WorldWideScience

Sample records for surface light source

  1. Surface Emitting, High Efficiency Near-Vacuum Ultraviolet Light Source with Aluminum Nitride Nanowires Monolithically Grown on Silicon.

    Science.gov (United States)

    Zhao, S; Djavid, M; Mi, Z

    2015-10-14

    To date, it has remained challenging to realize electrically injected light sources in the vacuum ultraviolet wavelength range (∼200 nm or shorter), which are important for a broad range of applications, including sensing, surface treatment, and photochemical analysis. In this Letter, we have demonstrated such a light source with molecular beam epitaxially grown aluminum nitride (AlN) nanowires on low cost, large area Si substrate. Detailed angle dependent electroluminescence studies suggest that, albeit the light is TM polarized, the dominant light emission direction is from the nanowire top surface, that is, along the c axis, due to the strong light scattering effect. Such an efficient surface emitting device was not previously possible using conventional c-plane AlN planar structures. The AlN nanowire LEDs exhibit an extremely large electrical efficiency (>85%), which is nearly ten times higher than the previously reported AlN planar devices. Our detailed studies further suggest that the performance of AlN nanowire LEDs is predominantly limited by electron overflow. This study provides important insight on the fundamental emission characteristics of AlN nanowire LEDs and also offers a viable path to realize an efficient surface emitting near-vacuum ultraviolet light source through direct electrical injection.

  2. Advanced Light Source (ALS)

    Data.gov (United States)

    Federal Laboratory Consortium — The Advanced Light Source (ALS), a world leader in soft x-ray science, generates light in the wavelengths needed for examining the atomic and electronic structure of...

  3. Photonic crystal light source

    Science.gov (United States)

    Fleming, James G [Albuquerque, NM; Lin, Shawn-Yu [Albuquerque, NM; Bur, James A [Corrales, NM

    2004-07-27

    A light source is provided by a photonic crystal having an enhanced photonic density-of-states over a band of frequencies and wherein at least one of the dielectric materials of the photonic crystal has a complex dielectric constant, thereby producing enhanced light emission at the band of frequencies when the photonic crystal is heated. The dielectric material can be a metal, such as tungsten. The spectral properties of the light source can be easily tuned by modification of the photonic crystal structure and materials. The photonic crystal light source can be heated electrically or other heating means. The light source can further include additional photonic crystals that exhibit enhanced light emission at a different band of frequencies to provide for color mixing. The photonic crystal light source may have applications in optical telecommunications, information displays, energy conversion, sensors, and other optical applications.

  4. Light Sources and Lighting Circuits

    Science.gov (United States)

    Honda, Hisashi; Suwa, Takumi; Yasuda, Takeo; Ohtani, Yoshihiko; Maehara, Akiyoshi; Okada, Atsunori; Komatsu, Naoki; Mannami, Tomoaki

    According to the Machinery Statistics of the Ministry of Economy, Trade and Industry, the production of incandescent lamps in Japan in 2007 was 990 million units (90.0% of the previous year's total), in which the production of incandescent lamps for general lighting was 110 million units (90.0% of the previous year's total) and of tungsten-halogen lamps was 44 million units (96.6% of the previous year's total). The production of fluorescent lamps was 927 million units (93.9% of the previous year's total), in which general fluorescent lamps, excluding those for LCD back lighting, was 320 million units (87.2% of the previous year's total). Also, the production of HID lamps was 10 million units (101.5% of the previous year's total). On the other hand, when the numbers of sales are compared with the sales of the previous year, incandescent lamps for general use was 99.8%, tungsten-halogen lamps was 96.9%, fluorescent lamps was 95.9%, and HID lamps was 98.9%. Self-ballasted fluorescent lamps alone showed an increase in sales as strong as 29 million units, or 121.7% of the previous year's sales. It is considered that the switchover of incandescent lamps to HID lamps was promoted for energy conservation and carbon dioxide reduction with the problem of global warming in the background. In regard to exhibitions, Lighting Fair 2007 was held in Tokyo in March, and LIGHTFAIR INTERNATIONAL 2007 was held in New York in May. Regarding academic conferences, LS:11 (the 11th International Symposium on the Science & Technology of Light Sources) was held in Shanghai in May, and the First International Conference on White LEDs and Solid State Lighting was held in Tokyo in November. Both conferences suggested that there are strong needs and concerns now about energy conservation, saving natural resources, and restrictions of hazardous materials. In regard to incandescent lamps, the development of products aiming at higher efficacy, electric power savings, and longer life was advanced by

  5. National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Hulbert, S.L.; Lazarz, N.M.

    1991-04-01

    This report discussion research being conducted at the National Synchrotron light source. In particular, this report contains operations summaries; symposia, workshops, and projects; NSLS highlights; and abstracts of science at the NSLS

  6. Food contact surfaces coated with nitrogen-doped titanium dioxide: effect on Listeria monocytogenes survival under different light sources

    International Nuclear Information System (INIS)

    Rodrigues, D.; Teixeira, P.; Tavares, C.J.; Azeredo, J.

    2013-01-01

    Improvement of food safety is a very important issue, and is on the basis of production and application of new/modified food contact surfaces. Titanium dioxide (TiO 2 ) and, more recently, nitrogen-doped titanium dioxide (N-TiO 2 ) coatings are among the possible forms to enhance food contact surfaces performance in terms of higher hygiene and easier sanitation. In this context, the present work aimed at evaluating the bactericidal activity of an N-TiO 2 coating on glass and stainless steel under two different sources of visible light – fluorescent and incandescent – and ultraviolet (UV) irradiation. Listeria monocytogenes was chosen as representative of major foodborne pathogens and its survival was tested on N-TiO 2 coated coupons. In terms of survival percentage, good results were obtained after exposure of coated surfaces to all light types since, apart from the value obtained after exposing glass to fluorescent light (56.3%), survival rates were always below 50%. However, no effective disinfection was obtained, given that for a disinfectant or sanitizing agent to be claimed as effective it needs to be able to promote at least a 3-log reduction of the microbial load, which was not observed for any of the experimental conditions assessed. Even so, UV irradiation was the most successful on eliminating cells on coated surfaces, since the amount of bacteria was reduced to 1.49 × 10 6 CFU/ml on glass and 2.37 × 10 7 on stainless steel. In contrast, both visible light sources had only slightly decreased the amount of viable cells, which remained in the range of 8 log CFU/ml. Hence, although some bactericidal effect was accomplished under visible light, UV was the most effective light source on promoting photocatalytic reactions on N-TiO 2 coated coupons and none of the experimental conditions have reached a satisfactory disinfection level. Thus, this surface coating needs further research and improvement in order to become truly effective against foodborne

  7. Food contact surfaces coated with nitrogen-doped titanium dioxide: effect on Listeria monocytogenes survival under different light sources

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, D.; Teixeira, P. [Institute for Biotechnology and Bioengineering, Centre of Biological Engineering, University of Minho, Campus de Gualtar, 4710-057 Braga (Portugal); Tavares, C.J. [Center of Physics, University of Minho, Campus de Azurém, 4800-058 Guimarães (Portugal); Azeredo, J., E-mail: jazeredo@deb.uminho.pt [Institute for Biotechnology and Bioengineering, Centre of Biological Engineering, University of Minho, Campus de Gualtar, 4710-057 Braga (Portugal)

    2013-04-01

    Improvement of food safety is a very important issue, and is on the basis of production and application of new/modified food contact surfaces. Titanium dioxide (TiO{sub 2}) and, more recently, nitrogen-doped titanium dioxide (N-TiO{sub 2}) coatings are among the possible forms to enhance food contact surfaces performance in terms of higher hygiene and easier sanitation. In this context, the present work aimed at evaluating the bactericidal activity of an N-TiO{sub 2} coating on glass and stainless steel under two different sources of visible light – fluorescent and incandescent – and ultraviolet (UV) irradiation. Listeria monocytogenes was chosen as representative of major foodborne pathogens and its survival was tested on N-TiO{sub 2} coated coupons. In terms of survival percentage, good results were obtained after exposure of coated surfaces to all light types since, apart from the value obtained after exposing glass to fluorescent light (56.3%), survival rates were always below 50%. However, no effective disinfection was obtained, given that for a disinfectant or sanitizing agent to be claimed as effective it needs to be able to promote at least a 3-log reduction of the microbial load, which was not observed for any of the experimental conditions assessed. Even so, UV irradiation was the most successful on eliminating cells on coated surfaces, since the amount of bacteria was reduced to 1.49 × 10{sup 6} CFU/ml on glass and 2.37 × 10{sup 7} on stainless steel. In contrast, both visible light sources had only slightly decreased the amount of viable cells, which remained in the range of 8 log CFU/ml. Hence, although some bactericidal effect was accomplished under visible light, UV was the most effective light source on promoting photocatalytic reactions on N-TiO{sub 2} coated coupons and none of the experimental conditions have reached a satisfactory disinfection level. Thus, this surface coating needs further research and improvement in order to become truly

  8. Enhanced Light Output of Dipole Source in GaN-Based Nanorod Light-Emitting Diodes by Silver Localized Surface Plasmon

    Directory of Open Access Journals (Sweden)

    Huamao Huang

    2014-01-01

    Full Text Available The light output of dipole source in three types of light-emitting diodes (LEDs, including the conventional planar LED, the nanorod LED, and the localized surface plasmon (LSP assisted LED by inserting silver nanoparticles in the gaps between nanorods, was studied by use of two-dimensional finite difference time domain method. The height of nanorod and the size of silver nanoparticles were variables for discussion. Simulation results show that a large height of nanorod induces strong wavelength selectivity, which can be significantly enhanced by LSP. On condition that the height of nanorod is 400 nm, the diameter of silver nanoparticle is 100 nm, and the wavelength is 402.7 nm, the light-output efficiency for LSP assisted LED is enhanced by 190% or 541% as compared to the nanorod counterpart or the planar counterpart, respectively. The space distribution of Poynting vector was present to demonstrate the significant enhancement of light output at the resonant wavelength of LSP.

  9. High-directional light source using photon recycling with a retro-reflective Dome incorporated with a textured LED die surface.

    Science.gov (United States)

    Sun, Ching-Cherng; Chung, Shuang-Chao; Yang, Shuang-Hao; Yu, Yeh-Wei; Chien, Wei-Ting; Chen, Huang-Kuen; Chen, Shih-Peng

    2013-07-29

    This paper demonstrates a novel retro-reflective dome that enhances the directionality of a light emitting diode (LED) by recycling photons reflected by a textured LED die surface. A simulation model is developed to describe both the photon recycling process within the dome and the role of specific pyramid patterns on the top surface of the LED die. Advanced simulations showed that a perfectly polished surface with 100% reflectivity potentially enhances the directionality of the dome by 340%, 250%, and 240% using reflective domes with 10°, 20°, and 30° light cones, respectively. In the experiment, the directionality of the domes exhibiting surface imperfections is enhanced by approximately 160%, 150%, and 130% using 10°, 20°, and 30° light cones, respectively. By incorporating a textured top surface on the LED die, the proposed dome effectively increases the directionality of the LED light source.

  10. Swiss Light Source SLS

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-09-01

    The Paul Scherrer Institute has begun work on the implementation of the Swiss Synchrotron Light Source (SLS). The construction of this facility, which will have international scope, is intended to provide a national focus for co-operation between various disciplines and for research in material sciences. Although basic research in physics and chemistry, biology, medicine and environmental sciences would seem to be in the foreground, industrial users also have an interest in the SLS. At present, this mainly centres on investigations into the structure of biological and chemical molecules, the use of high-performance methods of analysis, and the manufacture and investigation of microstructures. SLS is planned to be taken into service with an initial experimental installation by the middle of 2001. In this brochure an overview is presented on the main characteristics of the SLS facility and on its significance as a tool for interdisciplinary research.

  11. Swiss Light Source SLS

    International Nuclear Information System (INIS)

    1999-09-01

    The Paul Scherrer Institute has begun work on the implementation of the Swiss Synchrotron Light Source (SLS). The construction of this facility, which will have international scope, is intended to provide a national focus for co-operation between various disciplines and for research in material sciences. Although basic research in physics and chemistry, biology, medicine and environmental sciences would seem to be in the foreground, industrial users also have an interest in the SLS. At present, this mainly centres on investigations into the structure of biological and chemical molecules, the use of high-performance methods of analysis, and the manufacture and investigation of microstructures. SLS is planned to be taken into service with an initial experimental installation by the middle of 2001. In this brochure an overview is presented on the main characteristics of the SLS facility and on its significance as a tool for interdisciplinary research

  12. The effects of Exposure Times and Light Curing Sources on Surface Micro-Hardness of a Resin Modified Glass Ionomer

    Directory of Open Access Journals (Sweden)

    Iman Parisay

    2014-06-01

    Full Text Available Introduction: The aim of this study was to evaluate the influenceof different light curing systems and curing times on the micro-hardness of aresin modified glass ionomer. Methods: Forty two samples of ResinModified Glass Ionomer (RMGI were prepared using stainless steel cylindrical mold(8 × 2 mm and randomly divided into six groups of seven. Three groups werecured with a Quartz Tungsten Halogen (QTH light cure unit and the other threegroups were polymerized with LED unit for 20, 30 and 40 seconds. All sampleswere stored in distilled water for 24 hours. The micro-hardness was measured onthe top and bottom surfaces of the samples by Vickers hardness tester. Datawere analyzed by two–way ANOVA and Tukey’s post-hoc tests. Results: Two-wayANOVA showed that QTH light-cure unit had higher percentage in depth of curethan LED light-curing unit in both surfaces; whereas, the application time hasno significant effect on it. There was no interaction between two variables. Inboth light-curing groups, the values of top and bottom surfaces micro-hardnesswere increased as the application time increased, but there was not anystatistically significant difference among these groups except for 40-second groupof LED light-curing unit which was significantly higher than 20-second and30-second groups (P

  13. Light extraction block with curved surface

    Science.gov (United States)

    Levermore, Peter; Krall, Emory; Silvernail, Jeffrey; Rajan, Kamala; Brown, Julia J.

    2016-03-22

    Light extraction blocks, and OLED lighting panels using light extraction blocks, are described, in which the light extraction blocks include various curved shapes that provide improved light extraction properties compared to parallel emissive surface, and a thinner form factor and better light extraction than a hemisphere. Lighting systems described herein may include a light source with an OLED panel. A light extraction block with a three-dimensional light emitting surface may be optically coupled to the light source. The three-dimensional light emitting surface of the block may includes a substantially curved surface, with further characteristics related to the curvature of the surface at given points. A first radius of curvature corresponding to a maximum principal curvature k.sub.1 at a point p on the substantially curved surface may be greater than a maximum height of the light extraction block. A maximum height of the light extraction block may be less than 50% of a maximum width of the light extraction block. Surfaces with cross sections made up of line segments and inflection points may also be fit to approximated curves for calculating the radius of curvature.

  14. Intermediate-energy light sources

    CERN Document Server

    Corbett, W

    2003-01-01

    Increasingly, atomic scale information underlies scientific and technological progress in disciplines ranging from pharmaceutical development to materials synthesis to environmental remediation. While a variety of research tools are used to provide atomic scale information, synchrotron radiation has proved invaluable in this quest. The rapid growth of soft- and hard X-ray synchrotron light sources stands as stark testimony to the importance and utility of synchrotron radiation. Starting from just a handful of synchrotron light sources in the early 1970s, this burgeoning field now includes over 70 proposed, in-construction, or operating facilities in 23 countries on five continents. Along the way, synchrotron light facilities have evolved from small laboratories extracting light parasitically from storage rings designed for high-energy physics research to large, dedicated sources using the latest technology to produce extraordinarily bright photon beams. The basic layout of a multi-GeV storage ring light sourc...

  15. The Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    White, William E., E-mail: wewhite@slac.stanford.edu; Robert, Aymeric; Dunne, Mike [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2015-04-21

    The present status of the Linac Coherent Light Source as a user facility is presented. Opportunities and challenges as well as the scientific impact of X-ray free-electron lasers are discussed. The Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory was the first hard X-ray free-electron laser (FEL) to operate as a user facility. After five years of operation, LCLS is now a mature FEL user facility. Our personal views about opportunities and challenges inherent to these unique light sources are discussed.

  16. Flicker Vision of Selected Light Sources

    Science.gov (United States)

    Otomański, Przemysław; Wiczyński, Grzegorz; Zając, Bartosz

    2017-10-01

    The results of the laboratory research concerning a dependence of flicker vision on voltage fluctuations are presented in the paper. The research was realized on a designed measuring stand, which included an examined light source, a voltage generator with amplitude modulation supplying the light source and a positioning system of the observer with respect to the observed surface. In this research, the following light sources were used: one incandescent lamp and four LED luminaires by different producers. The research results formulate a conclusion concerning the description of the influence of voltage fluctuations on flicker viewing for selected light sources. The research results indicate that LED luminaires are less susceptible to voltage fluctuations than incandescent bulbs and that flicker vision strongly depends on the type of LED source.

  17. Compact synchrotron light sources

    CERN Document Server

    Weihreter, Ernst

    1996-01-01

    This book covers a new niche in circular accelerator design, motivated by the promising industrial prospects of recent micromanufacturing methods - X-ray lithography, synchrotron radiation-based micromachining and microanalysis techniques. It describes the basic concepts and the essential challenges for the development of compact synchrotron radiation sources from an accelerator designer's point of view and gives an outline of the actual state of the art. The volume is intended as an introduction and as a reference for physicists, engineers and managers involved in this rapidly developing fiel

  18. Synchrotron light source data book

    International Nuclear Information System (INIS)

    Murphy, J.

    1989-01-01

    The ''Synchrotron Light Source Data Book'' is as its name implies a collection of data on existing and planned synchrotron light sources. The intention was to provide a compendium of tools for the design of electron storage rings as synchrotron radiation sources. The slant is toward the accelerator physicist as other booklets such as the X-ray Data Booklet, edited by D. Vaughan (LBL PUB-490), address the 'use' of synchrotron radiation. It is hoped that the booklet serves as a pocket sized reference to facilitate back of the envelope type calculations. It contains some useful formulae in 'practical units' and a brief description of many of the existing and planned light source lattices

  19. The Compact Light Source A Miniature Synchrotron Light Source

    CERN Document Server

    Ruth, Ronald D

    2005-01-01

    During the past 30 years, synchrotron light sources have become the x-ray probe of choice for physicists, chemists, biologists and research physicians. With their high-quality, intense x-ray beams, these national research facilities have spawned a broad array of applications. Past research at Stanford Linear Accelerator Center has led to a new x-ray source concept that can substantially reduce the size of the required synchrotron.* This research has spawned a new corporation, Lyncean Technologies, Inc. which is now developing the Compact Light Source (CLS). The CLS is a tunable, homelab x-ray source with up to three beamlines that can be used like the x-ray beamlines at the synchrotrons-but it is about 200 times smaller than a synchrotron light source. The compact size is achieved using a laser undulator and a miniature electron-beam storage ring. The photon flux on a sample will be comparable to the flux of highly productive synchrotron beamlines. At Lyncean Technologies, Inc. we have constructed a prototype...

  20. Robust photometric stereo using structural light sources

    Science.gov (United States)

    Han, Tian-Qi; Cheng, Yue; Shen, Hui-Liang; Du, Xin

    2014-05-01

    We propose a robust photometric stereo method by using structural arrangement of light sources. In the arrangement, light sources are positioned on a planar grid and form a set of collinear combinations. The shadow pixels are detected by adaptive thresholding. The specular highlight and diffuse pixels are distinguished according to their intensity deviations of the collinear combinations, thanks to the special arrangement of light sources. The highlight detection problem is cast as a pattern classification problem and is solved using support vector machine classifiers. Considering the possible misclassification of highlight pixels, the ℓ1 regularization is further employed in normal map estimation. Experimental results on both synthetic and real-world scenes verify that the proposed method can robustly recover the surface normal maps in the case of heavy specular reflection and outperforms the state-of-the-art techniques.

  1. Surface-micromachined magnetic undulator with period length between 10μm and 1 mm for advanced light sources

    Science.gov (United States)

    Harrison, Jere; Joshi, Abhijeet; Lake, Jonathan; Candler, Rob; Musumeci, Pietro

    2012-07-01

    A technological gap exists between the μm-scale wiggling periods achieved using electromagnetic waves of high intensity laser pulses and the mm scale of permanent-magnet and superconducting undulators. In the sub-mm range, surface-micromachined soft-magnetic micro-electro-mechanical system inductors with integrated solenoidal coils have already experimentally demonstrated 100 to 500 mT field amplitude across air gaps as large as 15μm. Simulations indicate that magnetic fields as large as 1.5 T across 50μm inductor gaps are feasible. A simple rearranging of the yoke and pole geometry allows for fabrication of 10+ cm long undulator structures with period lengths between 12.5μm and 1 mm. Such undulators find application both in high average power spontaneous emission sources and, if used in combination with ultrahigh-brightness electron beams, could lead to the realization of low energy compact free-electron lasers. Challenges include electron energy broadening due to wakefields and Joule heating in the electromagnet.

  2. Iranian Light Source Facility, A third generation light source laboratory

    Directory of Open Access Journals (Sweden)

    J Rahighi

    2015-09-01

    Full Text Available The Iranian Light Source Facility (ILSF project is the first large scale accelerator facility which is currently under planning in Iran. On the basis of the present design, circumference of the 3 GeV storage ring is 528 m. Beam current and natural beam emittance are 400 mA and 0.477 nm.rad, respectively. Some prototype accelerator components such as high power solid state radio frequency amplifiers, low level RF system, thermionic RF gun, H-type dipole and quadruple magnets, magnetic measurement laboratory and highly stable magnet power supplies have been constructed at ILSF R&D laboratory

  3. Plant Growth Absorption Spectrum Mimicking Light Sources

    OpenAIRE

    Jou, Jwo-Huei; Lin, Ching-Chiao; Li, Tsung-Han; Li, Chieh-Ju; Peng, Shiang-Hau; Yang, Fu-Chin; Thomas, K.; Kumar, Dhirendra; Chi, Yun; Hsu, Ban-Dar

    2015-01-01

    Plant factories have attracted increasing attention because they can produce fresh fruits and vegetables free from pesticides in all weather. However, the emission spectra from current light sources significantly mismatch the spectra absorbed by plants. We demonstrate a concept of using multiple broad-band as well as narrow-band solid-state lighting technologies to design plant-growth light sources. Take an organic light-emitting diode (OLED), for example; the resulting light source shows an ...

  4. Driver circuit for solid state light sources

    Science.gov (United States)

    Palmer, Fred; Denvir, Kerry; Allen, Steven

    2016-02-16

    A driver circuit for a light source including one or more solid state light sources, a luminaire including the same, and a method of so driving the solid state light sources are provided. The driver circuit includes a rectifier circuit that receives an alternating current (AC) input voltage and provides a rectified AC voltage. The driver circuit also includes a switching converter circuit coupled to the light source. The switching converter circuit provides a direct current (DC) output to the light source in response to the rectified AC voltage. The driver circuit also includes a mixing circuit, coupled to the light source, to switch current through at least one solid state light source of the light source in response to each of a plurality of consecutive half-waves of the rectified AC voltage.

  5. Light Sources and Ballast Circuits

    Science.gov (United States)

    Yorifuji, Takashi; Sakai, Makoto; Yasuda, Takeo; Maehara, Akiyoshi; Okada, Atsunori; Gouriki, Takeshi; Mannami, Tomoaki

    discharge models were reported. Further, studies on ultra high-pressure mercury lamps as light sources for projectors are becoming the mainstream of HID lamp related researches. For high-pressure sodium lamps, many studies on plant growing and pest control utilizing low insect attracting aspects were also reported in 2006. Additionally, for discharge lamps, the minimum sustaining electric power for arc tubes employed in electrode-less compact fluorescent lamps was investigated. For Hg-free rare-gas fluorescent lamps, a luminance of 10,000cd/m2 was attained by a 1 meter-long external duplex spiral electrode prototype using Xe/Ne barrier discharge. As to startup circuits, the commercialization of energy saving and high value added products mainly associated with fluorescent lamps and HID lamps are becoming common. Further, the miniaturization of startup circuits for self electronic-ballasted lamps has advanced. Speaking of the overall light sources and startup circuits in 2006 and with the enforcement of RoHS in Europe in July, the momentum toward hazardous substance-free and energy saving initiatives has been enhanced from the perspective of protecting the global environment. It is anticipated that similar restrictions will be globally enforced in the future.

  6. Australian synchrotron light source - (boomerang)

    International Nuclear Information System (INIS)

    Boldeman, J.

    2001-01-01

    The Australian National Synchrotron Light Source - (Boomerang) is to be installed at the Monash University in Victoria. This report provides some background to the proposed facility and discusses aspects of a prospective design. Recently, significant effort was devoted to refining the in principle design and a lattice providing an emittance od 18 nm rad was obtained with a distributed dispersion in the straight section of 0.29m. Exhaustive studies have been made of the economic benefits that would accrue to Australia to Australia following the installation of this facility. This design is a refinement of the design concept presented to the SRI -2000, Berlin (Boldeman, Einfeld et al), to the meeting of the 4th Asian Forum and the Preliminary Design Study presented to the Australian Synchrotron Research Program

  7. Advanced Light Source control system

    International Nuclear Information System (INIS)

    Magyary, S.; Chin, M.; Cork, C.; Fahmie, M.; Lancaster, H.; Molinari, P.; Ritchie, A.; Robb, A.; Timossi, C.

    1989-03-01

    The Advanced Light Source (ALS) is a third generation 1--2 GeV synchrotron radiation source designed to provide ports for 60 beamlines. It uses a 50 MeV electron linac and 1.5 GeV, 1 Hz, booster synchrotron for injection into a 1--2 GeV storage ring. Interesting control problems are created because of the need for dynamic closed beam orbit control to eliminate interaction between the ring tuning requirements and to minimize orbit shifts due to ground vibrations. The extremely signal sensitive nature of the experiments requires special attention to the sources of electrical noise. These requirements have led to a control system design which emphasizes connectivity at the accelerator equipment end and a large I/O bandwidth for closed loop system response. Not overlooked are user friendliness, operator response time, modeling, and expert system provisions. Portable consoles are used for local operation of machine equipment. Our solution is a massively parallel system with >120 Mbits/sec I/O bandwidth and >1500 Mips computing power. At the equipment level connections are made using over 600 powerful Intelligent Local Controllers (ILC-s) mounted in 3U size Eurocard slots using fiber-optic cables between rack locations. In the control room, personal computers control and display all machine variables at a 10 Hz rate including the scope signals which are collected though the control system. Commercially available software and industry standards are used extensively. Particular attention is paid to reliability, maintainability and upgradeability. 10 refs., 11 figs

  8. Development of a circadian light source

    Science.gov (United States)

    Nicol, David B.; Ferguson, Ian T.

    2002-11-01

    Solid state lighting presents a new paradigm for lighting - controllability. Certain characteristics of the lighting environment can be manipulated, because of the possibility of using multiple LEDs of different emission wavelengths as the illumination source. This will provide a new, versatile, general illumination source due to the ability to vary the spectral power distribution. New effects beyond the visual may be achieved that are not possible with conventional light sources. Illumination has long been the primary function of lighting but as the lighting industry has matured the psychological aspects of lighting have been considered by designers; for example, choosing a particular lighting distribution or color variation in retail applications. The next step in the evolution of light is to consider the physiological effects of lighting that cause biological changes in a person within the environment. This work presents the development of a source that may have important bearing on this area of lighting. A circadian light source has been developed to provide an illumination source that works by modulating its correlated color temperature to mimic the changes in natural daylight through the day. In addition, this source can cause or control physiological effects for a person illuminated by it. The importance of this is seen in the human circadian rhythm's peak response corresponding to blue light at ~460 nm which corresponds to the primary spectral difference in increasing color temperature. The device works by adding blue light to a broadband source or mixing polychromatic light to mimic the variation of color temperature observed for the Planckian Locus on the CIE diagram. This device can have several applications including: a tool for researchers in this area, a general illumination lighting technology, and a light therapy device.

  9. Increasing the brightness of light sources

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Ling

    2006-11-16

    In this work the principle of light recycling is applied to artificial light sources in order to achieve brightness enhancement. Firstly, the feasibilities of increasing the brightness of light sources via light recycling are examined theoretically, based on the fundamental laws of thermodynamics including Kirchhoff's law on radiation, Planck's law, Lambert-Beer's law, the etendue conservation and the brightness theorem. From an experimental viewpoint, the radiation properties of three different kinds of light sources including short-arc lamps, incandescent lamps and LEDs characterized by their light-generating mechanisms are investigated. These three types of sources are used in light recycling experiments, for the purpose of 1. validating the intrinsic light recycling effect in light sources, e. g. the intrinsic light recycling effect in incandescent lamps stemming from the coiled filament structure. 2. acquiring the required parameters for establishing physical models, e.g. the emissivity/absorptivity of the short-arc lamps, the intrinsic reflectivity and the external quantum efficiency of LEDs. 3. laying the foundations for designing optics aimed at brightness enhancement according to the characteristics of the sources and applications. Based on the fundamental laws and experiments, two physical models for simulating the radiance distribution of light sources are established, one for thermal filament lamps, the other for luminescent sources, LEDs. As validation of the theoretical and experimental investigation of the light recycling effect, an optical device, the Carambola, is designed for achieving deterministic and multiple light recycling. The Carambola has the function of a concentrator. In order to achieve the maximum possible brightness enhancement with the Carambola, several combinations of sources and Carambolas are modelled in ray-tracing simulations. Sources with different light-emitting mechanisms and different radiation properties

  10. Light Sources Technologies and Applications

    CERN Document Server

    Kitsinelis, Spyridon

    2010-01-01

    From the dialogues of the ancient Greek philosophers right up through the physical laws of Newton, the experiments of Thomas Young and the quantum physics pioneers, the study of light was all about observing its characteristics and defining its behavior. At the end of the 19th century, wicks, wax, and oil gave way to electricity, filaments, and gases, and scientific minds began to focus on the technological creation of light, as well as its control and diverse uses. Yet, despite more than a century of profound research and development, until now, the most complete resources on lighting technol

  11. The JLab high power ERL light source

    Energy Technology Data Exchange (ETDEWEB)

    G.R. Neil; C. Behre; S.V. Benson; M. Bevins; G. Biallas; J. Boyce; J. Coleman; L.A. Dillon-Townes; D. Douglas; H.F. Dylla; R. Evans; A. Grippo; D. Gruber; J. Gubeli; D. Hardy; C. Hernandez-Garcia; K. Jordan; M.J. Kelley; L. Merminga; J. Mammosser; W. Moore; N. Nishimori; E. Pozdeyev; J. Preble; R. Rimmer; Michelle D. Shinn; T. Siggins; C. Tennant; R. Walker; G.P. Williams and S. Zhang

    2005-03-19

    A new THz/IR/UV photon source at Jefferson Lab is the first of a new generation of light sources based on an Energy-Recovered, (superconducting) Linac (ERL). The machine has a 160 MeV electron beam and an average current of 10 mA in 75 MHz repetition rate hundred femtosecond bunches. These electron bunches pass through a magnetic chicane and therefore emit synchrotron radiation. For wavelengths longer than the electron bunch the electrons radiate coherently a broadband THz {approx} half cycle pulse whose average brightness is > 5 orders of magnitude higher than synchrotron IR sources. Previous measurements showed 20 W of average power extracted[1]. The new facility offers simultaneous synchrotron light from the visible through the FIR along with broadband THz production of 100 fs pulses with >200 W of average power. The FELs also provide record-breaking laser power [2]: up to 10 kW of average power in the IR from 1 to 14 microns in 400 fs pulses at up to 74.85 MHz repetition rates and soon will produce similar pulses of 300-1000 nm light at up to 3 kW of average power from the UV FEL. These ultrashort pulses are ideal for maximizing the interaction with material surfaces. The optical beams are Gaussian with nearly perfect beam quality. See www.jlab.org/FEL for details of the operating characteristics; a wide variety of pulse train configurations are feasible from 10 microseconds long at high repetition rates to continuous operation. The THz and IR system has been commissioned. The UV system is to follow in 2005. The light is transported to user laboratories for basic and applied research. Additional lasers synchronized to the FEL are also available. Past activities have included production of carbon nanotubes, studies of vibrational relaxation of interstitial hydrogen in silicon, pulsed laser deposition and ablation, nitriding of metals, and energy flow in proteins. This paper will present the status of the system and discuss some of the discoveries we have made

  12. A compact, coherent light source system architecture

    NARCIS (Netherlands)

    Biedron, S.G.; Dattoli, G.; Dipalma, E.; Einstein, J.; Milton, S.V.; Petrillo, V.; Rau, J. V.; Sabia, E.; Spassovsky, I.P.; Van Der Slot, P. J.M.

    2016-01-01

    Our team has been examining several architectures for short-wavelength, coherent light sources. We are presently exploring the use and role of advanced, high-peak power lasers for both accelerating the electrons and generating a compact light source with the same laser. Our overall goal is to devise

  13. Blue enhanced light sources: opportunities and risks

    Science.gov (United States)

    Lang, Dieter

    2012-03-01

    Natural daylight is characterized by high proportions of blue light. By proof of a third type of photoreceptor in the human eye which is only sensitive in this spectral region and by subsequent studies it has become obvious that these blue proportions are essential for human health and well being. In various studies beneficial effects of indoor lighting with higher blue spectral proportions have been proven. On the other hand with increasing use of light sources having enhanced blue light for indoor illumination questions are arising about potential health risks attributed to blue light. Especially LED are showing distinct emission characteristics in the blue. Recently the French agency for food, environmental and occupational health & safety ANSES have raised the question on health issues related to LED light sources and have claimed to avoid use of LED for lighting in schools. In this paper parameters which are relevant for potential health risks will be shown and their contribution to risk factors will quantitatively be discussed. It will be shown how to differentiate between photometric parameters for assessment of beneficial as well as hazardous effects. Guidelines will be discussed how blue enhanced light sources can be used in applications to optimally support human health and well being and simultaneously avoid any risks attributed to blue light by a proper design of lighting parameters. In the conclusion it will be shown that no inherent health risks are related to LED lighting with a proper lighting design.

  14. High-Energy Compton Scattering Light Sources

    CERN Document Server

    Hartemann, Fred V; Barty, C; Crane, John; Gibson, David J; Hartouni, E P; Tremaine, Aaron M

    2005-01-01

    No monochromatic, high-brightness, tunable light sources currently exist above 100 keV. Important applications that would benefit from such new hard x-ray sources include: nuclear resonance fluorescence spectroscopy, time-resolved positron annihilation spectroscopy, and MeV flash radiography. The peak brightness of Compton scattering light sources is derived for head-on collisions and found to scale with the electron beam brightness and the drive laser pulse energy. This gamma 2

  15. Ring insertions as light sources

    International Nuclear Information System (INIS)

    Green, G.K.

    1975-01-01

    Bending magnets can be inserted in the long straight sections of electron storage rings to produce synchrotron radiation. If the design is carefully proportioned, the bending magnets create only a small perturbation of the properties of the ring. The resulting spectra have favorable optical properties as sources for spectroscopy and diffraction studies. The characteristics of the source are discussed, and the geometrical requirements of the magnets are presented

  16. COMPARATIVE STUDY OF LIGHT SOURCES FOR HOUSEHOLD

    Directory of Open Access Journals (Sweden)

    Andrzej PAWLAK

    2017-01-01

    Full Text Available The article describes test results that provided the ground to define and evaluate basic photometric, colorimetric and electric parameters of selected, widely available light sources, which are equivalent to a traditional incandescent 60-Watt light bulb. Overall, one halogen light bulb, three compact fluorescent lamps and eleven LED light sources were tested. In general, it was concluded that in most cases (branded products, in particular the measured and calculated parameters differ from the values declared by manufacturers only to a small degree. LED sources prove to be the most beneficial substitute for traditional light bulbs, considering both their operational parameters and their price, which is comparable with the price of compact fluorescent lamps or, in some instances, even lower.

  17. National Synchrotron Light Source annual report 1988

    Energy Technology Data Exchange (ETDEWEB)

    Hulbert, S.; Lazarz, N.; Williams, G. (eds.)

    1988-01-01

    This report discusses the experiment done at the National Synchrotron Light Source. Most experiments discussed involves the use of the x-ray beams to study physical properties of solid materials. (LSP)

  18. Advanced Light Source Activity Report 2002

    International Nuclear Information System (INIS)

    Duque, Theresa; Greiner, Annette; Moxon, Elizabeth; Robinson, Arthur; Tamura, Lori

    2003-01-01

    This annual report of the Advanced Light Source details science highlights and facility improvements during the year. It also offers information on events sponsored by the facility, technical specifications, and staff and publication information

  19. Advanced Light Source Activity Report 2000

    Energy Technology Data Exchange (ETDEWEB)

    Greiner, A.; Moxon, L.; Robinson, A.; Tamura, L.

    2001-04-01

    This is an annual report, detailing activities at the Advanced Light Source for the year 2000. It includes highlights of scientific research by users of the facility as well as information about the development of the facility itself.

  20. Advanced Light Source Activity Report 2000

    International Nuclear Information System (INIS)

    Greiner, A.; Moxon, L.; Robinson, A.; Tamura, L.

    2001-01-01

    This is an annual report, detailing activities at the Advanced Light Source for the year 2000. It includes highlights of scientific research by users of the facility as well as information about the development of the facility itself

  1. Advanced Light Source Activity Report 2002

    Energy Technology Data Exchange (ETDEWEB)

    Duque, Theresa; Greiner, Annette; Moxon, Elizabeth; Robinson, Arthur; Tamura, Lori (Editors)

    2003-06-12

    This annual report of the Advanced Light Source details science highlights and facility improvements during the year. It also offers information on events sponsored by the facility, technical specifications, and staff and publication information.

  2. Photobiocatalytic alcohol oxidation using LED light sources

    NARCIS (Netherlands)

    Rauch, M.C.R.; Schmidt, S.; Arends, I.W.C.E.; oppelt, K.; Kara, S; Hollmann, F.

    2016-01-01

    The photocatalytic oxidation of NADH using a flavin photocatalyst and a simple blue LED light source is reported. This in situ NAD+ regeneration system can be used to promote biocatalytic, enantioselective oxidation reactions. Compared to the traditional use of white light bulbs this method enables

  3. Uniform variable light sources for instrument calibration.

    Science.gov (United States)

    Squyres, H P; Rennilson, J J

    1970-05-01

    This paper describes light sources that were developed for use in calibrating cameras for space exploration. The design produces a nearly uniform luminance field whose correlated color temperature ranges from 4000 K to 5000 K in the visible. Luminance of the source may be continuously varied by as much as 500:1 without affecting the uniformity of the field. The sources, consisting basically of two integrating cavities with an iris diaphragm interposed, use xenon light. Luminances as high as 25,000 cd m(-2) are possible. Such sources are used for light-transfer calibration, as well as spectral response of camera systems. After a brief theoretical treatment, the design variations are discussed. Measurement data on these sources indicates that the angular luminance distribution approximates a uniform diffuser within a 50-deg cone.

  4. Ideas for future synchrotron light sources

    International Nuclear Information System (INIS)

    Jackson, A.; Hassenzahl, W.; Meddahi, M.

    1992-03-01

    Synchrotron light sources have advanced in the past two-to-three decades through three ''generations,'' from irritating parasitic sources on high-energy physics accelerators to dedicated electron and position storage rings of unprecedented low emittance, utilizing undulator and wiggler magnets. The evolution through these three generations followed a predicable, science-driven, course towards brighter beams of VUV- and x-radiation. The requirements of future light sources is not so clear. The limit on how emittance has certainly not been reached, and diffraction-limited sources at shorter wavelengths would be the natural progression from previous generations. However, scientists are now looking at other radiation characteristics that might better serve their needs, for example, more coherent power, fast switching polarization, ultra-short (sub-picosecond) time structure, and synchronized beams for pump-probe experiments. This paper discusses some current ideas that might drive the fourth-generation synchrotron light source

  5. Supercontinuum light sources for food analysis

    DEFF Research Database (Denmark)

    Møller, Uffe Visbech; Petersen, Christian Rosenberg; Kubat, Irnis

    2014-01-01

    and in the factory. These solutions will combine bright and broadband infrared light sources, so-called supercontinuum light sources,with spectroscopy, chemometrics and processing expertise and thereby contribute to increased food quality through faster and more precise analysis of grains, soils and dairy products...... bandwidth,high brightness and portability of a supercontinuum laser are all required. DTU Fotonik has now demonstrated the first optical fiber based broadband supercontinuum light souce, which covers 1.4-13.3μm and thereby most of the molecular fingerprint region....

  6. Boomerang - the Australian light source

    International Nuclear Information System (INIS)

    Boldeman, J.W.; Garrett, R.F.

    2000-01-01

    Full text: The Australian Synchrotron Research Program (ASRP) was one of seven major national research facilities funded by the Federal Government in December 1995. The program provides guaranteed access and travel funds for Australian scientists to conduct synchrotron radiation-based research at two overseas facilities - the Photon Factory at Tsukuba in Japan and the Advanced Photon Source at the Argonne National Laboratory in the US. The Federal Government also provided funding of $100K to carry out a Feasibility Study for an Australian-based facility. This has been completed and included a mission to a number of laboratories overseas that were or had recently constructed a facility that could be considered for Australia. Following the mission, consensus was achieved within the community for the specifications of a proposed Australian facility. The proposed facility, Boomerang, has an energy of 3 GeV, an emittance of 16 nm rad and will be equipped in the first phase with 9 instrument stations. Boomerang will be competitive in performance with other facilities currently under construction overseas. A detailed proposal has been submitted to the Federal Government for funding. No site has been specified in the proposal. The proposal was prepared within the Australian Synchrotron Research Program (ASRP) following extensive consultation with industrial and scientific groups in all Australian states. Valuable contributions have been made by members of all the committees of the ASRP, the Australian synchrotron research community that works through the ASRP and the National Synchrotron Steering Committee. Important contributions have also been made by many industrial groups including consortia in Victoria, Queensland and New South Wales. The input from the ANKA staff at Forschungszentrum Karlsruhe and, in particular. Professor Einfeld has been a critical component. The estimated capital cost of a no frills laboratory has been estimated to be $100M in 1999 dollars. The

  7. GPC light shaping a supercontinuum source

    DEFF Research Database (Denmark)

    Kopylov, Oleksii; Bañas, Andrew Rafael; Villangca, Mark Jayson

    2015-01-01

    Generalized Phase Contrast (GPC) is a versatile tool for efficiently rerouting and managing photon energy into speckle-free contiguous spatial light distributions. We have previously shown theoretically and numerically that a GPC Light Shaper shows robustness to shift in wavelength and can maintain...... both projection length scale and high efficiency over a range [0.75λ0; 1.5λ0] with λ0 as the characteristic design wavelength. With this performance across multiple wavelengths and the recent availability of tabletop supercontinuum lasers, GPC light shaping opens the possibility for creatively...... incorporating various multi-wavelength approaches into spatially shaped excitations that can enable new broadband light applications. We verify this new approach using a supercontinuum light source, interfaced with a compact GPC light shaper. Our experiments give ~70% efficiency, ~3x intensity gain, and ~85...

  8. Plant Growth Absorption Spectrum Mimicking Light Sources

    Directory of Open Access Journals (Sweden)

    Jwo-Huei Jou

    2015-08-01

    Full Text Available Plant factories have attracted increasing attention because they can produce fresh fruits and vegetables free from pesticides in all weather. However, the emission spectra from current light sources significantly mismatch the spectra absorbed by plants. We demonstrate a concept of using multiple broad-band as well as narrow-band solid-state lighting technologies to design plant-growth light sources. Take an organic light-emitting diode (OLED, for example; the resulting light source shows an 84% resemblance with the photosynthetic action spectrum as a twin-peak blue dye and a diffused mono-peak red dye are employed. This OLED can also show a greater than 90% resemblance as an additional deeper red emitter is added. For a typical LED, the resemblance can be improved to 91% if two additional blue and red LEDs are incorporated. The approach may facilitate either an ideal use of the energy applied for plant growth and/or the design of better light sources for growing different plants.

  9. Research on Modern Gas Discharge Light Sources

    Science.gov (United States)

    Born, M.; Markus, T.

    This article gives an overview of today's gas discharge light sources and their application fields with focus on research aspects. In Sect. 15.1 of this chapter, an introduction to electric light sources, the lighting market and related research topics is outlined. Due to the complexity of the subject, we have focused on selected topics in the field of high intensity discharge (HID) lamps since these represent an essential part of modern lamp research. The working principle and light technical properties of HID lamps are described in Sect. 15.2. Physical and thermochemical modelling procedures and tools as well as experimental analysis are discussed in Sects. 15.3 and 15.4, respectively. These tools result in a detailed scientific insight into the complexity of real discharge lamps. In particular, analysis and modelling are the keys for further improvement and development of existing and new products.

  10. IR microscopy utilizing intense supercontinuum light source

    DEFF Research Database (Denmark)

    Dupont, Sune; Petersen, Christian; Thøgersen, Jan

    2012-01-01

    Combining the molecular specificity of the infrared spectral region with high resolution microscopy has been pursued by researchers for decades. Here we demonstrate infrared supercontinuum radiated from an optical fiber as a promising new light source for infrared microspectroscopy. The supercont......Combining the molecular specificity of the infrared spectral region with high resolution microscopy has been pursued by researchers for decades. Here we demonstrate infrared supercontinuum radiated from an optical fiber as a promising new light source for infrared microspectroscopy....... The supercontinuum light source has a high brightness and spans the infrared region from 1400 nm to 4000 nm. This combination allows contact free high resolution hyper spectral infrared microscopy. The microscope is demonstrated by imaging an oil/water sample with 20 μm resolution....

  11. High gradient accelerators for linear light sources

    Energy Technology Data Exchange (ETDEWEB)

    Barletta, W.A.

    1988-09-26

    Ultra-high gradient radio frequency linacs powered by relativistic klystrons appear to be able to provide compact sources of radiation at XUV and soft x-ray wavelengths with a duration of 1 picosecond or less. This paper provides a tutorial review of the physics applicable to scaling the present experience of the accelerator community to the regime applicable to compact linear light sources. 22 refs., 11 figs., 21 tabs.

  12. Tunable light source for fiber optic lighting applications

    Science.gov (United States)

    Narendran, Nadarajah; Bierman, Andrew; Finney, Mark J.; Edwards, Ian K.

    1997-09-01

    This paper examines the possibility of tuning the lamp spectrum to compensate for color distortions in fiber optic lighting systems. Because most optical fibers have strong absorption in the blue and red wavelength regions, white light entering and propagating down an optical fiber suffers varied amounts of attenuation as a function of wavelength. As a result, the light exiting the optical fiber has a greenish tint that the lighting design community considers undesirable in interior lighting applications. HID lamps are commonly used for the light source in this industry. Certain classes of HID lamps tend to shift in color when their operating position or the input voltage to the lamp is changed. An experimental study is being conducted to characterize the color shift properties of a small HID lamp as a function of tilt and input voltage. The study also examines the possibility of exploiting this color shift to compensate for the color distortions caused by optical fibers. The details of the experiment and the results are presented in this manuscript.

  13. The national synchrotron light source and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Williams, G.P.

    1989-01-01

    We describe the National Synchrotron Light Source facility including its beamlines and operational characteristics. Research results on selected beamlines on the VUV ring which highlight new experimental capabilities are described since they are more relevant to the program at HESYRL. Examples chosen are spin-polarized photoemission, infra-red surface science, high resolution core level spectroscopy, X- Ray lithography, photoelectron/Auger coincidence spectroscopy and high electron momentum resolution surface studies. 7 refs., 3 figs., 3 tabs.

  14. Long-pulse Supercontinuum Light Sources

    DEFF Research Database (Denmark)

    Moselund, Peter M.

    A Supercontinuum (SC) is a broad spectrum generated from a narrow light source through non-linear effects. This thesis describes SC generation based on 1064 nm ps pulses in PCF fibres. We investigate how the SC spectrum can be modified and intensity noise reduced by feeding back part of the SC...

  15. Light induced modulation instability of surfaces under intense illumination

    KAUST Repository

    Burlakov, V. M.

    2013-12-17

    We show that a flat surface of a polymer in rubber state illuminated with intense electromagnetic radiation is unstable with respect to periodic modulation. Initial periodic perturbation is amplified due to periodic thermal expansion of the material heated by radiation. Periodic heating is due to focusing-defocusing effects caused by the initial surface modulation. The surface modulation has a period longer than the excitation wavelength and does not require coherent light source. Therefore, it is not related to the well-known laser induced periodic structures on polymer surfaces but may contribute to their formation and to other phenomena of light-matter interaction.

  16. An Upgrade for the Advanced Light Source

    International Nuclear Information System (INIS)

    Chemla, Daniel S.; Feinberg, Benedict; Hussain, Zahid; Kirz, Janos; Krebs, Gary F.; Padmore, Howard A.; Robin, David S.; Robinson, Arthur L.; Smith, Neville V.

    2004-01-01

    One of the first third-generation synchrotron light sources, the ALS, has been operating for almost a decade at Berkeley Lab, where experimenters have been exploiting its high brightness for forefront science. However, accelerator and insertion-device technology have significantly changed since the ALS was designed. As a result, the performance of the ALS is in danger of being eclipsed by that of newer, more advanced sources. The ALS upgrade that we are planning includes full-energy, top-off injection with higher storage-ring current and the replacement of five first-generation insertion devices with nine state-of-the art insertion devices and four new application-specific beamlines now being identified in a strategic planning process. The upgrade will help keep the ALS at the forefront of soft x-ray synchrotron light sources for the next two decades

  17. [Quality control research of cold light source of endoscope].

    Science.gov (United States)

    Shao, Yubo; Yuan, Fuqiang; Liu, Yanzhen; Wang, Quan; Meng, Xiangfeng

    2014-09-01

    This paper introduced the significance parameters of the quality control of cold light source of endoscope, expounded the importance and necessity of quality control of cold light source; it investigated several manufacturers, analyzed and discussed the main causes of the cold light source uneven, in order to realized the standard management and effective supervision on the cold light source, at the end, the next step quality control work was brought out, which provide technical support for quality supervision of cold light source.

  18. Advanced Light Source: Activity report 1993

    International Nuclear Information System (INIS)

    1994-11-01

    The Advanced Light Source (ALS) produces the world's brightest light in the ultraviolet and soft x-ray regions of the spectrum. The first low-energy third-generation synchrotron source in the world, the ALS provides unprecedented opportunities for research in science and technology not possible anywhere else. This year marked the beginning of operations and the start of the user research program at the ALS, which has already produced numerous high quality results. A national user facility located at Lawrence Berkeley Laboratory of the University of California, the ALS is available to researchers from academia, industry, and government laboratories. This report contains the following: (1) director's message; (2) operations overview; (3) user program; (4) users' executive committee; (5) industrial outreach; (6) accelerator operations; (7) beamline control system; (8) insertion devices; (9) experimental systems; (10) beamline engineering; (11) first results from user beamlines; (12) beamlines for 1994--1995; (13) special events; (14) publications; (15) advisory panels; and (16) ALS staff

  19. Advanced Light Source beam diagnostics systems

    International Nuclear Information System (INIS)

    Hinkson, J.

    1993-10-01

    The Advanced Light Source (ALS), a third-generation synchrotron light source, has been recently commissioned. Beam diagnostics were very important to the success of the operation. Each diagnostic system is described in this paper along with detailed discussion of its performance. Some of the systems have been in operation for two years. Others, in the storage ring, have not yet been fully commissioned. These systems were, however, working well enough to provide the essential information needed to store beam. The devices described in this paper include wall current monitors, a beam charge monitor, a 50 ohm Faraday cup, DC current transformers, broad-hand striplines, fluorescence screens, beam collimators and scrapers, and beam position monitors. Also, the means by which waveforms are digitized and displayed in the control room is discussed

  20. Photon Science at Modern Light Sources

    Science.gov (United States)

    Arthur, John

    2009-12-01

    More than 50 large x-ray and UV light sources based on high-energy electron accelerators are in operation around the world, serving a scientific community numbering in the tens of thousands. These sources generate synchrotron radiation from accelerated electrons or positrons. The development of synchrotron light sources over the last 40 years has fueled an exponential increase in x-ray source brightness of more than 10 orders of magnitude. The next large advance in source potential is now underway, with the commissioning of the first x-ray Free-Electron Laser (FEL) sources. Using high-energy electron linear accelerators, these facilities produce sub-picosecond pulses of hard x-rays with peak brightness more than 10 orders of magnitude greater than current synchrotron facilities. FEL x-ray facilities will soon be operational in the US, Japan, and Germany. Research at modern light sources makes use of a wide range of experimental techniques. Many experiments are designed to study the structure of matter at the atomic scale using elastic x-ray scattering. This technique has been particularly effective for determining the structures of biological molecules, such as proteins, viruses, and drugs. Inelastic x-ray scattering, or x-ray absorption followed by emission of electrons or photons, can give information about the electronic structures of atoms, which can be used to deduce local environment information such as atomic species, bonding state, geometry of neighboring atoms, or magnetic state. For some techniques involving x-ray emission from a sample, cryogenic detectors with energy resolution at the ˜10 eV level or better would be very helpful. Shifts in electron energy levels associated with bonding states and magnetic states are typically several eV, while the energy structure associated with Compton inelastic scattering is typically in the range of a few tens of eV. Current energy-resolving detectors used at synchrotron light sources are hampered by either poor

  1. Towards an integrated squeezed light source

    DEFF Research Database (Denmark)

    Gehring, Tobias; Hoff, Ulrich Busk; Iskhakov, Timur

    2017-01-01

    Since it's first generation more than 30 years ago, squeezed light has developed towards a tool for high precision measurements as well as a tool for quantum information tasks like quantum key distribution. Miniaturization of sensors is an active field of research with the prospect of many......-track resonators in silicon nitride by presenting characterizations of the chip. Using standard fabrication techniques this source will have the potential of seamless integration into on-chip optical sensors....

  2. Pioneering SESAME light source officially opened

    CERN Multimedia

    Caraban Gonzalez, Noemi

    2017-01-01

    Allan, Jordan, 16 May 2017. The SESAME light source was today officially opened by His Majesty King Abdullah II. An intergovernmental organization, SESAME is the first regional laboratory for the Middle East and neighbouring regions The laboratory’s official opening ushers in a new era of research covering fields ranging from medicine and biology, through materials science, physics and chemistry to healthcare, the environment, agriculture and archaeology.

  3. Surface-micromachined magnetic undulator with period length between 10  μm and 1 mm for advanced light sources

    Directory of Open Access Journals (Sweden)

    Jere Harrison

    2012-07-01

    Full Text Available A technological gap exists between the μm-scale wiggling periods achieved using electromagnetic waves of high intensity laser pulses and the mm scale of permanent-magnet and superconducting undulators. In the sub-mm range, surface-micromachined soft-magnetic micro-electro-mechanical system inductors with integrated solenoidal coils have already experimentally demonstrated 100 to 500 mT field amplitude across air gaps as large as 15  μm. Simulations indicate that magnetic fields as large as 1.5 T across 50  μm inductor gaps are feasible. A simple rearranging of the yoke and pole geometry allows for fabrication of 10+ cm long undulator structures with period lengths between 12.5  μm and 1 mm. Such undulators find application both in high average power spontaneous emission sources and, if used in combination with ultrahigh-brightness electron beams, could lead to the realization of low energy compact free-electron lasers. Challenges include electron energy broadening due to wakefields and Joule heating in the electromagnet.

  4. Toward a fourth-generation light source

    International Nuclear Information System (INIS)

    Moncton, D. E.

    1999-01-01

    Historically, x-ray research has been propelled by the existence of urgent and compelling scientific questions and the push of powerful and exquisite source technology. These two factors have gone hand in hand since Rontgen discovered x-rays. Here we review the progress being made with existing third-generation synchrotron-radiation light sources and the prospects for a fourth-generation light source with dramatically improved laser-like beam characteristics. The central technology for high-brilliance x-ray beams is the x-ray undulator, a series of alternating-pole magnets situated above and below the particle beam. When the particle beam is oscillated by the alternating magnetic fields, a set of. interacting and interfering wave fronts is produced, which leads to an x-ray beam with extraordinary properties. Third-generation sources of light in the hard x-ray range have been constructed at three principal facilities: the European Synchrotrons Radiation Facility (ESRF) in France; the Super Photon Ring 8-GeV (or Spring-8) in Japan; and the Advanced Photon Source (APS) in the US. Undulator technology is also used on a number of low-energy machines for radiation in the ultraviolet and soft x-ray regimes. At the APS, these devices exceed all of our original expectations for beam brilliance, tunability, spectral range, and operational flexibility. Shown in Fig. 1 are the tuning curves of the first few harmonics, showing x-ray production from a few kV to better than 40 keV. High-brilliance radiation extends to over 100 keV

  5. Challenges of Linac Driven Light Sources

    CERN Document Server

    Bocchetta, C J

    2004-01-01

    The use of linacs allows novel light sources to be conceived by not being limited by equilibrium dynamics or IBS effects. These new sources can be single pass or recirculated (with or without energy recovery) or linac augmented storage rings. They allow tuneable polarised radiation of unprecedented brilliance, short pulse lengths that may reach the atto-second scale and full coherence. Both SC and NC machines are being proposed, designed and constructed. Photon output characteristics range from incoherent synchrotron radiation to SASE to seeded HGHG. The proposed beams can be low to high average current and pulse time structures range from CW to highly variable with mutual exclusion amongst different forms of operation. The multiple challenges of these machines reside not only in the requirement of beams of extremely high quality (energy, emittance, energy-spread and temporal stability) for the brightest, shortest wavelength sources but also in the demanding technologies and control of beam-machine interactio...

  6. Retinal endoilluminator toxicity of xenon and light-emitting diode (LED) light source: rabbit model.

    Science.gov (United States)

    Aydin, Bahri; Dinç, Erdem; Yilmaz, S Necat; Altiparmak, U Emrah; Yülek, Fatma; Ertekin, Sevda; Yilmaz, Mustafa; Yakın, Mehmet

    2014-09-01

    This study evaluates retinal toxicity due to endoillumination with the light-emitting diode (LED) light source in comparison to endoillumination with xenon light source. Twenty-five eyes of 14 New Zealand pigmented rabbits were used in the study. The LED light (Omesis Medical Systems, Turkey) group was composed of 7 right eyes, while the other 7 right eyes constituted the xenon group (420 nm filter, 357mW/cm(2)) (Bright Star; DORC, Zuidland, Netherlands). Eleven untreated left eyes composed the control group. Twenty gauge pars plana incision 1.5 mm behind the limbus was performed in the right eyes. Twenty gauge bullet type fiberoptic endoilluminator was inserted into the eye from the incision without any pars plana vitrectomy. Fiberoptic endoilluminator was placed in such a way that it was directed toward visual streak of the rabbit retina with a 5 mm distance to retinal surface. Endoillumination was then applied for 20 min with a maximum light intensity for LED and xenon light. In left control eyes, no surgical procedure and no endoillumination were performed. One week after the endoillumination procedure, both eyes of the rabbits were enucleated following electroretinography. Sections stained with hematoxylin and eosin to evaluate morphologic changes. Retina tissues were assessed by active caspase-3 staining. There was no difference in the shape of the waveforms recorded in the eyes endoilluminated with LED light and xenon light sources compared to control eyes both before and after endoillumination application (p > 0.05). Microscopic evaluation of the retinas with hematoxylin and eosin staining demonstrated that all study groups have normal histologic properties similar to control group. No apoptosis positive cells were found within all sections in all groups. When the LED light source is used with maximum power and limited duration for endoillumination in rabbit eyes it does not produce phototoxic effects that may be detectable by electrophysiology

  7. New Light Source Setup for Angle Resolved Light Absorption measurement of PV samples

    DEFF Research Database (Denmark)

    Amdemeskel, Mekbib Wubishet; Poulsen, Peter Behrensdorff; Thorsteinsson, Sune

    Here, we introduce measurements of angle resolved light absorption by PV cells, using broadband laser driven white light source with a bright, stable, broad spectral range and well collimated light.......Here, we introduce measurements of angle resolved light absorption by PV cells, using broadband laser driven white light source with a bright, stable, broad spectral range and well collimated light....

  8. New Light Source Setup for Angle Resolved Light Absorption measurement of PV sample

    DEFF Research Database (Denmark)

    Amdemeskel, Mekbib Wubishet; Poulsen, Peter Behrensdorff; Thorsteinsson, Sune

    Here, we introduce measurements of angle resolved light absorption by PV cells, using broadband laser driven white light source with a bright, stable, broad spectral range and well collimated light.......Here, we introduce measurements of angle resolved light absorption by PV cells, using broadband laser driven white light source with a bright, stable, broad spectral range and well collimated light....

  9. Superbend upgrade of the Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Robin, D.; Krupnick, J.; Schlueter, R.; Steier, C.; Marks, S.; Wang, B.; Zbasnik, J.; Benjegerdes, R.; Biocca, A.; Bish, P.; Brown, W.; Byrne, W.; Chen, J.; Decking, W.; DeVries, J.; DeMarco, W.R.; Fahmie, M.; Geyer, A.; Harkins, J.; Henderson, T.; Hinkson, J.; Hoyer, E.; Hull, D.; Jacobson, S.; McDonald, J.; Molinari, P.; Mueller, R.; Nadolski, L.; Nishimura, H.; Nishimura, K.; Ottens, F.; Paterson, J.A.; Pipersky, P.; Portmann, G.; Richie, A.; Rossi, S.; Salvant, B.; Scarvie, T.; Schmidt,A.; Spring, J.; Taylor, C.; Thur, W.; Timossi, C.; Wandesforde, A.

    2004-05-26

    The Advanced Light Source (ALS) is a third generation synchrotron light source located at Lawrence Berkeley National Laboratory (LBNL). There was an increasing demand at the ALS for additional high brightness hard x-ray beamlines in the 7 to 40 keV range. In response to that demand, the ALS storage ring was modified in August 2001. Three 1.3 Tesla normal conducting bending magnets were removed and replaced with three 5 Tesla superconducting magnets (Superbends). The radiation produced by these Superbends is an order of magnitude higher in photon brightness and flux at 12 keV than that of the 1.3 Tesla bends, making them excellent sources of hard x-rays for protein crystallography and other hard x-ray applications. At the same time the Superbends did not compromise the performance of the facility in the VUV and soft x-ray regions of the spectrum. The Superbends will eventually feed 12 new beamlines greatly enhancing the facility's capability and capacity in the hard x-ray region. The Superbend project is the biggest upgrade to the ALS storage ring since it was commissioned in 1993. In this paper we present an overview of the Superbend project, its challenges and the resulting impact on the ALS.

  10. Directly Phase-Modulated Light Source

    Directory of Open Access Journals (Sweden)

    Z. L. Yuan

    2016-09-01

    Full Text Available The art of imparting information onto a light wave by optical signal modulation is fundamental to all forms of optical communication. Among many schemes, direct modulation of laser diodes stands out as a simple, robust, and cost-effective method. However, the simultaneous changes in intensity, frequency, and phase have prevented its application in the field of secure quantum communication. Here, we propose and experimentally demonstrate a directly phase-modulated light source which overcomes the main disadvantages associated with direct modulation and is suitable for diverse applications such as coherent communications and quantum cryptography. The source separates the tasks of phase preparation and pulse generation between a pair of semiconductor lasers leading to very pure phase states. Moreover, the cavity-enhanced electro-optic effect enables the first example of subvolt half-wave phase modulation at high signal rates. The source is compact, stable, and versatile, and we show its potential to become the standard transmitter for future quantum communication networks based on attenuated laser pulses.

  11. Plasma-based EUV light source

    Science.gov (United States)

    Shumlak, Uri; Golingo, Raymond; Nelson, Brian A.

    2010-11-02

    Various mechanisms are provided relating to plasma-based light source that may be used for lithography as well as other applications. For example, a device is disclosed for producing extreme ultraviolet (EUV) light based on a sheared plasma flow. The device can produce a plasma pinch that can last several orders of magnitude longer than what is typically sustained in a Z-pinch, thus enabling the device to provide more power output than what has been hitherto predicted in theory or attained in practice. Such power output may be used in a lithography system for manufacturing integrated circuits, enabling the use of EUV wavelengths on the order of about 13.5 nm. Lastly, the process of manufacturing such a plasma pinch is discussed, where the process includes providing a sheared flow of plasma in order to stabilize it for long periods of time.

  12. Advanced Light Source beam position monitor

    International Nuclear Information System (INIS)

    Hinkson, J.

    1991-01-01

    The Advanced Light Source (ALS) is a synchrotron radiation facility nearing completion at LBL. As a third-generation machine, the ALS is designed to produce intense light from bend magnets, wigglers, and undulators (insertion devices). The facility will include a 50 MeV electron linear accelerator, a 1.5 GeV booster synchrotron, beam transport lines, a 1--2 GeV storage ring, insertion devices, and photon beam lines. Currently, the beam injection systems are being commissioned, and the storage ring is being installed. Electron beam position monitors (BPM) are installed throughout the accelerator and constitute the major part of accelerator beam diagnostics. The design of the BPM instruments is complete, and 50 units have been constructed for use in the injector systems. We are currently fabricating 100 additional instruments for the storage ring. In this paper I discuss engineering fabrication, testing and performance of the beam pickup electrodes and the BPM electronics

  13. Towards Light Sources Featuring Superconducting Miniundulators

    Science.gov (United States)

    Moser, H. O.; Diao, C. Z.

    Besides the exploitation of the Helios 2 superconducting compact storage ring for user operations and for its own R&D work, SSLS envisions a 4th generation synchrotron light source to complement and, eventually, replace the current facility. This vision includes an accelerator system based on a superconducting linear accelerator with up to 5 recirculation loops for energy multiplication and recovery with the distinguishing feature that the light would be generated by superconducting mini- and micro-undulators. Under this programme, SSLS is pursuing the development of superconducting miniundulators including a proof-of-technology electron beam experiment in co-operation with the Shanghai Institute of Applied Physics and the analytical and numerical study of the fabrication tolerances of superconducting miniundulators with respect to their finite length field errors and mechanical errors.

  14. Attosecond light sources in the water window

    Science.gov (United States)

    Ren, Xiaoming; Li, Jie; Yin, Yanchun; Zhao, Kun; Chew, Andrew; Wang, Yang; Hu, Shuyuan; Cheng, Yan; Cunningham, Eric; Wu, Yi; Chini, Michael; Chang, Zenghu

    2018-02-01

    As a compact and burgeoning alternative to synchrotron radiation and free-electron lasers, high harmonic generation (HHG) has proven its superiority in static and time-resolved extreme ultraviolet spectroscopy for the past two decades and has recently gained many interests and successes in generating soft x-ray emissions covering the biologically important water window spectral region. Unlike synchrotron and free-electron sources, which suffer from relatively long pulse width or large time jitter, soft x-ray sources from HHG could offer attosecond time resolution and be synchronized with their driving field to investigate time-resolved near edge absorption spectroscopy, which could reveal rich structural and dynamical information of the interrogated samples. In this paper, we review recent progresses on generating and characterizing attosecond light sources in the water window region. We show our development of an energetic, two-cycle, carrier-envelope phase stable laser source at 1.7 μm and our achievement in producing a 53 as soft x-ray pulse covering the carbon K-edge in the water window. Such source paves the ways for the next generation x-ray spectroscopy with unprecedented temporal resolution.

  15. Chemical Dynamics at the Advanced Light Source

    International Nuclear Information System (INIS)

    Baer, T.; Berrah, N.; Fadley, C.; Moore, C.B.; Neumark, D.M.; Ng, C.Y.; Ruscic, B.; Smith, N.V.; Suits, A.G.; Wodtke, A.M.

    1999-01-01

    A day-long retreat was held January 15, 1999 to chart the future directions for chemical dynamics studies at the Advanced Light Source. This represents an important period for the Chemical Dynamics Beamline, as the hardware is well-developed, most of the initial experimental objectives have been realized and the mission is now to identify the future scientific priorities for the beamline and attract users of the highest caliber. To this end, we have developed a detailed scientific program for the near term; identified and prioritized the long range scientific opportunities, identified essential new hardware, and outlined an aggressive outreach program to involve the chemical physics community

  16. Magnet costs for the Advanced Light Source

    International Nuclear Information System (INIS)

    Tanabe, J.; Krupnick, J.; Hoyer, E.; Paterson, A.

    1993-05-01

    The Advanced Light Source (ALS) accelerator is now completed. The numerous conventional magnets required for the booster ring, the storage ring and the low and high energy transfer lines were installed during the last two years. This paper summarizes the various costs associated with the quantity fabrication of selected magnet families. These costs include the costs of prototypes, tooling, coil and core fabrication, assembly and magnetic measurements. Brief descriptions of the magnets and specialized requirements for magnetic measurements are included in order to associate the costs with the relative complexities of the various magnet systems

  17. Integrated source of broadband quadrature squeezed light

    DEFF Research Database (Denmark)

    Hoff, Ulrich Busk; Nielsen, Bo Melholt; Andersen, Ulrik Lund

    2015-01-01

    An integrated silicon nitride resonator is proposed as an ultracompact source of bright single-mode quadrature squeezed light at 850 nm. Optical properties of the device are investigated and tailored through numerical simulations, with particular attention paid to loss associated with interfacing...... the device. An asymmetric double layer stack waveguide geometry with inverse vertical tapers is proposed for efficient and robust fibre-chip coupling, yielding a simulated total loss of -0.75 dB/facet. We assess the feasibility of the device through a full quantum noise analysis and derive the output...

  18. Status of the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Galayda, John N.; /SLAC

    2011-11-04

    The Linac Coherent Light Source (LCLS) is a free electron laser facility in construction at Stanford Linear Accelerator Center. It is designed to operate in the wavelength range 0.15-1.5 nanometers. At the time of this conference, civil construction of new tunnels and buildings is complete, the necessary modifications to the SLAC linac are complete, and the undulator system and x-ray optics/diagnostics are being installed. The electron gun, 135 MeV injector linac and 250 MeV bunch compressor were commissioned in 2007. Accelerator commissioning activities are presently devoted to the achievement of performance goals for the completed 14 GeV linac.

  19. Aspects of a new light source

    International Nuclear Information System (INIS)

    Bagley, G.P.

    1978-01-01

    The National Synchrotron Light Source, under construction at Brookhaven Laboratory, will be a uniquely copious source of x-ray and ultraviolet photons with a wide spectrum. Some of the potential uses of this intense radiation include studies of absorption spectra, photo-emission of electrons, x-ray scattering, biochemical studies and other areas of basic research. It can also be used for micro-lithography of integrated circuits for ultra dense semiconductor devices. The basic operation of the electron synchrotron is described. This includes the three step acceleration of the electrons through a linear accelerator, a booster synchrotron and finally in a synchrotron storage ring. The synchrotron magnet power system, the responsibility of a black engineer, is described. An SCR chopper approach is used with precision components to achieve current stability and repeatability of 0.01 percent. This current generates the magnetic fields which bend and focus the electron beam

  20. Light extraction from luminescent light sources and application to monolithic ceramic phosphors.

    Science.gov (United States)

    Lenef, Alan; Kelso, John F; Piquette, Alan

    2014-05-15

    An extension of a theorem for light extraction [Adv. Opt. Technol.2, 291 (2013)] from a higher index luminescent body (LED or phosphor) through an extracting surface into a lower index output medium is derived. The result is valid for both geometric and diffractive surface structures. Using this bound and radiation transport calculations, we show that extraction from LEDs or phosphors requires a combination of cavity effects to enhance radiance behind the extracting surface and scattering or diffraction to couple trapped total-internal-reflection modes to propagating modes. The treatment applies to macroscopic luminescent sources whose thickness exceeds the longitudinal coherence length of the luminescent radiation.

  1. National Synchrotron Light Source annual report 1991

    International Nuclear Information System (INIS)

    Hulbert, S.L.; Lazarz, N.M.

    1992-04-01

    This report discusses the following research conducted at NSLS: atomic and molecular science; energy dispersive diffraction; lithography, microscopy and tomography; nuclear physics; UV photoemission and surface science; x-ray absorption spectroscopy; x-ray scattering and crystallography; x-ray topography; workshop on surface structure; workshop on electronic and chemical phenomena at surfaces; workshop on imaging; UV FEL machine reviews; VUV machine operations; VUV beamline operations; VUV storage ring parameters; x-ray machine operations; x-ray beamline operations; x-ray storage ring parameters; superconducting x-ray lithography source; SXLS storage ring parameters; the accelerator test facility; proposed UV-FEL user facility at the NSLS; global orbit feedback systems; and NSLS computer system

  2. National Synchrotron Light Source annual report 1991

    Energy Technology Data Exchange (ETDEWEB)

    Hulbert, S.L.; Lazarz, N.M. (eds.)

    1992-04-01

    This report discusses the following research conducted at NSLS: atomic and molecular science; energy dispersive diffraction; lithography, microscopy and tomography; nuclear physics; UV photoemission and surface science; x-ray absorption spectroscopy; x-ray scattering and crystallography; x-ray topography; workshop on surface structure; workshop on electronic and chemical phenomena at surfaces; workshop on imaging; UV FEL machine reviews; VUV machine operations; VUV beamline operations; VUV storage ring parameters; x-ray machine operations; x-ray beamline operations; x-ray storage ring parameters; superconducting x-ray lithography source; SXLS storage ring parameters; the accelerator test facility; proposed UV-FEL user facility at the NSLS; global orbit feedback systems; and NSLS computer system.

  3. A novel amblyopia treatment system based on LED light source

    Science.gov (United States)

    Zhang, Xiaoqing; Chen, Qingshan; Wang, Xiaoling

    2011-05-01

    A novel LED (light emitting diode) light source of five different colors (white, red, green, blue and yellow) is adopted instead of conventional incandescent lamps for an amblyopia treatment system and seven training methods for rectifying amblyopia are incorporated so as for achieving an integrated therapy. The LED light source is designed to provide uniform illumination, adjustable light intensity and alterable colors. Experimental tests indicate that the LED light source operates steadily and fulfills the technical demand of amblyopia treatment.

  4. EDITORIAL: Special Issue on Light Sources

    Science.gov (United States)

    Wharmby, D. O.

    2008-07-01

    The papers in this Special Issue of Journal of Physics D: Applied Physics originate from the 11th International Symposium on the Science and Technology of Light Sources (LS:11) held at Fudan University, Shanghai, China, during 20 24 May 2007. Abstracts of all papers were published in the conference book Light Sources 2007 (Sheffield: FAST-LS) edited by Muqing Liu and R Devonshire. Special issues were produced after LS:9 and LS:10 and have proved to be well-cited and important sources of information for this community. The Symposia occur at three-year intervals. In this one over 200 papers were presented—the majority as posters—with ample time provided for active discussion. As all submitted papers had to be refereed in the normal way for J. Phys. D: Appl. Phys., I was concerned that too many submissions would overwhelm the small number of referees available in this area. To ensure a broad spread of interests and opinions, I invited 10 senior colleagues to give me their recommendations about who should be asked to submit papers for this Special Issue. The criteria were that the work should be new, complete and within the scope of the journal. As a result of their suggestions 42 authors were asked to submit papers. Not all authors were able to submit a manuscript in time and some, at my request, combined their work into a single paper. The 28 papers published here are the result of that process. The issue starts with a comprehensive review by Benilov of the remarkable progress that has been made in the past 15 years in understanding the behaviour of cathode and anode terminations in arcs. It is fair to say that we now have a fundamental understanding of the formerly baffling behaviour of spot and diffuse terminations, at least in the quasi-steady state. A number of following papers cover applications of this theory, extensions to time dependence and examination of the effects of the different gaseous atmospheres in which lighting arcs operate. Mercury has very

  5. Improving the Efficiency of Solid State Light Sources

    International Nuclear Information System (INIS)

    Joanna McKittrick

    2003-01-01

    This proposal addresses the national need to develop a high efficiency light source for general illumination applications. The goal is to perform research that would lead to the fabrication of a unique solid state, white-emitting light source. This source is based on an InGaN/GaN UV-emitting chip that activates a luminescent material (phosphor) to produce white light. White-light LEDs are commercially available which use UV from a GaN chip to excite a phosphor suspended in epoxy around the chip. Currently, these devices are relatively inefficient. This research will target one technical barrier that presently limits the efficiency of GaN based devices. Improvements in efficiencies will be achieved by improving the internal conversion efficiency of the LED die, by improving the coupling between the die and phosphor(s) to reduce losses at the surfaces, and by selecting phosphors to maximize the emissions from the LEDs in conversion to white light. The UCSD research team proposes for this project to develop new phosphors that have high quantum efficiencies that can be activated by the UV-blue (360-410 nm) light emitted by the GaN device. The main goal for the UCSD team was to develop new phosphor materials with a very specific property: phosphors that could be excited at long UV-wavelengths (λ=350-410 nm). The photoluminescence of these new phosphors must be activated with photons emitted from GaN based dies. The GaN diodes can be designed to emit UV-light in the same range (λ=350-410 nm). A second objective, which is also very important, is to search for alternate methods to fabricate these phosphors with special emphasis in saving energy and time and reduce pollution

  6. Improving the Efficiency of Solid State Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Joanna McKittrick

    2003-03-31

    This proposal addresses the national need to develop a high efficiency light source for general illumination applications. The goal is to perform research that would lead to the fabrication of a unique solid state, white-emitting light source. This source is based on an InGaN/GaN UV-emitting chip that activates a luminescent material (phosphor) to produce white light. White-light LEDs are commercially available which use UV from a GaN chip to excite a phosphor suspended in epoxy around the chip. Currently, these devices are relatively inefficient. This research will target one technical barrier that presently limits the efficiency of GaN based devices. Improvements in efficiencies will be achieved by improving the internal conversion efficiency of the LED die, by improving the coupling between the die and phosphor(s) to reduce losses at the surfaces, and by selecting phosphors to maximize the emissions from the LEDs in conversion to white light. The UCSD research team proposes for this project to develop new phosphors that have high quantum efficiencies that can be activated by the UV-blue (360-410 nm) light emitted by the GaN device. The main goal for the UCSD team was to develop new phosphor materials with a very specific property: phosphors that could be excited at long UV-wavelengths ({lambda}=350-410 nm). The photoluminescence of these new phosphors must be activated with photons emitted from GaN based dies. The GaN diodes can be designed to emit UV-light in the same range ({lambda}=350-410 nm). A second objective, which is also very important, is to search for alternate methods to fabricate these phosphors with special emphasis in saving energy and time and reduce pollution.

  7. Intense X-ray and EUV light source

    Science.gov (United States)

    Coleman, Joshua; Ekdahl, Carl; Oertel, John

    2017-06-20

    An intense X-ray or EUV light source may be driven by the Smith-Purcell effect. The intense light source may utilize intense electron beams and Bragg crystals. This may allow the intense light source to range from the extreme UV range up to the hard X-ray range.

  8. Current capabilities at the Metrology Light Source

    International Nuclear Information System (INIS)

    Gottwald, Alexander; Klein, Roman; Mueller, Ralph; Richter, Mathias; Scholze, Frank; Thornagel, Reiner; Ulm, Gerhard

    2012-01-01

    The Physikalisch-Technische Bundesanstalt (PTB) has set up the 630 MeV electron storage ring Metrology Light Source (MLS) in close cooperation with the Helmholtz-Zentrum Berlin (HZB). This electron storage ring has been in regular user operation since April 2008. It is dedicated to synchrotron-radiation-based metrology and technological developments in the far-IR/THz, IR, UV, VUV and EUV spectral ranges, with the use as primary source standard as the key activity. In a permanent process of improvement, the storage ring itself was optimized regarding its regular performance (beam current and lifetime) as well as for special operations (e.g. variable electron energies and electron bunch lengths). The measurement capabilities at the seven different beamline ports were set up sequentially, first in the UV/VUV and IR spectral ranges. This first phase of instrumentation set-up will be finished in 2011 by completing the beamlines for EUV metrology, for the calibration of radiation sources and for the application of undulator radiation. (authors)

  9. Phosphor converted laser diode light source for endoscopic diagnostics

    DEFF Research Database (Denmark)

    Krasnoshchoka, Anastasiia; Thorseth, Anders; Dam-Hansen, Carsten

    2017-01-01

    In order to provide light sources for endourology and on-site testing of the light source, we are developing a portable endoscope light source prototype based on a phosphor converted laser diode. A small emitting area from the phosphor material excited by a laser diode enables coupling...... of the generated white light into thin optical fibres. The development involves designing optics for optimizing the light extraction efficiency and guiding of light to the area of interest. In this paper we compared the developed light source to the current standard in endoscopy – xenon arc lamps. Detailed...... spectral analysis of illuminance, CRI and CCT at two power levels and two distances for both the PC-LD and the xenon light source was performed. The obtained results verified that the developed light source is suitable for endoscopy illumination and the first pre-clinical trials will be performed shortly....

  10. Design, commissioning and operation of the Swiss Light Source SLS

    International Nuclear Information System (INIS)

    Streun, Andreas

    2003-01-01

    The Swiss Light Source (SLS) at the Paul Scherrer Institute (PSI) is the most recent 3rd generation light source coming to operation. It consists of a 12- TBA storage ring of 288 m circumference providing 5 nm rad emittance at 2.4 GeV, a novel type of full energy booster synchrotron and a 100 MeV linac. The initial four beamlines cover protein X-ray crystallography (PX), materials science (MS), surface and interface spectroscopy (SIS) and microscopy (SIM). We will review the project history, describe the design concepts of the accelerators and the technical subsystems, and report on the commissioning process and the status of operation by end of 2002. (author)

  11. Determination of illuminants representing typical white light emitting diodes sources

    DEFF Research Database (Denmark)

    Jost, S.; Ngo, M.; Ferrero, A.

    2017-01-01

    Solid-state lighting (SSL) products are already in use by consumers and are rapidly gaining the lighting market. Especially, white Light Emitting Diode (LED) sources are replacing banned incandescent lamps and other lighting technologies in most general lighting applications. The aim of this work...

  12. Energy Recovery Linacs for Light Source Applications

    Energy Technology Data Exchange (ETDEWEB)

    George Neil

    2011-04-01

    Energy Recovery Linacs are being considered for applications in present and future light sources. ERLs take advantage of the continuous operation of superconducting rf cavities to accelerate high average current beams with low losses. The electrons can be directed through bends, undulators, and wigglers for high brightness x ray production. They are then decelerated to low energy, recovering power so as to minimize the required rf drive and electrical draw. When this approach is coupled with advanced continuous wave injectors, very high power, ultra-short electron pulse trains of very high brightness can be achieved. This paper will review the status of worldwide programs and discuss the technology challenges to provide such beams for photon production.

  13. Status of the CAMD Light Source

    CERN Document Server

    Suller, Victor P; Fedurin, Mikhail; Jines, Paul; Launey, Daren; Miller, Toby; Wang, Yanshan

    2005-01-01

    With the increasing diversity of its research program, the CAMD Light Source has improved its beam brightness and quality. Using a well calibrated model of the lattice, the ring optic has been refined to generate a lower beam emittance of 150 nm.rad and this has been confirmed by measuring the beta values with the modulated quadrupole shunt system. The beam sizes have also been measured with an X-ray pinhole camera and compared to the calculated emittance. The beam orbit is corrected to a standard position referenced to the quadrupole centers to a precision better than 0.5 mm, using a suite of well localized bumps which can also flexibly steer the user photon beams to their requirements. Beam reliability has been improved by bringing into use a VME control system for the energy ramp.

  14. The advanced light source control system

    International Nuclear Information System (INIS)

    Magyary, S.; Chin, M.; Cork, C.; Fahmie, M.; Lancaster, H.; Molinari, P.; Ritchie, A.; Robb, A.; Timossi, C.; Young, J.

    1990-01-01

    The criteria for the design of a modern control system are discussed in the context of the special requirements for the control of the Advanced Light Source (ALS). This is followed by the description of the system being built, which has a number of special features. The emphasis has been placed on providing an extremely wide I/O and CPU bandwidth (greater than 120 Mbits/s and 1200 Mips, respectively) and on using commercially available hardware and software. The only major custom design item is the Intelligent Local Controller (ILC), of which about 600 will be used to interface to the hardware. The use of personal computers for the operator stations allows the use of a wealth of industrial standards for windows, languages and tools. (orig.)

  15. LED intense headband light source for fingerprint analysis

    Science.gov (United States)

    Villa-Aleman, Eliel

    2005-03-08

    A portable, lightweight and high-intensity light source for detecting and analyzing fingerprints during field investigation. On-site field analysis requires long hours of mobile analysis. In one embodiment, the present invention comprises a plurality of light emitting diodes; a power source; and a personal attachment means; wherein the light emitting diodes are powered by the power source, and wherein the power source and the light emitting diodes are attached to the personal attachment means to produce a personal light source for on-site analysis of latent fingerprints. The present invention is available for other applications as well.

  16. Leveraging brightness from transportation lighting systems through light source color.

    Science.gov (United States)

    2013-11-01

    Roadway transportation lighting is installed for multiple reasons including traffic safety and pedestrian : security. Judgments of pedestrian safety and security along roadways are not strictly correlated to : specified light levels, but the color of...

  17. All fiber based supercontinuum light source utilized for IR microscopy

    DEFF Research Database (Denmark)

    Dupont, Sune; Petersen, Christian; Thøgersen, Jan

    2012-01-01

    An all fiber based supercontinuum light source is demonstrated for infrared microscopy. The high brightness and spatial coherence of the source facilitate fast high resolution measurements.......An all fiber based supercontinuum light source is demonstrated for infrared microscopy. The high brightness and spatial coherence of the source facilitate fast high resolution measurements....

  18. National Synchrotron Light Source 2008 Activity Report

    International Nuclear Information System (INIS)

    Nasta, K.

    2009-01-01

    Funded by the U.S. Department of Energy's Office of Basic Energy Sciences, the National Synchrotron Light Source (NSLS) is a national user facility that operates two electron storage rings: X-Ray (2.8 GeV, 300 mA) and Vacuum Ultraviolet (VUV) (800 mev, 1.0A). These two rings provide intense light spanning the electromagnetic spectrum -- from very long infrared rays to ultraviolet light and super-short x-rays -- to analyze very small or highly dilute samples. The properties of this light, and the specially designed experimental stations, called beamlines, allow scientists in many diverse disciplines of research to perform experiments not possible at their own laboratories. Each year, about 2,200 scientists from more than 400 universities and companies use the NSLS for research in such diverse fields as biology, physics, chemistry, geology, medicine, and environmental and materials sciences. For example, researchers have used the NSLS to examine the minute details of computer chips, decipher the structures of viruses, probe the density of bone, determine the chemical composition of moon rocks, and reveal countless other mysteries of science. The facility has 65 operating beamlines, with 51 beamlines on the X-Ray Ring and 14 beamlines on the VUV-Infrared Ring. It runs seven days a week, 24 hours a day throughout the year, except during periods of maintenance and studies. Researchers are not charged for beam time, provided that the research results are published in open literature. Proprietary research is conducted on a full-cost-recovery basis. With close to 1,000 publications per year, the NSLS is one of the most prolific scientific facilities in the world. Among the many accolades given to its users and staff, the NSLS has won nine R and D 100 Awards for innovations ranging from a closed orbit feedback system to the first device able to focus a large spread of high-energy x-rays. In addition, a visiting NSLS researcher shared the 2003 Nobel Prize in Chemistry for

  19. National Synchrotron Light Source 2008 Activity Report

    Energy Technology Data Exchange (ETDEWEB)

    Nasta,K.

    2009-05-01

    Funded by the U.S. Department of Energy's Office of Basic Energy Sciences, the National Synchrotron Light Source (NSLS) is a national user facility that operates two electron storage rings: X-Ray (2.8 GeV, 300 mA) and Vacuum Ultraviolet (VUV) (800 mev, 1.0A). These two rings provide intense light spanning the electromagnetic spectrum -- from very long infrared rays to ultraviolet light and super-short x-rays -- to analyze very small or highly dilute samples. The properties of this light, and the specially designed experimental stations, called beamlines, allow scientists in many diverse disciplines of research to perform experiments not possible at their own laboratories. Each year, about 2,200 scientists from more than 400 universities and companies use the NSLS for research in such diverse fields as biology, physics, chemistry, geology, medicine, and environmental and materials sciences. For example, researchers have used the NSLS to examine the minute details of computer chips, decipher the structures of viruses, probe the density of bone, determine the chemical composition of moon rocks, and reveal countless other mysteries of science. The facility has 65 operating beamlines, with 51 beamlines on the X-Ray Ring and 14 beamlines on the VUV-Infrared Ring. It runs seven days a week, 24 hours a day throughout the year, except during periods of maintenance and studies. Researchers are not charged for beam time, provided that the research results are published in open literature. Proprietary research is conducted on a full-cost-recovery basis. With close to 1,000 publications per year, the NSLS is one of the most prolific scientific facilities in the world. Among the many accolades given to its users and staff, the NSLS has won nine R&D 100 Awards for innovations ranging from a closed orbit feedback system to the first device able to focus a large spread of high-energy x-rays. In addition, a visiting NSLS researcher shared the 2003 Nobel Prize in Chemistry for

  20. Diamond Light Source: status and perspectives.

    Science.gov (United States)

    Materlik, Gerhard; Rayment, Trevor; Stuart, David I

    2015-03-06

    Diamond Light Source, a third-generation synchrotron radiation (SR) facility in the UK, celebrated its 10th anniversary in 2012. A private limited company was set up in April 2002 to plan, construct and operate the new user-oriented SR facility, called in brief Diamond. It succeeded the Synchrotron Radiation Source in Daresbury, a second-generation synchrotron that opened in 1980 as the world's first dedicated X-ray-providing facility, closing finally in 2008, by which time Diamond's accelerators and first beamlines were operating and user experiments were under way. This theme issue of Philosophical Transactions of the Royal Society A gives some examples of the rich diversity of research done in the initial five years, with some glimpses of activity up to 2014. Speakers at the 10 year anniversary symposium were drawn from a small number of major thematic areas and each theme was elaborated by a few speakers whose contributions were placed into a broader context by a leading member of the UK academic community in the role of rapporteur. This introduction gives a summary of the design choices and strategic planning of Diamond as a coherent user facility, a snapshot of its present status and some consideration of future perspectives. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  1. The 4th Generation Light Source at Jefferson Lab

    Energy Technology Data Exchange (ETDEWEB)

    Stephen Benson; George Biallas; James Boyce; Donald Bullard; James Coleman; David Douglas; H. Dylla; Richard Evans; Pavel Evtushenko; Albert Grippo; Christopher Gould; Joseph Gubeli; David Hardy; Carlos Hernandez-Garcia; Kevin Jordan; John Klopf; Steven Moore; George Neil; Thomas Powers; Joseph Preble; Daniel Sexton; Michelle D. Shinn; Christopher Tennant; Richard Walker; Shukui Zhang; Gwyn Williams

    2007-04-25

    A number of "Grand Challenges" in Science have recently been identified in reports from The National Academy of Sciences, and the U.S. Dept. of Energy, Basic Energy Sciences. Many of these require a new generation of linac-based light source to study dynamical and non-linear phenomena in nanoscale samples. In this paper we present a summary of the properties of such light sources, comparing them with existing sources, and then describing in more detail a specific source at Jefferson Lab. Importantly, the JLab light source has developed some novel technology which is a critical enabler for other new light sources.

  2. The 4th Generation Light Source at Jefferson Lab

    International Nuclear Information System (INIS)

    Stephen Benson; George Biallas; James Boyce; Donald Bullard; James Coleman; David Douglas; H. Dylla; Richard Evans; Pavel Evtushenko; Albert Grippo; Christopher Gould; Joseph Gubeli; David Hardy; Carlos Hernandez-Garcia; Kevin Jordan; John Klopf; Steven Moore; George Neil; Thomas Powers; Joseph Preble; Daniel Sexton; Michelle Shinn; Christopher Tennant; Richard Walker; Shukui Zhang; Gwyn Williams

    2007-01-01

    A number of 'Grand Challenges' in Science have recently been identified in reports from The National Academy of Sciences, and the U.S. Dept. of Energy, Basic Energy Sciences. Many of these require a new generation of linac-based light source to study dynamical and non-linear phenomena in nanoscale samples. In this paper we present a summary of the properties of such light sources, comparing them with existing sources, and then describing in more detail a specific source at Jefferson Lab. Importantly, the JLab light source has developed some novel technology which is a critical enabler for other new light sources

  3. The Jefferson Lab High Power Light Source

    International Nuclear Information System (INIS)

    Jefferson Lab has designed, built and operated two high average power free-electron lasers (FEL) using superconducting RF (SRF) technology and energy recovery techniques. Between 1999-2001 Jefferson Lab operated the IR Demo FEL. This device produced over 2 kW in the mid-infrared, in addition to producing world record average powers in the visible (50 W), ultraviolet (10 W) and terahertz range (50 W) for tunable, short-pulse (< ps) light. This FEL was the first high power demonstration of an accelerator configuration that is being exploited for a number of new accelerator-driven light source facilities that are currently under design or construction. The driver accelerator for the IR Demo FEL uses an Energy Recovered Linac (ERL) configuration that improves the energy efficiency and lowers both the capital and operating cost of such devices by recovering most of the power in the spent electron beam after optical power is extracted from the beam. The IR Demo FEL was de-commissioned in late 2001 for an upgraded FEL for extending the IR power to over 10 kW and the ultraviolet power to over 1 kW. The FEL Upgrade achieved 10 kW of average power in the mid-IR (6 microns) in July of 2004, and its IR operation currently is being extended down to 1 micron. In addition, we have demonstrated the capability of on/off cycling and recovering over a megawatt of electron beam power without diminishing machine performance. A complementary UV FEL will come on-line within the next year. This paper presents a summary of the FEL characteristics, user community accomplishments with the IR Demo, and planned user experiments

  4. The Jefferson Lab High Power Light Source

    Energy Technology Data Exchange (ETDEWEB)

    James R. Boyce

    2006-01-01

    Jefferson Lab has designed, built and operated two high average power free-electron lasers (FEL) using superconducting RF (SRF) technology and energy recovery techniques. Between 1999-2001 Jefferson Lab operated the IR Demo FEL. This device produced over 2 kW in the mid-infrared, in addition to producing world record average powers in the visible (50 W), ultraviolet (10 W) and terahertz range (50 W) for tunable, short-pulse (< ps) light. This FEL was the first high power demonstration of an accelerator configuration that is being exploited for a number of new accelerator-driven light source facilities that are currently under design or construction. The driver accelerator for the IR Demo FEL uses an Energy Recovered Linac (ERL) configuration that improves the energy efficiency and lowers both the capital and operating cost of such devices by recovering most of the power in the spent electron beam after optical power is extracted from the beam. The IR Demo FEL was de-commissioned in late 2001 for an upgraded FEL for extending the IR power to over 10 kW and the ultraviolet power to over 1 kW. The FEL Upgrade achieved 10 kW of average power in the mid-IR (6 microns) in July of 2004, and its IR operation currently is being extended down to 1 micron. In addition, we have demonstrated the capability of on/off cycling and recovering over a megawatt of electron beam power without diminishing machine performance. A complementary UV FEL will come on-line within the next year. This paper presents a summary of the FEL characteristics, user community accomplishments with the IR Demo, and planned user experiments.

  5. Photocathodes for High Repetition Rate Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Zvi, Ilan [Stony Brook Univ., NY (United States). Dept. of Physics and Astronomy. Center for Accelerator Science and Education

    2014-04-20

    This proposal brought together teams at Brookhaven National Laboratory (BNL), Lawrence Berkeley National Laboratory (LBNL) and Stony Brook University (SBU) to study photocathodes for high repetition rate light sources such as Free Electron Lasers (FEL) and Energy Recovery Linacs (ERL). Below details the Principal Investigators and contact information. Each PI submits separately for a budget through his corresponding institute. The work done under this grant comprises a comprehensive program on critical aspects of the production of the electron beams needed for future user facilities. Our program pioneered in situ and in operando diagnostics for alkali antimonide growth. The focus is on development of photocathodes for high repetition rate Free Electron Lasers (FELs) and Energy Recovery Linacs (ERLs), including testing SRF photoguns, both normal-­conducting and superconducting. Teams from BNL, LBNL and Stony Brook University (SBU) led this research, and coordinated their work over a range of topics. The work leveraged a robust infrastructure of existing facilities and the support was used for carrying out the research at these facilities. The program concentrated in three areas: a) Physics and chemistry of alkali-­antimonide cathodes (BNL – LBNL) b) Development and testing of a diamond amplifier for photocathodes (SBU -­ BNL) c) Tests of both cathodes in superconducting RF photoguns (SBU) and copper RF photoguns (LBNL) Our work made extensive use of synchrotron radiation materials science techniques, such as powder-­ and single-­crystal diffraction, x-­ray fluorescence, EXAFS and variable energy XPS. BNL and LBNL have many complementary facilities at the two light sources associated with these laboratories (NSLS and ALS, respectively); use of these will be a major thrust of our program and bring our understanding of these complex materials to a new level. In addition, CHESS at Cornell will be used to continue seamlessly throughout the NSLS dark period and

  6. Estimation of light source colours for light pollution assessment.

    Science.gov (United States)

    Ziou, D; Kerouh, F

    2018-05-01

    The concept of the smart city raised several technological and scientific issues including light pollution. There are various negative impacts of light pollution on economy, ecology, and heath. This paper deals with the census of the colour of light emitted by lamps used in a city environment. To this end, we derive a light bulb colour estimator based on Bayesian reasoning, directional data, and image formation model in which the usual concept of reflectance is not used. All choices we made are devoted to designing an algorithm which can be run almost in real-time. Experimental results show the effectiveness of the proposed approach. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. First undulators for the Advanced Light Source

    International Nuclear Information System (INIS)

    Hoyer, E.; Akre, J.; Chin, J.

    1993-05-01

    The first three undulators, each 4.6 m in length, for the Advanced Light source (ALS) at Lawrence Berkeley Laboratory (LBL), are near completion and are undergoing qualification tests before installation into the storage ring. Two devices have 5.0-cm period lengths, 89 periods, and achieve an effective field of 0.85 T at the 14 mm minimum magnetic gap. The other device has a period length of 8.0 cm, 55 periods, and an effective field of 1.2 T at the minimum 14 mm gap. Measurements on the first 5 cm period device show the uncorrelated field errors to be 0.23%, which is less than the required 0.25%. Measurements of gap control show reproducibility of ±5 microns or better. The first vacuum chamber, 5.0 m long, is flat to within 0.53 mm over the 4.6 m magnetic structure section and a 4 x 10 -11 Torr pressure was achieved during vacuum tests. Device description, fabrication, and measurements are presented

  8. The Injection System of SAGA Light Source

    CERN Document Server

    Iwasaki, Yoshitaka; Ohgaki, Hideaki; Okajima, Toshihiro; Takabayashi, Yuichi; Tomimasu, Takio; Yoshida, Katuhide

    2005-01-01

    Saga light Source is a 1.4-GeV electron storage ring with a circumference of 75.6m. The injector is a 250-MeV linac producing 1 ms macro-pulse with a peak current of 12mA and repetition rate of 1Hz. The output beam from the linac is transported though a transport line, and injected into the ring though a septum magnet with a bending angle of 20-degree. The transport line consists of two bending magnets, two quadrupole doublelets, and a quadrupole singlet. The bump orbit is formed by four kicker magnets, two of which are installed at both sides of septum magnet, and other two are positioned apart by one magnet cell of the ring. They are excited by sinusoidal electric currents with a half width of 0.5 ms. The beam optics for the injection trajectory is computed and shown at control room, the parameters for which are provided directly from the power supply control server PC. The operator is able to see real-time result of the beam trajectory calculation. This tool is quite effective to optimize the magnets param...

  9. National Synchrotron Light Source 2010 Activity Report

    International Nuclear Information System (INIS)

    Rowe, M.; Snyder, K.J.

    2010-01-01

    This is a very exciting period for photon sciences at Brookhaven National Laboratory. It is also a time of unprecedented growth for the Photon Sciences Directorate, which operates the National Synchrotron Light Source (NSLS) and is constructing NSLS-II, both funded by the Department of Energy's Office of Science. Reflecting the quick pace of our activities, we chose the theme 'Discovery at Light Speed' for the directorate's 2010 annual report, a fiscal year bookended by October 2009 and September 2010. The year began with the news that NSLS users Venki Ramakrishnan of Cambridge University (also a former employee in Brookhaven's biology department) and Thomas A. Steitz of Yale University were sharing the 2009 Nobel Prize in Chemistry with Ada E. Yonath of the Weizmann Institute of Science. Every research project has the potential for accolades. In 2010, NSLS users and staff published close to 900 papers, with about 170 appearing in premiere journals. Those are impressive stats for a facility nearly three decades old, testament to the highly dedicated team keeping NSLS at peak performance and the high quality of its user community. Our NSLS users come from a worldwide community of scientists using photons, or light, to carry out research in energy and environmental sciences, physics, materials science, chemistry, biology and medicine. All are looking forward to the new capabilities enabled by NSLS-II, which will offer unprecedented resolution at the nanoscale. The new facility will produce x-rays more than 10,000 times brighter than the current NSLS and host a suite of sophisticated instruments for cutting-edge science. Some of the scientific discoveries we anticipate at NSLS-II will lead to major advances in alternative energy technologies, such as hydrogen and solar. These discoveries could pave the way to: (1) catalysts that split water with sunlight for hydrogen production; (2) materials that can reversibly store large quantities of electricity or hydrogen; (3

  10. National Synchrotron Light Source 2010 Activity Report

    Energy Technology Data Exchange (ETDEWEB)

    Rowe, M.; Snyder, K. J.

    2010-12-29

    This is a very exciting period for photon sciences at Brookhaven National Laboratory. It is also a time of unprecedented growth for the Photon Sciences Directorate, which operates the National Synchrotron Light Source (NSLS) and is constructing NSLS-II, both funded by the Department of Energy's Office of Science. Reflecting the quick pace of our activities, we chose the theme 'Discovery at Light Speed' for the directorate's 2010 annual report, a fiscal year bookended by October 2009 and September 2010. The year began with the news that NSLS users Venki Ramakrishnan of Cambridge University (also a former employee in Brookhaven's biology department) and Thomas A. Steitz of Yale University were sharing the 2009 Nobel Prize in Chemistry with Ada E. Yonath of the Weizmann Institute of Science. Every research project has the potential for accolades. In 2010, NSLS users and staff published close to 900 papers, with about 170 appearing in premiere journals. Those are impressive stats for a facility nearly three decades old, testament to the highly dedicated team keeping NSLS at peak performance and the high quality of its user community. Our NSLS users come from a worldwide community of scientists using photons, or light, to carry out research in energy and environmental sciences, physics, materials science, chemistry, biology and medicine. All are looking forward to the new capabilities enabled by NSLS-II, which will offer unprecedented resolution at the nanoscale. The new facility will produce x-rays more than 10,000 times brighter than the current NSLS and host a suite of sophisticated instruments for cutting-edge science. Some of the scientific discoveries we anticipate at NSLS-II will lead to major advances in alternative energy technologies, such as hydrogen and solar. These discoveries could pave the way to: (1) catalysts that split water with sunlight for hydrogen production; (2) materials that can reversibly store large quantities of

  11. Light emitting diodes as a plant lighting source

    Energy Technology Data Exchange (ETDEWEB)

    Bula, R.J.; Tennessen, D.J.; Morrow, R.C. [Wisconsin Center for Space Automation and Robotics, Madison, WI (United States); Tibbitts, T.W. [Univ. of Wisconsin, Madison, WI (United States)

    1994-12-31

    Electroluminescence in solid materials is defined as the generation of light by the passage of an electric current through a body of solid material under an applied electric field. A specific type of electroluminescence, first noted by Lossew in 1923, involves the generation of photons when electrons are passed through a p-n junction of certain solid materials (junction of a n-type semiconductor, an electron donor, and a p-type semiconductor, an electron acceptor). Development efforts to translate these observations into visible light emitting devices, however, was not undertaken until the 1950s. The term, light emitting diode (LEDs), was first used in a report by Wolfe, et al., in 1955. The development of this light emitting semiconductor technology dates back less than 30 years. During this period of time, the LED has evolved from a rare and expensive light generating device to one of the most widely used electronic components. The most popular applications of the LED are as indicators or as optoelectronic switches. However, several recent advances in LED technology have made possible the utilization of LEDs for applications that require a high photon flux, such as for plant lighting in controlled environments. The new generation of LEDs based on a gallium aluminum arsenide (GaAlAS) semiconductor material fabricated as a double heterostructure on a transparent substrate has opened up many new applications for these LEDs.

  12. Light, shadows and surface characteristics: the multispectral Portable Light Dome

    Science.gov (United States)

    Watteeuw, Lieve; Hameeuw, Hendrik; Vandermeulen, Bruno; Van der Perre, Athena; Boschloos, Vanessa; Delvaux, Luc; Proesmans, Marc; Van Bos, Marina; Van Gool, Luc

    2016-11-01

    A multispectral, multidirectional, portable and dome-shaped acquisition system is developed within the framework of the research projects RICH (KU Leuven) and EES (RMAH, Brussels) in collaboration with the ESAT-VISICS research group (KU Leuven). The multispectral Portable Light Dome (MS PLD) consists of a hemispherical structure, an overhead camera and LEDs emitting in five parts of the electromagnetic spectrum regularly covering the dome's inside surface. With the associated software solution, virtual relighting and enhancements can be applied in a real-time, interactive manner. The system extracts genuine 3D and shading information based on a photometric stereo algorithm. This innovative approach allows for instantaneous alternations between the computations in the infrared, red, green, blue and ultraviolet spectra. The MS PLD system has been tested for research ranging from medieval manuscript illuminations to ancient Egyptian artefacts. Preliminary results have shown that it documents and measures the 3D surface structure of objects, re-visualises underdrawings, faded pigments and inscriptions, and examines the MS results in combination with the actual relief characteristics of the physical object. Newly developed features are reflection maps and histograms, analytic visualisations of the reflection properties of all separate LEDs or selected areas. In its capacity as imaging technology, the system acts as a tool for the analysis of surface materials (e.g. identification of blue pigments, gold and metallic surfaces). Besides offering support in answering questions of attribution and monitoring changes and decay of materials, the PLD also contributes to the identification of materials, all essential factors when making decisions in the conservation protocol.

  13. Investigation of Light-Emitting Diode (LED) Point Light Source Color Visibility against Complex Multicolored Backgrounds

    Science.gov (United States)

    2017-11-01

    ARL-TR-8214 ● NOV 2017 US Army Research Laboratory Investigation of Light-Emitting Diode (LED) Point Light Source Color...ARL-TR-8214 ● NOV 2017 US Army Research Laboratory Investigation of Light-Emitting Diode (LED) Point Light Source Color Visibility against...instructions, searching existing data sources , gathering and maintaining the data needed, and completing and reviewing the collection information. Send

  14. Barium light source method and apparatus

    Science.gov (United States)

    Curry, John J. (Inventor); MacDonagh-Dumler, Jeffrey (Inventor); Anderson, Heidi M. (Inventor); Lawler, James E. (Inventor)

    2002-01-01

    Visible light emission is obtained from a plasma containing elemental barium including neutral barium atoms and barium ion species. Neutral barium provides a strong green light emission in the center of the visible spectrum with a highly efficient conversion of electrical energy into visible light. By the selective excitation of barium ionic species, emission of visible light at longer and shorter wavelengths can be obtained simultaneously with the green emission from neutral barium, effectively providing light that is visually perceived as white. A discharge vessel contains the elemental barium and a buffer gas fill therein, and a discharge inducer is utilized to induce a desired discharge temperature and barium vapor pressure therein to produce from the barium vapor a visible light emission. The discharge can be induced utilizing a glow discharge between electrodes in the discharge vessel as well as by inductively or capacitively coupling RF energy into the plasma within the discharge vessel.

  15. Optical surfacing via linear ion source

    International Nuclear Information System (INIS)

    Wu, Lixiang; Wei, Chaoyang; Shao, Jianda

    2017-01-01

    We present a concept of surface decomposition extended from double Fourier series to nonnegative sinusoidal wave surfaces, on the basis of which linear ion sources apply to the ultra-precision fabrication of complex surfaces and diffractive optics. The modified Fourier series, or sinusoidal wave surfaces, build a relationship between the fabrication process of optical surfaces and the surface characterization based on power spectral density (PSD) analysis. Also, we demonstrate that the one-dimensional scanning of linear ion source is applicable to the removal of mid-spatial frequency (MSF) errors caused by small-tool polishing in raster scan mode as well as the fabrication of beam sampling grating of high diffractive uniformity without a post-processing procedure. The simulation results show that optical fabrication with linear ion source is feasible and even of higher output efficiency compared with the conventional approach.

  16. National Synchrotron Light Source: vacuum system for National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Schuchman, J.C.; Godel, J.B.; Jordan, W.; Oversluizen, T.

    1978-01-01

    The National Synchrotron Light Source (NSLS), a 24 million dollar project under construction at Brookhaven National Laboratory (BNL), is a research facility dedicated to the production of synchrotron radiation. Synchrotron radiation is that radiation produced by the acceleration of charged particles at near the speed of light. This facility will provide a continuous spectrum of radiation from the vacuum ultraviolet to the hard x-ray range. The radiation will be highly intense, 100% polarized, extremely well collimated and will have a pulsed time structure. The radiation will be produced in two electron storage rings at energies of 700 MeV and 2.5 GeV, respectively. A maximum of one ampere at 2 GeV, or one-half ampere at 2.5 GeV, of electron beam will be stored

  17. LAT Monitored Source List Light Curves

    Data.gov (United States)

    National Aeronautics and Space Administration — The LAT team monitors flux values for a number of bright sources and transient sources that have shown flares during the mission. (See up-to-date weekly reports on...

  18. Synchrotron light sources: A powerful tool for science and technology

    International Nuclear Information System (INIS)

    Schlachter, F.; Robinson, A.

    1996-01-01

    A new generation of synchrotron light sources is producing extremely bright beams of vacuum-ultraviolet and x-ray radiation, powerful new tools for research in a wide variety of basic and applied sciences. Spectromicroscopy using high spectral and spatial resolution is a new way of seeing, offering many opportunities in the study of matter. Development of a new light source provides the country or region of the world in which the light source is located many new opportunities: a focal point for research in many scientific and technological areas, a means of upgrading the technology infrastructure of the country, a means of training students, and a potential service to industry. A light source for Southeast Asia would thus be a major resource for many years. Scientists and engineers from light sources around the world look forward to providing assistance to make this a reality in Southeast Asia

  19. Synchrotron light sources: A powerful tool for science and technology

    International Nuclear Information System (INIS)

    Schlachter, F.; Robinson, A.

    1996-01-01

    A new generation of synchrotron light sources is producing extremely bright beams of vacuum-ultraviolet and x-ray radiation, poweful new tools for research in a wide variety of basic and applied sciences. Spectromicroscopy using high spectral and spatial resolution is a new way of seeing, offering many opportunities in the study of matter. Development of a new light source provides the country or region of the world in which the light source is located many new opportunities: a focal point for research in many scientific and technological areas, a means of upgrading the technology infrastructure of the country, a means of training students, and a potential service to industry. A light source for Southeast Asia would thus be a major resource for many years. Scientists and engineers from light sources around the world look forward to providing assistance to make this a reality in Southeast Asia

  20. Water cooled metal optics for the Advanced Light Source

    International Nuclear Information System (INIS)

    McKinney, W.R.; Irick, S.C.; Lunt, D.L.J.

    1991-01-01

    The program for providing water cooled metal optics for the Advanced Light Source at Berkeley is reviewed with respect to fabrication and metrology of the surfaces. Materials choices, surface figure and smoothness specifications, and metrology systems for measuring the plated metal surfaces are discussed. Results from prototype mirrors and grating blanks will be presented, which show exceptionally low microroughness and mid-period error. We will briefly describe out improved version of the Long Trace Profiler, and its importance to out metrology program. We have completely redesigned the mechanical, optical and computational parts of the profiler system with the cooperation of Peter Takacs of Brookhaven, Continental Optical, and Baker Manufacturing. Most important is that one of our profilers is in use at the vendor to allow testing during fabrication. Metrology from the first water cooled mirror for an ALS beamline is presented as an example. The preplating processing and grinding and polishing were done by Tucson Optical. We will show significantly better surface microroughness on electroless nickel, over large areas, than has been reported previously

  1. Water cooled metal optics for the Advanced Light Source

    International Nuclear Information System (INIS)

    McKinney, W.R.; Irick, S.C.; Lunt, D.L.J.

    1992-01-01

    The program for providing water cooled metal optics for the Advanced Light Source at Berkeley is reviewed with respect to fabrication and metrology of the surfaces. Materials choices, surface figure and smoothness specifications, and metrology systems for measuring the plated metal surfaces are discussed. Results from prototype mirrors and grating blanks will be presented, which show exceptionally low microroughness and midperiod error. We will briefly describe our improved version of the long trace profiler, and its importance to our metrology program. We have completely redesigned the mechanical, optical and computational parts of the profiler system with the cooperation of P. Takacs of Brookhaven, Continental Optical, and Baker Manufacturing. Most important is that one of our profilers is in use at the vendor to allow testing during fabrication. Metrology from the first water cooled mirror for an ALS beamline is presented as an example. This 15 in. long Glidcop T M mirror is coated with electroless nickel from Acteron Corporation in Redwood City, CA. The preplating processing and grinding and polishing were done by Tucson Optical. We will show significantly better surface microroughness on electroless nickel, over large areas, than has been reported previously. (orig.)

  2. Micro optical fiber light source and sensor and method of fabrication thereof

    Science.gov (United States)

    Kopelman, Raoul; Tan, Weihong; Shi, Zhong-You

    1994-01-01

    This invention relates generally to the development of and a method of fabricating a micro optical fiber light source. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications.

  3. A new storage-ring light source

    Energy Technology Data Exchange (ETDEWEB)

    Chao, Alex [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-06-01

    A recently proposed technique in storage ring accelerators is applied to provide potential high-power sources of photon radiation. The technique is based on the steady-state microbunching (SSMB) mechanism. As examples of this application, one may consider a high-power DUV photon source for research in atomic and molecular physics or a high-power EUV radiation source for industrial lithography. A less challenging proof-of-principle test to produce IR radiation using an existing storage ring is also considered.

  4. An experiment on the color rendering of different light sources

    Science.gov (United States)

    Fumagalli, Simonetta; Bonanomi, Cristian; Rizzi, Alessandro

    2013-02-01

    The color rendering index (CRI) of a light source attempts to measure how much the color appearance of objects is preserved when they are illuminated by the given light source. This problem is of great importance for various industrial and scientific fields, such as lighting architecture, design, ergonomics, etc. Usually a light source is specified through the Correlated Color Temperature or CCT. However two (or more) light sources with the same CCT but different spectral power distribution can exist. Therefore color samples viewed under two light sources with equal CCTs can appear different. Hence, the need for a method to assess the quality of a given illuminant in relation to color. Recently CRI has had a renewed interest because of the new LED-based lighting systems. They usually have a color rendering index rather low, but good preservation of color appearance and a pleasant visual appearance (visual appeal). Various attempts to develop a new color rendering index have been done so far, but still research is working for a better one. This article describes an experiment performed by human observers concerning the appearance preservation of color under some light sources, comparing it with a range of available color rendering indices.

  5. Workshop on scientific applications of short wavelength coherent light sources

    International Nuclear Information System (INIS)

    Spicer, W.; Arthur, J.; Winick, H.

    1993-02-01

    This report contains paper on the following topics: A 2 to 4nm High Power FEL On the SLAC Linac; Atomic Physics with an X-ray Laser; High Resolution, Three Dimensional Soft X-ray Imaging; The Role of X-ray Induced Damage in Biological Micro-imaging; Prospects for X-ray Microscopy in Biology; Femtosecond Optical Pulses?; Research in Chemical Physics Surface Science, and Materials Science, with a Linear Accelerator Coherent Light Source; Application of 10 GeV Electron Driven X-ray Laser in Gamma-ray Laser Research; Non-Linear Optics, Fluorescence, Spectromicroscopy, Stimulated Desorption: We Need LCLS' Brightness and Time Scale; Application of High Intensity X-rays to Materials Synthesis and Processing; LCLS Optics: Selected Technological Issues and Scientific Opportunities; Possible Applications of an FEL for Materials Studies in the 60 eV to 200 eV Spectral Region

  6. Electrical discharge light sources: a challenge for the future

    International Nuclear Information System (INIS)

    Zissis, G.

    2001-01-01

    The first electric powder lamp operated that 150 years ago, since then the evolution of light sources is astonishing. Today, more than 10 % of the global electric power produced worldwide serve fore light production from several billions lamps. Since last three decades incandescent lamps are gradually replaced by more energy efficient discharge lamps. In parallel, new generation of light emitting diodes, producing bright colours (including white) with luminous efficacy challenging even discharge lamps, appeared in past years. The objective of this paper is to focus on the state of art in the domain of light sources and discuss the challenges for the near future. (author)

  7. Synchronization System for Next Generation Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Zavriyev, Anton [MagiQ Technologies, Inc., Somerville, MA (United States)

    2014-03-27

    An alternative synchronization technique – one that would allow explicit control of the pulse train including its repetition rate and delay is clearly desired. We propose such a scheme. Our method is based on optical interferometry and permits synchronization of the pulse trains generated by two independent mode-locked lasers. As the next generation x-ray sources will be driven by a clock signal derived from a mode-locked optical source, our technique will provide a way to synchronize x-ray probe with the optical pump pulses.

  8. Permanent magnet based dipole magnets for next generation light sources

    Directory of Open Access Journals (Sweden)

    Takahiro Watanabe

    2017-07-01

    Full Text Available We have developed permanent magnet based dipole magnets for the next generation light sources. Permanent magnets are advantageous over electromagnets in that they consume less power, are physically more compact, and there is a less risk of power supply failure. However, experience with electromagnets and permanent magnets in the field of accelerators shows that there are still challenges to replacing main magnets of accelerators for light sources with permanent magnets. These include the adjustability of the magnetic field, the temperature dependence of permanent magnets, and the issue of demagnetization. In this paper, we present a design for magnets for future light sources, supported by experimental and numerical results.

  9. Laser driven white light source for BRDF measurement

    DEFF Research Database (Denmark)

    Amdemeskel, Mekbib Wubishet; Thorseth, Anders; Dam-Hansen, Carsten

    2017-01-01

    source (UV-VIS-NIR), spectroradiometer and sample holder stepper motor in a dark UV-protected environment. Here, we introduced a special kind of light source which has a bright, stable, broad spectral range and well collimated light output to give a very good angular resolution. The experimental results...... show how stable and reliable is our light source in terms of spectral power distribution, and in BRDF measurement. Furthermore we have shown that we are able to get a well collimated beam and higher power output using set of off-axis parabolic mirrors...

  10. New light Sources for Biomedical Applications

    DEFF Research Database (Denmark)

    Argyraki, Aikaterini

    .005 μg/cm2 of not exposed samples, and 4 fold increase of vitamin D in egg yolk was demonstrated by direct illumination. Applying VIS LED illuminants with specific spectral power distribution in elderly houses resulted in better sleep for elderly women (p=0.007). Light interventions enabled elite...... athletes to conserve their sleep quantity and quality, despite their shifted circadian rhythm. Easier vein identification-access was achieved by applying a special LED illuminant and a statistic evaluation of the human eye ability to identify veins was performed. Finally, lower risks for C-section (OR= 0...

  11. Terminating Surface Electromigration at the Source

    Science.gov (United States)

    Bevan, Kirk H.; Zhu, Wenguang; Guo, Hong; Zhang, Zhenyu

    2011-04-01

    Based on an extensive search across the periodic table utilizing first-principles density functional theory, we discover phosphorus to be an optimal surface electromigration inhibitor on the technologically important Cu(111) surface—the dominant diffusion pathway in modern nanoelectronics interconnects. Unrecognized thus far, such an inhibitor is characterized by energetically favoring (and binding strongly at) the kink sites of step edges. These properties are determined to generally reside in elements that form strong covalent bonds with substrate metal atoms. This finding sheds new light on the possibility of halting surface electromigration via kink blocking impurities.

  12. Science and Technology of Future Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Dierker,S.; Bergmann, U.; Corlett, J.; Dierker, S.; Falcone, R.; Galayda, J.; Gibson, M.; Hastings, J.; Hettel, B.; Hill, J.; Hussain, Z.; Kao, C.-C.; Kirx, J.; Long, G.; McCurdy, B.; Raubenheimer, T.; Sannibale, F.; Seeman, J.; Shen, Z.-X.; Shenoy, g.; Schoenlein, B.; Shen, Q.; Stephenson, B.; Stohr, J.; Zholents, A.

    2008-12-01

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects. The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee [1]. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of

  13. Science and Technology of Future Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, Uwe; Corlett, John; Dierker, Steve; Falcone, Roger; Galayda, John; Gibson, Murray; Hastings, Jerry; Hettel, Bob; Hill, John; Hussain, Zahid; Kao, Chi-Chang; Kirz, Janos; Long, Danielle; McCurdy, Bill; Raubenheimer, Tor; Sannibale, Fernando; Seeman, John; Shen, Z. -X.; Schenoy, Gopal; Schoenlein, Bob; Shen, Qun; Stephenson, Brian; Stohr, Joachim; Zholents, Alexander

    2009-01-28

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter together is of

  14. Diffusion filter eliminates fringe effects of coherent laser light source

    Science.gov (United States)

    Olsasky, M. J.

    1970-01-01

    Diffusion filter comprised of small particles in colloidal suspension reduces the coherence of a laser beam used as a photographic light source. Interference patterns which obscure details in photographic film are eliminated, the intensity and collimation are moderately affected.

  15. Design of Special Light Source for Biological Application

    Directory of Open Access Journals (Sweden)

    Miroslav Steinbauer

    2006-01-01

    Full Text Available This paper presents information about design of special light sources, which is intended for photosynthesis process research, especially for photoinhibition effect. Required properties were continuous spectral characteristic with respect to photosynthetically active wavelength area, possibility of luminous flux regulation and practically zero thermal effect to illuminated object. Owing to new high-performance LED this type of light source was selected. Design of light source consisting of high efficient white LED’s, as well as experimental results, are presented. The special light source was designed and constructed for the research activity on the lichen structure in the Antarctica. This research is made by the Institute of Experimental Biology, Masaryk University, Faculty of Science.

  16. Different light sources in photodynamic therapy for use in photorejuvenation

    CSIR Research Space (South Africa)

    Van Kets, V

    2010-09-01

    Full Text Available Photodynamic therapy (PDT) has recently emerged as a treatment modality for photorejuvenation of the skin. This study is a preliminary investigation into the effect of different light sources to activate hypericin, a plant-derived photosensitizer...

  17. Organic light emitting diode with surface modification layer

    Science.gov (United States)

    Basil, John D.; Bhandari, Abhinav; Buhay, Harry; Arbab, Mehran; Marietti, Gary J.

    2017-09-12

    An organic light emitting diode (10) includes a substrate (12) having a first surface (14) and a second surface (16), a first electrode (32), and a second electrode (38). An emissive layer (36) is located between the first electrode (32) and the second electrode (38). The organic light emitting diode (10) further includes a surface modification layer (18). The surface modification layer (18) includes a non-planar surface (30, 52).

  18. Metallic surfaces decontamination by using laser light

    International Nuclear Information System (INIS)

    Moggia, Fabrice; Lecardonnel, Xavier

    2013-01-01

    Metal surface cleaning appears to be one of the major priorities for industries especially for nuclear industries. The research and the development of a new technology that is able to meet the actual requirements (i.e. waste volume minimization, liquid effluents and chemicals free process...) seems to be the main commitment. Currently, a wide panel of technologies already exists (e.g. blasting, disk sander, electro-decontamination...) but for some of them, the efficiency is limited (e.g, Dry Ice blasting) and for others, the wastes production (liquid and/or solid) remains an important issue. One answer could be the use of a LASER light process. Since a couple of years, the Clean- Up Business Unit of the AREVA group investigates this decontamination technology. Many tests have been already performed in inactive (i.e. on simulants such as paints, inks, resins, metallic oxides) or active conditions (i.e. pieces covered with a thick metallic oxide layer and metallic pieces covered with grease). The paper will describe the results obtained in term of decontamination efficiency during all our validation process. Metallographic characterizations (i.e. SEM, X-ray scattering) and radiological analysis will be provided. We will also focus our paper on the future deployment of the LASER technology and its commercial use at La Hague reprocessing facility in 2013. (authors)

  19. Backscattering of light ions from metal surfaces

    International Nuclear Information System (INIS)

    Verbeek, H.

    1975-07-01

    When a metal target is bombarded with light ions some are implanted and some are reflected from the surface or backscattered from deeper layers. This results in an energy distribution of the backscattered particles which reaches from zero to almost the primary energy. The number of the backscattered particles and their energy, angular, and charge distributions depends largely on the energy and the ion target combination. For high energies (i.e., greater than50 keV for protons) particles are backscattered in a single collision governed by the Rutherford cross section. Protons and He-ions with energies of 100 keV to several MeV are widely used for thin film analysis. For lower energies multiple collisions and the screening of the Coulomb potential have to be taken into account, which makes the theoretical treatment more difficult. This energy region is, however, of special interest in the field of nuclear fusion research. Some recent results for energies below 20 keV are discussed in some detail. (auth)

  20. Modification of light sources for appropriate biological action

    Energy Technology Data Exchange (ETDEWEB)

    Kozakov, R; Schoepp, H; Franke, St [Leibniz Institute of Plasma Science and Technology, Felix-Hausdorff-Str. 2, D-17489 Greifswald (Germany); Stoll, C; Kunz, D, E-mail: kozakov@inp-greifswald.d [Charite-Universitymedicine Berlin, Sleep Research and Clinical Chronobiology, Gr. Hamburger Str. 5-11, D-10115 Berlin (Germany)

    2010-06-16

    The impact of the non-visual action of light on the design of novel light sources is discussed. Therefore possible modifications of lamps dealing with spectral tailoring and their action on melatonin suppression in usual life situations are investigated. The results of melatonin suppression by plasma lamps are presented. It is shown that even short-time exposure to usual light levels in working areas has an influence on the melatonin onset.

  1. Development and evaluation of a light-emitting diode endoscopic light source

    Science.gov (United States)

    Clancy, Neil T.; Li, Rui; Rogers, Kevin; Driscoll, Paul; Excel, Peter; Yandle, Ron; Hanna, George; Copner, Nigel; Elson, Daniel S.

    2012-03-01

    Light-emitting diode (LED) based endoscopic illumination devices have been shown to have several benefits over arclamp systems. LEDs are energy-efficient, small, durable, and inexpensive, however their use in endoscopy has been limited by the difficulty in efficiently coupling enough light into the endoscopic light cable. We have demonstrated a highly homogenised lightpipe LED light source that combines the light from four Luminus LEDs emitting in the red, green, blue and violet using innovative dichroics that maximise light throughput. The light source spectrally combines light from highly divergent incoherent sources that have a Lambertian intensity profile to provide illumination matched to the acceptance numerical aperture of a liquid light guide or fibre bundle. The LED light source was coupled to a standard laparoscope and performance parameters (power, luminance, colour temperature) compared to a xenon lamp. Although the total illuminance from the endoscope was lower, adjustment of the LEDs' relative intensities enabled contrast enhancement in biological tissue imaging. The LED light engine was also evaluated in a minimally invasive surgery (MIS) box trainer and in vivo during a porcine MIS procedure where it was used to generate 'narrowband' images. Future work using the violet LED could enable photodynamic diagnosis of bladder cancer.

  2. A new LED light source for display cases

    DEFF Research Database (Denmark)

    Dam-Hansen, Carsten; Petersen, Paul Michael

    Abstract: We report a new LED light source suitable for illumination of gold objects. It has a variable correlated color temperature from 2760 K to 2200 K with a high color rendering index up to 97.......Abstract: We report a new LED light source suitable for illumination of gold objects. It has a variable correlated color temperature from 2760 K to 2200 K with a high color rendering index up to 97....

  3. Survey, alignment, and beam stability at the Advanced Light Source

    International Nuclear Information System (INIS)

    Krebs, G.F.

    1997-10-01

    This paper describes survey and alignment at the Lawrence Berkeley Laboratories Advanced Light Source (ALS) accelerators from 1993 to 1997. The ALS is a third generation light source requiring magnet alignment to within 150 microns. To accomplish this, a network of monuments was established and maintained. Monthly elevation surveys show the movement of the floor over time. Inclinometers have recently been employed to give real time information about magnet, vacuum tank and magnet girder motion in the ALS storage ring

  4. Performance of single mechanoluminescent particle as ubiquitous light source.

    Science.gov (United States)

    Terasaki, Nao; Xu, Chao-Nan

    2014-08-01

    In this study, we have investigated mechanoluminescent (ML) performance of single ML particle as ubiquitous light source. When using high-speed CCD camera with image intensifier and microscopic equipment, mechanoluminescence from single particle was observed. As to the quantitative ML evaluation of the single ML particle was carried out using photomultiplier, and successfully estimated the performance of the single ML particle as an intensity controllable light source in nW order. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Advanced light source, User`s Handbook, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The Advanced Light Source (ALS) is a national facility for scientific research and development located at the Lawrence Berkeley National Laboratory (LBNL) of the University of California. Its purpose is to generate beams of very bright light in the ultraviolet and soft x-ray regions of the spectrum. The facility is open to researchers from industry, universities, and government laboratories.

  6. New lasers and light sources - old and new risks?

    DEFF Research Database (Denmark)

    Paasch, Uwe; Schwandt, Antje; Seeber, Nikolaus

    2017-01-01

    Recent developments (new wavelengths, treatment concepts, and combinations) in the field of lasers, intense pulsed light (IPL), LED, as well as new energy and light sources have opened up new therapeutic options that extend beyond mere aesthetic indications. Thus, while fractional lasers used to ...

  7. Hyperspectral microscopy to identify foodborne bacteria with optimum lighting source

    Science.gov (United States)

    Hyperspectral microscopy is an emerging technology for rapid detection of foodborne pathogenic bacteria. Since scattering spectral signatures from hyperspectral microscopic images (HMI) vary with lighting sources, it is important to select optimal lights. The objective of this study is to compare t...

  8. Solid state light source for wavelength multiplex 3D

    Science.gov (United States)

    Huang, Junejei

    2012-10-01

    A solid state light source provided for wavelength multiplex 3D Display is proposed. The system of solid state light source includes blue laser arrays of two wavelengths, a 2-ring phosphor wheel, a multi-band filter and a TIR prism. Green and red phosphors excited by blue lasers provide the original green and red lights of wide bandwidth. By passing through or reflected by a multi-band filter, two groups of green and red lights of narrow bandwidth for left or right eyes are selected. Blue lasers of two wavelengths also provide two blue lights for left and right eyes. Instead of using a second rotated narrow band filters that synchronized with the first phosphor wheel, a wheel having two rings coated with mirrors and phosphors is used to replace the synchronization existing in the conventional two wheels method. After passing the 2-ring wheel, the light source switches between two light paths that lead to be reflected or transmitting through the multiband filter. The multi-band filter can be disposed in a telecentric optical path to secure a high efficiency for the filter. A compact spectral multiplex light source is realized and can be directly attached to any existing optical engine.

  9. Directional Dicke Subradiance with Nonclassical and Classical Light Sources

    Science.gov (United States)

    Bhatti, Daniel; Schneider, Raimund; Oppel, Steffen; von Zanthier, Joachim

    2018-03-01

    We investigate Dicke subradiance of N ≥2 distant quantum sources in free space, i.e., the spatial emission patterns of spontaneously radiating noninteracting multilevel atoms or multiphoton sources, prepared in totally antisymmetric states. We find that the radiated intensity is marked by a full suppression of spontaneous emission in particular directions. In resemblance to the analogous, yet inverted, superradiant emission profiles of N distant two-level atoms prepared in symmetric Dicke states, we call the corresponding emission patterns directional Dicke subradiance. We further derive that higher-order intensity correlations of the light emitted by statistically independent thermal light sources display the same directional Dicke subradiant behavior and show that it stems from the same interference phenomenon as in the case of quantum sources. We finally present measurements of directional Dicke subradiance for N =2 ,…,5 distant thermal light sources corroborating the theoretical findings.

  10. Magneto-optical light scattering from ferromagnetic surfaces

    International Nuclear Information System (INIS)

    Gonzalez, M.U.; Armelles, G.; Martinez Boubeta, C.; Cebollada, A.

    2003-01-01

    We have studied the optical and magneto-optical components of the light scattered by the surface of several Fe films with different morphologies. We present a method, based on the ratio between the optical and magneto-optical components of the scattered intensity, to discern the physical origin, either structural or magnetic corrugation, of the light scattered by these ferromagnetic surfaces. Surface versus bulk magnetic information can be separated by magneto-optical light scattering measurements, the scattered light being more sensitive to magnetization differences between surface and bulk than the reflected one

  11. A Test Beamline on Diamond Light Source

    International Nuclear Information System (INIS)

    Sawhney, K. J. S.; Dolbnya, I. P.; Tiwari, M. K.; Alianelli, L.; Scott, S. M.; Preece, G. M.; Pedersen, U. K.; Walton, R. D.

    2010-01-01

    A Test beamline B16 has been built on the 3 GeV Diamond synchrotron radiation source. The beamline covers a wide photon energy range from 2 to 25 keV. The beamline is highly flexible and versatile in terms of the available beam size (a micron to 100 mm) and the range of energy resolution and photon flux; by virtue of its several operational modes, and the different inter-changeable instruments available in the experiments hutch. Diverse experimental configurations can be flexibly configured using a five-circle diffractometer, a versatile optics test bench, and a suite of detectors. Several experimental techniques including reflectivity, diffraction and imaging are routinely available. Details of the beamline and its measured performance are presented.

  12. Direction-division multiplexed holographic free-electron-driven light sources

    Science.gov (United States)

    Clarke, Brendan P.; MacDonald, Kevin F.; Zheludev, Nikolay I.

    2018-01-01

    We report on a free-electron-driven light source with a controllable direction of emission. The source comprises a microscopic array of plasmonic surface-relief holographic domains, each tailored to direct electron-induced light emission at a selected wavelength into a collimated beam in a prescribed direction. The direction-division multiplexed source is tested by driving it with the 30 kV electron beam of a scanning electron microscope: light emission, at a wavelength of 800 nm in the present case, is switched among different output angles by micron-scale repositioning of the electron injection point among domains. Such sources, with directional switching/tuning possible at picosecond timescales, may be applied to field-emission and surface-conduction electron-emission display technologies, optical multiplexing, and charged-particle-beam position metrology.

  13. Inherent visible light signature of an intense underwater ultraviolet light source due to combined Raman and fluorescence effects

    Science.gov (United States)

    Mazel, Charles H.; Kalata-Olson, Jody; Pham, Chuong N.

    2000-07-01

    We investigated the utility of a portable, intense source of ultraviolet light for diver use in support of Very Shallow Water operations. The working hypothesis was that the light would be of use to divers at short-to-medium ranges (up to several meters) while remaining invisible to surface observers due to the incoherent insensitivity of the human eye to ultraviolet light. The light source contained an arc discharge lamp rich in short wavelengths and was fitted with a filter that transmitted only the near ultraviolet portion of the spectrum. In-water tests were made in darkness using Navy divers both in a natural coastal environment and in a test tank. It was found that the light was of limited utility to the divers. In addition, the light was not covert because of a bluish-white glow associated with the ultraviolet beam. Subsequent measurements demonstrated that the visible glow was produced by a combination of fluorescence of dissolved organic matter in the water and Raman scatter from the water itself. The relative importance of the two factors varied with water type. These two effects that transform light from the invisible to the visible impose inherent limitations on the use of ultraviolet light for covert operations.

  14. Visual color matching system based on RGB LED light source

    Science.gov (United States)

    Sun, Lei; Huang, Qingmei; Feng, Chen; Li, Wei; Wang, Chaofeng

    2018-01-01

    In order to study the property and performance of LED as RGB primary color light sources on color mixture in visual psychophysical experiments, and to find out the difference between LED light source and traditional light source, a visual color matching experiment system based on LED light sources as RGB primary colors has been built. By simulating traditional experiment of metameric color matching in CIE 1931 RGB color system, it can be used for visual color matching experiments to obtain a set of the spectral tristimulus values which we often call color-matching functions (CMFs). This system consists of three parts: a monochromatic light part using blazed grating, a light mixing part where the summation of 3 LED illuminations are to be visually matched with a monochromatic illumination, and a visual observation part. The three narrow band LEDs used have dominant wavelengths of 640 nm (red), 522 nm (green) and 458 nm (blue) respectively and their intensities can be controlled independently. After the calibration of wavelength and luminance of LED sources with a spectrophotometer, a series of visual color matching experiments have been carried out by 5 observers. The results are compared with those from CIE 1931 RGB color system, and have been used to compute an average locus for the spectral colors in the color triangle, with white at the center. It has been shown that the use of LED is feasible and has the advantages of easy control, good stability and low cost.

  15. Visible and ultraviolet light sources based nonlinear interaction of lasers

    DEFF Research Database (Denmark)

    Andersen, Martin Thalbitzer; Tidemand-Lichtenberg, Peter; Jain, Mayank

    Different light sources can be used for optically stimulated luminescence measurements and usually a halogen lamp in combination with filters or light emitting diodes (LED’s) are used to provide the desired stimulation wavelength. However lasers can provide a much more well-defined beam, very nar...... for synthesizing any wavelength in the visible and ultraviolet light based sum frequency generation between two lasers is presented.......Different light sources can be used for optically stimulated luminescence measurements and usually a halogen lamp in combination with filters or light emitting diodes (LED’s) are used to provide the desired stimulation wavelength. However lasers can provide a much more well-defined beam, very...

  16. National synchrotron light source basic design and project status

    International Nuclear Information System (INIS)

    van Steenbergen, A.

    1981-01-01

    A summary description and the basic design parameters of the National Synchrotron Light Source, a facility for the generation of intense synchrotron radiation in the vuv and x-ray range is presented, the parameters of the sources are given, the presently planned facility beam lines are tabulated and the status of the project is indicated

  17. A Stroboscopic Light Source for Experiments in Mechanics

    Science.gov (United States)

    Mayer, V. V.; Varaksina, E. I.

    2017-01-01

    We propose to attach a small stroboscopic light source to a moving object and connect the source to a pulse generator with the help of insulated thin flexible multi-cored wires. Students can assemble such a device independently in a school laboratory. The device can be used to obtain trajectories with time marks in students' research projects in…

  18. Diamond Light Source - A Next Generation SR Facility

    International Nuclear Information System (INIS)

    Materlik, G.

    2004-01-01

    After the very successful start and the by now almost 10 years operation of the 3rd generation x-ray sources ESRF, APS and Spring-8 smaller storage rings are being planned and constructed with properties emphasising applications with photon energies around the 10 keV spectral region. In the UK the Government and the medical foundation Wellcome Trust have decided to build the Diamond Light Source Facility in the South of Oxfordshire right next to the Rutherford Appleton Laboratory. The joint venture company Diamond Light Source Limited has been created to plan, construct, and operate this facility. (author)

  19. Optical laser systems at the Linac Coherent Light Source

    International Nuclear Information System (INIS)

    Minitti, Michael P.; Robinson, Joseph S.; Coffee, Ryan N.; Edstrom, Steve; Gilevich, Sasha; Glownia, James M.; Granados, Eduardo; Hering, Philippe; Hoffmann, Matthias C.; Miahnahri, Alan; Milathianaki, Despina; Polzin, Wayne; Ratner, Daniel; Tavella, Franz; Vetter, Sharon; Welch, Marc; White, William E.; Fry, Alan R.

    2015-01-01

    This manuscript serves as a reference to describe the optical laser sources and capabilities at the Linac Coherent Light Source. Ultrafast optical lasers play an essential role in exploiting the unique capabilities of recently commissioned X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS). Pump–probe experimental techniques reveal ultrafast dynamics in atomic and molecular processes and reveal new insights in chemistry, biology, material science and high-energy-density physics. This manuscript describes the laser systems and experimental methods that enable cutting-edge optical laser/X-ray pump–probe experiments to be performed at LCLS

  20. Optical laser systems at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Minitti, Michael P.; Robinson, Joseph S.; Coffee, Ryan N.; Edstrom, Steve; Gilevich, Sasha; Glownia, James M.; Granados, Eduardo; Hering, Philippe; Hoffmann, Matthias C.; Miahnahri, Alan; Milathianaki, Despina; Polzin, Wayne; Ratner, Daniel; Tavella, Franz; Vetter, Sharon; Welch, Marc; White, William E.; Fry, Alan R., E-mail: alanfry@slac.stanford.edu [Linac Coherent Light Source, SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, CA 94025 (United States)

    2015-04-22

    This manuscript serves as a reference to describe the optical laser sources and capabilities at the Linac Coherent Light Source. Ultrafast optical lasers play an essential role in exploiting the unique capabilities of recently commissioned X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS). Pump–probe experimental techniques reveal ultrafast dynamics in atomic and molecular processes and reveal new insights in chemistry, biology, material science and high-energy-density physics. This manuscript describes the laser systems and experimental methods that enable cutting-edge optical laser/X-ray pump–probe experiments to be performed at LCLS.

  1. Internal heat gain from different light sources in the building lighting systems

    Science.gov (United States)

    Suszanowicz, Dariusz

    2017-10-01

    EU directives and the Construction Law have for some time required investors to report the energy consumption of buildings, and this has indeed caused low energy consumption buildings to proliferate. Of particular interest, internal heat gains from installed lighting affect the final energy consumption for heating of both public and residential buildings. This article presents the results of analyses of the electricity consumption and the luminous flux and the heat flux emitted by different types of light sources used in buildings. Incandescent light, halogen, compact fluorescent bulbs, and LED bulbs from various manufacturers were individually placed in a closed and isolated chamber, and the parameters for their functioning under identical conditions were recorded. The heat flux emitted by 1 W nominal power of each light source was determined. Based on the study results, the empirical coefficients of heat emission and energy efficiency ratios for different types of lighting sources (dependent lamp power and the light output) were designated. In the heat balance of the building, the designated rates allow for precise determination of the internal heat gains coming from lighting systems using various light sources and also enable optimization of lighting systems of buildings that are used in different ways.

  2. Surface tension mediated conversion of light to work

    Science.gov (United States)

    Okawa, David; Pastine, Stefan J; Zettl, Alexander K; Frechet, Jean M. J

    2014-12-02

    Disclosed are a method and apparatus for converting light energy to mechanical energy by modification of surface tension on a supporting fluid. The apparatus comprises an object which may be formed as a composite object comprising a support matrix and a highly light absorptive material. The support matrix may comprise a silicon polymer. The highly light absorptive material may comprise vertically aligned carbon nanotubes (VANTs) embedded in the support matrix. The composite object is supported on a fluid. By exposing the highly light absorptive material to light, heat is generated, which changes the surface tension of the composite object, causing it to move physically within the fluid.

  3. Phototaxis of Grapholitha molesta (Lepidoptera: Olethreutidae) to Different Light Sources.

    Science.gov (United States)

    Sun, Y-X; Tian, A; Zhang, X-B; Zhao, Z-G; Zhang, Z-W; Ma, R-Y

    2014-10-01

    The Oriental Fruit Moth Grapholita molesta (Busck) causes substantial damage to stone and pome fruit crops worldwide. Light-based traps offer a potential means for pest monitoring and management. In this study, we tested the preference of G. molesta for the following light sources: monochromatic light produced from light-emitting diodes (LEDs) (red, orange, yellow, green, blue, violet, and white), specific wavelengths of light produced from filters (405, 450, 480, 512, 540, 576, and 610 nm), and polychromatic light produced by different numbers (0, 12, 24, and 36) of green, blue, and violet LEDs. The arrangement of polychromatic lights was based on an orthogonal design matrix of L16 (4(3)). Based on the results of former studies, we further determined the optimal number of green and violet LEDs. The results showed that: 1) G. molesta strongly preferred the green, violet, and blue LEDs; 2) G. molesta significantly preferred light at 405 nm, followed by 540 nm, and showed no phototaxis to 480 nm; 3) for the polychromatic light configuration, violet and green were the factors that determined the preference of G. molesta, and the lamp with 12 violet LEDs captured the most moths; and 4) for the lamps with different light intensities, 36 violet LEDs or 12 green LEDs attracted the most moths, with the former performing better. © 2014 Entomological Society of America.

  4. Suboptimal light conditions influence source-sink metabolism during flowering

    Directory of Open Access Journals (Sweden)

    Annelies eChristiaens

    2016-03-01

    Full Text Available Reliance on carbohydrates during flower forcing was investigated in one early and one late flowering cultivar of azalea (Rhododendron simsii hybrids. Carbohydrate accumulation, invertase activity, and expression of a purported sucrose synthase gene (RsSUS was monitored during flower forcing under suboptimal (natural and optimal (supplemental light light conditions, after a cold treatment (7°C + dark to break flower bud dormancy. Post-production sucrose metabolism and flowering quality was also assessed. Glucose and fructose concentrations and invertase activity increased in petals during flowering, while sucrose decreased. In suboptimal light conditions RsSUS expression in leaves increased as compared to optimal light conditions, indicating that plants in suboptimal light conditions have a strong demand for carbohydrates. However, carbohydrates in leaves were markedly lower in suboptimal light conditions compared to optimal light conditions. This resulted in poor flowering of plants in suboptimal light conditions. Post-production flowering relied on the stored leaf carbon, which could be accumulated under optimal light conditions in the greenhouse. These results show that flower opening in azalea relies on carbohydrates imported from leaves and is source-limiting under suboptimal light conditions.

  5. Use of gaseous tritium light sources (Beta lights) with respect to nocturnal illumination

    International Nuclear Information System (INIS)

    Solomon, D.E.

    1988-01-01

    A number/letter plate for use in, for example darkened buildings has spaced apart gaseous tritium light sources (beta lights) arranged centrally along the indicia on a reflective background sealed in clear translucent plastics. Uses include house numbers, name plates, telephone numbers, notices, product advertisements, vehicle registration plates and names or trade marks on products. (author)

  6. Increased collection efficiency of LIFI high intensity electrodeless light source

    Science.gov (United States)

    Hafidi, Abdeslam; DeVincentis, Marc; Duelli, Markus; Gilliard, Richard

    2008-02-01

    Recently, RF driven electrodeless high intensity light sources have been implemented successfully in the projection display systems for HDTV and videowall applications. This paper presents advances made in the RF waveguide and electric field concentrator structures with the purpose of reducing effective arc size and increasing light collection. In addition, new optical designs are described that further improve system efficiency. The results of this work demonstrate that projection system light throughput is increased relative to previous implementations and performance is optimized for home theater and other front projector applications that maintain multi-year lifetime without re-lamping, complete spectral range, fast start times and high levels of dynamic contrast due to dimming flexibility in the light source system.

  7. Visible light scatter as quantitative information source on milk constituents

    DEFF Research Database (Denmark)

    Melentieva, Anastasiya; Kucheryavskiy, Sergey; Bogomolov, Andrey

    2012-01-01

    at the data analysis stage. The region of visible (Vis) light (400-800 nm) is economically attractive, because it offers a range of inexpensive light sources, optics and detectors. At present, however, it is commonly considered useless, because of the light scatter by fat globules (1-10 μm) and protein......VISIBLE LIGHT SCATTER AS A QUANTITATIVE INFORMATION SOURCE ON MILK CONSTITUENTS A. Melenteva 1, S. Kucheryavski 2, A. Bogomolov 1,31Samara State Technical University, Molodogvardeyskaya Street 244, 443100 Samara, Russia. 2Aalborg University, campus Esbjerg, Niels Bohrs vej 8, 6700 Esbjerg, Denmark....... 3J&M Analytik AG, Willy-Messerschmitt-Strasse 8, 73457 Essingen, Germany. bogomolov@j-m.de Fat and protein are two major milk nutrients that are routinely analyzed in the dairy industry. Growing food quality requirements promote the dissemination of spectroscopic analysis, enabling real...

  8. Electrodeless lighting RF power source development. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-30

    An efficient, solid state RF power source has been developed on this NICE project for exciting low power electrodeless lamp bulbs. This project takes full advantage of concurrent advances in electrodeless lamp technology. Electrodeless lamp lighting systems utilizing the sulfur based bulb type developed by Fusion Lighting, Inc., is an emerging technology which is based on generating light in a confined plasma created and sustained by RF excitation. The bulb for such a lamp is filled with a particular element and inert gas at low pressure when cold. RF power from the RF source creates a plasma within the bulb which reaches temperatures approaching those of high pressure discharge lamp plasmas. At these temperatures the plasma radiates substantial visible light with a spectrum similar to sunlight.

  9. Control and Driving Methods for LED Based Intelligent Light Sources

    DEFF Research Database (Denmark)

    Beczkowski, Szymon

    High power light-emitting diodes allow the creation of luminaires capable of generating saturated colour light at very high efficacies. Contrary to traditional light sources like incandescent and high-intensity discharge lamps, where colour is generated using filters, LEDs use additive light mixing......, where the intensity of each primary colour diode has to be adjusted to the needed intensity to generate specified colour. The function of LED driver is to supply the diode with power needed to achieve the desired intensity. Typically, the drivers operate as a current source and the intensity...... of the diode is controlled either by varying the magnitude of the current or by driving the LED with a pulsed current and regulate the width of the pulse. It has been shown previously, that these two methods yield different effects on diode's efficacy and colour point. A hybrid dimming strategy has been...

  10. Feasibility of Ultraviolet Light Emitting Diodes as an Alternative Light Source for Photocatalysis

    Science.gov (United States)

    Levine, Langanf H.; Richards, Jeffrey T.; Soler, Robert; Maxik, Fred; Coutts, Janelle; Wheeler, Raymond M.

    2011-01-01

    The objective of this study was to determine whether ultraviolet light emitting diodes (UV-LEDs) could serve as an alternative photon source efficiently for heterogeneous photocatalytic oxidation (PCO). An LED module consisting of 12 high-power UV-A LEDs was designed to be interchangeable with a UV-A fluorescent black light blue (BLB) lamp in a Silica-Titania Composite (STC) packed bed annular reactor. Lighting and thermal properties were characterized to assess the uniformity and total irradiant output. A forward current of (I(sub F)) 100 mA delivered an average irradiance of 4.0 m W cm(exp -2), which is equivalent to the maximum output of the BLB, but the irradiance of the LED module was less uniform than that of the BLB. The LED- and BLB-reactors were tested for the oxidization of 50 ppmv ethanol in a continuous flow-through mode with 0.94 sec space time. At the same irradiance, the UV-A LED reactor resulted in a lower PCO rate constant than the UV-A BLB reactor (19.8 vs. 28.6 nM CO2 sec-I), and consequently lower ethanol removal (80% vs. 91%) and mineralization efficiency (28% vs. 44%). Ethanol mineralization increased in direct proportion to the irradiance at the catalyst surface. This result suggests that reduced ethanol mineralization in the LED- reactor could be traced to uneven irradiance over the photocatalyst, leaving a portion of the catalyst was under-irradiated. The potential of UV-A LEDs may be fully realized by optimizing the light distribution over the catalyst and utilizing their instantaneous "on" and "off' feature for periodic irradiation. Nevertheless, the current UV-A LED module had the same wall plug efficiency (WPE) of 13% as that of the UV-A BLB. These results demonstrated that UV-A LEDs are a viable photon source both in terms of WPE and PCO efficiency.

  11. Does the light source affect the repairability of composite resins?

    Science.gov (United States)

    Karaman, Emel; Gönülol, Nihan

    2014-01-01

    The aim of this study was to examine the effect of the light source on the microshear bond strength of different composite resins repaired with the same substrate. Thirty cylindrical specimens of each composite resin--Filtek Silorane, Filtek Z550 (3M ESPE), Gradia Direct Anterior (GC), and Aelite Posterior (BISCO)--were prepared and light-cured with a QTH light curing unit (LCU). The specimens were aged by thermal cycling and divided into three subgroups according to the light source used--QTH, LED, or PAC (n = 10). They were repaired with the same substrate and a Clearfil Repair Kit (Kuraray). The specimens were light-cured and aged for 1 week in distilled water at 37 °C. The microshear bond strength and failure modes were assessed. There was no significant difference in the microshear bond strength values among the composite resins, except for the Filtek Silorane group that showed significantly lower bond strength values when polymerized with the PAC unit compared to the QTH or LED unit. In conclusion, previously placed dimethacrylate-based composites can be repaired with different light sources; however, if the composite to be repaired is silorane-based, then using a QTH or LED device may be the best option.

  12. Does the light source affect the repairability of composite resins?

    Directory of Open Access Journals (Sweden)

    Emel KARAMAN

    2014-08-01

    Full Text Available The aim of this study was to examine the effect of the light source on the microshear bond strength of different composite resins repaired with the same substrate. Thirty cylindrical specimens of each composite resin—Filtek Silorane, Filtek Z550 (3M ESPE, Gradia Direct Anterior (GC, and Aelite Posterior (BISCO—were prepared and light-cured with a QTH light curing unit (LCU. The specimens were aged by thermal cycling and divided into three subgroups according to the light source used—QTH, LED, or PAC (n = 10. They were repaired with the same substrate and a Clearfil Repair Kit (Kuraray. The specimens were light-cured and aged for 1 week in distilled water at 37 °C. The microshear bond strength and failure modes were assessed. There was no significant difference in the microshear bond strength values among the composite resins, except for the Filtek Silorane group that showed significantly lower bond strength values when polymerized with the PAC unit compared to the QTH or LED unit. In conclusion, previously placed dimethacrylate-based composites can be repaired with different light sources; however, if the composite to be repaired is silorane-based, then using a QTH or LED device may be the best option.

  13. Validation of alternate light sources for detection of bruises in non-embalmed and embalmed cadavers.

    Science.gov (United States)

    Olds, Kelly; Byard, Roger W; Winskog, Calle; Langlois, Neil E I

    2017-03-01

    Bruising is frequently documented in cases of violence for use as forensic evidence. However, bruises can be overlooked if they are not visible to the naked eye. Alternate light sources such as ultraviolet, narrow band, and infrared have been used in an attempt to reveal the presence of bruising that is not otherwise apparent. However, there is a significant gap in knowledge surrounding this technique as it has not been validated against histology to confirm that bruising is genuinely being enhanced. A recent study evaluated the ability of alternate light sources to enhance visibility of bruises using a pigskin model. However, histological confirmation of bruising in humans using these light sources has not yet been performed. In this study, embalmed and non-embalmed human cadavers were used. Bodies were surveyed with alternate light sources, and enhanced regions that were unapparent under white light were photographed with the alternate light sources and sampled for histological assessment. Immunohistochemical staining for the red blood cell surface protein glycophorin was used determine if the enhanced area was a bruise (defined by the presence of extravasated erythrocytes). Photographs of areas confirmed to be bruises were analyzed using the program Fiji to measure enhancement, which was defined as an increase in the measured transverse diameter. In the non-embalmed and the embalmed cadavers violet alternate light produced the greatest enhancement of histologically confirmed bruises, followed by blue (both p < 0.0001). Regions that were not confirmed as bruises also enhanced, indicating that light sources may not be specific. This suggests that the use of light sources to enhance the visibility of bruising should be undertaken with caution and further studies are required.

  14. Dynamic Aperture Measurements at the Advanced Light Source

    International Nuclear Information System (INIS)

    Decking, W.; Robin, D.

    1999-01-01

    A large dynamic aperture for a storage ring is of importance for long lifetimes and a high injection efficiency. Measurements of the dynamic aperture of the third generation synchrotron light source Advanced Light Source (ALS) using beam excitation with kicker magnets are presented. The experiments were done for various accelerator conditions, allowing us to investigate the influence of different working points, chromaticities, insertion devices, etc.. The results are compared both with tracking calculations and a simple model for the dynamic aperture yielding good agreements. This gives us confidence in the predictability of the nonlinear accelerator model. This is especially important for future ALS upgrades as well as new storage ring designs

  15. Laser wakefield accelerator based light sources: potential applications and requirements

    Energy Technology Data Exchange (ETDEWEB)

    Albert, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). NIF and Photon Sciences; Thomas, A. G. [Univ. of Michigan, Ann Arbor, MI (United States). Dept. of Nuclear Engineering and Radiological Sciences; Mangles, S. P.D. [Imperial College, London (United Kingdom). Blackett Lab.; Banerjee, S. [Univ. of Nebraska, Lincoln, NE (United States); Corde, S. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Flacco, A. [ENSTA, CNRS, Ecole Polytechnique, Palaiseau (France); Litos, M. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Neely, D. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL). Central Laser Facility; Viera, J. [Univ. of Lisbon (Portugal). GoLP-Inst. de Plasmas e Fusao Nuclear-Lab. Associado; Najmudin, Z. [Imperial College, London (United Kingdom). Blackett Lab.; Bingham, R. [Science and Technology Facilities Council (STFC), Oxford (United Kingdom). Rutherford Appleton Lab. (RAL). Central Laser Facility; Joshi, C. [Univ. of California, Los Angeles, CA (United States). Dept. of Electrical Engineering; Katsouleas, T. [Duke Univ., Durham, NC (United States). Platt School of Engineering

    2015-01-15

    In this article we review the prospects of laser wakefield accelerators as next generation light sources for applications. This work arose as a result of discussions held at the 2013 Laser Plasma Accelerators Workshop. X-ray phase contrast imaging, X-ray absorption spectroscopy, and nuclear resonance fluorescence are highlighted as potential applications for laser-plasma based light sources. We discuss ongoing and future efforts to improve the properties of radiation from plasma betatron emission and Compton scattering using laser wakefield accelerators for these specific applications.

  16. The Advanced Light Source (ALS) Radiation Safety System

    International Nuclear Information System (INIS)

    Ritchie, A.L.; Oldfather, D.E.; Lindner, A.F.

    1993-08-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory (LBL) is a 1.5 Gev synchrotron light source facility consisting of a 120 kev electron gun, 50 Mev linear accelerator, 1.5 Gev booster synchrotron, 200 meter circumference electron storage ring, and many photon beamline transport systems for research. Figure 1. ALS floor plan. Pairs of neutron and gamma radiation monitors are shown as dots numbered from 1 to 12. The Radiation Safety System for the ALS has been designed and built with a primary goal of providing protection against inadvertent personnel exposure to gamma and neutron radiation and, secondarily, to enhance the electrical safety of select magnet power supplies

  17. The Advanced Light Source (ALS) Radiation Safety System

    International Nuclear Information System (INIS)

    Ritchie, A.; Oldfather, D.; Lindner, A.

    1993-05-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory (LBL) is a 1.5 GeV synchrotron light source facility consisting of a 120 keV electron gun, 50 MeV linear accelerator, 1.5 Gev booster synchrotron, 200 meter circumference electron storage ring, and many photon beamline transport systems for research. The Radiation Safety System for the ALS has been designed and built with a primary goal of providing protection against inadvertent personnel exposure to gamma and neutron radiation and, secondarily, to enhance the electrical safety of select magnet power supplies

  18. Design of TIR collimating lens for ordinary differential equation of extended light source

    Science.gov (United States)

    Zhan, Qianjing; Liu, Xiaoqin; Hou, Zaihong; Wu, Yi

    2017-10-01

    The source of LED has been widely used in our daily life. The intensity angle distribution of single LED is lambert distribution, which does not satisfy the requirement of people. Therefore, we need to distribute light and change the LED's intensity angle distribution. The most commonly method to change its intensity angle distribution is the free surface. Generally, using ordinary differential equations to calculate free surface can only be applied in a point source, but it will lead to a big error for the expand light. This paper proposes a LED collimating lens based on the ordinary differential equation, combined with the LED's light distribution curve, and adopt the method of calculating the center gravity of the extended light to get the normal vector. According to the law of Snell, the ordinary differential equations are constructed. Using the runge-kutta method for solution of ordinary differential equation solution, the curve point coordinates are gotten. Meanwhile, the edge point data of lens are imported into the optical simulation software TracePro. Based on 1mm×1mm single lambert body for light conditions, The degrees of collimating light can be close to +/-3. Furthermore, the energy utilization rate is higher than 85%. In this paper, the point light source is used to calculate partial differential equation method and compared with the simulation of the lens, which improve the effect of 1 degree of collimation.

  19. Brazilian Synchrotron Light Source: current results and future perspectives

    Science.gov (United States)

    Roque da Silva, Antonio Jose

    2013-03-01

    The application of synchrotron radiation in a great variety of fields in general, and condensed matter in particular, has increased steadily worldwide. This, to a large extent, is a result of the availability of the much brighter third-generation light sources, which opened up new experimental techniques. Brazil gave an important contribution to science in Latin America through the development of the necessary technology and the construction of the first synchrotron in the southern hemisphere, still the only one in Latin America. The Laboratório Nacional de Luz Síncrotron - LNLS, operates this installation as an open facility since 1997, having today more than 1300 users yearly. Despite all this success, the current Brazilian light source is a second-generation machine, with relatively low electron energy, high emittance and few straight sections for insertion devices. LNLS is currently engaged in the design and construction of a new, third-generation synchrotron light source. It is being planned to be a state of the art machine, providing tools for cutting edge research that are non existent today in Brazil. In this talk an overview of the status of the current Brazilian light source will be provided, illustrated with some experimental results from users, as well as the future perspectives of the new synchrotron source.

  20. Applications of laser wakefield accelerator-based light sources

    International Nuclear Information System (INIS)

    Albert, Felicie; Thomas, Alec G. R.

    2016-01-01

    Laser-wakefield accelerators (LWFAs) were proposed more than three decades ago, and while they promise to deliver compact, high energy particle accelerators, they will also provide the scientific community with novel light sources. In a LWFA, where an intense laser pulse focused onto a plasma forms an electromagnetic wave in its wake, electrons can be trapped and are now routinely accelerated to GeV energies. From terahertz radiation to gamma-rays, this article reviews light sources from relativistic electrons produced by LWFAs, and discusses their potential applications. Betatron motion, Compton scattering and undulators respectively produce x-rays or gamma-rays by oscillating relativistic electrons in the wakefield behind the laser pulse, a counter-propagating laser field, or a magnetic undulator. Other LWFA-based light sources include bremsstrahlung and terahertz radiation. Here, we first evaluate the performance of each of these light sources, and compare them with more conventional approaches, including radio frequency accelerators or other laser-driven sources. We have then identified applications, which we discuss in details, in a broad range of fields: medical and biological applications, military, defense and industrial applications, and condensed matter and high energy density science.

  1. Using the Overhead Projector as a Light Source for Physics Demonstrations

    Science.gov (United States)

    Mak, Se-Yuen

    2006-01-01

    This article illustrates how the overhead projector can be used as a light source in some peculiar ways for physics demonstrations. Five examples are included: (1) Study of chromatic aberration; (2) Making giant Newton's rings; (3) Comparison of the rate of heat absorption by different surfaces; (4) Demonstration of greenhouse effect; and (5)…

  2. Spectral matching research for light-emitting diode-based neonatal jaundice therapeutic device light source

    Science.gov (United States)

    Gan, Ruting; Guo, Zhenning; Lin, Jieben

    2015-09-01

    To decrease the risk of bilirubin encephalopathy and minimize the need for exchange transfusions, we report a novel design for light source of light-emitting diode (LED)-based neonatal jaundice therapeutic device (NJTD). The bilirubin absorption spectrum in vivo was regarded as target. Based on spectral constructing theory, we used commercially available LEDs with different peak wavelengths and full width at half maximum as matching light sources. Simple genetic algorithm was first proposed as the spectral matching method. The required LEDs number at each peak wavelength was calculated, and then, the commercial light source sample model of the device was fabricated to confirm the spectral matching technology. In addition, the corresponding spectrum was measured and the effect was analyzed finally. The results showed that fitted spectrum was very similar to the target spectrum with 98.86 % matching degree, and the actual device model has a spectrum close to the target with 96.02 % matching degree. With higher fitting degree and efficiency, this matching algorithm is very suitable for light source matching technology of LED-based spectral distribution, and bilirubin absorption spectrum in vivo will be auspicious candidate for the target spectrum of new LED-based NJTD light source.

  3. Optimization of light sources for prostate photodynamic therapy.

    Science.gov (United States)

    Altschuler, Martin D; Zhu, Timothy C; Li, Jun; Hahn, Stephen M

    2005-04-22

    To deliver uniform photodynamic dose to the prostate gland, it is necessary to develop algorithms that optimize the location and strength (emitted power × illumination time) of each light source. Since tissue optical properties may change with time, rapid (almost real-time) optimization is desirable. We use the Cimmino algorithm because it is fast, linear, and always converges reliably. A phase I motexafin lutetium (MLu)-mediated photodynamic therapy (PDT) protocol is on-going at the University of Pennsylvania. The standard plan for the protocol uses equal source strength and equal spaced loading (1-cm). PDT for the prostate is performed with cylindrical diffusing fibers (CDF) of various lengths inserted to longitudinal coverage within the matrix of parallel catheters perpendicular to a base plate. We developed several search procedures to aid the user in choosing the positions, lengths, and intensities of the CDFs. The Cimmino algorithm is used in these procedures to optimize the strengths of the light catheters at each step of the iterative selection process. Maximum and minimum bounds on allowed doses to points in four volumes (prostate, urethra, rectum, and background) constrain the solutions for the strengths of the linear light sources. Uniform optical properties are assumed. To study how different opacities of the prostate would affect optimization, optical kernels of different light penetration were used. Another goal is to see whether the urethra and rectum can be spared, with minimal effect on PTV treatment delivery, by manipulating light illumination times of the sources. Importance weights are chosen beforehand for organ volumes, and normalized. Compared with the standard plan, our algorithm is shown to produce a plan that better spares the urethra and rectum and is very fast. Thus the combined selection of positions, lengths, and strengths of interstitial light sources improves outcome.

  4. High-speed OCT light sources and systems [Invited

    Science.gov (United States)

    Klein, Thomas; Huber, Robert

    2017-01-01

    Imaging speed is one of the most important parameters that define the performance of optical coherence tomography (OCT) systems. During the last two decades, OCT speed has increased by over three orders of magnitude. New developments in wavelength-swept lasers have repeatedly been crucial for this development. In this review, we discuss the historical evolution and current state of the art of high-speed OCT systems, with focus on wavelength swept light sources and swept source OCT systems. PMID:28270988

  5. PREFACE: Diagnostics for electrical discharge light sources: pushing the limits Diagnostics for electrical discharge light sources: pushing the limits

    Science.gov (United States)

    Zissis, Georges; Haverlag, Marco

    2010-06-01

    Light sources play an indispensable role in the daily life of any human being. Quality of life, health and urban security related to traffic and crime prevention depend on light and on its quality. In fact, every day approximately 30 billion electric light sources operate worldwide. These electric light sources consume almost 19% of worldwide electricity production. Finding new ways to light lamps is a challenge where the stakes are scientific, technological, economic and environmental. The production of more efficient light sources is a sustainable solution for humanity. There are many opportunities for not only enhancing the efficiency and reliability of lighting systems but also for improving the quality of light as seen by the end user. This is possible through intelligent use of new technologies, deep scientific understanding of the operating principles of light sources and knowledge of the varied human requirements for different types of lighting in different settings. A revolution in the domain of light source technology is on the way: high brightness light emitting diodes arriving in the general lighting market, together with organic LEDs (OLEDs), are producing spectacular advances. However, unlike incandescence, electrical discharge lamps are far from disappearing from the market. In addition, new generations of discharge lamps based on molecular radiators are becoming a reality. There are still many scientific and technological challenges to be raised in this direction. Diagnostics are important for understanding the fundamental mechanisms taking place in the discharge plasma. This understanding is an absolute necessity for system optimization leading to more efficient and high quality light sources. The studied medium is rather complex, but new diagnostic techniques coupled to innovative ideas and powerful tools have been developed in recent years. This cluster issue of seven papers illustrates these efforts. The selected papers cover all domains, from

  6. Advanced Light Source Activity Report 1997/1998

    International Nuclear Information System (INIS)

    Greiner, Annette

    1999-01-01

    This Lawrence Berkeley National Laboratory, Advanced Light Source (ALS) activity report for 1997/98 discusses the following topics: Introduction and Overview; Science Highlights; Facility Report; Special Events; ALS Advisory Panels 1997/98; ALS Staff 1997/98 and Facts and Figures for the year

  7. VCSELs and silicon light sources exploiting SOI grating mirrors

    DEFF Research Database (Denmark)

    Chung, Il-Sug; Mørk, Jesper

    2012-01-01

    In this talk, novel vertical-cavity laser structure consisting of a dielectric Bragg reflector, a III-V active region, and a high-index-contrast grating made in the Si layer of a silicon-on-insulator (SOI) wafer will be presented. In the Si light source version of this laser structure, the SOI gr...

  8. Prospects for Next-Generation Storage Ring Light Sources

    Science.gov (United States)

    Borland, Michael

    2015-04-01

    Storage ring light sources are among the most productive large-scale scientific user facilities in existence, owing to a combination of broad tunability, mature technology, high capacity, remarkable reliability, and high performance. The most commonly-used performance measure is the photon beam brightness, which is proportional to the flux per unit volume in six-dimensional phase space. The brightness is generally maximized by minimizing the transverse phase space area, or emittance, of the electron beam that generates the photons. Since the 1990's, most storage ring light sources have used a variant of the Chasman-Green, or double-bend-achromat (DBA), lattice, which produces transverse emittances of several nanometers. Presently, several light sources are under construction based on more challenging multi-bend-achromat (MBA) concepts, which promise an order of magnitude reduction in the emittance. Somewhat larger reductions are contemplated for upgrades of the largest facilities. This talk briefly surveys the relevant concepts in light source design, then explains both the mechanism and challenge of achieving next-generation emittances. Other factors, such as improved radiation-emitting devices, are also described. Work supported by the U.S. Department of Energy, Office of Science, under Contract No. DE-AC02-06CH11357.

  9. Compact X-ray Light Source Workshop Report

    Energy Technology Data Exchange (ETDEWEB)

    Thevuthasan, Suntharampillai; Evans, James E.; Terminello, Louis J.; Koppenaal, David W.; Manke, Kristin L.; Plata, Charity

    2012-12-01

    This report, produced jointly by EMSL and FCSD, is the result of a workshop held in September 2011 that examined the utility of a compact x-ray light source (CXLS) in addressing many scientific challenges critical to advancing energy science and technology.

  10. Research by industry at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    1995-05-01

    The world's foremost facility for research using x-rays and ultraviolet and infrared radiation, is operated by the National Synchrotron Light Source dept. This pamphlet described the participating research teams that built most of the beam lines, various techniques for studying materials, treatment of materials, and various industrial research (catalysis, pharmaceuticals, etc.)

  11. Advanced Light Source Activity Report 1997/1998

    Energy Technology Data Exchange (ETDEWEB)

    Greiner, Annette (ed.)

    1999-03-01

    This Lawrence Berkeley National Laboratory, Advanced Light Source (ALS) activity report for 1997/98 discusses the following topics: Introduction and Overview; Science Highlights; Facility Report; Special Events; ALS Advisory Panels 1997/98; ALS Staff 1997/98 and Facts and Figures for the year.

  12. The Pre-Injector Linac for the Diamond Light Source

    CERN Document Server

    Christou, C

    2004-01-01

    The Diamond Light Source is a new medium-energy high brightness synchrotron light facility which is under construction on the Rutherford Appleton Laboratory site in the U.K. The accelerator facility can be divided into three major components; a 3 GeV 561 m circumference storage ring, a full-energy booster synchrotron and a 100 MeV pre-injector linac. This paper describes the linac design and plans for operation. The linac is supplied by ACCEL Instruments GmbH under a turn-key contract, with Diamond Light Source Ltd. providing linac beam diagnostics, control system hardware and standard vacuum components. Commissioning of the linac will take place in early 2005 and user operation of the facility will commence in 2007.

  13. Adhesion of Chlamydomonas microalgae to surfaces is switchable by light

    Science.gov (United States)

    Kreis, Christian Titus; Le Blay, Marine; Linne, Christine; Makowski, Marcin Michal; Bäumchen, Oliver

    2018-01-01

    Microalgae are photoactive microbes that live in liquid-infused environments, such as soil, temporary pools and rocks, where they encounter and colonize a plethora of surfaces. Their photoactivity manifests itself in a variety of processes, including light-directed motility (phototaxis), the growth of microalgal populations, and their photosynthetic machinery. Although microbial responses to light have been widely recognized, any influence of light on cell-surface interactions remains elusive. Here, we reveal that the unspecific adhesion of microalgae to surfaces can be reversibly switched on and off by light. Using a micropipette force spectroscopy technique, we measured in vivo single-cell adhesion forces and show that the microalga's flagella provide light-switchable adhesive contacts with the surface. This light-induced adhesion to surfaces is an active and completely reversible process that occurs on a timescale of seconds. Our results suggest that light-switchable adhesiveness is a natural functionality of microalgae to regulate the transition between the planktonic and the surface-associated state, which yields an adhesive adaptation to optimize the photosynthetic efficiency in conjunction with phototaxis.

  14. New generation of light sources: Present and future

    International Nuclear Information System (INIS)

    Couprie, M.E.

    2014-01-01

    Spectroscopy and imaging in the VUV–X-ray domain are very sensitive tools for the investigation of the properties of matter [1–3]. Time-resolved studies enable to follow the movies of ultra-fast reactions. More than fifty years after the laser discovery [4], VUVX light sources are actively developed around the world. Among them, high order harmonics generated in gas, X-ray lasers, synchrotron radiation, free electron lasers are providing a wide offer, from laboratory size sources to large scale facilities, with various features, suitable for different types of experiments. The properties of these sources are here reviewed. Quest of new performances and flexibility is also discussed

  15. Light Reflection from Water Surfaces Perturbed by Falling Rain Droplets

    Science.gov (United States)

    Molesini, Giuseppe; Vannoni, Maurizio

    2009-01-01

    An account of peculiar light patterns produced by reflection in a pool under falling rain droplets was recently reported by Molesini and Vannoni (2008 Eur. J. Phys. 29 403-11). The mathematical approach, however, only covered the case of a symmetrical location of a light source and the observer's eyes with respect to the vertical of the falling…

  16. Light source depth estimation in porcine skin using spatially resolved diffuse imaging.

    Science.gov (United States)

    Brennan, Kieran A; Ruddy, Bryan P; Nielsen, Poul M F; Taberner, Andrew J

    2016-08-01

    We present an inexpensive imaging system for measuring the diffuse surface radiance profile produced by a light source within a turbid medium. The diffusion model of light propagation in multiple scattering media is used to estimate the optical properties of a sample and subsequently approximate the depth of an optical source. The system is shown to accurately estimate the relative changes in source depth in a homogeneous phantom. The absolute depth estimate may be improved with a better estimate of the optical parameters. Preliminary tests on a porcine skin sample show that the simple model can be used to roughly track the relative changes in the depth of a source in a layered medium. However, a rigorous model of the layered geometry may be required to more accurately localize a source, particularly near interfaces between tissue layers.

  17. The advanced light source: America's brightest light for science and industry

    International Nuclear Information System (INIS)

    Cross, J.; Lawler, G.

    1994-03-01

    America's brightest light comes from the Advanced Light Source (ALS), a national facility for scientific research, product development, and manufacturing. Completed in 1993, the ALS produces light in the ultraviolet and x-ray regions of the spectrum. Its extreme brightness provides opportunities for scientific and technical progress not possible anywhere else. Technology is poised on the brink of a major revolution - one in which vital machine components and industrial processes will be drastically miniaturized. Industrialized nations are vying for leadership in this revolution - and the huge economic rewards the leaders will reap

  18. Developing electron beam bunching technology for improving light sources

    International Nuclear Information System (INIS)

    Carlsten, B.E.; Chan, K.C.D.; Feldman, D.W.

    1997-01-01

    This is the final report of a three-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The goal of this project was to develop a new electron bunch compression technology, experimentally demonstrate subpicosecond compression of bunches with charges on the order of 1 nC, and to theoretically investigate fundamental limitations to electron bunch compression. All of these goals were achieved, and in addition, the compression system built for this project was used to generate 22 nm light in a plasma-radiator light source

  19. Silicon-Based Light Sources for Silicon Integrated Circuits

    Directory of Open Access Journals (Sweden)

    L. Pavesi

    2008-01-01

    Full Text Available Silicon the material per excellence for electronics is not used for sourcing light due to the lack of efficient light emitters and lasers. In this review, after having introduced the basics on lasing, I will discuss the physical reasons why silicon is not a laser material and the approaches to make it lasing. I will start with bulk silicon, then I will discuss silicon nanocrystals and Er3+ coupled silicon nanocrystals where significant advances have been done in the past and can be expected in the near future. I will conclude with an optimistic note on silicon lasing.

  20. Direct Seeded Single Frequency mid-IR OPA all Passive Light Source

    DEFF Research Database (Denmark)

    Høgstedt, Lasse; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2013-01-01

    We present a two stage pulsed mid-infrared light source based on nonlinear downconversion of light. The light source is single frequency, tunable, all passive, single moded and build with standard optical components....

  1. Visible light guided manipulation of liquid wettability on photoresponsive surfaces

    Science.gov (United States)

    Kwon, Gibum; Panchanathan, Divya; Mahmoudi, Seyed Reza; Gondal, Mohammed A.; McKinley, Gareth H.; Varanasi, Kripa K.

    2017-04-01

    Photoresponsive titania surfaces are of great interest due to their unique wettability change upon ultraviolet light illumination. However, their applications are often limited either by the inability to respond to visible light or the need for special treatment to recover the original wettability. Sensitizing TiO2 surfaces with visible light-absorbing materials has been utilized in photovoltaic applications. Here we demonstrate that a dye-sensitized TiO2 surface can selectively change the wettability towards contacting liquids upon visible light illumination due to a photo-induced voltage across the liquid and the underlying surface. The photo-induced wettability change of our surfaces enables external manipulation of liquid droplet motion upon illumination. We show demulsification of surfactant-stabilized brine-in-oil emulsions via coalescence of brine droplets on our dye-sensitized TiO2 surface upon visible light illumination. We anticipate that our surfaces will have a wide range of applications including microfluidic devices with customizable wettability, solar-driven oil-water clean-up and demulsification technologies.

  2. Influence of the Light Source and Curing Parameters on Microhardness of a Silorane-Based Dental Composite Material

    Directory of Open Access Journals (Sweden)

    Malara P.

    2016-09-01

    Full Text Available The aim of the study was to determine the influence of the light source and the light-curing parameters (the distance of the material from the light source and time of light-curing on microhardness of Flitek Silorane dental composite material. Standardized samples of Filtek Silorane material were cured using two types of Light Curing Units (LCUs – halogen and LED. The distance of the light source and time of curing differed between samples. The Knoop’s microhardness was tested using microhardness tester Micromet 5103. Using LED light curing unit allowed to achieve significantly higher microhardness of silorane-based dental material Filtek Silorane than using halogen light curing unit. Decreasing the distance from the light source to the surface of silorane-based material Filtek Silorane improved its microhardness. A prolonged curing time could compensate the drop in microhardness of Filtek Silorane material resulting from an increased distance from the light source to the surface of the material only in a limited range of intervals.

  3. Cathode R&D for Future Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Dowell, D.H.; /SLAC; Bazarov, I.; Dunham, B.; /Cornell U., CLASSE; Harkay, K.; /Argonne; Hernandez-Garcia; /Jefferson Lab; Legg, R.; /Wisconsin U., SRC; Padmore, H.; /LBL, Berkeley; Rao, T.; Smedley, J.; /Brookhaven; Wan, W.; /LBL, Berkeley

    2010-05-26

    This paper reviews the requirements and current status of cathodes for accelerator applications, and proposes a research and development plan for advancing cathode technology. Accelerator cathodes need to have long operational lifetimes and produce electron beams with a very low emittance. The two principal emission processes to be considered are thermionic and photoemission with the photocathodes being further subdivided into metal and semi-conductors. Field emission cathodes are not included in this analysis. The thermal emittance is derived and the formulas used to compare the various cathode materials. To date, there is no cathode which provides all the requirements needed for the proposed future light sources. Therefore a three part research plan is described to develop cathodes for these future light source applications.

  4. Stability and vibration control in synchrotron light source buildings

    Energy Technology Data Exchange (ETDEWEB)

    Godel, J.B.

    1991-01-01

    Synchrotron light sources have undergone three generations of development in the last two decades. The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory has two second generation'' storage rings that currently provide the world's most intense sources of photons in the VUV and X-ray spectral ranges. There are almost 90 beam lines serving a community of 2600 scientists from 370 institutions. They are engaged in basic and applied research in physics, chemistry, biology, medicine, materials science and various technologies. When design of the NSLS began in 1977, emphasis was given to the stability of the concrete slab on which the storage rings and experimental beam lines were placed. Stability is the result of controlling: vibration from sources internal and external to the building, thermal effects of air and water temperature variations, foundation settlement and contact between the slab and underlying subsoil. With the advent of new research where highly focused beams of x-rays must be placed on increasingly smaller targets located 35 meters or more from the source, and the development of x-ray lithography with resolutions approaching 0.1 micron at chip exposure stations, even greater attention to stability is required in building designs. This paper will review the results of the successful NSLS experience and give an integrated design approach that includes elements which contribute to instabilities, and the means available to reduce them to acceptable levels.

  5. Stability and vibration control in synchrotron light source buildings

    Energy Technology Data Exchange (ETDEWEB)

    Godel, J.B.

    1991-12-31

    Synchrotron light sources have undergone three generations of development in the last two decades. The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory has two ``second generation`` storage rings that currently provide the world`s most intense sources of photons in the VUV and X-ray spectral ranges. There are almost 90 beam lines serving a community of 2600 scientists from 370 institutions. They are engaged in basic and applied research in physics, chemistry, biology, medicine, materials science and various technologies. When design of the NSLS began in 1977, emphasis was given to the stability of the concrete slab on which the storage rings and experimental beam lines were placed. Stability is the result of controlling: vibration from sources internal and external to the building, thermal effects of air and water temperature variations, foundation settlement and contact between the slab and underlying subsoil. With the advent of new research where highly focused beams of x-rays must be placed on increasingly smaller targets located 35 meters or more from the source, and the development of x-ray lithography with resolutions approaching 0.1 micron at chip exposure stations, even greater attention to stability is required in building designs. This paper will review the results of the successful NSLS experience and give an integrated design approach that includes elements which contribute to instabilities, and the means available to reduce them to acceptable levels.

  6. Experimental stations at I13 beamline at Diamond Light Source

    Science.gov (United States)

    Pešić, Z. D.; De Fanis, A.; Wagner, U.; Rau, C.

    2013-03-01

    The I13 beamline of Diamond Light Source has been operational since December 2011. The beamline encompass two fully independent branches devoted to coherent imaging experiments (coherent x-ray diffraction, coherent diffraction imaging and ptychography) and x-ray imaging (in-line phase contrast imaging, tomography and full-field microscopy). This paper gives an overview of the current status of experimental stations on both branches and outlines planned developments.

  7. Experimental stations at I13 beamline at Diamond Light Source

    International Nuclear Information System (INIS)

    Pešić, Z D; Fanis, A De; Wagner, U; Rau, C

    2013-01-01

    The I13 beamline of Diamond Light Source has been operational since December 2011. The beamline encompass two fully independent branches devoted to coherent imaging experiments (coherent x-ray diffraction, coherent diffraction imaging and ptychography) and x-ray imaging (in-line phase contrast imaging, tomography and full-field microscopy). This paper gives an overview of the current status of experimental stations on both branches and outlines planned developments.

  8. Circular dichroism beamline B23 at the Diamond Light Source.

    Science.gov (United States)

    Hussain, Rohanah; Jávorfi, Tamás; Siligardi, Giuliano

    2012-01-01

    Synchrotron radiation circular dichroism (SRCD) is a well established technique in structural biology. The first UV-VIS beamline, dedicated to circular dichroism, at Diamond Light Source Ltd, a third-generation synchrotron facility in south Oxfordshire, UK, has recently become operational and it is now available for the user community. Herein the main characteristics of the B23 SRCD beamline, the ancillary facilities available for users, and some of the recent advances achieved are summarized.

  9. National Synchrotron Light Source safety-analysis report

    International Nuclear Information System (INIS)

    Batchelor, K.

    1982-07-01

    This document covers all of the safety issues relating to the design and operation of the storage rings and injection system of the National Synchrotron Light Source. The building systems for fire protection, access and egress are described together with air and other gaseous control or venting systems. Details of shielding against prompt bremstrahlung radiation and synchrotron radiation are described and the administrative requirements to be satisfied for operation of a beam line at the facility are given

  10. Status of the National Synchrotron Light Source upgrade

    International Nuclear Information System (INIS)

    Culwick, B.B.; Smith, J.D.

    1985-01-01

    The demands for real-time control, data acquisition and display from accelerators of the National Synchrotron Light Source have exceeded the capabilities of the computer control system designed in 1978. In January 1985, a workshop on control systems was held at Brookhaven, one of the purposes of which was to provide impetus and design goals for an upgrade of the NSLS control system. The resulting design is described and its status reported

  11. Magnet power supplies for the Advanced Light Source

    International Nuclear Information System (INIS)

    Jackson, L.T.; Lutz, I.C.

    1989-03-01

    The Lawrence Berkeley Laboratory (LBL) is building an Advanced Light Source (ALS) to produce synchrotron radiation. An electron linear accelerator, and a booster synchrotron are used to accelerate the electron beam to 1.5 GeV to fill the storage ring. This paper describes the power supplies used for the magnets in the booster and the storage ring and the interface requirements for computer control and monitoring the power supplies and magnet currents. 1 ref., 3 figs., 2 tabs

  12. Application research of tune measurement system in Hefei light source

    CERN Document Server

    Sun Bao Gen; Xu Hong Liang; Lu Ping; Wang Jun; Gao Yun Feng; Wang Li; LiuJinYing

    2002-01-01

    The author introduces the measurement and research of some beam parameters using tune measurement system for Hefei Light Source (HLS), which include the betatron tune, beta function, natural chromaticity, corrected chromaticity, and central frequency. Additionally, it also describes the measurement of the influence of DC clearing electrodes on the betatron tune shift and gives some measurement results. The measurement results are compared with the theoretical values and they are in good agreement

  13. Alternate Light Source Findings of Common Topical Products.

    Science.gov (United States)

    Pollitt, Erin N; Anderson, Jocelyn C; Scafide, Katherine N; Holbrook, Debra; D'Silva, Glynis; Sheridan, Daniel J

    2016-01-01

    One of the important roles of a forensic clinician is to perform examinations of patients who are victims and suspects of crime. Alternate light source (ALS) is a tool that can improve evidence collection and enhance visualization of injuries. The purpose of this study was to examine if commonly used topical products fluoresce or absorb when examined with an ALS. Second, we aimed to identify patient and examination variables that may impact findings. A convenience sample of 81 subjects was used. After the application of 14 over-the-counter products, researchers observed the participants' skin with an ALS under 18 combinations of wavelengths and colored filters. Of the 14 products viewed (n = 1458 observations per product), six were found to fluoresce under alternate light in more than 40% of observations, five fluoresced in 1%-10% of observations, and three fluoresced less than 1% of the time. One product (a makeup product) absorbed ALS light consistently (81%), and a second (a sunscreen product) absorbed in 7%, whereas the remaining 12 products produced absorption findings in less than 1% of observations. In generalized mixed linear models, absorption findings were more commonly identified in participants with light or medium skin tones when compared with those with dark skin tones. These results suggest that the presence of topical products may impact ALS findings. A thorough forensic clinical assessment should include a documented history, including assessment of potential sources of findings, to aid in interpretation.

  14. Slim planar apparatus for converting LED light into collimated polarized light uniformly emitted from its top surface.

    Science.gov (United States)

    Teng, Tun-Chien; Tseng, Li-Wei

    2014-10-20

    This study proposes a slim planar apparatus for converting nonpolarized light from a light-emitting diode (LED) into an ultra-collimated linearly polarized beam uniformly emitted from its top surface. The apparatus was designed based on a folded-bilayer configuration comprising a light-mixing collimation element, polarization conversion element, and polarization-preserving light guide plate (PPLGP) with an overall thickness of 5 mm. Moreover, the apparatus can be extended transversally by connecting multiple light-mixing collimation elements and polarization conversion elements in a side-by-side configuration to share a considerably wider PPLGP, so the apparatus can have theoretically unlimited width. The simulation results indicate that the proposed apparatus is feasible for the maximal backlight modules in 39-inch liquid crystal panels. In the case of an apparatus with a 480 × 80 mm emission area and two 8-lumen LED light sources, the average head-on polarized luminance and spatial uniformity over the emission area was 5000 nit and 83%, respectively; the vertical and transverse angular distributions of the emitting light were only 5° and 10°, respectively. Moreover, the average degree of polarization and energy efficiency of the apparatus were 82% and 72%, respectively. As compared with the high-performance ultra-collimated nonpolarized backlight module proposed in our prior work, not only did the apparatus exhibit outstanding optical performance, but also the highly polarized light emissions actually increased the energy efficiency by 100%.

  15. Stray light in cone beam optical computed tomography: II. Reduction using a convergent light source.

    Science.gov (United States)

    Dekker, Kurtis H; Battista, Jerry J; Jordan, Kevin J

    2016-04-07

    Optical cone beam computed tomography (CBCT) using a broad beam and CCD camera is a fast method for densitometry of 3D optical gel dosimeters. However, diffuse light sources introduce considerable stray light into the imaging system, leading to underestimation of attenuation coefficients and non-uniformities in CT images unless corrections are applied to each projection image. In this study, the light source of a commercial optical CT scanner is replaced with a convergent cone beam source consisting of almost exclusively image forming primary rays. The convergent source is achieved using a small isotropic source and a Fresnel lens. To characterize stray light effects, full-field cone beam CT imaging is compared to fan beam CT (FBCT) using a 1 cm high fan beam aperture centered on the optic axis of the system. Attenuating liquids are scanned within a large 96 mm diameter uniform phantom and in a small 13.5 mm diameter finger phantom. For the uniform phantom, cone and fan beam CT attenuation coefficients agree within a maximum deviation of (1  ±  2)% between mean values over a wide range from 0.036 to 0.43 cm(-1). For the finger phantom, agreement is found with a maximum deviation of (4  ±  2)% between mean values over a range of 0.1-0.47 cm(-1). With the convergent source, artifacts associated with refractive index mismatch and vessel optical features are more pronounced. Further optimization of the source size to achieve a balance between quantitative accuracy and artifact reduction should enable practical, accurate 3D dosimetry, avoiding time consuming 3D scatter measurements.

  16. Waste-surface mapping of the Fernald K-65 silos using a structured light measurement system

    International Nuclear Information System (INIS)

    Burks, B.L.; DePiero, F.W.; Dinkins, M.A.; Rowe, J.C.; Selleck, C.B.; Jacoboski, D.L.

    1992-10-01

    A remotely operated surface-mapping measurement system was developed by the Robotics ampersand Process Systems Division at Oak Ridge National Laboratory for use in the K-65 waste-storage silos at Fernald, Ohio. The mapping system used three infrared line-generating laser diodes as illumination sources and three high-resolution, low-lux, calibrated, black-and-white, charge-coupled-device video cameras as receivers. These components were combined to form structured light source range and direction sensors with six different possible emitter-receiver pairs. A technology demonstration and predeployment tests were performed at Fernald using the empty Silo 4 into which was placed rectangular objects of known dimensions. These objects were scanned by the structured light sources to demonstrate functionality and verify that the system was giving sufficiently accurate range data in three dimensions. The structured light sources were deployed in Silos 1 and 2 to scan the waste surfaces. The resulting data were merged to create three-dimensional maps of those surfaces. A bentonite clay cap was placed over the waste surfaces and surface maps were obtained. The change in surface height before and after bentonite addition was utilized as a measure of clay cap thickness

  17. A directly cooled grating substrate for ALS [Advanced Light Source] undulator beam lines

    International Nuclear Information System (INIS)

    DiGennaro, R.; Swain, T.

    1989-08-01

    Design analyses using finite element methods are presented for thermal distortion of water-cooled diffraction grating substrates for a potential application at the LBL Advanced Light Source, demonstrating that refinements in cooling channel configuration and heat flux distribution can significantly reduce optical surface distortion with high heat loads. Using an existing grating substrate design, sensitivity of tangential slope errors due to thermal distortion is evaluated for a variety of thermal boundary conditions, including coolant flow rate and heat transfer film coefficients, surface illumination area and heat distribution profile, and location of the convection cooling surfaces adjacent to the heated region. 1 ref., 5 figs., 2 tabs

  18. Sole-Source Lighting for Controlled-Environment Agriculture

    Science.gov (United States)

    Mitchell.Cary; Stutte, Gary W.

    2015-01-01

    Since plants on Earth evolved under broad-spectrum solar radiation, anytime they are grown exclusively under electric lighting that does not contain all wavelengths in similar proportion to those in sunlight, plant appearance and size could be uniquely different. Nevertheless, plants have been grown for decades under fluorescent (FL) (1) + incandescent (IN) (2) lamps as a sole source of lighting (SSL), and researchers have become comfortable that, in certain proportions of FL + IN for a given species, plants can appear "normal" relative to their growth outdoors. The problem with using such traditional SSLs for commercial production typically is short lamp lifespans and not obtaining enough photosynthetically active radiation (PAR, 400-700 nm) when desired. These limitations led to supplementation of FL + IN lamp outputs with longer-lived, high-intensity discharge (HID) lamps in growth chambers (3). As researchers became comfortable that mixes of orange-biased high-pressure sodium (HPS) and blue-biased metal halide (MH) HIDs together also could give normal plant growth at higher intensities, growth chambers and phytotrons subsequently were equipped mainly with HID lamps, with their intense thermal output filtered out by ventilated light caps or thermal-controlled water barriers. For the most part, IN and HID lamps have found a home in commercial protected horticulture, usually for night-break photoperiod lighting (IN) or for seasonal supplemental lighting (mostly HPS) in greenhouses. However, lack of economically viable options for SSL have held back aspects of year-round indoor agriculture from taking off commercially.

  19. Near Infrared Photoimmunotherapy with Combined Exposure of External and Interstitial Light Sources.

    Science.gov (United States)

    Maruoka, Yasuhiro; Nagaya, Tadanobu; Sato, Kazuhide; Ogata, Fusa; Okuyama, Shuhei; Choyke, Peter L; Kobayashi, Hisataka

    2018-02-21

    Near infrared photoimmunotherapy (NIR-PIT) is a new target-cell-specific cancer treatment that induces highly selective necrotic/immunogenic cell death after systemic administration of a photoabsorber antibody conjugate and subsequent NIR light exposure. However, the depth of NIR light penetration in tissue (approximately 2 cm) with external light sources limits the therapeutic effects of NIR-PIT. Interstitial light exposure using cylindrical diffusing optical fibers can overcome this limitation. The purpose in this study was to compare three NIR light delivery methods for treating tumors with NIR-PIT using a NIR laser system at an identical light energy; external exposure alone, interstitial exposure alone, and the combination. Panitumumab conjugated with the photoabsorber IRDye-700DX (pan-IR700) was intravenously administered to mice with A431-luc xenografts which are epithelial growth factor receptor (EGFR) positive. One and 2 days later, NIR light was administered to the tumors using one of three methods. Interstitial exposure alone and in combination with external sources showed the greatest decrease in bioluminescence signal intensity. Additionally, the combination of external and interstitial NIR light exposure showed significantly greater tumor size reduction and prolonged survival after NIR-PIT compared to external exposure alone. This result suggested that the combination of external and interstitial NIR light exposure was more effective than externally applied light alone. Although external exposure is the least invasive means of delivering light, the combination of external and interstitial exposures produces superior therapeutic efficacy in tumors greater than 2 cm in depth from the tissue surface.

  20. Simulation of multicomponent light source for optical-electronic system of color analysis objects

    Science.gov (United States)

    Peretiagin, Vladimir S.; Alekhin, Artem A.; Korotaev, Valery V.

    2016-04-01

    Development of lighting technology has led to possibility of using LEDs in the specialized devices for outdoor, industrial (decorative and accent) and domestic lighting. In addition, LEDs and devices based on them are widely used for solving particular problems. For example, the LED devices are widely used for lighting of vegetables and fruit (for their sorting or growing), textile products (for the control of its quality), minerals (for their sorting), etc. Causes of active introduction LED technology in different systems, including optical-electronic devices and systems, are a large choice of emission color and LED structure, that defines the spatial, power, thermal and other parameters. Furthermore, multi-element and color devices of lighting with adjustable illumination properties can be designed and implemented by using LEDs. However, devices based on LEDs require more attention if you want to provide a certain nature of the energy or color distribution at all the work area (area of analysis or observation) or surface of the object. This paper is proposed a method of theoretical modeling of the lighting devices. The authors present the models of RGB multicomponent light source applied to optical-electronic system for the color analysis of mineral objects. The possibility of formation the uniform and homogeneous on energy and color illumination of the work area for this system is presented. Also authors showed how parameters and characteristics of optical radiation receiver (by optical-electronic system) affect on the energy, spatial, spectral and colorimetric properties of a multicomponent light source.

  1. A NEW THERMIONIC RF ELECTRON GUN FOR SYNCHROTRON LIGHT SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Kutsaev, Sergey; Agustsson, R.; Hartzell, J; Murokh, A.; Nassiri, A.; Savin, E.; Smirnov, A.V.; Smirnov, A. Yu; Sun, Y.; Verma, A; Waldschmidt, Geoff; Zholents, A.

    2017-06-02

    A thermionic RF gun is a compact and efficient source of electrons used in many practical applications. RadiaBeam Systems and the Advanced Photon Source at Argonne National Laboratory collaborate in developing of a reliable and robust thermionic RF gun for synchrotron light sources which would offer substantial improvements over existing thermionic RF guns and allow stable operation with up to 1A of beam peak current at a 100 Hz pulse repetition rate and a 1.5 μs RF pulse length. In this paper, we discuss the electromagnetic and engineering design of the cavity and report the progress towards high power tests of the cathode assembly of the new gun.

  2. A lighting assembly based on red and blue light-emitting diodes as a lighting source for space agriculture

    Science.gov (United States)

    Avercheva, Olga; Berkovich, Yuliy A.; Smolyanina, Svetlana; Bassarskaya, Elizaveta; Zhigalova, Tatiana; Ptushenko, Vasiliy; Erokhin, Alexei

    Light-emitting diodes (LEDs) are a promising lighting source for space agriculture due to their high efficiency, longevity, safety, and other factors. Assemblies based on red and blue LEDs have been recommended in literature, although not all plants show sufficient productivity in such lighting conditions. Adding of green LEDs proposed in some works was aimed at psychological support for the crew, and not at the improvement of plant growth. We studied the growth and the state of the photosynthetic apparatus in Chinese cabbage (Brassica chinensis L.) plants grown under red (650 nm) and blue (470 nm) light-emitting diodes (LEDs). Plants grown under a high-pressure sodium lamp (HPS lamp) were used as a control. The plants were illuminated with two photosynthetic photon flux levels: nearly 400 µE and about 100 µE. Plants grown under LEDs with 400 µE level, as compared to control plants, showed lower fresh weight, edible biomass, growth rate, and sugar content. The difference in fresh weight and edible biomass was even more pronounced in plants grown with 100 µE level; the data indicate that the adaptability of the test plants to insufficient lighting decreased. Under LEDs, we observed the decreasing of root growth and the absence of transition to the flowering stage, which points to a change in the hormonal balance in plants grown in such lighting conditions. We also found differences in the functioning of the photosynthetic apparatus and its reaction to a low lighting level. We have concluded that a lighting assembly with red and blue LEDs only is insufficient for the plant growth and productivity, and can bring about alterations in their adaptive and regulatory mechanisms. Further studies are needed to optimize the lighting spectrum for space agriculture, taking into account the photosynthetic, phototropic and regulatory roles of light. Using white LEDs or adding far-red and green LEDs might be a promising approach.

  3. A light reflecting apparatus including a multi-aberration light reflecting surface

    Science.gov (United States)

    Sawicki, R.H.; Sweatt, W.

    1985-11-21

    A light reflecting apparatus including a multi-aberration bendable light reflecting surface is disclosed herein. This apparatus includes a structural assembly comprised of a rectangular plate which is resiliently bendable, to a limited extent, and which has a front side defining the multi-aberration light reflecting surface and an opposite back side, and a plurality of straight leg members rigidly connected with the back side of the plate and extending rearwardly therefrom. The apparatus also includes a number of different adjustment mechanisms, each of which is connected with specific ones of the leg members. These mechanisms are adjustably movable in different ways for applying corresponding forces to the leg members in order to bend the rectangular plate and light reflecting surface into different predetermined curvatures and which specifically include quadratic and cubic curvatures corresponding to different optical aberrations.

  4. Validation of ultraviolet, infrared, and narrow band light alternate light sources for detection of bruises in a pigskin model.

    Science.gov (United States)

    Olds, Kelly; Byard, Roger W; Winskog, Calle; Langlois, Neil E I

    2016-12-01

    Alternate light sources such as ultraviolet, narrow band, and infrared have been used in an attempt to reveal the presence of bruising that is not otherwise apparent (inapparent). The following study evaluates the ability of alternate light sources to enhance visibility of bruises by employing an objective assessment of digital photography images in conjunction with histology. A pigskin model was employed with bruises created by injection of blood to be not visible or barely visible (inapparent) under white light. The pigskin was photographed using alternate light source illumination. Images were assessed using the program Fiji ® to measure enhancement in terms of bruise length (cm). Photography results were compared with histology to confirm the presence of bruising. Violet and blue light sources produced the greatest enhancement, both with a p light sources in this study, indicating that light sources are not specific, and that their use to enhance the visibility of bruising should be undertaken with caution.

  5. Light source comprising a common substrate, a first led device and a second led device

    Science.gov (United States)

    Choong, Vi-En

    2010-02-23

    At least one stacked organic or polymeric light emitting diode (PLEDs) devices to comprise a light source is disclosed. At least one of the PLEDs includes a patterned cathode which has regions which transmit light. The patterned cathodes enable light emission from the PLEDs to combine together. The light source may be top or bottom emitting or both.

  6. Linac Coherent Light Source (LCLS) Design Study Report

    Energy Technology Data Exchange (ETDEWEB)

    Cornacchia, Massimo

    1998-12-04

    The Stanford Linear Accelerator Center, in collaboration with Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, is proposing to build a Free-Electron-Laser (FEL) R and D facility operating in the wavelength range 1.5-15 {angstrom}. This FEL, called the ''Linac Coherent Light Source'' (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. Starting in FY 1998, the first two-thirds of the SLAC linac will be used for injection into the B factory. This leaves the last one-third free for acceleration to 15 GeV. The LCLS takes advantage of this opportunity, opening the way for the next generation of synchrotron light sources with largely proven technology and cost effective methods. This proposal is consistent with the recommendations of the Report of the Basic Energy Sciences Advisory Committee (Synchrotron Radiation Light Source Working Group, October 18-19, 1997). The report recognizes that ''fourth-generation x-ray sources...will in all likelihood be based on the free electron laser concepts. If successful, this technology could yield improvements in brightness by many orders of magnitude.'' This Design Study, the authors believe, confirms the feasibility of constructing an x-ray FEL based on the SLAC linac. Although this design is based on a consistent and feasible set of parameters, some components require more research and development to guarantee the performance. Given appropriate funding, this R and D phase can be completed in 2 years.

  7. The Use of Light-Emitting Diodes (LEDs) as Green and Red/Far-Red Light Sources in Plant Physiology.

    Science.gov (United States)

    Jackson, David L.; And Others

    1985-01-01

    The use of green, red, and far-red light-emitting diodes (LEDs) as light sources for plant physiological studies is outlined and evaluated. Indicates that LED lamps have the advantage over conventional light sources in that they are lightweight, low-cost, portable, easily constructed, and do not require color filters. (Author/DH)

  8. New Implementation of an SX700 Undulator Beamline at the Advanced Light Source

    International Nuclear Information System (INIS)

    Warwick, T.; Andresen, N.; Comins, J.; Kortright, J.B.; McKean, J.P.; Padmore, H.A.; Shuh, D.K.; Stevens, T.; Tyliszczak, T.; Kaznacheyev, K.

    2004-01-01

    A newly engineered implementation of a collimated SX700-style beam line for soft x-rays is described. This facility is operational at the Advanced Light Source and delivers high brightness undulator beams to a scanning zone plate microscope and to an array of end stations for x-ray spectroscopic studies of wet surfaces. Switching between branches is motorized, servo-steering systems maintain throughput and the monochromator works together with the elliptical undulator for a fully automated facility

  9. New implementation of an SX700 undulator beamline at the Advanced Light Source

    International Nuclear Information System (INIS)

    Warwick, T.; Andresen, N.; Comins, J.; Kaznacheyev, K.; Kortright, J.B.; McKean, P.J.; Padmore, H.A.; Shuh, D.K.; Stevens, T.; Tyliszczak, T.

    2004-01-01

    A newly engineered implementation of a collimated SX700-style beam line for soft x-rays is described. This facility is operational at the Advanced Light Source and delivers high brightness undulator beams to a scanning zone plate microscope and to an array of end stations for x-ray spectroscopic studies of wet surfaces. Switching between branches is motorized, servo-steering systems maintain throughput and the monochromator works together with the elliptical undulator for a fully automated facility

  10. Revised accident source terms for light-water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Soffer, L. [Nuclear Regulatory Commission, Washington, DC (United States)

    1995-02-01

    This paper presents revised accident source terms for light-water reactors incorporating the severe accident research insights gained in this area over the last 15 years. Current LWR reactor accident source terms used for licensing date from 1962 and are contained in Regulatory Guides 1.3 and 1.4. These specify that 100% of the core inventory of noble gases and 25% of the iodine fission products are assumed to be instantaneously available for release from the containment. The chemical form of the iodine fission products is also assumed to be predominantly elemental iodine. These assumptions have strongly affected present nuclear air cleaning requirements by emphasizing rapid actuation of spray systems and filtration systems optimized to retain elemental iodine. A proposed revision of reactor accident source terms and some im implications for nuclear air cleaning requirements was presented at the 22nd DOE/NRC Nuclear Air Cleaning Conference. A draft report was issued by the NRC for comment in July 1992. Extensive comments were received, with the most significant comments involving (a) release fractions for both volatile and non-volatile species in the early in-vessel release phase, (b) gap release fractions of the noble gases, iodine and cesium, and (c) the timing and duration for the release phases. The final source term report is expected to be issued in late 1994. Although the revised source terms are intended primarily for future plants, current nuclear power plants may request use of revised accident source term insights as well in licensing. This paper emphasizes additional information obtained since the 22nd Conference, including studies on fission product removal mechanisms, results obtained from improved severe accident code calculations and resolution of major comments, and their impact upon the revised accident source terms. Revised accident source terms for both BWRS and PWRS are presented.

  11. Electrically driven surface plasmon light-emitting diodes

    DEFF Research Database (Denmark)

    Fadil, Ahmed; Ou, Yiyu; Iida, Daisuke

    We investigate device performance of GaN light-emitting diodes (LEDs) with a 30-nm p-GaN layer. The metallization used to separate the p-contact from plasmonic metals, reveals limitations on current spreading which reduces surface plasmonic enhancement.......We investigate device performance of GaN light-emitting diodes (LEDs) with a 30-nm p-GaN layer. The metallization used to separate the p-contact from plasmonic metals, reveals limitations on current spreading which reduces surface plasmonic enhancement....

  12. Excitation of anodized alumina films with a light source

    DEFF Research Database (Denmark)

    Aggerbeck, Martin; Canulescu, Stela; Rechendorff, K.

    Optical properties of anodized aluminium alloys were determined by optical diffuse reflectance spectroscopy of such films. Samples with different concentrations of dopants were excited with a white-light source combined with an integrating sphere for fast determination of diffuse reflectance....... The UV-VIS reflectance of Ti-doped anodized aluminium films was measured over the wavelength range of 200 nm to 900 nm. Titanium doped-anodized aluminium films with 5-15 wt% Ti were characterized. Changes in the diffuse light scattering of doped anodized aluminium films, and thus optical appearance......, with doping are discussed. Using the Kubelka-Munk model on the diffuse reflectance spectra of such films, the bandgap Eg of the oxide alloys can be determined....

  13. Exact solution to surface displacement associated with sources ...

    African Journals Online (AJOL)

    user

    Usually an exact solution to the surface displacement in an elastic half space is available for sources parallel to the surface. Here we consider a buried elliptic source ... used Laplace–Hankel mixed transform and transfer matrix techniques along with the Fast Hankel transform algorithm for an impulsive ring source within a ...

  14. Progress in extremely high brightness LED-based light sources

    Science.gov (United States)

    Hoelen, Christoph; Antonis, Piet; de Boer, Dick; Koole, Rolf; Kadijk, Simon; Li, Yun; Vanbroekhoven, Vincent; Van De Voorde, Patrick

    2017-09-01

    Although the maximum brightness of LEDs has been increasing continuously during the past decade, their luminance is still far from what is required for multiple applications that still rely on the high brightness of discharge lamps. In particular for high brightness applications with limited étendue, e.g. front projection, only very modest luminance values in the beam can be achieved with LEDs compared to systems based on discharge lamps or lasers. With dedicated architectures, phosphor-converted green LEDs for projection may achieve luminance values up to 200-300 Mnit. In this paper we report on the progress made in the development of light engines based on an elongated luminescent concentrator pumped by blue LEDs. This concept has recently been introduced to the market as ColorSpark High Lumen Density LED technology. These sources outperform the maximum brightness of LEDs by multiple factors. In LED front projection, green LEDs are the main limiting factor. With our green modules, we now have achieved peak luminance values of 2 Gnit, enabling LED-based projection systems with over 4000 ANSI lm. Extension of this concept to yellow and red light sources is presented. The light source efficiency has been increased considerably, reaching 45-60 lm/W for green under practical application conditions. The module architecture, beam shaping, and performance characteristics are reviewed, as well as system aspects. The performance increase, spectral range extensions, beam-shaping flexibility, and cost reductions realized with the new module architecture enable a breakthrough in LED-based projection systems and in a wide variety of other high brightness applications.

  15. Practical Investigation for Road Lighting using Renewable Energy Sources

    Directory of Open Access Journals (Sweden)

    Maged A. Abu Adma

    2017-12-01

    Full Text Available Abstract - Hybrid renewable energy systems are recently used to counteract the limitations of solar and wind as solo renewable energy sources due to adverse weather conditions. This study explains a design of a fully independent -off grid- hybrid solar and wind road lighting system according to geography and weather conditions recorded from the National Research Institute of Astronomy and Geophysics. The computerized model is designed step by step by the aid of Simulink-Matlab and the simulation was successfully run to show the performance of each module.

  16. Ultrabright Laser-based MeV-class Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Albert, F; Anderson, G; Anderson, S; Bayramian, A; Berry, B; Betts, S; Dawson, J; Ebbers, C; Gibson, D; Hagmann, C; Hall, J; Hartemann, F; Hartouni, E; Heebner, J; Hernandez, J; Johnson, M; Messerly, M; McNabb, D; Phan, H; Pruet, J; Semenov, V; Shverdin, M; Sridharan, A; Tremaine, A; Siders, C W; Barty, C J

    2008-04-02

    We report first light from a novel, new source of 10-ps 0.776-MeV gamma-ray pulses known as T-REX (Thomson-Radiated Extreme X-rays). The MeV-class radiation produced by TREX is unique in the world with respect to its brightness, spectral purity, tunability, pulse duration and laser-like beam character. With T-REX, one can use photons to efficiently probe and excite the isotope-dependent resonant structure of atomic nucleus. This ability will be enabling to an entirely new class of isotope-specific, high resolution imaging and detection capabilities.

  17. Status report on the Advanced Light Source control system, 1993

    International Nuclear Information System (INIS)

    Young, J.; Brown, W. Jr.; Cork, C.

    1993-10-01

    The Advanced Light Source (ALS), under construction for the past seven years, has become operational. The accelerator has been successfully commissioned using a control system based on hundreds of controllers of our own design and high performance personal computers which are the operator interface. The first beamlines are being commissioned using a control system based on VME hardware and the Experimental Physics and Industrial Control System (EPICS) software. The two systems are being integrated, and this paper reports on the current work being done

  18. Spectral confocal reflection microscopy using a white light source

    Science.gov (United States)

    Booth, M.; Juškaitis, R.; Wilson, T.

    2008-08-01

    We present a reflection confocal microscope incorporating a white light supercontinuum source and spectral detection. The microscope provides images resolved spatially in three-dimensions, in addition to spectral resolution covering the wavelength range 450-650nm. Images and reflection spectra of artificial and natural specimens are presented, showing features that are not normally revealed in conventional microscopes or confocal microscopes using discrete line lasers. The specimens include thin film structures on semiconductor chips, iridescent structures in Papilio blumei butterfly scales, nacre from abalone shells and opal gemstones. Quantitative size and refractive index measurements of transparent beads are derived from spectral interference bands.

  19. Simulated nuclear optical signatures using explosive light sources (ELS)

    International Nuclear Information System (INIS)

    Glaser, R.F.

    1979-05-01

    Four Explosive Light Source (aluminium powder and oxygen) tests were conducted on the test range at Sandia Laboratories in Albuquerque (SLA) from 28 February through 7 March 1978. Although several types of measuring devices were used, the report documents only the optical time histories measured by the bhangmeters and the NBDS, and explains the conclusions reached. In general, the four shots made it possible to gather clear-air optical transmission data, determine the suitability of ELS to simulate the optical effects of a nuclear burst, and provide experience for the larger scale ELS tests to be conducted at Fort Ord, CA in April

  20. Risk of retina damage from high intensity light sources

    Energy Technology Data Exchange (ETDEWEB)

    Pollak, V.A.; Romanchuk, K.G.

    1980-05-01

    The risk of thermal damage to the retina of the eye by exposure to excesive light intensities from continuous and pulsed man-made sources is discussed. The probability of injury increases, the larger the radiant power absorbed by the retina and the smaller the size of the retinal image of the source. A method of estimating the temperature increase of the immediately affected area of the retina is presented. The time constants involved are also briefly considered. Using numerical values from literature for the relevant parameters of the eye, threshold values for a variety of conditions can be established. Below these values little risk of retina damage should exist. The degree of hazard when these values are exceeded depends upon the circumstances. A case study of a welding accident showed good agreement between the conclusions of the theoretical analysis and clinical findings.

  1. Introduction to special section on future light sources

    Energy Technology Data Exchange (ETDEWEB)

    Winick, Herman

    2003-07-09

    This special section of NIM is devoted to an overview of progress in the development of powerful new sources of X-radiation for use in advanced studies in the physical, chemical, and biological sciences. Included here are four articles on future light sources that were originally published in 2002 in the SLAC Beam Line quarterly magazine. We are grateful to SLAC and the authors of these articles for their agreement to reprint them in volume 500 of NIM. As is common for the Beam Line, these articles contain no references to reports in the literature and do not attempt to be comprehensive overviews of the field. Therefore, we offer this expanded overview and introduction in which we attempt to briefly cover recent developments and topics not covered in the four articles.

  2. Inverse free electron laser accelerator for advanced light sources

    Directory of Open Access Journals (Sweden)

    J. P. Duris

    2012-06-01

    Full Text Available We discuss the inverse free electron laser (IFEL scheme as a compact high gradient accelerator solution for driving advanced light sources such as a soft x-ray free electron laser amplifier or an inverse Compton scattering based gamma-ray source. In particular, we present a series of new developments aimed at improving the design of future IFEL accelerators. These include a new procedure to optimize the choice of the undulator tapering, a new concept for prebunching which greatly improves the fraction of trapped particles and the final energy spread, and a self-consistent study of beam loading effects which leads to an energy-efficient high laser-to-beam power conversion.

  3. Semiconductor Nanomembranes for Quantum Photonics: Quantum Light Sources and Optomechanics

    DEFF Research Database (Denmark)

    Liu, Jin

    This thesis describes the fabrication and characterizations of semiconductor nanomembranes, i.e., gallium arsenide (GaAs) photonic crystal (PC) and optomechanical nanomemebranes. Processing techniques are developed and optimized in order to fabricate PC membranes for quantum light sources......-record mechanical Q-factor up to 1 million have been fabricated with two step selective wet etches. These optomechanical naonmembranes exhibit superb performances in cavity optomechanical cooling experiments in which a mechanical mode has been cooled from room temperature to 4 K. The interaction between single...... quantum dots (QDs) and PC cavities has been modeled in the framework of Jaynes-Cummings model (JCM) with the focus on single artificial atom lasers. In the experiments, a highly efficient single photon source with a collection efficiency up to 38% has been achieved and detailed measurements suggest...

  4. Penning plasma based simultaneous light emission source of visible and VUV lights

    Energy Technology Data Exchange (ETDEWEB)

    Vyas, G. L., E-mail: glvyas27@gmail.com [Manipal University Jaipur (India); Prakash, R.; Pal, U. N. [CSIR-Central Electronics and Engineering Research Institute, Microwave Tubes Division (India); Manchanda, R. [Institute for Plasma Research (India); Halder, N. [Manipal University Jaipur (India)

    2016-06-15

    In this paper, a laboratory-based penning plasma discharge source is reported which has been developed in two anode configurations and is able to produce visible and VUV lights simultaneously. The developed source has simultaneous diagnostics facility using Langmuir probe and optical emission spectroscopy. The two anode configurations, namely, double ring and rectangular configurations, have been studied and compared for optimum use of the geometry for efficient light emissions and recording. The plasma is produced using helium gas and admixture of three noble gases including helium, neon, and argon. The source is capable to produce eight spectral lines for pure helium in the VUV range from 20 to 60 nm and total 24 spectral lines covering the wavelength range 20–106 nm for the admixture of gases. The large range of VUV lines is generated from gaseous admixture rather from the sputtered materials. The recorded spectrum shows that the plasma light radiations in both visible and VUV range are larger in double ring configuration than that of the rectangular configurations at the same discharge operating conditions. To clearly understand the difference, the imaging of the discharge using ICCD camera and particle-in-cell simulation using VORPAL have also been carried out. The effect of ion diffusion, metastable collision with the anode wall and the nonlinear effects are correlated to explain the results.

  5. The sparkle of the eye: the impact of ocular surface wetness on corneal light reflection.

    Science.gov (United States)

    Goto, Eiki; Dogru, Murat; Sato, Enrique Adan; Matsumoto, Yukihiro; Takano, Yoji; Tsubota, Kazuo

    2011-04-01

    To measure the sparkle of the human eye evaluated by the intensity of corneal light reflection in normal subjects and dry eye patients to investigate whether ocular surface wetness has an impact on the sparkle of the eye. Prospective case-control study. We examined a consecutive series of eight dry eye patients with Sjögren syndrome (SS, 15 eyes), as well as eight normal subjects (16 eyes). The specular corneal surface light reflection was quantitatively measured with an ophthalmic slit-lamp microscope and image capturing system under fixed conditions of light source, incident angle, and detector sensitivity. The intensity of images from subjects' corneal light reflection was quantified with image analysis software along with the measurement of grade of self-reported brilliancy of the eye, corneal fluorescein staining score, tear film break-up time, and Schirmer test value. The intensity of corneal light reflection was also compared before and after dry eye treatment. The mean intensity of corneal light reflection was significantly lower in dry eye patients (125.0 ± 40.1) than normal subjects (167.6 ± 36.6, P=.004). Grade of self-reported brilliancy of the eye, corneal fluorescein staining scores, tear film break-up time, and Schirmer test values showed good correlation to the intensity of corneal light reflection. After punctal plug treatment, the intensity of corneal light reflection significantly increased from 125.0 ± 40.1 to 167.2 ± 45.0 (Plight reflection representing the sparkle of the eye was significantly more intense in normal subjects compared to dry eye patients, and was increased after punctal plug treatment. The intensity of corneal light reflection appeared to correlate well with tear film stability, volume, and ocular surface desiccation. We showed that tears contributed not only to ocular surface wetness but also to the extent of the light reflection from the eye. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Inverse Compton Light Source: A Compact Design Proposal

    Science.gov (United States)

    Deitrick, Kirsten Elizabeth

    In the last decade, there has been an increasing demand for a compact Inverse Compton Light Source (ICLS) which is capable of producing high-quality X-rays by colliding an electron beam and a high-quality laser. It is only in recent years when both SRF and laser technology have advanced enough that compact sources can approach the quality found at large installations such as the Advanced Photon Source at Argonne National Laboratory. Previously, X-ray sources were either high flux and brilliance at a large facility or many orders of magnitude lesser when produced by a bremsstrahlung source. A recent compact source was constructed by Lyncean Technologies using a storage ring to produce the electron beam used to scatter the incident laser beam. By instead using a linear accelerator system for the electron beam, a significant increase in X-ray beam quality is possible, though even subsequent designs also featuring a storage ring offer improvement. Preceding the linear accelerator with an SRF reentrant gun allows for an extremely small transverse emittance, increasing the brilliance of the resulting X-ray source. In order to achieve sufficiently small emittances, optimization was done regarding both the geometry of the gun and the initial electron bunch distribution produced off the cathode. Using double-spoke SRF cavities to comprise the linear accelerator allows for an electron beam of reasonable size to be focused at the interaction point, while preserving the low emittance that was generated by the gun. An aggressive final focusing section following the electron beam's exit from the accelerator produces the small spot size at the interaction point which results in an X-ray beam of high flux and brilliance. Taking all of these advancements together, a world class compact X-ray source has been designed. It is anticipated that this source would far outperform the conventional bremsstrahlung and many other compact ICLSs, while coming closer to performing at the levels

  7. Inverse compton light source: a compact design proposal

    Energy Technology Data Exchange (ETDEWEB)

    Deitrick, Kirsten Elizabeth [Old Dominion Univ., Norfolk, VA (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2017-05-01

    In the last decade, there has been an increasing demand for a compact Inverse Compton Light Source (ICLS) which is capable of producing high-quality X-rays by colliding an electron beam and a high-quality laser. It is only in recent years when both SRF and laser technology have advanced enough that compact sources can approach the quality found at large installations such as the Advanced Photon Source at Argonne National Laboratory. Previously, X-ray sources were either high flux and brilliance at a large facility or many orders of magnitude lesser when produced by a bremsstrahlung source. A recent compact source was constructed by Lyncean Technologies using a storage ring to produce the electron beam used to scatter the incident laser beam. By instead using a linear accelerator system for the electron beam, a significant increase in X-ray beam quality is possible, though even subsequent designs also featuring a storage ring offer improvement. Preceding the linear accelerator with an SRF reentrant gun allows for an extremely small transverse emittance, increasing the brilliance of the resulting X-ray source. In order to achieve sufficiently small emittances, optimization was done regarding both the geometry of the gun and the initial electron bunch distribution produced off the cathode. Using double-spoke SRF cavities to comprise the linear accelerator allows for an electron beam of reasonable size to be focused at the interaction point, while preserving the low emittance that was generated by the gun. An aggressive final focusing section following the electron beam's exit from the accelerator produces the small spot size at the interaction point which results in an X-ray beam of high flux and brilliance. Taking all of these advancements together, a world class compact X-ray source has been designed. It is anticipated that this source would far outperform the conventional bremsstrahlung and many other compact ICLSs, while coming closer to performing at the

  8. Surface energy and work function of the light actinides

    DEFF Research Database (Denmark)

    Kollár, J.; Vitos, Levente; Skriver, Hans Lomholt

    1994-01-01

    We have calculated the surface energy and work function of the light actinides Fr, Ra, Ac, Th, Pa, U, Np, and Pu by means of a Green's-function technique based on the linear-muffin-tin-orbitals method within the tight-binding representation. In these calculations we apply an energy functional which...

  9. Light-driven altitudinal molecular motors on surfaces

    NARCIS (Netherlands)

    London, Gabor; Carroll, Gregory T.; Fernández Landaluce, Tatiana; Pollard, Michael M.; Rudolf, Petra; Feringa, Ben L.

    2009-01-01

    A Cu(I)-catalyzed 1,3-dipolar cycloaddition was used to construct a monolayer of an altitudinal molecular motor on quartz and silicon substrates, which represents the fastest light-driven molecular motor, to date, grafted to a solid surface.

  10. Source Term Model for Fine Particle Resuspension from Indoor Surfaces

    National Research Council Canada - National Science Library

    Kim, Yoojeong; Gidwani, Ashok; Sippola, Mark; Sohn, Chang W

    2008-01-01

    This Phase I effort developed a source term model for particle resuspension from indoor surfaces to be used as a source term boundary condition for CFD simulation of particle transport and dispersion in a building...

  11. SESAME -- A light source for the Middle East

    Science.gov (United States)

    Winick, Herman

    2012-02-01

    Developed under UNESCO and modelled on CERN, SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) is an international research centre in construction in Jordan, enabling world-class research while promoting peace through scientific cooperation. Its centerpiece, a new 2.5 GeV 3rd Generation Electron Storage Ring (133m circumference, 26nm-rad emittance, 12 places for insertion devices), will provide intense light from infra-red to hard X-rays. The Council (Bahrain, Cyprus, Egypt, Iran, Israel, Jordan, Pakistan, Palestinian Authority, Turkey), provides the annual budget. Concrete shielding is complete, and a staff of 21 is installing the refurbished 0.8 GeV BESS Y I injector system, a gift from Germany. The facility can serve 25 simultaneous experiments. Beamline equipment has been provided by Daresbury (UK), the Helmholtz Assoc. (Germany), the Swiss Light Source, LURE (France), the Univ. of Liverpool, Elettra (Italy) and US labs. Jordan has contributed 3.3M, in addition to a building and land. The EU has contributed 4.8M. Commitments confirmed by Members look set to provide most of 35M needed to complete construction of the ring and 3 beamlines. A training program has been underway since 2000. See www.sesame.org.jo

  12. A squeezed light source operated under high vacuum.

    Science.gov (United States)

    Wade, Andrew R; Mansell, Georgia L; Chua, Sheon S Y; Ward, Robert L; Slagmolen, Bram J J; Shaddock, Daniel A; McClelland, David E

    2015-12-14

    Non-classical squeezed states of light are becoming increasingly important to a range of metrology and other quantum optics applications in cryptography, quantum computation and biophysics. Applications such as improving the sensitivity of advanced gravitational wave detectors and the development of space-based metrology and quantum networks will require robust deployable vacuum-compatible sources. To date non-linear photonics devices operated under high vacuum have been simple single pass systems, testing harmonic generation and the production of classically correlated photon pairs for space-based applications. Here we demonstrate the production under high-vacuum conditions of non-classical squeezed light with an observed 8.6 dB of quantum noise reduction down to 10 Hz. Demonstration of a resonant non-linear optical device, for the generation of squeezed light under vacuum, paves the way to fully exploit the advantages of in-vacuum operations, adapting this technology for deployment into new extreme environments.

  13. Science research with high-brilliance synchrotron light source

    International Nuclear Information System (INIS)

    Sanyal, Milan K.

    2013-01-01

    Synchrotron-science has changed dramatically since the development of high brilliance electron accelerator-based light sources in 1990s. In the last twenty years or so, several such facilities have come up, particularly in developed countries, as material characterizations in relevant atmosphere and protein crystallography with tiny-crystals have strong implications in industrial competitiveness. Moreover several new techniques have been developed recently over the entire spectral range of emitted light, from infra-red to high energy X-rays, which have altered our basic understanding of various materials like biomaterials, nanomaterials, soft-matter and semiconductor quantum structures. In addition, rapid development of various X-ray imaging techniques for nondestructive evaluation of compositional/structural homogeneity of engineering materials with nanometer resolution will have tremendous impact in manufacturing industries. As India becomes a developed country, it must have access to such an advanced synchrotron facility in the country that enables knowledge generation in the ever-expanding fields of design-characterization-production of advanced materials and modern medicines. Development of such state-of-the art facility will also enable us to carry out frontier-basic-research in our own country and help us to retain and bring back Indian talents to India. Here we shall discuss briefly the characteristics of a high brilliance synchrotron source and outline the nature of basic and applied science research that can be done with such a state-of-the-art facility. (author)

  14. Phase 2 safety analysis report: National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Stefan, P.

    1989-06-01

    The Phase II program was established in order to provide additional space for experiments, and also staging and equipment storage areas. It also provides additional office space and new types of advanced instrumentation for users. This document will deal with the new safety issues resulting from this extensive expansion program, and should be used as a supplement to BNL Report No. 51584 ''National Synchrotron Light Source Safety Analysis Report,'' July 1982 (hereafter referred to as the Phase I SAR). The initial NSLS facility is described in the Phase I SAR. It comprises two electron storage rings, an injection system common to both, experimental beam lines and equipment, and office and support areas, all of which are housed in a 74,000 sq. ft. building. The X-ray Ring provides for 28 primary beam ports and the VUV Ring, 16. Each port is capable of division into 2 or 3 separate beam lines. All ports receive their synchrotron light from conventional bending magnet sources, the magnets being part of the storage ring lattice. 4 refs

  15. Future Synchrotron Light Sources Based on Ultimate Storage Rings

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Yunhai; /SLAC

    2012-04-09

    The main purpose of this talk is to describe how far one might push the state of the art in storage ring design. The talk will start with an overview of the latest developments and advances in the design of synchrotron light sources based on the concept of an 'ultimate' storage ring. The review will establish how bright a ring based light source might be, where the frontier of technological challenges are, and what the limits of accelerator physics are. Emphasis will be given to possible improvements in accelerator design and developments in technology toward the goal of achieving an ultimate storage ring. An ultimate storage ring (USR), defined as an electron ring-based light source having an emittance in both transverse planes at the diffraction limit for the range of X-ray wavelengths of interest for a scientific community, would provide very high brightness photons having high transverse coherence that would extend the capabilities of X-ray imaging and probe techniques beyond today's performance. It would be a cost-effective, high-coherence 4th generation light source, competitive with one based on energy recovery linac (ERL) technology, serving a large number of users studying material, chemical, and biological sciences. Furthermore, because of the experience accumulated over many decades of ring operation, it would have the great advantage of stability and reliability. In this paper we consider the design of an USR having 10-pm-rad emittance. It is a tremendous challenge to design a storage ring having such an extremely low emittance, a factor of 100 smaller than those in existing light sources, especially such that it has adequate dynamic aperture and beam lifetime. In many ultra-low emittance designs, the injection acceptances are not large enough for accumulation of the electron beam, necessitating on-axis injection where stored electron bunches are completely replaced with newly injected ones. Recently, starting with the MAX-IV 7-bend

  16. Depolarization of light by rough surface of scattering phantoms

    Science.gov (United States)

    Tchvialeva, Lioudmila; Markhvida, Igor; Lee, Tim K.; Doronin, Alexander; Meglinski, Igor

    2013-02-01

    The growing interest in biomedical optics to the polarimetric methods push researchers to better understand of light depolarization during scattering in and on the surface of biological tissues. Here we study the depolarization of light propagated in silicone phantoms. The phantoms with variety of surface roughness and bulk optical properties are designed to imitate human skin. Free-space speckle patterns in parallel (III) and perpendicular (I⊥) direction in respect to incident polarization are used to get the depolarization ratio of backscattered light DR = (III - I⊥)/( III + I⊥). The Monte Carlo model developed in house is also applied to compare simulated DR with experimentally measured. DR dependence on roughness, concentration and size of scattering particles is analysed. A weak depolarization and negligible response to scattering of the medium are observed for phantoms with smooth surfaces, whereas for the surface roughness in order to the mean free path the depolarization ratio decreases and reveals dependence on the bulk scattering coefficient. In is shown that the surface roughness could be a key factor triggering the ability of tissues' characterization by depolarization ratio.

  17. SurfaceWater Source Protection Areas (SPAs)

    Data.gov (United States)

    Vermont Center for Geographic Information — Source Protection Area (SPA) boundaries have been located on RF 24000 & RF 25000 scale USGS topographic maps by Water Supply Division (DEC) and VT Dept of Health...

  18. Terahertz Light Source and User Area at FACET

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Z.; Li, S.Z.; Litos, M.; Fisher, A.D.; Hogan, M.J.; /SLAC

    2011-11-08

    FACET at SLAC provides high charge, high peak current, low emittance electron beam that is bunched at THz wavelength scale during its normal operation. A THz light source based coherent transition radiation (CTR) from this beam would potentially be the brightest short-pulse THz source ever constructed. Efforts have been put into building this photon source together with a user area, to provide a platform to utilize this unique THz radiation for novel nonlinear and ultrafast phenomena researches and experiments. Being a long-time underutilized portion of the electromagnetic spectrum, terahertz (100 GHz {approx} 10 THz) spectral range is experiencing a renaissance in recent years, with broad interests from chemical and biological imaging, material science, telecommunication, semiconductor and superconductor research, etc. Nevertheless, the paucity of THz sources especially strong THz radiation hinders both its commercial applications and nonlinear processes research. FACET - Facilities for Accelerator science and Experimental Test beams at SLAC - provides 23 GeV electron beam with peak currents of {approx} 20 kA that can be focused down to 100 {mu}m{sup 2} transversely. Such an intense electron beam, when compressed to sub-picosecond longitudinal bunch length, coherently radiates high intensity EM fields well within THz frequency range that are orders of magnitude stronger than those available from laboratory tabletop THz sources, which will enable a wide variety of THz related research opportunities. Together with a description of the FACET beamline and electron beam parameters, this paper will report FACET THz radiation generation via coherent transition radiation and calculated photon yield and power spectrum. A user table is being set up along the THz radiation extraction sites, and equipped with various signal diagnostics including THz power detector, Michelson interferometer, sample stages, and sets of motorized optical components. This setup will also be

  19. Investigation into Cherenkov light scattering and refraction on aerogel surface

    Science.gov (United States)

    Barnyakov, A. Yu.; Barnyakov, M. Yu.; Bobrovnikov, V. S.; Buzykaev, A. R.; Danilyuk, A. F.; Katcin, A. A.; Kirilenko, P. S.; Kononov, S. A.; Korda, D. V.; Kravchenko, E. A.; Kudryavtsev, V. N.; Kuyanov, I. A.; Onuchin, A. P.; Ovtin, I. V.; Podgornov, N. A.; Predein, A. Yu.; Prisekin, V. G.; Protsenko, R. S.; Shekhtman, L. I.

    2017-12-01

    The work concerns the development of aerogel radiators for RICH detectors. Aerogel tiles with a refractive index of 1.05 were tested with a RICH prototype on the electron beam on the VEPP-4M collider. It has been shown that polishing with silk tissue yields good surface quality, the amount of light loss at this surface being about 5-7%. The Cherenkov angle resolution was measured for a tile in two conditions: with a clean exit face and with a polished exit face. The number of photons detected was 13.3 and 12.7 for the clean and polished surfaces, respectively. The Cherenkov angle resolution for the polished surface is 55% worse, which can be explained with the forward scattering on the polished surface. A tile with a crack inside was also tested. The experimental data show that the Cherenkov angle resolution is the same for tracks crossing the crack area and in a crack-free area.

  20. Innovative roadway light source and dye combinations to improve visibility and reduce environmental impacts.

    Science.gov (United States)

    2013-04-01

    Sky glow light pollution is caused largely by reflected light off of roadway and other surfaces. The : authors investigated the feasibility of a system consisting of a specialized LED streetlight and a dyebased : roadway surface coating that would re...

  1. EDITORIAL: Special Issue on advanced and emerging light sources Special Issue on advanced and emerging light sources

    Science.gov (United States)

    Haverlag, Marco; Kroesen, Gerrit; Ferguson, Ian

    2011-06-01

    The papers in this special issue of Journal of Physics D: Applied Physics (JPhysD) originate from the 12th International Symposium on the Science and Technology of Light Sources and the 3rd International Conference on White LEDs and Solid State Lighting, held 11-16 July 2010 at Eindhoven University. Abstracts of all papers presented at this combined conference were published in the Conference Proceedings LS-WLED 2010 by FAST-LS, edited by M Haverlag, G M W Kroesen and T Taguchi. Special issues of the previous three LS conferences have been well-cited and have proven to be an important source of information for the lighting community. The 2010 LS-Symposium was a combined conference with the White LED Conference in order to enhance the scope of this conference series towards new light source technologies such as LEDs and OLEDs, and this co-operation will be continued in the future. Given the faster technology development in these areas it was also decided to shorten the interval between conferences from three to two years. Well over 200 invited presentations, landmark presentations and poster contributions were presented at the 2010 LS-Symposium. The organizing committee have selected from these a number of outstanding contributions with a high technological content and invited the authors to submit a full paper in JPhysD. The criteria were that the work should not be a repetition of the work already published in the Proceedings, but should be new, complete, within the scope of JPhysD, and meeting the normal quality standards of this journal. After peer review a combined set of 18 papers is published in this JPhysD special issue. In addition, a number of lighting-application-orientated papers will be published in a special issue of Journal of Light & Visual Environment later in 2011. The papers in this special issue of JPhysD show that research in the science and technology of light sources still covers a broad set of subject areas which includes both 'classical

  2. Light spectrum modifies the utilization pattern of energy sources in Pseudomonas sp. DR 5-09.

    Science.gov (United States)

    Gharaie, Samareh; Vaas, Lea A I; Rosberg, Anna Karin; Windstam, Sofia T; Karlsson, Maria E; Bergstrand, Karl-Johan; Khalil, Sammar; Wohanka, Walter; Alsanius, Beatrix W

    2017-01-01

    Despite the overruling impact of light in the phyllosphere, little is known regarding the influence of light spectra on non-phototrophic bacteria colonizing the leaf surface. We developed an in vitro method to study phenotypic profile responses of bacterial pure cultures to different bands of the visible light spectrum using monochromatic (blue: 460 nm; red: 660 nm) and polychromatic (white: 350-990 nm) LEDs, by modification and optimization of a protocol for the Phenotype MicroArray™ technique (Biolog Inc., CA, USA). The new protocol revealed high reproducibility of substrate utilization under all conditions tested. Challenging the non-phototrophic bacterium Pseudomonas sp. DR 5-09 with white, blue, and red light demonstrated that all light treatments affected the respiratory profile differently, with blue LED having the most decisive impact on substrate utilization by impairing respiration of 140 substrates. The respiratory activity was decreased on 23 and 42 substrates under red and white LEDs, respectively, while utilization of one, 16, and 20 substrates increased in the presence of red, blue, and white LEDs, respectively. Interestingly, on four substrates contrasting utilization patterns were found when the bacterium was exposed to different light spectra. Although non-phototrophic bacteria do not rely directly on light as an energy source, Pseudomonas sp. DR 5-09 changed its respiratory activity on various substrates differently when exposed to different lights. Thus, ability to sense and distinguish between different wavelengths even within the visible light spectrum must exist, and leads to differential regulation of substrate usage. With these results, we hypothesize that different light spectra might be a hitherto neglected key stimulus for changes in microbial lifestyle and habits of substrate usage by non-phototrophic phyllospheric microbiota, and thus might essentially stratify leaf microbiota composition and diversity.

  3. Light spectrum modifies the utilization pattern of energy sources in Pseudomonas sp. DR 5-09.

    Directory of Open Access Journals (Sweden)

    Samareh Gharaie

    Full Text Available Despite the overruling impact of light in the phyllosphere, little is known regarding the influence of light spectra on non-phototrophic bacteria colonizing the leaf surface. We developed an in vitro method to study phenotypic profile responses of bacterial pure cultures to different bands of the visible light spectrum using monochromatic (blue: 460 nm; red: 660 nm and polychromatic (white: 350-990 nm LEDs, by modification and optimization of a protocol for the Phenotype MicroArray™ technique (Biolog Inc., CA, USA. The new protocol revealed high reproducibility of substrate utilization under all conditions tested. Challenging the non-phototrophic bacterium Pseudomonas sp. DR 5-09 with white, blue, and red light demonstrated that all light treatments affected the respiratory profile differently, with blue LED having the most decisive impact on substrate utilization by impairing respiration of 140 substrates. The respiratory activity was decreased on 23 and 42 substrates under red and white LEDs, respectively, while utilization of one, 16, and 20 substrates increased in the presence of red, blue, and white LEDs, respectively. Interestingly, on four substrates contrasting utilization patterns were found when the bacterium was exposed to different light spectra. Although non-phototrophic bacteria do not rely directly on light as an energy source, Pseudomonas sp. DR 5-09 changed its respiratory activity on various substrates differently when exposed to different lights. Thus, ability to sense and distinguish between different wavelengths even within the visible light spectrum must exist, and leads to differential regulation of substrate usage. With these results, we hypothesize that different light spectra might be a hitherto neglected key stimulus for changes in microbial lifestyle and habits of substrate usage by non-phototrophic phyllospheric microbiota, and thus might essentially stratify leaf microbiota composition and diversity.

  4. High-Efficiency Nitride-Base Photonic Crystal Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    James Speck; Evelyn Hu; Claude Weisbuch; Yong-Seok Choi; Kelly McGroddy; Gregor Koblmuller; Elison Matioli; Elizabeth Rangel; Fabian Rol; Dobri Simeonov

    2010-01-31

    light into the active region of solar cells; increasing the efficiency of the phosphorous light conversion in white light LEDs etc. In addition to the technology of embedded PhC LEDs, we demonstrate a technique for improvement of the light extraction and emission directionality for existing flip-chip microcavity (thin) LEDs by introducing PhC grating into the top n-contact. Although, the performances of these devices in terms of increase of the extraction efficiency are not significantly superior compared to those obtained by other techniques like surface roughening, the use of PhC offers some significant advantages such as improved and controllable emission directionality and a process that is directly applicable to any material system. The PhC microcavity LEDs have also potential for industrial implementation as the fabrication process has only minor differences to that already used for flip-chip thin LEDs. Finally, we have demonstrated that achieving good electrical properties and high fabrication yield for these devices is straightforward.

  5. Far-infrared Beamline at the Canadian Light Source

    Science.gov (United States)

    Zhao, Jianbao; Billinghurst, Brant

    2017-06-01

    Far-infrared is a particularly useful technique for studies on lattice modes as they generally appear in the Far-infrared region. Far-infrared is also an important tool for gathering information on the electrical transport properties of metallic materials and the band gap of semiconductors. This poster will describe the horizontal microscope that has recently been built in the Far-infrared beamline at the Canadian Light Source Inc. (CLS). This microscope is specially designed for high-pressure Far-infrared absorbance and reflectance spectroscopic studies. The numerical aperture (0.5) and the long working distance (82.1 mm) in the microscope are good fits for Diamond Anvil Cell (DAC). The spectra are recorded using liquid helium cooled Si bolometer or Ge:Cu detector. The pressure in the DAC can be determined by using the fluorescence spectrometer available onsite. The Far-infrared beamline at CLS is a state-of-the-art synchrotron facility, offering significantly more brightness than conventional sources. Because of the high brightness of the synchrotron radiation, we can obtain the Far-infrared reflectance/absorbance spectra on the small samples with more throughput than with a conventional source. The Far-infrared beamline is open to users through peer review.

  6. Statistical photocalibration of photodetectors for radiometry without calibrated light sources

    Science.gov (United States)

    Yielding, Nicholas J.; Cain, Stephen C.; Seal, Michael D.

    2018-01-01

    Calibration of CCD arrays for identifying bad pixels and achieving nonuniformity correction is commonly accomplished using dark frames. This kind of calibration technique does not achieve radiometric calibration of the array since only the relative response of the detectors is computed. For this, a second calibration is sometimes utilized by looking at sources with known radiances. This process can be used to calibrate photodetectors as long as a calibration source is available and is well-characterized. A previous attempt at creating a procedure for calibrating a photodetector using the underlying Poisson nature of the photodetection required calculations of the skewness of the photodetector measurements. Reliance on the third moment of measurement meant that thousands of samples would be required in some cases to compute that moment. A photocalibration procedure is defined that requires only first and second moments of the measurements. The technique is applied to image data containing a known light source so that the accuracy of the technique can be surmised. It is shown that the algorithm can achieve accuracy of nearly 2.7% of the predicted number of photons using only 100 frames of image data.

  7. A trial fabrication of activity standard surface sources and positional standard surface sources for an imaging plate system

    International Nuclear Information System (INIS)

    Sato, Yasushi; Hino, Yoshio; Yamada, Takahiro; Matsumoto, Mikio

    2003-01-01

    An imaging plate system can detect low level activity, but quantitative analysis is difficult because there are no adequate standard surface sources. A new fabrication method was developed for standard surface sources by printing on a sheet of paper using an ink-jet printer with inks in which a radioactive material was mixed. The fabricated standard surface sources had high uniformity, high positional resolution arbitrary shapes and a broad intensity range. The standard sources were used for measurement of surface activity as an application. (H. Yokoo)

  8. The Advanced Light Source: A third-generation Synchrotron Radiation Source

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Arthur L.

    2002-08-14

    The Advanced Light Source (ALS) at the E.O. Lawrence Berkeley National Laboratory (Berkeley Lab) of the University of California is a ''third-generation'' synchrotron radiation source optimized for highest brightness at ultraviolet and soft x-ray photon energies. It also provides world-class performance at hard x-ray photon energies. Berkeley Lab operates the ALS for the United States Department of Energy as a national user facility that is available 24 hours/day around the year for research by scientists from industrial, academic, and government laboratories primarily from the United States but also from abroad.

  9. A calibrated UV-LED based light source for water purification and characterisation of photocatalysis.

    Science.gov (United States)

    Sergejevs, A; Clarke, C T; Allsopp, D W E; Marugan, J; Jaroenworaluck, A; Singhapong, W; Manpetch, P; Timmers, R; Casado, C; Bowen, C R

    2017-11-08

    Photocatalysis has a potential to become a cost effective industrial process for water cleaning. One of the most studied photocatalysts is titanium dioxide which, as a wide band gap semiconductor, requires ultraviolet (UV) light for its photoactivation. This is at the wavelengths where the efficiency of present-day light emitting diodes (LEDs) decreases rapidly, which presents a challenge in the use of UV-LEDs for commercially viable photocatalysis. There is also a need for accurate photocatalysis measurement of remediation rates of water-borne contaminants for determining optimum exposure doses in industrial applications. In response to these challenges, this paper describes a UV-LED based photocatalytic test reactor that provides a calibrated adjustable light source and pre-defined test conditions to remove as many sources of uncertainty in photocatalytic analysis as possible and thereby improve data reliability. The test reactor provides a selectable intensity of up to 1.9 kW m -2 at the photocatalyst surface. The comparability of the results is achieved through the use of pre-calibration and control electronics that minimize the largest sources of uncertainty; most notably variations in the intensity and directionality of the UV light emission of LEDs and in LED device heating.

  10. Adhesion of Photoactive Microalgae to Surfaces is Switchable by Light

    Science.gov (United States)

    Bäumchen, Oliver; Kreis, Christian; Le Blay, Marine; Linne, Christine; Makowski, Marcin

    The natural habitats of many microorganisms are confined geometries, such as the interstitial space of rocks and soil, where interactions with interfaces and surfaces are of paramount importance. We performed in vivo force spectroscopy experiments on the unicellular biflagellated microalga Chlamydomonas, a prime model organism in cell- and microbiology, and discovered that the flagella-mediated adhesion to surfaces can be switched on and off by light. Time-resolved micropipette experiments show that the light-switchable adhesiveness of the flagella is a completely reversible process that is based on a redistribution of adhesion-promoting flagella-membrane proteins within seconds. Light-switchable adhesion enables the cell to regulate the transition between planktonic and surface-associated state, which possibly represents a significant biological advantage for photoactive microorganisms. In terms of the colonization of surfaces and the formation of biofilms, the findings might have immediate economic and environmental relevance in biotechnological settings, such as photo-bioreactors for the sustainable production of biofuels.

  11. X-ray Optics for BES Light Source Facilities

    International Nuclear Information System (INIS)

    Mills, Dennis; Padmore, Howard; Lessner, Eliane

    2013-01-01

    and potentially revolutionary science involves soft excitations such as magnons and phonons; in general, these are well below the resolution that can be probed by today's optical systems. The study of these low-energy excitations will only move forward if advances are made in high-resolution gratings for the soft X-ray energy region, and higher-resolution crystal analyzers for the hard X-ray region. In almost all the forefront areas of X-ray science today, the main limitation is our ability to focus, monochromate, and manipulate X-rays at the level required for these advanced measurements. To address these issues, the U.S. Department of Energy (DOE) Office of Basic Energy Sciences (BES) sponsored a workshop, X-ray Optics for BES Light Source Facilities, which was held March 27-29, 2013, near Washington, D.C. The workshop addressed a wide range of technical and organizational issues. Eleven working groups were formed in advance of the meeting and sought over several months to define the most pressing problems and emerging opportunities and to propose the best routes forward for a focused R&D program to solve these problems. The workshop participants identified eight principal research directions (PRDs), as follows: Development of advanced grating lithography and manufacturing for high-energy resolution techniques such as soft X-ray inelastic scattering. Development of higher-precision mirrors for brightness preservation through the use of advanced metrology in manufacturing, improvements in manufacturing techniques, and in mechanical mounting and cooling. Development of higher-accuracy optical metrology that can be used in manufacturing, verification, and testing of optomechanical systems, as well as at wavelength metrology that can be used for quantification of individual optics and alignment and testing of beamlines. Development of an integrated optical modeling and design framework that is designed and maintained specifically for X-ray optics. Development of

  12. X-ray Optics for BES Light Source Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Dennis [Argonne National Lab. (ANL), Argonne, IL (United States); Padmore, Howard [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lessner, Eliane [Dept. of Energy (DOE), Washington DC (United States). Office of Science

    2013-03-27

    potentially revolutionary science involves soft excitations such as magnons and phonons; in general, these are well below the resolution that can be probed by today’s optical systems. The study of these low-energy excitations will only move forward if advances are made in high-resolution gratings for the soft X-ray energy region, and higher-resolution crystal analyzers for the hard X-ray region. In almost all the forefront areas of X-ray science today, the main limitation is our ability to focus, monochromate, and manipulate X-rays at the level required for these advanced measurements. To address these issues, the U.S. Department of Energy (DOE) Office of Basic Energy Sciences (BES) sponsored a workshop, X-ray Optics for BES Light Source Facilities, which was held March 27–29, 2013, near Washington, D.C. The workshop addressed a wide range of technical and organizational issues. Eleven working groups were formed in advance of the meeting and sought over several months to define the most pressing problems and emerging opportunities and to propose the best routes forward for a focused R&D program to solve these problems. The workshop participants identified eight principal research directions (PRDs), as follows: Development of advanced grating lithography and manufacturing for high-energy resolution techniques such as soft X-ray inelastic scattering. Development of higher-precision mirrors for brightness preservation through the use of advanced metrology in manufacturing, improvements in manufacturing techniques, and in mechanical mounting and cooling. Development of higher-accuracy optical metrology that can be used in manufacturing, verification, and testing of optomechanical systems, as well as at wavelength metrology that can be used for quantification of individual optics and alignment and testing of beamlines. Development of an integrated optical modeling and design framework that is designed and maintained specifically for X-ray optics. Development of

  13. Development of scanning X-ray microscopes for materials science spectromicroscopy at the Advanced Light Source

    International Nuclear Information System (INIS)

    Warwick, T.; Ade, H.

    1997-07-01

    Third generation synchrotron sources of soft x-rays provide an excellent opportunity to apply established x-ray spectroscopic materials analysis techniques to surface imaging on a sub-micron scale. This paper describes an effort underway at the Advanced Light Source (ALS) to pursue this development using Fresnel zone plate lenses. These are used to produce a sub-micron spot of x-rays for use in scanning microscopy. Several groups have developed microscopes using this technique. A specimen is rastered in the focused x-ray spot and a detector signal is acquired as a function of position to generate an image. Spectroscopic capability is added by holding the small spot on a feature of interest and scanning through the spectrum. The authors are pursuing two spectroscopic techniques: Near Edge X-ray Absorption Spectroscopy (NEXAFS), X-ray Photoelectron Spectroscopy (XPS) which together provide a powerful capability for light element analysis in materials science

  14. Surface, interface and bulk materials characterization using Indus synchrotron sources

    International Nuclear Information System (INIS)

    Phase, Deodatta M.

    2014-01-01

    Synchrotron radiation sources, providing intense, polarized and stable beams of ultra violet, soft and hard x-ray photons, are having great impact on physics, chemistry, biology, materials science and other areas research. In particular synchrotron radiation has revolutionized materials characterization techniques by enhancing its capabilities for investigating the structural, electronic and magnetic properties of solids. The availability of synchrotron sources and necessary instrumentation has led to considerable improvements in spectral resolution and intensities. As a result, application scope of different materials characterization techniques has tremendously increased particularly in the analysis of solid surfaces, interfaces and bulk materials. The Indian synchrotron storage ring, Indus-1 and Indus-2 are in operation at RRCAT, Indore. The UGC-DAE CSR with the help of university scientist had designed and developed an angle integrated photoelectron spectroscopy (AlPES) beam line on Indus-1 storage ring of 450 MeV and polarized light beam line for soft x-ray absorption spectroscopy (SXAS) on Indus-2 storage ring of 2.5 GeV. (author)

  15. Networking remote instrumentation for the Advanced Light Source

    International Nuclear Information System (INIS)

    Chin, M.; Hinkson, J.; Magyary, S.

    1989-01-01

    The Advanced Light Source (ALS) control system instrumentation includes high data rate instruments such as digital oscilloscopes, sending 5000-10,000 bytes/s, and low data rate instruments such as network analyzers, digital multimeters and frequency counters sending < 1000 bytes/s. These instruments monitor signals in racks at distances up to 80m from the control room. Remote instrumentation will reduce cabling to the control room and possibly provide for better signal measurement. Inclusion of remote instrumentation data into the machine database will provide flexible access, display, and control from multiple operator workstations. Currently available instrumentation and computers have sufficient performance to provide realtime response in a network configuration. 1 ref., 4 figs

  16. National synchrotron light source medical personnel protection interlock

    International Nuclear Information System (INIS)

    Buda, S.; Gmur, N.F.; Larson, R.; Thomlinson, W.

    1998-01-01

    This report is founded on reports written in April 1987 by Robert Hettel for angiography operations at the Stanford Synchrotron Research Laboratory (SSRL) and a subsequent report covering angiography operations at the National Synchrotron Light Source (NSLS); BNL Informal Report 47681, June 1992. The latter report has now been rewritten in order to accurately reflect the design and installation of a new medical safety system at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). Known originally as the Angiography Personnel Protection Interlock (APPI), this system has been modified to incorporate other medical imaging research programs on the same beamline and thus the name has been changed to the more generic Medical Personnel Protection Interlock (MPPI). This report will deal almost exclusively with the human imaging (angiography, bronchography, mammography) aspects of the safety system, but will briefly explain the modular aspects of the system allowing other medical experiments to be incorporated

  17. The potential and limitations of third generation light sources

    International Nuclear Information System (INIS)

    Hormes, Josef

    2011-01-01

    To date, 3rd generation Light Sources, i.e. electron storage rings where mainly radiation from insertion devices (wigglers and undulators) is used for synchrotron radiation experiments are the 'workhorses' for basic and applied VUV/X-ray research. Several machine parameters. i.e. the energy of the electrons, the emittance and the circumference of the machine, together with the specification of the corresponding insertion devices determine the 'quality' of a facility and a specific beamline. In this talk, several of these aspects are discussed mainly from a users' point of view, i.e. what are the required specifications to carry out 'state-of-the-art' experiments in various areas, e.g. protein crystallography, Resonant Elastic and Inelastic X-ray Scattering (REIXS), Micro-/nanospectroscopy, and time resolved experiments in the femtosecond time domain. (author)

  18. Integrating Gigabit ethernet cameras into EPICS at Diamond light source

    International Nuclear Information System (INIS)

    Cobb, T.

    2012-01-01

    At Diamond Light Source a range of cameras are used to provide images for diagnostic purposes in both the accelerator and photo beamlines. The accelerator and existing beamlines use Point Grey Flea and Flea2 Firewire cameras. We have selected Gigabit Ethernet cameras supporting GigE Vision for our new photon beamlines. GigE Vision is an interface standard for high speed Ethernet cameras which encourages inter-operability between manufacturers. This paper describes the challenges encountered while integrating GigE Vision cameras from a range of vendors into EPICS. GigE Vision cameras appear to be more reliable than the Firewire cameras, and the simple cabling makes much easier to move the cameras to different positions. Upcoming power over Ethernet versions of the cameras will reduce the number of cables still further

  19. Diamond Light Source Booster fast orbit feedback system

    International Nuclear Information System (INIS)

    Gayadeen, S.; Duncan, S.R.; Christou, C.; Heron, M.T.; Rowland, J.

    2012-01-01

    The Fast Orbit Feedback system that has been installed on the Diamond Light Source Storage ring has been replicated on the Booster synchrotron in order to provide a test bed for the development of the Storage Ring controller design. To realise this the Booster is operated in DC mode. The electron beam is regulated in two planes using the Fast Orbit Feedback system, which takes the beam position from 22 beam position monitors for each plane, and calculates offsets to 44 corrector power supplies at a sample rate of 10 kHz. This paper describes the design and realization of the controller for the Booster Fast Orbit Feedback, presents results from the implementation and considers future development

  20. NATIONAL SYNCHROTRON LIGHT SOURCE MEDICAL PERSONNEL PROTECTION INTERLOCK

    Energy Technology Data Exchange (ETDEWEB)

    BUDA,S.; GMUR,N.F.; LARSON,R.; THOMLINSON,W.

    1998-11-03

    This report is founded on reports written in April 1987 by Robert Hettel for angiography operations at the Stanford Synchrotron Research Laboratory (SSRL) and a subsequent report covering angiography operations at the National Synchrotron Light Source (NSLS); BNL Informal Report 47681, June 1992. The latter report has now been rewritten in order to accurately reflect the design and installation of a new medical safety system at the NSLS X17B2 beamline Synchrotron Medical Research Facility (SMERF). Known originally as the Angiography Personnel Protection Interlock (APPI), this system has been modified to incorporate other medical imaging research programs on the same beamline and thus the name has been changed to the more generic Medical Personnel Protection Interlock (MPPI). This report will deal almost exclusively with the human imaging (angiography, bronchography, mammography) aspects of the safety system, but will briefly explain the modular aspects of the system allowing other medical experiments to be incorporated.

  1. A Next Generation Light Source Facility at LBNL

    International Nuclear Information System (INIS)

    Corlett, J.N.; Austin, B.; Baptiste, K.M.; Byrd, J.M.; Denes, P.; Donahue, R.; Doolittle, L.; Falcone, R.W.; Filippetto, D.; Fournier, S.; Li, D.; Padmore, H.A.; Papadopoulos, C.; Pappas, C.; Penn, G.; Placidi, M.; Prestemon, S.; Prosnitz, D.; Qiang, J.; Ratti, A.; Reinsch, M.; Sannibale, F.; Schlueter, R.; Schoenlein, R.W.; Staples, J.W.; Vecchione, T.; Venturini, M.; Wells, R.; Wilcox, R.; Wurtele, J.; Charman, A.; Kur, E.; Zholents, A.A.

    2011-01-01

    The Next Generation Light Source (NGLS) is a design concept, under development at LBNL, for a multibeamline soft x-ray FEL array powered by a ∼2 GeV superconducting linear accelerator, operating with a 1 MHz bunch repetition rate. The CW superconducting linear accelerator is supplied by a high-brightness, high-repetition-rate photocathode electron gun. Electron bunches are distributed from the linac to the array of independently configurable FEL beamlines with nominal bunch rates up to 100 kHz in each FEL, and with even pulse spacing. Individual FELs may be configured for EEHG, HGHG, SASE, or oscillator mode of operation, and will produce high peak and average brightness x-rays with a flexible pulse format, with pulse durations ranging from sub-femtoseconds to hundreds of femtoseconds.

  2. Observations of collective effects at the Advanced Light Source

    International Nuclear Information System (INIS)

    Byrd, J.M.; Barry, W.; Corlett, J.N.; Fox, J.; Teytelman, D.

    1995-10-01

    We present a summary of measurements of single beam collective effects in the Advanced Light Source (ALS). We describe measurements of coupled-bunch instabilities, including some recent results using the newly commissioned feedback systems and the results of an initial search for the fast ion instability. Single bunch effects include bunch lengthening, energy spread increase, HOM loss measurements, head-tail damping rates, current dependent tune shifts, and transverse mode coupling instability threshold. The longitudinal measurements are consistent with a broadband impedance |Ζ parallel /η| eff = 0.22±0.07 Ω and transverse measurements indicate broadband impedances of Ζ y,eff = 155 kΩ/m and Z x,eff = 58 kΩ/m

  3. Single bunch transfer system for the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Sheehan, J.; Singh, O.; Rambo, W.

    1983-01-01

    The accelerator system at the National Synchrotron Light Source consists of an S-band 85 MeV linac and three synchrotron rings. The electron beam from the linac is accelerated by the booster ring to 600 MeV and transferred to one of the two storage rings. The smaller of the two rings operates between 300 and 800 MeV emtting photons in the vacuum ultraviolet (VUV), while the larger storage ring operates up to 2.5 GeV and emits photons in the x-ray spectrum. A system is described for loading the storage rings by filling a single-phase space bunch in the booster ring and transferring it at the end of each booster cycle into a selected bucket in one of the storage rings. By controlling the timing of the transfer on successive transfer cycles, many fill patterns may be obtained

  4. Highlights from e-EPS: Coordinated Access to Light sources

    CERN Multimedia

    e-EPS News

    2014-01-01

    The CALIPSO project, which runs until May 2015, will contribute to the effective exploitation of European synchrotrons and free electron lasers. CALIPSO (Coordinated Access to Light sources to Promote Standards and Optimisation) includes 20 partners forming one of the largest Research Networks in the world.   e-EPS interviewed M. Bertolo, CALIPSO project manager and his assistant C. Blasetti. Which challenges are addressed by CALIPSO? CALIPSO’s goal is to optimize the exploitation of the European synchrotrons and Free Electron Lasers. With respect to previous projects funded by the European Commission, it foresees significant improvements in integration, innovation and user-friendliness in all three areas of networking, transnational access and instrumentation. The Transnational Access program potentially benefits a community of 25,000 estimated users offering free open access to 12 synchrotrons and 5 free electron lasers solely based on scientific merit. In ad...

  5. Insertion device magnet measurements for the Advanced Light Source

    International Nuclear Information System (INIS)

    Marks, S.; Cork, C.; Hoyer, E.; Humphries, D.; Kincaid, B.; Plate, D.; Robb, A.; Schlueter, R.; Wang, C.; Hassenzahl, W.

    1993-05-01

    Allowable magnetic field errors for the 4.6 m long insertion devices for the Advanced Light Source (ALS) are extremely small and are driven by electron beam and radiation requirements. Detailed measurements and adjustments of each insertion device are performed to qualify them for installation in the ALS. To accomplish this, a high speed, precision magnetic measurement facility has been designed and built. Hall probe mapping equipment, capable of completing a 2500 sample, 6 m scan with precision axial position monitoring using a laser interferometer in under one minute, is used to obtain both local and integrated field information. A 5.5 m long, 1 cm wide coil is used to measure the field integral through an entire insertion device. This paper describes magnetic measurement equipment, and results of measurements on IDA, the first of the ALS insertion devices

  6. Linac coherent light source (LCLS) undulator RF BPM system

    International Nuclear Information System (INIS)

    Lill, R.; Waldschmidt, G.; Morrison, L.; Smith, S.; Straumann, T; Li, Z.; Johnson, R.

    2006-01-01

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of the electron beam trajectory on a pulse-to-pulse basis and over many shots. The X-band cavity BPM size, simple fabrication, and high resolution make it an ideal choice for LCLS beam position detection. We will discuss the system specifications, design, and prototype test results.

  7. Linac Coherent Light Source Undulator RF BPM System

    Energy Technology Data Exchange (ETDEWEB)

    Lill, R.M.; Morrison, L.H.; Waldschmidt, G.J.; Walters, D.R.; /Argonne; Johnson, R.; Li, Z.; Smith, S.; Straumann, T.; /SLAC

    2007-04-17

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of the electron beam trajectory on a pulse-to-pulse basis and over many shots. The X-band cavity BPM size, simple fabrication, and high resolution make it an ideal choice for LCLS beam position detection. We will discuss the system specifications, design, and prototype test results.

  8. Linac Coherent Light Source Undulator RF BPM System

    International Nuclear Information System (INIS)

    Lill, R.M.; Morrison, L.H.; Waldschmidt, G.J.; Walters, D.R.; Argonne; Johnson, R.; Li, Z.; Smith, S.; Straumann, T.; SLAC

    2007-01-01

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of the electron beam trajectory on a pulse-to-pulse basis and over many shots. The X-band cavity BPM size, simple fabrication, and high resolution make it an ideal choice for LCLS beam position detection. We will discuss the system specifications, design, and prototype test results

  9. Linac coherent light source (LCLS) undulator RF BPM system.

    Energy Technology Data Exchange (ETDEWEB)

    Lill, R.; Waldschmidt, G.; Morrison, L.; Smith, S.; Straumann, T; Li, Z.; Johnson, R.; SLAC

    2006-01-01

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of the electron beam trajectory on a pulse-to-pulse basis and over many shots. The X-band cavity BPM size, simple fabrication, and high resolution make it an ideal choice for LCLS beam position detection. We will discuss the system specifications, design, and prototype test results.

  10. Beam based feedback for the Linac coherent light source

    International Nuclear Information System (INIS)

    Fairley, D.; Kim, K.; Luchini, K; Natampalli, P.; Piccoli, L.; Rogind, D.; Straumann, T.

    2012-01-01

    Beam-based feedback control loops are required by the Linac Coherent Light Source (LCLS) program in order to provide fast, single-pulse stabilization of beam parameters. Eight transverse feedback loops, a 6*6 longitudinal feedback loop, and a loop to maintain the electron bunch charge have been commissioned on the LCLS, and have been maintaining stability of the LCLS electron beam at beam rates up to 120 Hz. This paper will discuss the design, configuration and commissioning of the beam-based Fast Feedback System for LCLS. Topics include algorithms for 120 Hz feedback, multi-cast network performance, actuator and sensor performance for single-pulse control and sensor read back, and feedback configuration and run-time control. (authors)

  11. Design of the Advanced Light Source timing system

    International Nuclear Information System (INIS)

    Fahmie, M.

    1993-05-01

    The Advanced Light Source (ALS) is a third generation synchrotron radiation facility, and as such, has several unique timing requirements. Arbitrary Storage Ring filling patterns and high single bunch purity requirements demand a highly stable, low jitter timing system with the flexibility to reconfigure on a pulse-to-pulse basis. This modular system utilizes a highly linear Gauss Clock with ''on the fly'' programmable setpoints to track a free-running Booster ramping magnet and provides digitally programmable sequencing and delay for Electron Gun, Linac, Booster Ring, and Storage Ring RF, Pulsed Magnet, and Instrumentation systems. It has proven itself over the last year of accelerator operation to be reliable and rock solid

  12. Complex space source theory of partially coherent light wave.

    Science.gov (United States)

    Seshadri, S R

    2010-07-01

    The complex space source theory is used to derive a general integral expression for the vector potential that generates the extended full Gaussian wave in terms of the input value of the vector potential of the corresponding paraxial beam. The vector potential and the fields are assumed to fluctuate on a time scale that is large compared to the wave period. The Poynting vector in the propagation direction averaged over a wave period is expressed in terms of the cross-spectral density of the fluctuating vector potential across the input plane. The Schell model is assumed for the cross-spectral density. The radiation intensity distribution and the power radiated are determined. The effect of spatial coherence on the radiation intensity distribution and the radiated power are investigated for different values of the physical parameters. Illustrative numerical results are provided to bring out the effect of spatial coherence on the propagation characteristics of the fluctuating light wave.

  13. High-energy scaling of Compton scattering light sources

    Directory of Open Access Journals (Sweden)

    F. V. Hartemann

    2005-10-01

    Full Text Available No monochromatic (Δω_{x}/ω_{x}10^{20}   photons/(mm^{2}×mrad^{2}×s×0.1%   bandwidth], tunable light sources currently exist above 100 keV. Important applications that would benefit from such new hard x-ray and γ-ray sources include the following: nuclear resonance fluorescence spectroscopy and isotopic imaging, time-resolved positron annihilation spectroscopy, and MeV flash radiography. In this paper, the peak brightness of Compton scattering light sources is derived for head-on collisions and found to scale quadratically with the normalized energy, γ; inversely with the electron beam duration, Δτ, and the square of its normalized emittance, ε; and linearly with the bunch charge, eN_{e}, and the number of photons in the laser pulse, N_{γ}:   B[over ^]_{x}∝γ^{2}N_{e}N_{γ}/ε^{2}Δτ. This γ^{2} scaling shows that for low normalized emittance electron beams (1 nC, 1  mm·mrad, 100  MeV, and tabletop laser systems (1–10   J, 5 ps the x-ray peak brightness can exceed 10^{23}   photons/(mm^{2}×mrad^{2}×s×0.1%   bandwidth near ℏω_{x}=1   MeV; this is confirmed by three-dimensional codes that have been benchmarked against Compton scattering experiments performed at Lawrence Livermore National Laboratory. The interaction geometry under consideration is head-on collisions, where the x-ray flash duration is shown to be equal to that of the electron bunch, and which produce the highest peak brightness for compressed electron beams. Important nonlinear effects, including spectral broadening, are also taken into account in our analysis; they show that there is an optimum laser pulse duration in this geometry, of the order of a few picoseconds, in sharp contrast with the initial approach to laser-driven Compton scattering sources where femtosecond laser systems were thought to be mandatory. The analytical expression for the peak on-axis brightness derived here is a powerful tool to

  14. Complex Evaluation of Light Sources in Case of Electric Power Cost Increase

    Directory of Open Access Journals (Sweden)

    Y. N. Kolesnik

    2008-01-01

    Full Text Available The paper gives complex evaluation of efficiency of incandescent lamps, luminescent and light-emitting-diode (LED light sources in case of electric power price increase. On the basis of experimental table lamp electric power indices of light-emitting-diode (LED light sources with equivalent luminous flux have been determined. Dependences of main indices of economic efficiency of various light sources on their operational regimes have been obtained and rate of influence on these indices of electric power price increase have been determined. Economically justified variants and conditions for application of various light sources have been substantiated.

  15. Imaging spectroscopic analysis at the Advanced Light Source

    International Nuclear Information System (INIS)

    MacDowell, A. A.; Warwick, T.; Anders, S.; Lamble, G.M.; Martin, M.C.; McKinney, W.R.; Padmore, H.A.

    1999-01-01

    One of the major advances at the high brightness third generation synchrotrons is the dramatic improvement of imaging capability. There is a large multi-disciplinary effort underway at the ALS to develop imaging X-ray, UV and Infra-red spectroscopic analysis on a spatial scale from. a few microns to 10nm. These developments make use of light that varies in energy from 6meV to 15KeV. Imaging and spectroscopy are finding applications in surface science, bulk materials analysis, semiconductor structures, particulate contaminants, magnetic thin films, biology and environmental science. This article is an overview and status report from the developers of some of these techniques at the ALS. The following table lists all the currently available microscopes at the. ALS. This article will describe some of the microscopes and some of the early applications

  16. Utility and safety of a novel surgical microscope laser light source.

    Science.gov (United States)

    Sato, Taku; Bakhit, Mudathir S; Suzuki, Kyouichi; Sakuma, Jun; Fujii, Masazumi; Murakami, Yuta; Ito, Yuhei; Sugano, Tetsuo; Saito, Kiyoshi

    2018-01-01

    Tissue injuries caused by the thermal effects of xenon light microscopes have previously been reported. Due to this, the development of a safe microscope light source became a necessity. A newly developed laser light source is evaluated regarding its effectiveness and safety as an alternative to conventional xenon light source. We developed and tested a new laser light source for surgical microscopes. Four experiments were conducted to compare xenon and laser lights: 1) visual luminance comparison, 2) luminous and light chromaticity measurements, 3) examination and analysis of visual fatigue, and 4) comparison of focal temperature elevation due to light source illumination using porcine muscle samples. Results revealed that the laser light could be used at a lower illumination value than the xenon light (p source is more efficient and safer than a conventional xenon light source. It lacks harmful ultraviolet waves, has a longer lifespan, a lower focal temperature than that of other light sources, a wide range of brightness and color production, and improved safety for the user's vision. Further clinical trials are necessary to validate the impact of this new light source on the patient's outcome and prognosis.

  17. Status of PEP-X Light Source Design Study

    Energy Technology Data Exchange (ETDEWEB)

    Bane, K.L.F.; Bertsche, K.J.; Cai, Y.; Chao, A.; Huang, X.; Jiao, Y.; Ng, C.-K.; Nosochkov, Y.; Novokhatski, A.; Rivetta, C.H.; Safranek, J.A.; Stupakov, G.V.; Wang, L.; Wang, M.-H.; Xiao, L.; /SLAC; Hettel, R.O.; /SLAC; Rabedeau, T.; /SLAC

    2011-12-14

    The SLAC Beam Physics group and other SLAC collaborators continue to study options for implementing a near diffraction-limited ring-based light source in the 2.2-km PEP-II tunnel that will serve the SSRL scientific program in the future. The study team has completed the baseline design for a 4.5-GeV storage ring having 160 pm-rad emittance with stored beam current of 1.5 A, providing >10{sup 22} brightness for multi-keV photon beams from 3.5-m undulator sources. The team has also investigated possible 5-GeV ERL configurations which, similar to the Cornell and KEK ERL plans, would have {approx}30 pm-rad emittance with 100 mA current, and {approx}10 pm-rad emittance with 25 mA or less. Now a 4.5-GeV 'ultimate' storage ring having emittance similar to the ERL and operating with {approx}200 mA is under study. An overview of the progress of the PEP-X design study and SSRL's plans for defining performance parameters that will guide the choice of ring options is presented.

  18. Perspectives for future light source lattices incorporating yet uncommon magnets

    Directory of Open Access Journals (Sweden)

    S. C. Leemann

    2011-03-01

    Full Text Available Although octupoles, decapoles, and longitudinal gradient bending magnets (LGB have been studied for many years, they are not usually included in light source lattices. They can, however, be beneficial in order to realize ultralow emittance and attain sufficient dynamic aperture. We present methods for achieving ultralow emittance and discuss optimization of the nonlinear dynamics with multipoles. We demonstrate how control of amplitude-dependent tune shift makes octupoles a powerful tool for dynamic aperture optimization. Control of higher-order chromaticity by octupoles and decapoles is straightforward; however, since this turns out to be not quite as efficient in high-brightness lattices with low arc dispersion, we apply it to a conventional lattice to demonstrate the potential. This paper also illustrates how high-field LGBs can be used to build a compact, bright hard x-ray source. Finally, we demonstrate in detail the application of octupoles as integral components of the MAX IV 3 GeV storage ring lattice.

  19. Recycled Thermal Energy from High Power Light Emitting Diode Light Source.

    Science.gov (United States)

    Ji, Jae-Hoon; Jo, GaeHun; Ha, Jae-Geun; Koo, Sang-Mo; Kamiko, Masao; Hong, JunHee; Koh, Jung-Hyuk

    2018-09-01

    In this research, the recycled electrical energy from wasted thermal energy in high power Light Emitting Diode (LED) system will be investigated. The luminous efficiency of lights has been improved in recent years by employing the high power LED system, therefore energy efficiency was improved compared with that of typical lighting sources. To increase energy efficiency of high power LED system further, wasted thermal energy should be re-considered. Therefore, wasted thermal energy was collected and re-used them as electrical energy. The increased electrical efficiency of high power LED devices was accomplished by considering the recycled heat energy, which is wasted thermal energy from the LED. In this work, increased electrical efficiency will be considered and investigated by employing the high power LED system, which has high thermal loss during the operating time. For this research, well designed thermoelement with heat radiation system was employed to enhance the collecting thermal energy from the LED system, and then convert it as recycled electrical energy.

  20. New lasers and light sources - old and new risks?

    Science.gov (United States)

    Paasch, Uwe; Schwandt, Antje; Seeber, Nikolaus; Kautz, Gerd; Grunewald, Sonja; Haedersdal, Merete

    2017-05-01

    Recent developments (new wavelengths, treatment concepts, and combinations) in the field of lasers, intense pulsed light (IPL), LED, as well as new energy and light sources have opened up new therapeutic options that extend beyond mere aesthetic indications. Thus, while fractional lasers used to be employed to merely treat wrinkles, the same devices - in the context of laser-assisted drug delivery - have now become important tools in the treatment of scars, field cancerization, and epithelial tumors. The requirements posed to physicians, both with respect to establishing the indication and conducting treatment, have been growing along with the increase in technological complexity as well as the rising number of comorbidities and comedications in a patient population that continues to age. At the same time, home-use devices have been introduced for a variety of indications. These devices are characterized by low power and special safety features aimed at preventing accidents, risks, and side effects. Despite the reduced efficacy of such self-treatment devices, there is an increased risk of misuse, given that the basic prerequisite for adequate treatment cannot be ensured, to wit, the exact diagnosis and therapeutic indication. Consequently, during hair removal or anti-wrinkle treatment, pigmented lesions and cutaneous neoplasms may be altered, thus giving rise to expected, unexpected and new side effects and complications. In the aforementioned setting, it is important that all potential users of these new technologies be properly trained in a manner that ensures those treated a maximum of safety and efficacy in accordance with the guiding principle "diagnosis certa - ullae therapiae fundamentum". © 2017 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  1. 5 years of ambient pressure photoelectron spectroscopy (APPES) at the Swiss Light Source (SLS)

    Energy Technology Data Exchange (ETDEWEB)

    Olivieri, Giorgia [Laboratory for Surface Science and Technology, Department of Materials, ETH Zürich, CH-8093, Zurich (Switzerland); Giorgi, Javier B. [Department of Chemistry and Biomolecular Sciences, and Centre for Catalysis Research and Innovation, University of Ottawa, Ottawa, Ontario, K1N 6N5 (Canada); Green, Richard G. [Measurement Science and Standards, National Research Council Canada, Ottawa, Ontario K1A 0R6 (Canada); Brown, Matthew A., E-mail: matthew.brown@mat.ethz.ch [Laboratory for Surface Science and Technology, Department of Materials, ETH Zürich, CH-8093, Zurich (Switzerland)

    2017-04-15

    Highlights: • A review of the ongoing research using the APPES endstation of the Swiss Light Source is presented. • Research interests include the liquid-vapor, liquid-nanoparticle and vapor-solid interfaces. • An outlook to the next five years of research at the Swiss Light Source is presented. - Abstract: In March of 2012 an endstation dedicated to ambient pressure photoelectron spectroscopy (APPES) was installed at the Swiss Light Source (SLS) synchrotron radiation facility on the campus of the Paul Scherrer Institute (PSI). The endstation is mobile and operated at the vacuum ultraviolet (VUV), Surfaces/Interfaces: Microscopy (SIM) and Phoenix beamlines, which together afford a nearly continuous photon energy range from 5−8000 eV. This broad energy range is by far the widest available to a single currently operational APPES endstation. During its first five years of operation this endstation has been used to address challenging fundamental problems in the areas of soft-matter colloidal nanoscience, environmental science and energy storage—research that encompasses the liquid-nanoparticle, liquid-vapor (or vacuum) and solid-vapor interfaces. Here we present select highlights of these results and offer an outlook to the next five years of APPES research at the SLS.

  2. Influence of Light Conditions and Light Sources on Clinical Measurement of Natural Teeth Color using VITA Easyshade Advance 4,0®Spectrophotometer. Pilot Study.

    Science.gov (United States)

    Posavec, Ivona; Prpić, Vladimir; Zlatarić, Dubravka Knezović

    2016-12-01

    The purpose of this study was to evaluate and compare lightness (L), chroma (C) and hue (h), green-red (a) and blue-yellow (b) character of the color of maxillary right central incisors in different light conditions and light sources. Two examiners who were well trained in digital color evaluation participated in the research. Intraclass correlation coefficients (ICCs) were used to analyze intra- and interobserver reliability. The LCh and L*a*b* values were determined at 08.15 and at 10.00 in the morning under three different light conditions. Tooth color was assessed in 10 subjects using intraoral spectrophotometer VITA Easyshade Advance 4.0 ® set at the central region of the vestibular surface of the measured tooth. Intra- and interobserver ICC values were high for both examiners and ranged from 0.57 to 0.99. Statistically significant differences in LCh and L*a*b* values measured in different time of the day and certain light condition were not found (p>0.05). Statistically significant differences in LCh and L*a*b* values measured under three different light conditions were not found, too (p>0.05). VITA Easyshade Advance 4.0 ® is reliable enough for daily clinical work in order to assess tooth color during the fabrication of esthtic appliances because it is not dependent on light conditions and light sources.

  3. The Development of the Linac Coherent Light Source RF Gun

    International Nuclear Information System (INIS)

    Dowell, D

    2008-01-01

    The Linac Coherent Light Source (LCLS) is the first x-ray laser user facility based upon a free electron laser (FEL) requiring extraordinary beam quality to saturate at 1.5 angstroms within a 100 meter undulator.[1] This new type of light source is using the last kilometer of the three kilometer linac at SLAC to accelerate the beam to an energy as high as 13.6 GeV and required a new electron gun and injector to produce a very bright beam for acceleration. At the outset of the project it was recognized that existing RF guns had the potential to produce the desired beam but none had demonstrated it. Therefore a new RF gun or at least the modification of an existing gun was necessary. The parameters listed in Table 1 illustrate the unique characteristics of LCLS which drive the requirements for the electron gun as given in Table 2. The gun beam quality needs to accommodate emittance growth as the beam is travels through approximately one kilometer of linac and two bunch compressors before reaching the undulator. These beam requirements were demonstrated during the recent commissioning runs of the LCLS injector and linac [2] due to the successful design, fabrication, testing and operation of the LCLS gun. The goal of this paper is to relate the technical background of how the gun was able to achieve and in some cases exceed these requirements by understanding and correcting the deficiencies of the prototype s-band RF photocathode gun, the BNL/SLAC/UCLA Gun III. This paper begins with a brief history and technical description of Gun III and the Gun Test Facility (GTF) at SLAC, and studies of the gun's RF and emittance compensation solenoid. The work at the GTF identified the gun and solenoid deficiencies, and helped to define the specifications for the LCLS gun. Section 1.1.5 describes the modeling used to compute and correct the gun RF fields and Section 1.1.6 describes the use of these fields in the electron beam simulations. The magnetic design and measurements of

  4. 49 CFR Appendix A to Part 564 - Information To Be Submitted for Replaceable Light Sources

    Science.gov (United States)

    2010-10-01

    ... centerline or filament tolerance box to the bulb base centerline or reference plane. D. For a light source... 49 Transportation 6 2010-10-01 2010-10-01 false Information To Be Submitted for Replaceable Light...) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION REPLACEABLE LIGHT SOURCE...

  5. Paul Scherrer Institute Scientific Report 1998. Volume VII: Swiss Light Source

    International Nuclear Information System (INIS)

    Weyer, Heinz Josef; Bugmann, Marlen; Neuhaus, Sibylle

    1999-01-01

    The Swiss Light Source (SLS) is a medium energy range light source that also provides light with high brilliance in the regime of hard X-rays. It is being constructed at PSI and scheduled to be operational in 2001. A series of new features that were adopted for the design and operation of this machine, is described in this annual report for 1998

  6. Spectral purification and infrared light recycling in extreme ultraviolet lithography sources

    NARCIS (Netherlands)

    Bayraktar, M.; van Goor, F. A.; Boller, K. J.; F. Bijkerk,

    2014-01-01

    We present the design of a novel collector mirror for laser produced plasma (LPP) light sources to be used in extreme ultraviolet (EUV) lithography. The design prevents undesired infrared (IR) drive laser light, reflected from the plasma, from reaching the exit of the light source. This results in a

  7. Detection for flatness of large surface based on structured light

    Science.gov (United States)

    He, Wenyan; Cao, Xuedong; Long, Kuang; Peng, Zhang

    2016-09-01

    In order to get flatness of a large plane, this paper set up a measurement system, composed by Line Structured Light, imaging system, CCD, etc. Line Structured Light transmits parallel fringes at a proper angle onto the plane which is measured; the imaging system and CCD locate above the plane to catch the fringes. When the plane is perfect, CCD will catch straight fringes; however, the real plane is not perfect; according to the theory of projection, the fringes caught by CCD will be distorted by convex and concave. Extract the center of line fringes to obtain the distortion of the fringe, according to the functional relationship between the distortion of fringes and the height which is measured, then we will get flatness of the entire surface. Data from experiment approached the analysis of theory. In the simulation, the vertical resolution is 0.0075 mm per pixel when measuring a plane of 400mm×400mm, choosing the size of CCD 4096×4096, at the angle 85°. Helped by sub-pixel, the precision will get the level of submicron. There are two obvious advantages: method of surface sampling can increase the efficiency for auto-repairing of machines; considering the center of fringe is required mainly in this system, as a consequence, there is no serious demand for back light.

  8. Combining surface plasmonic and light extraction enhancement on InGaN quantum-well light-emitters

    DEFF Research Database (Denmark)

    Fadil, Ahmed; Ou, Yiyu; Iida, Daisuke

    2016-01-01

    and internal quantum efficiency enhancement for InGaN/GaN quantum-well light-emitters. By fabricating dielectric nano-rod pattern on the GaN surface, an optical coating that improves the light extraction is obtained, and furthermore has a low refractive index which blue-shifts the plasmonic resonance of Ag NPs......Surface plasmon coupling with light-emitters and surface nano-patterning have widely been used separately to improve low efficiency InGaN light-emitting diodes. We demonstrate a method where dielectric nano-patterning and Ag nanoparticles (NPs) are combined to provide both light extraction...

  9. Engineering for high heat loads on ALS [Advanced Light Source] beamlines

    International Nuclear Information System (INIS)

    DiGennaro, R.; Swain, T.

    1989-08-01

    This paper discussed general thermal engineering problems and specific categories of thermal design issues for high photon flux beam lines at the LBL Advanced Light Source: thermal distortion of optical surfaces and elevated temperatures of thermal absorbers receiving synchrotron radiation. A generic design for water-cooled heat absorbers is described for use with ALS photon shutters, beam defining apertures, and heat absorbing masks. Also, results of in- situ measurements of thermal distortion of a water-cooled mirror in a synchrotron radiation beam line are compared with calculated performance estimates. 17 refs., 2 figs

  10. SUNY beamline facilities at the National Synchrotron Light Source (Final Report)

    Energy Technology Data Exchange (ETDEWEB)

    Coppens, Philip

    2003-06-22

    The DOE sponsored SUNY synchrotron project has involved close cooperation among faculty at several SUNY campuses. A large number of students and postdoctoral associates have participated in its operation which was centered at the X3 beamline of the National Synchrotron Light Source at Brookhaven National Laboratory. Four stations with capabilities for Small Angle Scattering, Single Crystal and Powder and Surface diffraction and EXAFS were designed and operated with capability to perform experiments at very low as well as elevated temperatures and under high vacuum. A large amount of cutting-edge science was performed at the facility, which in addition provided excellent training for students and postdoctoral scientists in the field.

  11. SUNY beamline facilities at the National Synchrotron Light Source (Final Report)

    International Nuclear Information System (INIS)

    Coppens, Philip

    2003-01-01

    The DOE sponsored SUNY synchrotron project has involved close cooperation among faculty at several SUNY campuses. A large number of students and postdoctoral associates have participated in its operation which was centered at the X3 beamline of the National Synchrotron Light Source at Brookhaven National Laboratory. Four stations with capabilities for Small Angle Scattering, Single Crystal and Powder and Surface diffraction and EXAFS were designed and operated with capability to perform experiments at very low as well as elevated temperatures and under high vacuum. A large amount of cutting-edge science was performed at the facility, which in addition provided excellent training for students and postdoctoral scientists in the field

  12. Linac Coherent Light Source (LCLS) Conceptual Design Report

    Energy Technology Data Exchange (ETDEWEB)

    Nuhn, Heinz-Dieter

    2002-11-25

    The Stanford Linear Accelerator Center, in collaboration with Argonne National Laboratory, Brookhaven National Laboratory, Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, have collaborated to create a conceptual design for a Free-Electron-Laser (FEL) R&D facility operating in the wavelength range 1.5-15 {angstrom}. This FEL, called the ''Linac Coherent Light Source'' (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. The first two-thirds of the SLAC linac are used for injection into the PEP-II storage rings. The last one-third will be converted to a source of electrons for the LCLS. The electrons will be transported to the SLAC Final Focus Test Beam (FFTB) Facility, which will be extended to house a 122-m undulator system. In passing through the undulators, the electrons will be bunched by the force of their own synchrotron radiation to produce an intense, spatially coherent beam of x-rays, tunable in energy from 0.8 keV to 8 keV. The LCLS will include two experiment halls as well as x-ray optics and infrastructure necessary to make use of this x-ray beam for research in a variety of disciplines such as atomic physics, materials science, plasma physics and biosciences. This Conceptual Design Report, the authors believe, confirms the feasibility of constructing an x-ray FEL based on the SLAC linac.

  13. Review of Canadian Light Source facilities for biological applications

    Science.gov (United States)

    Grochulski, Pawel; Fodje, Michel; Labiuk, Shaun; Wysokinski, Tomasz W.; Belev, George; Korbas, Malgorzata; Rosendahl, Scott M.

    2017-11-01

    The newly-created Biological and Life Sciences Department at the Canadian Light Source (CLS) encompasses four sets of beamlines devoted to biological studies ranging in scope from the atomic scale to cells, tissues and whole organisms. The Canadian Macromolecular Crystallography Facility (CMCF) consists of two beamlines devoted primarily to crystallographic studies of proteins and other macromolecules. The Mid-Infrared Spectromicroscopy (Mid-IR) beamline focusses on using infrared energy to obtain biochemical, structural and dynamical information about biological systems. The Bio-Medical Imaging and Therapy (BMIT) facility consists of two beamlines devoted to advanced imaging and X-ray therapy techniques. The Biological X-ray Absorption Spectroscopy (BioXAS) facility is being commissioned and houses three beamlines devoted to X-ray absorption spectroscopy and multi-mode X-ray fluorescence imaging. Together, these beamlines provide CLS Users with a powerful array of techniques to study today's most pressing biological questions. We describe these beamlines along with their current powerful features and envisioned future capabilities.

  14. Handling high data rate detectors at Diamond Light Source

    Science.gov (United States)

    Pedersen, U. K.; Rees, N.; Basham, M.; Ferner, F. J. K.

    2013-03-01

    An increasing number of area detectors, in use at Diamond Light Source, produce high rates of data. In order to capture, store and process this data High Performance Computing (HPC) systems have been implemented. This paper will present the architecture and usage for handling high rate data: detector data capture, large volume storage and parallel processing. The EPICS area Detector frame work has been adopted to abstract the detectors for common tasks including live processing, file format and storage. The chosen data format is HDF5 which provides multidimensional data storage and NeXuS compatibility. The storage system and related computing infrastructure include: a centralised Lustre based parallel file system, a dedicated network and a HPC cluster. A well defined roadmap is in place for the evolution of this to meet demand as the requirements and technology advances. For processing the science data the HPC cluster allow efficient parallel computing, on a mixture of ×86 and GPU processing units. The nature of the Lustre storage system in combination with the parallel HDF5 library allow efficient disk I/O during computation jobs. Software developments, which include utilising optimised parallel file reading for a variety of post processing techniques, are being developed in collaboration as part of the Pan-Data EU Project (www.pan-data.eu). These are particularly applicable to tomographic reconstruction and processing of non crystalline diffraction data.

  15. Linac Coherent Light Source (LCLS) design study report

    International Nuclear Information System (INIS)

    1998-04-01

    The Stanford Linear Accelerator Center (SLAC), in collaboration with Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, is proposing to build a Free-Electron-Laser (FEL) R and D facility operating in the self-amplified spontaneous emission (SASE) mode in the wavelength range 1.5--15 angstrom. This FEL, called Linac Coherent Light Source (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. In this report, the Design Team has established performance parameters for all the major components of the LCLS and developed a layout of the entire system. Chapter 1 is the Executive Summary. Chapter 2 (Overview) provides a brief description of each of the major sections of the LCLS, from the rf photocathode gun, through the experimental stations and electron beam dump. Chapter 3 describes the scientific case for the LCLS. Chapter 4 provides a review of the principles of the FEL physics that the LCLS is based on, and Chapter 5 discusses the choice of the system's physical parameters. Chapters 6 through 10 describe in detail each major element of the system. Chapters 11 through 13 respectively cover undulator controls, mechanical alignment, and radiation issues

  16. Ozone production at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Weilandics, C.; Rohrig, N.; Gmur, N.F.

    1987-01-01

    Ozone production by synchrotron radiation as a function of power density in air was investigated using a white beam at the BNL National Synchrotron Light Source (NSLS) x-ray ring. Power densities were calculated from the energy spectrum at 2.52 GeV. Ozone concentrations in small beam pipes were measured for power densities between I = 10 12 and 10 15 eV . cm -3 . sec -1 . The measured ozone half-life was 37 +- 2 min. The measured G-value was 2.69 +- 0.14 mol/100 eV and the ozone destruction factor k was less than 7 x 10 -19 cm 3 . eV -1 . The random uncertainties stated are approximately one standard error. The large departure of the values for G and k from previous values suggest that some undiscovered systematic error may exist in the experiment. Ozone concentration in excess of the 0.1 ppM ACGIH TLV can be generated in the experimental hutches but can readily be controlled. Industrial hygiene aspects of operation and possible control measures will be discussed. 19 refs., 7 figs., 3 tabs

  17. Linac Coherent Light Source (LCLS) design study report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    The Stanford Linear Accelerator Center (SLAC), in collaboration with Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and the University of California at Los Angeles, is proposing to build a Free-Electron-Laser (FEL) R and D facility operating in the self-amplified spontaneous emission (SASE) mode in the wavelength range 1.5--15 {angstrom}. This FEL, called Linac Coherent Light Source (LCLS), utilizes the SLAC linac and produces sub-picosecond pulses of short wavelength x-rays with very high peak brightness and full transverse coherence. In this report, the Design Team has established performance parameters for all the major components of the LCLS and developed a layout of the entire system. Chapter 1 is the Executive Summary. Chapter 2 (Overview) provides a brief description of each of the major sections of the LCLS, from the rf photocathode gun, through the experimental stations and electron beam dump. Chapter 3 describes the scientific case for the LCLS. Chapter 4 provides a review of the principles of the FEL physics that the LCLS is based on, and Chapter 5 discusses the choice of the system's physical parameters. Chapters 6 through 10 describe in detail each major element of the system. Chapters 11 through 13 respectively cover undulator controls, mechanical alignment, and radiation issues.

  18. Beam-based Feedback for the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Fairley, D.; Allison, S.; Chevtsov, S.; Chu, P.; Decker, F.J.; Emma, P.; Frisch, J.; Himel, T.; Kim, K.; Krejcik, P.; Loos, H.; Lahey, T.; Natampalli, P.; Peng, S.; Rogind, D.; Shoaee, H.; Straumann, T.; Williams, E.; White, G.; Wu, J.; Zelazney, M.; /SLAC

    2010-02-11

    Beam-based feedback control loops are required by the Linac Coherent Light Source (LCLS) program in order to provide fast, single-pulse stabilization of beam parameters. Eight transverse feedback loops, a 6 x 6 longitudinal feedback loop, and a loop to maintain the electron bunch charge were successfully prototyped in MATLAB for the LCLS, and have been maintaining stability of the LCLS electron beam at beam rates up to 30Hz. In the final commissioning phase of LCLS the beam will be operating at up to 120Hz. In order to run the feedback loops at beam rate, the feedback loops will be implemented in EPICS IOCs with a dedicated ethernet multi-cast network. This paper will discuss the design of the beam-based Fast Feedback System for LCLS. Topics include MATLAB feedback prototyping, algorithm for 120Hz feedback, network design for fast data transport, actuator and sensor design for single-pulse control and sensor readback, and feedback configuration and runtime control.

  19. Alternate Tunings for the Linac Coherent Light Source Photoinjector

    CERN Document Server

    Limborg-Deprey, Cecile

    2005-01-01

    The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser (FEL) project based on the SLAC linac. The LCLS Photoinjector beamline has been designed to deliver 10 ps long electron bunches of 1nC with a normalized transverse emittance of less than 1 mm.mrad for 80% of the slices constituting the core of the bunch at 135 MeV. Tolerances and regulation requirements are tight for this tuning. The main contribution to emittance is the "cathode emittance which counts for 0.72 mm.mrad for the nominal tuning. As the "cathode emittance" scales linearly with laser spot radius, the emittance will be dramatically reduced for smaller radius, but this is only possible at lower charge. In particular, for a 0.2nC, we believe we can achieve an emittance closer to 0.4 mm.mrad. This working point will be easier to tune and the beam quality should be much easier to maintain than for the nominal one. In this paper, we also discuss how emittance could be further reduced by using the appropriate laser pulse shaping.

  20. Simplified Daylight Spectrum Approximation by Blending Two Light Emitting Diode Sources

    Science.gov (United States)

    2012-03-01

    highlight both the inefficiencies of existing electric lighting technology and the promises of new, improved lighting alternatives. Electric lamps...all existing electric lighting technology , making LEDs the most efficient and flexible method for producing light from an electric source and will play

  1. Surface measurement errors using commercial scanning white light interferometers

    International Nuclear Information System (INIS)

    Gao, F; Petzing, J; Coupland, J M; Leach, R K

    2008-01-01

    This paper examines the performance of commercial scanning white light interferometers in a range of measurement tasks. A step height artefact is used to investigate the response of the instruments at a discontinuity, while gratings with sinusoidal and rectangular profiles are used to investigate the effects of surface gradient and spatial frequency. Results are compared with measurements made with tapping mode atomic force microscopy and discrepancies are discussed with reference to error mechanisms put forward in the published literature. As expected, it is found that most instruments report errors when used in regions close to a discontinuity or those with a surface gradient that is large compared to the acceptance angle of the objective lens. Amongst other findings, however, we report systematic errors that are observed when the surface gradient is considerably smaller. Although these errors are typically less than the mean wavelength, they are significant compared to the vertical resolution of the instrument and indicate that current scanning white light interferometers should be used with some caution if sub-wavelength accuracy is required

  2. Surface measurement errors using commercial scanning white light interferometers

    Science.gov (United States)

    Gao, F.; Leach, R. K.; Petzing, J.; Coupland, J. M.

    2008-01-01

    This paper examines the performance of commercial scanning white light interferometers in a range of measurement tasks. A step height artefact is used to investigate the response of the instruments at a discontinuity, while gratings with sinusoidal and rectangular profiles are used to investigate the effects of surface gradient and spatial frequency. Results are compared with measurements made with tapping mode atomic force microscopy and discrepancies are discussed with reference to error mechanisms put forward in the published literature. As expected, it is found that most instruments report errors when used in regions close to a discontinuity or those with a surface gradient that is large compared to the acceptance angle of the objective lens. Amongst other findings, however, we report systematic errors that are observed when the surface gradient is considerably smaller. Although these errors are typically less than the mean wavelength, they are significant compared to the vertical resolution of the instrument and indicate that current scanning white light interferometers should be used with some caution if sub-wavelength accuracy is required.

  3. Visible-light system for detecting doxorubicin contamination on skin and surfaces.

    Science.gov (United States)

    Van Raalte, J; Rice, C; Moss, C E

    1990-05-01

    A portable system that uses fluorescence stimulated by visible light to identify doxorubicin contamination on skin and surfaces was studied. When activated by violet-blue light in the 465-nm range, doxorubicin fluoresces, emitting orange-red light in the 580-nm range. The light source to stimulate fluorescence was a slide projector with a filter to selectively pass short-wave (blue) visible light. Fluorescence was both observed visually with viewing spectacles and photographed. Solutions of doxorubicin in sterile 0.9% sodium chloride injection were prepared in nine standard concentrations ranging from 2 to 0.001 mg/mL. Droplets of each admixture were placed on stainless steel, laboratory coat cloth, pieces of latex examination glove, bench-top absorbent padding, and other materials on which antineoplastics might spill or leak. These materials then were stored for up to eight weeks and photographed weekly. The relative ability of water, household bleach, hydrogen peroxide solution, and soap solution to deactivate doxorubicin was also measured. Finally, this system was used to inspect the antineoplastic-drug preparation and administration areas of three outpatient cancer clinics for doxorubicin contamination. Doxorubicin fluorescence was easily detectable with viewing spectacles when a slide projector was used as the light source. The photographic method was sensitive for doxorubicin concentrations from 2.0 to 0.001 mg/mL. Immersion of study materials in bleach for one minute eliminated detectable fluorescence. Doxorubicin contamination is detectable for at least eight weeks in the ambient environment. Probable doxorubicin contamination was detected in two of the three clinics surveyed. A safe, portable system that uses fluorescence stimulated by visible light is a sensitive method for detecting doxorubicin on skin and surfaces.

  4. High Energy Density Science at the Linac Coherent Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, R W

    2007-10-19

    High energy density science (HEDS), as a discipline that has developed in the United States from National Nuclear Security Agency (NNSA)-sponsored laboratory research programs, is, and will remain, a major component of the NNSA science and technology strategy. Its scientific borders are not restricted to NNSA. 'Frontiers in High Energy Density Physics: The X-Games of Contemporary Science' identified numerous exciting scientific opportunities in this field, while pointing to the need for a overarching interagency plan for its evolution. Meanwhile, construction of the first x-ray free-electron laser, the Office-of-Science-funded Linear Coherent Light Source-LCLS: the world's first free electron x-ray laser, with 100-fsec time resolution, tunable x-ray energies, a high rep rate, and a 10 order-of-magnitude increase in brightness over any other x-ray source--led to the realization that the scientific needs of NNSA and the broader scientific community could be well served by an LCLS HEDS endstation employing both short-pulse and high-energy optical lasers. Development of this concept has been well received in the community. NNSA requested a workshop on the applicability of LCLS to its needs. 'High Energy Density Science at the LCLS: NNSA Defense Programs Mission Need' was held in December 2006. The workshop provided strong support for the relevance of the endstation to NNSA strategic requirements. The range of science that was addressed covered a wide swath of the vast HEDS phase space. The unique possibilities provided by the LCLS in areas of intense interest to NNSA Defense Programs were discussed. The areas of focus included warm dense matter and equations of state, hot dense matter, and behavior of high-pressure materials under conditions of high strain-rate and extreme dynamic loading. Development of new and advanced diagnostic techniques was also addressed. This report lays out the relevant science, as brief summaries (Ch. II), expanded

  5. Source signature estimation from multimode surface waves via mode-separated virtual real source method

    Science.gov (United States)

    Gao, Lingli; Pan, Yudi

    2018-02-01

    The correct estimation of the seismic source signature is crucial to exploration geophysics. Based on seismic interferometry, the virtual real source (VRS) method provides a model-independent way for source signature estimation. However, when encountering multimode surface waves, which are commonly seen in the shallow seismic survey, strong spurious events appear in seismic interferometric results. These spurious events introduce errors in the virtual-source recordings, and reduce the accuracy of the source signature estimated by the VRS method. In order to estimate a correct source signature from multimode surface waves, we propose a mode-separated VRS method. In this method, multimode surface waves are mode separated before seismic interferometry. Virtual-source recordings are then obtained by applying seismic interferometry to each mode individually. Therefore, artefacts caused by cross-mode correlation are excluded in the virtual-source recordings and the estimated source signatures. A synthetic example showed that a correct source signature can be estimated with the proposed method, while strong spurious oscillation occurs in the estimated source signature if we do not apply mode separation first. We also applied the proposed method to a field example, which verified its validity and effectiveness in estimating seismic source signature from shallow seismic shot gathers containing multimode surface waves.

  6. Noise analysis of a white-light supercontinuum light source for multiple wavelength confocal laser scanning fluorescence microscopy

    Energy Technology Data Exchange (ETDEWEB)

    McConnell, Gail [Centre for Biophotonics, Strathclyde Institute for Biomedical Sciences, University of Strathclyde, 27 Taylor Street, Glasgow, G4 0NR (United Kingdom)

    2005-08-07

    Intensity correlations of a Ti : sapphire, Kr/Ar and a white-light supercontinuum were performed to quantify the typical signal amplitude fluctuations and hence ascertain the comparative output stability of the white-light supercontinuum source for confocal laser scanning microscopy (CLSM). Intensity correlations across a two-pixel sample (n = 1000) of up to 98%, 95% and 94% were measured for the Ti : sapphire, Kr/Ar and white-light supercontinuum source, respectively. The white-light supercontinuum noise level is therefore acceptable for CLSM, with the added advantage of wider wavelength flexibility over traditional CLSM excitation sources. The relatively low-noise white-light supercontinuum was then used to perform multiple wavelength sequential CLSM of guinea pig detrusor to confirm the reliability of the system and to demonstrate system flexibility.

  7. A new type of white light-emitting diode light source basing on fluorescent SiC

    DEFF Research Database (Denmark)

    Ou, Haiyan; Ou, Yiyu; Lu, Weifang

    Most of the commercial white light-emitting diode (LED) light sources are made from phosphor coated blue-emitting gallium nitride (GaN) chips. This type white LED light source always has tradeoff between luminous efficacy and color rendering index (CRI). Furthermore, yellow-emitting phosphor decays...... much faster than the semiconductor chip, so the white color will turn into bluish over the time. This paper will propose a new type white LED light source: using fluorescent silicon carbide (SiC) to take the place of phosphor. This new type LED has the following advantages: a) SiC is a wide bandgap...... semiconductor material , so it is stable; b) Fluorescent SiC has very wide emission spectrum, and it could generate white light with very high CRI; c) It is a better substrate than sapphire for the GaN growth in terms of lattice match and thermal conductivity. This paper will cover: the growth of fluorescent Si...

  8. Design and evaluation of an imaging spectrophotometer incorporating a uniform light source.

    Science.gov (United States)

    Noble, S D; Brown, R B; Crowe, T G

    2012-03-01

    Accounting for light that is diffusely scattered from a surface is one of the practical challenges in reflectance measurement. Integrating spheres are commonly used for this purpose in point measurements of reflectance and transmittance. This solution is not directly applicable to a spectral imaging application for which diffuse reflectance measurements are desired. In this paper, an imaging spectrophotometer design is presented that employs a uniform light source to provide diffuse illumination. This creates the inverse measurement geometry to the directional illumination/diffuse reflectance mode typically used for point measurements. The final system had a spectral range between 400 and 1000 nm with a 5.2 nm resolution, a field of view of approximately 0.5 m by 0.5 m, and millimeter spatial resolution. Testing results indicate illumination uniformity typically exceeding 95% and reflectance precision better than 1.7%.

  9. heavy metals pollution on surface water sources in kaduna

    African Journals Online (AJOL)

    ABSTRACT. This study examine the effects of heavy metal pollutants to aquatic ecosystems and the environment by considering the role of urban, municipal, agricultural, industrial and other anthropogenic processes as sources of heavy metal pollution in surface water sources of Kaduna metropolis. Samples of the polluted ...

  10. Heavy Metals Pollution on Surface Water Sources in Kaduna ...

    African Journals Online (AJOL)

    This study examine the effects of heavy metal pollutants to aquatic ecosystems and the environment by considering the role of urban, municipal, agricultural, industrial and other anthropogenic processes as sources of heavy metal pollution in surface water sources of Kaduna metropolis. Samples of the polluted water were ...

  11. Salient features in the preparation of gaseous tritium filled luminous light sources

    International Nuclear Information System (INIS)

    Mathew, K.M.; Ravi, S.; Subramanian, T.K.; Ananthakrishnan, M.

    2003-01-01

    Beta radiation emanating from gaseous tritium in close proximity with copper activated zinc sulphide phosphor provides self sustained light sources and these sources are used for nocturnal illumination of liquid crystal display in digital watches and clocks, product advertisements, exit signs etc. We report herein the preparation of low specific radioactivity gaseous tritium (29.5 Ci/m mole; 1.09 TBq/m mole) filled light sources and its effect on light output. (author)

  12. Advanced Light Source activity report 1996/97

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    Ten years ago, the Advanced Light Source (ALS) existed as a set of drawings, calculations, and ideas. Four years ago, it stored an electron beam for the first time. Today, the ALS has moved from those ideas and beginnings to a robust, third-generation synchrotron user facility, with eighteen beam lines in use, many more in planning or construction phases, and hundreds of users from around the world. Progress from concepts to realities is continuous as the scientific program, already strong in many diverse areas, moves in new directions to meet the needs of researchers into the next century. ALS staff members who develop and maintain the infrastructure for this research are similarly unwilling to rest on their laurels. As a result, the quality of the photon beams the authors deliver, as well as the support they provide to users, continues to improve. The ALS Activity Report is designed to share the results of these efforts in an accessible form for a broad audience. The Scientific Program section, while not comprehensive, shares the breadth, variety, and interest of recent research at the ALS. (The Compendium of User Abstracts and Technical Reports provides a more comprehensive and more technical view.) The Facility Report highlights progress in operations, ongoing accelerator research and development, and beamline instrumentation efforts. Although these Activity Report sections are separate, in practice the achievements of staff and users at the ALS are inseparable. User-staff collaboration is essential as they strive to meet the needs of the user community and to continue the ALS's success as a premier research facility.

  13. Advanced Light Source activity report 1996/97

    International Nuclear Information System (INIS)

    1997-01-01

    Ten years ago, the Advanced Light Source (ALS) existed as a set of drawings, calculations, and ideas. Four years ago, it stored an electron beam for the first time. Today, the ALS has moved from those ideas and beginnings to a robust, third-generation synchrotron user facility, with eighteen beam lines in use, many more in planning or construction phases, and hundreds of users from around the world. Progress from concepts to realities is continuous as the scientific program, already strong in many diverse areas, moves in new directions to meet the needs of researchers into the next century. ALS staff members who develop and maintain the infrastructure for this research are similarly unwilling to rest on their laurels. As a result, the quality of the photon beams the authors deliver, as well as the support they provide to users, continues to improve. The ALS Activity Report is designed to share the results of these efforts in an accessible form for a broad audience. The Scientific Program section, while not comprehensive, shares the breadth, variety, and interest of recent research at the ALS. (The Compendium of User Abstracts and Technical Reports provides a more comprehensive and more technical view.) The Facility Report highlights progress in operations, ongoing accelerator research and development, and beamline instrumentation efforts. Although these Activity Report sections are separate, in practice the achievements of staff and users at the ALS are inseparable. User-staff collaboration is essential as they strive to meet the needs of the user community and to continue the ALS's success as a premier research facility

  14. Polymer and small molecule based hybrid light source

    Science.gov (United States)

    Choong, Vi-En; Choulis, Stelios; Krummacher, Benjamin Claus; Mathai, Mathew; So, Franky

    2010-03-16

    An organic electroluminescent device, includes: a substrate; a hole-injecting electrode (anode) coated over the substrate; a hole injection layer coated over the anode; a hole transporting layer coated over the hole injection layer; a polymer based light emitting layer, coated over the hole transporting layer; a small molecule based light emitting layer, thermally evaporated over the polymer based light emitting layer; and an electron-injecting electrode (cathode) deposited over the electroluminescent polymer layer.

  15. National synchrotron light source. Activity report, October 1, 1994--September 30, 1995

    International Nuclear Information System (INIS)

    Rothman, E.Z.; Hastings, J.

    1996-05-01

    This report discusses research conducted at the National Synchrotron Light Source in the following areas: atomic and molecular science; energy dispersive diffraction; lithography, microscopy, and tomography; nuclear physics; scattering and crystallography studies of biological materials; time resolved spectroscopy; UV photoemission and surface science; x-ray absorption spectroscopy; x-ray scattering and crystallography; x-ray topography; the 1995 NSLS annual users' meeting; 17th international free electron laser conference; micro bunches workshop; VUV machine; VUV storage ring parameters; beamline technical improvements; x-ray beamlines; x-ray storage ring parameters; the NSLS source development laboratory; the accelerator test facility (ATF); NSLS facility improvements; NSLS advisory committees; NSLS staff; VUV beamline guide; and x-ray beamline guide

  16. National synchrotron light source. Activity report, October 1, 1994--September 30, 1995

    Energy Technology Data Exchange (ETDEWEB)

    Rothman, E.Z.; Hastings, J. [eds.

    1996-05-01

    This report discusses research conducted at the National Synchrotron Light Source in the following areas: atomic and molecular science; energy dispersive diffraction; lithography, microscopy, and tomography; nuclear physics; scattering and crystallography studies of biological materials; time resolved spectroscopy; UV photoemission and surface science; x-ray absorption spectroscopy; x-ray scattering and crystallography; x-ray topography; the 1995 NSLS annual users` meeting; 17th international free electron laser conference; micro bunches workshop; VUV machine; VUV storage ring parameters; beamline technical improvements; x-ray beamlines; x-ray storage ring parameters; the NSLS source development laboratory; the accelerator test facility (ATF); NSLS facility improvements; NSLS advisory committees; NSLS staff; VUV beamline guide; and x-ray beamline guide.

  17. Multi-channel LED light source for fluorescent agent aided minimally invasive surgery.

    Science.gov (United States)

    Ren, Jiacheng; Venugopalan, Janani; Xu, Jian; Kairdolf, Brad; Durfee, Robert; Wang, May D

    2014-01-01

    Cancer is one of the most common and deadly diseases around the world. Amongst all the different treatments of cancer such as surgery, chemotherapy and radiation therapy, surgical resection is the most effective. Successful surgeries greatly rely on the detection of the accurate tumor size and location, which can be enhanced by contrast agents. Commercial endoscope light sources, however, offer only white light illumination. In this paper, we present the development of a LED endoscope light source that provides 2 light channels plus white light to help surgeons to detect a clear tumor margin during minimally invasive surgeries. By exciting indocyanine green (ICG) and 5-Aminolaevulinic acid (ALA)-induced protoporphyrin IX (PPIX), the light source is intended to give the user a visible image of the tumor margin. This light source is also portable, easy to use and costs less than $300 to build.

  18. Influence of Light Emitting Diode-Derived Blue Light Overexposure on Mouse Ocular Surface.

    Science.gov (United States)

    Lee, Hyo Seok; Cui, Lian; Li, Ying; Choi, Ji Suk; Choi, Joo-Hee; Li, Zhengri; Kim, Ga Eon; Choi, Won; Yoon, Kyung Chul

    2016-01-01

    To investigate the influence of overexposure to light emitting diode (LED)-derived light with various wavelengths on mouse ocular surface. LEDs with various wavelengths were used to irradiate C57BL/6 mice at an energy dose of 50 J/cm2, twice a day, for 10 consecutive days. The red, green, and blue groups represented wavelengths of 630 nm, 525 nm, and 410 nm, respectively. The untouched group (UT) was not exposed to LED light and served as the untreated control. Tear volume, tear film break-up time (TBUT), and corneal fluorescein staining scores were measured on days 1, 3, 5, 7, and 10. Levels of interferon (IFN)-γ, interleukin (IL)-1β, IL-6, and tumor necrosis factor (TNF)-α were measured in the cornea and conjunctiva using a multiplex immunobead assay at day 10. Levels of malondialdehyde (MDA) were measured with an enzyme-linked immunosorbent assay. Flow cytometry, 2'7'-dichlorofluorescein diacetate (DCF-DA) assay, histologic analysis, immunohistochemistry with 4-hydroxynonenal, and terminal deoxynucleotidyl transferase-mediated dUTP-nick end labeling (TUNEL) staining were also performed. TBUT of the blue group showed significant decreases at days 7 and 10, compared with the UT and red groups. Corneal fluorescein staining scores significantly increased in the blue group when compared with UT, red, and green groups at days 5, 7, and 10. A significant increase in the corneal levels of IL-1β and IL-6 was observed in the blue group, compared with the other groups. The blue group showed significantly increased reactive oxygen species production in the DCF-DA assay and increased inflammatory T cells in the flow cytometry. A significantly increased TUNEL positive cells was identified in the blue group. Overexposure to blue light with short wavelengths can induce oxidative damage and apoptosis to the cornea, which may manifest as increased ocular surface inflammation and resultant dry eye.

  19. EDITORIAL: Extreme Ultraviolet Light Sources for Semiconductor Manufacturing

    Science.gov (United States)

    Attwood, David

    2004-12-01

    issue of available EUV power from electrical discharge pinch plasmas and laser produced plasmas, including the roots of these requirements, the relevant plasma and radiation physics, and current state-of-the-art commercial technology. In the first paper of the cluster, Vadim Banine and Roel Moors of ASML in the Netherlands provide a detailed review of the required EUV power based on an economically viable throughput of one hundred 300 mm diameter wafers per hour, projected resist sensitivity, number of finite reflectivity multilayer coated surfaces and their collective spectral bandwidth, and a collection solid angle set by optical phase-space constraints and plasma source size. Thomas Krücken and his colleagues from Philips and the Fraunhofer Institute in Aachen present a theoretical model of radiation generation and transport based on model density and temperature profiles in an electrical discharge plasma, providing valuable insights into radiation physics and the limits to achievable power. Kenneth Fahy and his colleagues at UCD in Dublin and NIST in the US, in their paper, describe in detail atomic physics calculations of emission from relevant lines and unresolved transition arrays (UTAs) of candidate xenon and tin ions, each of which radiate strongly within the acceptance bandwidth of the multilayer coatings. The different elements, Xe and Sn, however, raise significantly different implications for source debris production and thus of requisite debris mitigation requirements. Björn Hannson and Hans Hertz of KTH University in Stockholm present a substantial review of laser produced plasmas for the EUV, including those based on liquid jet technologies, leading to a path of mass limited target material, and significant stand-off distance from the solid nozzle, which maximize EUV power generation while minimizing debris production. In addition to an extensive review of EUV source related literature, they describe experiments with laser irradiated droplets and

  20. Current-voltage model of LED light sources

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2012-01-01

    Amplitude modulation is rarely used for dimming light-emitting diodes in polychromatic luminaires due to big color shifts caused by varying magnitude of LED driving current and nonlinear relationship between intensity of a diode and driving current. Current-voltage empirical model of light...

  1. 2-10 μm Mid-infrared Supercontinuum Light Sources

    DEFF Research Database (Denmark)

    Petersen, Christian Rosenberg; Møller, Uffe Visbech

    Spectroscopy is the study of how light interacts with molecules, which can be used to identify various substances in for example foods and medicine, by observing which parts of the light is absorbed after interaction with the sample. Especially infrared light, more precisely the mid infrared part...... of the spectrum, is of interest because almost all molecules display distinct absorption fingerprints in this region. Current instrumentation however relies on thermal light sources, much like the wellknown incandescent light bulb, which has very limited brightness and limited possibilities for manipulating...... and using the light in different applications. This dissertation presents the past three years of my work with developing an alternative light source that has the broad spectral bandwidth of a lamp, and high power focused in a tight spot similar to a laser. Such a mid‐infrared light source can be achieved...

  2. LED surgical lighting system with multiple free-form surfaces for highly sterile operating theater application.

    Science.gov (United States)

    Liu, Peng; Zhang, Yaqin; Zheng, Zhenrong; Li, Haifeng; Liu, Xu

    2014-06-01

    Although the ventilation system is widely employed in the operating theater, a strictly sterile surgical environment still cannot be ensured because of laminar disturbance, which is mainly caused by the surgical lighting system. Abandoning traditional products, we propose an LED surgical lighting system, which can alleviate the laminar disturbance and provide an appropriate lighting condition for surgery. It contains a certain amount of LED lens units, which are embedded in the ceiling and arranged around the air supply smallpox. The LED lens unit integrated with an LED light source and a free-form lens is required to produce a uniform circular illumination with a large tolerance to the change of lighting distance. To achieve such a dedicated lens, two free-form refractive surfaces, which are converted into two ordinary differential equations by the design method presented in this paper, are used to deflect the rays. The results show that the LED surgical lighting system can provide an excellent illumination environment for surgery, and, apparently, the laminar disturbance also can be relieved.

  3. Combined effects of blue light and supplemental far-red light and effects of increasing red light with constant far-red light on growth of kidney bean [Phaseolus vulgaris] under mixtures of narrow-band light sources

    International Nuclear Information System (INIS)

    Hanyu, H.; Shoji, K.

    2000-01-01

    Increasing blue light and decreasing R: FR with supplementary far-red light affect morphogenesis, dry matter production and dry matter partitioning to leaves, stems and roots. In this study, the combined effects of the two spectral treatments were examined in kidney bean (Phaseolus vulgaris L.) grown under the mixture of four different narrow-band light sources. In addition, because the leaf and stem growth are accelerated by increasing red light (600-700 nm) in proportion to far-red light (700-800 nm) while keeping R : FR constant, this study was conducted to determine whether red light or far-red light causes the acceleration of growth. Increasing blue light (400-500 nm) and decreasing R : FR only interacted on stem extension. The results illustrated with figures suggest that blue light amplifies or attenuates the acceleration of stem extension caused by decreasing R : FR. On the other hand, increasing red light with constant far-red light had no influence on leaf expansion or stem extension while R : FR increased. Because the acceleration of leaf and stem growth is caused by increasing either far-red light or both red and far-red light in our environmental conditions, the stimulative effects on leaves and stems seem to require increases in far-red light rather than red light

  4. SESAME — A 3rd Generation Synchrotron Light Source for the Middle East

    Science.gov (United States)

    Å°lkü, Dinçer; Rahighi, Javad; Winick, Herman

    2007-01-01

    SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) will be the Middle East's first international research center. It is a cooperative venture by the scientists and governments of the region with founding members Bahrain, Egypt, Israel, Jordan, Pakistan, Palestine Authority, and Turkey. Iran is in the process of finalizing its formal membership. Other countries (Cyprus, Morocco, and the United Arab Emirates) are also expected to join. The permanent Council of member states has full responsibility for the project. Members provide the annual operating budget. Observer countries are Germany, Greece, Italy, Kuwait, Portugal, Russian Federation, Sweden, the UK, and the US. SESAME is being developed under the umbrella of UNESCO. Jordan was selected as the building site. SESAME will offer excellent opportunities for training of Middle East scientists and attract those working abroad to consider returning. SESAME will be a 2.5GeV 3rd Generation light source (emittance 26nm-rad, circumference ˜133m), providing excellent performance for structural molecular biology, molecular environmental science, surface and interface science, microelectromechanical devices, x-ray imaging, archaeological microanalysis, and materials characterization. It will cover a broad spectral range from the infrared to hard x-rays and will have 12 straight sections for insertion devices (average length 2.75m). The injector will be the BESSY I 0.8 GeV booster synchrotron which has been given as a gift from Germany. Four committees advise the Council and assist in developing the technical design, beam lines, user community, and scientific Program. The SESAME building, now in construction with funds and a site provided by Jordan, is scheduled for completion in late 2006 after which the BESSY I injector will be installed. First stored beam in the new 2.5 GeV ring is planned for 2009 with six initial beamlines planned. Some beamlines will be built by member countries

  5. SESAME - A 3rd Generation Synchrotron Light Source for the Middle East

    International Nuclear Information System (INIS)

    Ulkue, Dincer; Rahighi, Javad; Winick, Herman

    2007-01-01

    SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) will be the Middle East's first international research center. It is a cooperative venture by the scientists and governments of the region with founding members Bahrain, Egypt, Israel, Jordan, Pakistan, Palestine Authority, and Turkey. Iran is in the process of finalizing its formal membership. Other countries (Cyprus, Morocco, and the United Arab Emirates) are also expected to join. The permanent Council of member states has full responsibility for the project. Members provide the annual operating budget. Observer countries are Germany, Greece, Italy, Kuwait, Portugal, Russian Federation, Sweden, the UK, and the US. SESAME is being developed under the umbrella of UNESCO. Jordan was selected as the building site. SESAME will offer excellent opportunities for training of Middle East scientists and attract those working abroad to consider returning. SESAME will be a 2.5GeV 3rd Generation light source (emittance 26nm-rad, circumference ∼133m), providing excellent performance for structural molecular biology, molecular environmental science, surface and interface science, microelectromechanical devices, x-ray imaging, archaeological microanalysis, and materials characterization. It will cover a broad spectral range from the infrared to hard x-rays and will have 12 straight sections for insertion devices (average length 2.75m). The injector will be the BESSY I 0.8 GeV booster synchrotron which has been given as a gift from Germany. Four committees advise the Council and assist in developing the technical design, beam lines, user community, and scientific Program. The SESAME building, now in construction with funds and a site provided by Jordan, is scheduled for completion in late 2006 after which the BESSY I injector will be installed. First stored beam in the new 2.5 GeV ring is planned for 2009 with six initial beamlines planned. Some beamlines will be built by member countries

  6. SESAME - A 3rd Generation Synchrotron Light Source for the Middle East

    Science.gov (United States)

    U˝Lkü, Dinçer; Rahighi, Javad; Winick, Herman

    2007-01-01

    SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) will be the Middle East's first international research center. It is a cooperative venture by the scientists and governments of the region with founding members Bahrain, Egypt, Israel, Jordan, Pakistan, Palestine Authority, and Turkey. Iran is in the process of finalizing its formal membership. Other countries (Cyprus, Morocco, and the United Arab Emirates) are also expected to join. The permanent Council of member states has full responsibility for the project. Members provide the annual operating budget. Observer countries are Germany, Greece, Italy, Kuwait, Portugal, Russian Federation, Sweden, the UK, and the US. SESAME is being developed under the umbrella of UNESCO. Jordan was selected as the building site. SESAME will offer excellent opportunities for training of Middle East scientists and attract those working abroad to consider returning. SESAME will be a 2.5GeV 3rd Generation light source (emittance 26nm-rad, circumference ~133m), providing excellent performance for structural molecular biology, molecular environmental science, surface and interface science, microelectromechanical devices, x-ray imaging, archaeological microanalysis, and materials characterization. It will cover a broad spectral range from the infrared to hard x-rays and will have 12 straight sections for insertion devices (average length 2.75m). The injector will be the BESSY I 0.8 GeV booster synchrotron which has been given as a gift from Germany. Four committees advise the Council and assist in developing the technical design, beam lines, user community, and scientific Program. The SESAME building, now in construction with funds and a site provided by Jordan, is scheduled for completion in late 2006 after which the BESSY I injector will be installed. First stored beam in the new 2.5 GeV ring is planned for 2009 with six initial beamlines planned. Some beamlines will be built by member countries

  7. Ultraviolet light and heat source selection in captive spiny-tailed iguanas (Oplurus cuvieri)

    International Nuclear Information System (INIS)

    Dickinson, H.C.; Fa, J.E.

    1997-01-01

    Three experimental manipulations were conducted to assess the influence of heat source selection and active thermoregulation on ultraviolet (UV) light exposure in captive spiny-tailed iguanas (Oplurus cuvieri) at the Jersey Wildlife Preservation Trust. Four replicates per manipulation were conducted on six individual lizards. All animals were tested in a separate enclosure to which they were acclimated before observations. Data on choice of thermal sources were collected during the first 2 hr of light, when lizards were actively thermoregulating. Animals were allowed to choose between incandescent light, UV light and a non-light heat source (thermotube) in different combinations. Recorded temperatures close to the incandescent light (37°C) were always significantly higher than at the thermotube (33°C) and at the UV light (29°C). Manipulation 1 offered the animals a choice of an UV light and an incandescent light as thermal sources. Manipulation 2 presented animals with the thermal choices in Manipulation 1, but substrates under each source in Manipulation 1 were switched. In Manipulation 3, animals could choose between an incandescent light and the thermotube. All studied lizards were significantly more attracted to the incandescent light than to the UV light or thermotube. Incandescent light elicited a significantly higher proportion of basking behaviors in all individuals than the other sources. A high proportion of time basking was also spent in front of the thermotube but fewer individuals and less time were spent basking under the UV light. Heat source selection was generally found to be independent of substrate. Management applications of this preference are suggested for juvenile diurnal heliothermic iguanids. (author)

  8. Potential sustainable energy source: Pheroid™ with incorporated light harvesting materials

    CSIR Research Space (South Africa)

    Smit, Jacoba E

    2010-09-01

    Full Text Available The most efficient light harvesting and energy transfer systems are found in nature as part of the photosynthesis process. By extracting these system fragments and maximising their organisational structure, researchers are developing similar...

  9. Application of Surface Plasmonics for Semiconductor Light-Emitting Diodes

    DEFF Research Database (Denmark)

    Fadil, Ahmed

    . By placing metallic thin films or nanoparticles (NPs) in the near-field of QW light-emitters, it is possible to improve their internal quantum efficiency (IQE) through the Purcell enhancement effect. It has been a general understanding that in order to achieve surface plasmon (SP) coupling with QWs......-QW coupling does not necessarily lead to emission enhancement. The findings of this work show that the scattering and absorption properties of NPs play a crucial role in determining whether the implementation will improve or degrade the optical performance. By applying these principles, a novel design...... methods are presented to improve the efficiency of the QWs. Furthermore, a design for electrically driven LED device with SP compatibility is proposed, and requirements on p-type GaN layer thickness and current spreading properties are investigated experimentally....

  10. Source attribution of light-absorbing impurities in seasonal snow across northern China

    Science.gov (United States)

    Zhang, R.; Hegg, D. A.; Huang, J.; Fu, Q.

    2013-01-01

    Seasonal snow samples obtained at 46 sites in 6 provinces of China in January and February 2010 were analyzed for a suite of chemical species and these data are combined with previously determined concentrations of light-absorbing impurities (LAI), including all particles that absorb light in the 650-700 nm wavelength interval. The LAI, together with 14 other analytes, are used as input to a positive matrix factorization (PMF) receptor model to explore the sources of the LAI in the snow. The PMF analysis for the LAI sources is augmented with backward trajectory cluster analysis and the geographic locations of major source areas for the three source types. The two analyses are consistent and indicate that three factors/sources were responsible for the measured snow light absorption: a soil dust source, an industrial pollution source, and a biomass and biofuels burning source. Soil dust was the main source of the LAI, accounting for ~ 53% of the LAI on average.

  11. Source attribution of insoluble light-absorbing particles in seasonal snow across northern China

    Science.gov (United States)

    Zhang, R.; Hegg, D. A.; Huang, J.; Fu, Q.

    2013-06-01

    Seasonal snow samples obtained at 46 sites in 6 provinces of China in January and February 2010 were analyzed for a suite of chemical species and these data are combined with previously determined concentrations of insoluble light-absorbing particles (ILAP), including all particles that absorb light in the 650-700 nm wavelength interval. The ILAP, together with 14 other analytes, are used as input to a positive matrix factorization (PMF) receptor model to explore the sources of ILAP in the snow. The PMF analysis for ILAP sources is augmented with backward trajectory cluster analysis and the geographic locations of major source areas for the three source types. The two analyses are consistent and indicate that three factors/sources were responsible for the measured light absorption of snow: a soil dust source, an industrial pollution source, and a biomass and / or biofuel burning source. Soil dust was the main source of the ILAP, accounting for ~53% of ILAP on average.

  12. Investigation of a scanning laser projector as an energy-efficient light source in plant production

    NARCIS (Netherlands)

    Murase, Haruhiko; Helm, van der Bob; Oke, Satoshi

    2015-01-01

    The energy costs for artificial lighting in plant factories are very high, but may be decreased by introducing more efficient light sources. Light absorption in plants takes place in the order of a femtosecond, while the chemical reactions for carbon fixation of 5 milliseconds are limiting the

  13. Surface-source modeling and estimation using biomagnetic measurements.

    Science.gov (United States)

    Yetik, Imam Samil; Nehorai, Arye; Muravchik, Carlos H; Haueisen, Jens; Eiselt, Michael

    2006-10-01

    We propose a number of electric source models that are spatially distributed on an unknown surface for biomagnetism. These can be useful to model, e.g., patches of electrical activity on the cortex. We use a realistic head (or another organ) model and discuss the special case of a spherical head model with radial sensors resulting in more efficient computations of the estimates for magnetoencephalography. We derive forward solutions, maximum likelihood (ML) estimates, and Cramér-Rao bound (CRB) expressions for the unknown source parameters. A model selection method is applied to decide on the most appropriate model. We also present numerical examples to compare the performances and computational costs of the different models and illustrate when it is possible to distinguish between surface and focal sources or line sources. Finally, we apply our methods to real biomagnetic data of phantom human torso and demonstrate the applicability of them.

  14. lightsources.org: An Internet Site for Light SourceCommunication

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Art

    2004-10-04

    Research at the world's accelerator- (storage-ring and linac) based light sources is one of the most dynamic and rapidly growing fields of science. It frequently results in direct benefits to society, thereby demonstrating the value of the research with very concrete examples, but this is not widely understood or appreciated outside of the immediate user community. Our growing group of light source communicators from facilities in Europe, Asia, and the Americas, inspired by the Interactions.org Web site created by high-energy (elementary-particle)physics communicators, concluded that a light source community Web site (lightsources.org) would be the best tool for establishing effective collaboration between the communications offices of the world's light sources and to maximize the impact of our efforts. We envision lightsources.org to serve as a one-stop-shopping site for information about all aspects of light sources and the research they make possible. Audiences to be served include science communicators, the press, policymakers, the light source community, the wider scientific community, the science-interested public, and students and educators. Our proposal has been sent to the world's light source facility directors by J. Murray Gibson (APS) and William G. Stirling (ESRF). As a result,light sources.org is now being supported by a growing list of facilities from Europe, North America, and Asia. We hope to launch lightsources.org before the end of 2004.

  15. Spectra Analysis in Sunset Color Demonstrations with a White-Color LED as a Light Source

    OpenAIRE

    Makoto Hasegawa; Seika Tokumitsu

    2016-01-01

    Spectra of light beams emitted from white-color LED torches are different from those of conventional electric torches. In order to confirm if white-color LED torches can be used as light sources for popular sunset color demonstrations in spite of such differences, spectra of travelled light beams and scattered light beams with each of a white-color LED torch (composed of a blue LED and yellow-color fluorescent material) and a conventional electric torch as a light source were measured and com...

  16. Rapid Automatic Lighting Control of a Mixed Light Source for Image Acquisition using Derivative Optimum Search Methods

    Directory of Open Access Journals (Sweden)

    Kim HyungTae

    2015-01-01

    Full Text Available Automatic lighting (auto-lighting is a function that maximizes the image quality of a vision inspection system by adjusting the light intensity and color.In most inspection systems, a single color light source is used, and an equal step search is employed to determine the maximum image quality. However, when a mixed light source is used, the number of iterations becomes large, and therefore, a rapid search method must be applied to reduce their number. Derivative optimum search methods follow the tangential direction of a function and are usually faster than other methods. In this study, multi-dimensional forms of derivative optimum search methods are applied to obtain the maximum image quality considering a mixed-light source. The auto-lighting algorithms were derived from the steepest descent and conjugate gradient methods, which have N-size inputs of driving voltage and one output of image quality. Experiments in which the proposed algorithm was applied to semiconductor patterns showed that a reduced number of iterations is required to determine the locally maximized image quality.

  17. Light transmittance of 1-piece hydrophobic acrylic intraocular lenses with surface light scattering removed from cadaver eyes.

    Science.gov (United States)

    Werner, Liliana; Morris, Caleb; Liu, Erica; Stallings, Shannon; Floyd, Anne; Ollerton, Andrew; Leishman, Lisa; Bodnar, Zachary

    2014-01-01

    To assess the potential effect of surface light scattering on light transmittance of 1-piece hydrophobic acrylic intraocular lenses (IOLs) with or without a blue-light filter. John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Experimental study. Intraocular lenses were obtained from human cadavers (49 IOLs total; 36 with blue-light filter) and from finished-goods inventory (controls). The IOLs were removed from cadaver eyes and the power and model matched to unused controls. After surface proteins were removed, the IOLs were hydrated for 24 hours at room temperature. Surface light scattering was measured with a Scheimpflug camera (EAS-1000 Anterior Segment Analysis System). Light transmittance was measured with a Lambda 35 UV/Vis spectrophotometer (single-beam configuration; RSA-PE-20 integrating sphere). Hydrated scatter values ranged from 4.8 to 202.5 computer-compatible tape (CCT) units for explanted IOLs with blue-light filter and 1.5 to 11.8 CCT units for controls; values ranged from 6.0 to 137.5 CCT units for explanted IOLs without a blue-light filter and 3.5 to 9.6 CCT units for controls. In both groups, there was a tendency toward increasing scatter values with increasing postoperative time. No differences in light transmittance were observed between explanted IOLs and controls in both groups (IOLs with blue-light filter: P=.407; IOL with no blue-light filter: P=.487; both paired t test). Although surface light scattering of explanted IOLs was significantly higher than that of controls and appeared to increase with time, no effect was observed on light transmittance of 1-piece hydrophobic acrylic IOLs with or without a blue-light filter. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Classification of radioactive self-luminous light sources. American national standard

    International Nuclear Information System (INIS)

    1976-01-01

    This standard establishes the classification of certain radioactive self-luminous light sources according to radionuclide, type of source, activity, and performance requirements. The objectives are to establish minimum prototype testing requirements for radioactive self-luminous light sources, to promote uniformity of marking such sources, and to establish minimum physical performance for such sources. This standard is primarily directed toward assuring adequate containment of the radioactive material. Testing procedures and classification designations are specified for discoloration, temperature, thermal shock, reduced pressure, impact, vibration, and immersion. A range of test requirements is presented according to intended usage and source activity

  19. SUNY beam line X3, National Synchrotron Light Source

    International Nuclear Information System (INIS)

    1991-01-01

    This report discusses: beamline change and upgrades at NSLS; crystallography; surface structure; small angle scattering; EXAFS, glazing angle and fluorescence studies; and high temperature superconductors. (LSP)

  20. SUNY beam line X3, National Synchrotron Light Source

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-01

    This report discusses: beamline change and upgrades at NSLS; crystallography; surface structure; small angle scattering; EXAFS, glazing angle and fluorescence studies; and high temperature superconductors. (LSP).

  1. [SUNY beamline facilities at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Coppens, P.

    1992-01-01

    This report contains short discussions on the following topics which mainly deal with superconductors: crystallography; surface structure; scattering and EXAFS studies; small angle scattering of x-rays

  2. SUNY beamline facilities at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Coppens, P.

    1993-01-01

    This document presents information concerning: crystallography (single crystal studies); crystallography (powder diffraction); crystallography (surface structure); exafs and interface studies; and small angle scattering

  3. Investigating the Effect of Different Light Sources on the Microtensile Bond Strength of Two Types of Adhesives to Dentin

    Directory of Open Access Journals (Sweden)

    M Momeni Sarvestani

    2013-08-01

    Full Text Available Introduction: Different light sources influence restoration bond strength. Therefore the purpose of this study was evaluation of the microtensile bond strength of two types of sixth generation adhesives in different light sources. Methods: some sound human molars were collected. 10 sample in each group was prepared that totally 60 samples were investigated. In each tooth some dentinal specimen was prepared in buccal surface using diamond bur after abrading the enamel. Composite resin (Z250 was inserted in form of a layer using a Clearfil SE bond and Adper prompt L-POP adhesives. Both adhesives were polymerized using different light curing units including QTH at 600mW/cm2, LED at 400mW/cm2, PAC at1200mW/cm2, G1-Adper /LED, G2-Adper /Plasma, G3-Adper /QTH, G4-SE/LED, G5-SE /Plasma, G6-SE /QTH. The restorations were sectioned with 1mm thickness per teeth. All specimens were then subjected to microtensile testing machines. Then, data were analyzed using SPSS software, ANOVA and T-test. Results: Clearfil SE /Plasma arc group had the highest bond strength. The bond strength of Adper prompt L-POP significantly varied in different light sources (p<0.05. Significant difference was observed between Adper and SE (p<0.05 while using LED. Conclusion: This study showed that various light sources have different influence on bond strength.

  4. Study on the Light Scattering from Random Rough Surfaces by Kirrhoff Approximation

    Directory of Open Access Journals (Sweden)

    Keding Yan

    2014-07-01

    Full Text Available In order to study the space distribution characteristics of light scattering from random rough surfaces, the linear filtering method is used to generate a series of Gaussian randomly rough surfaces, and the Kirchhoff Approximation is used to calculate the scattered light intensity distribution from random metal and dielectric rough surfaces. The three characteristics of the scattered light intensity distribution peak, the intensity distribution width and the position of peak are reviewed. Numerical calculation results show that significant differences between scattering characteristics of metal surfaces and the dielectric surfaces exist. The light scattering characteristics are jointly influenced by the slope distribution and reflectance of surface element. The scattered light intensity distribution is affected by common influence of surface local slope distribution and surface local reflectivity. The results can provide a basis theory for the research to lidar target surface scattering characteristics.

  5. Lasers or light sources for treating port-wine stains

    DEFF Research Database (Denmark)

    Faurschou, Annesofie; Olesen, Anne Braae; Leonardi-Bee, Jo

    2011-01-01

    Port-wine stains are birthmarks caused by malformations of blood vessels in the skin. Port-wine stains manifest themselves in infancy as a flat, red mark and do not regress spontaneously but may, if untreated, become darker and thicker in adult life. The profusion of various lasers and light...

  6. Surface Coating of Plastic Parts for Business Machines (Industrial Surface Coating): New Source Performance Standards (NSPS)

    Science.gov (United States)

    Learn more about the new source performance standards (NSPS) for surface coating of plastic parts for business machines by reading the rule summary and history and finding the code of federal regulations as well as related rules.

  7. The influence of lithology on surface water sources | Science ...

    Science.gov (United States)

    Understanding the temporal and spatial variability of surface water sources within a basin is vital to our ability to manage the impacts of climate variability and land cover change. Water stable isotopes can be used as a tool to determine geographic and seasonal sources of water at the basin scale. Previous studies in the Coastal Range of Oregon reported that the variation in the isotopic signatures of surface water does not conform to the commonly observed “rainout effect”, which exhibits a trend of increasing isotopic depletion with rising elevation. The primary purpose of this research is to investigate the mechanisms governing seasonal and spatial variations in the isotopic signature of surface waters within the Marys River Basin, located in the leeward side of the Oregon Coastal Range. Surface water and precipitation samples were collected every 2-3 weeks for isotopic analysis of δ18O and δ2H for one year. Results indicate a significant difference in isotopic signature between watersheds underlain by basalt and sandstone. The degree of separation was the most distinct during the summer when low flows reflect deeper groundwater sources, whereas isotopic signatures during the rainy season (fall and winter) showed a greater degree of similarity between the two lithologies. This indicates that baseflow within streams drained by sandstone versus basalt is being supplied from two distinctly separate water sources. In addition, Marys River flow at the outle

  8. A silicon-based electrical source for surface plasmon polaritons

    NARCIS (Netherlands)

    Walters, Robert J.; van Loon, Rob V.A.; Brunets, I.; Schmitz, Jurriaan; Polman, Albert

    2009-01-01

    This work demonstrates the fabrication of a silicon-based electrical source for surface plasmon polaritons (SPPs) at low temperatures using silicon nanocrystal doped alumina within a metal-insulator-metal (MIM) waveguide geometry. The fabrication method uses established microtechnology processes

  9. A novel photobioreactor structure using optical fibers as inner light source to fulfill flashing light effects of microalgae.

    Science.gov (United States)

    Xue, Shengzhang; Zhang, Qinghua; Wu, Xia; Yan, Chenghu; Cong, Wei

    2013-06-01

    In this work, a novel photobioreactor structure using optical fibers being fixed vertically to culture flow direction as inner light source was proposed to fulfill flashing light effects (FLE) of microalgae, so as to obtain high light efficiency. Three types of optical-fiber photobioreactor fulfilling FLE of microalgae, i.e. air-driven panel, pump-driven panel and stirred tank type, were proposed and a 130 L airlift panel one was practically constructed on which both cold (light profile, liquid velocity) and hot model tests were carried out. Results demonstrated that it could produce uniformed light/dark frequencies being over 10 Hz and microalgae productivity increased by 43% and 38% for Spirulina platensis and Scenedesmus dimorphus respectively, compared with the control. This suggested the structure to be a viable and promising option for future photobioreactors. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Coherent artifact suppression in line-field reflection confocal microscopy using a low spatial coherence light source.

    Science.gov (United States)

    Liu, Changgeng; Cao, Hui; Choma, Michael A

    2016-10-15

    Line-field reflection confocal microscopy (LF-RCM) has the potential to add a dimension of parallelization to traditional confocal microscopy while reducing the need for two-axis beam scanning. LF-RCM systems often employ light sources with a high degree of spatial coherence. This high degree of spatial coherence potentially leads to unwanted coherent artifact in the setting of nontrivial sample scattering. Here, we (a) confirm that a coherent artifact is a nontrivial problem in LF-RCM when using spatially coherent light, and (b) demonstrate that such a coherent artifact can be mitigated through the use of reduced spatial coherence line-field sources. We demonstrate coherent noise suppression in a full-pupil line-field confocal microscope using a large number of mutually incoherent emitters from a vertical-cavity surface-emitting lasers (VCSEL) array. The coherent noise from a highly scattering sample is significantly suppressed by the use of this synthesized reduced spatial coherence light source compared to a fully coherent light source. Lastly, with scattering samples, the axial confocality of line-field confocal microscopy is compromised independent of the source spatial coherence, as demonstrated by our experimental result. Our results highlight the importance of spatial coherence engineering in parallelized reflection confocal microscopy.

  11. Ionization efficiency estimations for the SPES surface ion source

    Science.gov (United States)

    Manzolaro, M.; Andrighetto, A.; Meneghetti, G.; Rossignoli, M.; Corradetti, S.; Biasetto, L.; Scarpa, D.; Monetti, A.; Carturan, S.; Maggioni, G.

    2013-12-01

    Ion sources play a crucial role in ISOL (Isotope Separation On Line) facilities determining, with the target production system, the ion beam types available for experiments. In the framework of the SPES (Selective Production of Exotic Species) INFN (Istituto Nazionale di Fisica Nucleare) project, a preliminary study of the alkali metal isotopes ionization process was performed, by means of a surface ion source prototype. In particular, taking into consideration the specific SPES in-target isotope production, Cs and Rb ion beams were produced, using a dedicated test bench at LNL (Laboratori Nazionali di Legnaro). In this work the ionization efficiency test results for the SPES Ta surface ion source prototype are presented and discussed.

  12. Ultraviolet light depletes surface markers of Langerhans cells

    International Nuclear Information System (INIS)

    Aberer, W.; Schuler, G.; Stingl, G.; Hoenigsmann, H.; Wolff, K.

    1981-01-01

    This report defines the influence of ultraviolet light (UV) on Langerhans cells (LC). Human volunteers and hairless mice (Swiss ha/ha) were exposed to various single and/or cumulative doses of either UV-A, UV-B, or UV-A plus small amounts of UV-B (UV-A (+B)). 24 hr after the last irradiation, morphology of the entire epidermis was evaluated by both light and electron microscopy while LC, in addition, were tested for expression of specific histochemical (ATPase) and functional immunological markers (Ia antigens). In both men and mice, cumulative doses of either 80-120 J/cm2 UV-A (+B) or 1-2 X 100 J/cm2 UV-A resulted in a dramatic reduction of cells exhibiting ATPase and Ia-reactivity. In the UV-B spectrum, single doses of 60-80 mJ/cm2 produced a virtually complete elimination of LC membrane markers. By contrast, pemphigus antigens of keratinocytes were unaffected by these energy doses. Electron microscopy revealed cellular damage of some LC after UV-doses which produce a virtually complete abolition of LC membrane markers. At certain dose ranges (15-30 mJ/cm2 UV-B and 1 x 40 to 2 x 100 J/cm2 UV-A) LC were the only epidermal cells to display morphological damage at the ultrastructural level whereas higher doses affected all epidermal cells. The finding that LC surface markers and to a lesser extent the cells themselves are particularly susceptible to UV irradiation has important implications in view of previous findings that LC are potent stimulators of antigen-specific and allogeneic T cell activation. UV-induced alteration of LC plasma membrane integrity may represent a tool to manipulate adverse immune reactions involving the epidermis

  13. Playing the tricks of numbers of light sources

    International Nuclear Information System (INIS)

    Chen, Huanyang; Xu, Yadong; Li, Hui; Tyc, Tomáš

    2013-01-01

    Transformation optics has demonstrated its ability to design various novel devices, for example, to change objects' sizes, positions or even shapes. This time we come to another magical manipulation: to change the numbers of sources. In this paper, we will design a new class of gradient index lenses from multivalued optical conformal mapping. We shall call them the conformal lenses. Such lenses can make one active source appear omnidirectionally as two (or many) in-phase sources, each interfering with others. As a self-interference phenomenon, this has not been discussed before. Meanwhile, they can transform multiple in-phase sources into one. Other intriguing illusion effects are also demonstrated. Based on the Riemann sheet analysis, the physics mechanism of such effects are well explained. Finally, we apply transmutation methods to design lenses without any singular material parameters. (paper)

  14. Playing the tricks of numbers of light sources

    Science.gov (United States)

    Chen, Huanyang; Xu, Yadong; Li, Hui; Tyc, Tomáš

    2013-09-01

    Transformation optics has demonstrated its ability to design various novel devices, for example, to change objects' sizes, positions or even shapes. This time we come to another magical manipulation: to change the numbers of sources. In this paper, we will design a new class of gradient index lenses from multivalued optical conformal mapping. We shall call them the conformal lenses. Such lenses can make one active source appear omnidirectionally as two (or many) in-phase sources, each interfering with others. As a self-interference phenomenon, this has not been discussed before. Meanwhile, they can transform multiple in-phase sources into one. Other intriguing illusion effects are also demonstrated. Based on the Riemann sheet analysis, the physics mechanism of such effects are well explained. Finally, we apply transmutation methods to design lenses without any singular material parameters.

  15. In situ calibration of a light source in a sensor device

    Science.gov (United States)

    Okandan, Murat; Serkland, Darwin k.; Merchant, Bion J.

    2015-12-29

    A sensor device is described herein, wherein the sensor device includes an optical measurement system, such as an interferometer. The sensor device further includes a low-power light source that is configured to emit an optical signal having a constant wavelength, wherein accuracy of a measurement output by the sensor device is dependent upon the optical signal having the constant wavelength. At least a portion of the optical signal is directed to a vapor cell, the vapor cell including an atomic species that absorbs light having the constant wavelength. A photodetector captures light that exits the vapor cell, and generates an electrical signal that is indicative of intensity of the light that exits the vapor cell. A control circuit controls operation of the light source based upon the electrical signal, such that the light source emits the optical signal with the constant wavelength.

  16. White LED compared with other light sources: age-dependent photobiological effects and parameters for evaluation.

    Science.gov (United States)

    Rebec, Katja Malovrh; Klanjšek-Gunde, Marta; Bizjak, Grega; Kobav, Matej B

    2015-01-01

    Ergonomic science at work and living places should appraise human factors concerning the photobiological effects of lighting. Thorough knowledge on this subject has been gained in the past; however, few attempts have been made to propose suitable evaluation parameters. The blue light hazard and its influence on melatonin secretion in age-dependent observers is considered in this paper and parameters for its evaluation are proposed. New parameters were applied to analyse the effects of white light-emitting diode (LED) light sources and to compare them with the currently applied light sources. The photobiological effects of light sources with the same illuminance but different spectral power distribution were determined for healthy 4-76-year-old observers. The suitability of new parameters is discussed. Correlated colour temperature, the only parameter currently used to assess photobiological effects, is evaluated and compared to new parameters.

  17. (SUNY beamline facilities at the National Synchrotron Light Source)

    Energy Technology Data Exchange (ETDEWEB)

    Coppens, P.

    1992-01-01

    This report contains short discussions on the following topics which mainly deal with superconductors: crystallography; surface structure; scattering and EXAFS studies; small angle scattering of x-rays. (LSP)

  18. Numerical analysis of the beam position monitor pickup for the Iranian light source facility

    Science.gov (United States)

    Shafiee, M.; Feghhi, S. A. H.; Rahighi, J.

    2017-03-01

    In this paper, we describe the design of a button type Beam Position Monitor (BPM) for the low emittance storage ring of the Iranian Light Source Facility (ILSF). First, we calculate sensitivities, induced power and intrinsic resolution based on solving Laplace equation numerically by finite element method (FEM), in order to find the potential at each point of BPM's electrode surface. After the optimization of the designed BPM, trapped high order modes (HOM), wakefield and thermal loss effects are calculated. Finally, after fabrication of BPM, it is experimentally tested by using a test-stand. The results depict that the designed BPM has a linear response in the area of 2×4 mm2 inside the beam pipe and the sensitivity of 0.080 and 0.087 mm-1 in horizontal and vertical directions. Experimental results also depict that they are in a good agreement with numerical analysis.

  19. Optical-Fiber Fluorosensors With Polarized Light Sources

    Science.gov (United States)

    Egalon, Claudio O.; Rogowski, Robert S.

    1995-01-01

    Chemiluminescent and/or fluorescent molecules in optical-fiber fluorosensors oriented with light-emitting dipoles along transverse axis. Sensor of proposed type captures greater fraction of chemiluminescence or fluorescence and transmits it to photodetector. Transverse polarization increases sensitivity. Basic principles of optical-fiber fluorosensors described in "Making Optical-Fiber Chemical Sensors More Sensitive" (LAR-14525), "Improved Optical-Fiber Chemical Sensors" (LAR-14607), and "Improved Optical-Fiber Temperature Sensors" (LAR-14647).

  20. Alternatives to Outdoor Daylight Illumination for Photodynamic Therapy—Use of Greenhouses and Artificial Light Sources

    DEFF Research Database (Denmark)

    Lerche, Catharina; Heerfordt, Ida M; Heydenreich, Jakob

    2016-01-01

    -emitting diode (LED) lamp, red LED panel and lamps used for conventional PDT. Four of the five light sources were able to photobleach PpIX completely. For halogen light and the red LED lamp, 5000 lux could photobleach PpIX whereas 12,000 lux were needed for the white LED lamp. Furthermore, the greenhouse...... was suitable for daylight PDT since the effect of solar light is lowered only by 25%. In conclusion, we found four of the five light sources and the greenhouse usable for indoor daylight PDT. The greenhouse is beneficial when the weather outside is rainy or windy. Only insignificant ultraviolet B radiation...

  1. 49 CFR Appendix B to Part 564 - Information To Be Submitted for Long Life Replaceable Light Sources of Limited Definition

    Science.gov (United States)

    2010-10-01

    ...—Information To Be Submitted for Long Life Replaceable Light Sources of Limited Definition I. Filament or... Source that Operates With a Ballast and Rated Life of the Light Source/Ballast Combination. A. Maximum power (in watts). B. Luminous Flux (in lumens). C. Rated laboratory life of the light source/ballast...

  2. Real-time tunability of chip-based light source enabled by microfluidic mixing

    DEFF Research Database (Denmark)

    Olsen, Brian Bilenberg; Rasmussen, Torben; Balslev, Søren

    2006-01-01

    We demonstrate real-time tunability of a chip-based liquid light source enabled by microfluidic mixing. The mixer and light source are fabricated in SU-8 which is suitable for integration in SU-8-based laboratory-on-a-chip microsystems. The tunability of the light source is achieved by changing...... the concentration of rhodamine 6G dye inside two integrated vertical resonators, since both the refractive index and the gain profile are influenced by the dye concentration. The effect on the refractive index and the gain profile of rhodamine 6G in ethanol is investigated and the continuous tuning of the laser...

  3. Current status and future perspectives of accelerator-based x-ray light sources

    Science.gov (United States)

    Tanaka, Takashi

    2017-09-01

    State-of-the-art x-ray light sources are nowadays based on large-scale electron accelerators, because the synchrotron radiation (SR) and x-ray free electron laser (XFEL) radiation generated by high-energy electron beams have many advantages over other alternatives in terms of the wavelength tunability, high brightness and flux, high coherence, flexible polarization states, and so on. This is the reason why SR and XFEL light sources have largely contributed to the evolution of x-ray science. This paper reviews the current status of such accelerator-based x-ray light source facilities and discusses their future perspectives.

  4. The effect of scattered light sensor orientation on roughness measurement of curved polished surfaces

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo

    with crossed surface lay to document the robustness of the method. The instrument area-integrating measuring principle (figure 1) is based on a non-coherent light beam of ∅ 0.9 mm and 670 nm wavelength illuminating the measured surface, reflection of the incident light from the surface slopes in spatial......The effect of angular orientation of a scattered light sensor with respect to main curvature and surface lay on roughness measurements is evaluated. A commercial scattered light sensor OS 500-32 from Optosurf GmbH was used. The investigation was performed on polished cylindrical surfaces...... directions, and its acquisition within ± 16º angular range with a linear detector array. From the distribution of the acquired scattered light intensity, a number of statistical parameters describing the surface texture are calculated, where the Aq parameter (variance of the scattered light distribution...

  5. Proposal of coherent Cherenkov radiation matched to circular plane wave for intense terahertz light source

    International Nuclear Information System (INIS)

    Sei, Norihiro; Sakai, Takeshi; Hayakawa, Ken; Tanaka, Toshinari; Hayakawa, Yasushi; Nakao, Keisuke; Nogami, Kyoko; Inagaki, Manabu

    2015-01-01

    Highlights: • We proposed a new intense terahertz-wave source based on coherent Cherenkov radiation (CCR). • A hollow conical dielectric is used to generate the CCR beam. • The wave front of the CCR beam can be matched to the basal plane. • The peak-power of the CCR beam is above 1 MW per micropulse with a short interval of 350 ps. - Abstract: We propose a high-peak-power terahertz-wave source based on an electron accelerator. By passing an electron beam through a hollow conical dielectric with apex facing the incident electron beam, the wave front of coherent Cherenkov radiation generated on the inner surface of the hollow conical dielectric matches the basal plane. Using the electron beam generated at the Laboratory for Electron Beam Research and Application at Nihon University, the calculated power of coherent Cherenkov radiation that matched the circular plane (CCR-MCP) was above 1 MW per micropulse with a short interval of 350 ps, for wavelengths ranging from 0.5 to 5 mm. The electron beam is not lost for generating the CCR-MCP beam by using the hollow conical dielectric. It is possible to combine the CCR-MCP beams with other light sources based on an accelerator

  6. Using the combination refraction-reflection solid to design omni-directional light source used in underwater wireless optical communication

    Science.gov (United States)

    Rao, Jionghui; Yao, Wenming; Wen, Linqiang

    2015-10-01

    Underwater wireless optical communication is a communication technology which uses laser as an information carrier and transmits data through water. Underwater wireless optical communication has some good features such as broader bandwidth, high transmission rate, better security, anti—interference performance. Therefore, it is promising to be widely used in the civil and military communication domains. It is also suitable for high-speed, short-range communication between underwater mobile vehicles. This paper presents a design approach of omni-directional light source used in underwater wireless optical communication, using TRACEPRO simulation tool to help design a combination solid composed of the lens, conical reflector and parabolic reflector, and using the modulated DPSS green laser in the transmitter module to output the laser beam in small divergence angles, after expanded by the combination refraction-reflection solid, the angle turns into a space divergence angle of 2π, achieving the omni-directional light source of hemisphere space, and test in the air and underwater, the result shows that the effect is fine. This paper analyzes the experimental test in the air and water, in order to make further improvement of the uniformity of light distribution, we optimize the reflector surface parameters of combination refraction-reflection solid and test in the air and water. The result shows that omni-directional light source used in underwater wireless optical communication optimized could achieve the uniformity of light distribution of underwater space divergence angle of 2π. Omni-directional light source used in underwater wireless optical communication designed in this paper has the characteristics of small size and uniformity of light distribution, it is suitable for application between UUVs, AUVs, Swimmer Delivery Vehicles (SDVs) and other underwater vehicle fleet, it realizes point-to-multipoint communications.

  7. NIJI-III superconducting compact light source facility

    International Nuclear Information System (INIS)

    Emura, Katsuji; Haga, Tsuyoshi; Shinzato, Tsuyoshi; Takada, Hiroshi

    1995-01-01

    Sumitomo Electric Industries established a synchrotron radiation (SR) facility named 'Harima Research Laboratories' in 1993. The facility is located in Harima Science Garden City where the large SR facility 'Spring-8' is being under construction. Main purpose of our laboratory is to develop the advanced technologies on SR application, particularly for micro-fabrication, photochemistry and x-ray tomography. In the facility, a 600 MeV superconducting compact SR ring 'NIJI-III', a 100 MeV compact linac and five beamlines have been installed. Nowadays, NIJI-III usually provides SR light to users for 16 hours in a day. (author)

  8. Undulator based scanning microscope at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Rarback, H.; Shu, D.; Ade, H.; Jacobsen, C.; Kirz, J.; McNulty, I.; Rosser, R.

    1986-01-01

    A second generation scanning soft x-ray microscope is under construction, designed to utilize the dramatic increase in source bightness available at the soft x-ray undulator. The new instrument is expected to reduce image acquisition time by a factor of about 100, and to improve resolution, stability, and reproducibility

  9. Development of infrared water sensors based on novel light sources

    Science.gov (United States)

    Donohue, John R.; Masterson, Hugh J.; Maze, Gwenael; O'Dwyer, Kieran; MacCraith, Brian D.

    2003-03-01

    The detection and measurement of vapour-phase or liquid-phase water is important in many industrial and chemical processes. Water exhibits strong absorption bands compared to other substances in the near infrared (NIR), and for this reason NIR spectroscopy is especially well suited to moisture determination. A lack of suitable sources in the NIR, however, has impeded the application of optical sensors to water detection. We have developed a modulatable IR source for use in a moisture sensor. In the system, the luminescent emission from optically pumped rare earth doped glasses is used. Thulium doped zirconium fluoride glass, which luminesces at 1.83 mm was the material chosen. The spectral overlap with the water absorption band is significant, and the output stability matches that of the pump source, which is typically an internally modulated diode laser emitting at 685nm. The detection system uses a reference beam and a probe beam to monitor changes in absorption due to moisture or water vapour. Results illustrating the effectiveness of the novel IR source in a sensor platform to measure trace amounts of liquid water and water vapor will be presented.

  10. Dazzling new light source opens at Stanford synchrotron radiation laboratory

    CERN Multimedia

    2004-01-01

    SPEAR3, the Stanford Positron Electron Asymmetric Ring, was formally opened at a dedication ceremony at the Stanford Linear Accelerator Center on Jan. 29. It incorporates the latest technology to make it competitive with the best synchrotron sources in the world (1/2 page)

  11. Light source characterization and air movement under CIE S 025

    DEFF Research Database (Denmark)

    Thorseth, Anders; Bergen, A. S. J.

    2017-01-01

    as well as requirements for the performance of testing and measurement equipment. One of the environmental considerations is a restriction of the airflow incident on the device under test. The sensitivity of LED source based devices to airflow is important for estimating the uncertainty originating from...

  12. Effectiveness of different light sources for 5-aminolevulinic acid photodynamic therapy.

    Science.gov (United States)

    Juzeniene, Asta; Juzenas, Petras; Ma, Li-Wei; Iani, Vladimir; Moan, Johan

    2004-01-01

    Many medical applications, including photodynamic therapy for cancer (PDT), involve the use of lasers. However, the coherence of laser light is not necessary for PDT, and attempts have been made to construct non-coherent light sources for PDT, which are relatively inexpensive, stable and easy to operate, require simple maintenance but differ fundamentally from the lasers in their output characteristics. In the present work we compared two clinically used lamps, CureLight1, which is a broadband source (560-740 nm) based on a filtered halogen lamp, and CureLight2, which is a narrowband source based on light-emitting diodes (LEDs), with respect to several parameters of crucial significance for PDT efficiency in vivo: (a) depth of action in tissues, (b) heating effects, (c) pain generation, (d) photodegradation of PpIX in solution, in cells and in mouse skin and (e) photo-inactivation of cells in vitro. We conclude that CureLight2 (LED), relative to CureLight1 (halogen) has deeper PDT action in tissue, similar efficiency for bleaching PpIX in mouse skin, better efficiency for bleaching PpIX in cells and solutions and good efficiency for inactivating cells in vitro. CureLight2 gives less heating of the tissue and less pain in unsensitised human skin. All these differences are related to difference in the spectra of the lamps. Thus, PDT light sources with emissions that are visually similar have significantly different photobiological properties.

  13. Source effects on surface waves from Nevada Test Site explosions

    International Nuclear Information System (INIS)

    Patton, H.J.; Vergino, E.S.

    1981-11-01

    Surface waves recorded on the Lawrence Livermore National Laboratory (LLNL) digital network have been used to study five underground nuclear explosions detonated in Yucca Valley at the Nevada Test Site. The purpose of this study is to characterize the reduced displacement potential (RDP) at low frequencies and to test secondary source models of underground explosions. The observations consist of Rayleigh- and Love-wave amplitude and phase spectra in the frequency range 0.03 to 0.16 Hz. We have found that Rayleigh-wave spectral amplitudes are modeled well by a RDP with little or no overshoot for explosions detonated in alluvium and tuff. On the basis of comparisons between observed and predicted source phase, the spall closure source proposed by Viecelli does not appear to be a significant source of Rayleigh waves that reach the far field. We tested two other secondary source models, the strike-slip, tectonic strain release model proposed by Toksoez and Kehrer and the dip-slip thrust model of Masse. The surface-wave observations do not provide sufficient information to discriminate between these models at the low F-values (0.2 to 0.8) obtained for these explosions. In the case of the strike-slip model, the principal stress axes inferred from the fault slip angle and strike angle are in good agreement with the regional tectonic stress field for all but one explosion, Nessel. The results of the Nessel explosion suggest a mechanism other than tectonic strain release

  14. Total luminous flux measurement for flexible surface sources with an integrating sphere photometer

    International Nuclear Information System (INIS)

    Yu, Hsueh-Ling; Liu, Wen-Chun

    2014-01-01

    Applying an integrating sphere photometer for total luminous flux measurement is a widely used method. However, the measurement accuracy depends on the spatial uniformity of the integrating sphere, especially when the test sample has a different light distribution from that of the standard source. Therefore, spatial correction is needed to eliminate the effect caused by non-uniformity. To reduce the inconvenience of spatial correction but retain the measurement accuracy, a new type of working standard is designed for flexible and curved surface sources. Applying this new type standard source, the measurement deviation due to different orientations is reduced by an order of magnitude compared with using a naked incandescent lamp as the standard source. (paper)

  15. On the reflection point where light reflects to a known destination on quadratic surfaces.

    Science.gov (United States)

    Gonçalves, Nuno

    2010-01-15

    We address the problem of determining the reflection point on a specular surface where a light ray that travels from a source to a target is reflected. The specular surfaces considered are those expressed by a quadratic equation. So far, there is no closed form explicit equation for the general solution of this determination of the reflection point, and the usual approach is to use the Snell law or the Fermat principle whose equations are derived in multidimensional nonlinear minimizations. We prove in this Letter that one can impose a set of three restrictions to the reflection point that can impose a set of three restrictions that culminates in a very elegant formalism of searching the reflection point in a unidimensional curve in space. This curve is the intersection of two quadratic equations. Some applications of this framework are also discussed.

  16. Interaction of the wood surface with metal ions. Part 3: The effects of light on chromium impregnated wood surface

    International Nuclear Information System (INIS)

    Stipta, J.; Németh, K.; Molnárné Hamvas, L.

    2004-01-01

    UV-light changes of untreated and chromium impregnated wood surface were investigated by absorption spectrophotometric methods. The properties of indifferent silicagel and celulose layers were to the behaviour of poplar and black locust surface. Chromic-ion-impregnation had no significant effect on the absorption spectra of these layers. On the other hand, hexavalent chromium was reduced and UV-light caused irreversible wood degradation. Surface treatment caused considerable modification in black locust

  17. Development of a clockwork light source to enable cervical inspection by village health workers

    Directory of Open Access Journals (Sweden)

    Steventon Richard

    2002-12-01

    Full Text Available Abstract Background Cervical cancer can often be prevented by screening and may be curable if identified and treated in its early stages. However, 80% of new cases occur in less-developed countries where cervical cancer screening programmes are small-scale or non-existent. This is a human tragedy of great proportion, with many of those affected being young mothers. There is some evidence that cancerous or precancerous lesions may be detected by visual inspection with acetic acid (VIA and field studies indicate that this technique is effective, safe and acceptable to women. However, the provision of a light source for inspection of the cervix presents a major problem in less-developed countries, where candles and torches often provide the only means of illumination. Our objective was to develop a light source based on clockwork technology, that required no batteries or external power source. Methods We adapted the design of a commercially available clockwork torch to provide a light source for cervical inspection. The light source was then tested under laboratory conditions in a comparison with other illumination methods typically used in this application. Results The light source gave illuminance levels greater than those produced by any other method tested, and also had considerable advantages in terms of ease of use and safety. Conclusion This design is small, compact, effective and safe to use and promises a better and more affordable means of visualising the cervix. Further field trials of VIA are now required which incorporate this light source.

  18. Characterization of germanium linear kinoform lenses at Diamond Light Source.

    Science.gov (United States)

    Alianelli, L; Sawhney, K J S; Tiwari, M K; Dolbnya, I P; Stevens, R; Jenkins, D W K; Loader, I M; Wilson, M C; Malik, A

    2009-05-01

    The unprecedented brilliance achieved by third-generation synchrotron sources and the availability of improved optics have opened up new opportunities for the study of materials at the micrometre and nanometre scale. Focusing the synchrotron radiation to smaller and smaller beams is having a huge impact on a wide research area at synchrotrons. The key to the exploitation of the improved sources is the development of novel optics that deliver narrow beams without loss of brilliance and coherence. Several types of synchrotron focusing optics are successfully fabricated using advanced miniaturization techniques. Kinoform refractive lenses are being developed for hard X-ray beamlines, and the first test results at Diamond are discussed in this paper.

  19. Self-Calibration Method Based on Surface Micromaching of Light Transceiver Focal Plane for Optical Camera

    Directory of Open Access Journals (Sweden)

    Jin Li

    2016-10-01

    Full Text Available In remote sensing photogrammetric applications, inner orientation parameter (IOP calibration of remote sensing camera is a prerequisite for determining image position. However, achieving such a calibration without temporal and spatial limitations remains a crucial but unresolved issue to date. The accuracy of IOP calibration methods of a remote sensing camera determines the performance of image positioning. In this paper, we propose a high-accuracy self-calibration method without temporal and spatial limitations for remote sensing cameras. Our method is based on an auto-collimating dichroic filter combined with a surface micromachining (SM point-source focal plane. The proposed method can autonomously complete IOP calibration without the need of outside reference targets. The SM procedure is used to manufacture a light transceiver focal plane, which integrates with point sources, a splitter, and a complementary metal oxide semiconductor sensor. A dichroic filter is used to fabricate an auto-collimation light reflection element. The dichroic filter, splitter, and SM point-source focal plane are integrated into a camera to perform an integrated self-calibration. Experimental measurements confirm the effectiveness and convenience of the proposed method. Moreover, the method can achieve micrometer-level precision and can satisfactorily complete real-time calibration without temporal or spatial limitations.

  20. Pulsed-laser micropatterned quantum-dot array for white light source

    Science.gov (United States)

    Wang, Sheng-Wen; Lin, Huang-Yu; Lin, Chien-Chung; Kao, Tsung Sheng; Chen, Kuo-Ju; Han, Hau-Vei; Li, Jie-Ru; Lee, Po-Tsung; Chen, Huang-Ming; Hong, Ming-Hui; Kuo, Hao-Chung

    2016-03-01

    In this study, a novel photoluminescent quantum dots device with laser-processed microscale patterns has been demonstrated to be used as a white light emitting source. The pulsed laser ablation technique was employed to directly fabricate microscale square holes with nano-ripple structures onto the sapphire substrate of a flip-chip blue light-emitting diode, confining sprayed quantum dots into well-defined areas and eliminating the coffee ring effect. The electroluminescence characterizations showed that the white light emission from the developed photoluminescent quantum-dot light-emitting diode exhibits stable emission at different driving currents. With a flexibility of controlling the quantum dots proportions in the patterned square holes, our developed white-light emitting source not only can be employed in the display applications with color triangle enlarged by 47% compared with the NTSC standard, but also provide the great potential in future lighting industry with the correlated color temperature continuously changed in a wide range.

  1. Science and Technology of Future Light Sources: A White Paper

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, Uwe; Corlett, John; Dierker, Steve; Falcone, Roger; Galayda, John; Gibson, Murray; Hastings, Jerry; Hettel, Bob; Hill, John; Hussain, Zahid; Kao, Chi-Chang; Kirz, a= Janos; Long, Gabrielle; McCurdy, Bill; Raubenheimer, Tor; Sannibale, Fernando; Seeman, John; Shen, Z.-X.; Shenoy, Gopal; Schoenlein, Bob; Shen, Qun; /Argonne /Brookhaven /LBL, Berkeley /SLAC, SSRL

    2009-02-03

    Many of the important challenges facing humanity, including developing alternative sources of energy and improving health, are being addressed by advances that demand the improved understanding and control of matter. While the visualization, exploration, and manipulation of macroscopic matter have long been technological goals, scientific developments in the twentieth century have focused attention on understanding matter on the atomic scale through the underlying framework of quantum mechanics. Of special interest is matter that consists of natural or artificial nanoscale building blocks defined either by atomic structural arrangements or by electron or spin formations created by collective correlation effects (Figure 1.1). The essence of the challenge to the scientific community has been expressed in five grand challenges for directing matter and energy recently formulated by the Basic Energy Sciences Advisory Committee [1]. These challenges focus on increasing our understanding of, and ultimately control of, matter at the level of atoms, electrons. and spins, as illustrated in Figure 1.1, and serve the entire range of science from advanced materials to life sciences. Meeting these challenges will require new tools that extend our reach into regions of higher spatial, temporal, and energy resolution. X-rays with energies above 10 keV offer capabilities extending beyond the nanoworld shown in Figure 1.1 due to their ability to penetrate into optically opaque or thick objects. This opens the door to combining atomic level information from scattering studies with 3D information on longer length scales from real space imaging with a resolution approaching 1 nm. The investigation of multiple length scales is important in hierarchical structures, providing knowledge about function of living organisms, the atomistic origin of materials failure, the optimization of industrial synthesis, or the working of devices. Since the fundamental interaction that holds matter

  2. National synchrotron light source. [Annual report], October 1, 1992--September 30, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Rothman, E.Z.; Hulbert, S.L.; Lazarz, N.M. [eds.

    1994-04-01

    This report contains brief discussions on the research being conducted at the National Synchrotron Light source. Some of the topics covered are: X-ray spectroscopy; nuclear physics; atomic and molecular science; meetings and workshops; operations; and facility improvements.

  3. Scanning soft x-ray microscopy with a fresnel zoneplate at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Kenney, J.M.; Kirz, J.; Rarback, H.; Feder, R.; Sayre, D.; Howells, M.

    1983-01-01

    We have built a scanning transmission soft x-ray microscope located at the National Synchrotron Light Source (NSLS). Images of biological specimens have been formed with submicron resolution. A Fresnel zoneplate serves as the focusing element

  4. Design and Optimisation Strategies of Nonlinear Dynamics for Diffraction Limited Synchrotron Light Source

    CERN Document Server

    Bartolini, R.

    2016-01-01

    This paper introduces the most recent achievements in the control of nonlinear dynamics in electron synchrotron light sources, with special attention to diffraction limited storage rings. Guidelines for the design and optimization of the magnetic lattice are reviewed and discussed.

  5. Atomic physics research with second and third generation synchrotron light sources

    International Nuclear Information System (INIS)

    Johnson, B.M.

    1990-10-01

    This contribution to these proceedings is intended to provide an introduction and overview for other contributions on atomic (and related) physics research at existing and planned synchrotron light sources. The emphasis will be on research accomplishments and future opportunities, but a comparison will be given of operating characteristics for first, second, and third generation machines. First generation light sources were built to do research with the primary electron and positron beams, rather than with the synchrotron radiation itself. Second generation machines were specifically designed to be dedicated synchrotron-radiation facilities, with an emphasis on the use of bending-magnet radiation. The new third generation light sources are being designed to optimize radiation from insertion devices, such as undulators and wigglers. Each generation of synchrotron light source offers useful capabilities for forefront research in atomic physics and many other disciplines. 27 refs., 1 fig., 3 tabs

  6. National synchrotron light source. [Annual report], October 1, 1992--September 30, 1993

    International Nuclear Information System (INIS)

    Rothman, E.Z.; Hulbert, S.L.; Lazarz, N.M.

    1994-04-01

    This report contains brief discussions on the research being conducted at the National Synchrotron Light source. Some of the topics covered are: X-ray spectroscopy; nuclear physics; atomic and molecular science; meetings and workshops; operations; and facility improvements

  7. High-brightness electron guns for linac-based light sources

    International Nuclear Information System (INIS)

    Lewellen, J.W.

    2004-01-01

    Most proposed linac-based light sources, such as single-pass free-electron lasers and energy-recovery-linacs, require very high-brightness electron beams in order to achieve their design performance. These beam requirements must be achieved not on an occasional basis, but rather must be met by every bunch produced by the source over extended periods of time. It is widely assumed that the beam source will be a photocathode electron gun; the selection of accelerator technique (e.g., dc or rf) for the gun is more dependent on the application.The current state of the art of electron beam production is adequate but not ideal for the first generation of linac-based light sources, such as the Linac Coherent Light Source (LCLS) x-ray free-electron laser (X-FEL). For the next generation of linac-based light sources, an order of magnitude reduction in the transverse electron beam emittance is required to significantly reduce the cost of the facility. This is beyond the present state of the art, given the other beam properties that must be maintained. The requirements for current and future linac-based light source beam sources are presented here, along with a review of the present state of the art. A discussion of potential paths towards meeting future needs is presented at the conclusion.

  8. Surface Plasmon Enhanced Phosphorescent Organic Light Emitting Diodes

    International Nuclear Information System (INIS)

    Bazan, Guillermo; Mikhailovsky, Alexander

    2008-01-01

    The objective of the proposed work was to develop the fundamental understanding and practical techniques for enhancement of Phosphorescent Organic Light Emitting Diodes (PhOLEDs) performance by utilizing radiative decay control technology. Briefly, the main technical goal is the acceleration of radiative recombination rate in organometallic triplet emitters by using the interaction with surface plasmon resonances in noble metal nanostructures. Increased photonic output will enable one to eliminate constraints imposed on PhOLED efficiency by triplet-triplet annihilation, triplet-polaron annihilation, and saturation of chromophores with long radiative decay times. Surface plasmon enhanced (SPE) PhOLEDs will operate more efficiently at high injection current densities and will be less prone to degradation mechanisms. Additionally, introduction of metal nanostructures into PhOLEDs may improve their performance due to the improvement of the charge transport through organic layers via multiple possible mechanisms ('electrical bridging' effects, doping-like phenomena, etc.). SPE PhOLED technology is particularly beneficial for solution-fabricated electrophosphorescent devices. Small transition moment of triplet emitters allows achieving a significant enhancement of the emission rate while keeping undesirable quenching processes introduced by the metal nanostructures at a reasonably low level. Plasmonic structures can be introduced easily into solution-fabricated PhOLEDs by blending and spin coating techniques and can be used for enhancement of performance in existing device architectures. This constitutes a significant benefit for a large scale fabrication of PhOLEDs, e.g. by roll-to-roll fabrication techniques. Besides multieexciton annihilation, the power efficacy of PhOLEDs is often limited by high operational bias voltages required for overcoming built-in potential barriers to injection and transport of electrical charges through a device. This problem is especially

  9. Surface Plasmon Enhanced Phosphorescent Organic Light Emitting Diodes

    Energy Technology Data Exchange (ETDEWEB)

    Guillermo Bazan; Alexander Mikhailovsky

    2008-08-01

    The objective of the proposed work was to develop the fundamental understanding and practical techniques for enhancement of Phosphorescent Organic Light Emitting Diodes (PhOLEDs) performance by utilizing radiative decay control technology. Briefly, the main technical goal is the acceleration of radiative recombination rate in organometallic triplet emitters by using the interaction with surface plasmon resonances in noble metal nanostructures. Increased photonic output will enable one to eliminate constraints imposed on PhOLED efficiency by triplet-triplet annihilation, triplet-polaron annihilation, and saturation of chromophores with long radiative decay times. Surface plasmon enhanced (SPE) PhOLEDs will operate more efficiently at high injection current densities and will be less prone to degradation mechanisms. Additionally, introduction of metal nanostructures into PhOLEDs may improve their performance due to the improvement of the charge transport through organic layers via multiple possible mechanisms ('electrical bridging' effects, doping-like phenomena, etc.). SPE PhOLED technology is particularly beneficial for solution-fabricated electrophosphorescent devices. Small transition moment of triplet emitters allows achieving a significant enhancement of the emission rate while keeping undesirable quenching processes introduced by the metal nanostructures at a reasonably low level. Plasmonic structures can be introduced easily into solution-fabricated PhOLEDs by blending and spin coating techniques and can be used for enhancement of performance in existing device architectures. This constitutes a significant benefit for a large scale fabrication of PhOLEDs, e.g. by roll-to-roll fabrication techniques. Besides multieexciton annihilation, the power efficacy of PhOLEDs is often limited by high operational bias voltages required for overcoming built-in potential barriers to injection and transport of electrical charges through a device. This problem is

  10. My Precious! The Location and Diffusion of Scientific Research: Evidence from the Synchrotron Diamond Light Source

    OpenAIRE

    Christian Helmers; Henry Overman

    2013-01-01

    We analyze the impact of the establishment of a GBP 380 million basic scientific research facility in the UK on the geographical distribution of related research. We investigate whether the siting of the Diamond Light Source, a 3rd generation synchrotron light source, in Oxfordshire induced a clustering of related research in its geographic proximity. To account for the potentially endogenous location choice of the synchrotron, we exploit the availability of a `runner-up' site near Manchester...

  11. Project planning workshop 6-GeV synchrotron light source: Volume 1

    International Nuclear Information System (INIS)

    1986-01-01

    A model 6 GeV synchrotron light source is described, and the costs, schedule, and manpower associated with producing such a synthrotron light source are summarized. A program consisting of a two-year pre-construction phase, a five-year construction phase, and a three-year post-construction phase and costing a total of $379.6 million is assumed

  12. Development of Advanced Fourth Generation Light Sources for the Accelerator Science Laboratory

    OpenAIRE

    Chanwattana, Thakonwat; Bartolini, Riccardo; Seryi, Andrei; Tsesmelis, Emmanuel

    2015-01-01

    The John Adams Institute for Accelerator Science (JAI) has proposed the realisation of the Accelerator Science Laboratory (ASL) at the University of Oxford as a facility for the development of advanced compact light sources enabling accelerator science research and applications. The installation of a compact light source in the ASL is planned with two options for the accelerating technologies. Firstly, a conventional RF based accelerator is considered to be a driver for a short pulse THz cohe...

  13. Monochromatic light-emitting diode (LED source in layers hens during the second production cycle

    Directory of Open Access Journals (Sweden)

    Rodrigo Borille

    2015-09-01

    Full Text Available ABSTRACTLight is an important environmental factor for birds, allowing not only their vision, but also influencing their physiological responses, such as behavioral and reproductive activity. The objective of this experiment was to evaluate the impact of different colors of monochromatic light (LED sources in laying hens production during the second laying cycle. The study was conducted in an experimental laying house during 70 days. A total of 300 laying hens Isa Brown® genetic strain, aged 95 weeks, in the second laying cycle were used in the study. The artificial light sources used were blue, yellow, green, red and white. The light regimen was continuous illumination of 17 h per day (12 h natural and 5 h artificial in a daily light regimen of 17L:5D (light: dark. The Latin Square design was adopted with five treatments (five colors divided into five periods, and five boxes, with six replicates of ten birds in each box. The production and egg quality were evaluated. The different colors of light source did not affect production parameters or egg quality (p > 0.05. The monochromatic light source may be considered as an alternative to artificial lighting in laying hens during the second production cycle.

  14. History of Science and Conceptual Change: The Formation of Shadows by Extended Light Sources

    Science.gov (United States)

    Dedes, Christos; Ravanis, Konstantinos

    2009-01-01

    This study investigates the effectiveness of a teaching conflict procedure whose purpose was the transformation of the representations of 12-16-year-old pupils in Greece concerning light emission and shadow formation by extended light sources. The changes observed during the children's effort to destabilize and reorganise their representations…

  15. Application of Photocatalysts and LED Light Sources in Drinking Water Treatment

    Directory of Open Access Journals (Sweden)

    Gopal Achari

    2013-09-01

    Full Text Available This study investigates a cross-section of TiO2 compositions for which existing evidence suggests the prospect of improved performance compared to standard Degussa P25. In the context of a program aimed toward a 365 nm LED based photo-reactor, the question is whether a distinctly superior photocatalyst composition for drinking water treatment is now available that would shape design choices. An answer was sought by synthesizing several photocatalysts with reported high reactivity in some context in the literature, and by performing photocatalysts reactivity tests using common pollutants of water system including Natural Organic Matter (NOM and Emerging Contaminants (ECs from the pesticide and pharmaceutical classes. 365 nm Light Emitting Diodes (LEDs were used as the irradiation source. Since LEDs are now available in the UV, we did not examine the TiO2 modifications that bring band gap excitation into the region beyond 400 nm. The results suggest that the choice of the photocatalyst should be best made to fit the reactor design and photocatalyst mounting constraints such as mass transport, reactive surface, and light field. No photocatalyst composition overall, superior for all classes emerged.

  16. Analysis of CMOS hot carrier light sources using back-end-of-line light directing structures for improved light extraction efficiency

    Science.gov (United States)

    Bulling, Anthony F.; Venter, Petrus J.; du Plessis, Monuko

    2014-06-01

    Light emission from silicon is possible in CMOS through hot carrier electroluminescence. Low conversion and low extraction efficiency remains a challenge. By using existing back-end-of-line interconnect structures it is possible to improve the extraction efficiency. Such light directing structures were analysed with the use of a focused ion beam and scanning electron microscope. It was found that it is possible to improve light extraction efficiency and directionality of the light sources through a combination of back-end-of-line structures and field oxide manipulation resulting in an improved optical path for emitted photon radiation. However, further analysis indicates that total internal reflections, scattering and electromagnetic absorption from the via plugs and metal interconnects in the back-end-of-line stack are some of the key contributors to the inefficient light extraction efficiency.

  17. Comparison of fipronil sources in North Carolina surface water ...

    Science.gov (United States)

    Fipronil is a phenylpyrazole insecticide that is widely used in residential and agricultural settings to control ants, roaches, termites, and other pests. Fipronil and its transformation products have been found in a variety of environmental matrices, but the source[s] which makes the greatest contribution to fipronil in surface water has yet to be determined. A sampling effort designed to prioritize known fipronil inputs (golf courses, residential areas, biosolids application sites and wastewater facilities) was conducted in North Carolina to learn more about the origins of fipronil in surface water. High resolution mass spectrometry (HRMS) analysis indicated that fipronil and its known derivatives were routinely present in all samples, but concentrations were substantially elevated near wastewater treatment plant outfalls (range 10–500 ng/L combined), suggesting that they predominate as environmental sources. Corresponding recycled wastewater samples, which were treated with NaOCl for disinfection, showed disappearance of fipronil and all known degradates. HRMS and nuclear magnetic resonance (NMR) analysis techniques were used to determine that all fipronil-related compounds are oxidized to a previously unidentified fipronil sulfone chloramine species in recycled wastewater. The implications of the presence of a new fipronil-related compound in recycled wastewater need to be considered. Journal Article Highlights • The most important sources of fipronil in

  18. The Mean Curvature of the Influence Surface of Wave Equation With Sources on a Moving Surface

    Science.gov (United States)

    Farassat, F.; Farris, Mark

    1999-01-01

    The mean curvature of the influence surface of the space-time point (x, t) appears in linear supersonic propeller noise theory and in the Kirchhoff formula for a supersonic surface. Both these problems are governed by the linear wave equation with sources on a moving surface. The influence surface is also called the Sigma - surface in the aeroacoustic literature. This surface is the locus, in a frame fixed to the quiescent medium, of all the points of a radiating surface f(x, t) = 0 whose acoustic signals arrive simultaneously to an observer at position x and at the time t. Mathematically, the Sigma- surface is produced by the intersection of the characteristic conoid of the space-time point (x, t) and the moving surface. In this paper, we derive the expression for the local mean curvature of the Sigma - space of the space-time point for a moving rigid or deformable surface f(x, t) = 0. This expression is a complicated function of the geometric and kinematic parameters of the surface f(x, t) = 0. Using the results of this paper, the solution of the governing wave equation of high speed propeller noise radiation as well as the Kirchhoff formula for a supersonic surface can be written as very compact analytic expression.

  19. Broadband light source for fiber-optic measurement system in spaceborne applications

    Science.gov (United States)

    Rößner, Max R.; Müller, Mathias S.; Buck, Thorbjörn C.; Koch, Alexander W.

    2012-01-01

    Measuring temperatures, mechanical loads and derived quantities precisely and reliably play an important role in spaceflight. With spacecraft becoming increasingly complex, upscaling of present telemetry techniques can become cumbersome. Additionally, there are entirely new sensory requirements, resulting from emerging technologies such as smart structures, active vibration damping and composite material health monitoring. It has been demonstrated in preceding studies that these measurements can be advantageously and efficiently carried out by means of fiber-optic systems. The most prominent fiber-optic strain and temperature sensor is the fiber Bragg grating. Typically, multiple fiber Bragg gratings are used to translate entire temperature and strain fields into an optical wavelength information. For the interrogation of these sensors, a broadband or scanning light source is required. Additional requirements with respect to the light source are high intensity and unpolarized illumination of the gratings. These constraints can be met by a light source that is based on amplified spontaneous emission in a rare-earth-doped fiber. In the presented work, a compact light source, adapted for measurement applications and targeted towards space applications, has been developed. The design of this light source is presented, as well as its implementation. The light source has been designed and tested for selected core aspects of space robustness and the results of these tests are summarized.

  20. Ultrafast X-ray science at the Advanced Light Source

    International Nuclear Information System (INIS)

    Schoenlein, R.W.; Chin, A.H.; Chong, H.H.W.; Falcone, R.W.; Glover, T.E.; Heimann, P.A.; Johnson, S.L.; Lindenberg, A.M.; Shank, C.V.; Zholents, A.A.; Zolotorev, M.S.

    2000-01-01

    Our scientific understanding of the static or time-averaged structure of condensed matter on the atomic scale has been dramatically advanced by direct structural measurements using x-ray techniques and modern synchrotron sources. Of course the structure of condensed matter is not static, and to understanding the behavior of condensed matter at the most fundamental level requires structural measurements on the time scale on which atoms move. The evolution of condensed-matter structure, via the making and breaking of chemical bonds and the rearrangement of atoms, occurs on the fundamental time scale of a vibrational period, ∼100 fs. Atomic motion and structural dynamics on this time scale ultimately determine the course of phase transitions in solids, the kinetic pathways of chemical reactions, and even the efficiency and function of biological processes. The integration of x-ray measurement techniques, a high-brightness femtosecond x-ray source, femtosecond lasers, and stroboscopic pump-probe techniques will provide the unique capability to address fundamental scientific questions in solid-state physics, chemistry, AMO physics, and biology involving structural dynamics. In this paper, we review recent work in ultrafast x-ray science at the ALS including time-resolved diffraction measurements and efforts to develop dedicated beamlines for femtosecond x-ray experiments

  1. A beamline for macromolecular crystallography at the Advanced Light Source

    International Nuclear Information System (INIS)

    Padmore, H.A.; Earnest, T.; Kim, S.H.; Thompson, A.C.; Robinson, A.L.

    1994-08-01

    A beamline for macromolecular crystallography has been designed for the ALS. The source will be a 37-pole wiggler with a, 2-T on-axis peak field. The wiggler will illuminate three beamlines, each accepting 3 mrad of horizontal aperture. The central beamline will primarily be used for multiple-wavelength anomalous dispersion measurements in the wavelength range from 4 to 0.9 angstrom. The beamline optics will comprise a double-crystal monochromator with a collimating pre-mirror and a double-focusing mirror after the monochromator. The two side stations will be used for fixed-wavelength experiments within the wavelength range from 1.5 to 0.95 angstrom. The optics will consist of a conventional vertically focusing cylindrical mirror followed by an asymmetrically cut curved-crystal monochromator. This paper presents details of the optimization of the wiggler source for crystallography, gives a description of the beamline configuration, and discusses the reasons for the choices made

  2. Light source effects on aerosol photoacoustic spectroscopy measurements

    Science.gov (United States)

    Radney, James G.; Zangmeister, Christopher D.

    2017-01-01

    Photoacoustic spectroscopy measurements of flame-generated soot aerosol coated with small amounts of water yielded absorption enhancements that were dependent on the laser used: quasi-continuous wave (Q-CW, ≈650 ps pulse duration and 78 MHz repetition rate) versus continuous wave (CW). Water coating thickness was controlled by exposing the aerosol to a set relative humidity (RH). At ≈85% RH, the mass of the soot particles increased by an amount comparable to a monolayer of water being deposited and enhanced the measured absorption by 36% and 15% for the Q-CW and CW lasers, respectively. Extinction measurements were also performed using a cavity ring-down spectrometer (extinction equals the sum of absorption and scattering) with a CW laser and negligible enhancement was observed at all RH. These findings demonstrate that source choice can impact measurements of aerosols with volatile coatings and that the absorption enhancements at high RH previously measured by Radney and Zangmeister [1] are the result of laser source used (Q-CW) and not from an increase in the particle absorption cross section.

  3. Comparison of stray light in spectrometer systems using a low cost monochromatic light source

    DEFF Research Database (Denmark)

    Thorseth, Anders; Lindén, Johannes; Dam-Hansen, Carsten

    2014-01-01

    We present an experimental setup that is under development for automated stray light characterization of spectrometers. The setup uses a tuneable monochromator which enables this characterization on relatively cost low equipment. We present the measured line spread functions for two spectrometers...

  4. Light-induced retinal damage using different light sources, protocols and rat strains reveals LED phototoxicity.

    Science.gov (United States)

    Krigel, A; Berdugo, M; Picard, E; Levy-Boukris, R; Jaadane, I; Jonet, L; Dernigoghossian, M; Andrieu-Soler, C; Torriglia, A; Behar-Cohen, F

    2016-12-17

    To save energy, the European directives from the Eco-design of Energy Using Products (2005/32/CE) have recommended the replacement of incandescent lamps by more economic devices such as Light Emitting Diodes (LEDs). However, the emission spectrum of these devices is enriched in blue radiations, known to be potentially dangerous to the retina. Recent studies showed that light exposure contributes to the onset of early stages of age-related macular degeneration (AMD). Here, we investigate, in albinos and pigmented rats, the effects of different exposure protocols. Twenty-four hours exposure at high luminance was compared to a cyclic (dark/light) exposure at domestic levels for 1week and 1month, using different LEDs (Cold-white, blue and green), as well as fluorocompact bulbs and fluorescent tubes. The data suggest that the blue component of the white-LED may cause retinal toxicity at occupational domestic illuminance and not only in extreme experimental conditions, as previously reported. It is important to note that the current regulations and standards have been established on the basis of acute light exposure and do not take into account the effects of repeated exposure. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.

  5. Source Surface Models and Their Impact on Solar Wind Research

    Science.gov (United States)

    Sokolov, I. V.; Roussev, I. I.; Gombosi, T. I.; Liu, Y.

    2005-05-01

    To perform realistic modeling of the important processes in the solar corona, such as coronal mass ejections, flares, as well as the acceleration of solar particles, one needs to incorporate into the physical models any complicated pattern of the coronal magnetic field. The coronal magnetic field topology is determined by the helmet streamers (with closed field lines), the coronal holes (with open field lines) as well as the fine, but crucially important, details of the small-scale active regions. The standard practice to recover the global 3-D structure of the solar magnetic field from observations is to use the source surface model, in which the field is assumed to be potential, i.e., current-free. This approach ignores any volumetric current there may be present in the corona, and also neglects the existence of the equatorial current sheet, which starts from a height of 3-5 Rs above the solar surface. The fully potential solar magnetic field would have only closed field lines, not allowing for the solar wind to exist. In our Solar Corona model, incorparated into the Space Weather Modelling Framework, the solar magnetic field is split into two constituitive parts: one potential part which is recovered from the magnetic field data (e.g., from WSO, MWO, or MDI data) using the source surface method; and, one other non-potential part. For the potential field, we keep only the spherical harmonics decreasing with distance from the Sun or, equivalently, we use a very large value of the source surface radius. For the non-potential field, we solve the time-dependent induction equation with zero boundary condition at the solar surface. The full set of conservation laws for the MHD system is solved numerically using the BATS-R-US code. To power the solar wind in our model, we use a phenomenological turbulence model described in an earlier paper. The resulting steady-state MHD solution includes the well-resolved current sheet and helmet streamers. The modeled structure of

  6. Subwavelength propagation and localization of light using surface ...

    Indian Academy of Sciences (India)

    2014-01-09

    Jan 9, 2014 ... didate to propagate and localize light at subwavelength scales. By tailoring the geometry ... optics and spectroscopy. Here we focus on plasmon-assisted light propagation and confinement in coupled ..... In spite of being a very useful technique, it is very challenging to trap metallic particles because of their ...

  7. Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay.

    Science.gov (United States)

    Delferrière, O; Gobin, R; Harrault, F; Nyckees, S; Sauce, Y; Tuske, O

    2012-02-01

    One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

  8. Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclaya)

    Science.gov (United States)

    Delferrière, O.; Gobin, R.; Harrault, F.; Nyckees, S.; Sauce, Y.; Tuske, O.

    2012-02-01

    One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

  9. Progress with ELETTRA, the synchrotron light source in Trieste

    International Nuclear Information System (INIS)

    Puglisi, M.; Wrulich, A.

    1991-01-01

    ELETTRA, the 3rd generation synchrotron radiation source under construction in Trieste has passed the design phase. The present schedule calls for a start of commissioning by the second half of 1993. The buildings are under construction and prototypes for all main components of the accelerator complex have been constructed and industrial production has started. A high power cavity fully equipped with cooling circuit and input coupling loop, as well as mechanical tuning system, has been tested and measured. Prototype cavities equipped with higher order mode suppressors are under development. In-house prototypes for each magnet type have been built and magnetic measurements have been performed. The vacuum chamber prototype has been baked under vacuum and tested with its pumping system. A prototype pure permanent magnet undulator has been assembled and measured. The first 100 MeV sections of the 1.5 GeV injection linac will go in operation in August 1990

  10. 3D-surface reconstruction method for diffuse optical tomography phantoms and tissues using structured and polarized light

    Science.gov (United States)

    Baum, K.; Hartmann, R.; Bischoff, T.; Himmelreich, F.; Heverhagen, J. T.

    2011-07-01

    In recent years optical methods became increasingly popular for pre-clinical research and small animal imaging. One main field in biomedical optics research is the diffuse optical tomography (DOT). Many new systems were invented for small animal imaging and breast cancer detection. In combination with the progress in the development of optical markers, optical detectors and near infrared light sources, these new systems have become a formidable source of information. Most of the systems detect the transmitted light which passes through an object and one observes the intensity variations on the detector side. The biggest challenge for all diffuse optical tomography systems is the enormous scattering of light in tissues and tissue-like phantoms resulting in loss of image information. Many systems work with contact gels and optical fibers that have direct contact with the object to neglect the light path between surface and detector. Highly developed mathematic models and reconstruction algorithms based on FEM and Monte Carlo simulations describe the light transport inside tissues and determine differences in absorption and scattering coefficients inside. The proposed method allows a more exact description of the orientation of surface elements from semi-transparent objects towards the detector. Using Polarization Difference Imaging (PDI) in combination with structured light 3D-scanning, it is possible to separate information from the surface from that of the subsurface. Thus, the actual surface shape can be determined. Furthermore, overlaying byproducts caused by inter-reflections and multiple scattering can be filtered from the basic image information with this method. To enhance the image quality, the intensity dispersion between surface and camera is calculated and the creation of 3D-FEM-meshes simplified.

  11. Photobiological interactions of blue light and photosynthetic photon flux: effects of monochromatic and broad-spectrum light sources.

    Science.gov (United States)

    Cope, Kevin R; Snowden, M Chase; Bugbee, Bruce

    2014-01-01

    Photosynthesis (Pn) and photomorphogenesis (Pm) are affected by light quality, light intensity and photoperiod. Although blue light (BL) is necessary for normal development, it is less efficient in driving Pn than other wavelengths of photosynthetically active radiation. The effects of BL on Pm are highly species dependent. Here we report the interacting effects of BL and photosynthetic photon flux (PPF) on growth and development of lettuce, radish and pepper. We used light-emitting diode (LED) arrays to provide BL fractions from 11% to 28% under broad-spectrum white LEDs, and from 0.3% to 92% under monochromatic LEDs. All treatments were replicated three times at each of two PPFs (200 and 500 μmol m(-2) s(-1)). Other than light quality, environmental conditions were uniformly maintained across chambers. Regardless of PPF, BL was necessary to prevent shade-avoidance responses in radish and lettuce. For lettuce and radish, increasing BL reduced stem length, and for both species, there were significant interactions of BL with PPF for leaf expansion. Increasing BL reduced petiole length in radish and flower number in pepper. BL minimally affected pepper growth and other developmental parameters. Pepper seedlings were more photobiologically sensitive than older plants. Surprisingly, there were few interactions between monochromatic and broad-spectrum light sources. © 2013 The American Society of Photobiology.

  12. Correspondence: In support of the IES method of evaluating light source colour rendition

    Energy Technology Data Exchange (ETDEWEB)

    Houser, Kevin W.; Royer, Michael P.; Whitehead, Lorne

    2015-11-20

    In this editorial, written as an open letter to the lighting community, we stand in support of widespread adoption of TM-30-15: The IES Method of Evaluating Light Source Color Rendition. We introduce important considerations related to light source color rendition, define the need for a new method of evaluation, provide a high-level overview of the IES method, discuss some of the practical considerations related to the development of the IES method and the consensus process, and conclude by inviting you to join us in support of the new measures and graphics described in TM-30-15.

  13. Stimulated-emission-depletion microscopy with a multicolor stimulated-Raman-scattering light source.

    Science.gov (United States)

    Rankin, Brian R; Kellner, Robert R; Hell, Stefan W

    2008-11-01

    We describe a subdiffraction-resolution far-field fluorescence microscope employing stimulated emission depletion (STED) with a light source consisting of a microchip laser coupled into a standard single-mode fiber, which, via stimulated Raman scattering (SRS), yields a comb-like spectrum of seven discrete peaks extending from the fundamental wavelength at 532 nm to 620 nm. Each of the spectral peaks can be used as STED light for overcoming the diffraction barrier. This SRS light source enables the simple implementation of multicolor STED and provides a spectral output with multiple available wavelengths from green to red with potential for further expansion.

  14. Multi-wavelength mid-IR light source for gas sensing

    Science.gov (United States)

    Karioja, Pentti; Alajoki, Teemu; Cherchi, Matteo; Ollila, Jyrki; Harjanne, Mikko; Heinilehto, Noora; Suomalainen, Soile; Viheriälä, Jukka; Zia, Nouman; Guina, Mircea; Buczyński, Ryszard; Kasztelanic, Rafał; Kujawa, Ireneusz; Salo, Tomi; Virtanen, Sami; Kluczyński, Paweł; Sagberg, Hâkon; Ratajczyk, Marcin; Kalinowski, Przemyslaw

    2017-02-01

    Cost effective multi-wavelength light sources are key enablers for wide-scale penetration of gas sensors at Mid-IR wavelength range. Utilizing novel Mid-IR Si-based photonic integrated circuits (PICs) filter and wide-band Mid-IR Super Luminescent Light Emitting Diodes (SLEDs), we show the concept of a light source that covers 2.5…3.5 μm wavelength range with a resolution of market impact is expected to be disruptive, since the devices currently in the market are either complicated, expensive and heavy instruments, or the applied measurement principles are inadequate in terms of stability and selectivity.

  15. A scanning photoelectron microscope (SPEM) at the National Synchrotron Light Source (NSLS)

    International Nuclear Information System (INIS)

    Ade, H.; Kirz, J.; Hulbert, S.; Johnson, E.; Anderson, E.; Kern, D.; Brookhaven National Lab., Upton, NY; Lawrence Berkeley Lab., CA; International Business Machines Corp., Yorktown Heights, NY

    1989-01-01

    We are in the process of developing and commissioning a scanning photoelectron microscope (SPEM) at the X1A beamline of the National Synchrotron Light Source (NSLS). It is designed to make use of the Soft X-ray Undulator (SXU) at the NSLS. This high brightness source illuminates a Fresnel zone plate, which forms a focused probe, ≤ 0.2μm in size, on the specimen surface. A grating monochromator selects the photon energy in the 400-800 eV range with an energy resolution of better than 1 eV. The expected flux in the focus is in the 5 x 10 7 - 10 9 photons/s range. A single pass Cylindrical Mirror Analyzer (CMA) is used to record photoemission spectra, or to form an image within a fixed electron energy bandwidth as the specimen is mechanically scanned. As a first test, a 1000 mesh Au grid was successfully imaged with a resolution of about 1μm and the CMA tuned to the Au 4 f photoelectron peak. Once it is commissioned, a program is planned which will utilize the microscope to study beam sensitive systems, such as thin oxide/sub-oxide films of alumina and silica, and ultimately various adsorbates on these films. 14 refs., 4 figs

  16. Report of the Basic Energy Sciences Workshop on Compact Light Sources

    Energy Technology Data Exchange (ETDEWEB)

    Barletta, William A. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Borland, Michael [Argonne National Lab. (ANL), Argonne, IL (United States)

    2010-05-11

    This report is based on a BES Workshop on Compact Light Sources, held May 11-12, 2010, to evaluated the advantages and disadvantages of compact light source approaches and compared their performance to the third generation storage rings and free-electron lasers. The workshop examined the state of the technology for compact light sources and their expected progress. The workshop evaluated the cost efficiency, user access, availability, and reliability of such sources. Working groups evaluated the advantages and disadvantages of Compact Light Source (CLS) approaches, and compared their performance to the third-generation storage rings and free-electron lasers (FELs). The primary aspects of comparison were 1) cost effectiveness, 2) technical availability v. time frame, and 3) machine reliability and availability for user access. Five categories of potential sources were analyzed: 1) inverse Compton scattering (ICS) sources, 2) mini storage rings, 3) plasma sources, 4) sources using plasma-based accelerators, and 5) laser high harmonic generation (HHG) sources. Compact light sources are not a substitute for large synchrotron and FEL light sources that typically also incorporate extensive user support facilities. Rather they offer attractive, complementary capabilities at a small fraction of the cost and size of large national user facilities. In the far term they may offer the potential for a new paradigm of future national user facility. In the course of the workshop, we identified overarching R&D topics over the next five years that would enhance the performance potential of both compact and large-scale sources: Development of infrared (IR) laser systems delivering kW-class average power with femtosecond pulses at kHz repetition rates. These have application to ICS sources, plasma sources, and HHG sources. Development of laser storage cavities for storage of 10-mJ picosecond and femtosecond pulses focused to micron beam sizes. Development of high-brightness, high

  17. Light transmittance and surface roughness of a feldspathic ceramic CAD-CAM material as a function of different surface treatments.

    Science.gov (United States)

    Ural, Çağrı; Duran, İbrahim; Evmek, Betül; Kavut, İdris; Cengiz, Seda; Yuzbasioglu, Emir

    2016-07-15

    The aim of the present study was to determine the effect of different surface treatments on light transmission of aesthetic feldspathic ceramics used in CAD-CAM chairside restorations. Forty eight feldspatic ceramic test specimens were prepared from prefabricated CAD-CAM blocks by using a slow speed diamond saw. Test specimens were prepared and divided into 4 groups (n = 12). In the control group, no surface treatments were applied on the feldspathic ceramic surfaces. In the hydrofluoric acid group, the bonding surfaces of feldspathic ceramics were etched with 9.5 % hydrofluoric acid. In the sandblasting group the feldspathic ceramic surfaces were air-abraded with 30-μm alumium oxide (Al2O3) particles and Er:YAG laser was used to irradiate the ceramic surfaces. The incident light power given by the LED device and the transmitted light power through each ceramic sample was registered using a digital LED radiometer device. Each polymerization light had a light guide with 8-mm-diameter tips. Light transmission of feldspathic ceramic samples was determined by placing it on the radiometer and irradiating the specimen for 10 s at the highest setting for each light polymerization. All specimens were coated with gold using a sputter coater and examined under a field emission scanning electron microscope. Surface roughness measurement each group were evaluated with 3D optical surface and tactile profilometers. One-way ANOVA test results revealed that both surface conditioning method significantly affect the light transmittance (F:412.437; p ceramic material below the value of 400 mW/cm(2) which is critical limit for safe polymerization.

  18. Visible-light-induced surface graft polymerization via camphorquinone impregnation technique.

    Science.gov (United States)

    Ziani-Cherif, Houcine; Abe, Yusuke; Imachi, Kou; Matsuda, Takehisa

    2002-02-01

    A surface modification method that is particularly applicable to complexly shaped fabricated devices has long been awaited. In this article, we describe the visible-light-induced surface photograft polymerization technique by which an inner surface of the device is modified by visible-light irradiation through the external surface. Comphorquione, as a photoradical initiator, was impregnated on a segmented polyurethane surface by solvent soaking, followed by visible-light irradiation in the presence of monomers such as acrylamide and poly(ethylene glycol) methacrylate. The resultant surfaces were highly wettable with water, and surface chemical compositional analysis by X-ray photoelectron spectroscopy revealed that the surface was graft-polymerized with these monomers. The simple and widespread applicability of this surface modification technique to biomedical devices is discussed. Copyright 2001 John Wiley & Sons, Inc. J Biomed Mater Res 59: 386-389, 2002

  19. Conjugation of fiber-coupled wide-band light sources and acousto-optical spectral elements

    Science.gov (United States)

    Machikhin, Alexander; Batshev, Vladislav; Polschikova, Olga; Khokhlov, Demid; Pozhar, Vitold; Gorevoy, Alexey

    2017-12-01

    Endoscopic instrumentation is widely used for diagnostics and surgery. The imaging systems, which provide the hyperspectral information of the tissues accessible by endoscopes, are particularly interesting and promising for in vivo photoluminescence diagnostics and therapy of tumour and inflammatory diseases. To add the spectral imaging feature to standard video endoscopes, we propose to implement acousto-optical (AO) filtration of wide-band illumination of incandescent-lamp-based light sources. To collect maximum light and direct it to the fiber-optic light guide inside the endoscopic probe, we have developed and tested the optical system for coupling the light source, the acousto-optical tunable filter (AOTF) and the light guide. The system is compact and compatible with the standard endoscopic components.

  20. Enhanced catalytic activity without the use of an external light source using microwave-synthesized CuO nanopetals

    Directory of Open Access Journals (Sweden)

    Govinda Lakhotiya

    2017-05-01

    Full Text Available We report enhanced catalytic activity of CuO nanopetals synthesized by microwave-assisted wet chemical synthesis. The catalytic reaction of CuO nanopetals and H2O2 was studied with the application of external light source and also under dark conditions for the degradation of the hazardous dye methylene blue. The CuO nanopetals showed significant catalytic activity for the fast degradation of methylene blue and rhodamine B (RhB under dark conditions, without the application of an external light source. This increased catalytic activity was attributed to the co-operative role of H2O2 and the large specific surface area (≈40 m2·g−1 of the nanopetals. We propose a detail mechanism for this fast degradation. A separate study of the effect of different H2O2 concentrations for the degradation of methylene blue under dark conditions is also illustrated.

  1. Blind source identification from the multichannel surface electromyogram

    International Nuclear Information System (INIS)

    Holobar, A; Farina, D

    2014-01-01

    The spinal circuitries combine the information flow from the supraspinal centers with the afferent input to generate the neural codes that drive the human skeletal muscles. The muscles transform the neural drive they receive from alpha motor neurons into motor unit action potentials (electrical activity) and force. Thus, the output of the spinal cord circuitries can be examined noninvasively by measuring the electrical activity of skeletal muscles at the surface of the skin i.e. the surface electromyogram (EMG). The recorded multi-muscle EMG activity pattern is generated by mixing processes of neural sources that need to be identified from the recorded signals themselves, with minimal or no a priori information available. Recently, multichannel source separation techniques that rely minimally on a priori knowledge of the mixing process have been developed and successfully applied to surface EMG. They act at different scales of information extraction to identify: (a) the activation signals shared by synergistic skeletal muscles, (b) the specific neural activation of individual muscles, separating it from that of nearby muscles i.e. from crosstalk, and (c) the spike trains of the active motor neurons. This review discusses the assumptions made by these methods, the challenges and limitations, as well as examples of their current applications. (topical review)

  2. Contribution to the study of the molecular scattering of light. Use of a laser as light source (1963)

    International Nuclear Information System (INIS)

    Slama, L.

    1963-01-01

    The experiments of the molecular scattering of light have been repeated using a ruby laser as a light source. The angular distribution of the scattered light intensity has been measured when the electric vector of the incident beam is either in the plane of observation or perpendicular to that plane. In the first case a good agreement with the Rayleigh theory has been found but this is not true in the second case. The differential cross sections for scattering have been measured for various gases. The values found are two or three times larger than the ones deduced from the classical theory. The possible effect of a variation of the beam intensity upon the linearity of the scattering process has been looked for. (author) [fr

  3. Light-emitting-diode Lambertian light sources as low-radiant-flux standards applicable to quantitative luminescence-intensity imaging

    Science.gov (United States)

    Yoshita, Masahiro; Kubota, Hidehiro; Shimogawara, Masahiro; Mori, Kaneo; Ohmiya, Yoshihiro; Akiyama, Hidefumi

    2017-09-01

    Planar-type Lambertian light-emitting diodes (LEDs) with a circular aperture of several tens of μ m to a few mm in diameter were developed for use as radiant-flux standard light sources, which have been in strong demand for applications such as quantitative or absolute intensity measurements of weak luminescence from solid-state materials and devices. Via pulse-width modulation, time-averaged emission intensity of the LED devices was controlled linearly to cover a wide dynamic range of about nine orders of magnitude, from 10 μ W down to 10 fW. The developed planar LED devices were applied as the radiant-flux standards to quantitative measurements and analyses of photoluminescence (PL) intensity and PL quantum efficiency of a GaAs quantum-well sample. The results demonstrated the utility and applicability of the LED standards in quantitative luminescence-intensity measurements in Lambertian-type low radiant-flux level sources.

  4. Photoacoustic thermal flowmetry with a single light source

    Science.gov (United States)

    Liu, Wei; Lan, Bangxin; Hu, Leo; Chen, Ruimin; Zhou, Qifa; Yao, Junjie

    2017-09-01

    We report a photoacoustic thermal flowmetry based on optical-resolution photoacoustic microscopy (OR-PAM) using a single laser source for both thermal tagging and photoacoustic excitation. When an optically absorbing medium is flowing across the optical focal zone of OR-PAM, a small volume of the medium within the optical focus is repeatedly illuminated and heated by a train of laser pulses with a high repetition rate. The average temperature of the heated volume at each laser pulse is indicated by the photoacoustic signal excited by the same laser pulse due to the well-established linear relationship between the Grueneisen coefficient and the local temperature. The thermal dynamics of the heated medium volume, which are closely related to the flow speed, can therefore be measured from the time course of the detected photoacoustic signals. Here, we have developed a lumped mathematical model to describe the time course of the photoacoustic signals as a function of the medium's flow speed. We conclude that the rising time constant of the photoacoustic signals is linearly dependent on the flow speed. Thus, the flow speed can be quantified by fitting the measured photoacoustic signals using the derived mathematical model. We first performed proof-of-concept experiments using defibrinated bovine blood flowing in a plastic tube. The experiment results have demonstrated that the proposed method has high accuracy (˜±6%) and a wide range of measurable flow speeds. We further validated the method by measuring the blood flow speeds of the microvasculature in a mouse ear in vivo.

  5. Intense, broadband, pulsed I-R source at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Williams, G.P.

    1984-01-01

    We describe a broadband (1 μm to 1 mm) synchrotron radiation infrared source, pulsed each 20 to 180 nseconds and delivering about 10 15 photons/sec/1% bandpass into f10 optics. The source size is diffraction limited. This source is thus 100 to 1000 times brighter than a 2000 0 K black body, very stable and capable of being used for calibration

  6. Brillouin light scattering from surface acoustic waves in a subwavelength-diameter optical fibre.

    Science.gov (United States)

    Beugnot, Jean-Charles; Lebrun, Sylvie; Pauliat, Gilles; Maillotte, Hervé; Laude, Vincent; Sylvestre, Thibaut

    2014-10-24

    Brillouin scattering in optical fibres is a fundamental interaction between light and sound with important implications ranging from optical sensors to slow and fast light. In usual optical fibres, light both excites and feels shear and longitudinal bulk elastic waves, giving rise to forward-guided acoustic wave Brillouin scattering and backward-stimulated Brillouin scattering. In a subwavelength-diameter optical fibre, the situation changes dramatically, as we here report with the first experimental observation of Brillouin light scattering from surface acoustic waves. These Rayleigh-type surface waves travel the wire surface at a specific velocity of 3,400 m s(-1) and backscatter the light with a Doppler shift of about 6 GHz. As these acoustic resonances are sensitive to surface defects or features, surface acoustic wave Brillouin scattering opens new opportunities for various sensing applications, but also in other domains such as microwave photonics and nonlinear plasmonics.

  7. Synchrotron light source data book: Version 4, Revision 05/96

    International Nuclear Information System (INIS)

    Murphy, J.B.

    1996-05-01

    This book is as its name implies a collection of data on existing and planned synchrotron light sources. The intention was to provide a compendium of tools for the design of electron storage rings as synchrotron radiation sources. The slant is toward the accelerator physicist as other booklets such as the X-Ray Data Booklet address the use of synchrotron radiation. It is hoped that the booklet serves as a pocket sized reference to facilitate back of the envelope type calculations. It contains some useful formulae in practical units and a brief description of many of the existing and planned light source lattices

  8. Experimental study on source efficiencies for estimating surface contamination level

    International Nuclear Information System (INIS)

    Ichiji, Takeshi; Ogino, Haruyuki

    2008-01-01

    Source efficiency was measured experimentally for various materials, such as metals, nonmetals, flooring materials, sheet materials and other materials, contaminated by alpha and beta emitter radioactive nuclides. Five nuclides, 147 Pm, 60 Co, 137 Cs, 204 Tl and 90 Sr- 90 Y, were used as the beta emitters, and one nuclide 241 Am was used as the alpha emitter. The test samples were prepared by placing drops of the radioactive standardized solutions uniformly on the various materials using an automatic quantitative dispenser system from Musashi Engineering, Inc. After placing drops of the radioactive standardized solutions, the test materials were allowed to dry for more than 12 hours in a draft chamber with a hood. The radioactivity of each test material was about 30 Bq. Beta rays or alpha rays from the test materials were measured with a 2-pi gas flow proportional counter from Aloka Co., Ltd. The source efficiencies of the metals, nonmetals and sheet materials were higher than 0.5 in the case of contamination by the 137 Cs, 204 Tl and 90 Sr- 90 Y radioactive standardized solutions, higher than 0.4 in the case of contamination by the 60 Co radioactive standardized solution, and higher than 0.25 in the case of contamination by the alpha emitter the 241 Am radioactive standardized solution. These values were higher than those given in Japanese Industrial Standards (JIS) documents. In contrast, the source efficiencies of some permeable materials were lower than those given in JIS documents, because source efficiency varies depending on whether the materials or radioactive sources are wet or dry. This study provides basic data on source efficiency, which is useful for estimating the surface contamination level of materials. (author)

  9. The effect of microwave/laboratory light source postcuring technique and wet-aging on microhardness of composite resin

    Directory of Open Access Journals (Sweden)

    Farahnaz Sharafeddin

    2013-01-01

    Full Text Available Background: Although composite restorations are really valuable for esthetic zones, they have shown less longevity rather than amalgam restorations. Since it may be related to the method used for curing the composite, postcuring could increase the degree of conversion and result in more long-lasting composite restorations. This study was planned to evaluate the effect of two different postcuring techniques on microhardness of indirect composite resin after wet-aging and comparing them with the direct type. Materials and Methods: In this experimental study, 99 composite disk-shaped (6.5 × 2.5 mm specimens of composite (Gradia GC, Japan were prepared in split mold. The indirect composite specimens were postcured by laboratory light source (Labolite LV-III GC Corp, Japan or microwave unit (MC 2002 JR, LG, Korea. Then, the aging procedure was done for 24 h, 30 and 180 days in distilled water. The Vicker′s Hardness test (VHN on surface of specmens was measured by Wolpert microhardness tester and the data were analyzed by the two-way analysis of variance (ANOVA and Tukey′s post hoc tests. (P ≤ 0.05. Results: The statistical analysis revealed that surface microhardness of postcured composite by microwave and laboratory light source was more than that of direct composite ( P = 0.0001 and postcuring by microwave was more effective than postcuring by laboratory light source ( P = 0.004. The 30 days stored composite demonstrated significant decrease of VHN compared with the 24-h stored samples ( P = 0.0001, with a more significant VHN decrease after 180 days of aging ( P = 0.045. Conclusion: Postcuring increased the surface microhardness and aging reduced the surface microhardness of indirect composite.

  10. Source attribution of insoluble light-absorbing particles in seasonal snow across northern China

    Directory of Open Access Journals (Sweden)

    R. Zhang

    2013-06-01

    Full Text Available Seasonal snow samples obtained at 46 sites in 6 provinces of China in January and February 2010 were analyzed for a suite of chemical species and these data are combined with previously determined concentrations of insoluble light-absorbing particles (ILAP, including all particles that absorb light in the 650–700 nm wavelength interval. The ILAP, together with 14 other analytes, are used as input to a positive matrix factorization (PMF receptor model to explore the sources of ILAP in the snow. The PMF analysis for ILAP sources is augmented with backward trajectory cluster analysis and the geographic locations of major source areas for the three source types. The two analyses are consistent and indicate that three factors/sources were responsible for the measured light absorption of snow: a soil dust source, an industrial pollution source, and a biomass and / or biofuel burning source. Soil dust was the main source of the ILAP, accounting for ~53% of ILAP on average.

  11. The efficient model to define a single light source position by use of high dynamic range image of 3D scene

    Science.gov (United States)

    Wang, Xu-yang; Zhdanov, Dmitry D.; Potemin, Igor S.; Wang, Ying; Cheng, Han

    2016-10-01

    One of the challenges of augmented reality is a seamless combination of objects of the real and virtual worlds, for example light sources. We suggest a measurement and computation models for reconstruction of light source position. The model is based on the dependence of luminance of the small size diffuse surface directly illuminated by point like source placed at a short distance from the observer or camera. The advantage of the computational model is the ability to eliminate the effects of indirect illumination. The paper presents a number of examples to illustrate the efficiency and accuracy of the proposed method.

  12. Photoenhanced uptakes of NO2 by indoor surfaces: A new HONO source

    Science.gov (United States)

    Gligorovski, S.; Bartolomei, V.; Soergel, M.; Gomez Alvarez, E.; Zetzsch, C.; Wortham, H.

    2012-12-01

    Nitrous acid (HONO) is a known household pollutant that can lead to human respiratory tract irritation. HONO acts as the nitrosating agent, e.g. by the formation of the so-called third-hand smoke after wall reactions of HONO with nicotine (1). HONO can be generated indoors directly during combustion processes or indirectly via heterogeneous NO2 reactions with adsorbed water on diverse surfaces (2). Recently a new source was identified as another path of HONO formation in the troposphere (3). Namely, the light-induced heterogeneous reaction of NO2 with adsorbed organics (known as photosensitizers) on various surfaces such as roads, buildings, rocks or plants leads to enhanced HONO production. The detected values of HONO indoors vary in the range between 2 and 25 parts per billion (ppb). However, like outdoors, the processes leading to HONO formation indoors are not completely understood (4). Indoor photolysis radiation sources include exterior sunlight (λ>350 nm) that enters typically through the windows and indoor illumination sources, i.e., rare gas/mercury fluorescent light bulbs and tungsten and tungsten/halogen light bulbs among others. The present work is showing the importance of indoor sources of HONO recently identified or postulated. We have tested a number of common household chemical agents commonly used for cleaning purposes or coatings of domestic surfaces to better identify different indoor HONO sources. We used a heterogeneous flow tube technique to test the HONO production potentials of these household chemical agents under different experimental conditions, namely with and without light and at different relative humidity levels and different NO2 concentrations. We report uptake kinetics measurements of the heterogeneous reaction of gas phase NO2 with lacquer and paint coated on the walls of the reactor. The flow tube was irradiated with four near-ultraviolet (UV) emitting lamps (range of wavelengths 300-420nm). We observed that the heterogeneous

  13. Measuring light spectrum as a main indicator of artificial sources quality

    Directory of Open Access Journals (Sweden)

    Piotr Dąbrowski

    2015-05-01

    Full Text Available Objective: To compare different artificial light sources in different places where plant breeding is conduced. Methods: Measurements were conducted outdoor, in room, in greenhouse, under four panels with light emitting diodes, in phytotron, in dark room with various light sources and inside Sanyo versatile environmental chamber. The measurements were made by using SpectraPen SP100 (PSI, Czech Republic device. Results: Our result showed that spectrum measured outdoor during sunny day had only one peak at the wavelength of 485 nm (ca. 60000 relative units. On cloudy day, the trend of light spectrum curve was similar, but with lower values. At room conditions, the curve was more flat than outdoor. Under greenhouse conditions, the curve was similar to that measured outdoor. A few additional peaks on the curve appeared by adding high pressure sodium lamp. There were changes of curve under LED panels. Conclusions: It must be underlined that the most similar spectrum curve to daylight light has incandescent bulb and this light source should be preferred as support of daylight in greenhouses and as main source in phytotrons. Using high pressure sodium lamp in greenhouses as support of daylight cause increase in the red/far-red ratio and occurrence of a new peak on spectrum curve. The new possibilities are creating by LED panels with red and blue diodes.

  14. Current and future studies of actinides materials at the advanced light source

    International Nuclear Information System (INIS)

    Shuh, D.K.

    2002-01-01

    The vacuum ultraviolet (VUV)/soft X-ray region of the synchrotron radiation (SR) spectrum has revolutionized the approach to surface materials chemistry/physics. This spectral region has long been recognised for its potential to afford investigations of fundamental actinide science and to provide an improved analytical surface characterisation capabilities for actinide materials. Previously, the actinide science community was unable to take advantage of the opportunities afforded by VUV/soft X-ray SR methodologies because of radiological safety concerns and the need to prepare pristine actinide materials compatible with experiments in ultra-high vacuum end stations. With the advent of third-generation light sources operating in the VUV/soft X-ray region, such as the Advanced Light Source (ALS) at LBNL, experiments with small amounts of actinide materials are possible. Actinide investigations at the ALS are based on a graded approach to radioactive materials safety and are conducted with the assistance of LBNL Environment, Health and Safety (EH and S) personnel during the experiments. LBNL EH and S personnel have many years of experience supporting experiments utilising radioactive materials at LBNL user-based accelerator facilities. The SR techniques and technologies used in this energy region have continued to mature, permitting more complicated investigations and enabling new spectroscopic approaches. Of particular importance for work with actinides is the development of the micro-spectroscopy and spectro-microscopy capabilities on several beamlines at the ALS. These capabilities allow the use of small amounts of actinide material. In addition, these techniques can provide information on the spatial distribution of actinide species that complements the spectral information. Early demonstrations of the ability to safely collect data from actinide micro-samples and the active support of the ALS for such experiments has led to the investigations of actinide

  15. The effect of scattered light sensor orientation on roughness measurement of curved polished surfaces

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo

    2014-01-01

    Light scattering is a method for surface roughness measurements well suitable for use in a production environment thanks to its fast measurement rate, insensitivity to vibrations and to small misalignments. The method is however affected by several other factors. In this paper, the effect of angu...... of angular orientation of a commercial scattered light sensor on roughness measurements of polished cylindrical surfaces with crossed surface lay is investigated to document the robustness of the method....

  16. Light sources with different spectra affect root and mycorrhiza formation in Scots pine in vitro.

    Science.gov (United States)

    Niemi, Karoliina; Julkunen-Tiitto, Riita; Tegelberg, Riitta; Häggman, Hely

    2005-01-01

    We studied the effects of broad-spectrum light quality on the interaction between the ectomycorrhizal fungus Pisolithus tinctorius (Pers.) Coker and Couch and Scots pine (Pinus sylvestris L.) seedlings and hypocotyl cuttings cultured in vitro. The light sources were cool white (CW), warm white (WW) and red-rich daylight (RD) fluorescent lamps. Inoculation with P. tinctorius enhanced adventitious root formation of the cuttings in all light treatments. Rooting of the inoculated cuttings was highest in WW light (89%), followed by CW (73%) and RD light (66%). During 6 weeks of in vitro culture, rooted cuttings formed only a few lateral roots. The fungus grew over lateral roots, but the Hartig net was absent in all light treatments. In non-inoculated cuttings, neither root formation nor subsequent root growth was affected by light quality. In the seedling experiment, inoculation in the WW treatment resulted in a significantly (P < 0.05) greater number of lateral roots than inoculation in the RD treatment. The percentage of lateral roots covered with fungal hyphae was also highest in WW light (62%), followed by CW (50%) and RD (27%) light. A similar pattern was observed in the intensity of Hartig net formation. We conclude that effects of broad-spectrum light quality on the ectomycorrhizal fungus-root interaction are dependent on the developmental stage of the root.

  17. EFFECT OF ENERGY EFFICIENT LIGHT SOURCES ON READABILITY OF STUDENTS – AN EXPERIMENTAL APPROACH

    Directory of Open Access Journals (Sweden)

    SATHYA P.

    2016-01-01

    Full Text Available The objective of this paper is to investigate the effect of light sources on readability of students using psychophysical methods. Light sources such as Compact Fluorescent Lamp (CFL and Light Emitting Diode lamp (LED of same power rating were used in this research work because of their high lighting efficiency and uniformity of illuminance compared to that of Incandescent lamp (IL and florescent lamp (FL. A group of prospective students having normal vision, and abnormal vision like myopia, hypermetropia and astigmatism were involved in the test process. Three types of test like Snellen visual acuity, Color contrast test and Readability test were conducted on student participants under different lighting conditions. Test results showed the visibility and color contrast sensitivity of the students were high in the LED illumination. The quantitative measure of readability under different circumstances showed that the lightness difference on text under different color combination and font size, affected their readability. The computed average results confirmed that the luminance and color contrast were improved in LED illumination and also proved a high readability measure in the experimentation. Both the results of psychophysical test were proven that LED lighting was the best lighting system suitable for color distinction and readability.

  18. Preparation and characterization of B4C coatings for advanced research light sources.

    Science.gov (United States)

    Störmer, Michael; Siewert, Frank; Sinn, Harald

    2016-01-01

    X-ray optical elements are required for beam transport at the current and upcoming free-electron lasers and synchrotron sources. An X-ray mirror is a combination of a substrate and a coating. The demand for large mirrors with single layers consisting of light or heavy elements has increased during the last few decades; surface finishing technology is currently able to process mirror lengths up to 1 m with microroughness at the sub-nanometre level. Additionally, thin-film fabrication is able to deposit a suitable single-layer material, such as boron carbide (B4C), some tens of nanometres thick. After deposition, the mirror should provide excellent X-ray optical properties with respect to coating thickness errors, microroughness values and slope errors; thereby enabling the mirror to transport the X-ray beam with high reflectivity, high beam flux and an undistorted wavefront to an experimental station. At the European XFEL, the technical specifications of the future mirrors are extraordinarily challenging. The acceptable shape error of the mirrors is below 2 nm along the whole length of 1 m. At the Helmholtz-Zentrum Geesthacht (HZG), amorphous layers of boron carbide with thicknesses in the range 30-60 nm were fabricated using the HZG sputtering facility, which is able to cover areas up to 1500 mm long by 120 mm wide in one step using rectangular B4C sputtering targets. The available deposition area is suitable for the specified X-ray mirror dimensions of upcoming advanced research light sources such as the European XFEL. The coatings produced were investigated by means of X-ray reflectometry and interference microscopy. The experimental results for the B4C layers are discussed according to thickness uniformity, density, microroughness and thermal stability. The variation of layer thickness in the tangential and sagittal directions was investigated in order to estimate the achieved level of uniformity over the whole deposition area, which is considerably

  19. Efficient interfacing of light and surface plasmon polaritons for quantum optics applications

    DEFF Research Database (Denmark)

    Eran, Kot

    light and quantum emitters proves a difficult task. Current days solutions range from cavities, atomic ensembles, photonic band gaps structures, ion traps and optical latices are all being improved and studied but none has yet to emerge as superior. Recently, another proposal for such a strong coupling......The research of light and matter interactions is the most fascinating and powerful tool in advancing our understanding of both atomic and light physics. From the pioneering work of Niels Bohr in devising a model for the atom to recent research in manipulation of single atoms, light matter...... system has been put forward. By exploiting the strong confinement of light in a surface plasmon mode, a cavity-free, broadband tool can be designed to engineer the light-emitter interaction in the vicinity of metallic nano-structures. These surface plasmons, hybrid waves of light and electronic...

  20. 3D silicon breast surface mapping via structured light profilometry

    Science.gov (United States)

    Vairavan, R.; Ong, N. R.; Sauli, Z.; Kirtsaeng, S.; Sakuntasathien, S.; Shahimin, M. M.; Alcain, J. B.; Lai, S. L.; Paitong, P.; Retnasamy, V.

    2017-09-01

    Digital fringe projection technique is one of the promising optical methods for 3D surface imaging as it demonstrates non contact and non invasive characteristics. The potential of this technique matches the requirement for human body evaluation, as it is vital for disease diagnosis and for treatment option selection. Thus, the digital fringe projection has addressed this requirement with its wide clinical related application and studies. However, the application of this technique for 3D surface mapping of the breast is very minimal. Hence, in this work, the application of digital fringe projection for 3D breast surface mapping is reported. Phase shift fringe projection technique was utilized to perform the 3D breast surface mapping. Maiden results have confirmed the feasibility of using the digital fringe projection method for 3D surface mapping of the breast and it can be extended for breast cancer detection.

  1. Multiple sources of boron in urban surface waters and groundwaters.

    Science.gov (United States)

    Hasenmueller, Elizabeth A; Criss, Robert E

    2013-03-01

    Previous studies attribute abnormal boron (B) levels in streams and groundwaters to wastewater and fertilizer inputs. This study shows that municipal drinking water used for lawn irrigation contributes substantial non-point loads of B and other chemicals (S-species, Li, and Cu) to surface waters and shallow groundwaters in the St. Louis, Missouri, area. Background levels and potential B sources were characterized by analysis of lawn and street runoff, streams, rivers, springs, local rainfall, wastewater influent and effluent, and fertilizers. Urban surface waters and groundwaters are highly enriched in B (to 250μg/L) compared to background levels found in rain and pristine, carbonate-hosted streams and springs (<25μg/L), but have similar concentrations (150 to 259μg/L) compared to municipal drinking waters derived from the Missouri River. Other data including B/SO4(2-)-S and B/Li ratios confirm major contributions from this source. Moreover, sequential samples of runoff collected during storms show that B concentrations decrease with increased discharge, proving that elevated B levels are not primarily derived from combined sewer overflows (CSOs) during flooding. Instead, non-point source B exhibits complex behavior depending on land use. In urban settings B is rapidly mobilized from lawns during "first flush" events, likely representing surficial salt residues from drinking water used to irrigate lawns, and is also associated with the baseflow fraction, likely derived from the shallow groundwater reservoir that over time accumulates B from drinking water that percolates into the subsurface. The opposite occurs in small rural watersheds, where B is leached from soils by recent rainfall and covaries with the event water fraction. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Relevant factors affecting microbial surface decontamination by pulsed light.

    Science.gov (United States)

    Levy, Caroline; Aubert, Xavier; Lacour, Bernard; Carlin, Frédéric

    2012-01-16

    Pulsed Light (PL) uses intense flashes of white light rich in ultraviolet (UV) light for decontamination. A log-reduction higher than 5 was obtained in one flash and at fluences lower than 1.8J/cm(2) on spores of a range of spore-forming bacteria, of vegetative cells of non-spore-forming bacteria and on yeasts spread on agar media. Vegetative cells were more sensitive than spores. The inactivation by PL of Bacillus subtilis, B. atrophaeus, B. cereus, Geobacillus stearothermophilus, and Aspergillus niger spores sprayed on polystyrene was similar. The inactivation by PL of B. subtilis and A. niger spores sprayed on glass was slightly lower than on polystyrene. No alteration of the spore structures was detected by scanning electron microscopy for both PL treated B. subtilis and A. niger spores. The inactivation of spores of B. subtilis, B. atrophaeus, B. cereus and B. pumilus by PL or by continuous UV-C at identical fluences was not different, and was much higher by PL for A. niger spores. The increase in the input voltage of the lamps (which also increases the UV-C %) resulted in a higher inactivation. There was no correlation between the resistance to heat and the resistance to PL. The relative effect of UV-C radiations and light thermal energy on PL inactivation was discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  3. Subwavelength propagation and localization of light using surface ...

    Indian Academy of Sciences (India)

    2014-01-09

    Jan 9, 2014 ... didate to propagate and localize light at subwavelength scales. By tailoring the geometry and ... photon into plasmon waves, leading to either propagating optical fields or localized optical fields. .... Figures 5a and 5b show the transmission electron microscope (TEM) images of a sin- gle and a cluster of ...

  4. Plasma surface cleaning in a microwave plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.C.; Nelson, W.D.; Haselton, H.H.; Schechter, D.E. [Oak Ridge National Lab., TN (United States); Thompson, L.M.; Campbell, V.B.; Glover, A.L.; Googin, J.M. [Oak Ridge Y-12 Plant, TN (United States)

    1994-03-01

    A microwave electron cyclotron resonance (ECR) plasma source has been operated to produce reactive plasmas of oxygen and its mixture with argon. Aluminum samples (0.95 cm by 1.9 cm) were coated with thin films (<20 {mu}m in thickness) of Shell Vitrea oil and cleaned by using such reactive plasmas. The plasma cleaning was done in discharge conditions of microwave power up to 1300 W, radio frequency power up to 200 W, biased potential up to 400 V, gas pressures up to 5 mtorr, and operating time up to 35 min. The surface texture of the postcleaned samples has been examined visually. Mass loss of the samples after plasma cleaning was measured to estimate cleaning rates. Measured clean rates of low-pressure (0.5-mtorr) argon/oxygen plasmas were as high as 2.7 {mu}m/min. X-ray photoelectron spectroscopy (XPS) was used to determine cleanliness of the sample surfaces after plasma cleaning. The XPS study on polished samples confirmed the effectiveness of plasma cleaning in achieving atomic level of surface cleanliness. In this technical memorandum plasma properties, cleaning phenomena, and significant results are reported and discussed.

  5. RECENT BEAM MEASUREMENTS AND NEW INSTRUMENTATION AT THE ADVANCED LIGHT SOURCE

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, Fernando; Baptiste, Kenneth; Barry, Walter; Chin, Michael; Filippetto, Daniele; Jaegerhofer, Lukas; Julian, James; Kwiatkowski, Slawomir; Low, Raymond; Plate, David; Portmann, Gregory; Robin, David; Scarvie, Tomas; Stupakov, Gennady; Weber, Jonah; Zolotorev, Max

    2008-05-05

    The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years.

  6. Recent Beam Measurements and New Instrumentation at the Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Sannibale, F.; Baptiste, K.; Barry, W.; Chin, M.; /LBL, Berkeley; Filippetto, D.; /Frascati; Jaegerhofer, L.; /Vienna, Tech. U.; Julian, J.; Kwiatkowski, S.; Low, R.; Plate, D.; Portmann, G.; Robin, D.; Scarvie, T.; /LBL, Berkeley; Stupakov, G.; /SLAC; Weber, J.; Zolotorev, M.; /LBL, Berkeley

    2012-04-11

    The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years.

  7. Beam-based model of broad-band impedance of the Diamond Light Source

    Science.gov (United States)

    Smaluk, Victor; Martin, Ian; Fielder, Richard; Bartolini, Riccardo

    2015-06-01

    In an electron storage ring, the interaction between a single-bunch beam and a vacuum chamber impedance affects the beam parameters, which can be measured rather precisely. So we can develop beam-based numerical models of longitudinal and transverse impedances. At the Diamond Light Source (DLS) to get the model parameters, a set of measured data has been used including current-dependent shift of betatron tunes and synchronous phase, chromatic damping rates, and bunch lengthening. A matlab code for multiparticle tracking has been developed. The tracking results and analytical estimations are quite consistent with the measured data. Since Diamond has the shortest natural bunch length among all light sources in standard operation, the studies of collective effects with short bunches are relevant to many facilities including next generation of light sources.

  8. Beam-based model of broad-band impedance of the Diamond Light Source

    Directory of Open Access Journals (Sweden)

    Victor Smaluk

    2015-06-01

    Full Text Available In an electron storage ring, the interaction between a single-bunch beam and a vacuum chamber impedance affects the beam parameters, which can be measured rather precisely. So we can develop beam-based numerical models of longitudinal and transverse impedances. At the Diamond Light Source (DLS to get the model parameters, a set of measured data has been used including current-dependent shift of betatron tunes and synchronous phase, chromatic damping rates, and bunch lengthening. A matlab code for multiparticle tracking has been developed. The tracking results and analytical estimations are quite consistent with the measured data. Since Diamond has the shortest natural bunch length among all light sources in standard operation, the studies of collective effects with short bunches are relevant to many facilities including next generation of light sources.

  9. Microsystem light source at 488 nm for shifted excitation resonance Raman difference spectroscopy.

    Science.gov (United States)

    Maiwald, Martin; Schmidt, Heinar; Sumpf, Bernd; Güther, Reiner; Erbert, Götz; Kronfeldt, Heinz-Detlef; Tränkle, Günther

    2009-11-01

    A microsystem light source emitting at 488 nm was tested and applied as a light source for shifted excitation resonance Raman difference spectroscopy (SERRDS). A nonlinear frequency conversion using a distributed feedback (DFB) diode laser emission at 976 nm and a periodically poled lithium niobate (PPLN) waveguide crystal was realized on a micro-optical bench with a footprint of 25 mm x 5 mm. Joint temperature management via the microbench is used for wavelength tuning. Two emission lines at 487.61 nm and 487.91 nm are used for the SERRDS experiments. The Raman spectra of the test sample polystyrene demonstrate that a laser bandpass filter did not need to be implemented. Resonance Raman spectra of Tartrazine (FD&C Yellow 5, E 102) in distilled water are presented to demonstrate the suitability of this light source for SERRDS in, e.g., food safety control.

  10. Advances in broad bandwidth light sources for ultrahigh resolution optical coherence tomography

    International Nuclear Information System (INIS)

    Unterhuber, A; Povazay, B; Bizheva, K; Hermann, B; Sattmann, H; Stingl, A; Le, T; Seefeld, M; Menzel, R; Preusser, M; Budka, H; Schubert, Ch; Reitsamer, H; Ahnelt, P K; Morgan, J E; Cowey, A; Drexler, W

    2004-01-01

    Novel ultra-broad bandwidth light sources enabling unprecedented sub-2 μm axial resolution over the 400 nm-1700 nm wavelength range have been developed and evaluated with respect to their feasibility for clinical ultrahigh resolution optical coherence tomography (UHR OCT) applications. The state-of-the-art light sources described here include a compact Kerr lens mode locked Ti:sapphire laser (λ c = 785 nm, Δλ = 260 nm, P out = 50 mW) and different nonlinear fibre-based light sources with spectral bandwidths (at full width at half maximum) up to 350 nm at λ c = 1130 nm and 470 nm at λ c = 1375 nm. In vitro UHR OCT imaging is demonstrated at multiple wavelengths in human cancer cells, animal ganglion cells as well as in neuropathologic and ophthalmic biopsies in order to compare and optimize UHR OCT image contrast, resolution and penetration depth

  11. Advances in broad bandwidth light sources for ultrahigh resolution optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Unterhuber, A [Department of Medical Physics, Medical University of Vienna and Christian Doppler Laboratory, A-1090 Vienna (Austria); Povazay, B [Department of Medical Physics, Medical University of Vienna and Christian Doppler Laboratory, A-1090 Vienna (Austria); Bizheva, K [Department of Medical Physics, Medical University of Vienna and Christian Doppler Laboratory, A-1090 Vienna (Austria); Hermann, B [Department of Medical Physics, Medical University of Vienna and Christian Doppler Laboratory, A-1090 Vienna (Austria); Sattmann, H [Department of Medical Physics, Medical University of Vienna and Christian Doppler Laboratory, A-1090 Vienna (Austria); Stingl, A [Femtolasers Produktions GmbH, A-1010 Vienna (Austria); Le, T [Femtolasers Produktions GmbH, A-1010 Vienna (Austria); Seefeld, M [Institute of Physics, Dep. of Photonics, Potsdam University, D-14469 Potsdam (Germany); Menzel, R [Institute of Physics, Dep. of Photonics, Potsdam University, D-14469 Potsdam (Germany); Preusser, M [Department of Neurology, Medical University of Vienna, A-1090 Vienna (Austria); Budka, H [Department of Neurology, Medical University of Vienna, A-1090 Vienna (Austria); Schubert, Ch [Department of Physiology, Medical University of Vienna, A-1090 Vienna (Austria); Reitsamer, H [Department of Physiology, Medical University of Vienna, A-1090 Vienna (Austria); Ahnelt, P K [Department of Physiology, Medical University of Vienna, A-1090 Vienna (Austria); Morgan, J E [University Hospital of Wales Health Park, Cardiff, Wales (United Kingdom); Cowey, A [University Hospital of Wales Health Park, Cardiff, Wales (United Kingdom); Drexler, W [Department of Medical Physics, Medical University of Vienna and Christian Doppler Laboratory, A-1090 Vienna (Austria)

    2004-04-07

    Novel ultra-broad bandwidth light sources enabling unprecedented sub-2 {mu}m axial resolution over the 400 nm-1700 nm wavelength range have been developed and evaluated with respect to their feasibility for clinical ultrahigh resolution optical coherence tomography (UHR OCT) applications. The state-of-the-art light sources described here include a compact Kerr lens mode locked Ti:sapphire laser ({lambda}{sub c} = 785 nm, {delta}{lambda} = 260 nm, P{sub out} = 50 mW) and different nonlinear fibre-based light sources with spectral bandwidths (at full width at half maximum) up to 350 nm at {lambda}{sub c} = 1130 nm and 470 nm at {lambda}{sub c} = 1375 nm. In vitro UHR OCT imaging is demonstrated at multiple wavelengths in human cancer cells, animal ganglion cells as well as in neuropathologic and ophthalmic biopsies in order to compare and optimize UHR OCT image contrast, resolution and penetration depth.

  12. Consideration of a non-baked start-up of a synchrotron light source

    International Nuclear Information System (INIS)

    Hori, Y.; Kobayashi, M.

    1996-01-01

    Vacuum baking of large complex uhv devices, such as synchrotron light sources, requires both careful design and consideration of potential problems regarding the operation and maintenance of the device. Intense synchrotron irradiation can be utilized for degassing; it is indeed necessary to achieve the required operating pressure in most light sources. To examine a non-baked start-up, the outgassing of non-baked chambers by SR irradiation was measured. Also, a non-baked start-up was carried out at the Photon Factory ring. Both results demonstrate the feasibility of a non-baked start-up of a light source. The experiments and results are described, together with several other problems which must be solved for a non-baked start-up. (Author)

  13. An electronic flash lamp system to replace the traditional explosively driven light source

    Science.gov (United States)

    Stigman, William L.; Kihara, Ronald; Scarpetti, Raymond D.

    2003-07-01

    Electronic flash lamps are being developed at the Lawrence Livermore National Laboratory (LLNL). These lamps are intended to replace the traditional explosively driven Argon-gas filled light sources (Argon candles) that are currently used to provide illumination for high speed rotating mirror-framing cameras. At Livermore, we are developing an electronic flash lamp system that can match or exceed the light output of a traditional Argon candle. These systems utilize a Plasma Arc Lamp developed by PRISM Science Inc of Woburn, MA, USA. In the past, high-speed photography requiring explosively driven light sources were a one-time-only even that destroyed fixtures and optical alignment. The electronic flash lamp system, utilizing the Plasma ArC Lamp, will replace the explosively driven lighting systems and provide the capability to dry run experimental setups and repeat tests without damage to the experimental set-up. The electronic flash lamp system eliminates the problem of collateral damage to the experiment and does not add to the overall amount of explosives needed for single test. Since the Pulsed-Power driver is remotely located, only the flash lamp itself is destroyed when the explosive shot is fired. The flexible geometry of this light source also enables the user to create complex light patterns as well as photograph very large areas with a single lighting system. This electronic flash lamp system will provide an extremely bright, stable, and repeatable light source for rotating-mirror framing cameras operating at one million frames per second, using both black & white or color films. The design of the Pulsed-Power driver and the flash lamp, along with experimental data and results will be discussed.

  14. LED Light Source for in vitro Study of Photosensitizing Agents for Photodynamic Therapy

    OpenAIRE

    N.Y. Shilyagina; V.I. Plekhanov; I.V. Shkunov; P.А. Shilyagin; L.V. Dubasova; А.А. Brilkina; Е.А. Sokolova; I.V. Turchin; I.V. Balalaeva

    2014-01-01

    The aim of the investigation was to develop a LED light source providing a homogeneous light distribution in 96-well plates and allowing an independent irradiation of individual wells, as well as its experimental testing in in vitro study of photosensitizers for photodynamic therapy. Materials and Methods. The experiments were carried out on human cell lines of epidermoid carcinoma А-431 and human bladder carcinoma Т24. Two photosensitizers for fluorescence diagnostics and photodynamic th...

  15. Advances in the development of electric light sources; Fortschritte bei der Entwicklung elektrischer Lichtquellen

    Energy Technology Data Exchange (ETDEWEB)

    Serick, F. [Technische Univ. Berlin (Germany). Fachgebiet Lichttechnik

    2003-07-01

    The article gives a comprehensive survey of the basic principles of the generating of light and the technical parameters of current light sources. Developments and innovations become visible. In detail informations are given to: - special incandescent lamps with IR-reflecting bulbs - monochromatic and white LED's - low pressure discharge lamps like fluorecent lamps, compact and energy-saving lamps, lamps with inductive and capacitive power input - high pressure and super high pressure discharge lamps. (orig.)

  16. Aluminum nitride nanowire light emitting diodes: Breaking the fundamental bottleneck of deep ultraviolet light sources.

    Science.gov (United States)

    Zhao, S; Connie, A T; Dastjerdi, M H T; Kong, X H; Wang, Q; Djavid, M; Sadaf, S; Liu, X D; Shih, I; Guo, H; Mi, Z

    2015-02-16

    Despite broad interest in aluminum gallium nitride (AlGaN) optoelectronic devices for deep ultraviolet (DUV) applications, the performance of conventional Al(Ga)N planar devices drastically decays when approaching the AlN end, including low internal quantum efficiencies (IQEs) and high device operation voltages. Here we show that these challenges can be addressed by utilizing nitrogen (N) polar Al(Ga)N nanowires grown directly on Si substrate. By carefully tuning the synthesis conditions, a record IQE of 80% can be realized with N-polar AlN nanowires, which is nearly ten times higher compared to high quality planar AlN. The first 210 nm emitting AlN nanowire light emitting diodes (LEDs) were achieved, with a turn on voltage of about 6 V, which is significantly lower than the commonly observed 20 - 40 V. This can be ascribed to both efficient Mg doping by controlling the nanowire growth rate and N-polarity induced internal electrical field that favors hole injection. In the end, high performance N-polar AlGaN nanowire LEDs with emission wavelengths covering the UV-B/C bands were also demonstrated.

  17. Multiple shape light sources generated in LiNbO3 nonlinear photonic crystals with Sierpinski fractal superlattices

    Science.gov (United States)

    Ma, Boqin; Chen, Baoqin; Liu, Rongjuan; Li, Zhiyuan

    2015-08-01

    LiNbO3 nonlinear photonic crystals with two kinds of Sierpinski fractal superlattice structures, in which their domain walls are circle and square cylindrical surfaces for the second order, respectively, are successfully fabricated. Quasi-phase matching and nonlinear Čerenkov harmonics under pulse laser beams are measured. The spot- and line-shaped light sources are realized by quasi-phase matching harmonics. Ten kinds of spot-shaped outputs can be accomplished, in which the quasi-phase matching harmonic conversion efficiency for the fundamental wavelength 1.352 μm reaches 27%. A green line-shaped light source with expansion angle of about 3° is observed, which originates from the coexistence of imperfect collinear and non-collinear quasi-phase matching processes. In addition, the ring-shaped light sources of continuous wavebands from 425 nm to 675 nm are obtained by nonlinear Čerenkov harmonics. The optical properties of quasi-phase matching and Čerenkov harmonics in two kinds of crystals are highly similar to each other.

  18. A CMOS microdisplay with integrated controller utilizing improved silicon hot carrier luminescent light sources

    Science.gov (United States)

    Venter, Petrus J.; Alberts, Antonie C.; du Plessis, Monuko; Joubert, Trudi-Heleen; Goosen, Marius E.; Janse van Rensburg, Christo; Rademeyer, Pieter; Fauré, Nicolaas M.

    2013-03-01

    Microdisplay technology, the miniaturization and integration of small displays for various applications, is predominantly based on OLED and LCoS technologies. Silicon light emission from hot carrier electroluminescence has been shown to emit light visibly perceptible without the aid of any additional intensification, although the electrical to optical conversion efficiency is not as high as the technologies mentioned above. For some applications, this drawback may be traded off against the major cost advantage and superior integration opportunities offered by CMOS microdisplays using integrated silicon light sources. This work introduces an improved version of our previously published microdisplay by making use of new efficiency enhanced CMOS light emitting structures and an increased display resolution. Silicon hot carrier luminescence is often created when reverse biased pn-junctions enter the breakdown regime where impact ionization results in carrier transport across the junction. Avalanche breakdown is typically unwanted in modern CMOS processes. Design rules and process design are generally tailored to prevent breakdown, while the voltages associated with breakdown are too high to directly interact with the rest of the CMOS standard library. This work shows that it is possible to lower the operating voltage of CMOS light sources without compromising the optical output power. This results in more efficient light sources with improved interaction with other standard library components. This work proves that it is possible to create a reasonably high resolution microdisplay while integrating the active matrix controller and drivers on the same integrated circuit die without additional modifications, in a standard CMOS process.

  19. Influence of the Light Source and Curing Parameters on Microhardness of a Silorane-Based Dental Composite Material

    OpenAIRE

    Malara P.; Czech Z.; Świderski W.

    2016-01-01

    The aim of the study was to determine the influence of the light source and the light-curing parameters (the distance of the material from the light source and time of light-curing) on microhardness of Flitek Silorane dental composite material. Standardized samples of Filtek Silorane material were cured using two types of Light Curing Units (LCUs) – halogen and LED. The distance of the light source and time of curing differed between samples. The Knoop’s microhardness was tested using microha...

  20. Long-term storage life of light source modules by temperature cycling accelerated life test

    International Nuclear Information System (INIS)

    Sun Ningning; Tan Manqing; Li Ping; Jiao Jian; Guo Xiaofeng; Guo Wentao

    2014-01-01

    Light source modules are the most crucial and fragile devices that affect the life and reliability of the interferometric fiber optic gyroscope (IFOG). While the light emitting chips were stable in most cases, the module packaging proved to be less satisfactory. In long-term storage or the working environment, the ambient temperature changes constantly and thus the packaging and coupling performance of light source modules are more likely to degrade slowly due to different materials with different coefficients of thermal expansion in the bonding interface. A constant temperature accelerated life test cannot evaluate the impact of temperature variation on the performance of a module package, so the temperature cycling accelerated life test was studied. The main failure mechanism affecting light source modules is package failure due to solder fatigue failure including a fiber coupling shift, loss of cooling efficiency and thermal resistor degradation, so the Norris-Landzberg model was used to model solder fatigue life and determine the activation energy related to solder fatigue failure mechanism. By analyzing the test data, activation energy was determined and then the mean life of light source modules in different storage environments with a continuously changing temperature was simulated, which has provided direct reference data for the storage life prediction of IFOG. (semiconductor devices)

  1. Validation of in-line surface characterization by light scattering in Robot Assisted Polishing

    DEFF Research Database (Denmark)

    Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo

    2014-01-01

    sensor on the machine in a shop floor environment. Scattered light roughness measurements of the whole surfaces were performed to investigate the measurement method suitability for 100% quality control. For comparison, the surfaces were measured with reference optical instruments in laboratory conditions....... Comparison of the scattered light measurements results taken on the machine with the reference optical roughness measurements taken in laboratory demonstrate the capability of the scattered light sensor for robust in-line surface characterization. This allows for the RAP process control by proper process...

  2. Surface-Source Downhole Seismic Analysis in R

    Science.gov (United States)

    Thompson, Eric M.

    2007-01-01

    This report discusses a method for interpreting a layered slowness or velocity model from surface-source downhole seismic data originally presented by Boore (2003). I have implemented this method in the statistical computing language R (R Development Core Team, 2007), so that it is freely and easily available to researchers and practitioners that may find it useful. I originally applied an early version of these routines to seismic cone penetration test data (SCPT) to analyze the horizontal variability of shear-wave velocity within the sediments in the San Francisco Bay area (Thompson et al., 2006). A more recent version of these codes was used to analyze the influence of interface-selection and model assumptions on velocity/slowness estimates and the resulting differences in site amplification (Boore and Thompson, 2007). The R environment has many benefits for scientific and statistical computation; I have chosen R to disseminate these routines because it is versatile enough to program specialized routines, is highly interactive which aids in the analysis of data, and is freely and conveniently available to install on a wide variety of computer platforms. These scripts are useful for the interpretation of layered velocity models from surface-source downhole seismic data such as deep boreholes and SCPT data. The inputs are the travel-time data and the offset of the source at the surface. The travel-time arrivals for the P- and S-waves must already be picked from the original data. An option in the inversion is to include estimates of the standard deviation of the travel-time picks for a weighted inversion of the velocity profile. The standard deviation of each travel-time pick is defined relative to the standard deviation of the best pick in a profile and is based on the accuracy with which the travel-time measurement could be determined from the seismogram. The analysis of the travel-time data consists of two parts: the identification of layer-interfaces, and the

  3. Key components development progress updates of the 250W high power LPP-EUV light source

    Science.gov (United States)

    Yabu, Takayuki; Kawasuji, Yasufumi; Hori, Tsukasa; Okamoto, Takeshi; Tanaka, Hiroshi; Miyao, Kenichi; Ishii, Takuya; Watanabe, Yukio; Yanagida, Tatsuya; Shiraishi, Yutaka; Abe, Tamotsu; Kodama, Takeshi; Nakarai, Hiroaki; Yamazaki, Taku; Itou, Noritoshi; Saito, Takashi; Mizoguchi, Hakaru

    2017-10-01

    Gigaphoton Inc. is developing a CO2-Sn-LPP EUV light source based on unique and original technologies including a high power CO2laser with 15 nanosecond pulse duration, a solid-state pre-pulse laser with 10 picosecond pulse duration, a highly stabilized droplet generator, a precise laser-droplet shooting control system and a debris mitigation system using a magnetic field. In this paper, an update of the development progress of our 250W CO2-Sn-LPP EUV light source and of the key components is presented.

  4. Speckle noise reduction on a laser projection display via a broadband green light source.

    Science.gov (United States)

    Yu, Nan Ei; Choi, Ju Won; Kang, Heejong; Ko, Do-Kyeong; Fu, Shih-Hao; Liou, Jiun-Wei; Kung, Andy H; Choi, Hee Joo; Kim, Byoung Joo; Cha, Myoungsik; Peng, Lung-Han

    2014-02-10

    A broadband green light source was demonstrated using a tandem-poled lithium niobate (TPLN) crystal. The measured wavelength and temperature bandwidth were 6.5 nm and 100 °C, respectively, spectral bandwidth was 36 times broader than the periodically poled case. Although the conversion efficiency was smaller than in the periodic case, the TPLN device had a good figure of merit owing to the extremely large bandwidth for wavelength and temperature. The developed broadband green light source exhibited speckle noise approximately one-seventh of that in the conventional approach for a laser projection display.

  5. Drinking Water Sources with Surface Intakes from LDHH source data, Geographic NAD83, LOSCO (1999) [drinking_water_surface_intakes_LDHH_1999

    Data.gov (United States)

    Louisiana Geographic Information Center — This is a point dataset for 87 public drinking water sources with surface intakes. It was derived from a larger statewide general drinking water source dataset...

  6. Speckle-based at-wavelength metrology of x-ray optics at Diamond Light Source

    Science.gov (United States)

    Wang, Hongchang; Zhou, Tunhe; Kashyap, Yogesh; Sawhney, Kawal

    2017-08-01

    To achieve high resolution and sensitivity on the nanometer scale, further development of X-ray optics is required. Although ex-situ metrology provides valuable information about X-ray optics, the ultimate performance of X-ray optics is critically dependent on the exact nature of the working conditions. Therefore, it is equally important to perform in-situ metrology at the optics' operating wavelength (`at-wavelength' metrology) to optimize the performance of X-ray optics and correct and minimize the collective distortions of the upstream beamline optics, e.g. monochromator, windows, etc. Speckle-based technique has been implemented and further improved at Diamond Light Source. We have demonstrated that the angular sensitivity for measuring the slope error of an optical surface can reach an accuracy of two nanoradians. The recent development of the speckle-based at-wavelength metrology techniques will be presented. Representative examples of the applications of the speckle-based technique will also be given - including optimization of X-ray mirrors and characterization of compound refraction lenses. Such a high-precision metrology technique will be extremely beneficial for the manufacture and in-situ alignment/optimization of X-ray mirrors for next-generation synchrotron beamlines.

  7. Plasmon-enhanced emission from optically-doped MOS light sources.

    Science.gov (United States)

    Hryciw, Aaron; Jun, Young Chul; Brongersma, Mark L

    2009-01-05

    We evaluate the spontaneous emission rate (Purcell) enhancement for optically-doped metal-dielectric-semiconductor light-emitting structures by considering the behavior of a semiclassical oscillating point dipole placed within the dielectric layer. For a Ag-SiO(2)-Si structure containing emitters at the center of a 20-nm-thick SiO(2) layer, spontaneous emission rate enhancements of 40 to 60 can be reached in the wavelength range of 600 to 1800 nm, far away from the surface plasmon resonance; similar enhancements are also possible if Al is used instead of Ag. For dipoles contained in the thin oxide layer of a Ag-SiO(2)-Si-SiO(2) structure, the emission exhibits strong preferential coupling to a single well-defined Si waveguide mode. This work suggests a means of designing a new class of power-efficient, high-modulation-speed, CMOS-compatible optical sources that take full advantage of the excellent electrical properties and plasmon-enhanced op cal properties afforded by MOS devices.

  8. Surface and pulpal temperature comparison of tooth whitening using lasers and curing lights

    Science.gov (United States)

    White, Joel M.; Pelino, Jose; Rodrigues, Rively; Zwhalen, Brian J.; Nguyen, Max H.; Wu, Emily

    2000-03-01

    Chemical action of bleaching agents applied to tooth surface is accelerated by increase in temperature. This in vitro study measured the temperature rises on the surface and in the pulp of teeth during whitening using a diode laser, a plasma arc curing (PAC) light and conventional curing lights. Extracted, non-carious single-rooted teeth were exposed to PAC light and laser at times ranging from 10 to 60 seconds and energy ranges of 2 W, 4 W, and 6 W, and to low-intensity curing lights from 1 to 4 minutes. Maximum temperature rises were analyzed for both pulpal and surface temperature. Diode laser exposures at 2 W for all times and at 4 watts for 10 seconds and PAC light exposures at 10 seconds all produced acceptably safe pulpal rises equivalent to conventional light-curing exposures. Exposures at these settings also attained surface temperature rises that were significantly higher than those using conventional light-curing. The diode laser demonstrated bleaching results equivalent to the PAC light, and both were achieved in significantly less times than conventional light- curing.

  9. Biological stimulation of the Human skin applying health promoting light and plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Awakowicz, P.; Bibinov, N. [Center for Plasma Science and Technology, Ruhr-University, Bochum (Germany); Born, M.; Niemann, U. [Philips Research, Aachen (Germany); Busse, B. [Zell-Kontakt GmbH, Noerten-Hardenberg (Germany); Gesche, R.; Kuehn, S.; Porteanu, H.E. [Ferdinand-Braun-Institut fuer Hoechstfrequenztechnik, Berlin (Germany); Helmke, A. [University of Applied Sciences and Arts, Goettingen (Germany); Kaemling, A.; Wandke, D. [CINOGY GmbH, Duderstadt (Germany); Kolb-Bachofen, V.; Liebmann, J. [Institute for Immunobiology, Heinrich-Heine University, Duesseldorf (Germany); Kovacs, R.; Mertens, N.; Scherer, J. [Aurion Anlagentechnik GmbH, Seligenstadt (Germany); Oplaender, C.; Suschek, C. [Clinic for Plastic Surgery, University Clinic, Aachen (Germany); Vioel, W. [Laser-Laboratorium, Goettingen (Germany); University of Applied Sciences and Arts, Goettingen (Germany)

    2009-10-15

    In the frame of BMBF project ''BioLiP'', new physical treatment techniques aiming at medical treatment of the human skin have been developed. The acronym BioLiP stands for ''Desinfektion, Entkeimung und biologische Stimulation der Haut durch gesundheitsfoerdernde Licht- und Plasmaquellen'' (Disinfection, germ reduction and biological stimulation of the human skin by health promoting light and plasma sources). A source applying a low-temperature dielectric barrier discharge plasma (DBD) has been investigated on its effectiveness for skin disinfection and stimulation of biological material. Alternatively an atmospheric plasma source consisting of a microwave resonator combined with a solid state power oscillator has been examined. This concept which allows for a compact and efficient design avoiding external microwave power supply and matching units has been optimized with respect to nitrogen monoxide (NO) production in high yields. In both cases various application possibilities in the medical and biological domain are opened up. Light sources in the visible spectral range have been investigated with respect to the proliferation of human cell types. Intensive highly selective blue light sources based on LED technology can slow down proliferation rates without inducing toxic effects which offers new opportunities for treatments of so-called hyperproliferative skin conditions (e.g. with psoriasis or in wound healing) using UV-free light. (copyright 2009 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. Synchrotron light sources and free-electron lasers accelerator physics, instrumentation and science applications

    CERN Document Server

    Khan, Shaukat; Schneider, Jochen; Hastings, Jerome

    2016-01-01

    Hardly any other discovery of the nineteenth century did have such an impact on science and technology as Wilhelm Conrad Röntgen’s seminal find of the X-rays. X-ray tubes soon made their way as excellent instruments for numerous applications in medicine, biology, materials science and testing, chemistry and public security. Developing new radiation sources with higher brilliance and much extended spectral range resulted in stunning developments like the electron synchrotron and electron storage ring and the freeelectron laser. This handbook highlights these developments in fifty chapters. The reader is given not only an inside view of exciting science areas but also of design concepts for the most advanced light sources. The theory of synchrotron radiation and of the freeelectron laser, design examples and the technology basis are presented. The handbook presents advanced concepts like seeding and harmonic generation, the booming field of Terahertz radiation sources and upcoming brilliant light sources dri...

  11. Numerical calculation of the geometric efficiency of circular detector and surface source arrangements

    International Nuclear Information System (INIS)

    Wilson, O.J.

    1980-05-01

    This report describes a numerical technique of determining the geometric efficiency of circular detector and various surface source arrangements. Circular sources are primarily discussed, but most other surface shapes can be accommodated by the technique

  12. Soft X-ray optics for spectromicroscopy at the Advanced Light Source

    International Nuclear Information System (INIS)

    Padmore, H.A.

    1997-01-01

    A variety of systems for performing spectromicroscopy, spatially resolved spectroscopy, are in operation or under construction at the Advanced Light Source (ALS). For example, part of our program is centered around the surface analysis problems of local semiconductor industries, and this has required the construction of a microscope with wafer handling, fiducialization, optical microscopy, coordinated ion beam etching, and X-ray Photoelectron Spectroscopy (XPS) integrated in this case with Kirkpatrick-Baez (K-B) grazing incidence micro-focusing optics. The microscope is to be used in conjunction with a highly efficient entrance slitless Spherical Grating Monochromator (SGM). The design and expected performance of this instrument will be described, with emphasis on the production of the elliptically curved surfaces of the K-B mirrors by elastic bending of flat mirror substrates. For higher resolution, zone-plate (Z-P) focusing optics are used and one instrument, a Scanning Transmission X-ray Microscope (STXM) is in routine operation on undulator beamline 7.0. A second Z-P based system is being commissioned on the same beamline, and differs from the STXM in that it will operate at Ultra-High Vacuum (UHV) and will be able to perform XPS at 0.1 μm spatial resolution. Spatially resolved X-ray Absorption Spectroscopy (XAS) can be performed by imaging electrons photoemitted from a material with a Photo-Emission Electron Microscope (PEEM). The optical requirements of a beamline designed for PEEM are very different to those of micro-focus systems and we give examples of bending magnet and undulator based instruments. copyright 1997 American Institute of Physics

  13. Soft x-ray optics for spectromicroscopy at the Advanced Light Source

    International Nuclear Information System (INIS)

    Padmore, H.A.

    1996-09-01

    A variety of systems for performing spectromicroscopy, spatially resolved spectroscopy, are in operation or under construction at the Advanced Light Source (ALS). For example, part of the program is centered around the surface analysis problems of local semiconductor industries, and this has required the construction of a microscope with wafer handling, fiducialization, optical microscopy, coordinated ion beam etching, and X-ray Photoelectron Spectroscopy (XPS) integrated in this case with Kirkpatrick-Baez (K-B) grazing incidence micro-focusing optics. The microscope is to be used in conjunction with a highly efficient entrance slitless Spherical Grating Monochromator (SGM). The design and expected performance of this instrument will be described, with emphasis on the production of the elliptically curved surfaces of the K-B mirrors by elastic bending of flat mirror substrates. For higher resolution, zone-plate (Z-P) focusing optics are used and one instrument, a Scanning Transmission X-ray Microscope (STXM) is in routine operation on undulator beamline 7.0. A second Z-P based system is being commissioned on the same beamline, and differs from the STXM in that it will operate at Ultra-High Vacuum (UHV) and will be able to perform XPS at 0.1 microm spatial resolution. Spatially resolved X-ray Absorption Spectroscopy (XAS) can be performed by imaging electrons photoemitted from a material with a Photo-Emission Electron Microscope (PEEM). The optical requirements of a beamline designed for PEEM are very different to those of micro-focus systems and they give examples of bending magnet and undulator based instruments

  14. The study of LED light source illumination conditions for ideal algae cultivation

    Science.gov (United States)

    Tsai, Chun-Chin; Huang, Chien-Fu; Chen, Cin-Fu; Yue, Cheng-Feng

    2017-02-01

    Utilizing LED light source modules with 3 different RGB colors, the illumination effect of different wavelengths had been investigated on the growth curve of the same kind of micro algae. It was found that the best micro algae culturing status came out with long wavelength light such as red light (650 670 nm). Based on the same condition for a period of 3 weeks , the grown micro algae population density ratio represented by Optical Density (O.D.) ratio is 1?0.4?0.7 corresponding to growth with Red, Green, Blue light sources, respectively. Mixing 3 types and 2 types of LEDs with different parameters, the grown micro algae population densities were compared in terms of O.D. Interestingly enough, different light sources resulted in significant discoloration on micro algae growth, appearing yellow, brown, green, etc. Our experiments results showed such discoloration effect is reversible. Based on the same lighting condition, micro algae growth can be also affected by incubator size, nutrition supply, and temperature variation. In recent years, micro algae related technologies have been international wise a hot topic of energy and environmental protection for research and development institutes, and big energy companies among those developed countries. There will be an economically prosperous future. From this study of LED lighting to ideal algae cultivation, it was found that such built system would be capable of optimizing artificial cultivation system, leading to economic benefits for its continuous development. Since global warming causing weather change, accompanying with reducing energy sources and agriculture growth shortage are all threatening human being survival.

  15. Suppressing light reflection from polycrystalline silicon thin films through surface texturing and silver nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Akhter, Perveen [Department of Physics, University at Albany-SUNY, Albany, New York 12222 (United States); Huang, Mengbing, E-mail: mhuang@albany.edu; Kadakia, Nirag; Spratt, William; Malladi, Girish; Bakhru, Hassarum [SUNY College of Nanoscale Science and Engineering, Albany, New York 12203 (United States)

    2014-09-21

    This work demonstrates a novel method combining ion implantation and silver nanostructures for suppressing light reflection from polycrystalline silicon thin films. Samples were implanted with 20-keV hydrogen ions to a dose of 10¹⁷/cm², and some of them received an additional argon ion implant to a dose of 5×10¹⁵ /cm² at an energy between 30 and 300 keV. Compared to the case with a single H implant, the processing involved both H and Ar implants and post-implantation annealing has created a much higher degree of surface texturing, leading to a more dramatic reduction of light reflection from polycrystalline Si films over a broadband range between 300 and 1200 nm, e.g., optical reflection from the air/Si interface in the AM1.5 sunlight condition decreasing from ~30% with an untextured surface to below 5% for a highly textured surface after post-implantation annealing at 1000°C. Formation of Ag nanostructures on these ion beam processed surfaces further reduces light reflection, and surface texturing is expected to have the benefit of diminishing light absorption losses within large-size (>100 nm) Ag nanoparticles, yielding an increased light trapping efficiency within Si as opposed to the case with Ag nanostructures on a smooth surface. A discussion of the effects of surface textures and Ag nanoparticles on light trapping within Si thin films is also presented with the aid of computer simulations.

  16. Light sources and culture media in the in vitro growth of the Brazilian orchid Microlaelia lundii

    Directory of Open Access Journals (Sweden)

    Vanessa Favetta

    2017-08-01

    Full Text Available The Brazilian micro-orchid Microlaelia lundii enchants by its beautiful blooms in winter, but its cultivation is still a challenge, requiring specific care. The objectiv of this work was to evaluate the influence of light sources and culture media on in vitro growth and ex vitro survival of this micro-orchid. M. lundii seedlings were transferred to flasks containing the culture medium ½ MS and Simplified Medium, consisting of 5 mL L-1 of Biofert Plus® NPK fertilizer (09-08-09 and 60 g L-1 of ‘Nanica’ banana pulp. These flasks were placed in a growth chamber composed of seven environments, characterized by types of lighting: L1 LEDtube 4000K; L2 LEDtube 6500K; L3 L1 + L2; L4 L1 + L1; L5 red LED; L6 blue LED; L7 fluorescent lamp (control. After 200 days of cultivation, biometric growth parameters and leaves chlorophyll content were evaluated together with the percentage of seedling survival when acclimatized. At the end of the experiment, an analysis of individual variances and a combined analysis of the environments were carried out. The simplified medium led to higher seedlings, especially for light source L6. Light sources L1, L2, L3 and L4 promoted an increase in the seedlings root system in the simplified medium. As for the chlorophyll content, L4 and L7 showed higher contents of chlorophyll a and b. The simplified medium led practically to 100% of seedling survival, regardless of the light source used. Results shown that the simplified medium for light sources L1, L2, L3 and L4 is recommended for the in vitro propagation of M. lundii.

  17. Compact linac-driven light sources utilizing mm-period RF undulators

    Science.gov (United States)

    Toufexis, F.; Dolgashev, V. A.; Limborg-Deprey, C.; Tantawi, S. G.

    2017-08-01

    Conventional synchrotron light sources and Free-Electron Lasers (FELs) utilize permanent magnet undulators with periods on the order of a few centimeters, and to generate X-rays they need GeV scale electron beam energies. Such facilities are very large and expensive. Inverse Compton scattering sources use a laser beam as an undulator with micrometer periods and produce X-ray energies on the order of tens of keV. These sources operate with MeV scale beam energies, and therefore they are much more compact. However, their average photon flux is typically small, especially in the EUV and soft X-ray regime. We present a novel compact linac-driven light source, which could produce both incoherent and FEL radiation depending on its configuration. This source is based on a mm-period RF undulator. The RF undulator is a mm-wave cavity resonating at a deflecting mode. The source operates as follows: a train of electron bunches is generated in a thermionic X-band RF injector. These bunches are accelerated in an X-band linac and then interact with the RF undulator. The RF power that feeds the undulator is extracted from the electron beam in a decelerating RF structure, located downstream of the undulator. As an example, a light source with a 91.392 GHz RF undulator and a 129 MeV electron beam can generate incoherent EUV radiation at 13.5 nm. Such a light source could be less than 6 m long, and potentially be used for EUV mask metrology. Similar approach will enable soft X-Ray imaging.

  18. Exciting Graphene Surface Plasmon Polaritons through Light and Sound Interplay

    KAUST Repository

    Farhat, Mohamed

    2013-12-05

    We propose a concept that allows for efficient excitation of surface plasmon spolaritons (SPPs) on a thin graphene sheet located on a substrate by an incident electromagnetic field. Elastic vibrations of the sheet, which are generated by a flexural wave, act as a grating that enables the electromagnetic field to couple to propagating graphene SPPs. This scheme permits fast on-off switching of the SPPs and dynamic tuning of their excitation frequency by adjusting the vibration frequency (grating period). Potential applications include single molecule detection and enhanced control of SPP trajectories via surface wave patterning of graphene metasurfaces. Analytical calculations and numerical experiments demonstrate the practical applicability of the proposed concept.

  19. Shedding light on surface-assembled photosynthetic systems

    NARCIS (Netherlands)

    Magis, Johan Gerhard

    2012-01-01

    The interfacing of biomolecules to nanostructures, electrode surfaces and/or optical components constitutes the new discipline of bioelectronics. It is based on electron transfer between a protein and an electrode, and can be monitored by amperometric techniques. The integration of biomolecules with

  20. Laser-induced periodic surface structures: fingerprints of light localization

    NARCIS (Netherlands)

    Skolski, J.Z.P.; Römer, G.R.B.E.; Obona, J.V.; Ocelik, V.; Huis in 't Veld, A.J.; Hosson, J.Th.M. de

    2012-01-01

    The finite-difference time-domain (FDTD) method is used to study the inhomogeneous absorption of linearly polarized laser radiation below a rough surface. The results are first analyzed in the frequency domain and compared to the efficacy factor theory of Sipe and coworkers. Both approaches show