the unit level, the organizational level and the system level.

  11. Improved Measurement System for Atmospheric Studies

    Science.gov (United States)

    2015-05-05

    5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 5c. PROGRAM ELEMENT NUMBER 5b. GRANT NUMBER 5a. CONTRACT NUMBER Form Approved OMB NO...undergraduates funded by your agreement who graduated during this period and intend to work for the Department of Defense The number of undergraduates...The high sensitivity of the TLS turbulence measurements is ideally suited for operation in the low turbulence regimes that characterize nocturnal

  12. Overhead traveling crane vibration research using experimental wireless measuring system

    Directory of Open Access Journals (Sweden)

    Tomasz HANISZEWSKI

    2013-01-01

    Full Text Available The paper contains an operations and constructions description of theexperimental wireless measuring system for measuring accelerations in bridge cranes,based on PHIDGET 1056 sensors. Developed experimental research and measuringmethodology allows the use of the proposed wireless system on other cranesconstructions. The paper also shows examples of the results of vibration measurementsand FFT spectra, obtained on the basis of accelerations measurements.

  13. Automatic measurement system for light element isotope analysis

    International Nuclear Information System (INIS)

    Satake, Hiroshi; Ikegami, Kouichi.

    1990-01-01

    The automatic measurement system for the light element isotope analysis was developed by installing the specially designed inlet system which was controlled by a computer. The microcomputer system contains specific interface boards for the inlet system and the mass spectrometer, Micromass 602 E. All the components of the inlet and the computer system installed are easily available in Japan. Ten samples can be automatically measured as a maximum of. About 160 minutes are required for 10 measurements of δ 18 O values of CO 2 . Thus four samples can be measured per an hour using this system, while usually three samples for an hour using the manual operation. The automatized analysis system clearly has an advantage over the conventional method. This paper describes the details of this automated system, such as apparatuses used, the control procedure and the correction for reliable measurement. (author)

  14. Computerized x-ray radiographic system for fuel pellet measurements

    International Nuclear Information System (INIS)

    Green, D.R.; Karnesky, R.A.; Bromley, C.

    1977-01-01

    The development and operation of a computerized system for determination of fuel pellet diameters from x-ray radiography is described. Actual fuel pellet diameter measurements made with the system are compared to micrometer measurements on the same pellets, and statistically evaluated. The advantages and limitations of the system are discussed, and recommendations are made for further development

  15. The Entropy Theoretic Measure for Manpower Systems in Perspective

    African Journals Online (AJOL)

    This study provides a realistic appraisal of the use of entropy measures in manpower systems. The appraisal shows that the existing entropy measures for manpower systems give a partial picture of the behavioural mechanism of the system. Consequent upon this, we propose the use of transition probabilities of the ...

  16. Development of radiation measurement system for irradiated gemstones

    International Nuclear Information System (INIS)

    Kornduangkaeo, Areeratt; Kajornrith, Varavuth; Pongkasem, Somchai; Punyanut, Adisak; Maneewong, Apichate; Kbooncham, Kanchana; Salaemae, Nuhayatee; Puchsaka, Jinnawat; Srihera, Porames; Adwichai, Watcharee

    2007-08-01

    Full text: The objective of this research study was to develop the radiation measurement system for irradiated gemstones by using the automatic sample changer with hole-through NaI(Tl) detector compared to HPGe detector. The result showed that measuring time for the new system is less than 100 times HPGe detector. The accuracy of the system is 4-10%

  17. New Protective Measures for Cooling Systems

    International Nuclear Information System (INIS)

    Carter, D. Anthony; Nonohue, Jonh M.

    1974-01-01

    Cooling water treatments have been updated and improved during the last few years. Particularly important are the nontoxic programs which conform plant cooling water effluents to local water quality standards without expenditures for capital equipment. The relationship between scaling and corrosion in natural waters has been recognized for many years. This relationship is the basis for the Langelier Saturation Index control method which was once widely applied to reduce corrosion in cooling water systems. It used solubility characteristics to maintain a very thin deposit on metal surfaces for preventing corrosion. This technique was rarely successful. That is, the solubility of calcium carbonate and most other inorganic salts depends on temperature. If good control exists on cold surfaces, excessive deposition results on the heat transfer tubes. Also, because water characteristic normally vary in a typical cooling system, precise control of scaling at both hot and cold surfaces is virtually impossible

  18. Surface profile gradient in amorphous Ta{sub 2}O{sub 5} semi conductive layers regulates nanoscale electric current stability

    Energy Technology Data Exchange (ETDEWEB)

    Cefalas, A.C., E-mail: ccefalas@eie.gr [National Hellenic Research Foundation, Theoretical and Physical Chemistry Institute, 48 Vassileos Constantinou Avenue, Athens 11635 (Greece); Kollia, Z.; Spyropoulos-Antonakakis, N.; Gavriil, V. [National Hellenic Research Foundation, Theoretical and Physical Chemistry Institute, 48 Vassileos Constantinou Avenue, Athens 11635 (Greece); Christofilos, D.; Kourouklis, G. [Physics Division, School of Technology, Aristotle University of Thessaloniki, Thessaloniki 54124 (Greece); Semashko, V.V.; Pavlov, V. [Kazan Federal University, Institute of Physics, 18 Kremljovskaja str., Kazan 420008 (Russian Federation); Sarantopoulou, E. [National Hellenic Research Foundation, Theoretical and Physical Chemistry Institute, 48 Vassileos Constantinou Avenue, Athens 11635 (Greece); Kazan Federal University, Institute of Physics, 18 Kremljovskaja str., Kazan 420008 (Russian Federation)

    2017-02-28

    Highlights: • The work links the surface morphology of amorphous semiconductors with both their electric-thermal properties and current stability at the nanoscale (<1 μm). • Measured high correlation value between surface morphological spatial gradient and conductive electron energy spatial gradient or thermal gradient. • Unidirectional current stability is associated with asymmetric nanodomains along nanosize conductive paths. • Bidirectional current stability is inherent with either long conductive paths or nanosize conductive paths along symmetric nanodomains. • Conclusion: Surface design improves current stability across nanoelectonic junctions. - Abstract: A link between the morphological characteristics and the electric properties of amorphous layers is established by means of atomic, conductive, electrostatic force and thermal scanning microscopy. Using amorphous Ta{sub 2}O{sub 5} (a-Ta{sub 2}O{sub 5}) semiconductive layer, it is found that surface profile gradients (morphological gradient), are highly correlated to both the electron energy gradient of trapped electrons in interactive Coulombic sites and the thermal gradient along conductive paths and thus thermal and electric properties are correlated with surface morphology at the nanoscale. Furthermore, morphological and electron energy gradients along opposite conductive paths of electrons intrinsically impose a current stability anisotropy. For either long conductive paths (L > 1 μm) or along symmetric nanodomains, current stability for both positive and negative currents i is demonstrated. On the contrary, for short conductive paths along non-symmetric nanodomains, the set of independent variables (L, i) is spanned by two current stability/intability loci. One locus specifies a stable state for negative currents, while the other locus also describes a stable state for positive currents.

  19. Measurement system performance during cold checkout runs at the BNFP

    International Nuclear Information System (INIS)

    Ehinger, M.H.; Crawford, J.M.

    1978-01-01

    The measurement systems in a complex nuclear fuel plant such as the Barnwell Nuclear Fuel Plant rely on capabilities to remotely measure solution quantities and determine the nuclear material content of these solutions. During recent testing activities using natural uranium, a major objective of the NMC group was to demonstrate these solution measurement capabilities. Installed measurement systems at the BNFP use the most recent innovations in measurement equipment and techniques for remote solution measurement. This paper presents the measurement methods and results of the tests and evaluations. 6 figures

  20. Leak rate measurements and detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.; Shack, W.J.; Claytor, T.

    1984-01-01

    A research program is under way at the Argonne National Laboratory under the sponsorship of the USNRC Office of Nuclear Regulatory Research to evaluate and develop improved leak detection systems. The primary focus of the work has been on acoustic emission detection of leaks. Leaks from artificial flaws, laboratory-generated IGSCCs and thermal fatigue cracks, and field-induced intergranular stress corrosion cracks (IGSCCs) from reactor piping have been examined. The effects of pressure, temperature, and leak rate and geometry on the acoustic signature are under study. The use of cross-correlation techniques for leak location and pattern recognition and autocorrelation for source discrimination is also being considered

  1. Measuring the sustainability of energy systems

    International Nuclear Information System (INIS)

    Kroger, W.

    2001-01-01

    Today's energy policies are characterised by a contradictory position. In theory, there is a clear will to respond to emerging threats, e.g. evidence of man-made climate change, irresponsible use of limited resources, geopolitical discrepancies with unbalanced satisfaction of vital needs. In practice, decision making is dominated by economic competitiveness and maximization of short-term profit. The use of fossil fuels is unbroken and still increasing. A recent Green Paper concluded that the EU countries have to reduce growing structural weaknesses by limiting dependence on fuel imports and to give priority to energy systems that do not emit global warming gases. (authors)

  2. Measuring the mass distribution in stellar systems

    Science.gov (United States)

    Tremaine, Scott

    2018-03-01

    One of the fundamental tasks of dynamical astronomy is to infer the distribution of mass in a stellar system from a snapshot of the positions and velocities of its stars. The usual approach to this task (e.g., Schwarzschild's method) involves fitting parametrized forms of the gravitational potential and the phase-space distribution to the data. We review the practical and conceptual difficulties in this approach and describe a novel statistical method for determining the mass distribution that does not require determining the phase-space distribution of the stars. We show that this new estimator out-performs other distribution-free estimators for the harmonic and Kepler potentials.

  3. CAMEX-3 DC-8 METEOROLOGICAL MEASUREMENT SYSTEM (MMS) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-3 Meteorological Measurement System (MMS) dataset consists of atmospheric parameters measured by the MMS instruments aboard NASA DC-8 aircraft. The MMS...

  4. Airport Visibility Measuring Systems Elements of Deployment Cost Analysis

    Science.gov (United States)

    1976-09-01

    This report analyzes the deployment cost for different visibility measuring systems necessary to satisfy CAT I, II, and II operations. The analysis is based on airport operational requirements and data for commercially available visibility measuring ...

  5. A Raspberry Pi Based Portable Endoscopic 3D Measurement System

    Directory of Open Access Journals (Sweden)

    Jochen Schlobohm

    2016-07-01

    Full Text Available Geometry measurements are very important to monitor a machine part’s health and performance. Optical measurement system have several advantages for the acquisition of a parts geometry: measurement speed, precision, point density and contactless operation. Measuring parts inside of assembled machines is also desirable to keep maintenance cost low. The Raspberry Pi is a small and cost efficient computer that creates new opportunities for compact measurement systems. We have developed a fringe projection system which is capable of measuring in very limited space. A Raspberry Pi 2 is used to generate the projection patterns, acquire the image and reconstruct the geometry. Together with a small LED projector, the measurement system is small and easy to handle. It consists of off-the-shelf products which are nonetheless capable of measuring with an uncertainty of less than 100 μ m .

  6. Multi-channel temperature measurement system for automotive battery stack

    Science.gov (United States)

    Lewczuk, Radoslaw; Wojtkowski, Wojciech

    2017-08-01

    A multi-channel temperature measurement system for monitoring of automotive battery stack is presented in the paper. The presented system is a complete battery temperature measuring system for hybrid / electric vehicles that incorporates multi-channel temperature measurements with digital temperature sensors communicating through 1-Wire buses, individual 1-Wire bus for each sensor for parallel computing (parallel measurements instead of sequential), FPGA device which collects data from sensors and translates it for CAN bus frames. CAN bus is incorporated for communication with car Battery Management System and uses additional CAN bus controller which communicates with FPGA device through SPI bus. The described system can parallel measure up to 12 temperatures but can be easily extended in the future in case of additional needs. The structure of the system as well as particular devices are described in the paper. Selected results of experimental investigations which show proper operation of the system are presented as well.

  7. Moire interferometry and hole drilling system for residual stress measurement

    Science.gov (United States)

    Ya, Min; Dai, Fulong; Lu, Jian

    2003-04-01

    A combined system of four beams moire interferometer and incremental hole-driling machine was designed and applied for residual stress measurement. Two typical experiments were done using this system: non-uniform in-depth residual stress measurement of an ultrasonic shot-peening Aluminum plate; non-uniform in-plane residual stress measurement of an elastic-plastic Aluminum bent beam. Experiments results show good accordant with other measurement results and theory analysis results.

  8. Measurement of resilience and its application to enterprise information systems

    Science.gov (United States)

    Wang, J. W.; Gao, F.; Ip, W. H.

    2010-05-01

    In this article, we present a measure for resilience in the context of enterprise information systems or service systems in a more general sense. Resilience of the system is a property of the system, which focuses on the recovery ability of the system after a partial damage of the system. Enterprise information systems such as enterprise resource planning, supply chain management, customer relationship management, manufacturing execution system, etc. play a critical role in the daily operation of modern enterprises by timely and sustainable delivery of information. Therefore, resilience is especially important for the enterprise information systems. The proposed measure for resilience is based on the recovery ability of the system, which departs from the existing approaches in literature and presents a unique contribution. An example is given to illustrate how the proposed measure works.

  9. Application of virtual instrument in accelerator beam measurement system

    International Nuclear Information System (INIS)

    Huang Guoqing; China Science and Technology Univ., Hefei; Yu Xiaoqi; Zhang Pengfei

    2007-01-01

    Virtual instrument is a novel computer-based technical method of measurement, which has got rapidly development and has been applied in many fields because of a variety of advantages. In this paper we mainly introduce application of virtual instrument in accelerator beam measurement system. Beam measurement system is an important part of accelerator technology and has important effect on accelerator debugging, running and machine research. Adopting new measurement methods and increasing accuracy of measurement directly affect accelerator debugging and running. Now many accelerators have been adopted virtual instrument system. (authors)

  10. Radiation internal exposure measurements archiving system (REMAS)

    International Nuclear Information System (INIS)

    Bitar, A.; Maghrabi, M.

    2013-01-01

    This paper describes a personal-computer-based software, REMAS, which helps users to estimate intake activity and resulting internal doses for all radionuclides existing in (International Commission on Radiological Protection) ICRP 78 and other important elements. In addition to its use in internal dose calculations, it facilitates management of data of monitored persons who are occupationally exposed to unsealed radioactive substances. Furthermore, REMAS offers the possibility to generate different reports of results. The program is suitable for laboratories working in the field of assessment of occupational intake and also for users of radioactive material who are routinely monitored. REMAS, which is bilingual program (English and Arabic), was built with GUI environment and was developed using Microsoft FoxPro. It runs on Microsoft Windows XP operating systems. (authors)

  11. [An integrated system of blood pressure measurement with bluetooth communication].

    Science.gov (United States)

    Wang, Wei; Wang, Jing; Sun, Hongyang; Xu, Zuyang; Chai, Xinyu

    2012-07-01

    The development of the integrated blood pressure system with bluetooth communication function is introduced. Experimental results show that the system can complete blood pressure measurement and data transmission wireless effectively, which can be used in m-Health in future.

  12. Competitiveness measurement system in the advertising sector.

    Science.gov (United States)

    Poveda-Bautista, Rocío; García-Melón, Mónica; Baptista, Doris C

    2013-01-01

    In this paper a new approach to find indicators that can be used to measure companies' competitiveness and performance in an efficient and reliable way is presented. The aim is to assist managers of companies within a specific industrial sector by providing information about their relative position in the market so as to define better action plans that may improve the company's performance. The approach combines the use of the Analytic Network Process, a multicriteria decision method, with the Balanced Scorecard. It allows the definition of a number of competitiveness indicators based on the performance and setting of the advertising sector. In this way it is possible to obtain a Competitiveness Index that allows a company to know its relative position with respect to other companies in the sector, and establish a ranking of the companies ordered by their competitiveness level. A case study in the advertising industry of Venezuela is provided. Results show that improvement plans for the agencies analyzed should promote creativity, innovation and the use of new technologies, as a particular form of innovation. These factors were considered to be the most relevant indicators in the advertising sector. The participating experts agreed that the methodology is useful and an improvement over current competitiveness assessment methods.

  13. New measuring and protection system at VR-1 training reactor

    International Nuclear Information System (INIS)

    Kropik, M.; Jurickova, M.

    2006-01-01

    The contribution describes the new measuring and protection system of the VR-1 training reactor. The measuring and protection system upgrade is an integral part of the reactor I and C upgrade. The new measuring and protection system of the VR-1 reactor consists of the operational power measuring and the independent power protection systems. Both systems measure the reactor power and power rate, initiate safety action if safety limits are exceeded and send data (power, power rate, status, etc.) to the reactor control system. The operational power measuring system is a full power range system that receives signal from a fission chamber. The signal is evaluated according to the reactor power either in the pulse or current mode. The current mode utilizes the DC current and Campbell techniques. The new independent power protection system operates in the two highest reactor power decades. It receives signals from a boron chamber and evaluates it in the pulse mode. Both systems are computer based. The operational power measuring and independent power protection systems are diverse - different types and location of chambers, completely different hardware, software algorithms for the power and power rate calculations, software development tools and teems for the software manufacturing. (author)

  14. Integrated optical measurement system for fluorescence spectroscopy in microfluidic channels

    DEFF Research Database (Denmark)

    Hübner, Jörg; Mogensen, Klaus Bo; Jørgensen, Anders Michael

    2001-01-01

    A transportable miniaturized fiber-pigtailed measurement system is presented which allows quantitative fluorescence detection in microliquid handling systems. The microliquid handling chips are made in silica on silicon technology and the optical functionality is monolithically integrated...... with the microfluidic channel system. This results in inherent stability and photolithographic alignment precision. Permanently attached optical fibers provide a rugged connection to the light source, detection, and data processing unit, which potentially allows field use of such systems. Fluorescence measurements...

  15. Design techniques for large scale linear measurement systems

    International Nuclear Information System (INIS)

    Candy, J.V.

    1979-03-01

    Techniques to design measurement schemes for systems modeled by large scale linear time invariant systems, i.e., physical systems modeled by a large number (> 5) of ordinary differential equations, are described. The techniques are based on transforming the physical system model to a coordinate system facilitating the design and then transforming back to the original coordinates. An example of a three-stage, four-species, extraction column used in the reprocessing of spent nuclear fuel elements is presented. The basic ideas are briefly discussed in the case of noisy measurements. An example using a plutonium nitrate storage vessel (reprocessing) with measurement uncertainty is also presented

  16. Efficiency criteria for high reliability measured system structures

    International Nuclear Information System (INIS)

    Sal'nikov, N.L.

    2012-01-01

    The procedures of structural redundancy are usually used to develop high reliability measured systems. To estimate efficiency of such structures the criteria to compare different systems has been developed. So it is possible to develop more exact system by inspection of redundant system data unit stochastic characteristics in accordance with the developed criteria [ru

  17. Measuring Isotope Ratios Across the Solar System

    Science.gov (United States)

    Webster, Chris R.; Mahaffy, Paul R.

    2012-01-01

    Stable isotope ratios in C, H, N, O and S are powerful indicators of a wide variety of planetary geophysical processes that can identify origin, transport, temperature history, radiation exposure, atmospheric escape, environmental habitability and biology [1]. For the Allan Hills 84001 meteorite, for example, the (sup 1)(sup 3)C/(sup 1)(sup 2)C ratio identifies it as a Mars (SNC) meteorite; the ??K/??Ar ratio tells us the last time the rock cooled to solid, namely 4 Gya; isotope ratios in (sup 3)He, (sup 2)(sup 1)Ne and (sup 3)?Ar show it was in space (cosmic ray exposure) for 10-20 million years; (sup 1)?C dating that it sat in Antarctica for 13,000 years before discovery; and clumped isotope analysis of (sup 1)?O(sup 1)(sup 3)C(sup 1)?O in its carbonate that it was formed at 18+/-4 ?C in a near-surface aqueous environment [2]. Solar System Formation

  18. System for measuring the proton polarization in a polarized target

    International Nuclear Information System (INIS)

    Karnaukhov, I.M.; Lukhanin, A.A.; Telegin, Yu.N.; Trotsenko, V.I.; Chechetenko, V.F.

    1984-01-01

    The system for measuring the proton polarization in a polarized target representing the high-sensitivity nuclear magnetic resonance (NMR) is described Q-meter with series connection and a circuit for measuring system resonance characteristic is used for NMR-absorption signal recording. Measuring coil is produced of a strip conductor in order to obtain uniform system sensitivity to polarization state in all target volume and improve signal-to-noise ratio. Polarization measuring system operates ion-line with the M-6000 computer. The total measuring error for the value of free proton polarization in target taking into account the error caused by local depolarization of working substance under irradiation by high-intense photon beam is <= 6%. Long-term application of the described system for measuring the proton polarization in the LUEh-20000 accelerator target used in the pion photoproduction experiments has demonstrated its high reliability

  19. A novel multipoint measuring system of photosynthetically active radiation

    International Nuclear Information System (INIS)

    Palva, L.; Garam, E.; Manoochehri, F.; Sepponen, R.; Hari, P.; Rajala, K.; Ruotoistenmaki, H.; Seppala, I.

    1998-01-01

    A novel multipoint measuring system of photosynthetically active radiation (PAR) has been designed. It is used as a component of a field measurement system of photosynthesis. The system consists of a multichannel fiberoptic sensor, Intel 486-based microcomputer (PC) with software for control and analysis and interface electronics. The fiberoptic sensor comprises 800 measuring points which are arranged in a regular grid on a plane. This grid is attached to a cuvette to observe the spatial and temporal distribution of PAR falling on the needles along with simultaneous measurements of CO 2 exchange. PAR is registered through a fiberoptic bundle using a charge coupled device (CCD) sensor. The system has been in operation between July and October 1996 within a Scots pine canopy. The results demonstrate that the obtained regression between the photosynthetic rate estimated with the multipoint PAR measuring system and the measured CO 2 exchange rate is as tight within a canopy as in unshaded conditions. (author)

  20. Stretch-dependent changes in surface profiles of the human crystalline lens during accommodation: a finite element study.

    Science.gov (United States)

    Pour, Hooman Mohammad; Kanapathipillai, Sangarapillai; Zarrabi, Khosrow; Manns, Fabrice; Ho, Arthur

    2015-03-01

    A non-linear isotropic finite element (FE) model of a 29-year-old human crystalline lens was constructed to study the effects of various geometrical parameters on lens accommodation. The model simulates dis-accommodation by stretching of the lens and predicts the change in surface profiles of the lens capsule, cortex and nucleus at select states of stretching/accommodation. Multiple regression analysis (MRA) is used to develop a stretch-dependent mathematical model relating the lens sagittal height to the radial position of the lens surface as a function of dis-accommodative stretch. A load analysis is performed to compare the finite element results to empirical results from lens stretcher studies. Using the predicted geometrical changes, the optical response of the whole eye during accommodation was analysed by ray-tracing. Aspects of lens shape change relative to stretch were evaluated, including change in diameter, central thickness and accommodation. Maximum accommodation achieved was 10.29 D. From the multiple regression analysis, the stretch-dependent mathematical model of the lens shape related lens curvatures as a function of lens ciliary stretch well (maximum mean-square residual error 2.5 × 10(-3 ) μm, p < 0.001). The results are compared with those from in vitro studies. The finite element and ray-tracing predictions are consistent with Ex Vivo Accommodation Simulator (EVAS) studies in terms of load and power change versus change in thickness. The mathematical stretch-dependent model of accommodation presented may have utility in investigating lens behaviour at states other than the relaxed or fully accommodated states. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  1. Cell surface profiling using high-throughput flow cytometry: a platform for biomarker discovery and analysis of cellular heterogeneity.

    Directory of Open Access Journals (Sweden)

    Craig A Gedye

    Full Text Available Cell surface proteins have a wide range of biological functions, and are often used as lineage-specific markers. Antibodies that recognize cell surface antigens are widely used as research tools, diagnostic markers, and even therapeutic agents. The ability to obtain broad cell surface protein profiles would thus be of great value in a wide range of fields. There are however currently few available methods for high-throughput analysis of large numbers of cell surface proteins. We describe here a high-throughput flow cytometry (HT-FC platform for rapid analysis of 363 cell surface antigens. Here we demonstrate that HT-FC provides reproducible results, and use the platform to identify cell surface antigens that are influenced by common cell preparation methods. We show that multiple populations within complex samples such as primary tumors can be simultaneously analyzed by co-staining of cells with lineage-specific antibodies, allowing unprecedented depth of analysis of heterogeneous cell populations. Furthermore, standard informatics methods can be used to visualize, cluster and downsample HT-FC data to reveal novel signatures and biomarkers. We show that the cell surface profile provides sufficient molecular information to classify samples from different cancers and tissue types into biologically relevant clusters using unsupervised hierarchical clustering. Finally, we describe the identification of a candidate lineage marker and its subsequent validation. In summary, HT-FC combines the advantages of a high-throughput screen with a detection method that is sensitive, quantitative, highly reproducible, and allows in-depth analysis of heterogeneous samples. The use of commercially available antibodies means that high quality reagents are immediately available for follow-up studies. HT-FC has a wide range of applications, including biomarker discovery, molecular classification of cancers, or identification of novel lineage specific or stem cell

  2. Cell surface profiling using high-throughput flow cytometry: a platform for biomarker discovery and analysis of cellular heterogeneity.

    Science.gov (United States)

    Gedye, Craig A; Hussain, Ali; Paterson, Joshua; Smrke, Alannah; Saini, Harleen; Sirskyj, Danylo; Pereira, Keira; Lobo, Nazleen; Stewart, Jocelyn; Go, Christopher; Ho, Jenny; Medrano, Mauricio; Hyatt, Elzbieta; Yuan, Julie; Lauriault, Stevan; Meyer, Mona; Kondratyev, Maria; van den Beucken, Twan; Jewett, Michael; Dirks, Peter; Guidos, Cynthia J; Danska, Jayne; Wang, Jean; Wouters, Bradly; Neel, Benjamin; Rottapel, Robert; Ailles, Laurie E

    2014-01-01

    Cell surface proteins have a wide range of biological functions, and are often used as lineage-specific markers. Antibodies that recognize cell surface antigens are widely used as research tools, diagnostic markers, and even therapeutic agents. The ability to obtain broad cell surface protein profiles would thus be of great value in a wide range of fields. There are however currently few available methods for high-throughput analysis of large numbers of cell surface proteins. We describe here a high-throughput flow cytometry (HT-FC) platform for rapid analysis of 363 cell surface antigens. Here we demonstrate that HT-FC provides reproducible results, and use the platform to identify cell surface antigens that are influenced by common cell preparation methods. We show that multiple populations within complex samples such as primary tumors can be simultaneously analyzed by co-staining of cells with lineage-specific antibodies, allowing unprecedented depth of analysis of heterogeneous cell populations. Furthermore, standard informatics methods can be used to visualize, cluster and downsample HT-FC data to reveal novel signatures and biomarkers. We show that the cell surface profile provides sufficient molecular information to classify samples from different cancers and tissue types into biologically relevant clusters using unsupervised hierarchical clustering. Finally, we describe the identification of a candidate lineage marker and its subsequent validation. In summary, HT-FC combines the advantages of a high-throughput screen with a detection method that is sensitive, quantitative, highly reproducible, and allows in-depth analysis of heterogeneous samples. The use of commercially available antibodies means that high quality reagents are immediately available for follow-up studies. HT-FC has a wide range of applications, including biomarker discovery, molecular classification of cancers, or identification of novel lineage specific or stem cell markers.

  3. Application research of tune measurement system in Hefei light source

    CERN Document Server

    Sun Bao Gen; Xu Hong Liang; Lu Ping; Wang Jun; Gao Yun Feng; Wang Li; LiuJinYing

    2002-01-01

    The author introduces the measurement and research of some beam parameters using tune measurement system for Hefei Light Source (HLS), which include the betatron tune, beta function, natural chromaticity, corrected chromaticity, and central frequency. Additionally, it also describes the measurement of the influence of DC clearing electrodes on the betatron tune shift and gives some measurement results. The measurement results are compared with the theoretical values and they are in good agreement

  4. System design description for surface moisture measurement system (SMMS)

    Energy Technology Data Exchange (ETDEWEB)

    Vargo, G.F.

    1996-09-23

    The SMMS has been developed to measure moisture in the top few centimeters of tank waste. The SMMS development was initiated by the preliminary findings of SAR-033, and does not necessarily fulfill any established DQO. After the SAR-033 is released, if no significant changes are made, moisture measurements in the organic waste tanks will rapidly become a DQO. The SMMS was designed to be installed in any 4 inch or larger riser, and to allow maximum adjustability for riser lengths, and is used to deploy a sensor package on the waste surface within a 6 foot radius about the azimuth. The first sensor package will be a neutron probe.

  5. Computer controlled scanning systems for quantitative track measurements

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Preston, C.C.; Ruddy, F.H.

    1982-01-01

    The status of three computer cntrolled systems for quantitative track measurements is described. Two systems, an automated optical track scanner (AOTS) and an automated scanning electron microscope (ASEM) are used for scanning solid state track recorders (SSTR). The third system, the emulsion scanning processor (ESP), is an interactive system used to measure the length of proton tracks in nuclear research emulsions (NRE). Recent advances achieved with these systems are presented, with emphasis placed upon the current limitation of these systems for reactor neutron dosimetry

  6. Readiness to adopt a performance measurement system for ...

    African Journals Online (AJOL)

    Readiness to adopt a performance measurement system for substance abuse treatment: Findings from the Service Quality Measures initiative. ... system, findings show that the likelihood of adoption can be further increased through improved provider awareness and enhanced leadership support for this health innovation.

  7. Reporting Systems for Sustainability: What Are They Measuring?

    Science.gov (United States)

    Davidson, Kathryn M.

    2011-01-01

    The dominance of the neoliberal discourse in the sustainability debate has tended to privilege the economy over environment and social dimensions with implications for what is measured by sustainability monitoring systems. Moreover, systems to measure sustainability, including those influenced by neoliberal discourse, lack robust definitions and…

  8. STORM-SEWER FLOW MEASUREMENT AND RECORDING SYSTEM.

    Science.gov (United States)

    Kilpatrick, Frederick A.; Kaehrle, William R.

    1986-01-01

    A comprehensive study and development of instruments and techniques for measuring all components of flow in a storm-sewer drainage system were undertaken by the U. S. Geological Survey under the sponsorship of FHWA. The study involved laboratory and field calibration and testing of measuring flumes, pipe insert meters, weirs, and electromagnetic velocity meters as well as the development and calibration of pneumatic bubbler and pressure transducer head-measuring systems. Tracer dilution and acoustic-flowmeter measurements were used in field verification tests. A single micrologger was used to record data from all the instruments and also to activate on command the electromagnetic velocity meter and tracer dilution systems.

  9. EPOS1 - a multiparameter measuring system to earthquake prediction research

    International Nuclear Information System (INIS)

    Streil, T.; Oeser, V.; Heinicke, J.; Koch, U.; Wiegand, J.

    1998-01-01

    The approach to earthquake prediction by geophysical, geochemical and hydrological measurements is a long and winding road. Nevertheless, the results show a progress in that field (e.g. Kobe). This progress is also a result of a new generation of measuring equipment. SARAD has developed a versatile measuring system (EPOS1) based on experiences and recent results from different research groups. It is able to record selected parameters suitable to earthquake prediction research. A micro-computer system handles data exchange, data management and control. It is connected to a modular sensor system. Sensor modules can be selected according to the actual needs at the measuring site. (author)

  10. Low Value Capacitance Measurement System with Adjustable Lead Capacitance Compensation

    OpenAIRE

    Gautam Sarkar; Anjan Rakshit; Amitava Chatterjee; Kesab Bhattacharya

    2013-01-01

    The present paper describes the development of a low cost, highly accurate low capacitance measurement system that can be used over a range of 0 – 400 pF with a resolution of 1 pF. The range of capacitance may be easily altered by a simple resistance or capacitance variation of the measurement circuit. This capacitance measurement system uses quad two-input NAND Schmitt trigger circuit CD4093B with hysteresis for the measurement and this system is integrated with PIC 18F2550 microcontroller f...

  11. Grid Based Integration Technologies of Virtual Measurement System

    International Nuclear Information System (INIS)

    Zhang, D P; He, L S; Yang, H

    2006-01-01

    This paper presents a novel integrated architecture of measurement system for the new requirements of measurement collaboration, measurement resource interconnection and transparent access etc in the wide-area and across organization in the context of a grid. The complexity of integration on a grid arises from the scale, dynamism, autonomy, and distribution of the measurement resources. The main argument of this paper is that these complexities should be made transparent to the collaborative measurement, via flexible reconfigurable mechanisms and dynamic virtualization services. The paper is started by discussing the integration-oriented measurement architecture which provides collaborative measurement services to distributed measurement resources and then the measurement mechanisms are discussed which implements the transparent access and collaboration of measurement resources by providing protocols, measurement schedule and global data driven model

  12. AMINA-chip : a miniaturized measurement system for ambient ammonia

    NARCIS (Netherlands)

    Timmer, Björn Herman

    2004-01-01

    The development of a miniaturized and integrated measurement system for gaseous ammonia is described in this thesis. The measuring principle, ¿AMINA¿, is an indirect method for selectively measuring ammonia that makes use of pH-transitions, electrolyte conductivity detection and phaseseparating

  13. Rating PV Power and Energy: Cell, Module, and System Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Emery, Keith

    2016-06-02

    A summary of key points related to research-level measurements of current vs. voltage measurement theory including basic PV operation, equivalent circuit, and concept of spectral error; PV power performance including PV irradiance sensors, simulators and commercial and generic I-V systems; PV measurement artifacts, intercomparisons, and alternative rating methods.

  14. Development of Precision Information Measuring System for Ultraviolet Radiation

    Directory of Open Access Journals (Sweden)

    ROSHCHUPKIN, O.

    2014-08-01

    Full Text Available Results of studying the neural network method are presented to reduce the amount of calibration points for the multisensor (MS, in particular for the photodiode. This allows transmitting to the MS individual conversion function and provides the high accuracy of measurement. The structure of synthesized information-measuring system and its measuring channel has created for implementing of the proposed approach. A structural scheme is proposed as well for values transmitting the etalon measures to measuring systems. Its used to determine the errors of photodiodes, as those which are produced for customers. This assures the interchangeability of sensors when using the individual conversion function.

  15. Computer Generated Hologram System for Wavefront Measurement System Calibration

    Science.gov (United States)

    Olczak, Gene

    2011-01-01

    Computer Generated Holograms (CGHs) have been used for some time to calibrate interferometers that require nulling optics. A typical scenario is the testing of aspheric surfaces with an interferometer placed near the paraxial center of curvature. Existing CGH technology suffers from a reduced capacity to calibrate middle and high spatial frequencies. The root cause of this shortcoming is as follows: the CGH is not placed at an image conjugate of the asphere due to limitations imposed by the geometry of the test and the allowable size of the CGH. This innovation provides a calibration system where the imaging properties in calibration can be made comparable to the test configuration. Thus, if the test is designed to have good imaging properties, then middle and high spatial frequency errors in the test system can be well calibrated. The improved imaging properties are provided by a rudimentary auxiliary optic as part of the calibration system. The auxiliary optic is simple to characterize and align to the CGH. Use of the auxiliary optic also reduces the size of the CGH required for calibration and the density of the lines required for the CGH. The resulting CGH is less expensive than the existing technology and has reduced write error and alignment error sensitivities. This CGH system is suitable for any kind of calibration using an interferometer when high spatial resolution is required. It is especially well suited for tests that include segmented optical components or large apertures.

  16. A software system for measuring bubble chamber films on line

    International Nuclear Information System (INIS)

    Blomqvist, G.; Hulth, P.O.

    1974-01-01

    A system has been developed for measuring bubble chamber films on line. This report describes the computer program used in the on-line system. The program guides the operator during the measurements, makes on-line control of the measurement data and produces output data on magnetic tape in a format suitable as input for the geometry programme THRESH. The on-line program is coded in the assembly language OSAS-A used for CDC 8090 computers. (Auth.)

  17. Balanced Scorecard Based Performance Measurement & Strategic Management System

    OpenAIRE

    Permatasari, Paulina

    2006-01-01

    Developing strategy and performance measurement are an integral part of management control system. Making strategic decision about planning and controlling require information regarding how different subunits in organization work. To be effective, performance measurement, both financial and non-financial must motivate manager and employees at different levels to force goal accomplishment and organization strategic. An organization's measurement system strongly affects the behavior of people b...

  18. A comparison of displacement measuring systems for single-axis measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ramsdale, S.J.

    1996-10-01

    This paper discusses an attempt to make a relative comparison of the performance of an ordinary supermicrometer retrofitted with several different displacement measuring systems. The methodology used was a gage repeatability and reproducibility study. The environment, equipment, and operators were held constant in an experimental design that highlights the difference in capability of the various displacement measuring systems.

  19. Implementation and rejection of industrial steam system energy efficiency measures

    International Nuclear Information System (INIS)

    Therkelsen, Peter; McKane, Aimee

    2013-01-01

    Steam systems consume approximately one third of energy applied at US industrial facilities. To reduce energy consumption, steam system energy assessments have been conducted on a wide range of industry types over the course of 5 years through the Energy Savings Assessment (ESA) program administered by the US Department of Energy (US DOE). ESA energy assessments result in energy efficiency measure recommendations that are given potential energy and energy cost savings and potential implementation cost values. Saving and cost metrics that measure the impact recommended measures will have at facilities, described as percentages of facility baseline energy and energy cost, are developed from ESA data and used in analyses. Developed savings and cost metrics are examined along with implementation and rejection rates of recommended steam system energy efficiency measures. Based on analyses, implementation of steam system energy efficiency measures is driven primarily by cost metrics: payback period and measure implementation cost as a percentage of facility baseline energy cost (implementation cost percentage). Stated reasons for rejecting recommended measures are primarily based upon economic concerns. Additionally, implementation rates of measures are not only functions of savings and cost metrics, but time as well. - Highlights: ► We examine uptake/rejection of industrial steam system energy efficiency measures. ► We examine metrics that correspond to uptake/rejection of recommended measures. ► We examine barriers hindering steam system energy efficiency measure implementation. ► Uptake/rejection of steam measures is linked to potential cost metrics. ► Increased uptake of measures and uptake of more costly measures increases with time

  20. Coast-down time measuring system based on photoelectric method

    Science.gov (United States)

    Zhu, Wei-min; Wang, Da-yong; Qi, Fang

    2010-10-01

    Coast-down time measuring system can measure the time when speed values of Chassis Dynamometers for Automobile Emissions Testing change from initial velocity to end velocity under different load in a given speed range. This coast-down time will represent characters of Chassis Dynamometers for Automobile Emissions Testing such as Dynamometer inertia weight, constant load coast-down time, variable load coast-down time, Chassis Dynamometers for Automobile Emissions Testing can be calibrated by comparing these coast-down time with theoretical values. Working principle of coast-down time measuring system is a photoelectric sampler of coast-down time measuring system collects speed values information of Chassis Dynamometers for Automobile Emissions Testing. Then, determine speed values through calculation. When the velocity is equal to initial velocity Vb value, measuring system starts a timer. When speed reaches end velocity Ve value, measuring system stops the timer. So time interval is coast-down time from Vb to Ve. It is obvious that accuracy of coast-down time measurement lies on whether start and end velocity can be judged accurately and determined quickly, whether accuracy of timing can be admitted, and lies on how long these can be done. Coast-down time measuring system with photoelectric sampler proposed in this paper involves all the above factors, as well as improves measurement accuracy of coast-down time.

  1. Practical methods for measuring refrigerant mass distribution inside refrigeration system

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Guoliang; Ma, Xiaokui; Zhang, Ping; Han, Weizhe [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, No. 800 Dongchuan Road, Shanghai 200240 (China); Kasahara, Shinichi; Yamaguchi, Takahiro [Daikin Air-Conditioning R and D Laboratory, Ltd., 1304 Kanaoka-cho, Sakai, Osaka 591-8511 (Japan)

    2009-03-15

    The purpose of this paper is to present methods for measuring refrigerant mass distribution inside a refrigeration system conveniently and accurately. The quasi on-line measurement method (QOMM) was presented for measuring refrigerant mass inside heat exchangers. Compared with the existing liquid nitrogen method (LNM), QOMM can avoid the refrigerant waste and accelerate the measurement process. For measuring refrigerant mass inside the compressor, QOMM was used together with the oil level observation method. The liquid level method (LLM) was used to measure the refrigerant mass inside the accumulator and the receiver. In order to verify the accuracy of the measurement methods, not only the deviation of the measurement method for refrigerant in single component was analyzed, but also the prediction of the total refrigerant charge in an air conditioner was verified. The results showed that the maximal prediction deviation of the refrigerant charge in the whole refrigeration system is 1.7%. (author)

  2. [Scientific information systems: tools for measures of biomedical research impact].

    Science.gov (United States)

    Navarrete Cortés, José; Banqueri Ozáez, Jesús

    2008-12-01

    The present article provides an analysis and description of the use of scientific information systems as instruments to measure and monitor results and investigative activity in biomedicine. Based on the current situation concerning the use and implementation of these systems, we offer a detailed description of the actors of these systems and propose a functional architecture for this class of software. In addition, the instruments that these types of systems offer for the measurement of the impact of the results of research are described in depth, as these instruments can help in decision making. Finally, a selection of national and international scientific information systems are listed and reviewed.

  3. Development of automated measuring system for machining of turbine casings

    International Nuclear Information System (INIS)

    Sakamoto, Hironobu; Otsuka, Shunpei; Niinaga, Yasunori; Arai, Takao.

    1984-01-01

    In the machining of large turbine components, the method of NC machining and measuring and inspection system which can ensure the flexibility and high accuracy are now desired. Stub boring is the large NC machining system developed on the basis of such requirement, and the machining the inside diameter of steam turbine casings can be realized with high efficiency and high accuracy. In this paper, the large NC machining system, the method of centering alignment for casings by utilizing an industrial television, and the automatic measuring system for machining dimensions are described. The reliability of computer-aided assembly system for steam turbines can be thus promoted. (J.P.N.)

  4. A computer-aided surface roughness measurement system

    International Nuclear Information System (INIS)

    Hughes, F.J.; Schankula, M.H.

    1983-11-01

    A diamond stylus profilometer with computer-based data acquisitions/analysis system is being used to characterize surfaces of reactor components and materials, and to examine the effects of surface topography on thermal contact conductance. The current system is described; measurement problems and system development are discussed in general terms and possible future improvements are outlined

  5. Impeachment as an Accountability Measure in a Presidential System ...

    African Journals Online (AJOL)

    The data collected by means of documents and literature indicates that the presidential system has checks and balances as measures to prevent the abuse of power. ... The paper concludes that a political system where systemic corruption prevails will reduce impeachment to a mere instrument of political vendetta.

  6. Design of a mobile hydrological data measurement system

    Science.gov (United States)

    Liu, Yunping; Wang, Tianmiao; Dai, Fenfen

    2017-06-01

    The current hydrological data acquisition is mainly used in the instrument measurement. Instrument measurement equipment is mainly fixed in a certain water area and the device is easy to be lost. In view of a series of problems, the dynamic measurement system is established by the method of unmanned surface vessel and embedded technology, which can realize any positions measurement of a lake. This method has many advantages, such as mobile convenience, saving money and so on.

  7. Radionuclide measuring systems and improved methods of evaluation for the measurement of wear in stationary and mobile systems

    International Nuclear Information System (INIS)

    Lausch, W.

    1976-01-01

    A newly developped flow through measuring unit makes it possible to perform continuous wear measurements on stationary and mobile systems. It was specifically designed for measurements on engine components of passenger cars. For tests of long duration an oil sampling technique was developed. Fully automated measurements are achieved with a sampling device suitable for both stationary and mobile systems. For systems with oil consumption a mathematical model provides for the necessary connection of the loss of wear particles through oil consumption. In certain cases an empirical graphical method can achieve nearly the same results. (orig.) [de

  8. Energy saving and recovery measures in integrated urban water systems

    Science.gov (United States)

    Freni, Gabriele; Sambito, Mariacrocetta

    2017-11-01

    The present paper describes different energy production, recovery and saving measures which can be applied in an integrated urban water system. Production measures are often based on the installation of photovoltaic systems; the recovery measures are commonly based on hydraulic turbines, exploiting the available pressure potential to produce energy; saving measures are based on substitution of old pumps with higher efficiency ones. The possibility of substituting some of the pipes of the water supply system can be also considered in a recovery scenario in order to reduce leakages and recovery part of the energy needed for water transport and treatment. The reduction of water losses can be obtained through the Active Leakage Control (ALC) strategies resulting in a reduction in energy consumption and in environmental impact. Measures were applied to a real case study to tested it the efficiency, i.e., the integrated urban water system of the Palermo metropolitan area in Sicily (Italy).

  9. [A new parameter measurement system for electrosurgery output].

    Science.gov (United States)

    Zhou, Yu; Li, Dianli; Xu, Wendong; Song, Chengli

    2014-04-01

    Accurate measurements of voltage and current from electrosurgery are the basis of development of electrosurgery with feedback function. We, therefore, developed a parameter measurement system based on PC, with high voltage and current from electrosurgery being sensed with transformers, amplified, filtered, transformed into single-ended signals, and then into RMS signals. The root mean square (RMS) signals were transformed into digital signals through DAQ card and the data was processed in PC with Labview. The process included sampling, displaying and storage. The experiment results indicated that the measurement system could measure the output parameters from electrosurgery steadily and correctly so that the development of the system has been successful. It can be the basis of development of embedded parameters measurement system and can provide accurate feedback information for intellectual electrosurgery.

  10. Calibration of the CCD photonic measuring system for railway inspection

    Science.gov (United States)

    Popov, D. V.; Ryabichenko, R. B.; Krivosheina, E. A.

    2005-08-01

    Increasing of traffic speed is the most important task in Moscow Metro. Requirements for traffic safety grow up simultaneously with the speed increasing. Currently for track inspection in Moscow Metro is used track measurement car has built in 1954. The main drawbacks of this system are absence of automated data processing and low accuracy. Non-contact photonic measurement system (KSIR) is developed for solving this problem. New track inspection car will be built in several months. This car will use two different track inspection systems and car locating subsystem based on track circuit counting. The KSIR consists of four subsystems: rail wear, height and track gauge measurement (BFSM); rail slump measurement (FIP); contact rail measurement (FKR); speed, level and car locating (USI). Currently new subsystem for wheel flange wear (IRK) is developed. The KSIR carry out measurements in real-time mode. The BFSM subsystem contains 4 matrix CCD cameras and 4 infrared stripe illuminators. The FIP subsystem contains 4 line CCD cameras and 4 spot illuminators. The FKR subsystem contains 2 matrix CCD cameras and 2 stripe illuminators. The IRK subsystem contains 2 CCD cameras and 2 stripe illuminators. Each system calibration was carried out for their adjustment. On the first step KSIR obtains data from photonic sensors which is valued in internal measurement units. Due to the calibration on the second step non-contact system converts the data to metric measurement system.

  11. ADC's Insertion Devices and Magnetic Measurement Systems Capabilities

    Science.gov (United States)

    Deyhim, A.; Kulesza, J.

    2013-03-01

    In this paper Advance Design Consulting USA, Inc. (ADC) will discuss ADC's major improved capabilities for building Wiggler Insertion Devices, Undulator Planar Devices, Elliptical Polarizing Undulators (EPU), In-Vacuum Undulators (IVU), Cryogenically Cooled in-vacuum Undulators (CPMU), Super Conductive Undulator, and Insertion Device Magnetic Measurement Systems. ADC has designed, built and delivered Insertion Devices and Magnetic Measurement Systems to such facilities as MAX-lab (two EPUs, a Planar, and Measurement System), ALBA and ASP (Wigglers), BNL (CPMU), SSRF (two IVUs and a Measurement System), PAL (one IVU and Measurement System), NSRRC (one 4m EPU), and SRC (Planar and EPU). ADC's magnetic field measurement system is a sophisticated and sensitive machine for the measurement of magnetic fields in undulators (Planar and EPU), wigglers and in-vacuum ID units. The magnetic fields are measured using 3 axis hall-effect probes, mounted orthogonally, to a thin wand. The wand is mounted to a carriage that rides on vacuum air bearings. The base is granite. A flip coil is provided on two vertical towers with X, Y and Theta axes. Special software is provided to assist in homing, movement, and data collection and analysis.

  12. In situ measurement on TSV-Cu deformation with hotplate system based on sheet resistance

    Science.gov (United States)

    Sun, Yunna; Wang, Bo; Wang, Huiying; Wu, Kaifeng; Yang, Shengyong; Wang, Yan; Ding, Guifu

    2017-12-01

    The in situ measurement of TSVs deformation at different temperature is meaningful for learning more about the thermal deformation schemes of 3D TSVs in the microelectronic devices. An efficient and smart hotplate based on sheet resistance is designed for offering more heat, producing a uniform temperature distribution, relieving thermal stress and heat concentration issues, and reducing room space, which was optimized by the finite element method (FEM). The fabricated hotplate is efficient and smart (2.5 cm  ×  2.0 cm  ×  0.5 cm) enough to be located in the limited space during measuring. The thermal infrared imager was employed as the temperature sensor for monitoring the temperature distribution of TSVs sample. The 3D profilometry was adopted as the observer for TSVs profiles survey. The in situ 2D top surface profiles and 3D displacement profiles of TSVs sample at the different temperature were measured by 3D profilometer. The in situ average relative deformation and effective plastic deformation of the TSV sample were measured. With optical measurement method, 3D profilometry, the TSV sample can be tested repeatedly.

  13. Approximate entropy normalized measures for analyzing social neurobiological systems.

    Science.gov (United States)

    Fonseca, Sofia; Milho, João; Passos, Pedro; Araújo, Duarte; Davids, Keith

    2012-01-01

    When considering time series data of variables describing agent interactions in social neurobiological systems, measures of regularity can provide a global understanding of such system behaviors. Approximate entropy (ApEn) was introduced as a nonlinear measure to assess the complexity of a system behavior by quantifying the regularity of the generated time series. However, ApEn is not reliable when assessing and comparing the regularity of data series with short or inconsistent lengths, which often occur in studies of social neurobiological systems, particularly in dyadic human movement systems. Here, the authors present two normalized, nonmodified measures of regularity derived from the original ApEn, which are less dependent on time series length. The validity of the suggested measures was tested in well-established series (random and sine) prior to their empirical application, describing the dyadic behavior of athletes in team games. The authors consider one of the ApEn normalized measures to generate the 95th percentile envelopes that can be used to test whether a particular social neurobiological system is highly complex (i.e., generates highly unpredictable time series). Results demonstrated that suggested measures may be considered as valid instruments for measuring and comparing complexity in systems that produce time series with inconsistent lengths.

  14. Flexible coordinate measurement system based on robot for industries

    Science.gov (United States)

    Guo, Yin; Yang, Xue-you; Liu, Chang-jie; Ye, Sheng-hua

    2010-10-01

    The flexible coordinate measurement system based on robot which is applicable to multi-model vehicle is designed to meet the needs of online measurement for current mainstream mixed body-in-white(BIW) production line. The moderate precision, good flexibility and no blind angle are the benefits of this measurement system. According to the measurement system, a monocular structured light vision sensor has been designed, which can measure not only edges, but also planes, apertures and other features. And a effective way to fast on-site calibration of the whole system using the laser tracker has also been proposed, which achieves the unity of various coordinate systems in industrial fields. The experimental results show satisfactory precision of +/-0.30mm of this measurement system, which is sufficient for the needs of online measurement for body-in-white(BIW) in the auto production line. The system achieves real-time detection and monitoring of the whole process of the car body's manufacture, and provides a complete data support in purpose of overcoming the manufacturing error immediately and accurately and improving the manufacturing precision.

  15. Advanced Active-Magnetic-Bearing Thrust-Measurement System

    Science.gov (United States)

    Imlach, Joseph; Kasarda, Mary; Blumber, Eric

    2008-01-01

    An advanced thrust-measurement system utilizes active magnetic bearings to both (1) levitate a floating frame in all six degrees of freedom and (2) measure the levitation forces between the floating frame and a grounded frame. This system was developed for original use in measuring the thrust exerted by a rocket engine mounted on the floating frame, but can just as well be used in other force-measurement applications. This system offers several advantages over prior thrust-measurement systems based on mechanical support by flexures and/or load cells: The system includes multiple active magnetic bearings for each degree of freedom, so that by selective use of one, some, or all of these bearings, it is possible to test a given article over a wide force range in the same fixture, eliminating the need to transfer the article to different test fixtures to obtain the benefit of full-scale accuracy of different force-measurement devices for different force ranges. Like other active magnetic bearings, the active magnetic bearings of this system include closed-loop control subsystems, through which the stiffness and damping characteristics of the magnetic bearings can be modified electronically. The design of the system minimizes or eliminates cross-axis force-measurement errors. The active magnetic bearings are configured to provide support against movement along all three orthogonal Cartesian axes, and such that the support along a given axis does not produce force along any other axis. Moreover, by eliminating the need for such mechanical connections as flexures used in prior thrust-measurement systems, magnetic levitation of the floating frame eliminates what would otherwise be major sources of cross-axis forces and the associated measurement errors. Overall, relative to prior mechanical-support thrust-measurement systems, this system offers greater versatility for adaptation to a variety of test conditions and requirements. The basic idea of most prior active

  16. Measurement system and model for simultaneously measuring 6DOF geometric errors.

    Science.gov (United States)

    Zhao, Yuqiong; Zhang, Bin; Feng, Qibo

    2017-09-04

    A measurement system to simultaneously measure six degree-of-freedom (6DOF) geometric errors is proposed. The measurement method is based on a combination of mono-frequency laser interferometry and laser fiber collimation. A simpler and more integrated optical configuration is designed. To compensate for the measurement errors introduced by error crosstalk, element fabrication error, laser beam drift, and nonparallelism of two measurement beam, a unified measurement model, which can improve the measurement accuracy, is deduced and established using the ray-tracing method. A numerical simulation using the optical design software Zemax is conducted, and the results verify the correctness of the model. Several experiments are performed to demonstrate the feasibility and effectiveness of the proposed system and measurement model.

  17. Measurement system with high accuracy for laser beam quality.

    Science.gov (United States)

    Ke, Yi; Zeng, Ciling; Xie, Peiyuan; Jiang, Qingshan; Liang, Ke; Yang, Zhenyu; Zhao, Ming

    2015-05-20

    Presently, most of the laser beam quality measurement system collimates the optical path manually with low efficiency and low repeatability. To solve these problems, this paper proposed a new collimated method to improve the reliability and accuracy of the measurement results. The system accuracy controlled the position of the mirror to change laser beam propagation direction, which can realize the beam perpendicularly incident to the photosurface of camera. The experiment results show that the proposed system has good repeatability and the measuring deviation of M2 factor is less than 0.6%.

  18. System security assessment in real-time using synchrophasor measurements

    DEFF Research Database (Denmark)

    Jóhannsson, Hjörtur; Wache, Markus

    2013-01-01

    measures to ensure stable and secure operation of the system are necessary. Time stamped synchrophasor measurements lay the foundation for development of new real-time applications for security and stability assessment. The paper provides overview of existing solutions for synchrophasor based security...... assessment and sheds light on ongoing research activities that focus on exploiting wide-area synchrophasor measurements for real-time security assessment of sustainable power systems. At last, an mathematical mapping enabling informative visualization of the system state in respect to aperiodic rotor angle...

  19. Demonstration of a mobile NDA safeguards measurement system

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Increasing use is being made of nondestructive assay instruments for identification and measurements of nuclear materials. Important advantages of NDA are: timeliness, portability, and ease of use. Recent developments in computer systems and NDA allow for the integration of sample planning, control of NDA, and data analysis into one transportable system. This session acquaints the course participants with the use of mobile NDA safeguards measurement systems. This session considers the practical problems and the type of results that can be expected from field use of NDA instruments. An existing mobile safeguards system will be used to demonstrate some of the differences between field and laboratory conditions. The purpose of the session is to enable participants to: (1) cite the advantages and disadvantages of a mobile NDA safeguards measurement system; (2) identify principal NDA instruments most applicable for use in a mobile system; and (3) identify selected modifications to NDA instruments for field use

  20. Visual Peoplemeter: A Vision-based Television Audience Measurement System

    Directory of Open Access Journals (Sweden)

    SKELIN, A. K.

    2014-11-01

    Full Text Available Visual peoplemeter is a vision-based measurement system that objectively evaluates the attentive behavior for TV audience rating, thus offering solution to some of drawbacks of current manual logging peoplemeters. In this paper, some limitations of current audience measurement system are reviewed and a novel vision-based system aiming at passive metering of viewers is prototyped. The system uses camera mounted on a television as a sensing modality and applies advanced computer vision algorithms to detect and track a person, and to recognize attentional states. Feasibility of the system is evaluated on a secondary dataset. The results show that the proposed system can analyze viewer's attentive behavior, therefore enabling passive estimates of relevant audience measurement categories.

  1. Data acquisition and processing system for coincidence measurements

    International Nuclear Information System (INIS)

    Li Xu

    1990-07-01

    An instrument has been designed for the absolute measurement of radioactivity with 4πβ(PC)-γ coincidence. The instrument can be used as a standard device for the radioactivity measurement in metrology laboratories. Also it can be used in the nuclear science and engineering research for absolute measurement of nuclear decay rate. The control of the system dead time and coincidence resolving time is digitized. The precision can reach ±2 ns. For data acquisition and communication the normalizing GPIB interface system technique is adopted. The measuring error caused by this instrument itself can be better than ±0.02%

  2. On-line pressure measurement using scanning systems

    International Nuclear Information System (INIS)

    Morss, A.G.; Watson, A.P.

    1978-08-01

    Data collection methods can be improved significantly by using pressure scanning systems in conjunction with transducers for the measurement of pressure distribution in fluid flow rigs. However, the response of pressure transducers to the slight random pressure fluctuations that occur in practice can cause some measurement problems, especially for accurate work. The nature of these pressure fluctuations is examined and suitable analysis techniques are recommended. Results obtained using these techniques are presented. It is concluded that by using the correct techniques pressure transducer systems can be used to measure pressure distributions accurately and are sufficiently sensitive to measure very small systematic effects with great precision. (author)

  3. Developing a lean measurement system to enhance process improvement

    Directory of Open Access Journals (Sweden)

    Lewis P.

    2013-01-01

    Full Text Available A key ingredient to underpin process improvement is a robust, reliable, repeatable measurement system. Process improvement activity needs to be supported by accurate and precise data because effective decision making, within process improvement activity, demands the use of “hard” data. One of the oldest and most established process improvement methods is Deming’s Plan-Do-Check-Act (PDCA cycle which is reliant on the check phase, a measurement activity where data is being gathered and evaluated. Recent expansions of the PDCA such as the Six-Sigma Define-Measure-Analyse-Improve-Control (DMAIC methodology place significant importance upon measurement. The DMAIC cycle incorporates the regimented requirement for the inclusion of measurement system analysis (MSA into the breakthrough strategy. The call for MSA within the DMAIC cycle is to provide the improvement activity with a robust measurement system that will ensure a pertinent level of data during any validation process. The Lean methodology is heavily centred on the removal of the seven Mudas (wastes from a manufacturing process: defects, overproduction, transportation, waiting, inventory, motion and processing. The application of lean, particularly within the manufacturing industry, has led to a perception that measurement is a waste within a manufacturing process because measurement processes identify defective products. The metrologists’ pursuit for measurement excellence could be construed as a hindrance by the “cost down” demands being perpetrated from the same organisation’s lean policy. So what possible benefits does enforcing the regimes of the lean and quality philosophies upon the measurement process have and how does this ultimately enhance the process improvement activity? The key fundamental to embed with any process improvement is the removal of waste. The process improvement techniques embedded within lean and quality concepts are extremely powerful practices in the

  4. Machine vision system for measuring conifer seedling morphology

    Science.gov (United States)

    Rigney, Michael P.; Kranzler, Glenn A.

    1995-01-01

    A PC-based machine vision system providing rapid measurement of bare-root tree seedling morphological features has been designed. The system uses backlighting and a 2048-pixel line- scan camera to acquire images with transverse resolutions as high as 0.05 mm for precise measurement of stem diameter. Individual seedlings are manually loaded on a conveyor belt and inspected by the vision system in less than 0.25 seconds. Designed for quality control and morphological data acquisition by nursery personnel, the system provides a user-friendly, menu-driven graphical interface. The system automatically locates the seedling root collar and measures stem diameter, shoot height, sturdiness ratio, root mass length, projected shoot and root area, shoot-root area ratio, and percent fine roots. Sample statistics are computed for each measured feature. Measurements for each seedling may be stored for later analysis. Feature measurements may be compared with multi-class quality criteria to determine sample quality or to perform multi-class sorting. Statistical summary and classification reports may be printed to facilitate the communication of quality concerns with grading personnel. Tests were conducted at a commercial forest nursery to evaluate measurement precision. Four quality control personnel measured root collar diameter, stem height, and root mass length on each of 200 conifer seedlings. The same seedlings were inspected four times by the machine vision system. Machine stem diameter measurement precision was four times greater than that of manual measurements. Machine and manual measurements had comparable precision for shoot height and root mass length.

  5. Calibration Techniques for Accurate Measurements by Underwater Camera Systems.

    Science.gov (United States)

    Shortis, Mark

    2015-12-07

    Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems.

  6. Calibration Techniques for Accurate Measurements by Underwater Camera Systems

    Directory of Open Access Journals (Sweden)

    Mark Shortis

    2015-12-01

    Full Text Available Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems.

  7. Coherent versus Measurement Feedback: Linear Systems Theory for Quantum Information

    Directory of Open Access Journals (Sweden)

    Naoki Yamamoto

    2014-11-01

    Full Text Available To control a quantum system via feedback, we generally have two options in choosing a control scheme. One is the coherent feedback, which feeds the output field of the system, through a fully quantum device, back to manipulate the system without involving any measurement process. The other one is measurement-based feedback, which measures the output field and performs a real-time manipulation on the system based on the measurement results. Both schemes have advantages and disadvantages, depending on the system and the control goal; hence, their comparison in several situations is important. This paper considers a general open linear quantum system with the following specific control goals: backaction evasion, generation of a quantum nondemolished variable, and generation of a decoherence-free subsystem, all of which have important roles in quantum information science. Some no-go theorems are proven, clarifying that those goals cannot be achieved by any measurement-based feedback control. On the other hand, it is shown that, for each control goal there exists a coherent feedback controller accomplishing the task. The key idea to obtain all the results is system theoretic characterizations of the above three notions in terms of controllability and observability properties or transfer functions of linear systems, which are consistent with their standard definitions.

  8. Earth System Research Laboratory Long-Term Surface Aerosol Measurements

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Aerosol measurements began at the NOAA Earth System Research Laboratory (ESRL) Global Monitoring Division (GMD) baseline observatories in the mid-1970's with the...

  9. Differential absorption lidar systems for tropospheric and stratospheric ozone measurements

    Science.gov (United States)

    Mcdermid, I. Stuart; Haner, David A.; Kleiman, Moshe M.; Walsh, T. Daniel; White, Mary L.

    1991-01-01

    A lidar facility has been established at the Jet Propulsion Laboratory-Table Mountain Facility located at an altitude of 2300 m in the San Gabriel Mountains in Southern California. This facility is using the technique of differential absorption lidar to measure atmospheric ozone concentration profiles. Two separate systems are needed to obtain the profile from the ground up to an altitude of 45 to 50 km. An Nd:YAG-based system is described for measurements from the ground up to 15 to 20 km altitude, and an excimer-laser-based system for measurements from 15 km to 45 to 50 km altitude. The systems were designed to make high-precision, long-term measurements to aid in the detection of changes in the atmospheric ozone abundance through participation in the Network of Detection of Stratospheric Change.

  10. Process tomography via sequential measurements on a single quantum system

    CSIR Research Space (South Africa)

    Bassa, H

    2015-09-01

    Full Text Available The authors utilize a discrete (sequential) measurement protocol to investigate quantum process tomography of a single two-level quantum system, with an unknown initial state, undergoing Rabi oscillations. The ignorance of the dynamical parameters...

  11. Real-time personal dose measurement and management system

    International Nuclear Information System (INIS)

    Zhang Zhiyong; Cheng Chang; Liu Zhengshan; Yang Huating; Deng Changming; Zhang Xiu; Guo Zhanjie

    2001-01-01

    The composition and design of a real-time personal dose measurement and management system are described. Accordingly, some pertinent hardware circuits and software codes including their operation modes are presented

  12. Quadratic measurement and conditional state preparation in an optomechanical system

    DEFF Research Database (Denmark)

    A. Brawley, George; Vanner, Michael A.; Bowen, Warwick P.

    2014-01-01

    We experimentally demonstrate, for the first time, quadratic measurement of mechanical motion in an optomechanical system. We use this nonlinear easurement to conditionally prepare classical non-Gaussian states of motion of a micro-mechanical oscillator....

  13. ARTS III Computer Systems Performance Measurement Prototype Implementation

    Science.gov (United States)

    1974-04-01

    Direct measurement of computer systems is of vital importance in: a) developing an intelligent grasp of the variables which affect overall performance; b)tuning the systsem for optimum benefit; c)determining under what conditions saturation threshold...

  14. Oceanographic measurements from the Texas Automated Buoy System (TABS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Texas Automated Buoy System contains daily oceanographic measurements from seven buoys off the Texas coast from Brownsville to Sabine. The Texas General Land...

  15. The software for the CERN LEP beam orbit measurement system

    International Nuclear Information System (INIS)

    Morpurgo, G.

    1992-01-01

    The Beam Orbit Measurement (BOM) system of LEP consists of 504 pickups, distributed all around the accelerator, that are capable of measuring the positions of the two beams. Their activity has to be synchronized, and the data produced by them have to be collected together, for example to form a 'closed orbit measurement' or a 'trajectory measurement'. On the user side, several clients can access simultaneously the results from this instrument. An automatic acquisition mode, and an 'on request' one, can run in parallel. This results in a very flexible and powerful system. The functionality of the BOM system is fully described, as well as the structure of the software processes which constitute the system, and their interconnections. Problems solved during the implementation are emphasized. (author)

  16. An Antenna Measurement System Based on Optical Feeding

    Directory of Open Access Journals (Sweden)

    Ryohei Hosono

    2013-01-01

    the advantage of the system is demonstrated by measuring an ultra-wideband (UWB antenna both by the optical and electrical feeding systems and comparing with a calculated result. Ripples in radiation pattern due to the electrical feeding are successfully suppressed by the optical feeding. For example, in a radiation measurement on the azimuth plane at 3 GHz, ripple amplitude of 1.0 dB that appeared in the electrical feeding is reduced to 0.3 dB. In addition, a circularly polarized (CP antenna is successfully measured by the proposed system to show that the system is available not only for amplitude but also phase measurements.

  17. Accurate volume measurement system for plutonium nitrate solution

    Energy Technology Data Exchange (ETDEWEB)

    Hosoma, Takashi; Maruishi, Yoshihiro (Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan). Tokai Works); Aritomi, Masanori; Kawa, Tunemichi

    1993-05-01

    An accurate volume measurement system for a large amount of plutonium nitrate solution stored in a reprocessing or a conversion plant has been developed at the Plutonium Conversion Development Facility (PCDF) in the Power Reactor and Nuclear Fuel Development Corp. (PNC) Tokai Works. A pair of differential digital quartz pressure transducers is utilized in the volume measurement system. To obtain high accuracy, it is important that the non-linearity of the transducer is minimized within the measurement range, the zero point is stabilized, and the damping property of the pneumatic line is designed to minimize pressure oscillation. The accuracy of the pressure measurement can always be within 2Pa with re-calibration once a year. In the PCDF, the overall uncertainty of the volume measurement has been evaluated to be within 0.2 %. This system has been successfully applied to the Japanese government's and IAEA's routine inspection since 1984. (author).

  18. Human factors research using the EPRI performance measurement system

    International Nuclear Information System (INIS)

    Kozinsky, E.J.

    1982-01-01

    A computer-based evaluation system has been developed for objectively measuring certain elements of an operator's performance on a power plant simulator. The Performance Measurement System (PMS) is designed to help the instructor in his total evaluation by providing measurements and documentation of certain essential elements of a trainee's performance. Some measurements of operator performance can be applied to Human Factors research on the operator - control room interface. The computerized system provides measurements of how the operator has responded to plant indicators and made switch manipulations. Magnetic tape data containing indications of all the control room gauges, annunciator lights, and switch and knob positions are collected, with time to one-second accuracy

  19. Attitude angular measurement system based on MEMS accelerometer

    Science.gov (United States)

    Luo, Lei

    2014-09-01

    For the purpose of monitoring the attitude of aircraft, an angular measurement system using a MEMS heat convection accelerometer is presented in this study. A double layers conditioning circuit that center around the single chip processor is designed and built. Professional display software with the RS232 standard is used to communicate between the sensor and the computer. Calibration experiments were carried out to characterize the measuring system with the range of - 90°to +90°. The curves keep good linearity with the practical angle. The maximum deviation occurs at the 90°where the value is 2.8°.The maximum error is 1.6% and the repeatability is measured to be 2.1%. Experiments proved that the developed measurement system is capable of measuring attitude angle.

  20. Measurement system analysis for one-sided tolerance

    Directory of Open Access Journals (Sweden)

    Szemik Kamil

    2017-01-01

    Full Text Available Measurement system analysis is carried out in order to determine if a capability to perform measurements in terms of product and process control is sufficient, indicating that the type I and the type II appraisal errors probability are acceptable. Statistical analyses for measurement system evaluation presented in the literature and the industrial manuals are not applicable for all complex and unusual applications. Therefore, the purpose of this study was to develop a robust statistical analysis method for measurement system variability analysis, in terms of product control scenario applied to one-sided tolerance. In the hereby presented study, the authors presented the theoretical principles of statistical techniques for measurement variations evaluation. Subsequently, the formula of gauge repeatability and reproducibility in terms of lower specification limit was proposed. The research hypothesis was tested using the statistical analysis.

  1. Simuluating quantum many-body systems subject to measurements

    DEFF Research Database (Denmark)

    Gammelmark, Søren

    is found. The technique is exemplified by numerical simulations of the antiferromagnetic Heisenberg spin-chain model subject to various instances of the measurement model. In particular, we focus on local measurements with small support and nonlocal measurements, which induce long-range correlations.......We demonstrate how to simulate both discrete and continuous stochastic evolutions of a quantum many-body system subject to measurements using matrix product states. A particular, but generally applicable, measurement model is analyzed and a simple representation in terms of matrix product operators...

  2. Simulating quantum many-body systems subject to measurements

    DEFF Research Database (Denmark)

    Gammelmark, Søren

    is found. The technique is exemplified by numerical simulations of the antiferromagnetic Heisenberg spin-chain model subject to various instances of the measurement model. In particular, we focus on local measurements with small support and nonlocal measurements, which induce long-range correlations.......We demonstrate how to simulate both discrete and continuous stochastic evolutions of a quantum many-body system subject to measurements using matrix product states. A particular, but generally applicable, measurement model is analyzed and a simple representation in terms of matrix product operators...

  3. Projective measurements in quantum and classical optical systems

    CSIR Research Space (South Africa)

    Roux, FS

    2014-09-01

    Full Text Available equally well to both classical and quantum optical systems. A projective measurement, in the context of quantum mechanics, is understood to be the process where a projection operator operates on some input state. Often this projection operator is composed...) Projective measurements in quantum and classical optical systems Filippus S. Roux* and Yingwen Zhang CSIR National Laser Centre, P.O. Box 395, Pretoria 0001, South Africa (Received 3 July 2014; published 22 September 2014) Experimental setups for the optical...

  4. The flow measurement plan for the primary system of SMART

    International Nuclear Information System (INIS)

    Lee, Jun; Seo, J. K.; Park, C. T.; Yoon, J. H.; Cho, B. H.; Lee, D. J.

    2001-08-01

    It is the common features of the integrated reactor that the main components of the primary system are installed within the reactor vessel, and so there are no any flow pipes connecting the reactor coolant pumps or steam generators. Due to no any flow pipes, it is impossible to measure the differential pressure at the primary system of the integrated reactor, and it also makes impossible measure the primary coolant flow rate. SMART is also a integrated reactor type, and have a problem as same as the above case. The objective of the study is to draw up the flow measurement plan for the primary system of SMART. In this study, firstly we reviewed the flow measurement methods at the primary system for the existing commercial nuclear power reactors. As a result of the review, we selected preliminarily the 3 methods which is a good possibility of application to SMART. The 3 methods are as follows. Flow measurement method by MCP rotation speed, flow measurement method by HBM, flow measurement method by pump motor power. For the above methods, we have evaluated whether they actually can be applied to SMART, and also have set up the concrete methodology. Finally we have made a selection of the above methods as the flow measurement plan for the primary system of SMART. Peculiarly, we did not found out a precedent which the direct pump motor power-flow rate curve is used as the flow measurement method in the existing commercial nuclear power reactors. Therefore, to use this method for SMART, it is needed to bear the follow-up measures in mind. The follow-up measures is included in this report

  5. Hierarchical, Three-Dimensional Measurement System for Crime Scene Scanning.

    Science.gov (United States)

    Marcin, Adamczyk; Maciej, Sieniło; Robert, Sitnik; Adam, Woźniak

    2017-07-01

    We present a new generation of three-dimensional (3D) measuring systems, developed for the process of crime scene documentation. This measuring system facilitates the preparation of more insightful, complete, and objective documentation for crime scenes. Our system reflects the actual requirements for hierarchical documentation, and it consists of three independent 3D scanners: a laser scanner for overall measurements, a situational structured light scanner for more minute measurements, and a detailed structured light scanner for the most detailed parts of tscene. Each scanner has its own spatial resolution, of 2.0, 0.3, and 0.05 mm, respectively. The results of interviews we have conducted with technicians indicate that our developed 3D measuring system has significant potential to become a useful tool for forensic technicians. To ensure the maximum compatibility of our measuring system with the standards that regulate the documentation process, we have also performed a metrological validation and designated the maximum permissible length measurement error E MPE for each structured light scanner. In this study, we present additional results regarding documentation processes conducted during crime scene inspections and a training session. © 2017 American Academy of Forensic Sciences.

  6. Automatic control system for measuring currents produced by ionization chambers

    International Nuclear Information System (INIS)

    Brancaccio, Franco

    2002-01-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for 18 F and 153 Sm were obtained, making possible to determine activities of these radionuclides. (author)

  7. Measurements of drag and flow over biofilm

    Science.gov (United States)

    Hartenberger, Joel; Gose, James W.; Perlin, Marc; Ceccio, Steven L.

    2017-11-01

    Microbial `slime' biofilms detrimentally affect the performance of every day systems from medical devices to large ocean-going vessels. In flow applications, the presence of biofilm typically results in a drag increase and may alter the turbulence in the adjacent boundary layer. Recent studies emphasize the severity of the drag penalty associated with soft biofouling and suggest potential mechanisms underlying the increase; yet, fundamental questions remain-such as the role played by compliance and the contribution of form drag to the overall resistance experienced by a fouled system. Experiments conducted on live biofilm and 3D printed rigid replicas in the Skin-Friction Flow Facility at the University of Michigan seek to examine these factors. The hydrodynamic performance of the biofilms grown on test panels was evaluated through pressure drop measurements as well as conventional and microscale PIV. High-resolution, 3D rigid replicas of select cases were generated via additive manufacturing using surface profiles obtained from a laser scanning system. Drag and flow measurements will be presented along with details of the growth process and the surface profile characterization method.

  8. Consensus of Multiagent Systems with Sampled Information and Noisy Measurements

    Directory of Open Access Journals (Sweden)

    Zhao-Jun Tang

    2013-01-01

    Full Text Available We consider consensus problems of first-order multiagent systems with sampled information and noisy measurements. A distributed stochastic approximation type algorithm is employed to attenuate the measurement noises. We provide conditions under which almost sure strong consensus is guaranteed for fixed and switching directed network topologies. Simulation results are provided to illustrate the theoretical results.

  9. Implementation and Rejection of Industrial Steam System Energy Efficiency Measures

    Energy Technology Data Exchange (ETDEWEB)

    Therkelesen, Peter [Environmental Energy Technologies Division Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States); McKane, Aimee [Environmental Energy Technologies Division Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)

    2013-05-01

    Steam systems consume approximately one third of energy applied at U.S. industrial facilities. To reduce energy consumption, steam system energy assessments have been conducted on a wide range of industry types over the course of five years through the Energy Savings Assessment (ESA) program administered by the U.S. Department of Energy (U.S. DOE). ESA energy assessments result in energy efficiency measure recommendations that are given potential energy and energy cost savings and potential implementation cost values. Saving and cost metrics that measure the impact recommended measures will have at facilities, described as percentages of facility baseline energy and energy cost, are developed from ESA data and used in analyses. Developed savings and cost metrics are examined along with implementation and rejection rates of recommended steam system energy efficiency measures. Based on analyses, implementation of steam system energy efficiency measures is driven primarily by cost metrics: payback period and measure implementation cost as a percentage of facility baseline energy cost (implementation cost percentage). Stated reasons for rejecting recommended measures are primarily based upon economic concerns. Additionally, implementation rates of measures are not only functions of savings and cost metrics, but time as well.

  10. Measurement System for Playout Delay of TV Signals

    NARCIS (Netherlands)

    Kooij, W.J.; Stokking, H.M.; Brandenburg, R. van; Boer, P.T. de

    2014-01-01

    TV signals are carried towards end-users using different (broadcast) technologies and by different providers. This is causing differences in the playout timing of the TV signal at different locations and devices. Authors have developed a measurement system for measuring the relative playout delay of

  11. Logarithmic derivative method and system for capacitance measurement.

    Science.gov (United States)

    Wu, Yichun; Wang, Lingzhi; Cai, Yuanfeng; Wu, Cunqiao

    2015-08-01

    A novel method based on logarithmic derivative is introduced to analyze multi-lifetime decay. As the discharge voltage signal of a RC circuit is a special kind of multi-lifetime exponential decay, the logarithmic derivative method can be used to measure single capacitance and multiple capacitances. With the logarithmic derivative method, a log(t) curve strongly peaked at precisely log(τ) is obtained, where the lifetime τ equals to RC. In a measurement system, if the resistance R is known, then the capacitance under test can be calculated. A logarithmic derivative curve fitting method is also presented, which has better anti-noise capability than the method that simply finds the maximum data on the peak. The curve fitting method can also be used for multiple capacitors measurement. To measure small capacitances, a large enough time window of the measuring instrument is required. Based on a field programmable gate array and a high speed analog-to-digital converter, a measurement system is developed. This system can provide the 16-bit resolution with sampling rate up to 250 MHz, which has a large enough time window for measuring lifetime shorter than 10(-8) s. To reduce the amount of data needed to be stored and the noise due to the derivative treatment of transient data, the interpolation and noise-filter algorithms are employed. Experiments indicate that the logarithmic derivative method and system are suitable for the measurement of capacitances discharge and other exponential decay processes.

  12. 24 CFR 84.15 - Metric system of measurement.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Metric system of measurement. 84.15 Section 84.15 Housing and Urban Development Office of the Secretary, Department of Housing and Urban... measurement. The Metric Conversion Act, as amended by the Omnibus Trade and Competitiveness Act (15 U.S.C. 205...

  13. A laboratory goniometer system for measuring reflectance and emittance anisotropy

    NARCIS (Netherlands)

    Roosjen, P.P.J.; Clevers, J.G.P.W.; Bartholomeus, H.; Schaepman, M.E.; Schaepman-Strub, G.; Jalink, H.; Schoor, van der R.; Jong, de A.

    2012-01-01

    In this paper, a laboratory goniometer system for performing multi-angular measurements under controlled illumination conditions is described. A commercially available robotic arm enables the acquisition of a large number of measurements over the full hemisphere within a short time span making it

  14. Procurement performance measurement system in the health care industry.

    Science.gov (United States)

    Kumar, Arun; Ozdamar, Linet; Ng, Chai Peng

    2005-01-01

    The rising operating cost of providing healthcare is of concern to health care providers. As such, measurement of procurement performance will enable competitive advantage and provide a framework for continuous improvement. The objective of this paper is to develop a procurement performance measurement system. The paper reviews the existing literature in procurement performance measurement to identify the key areas of purchasing performance. By studying the three components in the supply chain collectively with the resources, procedures and output, a model is been developed. Additionally, a balanced scorecard is proposed by establishing a set of generic measures and six perspectives. A case study conducted at the Singapore Hospital applies the conceptual model to describe the purchasing department and the activities within and outside the department. The results indicate that the material management department has already made a good start in measuring the procurement process through the implementation of the balanced scorecard. There are many data that are collected but not properly collated and utilized. Areas lacking measurement include cycle time of delivery, order processing time, effectiveness, efficiency and reliability. Though a lot of hard work was involved, the advantages of establishing a measurement system outweigh the costs and efforts involved in its implementation. Results of balanced scorecard measurements provide decision-makers with critical information on efficiency and effectiveness of the purchasing department's work. The measurement model developed could be used for any hospital procurement system.

  15. A robotic vision system to measure tree traits

    Science.gov (United States)

    The autonomous measurement of tree traits, such as branching structure, branch diameters, branch lengths, and branch angles, is required for tasks such as robotic pruning of trees as well as structural phenotyping. We propose a robotic vision system called the Robotic System for Tree Shape Estimati...

  16. Entropic uncertainty measures for large dimensional hydrogenic systems

    NARCIS (Netherlands)

    D. Puertas-Centeno; N.M. Temme (Nico); I.V. Toranzo; J.S. Dehesa

    2017-01-01

    textabstractThe entropic moments of the probability density of a quantum system in position and momentum spaces describe not only some fundamental and/or experimentally accessible quantities of the system but also the entropic uncertainty measures of Rényi type, which allow one to find the most

  17. Improved measurement system for the whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1983-01-01

    A static four-detector system has been established as a whole body radioactivity measurement system. A technique is being developed to position the detectors in such a manner as to minimise longitudinal distribution effects within a subject. This technique, which represents the human body as a simple geometric model, requires the determination of efficiency at any point within this model

  18. Estimating angle-dependent systematic error and measurement uncertainty for a conoscopic holography measurement system

    Science.gov (United States)

    Paviotti, Anna; Carmignato, Simone; Voltan, Alessandro; Laurenti, Nicola; Cortelazzo, Guido M.

    2009-01-01

    The aim of this study is to assess angle-dependent systematic errors and measurement uncertainties for a conoscopic holography laser sensor mounted on a Coordinate Measuring Machine (CMM). The main contribution of our work is the definition of a methodology for the derivation of point-sensitive systematic and random errors, which must be determined in order to evaluate the accuracy of the measuring system. An ad hoc three dimensional artefact has been built for the task. The experimental test has been designed so as to isolate the effects of angular variations from those of other influence quantities that might affect the measurement result. We have found the best measurand to assess angle-dependent errors, and found some preliminary results on the expression of the systematic error and measurement uncertainty as a function of the zenith angle for the chosen measurement system and sample material.

  19. [Principles and experimental analysis of a measuring system for measuring spacesuit joint's damping parameters].

    Science.gov (United States)

    Wang, Hao; Jin, Ming-he; Liu, Hong; Gao, Xiao-hui; Li, Tan-qiu; Zhao, Yong-jun

    2003-10-01

    To measure the damping parameters of the spacesuit joint. The principles of the passive robot system for measuring spacesuit joint's damping parameters were presented. Basing on its special mechanical structure, a 3 DOF model of the flexible IVA (intra-vehicular activity) spacesuit's sleeve was built. The optimal approximation of inverse calculation based on 6 dimension space interval was described. The damping parameters of an actual IVA spacesuit's sleeve were measured on the actual testbed. Also, the potential application of the measuring system was discussed. The model of spacesuit sleeve and the forward/inverse kinematics were proved by experimental measurements and real time 3D simulation. The principles and the proposed method of the measurement were testified.

  20. A new system for the measurement of the space radiation

    International Nuclear Information System (INIS)

    Pazmandi, T.; Apathy, I.; Deme, S.; Beaujean, R.

    2000-01-01

    Radiation from space mainly consists of charged heavy particles (protons and heavier particles). Due to this fact, the effective dose significantly differs from the physical dose. Current measuring equipment is not fully suitable to measure both of the quantities simultaneously. A combined device for measurement of the mentioned values consists of an on-board thermoluminescence dosimeter reader and a three-axis silicon detector linear energy transfer spectrometer. This paper deals with the main characteristic of the new system. This system can be, applied for dosimetry of air crew as well. (authors)

  1. A new system for measurement of the space radiation

    International Nuclear Information System (INIS)

    Pazmandi, T.; Apathy, I.; Deme, S.; Beaujean, R.

    2001-01-01

    The space radiation mainly consists of heavy charged particles (protons and heavier particles). Due to this fact its effective dose significantly differs from the physical dose. The recently used measuring equipment is not fully suitable to measure both quantities simultaneously. The combined device for measurement of mentioned values consists of an on board thermoluminescent dosimeter reader and a three axis silicon telescope as a linear energy transfer spectrometer. The paper deals with the main characteristics of the new system. This system can be applied for dosimetry of air-crew as well. (authors)

  2. Experiences with phantom measurements in different mammographic systems

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Lell, M.; Kuchar, I.; Bautz, W.

    2002-01-01

    Purpose: Determination of image quality between conventional film screen system, digital phosphor storage plate mammography (high resolution) and digital mammography. Materials and Methods: Mammograms of the Wisconsin Mammographic Random Phantom, Model 152 A (Radiation Measurements Inc., Wisconsin) were acquired using a conventional film-screen system, a digital storage phosphor plate system and a digital system. Results: Of 225 possible details, 191/a 38.2, 193/a 38.6, and 202/a 40.4 details were detected with conventional film-screen system, digital phosphor storage plate mammography and digital mammography, respectively. There was no significant difference (p [de

  3. Development of a system to measure local measurement conditions around textile electrodes.

    Science.gov (United States)

    Kim, Saim; Oliveira, Joana; Roethlingshoefer, Lisa; Leonhard, Steffen

    2010-01-01

    The three main influence factors on the interface between textile electrode an skin are: temperature, contact pressure and relative humidity. This paper presents first results of a prototype, which measures these local measurement conditions around textile electrodes. The wearable prototype is a data acquisition system based on a microcontroller with a flexible sensor sleeve. Validation measurements included variation of ambient temperature, contact pressures and sleeve material. Results show a good correlation with data found in literature.

  4. Noise Susceptibility Measurements of Front-End Electronics Systems

    CERN Document Server

    Allongue, B; Blanchot, G; Faccio, F; Fuentes, C; Michelis, S; Orlandi, S; Toro, A

    2008-01-01

    The conducted and radiated noise that is emitted by a power supply constrains the noise performance of the frontend electronics system that it powers. The characterization of the noise susceptibility of the front-end electronics allows setting proper requirements for the back-end power supply in order to achieve the expected system performance. A method to measure the common mode current susceptibility using current probes is presented. The compatibility between power supplies and various front-end systems is explored.

  5. New Vehicle Speed Measurement System with Image Processing

    OpenAIRE

    Goda, Yuji; Chen, Shenjing; Zhang, Lifeng

    2014-01-01

    This research proposes a new vehicle speed measuring system based on image processing technique. Generally, in order to detect the vehicle from image taken in dark circumstance, expensive high-performance camera is needed. However, this system needs only a cheap general camera, like digital camera or the camera mounted on smartphones. Thereby, this system uses as speed gun. By controlling the shutter speed of camera, a bright line which comes from the headlamp of a moving vehicle is appeared ...

  6. Diagnostic and Measuring Systems of the Power Transformers

    Directory of Open Access Journals (Sweden)

    Jan Michalik

    2003-01-01

    Full Text Available In the article the diagnostic and measuring systems dedicated for complex output tests of power transformers aswell as their diagnostic is dcscribcd. The aim of research in this area was to elaborate the problem of so-called open loop measuring system controlled by PC. The attribute "open" means the possibility to adapt the system for different electric equipment, different measurands and an zdaptation of the way of monitoring, evaluation and distribution of output information according to specific requirements the controlled transformer.

  7. Armando System Measurements at R-306 FY 2003 Report

    CERN Document Server

    Lutz, S S

    2003-01-01

    This report details some of the measurements made by Bechtel Nevada (BN) to characterize the Armando radiographic detection system and marks the completion of the R-306 Armando System Characterization milestone. The measurements, made in July 2003, utilized the Cygnus pulse power machine, which was assembled at the Los Alamos National Laboratory (LANL) Firing Site R-306. This report describes the test configuration used and the findings concerning the following Armando radiographic detection system issues for source spot size, mirror vs. pellicle performance, scintillator configuration evaluation, resolution and reproducibility, off-axis scatter contribution, and source spectra reproducibility.

  8. Surface moisture measurement system hardware acceptance test procedure

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1996-01-01

    The purpose of this acceptance test procedure is to verify that the mechanical and electrical features of the Surface Moisture Measurement System are operating as designed and that the unit is ready for field service. This procedure will be used in conjunction with a software acceptance test procedure, which addresses testing of software and electrical features not addressed in this document. Hardware testing will be performed at the 306E Facility in the 300 Area and the Fuels and Materials Examination Facility in the 400 Area. These systems were developed primarily in support of Tank Waste Remediation System (TWRS) Safety Programs for moisture measurement in organic and ferrocyanide watch list tanks

  9. System for measuring of proton polarization in polarized target

    International Nuclear Information System (INIS)

    Derkach, A.Ya.; Lukhanin, A.A.; Karnaukhov, I.M.; Kuz'menko, V.S.; Telegin, Yu.N.; Trotsenko, V.I.; Chechetenko, V.F.

    1981-01-01

    Measurement system of proton polarization in the target, which uses the method of nuclear magnetic resonance is described. To record the signal of NMR-absorption a parallel Q-meter of voltage with analogous subtraction of resonance characteristics of measurement circuit is used. To obtain gradual sensitivity of the system to polarization state in the whole volume of the target the measurement coils is made of tape conductor. The analysis and mathematical modelling of Q-meter are carried out. Corrections for nonlinearity and dispersion are calculated. Key diagrams of the main electron blocks of Q-meter are presented. The system described operates on line with the M6000 computer. Total error of measurement of polarization value of free protons in the target does not exceed 6% [ru

  10. Escape rate scaling in infinite measure preserving systems

    International Nuclear Information System (INIS)

    Munday, Sara; Knight, Georgie

    2016-01-01

    We investigate the scaling of the escape rate from piecewise linear dynamical systems displaying intermittency due to the presence of an indifferent fixed point. Strong intermittent behaviour in the dynamics can result in the system preserving an infinite measure. We define a neighbourhood of the indifferent fixed point to be a hole through which points escape and investigate the scaling of the rate of this escape as the length of the hole decreases, both in the finite measure preserving case and infinite measure preserving case. In the infinite measure preserving systems we observe logarithmic corrections to and polynomial scaling of the escape rate with hole length. Finally we conjecture a relationship between the wandering rate and the observed scaling of the escape rate. (paper)

  11. The AD and ELENA orbit, trajectory and intensity measurement systems

    Science.gov (United States)

    Marco-Hernández, R.; Alves, D.; Angoletta, M. E.; Marqversen, O.; Molendijk, J.; Oponowicz, E.; Ruffieux, R.; Sánchez-Quesada, J.; SØby, L.

    2017-07-01

    This paper describes the new Antiproton Decelerator (AD) orbit measurement system and the Extra Low ENergy Antiproton ring (ELENA) orbit, trajectory and intensity measurement system. The AD machine at European Organization for Nuclear Research (CERN) is presently being used to decelerate antiprotons from 3.57 GeV/c to 100 MeV/c for matter vs anti-matter comparative studies. The ELENA machine, presently under commissioning, has been designed to provide an extra deceleration stage down to 13.7 MeV/c. The AD orbit system is based on 32 horizontal and 27 vertical electrostatic Beam Position Monitor (BPM) fitted with existing low noise front-end amplifiers while the ELENA system consists of 24 \\gls{BPM}s equipped with new low-noise head amplifiers. In both systems the front-end amplifiers generate a difference (delta) and a sum (sigma) signal which are sent to the digital acquisition system, placed tens of meters away from the AD or ELENA rings, where they are digitized and further processed. The beam position is calculated by dividing the difference signal by the sum signal either using directly the raw digitized data for measuring the turn-by-turn trajectory in the ELENA system or after down-mixing the signals to baseband for the orbit measurement in both machines. The digitized sigma signal will be used in the ELENA system to calculate the bunched beam intensity and the Schottky parameters with coasting beam after passing through different signal processing chain. The digital acquisition arrangement for both systems is based on the same hardware, also used in the ELENA Low Level Radio Frequency (LLRF) system, which follows the VME Switched Serial (VXS) enhancement of the Versa Module Eurocard 64x extension (VME64x) standard and includes VITA 57 standard Field Programmable Gate Array Mezzanine Card (FMC). The digital acquisition Field Programmable Gate Array (FPGA) and Digital Signal Processor (DSP) firmware shares many common functionalities with the LLRF system but

  12. Development of an integrated control and measurement system

    International Nuclear Information System (INIS)

    Manges, W.W.

    1984-03-01

    This thesis presents a tutorial on the issues involved in the development of a minicomputer-based, distributed intelligence data acquisition and process control system to support complex experimental facilities. The particular system discussed in this thesis is under development for the Atomic Vapor Laser Isotope Separation (AVLIS) Program at the Oak Ridge Gaseous Diffusion Plant (ORGDP). In the AVLIS program, we were careful to integrate the computer sections of the implementation into the instrumentation system rather than adding them as an appendage. We then addressed the reliability and availability of the system as a separate concern. Thus, our concept of an integrated control and measurement (ICAM) system forms the basis for this thesis. This thesis details the logic and philosophy that went into the development of this system and explains why the commercially available turn-key systems generally are not suitable. Also, the issues involved in the specification of the components for such an integrated system are emphasized

  13. Remote measurements of radioactivity distribution with BROKK robotic system - 16147

    International Nuclear Information System (INIS)

    Ivanov, Oleg; Danilovich, Alexey; Stepanov, Vyacheslav; Smirnov, Sergey; Potapov, Victor

    2009-01-01

    Robotic system for the remote measurement of radioactivity in the reactor areas was developed. The BROKK robotic system replaces hand-held radiation measuring tools. The system consists of a collimated gamma detector, a standard gamma detector, color CCD video camera and searchlights, all mounted on a robotic platform (BROKK). The signals from the detectors are coupled with the video signals and are transferred to an operator's console via a radio channel or a cable. Operator works at a safe position. The video image of the object with imposed exposure dose rate from the detectors generates an image on the monitor screen, and the images are recorded for subsequent analysis. Preliminary work has started for the decommissioning of a research reactor at the RRC 'Kurchatov Institute'. Results of the remote radioactivity measurements with new system during radiation inspection waste storage of this reactor are presented and discussed. (authors)

  14. Arrester Resistive Current Measuring System Based on Heterogeneous Network

    Science.gov (United States)

    Zhang, Yun Hua; Li, Zai Lin; Yuan, Feng; Hou Pan, Feng; Guo, Zhan Nan; Han, Yue

    2018-03-01

    Metal Oxide Arrester (MOA) suffers from aging and poor insulation due to long-term impulse voltage and environmental impact, and the value and variation tendency of resistive current can reflect the health conditions of MOA. The common wired MOA detection need to use long cables, which is complicated to operate, and that wireless measurement methods are facing the problems of poor data synchronization and instability. Therefore a novel synchronous measurement system of arrester current resistive based on heterogeneous network is proposed, which simplifies the calculation process and improves synchronization, accuracy and stability and of the measuring system. This system combines LoRa wireless network, high speed wireless personal area network and the process layer communication, and realizes the detection of arrester working condition. Field test data shows that the system has the characteristics of high accuracy, strong anti-interference ability and good synchronization, which plays an important role in ensuring the stable operation of the power grid.

  15. Development of measurement system for gauge block interferometer

    Science.gov (United States)

    Chomkokard, S.; Jinuntuya, N.; Wongkokua, W.

    2017-09-01

    We developed a measurement system for collecting and analyzing the fringe pattern images from a gauge block interferometer. The system was based on Raspberry Pi which is an open source system with python programming and opencv image manipulation library. The images were recorded by the Raspberry Pi camera with five-megapixel capacity. The noise of images was suppressed for the best result in analyses. The low noise images were processed to find the edge of fringe patterns using the contour technique for the phase shift analyses. We tested our system with the phase shift patterns between a gauge block and a reference plate. The phase shift patterns were measured by a Twyman-Green type of interferometer using the He-Ne laser with the temperature controlled at 20.0 °C. The results of the measurement will be presented and discussed.

  16. Drone based measurement system for radiofrequency exposure assessment.

    Science.gov (United States)

    Joseph, Wout; Aerts, Sam; Vandenbossche, Matthias; Thielens, Arno; Martens, Luc

    2016-03-10

    For the first time, a method to assess radiofrequency (RF) electromagnetic field (EMF) exposure of the general public in real environments with a true free-space antenna system is presented. Using lightweight electronics and multiple antennas placed on a drone, it is possible to perform exposure measurements. This technique will enable researchers to measure three-dimensional RF-EMF exposure patterns accurately in the future and at locations currently difficult to access. A measurement procedure and appropriate measurement settings have been developed. As an application, outdoor measurements are performed as a function of height up to 60 m for Global System for Mobile Communications (GSM) 900 MHz base station exposure. Bioelectromagnetics. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Bohmian mechanics, open quantum systems and continuous measurements

    CERN Document Server

    Nassar, Antonio B

    2017-01-01

    This book shows how Bohmian mechanics overcomes the need for a measurement postulate involving wave function collapse. The measuring process plays a very important role in quantum mechanics. It has been widely analyzed within the Copenhagen approach through the Born and von Neumann postulates, with later extension due to Lüders. In contrast, much less effort has been invested in the measurement theory within the Bohmian mechanics framework. The continuous measurement (sharp and fuzzy, or strong and weak) problem is considered here in this framework. The authors begin by generalizing the so-called Mensky approach, which is based on restricted path integral through quantum corridors. The measuring system is then considered to be an open quantum system following a stochastic Schrödinger equation. Quantum stochastic trajectories (in the Bohmian sense) and their role in basic quantum processes are discussed in detail. The decoherence process is thereby described in terms of classical trajectories issuing from th...

  18. Development of distance measurement system using Ar laser under water

    International Nuclear Information System (INIS)

    Murakawa, Shinichi; Shibaike, Kunio; Shimizu, Sumiya; Yoshimura, Koji; Aoyama, Tomio

    1996-01-01

    For positioning measurement of an underwater vehicle robot in a reactor pressure vessel for ultrasonic inspection of the vessel, we developed distance measurement system using pan/tilt mechanisms to control directions of an argon gas laser and outgoing/incoming lights. This can automatically measure three-dimensional position and follow of the underwater vehicle robot up to 0.5 ppm water turbidity, this is the first of its kind in the world. This system can measure up to maximum length measuring distance of 8.5 m underwater, within a ±3.6 mm error. We adopted the power 75 mW output for argon gas laser modulated at 80 MHz, and a detector with resolution of 0.004 degree for the pan/tilt mechanisms. (author)

  19. Low Power Shoe Integrated Intelligent Wireless Gait Measurement System

    Science.gov (United States)

    Wahab, Y.; Mazalan, M.; Bakar, N. A.; Anuar, A. F.; Zainol, M. Z.; Hamzah, F.

    2014-04-01

    Gait analysis measurement is a method to assess and identify gait events and the measurements of dynamic, motion and pressure parameters involving the lowest part of the body. This significant analysis is widely used in sports, rehabilitation as well as other health diagnostic towards improving the quality of life. This paper presents a new system empowered by Inertia Measurement Unit (IMU), ultrasonic sensors, piezoceramic sensors array, XBee wireless modules and Arduino processing unit. This research focuses on the design and development of a low power ultra-portable shoe integrated wireless intelligent gait measurement using MEMS and recent microelectronic devices for foot clearance, orientation, error correction, gait events and pressure measurement system. It is developed to be cheap, low power, wireless, real time and suitable for real life in-door and out-door environment.

  20. A complex network-based importance measure for mechatronics systems

    Science.gov (United States)

    Wang, Yanhui; Bi, Lifeng; Lin, Shuai; Li, Man; Shi, Hao

    2017-01-01

    In view of the negative impact of functional dependency, this paper attempts to provide an alternative importance measure called Improved-PageRank (IPR) for measuring the importance of components in mechatronics systems. IPR is a meaningful extension of the centrality measures in complex network, which considers usage reliability of components and functional dependency between components to increase importance measures usefulness. Our work makes two important contributions. First, this paper integrates the literature of mechatronic architecture and complex networks theory to define component network. Second, based on the notion of component network, a meaningful IPR is brought into the identifying of important components. In addition, the IPR component importance measures, and an algorithm to perform stochastic ordering of components due to the time-varying nature of usage reliability of components and functional dependency between components, are illustrated with a component network of bogie system that consists of 27 components.

  1. Limitations and corrections in measuring dynamic characteristics of structural systems

    International Nuclear Information System (INIS)

    Walter, P.L.

    1978-10-01

    The work deals with limitations encountered in measuring the dynamic characteristics of structural systems. Structural loading and response are measured by transducers possessing multiple resonant frequencies in their transfer function. In transient environments, the resultant signals from these transducers are shown to be analytically unpredictable in amplitude level and frequency content. Data recorded during nuclear effects simulation testing on structures are analyzed. Results of analysis can be generalized to any structure which encounters dynamic loading. Methods to improve the recorded data are described which can be implemented on a frequency selective basis during the measurement process. These improvements minimize data distortion attributable to the transfer characteristics of the measuring transducers

  2. A lidar system for measuring atmospheric pressure and temperature profiles

    Science.gov (United States)

    Schwemmer, Geary K.; Dombrowski, Mark; Korb, C. Laurence; Milrod, Jeffry; Walden, Harvey

    1987-01-01

    The design and operation of a differential absorption lidar system capable of remotely measuring the vertical structure of tropospheric pressure and temperature are described. The measurements are based on the absorption by atmospheric oxygen of the spectrally narrowband output of two pulsed alexandrite lasers. Detailed laser output spectral characteristics, which are critical to successful lidar measurements, are presented. Spectral linewidths of 0.026 and 0.018 per cm for the lasers were measured with over 99.99 percent of the energy contained in three longitudinal modes.

  3. The correction of vibration in frequency scanning interferometry based absolute distance measurement system for dynamic measurements

    Science.gov (United States)

    Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu

    2015-10-01

    Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.

  4. Three-dimensional measurement system for crime scene documentation

    Science.gov (United States)

    Adamczyk, Marcin; Hołowko, Elwira; Lech, Krzysztof; Michoński, Jakub; MÄ czkowski, Grzegorz; Bolewicki, Paweł; Januszkiewicz, Kamil; Sitnik, Robert

    2017-10-01

    Three dimensional measurements (such as photogrammetry, Time of Flight, Structure from Motion or Structured Light techniques) are becoming a standard in the crime scene documentation process. The usage of 3D measurement techniques provide an opportunity to prepare more insightful investigation and helps to show every trace in the context of the entire crime scene. In this paper we would like to present a hierarchical, three-dimensional measurement system that is designed for crime scenes documentation process. Our system reflects the actual standards in crime scene documentation process - it is designed to perform measurement in two stages. First stage of documentation, the most general, is prepared with a scanner with relatively low spatial resolution but also big measuring volume - it is used for the whole scene documentation. Second stage is much more detailed: high resolution but smaller size of measuring volume for areas that required more detailed approach. The documentation process is supervised by a specialised application CrimeView3D, that is a software platform for measurements management (connecting with scanners and carrying out measurements, automatic or semi-automatic data registration in the real time) and data visualisation (3D visualisation of documented scenes). It also provides a series of useful tools for forensic technicians: virtual measuring tape, searching for sources of blood spatter, virtual walk on the crime scene and many others. In this paper we present our measuring system and the developed software. We also provide an outcome from research on metrological validation of scanners that was performed according to VDI/VDE standard. We present a CrimeView3D - a software-platform that was developed to manage the crime scene documentation process. We also present an outcome from measurement sessions that were conducted on real crime scenes with cooperation with Technicians from Central Forensic Laboratory of Police.

  5. Temperature and voltage measurement in quantum systems far from equilibrium

    Science.gov (United States)

    Shastry, Abhay; Stafford, Charles A.

    2016-10-01

    We show that a local measurement of temperature and voltage for a quantum system in steady state, arbitrarily far from equilibrium, with arbitrary interactions within the system, is unique when it exists. This is interpreted as a consequence of the second law of thermodynamics. We further derive a necessary and sufficient condition for the existence of a solution. In this regard, we find that a positive temperature solution exists whenever there is no net population inversion. However, when there is a net population inversion, we may characterize the system with a unique negative temperature. Voltage and temperature measurements are treated on an equal footing: They are simultaneously measured in a noninvasive manner, via a weakly coupled thermoelectric probe, defined by requiring vanishing charge and heat dissipation into the probe. Our results strongly suggest that a local temperature measurement without a simultaneous local voltage measurement, or vice versa, is a misleading characterization of the state of a nonequilibrium quantum electron system. These results provide a firm mathematical foundation for voltage and temperature measurements far from equilibrium.

  6. A System for Acoustic Field Measurement Employing Cartesian Robot

    Directory of Open Access Journals (Sweden)

    Szczodrak Maciej

    2016-09-01

    Full Text Available A system setup for measurements of acoustic field, together with the results of 3D visualisations of acoustic energy flow are presented in the paper. Spatial sampling of the field is performed by a Cartesian robot. Automatization of the measurement process is achieved with the use of a specialized control system. The method is based on measuring the sound pressure (scalar and particle velocity(vector quantities. The aim of the system is to collect data with a high precision and repeatability. The system is employed for measurements of acoustic energy flow in the proximity of an artificial head in an anechoic chamber. In the measurement setup an algorithm for generation of the probe movement path is included. The algorithm finds the optimum path of the robot movement, taking into account a given 3D object shape present in the measurement space. The results are presented for two cases, first without any obstacle and the other - with an artificial head in the sound field.

  7. An MEG compatible system for measuring skin conductance responses.

    Science.gov (United States)

    Styliadis, Charalampos; Papadelis, Christos; Konstantinidis, Evdokimos; Ioannides, Andreas A; Bamidis, Panagiotis

    2013-01-15

    We present the design of a low-cost system for recording galvanic skin conductance responses (SCRs) from humans in a magnetically shielded room (MSR) simultaneously to magnetoencephalography (MEG). Such a system was so far not available to the MEG community. Its availability is of utmost importance for neuroscience, since it will allow the concurrent assessment of the autonomic and central nervous system activity. The overall system design optimizes high signal to noise ratio (SNR) of SCRs and achieves minimal distortion of the MEG signal. Its development was based on a fiber-optic transformer, with voltage to optical transduction inside the MSR and demodulation outside the MSR. The system was calibrated and tested inside the MEG environment by using a 151-channel CTF whole head system (VSM MedTech Ltd.). MEG measurements were recorded simultaneously to SCRs from five healthy participants to test whether the developed system does not generate artifacts in the MEG data. Two measurements were performed for each participant; one without the system in the MSR, and one with the system in the MSR, connected to the participant and in operation. The data were analyzed using the time and frequency domains in separate statistical analysis. No significant differences were observed between the two sessions for any statistic index. Our results show that the system allows high quality simultaneous recordings of SCRs and MEG signals in the MSR, and can therefore be used as routine addendum to neuroscience experiments. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Dose measurements in space by the Hungarian Pille TLD system

    Energy Technology Data Exchange (ETDEWEB)

    Apathy, I.; Deme, S. E-mail: deme@sunserv.kfki.hu; Feher, I.; Akatov, Y.A.; Reitz, G.; Arkhanguelski, V.V

    2002-10-01

    Exposure of crew, equipment, and experiments to the ambient space radiation environment in low Earth orbit poses one of the most significant problems to long-term space habitation. Accurate dose measurement has become increasingly important during the assembly (extravehicular activity (EVA)) and operation of space stations such as on Space Station Mir. Passive integrating detector systems such as thermoluminescent dosemeters (TLDs) are commonly used for dosimetry mapping and personal dosimetry on space vehicles. The well-known advantages of passive detector systems are their independence of power supply, small dimensions, high sensitivity, good stability, wide measuring range, resistance to environmental effects, and relatively low cost. Nevertheless, they have the general disadvantage that for evaluation purposes they need a laboratory or large--in mass and power consumption--terrestrial equipment, and consequently they cannot provide time-resolved dose data during long-term space flights. KFKI Atomic Energy Research Institute (KFKI AEKI) has developed and manufactured a series of thermoluminescent dosemeter systems for measuring cosmic radiation doses in the 10 {mu}Gy to 10 Gy range, consisting of a set of bulb dosemeters and a compact, self-contained, TLD reader suitable for on-board evaluation of the dosemeters. By means of such a system, highly accurate measurements were carried out on board the Salyut-6, -7 and Mir Space Stations as well as on the Space Shuttle. A detailed description of the system is given and the comprehensive results of these measurements are summarised.

  9. Dose measurements in space by the Hungarian Pille TLD system

    International Nuclear Information System (INIS)

    Apathy, I.; Deme, S.; Feher, I.; Akatov, Y.A.; Reitz, G.; Arkhanguelski, V.V.

    2002-01-01

    Exposure of crew, equipment, and experiments to the ambient space radiation environment in low Earth orbit poses one of the most significant problems to long-term space habitation. Accurate dose measurement has become increasingly important during the assembly (extravehicular activity (EVA)) and operation of space stations such as on Space Station Mir. Passive integrating detector systems such as thermoluminescent dosemeters (TLDs) are commonly used for dosimetry mapping and personal dosimetry on space vehicles. The well-known advantages of passive detector systems are their independence of power supply, small dimensions, high sensitivity, good stability, wide measuring range, resistance to environmental effects, and relatively low cost. Nevertheless, they have the general disadvantage that for evaluation purposes they need a laboratory or large--in mass and power consumption--terrestrial equipment, and consequently they cannot provide time-resolved dose data during long-term space flights. KFKI Atomic Energy Research Institute (KFKI AEKI) has developed and manufactured a series of thermoluminescent dosemeter systems for measuring cosmic radiation doses in the 10 μGy to 10 Gy range, consisting of a set of bulb dosemeters and a compact, self-contained, TLD reader suitable for on-board evaluation of the dosemeters. By means of such a system, highly accurate measurements were carried out on board the Salyut-6, -7 and Mir Space Stations as well as on the Space Shuttle. A detailed description of the system is given and the comprehensive results of these measurements are summarised

  10. Development of a roundness measuring system for microspheres

    International Nuclear Information System (INIS)

    Fan, Kuang-Chao; Wang, Na; Wang, Zhi-Wei; Zhang, Hui

    2014-01-01

    In the field of micro/nano technology, microspheres are often used as the tip-ball of a measuring stylus, such as in micro/nano coordinate measuring machines (CMMs). Conventional tactile probes adopt ruby or steel balls with diameters in the range of several millimeters to 0.3 mm. For a micro-CMM, the required probing ball is as small as possible in order to be inserted into a small groove for side wall measurement. The exact diameter of the tip-ball has to be calibrated for radius compensation and its roundness error has to be qualified. A roundness measuring system for microspheres is developed in this study. Two small Michelson interferometers are designed for direct measurement of microsphere diameter from both sides, being a two-point method. By rotating the measured sphere and reading the displacement shifts of the two interferometers, the run-out of the sphere can be eliminated. The resolution of the developed system can reach 1 nm and the accuracy can reach 10 nm. Two microspheres are tested with good repeatability. This system can also be used for macrosphere measurement. (paper)

  11. Development of a roundness measuring system for microspheres

    Science.gov (United States)

    Fan, Kuang-Chao; Wang, Na; Wang, Zhi-Wei; Zhang, Hui

    2014-06-01

    In the field of micro/nano technology, microspheres are often used as the tip-ball of a measuring stylus, such as in micro/nano coordinate measuring machines (CMMs). Conventional tactile probes adopt ruby or steel balls with diameters in the range of several millimeters to 0.3 mm. For a micro-CMM, the required probing ball is as small as possible in order to be inserted into a small groove for side wall measurement. The exact diameter of the tip-ball has to be calibrated for radius compensation and its roundness error has to be qualified. A roundness measuring system for microspheres is developed in this study. Two small Michelson interferometers are designed for direct measurement of microsphere diameter from both sides, being a two-point method. By rotating the measured sphere and reading the displacement shifts of the two interferometers, the run-out of the sphere can be eliminated. The resolution of the developed system can reach 1 nm and the accuracy can reach 10 nm. Two microspheres are tested with good repeatability. This system can also be used for macrosphere measurement.

  12. Mammographic density measurements are not affected by mammography system.

    Science.gov (United States)

    Damases, Christine N; Brennan, Patrick C; McEntee, Mark F

    2015-01-01

    Mammographic density (MD) is a significant risk factor for breast cancer and has been shown to reduce the sensitivity of mammography screening. Knowledge of a woman's density can be used to predict her risk of developing breast cancer and personalize her imaging pathway. However, measurement of breast density has proven to be troublesome with wide variations in density recorded using radiologists' visual Breast Imaging Reporting and Data System (BIRADS). Several automated methods for assessing breast density have been proposed, each with their own source of measurement error. The use of differing mammographic imaging systems further complicates MD measurement, especially for the same women imaged over time. The purpose of this study was to investigate whether having a mammogram on differing manufacturer's equipment affects a woman's MD measurement. Raw mammographic images were acquired on two mammography imaging systems (General Electric and Hologic) one year apart and processed using VolparaDensity™ to obtain the Volpara Density Grade (VDG) and average volumetric breast density percentage (AvBD%). Visual BIRADS scores were also obtained from 20 expert readers. BIRADS scores for both systems showed strong positive correlation ([Formula: see text]; [Formula: see text]), while the VDG ([Formula: see text]; [Formula: see text]) and AvBD% ([Formula: see text]; [Formula: see text]) showed stronger positive correlations. Substantial agreement was shown between the systems for BIRADS ([Formula: see text]; [Formula: see text]), however, the systems demonstrated an almost perfect agreement for VDG ([Formula: see text]; [Formula: see text]).

  13. Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max; Sherman, Max H.; Walker, Iain S.

    2008-05-01

    The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix the air thus the indoor conditions between zones. Different types of ventilation systems will provide different amounts of exposure depending on the effectiveness of their air distribution systems and the location of sources and occupants. This paper will report on field measurements using a unique multi-tracer measurement system that has the capacity to measure not only the flow of outdoor air to each zone, but zone-to-zone transport. The paper will derive seven different metrics for the evaluation of air distribution. Measured data from two homes with different levels of natural infiltration will be used to evaluate these metrics for three different ASHRAE Standard 62.2 compliant ventilation systems. Such information can be used to determine the effectiveness of different systems so that appropriate adjustments can be made in residential ventilation standards such as ASHRAE Standard 62.2.

  14. Interferometric system with tracking refractometry capability in the measuring axis

    International Nuclear Information System (INIS)

    Lazar, J; Holá, M; Číp, O; Hrabina, J; Oulehla, J

    2013-01-01

    We present a combined interferometric arrangement designed for measurement of one-axis displacement over a specified measuring range with mechanical referencing. This concept allows simultaneous measurement of the carriage position from both sides together with monitoring of the overall range. This can be used in configuration with in-line monitoring of the fluctuations of the refractive index-–tracking refractometry. Similarly, the wavelength of the laser source can be stabilized over the measuring range, effectively compensating for the refractive index changes. Otherwise, monitoring of length of the measuring range can give information about the thermal dilatation effects of frame of the whole measuring setup. This technique can find its way into high-precision positioning systems in nanometrology. (technical design note)

  15. Color speckle measurement errors using system with XYZ filters

    Science.gov (United States)

    Kinoshita, Junichi; Yamamoto, Kazuhisa; Kuroda, Kazuo

    2018-02-01

    Measurement errors of color speckle are analyzed for a measurement system equipped with revolving XYZ filters and a 2D sensor. One of the errors is caused by the filter characteristics unfitted to the ideal color matching functions. The other is caused by uncorrelations among the optical paths via the XYZ filters. The unfitted color speckle errors of all the pixel data can be easily calibrated by conversion between the measured BGR chromaticity triangle and the true triangle obtained by the BGR wavelength measurements. For the uncorrelated errors, the measured BGR chromaticity values spread over around the true values. As a result, it would be more complicated to calibrate the uncorrelated errors, repeating the triangular conversion pixel by pixel. Color speckle and its errors greatly affect also chromaticity measurements and image quality of displays using coherent light sources.

  16. Reliability centered operational performance measure for computer systems in NPPs

    International Nuclear Information System (INIS)

    Khobare, S.K.; Chandra, Umesh; Govindarajan, G.

    1992-01-01

    There could be arguments in favour and against the application of digital computers in highly safety critical plants like nuclear power plants (NPPs). The unfavourable arguments arise mainly due to grey areas in accurate assessment, demonstration of the required reliability and availability of computer systems. This requirement is important particularly for computer applications in control and protection logic systems of the NPPs. Systematic performance comparison study is required to be made for these applications against the conventional hard wired logic systems. The present paper discusses reliability centered system and plant performance measures to analyse the gains of computer applications in the NPPs. (author). 5 refs. 2 tabs

  17. Geometrical calibration television measuring systems with solid state photodetectors

    Science.gov (United States)

    Matiouchenko, V. G.; Strakhov, V. V.; Zhirkov, A. O.

    2000-11-01

    The various optical measuring methods for deriving information about the size and form of objects are now used in difference branches- mechanical engineering, medicine, art, criminalistics. Measuring by means of the digital television systems is one of these methods. The development of this direction is promoted by occurrence on the market of various types and costs small-sized television cameras and frame grabbers. There are many television measuring systems using the expensive cameras, but accuracy performances of low cost cameras are also interested for the system developers. For this reason inexpensive mountingless camera SK1004CP (format 1/3', cost up to 40$) and frame grabber Aver2000 were used in experiments.

  18. Research on Accuracy of Automatic System for Casting Measuring

    Directory of Open Access Journals (Sweden)

    Jaworski J.

    2016-09-01

    Full Text Available Ensuring the required quality of castings is an important part of the production process. The quality control should be carried out in a fast and accurate way. These requirements can be met by the use of an optical measuring system installed on the arm of an industrial robot. In the article a methodology for assessing the quality of robotic measurement system to control certain feature of the casting, based on the analysis of repeatability and reproducibility is presented. It was shown that industrial robots equipped with optical measuring systems have the accuracy allowing their use in the process of dimensional control of castings manufactured by lost-wax process, permanent-mould casting, and pressure die-casting.

  19. System of measurement of proton polarization in a polarized target

    Energy Technology Data Exchange (ETDEWEB)

    Karnaukov, I.M.; Chechetenko, V.F.; Lukhanin, A.A.; Telegin, Y.N.; Trotsenko, V.I.

    1985-05-01

    This paper describes a nuclear magnetic resonance spectrometer with high sensitivity. The signal of NMR absorption is recorded by a Q-meter with a series circuit and a circuit for compensation of the resonance characteristic of the measuring circuit. In order to ensure uniform sensitivity of the system to the state of polarization throughout the volume of the target and to enhance the S/N ration the measuring coil is made of a flat conductor. The polarization-measuring system works on-line with an M-6000 computer. The total error of measurement of the polarization of free protons in a target with allowance for the error due to local depolarization of free protons in a target with allowance for the error due to local depolarization of the working substance under irradiation with an intense photon beam is less than or equal to 6%.

  20. [A focused sound field measurement system by LabVIEW].

    Science.gov (United States)

    Jiang, Zhan; Bai, Jingfeng; Yu, Ying

    2014-05-01

    In this paper, according to the requirement of the focused sound field measurement, a focused sound field measurement system was established based on the LabVIEW virtual instrument platform. The system can automatically search the focus position of the sound field, and adjust the scanning path according to the size of the focal region. Three-dimensional sound field scanning time reduced from 888 hours in uniform step to 9.25 hours in variable step. The efficiency of the focused sound field measurement was improved. There is a certain deviation between measurement results and theoretical calculation results. Focal plane--6 dB width difference rate was 3.691%, the beam axis--6 dB length differences rate was 12.937%.

  1. Discrete time interval measurement system: fundamentals, resolution and errors in the measurement of angular vibrations

    International Nuclear Information System (INIS)

    Gómez de León, F C; Meroño Pérez, P A

    2010-01-01

    The traditional method for measuring the velocity and the angular vibration in the shaft of rotating machines using incremental encoders is based on counting the pulses at given time intervals. This method is generically called the time interval measurement system (TIMS). A variant of this method that we have developed in this work consists of measuring the corresponding time of each pulse from the encoder and sampling the signal by means of an A/D converter as if it were an analog signal, that is to say, in discrete time. For this reason, we have denominated this method as the discrete time interval measurement system (DTIMS). This measurement system provides a substantial improvement in the precision and frequency resolution compared with the traditional method of counting pulses. In addition, this method permits modification of the width of some pulses in order to obtain a mark-phase on every lap. This paper explains the theoretical fundamentals of the DTIMS and its application for measuring the angular vibrations of rotating machines. It also displays the required relationship between the sampling rate of the signal, the number of pulses of the encoder and the rotating velocity in order to obtain the required resolution and to delimit the methodological errors in the measurement

  2. Study on a transient optical fiber high temperature measurement system

    Science.gov (United States)

    Cai, Lulu; Liu, Yusha; Wang, Yutian

    2009-07-01

    High temperature is one of the most important parameters in the fields of scientific research and industrial production. At present, thermocouple, thermo resistive and radiance thermometer are already technologically mature which can be adopted to measure the general temperature, but when it comes to the transient high temperature that changes pretty quickly in wretched conditions, those traditional pyrometers can not meet the requirements any more. In this paper, we designed a transient optical high temperature measurement system. First, design of the temperature measurement probe. The system took blackbody cavity sensor together with optical fiber to receive the measured signal, here, the integrated emissivity model of the blackbody cavity was established and the optimum structure parameters were confirmed. Secondly, design of the entire temperature measurement system. A contact-noncontact measurement method was applied, which is to make the blackbody cavity and the measured high-temperature source contact, the fiber probe and the blackbody cavity noncontact, as a result, the error caused by contact measurement is overcame and the precision is guaranteed at the same time. In addition, a fiber grating was introduced as the wavelength filter device which can realize the dynamic filter of narrow-band signals and reduce the impact of background light. Thirdly, signal processing. In this part, we applied labVIEW software and wavelet analysis method. All of the signal acquisition and processing were realized in the labVIEW environment. Through calling matlab in labVIEW, the signals from optical fiber detector were wavelet denoised and decomposed, thus the temperature information was extracted, and the temperature value was obtained. On basis of wavelet transformation, the paper adopted the 4dB wavelet with horizontal scale of 5 to realize the feature extraction and noise removal, parts of the signals before and after the wavelet noise removal were given and analyzed

  3. SLC Arc transport system: AG-magnet measurement and performance

    International Nuclear Information System (INIS)

    Weng, W.T.; Anderson, M.; Byers, R.; Cobb, J.; Fischer, G.; Hamilton, V.

    1985-03-01

    This paper describes the design, construction, and operation of devices used to rapidly measure the mechanical and magnetic properties of some 950 Alternate gradient magnets used in the arc system of the Stanford Linear Collider. The problems of dealing with the measurement of the transverse dimensions to within minute (0.0001 in.) resolution of objects that are 8 ft long are discussed. Early results from the production runs of these magnets are presented. 7 refs., 6 figs

  4. Online high sensitivity measurement system for transuranic aerosols

    International Nuclear Information System (INIS)

    Kordas, J.F.; Phelps, P.L.

    1976-01-01

    A measurement system for transuranic aerosols has been designed that will be able to withstand the corrosive nature of stack effluents and yet have extremely high sensitivity. It will be capable of measuring 1 maximum permissible concentration (MPC) of plutonium or americium in 30 minutes with a fractional standard deviation of less than 0.33. Background resulting from 218 Po is eliminated by alpha energy discrimination and a decay scheme analysis. A microprocessor controls all data acquisition, data reduction, and instrument calibration

  5. Floating data acquisition system for microwave calorimeter measurements on MTX

    International Nuclear Information System (INIS)

    Sewall, N.R.

    1989-01-01

    A microwave calorimeter has been designed for making 140-GHz absorption measurements on the MTX. Measurement of the intensity and spatial distribution of the FEL-generated microwave beam on the inner wall will indicate the absorption characteristics of the plasma when heated with a 140 GHz FEL pulse. The calorimeter works by monitoring changes of temperature in silicon carbide tiles located on the inner wall of the tokamak. Thermistors are used to measure the temperature of each tile. The tiles are located inside the tokamak about 1 cm outside of the limiter radius at machine potential. The success of this measurement depends on our ability to float the data acquisition system near machine potential and isolate it from the rest of the vault ground system. Our data acquisition system has 48 channels of thermistor signal conditioning, a multiplexer and digitizer section, a serial data formatter, and a fiber-optic transmitter to send the data out. Additionally, we bring timing signals to the interface through optical fibers to tell it when to begin measurement, while maintaining isolation. The receiver is an HP 200 Series computer with a serial data interface; the computer provides storage and local display for the shot temperature profile. Additionally, the computer provides temporary storage of the data until it can be passed to a shared resource management system for archiving. 2 refs., 6 figs

  6. Floating data acquisition system for microwave calorimeter measurements on MTX

    International Nuclear Information System (INIS)

    Sewall, N.R.; Meassick, S.

    1989-01-01

    A microwave calorimeter has been designed for making 140-GHz absorption measurements on the MTX. Measurement of the intensity and spatial distribution of the FEL-generated microwave beam on the inner wall will indicate the absorption characteristics of the plasma when heated with a 140 GHz FEL pulse. The calorimeter works by monitoring changes of temperature in silicon carbide tiles located on the inner wall of the tokamak. Thermistors are used to measure the temperature of each tile. The tiles are located inside the tokamak about 1 cm outside of the limiter radius at machine potential. The success of this measurement depends on our ability to float the data acquisition system near machine potential and isolate it from the rest of the vault ground system. Our data acquisition system has 48 channels of thermistor signal conditioning, a multiplexer and digitizer section, a serial data formatter, and a fiber-optic transmitter to send the data out. Additionally, we bring timing signals to the interface through optical fibers to tell it when to begin measurement, while maintaining isolation. The receiver is an HP 200 series computer with a serial data interface; the computer provides storage and local display for the shot temperature profile. Additionally, the computer provides temporary storage of the data until it can be passed to a shared resource management system for archiving. 2 refs., 6 figs

  7. Real-Time Measurements for Adaptive and Cognitive Radio Systems

    Directory of Open Access Journals (Sweden)

    Hüseyin Arslan

    2009-01-01

    Full Text Available Adaptive and cognitive radios (CR have been becoming popular for optimizing mobile radio system transmission and reception. One of the most important elements of the adaptive radio and CR concepts is the ability to measure, sense, learn about, and be aware of parameters related to the radio channel characteristics, availability of spectrum and power, interference and noise temperature, operational environment of radio, user requirements and applications, available networks and infrastructures, local policies, other operating restrictions, and so on. This paper discusses some of the important measurement parameters for enabling adaptive radio and CR systems along with their relationships and impacts on the performance including relevant challenges.

  8. Surface moisture measurement system hardware acceptance test report

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, G.A., Westinghouse Hanford

    1996-05-28

    This document summarizes the results of the hardware acceptance test for the Surface Moisture Measurement System (SMMS). This test verified that the mechanical and electrical features of the SMMS functioned as designed and that the unit is ready for field service. The bulk of hardware testing was performed at the 306E Facility in the 300 Area and the Fuels and Materials Examination Facility in the 400 Area. The SMMS was developed primarily in support of Tank Waste Remediation System (TWRS) Safety Programs for moisture measurement in organic and ferrocyanide watch list tanks.

  9. System and method for measuring fluorescence of a sample

    Energy Technology Data Exchange (ETDEWEB)

    Riot, Vincent J

    2015-03-24

    The present disclosure provides a system and a method for measuring fluorescence of a sample. The sample may be a polymerase-chain-reaction (PCR) array, a loop-mediated-isothermal amplification array, etc. LEDs are used to excite the sample, and a photodiode is used to collect the sample's fluorescence. An electronic offset signal is used to reduce the effects of background fluorescence and the noises from the measurement system. An integrator integrates the difference between the output of the photodiode and the electronic offset signal over a given period of time. The resulting integral is then converted into digital domain for further processing and storage.

  10. System and method for measuring fluorescence of a sample

    Energy Technology Data Exchange (ETDEWEB)

    Riot, Vincent J.

    2017-06-27

    The present disclosure provides a system and a method for measuring fluorescence of a sample. The sample may be a polymerase-chain-reaction (PCR) array, a loop-mediated-isothermal amplification array, etc. LEDs are used to excite the sample, and a photodiode is used to collect the sample's fluorescence. An electronic offset signal is used to reduce the effects of background fluorescence and the noises from the measurement system. An integrator integrates the difference between the output of the photodiode and the electronic offset signal over a given period of time. The resulting integral is then converted into digital domain for further processing and storage.

  11. A microprocessor based picture analysis system for automatic track measurements

    International Nuclear Information System (INIS)

    Heinrich, W.; Trakowski, W.; Beer, J.; Schucht, R.

    1982-01-01

    In the last few years picture analysis became a powerful technique for measurements of nuclear tracks in plastic detectors. For this purpose rather expensive commercial systems are available. Two inexpensive microprocessor based systems with different resolution were developed. The video pictures of particles seen through a microscope are digitized in real time and the picture analysis is done by software. The microscopes are equipped with stages driven by stepping motors, which are controlled by separate microprocessors. A PDP 11/03 supervises the operation of all microprocessors and stores the measured data on its mass storage devices. (author)

  12. A review of definitions and measures of system resilience

    International Nuclear Information System (INIS)

    Hosseini, Seyedmohsen; Barker, Kash; Ramirez-Marquez, Jose E.

    2016-01-01

    Modeling and evaluating the resilience of systems, potentially complex and large-scale in nature, has recently raised significant interest among both practitioners and researchers. This recent interest has resulted in several definitions of the concept of resilience and several approaches to measuring this concept, across several application domains. As such, this paper presents a review of recent research articles related to defining and quantifying resilience in various disciplines, with a focus on engineering systems. We provide a classification scheme to the approaches in the literature, focusing on qualitative and quantitative approaches and their subcategories. Addressed in this review are: an extensive coverage of the literature, an exploration of current gaps and challenges, and several directions for future research. - Highlights: • A comprehensive review of definitions and measures of system resilience. • Focus given to resilience in engineering systems is provided. • Nearly 150 articles across several domains are reviewed. • Future directions in resilience research are discussed.

  13. The realization of temperature controller for small resistance measurement system

    Science.gov (United States)

    Sobecki, Jakub; Walendziuk, Wojciech; Idzkowski, Adam

    2017-08-01

    This paper concerns the issues of construction and experimental tests of a temperature stabilization system for small resistance increments measurement circuits. After switching the system on, a PCB board heats up and the long-term temperature drift altered the measurement result. The aim of this work is reducing the time of achieving constant nominal temperature by the measurement system, which would enable decreasing the time of measurements in the steady state. Moreover, the influence of temperatures higher than the nominal on the measurement results and the obtained heating curve were tested. During the working process, the circuit heats up to about 32 °C spontaneously, and it has the time to reach steady state of about 1200 s. Implementing a USART terminal on the PC and an NI USB-6341 data acquisition card makes recording the data (concerning temperature and resistance) in the digital form and its further processing easier. It also enables changing the quantity of the regulator settings. This paper presents sample results of measurements for several temperature values and the characteristics of the temperature and resistance changes in time as well as their comparison with the output values. The object identification is accomplished due to the Ziegler-Nichols method. The algorithm of determining the step characteristics parameters and examples of computations of the regulator settings are included together with example characteristics of the object regulation.

  14. Guide to Flow Measurement for Electric Propulsion Systems

    Science.gov (United States)

    Frieman, Jason D.; Walker, Mitchell L. R.; Snyder, Steve

    2013-01-01

    In electric propulsion (EP) systems, accurate measurement of the propellant mass flow rate of gas or liquid to the thruster and external cathode is a key input in the calculation of thruster efficiency and specific impulse. Although such measurements are often achieved with commercial mass flow controllers and meters integrated into propellant feed systems, the variability in potential propellant options and flow requirements amongst the spectrum of EP power regimes and devices complicates meter selection, integration, and operation. At the direction of the Committee on Standards for Electric Propulsion Testing, a guide was jointly developed by members of the electric propulsion community to establish a unified document that contains the working principles, methods of implementation and analysis, and calibration techniques and recommendations on the use of mass flow meters in laboratory and spacecraft electric propulsion systems. The guide is applicable to EP devices of all types and power levels ranging from microthrusters to high-power ion engines and Hall effect thrusters. The establishment of a community standard on mass flow metering will help ensure the selection of the proper meter for each application. It will also improve the quality of system performance estimates by providing comprehensive information on the physical phenomena and systematic errors that must be accounted for during the analysis of flow measurement data. This paper will outline the standard methods and recommended practices described in the guide titled "Flow Measurement for Electric Propulsion Systems."

  15. INFORMATION-MEASURING TEST SYSTEM OF DIESEL LOCOMOTIVE HYDRAULIC TRANSMISSIONS

    Directory of Open Access Journals (Sweden)

    I. V. Zhukovytskyy

    2015-08-01

    Full Text Available Purpose. The article describes the process of developing the information-measuring test system of diesel locomotives hydraulic transmission, which gives the possibility to obtain baseline data to conduct further studies for the determination of the technical condition of diesel locomotives hydraulic transmission. The improvement of factory technology of post-repair tests of hydraulic transmissions by automating the existing hydraulic transmission test stands according to the specifications of the diesel locomotive repair enterprises was analyzed. It is achieved based on a detailed review of existing foreign information-measuring test systems for hydraulic transmission of diesel locomotives, BelAZ earthmover, aircraft tug, slag car, truck, BelAZ wheel dozer, some brands of tractors, etc. The problem for creation the information-measuring test systems for diesel locomotive hydraulic transmission is being solved, starting in the first place from the possibility of automation of the existing test stand of diesel locomotives hydraulic transmission at Dnipropetrovsk Diesel Locomotive Repair Plant "Promteplovoz". Methodology. In the work the researchers proposed the method to create a microprocessor automated system of diesel locomotives hydraulic transmission stand testing in the locomotive plant conditions. It acts by justifying the selection of the necessary sensors, as well as the application of the necessary hardware and software for information-measuring systems. Findings. Based on the conducted analysis there was grounded the necessity of improvement the plant hydraulic transmission stand testing by creating a microprocessor testing system, supported by the experience of developing such systems abroad. Further research should be aimed to improve the accuracy and frequency of data collection by adopting the more modern and reliable sensors in tandem with the use of filtering software for electromagnetic and other interference. Originality. The

  16. A system for measuring and processing personnel dosimetric data

    International Nuclear Information System (INIS)

    Neetzel, C.R.; Rochetti, Luis

    1981-01-01

    An operative system for the measurement and on-line processing of personnel dosimetry data is described. The aim is to organize and rationalize the work involved in a personnel dosimetry service. The method considers the application to other areas of radiation protection, as well as the connection and exchange of files among the different personnel monitoring groups. The system can be interfaced with different computers (M.E.L.) [es

  17. Velocity Measurement Systems for a Low-speed Wind Tunnel

    Science.gov (United States)

    2015-04-29

    SECURITY CLASSIFICATION OF: Funds were provided by the ARO for the purchase of TSI hot-wire anemometer equipment and a Dantec particle- image...Velocity Measurement Systems for a Low-speed Wind Tunnel Report Title Funds were provided by the ARO for the purchase of TSI hot-wire anemometer equipment...Funds were provided by the Army Research Office for the purchase of TSI hot-wire anemometer equipment and a Dantec particle-image velocimetry system

  18. Diffraction measurements using the LHC Beam Loss Monitoring System

    Science.gov (United States)

    Kalliokoski, Matti

    2017-03-01

    The Beam Loss Monitoring (BLM) system of the Large Hadron Collider protects the machine from beam induced damage by measuring the absorbed dose rates of beam losses, and by triggering beam dump if the rates increase above the allowed threshold limits. Although the detection time scales are optimized for multi-turn losses, information on fast losses can be recovered from the loss data. In this paper, methods in using the BLM system in diffraction studies are discussed.

  19. AIP Diffraction measurements using the LHC Beam Loss Monitoring System

    CERN Document Server

    Kalliokoski, Matti

    2017-01-01

    The Beam Loss Monitoring (BLM) system of the Large Hadron Collider protects the machine from beam induced damage by measuring the absorbed dose rates of beam losses, and by triggering beam dump if the rates increase above the allowed threshold limits. Although the detection time scales are optimized for multi-turn losses, information on fast losses can be recovered from the loss data. In this paper, methods in using the BLM system in di ff raction studies are discussed.

  20. Upgrade of the cooling water temperature measures system for HLS

    International Nuclear Information System (INIS)

    Guo Weiqun; Liu Gongfa; Bao Xun; Jiang Siyuan; Li Weimin; He Duohui

    2007-01-01

    The cooling water temperature measures system for HLS (Hefei Light Source) adopts EPICS to the developing platform and takes the intelligence temperature cruise instrument for the front control instrument. Data of temperatures are required by IOCs through Serial Port Communication, archived and searched by Channel Archiver. The system can monitor the real-time temperatures of many channels cooling water and has the function of history data storage, and data network search. (authors)

  1. Simultaneous Authentication and Certification of Arms-Control Measurement Systems

    Energy Technology Data Exchange (ETDEWEB)

    MacArthur, Duncan W. [Los Alamos National Laboratory; Hauck, Danielle K. [Los Alamos National Laboratory; Thron, Jonathan L. [Los Alamos National Laboratory

    2012-07-09

    Most arms-control-treaty-monitoring scenarios involve a host party that makes a declaration regarding its nuclear material or items and a monitoring party that verifies that declaration. A verification system developed for such a use needs to be trusted by both parties. The first concern, primarily from the host party's point of view, is that any sensitive information that is collected must be protected without interfering in the efficient operation of the facility being monitored. This concern is addressed in what can be termed a 'certification' process. The second concern, of particular interest to the monitoring party, is that it must be possible to confirm the veracity of both the measurement system and the data produced by this measurement system. The monitoring party addresses these issues during an 'authentication' process. Addressing either one of these concerns independently is relatively straightforward. However, it is more difficult to simultaneously satisfy host party certification concerns and monitoring party authentication concerns. Typically, both parties will want the final access to the measurement system. We will describe an alternative approach that allows both parties to gain confidence simultaneously. This approach starts with (1) joint development of the measurement system followed by (2) host certification of several copies of the system and (3) random selection by the inspecting party of one copy to be use during the monitoring visit and one (or more) copy(s) to be returned to the inspecting party's facilities for (4) further hardware authentication; any remaining copies are stored under joint seal for use as spares. Following this process, the parties will jointly (5) perform functional testing on the selected measurement system and then (6) use this system during the monitoring visit. Steps (1) and (2) assure the host party as to the certification of whichever system is eventually used in the monitoring visit

  2. Integration Of GPS And GLONASS Systems In Geodetic Satellite Measurements

    Science.gov (United States)

    Maciuk, Kamil

    2015-12-01

    The article shows the results of satellites measurements elaborations using GPS & GLONASS signals. The aim of this article is to define the influence of adding GLONASS signals on position determination accuracy. It especially concerns areas with big horizon coverages. Object of the study were analysis of DOP coefficients, code and RTK solutions, and usage of satellite techniques in levelling. The performed studies and analysis show that integrated GPS-GLONASS satellite measurements provide possibility to achieve better results than measurements using single navigation satellite system (GPS).

  3. Squeezing-enhanced measurement sensitivity in a cavity optomechanical system

    DEFF Research Database (Denmark)

    Kerdoncuff, Hugo; Hoff, Ulrich Busk; Harris, Glen I.

    2015-01-01

    We determine the theoretical limits to squeezing-enhanced measurement sensitivity of mechanical motion in a cavity optomechanical system. The motion of a mechanical resonator is transduced onto quadrature fluctuations of a cavity optical field and a measurement is performed on the optical field...... exiting the cavity. We compare measurement sensitivities obtained with coherent probing and quantum-enhanced probing of the mechanical motion, i.e. the coherent probe field carries vacuum states and quadrature squeezed vacuum states at sideband frequencies, respectively. We find that quantum...

  4. Management system of in vivo reports of activity measurements

    International Nuclear Information System (INIS)

    Castro, R.C.; Dantas, A.L.A.; Lourenco, M.C.; Dantas, B.M.

    2005-01-01

    The SGRIMA (management system of in vivo reports of activity measurements) is a software for Windows developed specifically for the Laboratory of In Vivo Measurements of the IRD - Brazilian Institute for Radioprotection and Dosimetry -, in order to manage the individual monitoring process that includes personal data archiving, data relating to the parameters of each measure and calculation results of activity. The software was developed in MS Visual Basic 6, using a MS Access database and can be run on personal computers with MS Windows 98 or higher

  5. Particle emission measurement campaign for biomass heating systems. Final report

    International Nuclear Information System (INIS)

    2009-10-01

    This study aims at assessing the energetic and environmental performance of operating biomass heating systems, more particularly with respect to regulatory and required limit values of particle emissions. The measurement campaign concerned 14 biomass heating installations of less than 4 MW equipped with either a cyclone-type de-duster, or a sleeve filter, or electro-filters. The report discusses the measured parameters (wood and ash analysis, atmospheric releases) and the applied methodology (sampling and measurements). It describes the methodology used to compute energetic and environmental performance (efficiency, load rate, emission factors), and finally discusses the obtained results

  6. System for measurements and data processing in neutron physics researches

    International Nuclear Information System (INIS)

    Kadashevich, V.I.; Kondurov, I.A.; Nikolaev, S.N.; Ryabov, Yu.F.

    1976-01-01

    A system of measuring and computing means created for automation of studies in the field of the neutron physics is discussed. Within the framework of this system each experiment is provided with its individual measuring station which consists of a set of analog and digital modules implemented in accordance with the CAMAC standard. On the higher level of this system there are measuring-computing centres (MCC) which simultaneously serve a number of physical installations. These MCCs are based on ''Minsk-22'' computers whose computational facilities are used for the preliminary processing and for creation of temporary data archives. In its turn, all the MCCs are users of the time-sharing system on the basis of the ''Minsk-32'' computers. This system extends possibilities for user's fast data processing, archive creation and provides transfer of required information to the main computing system based on the BESM-6 computer. Transfer of information and preliminary processing are performed by remote terminals with the help of a special directive language

  7. System to Measure Thermal Conductivity and Seebeck Coefficient for Thermoelectrics

    Science.gov (United States)

    Kim, Hyun-Jung; Skuza, Jonathan R.; Park, Yeonjoon; King, Glen C.; Choi, Sang H.; Nagavalli, Anita

    2012-01-01

    The Seebeck coefficient, when combined with thermal and electrical conductivity, is an essential property measurement for evaluating the potential performance of novel thermoelectric materials. However, there is some question as to which measurement technique(s) provides the most accurate determination of the Seebeck coefficient at elevated temperatures. This has led to the implementation of nonstandardized practices that have further complicated the confirmation of reported high ZT materials. The major objective of the procedure described is for the simultaneous measurement of the Seebeck coefficient and thermal diffusivity within a given temperature range. These thermoelectric measurements must be precise, accurate, and reproducible to ensure meaningful interlaboratory comparison of data. The custom-built thermal characterization system described in this NASA-TM is specifically designed to measure the inplane thermal diffusivity, and the Seebeck coefficient for materials in the ranging from 73 K through 373 K.

  8. A laboratory goniometer system for measuring reflectance and emittance anisotropy.

    Science.gov (United States)

    Roosjen, Peter P J; Clevers, Jan G P W; Bartholomeus, Harm M; Schaepman, Michael E; Schaepman-Strub, Gabriela; Jalink, Henk; van der Schoor, Rob; de Jong, Arjan

    2012-12-13

    In this paper, a laboratory goniometer system for performing multi-angular measurements under controlled illumination conditions is described. A commercially available robotic arm enables the acquisition of a large number of measurements over the full hemisphere within a short time span making it much faster than other goniometers. In addition, the presented set-up enables assessment of anisotropic reflectance and emittance behaviour of soils, leaves and small canopies. Mounting a spectrometer enables acquisition of either hemispherical measurements or measurements in the horizontal plane. Mounting a thermal camera allows directional observations of the thermal emittance. This paper also presents three showcases of these different measurement set-ups in order to illustrate its possibilities. Finally, suggestions for applying this instrument and for future research directions are given, including linking the measured reflectance anisotropy with physically-based anisotropy models on the one hand and combining them with field goniometry measurements for joint analysis with remote sensing data on the other hand. The speed and flexibility of the system offer a large added value to the existing pool of laboratory goniometers.

  9. Mixing measures in non-conservative transport systems

    Science.gov (United States)

    Engdahl, N. B.; Fogg, G. E.

    2012-12-01

    Predictions of the fate of reactive solutes in porous media are often made by using the mixing state of the system to determine effective reaction rates. This approach can be useful when the mixing measure accurately characterizes the behavior of the solutes, but, in many cases, the behavior of the mixing measure depends on the reaction system itself. Quantifying mixing is further complicated because the mixing measures often require complete knowledge of the concentration field which is never available in practice. Here we investigate the behavior of the scalar dissipation rate, the dilution index, the variance, and total solute mass in non-conservative transport systems for three component kinetic reactions in large, but finite, monitoring areas. The effects of different reaction rates, mass transfer, mobility, and different initial conditions are considered for these mixing measures. Mass transfer can cause a delay in the time required for the reaction system to reach an equilibrium state, and the magnitude of the delay depends on the mass transfer rate. The effects of this multi-step equilibrium process can manifest contrarily for different mixing measures, and these effects are amplified when the reaction product is immobile. For precipitation-dissolution reactions, the mass transfer rate may depend on the concentration of an immobile precipitate. This process causes sharp transitions in the mixing measures that are the result of a lingering chemical disequilibrium, caused by the concentration dependent mass transfer rates. The immobile domain and the initial conditions can have strong effects on the mixing state for long times, and, without knowledge of immobile concentrations, these effects could easily be attributed to measurement errors.

  10. Software Sub-system in Loading Automatic Test System for the Measurement of Power Line Filters

    Directory of Open Access Journals (Sweden)

    Yu Bo

    2017-01-01

    Full Text Available The loading automatic test system for measurement of power line filters are in urgent demand. So the software sub-system of the whole test system was proposed. Methods: structured the test system based on the virtual instrument framework, which consisted of lower and up computer and adopted the top down approach of design to perform the system and its modules, according to the measurement principle of the test system. Results: The software sub-system including human machine interface, data analysis and process software, expert system, communication software, control software in lower computer, etc. had been designed. Furthermore, it had been integrated into the entire test system. Conclusion: This sub-system provided a fiendly software platform for the whole test system, and had many advantages such as strong functions, high performances, low prices. It not only raises the test efficiency of EMI filters, but also renders some creativities.

  11. Global Precipitation Measurement (GPM) Mission: NASA Precipitation Processing System (PPS)

    Science.gov (United States)

    Stocker, Erich Franz

    2008-01-01

    NASA is contributing the precipitation measurement data system PPS to support the GPM mission. PPS will distribute all GPM data products including NASA s GMI data products freely and quickly. PPS is implementing no system mechanisms for restricting access to GPM data. PPS is implementing no system mechanisms for charging for GPM data products. PPS will provide a number of geographical and parameter subsetting features available to its users. The first implementation of PPS (called PPS--) will assume processing of TRMM data effective 1 June 2008. TRMM realtime data will be available via PPS- to all users requesting access

  12. Real-time deformation measurement using a transportable shearography system

    Science.gov (United States)

    Weijers, A. L.; van Brug, Hedser H.; Frankena, Hans J.

    1997-03-01

    A new system for deformation visualization has been developed, being a real time phase stepped shearing speckle interferometer. This system provides the possibility to measure quantitatively deformations of diffusely reflecting objects in an industrial environment. The main characteristics of this interferometer are its speed of operation and its reduced sensitivity to external disturbances. Apart from its semiconductor laser source, this system has a shoe-box size and is mounted on a tripod for easy handling during inspection. This paper describes the shearing speckle interferometry set-up, as it is developed at our laboratory and its potential for detecting defects.

  13. Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS)

    Energy Technology Data Exchange (ETDEWEB)

    Bland, Geoffrey [NASA Goddard Space Flight Center (GSFC), Greenbelt, MD (United States)

    2016-06-30

    The use of small unmanned aircraft systems (sUAS) with miniature sensor systems for atmospheric research is an important capability to develop. The Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems (ERASMUS) project, lead by Dr. Gijs de Boer of the Cooperative Institute for Research in Environmental Sciences (CIRES- a partnership of NOAA and CU-Boulder), is a significant milestone in realizing this new potential. This project has clearly demonstrated that the concept of sUAS utilization is valid, and miniature instrumentation can be used to further our understanding of the atmospheric boundary layer in the arctic.

  14. On-board system for physical and microphysical measurements

    International Nuclear Information System (INIS)

    Ravaut, M.; Allet, C.; Dole, B.; Gribkoff, A.; Schibler, P.; Charpentier, C.

    1981-10-01

    This report presents the system of physical and microphysical measurement instrumentation on board the HUREL-DUBOIS HD 34 aircraft, built in cooperation with the Institut National d'Astronomie et de Geophysique (I.N.A.G.) and the Institut Geographique National (I.G.N.). The feasibility study of the system was carried out in the first half of 1978 and took shape in an on-site proving campaign in November 1979. As a result, the on-board system was able to participate in the BUGEY experimental campaign of March 1980, a glimpse of which is given in this report [fr

  15. Independent measuring station for the GNEJS neutron spectrometer information and measurement system

    International Nuclear Information System (INIS)

    Gorokhov, I.S.; Laptev, A.B.; Marchenkov, V.V.; Tubol'tsev, Yu.V.; Fokin, E.Yu.; Shcherbakov, O.A.

    1984-01-01

    An independent measuring station (IMS) being a part of the information and measuring system of the neutron time-of-flight spectrometer is described. IMS represents the time (time-to-amplitude or time-to-angular) module analyzer assembled on the base of one or several CAMAC crates. The station permits to perform time measurements as well as the time measurements with amplitude weighing in an independent mode with subseqUent data transmission the central PDP-11/05 computer. The station processor unit is an independent controller. The software consists of the programming langUage of the controller from local terminal and programs ensuring measuring and shaping the spectra with their output on TV display devic. communication with the computer and dialogue with the operator

  16. Designing a performance measurement system: A case study

    NARCIS (Netherlands)

    Lohman, Clemens; Fortuin, Leonard; Wouters, Marc

    2004-01-01

    Performance measurement (PM) by means of local performance indicators (PIs) is developing into performance management at a company-wide scale. But how should PIs at various levels in the organization be incorporated into one system that can help managers, working at levels that range from

  17. gLite Workload Management System Performance Measurements

    CERN Document Server

    Svraka, N; Belic, A; Bogojevic, A R

    2006-01-01

    In this paper an introduction to the gLite Grid middleware and one of its most important components, Workload Management System (WMS), responsible for management of user jobs is given.Useful performance metrics of gLite WMS are defined from a Grid application point of view, and preliminary results of performance measurements are presented and briefly analyzed.

  18. A High-Precision Capacitive Sensor System for Displacement Measurements

    NARCIS (Netherlands)

    Yang, R.

    2015-01-01

    This thesis presents the theory, design and qualification of a precision capacitive sensor system for displacement measurement that require high resolution, high precision and simultaneously, low power consumption. The challenge to achieve the required performance has been taken care at both

  19. Measuring and recording system for electron beam welding parameters

    International Nuclear Information System (INIS)

    Lobanova, N.G.; Lifshits, M.L.; Efimov, I.I.

    1987-01-01

    The observation possibility during electron beam welding of circular articles with guaranteed clearance of welding bath leading front in joint gap and flare cloud over the bath by means of television monitor is considered. The composition and operation mode of television measuring system for metric characteristics of flare cloud and altitude of welding bath leading front in the clearance are described

  20. Improving Teacher Evaluation Systems: Making the Most of Multiple Measures

    Science.gov (United States)

    Grissom, Jason A., Ed.; Youngs, Peter, Ed.

    2015-01-01

    This is the first book to gather and address what we have learned about the impacts and challenges of data-intensive teacher evaluation systems--a defining characteristic of the current education policy landscape. Expert researchers and practitioners speak to what we know (and what remains to be known) about evaluation measures themselves, the…

  1. 77 FR 20789 - Work Group on Measuring Systems for Taxis

    Science.gov (United States)

    2012-04-06

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF COMMERCE National Institute of Standards and Technology Work Group on Measuring Systems for Taxis AGENCY: National... Standards and Technology (NIST) is forming a Work Group (WG) to develop proposals to revise the current...

  2. Automatic Measuring System for Oil Stream Paraffin Deposits Parameters

    Science.gov (United States)

    Kopteva, A. V.; Koptev, V. Yu

    2018-03-01

    This paper describes a new method for monitoring oil pipelines, as well as a highly efficient and automated paraffin deposit monitoring method. When operating oil pipelines, there is an issue of paraffin, resin and salt deposits on the pipeline walls that come with the oil stream. It ultimately results in frequent transportation suspension to clean or even replace pipes and other equipment, thus shortening operation periods between repairs, creating emergency situations and increasing production expenses, badly affecting environment, damaging ecology and spoil underground water, killing animals, birds etc. Oil spills contaminate rivers, lakes, and ground waters. Oil transportation monitoring issues are still subject for further studying. Thus, there is the need to invent a radically new automated process control and management system, together with measurement means intellectualization. The measurement principle is based on the Lambert-Beer law that describes the dependence between the gamma-radiation frequency and the density together with the linear attenuation coefficient for a substance. Using the measuring system with high accuracy (± 0,2%), one can measure the thickness of paraffin deposits with an absolute accuracy of ± 5 mm, which is sufficient to ensure reliable operation of the pipeline system. Safety is a key advantage, when using the proposed control system.

  3. A Computer Controlled Precision High Pressure Measuring System

    Science.gov (United States)

    Sadana, S.; Yadav, S.; Jha, N.; Gupta, V. K.; Agarwal, R.; Bandyopadhyay, A. K.; Saxena, T. K.

    2011-01-01

    A microcontroller (AT89C51) based electronics has been designed and developed for high precision calibrator based on Digiquartz pressure transducer (DQPT) for the measurement of high hydrostatic pressure up to 275 MPa. The input signal from DQPT is converted into a square wave form and multiplied through frequency multiplier circuit over 10 times to input frequency. This input frequency is multiplied by a factor of ten using phased lock loop. Octal buffer is used to store the calculated frequency, which in turn is fed to microcontroller AT89C51 interfaced with a liquid crystal display for the display of frequency as well as corresponding pressure in user friendly units. The electronics developed is interfaced with a computer using RS232 for automatic data acquisition, computation and storage. The data is acquired by programming in Visual Basic 6.0. This system is interfaced with the PC to make it a computer controlled system. The system is capable of measuring the frequency up to 4 MHz with a resolution of 0.01 Hz and the pressure up to 275 MPa with a resolution of 0.001 MPa within measurement uncertainty of 0.025%. The details on the hardware of the pressure measuring system, associated electronics, software and calibration are discussed in this paper.

  4. Evaluation Of Farming Systems And Informal Insurance Measures ...

    African Journals Online (AJOL)

    It also showed that adoption of risk management techniques, marketing strategies, souring of microcredit and improving information sources simultaneously, ensured higher income. Recommendations include encouraging farmers to adopt the most profitable farming systems and informal insurance measures as well as ...

  5. Multiple Measures Accountability Systems: A Perspective from Vermont

    Science.gov (United States)

    Fowler, Amy

    2018-01-01

    In response to Bae's (2018) "Redesigning systems of school accountability: A multiple measures approach to accountability and support," this commentary expands on some key considerations for states and school districts as they seek different ways to support school improvement while also addressing the competing demands of educators,…

  6. Adapting Accountability Systems to the Limitations of Educational Measurement

    Science.gov (United States)

    Kane, Michael

    2015-01-01

    Michael Kane writes in this article that he is in more or less complete agreement with Professor Koretz's characterization of the problem outlined in the paper published in this issue of "Measurement." Kane agrees that current testing practices are not adequate for test-based accountability (TBA) systems, but he writes that he is far…

  7. Geographical information system for radon gas from soil measurement

    International Nuclear Information System (INIS)

    Orlando, P.; Amici, M.; Altieri, A.; Massari, P.; Miccadei, E.; Onofri, A.; Orlando, C.; Paolelli, C.; Paron, P.; Perticaroli, P.; Piacentini, T.; Silvestri, C.; Minach, L.; Verdi, L.; Bertolo, A.; Trotti, F.

    2000-03-01

    The working program foresees the realization of an geographical information system for the check in field of the geological parameters and determination of uranium and radium contents in various type of rocks. It is here also pointed out a measuring method for radon concentration in soil [it

  8. Performance evaluation using periodic system-state measurements

    NARCIS (Netherlands)

    Ellens, W.; Mandjes, M.; Berg, J.L. van den; Worm, D.T.H.; Błaszczuk, S.

    2015-01-01

    This paper deals with the problem of inferring short time-scale fluctuations of a system's behavior from periodic state measurements. In particular, we devise a novel, efficient procedure to compute four interesting performance metrics for a transient birth-death process on an interval of fixed

  9. Parallel beam scanning system for flatness measurements of thin plates

    Science.gov (United States)

    Fan, Kuang-Chao; Wu, John H.

    1993-09-01

    This paper describes the work to develop a Parallel Beam Scanning System (PBSS) for the non-contact measurement of surface flatness of thin plates. The PBSS consists of a He-Ne laser source having good pointing stability a scanner to create divergent scanning beams a large aplanatic meniscus lens to convert the divergent beams to parallel beams a linear stage to drive the testpiece to each sampling position a screen for the projection of reflected beams from the tested surface and an image processing unit to analyze the projected image. Due to the out-of-flatness of the surface the straight line formed by the incident parallel beams will be distorted and magnified on the screen as it is reflected from the tested surface. The stage then positions the testpiece step-by-step to carry out measurements in the line-by-line sequence. A CCD camera is employed to capture the image of the distorted line on the screen each time. With the proposed mathematical model the flatness data of the testpiece can be computed from the input image data. Experimental results by the use of this system have shown in good agreement with the results obtained from the coordinate measuring machine. This system can be applied to the flatness measurements of thin plates such as sheet metals sheet moulding compound (SMC) plates glass plates etc. which are difficult to measure by traditional methods.

  10. Development of a Precise and in Situ Turbidity Measurement System

    Science.gov (United States)

    Ren, Kuanfang; Xu, Feng; Dorey, Jean-Marc; Cai, Xiaoshu

    2007-06-01

    The turbidimetry is a technique based on the transmittance spectra of the light passing through the media containing of small particles. It permits to measure the size distribution of particles for size in the range of sub-micrometer or micrometer. But the inversion problem is one of the most important obstacle for its applications. Based on the Non-negative Least Square method, we have developed stable and rapid algorithm and a measurement system permitting to the temporal acquisition (in ms) and to realize in-line measurement. To ensure its performance, the sensibility and the stability of the system have been examined in different stages: the light source, the spectrometer and the variation of the media concentration according to the optics configuration. By the measurements in the laboratory and that of the wet steam in a turbine we show that such system permits to measure very precisely the variation of the volume fraction of the particle or the wetness of wet steam.

  11. Strain sensing systems tailored for tensile measurement of fragile wires

    Science.gov (United States)

    Nyilas, Arman

    2005-12-01

    Fundamental stress versus strain measurements were completed on superconducting Nb3Sn wires within the framework of IEC/TC90 and VAMAS/TWA16. A key task was the assessment of sensing systems regarding resolution, accuracy, and precision when measuring Young's modulus. Prior to actual Nb3Sn wire measurements metallic wires, consisting of copper and stainless steel having diameters similar to the Nb3Sn wire, were extensively investigated with respect to their elastic line properties using different types of extensometers. After these calibration tests Nb3Sn wire measurements of different companies resulted in several important facts with respect to total size and weight of the used extensometers. The size could be correlated to the initial stage of stress versus strain behaviour. In fact, the effect of wire curls resulting from the production line had a profound effect on Young's modulus measurements. Within this context, the possibility of determining Young's modulus from unloading compliance lines in the plastic regime of the stress-strain curve was considered. The data obtained using this test methodology were discussed under consideration of the composite nature of Nb3Sn wire. In addition, a non-contacting sensing system based on a double-beam laser extensometer was used to investigate the potential of this new sensing system.

  12. Strain sensing systems tailored for tensile measurement of fragile wires

    International Nuclear Information System (INIS)

    Nyilas, Arman

    2005-01-01

    Fundamental stress versus strain measurements were completed on superconducting Nb 3 Sn wires within the framework of IEC/TC90 and VAMAS/TWA16. A key task was the assessment of sensing systems regarding resolution, accuracy, and precision when measuring Young's modulus. Prior to actual Nb 3 Sn wire measurements metallic wires, consisting of copper and stainless steel having diameters similar to the Nb 3 Sn wire, were extensively investigated with respect to their elastic line properties using different types of extensometers. After these calibration tests Nb 3 Sn wire measurements of different companies resulted in several important facts with respect to total size and weight of the used extensometers. The size could be correlated to the initial stage of stress versus strain behaviour. In fact, the effect of wire curls resulting from the production line had a profound effect on Young's modulus measurements. Within this context, the possibility of determining Young's modulus from unloading compliance lines in the plastic regime of the stress-strain curve was considered. The data obtained using this test methodology were discussed under consideration of the composite nature of Nb 3 Sn wire. In addition, a non-contacting sensing system based on a double-beam laser extensometer was used to investigate the potential of this new sensing system

  13. Measurement of Spray Drift with a Specifically Designed Lidar System

    Directory of Open Access Journals (Sweden)

    Eduard Gregorio

    2016-04-01

    Full Text Available Field measurements of spray drift are usually carried out by passive collectors and tracers. However, these methods are labour- and time-intensive and only provide point- and time-integrated measurements. Unlike these methods, the light detection and ranging (lidar technique allows real-time measurements, obtaining information with temporal and spatial resolution. Recently, the authors have developed the first eye-safe lidar system specifically designed for spray drift monitoring. This prototype is based on a 1534 nm erbium-doped glass laser and an 80 mm diameter telescope, has scanning capability, and is easily transportable. This paper presents the results of the first experimental campaign carried out with this instrument. High coefficients of determination (R2 > 0.85 were observed by comparing lidar measurements of the spray drift with those obtained by horizontal collectors. Furthermore, the lidar system allowed an assessment of the drift reduction potential (DRP when comparing low-drift nozzles with standard ones, resulting in a DRP of 57% (preliminary result for the tested nozzles. The lidar system was also used for monitoring the evolution of the spray flux over the canopy and to generate 2-D images of these plumes. The developed instrument is an advantageous alternative to passive collectors and opens the possibility of new methods for field measurement of spray drift.

  14. Tethered lifting systems for measurements in the lower atmosphere

    Science.gov (United States)

    Jensen, Michael Lamar

    2000-10-01

    This work defines a Tethered Lifting System for measurements in the lower atmosphere, its design and development, and applications for its use. Using historical kite research and the unique capabilities of tethered lifting platforms as motivation, a complete system has been created offering the complementary benefits of parafoil kites and tethered balloons as lifting platforms. Support systems including tethers, winching systems and payload data collection and telemetry systems round out the Tethered Lifting System to provide a complete atmospheric measurement system. The kite platforms have been enhanced by the invention and development of a wind-powered Tether Rover for Atmospheric Research (WindTRAM), providing rapid profiling and precise positioning capabilities. Design of the WindTRAM and implementation of onboard feedback control are covered in detail, as they comprise the most novel contribution of this research. The breadth of possible applications for these technologies is touched upon by examination of some of the specific research applications undertaken by the researchers at the Cooperative Institute for Research in the Environmental Sciences during the last decade.

  15. A new high rate positron lifetime measurement system

    International Nuclear Information System (INIS)

    Bedwell, M.O.; Paulus, T.J.

    1979-01-01

    Positron lifetime measuring system, a technique to perform non-destructive studies on the internal structure of materials, has many components common to those used for nuclear time spectroscopy systems. In each case, a timing coincidence curve is measured for the energy range of interest, and this is accomplished in a typical timing coincidence system. The paper first describes the conventional timing coincidence system, then a new fast timing system is introduced. Comparing to the conventional fast/slow timing system, the fast timing technique offers reduced complexity, lower system cost, and improved high data rate capability. Experimental results show that the FWHM timing resolution ranges from 190 ps for a 1.1 : 1 dynamic range to 337 ps for a 100 : 1 dynamic range of signals with 60 Co. As for the timing resolution as a function of energy, the FWHM resolution for each channel ranges from 124 ps at 1 MeV to 400 ps at 100 keV. Since the excellent timing performance is maintained even at very high input rate, the experimenters can use much more active sources to increase the true coincidence rate and reduce data accumulation time. This method has the added advantage of minimizing long term drift effects since the experiments can be conducted in less time. (Wakatsuki, Y.)

  16. Electronic system for the complex measurement of a Wilberforce pendulum

    Science.gov (United States)

    Kos, B.; Grodzicki, M.; Wasielewski, R.

    2018-05-01

    The authors present a novel application of a micro-electro-mechanical measurement system to the description of basic physical phenomena in a model Wilberforce pendulum. The composition of the kit includes a tripod with a mounted spring with freely hanging bob, a module GY-521 on the MPU 6050 coupled with an Arduino Uno, which in conjunction with a PC acts as measuring set. The system allows one to observe the swing of the pendulum in real time. Obtained data stays in good agreement with both theoretical predictions and previous works. The aim of this article is to introduce the study of a Wilberforce pendulum to the canon of physical laboratory exercises due to its interesting properties and multifaceted method of measurement.

  17. Embedded DAQ System Design for Temperature and Humidity Measurement

    Directory of Open Access Journals (Sweden)

    Tarique Rafique Memon

    2016-05-01

    Full Text Available In this work, we have proposed a cost effective DAQ (Data Acquisition system design useful for local industries by using user friendly LABVIEW (Laboratory Virtual Instrumentation Electronic Workbench. The proposed system can measure and control different industrial parameters which can be presented in graphical icon format. The system design is proposed for 8-channels, whereas tested and recorded for two parameters i.e. temperature and RH (Relative Humidity. Both parameters are set as per upper and lower limits and controlled using relays. Embedded system is developed using standard microcontroller to acquire and process the analog data and plug-in for further processing using serial interface with PC using LABVIEW. The designed system is capable of monitoring and recording the corresponding linkage between temperature and humidity in industrial unit's and indicates the abnormalities within the process and control those abnormalities through relays

  18. System, method, and apparatus for remote measurement of terrestrial biomass

    Science.gov (United States)

    Johnson, Patrick W [Jefferson, MD

    2011-04-12

    A system, method, and/or apparatus for remote measurement of terrestrial biomass contained in vegetative elements, such as large tree boles or trunks present in an area of interest, are provided. The method includes providing an airborne VHF radar system in combination with a LiDAR system, overflying the area of interest while directing energy toward the area of interest, using the VHF radar system to collect backscatter data from the trees as a function of incidence angle and frequency, and determining a magnitude of the biomass from the backscatter data and data from the laser radar system for each radar resolution cell. A biomass map is generated showing the magnitude of the biomass of the vegetative elements as a function of location on the map by using each resolution cell as a unique location thereon. In certain preferred embodiments, a single frequency is used with a linear array antenna.

  19. Nuclear material safeguards and security system analysis based on measurement

    International Nuclear Information System (INIS)

    Ign Djoko Irianto

    2007-01-01

    Nuclear material safeguards and security are the important aspect in the nuclear facility management due to the nuclear material could be terrorisms object. The two aspect of nuclear material security are nuclear material safeguards system and physical protection system. The most important in safeguards system is how to report the existence of nuclear material and the quantity of nuclear material. To perform the safeguards system the data of nuclear material are needed. The data of quality and quantity of nuclear material could be found by destructive analysis (DA) technique and non destructive analysis (NDA) technique. The DA technique are used to analysis the nuclear material that forming in powder, the NDA technique are used to analysis the nuclear material in spent fuel. In BATAN, the technique of measurement of nuclear material weight is more dominant than the other technique to be used in nuclear material safeguards and security systems. (author)

  20. Non-Contact Conductivity Measurement for Automated Sample Processing Systems

    Science.gov (United States)

    Beegle, Luther W.; Kirby, James P.

    2012-01-01

    A new method has been developed for monitoring and control of automated sample processing and preparation especially focusing on desalting of samples before analytical analysis (described in more detail in Automated Desalting Apparatus, (NPO-45428), NASA Tech Briefs, Vol. 34, No. 8 (August 2010), page 44). The use of non-contact conductivity probes, one at the inlet and one at the outlet of the solid phase sample preparation media, allows monitoring of the process, and acts as a trigger for the start of the next step in the sequence (see figure). At each step of the muti-step process, the system is flushed with low-conductivity water, which sets the system back to an overall low-conductivity state. This measurement then triggers the next stage of sample processing protocols, and greatly minimizes use of consumables. In the case of amino acid sample preparation for desalting, the conductivity measurement will define three key conditions for the sample preparation process. First, when the system is neutralized (low conductivity, by washing with excess de-ionized water); second, when the system is acidified, by washing with a strong acid (high conductivity); and third, when the system is at a basic condition of high pH (high conductivity). Taken together, this non-contact conductivity measurement for monitoring sample preparation will not only facilitate automation of the sample preparation and processing, but will also act as a way to optimize the operational time and use of consumables

  1. Design, characterization and optimization of various β γ measurement systems

    International Nuclear Information System (INIS)

    Schroettner, T.

    2010-01-01

    This thesis is based on four peer reviewed publications and reflects the scientific work from 2002 to 2009. These four papers correspond to four main chapters of the thesis. The common sense of the work is the focus on physics and electronics of measurement systems for ionizing radiation. The common aim is to increase measurement performance and sensitivity by increasing the signal to noise ratio (SNR). This has been realized by reduction of the terrestrial and cosmic radiation background and by minimizing of electromagnetic interference (EMI) and noise pick up by electronic measures. Another method, applied to increase the SNR, utilized adaptive integration time to optimize the ratio of recorded signal and background counts. For spectroscopic systems, also the stability of the energy calibration plays a key role for high SNR, as the detection limit depends on the energy resolution and stability of energy calibration. The first paper 'Optimization of an active anti cosmic veto shielding' (Schroettner at al., 2004) deals with optimization of a low level gamma spectroscopy system. Time spectroscopy of the cosmic muons passing the guard detector and the related background signals in the high purity germanium (HPGe) detector has been applied to optimize the veto time window. The fluctuation of the muon flux has been investigated and the possible induced drop and variation of measurement efficiency have been calculated and minimized. To extend the operation of the active veto towards lower γ-energies, the electronic noise and interference has been reduced by systematic location and elimination of the sources. A totally isolated power net employs filtering and regeneration of the power line for the laboratory. The second paper 'Enhancing sensitivity of portal monitoring at varying transit speed' (Schroettner at al., 2009) contains a characterization of a plastic scintillation based portal monitoring system and presents a method to increase the sensitivity of the system

  2. Performance Measurement of Management System Standards Using the Balanced Scorecard

    Directory of Open Access Journals (Sweden)

    Jan Kopia

    2017-11-01

    Full Text Available Management system standards (MSS, such as ISO standards, TQM, etc. are widely-used standards adopted by millions of organizations worldwide. It is still an unclear question whether these standards are beneficial for an organization, besides the fact that they might be required or expected by law or customers. The question, whether MSS increase the efficiency, the output, or the performance of an organization is still discussed in scientific research. One reason might be that performance measurement itself is not fully understood or in constant development ranging from pure financial evaluations over intellectual capital rating to calculating of levels of environmental, social or economic expectations known as the Trible Bottom Line. The Balanced Scorecard is one possible solution for performance measurement on a strategic and operational level and therefore useful for the measurement of the influence of MSS within organizations. This study summarized current research in the field of performance measurement in the context of MSS and IMS and the use of BSC and quantitatively and qualitatively tests the usefulness of BSC in measuring the effect of MSSs using the Execution Premium. It was found that BSC is often used, that an average number of companies integrate their measurement initiatives of their MSSs into the BSC-process, and that a high integration of MSS into the BSC improves the organizational performance. This research is useful for researchers and practitioners in order to understand the benefits of the usage of the BSC in the context of MSS or Integrated Management Systems.

  3. Statistical analysis of complex systems with nonclassical invariant measures

    KAUST Repository

    Fratalocchi, Andrea

    2011-02-28

    I investigate the problem of finding a statistical description of a complex many-body system whose invariant measure cannot be constructed stemming from classical thermodynamics ensembles. By taking solitons as a reference system and by employing a general formalism based on the Ablowitz-Kaup-Newell-Segur scheme, I demonstrate how to build an invariant measure and, within a one-dimensional phase space, how to develop a suitable thermodynamics. A detailed example is provided with a universal model of wave propagation, with reference to a transparent potential sustaining gray solitons. The system shows a rich thermodynamic scenario, with a free-energy landscape supporting phase transitions and controllable emergent properties. I finally discuss the origin of such behavior, trying to identify common denominators in the area of complex dynamics.

  4. Use of Commericially Available Software in an Attribute Measurement System

    International Nuclear Information System (INIS)

    MacArthur, Duncan W.; Bracken, David S.; Carrillo, Louis A.; Elmont, Timothy H.; Frame, Katherine C.; Hirsch, Karen L.

    2005-01-01

    A major issue in international safeguards of nuclear materials is the ability to verify that processes and materials in nuclear facilities are consistent with declaration without revealing sensitive information. An attribute measurement system (AMS) is a non-destructive assay (NDA) system that utilizes an information barrier to protect potentially sensitive information about the measurement item. A key component is the software utilized for operator interface, data collection, analysis, and attribute determination, as well as the operating system under which they are implemented. Historically, custom software has been used almost exclusively in transparency applications, and it is unavoidable that some amount of custom software is needed. The focus of this paper is to explore the extent to which commercially available software may be used and the relative merits.

  5. Optimization of the German integrated information and measurement system (IMIS)

    International Nuclear Information System (INIS)

    Wirth, E.; Weiss, W.

    2002-01-01

    The Chernobyl accident led to a widespread contamination of the environment in most European countries. In Germany, like in all other countries, it took some time to evaluate the radiological situation, time which is extremely valuable in the early phases of an accident when decisions on countermeasures like sheltering, iodine prophylaxis or evacuation have to be taken. For a better emergency preparedness the Integrated Information and Measurement System (IMIS) has been developed and established in Germany. In case of a widespread contamination of the environment, the system will provide the decision makers with all information necessary to evaluate the radiological situation and to decide on countermeasures. Presently this system is upgraded due to the adoption of the European decision supporting system RODOS and by the improvement of the national information exchange. For this purpose the web based information system ELAN has been developed. The national systems have to be integrated into the European and international communication systems. In this presentation the IMIS system is briefly described and the new features and modules of the system are discussed in greater detail

  6. Development of 3D Image Measurement System and Stereo-matching Method, and Its Archeological Measurement

    Science.gov (United States)

    Kochi, Nobuo; Ito, Tadayuki; Kitamura, Kazuo; Kaneko, Syun'ichi

    The three dimensional measurement & modeling system with digital cameras on PC is now making progress and its need and hope is increasingly felt in terrestrial (close-range) photogrammetry for such sectors as cultural heritage preservation, architecture, civil engineering, manufacturing, measurement etc. Therefore, we have developed a system to improve the accuracy of stereo-matching, which is the very core of 3D measurement. As for stereo-matching method, in order to minimize the mismatching and to be robust in geometric distortions, occlusion, as well as brightness change, we invented Coarse-to-Fine Strategy Method by integrating OCM (Orientation Code Matching) with LSM (Least Squares Matching). Thus this system could attain the accuracy of 0.26mm, when we experimented on a mannequin. And when we actually experimented on the archeological ruins in Greece and Turkey, the accuracy was within the range of 1cm, compared with their blue-print plan. Besides, formally workers used to take at least 1.5 month for this kind of survey operation with the existing method, but now workers need only 3 or 4 days. Thus, its practicality and efficiency was confirmed. This paper demonstrates our new system of 3D measurement and stereo-matching with some concrete examples as its practical application.

  7. The Recommendations for Linear Measurement Techniques on the Measurements of Nonlinear System Parameters of a Joint.

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Scott A [Univ. of Maryland Baltimore County (UMBC), Baltimore, MD (United States); Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Catalfamo, Simone [Univ. of Stuttgart (Germany); Brake, Matthew R. W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rice Univ., Houston, TX (United States); Schwingshackl, Christoph W. [Imperial College, London (United Kingdom); Reusb, Pascal [Daimler AG, Stuttgart (Germany)

    2017-01-01

    In the study of the dynamics of nonlinear systems, experimental measurements often convolute the response of the nonlinearity of interest and the effects of the experimental setup. To reduce the influence of the experimental setup on the deduction of the parameters of the nonlinearity, the response of a mechanical joint is investigated under various experimental setups. These experiments first focus on quantifying how support structures and measurement techniques affect the natural frequency and damping of a linear system. The results indicate that support structures created from bungees have negligible influence on the system in terms of frequency and damping ratio variations. The study then focuses on the effects of the excitation technique on the response for a linear system. The findings suggest that thinner stingers should not be used, because under the high force requirements the stinger bending modes are excited adding unwanted torsional coupling. The optimal configuration for testing the linear system is then applied to a nonlinear system in order to assess the robustness of the test configuration. Finally, recommendations are made for conducting experiments on nonlinear systems using conventional/linear testing techniques.

  8. Investigation of human body potential measured by a non-contact measuring system.

    Science.gov (United States)

    Ichikawa, Norimitsu

    2016-12-07

    A human body is occasionally electrified in a room. This charged object will be a source of electrostatic accidents, including the malfunction of electronic equipment. Hence, prevention of these accidents is required. Accidents occasionally occur, even though antistatic clothes and shoes are used. One of the causes for these accidents is that there is a lack of the preventive measures. This situation occurs when using, for example, unconductive wax. In this study, human body potential (voltage) is measured using a non-contact measuring system. An investigation of the human body's voltage when using this system is conducted. The result demonstrates that the voltage of a human body wearing antistatic clothes and shoes or light clothes and slippers exceeds a malfunctioning voltage of a microelectronics device when the body walks on floors. Thus, accidents may occur even if a human body wearing the antistatic clothes walks on flooring. These results will be useful in estimating determination whether electrostatic accidents occur or not.

  9. KMS fusion system resource accounting and performance measurement system for RSX11M V3. 2

    Energy Technology Data Exchange (ETDEWEB)

    Downward, J. G.

    1980-01-01

    Version 3.2 of the KMS FUSION accounting system is aimed at providing the user of RSX11M V3.2 with a versatile tool for measuring the performance of the operating system, tuning the system, and providing sufficient usage statistics so that the system manager can implement chargeback accounting if it is required by the installation. Sufficient hooks are provided so that the intrepid user can expand the system substantially beyond what is currently provided.

  10. a New Method for Measuring Macroparticulate Systems Applied to Measuring Syneresis of Renneted Milk Gels.

    Science.gov (United States)

    Maynes, Jonathan R.

    Syneresis is an integral part of cheese manufacture. The rate and extent of syneresis affect the properties of cheese. There are many factors that affect syneresis, but measured results vary because of inaccuracies in measuring techniques. To better control syneresis, an accurate mathematical description must be developed. Current mathematical models describing syneresis are limited because of inherent error in measuring techniques used to develop them. Developing an accurate model requires an accurate way to measure syneresis. The curd becomes a particle in a whey suspension when the coagulum is cut. The most effective technique to measure particle size, without interference, is with light. Approximations to rigorous Maxwellian theory render useable results for a variety of particle sizes. Assumptions of Fraunhofer diffraction theory relate absorption to the cross sectional area of a particle that is much larger than the wavelength of light being used. By applying diffraction theory to the curd-whey system, this researcher designed a new apparatus to permit measurement of large particle systems. The apparatus was tested, and calibrated, with polyacrylic beads. Then the syneresis of curd was measured with this apparatus. The apparatus was designed to measure particles in suspension. Until some syneresis takes place, curd does not satisfy this condition. Theoretical assumptions require a monolayer of scattering centers. The sample container must be thin enough to preclude stacking of the particles. This presents a unique problem with curd. If the coagulum is cut in the sample cell, it adheres to the front and back surfaces and does not synerese. The curd must be coagulated and cut externally and transferred to the sample cell with a large amount of whey. This measurement technique has other limitations that may be overcome with commercially available accessories.

  11. Assessing the Accuracy of Eyelid Measurements Utilizing the Volk Eye Check System and Clinical Measurements.

    Science.gov (United States)

    Sinha, Kunal R; Yeganeh, Amir; Goldberg, Robert A; Rootman, Daniel B

    2017-08-23

    The purpose of this study was to validate the accuracy of marginal reflex distance 1 (MRD1) measurements obtained by the Volk Eye Check system, a modified smartphone that measures MRD1 automatically, relative to clinical and digital measurements. In this prospective observational study of adults with normal eyelids and ptosis, MRD1 was measured clinically, digitally, and automatically with the Volk device. Eyes were divided into successful versus unsuccessful Volk trial groups; successful eyes were then subdivided into control and ptosis subgroups. The primary outcome measures were mean MRD1 obtained by the 3 modalities. Secondary outcome measures included the success rate of the device and the prevalence of ptosis within the successful and unsuccessful groups. In the overall sample of 88 eyes, clinical and digital MRD1 were not significantly different. Among eyes with successful Volk trials, significant differences in MRD1 measured by the 3 modalities were as follows: in the successful group, Volk MRD1 (3.05 mm) was significantly (p MRD1 (2.68 mm); in the ptosis subgroup, Volk MRD1 (2.47 mm) was significantly higher than clinical (2.05 mm; p MRD1 (1.91 mm; p MRD1 (mean difference, 1.21 mm; p MRD1 well in normal patients but overestimates MRD1 in patients with ptosis. It may be most appropriate in assessing patients with normal or elevated eyelid position. Clinical and digital MRD1 measurements were not different than each other.

  12. Analysis of neutron flux measurement systems using statistical functions

    International Nuclear Information System (INIS)

    Pontes, Eduardo Winston

    1997-01-01

    This work develops an integrated analysis for neutron flux measurement systems using the concepts of cumulants and spectra. Its major contribution is the generalization of Campbell's theorem in the form of spectra in the frequency domain, and its application to the analysis of neutron flux measurement systems. Campbell's theorem, in its generalized form, constitutes an important tool, not only to find the nth-order frequency spectra of the radiation detector, but also in the system analysis. The radiation detector, an ionization chamber for neutrons, is modeled for cylindrical, plane and spherical geometries. The detector current pulses are characterized by a vector of random parameters, and the associated charges, statistical moments and frequency spectra of the resulting current are calculated. A computer program is developed for application of the proposed methodology. In order for the analysis to integrate the associated electronics, the signal processor is studied, considering analog and digital configurations. The analysis is unified by developing the concept of equivalent systems that can be used to describe the cumulants and spectra in analog or digital systems. The noise in the signal processor input stage is analysed in terms of second order spectrum. Mathematical expressions are presented for cumulants and spectra up to fourth order, for important cases of filter positioning relative to detector spectra. Unbiased conventional estimators for cumulants are used, and, to evaluate systems precision and response time, expressions are developed for their variances. Finally, some possibilities for obtaining neutron radiation flux as a function of cumulants are discussed. In summary, this work proposes some analysis tools which make possible important decisions in the design of better neutron flux measurement systems. (author)

  13. An Air Bearing Rotating Coil Magnetic Measurement System

    CERN Document Server

    Gottschalk, Stephen C; Taylor, David J; Thayer, William

    2005-01-01

    This paper describes a rotating coil magnetic measurement system supported on air bearings. The design is optimized for measurements of 0.1micron magnetic centerline changes on long, small aperture quadrupoles. Graphite impregnated epoxy resin is used for the coil holder and coil winding forms. Coil holder diameter is 11 mm with a length between supports of 750mm. A pair of coils is used to permit quadrupole bucking during centerline measurements. Coil length is 616mm, inner radius 1.82mm, outer radius 4.74mm. The key features of the mechanical system are simplicity; air bearings for accurate, repeatable measurements without needing warm up time and a vibration isolated stand that uses a steel-topped Newport optical table with air suspension. Coil rotation is achieved by a low noise servo motor controlled by a standalone Ethernet servo board running custom servo software. Coil calibration procedures that correct wire placement errors, tests for mechanical resonances, and other system checks will also be discu...

  14. A novel scanning system using an industrial robot and the workspace measurement and positioning system

    Science.gov (United States)

    Zhao, Ziyue; Zhu, Jigui; Yang, Linghui; Lin, Jiarui

    2015-10-01

    The present scanning system consists of an industrial robot and a line-structured laser sensor which uses the industrial robot as a position instrument to guarantee the accuracy. However, the absolute accuracy of an industrial robot is relatively poor compared with the good repeatability in the manufacturing industry. This paper proposes a novel method using the workspace measurement and positioning system (wMPS) to remedy the lack of accuracy of the industrial robot. In order to guarantee the positioning accuracy of the system, the wMPS which is a laser-based measurement technology designed for large-volume metrology applications is brought in. Benefitting from the wMPS, this system can measure different cell-areas by the line-structured laser sensor and fuse the measurement data of different cell-areas by using the wMPS accurately. The system calibration which is the procedure to acquire and optimize the structure parameters of the scanning system is also stated in detail in this paper. In order to verify the feasibility of the system for scanning the large free-form surface, an experiment is designed to scan the internal surface of the door of a car-body in white. The final results show that the measurement data of the whole measuring areas have been jointed perfectly and there is no mismatch in the figure especially in the hole measuring areas. This experiment has verified the rationality of the system scheme, the correctness and effectiveness of the relevant methods.

  15. Novel System for Continuous Measurements of Dissolved Gases in Liquids

    Science.gov (United States)

    Baer, D. S.; Liem, J.; Owano, T. G.; Gupta, M.

    2014-12-01

    Measurements of dissolved gases in lakes, rivers and oceans may be used to quantify underwater greenhouse gas generation, air-surface exchange, and pollution migration. Studies involving quantification of dissolved gases typically require obtaining water samples (from streams, lakes, or ocean water) and transporting them to a laboratory, where they are degased. The gases obtained are then generally measured using gas chromatography and isotope ratio mass spectrometry for concentrations and isotope ratios, respectively. This conventional, off-line, discrete-sample methodology is time consuming and labor intensive, and thus severely inhibits detailed spatial and temporal mapping of dissolved gases. In this work, we describe the commercial development of a new portable membrane-based gas extraction system (18.75" x 18.88" x 10.69", 16 kg, 85 watts) that interfaces directly to our cavity enhanced laser absorption based (or Off-Axis ICOS) gas analyzers to continuously and quickly measure concentrations and isotope ratios of dissolved gases. By accurately controlling the water flow rate through the membrane contactor, gas pressure on the outside and water pressure on the inside of the membrane, the system can generate precise and highly reproducible results. Furthermore, the gas-phase mole fractions (parts per million, ppm) may be converted into dissolved gas concentrations (nM), by accurately measuring the gas flow rates in and out of the extraction system. We will present detailed laboratory test data that quantifies the performance (linearity, precision, and dynamic range) of the system for measurements of the concentrations and isotope ratios of dissolved greenhouse gases (methane, carbon dioxide, and nitrous oxide) continuously and in real time.

  16. Vision and dual IMU integrated attitude measurement system

    Science.gov (United States)

    Guo, Xiaoting; Sun, Changku; Wang, Peng; Lu, Huang

    2018-01-01

    To determination relative attitude between two space objects on a rocking base, an integrated system based on vision and dual IMU (inertial determination unit) is built up. The determination system fuses the attitude information of vision with the angular determinations of dual IMU by extended Kalman filter (EKF) to obtain the relative attitude. One IMU (master) is attached to the measured motion object and the other (slave) to the rocking base. As the determination output of inertial sensor is relative to inertial frame, thus angular rate of the master IMU includes not only motion of the measured object relative to inertial frame but also the rocking base relative to inertial frame, where the latter can be seen as redundant harmful movement information for relative attitude determination between the measured object and the rocking base. The slave IMU here assists to remove the motion information of rocking base relative to inertial frame from the master IMU. The proposed integrated attitude determination system is tested on practical experimental platform. And experiment results with superior precision and reliability show the feasibility and effectiveness of the proposed attitude determination system.

  17. Technological measures of protection in the copyright system

    Directory of Open Access Journals (Sweden)

    Radovanović Sanja

    2011-01-01

    Full Text Available Digital exploitation of works often exceed the limit to which the holder can control the exploitation of their intellectual creations, and the protection provided by legal norms are, in the era of a fast exchange of information, may prove to be insufficiently effective. For these reasons, the rights holders are increasingly opting for preventive care through placement of physical obstacles to the exploitation of copyright works, generic called technological protection measures (known as digital right management (DRM. Simultaneously with the development of the application of these measures flows the process of finding ways to circumvent them. Therefore, the effectiveness of technological measures depends on exactly the question of their legal protection, which now exists in most of modern legal systems. However, in the normative solutions there are differences, which reflect the problems in finding adequate forms of protection. They mostly stem from the fact that the sanctioning of circumvention (or preparatory actions of technological measures put into the question the purpose of copyright protection in general. Hence, in this paper we tried to point out the normative solutions accepted in modern legal systems and practical implications of what they have. Conclusion that arises is that the legal shaping of technological measures is not completed and that further technological developments open new dilemmas.

  18. Biomagnetic Measurement System on Mice-Evaluation of System Performance by MCG and Application to MEG

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, T [Department of electrical engineering and bioscience, Waseda University, 3-4-1 Ohkubo, Shinjuku-ku, Tokyo 169-8555 (Japan); Shirai, K [Department of electrical engineering and bioscience, Waseda University, 3-4-1 Ohkubo, Shinjuku-ku, Tokyo 169-8555 (Japan); Ono, Y [Department of electrical engineering and bioscience, Waseda University, 3-4-1 Ohkubo, Shinjuku-ku, Tokyo 169-8555 (Japan); Kasai, N [National Institute of Advanced Industrial Science and Technology, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8568 (Japan); Odawara, A [SII Nano Technology Inc. 1-8 Nakase, Mihama-ku, Chiba 261-8507 (Japan); Ishiyama, A [Department of electrical engineering and bioscience, Waseda University, 3-4-1 Ohkubo, Shinjuku-ku, Tokyo 169-8555 (Japan)

    2006-06-01

    We developed a biomagnetic measurement system on mice. Our initial model of the system has the magnetic field sensitivity of 1.3 pT/Hz{sup 1/2} in the white-noise region (10 Hz-10 kHz). And using the system, we succeeded to obtain magnetically the heart activity on mice. However, in its application to measure the brain activity on mice, it was necessary to improve the magnetic field sensitivity of the system. Therefore, we changed the material of the window cap, which holds a sapphire glass window on the dewar tail, to ceramic. The system noise was decreased and the magnetic field sensitivity of the system was improved to 0.75 pT/Hz{sup 1/2} in the white-noise region. For an initial measurement of the brain activity, we also developed a whisker stimulation system using a piezoelectric element to evoke somatosensory responses.

  19. Optical fiber sensors measurement system and special fibers improvement

    Science.gov (United States)

    Jelinek, Michal; Hrabina, Jan; Hola, Miroslava; Hucl, Vaclav; Cizek, Martin; Rerucha, Simon; Lazar, Josef; Mikel, Bretislav

    2017-06-01

    We present method for the improvement of the measurement accuracy in the optical frequency spectra measurements based on tunable optical filters. The optical filter was used during the design and realization of the measurement system for the inspection of the fiber Bragg gratings. The system incorporates a reference block for the compensation of environmental influences, an interferometric verification subsystem and a PC - based control software implemented in LabView. The preliminary experimental verification of the measurement principle and the measurement system functionality were carried out on a testing rig with a specially prepared concrete console in the UJV Řež. The presented system is the laboratory version of the special nuclear power plant containment shape deformation measurement system which was installed in the power plant Temelin during last year. On the base of this research we started with preparation other optical fiber sensors to nuclear power plants measurement. These sensors will be based on the microstructured and polarization maintaining optical fibers. We started with development of new methods and techniques of the splicing and shaping optical fibers. We are able to made optical tapers from ultra-short called adiabatic with length around 400 um up to long tapers with length up to 6 millimeters. We developed new techniques of splicing standard Single Mode (SM) and Multimode (MM) optical fibers and splicing of optical fibers with different diameters in the wavelength range from 532 to 1550 nm. Together with development these techniques we prepared other techniques to splicing and shaping special optical fibers like as Polarization-Maintaining (PM) or hollow core Photonic Crystal Fiber (PCF) and theirs cross splicing methods with focus to minimalize backreflection and attenuation. The splicing special optical fibers especially PCF fibers with standard telecommunication and other SM fibers can be done by our developed techniques. Adjustment

  20. Integrated measure and control system for textile machinery

    Science.gov (United States)

    Liu, Yuantao; Zhao, Jinzhi; Zhao, Zexiang

    2010-12-01

    In this paper, textile mechanical drive control is researched. Textile machinery integrated measure and control system is established. The system is composed of micro-computer, PLC, transducer, implement device, all kinds of detective components and industrial Ethernet etc. Technology of industrial field bus control and Internet technique are applied. The system is on a background of textile production technique, such as spring, woven, chemical fiber, non-woven, dyeing and finishing. A network based open integrated control system is developed. Various characteristics of production technique flow and textile machinery movement discipline are presented. Configuration software is introduced according to user's control tasks. Final remote automatic controls are finished. This may make development cost reduced, and development periods shortened. Some problems in textile machinery development process are solved, which may make transparency factory and remote development realized.

  1. Mapping system, magnetic measurement and shimming in CRM cyclotron

    International Nuclear Information System (INIS)

    Zhong Junqing; Lv Yinlong; Yin Zhiguo

    2008-01-01

    The Central Region Model (CRM) is a compact H - cyclotron. Because of the intrinsic asymmetry of the magnet, its machining and assembly are very complicated. To guarantee the magnet field distribution, it is necessary to measure and shim the magnetic field. This paper presents a study on the design and use of the mapping system based on the Hall Effect and the re-machining of shimming bars after analyzing the magnetic field measurement data to achieve the isochronous field and good vertical focusing frequency. The method to effectively reduce the amplitude of the 1st harmonic by shimming bars 1s also introduced. (authors)

  2. Dielectric properties measurement system at cryogenic temperatures and microwave frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Molla, J.; Ibarra, A.; Margineda, J.; Zamarro, J. M.; Hernandez, A.

    1994-07-01

    A system based on the resonant cavity method has been developed to measure the permittivity and loss tangent at 12-18 GHz over the temperature range 80 K to 300 K. Changes of permittivity as low as 0.01 % in the range 1 to 30, and 3 x 10{sup 6} for loss tangent values below 10{sup 2}, can be obtained without requiring temperature stability. The thermal expansion coefficient and resistivity factor of copper have been measured between 80 K and 300 K. Permittivity of sapphire and loss tangent of alumina of 99.9 % purity in the same temperature range are presented. (Author) 23 refs.

  3. Mobile system for on-road measurements of air pollutants

    Science.gov (United States)

    Katulski, Ryszard J.; Namieśnik, Jacek; Sadowski, Jarosław; Stefański, Jacek; Szymańska, Krystyna; Wardencki, Waldemar

    2010-04-01

    The paper presents a prototype of a mobile monitoring system for measuring the levels of the main traffic air pollutants (C6H6, NO2, NOx, CO, and CO2,) in cities. The novelty of the proposed system lies in the fact that it can be utilized to monitor emissions from urban traffic along roads and areas where traditional monitoring stations cannot be placed. In the proposed system, the monitoring device can be mounted on any moving vehicle (such as a car, bus, or truck) rather than be attached to a dedicated van, as most systems of this kind found in literature are. Analyzers used in this system are small portable structures that contain an electronic instrument to measure, record, and transmit relevant data on concentrations of the pollutants to a website. The model outcome for carbon monoxide obtained in functional tests in real conditions is also presented here. Data on temporal changes of carbon monoxide concentration are compared against meteorological parameters and speed of the vehicle. Spatial interpolation techniques are applied to obtain a nonplanar visualization of carbon monoxide and benzene concentrations in the main arteries of a city.

  4. A magnetic suspension system for measuring liquid density

    Directory of Open Access Journals (Sweden)

    Luz María Centeno González

    2013-01-01

    Full Text Available Density is a derived quantity of mass and length; it is defined as mass per volume unit and its SI unit is kg/m3. National metrology institutes have been designing and building their own magnetic suspension systems during the last 5 decades for making fluid density measurements; this has allowed them to carry out research into liquids and gases’ physical characteristics. This paper was aimed at designing and developing a magnetic suspension system for a magnetic balance used in determining liquid density to be used in CENAM’s metrology density laboratories.

  5. Indoor Inter-Robot Distance Measurement in Collaborative Systems

    Directory of Open Access Journals (Sweden)

    FILOTE, C.

    2010-08-01

    Full Text Available This paper focuses on the problem of autonomous distance calculation between multiple mobile robots in collaborative systems. We propose and discuss two distinct methods, specifically developed under important design and functional constraints, such as the speed of operation, accuracy, energy and cost efficiency. Moreover, the methods are designed to be applied to indoor robotic systems and are independent of fixed landmarks. The measurement results, performed on the CORE-TX case study, show that the proposed solutions meet the design requirements previously specified.

  6. Colors of Outer Solar System Objects Measured with VATT

    Science.gov (United States)

    Romanishin, William; Tegler, S. C.; Consolmagno, G. J.

    2010-10-01

    Over the past 7 years, we have measured optical B-V and V-R colors for about 40 minor outer solar system objects using the 1.8-m Vatican Advanced Technology Telescope (VATT) located on Mt. Graham in southeast Arizona. We will present these colors and use them to update the discussion of colors of minor bodies in the outer solar system. We gratefully acknowledge funding from the NASA Planetary Astronomy Program to Northern Arizona University and the U. of Oklahoma which helped support this work.

  7. Design of mass flow rate measurement system for SST-1 superconducting magnet system

    International Nuclear Information System (INIS)

    Varmora, P.; Sharma, A.N.; Khristi, Y.; Prasad, U.; Patel, D.; Doshi, K.; Pradhan, S.

    2016-01-01

    Highlights: • Design of Venturi meter for SST-1 magnet system. • Details of Helium mass flow measurement system used in SST-1. • Instruments and measurement techniques for flow measurement. • VME based data acquisition system details and flow calculation and results from SST-1 campaigns. - Abstract: Superconducting Magnet System (SCMS) of Steady State Superconducting Tokamak – 1 (SST-1) is forced-flow cooled by a closed cycle 1.3 kW (at 4.5 K) class Helium Refrigerator cum Liquefier (HRL) system. An accurate measurement of helium mass flow rate in different coils is required to ensure the uniform cooling of the cold mass in the entire range of operating temperature (300 K to 4.5 K) and pressure (0.9–0.4 MPa). To meet this requirement, indigenously designed and fabricated venturi meters are installed on 27 different coils of SST-1 SCMS. A VME based Data Acquisition System (DAS) has been developed and used to acquire the flow measurement data from different flowmeters. The details of the design of venturi meter, its different measurement and signal conditioning components, the data acquisition system and the mass flow rate calculation method are described in this paper. The mass flow rate measurement data from cryogenic acceptance and SST-1 magnet commissioning experiments are also presented and discussed in this paper.

  8. Research on cloud-based remote measurement and analysis system

    Science.gov (United States)

    Gao, Zhiqiang; He, Lingsong; Su, Wei; Wang, Can; Zhang, Changfan

    2015-02-01

    The promising potential of cloud computing and its convergence with technologies such as cloud storage, cloud push, mobile computing allows for creation and delivery of newer type of cloud service. Combined with the thought of cloud computing, this paper presents a cloud-based remote measurement and analysis system. This system mainly consists of three parts: signal acquisition client, web server deployed on the cloud service, and remote client. This system is a special website developed using asp.net and Flex RIA technology, which solves the selective contradiction between two monitoring modes, B/S and C/S. This platform supplies customer condition monitoring and data analysis service by Internet, which was deployed on the cloud server. Signal acquisition device is responsible for data (sensor data, audio, video, etc.) collection and pushes the monitoring data to the cloud storage database regularly. Data acquisition equipment in this system is only conditioned with the function of data collection and network function such as smartphone and smart sensor. This system's scale can adjust dynamically according to the amount of applications and users, so it won't cause waste of resources. As a representative case study, we developed a prototype system based on Ali cloud service using the rotor test rig as the research object. Experimental results demonstrate that the proposed system architecture is feasible.

  9. Relating Standardized Visual Perception Measures to Simulator Visual System Performance

    Science.gov (United States)

    Kaiser, Mary K.; Sweet, Barbara T.

    2013-01-01

    Human vision is quantified through the use of standardized clinical vision measurements. These measurements typically include visual acuity (near and far), contrast sensitivity, color vision, stereopsis (a.k.a. stereo acuity), and visual field periphery. Simulator visual system performance is specified in terms such as brightness, contrast, color depth, color gamut, gamma, resolution, and field-of-view. How do these simulator performance characteristics relate to the perceptual experience of the pilot in the simulator? In this paper, visual acuity and contrast sensitivity will be related to simulator visual system resolution, contrast, and dynamic range; similarly, color vision will be related to color depth/color gamut. Finally, we will consider how some characteristics of human vision not typically included in current clinical assessments could be used to better inform simulator requirements (e.g., relating dynamic characteristics of human vision to update rate and other temporal display characteristics).

  10. Computer Simulation of Angle-measuring System of Photoelectric Theodolite

    International Nuclear Information System (INIS)

    Zeng, L; Zhao, Z W; Song, S L; Wang, L T

    2006-01-01

    In this paper, a virtual test platform based on malfunction phenomena is designed, using the methods of computer simulation and numerical mask. It is used in the simulation training of angle-measuring system of photoelectric theodolite. Actual application proves that this platform supplies good condition for technicians making deep simulation training and presents a useful approach for the establishment of other large equipment simulation platforms

  11. The Libera as a PS orbit measurement system building block

    CERN Document Server

    Belleman, J M; CERN. Geneva. AB Department

    2005-01-01

    During the year 2004, extensive tests using a Libera data processor have been made in order to study its suitability as a building block for a complete PS trajectory and orbit measurement system. The Libera consists of four fast 12-bits ADCs, a Virtex II Pro FPGA and a large memory. This note presents some of the results of the analysis of acquisitions made on a position pick-up in the CERN PS.

  12. Rapid density-measurement system with vibrating-tube densimeter

    International Nuclear Information System (INIS)

    Kayukawa, Yohei; Hasumoto, Masaya; Watanabe, Koichi

    2003-01-01

    Concerning an increasing demand for environmentally friendly refrigerants including hydrocarbons, thermodynamic properties of such new refrigerants, especially densities, are essential information for refrigeration engineering. A rapid density-measurement system with vibrating-tube densimeter was developed in the present study with an aim to supply large numbers of high-quality PVT property data in a short period. The present system needs only a few minutes to obtain a single datum, and requires less than 20 cm 3 sample fluid. PVT properties in the entire fluid-phase, vapor-pressures, saturated-liquid densities for pure fluid are available. Liquid densities, bubble-point pressures and saturated-liquid densities for mixture can be obtained. The measurement range is from 240 to 380 K for temperature and up to 7 MPa for pressure. By employing a new calibration function, density can be precisely obtained even at lower densities. The densimeter is calibrated with pure water and iso-octane which is one of the density-standard fluids, and then measurement uncertainty was evaluated to be 0.1 kg m -3 or 0.024% whichever greater in density, 0.26 kPa or 0.022% whichever greater in pressure and 3 mK for temperature, respectively. The performance of the present measurement system was examined by measuring thermodynamic properties for refrigerant R134a. The experimental results were compared with available equation of state and confirmed to agree with it within ±0.05% for liquid densities while ±0.5% in pressure for the gas phase

  13. Symbolic analysis of spatio-temporal systems: The measurement problem

    International Nuclear Information System (INIS)

    Brown, R.; Tang, Xianzhu; Tracy, E.R.

    1996-01-01

    We consider the problem of measuring physical quantities using time-series observations. The approach taken is to validate theoretical models which are derived heuristically or from first principles. The fitting of parameters in such models constitutes the measurement. This is a basic problem in measurement science and a wide array of tools are available. However, an important gap in the present toolkit exists when the system of interest, and hence the models used, exhibit chaotic or turbulent behavior. The development of reliable schemes for analyzing such signals is necessary before one can claim to have a quantitative understanding of the underlying physics. In experimental situations, the number of independently measured time-series is limited, but the number of dynamical degrees of freedom can be large. In addition, the signals of interest will typically be embedded in a noisy background. In the symbol statistics approach, the time-series is coarse-grained and converted into a long, symbol stream. The probability of occurrence of various symbol sequences of fixed length constitutes the symbol statistics. These statistics contain a wealth of information about the underlying dynamics and, as we shall discuss, can be used to validate models. Previously, we have applied this symbolic approach to low dimensional systems with great success. The symbol statistics are robust up to noise/signal ∼20%. At higher noise levels the symbol statistics are biased, but in a relatively simple manner. By including the noise characteristics into the model, we were able to use the symbol statistics to measure parameters even when signal/noise is ∼ O(1). More recently, we have extended the symbolic approach to spatio-temporal systems. We have considered both coupled-map lattices and the complex Ginzburg-Landau equation. This equation arises generically near the onset of instabilities

  14. Measurement System Analyses - Gauge Repeatability and Reproducibility Methods

    Science.gov (United States)

    Cepova, Lenka; Kovacikova, Andrea; Cep, Robert; Klaput, Pavel; Mizera, Ondrej

    2018-02-01

    The submitted article focuses on a detailed explanation of the average and range method (Automotive Industry Action Group, Measurement System Analysis approach) and of the honest Gauge Repeatability and Reproducibility method (Evaluating the Measurement Process approach). The measured data (thickness of plastic parts) were evaluated by both methods and their results were compared on the basis of numerical evaluation. Both methods were additionally compared and their advantages and disadvantages were discussed. One difference between both methods is the calculation of variation components. The AIAG method calculates the variation components based on standard deviation (then a sum of variation components does not give 100 %) and the honest GRR study calculates the variation components based on variance, where the sum of all variation components (part to part variation, EV & AV) gives the total variation of 100 %. Acceptance of both methods among the professional society, future use, and acceptance by manufacturing industry were also discussed. Nowadays, the AIAG is the leading method in the industry.

  15. Digital measurement system for the LHC klystron high voltage modulator.

    CERN Document Server

    Mikkelsen, Anders

    Accelerating voltage in the Large Hadron Collider (LHC) is created by a means of 16 superconducting standing wave RF cavities, each fed by a 400MHz/300kW continuous wave klystron amplifier. Part of the upgrade program for the LHC long shutdown one is to replace the obsolete analogue current and voltage measurement circuitry located in the high voltage bunkers by a new, digital system, using ADCs and optical fibres. A digital measurement card is implemented and integrated into the current HV modulator oil tank (floating at -58kV) and interfaced to the existing digital VME boards collecting the data for several klystrons at the ground potential. Measured signals are stored for the logging, diagnostics and post-mortem analysis purposes.

  16. Novel ultrasonic distance measuring system based on correlation method

    Directory of Open Access Journals (Sweden)

    Gądek K.

    2014-09-01

    Full Text Available This paper presents an innovative method for measuring the time delay of ultrasonic waves. Pulse methods used in the previous studies was characterized by latency. The method of phase correlation, presented in this article is free from this disadvantages. Due to the phase encoding with the use of Walsh functions the presented method allows to obtain better precision than previous methods. The algorithm to measure delay of the reflected wave with the use of microprocessor ARM Cortex M4 linked to a PC has been worked out and tested. This method uses the signal from the ultrasonic probe to precisely determine the time delay, caused by the propagation in medium, possible. In order to verify the effectiveness of the method a part of the measuring system was implemented in LabVIEW. The presented method proved to be effective, as it is shown in presented simulation results

  17. The design and implementation of the AVNG measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Macarthur, Duncan W [Los Alamos National Laboratory; Thron, Jonathan [Los Alamos National Laboratory; Razinkov, Sergey [RFNC-VNIIEF; Livke, Alexander [RFNC-VNIIEF; Kondratov, Sergey [RFNC-VNIIEF

    2010-01-01

    An attribute measurement system (AMS) measures a number of unclassified attributes of potentially classified material. By displaying these unclassified results only as red or green lights, the AMS protects potentially classified information while still generating confidence in the measurement result. The AVNG that we describe is an AMS built by RFNC-VNIIEF in Sarov, Russia. The AVNG detects neutron and gamma radiation signatures and displays the three unclassified attributes of 'plutonium presence,' 'plutonium mass >2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) < 0.1.' In this presentation, we will describe the design of the AVNG neutron and gamma detector subsystems, as well as the design of the entire AMS incorporating these detectors. We will also describe the construction of the AVNG and the final design that was demonstrated in June 2009.

  18. On the Number of Mather Measures of Lagrangian Systems

    Science.gov (United States)

    Bernard, Patrick

    2010-09-01

    In 1996, Ricardo Ricardo Mañé discovered that Mather measures are in fact the minimizers of a “universal” infinite dimensional linear programming problem. This fundamental result has many applications, of which one of the most important is to the estimates of the generic number of Mather measures. Mañé obtained the first estimation of that sort by using finite dimensional approximations. Recently, we were able, with Gonzalo Contreras, to use this method of finite dimensional approximation in order to solve a conjecture of John Mather concerning the generic number of Mather measures for families of Lagrangian systems. In the present paper we obtain finer results in that direction by applying directly some classical tools of convex analysis to the infinite dimensional problem. We use a notion of countably rectifiable sets of finite codimension in Banach (and Frechet) spaces which may deserve independent interest.

  19. A beam energy measurement system at NIRS-930 cyclotron

    International Nuclear Information System (INIS)

    Hojo, S.; Honma, T.; Sakamoto, Y.; Miyahara, N.; Okada, T.; Komatsu, K.; Tsuji, N.; Yamada, S.

    2005-01-01

    A beam energy measurement system employing a set of capacitive probes has been developed at NIRS-930 cyclotron. Principle of the measurement is applying a modified-TOF method, so that the two proves are installed at one of the straight section in the beam transport line. Usually they are separated about 5.8 m, which is equivalent to the almost final path length of the beam extracted in the cyclotron. In the measurement, two beam signals are superimposed by adjusting a position of the downstream-probe along the beam direction with watching an oscilloscope screen roughly. In order to determine the beam energy accurately the signals are processed by MCA with suitable electric module. (author)

  20. An upgraded interferometer-polarimeter system for broadband fluctuation measurements

    International Nuclear Information System (INIS)

    Parke, E.; Ding, W. X.; Brower, D. L.; Duff, J.

    2016-01-01

    Measuring high-frequency fluctuations (above tearing mode frequencies) is important for diagnosing instabilities and transport phenomena. The Madison Symmetric Torus interferometer-polarimeter system has been upgraded to utilize improved planar-diode mixer technology. The new mixers reduce phase noise and allow more sensitive measurements of fluctuations at high frequency. Typical polarimeter rms phase noise values of 0.05°–0.07° are obtained with 400 kHz bandwidth. The low phase noise enables the resolution of fluctuations up to 250 kHz for polarimetry and 600 kHz for interferometry. The importance of probe beam alignment for polarimetry is also verified; previously reported tolerances of ≤0.1 mm displacement for equilibrium and tearing mode measurements minimize contamination due to spatial misalignment to within acceptable levels for chords near the magnetic axis.

  1. An upgraded interferometer-polarimeter system for broadband fluctuation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Parke, E., E-mail: eparke@ucla.edu; Ding, W. X.; Brower, D. L. [Department of Physics and Astronomy, University of California Los Angeles, Los Angeles, California 90095 (United States); Duff, J. [Department of Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States)

    2016-11-15

    Measuring high-frequency fluctuations (above tearing mode frequencies) is important for diagnosing instabilities and transport phenomena. The Madison Symmetric Torus interferometer-polarimeter system has been upgraded to utilize improved planar-diode mixer technology. The new mixers reduce phase noise and allow more sensitive measurements of fluctuations at high frequency. Typical polarimeter rms phase noise values of 0.05°–0.07° are obtained with 400 kHz bandwidth. The low phase noise enables the resolution of fluctuations up to 250 kHz for polarimetry and 600 kHz for interferometry. The importance of probe beam alignment for polarimetry is also verified; previously reported tolerances of ≤0.1 mm displacement for equilibrium and tearing mode measurements minimize contamination due to spatial misalignment to within acceptable levels for chords near the magnetic axis.

  2. An electron density measurement using an analyzer based imaging system

    International Nuclear Information System (INIS)

    Bewer, Brian

    2011-01-01

    Using a monochromatic X-ray beam from a synchrotron source the electron density of a homogeneous target was determined by measuring the refraction that occurs at the air-target interface for a known angle of incidence. The angle of deviation that these X-rays undergo at the transition between materials is micro-radian to submicro-radian in scale. Existing analyzer based imaging systems are designed to measure submicro-radian angle changes and commonly use monochromatic hard X-ray beams generated from synchrotron sources. A preliminary experiment using the analyzer based imaging apparatus at the Canadian Light Source Biomedical Imaging and Therapy beamline and a half cylinder shaped plastic target will be presented. By measuring the angle of deviation of the photon beam at several discrete angular positions of the target the electron density of the target material was determined.

  3. Measuring the systemic risk in the South African banking sector

    Directory of Open Access Journals (Sweden)

    Gregory M. Foggitt

    2017-10-01

    Full Text Available Background: In the aftermath of the sub-prime crisis, systemic risk has become a greater priority for regulators, with the National Treasury (2011 stating that regulators should proactively monitor changes in systemic risk. Aim: The aim is to quantify systemic risk as the capital shortfall an institution is likely to experience, conditional to the entire financial sector being undercapitalised. Setting: We measure the systemic risk index (SRISK of the South African (SA banking sector between 2001 and 2013. Methods: Systemic risk is measured with the SRISK. Results: Although the results indicated only moderate systemic risk in the SA financial sector over this period, there were significant spikes in the levels of systemic risk during periods of financial turmoil in other countries. Especially the stock market crash in 2002 and the subprime crisis in 2008. Based on our results, the largest contributor to systemic risk during quiet periods was Investec, the bank in our sample which had the lowest market capitalisation. However, during periods of financial turmoil, the contributions of other larger banks increased markedly. Conclusion: The implication of these spikes is that systemic risk levels may also be highly dependent on external economic factors, in addition to internal banking characteristics. The results indicate that the economic fundamentals of SA itself seem to have little effect on the amount of systemic risk present in the financial sector. A more significant relationship seems to exist with the stability of the financial sectors in foreign countries. The implication therefore is that complying with individual banking regulations, such as Basel, and corporate governance regulations promoting ethical behaviour, such as King III, may not be adequate. It is therefore proposed that banks should always have sufficient capital reserves in order to mitigate the effects of a financial crisis in a foreign country. The use of worst

  4. An automatic multichannel generalized system for frequency measurement

    Directory of Open Access Journals (Sweden)

    Gomah G.

    2015-01-01

    Full Text Available Monitoring the performance of the primary frequency sources continuously through comparing it versus the transfer standards and the calibration of the secondary frequency sources periodically versus the primary ones are of the main missions assigned to any time and frequency laboratory either it was a calibration laboratory or a national metrological laboratory. An automatic Generalized System (GS for monitoring/calibrating any frequency source that has a Relative Frequency Offset (RFO greater than 1 × 10-14Hz/Hz has been built. This GS is able to use either of two measurement methods according to the accuracy of the frequency source being measured. A graphical programming language, which is Labview, was used in writing the software required for both hardware control and data logging. So, the software can be easily reconfigured for any upgrading plans. Also a flexible arrangement for the hardware setup was used such that two measurement systems are merged in one system. So, according to the user needs the right hardware setup can be chosen. The results obtained by this GS were verified through comparing them to those generated by one of the commercial turnkey solutions.

  5. Biochemical oxygen demand measurement by mediator method in flow system.

    Science.gov (United States)

    Liu, Ling; Bai, Lu; Yu, Dengbin; Zhai, Junfeng; Dong, Shaojun

    2015-06-01

    Using mediator as electron acceptor for biochemical oxygen demand (BOD) measurement was developed in the last decade (BODMed). However, until now, no BOD(Med) in a flow system has been reported. This work for the first time describes a flow system of BOD(Med) method (BOD(Med)-FS) by using potassium ferricyanide as mediator and carbon fiber felt as substrate material for microbial immobilization. The system can determine the BOD value within 30 min and possesses a wider analytical linear range for measuring glucose-glutamic acid (GGA) standard solution from 2 up to 200 mg L(-1) without the need of dilution. The analytical performance of the BOD(Med)-FS is comparable or better than that of the previously reported BOD(Med) method, especially its superior long-term stability up to 2 months under continuous operation. Moreover, the BOD(Med)-FS has same determination accuracy with the conventional BOD5 method by measuring real samples from a local wastewater treatment plant (WWTP). Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Advanced wavefront measurement and analysis of laser system modeling

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, C.R.; Auerback, J.M. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    High spatial resolution measurements of the reflected or transmitted wavefronts of large aperture optical components used in high peak power laser systems is now possible. These measurements are produced by phase shifting interferometry. The wavefront data is in the form of 3-D phase maps that reconstruct the wavefront shape. The emphasis of this work is on the characterization of wavefront features in the mid-spatial wavelength range (from 0.1 to 10.0 mm) and has been accomplished for the first time. Wavefront structure from optical components with spatial wavelengths in this range are of concern because their effects in high peak power laser systems. At high peak power, this phase modulation can convert to large magnitude intensity modulation by non-linear processes. This can lead to optical damage. We have developed software to input the measured phase map data into beam propagation codes in order to model this conversion process. We are analyzing this data to: (1) Characterize the wavefront structure produced by current optical components, (2) Refine our understanding of laser system performance, (3) Develop a database from which future optical component specifications can be derived.

  7. GPS water level measurements for Indonesia's Tsunami Early Warning System

    Directory of Open Access Journals (Sweden)

    T. Schöne

    2011-03-01

    Full Text Available On Boxing Day 2004, a severe tsunami was generated by a strong earthquake in Northern Sumatra causing a large number of casualties. At this time, neither an offshore buoy network was in place to measure tsunami waves, nor a system to disseminate tsunami warnings to local governmental entities. Since then, buoys have been developed by Indonesia and Germany, complemented by NOAA's Deep-ocean Assessment and Reporting of Tsunamis (DART buoys, and have been moored offshore Sumatra and Java. The suite of sensors for offshore tsunami detection in Indonesia has been advanced by adding GPS technology for water level measurements.

    The usage of GPS buoys in tsunami warning systems is a relatively new approach. The concept of the German Indonesian Tsunami Early Warning System (GITEWS (Rudloff et al., 2009 combines GPS technology and ocean bottom pressure (OBP measurements. Especially for near-field installations where the seismic noise may deteriorate the OBP data, GPS-derived sea level heights provide additional information.

    The GPS buoy technology is precise enough to detect medium to large tsunamis of amplitudes larger than 10 cm. The analysis presented here suggests that for about 68% of the time, tsunamis larger than 5 cm may be detectable.

  8. Study of accurate volume measurement system for plutonium nitrate solution

    Energy Technology Data Exchange (ETDEWEB)

    Hosoma, T. [Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan). Tokai Works

    1998-12-01

    It is important for effective safeguarding of nuclear materials to establish a technique for accurate volume measurement of plutonium nitrate solution in accountancy tank. The volume of the solution can be estimated by two differential pressures between three dip-tubes, in which the air is purged by an compressor. One of the differential pressure corresponds to the density of the solution, and another corresponds to the surface level of the solution in the tank. The measurement of the differential pressure contains many uncertain errors, such as precision of pressure transducer, fluctuation of back-pressure, generation of bubbles at the front of the dip-tubes, non-uniformity of temperature and density of the solution, pressure drop in the dip-tube, and so on. The various excess pressures at the volume measurement are discussed and corrected by a reasonable method. High precision-differential pressure measurement system is developed with a quartz oscillation type transducer which converts a differential pressure to a digital signal. The developed system is used for inspection by the government and IAEA. (M. Suetake)

  9. System for improving measurement accuracy of transducer by measuring transducer temperature and resistance change using thermoelectric voltages

    Science.gov (United States)

    Anderson, Karl F. (Inventor); Parker, Allen R., Jr. (Inventor)

    1993-01-01

    A constant current loop measuring system measures a property including the temperature of a sensor responsive to an external condition being measured. The measuring system includes thermocouple conductors connected to the sensor, sensing first and second induced voltages responsive to the external condition. In addition, the measuring system includes a current generator and reverser generating a constant current, and supplying the constant current to the thermocouple conductors in forward and reverse directions generating first and second measured voltages, and a determining unit receiving the first and second measured voltages from the current generator and reverser, and determining the temperature of the sensor responsive to the first and second measured voltages.

  10. Research on the processing technology of medium-caliber aspheric lens in the optoelectronic integrated test system

    Science.gov (United States)

    Liu, Dan; Yu, Xin-ying; Wang, Wei

    2016-10-01

    In the optoelectronic integrated test system, surface profile and finish of the optical element are put forward higher request. Taking an aspherical quartz glass lens with a diameter of 200mm as example, taking Preston hypothesis as the theoretical basis, analyze the influence of surface quality of various process parameters, including the workpiece and the tool axis spindle speed, wheel type, concentration polishing, polishing mold species, dwell time, polishing pressure and other parameters. Using CNC method for the surface profile and surface quality of the lens were investigated. Taking profilometer measurement results as a guide, by testing and simulation analysis, process parameters were improved constantly in the process of manufacturing. Mid and high frequency error were trimmed and improved so that the surface form gradually converged to the required accuracy. The experimental results show that the final accuracy of the surface is less than 2µm and the surface finish is, which fulfils the accuracy requirement of aspherical focusing lens in optical system.

  11. Principles of design of measuring channels of data acquisition systems for charged particle accelerator control systems

    International Nuclear Information System (INIS)

    Arsen'ev, V.A.; Bondarenko, I.M.; Gerasimov, V.P.

    1981-01-01

    Principle of design of measuring channels (MC) of data- measuring systems of charged particle accelerators are presented. The MC comprises a monitor and a measuring converter. Enumerated are some measuring modules in the KAMAK standard permitting to realize the MC on the base of relay three-wire multiplexers and integrating analog-to-digital converters (ADC) with swimming inlet, the by-discharge balancing ADC the ADC of the type of time to pulse converter, the integrating type ADC, semiconducting analog multiplexer, relay analog multiplexer, memory device. Examples of realization of data acquisition systems on accelerators are presented. Shown is the block- diagram of the measuring system of the orbit position and betatron oscillations of IHEP booster permitting to provide accuracy of measuring beam center of gravity within 0.5 mm range. A brief description of the measuring system of spatial characteristics of the beam of the Erevan electron synchrotron is presented. The system provides measuring the dimensions of the beam with the error not more than 1% and current density of the beam in the consequent coordinates of the cross section with the error not more than 2% [ru

  12. Study on USB Based CAN Bus for Data Measurement System

    Science.gov (United States)

    Wu, Weibin; Hong, Tiansheng; Zhu, Yuqing; He, Guangbin; Ye, Cheng; Li, Haobiao; Chen, Chuwen

    Control area network (CAN) is an international protocol of field bus and universal serial bus (USB) is developing more and more widely. On the other hand, the USB technology combined with the CAN application is still in the development stage, so this research has broad prospects. The USB-based CAN bus system hardware consists of a CAN module, a USB communication module and a micro controller. It has been designed for real-time display and can save the CAN bus message. In addition it has been debugged in actual measurement accompanied by the Kvaser USB CAN II. The test results show that the system can correctly receive all messages frame from Kvaser CanKing. Finally the system has been applied to the project of citrus orchard for transmission of data of the citrus and tree parameters.

  13. "Calibration" system for spectral measurements and its experimental results

    Science.gov (United States)

    Bruchkouskaya, Sviatlana I.; Katkovsky, Leonid V.; Belyaev, Boris I.; Malyshev, Vladislav B.

    2017-04-01

    "Calibration" system has been developed at A. N. Sevchenko Research Institute of Applied Physical Problems of the Belarusian State University. It was designed for measuring the characteristics of spectral reflectance of all types of natural surfaces (test sites) in ground conditions or on board of aircraft carriers and has the following components: - Photospectroradiometr (PhSR) of high resolution with a range of 400-900 nm, equipped with a digital time-lapse video system; - Two-channel modular spectroradiometer (TMS) with a range of 400-900 nm, designed for simultaneous measurements of reflected light brightness of the underlying surface and the incident radiation from the upper hemisphere; - Two portable spectroradiometers (PSR-700 and PSR-1300) with a spectral range 800-1500 nm; 1200-2500 nm; - Scanning solar spectropolarimeter (SSP-600) with a range of 350-950 nm for measurements of direct sunlight and scattered by the atmosphere at different angles; "Calibration" system provides spectral resolution of 5.2 nm in a range of 400-900 nm, 10 nm in a range of 800-1500 nm and 15 nm in a range of 1200-2500 nm. Measurements of the optical characteristics of solar radiation (for determining parameters of the atmosphere) and that of underlying surface are synchronous. There is also a set of special nozzles for measurements of spectral brightness coefficients, polarization characteristics and spectral albedo. Spectra and images are geotagged to the navigation data (time, GPS). For the measurements of spectral reflection dependencies within "Monitoring-SG" framework expeditions to the Kuril Islands, Kursk aerospace test site and Kamchatka Peninsula were conducted in 2015 and 2016. The spectra of different underlying surfaces have been obtained: soils, plants and water objects, sedimentary and volcanic rocks. These surveys are a valuable material for further researches and selection of test facilities for flight calibration of space imaging systems. Information obtained

  14. Force measuring optical tweezers system for long time measurements of P pili stability

    Science.gov (United States)

    Andersson, Magnus; Fällman, Erik; Uhlin, Bernt Eric; Axner, Ove

    2006-02-01

    A force-measuring optical tweezers instrumentation and long time measurements of the elongation and retraction of bacterial fimbriae from Uropathogenic E. coli (UPEC) under strain are presented. The instrumentation is presented in some detail. Special emphasis is given to measures taken to reduce the influence of noise and drifts in the system and from the surrounding, which makes long term force measurements possible. Individual P pili from UPEC bacteria were used as a biological model system for repetitive unfolding and refolding cycles of bacterial fimbriae under equilibrium conditions. P pili have evolved into a three-dimensional helix-like structure, the PapA rod, that can be successively and significantly elongated and/or unfolded when exposed to external forces. The instrumentation is used for characterization of the force-vs.-elongation response of the PapA rod of individual P pili, with emphasis on the long time stability of the forced unfolding and refolding of the helical structure of the PapA rod. The results show that the PapA rod is capable of withstanding extensive strain, leading to a complete unfolding of the helical structure, repetitive times during the life cycle of a bacterium without any noticeable alteration of the mechanical properties of the P pili. This function is believed to be importance for UPEC bacteria in vivo since it provides a close contact to a host cell (which is an initial step of invasion) despite urine cleaning attempts.

  15. Application of plutonium inventory measurement system (PIMS) and temporary canister verification system (TCVS) at RRP

    International Nuclear Information System (INIS)

    Noguchi, Yoshihiko; Nakamura, Hironobu; Adachi, Hideto; Iwamoto, Tomonori

    2004-01-01

    In U-Pu co-denitration area at Rokkasho Reprocessing Plant (RRP), Plutonium Inventory Measurement System (PIMS) and Temporary Canister Verification System (TCVS) are installed to provide efficient and effective safeguards. PIMS measures Pu quantity inside pipes and vessels installed in glove boxes by total neutron counting method. PIMS consists of total 142 neutron detector attached on the wall and top of glove boxes and neutron count rates of each detectors are related to each other to calculate Pu quantity of each process areas. In this moment, inactive calibration using Cf-source was completed. On the other hand, TCVS measures Pu quantity of canisters inside temporary storage by coincidence counting method and it will be installed before the active test. These systems have monitoring function as additional measures. This paper describes specification, performance and measurement principles of PIMS and TCVS. (author)

  16. 26 CFR 801.1 - Balanced performance measurement system; in general.

    Science.gov (United States)

    2010-04-01

    ...: Customer Satisfaction Measures; Employee Satisfaction Measures; and Business Results Measures. The IRS is likewise required to establish a performance evaluation system for individual employees. (b) [Reserved] [T... (CONTINUED) INTERNAL REVENUE PRACTICE BALANCED SYSTEM FOR MEASURING ORGANIZATIONAL AND EMPLOYEE PERFORMANCE...

  17. Urban air quality measurements using a sensor-based system

    Science.gov (United States)

    Ródenas, Mila; Hernández, Daniel; Gómez, Tatiana; López, Ramón; Muñoz, Amalia

    2017-04-01

    Air pollution levels in urban areas have increased the interest, not only of the scientific community but also of the general public, and both at the regional and at the European level. This interest has run in parallel to the development of miniaturized sensors, which only since very recently are suitable for air quality measurements. Certainly, their small size and price allows them to be used as a network of sensors capable of providing high temporal and spatial frequency measurements to characterize an area or city and with increasing potential, under certain considerations, as a complement of conventional methods. Within the frame of the LIFE PHOTOCITYTEX project (use of photocatalytic textiles to help reducing air pollution), CEAM has developed a system to measure gaseous compounds of importance for urban air quality characterization. This system, which allows an autonomous power supply, uses commercial NO, NO2, O3 and CO2 small sensors and incorporates measurements of temperature and humidity. A first version, using XBee boards (Radiofrequency) for communications has been installed in the urban locations defined by the project (tunnel and school), permitting the long-term air quality characterization of sites in the presence of the textiles. An improved second version of the system which also comprises a sensor for measuring particles and which uses GPRS for communications, has been developed and successfully installed in the city center of Valencia. Data are sent to a central server where they can be accessed by citizens in nearly real time and online and, in general, they can be utilized in the air quality characterization, for decision-making related to decontamination (traffic regulation, photocatalytic materials, etc.), in air quality models or in mobile applications of interest for the citizens. Within this work, temporal trends obtained with this system in different urban locations will be shown, discussing the impact of the characteristics of the

  18. Magnetic field measuring system for remapping the ORIC magnetic field

    International Nuclear Information System (INIS)

    Mosko, S.W.; Hudson, E.D.; Lord, R.S.; Hensley, D.C.; Biggerstaff, J.A.

    1977-01-01

    The Holifield Heavy Ion Research Facility will integrate a new 25 MV tandem electrostatic acccelerator into the existing cyclotron laboratory which includes the Oak Ridge Isochronous Cyclotron (ORIC). Computations of ion paths for beam injection from the new tandem into ORIC require field mapping in the regions traversed by the beam. Additional field data is also desired for the higher levels (approx.19 kG) now used for most heavy ion beams. The magnetic field measurement system uses 39 flip coil/current integrator sets with computer controlled data scanning. The coils are spaced radially at 1 inch intervals in an arm which can be rotated azimuthally in 2 degree increments. The entire flip coil assembly can be shifted to larger radii to measure fields beyond the pole boundary. Temperature stabilization of electronic circuitry permits a measurement resolution of +-1 gauss over a dynamic range of +-25,000 gauss. The system will process a scan of 8000 points in about one hour

  19. Measuring impact crater depth throughout the solar system

    Science.gov (United States)

    Robbins, Stuart J.; Watters, Wesley A.; Chappelow, John E.; Bray, Veronica J.; Daubar, Ingrid J.; Craddock, Robert A.; Beyer, Ross A.; Landis, Margaret E.; Ostrach, Lillian; Tornabene, Livio L.; Riggs, Jamie D.; Weaver, Brian P.

    2018-01-01

    One important, almost ubiquitous, tool for understanding the surfaces of solid bodies throughout the solar system is the study of impact craters. While measuring a distribution of crater diameters and locations is an important tool for a wide variety of studies, so too is measuring a crater's “depth.” Depth can inform numerous studies including the strength of a surface and modification rates in the local environment. There is, however, no standard data set, definition, or technique to perform this data‐gathering task, and the abundance of different definitions of “depth” and methods for estimating that quantity can lead to misunderstandings in and of the literature. In this review, we describe a wide variety of data sets and methods to analyze those data sets that have been, are currently, or could be used to derive different types of crater depth measurements. We also recommend certain nomenclature in doing so to help standardize practice in the field. We present a review section of all crater depths that have been published on different solar system bodies which shows how the field has evolved through time and how some common assumptions might not be wholly accurate. We conclude with several recommendations for researchers which could help different data sets to be more easily understood and compared.

  20. The impact of mammographic imaging systems on density measurement

    Science.gov (United States)

    Damases, Christine N.; Brennan, Patrick C.; McEntee, Mark F.

    2015-03-01

    The purpose of this study is to investigate whether having a mammogram on differing manufacturer equipment will affect a woman's breast density (BD) measurement. The data set comprised of 40 cases, each containing a combined image of the left craniocaudal (LCC) and left mediolateral oblique (LMLO). These images were obtained from 20 women age between 42-89 years. The images were acquired on two imaging systems (GE and Hologic) one year apart. Volumetric BD was assessed by using Volpara Density Grade (VDG) and average BD% (AvBD%). Twenty American Board of Radiology (ABR) examiners assessed the same images using the BIRADS BD scale 1-4. Statistical comparisons were performed on the means using Mann-Whitney, on correlation using Spearman's rank coefficient of correlation and agreement using Cohen's Kappa. The absolute median BIRADS difference between GE and Hologic was 0.225 (2.00 versus 2.00; pHologic (2.00 versus 2.00; pHologic systems showed no difference (6.51 versus 6.79; pHologic systems showed strong positive correlation (ρ=0.904; pHologic systems for BIRADS density shown with Cohen's Kappa (κ=0.692; p<0.001), however the systems demonstrated an almost perfect agreement for VDG (κ=0.933; p<0.001).

  1. U. S. Department of Energy Aerial Measuring Systems

    Energy Technology Data Exchange (ETDEWEB)

    J. J. Lease

    1998-10-01

    The Aerial Measuring Systems (AMS) is an aerial surveillance system. This system consists of remote sensing equipment to include radiation detectors; multispectral, thermal, radar, and laser scanners; precision cameras; and electronic imaging and still video systems. This equipment, in varying combinations, is mounted in an airplane or helicopter and flown at different heights in specific patterns to gather various types of data. This system is a key element in the US Department of Energy's (DOE) national emergency response assets. The mission of the AMS program is twofold--first, to respond to emergencies involving radioactive materials by conducting aerial surveys to rapidly track and map the contamination that may exist over a large ground area and second, to conduct routinely scheduled, aerial surveys for environmental monitoring and compliance purposes through the use of credible science and technology. The AMS program evolved from an early program, begun by a predecessor to the DOE--the Atomic Energy Commission--to map the radiation that may have existed within and around the terrestrial environments of DOE facilities, which produced, used, or stored radioactive materials.

  2. Overview of the aerial radiological measuring system (ARMS) program

    International Nuclear Information System (INIS)

    Deal, L.J.; Doyle, J.F. III.

    1975-01-01

    Since 1960 EG and G, Inc. has developed and maintained for the U.S. Energy Research and Development Administration (ERDA) a state-of-the-art radiation surveillance program called the Aerial Radiological Measuring System (ARMS). Radiological surveys covering more than 300,000 square miles have been performed. In addition to the radiation detector gear, the system includes an inertial navigation system, radar altimeter, meteorological probes, air sampler, air sample analyzer, multispectral cameras, aerial mapping camera and infrared scanner. The recently improved data acquisition system, REDAR, records all inputs digitally on magnetic tape and is readily mounted in fixed-wing aircraft or helicopters. The data analysis system, REDAC, is mounted in a mobile processing laboratory which accompanies the aircraft on surveys. Radiation isopleth maps, both for gross counts and selected isotopes, can be prepared in the field. Special computer software enables the ARMS to detect changes of less than 1.0 μR/hr in exposure rates between successive surveys of a given site

  3. U. S. Department of Energy Aerial Measuring Systems

    International Nuclear Information System (INIS)

    Lease, J.J.

    1998-01-01

    The Aerial Measuring Systems (AMS) is an aerial surveillance system. This system consists of remote sensing equipment to include radiation detectors; multispectral, thermal, radar, and laser scanners; precision cameras; and electronic imaging and still video systems. This equipment, in varying combinations, is mounted in an airplane or helicopter and flown at different heights in specific patterns to gather various types of data. This system is a key element in the US Department of Energy's (DOE) national emergency response assets. The mission of the AMS program is twofold--first, to respond to emergencies involving radioactive materials by conducting aerial surveys to rapidly track and map the contamination that may exist over a large ground area and second, to conduct routinely scheduled, aerial surveys for environmental monitoring and compliance purposes through the use of credible science and technology. The AMS program evolved from an early program, begun by a predecessor to the DOE--the Atomic Energy Commission--to map the radiation that may have existed within and around the terrestrial environments of DOE facilities, which produced, used, or stored radioactive materials

  4. Perform Thermodynamics Measurements on Fuel Cycle Case Study Systems

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Leigh R. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-09-01

    This document was prepared to meet FCR&D level 3 milestone M3FT-14IN0304022, “Perform Thermodynamics Measurements on Fuel Cycle Case Study Systems.” This work was carried out under the auspices of the Thermodynamics and Kinetics FCR&D work package. This document reports preliminary work in support of determining the thermodynamic parameters for the ALSEP process. The ALSEP process is a mixed extractant system comprised of a cation exchanger 2-ethylhexyl-phosphonic acid mono-2-ethylhexyl ester (HEH[EHP]) and a neutral solvating extractant N,N,N’,N’-tetraoctyldiglycolamide (TODGA). The extractant combination produces complex organic phase chemistry that is challenging for traditional measurement techniques. To neutralize the complexity, temperature dependent solvent extraction experiments were conducted with neat TODGA and scaled down concentrations of the ALSEP formulation to determine the enthalpies of extraction for the two conditions. A full set of thermodynamic data for Eu, Am, and Cm extraction by TODGA from 3.0 M HNO3 is reported. These data are compared to previous extraction results from a 1.0 M HNO3 aqueous medium, and a short discussion of the mixed HEH[EHP]/TODGA system results is offered.

  5. A portable measuring system for a competitive binding glucose biosensor

    Science.gov (United States)

    Colvin, Lydia E.; Means, A. Kristen; Grunlan, Melissa A.; Coté, Gerard L.

    2018-02-01

    Central to minimizing the long- and short-term complications associated with diabetes is careful monitoring and maintenance of blood glucose at normal levels. Towards replacing conventionally used finger-prick glucose testing, indwelling continuous glucose monitors (CGMs) based on amperometric electrodes have been introduced to the market. Envisioned to lead to a CGM with an increased lifetime, we report herein a fluorescently-labeled competitive binding assay contained within a hydrogel membrane whose glucose response is measured via a novel portable system. The optical system design included a laser source, bifurcated fiber, laser filter and simple fiber coupled spectrometer to obtain the change in FRET pair ratio of the assay. Glucose response of the assay in free solution was measured using this system across the physiologic range (0-200 mg/dL). The FRET pair ratio signal was seen to increase with glucose and the standard error of calibration was 22.42 mg/dL with a MARD value of 14.85%. When the assay was contained within the hydrogel membrane's central cavity and similarly analyzed, the standard error increased but the assay maintained its reversibility.

  6. Comparison Testings between Two High-temperature Strain Measurement Systems

    Science.gov (United States)

    Lei, J.-F.; Castelli, M. G.; Androjna, D.; Blue, C.; Blue, R.; Lin, R. Y.

    1996-01-01

    An experimental evaluation was conducted at NASA Lewis Research Center to compare and contrast the performance of a newly developed resistance strain gage, the PdCr temperature-compensated wire strain gage, to that of a conventional high-temperature extensometry. The evaluation of the two strain measurement systems was conducted through the application of various thermal and mechanical loading spectra using a high-temperature thermomechanical uniaxial testing system equipped with quartz lamp heating. The purpose of the testing was not only to compare and contrast the two strain sensors but also to investigate the applicability of the PdCr strain gage to the testing environment typically employed when characterizing the high-temperature mechanical behavior of structural materials. Strain measurement capabilities to 8OO C were investigated with a nickel base superalloy IN100 substrate material, and application to titanium matrix composite (TMC) materials was examined with the SCS-6/Ti-15-3 08 system. PdCr strain gages installed by three attachment techniques, namely, flame spraying, spot welding and rapid infrared joining were investigated.

  7. Streamflow Measurement Using A Riversonde Uhf Radar System

    Science.gov (United States)

    Teague, C.; Barrick, D.; Lilleboe, P.; Cheng, R.

    Initial field tests have been performed to evaluate the performance of a RiverSonde streamflow measurement system. The tests were conducted at a concrete-lined canal and a natural river in central California during June, 2000. The RiverSonde is a UHF radar operating near 350 MHz and is based on a modified SeaSonde system normally used to measure ocean surface currents in salt water using lower frequencies (5­25 MHz). The RiverSonde uses energy scattered by Bragg-resonant 0.5 m water waves and does not require any sensors in the water. Water velocity is calculated by observing the Doppler shift of the scattered radar energy and comparing that with the Doppler shift expected from resonant waves in still water. The radar has sufficient resolution to allow the estimation of a velocity profile across the width of the river. The antennas consisted of a 2-element transmitting antenna and a 3-element receiving antenna. The transmitting antenna provided broad illumination of the water surface, and MUSIC direction finding was used to determine the arrival direction of the re- flected radar energy. The transmitting and receiving antennas were placed on opposite banks to reduce the signal intensity variation across the channel. A chirp frequency sweep was used to determine range. Transmitted power was under 1 W, and the max- imum range was a few hundred meters. Range resolution was on the order of 10 m, and velocity resolution was about 2.5 cm/s. Extensive in-situ surface truth measurements were performed by personnel from the United States Geological Survey. The instruments included current meters suspended at various depths from a small boat positioned at several locations across the channel, video tracking of many floaters (tennis balls) on the water surface, an optical flow meter, and anemometer wind measurements. Typical water velocities were about 40 cm/s, and RMS velocity differences between the radar and in-situ measurements were 6­18% of the mean flow, with similar

  8. Accurate measurement of RF exposure from emerging wireless communication systems

    International Nuclear Information System (INIS)

    Letertre, Thierry; Toffano, Zeno; Monebhurrun, Vikass

    2013-01-01

    Isotropic broadband probes or spectrum analyzers (SAs) may be used for the measurement of rapidly varying electromagnetic fields generated by emerging wireless communication systems. In this paper this problematic is investigated by comparing the responses measured by two different isotropic broadband probes typically used to perform electric field (E-field) evaluations. The broadband probes are submitted to signals with variable duty cycles (DC) and crest factors (CF) either with or without Orthogonal Frequency Division Multiplexing (OFDM) modulation but with the same root-mean-square (RMS) power. The two probes do not provide accurate enough results for deterministic signals such as Worldwide Interoperability for Microwave Access (WIMAX) or Long Term Evolution (LTE) as well as for non-deterministic signals such as Wireless Fidelity (WiFi). The legacy measurement protocols should be adapted to cope for the emerging wireless communication technologies based on the OFDM modulation scheme. This is not easily achieved except when the statistics of the RF emission are well known. In this case the measurement errors are shown to be systematic and a correction factor or calibration can be applied to obtain a good approximation of the total RMS power.

  9. Implementation of Moderator Circulation Test Temperature Measurement System

    International Nuclear Information System (INIS)

    Lim, Yeong Muk; Hong, Seok Boong; Kim, Min Seok; Choi, Hwa Rim; Kim, Hyung Shin

    2016-01-01

    Moderator Circulation Test(MCT) facility is 1/4 scale facility designed to reproduce the important characteristics of moderator circulation in a CANDU6 calandria under a range of operating conditions. MCT is an equipment with 380 acrylic pipes instead of the heater rods and a preliminary measurement of velocity field using PIV(Particle Image Velocimetry) is performed under the iso-thermal test conditions. The Korea Atomic Energy Research Institute (KAERI) started implementation of MCT Temperature Measurement System (TMS) using multiple infrared sensors. To control multiple infrared sensors, MCT TMS is implemented using National Instruments (NI) LabVIEW programming language. The MCT TMS is implemented to measure sensor data of multiple infrared sensors using the LabVIEW. The 35 sensor pipes of MCT TMS are divided into 2 ports to meet the minimum measurement time of 0.2 seconds. The software of MCT TMS is designed using collection function and processing function. The MCT TMS has the function of monitoring the states of multiple infrared sensors. The GUI screen of MCT TMS is composed of sensor pipe categories for user

  10. Implementation of Moderator Circulation Test Temperature Measurement System

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Yeong Muk; Hong, Seok Boong; Kim, Min Seok; Choi, Hwa Rim [KAERI, Daejeon (Korea, Republic of); Kim, Hyung Shin [Chungnam University, Daejeon (Korea, Republic of)

    2016-05-15

    Moderator Circulation Test(MCT) facility is 1/4 scale facility designed to reproduce the important characteristics of moderator circulation in a CANDU6 calandria under a range of operating conditions. MCT is an equipment with 380 acrylic pipes instead of the heater rods and a preliminary measurement of velocity field using PIV(Particle Image Velocimetry) is performed under the iso-thermal test conditions. The Korea Atomic Energy Research Institute (KAERI) started implementation of MCT Temperature Measurement System (TMS) using multiple infrared sensors. To control multiple infrared sensors, MCT TMS is implemented using National Instruments (NI) LabVIEW programming language. The MCT TMS is implemented to measure sensor data of multiple infrared sensors using the LabVIEW. The 35 sensor pipes of MCT TMS are divided into 2 ports to meet the minimum measurement time of 0.2 seconds. The software of MCT TMS is designed using collection function and processing function. The MCT TMS has the function of monitoring the states of multiple infrared sensors. The GUI screen of MCT TMS is composed of sensor pipe categories for user.

  11. Upgraded bolometer system on JET for improved radiation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Huber, A. [Institut fuer Plasmaphysik, Forschungszentrum Juelich GmbH, EURATOM Association, Trilateral Euregio Cluster, D-52425 Juelich (Germany)], E-mail: A.Huber@fz-juelich.de; McCormick, K. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Andrew, P.; Beaumont, P.; Dalley, S. [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Fink, J.; Fuchs, J.C. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Fullard, K.; Fundamenski, W. [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Ingesson, L.C. [FOM-Instituut voor Plasmafysica, Nieuwegein (Netherlands); Mast, F. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Jachmich, S. [Institut fuer Plasmaphysik, Forschungszentrum Juelich GmbH, EURATOM Association, Trilateral Euregio Cluster, D-52425 Juelich (Germany); Matthews, G.F. [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Mertens, Ph.; Philipps, V. [Institut fuer Plasmaphysik, Forschungszentrum Juelich GmbH, EURATOM Association, Trilateral Euregio Cluster, D-52425 Juelich (Germany); Pitts, R.A. [CRPP, Association EURATOM-Confederation Suisse, EPFL, Lausanne (Switzerland); Sanders, S. [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Zeidner, W. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany)

    2007-10-15

    Two new main-vessel bolometric cameras (KB5) with horizontal and vertical views of the plasma cross-section have been installed on JET, providing a substantial upgrade in capabilities: more viewing chords (24 chords for each camera), higher energy range (up to 8 keV), higher sensitivity ({approx}6.2 V/W), lower noise and therefore, lower detectable signals ({approx}2 {mu}W/cm{sup 2} at a bandwidth of 200 Hz), higher temporal resolution ({approx}2 ms). In addition, three new dedicated divertor bolometer cameras (KB3) with 12 lines-of-sight in total, optimised views and technical improvements have replaced the old ones. The combination of KB3 and KB5 systems provides measurements with significantly improved spatial resolution, allowing the divertor and main chamber radiation fractions to be clearly resolved. The sensitivity measured with an in situ electrical method matches very well with that obtained using a light source calibration. The deviation between the two methods is less than 7% and is in the range of the measurement accuracy. The experimentally measured geometric functions closely match those computed using the design values of geometry. Tomographic reconstructions of high density divertor plasmas with ITER-like configuration are presented which clearly demonstrate the capability of the new diagnostic.

  12. Inexpensive Measuring System for the Characterization of Organic Transistors

    Directory of Open Access Journals (Sweden)

    Clara Pérez-Fuster

    2018-01-01

    Full Text Available A measuring module has been specifically designed for the electrical characterization of organic semiconductor devices such as organic field effect transistors (OFETs and organic electrochemical transistors (OECTs according to the IEEE 1620-2008 standard. This device has been tested with OFETs based on 6,13-bis(triisopropylsilylethinylpentacene (TIPS-pentacene. The measuring system has been constructed using a NI-PXIe-1073 chassis with integrated controller and two NI-PXI-4132 programmable high-precision source measure units (SMUs that offer a four-quadrant ± 100 V output, with resolution down to 10 pA. LabVIEW™ has been used to develop the appropriate program. Most of the main OFET parameters included in the IEEE 1620 standard can be measured by means of this device. Although nowadays expensive devices for the characterization of Si-based transistors are available, devices for the characterization of organic transistors are not yet widespread in the market. Fabrication of a specific and flexible module that can be used to characterize this type of transistors would provide a powerful tool to researchers.

  13. Microgravity Acceleration Measurement System (MAMS) Flight Configuration Verification and Status

    Science.gov (United States)

    Wagar, William

    2000-01-01

    The Microgravity Acceleration Measurement System (MAMS) is a precision spaceflight instrument designed to measure and characterize the microgravity environment existing in the US Lab Module of the International Space Station. Both vibratory and quasi-steady triaxial acceleration data are acquired and provided to an Ethernet data link. The MAMS Double Mid-Deck Locker (DMDL) EXPRESS Rack payload meets all the ISS IDD and ICD interface requirements as discussed in the paper which also presents flight configuration illustrations. The overall MAMS sensor and data acquisition performance and verification data are presented in addition to a discussion of the Command and Data Handling features implemented via the ISS, downlink and the GRC Telescience Center displays.

  14. H- beam neutralization measurements in a solenoidal beam transport system

    International Nuclear Information System (INIS)

    Sherman, J.; Pitcher, E.; Stevens, R.; Allison, P.

    1992-01-01

    H minus beam space-charge neutralization is measured for 65-mA, 35-keV beams extracted from a circular-aperture Penning surface-plasma source, the small-angle source. The H minus beam is transported to a RFQ matchpoint by a two-solenoid magnet system. Beam noise is typically ±4%. A four-grid analyzer is located in a magnetic-field-free region between the two solenoid magnets. H minus potentials are deduced from kinetic energy measurements of particles (electrons and positive ions) ejected radially from the beam channel by using a griddled energy analyzer. Background neutral gas density is increased by the introduction of additional Xe and Ar gases, enabling the H minus beam to become overneutralized

  15. Investigation of human body potential measured by a non-contact measuring system

    Science.gov (United States)

    ICHIKAWA, Norimitsu

    2016-01-01

    A human body is occasionally electrified in a room. This charged object will be a source of electrostatic accidents, including the malfunction of electronic equipment. Hence, prevention of these accidents is required. Accidents occasionally occur, even though antistatic clothes and shoes are used. One of the causes for these accidents is that there is a lack of the preventive measures. This situation occurs when using, for example, unconductive wax. In this study, human body potential (voltage) is measured using a non-contact measuring system. An investigation of the human body’s voltage when using this system is conducted. The result demonstrates that the voltage of a human body wearing antistatic clothes and shoes or light clothes and slippers exceeds a malfunctioning voltage of a microelectronics device when the body walks on floors. Thus, accidents may occur even if a human body wearing the antistatic clothes walks on flooring. These results will be useful in estimating determination whether electrostatic accidents occur or not. PMID:27319403

  16. Development of the Computerized Model of Performance-Based Measurement System to Measure Nurses' Clinical Competence.

    Science.gov (United States)

    Liou, Shwu-Ru; Liu, Hsiu-Chen; Tsai, Shu-Ling; Cheng, Ching-Yu; Yu, Wei-Chieh; Chu, Tsui-Ping

    2016-04-01

    Critical thinking skills and clinical competence are for providing quality patient care. The purpose of this study is to develop the Computerized Model of Performance-Based Measurement system based on the Clinical Reasoning Model. The system can evaluate and identify learning needs for clinical competency and be used as a learning tool to increase clinical competency by using computers. The system includes 10 high-risk, high-volume clinical case scenarios coupled with questions testing clinical reasoning, interpersonal, and technical skills. Questions were sequenced to reflect patients' changing condition and arranged by following the process of collecting and managing information, diagnosing and differentiating urgency of problems, and solving problems. The content validity and known-groups validity was established. The Kuder-Richardson Formula 20 was 0.90 and test-retest reliability was supported (r = 0.78). Nursing educators can use the system to understand students' needs for achieving clinical competence, and therefore, educational plans can be made to better prepare students and facilitate their smooth transition to a future clinical environment. Clinical nurses can use the system to evaluate their performance-based abilities and weakness in clinical reasoning. Appropriate training programs can be designed and implemented to practically promote nurses' clinical competence and quality of patient care.

  17. Predicting biological system objectives de novo from internal state measurements

    Directory of Open Access Journals (Sweden)

    Maranas Costas D

    2008-01-01

    Full Text Available Abstract Background Optimization theory has been applied to complex biological systems to interrogate network properties and develop and refine metabolic engineering strategies. For example, methods are emerging to engineer cells to optimally produce byproducts of commercial value, such as bioethanol, as well as molecular compounds for disease therapy. Flux balance analysis (FBA is an optimization framework that aids in this interrogation by generating predictions of optimal flux distributions in cellular networks. Critical features of FBA are the definition of a biologically relevant objective function (e.g., maximizing the rate of synthesis of biomass, a unit of measurement of cellular growth and the subsequent application of linear programming (LP to identify fluxes through a reaction network. Despite the success of FBA, a central remaining challenge is the definition of a network objective with biological meaning. Results We present a novel method called Biological Objective Solution Search (BOSS for the inference of an objective function of a biological system from its underlying network stoichiometry as well as experimentally-measured state variables. Specifically, BOSS identifies a system objective by defining a putative stoichiometric "objective reaction," adding this reaction to the existing set of stoichiometric constraints arising from known interactions within a network, and maximizing the putative objective reaction via LP, all the while minimizing the difference between the resultant in silico flux distribution and available experimental (e.g., isotopomer flux data. This new approach allows for discovery of objectives with previously unknown stoichiometry, thus extending the biological relevance from earlier methods. We verify our approach on the well-characterized central metabolic network of Saccharomyces cerevisiae. Conclusion We illustrate how BOSS offers insight into the functional organization of biochemical networks

  18. Evolution of an open system as a continuous measurement of this system by its environment

    International Nuclear Information System (INIS)

    Mensky, Michael B.

    2003-01-01

    The restricted-path-integral (RPI) description of a continuous quantum measurement is rederived starting from the description of an open system by the Feynman-Vernon influence functional. For this end the total evolution operator of the compound system consisting of the open system and its environment is decomposed into the sum of partial evolution operators. Accordingly, the influence functional of the open system is decomposed into the integral of partial influence functionals (PIF). If the partial evolution operators or PIF are chosen in such a way that they decohere (do not interfere with each other), then the formalism of RPI effectively arises. The evolution of the open system may then be interpreted as a continuous measurement of this system by its environment. This is possible if the environment is macroscopic or mesoscopic

  19. Development of a Neutron Spectroscopic System Utilizing Compressed Sensing Measurements

    Directory of Open Access Journals (Sweden)

    Vargas Danilo

    2016-01-01

    Full Text Available A new approach to neutron detection capable of gathering spectroscopic information has been demonstrated. The approach relies on an asymmetrical arrangement of materials, geometry, and an ability to change the orientation of the detector with respect to the neutron field. Measurements are used to unfold the energy characteristics of the neutron field using a new theoretical framework of compressed sensing. Recent theoretical results show that the number of multiplexed samples can be lower than the full number of traditional samples while providing the ability to have some super-resolution. Furthermore, the solution approach does not require a priori information or inclusion of physics models. Utilizing the MCNP code, a number of candidate detector geometries and materials were modeled. Simulations were carried out for a number of neutron energies and distributions with preselected orientations for the detector. The resulting matrix (A consists of n rows associated with orientation and m columns associated with energy and distribution where n < m. The library of known responses is used for new measurements Y (n × 1 and the solver is able to determine the system, Y = Ax where x is a sparse vector. Therefore, energy spectrum measurements are a combination of the energy distribution information of the identified elements of A. This approach allows for determination of neutron spectroscopic information using a single detector system with analog multiplexing. The analog multiplexing allows the use of a compressed sensing solution similar to approaches used in other areas of imaging. A single detector assembly provides improved flexibility and is expected to reduce uncertainty associated with current neutron spectroscopy measurement.

  20. Binary VLE measurements and modeling for selected amine systems

    OpenAIRE

    Saleem, Fahad

    2011-01-01

    During the course of this work, vapor pressure data of pure water, DEEA and DIPEA was measured. The results give good agreement with literature data. VLE data of DEEA-H2O and DIPEA-H2O systems was then obtained at varying concentration and temperature (50-95oC) range. Experimental activity coefficients were calculated using this VLE data. Moreover, FTIR spectroscopy in conjunction with ?The Unscrambler? was used for amine analyses of the experimental samples and results were compared with ...

  1. Specialized sorting and measuring system for site remediation

    International Nuclear Information System (INIS)

    Runge, H.; Christ, G.

    2001-01-01

    The machine design and measurement philosophy of the SSGE, developed for excavation and treatment of some 21,000 metric tons of ground material and concrete from NUKEM decommissioned fuel element factory, have already been passed the official licensing procedure. The start up of site clean-up is scheduled for summer 2001. With the SSGE there has been made available a method to safe and economically remediate contaminated ground of nuclear sites. The SSEG, being a mobile system, can be applied at various sites

  2. Microwave Radiometry for Oil Pollution Monitoring, Measurements, and Systems

    DEFF Research Database (Denmark)

    Skou, Niels

    1986-01-01

    Work is presently carried out in Europe to change the Status of the microwave radiometer, namely, to develop it from a research instrument to an operational instrument-especially for measuring oil pollution on the sea surface. The Technical University of Denmark (TUD), with its long experience...... in airborne microwave radiometry, is heavily involved in this process. The TUD multichannel imaging radiometer system has been flown in several large-scale oil-pollution experiments, the collected data have been analyzed, and they have revealed that care must be exercised to obtain accurate oil volume...

  3. Measurement results obtained from air quality monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Turzanski, P.K.; Beres, R. [Provincial Inspection of Environmental Protection, Cracow (Poland)

    1995-12-31

    An automatic system of air pollution monitoring operates in Cracow since 1991. The organization, assembling and start-up of the network is a result of joint efforts of the US Environmental Protection Agency and the Cracow environmental protection service. At present the automatic monitoring network is operated by the Provincial Inspection of Environmental Protection. There are in total seven stationary stations situated in Cracow to measure air pollution. These stations are supported continuously by one semi-mobile (transportable) station. It allows to modify periodically the area under investigation and therefore the 3-dimensional picture of creation and distribution of air pollutants within Cracow area could be more intelligible.

  4. Time stress measurement device: system design and synthesis

    Science.gov (United States)

    Harchani, Noursaied; Jimenez, Fernando; Al-Mohammed, Mohammed; Esteve, Daniel; Courvoisier, M.

    2000-04-01

    System design methodology becomes a strategic activity in the industrial competition. Obtaining substantial reduction of time to market for complex and reliable products is one of the priorities for the manufacturers. Top down design, automated generation of architecture, co-design, virtual prototyping, etc. are already identified as research topics which have to be privileged. To be efficient, each theoretical contribution must be inserted in a global procedure of project management where complementary elements such as marketing, technico-economic survey, road-mapping, internal know-how,.. must be considered. In this context, this paper will present a design methodology starting from the requirement statement until the technical realization of the product, and applied to the design of a Time Stress Measurement Device for the observation of aeronautical mechanical systems.

  5. Phasor Measurement Units in the Eastern Danish power system

    DEFF Research Database (Denmark)

    Nielsen, Arne Hejde; Pedersen, Knud Ole Helgesen; Jørgensen, Preben

    2006-01-01

    Technology. After power system events data can be extracted and analyzed offline. The purpose of the project is to do research within various utilizations of PMU data. On 8 January 2005 a severe storm passed Denmark, and wind speeds were so high, that wind turbines disconnected from the transmission grid......In the Eastern Danish transmission system four Phasor Measurement Units (PMU’s) are installed at 400 kV and 132 kV voltage level. The PMU’s continuously record voltage and current phasors each 20 ms. Data are stored locally on the PMU’s and are also transferred to a database at Centre for Electric...... because of their self protection. Nysted offshore wind farm was among the wind power units that disconnected from the grid, and PMU data from that event are analyzed. The case illustrates the close relation between voltages, power flows and voltage phase angles over a wide area. The voltage phase angle...

  6. Snow measurement system for airborne snow surveys (GPR system from helicopter) in high mountian areas.

    Science.gov (United States)

    Sorteberg, Hilleborg K.

    2010-05-01

    In the hydropower industry, it is important to have precise information about snow deposits at all times, to allow for effective planning and optimal use of the water. In Norway, it is common to measure snow density using a manual method, i.e. the depth and weight of the snow is measured. In recent years, radar measurements have been taken from snowmobiles; however, few energy supply companies use this method operatively - it has mostly been used in connection with research projects. Agder Energi is the first Norwegian power producer in using radar tecnology from helicopter in monitoring mountain snow levels. Measurement accuracy is crucial when obtaining input data for snow reservoir estimates. Radar screening by helicopter makes remote areas more easily accessible and provides larger quantities of data than traditional ground level measurement methods. In order to draw up a snow survey system, it is assumed as a basis that the snow distribution is influenced by vegetation, climate and topography. In order to take these factors into consideration, a snow survey system for fields in high mountain areas has been designed in which the data collection is carried out by following the lines of a grid system. The lines of this grid system is placed in order to effectively capture the distribution of elevation, x-coordinates, y-coordinates, aspect, slope and curvature in the field. Variation in climatic conditions are also captured better when using a grid, and dominant weather patterns will largely be captured in this measurement system.

  7. Measurements of Conversion Efficiency for a Flat Plate Thermophotovoltaic System Using a Photonic Cavity Test System

    International Nuclear Information System (INIS)

    Brown, E.J.; Ballinger, C.T.; Burger, S.R.; Charache, G.W.; Danielson, L.R.; DePoy, D.M.; Donovan, T.J.; LoCascio, M.

    2000-01-01

    The performance of a 1 cm 2 thermophotovoltaic (TPV) module was recently measured in a photonic cavity test system. A conversion efficiency of 11.7% was measured at a radiator temperature of 1076 C and a module temperature of 29.9 C. This experiment achieved the highest direct measurement of efficiency for an integrated TPV system. Efficiency was calculated from the ratio of the peak (load matched) electrical power output and the heat absorption rate. Measurements of these two parameters were made simultaneously to assure the validity of the measured efficiency value. This test was conducted in a photonic cavity which mimicked a typical flat-plate TPV system. The radiator was a large, flat graphite surface. The module was affixed to the top of a copper pedestal for heat absorption measurements. The heat absorption rate was proportional to the axial temperature gradient in the pedestal under steady-state conditions. The test was run in a vacuum to eliminate conductive and convective heat transfer mechanisms. The photonic cavity provides the optimal test environment for TPV efficiency measurements because it incorporates all important physical phenomena found in an integrated TPV system: high radiator emissivity and blackbody spectral shape, photon recycling, Lambertian distribution of incident radiation and complex geometric effects. Furthermore, the large aspect ratio between radiating surface area and radiator/module spacing produces a view factor approaching unity with minimal photon leakage

  8. DESIGNING COMPANY PERFORMANCE MEASUREMENT SYSTEM USING BALANCE SCORECARD APPROACH

    Directory of Open Access Journals (Sweden)

    Cecep Mukti Soleh

    2015-05-01

    Full Text Available This research aimed to design how to measure company performance by using balance scorecard approach in coal transportation services industry. Depth interview was used to obtain qualitative data determination of strategic objectives, key performance indicators, strategic initiatives, and in charge units for each balanced scorecard perspectives while the quantitative data were obtained from weighting through questionnaires and analyzed using paired comparison to get a perspective what mostly affected the performance of the company. To measure the achievement of corporate performance, each KPI used (1 the scoring system with the methods that higher is better, lower is better and precise is better; (2 traffic light system with the help of green, yellow, red for identification of target achievement. This research result shows that in the balance scorecard perspective, the most influences on the overall performance of the company include the customer's perspective (31%, financial perspective (29%, internal business processes (21%, learning, and growth 19%. Keywords: balance scorecard, paired comparison, coal transportation serviceABSTRAKPenelitian ini bertujuan untuk merancang pengukuran kinerja perusahaan dengan menggunakan pendekatan balance scorecard di industri jasa pengangkutan batu bara. Data kualitatif diperoleh melalui indepth interview digunakan untuk menentukan sasaran strategik, indikator kinerja utama, inisiatif strategi dan penanggungjawab setiap divisi setiap perspektif balance scorecard, sedangkan data kuantitatif digunakan untuk pembobotan melalui kuesioner dan dianalisis dengan menggunakan metode paired comparisson untuk mendapatkan perspektif yang paling berpengaruh terhadap kinerja perusahaan. Ukuran pencapaian kinerja perusahaan dari setiap KPI menggunakan; (1 scoring system dengan bantuan metode higher is better, lower is better dan precise is better;(2 traffic light system dengan menggunakan bantuan warna hijau, kuning, merah

  9. Tape measuring system using linear encoder and digital camera

    Science.gov (United States)

    Eom, Tae Bong; Jeong, Don Young; Kim, Myung Soon; Kim, Jae Wan; Kim, Jong Ahn

    2013-04-01

    and right edges at all intensity levels. The system can measure the line standards up to 2.5 m. The expanded uncertainty for the tape calibration is U = [(0.04)2+ (0.015•L)2]1/2 mm, where L is measured length of the tape or rule in meters. At this system, the long distance measuring instruments such as ultrasonic distance meter or laser displacement sensor can be also calibrated.

  10. A horizontal mobile measuring system for atmospheric quantities

    Directory of Open Access Journals (Sweden)

    J. Hübner

    2014-09-01

    Full Text Available A fully automatic horizontal mobile measuring system (HMMS for atmospheric quantities has been developed. The HMMS is based on the drive mechanism of a garden railway system and can be installed at any location and along any measuring track. In addition to meteorological quantities (temperature, humidity and short-/long-wave down/upwelling radiation, HMMS also measures trace gas concentrations (carbon dioxide and ozone. While sufficient spatial resolution is a problem even for measurements on distributed towers, this could be easily achieved with the HMMS, which has been specifically developed to obtain higher information density about horizontal gradients in a heterogeneous forest ecosystem. There, horizontal gradients of meteorological quantities and trace gases could be immense, particularly at the transition from a dense forest to an open clearing, with large impact on meteorological parameters and exchange processes. Consequently, HMMS was firstly applied during the EGER IOP3 project (ExchanGE processes in mountainous Regions – Intense Observation Period 3 in the Fichtelgebirge Mountains (SE Germany during summer 2011. At a constant 1 m above ground, the measuring track of the HMMS consisted of a straight line perpendicular to the forest edge, starting in the dense spruce forest and leading 75 m into an open clearing. Tags with bar codes, mounted every metre on the wooden substructure, allowed (a keeping the speed of the HMMS constant (approx. 0.5 m s−1 and (b operation of the HMMS in a continuous back and forth running mode. During EGER IOP3, HMMS was operational for almost 250 h. Results show that – due to considerably long response times (between 4 and 20 s of commercial temperature, humidity and the radiation sensors – true spatial variations of the meteorological quantities could not be adequately captured (mainly at the forest edge. Corresponding dynamical (spatial errors of the measurement values were corrected on the basis

  11. Systems Health Care: daily measurement and lifestyle change

    Science.gov (United States)

    Nakajima, Hiroshi; Tsuchiya, Naoki; Shiga, Toshikazu; Hata, Yutaka

    2012-06-01

    Health is quite important to be realized in our daily life. However, its idea covers wide area and has individual dependency. Activities in health care have been widely developed by medical, drag, insurance, food, and other types of industries mainly centering diseases. In this article, systems approach named Systems Health Care is introduced and discussed to generate new and precious values based on measurements in daily life to change lifestyle habits for realizing each health. Firstly, issues related to health such as its definitions are introduced and discussed by centering health rather than disease. In response to the discussions on health, Home and Medical Care is continuously introduced to point out the important role causality between life style and vital signal such as exercise and blood pressure based on detailed sampling time. Systems approaches of Systems Health Care are discussed from various points of views. Real applications of devices and services are used to make the studies and discussions deeper on the subjects of the article.

  12. Measurement and Analysis of Power in Hybrid System

    Directory of Open Access Journals (Sweden)

    Vartika Keshri

    2016-12-01

    Full Text Available Application with renewable energy  sources  such   as solar cell array, wind turbines, or fuel cells have increased significantly during the past decade. To obtain the clean energy, we are using the hybrid solar-wind power generation. Consumers prefer quality power from suppliers. The quality of power can be measured by using parameters such as voltage sag, harmonic and power factor.   To   obtain   quality   power   we   have different topologies. In our paper we present a new possible topology which improves power quality. This paper presents modeling analysis and design of a pulse width modulation voltage source inverter (PWM-VSI to be connected between sources, which supplies energy from a hybrid solar wind energy system to the ac grid. The objective of this paper is to show that, with an adequate control, the converter not only can transfer the dc from hybrid solar wind energy system, but also can improve the power factor and quality power of electrical system. Whenever a disturbance occurs on load side, this disturbance can be minimized using open loop and closed loop control systems.

  13. GaitKeeper: A System for Measuring Canine Gait

    Directory of Open Access Journals (Sweden)

    Cassim Ladha

    2017-02-01

    Full Text Available It is understood gait has the potential to be used as a window into neurodegenerative disorders, identify markers of subclinical pathology, inform diagnostic algorithms of disease progression and measure the efficacy of interventions. Dogs’ gaits are frequently assessed in a veterinary setting to detect signs of lameness. Despite this, a reliable, affordable and objective method to assess lameness in dogs is lacking. Most described canine lameness assessments are subjective, unvalidated and at high risk of bias. This means reliable, early detection of canine gait abnormalities is challenging, which may have detrimental implications for dogs’ welfare. In this paper, we draw from approaches and technologies used in human movement science and describe a system for objectively measuring temporal gait characteristics in dogs (step-time, swing-time, stance-time. Asymmetries and variabilities in these characteristics are of known clinical significance when assessing lameness but presently may only be assessed on coarse scales or under highly instrumented environments. The system consists an inertial measurement unit, containing a 3-axis accelerometer and gyroscope coupled with a standardized walking course. The measurement unit is attached to each leg of the dog under assessment before it is walked around the course. The data by the measurement unit is then processed to identify steps and subsequently, micro-gait characteristics. This method has been tested on a cohort of 19 healthy dogs of various breeds ranging in height from 34.2 cm to 84.9 cm. We report the system as capable of making precise step delineations with detections of initial and final contact times of foot-to-floor to a mean precision of 0.011 s and 0.048 s, respectively. Results are based on analysis of 12,678 foot falls and we report a sensitivity, positive predictive value and F-score of 0.81, 0.83 and 0.82 respectively. To investigate the effect of gait on system performance

  14. Observing System Simulations for ASCENDS: Synthesizing Science Measurement Requirements (Invited)

    Science.gov (United States)

    Kawa, S. R.; Baker, D. F.; Schuh, A. E.; Crowell, S.; Rayner, P. J.; Hammerling, D.; Michalak, A. M.; Wang, J. S.; Eluszkiewicz, J.; Ott, L.; Zaccheo, T.; Abshire, J. B.; Browell, E. V.; Moore, B.; Crisp, D.

    2013-12-01

    The measurement of atmospheric CO2 from space using active (lidar) sensing techniques has several potentially significant advantages in comparison to current and planned passive CO2 instruments. Application of this new technology aims to advance CO2 measurement capability and carbon cycle science into the next decade. The NASA Active Sensing of Carbon Emissions, Nights, Days, and Seasons (ASCENDS) mission has been recommended by the US National Academy of Sciences Decadal Survey for the next generation of space-based CO2 observing systems. ASCENDS is currently planned for launch in 2022. Several possible lidar instrument approaches have been demonstrated in airborne campaigns and the results indicate that such sensors are quite feasible. Studies are now underway to evaluate performance requirements for space mission implementation. Satellite CO2 observations must be highly precise and unbiased in order to accurately infer global carbon source/sink fluxes. Measurement demands are likely to further increase in the wake of GOSAT, OCO-2, and enhanced ground-based in situ and remote sensing CO2 data. The objective of our work is to quantitatively and consistently evaluate the measurement capabilities and requirements for ASCENDS in the context of advancing our knowledge of carbon flux distributions and their dependence on underlying physical processes. Considerations include requirements for precision, relative accuracy, spatial/temporal coverage and resolution, vertical information content, interferences, and possibly the tradeoffs among these parameters, while at the same time framing a mission that can be implemented within a constrained budget. Here, we attempt to synthesize the results of observing system simulation studies, commissioned by the ASCENDS Science Requirements Definition Team, into a coherent set of mission performance guidelines. A variety of forward and inverse model frameworks are employed to reduce the potential dependence of the results on model

  15. Thoracic ROM measurement system with visual bio-feedback: system design and biofeedback evaluation.

    Science.gov (United States)

    Ando, Takeshi; Kawamura, Kazuya; Fujitani, Junko; Koike, Tomokazu; Fujimoto, Masashi; Fujie, Masakatsu G

    2011-01-01

    Patients with diseases such as chronic obstructive pulmonary disease (COPD) need to improve their thorax mobility. Thoracic ROM is one of the simplest and most useful indexes to evaluate the respiratory function. In this paper, we have proposed the prototype of a simple thoracic ROM measurement system with real-time visual bio-feedback in the chest expansion test. In this system, the thoracic ROM is measured using a wire-type linear encoder whose wire is wrapped around the thorax. In this paper, firstly, the repeatability and reliability of measured thoracic ROM was confirmed as a first report of the developed prototype. Secondly, we analyzed the effect of the bio-feedback system on the respiratory function. The result of the experiment showed that it was easier to maintain a large and stable thoracic ROM during deep breathing by using the real-time visual biofeedback system of the thoracic ROM.

  16. Simulation of n-qubit quantum systems. V. Quantum measurements

    Science.gov (United States)

    Radtke, T.; Fritzsche, S.

    2010-02-01

    The FEYNMAN program has been developed during the last years to support case studies on the dynamics and entanglement of n-qubit quantum registers. Apart from basic transformations and (gate) operations, it currently supports a good number of separability criteria and entanglement measures, quantum channels as well as the parametrizations of various frequently applied objects in quantum information theory, such as (pure and mixed) quantum states, hermitian and unitary matrices or classical probability distributions. With the present update of the FEYNMAN program, we provide a simple access to (the simulation of) quantum measurements. This includes not only the widely-applied projective measurements upon the eigenspaces of some given operator but also single-qubit measurements in various pre- and user-defined bases as well as the support for two-qubit Bell measurements. In addition, we help perform generalized and POVM measurements. Knowing the importance of measurements for many quantum information protocols, e.g., one-way computing, we hope that this update makes the FEYNMAN code an attractive and versatile tool for both, research and education. New version program summaryProgram title: FEYNMAN Catalogue identifier: ADWE_v5_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADWE_v5_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 27 210 No. of bytes in distributed program, including test data, etc.: 1 960 471 Distribution format: tar.gz Programming language: Maple 12 Computer: Any computer with Maple software installed Operating system: Any system that supports Maple; the program has been tested under Microsoft Windows XP and Linux Classification: 4.15 Catalogue identifier of previous version: ADWE_v4_0 Journal reference of previous version: Comput. Phys. Commun

  17. A Hydraulic Stress Measurement System for Deep Borehole Investigations

    Science.gov (United States)

    Ask, Maria; Ask, Daniel; Cornet, Francois; Nilsson, Tommy

    2017-04-01

    Luleå University of Technology (LTU) is developing and building a wire-line system for hydraulic rock stress measurements, with funding from the Swedish Research Council and Luleå University of Technology. In this project, LTU is collaborating with University of Strasbourg and Geosigma AB. The stress state influences drilling and drillability, as well as rock mass stability and permeability. Therefore, knowledge about the state of in-situ stress (stress magnitudes, and orientations) and its spatial variation with depth is essential for many underground rock engineering projects, for example for underground storage of hazardous material (e.g. nuclear waste, carbon dioxide), deep geothermal exploration, and underground infrastructure (e.g. tunneling, hydropower dams). The system is designed to conduct hydraulic stress testing in slim boreholes. There are three types of test methods: (1) hydraulic fracturing, (2) sleeve fracturing and (3) hydraulic testing of pre-existing fractures. These are robust methods for determining in situ stresses from boreholes. Integration of the three methods allows determination of the three-dimensional stress tensor and its spatial variation with depth in a scientific unambiguously way. The stress system is composed of a downhole and a surface unit. The downhole unit consists of hydraulic fracturing equipment (straddle packers and downhole imaging tool) and their associated data acquisition systems. The testing system is state of the art in several aspects including: (1) Large depth range (3 km), (2) Ability to test three borehole dimensions (N=76 mm, H=96 mm, and P=122 mm), (3) Resistivity imager maps the orientation of tested fracture; (4) Highly stiff and resistive to corrosion downhole testing equipment; and (5) Very detailed control on the injection flow rate and cumulative volume is obtained by a hydraulic injection pump with variable piston rate, and a highly sensitive flow-meter. At EGU General Assembly 2017, we would like to

  18. Clustering-driven residue filter for profile measurement system.

    Science.gov (United States)

    Jiang, Jun; Cheng, Jun; Zhou, Ying; Chen, Guang

    2011-02-01

    The profile measurement system is widely used in industrial quality control, and phase unwrapping (PU) is a key technique. An algorithm-driven PU is often used to reduce the impact of noise-induced residues to retrieve the most reliable solution. However, measuring speed is lowered due to the searching of optimal integration paths or correcting of phase gradients. From the viewpoint of the rapidity of the system, this paper characterizes the noise-induced residues, and it proposes a clustering-driven residue filter based on a set of directional windows. The proposed procedure makes the wrapped phases included in the filtering window have more similar values, and it groups the correct and noisy phases into individual clusters along the local fringe direction adaptively. It is effective for the tightly packed fringes, and it converts the algorithm-driven PU to the residue-filtering-driven one. This improves the operating speed of the 3D reconstruction significantly. The tests performed on simulated and real projected fringes confirm the validity of our approach.

  19. Laser Doppler detection systems for gas velocity measurement.

    Science.gov (United States)

    Huffaker, R M

    1970-05-01

    The velocity of gas flow has been remotely measured using a technique which involves the coherent detection of scattered laser radiation from small particles suspended in the fluid utilizing the doppler effect. Suitable instrumentation for the study of wind tunnel type and atmospheric flows are described. Mainly for reasons of spatial resolution, a function of the laser wavelength, the wind tunnel system utilizes an argon laser operating at 0.5 micro. The relaxed spatial resolution requirement of atmospheric applications allows the use of a carbon dioxide laser, which has superior performance at a wavelength of 10.6 micro, a deduction made from signal-to-noise ratio considerations. Theoretical design considerations are given which consider Mie scattering predictions, two-phase flow effects, photomixing fundamentals, laser selection, spatial resolution, and spectral broadening effects. Preliminary experimental investigations using the instrumentation are detailed. The velocity profile of the flow field generated by a 1.27-cm diam subsonic jet was investigated, and the result compared favorably with a hot wire investigation conducted in the same jet. Measurements of wind velocity at a range of 50 m have also shown the considerable promise of the atmospheric system.

  20. Measurement system for special surface mapping using miniature displacement sensors

    Directory of Open Access Journals (Sweden)

    Zowade Martyna

    2018-01-01

    Full Text Available The aim of the work was to design a special system for measurements of elements with repetitive geometry or assemblies with repeating components, set in a linear patterns. The main focus was based on developing a computer program for signal analysis from variable number of miniature displacement sensors. It was set that the response for displacement of measuring tip from each sensor was a 0-5 V voltage signal with possibility of using different type of sensors. Requirements were determined based on projected measurement method. A special design of sensor was made for testing the computer program. If the characteristics of the sensor is known, it is possible to compute the type A evaluation of uncertainty. The results are presented in XY chart on computer screen. The program allows the user to choose any number of the sensors and determine the distance between them. Also, the possibility of calibration of sensors’ set was provided. The test were conducted on a prototype handle for sensors, made on a 3D printer.