WorldWideScience

Sample records for surface radiological investigation

  1. Entrance surface dose of the common radiological investigations in ...

    African Journals Online (AJOL)

    The entrance surface Dose (ESD) was determined among patients who presented for routine radiological examinations using thermoluminescent dosimeter (TLD) chips placed on averagely built adult [ (30cm) chest width, 60 - 90kg weight and 20-40years)] by multiplying the incident dose/entrances dose by the back ...

  2. Characterization Investigation Study: Volume 3, Radiological survey of surface soils

    Energy Technology Data Exchange (ETDEWEB)

    Solow, A.J.; Phoenix, D.R.

    1987-12-01

    The Feed Materials Production Center was constructed to produce high purity uranium metal for use at various Department of Energy facilities. The waste products from these operations include general uncontaminated scrap and refuse, contaminated and uncontaminated metal scrap, waste oils, low-level radioactive waste, co-contaminated wastes, mixed waste, toxic waste, sludges from water treatment, and fly ash from the steam plant. This material is estimated to total more than 350,000 cubic meters. Other wastes stored in this area include laboratory chemicals and other combustible materials in the burn pit; fine waste stream sediments in the clear well; fly ash and waste oils in the two fly ash areas; lime-alum sludges and boiler plant blowdown in the lime sludge ponds; and nonradioactive sanitary waste, construction rubble, and asbestos in the sanitary landfill. A systematic survey of the surface soils throughout the Waste Storage Area, associated on-site drainages, and the fly ash piles was conducted using a Field Instrument for Detecting Low-Energy Radiation (FIDLER). Uranium is the most prevalent radioactive element in surface soil; U-238 is the principal radionuclide, ranging from 2.2 to 1790 pCi/g in the general Waste Storage Area. The maximum values for the next highest activity concentrations in the same area were 972 pCi/g for Th-230 and 298 pCi/g for U-234. Elevated activity concentrations of Th-230 were found along the K-65 slurry line, the maximum at 3010 pCi/g. U-238 had the highest value of 761 pCi/g in the drainage just south of pit no. 5. The upper fly ash area had the highest radionuclide activity concentrations in the surface soils with the maximum values for U-238 at 8600 pCi/g, U-235 at 2190 pCi/g, U-234 at 11,400 pCi/g, Tc-99 at 594 pCi/g, Ra-226 at 279 pCi/g, and Th-230 at 164 pCi/g.

  3. Surface radiological investigations along State Highway 95, Lagoon Road, and Melton Valley Drive, Oak Ridge Reservation, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Tiner, P.F.; Uziel, M.S.; Rice, D.E.; Williams, J.K.

    1995-08-01

    The surface radiological investigation along State Highway 95, Lagoon Road, and Melton Valley Drive at the Oak Ridge Reservation was conducted as part of the Oak Ridge National Laboratory Environmental Restoration Program Surveillance and Maintenance activities. This report was prepared to document results of the investigation and subsequent remedial actions. The report details surface gamma radiation levels including gamma anomalies; surface beta radiation levels including beta anomalies; results of analysis of soil, water, and vegetation samples and smear samples collected from paved surfaces; remediation activities conducted as a result of the survey; and recommendations for further corrective measures

  4. Surface radiological investigation of Trench 5 in Waste Area Grouping 7 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Goff, D.D.

    1991-08-01

    A surface radiological investigation of areas encompassing Trench 5 on the Oak Ridge Reservation (ORR) was conducted from May 1990 through November 1990. This survey was led by the author, assisted by various members of the Measurement Applications and Development (MAD) group of the Health and Safety Research Division (HASRD) of Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee. The purpose of the investigation was to determine the presence, nature, and extent of surface radiological contamination at Trench 5, the Homogeneous Reactor Experiment fuel wells, and surrounding areas. Based on the data obtained in the field, interim corrective measures were recommended to limit human exposure to radioactivity and to minimize insult to the environment. It should be stressed that this project was not intended to be a complete site characterization but rather to be a preliminary investigation into the potential contamination problem that might exist as a result of past operations at Trench 5

  5. Surface radiological investigation of Trench 5 in Waste Area Grouping 7 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Goff, D.D.

    1991-08-01

    A surface radiological investigation of areas encompassing Trench 5 on the Oak Ridge Reservation (ORR) was conducted from May 1990 through November 1990. This survey was led by the author, assisted by various members of the Measurement Applications and Development (MAD) group of the Health and Safety Research Division (HASRD) of Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee. The purpose of the investigation was to determine the presence, nature, and extent of surface radiological contamination at Trench 5, the Homogeneous Reactor Experiment fuel wells, and surrounding areas. Based on the data obtained in the field, interim corrective measures were recommended to limit human exposure to radioactivity and to minimize insult to the environment. It should be stressed that this project was not intended to be a complete site characterization but rather to be a preliminary investigation into the potential contamination problem that might exist as a result of past operations at Trench 5.

  6. Epilepsy and radiological investigations

    International Nuclear Information System (INIS)

    Tomberg, T.

    2005-01-01

    Epilepsy is a heterogenous group of disorders with multiple causes. Clinical management of epilepsy patients requires knowledge of seizure syndromes, causes, and imaging features. The aim of radiological investigations is to recognize the underlying cause of epilepsy. The main indications for neuroimaging studies are partial and secondarily generalized seizures, patients with neurological signs and intractable seizures, and patients with focal signs on EEG. Partial seizures of any type are more likely to be associated with a focus that may be identified on neuroimaging. MRI is the method of choice for evaluating structural abnormalities of the brain. High resolution MRI and dedicated imaging technique are needed for detection of subtle pathological changes as cortical dysplasias and temporal medial sclerosis. Other lesions that may be detected include neoplasms, vascular malformations, destructive lesions following brain injury, stroke, infection, etc. CT continues to be the technique for the investigation of patients with seizures under certain conditions. New techniques such as functional MRI, MR spectroscopy, SPECT, receptor PET and magnetic source imaging are becoming clinical tools for improving diagnosis [et

  7. Surface radiological investigation of Trench 5 in Waste Area Grouping 7 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    Energy Technology Data Exchange (ETDEWEB)

    Goff, D.D.

    1991-08-01

    A surface radiological investigation of areas encompassing Trench 5 on the Oak Ridge Reservation (ORR) was conducted from May 1990 through November 1990. This survey was led by the author, assisted by various members of the Measurement Applications and Development (MAD) group of the Health and Safety Research Division (HASRD) of Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee. The purpose of the investigation was to determine the presence, nature, and extent of surface radiological contamination at Trench 5, the Homogeneous Reactor Experiment fuel wells, and surrounding areas. Based on the data obtained in the field, interim corrective measures were recommended to limit human exposure to radioactivity and to minimize insult to the environment. It should be stressed that this project was not intended to be a complete site characterization but rather to be a preliminary investigation into the potential contamination problem that might exist as a result of past operations at Trench 5.

  8. Surface radiological investigations of Trench 6 and low-level waste Line Leak Site 7. 4b at the Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Uziel, M.S.; Tiner, P.F.; Williams, J.K.

    1991-08-01

    A surface radiological investigation of Trench 6 and low-level radioactive waste (LLW) Line Leak Site 7.4b was conducted in July and August 1989 and January 1990 by the Measurement Applications and Development Group, Oak Ridge National Laboratory. The purposes of this survey were (1) to determine the presence, nature, and extent of surface radiological contamination and (2) to recommend interim corrective action to limit human exposures to radioactivity and minimize the potential for contaminant dispersion. Highest surface gamma levels encountered during the survey (39 mR/h) were found just south of the asphalt covering LLW Line Leak Site 7.4b. Elevated surface gamma levels (measuring 28 to 560 {mu}R/h) extended from this area to a width of 100 ft, westward 250 ft, and beyond the survey boundary. Beta-gamma levels up to 17 mrad/h measured on contact with the trunks of trees growing in the area southwest of Trench 6 suggest that three roots are reaching contamination deep within the ground. Since no gamma activity is associated with the trees or their leaves, the elevated beta levels are probably due to the uptake of residual {sup 90}Sr originating from the documented seepage at the Trench 6/Leak Site 7.4b area. Beta activity present in the leaf litter and surface soil indicate that decaying leaves are depositing measurable contaminants on the ground surface. Recommendations for corrective actions are included. 7 refs., 20 figs., 3 tabs.

  9. Radiological investigation of drinking water

    International Nuclear Information System (INIS)

    Kunz, E.

    1981-01-01

    An analysis is made of the report ''Radiological investigation of drinking water'' submitted by a working group of WHO to the Brussels meeting held between Nov 7 and 10, 1978. Annex II is emphasized of the WHO publication bearing the title ''The revision of WHO standards for drinking water''. It is shown that the draft of the revision does not basically differ from the revision introduced in Czechoslovakia and published in a revised standard CSN 83 0611 Drinking Water from 1978, including its harmonization with the Decree 59/72 Collect. of Laws on the protection of health from ionizing radiation, and from the standard CSN 83 0523 Radiometric analysis of drinking water. It is also shown that the text of the working group report contains some incorrect or unclear statements and views, which is explained by the misunderstanding of some ICRP recommendations. (H.S.)

  10. Radiological monitoring. Controlling surface water pollution

    International Nuclear Information System (INIS)

    Morin, Maxime

    2018-01-01

    Throughout France, surface waters (from rivers to brooks) located at the vicinity of nuclear or industrial sites, are subject to regular radiological monitoring. An example is given with the radiological monitoring of a small river near La Hague Areva's plant, where contaminations have been detected with the help of the French IRSN nuclear safety research organization. The sampling method and various measurement types are described

  11. Paleontology investigations aided by medical radiology

    International Nuclear Information System (INIS)

    Lansu, M.J.; Carpenter, K.; Albano, J.; Meals, R.; Brady, L.W.

    1987-01-01

    Medical radiology instruments provide useful tools for nondestructive investigations in other scientific fields. To date, 15 paleontology specimens have been studied using conventional diagnostic units, therapy simulators, and CT scanners. Most specimens, individual marine animals or large dinosaur heads, needed a combination of studies to complete the investigation. Among the results shown are the inner ear of a Plesiosaurus, which is 76 million years old, and a pearl attached to an extinct clam species, which is 1 million years old. The results confirm the usefulness of radiology as a tool in the field of paleontology

  12. The radiologic decontamination of metal surfaces with new emulsion system

    International Nuclear Information System (INIS)

    Stjepanovic, N.; Mladenovic, V.; Lukovic, Z.; Ivkovic, S.

    1999-01-01

    The efficiencies of the emulsion FN-10 and FN-6 and detergent DV-60 in the radiological decontamination were investigated. The metal surfaces, clean and dirty, were contaminated with Cs-137, and decontaminated with water and appropriate solution. The most efficiency of DV-60 in both cases, was obtained. (author)

  13. Left behind radiological investigations: An inherent problem

    Directory of Open Access Journals (Sweden)

    Giridhar A Govindswamy

    2011-01-01

    Full Text Available Objectives: To assess the number of investigations left behind by patients in radiology department, their cost, and the possible methods of reducing the problem. Materials and Methods: A total of 1424 radiographs, 160 computed tomography (CT scans, 300 ultrasonography (USG reports, and 46 Doppler reports were left behind by patients in one financial year. The total cost of these left behind investigations was calculated and the reports were categorized into normal and abnormal for each modality. Results: Of the radiographs left behind 658 were abnormal, with 211 among these being radiographs of postoperative patients. Thirty-seven percent of CT scans had positive findings. Sixty-eight percent of USG reports had positive findings while 46% of Doppler reports were abnormal. Conclusion: We believe that the cost and number of these left behind investigations over a period of time would definitely be significant for the health care system in a developing country. It is time to think of the possible reasons and methods for containing this problem.

  14. Correlation of radiological investigations with clinical findings in ...

    African Journals Online (AJOL)

    Correlation of radiological investigations with clinical findings in cases of abdominal mass in the paediatric age group. N Sharma, V Dutt, M Sharma. Abstract. Background: The aim of the following study is to find out the accuracy of clinical examination and radiological investigations in determining the organ of origin and ...

  15. Radiologic investigation after laparoscopic inguinal hernia repair

    Energy Technology Data Exchange (ETDEWEB)

    Larmark, Martin; Ekberg, Olle [Department of Diagnostic Radiology, Malmoe University Hospital, 205 02, Malmoe (Sweden); Montgomery, Agneta [Department of Surgery, Malmoe University Hospital, 205 02, Malmoe (Sweden)

    2003-12-01

    Laparoscopic instead of open surgical repair of inguinal hernias is becoming more frequent. Radiologists may expect different postoperative findings depending on the technique used. We studied how radiology had been used postoperatively and what findings were encountered after laparoscopic herniorraphy. Postoperative radiologic examinations related to hernia repair of all consecutive patients that had had laparoscopic herniorraphy in Malmoe University hospital between 1992 and 1998 were retrospectively evaluated. A total of 538 groins were included, 3.9% (n=21) of these were postoperatively examined with ultrasound (n=10), herniography (n=7), plain abdominal films (n=2), CT (n=1), or fistulography (n=1). Significant findings were found in five groins, namely, one sinus tract, two hematomas, one small bowel obstruction, and one recurrence of hernia. Four insignificant seromas were found. The characteristics of the findings and pitfalls are described. Symptoms resulting in radiologic examination are rare after laparoscopic herniorraphy. The radiologist must be familiar with the spectrum of such findings. (orig.)

  16. Radiological investigation of phosphate fertilizers: Leaching studies.

    Science.gov (United States)

    Hegedűs, Miklós; Tóth-Bodrogi, Edit; Németh, Szabolcs; Somlai, János; Kovács, Tibor

    2017-07-01

    The raw materials of the phosphate fertilizer industry are the various apatite minerals. Some of these have high levels of natural radionuclides, and thus phosphate fertilizers contain significant amounts of U-238, K-40 and Ra-226. These can leach out of the fertilizers used in large quantities for resupplying essential nutrients in the soil and can then enter the food chain through plants, thereby increasing the internal dose of the affected population. In the current study, the radiological risk of eight commercially available phosphate fertilizers (superphosphate, NPK, PK) and their leaching behaviours were investigated using different techniques (gamma and alpha spectrometry), and the dose contributions of using these fertilizers were estimated. To characterize the leaching behaviour, two leaching procedures were applied and compared -the MSZ 21470-50 (Hungarian standard) and the Tessier five-step sequential extraction method. Based on the evaluation of the gamma-spectra, it is found that the level of Th-232 in the samples was low (max.7 ± 6 Bq kg -1 ), the average Ra-226 activity concentration was 309 ± 39 Bq kg -1 (min. 10 ± 8 Bq kg -1 , max. 570 ± 46 Bq kg -1 ), while the K-40 concentrations (average 3139 ± 188 Bq kg -1 , min. 51 ± 36 Bq kg -1 ) could be as high as 7057 ± 427 Bq kg -1 . The high K-40 can be explained by reference to the composition of the investigated fertilizers (NPK, PK). U concentrations were between 15 and 361 Bq kg -1 , with the average of 254 Bq kg -1 , measured using alpha spectrometry. The good correlation between P 2 O 5 content and radioactivity reported previously is not found in our data. The leaching studies reveal that the mobility of the fertilizer's uranium content is greatly influenced by the parameters of the leaching methods. The availability of U to water ranged between 3 and 28 m/m%, while the Lakanen-Erviö solution mobilized between 10 and 100% of the U content. Copyright © 2016

  17. A Survey of Preoperative Radiological Investigation Among Dental ...

    African Journals Online (AJOL)

    A Survey of Preoperative Radiological Investigation Among Dental Professionals carrying out Impacted Lower third Molar Surgery in Eastern Nigeria. ... West African Journal of Radiology. Journal Home ... Fortyeight were returned anonymously representing 85.7% response rate, which were used in our data analysis.

  18. Radiological investigation of neurofibromatosis type 2

    International Nuclear Information System (INIS)

    AAkeson, P.; Holtaas, S.

    1994-01-01

    The radiological findings in six patients fulfilling the criteria of neurofibromatosis type 2 (NF2) were reviewed. Subtle cutaneous lesions were found in three. All patients had bilateral acoustic schwannomas; two had small acoustic tumours and normal hearing. In these patients the presenting symptoms were caused by multiple intracranial meningiomas and spinal neurofibromas, respectively, whereas the remaining four patients presented with hearing loss. Two patients had other cranial nerve tumours. Three patients had rapidly growing multiple intracranial meningiomas; two had multiple spinal neurofibromas and one a spinal meningioma. NF2 is a rare disease with few cutaneous but frequent, typical radiological findings in the central nervous system. The presenting symptom is most commonly hearing loss due to acoustic schwannomas, although symptoms emanating from other intracranial or tumours are not uncommon. The discovery of multiple meningiomas or multiple spinal neurofibromas without cutaneous lesions should initiate a search for acoustic schwannomas even when the patient has normal hearing. (orig.)

  19. Fine tuning of work practices of common radiological investigations performed using computed radiography system

    International Nuclear Information System (INIS)

    Livingstone, Roshan S.; Timothy Peace, B.S.; Sunny, S.; Victor Raj, D.

    2007-01-01

    Introduction: The advent of the computed radiography (CR) has brought about remarkable changes in the field of diagnostic radiology. A relatively large cross-section of the human population is exposed to ionizing radiation on account of common radiological investigations. This study is intended to audit radiation doses imparted to patients during common radiological investigations involving the use of CR systems. Method: The entrance surface doses (ESD) were measured using thermoluminescent dosimeters (TLD) for various radiological investigations performed using the computed radiography (CR) systems. Optimization of radiographic techniques and radiation doses was done by fine tuning the work practices. Results and conclusion: Reduction of radiation doses as high as 47% was achieved during certain investigations with the use of optimized exposure factors and fine-tuned work practices

  20. Entrance surface dose measurements in pediatric radiological examinations

    International Nuclear Information System (INIS)

    Ribeiro, L.A.; Yoshimura, E.M.

    2008-01-01

    A survey of pediatric radiological examinations was carried out in a reference pediatric hospital of the city of Sao Paulo, in order to investigate the doses to children undergoing conventional X-ray examinations. The results showed that the majority of pediatric patients are below 4 years, and that about 80% of the examinations correspond to chest projections. Doses to typical radiological examinations were measured in vivo with thermoluminescent dosimeters (LiF: Mg, Ti and LiF: Mg, Cu, P) attached to the skin of the children to determine entrance surface dose (ESD). Also homogeneous phantoms were used to obtain ESD to younger children, because the technique uses a so small kVp that the dosimeters would produce an artifact image in the patient radiograph. Four kinds of pediatric examinations were investigated: three conventional examinations (chest, skull and abdomen) and a fluoroscopic procedure (barium swallow). Relevant information about kVp and mAs values used in the examinations was collected, and we discuss how these parameters can affect the ESD. The ESD values measured in this work are compared to reference levels published by the European Commission for pediatric patients. The results obtained (third-quartile of the ESD distribution) for chest AP examinations in three age groups were: 0.056 mGy (2-4 years old); 0.068 mGy (5-9 years old); 0.069 mGy (10-15 years old). All of them are below the European reference level (0.100 mGy). ESD values measured to the older age group in skull and abdomen AP radiographs (mean values 3.44 and 1.20 mGy, respectively) are above the European reference levels (1.5 mGy to skull and 1.0 mGy to abdomen). ESD values measured in the barium swallow examination reached 10 mGy in skin regions corresponding to thyroid and esophagus. It was noticed during this survey that some technicians use, improperly, X-ray fluoroscopy in conventional examinations to help them in positioning the patient. The results presented here are a

  1. Surface with two paint strips for detection and warning of chemical warfare and radiological agents

    Science.gov (United States)

    Farmer, Joseph C.

    2013-04-02

    A system for warning of corrosion, chemical, or radiological substances. The system comprises painting a surface with a paint or coating that includes an indicator material and monitoring the surface for indications of the corrosion, chemical, or radiological substances.

  2. Entrance surface dose in cerebral interventional radiology procedures

    International Nuclear Information System (INIS)

    Barrera-Rico, M.; López-Rendón, X.; Rivera-Ordóñez, C. E.; Gamboa-deBuen, I.

    2012-01-01

    At the Instituto Nacional de Neurología y Neurocirugía (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 ×1 cm 2 of Gafchromic XR-QA2 film bound in a holder of 15×15 cm 2 in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.

  3. Entrance surface dose in cerebral interventional radiology procedures

    Energy Technology Data Exchange (ETDEWEB)

    Barrera-Rico, M.; Lopez-Rendon, X.; Rivera-Ordonez, C. E.; Gamboa-deBuen, I. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, 04510 DF (Mexico); Instituto Nacional de Neurologia y Neurocirugia Manuel Velasco Suarez, 14269 DF (Mexico); Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, 04510 DF (Mexico)

    2012-10-23

    At the Instituto Nacional de Neurologia y Neurocirugia (INNN) diagnostic as well as therapeutic procedures of interventional radiology are carried out. Since the procedures can last from some minutes to several hours, the absorbed dose for the patient could increase dangerously. An investigation had begun in order to determine the entrance surface dose (ESD) using 25 thermoluminiscent dosimeters TLD-100 and 8 strips of 15 Multiplication-Sign 1 cm{sup 2} of Gafchromic XR-QA2 film bound in a holder of 15 Multiplication-Sign 15 cm{sup 2} in the posteroanterior (PA) and lateral (LAT) positions during all the procedure. The results show that maximum ESD could be from 0.9 to 2.9 Gy for the PA position and between 1.6 and 2.5 Gy for the lateral position. The average ESD was between 0.7 and 1.3 Gy for the PA position, and from 0.44 to 1.1 Gy for the lateral position in a therapeutic procedure.

  4. Radiology

    International Nuclear Information System (INIS)

    Edholm, P.R.

    1990-01-01

    This is a report describing diagnostic techniques used in radiology. It describes the equipment necessary for, and the operation of a radiological department. Also is described the standard methods used in radiodiagnosis. (K.A.E.)

  5. Analysis of body surface radiological contamination for inbound people from Japan to China during the Fukushima nuclear accident

    International Nuclear Information System (INIS)

    Yuan Long; Ma Weidong; Lei Cuiping; Chen Huifang; Li Yuwen; Liu Ying

    2012-01-01

    Objective: To investigate the radiological contamination of body surface for inbound people from Japan to China during Fukushima nuclear accident. Methods: According to The guidance for radiological contamination management for body surface issued by Chinese Center for Disease Control and Prevention, for people evacuated from Japan, the body surface monitoring of radiological contamination was performed by the related agencies in main provinces and cities in China. The monitoring data were collected, analyzed and reported to Ministry of Health. Results: A total of 432 persons were checked. The monitoring results of 429 cases were close to the background level, while those of three persons were higher than the background level. Conclusions: In general,the detected results were as low as the background level. The radiological contamination monitoring of body surface for people from Japan could provide scientific data to relax the horror and panic among them. (authors)

  6. CRRIS: a computerized radiological risk-investigation system

    International Nuclear Information System (INIS)

    Baes, C.F. III; Miller, C.W.

    1981-01-01

    The US Environmental Protection Agency (EPA) is responsible for regulating radioactive airborne effluents in the US. A comprehensive, integrated Computerized Radiological Risk Investigation System (CRRIS) is being developed to support EPA's radiation standards development. This modular system consists primarily of five computer codes and their supporting data bases for estimating environmental transport and radiation doses and risks. Health effects are estimated on the basis of a life-table methodology developed by EPA. CRRIS is designed to provide EPA with a reasonable and flexible way of assessing the risk to man associated with radionuclide releases to the atmosphere

  7. Entrance surface dose in cerebral interventional radiology procedures

    International Nuclear Information System (INIS)

    Barrera-Rico, M.; López-Rendón, X.; Vega-Montesino, S.; Gamboa-deBuen, I.

    2014-01-01

    During interventional radiology procedures patients receive doses which exceed thresholds for non-stochastic effects on the skin, such as erythema (2 Gy) and epilation (3 Gy), so the entrance surface dose imparted during these proceedings should be monitored. The aim of this work was to determine the entrance surface dose (ESD) in patients who undergo diagnostic or therapeutic procedures at the Instituto Nacional de Neurología y Neurocirugía (INNN). The procedures were performed using two systems for neuroradiology, an Axiom Artis and an Artis Zeego from Siemens. The ESD was measured, for diagnostic and therapeutic procedures, using 15 × 15 cm 2 of Gafchromic XR-RV3 film and/or 25 TLD-100 chips that were attached in a holder of 15 × 15 cm 2 in the posteroanterior and left and right lateral positions during all the procedures. The results show that the maximum ESD measured was lower than 1 Gy for the nine diagnostic procedures evaluated whereas four of the ten therapeutic procedures were greater than 2 Gy in at least one position. Seven patients were monitored, three of which have presented epilation and one erythema. - Highlights: • We measured the entrance surface dose in cerebral interventional radiology. • Entrance surface doses were lower than 1 Gy for diagnostic procedures. • In four therapeutic procedures entrance surface doses were greater than 2 Gy. • Three patients presented epilation and one erythema

  8. Investigation of radiological properties and water equivalency of PRESAGE dosimeters.

    Science.gov (United States)

    Gorjiara, Tina; Hill, Robin; Kuncic, Zdenka; Adamovics, John; Bosi, Stephen; Kim, Jung-Ha; Baldock, Clive

    2011-04-01

    PRESAGE is a dosimeter made of polyurethane, which is suitable for 3D dosimetry in modern radiation treatment techniques. Since an ideal dosimeter is radiologically water equivalent, the authors investigated water equivalency and the radiological properties of three different PRESAGE formulations that differ primarily in their elemental compositions. Two of the formulations are new and have lower halogen content than the original formulation. The radiological water equivalence was assessed by comparing the densities, interaction probabilities, and radiation dosimetry properties of the three different PRESAGE formulations to the corresponding values for water. The relative depth doses were calculated using Monte Carlo methods for 50, 100, 200, and 350 kVp and 6 MV x-ray beams. The mass densities of the three PRESAGE formulations varied from 5.3% higher than that of water to as much as 10% higher than that of water for the original formulation. The probability of photoelectric absorption in the three different PRESAGE formulations varied from 2.2 times greater than that of water for the new formulations to 3.5 times greater than that of water for the original formulation. The mass attenuation coefficient for the three formulations is 12%-50% higher than the value for water. These differences occur over an energy range (10-100 keV) in which the photoelectric effect is the dominant interaction. The collision mass stopping powers of the relatively lower halogen-containing PRESAGE formulations also exhibit marginally better water equivalency than the original higher halogen-containing PRESAGE formulation. Furthermore, the depth dose curves for the lower halogen-containing PRESAGE formulations are slightly closer to that of water for a 6 MV beam. In the kilovoltage energy range, the depth dose curves for the lower halogen-containing PRESAGE formulations are in better agreement with water than the original PRESAGE formulation. Based on the results of this study, the new

  9. Radiology

    International Nuclear Information System (INIS)

    Sykora, A.

    2006-01-01

    In this text-book basic knowledge about radiology, biomedical diagnostic methods (radiography, computer tomography), nuclear medicine and safety and radiation protection of personnel on the radiodiagnostic place of work are presented

  10. Radiological data acquisition, investigation and evaluation of mining relics

    International Nuclear Information System (INIS)

    1992-01-01

    Within the scope of a Federal Project, the environmental radioactivity and the radon concentration in buildings caused by mining relics in the new Federal Lands of Germany are investigated. In the first phase of the project, about 8000 relics of former mining were identified by analysing existing documents, categorised, and recorded in a special data bank. Thereby, 'areas of suspicion' of 1500 km 2 spaciously defined in the beginning could be reduced to 'areas of investigation' of 250 km 2 now to be examined in close coordination with the land and district authorities by a programme gradually adapted to the radiological significance of the relics. Experience with site-specific measuring programmes have already been gained through three pilot projects at typical sites of former mining activities. Recommendations of the German Radiation Protection Commission serve for the evaluation of the results. By the measuring programme for radon in buildings of mining and geological predestined regions more than 25000 buildings of 210 communities have been investigated. The results confirm the expected prevailing influence of the geologic underground on the radon concentration. Extreme values are observed where direct connections additionally exist to mining relics in the ground. (orig./HP) With 11 figs. in annex [de

  11. Back injuries in young fast bowlers - a radiological investigation of ...

    African Journals Online (AJOL)

    Objective. To demonstrate the efficacy of various radiological diagnostic modalities in assessing lower back pain in young fast bowlers. Methods. Ten cricketers who presented to either a physiotherapist or a doctor with suspected spondylolysis underwent an X-ray, a single photon emission computed tomography (SPECT) ...

  12. Digital radiological research in forensic dental investigation: case studies.

    Science.gov (United States)

    Nuzzolese, E; Di Vella, G

    2012-04-01

    The advent of dental digital radiology and new portable X-ray devices allows the execution of periapical X-ray images not only in the dental surgery but also in hitherto difficult locations such as field military hospitals, archaeological excavation sites, morgues and in cases of house arrest. In this work authors evaluated the feasibility of Nomad Examiner (Aribex inc.) handheld X-ray device combined with a digital sensor and a portable pc in forensic odontology applications. Employed for the first time forensically during the 2004 Tsunami victim identification process, the Nomad Examiner has now passed all security and conformity requirements of US and EU regulations. Examples of the practical use and the technical features of this device are seen when employed in odontological assessment of skeletonised and carbonized individuals and the assessment of individuals under house arrest complaining dental lesions. Results from the use this portable device demonstrate the benefits of a dental radiological assessment during an autopsy with the aim of human identification and the importance of a complete dental assessment (clinical and radiological) when evaluating dental traumatic lesions of individuals who cannot visit a dental surgery. In the first example forensic dentist would work alongside a forensic pathologist. On the other hand in the second example an odontologist - dentist could be appointed as an expert witness directly by a Court.

  13. The Mobile Surface Contamination Monitor II environmental radiological characterization utilizing GPS/GIS technologies

    International Nuclear Information System (INIS)

    Wendling, M.A.

    1993-05-01

    Time, cost, and most importantly quality of data are the three factors to measure the success of field radiological characterizations. The application of coupling radiation detection instrumentation to a GPS receiver has dramatically increased the data quality achievable compared to traditional environmental radiological survey methods. Improvements in verifying adequate spatial coverage of an area while collecting data and at,the same time reducing field time requirements can be realized. Data acquired during the recent implementation of the Mobile Surface Contamination Monitor 11 (MSCM-11) will be presented to demonstrate the advantages of this system over traditional radiological survey methods. The comparison will include time and manpower requirements. Linking the complimentary GPS, GIS and radiation detection technologies on a mobile tractor based platform has provided a tool to provide radiological characterization data faster, cheaper, and better to assist in the Environmental Restoration Mission of the Hanford Site

  14. Publication Rates for Abstracts Presented by Korean Investigators at Major Radiology Meetings

    International Nuclear Information System (INIS)

    Ha, Tae Ho; Yoon, Dae Young; Goo, Dong Hyun; Chang, Suk Ki; Seo, Young Lan; Yun, Eun Joo; Moon, Jeung Hee; Lee, Yu Jin; Lim, Kyoung Ja; Choi, Chul Soon

    2008-01-01

    To determine the publication rate of abstracts presented by Korean investigators at national and international radiological meetings, and to identify predictive factors of publication. Abstracts presented at the annual meetings of the Korean Radiological Society (KRS), and abstracts presented by Korean investigators at the annual meetings of the Radiological Society of North America (RSNA) and European Congress of Radiology (ECR) from 2001 to 2002 were searched for subsequent publication, using PubMed and the Korean Medical Database. The following variables were evaluated. 1) The overall publication rate; 2) the publication rates according to the radiological subspecialty, presentation type (oral or poster), sample size (≤ 20, 21 50, or > 50), study design (prospective or retrospective), statistical analysis (present or absent), and study outcome (positive or negative); 3) the time to publication; 4) the journal where the study was published; 5) consistency between the abstract and the final publication. Of 1,097 abstracts, 301 (27.4%) were subsequently published, at an average of 15.8 ± 13.8 months after presentation in 48 journals. The publication rates for studies presented at the RSNA (35.4%) and ECR (50.5%) conferences were significantly higher than that for the KRS conference (23.6%, p < 0.05). Vascular/interventional radiology studies had the highest publication rate (33.1%), whereas musculoskeletal radiology studies had the lowest publication rate (17.1%). Other factors associated with subsequent publication were prospective design, use of statistical testing, and a positive study outcome. The publication rate is significantly lower for the KRS (23.6%) meeting abstracts as compared to those of the RSNA (35.4%) and ECR (50.5%). Prospective design, use of statistical testing, and positive study outcome have a statistically significant effect on the publication rate

  15. Awareness-of-the-issues investigation about radiological technologist's operating discretionary authority etc

    International Nuclear Information System (INIS)

    Fukada, Teruaki

    2008-01-01

    The discretionary range of a radiological technologist and the autonomy on law were investigated by the questionnaire. The degree of satisfaction of work and the domain to lengthen were investigated. Result, the inspection direction change of MRI inspection and the urgent connection at the time of diagnostic imaging unusual discovery is discretion. However, there are no part change and addition of a general photography inspection at discretion. Explanation of the inspection result of a patient is also useless. Moreover, many of troubles are explanation relations, It was much between the doctor or the patient. For the degree of operating satisfactory, definite aim in life is 70 points. There were about 70 points about speciality nature. The degree of discretion has many less than 50 points. On the whole, a female radiological technologist's degree of satisfaction was low. Next, the autonomy of a radiological technologist method was low and many wished a legal revision. Specialization is promoted as a future measure. Diagnostic imaging field advance is lengthened. Improvement in a status of a radiological technologist, Activity fullness of the Japan Association of Radiological Technologists is expected. (author)

  16. Radiological investigation in the boiler's maintenance operations in a Coal-Fired power plant

    International Nuclear Information System (INIS)

    Robles, Beatriz; Mora, Juan C.; Cancio, David; Baeza, Antonio; Corbacho, Jose A.

    2008-01-01

    As part of a study being performed in the four biggest coal-fired power plants in Spain, the formation of scales of radioisotopes in parts of the heat recovery system was investigated. This effect should be more important in the case of 210 Po and 210 Pb. Thereby, it is likely in given specific chemical conditions that scales could be formed with a high concentration of 210 Pb, probably in secular equilibrium with 210 Po and 210 Bi. Those scales could reach activity concentrations of some hundreds of Bq g -1 . In order to study within the boiler this scale formation, an investigation during the maintenance operations programmed in the 'Compostilla' coal-fired power plant (Ponferrada-Spain) was carried out. Those operations are performed each 2-3 years and last for around 30 or 40 days. Measurements of ambient dose equivalent (H * (10)) in the boiler before and after the entrance of the operators, together with beta surface contamination on the bottom ashes attached in the walls and on the tubes, were performed. The last measurements were carried out for screening purposes in order to select those areas on the tubes which could present Po scales. Even if chemical conditions are in general oxidising within the boiler, since conditions are not homogeneous, some zones were localized in which surface contamination was measured. In these spots, samples were collected and then measured in the laboratory. Moreover, an analysis of maintenance tasks, used personal protection equipment, working times and other important parameters was also carried out. This analysis is important in order to perform radiological evaluations, as realistic as possible, of the effective doses that could be received by maintenance operators. In the present study, the values of the measurements performed and the results of the assessment of the effective doses for the workers are presented. (author)

  17. Residual radioactivity investigation and radiological assessments for self-disposal of concrete waste in nuclear fuel processing facility

    International Nuclear Information System (INIS)

    Seol, Jeung Gun; Ryu, Jae Bong; Cho, Suk Ju; Yoo, Sung Hyun; Song, Jung Ho; Baek, Hoon; Kim, Seong Hwan; Shin, Jin Seong; Park, Hyun Kyoun

    2007-01-01

    In this study, domestic regulatory requirement was investigated for self-disposal of concrete waste from nuclear fuel processing facility. And after self-disposal as landfill or recycling/reuse, the exposure dose was evaluated by RESRAD Ver. 6.3 and RESRAD BUILD Ver. 3.3 computing code for radiological assessments of the general public. Derived clearance level by the result of assessments for the exposure dose of the general public is 0.1071Bq/g (3.5% enriched uranium) for landfill and 0.05515 Bq/cm 2 (5% enriched uranium) for recycling/reuse respectively. Also, residual radioactivity of concrete waste after decontamination was investigated in this study. The result of surface activity is 0.01Bq/cm 2 for emitter and the result of radionuclide analysis for taken concrete samples from surface of concrete waste is 0.0297Bq/g for concentration of 238 U, below 2w/o for enrichment of 235 U and 0.0089Bq/g for artificial contamination of 238 U respectively. Therefore, radiological hazard of concrete waste by self-disposal as landfill and recycling/reuse is below clearance level to comply with clearance criterion provided for Notice No. 2001-30 of the MOST and Korea Atomic Energy Act

  18. Is the Internet a Suitable Patient Resource for Information on Common Radiological Investigations?: Radiology-Related Information on the Internet.

    Science.gov (United States)

    Bowden, Dermot J; Yap, Lee-Chien; Sheppard, Declan G

    2017-07-01

    This study aimed to assess the quality of Internet information about common radiological investigations. Four search engines (Google, Bing, Yahoo, and Duckduckgo) were searched using the terms "X-ray," "cat scan," "MRI," "ultrasound," and "pet scan." The first 10 webpage results returned for each search term were recorded, and their quality and readability were analyzed by two independent reviewers (DJB and LCY), with discrepancies resolved by consensus. Analysis of information quality was conducted using validated instruments for the assessment of health-care information (DISCERN score is a multi-domain tool for assessment of health-care information quality by health-care professionals and laypeople (max 80 points)) and readability (Flesch-Kincaid and SMOG or Simple Measure of Gobbledygook scores). The search result pages were further classified into categories as follows: commercial, academic (educational/institutional), and news/magazine. Several organizations offer website accreditation for health-care information, and accreditation is recognized by the presence of a hallmark or logo on the website. The presence of any valid accreditation marks on each website was recorded. Mean scores between groups were compared for significance using the Student t test. A total of 200 webpages returned (108 unique website addresses). The average DISCERN score was search engines. No significant difference was seen in readability between modalities or between search engines. Websites carrying validated accreditation marks were associated with higher average DISCERN scores: X-ray (39.36 vs 25.35), computed tomography (45.45 vs 31.33), and ultrasound (40.91 vs 27.62) (P information on the Internet is poor. High-quality online resources should be identified so that patients may avoid the use of poor-quality information derived from general search engine queries. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  19. Associations Between NIH Funding and Advanced Bibliometric Indices Among Radiological Investigators.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Jiang, Anthony

    2016-06-01

    Whereas data support the h index (reflecting both publications and citations) as an indicator of academic productivity, other advanced bibliometric indices aiming to address shortcomings of the h index remain poorly studied. Our objective was to compare the associations between bibliometric indices and total National Institutes of Health (NIH) grant funding among investigators within U.S. academic radiology departments. NIH grant funding amounts for 400 NIH-funded investigators within radiology departments were obtained from Blue Ridge Institute for Medical Research. Investigators' publications and associated citations were identified using Scopus. Indices computed for each investigator included: publication count, citation count, h index, i-10 index, hc index (h index adjusted for recency of publications), m quotient (h index adjusted for career duration), and e index and g index (both account for highly cited articles). Spearman correlations were performed between indices and funding. Multivariable linear regression was performed to identify significant independent predictors of funding. For MD investigators: the indices exhibited no-to-weak correlations with funding (r = 0.173-0.387); m quotient exhibited the largest correlation and was the only significant (albeit weak) independent predictor of funding (P = 0.011). For PhD investigators: correlation with funding was weak for m quotient (r = 0.323), although moderate for other indices (r = 0.518-0.568); publication count exhibited highest correlation; publication count (P < 0.001) and hc index (P = 0.024) were significant independent predictors of funding. Bibliometric indices were more strongly associated with grant funding for PhD than for MD radiology investigators, with publication count exhibiting the strongest association in the latter group. Time-weighted adjustments, as reflected by the m quotient and hc index, may improve efforts to predict funding using bibliometrics. Copyright

  20. Preliminary radiological assessments of near-surface low-level radioactive waste repositories

    International Nuclear Information System (INIS)

    Sumerling, T.J.; Nancarrow, D.J.

    1988-08-01

    This report summarises preliminary assessments of post-closure radiological impact of LLW repositories at four sites previously under investigation by UK Nirex Ltd. The objectives of the assessments were: to demonstrate a methodology for site specific assessments, to identify important information requirements for detailed assessments; to identify methodological and research requirements. Doses and risks due to groundwater pathways, human intrusion, gaseous release and natural environmental change are estimated. (author)

  1. Radiological monitoring plan for the Oak Ridge Y-12 Plant: Surface Water

    International Nuclear Information System (INIS)

    1997-10-01

    The Y-12 Plant conducts a surface water monitoring program in response to DOE Orders and state of Tennessee requirements under the National Pollutant Discharge Elimination System (NPDES). The anticipated codification of DOE Order 5400.5 for radiation protection of the public and the environment (10 CFR Part 834) will require an environmental radiation protection plan (ERPP). The NPDES permit issued by the state of Tennessee requires a radiological monitoring plan (RMP) for Y-12 Plant surface waters. In a May 4, 1995 memo, the state of Tennessee, Division of Water Pollution Control, stated their desired needs and goals regarding the content of RMPs, associated documentation, and data resulting from the RMPs required under the NPDES permitting system (L. Bunting, General Discussion, Radiological Monitoring Plans, Tennessee Division of Water Pollution Control, May 4,1995). Appendix A provides an overview of how the Y-12 Plant will begin to address these needs and goals. It provides a more complete, documented basis for the current Y-12 Plant surface water monitoring program and is intended to supplement documentation provided in the Annual Site Environmental Reports (ASERs), NPDES reports, Groundwater Quality Assessment Reports, and studies conducted under the Y-12 Plant Environmental Restoration (ER) Program. The purpose of this update to the Y-12 Plant RMP is to satisfy the requirements of the current NPDES permit, DOE Order 5400.5, and 10 CFR Part 834, as current proposed, by defining the radiological monitoring plan for surface water for the Y-12 Plant. This plan includes initial storm water monitoring and data analysis. Related activities such as sanitary sewer and sediment monitoring are also summarized. The plan discusses monitoring goals necessary to determine background concentrations of radionuclides, to quantify releases, determine trends, satisfy regulatory requirements, support consequence assessments, and meet requirements that releases be ''as low as

  2. Investigation of surface roughness on etched glass surfaces

    International Nuclear Information System (INIS)

    Papa, Z.; Budai, J.; Farkas, B.; Toth, Z.

    2011-01-01

    Roughening the surface of solar cells is a common practice within the photovoltaic industry as it reduces reflectance, and thus enhances the performance of devices. In this work the relationship between reflectance characterized by the haze parameter, surface roughness and optical properties was investigated. To achieve this goal, model samples were prepared by hydrofluoric acid etching of glass for various times and measured by optical microscopy, spectroscopic ellipsometry, scanning electron microscopy, and atomic force microscopy. Our investigation showed that the surface reflectance was decreased not only by the roughening of the surface but also by the modification of the depth profile and lowering of the refractive index of the surface domain of the samples.

  3. Radiological assessment of surface water quality around proposed uranium mining site in India.

    Science.gov (United States)

    Jha, S K; Lenka, P; Gothankar, S; Tripathi, R M; Puranik, V D; Khating, D T

    2009-06-01

    The gross alpha and gross beta activities were estimated for radiological assessment of surface water quality around the proposed uranium mining site Kylleng Pyndengsohiong Mawthabah (Domiasiat), West Khasi Hills District, Meghalaya situated in a high rainfall area (12,000mm) in India. 189 Surface water samples were collected over different seasons of the year from nine different locations covering around 100km(2). Gross beta activities were found to vary from 144 to 361mBq/L which is much below the prescribed WHO limit of 1000mBq/L for drinking water. Gross alpha activities varied from 61 to 127mBq/L. These values are much below the reported gross alpha values by other countries. In about 7% of the samples the alpha activities remain exceeded the WHO guideline limit of 100mBq/L. Surface water samples collected during the summer season of the year show higher activity whereas low activity was found from samples collected during monsoon season. Results show that all water sources are acceptable as drinking water for human consumption from the radiological point of view, the higher gross alpha concentrations in a few locations remains so only for short duration during the summer season.

  4. Radiological assessment of surface water quality around proposed uranium mining site in India

    International Nuclear Information System (INIS)

    Jha, S.K.; Lenka, P.; Gothankar, S.; Tripathi, R.M.; Puranik, V.D.; Khating, D.T.

    2009-01-01

    The gross alpha and gross beta activities were estimated for radiological assessment of surface water quality around the proposed uranium mining site Kylleng Pyndengsohiong Mawthabah (Domiasiat), West Khasi Hills District, Meghalaya situated in a high rainfall area (12,000 mm) in India. 189 Surface water samples were collected over different seasons of the year from nine different locations covering around 100 km 2 . Gross beta activities were found to vary from 144 to 361 mBq/L which is much below the prescribed WHO limit of 1000 mBq/L for drinking water. Gross alpha activities varied from 61 to 127 mBq/L. These values are much below the reported gross alpha values by other countries. In about 7% of the samples the alpha activities remain exceeded the WHO guideline limit of 100 mBq/L. Surface water samples collected during the summer season of the year show higher activity whereas low activity was found from samples collected during monsoon season. Results show that all water sources are acceptable as drinking water for human consumption from the radiological point of view, the higher gross alpha concentrations in a few locations remains so only for short duration during the summer season.

  5. Introduction to CRRIS: a computerized radiological risk investigation system for assessing atmospheric releases of radionuclides

    International Nuclear Information System (INIS)

    Baes, C.F. III; Miller, C.W.; Kocher, D.C.; Sjoreen, A.L.; Murphy, B.D.

    1985-08-01

    The CRRIS is a Computerized Radiological Risk Investigation System consisting of eight fully integrated computer codes which calculate environmental transport of atmospheric releases of radionuclides and resulting doses and health risks to individuals or populations. Each code may also be used alone for various assessment applications. Radionuclides are handled by the CRRIS either in terms of the released radionuclides or the exposure radionuclides which consist of both the released nuclides and decay products that grow in during environmental transport. The CRRIS is not designed to simulate short-term effects. 51 refs

  6. Radiological impact of surface water and sediment near uranium mining sites.

    Science.gov (United States)

    Ivanova, K; Stojanovska, Z; Badulin, V; Kunovska, B; Yovcheva, M

    2015-12-01

    The aim of this study is to assess the radiological impact of surface water and sediment around uranium mining sites 20 years after their closing. The areas under observations are 31 former classical underground uranium mining and exploratory sites in Bulgaria, named as objects. The extraction and processing of uranium ores in the Republic of Bulgaria were ended in 1992. To assess the radiological impact of radionuclides field expeditions were performed to sample water and bottom sediment. The migration of uranium through surface water was examined as one of the major pathways for contamination spread. The range of uranium concentration in water flowing from the mining sites was from 0.012 to 6.8 mgU l(-1) with a geometric mean of 0.192 mgU l(-1). The uranium concentrations in water downstream the mining sites were approximately 3 times higher than the background value (upstream). The concentrations of Unat, (226)Ra, (210)Pb, and (232)Th in the sediment of downstream river were higher than those upstream by 3.4, 2.6, 2, and 1.7 times, respectively. The distribution coefficient of uranium reflects its high mobility in most of the sites. In order to evaluate the impact on people as well as site prioritization for more detailed assessment and water management, screening dose assessments were done.

  7. Radiological monitoring plan for the Oak Ridge Y-12 Plant: Surface water

    International Nuclear Information System (INIS)

    1995-01-01

    National Pollutant Discharge Elimination System (NPDES) Permit TN0002968, issued April 28, 1995, requires that the Y-12 Plant Radiological Monitoring Plan for surface water be modified (Part 111-H). These modifications shall consist of expanding the plan to include storm water monitoring and an assessment of alpha, beta, and gamma emitters. In addition, a meeting was held with personnel from the Tennessee Department of Environment and Conservation (TDEC) on May 4, 1995. In this meeting, TDEC personnel provided guidance to Y-12 Plant personnel in regard to the contents of the modified plan. This report contains a revised plan incorporating the permit requirements and guidance provided by TDEC personnel. In addition, modifications were made to address future requirements of the new regulation for radiation protection of the public and the environment in regards to surface water monitoring

  8. Investigation of possible methods for equipment self-tests in digital radiology

    International Nuclear Information System (INIS)

    Zoetelief, J.; Idris, H. H. E.; Jansen, J. T. M.

    2005-01-01

    Quality control in digital radiology can be time-consuming. Equipment self-tests may significantly decrease staff workload. The two most essential parameters for radiology systems are image quality and patient dose. Concerning patient dose, information on the dose-area product (DAP) values generally forms the basis for assessment of patient dose. DAP-values can be measured using a transmission ionisation chamber or calculated from equipment settings. In the present study, various image quality parameters were derived using a contrast-detail (C-D) phantom. The investigation included a computer-aided assessment of C-D images, which produced various parameters, and also parameters based upon scoring by human observers. In addition, another parameter was calculated from modulation transfer function (MTF) measurements. The automatically calculated parameters showed good correlation with human readings, although the number of X-ray systems studied is still limited. We propose a combined evaluation of DAP and automatically calculated C-D or MTF parameters for equipment self-tests. (authors)

  9. Investigation of radiological emergencies by the IPEN-CNEN/SP during the years 2001 to 2010

    International Nuclear Information System (INIS)

    Suzuki, Fabio Fumio; Mitake, Malvina Boni

    2011-01-01

    The Brazilian National Nuclear Energy Commission maintain, in each of its unities, a technical team for investigation and initial response to radiological and nuclear emergency situations which can occur outside of its installations. At the Sao Paulo state, Brazil, that task is accomplished by the Radioprotection Management (GRP) of the Instituto de Pesquisas Energeticas e Nucleares, IPEN-CNEN/SP, Brazil. This paper shows the results obtained by the GRP, analysing which entities action the system, the nature of the event, the involved type of radiation source and the geographical distribution of occurrences in the state. During the period between 2001 and 2010, the GRP attended to 98 notifications, and the entity which the most action the system was the Fire Department. The radionuclide of most incidence was the Am-241, mainly because of radioactive lightning-arrester, followed of radionuclides used in nuclear medicine such as Mo-99/Tc-99m and I-131

  10. The development of a surface hydrology model for use in radiological safety assessments

    International Nuclear Information System (INIS)

    Little, R.H.; Ashton, J.

    1991-01-01

    A detailed understanding and quantification of geosphere and biosphere water movements is vital when assessing the impact of a radioactive waste repository. Not only is water important in the transport of radionuclides from the repository into the geosphere and hence into the biosphere, but it is also important in the transport of radionuclides within the biosphere and their transport to humans. Although geosphere water fluxes have traditionally been rigorously quantified, the quantification of biosphere water fluxes has been far less rigorous. In order to redress the balance, Associated Nuclear Services Ltd (ANS) have proposed to develop a surface hydrology model for use within radiological assessments undertaken by Her Majesty's Inspectorate of Pollution (HMIP) of the United Kingdom Department of the Environment (UKDoE). It is proposed that the deterministic, lumped, quasi-physical/semi-empirical approach of conceptual models should be adopted for the model. The model will be sufficiently flexible to be applicable to a wide range of catchments, as well as a variety of temporal and spatial scales. It is envisaged that the model will have a variety of uses within the HMIP assessment methodology including the identification of significant surface hydrological processes, the provision of input data for assessment codes and the study of the biosphere-geosphere interface. (17 refs., 4 figs.)

  11. Experimental investigations of radiological and nuclear functional diagnosis of the ureter

    International Nuclear Information System (INIS)

    Wolf, M.

    1980-01-01

    A new nuclear method for reflux and motility investigations of the ureter is described, and its diagnostic potential is determined in model experiments. Thresholds of visualisation of a urine spindle are considered. The following results were obtained in animal experiments: 1) If investigations are repeated under identical conditions, there are considerable variations of refluxivity. 2) With IMCU (Isotope Micturition Cystoureterogram), the number of refluxes detected is about the same as with MCU (Micturition Cystoureterogram); this applies in particular to refluxes of the 3rd and 4th degree. 3) UKG is equal to AUR in judging the direction, time, velocity and frequency of discharge of a spindle while thickness and initial conus lenght of a spindle are better seen in AUR. 4) Inconstant depots of residual urine can be detected by UKG an AUR alike. The radiological observations made in the animal experiment are compared with the relevant literature, and possible error sources in the evaluation are indicated. Finally, the application of IMCU and UKG in humans is described. IMCU is recommended especially for pardiatric applications as the observation time is long and radiation exposure low. In renal function studies, the UKG supplies extensive information on functional data of the ureter which until now could be obtained only with the aid of contrast media. (orig./MG) [de

  12. Which radiological investigations should be performed to identify fractures in suspected child abuse?

    International Nuclear Information System (INIS)

    Kemp, A.M.; Butler, A.; Morris, S.; Mann, M.; Kemp, K.W.; Rolfe, K.; Sibert, J.R.; Maguire, S.

    2006-01-01

    Aims: To determine which radiological investigations should be performed and which children should be investigated. Materials and methods: An all language literature search of original articles; from 1950-October 2005. Two reviewers independently reviewed each article. A third was carried out on disagreement. Each study was assessed using standardised data extraction, critical appraisal and evidence forms. Results: Thirty-four studies were included. Fifteen addressed the question: which investigation has a higher yield, skeletal surveys (SS) or bone scintigraphy (BS)? Studies gave conflicting results. Overall neither investigation is as good as the two combined. BS predominately missed skull, metaphyseal and epiphyseal fractures, whereas SS commonly missed rib fractures. Two studies showed that a repeat SS 2 weeks after the initial study provided significant additional information about tentative findings, the number and age of fractures. A comparative study evaluated additional oblique views of ribs in 73 children and showed improved diagnostic sensitivity, specificity and accuracy. Four studies addressed the diagnostic yield for occult fractures with respect to age. This was significant for children under 2-years old. Conclusions: In children under 2-years old, where physical abuse is suspected, diagnostic imaging of the skeleton should be mandatory. SS or BS alone is inadequate to identify all fractures. It is recommended that all SS should include oblique views of the ribs. This review suggests that the following options would optimize the diagnostic yield. However, each needs to be evaluated prospectively: SS that includes oblique views, SS and BS, a SS with repeat SS or selected images 2 weeks later or a BS plus skull radiography and coned views of metaphyses and epiphyses

  13. Which radiological investigations should be performed to identify fractures in suspected child abuse?

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, A.M.; Butler, A.; Morris, S.; Mann, M.; Kemp, K.W.; Rolfe, K.; Sibert, J.R.; Maguire, S

    2006-09-15

    Aims: To determine which radiological investigations should be performed and which children should be investigated. Materials and methods: An all language literature search of original articles; from 1950-October 2005. Two reviewers independently reviewed each article. A third was carried out on disagreement. Each study was assessed using standardised data extraction, critical appraisal and evidence forms. Results: Thirty-four studies were included. Fifteen addressed the question: which investigation has a higher yield, skeletal surveys (SS) or bone scintigraphy (BS)? Studies gave conflicting results. Overall neither investigation is as good as the two combined. BS predominately missed skull, metaphyseal and epiphyseal fractures, whereas SS commonly missed rib fractures. Two studies showed that a repeat SS 2 weeks after the initial study provided significant additional information about tentative findings, the number and age of fractures. A comparative study evaluated additional oblique views of ribs in 73 children and showed improved diagnostic sensitivity, specificity and accuracy. Four studies addressed the diagnostic yield for occult fractures with respect to age. This was significant for children under 2-years old. Conclusions: In children under 2-years old, where physical abuse is suspected, diagnostic imaging of the skeleton should be mandatory. SS or BS alone is inadequate to identify all fractures. It is recommended that all SS should include oblique views of the ribs. This review suggests that the following options would optimize the diagnostic yield. However, each needs to be evaluated prospectively: SS that includes oblique views, SS and BS, a SS with repeat SS or selected images 2 weeks later or a BS plus skull radiography and coned views of metaphyses and epiphyses.

  14. Investigation of innovative radiation imaging method and system for radiological environments

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, H. [School of Biomedical Engineering, Korea University, Seoul (Korea, Republic of); Joung, J., E-mail: jinhun.joung@nucaremed.com [School of Biomedical Engineering, Korea University, Seoul (Korea, Republic of); Nucare, Inc., Incheon (Korea, Republic of); Kim, Y. [School of Biomedical Engineering, Korea University, Seoul (Korea, Republic of); Nucare, Inc., Incheon (Korea, Republic of); Lee, K. [School of Biomedical Engineering, Korea University, Seoul (Korea, Republic of)

    2017-03-01

    We have developed a novel imaging method that can be applied to most applications in the field of radiological environment imaging. It resolves either two-dimensional (2D) or three-dimensional (3D) distributions of radioactive sources in applications for homeland security, environmental monitoring, radiation contamination monitoring, baggage inspection, nuclear power plant monitoring, and more. The proposed imaging method uses a simple detector configured as a radiation-counting detector with spectroscopic capabilities. The detector module consists of two components: a flat field-of-view (FOV) collimator with a 30° FOV opening and a typical single-channel radiation detector made of a 2 in.×2 in. NaI(Tl) scintillator coupled to a 2 in photomultiplier tube (PMT). This simple detector module makes it possible to develop a cost-effective imaging system and provide design freedom in extending the system configuration to include one-dimensional (1D) or 2D detector-array shapes to meet the needs of various applications. One of most distinctive features of the new imaging method is that it uses only a pair of 2D projections to obtain a 3D reconstruction. The projections are measured by the proposed detector module at two positions orthogonal to one another; the measured projections are manipulated to enhance the resolution of the reconstructed 3D image. The imaging method comprises several steps performed consecutively: projection measurement, energy re-binning, projection separation, resolution and attenuation recovery, image reconstruction, and image consolidation and quantitative analysis. The resolution and attenuation recovery step provides the most distinctive and important processing by which the poor quality of projection data is enhanced. Such poor quality is mainly due to the use of a simple detector with a wide-opening flat FOV collimator. Simulation and experimental studies have been conducted to validate the proposed method. In this investigation, we

  15. Ten years investigation on radiological exposures to the embryo and fetus in pregnant women of Iran

    International Nuclear Information System (INIS)

    Arbabi, A.

    2001-01-01

    Over 1340 Iranian pregnant patients, exposed to diagnostic x-rays during 1984 to 1994, referred to me for investigation and estimation of the absorbed dose to their embryo or fetus. They were almost all the patients exposed to x-rays in the whole country in 10 years. Two sets of questionnaires were filed for each patient and all the exposing condition and setting information obtained from the radiology centers concerned. The absorbed dose to embryo or fetus accurately calculated and in some cases measured in a phantom for each patient. The youngest patient at the time of irradiation was 15 and the oldest was 51 with an average of 28.624±5.961 years old. The AP and lateral thickness of patient's abdomen on average were 18.078±0.162 cm and 24.630±8.365 cm respectively. The average weight of patients was 59.285±12.945 kg. ranging from 30 kg to 122 kg. The marriage age of the patients on average was 19.398±4.107 years ranging from 9 to 42 years old. The average age of fetus when exposed to x-rays was 31.22±18.76 days. About 20% of the patients had exposures in 2 to 4 more sessions. The average fetal dose was 0.68±0.381 cGy with over 37% from 1 to 9 cGy. (author)

  16. Radiological and anatomical investigation of calcific tendinitis of the gluteus maximus tendon

    Energy Technology Data Exchange (ETDEWEB)

    Karakida, Osamu; Aoki, Jun; Fujioka, Fumio; Watanabe, Tomofumi; Seo, Gwy-Suk; Sone, Shusuke; Nagata, Tetsuji [Shinshu Univ., Matsumoto, Nagano (Japan). Faculty of Medicine

    1995-06-01

    The radiological findings in four cases of gluteus maximus tendinitis were retrospectively analyzed. All the patients underwent radiographic, CT and MRI examinations. Amorphous or round calcifications were detected on lateral radiographs in three cases, and on CT in all cases. A small cortical erosion was observed in three cases on both radiographs and CT. MRI showed a thickened gluteus maximus tendon, but no other specific features. In the supine position, which is common in routine CT and MRI studies, the calcific deposits appeared to be distributed along the vastus lateralis muscle tendon. To correlate these radiographic observations with the topographic anatomy of the tendon`s insertion, we investigated 14 thighs of seven cadavers, and clarified that the tendon`s insertion was the main component of the lateral femoral intermuscular septum. Consequently we performed MRI on a volunteer in a prone position who was asked to maintain contraction of the gluteus maximus and quadratus femoris muscles. The images obtained showed clearly that the gluteus maximus tendon was directed dorsally. In conclusion, radiography and CT are the modalities of choice for diagnosis of this entity. Additionally, radiologists should be aware that the gluteus maximus tendons are directed laterally as a main part of the lateral femoral intermuscular septum on routine CT and MRI. (author).

  17. Radiologic investigation of apert syndrome (acrocephalosyndactyly type 1) -a case report-

    International Nuclear Information System (INIS)

    Lee, Yeon Hee; Cho, Whi Youl; Kim, Myung Soon; Hong, In Soo; Sung, Ki Joon; Yang, Jae Seung

    1991-01-01

    Apert syndrome (Acrocephalosyndactyly type 1) is a rare congenital anomaly characterized by craniosynosis and symmetric-syndactyly of both extremities. Radiological examination of the skull shows hydrocephalus due to aqueductal stenosis. In the facial bones, the hypoplastic maxilla and relatively prominent mandible are observed associated with other anomalies such as cleft palate. Radiologic examination of both hands and feet show bony or subcutaneous syndactylism and typical mitten hands and webbed toes

  18. Predicting diagnostic error in radiology via eye-tracking and image analytics: Preliminary investigation in mammography

    International Nuclear Information System (INIS)

    Voisin, Sophie; Tourassi, Georgia D.; Pinto, Frank; Morin-Ducote, Garnetta; Hudson, Kathleen B.

    2013-01-01

    Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists’ gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels.Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from four Radiology residents and two breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADS images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated.Results: Machine learning can be used to predict diagnostic error by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model [area under the ROC curve (AUC) = 0.792 ± 0.030]. Personalized user modeling was far more accurate for the more experienced readers (AUC = 0.837 ± 0.029) than for the less experienced ones (AUC = 0.667 ± 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features.Conclusions: Diagnostic errors in mammography can be predicted to a good extent by leveraging the radiologists’ gaze behavior and image content

  19. Predicting diagnostic error in radiology via eye-tracking and image analytics: Preliminary investigation in mammography

    Energy Technology Data Exchange (ETDEWEB)

    Voisin, Sophie; Tourassi, Georgia D. [Biomedical Science and Engineering Center, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Pinto, Frank [School of Engineering, Science, and Technology, Virginia State University, Petersburg, Virginia 23806 (United States); Morin-Ducote, Garnetta; Hudson, Kathleen B. [Department of Radiology, University of Tennessee Medical Center at Knoxville, Knoxville, Tennessee 37920 (United States)

    2013-10-15

    Purpose: The primary aim of the present study was to test the feasibility of predicting diagnostic errors in mammography by merging radiologists’ gaze behavior and image characteristics. A secondary aim was to investigate group-based and personalized predictive models for radiologists of variable experience levels.Methods: The study was performed for the clinical task of assessing the likelihood of malignancy of mammographic masses. Eye-tracking data and diagnostic decisions for 40 cases were acquired from four Radiology residents and two breast imaging experts as part of an IRB-approved pilot study. Gaze behavior features were extracted from the eye-tracking data. Computer-generated and BIRADS images features were extracted from the images. Finally, machine learning algorithms were used to merge gaze and image features for predicting human error. Feature selection was thoroughly explored to determine the relative contribution of the various features. Group-based and personalized user modeling was also investigated.Results: Machine learning can be used to predict diagnostic error by merging gaze behavior characteristics from the radiologist and textural characteristics from the image under review. Leveraging data collected from multiple readers produced a reasonable group model [area under the ROC curve (AUC) = 0.792 ± 0.030]. Personalized user modeling was far more accurate for the more experienced readers (AUC = 0.837 ± 0.029) than for the less experienced ones (AUC = 0.667 ± 0.099). The best performing group-based and personalized predictive models involved combinations of both gaze and image features.Conclusions: Diagnostic errors in mammography can be predicted to a good extent by leveraging the radiologists’ gaze behavior and image content.

  20. Development of a scintillating fiber-optic dosimeter for measuring the entrance surface dose in diagnostic radiology

    International Nuclear Information System (INIS)

    Yoo, Wook Jae; Jeon, Dayeong; Seo, Jeong Ki; Shin, Sang Hun; Han, Ki-Tek; Youn, Won Sik; Cho, Seunghyun; Lee, Bongsoo

    2013-01-01

    As a direct method, a scintillating fiber-optic dosimeter (SFOD) was fabricated using an organic scintillator, a plastic optical fiber, and a photomultiplier tube (PMT) to measure entrance surface doses (ESDs) in diagnostic radiology. In this study, we measured the scintillating lights, which are altered by to the exposure parameters, such as the tube potential, current-time product, and focus-surface distance (FSD), with an SFOD placed on the top of an acrylic and aluminum chest phantom to provide a backscatter medium. The scintillating light signals of the SFOD were compared with the ESDs obtained using conventional dosimeters. The ESDs that were measured using the dose-area product (DAP) meter, as an indirect method, and a semiconductor dosimeter, as a direct method, were distinguished according to differences in the measurement position and the method used. In the case of the two direct methods with the SFOD and the semiconductor dosimeter, the output light signals of the SFOD were similar to the ESDs of the semiconductor dosimeter. It is expected that the SFOD will be a useful dosimeter for diagnostic radiology due to its many advantages, including its small size, lightweight, substantial flexibility, remote sensing, real-time monitoring, and immunity to electromagnetic interference (EMI). - Highlights: ► Fabrication of a scintillating fiber-optic dosimeter for use in diagnostic radiology. ► Measurements of the scintillating light according to the exposure parameters. ► Comparison of the entrance surface doses obtained using conventional dosimeters

  1. Radiological investigation of renovascular hypertension from IVU to digital subtraction angiography. A critical evaluation

    International Nuclear Information System (INIS)

    Amiel, M.; Froment, A.; Pinet, F.; Huguet, M.

    1986-01-01

    For the last 20 years, the value of radiology in renovascular hypertension (RVH) is well established from diagnostic and therapeutic points of view. However things are changing now due to a better appraisal of the incidence of RVH, new antihypertensive drugs, and new radiological procedures (digital angiography, percutaneous transluminal angioplasty). The approach now takes in account the mode of imaging for a better evaluation of the renal artery stenosis and costs of the proceedings as well. Finally a new strategy has been set up for RVH patients management [fr

  2. An investigation on clinical, radiological and biochemical methods for assessing periodontitis activity

    International Nuclear Information System (INIS)

    Janssen, P.T.M.

    1987-01-01

    In order to recognize in which stage rapidly progressing destruction of periodontal ligament fibers occurs, a number of diagnostic methods are studied in this thesis. It turns out that the actual much utilized clinical methods can not be improved while radiological and biochemical diagnositic methods are much more promising. 106 refs.; 20 figs.; 36 tabs

  3. Socio-economic and other non-radiological impacts of the near surface disposal of radioactive waste

    International Nuclear Information System (INIS)

    2002-09-01

    The objective of this report is to introduce, in a generic sense, the elements that could comprise a socio-economic and non-radiological environmental impact assessment. The various social, economic and environmental impacts that could be associated with surface and near surface disposal are discussed through factors that could apply at the local, regional or national level. Impact management is also discussed. The report also introduces concepts to help Member States develop their own approaches to undertaking impact assessment and management. The report is intended to complement IAEA documents on the technology and safety aspects of the near surface disposal of radioactive waste. The scope of this report includes a discussion of a range of social, economic and nonradiological environmental impacts relevant to surface and near surface disposal and illustrations of some impact management measures

  4. Investigation of surface and underground waters about the Blayais nuclear site - 2010

    International Nuclear Information System (INIS)

    Migeon, A.; Bernollin, A.; Dunand, E.; Barbey, P.; Boilley, D.; Josset, M.

    2011-01-01

    This investigation aims at proposing a first assessment of the impact of releases on surface and underground waters around the Blayais nuclear power station, i.e. the assessment of the (mainly radiological) quality of waters. The report identifies the various pollution sources: old sources (like atmospheric nuclear tests, nuclear accidents), incidents in the Blayais station, and potential sources for the present contamination. Different radionuclides are searched like tritium, carbon 14, gamma radioactivity (from different elements), some beta emitters, radon as well as some chemicals related to the station activity (hydrazine, boric acid, EDTA, lithium, morpholine). Sampling sites are presented (estuary, canals, reservoirs). Radiological and chemical analysis are reported and commented. Significant presence of Tritium and Nickel-63 are noticed

  5. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P thermoluminescent dosemeter and its applications in diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Fung, K.K.L

    2000-12-01

    The recent introduction and development of the thermoluminescent (T.L.) phosphor material LiF:Mg,Cu,P (usually named TLD100H or GR200A) has aroused intense interest of scientists in the field of radiation dosimetry due to its very favourable dosimetric characteristics. Both conventional LiF:Mg,Ti (TLD100) and LiF:Mg,Cu,P T.L. phosphors are tissue-equivalent but GR200A outperforms in respect of its very much higher sensitivity, by a factor of greater than 25, and a dose detection threshold of less than 1 {mu}Gy. A reproducible readout and annealing regime was developed in the initial part of this study with the newly installed automatic TLD (Thermoluminescence Dosimetry) apparatus in the X-ray and Radiation Physics Laboratories of the Hong Kong Polytechnic University. Basic dosimetric characteristics of this T.L. dosemeter (supplied by Harshaw-Bicron Co.) were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. Dosimetric characteristics which included linearity, reproducibility, batch uniformity, energy response, and minimum detectable dose were studied using X-rays in the commonly used diagnostic radiology energy range. Favourable dosimetric characteristics were observed from this T.L. phosphor, which agrees well with published studies. The effect of the number of thermal treatment cycles in the initialisation process on dosimetric properties of this T.L. phosphor was also investigated. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom using facilities both in these laboratories and also in radiology departments of various district hospitals in Hong Kong. Radiation absorbed dose from the direct or scattered beam, at critical sites inside and on the surface of the phantom, were measured in these radiological studies. The special focus in some of these studies was to

  6. Radiological optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.

    1998-01-01

    Radiological optimization is one of the basic principles in each radiation-protection system and it is a basic requirement in the safety standards for radiation protection in the European Communities. The objectives of the research, performed in this field at the Belgian Nuclear Research Centre SCK-CEN, are: (1) to implement the ALARA principles in activities with radiological consequences; (2) to develop methodologies for optimization techniques in decision-aiding; (3) to optimize radiological assessment models by validation and intercomparison; (4) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (5) to develop methods and programmes to assist decision-makers during a nuclear emergency; (6) to support the policy of radioactive waste management authorities in the field of radiation protection; (7) to investigate existing software programmes in the domain of multi criteria analysis. The main achievements for 1997 are given

  7. Investigation of whether various types of radioactive waste are equivalent in terms of the radiological impact associated with their disposal

    International Nuclear Information System (INIS)

    Fearn, H.S.; Smith, G.M.; Davis, J.P.; Hill, M.D.

    1989-01-01

    The aim of this study is to investigate the possibility that various types of waste are equivalent in terms of the risks associated with their disposal in so far as they are viewed by different sections of society. If such a framework can be established it could be used as an aid to decisions as to whether central disposal facilities, to accept waste from several countries, should be constructed. Details are presented of assumed radionuclide inventories for a representative range of radioactive wastes, calculations and results of the radiological impacts of their disposal, and illustrative methods for weighting the various components of impact which when summed provide an overall measure of impact. Five sets of weighting factors have been devised which are intended to represent the views of a) the radiological protection community, b) those with a pro-nuclear industry view, c) those who oppose nuclear power on safety grounds, d) the inhabitants of the country receiving wastes for disposal, and e) the inhabitants of the country dispatching wastes. On the basis of the calculated weighted radiological impacts it is demonstrated how conclusions can be drawn about general views on the disposal of each waste, about likely attitudes to the export of wastes from one country for disposal in another, and attitudes to exchanging wastes between countries. The study is preliminary and of limited scope. However, the results show that the general methodology is practicable and could be applied in a wider ranging investigation

  8. Radiological tracking down of pulmonary tuberculosis in France; Investigation concerning 984 declared cases

    International Nuclear Information System (INIS)

    Hirsch, A.; Le Gales, C.; Lefaure, C.; Vallier, F.

    1987-01-01

    The purpose of this study is to: describe the populations with a pulmonary tuberculosis risk factor, determine the percentage of cases observed by systematic tracking down in a declared tubercular population, compare the populations effectively covered by radiological tracking down to the populations with risk a factor, and compare the medical characteristics (symptomatology and the bacteriological expectoration results) of pulmonary tuberculosis cases discovered by systematic tracking down to the characteristics of cases discovered during hospital consultations or by personal doctors

  9. Investigation of ion diffusion towards plasmonic surfaces

    International Nuclear Information System (INIS)

    Gmucova, K.; Nadazdy, V.; Vojtko, A.; Majkova, E.; Kotlar, M.

    2013-01-01

    Plasmonic sensors have recently attracted much attention. The past few decades have seen a massive and continued interest in studying electrochemical processes at artificially structured electrodes. Such electrochemical sensors provide sensitive, selective, and easy to use approaches to the detection of many chemical species, e.g. environmental pollutants, biomolecules, drugs etc. The issue raised in this paper is to study the kinetic of the diffusion towards plasmonic surfaces in dark and under illumination with white LED diode. The possibility to use anomalous charge transfer towards plasmonic surfaces in electrochemical sensorics will be discussed, too. (authors)

  10. Thermodynamic investigation of surface of minerals

    Energy Technology Data Exchange (ETDEWEB)

    Medout-Marere, V.; Zoungrana, T.; Douillard, J.M.; Partyka, S. [U.P.R.E.S.A., 5072 CNRS, University of Montpellier II, place Eugene Bataillon, Case 015, 34095 Montpellier Cedex (France); Malandrini, H. [Sanofi Recherche-Centre de Recherches, 371 rue du Professeur Blayac, 34000 Montpellier (France)

    1998-06-06

    In this paper values of surface enthalpies and surface Gibbs free energies are given in order to characterize subsurface minerals. These values are obtained by combining standard measurements of adsorption and the Van Oss-Chaudhury-Good model [Van Oss, C.J., Chaudhury, M.K., Good, R.J., 1987. Monopolar surfaces. Adv. Coll. Interface Sci. 28, 35; Van Oss, C.J., Good, R.J., Chaudhury, M.K., 1988. Additive and nonadditive surface tension components and the interpretation of contact angles. Langmuir 4, 884; Van Oss, C.J., Giese, R.F., Costanzo, P.M., 1990. DLVO and non-DLVO interactions in hectorite. Clays Clay Min. 38, 151; Van Oss, C.J., Giese, R.F., Li, Z., Murphy, K., Norris, J., Chaudhury, M.K., Good, R.J., 1992. Determination of contact angles and pore sizes of porous media by column and thin layer wicking. J. Adhesion Sci. Technol. 6, 413.]. This model is reviewed and modified with a view to identify the types of interactions at solid-fluid interfaces and interpreting experimental results

  11. [Measurement of effective energy and entrance surface dose using fluorescent glass dosimeter in interventional radiology procedures: make of half-value layer measurement instrument and IVR-phantom].

    Science.gov (United States)

    Iida, Hiroji; Noto, Kimiya; Takata, Tadanori; Chabatake, Mitsuhiro; Yamamoto, Tomoyuki

    2010-05-20

    In interventional radiology (IVR) procedures, automatic brightness control (ABC) is helpful in maintaining good image quality by adjusting kV and/or mA based on the subject's thickness. However, it was difficult to measure effective energy using half-value layer (HVL). We investigated the usefulness of measuring effective energy and entrance surface dose using a fluorescent glass dosimeter in IVR procedures, and we made an HVL folder and IVR-phantom for that purpose. Effective energy measured using the HVL folder correlated well with reference ionization dosimeter (y=0.992x, r=0.963). The result indicated that the present method using an HVL folder and IVR-phantom provides accurate measurements of effective energy and entrance surface dose in IVR procedures. In conclusion, the present measurement method may be useful for quality control of IVR equipment. In addition, the development of this measurement technique may be useful for comparisons of exposure levels in different hospitals.

  12. Imaging the neonate in the incubator: an investigation of the technical, radiological and nursing issues.

    Science.gov (United States)

    Mutch, S J; Wentworth, S D P

    2007-11-01

    Modern neonatal incubators incorporate an X-ray tray device into the mattress support structure to facilitate patient examination with minimal disturbance and distress. However, the usual method of examination is to place the image plate directly underneath the baby. Users often cite radiological reasons for not using X-ray trays but modern quantitative evidence is lacking. This work looks at the technical and clinical aspects of imaging neonates in incubators and the impact that these may have in determining the imaging protocol. A number of hospitals were surveyed to determine their current method of examination and the reasons for their preference. Experimental measurements of the radiological impact of using (or not using) the X-ray tray were performed for a range of neonatal incubators. The average dose to the image plate was 5.9 microGy (range 5.4-6.4 microGy) for the "plate on mattress" method and 3.0 microGy (2.0-3.8 microGy) when using the tray--a 49% reduction owing to the mattress support materials. However, when using a computed radiography (CR) imaging system, the image quality differences were marginal. Survey results indicated that nurses preferred to use the tray but that radiographers were reluctant. We conclude that incubator manufacturers could do much to improve the radiological performance of their equipment and we offer recommendations. We also conclude that, with appropriate nurse and radiographer training and the advent of CR imaging systems, use of X-ray tray facilities may optimize imaging of the neonate in the incubator.

  13. An experimental investigation on reduced radiological penumbra for intermediate energy x-rays: Implications for small field radiosurgery

    Science.gov (United States)

    Keller, Brian Michael

    Current day external beam radiation therapy typically uses x-ray energies in the megavoltage (6--18 MV) or in the superficial/orthovoltage (80--350 kVp) energy ranges. It has been found that intermediate energy x-rays (those greater than orthovoltage but sub-megavoltage) may offer an advantage in the field of high precision radiation therapy such as in radiosurgery. This advantage is a reduction in the radiological penumbra associated with small (less than about 3 cm) radiation dose fields. A consequence of reduced radiological penumbra is a more homogenous, conformal dose distribution in the patient with dose escalation and organ sparing made more feasible. The objectives of this thesis were as follows: to produce and to characterize an intermediate energy x-ray beam, to establish a method of accurate penumbra measurement at the micron level for millimeter size fields, to measure the radiological penumbra of single small intermediate energy x-ray fields, and to show the clinical consequences of a multiple beam irradiation in a stereotactic head phantom. A maximum photon energy of 1.2 +/- 0.1 MeV was determined for the intermediate energy x-ray spectrum at the expense of a low dose rate. A digital microscope with a computer controlled translation stage was investigated for its ability to resolve steep dose gradients in Gafchromic EBT film for field sizes as small as 1 mm and for photon energies as low as 100 kVp. The microscope-film system resolved gradients to within about 30 mum, limited by the inherent spatial resolution of the film, the noise of the system, and the uncertainties of measurement. Penumbra widths were compared for 1.2 MV versus 6 MV for identical irradiation conditions. In some instances, there was a five-fold reduction in the radiological penumbra of single 1.2 MV x-ray beams. A multiple beam arc irradiation demonstrated that the advantages seen with single beams carry over to multiple beams. The benefits of reduced radiological penumbra for

  14. Assessment of management alternatives for LWR wastes. Volume 7. Cost and radiological impact associated with near-surface disposal of reactor waste (French concept)

    International Nuclear Information System (INIS)

    Malherbe, J.

    1993-01-01

    This report deals with the determination of the cost and the radiological impact associated with a near-surface disposal site (French concept) for low and medium-level radioactive waste generated during operation of a 20 GWe nuclear park composed of LWRs for 30 years. This study is part of an overall theoretical exercise aimed at evaluating a selection of management routes for LWR waste based on economical and radiological criteria

  15. Assessment of radiological safety of some new diagnostic agents used in nuclear medicine investigations

    International Nuclear Information System (INIS)

    Gupta, M.M.; Nagaratnam, A.

    1993-01-01

    Effective dose estimations have been carried out for some newer technetium-99m labelled diagnostic agents employed for myocardial and regional cerebral perfusion studies. Mean absorbed doses due to these preparations were taken from published literature. Effective dose was calculated by multiplying mean absorbed dose to an organ or tissue by the value of tissue weighting factor assigned to that organ or tissue in the recommendations of the international Commission on Radiological Protection and integrating over all organs or tissues of interest. The process was repeated considering revised values of tissue weighting factors as recommended recently. A method for approximate effective dose calculation is described in cases where complete data on mean absorbed dose or tissue weighting factor for an organ or tissue are not available. Revised values of tissue weighting factor normally result in a lowering of estimated effective doses due to these radiopharmaceuticals. It was also demonstrated that additional total stochastic risk will only be marginal. (author)

  16. A model to determine the radiological implications of non-fixed radioactive contamination on the surfaces of packages and conveyances

    International Nuclear Information System (INIS)

    Hughes, J.S.; Warner Jones, S.M.; Lizot, M.T.; Perrin, M.L.; Thierfeld, S.; Schroedl, E.; Schwarz, G.; Rawl, R.; Munakata, M.; Hirose, M.

    2004-01-01

    The surfaces of packages and conveyances used to transport radioactive materials can sometimes become contaminated with radioactive material. This usually occurs as a result of the transfer of radioactive material from areas in which these packages and conveyances are handled. This contamination may subsequently be transferred to transport equipment, workers and to areas accessible to the public. This can represent a significant radiation safety issue that requires careful management. The current regulatory limits for non-fixed contamination on packages and conveyances have been in use for over 40 years, and are based on a simple exposure model. However, the bases on which these limits were derived have been subject to changes, as a result of successive revisions of international recommendations. In recognition of this need for a review and analysis of the current contamination limits an IAEA Co-ordinated Research Project (CRP) on the ''Radiological Aspects of Package and Conveyance Non-Fixed Contamination'' was initiated to review the scientific basis for the current regulatory limits for surface contamination. The CRP was also to develop guidance material for evaluating the radiological significance of surface contamination to workers and the public in light of state-of-the-art research, technical developments and current transport practices. The specific objectives of the work undertaken within this multi-national CRP were, in accordance with the terms of reference: To ensure that appropriate models exist for all package types including consideration of the aspects pertinent for assessing and revising a surface contamination model for transport. To collect - where possible - contamination, operational and dosimetric data to ensure modelling consistency. To use models for assessing the limitations and optimisation of radiation doses incurred in transport operations, and to consider preventive methods for package and conveyance contamination

  17. Results of the radiological and chemical characterization of surface impoundments 3539 and 3540 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Murray, M.E.; Rose, D.A.; Brown, K.S.; Winton, W.; Dean, R.A.; Coe, R.H. III

    1998-03-01

    A radiological and chemical characterization survey of impoundments 3539 and 3540 at the Oak Ridge National Laboratory (ORNL) was conducted during December 1997. Impoundments 3539 and 3540 are located in the Surface Impoundments Operable Unit (SIOU) of Waste Area Group 1. The investigation was performed by the Measurement Applications and Development Group of the Life Sciences Division of ORNL at the request of the Department of Energy (DOE) Office of Environmental Restoration. Sampling was conducted in order to quantify the presence of polychlorinated biphenyls (PCBs), Resource Conservation and Recovery Act (RCRA) constituents, and other contaminants of interest in support of the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) remediation for the SIOU> The survey included collection of sediment/clay samples, quality control blank water samples and equipment rinsate samples for chemical and radiological analysis. Results show the samples contain traces of various organic, inorganic, and radioactive materials. Of particular interest are PCB values which demonstrate the impoundments are not regulated under the Toxic Substances Control Act.

  18. Results of the radiological and chemical characterization of surface impoundments 3539 and 3540 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Murray, M.E.; Rose, D.A.; Brown, K.S.; Winton, W.; Dean, R.A.; Coe, R.H. III

    1998-03-01

    A radiological and chemical characterization survey of impoundments 3539 and 3540 at the Oak Ridge National Laboratory (ORNL) was conducted during December 1997. Impoundments 3539 and 3540 are located in the Surface Impoundments Operable Unit (SIOU) of Waste Area Group 1. The investigation was performed by the Measurement Applications and Development Group of the Life Sciences Division of ORNL at the request of the Department of Energy (DOE) Office of Environmental Restoration. Sampling was conducted in order to quantify the presence of polychlorinated biphenyls (PCBs), Resource Conservation and Recovery Act (RCRA) constituents, and other contaminants of interest in support of the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) remediation for the SIOU> The survey included collection of sediment/clay samples, quality control blank water samples and equipment rinsate samples for chemical and radiological analysis. Results show the samples contain traces of various organic, inorganic, and radioactive materials. Of particular interest are PCB values which demonstrate the impoundments are not regulated under the Toxic Substances Control Act

  19. Pathological and radiological investigations on osteochondrosis in pigs, associated with leg weakness

    International Nuclear Information System (INIS)

    Jørgensen, B.; Arnbjerg, J.; Aaslyng, M.

    1995-01-01

    Two-hundred and seventy-eight Danish Landrace boars were examined radiologically and pathologically for osteochondrosis and other joint lesions on the left legs at slaughter (95 kg). The joint changes were scored on a scale from 1 (normal) to 5 (very severe changes/osteochondritis dissecans). The correlations between radiological and pathological scores were highly significant in the humeral condyles (r = 0.66, P lt 0.001), the distal ulna growth plate (r = 0.51, P lt 0.001), the femoral condyles (r = 0.33, P lt 0.001) and hock (distal tibia (r = 0.17, P lt 0.01) and the medial trochlear ridge of the talus (r = 0.17, P lt 0.01), indicating that radiographical examination is a useful method for diagnosing osteochondrosis in live pigs. Thickening of cartilage was strongly associated with subchondral lesions in the three predilection sites: the humeral condyle, the femoral condyles and the distal ulna growth plate. Osteochondritis dissecans (OCD) in the humeral condyles was significantly associated with subchondral lesions (OR= 1.86; P lt 0.001), but not with cartilage thickness when analysed simultaneously. There were no associations between lesions in the distal ulna growth place, the humeral condyles, the femoral condyles or the anconeal process. There was no significant correlation' between OCD in the humeral condyles and the anconeal process. Osteochondrosis could therefore not be stated to be a generalized disorder. Regression coefficients between joint changes and leg weakness symptoms judged before slaughter were very small and showed no clear trends. OCD in the humeral condyles was, however, significantly associated with 'legs turned out on fore (OR = 2.48; P lt 0.001) and hind (OR = 1.62; P lt 0.05) legs', and OCD in the anconeal process with 'stiff movement in front' (OH+OR = 2.01; P lt 0.05). Osteochondrosis is thus comparable with a threshold trait, where the threshold is the development of an OCD in an osteochondrosis injured joint

  20. Radiological investigation in the outside area of expedition's room during radiopharmaceuticals' expedition

    International Nuclear Information System (INIS)

    Reina, Luiz C.; Monteiro, Ilka H.T.S.; Silva, Joao Carlos P. da; Teixeira, Danilo L.; Pedro, C.R.; Santos, J. Regis dos

    2013-01-01

    Radiopharmaceuticals produced in IEN - Instituto de Engenharia Nuclear of the Brazilian Nuclear Energy Commission, are issued by the radiation protection team, which is responsible for preparing and issuing the packaged documentation required for movement in modal transportation. The documents are: Invoice , Shipper's Declaration of Radioactive Material , Shipper's Declaration of Dangerous Goods - (form IATA ) , Emergency Sheet, sketch of packed. All this documentation is inserted in an envelope of emergency. The Department of Radiological Protection is responsible for issuing such documents except the invoice that is issued by the Commercial Sector (Setcom). A employee of this sector is responsible for delivering it to the shipment sector. The preparation of packaged and documentation is performed in a room located in the building of Radiopharmaceutical Division. The vehicles which are used in the transport are parked outside this building, where are monitored after commissioning of packaged. The present study aims to evaluate potential and occupational radiation risks of people in transit or remain in the area where radioactive material circulates due to the shipment of radiopharmaceuticals for the classification of the area during the operation of dispatch

  1. Unexplained developmental delay/learning disability: guidelines for best practice protocol for first line assessment and genetic/metabolic/radiological investigations.

    Science.gov (United States)

    O'Byrne, J J; Lynch, S A; Treacy, E P; King, M D; Betts, D R; Mayne, P D; Sharif, F

    2016-02-01

    Investigation of patients, particularly children, with unexplained global developmental delay (GDD)/learning disability (LD) has been challenging due to a lack of clear guidance from specialised centres. Limited knowledge of rare diseases and a poor understanding of the purpose or limitations of appropriate investigations have been some of the principal reasons for this difficulty. A guideline development group was formed to recommend on appropriate, first line metabolic, genetic and radiological investigations for children and adults with unexplained GDD/ID. A comprehensive literature search was conducted, evaluated and reviewed by the guideline committee and a best practice protocol for first line assessment and genetic, metabolic and radiological investigations was decided upon after considering diagnostic yield, practicality, treatability and costs. It is hoped that these recommendations will become national guidelines for the first line metabolic, genetic and radiological investigation of patients presenting with unexplained GDD/ID.

  2. Investigation of dosimetric characteristics of the high sensitivity LiF:Mg,Cu,P Thermoluminescent Dosemeter and its applications in diagnostic radiology - a review

    Energy Technology Data Exchange (ETDEWEB)

    Fung, K.L. E-mail: orkarl@polyu.edu.hk

    2004-05-01

    This study investigated the dosimetric properties of the high sensitivity TLD (Thermoluminescent Dosemeter) of LiF:Mg,Cu,P and its applications in diagnostic radiology. A reproducible readout and annealing regime for this high sensitivity TLD was developed in the initial part of this study with the newly installed automatic TLD Reader system. Basic dosimetric characteristics of this T.L. dosemeter were then investigated. This paved the foundation for subsequent selected novel application studies in diagnostic radiology. This study exploits the favourable dosimetric properties of these T.L. dosemeters in some selected novel dosimetric applications in diagnostic radiology with an anthropomorphic phantom. The applications studied in radiological procedures included: dose reduction in lumbar spine radiography utilizing the 'anode heel effect'; gonad dose variation with kV{sub p} in chest radiography; foetal dose comparison between computed tomography (CT) and computed radiography (CR) in X-ray pelvimetry; lens dose reduction with bismuth eye-shields in CT brain studies; foetal dose assessment of early pregnancy in common high risk radiological examinations. It is anticipated that the unique and favourable dosimetric performance of LiF:Mg,Cu,P T.L. phosphor will be exploited further in measurements of low level dose received by patients and staff in diagnostic radiological procedures such as paediatric X-ray examinations.

  3. Investigation of surface deformations by double exposure holographic interferometry

    International Nuclear Information System (INIS)

    Ecevit, F.N.; Guven, H.; Aydin, R.

    1990-01-01

    Surface deformations of rigid bodies produced by thermal as well as mechanical strains have been investigated using double-exposure holographic interferometry. The recorded interference fringes have been discussed qualitatively. (author). 9 refs, 4 figs

  4. Usefulness of laboratory and radiological investigations in the management of supraventricular tachycardia.

    Science.gov (United States)

    Ashok, Aadith; Cabalag, Miguel; Taylor, David McD

    2017-08-01

    Although ED patients presenting with supraventricular tachycardia (SVT) are commonly investigated, the value of these investigations has been questioned. We aimed to determine the frequency and utility of investigations in patients with SVT. We undertook an explicit retrospective medical record audit of patients with SVT who presented to a single ED (January 2004 to June 2014). Data on demographics, presenting complaints, investigations and outcomes were extracted. The outcomes were nature and utility of investigations. A total of 633 patients were enrolled (mean [SD] age 55.4 [17.7] years, 62% female). Laboratory investigations were common: electrolytes (83.7% of patients), full blood count (81.2%), magnesium (57.5%), calcium (39.3%) and thyroid function (30.3%). These investigations revealed many mildly abnormal results but resulted in electrolyte supplementation in only 19 patients: eight with mild hypokalaemia (potassium 3.0-3.5 mmol/L) and 11 with mild hypomagnesia (magnesium 0.49-1.1 mmol/L). Troponin was ordered for 302 (47.7%) patients, many of whom had no history or risk factors for cardiac disease, or ischaemic symptoms associated with their SVT. The troponin was normal, mildly and moderately elevated in 65.2, 24.5 and 10.2% of cases, respectively. Only seven (1.1%) patients were diagnosed with acute myocardial ischemia. Although 190 (30.0%) patients had a chest X-ray (CXR), it was normal in 78.4% of cases. All CXR abnormalities were incidental and not relevant to the immediate ED management. Patients with uncomplicated SVT are over-investigated. Guidelines for ED SVT investigation are recommended. Further research is recommended to determine the indications for each investigation in the setting of SVT. © 2017 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  5. Radiological investigations in the western Baltic Sea including Kattegat during the years 1975 to 1980

    International Nuclear Information System (INIS)

    Kautsky, H.

    1981-01-01

    During the years 1975 to 1980 measurements of the actitivity concentrations of 137 Cs and 90 Sr in the water of the Kattegat and the western Baltic were carried out by the Deutsches Hydrographisches Institut. From these observations it can be clearly seen that the main activity concentration of 137 Cs occurs in the deeper water layers in particular those of the eastern Kattegat and north of the Sound. This water of higher salinity originates from the North Sea and flows through the Kattegat into the Baltic. Higher activity concentration values up to 1.1 pCi/l were found in 1980 only in the region north of the Kiel Bight. These values can be explained by an inflow of water through the Great Belt, where values of up to 2.2 pCi/l were found in the deep water. In March 1980 a value of 3.10 pCi/l was found in the deep water of the Sound. Nevertheless, the activity concentrations in the deep water layers in the Baltic region south of the Sound are not higher than those of the surface water. In this region surface water und deep water have comparable salinity values. In 1980 up to 0.86 pCi 137 Cs were measured in the deep water east of Bornholm, compared with 0.45 pCi/l in the surface water at the same place. In the region west of Bornholm, between Bornholm and the Sound, the activity concentrations are on the same level in both surface water and deep water, namely in the range between 0.44 pCi/l and 0.50 pCi/l. (orig.) [de

  6. Analysis of bacterial contamination on surface of general radiography equipment and CT equipment in emergency room of radiology

    International Nuclear Information System (INIS)

    Hong, Dong Hee; KIm, Hyeong Gyun

    2016-01-01

    We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test

  7. Analysis of bacterial contamination on surface of general radiography equipment and CT equipment in emergency room of radiology

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Dong Hee; KIm, Hyeong Gyun [Dept. of Radiological Science, Far East University, Eumseong (Korea, Republic of)

    2016-09-15

    We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.

  8. Influence of surface treatment on osseointegration of dental implants: histological, histomorphometric and radiological analysis in vivo.

    Science.gov (United States)

    Calvo-Guirado, José Luis; Satorres-Nieto, Marta; Aguilar-Salvatierra, Antonio; Delgado-Ruiz, Rafael Arcesio; Maté-Sánchez de Val, José Eduardo; Gargallo-Albiol, Jordi; Gómez-Moreno, Gerardo; Romanos, Georgios E

    2015-03-01

    The aim of this article is to compare the influence of surface treatment on the integration (at 2, 4 and 8 weeks) of 120 dental implants inserted in 60 tibiae of rabbits. Four different surfaces were double-blind tested: blasted, acid-etched and discrete crystal deposition (DCD) (group A); blasted (group B); acid-etched (group C) and blasted and acid-etched (group D). Bone-to-implant contact plus reverse torque and bone level were measured at the time of implant insertion and at 14, 28 and 56 days of healing. Group A showed the highest early and late bone-to-implant contact (BIC) values: 40.8 ± 2.3 % at 14 days decreasing to 27.7 ± 1.1 % after 28 days and 39.4 ± 1.4 % at 56 days. For group B, the average BIC values at 14, 28 and 56 days were 23.34 ± 2.1, 23.77 ± 1.9 and 29.47 ± 1.7 %, respectively. Group C showed a value of 25.72 ± 2.3 % after 14 days of integration, 34.92 ± 2.2 % at 28 days and 32.91 ± 1.6 % at 56 days. Group D showed a BIC value of 32 ± 2.5 % at 14 days, 32.85 ± 1.4 % at 28 days and 34.04 ± 2.3 % at 56 days. In the scanning electron microscopy (SEM) analysis, no statistically significant differences were found. The Ca/P ratio values were 1.762 for surface A, 1.625 for surface B, 1.663 for surface C and finally 1.722 for surface D. Therefore, we conclude that even if there seems to be a tendency to obtain better BIC results with surface A (blasted-etched and covered with hydroxyapatite (HA)), no statistical differences were obtained in this study. The study shows the influence of different implant surfaces in increasing osseointegation for immediate loading implants.

  9. A radiological and chemical investigation of the 7500 Area Contamination Site at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Williams, J.K.; Foley, R.D.; Tiner, P.F.; Hatmaker, T.L.; Uziel, M.S.; Swaja, R.E.

    1993-05-01

    A radiological and chemical investigation of the 7500 Area Contamination Site at Oak Ridge National Laboratory (ORNL) was conducted intermittently from February 1992 through May 1992. The investigation was performed by the Measurement Applications and Development Group of the Health and Safety Research Division of ORNL at the request of the US Department of Energy's Oak Ridge Operations Office and the ORNL Environmental Restoration Program. Results of this investigation indicate that the source of radioactive contamination at the point of the contamination incident is from one of the underground abandoned lines. The contamination in soil is likely the result of residual contamination from years of waste transport and maintenance operations (e.g., replacement of degraded joints, upgrading or replacement of entire pipelines, and associated landscaping activities). However, because (1) there is currently an active LLW line positioned in the same subsurface trench with the abandoned lines and (2) the physical condition of the abandoned lines may be brittle, this inquiry could not determine which abandoned line was responsible for the subsurface contamination. Soil sampling at the location of the contamination incident and along the pipeline route was performed in a manner so as not to damage the active LLW line and abandoned lines. Recommendations for corrective actions are included

  10. A radiological and chemical investigation of the 7500 Area Contamination Site at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Williams, J.K.; Foley, R.D.; Tiner, P.F.; Hatmaker, T.L.; Uziel, M.S.; Swaja, R.E.

    1993-05-01

    A radiological and chemical investigation of the 7500 Area Contamination Site at Oak Ridge National Laboratory (ORNL) was conducted intermittently from February 1992 through May 1992. The investigation was performed by the Measurement Applications and Development Group of the Health and Safety Research Division of ORNL at the request of the US Department of Energy`s Oak Ridge Operations Office and the ORNL Environmental Restoration Program. Results of this investigation indicate that the source of radioactive contamination at the point of the contamination incident is from one of the underground abandoned lines. The contamination in soil is likely the result of residual contamination from years of waste transport and maintenance operations (e.g., replacement of degraded joints, upgrading or replacement of entire pipelines, and associated landscaping activities). However, because (1) there is currently an active LLW line positioned in the same subsurface trench with the abandoned lines and (2) the physical condition of the abandoned lines may be brittle, this inquiry could not determine which abandoned line was responsible for the subsurface contamination. Soil sampling at the location of the contamination incident and along the pipeline route was performed in a manner so as not to damage the active LLW line and abandoned lines. Recommendations for corrective actions are included.

  11. Tribological and stability investigations of alkylphosphonic acids on alumina surface

    International Nuclear Information System (INIS)

    Cichomski, M.; Kośla, K.; Grobelny, J.; Kozłowski, W.; Szmaja, W.

    2013-01-01

    Alumina substrates are commonly used for various micro-/nanoelectromechanical systems (MEMS/NEMS). For efficient and lifetime longevity of these devices, lubricant films of self-assembled monolayers (SAMs) with nanometer thickness are increasingly being employed. In the present paper, we report preparation, tribological and stability investigations of alkylphosphonic acids on the alumina surface. The alkylphosphonic acids were prepared on the alumina surface using the liquid phase deposition method. The effectiveness of modification of the alumina surface by alkylphosphonic acids was investigated using water contact angle measurements, secondary ion mass spectrometry, X-ray photoelectron and infrared spectroscopy. Frictional behavior in milinewton load range was studied by microtribometry. It is shown that surface modification of the alumina surface by alkylphosphonic acids reduces the coefficient of friction values compared to the unmodified alumina. In comparison to the non-modified alumina surface, all tested alkylphosphonic acids cause a decrease in the friction coefficients in friction tests for counterparts made from different materials, such as steel, zirconia and silicon nitride. It is also found that the alumina surface modified by alkylphosphonic acids with longer chain has a higher degree of hydrophobicity and lower coefficient of friction. The best frictional properties are obtained for the system consisting of the alumina surface modified by n-octadecylphosphonic acid and silicon nitride counterpart. Stability tests in different environmental conditions: laboratory, acidic and alkaline solutions were also monitored.

  12. The Martian Dust Cycle: Investigation of the Surface Lifting Component

    Science.gov (United States)

    Murphy, James R.; Bridger, Alison F. C.; Haberle, Robert M.

    1996-01-01

    We have investigated the nature of the annual cycle of suspended dust in the martian atmosphere. This has been undertaken to understand the dynamical processes responsible for lifting dust from the surface, locations where dust is preferentially lifted, and preferred sites for dust deposition upon the surface. Our efforts have involved carrying out a number of numerical simulations with the Ames Mars General Circulation Model (GCM) interactively coupled with an aerosol transport/ micro-physical model. The model generates an annual dust cycle similar to that observed. Various feedbacks are present in the atmosphere/ surface system which enter into the generation of the cycle. Several locations are primary surface sources of dust, while much of the remaining planet's surface acts a sink for suspended dust.

  13. Investigation of the radiological impact of reactor accidents under probabilistic aspects

    International Nuclear Information System (INIS)

    Huebschmann, W.; Vogt, S.

    1977-01-01

    An analysis and conceptional investigation have been performed for the accident consequence model of the German reactor risk study. A dynamic atmospheric diffusion model is developed, which is applied in the first stage of the study to all distance ranges, and will be restricted finally to the long distance range. The wind direction and its variations are not taken into account in this model. The program set UFO-BAS calculates the time integrated nuclide concentration in air at any location downwind of the source. A further model which takes into account wind direction variations is being developed. On the basis of the proposals for the calculation of the health effects in the German risk study considerations on the storage requirements were accomplished. By means of these assessments a revised grid of parameters was evaluated. Furthermore, considerations were made for the implementation of an evaluation model, which will be developed by the Institut fuer Unfallforschung. (orig./RW) [de

  14. Methodological foundations of control of competitive power of investigations in medical radiology

    International Nuclear Information System (INIS)

    Gorbushin, N.G.

    1987-01-01

    One of the problems of raising the efficacy and acceleration of investigations and developments under the conditions of scientific technical progress is competitive power of products and technologies. The problem is especially acute in international economic cooperation when one must choose an object of license and lines of research promoting its development. The existing mechanisms of control do not ensure reliable solution of this problem and need to be improved. The paper is concerned with the consideration of routine approaches to control of competitive power; new mechanisms based on algorithmic methods using a clustering analysis of patent and scientific medical information have been proposed. The author shows a possibility of building up the functional structure of research pursued in one or several institutions involved in the development of a multipurpose problem, and the choice of directions of research, among them potential objects for license sale and concluding an agreement of international cooperation on a contract basis

  15. Investigating the Relationship of Sociodemographic and Personality Factors to Faculty Perceptions and Motivations Regarding the Use of Online Instruction in Radiologic and Imaging Sciences

    Science.gov (United States)

    Washington, Angela E.

    2012-01-01

    The purpose of this quantitative correlational study was to investigate the relationship of sociodemographic and personality traits to faculty perceptions and motivations regarding the use of online instruction in radiologic and imaging sciences. A faculty perception and motivations survey of online instruction was administered online in order to…

  16. Epidemiological investigation of radiological effects in high background radiation areas of Yangjiang, China

    International Nuclear Information System (INIS)

    Wei, Luxin; Zha, Yongru; Tao, Zufan; He, Weihui; Chen, Deqing; Yuan, Yongling

    1990-01-01

    The purpose of this investigation is to provide some information for providing whether any detrimental effects exist in a large population whose families have been continuously exposed to a low dose rate radiation. Two areas in Yangjiang Country, characterized by high background radiation (HBR) with environmental gamma exposure, large population size and long-term inhabitants, were selected for evaluation of late effects of HBR. The areas with normal radiation background close to the Yangjiang Country were selected as control areas. Up to 1986 approximately one million person-years in each area in both HBR and control areas have been observed. No increase of cancer mortality was found in the HBR areas; on the contrary, cancer mortality tended to be lower in the HBR areas than the control areas. The prevalence of hereditary diseases and congenital defects was similar in both HBR and control areas, but the frequency of Down's syndrome was higher in the HBR areas (through within the normal range) than the control areas. A possible explanation is the difference of age of maternity between the HBR and control areas, and the extremely low frequency in the control areas. Possible factors influencing the incidence of mutationbased diseases were comparable in the HBR and control groups. However, the cultural and educational levels were somewhat different, probably affecting health status and family planning. It is likely that there may be a dose threshold for cancer incidence, but this remains to be determined by further research. (N.K.)

  17. Investigation of surface halide modification of nitrile butadiene rubber

    Science.gov (United States)

    Sukhareva, K. V.; Mikhailov, I. A.; Andriasyan, Yu O.; Mastalygina, E. E.; Popov, A. A.

    2017-12-01

    The investigation is devoted to the novel technology of surface halide modification of rubber samples based on nitrile butadiene rubber (NBR). 1,1,2-trifluoro-1,2,2-trichlorethane was used as halide modifier. The developed technology is characterized by production stages reduction to one by means of treating the rubber compound with a halide modifier. The surface halide modification of compounds based on nitrile butadiene rubber (NBR) was determined to result in increase of resistance to thermal oxidation and aggressive media. The conducted research revealed the influence of modification time on chemical resistance and physical-mechanical properties of rubbers under investigation.

  18. Emergency pediatric radiology

    Energy Technology Data Exchange (ETDEWEB)

    Carty, H. [ed.

    1999-11-01

    This unique book covers the main clinical presentations of children to an emergency room and considers in detail the radiological investigation of such emergencies. Numerous high-quality illustrations of the radiological manifestations of acutely presenting illness in children ensure that the volume will serve as a rapid reference source for both pediatricians and radiologists. All of the authors are specialist pediatric radiologists who provide emergency radiological services on a daily basis, and the text reflects this level of expertise. (orig.)

  19. Investigation of zones with increased ground surface gamma radiation

    International Nuclear Information System (INIS)

    Butkus, D.V.; Morkunas, G.S.; Styro, B.I.

    1989-01-01

    Measurements of the increased gamma radiation zones of soils were conducted in the South-Western part of the Litvinian. The shores of lakes in the north-eastern part of the Suduva high land were investigated. the maximum values of the gamma radiation dose rates were distributed along the lake shores at a distance of 1 m from the water surface, while farther than 1.5 m from it the dose rate was close to the natural value. The increased gamma radiation intensity zones on the ground surface were found only at the northern (Lake Reketija) or the western shore (other lakes under investigation). The highest values of the gamma radiation dose 200-600 μR/h (0.5-1.5 nGy/s) were observed in the comparatively small areas (up to several square metres). The gamma radiation intensity of soil surface increased strongly moving towards the point where the maximum intensity was obsered. 10 figs

  20. Investigation of the surface adsorption and biotribological properties of mucins

    DEFF Research Database (Denmark)

    Madsen, Jan Busk

    to a surface. However, in other instances the inverse properties are desirable. Mucins are found on epithelial surfaces throughout the body and are a key component of the mucus barrier. Here, they facilitate friction reduction, thus lowering the impact of physical abrasions, but they also act as a physical...... and their aqueous lubrication properties have led to them being proposed as possible biocompatible lubricants. In this thesis, we investigate the biotribological properties of two commercially available mucins on the soft, elastomeric and hydrophobic surface of PDMS under different conditions. Due to the presence...... of a significant amount of non-mucin biomolecules in the commercial mucins, a mild single column protein purification protocol was established. In the mucin biotribology community, many employ the mucins either “as received” or after dialysis. It was therefore investigated how the established purification process...

  1. Radiological clerkships as a critical curriculum component in radiology education

    International Nuclear Information System (INIS)

    Kourdioukova, Elena V.; Verstraete, Koenraad L.; Valcke, Martin

    2011-01-01

    Objective: The aim of this research was to explore the perceived value of clinical clerkships in the radiology curriculum as well as the impact of radiology clerkship on students' beliefs about the profession of radiology as a whole and as a career. Methods: This study is a sequel to a previous survey in which student perceptions about radiology curriculum components were investigated. The present study focuses on a further analysis of a subsection in this study, based on 14 statements about radiology clerkship and two statements about radiology as a career. Results: Perceived usefulness of the aspects of radiology clerkship as 'radiology examination', 'skills development' and 'diagnosis focus' were awarded the highest scores. The predict value of the subscale 'radiology examination' on the level of performance was very high (adjusted R 2 = 0.19, p < .001). Conclusion: Students expressed highly favorable evaluation of clerkship as a learning environment to learn to order and to interpret imaging studies as well as an unique possibility to attend various radiological examinations and to access to specific radiology software systems, as well as to get a better view on radiology and to improve image interpretation skills. This positive attitude towards clerkship is closely tied to students' beliefs about the profession of radiology as a whole. These aspects of dedicated radiology clerkship are crucial for effective and high-quality education as well as for the choice of radiology as a career.

  2. Investigating the resetting of OSL signals in rock surfaces

    DEFF Research Database (Denmark)

    Sohbati, Reza; Murray, Andrew S.; Jain, Mayank

    2011-01-01

    signals in grains and slices from five different cobbles/boulders collected from a modern beach is investigated. All the rock surfaces are presumed to have been exposed to daylight for a prolonged period of time (weeks to years). Feldspar was identified as the preferred dosimeter because quartz extracts...... factors were derived for two samples. These indicate that, for instance, bleaching at a depth of 2 mm into these samples occurs at about ∼28% of the rate at the surface. We conclude that it should be possible to derive meaningful burial doses of >1 Gy from such cobbles; younger samples would probably...

  3. Frequency distribution of specific activities and radiological hazard assessment in surface beach sand samples collected in Bangsaen beach in Chonburi province, Thailand

    Science.gov (United States)

    Changkit, N.; Boonkrongcheep, R.; Youngchauy, U.; Polthum, S.; Kessaratikoon, P.

    2017-09-01

    The specific activities of natural radionuclides (40K, 226Ra and 232Th) in 50 surface beach sand samples collected from Bangsaen beach in Chonburi province in the easthern region of Thailand, were measured and evaluated. Experimental results were obtained by using a high-purity germanium (HPGe) detector and gamma spectrometry analysis system in the special laboratory at Thailand Institute of Nuclear Technology (Public Organization). The IAEA-SOIL-375 reference material was used to analyze the concentration of 40K, 226Ra and 232Th in all samples. It was found that the specific activities of 40K, 226Ra and 232Th were ranged from 510.85 - 771.35, 8.17 - 17.06 and 4.25 - 15.68 Bq/kg. Furthermore, frequency distribution of the specific activities were studied, analyzed and found to be the asymmetrical distribution by using a statistical computer program. Moreover, four radiological hazard indices for the investigated area were also calculated by using the median values of specific activities of 40K, 226Ra and 232Th. The results were also compared with the Office of Atoms for Peace (OAP) annual report data, Thailand and global radioactivity measurement and evaluations.

  4. Surface investigation of chitosan film with fatty acid monolayers

    Directory of Open Access Journals (Sweden)

    Esam A. El-hefian

    2009-05-01

    Full Text Available The surface pressure- molecular area (-A isotherm curves of two fatty acids of different chain lengths, i.e. stearic (C18 and arachidic (C20 acids, were obtained by using Langmuir-Blodgett (LB technique. Results showed clear isotherm plots with limiting mean molecular area around 21 Å2 for both acids. However, the monolayer was found to collapse at higher than 33 mN m-1 and 21 mN m-1 for stearic acid and arachidic acid respectively. The effect of Langmuir-Blodgett monolayers of the acids was investigated by atomic force microscopy (AFM. Chitosan film, before and after dipping in water, was also studied by means of AFM so that it could be used for comparison. It was found that the surface of chitosan was more homogeneous and smoother after dipping in water. In addition, more homogeneous surfaces were achieved after transferring a layer of the fatty acid onto the substrate.

  5. Investigation of surface effect on giant magnetoimpedance in microwires

    International Nuclear Information System (INIS)

    Tousignant, M.; Zabeida, O.; Rudkowska, G.; Yelon, A.

    2014-01-01

    Previous work from our group suggested that the giant magnetoimpedance (GMI) response of soft ferromagnetic microwires could be improved by removing a hypothetical hard magnetic shell on the surface of the cylindrical conductors. Therefore, we have been trying to increase the sensitivity of our samples by exposing them to a mild plasma etching treatment. Although we measured a reduction in diameter of the microwires and ensured that their bulk magnetic properties remained unchanged, it was found that the surface treatment did not improve the GMI behavior of the samples. We thus conclude that the sensitivity of ferromagnetic microwires must be limited by bulk inhomogeneities, yet to be investigated. - Highlights: • We have been trying to increase the sensitivity of our samples by exposing them to a mild plasma etching treatment. • Surface treatment did not improve the GMI behavior of the samples

  6. Effects of XPS operational parameters on investigated sample surfaces

    International Nuclear Information System (INIS)

    Mrad, O.; Ismail, I.

    2013-04-01

    In this work, we studied the effects of the operating conditions of the xray photoelectron spectroscopy analysis technique (XPS) on the investigated samples. Firstly, the performances of the whole system have been verified as well as the accuracy of the analysis. Afterwards, the problem of the analysis of insulating samples caused by the charge buildup on the surface has been studied. The use of low-energy electron beam (<100 eV) to compensate the surface charge has been applied. The effect of X-ray on the samples have been assessed and was found to be nondestructive within the analysis time. The effect of low- and high-energy electron beams on the sample surface have been investigated. Highenergy electrons were found to have destructive effect on organic samples. The sample heating procedure has been tested and its effect on the chemical stat of the surface was followed. Finally, the ion source was used to determine the elements distribution and the chemical stat of different depths of the sample. A method has been proposed to determine these depths (author).

  7. Raman and surface enhanced Raman spectroscopic investigation on Lamiaceae plants

    Science.gov (United States)

    Rösch, P.; Popp, J.; Kiefer, W.

    1999-05-01

    The essential oils of Thymus vulgaris and Origanum vulgaris are studied by means of micro-Raman spectroscopy. The containing monoterpenes can be identified by their Raman spectra. Further the essential oils are investigated in their natural environment, the so-called oil cells of these Lamiaceae plants, with surface enhanced Raman spectroscopy (SERS). This method has the advantage to enhance Raman signals and furthermore the SERS effect leads to fluorescence quenching.

  8. Hydraulic investigation on free surface flow of windowless target

    International Nuclear Information System (INIS)

    Hu Chen; Gu Hanyang

    2015-01-01

    The formation and control of free surface are the most essential parts in the studies of windowless target in ACCELERATOR-DRIVEN sub-critical system (ADS). Water model experiments and 360° full scale three dimensional simulations were conducted. The experimental study demonstrates that the free surface is significantly affected by the inlet flow velocity and outlet pressure. The length of free surface decreases in the second order with the increase of inlet flow velocity, while it decreases linearly with the outlet pressure. The structure and feature of flow field were investigated. The results show that the free surface is vulnerable to the vortex movement. Transient simulations were performed with volume of fluid (VOF) method, large eddy simulation (LES) and the pressure implicit with splitting of operators (PISO) algorithm. The simulation results agree qualitatively well with the experimental data related to both free surface flow and flow field. These simulation models and methods are proved to be applicable in the hydraulic simulations of liquid heavy metal target. (authors)

  9. Investigation into the hydrodynamic performance of fouling-release surfaces

    Science.gov (United States)

    Quinn, Ronan Declan

    Silicone fouling release coatings provide the only proven biocide free antifouling method, available to ship and boat operators. These surfaces rely on hydrodynamic forces for the removal of fouling and there is interest in understanding the relationship between biofouling and the hydrodynamic forces required for removal. This research investigated the feasibility of predicting the release of cylinders adhered to silicone with epoxy under hydrodynamic loading using a simple point load adhesion measurement. Adhesion and material science, fracture mechanics and hydrodynamics are complex subjects and a detailed review is presented. Experiments were designed and divided into two main categories. Laboratory measurements, which were undertaken to investigate the factors that affect the adhesion of epoxy to fouling release surfaces, and hydrodynamic experiments that were designed to understand the forces and moments imparted on known shapes. The laboratory experiments determined that the stress at failure of epoxy to a silicone fouling release type surface is determined by coating thickness, rate of loading, how the load is applied, chemistry of the interface, and the mechanical properties of the coating. The hydrodynamic experiments were conducted from a test section built into the hull of a 9 meter power vessel. Glass panels were mounted into an instrument such that the coating surface became an integral part of the boat hull. The instrument included, a pitot static tube, to measure the boundary layer velocity, a six component force balance, to measure the forces and moments imparted on these shapes, and the test glass panel. The panels were coated with a clear silicone and cylinders were adhered using epoxy to the coating. This setup enabled the interface between the silicone and epoxy to be viewed using a high speed digital video camera. From these experiments it was determined that it is possible to relatively predict the failure of a cylinder of any length and

  10. An investigation on mandibular radiometric indices in normal female population referred to maxillofacial radiology centers in Rasht.

    Directory of Open Access Journals (Sweden)

    Dalili Z. Assistant Professor. Moghadam Qujeq A. Dentist.

    2003-08-01

    Full Text Available Statement of Problem: Bone material density (BMD is significantly decreased among postmenopausal women leading to the most common metabolic disease, osteoporosis."nMultiple bone fractures are of the most important consequences of this disease, which cost too much for the"nsociety. One of the cheapest and most available methods for the diagnosis of bone density changes is bone"nradiomorphometric evaluation by conventional methods. Studies have also revealed that mandibular"nradiomorphometric indices in panoramic radiographs yield invaluable information, which can be used as a"nscreening method to diagnose patients with decreasing bone density, and to determine normal values of"nmandibular radiomorphometric indices among normal subjects in different populations."nPurpose: The aim of the present study was to investigate the mandibular radiomorphometric indices in"npanoramic radiographs among normal female population referring to maxillofacial radiology centers to"ndetermine their relationship with age and the total teeth number of the subjects under study."nMaterial and Methods: In this descriptive-analytic study, two mandibular radiomorphometric indices namely"nthe Antegonial quantitative index (AI and the Cortical qualitative index (MCI were evaluated on 417"npanoramic radiographs of a female normal population, aged more than 20 years which divided into five age"ngroup, by one maxillofacial radiologist as an observer. The relationship between these indices, and also with"nthe number of teeth and age were investigated by variance and Pearson's analysis."nResults: Mean quantitative index (AI was 3.54±54%mm. The prevalence of MCI index was C2: 71.5%,"nCI: 20.9%and C3: 7.7%. There was significant correlation between AI/MCI indices with age, dentition and"nalso with each other.(P<0.0001."nConclusion: Based on the present study, with increasing age the mean AI and the number of teeth decrease"nsignificantly. MCI index also shows higher porosity

  11. Radiology fundamentals

    CERN Document Server

    Singh, Harjit

    2011-01-01

    ""Radiology Fundamentals"" is a concise introduction to the dynamic field of radiology for medical students, non-radiology house staff, physician assistants, nurse practitioners, radiology assistants, and other allied health professionals. The goal of the book is to provide readers with general examples and brief discussions of basic radiographic principles and to serve as a curriculum guide, supplementing a radiology education and providing a solid foundation for further learning. Introductory chapters provide readers with the fundamental scientific concepts underlying the medical use of imag

  12. RSVP radiology

    International Nuclear Information System (INIS)

    Kirks, D.R.; Chaffee, D.J.

    1990-01-01

    This paper develops a relative scale of value for pediatric radiology (RSVPR). Neither the HCFA/ACA Relative Value Scale nor the Workload Measurement System developed by Health and Welfare Canada specifically addressed pediatric radiologic examinations. Technical and professional charges for examinations at Children's Hospital Medical Center were reviewed and compared with time and cost analysis. A scale was developed with chest radiography (PA and lateral views) assigned a value of 1. After review by pediatric radiologic technologists, radiologic administrators, pediatric radiologists, and chairs of departments of children's hospitals, this proposed scale was modified to reflect more accurately relative value components of pediatric radiologic and imaging examinations

  13. Hydrogeological investigations at the surface of the Wellenberg region

    International Nuclear Information System (INIS)

    Baumann, A.; Frieg, B.

    1991-01-01

    The aim of the surface investigations carried out at Wellenberg is twofold, namely to provide a record of the actual hydrogeological situation before commencing operations at a site and to suppplement data obtained using other methods. The initial phase involved drawing up an inventory of all springs, streams and groundwater observation points and determining various physical parameters. The observation points are now checked periodically. In order to supplement the network for monitoring groundwater in the valley of the Engelberger Aa, new shallow boreholes have been drilled and equipped as piezometers. Isotopic investigations are carried out on samples of precipitation and spring-water. This allows infiltration conditions, and seasonal variations therein, to be determined. Finally, hydrochemical and bacteriological investigations were carried out for selected springs. (author) 2 figs

  14. Cassini-Huygens Investigations of Satellite Surfaces and Interiors

    Science.gov (United States)

    Lunine, Jonathan I.; Soderblom, Laurence A.

    2002-07-01

    The Saturnian system contains 18 known satellites ranging from 10 km to 2575 km in radius. In bulk properties and surface appearance these objects show less regularity than the sparser Jupiter system. The Galilean-sized moon Titan sports a dense atmosphere of nitrogen and methane which renders surface observations difficult, but also makes this moon intriguing from the standpoints of climate change and exobiology. The Cassini-Huygens mission will make extensive observations of the satellites over a range of wavelengths, as well as using in-situ sampling of satellite environments (and in the case of Titan, sampling of atmosphere and surface). The goals of these extensive investigations are to understand the bulk properties of the satellites, their surface compositions and evolution through time, as well as interactions with the magnetosphere and rings of Saturn. This knowledge in turn should provide a deeper understanding of the origin of the Saturnian system as a whole and underlying causes for the distinctive differences from the Jovian satellite system.

  15. Rational use of diagnostic radiology

    International Nuclear Information System (INIS)

    Racoveanu, N.T.; Volodin, V.

    1992-01-01

    The escalating number of radiodiagnostic investigations has, as a consequence, an increase in medical irradiation of patients and of cost of radiological services. Radiologists in USA and UK have since early 1970 questioned the efficacy of various radiological investigations and produced substantial evidence that more rational approaches are necessary. WHO initiated, in 1977, a programme in this direction which has issued four technical reports which give practical recommendations on how to rationalize the use of radiological examinations. Three main directions are considered: (1) Abandonment of routine radiological examinations, as procedures with no clinical or epidemiologic significance and which represent a waste of resources and patient dose. (2) Patient selection for various radiological investigations based on clinical criteria (high, intermediate, low yield). Selected patients have an increased prevalence of the given disease and the predictive value of radiological investigation is much higher. (3) Use of diagnostic algorithms with higher cost/efficiency and risk/benefit ratios, improving the outcome of radiological examinations

  16. Investigation into the heat transfer performance of helically ribbed surfaces

    International Nuclear Information System (INIS)

    Firth, R.J.

    1981-12-01

    The first part of an investigation into flow and heat transfer in annular channels and seven pin clusters is described. One of the main aims of the project is to improve cluster heat transfer prediction codes for helically ribbed surfaces. A study is made of the heat transfer and flow characteristics of a helically ribbed pin in an annular channel. It is shown that the swirling flow, which is induced by the helical ribs, gives rise to substantially enhanced diffusivity levels. This phenomenon had not been taken into account by previous analysis techniques. The methods for analysing heat transfer and pressure drop data from annular channels which were originally developed for non-swirling flow are generalised to accommodate swirling flow. The new methods are shown to be consistent with empirical data. Roughness parameter data is presented for helically ribbed surfaces with an axial rib pitch into height ratio of about 7. (author)

  17. Radiology illustrated. Pediatric radiology

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In-One (ed.) [Seoul National Univ. College of Medicine (Korea, Republic of). Dept. of Radiology

    2014-11-01

    Depicts characteristic imaging findings of common and uncommon diseases in the pediatric age group. Will serve as an ideal diagnostic reference in daily practice. Offers an excellent teaching aid, with numerous high-quality illustrations. This case-based atlas presents images depicting the findings typically observed when imaging a variety of common and uncommon diseases in the pediatric age group. The cases are organized according to anatomic region, covering disorders of the brain, spinal cord, head and neck, chest, cardiovascular system, gastrointestinal system, genitourinary system, and musculoskeletal system. Cases are presented in a form resembling teaching files, and the images are accompanied by concise informative text. The goal is to provide a diagnostic reference suitable for use in daily routine by both practicing radiologists and radiology residents or fellows. The atlas will also serve as a teaching aide and a study resource, and will offer pediatricians and surgeons guidance on the clinical applications of pediatric imaging.

  18. Radiology illustrated. Pediatric radiology

    International Nuclear Information System (INIS)

    Kim, In-One

    2014-01-01

    Depicts characteristic imaging findings of common and uncommon diseases in the pediatric age group. Will serve as an ideal diagnostic reference in daily practice. Offers an excellent teaching aid, with numerous high-quality illustrations. This case-based atlas presents images depicting the findings typically observed when imaging a variety of common and uncommon diseases in the pediatric age group. The cases are organized according to anatomic region, covering disorders of the brain, spinal cord, head and neck, chest, cardiovascular system, gastrointestinal system, genitourinary system, and musculoskeletal system. Cases are presented in a form resembling teaching files, and the images are accompanied by concise informative text. The goal is to provide a diagnostic reference suitable for use in daily routine by both practicing radiologists and radiology residents or fellows. The atlas will also serve as a teaching aide and a study resource, and will offer pediatricians and surgeons guidance on the clinical applications of pediatric imaging.

  19. Surface analytical investigations at Sandia Labs./Albuquerque

    International Nuclear Information System (INIS)

    Madden, H.H.

    1978-01-01

    An overview is given of some projects which (1) have used surface analytical techniques in a conventional way to investigate specific surface-related problems; (2) have utilized surface studies to get a more fundamental understanding of the operations of various devices and components, and of the factors that determine such parameters as the lifetime and reliability of such devices; and (3) have been undertaken to better understand just what additional information can be extracted from two of the myriad surface analytical techniques, Auger electron spectroscopy (AES) and electron-stimulated desorption (ESD). The examples in the first two categories are directly related weapons work while the examples discussed in the third category provide more general support to weapons programs. Only work in the first category is tabulated. Two examples of work in the second category are the neutron generator project and the design and production of integrated circuits (IC). Tritide-film targets in neutron generator tubes lose their efficiency for neutron production when they have adsorbed surface contaminants such as oxygen. Ion microprobe analysis has been applied to the study of contaminants on and in these films; and thermal desorption spectroscopy has been used to identify, and to determine the binding energy of gases evolved during outgassing of materials used in tube construction. Long-term outgassing determines the lifetime of the vacuum tubes. AES serves as the common thread in the third category projects. Gas phase, core-valence-valence (CVV) Auger lines have been measured in a systematic attempt, utilizing both theory and experimental results, to determine the factors that influence the shapes of the lines. This work demonstrates the local nature of the information on the energy distribution of valence levels contained in the Auger lineshapes

  20. Investigating stellar surface rotation using observations of starspots

    DEFF Research Database (Denmark)

    Korhonen, Heidi Helena

    2011-01-01

    Rapid rotation enhances the dynamo operating in stars, and thus also introduces significantly stronger magnetic activity than is seen in slower rotators. Many young cool stars still have the rapid, primordial rotation rates induced by the interstellar molecular cloud from which they were formed...... information on the rotation of the star. At times even information on the spot rotation at different stellar latitudes can be obtained, similarly to the solar surface differential rotation measurements using magnetic features as tracers. Here, I will review investigations of stellar rotation based...

  1. Microscopic Investigation of Reversible Nanoscale Surface Size Dependent Protein Conjugation

    Directory of Open Access Journals (Sweden)

    Michael A. Carpenter

    2009-05-01

    Full Text Available Aβ1-40 coated 20 nm gold colloidal nanoparticles exhibit a reversible color change as pH is externally altered between pH 4 and 10. This reversible process may contain important information on the initial reversible step reported for the fibrillogenesis of Aβ (a hallmark of Alzheimer’s disease. We examined this reversible color change by microscopic investigations. AFM images on graphite surfaces revealed the morphology of Aβ aggregates with gold colloids. TEM images clearly demonstrate the correspondence between spectroscopic features and conformational changes of the gold colloid.

  2. IR-ATR investigation of surface anisotropy in silicate glasses

    Science.gov (United States)

    Ivanovski, Vladimir; Mayerhöfer, Thomas G.; Kriltz, Antje; Popp, Jürgen

    2017-02-01

    Several samples of flat soda-lime silicate glass were investigated by the Infrared Attenuated Total Reflection (IR-ATR) spectroscopy technique. The specular reflectance spectra together with the results of the performed dispersion analysis and the generated reflectance spectra, using Fresnel equations, suggest that the samples are isotropic. In contrast, spectra recorded by the ATR technique suggest an anisotropic structure on the surface of the specimen different from that in the bulk. This is established through differences in the s- and p-polarized IR-ATR spectra, which cannot be simply transformed into one another employing Fresnel formula for an isotropic case. It appears that this thin film having a structure different from the bulk is larger than the ATR effective penetration depth of the evanescent ray for each incidence angle above the critical one. The investigation suggests C2 symmetry of the SiO4 unit.

  3. Surfaced-based investigations plan, Volume 4: Yucca Mountain Project

    International Nuclear Information System (INIS)

    1988-12-01

    This document represents a detailed summary of design plans for surface-based investigations to be conducted for site characterization of the Yucca Mountain site. These plans are current as of December 1988. The description of surface-based site characterization activities contained in this document is intended to give all interested parties an understanding of the current plans for site characterization of Yucca Mountain. The maps presented in Volume 4 are products of the Geographic Information System (GIS) being used by the Yucca Mountain Project. The ARC/INFO GIS software, developed by Environmental Systems Research Institute, was used to digitize and process these SBIP maps. The maps were prepared using existing US Geological Survey (USGS) maps as a planimetric base. Roads and other surface features were interpreted from a variety of sources and entered into the GIS. Sources include the USGS maps, 1976 USGS orthophotoquads and aerial photography, 1986 and 1987 aerial photography, surveyed coordinates of field sites, and a combination of various maps, figures, descriptions and approximate coordinates of proposed locations for future activities

  4. Chronicle of pediatric radiology

    International Nuclear Information System (INIS)

    Benz-Bohm, Gabriele; Richter, Ernst

    2012-01-01

    The chronicle of pediatric radiology covers the following issues: Development of pediatric radiology in Germany (BRD, DDR, pediatric radiological accommodations); development of pediatric radiology in the Netherlands (chronology and pediatric radiological accommodations); development of pediatric radiology in Austria (chronology and pediatric radiological accommodations); development of pediatric radiology in Switzerland (chronology and pediatric radiological accommodations).

  5. INVESTIGATION OF MICRO AND NANOSTRUCTURE OF HYDROPHOBIC PLANTS SURFACE

    Directory of Open Access Journals (Sweden)

    M. V. Zhukov

    2014-03-01

    Full Text Available Micro and nanostructure of petals and flowers of pink rose family having super hydrophobic phenomenon known as "lotus effect" was studied by optical and scanning probe microscopy. Quasi-ordered corrugated structure was found on the surface of the rose petals. It represents the ensemble of smoothed shape peaks like a lotus leaf structure. Structure saving during dehydration of rose petal (for 5 days by drying in the air under normal conditions was found, the difference is apparent in the density of the arrangement and shape of the peaks, which in case of dehydrated rose petal have a smoother shape. Thus, the typical distance between the structure peaks of the native rose petal was 25-30 mkm, average peak height was 8 mkm, the peak width at half- height was about 15 mkm, peak top approximated by a sphere had a radius of about 2-3 mkm, the slope angle of the surface tangent to the peak axis was about 38-42º. Characteristic distance between the peaks for a dried rose petal is reduced to 20-25 mkm, the average peak height was 8 mkm, the width of the peak at half - height was about 18 mkm, peak top approximated by a sphere had a radius of about 5-6 mkm, the slope angle of the surface tangent to the peak axis was about 40-50º. A thin nanostructure of separate peak was examined on a dried petal, which consists of longitudinal bands of about 150-300 nm in height and about 2-3 mkm in width. While visualizing of rose stem leaves, a cellular structure with micro-pores and nanometer canals on the surface was discovered. The analysis of surface roughness on different parts of investigated objects was held. A single peak roughness was about 650 nm for a living rose petal, 300 nm for dried rose petal, roughness of the rose stem leaf was about 65-70 nm with sizes of scanned areas equal to 10x10 mkm. Studies were conducted on the integrated optical module Optem of Ntegra Aura microscope (NT-MDT, Russia and on the scanning probe microscope NanoEducator LE (NT

  6. Microwave Investigation of the Mars Atmosphere and Surface

    Science.gov (United States)

    Gulkis, S.; Forget, F.; Janssen, M.; Riley, A. L.; Hartogh, P.; Clancy, T.; Allen, M.; Frerking, M.

    2000-01-01

    The Microwave Investigation of the Mars Atmosphere and Surface Experiment (MIMAS) is designed to address two major scientific goals: 1) To understand the three dimensional general circulation of the Martian atmosphere, and 2) To understand the hydrologic cycle of water on Mars, including the time-variable sources, sinks, and atmospheric transport of water vapor. The proposed instrument is a submillimeter wave, heterodyne receiver, with both continuum and very high spectral resolution capability. A small reflector antenna will be used to feed the receiver. Instrument heritage comes from the MIRO receiver, currently under design for the ESA Rosetta Mission, and from SWAS, a NASA astrophysics mission. The instrument will be able to measure atmospheric spectral lines from both water and carbon monoxide and use these lines as tracers of atmospheric winds. Measurement objectives of MIMAS are to measure surface temperature, atmospheric temperature from the surface up to an altitude of 60 km or more, the distribution of CO and H2O in the atmosphere, and certain wind fields (zonal and meridional). The global distribution of CO, as well as temperature distributions, will be used as input data for GCMs (general circulation models). Water vapor profiles will be used to understand the sources and sinks of water on Mars and to understand how it is transported globally by the general circulation. Zonal and meridional wind fields will provide further tests of the GCMs. An important aspect of this experiment is that the temperature and humidity measurements are insensitive to dust and ice condensates thereby making the measurement capability independent of the presence of dust clouds and ice particles. Temperature measurements derived from the data can be used in conjunction with infrared measurements to determine dust profiles.

  7. Investigation of magnetorheological elastomer surface properties by atomic force microscopy

    International Nuclear Information System (INIS)

    Iacobescu, G.E.; Balasoiu, M.; Bica, I.

    2012-01-01

    Magnetorheological elastomers consist of a natural or synthetic rubber matrix interspersed with micron-sized ferromagnetic particles. The magnetoelastic properties of such a composite are not merely a sum of elasticity of the polymer and stiffness and magnetic properties of the filler, but also the result of a complex synergy of several effects, relevant at different length scales and detectable by different techniques. In the present work we investigate the microstructures, the surface magnetic properties and the elastic properties of new isotropic and anisotropic magnetorheological elastomer prepared using silicone rubber and soft magnetic carbonyl iron microspheres. The measurements were performed by atomic force microscopy in the following modes: standard imaging-non-contact atomic force microscopy, magnetic force microscopy and nanoindentation. A comparative study for the samples with different particle concentrations and strength of magnetic field applied during the polymerization process is developed

  8. Experimental investigation of surface roughness in electrical discharge turning process

    Science.gov (United States)

    Gohil, Vikas; Puri, Y. M.

    2016-10-01

    In the present study the effects of machining parameters on the average surface roughness (Ra) in electrical discharge turning (EDT) is investigated. EDT is a new machining process in which a rotary spindle is added to a conventional die-sinking EDM machine in order to produce cylindrical components. In this method a new process parameter (spindle rotation) along with pulse on time and current is introduced to study its effect on Ra. This has been done by means of full factorial design (21 × 32) of experiments. A mathematical model has been developed for Ra by regression analysis and factor effects were analyzed using analysis of variance (ANOVA). Signal-to-noise ratio analysis is used to find the optimal condition.

  9. Dental radiology

    International Nuclear Information System (INIS)

    Bhaskar, S.N.

    1982-01-01

    The book presents the radiological manifestations of the maxillodental region in a suitable manner for fast detection and correct diagnosing of diseases of the teeth, soft tissue, and jaws. Classification therefore is made according to the radiological manifestations of the diseases and not according to etiology. (orig./MG) [de

  10. Investigating phosphonate monolayer stability on ALD oxide surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Branch, Brittany [Nanoscience and Microsystems Engineering and Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, NM 87131 (United States); Dubey, Manish [Lujan Center, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Anderson, Aaron S. [Physical Chemistry and Applied Spectroscopy, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Artyushkova, Kateryna [Nanoscience and Microsystems Engineering and Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, NM 87131 (United States); Baldwin, J. Kevin [Center for Integrated Nanotechnologies, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Petsev, Dimiter [Nanoscience and Microsystems Engineering and Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, NM 87131 (United States); Dattelbaum, Andrew M., E-mail: amdattel@lanl.gov [Center for Integrated Nanotechnologies, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2014-01-01

    We report a series of studies aimed at investigating the stability of phosphonate self-assembled monolayers (SAMs) made from octadecylphosphonic acid (ODPA) or a perfluorinated phosphonic acid (PFPA) on hafnium and aluminum oxide surfaces deposited by atomic layer deposition (ALD). The monolayers were deposited by a series of techniques including self-assembly from solution, tethering by aggregation and growth, and the Langmuir–Blodgett (LB) method. SAMs prepared by LB method were primarily used in our stability investigations because they were found to be the most uniform and reproducible. All films deposited on ALD oxide-coated substrates were characterized by means of water contact angle measurements, spectroscopic ellipsometry, X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). XPS data conclusively showed covalent phosphonate formation on both substrates. SAMs formed on both Al{sub 2}O{sub 3} and HfO{sub 2} were stable upon exposure to water. PFPA SAMs on HfO{sub 2} were found to be the most stable SAMs studied here in either water or phosphate buffer (PBS) at room temperature. We also show that similar silane-based SAMs made from octadecyltrichlorosilane (OTS) on silicon oxide (SiO{sub 2}) are less stable in PBS than phosphonate SAMs on atomic layer deposited HfO{sub 2} substrates. These data suggest that phosphonate SAMs should be considered for use in (bio)molecular sensing and actuator devices that utilize ALD and require longer-term stability under aqueous conditions.

  11. Effects of decontamination solutions on the surface of titanium: investigation of surface morphology, composition, and roughness.

    Science.gov (United States)

    Wheelis, Sutton E; Gindri, Izabelle M; Valderrama, Pilar; Wilson, Thomas G; Huang, Jessica; Rodrigues, Danieli C

    2016-03-01

    To investigate the impact of treatments used to detoxify dental implants on the oxide layer morphology and to infer how changes in morphology created by these treatments may impact re-osseointegration of an implant. Pure titanium (cpTi) and the alloy Ti6Al4V were subjected to a series of chemical treatments and mechanical abrasion simulating surface decontamination of dental implants. The morphology and roughness of the surface layer before and after treatment with these solutions were investigated with optical and atomic force microscopy (OM, AFM). The solutions employed are typically used for detoxification of dental implants. These included citric acid, 15% hydrogen peroxide, chlorhexidine gluconate, tetracycline, doxycycline, sodium fluoride, peroxyacetic acid, and treatment with carbon dioxide laser. The treatments consisted of both immersions of samples in solution and rubbing with cotton swabs soaked in solution for 1, 2, and 5 min. Cotton swabs used were analyzed with energy dispersive spectroscopy (EDS). The microscopy investigation showed that corrosion and pitting of the samples were present in both metal grades with immersion and rubbing methods when employing more acidic solutions, which had pH acidic solutions caused surface discoloration when coupled with rubbing but did not cause corrosion with immersion. Neutral or basic treatments resulted in no signs of corrosion with both methods. EDS results revealed the presence of titanium particles on all rubbing samples. It was demonstrated in this study that acidic environments coupled with rubbing are able to introduce noticeable morphological changes and corrosion on the surface of both titanium grades. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. CORROSION AND SURFACE PROTECTION IN MACHINE MATERIALS FRICTION HAVE DIFFERENT SURFACE PAIRS EXPERIMENTAL INVESTIGATION OF FACTORS

    Directory of Open Access Journals (Sweden)

    Senai YALCINKAYA

    2017-05-01

    Full Text Available Friction force, normal force, linear change. The normal force varies with the loads on the friction object. In order to determine the friction force and the friction coefficient, the friction object and the friction speed are used. The experimental work was carried out in three stages. In the first stage, the effect of normal force on the friction force was studied. In the second step, the friction force of the friction surface area is influenced. The effect of the change of the shear rate in step 3 on the friction force was investigated. At the last stage, the experimental study of the effect of the material selection on the friction force was made and it was seen that the aluminum / brass surface pair had the smallest friction coefficient as a result of the opening. The greatest coefficient of friction is found in the pair of glass / felt objects.

  13. Rational use of diagnostic radiology

    International Nuclear Information System (INIS)

    Racoveanu, N.T.; Volodin, V.

    1992-01-01

    Radiologists in USA and UK have since early 1970 questioned the efficacy of various radiological investigations and produced substantial evidence that more rational approaches are necessary. WHO initiated, in 1977, a programme which has issued four technical reports giving practical recommendations on how to rationalise the use of radiological examinations. Three main directions are considered: (1) Abandonment of routine radiological examinations, as procedures with no clinical or epidemiologic significance and which represent a waste of resources and patient dose. (2) Patient selection for various radiological investigations based on clinical criteria (high, intermediate, low yield). Selected patients have an increased prevalence of the given disease and the predictive value of radiological investigation is much higher. (3) Use of diagnostic algorithms with higher cost/efficiency and risk/benefit ratios, improving the outcome of radiological examinations. (author)

  14. Radiological colpocephaly

    International Nuclear Information System (INIS)

    Landman, J.; Dulitzki, F.; Sirota, L.; Aloni, D.; Bar-Ziv, J.; Weitz, R.; Shuper, A.; Gadoth, N.

    1989-01-01

    The term colpocephaly, meaning disproportional enlargement of the occipital horns of the lateral ventricles, was considered in the past to be a distinct congenital malformation acquired in early intrauterine life. During the last few years several causes were reported in whom a variety of intrauterine and perinatal causes could be associated with this radiological picture. We report on 9 children with radiological colpocephaly in whom intrauterine and/or perinatal injury to the developing brain seemed to be the cause of colpocephaly. It is evident from our observations that 'radiological colpocephaly' is a non-specific finding caused frequently by CNS damage acquired during intrauterine and perinatal life. (author)

  15. Surface plasmon resonance of Ag organosols: Experimental and theoretical investigations

    Directory of Open Access Journals (Sweden)

    Vodnik Vesna

    2012-01-01

    Full Text Available The aim of this paper is to investigate and compare the changes in surface plasmon resonance (SPR of silver (Ag hydrosol and organosols obtained by experimental and theoretical approaches. Silver nanoparticles (Ag NPs of 5 ± 1.5 nm in diameter were prepared in water by reduction of silver nitrate with sodium borohydride. Nanoparticles were subsequently transferred into different organic solvents (chloroform, hexane, toluene, 1,2-dichlorobenzene using oleylamine as a transfer agent. These solvents were chosen because of the differences in their refractive indices. Using UV-Vis absorption spectrophotometry and transmission electron microscopy (TEM, we confirmed that there were no shape and size changes of the nanoparticles upon the transfer to the organic phase. The absorption spectra of the obtained Ag organosols showed only changes in the position of SPR band depending on dielectric property of the used solvent. To analyze these changes, absorption spectra were modelled using Mie theory for small spherical particles. The experimental and theoretical resonance values were compared with those predicted by Drude model and its limitations in the analysis of absorption behavior of Ag NPs in organic solvents were briefly discussed.

  16. Radiological assessment and optimization

    International Nuclear Information System (INIS)

    Zeevaert, T.; Sohier, A.

    1998-01-01

    The objectives of SCK-CEN's research in the field of radiological assessment and optimization are (1) to implement ALARA principles in activities with radiological consequences; (2) to develop methodologies for radiological optimization in decision-aiding; (3) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (4) to develop methods and programmes to assist decision-makers during a nuclear emergency; (5) to support the policy of radioactive waste management authorities in the field of radiation protection; (6) to investigate computer codes in the area of multi criteria analysis; (7) to organise courses on off-site emergency response to nuclear accidents. Main achievements in these areas for 1997 are summarised

  17. Radiological assessment and optimization

    Energy Technology Data Exchange (ETDEWEB)

    Zeevaert, T.; Sohier, A

    1998-07-01

    The objectives of SCK-CEN's research in the field of radiological assessment and optimization are (1) to implement ALARA principles in activities with radiological consequences; (2) to develop methodologies for radiological optimization in decision-aiding; (3) to improve methods to assess in real time the radiological hazards in the environment in case of an accident; (4) to develop methods and programmes to assist decision-makers during a nuclear emergency; (5) to support the policy of radioactive waste management authorities in the field of radiation protection; (6) to investigate computer codes in the area of multi criteria analysis; (7) to organise courses on off-site emergency response to nuclear accidents. Main achievements in these areas for 1997 are summarised.

  18. Investigation of Floor Surface Finishes for Optimal Slip Resistance Performance

    Directory of Open Access Journals (Sweden)

    In-Ju Kim

    2018-03-01

    Full Text Available Background: Increasing the slip resistance of floor surfaces would be desirable, but there is a lack of evidence on whether traction properties are linearly correlated with the topographic features of the floor surfaces or what scales of surface roughness are required to effectively control the slipperiness of floors. Objective: This study expands on earlier findings on the effects of floor surface finishes against slip resistance performance and determines the operative ranges of floor surface roughness for optimal slip resistance controls under different risk levels of walking environments. Methods: Dynamic friction tests were conducted among three shoes and nine floor specimens under wet and oily environments and compared with a soapy environment. Results: The test results showed the significant effects of floor surface roughness on slip resistance performance against all the lubricated environments. Compared with the floor-type effect, the shoe-type effect on slip resistance performance was insignificant against the highly polluted environments. The study outcomes also indicated that the oily environment required rougher surface finishes than the wet and soapy ones in their lower boundary ranges of floor surface roughness. Conclusion: The results of this study with previous findings confirm that floor surface finishes require different levels of surface coarseness for different types of environmental conditions to effectively manage slippery walking environments. Collected data on operative ranges of floor surface roughness seem to be a valuable tool to develop practical design information and standards for floor surface finishes to efficiently prevent pedestrian fall incidents. Keywords: floor surface finishes, operational levels of floor surface roughness, slip resistance, wet, soapy and oily environments

  19. An investigation into design of fair surfaces over irregular domains ...

    Indian Academy of Sciences (India)

    Design of fair surfaces over irregular domains is a fundamental problem in computer-aided geometric design (CAGD), and has applications in engineering sciences (in aircraft, automobile, ship science etc.). In the design of fair surfaces over irregular domains defined over scattered data, it was widely accepted till recently ...

  20. Investigation of Tooling for Anisotropic Optical Functional Surfaces

    DEFF Research Database (Denmark)

    Li, Dongya; Regi, Francesco; Zhang, Yang

    is assessed by processing the images obtained from a digital microscope Hirox RH-2000 [1]. Figure 1 illustrates the studied surface structure and the microscope. The optical axis of microscope can be tilted within 90 degrees from the horizontal level, which simulates the viewing angle; the analysed surface...

  1. An investigation into design of fair surfaces over irregular domains ...

    Indian Academy of Sciences (India)

    neering sciences (in aircraft, automobile, ship science etc.). In the design of fair surfaces over ... In this paper, we discuss a method for construction of C1 piecewise polynomial parametric fair ... of applying the construction of piecewise polynomial parametric surfaces which interpolate prescribed 3 scattered data using ...

  2. Investigation of Surface Phenomena in Shocked Tin in Converging Geometry

    Energy Technology Data Exchange (ETDEWEB)

    Rousculp, Christopher L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Oro, David Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Margolin, Len G. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Griego, Jeffrey Randall [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reinovsky, Robert Emil [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Turchi, Peter John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-08-06

    There is great interest in the behavior of the free surface of tin under shock loading. While it is known that meso-scale surface imperfections can seed the Richtmyer-Meshkov Instability (RMI) for a surface that is melted on release, much less is known about a tin surface that is solid, but plastically deforming. Here material properties such as shear and yield strength come into play especially in converging geometry. Previous experiments have been driven by direct contact HE. Usually a thin, flat target coupon is fielded with various single-mode, sinusoidal, machined, profiles on the free surface. The free surface is adjacent to either vacuum or an inert receiver gas. Most of these previous driver/target configurations have been nominal planer geometry. With modern HE it has been straightforward to shock tin into melt on release. However it has been challenging to achieve a low enough pressure for solid state on release. Here we propose to extend the existing base of knowledge to include the behavior of the free surface of tin in cylindrical converging geometry. By shock loading a cylindrical tin shell with a magnetically driven cylindrical liner impactor, the free surface evolution can be diagnosed with proton radiography. With the PHELIX capacitor bank, the drive can easily be varied to span the pressure range to achieve solid, mixed, and liquid states on release.

  3. Investigation of Surface Phenomena in Shocked Tin in Converging Geometry

    Energy Technology Data Exchange (ETDEWEB)

    Rousculp, Christopher L. [Los Alamos National Laboratory; Oro, David Michael [Los Alamos National Laboratory; Griego, Jeffrey Randall [Los Alamos National Laboratory; Turchi, Peter John [Los Alamos National Laboratory; Reinovsky, Robert Emil [Los Alamos National Laboratory; Bradley, Joseph Thomas [Los Alamos National Laboratory; Cheng, Baolian [Los Alamos National Laboratory; Freeman, Matthew Stouten [Los Alamos National Laboratory; Patten, Austin Randall [Los Alamos National Laboratory

    2016-03-21

    There is great interest in the behavior of the free surface of tin under shock loading. While it is known that meso-scale surface imperfections can seed the Richtmyer- Meshkov Instability (RMI) for a surface that is melted on release, much less is known about a tin surface that is solid, but plastically deforming. Here material properties such as shear and yield strength come into play especially in converging geometry. Previous experiments have been driven by direct contact HE. Usually a thin, flat target coupon is fielded with various single-mode, sinusoidal, machined, profiles on the free surface. The free surface is adjacent to either vacuum or an inert receiver gas. Most of these previous driver/target configurations have been nominal planer geometry. With modern HE it has been straightforward to shock tin into melt on release. However it has been challenging to achieve a low enough pressure for solid state on release. Here we propose to extend the existing base of knowledge to include the behavior of the free surface of tin in cylindrical converging geometry. By shock loading a cylindrical tin shell with a magnetically driven cylindrical liner impactor, the free surface evolution can be diagnosed with proton radiography. With the PHELIX capacitor bank, the drive can easily be varied to span the pressure range to achieve solid, mixed, and liquid states on release. A conceptual cylindrical liner and target is shown in Figure 1.

  4. Investigation into Cherenkov light scattering and refraction on aerogel surface

    Science.gov (United States)

    Barnyakov, A. Yu.; Barnyakov, M. Yu.; Bobrovnikov, V. S.; Buzykaev, A. R.; Danilyuk, A. F.; Katcin, A. A.; Kirilenko, P. S.; Kononov, S. A.; Korda, D. V.; Kravchenko, E. A.; Kudryavtsev, V. N.; Kuyanov, I. A.; Onuchin, A. P.; Ovtin, I. V.; Podgornov, N. A.; Predein, A. Yu.; Prisekin, V. G.; Protsenko, R. S.; Shekhtman, L. I.

    2017-12-01

    The work concerns the development of aerogel radiators for RICH detectors. Aerogel tiles with a refractive index of 1.05 were tested with a RICH prototype on the electron beam on the VEPP-4M collider. It has been shown that polishing with silk tissue yields good surface quality, the amount of light loss at this surface being about 5-7%. The Cherenkov angle resolution was measured for a tile in two conditions: with a clean exit face and with a polished exit face. The number of photons detected was 13.3 and 12.7 for the clean and polished surfaces, respectively. The Cherenkov angle resolution for the polished surface is 55% worse, which can be explained with the forward scattering on the polished surface. A tile with a crack inside was also tested. The experimental data show that the Cherenkov angle resolution is the same for tracks crossing the crack area and in a crack-free area.

  5. Investigative report, science committee of Aggregate corporation Radiological technologist society of the Oita prefecture. Questionnaires research on security control of department of radiological technology of medical facilities in the Oita prefecture. The second report. Research on high risk incident measures

    International Nuclear Information System (INIS)

    Eto, Yoshihiro; Mano, Isao; Takagi, Ikuya; Murakami, Yasunori; Sueyoshi, Seiji; Yoshimoto, Asahi

    2007-01-01

    Oita association of radiological technologists carried out the questionnaires about the measures against high lisk incidental in department of radiological technology at the medical facilities in Oita. We distributed the questionnaire to 102 facilities, which are worked by the technologists (member), and got response from 91 facilities (89%). Research contents are Patient verification method'' ''Input and verification of patient attribute'' ''Infection in hospital'' ''Stumbles and falls of patient'' Contrast enhancement CT'' ''Something related to pacemaker'' ''MRI inspection and the magnetic substance'' ''Remedy mistake'' and ''Risk management''. The Result, Low level recognition contents of medical accident measures are ''Contrast enhancement CT'' ''Stumbles and falls of patient'' Risk management of department of radiological technology''. (author)

  6. Experimental and Theoretical Investigations of Glass Surface Charging Phenomena

    Science.gov (United States)

    Agnello, Gabriel

    Charging behavior of multi-component display-type (i.e. low alkali) glass surfaces has been studied using a combination of experimental and theoretical methods. Data obtained by way of a Rolling Sphere Test (RST), streaming/zeta potential and surface energy measurements from commercially available display glass surfaces (Corning EAGLE XGRTM and Lotus(TM) XT) suggest that charge accumulation is highly dependent on surface treatment (chemical and/or physical modification) and measurement environment, presumably through reactionary mechanisms at the surface with atmospheric moisture. It has been hypothesized that water dissociation, along with the corresponding hydroxylation of the glass surface, are important processes related to charging in glass-metal contact systems. Classical Molecular Dynamics (MD) simulations, in conjunction with various laboratory based measurements (RST, a newly developed ElectroStatic Gauge (ESG) and Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS)) on simpler Calcium AluminoSilicate (CAS) glass surfaces were used to further explore these phenomena. Analysis of simulated high-silica content (≥50%) (CAS) glass structures suggest that controlled variation of bulk chemistry can directly affect surface defect concentrations, such as non-bridging oxygen (NBO), which can be suitable high-energy sites for hydrolysis-type reactions to occur. Calculated NBO surface concentrations correlate well with charge based measurements on laboratory fabricated CAS surfaces. The data suggest that a directional/polar shift in contact-charge transfer occurs at low silica content (≤50%) where the highest concentrations of NBOs are observed. Surface charging sensitivity with respect to NBO concentration decreases as the relative humidity of the measurement environment increases; which should be expected as the highly reactive sites are progressively covered by liquid water layers. DRIFTS analysis of CAS powders expand on this analysis showing

  7. Integrating the Radiology Information System with Computerised Provider Order Entry: The Impact on Repeat Medical Imaging Investigations.

    Science.gov (United States)

    Vecellio, Elia; Georgiou, Andrew

    2016-01-01

    Repeat and redundant procedures in medical imaging are associated with increases in resource utilisation and labour costs. Unnecessary medical imaging in some modalities, such as X-Ray (XR) and Computed Tomography (CT) is an important safety issue because it exposes patients to ionising radiation which can be carcinogenic and is associated with higher rates of cancer. The aim of this study was to assess the impact of implementing an integrated Computerised Provider Order Entry (CPOE)/Radiology Information System (RIS)/Picture Archiving and Communications System (PACS) system on the number of XR and CT imaging procedures (including repeat imaging requests) for inpatients at a large metropolitan hospital. The study found that patients had an average 0.47 fewer XR procedures and 0.07 fewer CT procedures after the implementation of the integrated system. Part of this reduction was driven by a lower rate of repeat procedures: the average inpatient had 0.13 fewer repeat XR procedures within 24-hours of the previous identical XR procedure. A similar decrease was not evident for repeat CT procedures. Reduced utilisation of imaging procedures (especially those within very short intervals from the previous identical procedure, which are more likely to be redundant) has implications for the safety of patients and the cost of medical imaging services.

  8. Investigations on ion-beam induced desorption from cryogenic surfaces

    International Nuclear Information System (INIS)

    Maurer, Christoph

    2017-01-01

    A central component of FAIR, the Facility for Antiproton and Ion Research, will be the superconducting heavy ion synchrotron SIS100, which is supposed to provide reliable, high intensity beams for various applications. Its beam intensity is governed by the space charge limit, while the maximum energy is determined by the machine's magnetic rigidity. That means, ions with higher charge state can be accelerated to a higher energy, but with less intensity. For highest intensity beams, intermediate charge states have to be used instead of high charge state ions. This alleviates the issue of space charge but gives rise to dynamic vacuum effects, which also limit beam intensity: beam particles collide with residual gas particles, which leads to charge exchange and their subsequent loss. Impacting on the chamber wall, these ions release adsorbed gas particles. This process is called desorption and leads to a localized increase in pressure, which in turn causes more charge exchange. After a few rounds of self amplification, this can lead to total beam loss. This ''runaway-desorption'' is typically the main beam intensity limiting process for intermediate charge state (heavy) ion beams. The extent of this phenomenon is governed by two factors: the initial beam intensity and the desorption yield. The latter is examined within the scope of this thesis. Special emphasis is placed on the influence of the target's temperature, since the SIS100 will be a superconducting machine with cryogenic vacuum chamber walls. In order to investigate this topic, an experimental setup has been devised, built at the SIS18 and taken into commission. Based on the experience gained during operation, it has been continuously improved and extended. Another central innovation presented in this thesis is the use of gas dynamics simulations for an improved method of data analysis. Using this technique, environmental conditions like the chamber geometry and the connected

  9. Investigation of Vacuum Insulator Surface Dielectric Strength with Nanosecond Pulses

    International Nuclear Information System (INIS)

    Nunnally, W.C.; Krogh, M.; Williams, C.; Trimble, D.; Sampayan, S.; Caporaso, G.

    2003-01-01

    The maximum vacuum insulator surface dielectric strength determines the acceleration electric field gradient possible in a short pulse accelerator. Previous work has indicated that higher electric field strengths along the insulator-vacuum interface might be obtained as the pulse duration is decreased. In this work, a 250 kV, single ns wide impulse source was applied to small diameter, segmented insulators samples in a vacuum to evaluate the multi-layer surface dielectric strength of the sample construction. Resonances in the low inductance test geometry were used to obtain unipolar, pulsed electric fields in excess of 100 MV/m on the insulator surface. The sample construction, experimental arrangement and experimental results are presented for the initial data in this work. Modeling of the multi-layer structure is discussed and methods of improving insulator surface dielectric strength in a vacuum are proposed

  10. Tribological investigations of surface treated Ti6Al4V

    International Nuclear Information System (INIS)

    Rueck, D.M.; Schminke, A.; Schmidt, H.; Soltani-Farshi, M.; Baumann, H.; Fink, U.; Richter, E.

    1998-05-01

    The tribological couple of the titanium alloy Ti6Al4V and ultrahigh molecular weight polyethylene (UHMWPE) is used for hip and knee joint prostheses. It is known that surface treatment of the titanium alloy Ti6Al4V by ion implantation of various elements can improve the wear behavior of such prostheses. The results of tribological tests, performed in Ringer solution with a ring-on-disc tester, show that oxygen in the implanted near surface region has a pronounced influence on the wear performance. Oxygen can be introduced into the surface by different mechanisms: either by direct implantation of oxygen ions or by indiffusion during the implantation of other elements like nitrogen or carbon at higher temperatures. The influence of the oxygen content in the near surface region of implanted and nonimplanted Ti6Al4V on the tribological performance is discussed in detail. (orig.)

  11. Surface structure investigations using noncontact atomic force microscopy

    International Nuclear Information System (INIS)

    Kolodziej, J.J.; Such, B.; Goryl, M.; Krok, F.; Piatkowski, P.; Szymonski, M.

    2006-01-01

    Surfaces of several A III B V compound semiconductors (InSb, GaAs, InP, InAs) of the (0 0 1) orientation have been studied with noncontact atomic force microscopy (NC-AFM). Obtained atomically resolved patterns have been compared with structural models available in the literature. It is shown that NC-AFM is an efficient tool for imaging complex surface structures in real space. It is also demonstrated that the recent structural models of III-V compound surfaces provide a sound base for interpretation of majority of features present in recorded patterns. However, there are also many new findings revealed by the NC-AFM method that is still new experimental technique in the context of surface structure determination

  12. Investigation of surface roughness influence on hyperbolic metamaterial performance

    Directory of Open Access Journals (Sweden)

    S. Kozik

    2014-12-01

    Full Text Available The main goal of this work was to introduce simple model of surface roughness which does not involve objects with complicated shapes and could help to reduce computational costs. We described and proved numerically that the influence of surface roughness at the interfaces in metal-dielectric composite materials could be described by proper selection of refractive index of dielectric layers. Our calculations show that this model works for roughness with RMS value about 1 nm and below.

  13. Preliminary site characterization radiological monitoring plan for the Nevada Nuclear Waste Storage Investigations Project, Yucca Mountain Site

    International Nuclear Information System (INIS)

    1987-03-01

    The activities described in this plan occur in the early phases of site characterization. This document presents the Preliminary Site Characterization Radiological Monitoring Plan (PSCRMP) for collecting and evaluating data in support of the NNWSI Project. The PSCRMP defines and identifies control procedures for the monitoring activities. The PSCRMP activity will utilize integrating radon monitoring devices, a continuous radon monitor, and a particulate air sampler. These instruments will be used to establish the baseline radioactivity and/or radioactivity released due to early site characterization activities. The sections that follow provide a general project description, the specifics of the monitoring program, and the practices that will be employed to ensure the validity of the collected data by integrating quality assurance into all activities. Section 2 of this document describes the regulatory base of this document. Section 3 describes the site characterization activities which may lead to release of radioactivity. Section 4 provides a description of the potential sources of radioactivity that site characterization could generate. Section 5 summarizes the sampling and monitoring methodology, which will be used to monitor the potential sources of radioactivity. The network of sampling and monitoring equipment is described in Section 6, and Section 7 summarizes the systems operation activities. The data reporting activities are described in Section 8. Finally, a description of the Quality Assurance (QA) and Quality Control (QC) activities is provided in Section 9. Appendix A contains a summary of the procedures to be used in this program, and Appendix B contains technical specification on equipment and services. 20 refs., 11 figs., 2 tabs

  14. Post-remediation action radiological report for Surface Impoundments C (3539) and D (3540) at the Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-12-01

    During August and September 1998, Bechtel Jacobs Company LLC performed a remedial action within Impoundments 3539 and 3540 (Impoundments C and D, respectively) in accordance with the Comprehensive Environmental Response, Compensation, and Liability Act Record of Decision (ROD) for the Surface Impoundments Operable Unit. The remedial action included removal of sediments and 0.1 ft of subimpoundment soil. A post-remedial action radiological survey was conducted to provide data to support the Bethel Valley ROD. Data was obtained from (1) a walkover survey for residual gamma radiation on the base of the impoundments, (2) smear surveys for transferable contamination on remaining riprap, and (3) representative sampling of subimpoundment soils. Walkover surveys identified no locations outside the impoundments with gamma exposure levels greater than three times background levels. Smear surveys detected no removable contamination above release limits as specified in 10 CFR 835, Appendix D. Subimpoundment soil samples quantified low levels of residual contamination

  15. Post-remediation action radiological report for Surface Impoundments C (3539) and D (3540) at the Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-01

    During August and September 1998, Bechtel Jacobs Company LLC performed a remedial action within Impoundments 3539 and 3540 (Impoundments C and D, respectively) in accordance with the Comprehensive Environmental Response, Compensation, and Liability Act Record of Decision (ROD) for the Surface Impoundments Operable Unit. The remedial action included removal of sediments and 0.1 ft of subimpoundment soil. A post-remedial action radiological survey was conducted to provide data to support the Bethel Valley ROD. Data was obtained from (1) a walkover survey for residual gamma radiation on the base of the impoundments, (2) smear surveys for transferable contamination on remaining riprap, and (3) representative sampling of subimpoundment soils. Walkover surveys identified no locations outside the impoundments with gamma exposure levels greater than three times background levels. Smear surveys detected no removable contamination above release limits as specified in 10 CFR 835, Appendix D. Subimpoundment soil samples quantified low levels of residual contamination.

  16. Investigations of the surface resistance of superconducting materials

    International Nuclear Information System (INIS)

    Junginger, Tobias

    2012-01-01

    In particle accelerators superconducting RF cavities are widely used to achieve high accelerating gradients and low losses. Power consumption is proportional to the surface resistance R S which depends on a number of external parameters, including frequency, temperature, magnetic and electric field. Presently, there is no widely accepted model describing the increase of R S with applied field. In the frame of this project the 400 MHz Quadrupole Resonator has been extended to 800 and 1200 MHz to study surface resistance and intrinsic critical RF magnetic field of superconducting samples over a wide parameter range, establishing it as a world-wide unique test facility for superconducting materials. Different samples were studied and it was shown that R S is mainly caused by the RF electric field in the case of strongly oxidized surfaces. This can be explained by interface tunnel exchange of electrons between the superconductor and localized states in adjacent oxides. For well prepared surfaces, however, the majority of the dissipation is caused by the magnetic field and R S factorizes into field and temperature dependent parts. These different loss mechanisms were correlated to surface topography of the samples and distribution of oxides by using ultrasonic force microscopy and X-ray photon spectroscopy.

  17. AFM surface morphology investigation of ion beam modified polyimide

    Science.gov (United States)

    Švorčík, V.; Arenholz, E.; Rybka, V.; Hnatowicz, V.

    1997-03-01

    Polyimide Upilex R was irradiated with 90 keV N + ions to the fluences of 1 × 10 14-2 × 10 17 cm -2. The surface morphology and the structure of the ion beam modified PI were examined using atomic force microscopy and X-ray difraction. Sheet resistance as a function of the ion fluence and the sample temperature was measured by standard two point technique. Significant changes of the surface morphology and production of graphitic phase in the sample surface layer modified by the ion irradiation were observed. Strong decrease of the sheet resistance (by 11 orders of magnitude) in the ion beam modified samples is connected with progressive carbonization and graphitization of the degraded polymer. Electrical charge transport is mediated by variable-range hopping mechanism. Drastic structural changes initiated by the ion irradiation to high fluences are similar to those observed in polymer pyrolysis.

  18. An investigation into design of fair surfaces over irregular domains ...

    Indian Academy of Sciences (India)

    Surface interpolation to scattered data in 3 is a problem of general interest cutting across many engineering .... As per Lawson (1977) and Renka (1984), there is a unique piecewise cubic function s1 in. C1 (T ) which .... integration techniques to evaluate the quadratic energy integral, and both of these are com- putationally ...

  19. Investigation on the micromilled surface characterization through replica technology

    DEFF Research Database (Denmark)

    Baruffi, Federico; Parenti, P.; Cacciatore, F.

    2016-01-01

    with quality control and tolerances to meet the parts functionality. However, in many cases, the reduced accessibility caused by the part complex features (e.g. microcavities, micro-holes, deep-cores) prevents from performing a direct measurement of the surface, using both contactand non-contact techniques...

  20. Investigations of surface characterization of silicone rubber due to ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. In the present work, tracking phenomena has been studied with silicone rubber material under the. a.c. and d.c. voltages following IEC-587 standards. The surface condition of the tracked zone was analysed using wide angle X-ray diffraction (WAXD) and thermogravimetric differential thermal analysis (TG–DTA).

  1. Investigation on surface composition of ancient sham mirrors

    International Nuclear Information System (INIS)

    Li Daolun; Wei Chenglian; Fan Qinmin; Liu Yawen; Li Huhou

    1989-01-01

    A systematic comparison between the Han Dynasty mirror and the shams on composition, homogeneity and impurities for both sides has been made. The experimental results show that Sn content on the surface of the shams is lower, and impurities are higher than those of the Han Dynasty mirror, which is useful to distinguish the sham from the genuine

  2. A model investigation of annual surface ultraviolet radiation in Iran

    International Nuclear Information System (INIS)

    Sabziparvar, A.-A.

    2003-01-01

    In recent years, there has been some concern regarding solar ultraviolet (UV) radiation received at the earth,s surface because of its biological hazards affecting living organisms. Although the geographical distribution of ground-based UV network is relatively good in some continents,but over Asia, the number of UV instruments are not sufficient for meteorological and biological purposes. Iran, as an Asian country, is also suffering from the lack of UV monitoring network with the exception of one ground-based UV spectrophotometer site (Brower III) at Esfahan. Using a complex radiative transfer model and various meteorological data (for 8 years) such as total column ozone, cloudiness, surface albedo, surface air pressure, relative humidity, visibility and daily total solar radiation (TSR), the geographical distribution of annual integrated biological surface UV irradiances such as UVB, erythema and cataracts are calculated. The comparison is made for cloud-free and all-sky conditions for eight selected cities distributed from the southern tip of the country (25 N-60 E) to the northern border (39 N-48 E). It is shown that the difference between the annual UV at south and north in all-sky condition is larger than the differences in cloud-free condition. The ratio of some biological UV irradiances at southern cities to the same component at northern cities shows a factor of two and more which is quite significant. The possible reasons which might cause such differences are discussed

  3. Investigation into the origin of the noise of surface electrodes

    NARCIS (Netherlands)

    Huigen, E.; Peper, A.; Grimbergen, C. A.

    2002-01-01

    In the recording of biomedical signals, a significant noise component is introduced by the electrode. The magnitude of this noise is considerably higher than the equivalent thermal noise from the electrode impedance. As the noise in surface electrodes limits the resolution of biopotential

  4. Investigations Of Powder Surface Properties Of Drug Substances ...

    African Journals Online (AJOL)

    In this study, Inverse Gas Chromatography (IGC) was used to characterize the surface energetics of different batches of two drug substances (Salmetrol Xinafoate, SX and Fluticasone Propionate, FP) manufactured under identical conditions. The results obtained demonstrate the potential of IGC technique to reveal ...

  5. The effect of extent of site investigation on the estimation of radiological performance and its relevance to the proposed Rock Characterisation Facility at Sellafield

    International Nuclear Information System (INIS)

    Mackay, R.

    1996-01-01

    Proof of Evidence is given by an expert witness on behalf of Greenpeace Ltd as part of their submission to a Planning Inquiry in 1995 hearing the application of UK Nirex Ltd for permission to construct an underground Rock Characterisation Facility (RCF) at a site near Sellafield. The RCF is part of an investigation by Nirex into a suitable site for the disposal of radioactive waste. The evidence concerns the necessity of establishing an adequate hydrogeological model of the site in advance of the construction of the RCF in order to estimate its radiological performance. This detailed examination of Nirex's approach concludes that it is not apparent that a method for demonstrating the adequacy of the conceptual hydrogeological model has been clearly and openly stated so that it may be agreed in advance of construction with an appropriate authority. (1 figure; 1 table, 12 references). (UK)

  6. Arecibo Radar Investigations of Planetary and Small-Body Surfaces

    Science.gov (United States)

    Taylor, P. A.

    2016-12-01

    The 305-m William E. Gordon telescope at Arecibo Observatory in Puerto Rico is the most sensitive, most powerful, and most active planetary radar facility in the world. Over the last 50-plus years, the S-band (12.6 cm, 2380 MHz) and P-band (70 cm, 430 MHz) radars at Arecibo have studied solid bodies in the solar system from Mercury to Saturn's rings. Radar provides fine spatial resolution of these bodies surpassed only by dedicated spacecraft while adding the extra dimensions of near-surface, wavelength-scale roughness and penetration to several wavelengths below the surface. For asteroids and comets, this spatial resolution is akin to a spacecraft flyby revealing spin, size, and shape information and geologic features such as ridges, crater-like depressions, and boulders. For planetary bodies, radar can reveal geologic features on the surface such as ancient lava flows or features buried beneath the regolith including lava tubes and water-ice deposits. We will present an overview of how the Arecibo radar systems are utilized in the study of planetary and small-body surfaces and what can be learned without ever leaving the comfort of Earth's surface. The Arecibo Observatory is operated by SRI International under a cooperative agreement with the National Science Foundation (AST-1100968) and in alliance with Ana G. Mendez-Universidad Metropolitana (UMET) and the Universities Space Research Association (USRA). The Arecibo Planetary Radar Program is supported by the National Aeronautics and Space Administration under Grant Nos. NNX12AF24G and NNX13AQ46G issued through the Near-Earth Object Observations program and operated by USRA in alliance with SRI International and UMET.

  7. Investigations of the Band Structure and Morphology of Nanostructured Surfaces

    Science.gov (United States)

    Knox, Kevin R.

    2011-12-01

    In this dissertation, I examine the electronic structure of two very different types of two-dimensional systems: valence band electrons in single layer graphene and electronic states created at the vacuum interface of single crystal copper surfaces. The characteristics of both electronic systems depend intimately on the morphology of the surfaces they inhabit. Thus, in addition to discussing the respective band structures of these systems, a significant portion of this dissertation will be devoted to measurements of the surface morphology of these systems. Free-standing exfoliated monolayer graphene is an ultra-thin flexible membrane and, as such, is known to exhibit large out-of-plane deformation due to substrate and adsorbate interaction as well as thermal vibrations and, possibly, intrinsic buckling. Such crystal deformation is known to limit mobility and increase local chemical reactivity. Additionally, deformations present a measurement challenge to researchers wishing to determine the band structure by angle-resolved photoemission since they limit electron coherence in such measurements. In this dissertation, I present low energy electron microscopy and micro probe diffraction measurements, which are used to image and characterize corrugation in SiO2-supported and suspended exfoliated graphene at nanometer length scales. Diffraction line-shape analysis reveals quantitative differences in surface roughness on length scales below 20 nm which depend on film thickness and interaction with the substrate. Corrugation decreases with increasing film thickness, reflecting the increased stiffness of multilayer films. Specifically, single-layer graphene shows a markedly larger short range roughness than multilayer graphene. Due to the absence of interactions with the substrate, suspended graphene displays a smoother morphology and texture than supported graphene. A specific feature of suspended single-layer films is the dependence of corrugation on both adsorbate load

  8. A theoretical investigation of water adsorption on titanium dioxide surfaces

    Science.gov (United States)

    Fahmi, Adil; Minot, Christian

    1994-03-01

    Water adsorption on various crystallographic faces of TiO 2 (anatase and rutile) are calculated using a periodic Hartree-Fock method. Titanium oxide is an amphoteric compound. Water adsorbs on the acidic site, the titanium atom, and then dissociates to give hydroxyl groups. The adsorption energy is larger on the (110) face of the rutile structure than on other faces and is correlated with its very acidic sites. The OH groups are oriented to maximize hydrogen bonding. Hydrogen bonding is particularly important for molecular adsorption on the (100) face of the rutile structure; in this case, the molecular adsorption becomes competitive with the dissociative one. The thermodynamics of water adsorption strongly favor dissociation when singly-coordinated oxygen atoms are present on the surface as it is in a perfectly truncated anatase surface.

  9. INVESTIGATION OF MICRO AND NANOSTRUCTURE OF HYDROPHOBIC PLANTS SURFACE

    OpenAIRE

    M. V. Zhukov

    2014-01-01

    Micro and nanostructure of petals and flowers of pink rose family having super hydrophobic phenomenon known as "lotus effect" was studied by optical and scanning probe microscopy. Quasi-ordered corrugated structure was found on the surface of the rose petals. It represents the ensemble of smoothed shape peaks like a lotus leaf structure. Structure saving during dehydration of rose petal (for 5 days) by drying in the air under normal conditions was found, the difference is apparent in the dens...

  10. The Origin of Mercury's Surface Composition, an Experimental Investigation

    Science.gov (United States)

    Boujibar, A.; Righter, K.; Rapp, J. F.; Ross, D. K.; Pando, K. M.; Danielson, L. R.; Fontaine, E.

    2016-01-01

    Introduction: Results from MESSENGER spacecraft have confirmed the reduced nature of Mercury, based on its high core/mantle ratio and its FeO-poor and S-rich surface. Moreover, high resolution images revealed large volcanic plains and abundant pyroclastic deposits, suggesting major melting stages of the Mercurian mantle. In addition, MESSENGER has provided the most precise data to date on major elemental compositions of Mercury's surface. These results revealed considerable chemical heterogeneities that suggested several stages of differentiation and re-melting processes. This interpretation was challenged by our experimental previous study, which showed a similar compositional variation in the melting products of enstatite chondrites, which are a possible Mercury analogue. However, these experimental melts were obtained over a limited range of pressure (1 bar to 1 gigapascal) and were not compared to the most recent elemental maps. Therefore, here we extend the experimental dataset to higher pressures and perform a more quantitative comparison with Mercury's surface compositions measured by MESSENGER. In particular, we test whether these chemical heterogeneities result from mixing between polybaric melts. Our experiments and models show that the majority of chemical diversity of Mercury's surface can result from melting of a primitive mantle compositionally similar to enstatite chondrites in composition at various depths and degrees of melting. The high-Mg region's composition is reproduced by melting at high pressure (3 gigapascals) (Tab. 1), which is consistent with previous interpretation as being a large degraded impact basin based on its low elevation and thin average crust. While low-Mg NVP (North Volcanic Plains) are the result of melting at low pressure (1 bar), intermediate-Mg NVP, Caloris Basin and Rachmaninoff result from mixing of a high-pressure (3 gigapascals) and low-pressure components (1 bar for Rachmaninoff and 1 gigapascal for the other regions

  11. Radiological protection in interventional radiology

    International Nuclear Information System (INIS)

    Padovani, R.

    2001-01-01

    Interventional radiology (IR) reduces the need for many traditional interventions, particularly surgery, so reducing the discomfort and risk for patients compared with traditional systems. IR procedures are frequently performed by non-radiologist physicians, often without the proper radiological equipment and sufficient knowledge of radiation protection. Levels of doses to patients and staff in IR vary enormously. A poor correlation exists between patient and staff dose, and large variations of dose are reported for the same procedure. The occurrence of deterministic effects in patients is another peculiar aspect of IR owing to the potentially high skin doses of some procedures. The paper reviews the use of IR and the radiological protection of patients and staff, and examines the need for new standards for IR equipment and the training of personnel. (author)

  12. Experimental Investigations on Microshock Waves and Contact Surfaces

    Science.gov (United States)

    Kai, Yun; Garen, Walter; Teubner, Ulrich

    2018-02-01

    The present work reports on progress in the research of a microshock wave. Because of the lack of a good understanding of the propagation mechanism of the microshock flow system (shock wave, contact surface, and boundary layer), the current work concentrates on measuring microshock flows with special attention paid to the contact surface. A novel setup involving a glass capillary (with a 200 or 300 μ m hydraulic diameter D ) and a high-speed magnetic valve is applied to generate a shock wave with a maximum initial Mach number of 1.3. The current work applies a laser differential interferometer to perform noncontact measurements of the microshock flow's trajectory, velocity, and density. The current work presents microscale measurements of the shock-contact distance L that solves the problem of calculating the scaling factor Sc =Re ×D /(4 L ) (introduced by Brouillette), which is a parameter characterizing the scaling effects of shock waves. The results show that in contrast to macroscopic shock waves, shock waves at the microscale have a different propagation or attenuation mechanism (key issue of this Letter) which cannot be described by the conventional "leaky piston" model. The main attenuation mechanism of microshock flow may be the ever slower moving contact surface, which drives the shock wave. Different from other measurements using pressure transducers, the current setup for density measurements resolves the whole microshock flow system.

  13. Surface hydrologic investigations of the Columbia Plateau Region, Washington

    International Nuclear Information System (INIS)

    Leonhart, L.S.

    1979-07-01

    The Washington State portion of the Columbia Plateau is divided into six hydrologic sub-basins on the basis of the principal surface drainage systems present, structural and topographic relationships, and political and other considerations. Baseline descriptions of the surface water systems and resources are presented for the Columbia Plateau with emphasis on the Pasco Sub-basin. A preliminary evaluation of the hydrologic budget for each sub-basin is derived. For each sub-basin, recharge/discharge relationships arising from precipitation/evapotranspiration/runoff, stream losses and gains, and artificial mechanisms are determined on the basis of available data. The net exchange between surface and groundwater systems is evaluated and relative estimates of the net groundwater flow into or out of the sub-basin are obtained. An evaluation is made of hydrologic risk factors arising from: (1) tributary flooding in eastern Washington; and, (2) major flooding of the Columbia River within the Pasco Sub-basin. Scenarios are presented for credible natural and man-generated catastrophic events

  14. Whither Radiology?

    African Journals Online (AJOL)

    15 Mei 1974 ... cess of those audible to animals. Sonar should not be confused with X-rays, which have biological effects due to the production of ionising radiation, whereas ultrasound is vibrational or mechanical energy of an ultrahigh frequency. Ultrasound has taken over from conventional radiology in quite a few ...

  15. Radiologic considerations

    International Nuclear Information System (INIS)

    Judge, L.O.

    1987-01-01

    An increasing variety of imaging modalities as well as refinements of interventional techniques have led to a resurgence of radiologic interest and participation in urolithiasis management. Judicious selection of the diagnostic examination, close monitoring during the procedure, consultation with urologic colleagues, and a careful regard for radiation safety guidelines define the role of the radiologist in renal stone disease

  16. Investigations of radioactive contamination of 'underlying surface - atmosphere' system

    International Nuclear Information System (INIS)

    Osintsev, A.Yu.; Panin, M.S.; Artem'ev, O.I.; Gaziev, Ya.I.

    2008-01-01

    In article the results of carried out field investigations of radionuclide compositions and dispersed characteristics of anthropogenic dust lifting products and organized on radioactive 'spot' on the Semipalatinsk Test Site fires are presented. Investigations were made for the purpose of parameters refinement and improvement of physico-mathematical models of air environmental pollution with aerosuspensions and aerosols from different sources them intensive entrance in the atmosphere

  17. Thermodynamics and structure of liquid surfaces investigated directly with surface analytical tools

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Gunther [Flinders Univ., Adelaide, SA (Australia). Centre for NanoScale Science and Technology; Morgner, Harald [Leipzig Univ. (Germany). Wilhelm Ostwald Inst. for Physical and Theoretical Chemistry

    2017-06-15

    Measuring directly the composition, the distribution of constituents as function of the depth and the orientation of molecules at liquid surfaces is essential for determining physicochemical properties of liquid surfaces. While the experimental tools that have been developed for analyzing solid surfaces can in principal be applied to liquid surfaces, it turned out that they had to be adjusted to the particular challenges imposed by liquid samples, e.g. by the unavoidable vapor pressure and by the mobility of the constituting atoms/molecules. In the present work it is shown, how electron spectroscopy and ion scattering spectroscopy have been used for analyzing liquid surfaces. The emphasis of this review is on using the structural information gained for determining the physicochemical properties of liquid surfaces. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. Investigation of surface properties of physico-chemically modified natural fibres using inverse gas chromatography

    CSIR Research Space (South Africa)

    Cordeiro, N

    2011-01-01

    Full Text Available Inverse gas chromatography (IGC) is a suitable method to determine surface energy of natural fibres when compared to wetting techniques. In the present study, the surface properties of raw and modified lignocellulosic fibres have been investigated...

  19. Radiological incidents in radiotherapy

    International Nuclear Information System (INIS)

    Hobzova, L.; Novotny, J.

    2008-01-01

    In many countries a reporting system of radiological incidents to national regulatory body exists and providers of radiotherapy treatment are obliged to report all major and/or in some countries all incidents occurring in institution. State Office for Nuclear Safety (SONS) is providing a systematic guidance for radiotherapy departments from 1997 by requiring inclusion of radiation safety problems into Quality assurance manual, which is the basic document for obtaining a license of SONS for handling with sources of ionizing radiation. For that purpose SONS also issued the recommendation 'Introduction of QA system for important sources in radiotherapy-radiological incidents' in which the radiological incidents are defined and the basic guidance for their classification (category A, B, C, D), investigation and reporting are given. At regular periods the SONS in co-operation with radiotherapy centers is making a survey of all radiological incidents occurring in institutions and it is presenting obtained information in synoptic communication (2003 Motolske dny, 2005 Novy Jicin). This presentation is another summary report of radiological incidents that occurred in our radiotherapy institutions during last 3 years. Emphasis is given not only to survey and statistics, but also to analysis of reasons of the radiological incidents and to their detection and prevention. Analyses of incidents in radiotherapy have led to a much broader understanding of incident causation. Information about the error should be shared as early as possible during or after investigation by all radiotherapy centers. Learning from incidents, errors and near misses should be a part of improvement of the QA system in institutions. Generally, it is recommended that all radiotherapy facilities should participate in the reporting, analyzing and learning system to facilitate the dissemination of knowledge throughout the whole country to prevent errors in radiotherapy.(authors)

  20. SNF Interim Storage Canister Corrosion and Surface Environment Investigations

    Energy Technology Data Exchange (ETDEWEB)

    Bryan, Charles R. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Enos, David G. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    This progress report describes work being done at Sandia National Laboratories (SNL) to assess the localized corrosion performance of container/cask materials used in the interim storage of spent nuclear fuel (SNF). Of particular concern is stress corrosion cracking (SCC), by which a through-wall crack could potentially form in a canister outer wall over time intervals that are shorter than possible dry storage times. In order for SCC to occur, three criteria must be met. A corrosive environment must be present on the canister surface, the metal must susceptible to SCC, and sufficient tensile stress to support SCC must be present through the entire thickness of the canister wall. SNL is currently evaluating the potential for each of these criteria to be met.

  1. Soil Radiological Characterisation Methodology

    International Nuclear Information System (INIS)

    Attiogbe, Julien; Aubonnet, Emilie; De Maquille, Laurence; De Moura, Patrick; Desnoyers, Yvon; Dubot, Didier; Feret, Bruno; Fichet, Pascal; Granier, Guy; Iooss, Bertrand; Nokhamzon, Jean-Guy; Ollivier Dehaye, Catherine; Pillette-Cousin, Lucien; Savary, Alain

    2014-12-01

    This report presents the general methodology and best practice approaches which combine proven existing techniques for sampling and characterisation to assess the contamination of soils prior to remediation. It is based on feedback of projects conducted by main French nuclear stakeholders involved in the field of remediation and dismantling (EDF, CEA, AREVA and IRSN). The application of this methodology will enable the project managers to obtain the elements necessary for the drawing up of files associated with remediation operations, as required by the regulatory authorities. It is applicable to each of the steps necessary for the piloting of remediation work-sites, depending on the objectives targeted (release into the public domain, re-use, etc.). The main part describes the applied statistical methodology with the exploratory analysis and variogram data, identification of singular points and their location. The results obtained permit assessment of a mapping to identify the contaminated surface and subsurface areas. It stakes the way for radiological site characterisation since the initial investigations from historical and functional analysis to check that the remediation objectives have been met. It follows an example application from the feedback of the remediation of a contaminated site on the Fontenay aux Roses facility. It is supplemented by a glossary of main terms used in the field from different publications or international standards. This technical report is a support of the ISO Standard ISO ISO/TC 85/SC 5 N 18557 'Sampling and characterisation principles for soils, buildings and infrastructures contaminated by radionuclides for remediation purposes'. (authors) [fr

  2. Dental radiology.

    Science.gov (United States)

    Woodward, Tony M

    2009-02-01

    Dental radiology is the core diagnostic modality of veterinary dentistry. Dental radiographs assist in detecting hidden painful pathology, estimating the severity of dental conditions, assessing treatment options, providing intraoperative guidance, and also serve to monitor success of prior treatments. Unfortunately, most professional veterinary training programs provide little or no training in veterinary dentistry in general or dental radiology in particular. Although a technical learning curve does exist, the techniques required for producing diagnostic films are not difficult to master. Regular use of dental x-rays will increase the amount of pathology detected, leading to healthier patients and happier clients who notice a difference in how their pet feels. This article covers equipment and materials needed to produce diagnostic intraoral dental films. A simplified guide for positioning will be presented, including a positioning "cheat sheet" to be placed next to the dental x-ray machine in the operatory. Additionally, digital dental radiograph systems will be described and trends for their future discussed.

  3. Genitourinary radiology

    Energy Technology Data Exchange (ETDEWEB)

    McClennan, B.L.

    1982-01-01

    A literature review of genitourinary radiology highlights new findings in the field that have occurred in the past year. The physiology of contrast media, and the occasional life-threatening contrast medial reaction are discussed. Common urologic problems such as stones, infection, and obstruction are examined in order to interpret static radiographs in a more meaningful way. The field of interventional uroradiology continues to expand, with new procedures being tried and new indications for old procedures being developed. (KRM)

  4. Chest radiology

    International Nuclear Information System (INIS)

    Reed, J.C.

    1990-01-01

    This book is a reference in plain chest film diagnosis provides a thorough background in the differential diagnosis of 22 of the most common radiologic patterns of chest disease. Each chapter is introduced with problem cases and a set of questions, followed by a tabular listing of the appropriate differential considerations. The book emphasizes plain films, CT and some MR scans are integrated to demonstrate how these modalities enhance the work of a case

  5. Investigation of plasma–surface interaction at plasma beam facilities

    Energy Technology Data Exchange (ETDEWEB)

    Kurnaev, V., E-mail: kurnaev@plasma.mephi.ru [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Kashirskoe sh. 31, 115409 Moscow (Russian Federation); Vizgalov, I.; Gutorov, K. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Kashirskoe sh. 31, 115409 Moscow (Russian Federation); Tulenbergenov, T.; Sokolov, I.; Kolodeshnikov, A.; Ignashev, V.; Zuev, V.; Bogomolova, I. [Institute of Atomic Energy, National Nuclear Center the Republic of Kazakhstan, Street Krasnoarmejsky, 10, 071100 Kurchatov (Kazakhstan); Klimov, N. [SRC RF TRINITI, ul. Pushkovykh, vladenie 12, Troitsk, 142190 Moscow (Russian Federation)

    2015-08-15

    The new Plasma Beam Facility (PBF) has been put into operation for assistance in testing of plasma faced components at Material Science Kazakhstan Tokamak (KTM). PBF includes a powerful electron gun (up to 30 kV, 1 A) and a high vacuum chamber with longitudinal magnetic field coils (up to 0.2 T). The regime of high vacuum electron beam transportation is used for thermal tests with power density at the target surface up to 10 GW/m{sup 2}. The beam plasma discharge (BPD) regime with a gas-puff is used for generation of intensive ion fluxes up to 3 ⋅ 10{sup 22} m{sup −2} s{sup −1}. Initial tests of the KTM PBF’s capabilities were carried out: various discharge regimes, carbon deposits cleaning, simultaneous thermal and ion impacts on radiation cooled refractory targets. With a water-cooled target the KTM PBF could be used for high heat flux tests of materials (validated by the experiment with W mock-up at the PR-2 PBF)

  6. Investigating the conformation of polymeric dispersant molecules on nanoparticle surface

    International Nuclear Information System (INIS)

    Yasin, S.; Luckham, P.F.; Iqbal, T

    2016-01-01

    Block copolymers are widely used as stabilizers in industrial dispersions. These polymers adsorb on surfaces by an anchor chain and extend by a hydrophilic chain. Scaling model or de Gennes theory has been used to determine the grafting density of the block copolymers. By implementing this theory to the block copolymers, conformation of the polymer molecules as a function of distance between adjacent anchor chains can be determined. The scaling model was applied to a selection of block copolymers (PE/F 103, PE/F 108, NPE1800, Triton X100, Triton X405, Lugalvan BNO12, Hypermer LP1, Hypermer B246 and OLOA 11000) in this study. The cross sectional area sc, distance s (square root of sc) and the Flory radius (end to end dimension of polymer), Rf, for all the polymers was determined. The cross sectional area per PEO (Poly Ethylene Oxide) chain (nm2) was found to be increasing with the size of stabilizing chain. Triton X100 and Lugalvan BNO12 has the smaller stabilizing chains so occupy smaller cross sectional areas whereas PE/F108 and triton X405 have larger number of PEO units and occupy a larger cross sectional area. This shows that stabilizing chain regulates the adsorption amounts that are lower in case of lower number of EO units. The application of de Gennes theory to experimental results suggested brush configuration of adsorbed polymer molecules in case of PE/F 103, PE/F 108, Triton X100, Triton X405, NPE1800, Lugalvan BNO12, Hypermer B246 and OLOA 11000. Whereas, Hypermer LP1 is more likely found to be adsorbed on graphitic carbon black in loops and trains. (author)

  7. Radiological and archaeological investigation of a mummy from Roman Egypt curated in the National Museum of Lithuania.

    Science.gov (United States)

    Piombino-Mascali, Dario; Jankauskas, Rimantas; Snitkuvienė, Aldona; Rutkauskas, Tadas; Sutherland, M Linda

    2016-01-01

    Among the collections belonging to the National Museum of Lithuania at Vilnius, resides an ancient Egyptian coffin containing a mummified human body. The coffin and its occupant are believed to have belonged to the King of Poland and to have been located in his palace at Warsaw. At the turn of the last century, Egyptologists dated the coffin to the end of the 21st dynasty (1070 BC-945 BC), and described the item as coming from Thebes, belonging to Hori, priest of Amun-Ra. However, no investigation was ever carried out on the human body associated with the coffin. Within the framework of the Lithuanian Mummy Project, the preserved human remains underwent computed tomographic investigation in order to reconstruct the biological profile of the subject and to determine the embalming method employed. This led to the identification of a young adult male. Additionally, the mummy shroud was stylistically assessed in order to determine the mummy's chronology in Egyptian history. Interestingly, the body could be ascribed to the Roman period of Egypt (30 BC-395 AD) due to analogies with the burial shrouds of the Soter group. This indicates a reuse of the coffin at some point in history.

  8. Investigating the time-dependent zeta potential of wood surfaces.

    Science.gov (United States)

    Muff, Livius F; Luxbacher, Thomas; Burgert, Ingo; Michen, Benjamin

    2018-05-15

    This work reports on streaming potential measurements through natural capillaries in wood and investigates the cause of a time-dependent zeta potential measured during the equilibration of wood cell-walls with an electrolyte solution. For the biomaterial, this equilibration phase takes several hours, which is much longer than for many other materials that have been characterized by electrokinetic measurements. During this equilibration phase the zeta potential magnitude is decaying due to two parallel mechanisms: (i) the swelling of the cell-wall which causes a dimensional change reducing the charge density at the capillary interface; (ii) the transport of ions from the electrolyte solution into the permeable cell-wall which alters the electrical potential at the interface by internal charge compensation. The obtained results demonstrate the importance of equilibration kinetics for an accurate determination of the zeta potential, especially for materials that interact strongly with the measurement electrolyte. Moreover, the change in zeta potential with time can be correlated with the bulk swelling of wood if the effect of electrolyte ion diffusion is excluded. This study shows the potential of streaming potential measurements of wood, and possibly of other hygroscopic and nanoporous materials, to reveal kinetic information about their interaction with liquids, such as swelling and ion uptake. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Investigation of the sensitivity and specificity of radiological signs for diagnosis of periapical infection of equine cheek teeth.

    Science.gov (United States)

    Townsend, N B; Hawkes, C S; Rex, R; Boden, L A; Barakzai, S Z

    2011-03-01

    Radiography is commonly used for the diagnosis of equine cheek teeth (CT) infection but, to our knowledge, no study to date has evaluated the relative values of individual specific radiographic signs when making a diagnosis. To investigate the sensitivity and specificity of individual radiographic signs identified from the literature for the diagnosis of CT apical infection using a retrospective case-control study. Cropped radiographs taken using computed radiography of 41 apically infected CT and 41 control CT were independently blindly evaluated by 3 clinicians for the presence of 12 predetermined radiographic signs associated with CT apical infection. A final diagnosis of either noninfected or infected was made. Sensitivity and specificity were calculated for the presence or absence of each radiographic sign for each clinician. Uni- and multivariable conditional logistic regression were used to determine strength of association of the 12 radiographic signs with apical infection. Median sensitivity and specificity for the diagnosis of CT apical infection were 76 and 90%, respectively. Periapical sclerosis, clubbing of one or 2 roots, degree of clubbing and periapical halo formation had the highest sensitivities (73-90%), with moderate specificity (61-63%). Multivariable conditional logistic regression revealed that severity of periapical sclerosis and extensive periapical halo were strongly associated with CT apical infection. The presence of periapical sclerosis and formation of a periapical halo were strongly associated with CT apical infection. Computed radiography appears to have a higher sensitivity but similar specificity to previously published results using film radiography to detect CT apical infection. These findings may aid practitioners when interpreting radiographs of equine CT as to the relative significance of their findings. © 2010 EVJ Ltd.

  10. Estimation of the radiological consequences of dumping into the athmosphere and upon the surface waters caused by non-nuclear industrial processes in the Netherlands

    International Nuclear Information System (INIS)

    Punte, A.; Meijer, R.J. de; Put, L.W.

    1988-01-01

    The objective of this report is to make an estimation of the radiologic burden of the Dutch people caused by losses into the atmosphere and upon the surface waters by the non-nuclear industry in the Netherlands. All minerals and raw materials contain small quantities of radioactive materials. However, the concentrations in most minerals are small, the total amount of radioactivity can be considerable by using large amount of radioactivity can be considerable by using large amounts of minerals. As result from losses, storage and/or reuse of thhe rest materials liberated in these processes, a large part of the people may be exposed to an extra amount of ionizing radiation. In this report the risks and risk classes are formulated upon which the industrial brances may be subdivided. Therefore an estimation is made of the radionuclide-transport of the raw materials in various industrial branches. Next is is indicated how the amount of the losses from the radionuclide-transport can be estimated and how the limits of the risk classes can be translated into limits in the radionuclide-transport. Finally the risks for members of the critical groups and the general individual risks as result from the estimated losses and the from this resulting doses for distinguished industry branches. (author). 155 refs.; 6 figs.; 32 tabs

  11. A kit for the investigation of live Escherichia coli cell adhesion to glycosylated surfaces

    DEFF Research Database (Denmark)

    Hartmann, M.; Horst, A. K.; Klemm, Per

    2010-01-01

    A combination of microtiter plate functionalization techniques and two facile bacterial adhesion inhibition assays form a flexible toolbox for the investigation of bacterial adhesion mechanisms on glycosylated surfaces.......A combination of microtiter plate functionalization techniques and two facile bacterial adhesion inhibition assays form a flexible toolbox for the investigation of bacterial adhesion mechanisms on glycosylated surfaces....

  12. Cursory radiological assessment: Battelle Columbus Laboratory Decommissioning and Decontamination Project

    International Nuclear Information System (INIS)

    Smith, W.H.; Munyon, W.J.; Mosho, G.D.; Robinet, M.J.; Wynveen, R.A.

    1988-10-01

    This document reports on the results obtained from a cursory radiological assessment of various properties at the Battelle Columbus Laboratory, Columbia, Ohio. The cursory radiological assessment is part of a preliminary investigation for the Battelle Columbus Laboratory Decommissioning and Decontamination Project. The radiological assessment of Battelle Columbus Laboratory's two sites included conducting interior and exterior building surveys and collecting and analyzing air, sewer system, and soil samples. Direct radiological surveys were made of floor, wall, and overhead areas. Smear surveys were made on various interior building surfaces as well as the exterior building vents. Air samples were collected in select areas to determine concentrations of Rn-222, Rn-220, and Rn-219 daughters, in addition to any long-lived radioactive particulates. Radon-222 concentrations were continuously monitored over a 24-hr period at several building locations using a radon gas monitoring system. The sanitary sewer systems at King Avenue, West Jefferson-North, and West Jefferson-South were each sampled at select locations. All samples were submitted to the Argonne Analytical Chemistry Laboratory for various radiological and chemical analyses. Environmental soil corings were taken at both the King Avenue and West Jefferson sites to investigate the potential for soil contamination within the first 12-inches below grade. Further subsurface investigations at the West Jefferson-North and West Jefferson-South areas were conducted using soil boring techniques. 4 refs., 10 figs., 10 tabs

  13. Investigation of the Si(111) surface in uhv: oxidation and the effect of surface phosphorus

    International Nuclear Information System (INIS)

    Tom, H.W.K.; Zhu, X.D.; Shen, Y.R.; Somorjai, G.A.

    1984-06-01

    We have studied the initial stages of oxidation, the segregation of phosphorus, and the effect of phosphorus on oxidation of the Si(111) 7 x 7 surface using optical second-harmonic generation. We have also observed a (√3 x √3)R30 0 LEED pattern for P on Si

  14. Diagnostic radiology 1987

    International Nuclear Information System (INIS)

    Margulis, A.R.; Gooding, C.A.

    1987-01-01

    This is the latest version of the continuing education course on diagnostic radiology given yearly by the Department of Radiology at the University of California, San Francisco. The lectures are grouped into sections on gastrointestinal radiology, mammography, uroradiology, magnetic resonance, hepatobiliary radiology, pediatric radiology, ultrasound, interventional radiology, chest radiology, nuclear medicine, cardiovascular radiology, and skeletal radiology. Each section contains four to eight topics. Each of these consists of text that represents highlights in narrative form, selected illustrations, and a short bibliography. The presentation gives a general idea of what points were made in the lecture

  15. Evaluation of entrance surface-skin doses in animals submitted on exams of abdomen in veterinary radiology using Tl dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Veneziani, G. R.; Matsushima, L. C.; Campos, L. L. [Instituto de Pesquisas Energeticas e Nucleares, Gerencia de Metrologia das Radiacoes / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Filho, A. M., E-mail: venezianigr@gmail.com [Centro Universitario de Rio Petro - UNIRP, Rodovia Br 153 (Transbrasiliana), Km. 69 Sao Jose do Rio Preto, Sao Paulo (Brazil)

    2014-08-15

    The radiation protection has recently gained considerable attention in human medicine. In veterinary medicine has been some advances in radiodiagnostic and therapy for domestic animal like dogs and cats. It is notable the increase of the costs with domestic animals that are considered, by many people in the whole world, like members of family. However, an important parameter that must be taken into account is the increasing use of computed tomography and other equipment s that uses ionizing radiation, which may lead to comparatively high exposure of critical organs. The radiation dose is determined by the balance between therapeutic benefit and possible damage to surrounding normal tissues. This study aimed the evaluation of entrance surface-skin doses in dogs submitted to radiodiagnostic procedures of abdomen using the technique of thermoluminescent dosimetry (TLD). The radiation doses were measured using thermoluminescent dosimeters of LiF:Mg,Ti (TLD 100) and a dog phantom made with a plastic container, proportional to the dog size, fulfilled with water. (Author)

  16. Evaluation of entrance surface-skin doses in animals submitted on exams of abdomen in veterinary radiology using Tl dosimetry

    International Nuclear Information System (INIS)

    Veneziani, G. R.; Matsushima, L. C.; Campos, L. L.; Filho, A. M.

    2014-08-01

    The radiation protection has recently gained considerable attention in human medicine. In veterinary medicine has been some advances in radiodiagnostic and therapy for domestic animal like dogs and cats. It is notable the increase of the costs with domestic animals that are considered, by many people in the whole world, like members of family. However, an important parameter that must be taken into account is the increasing use of computed tomography and other equipment s that uses ionizing radiation, which may lead to comparatively high exposure of critical organs. The radiation dose is determined by the balance between therapeutic benefit and possible damage to surrounding normal tissues. This study aimed the evaluation of entrance surface-skin doses in dogs submitted to radiodiagnostic procedures of abdomen using the technique of thermoluminescent dosimetry (TLD). The radiation doses were measured using thermoluminescent dosimeters of LiF:Mg,Ti (TLD 100) and a dog phantom made with a plastic container, proportional to the dog size, fulfilled with water. (Author)

  17. Radiological characterization of waste drum contents and its implication for radiological protection measures

    International Nuclear Information System (INIS)

    Brandl, Alexander; Breitenecker, Katharina

    2008-01-01

    Full text: Nuclear Engineering Seibersdorf (NES) is responsible for collection, characterization, treatment, and interim storage of all radiological waste generated in Austria. Facilities for waste treatment at NES include an incinerator plant for burnable solid and liquid radiological wastes, a treatment facility for non-burnable liquid wastes, and a high-pressure compactor for non-burnable solid radiological wastes. All conditioned radiological waste transferred from the NES treatment facilities to interim storage is contained in 200-l waste drums as standard storage containers. Even though these standard waste drums cannot be distinguished by visual inspection, except for their unique labeling, their contents may differ significantly in physical parameters and activity distribution, depending on the mode of treatment necessary for the initial unconditioned waste packages. The range of differences in the drum contents spans from homogeneous activity distributions in a concrete matrix from ashes or sludges to discrete sources in discrete locations in a concrete slab to centered compacted pellets in a concrete casing. For reasons of efficiency, inspection and subsequent radiological protection measures are based on a screening system for external dose rate at the surface and at a distance of 1 m from the drum. However, the various activity distributions in the waste drums will give rise to differing dose rate distributions at these locations. This paper examines the dose rate distributions due to the various conditioning methods and radionuclides of interest, investigates the uncertainties for standard dose rate measurements from these distributions, and evaluates their impact on radiological protection measures taken by the storage facility staff. (author)

  18. Pediatric radiology

    International Nuclear Information System (INIS)

    Kirkpatrick, J.A. Jr.

    1985-01-01

    Computed tomography has made possible the excellent and basic work having to do with the characteristics of the trachea, its caliber, shape, and length in children. Another group of articles has to do with interventional pediatric radiology. This year there were a number of articles of which only a sample is included, dealing with therapeutic procedures involving drainage of abscesses, angioplasty, nephrostomy, therapeutic embolization, and the removal of esophageal foreign bodies. Obviously, there is no reason to think that techniques developed for the adult may not be applicable to the infant or child; also, there is no reason to believe that processes peculiar to the child should not be amenable to intervention, for instance, use of embolization of hepatic hemangioma and transluminal balloon valvuloplasty for pulmonary valvular stenosis. Among the reports and reviews, the author would add that sonography remains a basic imaging technique in pediatric radiology and each year its application broadens. For example, there is an excellent article having to do with sonography of the neonatal and infant hip and evaluation of the inferior vena cava and the gallbladder. Nuclear medicine continues to play a significant role in diagnosis, which is featured in two articles concerned with problems of the hip

  19. CORROSION AND SURFACE PROTECTION IN MACHINE MATERIALS FRICTION HAVE DIFFERENT SURFACE PAIRS EXPERIMENTAL INVESTIGATION OF FACTORS

    OpenAIRE

    Senai YALCINKAYA

    2017-01-01

    Friction force, normal force, linear change. The normal force varies with the loads on the friction object. In order to determine the friction force and the friction coefficient, the friction object and the friction speed are used. The experimental work was carried out in three stages. In the first stage, the effect of normal force on the friction force was studied. In the second step, the friction force of the friction surface area is influenced. The effect of the change of the s...

  20. Analysis of the Radiology Reports from Radiology Clinics

    International Nuclear Information System (INIS)

    Kim, Eun Jin; Kwack, Kyu Sung; Cho, Jae Hyun; Jang, Eun Ho

    2009-01-01

    The purpose of this study was to investigate the form and content of the radiology reports from radiology clinics in Korea. One hundred and sixty six radiology reports from 49 radiology clinics were collected, and these reports were referred to the academic tertiary medical center from March 2008 to February 2009. These included reports for CT (n = 18), MRI (n = 146) and examinations not specified (n = 2). Each report was evaluated for the presence of required contents (demographics, technical information, findings, conclusion, the name, license number and signature of the radiologist and the referring facility). These requirements were based on the guideline of the American College of Radiology and the previous research. The name of the patient, the gender, the body part, the type of examination, the time of examination and the conclusion, the name of the radiologist and the name of facility were well recorded in over 90% of the radiology reports. However, the identification number of the patient, the referring facility, the referring physician, the use of contrast material, the clinical information, the time of dictation, the signature of the radiologist and the license number of the radiologist were poorly recorded (less than 50%). The optimal format of a radiology report should be established for reliable and valid communication with clinicians

  1. Digital radiology

    International Nuclear Information System (INIS)

    Dallas, W.J.

    1990-01-01

    Radiology is vital to the life-saving efforts of surgeons and other physicians, but precious time can be lost generating the images and transferring them to and from the operating room. Furthermore, hospitals are straining under the task of storing and managing the deluge of diagnostic films produced every year. A 300-bed hospital generates about 1 gigabyte (8 x 10 9 bits) of picture information every day and is legally bound to hold it for three to seven years--30 years in the case of silicosis or black lung disease, illnesses that may have relevance to future lawsuits. Consequently, hospital warehouses are filling with x-ray film and written reports that are important for analysis of patient histories, for comparison between patients, and for analyzing the progress of disease. Yet only a fraction of the information's potential is being used because access is so complicated. What is more, films are easily lost, erasing valuable medical histories

  2. Investigation of reordered (001) Au surfaces by positive ion channeling spectroscopy, LEED and AES

    International Nuclear Information System (INIS)

    Appleton, B.R.; Noggle, T.S.; Miller, J.W.; Schow, O.E. III; Zehner, D.M.; Jenkins, L.H.; Barrett, J.H.

    1974-01-01

    As a consequence of the channeling phenomenon of positive ions in single crystals, the yield of ions Rutherford scattered from an oriented single crystal surface is dependent on the density of surface atoms exposed to the incident ion beam. Thus, the positive ion channeling spectroscopy (PICS) technique should provide a useful tool for studying reordered surfaces. This possibility was explored by examining the surfaces of epitaxially grown thin Au single crystals with the combined techniques of LEED-AES and PICS. The LEED and AES investigations showed that when the (001) surface was sputter cleaned in ultra-high vacuum, the normal (1 x 1) symmetry of the (001) surfaces reordered into a structure which gave a complex (5 x 20) LEED pattern. The yield and energy distributions of 1 MeV He ions scattered from the Au surfaces were used to determine the number of effective monolayers contributing to the normal and reordered surfaces. These combined measurements were used to characterize the nature of the reordered surface. The general applicability of the PICS technique for investigations of surface and near surface regions is discussed

  3. Investigation of inelastic scattering of ultracold neutrons with small energy transfer at solid state surfaces

    International Nuclear Information System (INIS)

    Lychagin, E.V.; Muzychka, A.Yu.; Nekhaev, G.V.; Strelkov, A.V.; Shvetsov, V.N.; Nesvizhevskij, V.V.; Tal'daev, R.R.

    2001-01-01

    Inelastic scattering of neutrons with small energy transfer of ∼10 -7 eV was investigated using gravitational UCN spectrometer. The probability of such a process at stainless steel and beryllium surfaces was measured. It was also estimated at copper surface. The measurement showed that the detected flux of neutrons scattered at beryllium and copper surfaces is ∼ 2 times higher at room temperature compared to that at the liquid nitrogen temperature. (author)

  4. Investigation of Liquid Metal Heat Exchanger Designs for Fission Surface Power

    Science.gov (United States)

    Dyson, Rodger W.; Penswick, Barry; Robbie, Malcolm; Geng, Steven M.

    2009-01-01

    Fission surface power is an option for future Moon and Mars surface missions. High power nuclear reactor heated Stirling convertors are an option to provide reliable power for long duration outpost operations. This report investigates various design approaches for the liquid metal to acceptor heat exchange and clarifies the details used in the analysis.

  5. What's So Bad about Being Wet All Over: Investigating Leaf Surface Wetness.

    Science.gov (United States)

    Brewer, Carol A.

    1996-01-01

    Presents investigations of leaf surface wetness that provide ideal opportunities for students to explore the relationships between leaf form and function, to study surface conditions of leaves and plant physiology, and to make predictions about plant adaptation in different environments. Describes simple procedures for exploring questions related…

  6. Surface tension of polymer melts - experimental investigations of its effect on polymer-polymer adhesion

    DEFF Research Database (Denmark)

    Jankova Atanasova, Katja; Islam, Mohammad Aminul; Hansen, Hans Nørgaard

    -polymer bond strength during two component polymer processing. Polymer materials PS, POM, ABS, PEl, PEEK and PC are chosen for the investigation. Pendant drop method showed that in case of PS and POM, the melt surface tension was decreased with increasing temperature. The substrate surface energies...

  7. Surface tension of polymer melts - experimental investigations of its effects on polymer-polymer adhesion

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul; Jankova Atanasova, Katja; Hansen, Hans Nørgaard

    -polymer bond strength during two component polymer processing. Polymer materials PS, POM, ABS, PEI, PEEK and PC are chosen for the investigation. Pendant drop method showed that in case of PS and POM, the melt surface tension was decreased with increasing temperature. The substrate surface energies...

  8. Radiologic protection in dental radiology

    International Nuclear Information System (INIS)

    Pacheco Jimenez, R.E.; Bermudez Jimenez, L.A.

    2000-01-01

    With this work and employing the radioprotection criterion, the authors pretend to minimize the risks associated to this practice; without losing the quality of the radiologic image. Odontology should perform the following criterions: 1. Justification: all operation of practice that implies exposition to radiations, should be reweighed, through an analysis of risks versus benefits, with the purpose to assure, that the total detriment will be small, compared to resultant benefit of this activity. 2. Optimization: all of the exposures should be maintained as low as reasonable possible, considering the social and economic factors. 3. Dose limit: any dose limit system should be considered as a top condition, nota as an admissible level. (S. Grainger)

  9. An experimental investigation of evaporating sessile droplet on super-hydrophobic surface

    International Nuclear Information System (INIS)

    Shin, Dong Hwan; Lee, Seong Hyuk; Yoo, Jung Yul

    2008-01-01

    The objective of this study is to investigate the evaporation process of a water droplet on hydrophobic and hydrophilic surfaces. Time-dependent contact angle, height, radius, surface area, and volume were measured for three different surfaces, such as glass, OctadecylTrichloroSilane(OTS), and AlkylKetene Dimmer(AKD) using a digital image analysis technique. For hydrophilic surfaces, the measured contact angle, liquid volume, and height are also compared with numerical estimation. It is found that for super-hydrophobic surfaces, the contact line becomes no longer pinned during evaporation, and three distinct stages for hydrophobic surface cannot be found. For the super-hydrophobic surface, it takes the longest time for evaporation because the droplet maintains spherical shape even near the end of evaporation process

  10. Paint for detection of radiological or chemical agents

    Science.gov (United States)

    Farmer, Joseph C [Tracy, CA; Brunk, James L [Martinez, CA; Day, Sumner Daniel [Danville, CA

    2010-08-24

    A paint that warns of radiological or chemical substances comprising a paint operatively connected to the surface, an indicator material carried by the paint that provides an indication of the radiological or chemical substances, and a thermo-activation material carried by the paint. In one embodiment, a method of warning of radiological or chemical substances comprising the steps of painting a surface with an indicator material, and monitoring the surface for indications of the radiological or chemical substances. In another embodiment, a paint is operatively connected to a vehicle and an indicator material is carried by the paint that provides an indication of the radiological or chemical substances.

  11. AN INVESTIGATION OF LOCAL EFFECTS ON SURFACE WARMING WITH GEOGRAPHICALLY WEIGHTED REGRESSION (GWR

    Directory of Open Access Journals (Sweden)

    Y. Xue

    2012-07-01

    Full Text Available Urban warming is sensitive to the nature (thermal properties, including albedo, water content, heat capacity and thermal conductivity and the placement (surface geometry or urban topography of urban surface. In the literature the spatial dependence and heterogeneity of urban thermal landscape is widely observed based on thermal infrared remote sensing within the urban environment. Urban surface warming is conceived as a big contribution to urban warming, the study of urban surface warming possesses significant meaning for probing into the problem of urban warming.The urban thermal landscape study takes advantage of the continuous surface derived from thermal infrared remote sensing at the landscape scale, the detailed variation of local surface temperature can be measured and analyzed through the systematic investigation. At the same time urban environmental factors can be quantified with remote sensing and GIS techniques. This enables a systematic investigation of urban thermal landscape with a link to be established between local environmental setting and surface temperature variation. The goal of this research is utilizing Geographically Weighted Regression (GWR to analyze the spatial relationship between urban form and surface temperature variation in order to clarify the local effects on surface warming, moreover to reveal the possible dynamics in the local influences of environmental indicators on the variation of local surface temperature across space and time. In this research, GWR analysis proved that the spatial variation in relationships between environmental setting and surface temperature was significant with Monte Carlo significance test and distinctive in day-night change. Comparatively, GWR facilitated the site specific investigation based on local statistical technique. The inference based on GWR model provided enriched information regarding the spatial variation of local environment effect on surface temperature variation which

  12. Corrective Action Investigation Plan for Corrective Action Unit 576: Miscellaneous Radiological Sites and Debris Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Matthews, Patrick [Navarro, Las Vegas, NV (United States)

    2016-12-01

    Corrective Action Unit (CAU) 576 is located in Areas 2, 3, 5, 8, and 9 of the Nevada National Security Site, which is approximately 65 miles northwest of Las Vegas, Nevada. CAU 576 is a grouping of sites where there has been a suspected release of contamination associated with nuclear testing. This document describes the planned investigation of CAU 576, which comprises the following corrective action sites (CASs): 00-99-01, Potential Source Material; 02-99-12, U-2af (Kennebec) Surface Rad-Chem Piping; 03-99-20, Area 3 Subsurface Rad-Chem Piping; 05-19-04, Frenchman Flat Rad Waste Dump ; 09-99-08, U-9x (Allegheny) Subsurface Rad-Chem Piping; 09-99-09, U-9its u24 (Avens-Alkermes) Surface Contaminated Flex Line These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives (CAAs). Additional information will be obtained by conducting a corrective action investigation before evaluating CAAs and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable CAAs that will be presented in the Corrective Action Decision Document (CADD).

  13. INVESTIGATION OF SOLAR ABSORPTANCE OF BUILDING EXTERNAL SURFACES FROM HEAT FLUX POINT OF VIEW

    Directory of Open Access Journals (Sweden)

    Meral ÖZEL

    2006-02-01

    Full Text Available In this study, solar absorptance of external surfaces of buildings has been numerically investigated from the heat gain and losses point of view. For this purpose, external surface solar absorptance was icreased from 0 to 1with an ratio of 0.1 and, for the summer and winter conditions, heat fluxs was calculated by considering orientations of the wall and its roof for brick and concrete structure materials. Besides, external surface absorptance was assumed as 0.2, 0.5 and 0.9, respectively. Than, heat gain and losses were calculated to insulation thickness increasing on the outdoor surface of wall. Results obtained were presented as graphics

  14. Radiological Control Manual

    International Nuclear Information System (INIS)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records

  15. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  16. Safety aspects in radiology

    International Nuclear Information System (INIS)

    Silva, D.C. da.

    1991-05-01

    The development of a program for the evaluation of the physical installations and operational procedures in diagnostic radiology with respect to radiation-safety is described. In addition, a proposal for the quality analysis of X-ray equipment and film-processing is presented. The purpose is both to ensure quality and safety of the radiology service, as well as to aid in the initial and in-service training of the staff. Interviews with patients, staff practicing radiology at a wide range of levels and the controlling authorities were carried out in the State of Rio de Janeiro in order to investigate the existence and the effective use of personal radioprotection equipment as well as user's and staff's concern for radiation safety. Additionally physical measurements were carried out in University Hospitals in Rio de Janeiro to assess the quality of equipment in day-to-day use. It was found that in the locations which did not have routine maintenance the equipment was generally in a poor state which lead to a high incidence of repetition of examinations and the consequent financial loss. (author)

  17. Investigation of Polyaniline and a Functionalised Derivative as Antimicrobial Additives to Create Contamination Resistant Surfaces

    Directory of Open Access Journals (Sweden)

    Julia Robertson

    2018-03-01

    Full Text Available Antimicrobial surfaces can be applied to break transmission pathways in hospitals. Polyaniline (PANI and poly(3-aminobenzoic acid (P3ABA are novel antimicrobial agents with potential as non-leaching additives to provide contamination resistant surfaces. The activity of PANI and P3ABA were investigated in suspension and as part of absorbent and non-absorbent surfaces. The effect of inoculum size and the presence of organic matter on surface activity was determined. PANI and P3ABA both demonstrated bactericidal activity against Escherichia coli and Staphylococcus aureus in suspension and as part of an absorbent surface. Only P3ABA showed antimicrobial activity in non-absorbent films. The results that are presented in this work support the use of P3ABA to create contamination resistant surfaces.

  18. In Situ Investigation the Photolysis of the PAHs Adsorbed on Mangrove Leaf Surfaces by Synchronous Solid Surface Fluorimetry

    Science.gov (United States)

    Wang, Ping; Wu, Tun-Hua; Zhang, Yong

    2014-01-01

    An established synchronous solid surface fluorimetry (S-SSF) was utilized for in situ study the photolysis processes of anthracene (An) and pyrene (Py) adsorbed on the leaf surfaces of Kandelia obovata seedlings (Ko) and Aegiceras corniculata (L.) Blanco seedlings (Ac). Experimental results demonstrated that the photolysis of An and Py adsorbed on the leaf surfaces of two mangrove species under the laboratory conditions, followed first-order kinetics with their photolysis rates in the order of Ac>Ko. In addition, with the same amount of substances, the photolysis rate of An adsorbed on the same mangrove leaf surfaces was much faster than the adsorbed Py. In order to investigate further, the photolysis processes of An and Py in water were also studied for comparison. And the photolysis of An and Py in water also followed first-order kinetics. Moreover, for the same initial amount, the photolysis rate of the PAH in water was faster than that adsorbed on the leaf surfaces of two mangrove species. Therefore, photochemical behaviors of PAHs were dependent not only on their molecular structures but also the physical-chemical properties of the substrates on which they are adsorbed. PMID:24404158

  19. Recommended radiological controls for tritium operations

    International Nuclear Information System (INIS)

    Mansfield, G.

    1992-01-01

    This informal report presents recommendations for an adequate radiological protection program for tritium operations. Topics include hazards analysis, facility design, personnel protection equipment, training, operational procedures, radiation monitoring, to include surface and airborne tritium contamination, and program management

  20. Radiological analysis of solids around the old uranium mine of Rosglas (Morbihan). CRIIRAD N.08-119 note

    International Nuclear Information System (INIS)

    2008-01-01

    As uranium mines present significant radiological contaminations years after their exploitation, this document reports preliminary investigations performed around old uranium mines in Brittany. This preliminary work showed significant radiological anomalies, with gamma radiation fluxes between ten and twenty times higher than the natural level. Measurement procedures and results are presented. Sampling has been performed on surface soil, stones and waters. Sample processing is briefly described. Results are commented in terms of contamination by uranium 238 and 235

  1. Investigations of the Fundamental Surface Reactions Involved in the Sorption and Desorption of Radionuclides

    International Nuclear Information System (INIS)

    Czerwinski, Ken; Heske, Clemens; Moser, Duane; Misra, Mnoranjan; McMillion, Glen

    2011-01-01

    Models for describing solution- and surface-phase reactions have been used for 30 years, but only recently applicable to complex surfaces. Duff et al., using micro-XANES, found that Pu was concentrated on Mn-oxide and smectite phases of zeolitic tuff, providing an evaluation of contaminant speciation on surfaces for modeling. Experiments at Los Alamos demonstrated that actinides display varying surface residence time distributions, probably reflective of mineral surface heterogeneity. We propose to investigate the sorption/desorption behavior of radionuclides from mineral surfaces, as effected by microorganisms, employing isolates from Nevada Test Site deep alluvium as a model system. Characterizations will include surface area, particle size distribution, x-ray diffraction (XRD), microprobe analysis, extractions, and microbiology. Surface interactions will be assessed by electron spectroscopy (XPS), x-ray absorption fine structure spectroscopy (XAFS), X-ray emission spectroscopy, transmission electron microscopy (TEM) and Scanning electron microscopy (SEM). Desert Research Institute (DRI), University of Nevada, Reno (UNR), and University of Nevada, Las Vegas (UNLV) researchers will collaborate to enhance scientific infrastructure and the understanding of contaminant behavior on surfaces, with broader implications for the management of DOE sites.

  2. Investigations of the Fundamental Surface Reactions Involved in the Sorption and Desorption of Radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Czerwinski, Ken; Heske, Clemens; Moser, Duane; Misra, Mnoranjan; McMillion, Glen

    2011-04-20

    Models for describing solution- and surface-phase reactions have been used for 30 years, but only recently applicable to complex surfaces. Duff et al., using micro-XANES, found that Pu was concentrated on Mn-oxide and smectite phases of zeolitic tuff, providing an evaluation of contaminant speciation on surfaces for modeling. Experiments at Los Alamos demonstrated that actinides display varying surface residence time distributions, probably reflective of mineral surface heterogeneity. We propose to investigate the sorption/desorption behavior of radionuclides from mineral surfaces, as effected by microorganisms, employing isolates from Nevada Test Site deep alluvium as a model system. Characterizations will include surface area, particle size distribution, x-ray diffraction (XRD), microprobe analysis, extractions, and microbiology. Surface interactions will be assessed by electron spectroscopy (XPS), x-ray absorption fine structure spectroscopy (XAFS), X-ray emission spectroscopy, transmission electron microscopy (TEM) and Scanning electron microscopy (SEM). Desert Research Institute (DRI), University of Nevada, Reno (UNR), and University of Nevada, Las Vegas (UNLV) researchers will collaborate to enhance scientific infrastructure and the understanding of contaminant behavior on surfaces, with broader implications for the management of DOE sites.

  3. Comparative investigation of optical techniques for topography measurement of rough plastic surfaces

    DEFF Research Database (Denmark)

    Bariani, Paolo; Hansen, Hans Nørgaard; Arlø, Uffe Rolf

    2003-01-01

    An experimental assessment of three-dimensional surface topography characterisation methods for use with rough plastic parts has been carried out. Also, calibration methods and measuring procedures including optimal measuring conditions have been developed and applied. The study is based on rough...... polypropylene parts manufactured by injection moulding. The mould was equipped with inserts with EDM machined surfaces (Sa  3.5 µm) in order to represent a typical tool surface for injection moulding. A focus detection laser scanning profiler, a confocal scanning laser microscope, a white light interferometer...... and, in addition, a scanning electron microscope, have been used in the analysis of plastic surfaces. This investigation has shown that topography assessment of rough plastic surfaces is critical to both white light interference microscope and confocal microscope while the focus detection laser...

  4. Investigation of ozone zero phenomenon using new electrode and surface analysis technique

    Science.gov (United States)

    Taguchi, M.; Ochiai, Y.; Kawagoe, R.; Kato, Y.; Teranishi, K.; Suzuki, S.; Itoh, H.

    2011-07-01

    Results of our experimental investigation on the ozone zero phenomenon suggested us the importance of the electrode surface condition. This means that the main cause of the phenomenon, that is, temporal decrease of ozone concentration at the outlet of DBD type ozone generator and the recovery characteristics from the phenomenon are considered as the surface reaction process, which are influenced strongly by the surface condition. The surface condition is never constant during the ozone generation and varies gradually or remarkably with time depending on the experimental conditions. Therefore we have been continued to make clear the cause of the phenomenon, for example, the reproducibility of the phenomenon, using new electrodes and together with the surface analysis technique etc. In this paper, we describe on the above results and discussion.

  5. Structural investigation of the (010) surface of the Al13 Fe4 catalyst.

    Science.gov (United States)

    Ledieu, J; Gaudry, É; Loli, L N Serkovic; Villaseca, S Alarcón; de Weerd, M-C; Hahne, M; Gille, P; Grin, Y; Dubois, J-M; Fournée, V

    2013-02-15

    We have investigated the structure of the Al(13)Fe(4)(010) surface using both experimental and ab initio computational methods. The results indicate that the topmost surface layers correspond to incomplete puckered (P) planes present in the bulk crystal structure. The main building block of the corrugated termination consists of two adjacent pentagons of Al atoms, each centered by a protruding Fe atom. These motifs are interconnected via additional Al atoms referred to as "glue" atoms which partially desorb above 873 K. The surface structure of lower atomic density compared to the bulk P plane is explained by a strong Fe-Al-Fe covalent polar interaction that preserves intact clusters at the surface. The proposed surface model with identified Fe-containing atomic ensembles could explain the Al(13)Fe(4) catalytic properties recently reported in line with the site-isolation concept [M. Armbrüster et al., Nat. Mater. 11, 690 (2012)].

  6. Methyl Butanoate Adsorption on MoS2 Surface: A Density Functional Theory Investigation

    Directory of Open Access Journals (Sweden)

    Prabowo Wahyu Aji Eko

    2018-01-01

    Full Text Available Methyl butanoate is one of the compound which is obtained from triglyceride molecule. It has hydrocarbon components and hence may produce hydrocarbon through hydrodeoxygenation (HDO or decarbonylation (DCO processes. The first step to uncover the underlying mechanism of HDO or DCO is to find the active site of methyl butanoate adsorption over the catalyst. This study attempts to investigate the active site of methyl butanoate adsorption on MoS2 surface. Stable bonding configuration for methyl butanoate adsorption on MoS2 is investigated by using density functional theory (DFT. This investigation consists of geometry optimisation and adsorption energy calculations. The stable configuration of methyl butanoate adsorption on MoS2 surface is found to be on top of Mo atom in Mo-edge surface.

  7. Radiology of syndromes

    International Nuclear Information System (INIS)

    Taybi, H.

    1982-01-01

    In the course of 20 years, the author has investigated the radiological aspects of many different syndromes. 541 of them are listed in this book, together with their typical X-ray pictures. Congenital deformities, genetic diseases, and acquired diseases with typical combinations of sigs and symptoms are presented with information on how to identify them. Clinical manifestations are briefly characterized, and hereditary aspects are mentioned. Pathological characteristics and names of the syndromes are presented. A bibliography is given for every syndrome for those who intend to deepen their knowledge. (orig./MG) [de

  8. Microbiological investigations of oxygen plasma treated parylene C surfaces for metal implant coating.

    Science.gov (United States)

    Golda-Cepa, M; Brzychczy-Wloch, M; Engvall, K; Aminlashgari, N; Hakkarainen, M; Kotarba, A

    2015-01-01

    Parylene C surface was modified by the use of oxygen plasma treatment and characterized by microscopic and surface-sensitive techniques (E-SEM, AFM, XPS, LDI-TOF-MS, contact angle). The influence of the treatment on surface properties was investigated by calculations of surface free energy (Owens-Wendt method). Moreover, early adhesion (Culture Plate Method, Optical Microscopy Test) and biofilm formation ability (Cristal Violet Assay) on the parylene C surface was investigated. The bacteria strains which are common causative agents of medical device-associated infections (Staphylococcus aureus, Staphylococcus epidermidis and Pseudomonas aeruginosa--reference strains and clinical isolates) were used. It was concluded that chemical (oxygen insertion) and physical (nanotopography generation) changes, have a significant impact on the biocompatibility in terms of increased hydrophilicity (θ w of unmodified sample = 88° ± 2°, θ w of 60 min modified sample = 17.6° ± 0.8°) and surface free energy (SFE of unmodified sample = 42.4 mJ/m(2), and for 60 min modified sample = 70.1 mJ/m(2)). At the same time, no statistical effect on biofilm production and bacteria attachment to the modified surface of any of the tested strains was observed. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Educational treasures in Radiology: The Radiology Olympics - striving for gold in Radiology education

    OpenAIRE

    Talanow, Roland

    2010-01-01

    This article focuses on Radiology Olympics (www.RadiologyOlympics.com) - a collaboration with the international Radiology community for Radiology education, Radiolopolis (www.Radiolopolis.com). The Radiology Olympics honour the movers and shakers in Radiology education and offer an easy to use platform for educating medical professionals based on Radiology cases.

  10. Investigations of thin p-GaN light-emitting diodes with surface plasmon compatible metallization

    DEFF Research Database (Denmark)

    Fadil, Ahmed; Ou, Yiyu; Iida, Daisuke

    2016-01-01

    We investigate device performance of InGaN light-emitting diodes with a 30-nm p-GaN layer. The metallization used to separate the p-contact from plasmonic metals, reveals limitations on current spreading which reduces surface plasmonic enhancement.......We investigate device performance of InGaN light-emitting diodes with a 30-nm p-GaN layer. The metallization used to separate the p-contact from plasmonic metals, reveals limitations on current spreading which reduces surface plasmonic enhancement....

  11. Investigation the effects of metallic substrate surfaces due to ion-plasma treatment

    International Nuclear Information System (INIS)

    Shulaev, V.M.; Taran, V.S.; Timoshenko, A.I.; Gasilin, V.V.

    2011-01-01

    It has been found correlation between modification effects and duration of ion-plasma cleaning the substrate surface with titanium ions. Experiments were carried out using serial vacuum-arc equipment ''Bulat-6'' at the stationary mode in non-filtered titanium plasma, which contained considerable quantity of evaporated material droplets. The polished cylinder substrates (diameter and height 9,14,20 mm) have been treated. The substrates were manufactured of stainless steel 12X18H10T and non-oxygen copper M00b. The substrates surface roughness after ion-plasma treatment has been investigated with electron microscope JEOL JSM-840 and optic interference non-contact profilograph- profilometer ''Micron-alpha''. According obtained results the surface of copper and stainless steel substrates has been treated to intensive modification, i.e. substrate surface after treatment significantly differs from initial one. During final ion-plasma treatment a number of effects occur: purification from surface oxides is accompanied with metallic surface ''contamination'' by the cathode material macrodroplets, surface micromelting accompanied by roughness increase, the surface layer annealing with noticeable decrease of hardness.

  12. Experimental and numerical investigation of laser forming of cylindrical surfaces with arbitrary radius of curvature

    Directory of Open Access Journals (Sweden)

    Mehdi Safari

    2016-09-01

    Full Text Available In this work, laser forming of cylindrical surfaces with arbitrary radius of curvature is investigated experimentally and numerically. For laser forming of cylindrical surfaces with arbitrary radius of curvature, a new and comprehensive method is proposed in this paper. This method contains simple linear irradiating lines and using an analytical method, required process parameters for laser forming of a cylindrical surface with a specific radius of curvature is proposed. In this method, laser output power, laser scanning speed and laser beam diameter are selected based on laser machine and process limitations. As in the laser forming of a cylindrical surface, parallel irradiating lines are needed; therefore key parameter for production of a cylindrical surface with a specific radius of curvature is the number of irradiating lines. Hence, in the proposed analytical method, the required number of irradiating lines for production of a cylindrical surface with a specific radius of curvature is suggested. Performance of the proposed method for production of cylindrical surface with a specific radius of curvature is verified with experimental tests. The results show that using proposed analytical method, cylindrical surfaces with any radius of curvature can be produced successfully.

  13. Experimental Investigation on Surface Quality Processed by Self-Excited Oscillation Pulsed Waterjet Peening.

    Science.gov (United States)

    Ding, Xiaolong; Kang, Yong; Li, Deng; Wang, Xiaochuan; Zeng, Dongping

    2017-08-25

    High-speed waterjet peening technology has attracted a lot of interest and is now being widely studied due to its great ability to strengthen metal surfaces. In order to further improve the mechanical properties of metals, self-excited oscillation pulsed waterjets (SOPWs) were used for surface peening with an experimental investigation focused on the surface topography and properties. By impinging the aluminum alloy (5052) specimens with SOPWs issuing from an organ-pipe oscillation nozzle, the hardness and roughness at various inlet pressures and stand-off distances were measured and analyzed, as well as the residual stress. Under the condition of optimum stand-off distances, the microscopic appearances of peened specimens obtained by SEM were displayed and analyzed. Results show that self-excited oscillation pulsed waterjet peening (SOPWP) is capable of improving the surface quality. More specifically, compared with an untreated surface, the hardness and residual stress of the peened surfaces were increased by 61.69% and 148%, respectively. There exists an optimal stand-off distance and operating pressure for creating the highest surface quality. SOPWP can produce almost the same enhancement effect as shot peening and lead to a lower surface roughness. Although such an approach is empirical and qualitative in nature, this procedure also generated information of value in guiding future theoretical and experimental work on the application of SOPWP in the industry practice.

  14. RCRA Facility Investigation report for Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1991-09-01

    This report presents data and information related to remedial investigation studies for Oak Ridge National Laboratory (ORNL). Information is included on a soil gas survey, surface radiological investigations of waste areas, and well installation for ground water monitoring

  15. NMR investigations of surfaces and interfaces using spin-polarized xenon

    Energy Technology Data Exchange (ETDEWEB)

    Gaede, Holly Caroline [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry

    1995-07-01

    129Xe NMR is potentially useful for the investigation of material surfaces, but has been limited to high surface area samples in which sufficient xenon can be loaded to achieve acceptable signal to noise ratios. In Chapter 2 conventional 129Xe NMR is used to study a high surface area polymer, a catalyst, and a confined liquid crystal to determine the topology of these systems. Further information about the spatial proximity of different sites of the catalyst and liquid crystal systems is determined through two dimensional exchange NMR in Chapter 3. Lower surface area systems may be investigated with spin-polarized xenon, which may be achieved through optical pumping and spin exchange. Optically polarized xenon can be up to 105times more sensitive than thermally polarized xenon. In Chapter 4 highly polarized xenon is used to examine the surface of poly(acrylonitrile) and the formation of xenon clathrate hydrates. An attractive use of polarized xenon is as a magnetization source in cross polarization experiments. Cross polarization from adsorbed polarized xenon may allow detection of surface nuclei with drastic enhancements. A non-selective low field thermal mixing technique is used to enhance the 13C signal of CO2 of xenon occluded in solid CO2 by a factor of 200. High-field cross polarization from xenon to proton on the surface of high surface area polymers has enabled signal enhancements of ~1,000. These studies, together with investigations of the efficiency of the cross polarization process from polarized xenon, are discussed in Chapter 5. Another use of polarized xenon is as an imaging contrast agent in systems that are not compatible with traditional contrast agents. The resolution attainable with this method is determined through images of structured phantoms in Chapter 6.

  16. Paint for detection of corrosion and warning of chemical and radiological attack

    Science.gov (United States)

    Farmer, Joseph C [Tracy, CA

    2010-08-24

    A system for warning of corrosion, chemical, or radiological substances. The system comprises painting a surface with a paint or coating that includes an indicator material and monitoring the surface for indications of the corrosion, chemical, or radiological substances.

  17. Experimental investigation on carbon nano tubes coated brass rectangular extended surfaces

    International Nuclear Information System (INIS)

    Senthilkumar, Rajendran; Prabhu, Sethuramalingam; Cheralathan, Marimuthu

    2013-01-01

    Finned surface has been extensively used for free convection cooling of internal combustion engines and several electronic kits etc. Here rectangular brass fin was preferred for analysis. Thermocouples were attached all over the surface of the fin in equal distances. The measurement of surface temperature and calculated convective heat transfer rate were reported for several heat input values. The overall system performance can be improved by enhancing heat transfer rate of extended surfaces. Based on the above requirement, brass surface was coated by carbon nano tubes. The temperature and heat transfer characteristics were investigated using Taguchi method for experimental design. Finally the performances of coated and non-coated rectangular brass fins were compared. The average percentage of increase in heat transfer rate was proved around 12% for carbon nanocoated rectangular brass fins. - Graphical abstract: The designed Natural and Forced convection Heat Transfer Test Rig measures the enhanced rate of heat transfer for nano coated rectangular fins than in non-coated fins. Highlights: ► Rectangular brass fins were preferred for convective heat transfer process. ► The rectangular brass fins are coated with multi wall carbon nano tubes in EBPVD process with nanometer thickness. ► Temperature and heat transfer rate were investigated for nanocoated and non-coated fins by using Taguchi method. ► Multi wall carbon nanotubes act as a pin fin to enhance surface area for effective convective heat transfer rate.

  18. Interventional Radiology: Stroke

    Science.gov (United States)

    ... Government affairs Global outreach Publications Annual Report IR Quarterly Journal of Vascular and Interventional Radiology Newsletters Practice Resources Quality Improvement Clinical practice MACRA Matters Health Policy, Economics, Coding Toolkits Society of Interventional Radiology 3975 Fair ...

  19. Investigation of the properties of different surfaces used in evaporation systems

    International Nuclear Information System (INIS)

    Kirichenko, E O; Gatapova, E Ya

    2016-01-01

    This paper presents a study of the properties of surfaces with nanocoatings of two types:NOA 81 photoresist with silanizationand NOA 65 photoresist. These surfaces are resistant to thermal and mechanical loads. The structure of the surfaces was investigated by scanning electron microscopy. The contact angle hysteresis for these surfaces was determinedby the standard DSA-100 KRUSSprocedure, in which theadvancing and receding contact angles are measured, and also by a second method - measuring the contact angle under isothermal droplet evaporation. The contact angle hysteresis values measured by the two different methods are in satisfactory agreement. The contact angle hysteresis was about 20° for the NOA 81 substrateand about 50° for NOA 65. (paper)

  20. Investigation of surface porosity measurements and compaction pressure as means to ensure consistent contact angle determinations

    DEFF Research Database (Denmark)

    Holm, René; Borkenfelt, Simon; Allesø, Morten

    2016-01-01

    for a compound is determined by its contact angle to a liquid, which in the present study was measured using the sessile drop method applied to a disc compact of the compound. Precise determination of the contact angle is important should it be used to either rank compounds or selected excipients to e.......g. increase the wetting from a solid dosage form. Since surface roughness of the compact has been suggested to influence the measurement this study investigated if the surface quality, in terms of surface porosity, had an influence on the measured contact angle. A correlation to surface porosity was observed......, however for six out of seven compounds similar results were obtained by applying a standard pressure (866MPa) to the discs in their preparation. The data presented in the present work therefore suggest that a constant high pressure should be sufficient for most compounds when determining the contact angle...

  1. Theoretical investigation of van der Waals forces between solid surfaces at nanoscales

    NARCIS (Netherlands)

    Kudryavtsev, Y.V.; Gelinck, E.R.M.; Fischer, H.R.

    2009-01-01

    A theoretical investigation of van der Waals forces acting between two solid silicon surfaces at separations from zero to approximately 20 nm is presented. We focused our efforts on the analysis of different factors that can cause deviations from the classical pressure-distance dependence p ∼ 1/D3.

  2. Investigations of the surface conductivity of silicon dioxide and methods to reduce it

    NARCIS (Netherlands)

    Voorthuyzen, J.A.; Keskin, K.; Bergveld, Piet

    1987-01-01

    In this paper we describe our investigations of the electrical conductivity of the silicon dioxide-air interface. It appears that this conductivity is caused by the adsorption of water vapour on the oxide surface and strongly depends on the relative humidity of the surrounding air. Considering this

  3. Investigation of creep in (Al2 + ZrO2)-ceramics by ultrasonic surface waves

    International Nuclear Information System (INIS)

    Schneider, D.; Krell, A.; Weiss, T.; Reich, T.

    1992-01-01

    This paper reports on the creep damage in inhomogeneously deformed regions of ceramic bending specimens that has been examined by measuring the propagation velocity of ultrasonic surface waves. Using ultrasonic equipment with a non-contact generation of surface waves by laser impulses and applying the Fourier transformation techniques for analyzing the surface wave dispersion, the procedure finally results in the surface wave velocity depending on the frequency in a desired surface region of a specimen. The measurement of the surface wave dispersion enables the evaluation of a microstructural gradient produced by inhomogeneously distributed creep porosity perpendicular to that surface. The porosity is then estimated using relationships between elastic parameters and porosity within the framework of a theory of elasticity inheterogeneous materials. The ultrasonic method has been applied to investigate the creep behavior of (Al 2 O 3 + 11 vol.% ZrO 2 )-ceramics with two different glass contents of 1 and 4 vol.%. At equal deformation strain, creep porosity rises in the material with increasing content of amorphous phase

  4. Adsorbate induced surface alloy formation investigated by near ambient pressure X-ray photoelectron spectroscopy

    DEFF Research Database (Denmark)

    Nierhoff, Anders Ulrik Fregerslev; Conradsen, Christian Nagstrup; McCarthy, David Norman

    2014-01-01

    Formation of meta-stable surface-alloys can be used as a way to tune the binding strength of reaction intermediates and could therefore be used as improved catalyst materials for heterogeneous catalysis. Understanding the role of adsorbates on such alloy surfaces can provide new insights for engi...... and bulk Pt contributions. The study provides direct evidence on how it is possible to monitor the surface structure under near operation conditions. © 2014 Elsevier B.V. All rights reserved.......Formation of meta-stable surface-alloys can be used as a way to tune the binding strength of reaction intermediates and could therefore be used as improved catalyst materials for heterogeneous catalysis. Understanding the role of adsorbates on such alloy surfaces can provide new insights...... for engineering of more active or selective catalyst materials. Dynamical surface changes on alloy surfaces due to the adsorption of reactants in high gas pressures are challenging to investigate using standard characterization tools. Here we apply synchrotron illuminated near ambient pressure X-ray photoelectron...

  5. Radiological diagnostics in hyperparathyroidism

    International Nuclear Information System (INIS)

    Moedder, U.; Kuhn, F.P.; Gruetzner, G.

    1991-01-01

    The most important radiologically detectable effects of the primary and secondary hyperparathyroidism of the skeletal system and the periarticular soft tissue structures are presented. In the following sensitivity and specificity of radiological imaging - sonography, scintigraphy, computed tomography, magnetic resonance imaging, arteriography and selective venous sampling - in the preoperative diagnostic of the parathyroid adenomas are discussed. Therefore, radiological imaging can be omitted before primary surgery. It was only in secondary surgery that radiological process proved useful and a guide during surgical intervention. (orig.) [de

  6. Radiology systems architecture.

    Science.gov (United States)

    Deibel, S R; Greenes, R A

    1996-05-01

    This article focuses on the software requirements for enterprise integration in radiology. The needs of a future radiology systems architecture are examined, both at a concrete functional level and at an abstract system-properties level. A component-based approach to software development is described and is validated in the context of each of the abstract system requirements for future radiology computing environments.

  7. Experimental and numerical investigation of liquid-metal free-surface flows in spallation targets

    Energy Technology Data Exchange (ETDEWEB)

    Batta, A., E-mail: batta@kit.edu [Karlsruhe Institute of Technology, Germany Hermann-von-Helmholtz-PLATZ 1, 76344 Eggenstein-Leopoldshafen (Germany); Class, A.G.; Litfin, K.; Wetzel, Th. [Karlsruhe Institute of Technology, Germany Hermann-von-Helmholtz-PLATZ 1, 76344 Eggenstein-Leopoldshafen (Germany); Moreau, V.; Massidda, L. [CRS4 Centre for Advanced Studies, Research and Development in Sardinia, Polaris, Edificio 1, 09010 Pula, CA (Italy); Thomas, S.; Lakehal, D. [ASCOMP GmbH Zurich, Zurich (Switzerland); Angeli, D.; Losi, G. [DIEF – Department of Engineering “Enzo Ferrari”, University of Modena and Reggio Emilia, via Vignolese 905, 41125 Modena (Italy); Mooney, K.G. [University of Massachusetts Amherst, Department of Mechanical and Industrial Engineering, Amherst (United States); Van Tichelen, K. [SCK-CEN, Belgian Nuclear Research Centre, Boeretang 200, 2400 Mol (Belgium)

    2015-08-15

    Highlights: • Experimental study of free surface for lead bismuth eutectic target. • Numerical investigation of free surface of a liquid metal target. • Advanced free surface modelling. - Abstract: Accelerator Driven Systems (ADS) are extensively investigated for the transmutation of high-level nuclear waste within many worldwide research programs. The first advanced design of an ADS system is currently developed in SCK• CEN, Mol, Belgium: the Multi-purpose hYbrid Research Reactor for High-tech Applications (MYRRHA). Many European research programs support the design of MYRRHA. In the framework of the Euratom project ‘Thermal Hydraulics of Innovative nuclear Systems (THINS)’ a liquid-metal free-surface experiment is performed at the Karlsruhe Liquid Metal Laboratory (KALLA) of Karlsruhe Institute of Technology (KIT). The experiment investigates a full-scale model of the concentric free-surface spallation target of MYRRHA using Lead Bismuth Eutectic (LBE) as coolant. In parallel, numerical free surface models are developed and tested which are reviewed in the article. A volume-of-fluid method, a moving mesh model, a free surface model combining the Level-Set method with Large-Eddy Simulation model and a smoothed-particle hydrodynamics approach are investigated. Verification of the tested models is based on the experimental results obtained within the THINS project and on previous water experiments performed at the University Catholic de Louvain (UCL) within the Euratom project ‘EUROpean Research Programme for the TRANSmutation of High Level Nuclear Waste in Accelerator Driven System (EUROTRANS)’. The design of the target enables a high fluid velocity and a stable surface at the beam entry. The purpose of this paper is to present an overview of both experimental and numerical results obtained for free surface target characterization. Without entering in technical details, the status, the major achievements and lessons for the future with respect to

  8. Radiological manifestations of intestinal tuberculosis

    International Nuclear Information System (INIS)

    Im, Jae Hoon

    1974-01-01

    Radiological findings of 87 cases of intestinal tuberculosis are analyzed and presented. The diagnosis was based on histopathology in 29 cases, and on clinical ground and radiological findings in 58 cases. The radio of male and female patients was 4:6, and peak incidence is between 10 and 30. Abdominal pain, diarrhea, weight loss, fever and general weakness are frequent symptoms, and tenderness of abdomen, ascites with abdominal distension, malnutrition and emaciation are frequent signs of the patients. Laboratory investigation reveal anemia, raised ESR, hypoalbuminaemia and positive occult blood reaction in the stool in most of the patients. Chest film show activity pulmonary tuberculosis in only 1/3 patients. There is no pathognomonic radiological findings in intestinal tuberculosis and their manifestations are protean, and differentiation from other inflammatory diseases and malignant tumors in gastrointestinal tract is very difficult on radiological ground alone. However, in patients with complaining vague abdominal symptoms and signs, the radiological diagnosis is most certain means in the decision of existence of organic lesion and suggestion of tuberculosis in the gastrointestinal tract and its extent as yet. Multiplicity of the lesion, involvement of adjacent organ such as peritoneum or mesenteric lymph nodes, typical nodularity or irregularity of mesenteric border and existence of active pulmonary tuberculosis are the suggestive findings of intestinal tuberculosis. In the diagnosis of inflammatory disease or malignant tumor of gastrointestinal tract, the possibility of tuberculosis should be borne in mind, and vice versa

  9. The Investigations of Friction under Die Surface Vibration in Cold Forging Process

    DEFF Research Database (Denmark)

    Jinming, Sha

    of the application of ultrasonic vibration on drawing, rolling and other metal forming process show that the load and friction coefficient would be decreased with the presence of ultrasonic vibration. Investigations on forging processes and under low frequency, especially the quantitative analysis of friction......The objective of this thesis is to fundamentally study the influence of die surface vibration on friction under low frequency in metal forging processes. The research includes vibrating tool system design for metal forming, theoretical and experimental investigations, and finite element simulations...... on die surface vibration in forging process. After a general introduction to friction mechanisms and friction test techniques in metal forming, the application of ultrasonic vibration in metal forming, the influence of sliding velocity on friction is described. Some earlier investigations...

  10. Investigation of thermal effect on exterior wall surface of building material at urban city area

    Energy Technology Data Exchange (ETDEWEB)

    Md Din, Mohd Fadhil; Dzinun, Hazlini; Ponraj, M.; Chelliapan, Shreeshivadasan; Noor, Zainura Zainun [Institute of Environmental Water Resources and Management (IPASA), Faculty of Civil Engineering, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor (Malaysia); Remaz, Dilshah [Faculty of Built Environment, Universiti Teknologi Malaysia, 81310 UTM Skudai, Johor (Malaysia); Iwao, Kenzo [Nagoya Institute of Technology, Nagoya (Japan)

    2012-07-01

    This paper describes the investigation of heat impact on the vertical surfaces of buildings based on their thermal behavior. The study was performed based on four building materials that is commonly used in Malaysia; brick, concrete, granite and white concrete tiles. The thermal performances on the building materials were investigated using a surface temperature sensor, data logging system and infrared thermography. Results showed that the brick had the capability to absorb and store heat greater than other materials during the investigation period. The normalized heat (total heat/solar radiation) of the brick was 0.093 and produces high heat (51% compared to granite), confirming a substantial amount of heat being released into the atmosphere through radiation and convection. The most sensitive material that absorbs and stores heat was in the following order: brick > concrete > granite > white concrete tiles. It was concluded that the type of exterior wall material used in buildings had significant impact to the environment.

  11. Experimental Investigation of Surface Layer Properties of High Thermal Conductivity Tool Steel after Electrical Discharge Machining

    Directory of Open Access Journals (Sweden)

    Rafał Świercz

    2017-12-01

    Full Text Available New materials require the use of advanced technology in manufacturing complex shape parts. One of the modern materials widely used in the tool industry for injection molds or hot stamping dies is high conductivity tool steel (HTCS 150. Due to its hardness (55 HRC and thermal conductivity at 66 W/mK, this material is difficult to machine by conventional treatment and is being increasingly manufactured by nonconventional technology such as electrical discharge machining (EDM. In the EDM process, material is removed from the workpiece by a series of electrical discharges that cause changes to the surface layers properties. The final state of the surface layer directly influences the durability of the produced elements. This paper presents the influence of EDM process parameters: discharge current Ic and the pulse time ton on surface layer properties. The experimental investigation was carried out with an experimental methodology design. Surface layers properties including roughness 3D parameters, the thickness of the white layer, heat affected zone, tempered layer and occurring micro cracks were investigated and described. The influence of the response surface methodology (RSM of discharge current Ic and the pulse time ton on the thickness of the white layer and roughness parameters Sa, Sds and Ssc were described and established.

  12. Theoretical investigation of bulk ordering and surface segregation in Ag-Pd and other isoelectornic alloys

    Science.gov (United States)

    Ruban, A. V.; Simak, S. I.; Korzhavyi, P. A.; Johansson, B.

    2007-02-01

    Bulk ordering in Ag-Pd and other isoelectronic alloys is investigated theoretically by a number of first-principles techniques. The electronic structure and total energy have been calculated by the Green’s function Korringa-Kohn-Rostocker and full-potential plane wave methods. The effective cluster interactions of the Ising-type Hamiltonian have been obtained by the screened generalized perturbation method. They reveal a complex concentration-dependent ordering behavior in these alloys due to band filling and Fermi surface effects. In particular we show that long-period superstructures are gradually stabilized by a great number of relatively weak long-range effective pair- and three-site interactions, which can be seen as “collective” effect. A similar complex concentration dependence is also found for surfaces of Ag-Pd alloys. The surface composition of the (111) and (100) surface of Ag75Pd25 , Ag50Pd50 , and Ag33Pd67 alloys have been then investigated by the surface Green’s function technique and the screened generalized perturbation method for the effective interactions of the Ising-type Hamiltonian and the grand canonical Monte Carlo method for statistical thermodynamic simulations at finite temperatures. We compare our results with experimental data and other theoretical calculations.

  13. A combined QCM and XPS investigation of asphaltene adsorption on metal surfaces.

    Science.gov (United States)

    Rudrake, Amit; Karan, Kunal; Horton, J Hugh

    2009-04-01

    To investigate asphaltene-metal interactions, a combined quartz crystal microbalance (QCM) and X-ray photoelectron spectroscopy (XPS) study of asphaltene adsorption on a gold surface was conducted. Adsorption experiments were conducted at 25 degrees C with solutions of asphaltenes in toluene at concentrations ranging from 50 to 1500 ppm. QCM measurements yielded information on the kinetics of adsorption and further assessment of the data allowed the estimation of equilibrium adsorption levels. XPS analysis of adsorbed and bulk asphaltene demonstrated the presence of carboxylic, thiophenic, sulfide, pyridinic and pyrrolic type functional groups. The intensity of the main carbon (C-H) peak was related to surface coverage of adsorbed asphaltene as a function of asphaltene concentration by a simple mathematical model. The mass adsorption data from the QCM experiments also allowed estimation of the surface coverage, which was compared to those from XPS analyses. Surface coverage estimates as a function of asphaltene concentration could be described by a Langmuir (type-I) isotherm. The free energy of asphaltene adsorption was estimated to be -26.8+/-0.1 and -27.3+/-0.1 kJ/mol from QCM and XPS data, respectively assuming asphaltene molar mass of 750 g/gmol. QCM and XPS data was also analyzed to estimate adsorbed layer thickness after accounting for surface coverage. The thickness of the adsorbed asphaltene estimated from both XPS and QCM data analyses ranged from 6-8 nm over the entire range of adsorption concentrations investigated.

  14. Investigation of Aqueous Lubricants on Polymer Surfaces by Nanoindenter-based Scratch Tests

    Science.gov (United States)

    Krause, Wendy E.; Liang, Jing; Song, Junlong; Rojas, Orlando J.

    2010-03-01

    Nanoindenter-based scratch (nanoscratch) tests were successfully used to study lubrication at the microscale in the presence of a fluid film. The influence of aqueous lubricants on both hydrophobic (polypropylene and polyethylene) and hydrophilic (cellulose) surfaces was investigated. The lubricants consisted of aqueous solutions of amphiphilic block copolymers of ethylene oxide (EO) and propylene oxide (PO). The coefficients of friction were measured in the presence of lubricant solution on the solid surfaces. An improved lubricity (i.e., coefficient of friction decreased) was observed to occur as the adsorption excess increased.

  15. Surface roughening and rippling during plasma etching of silicon: Numerical investigations and a comparison with experiments

    OpenAIRE

    Tsuda, Hirotaka; Nakazaki, Nobuya; Takao, Yoshinori; Eriguchi, Koji; Ono, Kouichi

    2014-01-01

    Atomic- or nanometer-scale surface roughening and rippling during Si etching in high-density Cl2 and Cl2/O2 plasmas have been investigated by developing a three-dimensional atomic-scale cellular model (ASCeM-3D), which is a 3D Monte Carlo-based simulation model for plasma-surface interactions and the feature profile evolution during plasma etching. The model took into account the behavior of Cl+ ions, Cl and O neutrals, and etch products and byproducts of SiClx and SiClxOy in microstructures ...

  16. Experimental investigation on shrinkage and surface replication of injection moulded ceramic parts

    DEFF Research Database (Denmark)

    Islam, Aminul; Giannekas, Nikolaos; Marhöfer, David Maximilian

    2014-01-01

    Ceramic moulded parts are increasingly being used in advanced components and devices due to their unprecedented material and performance attributes. The surface finish, replication quality and material shrinkage are of immense importance for moulded ceramic parts intended for precision applications....... The current paper presents a thorough investigation on the process of ceramic moulding where it systematically characterizes the surface replication and shrinkage behaviours of precision moulded ceramic components. The test parts are moulded from Catamold TZP-A which is Y2O3-stabilised ZrO2 having widespread...... distribution for the moulded ceramic parts is presented....

  17. Direct investigation of (sub-) surface preparation artifacts in GaAs based materials by FIB sectioning

    Energy Technology Data Exchange (ETDEWEB)

    Belz, Jürgen; Beyer, Andreas; Torunski, Torsten; Stolz, Wolfgang; Volz, Kerstin

    2016-04-15

    The introduction of preparation artifacts is almost inevitable when producing samples for (scanning) transmission electron microscopy ((S)TEM). These artifacts can be divided in extrinsic artifacts like damage processes and intrinsic artifacts caused by the deviations from the volume strain state in thin elastically strained material systems. The reduction and estimation of those effects is of great importance for the quantitative analysis of (S)TEM images. Thus, optimized ion beam preparation conditions are investigated for high quality samples. Therefore, the surface topology is investigated directly with atomic force microscopy (AFM) on the actual TEM samples. Additionally, the sectioning of those samples by a focused ion beam (FIB) is used to investigate the damage depth profile directly in the TEM. The AFM measurements show good quantitative agreement of sample height modulation due to strain relaxation to finite elements simulations. Strong indications of (sub-) surface damage by ion beams are observed. Their influence on high angle annular dark field (HAADF) imaging is estimated with focus on thickness determination by absolute intensity methods. Data consolidation of AFM and TEM measurements reveals a 3.5 nm surface amorphization, negligible surface roughness on the scale of angstroms and a sub-surface damage profile in the range of up to 8.0 nm in crystalline gallium arsenide (GaAs) and GaAs-based ternary alloys. A correction scheme for thickness evaluation of absolute HAADF intensities is proposed and applied for GaAs based materials. - Highlights: • The damage by Ar-ion milling during TEM sample preparation is investigated directly. • After FIB sectioning damage and deep disorder of c-GaAs is seen in cross-section. • The influence of such disorder on conventional ADF measurements is estimated. • A correction for HAADF measurements is proposed with focus on thickness estimations.

  18. Investigation of Titan's surface and atmosphere photometric functions using the Cassini/VIMS instrument

    Science.gov (United States)

    Cornet, Thomas; Altobelli, Nicolas; Rodriguez, Sébastien; Maltagliati, Luca; Le Mouélic, Stéphane; Sotin, Christophe; Brown, Robert; Barnes, Jason; Buratti, Bonnie; Baines, Kevin; Clark, Roger; Nicholson, Phillip

    2015-04-01

    of I/F at 5 microns at very low phase angles, which is indicative of an opposition effect for the surface, and kinks in the I/F at low and high emergence/phase angles, increasing with decreasing wavelength (and thus with increasing atmospheric scattering). The latter dependency is present in both pure atmosphere and surface-atmosphere images, which clearly indicates that it is of atmospheric origin. We are currently investigating these dependencies with angles and try to determine best fit models that would describe the phase curves for the surface at 5 microns and for the atmosphere at lower wavelengths in this particular area.

  19. Medical Student Perceptions of Radiology Use in Anatomy Teaching

    Science.gov (United States)

    Murphy, Kevin P.; Crush, Lee; O'Malley, Eoin; Daly, Fergus E.; Twomey, Maria; O'Tuathaigh, Colm M. P.; Maher, Michael M.; Cryan, John F.; O'Connor, Owen J.

    2015-01-01

    The use of radiology in the teaching of anatomy to medical students is gaining in popularity; however, there is wide variation in how and when radiology is introduced into the curriculum. The authors sought to investigate students' perceptions regarding methods used to depict and teach anatomy and effects of integrated radiology instruction on…

  20. Investigation and Evaluation on Influence of Machining (CNC Conditions on Surface Quality of Paulownia Wood

    Directory of Open Access Journals (Sweden)

    Mohammad Aghajani

    2012-01-01

    Full Text Available The aim of this study was to investigate the effective factors on surface quality of paulownia wood during machining by advanced computer numerical controled (CNC machine. For this aim paulownia logs were provided and were converted to proper sizes (2.5 x 10 x 15 cm and then air dried. The Variable of this study were cutting speed (8.37 and 15.07 m/s, feeding rate (6 and 12 m/min, cutting depth (1and 5 mm, cutting method (down and up-milling and cutting pattern (tangential and radial. Roughness of cut specimens edge were evaluated by profilometer method according to ISO 13565 standard. For evaluation of surface quality, average roughness (Ra, maximum roughness (R max, valley roughness (Rv and peak roughness (Rp were used. Degrees of effectiveness of the parameters were evaluated by fractional factorial design as completely random design at confidence level of 95%. The result showed that cutting speed, cutting method and feed rate are influencive factors on surface quality of machined specimens and their effects were significant. With increasing cutting speed and decreasing feeding rate the roughness decreased and surface quality improved. In up-milling cutting method, degree of roughness was higher and consequently surface quality was inferior. It is to be noted that cutting method in comparison to other factors had the high influence on surface quality. The rest variables did now have independent influence on surface quality at 95% Confidence level. This study for achieving the optimum surface quality recommends that cutting speed of 15.07 m/s, feeding rate of 6 m/min, cutting method of down-milling and cutting depth of 1 mm for tangential cross section.

  1. Experimental investigation of moving surfaces for boundary layer and circulation control of airfoils and wings

    Science.gov (United States)

    Vets, Robert

    An experimental study was conducted to assess the application of a moving surface to affect boundary layers and circulation around airfoils for the purpose of altering and enhancing aerodynamic performance of finite wings at moderate Reynolds numbers. The moving surface was established by a wide, lightweight, nylon belt that enveloped a wing's symmetric airfoil profile articulated via a friction drive cylinder such that the direction of the upper surface was in the direction of the free stream. A water tunnel visualization study accompanied wind tunnel testing at the University of Washington, Kirsten Wind Tunnel of finite wings. An experimental study was conducted to assess the application of a moving surface to affect boundary layers and circulation around airfoils for the purpose of altering and enhancing aerodynamic performance of finite wings at moderate Reynolds numbers. The moving surface was established by a wide, lightweight, nylon belt that enveloped a wing's symmetric airfoil profile articulated via a friction drive cylinder such that the direction of the upper surface was in the direction of the free stream. A water tunnel visualization study accompanied wind tunnel testing at the University of Washington, Kirsten Wind Tunnel of finite wings. The defining non-dimensional parameter for the system is the ratio of the surface velocity to the free stream velocity, us/Uo. Results show a general increase in lift with increasing us/Uo. The endurance parameter served as an additional metric for the system's performance. Examining the results of the endurance parameter shows general increase in endurance and lift with the moving surface activated. Peak performance in terms of increased endurance along with increased lift occurs at or slightly above us/Uo = 1. Water tunnel visualization showed a marked difference in the downwash for velocity ratios greater than 1, supporting the measured data. Reynolds numbers for this investigation were 1.9E5 and 4.3E5, relevant

  2. Radiology and fine art.

    Science.gov (United States)

    Marinković, Slobodan; Stošić-Opinćal, Tatjana; Tomić, Oliver

    2012-07-01

    The radiologic aesthetics of some body parts and internal organs have inspired certain artists to create specific works of art. Our aim was to describe the link between radiology and fine art. We explored 13,625 artworks in the literature produced by 2049 artists and found several thousand photographs in an online image search. The examination revealed 271 radiologic artworks (1.99%) created by 59 artists (2.88%) who mainly applied radiography, sonography, CT, and MRI. Some authors produced radiologic artistic photographs, and others used radiologic images to create artful compositions, specific sculptures, or digital works. Many radiologic artworks have symbolic, metaphoric, or conceptual connotations. Radiology is clearly becoming an original and important field of modern art.

  3. Microscopic investigation of RF surfaces of 3 GHz niobium accelerator cavities following RF processing

    International Nuclear Information System (INIS)

    Graber, J.; Barnes, P.; Flynn, T.; Kirchgessner, J.; Knobloch, J.; Moffat, D.; Muller, H.; Padamsee, H.; Sears, J.

    1993-01-01

    RF processing of Superconducting accelerating cavities is achieved through a change in the electron field emission (FE) characteristics of the RF surface. The authors have examined the RF surfaces of several single-cell 3 GHz cavities, following RF processing, in a Scanning Electron Microscope (SEM). The RF processing sessions included both High Peak Power (P ≤ 50 kW) pulsed processing, and low power (≤ 20 W) continuous wave processing. The experimental apparatus also included a thermometer array on the cavity outer wall, allowing temperature maps to characterize the emission before and after RF processing gains. Multiple sites have been located in cavities which showed improvements in cavity behavior due to RF processing. Several SEM-located sites can be correlated with changes in thermometer signals, indicating a direct relationship between the surface site and emission reduction due to RF processing. Information gained from the SEM investigations and thermometry are used to enhance the theoretical model of RF processing

  4. Investigation of surface resistance of copper in classical and anomalous skin-effect region

    International Nuclear Information System (INIS)

    Kutovoj, V.A.; Egorov, A.M.

    2008-01-01

    The surface resistance of copper in classical and anomalous skin-effect region has been investigated, and the surface resistance improvement factor equal to the ratio of the surface resistance of copper at room temperature to that of helium temperature, depending on the electromagnetic field frequency, has been determined. The improvement factor has been shown to have inverse power law dependence on frequency. The frequencies at which the improvement factor of copper equals 10 have been determined. It has been found that the quality factor of a resonance high-frequency system made of copper, operating at temperature T ≥ 4.2 K can be increased 10 times or more as against a quality factor of a resonance high-frequency system operating at room temperature

  5. Numerical investigation of interactions of multiple spherical shock waves between themselves and with the underlying surface

    Science.gov (United States)

    Andrushchenko, V. A.; Murashkin, I. V.; Shevelev, Yu. D.

    2016-06-01

    Within the investigation of various aspects of asteroid and comet danger and, in particular, the explosion of several fragments of meteoroids in the atmosphere above the Earth surface, the toy problem about four point explosions in the case of their special arrangement above the underlying surface is numerically solved. Complex interactions of primary and secondary shock waves between themselves, with the hard surface, and with tangential discontinuities are examined. The structure of flow inside gas regions disturbed by the explosions—the occurrence of eddy structures in them and the influence of reflected shocks waves on them—are investigated. The tendency of the external wave fronts of each explosion to form a unified front and the tendency of their internal hot domains to merge into a joined configuration (where the second process proceeds a little later than the first one) is revealed. This unified front and joined configuration are qualitatively identical to the external internal structure for the solitary explosion. The specially arranged explosions are chosen because the effects of multiple diffraction, interference, and, the main thing, cumulation of spherical waves are manifested more clearly in this caseTwo variants with different altitude of the explosions above the surface are calculated.

  6. Investigation of series resistance and surface states in Au/n - GaP structures

    International Nuclear Information System (INIS)

    Kiymaz, A.; Onal, B.; Ozer, M.; Acar, S.

    2009-01-01

    The variation in series resistance and surface state density of Au/n - GaP Schottky diodes have been systematically investigated at room temperature by using capacitance-voltage C-V and conductance-voltage G/w-V measurements techniques. The C-V and G/w-V characteristics of these devices were investigated by considering series resistance effects in a wide frequency range. It is shown that the capacitance of the Au/n - GaP Schottky diode decreases with increasing frequency. It is assumed that the surface states were responsible for this behaviour. The distribution profile of Rs-V gives a peak in the depletion region at low frequencies and disappears with increasing frequencies

  7. Investigation of Selective Laser Melting Surface Alloyed Aluminium Metal Matrix Dispersive Reinforced Layers

    Science.gov (United States)

    Kamburov, V. V.; Dimitrova, R. B.; Kandeva, M. K.; Sofronov, Y. P.

    2018-01-01

    The aim of the paper is to investigate the improvement of mechanical properties and in particular wear resistance of laser surface alloyed dispersive reinforced thin layers produced by selective laser melting (SLM) technology. The wear resistance investigation of aluminium matrix composite layers in the conditions of dry friction surface with abrasive particles and nanoindentation tests were carried out. The process parameters (as scan speed) and their impact on the wear resistant layers have been evaluated. The alloyed layers containing metalized SiC particles were studied by Optical and Scanning Electron Microscopy (SEM) and Energy Dispersive X-ray microanalysis (EDX). The obtained experimental results of the laser alloyed thin layers show significant development of their wear resistance and nanohardness due to the incorporated reinforced phase of electroless nickel coated SiC particles.

  8. Investigation of antimicrobial activity and morphological properties of metal coated textile surfaces

    International Nuclear Information System (INIS)

    Aslan, Necdet; Sen, Tuba; Senturk, Kenan; Corukhlu, Turgay; Varturk, Ipek; Seker, S.; Shahidi, S.; Korachi, May; Dobrovolskiy, A.M.; Tsiolko, V.V.; Matsevich, S.V.; Keskin, S.S.

    2014-01-01

    The results of investigation antimicrobial and surface properties of the textiles metal coated by means of magnetron or the cleaning-deposition system, which is based on sequentially arranged DC anode layer accelerator and hollow cathode, are presented. The antimicrobial properties against bacteria E. coli and S. aureus of cotton and polyester/cotton textiles coated by Cu, Ti and Ag with the use of two different systems were examined and compared.

  9. Surface characterization of activated chalcopyrite particles via the FLSmidth ROL process. Part 1: Electron microscope investigations

    DEFF Research Database (Denmark)

    Karcz, Adam Paul; Damø, Anne Juul; Illerup, Jytte Boll

    of copper(II) to dope the semiconductor lattice and thereby "activate" the chalcopyrite, thereby reducing leach times below 2 hours (>98% recovery). Because the activation plays a major role in accelerating the leaching step, it is critical to understand the nature of this intermediate and its part...... in the ROL process. The current work presents results from electron microscope investigations of surface-activated particles....

  10. Investigation of using steel slag in hot mix asphalt for the surface course of flexible pavements

    Science.gov (United States)

    Nguyen, Hien Q.; Lu, Dai X.; Le, Son D.

    2018-04-01

    The rapid development of heavy industry in Vietnam leads to the establishments of steel industry. Steel slag, a by-product of steelwork industry, under Vietnamese’s law, was considered as a deleterious solid waste which needed to be processed and landfilled. However, this has changed recently, and steel slag is now seen as a normal or non-deleterious solid waste, and has been studied for reuse in the construction industry. In this study, steel slag was used, as a replacement for mineral aggregate, in hot mix asphalt. Two hot mix asphalt mixtures with an equivalent nominal aggregate size of 12.5 (C12.5) and 19 mm (C19) were produced using steel slag. In addition, one conventional hot mix asphalt mixture of C19 was produced using mineral aggregate for comparison purpose. Investigation in laboratory condition and trial sections was carried out on Marshall tests, surface roughness, skid resistance, and modulus of the pavement before and after applying a new surface course of hot mix asphalt. The study showed that all steel slag asphalt mixtures passed the Marshall stability and flow test requirements. The skid resistance of steel slag hot mix asphalt mixtures for the surface course satisfied the Vietnamese specification for asphalt. Moreover, the pavement sections with the surface course of steel slag hot mix asphalt showed a considerable higher modulus than that of the conventional one. Only the roughness of the surface course paved with C19 did not pass the requirement of the specification.

  11. Thermal hydraulic numerical investigation of the heavy liquid metal free surface of MYRRHA spallation target experimental

    International Nuclear Information System (INIS)

    Batta, A.; Class, A.

    2015-01-01

    The first advanced design of accelerator-driven systems (ADS) is currently being built in SCK-CEN (Mol, Belgium): MYRRHA (Multi-purpose hybrid research reactor for high-tech applications). The experiment investigates the free surface design of the MYRRHA target. The free surface lead-bismuth eutectic (LBE) liquid metal experiment is a full-scale model of the concentric MYRRHA target. The design of the target is combined with CFD simulations using a volume of fluid method accounting for mass transfer across the free surface. The model used has been validated with water experimental results. The design of the target enables a high fluid velocity and a stable surface at the beam entry. In the current work, we present numerical results of Star- CD simulations employing a high-resolution interface-capturing scheme in conjunction with the cavitation model for the nominal operation conditions. Thermal hydraulic of the target is considered for the nominal flow rate and nominal heat load. Results show that the target has a very stable free surface configuration for the considered flow rate and heat load

  12. Investigation of surface treatment of conductive wire in cylindrical atmospheric pressure plasmas

    International Nuclear Information System (INIS)

    Ye Rubin; Kagohashi, Tsutomu; Zheng Wei

    2009-01-01

    Polyethylene insulated electric wire was treated in He and Ar dielectric barrier discharge atmospheric pressure plasmas generated in a quartz tube wound with tubular electrodes. The wire was put penetrating through the high voltage and the grounded electrodes, improving the discharge and facilitating uniform surface treatment. In this work, the influences of conductivity of the wire on the effects of surface treatment and discharge behavior were investigated. Surface properties of the wire samples were analyzed by means of surface energy measurement and X-ray photoelectron spectroscopy. In order to reveal the mechanism for treating the conductive wire, I-V discharge waveforms were measured and time-resolved plasma images were taken. It was demonstrated that the conductive wire was involved in the discharge process, reducing the breakdown voltage significantly and enhancing the discharge. It shows that the discharge mode was strongly dependent on the conductivity of a wire. Intensive surface discharges developed along the conductive wire were found to be mainly responsible for noticeable improvement in the treatment effect.

  13. Methods for dynamic investigations of surface-attached in vitro bacterial and fungal biofilms

    DEFF Research Database (Denmark)

    Sternberg, Claus; Bjarnsholt, Thomas; Shirtliff, Mark

    2014-01-01

    Three dynamic models for the investigation of in vitro biofilm formation are described in this chapter. In the 6-well plate assay presented here, the placing of the plate on a rotating platform provides shear, thereby making the system dynamic with respect to the static microtiter assay.The second...... reported model, especially suitable for harvesting high amounts of cells for transcriptomic or proteomic investigations, is based on numerous glass beads placed in a flask incubated with shaking on a rotating platform, thus increasing the surface area for biofilm formation. Finally, the flow-cell system...

  14. Study on geological environment in the Tono area. An approach to surface-based investigation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-12-01

    Mizunami Underground Research (MIU) Project has aimed at preparation of basis of investigation, analysis and evaluation of geology of deep underground and basis of engineering technologies of ultra deep underground. This report stated an approach and information of surface-based investigation for ground water flow system and MIU Project by the following contents, 1) objects and preconditions, 2) information of geological environment for analysis of material transition and design of borehole, 3) modeling, 4) tests and investigations and 5) concept of investigation. The reference data consists of results of studies such as the geological construction model, topography, geologic map, structural map, linear structure and estimated fault, permeability, underground stream characteristics, the quality of underground water and rock mechanics. (S.Y.)

  15. Current status of the surface-based investigations in the MIU project

    International Nuclear Information System (INIS)

    Nakano, Katushi; Osawa, Hideaki

    2001-01-01

    Tono Geoscience Center (TGC) has been conducting a wide range of geoscientific research in order to build a firm scientific and technological basis for the research and development of geological disposal. One of the major components of the ongoing geoscientific research program is the Mizunami Underground Research Laboratory (MIU) project in the Tono region, central Japan. The R and D work of the MIU project has the following main goals: Develop comprehensive investigation techniques for the geological environment. Develop a range of engineering techniques for deep underground application. A wide range of geoscientific research and development activities of the MIU project is planned in three phases a 20 years period; Phase one: surface-based investigation. Phase two: construction. Phase three: operations. The MIU site has been investigated by geological, hydrogeological, hydrochemical and rock mechanical surveys on the surface. Based on this information, modeling and simulation works have been conducted in the different investigation stages. Technological knowledge and experience have been accumulated, which allow application of the methodologies and techniques to characterize the deep geological environment in crystalline rock. This report presents the results of the investigations from fiscal 1996 to 1999 in phase one. (author)

  16. Surface damage through grazing incidence ions investigated by scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Redinger, Alex

    2009-07-10

    Surface damage, caused by grazing incidence ions, is investigated with variable temperature scanning tunneling microscopy. The experiments are carried out on a Pt(111) crystal. The kinetic energy of noble gas ions is varied between 1-15 keV and the angle of incidence can be adjusted between {theta} = 78.5 and {theta} = 90 measured with respect to the surface normal. The damage patterns of single ion impacts, on flat terraces and at step edges of monoatomic height, are investigated at low surface temperatures. Ions hitting a flat terrace are usually specular reflected. The energy transfer from the ion to the crystal atoms is small and only little damage is produced. In contrast, at ascending step edges, which are illuminated by the ion beam, large angle scattering events occur. Sputtering, adatom and vacancy production is induced. However, a significant fraction of the ions, which hit step edges, enter the crystal and are guided in between two atomic layers parallel to the surface via small angle binary collisions. This steering process is denoted as subsurface channeling. The energy loss per length scale of the channeled particles is low, which results in long ion trajectories (up to 1000A). During the steering process, the ions produce surface damage. Depending on the ion species and the ion energy, adatom and vacancies or surface vacancy trenches of monoatomic width are observed. The surface damage can be used to track the path of the ion. This makes the whole trajectory of single ions with keV energy visible. The number of sputtered atoms per incident ion at ascending step edges, i.e. the step edge sputtering yield, is measured experimentally for different irradiation conditions. For {theta} = 86 , the sputtering yield is determined from the fluence dependent retraction of pre-existing illuminated step edges. An alternative method for the step edge sputtering yield determination, is the analysis of the concentration of ascending steps and of the removed amount

  17. Surface damage through grazing incidence ions investigated by scanning tunneling microscopy

    International Nuclear Information System (INIS)

    Redinger, Alex

    2009-01-01

    Surface damage, caused by grazing incidence ions, is investigated with variable temperature scanning tunneling microscopy. The experiments are carried out on a Pt(111) crystal. The kinetic energy of noble gas ions is varied between 1-15 keV and the angle of incidence can be adjusted between θ = 78.5 and θ = 90 measured with respect to the surface normal. The damage patterns of single ion impacts, on flat terraces and at step edges of monoatomic height, are investigated at low surface temperatures. Ions hitting a flat terrace are usually specular reflected. The energy transfer from the ion to the crystal atoms is small and only little damage is produced. In contrast, at ascending step edges, which are illuminated by the ion beam, large angle scattering events occur. Sputtering, adatom and vacancy production is induced. However, a significant fraction of the ions, which hit step edges, enter the crystal and are guided in between two atomic layers parallel to the surface via small angle binary collisions. This steering process is denoted as subsurface channeling. The energy loss per length scale of the channeled particles is low, which results in long ion trajectories (up to 1000A). During the steering process, the ions produce surface damage. Depending on the ion species and the ion energy, adatom and vacancies or surface vacancy trenches of monoatomic width are observed. The surface damage can be used to track the path of the ion. This makes the whole trajectory of single ions with keV energy visible. The number of sputtered atoms per incident ion at ascending step edges, i.e. the step edge sputtering yield, is measured experimentally for different irradiation conditions. For θ = 86 , the sputtering yield is determined from the fluence dependent retraction of pre-existing illuminated step edges. An alternative method for the step edge sputtering yield determination, is the analysis of the concentration of ascending steps and of the removed amount of material as a

  18. Comparative investigation of surface transfer doping of hydrogen terminated diamond by high electron affinity insulators

    Energy Technology Data Exchange (ETDEWEB)

    Verona, C.; Marinelli, Marco; Verona-Rinati, G. [Dip. di Ingegneria Industriale, Università di Roma “Tor Vergata,” Via del Politecnico 1, I-00133 Roma (Italy); Ciccognani, W.; Colangeli, S.; Limiti, E. [Dip. di Ingegneria Elettronica, Università di Roma “Tor Vergata,” Via del Politecnico 1, I-00133 Roma (Italy)

    2016-07-14

    We report on a comparative study of transfer doping of hydrogenated single crystal diamond surface by insulators featured by high electron affinity, such as Nb{sub 2}O{sub 5}, WO{sub 3}, V{sub 2}O{sub 5}, and MoO{sub 3}. The low electron affinity Al{sub 2}O{sub 3} was also investigated for comparison. Hole transport properties were evaluated in the passivated hydrogenated diamond films by Hall effect measurements, and were compared to un-passivated diamond films (air-induced doping). A drastic improvement was observed in passivated samples in terms of conductivity, stability with time, and resistance to high temperatures. The efficiency of the investigated insulators, as electron accepting materials in hydrogenated diamond surface, is consistent with their electronic structure. These surface acceptor materials generate a higher hole sheet concentration, up to 6.5 × 10{sup 13} cm{sup −2}, and a lower sheet resistance, down to 2.6 kΩ/sq, in comparison to the atmosphere-induced values of about 1 × 10{sup 13} cm{sup −2} and 10 kΩ/sq, respectively. On the other hand, hole mobilities were reduced by using high electron affinity insulator dopants. Hole mobility as a function of hole concentration in a hydrogenated diamond layer was also investigated, showing a well-defined monotonically decreasing trend.

  19. Surface analytical investigation of diamond coatings and nucleation processes by secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Steiner, R.

    1993-10-01

    Imaging SIMS for the investigation of substrate surfaces: the influence of the substrate surface on diamond nucleation is a major topic in the investigation of the chemical vapour deposition (CVD) of diamond. It is well known that the nucleation density can be enhanced by scratching the substrate surface with abrasive powders. Diamond can nucleate at scratches or at residues of the polishing material. In the present work the surface of refractory metals (Mo, Nb, Ta, W) polished with silicon carbide and diamond powder is studied by imaging (2- or 3-D) secondary ion mass spectrometry (SIMS). In first experiments the distribution of SiC and/or diamond residues after polishing was determined. The reaction of diamond with the substrate during heating to deposition temperatures was investigated. Investigation of WC/Co hardmetal substrates: it is well known that Co contained in the binder phase of the hard metal inhibits a strong adhesion between the diamond film and the substrate, which is need for an application as cutting tool. Several attempts to improve the adhesion have been reported up to now. In this work a pre-treatment procedure leading to the formation of Co compounds (borides and silicides) which are stable under diamond deposition conditions were investigated. Furthermore, the application of intermediate sputter layers consisting of chromium and titanium were studied. Investigation of P-doped diamond coatings: in the quaternary phase diagram C-P-B-N exist some phases with diamond structure and superhard phases (e.g BP, c-BN). Also a hypothetical superhard phase of the composition C 3 N 4 is predicted. A scientific objective is the synthesis of such phases by chemical vapour deposition. An increase of the phosphorus concentration effects a distinct change in the morphology of the deposited coatings. A major advantage of SIMS is that the concentration profiles can be measured through the whole film, due to the sputter removal of the sample, and the interface

  20. Numerical and Experimental Investigation for Heat Transfer Enhancement by Dimpled Surface Heat Exchanger in Thermoelectric Generator

    Science.gov (United States)

    Wang, Yiping; Li, Shuai; Yang, Xue; Deng, Yadong; Su, Chuqi

    2016-03-01

    For vehicle thermoelectric exhaust energy recovery, the temperature difference between the heat exchanger and the coolant has a strong influence on the electric power generation, and ribs are often employed to enhance the heat transfer of the heat exchanger. However, the introduction of ribs will result in a large unwanted pressure drop in the exhaust system which is unfavorable for the engine's efficiency. Therefore, how to enhance the heat transfer and control the pressure drop in the exhaust system is quite important for thermoelectric generators (TEG). In the current study, a symmetrical arrangement of dimpled surfaces staggered in the upper and lower surfaces of the heat exchanger was proposed to augment heat transfer rates with minimal pressure drop penalties. The turbulent flow characteristics and heat transfer performance of turbulent flow over the dimpled surface in a flat heat exchanger was investigated by numerical simulation and temperature measurements. The heat transfer capacity in terms of Nusselt number and the pressure loss in terms of Fanning friction factors of the exchanger were compared with those of the flat plate. The pressure loss and heat transfer characteristics of dimples with a depth-to-diameter ratio ( h/D) at 0.2 were investigated. Finally, a quite good heat transfer performance with minimal pressure drop heat exchanger in a vehicle TEG was obtained. And based on the area-averaged surface temperature of the heat exchanger and the Seeback effect, the power generation can be improved by about 15% at Re = 25,000 compared to a heat exchanger with a flat surface.

  1. Investigations of surface-tension effects due to small-scale complex boundaries

    Science.gov (United States)

    Feng, Jiansheng

    In this Ph.D. dissertation, we have investigated some important surface-tension phenomena including capillarity, wetting, and wicking. We mainly focus on the geometric aspects of these problems, and to learn about how structures affect properties. . In the first project (Chapter 2), we used numerical simulations and experiments to study the meniscus of a fluid confined in capillaries with complicated cross-sectional geometries. In the simulations, we computed the three-dimensional shapes of the menisci formed in polygonal and star-shaped capillaries with sharp or rounded corners. Height variations across the menisci were used to quantify the effect of surface tension. Analytical solutions were derived for all the cases where the cross-sectional geometry was a regular polygon or a regular star-shape. Power indices that characterize the effects of corner rounding were extracted from simulation results. These findings can serve as guide for fabrications of unconventional three-dimensional structures in Capillary Force Lithography experiments. Experimental demonstrations of the working principle was also performed. Although quantitative matching between simulation and experimental results was not achieved due to the limitation of material properties, clear qualitative trends were observed and interesting three-dimensional nano-structures were produced. A second project (Chapter 3) focused on developing techniques to produce three-dimensional hierarchically structured superhydrophobic surfaces with high aspect ratios. We experimented with two different high-throughput electron-beam-lithography processes featuring single and dual electron-beam exposures. After a surface modification procedure with a hydrophobic silane, the structured surfaces exhibited two distinct superhydrophobic behaviors---high and low adhesion. While both types of superhydrophobic surfaces exhibited very high (approximately 160° water advancing contact angles, the water receding contact angles on

  2. Investigation on the growth of DAST crystals of large surface area for THz applications

    International Nuclear Information System (INIS)

    Vijay, R. Jerald; Melikechi, N.; Thomas, Tina; Gunaseelan, R.; Arockiaraj, M. Antony; Sagayaraj, P.

    2012-01-01

    Graphical abstract: It is evident from the photographs that the crystal tend to grow as a needle (Fig. 1a) in the lower concentration region (2–3 g/200 mL); whereas, in the high concentration region (5 g/200 mL) though there is a marked enlargement in the size of the crystal, the morphology of the resulting DAST crystal is slightly irregular (Fig. 1d) in nature. Among the four concentrations employed, best result was obtained with the DAST–methanol solution of concentration 4 g/200 mL; which resulted in the DAST crystal of large surface area (270 mm 2 ) with high transparency and nearly square shape (Fig. 1c) in a growth period of 20–25 days. Highlights: ► DAST crystals of different sizes are obtained for different concentrations. ► The main focus is to grow DAST crystals with large surface area. ► Structural, optical, thermal and mechanical properties are investigated. - Abstract: The growth of high quality 4-N,N-dimethylamino-4-N-methyl-stilbazoliumtosylate (DAST) crystal with large surface area is reported by adopting the slope nucleation coupled slow evaporation method (SNM-SE). The structure and composition of the crystal are studied by single crystal X-ray diffraction and CHN analyses. The linear optical properties are investigated by UV–vis absorption. The melting point and thermal behavior of DAST are investigated using differential scanning calorimetric (DSC) and thermogravimetric analyses (TGA). The Vickers microhardness number (VHN) and work hardening coefficient of the grown crystal have been determined. The surface features of the DAST crystal are analyzed by scanning electron microscopy (SEM) and it confirmed the presence of narrow line defects (NLDs) in the sample.

  3. In situ investigation of titanium nitride surface dynamics: The role of surface and bulk mass transport processes

    Science.gov (United States)

    Bareno, Javier

    NaCl-structure TiN and related transition-metal (TM) nitrides are widely used as hard wear-resistant coatings on cutting tools, diffusion-barriers in microelectronic devices, corrosion-resistant layers on mechanical components, and abrasion-resistant thin films on optics and architectural glass. Since the elastic and physical properties of TiN are highly anisotropic, controlling the microstructural and surface morphological evolution of polycrystalline TM nitride films is important for all of the above applications. In this thesis, I used in-situ high-temperature low-energy electron microscopy (LEEM) to gain insight into film growth and microstructure development dynamics by studying mass-transport processes occurring during annealing of three dimensional (3D) structures on TiN surfaces. Additionally, in order to extend the current understanding of nanostructure development in binary nitride films to more complex ternary TM-nitride-based nanocomposites, I employed in-situ scanning tunneling microscopy (STM) and low-energy electron diffraction (LEED), as well as ab-initio modeling, to investigate the atomic structure of the SiNx/TiN heterointerfaces which control the properties of SiNx-TiN nanocomposites. The LEEM studies of mass transport on TiN(111) focus on two specific surface morphologies which are observed to be present during growth of TiN single-crystals. (1) I investigated the temperature-dependent coarsening/decay kinetics of three-dimensional TiN island mounds on large (>1000 A) atomically-flat terraces; showing that TiN(111) steps are highly permeable and exhibit strong repulsive temperature-dependent step-step interactions that vary from 0.03 eV-A at 1559 K to 0.76 eV-A at 1651 K. (2) I studied the nucleation and growth of spiral steps originating at surface-terminated screw dislocations; I developed a model of spiral growth relating the emission rate of point defects from the bulk to the temperature-dependent spiral rotation frequency o(T); and I

  4. Radiological protection report 2010

    International Nuclear Information System (INIS)

    2011-01-01

    This is the 7 th Annual Report of the Swiss Federal Nuclear Safety Inspectorate (ENSI) on radiological protection in Swiss nuclear facilities. Section A deals with doses for staff and individual jobs and Section B covers releases from nuclear facilities and the monitoring of environmental radioactivity in their immediate vicinity. The year under review was again marked by an event classified by ENSI as Level 2 on the INES Scale. During maintenance work in the fuel-assembly transfer system at the Leibstadt nuclear power station, a diver recovered a pipe-like object. The object, which was highly radioactive, was the end piece from a jacketed pipe previously removed from the in-core instrumentation. Subsequent investigations showed that the diver had been exposed to a hand dose of 7.5 Sv and a complete-body dose of 28 mSv, both in excess of the annual limits specified in the Swiss Radiological Protection Ordinance. As with the INES-2 event in 2009, this event showed that particular attention is required when working with high and variable radiation fields. In terms of radiological protection, a range of measures must be introduced as a matter of urgency, including for example, measures to ensure that acoustic alarms and warnings from electronic dosimeters are audible immediately even under difficult working conditions. In addition, there needs to be a systematic identification of radiation fields and this information must be made available to all concerned. Neither collective nor average individual doses have changed significantly in recent years. The average individual dose for personnel in nuclear facilities is now 0.7 mSv. This is significantly lower than both the maximum annual limit for persons exposed to radiation in the course of their work and the average annual rate of exposure to radon for the population in Switzerland as a whole (3.2 mSv). The maximum individual dose in the Leibstadt nuclear power plant was 28 mSv. The maximum dose rate at the Goesgen

  5. A novel high temperature scanning tunneling microscope for investigating semiconductor surfaces

    Science.gov (United States)

    Lamb, Mark Alan

    2001-11-01

    The issues concerning the description of structural and dynamic features at the nanometer scale has become an active field of research in surface science. The development of the scanning tunneling microscope (STM) has begun only recently to contribute substantially in this effort. For this dissertation project, the author has designed, constructed, and utilized a high temperature ultra high vacuum STM (HT-UHV-STM) for investigating semiconducting surfaces from room temperature to 790°C. In order to isolate the instrument from external noise, the author has developed and demonstrated a novel method of approaching decoupled passive magnetic levitation for vibration isolation. Using advanced magnet technology currently available, this isolation method could achieve resonance frequencies as low as 10-3 Hz for levitation pressures as high as several MPa in a single stage. The instrument has been used to study the clean Si(111) surface at high temperatures. The electromigration phenomenon has been utilized to modify the surface steps and produce metastable reconstruction zones of the "1 x 1" phase and 5 x 5 islands. The growth of the thermodynamically favored 7 x 7 reconstruction has been observed at high temperatures within these metastable phases. The production of nanostructures on the surface by the tip of the STM has been achieved and their thermal relaxation observed and analyzed. Several new observations include the appearance of periodic oscillations in the number of Si atoms constituting each of a pair of 5 x 5 magic islands, imaging of local melting and apparent sputtering of the surface by the tip, and the spontaneous formation of clusters by heat treatment.

  6. Insect Residue Contamination on Wing Leading Edge Surfaces: A Materials Investigation for Mitigation

    Science.gov (United States)

    Lorenzi, Tyler M.; Wohl, Christopher J.; Penner, Ronald K.; Smith, Joseph G.; Siochi, Emilie J.

    2011-01-01

    Flight tests have shown that residue from insect strikes on aircraft wing leading edge surfaces may induce localized transition of laminar to turbulent flow. The highest density of insect populations have been observed between ground level and 153 m during light winds (2.6 -- 5.1 m/s), high humidity, and temperatures from 21 -- 29 C. At a critical residue height, dependent on the airfoil and Reynolds number, boundary layer transition from laminar to turbulent results in increased drag and fuel consumption. Although this represents a minimal increase in fuel burn for conventional transport aircraft, future aircraft designs will rely on maintaining laminar flow across a larger portion of wing surfaces to reduce fuel burn during cruise. Thus, insect residue adhesion mitigation is most critical during takeoff and initial climb to maintain laminar flow in fuel-efficient aircraft configurations. Several exterior treatments investigated to mitigate insect residue buildup (e.g., paper, scrapers, surfactants, flexible surfaces) have shown potential; however, implementation has proven to be impractical. Current research is focused on evaluation of wing leading edge surface coatings that may reduce insect residue adhesion. Initial work under NASA's Environmentally Responsible Aviation Program focused on evaluation of several commercially available products (commercial off-the-shelf, COTS), polymers, and substituted alkoxy silanes that were applied to aluminum (Al) substrates. Surface energies of these coatings were determined from contact angle data and were correlated to residual insect excrescence on coated aluminum substrates using a custom-built "bug gun." Quantification of insect excrescence surface coverage was evaluated by a series of digital photographic image processing techniques.

  7. Combined DFT and XPS investigation of iodine anions adsorption on the sulfur terminated (001) chalcopyrite surface

    Energy Technology Data Exchange (ETDEWEB)

    Li, Kui, E-mail: likui9606@stu.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049 (China); Zhao, Yaolin, E-mail: zhaoyaolin@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049 (China); Zhang, Peng, E-mail: zp32@qq.com [Sino Shaanxi Nuclear Industry Group, Xi’an 710100 (China); He, Chaohui, E-mail: hechaohui@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049 (China); Deng, Jia, E-mail: djkokocase@stu.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xi’an 710049 (China); Ding, Shujiang, E-mail: dingsj@mail.xjtu.edu.cn [Department of Applied Chemistry, School of Science, Xi’an Jiaotong University, Xi’an 710049 (China); Shi, Weiqun, E-mail: shiwq@ihep.ac.cn [Key Laboratory of Nuclear Radiation and Nuclear Energy Technology and Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2016-12-30

    Highlights: • Metal surface sites of (001)-S surface of chalcopyrite show significant chemical affinity to iodide and iodate. • The energetically favorable active site is copper for iodide adsorption and iron for iodate adsorption, respectively. • Iodate undergoes a dissociative adsorption on the copper site of chalcopyrite surface. - Abstract: The adsorption of iodine anions (iodide and iodate) on the sulfur terminated (001) chalcopyrite surface has been systematically investigated combining first-principles calculations based on density functional theory (DFT) with X-ray photoelectron spectroscopy (XPS) measurements. Based on the total energy calculations and geometric optimization, the thermodynamically preferred site was copper atom for iodide adsorption and iron atom for iodate adsorption, respectively. In the case of Cu site mode, the iodate underwent a dissociative adsorption, where one I−O bond of iodate ion was broken and the dissociative oxygen atom adsorbed on the adjacent sulphur site. Projected density of states (PDOS) analysis further clarified the interaction mechanism between active sites of chalcopyrite surface and adsorbates. In addition, full-range XPS spectra qualitatively revealed the presence of iodine on chalcopyrite surface. High resolution XPS spectra of the I 3d peaks after adsorption verified the chemical environment of iodine. The binding energies of 618.8 eV and 623.5 eV for I 3d{sub 5/2} peaks unveiled that the adsorption of iodide and iodate ions on copper-iron sulfide minerals was the result of formation of low solubility metal iodides precipitate. Also two I 3d peaks with low intensity around 618 eV and 630 eV might be related to the inorganic reduction of iodate to iodide by reducing S{sup 2−} ion of chalcopyrite.

  8. Poul Erik Andersen's radiological work on Osteochondrodysplasias and interventional radiology

    DEFF Research Database (Denmark)

    Andersen, Poul Erik

    2011-01-01

    Hospital. His significant experience and extensive scientific work has led to many posts in the Danish Society of Interventional Radiology, the European Society of Radiology and the Cardiovascular and Interventional Radiological Society of Europe, where he is a fellow and has passed the European Board...... of Interventional Radiology - The European qualification in Interventional Radiology....

  9. Socioeconomic trends in radiology

    International Nuclear Information System (INIS)

    Barneveld Binkhuysen, F.H.

    1998-01-01

    For radiology the socioeconomic environment is a topic of increasing importance. In addition to the well-known important scientific developments in radiology such as interventional MRI, several other major trends can be recognized: (1) changes in the delivery of health care, in which all kinds of managed care are developing and will influence the practice of radiology, and (2) the process of computerization and digitization. The socioeconomic environment of radiology will be transformed by the developments in managed care, teleradiology and the integration of information systems. If radiologists want to manage future radiology departments they must have an understanding of the changes in the fields of economics and politics that are taking place and that will increasingly influence radiology. Some important and recognizable aspects of these changes will be described here. (orig.)

  10. Small bowel imaging - still a radiologic approach?

    Science.gov (United States)

    Markova, Ingrid; Kluchova, Katerina; Zboril, Radek; Mashlan, Miroslav; Herman, Miroslav

    2010-06-01

    surface of the small bowel especially in the event of obscure gastrointestinal bleeding and inflammatory diseases. In a comparison of endoscopic and radiologic approaches, radiologic techniques are less invasive for patients, they take less time to investigate and allow imaging the entire small bowel. Some do not involve radiation exposure (US, MR). Endoscopic methods are more expensive, more invasive, need longer examination time and technical special skills but without radiation exposure. The greatest advantage of some endoscopic methods is the possibility of mucosal biopsy in one step with diagnostic examination (EGD, push enteroscopy, intraoperative enteroscopy, ileocolonoscopy).

  11. Structural Investigations of Surfaces and Orientation-SpecificPhenomena in Nanocrystals and Their Assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Aruguete, Deborah Michiko [Univ. of California, Berkeley, CA (United States)

    2006-01-01

    Studies of colloidal nanocrystals and their assemblies are presented. Two of these studies concern the atomic-level structural characterization of the surfaces, interfaces, and interiors present in II-VI semiconductor nanorods. The third study investigates the crystallographic arrangement of cobalt nanocrystals in self-assembled aggregates. Crystallographically-aligned assemblies of colloidal CdSe nanorods are examined with linearly-polarized Se-EXAFS spectroscopy, which probes bonding along different directions in the nanorod. This orientation-specific probe is used, because it is expected that the presence of specific surfaces in a nanorod might cause bond relaxations specific to different crystallographic directions. Se-Se distances are found to be contracted along the long axis of the nanorod, while Cd-Se distances display no angular dependence, which is different from the bulk. Ab-initio density functional theory calculations upon CdSe nanowires indicate that relaxations on the rod surfaces cause these changes. ZnS/CdS-CdSe core-shell nanorods are studied with Se, Zn, Cd, and S X-ray absorption spectroscopy (XAS). It is hypothesized that there are two major factors influencing the core and shell structures of the nanorods: the large surface area-to-volume ratio, and epitaxial strain. The presence of the surface may induce bond rearrangements or relaxations to minimize surface energy; epitaxial strain might cause the core and shell lattices to contract or expand to minimize strain energy. A marked contraction of Zn-S bonds is observed in the core-shell nanorods, indicating that surface relaxations may dominate the structure of the nanorod (strain might otherwise drive the Zn-S lattice to accommodate the larger CdS or CdSe lattices via bond expansion). EXAFS and X-ray diffraction (XRD) indicate that Cd-Se bond relaxations might be anisotropic, an expected phenomenon for a rod-shaped nanocrystal. Ordered self-assembled aggregates of cobalt nanocrystals are

  12. Investigations on Surface Milling of Hardened AISI 4140 Steel with Pulse Jet MQL Applicator

    Science.gov (United States)

    Bashir, Mahmood Al; Mia, Mozammel; Dhar, Nikhil Ranjan

    2016-06-01

    In this article, an experimental investigation was performed in milling hardened AISI 4140 steel of hardness 40 HRC. The machining was performed in both dry and minimal quantity lubricant (MQL) conditions, as part of neat machining, to make a strong comparison of the undertaken machining environments. The MQL was impinged int the form of pulse jet, by using the specially developed pulse-jet-attachment, to ensure that the cutting fluid can be applied in different timed pulses and quantities at critical zones. The tool wear, cutting force and surface roughness were taken as the quality responses while cutting speed, table feed rate and flow rate of the pulse were considered as influential factors. The depth of cut was kept constant at 1.50 mm because of its less significant effects and the straight oil was adopted as cutting fluid in pulse-jet-MQL. The effects of different factors, on the quality responses, are analyzed using ANOVA. It is observed that MQL applicator system exhibits overall better performance when compared to dry milling by reducing surface roughness, cutting force and prolonging tool life but a flow rate of 150 ml/h has tremendous effects on the responses. This investigation and afterward results are expected to aid the industrial practitioner and researcher to adopt the pulse-MQL in high speed milling to prolong tool life, reduce tool wear, diminish cutting force generation and promote better surface finish.

  13. Theoretical investigation of lead vapor adsorption on kaolinite surfaces with DFT calculations.

    Science.gov (United States)

    Wang, Xinye; Huang, Yaji; Pan, Zhigang; Wang, Yongxing; Liu, Changqi

    2015-09-15

    Kaolinite can be used as the in-furnace sorbent/additive to adsorb lead (Pb) vapor at high temperature. In this paper, the adsorptions of Pb atom, PbO molecule and PbCl2 molecule on kaolinie surfaces were investigated by density functional theory (DFT) calculation. Si surface is inert to Pb vapor adsorption while Al surfaces with dehydroxylation are active for the unsaturated Al atoms and the O atoms losing H atoms. The adsorption energy of PbO is much higher than that of Pb atom and PbCl2. Considering the energy barriers, it is easy for PbO and PbCl2 to adsorb on Al surfaces but difficult to escape. The high energy barriers of de-HCl process cause the difficulties of PbCl2 to form PbO·Al2O3·2SiO2 with kaolinite. Considering the inertia of Si atoms and the activity of Al atoms after dehydroxylation, calcination, acid/alkali treatment and some other treatment aiming at amorphous silica producing and Al activity enhancement can be used as the modification measures to improve the performance of kaolinite as the in-furnace metal capture sorbent. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Investigation of reasons for small changes in energy of UCN due to their interaction with surface

    CERN Document Server

    Lychagin, E V; Nekhaev, G V; Strelkov, A V; Kartashov, D G; Nesvizhevsky, V V

    2002-01-01

    The nature of the phenomenon of small changes in energy of ultracold neutrons (UCN) has been investigated. This phenomenon occurs during collisions of UCN with a surface, which increase the UCN energy by approx 10 sup - sup 7 eV with a probability of 10 sup - sup 8 -10 sup - sup 5 per collision. Such neutrons are named VUCN. It was observed that the preliminary warming up of samples at 500-600 K leads to an increase of the small heating probability P sub V sub U sub C sub N by at least a factor of 100 for a surface of stainless steel and by a factor of 10 for a copper surface. Extremely intensive UCN small heating by a diamond nanopowder has been observed for the first time. The spectrum of these VUCN and the temperature dependence of their heating probability P sub V sub U sub C sub N are similar to those measured earlier for stainless steel, beryllium, and copper. It is not observed small UCN heating, nor nanoparticles on a monocrystalline sapphire surface. That leads to the conclusion that VUCN are produce...

  15. Experimental and theoretical investigations of mercury adsorption on hematite (1-102) surfaces

    Science.gov (United States)

    Jung, J.; Wilcox, J.; Jew, A. D.; Rupp, E. C.; Brown, G. E.

    2013-12-01

    Fly ash is a primary byproduct of the coal combustion process. The release of fly ash into the environment and its use in consumer products are public health concerns because of the presence of toxic trace metals and metalloids, such as mercury (Hg), selenium (Se), and arsenic (As), which may exist as components of fly ash, partition onto fly ash as it cools, or is lost to the environment through smoke stacks in a vapor phase. Therefore, it is important to understand the components of fly ash and their interaction with trace metals. In this study, calculations using density functional theory (DFT) were carried out in conjunction with experimental studies to investigate the interaction between Hg and hematite, an important mineral component of fly ash. Our experimental study, designed to simulate Hg sorption in a coal-fired power plant exhaust system, involved exposure of the fine fraction of bituminous coal fly ash (≤ 0.1 μm) to methane combustion flue gas, supplemented with SO2, NOx, HCl, and Hg in a packed-bed reactor. Sorption reaction products were characterized by synchrotron-based x-ray fluorescence mapping (s-XRF), x-ray diffraction (XRD), and extended x-ray absorption fine structure (EXAFS) spectroscopy. Preliminary s-XRF results showed that Hg in the sample is correlated with Fe, S, Cl, Br, and to a lesser extent with Se and As. From the XRD analysis, the dominant mineral phases detected were quartz, iron oxide (hematite), and various sulfate-bearing cements. Based on the experimental results, DFT studies were carried out to investigate the adsorption of Hg on hematite (α-Fe2O3) (1-102) surfaces. The two α-Fe2O3 (1-102) surfaces modeled consisted of two different surface terminations: (1) M2-clean, which corresponds to the oxygen terminated r-cut surface with the first layer of cations removed and no hydroxyl group and (2) M2-OH2-OH which has bihydroxylated top oxygen atoms and a second layer of hydroxylated oxygen atoms. These surface terminations

  16. Essentials of skeletal radiology

    Energy Technology Data Exchange (ETDEWEB)

    Yochum, T.R.; Rowe, L.J.

    1987-01-01

    This book discusses the following topics of skeletal radiology: Positioning of patients for diagnostic radiology and normal anatomy; congenital malformations of skeleton; measurements in radiology; spondylolisthesis; metabolic and endocrine diseases of bone and their diagnostic aspects; image processing of vertebrae, skeleton, bone fractures evaluations and epidemiological and social aspects of some bone diseases. Various modalities as CT scanning, NMR imaging, ultrasonography and biomedical radiography are briefly discussed in relation to bone pathology.

  17. Machine Learning and Radiology

    Science.gov (United States)

    Wang, Shijun; Summers, Ronald M.

    2012-01-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. PMID:22465077

  18. Radiological Emergency Response Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Quality Data Asset includes all current and historical emergency radiological response event and incident of national significance data and surveillance, monitoring,...

  19. Machine learning and radiology.

    Science.gov (United States)

    Wang, Shijun; Summers, Ronald M

    2012-07-01

    In this paper, we give a short introduction to machine learning and survey its applications in radiology. We focused on six categories of applications in radiology: medical image segmentation, registration, computer aided detection and diagnosis, brain function or activity analysis and neurological disease diagnosis from fMR images, content-based image retrieval systems for CT or MRI images, and text analysis of radiology reports using natural language processing (NLP) and natural language understanding (NLU). This survey shows that machine learning plays a key role in many radiology applications. Machine learning identifies complex patterns automatically and helps radiologists make intelligent decisions on radiology data such as conventional radiographs, CT, MRI, and PET images and radiology reports. In many applications, the performance of machine learning-based automatic detection and diagnosis systems has shown to be comparable to that of a well-trained and experienced radiologist. Technology development in machine learning and radiology will benefit from each other in the long run. Key contributions and common characteristics of machine learning techniques in radiology are discussed. We also discuss the problem of translating machine learning applications to the radiology clinical setting, including advantages and potential barriers. Copyright © 2012. Published by Elsevier B.V.

  20. Mobile computing for radiology.

    Science.gov (United States)

    Auffermann, William F; Chetlen, Alison L; Sharma, Arjun; Colucci, Andrew T; DeQuesada, Ivan M; Grajo, Joseph R; Kung, Justin W; Loehfelm, Thomas W; Sherry, Steven J

    2013-12-01

    The rapid advances in mobile computing technology have the potential to change the way radiology and medicine as a whole are practiced. Several mobile computing advances have not yet found application to the practice of radiology, while others have already been applied to radiology but are not in widespread clinical use. This review addresses several areas where radiology and medicine in general may benefit from adoption of the latest mobile computing technologies and speculates on potential future applications. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  1. A computational model to investigate the effect of pennation angle on surface electromyogram of Tibialis Anterior.

    Directory of Open Access Journals (Sweden)

    Diptasree Maitra Ghosh

    Full Text Available This study has described and experimentally validated the differential electrodes surface electromyography (sEMG model for tibialis anterior muscles during isometric contraction. This model has investigated the effect of pennation angle on the simulated sEMG signal. The results show that there is no significant effect of pennation angle in the range 0° to 20° to the single fibre action potential shape recorded on the skin surface. However, the changes with respect to pennation angle are observed in sEMG amplitude, frequency and fractal dimension. It is also observed that at different levels of muscle contractions there is similarity in the relationships with Root Mean Square, Median Frequency, and Fractal Dimension of the recorded and simulated sEMG signals.

  2. Chromate adsorption on selected soil minerals: Surface complexation modeling coupled with spectroscopic investigation

    Energy Technology Data Exchange (ETDEWEB)

    Veselská, Veronika, E-mail: veselskav@fzp.czu.cz [Department of Environmental Geosciences, Faculty of Environmental Sciences, Czech University of Life Sciences Prague, Kamýcka 129, CZ-16521, Prague (Czech Republic); Fajgar, Radek [Department of Analytical and Material Chemistry, Institute of Chemical Process Fundamentals of the CAS, v.v.i., Rozvojová 135/1, CZ-16502, Prague (Czech Republic); Číhalová, Sylva [Department of Environmental Geosciences, Faculty of Environmental Sciences, Czech University of Life Sciences Prague, Kamýcka 129, CZ-16521, Prague (Czech Republic); Bolanz, Ralph M. [Institute of Geosciences, Friedrich-Schiller-University Jena, Carl-Zeiss-Promenade 10, DE-07745, Jena (Germany); Göttlicher, Jörg; Steininger, Ralph [ANKA Synchrotron Radiation Facility, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, DE-76344, Eggenstein-Leopoldshafen (Germany); Siddique, Jamal A.; Komárek, Michael [Department of Environmental Geosciences, Faculty of Environmental Sciences, Czech University of Life Sciences Prague, Kamýcka 129, CZ-16521, Prague (Czech Republic)

    2016-11-15

    Highlights: • Study of Cr(VI) adsorption on soil minerals over a large range of conditions. • Combined surface complexation modeling and spectroscopic techniques. • Diffuse-layer and triple-layer models used to obtain fits to experimental data. • Speciation of Cr(VI) and Cr(III) was assessed. - Abstract: This study investigates the mechanisms of Cr(VI) adsorption on natural clay (illite and kaolinite) and synthetic (birnessite and ferrihydrite) minerals, including its speciation changes, and combining quantitative thermodynamically based mechanistic surface complexation models (SCMs) with spectroscopic measurements. Series of adsorption experiments have been performed at different pH values (3–10), ionic strengths (0.001–0.1 M KNO{sub 3}), sorbate concentrations (10{sup −4}, 10{sup −5}, and 10{sup −6} M Cr(VI)), and sorbate/sorbent ratios (50–500). Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and X-ray absorption spectroscopy were used to determine the surface complexes, including surface reactions. Adsorption of Cr(VI) is strongly ionic strength dependent. For ferrihydrite at pH <7, a simple diffuse-layer model provides a reasonable prediction of adsorption. For birnessite, bidentate inner-sphere complexes of chromate and dichromate resulted in a better diffuse-layer model fit. For kaolinite, outer-sphere complexation prevails mainly at lower Cr(VI) loadings. Dissolution of solid phases needs to be considered for better SCMs fits. The coupled SCM and spectroscopic approach is thus useful for investigating individual minerals responsible for Cr(VI) retention in soils, and improving the handling and remediation processes.

  3. A radiological control implementation guide

    International Nuclear Information System (INIS)

    Hamley, S.A.

    1993-01-01

    A manual is being developed to explain to line managers how radiological controls are designed and implemented. The manual also fills a gap in the Health Physics literature between textbooks and on-the-floor procedures. It may be helpful to new Health Physicists with little practical experience and to those wishing to improve self-assessment, audit, and appraisal processes. Many audits, appraisals, and evaluations have indicated a need for cultural change, increased vigor and example, and more effective oversight by line management. Inadequate work controls are a frequent and recurring problem identified in occurrence reports and accident investigations. Closer study frequently indicates that many line managers are willing to change and want to achieve excellence, but no effective guidance exists that will enable them to understand and implement a modern radiological control program. The manual is now in draft form and includes information that will be of use to line managers dealing with improving radiological performance and the practical aspects of radiological controls implementation. The manual is expected to be completed by the fall of 1993 and to be used in conjunction with a performance-based self-assessment training program at the Oak Ridge National Laboratory

  4. Experimental investigations of sensor-based surface following tasks by a mobile manipulator

    Energy Technology Data Exchange (ETDEWEB)

    Reister, D.B.; Unseren, M.A.; Baker, J.E.; Pin, F.G.

    1993-10-01

    This paper discusses experimental investigations of the feasibility and requirements of simultaneous external-sensor-based-control of the wheeled platform and the manipulator of a mobile robot. The experiments involve 3-D arbitrary surface following by the manipulator while the platform moves along a predefined trajectory. A variety of concave and convex surfaces were used in the experiments, during which target and measured values of the platform and arm positions and orientations, together with the surface absolute location and normal estimates, were logged at 10 Hz. For all experiments, the data logs showed significant noise, at high frequency, in the calculated surface normal values despite smooth tracking of their target values by the arm and the platform, with typical closed loop delays between target and achieved values of the order of 100 msec. This high-frequency noise in the calculated values is conjectured to result mainly from the arm`s transmission cables compliance and backlash in the spherical wrist gears. On the other hand, the end-effector distance to the surface showed some low frequency errors of the order of {plus_minus}20%The two major sources of these low frequency errors appeared to reside respectively in the low values of the velocity bound and gain parameters utilized to filter the high frequency noise in the calculated normal values prior to using them as input to the arm control, and in the rolling contact of the platform`s rubber-coated wheels on the ground where significant errors in the platform`s positions and orientations can accumulate.

  5. Field and laboratory emission cell automation and control system for investigating surface chemistry reactions

    Science.gov (United States)

    Flemmer, Michael M.; Ham, Jason E.; Wells, J. R.

    2007-01-01

    A novel system [field and laboratory emission cell (FLEC) automation and control system] has been developed to deliver ozone to a surface utilizing the FLEC to simulate indoor surface chemistry. Ozone, humidity, and air flow rate to the surface were continuously monitored using an ultraviolet ozone monitor, humidity, and flow sensors. Data from these sensors were used as feedback for system control to maintain predetermined experimental parameters. The system was used to investigate the chemistry of ozone with α-terpineol on a vinyl surface over 72h. Keeping all other experimental parameters the same, volatile organic compound emissions from the vinyl tile with α-terpineol were collected from both zero and 100ppb(partsper109) ozone exposures. System stability profiles collected from sensor data indicated experimental parameters were maintained to within a few percent of initial settings. Ozone data from eight experiments at 100ppb (over 339h) provided a pooled standard deviation of 1.65ppb and a 95% tolerance of 3.3ppb. Humidity data from 17 experiments at 50% relative humidity (over 664h) provided a pooled standard deviation of 1.38% and a 95% tolerance of 2.77%. Data of the flow rate of air flowing through the FLEC from 14 experiments at 300ml/min (over 548h) provided a pooled standard deviation of 3.02ml/min and a 95% tolerance range of 6.03ml/min. Initial experimental results yielded long term emissions of ozone/α-terpineol reaction products, suggesting that surface chemistry could play an important role in indoor environments.

  6. Acid Aging Effects on Surfaces of PTFE Gaskets Investigated by Thermal Analysis

    Directory of Open Access Journals (Sweden)

    C. Fragassa

    2016-12-01

    Full Text Available This paper investigates the effect of a prolonged acid attack on the surface of PTFE by Thermogravimetric Analysis (TGA and Differential Scanning Calorimetry (DSC. PTFE is very non-reactive, partly because of the strength of carbon–fluorine bonds and for its high crystallinity, and, as a consequence, it is often used in containers and pipework with reactive and corrosive chemicals. The PTFE under analysis is commercialized by two alternative producers in form of Teflon tapes. These tapes are adopted, as gaskets, in process plants where tires moulds are cleaned by acid solutions inside a multistage ultrasonic process. In this case, PTFE shows, in a relatively short operation time, inexplicably phenomena of surface degradation, which could be related, in general terms, to an acid attack. But, even considering the combined effect of ultrasonic waves, temperature, humidity and acid attack, the PTFE properties of resistance nominally exclude the risk of the extreme erosion phenomena as observed. The present experimental research aim at investigating this contradiction. A possible explanation could be related to the presence in the cleaning solution of unexpected fluorides, able to produce fluorinating agents and, thus, degrade carbon-fluorine bonds. Considering more the 300 chemical elements a tire compound consists in, it is really complex to preserve the original chemical composition of the cleaning solution. In this research PTFE samples have been treated with different mixtures of acids with the aim at investigating the different aging effects. The thermal analysis has permitted the experimental characterization of PTFE surface properties after acid attack, providing evidence of the degradation phenomena. In particular, the different acid treatments adopted for accelerating the aging of gaskets have highlighted the different behaviour of the PTFE matrix, but also differences between manufacturers.

  7. Beta Autoradiography. An analytical technique to investigate radionuclides contamination on surface

    International Nuclear Information System (INIS)

    Ficher, P.; Goutelard, F.; Siitari-Kauppi, M.

    2012-01-01

    In decommissioning of old buildings and after disposal of nuclear facilities (materials, glove boxes,...), the inventory of the radioactive contamination of various building materials needs to be obtained in order to fix the working condition for dismantling. The challenge of this study was to classify different building materials of a whole research laboratory that was dedicated to research on organic molecules labeled with H-3 and C-14. The problem of waste classification is essential for safety treatment of waste and also for its cost. The analytical technique of beta autoradiography particularly well known for biological researches has been tested to investigate radionuclides contamination on surface. This technique is mainly interesting for beta and alpha emitters but also sensitive to gamma radiation. The first step of this technique is the deposit of a film on the surface of material to be analyzed. Films can be deposited on the ground or also fixed on the walls or even on the ceiling. The film is a plastic sheet covered with an emulsion containing photostimulable crystals and Eu that is activated when the film is exposed on radioactive source. The exposed films are then scanned with the Cyclone Plus equipment to get a digitized image. This image represents the radioactivity of the surface studied. The possibility to re-use the films is very important to investigate a large area. This autoradiography technique has retained our attention for its sensitivity and moreover the possibility of 2-dimensional investigation has been found as a real advantage. However it remains now as a qualitative technique and new studies must be launched to prove its quantitative potentialities. The high spatial resolution was not as important as in biological observation, and the mm resolution is totally sufficient

  8. Ozone-surface interactions: Investigations of mechanisms, kinetics, mass transport, and implications for indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Glenn Charles [Univ. of California, Berkeley, CA (United States)

    1999-12-01

    In this dissertation, results are presented of laboratory investigations and mathematical modeling efforts designed to better understand the interactions of ozone with surfaces. In the laboratory, carpet and duct materials were exposed to ozone and measured ozone uptake kinetics and the ozone induced emissions of volatile organic compounds. To understand the results of the experiments, mathematical methods were developed to describe dynamic indoor aldehyde concentrations, mass transport of reactive species to smooth surfaces, the equivalent reaction probability of whole carpet due to the surface reactivity of fibers and carpet backing, and ozone aging of surfaces. Carpets, separated carpet fibers, and separated carpet backing all tended to release aldehydes when exposed to ozone. Secondary emissions were mostly n-nonanal and several other smaller aldehydes. The pattern of emissions suggested that vegetable oils may be precursors for these oxidized emissions. Several possible precursors and experiments in which linseed and tung oils were tested for their secondary emission potential were discussed. Dynamic emission rates of 2-nonenal from a residential carpet may indicate that intermediate species in the oxidation of conjugated olefins can significantly delay aldehyde emissions and act as reservoir for these compounds. The ozone induced emission rate of 2-nonenal, a very odorous compound, can result in odorous indoor concentrations for several years. Surface ozone reactivity is a key parameter in determining the flux of ozone to a surface, is parameterized by the reaction probability, which is simply the probability that an ozone molecule will be irreversibly consumed when it strikes a surface. In laboratory studies of two residential and two commercial carpets, the ozone reaction probability for carpet fibers, carpet backing and the equivalent reaction probability for whole carpet were determined. Typically reaction probability values for these materials were 10

  9. Computer-based image analysis in radiological diagnostics and image-guided therapy 3D-Reconstruction, contrast medium dynamics, surface analysis, radiation therapy and multi-modal image fusion

    CERN Document Server

    Beier, J

    2001-01-01

    This book deals with substantial subjects of postprocessing and analysis of radiological image data, a particular emphasis was put on pulmonary themes. For a multitude of purposes the developed methods and procedures can directly be transferred to other non-pulmonary applications. The work presented here is structured in 14 chapters, each describing a selected complex of research. The chapter order reflects the sequence of the processing steps starting from artefact reduction, segmentation, visualization, analysis, therapy planning and image fusion up to multimedia archiving. In particular, this includes virtual endoscopy with three different scene viewers (Chap. 6), visualizations of the lung disease bronchiectasis (Chap. 7), surface structure analysis of pulmonary tumors (Chap. 8), quantification of contrast medium dynamics from temporal 2D and 3D image sequences (Chap. 9) as well as multimodality image fusion of arbitrary tomographical data using several visualization techniques (Chap. 12). Thus, the softw...

  10. Contrast investigations of surface acoustic waves by stroboscopic topography. 1. Orientation contrast

    Energy Technology Data Exchange (ETDEWEB)

    Cerva, H.; Graeff, W.

    1984-03-16

    Surface acoustic waves are investigated by stroboscopic topography using synchrotron radiation from the storage ring DORIS. The observed contrast of the acoustic displacements of the lattice planes has the same periods as the acoustic wave. It is demonstrated that the major part of the contrast is due to orientation contrast of the curved net planes. Intensity maxima correspond to troughs of the acoustic wave, minima to crests. A numerical treatment yielding ray tracing maps, intensity curves as well as focusing conditions which are in quantitative agreement with the experimental data is presented.

  11. Investigation and Evaluation on Influence of Machining (CNC) Conditions on Surface Quality of Paulownia Wood

    OpenAIRE

    Mohammad Aghajani; Abolghasem Khazaian; Mehrab Madhoushi

    2012-01-01

    The aim of this study was to investigate the effective factors on surface quality of paulownia wood during machining by advanced computer numerical controled (CNC) machine. For this aim paulownia logs were provided and were converted to proper sizes (2.5 x 10 x 15 cm) and then air dried. The Variable of this study were cutting speed (8.37 and 15.07 m/s), feeding rate (6 and 12 m/min), cutting depth (1and 5 mm), cutting method (down and up-milling) and cutting pattern (tangential and radial). ...

  12. Investigation of hafnium silicide nanostructures on a Si(100) surface by means of photoelectron diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Fluechter, C.R.; Weier, D. [Experimentelle Physik 1 - Universitaet Dortmund, (Germany); DELTA - Universitaet Dortmund, Maria-Goeppert-Mayer-Str. 2, D 44227 (Germany); Siervo, A. de; Landers, R. [Laboratorio Nacional de Luz Sincrotron, C.P. 6192, (Brazil); Schuermann, M.; Beimborn, A.; Schoenbohm, F.; Dreiner, S.; Westphal, C. [Experimentelle Physik 1 - Universitaet Dortmund, (Germany); Carazzolle, M.F.; Kleiman, G.G. [Inst. de Fisica - Universidade Estadual de Campinas, (Brazil)

    2007-07-01

    Ultrathin films of hafnium were deposited on a silicon sample and annealed at 750 C forming rectangular shaped hafnium silicide islands on the surface. This silicidation process causes the thermal instability of HfO{sub 2} films on silicon substrates. The latter system is under investigation in the field of high-k dielectrics to replace the system SiO{sub 2}/Si(100) in MOSFET devices. We investigated the structure of the HfSi{sub 2} island for different initial film thicknesses of hafnium by means of atomic force microscopy, photoelectron spectroscopy and photoelectron diffraction. Synchrotron light in the soft X-ray regime (h{nu}=180 eV) was used for excitation. The resulting diffraction patterns were compared to calculated patterns of model structures by an R-factor analysis. As a result, we propose a modified zirconium silicide model to describe the structure of the system.

  13. Dry sliding wear investigation of Al6082/Gr metal matrix composites by response surface methodology

    Directory of Open Access Journals (Sweden)

    Pardeep Sharma

    2016-01-01

    Full Text Available The effect of graphite particles on the dry sliding wear behaviour of Al6082 alloy composites produced by conventional stir casting method has been investigated. The percentage of reinforcement was varied from 0% to 12% in a step of 3. The result showed that with the addition of graphite particles micro- and macro-hardness reduced by 11.11% and 10.44%, respectively. The tribological behaviour of composites was investigated by pin on disc apparatus. Percentage reinforcement, load, sliding speed and sliding distance were taken as the process variable. Response surface methodology has been used to plan and analyze the experiment. Results showed that sliding distance is the most influential factor and load is the factor which affects the wear least.

  14. Investigation of the Effect of Dimple Bionic Nonsmooth Surface on Tire Antihydroplaning

    Directory of Open Access Journals (Sweden)

    Haichao Zhou

    2015-01-01

    Full Text Available Inspired by the idea that bionic nonsmooth surfaces (BNSS reduce fluid adhesion and resistance, the effect of dimple bionic nonsmooth structure arranged in tire circumferential grooves surface on antihydroplaning performance was investigated by using Computational Fluid Dynamics (CFD. The physical model of the object (model of dimple bionic nonsmooth surface distribution, hydroplaning model and SST k-ω turbulence model are established for numerical analysis of tire hydroplaning. By virtue of the orthogonal table L16(45, the parameters of dimple bionic nonsmooth structure design compared to the smooth structure were analyzed, and the priority level of the experimental factors as well as the best combination within the scope of the experiment was obtained. The simulation results show that dimple bionic nonsmooth structure can reduce water flow resistance by disturbing the eddy movement in boundary layers. Then, optimal type of dimple bionic nonsmooth structure is arranged on the bottom of tire circumferential grooves for hydroplaning performance analysis. The results show that the dimple bionic nonsmooth structure effectively decreases the tread hydrodynamic pressure when driving on water film and increases the tire hydroplaning velocity, thus improving tire antihydroplaning performance.

  15. [The investigation of humic acid by surface-enhanced Raman spectroscopy].

    Science.gov (United States)

    Zhang, Wen-Juan; Li, Ying; Guo, Jin-Jia; Xiao, Qiong; Yu, Li

    2013-05-01

    Humic acid (HA), which are organic compounds widely existing in the oceans, rivers and soil, has important significance for the environmental monitoring of soil and water. In this paper, ai ming at the problem of Surface-enhanced Raman Spectroscopy (SERS) applying for HA detection in water, the characteristics of the humic acid on silver colloids was studied by means of SERS. The influence of laser irradiation time, HA concentrations and pH value on the surface-enhanced effects of HA were investigated. The experimental results show that the SERS spectra of HA is ideal when the laser irradiation time between 20-30 min. The SERS of different HA concentrations was detected. It was found that the relative intensity at 1 379 cm(-1) increased as a linear function of the concentration of HA with correlation coefficient R2 of 0.993. The SERS of HA was found to be very sensitive to pH, the SERS spectra of HA was very weak at neutral pH, but at acidic pH and alkaline pH a remarkable increase of SERS intensity occurred. The SERS of HA in running water was detected too. The experimental results show that it is feasible to detect HA in natural water by means of surface-enhanced Raman spectroscopy.

  16. Investigation of KDP crystal surface based on an improved bidimensional empirical mode decomposition method

    Science.gov (United States)

    Lu, Lei; Yan, Jihong; Chen, Wanqun; An, Shi

    2018-03-01

    This paper proposed a novel spatial frequency analysis method for the investigation of potassium dihydrogen phosphate (KDP) crystal surface based on an improved bidimensional empirical mode decomposition (BEMD) method. Aiming to eliminate end effects of the BEMD method and improve the intrinsic mode functions (IMFs) for the efficient identification of texture features, a denoising process was embedded in the sifting iteration of BEMD method. With removing redundant information in decomposed sub-components of KDP crystal surface, middle spatial frequencies of the cutting and feeding processes were identified. Comparative study with the power spectral density method, two-dimensional wavelet transform (2D-WT), as well as the traditional BEMD method, demonstrated that the method developed in this paper can efficiently extract texture features and reveal gradient development of KDP crystal surface. Furthermore, the proposed method was a self-adaptive data driven technique without prior knowledge, which overcame shortcomings of the 2D-WT model such as the parameters selection. Additionally, the proposed method was a promising tool for the application of online monitoring and optimal control of precision machining process.

  17. Communication: Anti-icing characteristics of superhydrophobic surfaces investigated by quartz crystal microresonators

    Science.gov (United States)

    Lee, Moonchan; Yim, Changyong; Jeon, Sangmin

    2015-01-01

    We investigated the anti-icing characteristics of superhydrophobic surfaces with various morphologies by using quartz crystal microresonators. Anodic aluminum oxide (AAO) or ZnO nanorods were synthesized directly on gold-coated quartz crystal substrates and their surfaces were rendered hydrophobic via chemical modifications with octyltrichlorosilane (OTS), octadecyltrichlorosilane (ODS), or octadecanethiol (ODT). Four different hydrophobic nanostructures were prepared on the quartz crystals: ODT-modified hydrophobic plain gold (C18-Au), an OTS-modified AAO nanostructure (C8-AAO), an ODS-modified AAO nanostructure (C18-AAO), and ODT-modified ZnO nanorods (C18-ZnO). The water contact angles on the C18-Au, C8-AAO, C18-AAO, and C18-ZnO surfaces were measured to be 91.4°, 147.2°, 156.3°, and 157.8°, respectively. A sessile water droplet was placed on each quartz crystal and its freezing temperature was determined by monitoring the drastic changes in the resonance frequency and Q-factor upon freezing. The freezing temperature of a water droplet was found to decrease with decreases in the water contact radius due to the decreases in the number of active sites available for ice nucleation.

  18. Experimental investigation of surface modified EOF steel slag as coarse aggregate in concrete

    Directory of Open Access Journals (Sweden)

    Y.K. Sabapathy

    2017-10-01

    Full Text Available An experimental work was carried out to study the effect of Energy Optimizing Furnace (EOF steel slag as coarse aggregate replacement in concrete. Surface modification of slag was carried out to seal the surface voids of raw slag aggregates. Quarry dust obtained as an extractive waste from the granite stone quarries has been used as a blending material in this work. After several trials, it was found that a mix proportion of 1:6:14 (cement:quarry dust:slag aggregate was the most suitable mix ratio for the surface modification of the slag aggregates. Various mixes of concrete were prepared with different proportions of modified slag (ranging from 0% to 100% as replacements for aggregates. Three grades of concrete (20 MPa, 30 MPa and 40 MPa were used in the investigation and the concrete mixes were evaluated for compressive strength and splitting tensile strength. It was found that the compressive strength improved for 25 percent replacement of natural coarse aggregates. The splitting tensile strength was found to peak at 25 percent replacement of natural aggregates.

  19. Investigating controls on surface-water quality in streams recharging a karst aquifer

    Science.gov (United States)

    Wong, C. I.; Mahler, B. J.; Musgrove, M.

    2011-12-01

    Understanding controls on surface-water quality is particularly important in karst terrains where recharging surface water can rapidly affect groundwater quality. We investigated controls on water quality under varying hydrologic conditions (drought and wet) and assessed temporal changes in surface water quality from 1974 to 2010 in five streams that recharge the Barton Spring segment of the Edwards aquifer. Sampling was done every 3-4 weeks for 17 months (Nov 2008-Mar 2010) during which hydrologic conditions ranged from exceptional drought to wetter than average (wet conditions). Major-ion concentrations were compared to historical data, and statistical analyses (principle components analysis, PCA) and geochemical inverse modeling (using PHREECQ) were used to identify and quantify controls on surface water compositions under drought and wet conditions. Recent (Nov 2008-Mar 2010) median values for four of the five streams measured for specific conductance (612-813 μS/cm), Cl (24-52 mg/L), Na (11-29 mg/L), and SO4 (61-110 mg/L) were higher relative to the median values measured concurrently in groundwater samples (n=21) from an Edwards aquifer well monitored (specific conductance = 584 μS/cm, Cl = 11 mg/L, Na = 6.5 mg/L, SO4 = 14 mg/L). Recent median values for specific conductance, Na, Cl, and SO4 measured for each of the five streams also were higher than historic (1974-2008) median values measured for same five streams (specific conductance = 410-690 μS/cm; Na = 8.3-23 mg/L; Cl = 13-20 mg/L; and SO4 = 26-58 mg/L). The elevated values measured in the recent stream samples are likely not entirely related to drought conditions. There is no trend in the historic data between the values measured for constituents and climatic conditions, and historic sampling has occurred during past droughts of similar magnitude. The first two factors identified by the PCA explain 70% of the variance observed in recent surface water compositions. Factor 1 is interpreted as dilution

  20. A Metallurgical Investigation of the Direct Energy Deposition Surface Repair of Ferrous Alloys

    Science.gov (United States)

    Marya, Manuel; Singh, Virendra; Hascoet, Jean-Yves; Marya, Surendar

    2018-02-01

    Among additive manufacturing (AM) processes, the direct energy deposition (DED) by laser is explored to establish its applicability for the repair of ferrous alloys such as UNS G41400 low-alloy steel, UNS S41000 martensitic stainless steel, UNS S17400 precipitation-strengthened martensitic stainless steel, and UNS S32750 super-duplex stainless steel. Unlike plating, thermal spray, and conventional cladding weld, DED laser powder deposition offers potential advantages, e.g., thin deposits, limited dilutions, narrow heat-affected zones (HAZ), potentially improved surface properties. In this investigation, all AM deposits were completed with an IREPA CLAD™ system using a powder feed of UNS N06625, an alloy largely selected for its outstanding corrosion resistance. This investigation first addresses topological aspects of AM deposits (including visual imperfections) before focusing on changes in microstructure, microhardness, chemical composition across AM deposits and base materials. It has been established that dense, uniform, hard ( 300 HVN), crack-free UNS N06625-compliant AM deposits of fine dendritic microstructures are reliably produced. However, except for the UNS S32750 steel, a significant martensitic hardening was observed in the HAZs of UNS G41400 ( 650 HVN), UNS S41000 ( 500 HVN), and UNS S17400 ( 370 HVN). In summary, this investigation demonstrates that the DED laser repair of ferrous parts with UNS N06625 may restore damaged surfaces, but it also calls for cautions and complementary investigations for alloys experiencing a high HAZ hardening, for which industry standard recommendations are exceeded and lead to an increased risk of delayed cracking in corrosive environments.

  1. Physics of Radiology

    CERN Document Server

    Johns, Harold Elford

    1983-01-01

    Authority, comprehensivity and a consummate manner of presentation have been hallmarks of The Physics of Radiology since it first saw publication some three decades past. This Fourth Edition adheres to that tradition but again updates the context. It thoroughly integrates ideas recently advanced and practices lately effected. Students and professionals alike will continue to view it, in essence, as the bible of radiological physics.

  2. Radiological concept of spondylodiscitis

    Energy Technology Data Exchange (ETDEWEB)

    Lingg, G.; Karbowski, A.

    1985-07-01

    The destructive discovertebral lesions of ankylosing spondylitis are discussed. Their evaluation in the literature is compared with the newer histologic and radiologic results. The X-ray findings in rheumatoid arthritis are also presented. Using radiographs from 16 of our own patients suffering from ankylosing spondylitis and 5 with rheumatoid arthritis, the analyse the radiological appearance inquestion.

  3. Medical Ethics in Radiology

    International Nuclear Information System (INIS)

    Kim, Kyung Won; Park, Jae Hyung; Yoon, Soon Ho

    2010-01-01

    According to the recent developments in radiological techniques, the role of radiology in the clinical management of patients is ever increasing and in turn, so is the importance of radiology in patient management. Thus far, there have been few open discussions about medical ethics related to radiology in Korea. Hence, concern about medical ethics as an essential field of radiology should be part of an improved resident training program and patient management. The categories of medical ethics related with radiology are ethics in the radiological management of patient, the relationship of radiologists with other medical professionals or companies, the hazard level of radiation for patients and radiologists, quality assurance of image products and modalities, research ethics, and other ethics issues related to teleradiology and fusion imaging. In order to achieve the goal of respectful progress in radiology as well as minimizing any adverse reaction from other medical professions or society, we should establish a strong basis of medical ethics through the continuous concern and self education

  4. Radiological concept of spondylodiscitis

    International Nuclear Information System (INIS)

    Lingg, G.; Karbowski, A.

    1985-01-01

    The destructive discovertebral lesions of ankylosing spondylitis are discussed. Their evaluation in the literature is compared with the newer histologic and radiologic results. The X-ray findings in rheumatoid arthritis are also presented. Using radiographs from 16 of our own patients suffering from ankylosing spondylitis and 5 with rheumatoid arthritis, the analyse the radiological appearance inquestion. (orig.) [de

  5. Characterization of radiological emergencies

    International Nuclear Information System (INIS)

    Chester, C.V.

    1986-01-01

    This paper identifies conditions that should be considered by the designers of mobile teleoperator equipment intended for service in radiological emergencies. We include a definition of radiological emergency and a taxonomy of emergencies. We will indicate the range of operating conditions that an equipment designer should consider and the type of operations that his machine might be expected to perform. 2 refs., 1 tab

  6. Automated Surface Classification of SRF Cavities for the Investigation of the Influence of Surface Properties onto the Operational Performance

    International Nuclear Information System (INIS)

    Wenskat, Marc

    2015-07-01

    Superconducting niobium radio-frequency cavities are fundamental for the European XFEL and the International Linear Collider. To use the operational advantages of superconducting cavities, the inner surface has to fulfill quite demanding requirements. The surface roughness and cleanliness improved over the last decades and with them, the achieved maximal accelerating field. Still, limitations of the maximal achieved accelerating field are observed, which are not explained by localized geometrical defects or impurities. The scope of this thesis is a better understanding of these limitations in defect free cavities based on global, rather than local, surface properties. For this goal, more than 30 cavities underwent subsequent surface treatments, cold RF tests and optical inspections within the ILC-HiGrade research program and the XFEL cavity production. An algorithm was developed which allows an automated surface characterization based on an optical inspection robot. This algorithm delivers a set of optical surface properties, which describes the inner cavity surface. These optical surface properties deliver a framework for a quality assurance of the fabrication procedures. Furthermore, they shows promising results for a better understanding of the observed limitations in defect free cavities.

  7. Numerical and experimental investigation of the 3D free surface flow in a model Pelton turbine

    International Nuclear Information System (INIS)

    Fiereder, R; Riemann, S; Schilling, R

    2010-01-01

    This investigation focuses on the numerical and experimental analysis of the 3D free surface flow in a Pelton turbine. In particular, two typical flow conditions occurring in a full scale Pelton turbine - a configuration with a straight inlet as well as a configuration with a 90 degree elbow upstream of the nozzle - are considered. Thereby, the effect of secondary flow due to the 90 degree bending of the upstream pipe on the characteristics of the jet is explored. The hybrid flow field consists of pure liquid flow within the conduit and free surface two component flow of the liquid jet emerging out of the nozzle into air. The numerical results are validated against experimental investigations performed in the laboratory of the Institute of Fluid Mechanics (FLM). For the numerical simulation of the flow the in-house unstructured fully parallelized finite volume solver solver3D is utilized. An advanced interface capturing model based on the classic Volume of Fluid method is applied. In order to ensure sharp interface resolution an additional convection term is added to the transport equation of the volume fraction. A collocated variable arrangement is used and the set of non-linear equations, containing fluid conservation equations and model equations for turbulence and volume fraction, are solved in a segregated manner. For pressure-velocity coupling the SIMPLE and PISO algorithms are implemented. Detailed analysis of the observed flow patterns in the jet and of the jet geometry are presented.

  8. A first principles investigation of the oxygen adsorption on Zr(0001) surface using cluster expansions

    Science.gov (United States)

    Samin, Adib J.; Taylor, Christopher D.

    2017-11-01

    The design of corrosion resistant zircalloys is important for a variety of technological applications ranging from medicine to the nuclear industry. Since corrosion resistance is mainly attributed to the formation of a surface oxide layer, developing a detailed understanding of this process may assist in future corrosion resistance design. In this work, we conduct a systematic multi-scale investigation of the early stages of oxide formation. This was accomplished by first using a database of fully relaxed DFT calculations to build a cluster-expansion description of the potential function. The developed potential was reasonably good at predicting DFT energies as evidenced by the cross-validation score of 4.4 meV/site. The effective cluster expansion parameters were indicative of repulsive adsorbate interactions in the adlayer in agreement with the literature. The potential then allowed for a systematic investigation of the oxygen configurations on the Zr(0001) surface via Monte Carlo simulations. The adsorption energy was recorded as a function of coverage and an increasing trend was observed in agreement with DFT predictions and the repulsive nature of interactions in the adlayer. The convex hull diagram was recorded indicating the most stable configuration to occur around a coverage of 0.6 ML. The adsorption isotherm was also recorded and contrasted for two temperatures relevant for different applications.

  9. Investigation of 10 herbicides in surface waters of a horticultural production catchment in southeastern Australia.

    Science.gov (United States)

    Allinson, Graeme; Bui, AnhDuyen; Zhang, Pei; Rose, Gavin; Wightwick, Adam M; Allinson, Mayumi; Pettigrove, Vincent

    2014-10-01

    Herbicides are regularly applied in horticultural production systems and may migrate off-site, potentially posing an ecological risk to surface waterways. However, few studies have investigated the levels and potential ecotoxicological impact of herbicides in horticultural catchments in southern Australia. This study investigated the presence of 10 herbicides at 18 sites during a 5-month period in horticulturally important areas of the Yarra Valley in southeastern Australia. Seven of the 10 herbicides were detected in the streams, in 39 % of spot water samples, in 25 % of surface sediment samples, and in >70 % of the passive sampler systems deployed. Few samples contained residues of ≥2 herbicides. Simazine was the herbicide most frequently detected in water, sediment, and passive sampler samples and had the highest concentrations in water (0.67 μg/L) and sediment (260 μg/kg dry weight). Generally the concentrations of the herbicides detected were several orders of magnitude lower than reported ecotoxicological effect values, including those for aquatic plants and algae, suggesting that concentrations of individual chemicals in the catchment were unlikely to pose an ecological risk. However, little is known about the combined effects of simultaneous, low-level exposure of multiple herbicides of the same mode of action on Australian aquatic organisms nor their contribution when found in mixtures with other pesticides. Further research is required to adequately assess the risk of pesticides in Victorian aquatic environments.

  10. Investigation of structural transformations in surface layer of phosphate glasses incorporating radiactive wastes

    International Nuclear Information System (INIS)

    Aloj, A.S.; Kolycheva, T.I.; Trofimenko, A.V.; Shashukov, E.A.

    1985-01-01

    The objective of the paper was to clarify possibilities of detection of structural transformations initial stages on the surface of phosphate glasses using the method of infrared reflection spectroscopy. Phase composition of crystalline compounds formed in surface glass layer is determined by the method of X-ray diffraction. All experiments were performed using sodium alumophosphate glass comprising the model mixture of fission product of the following compostion (mass%): Na 2 O-22.0, Al 2 O 3 -14.0, P 2 O 5 -50.0, Fe 2 O 3 -3.5, Cs 2 O-3.5, SrO-3.0, Ln 2 O 3 -4.0, where Ln 2 O 3 is a mixture of cerium, lanthanum and europium oxides. Sample preparation were carried out by molten glass deposition on platinum forms 15mm in diameter and 4mm thick. Glasses were treated within the 600-400deg.C temperature range. Fixing of processes accompanied by structural transformations was accomplished the method of rapid cooling. It has been shown that phase transformations, taking place in investigated phosphate glasses under the action of heat, result in deterioration of chemical properties. Analysis of IR spectra has revealed that emergence of structural transformations in surface layer of investigated glasses results in variation of a ratio of 1060 and 1140cm - 1 reflection band intensities. Experimental dependences of the time of beginning of variation of 1060 and 1140cm - 1 bands relative intensity on temperature are presented. Insemilogarithmic coordinates this dependence has a straight line form within the 600-400 deg C temperature range and is desc ribed by the following formular: lg r=-7.41+5.70x10 3 x1/T, where r is the time of process beginning, h. Extrapolation of established to the region of low temperature is shown. Competence of such extrapolation may be confirmed in the course of further experiments

  11. Investigating surface and subsurface physical properties of small bodies from light scattering observations and simulations

    Science.gov (United States)

    Levasseur-Regourd, A. C.; Hadamcik, E.; Lasue, J.; Renard, J. B.

    Investigating surface and subsurface physical properties of small bodies from light scattering observations and simulations A.C. Levasseur-Regourd (1), E. Hadamcik (1), J. Lasue (1), J.B. Renard (2) (1) Université Pierre et Marie Curie-Paris6, UMR 7620, Aéronomie, BP-3, Verrières, 91371 France, (2) LPCE-CNRS, 3A av. Recherche Scientifique, Orléans, F-45071 France Investigating surface and subsurface physical properties of asteroids and comet nuclei is of major interest to i) assess future space missions and ii) constrain formation and evolution models. Our purpose is to infer such properties from the properties of solar light scattered by such media. We will first summarize recent remote polarimetric observations of small bodies, which confirm the main characteristics of the variation of the linear polarization of solar scattered light in the visible domain with the scattering geometry and the wavelength (1). To interpret such characteristics in terms of physical properties of the regoliths (e.g. albedo, size distribution, complex refractive index, porosity), experimental and numerical simulations on various types of particles and aggregates are mandatory, together with some comparisons between experimental and numerical simulations (2,3). We will thus present recent results of such simulations (for dust around bright comets, for core-mantle particles, for loose deposited transparent and dark materials), and point out the trends already suggested by this approach. Finally, we will mention future key observations and elaborate simulations, which could solve open questions about surface and subsurface properties of small bodies. References 1. Levasseur-Regourd et al., ASR 37, 161, 2006. 2. Hadamcik et al., JQSRT 100, 143, 2006. 3. Lasue et al., JQSRT 100, 220, 2006.

  12. Investigation of integrin expression on the surface of osteoblast-like cells by atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Caneva Soumetz, Federico [Department of Communication, Computer and System Sciences, University of Genova, Via Opera Pia, 13-16145 Genova (Italy); Saenz, Jose F. [Biophysical and Electronic Engineering Department, University of Genova, Via All' Opera Pia 11a, 16145 Genova (Italy); Pastorino, Laura; Ruggiero, Carmelina [Department of Communication, Computer and System Sciences, University of Genova, Via Opera Pia, 13-16145 Genova (Italy); Nosi, Daniele [Department of Anatomy, Histology and Forensic Medicine, Bio-photonic Laboratory, University of Florence, viale Morgagni, 85 Firenze, CAP 50134 Florence (Italy); Raiteri, Roberto, E-mail: rr@unige.it [Biophysical and Electronic Engineering Department, University of Genova, Via All' Opera Pia 11a, 16145 Genova (Italy)

    2010-03-15

    The transforming growth factor {beta}1 (TGF-{beta}1) is a human cytokine which has been demonstrated to modulate cell surface integrin repertoire. In this work integrin expression in response to TGF-{beta}1 stimulation has been investigated on the surface of human osteoblast-like cells. We used atomic force microscopy (AFM) and confocal laser scanning microscopy to assess integrin expression and to evaluate their distribution over the dorsal side of the plasma membrane. AFM probes have been covalently functionalised with monoclonal antibodies specific to the {beta}1 integrin subunit. Force curves have been collected in order to obtain maps of the interaction between the immobilized antibody and the respective cell membrane receptors. Adhesion peaks have been automatically detected by means of an ad hoc developed data analysis software. The specificity of the detected interactions has been assessed by adding free antibody in the solution and monitoring the dramatic decrease in the recorded interactions. In addition, the effect of TGF-{beta}1 treatment on both the fluorescence signal and the adhesion events has been tested. The level of expression of the {beta}1 integrin subunit was enhanced by TGF-{beta}1. As a further analysis, the adhesion force of the single living cells to the substrate was measured by laterally pushing the cell with the AFM tip and measuring the force necessary to displace it. The treatment with TGF-{beta}1 resulted in a decrease of the cell/substrate adhesion force. Results obtained by AFM have been validated by confocal laser scanning microscopy thus demonstrating the high potential of the AFM technique for the investigation of cell surface receptors distribution and trafficking at the nanoscale.

  13. Development of a Linear Ion Trap Mass Spectrometer (LITMS) Investigation for Future Planetary Surface Missions

    Science.gov (United States)

    Brinckerhoff, W.; Danell, R.; Van Ameron, F.; Pinnick, V.; Li, X.; Arevalo, R.; Glavin, D.; Getty, S.; Mahaffy, P.; Chu, P.; hide

    2014-01-01

    Future surface missions to Mars and other planetary bodies will benefit from continued advances in miniature sensor and sample handling technologies that enable high-performance chemical analyses of natural samples. Fine-scale (approx.1 mm and below) analyses of rock surfaces and interiors, such as exposed on a drill core, will permit (1) the detection of habitability markers including complex organics in association with their original depositional environment, and (2) the characterization of successive layers and gradients that can reveal the time-evolution of those environments. In particular, if broad-based and highly-sensitive mass spectrometry techniques could be brought to such scales, the resulting planetary science capability would be truly powerful. The Linear Ion Trap Mass Spectrometer (LITMS) investigation is designed to conduct fine-scale organic and inorganic analyses of short (approx.5-10 cm) rock cores such as could be acquired by a planetary lander or rover arm-based drill. LITMS combines both pyrolysis/gas chromatograph mass spectrometry (GCMS) of sub-sampled core fines, and laser desorption mass spectrometry (LDMS) of the intact core surface, using a common mass analyzer, enhanced from the design used in the Mars Organic Molecule Analyzer (MOMA) instrument on the 2018 ExoMars rover. LITMS additionally features developments based on the Sample Analysis at Mars (SAM) investigation on MSL and recent NASA-funded prototype efforts in laser mass spectrometry, pyrolysis, and precision subsampling. LITMS brings these combined capabilities to achieve its four measurement objectives: (1) Organics: Broad Survey Detect organic molecules over a wide range of molecular weight, volatility, electronegativity, concentration, and host mineralogy. (2) Organic: Molecular Structure Characterize internal molecular structure to identify individual compounds, and reveal functionalization and processing. (3) Inorganic Host Environment Assess the local chemical

  14. Investigation of integrin expression on the surface of osteoblast-like cells by atomic force microscopy

    International Nuclear Information System (INIS)

    Caneva Soumetz, Federico; Saenz, Jose F.; Pastorino, Laura; Ruggiero, Carmelina; Nosi, Daniele; Raiteri, Roberto

    2010-01-01

    The transforming growth factor β1 (TGF-β1) is a human cytokine which has been demonstrated to modulate cell surface integrin repertoire. In this work integrin expression in response to TGF-β1 stimulation has been investigated on the surface of human osteoblast-like cells. We used atomic force microscopy (AFM) and confocal laser scanning microscopy to assess integrin expression and to evaluate their distribution over the dorsal side of the plasma membrane. AFM probes have been covalently functionalised with monoclonal antibodies specific to the β1 integrin subunit. Force curves have been collected in order to obtain maps of the interaction between the immobilized antibody and the respective cell membrane receptors. Adhesion peaks have been automatically detected by means of an ad hoc developed data analysis software. The specificity of the detected interactions has been assessed by adding free antibody in the solution and monitoring the dramatic decrease in the recorded interactions. In addition, the effect of TGF-β1 treatment on both the fluorescence signal and the adhesion events has been tested. The level of expression of the β1 integrin subunit was enhanced by TGF-β1. As a further analysis, the adhesion force of the single living cells to the substrate was measured by laterally pushing the cell with the AFM tip and measuring the force necessary to displace it. The treatment with TGF-β1 resulted in a decrease of the cell/substrate adhesion force. Results obtained by AFM have been validated by confocal laser scanning microscopy thus demonstrating the high potential of the AFM technique for the investigation of cell surface receptors distribution and trafficking at the nanoscale.

  15. Calcium pyroxenes at Mercurian surface temperatures: investigation of in-situ emissivity spectra and thermal expansion

    Science.gov (United States)

    Ferrari, S.; Nestola, F.; Helbert, J.; Maturilli, A.; D'Amore, M.; Alvaro, M.; Domeneghetti, M.; Massironi, M.; Hiesinger, H.

    2013-12-01

    The European Space Agency and Japan Aerospace Agency mission to Mercury, named BepiColombo, will carry on board the Mercury Radiometer and Thermal Infrared Spectrometer (MERTIS) that will be able to provide surface Thermal Infra-Red (TIR) emissivity spectra from 7 to 14 μm. This range of wavelengths is very useful to identify the fine-scale structural properties of several silicates. For mineral families as pyroxenes, the emissivity peak positions are good indicators of the composition. A complication in the interpretation of MERTIS data could arise from the extreme daily surface temperature range of Mercury (70 to 725 K) that significantly affects the crystal structure and density of minerals and consequently should affect the TIR spectral signature of each single mineral present on the surface of the planet. In preparation for the MERTIS data analysis, we are extensively investigating at high temperatures conditions several mineral phases potentially detectable on the surface of Mercury. Two C2/c augitic pyroxenes, with constant calcium content and very different magnesium to iron ratio, were studied by in situ high-temperature thermal infrared spectroscopy (up to 750 K) and in situ high-temperature single-crystal X-ray diffraction (up to 770 K). The emissivity spectra of the two samples show similar band center shifts of the main three bands toward lower wavenumbers with increasing temperature. Our results indicate that the center position of bands 1 and 2 is strictly dependent on temperature, whereas the center position of band 3 is a strong function of the composition regardless the temperature. These data suggest that MERTIS spectra will be able to provide indications of C2/c augitic pyroxene with different magnesium contents and will allow a correct interpretation independently on the spectra acquisition temperature.

  16. HYDROLOGIC AND FEATURE-BASED SURFACE ANALYSIS FOR TOOL MARK INVESTIGATION ON ARCHAEOLOGICAL FINDS

    Directory of Open Access Journals (Sweden)

    K. Kovács

    2012-07-01

    Full Text Available The improvement of detailed surface documentation methods provides unique tool mark-study opportunities in the field of archaeological researches. One of these data collection techniques is short-range laser scanning, which creates a digital copy of the object’s morphological characteristics from high-resolution datasets. The aim of our work was the accurate documentation of a Bronze Age sluice box from Mitterberg, Austria with a spatial resolution of 0.2 mm. Furthermore, the investigation of the entirely preserved tool marks on the surface of this archaeological find was also accomplished by these datasets. The methodology of this tool mark-study can be summarized in the following way: At first, a local hydrologic analysis has been applied to separate the various patterns of tools on the finds’ surface. As a result, the XYZ coordinates of the special points, which represent the edge lines of the sliding tool marks, were calculated by buffer operations in a GIS environment. During the second part of the workflow, these edge points were utilized to manually clip the triangle meshes of these patterns in reverse engineering software. Finally, circle features were generated and analysed to determine the different sections along these sliding tool marks. In conclusion, the movement of the hand tool could be reproduced by the spatial analysis of the created features, since the horizontal and vertical position of the defined circle centre points indicated the various phases of the movements. This research shows an exact workflow to determine the fine morphological structures on the surface of the archaeological find.

  17. RCRA Facility Investigation report for Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Volume 4, Technical memorandums 06-03A, 06-04A, 06-05A, and 06-08A

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, R. C.; Lewis, K. K.

    1991-09-01

    This report presents data and information related to remedial investigation studies for Oak Ridge National Laboratory (ORNL). Information is included on a soil gas survey, surface radiological investigations of waste areas, and well installation for ground water monitoring. (CBS)

  18. Investigation of radiological emergencies by the IPEN-CNEN/SP during the years 2001 to 2010; Averiguacoes de emergencias radiologicas pelo IPEN-CNEN/SP nos anos de 2001 a 2010

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Fabio Fumio; Mitake, Malvina Boni, E-mail: ffsuzuki@ipen.b, E-mail: mbmitake@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-10-26

    The Brazilian National Nuclear Energy Commission maintain, in each of its unities, a technical team for investigation and initial response to radiological and nuclear emergency situations which can occur outside of its installations. At the Sao Paulo state, Brazil, that task is accomplished by the Radioprotection Management (GRP) of the Instituto de Pesquisas Energeticas e Nucleares, IPEN-CNEN/SP, Brazil. This paper shows the results obtained by the GRP, analysing which entities action the system, the nature of the event, the involved type of radiation source and the geographical distribution of occurrences in the state. During the period between 2001 and 2010, the GRP attended to 98 notifications, and the entity which the most action the system was the Fire Department. The radionuclide of most incidence was the Am-241, mainly because of radioactive lightning-arrester, followed of radionuclides used in nuclear medicine such as Mo-99/Tc-99m and I-131

  19. EarthShape: A Strategy for Investigating the Role of Biota on Surface Processes

    Science.gov (United States)

    Übernickel, Kirstin; Ehlers, Todd Alan; von Blanckenburg, Friedhelm; Paulino, Leandro

    2017-04-01

    EarthShape - "Earth surface shaping by biota" is a 6-year priority research program funded by the German science foundation (DFG-SPP 1803) that performs soil- and landscape-scale critical zone research at 4 locations along a climate gradient in Chile, South America. The program is in its first year and involves an interdisciplinary collaboration between geologists, geomorphologists, ecologists, soil scientists, microbiologists, geophysicists, geochemists, hydrogeologists and climatologists including 18 German and 8 Chilean institutions. EarthShape is composed of 4 research clusters representing the process chain from weathering of substrate to deposition of eroded material. Cluster 1 explores micro-biota as the "weathering engine". Investigations in this cluster quantify different mechanisms of biogenic weathering whereby plants, fungi, and bacteria interact with rock in the production of soil. Cluster 2 explores bio-mediated redistribution of material within the weathering zone. Studies in this cluster focus on soil catenas along hill slope profiles to investigate the modification of matter along its transport path. Cluster 3 explores biotic modulation of erosion and sediment routing at the catchment scale. Investigations in this cluster explore the effects of vegetation cover on solute and sediment transport from hill slopes to the channel network. Cluster 4 explores the depositional legacy of coupled biogenic and Earth surface systems. This cluster investigates records of vegetation-land surface interactions in different depositional settings. A final component of EarthShape lies in the integration of results from these 4 clusters using numerical models to bridging between the diverse times scales used by different disciplines. The Chilean Coastal Cordillera between 25° and 40°S was selected to carry out this research because its north-south orientation captures a large ecological and climate gradient. This gradient ranges from hyper-arid (Atacama desert) to

  20. Patient exposure evaluation in Romanian radiological departments

    International Nuclear Information System (INIS)

    Girjoaba, O.; Cucu, A.

    2012-01-01

    Purpose: A nation-wide evaluation of ionizing radiation exposure of the Romanian population due to the radiological examinations is performed in accordance with European Directive 97/43 EURATOM implemented in national regulations. Method: The study is applied to the collected data from radiological departments from Romanian hospitals during 2010. The radiological examinations were grouped in three categories: conventional diagnostic radiology, interventional radiology and computed tomography. The annual collective dose was determined from the reported data about the mean effective doses and the frequency for each type of radiological examination, in conformity with the national regulations. Regarding the frequency aspects, the results include the age and gender distributions. Major results: More then 6 million radiological examinations were performed in 2010, Romania having a population about of 20.3 million inhabitants. The collective effective dose for 2010 resulted from the study is 152 mSv per 1000 inhabitants. Conclusions: Medical practitioners must select the best medical imaging investigation for each clinical case taking into account the importance of keeping the patient dose as low as possible. Medical physicists should be strongly involved in the establishing of the dosimetry procedures. (author)

  1. Investigation of the radiological safety concerns and medical history of the late Joseph T. Harding, former employee of the Paducah Gaseous Diffusion Plant

    CERN Document Server

    Vallario, E J

    1981-01-01

    An ex-employee's claims that inadequate enforcement of radiation safety regulations allowed excess radiation exposure thereby causing his deteriorating health was not substantiated by a thorough investigation.

  2. Investigation of the radiological safety concerns and medical history of the late Joseph T. Harding, former employee of the Paducah Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    Vallario, E.J.; Wolfe, H.R.

    1981-01-01

    An ex-employee's claims that inadequate enforcement of radiation safety regulations allowed excess radiation exposure thereby causing his deteriorating health was not substantiated by a thorough investigation

  3. Investigation of the radiological safety concerns and medical history of the late Joseph T. Harding, former employee of the Paducah Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    Vallario, E.J.; Wolfe, H.R.

    1981-03-01

    An ex-employee's claims that inadequate enforcement of radiation safety regulations allowed excess radiation exposure thereby causing his deteriorating health was not substantiated by a thorough investigation

  4. Investigations of the Electronic Properties and Surface Structures of Aluminium-Rich Quasicrystalline Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Barrow, Jason A. [Iowa State Univ., Ames, IA (United States)

    2003-01-01

    The work presented in this dissertation has investigated three distinct areas of interest in the field of quasicrystals: bulk structure, transport properties, and electronic structure. First, they have described the results of a study which explored the fundamental interactions between the atomic species of the icosahedral Al-Pd-Mn quasicrystal. The goal of this work was to determine whether the pseudo-MacKay or Bergman type clusters have a special stability or are merely a geometric coincidence. This was carried out by using laser vaporization to produce gas-phase metal clusters, which were analyzed using time-of-flight mass spectrometry. Both the kinetic and thermodynamic stabilities of the clusters were probed. The data indicated no special stability for either pseudo-MacKay or Bergman type clusters as isolated units. This, however, is not proof that these clusters are simply a geometric coincidence. It is possible that such clusters only have stability in the framework of the bulk matrix and do not exist as isolated units. Next, they have reported their investigations of the bulk thermal transport properties of a decagonal Al-Ni-Co two dimensional quasicrystal in the temperature range 373K-873K. The properties of a sample oriented along the periodic axis and another oriented along the aperiodic axis were measured. A high degree of anisotropy was observed between the aperiodic and periodic directions. Additionally, the properties were measured for a sample miscut to an orientation 45° off-axis. The properties of the miscut sample were shown to have good agreement with a theoretical model used to describe thermal transport in metallic single crystals. This model only considers thermal transport by a free-electron gas; therefore, agreement with experimental data suggests the validity of the Drude free-electron model for the decagonal Al-Ni-Co at these temperatures. Consequently, the observed anisotropy may be adequately described using classical transport

  5. Radiological chronometry of uranium metal samples

    International Nuclear Information System (INIS)

    Meyers, L.A.; Stalcup, A.M.; Glover, S.E.; Spitz, H.B.; LaMont, S.P.

    2014-01-01

    Radiological chronometry is an important tool in nuclear forensics that uses several methods to determine the length of time that has elapsed since a material was last purified. One of the chronometers used in determining the age of metallic uranium involves measuring the fractional ingrowth of 230 Th from its parent 234 U with the assumption that the uranium metal contained no impurities, especially thorium, when it was purified. The affects of different etching procedures were evaluated for the removal of surface oxidation with three different types of uranium metal samples to determine whether the etching procedure affects the radiological age. The sample treated with a rigorous etching procedure had exhibited the most reliable radiological age while less rigorous etching yields a radiological age from 15 years to hundreds of years older than the known age. Any excess thorium on the surface of a uranium metal sample presents a bias in age determination and the sample will appear older than the true age. Although this research demonstrates the need for rigorous surface etching, a bias in the radiological age could have arisen if the uranium in the metal was heterogeneously distributed. (author)

  6. Radiological exposure assessment from soil, underground and surface water in communities along the coast of a shallow water offshore oilfield in Ghana.

    Science.gov (United States)

    Kpeglo, D O; Mantero, J; Darko, E O; Emi-Reynolds, G; Akaho, E H K; Faanu, A; Garcia-Tenorio, R

    2015-02-01

    Radiometric determinations have been carried out to assess public exposure to radioactivity for communities along the coast of a shallow water offshore oilfield in Ghana (which started their operations recently) in order to establish baseline data using alpha spectrometry after radiochemical separation and non-destructive gamma spectrometry. The average activity concentrations of (234)U, (238)U, (230)Th and (232)Th by alpha-particle spectrometry and of (226)Ra, (228)Ra, (228)Th, (40)K, (210)Pb, (234)Th and (137)Cs by gamma-ray spectrometry were determined in the soil samples. The activity concentrations of (234)U, (238)U, (230)Th and (232)Th were determined in the water samples by alpha-particle spectrometry and of (226)Ra by liquid scintillation counting. The total annual effective dose to the public was estimated from the measured activity concentrations and this was clearly below the International Commission on Radiological Protection (ICRP) reference level of 1 mSv y(-1) for public exposure control. In addition, the estimated values of Raeq, Hex and Hin were all lower than the recommended acceptable values and the mean values of gross alpha and gross beta determinations performed for all the water samples give values that were all below the Ghana Standards Authority and World Health Organization recommended guideline values for drinking water quality. The results obtained show insignificant public exposure to radioactivity. However, this study provides important information for future studies on subsequent evaluations of the possible future environmental contamination due to activities of the oil industry in Ghana. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Investigating the effects of membrane deformability on artificial capsule adhesion to the functionalized surface.

    Science.gov (United States)

    Balsara, Hiren D; Banton, Rohan J; Eggleton, Charles D

    2016-10-01

    Understanding, manipulating and controlling cellular adhesion processes can be critical in developing biomedical technologies. Adhesive mechanisms can be used to the target, pattern and separate cells such as leukocytes from whole blood for biomedical applications. The deformability response of the cell directly affects the rolling and adhesion behavior under viscous linear shear flow conditions. To that end, the primary objective of the present study was to investigate numerically the influence of capsule membrane's nonlinear material behavior (i.e. elastic-plastic to strain hardening) on the rolling and adhesion behavior of representative artificial capsules. Specifically, spherical capsules with radius of [Formula: see text] were represented using an elastic membrane governed by a Mooney-Rivlin strain energy functions. The surfaces of the capsules were coated with P-selectin glycoprotein-ligand-1 to initiate binding interaction with P-selectin-coated planar surface with density of [Formula: see text] under linear shear flow varying from 100 to [Formula: see text]. The numerical model is based on the Immersed Boundary Method for rolling of deformable capsule in shear flow coupled with Monte Carlo simulation for receptor/ligand interaction modeled using Bell model. The results reveal that the mechanical properties of the capsule play an important role in the rolling behavior and the binding kinetics between the capsule contact surface and the substrate. The rolling behavior of the strain hardening capsules is relatively smoother and slower compared to the elastic-plastic capsules. The strain hardening capsules exhibits higher contact area at any given shear rate compared to elastic-plastic capsules. The increase in contact area leads to decrease in rolling velocity. The capsule contact surface is not in complete contact with the substrate because of thin lubrication film that is trapped between the capsule and substrate. This creates a concave shape on the bottom

  8. Investigating the Physical Basis of Amorphous Precursor Transformation to Calcite Using Patterned Alkanethiol Surfaces

    Science.gov (United States)

    Wang, D.; Wallace, A.; Han, T. Y.; Lee, J. R.; Hailey, P. D.; de Yoreo, J. J.; Dove, P. M.

    2007-12-01

    Increasing evidence from X-ray Absorption Spectroscopy and Environmental Scanning Electron Microscopy (ESEM) studies of biominerals extracted from calcifying organisms show that amorphous calcium carbonate (ACC) plays a key role in the initial formation of carbonate minerals and in shaping them into complex morphologies. Echinoderms and possibly a wide variety of other organisms, use ACC as a precursor phase. The ACC is first formed within spatial and temporally controlled environments such as vesicles, followed by a subsequent onset of mineralization that transforms the precursor into a fully crystalline material. Recent studies on sea urchin embryos have shown that during this transformation, ACC develops short-range order that resembles calcite before fully crystallizing. While this "non-traditional" process is recognized, the mechanisms and factors that govern this transformation remain poorly understood. Of particular interest are the roles of water, and the functional group chemistry of surfaces and macromolecules within mineralization environments. To investigate these questions, we have developed an experimental approach using ESEM that allows us to control impurity concentration, surface functionality and water content through the degree of water condensation. Patterned self-assembled monolayers (SAM) of hydrophilic moieties with domains of approximately 25 microns in diameter are used to form an array of micro-reactors. ACC particles with known composition are then deposited on the patterns. Condensing water in the ESEM initializes the transformation of ACC to calcite. Our results show that in saturated water vapor, ACC swells, but no obvious faceting of the material occurs. It is only in bulk water, via dissolution/crystallization, where the calcite grown on carboxyl-terminated surfaces is found with the often-observed \\{013\\} nucleation face. We use this insight to understand the role of the different chemical moieties on ACC to calcite transformation

  9. Investigation of surface and sub-surface damage in high quality synthetic diamonds by X-ray reflectivity and grazing incidence in-plane diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Bussone, Genziana; Lafford, Tamzin A.; Masiello, Fabio; Carbone, Gerardina; Schuelli, Tobias U.; Rommeveaux, Amparo Vivo; Haertwig, Juergen [European Synchrotron Radiation Facility, 6, Rue Jules Horowitz, BP 220, 38043 Grenoble Cedex 9 (France); Gibaud, Alain [Laboratoire PEC, Universite du Maine le Mans, Avenue Olivier Messiaen, 72 085 Le Mans (France); Connell, Simon H. [University of Johannesburg, cnr Kingsway Ave and University Rd, Auckland Park, 2006, Johannesburg (South Africa); Wormington, Matthew [Jordan Valley Semiconductors Inc., 8601 Cross Park Drive, Suite 200, Austin, TX 78754-4578 (United States)

    2011-11-15

    High quality single-crystal synthetic diamond is the most suitable material for selected X-ray optical applications in the latest generation X-ray light sources. Excellent heat handling properties, as well as low absorption, coupled with high perfection in the crystal bulk and very good surface quality, are crucial for such applications. In recent years, some progress has been made in the fields of surface treatments and growth techniques. Conventional scaife polishing is largely ineffective on the diamond (111) surface. To overcome this disadvantage, one possibility is to use the Hot Metal polishing technique. An investigation of surface and sub-surface damage of Hot Metal polished and cleaved surfaces, has been carried out using depth-sensitive non-destructive X-ray techniques. The near surface crystalline quality was studied as a function of depth using in-plane grazing incidence X-ray diffraction. Additionally, X-ray reflectivity was used to investigate the density, thickness and roughness of near-surface layers. The measurements enable us to estimate the thickness of the affected sub-surface layer. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Infrared spectral investigations of UV irradiated nucleobases adsorbed on mineral surfaces

    Science.gov (United States)

    Fornaro, Teresa; Brucato, John Robert; Pace, Emanuele; Guidi, Mariangela Cestelli; Branciamore, Sergio; Pucci, Amaranta

    2013-09-01

    The interaction between electromagnetic radiation and bio-molecules in heterogeneous environments is a prebiotically relevant process. Minerals may have a pivotal role in the prebiotic evolution of complex chemical systems, mediating the effects of electromagnetic radiation, influencing the photostability of bio-molecules, catalyzing important chemical reactions and/or protecting molecules against degradation. In particular, nucleobases are relevant bio-molecules to investigate both in the prebiotic context, because they are coding components of nucleic acids, and from the standpoint of the survival of biological systems in space conditions. Several studies on the photodynamics of nucleobases suggest that their structure could have been naturally selected for the ability to dissipate electronic energy through ultrafast photophysical decay. Considering the putative involvement of minerals in the prebiotic chemistry, it is necessary to study the photostability of nucleobases under space conditions in the presence of mineral matrices, to investigate both the prebiotic processes that might have had a role in the development of the first living entities on Earth and the physical and chemical processes occurring in extraterrestrial environments. We focused our study on the characterization of the nature of the interaction between nucleobases and the surface of the minerals magnesium oxide and forsterite by infrared vibrational spectroscopy. We observed that most of the characteristic bands of pure nucleobases vanished when adsorbed on magnesium oxide. On the contrary, in the case of adenine and uracil adsorbed on forsterite, very intense nucleobase absorption peaks appeared. This phenomenon pertains to the surface selection rules changes related to molecular orientation. Moreover, based on the vibrational shifts, we deduced the molecular interaction sites with the mineral surfaces. Furthermore, we investigated the photostability of nucleobases adsorbed on such minerals

  11. Selection of the surface water treatment technology - a full-scale technological investigation.

    Science.gov (United States)

    Pruss, Alina

    2015-01-01

    A technological investigation was carried out over a period of 2 years to evaluate surface water treatment technology. The study was performed in Poland, in three stages. From November 2011 to July 2012, for the first stage, flow tests with a capacity of 0.1-1.5 m³/h were performed simultaneously in three types of technical installations differing by coagulation modules. The outcome of the first stage was the choice of the technology for further investigation. The second stage was performed between September 2012 and March 2013 on a full-scale water treatment plant. Three large technical installations, operated in parallel, were analysed: coagulation with sludge flotation, micro-sand ballasted coagulation with sedimentation, coagulation with sedimentation and sludge recirculation. The capacity of the installations ranged from 10 to 40 m³/h. The third stage was also performed in a full-scale water treatment plant and was aimed at optimising the selected technology. This article presents the results of the second stage of the full-scale investigation. The critical treatment process, for the analysed water, was the coagulation in an acidic environment (6.5 < pH < 7.0) carried out in a system with rapid mixing, a flocculation chamber, preliminary separation of coagulation products, and removal of residual suspended solids through filtration.

  12. Estimating radiological background using imaging spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bernacki, Bruce E.; Schweppe, John E.; Stave, Sean C.; Jordan, David V.; Kulisek, Jonathan A.; Stewart, Trevor N.; Seifert, Carolyn E.

    2014-06-13

    Optical imaging spectroscopy is investigated as a method to estimate radiological background by spectral identification of soils, sediments, rocks, minerals and building materials derived from natural materials and assigning tabulated radiological emission values to these materials. Radiological airborne surveys are undertaken by local, state and federal agencies to identify the presence of radiological materials out of regulatory compliance. Detection performance in such surveys is determined by (among other factors) the uncertainty in the radiation background; increased knowledge of the expected radiation background will improve the ability to detect low-activity radiological materials. Radiological background due to naturally occurring radiological materials (NORM) can be estimated by reference to previous survey results, use of global 40K, 238U, and 232Th (KUT) values, reference to existing USGS radiation background maps, or by a moving average of the data as it is acquired. Each of these methods has its drawbacks: previous survey results may not include recent changes, the global average provides only a zero-order estimate, the USGS background radiation map resolutions are coarse and are accurate only to 1 km – 25 km sampling intervals depending on locale, and a moving average may essentially low pass filter the data to obscure small changes in radiation counts. Imaging spectroscopy from airborne or spaceborne platforms can offer higher resolution identification of materials and background, as well as provide imaging context information. AVIRIS hyperspectral image data is analyzed using commercial exploitation software to determine the usefulness of imaging spectroscopy to identify qualitative radiological background emissions when compared to airborne radiological survey data.

  13. Investigation of the electron emission properties of silver: From exposed to ambient atmosphere Ag surface to ion-cleaned Ag surface

    Energy Technology Data Exchange (ETDEWEB)

    Gineste, T., E-mail: Thomas.Gineste@onera.fr [ONERA The French Aerospace Lab, 31055 Toulouse (France); Belhaj, M. [ONERA The French Aerospace Lab, 31055 Toulouse (France); Teyssedre, G. [LAPLACE - Laboratoire Plasma et Conversion d’Energie -UMR 5213, Université Paul Sabatier - 118, route de Narbonne, 31062 Toulouse Cedex (France); Puech, J. [CNES, 18 Avenue Edouard Belin 31055 Toulouse Cédex 9 (France)

    2015-12-30

    Highlights: • We investigated the electron emission yield of an air exposed Ag to a cleaned Ag. • Air exposed Ag sample was cleaned by ion Ar etching. • Surface composition was determined by AES. • Electron emission yield was related to surface composition evolution. • Natural contamination hugely influence electron properties of Ag sample. - Abstract: Electron emission properties of materials are highly dependent to the surface and the first nanometres subsurface. Technical materials, i.e. used within applications are ordinarily exposed to atmosphere, which interacts with the surface. The contamination layer building up at the surface of materials and/or oxidation layer affects dramatically the electron emission proprieties. In this paper, starting from 99.99% pure silver sample, exposed 4 years to ambient atmosphere, we monitored the variations of the electron emission properties and the surface composition during step by step ion etching procedure.

  14. 324 Building Baseline Radiological Characterization

    International Nuclear Information System (INIS)

    Reeder, R.J.; Cooper, J.C.

    2010-01-01

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building. A total of 85 technical (100 square centimeter (cm 2 )) smears were collected from the Room 147 hoods, the Shielded Materials Facility (SMF), and the Radiochemical Engineering Cells (REC). Exposure rate readings (window open and window closed) were taken at a distance of 2.5 centimeters (cm) and 30 cm from the surface of each smear. Gross beta-gamma and alpha counts of each smear were also performed. The smear samples were analyzed by gamma energy analysis (GEA). Alpha energy analysis (AEA) and strontium-90 analysis were also performed on selected smears. GEA results for one or more samples reported the presence of manganese-54, cobalt-60, silver-108m antimony-125, cesium-134, cesium-137, europium-154, europium-155, and americium-241. AEA results reported the presence of plutonium-239/240, plutonium-238/ 241 Am, curium-243/244, curium-242, and americium-243. Tables 5 through 9 present a summary by location of the estimated maximum removable and total contamination levels in the Room 147 hoods, the SMF, and the REC. The smear sample survey data and laboratory analytical results are presented in tabular form by sample in Appendix A. The Appendix A tables combine survey data documented in radiological survey reports found in Appendix B and laboratory analytical results reported in the 324 Building Physical and Radiological Characterization Study (Berk, Hill, and Landsman 1998), supplemented by the laboratory analytical results found in Appendix C.

  15. An investigation of fungal contamination on the surface of medicinal herbs in China.

    Science.gov (United States)

    Zheng, Run-Sheng; Wang, Wen-Li; Tan, Jing; Xu, Hui; Zhan, Ruo-Ting; Chen, Wei-Wen

    2017-01-01

    The dried parts of medicinal herbs are susceptible to the infection of fungi during pre- or post-harvest procedure. This study aimed to investigate the presence of fungi and their metabolites mycotoxins on the surface of medicinal herbs collected from China. Forty-five retail samples of 15 different medicinal herbs were collected from 3 different regions in China. Then the potential fungi were immediately washed off from the surface of each sample with 0.1% Tween-20 followed by incubation of the rinse on petri-dish with potato dextrose agar containing chloramphenicol at 28 °C. The obtained fungi were isolated as single colonies and then characterized by morphology and molecular identification using internal transcribed spacer (ITS) sequencing with extracted DNA. Meanwhile, the mycotoxin-producing potential of the isolates was studied by liquid chromatography-tandem mass spectrometry (LC-MS/MS). A total of 126 fungi were identified from the surface of samples by morphology and ITS sequencing, with Aspergillus and Penicillium genera as the predominant contaminants. The mycotoxin-producing potential analysis showed that 6 of 8 A. versicolor isolates could produce sterigmatocystin. All 3 A. aculeatus isolates produced ochratoxin A, but only 1 of 3 A. flavus strains produced aflatoxins B 1 and B 2 without G 1 and G 2 . Although the sample contamination ratios were high (≥95.6%), there was no significant difference ( χ 2  = 1.05, P  = 1.0) among the samples from 3 regions, which demonstrates the prevalent fungal contamination in the herbal medicines. The prevalent contamination phenomenon of fungi and high potential risk of sterigmatocystin and ochratoxin A were observed in 45 medicinal herbs collected from China.

  16. Experimental investigation of the microscale rotor-stator cavity flow with rotating superhydrophobic surface

    Science.gov (United States)

    Wang, Chunze; Tang, Fei; Li, Qi; Wang, Xiaohao

    2018-03-01

    The flow characteristics of microscale rotor-stator cavity flow and the drag reduction mechanism of the superhydrophobic surface with high shearing stress were investigated. A microscale rotating flow testing system was established based on micro particle image velocimetry (micro-PIV), and the flow distribution under different Reynolds numbers (7.02 × 103 ≤ Re ≤ 3.51 × 104) and cavity aspect ratios (0.013 ≤ G ≤ 0.04) was measured. Experiments show that, for circumferential velocity, the flow field distributes linearly in rotating Couette flow in the case of low Reynolds number along the z-axis, while the boundary layer separates and forms Batchelor flow as the Reynolds number increases. The separation of the boundary layer is accelerated with the increase of cavity aspect ratio. The radial velocities distribute in an S-shape along the z-axis. As the Reynolds number and cavity aspect ratio increase, the maximum value of radial velocity increases, but the extremum position at rotating boundary remains at Z* = 0.85 with no obvious change, while the extremum position at the stationary boundary changes along the z-axis. The model for the generation of flow disturbance and the transmission process from the stationary to the rotating boundary was given by perturbation analysis. Under the action of superhydrophobic surface, velocity slip occurs near the rotating boundary and the shearing stress reduces, which leads to a maximum drag reduction over 51.4%. The contours of vortex swirling strength suggest that the superhydrophobic surface can suppress the vortex swirling strength and repel the vortex structures, resulting in the decrease of shearing Reynolds stress and then drag reduction.

  17. Investigation of the radiological safety concerns and medical history of the late Joseph T. Harding, former employee of the Paducah Gaseous Diffusion Plant

    Energy Technology Data Exchange (ETDEWEB)

    Vallario, E.J.; Wolfe, H.R.

    1981-03-01

    An ex-employee's claims that inadequate enforcement of radiation safety regulations allowed excess radiation exposure thereby causing his deteriorating health was not substantiated by a thorough investigation.

  18. Contributions of gas-phase plasma chemistry to surface modifications and gas-surface interactions: investigations of fluorocarbon rf plasmas

    Science.gov (United States)

    Cuddy, Michael F., II

    The fundamental aspects of inductively coupled fluorocarbon (FC) plasma chemistry were examined, with special emphasis on the contributions of gas-phase species to surface modifications. Characterization of the gas-phase constituents of single-source CF4-, C2F6-, C3F 8-, and C3F6-based plasmas was performed using spectroscopic and mass spectrometric techniques. The effects of varying plasma parameters, including applied rf power (P) and system pressure (p) were examined. Optical emission spectroscopy (OES) and laser-induced fluorescence (LIF) spectroscopy were employed to monitor the behavior of excited and ground CFx (x = 1,2) radicals, respectively. Mass spectrometric techniques, including ion energy analyses, elucidated behaviors of nascent ions in the FC plasmas. These gas-phase data were correlated with the net effect of substrate processing for Si and ZrO2 surfaces. Surface-specific analyses were performed for post-processed substrates via x-ray photoelectron spectroscopy (XPS) and contact angle goniometry. Generally, precursors with lower F/C ratios tended to deposit robust FC films of high surface energy. Precursors of higher F/C ratio, such as CF4, were associated with etching or removal of material from surfaces. Nonetheless, a net balance between deposition of FC moieties and etching of material exists for each plasma system. The imaging of radicals interacting with surfaces (IRIS) technique provided insight into the phenomena occurring at the interface of the plasma gas-phase and substrate of interest. IRIS results demonstrate that CFx radicals scatter copiously, with surface scatter coefficients, S, generally greater than unity under most experimental conditions. Such considerable S values imply surface-mediated production of the CFx radicals at FC-passivated sites. It is inferred that the primary route to surface production of CFx arises from energetic ion bombardment and ablation of surface FC films. Other factors which may influence the observed CFx

  19. A laboratory investigation of mixing dynamics between biofuels and surface waters

    Science.gov (United States)

    Wang, Xiaoxiang; Cotel, Aline

    2017-11-01

    Recently, production and usage of ethanol-blend fuels or biofuels have increased dramatically along with increasing risk of spilling into surface waters. Lack of understanding of the environmental impacts and absence of standard clean-up procedures make it crucial to study the mixing behavior between biofuels and water. Biofuels are represented by a solution of ethanol and glycol. A Plexiglas tank in conjunction with a wave generator is used to simulate the mixing of surface waters and biofuels under different natural conditions. In our previous experiments, two distinct mixing regimes were observed. One regime was driven by turbulence and the other by interfacial instabilities. However, under more realistic situations, without wind driven waves, only the first mixing regime was found. After one minute of rapid turbulent mixing, biofuels and water were fully mixed and no interface was formed. During the mixing process, chemical reactions happened simultaneously and influenced mixing dynamics. Current experiments are investigating the effect of waves on the mixing dynamics. Support from NSF CBET 1335878.

  20. Investigations into the Degradation of PTFE Surface Properties by Accelerated Aging Tests

    Directory of Open Access Journals (Sweden)

    C. Fragassa

    2016-06-01

    Full Text Available This paper describes an accelerate aging procedure used for investigating the surface alteration of PTFE gaskets commercialized by two alternative producers. These gaskets are installed in modern process plants where tires moulds are cleaned inside a multistage ultrasonic process. The surface of gaskets degrades inexplicably under ordinary operative conditions after a relatively short period. Even if these gaskets are exposed to a combination of ultrasonic waves, temperature, humidity and acid attack, the PTFE properties of resistance nominally exclude the possibility of severe erosion phenomena as highlighted during the real utilization. A possible explanation could be represented by the presence of unexpected chemical compounds emerging from the disaggregation of highly reacting elements from the tire composition. In particular, it is believed that the unpredicted combination of fluorides and chlorides could explain the violent chemical attack highlighted on steel tanks and on their gaskets. But no evidence exists. Thus, the experimental characterization of PTFE properties has to follow an appropriate accelerated aging, aiming at actuating the specific mechanics of wearing as in industrial use.

  1. Investigation into Mass Loading Sensitivity of Sezawa Wave Mode-Based Surface Acoustic Wave Sensors

    Directory of Open Access Journals (Sweden)

    N. Ramakrishnan

    2013-02-01

    Full Text Available In this work mass loading sensitivity of a Sezawa wave mode based surface acoustic wave (SAW device is investigated through finite element method (FEM simulation and the prospects of these devices to function as highly sensitive SAW sensors is reported. A ZnO/Si layered SAW resonator is considered for the simulation study. Initially the occurrence of Sezawa wave mode and displacement amplitude of the Rayleigh and Sezawa wave mode is studied for lower ZnO film thickness. Further, a thin film made of an arbitrary material is coated over the ZnO surface and the resonance frequency shift caused by mass loading of the film is estimated. It was observed that Sezawa wave mode shows significant sensitivity to change in mass loading and has higher sensitivity (eight times higher than Rayleigh wave mode for the same device configuration. Further, the mass loading sensitivity was observed to be greater for a low ZnO film thickness to wavelength ratio. Accordingly, highly sensitive SAW sensors can be developed by coating a sensing medium over a layered SAW device and operating at Sezawa mode resonance frequency. The sensitivity can be increased by tuning the ZnO film thickness to wavelength ratio.

  2. Interfacial surface investigation of super-critical water gasification of corn cob

    Directory of Open Access Journals (Sweden)

    Jin Hui

    2016-01-01

    Full Text Available Super-critical water gasification of biomass is a promising technology for hydrogen production. In order to achieve high hydrogen yield and complete gasification, the operating parameters were investigated and the solid residual was analyzed to study the reaction bottleneck by Fourier transform infrared spectroscopy and scanning electron microscopy. The experimental results showed that most organic functional groups in corn cob were consumed by super-critical water above 500°C, however, the aromatic substance and cyclic ketone were remained. The K2CO3 has the best catalytic effect due to the formation of pore structure in the residual particle surface. The carbon gasification efficiency of 97.97% and the hydrogen yield was 50.28 mol/kg.

  3. Tribological properties investigation of the thermoplastic elastomers surface with the AFM lateral forces mode

    Science.gov (United States)

    Kuznetsova, T. A.; Zubar, T. I.; Lapitskaya, V. A.; Sudzilouskaya, K. A.; Chizhik, S. A.; Didenko, A. L.; Svetlichnyi, V. M.; Vylegzhanina, M. E.; Kudryavtsev, V. V.; Sukhanova, T. E.

    2017-10-01

    The series of new thermoplastic elastomer films based on copoly(urethane-imide)s (coPUI)s and nanocomposites containing from 1 to 10 wt. % carbon nanofillers of different morphology (single-walled carbon nanotubes, carbon nanofibers, and graphene) as well as WS2 and WSe2 nanoparticles, were prepared and investigated by atomic force microscopy in contact mode. The friction coefficient (Cfr) on the films surfaces under conditions of true slip was determined both in one scan field and with multiple scans (200-400) in one place. The measurements were carried out at room temperature and at a heating up to 120°C. It is shown that at heating up to 75-85°C, the friction coefficient of some coPUI decreases significantly. The same effect can be achieved also after 100 scans during multi-scan testing at 20°C.

  4. The Shrinkage Behavior and Surface Topographical Investigation for Micro Metal Injection Molding

    DEFF Research Database (Denmark)

    Islam, Aminul; Giannekas, Nikolaos; Marhöfer, David Maximilian

    2014-01-01

    Metal injection molding (MIM) is a near net shape manufacturing technology that can produce highly complex and dimensionally stable parts for high end engineering applications. Despite the recent growth and industrial interest, micro metal molding is yet to be the field of extensive research...... especially when it is compared with micro molding of thermoplastics. The current paper presents a thorough investigation on the process of metal injection molding where it systematically characterizes the effects of important process conditions on the shrinkage and surface quality of molded parts with micro...... features. Effects of geometrical factors like feature dimensions and distance from the gate on the replication quality are studied. The influence of process conditions on the achievable roughness for the final metal parts is discussed based on the experimental findings. The test geometry is characterized...

  5. Investigation on a TEA-CO II laser with surface corona pre-ionization

    Science.gov (United States)

    Behjat, A.; Aram, M.; Soltanmoradi, F.; Shabanzadeh, M.

    2006-05-01

    The construction of a surface corona UV pre-ionized TEA CO II laser is described and dependence of its average output energy of the laser to gas mixture, discharge voltage and repetition rate is investigated. The electric circuit diagram and geometry of the pre-ionization system are presented. Configuration of circuit has been designed to produce only impulsive voltage difference between the laser electrodes. Also, the triggering configuration of trigatron is prepared for fast operation to minimize the arc occurrence as much as possible. Some data of current, voltage, laser pulses and average output energy versus gas mixture and applied voltages are given. IR spectrometer is used for measurements of central output wavelength of the laser. Operation of the laser on two adjacent vibrational-rotational transitions of CO II molecule has been observed that shows the ability of this laser for working on multi-line in a same time for special applications.

  6. Development of scanning electrochemical microscopy for the investigation of photocatalysis at semiconductor surfaces

    CERN Document Server

    Fonseca, S M M C D

    2002-01-01

    This thesis is concerned with the development and application of scanning electrochemical microscopy (SECM) to investigate interfacial photoelectrochemical processes occurring at supported TiO sub 2 surfaces. The new SECM approach, involving both amperometric and potentiometric electrodes, was used to monitor interfacial photoprocesses with high spatial resolution. A new in situ photoelectrochemical approach to chemical actinometry has been developed and used to determine the light flux through a quartz fibre employed in the SECM system. In this system an ultramicroelectrode (UME) probe is positioned with high precision at a known distance close to a TiO sub 2 -coated fibre and used to detect reactants or products of the ongoing photodegradation process. The microelectrochemical actinometry approach was developed using the well-known liquid phase potassium ferrioxalate actinometer. The approach involved recording the steady-state current for Fe(lll) reduction at an SECM tip positioned close to the fibre. A st...

  7. Laenderyggens degeneration og radiologi

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Gosvig, Kasper Kjaerulf; Sonne-Holm, Stig

    2006-01-01

    and significant relationships between radiological findings and subjective symptoms have both been notoriously difficult to identify. The lack of consensus on clinical criteria and radiological definitions has hampered the undertaking of properly executed epidemiological studies. The natural history of LBP......Low back pain (LBP) is one of the most common conditions, and at the same time one of the most complex nosological entities. The lifetime prevalence is approximately 80%, and radiological features of lumbar degeneration are almost universal in adults. The individual risk factors for LBP...

  8. Marketing a Radiology Practice.

    Science.gov (United States)

    Levin, David C; Rao, Vijay M; Flanders, Adam E; Sundaram, Baskaran; Colarossi, Margaret

    2016-10-01

    In addition to being a profession, the practice of radiology is a business, and marketing is an important part of that business. There are many facets to marketing a radiology practice. The authors present a number of ideas on how to go about doing this. Some marketing methods can be directed to both patients and referring physicians. Others should be directed just to patients, while still others should be directed just to referring physicians. Aside from marketing, many of them provide value to both target audiences. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  9. Referral expectations of radiology

    International Nuclear Information System (INIS)

    Smith, W.L.; Altmaier, E.; Berberoglu, L.; Morris, K.

    1989-01-01

    The expectation of the referring physician are key to developing a successful practice in radiology. Structured interviews with 17 clinicians in both community care and academic practice documented that accuracy of the radiologic report was the single most important factor in clinician satisfaction. Data intercorrelation showed that accuracy of report correlated with frequency of referral (r = .49). Overall satisfaction of the referring physician with radiology correlated with accuracy (r = .69), patient satisfaction (r = .36), and efficiency in archiving (r = .42). These data may be weighted by departmental managers to allocate resources for improving referring physician satisfaction

  10. Investigation of some cleaning surface treatments for the fabrication of ITER first wall panels by HIP

    International Nuclear Information System (INIS)

    Frayssines, P.E.; Bucci, P.; Vito, E. de; Lorenzetto, P.

    2007-01-01

    Full text of publication follows: ITER First Wall (FW) panels are the innermost part of the ITER reactor. Metallic materials used for their manufacture are 316L(N)-IG stainless steel, a copper alloy and beryllium. Stainless steel material is a support structure for the copper alloy that serves as a heat sink material and also for the beryllium tiles that are a protective armour against the plasma. All these materials are bonded together by Hot Isostatic Pressing (HIP). Thus, several types of joints (Cu/Cu, Cu/SS, SS/SS or Cu/Be) are present in a FW panels. Their manufacturing requires a very strict and advanced metallic surface preparation in order to eliminate most of the organic or oxide layers that could prevent the diffusion process between the facing materials. In this field, our laboratory practice enables to obtain sufficiently clean metallic surfaces and high strength joints are obtained when small mockups are made. However, the manufacture of a large number of FW panels in the future requires to find a new cleaning process that is industrially relevant without a strong reduction of the joint's mechanical properties. In this paper we present our investigations to find an industrial solution to clean efficiently copper alloy and stainless steel materials in order to manufacture high strength Cu/Cu, SS/SS or Cu/SS joints. Products investigated are mainly acid liquids proposed by chemical Company and a more advanced technique that uses a plasma process. HIP joints are tested mechanically by making impact toughness and tensile measurements. Results obtained with these solutions are compared to those obtained in our Laboratory by using our own cleaning route. Moreover, XPS analyses are performed on small specimens that have been submitted to the same cleaning treatments in order to better understand the mechanical results of our specimens. (authors)

  11. Investigation of some cleaning surface treatments for the fabrication of ITER first wall panels by HIP

    Energy Technology Data Exchange (ETDEWEB)

    Frayssines, P.E.; Bucci, P. [CEA Grenoble (DRT/LITEN/DTH), 38 (France); Vito, E. de [CEA Grenoble (LITEN/DTH/LCPEM), 38 (France); Lorenzetto, P. [2EFDA, Garching (Germany)

    2007-07-01

    Full text of publication follows: ITER First Wall (FW) panels are the innermost part of the ITER reactor. Metallic materials used for their manufacture are 316L(N)-IG stainless steel, a copper alloy and beryllium. Stainless steel material is a support structure for the copper alloy that serves as a heat sink material and also for the beryllium tiles that are a protective armour against the plasma. All these materials are bonded together by Hot Isostatic Pressing (HIP). Thus, several types of joints (Cu/Cu, Cu/SS, SS/SS or Cu/Be) are present in a FW panels. Their manufacturing requires a very strict and advanced metallic surface preparation in order to eliminate most of the organic or oxide layers that could prevent the diffusion process between the facing materials. In this field, our laboratory practice enables to obtain sufficiently clean metallic surfaces and high strength joints are obtained when small mockups are made. However, the manufacture of a large number of FW panels in the future requires to find a new cleaning process that is industrially relevant without a strong reduction of the joint's mechanical properties. In this paper we present our investigations to find an industrial solution to clean efficiently copper alloy and stainless steel materials in order to manufacture high strength Cu/Cu, SS/SS or Cu/SS joints. Products investigated are mainly acid liquids proposed by chemical Company and a more advanced technique that uses a plasma process. HIP joints are tested mechanically by making impact toughness and tensile measurements. Results obtained with these solutions are compared to those obtained in our Laboratory by using our own cleaning route. Moreover, XPS analyses are performed on small specimens that have been submitted to the same cleaning treatments in order to better understand the mechanical results of our specimens. (authors)

  12. Aerial vehicle with paint for detection of radiological and chemical warfare agents

    Science.gov (United States)

    Farmer, Joseph C.; Brunk, James L.; Day, S. Daniel

    2013-04-02

    A paint that warns of radiological or chemical substances comprising a paint operatively connected to the surface, an indicator material carried by the paint that provides an indication of the radiological or chemical substances, and a thermo-activation material carried by the paint. In one embodiment, a method of warning of radiological or chemical substances comprising the steps of painting a surface with an indicator material, and monitoring the surface for indications of the radiological or chemical substances. In another embodiment, a paint is operatively connected to a vehicle and an indicator material is carried by the paint that provides an indication of the radiological or chemical substances.

  13. Remote sensing and geochemical investigations of selected surface processes in Egypt and Missouri

    Science.gov (United States)

    Crombie, Mary Katherine

    This thesis consists of three studies of surface processes on Earth: 1. Age and isotopic constraints of pluvial episodes in the Western Desert of Egypt. North Africa has undergone drastic climatic change over the past several hundred thousand years. Timing of humid intervals called pluvials was investigated by uranium- series disequilibrium dating of travertines from the Kurkur Oasis, Western Desert, Egypt. Stable oxygen isotopes of the travertines were used in equilibrium oxygen isotope fractionation calculations indicating the Kurkur travertines have δ18O values similar to ancient Western Desert groundwaters (~[- ]11/perthous). The ages of the of the travertines correspond to times of monsoonal maxima, eustatic sea level high stands and interglacial maxima. Increased precipitation, recharge of Western Desert groundwaters, and resultant travertine deposition are interpreted to be consequences of Milankovitch cycle forcing, through enhanced Atlantic and Indian Ocean monsoons during periods of enhanced northern summer insolation. 2. Identification of soil moisture as an environmental risk factor for filariasis in Egypt. Bancroftian filariasis is a deforming illness transmitted by mosquitoes (Culex. pipiens) and caused by the parasite Wuchereria bancrofti (WHO technical report 821; Neva and Brown, 1994). Environmental variables, such as humidity, play an important role in the transmission cycle of filariasis. Landsat Thematic Mapper data were used to model the surface soil moisture conditions of the southern Nile Delta region of Egypt as a proxy for environmental humidity. Filariasis infection rates were found to be negligible for areas with low surface soil moisture availability (>20%). Variable infection rates were observed for regions with higher surface soil moisture content, possibly due to anthropogenic influences such as insect control and the use of anti- filarial drugs. 3. Monitoring of Pb aerosol fallout in the vicinity of the Glover smelter, Southeastern

  14. Structure investigation of organic molecules on Au(111) surfaces; Strukturuntersuchung organischer Molekuele auf Au(111)-Oberflaechen

    Energy Technology Data Exchange (ETDEWEB)

    Kazempoor, Michel

    2009-02-02

    The present work covers two topics namely the coadsorption of formic acid and water on Au(111) and the structure of biphenylalkanthiole SAMs on Au(111) surfaces. The coadsorption of formic acid and water on Au(111) surfaces has been investigated by means of vibrational and photoelectron spectroscopy (HREELS, XPS). Formic acid adsorbs at 90 K molecularly with vibrational modes characteristic for flat lying zig-zag chains in the mono- and multilayer regime, like in solid formic acid. The structure of the flat lying formic acid chains was determined by low energy electron diffraction (LEED) as a (2r3 x r19) unit cell. Annealing results in a complete desorption at 190 K. Sequential adsorption of formic acid and water at 90 K shows no significant chemical interaction. Upon annealing the coadsorbed layer to 140 K a hydrogenbonded cyclic complex of formic acid with one water molecule could be identified using isotopically labelled adsorbates. Upon further annealing this complex decomposes leaving molecularly adsorbed formic acid on the surface at 160 K, accompanied by a proton exchange between formic acid and water. The influence of the alkane spacer chain length on the structure of biphenylalkanethiols on Au(111) surfaces was investigated as well. A systematic study was done on BPn-SAMs deposited from the gas phase. For every chain length a structure was found by LEED. Furthermore the influence of temperature on the structure was investigated in the range from room temperature up to about 400 K. To obviate influences from different preparation methods BP3 and BP4 was deposited from gas phase and from solution. No LEED spots were observed on BP4 SAMs deposited from solution. For BP3 an influence of the preparation could be excluded. For all BPn-SAMs a good agreement between LEED and STM data's was found. Nevertheless different unit cells were determined by LEED and STM consistent structures could be suggested considering the unit cell size given by LEED and the

  15. Pediatric radiology for medical-technical radiology assistants/radiologists

    International Nuclear Information System (INIS)

    Oppelt, Birgit

    2010-01-01

    The book on pediatric radiology includes the following chapter: differences between adults and children; psycho-social aspects concerning the patient child in radiology; relevant radiation doses in radiology; help for self-help: simple phantoms for image quality estimation in pediatric radiology; general information; immobilization of the patient; pediatric features for radiological settings; traumatology; contrast agents; biomedical radiography; computerized tomography; NMR imaging; diagnostic ultrasonography; handling of stress practical recommendations; medical displays.

  16. Investigation on the effect of collagen and vitamins on biomimetic hydroxyapatite coating formation on titanium surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Ciobanu, Gabriela, E-mail: gciobanu03@yahoo.co.uk [“Gheorghe Asachi” Technical University of Iasi, Faculty of Chemical Engineering and Environmental Protection, Prof. dr. docent Dimitrie Mangeron Rd., no. 63, zip: 700050, Iasi (Romania); Ciobanu, Octavian [“Grigore T. Popa” University of Medicine and Pharmacy, Faculty of Medical Bioengineering, Universitatii Str., no. 16, zip: 700115, Iasi (Romania)

    2013-04-01

    This study uses an in vitro experimental approach to investigate the roles of collagen and vitamins in regulating the deposition of hydroxyapatite layer on the pure titanium surface. Titanium implants were coated with a hydroxyapatite layer under biomimetic conditions by using a supersaturated calcification solution (SCS), modified by adding vitamins A and D{sub 3}, and collagen. The hydroxyapatite deposits on titanium were investigated by means of scanning electron microscopy (SEM) coupled with X-ray analysis (EDX), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD) and Fourier transformed infrared (FTIR) spectroscopy. The results obtained have shown that hydroxyapatite coatings were produced in vitro under vitamins and collagen influence. - Highlights: ► Hydroxyapatite was grown on Ti using a modified supersaturated calcification solution (M-SCS). ► Vitamins (A and D3) and collagen in M-SCS have a significant effect on apatite precipitation. ► M-SCS stimulates a biomimetic apatite deposition with 0.5–1 μm thickness in a short time. ► Hydroxyapatite crystallites have thin plate morphologies and size below 1 μm.

  17. Investigation on the effect of collagen and vitamins on biomimetic hydroxyapatite coating formation on titanium surfaces

    International Nuclear Information System (INIS)

    Ciobanu, Gabriela; Ciobanu, Octavian

    2013-01-01

    This study uses an in vitro experimental approach to investigate the roles of collagen and vitamins in regulating the deposition of hydroxyapatite layer on the pure titanium surface. Titanium implants were coated with a hydroxyapatite layer under biomimetic conditions by using a supersaturated calcification solution (SCS), modified by adding vitamins A and D 3 , and collagen. The hydroxyapatite deposits on titanium were investigated by means of scanning electron microscopy (SEM) coupled with X-ray analysis (EDX), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD) and Fourier transformed infrared (FTIR) spectroscopy. The results obtained have shown that hydroxyapatite coatings were produced in vitro under vitamins and collagen influence. - Highlights: ► Hydroxyapatite was grown on Ti using a modified supersaturated calcification solution (M-SCS). ► Vitamins (A and D3) and collagen in M-SCS have a significant effect on apatite precipitation. ► M-SCS stimulates a biomimetic apatite deposition with 0.5–1 μm thickness in a short time. ► Hydroxyapatite crystallites have thin plate morphologies and size below 1 μm

  18. Numerical investigation of the tribological performance of micro-dimple textured surfaces under hydrodynamic lubrication.

    Science.gov (United States)

    Li, Kangmei; Jing, Dalei; Hu, Jun; Ding, Xiaohong; Yao, Zhenqiang

    2017-01-01

    Surface texturing is an important approach for controlling the tribological behavior of friction pairs used in mechanical and biological engineering. In this study, by utilizing the method of three-dimensional computational fluid dynamics (CFD) simulation, the lubrication model of a friction pair with micro-dimple array was established based on the Navier-Stokes equations. The typical pressure distribution of the lubricant film was analyzed. It was found that a positive hydrodynamic pressure is generated in the convergent part of the micro-dimple, while a negative hydrodynamic pressure is generated in the divergent part. With suitable parameters, the total integration of the pressure is positive, which can increase the load-carrying capacity of a friction pair. The effects of the micro-dimple parameters as well as fluid properties on tribological performance were investigated. It was concluded that under the condition of hydrodynamic lubrication, the main mechanism for the improvement in the tribological performance is the combined effects of wedging and recirculation. Within the range of parameters investigated in this study, the optimum texture density is 13%, while the optimum aspect ratio varies with the Reynolds number. For a given Reynolds number, there exists a combination of texture density and aspect ratio at which the optimum tribological performance could be obtained. Conclusions from this study could be helpful for the design of texture parameters in mechanical friction components and even in artificial joints.

  19. Investigation of the effect of cutting speed on the Surface Roughness parameters in CNC End Milling using Artificial Neural Network

    International Nuclear Information System (INIS)

    Al Hazza, Muataz H F; Adesta, Erry Y T

    2013-01-01

    This research presents the effect of high cutting speed on the surface roughness in the end milling process by using the Artificial Neural Network (ANN). An experimental investigation was conducted to measure the surface roughness for end milling. A set of sparse experimental data for finish end milling on AISI H13 at hardness of 48 HRC have been conducted. The artificial neural network (ANN) was applied to simulate and study the effect of high cutting speed on the surface roughness

  20. Laenderyggens degeneration og radiologi

    DEFF Research Database (Denmark)

    Jacobsen, Steffen; Gosvig, Kasper Kjaerulf; Sonne-Holm, Stig

    2006-01-01

    Low back pain (LBP) is one of the most common conditions, and at the same time one of the most complex nosological entities. The lifetime prevalence is approximately 80%, and radiological features of lumbar degeneration are almost universal in adults. The individual risk factors for LBP and signi......Low back pain (LBP) is one of the most common conditions, and at the same time one of the most complex nosological entities. The lifetime prevalence is approximately 80%, and radiological features of lumbar degeneration are almost universal in adults. The individual risk factors for LBP...... and significant relationships between radiological findings and subjective symptoms have both been notoriously difficult to identify. The lack of consensus on clinical criteria and radiological definitions has hampered the undertaking of properly executed epidemiological studies. The natural history of LBP...

  1. SA Journal of Radiology

    African Journals Online (AJOL)

    SA Journal of Radiology. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 9, No 2 (2005) >. Log in or Register to get access to full text downloads.

  2. SA Journal of Radiology

    African Journals Online (AJOL)

    SA Journal of Radiology. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 17, No 1 (2013) >. Log in or Register to get access to full text downloads.

  3. American College of Radiology

    Science.gov (United States)

    ... 2017 Meeting & Course Calendar Where ACR Exhibits ACR Data Science Institute Structures AI Advances DSI framework to help ... Announcements Upcoming Meetings 11/16/2017 The ACR Data Science Institute™ Structures Artificial Intelligence Development to Optimize Radiology ...

  4. Radiology Architecture Project Primer.

    Science.gov (United States)

    Sze, Raymond W; Hogan, Laurie; Teshima, Satoshi; Davidson, Scott

    2017-12-19

    The rapid pace of technologic advancement and increasing expectations for patient- and family-friendly environments make it common for radiology leaders to be involved in imaging remodel and construction projects. Most radiologists and business directors lack formal training in architectural and construction processes but are expected to play significant and often leading roles in all phases of an imaging construction project. Avoidable mistakes can result in significant increased costs and scheduling delays; knowledgeable participation and communication can result in a final product that enhances staff workflow and morale and improves patient care and experience. This article presents practical guidelines for preparing for and leading a new imaging architectural and construction project. We share principles derived from the radiology and nonradiology literature and our own experience over the past decade completely remodeling a large pediatric radiology department and building a full-service outpatient imaging center. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  5. Radiological considerations for decommissioning

    International Nuclear Information System (INIS)

    Adler, J.J.

    1993-01-01

    It has been said, by those uninitiated to decommissioning work, that radiological considerations required for decommissioning are the same as those for an operating facility. In reality, nothing could be further from the truth. The act of decommissioning can be likened to cutting off a tree limb while sitting on it. This paper discusses some of the unique radiological aspects that are associated with implementing a decommissioning health physics program. There are physical constraints that may cause major differences between a normal operational and a decommissioning health physics program. Throughout the decommissioning process, the installed equipment and services that were needed to support an operational program are constantly being removed or may already be disabled due to the age of the facility. Those affecting radiological protection programs typically would include radiation shielding, ventilation systems, breathing air supply for respiratory protection, and radiological monitoring systems

  6. Radiology and the law

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    This book contains 12 chapters. Some of the chapter titles are: The Law of Medical Malpractice: An Overview; The Radiologist as Defendant; The Radiologist as an Expert Witness; The Missed Diagnosis; Legalities of the Radiograph; and Angiography and Interventional Radiology

  7. Radiology capital asset management.

    Science.gov (United States)

    Wagener, G N; Pridlides, A J

    1993-01-01

    Radiology administrators are expected not only to take on the ultimate accountability for meeting the needs and challenges of present day-to-day operations, but also to plan for the future. Computer Aided Facility Management (CAFM), as a tool, enables radiology managers to obtain up-to-date data to manage their services. Using Autocad on a unix-based minicomputer as the graphical base generator and integrating information from a MUMPS-based minicomputer, the CAFM process can define areas to be studied for productivity and life cycle costs. From an analysis of radiology service, management was able to make solid judgement calls for equipment replacement and facility project renovation to effectively manage radiology resources.

  8. Ergonomics in radiology

    Energy Technology Data Exchange (ETDEWEB)

    Goyal, N. [Department of Radiology, University Hospital of Wales, Cardiff (United Kingdom)], E-mail: nimitgoyal@doctors.org.uk; Jain, N.; Rachapalli, V. [Department of Radiology, University Hospital of Wales, Cardiff (United Kingdom)

    2009-02-15

    The use of computers is increasing in every field of medicine, especially radiology. Filmless radiology departments, speech recognition software, electronic request forms and teleradiology are some of the recent developments that have substantially increased the amount of time a radiologist spends in front of a computer monitor. Computers are also needed for searching literature on the internet, communicating via e-mails, and preparing for lectures and presentations. It is well known that regular computer users can suffer musculoskeletal injuries due to repetitive stress. The role of ergonomics in radiology is to ensure that working conditions are optimized in order to avoid injury and fatigue. Adequate workplace ergonomics can go a long way in increasing productivity, efficiency, and job satisfaction. We review the current literature pertaining to the role of ergonomics in modern-day radiology especially with the development of picture archiving and communication systems (PACS) workstations.

  9. Ergonomics in radiology

    International Nuclear Information System (INIS)

    Goyal, N.; Jain, N.; Rachapalli, V.

    2009-01-01

    The use of computers is increasing in every field of medicine, especially radiology. Filmless radiology departments, speech recognition software, electronic request forms and teleradiology are some of the recent developments that have substantially increased the amount of time a radiologist spends in front of a computer monitor. Computers are also needed for searching literature on the internet, communicating via e-mails, and preparing for lectures and presentations. It is well known that regular computer users can suffer musculoskeletal injuries due to repetitive stress. The role of ergonomics in radiology is to ensure that working conditions are optimized in order to avoid injury and fatigue. Adequate workplace ergonomics can go a long way in increasing productivity, efficiency, and job satisfaction. We review the current literature pertaining to the role of ergonomics in modern-day radiology especially with the development of picture archiving and communication systems (PACS) workstations

  10. First-principles investigations of Ni3Al(111) and NiAl(110) surfaces at metal dusting conditions

    DEFF Research Database (Denmark)

    Saadi, Souheil; Hinnemann, Berit; Appel, Charlotte C.

    2011-01-01

    We investigate the structure and surface composition of the γ′-Ni3Al(111) and β-NiAl(110) alloy surfaces at conditions relevant for metal dusting corrosion related to catalytic steam reforming of natural gas. In regular service as protective coatings, nickel–aluminum alloys are protected...

  11. Spray forming: A numerical investigation of the influence of the gas to melt ratio on the billet surface temperature

    DEFF Research Database (Denmark)

    Pryds, Nini; Hattel, Jesper

    2005-01-01

    The relationship between the Gas to Melt Ratio (GMR) and the surface temperature of an evolving billet surface in spray forming is investigated numerically. The basis for the analysis is an integrated approach for modelling the entire spray forming process. This model includes the droplet atomisa...

  12. INVESTIGATION OF POLYMER SURFACES USING SCANNING FORCE MICROSCOPY (SFM) - A NEW DIRECT LOOK ON OLD POLYMER PROBLEMS

    NARCIS (Netherlands)

    GRIM, PCM; BROUWER, HJ; SEYGER, RM; OOSTERGETEL, GT; BERGSMASCHUTTER, WG; ARNBERG, AC; GUTHNER, P; DRANSFELD, K; HADZIIOANNOU, G

    In this contribution, the general concepts of force microscopy will be presented together with its application to polymer surfaces (Ref.1). Several examples will be presented to illustrate that force microscopy is a powerful and promising tool for investigation of (polymer) surfaces, such as the

  13. Radiologic science for technologists

    International Nuclear Information System (INIS)

    Bushong, S.C.

    1988-01-01

    This book provides in-depth coverage of physics, biology and protection for the radiologic technology student. It presents a significant portion of all of the science required of radiologic technology students under one cover. Chapter content reflects a readable and practical organization with outlines listed on the first page of each chapter and sample problems at the end. New to this edition are: new and expanded sections on radiation techniques, digital imaging, and magnetic resonance imaging and ultrasound

  14. Radiological protection act, 1991

    International Nuclear Information System (INIS)

    1991-01-01

    This Act provides for the establishment of the Radiological Protection Institute of Ireland and dissolves An Bord Fuinnimh Nuicleigh (the Board), transferring its assets and liabilities to the Institute. It sets out a range of radiation protection measures to be taken by various Ministers in the event of a radiological emergency and gives effect at national level to the Assistance Convention, the Early Notification Convention and the Physical Protection Convention. The Institute is the competent Irish authority for the three Conventions. (NEA) [fr

  15. Molecular investigation of evaporation of biodroplets containing single-strand DNA on graphene surface.

    Science.gov (United States)

    Akbari, Fahimeh; Foroutan, Masumeh

    2018-02-14

    In this study, the water droplet behaviour of four different types of single-strand DNA with homogeneous base sequence on a graphene substrate during evaporation of the droplet was investigated using molecular dynamics (MD) simulation. The simulation results indicated that the evaporation depended on the DNA sequence. The observed changes can be divided into four parts: (i) vaporization mode, (ii) evaporation flux, (iii) mechanism of single-strand placement on the surface, and (iv) consideration of remaining single strands after evaporation. Our simulation observations indicated different evaporation modes for thymine biodroplets as compared to those for other biodroplets. The evaporation of the thymine biodroplets occurred with an increase in the contact angle, while that of the other biodroplets occur in a constant contact angle mode. Moreover, thymine biodroplets generate the lowest contact line compared to other single strands, and it is always placed far away from the centre of the droplets during evaporation. Investigating variations in the evaporation flux shows that thymine has the highest evaporation flux and guanine has the lowest. Moreover, during initial evaporation, the flux of evaporation increases at the triple point of the biodroplets containing thymine single strands, while it decreases in the other biodroplets. The following observation was obtained from the study of the placement of single strands on the substrate: guanine and thymine interacted slower than other single strands during evaporation with graphene, adenine single strand had a higher folding during evaporation, and guanine single strand showed the lowest end-to-end distance. The investigation of single-strand DNA after evaporation shows that adenine produces the most stable structure at the end of evaporation. In addition, cytosine is the most stretched single-strand DNA due to its lack of internal π-π stacking and hydrogen bonding. Therefore, cytosine single strand is more

  16. Experimental investigations of sensor-based surface following performed by a mobile manipulator

    Energy Technology Data Exchange (ETDEWEB)

    Reister, D.B.; Unseren, M.A.; Baker, J.E.; Pin, F.G.

    1994-10-01

    We discuss a series of surface following experiments using a range finder mounted on the end of an arm that is mounted on a vehicle. The goal is to keep the range finder at a fixed distance from an unknown surface and to keep the orientation of the range finder perpendicular to the surface. During the experiments, the vehicle moves along a predefined trajectory while planning software determines the position and orientation of the arm. To keep the range finder perpendicular to the surface, the planning software calculates the surface normal for the unknown surface. We assume that the unknown surface is a cylinder (the surface depends on x and y but does not depend on z). To calculate the surface normal, the planning software must calculate the locations (x,y) of points on the surface in world coordinates. The calculation requires data on the position and orientation of the vehicle, the position and orientation of the arm, and the distance from the range finder to the surface. We discuss four series of experiments. During the first series of experiments, the calculated surface normal values had large high frequency random variations. A filter was used to produce an average value for the surface normal and we limited the rate of change in the yaw angle target for the arm. We performed the experiment for a variety of concave and convex surfaces. While the experiments were qualitative successes, the measured distance to the surface was significantly different than the target. The distance errors were systematic, low frequency, and had magnitudes up to 25 mm. During the second series of experiments, we reduced the variations in the calculated surface normal values. While reviewing the data collected while following the surface of a barrel, we found that the radius of the calculated surface was significantly different than the measured radius of the barrel.

  17. Campaign of complementary investigation on the old mining site of Saint-Pierre (Cantal) 2. part of the relative expertise at the radiological situation of the site

    International Nuclear Information System (INIS)

    2007-01-01

    The C.L.I. of Saint-Pierre which was held on May 19., 2006 in Mauriac (Cantal) confirmed the program of additional investigations to be collectively led by the I.R.S.N. and the C.R.I.I.R.A.D. on Saint Pierre site. Main directions are the following ones: realize additional analyses on the drainages of water; measure the external exposure on 14 plots of land; measure the flux of radon at the ground level and radon inside houses; realize investigations on the food chain. The present report reports campaigns of sampling realized by the I.R.S.N. in 2006 as well as analyses led in its laboratories. (N.C.)

  18. Diagnostic and interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, Thomas J. [Klinikum der Johann Wolfgang Goethe-Universitaet, Frankfurt am Main (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Reith, Wolfgang [Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany). Klinik fuer Diagnostische und Interventionelle Neuroradiologie; Rummeny, Ernst J. (ed.) [Technische Univ. Muenchen Klinikum rechts der Isar, Muenchen (Germany). Inst. fuer Radiologie

    2016-08-01

    This exceptional book covers all aspects of diagnostic and interventional radiology within one volume, at a level appropriate for the specialist. From the basics through diagnosis to intervention: the reader will find a complete overview of all areas of radiology. The clear, uniform structure, with chapters organized according to organ system, facilitates the rapid retrieval of information. Features include: Presentation of the normal radiological anatomy Classification of the different imaging procedures according to their diagnostic relevance Imaging diagnosis with many reference images Precise description of the interventional options The inclusion of many instructive aids will be of particular value to novices in decision making: Important take home messages and summaries of key radiological findings smooth the path through the jungle of facts Numerous tables on differential diagnosis and typical findings in the most common diseases offer a rapid overview and orientation Diagnostic flow charts outline the sequence of diagnostic evaluation All standard procedures within the field of interventional radiology are presented in a clinically relevant and readily understandable way, with an abundance of illustrations. This is a textbook, atlas, and reference in one: with more than 2500 images for comparison with the reader's own findings. This comprehensive and totally up-to-date book provides a superb overview of everything that the radiology specialist of today needs to know.

  19. Rethinking radiology informatics.

    Science.gov (United States)

    Kohli, Marc; Dreyer, Keith J; Geis, J Raymond

    2015-04-01

    Informatics innovations of the past 30 years have improved radiology quality and efficiency immensely. Radiologists are groundbreaking leaders in clinical information technology (IT), and often radiologists and imaging informaticists created, specified, and implemented these technologies, while also carrying the ongoing burdens of training, maintenance, support, and operation of these IT solutions. Being pioneers of clinical IT had advantages of local radiology control and radiology-centric products and services. As health care businesses become more clinically IT savvy, however, they are standardizing IT products and procedures across the enterprise, resulting in the loss of radiologists' local control and flexibility. Although this inevitable consequence may provide new opportunities in the long run, several questions arise. What will happen to the informatics expertise within the radiology domain? Will radiology's current and future concerns be heard and their needs addressed? What should radiologists do to understand, obtain, and use informatics products to maximize efficiency and provide the most value and quality for patients and the greater health care community? This article will propose some insights and considerations as we rethink radiology informatics.

  20. Theoretical investigation of phase transition on GaAs(0 0 1)-c(4 x 4) surface

    International Nuclear Information System (INIS)

    Ishizaki, Hirotoshi; Akiyama, Toru; Nakamura, Kohji; Shiraishi, Kenji; Taguchi, Akihito; Ito, Tomonori

    2005-01-01

    The surface phase transition between GaAs(0 0 1)-c(4 x 4) and -(2 x 4)β2 surfaces is systematically investigated by using our ab initio-based approach. The phase diagram calculations for the c(4 x 4) surfaces as functions of temperature and As pressure reveal that three kinds of c(4 x 4) surfaces consisting of Ga-As dimers and/or Ga-Ga dimers become stable near the phase transition temperature. The electron counting Monte Carlo simulation and ab initio calculations are also performed to investigate the structural change of the c(4 x 4) surface after predepositing a 0.5 monolayer of Ga on the three kinds of c(4 x 4) surfaces. The calculated results suggest that the c(4 x 4) surfaces consisting of three Ga-As dimers or one Ga-Ga dimer and two Ga-As dimers in the (4 x 4) surface unit cell possibly change their structures to (2 x 4)β2 structures with Ga-As surface dimers. The conventional (2 x 4)β2 surface consisting of As dimers finally appears due to destabilization of Ga-As dimers at high temperature and high pressure

  1. Full Scale Investigation of the Dynamic Heat Storage of Concrete Decks with PCM and Enhanced Heat Transfer Surface Area

    DEFF Research Database (Denmark)

    Pomianowski, Michal Zbigniew; Heiselberg, Per; Jensen, Rasmus Lund

    2013-01-01

    The paper presents the full-scale experimental investigation of the dynamic heat storage potential of the prefabricated hollow core deck elements with and without phase change material (PCM) and with and without increased bottom surface area of the decks. In the presented investigation five types...... material tiles. The experimental investigation presented in the paper is performed in the specially designed modified hot box apparatus that allows maintaining periodic steady-state tests with the full-scale concrete deck elements. The presented research investigates if the extended surface area and PCM...

  2. Investigating Surface and Near-Surface Bushfire Fuel Attributes: A Comparison between Visual Assessments and Image-Based Point Clouds.

    Science.gov (United States)

    Spits, Christine; Wallace, Luke; Reinke, Karin

    2017-04-20

    Visual assessment, following guides such as the Overall Fuel Hazard Assessment Guide (OFHAG), is a common approach for assessing the structure and hazard of varying bushfire fuel layers. Visual assessments can be vulnerable to imprecision due to subjectivity between assessors, while emerging techniques such as image-based point clouds can offer land managers potentially more repeatable descriptions of fuel structure. This study compared the variability of estimates of surface and near-surface fuel attributes generated by eight assessment teams using the OFHAG and Fuels3D, a smartphone method utilising image-based point clouds, within three assessment plots in an Australian lowland forest. Surface fuel hazard scores derived from underpinning attributes were also assessed. Overall, this study found considerable variability between teams on most visually assessed variables, resulting in inconsistent hazard scores. Variability was observed within point cloud estimates but was, however, on average two to eight times less than that seen in visual estimates, indicating greater consistency and repeatability of this method. It is proposed that while variability within the Fuels3D method may be overcome through improved methods and equipment, inconsistencies in the OFHAG are likely due to the inherent subjectivity between assessors, which may be more difficult to overcome. This study demonstrates the capability of the Fuels3D method to efficiently and consistently collect data on fuel hazard and structure, and, as such, this method shows potential for use in fire management practices where accurate and reliable data is essential.

  3. Acid Aging Effects on Surfaces of PTFE Gaskets Investigated by Fourier Transform Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    L. Giorgini

    2016-09-01

    Full Text Available This paper investigates the effect of a prolonged acid and thermal attack, on the surface of PTFE by Fourier Transform Infrared Micro-Spectroscopy (FT-IR. The materials are commercialized by two alternative producers in form of Teflon tapes. These tapes are installed in process plants where tires moulds are cleaned inside a multistage ultrasonic process. In these cases, Teflon tapes, having a role of gaskets, show inexplicably phenomena of degradation in relatively short operation periods. Even considering that these gaskets are exposed to the combined effect of ultrasonic waves, temperature, humidity and acid attack, the PTFE properties of resistance nominally exclude the possibility of these severe erosion phenomena. An interesting explanation can be related to the potential presence in the cleaning solution, mainly based on sulfamic acid, of highly reactive chemical compounds, as chlorides and fluorides, originated by the disaggregation of elements from the tire composition and/or additives used as processing aids and/or by catalytic effect generated by fluorine produced by PTFE degradation. In general, up to 300 different chemical elements, both organic and inorganic, natural and synthetic, are merged in a tire. Since this composition is practically unknown, especially regarding additives and “unusual elements”, representing a secrecy of each tire manufactures, it is really complex to define the chemical composition of the cleaning solution with an appropriate precision. As a consequence, the gaskets have been treated with different mixtures of acids in the way to combine a larger range of possibilities. Thus, the FT-IR experimental characterization of PTFE surface properties followed an appropriate accelerated aging, aiming at actuating the specific mechanics of wearing as in industrial use. The different acid treatments adopted for accelerating the aging of gaskets have highlighted the different behaviour of the PTFE matrix, but

  4. Ultrastructural investigation of root canal dentine surface after application of active ultrasonic method

    Directory of Open Access Journals (Sweden)

    Mitić Aleksandar

    2008-01-01

    Full Text Available INTRODUCTION The basic work principle of all ultrasonic techniques is the piezoelectric effect of producing high frequency ultrasounds of small length, which are transmitted over the endodontic extensions or canal instruments into the root canal. When in contact with the tissue, ultrasonic vibrations are converted into mechanical oscillations. Ultrasonic waves and the obtained oscillations along with the synergic effect of irrigation bring about the elimination of smear layer from the root canal walls. OBJECTIVE The aim of the study was to ultrastucturally examine the effect of smear layer removal from the walls of canals by the application of the active ultrasonic method without irrigation, that is by the application of ultrasound and irrigation using distilled water and 2.5% NaOCl. METHOD The investigation comprised 35 single-canal, extracted human teeth. After removal of the root canal content, experimental samples were divided into three groups. According to the procedure required, the first group was treated by ultrasound without irrigation; the second one by ultrasound with irrigation using distilled water; and the third group was treated by ultrasound and irrigation using 2.5% NaOCl solution. The control samples were treated by machine rotating instruments (Pro-File and were rinsed by distilled water. RESULTS The obtained results showed that the ultrasonic treatment of the root canal without irrigation did not remove the smear layer. The dentine canals are masked, and big dentine particles are scattered on the intertubular dentine. The ultrasonic treatment by using irrigation with distilled water provides cleaner dentine walls and open dentine tubules but with smaller particles on the intertubular dentine. The ultrasound treatment by using irrigation with 2.5% NaOCl solution provides a clean intertubular dentine surface without a smear layer and clearly open dentine tubules. CONCLUSION Instrumentation of the root canal by application of

  5. The shrinkage behavior and surface topographical investigation for micro metal injection molding

    Science.gov (United States)

    Islam, A.; Giannekas, N.; Marhöfer, D. M.; Tosello, G.; Hansen, H. N.

    2015-05-01

    Metal injection molding (MIM) is a near net shape manufacturing technology that can produce highly complex and dimensionally stable parts for high end engineering applications. Despite the recent growth and industrial interest, micro metal molding is yet to be the field of extensive research especially when it is compared with micro molding of thermoplastics. The current paper presents a thorough investigation on the process of metal injection molding where it systematically characterizes the effects of important process conditions on the shrinkage and surface quality of molded parts with micro features. Effects of geometrical factors like feature dimensions and distance from the gate on the replication quality are studied. The influence of process conditions on the achievable roughness for the final metal parts is discussed based on the experimental findings. The test geometry is characterized by 2½D surface structures containing thin ribs of different aspect ratios and thicknesses in the sub-mm dimensional range. The test parts were molded from Catamold 316L with a conventional injection molding machine. Afterwards, the parts were de-binded and sintered to produce the final test samples. Among the different process parameters studied, the melt temperature was the most influential parameters for better replication and dimensional stability of the final part. The results presented in the paper clearly show that the shrinkage in metal part is not uniform in the micro scale. It depends on the feature dimensions and also on the process conditions. A thin section of the part exhibits higher relative shrinkage compared with a thicker section. Based on these findings, it can be concluded that a micro part molded by MIM process will have higher relative shrinkage compared to a macro part made with the same process.

  6. Experimental investigation of thermal conductivity coefficient and heat exchange between fluidized bed and inclined exchange surface

    Directory of Open Access Journals (Sweden)

    B. Stojanovic

    2009-06-01

    Full Text Available The paper presents experimental research of thermal conductivity coefficients of the siliceous sand bed fluidized by air and an experimental investigation of the particle size influence on the heat transfer coefficient between fluidized bed and inclined exchange surfaces. The measurements were performed for the specific fluidization velocity and sand particle diameters d p=0.3, 0.5, 0.9 mm. The industrial use of fluidized beds has been increasing rapidly in the past 20 years owing to their useful characteristics. One of the outstanding characteristics of a fluidized bed is that it tends to maintain a uniform temperature even with nonuniform heat release. On the basis of experimental research, the influence of the process's operational parameters on the obtained values of the bed's thermal conductivity has been analyzed. The results show direct dependence of thermal conductivity on the intensity of mixing, the degree of fluidization, and the size of particles. In the axial direction, the coefficients that have been treated have values a whole order higher than in the radial direction. Comparison of experimental research results with experimental results of other authors shows good agreement and the same tendency of thermal conductivity change. It is well known in the literature that the value of the heat transfer coefficient is the highest in the horizontal and the smallest in the vertical position of the heat exchange surface. Variation of heat transfer, depending on inclination angle is not examined in detail. The difference between the values of the relative heat transfer coefficient between vertical and horizontal heater position for all particle sizes reduces by approximately 15% with the increase of fluidization rate.

  7. Application Of Holographic Interferometry For Investigation Of Microroughness Of Engineering Surfaces

    Science.gov (United States)

    Lech, Marek; Mruk, Irena; Stupnicki, Jacek

    1985-01-01

    The paper describes an improved immersion method of holographic interferometry /IMHI/ adjusted for studies of roughness of engineering surfaces. Special optical arrangement, with two types of immersion cells and adequate technique of preparing transparent replicas reproducting with high fidelity details of differently machined surfaces was elaborated. It permits to obtain the contour maps of the surface asperities with intervals between the planes of succesive contour lines within a range of 1 μm. The results obtained for some engineering surfaces are given.

  8. On-Surface Synthesis by Click Chemistry Investigated by STM and XPS

    DEFF Research Database (Denmark)

    Vadapoo, Sundar Raja

    2014-01-01

    such as molecular electronics and surface functionalization. In this thesis, a well-defined click chemistry approach is followed, with the study of azide-alkyne cycloaddition on Cu(111) surface in UHV environment. A successful achievement of the click reaction product via on-surface synthesis has been shown, which...

  9. Structural investigation of the ZnSe(001)-c(2×2) surface

    DEFF Research Database (Denmark)

    Weigand, W.; Müller, A.; Kilian, L.

    2003-01-01

    Zinc selenide is a model system for II-VI compound semiconductors. The geometric structure of the clean (001)-c(2x2) surface has recently been the subject of intense debate. We report here a surface x-ray-diffraction study on the ZnSe(001)-c(2x2) surface performed under ultrahigh vacuum using...

  10. Further Investigation Into the Use of Laser Surface Preparation of Ti-6Al-4V Alloy for Adhesive Bonding

    Science.gov (United States)

    Palmieri, Frank L.; Crow, Allison; Zetterberg, Anna; Hopkins, John; Wohl, Christopher J.; Connell, John W.; Belcher, Tony; Blohowiak, Kay Y.

    2014-01-01

    Adhesive bonding offers many advantages over mechanical fastening, but requires robust materials and processing methodologies before it can be incorporated in primary structures for aerospace applications. Surface preparation is widely recognized as one of the key steps to producing robust and predictable bonds. This report documents an ongoing investigation of a surface preparation technique based on Nd:YAG laser ablation as a replacement for the chemical etch and/or abrasive processes currently applied to Ti-6Al-4V alloys. Laser ablation imparts both topographical and chemical changes to a surface that can lead to increased bond durability. A laser based process provides an alternative to chemical-immersion, manual abrasion, and grit blast process steps which are expensive, hazardous, environmentally unfriendly, and less precise. In addition, laser ablation is amenable to process automation, which can improve reproducibility to meet quality standards for surface preparation. An update on work involving adhesive property testing, surface characterization, surface stability, and the effect of laser surface treatment on fatigue behavior is presented. Based on the tests conducted, laser surface treatment is a viable replacement for the immersion chemical surface treatment processes. Testing also showed that the fatigue behavior of the Ti-6Al-4V alloy is comparable for surfaces treated with either laser ablation or chemical surface treatment.

  11. The structure and reactivity of adsorbates on stepped Rh and Pt surfaces investigated by LEED, HREELS, TPD, XPS and STM

    Energy Technology Data Exchange (ETDEWEB)

    Batteas, J.D. [Univ. of California, Berkeley, CA (United States). Dept. of Chemistry]|[Lawrence Berkeley Lab., CA (United States). Materials Science Div.

    1995-06-01

    Defects on surfaces such as steps play an important role in surface chemistry. In order to obtain an understanding of the influence of steps in surface chemical reactions, the structure and reactivity of small molecules (O{sub 2}, CO, H{sub 2}S, and C{sub 2}H{sub 4}) on atomically stepped surfaces of RH and Pt have been investigated. The detailed structures of CO and oxygen bonded to the Rh(110) surface were determined. The CO molecules bond near the short bridge sites with the CO molecular axis tilted approximately 24{degree} from the surface normal. Oxygen atoms are bound asymmetrically in the 3-fold fcc hollow-sites to the (111) facets of the steps. The interactions of CO and oxygen on the Rh(311) surface were examined. The reaction of CO with the ordered phases of O shows two distinct reaction channels, a low temperature reaction limited channel (200 K) and a high temperature diffusion limited channel (350 K). Models of the reaction geometry and dynamics are proposed. The thermal decomposition of ethylene was examined on the Rh(311) surface. The stable decomposition species (C{sub 2}H, CH and C{sub 2}) are formed near 300 K, approximately 100 K lower on the stepped Rh(311) than on the flatter Rh(111) surface. The formation of these species at lower temperatures is attributed to the stepped nature of the surface. Finally, in situ STM was used to examine surface structural changes of a stepped Pt(111) crystal under coadsorption of sulfur and CO. This is the first direct evidence for a new mechanism by which a surface covered with an unreactive, strongly chemisorbed overlayer can form new sites, for bonding and reactions to occur, by massive surface restructuring at the step edges. This new surface phenomenon answers some of the puzzles of metal surface catalysis and its implications are described. 278 refs.

  12. Loading of titanium implants with hydrophilic endosteal surface 3 weeks after insertion: clinical and radiological outcome of a 12-month prospective clinical trial.

    Science.gov (United States)

    Hinkle, Robert M; Rimer, Stephen R; Morgan, Michael H; Zeman, Paul

    2014-08-01

    The aim of this study was to test whether early loading (21 days after insertion) of implants with a hydrophilic surface is safe and reliable in a general clinical practice setting. This was a prospective multicenter clinical trial conducted in 3 independent surgical practices. Patients were selected according to predefined inclusion and exclusion criteria. Implants were placed in posterior regions into healed alveoli and native bone using a 1-stage (unsubmerged) surgical protocol. Loading was to be performed 21 days thereafter. Patients were followed clinically and radiographically for 1 year. Twenty-one patients who received 23 implants were followed for 1 year. None of the osseointegrated implants were lost. One broken provisional crown was reported during the trial period. The crestal bone remained remarkably stable (ie, approximately 1 mm below the microgap). The most coronal bone-to-implant contact stabilized at the level of the first implant thread just beneath the machined collar. Within the limitations of this clinical study, the authors confirmed that loading of implants with a hydrophilic surface 3 weeks after placement appears to be a safe and predictable treatment option. No crestal bone loss was observed 1 year after implant placement. Therefore, it appears that crestal bone loss is dependent on the design features of the specific implant line. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Controlling fatigue crack paths for crack surface marking and growth investigations

    Directory of Open Access Journals (Sweden)

    S. Barter

    2016-01-01

    Full Text Available While it is well known that fatigue crack growth in metals that display confined slip, such as high strength aluminium alloys, develop crack paths that are responsive to the loading direction and the local microstructural orientation, it is less well known that such paths are also responsive to the loading history. In these materials, certain loading sequences can produce highly directional slip bands ahead of the crack tip and by adjusting the sequence of loads, distinct fracture surface features or progression marks, even at very small crack depths can result. Investigating the path a crack selects in fatigue testing when particular combinations of constant and variable amplitude load sequences are applied is providing insight into crack growth. Further, it is possible to design load sequences that allow very small amounts of crack growth to be measured, at very small crack sizes, well below the conventional crack growth threshold in the aluminium alloy discussed here. This paper reports on observations of the crack path phenomenon and a novel test loading method for measuring crack growth rates for very small crack depths in aluminium alloy 7050-T7451 (an important aircraft primary structural material. The aim of this work was to firstly generate short- crack constant amplitude growth data and secondly, through the careful manipulation of the applied loading, to achieve a greater understanding of the mechanisms of fatigue crack growth in the material being investigated. A particular focus of this work is the identification of the possible sources of crack growth retardation and closure in these small cracks. Interpreting these results suggests a possible mechanism for why small fatigue crack growth through this material under variable amplitude loading is faster than predicted from models based on constant amplitude data alone.

  14. In-situ investigations of surface modifications by swift heavy ions

    International Nuclear Information System (INIS)

    Bolse, W.; Sankarakumar, A.; Ferhati, R.; Garmatter, D.; Haag, M.; Dautel, K.; Asdi, M.; Srivastava, N.; Widmann, B.; Bauer, M.

    2014-01-01

    We are running a High Resolution Scanning Electron Microscope in the beam line of the UNILAC ion accelerator at the GSI Helmholtz Centre for Heavy Ion Research in Danustadt, Germany, which has recently been extended also with an EDX-system and two micro-manipulators. This instrument allows us to in-situ investigate the structural and compositional development of individual objects and structures in the μm- and nm-range under swift heavy ion bombardment, from the very first ion impact up to high fluences of the order of several 10 15 /cm 2 . The sample under investigation is irradiated in small fluence steps and in between SEM-images (and EDX-scans) of one and the same surface area are taken. The irradiation can be carried out at any incidence angle between 0° and 90° and also under stepwise or continuous azimuthal rotation of the sample. The micro-manipulator system allows us to perform additional analysis like electrical and mechanical characterization as well as substrate-free EDX at sub-μm objects. We are now also able to irradiate almost free standing sub-μm structures (pasted on a nanoscale tip or held in micro-tweezers). In this report an overview over this unique instrument and its capabilities and advantages will be given, illustrated by the results of our recent in-situ studies on ion induced modification of thin films (dewetting and self-organisation) and on shaping of sub-μm objects with swift heavy ions (by taking advantage of ion sputtering, ion hammering and ion induced visco-elastic flow). (author)

  15. Investigation of the surface potential of TiO2 (110) by frequency-modulation Kelvin probe force microscopy.

    Science.gov (United States)

    Kou, Lili; Li, Yan Jun; Kamijyo, Takeshi; Naitoh, Yoshitaka; Sugawara, Yasuhiro

    2016-12-16

    We investigate the surface potential distribution on a TiO 2 (110)-1 × 1 surface by Kelvin probe force microscopy (KPFM) and atom-dependent bias-distance spectroscopic mapping. The experimental results demonstrate that the local contact potential difference increases on twofold-coordinated oxygen sites, and decreases on OH defects and fivefold-coordinated Ti sites. We propose a qualitative model to explain the origin of the surface potential of TiO 2 (110). We qualitatively calculate the surface potential induced by chemical potential and permanent surface dipole. The calculated results agree with our experimental ones. Therefore, we suggest that the surface potential of TiO 2 (110) is dominated not only by the permanent surface dipole between the tip apex atom and surface, but also by the dipoles induced by the chemical interaction between the tip and sample. The KPFM technique demonstrate the possibility of investigation of the charge transfer phenomenon on TiO 2 surface under gas conditions. It is useful for the elucidation of the mechanism of the catalytic reactions.

  16. Investigation of some properties of Nylon-6 surface treated by corona discharge in helium

    International Nuclear Information System (INIS)

    Dumitrascu, N.; Surdu, S.; Popa, Gh.; Raileanu, D.

    1996-01-01

    In this work an easy and less expensive method of treatment has been used by corona discharge. This allows to modify the surface properties and especially to improve the compatibility of polymers with biological tissue. The Nylon-6 as a test material was chosen. A scanning electron microscope to visualize the morphology of the morphology of the surface and an IR spectrophotometer able to identify the amide groups and other as well, have been used. Morphology of the treated surface by corona discharge emphasis an etching an etching and/or a crosslinking of amorphous domains, generally important to improve the properties as wetting, dyeing, adhesion, etc. Over all treated surface there is significant blood compatible properties without the need of heparinization of surface. The treated surface influences the biological behaviour of micro-organisms, respectively, that surface is a favourable medium for division of cells and may increase their lifetime. (authors)

  17. Investigation on the shockwave induced by surface arc plasma in quiescent air

    International Nuclear Information System (INIS)

    Jin Di; Li Ying-Hong; Jia Min; Li Fan-Yu; Cui Wei; Sun Quan; Zhang Bai-Ling; Li Jun

    2014-01-01

    The shockwave induced by surface direct-current (DC) arc discharge is investigated both experimentally and numerically. In the experiment, the shockwave generated by rapid gas heating is clearly observed from Schlieren images. The peak velocity of the shockwave is measured to be over 410 m/s; during its upright movement, it gradually falls to about 340 m/s; no remarkable difference is seen after changing the discharge voltage and the pulse frequency. In the modeling of the arc plasma, the arc domain is not simulated as a boundary condition with fixed temperature or pressure, but a source term with a time-varying input power density, which could better reflect the influence of the heating process. It is found that with a reference power density of 2.8×10 12 W/m 3 , the calculated peak velocity is higher than the measured one, but they quickly (in 30 μs) become agreed with each other. The peak velocity also rises while increasing the power density, the maximum velocity acquired in the simulation is over 468 m/s, which is expected to be effective for high speed flow control

  18. Investigating cyclic nucleotide and cyclic dinucleotide binding to HCN channels by surface plasmon resonance.

    Directory of Open Access Journals (Sweden)

    Sebastien Hayoz

    Full Text Available Hyperpolarization-activated cyclic nucleotide-modulated (HCN channels control cardiac and neuronal rhythmicity. HCN channels contain cyclic nucleotide-binding domain (CNBD in their C-terminal region linked to the pore-forming transmembrane segment with a C-linker. The C-linker couples the conformational changes caused by the direct binding of cyclic nucleotides to the HCN pore opening. Recently, cyclic dinucleotides were shown to antagonize the effect of cyclic nucleotides in HCN4 but not in HCN2 channels. Based on the structural analysis and mutational studies it has been proposed that cyclic dinucleotides affect HCN4 channels by binding to the C-linker pocket (CLP. Here, we first show that surface plasmon resonance (SPR can be used to accurately measure cyclic nucleotide binding affinity to the C-linker/CNBD of HCN2 and HCN4 channels. We then used SPR to investigate cyclic dinucleotide binding in HCN channels. To our surprise, we detected no binding of cyclic dinucleotides to the isolated monomeric C-linker/CNBDs of HCN4 channels with SPR. The binding of cyclic dinucleotides was further examined with isothermal calorimetry (ITC, which indicated no binding of cyclic dinucleotides to both monomeric and tetrameric C-linker/CNBDs of HCN4 channels. Taken together, our results suggest that interaction of the C-linker/CNBD with other parts of the channel is necessary for cyclic-dinucleotide binding in HCN4 channels.

  19. Investigation of game characteristics of elite tennis players on different surfaces.

    Directory of Open Access Journals (Sweden)

    Bülent KİLİT

    2017-03-01

    Full Text Available Aim: The purpose of this study was to investigation of game characteristics of elite tennis players on different surfaces (grass, clay and hard. Material and Methods: As a data collection tool used in the official web pages (www.rolandgarros.com, www.wimbledon.com, www.usopen.org in 2015 Grand Slam tennis tournaments. The study monitored the following game characteristics: 1st service %, aces, double faults, unforced error, winning % on 1st serve, winning % on 2nd serve, winners (including service, average 1st serve speed, average 2nd serve speed, average duration of games, average game number, total match duration, average duration of sets. One way ANOVA and Scheffe post-hoc test was performed in order to evaluate the game characteristics in this study. Results: Wimbledon had a significant more responses in terms of 1st service %, aces, winning % on 1st serve, average 1st and 2nd serve speed in male tennis players (p<0.05. For female tennis players, American open had more double faults, while Wimbledon had more aces, winning % on 1st Serve, winning % on 1st serve, average 1st and 2nd serve speed, winners responses (p<0.05. Conclusion: According to these results, serve values in fast court like Wimbledon were more than the others. Similar game characteristics were seen in French open (slow court and American open (medium court.

  20. Impacts of wildfires on interannual trends in land surface phenology: an investigation of the Hayman Fire

    Science.gov (United States)

    Wang, Jianmin; Zhang, Xiaoyang

    2017-05-01

    Land surface phenology (LSP) derived from satellite data has been widely associated with recent global climate change. However, LSP is frequently influenced by land disturbances, which significantly limits our understanding of the phenological trends driven by climate change. Because wildfire is one of the most significant disturbance agents, we investigated the influences of wildfire on the start of growing season (SOS) and the interannual trends of SOS in the Hayman Fire area that occurred in 2002 in Colorado using time series of daily MODIS data (2001-2014). Results show that the Hayman Fire advanced the area-integrated SOS by 15.2 d and converted SOS from a delaying trend of 3.9 d/decade to an advancing trend of -1.9 d/decade during 2001-2014. The fire impacts on SOS increased from low burn severity to high burn severity. Moreover, the rate of increase of annual maximum and minimum EVI2 from 2003-2014 reflects that vegetation greenness could recover to pre-fire status in 2022 and 2053, respectively, which suggests that the fire impacts on the satellite-derived SOS variability and the interannual trends should continue in the next few decades.

  1. Investigating thiol-modification on hyaluronan via carbodiimide chemistry using response surface methodology.

    Science.gov (United States)

    Santhanam, Sruthi; Liang, Jue; Baid, Rinku; Ravi, Nathan

    2015-07-01

    Hyaluronan (HA) is a naturally occurring glycosaminoglycan widely researched for its use as a biomaterial in tissue engineering, drug delivery, angiogenesis, and ophthalmic surgeries. The mechanical properties of this biomaterial can be altered to a required extent by chemically modifying the pendant reactive groups. However, derivatizing these polymers to a predetermined extent has been the Achilles heel for this process. In this study, we have investigated the factors controlling the derivatization of the carboxyl moieties of HA with amine containing thiol, cystamine dihydrochloride (Cys), via carbodiimide crosslinking chemistry. We used fractional factorial design to screen and identify the significant factor(s) affecting the reaction, and response surface methodology (RSM) to develop a model equation for predicting the degree of thiolation of HA. Also, we analyzed the reaction mechanism for potential side reactions. We observed that N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) (mole ratio with repeat unit of HA) is the significant factor controlling the degree of amidation. The quadratic equations developed from RSM predict the formulation for a desired degree of amidation of HA and percentage of potential side product. Hence, derivatizing HA to a predetermined extent with minimal side product can be achieved using the statistical design of experiments. © 2014 Wiley Periodicals, Inc.

  2. Investigation of benzene and toluene layers on 0001 surface of graphite by means of neutron scattering

    International Nuclear Information System (INIS)

    Monkenbusch, M.

    1981-01-01

    The structures of benzene (C 6 H 6 , C 6 D 6 ) and toluene (C 6 H 5 -CH 3 , C 6 D 5 -CD 3 ) monolayers on the basal planes of graphite have been investigated by neutron diffraction. The dynamics of the benzene layer has been studied by observing the incoherently, inelastically scattered neutrons using the time-of-flight method. The main results are: Above a phase transition temperature Tsub(c)approx.=145 K benzene on the basal planes of graphite forms a quasi 2D-fluid with high compressibility. For toluene a fluid phase exists above 140 K, between 70 K and 140 K it forms an incommensurate layer and below 70 K a 3x3 structure has been observed. The fluid phase of adsorbed benzene shows a broad quasielastic scattering indicating an effective surface diffusion coefficient of 10 -4 cm 2 /s at 200 K. The inelastic spectrum has been compared with an appropriate lattice dynamical model. The comparison with the data reveals, can be considered as a fairly anharmonic 2D-solid with a static external potential due to the substrate. (orig./HK)

  3. Radiological assessment of radioactive contamination on private clothing

    International Nuclear Information System (INIS)

    Schartmann, F.; Thierfeldt, S.

    2003-01-01

    In the very rare, cases where private clothing of persons working in a nuclear installation are inadvertently contaminated and this contamination is not detected when leaving the facility, there may be radiological consequences for this person as well as for members of his or her family. The VGB (Technische Vereinigung der Grosskraftwerksbetreiber) in Germany has investigated in detail the spread of contamination in nuclear power plants. Part of this evaluation programme was a radiological analysis which has been carried out by Brenk Systemplanung GmbH (Aachen/Germany). The radiological analysis started with the definition of the source term. It is highly unlikely that activities of more than 5 kBq 60 Co could leave a plant undetected on the body or the clothes. Nevertheless activities up to 50 kBq and different nuclide vectors were regarded. It has been found that 60 Co is the most important contaminant. The radiological analysis focusses on two types of contamination: particles and surface contamination. The pathways by which such a contamination can lead to an exposure by external irradiation or by ingestion depend on the type of contamination and are analysed in detail. For example, a particle could be retained in pockets or other parts of clothing and may lead to prolonged external irradiation until the piece of clothing is washed. The analysis is performed on the basis of conservative to realistic assumptions. In conclusion, the analysis has shown that especially particle contamination needs to be focussed on. However, by the advanced detection equipment in German plants doses which may pose a health hazard can safely be excluded. (authors)

  4. Report of the preliminary mission of radiological controls on the island of Mangareva and the atolls of Tureia and Hao (French Polynesia). Investigation performed by the CRIIRAD laboratory on the request of the inquiry Commission on consequences of atmospheric nuclear tests

    International Nuclear Information System (INIS)

    2006-01-01

    After a presentation of the objectives of the mission, and a summary of the undertaken actions on each site, this document gives some general information on radionuclides and on the sampling and analysis method. Then, it discusses the results obtained by radiological analyses and gives recommendations about the current radiological situation of the studied island and atolls. It shows that official assessment of radiation doses undergone by the French Polynesia population during the period atmospheric nuclear tests must be revised. It outlines the need of new exhaustive investigations on health consequences of these past exposures to ionizing radiation. Recommendations are formulated

  5. Adsorption of ethanol on V2O5 (010) surface for gas-sensing applications: Ab initio investigation

    International Nuclear Information System (INIS)

    Qin, Yuxiang; Cui, Mengyang; Ye, Zhenhua

    2016-01-01

    Highlights: • Ethanol adsorbed on V 2 O 5 (010) surface was investigated by ab initio calculations. • Ethanol prefers to adsorb on “Hill”-like surface, rather than“Valley”-like region. • Surface O 1(H) site plays a key role to dominate the ethanol adsorption process. • Sensing mechanism is related with electronic structure and electron redistribution. • Gas sensitivity is reflected by quantitative electron population analysis. - Abstract: The adsorption of ethanol on V 2 O 5 (010) surface was investigated by means of density functional theory (DFT) with a combined generalized gradient approximation (GGA) plus Hubbard U approach to exploit the potential sensing applications. The adsorption configurations were first constructed by considering different orientations of ethanol molecule to V and O sites on the “Hill”- and “Valley”-like regions of corrugated (010) surface. It is found that ethanol molecule can adsorb on whole surface in multiple stable configurations. Nevertheless the molecular adsorption on the “Hill”-like surface is calculated to occur preferentially, and the single coordinated oxygen on “Hill”-like surface (O 1(H) ) acting as the most energetically favorable adsorption site shows the strongest adsorption ability to ethanol molecule. Surface adsorption of ethanol tunes the electronic structure of V 2 O 5 and cause an n-doping effect. As a consequence, the Fermi levels shift toward the conductive bond increasing the charge carrier concentration of electrons in adsorbed V 2 O 5 . The sensitive electronic structure and the multiple stable configurations to ethanol adsorption highlight the high adsorption activity and then the potential of V 2 O 5 (010) surface applied to high sensitive sensor for ethanol vapor detection. Further Mulliken population and Natural bond orbital (NBO) calculations quantify the electron transfer from the adsorbed ethanol to the surface, and correlates the adsorption ability of surface sites

  6. Portrayal of radiology in a major medical television series: How does it influence the perception of radiology among patients and radiology professionals?

    International Nuclear Information System (INIS)

    Heye, T.; Merkle, E.M.; Boll, D.T.; Leyendecker, J.R.; Gupta, R.T.

    2016-01-01

    To assess how the portrayal of Radiology on medical TV shows is perceived by patients and radiology professionals. In this IRB-approved study with patient consent waived, surveys were conducted among adult patients scheduled for radiological examinations and radiology professionals. The questionnaire investigated medical TV watching habits including interest in medical TV shows, appearance of radiological examination/staff, radiology's role in diagnosis-making, and rating of the shows' accuracy in portraying radiology relative to reality. One hundred and twenty-six patients and 240 professionals (133 technologists, 107 radiologists) participated. 63.5 % patients and 63.2 % technologists rated interest in medical TV shows ≥5 (scale 1-10) versus 38.3 % of radiologists. All groups noted regular (every 2nd/3rd show) to >1/show appearance of radiological examinations in 58.5-88.2 % compared to 21.0-46.2 % for radiological staff appearance. Radiology played a role in diagnosis-making regularly to >1/show in 45.3-52.6 %. There is a positive correlation for interest in medical TV and the perception that radiology is accurately portrayed for patients (r = 0.49; P = 0.001) and technologists (r = 0.38; P = 0.001) but not for radiologists (r = 0.01). The majority of patients perceive the portrayed content as accurate. Radiologists should be aware of this cultivation effect to understand their patients' behaviour which may create false expectations towards radiological examinations and potential safety hazards. (orig.)

  7. Lumbar spine and pelvic posture between standing and sitting: a radiologic investigation including reliability and repeatability of the lumbar lordosis measure.

    Science.gov (United States)

    De Carvalho, Diana E; Soave, David; Ross, Kim; Callaghan, Jack P

    2010-01-01

    Sitting has been identified as a cause of mechanical low back pain. The purpose of this study was to use plain film x-rays to measure lumbar spine and pelvic posture differences between standing and sitting. Eight male subjects were radiographed standing and sitting in an automobile seat. Measures of lumbar lordosis, intervertebral disk angles, lumbosacral angle, lumbosacral lordosis, and sacral tilt were completed. One-way analysis of variance (alpha = .05) was conducted on the variables stated above. A Bland-Altman analysis was conducted to assess agreement and repeatability of the lumbar lordosis angle using 2 raters. Lumbar lordosis values in standing (average, 63 degrees +/- 15 degrees ) and sacral inclination (average, 43 degrees +/- 10 degrees ) decreased by 43 degrees and 44 degrees , respectively, in sitting. Intervertebral joint angles in sitting underwent substantial flexion (L1/L2-5 degrees [+/-3 degrees ], L2/L3-7 degrees [+/-3 degrees ], L3/L4-8 degrees [+/-3 degrees ], L4/L5-13 degrees [+/-3 degrees ], and L5/S1-4 degrees [+/-10 degrees ]). Measures of lumbar lordosis; intervertebral disk angles between L2/L3, L3/L4, and L4/L5; lumbosacral lordosis; lumbosacral angle; and sacral tilt were significantly decreased between standing and sitting (P sitting further emphasize the range of motion experienced at vertebral levels in sitting. Based on the results of this study, interventions to return motion segments to a less flexed posture should be investigated because they may play a role in preventing injury and low back pain. Copyright 2010 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  8. The Karachi intracranial stenosis study (KISS Protocol: An urban multicenter case-control investigation reporting the clinical, radiologic and biochemical associations of intracranial stenosis in Pakistan

    Directory of Open Access Journals (Sweden)

    Makki Karim

    2009-07-01

    Full Text Available Abstract Background Intracranial stenosis is the most common cause of stroke among Asians. It has a poor prognosis with a high rate of recurrence. No effective medical or surgical treatment modality has been developed for the treatment of stroke due to intracranial stenosis. We aim to identify risk factors and biomarkers for intracranial stenosis and to develop techniques such as use of transcranial doppler to help diagnose intracranial stenosis in a cost-effective manner. Methods/Design The Karachi Intracranial Stenosis Study (KISS is a prospective, observational, case-control study to describe the clinical features and determine the risk factors of patients with stroke due to intracranial stenosis and compare them to those with stroke due to other etiologies as well as to unaffected individuals. We plan to recruit 200 patients with stroke due to intracranial stenosis and two control groups each of 150 matched individuals. The first set of controls will include patients with ischemic stroke that is due to other atherosclerotic mechanisms specifically lacunar and cardioembolic strokes. The second group will consist of stroke free individuals. Standardized interviews will be conducted to determine demographic, medical, social, and behavioral variables along with baseline medications. Mandatory procedures for inclusion in the study are clinical confirmation of stroke by a healthcare professional within 72 hours of onset, 12 lead electrocardiogram, and neuroimaging. In addition, lipid profile, serum glucose, creatinine and HbA1C will be measured in all participants. Ancillary tests will include carotid ultrasound, transcranial doppler and magnetic resonance or computed tomography angiogram to rule out concurrent carotid disease. Echocardiogram and other additional investigations will be performed at these centers at the discretion of the regional physicians. Discussion The results of this study will help inform locally relevant clinical guidelines

  9. The Future of Radiology

    Directory of Open Access Journals (Sweden)

    Alexander R. Margulis

    2011-07-01

    Full Text Available It has been my good fortune to live and practice radiology during a long period of momentous change – to see the transformation of the discipline from a supportive service into a mainstream, essential branch of clinical medicine. I remember wearing red goggles to adapt my vision before performing fluoroscopy; observing the horrible, now thankfully obsolete, practice of ventriculography, which was considered advanced neuroradiology; and performing other, now rarely prescribed procedures, such as double-contrast barium enemas and intravenous pyelography. Witnessing the beginnings of interventional radiology, I suggested its name in an editorial. I also had the good fortune to see the introduction of computed tomography (CT and a technology first known as nuclear magnetic resonance imaging. Together with fellow members of a committee of the American College of Radiology and editors of prestigious radiological journals, I took part in changing the name of the latter modality to MRI, freeing it from threatening implications. Looking back on these experiences, one lesson stands out above all: Innovation and transformation never cease. Looking forward, it is clear that radiology, along with the rest of medicine, is now undergoing further momentous changes that will affect the future of all those already practicing as well as those yet to start their careers.

  10. XPS and FTIR investigation of the surface properties of different prepared titania nano-powders

    DEFF Research Database (Denmark)

    Jensen, Henrik; Solovyev, Alexey; Lie, Zheshen

    2005-01-01

    Surface studies of nano-sized TiO2 powders prepared by different methods showed that the preparation method had great impact on the surface properties. XPS measurements showed that the oxygen composition was related to the preparation method. The chloride method yielded the lowest amount of surface...... oxygen (29%) and sol–gel prepared powder showed the greatest amount of surface oxygen (66%) in the form of surface hydroxyl groups. The remaining oxygen was identified as lattice oxygen. The powder prepared by the sol–gel method contained carbon impurities originating from residual alkoxy groups....... Supercritical sol–gel prepared powder and powder prepared by the sulphate method revealed same trends regarding oxygen composition with 44–47% being surface oxygen; neither contained carbon impurities. The results obtained from XPS were confirmed by FTIR measurements....

  11. The Themis-Beagle families: Investigation of space-weathering processes on primitive surfaces

    Science.gov (United States)

    Fornasier, S.; Perna, D.; Lantz, C.; Barucci, M.

    2014-07-01

    In the past 20 years, enormous progress has been reached in the study of space-weathering (SW) effects on silicates and silicate asteroids. The so-called ordinary chondrite paradox, that is, lack of asteroids similar to the ordinary chondrites, which represent 80 % of meteorite falls, has been solved. These meteorites are now clearly related to S-type asteroids, as proved also by the direct measurements of the NEAR and HAYABUSA missions on the near-Earth asteroids Eros and Itokawa. Spectral differences between S-type asteroids and ordinary chondrites are caused by space-weathering effects, which produce a darkening in the albedo, a reddening of the spectra, and diminish the silicate absorption bands on the asteroids surfaces, exposed to cosmic radiation and solar wind. On the other hand, our understanding of space-weathering effects on primitive asteroids is still poor. Only few laboratory experiments have been devoted to the investigation of SW effects on dark carbonaceous chondrites and on complex organic materials. Irradiation of transparent organic materials produces firstly redder and darker materials that upon further processing turn flatter-bluish and darker (Kanuchova et al. 2012; Moroz et al. 2004). The Themis family is a natural laboratory to study primitive asteroids and space-weathering effects. The Themis family is located between 3.05 and 3.24 au, beyond the snow line, and it is composed of primitive asteroids. Themis is one of the most statistically reliable families in the asteroid belt. First discovered by Hirayama (1918), it has been identified as a family in all subsequent works, and it has 550 members as determined by Zappalà et al. (1995) and more than 4000 as determined by Nesvorny et al. (2010). The family formed probably about 2.3 Gyr ago as a result of a large-scale catastrophic disruption event of a parent asteroid 400 km in diameter colliding with a 190-km projectile (Marzari et al. 1995). Several Themis family members show absorption

  12. An Investigation of Ni2P Single Crystal Surfaces : Structure, Electronic State and Reactivity

    OpenAIRE

    Yuan, Qiuyi; Ariga, Hiroko; Asakura, Kiyotaka

    2015-01-01

    Ni2P has demonstrated high catalytic activity for hydrodesulfurization and has recently been employed as a catalyst in a variety of other reactions. We have thoroughly reviewed the literature concerning Ni2P single crystal surfaces, with the aim of determining the relationship between surface structure and catalytic properties. Published results to date indicate that Ni2P single crystal surfaces exhibit reconstructed structures, and so the bulk terminated structure may not be stable. We have ...

  13. Electrochemical investigation of the effect of different laser surface treatments on Hastelloy G alloy

    Energy Technology Data Exchange (ETDEWEB)

    Toor, Ihsan H.; Yilbas, Bekir S.; Hussein, Mohammed A.; Zafar, Mohammed N. [King Fahd Univ. of Petroleum and Minerals (KFUPM), Dhahran (Saudi Arabia). Dept. of Mechanical Engineering; Karatas, Cihan [Hacettepe Univ., Ankara (Turkey). Engineering Faculty

    2013-10-15

    In the present study, the corrosion resistance behavior of untreated and laser treated Hastelloy was examined. The electrochemical tests including potentiodynamic polarization, Tafel analysis, and linear polarization resistance were carried out in deaerated 0.5% NaCl aqueous solution at room temperature. Surface roughness was measured to correlate it with corrosion resistance properties of the materials. Surface morphology of the samples after corrosion tests was examined using scanning electron microscopy and energy dispersive X-ray spectroscopy. Results showed that laser treated surface exhibited better corrosion resistance properties as compared to untreated surface. (orig.)

  14. Anesthesia for radiologic procedures

    International Nuclear Information System (INIS)

    Forestner, J.E.

    1987-01-01

    Anesthetic techniques for neurodiagnostic studies and radiation therapy have been recently reviewed, but anesthetic involvement in thoracic and abdominal radiology has received little attention. Patient reactions to radiologic contrast media may be of concern to the anesthesiologist, who is often responsible for injecting these agents during diagnostic procedures, and thus is included in this discussion. Finally, the difficulties of administering anesthesia for magnetic resonance imaging (MRI) scans are outlined, in an effort to help anesthesiologist to anticipate problems with this new technologic development. Although there are very few indications for the use of general anesthesia for diagnostic radiologic studies in adults, most procedures performed with children, the mentally retarded, or the combative adult require either heavy sedation or general anesthesia. In selecting an anesthetic technique for a specific procedure, both the patient's disease process and the requirements of the radiologist must be carefully balanced

  15. KAERI Radiological Emergency Plan

    Energy Technology Data Exchange (ETDEWEB)

    Oui, Khang Byung; Lee, Goan Yup; Lee, Jong Tai

    2004-06-15

    The Radiological Emergency Plan of KAERI is to draw up based on the Civil Defence Law, the Disaster and Safety Management Law, the Act of Physical Protection and Emergency Preparedness in Nuclear Facilities, the National Radiological Emergency Plan, and made reference to the DOE order and IAEA TECDOC etc. This plan describes the preventive measures, emergency response, re-entry and restoration to ensure adequate response capabilities to the nuclear accidents which would cause a significant risk to the KAERI staffs and the public near to the site. And the Operation of Radiological Emergency Management System is included in this plan to test the effectiveness of this plan and to improve the response capabilities of the emergency staffs against nuclear accidents.

  16. Research on photoconductor radiological sensors

    International Nuclear Information System (INIS)

    Beaumont, Francois

    1989-01-01

    Because of the evolution of medical imaging techniques to digital systems, it is necessary to replace radiological film which has many drawbacks, by a detector quite as efficient and quickly giving a digitable signal. The purpose of this thesis is to find new X-ray digital imaging processes using photoconductor materials such as amorphous selenium. After reviewing the principle of direct radiology and functions to be served by the X-ray sensor (i e. detection, memory, assignment, visualization), we explain specification. We especially show the constraints due to the object to be radio-graphed (condition of minimal exposure), and to the reading signal (electronic noise detection associated with a reading frequency). As a result of this study, a first photoconductor sensor could be designed. Its principle is based on photo carrier trapping at dielectric-photoconductor structure interface. The reading system needs the scanning of a laser beam upon the sensor surface. The dielectric-photoconductor structure enabled us to estimate the possibilities offered by the sensor and to build a complete x-ray imaging system. The originality of thermos-dielectric sensor, that was next studied, is to allow a thermal assignment reading. The chosen system consists in varying the ferroelectric polymer capacity whose dielectric permittivity is weak at room temperature. The thermo-dielectric material was studied by thermal or Joule effect stimulation. During our experiments, trapping was found in a sensor made of amorphous selenium between two electrodes. This new effect was performed and enabled us to expose a first interpretation. Eventually, the comparison of these new sensor concepts with radiological film shows the advantage of the proposed solution. (author) [fr

  17. Numerical investigation of radiative properties and surface plasmon resonance of silver nanorod dimers on a substrate

    International Nuclear Information System (INIS)

    An, Wei; Zhu, Tong; Zhu, QunZhi

    2014-01-01

    When the distance between two silver nanoparticles is small enough, interparticle surface plasmon coupling has a great impact on their radiative properties. It is becoming a promising technique to use in the sensing and imaging. A model based on finite difference time domain method is developed to investigate the effect of the assembled parameters on the radiative properties and the field-enhancement effect of silver nanorod dimer. The numerical results indicate that the radiative properties of silver nanorod dimer are very sensitive to the assembled angle and the polarization orientation of incident wave. There is great difference on the intensity and location of field-enhancement effect for the cases of different assembled angle and polarization. The most intensive field-enhancement effect occurs in the middle of two nanorods when two nanorods is assembled head to head and the polarization orientation parallels to the length axis of nanorods. Moreover, compared with the single nanorod, the wavelength of extinction peak of dimer has a red-shift, and the intensity of field-enhancement effect on the dimer is more intensive than that of single particle. With the increasing of particle length, extinction cross-section of silver nanorod dimer rises, while extinction efficiency and scattering efficiency firstly increase then drop down gradually. In addition, the extinction peaks of silver nanorod dimer on the substrate are smaller than that without the substrate, and their extinction peaks has a red-shift compared with that without the substrate. -- Highlights: ► Radiative properties of silver nanorod dimer are very sensitive to the assembled angle. ► The projective length of nanorod dimer on the polarization orientation is crucial. ► Compared with single nanorod, wavelength of extinction peak of dimer has a red-shift. ► Extinction peaks of dimer on the substrate are smaller than that without the substrate

  18. Uniform-sized silicone oil microemulsions: preparation, investigation of stability and deposition on hair surface.

    Science.gov (United States)

    Nazir, Habiba; Lv, Piping; Wang, Lianyan; Lian, Guoping; Zhu, Shiping; Ma, Guanghui

    2011-12-01

    Emulsions are commonly used in foods, pharmaceuticals and home-personal-care products. For emulsion based products, it is highly desirable to control the droplet size distribution to improve storage stability, appearance and in-use property. We report preparation of uniform-sized silicone oil microemulsions with different droplets diameters (1.4-40.0 μm) using SPG membrane emulsification technique. These microemulsions were then added into model shampoos and conditioners to investigate the effects of size, uniformity, and storage stability on silicone oil deposition on hair surface. We observed much improved storage stability of uniform-sized microemulsions when the droplets diameter was ≤22.7 μm. The uniform-sized microemulsion of 40.0 μm was less stable but still more stable than non-uniform sized microemulsions prepared by conventional homogenizer. The results clearly indicated that uniform-sized droplets enhanced the deposition of silicone oil on hair and deposition increased with decreasing droplet size. Hair switches washed with small uniform-sized droplets had lower values of coefficient of friction compared with those washed with larger uniform and non-uniform droplets. Moreover the addition of alginate thickener in the shampoos and conditioners further enhanced the deposition of silicone oil on hair. The good correlation between silicone oil droplets stability, deposition on hair and resultant friction of hair support that droplet size and uniformity are important factors for controlling the stability and deposition property of emulsion based products such as shampoo and conditioner. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Experimental and theoretical investigations of the adhesion time of Penicillium spores to cedar wood surface

    International Nuclear Information System (INIS)

    Soumya, Elabed; Saad, Ibnsouda Koraichi; Abdellah, Houari; Hassan, Latrache

    2013-01-01

    In this study, the adhesion of 4 Penicillium strains (Penicillium granulatum, Penicillium crustosum, Penicillium commune and Penicillium chrysogenum) on cedar wood was examined qualitatively and quantitatively by using the extended DLVO (XDLVO) approach and the environmental scanning electronic microscopy (ESEM) technique. A comparison between the XDLVO theories and the ESEM technique was also investigated. The adhesion tests revealed that P. chrysogenum was not able to adhere on the cedar wood substrata, as predicted by the XDLVO approach. We have also found by ESEM that the three Penicillium strains (P. granulatum, P. crustosum, P. commune) adhered on wood, as not predicted theoretically. Moreover, the time of adhesion (3 h and 24 h) was used not only to compare the capacity of adhesion according to contact time but also to explain the discrepancies between the XDLVO approach prediction and the adhesion experiments. A positive relationship between the XDLVO approach and adhesion experiments has been observed after 3 h of adhesion. In contrast, a contradiction between the XDLVO predictions and the adhesion test results has been noted after 24 h of adhesion of Penicillium strains to the wood surface. Highlights: ► Calculation of free energy of adhesion to cedar wood of Penicillium by XDLVO approach ► Adhesion is not favorable for all Penicillium spores–cedar wood combinations. ► Adhesion tests demonstrated the ability of Penicillium spores to adhere to cedar wood. ► XDLVO approach correlated well with the results obtained after 3 h of adhesion. ► Discrepancy between XDLVO predictions and experimental observations at 24 h of adhesion

  20. Experimental and theoretical investigations of the adhesion time of Penicillium spores to cedar wood surface

    Energy Technology Data Exchange (ETDEWEB)

    Soumya, Elabed [Laboratoire de Biotechnologie Microbienne, Faculté des Sciences et Techniques de Fès-Saïs (Morocco); Université Sidi Mohamed Ben Abdellah, Centre Universitaire Régional d' Interface-Fès (Morocco); Saad, Ibnsouda Koraichi, E-mail: ibnsouda@hotmail.com [Laboratoire de Biotechnologie Microbienne, Faculté des Sciences et Techniques de Fès-Saïs (Morocco); Université Sidi Mohamed Ben Abdellah, Centre Universitaire Régional d' Interface-Fès (Morocco); Abdellah, Houari [Laboratoire de Biotechnologie Microbienne, Faculté des Sciences et Techniques de Fès-Saïs (Morocco); Hassan, Latrache [Laboratoire de Valorisation et de Sécurité des Produits Agroalimentaires, Faculté des Sciences et Techniques de Beni Mellal (Morocco)

    2013-04-01

    In this study, the adhesion of 4 Penicillium strains (Penicillium granulatum, Penicillium crustosum, Penicillium commune and Penicillium chrysogenum) on cedar wood was examined qualitatively and quantitatively by using the extended DLVO (XDLVO) approach and the environmental scanning electronic microscopy (ESEM) technique. A comparison between the XDLVO theories and the ESEM technique was also investigated. The adhesion tests revealed that P. chrysogenum was not able to adhere on the cedar wood substrata, as predicted by the XDLVO approach. We have also found by ESEM that the three Penicillium strains (P. granulatum, P. crustosum, P. commune) adhered on wood, as not predicted theoretically. Moreover, the time of adhesion (3 h and 24 h) was used not only to compare the capacity of adhesion according to contact time but also to explain the discrepancies between the XDLVO approach prediction and the adhesion experiments. A positive relationship between the XDLVO approach and adhesion experiments has been observed after 3 h of adhesion. In contrast, a contradiction between the XDLVO predictions and the adhesion test results has been noted after 24 h of adhesion of Penicillium strains to the wood surface. Highlights: ► Calculation of free energy of adhesion to cedar wood of Penicillium by XDLVO approach ► Adhesion is not favorable for all Penicillium spores–cedar wood combinations. ► Adhesion tests demonstrated the ability of Penicillium spores to adhere to cedar wood. ► XDLVO approach correlated well with the results obtained after 3 h of adhesion. ► Discrepancy between XDLVO predictions and experimental observations at 24 h of adhesion.

  1. Laboratory investigation and direct numerical simulation of wind effect on steep surface waves

    Science.gov (United States)

    Troitskaya, Yuliya; Sergeev, Daniil; Druzhinin, Oleg; Ermakova, Olga

    2015-04-01

    The small scale ocean-atmosphere interaction at the water-air interface is one of the most important factors determining the processes of heat, mass, and energy exchange in the boundary layers of both geospheres. Another important aspect of the air-sea interaction is excitation of surface waves. One of the most debated open questions of wave modeling is concerned with the wind input in the wave field, especially for the case of steep and breaking waves. Two physical mechanisms are suggested to describe the excitation of finite amplitude waves. The first one is based on the treatment of the wind-wave interaction in quasi-linear approximation in the frameworks of semi-empirical models of turbulence of the low atmospheric boundary layer. An alternative mechanism is associated with separation of wind flow at the crests of the surface waves. The "separating" and "non-separating" mechanisms of wave generation lead to different dependences of the wind growth rate on the wave steepness: the latter predicts a decrease in the increment with wave steepness, and the former - an increase. In this paper the mechanism of the wind-wave interaction is investigated basing on physical and numerical experiments. In the physical experiment, turbulent airflow over waves was studied using the video-PIV method, based on the application of high-speed video photography. Alternatively to the classical PIV technique this approach provides the statistical ensembles of realizations of instantaneous velocity fields. Experiments were performed in a round wind-wave channel at Institute of Applied Physics, Russian Academy of Sciences. A fan generated the airflow with the centerline velocity 4 m/s. The surface waves were generated by a programmed wave-maker at the frequency of 2.5 Hz with the amplitudes of 0.65 cm, 1.4 cm, and 2 cm. The working area (27.4 × 10.7 cm2) was at a distance of 3 m from the fan. To perform the measurements of the instantaneous velocity fields, spherical polyamide

  2. Radiologic protection in pediatric radiology: ICRP recommendations

    International Nuclear Information System (INIS)

    Sanchez, Ramon; Khong, Pek-Lan; Ringertz, Hans

    2013-01-01

    ICRP has provided an updated overview of radiation protection principles in pediatric radiology. The authors recommend that staff, radiologists, medical physicists and vendors involved in pediatric radiology read this document. For conventional radiography, the report gives advice on patient positioning, immobilization, shielding and appropriate exposure conditions. It describes extensively the use of pulsed fluoroscopy, the importance of limiting fluoroscopy time, and how shielding and geometry must be used to avoid unnecessary radiation to the patient and operator. Furthermore, the use of fluoroscopy in interventional procedures with emphasis on dose reduction to patients and staff is discussed in light of the increasing frequency, complexity and length ofthe procedures. CT is the main reason that medical imaging in several developed countries is the highest annual per capita effective radiation dose from man-made sources. The ICRP report gives extensive descriptions of how CT protocols can be optimized to minimize radiation exposure in pediatric patients. The importance of balancing image quality with acceptable noise in pediatric imaging and the controversies regarding the use of protective shielding in CT are also discussed.

  3. Radiologic protection in pediatric radiology: ICRP recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Ramon [University of Michigan Hospital, Department of Radiology, C. S. Mott Children' s Hospital, Ann Arbor, MI (United States); Khong, Pek-Lan [The University of Hong Kong, Department of Diagnostic Radiology, Queen Mary Hospital, Hong Kong (China); Ringertz, Hans [Linkoeping University Hospital, Center for Medical Image Science and Visualization, Linkoeping (Sweden)

    2013-08-15

    ICRP has provided an updated overview of radiation protection principles in pediatric radiology. The authors recommend that staff, radiologists, medical physicists and vendors involved in pediatric radiology read this document. For conventional radiography, the report gives advice on patient positioning, immobilization, shielding and appropriate exposure conditions. It describes extensively the use of pulsed fluoroscopy, the importance of limiting fluoroscopy time, and how shielding and geometry must be used to avoid unnecessary radiation to the patient and operator. Furthermore, the use of fluoroscopy in interventional procedures with emphasis on dose reduction to patients and staff is discussed in light of the increasing frequency, complexity and length ofthe procedures. CT is the main reason that medical imaging in several developed countries is the highest annual per capita effective radiation dose from man-made sources. The ICRP report gives extensive descriptions of how CT protocols can be optimized to minimize radiation exposure in pediatric patients. The importance of balancing image quality with acceptable noise in pediatric imaging and the controversies regarding the use of protective shielding in CT are also discussed.

  4. Radiology's value chain.

    Science.gov (United States)

    Enzmann, Dieter R

    2012-04-01

    A diagnostic radiology value chain is constructed to define its main components, all of which are vulnerable to change, because digitization has caused disaggregation of the chain. Some components afford opportunities to improve productivity, some add value, while some face outsourcing to lower labor cost and to information technology substitutes, raising commoditization risks. Digital image information, because it can be competitive at smaller economies of scale, allows faster, differential rates of technological innovation of components, initiating a centralization-to-decentralization technology trend. Digitization, having triggered disaggregation of radiology's professional service model, may soon usher in an information business model. This means moving from a mind-set of "reading images" to an orientation of creating and organizing information for greater accuracy, faster speed, and lower cost in medical decision making. Information businesses view value chain investments differently than do small professional services. In the former model, producing a better business product will extend image interpretation beyond a radiologist's personal fund of knowledge to encompass expanding external imaging databases. A follow-on expansion with integration of image and molecular information into a report will offer new value in medical decision making. Improved interpretation plus new integration will enrich and diversify radiology's key service products, the report and consultation. A more robust, information-rich report derived from a "systems" and "computational" radiology approach will be facilitated by a transition from a professional service to an information business. Under health care reform, radiology will transition its emphasis from volume to greater value. Radiology's future brightens with the adoption of a philosophy of offering information rather than "reads" for decision making. Staunchly defending the status quo via turf wars is unlikely to constitute a

  5. Tribological investigations of the applicability of surface functionalization for dry extrusion processes

    Science.gov (United States)

    Teller, Marco; Prünte, Stephan; Ross, Ingo; Temmler, André; Schneider, Jochen M.; Hirt, Gerhard

    2017-10-01

    Cold extrusion processes are characterized by large relative contact stresses combined with a severe surface enlargement of the workpiece. Under these process conditions a high risk for galling of workpiece material to the tool steel occurs especially in processing of aluminum and aluminum alloys. In order to reduce adhesive wear lubricants for separation of workpiece and tool surfaces are used. As a consequence additional process steps (e.g. preparation and cleaning of workpieces) are necessary. Thus, the realization of a dry forming process is aspired from an environmental and economic perspective. In this paper a surface functionalization with self-assembled-monolayers (SAM) of the tool steels AISI D2 (DIN 1.2379) and AISI H11 (DIN 1.2343) is evaluated by a process-oriented tribological test. The tribological experiment is able to resemble and scale the process conditions of cold extrusion related to relative contact stress and surface enlargement for the forming of pure aluminum (Al99.5). The effect of reduced relative contact stress, surface enlargement and relative velocity on adhesive wear and tool lifetime is evaluated. Similar process conditions are achievable by different die designs with decreased extrusion ratios and adjusted die angles. The effect of surface functionalization critically depends on the substrate material. The different microstructure and the resulting differences in surface chemistry of the two tested tool steels appear to affect the performance of the tool surface functionalization with SAM.

  6. Investigation of Selected Surface Integrity Features of Duplex Stainless Steel (DSS) after Turning

    Czech Academy of Sciences Publication Activity Database

    Krolczyk, G.; Nieslony, P.; Legutko, S.; Hloch, Sergej; Samardžić, I.

    2015-01-01

    Roč. 54, č. 1 (2015), s. 91-94 ISSN 0543-5846 Institutional support: RVO:68145535 Keywords : duplex stainless steel * machining * turning * surface integrity * surface roughness Subject RIV: JQ - Machines ; Tools Impact factor: 0.959, year: 2014 http://hrcak.srce.hr/126702

  7. Spectroscopic ellipsometric investigation of clean and oxygen covered copper single crystal surfaces

    NARCIS (Netherlands)

    Hanekamp, L.J.; Lisowski, W.F.; Bootsma, G.A.

    1982-01-01

    Spectroscopic ellipsometric measurements (400–820 nm) have been performed on clean and oxygen covered Cu(110) and Cu(111) surfaces in an AES-LEED UHV system. The complex dielectric functions of the clean surfaces were calculated from measurements between room temperature and 600 K. In contrast with

  8. Radiological control in a mine with a naturally-occurring radioactive material -NORM: III assessment of removable surface contamination in a pilot plant

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, W.S.; Py Junior, D.A.; Silva, A.C.A.; Garcia Filho, O., E-mail: pereiraws@gmail.com [Industrias Nucleares do Brasil (INB), Pocos de Caldas, MG (Brazil). Unidade de Tratamento de Minerio. Grupo Multidisciplinar de Radioprotecao; Kelecom, A., E-mail: akelecom@id.uff.br [Universidade Federal Fluminense (GETA/LARARA-PLS/UFF), Niteroi, RJ, (Brazil). Grupo de Estudos em Temas Ambientais. Lab. de Radiobiologia e Radiometria; Pereira, J.R.S., E-mail: pereirarsj@gmail.com [Universidade Federal de Alfenas (UNIFAL), Pocos de Caldas, MG (Brazil)

    2013-07-01

    Ore Treatment Unit (OUT) possesses a process laboratory. Considering the uranium ore processing, this laboratory works in close cooperation with the Radiation Protection Service of the Unit. In the year of 2009 a pilot plant for the development of solvent uranium extraction from the phosphate ore of the mine of Santa Quiteria city, in Ceara State, Brazil was developed. In this kind of plant the surface contamination may cause contamination for Occupational Exposed Individuals (OEI). In order to control this kind of contamination and offer a safety work's condition for OEIs, a monitoring program of transferable contamination using swab samples was developed. 162 swabs were made. For the alpha emitters the monitoring results varied from 0.001 Bq cm{sup -2} to 0.014 Bq cm{sup -2}, with average value of 0.002 Bq cm{sup -2}. For beta emitters the results varied from 0.010 Bq cm{sup -2} to 0.031 Bq cm{sup -2} with average equal to 0.011 Bq cm{sup -2}. For alpha emitters, 87.65 % of the results were below 0.004 Bq cm{sup -2}, values that are one order of magnitude smaller than the limit and the maximum value stayed in 35 % of the limit for an object to be considered contaminated. For beta emitters, 90 % of the results were below 0.010 Bq cm{sup -2} that corresponds to 25 % of the limit and 100 % were below 0.031 Bq cm{sup -2} below the limit for an object to be considered contaminated. In both cases any object monitored during the operation, was not considered contaminated, proving the good practices employed in the laboratory, resultant of the good planning of the Radiation Protection Service for the operations' process. (author)

  9. Radiology education: a radiology curriculum for all medical students?

    NARCIS (Netherlands)

    Zwaan, Laura; Kok, E.M.; van der Gijp, Anouk

    2017-01-01

    Diagnostic errors in radiology are frequent and can cause severe patient harm. Despite large performance differences between radiologists and non-radiology physicians, the latter often interpret medical images because electronic health records make images available throughout the hospital. Some

  10. Investigation of the surface free energy of the ITO thin films deposited under different working pressure

    International Nuclear Information System (INIS)

    Özen, Soner; Pat, Suat; Korkmaz, Şadan; Şenay, Volkan

    2016-01-01

    This study discusses the influence of working pressure on the surface energy of the ITO thin films produced by radio frequency magnetron sputtering method. Optical tensiometer (Attension Theta Lite) is used for evaluating wetting behavior of the water droplet on the film surface and Equation of State method was selected to determine surface free energy for this study. Equation of state method does not divide the surface tension into different components such as polar, dispersive, acid-base. It is calculated the surfaces’ free energy measuring the contact angle with a single liquid. The surface free energy value was in the range of 15-31 mN/m. Also, the transmittances were determined in the wavelength range between 200 and 1000 nm using the UNICO 4802 UV-Vis double beam spectrophotometer. Transmittances of the produced ITO thin films are greater than %70 in the visible range.

  11. Investigation of the surface free energy of the ITO thin films deposited under different working pressure

    Energy Technology Data Exchange (ETDEWEB)

    Özen, Soner, E-mail: osoner@ogu.edu.tr; Pat, Suat; Korkmaz, Şadan [Eskişehir Osmangazi University, Physics Department, 26480 (Turkey); Şenay, Volkan [Eskişehir Osmangazi University, Physics Department, 26480 (Turkey); Bayburt University, Primary Science Education Department, 69000 (Turkey)

    2016-03-25

    This study discusses the influence of working pressure on the surface energy of the ITO thin films produced by radio frequency magnetron sputtering method. Optical tensiometer (Attension Theta Lite) is used for evaluating wetting behavior of the water droplet on the film surface and Equation of State method was selected to determine surface free energy for this study. Equation of state method does not divide the surface tension into different components such as polar, dispersive, acid-base. It is calculated the surfaces’ free energy measuring the contact angle with a single liquid. The surface free energy value was in the range of 15-31 mN/m. Also, the transmittances were determined in the wavelength range between 200 and 1000 nm using the UNICO 4802 UV-Vis double beam spectrophotometer. Transmittances of the produced ITO thin films are greater than %70 in the visible range.

  12. Westinghouse radiological containment guide

    International Nuclear Information System (INIS)

    Aitken, S.B.; Brown, R.L.; Cantrell, J.R.; Wilcox, D.P.

    1994-03-01

    This document provides uniform guidance for Westinghouse contractors on the implementation of radiological containments. This document reflects standard industry practices and is provided as a guide. The guidance presented herein is consistent with the requirements of the DOE Radiological Control Manual (DOE N 5480.6). This guidance should further serve to enable and encourage the use of containments for contamination control and to accomplish the following: Minimize personnel contamination; Prevent the spread of contamination; Minimize the required use of protective clothing and personal protective equipment; Minimize the generation of waste

  13. Anesthesia for interventional radiology

    International Nuclear Information System (INIS)

    van Sonnenberg, E.; Casola, G.; Varney, R.R.; D'Agostino, H.B.; Zornow, M.; Mazzie, W.

    1989-01-01

    We recognized that the complexity and surgical nature of many interventional radiology procedures dictate essential radiologic involvement into traditional anesthesiologic areas. They reviewed our experience with a variety of interventional procedures to document complications and problems related to anesthetic use (or misuse) and compile recommendations for rational monitoring and control for these procedures. In particular, the authors have studied complications of drug therapies and the treatment of these complications; use of complex anesthesia procedures (e.g., epidural anesthesia, succinylcholine blockage); reasons for choice of drugs (e.g., fentanyl vs meperidine vs morphine); and medico-legal aspects of radiologist performing traditional anesthesiology-type procedures

  14. Practical interventional radiology

    International Nuclear Information System (INIS)

    Lammer, J.; Schreyer, H.

    1991-01-01

    The book is intended as a practical guide and manual for interventional radiology applications. Main emphasis is placed on the performance of the various techniques, with explanations of the various steps to be taken, illustrated by drawings or pictures. Indications, contra-indications and clinical achievements are given in brief. There is one chapter each for the following techniques: angioplasty - intra-arterial fibrinolysis - vascular stents - neuroembolisation - embolisation of other vessels - biliary interventions - abscess drainage - nephrostomy and ureteral manipulations -percutaneous fine-needle biopsy - vena cava filters - interventional radiology in infants. (orig.)

  15. Radiological worker training

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-10-01

    This Handbook describes an implementation process for core training as recommended in Implementation Guide G441.12, Radiation Safety Training, and as outlined in the DOE Radiological Control Standard (RCS). The Handbook is meant to assist those individuals within the Department of Energy, Managing and Operating contractors, and Managing and Integrating contractors identified as having responsibility for implementing core training recommended by the RCS. This training is intended for radiological workers to assist in meeting their job-specific training requirements of 10 CFR 835. While this Handbook addresses many requirements of 10 CFR 835 Subpart J, it must be supplemented with facility-specific information to achieve full compliance.

  16. Synopsis of radiologic anatomy

    International Nuclear Information System (INIS)

    Meschan, I.

    1987-01-01

    The book is a compact version of earlier publications that appeared in 1975 as a one- and a two-volume issue under the title 'Atlas of Radiologic Anatomy'. A chapter on computed tomography has been added as this novel technique requires a new approach to radiologic anatomy. The radiologist will find all the information on the anatomic conditions he needs for analysing radiographs and CT pictures. More than 600 radiographs and CT pictures are given that illustrate typical and rare findings. The book also is useful as a source of reference for making good radiographs and evaluating the quality of radiographs or CT pictures. With 1413 figs., 18 tabs [de

  17. Gastrointestinal and hepatobiliary radiology

    International Nuclear Information System (INIS)

    Graham, R.N.J.; Perriss, R.W.; Scarsbrook, A.F.

    2006-01-01

    This is the fifth in the series of short reviews of internet-based radiological learning resources and will focus on gastrointestinal (GI) and hepatobiliary radiology. Below are details of a few of the higher quality resources currently available. Most of the sites cater for medical students and trainee or non-specialist radiologists, but may be also be of interest to specialists, especially for use in teaching. Hyperlinks are available in the electronic version of this article and were all active at the time of going to press (May 2006)

  18. Radiological worker training

    International Nuclear Information System (INIS)

    1998-10-01

    This Handbook describes an implementation process for core training as recommended in Implementation Guide G441.12, Radiation Safety Training, and as outlined in the DOE Radiological Control Standard (RCS). The Handbook is meant to assist those individuals within the Department of Energy, Managing and Operating contractors, and Managing and Integrating contractors identified as having responsibility for implementing core training recommended by the RCS. This training is intended for radiological workers to assist in meeting their job-specific training requirements of 10 CFR 835. While this Handbook addresses many requirements of 10 CFR 835 Subpart J, it must be supplemented with facility-specific information to achieve full compliance

  19. Normal radiological findings

    International Nuclear Information System (INIS)

    Moeller, T.B.

    1987-01-01

    This book is intended for learners in radiology, presenting a wealth of normal radiological findings together with a systematic guide for appraisal and interpretation, and for formulation of reports. The text examples and criteria given will help beginners in learning to 'read' a radiograph, and to verify their conclusions by means of checklists and standard reports. The case material covers numerous illustrations from the following sectors: Skeletal radiography, mammography, tomography, contrast radiography, organ examination by intravenous techniques, arthrography and angiography, and specialized radiography, (ECB) With 184 figs [de

  20. Radiological sciences dictionary

    CERN Document Server

    Dowsett, David

    2009-01-01

    The Radiological Sciences Dictionary is a rapid reference guide for all hospital staff employed in diagnostic imaging, providing definitions of over 3000 keywords as applied to the technology of diagnostic radiology.Written in a concise and easy to digest form, the dictionary covers a wide variety of subject matter, including:· radiation legislation and measurement · computing and digital imaging terminology· nuclear medicine radionuclides and radiopharmaceuticals· radiographic contrast agents (x-ray, MRI and ultrasound)· definitions used in ultrasound and MRI technology· statistical exp

  1. Sampling on radiological protection training in diagnostic radiology

    International Nuclear Information System (INIS)

    Gaona, E.

    2001-01-01

    Radiological security aspects were evaluated in radiology departments from Mexico City. The study was carried out in two stages, the first one evaluated 40 departments just before the implementation of the new Official Mexican Standards related to Radiological Security and Quality Control in Radiology; in the second stage 33 departments were evaluated 2 years after those standards were implanted, showing a favorable impact of the training programs for the type of answers obtained [es

  2. Estimation of patient radiation doses during radiologic examinations in the Republic of Haiti

    International Nuclear Information System (INIS)

    Massillon, J.G.; Borras, C.

    2001-01-01

    The International Commission on Radiological Protection and the international organizations that co-sponsored the International Basic Safety Standards for the Protection against Ionization Radiation and for the Safety of Radiation Sources (BSS) - among them PAHO and WHO - recommended the use of investigation levels to provide guidance for medical exposures. In this work, entrance surface doses for several common diagnostic radiology procedure have been determined from exposure rate measurements and patient technique factors in seven 'World Health Imaging System - Radiography' (WHIS-RAD) units, installed in public health services facilities of the Republic of Haiti. The results show the entrance surface doses below the guidance levels published in the BSS. Concomitant image quality measurements performed, however, indicate serious artifacts in the film processing, calling for the need of additional training of the technologists. (author)

  3. A statistical correlation investigation for the role of surface spins to the spin relaxation of nitrogen vacancy centers

    Energy Technology Data Exchange (ETDEWEB)

    Song, Xuerui; Zhang, Jian; Feng, Fupan; Wang, Junfeng; Zhang, Wenlong; Lou, Liren; Zhu, Wei; Wang, Guanzhong, E-mail: gzwang@ustc.edu.cn [Hefei National Laboratory for Physical Science at Microscale, and Department of Physics, University of Science and Technology of China, Hefei, Anhui, 230026 (China)

    2014-04-15

    We investigated the influence of spins on surface of nanodiamonds (NDs) to the longitudinal relaxation time (T{sub 1}) and transverse relaxation time (T{sub 2}) of nitrogen vacancy (NV) centers in ND. A spherical model of the NDs was suggested to account for the experimental results of T{sub 1} and T{sub 2}, and the density of surface spins was roughly estimated based on the statistical analysis of experimental results of 72 NDs containing a single NV center. For NDs studied here, the T{sub 1} of NV center inside is highly dependent to the surface spins of the NDs. However, for the T{sub 2} of NV center, intrinsic contributions must be much pronounced than that by surface spins. In other words, T{sub 1} of an NV center in NDs is more sensitive to the change of the surface spin density than T{sub 2}.

  4. A statistical correlation investigation for the role of surface spins to the spin relaxation of nitrogen vacancy centers

    Directory of Open Access Journals (Sweden)

    Xuerui Song

    2014-04-01

    Full Text Available We investigated the influence of spins on surface of nanodiamonds (NDs to the longitudinal relaxation time (T1 and transverse relaxation time (T2 of nitrogen vacancy (NV centers in ND. A spherical model of the NDs was suggested to account for the experimental results of T1 and T2, and the density of surface spins was roughly estimated based on the statistical analysis of experimental results of 72 NDs containing a single NV center. For NDs studied here, the T1 of NV center inside is highly dependent to the surface spins of the NDs. However, for the T2 of NV center, intrinsic contributions must be much pronounced than that by surface spins. In other words, T1 of an NV center in NDs is more sensitive to the change of the surface spin density than T2.

  5. Ab initio investigation of the surface properties of austenitic Fe-Ni-Cr alloys in aqueous environments

    Energy Technology Data Exchange (ETDEWEB)

    Rák, Zs., E-mail: zrak@ncsu.edu; Brenner, D.W.

    2017-04-30

    Highlights: • The trend in the surface energies of austenitic stainless steels is: (111) < (100) < (110). • On the (111) orientation Ni segregates to the surface and Cr segregates into the bulk. • The surface stability of the alloys in contact with water decrease with temperature and pH. - Abstract: The surface energetics of two austenitic stainless steel alloys (Type 304 and 316) and three Ni-based alloys (Alloy 600, 690, and 800) are investigated using theoretical methods within the density functional theory. The relative stability of the low index surfaces display the same trend for all alloys; the most closely packed orientation and the most stable is the (111), followed by the (100) and the (110) surfaces. Calculations on the (111) surfaces using various surface chemical and magnetic configurations reveal that Ni has the tendency to segregate toward the surface and Cr has the tendency to segregate toward the bulk. The magnetic frustration present on the (111) surfaces plays an important role in the observed segregation tendencies of Ni and Cr. The stability of the (111) surfaces in contact with aqueous solution are evaluated as a function of temperature, pH, and concentration of aqueous species. The results indicate that the surface stability of the alloys decrease with temperature and pH, and increase slightly with concentration. Under conditions characteristic to an operating pressurized water reactor, the Ni-based alloy series appears to be of better quality than the stainless steel series with respect to corrosion resistance and release of aqueous species when in contact with aqueous solutions.

  6. Clinicians completion rate of radiology request card in a Nigerian ...

    African Journals Online (AJOL)

    The importance of adequately completing the radiology request card by the clinicians, in management of patient cannot be overemphasized. Omission of information on the request card may lead to reporting error. This study investigated the compliance rate of filling the radiology request card by clinicians received in a ...

  7. Ab initio investigation of the passivation effect of the acrylonitrile molecule on the Si(100)-(2 × 1) surface

    Energy Technology Data Exchange (ETDEWEB)

    Usanmaz, D., E-mail: demetusanmaz@gmail.com [Physics Program, Middle East Technical University, Northern Cyprus Campus, Kalkanlı, Güzelyurt, KKTC, Mersin 10 (Turkey); Srivastava, G.P. [School of Physics, University of Exeter, Stocker Road, Exeter EX4 4QL (United Kingdom)

    2014-08-17

    Highlights: • Different bonding configurations of acrylonitrile molecule on the Si(2 × 1) surface based on reported experimental results have been investigated. • The acrylonitrile molecule has the minimum energy configuration at the on-top adsorption site. • The adsorption of the acrylonitrile molecule passivates the Si(2 × 1) surface both chemically as well as electronically. • The resulting surface structure is passivated both chemically as well as electronically. - Abstract: Based on pseudopotentials and the density functional theory, we have investigated the atomic geometry and electronic structure of the acrylonitrile molecule adsorbed on the Si(100)-(2 × 1) surface. By considering different bonding configurations based on reported experimental results, we have investigated several possible geometries. Our total energy results suggest that the acrylonitrile molecule has the minimum energy configuration at the on-top adsorbtion site. The electronic surface properties of the most stable structure have been discussed. Our results show that the adsorption of this molecule fully passivates the Si(001)(2 × 1) surface.

  8. Modelling and investigation of partial wetting surfaces for drop dynamics using lattice Boltzmann method

    Science.gov (United States)

    Pravinraj, T.; Patrikar, Rajendra

    2017-07-01

    Partial wetting surfaces and its influence on the droplet movement of micro and nano scale being contemplated for many useful applications. The dynamics of the droplet usually analyzed with a multiphase lattice Boltzmann method (LBM). In this paper, the influence of partial wetting surface on the dynamics of droplet is systematically analyzed for various cases. Splitting of droplets due to chemical gradient of the surface is studied and analyses of splitting time for various widths of the strips for different Weber numbers are computed. With the proposed model one can tune the splitting volume and time by carefully choosing a strip width and droplet position. The droplet spreading on chemically heterogeneous surfaces shows that the spreading can be controlled not only by parameters of Weber number but also by tuning strip width ratio. The transportation of the droplet from hydrophobic surface to hydrophilic surface due to chemical gradient is simulated and analyzed using our hybrid thermodynamic-image processing technique. The results prove that with the progress of time the surface free energy decreases with increase in spreading area. Finally, the transportation of a droplet on microstructure gradient is demonstrated. The model explains the temporal behaviour of droplet during the spreading, recoiling and translation along with tracking of contact angle hysteresis phenomenon.

  9. Investigating the effect of surface water - groundwater interactions on stream temperature using Distributed temperature sensing and instream temperature model

    DEFF Research Database (Denmark)

    Karthikeyan, Matheswaran; Blemmer, Morten; Mortensen, Julie Flor

    2011-01-01

    Surface water–groundwater interactions at the stream interface influences, and at times controls the stream temperature, a critical water property driving biogeochemical processes. This study investigates the effects of these interactions on temperature of Stream Elverdamsåen in Denmark using...... the Distributed Temperature Sensing (DTS) system and instream temperature modelling. Locations of surface water–groundwater interactions were identified from the temperature data collected over a 2-km stream reach using a DTS system with 1-m spatial and 5-min temporal resolution. The stream under consideration...... surface water–groundwater interactions on heterogeneous behaviour of stream temperature....

  10. Experimental Investigation of Surface Wave Plasma Excited by a Cylindrical Dielectric Rod

    International Nuclear Information System (INIS)

    Wu Zhonghang; Li Zebin; He Kongduo; Yang Xilu; Chen Zhenliu; Ou Qiongrong; Liang Rongqing; Ju Jiaqi; Yan Hang

    2014-01-01

    An improved surface wave plasma source equipped with a cylindrical quartz rod has been developed, which has great potential in processing inner wall of cylindrical workpieces. A cylindrical quartz rod not only excites the plasma around the rod, but also guides surface wave plasma along the rod. The distributions of plasma density and plasma temperature under different incident microwave powers and pressures are diagnosed by a Langmuir probe. The electron density near the rod is around the order of 10 11 cm −3 . When the incident power is 450 W, the length of surface wave plasma column can reach up to 420 mm at 20 Pa. (low temperature plasma)

  11. Contrast investigations of surface acoustic waves by stroboscopic topography. 2. Wavefield deviation contrast

    Energy Technology Data Exchange (ETDEWEB)

    Cerva, H.; Graeff, W. (Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany, F.R.))

    1985-02-16

    When imaging a surface acoustic wave by stroboscopic X-ray topography a contrast contribution exists which can be related to the deviation of X-ray beams in the deformation field of the acoustic wave. With narrow entrance slits this contribution can be separated from the surface reflected waves. Using a beam path theory of Bonse the beam trajectories inside the crystal and the intensity profiles at the surface are calculated. It is also demonstrated that this contrast which has two nearly equal peaks within the acoustic period turns to the orientation contrast with one peak per period when increasing the distance between sample and film.

  12. Laboratory experiments to investigate radionuclide enrichment in the sea-surface microlayer

    International Nuclear Information System (INIS)

    Hickmott, S.J.B.

    1982-02-01

    Samples of simulated seawater, and seawater from the Irish Sea, were contained in a plastic tank in the laboratory, and bubbles were passed through them to burst at the water surface. The emitted jet droplets, as representing the surface microlayer, were collected on filter papers. Such measurements are easier to perform than similar measurements at sea, and the lack of waves enables greater collection efficiencies to be obtained. The droplet samples were analysed for stable Na, 137 Cs and actinides, and compared with the concentrations in the bulk tank water, in order to examine possible concentration factors for radionuclides in the surface microlayer. (author)

  13. 324 Building Baseline Radiological Characterization

    Energy Technology Data Exchange (ETDEWEB)

    R.J. Reeder, J.C. Cooper

    2010-06-24

    This report documents the analysis of radiological data collected as part of the characterization study performed in 1998. The study was performed to create a baseline of the radiological conditions in the 324 Building.

  14. Guidelines for a radiology department

    International Nuclear Information System (INIS)

    1981-05-01

    This manual presents guidelines for hospitals on a radiology quality assurance and dose measurement audit program and a system of planned actions that monitor and record the performance and effectiveness of the radiological service

  15. Radiological controls integrated into design

    Energy Technology Data Exchange (ETDEWEB)

    Kindred, G.W. [Cleveland Electric Illuminating Co., Perry, OH (United States)

    1995-03-01

    Radiological controls are required by law in the design of commercial nuclear power reactor facilities. These controls can be relatively minor or significant, relative to cost. To ensure that radiological controls are designed into a project, the health physicist (radiological engineer) must be involved from the beginning. This is especially true regarding keeping costs down. For every radiological engineer at a nuclear power plant there must be fifty engineers of other disciplines. The radiological engineer cannot be an expert on every discipline of engineering. However, he must be knowledgeable to the degree of how a design will impact the facility from a radiological perspective. This paper will address how to effectively perform radiological analyses with the goal of radiological controls integrated into the design package.

  16. Program of environmental radiological monitoring

    International Nuclear Information System (INIS)

    2005-11-01

    This Regulation refers to the requirement of the Regulation CNEN-NN.3.01, 'Basic Act of Radiological Protection', as expressed in the section 5.14, related to the Program of Environmental Radiological Monitoring (PMRA)

  17. American Society of Radiologic Technologists

    Science.gov (United States)

    ... Technology Job Bank Job Search Resources Radiologic Assistant Salary Estimator About ASRT Contact ASRT Membership Mission & Vision ... Now Open Nov 13, 2017 Libraries in New Mexico Recognize National Radiologic Technology Week® Nov 07, 2017 ...

  18. Investigation of Corrosion and Cathodic Protection in Reinforced Concrete. II : Properties of Steel Surface Layers

    NARCIS (Netherlands)

    Koleva, D.A.; De Wit, J.H.W.; Van Breugel, K.; Lodhi, Z.F.; Ye, G.

    2007-01-01

    The present study explores the formation of corrosion products on the steel surface (using as-received low carbon construction steel) in reinforced concrete in conditions of corrosion and subsequent transformation of these layers in conditions of cathodic protection (CP).

  19. Investigating the cellular specificity in tumors of a surface converting nanoparticle by multimodal imaging

    NARCIS (Netherlands)

    Fay, Francois; Hansen, Line; Hectors, Stefanie J C G; Sanchez-Gaytan, Brenda L; Zhao, Yiming; Tang, Jun; Munitz, Jazz; Alaarg, Amr; Braza, Mounia S; Gianella, Anita; Aaronson, Stuart A; Reiner, Thomas; Kjems, Jørgen; Langer, Robert; Hoeben, Freek J M; Janssen, Henk M; Calcagno, Claudia; Strijkers, Gustav J; Fayad, Zahi A; Perez-Medina, Carlos; Mulder, Willem J M

    2017-01-01

    Active targeting of nanoparticles through surface functionalization is a common strategy to enhance tumor delivery specificity. However, active targeting strategies tend to work against long polyethylene glycol's shielding effectiveness and associated favorable pharmacokinetics. To overcome these

  20. Investigating the Cellular Specificity in Tumors of a Surface-Converting Nanoparticle by Multimodal Imaging

    NARCIS (Netherlands)

    Fay, Francois; Hansen, Line; Hectors, Stefanie J. C. G.; Sanchez-Gaytan, Brenda L.; Zhao, Yiming; Tang, Jun; Munitz, Jazz; Alaarg, Amr; Braza, Mounia S.; Gianella, Anita; Aaronson, Stuart A.; Reiner, Thomas; Kjems, Jurgen; Langer, Robert; Hoeben, Freek J. M.; Janssen, Henk M.; Calcagno, Claudia; Strijkers, Gustav J.; Fayad, Zahi A.; Perez-Medina, Carlos; Mulder, Willem J. M.

    2017-01-01

    Active targeting of nanoparticles through surface functionalization is a common strategy to enhance tumor delivery specificity. However, active targeting strategies tend to work against long polyethylene glycol's shielding effectiveness and associated favorable pharmacokinetics. To overcome these

  1. Chromate Adsorption on Selected Soil Minerals: Surface Complexation Modeling Coupled with Spectroscopic Investigation.

    Czech Academy of Sciences Publication Activity Database

    Veselská, V.; Fajgar, Radek; Číhalová, S.; Bolanz, R.M.; Göttlicher, J.; Steininger, R.; Siddique, J.A.; Komárek, M.

    2016-01-01

    Roč. 318, NOV 15 (2016), s. 433-442 ISSN 0304-3894 Institutional support: RVO:67985858 Keywords : surface complexation modeling * chromate * soil minerals Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 6.065, year: 2016

  2. An Investigation of Surface Current Patterns Related to Upwelling in Monterey Bay, Using High Frequency Radar

    National Research Council Canada - National Science Library

    Enriquez, Andres

    2004-01-01

    High Frequency (HF) radar backscatter instruments are under development and testing in the marine science and defense science communities for their abilities to remotely sense surface parameters in the coastal ocean over large areas...

  3. Investigation of Plasma Etching for Superconducting RF Cavities Surface Preparation. Final Report

    International Nuclear Information System (INIS)

    Vuskovic, Leposava

    2009-01-01

    Our results show that plasma-treated samples are comparable or superior to a BCP sample, both in the size of features and sharpness of the boundaries between individual features at the surface. Plasma treatment of bulk Nb cavities is a promising technique for microwave cavities preparation used in particle acceleration application. Etching rates are sufficiently high to enable efficient removal of mechanically damaged surface layer with high reproducibility. No impurities are deposited on the bulk Nb surface during plasma treatment. Surface topology characteristic are promising for complex cavity geometry, since discharge conforms the profile of the reaction chamber. In view of these experimental results, we propose plasma treatment for producing microwave cavities with high Q factor instead of using bulk Nb treated with wet etching process.

  4. PHYSICOCHEMICAL AND STRUCTURAL INVESTIGATION OF THE SURFACES OF SOME ANAEROBIC SUBGINGIVAL BACTERIA

    NARCIS (Netherlands)

    COWAN, MM; VANDERMEI, HC; ROUXHET, PG; BUSSCHER, HJ

    The surfaces of nine clinical isolates of Porphyromonas gingivalis, Prevotella intermedia, Actinobacillus actinomycetemcomitans, and Peptostreptococcus micros and that of laboratory strain P. gingivalis W83 were studied by using contact angle measurements, X-ray photoelectron spectroscopy, infrared

  5. Mass spectrometric investigation of synthetic glycoside of muramyl dipeptide immobilized on fumed silica surface

    International Nuclear Information System (INIS)

    Kulik, Tetiana V.; Azizova, Liana R.; Palyanytsya, Borys B.; Zemlyakov, Alexander E.; Tsikalova, Victoria N.

    2010-01-01

    N-Acetylmuramyl-L-alanyl-D-isoglutamine or muramyl dipeptide is a cleavage product of peptidoglycan by lysozyme. This study explored the use of the temperature-programmed desorption mass spectrometry (TPDMS) in analysis of glycoside of muramyl dipeptide: O-{(4-tert-butylcyclohexyl)-2-acetamido-2, 3-dideoxy-β-D-glucopyranoside-3-yl}-D-lactoyl-L-alanyl-D-isoglutamine (MDP) on the surface of fumed silica. Stages of pyrolysis of MDP in condensed state and on the silica surface have been determined. Three stages have been clear identified under pyrolysis of MDP on the silica surface. Kinetic parameters of thermal reactions on the fumed silica surface and in the condensed state have been calculated.

  6. Combining Surface Analytical and Computational Techniques to Investigate Orientation Effects of Immobilized Proteins

    Science.gov (United States)

    Harrison, Elisa Turla

    Controlling how proteins are immobilized (e.g. controlling their orientation and conformation) is essential for developing and optimizing the performance of in vitro protein-binding devices, such as enzyme-linked immunosorbent assays. The objective of this work is to develop new methodologies to study proteins and complex mixtures of proteins immobilized onto surfaces. The focus of this study was to control and characterize the orientation of protein G B1, an IgG antibody-binding domain of protein G, on well-defined surfaces as well as measure the effect of protein G B1 orientation on IgG antibody binding using a variety of surface analytical and computational techniques. The surface sensitivity of time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to distinguish between different proteins and their orientation by monitoring the changes in intensity of characteristic amino acid mass fragments. Amino acids distributed asymmetrically were used to calculate peak intensity ratios from ToF-SIMS data to determine the orientation of five different cysteine mutants of protein G B1 covalently attached to a maleimide surface. To study the effect of protein orientation on antibody binding, we formed multilayer protein films by binding IgG to protein G B1 films. Quartz crystal microbalance with dissipation monitoring (QCM-D) detected protein coverages of 69-130 ng/cm2 (theoretical mass of a monolayer of protein G B1 is 110-160 ng/cm2). QCM-D and X-ray photoelectron spectroscopy analysis revealed that packing density along with orientation affected the antibody binding process. Spectra from ToF-SIMS using large Ar gas cluster ion sources distinguished between different proteins in multilayer protein systems. A Monte Carlo algorithm was developed to predict protein orientation on surfaces. Two distinct orientations of protein G B1 adsorbed onto a hydrophobic surface were found and characterized as two mutually exclusive sets of amino acids on the outermost

  7. Controlled source radiomagnetotellurics: A tool for near surface investigations in remote regions

    Science.gov (United States)

    Saraev, Alexander; Simakov, Alexander; Shlykov, Arseny; Tezkan, Bülent

    2017-11-01

    In the course of near surface measurements, we investigated the application of the controlled source radiomagnetotelluric (CSRMT) sounding method. The used equipment RMT-C includes a five-channel recorder (frequency range 1-1000 kHz), two electric and three magnetic sensors, and a transmitter (1 kW) with a horizontal electric dipole as a source. The electric field measurements are carried out with ungrounded lines thus enabling surveys in the wintertime on snow and ice, and in the summertime in conditions adverse to the groundings. The use of electric dipole as a source ensures operating in a wide frequency range at a significant distance (up to 3-4 km) from the source. Measurements of basic signals and their odd sub harmonics raise the efficiency of the field surveys. For the covering of the full frequency range 1-1000 kHz, three basic frequencies are usually transmitted; each one is accompanied by 8-12 sub harmonics. This provides a high rate of measurements, i.e. about 70 sounding stations per day - 10 times faster than by the vertical electric sounding (VES) method. The CSRMT method offers the possibility to work in the far-field zone of the controlled source where the plane wave approximation of the primary field can be used. For the analysis of the high-frequency field of the electric dipole, an approach is used considering quasi-stationary and wave zones of the source. Features of the electromagnetic field are analyzed by taking into account displacement currents in the air. In the wave zone, at a certain distance from the source (tens to hundreds of meters), field components are characterized by a number of differences compared to a quasi-stationary zone (slower drop of the field's amplitudes, change of the directional diagram of the source, appearance of the ellipticity of polarization of electric and magnetic fields). The CSRMT method is intended for the application in remote regions where surveys by the standard RMT method could only use Very Low

  8. Investigating Land Surface Phenology Derived from Satellite and GPS Network Microwave Remote Sensing

    Science.gov (United States)

    Jones, M. O.; Kimball, J. S.; Small, E. E.; Larson, K. M.

    2013-12-01

    The land surface phenology (LSP) start of season (SOS) metric signals the seasonal onset of vegetation activity, including canopy growth and associated increases in land-atmosphere water, energy and carbon (CO2) exchanges influencing weather and climate variability. The Vegetation Optical Depth (VOD) parameter determined from satellite passive microwave remote sensing provides for global LSP monitoring that is sensitive to changes in vegetation canopy water content and biomass, and insensitive to atmosphere and solar illumination constraints. Direct field measures of canopy water content and biomass changes desired for LSP validation are generally lacking due to prohibitive costs of maintaining regional monitoring networks. Alternatively, a Normalized Microwave Reflectance Index (NMRI) derived from GPS base station measurements is sensitive to daily vegetation water content changes and may provide for effective microwave LSP validation as a relatively high spatial (1000m2) and temporal resolution vegetation phenology measure. We compared NMRI (1.2 and 1.5 GHz) and satellite microwave (AMSR-E sensor) 18.7 GHz frequency VOD records (2007 to 2011) at over 300 GPS sites in North America and their derived SOS metrics for a subset of 24 homogenous land cover sites. Significant correlations were found at 276 of 305 sites, with generally favorable correspondence in the resulting SOS metrics. We also investigated the temporal dynamics of nine NMRI sites within a single 25km resolution VOD pixel and with corresponding 250m MODIS NDVI measures of the three dominant land covers within the pixel to assess the spatial scale discrepancies between these high, moderate, and coarse resolution retrievals. This study is the first attempt to compare satellite microwave LSP metrics to a GPS network derived reflectance index and highlights both the utility and limitations of the NMRI data for LSP validation. Integration of GPS base stations and the NMRI into current phenology observation

  9. Surface wave investigations of Se amorphous thin films deposited on LiNbO/sub 3/

    Energy Technology Data Exchange (ETDEWEB)

    Kostial, P. (Technical University of Transport and Communication Engineering, Zilina (Czechoslovakia). Dept. of Physics)

    1982-03-16

    A study is presented of the temperature dependence between 300 and 350 K of the ultrasound attenuation and velocity of Rayleigh surface waves propagating in Se amorphous layers deposited on Y-cut LiNbO/sub 3/. The possibility of utilization of Rayleigh surface waves for the study of visco-elastic properties of thin layers deposited on a piezoelectric substrate is discussed.

  10. Investigation of multi-scale flash-weakening of rock surfaces during high speed slip

    Science.gov (United States)

    Barbery, M. R.; Saber, O.; Chester, F. M.; Chester, J. S.

    2017-12-01

    A significant reduction in the coefficient of friction of rock can occur if sliding velocity approaches seismic rates as a consequence of weakening of microscopic sliding contacts by flash heating. Using a high-acceleration and -speed biaxial apparatus equipped with a high-speed Infra-Red (IR) camera to capture thermographs of the sliding surface, we have documented the heterogeneous distribution of temperature on flash-heated decimetric surfaces characterized by linear arrays of high-temperature, mm-size spots, and streaks. Numerical models that are informed by the character of flash heated surfaces and that consider the coupling of changes in temperature and changes in the friction of contacts, supports the hypothesis that independent mechanisms of flash weakening operate at different contact scales. Here, we report on new experiments that provide additional constraints on the life-times and rest-times of populations of millimeter-scale contacts. Rock friction experiments conducted on Westerly granite samples in a double-direct shear configuration achieve velocity steps from 1 mm/s to 900 mm/s at 100g accelerations over 2 mm of displacement with normal stresses of 22-36 MPa and 30 mm of displacement during sustained high-speed sliding. Sliding surfaces are machined to roughness similar to natural fault surfaces and that allow us to control the characteristics of millimeter-scale contact populations. Thermographs of the sliding surface show temperatures up to 200 C on millimeter-scale contacts, in agreement with 1-D heat conduction model estimates of 180 C. Preliminary comparison of thermal modeling results and experiment observations demonstrate that we can distinguish the different life-times and rest-times of contacts in thermographs and the corresponding frictional weakening behaviors. Continued work on machined surfaces that lead to different contact population characteristics will be used to test the multi-scale and multi-mechanism hypothesis for flash

  11. The Investigation of the Cavitation Phenomenon in the Laval Nozzle with Full and Partial Surface Wetting

    Directory of Open Access Journals (Sweden)

    Jablonská Jana

    2017-04-01

    Full Text Available The article deals with the cavitation phenomenon affected by full and partial wetting of the wall. For the numerical computation of flow in the Laval nozzle the Schnerr-Sauer cavitation model was tested and was used for cavitation research of flow within the nozzle considering partial surface wetting. The coefficient of wetting for various materials was determined using experimental, theoretical and numerical methods of fluid flow due to partial surface wetting.

  12. Investigation of sandwich material surface created by abrasive water jet (AWJ via vibration emission

    Directory of Open Access Journals (Sweden)

    P. Hreha

    2014-01-01

    Full Text Available The paper presents research a of abrasive waterjet cutting of heterogeneous “sandwich“ material with different Young modulus of elasticity of the cutted surface geometry by means of vibration emission. In order to confirm hypothetical assumptions about direct relation between vibration emission and surface quality an experiment in heterogeneous material consisting of stainless steel (DIN 1.4006 / AISI 410 and alloy AlCuMg2 has been provided.

  13. Investigation on surface structure of potassium permanganate/nitric acid treated poly(tetrafluoroethylene)

    International Nuclear Information System (INIS)

    Fu, Congli; Liu, Shuling; Gong, Tianlong; Gu, Aiqun; Yu, Zili

    2014-01-01

    Highlights: • A new transformation (conversion) mechanism of PTFE surface from a hydrophobicity to a hydrophilicity was proposed through the treatment of KMnO 4 /HNO 3 . • Chemical reactions or defluorination of PTFE described in the reported paper was testified to be a misconceived conclusion by the combination of several testing measurements (IR, XPS, XRD and so on) in our present work. • Deposition of manganese oxide and/or manganese hydroxide on PTFE surface contributed to the hydrophilic property of the modified PTFE with KMnO 4 /HNO 3 treated. • The deposition thickness on the modified PTFE surface was about 5 μm, which was significantly helpful in enhancing the adhesive strength of PTFE with other materials. - Abstract: In the previous articles concerning the treatment of poly(tetrafluoroethylene) (PTFE) with potassium permanganate/nitric acid mixture, the conversion of a hydrophobic to a hydrophilic surface was partially assigned to the defluorination of PTFE and then the introduction of carbonyl and hydroxyl groups into the defluorinated sites. In the present work, PTFE sheets were treated with potassium permanganate/nitric acid, and the surfaces before and after treatment were comparatively characterized by Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD) and scanning electron microscopy (SEM). The surface sediments of the treated PTFE were also determined by atomic absorption spectroscopy (AAS). The results indicate that the conversion of the hydrophobicity to the hydrophilicity on the modified PTFE surface is mainly due to the deposition of hydrophilic manganese oxides which covered the fluorocarbon surface, and no detectable chemical reactions of PTFE occur in the treating process

  14. A preliminary investigation of the Topaz II reactor as a lunar surface power supply

    International Nuclear Information System (INIS)

    Polansky, G.F.; Houts, M.G.

    1995-01-01

    Reactor power supplies offer many attractive characteristics for lunar surface applications. The Topaz II reactor resulted from an extensive development program in the former Soviet Union. Flight quality reactor units remain from this program and are currently under evaluation in the United States. This paper examines the potential for applying the Topaz II, originally developed to provide spacecraft power, as a lunar surface power supply

  15. A preliminary investigation of the Topaz II reactor as a lunar surface power supply

    Energy Technology Data Exchange (ETDEWEB)

    Polansky, G.F. [Sandia National Labs., Albuquerque, NM (United States); Houts, M.G. [Los Alamos National Lab., NM (United States)

    1995-12-31

    Reactor power supplies offer many attractive characteristics for lunar surface applications. The Topaz II reactor resulted from an extensive development program in the former Soviet Union. Flight quality reactor units remain from this program and are currently under evaluation in the United States. This paper examines the potential for applying the Topaz II, originally developed to provide spacecraft power, as a lunar surface power supply.

  16. Investigation of the Cell Surface Proteome of Human Periodontal Ligament Stem Cells

    OpenAIRE

    Xiong, Jimin; Menicanin, Danijela; Zilm, Peter S.; Marino, Victor; Bartold, P. Mark; Gronthos, Stan

    2016-01-01

    The present study examined the cell surface proteome of human periodontal ligament stem cells (PDLSC) compared to human fibroblasts. Cell surface proteins were prelabelled with CyDye before processing to extract the membrane lysates, which were separated using 2D electrophoresis. Selected differentially expressed protein ?spots? were identified using Mass spectrometry. Four proteins were selected for validation: CD73, CD90, Annexin A2, and sphingosine kinase 1 previously associated with mesen...

  17. Imaging and radiology

    Science.gov (United States)

    ... how well your body is responding to a treatment you are receiving for your disease or condition Screen for different illnesses, such as breast cancer, colon cancer, or heart disease The most common types of diagnostic radiology exams include: Computed tomography (CT), also known ...

  18. German radiological congress 1983

    International Nuclear Information System (INIS)

    Haubitz, B.; Stender, H.S.

    1983-01-01

    The publication contains the abstracts of the 261 papers read at the meeting and the 82 further papers announced, and 37 brief descriptions of the contributions to the scientific exhibition. The papers were on the subjects of radiology, nuclear medicine and to a certain extent, also radiobiology. (MG) [de

  19. Radiologic Career Ladder

    Science.gov (United States)

    1992-09-01

    of operating fixed and mobile radiologic equipment; routine and special radiographic positioning; theory and practice of special radiographic...defined as training provided by resident technical schools, field training detachments (FTD), mobile training teams (MTT), formal OJT, or any other...TISSUE STUDIES 81 1316 PERFORM HUMERUS RADIOGRAPHIC EXAMINATIONS 81 1306 PERFORM COCCYX RADIOGRAPHIC EXAMINATIONS 81 1329 PERFORM PARANASAL SINUS

  20. SA Journal of Radiology

    African Journals Online (AJOL)

    Radiology examination as a diagnostic aid in presentations with wide differential diagnoses: Case report of new Hodgkin's lymphoma on a background of poorly controlled HIV · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. Rachel Hubbard, Jalpa Kotecha, Thomas ...