  1. Supply air filters after the nuclear reactor accident at Chernobyl

    International Nuclear Information System (INIS)

    Bonka, H.

    1989-01-01

    In the case of increased activity concentration in the air supply air filters are the facility compounds where enhanced activity is collected. Therefore, it was understandable that the people put questions about the doses caused by supply air filters after the nuclear reactor accident at Chernobyl. When comparing the local dose rate at a distance of 1 m in front of filters with the outdoor local dose rate due to dry deposited radionuclides, nearly the same local dose rate results assuming an air flow rate of approx. 60 m 3 /h. Supposing a 10 hours stay at a distance of 1 m in front of filters and an air flow rate of approx. 5000 m 3 /h the same dose is obtained after a 10 days delay as the dose due to outdoor inhalation. At Aachen, the local dose rate near to filters increased up to approx. 10 μSv/h. After a suitable time delay of one month filters could be rejected like normal waste. A review is given on individual measured values

  2. The performance and subjective responses of call-center operators with new and used supply air filters at two outdoor air supply rates

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Wyon, David; Fanger, Povl Ole

    2004-01-01

    A 2X2 replicated field intervention experiment was conducted in a call-center providing a telephone directory service: outdoor air supply rate was adjusted to be 8% of the total airflow of 430 l/s (3.5/h)and the supply air filters were either new or had been in place for 6 months. One of these in......A 2X2 replicated field intervention experiment was conducted in a call-center providing a telephone directory service: outdoor air supply rate was adjusted to be 8% of the total airflow of 430 l/s (3.5/h)and the supply air filters were either new or had been in place for 6 months. One...

  3. Call-centre occupant response to new and used filters at two outdoor air supply rates

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Wyon, David; Nielsen, J.

    2002-01-01

    A 2x2 replicaterd field intervention experiment was conducted in a call-centre providing a public telephone directory service: outdoor air supply rate was 8% or 80% of the total airflow of 430 L/s providing 3.5 h-1; and the supply air filters were either new or used (i.e. used in place for 6 mont......). Each of these 4 conditions was maintained for a full working week at a time. Room temperature and humidity averaged 24 deg.C and 27% RH. The 26 operators were blind to conditions and assessed perceived air quality (PAQ), the intensity of Sick Building Syndrome (SBS) symnptoms and self...

  4. Experiment on a multilayer type air filter for the filtration of sodium aerosol

    International Nuclear Information System (INIS)

    Otake, N.; Nozaki, O.

    1987-01-01

    An emergency air filter system of FBR was developed by using a multilayer type filter to protect the function of HEPA filter from clogging due to loading of sodium aerosol. To examine the effect of loading of sodium aerosol on the filter system, sodium aerosol consisting of sodium oxides and the related compound was supplied to the filter system. Several parameters to determine the effectiveness of the multilayer type filter were surveyed. It was confirmed that the emergency air filter system of FBR consisting of the multilayer type filter, a medium filter, HEPA filter with standard size (610 mm x 610 mm) in series could hold 800 g-Na at 1.5 kPa without clogging

  5. Controls of nitrite oxidation in ammonia-removing biological air filters

    DEFF Research Database (Denmark)

    Juhler, Susanne; Ottosen, Lars Ditlev Mørck; Nielsen, Lars Peter

    2008-01-01

    in accumulation of nitrate rather than nitrite and a significant decline in pH. As a consequence, ammonia is removed more efficiently, but heterotrophic oxidation of odorous compounds might be inhibited.  To identify the controlling mechanisms of nitrite oxidation, full-scale biological air filters were...... activity resulting in a lowered pH and thus a decreased FA concentration, promoting further growth of NOB. Yet, in some cases a situation with a nitrate-to-nitrite ratio of 1 and moderate pH remained stable even under varying air load and water supply, suggesting that additional mechanisms were involved......In biological air filters ammonia is removed due to the action of Ammonia Oxidizing Bacteria (AOB) resulting in nitrite accumulation exceeding 100 mM. Among filters treating exhaust air from pig facilities successful establishment of Nitrite Oxidizing Bacteria (NOB) sometimes occurs, resulting...

  6. Recirculating electric air filter

    Science.gov (United States)

    Bergman, W.

    1985-01-09

    An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  7. Cost/benefit evaluation of electrofibrous air filters

    International Nuclear Information System (INIS)

    Bergman, W.; Kuhl, W.; Biermann, A.; Lum, B.

    1986-01-01

    Experimental electric air filters based on the principle of superimposing an electric field over conventional fibrous air filters have been developed. The different experimental electric filters described in this report include prefilters for use in glove boxes and in ventilation systems, re-circulating air filters, electric HEPA filters, and high efficiency, high temperature air filters. In each case the large improvement in filter efficiency that occurs when a mechanical filter is electrified is demonstrated. Also a significant increase in the particle loading capacity of filters in many of our evaluations is demonstrated. Both laboratory and field test results are presented. This paper also demonstrates that the performance of all of our electric filter designs, except one, can be matched by conventional mechanical air filters and usually at a lower cost. The one exception is the high temperature, high efficiency electric air filter. In that case there is no mechanical filter media that can match the performance of the electric air filter. Our findings show that electric air filters are only cost effective compared to mechanical air filters when the performance of the mechanical air filter cannot be further improved by mechanical means. (author)

  8. Effects of filter housing and ductwork configuration on air flow uniformity inside air cleaning filter housings

    International Nuclear Information System (INIS)

    Paul, J.D.

    1993-01-01

    Each new HEPA filter installation presents a different physical configuration based on the system requirements, the available space and designer preference. Each different configuration can result in variations of air flow uniformity inside the filter housing across the filter banks. This paper presents the results of air flow uniformity testing for six different filter housing/ductwork configurations and discusses if any of those variations in air flow uniformity is attributable to the difference in the physical arrangements for the six cases

  9. The effects of electrostatic particle filtration and supply-air filter condition in classrooms on the performance of schoolwork by children (RP-1257)

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Wyon, David Peter; Jensen, Kasper Lynge

    2008-01-01

    the lower the outdoor air supply rate. There were no consistent effects of this reduction on the performance of schoolwork, on the children's perception of the classroom environment, on symptom intensiiy, or on air quality as perceived by the sensory panel. This suggests there are no short-term (acute...... the filters in use in other schools were not changed. The conditions were established for one week at a time in a blind crossover design with repeated measures on ten-to-twelve-year-old children. Pupils performed six exercises exemplifying different aspects of schoolwork as part of normal lessons...... and indicated their environmental perceptions and the intensity of any symptoms. A sensory panel of adults judged the air quality in the classrooms soon after the pupils left. Operating the electrostatic air cleaners considerably reduced the concentration of particles in the classrooms. The effect was greater...

  10. The effect of air supply on nitrogen removal using a biological filter ...

    African Journals Online (AJOL)

    2009-10-02

    Oct 2, 2009 ... 0.04 m3∙m−2∙d−1) (Fig. 2). Air was supplied by means of a compressor (Model: Fini, ... effluent from a domestic wastewater treatment plant (COD was approx. .... The resultant ammonium was determined as men- tioned before ...

  11. HEPA air filter (image)

    Science.gov (United States)

    ... pet dander and other irritating allergens from the air. Along with other methods to reduce allergens, such ... controlling the amount of allergens circulating in the air. HEPA filters can be found in most air ...

  12. Air filters for use at nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Linder, P [Aktiebolaget Atomenergi, Studsvik, Nykoeping (Sweden)

    1970-12-01

    The ventilation system of a nuclear facility plays a vital role in ensuring that the air in working areas and the environment remains free from radioactive contamination. An earlier IAEA publication, Techniques for Controlling Air Pollution from the Operation of Nuclear Facilities, Safety Series No. 17, deals with the design and operation of ventilation systems at nuclear facilities. These systems are usually provided with air-cleaning devices which remove the contaminants from the air. This publication is intended as a guide to those who are concerned with the design of air-filtering systems and with the testing, operation and maintenance of air-filter installations at nuclear facilities. Emphasis is mainly placed on so-called high-efficiency particulate air filters (HEPA filters) and on providing general information on them. Besides describing the usual filter types, their dimensions and construction materials, the guidebook attempts to explain their properties and behaviour under different operating conditions. It also gives advice on testing and handling the filters so that effective and safe performance is ensured. The guidebook should serve as an introduction to the use of high efficiency particulate air filters in countries where work with radioactive materials has only recently commenced. The list of references at the end of the book indicates sources of more advanced information for those who already have comprehensive experience in this field. It is assumed here that the filters are obtained from a manufacturer, and the guidebook thus contains no information on the design and development of the filter itself, nor does it deal with the cleaning of the intake air to a plant, with gas sorption or protective respiratory equipment.

  13. Air filters for use at nuclear facilities

    International Nuclear Information System (INIS)

    Linder, P.

    1970-01-01

    The ventilation system of a nuclear facility plays a vital role in ensuring that the air in working areas and the environment remains free from radioactive contamination. An earlier IAEA publication, Techniques for Controlling Air Pollution from the Operation of Nuclear Facilities, Safety Series No. 17, deals with the design and operation of ventilation systems at nuclear facilities. These systems are usually provided with air-cleaning devices which remove the contaminants from the air. This publication is intended as a guide to those who are concerned with the design of air-filtering systems and with the testing, operation and maintenance of air-filter installations at nuclear facilities. Emphasis is mainly placed on so-called high-efficiency particulate air filters (HEPA filters) and on providing general information on them. Besides describing the usual filter types, their dimensions and construction materials, the guidebook attempts to explain their properties and behaviour under different operating conditions. It also gives advice on testing and handling the filters so that effective and safe performance is ensured. The guidebook should serve as an introduction to the use of high efficiency particulate air filters in countries where work with radioactive materials has only recently commenced. The list of references at the end of the book indicates sources of more advanced information for those who already have comprehensive experience in this field. It is assumed here that the filters are obtained from a manufacturer, and the guidebook thus contains no information on the design and development of the filter itself, nor does it deal with the cleaning of the intake air to a plant, with gas sorption or protective respiratory equipment

  14. Retention of fission products in air filters

    International Nuclear Information System (INIS)

    Sobnack, R.

    1986-01-01

    The plume from the Chernobyl nuclear reactor reached London in the morning of 1st May. Less than two weeks later, the Physics Department, University of Surrey, reported a measurable level of radioactivity in air filters. On 15th May air filters from within the air conditioning plant of the Radioisotope Department at the London Hospital were removed for radiation checks. Crude tests with a geiger counter gave readings of 5-10 times higher than background levels. Gamma-ray spectroscopy of the departmental air filters (AF1) using a 127 mm NaI detector revealed a pattern characteristic of emissions of fission products from a nuclear reactor. Another air filter (AF2), from the home of a member of staff, was much less active. Because of the complexity of the gamma-ray spectrum and the relatively high level of emission from the departmental air filter, a thorough investigation was carried out using a high purity germanium detector. (author)

  15. Development and evaluation of a plant-based air filter system for ...

    African Journals Online (AJOL)

    Y. Choi

    2013-04-17

    Apr 17, 2013 ... plant based filter system on bacterial growth in aqueous media, the compressed air was fed to the system at a rate of 200 mL/min, and the exhaust gas from the system was supplied to a bacterial culture. In this experiment, we attempted to verify the inhibition activity of the gas on bacterial growth in aqueous ...

  16. The ''Nuclear-Karlsruhe'' air-filter system

    International Nuclear Information System (INIS)

    Berliner, P.; Ohlmeyer, M.; Stotz, W.

    1976-01-01

    Increasing requirements for exhaust-air filter systems used in nuclear facilities induced the Gesellschaft fuer Kernforschung to develop the ''Nuclear-Karlsruhe'' HEPA filter system. This novel development has profited by experience gained in previous incidents as well as by maitenance and decontamination work performed with different HEPA filter systems. The proved ''Nuclear-Karlsruhe'' system takes equally into account the demands for optimum safety, maximum efficiency and economy, and is distinguished by the following features: (1) The air current is defected by 180 0 in the casing. Deflection causes quite a number of improvements, results in substantial reduction of space requirements, and avoids the dispersion of pollutants to the clean-air side. Besides, the HEPA filter is protected from damage by condensed particles or foreign materials entrained; (2) The ''Nuclear-Karlsruhe'' system allows gas-tight filter replacement. Special replacement collars have been provided at the casing, which allow the tight fastening of replacement bags which are self-locking. (3) In-place testing in the operating condition can be carried out very conveniently because the air is deflected. Minimum leaks in the filter medium or in the filter gasket can be detected by the high-sensitivity visual oil-thread test, which makes leaks distinctly visible as oil mist threads through a transparent front window provided on the clean-air side. The test takes only some minutes and its sensitivity is hardly matched by any other technique. (4) The clamping mechanism is installed outside the casing, i.e. outside the polluted or aggressive media. The contact force is spring-loaded absolutely uniformly to the circular filter gasket. (5) For practical and econmic reasons the filter casings can be locked individually so as to be gas-tight. (6) The entire system is made of stainless or coated steel and metal parts which are corrosion and fire-resistant. (author)

  17. Enhancing indoor air quality -The air filter advantage.

    Science.gov (United States)

    Vijayan, Vannan Kandi; Paramesh, Haralappa; Salvi, Sundeep Santosh; Dalal, Alpa Anil Kumar

    2015-01-01

    Air pollution has become the world's single biggest environmental health risk, linked to around 7 million deaths in 2012 according to a recent World Health Organisation (WHO) report. The new data further reveals a stronger link between, indoor and outdoor air pollution exposure and cardiovascular diseases, such as strokes and ischemic heart disease, as well as between air pollution and cancer. The role of air pollution in the development of respiratory diseases, including acute respiratory infections and chronic obstructive pulmonary diseases, is well known. While both indoor and outdoor pollution affect health, recent statistics on the impact of household indoor pollutants (HAP) is alarming. The WHO factsheet on HAP and health states that 3.8 million premature deaths annually - including stroke, ischemic heart disease, chronic obstructive pulmonary disease (COPD) and lung cancer are attributed to exposure to household air pollution. Use of air cleaners and filters are one of the suggested strategies to improve indoor air quality. This review discusses the impact of air pollutants with special focus on indoor air pollutants and the benefits of air filters in improving indoor air quality.

  18. Ventilation filters as sources of air pollution – Processes occurring on surfaces of used filters

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Halás, Oto; Clausen, Geo

    2004-01-01

    Ozone concentrations were monitored upstream and downstream of used filter samples following 24hours of ventilation with ozone- filtered air. The ozone concentration in the air upstream of the filters was maintained at ~75 ppb while the concentration downstream of the filters was initially betwee...

  19. Suggestions for removing operational faults in air filter plants

    Energy Technology Data Exchange (ETDEWEB)

    Ochs, H J

    1980-11-01

    Air filters are expected to achieve certain performances within their duty, viz. to precipitate air-alien matter in the air stream, the results of which will have to be checked. As a number of external influences affect the function of the air filter and, therefore, may alter the pre-defined data, checking should not only cover the air filter but also the other parts of the ventilating plant, to assure a faultless continuous operation.

  20. Leak test method and test device for iodine filter

    International Nuclear Information System (INIS)

    Fukasawa, Tetsuo; Funabashi, Kiyomi; Miura, Noboru; Miura, Eiichi.

    1995-01-01

    An air introduction device which can change a humidity is disposed upstream of an iodine filter to be tested, and a humidity measuring device is disposed downstream of the iodine filter respectively. At first, dried air reduced with humidity is flown from the air introduction device to the iodine filter, to remove moisture content from an iodine adsorber in the iodine filter. Next, air at an increased humidity is supplied to the iodine filter. The difference between the time starting the supply of the highly humid air and the time detecting the high humidity at the humidity measuring device is measured. When the time difference is smaller than the time difference measured previously in a normal iodine filter, it shows the presence of leak in the iodine filter to be tested. With such procedures, leakage in the iodine filter which removes radioactive iodine from off-gases discharged from the radioactive material handling facilities can be detected easily by using water (steams), namely, a naturally present material. (I.N.)

  1. Transistor-based filter for inhibiting load noise from entering a power supply

    Science.gov (United States)

    Taubman, Matthew S

    2013-07-02

    A transistor-based filter for inhibiting load noise from entering a power supply is disclosed. The filter includes a first transistor having an emitter coupled to a power supply, a collector coupled to a load, and a base. The filter also includes a first capacitor coupled between the base of the first transistor and a ground terminal. The filter further includes an impedance coupled between the base and a node between the collector and the load, or a second transistor and second capacitor. The impedance can be a resistor or an inductor.

  2. Sensory source strength of used ventilation filters

    DEFF Research Database (Denmark)

    Clausen, Geo; Alm, Ole Martin; Fanger, Povl Ole

    2002-01-01

    A two-year-old filter was placed in a ventilation system recirculating the air in an experimental space. Via glass tubes supplied with a small fan it was possible to extract air upstream and downstream of the filter to an adjacent room. A panel could thus perform sensory assessments of the air fr...

  3. Air-conditioner filters enriching dust mites allergen.

    Science.gov (United States)

    Zhan, Xiaodong; Li, Chaopin; Xu, Haifeng; Xu, Pengfei; Zhu, Haibin; Diao, Jidong; Li, Na; Zhao, Beibei

    2015-01-01

    We detected the concentration of dust mites allergen (Der f1 & Der p1) in the air of different places before and after the starting of air-conditioners in Wuhu City, Anhui, China, and to discuss the relation between the dust mites allergen in air-conditioner filters and the asthma attack. The dust samples were collected from the air-conditioner filters in dining rooms, shopping malls, hotels and households respectively. Concentrations of dust mites major group allergen 1 (Der f 1, Der p1) were detected with enzyme linked immunosorbent assay (ELISA), and the dust mite immune activities were determined by dot-ELISA. The concentration of Der f1 in dining rooms, shopping malls, hotels and households was 1.52 μg/g, 1.24 μg/g, 1.31 μg/g and 1.46 μg/g respectively, and the concentration of Der p1 in above-mentioned places was 1.23 μg/g, 1.12 μg/g, 1.16 μg/g and 1.18 μg/g respectively. The concentration of Der f1 & Der p1 in air was higher after the air-conditioners starting one hours later, and the difference was significant (Pair-conditioner filters can enrich dust mites major group allergen, and the allergens can induce asthma. The air-conditioner filters shall be cleaned or replaced regularly to prevent or reduce accumulation of the dust mites and its allergens.

  4. Effectiveness of photocatalytic filter for removing volatile organic compounds in the heating, ventilation, and air conditioning system.

    Science.gov (United States)

    Yu, Kuo-Pin; Lee, Grace Whei-May; Huang, Wei-Ming; Wu, Chih-Cheng; Lou, Chia-ling; Yang, Shinhao

    2006-05-01

    Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photocatalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr(-1), and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and formaldehyde found in this study ranged from 0.381 to 1.01 hr(-1) under different total air change rates, from 0.34 to 0.433 hr(-1) under different RH, and from 0.381 to 0.433 hr(-1) for different photocatalytic filters.

  5. High efficiency steel filters for nuclear air cleaning

    International Nuclear Information System (INIS)

    Bergman, W.; Conner, J.; Larsen, G.; Lopez, R.; Turner, C.; Vahla, G.; Violet, C.; Williams, K.

    1991-01-01

    The authors have, in cooperation with industry, developed high-efficiency filters made from sintered stainless-steel fibers for use in several air-cleaning applications in the nuclear industry. These filters were developed to overcome the failure modes in present high-efficiently particulate air (HEPA) filters. HEPA filters are made from glass paper and glue, and they may fail when they get hot or wet and when they are overpressured. In developing steel filters, they first evaluated the commercially available stainless-steel filter media made from sintered powder and sintered fiber. The sintered-fiber media performed much better than sintered-powder media, and the best media had the smallest fiber diameter. Using the best media, prototype filters were then built for venting compressed gases and evaluated in their automated filter tester

  6. Active filter for INDUS-2 Q4 and Q5 power supplies

    International Nuclear Information System (INIS)

    Singh, Y.P.; Thakurta, A.C.; Kotaiah, S.

    2003-01-01

    Q4 and Q5 power supplies are SCR based power supplies wherein the rectified voltage is fed to a passive filter to reduce the ripple voltage. The output of the passive filter still contains some ripple particularly on the low frequency side. Attenuation of this ripple with passive filter necessitates increase in size of L and C and leads to sluggishness of the system. The design and the test results of an active filter module have been discussed wherein the low frequency attenuation can be very effectively taken care of by, allowing this to be absorbed in a coupling transformer put after the passive filter. Considerable size reduction has been achieved by using switching techniques. Low frequency attenuation has been made quite a simple task. This filter also helps in handling transients from input. (author)

  7. Capability of air filters to retain airborne bacteria and molds in heating, ventilating and air-conditioning (HVAC) systems.

    Science.gov (United States)

    Möritz, M; Peters, H; Nipko, B; Rüden, H

    2001-07-01

    The capability of air filters (filterclass: F6, F7) to retain airborne outdoor microorganisms was examined in field experiments in two heating, ventilating and air conditioning (HVAC) systems. At the beginning of the 15-month investigation period, the first filter stages of both HVAC systems were equipped with new unused air filters. The number of airborne bacteria and molds before and behind the filters were determined simultaneously in 14 days-intervals using 6-stage Andersen cascade impactors. Under relatively dry ( 12 degrees C) outdoor air conditions air filters led to a marked reduction of airborne microorganism concentrations (bacteria by approximately 70% and molds by > 80%). However, during long periods of high relative humidity (> 80% R. H.) a proliferation of bacteria on air filters with subsequent release into the filtered air occurred. These microorganisms were mainly smaller than 1.1 microns therefore being part of the respirable fraction. The results showed furthermore that one possibility to avoid microbial proliferation is to limit the relative humidity in the area of the air filters to 80% R. H. (mean of 3 days), e.g. by using preheaters in front of air filters in HVAC-systems.

  8. MEMS Coupled Resonator for Filter Application in Air

    KAUST Repository

    Ilyas, Saad; Jaber, Nizar; Younis, Mohammad I.

    2017-01-01

    We present a mechanically coupled MEMS H resonator capable of performing simultaneous amplification and filter operation in air. The device comprises of two doubly clamped polyimide microbeams joined through the middle by a coupling beam of the same size. The resonator is fabricated via a multilayer surface micromachining process. A special fabrication process and device design is employed to enable the device's operation in air and to achieve mechanical amplification of the output response. Moreover, mixed-frequency excitation is used to demonstrate a tunable wide band filter. The device design combined with the mixed-frequency excitation is used to demonstrate simultaneous amplification and filtering in air.

  9. MEMS Coupled Resonator for Filter Application in Air

    KAUST Repository

    Ilyas, Saad

    2017-11-03

    We present a mechanically coupled MEMS H resonator capable of performing simultaneous amplification and filter operation in air. The device comprises of two doubly clamped polyimide microbeams joined through the middle by a coupling beam of the same size. The resonator is fabricated via a multilayer surface micromachining process. A special fabrication process and device design is employed to enable the device\\'s operation in air and to achieve mechanical amplification of the output response. Moreover, mixed-frequency excitation is used to demonstrate a tunable wide band filter. The device design combined with the mixed-frequency excitation is used to demonstrate simultaneous amplification and filtering in air.

  10. Report on intercomparison air-3/1 of the determination of trace elements in simulated air filters

    International Nuclear Information System (INIS)

    Pszonicki, L.; Veglia, A.; Suschny, O.

    1982-06-01

    The report is a sum up of an intercomparison experiment organized by the Analytical Quality Control Service of the IAEA, for simulated air filters (Air-3/1) spiked with 17 trace elements. The purpose was twofold: to assist participating laboratories in controlling their own performance, and to characterize exactly the prepared batch of air filters in order to be able to use them as reference filters for elemental trace analysis. The results submitted by 29 laboratories from 20 countries are presented and statistically processed. The analytical methods used are also specified. Conclusions concerning the use of filters Air-3/1 as certified reference filters are presented

  11. Aircraft Recirculation Filter for Air-Quality and Incident Assessment.

    Science.gov (United States)

    Eckels, Steven J; Jones, Byron; Mann, Garrett; Mohan, Krishnan R; Weisel, Clifford P

    The current research examines the possibility of using recirculation filters from aircraft to document the nature of air-quality incidents on aircraft. These filters are highly effective at collecting solid and liquid particulates. Identification of engine oil contaminants arriving through the bleed air system on the filter was chosen as the initial focus. A two-step study was undertaken. First, a compressor/bleed air simulator was developed to simulate an engine oil leak, and samples were analyzed with gas chromatograph-mass spectrometry. These samples provided a concrete link between tricresyl phosphates and a homologous series of synthetic pentaerythritol esters from oil and contaminants found on the sample paper. The second step was to test 184 used aircraft filters with the same gas chromatograph-mass spectrometry system; of that total, 107 were standard filters, and 77 were nonstandard. Four of the standard filters had both markers for oil, with the homologous series synthetic pentaerythritol esters being the less common marker. It was also found that 90% of the filters had some detectable level of tricresyl phosphates. Of the 77 nonstandard filters, 30 had both markers for oil, a significantly higher percent than the standard filters.

  12. Methodology for modeling the microbial contamination of air filters.

    Science.gov (United States)

    Joe, Yun Haeng; Yoon, Ki Young; Hwang, Jungho

    2014-01-01

    In this paper, we propose a theoretical model to simulate microbial growth on contaminated air filters and entrainment of bioaerosols from the filters to an indoor environment. Air filter filtration and antimicrobial efficiencies, and effects of dust particles on these efficiencies, were evaluated. The number of bioaerosols downstream of the filter could be characterized according to three phases: initial, transitional, and stationary. In the initial phase, the number was determined by filtration efficiency, the concentration of dust particles entering the filter, and the flow rate. During the transitional phase, the number of bioaerosols gradually increased up to the stationary phase, at which point no further increase was observed. The antimicrobial efficiency and flow rate were the dominant parameters affecting the number of bioaerosols downstream of the filter in the transitional and stationary phase, respectively. It was found that the nutrient fraction of dust particles entering the filter caused a significant change in the number of bioaerosols in both the transitional and stationary phases. The proposed model would be a solution for predicting the air filter life cycle in terms of microbiological activity by simulating the microbial contamination of the filter.

  13. Aircraft Recirculation Filter for Air-Quality and Incident Assessment

    Science.gov (United States)

    Eckels, Steven J.; Jones, Byron; Mann, Garrett; Mohan, Krishnan R.; Weisel, Clifford P.

    2015-01-01

    The current research examines the possibility of using recirculation filters from aircraft to document the nature of air-quality incidents on aircraft. These filters are highly effective at collecting solid and liquid particulates. Identification of engine oil contaminants arriving through the bleed air system on the filter was chosen as the initial focus. A two-step study was undertaken. First, a compressor/bleed air simulator was developed to simulate an engine oil leak, and samples were analyzed with gas chromatograph-mass spectrometry. These samples provided a concrete link between tricresyl phosphates and a homologous series of synthetic pentaerythritol esters from oil and contaminants found on the sample paper. The second step was to test 184 used aircraft filters with the same gas chromatograph-mass spectrometry system; of that total, 107 were standard filters, and 77 were nonstandard. Four of the standard filters had both markers for oil, with the homologous series synthetic pentaerythritol esters being the less common marker. It was also found that 90% of the filters had some detectable level of tricresyl phosphates. Of the 77 nonstandard filters, 30 had both markers for oil, a significantly higher percent than the standard filters. PMID:25641977

  14. Methodology for modeling the microbial contamination of air filters.

    Directory of Open Access Journals (Sweden)

    Yun Haeng Joe

    Full Text Available In this paper, we propose a theoretical model to simulate microbial growth on contaminated air filters and entrainment of bioaerosols from the filters to an indoor environment. Air filter filtration and antimicrobial efficiencies, and effects of dust particles on these efficiencies, were evaluated. The number of bioaerosols downstream of the filter could be characterized according to three phases: initial, transitional, and stationary. In the initial phase, the number was determined by filtration efficiency, the concentration of dust particles entering the filter, and the flow rate. During the transitional phase, the number of bioaerosols gradually increased up to the stationary phase, at which point no further increase was observed. The antimicrobial efficiency and flow rate were the dominant parameters affecting the number of bioaerosols downstream of the filter in the transitional and stationary phase, respectively. It was found that the nutrient fraction of dust particles entering the filter caused a significant change in the number of bioaerosols in both the transitional and stationary phases. The proposed model would be a solution for predicting the air filter life cycle in terms of microbiological activity by simulating the microbial contamination of the filter.

  15. D.C. side active filter for high stability accelerator magnet power supplies

    International Nuclear Information System (INIS)

    Singh, Yash Pal; Thakurta, A.C.; Kotaiah, S.

    2006-01-01

    Accelerator d.c, magnets have to produce a highly stable magnetic field which in turn needs highly stable d.c. current sources to energise them. Indus-II Q4 and Q5 power supplies are SCR based power supplies wherein the rectified voltage is fed to a passive filter to reduce the ripple voltage. The output of the passive filter still contains some ripple particularly on the low frequency side. The design and the test results of an active filter module have been discussed wherein the low frequency attenuation can be very effectively taken care of by allowing this to be absorbed in a coupling transformer put after the passive filter. Considerable size reduction has been achieved by using switching techniques. Low frequency attenuation has been made quite a simple task. This filter also helps in handling transients from input. (author)

  16. Recirculating electric air filter for use in confined spaces

    International Nuclear Information System (INIS)

    Bergman, W.; Biermann, A.; Kuhl, W.

    1985-01-01

    We have developed recirculating electric air filters for use in confined spaces where the existing ventilation system is not adequate for removing suspended particles. Two experimental filters were built and evaluated, both of which consisted of a cylindrical cartridge filter fitted over an air blower. In one design the cylindrical cartridge is a disposable unit with the electrodes and filter medium built as an integrated unit. The second design has a cylindrical cartridge that can be easily disassembled to allow replacement of the filter medium. Both designs were evaluated in a 354-ft 3 test cell using NaCl aerosols. The second design was installed and evaluated in a chamber where highly radioactive 238 PuO 2 powder is formed into pellets. We have derived equations that describe the theory of recirculating air filters. The predicted performance compares well with experimental measurements under controlled conditions. 2 refs., 7 figs., 1 tab. (DT)

  17. The high efficiency steel filters for nuclear air cleaning

    International Nuclear Information System (INIS)

    Bergman, W.; Larsen, G.; Lopez, R.; Williams, K.; Violet, C.

    1990-08-01

    We have, in cooperation with industry, developed high-efficiency filters made from sintered stainless-steel fibers for use in several air-cleaning applications in the nuclear industry. These filters were developed to overcome the failure modes in present high-efficiency particulate air (HEPA) filters. HEPA filters are made from glass paper and glue, and they may fail when they get hot or wet and when they are overpressured. In developing our steel filters, we first evaluated the commercially available stainless-steel filter media made from sintered powder and sintered fiber. The sintered-fiber media performed much better than sintered-powder media, and the best media had the smallest fiber diameter. Using the best media, we then built prototype filters for venting compressed gases and evaluated them in our automated filter tester. 12 refs., 20 figs

  18. Filtered air plastic chamber as an experimental facility to prove visible damage of crops due to air pollution

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Y; Yoda, H; Omichi, S; Shiratori, K

    1975-01-01

    An experimental filtered air chamber was constructed to prove the visible damage of crops due to air pollution. The chamber was provided with another room into which non-filtered ambient air was introduced. The purified air was prepared by filtering ambient air with activated carbon. The average content of air pollutants in the purified air chamber was less than 10 to 20% of the ozone and 20% of the sulfur oxides in the ambient air. However, cultivated vegetables such as tobacco and spinach, which are susceptible to oxidant, showed no visible damage in the filtered air chamber, and showed the same damage in the nonfiltered air chamber as was seen in fields at the same time.

  19. [Gohieria fusca found in dust of air-conditioner filters].

    Science.gov (United States)

    Qiang, Chai; Xiao-Dong, Zhan; Wei, Guo; Chao-Pin, Li

    2017-09-25

    To investigate the pollution status of Gohieria fusca in the air conditioner-filters of different places in Wuhu City. The dust samples were collected from the filters of air-conditioners in dining rooms, shopping malls, hotels and households between June and September, 2013, and G. fusca was detected in the dust samples. There were 430 dust samples collected and 98 were G. fusca positive with the breeding rate of 22.79%. The difference of breeding rates of G. fusca were statistically significant among the different places ( χ 2 =18.294, P air-conditioner filters in Wuhu City gravely.

  20. High-efficiency particulate air (HEPA) filter performance following service and radiation exposure

    International Nuclear Information System (INIS)

    Jones, L.R.

    1975-01-01

    Small HEPA filters were exposed to a 60 Co source with a radiation strength of 3 x 10 7 rads per hour and then exposed to steam--air mixtures at several times filter design flow, followed by extended exposure to steam and air at reduced flow. Additional filters were exposed to air flow in a reactor confinement system and then similarly tested with steam--air mixture flows. The test data and calculated effects of filter pluggage with moisture on confinement system performance following potential reactor accidents are described. Gamma radiation exposure impaired the performance of new filters only slightly and temporarily improved performance of service aged filters. Normal confinement system service significantly impaired filter performance although not sufficiently to prevent adequate performance of the SRP confinement system following an unlikely reactor accident. Calculations based on measured filter pluggage indicate that during an accident air flow could be reduced approximately 50 percent with service-degraded HEPA filters present, or approximately 10 percent with new filters damaged by the radiation exposure. (U.S.)

  1. Penggunaan Unit Slow Sand Filter, Ozon Generator dan Rapid Sand Filter Skala Rumah Tangga Untuk Meningkatkan Kualitas Air Sumur Dangkal Menjadi Air Layak Minum (Parameter Zat Organik dan Deterjen

    Directory of Open Access Journals (Sweden)

    Anindya Prawita Sari

    2014-09-01

    Full Text Available Air sumur merupakan air tanah yang sering kali digunakan masyarakat untuk aktivitas sehari-hari. Air sumur dengan kadar organik dan deterjen tinggi tidak layak dikonsumsi masyarakat karena dapat menyebabkan berbagai macam penyakit. Selain itu, adanya zat organik dan deterjen mempengaruhi warna dan bau air sumur sehingga tidak layak konsumsi. Slow sand filter merupakan unit pengolahan yang mampu meremoval zat organik pada air. Slow sand filter dan rapid sand filter tidak menggunakan bahan kimia dalam proses pengolahan sehingga lebih ekonomis dan efektif. Sedangkan ozon, efektif digunakan untuk meremoval zat organik yang ada dalam air dengan mengubah rantai zat organik menjadi lebih sederhana. Tujuan penelitian ini adalah untuk mengetahui keefektifan penggunaan slow sand filter, ozon generator dan rapid sand filter dalam menyisihkan beban deterjen dan zat organik pada air sumur. Hasil penelitian menunjukkan bahwa efisiensi removal pada unit slow sand filter untuk beban organik dan deterjen sebesar 57,6% dan 60,5 %, pada unit ozonasi sebesar 47,4% dan 17,5%, dan pada unit rapid sand filter sebesar 50,0% dan 50,9 %.

  2. Ammonia transformation in a biotrickling air filter

    DEFF Research Database (Denmark)

    Nielsen, Lars Peter; Nielsen, Marie Louise; Andersen, Mathias

    2007-01-01

    A simple, tubular biotrickling filter was designed for optimal removal of ammonia and odour in ventilation air from a pig house. The removal and transformation of ammonia was studied in detail by analysis and modelling of chemical gradients through the filter. Good correspondence between measurem...

  3. Simulation of the air flows in many industrial pleated filters

    International Nuclear Information System (INIS)

    Del Fabbro, L.; Brun, P.; Laborde, J.C.; Lacan, J.; Ricciardi, L.; Renoux, A.

    2000-01-01

    The study presents results concerning the characterization of the charge loss and the air flow in nuclear and automobile type pleated filters. The experimental studies in correlation with the numerical models showed an homogenous distribution of the air flows in a THE nuclear type filter, whereas the distribution is heterogenous in the case of an automobile filter. (A.L.B.)

  4. Fractional kalman filter to estimate the concentration of air pollution

    Science.gov (United States)

    Vita Oktaviana, Yessy; Apriliani, Erna; Khusnul Arif, Didik

    2018-04-01

    Air pollution problem gives important effect in quality environment and quality of human’s life. Air pollution can be caused by nature sources or human activities. Pollutant for example Ozone, a harmful gas formed by NOx and volatile organic compounds (VOCs) emitted from various sources. The air pollution problem can be modeled by TAPM-CTM (The Air Pollution Model with Chemical Transport Model). The model shows concentration of pollutant in the air. Therefore, it is important to estimate concentration of air pollutant. Estimation method can be used for forecast pollutant concentration in future and keep stability of air quality. In this research, an algorithm is developed, based on Fractional Kalman Filter to solve the model of air pollution’s problem. The model will be discretized first and then it will be estimated by the method. The result shows that estimation of Fractional Kalman Filter has better accuracy than estimation of Kalman Filter. The accuracy was tested by applying RMSE (Root Mean Square Error).

  5. Optimization of the air cargo supply chain

    Directory of Open Access Journals (Sweden)

    María Pérez Bernal

    2012-10-01

    Full Text Available Purpose: This paper aims to evaluate and optimize the various operations within the air cargo chain. It pursues to improve the efficiency of the air cargo supply chain and to provide more information to the decision-makers to optimize their fields.Design/methodology/approach: The method used is a process simulation modelling software, WITNESS, which provides information to the decision-makers about the most relevant parameters subject to optimization. The input for the simulation is obtained from a qualitative analysis of the air cargo supply chain with the involved agents and from a study of the external trade by air mode, given that their behaviour depend on the location. The case study is focused on a particular location, the Case of Zaragoza Airport (Spain.Findings: This paper demonstrates that efficiency of the air cargo supply chain can increase by leveraging several parameters such as bottlenecks, resources or warehouses.Originality/value: It explores the use of a simulation modeling software originally intended for manufacturing processes and extended to support decision making processes in the area of air cargo.

  6. A MEMS coupled resonator for frequency filtering in air

    KAUST Repository

    Ilyas, Saad

    2018-02-03

    We present design, fabrication, and characterization of a mechanically coupled MEMS H resonator capable of performing simultaneous mechanical amplification and filtering in air. The device comprises of two doubly clamped polyimide microbeams joined through the middle by a coupling beam of the same size. The resonator is fabricated via a multi-layer surface micromachining process. A special fabrication process and device design is employed to enable operation in air and to achieve mechanical amplification of the output response. Moreover, mixed-frequency excitation is used to demonstrate a tunable wide band filter for low frequency applications. It is demonstrated that through the multi-source harmonic excitation and the operation in air, an improved band-pass filter with flat response and minimal ripples can be achieved.

  7. Backflushable filter insert

    International Nuclear Information System (INIS)

    Keith, R.C.; Vandenberg, T.; Randolph, M.C.; Lewis, T.B.; Gillis, P.J. Jr.

    1988-01-01

    Filter elements are mounted on a tube plate beneath an accumulator chamber whose wall is extended by skirt and flange to form a closure for the top of pressure vessel. The accumulator chamber is annular around a central pipe which serves as the outlet for filtered water passing from the filter elements. The chamber contains filtered compressed air from supply. Periodically the filtration of water is stopped and vessel is drained. Then a valve is opened, allowing the accumulated air to flow from chamber up a pipe and down pipe, pushing the filtered water from pipe back through the filter elements to clean them. The accumulator chamber is so proportioned, relative to the volume of the system communicating therewith during backflushing, that the equilibrium pressure during backflushing cannot exceed the pressure rating of the vessel. However a line monitors the pressure at the top of the vessel, and if it rises too far a bleed valve is automatically opened to depressurise the system. The chamber is intended to replace the lid of an existing vessel to convert a filter using filter aid to one using permanent filter elements. (author)

  8. High efficiency particulate air filter experience survey

    International Nuclear Information System (INIS)

    Carbaugh, E.H.

    1983-01-01

    Causes and magnitude of HEPA filter changeouts and failures at DOE sites for the years 1977 to 1979 were evaluated. Conclusions inferred from the data follow: HEPA filters have been generally performing the task they were designed for; most changeouts have been made because of filter plugging, preventive maintenance, or precautionary reasons rather than evidence of filter failure; where failures have been experienced, records generally have not been adequate to determine the cause of failure; where cause of failure has been determined, damage attributed to personnel handling and installation has been substantially more prevalent than that from filter environmental exposure. The need for improved personnel training in handling and installation was stressed. Some reduction in filter failure frequency can be achieved by improving the acid and moisture resistance of filters, and providing adequate pretreatment of air prior to HEPA filtration

  9. Effect of Intake Air Filter Condition on Vehicle Fuel Economy

    Energy Technology Data Exchange (ETDEWEB)

    Norman, Kevin M [ORNL; Huff, Shean P [ORNL; West, Brian H [ORNL

    2009-02-01

    The U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy and the U.S. Environmental Protection Agency (EPA) jointly maintain a fuel economy website (www.fueleconomy.gov), which helps fulfill their responsibility under the Energy Policy Act of 1992 to provide accurate fuel economy information [in miles per gallon (mpg)] to consumers. The site provides information on EPA fuel economy ratings for passenger cars and light trucks from 1985 to the present and other relevant information related to energy use such as alternative fuels and driving and vehicle maintenance tips. In recent years, fluctuations in the price of crude oil and corresponding fluctuations in the price of gasoline and diesel fuels have renewed interest in vehicle fuel economy in the United States. (User sessions on the fuel economy website exceeded 20 million in 2008 compared to less than 5 million in 2004 and less than 1 million in 2001.) As a result of this renewed interest and the age of some of the references cited in the tips section of the website, DOE authorized the Oak Ridge National Laboratory (ORNL) Fuels, Engines, and Emissions Research Center (FEERC) to initiate studies to validate and improve these tips. This report documents a study aimed specifically at the effect of engine air filter condition on fuel economy. The goal of this study was to explore the effects of a clogged air filter on the fuel economy of vehicles operating over prescribed test cycles. Three newer vehicles (a 2007 Buick Lucerne, a 2006 Dodge Charger, and a 2003 Toyota Camry) and an older carbureted vehicle were tested. Results show that clogging the air filter has no significant effect on the fuel economy of the newer vehicles (all fuel injected with closed-loop control and one equipped with MDS). The engine control systems were able to maintain the desired AFR regardless of intake restrictions, and therefore fuel consumption was not increased. The carbureted engine did show a decrease in

  10. Biotreatment of air containing triethylamine (TEA vapor in biotrickling filter

    Directory of Open Access Journals (Sweden)

    A. Safari Variani

    2015-08-01

    Full Text Available Background: Treatment of waste air containing volatile organic compounds (VOCs using cheap and environmentally friendly methods is one of active fields in air pollution control. Objective: The aim of this study was to treat air containing triethylamine (TEA vapor using biotrickling filter inoculated with microbial species decomposing TEA. Methods: This experimental study was conducted in the School of Health affiliated to Qazvin University of Medical Sciences in 2014. Biotreatment was performed with biotrickling filter inoculated with microbial species decomposing TEA for two months. The biotrickling filter was set up with air containing TEA as the sole source of carbon, at Empty Bed Residence Times (EBRT of 36 sec, and inlet concentration of 84 ppm. Data were analyzed using descriptive statistics. Findings: Treatment of TEA contaminated air was made after an adaptation period of 11 days. Despite an increase in mass loading to 111 g/m3/h, TEA was eliminated with 109 g/m3/h capacity and 94-100% removal efficiency by zero order kinetics.Elimination capacity and removal efficiency were close to each other and confirmed109 g/m3/h as loading region with critical elimination capacity. Conclusion: With regards to the results, it is possible to treat air containing TEA vapor in biotrickling filter.

  11. Rational use of supply air in residential buildings

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig; Nielsen, Toke Rammer; Svendsen, Svend

    2009-01-01

    The ventilation rate influences the air quality by determining the intensity of pollution sources. This paper compared the intensity of the sensory pollution during occupied hours in an apartment ventilated by a constant air volume system and demand controlled ventilation systems controlled by oc...... by occupancy. The systems supplied the same total volume of air daily. It was found that the supply air could be used more rationally by redistributing it according to occupancy compared to maintaining a constant ventilation rate during all hours....

  12. Evaluation of residential furnace filters

    Energy Technology Data Exchange (ETDEWEB)

    Bowser, D. [Bowser Technical Inc. (Canada)

    1999-07-01

    Various filters rotated through six houses in southern Ontario during the heating season were evaluated for their filtration efficiency, including their ability to trap respirable particulate matter. Particulate levels were continuously monitored in the outside air, before and after the filter in the ducting system; also in the air in two rooms in each house. Results show that the filters performed according to their respective efficiency ratings. The integrated breathing zone exposure reading were not considered as significant as the reductions in the ducting system, dur to the fact that the integrated breathing zone exposure reflects both dust generation and dust removal mechanisms. Electronic air filters were found to produce ozone inside the home when the air-handling system was in operation. There was no evidence of any particular relationship between cleanliness and ozone production. Indoor ozone levels were always lower than outdoor levels. Continuous blower operation was found to improve filtration efficiency , however, it could result in an increase of about $250 in annual energy expenses. Bypass filters recorded significantly higher electrical energy consumption than full-flow systems. Continuous low-speed air handler fan operation appeared to be the most effective strategy. Portable air cleaners were shown to be highly effective in removing particulates in a single room. Removing footwear on entering the house, keeping major dust generators out of the house, frequent vacuuming, improving the air tightness of the house, and installing an air intake filter on the air supply may all be all be helpful in controlling exposure to particulates. 21 refs., 8 tabs., 32 figs.

  13. Air filtration and indoor air quality

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2006-01-01

    Demands for better indoor air quality are increasing, since we spend most of our time indoors and we are more and more aware of indoor air pollution. Field studies in different parts of the world have documented that high percentage of occupants in many offices and buildings find the indoor air...... decent ventilation and air cleaning/air filtration, high indoor air quality cannot be accomplished. The need for effective air filtration has increased with increasing evidence on the hazardous effects of fine particles. Moreover, the air contains gaseous pollutants, removal of which requires various air...... cleaning techniques. Supply air filter is one of the key components in the ventilation system. Studies have shown that used ventilation filters themselves can be a significant source of indoor air pollution with consequent impact on perceived air quality, sick building syndrome symptoms and performance...

  14. Effect of warm air supplied facially on occupants' comfort

    Energy Technology Data Exchange (ETDEWEB)

    Kaczmarczyk, J. [Department of Heating, Ventilation and Dust Removal Technology, Silesian University of Technology, Konarskiego 20, PL-44-101 Gliwice (Poland); Melikov, A.; Sliva, D. [Department of Civil Engineering, Technical University of Denmark, International Centre for Indoor Environment and Energy, Nils Koppels Alle, DTU, Building 402, 2800 Lyngby (Denmark)

    2010-04-15

    Human response to air movement supplied locally towards the face was studied in a room with an air temperature of 20 C and a relative humidity of 30%. Thirty-two human subjects were exposed to three conditions: calm environment and facially supplied airflow at 21 C and at 26 C. The air was supplied with a constant velocity of 0.4 m/s by means of personalized ventilation towards the face of the subjects. The airflow at 21 C decreased the subjects' thermal sensation and increased draught discomfort, but improved slightly the perceived air quality. Heating of the supplied air by 6 K (temperature increase by 4 K at the target area) above the room air temperature decreased the draught discomfort, improved subjects' thermal comfort and only slightly decreased the perceived air quality. Elevated velocity and temperature of the localized airflow caused an increase of nose dryness intensity and number of eye irritation reports. Results suggest that increasing the temperature of the air locally supplied to the breathing zone by only a few degrees above the room air temperature will improve occupants' thermal comfort and will diminish draught discomfort. This strategy will extend the applicability of personalized ventilation aiming to supply clean air for breathing at the lower end of the temperature range recommended in the standards. Providing individual control is essential in order to avoid discomfort for the most sensitive occupants. (author)

  15. Reduksi Harmonisa Pada Uninterruptible Power Supply (UPS) Dengan Single Tuned Passive Filter

    OpenAIRE

    Nasution, Agus Almi

    2017-01-01

    Using non-linier load in Uninterruptible Power Supply (UPS) can cause harmonic distortion which will eventually have the effect on power quality. The research was designed as a single-turned passive filter to cope will harmonic distortion in UPS. In this phase, THDv, THDi, and IHDi were measured in UPS. MATLAB/Simulink was used for simulation of filter testing. After single-turned passive filter was installed, the third order of harmonic current decreased from 47,69% to 7,08% or reduced 40.61...

  16. Effect of warm air supplied facially on occupants' comfort

    DEFF Research Database (Denmark)

    Kaczmarczyk, J.; Melikov, Arsen Krikor; Sliva,, D.

    2010-01-01

    was supplied with a constant velocity of 0.4 m/s by means of personalized ventilation towards the face of the subjects. The airflow at 21 °C decreased the subjects' thermal sensation and increased draught discomfort, but improved slightly the perceived air quality. Heating of the supplied air by 6 K...... (temperature increase by 4 K at the target area) above the room air temperature decreased the draught discomfort, improved subjects' thermal comfort and only slightly decreased the perceived air quality. Elevated velocity and temperature of the localized airflow caused an increase of nose dryness intensity...... and number of eye irritation reports. Results suggest that increasing the temperature of the air locally supplied to the breathing zone by only a few degrees above the room air temperature will improve occupants' thermal comfort and will diminish draught discomfort. This strategy will extend...

  17. Fungal colonization of air filters for use in heating, ventilating, and air conditioning (HVAC) systems.

    Science.gov (United States)

    Simmons, R B; Crow, S A

    1995-01-01

    New and used cellulosic air filters for HVAC systems including those treated with antimicrobials were suspended in vessels with a range of relative humidities (55-99%) and containing non-sterile potting soil which stimulates fungal growth. Most filters yielded fungi prior to suspension in the chambers but only two of 14 nontreated filters demonstrated fungal colonization following use in HVAC systems. Filters treated with antimicrobials, particularly a phosphated amine complex, demonstrated markedly less fungal colonization than nontreated filters. In comparison with nontreated cellulosic filters, fungal colonization of antimicrobial-treated cellulosic filters was selective and delayed.

  18. Particulate matter concentrations in residences: an intervention study evaluating stand-alone filters and air conditioners.

    Science.gov (United States)

    Batterman, S; Du, L; Mentz, G; Mukherjee, B; Parker, E; Godwin, C; Chin, J-Y; O'Toole, A; Robins, T; Rowe, Z; Lewis, T

    2012-06-01

    This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the child's sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the child's bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84±27%, but dropped to 63±33% in subsequent seasons. In months when households were not visited, use averaged only 34±30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. Environmental tobacco smoke (ETS) increased particulate matter (PM) levels by about 14 μg/m3 and was often detected using ETS-specific tracers despite restrictions on smoking in the house as reported on questionnaires administered to caregivers. PM concentrations depended on season, filter usage, relative humidity, air exchange ratios, number of children, outdoor PM levels, sweeping/dusting, and presence of a central air conditioner (AC). Free-standing air filters can be an effective intervention that provides substantial reductions in PM concentrations if the filters are used. However, filter use was variable across the study population and declined over the study duration, and

  19. Long term performance of particulate air-filter in an office environment

    DEFF Research Database (Denmark)

    Afshari, Alireza; Iqbal, Ahsan; Bergsøe, Niels Christian

    2015-01-01

    The present article is based on initial findings of an ongoing study. The objective of present study is to analyse the long term performance of an air particulate filter with and without ionizer. To study the performance of the air filters, a test rig was built in the Danish Building Research Ins...

  20. Air/fuel supply system for use in a gas turbine engine

    Science.gov (United States)

    Fox, Timothy A; Schilp, Reinhard; Gambacorta, Domenico

    2014-06-17

    A fuel injector for use in a gas turbine engine combustor assembly. The fuel injector includes a main body and a fuel supply structure. The main body has an inlet end and an outlet end and defines a longitudinal axis extending between the outlet and inlet ends. The main body comprises a plurality of air/fuel passages extending therethrough, each air/fuel passage including an inlet that receives air from a source of air and an outlet. The fuel supply structure communicates with and supplies fuel to the air/fuel passages for providing an air/fuel mixture within each air/fuel passage. The air/fuel mixtures exit the main body through respective air/fuel passage outlets.

  1. Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    International Nuclear Information System (INIS)

    Hayes, Robert

    2009-01-01

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level

  2. Improving indoor air quality and thermal comfort in office building by using combination filters

    Science.gov (United States)

    Kabrein, H.; Yusof, M. Z. M.; Hariri, A.; Leman, A. M.; Afandi, A.

    2017-09-01

    Poor indoor air quality and thermal comfort condition in the workspace affected the occupants’ health and work productivity, especially when adapting the recirculation of air in heating ventilation and air-conditioning (HVAC) system. The recirculation of air was implemented in this study by mixing the circulated returned indoor air with the outdoor fresh air. The aims of this study are to assess the indoor thermal comfort and indoor air quality (IAQ) in the office buildings, equipped with combination filters. The air filtration technique consisting minimum efficiency reporting value (MERV) filter and activated carbon fiber (ACF) filter, located before the fan coil units. The findings of the study show that the technique of mixing recirculation air with the fresh air through the combination filters met the recommended thermal comfort condition in the workspace. Furthermore, the result of the post-occupancy evaluation (POE) and the environmental measurements comply with the ASHRAE 55 standard. In addition, the level of CO2 concentration continued to decrease during the period of the measurement.

  3. In-situ continuous scanning high efficiency particulate air (HEPA) filter monitoring system

    International Nuclear Information System (INIS)

    Kirchner, K.N.; Johnson, C.M.; Lucerna, J.J.; Barnett, R.L.

    1985-01-01

    The testing and replacement of HEPA filters, which are widely used in the nuclear industry to purify process air before it is ventilated to the atmosphere, is a costly and labor-intensive undertaking. Current methods of testing filter performance, such as differential pressure measurement and scanning air monitoring, allow for determination of overall filter performance but preclude detection of symptoms of incipient filter failure, such as small holes in the filters themselves. Using current technology, a continual in-situ monitoring system has been designed which provides three major improvements over current methods of filter testing and replacement. This system (1) realizes a cost savings by reducing the number of intact filters which are currently being replaced unnecessarily, (2) provides a more accurate and quantitative measurement of filter performance than is currently achieved with existing testing methods, and (3) reduces personnel exposure to a radioactive environment by automatically performing most testing operations. The operation and performance of the HEPA filter monitoring system are discussed

  4. Feasibility for the medium efficiency filter as a postfilter in the air cleaning unit

    International Nuclear Information System (INIS)

    Lim, H. S.; Jung, D. Y.; Byun, S. C.; Kim, S. H.

    2002-01-01

    The Air Cleaning Unit (ACU) is provided in a nuclear facility to filter the radioactive materials in gaseous effluents released from the facility during normal operation and during a postulated accident. The Air Cleaning Unit (ACU) consists of pre-HEPA filters, charcoal adsorber, post HEPA filters, fans, etc. The charcoal filters keep on-site dose and off-site effluents ALARA, consistent with regulatory requirements. The function of HEPA filter downstream of charcoal(carbon) adsorber in ACU is to catch potential radioactive carbon dust and to be a backup in the event of failure of upstream HEPA. Previous Regulatory Guide use only post HEPA filter of charcoal adsorber downstream but the Regulatory Guide of current revisions allows use of 95% dust spot efficiency filters in lieu of HEPA at the downstream of the carbon adsorber. In this paper is described that the background information of filters, Current Regulatory Guide of revised by the United States Nuclear Regulatory Commission and the feasibility for the medium efficiency filter as a carbon adsorber post filter in the Air Cleaning Unit

  5. COMPARATIVE EVALUATION OF FILTERS USED IN TRACKING AIR TARGETS

    Directory of Open Access Journals (Sweden)

    Y. I. Strekalovskaya

    2015-01-01

    Full Text Available Using an imitation model for a flow of heterogeneous air targets the comparative assessment of the αβ, αβγ and the Kalman filters efficiency is evaluated. In the case of slightly maneuvering target the difference in filters’ efficiency is statistically insignificant; in the case of sharp maneuvering the Kalman filter is significantly more precise.

  6. Enhanced performance of a filter-sensor system.

    Science.gov (United States)

    Sasaki, Isao; Josowicz, Mira; Janata, Jirí; Glezer, Ari

    2006-06-01

    In this paper are addressed two important, but seemingly unrelated issues: long term performance of a gas sensing array and performance of an air purification unit. It is shown that when considered together, the system can be regarded as a "smart filter". The enhancement is achieved by periodic differential sampling and measurement of the "upstream" and "downstream" gases of a filter. The correctly functioning filter supplies the "zero gas" from the downstream for the continuous sensor baseline correction. A key element in this scheme is the synthetic jet that delivers well-defined pulses of the two gases. The deterioration of the performance of the "smart filter" can be diagnosed from the response pattern of the sensor. The approach has been demonstrated on removal/sensing of ammonia gas from air.

  7. Can a photocatalytic air purifier be used to improve the perceived air quality indoors?

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Wargocki, Pawel

    2010-01-01

    The effect of a photocatalytic air purifier on perceived air quality(PAQ) was examined in rooms polluted by typical sources of indoor pollution.The rooms were ventilated at three different outdoor air supply rates. The air quality was assessed by a sensory panel when the purifier was in operation...... as well as when it was off. Operation of the purifier significantly improved PAQ in the rooms polluted by building materials (used carpet, old linoleum, and old chip-board), and a used ventilation filter as well as a mixture of building materials, used ventilation filter and cathode-ray tube computer...... monitors. The effect cor-responded to approximately doubling the outdoor air supply rate. Operation of the purifier significantly worsened the PAQ in rooms with human bioeffluents, probably due to incomplete oxidation of alcohols which are one of the main pollutants emitted by humans. Present results show...

  8. Air radioactivity: to assess risks. Tools answer citizen questions. The Opera-Air network: the journey of a filter

    International Nuclear Information System (INIS)

    Didier, Damien; Gariel, Jean-Christophe; Bruno, Valerie; Debayle, Christophe

    2017-01-01

    Very highly efficient filters containing a porous glass fibre fabric are used in industrial installations to trap radioactive or toxic particles in order to limit their release, notably in accidental situations. Thus this set of articles discusses various issues related to the use of such filters. A first one describes how air radioactivity is continuously monitored by two coexisting networks: Opera-Air and Teleray. It indicates where air radioactivity comes from, and how the origin of a release can be determined, and outlines the importance of modelling tools. Air monitoring about the Gravelines nuclear power plant is briefly presented with a drawing. A second article comments the existence of numerous tools which are used as information channels about the monitoring of air radioactivity: web sites, mobile application, and so on. The last article briefly describes the journey of a filter from its removal on a Monday to a complete and validated analysis which lasts between two and four weeks

  9. A constant flow filter air sampler for workplace environments

    International Nuclear Information System (INIS)

    Parulian, A.; Rodgers, J.C.; McFarland, A.R.

    1996-01-01

    A filter air sampler has been developed for sampling radionuclide aerosol particles form the workplace environment. It provides easy filter changing, constant flow sampling, and a visual display to indicate proper operation. An experimental study was conducted to characterize the collection efficiency of the sampler as affected by variations in room air velocity, particle size, sampling flow rate, inlet geometry, and inlet orientation to the free stream. Tests were carried out in a wing tunnel at velocities between 0.3 m s -1 and 2.0 m s -1 , which is a range that covers anticipated velocities in the typical highly ventilated workplace environment of a nuclear facility. Nearly monodisperse aerosols with sizes between 5 and 20 μm aerodynamic diameter were sampled at flow rates between 28.3 and 84.9 L min -1 . Inlet orientations of 0 degree, 90 degree, and 180 degree from the horizontal were selected for evaluation. When the sampler was oriented at 0 degree over various ranges of free stream velocities, sampling flow rates and particle sizes, the transmission efficiency of aerosol was typically greater than 95%. The transmission efficiencies varied form 80% to 106% for 10-μm aerodynamic diameter particles over the previously noted range of free stream velocities and inlet orientations. Uniformity of deposits of 10 μm aerodynamic diameter particles on collection filters was examined for a sampling rate of 57 L min -1 , a sampler orientation of 90 degree into the wind and wind speeds of 0.3-2 m s -1 . The coefficients of variation for the areal density of the deposits ranged from 6.1% to 37.2%. A miniature critical flow venturi with a constant sampling flow rate of 57 L min -1 was developed for application to the new filter air sampler. It was demonstrated that the performance of the new filter air sampler is quite acceptable over a wide range of conditions. 31 refs., 8 figs., 1 tab

  10. Description of Supply Openings in Numerical Models for Room Air Distribution

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    This paper discusses various possibilities for describing supply openings in numerical models of room air distribution.......This paper discusses various possibilities for describing supply openings in numerical models of room air distribution....

  11. Dust collected in air filters - Possible source of volatile organic compounds and particles; Ger smutsiga luftfilter foersaemrad tilluft ? En studie av emissioner med ursprung i filter

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, J.H.P.; Rosell, Lars

    1998-06-01

    Emissions from dust collected in air filters have been investigated using in situ measurements. Two air filters of different classes (F6 and F8/9) have been exposed to outdoor air for a preconditioning period of six months. After this period measurements have been carried out using two operating conditions, continuous and intermittent. Air samples were taken both up- and downstream of the filters. The air samples were analysed regarding volatile organic compounds (VOCs), including formaldehyde and microbial VOCs (mVOC) and the samples of airborne dust were examined regarding the contents of colony forming units, ergosterol (marker of fungi), and endotoxin (marker of gram negative bacteria). Furthermore, a visual inspection of the airborne dust was conducted using SEM. Particles released when the fan was turned on and a short period after, were monitored using an optical particle counter, slitsamplers (fungus spores) and membrane filters for SEM analysis. After finishing the in situ measurements, the filters were placed in climate chambers for emission sampling. Finally, samples were cut out for analysis of microbial contents in the filter material, both on the dusty and `clean` side of the filters. No consistent change of VOC, aldehyde or mVOC concentrations across the filters could be measured. A significant ozone reduction was seen in one of the in situ measurements. The chamber experiments showed that the filters were a source of various VOCs, e.g. aldehydes and mVOCs. The emission of mVOCs in the chambers was significantly higher for the F8/9 filter, probably due to more and finer dust in that filter. Only a few colonization units (fungi) penetrate filters when running continuously but an increase was noted at the moment the fans were started. The same phenomenon was observed with the optical particle counter, but both the intensity and length of the increase, for colonization units and other particles, were moderate. Mycological examination of the filter

  12. Capacitor current feedback for output filter damping in switched-mode magnet power supplies

    International Nuclear Information System (INIS)

    Paven Kumar, M.R.; Kim, J.M.S.

    1994-01-01

    In magnet power supplies for a particle accelerator system, a second-order low-pass filter is used to reduce the output current ripple content within specifications. The output filter must be properly damped in order to avoid any large amplification at the resonant frequency and large transient responses of voltages and currents at the step change of the line voltage. Conventionally, a series combination of resistance and capacitance is added in parallel with the filter capacitor to provide the required damping. This approach, however, requires a large dc-blocking capacitor which has to be several times larger than the filter capacitor. In this paper, a filter damping technique using capacitor current feedback is presented. The basic concept of the capacitor current feedback is established using a linear model of the converter involved, and then a sampled-data model of the converter is used to analyze the filter damping technique. The filter damping effect of the capacitor current feedback is verified experimentally

  13. Air-drop blood supply in the French Army.

    Science.gov (United States)

    Javaudin, Olivier; Baillon, A; Varin, N; Martinaud, C; Pouget, T; Civadier, C; Clavier, B; Sailliol, A

    2018-02-12

    Haemorrhagic shock remains the leading cause of preventable death in overseas and austere settings. Transfusion of blood components is critical in the management of this kind of injury. For French naval and ground military units, this supply often takes too long considering the short shelf-life of red blood cell concentrates (RBCs) and the limited duration of transport in cooling containers (five to six days). Air-drop supply could be an alternative to overcome these difficulties on the condition that air-drop does not cause damage to blood units. After a period of study and technical development of packaging, four air-drops at medium and high altitudes were performed with an aircraft of the French Air Force. After this, one air-drop was carried out at medium altitude with 10 RBCs and 10 French lyophilised plasma (FLYP). A second air-drop was performed with a soldier carrying one FLYP unit at 12 000 feet. For these air-drops real blood products were used, and quality control testing and temperature monitoring were performed. The temperatures inside the containers were within the normal ranges. Visual inspection indicated that transfusion packaging and dumped products did not undergo deterioration. The quality control data on RBCs and FLYP, including haemostasis, suggested no difference before and after air-drop. The operational implementation of the air-drop of blood products seems to be one of the solutions for the supply of blood products in military austere settings or far forward on battlefield, allowing safe and early transfusion. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Air Cleaning Devices for HVAC Supply Systems in Schools. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.

    Guidelines for maintaining indoor air quality in schools with HVAC air cleaning systems are provided in this document. Information is offered on the importance of air cleaning, sources of air contaminants and indoor pollutants, types of air cleaners and particulate filters used in central HVAC systems, vapor and gas removal, and performance…

  15. Modelling of air flows in pleated filters and of their clogging by solid particles

    International Nuclear Information System (INIS)

    Del Fabbro, L.

    2002-01-01

    The devices of air cleaning against particles are widely spread in various branches of industry: nuclear, motor, food, electronic,...; among these devices, numerous are constituted by pleated porous media to increase the surface of filtration and thus to reduce the pressure drop, for given air flow. The objective of our work is to compensate a lack evident of knowledge on the evolution of the pressure drop of pleated filter during the clogging and to deduct a modelling from it, on the basis of experiments concerning industrial filters of nuclear and car types. The obtained model is a function of characteristics of the filtering medium and pleats, of the characteristics of solid particles deposited on the filter, of the mass of particles and of the aeraulic conditions of air flow. It also depends on data on the clogging of flat filters of equivalent medium. To elaborate this model of pressure drop, an initial stage was carried out in order to characterize, experimentally and numerically, the pressure drop and the distribution of air flow in clean pleated filters of nuclear (high efficiency particulate air filter, in fiberglasses) and car (mean efficiency filter, in fibers of cellulose) types. The numerical model allowed to understand the fundamental role played by the aeraulic resistance of the filtering medium. From an non-dimensional approach, we established a semi-empirical model of pressure drop for a clean pleated filter valid for both studied types of medium; this model is used of first base for the development of the final model of clogging. The study of the clogging of the filters showed the complexity of the phenomenon dependent mainly on a reduction of the surface of filtration. This observation brings us to propose a clogging of pleated filters in three phases. Both first phases are similar in those observed for flat filters, while last phase corresponds to a reduction of the surface of filtration and leads a strong increase of the filter pressure drop

  16. The Fate of Mengovirus on Fiberglass Filter of Air Handling Units.

    Science.gov (United States)

    Bandaly, Victor; Joubert, Aurélie; Le Cann, Pierre; Andres, Yves

    2017-12-01

    One of the most important topics that occupy public health problems is the air quality. That is the reason why mechanical ventilation and air handling units (AHU) were imposed by the different governments in the collective or individual buildings. Many buildings create an artificial climate using heating, ventilation, and air-conditioning systems. Among the existing aerosols in the indoor air, we can distinguish the bioaerosol with biological nature such as bacteria, viruses, and fungi. Respiratory viral infections are a major public health issue because they are usually highly infective. We spend about 90% of our time in closed environments such as homes, workplaces, or transport. Some studies have shown that AHU contribute to the spread and transport of viral particles within buildings. The aim of this work is to study the characterization of viral bioaerosols in indoor environments and to understand the fate of mengovirus eukaryote RNA virus on glass fiber filter F7 used in AHU. In this study, a set-up close to reality of AHU system was used. The mengovirus aerosolized was characterized and measured with the electrical low pressure impact and the scanner mobility particle size and detected with RT-qPCR. The results about quantification and the level of infectivity of mengovirus on the filter and in the biosampler showed that mengovirus can pass through the filter and remain infectious upstream and downstream the system. Regarding the virus infectivity on the filter under a constant air flow, mengovirus was remained infectious during 10 h after aerosolization.

  17. ALMERA Proficiency Test: Determination of Gamma Emitting Radionuclides in Simulated Air Filters

    International Nuclear Information System (INIS)

    2010-01-01

    The activity concentration of radionuclides in air is a critical factor in assessing the air quality and the potential impact of possible pollutants. Air is in fact one of the main pathways for human exposure to radioactivity. Radioactivity may be present in the atmosphere due to natural processes; intentional (low level) anthropogenic release; or as a consequence of nuclear or radiological incident. The resulting environmental impact should be considered carefully to ensure safety and compliance with environmental regulations. A reliable determination of radionuclides in air is necessary for regular monitoring of air quality to comply with radiation protection and environmental regulations. This proficiency test (PT) is one of the series of the ALMERA network proficiency tests organised on regular basis by the Terrestrial Environment Laboratory in Seibersdorf, designed to assess the technical capacity of ALMERA Members in analysing radionuclides to identify any analytical problems and to support ALMERA laboratories to maintain their preparedness to provide rapid and reliable analytical results. The range of simulated air filters used in this PT for analysis has been mainly at environmental level. The PT set consisted of four filters. The participating laboratories were requested to analyze Mn-54, Co-57, Fe-59, Co-60, Zn-65, Cd-109, Ba-133, Cs-134, Cs-137, Eu-152 and Am-241 in filters 01, 02 and 03. The participants were informed that only some of the listed radionuclides were present in the filters and the levels of the radionuclides were such that they could be measured within a 6-hour measurement period using a conventional HPGe gammaspectrometer of 35% relative efficiency. Filter 04, was containing only Co-60 and Ba-133 with known activities to the participants, had to be used as a control for the efficiency calibration. The tasks of IAEA were to prepare and distribute the simulated air filters to the participating laboratories, to collect and interpret

  18. Overcurrent Abuse of Primary Prismatic Zinc–Air Battery Cells Studying Air Supply Effects on Performance and Safety Shut-Down

    Directory of Open Access Journals (Sweden)

    Fredrik Larsson

    2017-01-01

    Full Text Available Overcurrent abuse has been performed on commercial 48 Ah primary prismatic zinc (Zn–Air battery cells with full air supply as well as with shut-off air supply. Compared to other battery technologies, e.g., lithium-ion batteries, metal–air batteries offer the possibility to physically stop the battery operation by stopping its air supply, thus offering an additional protection against severe battery damage in the case of, e.g., an accidental short circuit. This method may also reduce the electrical hazard in a larger battery system since, by stopping the air supply, the voltage can be brought to zero while maintaining the energy capacity of the battery. Measurements of overdischarge currents and current cut-off by suffocation have been performed to assess the safety of this type of Zn–air battery. The time to get to zero battery voltage is shown to mainly be determined by the volume of air trapped in the cell.

  19. [Research on dust mite allergen gathered from filters of air-conditioners].

    Science.gov (United States)

    Zhan, Xiao-dong; Wu, Hua; Hu, Hui-min; Li, Chao-pin

    2015-12-01

    To discuss the relation between the dust mite allergen (Der) in air-conditioner filters and the asthma attack. The dust samples were collected from the filters of air-conditioners in dining rooms, shopping malls, hotels and households, respectively. The concentrations of Der f 1 and Der p1 were detected by ELISA, and the dust mite immune activities were determined by dot-ELISA. The concentrations of Der f 1 in the dining rooms, shopping malls, hotels and households were 1.52, 1.24, 1.31 µg/g and 1.46 µg/g respectively, and the concentrations of Der p 1 were 1.23, 1.12, 1.16 µg/ g and 1.18 µg, respectively. One hour after the running of air-conditioners, the concentrations of Der f 1 and Der p 1 in the air were higher than those before the running of air-conditioners, and the differences were significant (P air-conditioners in domestic houses in Wuhu City, and the allergens can induce asthma.

  20. Ventilation air conditioner for a reactor container

    International Nuclear Information System (INIS)

    Ikegame, Noboru; Nakagawa, Takeshi.

    1980-01-01

    Purpose: To suppress the variations in the internal pressure of a reactor container and smoothly ventilate the reactor container. Constitution: The air conditioner provides an air-flow-rate-control damper, a purge-air supply fan, and a filter device in the air-supply pipe of a reactor container. Furthermore, it provides a pressure difference detector at a part of the container. The air-flow-rate-control damper is connected electrically through a position-modulator-comparison amplifier to the pressure difference detector. When the filtration becomes insufficient by clogging of the filter device and the internal pressure increased abruptly in the container, the pressure-difference detector can detect it, and the damper is operated by a pressure regulator and the comparator so as to control the air flow to the container. Thus, the internal pressure variation is controlled so as to easily ventilate the container. (J.P.N.)

  1. Tunable dual-channel filter based on the photonic crystal with air defects.

    Science.gov (United States)

    Zhao, Xiaodan; Yang, Yibiao; Wen, Jianhua; Chen, Zhihui; Zhang, Mingda; Fei, Hongming; Hao, Yuying

    2017-07-01

    We propose a tuning filter containing two channels by inserting a defect layer (Air/Si/Air/Si/Air) into a one-dimensional photonic crystal of Si/SiO 2 , which is on the symmetry of the defect. Two transmission peaks (1528.98 and 1564.74 nm) appear in the optical communication S-band and C-band, and the transmittance of these two channels is up to 100%. In addition, this design realizes multi-channel filtering to process large dynamic range or multiple independent signals in the near-infrared band by changing the structure. The tuning range will be enlarged, and the channels can be moved in this range through the easy control of air thickness and incident angle.

  2. PENGGUNAAN BERBAGAI JENIS FILTER UNTUK PEMELIHARAAN IKAN HIAS AIR TAWAR DI AKUARIUM

    Directory of Open Access Journals (Sweden)

    Bambang Priono

    2012-12-01

    Full Text Available Akuarium merupakan salah satu wadah untuk pemeliharaan ikan hias baik tawar maupun laut, betapapun indahnya ikan hias apabila tidak ditunjang dengan penampilan, aksesoris, dan dekorasi yang memadai, maka nilai keindahan akan berkurang. Penggunaan filter untuk mendukung salah satu sintasan ikan hias sangat penting. Terdapat banyak jenis-jenis filter yang dapat digunakan di dalam akuarium, dengan bentuk, desain, ukuran, dan harga yang bermacam-macam pula. Namun demikian, fungsi utama filter sebernarnya adalah untuk (1 menghilangkan atau mengangkat kotoran atau sisa kotoran dari air, (2 mengangkat atau menghilangkan bahan kimia dari air yang membuat air menjadi berwarna (warna coklat/keruh atau bahan yang tak dikehendaki, dan (3 menghilangkan kotoran ikan dan menguraikan produk atau zat yang beracun menjadi tak beracun untuk ikan.

  3. A MEMS coupled resonator for frequency filtering in air

    KAUST Repository

    Ilyas, Saad; Jaber, Nizar; Younis, Mohammad I.

    2018-01-01

    We present design, fabrication, and characterization of a mechanically coupled MEMS H resonator capable of performing simultaneous mechanical amplification and filtering in air. The device comprises of two doubly clamped polyimide microbeams joined

  4. Reduced heat stress in offices in the tropics using solar powered drying of the supply air

    DEFF Research Database (Denmark)

    Gunnarsen, Lars; Santos, A M B

    2002-01-01

    air may facilitate personal cooling by increased evaporation of sweat. Heat acclimatized people with efficient sweating may in particular benefit from this cooling. A prototype solar powered supply system for dried-only air was made. Air from the system was mixed with room air, heated to six different...... content of room air, temperature of supply air and moisture content of supply air was developed based on the experiments. Reduction of moisture content in the supply air by 1.6 g/kg had the same effect as lowering the operative temperature by 1 degree C. The solar-powered system for supplying dry air...... is a low-cost alternative to traditional air conditioning in hot and humid regions....

  5. Application of air ions for bacterial de-colonization in air filters contaminated by aerosolized bacteria

    International Nuclear Information System (INIS)

    Kim, Yang Seon; Yoon, Ki Young; Park, Jae Hong; Hwang, Jungho

    2011-01-01

    We aerosolized the Escherichia coli (E. coli) and Staphylococcus epidermidis (S. epidermidis) bacteria and collected them on membrane filters. Then we generated air ions by applying a high voltage to a carbon fiber tip and applied them to the contaminated filters. The antibacterial efficiency was not significantly affected by the bacteria being Gram-positive or Gram-negative, however, negative ions showed a lower antibacterial efficiency than positive ions to both E. coli and S. epidermidis, even though the concentration of negative air ions was much higher than that of positive air ions. With a field emission scanning electron microscope (FE-SEM) images and fluorescence microscopy images using a LIVE/DEAD BacLight Bacterial Viability Kit, electrostatic disruption of the bacteria was found to be the dominant antibacterial effect. - Research Highlights: →This study examined the effects of air ions generated by a carbon fiber ionizer on the inactivation of bioaerosols. →When the ion exposure time and the ion generation concentration were increased, the antibacterial efficiency increased. →The bioaerosols carried a significant number of negative electrical charges. →Negative ions showed lower antibacterial efficiency than positive ions to both E. coli and S. epidermidis, even though the concentration of negative air ions was much higher than that of positive air ions.

  6. Experimental research on the flow field uniformity in the filter house of a nuclear air cleaning system

    International Nuclear Information System (INIS)

    Jiang Feng; Yang Jun; Ye Suisheng

    2000-01-01

    The filter house structure is designed using similarity laws showing that the filter house structure causes a non-uniform flow field. The flow field is also measured experimentally. The air flow field is analyzed for different conditions. The results show that: (1) The HEPA filters affect the dispersion of the air flow; (2) The appropriate angle for air input to the rectifier satisfies the requirements for uniform air flow for the test conditions; (3) The rectifier has little influence on the air flow for operating conditions

  7. Scaling of Supply Voltage in Design of Energy Saver FIR Filter on 28nm FPGA

    DEFF Research Database (Denmark)

    Pandey, Bishwajeet; Jain, Vishal; Sharma, Rashmi

    2017-01-01

    In this work, we are going to analyze the effect of main supply voltage, auxiliary supply voltage, local voltage of different power bank, and supply voltage in GTX transceiver and BRAM on power dissipation of our FIR design using Verilog during implementation on 28nm FPGA. We have also taken three.......33%, 86%, 90.67%, 65.33%, 52%, and 48.67% reduction in IO power dissipation of FIR Filter design on CSG324 package of Artix-7 FPGA family....

  8. INTERACTION OF AIR TRANSPORTATION AND FUEL-SUPPLY COMPANIES

    Directory of Open Access Journals (Sweden)

    I. P. Zheleznaya

    2014-01-01

    Full Text Available The article describes the role of aviation fuel in the life of air transport. Fueling industry worldwide solves two main tasks - ensuring the safety and economy of air traffic. In Russia, there is one more task of airlines fuel supply. The article deals with fuel pricing taking into consideration today's realities.

  9. The sampling of hydrogen fluoride in air with impregnated filter paper

    NARCIS (Netherlands)

    Huygen, C.

    1963-01-01

    A method isproposed for the quantitative collection of hydrogen fluoride in air by drawing a known quantity of the air through filter paper impregnated with solutions of potassium hydroxide and glycerol or triethanolamine. Somu possibilities and limitations of the method are discussed.

  10. PubMed search filters for the study of putative outdoor air pollution determinants of disease

    Science.gov (United States)

    Curti, Stefania; Gori, Davide; Di Gregori, Valentina; Farioli, Andrea; Baldasseroni, Alberto; Fantini, Maria Pia; Christiani, David C; Violante, Francesco S; Mattioli, Stefano

    2016-01-01

    Objectives Several PubMed search filters have been developed in contexts other than environmental. We aimed at identifying efficient PubMed search filters for the study of environmental determinants of diseases related to outdoor air pollution. Methods We compiled a list of Medical Subject Headings (MeSH) and non-MeSH terms seeming pertinent to outdoor air pollutants exposure as determinants of diseases in the general population. We estimated proportions of potentially pertinent articles to formulate two filters (one ‘more specific’, one ‘more sensitive’). Their overall performance was evaluated as compared with our gold standard derived from systematic reviews on diseases potentially related to outdoor air pollution. We tested these filters in the study of three diseases potentially associated with outdoor air pollution and calculated the number of needed to read (NNR) abstracts to identify one potentially pertinent article in the context of these diseases. Last searches were run in January 2016. Results The ‘more specific’ filter was based on the combination of terms that yielded a threshold of potentially pertinent articles ≥40%. The ‘more sensitive’ filter was based on the combination of all search terms under study. When compared with the gold standard, the ‘more specific’ filter reported the highest specificity (67.4%; with a sensitivity of 82.5%), while the ‘more sensitive’ one reported the highest sensitivity (98.5%; with a specificity of 47.9%). The NNR to find one potentially pertinent article was 1.9 for the ‘more specific’ filter and 3.3 for the ‘more sensitive’ one. Conclusions The proposed search filters could help healthcare professionals investigate environmental determinants of medical conditions that could be potentially related to outdoor air pollution. PMID:28003291

  11. PubMed search filters for the study of putative outdoor air pollution determinants of disease.

    Science.gov (United States)

    Curti, Stefania; Gori, Davide; Di Gregori, Valentina; Farioli, Andrea; Baldasseroni, Alberto; Fantini, Maria Pia; Christiani, David C; Violante, Francesco S; Mattioli, Stefano

    2016-12-21

    Several PubMed search filters have been developed in contexts other than environmental. We aimed at identifying efficient PubMed search filters for the study of environmental determinants of diseases related to outdoor air pollution. We compiled a list of Medical Subject Headings (MeSH) and non-MeSH terms seeming pertinent to outdoor air pollutants exposure as determinants of diseases in the general population. We estimated proportions of potentially pertinent articles to formulate two filters (one 'more specific', one 'more sensitive'). Their overall performance was evaluated as compared with our gold standard derived from systematic reviews on diseases potentially related to outdoor air pollution. We tested these filters in the study of three diseases potentially associated with outdoor air pollution and calculated the number of needed to read (NNR) abstracts to identify one potentially pertinent article in the context of these diseases. Last searches were run in January 2016. The 'more specific' filter was based on the combination of terms that yielded a threshold of potentially pertinent articles ≥40%. The 'more sensitive' filter was based on the combination of all search terms under study. When compared with the gold standard, the 'more specific' filter reported the highest specificity (67.4%; with a sensitivity of 82.5%), while the 'more sensitive' one reported the highest sensitivity (98.5%; with a specificity of 47.9%). The NNR to find one potentially pertinent article was 1.9 for the 'more specific' filter and 3.3 for the 'more sensitive' one. The proposed search filters could help healthcare professionals investigate environmental determinants of medical conditions that could be potentially related to outdoor air pollution. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Selection of filter media in alpha air monitors for emergency environmental monitoring

    International Nuclear Information System (INIS)

    Kinouchi, N.; Oishi, T.; Noguchi, H.; Kato, S.

    2000-01-01

    We have developed an alpha air monitor which is possible to measure rapidly and sensitively the concentrations of airborne alpha-emitting particles, such as plutonium, for the environmental monitoring at an accident of nuclear reprocessing plant. The monitor is designed to collect airborne alpha-emitting particles by drawing the ambient air through a filter and to detect the activity by alpha spectroscopy. In order to achieve high-sensitive measurements, selection of a suitable filter used in the monitor is considerably important. The most important requirement for the filter is that it has a high surface collection efficiency to obtain the sharpness of the alpha energy spectrum. This makes it easy to distinguish the alpha-ray peak of plutonium from the alpha spectrum of naturally occurring radon decay products in the environment. And the filter is also desired to have low resistance of the air flow so that particles can be collected at a high flowrate. We have made a comparison of the surface collection efficiency and pressure drop for the various filters. Types of the test filters, most of which are commercially available in Japan, were glass fiber, cellulose-glass fiber, membrane and so on. The surface collection efficiency has been evaluated by the following two indices. One was the sharpness of alpha-ray energy peaks of thoron decay products generated in a laboratory and collected in the fibers. The other was the background counts of radon decay products in a plutonium region by measuring alpha-ray energy spectrum of radon decay products collected in the filters by sampling of dust in the atmosphere. It was found that the PTFE (polytetrafluoroethylene) membrane filter with backing had a high surface collection efficiency and low pressure drop. The results of the test are described in detail in this paper. (author)

  13. Development of activated charcoal impregnated air sampling filter media : their characteristics and use

    International Nuclear Information System (INIS)

    Khan, A.A.; Ramarathinam, K.; Gupta, S.K.; Deshingkar, D.S.; Kishore, A.G.

    1975-01-01

    Because of its low maximum permissible concentration in air, air-borne radioiodine must be accurately monitored in contaminated air streams, in the working environment and handling facilities, before release to the environment from the nuclear facilities. Activated charcoal impregnated air sampling filter media are found to be most suitable for monitoring airborne iodine-131. Because of its simplicity and reproducible nature in assessment of air-borne radioactive iodine, the work on the development of such media was undertaken in order to find a suitable substitute for imported activated charcoal impregnated air sampling filter media. Eight different media of such type were developed, evaluated and compared with two imported media. Best suitable medium is recommended for its use in air-borne iodine sampling which was found to be even better suited than imported media of such type. (author)

  14. Air sampling by pumping through a filter: effects of air flow rate, concentration, and decay of airborne substances

    OpenAIRE

    Šoštarić, Marko; Petrinec, Branko; Babić, Dinko

    2016-01-01

    This paper tackles the issue of interpreting the number of airborne particles adsorbed on a filter through which a certain volume of sampled air has been pumped. This number is equal to the product of the pumped volume and particle concentration in air, but only if the concentration is constant over time and if there is no substance decomposition on the filter during sampling. If this is not the case, one must take into account the inconstancy of the concentration and the decay law for a give...

  15. Features of adsorbed chemical elements and their isotopes distribution in iodine air filters AU-1500 of nuclear power plant

    International Nuclear Information System (INIS)

    Neklyudov, I.M.; Dovbnya, A.N.; Dikiy, N.P.; Ledenyov, O.P.; Lyashko, Yu.V.

    2013-01-01

    The main aim of research is to investigate the physical features of spatial distribution of the adsorbed chemical elements and their isotopes in the granular filtering medium in the iodine air filters of the type of AU-1500 in the forced-exhaust ventilation at the nuclear power plant. The ?-activation analysis method is applied to accurately characterize the distribution of the adsorbed radioactive chemical elements and their isotopes in the granular filtering medium in the AU-1500 iodine air filter after its long term operation at the nuclear power plant. The typical spectrum of the detected chemical elements and their isotopes in the AU-1500 iodine air filter, which was exposed by the irradiation of bremsstrahlung gamma-quantum producing by the accelerating electrons in the tantalum target, are obtained. The spatial distributions of the detected chemical element 127 I and some other chemical elements and their isotopes in the layer of absorber, which was made of the cylindrical coal granules of the type of SKT-3, in the AU-1500 iodine air filter are also researched. The possible influences by the standing wave of air pressure in the iodine air filter on the spatial distribution of the chemical elements and their isotopes in the iodine air filter are discussed. The comprehensive analysis of obtained research results on the distribution of the adsorbed chemical elements and their isotopes in the absorber of iodine air filter is performed.

  16. The Design of Compressed air system in the Conventional Facility of Proton Accelerator Research Center

    International Nuclear Information System (INIS)

    Jeon, G. P.; Kim, J. Y.; Cho, S. W.; Min, Y. S.; Mun, K. J.; Cho, J. S.; Nam, J. M.; Park, S. S.; Jo, J. H.

    2012-01-01

    The Compressed Air System (CA) supplies compressed air for all air operated devices and instruments, pneumatic equipment and other miscellaneous air user points in the Conventional Facilities of Proton Engineering Frontier Project. CA System consist of the Instrument Air System and the Service air System. The Instrument Air System supplies oil-free, dried, filtered, and compressed instrument air for the air operated control devices and instruments in the Accelerator and Beam Application Building, Ion Beam Application Building, Utility Building and etc.. The Service air System supplies compressed air for pneumatic equipment and other services

  17. Distribution and rate of microbial processes in ammonia-loaded air filter biofilm

    DEFF Research Database (Denmark)

    Juhler, Susanne; Nielsen, Lars Peter; Schramm, Andreas

    2009-01-01

    The in situ activity and distribution of heterotrophic and nitrifying bacteria and their potential interactions were investigated in a full-scale, two-section, trickling filter designed for biological degradation of volatile organics and NH3 in ventilation air from pig farms. The filter biofilm...

  18. Filters from taxis air conditioning system: A tool to characterize driver's occupational exposure to bioburden?

    Science.gov (United States)

    Viegas, Carla; Monteiro, Ana; Dos Santos, Mateus; Faria, Tiago; Caetano, Liliana Aranha; Carolino, Elisabete; Quintal Gomes, Anita; Marchand, Geneviève; Lacombe, Nancy; Viegas, Susana

    2018-07-01

    Bioburden proliferation in filters from air conditioning systems of taxis represents a possible source of occupational exposure. The aim of this study was to determine the occurrence of fungi and bacteria in filters from the air conditioning system of taxis used for patient transportation and to assess the exposure of drivers to bioburden. Filters from the air conditioning systems of 19 taxis and 28 personal vehicles (used as controls) operating in three Portuguese cities including the capital Lisbon, were collected during the winter season. The occurrence and significance of bioburden detected in the different vehicles are reported and discussed in terms of colony-forming units (CFU) per 1 m 2 of filter area and by the identification of the most frequently detected fungal isolates based on morphology. Azole-resistant mycobiota, fungal biomass, and molecular detection of Aspergillus species/strains were also determined. Bacterial growth was more prevalent in taxis (63.2%) than in personal vehicles (26.3%), whereas fungal growth was more prevalent in personal vehicles (53.6%) than in taxis (21.1-31.6%). Seven different azole-resistant species were identified in this study in 42.1% taxi filters. Levels of fungal biomass were above the detection limit in 63% taxi filters and in 75% personal vehicle filters. No toxigenic species were detected by molecular analysis in the assessed filters. The results obtained show that bioburden proliferation occurs widely in filters from the air conditioning systems of taxis, including the proliferation of azole-resistant fungal species, suggesting that filters should be replaced more frequently. The use of culture based-methods and molecular tools combined enabled an improved risk characterization in this setting. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Improving indoor air quality by using the new generation of corrugated cardboard-based filters.

    Science.gov (United States)

    Candiani, Gabriele; Del Curto, Barbara; Cigada, Alberto

    2012-09-27

    Indoor Air Quality (IAQ) is strictly affected by the concentration of total suspended particulate matter (TSP). Air filtration is by far the most feasible suggestion to improve IAQ. Unfortunately, highly effective HEPA filters also have a few major weaknesses that have hindered their widespread use. There is therefore a renewed interest in developing novel, cost-effective filtration systems. We have recently reported the development of cardboard-based filters for bacterial removal that were further implemented and tested herein. A parallelepiped filter manufactured by aligning strips of corrugated cardboard and surrounded by a cardboard frame was specifically designed with an internal pocket holding a partially cut antistatic pleated fabric (HP). This filter, together with its parent version (CTRL) and a commercially sourced specimen (CAF), were assessed comparatively in a long-time test to assess their effectiveness on TSP removal. We found that the TSP abatement efficiency (E%) of the HP filter was relatively high and invariable over the 93 days of test and the pressure drop (PD%) decrease because of filter clogging was moderate. Most important, the HP filter was the most effective if assessed in terms of overall yield (Y%) and its performance was quite constant over the entire period considered. This work disclosed this novel class of corrugated cardboard-based filters as promising tools to ameliorate IAQ in light of their good TSP removal properties that endure over time. Moreover, cardboard is a lightweight, inexpensive, and eco-friendly material and corrugated cardboard-based air filters are very easy to shape and mount on and/or replace in existing ventilation systems.

  20. Specifications and test procedures for airline-type supplied-air suits

    International Nuclear Information System (INIS)

    Revoir, W.H.; Pritchard, J.A.; Davis, T.O.; Richards, C.P.; Wheat, L.D.

    1975-05-01

    Procedures and requirements have been established to permit airline-type supplied-air suits needed by contractors of the Energy Research and Development Administration to be tested for performance by the Respirator Research and Development Section, Industrial Hygiene Group, of the Los Alamos Scientific Laboratory, and to have the adequacy of the performance of these devices evaluated by the Los Alamos Scientific Laboratory Respirator Advisory Committee. Test equipment, test methods, and performance criteria for airline-type supplied-air suits are prescribed. (U.S.)

  1. Acaroid mite allergens from the filters of air-conditioning system in China.

    Science.gov (United States)

    Li, Chao-Pin; Guo, Wei; Zhan, Xiao-Dong; Zhao, Bei-Bei; Diao, Ji-Dong; Li, Na; He, Lian-Ping

    2014-01-01

    Accumulation of acaroid mites in the filters of air-conditioners is harmful to human health. It is important to clarify the allergen components of mites from the filters of local air-conditioning system. The present study was to detect the allergen types in the filters of air-conditioners and assesse their allergenicity by asthmatic models. Sixty aliquots of dust samples were collected from air conditioning filters in civil houses in Wuhu area. Total protein was extracted from the dust samples using PBS and quantified by Bradford method. Allergens I and II were also detected by Western blot using primary antibody (anti-Der f1/2, Der p1/Der f2/Der p2, respectively). Ten aliquots of the positive samples were randomly selected for homogenization and sensitized the mice for developing asthmatic animal models. Total serum IgE level and IFN-γ, IL-4 and IL-5 in the bronchoalveolar lavage fluid (BALF). The allergenicity of the extraction was assessed using pathological sections developed from the mouse pulmonary tissues. The concentration of extract from the 60 samples was ranged from 4.37 μg/ml to 30.76 μg/ml. After analyzing with Western blot, 31 of 60 samples were positive for 4 allergens of acaroid mites, and yet 16 were negative. The levels of total IgE from serum IL-4 and IL-5 from the BALF in the experimental group were apparently higher than that of negative control and PBS group (P 0.05). However,the IFN-γ level in BALF was lower compared with the negative control and PBS group (P 0.05). The pathological changes were evidently emerged in pulmonary tissues, which were similar to those of OVA group, compared with the PBS ground and negative controls. The air-conditioner filters in human dwellings of Wuhu area potentially contain the major group allergen 1 and 2 from D. farinae and D. pteronyssinus, which may be associated with seasonal prevalence of allergic disorders in this area.

  2. Development of DC active filter for high magnetic field stable power supply

    International Nuclear Information System (INIS)

    Wang Lei; Liu Xiaoning

    2008-01-01

    The DC active filter (DAF), with very low current ripple, of the stable power supply system of high magnetic field device is developed by using the PWM and parallel active power filter technique. Due to the PWM control technique, the required DAF current can be obtained and the current ripple can be compensated by means of monitoring the load voltage, and the current ripple becomes very low by adjusting the load voltage. The simulation and analysis show that this system can respond to the reference quickly and is effective in suppressing the harmonics, especially the low-order harmonics. The feasibility of the proposed scheme is proved on the equipment built in the laboratory. (authors)

  3. Air-mass flux measurement system using Doppler-shifted filtered Rayleigh scattering

    Science.gov (United States)

    Shirley, John A.; Winter, Michael

    1993-01-01

    An optical system has been investigated to measure mass flux distributions in the inlet of a high speed air-breathing propulsion system. Rayleigh scattered light from air is proportional to the number density of molecules and hence can be used to ascertain the gas density in a calibrated system. Velocity field measurements are achieved by spectrally filtering the elastically-scattered Doppler-shifted light with an absorbing molecular filter. A novel anamorphic optical collection system is used which allows optical rays from different scattering angles, that have different Doppler shifts, to be recorded separately. This is shown to obviate the need to tune the laser through the absorption to determine velocities, while retaining the ability to make spatially-resolved measurements along a line. By properly selecting the laser tuning and filter parameters, simultaneous density measurements can be made. These properties are discussed in the paper and experiments demonstrating the velocimetry capability are described.

  4. Antimicrobial durability of air filters coated with airborne Sophora flavescens nanoparticles

    International Nuclear Information System (INIS)

    Chong, Eui-seok; Hwang, Gi Byoung; Nho, Chu Won; Kwon, Bo Mi; Lee, Jung Eun; Seo, SungChul; Bae, Gwi-Nam; Jung, Jae Hee

    2013-01-01

    Airborne biological particles containing viruses, bacteria, and/or fungi can be toxic and cause infections and allergy symptoms. Recently, natural materials such as tea tree oil and Sophora flavescens have shown promising antimicrobial activity when applied as air filter media. Although many of these studies demonstrated excellent antimicrobial efficacy, only a few of them considered external environmental effects such as the surrounding humidity, temperature, and natural degradation of chemicals, all of which can affect the antimicrobial performance of these natural materials. In this study, we investigated the antimicrobial durability of air filters containing airborne nanoparticles from S. flavescens for 5 months. Antimicrobial tests and quantitative chemical analyses were performed every 30 days. Morphological changes in the nanoparticles were also evaluated by scanning electron microscopy. The major antimicrobial compounds remained stable and active for ∼ 90 days at room temperature. After about 90 days, the quantities of major antimicrobial compounds decreased noticeably with a consequent decrease in antimicrobial activity. These results are promising for the implementation of new technologies using natural antimicrobial products and provide useful information regarding the average life expectancy of antimicrobial filters using nanoparticles of S. flavescens. - Graphical abstract: Variations in (a) the concentrations of major antimicrobial chemical compounds on S. flavescens nanoparticle-coated filters: kurarinone, kuraridin, and sophoraflavanone-G and (b) the inactivation rate of antimicrobial filters as a function of time.

  5. Antimicrobial durability of air filters coated with airborne Sophora flavescens nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Chong, Eui-seok; Hwang, Gi Byoung [Center for Environment, Health, and Welfare Research, Korea Institute of Science and Technology (KIST), Hwarangno 14-gil 5, Seongbuk-gu, Seoul 136-791 (Korea, Republic of); Nho, Chu Won [Functional Food Center, Korea Institute of Science and Technology (KIST Gangneung Institute), Gangneung, Gangwon-do 210-340 (Korea, Republic of); Kwon, Bo Mi [Center for Environment, Health, and Welfare Research, Korea Institute of Science and Technology (KIST), Hwarangno 14-gil 5, Seongbuk-gu, Seoul 136-791 (Korea, Republic of); Lee, Jung Eun [Biosafety Research Team, National Institute of Environmental Research, Kyungseo-Dong, Seo-Gu, Incheon 404-170 (Korea, Republic of); Seo, SungChul [Department of Environmental Health, College of Medicine, Korea University, Anam-dong 5-ga, Seongbuk-gu, Seoul 136-701 (Korea, Republic of); Bae, Gwi-Nam, E-mail: gnbae@kist.re.kr [Center for Environment, Health, and Welfare Research, Korea Institute of Science and Technology (KIST), Hwarangno 14-gil 5, Seongbuk-gu, Seoul 136-791 (Korea, Republic of); Jung, Jae Hee, E-mail: jaehee@kist.re.kr [Center for Environment, Health, and Welfare Research, Korea Institute of Science and Technology (KIST), Hwarangno 14-gil 5, Seongbuk-gu, Seoul 136-791 (Korea, Republic of)

    2013-02-01

    Airborne biological particles containing viruses, bacteria, and/or fungi can be toxic and cause infections and allergy symptoms. Recently, natural materials such as tea tree oil and Sophora flavescens have shown promising antimicrobial activity when applied as air filter media. Although many of these studies demonstrated excellent antimicrobial efficacy, only a few of them considered external environmental effects such as the surrounding humidity, temperature, and natural degradation of chemicals, all of which can affect the antimicrobial performance of these natural materials. In this study, we investigated the antimicrobial durability of air filters containing airborne nanoparticles from S. flavescens for 5 months. Antimicrobial tests and quantitative chemical analyses were performed every 30 days. Morphological changes in the nanoparticles were also evaluated by scanning electron microscopy. The major antimicrobial compounds remained stable and active for ∼ 90 days at room temperature. After about 90 days, the quantities of major antimicrobial compounds decreased noticeably with a consequent decrease in antimicrobial activity. These results are promising for the implementation of new technologies using natural antimicrobial products and provide useful information regarding the average life expectancy of antimicrobial filters using nanoparticles of S. flavescens. - Graphical abstract: Variations in (a) the concentrations of major antimicrobial chemical compounds on S. flavescens nanoparticle-coated filters: kurarinone, kuraridin, and sophoraflavanone-G and (b) the inactivation rate of antimicrobial filters as a function of time.

  6. Experimental and Theoretical Investigation of Impinging Jet Ventilation at Different Cross Sectional Area of Supply Air Duct

    Directory of Open Access Journals (Sweden)

    Ala'a Abbas Mahdi

    2018-03-01

    Full Text Available  An experimental and computational analysis of temperature and velocity distribution in an office room have been studied. Office room of dimensions (3m x 1.75m x 3m with two cross sectional types of supply air duct in the experimental part and three different cross sectional types of supply air duct in the theoretical part is usual as a tested model. The RNG k-  turbulence model was employed to solve the governing equations numerically and validated by comparing the numerical results with experimental data. The impinging jet concept has been proposed as a new ventilation strategy for use in office and industrial buildings. The present work focuses on evaluating the performance of a new impinging jet ventilation. In a theoretical study three types of supply air duct are adopted which are square supply air duct (Type-I, semi-elliptic supply air duct (Type-II and rectangle supply air duct (Type-III for two cases of air outlet terminal height from room foot level, 0.14h (case-I & 0.1h (case-II. The third type (rectangle duct gives lowest effective and discomfort conditions when compared with the other two types. This study investigated a number of factors influencing draught discomfort and temperature stratification in an office environment equipped with impinging jet ventilation IJV. The factors considered to be: shape of the air supply device, supply airflow rate and supply air temperature. Acceptable Air Distribution Performance Index (ADPI, effective temperature, and ventilation efficiency obtained that the square cross sectional area of supply air duct at 0.1h (case-II height from foot level gives more acceptable indoor air quality and human thermal comfort when compared with the other types. Also, this type gives good air distribution system not only promotes a comfortable and healthy environment for occupants, but also contributes to energy conservation.

  7. Effect of sample digestion, air filter contamination, and post-adsorption on the analysis of trace elements in air particulate matter

    International Nuclear Information System (INIS)

    Yang, Xiao Jin; Wan, Pingyu; Foley, Roy

    2012-01-01

    Inductively coupled plasma atomic emission spectrometry and inductively coupled plasma MS are the major analytical tools for trace elements in environmental matrices, however, the underestimate of certain trace elements in analysis of air particulate matter by these two techniques has long been observed. This has been attributed to incomplete sample digestion. Here, we demonstrate that the combined effects of sample digestion, air filter impurities, and post-adsorption of the analytes contribute to the interference of the analysis. Particular attention should be paid to post-adsorption of analytes onto air filters after acid digestion. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Effect of sample digestion, air filter contamination, and post-adsorption on the analysis of trace elements in air particulate matter

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiao Jin [Department of Environment and Climate Change, Environmental Forensic and Analytical Science Section, New South Wales (Australia); Department of Applied Chemistry, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing (China); Wan, Pingyu [Department of Applied Chemistry, College of Chemical Engineering, Beijing University of Chemical Technology, Beijing (China); Foley, Roy [Department of Environment and Climate Change, Environmental Forensic and Analytical Science Section, New South Wales (Australia)

    2012-11-15

    Inductively coupled plasma atomic emission spectrometry and inductively coupled plasma MS are the major analytical tools for trace elements in environmental matrices, however, the underestimate of certain trace elements in analysis of air particulate matter by these two techniques has long been observed. This has been attributed to incomplete sample digestion. Here, we demonstrate that the combined effects of sample digestion, air filter impurities, and post-adsorption of the analytes contribute to the interference of the analysis. Particular attention should be paid to post-adsorption of analytes onto air filters after acid digestion. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  9. 42 CFR 84.149 - Type C supplied-air respirator, demand and pressure demand class; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Type C supplied-air respirator, demand and pressure demand class; minimum requirements. 84.149 Section 84.149 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT... OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.149 Type C supplied-air respirator...

  10. Electrospun Magnetic Nanoparticle-Decorated Nanofiber Filter and Its Applications to High-Efficiency Air Filtration.

    Science.gov (United States)

    Kim, Juyoung; Chan Hong, Seung; Bae, Gwi Nam; Jung, Jae Hee

    2017-10-17

    Filtration technology has been widely studied due to concerns about exposure to airborne dust, including metal oxide nanoparticles, which cause serious health problems. The aim of these studies has been to develop mechanisms for the continuous and efficient removal of metal oxide dusts. In this study, we introduce a novel air filtration system based on the magnetic attraction force. The filtration system is composed of a magnetic nanoparticle (MNP)-decorated nanofiber (MNP-NF) filter. Using a simple electrospinning system, we fabricated continuous and smooth electrospun nanofibers with evenly distributed Fe 3 O 4 MNPs. Our electrospun MNP-NF filter exhibited high particle collection efficiency (∼97% at 300 nm particle size) compared to the control filter (w/o MNPs, ∼ 68%), with a ∼ 64% lower pressure drop (∼17 Pa) than the control filter (∼27 Pa). Finally, the filter quality factors of the MNP-NF filter were 4.7 and 11.9 times larger than those of the control filter and the conventional high-efficiency particulate air filters (>99% and ∼269 Pa), respectively. Furthermore, we successfully performed a field test of our MNP-NF filter using dust from a subway station tunnel. This work suggests that our novel MNP-NF filter can be used to facilitate effective protection against hazardous metal oxide dust in real environments.

  11. Filter replacement lifetime prediction

    Science.gov (United States)

    Hamann, Hendrik F.; Klein, Levente I.; Manzer, Dennis G.; Marianno, Fernando J.

    2017-10-25

    Methods and systems for predicting a filter lifetime include building a filter effectiveness history based on contaminant sensor information associated with a filter; determining a rate of filter consumption with a processor based on the filter effectiveness history; and determining a remaining filter lifetime based on the determined rate of filter consumption. Methods and systems for increasing filter economy include measuring contaminants in an internal and an external environment; determining a cost of a corrosion rate increase if unfiltered external air intake is increased for cooling; determining a cost of increased air pressure to filter external air; and if the cost of filtering external air exceeds the cost of the corrosion rate increase, increasing an intake of unfiltered external air.

  12. Demand control on room level of the supply air temperature in an air heating and ventilation system

    DEFF Research Database (Denmark)

    Polak, Joanna; Afshari, Alireza; Bergsøe, Niels Christian

    2017-01-01

    air heating and ventilation system in a high performance single family house using BSim simulation software. The provision of the desired thermal conditions in different rooms was examined. Results show that the new control strategy can facilitate maintaining of desired temperatures in various rooms......The aim of this study was to investigate a new strategy for control of supply air temperature in an integrated air heating and ventilation system. The new strategy enables demand control of supply air temperature in individual rooms. The study is based on detailed dynamic simulations of a combined....... Moreover, this control strategy enables controlled temperature differentiation between rooms within the house and therefore provides flexibility and better balance in heat delivery. Consequently, the thermal conditions in the building can be improved....

  13. Aging assessment of nuclear air-treatment system HEPA filters and adsorbers

    International Nuclear Information System (INIS)

    Winegardner, W.K.

    1993-08-01

    A Phase I aging assessment of high-efficiency particulate air (HEPA) filters and activated carbon gas adsorption units (adsorbers) was performed by the Pacific Northwest Laboratory (PNL) as part of the US Nuclear Regulatory Commission's (NRC) Nuclear Plant Aging Research (NPAR) Program. Information concerning design features; failure experience; aging mechanisms, effects, and stressors; and surveillance and monitoring methods for these key air-treatment system components was compiled. Over 1100 failures, or 12 percent of the filter installations, were reported as part of a Department of Energy (DOE) survey. Investigators from other national laboratories have suggested that aging effects could have contributed to over 80 percent of these failures. Tensile strength tests on aged filter media specimens indicated a decrease in strength. Filter aging mechanisms range from those associated with particle loading to reactions that alter properties of sealants and gaskets. Low radioiodine decontamination factors associated with the Three Mile Island (TMI) accident were attributed to the premature aging of the carbon in the adsorbers. Mechanisms that can lead to impaired adsorber performance include oxidation as well as the loss of potentially available active sites as a result of the adsorption of pollutants. Stressors include heat, moisture, radiation, and airborne particles and contaminants

  14. High Efficiency Particulate Air (HEPA) Filter Generation, Characterization, and Disposal Experiences at the Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Coffey, D. E.

    2002-01-01

    High Efficiency Particulate Air filtration is an essential component of the containment and ventilation systems supporting the research and development activities at the Oak Ridge National Laboratory. High Efficiency Particulate Air filters range in size from 7.6cm (3 inch) by 10.2 cm (4 inch) cylindrical shape filters to filter array assemblies up to 2.1 m (7 feet) high by 1.5 m (5 feet) wide. Spent filters are grouped by contaminates trapped in the filter media and become one of the components in the respective waste stream. Waste minimization and pollution prevention efforts are applied for both radiological and non-radiological applications. Radiological applications include laboratory hoods, glove boxes, and hot cells. High Efficiency Particulate Air filters also are generated from intake or pre-filtering applications, decontamination activities, and asbestos abatement applications. The disposal avenues include sanitary/industrial waste, Resource Conservation and Recovery Act and Toxic Substance Control Act, regulated waste, solid low-level waste, contact handled transuranic, and remote handled transuranic waste. This paper discusses characterization and operational experiences associated with the disposal of the spent filters across multiple applications

  15. Sensory Pollution from Bag Filters, Carbon Filters and Combinations

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Clausen, Geo; Weschler, Charles J.

    2008-01-01

    by an upstream pre-filter (changed monthly), an EU7 filter protected by an upstream activated carbon (AC) filter, and EU7 filters with an AC filter either downstream or both upstream and downstream. In addition, two types of stand-alone combination filters were evaluated: a bag-type fiberglass filter...... that contained AC and a synthetic fiber cartridge filter that contained AC. Air that had passed through used filters was most acceptable for those sets in which an AC filter was used downstream of the particle filter. Comparable air quality was achieved with the stand-alone bag filter that contained AC...

  16. Purification yields of forced air filters for radioactive breath protection

    International Nuclear Information System (INIS)

    Landman, E.B.

    1986-01-01

    Air filters for breath protection were tested as to purification yield using the in-situ DOP testing method. Only some of them satisfied the requirements made by the authors. Requirements, testing methods, experimental set-up and results are presented. (G.J.P.)

  17. Washable antimicrobial polyester/aluminum air filter with a high capture efficiency and low pressure drop.

    Science.gov (United States)

    Choi, Dong Yun; Heo, Ki Joon; Kang, Juhee; An, Eun Jeong; Jung, Soo-Ho; Lee, Byung Uk; Lee, Hye Moon; Jung, Jae Hee

    2018-06-05

    Here, we introduce a reusable bifunctional polyester/aluminum (PET/Al) air filter for the high efficiency simultaneous capture and inactivation of airborne microorganisms. Both bacteria of Escherichia coli and Staphylococcus epidermidis were collected on the PET/Al filter with a high efficiency rate (∼99.99%) via the electrostatic interactions between the charged bacteria and fibers without sacrificing pressure drop. The PET/Al filter experienced a pressure drop approximately 10 times lower per thickness compared with a commercial high-efficiency particulate air filter. As the Al nanograins grew on the fibers, the antimicrobial activity against airborne E. coli and S. epidermidis improved to ∼94.8% and ∼96.9%, respectively, due to the reinforced hydrophobicity and surface roughness of the filter. Moreover, the capture and antimicrobial performances were stably maintained during a cyclic washing test of the PET/Al filter, indicative of its reusability. The PET/Al filter shows great potential for use in energy-efficient bioaerosol control systems suitable for indoor environments. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    International Nuclear Information System (INIS)

    Barnett, J.M.

    2008-01-01

    Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity of particulate radioactive air samples. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor(reg s ign) 3000) used at PNNL for self absorption effects. There were two methods used in the study, (1) to compare the radioactivity concentration by direct gas-flow proportional counting of the filter to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection and (2) to evaluate sample filters by high resolution visual/infrared microscopy to determine the depth of material loading on or in the filter fiber material. Sixty samples were selected from the archive for acid digestion in the first method and about 30 samples were selected for high resolution visual/infrared microscopy. Mass loading effects were also considered. From the sample filter analysis, large error is associated with the average self absorption factor, however, when the data is compared directly one-to-one, statistically, there appears to be good correlation between the two analytical methods. The mass loading of filters evaluated was <0.2 mg cm-2 and was also compared against other published results. The microscopy analysis shows the sample material remains on the top of the filter paper and does not imbed into the filter media. Results of the microscopy evaluation lead to the conclusion that there is not a mechanism for significant self absorption. The overall conclusion is that self-absorption is not a significant factor in the analysis of filters used at PNNL for radioactive air stack sampling of radionuclide particulates and that an applied correction factor is conservative in determining overall sample activity. A new self absorption factor of 1.0 is recommended

  19. Particle loading rates for HVAC filters, heat exchangers, and ducts.

    Science.gov (United States)

    Waring, M S; Siegel, J A

    2008-06-01

    The rate at which airborne particulate matter deposits onto heating, ventilation, and air-conditioning (HVAC) components is important from both indoor air quality (IAQ) and energy perspectives. This modeling study predicts size-resolved particle mass loading rates for residential and commercial filters, heat exchangers (i.e. coils), and supply and return ducts. A parametric analysis evaluated the impact of different outdoor particle distributions, indoor emission sources, HVAC airflows, filtration efficiencies, coils, and duct system complexities. The median predicted residential and commercial loading rates were 2.97 and 130 g/m(2) month for the filter loading rates, 0.756 and 4.35 g/m(2) month for the coil loading rates, 0.0051 and 1.00 g/month for the supply duct loading rates, and 0.262 g/month for the commercial return duct loading rates. Loading rates are more dependent on outdoor particle distributions, indoor sources, HVAC operation strategy, and filtration than other considered parameters. The results presented herein, once validated, can be used to estimate filter changing and coil cleaning schedules, energy implications of filter and coil loading, and IAQ impacts associated with deposited particles. The results in this paper suggest important factors that lead to particle deposition on HVAC components in residential and commercial buildings. This knowledge informs the development and comparison of control strategies to limit particle deposition. The predicted mass loading rates allow for the assessment of pressure drop and indoor air quality consequences that result from particle mass loading onto HVAC system components.

  20. Problems in creation of modern air inlet filters of power gas turbine plants in Russia and methods of their solving

    Science.gov (United States)

    Mikhaylov, V. E.; Khomenok, L. A.; Sherapov, V. V.

    2016-08-01

    The main problems in creation and operation of modern air inlet paths of gas turbine plants installed as part of combined-cycle plants in Russia are presented. It is noted that design features of air inlet filters shall be formed at the stage of the technical assignment not only considering the requirements of gas turbine plant manufacturer but also climatic conditions, local atmospheric air dustiness, and a number of other factors. The recommendations on completing of filtration system for air inlet filter of power gas turbine plants depending on the facility location are given, specific defects in design and experience in operation of imported air inlet paths are analyzed, and influence of cycle air preparation quality for gas turbine plant on value of operating expenses and cost of repair works is noted. Air treatment equipment of various manufacturers, influence of aerodynamic characteristics on operation of air inlet filters, features of filtration system operation, anti-icing system, weather canopies, and other elements of air inlet paths are considered. It is shown that nonuniformity of air flow velocity fields in clean air chamber has a negative effect on capacity and aerodynamic resistance of air inlet filter. Besides, the necessity in installation of a sufficient number of differential pressure transmitters allowing controlling state of each treatment stage not being limited to one measurement of total differential pressure in the filtration system is noted in the article. According to the results of the analysis trends and methods for modernization of available equipment for air inlet path, the importance of creation and implementation of new technologies for manufacturing of filtering elements on sites of Russia within the limits of import substitution are given, and measures on reliability improvement and energy efficiency for air inlet filter are considered.

  1. PubMed search filters for the study of putative outdoor air pollution determinants of disease

    OpenAIRE

    Curti, Stefania; Gori, Davide; Di Gregori, Valentina; Farioli, Andrea; Baldasseroni, Alberto; Fantini, Maria Pia; Christiani, David C; Violante, Francesco S; Mattioli, Stefano

    2016-01-01

    Objectives: Several PubMed search filters have been developed in contexts other than environmental. We aimed at identifying efficient PubMed search filters for the study of environmental determinants of diseases related to outdoor air pollution. Methods: We compiled a list of Medical Subject Headings (MeSH) and non-MeSH terms seeming pertinent to outdoor air pollutants exposure as determinants of diseases in the general population. We estimated proportions of potentially pertinent articles to...

  2. Inverse Problem of Air Filtration of Nanoparticles: Optimal Quality Factors of Fibrous Filters

    Directory of Open Access Journals (Sweden)

    Dahua Shou

    2015-01-01

    Full Text Available Application of nanofibers has become an emerging approach to enhance filtration efficiency, but questions arise about the decrease in Quality factor (QF for certain particles due to the rapidly increasing pressure drop. In this paper, we theoretically investigate the QF of dual-layer filters for filtration of monodisperse and polydisperse nanoparticles. The inverse problem of air filtration, as defined in this work, consists in determining the optimal construction of the two-layer fibrous filter with the maximum QF. In comparison to a single-layer substrate, improved QF values for dual-layer filters are found when a second layer with proper structural parameters is added. The influences of solidity, fiber diameter, filter thickness, face velocity, and particle size on the optimization of QF are studied. The maximum QF values for realistic polydisperse particles with a lognormal size distribution are also found. Furthermore, we propose a modified QF (MQF accounting for the effects of energy cost and flow velocity, which are significant in certain operations. The optimal MQF of the dual-layer filter is found to be over twice that of the first layer. This work provides a quick tool for designing and optimizing fibrous structures with better performance for the air filtration of specific nanoparticles.

  3. Experimental study on airflow fluctuation characteristic of an underfloor air supply terminal unit

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinping [School of Electric Power, South China University of Technology, Guangzhou 510640 (China); State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510640 (China); Wu, Yanfang [Design Institute of Guangzhou Metro Corporation, Guangzhou 510010 (China)

    2010-11-15

    In order to investigate dynamic characteristic of underfloor air supply terminal unit, an IFV900A hot-wire anemometer was used to measure the corresponding velocity field. Turbulence intensity and power spectrum density exponent of air velocity signal were analyzed. The result showed that the outlet velocity distribution of underfloor air supply terminal unit was uniform. With increment of height, the velocity distribution trends to be uniform. Two velocity attenuation regions appear during airflow development. Turbulence intensity changes obviously with height. It is lower than that of mechanical wind. Turbulence intensity goes up with the increment of jetting distance. Power spectrum density exponent trends to the value of natural wind with increase of jetting distance and decrease of wind velocity. The exponent value approaches to the value of typical natural wind for the air velocity is 0.5 m/s under high supply air rate. With airflow diffusion, the fluctuation characteristic of airflow varies obviously with the jetting direction. The fluctuation characteristic of airflow changes to that of natural wind with the increase of height which can improve comfort of indoor environment. (author)

  4. Data Assimilation in Air Contaminant Dispersion Using a Particle Filter and Expectation-Maximization Algorithm

    Directory of Open Access Journals (Sweden)

    Rongxiao Wang

    2017-09-01

    Full Text Available The accurate prediction of air contaminant dispersion is essential to air quality monitoring and the emergency management of contaminant gas leakage incidents in chemical industry parks. Conventional atmospheric dispersion models can seldom give accurate predictions due to inaccurate input parameters. In order to improve the prediction accuracy of dispersion models, two data assimilation methods (i.e., the typical particle filter & the combination of a particle filter and expectation-maximization algorithm are proposed to assimilate the virtual Unmanned Aerial Vehicle (UAV observations with measurement error into the atmospheric dispersion model. Two emission cases with different dimensions of state parameters are considered. To test the performances of the proposed methods, two numerical experiments corresponding to the two emission cases are designed and implemented. The results show that the particle filter can effectively estimate the model parameters and improve the accuracy of model predictions when the dimension of state parameters is relatively low. In contrast, when the dimension of state parameters becomes higher, the method of particle filter combining the expectation-maximization algorithm performs better in terms of the parameter estimation accuracy. Therefore, the proposed data assimilation methods are able to effectively support air quality monitoring and emergency management in chemical industry parks.

  5. Aspergillus prevalence in air conditioning filters from vehicles: taxis for patient transportation, forklifts, and personal vehicles.

    Science.gov (United States)

    Viegas, Carla; Moreira, Ricardo; Faria, Tiago; Caetano, Liliana Aranha; Carolino, Elisabete; Gomes, Anita Quintal; Viegas, Susana

    2018-05-04

    The frequency and importance of Aspergillus infections is increasing worldwide. This study aimed to assess the occupational exposure of forklifts and taxi drivers to Aspergillus spp. Nineteen filters from air conditioning system of taxis, 17 from forklifts and 37 from personal vehicles were assessed. Filters extract were streaked onto MEA, DG18 and in azole-supplemented media. Real-time quantitative PCR amplification of selected Aspergillus species-complex was also performed. Forklifts filter samples presented higher median values. Aspergillus section Nigri was the most observed in forklifts filters in MEA (28.2%) and in azole-supplemented media. DNA from Aspergillus sections Fumigati and Versicolores was successfully amplified by qPCR. This study enlightens the added value of using filters from the air conditioning system to assess Aspergillus spp. occupational exposure. Aspergillus azole resistance screening should be included in future occupational exposure assessments.

  6. Resistance of HEPA filter separator materials to humid air--hydrogen fluoride--fluorine environments

    International Nuclear Information System (INIS)

    Weber, C.W.; Petit, G.S.; Woodfin, S.B.

    1977-01-01

    The U. S. Energy Research and Development Administration (ERDA) is interested in the development of a high-efficiency particulate air (HEPA) filter that is resistant to such corrosive reagents as hydrogen fluoride (HF) and fluorine (F 2 ) in air environments of normal relative humidity (about 50% RH). Several types of separator materials are used in the fabrication of commercial filters. The basic types of separator materials are asbestos, Kraft paper, plastic, and aluminum. At the request of the ERDA Division of Operational Safety, the different types of separator materials have been evaluated for their resistance to corrosive attack by HF and F 2 . The separator materials were dynamically tested in the 4-stage multiunit tester located in the Oak Ridge Gaseous Diffusion Plant laboratories. This is the system previously used in the evaluation of the Herty Foundation filter paper samples. Concurrent with the testing of filter media for its resistance to HF and F 2 , another component of the completed filter, the separator, was tested. All samples were exposed to a constant air flow (50% RH) of 32 liters/min, at 100 0 F, containing 900 ppM HF and 300 ppM F 2 . Exposure periods varied from 2 to 1000 h; however, the longer exposures were made only on the stronger candidates. Test results show the plastic and aluminum separator materials to be superior to the other types in resistance to HF and F 2 . The asbestos separators disintegrated after a relatively short exposure time; the Kraft paper types were the next weakest. The Clear Plastic S was the best performer of the plastics tested

  7. THE EFFECT OF THE REYNOLDS NUMBER OF AIR FLOW TO THE PARTICLE COLLECTION EFFICIENCY OF A FIBROUS FILTER MEDIUM WITH CYLINDRICAL SECTION

    Directory of Open Access Journals (Sweden)

    George P. Kouropoulos

    2014-01-01

    Full Text Available At this study an attempt for the theoretical approach of the Re ynolds number effect of air flow to the particle collection efficiency of a fibrous fil ter with cylindrical section will be made. Initially, a report of the air filtration models to fibrous filter media will be presented along with an explanation of both the parameters and the physical quantities which govern the air filtration process. Furthermore, the resul ting equation from the mathematical model will be applied to a real filter medium and the characteristic curves of filter efficiency will be drawn. The change of a filter medi um efficiency with regard to the Reynolds number of air flow that passes through the filt er, derived from the curves, will be studied. The general conclusion that we have is that as the Reynolds number of filtered air increases, the collection efficiency of the filter decreases.

  8. Comparison of direct alpha spectrometry and neutron activation analysis of aerosol filters for determination of workplace thorium air concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Hoetzl, H.; Winkler, R. [Institut fuer Strahlenschutz, Oberschleibheim (Germany); Riedmann, W.; Weinmueller, K. [Strahlenschutz und Isotopentechnik, Muenchen (Germany)

    1996-05-01

    Direct alpha spectrometry with three different filter types was investigated for the determination of thorium air concentrations at workplaces in the manufacturing process of discharge lamps containing thoriated tungsten electrodes. The method was compared with neutron activation analysis over an activity range of five orders of magnitude. Within the experimental limits of error, both methods were found to be comparable with respect to sensitivity and accuracy. The advantage of direct alpha spectrometry, however, is that it is less laborious than neutron activation analysis and that it supplies information on the degree of radioactive equilibrium of the thorium series, which is important with regard to the estimation of dose. 20 refs., 2 figs., 1 tab.

  9. Application of ground-to-air heat exchanger for preheating of supply air

    Science.gov (United States)

    Sorokins, Juris; Borodinecs, Anatolijs; Zemitis, Jurgis

    2017-10-01

    This study focuses on assessing the contribution of the passive ground-coupled air heat exchanger system to decreasing the energy consumption of air conditioning and ventilation systems for office buildings in the Latvian climate conditions. The theoretical part of the thesis deals with methods of office building ventilation, supply air preheating and heat recovery as well as particularities of using ground-coupled air heat exchangers, their design parameters and their joint impact on the thermal performance. The engineering project part includes a ventilation system for an office building with an integrated ground-coupled air heat exchanger. By simulating energy consumption of the ventilation system for a duration of one year, the thesis analyzes the contribution of the heat exchanger to the overall energy consumption, which totals 9.53 MWh and 4.02 MWh a year, according to the desired parameters of the indoor climate. The possible alternative heat recovery solutions are investigated to reach by European Regional Development Fund project Nr.1.1.1.1/16/A/048 “NEARLY ZERO ENERGY SOLUTIONS FOR UNCLASSIFIED BUILDINGS”.

  10. The sampling of sulfur dioxide in air with impregnated filter paper

    NARCIS (Netherlands)

    Huygen, C.

    1963-01-01

    A method is suggested for the sampling of sulfur dioxide in air with impregnated filter paper instead of bubblers. The best aqueous impregnating solution contained potassium hydroxide with glycerol or triethanolamine. The possibilities and limitations of the method are discussed. High collection

  11. A novel complex air supply model for indoor air quality control via the occupant micro-environment demand ventilation

    International Nuclear Information System (INIS)

    Yang, Jie; Zhou, Bo; Jin, Maozhu; Wang, Jun; Xiong, Feng

    2016-01-01

    Protection of indoor air quality and human health can be achieved via ventilation, which has becomes one of the most important tasks for sustainable buildings. This approach also requires highly efficient and energy saving methods for modern building ventilations consisting of a set of parameters of the complex indoor system. Therefore, the advancement in understanding the characteristics of various ventilation methods is highly necessary. This study presents one novel air supply model for the complex occupant micro-environment demand control ventilations, to analyze the efficiency of various ventilation types. This model is established primarily according to the momentum and mass conservations, and goal of occupant micro-environment demand, which is a complex system with the characteristics of diversity and dynamic variation. As for different occupant densities, characteristics of outdoor air supply for controlling gaseous pollutant and three basic features of outdoor airflow supply reaching occupant micro-environment were obtained. This research shows that for various types of occupant density and storey height, the rising and descending rates of the demand outdoor airflow in mixing ventilation are higher than those under displacement ventilation conditions. In addition, since the structure is better designed and sewage flow is more efficient, the mixing ventilation also requires a much higher peak demand outdoor airflow than its counterpart. The increase of storey height will lead to a decline of pollutants in the breathing zone and the demand outdoor airflow. Fluctuations of air flow diffusion caused by the change of occupant density in architectural space, will lead to variations of outdoor airflow reaching occupant micro-environment. Accordingly, it would lead to the different peak values of demand outdoor airflow, and the difference becomes even significant if the occupant density increases. The variations of the air supply and fraction of air reaching the

  12. The sampling of hydrogen sulfide in air with impregnated filter paper

    NARCIS (Netherlands)

    Huygen, C.

    1964-01-01

    A method is proposed for the quantitative collection of hydrogen sulfide in air on impregnated filter paper. An aqueous solution of potassium hydroxide, potassium zincate and glycerol is used as impregnating fluid. The stability of the collected sulfide and the efficiency of collection at different

  13. Semiconductor cleaning liquid delivery system and its filter; Handotaiyo seijo yakueki kyokyu system to filter

    Energy Technology Data Exchange (ETDEWEB)

    Saito, T. [Kanto Chemical Co. Inc., Tokyo (Japan); Hayama, H.; Sakka, T. [Nitto Denko Corp., Osaka (Japan)

    1994-11-30

    Most of chemicals used for producing semiconductors are supplied automatically by a chemical delivery system to production devices. This paper explains the current status and the trends of the system. This system supplies the chemicals in the order of a tank lorry, a storage tank, a supply tank, a filter and a production device, and the transfer is performed receiving a supply signal from the supply tank and the production device. The transfer may be done through a dilution equipment. Filters currently used have membrane pore sizes of 0.2 to 0.1 microns as prefilters, and 0.1 to 0.05 microns as final filters. Chemicals used are diverse and can be divided into acid-, alkaline-, and solvent-based groups. Fluorine resin filters are used for acid- and alkaline-resistant applications, and SUS/fluorine resin filters for solvent-resistant applications. Use of large-sized filters of element construction with a membrane area of 1 m{sup 2} class is increasing recently in addition to selection from a performance viewpoint, including particle removing performance. 9 figs., 7 tabs.

  14. Use of dust fall filters as passive samplers for metal concentrations in air for communities near contaminated mine tailings.

    Science.gov (United States)

    Beamer, P I; Sugeng, A J; Kelly, M D; Lothrop, N; Klimecki, W; Wilkinson, S T; Loh, M

    2014-05-01

    Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites.

  15. Results of Self-Absorption Study on the Versapor 3000 Filters for Radioactive Particulate Air Sampling

    International Nuclear Information System (INIS)

    Barnett, J.M.; Cullinan, Valerie I.; Barnett, Debra S.; Trang-Le, Truc LT; Bliss, Mary; Greenwood, Lawrence R.; Ballinger, Marcel Y.

    2009-01-01

    Since the mid-1980s, Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as the correction factor for self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. This value accounts for activity that cannot be detected by direct counting of alpha and beta particles. Emissions can be degraded or blocked by filter fibers for particles buried in the filter material or by inactive dust particles collected with the radioactive particles. These filters are used for monitoring air emissions from PNNL stacks for radioactive particles. This paper describes an effort to re-evaluate self-absorption effects in particulate radioactive air sample filters (Versapor(reg s ign) 3000, 47 mm diameter) used at PNNL. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Filter ratios were calculated by dividing the initial counts by the post-digestion counts with the expectation that post-digestion counts would be higher because digestion would expose radioactivity embedded in the filter in addition to that on top of the filter. Contrary to expectations, the post digestion readings were almost always lower than initial readings and averaged approximately half the initial readings for both alpha and beta activity. Before and after digestion readings appeared to be related to each other, but with a low coefficient of determination (R 2 ) value. The ratios had a wide range of values indicating that this method did not provide sufficient precision to quantify

  16. Concentric Split Flow Filter

    Science.gov (United States)

    Stapleton, Thomas J. (Inventor)

    2015-01-01

    A concentric split flow filter may be configured to remove odor and/or bacteria from pumped air used to collect urine and fecal waste products. For instance, filter may be designed to effectively fill the volume that was previously considered wasted surrounding the transport tube of a waste management system. The concentric split flow filter may be configured to split the air flow, with substantially half of the air flow to be treated traveling through a first bed of filter media and substantially the other half of the air flow to be treated traveling through the second bed of filter media. This split flow design reduces the air velocity by 50%. In this way, the pressure drop of filter may be reduced by as much as a factor of 4 as compare to the conventional design.

  17. The effect of ambient ozone and humidity on the performance of nylon and Teflon filters used in ambient air monitoring filter-pack systems

    Science.gov (United States)

    PE Padgett

    2010-01-01

    Nylon and Teflon filter media are frequently used for monitoring ambient air pollutants. These media are subject to many environmental factors that may influence adsorption and retention of particulate and gaseous nitrogenous pollutants. This study evaluated the effects of ozone and humidity on the efficacy of nylon and Teflon filters used in the US dry deposition...

  18. Evaluation of the effect of media velocity on filter efficiency and most penetrating particle size of nuclear grade high-efficiency particulate air filters.

    Science.gov (United States)

    Alderman, Steven L; Parsons, Michael S; Hogancamp, Kristina U; Waggoner, Charles A

    2008-11-01

    High-efficiency particulate air (HEPA) filters are widely used to control particulate matter emissions from processes that involve management or treatment of radioactive materials. Section FC of the American Society of Mechanical Engineers AG-1 Code on Nuclear Air and Gas Treatment currently restricts media velocity to a maximum of 2.5 cm/sec in any application where this standard is invoked. There is some desire to eliminate or increase this media velocity limit. A concern is that increasing media velocity will result in higher emissions of ultrafine particles; thus, it is unlikely that higher media velocities will be allowed without data to demonstrate the effect of media velocity on removal of ultrafine particles. In this study, the performance of nuclear grade HEPA filters, with respect to filter efficiency and most penetrating particle size, was evaluated as a function of media velocity. Deep-pleat nuclear grade HEPA filters (31 cm x 31 cm x 29 cm) were evaluated at media velocities ranging from 2.0 to 4.5 cm/sec using a potassium chloride aerosol challenge having a particle size distribution centered near the HEPA filter most penetrating particle size. Filters were challenged under two distinct mass loading rate regimes through the use of or exclusion of a 3 microm aerodynamic diameter cut point cyclone. Filter efficiency and most penetrating particle size measurements were made throughout the duration of filter testing. Filter efficiency measured at the onset of aerosol challenge was noted to decrease with increasing media velocity, with values ranging from 99.999 to 99.977%. The filter most penetrating particle size recorded at the onset of testing was noted to decrease slightly as media velocity was increased and was typically in the range of 110-130 nm. Although additional testing is needed, these findings indicate that filters operating at media velocities up to 4.5 cm/sec will meet or exceed current filter efficiency requirements. Additionally

  19. Viral Penetration of High Efficiency Particulate Air (HEPA) Filters

    Science.gov (United States)

    2007-02-01

    PVC tubing (Excelon® RNT,US Plastics, Lima , Ohio). Each path runs through a test article and thence through one AGI-30 all-glass impingers (Chemglass...a mechanical flow meter (Blue–White 400, Huntington Beach , California, or PMR1-101346, Cole– Parmer, Vernon Hills, Illinois). At the end of the...fibrous Filters." Air Pollution Control Association 30(4): 377-381. Leenders, G. J. M. and J. H. Stadhouders (1980s). "Effectiveness of HEPA

  20. Numerical study of canister filters with alternatives filter cap configurations

    Science.gov (United States)

    Mohammed, A. N.; Daud, A. R.; Abdullah, K.; Seri, S. M.; Razali, M. A.; Hushim, M. F.; Khalid, A.

    2017-09-01

    Air filtration system and filter play an important role in getting a good quality air into turbo machinery such as gas turbine. The filtration system and filter has improved the quality of air and protect the gas turbine part from contaminants which could bring damage. During separation of contaminants from the air, pressure drop cannot be avoided but it can be minimized thus helps to reduce the intake losses of the engine [1]. This study is focused on the configuration of the filter in order to obtain the minimal pressure drop along the filter. The configuration used is the basic filter geometry provided by Salutary Avenue Manufacturing Sdn Bhd. and two modified canister filter cap which is designed based on the basic filter model. The geometries of the filter are generated by using SOLIDWORKS software and Computational Fluid Dynamics (CFD) software is used to analyse and simulates the flow through the filter. In this study, the parameters of the inlet velocity are 0.032 m/s, 0.063 m/s, 0.094 m/s and 0.126 m/s. The total pressure drop produce by basic, modified filter 1 and 2 is 292.3 Pa, 251.11 Pa and 274.7 Pa. The pressure drop reduction for the modified filter 1 is 41.19 Pa and 14.1% lower compared to basic filter and the pressure drop reduction for modified filter 2 is 17.6 Pa and 6.02% lower compared to the basic filter. The pressure drops for the basic filter are slightly different with the Salutary Avenue filter due to limited data and experiment details. CFD software are very reliable in running a simulation rather than produces the prototypes and conduct the experiment thus reducing overall time and cost in this study.

  1. The efficiency of Whatman Type ACG/B filter papers for methyl iodine retention in air

    International Nuclear Information System (INIS)

    Davis, R.E.; Williams, J.M.E.

    1965-11-01

    Experiments are described in which charcoal impregnated glass fibre filter papers Type ACG/B were exposed to methyl iodide vapour and the penetration determined for iodide loadings ranging from 2 x 10 - 7 to 2x10 - 1 μg/cm 2 of filter area. Air was subsequently passed through the filters, and at intervals the amount of methyl iodide remaining on them was determined. Penetrations during loading varied from 30% to 80%, but after 10 minutes elution all filters retained less than 5% of the methyl iodide originally present. (author)

  2. Air-cleaning devices for vented filtered LMFBR containment

    International Nuclear Information System (INIS)

    Muhlestein, L.D.; Hilliard, R.K.

    1982-07-01

    An effort lasting several years is summarized which evaluated, developed and tested air cleaning devices for potential use in breeder reactor containment venting applications. State-of-technology evaluations were completed for both a hypothetical head release accident and a primary vessel melt-through accident. Commercially available systems or components were tested which included HEPA filters, sand and gravel beds, and aqueous scrubbers. Large-scale demonstration tests were completed and results are presented for two- and three-stage conventional aqueous scrubber systems; and for a newly developed passive, submerged gravel scrubber

  3. Modelling of air flows in pleated filters and of their clogging by solid particles; Modelisation des ecoulements d'air et du colmatage des filtres plisses par des aerosols solides

    Energy Technology Data Exchange (ETDEWEB)

    Del Fabbro, L

    2002-07-01

    The devices of air cleaning against particles are widely spread in various branches of industry: nuclear, motor, food, electronic,...; among these devices, numerous are constituted by pleated porous media to increase the surface of filtration and thus to reduce the pressure drop, for given air flow. The objective of our work is to compensate a lack evident of knowledge on the evolution of the pressure drop of pleated filter during the clogging and to deduct a modelling from it, on the basis of experiments concerning industrial filters of nuclear and car types. The obtained model is a function of characteristics of the filtering medium and pleats, of the characteristics of solid particles deposited on the filter, of the mass of particles and of the aeraulic conditions of air flow. It also depends on data on the clogging of flat filters of equivalent medium. To elaborate this model of pressure drop, an initial stage was carried out in order to characterize, experimentally and numerically, the pressure drop and the distribution of air flow in clean pleated filters of nuclear (high efficiency particulate air filter, in fiberglasses) and car (mean efficiency filter, in fibers of cellulose) types. The numerical model allowed to understand the fundamental role played by the aeraulic resistance of the filtering medium. From an non-dimensional approach, we established a semi-empirical model of pressure drop for a clean pleated filter valid for both studied types of medium; this model is used of first base for the development of the final model of clogging. The study of the clogging of the filters showed the complexity of the phenomenon dependent mainly on a reduction of the surface of filtration. This observation brings us to propose a clogging of pleated filters in three phases. Both first phases are similar in those observed for flat filters, while last phase corresponds to a reduction of the surface of filtration and leads a strong increase of the filter pressure drop

  4. Air Force Supply Management Analysis of Activity Groups Financial Reports, Prices, and Cash Management

    National Research Council Canada - National Science Library

    1998-01-01

    The Air Force supply management activity group provides about two million types of inventory items, including weapon system spare parts, fuels, and medical-dental supplies, to customers which consist...

  5. Study of loading/air back-pulse cleaning cycles on the performance of ceramic membrane filters

    International Nuclear Information System (INIS)

    Waggoner, Charles; Alderman, Steven; Parsons, Michael; Hogoncamp, Kristina; Alderman, Steven

    2007-01-01

    Available in abstract form only. Full text of publication follows: The most commonly identified threats to conventional glass fiber HEPA filter performance are moisture and rapid blinding of filters by smoke. Regenerable filter media composed of ceramics or sintered metal can be utilized as pre-filters to protect the more vulnerable glass fiber HEPA filters in the event of upset conditions. Additionally, used in a pre-filtering application, the use of these regenerable filters can potentially extend the lifetime of conventional units. A series of tests have been conducted using CeraMem ceramic membrane filters in an effort to evaluate their performance after repeated loading and air back pulse cleaning. This was done in an effort to access filter performance after repeated loading/cleaning cycles. The filters were loaded using a solid potassium chloride aerosol challenge. The filters were evaluated for pressure drop and filtering efficiency changes from one cleaning cycle to the next. Additionally, the particle size distribution of the aerosol penetrating the filters was measured. (authors)

  6. Development and evaluation of a plant-based air filter system for ...

    African Journals Online (AJOL)

    We investigated a novel plant-based air filter system for bacterial growth control. The volatile components released from the experimental plant (Cupressus macrocarpa) were used as the basis of the bacterial growth control and inhibition. We monitored the effect of light on the gas exhausted from the system, and we found ...

  7. 42 CFR 84.157 - Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum...

    Science.gov (United States)

    2010-10-01

    ... test; Type C supplied-air respirator, pressure-demand class; minimum requirements. (a) The static... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test; Type C supplied-air respirator, pressure-demand class; minimum requirements. 84.157 Section 84.157 Public Health PUBLIC HEALTH...

  8. 42 CFR 84.156 - Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements.

    Science.gov (United States)

    2010-10-01

    ... C supplied-air respirator, demand class; minimum requirements. (a) Inhalation resistance shall not... 42 Public Health 1 2010-10-01 2010-10-01 false Airflow resistance test; Type C supplied-air respirator, demand class; minimum requirements. 84.156 Section 84.156 Public Health PUBLIC HEALTH SERVICE...

  9. Method for cleaning the filter pockets of dust gas filter systems

    Energy Technology Data Exchange (ETDEWEB)

    Margraf, A

    1975-05-07

    The invention deals with a method to clean filter pockets filled with dust gas. By a periodic to and fro air jet attached to a scavenging blower, a pulsed fluttering movement of the filter surface is obtained which releases the outer layers of dust. The charging of the filter pockets with scavenging air to clean the filter material can be carried out immediately on the pulsed admission with suitable time control.

  10. Standard specification for high efficiency particulate air filters. Revision No. 2

    International Nuclear Information System (INIS)

    Porter, F.E.

    1976-01-01

    This specification covers the requirements for four types and four sizes of high efficiency particulate air filters, assembled with or without separators and gaskets. Types include Fire Resistant and Moisture Resistant; Hydrogen Fluoride Fume (HF) Resistant; Fire Resistant and Moisture Resistant and Chemical Resistant; and Fire Resistant and Moisture Resistant, High Temperature and High Humidity

  11. Influence of environmental characteristics and climatic factors on mites in the dust of air-conditioner filters.

    Science.gov (United States)

    Wu, J; Liu, Z G; Ran, P X; Wang, B

    2009-12-01

    To investigate mites in the dust of air-conditioner filters (MACF) in China, a total of 652 dust samples were collected from six cities: Guangzhou (n = 129), Nanchang (n = 127), Shanghai (n = 113), Xian (n = 93), Beijing (n = 93), and Shenyang (n = 79). Tarsonemus granarius was the most dominant species (87.2%). Dermatophagoides pteronyssinus and Dermatophagoides farinae only represented 7.0 and 3.0% of total mites, respectively. With latitude increasing, both mite occurrence rate (P air-conditioner age, utilization time and power. Wall and window type air-conditioner had higher risk of finding MACF than the floor type air-conditioner. As far as the cleaning interval time of ACF was concerned, higher risk ratio and the highest density of MACF were found in the time stage of >3, air-conditioner filters are potential indoor threat to asthma and allergy sufferers. In this study, we find that the storage mite Tarsonemus granarius is the predominant species of mites in the dust of air-conditioner filters (MACF). Thus, the possible clinical importance of T. granarius should cause more our attentions in the future. The abundance and distribution of MACF are also found significantly varied in different climatic regions of China. When we try to assess the possible risk of MACF, more attentions should be focused on subtropical region than temperate region. The influence analysis of environmental characteristics on the prevalence of MACF will shed light on the establishment of mite control strategy and the design of mite defense air-conditioner.

  12. [Verification of bacteriological safety of PCM 40 air conditioner].

    Science.gov (United States)

    Dumas, J L; Ducel, G; Rouge, J C

    1991-01-01

    This study assessed the bacteriological safety of the bedside air conditioner PCM 40 (Howorth Airtech), used for prevention of intraoperative hypothermia, by blowing filtered warm air through a special mattress. The 3 microns bacterial filter of the device released 2,968 +/- 5,618 particles of diameter less than 3 microns per m3 of room air, containing 78,798 +/- 37,243 of such particles per m3. The amount of bacteries in the air pulsed from the mattress was 30 +/- 41 cfu/m3 vs 120 cfu/m3 in the ambient air and in the hot air supply tubing it reached 6 +/- 5 cfu/m3 vs 175 +/- 77 cfu/m3. It is concluded that bacteriological data do not contra-indicate the use of this air conditioner in the operating theater. The only limitations for use are the position (prone or lateral position) and type of surgery (neurosurgery).

  13. The influence of typical ways of operating and air-handling unit on the sensory pollution load from used bag filters

    DEFF Research Database (Denmark)

    Mysen, M.; Clausen, Geo; Bekö, Gabriel

    2003-01-01

    An experiment was performed to determine whether the sensory pollution emitted from a bag filter that had been used for 3 months in a suburban area in Denmark was influenced by different ways of operating the air-handling unit (AHU). Samples of the used filter were pre-conditioned to simulate thr...... the airflow outside working hours would significantly increase the sensory pollution emitted by a used bag filter immediately after the AHU is turned on, in comparison with continuous airflow through the AHU (P...... operating conditions: 1) switched off overnight; 2) airflow reduced to 10% overnight; and 3) continuous 100% operation. Outside air passed through the samples and the acceptability of the air after the filter was assessed by a panel of subjects. The results indicate that turning off the AHU or reducing...

  14. Development of filters for exhaust air or off-gas cleaning

    International Nuclear Information System (INIS)

    Wilhelm, J.

    1988-01-01

    The activities of the 'Laboratorium fuer Aerosolphysik und Filtertechnik II' of the 'Kernforschungszentrum Karlsruhe' concentrate on the development of filters to be used for cleaning nuclear and conventional exhaust air and off-gas. Originally, these techniques were intended to be applied in nuclear facilities only. Their application for conventional gas purification, however, has led to a reorientation of research and development projects. By way of example, it is reported about the use of the multi-way sorption filter for radioiodine removal in nuclear power plants and following flue-gas purification in heating power plants as well as for off-gas cleaning in chemical industry. The improvement of HEPA filters and the development of metal fibre filters has led to components which can be used in the range of high humidity and moisture as well as at high temperatures and an increased differential pressure. The experience obtained in the field of high-efficiency filtering of nuclear airborne particles is made use of during the investigations concerning the removal of particles of conventional pollutants in the submicron range. A technique of radioiodine removal and an improved removal of airborne particles has been developed for use in the future reprocessing plant. Thus, a maximum removal efficiency can be achieved and an optimum waste management is made possible. It is reported about the components obtained as a result of these activities and their use for off-gas cleaning in the Wackersdorf reprocessing plant (WAW). (orig.) [de

  15. Corrosive environment tester for filter media

    International Nuclear Information System (INIS)

    Petit, G.S.; Weber, C.W.; Keinberger, C.A.; Rivers, R.D.

    1977-02-01

    Two continuous dynamic systems have been designed and fabricated for testing filter media in humid, corrosive environments--one for fluorine or fluoride exposures, and the other for nitrogen dioxide exposures. The tester using fluorine or fluoride atmospheres was constructed of nickel and the one using nitrogen dioxide was fabricated of stainless steel. Other corrosive gases could be used with the appropriate choice of system. For example, chlorine or hydrogen chloride could be used in the system fabricated of nickel, and sulfur dioxides or ammonia could be used in the stainless steel testing apparatus. Each tester is comprised of four equivalent dynamic systems designed for diluting a corrosive reagent with dry air, then with humidified air to provide a humid-corrosive environment for filter media testing. Auxiliary equipment includes a water injection system, corrosive reagent supply systems, and an automatic pressure differential (ΔP) monitoring and recording system. The testers are relatively maintenance-free and have operated continuously for periods as long as 96 h without requiring any attention, during total exposures of materials exceeding 600 h

  16. Plutonium Finishing Plant (PFP) Waste Composition and High Efficiency Particulate Air Filter Loading

    Energy Technology Data Exchange (ETDEWEB)

    ZIMMERMAN, B.D.

    2000-12-11

    This analysis evaluates the effect of the Plutonium Finishing Plant (PFP) waste isotopic composition on Tank Farms Final Safety Analysis Report (FSAR) accidents involving high-efficiency particulate air (HEPA) filter failure in Double-Contained Receiver Tanks (DCRTs). The HEPA Filter Failure--Exposure to High Temperature or Pressure, and Steam Intrusion From Interfacing Systems accidents are considered. The analysis concludes that dose consequences based on the PFP waste isotopic composition are bounded by previous FSAR analyses. This supports USQD TF-00-0768.

  17. Radionuclide release from non-nuclear energy production: a sensitive technique for measuring lead-210 on air filters

    International Nuclear Information System (INIS)

    Coles, D.G.; Meadows, J.W.T.

    1978-01-01

    A method of measuring 210 Pb content on air filters directly by Ge(Li) gamma-ray spectroscopy and thus eliminating costly and lengthy radiochemical procedures is discussed. Successful analyses of filters with typical atmospheric concentrations (0.3 to 30 fCi/m 3 ) of 210 Pb have been done with air volumes as low as 5000 m 3 with a low-background, high-resolution, high-efficiency spectrometer. Examples are presented which demonstrate the usefulness of the technique for inexpensive 210 Pb analyses in normal environmental air-sampling operations. Studies of the movements, effects, and chemistries of emissions from coal-fired power plants and geothermal areas are in progress

  18. Experimental Study on Ultrafine Particle Removal Performance of Portable Air Cleaners with Different Filters in an Office Room

    Directory of Open Access Journals (Sweden)

    Huan Ma

    2016-01-01

    Full Text Available Size- and time-dependent aerodynamic behaviors of indoor particles, including PM1.0, were evaluated in a school office in order to test the performance of air-cleaning devices using different filters. In-situ real-time measurements were taken using an optical particle counter. The filtration characteristics of filter media, including single-pass efficiency, volume and effectiveness, were evaluated and analyzed. The electret filter (EE medium shows better initial removal efficiency than the high efficiency (HE medium in the 0.3–3.5 μm particle size range, while under the same face velocity, the filtration resistance of the HE medium is several times higher than that of the EE medium. During service life testing, the efficiency of the EE medium decreased to 60% with a total purifying air flow of 25 × 104 m3/m2. The resistance curve rose slightly before the efficiency reached the bottom, and then increased almost exponentially. The single-pass efficiency of portable air cleaner (PAC with the pre-filter (PR or the active carbon granule filter (CF was relatively poor. While PAC with the pre-filter and the high efficiency filter (PR&HE showed maximum single-pass efficiency for PM1.0 (88.6%, PAC with the HE was the most effective at removing PM1.0. The enhancement of PR with HE and electret filters augmented the single-pass efficiency, but lessened the airflow rate and effectiveness. Combined with PR, the decay constant of large-sized particles could be greater than for PACs without PR. Without regard to the lifetime, the electret filters performed better with respect to resource saving and purification improvement. A most penetrating particle size range (MPPS: 0.4–0.65 μm exists in both HE and electret filters; the MPPS tends to become larger after HE and electret filters are combined with PR. These results serve to provide a better understanding of the indoor particle removal performance of PACs when combined with different kinds of filters in

  19. Hybrid Filter Membrane

    Science.gov (United States)

    Laicer, Castro; Rasimick, Brian; Green, Zachary

    2012-01-01

    Cabin environmental control is an important issue for a successful Moon mission. Due to the unique environment of the Moon, lunar dust control is one of the main problems that significantly diminishes the air quality inside spacecraft cabins. Therefore, this innovation was motivated by NASA s need to minimize the negative health impact that air-suspended lunar dust particles have on astronauts in spacecraft cabins. It is based on fabrication of a hybrid filter comprising nanofiber nonwoven layers coated on porous polymer membranes with uniform cylindrical pores. This design results in a high-efficiency gas particulate filter with low pressure drop and the ability to be easily regenerated to restore filtration performance. A hybrid filter was developed consisting of a porous membrane with uniform, micron-sized, cylindrical pore channels coated with a thin nanofiber layer. Compared to conventional filter media such as a high-efficiency particulate air (HEPA) filter, this filter is designed to provide high particle efficiency, low pressure drop, and the ability to be regenerated. These membranes have well-defined micron-sized pores and can be used independently as air filters with discreet particle size cut-off, or coated with nanofiber layers for filtration of ultrafine nanoscale particles. The filter consists of a thin design intended to facilitate filter regeneration by localized air pulsing. The two main features of this invention are the concept of combining a micro-engineered straight-pore membrane with nanofibers. The micro-engineered straight pore membrane can be prepared with extremely high precision. Because the resulting membrane pores are straight and not tortuous like those found in conventional filters, the pressure drop across the filter is significantly reduced. The nanofiber layer is applied as a very thin coating to enhance filtration efficiency for fine nanoscale particles. Additionally, the thin nanofiber coating is designed to promote capture of

  20. Development of a small air-cooled ``midnight sun'' thermophotovoltaic electric generator

    Science.gov (United States)

    Fraas, Lewis M.; Xiang, Huang Han; Hui, She; Ferguson, Luke; Samaras, John; Ballantyne, Russ; Seal, Michael; West, Ed

    1996-02-01

    A natural gas fired thermophotovoltaic generator using infrared-sensitive GaSb cells and a silicon carbide emitter is described. The emitter is designed to operate at 1400 °C. Twelve GaSb receivers surround the emitter. Each receiver contains a string of series connected cells. Special infrared filters are bonded to each cell. These filters transmit short wavelength useful IR to the cells while reflecting longer wavelength IR back to the emitter. Combustion air is supplied to the burner through a counterflow heat exchanger where the air is preheated by the exhaust from the burner. The unit is air cooled and designed to produce approximately 100 Watts of electric power.

  1. New air cleaning technology in Japan

    International Nuclear Information System (INIS)

    Yoshida, Y.; Kitani, S.; Matsui, H.; Ikezawa, Y.

    1981-01-01

    Application of the new techniques and improvements in air cleaning systems have been made to reduce release of radioactive materials from nuclear facilities based on the ALARA concept. For example, the reduction of release of radioactive gaseous effluents has been made by installation of a charcoal gas hold-up system and a clean steam supply system for a turbine gland seal in a BWR and of a gas decay tank system in a PWR. In connection with the effort for reduction of releases in plants, research and development on air cleaning technology have also been made. Some activities mentioned in the present paper are: removal of particulates, airborne radioiodine, noble gases and tritium; penetration characteristics of submicron DOP aerosol for HEPA filters; radioiodine removal from air exhausts; and operational performance of the incineration plants using ceramic filters

  2. Radioactivity in the furnace air-cleaning filter from a house with an unusually high level of airborne radon

    International Nuclear Information System (INIS)

    Rundo, J.; Essling, M.A.; Urnezis, P.W.

    1979-01-01

    The amounts of the three short-lived daughters of radon on the furnace air-cleaning filter from a house with a high level of radon were estimated to be 8.2, 33, and 38 kBq (0.22, 0.89, and 1.03 μCi) for 218 Po, 214 Pb, and 214 Bi, respectively, at the time of removal from the furnace. These data were used to calculate the airborne concentrations of the three, and the results indicated that about 70% of the daughters were lost to surfaces in the house and by impaction in the air ducts. The filter's content of 210 Pb was found to be 4.4 kBg (0.12 μCi); from this the average concentration of radon-producing filterable daughters during the time the furnace blower operated, was estimated to be 860 Bq m -3 . This indicated that there was no significant loss to surfaces or in air ducts. Possible reasons for the difference are given. The filter was also found to contain 1 kBq (27 nCi) of 212 Bi from the thorium series

  3. Improved airline-type supplied-air plastic suit

    International Nuclear Information System (INIS)

    Jolley, L. Jr.; Zippler, D.B.; Cofer, C.H.; Harper, J.A.

    1978-06-01

    Two piece supplied-air plastic suits are used extensively at the Savannah River Plant for personnel protection against inhalation of airborne plutonium and tritium. Worker comfort and noise level problems gave impetus to development of an improved suit and aid distribution system. The resulting plastic suit and development work are discussed. The plastic suit unit cost is less than $20, the hearing zone noise level is less than 75 dBA, protection factors exceed 10,000, and user comfort is approved. This suit is expected to meet performance requirements for unrestricted use

  4. Filterability of freshly-collected sickle erythrocytes under venous oxygen pressure without exposure to air.

    Science.gov (United States)

    Shah, Siddharth; Acholonu, Rhonda Graves; Ohene-Frempong, Kwaku; Asakura, Toshio

    2015-12-01

    We previously found that blood samples collected from steady-state patients with sickle cell disease (SCD) without exposure to air contain a new type of reversibly sickled cells (RSCs) with blunt edges at a level of as high as 78%. Since partial oxygenation of once-deoxygenated sickled cells with pointy edges to near venous oxygen pressure generates similar sickled cells with blunt edges in vitro, we named them as partially oxygenated sickled cells (POSCs). On the other hand, partial deoxygenation of once-oxygenated SS cells to venous oxygen pressure generates partially deoxygenated sickled cells (PDSCs) with pointy edges. In this study, we obtained blood samples from 6 steady-state patients with SCD under venous oxygen pressure without exposure to air, subjected them to various oxygenation/deoxygenation/reoxygenation cycles, and studied their filterability through a membrane filter with pore diameter of 3μm, the theoretical minimum diameter of a capillary. Our results indicated that discocytes, POSCs with blunt edges, and irreversibly sickled cells could deform and pass through the filter, while PDSCs with pointy edges were rigid and could not. The filterability of SS cells seems to be related to the length and amount of deoxy-hemoglobin S fibers in the cells. Copyright © 2015. Published by Elsevier Inc.

  5. Operational readiness of filtered air discharge monitoring systems

    International Nuclear Information System (INIS)

    Lafortune, J.F.; Jamieson, T.J.

    1993-08-01

    An assessment of the operational readiness of the Filtered Air Discharge (FAD) Stack Monitoring systems, installed in Canadian CANDU nuclear power plants, was performed in this project. Relevant Canadian and foreign standards and regulatory requirements have been reviewed and documentation on FAD stack monitoring system design, operation, testing and maintenance have been assessed to identify likely causes and potential failures of FAD stack monitoring systems and their components under both standby and accident conditions. Recommendations have also been provided in this report for design and performance review guidelines for CANDU stations. A case study of the FAD stack monitoring system at Pickering NGS is also documented in this report

  6. Low-temperature baseboard heaters with integrated air supply - An analytical and numerical investigation

    Energy Technology Data Exchange (ETDEWEB)

    Ploskic, Adnan; Holmberg, Sture [Fluid and Climate Technology, School of Architecture and Built Environment, KTH, Marinens vaeg 30, SE-13640 Handen, Stockholm (Sweden)

    2011-01-15

    The functioning of a hydronic baseboard heating system with integrated air supply was analyzed. The aim was to investigate thermal performance of the system when cold outdoor (ventilation) airflow was forced through the baseboard heater. The performance of the system was evaluated for different ventilation rates at typical outdoor temperatures during the Swedish winter season. Three different analytical models and Computational Fluid Dynamics (CFD) were used to predict the temperature rise of the airflow inside the baseboard heater. Good agreement between numerical (CFD) and analytical calculations was obtained. Calculations showed that it was fully possible to pre-heat the incoming airflow to the indoor temperature and to cover transmission losses, using 45 C supply water flow. The analytical calculations also showed that the airflow per supply opening in the baseboard heater needed to be limited to 7.0 l/s due to pressure losses inside the channel. At this ventilation rate, the integrated system with one air supply gave about 2.1 more heat output than a conventional baseboard heating system. CFD simulations also showed that the integrated system was capable of countering downdraught created by 2.0 m high glazed areas and a cold outdoor environment. Draught discomfort in the case with the conventional system was slightly above the recommended upper limit, but heat distribution across whole analyzed office space was uniform for both heating systems. It was concluded that low-temperature baseboard heating systems with integrated air supply can meet both international comfort requirements, and lead to energy savings in cold climates. (author)

  7. 500 Watt Diesel Fueled TPV Portable Power Supply

    Science.gov (United States)

    Horne, W. E.; Morgan, M. D.; Sundaram, V. S.; Butcher, T.

    2003-01-01

    A test-bed 500 watt diesel fueled thermophotovoltaic (TPV) portable power supply is described. The goal of the design is a compact, rugged field portable unit weighing less than 15 pounds without fuel. The conversion efficiency goal is set at 15% fuel energy to electric energy delivered to an external load at 24 volts. A burner/recuperator system has been developed to meet the objectives of high combustion air preheat temperatures with a compact heat exchanger, low excess air operation, and high convective heat transfer rates to the silicon carbide emitter surface. The burner incorporates a air blast atomizer with 100% of the combustion air passing through the nozzle. Designed firing rate of 2900 watts at 0.07 gallons of oil per hour. This incorporates a single air supply dc motor/fan set and avoids the need for a system air compressor. The recuperator consists of three annular, concentric laminar flow passages. Heat from the combustion of the diesel fuel is both radiantly and convectively coupled to the inside wall of a cylindrical silicon carbide emitter. The outer wall of the emitter then radiates blackbody energy at the design temperature of 1400°C. The cylindrical emitter is enclosed in a quartz envelope that separates it from the photovoltaic (PV) cells. Spectral control is accomplished by a resonant mesh IR band-pass filter placed between the emitter and the PV array. The narrow band of energy transmitted by the filter is intercepted and converted to electricity by an array of GaSb PV cells. The array consists of 216 1-cm × 1-cm GaSb cells arranged into series and parallel arrays. An array of heat pipes couple the PV cell arrays to a heat exchanger which is cooled by forced air convection. A brief status of the key TPV technologies is presented followed by data characterizing the performance of the 500 watt TPV system.

  8. Effect of supply air temperature on air distribution in a room with radiant heating and mechanical ventilation

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Zhao, Jianing; Fang, Lei

    2017-01-01

    and the horizontal distribution of containment concentration in the breathing zone were measured as the supply air temperature ranged from 15.0°C (59°F)to 19.0°C (66.2°F). The results showed that the vertical air temperature differences were less than 0.3°C (32.5°F) with FH+MV or CH+MV and between 1.9°C (35.4°F...

  9. Extended-life nuclear air cleaning filters via dynamic exclusion prefilters

    Energy Technology Data Exchange (ETDEWEB)

    Wright, S.R.; Crouch, H.S.; Bond, J.H. [Micro Composite Materials Corp., Durham, NC (United States)

    1997-08-01

    The primary objective of this investigation was to ascertain if a dynamic, self-cleaning particulate exclusion precleaner, designed for relatively large dust removal (2 to 100+ {mu}m diameter particles) from helicopter turbine inlets, could be extended to submicron filtration. The improved device could be used as a prefilter for HEPA filtration systems, significantly increasing service life. In nuclear air cleaning, its use would reduce the amount of nuclear particulate matter that would otherwise be entrapped in the HEPA filter cartridge/panel, causing fouling and increased back pressure, as well as requiring subsequent disposal of the contaminated media at considerable expense. A unique (patent-pending) mechanical separation device has recently been developed to extract particulate matter from fluid process streams based on a proprietary concept called Boundary Layer Momentum Transfer (BLMT). The device creates multiple boundary layers that actively exclude particles from entering the perimeter of the device, while allowing air to traverse the boundaries relatively unimpeded. A modified two-dimensional (2-D) computerized flow simulation model was used to assist in the prototype design. Empirical results are presented from particle breakthrough and AP experiments obtained from a reduced-scale prototype filter. Particles larger than 0.23 {mu}m were actively excluded by the prototype, but at a higher pressure drop than anticipated. Experimental data collected indicates that the filter housing and the inlet flow configuration may contribute significantly to improvements in device particle separation capabilities. Furthermore, preliminary experiments have shown that other downstream pressure drop considerations (besides those just across the spinning filtration disks) must be included to accurately portray the AP across the device. Further detailed quantitative investigations on a larger scale (1,000 CFM) prototype are warranted. 3 refs., 5 figs., 2 tabs.

  10. Use of perforated acoustic panels as supply air diffusers in diffuse ceiling ventilation systems

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Kazemi, Seyed Hossein; Ardkapan, Siamak Rahimi

    Ventilation is needed for diluting and removing the contaminants, odour and excess heat from the building interior. It is important that the inhabitants perceive the ventilated spaces as comfortable. Therefore, the supply air should reach all parts of the occupied zones. Troldtekt has been...... manufacturing perforated acoustic panels for the last 13 years. The panels can be used not only in applications related to acoustics but also as low pressure drop supply air diffusers, particularly in diffuse ceiling ventilation systems. The present study verifies on a theoretically level the performance...

  11. Report on the IAEA-CU-2006-11 proficiency test on the determination of gamma emitting radionuclides in air filters

    International Nuclear Information System (INIS)

    Shakhashiro, A.; Kim, C.-K.; Sansone, U.; Ferrari, M.; Sill, D.

    2006-10-01

    This report summarises the results of the IAEA-CU-2006-11 proficiency test on the determination of gamma emitting radionuclides in air filters, organised within the frame of the IAEA Technical Cooperation project RER/8/009 ''Air Pollution Monitoring in the Mediterranean Region''. The proficiency test was conducted by the Reference Materials Group of the Chemistry Unit (Physics, Chemistry and Instrumentation Laboratory) of the IAEA's analytical laboratories located in Seibersdorf (Austria) in cooperation with the Radiological and Environmental Sciences Laboratory, Department of Energy in the United States of America. The objective of TC project RER/8/009 is to contribute to air quality improvement through the establishment of a network for air monitoring and the design of a remedial strategy where the monitoring shows poor air quality. A spiked air filter with known activities of gamma emitting radionuclides prepared by the Department of Energy of the United States of America was used in this proficiency test. 14 spiked filters were distributed to the participating laboratories in April 2006. The deadline for receiving the results from the participants was set at 31 July 2006. The participating laboratories were requested to analyse the samples employing the methods used in their routine work, so that their performance on the test samples could be directly related to the real performance of the laboratory. Each laboratory was given a confidential code to assure the anonymity of the evaluation results. From the 14 initially registered, 11 laboratories reported their results back to the IAEA. The analytical results of the participating laboratories were evaluated against the reference values assigned to the reference air filter, and a rating system was applied

  12. Removal of Particles from the Supply Air of Ventilation Systems Avoiding the Formation of Sensory Pollution Source

    DEFF Research Database (Denmark)

    Bekö, Gabriel

    2008-01-01

    of filter banks, including filter replacement in due time, is also important. The aim of this work was to gain more knowledge leading to a better understanding and solving a long recognized indoor environmental problem. The thesis deals with three core areas. Firstly, experiments were conducted to obtain...... ventilation filters. Used and new filters were found to initially remove large amounts of ozone from the air that passed through. The initial ozone removal efficiency (~50%) decreased within an hour to a low and constant value (...

  13. Viral Penetration of High Efficiency Particulate Air (HEPA) Filters (PREPRINT)

    Science.gov (United States)

    2009-09-01

    US Plastics, Lima , 155 Ohio). Each path runs through a test article and thence through one AGI-30 all-glass 156 impinger (Chemglass, Vineland, N.J...rotameter (Blue–White 400, Huntington Beach , California, or PMR1-159 101346, Cole–Parmer, Vernon Hills, Illinois). At the end of the sampling path...fibrous Filters." J. Air Pollution Control Assoc. 30 [4]: 501 377–381. 502 Leenders, G.J.M, A.C. Bolle, and J. Stadhouders. 1984. “A Study of the

  14. Performance and Effectiveness of Portable Air Cleaners in an Office Room

    DEFF Research Database (Denmark)

    Ardkapan, Siamak Rahimi; Afshari, Alireza; Bergsøe, Niels Christian

    2015-01-01

    Nowadays, many people work in an office environment. Air pollutants, including particles and gases, are generated by humans and by different devices that are used in offices. Pollutants can also enter an office room with the air supplied from outdoors. It has been established that air pollutants...... and particles in an office room. The particle removal effectiveness of the technologies was also determined in order to clarify their ability to remove UFPs (ultrafine particles) in the office room. The tested five air cleaning technologies are non-thermal plasma, corona discharge ionizer, portable air purifier......, electrostatic fibrous filter and three-dimensional fibrous filter. The interior surfaces of the office room emit low levels of volatile organic compounds, since the office room has not been refurbished for about two decades. The results showed that the particle removal effectiveness of the technologies...

  15. Study on the influence of supplying compressed air channels and evicting channels on pneumatical oscillation systems for vibromooshing

    Science.gov (United States)

    Glăvan, D. O.; Radu, I.; Babanatsas, T.; Babanatis Merce, R. M.; Kiss, I.; Gaspar, M. C.

    2018-01-01

    The paper presents a pneumatic system with two oscillating masses. The system is composed of a cylinder (framework) with mass m1, which has a piston with mass m2 inside. The cylinder (framework system) has one supplying channel for compressed air and one evicting channel for each work chamber (left and right of the piston). Functionality of the piston position comparatively with the cylinder (framework) is possible through the supplying or evicting of compressed air. The variable force that keeps the movement depends on variation of the pressure that is changing depending on the piston position according to the cylinder (framework) and to the section form that is supplying and evicting channels with compressed air. The paper presents the physical model/pattern, the mathematical model/pattern (differential equations) and numerical solution of the differential equations in hypothesis with the section form of supplying and evicting channels with compressed air is rectangular (variation linear) or circular (variation nonlinear).

  16. Development of glass-fiber high-efficiency particulate air filters of high structural strength on the basis of the establishment of failure mechanisms

    International Nuclear Information System (INIS)

    Ruedinger, V.; Ricketts, C.I.; Wilhelm, J.G.; Alken, W.

    1987-01-01

    Practical experience from routine operation in nuclear installations as well as extensive bench and laboratory testing proved the structural limits of HEPA filters to be very low thus demonstrating the need for improvement of their structural strength. Detailed analysis of the courses and modes of filter failure under the challenge of dry air at high velocities and ambient temperature, together with additional measurements, allowed the establishment of the dominating mechanisms of filter failure. Based on this information, the following three options for effective and economical improvements in filter structural limits exist: (1) an increase in the tensile strength of the filter medium; (2) an increase in the stability of the pack to prevent the swelling of individual pleats; and (3) an increase in the area moment of inertia of the separators and a decrease in the sharpness of their edges. By using a reinforced glass fiber filter medium, the structural strength of standard size HEPA filters was increased to 31 kPa with dry air and beyond 10 kPa with air at high humidity. Prototype filters built with standard glass-fiber media and separators with inclined corrugations exhibited failure pressures of approximately 50 kPa under high velocity airflows. The combination of both types of improvements, together with other measures, will soon lead to even higher HEPA-filter structural strength

  17. An Investigation on the Efficiency of Air Purification Using a Biofilter with Activated Bed of Different Origin

    Directory of Open Access Journals (Sweden)

    Zagorskis Alvydas

    2014-12-01

    Full Text Available Recent studies in the area of biological air treatment in filters have addressed fundamental key issues, such as a biofilter bed of different origin composed of natural zeolite granules, foam cubes and wood chips. When foam and zeolite are mixed with wood chips to remove volatile organic compounds from the air, not only biological but also adsorption air purification methods are accomplished. The use of complex purification technologies helps to improve the efficiency of a filter as well as the bed service life of the filter bed. Investigations revealed that microorganisms prevailing in biological purification, can also reproduce themselves in biofilter beds of inorganic and synthetic origin composed of natural zeolite and foam. By cultivating associations of spontaneous microorganisms in the filter bed the dependencies of the purification efficiency of filter on the origin, concentration and filtration time of injected pollutants were determined. The highest purification efficiency was obtained when air polluted with acetone vapour was supplied to the equipment at 0.1 m/s of superficial gas velocity. When cleaning air from volatile organic compounds (acetone, toluene and butanol, under the initial pollutant concentration of ~100 mg/m3, the filter efficiency reached 95 %.

  18. Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions

    Science.gov (United States)

    Giffin, Paxton K.; Parsons, Michael S.; Unz, Ronald J.; Waggoner, Charles A.

    2012-05-01

    The Institute for Clean Energy Technology (ICET) at Mississippi State University has developed a test stand capable of lifecycle testing of high efficiency particulate air filters and other filters specified in American Society of Mechanical Engineers Code on Nuclear Air and Gas Treatment (AG-1) filters. The test stand is currently equipped to test AG-1 Section FK radial flow filters, and expansion is currently underway to increase testing capabilities for other types of AG-1 filters. The test stand is capable of producing differential pressures of 12.45 kPa (50 in. w.c.) at volumetric air flow rates up to 113.3 m3/min (4000 CFM). Testing is performed at elevated and ambient conditions for temperature and relative humidity. Current testing utilizes three challenge aerosols: carbon black, alumina, and Arizona road dust (A1-Ultrafine). Each aerosol has a different mass median diameter to test loading over a wide range of particles sizes. The test stand is designed to monitor and maintain relative humidity and temperature to required specifications. Instrumentation is implemented on the upstream and downstream sections of the test stand as well as on the filter housing itself. Representative data are presented herein illustrating the test stand's capabilities. Digital images of the filter pack collected during and after testing is displayed after the representative data are discussed. In conclusion, the ICET test stand with AG-1 filter testing capabilities has been developed and hurdles such as test parameter stability and design flexibility overcome.

  19. Characterization of Airborne Particles Collected from Car Engine Air Filters Using SEM and EDX Techniques

    Science.gov (United States)

    Heredia Rivera, Birmania; Gerardo Rodriguez, Martín

    2016-01-01

    Particulate matter accumulated on car engine air-filters (CAFs) was examined in order to investigate the potential use of these devices as efficient samplers for collecting street level air that people are exposed to. The morphology, microstructure, and chemical composition of a variety of particles were studied using scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX). The particulate matter accumulated by the CAFs was studied in two categories; the first was of removed particles by friction, and the second consisted of particles retained on the filters. Larger particles with a diameter of 74–10 µm were observed in the first category. In the second one, the detected particles had a diameter between 16 and 0.7 µm. These particles exhibited different morphologies and composition, indicating mostly a soil origin. The elemental composition revealed the presence of three groups: mineral (clay and asphalt), metallic (mainly Fe), and biological particles (vegetal and animal debris). The palynological analysis showed the presence of pollen grains associated with urban plants. These results suggest that CAFs capture a mixture of atmospheric particles, which can be analyzed in order to monitor urban air. Thus, the continuous availability of large numbers of filters and the retroactivity associated to the car routes suggest that these CAFs are very useful for studying the high traffic zones within a city. PMID:27706087

  20. Characterization of Airborne Particles Collected from Car Engine Air Filters Using SEM and EDX Techniques

    Directory of Open Access Journals (Sweden)

    Birmania Heredia Rivera

    2016-10-01

    Full Text Available Particulate matter accumulated on car engine air-filters (CAFs was examined in order to investigate the potential use of these devices as efficient samplers for collecting street level air that people are exposed to. The morphology, microstructure, and chemical composition of a variety of particles were studied using scanning electron microscopy (SEM and energy-dispersive X-ray (EDX. The particulate matter accumulated by the CAFs was studied in two categories; the first was of removed particles by friction, and the second consisted of particles retained on the filters. Larger particles with a diameter of 74–10 µm were observed in the first category. In the second one, the detected particles had a diameter between 16 and 0.7 µm. These particles exhibited different morphologies and composition, indicating mostly a soil origin. The elemental composition revealed the presence of three groups: mineral (clay and asphalt, metallic (mainly Fe, and biological particles (vegetal and animal debris. The palynological analysis showed the presence of pollen grains associated with urban plants. These results suggest that CAFs capture a mixture of atmospheric particles, which can be analyzed in order to monitor urban air. Thus, the continuous availability of large numbers of filters and the retroactivity associated to the car routes suggest that these CAFs are very useful for studying the high traffic zones within a city.

  1. The active filter voltage ripple correction system of the Brookhaven AGS main magnet power supply

    International Nuclear Information System (INIS)

    Marneris, I.; Bonati, R.; Geller, J.; Sandberg, J.N.; Soukas, A.

    1995-01-01

    This paper, and a companion paper, describe the improvements to the Main Magnet Power Supply (MMPS) so that it enables a more flexible operation of the AGS, enhances its reliability, and also improves the MMPS's ultimate performance specifications. One of the major areas for the latter is the fixed target program operating off the AGS slow extracted beam lines. The active filter, by improving the MMPS output ripple, is instrumental in the improvement of the ultimate duty factor of the extraction beam spill

  2. The impact of mass flow and masking on the pressure drop of air filter in heavy-duty diesel engine

    Directory of Open Access Journals (Sweden)

    Gorji-Bandpy Mofid

    2012-04-01

    Full Text Available This paper presents a computational fluid dynamics (CFD calculation approach to predict and evaluate the impact of the mass-flow inlet on the pressure drop of turbocharger`s air filtfer in heavy-duty diesel engine. The numerical computations were carried out using a commercial CFD program whereas the inlet area of the air filter consisted of several holes connected to a channel. After entering through the channel, the air passes among the holes and enters the air filter. The effect of masking holes and hydraulic diameter is studied and investigated on pressure drop. The results indicate that pressure drop increase with decreasing of hydraulic diameter and masking of the holes has considerable affect on the pressure drop.

  3. Operating experience of a portable thermophotovoltaic power supply

    Science.gov (United States)

    Becker, Frederick E.; Doyle, Edward F.; Shukla, Kailash

    1999-03-01

    Two configurations of man-portable thermophotovoltaic (TPV) power supplies based on Thermo Power's supported continuous fiber emitter have been designed, built, and are being tested. The systems use narrow-band, fibrous, ytterbia emitters radiating to bandgap matched silicon photovoltaic arrays with dielectric stack filters for optical energy recovery and recuperators for thermal energy recovery. The systems have been designed for operation with propane and with combustion air preheat temperatures of up to 1250 K. To operate at air preheat temperatures above the auto-ignition temperature of the fuel, a unique fuel delivery system was devised which results in the micromixing and rapid combustion of the fuel and air right in the emitter fibers. This allows the ytterbia emitter fibers to run much hotter (˜2000 K) than any of the surrounding structure.

  4. Device for filtering gaseous media

    International Nuclear Information System (INIS)

    Benzel, M.

    1978-01-01

    The air filter system for gaseous radioactive substances consists of a vertical chamber with filter material (charcoal, e.g. impregnated). On one side of the chamber there is an inlet compartment and an outlet compartment. On the other side a guiding compartment turns the gas flow coming from the natural-air side through the lower part of filter chamber to the upper part of the filter. The gas flow leaves the upper part through the outlet conpartment as cleaned-air flow. The filter material may be filled into the chamber from above and drawn off below. For better utilization of the filter material the filter chamber is separated by means of a wall between the inlet and outlet compartment. This partition wall consist of two sheets arranged one above the other provided with slots which may be superposed in alignment. In this case filter material is tickling from the upper part of the chamber into the lower part avoiding to form a crater in the filter bed. (DG) [de

  5. The Calculation of Self-Disposal Date by Analyzing the Radioactive Contamination of Air Filters Disused in Radioisotope Production Facility

    International Nuclear Information System (INIS)

    Kim, Sung Ho; Lee, Bu Hyung; Kwon, Soo Il

    2016-01-01

    The aim of the study is to decrease the diffusion of air contamination which occurred in radiation work places handle radioisotope under the permissible level. Accordingly, we replaced used air filter with a new one at the appropriate time , and computed disposal dates for disposing used air filters by calculate radioactive contamination. Air filter contaminated by radioactivity is possible to be self-disposed on condition that all detected nuclides is below permissible level according to Nuclear Safety and Security Commission (NSSC) notification No. 2014-003. Radioisotope, produced by 30, 50 MeV cyclotron and carried from other institutions, is used to treat patients, diagnose diseases, and research technology in Korea Institute of Radiological and Medical Sciences (KIRAMS). With unsealed sources generate radioactive contamination in air, it is important to use fume hood or hot cell. The accurate date needs to be calculated by the equation for calculation of self disposal date. If disposal date is in 1000 days, disposal for external institution is required. With increasing the number of medical institute which was related to use the radioisotopes, the importance of radioactive safety management was increased. As disposing radioactive waste, in particular, is the procedure of inspecting for releasing radioactive waste to outside, appropriate action and continuous research are required at a radioactive safety management.

  6. The investigation on compressed air quality analysis results of nuclear power plants

    International Nuclear Information System (INIS)

    Sung, K. B.; Kim, H. K.; Kim, W. S.

    2000-01-01

    The compressed air system of nuclear power plants provides pneumatic power for both operation and control of various plant equipment, tools, and instrumentation. Included in the air supply systems are the compressors, coolers, moisture separators, dryers, filters and air receiver tanks that make up the major items of equipment. The service air system provides oil-free compressed air for general plant and maintenance use and the instrument air system provides dry, oil-free, compressed air for both nonessential and essential components and instruments. NRC recommended the periodic checks on GL88-14 'Instrument air supply system problems affecting safety-related equipment'. To ensure that the quality of the instrument air is equivalent to or exceeds the requirement s of ISA-S7.3(1975), air samples are taken at every refueling outage and analyzed for moisture, oil and particulate content. The over all results are satisfied the requirements of ISA-S7.3

  7. Effectiveness evaluation of sources of supply and systems filter in production process of breathing air

    Directory of Open Access Journals (Sweden)

    Woźniak Arkadiusz

    2015-12-01

    Full Text Available The determination of how efficiently filtration systems used for the production of breathing air used in hyperbaric environments are operating is significant both from theoretical and practical points of view. The quality of breathing air and the breathing mixes based on air is crucial with regard to divers' safety. Paradoxically, a change in regulations regarding quality requirements for breathing mixes has imposed the necessity to verify both the technical equipment and laboratory procedures used in their production and verification. The following material, which is a continuation of previous publications, presents results of the conducted research along with the evaluation of effectiveness of the filtration systems used by the Polish Navy.

  8. Filters in nuclear facilities

    International Nuclear Information System (INIS)

    Berg, K.H.; Wilhelm, J.G.

    1985-01-01

    The topics of the nine papers given include the behavior of HEPA filters during exposure to air flows of high humidity as well as of high differential pressure, the development of steel-fiber filters suitable for extreme operating conditions, and the occurrence of various radioactive iodine species in the exhaust air from boiling water reactors. In an introductory presentation the German view of the performance requirements to be met by filters in nuclear facilities as well as the present status of filter quality assurance are discussed. (orig.) [de

  9. Trace element analysis of old exposed air filters: a feasibility study

    International Nuclear Information System (INIS)

    Pattenden, N.J.; Fisher, E.M.R.; Bones, E.M.

    1979-10-01

    A limited number of old exposed air filters from a network of sampling stations extending the length of North and South America have been analysed for many trace elements. (The network is run by the United States Department of Energy Environmental Measurements Laboratory). The objective was to assess the possible value of a large program of such measurements for providing information on the trace element concentrations in airborne particulates existing at the time of sample collection. On the basis of the evidence obtained, it is considered that valid information could be extracted in this way. In view of the extent of the store of old filters, which cover about a 10 year period up to the present day from stations spread over the North and South American continents and elsewhere, such a program appears to be well worthwhile. (author)

  10. Investigating the impact of noise incidence angle on the sound insulation of a supply air window

    DEFF Research Database (Denmark)

    Hansen, Morten B.; Tambo, Torben

    2015-01-01

    for the highest frequencies are less than the sound insulation of the same window measured in the laboratory. The aim of this paper is through simulations in the geometric acoustic simulation software ODEON, to investigate the impact of noise incidence angle on the sound insulation of the Supply Air Window......The Danish Environmental Agency introduced in 2007 a guideline “Noise from roads”, in which noise limits for open windows were introduced. This guideline has led to investigations of open windows with good sound insulation, and among one of these windows are the “Supply Air Window”. Prior sound...... insulation measurements of the Supply Air Window show a difference in the frequency range above 2 kHz, for field measurements carried out according to EN ISO 140-5 and laboratory measurements carried out according to EN ISO 10140-2. It is found that the sound insulation measured in the field setup...

  11. Extraction of semivolatile organic compounds from high-efficiency particulate air (HEPA) filters by supercritical carbon dioxide

    International Nuclear Information System (INIS)

    Schilling, J.B.

    1997-09-01

    Supercritical fluid extraction (SFE) using unmodified carbon dioxide has been explored as an alternative method for the extraction of semivolatile organic compounds from high-efficiency particulate air (HEPA) filters. HEPA filters provide the final stage of containment on many exhaust systems in US Department of Energy (DOE) facilities by preventing the escape of chemical and radioactive materials entrained in the exhausted air. The efficiency of the filters is tested by the manufacturer and DOE using dioctylphthalate (DOP), a substance regulated by the US Environmental Protection Agency under the Resource Conservation and Recovery Act. Therefore, the filters must be analyzed for semivolatile organics before disposal. Ninety-eight acid, base, and neutral semivolatile organics were spiked onto blank HEPA material and extracted using SFE, Soxhlet, automated Soxhlet, and sonication techniques. The SFE conditions were optimized using a Dionex SFE-703 instrument. Average recoveries for the 98 semivolatile compounds are 82.7% for Soxhlet, 74.0% for sonication, 70.2% for SFE, and 62.9% for Soxtec. Supercritical fluid extraction reduces the extraction solvent volume to 10--15 mL, a factor of 20--30 less than Soxhlet and more than 5 times less than Soxtec and sonication. Extraction times of 30--45 min are used compared to 16--18 h for Soxhlet extraction

  12. Commonly used air filters fail to eliminate secondhand smoke induced oxidative stress and inflammatory responses.

    Science.gov (United States)

    Muthumalage, Thivanka; Pritsos, Karen; Hunter, Kenneth; Pritsos, Chris

    2017-07-01

    Secondhand smoke (SHS) causes approximately 50,000 deaths per year. Despite all the health warnings, smoking is still allowed indoors in many states exposing both workers and patrons to SHS on a daily basis. The opponents of smoking bans suggest that present day air filtration systems remove the health hazards of exposure to SHS. In this study, using an acute SHS exposure model, we looked at the impact of commonly used air filters (MERV-8 pleated and MERV-8 pleated activated charcoal) on SHS by assessing the inflammatory response and the oxidative stress response in C57BL/6 mice. In order to assess the inflammatory response, we looked at the tumor necrosis factor alpha (TNF-α) cytokine production by alveolar macrophages (AMs), and for the oxidative response, we quantified the products of lipid peroxidation and the total glutathione (tGSH) production in lung homogenates. Our results showed that SHS caused significant immune and oxidative stress responses. The tested filters resulted in only a modest alleviation of inflammatory and oxidative responses due to SHS exposure. Our data show that these air filters cannot eliminate the risk of SHS exposure and that a short-term exposure to SHS is sufficient to alter the inflammatory cytokine response and to initiate a complex oxidative stress response. Our results are consistent with the statement made by the Surgeon General's reports that there is no risk free level of exposure to SHS.

  13. Air intake device for at least one stand-by aggregate installed in an emergency power supply building

    International Nuclear Information System (INIS)

    Stoll, A.; Schilling, R.

    1980-01-01

    Stand-by aggregates are installed in an energency power supply building in order to ensure the cooling of nuclear power plants during accidents. In order to assure the stand-by aggregates to be supplied with combustion air also in the case of fire, each stand-by aggregate is provided with two intake pipes for the combustion air, which are horizontally lead through the building wall on the opposite sides of the energency power supply building. Fire valves are incorporated in the inlet pipes, and one of them will always close in the case of fire. (orig.) [de

  14. Filter system for purifying gas or air streams

    International Nuclear Information System (INIS)

    Ohlmeyer, M.; Wilhelm, J.

    1981-01-01

    A filter system is provided for purifying a gas stream by means of flowable or tricklable contact filter material, wherein the stream flows through the filter material and the filter material forms a movable bed. The system contains a filter chamber through which the filter material can flow and which is provided with an inlet opening and an outlet opening for the filter material between which the filter material is conveyed by gravity. The filter system includes deflection means for deflecting the stream , after a first passage of the stream through the filter bed to charge the filter bed for a first time, to a position above where the stream first passed through the filter bed and for conducting the stream at least once again transversely through the filter bed above the first charge so that the filter bed is charged a second time. The filter chamber contains a first opening where the stream enters the filter bed for the first time and is aligned with the deflection means, and a second opening aligned with the deflection means and above the first opening. The second opening is located where the stream leaves the filter bed for the second time, with a partial quantity of the gas stream being able to pass directly through the filter bed from the first opening to the second opening without going through the deflection means. The distance between the upper edge of the first opening and the lower edge of the second opening is at least twice the thickness of the filter chamber

  15. Energy and air emission effects of water supply.

    Science.gov (United States)

    Stokes, Jennifer R; Horvath, Arpad

    2009-04-15

    Life-cycle air emission effects of supplying water are explored using a hybrid life-cycle assessment For the typically sized U.S. utility analyzed, recycled water is preferable to desalination and comparable to importation. Seawater desalination has an energy and air emission footprint that is 1.5-2.4 times larger than that of imported water. However, some desalination modes fare better; brackish groundwater is 53-66% as environmentally intensive as seawater desalination. The annual water needs (326 m3) of a typical Californian that is met with imported water requires 5.8 GJ of energy and creates 360 kg of CO2 equivalent emissions. With seawater desalination, energy use would increase to 14 GJ and 800 kg of CO2 equivalent emissions. Meeting the water demand of California with desalination would consume 52% of the state's electricity. Supply options were reassessed using alternative electricity mixes, including the average mix of the United States and several renewable sources. Desalination using solar thermal energy has lower greenhouse gas emissions than that of imported and recycled water (using California's electricity mix), but using the U.S. mix increases the environmental footprint by 1.5 times. A comparison with a more energy-intensive international scenario shows that CO2 equivalent emissions for desalination in Dubai are 1.6 times larger than in California. The methods, decision support tool (WEST), and results of this study should persuade decision makers to make informed water policy choices by including energy consumption and material use effects in the decision-making process.

  16. Harmonic Detection at Initialization With Kalman Filter

    DEFF Research Database (Denmark)

    Hussain, Dil Muhammad Akbar; Imran, Raja Muhammad; Shoro, Ghulam Mustafa

    2014-01-01

    Most power electronic equipment these days generate harmonic disturbances, these devices hold nonlinear voltage/current characteristic. The harmonics generated can potentially be harmful to the consumer supply. Typically, filters are integrated at the power source or utility location to filter out...... the affect of harmonics on the supply. For the detection of these harmonics various techniques are available and one of that technique is the Kalman filter. In this paper we investigate that what are the consequences when harmonic detection system based on Kalman Filtering is initialized...

  17. High-efficiency particulate air filter test activities at the Department of Energy

    International Nuclear Information System (INIS)

    Bresson, J.F.

    1987-01-01

    For the past 2 years, test activities at the three Department of Energy HEPA Filter Test Facilities (FTFs) have been conducted under a unified set of operating standards intended to help achieve consistency in test methods and test results. Reviews of test operations are conducted at each FTF annually, and technical support and guidance are provided on request. Round Robin tests are conducted twice a year to compare penetration and resistance test results among the three FTFs. The FTFs prepare summary test data twice a year, and the data is analyzed for trends with respect to ongoing quality of HEPA filters in nuclear facilities. Data and conclusions from both the Round Robin tests and semiannual reports are discussed, the latter without reference to specific manufacturers. The new DOE standards include provisions for consideration and approval of new test aerosols or test methods, under closely controlled change procedures. Progress in obtaining DOE approval for DOS as a new aerosol, and for the Alternative Test System (ATS) developed by, and reported on by the LANL, as an approved new test method are discussed, as are 2 significant changes in standard NE-F-3-43, related to (a) toxicology test alternatives, and (b) the test aerosol definition. Finally, the emergence of new, higher flow rated HEPA filters and Ultra Low Particulate Air (ULPA) filters will impact DOE's design, procurement, testing and use of HEPA filters in the near future

  18. A Controlled Design of Ripple-Like Polyamide-6 Nanofiber/Nets Membrane for High-Efficiency Air Filter.

    Science.gov (United States)

    Zhang, Shichao; Liu, Hui; Zuo, Fenglei; Yin, Xia; Yu, Jianyong; Ding, Bin

    2017-03-01

    The filtration capacity of fibrous media for airborne particles is restricted by their thick diameter, low porosity, and limited frontal area. The ability to solve this problem would have broad technological implications for various air filtration applications; despite many past efforts, it remains a great challenge to achieve. Herein, a facile and scalable strategy to fabricate the ripple-like polyamide-6 nanofiber/nets (PA-6 NF/N) air filter via combining electrospinning/netting technique with receiving substrate design is demonstrated. This proposed approach allows the scaffold filaments to orderly embed into 2D PA-6 nanonets layer with Steiner-tree structures and nanoscale diameter of ≈20 nm, resulting in the ripple-like membrane with extremely small pore size, highly porous structure, and hugely extended frontal surface, by facilely adjusting its pleat span and pleat pitch. These unique structural advantages enable the ripple-like PA-6 NF/N filter to filtrate the ultrafine particles with high removal efficiency of 99.996%, low air resistance of 95 Pa, and robust quality factor of >0.11 Pa -1 ; using its superlight weight of 0.9 g m -2 and physical sieving manner. This approach has the potentialities to give rise to a novel generation of filter media displaying enhanced filtration capacity for various applications thanks to their nanoscale features and designed macrostructures. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. An experimental study on defrosting heat supplies and energy consumptions during a reverse cycle defrost operation for an air source heat pump

    International Nuclear Information System (INIS)

    Dong Jiankai; Deng Shiming; Jiang Yiqiang; Xia Liang; Yao Yang

    2012-01-01

    For a space heating air source heat pump (ASHP) unit, when its outdoor coil surface temperature is below both the air dew point temperature and the freezing point of water, frost will form on its outdoor coil surface. Frosting affects its operational performance and energy efficiency. Therefore, periodic defrosting is necessary. Currently, the most widely used standard defrosting method for ASHP units is reverse cycle defrost. The energy that should have been used for space heating is used to melt frost, vaporize the melted frost off outdoor coil surface and heat ambient air during defrosting. It is therefore necessary to study the sources of heat supplies and the end-uses of the heat supplied during a reverse cycle defrost operation. In this paper, firstly, an experimental setup is described and experimental procedures are detailed. This is followed by reporting the experimental results and the evaluation of defrosting efficiency for the experimental ASHP unit. Finally, an evaluation of defrosting heat supplies and energy consumptions during a revere cycle defrost operation for the experimental ASHP unit is presented. The experimental and evaluation results indicated that the heat supply from indoor air contributed to 71.8% of the total heat supplied for defrosting and 59.4% of the supplied energy was used for melting frost. The maximum defrosting efficiency could be up to 60.1%. - Highlights: ► Heat supply and consumption during reverse cycle defrost was experimentally studied. ► Indoor air contributed to >70% of total heat supply when indoor fan was turned on. ► ∼60% of the supplied energy was used for melting frost. ► Alternate heat supply other than indoor air should be explored.

  20. An evaluation of interventions for reducing the risk of PRRSV introduction to filtered farms via retrograde air movement through idle fans.

    Science.gov (United States)

    Alonso, Carmen; Otake, Satoshi; Davies, Peter; Dee, Scott

    2012-06-15

    Porcine reproductive and respiratory syndrome virus (PRRSV) is an economically significant pathogen of pigs that can be transported via the airborne route out to 9.1 km. To reduce this risk, large swine facilities have started to implement systems to filter contaminated incoming air. A proposed means of air filtration failure is the retrograde movement of air (back-drafting) from the external environment into the animal air space through non-filtered points such as idle wall fans; however, this risk has not been validated. Therefore, the purpose of this study was threefold: (1) to prove that PRRSV introduction via retrograde air movement through idle fans is a true risk; (2) to determine the minimum retrograde air velocity necessary to introduce PRRSV to an animal airspace from an external source; and (3) to evaluate the efficacy of different interventions designed to reduce this risk. A retrograde air movement model was used to test a range of velocities and interventions, including a standard plastic shutter, a plastic shutter plus a canvas cover, a nylon air chute, an aluminum shutter plus an air chute and a double shutter system. Results indicated that retrograde air movement is a real risk for PRRSV introduction to a filtered air space; however, it required a velocity of 0.76 m/s. In addition, while all the interventions designed to reduce this risk were superior when compared to a standard plastic shutter, significant differences were detected between treatments. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Washing method of filter

    International Nuclear Information System (INIS)

    Izumidani, Masakiyo; Tanno, Kazuo.

    1978-01-01

    Purpose: To enable automatic filter operation and facilitate back-washing operation by back-washing filters used in a bwr nuclear power plant utilizing an exhaust gas from a ventilator or air conditioner. Method: Exhaust gas from an exhaust pipe of an ventilator or air conditioner is pressurized in a compressor and then introduced in a back-washing gas tank. Then, the exhaust gas pressurized to a predetermined pressure is blown from the inside to the outside of a filter to thereby separate impurities collected on the filter elements and introduce them to a waste tank. (Furukawa, Y.)

  2. Magnetic evaluation of TSP-filters for air quality monitoring

    Science.gov (United States)

    Castañeda-Miranda, Ana Gabriela; Böhnel, Harald N.; Molina-Garza, Roberto S.; Chaparro, Marcos A. E.

    2014-10-01

    We present the magnetic properties of the powders collected by high volume total suspended particle air samplers used to monitor atmospheric pollution in Santiago de Querétaro, a city of one million people in central Mexico. The magnetic measurements have been combined with scanning electron microscopy observations and analysis, in order to characterize the particles captured in the filters as natural and anthropogenic. The main goal of the study is to test if magnetic measurements on the sampled atmospheric dust can be effective, low-cost, proxy to qualitatively estimate the air quality, complementing the traditional analytical methods. The magnetic properties of the powder collected in the filters have been investigated measuring the low field magnetic susceptibility, hysteresis loops, thermomagnetic curves, and isothermal remanent magnetization. The rock magnetism data have been supplemented by energy-dispersive X-ray spectroscopy analysis and Raman spectroscopy. It was found that the main magnetic carrier is low-Ti magnetite in the PSD range with a contribution from SP particles, and small but significant contributions from hematite, maghemite and goethite particles. Total suspended particles in the atmosphere during the monitored days ranged between about 30 and 280 μg/m3. Magnetic susceptibility values are well correlated with the independently determined total suspended particles concentration (R = 0.93), but particle concentration does not correlate as well with IRM1T. This may be attributed to contributions from SP and paramagnetic particles to the susceptibility signal, but not to the remanence. The effects of climate in particle size, composition and concentration were considered in terms of precipitation and wind intensity, but they are actually minor. The main effect of climate appears to be the removal of SP particles during rainy days. There is a contribution to air pollution from natural mineral sources, which we attribute to low vegetation cover

  3. Experimental study on two-stage air supply downdraft gasifier and dual fuel engine system

    Energy Technology Data Exchange (ETDEWEB)

    Nhuchhen, Daya Ram; Salam, P.A. [Asian Institute of Technology, Energy Field of Study, School of Environment Resource and Development, P. O. Box 4, Klong Luang, Pathumthani (Thailand)

    2012-06-15

    Biomass is a widely used renewable energy resource with net balanced carbon dioxide absorptions and emissions. An inefficient use of solid biomass in combustion process emits more gaseous pollutants, increasing the pollution level. Biomass gasification is one of the techniques to support efficient use of biomass. Multistage gasification is a method of gasification to improve quality of the producer gas in which two separate reactors are designed for separating gasification reactions. This study presents experimental results of gasification using Eucalyptus wood in a single long cylindrical reactor with two air supply ports, i.e., primary and secondary. The effect of different air supply rates on the heating values of the producer gas was studied. Optimum primary and secondary air supply rate of 100 and 80 l/min at equivalence ratio of 0.38 was observed with producer gas lower heating value of 4.72 MJ Nm{sup -3}. The performance of a diesel engine in the dual fuel mode was also evaluated. The overall gasifier engine system efficiency was 13.86 % at an electrical load of 10.54 kW{sub e} with specific energy consumption of 16.22 MJ kWh{sup -1}. The heat recovery system was designed and tested to recover heat from producer gas in the form of hot water. (orig.)

  4. Experimental study of filter cake formation on different filter media

    International Nuclear Information System (INIS)

    Saleem, M.

    2009-01-01

    Removal of particulate matter from gases generated in the process industry is important for product recovery as well as emission control. Dynamics of filtration plant depend on operating conditions. The models, that predict filter plant behaviour, involve empirical resistance parameters which are usually derived from limited experimental data and are characteristics of the filter media and filter cake (dust deposited on filter medium). Filter cake characteristics are affected by the nature of filter media, process parameters and mode of filter regeneration. Removal of dust particles from air is studied in a pilot scale jet pulsed bag filter facility resembling closely to the industrial filters. Limestone dust and ambient air are used in this study with two widely different filter media. All important parameters like pressure drop, gas flow rate, dust settling, are recorded continuously at 1s interval. The data is processed for estimation of the resistance parameters. The pressure drop rise on test filter media is compared. Results reveal that the surface of filter media has an influence on pressure drop rise (concave pressure drop rise). Similar effect is produced by partially jet pulsed filter surface. Filter behaviour is also simulated using estimated parameters and a simplified model and compared with the experimental results. Distribution of cake area load is therefore an important aspect of jet pulse cleaned bag filter modeling. Mean specific cake resistance remains nearly constant on thoroughly jet pulse cleaned membrane coated filter bags. However, the trend can not be confirmed without independent cake height and density measurements. Thus the results reveal the importance of independent measurements of cake resistance. (author)

  5. Requirements of office air conditioners. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, W

    1988-01-01

    New building designs and experiences gained in the past are reponsible for the considerable changes the requirements of air conditioners have gone through in recent years. Details are given on an exemplary air conditioning system designed for the Colonia Insurances building complex located in the city of Cologne. The ventilation requirements and hygienic conditions set out for air conditioned rooms call for outside air supplies, the careful selection of air intakes, and the filtering of intake air. Details are given on the efficiency and limits of combined natural window ventilation/artificial ventilation systems, the influence of window types, and the influence of building structures. The pressure conditions to be expected for larger building complexes in the case of natural ventilation should be assessed with the help of models put to wind tunnel tests.

  6. Mini-pleat filters for improved indoor air quality. Filtri a 'piccole pieghe' per una migliore qualita' dell'aria negli ambienti civili e negli impianti industriali

    Energy Technology Data Exchange (ETDEWEB)

    Zucchelli, D.

    1992-07-01

    Advanced manufacturing techniques applied to the fabrication of air filters have led to the creation of a high quality/efficiency mini-pleat filter which, however, has yet to see wide use in commercial space heating ventilation and air conditioning systems. Now, with greater attention being given to indoor air quality, these high performance filters should see greater market demand. This paper discusses the design and performance characteristics of mini-pleat filters and surveys the range of models currently available on the market.

  7. Formation and evolution of aerosols in filtered air and in natural air. Effect of radioactivity; Formation et evolution des aerosols dans l'air filtre et dans l'air naturel action de la radioactivite

    Energy Technology Data Exchange (ETDEWEB)

    Madelaine, G J [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-06-01

    Results are presented concerning the formation, the evolution, the coagulation and the electrical charge of aerosols which form in natural filtered air containing only gaseous impurities, under the influence of solar light (photolysis) and of radioactive disintegrations (radiolysis). The modifications brought about in the aerosol by an increase in the sulphur dioxide content and in the natural radioactive gas content are studied. The work is then repeated with non-filtered natural atmospheric air. A comparison is also made of the behaviour of non-radioactive and radioactive particles (active thoron deposit). In conclusion, the possible consequences of these phenomena on the origin and the size distribution of particles occurring in the atmosphere is considered. (author) [French] On expose les resultats obtenus sur la formation, l'evolution, la coagulation et la charge electrique des aerosols qui se forment dans l'air naturel filtre, ne contenant que des impuretes gazeuses, sous l'influence de la lumiere solaire (photolyse) et des desintegrations radioactives (radiolyse). On examine les modifications apportees a l'aerosol forme par l'augmentation de la teneur de l'air en anhydride sulfureux et en gaz radioactif naturel. Cette etude est ensuite reprise mais avec de l'air naturel atmospherique non filtre. On compare egalement le comportement des particules non radioactives et radioactives (depot actif du thoron). En conclusion, on examine les consequences que peuvent avoir ces phenomenes sur l'origine et la granulometrie des particules contenues dans l'atmosphere. (auteur)

  8. Qualification of box HEPA filters for nuclear applications

    International Nuclear Information System (INIS)

    Bergman, W.; Larsen, G.; Wilson, K.; Rainer, F.

    1995-03-01

    We have successfully completed qualification tests on high efficiency particulate air (HEPA) filters that are encapsulated within a box and manufactured by American Air Filters. The qualification tests are required by the American Society of Mechanical Engineers Standard ASME N509 and the U.S. Military Standard MIL-F-51068 for HEPA filters to be used in nuclear applications. The qualification tests specify minimum filter efficiencies following exposure to heated air, overpressure, and rough handling. Prior to this study, no box HEPA filters from any manufacturer had been qualified despite their wide-spread use in Department of Energy (DOE) facilities. Box HEPA filters are not addressed in any of the existing HEPA standards and only briefly discussed in the Nuclear Air Cleaning Handbook

  9. Miniaturized dielectric waveguide filters

    OpenAIRE

    Sandhu, MY; Hunter, IC

    2016-01-01

    Design techniques for a new class of integrated monolithic high-permittivity ceramic waveguide filters are presented. These filters enable a size reduction of 50% compared to air-filled transverse electromagnetic filters with the same unloaded Q-factor. Designs for Chebyshev and asymmetric generalised Chebyshev filter and a diplexer are presented with experimental results for an 1800 MHz Chebyshev filter and a 1700 MHz generalised Chebyshev filter showing excellent agreement with theory.

  10. Plants Clean Air and Water for Indoor Environments

    Science.gov (United States)

    2007-01-01

    Wolverton Environmental Services Inc., founded by longtime government environmental scientist B.C. "Bill" Wolverton, is an environmental consulting firm that gives customers access to the results of his decades of cutting-edge bioremediation research. Findings about how to use plants to improve indoor air quality have been published in dozens of NASA technical papers and in the book, "How to Grow Fresh Air: 50 Houseplants That Purify Your Home or Office." The book has now been translated into 12 languages and has been on the shelves of bookstores for nearly 10 years. A companion book, "Growing Clean Water: Nature's Solution to Water Pollution," explains how plants can clean waste water. Other discoveries include that the more air that is allowed to circulate through the roots of the plants, the more effective they are at cleaning polluted air; and that plants play a psychological role in welfare in that people recover from illness faster in the presence of plants. Wolverton Environmental is also working in partnership with Syracuse University, to engineer systems consisting of modular wicking filters tied into duct work and water supplies, essentially tying plant-based filters into heating, ventilation, and air conditioning (HVAC) systems. Also, the company has recently begun to assess the ability of the EcoPlanter to remove formaldehyde from interior environments. Wolverton Environmental is also in talks with designers of the new Stennis Visitor's Center, who are interested in using its designs for indoor air-quality filters

  11. High efficiency particulate air filter technology from 1980 to 1985 in the Central Electricity Generating Board

    International Nuclear Information System (INIS)

    Skledon, R.; Taylor, S.; Fern, C.; Stead, M.

    1986-01-01

    This paper examines at the Central Electricity Generating Board's methods of High Efficiency Particulate Air (1,700 m 3 /hr) filter testing from conception to the present day. The choice of the test and the early results are looked at followed by the development using new test equipment for checking ladderframe systems. The need for the drawing up of the Central Electricity Generating Board 743401 Standard for filter manufacture and its effect on full implementation is looked into. The advantages and disadvantages of our test procedures are reflected upon and the future developments in test methods and filters for use by the C.E.G.B. in their power stations are discussed. (author)

  12. The scope of inducing natural air supply via the façade

    NARCIS (Netherlands)

    van den Engel, P.J.W.; Kurvers, S.R.

    2017-01-01

    An overview is given of recent developments in the use of a system of inducing natural air supply via the façade in the Netherlands. This is followed by a review of the results of measurements from climate chamber experiments of its inducing ventilation performance and detailed insights gained

  13. Preliminary field evaluation of high efficiency steel filters

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W.; Larsen, G.; Lopez, R. [Lawrence Livermore National Laboratory, CA (United States)] [and others

    1995-02-01

    We have conducted an evaluation of two high efficiency steel filters in the exhaust of an uranium oxide grit blaster at the Y-12 Plant in Oak Ridge Tennessee. The filters were installed in a specially designed filter housing with a reverse air-pulse cleaning system for automatically cleaning the filters in-place. Previous tests conducted on the same filters and housing at LLNL under controlled conditions using Arizona road dust showed good cleanability with reverse air pulses. Two high efficiency steel filters, containing 64 pleated cartridge elements housed in the standard 2` x 2` x 1` HEPA frame, were evaluated in the filter test housing using a 1,000 cfm slip stream containing a high concentration of depleted uranium oxide dust. One filter had the pleated cartridges manufactured to our specifications by the Pall Corporation and the other by Memtec Corporation. Test results showed both filters had a rapid increase in pressure drop with time, and reverse air pulses could not decrease the pressure drop. We suspected moisture accumulation in the filters was the problem since there were heavy rains during the evaluations, and the pressure drop of the Memtec filter decreased dramatically after passing clean, dry air through the filter and after the filter sat idle for one week. Subsequent laboratory tests on a single filter cartridge confirmed that water accumulation in the filter was responsible for the increase in filter pressure drop and the inability to lower the pressure drop by reverse air pulses. No effort was made to identify the source of the water accumulation and correct the problem because the available funds were exhausted.

  14. Preliminary enviromagnetic comparison of the moss, lichen, and filter fabric bags to air pollution monitoring

    Directory of Open Access Journals (Sweden)

    Hanna Salo

    2014-08-01

    Full Text Available Air quality and anthropogenic air pollutants are usually investigated by passive biomonitoring which utilizes native species. Active biomonitoring, instead, refers to the use of transplants or bags in areas lacking native species. In Finland, the standardized moss bag technique SFS 5794 is commonly applied in active monitoring but there is still need for simpler and labor-saving sample material even on international scale. This article focuses on a preliminary comparison of the usability and collection efficiency of bags made of moss Sphagnum papillosum, lichen Hypogymnia physodes, and filter fabric (Filtrete™ in active biomonitoring of air pollutants around an industrial site in Harjavalta, SW Finland. The samples are analyzed with magnetic (i.e. magnetic susceptibility, isothermal remanent magnetization, hysteresis loop and hysteresis parameters methods highly suitable as a first-step tool for pollution studies. The results show that the highest magnetic susceptibility of each sample material is measured close to the industrial site. Furthermore, moss bags accumulate more magnetic material than lichen bags which, on the contrary, perform better at further distances. Filter fabric bags are tested only at 1 km sites indicating a good accumulation capability near the source. Pseudo-single-domain (PSD magnetite is identified as the main magnetic mineral in all sample materials and good correlations are found between different bag types. To conclude, all three materials effectively accumulate air pollutants and are suitable for air quality studies. The results of this article provide a base for later studies which are needed in order to fully determine a new, efficient, and easy sample material for active monitoring.

  15. Seismic assessment of air-cooled type emergency electric power supply system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    JNES initiated seismic assessment programs to develop seismic review criterions for the air-cooled system (diesel generator, gas turbine generator), which will be newly installed for enhancing the diversity of emergency electric power supply system. Five principal subjects are involved in the programs: two subjects for fiscal 2011 and three ones for fiscal 2012 and 2013. The summary of outcomes is as follows: 1) Past capacity test data and related technical issues (2011). Seismic capacity data obtained from past seismic shaking tests were investigated. 2) Test programs based on the investigation of system specification (2011). Design specifications for the air-cooled system were investigated. 3) Large Air Fin Cooler (AFC) one unit model seismic capacity test and quantitative seismic capacity evaluation. AFC one unit model seismic capacity tests were conducted and quantitative seismic capacities were evaluated. (author)

  16. Seismic assessment of air-cooled type emergency electric power supply system

    International Nuclear Information System (INIS)

    2013-01-01

    JNES initiated seismic assessment programs to develop seismic review criterions for the air-cooled system (diesel generator, gas turbine generator), which will be newly installed for enhancing the diversity of emergency electric power supply system. Five principal subjects are involved in the programs: two subjects for fiscal 2011 and three ones for fiscal 2012 and 2013. The summary of outcomes is as follows: 1) Past capacity test data and related technical issues (2011). Seismic capacity data obtained from past seismic shaking tests were investigated. 2) Test programs based on the investigation of system specification (2011). Design specifications for the air-cooled system were investigated. 3) Large Air Fin Cooler (AFC) one unit model seismic capacity test and quantitative seismic capacity evaluation. AFC one unit model seismic capacity tests were conducted and quantitative seismic capacities were evaluated. (author)

  17. The NYC native air sampling pilot project: using HVAC filter data for urban biological incident characterization.

    Science.gov (United States)

    Ackelsberg, Joel; Leykam, Frederic M; Hazi, Yair; Madsen, Larry C; West, Todd H; Faltesek, Anthony; Henderson, Gavin D; Henderson, Christopher L; Leighton, Terrance

    2011-09-01

    Native air sampling (NAS) is distinguished from dedicated air sampling (DAS) devices (eg, BioWatch) that are deployed to detect aerosol disseminations of biological threat agents. NAS uses filter samples from heating, ventilation, and air conditioning (HVAC) systems in commercial properties for environmental sampling after DAS detection of biological threat agent incidents. It represents an untapped, scientifically sound, efficient, widely distributed, and comparably inexpensive resource for postevent environmental sampling. Calculations predict that postevent NAS would be more efficient than environmental surface sampling by orders of magnitude. HVAC filter samples could be collected from pre-identified surrounding NAS facilities to corroborate the DAS alarm and delineate the path taken by the bioaerosol plume. The New York City (NYC) Native Air Sampling Pilot Project explored whether native air sampling would be acceptable to private sector stakeholders and could be implemented successfully in NYC. Building trade associations facilitated outreach to and discussions with property owners and managers, who expedited contact with building managers of candidate NAS properties that they managed or owned. Nominal NAS building requirements were determined; procedures to identify and evaluate candidate NAS facilities were developed; data collection tools and other resources were designed and used to expedite candidate NAS building selection and evaluation in Manhattan; and exemplar environmental sampling playbooks for emergency responders were completed. In this sample, modern buildings with single or few corporate tenants were the best NAS candidate facilities. The Pilot Project successfully demonstrated that in one urban setting a native air sampling strategy could be implemented with effective public-private collaboration.

  18. Performance of Chilled Beam with Radial Swirl Jet and Diffuse Ceiling Air Supply in Heating Mode

    DEFF Research Database (Denmark)

    Bertheussen, Bård; Mustakallio, Panu; Melikov, Arsen Krikor

    2013-01-01

    ). The room air temperature was kept at 21 °C. Tracer gas was used to simulate pollution from floor and desk. The experimental conditions comprised: 1) night time without heat sources in the room; the room air conditioning system was used to heat up the room; 2) heat load generated by an occupant (simulated...... by dressed thermal manikin) and a laptop; 3) heating by convectors positioned under the window (convectors used alone and convector used together with CSW supplying isothermal air for ventilation). The heat distribution provided by the systems was not effective compare to the distribution provided......The performance of diffuse ceiling air supply and chilled beam with swirl jet (CSW) in heating mode (winter situation) was studied and compared with regard to the generated indoor environment. An office mock-up with one occupant was simulated in a test room (4.5 x 3.95 x 3.5 m3 (L x W x H...

  19. Evaluation of self-contained HEPA filter

    Energy Technology Data Exchange (ETDEWEB)

    Arndt, T.E. [Westinghouse Hanford Company, Richland, WA (United States)

    1995-02-01

    This paper presents the results of an evaluation of a self-contained high-efficiency particulate air filter (SHEPA) used in nuclear applications. A SCHEPA consists of filter medium encapsulated in a casing that is part of the system boundary. The SCHEPA filter serves as a combination of filter housing and filter. The filter medium is attached directly to the casing using adhesive as a bonding agent. A cylindrical connection in the middle of the end caps connects the filter assembly to adjoining ductwork. The SCHEPA must perform the functions of a filter housing, filter frame, and filter. It was recognized that the codes and standards do not address the SCHEPA specifically. Therefore, the investigation evaluated the SCHEPA against current codes and standards related to the functional requirements of an air-cleaning system. The specific standards used are required by DOE Order 6430.1A{sup 1} and include ASME N509{sup 3}, ASME N510{sup 4}, ERDA 76-21{sup 5}, MIL-F-51068F{sup 6}, NFPA 90A, {sup 7} and NFPA 91{sup 8}. The evaluation does not address whether the SCHEPA as a standard (off-the-shelf) filter could be upgraded to meet the current code requirements for an air-cleaning unit. The evaluation also did not consider how the SCHEPA was used in a system (e.g., whether it was under positive or negative pressure or whether it served as an air inlet filter to prevent contamination releases under system pressurization). The results of the evaluation show that, the SCHEPA filter does not meet design, fabrication, testing, and documentation requirements of ASME N509{sup 3} and ASME N510{sup 4}. The paper will identify these deficiencies. Specific exhaust system requirements and application should be considered when an evaluation of the SCHEPA filter is being performed in existing systems. When new designs are being comtemplated, other types of HEPA filter housings can be used in lieu of the SCHEPA filter.

  20. Evaluation of air samplers and filter materials for collection and recovery of airborne norovirus.

    Science.gov (United States)

    Uhrbrand, K; Koponen, I K; Schultz, A C; Madsen, A M

    2018-04-01

    The aim of this study was to identify the most efficient sampling method for quantitative PCR-based detection of airborne human norovirus (NoV). A comparative experiment was conducted in an aerosol chamber using aerosolized murine norovirus (MNV) as a surrogate for NoV. Sampling was performed using a nylon (NY) filter in conjunction with four kinds of personal samplers: Gesamtstaubprobenahme sampler (GSP), Triplex-cyclone sampler (TC), 3-piece closed-faced Millipore cassette (3P) and a 2-stage NIOSH cyclone sampler (NIO). In addition, sampling was performed using the GSP sampler with four different filter types: NY, polycarbonate (PC), polytetrafluoroethylene (PTFE) and gelatine (GEL). The sampling efficiency of MNV was significantly influenced by both sampler and filter type. The GSP sampler was found to give significantly (P airborne NoV. The identification of a suitable NoV air sampler is an important step towards studying the association between exposure to airborne NoV and infection. © 2017 The Society for Applied Microbiology.

  1. Electric air filtration movie

    International Nuclear Information System (INIS)

    Bergman, W.; Jaeger, R.

    1984-01-01

    The use of electrostatics to improve the performance of conventional air filters has gained considerable attention in recent years. This interest is due to the higher efficiency and reduced pressure drop of electrically enhanced filters compared to conventional fibrous filters. This 30-minute movie presents a state of the art review of electric air filters in the United States with major illustrations provided by the research and development program at the Lawrence Livermore National Laboratory sponsored by the Department of Energy. The electric air filters described in this movie are mechanical air filters to which electrical forces have been added

  2. Quick-change filter cartridge

    Science.gov (United States)

    Rodgers, John C.; McFarland, Andrew R.; Ortiz, Carlos A.

    1995-01-01

    A quick-change filter cartridge. In sampling systems for measurement of airborne materials, a filter element is introduced into the sampled airstream such that the aerosol constituents are removed and deposited on the filter. Fragile sampling media often require support in order to prevent rupture during sampling, and careful mounting and sealing to prevent misalignment, tearing, or creasing which would allow the sampled air to bypass the filter. Additionally, handling of filter elements may introduce cross-contamination or exposure of operators to toxic materials. Moreover, it is desirable to enable the preloading of filter media into quick-change cartridges in clean laboratory environments, thereby simplifying and expediting the filter-changing process in the field. The quick-change filter cartridge of the present invention permits the application of a variety of filter media in many types of instruments and may also be used in automated systems. The cartridge includes a base through which a vacuum can be applied to draw air through the filter medium which is located on a porous filter support and held there by means of a cap which forms an airtight seal with the base. The base is also adapted for receiving absorbing media so that both particulates and gas-phase samples may be trapped for investigation, the latter downstream of the aerosol filter.

  3. Portable Filtered Air Suction System for Released Radioactive Gases Prevention under a Severe Accident of NPPs

    International Nuclear Information System (INIS)

    Gu, Beom W.; Choi, Su Y.; Rim, Chun T.

    2013-01-01

    In this paper, the portable filtered air suction system (PoFASS) for released radioactive gases prevention under a severe accident of NPP is proposed. This technology can prevent the release of the radioactive gases to the atmosphere and it can be more economical than FVCS because PoFASS can cover many NPPs with its high mobility. The conceptual design of PoFASS, which has the highest cost effectiveness and robustness to the environment condition such as wind velocity and precipitation, is suggested and the related previous research is introduced in this paper. The portable filtered air suction system (PoFASS) for released radioactive gases prevention can play a key role to mitigate the severe accident of NPP with its high cost effectiveness and robustness to the environment conditions. As further works, the detail design of PoFASS to fabricate a prototype for a demonstration will be proceeded. When released radioactive gases from the broken containment building in the severe accident of nuclear power plants (NPPs) such as the Chernobyl and Fukushima accidents occur, there are no ways to prevent the released radioactive gases spreading in the air. In order to solve this problem, several European NPPs have adopted the filtered vented containment system (FVCS), which can avoid the containment failure through a pressure relief capability to protect the containment building against overpressure. However, the installation cost of FVCS for a NPP is more than $10 million and this system has not been widely welcomed by NPP operating companies due to its high cost

  4. Ultra-wide tuning single channel filter based on one-dimensional photonic crystal with an air cavity

    Science.gov (United States)

    Zhao, Xiaodan; Yang, Yibiao; Chen, Zhihui; Wang, Yuncai; Fei, Hongming; Deng, Xiao

    2017-02-01

    By inserting an air cavity into a one-dimensional photonic crystal of LiF/GaSb, a tunable filter covering the whole visible range is proposed. Following consideration of the dispersion of the materials, through modulating the thickness of the air cavity, we demonstrate that a single resonant peak can shift from 416.1 to 667.3 nm in the band gap at normal incidence by means of the transfer matrix method. The research also shows that the transmittance of the channel can be maximized when the number of periodic LiF/GaSb layers on one side of the air defect layer is equal to that of the other side. When adding a period to both sides respectively, the full width at half maximum of the defect mode is reduced by one order of magnitude. This structure will provide a promising approach to fabricate practical tunable filters in the visible region with ultra-wide tuning range. Project supported by the National Natural Science Foundation of China (Nos. 61575138, 61307069, 51205273), and the Top Young Academic Leaders and the Outstanding Innovative Teams of Higher Learning Institutions of Shanxi.

  5. Summary of efficiency testing of standard and high-capacity high-efficiency particulate air filters subjected to simulated tornado depressurization and explosive shock waves

    International Nuclear Information System (INIS)

    Smith, P.R.; Gregory, W.S.

    1985-04-01

    Pressure transients in nuclear facility air cleaning systems can originate from natural phenomena such as tornadoes or from accident-induced explosive blast waves. This study was concerned with the effective efficiency of high-efficiency particulate air (HEPA) filters during pressure surges resulting from simulated tornado and explosion transients. The primary objective of the study was to examine filter efficiencies at pressure levels below the point of structural failure. Both standard and high-capacity 0.61-m by 0.61-m HEPA filters were evaluated, as were several 0.2-m by 0.2-m HEPA filters. For a particular manufacturer, the material release when subjected to tornado transients is the same (per unit area) for both the 0.2-m by 0.2-m and the 0.61-m by 0.61-m filters. For tornado transients, the material release was on the order of micrograms per square meter. When subjecting clean HEPA filters to simulated tornado transients with aerosol entrained in the pressure pulse, all filters tested showed a degradation of filter efficiency. For explosive transients, the material release from preloaded high-capacity filters was as much as 340 g. When preloaded high-capacity filters were subjected to shock waves approximately 50% of the structural limit level, 1 to 2 mg of particulate was released

  6. Evaluation of simplified ventilation system with direct air supply through the facade in a school in a cold climate

    Energy Technology Data Exchange (ETDEWEB)

    Mysen, M. [Norwegian Building Research Institute, Blindern, Oslo (Norway); Department of Energy and Process Technology, Norwegian University of Science and Technology (NTNU), Trondheim (Norway); Schild, P. G.; Hellstrand, V.; Thunshelle, K. [Norwegian Building Research Institute, Blindern, Oslo (Norway)

    2004-07-01

    Many educational buildings in industrialised countries have poor indoor climate, according to today's knowledge about the impact of indoor climate on well-being and productivity. Budget restrictions and practical limitations such as lack of space for central air handling units and ventilation ducts, have motivated the application of simplified ventilation systems in some schools, such as taking unconditioned supply air directly from the facade. One such school was recently evaluated in Norway. On cold days, thermal comfort in the classroom deteriorated due to cold down draught from the supply outlet. In addition, moist and fertile conditions for microbiological growth were observed in the air supply ductwork. On the other hand the same pupils are more satisfied with the school and have less sick building syndrome (SBS) symptoms during winter than summer. An improved control strategy with a temperature-compensated CO{sub 2} set-point for controlling the air flow is suggested. This could improve thermal comfort and reduce energy use without compromising perceived air quality (PAQ) during cold weather. Furthermore it could improve indoor air quality (IAQ) during warm weather with only a slight increase of energy use. Further evaluation of an improved solution is needed before such a ventilation concept can be recommended in cold climates. (author)

  7. The determination of nitrogen dioxide in ambient air with free hanging filters as passive samplers, and a new calibration method using fritted bubblers.

    Science.gov (United States)

    Heeres, Paul; Setiawan, Rineksa; Krol, Maarten Cornelis; Adema, Eduard Hilbrand

    2009-12-01

    This paper describes two new methods for the determination of NO(2) in the ambient air. The first method consists of free hanging filters with a diameter of 2.5 cm as passive samplers. The filters are impregnated with triethanolamine to bind NO(2). With standard colorimetrical analysis, the amount of NO(2) on the filters is determined. The second method is performed with fritted bubblers filled with Saltzman reagent, where, with a special procedure the absorption efficiencies of the bubblers are determined using ambient air, without the use of standard gases and electronic analytical instruments. The results of the bubblers are used to calibrate the free hanging filters. The two methods were applied simultaneously in the city of Yogyakarta, Indonesia. The methods are inexpensive and very well suited for use in low-budget situations. A characteristic of the free filter is the Sampling Volume, SV. This is the ratio of the amount of NO(2) on the filter and the ambient concentration. With the filter used in this study, the amount of triethanolamine and exposure time, the SV is 0.0166 m(3). The sampling rate (SR) of the filter, 4.6 cm(3)/s, is high. Hourly averaged measurements are performed for 15 hours per day in four busy streets. The measured amounts of NO(2) on the filters varied between 0.57 and 2.02 microg NO(2), at ambient air concentrations of 32 to 141 microg/m(3) NO(2). During the experiments the wind velocity was between 0.2 and 2.0 m/s, the relative humidity between 24 and 83 % and the temperature between 295 K and 311 K. These variations in weather conditions have no influence on the uptake of NO(2).

  8. Test procedure for calibration, grooming and alignment of the LDUA Purge Air Supply System

    International Nuclear Information System (INIS)

    Potter, J.D.

    1995-01-01

    The Light Duty Utility Arm (LDUA) is a remotely operated manipulator used to enter into underground waste tanks through one of the tank risers. National Electric Code requirements mandate that the in-tank portions of the LDUA be maintained at a positive pressure for entrance into a flammable atmosphere. The LDUA Purge Air Supply System (PASS) is a small, portable air compressor, which provides a constant low flow of instrument grade air for this purpose. This procedure is used to assure that the instrumentation and equipment comprising the PASS is properly adjusted in order to achieve its intended functions successfully

  9. Monolithic Integrated Ceramic Waveguide Filters

    OpenAIRE

    Hunter, IC; Sandhu, MY

    2014-01-01

    Design techniques for a new class of integrated monolithic high permittivity ceramic waveguide filters are presented. These filters enable a size reduction of 50% compared to air-filled TEM filters with the same unloaded Q-Factor. Designs for both chebyshev and asymmetric generalized chebyshev filter are presented, with experimental results for an 1800 MHz chebyshev filter showing excellent agreement with theory.

  10. Portland Energy Centre: Securing supply and clearing the air

    International Nuclear Information System (INIS)

    2003-02-01

    The rationale for, and benefits derivable from the proposed Portland natural gas-fired cogeneration plant, to be located beside the former Hearn power station near the Leslie Street Spit in Toronto, are discussed. The justification for and the single most important benefit promised by the proposed plant is that it could help Ontario achieve its coal phase-out target by displacing 100 per cent of the annual output of the Lakeview coal--fired power plant in Mississauga, as well as six per cent of the annual output of the Nanticoke coal-fired power plant, in total supplying about 10 per cent of Toronto's electricity needs and providing steam to heat several office towers in downtown Toronto. Other benefits discussed include substantially improved air quality, reduced incidence of asthma and heart attacks, a more reliable power supply for Toronto, some 500 new jobs during construction, and 25 to 35 permanent jobs to operate the plant. The Fact Sheet also offers suggestions on how to generate political support for this project in particular and for renewable power sources in general

  11. Measurement of gross alpha and beta in air filter samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Sudheendran, V.; Baburajan, A.; Gaikwad, R.H.; Ravi, P.M.; Tripathi, R.M.

    2015-01-01

    The determination of gross alpha and gross beta in particulate air filter samples was carried out by alpha, beta discrimination method using Liquid Scintillation Analyzer by setting the PSA value at 55 for 5 ml 0.1 HCl plus 15 ml of Ultima Gold AB cocktail by using 241 Am and 90 Sr/ 90 Y sources. The standardized method was compared with the gross alpha and gross beta activity determined by conventional method of direct counting with end window G.M. counter and ZnS (Ag). The minimum detectable activity of LSA method was found to be 9.3 mBq and 17.7 mBq for gross alpha and gross beta respectively for 6000 sec compared to the conventional method of 9.8 mBq and 189 mBq respectively at the same counting time. The result of analysis by both method indicate that the alpha, beta discrimination set up of LSA method is highly effective in the determination of low level alpha, beta activity in air filter samples. (author)

  12. Submerged Pond Sand Filter-A Novel Approach to Rural Water Supply

    DEFF Research Database (Denmark)

    Øhlenschlæger, Mia; Christensen, Sarah Christine Boesgaard; Bregnhøj, Henrik

    2016-01-01

    This study describes the new design and function of a modified version of a traditional slow sand filter. The Submerged Pond Sand Filter is built inside a pond and has a vertical as well as a horizontal flow of water through a sloped filter opening. The filter provides treated drinking water...... to a rural Indian village. The filter has functioned with minimal maintenance for five years without being subject to the typical scraping off and changing of sand as needed in traditional slow sand filters every few months. This five-year study showed bacterial removal efficiency of 97% on average...... to 10 CFU/100 mL on average compared to shorter pumping intervals (5 min). Though the treated water did not comply with the World Health Organization standards of 0 CFU/100 mL, the filter significantly improved water quality and provided one of the best sources of drinkable water in a water...

  13. Nonstandard usage of ASS-500 station filters for determination of ground-level air contamination

    International Nuclear Information System (INIS)

    Kozak, K.; Jasinska, M.; Kwiatek, W.; Mietelski, J.W.; Dutkiewicz, E.

    1998-01-01

    The work describes nonstandard application of filters from ASS-500 station for the determination of the element content in the samples collected by PIXE method. Determination of gamma radioactive isotopes and alpha radioactive plutonium is also reviewed. Authors conclude that ASS-500 workstation allows collection of representative samples from the ground level air. These samples are suitable for the complex analysis of industrial pollution

  14. Highly-stabilized power supply for synchrotron accelerators. High speed, low ripple power supply

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Kenji [Osaka Univ., Ibaraki (Japan). Research Center for Nuclear Physics; Kumada, Masayuki; Fukami, Kenji; Koseki, Shoichiro; Kubo, Hiroshi; Kanazawa, Toru

    1997-02-01

    In synchrotron accelerators, in order to utilize high energy beam effectively, those are operated by repeating acceleration and taking-out at short period. In order to accelerate by maintaining beam track stable, the tracking performance with the error less than 10{sup -3} in the follow-up of current is required for the power supply. Further, in order to maintain the intensity and uniformity of beam when it is taken out, very low ripple is required for output current. The power supply having such characteristics has been developed, and applied to the HIMAC and the SPring-8. As the examples of the application of synchrotrons, the accelerators for medical treatment and the generation of synchrotron radiation are described. As to the power supply for the deflection magnets and quadrupole magnets of synchrotron accelerators, the specifications of the main power supply, the method of reducing ripple, the method of improving tracking, and active filter control are reported. As to the test results, the measurement of current ripple and tracking error is shown. The lowering of ripple was enabled by common mode filter and the symmetrical connection of electromagnets, and high speed response was realized by the compensation for delay with active filter. (K.I.)

  15. Air filtration in HVAC systems

    CERN Document Server

    Ginestet, Alain; Tronville, Paolo; Hyttinen, Marko

    2010-01-01

    Air filtration Guidebook will help the designer and user to understand the background and criteria for air filtration, how to select air filters and avoid problems associated with hygienic and other conditions at operation of air filters. The selection of air filters is based on external conditions such as levels of existing pollutants, indoor air quality and energy efficiency requirements.

  16. Immobilized Filters for Air Filtration

    National Research Council Canada - National Science Library

    Mahle, John J; Zaiee, Saeed

    2002-01-01

    ... (settling performance) and attrition resistance. The fabricated filter samples will be analyzed in order to determine the physical and chemical factors affecting mechanical strength and chemical filtration...

  17. Incidence of polybrominated diphenyl ethers in central air conditioner filter dust from a new office building

    Energy Technology Data Exchange (ETDEWEB)

    Ni Honggang; Cao Shanping; Chang Wenjing [Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China); Zeng Hui, E-mail: huizeng0608@gmail.com [Shenzhen Key Laboratory of Circular Economy, Shenzhen Graduate School, Peking University, Shenzhen 518055 (China); Department of Ecology, College of Urban and Environmental Sciences, Peking University, Beijing 100871 (China)

    2011-07-15

    This study examined polybrominated diphenyl ethers (PBDEs) in central air conditioner filter (CACF) dust from a new office building in Shenzhen, China. Human exposure to PBDE via dust inhalation and ingestion were also estimated. PBDEs level in CACF dust was lower than those in the other countries and regions. Approximately 0.671 pg/kg bw/day PM{sub 2.5} (Particulate Matter up to 2.5 {mu}m in size) bounded {Sigma}{sub 15}PBDEs can be inhaled deep into the lungs and 4.123 pg/kg bw/day PM{sub 10} (Particulate Matter up to 10 {mu}m in size) bounded {Sigma}{sub 15}PBDEs tend to be deposited in the upper parts of the respiratory system. The average total intake of {Sigma}{sub 15}PBDEs via dust inhalation and ingestion for adults reached {approx}141 pg/kg bw/day in this building. This value was far below the reference dose (RfD) recommended by United States Environmental Protection Agency. Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than the old ones. - Highlights: > Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than that in the old ones. > PBDE emissions from indoor sources can be expected to continue for a long time as the PBDE-containing products in offices were to be kept many years. > The household consumer products, especially computers, are the main sources of PBDEs in central air conditioner filter dust. > Further studies are needed to fully understand the emission mechanism of PBDE from indoor consumer products. - PBDEs in central air conditioner filter dust from a new building were investigated

  18. Incidence of polybrominated diphenyl ethers in central air conditioner filter dust from a new office building

    International Nuclear Information System (INIS)

    Ni Honggang; Cao Shanping; Chang Wenjing; Zeng Hui

    2011-01-01

    This study examined polybrominated diphenyl ethers (PBDEs) in central air conditioner filter (CACF) dust from a new office building in Shenzhen, China. Human exposure to PBDE via dust inhalation and ingestion were also estimated. PBDEs level in CACF dust was lower than those in the other countries and regions. Approximately 0.671 pg/kg bw/day PM 2.5 (Particulate Matter up to 2.5 μm in size) bounded Σ 15 PBDEs can be inhaled deep into the lungs and 4.123 pg/kg bw/day PM 10 (Particulate Matter up to 10 μm in size) bounded Σ 15 PBDEs tend to be deposited in the upper parts of the respiratory system. The average total intake of Σ 15 PBDEs via dust inhalation and ingestion for adults reached ∼141 pg/kg bw/day in this building. This value was far below the reference dose (RfD) recommended by United States Environmental Protection Agency. Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than the old ones. - Highlights: → Human exposure to PBDEs via dust inhalation and ingestion in the new building is less than that in the old ones. → PBDE emissions from indoor sources can be expected to continue for a long time as the PBDE-containing products in offices were to be kept many years. → The household consumer products, especially computers, are the main sources of PBDEs in central air conditioner filter dust. → Further studies are needed to fully understand the emission mechanism of PBDE from indoor consumer products. - PBDEs in central air conditioner filter dust from a new building were investigated

  19. Modelling of air flow supply in a room at variable regime by using both K - E and spalart - allmaras turbulent model

    Science.gov (United States)

    Korbut, Vadim; Voznyak, Orest; Sukholova, Iryna; Myroniuk, Khrystyna

    2017-12-01

    The abstract is to The article is devoted to the decision of actual task of air distribution efficiency increasing with the help of swirl and spread air jets to provide normative parameters of air in the production apartments. The mathematical model of air supply with swirl and spread air jets in that type of apartments is improved. It is shown that for reachin of air distribution maximal efficiency it is necessary to supply air by air jets, that intensively extinct before entering into a working area. Simulation of air flow performed with the help of CFD FLUENT (Ansys FLUENT). Calculations of the equation by using one-parameter model of turbulence Spalart-Allmaras are presented. The graphical and the analytical dependences on the basis of the conducted experimental researches, which can be used in subsequent engineering calculations, are shown out. Dynamic parameters of air flow that is created due to swirl and spread air jets at their leakage at variable regime and creation of dynamic microclimate in a room has been determined. Results of experimental investigations of air supply into the room by air distribution device which creates swirl air jets for creation more intensive turbulization air flow in the room are presented. Obtained results of these investigations give possibility to realize engineer calculations of air distribution with swirl air jets. The results of theoretical researches of favourable influence of dynamic microclimate to the man are presented. When using dynamic microclimate, it's possible to decrease conditioning and ventilation system expenses. Human organism reacts favourably on short lasting deviations from the rationed parameters of air environment.

  20. Electrostatic air filters generated by electric fields

    International Nuclear Information System (INIS)

    Bergman, W.; Biermann, A.H.; Hebard, H.D.; Lum, B.Y.; Kuhl, W.D.

    1981-01-01

    This paper presents theoretical and experimental findings on fibrous filters converted to electrostatic operation by a nonionizing electric field. Compared to a conventional fibrous filter, the electrostatic filter has a higher efficiency and a longer, useful life. The increased efficiency is attributed to a time independent attraction between polarized fibers and charged, polarized particles and a time dependent attraction between charged fibers and charged, polarized particles. The charge on the fibers results from a dynamic process of charge accumulation due to the particle deposits and a charge dissipation due to the fiber conductivity

  1. Pressure transients across HEPA filters

    International Nuclear Information System (INIS)

    Gregory, W.; Reynolds, G.; Ricketts, C.; Smith, P.R.

    1977-01-01

    Nuclear fuel cycle facilities require ventilation for health and safety reasons. High efficiency particulate air (HEPA) filters are located within ventilation systems to trap radioactive dust released in reprocessing and fabrication operations. Pressure transients within the air cleaning systems may be such that the effectiveness of the filtration system is questioned under certain accident conditions. These pressure transients can result from both natural and man-caused phenomena: atmospheric pressure drop caused by a tornado or explosions and nuclear excursions initiate pressure pulses that could create undesirable conditions across HEPA filters. Tornado depressurization is a relatively slow transient as compared to pressure pulses that result from combustible hydrogen-air mixtures. Experimental investigation of these pressure transients across air cleaning equipment has been undertaken by Los Alamos Scientific Laboratory and New Mexico State University. An experimental apparatus has been constructed to impose pressure pulses across HEPA filters. The experimental equipment is described as well as preliminary results using variable pressurization rates. Two modes of filtration of an aerosol injected upstream of the filter is examined. A laser instrumentation for measuring the aerosol release, during the transient, is described

  2. Loading capacity of various filters for lithium fire generated aerosols

    International Nuclear Information System (INIS)

    Jeppson, D.W.; Barreca, J.R.

    1980-01-01

    The lithium aerosol loading capacity of a prefilter, HEPA filters and a sand and gravel bed filter was determined. The test aerosol was characterized and was generated by burning lithium in an unlimited air atmosphere. Correlation to sodium aerosol loading capacities were made to relate existing data to lithium aerosol loadings under varying conditions. This work is being conducted in support of the fusion reactor safety program. The lithium aerosol was generated by burning lithium pools, up to 45 kgs, in a 340 m 3 low humidity air atmosphere to supply aerosol to recirculating filter test loops. The aerosol was sampled to determine particle size, mass concentrations and chemical species. The dew point and gas concentrations were monitored throughout the tests. Loop inlet aerosol mass concentrations ranged up to 5 gr/m 3 . Chemical compounds analyzed to be present in the aerosol include Li 2 O, LiOH, and Li 2 CO 3 . HEPA filters with and without separators and a prefilter and HEPA filter in series were loaded with 7.8 to 11.1 kg/m 2 of aerosol at a flow rate of 1.31 m/sec and 5 kPa pressure drop. The HEPA filter loading capacity was determined to be greater at a lower flow rate. The loading capacity increased from 0.4 to 2.8 kg by decreasing the flow rate from 1.31 to 0.26 m/sec for a pressure drop of 0.11 kPa due to aerosol buildup. The prefilter tested in series with a HEPA did not increase the total loading capacity significantly for the same total pressure drop. Separators in the HEPA had only minor effect on loading capacity. The sand and gravel bed filter loaded to 0.50 kg/m 2 at an aerosol flow rate of 0.069 m/sec and final pressure drop of 6.2 kPa. These loading capacities and their dependence on test variables are similar to those reported for sodium aerosols except for the lithium aerosol HEPA loading capacity dependence upon flow rate

  3. Investigations of 131I concentration in indoor air using charcoal filters and gamma spectroscopy

    International Nuclear Information System (INIS)

    Fischer, H.W.; Pittauerova, D.; Foschepoth, S.; Poppe, B.

    2008-01-01

    Full text: Radiation protection standards require the recording of staff radiation dose in nuclear medicine thyroid radiotherapy. A commonly used method measures the 131 I thyroid activity externally with a gamma detector, followed by calculation of the committed equivalent thyroid dose. The main disadvantages are the low sensitivity and the uncertainty of the time of uptake, which can only be compensated by long measurement times and short measurement intervals. The measurements have to be applied to all staff members. An alternative can be provided by the measurement of the cumulated concentration of 131 I in indoor air using charcoal filters. The filters are placed in patient rooms at representative locations, exposed for several days and then investigated for absorbed 131 I activity. Both above mentioned disadvantages can be overcome: the measurement records the cumulated concentration history of the room and the obtained value can be used for dose calculation for all staff members knowing their working history. Standard charcoal filters (PicoRad vials, Accustar Labs, normally used for indoor radon measurements) were placed into patient rooms in a thyroid therapy department and exposed to room air for 72 hours. The vials were then subjected to high resolution low level gamma spectroscopy using a high purity germanium (hpGe) detector (50% relative efficiency, 10 cm lead shielding). Absolute activity determination was based on the net count rate in the 364 keV gamma peak and absolute counting efficiency obtained mathematically from detector and vial geometry using the commercial Labsocs (Canberra Inc.) program. Using the mean air activity/vial activity calibration factor obtained in a similar study pioneering this application, but using liquid scintillation spectroscopy as detection method (F. Jimenez et al, 2nd. European IRPA Congress, Paris 2006), mean air concentrations between 0.09 and 2.01 Bq/m 3 were found. The data correlated well with patient administered

  4. Investigation and deactivation of B Plant HEPA filters

    International Nuclear Information System (INIS)

    Roege, P.E.

    1997-01-01

    This paper describes the integrated approach used to manage environmental, safety, and health considerations related to the B Plant canyon exhaust air filters at the US Department of Energy (DOE) Hanford Site. The narrative illustrates the development and implementation of integrated safety management as applied to a facility and its systems undergoing deactivation. During their lifetime, the high efficiency particulate air (HEPA) filters prevented the release of significant quantities of radioactive materials into the air. As the material in B Plant AVESF accumulated on the filters, it created an unusual situation. Over long periods of time, the radiation dose from the filter loading, combined with aging and chemical exposure actually degrade those filters which were intended to protect against any release to the environment

  5. Behavior of HEPA filters under high humidity airflows

    International Nuclear Information System (INIS)

    Ricketts, C.I.

    1992-10-01

    To help determine and improve the safety margins of High Efficiency Particulate Air (HEPA) filter units in nuclear facilities under possible accident conditions, the structural limits and failure mechanisms of filter in high-humidity airflows were established and the fundamental physical phenomena underlying filter failure or malfunction in humid air were identified. Empirical models for increases in filter pressure drop with time in terms of the relevant airstream parameters were also developed. The weaknesses of currently employed humidity countermeasures used in filter protection are discussed and fundamental explanations for reported filter failures in normal service are given. (orig./DG) [de

  6. Remotely operated top loading filter housing

    International Nuclear Information System (INIS)

    Ross, M.J.; Carter, J.A.

    1989-01-01

    A high-efficiency particulate air (HEPA) filter system was developed for the Fuel Processing Facility at the Idaho Chemical Processing Plant. The system utilizes commercially available HEPA filters and allows in-cell filters to be maintained using operator-controlled remote handling equipment. The remote handling tasks include transport of filters before and after replacement, removal and replacement of the filter from the housing, and filter containment

  7. Air conditioning system and component therefore distributing air flow from opposite directions

    Science.gov (United States)

    Obler, H. D.; Bauer, H. B. (Inventor)

    1974-01-01

    The air conditioning system comprises a plurality of separate air conditioning units coupled to a common supply duct such that air may be introduced into the supply duct in two opposite flow directions. A plurality of outlets such as registers or auxiliary or branch ducts communicate with the supply duct and valve means are disposed in the supply duct at at least some of the outlets for automatically channelling a controllable amount of air from the supply duct to the associated outlet regardless of the direction of air flow within the supply duct. The valve means comprises an automatic air volume control apparatus for distribution within the air supply duct into which air may be introduced from two opposite directions. The apparatus incorporates a freely swinging movable vane in the supply duct to automatically channel into the associated outlet only the deflected air flow which has the higher relative pressure.

  8. Capturing PM2.5 Emissions from 3D Printing via Nanofiber-based Air Filter.

    Science.gov (United States)

    Rao, Chengchen; Gu, Fu; Zhao, Peng; Sharmin, Nusrat; Gu, Haibing; Fu, Jianzhong

    2017-09-04

    This study investigated the feasibility of using polycaprolactone (PCL) nanofiber-based air filters to capture PM2.5 particles emitted from fused deposition modeling (FDM) 3D printing. Generation and aggregation of emitted particles were investigated under different testing environments. The results show that: (1) the PCL nanofiber membranes are capable of capturing particle emissions from 3D printing, (2) relative humidity plays a signification role in aggregation of the captured particles, (3) generation and aggregation of particles from 3D printing can be divided into four stages: the PM2.5 concentration and particles size increase slowly (first stage), small particles are continuously generated and their concentration increases rapidly (second stage), small particles aggregate into more large particles and the growth of concentration slows down (third stage), the PM2.5 concentration and particle aggregation sizes increase rapidly (fourth stage), and (4) the ultrafine particles denoted as "building unit" act as the fundamentals of the aggregated particles. This work has tremendous implications in providing measures for controlling the particle emissions from 3D printing, which would facilitate the extensive application of 3D printing. In addition, this study provides a potential application scenario for nanofiber-based air filters other than laboratory theoretical investigation.

  9. Evaluation of multistage filtration to reduce sand filter exhaust activity

    International Nuclear Information System (INIS)

    Zippler, D.B.

    1975-01-01

    Air from the Savannah River Plant Fuel Reprocessing facilities is filtered through deep bed sand filters consisting of 8 1 / 2 feet of gravel and sand. These filters have performed satisfactorily for the past 18 years in maintaining radioactive release levels to a minimum. The apparent filter efficiency has been determined for many years by measurements of the quantity of radioactivity in the air stream before and after the filter. Such tests have indicated efficiencies of 99.9 percent or better. Even with sand filter efficiency approaching a single stage HEPA filter, new emphasis on further reduction in release of plutonium activity to the environment prompted a study to determine what value backup HEPA filtration could provide. To evaluate the specific effect additional HEPA filtration would have on the removal of Pu from the existing sand filter exhaust stream, a test was conducted by passing a sidestream of sand-filtered air through a standard 24 x 24 x 11 1 / 2 in. HEPA filter. Isokinetic air samples were withdrawn upstream and downstream of the HEPA filter and counted for alpha activity. Efficiency calculations indicated that backup HEPA filtration could be expected to provide an additional 99 percent removal of the Pu activity from the present sand-filter exhaust. (U.S.)

  10. Chemical Characterization of the Indoor Air Quality of a University Hospital: Penetration of Outdoor Air Pollutants.

    Science.gov (United States)

    Scheepers, Paul T J; Van Wel, Luuk; Beckmann, Gwendolyn; Anzion, Rob B M

    2017-05-08

    For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ). The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two outdoor locations and source samples were collected from a helicopter and an emergency power supply. Volatile organic compounds (VOC), acrolein, formaldehyde, nitrogen dioxide (NO₂), respirable particulate matter (PM-4.0 and PM-2.5) and their respective benz(a)pyrene contents were determined over a period of two weeks. Time-weighted average concentrations of NO₂ (4.9-17.4 μg/m³) and formaldehyde (2.5-6.4 μg/m³) were similar on all indoor and outdoor locations. The median concentration VOC in indoor air was 119 μg/m³ (range: 33.1-2450 μg/m³) and was fivefold higher in laboratories (316 μg/m³) compared to offices (57.0 μg/m³). PM-4.0 and benzo(a)pyrene concentration were lower in buildings serviced by a >99.95% efficiency particle filter, compared to buildings using a standard 80-90% efficiency filter ( p engines to any of the IAQ parameters measured in this study. Chemical IAQ was primarily driven by known indoor sources and activities.

  11. Capturing PM2.5 emissions from 3D printing via nanofiber-based air filter

    OpenAIRE

    Rao, Chengchen; Gu, Fu; Zhao, Peng; Sharmin, Nusrat; Gu, Haibing; Fu, Jianzhong

    2017-01-01

    This study investigated the feasibility of using polycaprolactone (PCL) nanofiber-based air filters to capture PM2.5 particles emitted from fused deposition modeling (FDM) 3D printing. Generation and aggregation of emitted particles were investigated under different testing environments. The results show that: (1) the PCL nanofiber membranes are capable of capturing particle emissions from 3D printing, (2) relative humidity plays a signification role in aggregation of the captured particles, ...

  12. Collection of aerosols in high efficiency particulate air filters

    International Nuclear Information System (INIS)

    Pratt, R.P.; Green, B.L.

    1987-01-01

    The investigation of the performance of HEPA filters of both minipleat and conventional deep pleat designs has continued at Harwell. Samples of filters from several manufacturers have been tested against the UKAEA/BNF plc filter purchasing specification. No unexpected problems have come to light in these tests, apart from some evidence to suggest that although meeting the specification minipleat filters are inherently weaker in burst strength terms than conventional filters. In addition tests have been carried out to investigate the dust loading versus pressure drop characteristics of both designs of filters using a range of test dusts - ASHRAE dust, carbon black, BS 2831 No. 2 test dust and sodium chloride. In parallel with laboratory test work a more fundamental study on the effects of geometric arrangement of filter media within the filter frame has been carried out on behalf of the UKAEA by Loughborough University. The results of this study has been the development of a mathematical model to predict the dust load versus pressure drop characteristic as a function of filter media geometry. This has produced good agreement with laboratory test results using a challenge aerosol in the 1-5 μm size range. Further observations have been made to enhance understanding of the deposition of aerosols within the filter structure. The observations suggest that the major influence on dust loading is the depth of material collected in the flow channel as a surface deposition, and this explains the relatively poor performance of the minipleat design of filter

  13. Polish apparatus for the measurement of dust content in the air of a mine

    Energy Technology Data Exchange (ETDEWEB)

    Krzystolik, P; Piskorska-Kalisz, Z

    1981-01-01

    Some characteristics are presented of the apparatus for the control of the dust content of air in coal mines, developed by the main Polish Institute of Mining Affairs. The Barbara 3 A gravitational dust meter has: volumetric velocity of suction of air of 5 cubic decimeters per minute; the mass is 5.8 kilograms; the range of the determined concentration of dust is from 0.5 to 1 grams per cubic meters; the length of the operation with the supply from four silver-zinc accumulator elements is eight hours; the selector of dust particles is a platy elutriator or a microcyclone; a membrane type of filter, an explosively danger actuation. The Barbar 4 gravitation dust meter has: volumetric velocity of air suction of 10, 20, 50, or 100 cubic decimeters per minute; supply from the network of compressed air; the mass is about eight kilograms; the selector of dust particles is a microcyclone; the filter is a membrane or is in the form of a layer of salicylic acid, placed between two nets. Both dust meters are designated for the determination of dust content as well as the content of finely dispersed dust particles. The mass of the selected specimen of dust is adequate also for the determination of the content of silica, as well as for other special analyses.

  14. Calculation methods for air supply design in industrial facilities. Literature review

    Energy Technology Data Exchange (ETDEWEB)

    Hagstroem, K; Siren, K; Zhivov, A M

    1999-09-01

    The objectives of air distribution systems for warm air heating, ventilating, and air-conditioning are to create the proper thermal environment conditions in the occupied zone (combination of temperature, humidity, and air movement), and to control vapor and air born particle concentration within the target levels set by the process requirements and/or threshold limit values based on health effects, fire and explosion prevention, or other considerations. HVAC systems designs are constrained by existing codes, standards, and guidelines, which specify some minimum requirements for the HVAC system elements, occupant`s and process environmental quality and safety. There is a variety of different methods consulting engineers use to design room air diffusion and to select and size air diffusers, such as assumption of perfect mixing, design methods employing the empirical relations determined through research, such as the air diffusion performance index (ADPI), air jet theory and computational fluid dynamics (CFD) codes. Air supplied into the room through the various types of outlets (grills, ceiling mounted air diffusers, perforated panels etc.), is distributed by turbulent air jets. In mixing type air distribution systems, these air jets are the primary factor affecting room air motion. Numerous theoretical and experimental studies that developed a solid base for turbulent air jets theory were conducted concurrently in different countries (Germany, Sweden, Russia, U.K., USA) from the 1930`s through the 1980`s. Design methods based on air jet theory allows for the prediction of extreme values of air velocities and air temperatures in the occupied zone of empty spaces. Current air jet theory techniques account for the effects of buoyancy, confinement, jets interaction. For many conditions of jet discharge, it is possible to analyze jet performance and determine: the angle of divergence of the jet boundary; the velocity patterns along heated or chilled the jet axis; the

  15. Comparison of high efficiency particulate filter testing methods

    International Nuclear Information System (INIS)

    1985-01-01

    High Efficiency Particulate Air (HEPA) filters are used for the removal of submicron size particulates from air streams. In nuclear industry they are used as an important engineering safeguard to prevent the release of air borne radioactive particulates to the environment. HEPA filters used in the nuclear industry should therefore be manufactured and operated under strict quality control. There are three levels of testing HEPA filters: i) testing of the filter media; ii) testing of the assembled filter including filter media and filter housing; and iii) on site testing of the complete filter installation before putting into operation and later for the purpose of periodic control. A co-ordinated research programme on particulate filter testing methods was taken up by the Agency and contracts were awarded to the Member Countries, Belgium, German Democratic Republic, India and Hungary. The investigations carried out by the participants of the present co-ordinated research programme include the results of the nowadays most frequently used HEPA filter testing methods both for filter medium test, rig test and in-situ test purposes. Most of the experiments were carried out at ambient temperature and humidity, but indications were given to extend the investigations to elevated temperature and humidity in the future for the purpose of testing the performance of HEPA filter under severe conditions. A major conclusion of the co-ordinated research programme was that it was not possible to recommend one method as a reference method for in situ testing of high efficiency particulate air filters. Most of the present conventional methods are adequate for current requirements. The reasons why no method is to be recommended were multiple, ranging from economical aspects, through incompatibility of materials to national regulations

  16. Performance of HEPA filters under hot dynamic conditions

    International Nuclear Information System (INIS)

    Frankum, D.P.; Costigan, G.

    1995-01-01

    Accidents in nuclear facilities involving fires may have implications upon the ventilation systems where high efficiency particulate air (HEPA) filters are used to minimise the airborne release of radioactive or toxic particles. The Filter Development Section at Harwell Laboratory has been investigating the effect of temperature on the performance of HEPA filters under hot dynamic conditions[ 1 ] for a number of years. The test rig is capable of delivering air flows of 10001/s (at ambient conditions) at temperatures up to 500 degrees C, where measurements of the penetration and pressure drop across the filter are obtained. This paper reports the experiments on different constructions of HEPA filters; rectangular and circular. The filters were tested at an air temperature of 200 degrees C for up to 48 hours at the rated airflow to assess their performance. The penetration measurements for rectangular filters were observed to be below 0.021% after prolonged operation. In a number of cases, holes appeared along the pleat creases of circular filters although the penetration remained below 1%. The sealing gasket for these filters was noted to deform with temperature, permitting a leakage path. A prototype high strength circular filter was evaluated at temperatures of up to 400 degrees C with a penetration less than 0.65%

  17. Performance of HEPA filters under hot dynamic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Frankum, D.P.; Costigan, G. [AEA Technology, Oxfordshire (United Kingdom)

    1995-02-01

    Accidents in nuclear facilities involving fires may have implications upon the ventilation systems where high efficiency particulate air (HEPA) filters are used to minimise the airborne release of radioactive or toxic particles. The Filter Development Section at Harwell Laboratory has been investigating the effect of temperature on the performance of HEPA filters under hot dynamic conditions[{sub 1}] for a number of years. The test rig is capable of delivering air flows of 10001/s (at ambient conditions) at temperatures up to 500{degrees}C, where measurements of the penetration and pressure drop across the filter are obtained. This paper reports the experiments on different constructions of HEPA filters; rectangular and circular. The filters were tested at an air temperature of 200{degrees}C for up to 48 hours at the rated airflow to assess their performance. The penetration measurements for rectangular filters were observed to be below 0.021% after prolonged operation. In a number of cases, holes appeared along the pleat creases of circular filters although the penetration remained below 1%. The sealing gasket for these filters was noted to deform with temperature, permitting a leakage path. A prototype high strength circular filter was evaluated at temperatures of up to 400{degrees}C with a penetration less than 0.65%.

  18. Factors Influencing HEPA Filter Performance

    International Nuclear Information System (INIS)

    Parsons, M.S.; Waggoner, Ch.A.

    2009-01-01

    Properly functioning HEPA air filtration systems depend on a variety of factors that start with the use of fully characterized challenge conditions for system design and then process control during operation. This paper addresses factors that should be considered during the design phase as well as operating parameters that can be monitored to ensure filter function and lifetime. HEPA filters used in nuclear applications are expected to meet design, fabrication, and performance requirements set forth in the ASME AG-1 standard. The DOE publication Nuclear Air Cleaning Handbook (NACH) is an additional guidance document for design and operation HEPA filter systems in DOE facilities. These two guidelines establish basic maximum operating parameters for temperature, maximum aerosol particle size, maximum particulate matter mass concentration, acceptable differential pressure range, and filter media velocity. Each of these parameters is discussed along with data linking variability of each parameter with filter function and lifetime. Temporal uncertainty associated with gas composition, temperature, and absolute pressure of the air flow can have a direct impact on the volumetric flow rate of the system with a corresponding impact on filter media velocity. Correlations between standard units of flow rate (standard meters per minute or cubic feet per minute) versus actual units of volumetric flow rate are shown for variations in relative humidity for a 70 deg. C to 200 deg. C temperature range as an example of gas composition that, uncorrected, will influence media velocity. The AG-1 standard establishes a 2.5 cm/s (5 feet per minute) ceiling for media velocities of nuclear grade HEPA filters. Data are presented that show the impact of media velocities from 2.0 to 4.0 cm/s media velocities (4 to 8 fpm) on differential pressure, filter efficiency, and filter lifetime. Data will also be presented correlating media velocity effects with two different particle size

  19. The determination of nitrogen dioxide in ambient air with free hanging filters as passive samplers, and a new calibration method using fritted bubblers

    NARCIS (Netherlands)

    Heeres, P.; Setiawan, R.; Krol, M.C.; Adema, E.H.

    2009-01-01

    This paper describes two new methods for the determination of NO2 in the ambient air. The first method consists of free hanging filters with a diameter of 2.5 cm as passive samplers. The filters are impregnated with triethanolamine to bind NO2. With standard colorimetrical analysis, the amount of

  20. Device with Complex System for Heat Utilization and Reduction of Hazardous Air Emissions

    Directory of Open Access Journals (Sweden)

    O. V. Kascheeva

    2012-01-01

    Full Text Available Investigations concern heat utilization and reduction of hazardous emissions occurring in residential buildings and accompanying operation of a great number of industrial enterprises in particular heat and power objects, and firstly, heat-generating units of small power located in densely populated residential areas without centralized heat supply.The investigation target is to reduce cost of heat produced by independent system of building heat supply, reduction of air pollution  due to hazardous gas emissions and reduction of heat pollution of the environment as a result of building ventilation system operation, ventilation of their internal and external sewerage network and higher reliability of their operation.The target is achieved because the device with complex system for heat utilization and reduction of hazardous air emissions has additionally an assembly tank for mixing flue gases, ventilation emissions and atmospheric air, heat pump. Evaporation zone of the pump is a condensator of the gas mixture and its condensate zone contains a heat supply line for a heat consumer. The line is equipped with assembling  and distributing collectors, pipeline connecting the heat supply line with the system of direct and return delivery water from a boiler house, a separator for division of liquid and gaseous mixture phases, neutralizing devices for separate reduction of concentrations of hazardous and odorous substances being released in gaseous and liquid portions of the mixture, a pipeline for periodic supply of air with higher concentration of hazardous and odorous substances in the boiler furnace. The supplied air is obtained as a result of its passing through gas filters at their regeneration when their exchange capacity is exhausted.

  1. Nuclear air cleaning

    International Nuclear Information System (INIS)

    Bellamy, R.R.

    1994-01-01

    This report briefly describes the history of the use of high- efficiency particulate air filters for air cleaning at nuclear installations in the United States and discusses future uses of such filters

  2. The decrease of the energy performance for the soiling of the air filters in gas turbines; Disminucion de la eficiencia energetica por ensuciamiento de filtros de aire en turbinas de gas

    Energy Technology Data Exchange (ETDEWEB)

    Romero Paredes, H.; Ambriz, J. J.; Vargas, M.; Godinez, M.; Gomez, F.; Valdez, L.; Pantoja, G. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Mexico D. F. (Mexico)

    1995-12-31

    The object of this paper is to study the effect in the turbine output of a gas turbine of the conditions of the compressor air inlet in going through a series of filters. The algorithm for the calculation of the energy losses due to the variation of the pressure drop caused by the filters according to their cleanliness condition. In the first part the series of variables that affect the gas turbines performance are exemplified, afterwards the characteristics of the air flow into a turbine are presented as well as their effects on the system. Later on, the results obtained of the system simulation are presented and compared with a real case. From the results it can be determined, that depending on the system and on the environment conditions the efficiency drop might be up to 3%, in accordance with the filters cleanliness. The maintenance periods strongly depend on the air quality variations at the filter house inlet in the zone where the power plant is located. [Espanol] El presente trabajo tiene por objetivo estudiar el efecto en la potencia generada en una turbina de gas de las condiciones de entrada del aire al compresor de una turbina de gas al pasar por un conjunto de filtros. Se presenta el algoritmo para la determinacion de las perdidas energeticas debidas a la variacion de la caida de presion generada por los filtros de acuerdo con su estado de limpieza. En la primera parte se ejemplifica el conjunto de variables que influyen en la eficiencia de las turbinas de gas, posteriormente se mencionan las caracteristicas de flujo de aire hacia una turbina y se muestran los efectos sobre el sistema. A continuacion se presentan los resultados obtenidos de la simulacion del sistema y se comparan con un caso real. De los resultados se puede apreciar que, dependiendo del sistema y de las condiciones ambientales el decremento en la eficiencia puede ser hasta del 3% en funcion del nivel de limpieza de los filtros. Los periodos de mantenimiento dependen fuertemente de las

  3. The decrease of the energy performance for the soiling of the air filters in gas turbines; Disminucion de la eficiencia energetica por ensuciamiento de filtros de aire en turbinas de gas

    Energy Technology Data Exchange (ETDEWEB)

    Romero Paredes, H; Ambriz, J J; Vargas, M; Godinez, M; Gomez, F; Valdez, L; Pantoja, G [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Mexico D. F. (Mexico)

    1996-12-31

    The object of this paper is to study the effect in the turbine output of a gas turbine of the conditions of the compressor air inlet in going through a series of filters. The algorithm for the calculation of the energy losses due to the variation of the pressure drop caused by the filters according to their cleanliness condition. In the first part the series of variables that affect the gas turbines performance are exemplified, afterwards the characteristics of the air flow into a turbine are presented as well as their effects on the system. Later on, the results obtained of the system simulation are presented and compared with a real case. From the results it can be determined, that depending on the system and on the environment conditions the efficiency drop might be up to 3%, in accordance with the filters cleanliness. The maintenance periods strongly depend on the air quality variations at the filter house inlet in the zone where the power plant is located. [Espanol] El presente trabajo tiene por objetivo estudiar el efecto en la potencia generada en una turbina de gas de las condiciones de entrada del aire al compresor de una turbina de gas al pasar por un conjunto de filtros. Se presenta el algoritmo para la determinacion de las perdidas energeticas debidas a la variacion de la caida de presion generada por los filtros de acuerdo con su estado de limpieza. En la primera parte se ejemplifica el conjunto de variables que influyen en la eficiencia de las turbinas de gas, posteriormente se mencionan las caracteristicas de flujo de aire hacia una turbina y se muestran los efectos sobre el sistema. A continuacion se presentan los resultados obtenidos de la simulacion del sistema y se comparan con un caso real. De los resultados se puede apreciar que, dependiendo del sistema y de las condiciones ambientales el decremento en la eficiencia puede ser hasta del 3% en funcion del nivel de limpieza de los filtros. Los periodos de mantenimiento dependen fuertemente de las

  4. Positron Accumulator Ring (PAR) power supply

    International Nuclear Information System (INIS)

    Fathizadeh, M.

    1995-01-01

    The Positron Accumulator Ring (PAR) consists of 8 dipole magnets connected in series. These magnets are energized via one 12-pulse dc power supply. The power supply consists of four phase controlled half-wave wye group converters. Each of the two half-wave converters are connected through an interphase transformer to obtain a full-wave converter with 120 degrees conduction. The input voltage for these two half-wave converters are 180 degrees apart. The two full-wave converters are connected in parallel through a third interphase transformer. This type of connection of the converters not only provides the required output current, it also improves the input power factor of the power supply. The output of the wye group converters is filtered through a passive L-R-C filter to reduce the ripple content of the output current. At low current values of the power supply the current ripple is high, thus a large filter is needed, which adds to the cost of the power supply, however at high output current levels, the current ripple is less severe. The large size of the filter can be reduced by adding an anti-parallel rectifier diode(D1) to the output of the power supply. A freewheeling diode(D2) is connected before the choke to circulate the current once the power supply is turned off. In order to measure the current in the magnet a high precision, low drift, zero flux current transductor is used. This transductor senses the magnet current which provides a feedback signal to control the gating of the converter's thyristors. A true 14 bit Digital to Analog Converter (DAC) is programmed by the control computer for the required current value, providing a reference for the current regulator. Fast correction of the line transients is provided by a relatively fast voltage loop controlled by a high gain slow response current loop

  5. Voltage Harmonics Mitigation through Hybrid Active Power Filter

    Directory of Open Access Journals (Sweden)

    Anwer Ali Sahito

    2016-01-01

    Full Text Available Fast dynamic response, high efficiency, low cost and small size of power electronic converters have exponentially increased their use in modern power system which resulted in harmonically distorted voltage and currents. Voltage harmonics mainly caused by current harmonics are more dangerous as performance and expected operating life of other power system equipment are affected by harmonically distorted supply voltage. Electronic filter circuits are used to improve system power quality by mitigating adverse effects of harmonics. Hybrid filters having advantages of both passive and active filters are preferred to resolve the problem of harmonics efficiently and avoiding any chance of resonance. In this paper, a three phase three wire network is considered to supply an adjustable speed drive represented by a resistive load connected across a three phase bridge rectifier. Simulation of the considered system shows THD (Total Harmonic Distortion of 18.91 and 7.61% in supply current and voltage respectively. A HAPF (Hybrid Active Power Filter is proposed to reduce these THD values below 5% as recommended by IEEE Standard-519. P-Q theorem is used to calculate required parameters for proposed filter, which is implemented through hysteresis control. Simulation results confirm the effectiveness of the designed filter as THD for both current and voltage have reduced below allowable limit of 5%.

  6. Optimization in selection of the filter for central air conditioning system in public buildings%公共建筑集中空调系统过滤器选型方法优化

    Institute of Scientific and Technical Information of China (English)

    司鹏飞; 樊越胜; 李安桂; 谢伟; 龚锐; 戎向阳

    2011-01-01

    To meet the requirements of the average mass concentration of PM10 in indoor air and supply air, establishes a mathematical model for filter selection of the primary return air conditioning system according to the mass conservation law. In order to facilitate HVAC designing, simplifies the mathematical model, and gives the determination method of PM10 mass concentration in outdoor air and calculation methods of indoor dust production.%为了满足集中空调建筑室内PM10平均质量浓度以及送风气流中PM10的质量浓度要求,利用质量守恒定律建立了一次回风空调系统过滤器选型数学模型.为了便于暖通设计人员进行选型计算,对所建立的数学模型进行了合理的简化,并给出了室外PM10质量浓度的确定方法以及室内发尘量的计算方法.

  7. Biological treatment of wastewaters from a dye manufacturing company using a trickling filter

    International Nuclear Information System (INIS)

    Kornaros, M.; Lyberatos, G.

    2006-01-01

    The aim of this work was to assess the effectiveness of a biological trickling filter for the treatment of wastewaters produced by a company manufacturing organic dyes and varnishes. The combined wastewater effluent was fed to a pilot-scale trickling filter in two feeding modes, continuously and as a sequencing batch reactor (SBR). The biodegradability of the diluted wastewaters that were subjected to physicochemical treatment, using Ca(OH) 2 and FeSO 4 , was initially studied using a continuously operated trickling filter. The system efficiency ranged up to 60-70% for a hydraulic loading of 1.1 m 3 /m 2 day and up to 80-85% for a hydraulic loading 0.6 m 3 /m 2 day. A stable chemical oxygen demand (COD) removal efficiency of 60-70% was achieved even in the case of undiluted wastewater at a hydraulic loading of 1.1 m 3 /m 2 day. The effectiveness of biological treatment of a mixture of the company's main wastewater streams was also examined. The microorganisms developed in the trickling filter were able to efficiently remove COD levels up to 36,000 mg/L, under aerobic conditions at pH values between 5.5 and 8.0. Depending on the operating conditions of the system, about 30-60% of the total COD removal was attributed to air stripping caused by the air supply at the bottom of the filter, whereas the rest of the COD was clearly removed through biological action. The proposed biological treatment process based on a trickling filter, which was operated either continuously or even better in an SBR mode, appears as a promising pretreatment step for coping with dye manufacturing wastewaters in terms of removing a significant portion of the organic content

  8. Operability test procedure for 241-U compressed air system and heat pump

    International Nuclear Information System (INIS)

    Freeman, R.D.

    1994-01-01

    The 241-U-701 compressed air system supplies instrument quality compressed air to Tank Farm 241-U. The supply piping to the 241-U Tank Farm is not included in the modification. Modifications to the 241-U-701 compressed air system include installation of a 15 HP Reciprocating Air Compressor, Ingersoll-Rand Model 10T3NLM-E15; an air dryer, Hankinson, Model DH-45; and miscellaneous system equipment and piping (valves, filters, etc.) to meet the design. A newly installed heat pump allows the compressor to operate within an enclosed relatively dust free atmosphere and keeps the compressor room within a standard acceptable temperature range, which makes possible efficient compressor operation, reduces maintenance, and maximizes compressor operating life. This document is an Operability Test Procedure (OTP) which will further verify (in addition to the Acceptance Test Procedure) that the 241-U-701 compressed air system and heat pump operate within their intended design parameters. The activities defined in this OTP will be performed to ensure the performance of the new compressed air system will be adequate, reliable and efficient. Completion of this OTP and sign off of the OTP Acceptance of Test Results is necessary for turnover of the compressed air system from Engineering to Operations

  9. Air Quality and Health Impacts of an Aviation Biofuel Supply Chain Using Forest Residue in the Northwestern United States.

    Science.gov (United States)

    Ravi, Vikram; Gao, Allan H; Martinkus, Natalie B; Wolcott, Michael P; Lamb, Brian K

    2018-04-03

    Forest residue is a major potential feedstock for second-generation biofuel; however, little knowledge exists about the environmental impacts of the development and production of biofuel from such a feedstock. Using a high-resolution regional air quality model, we estimate the air quality impacts of a forest residue based aviation biofuel supply chain scenario in the Pacific Northwestern United States. Using two potential supply chain regions, we find that biomass and biofuel hauling activities will add simulation. Using BenMAP, a health impact assessment tool, we show that avoiding slash pile burning results in a decrease in premature mortality as well as several other nonfatal and minor health effects. In general, we show that most air quality and health benefits result primarily from avoided slash pile burning emissions.

  10. Filter for underground mining for suction of preferably full cut and part cut machines, to be provided with preheated air, to avoid dropping below the dew point

    Energy Technology Data Exchange (ETDEWEB)

    Hoelter, H.

    1976-10-28

    Particularly when cutting hard rock, the cutting room to be provided with suction is wetted with water from nozzles, which, when sucking out air containing dust with high humidity leads to encrustation in the filter cloth. In order to avoid this, it is proposed that the air should be heated, using heat from the motor driving the ventilator, so that one avoids dropping below the dew point in the filter.

  11. Series active power filter in power conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Turunen, J.

    2009-07-01

    Power quality has become an important issue nowadays for several reasons, e.g. modern society's growing dependence on electricity and the fact that poor power quality may generate significant economic losses in few moments. Probable power quality problems are, e.g. harmonics, flicker, voltage dips and supply interruptions. The power quality may be improved by using filters and compensators.The purpose of this thesis is to research the operation of the series active power filter (SAPF) in power conditioning. Therefore, this thesis presents a comparison of three series hybrid active power filters (SHAPFs) in current harmonics filtering. In addition to this, it is shown how the voltage dip compensation performance of the SAPF is improved in a unified power quality conditioner (UPQC) application.The three SHAPFs included in the comparison are series connected topology (SCT), filter connected topology (FCT) and electrically tuned LC shunt circuit (ETLC). The operating principle of these filters is to direct the harmonic currents produced by the load to flow in the LC shunt circuits instead of the supply. In the case of the SCT this phenomenon is boosted by applying so-called active resistance in the supply branch using the SAPF. In the case of the FCT a similar action is achieved by applying the compensation voltage in series with the LC shunt circuits using the SAPF. In the case of the ETLC the performance of the LC shunt circuit is enhanced by applying so-called active inductances in series with the LC shunt circuit using the SAPF. The SHAPFs are compared by searching for their best current filtering performance using various main circuit and control system configurations and loads. The operation of the SHAPFs is first analysed mathematically. After this, the current filtering performance of the SHAPFs is inspected using simulations and experimental tests. The experimental tests are carried out using SHAPF prototypes. As a result, it is shown that the current

  12. Effectiveness of interim stage filter in the exhaust system of glove boxes

    International Nuclear Information System (INIS)

    Patre, D.K.; Vangara, H.; Thanamani, S.; Gopalakrishnan, R.K.; Mhatre, Amol M.

    2018-01-01

    All operations in radiochemical laboratories are carried out in containment systems like Glove boxes and Fume hoods. For controlling air contamination two separate air cleaning systems are incorporated. Laboratory has general ventilation system and glove boxes are provided with a negative pressure system (NPS). Glove box exhaust air is passed through three stage filtration systems: in situ, interim and final before discharging to the atmosphere. In addition to the individual HEPA filters of each glove box, there is an interim HEPA filter bank introduced at the laboratory end. This was introduced to reduce a load on main exhaust filter system. Finally the exhaust air is discharged through the final stage HEPA filter located in the filter house through the Stack. The interim HEPA filter bank provides additional protection for the release of particulate activity and reduces load on the final stage filters. In the present work efforts have been put to validate the interim stage filter, which has been introduced, to limit the environmental release

  13. Filter case for separating out radioactive effluents from gas flows

    International Nuclear Information System (INIS)

    Jannakos, K.; Zabel, G.

    1982-01-01

    A remotely operated change of filter in a filter case can be done with an annular or cylindrical filter insert, where the contaminated air side remains separate from the clean air side. A lid is provided which can be divided into two parts, and by which the openings of the filter insert and also in the intermediate floor can be opened or closed using the double lid technique. When closing the filter case lid, the double lid closure is always opened. (DG) [de

  14. Removal of residual particulate matter from filter media

    Science.gov (United States)

    Almlie, Jay C; Miller, Stanley J

    2014-11-11

    A method for removing residual filter cakes that remain adhered to a filter after typical particulate removal methodologies have been employed, such as pulse-jet filter element cleaning, for all cleanable filters used for air pollution control, dust control, or powder control.

  15. Removal of residual particulate matter from filter media

    Energy Technology Data Exchange (ETDEWEB)

    Almlie, Jay C.; Miller, Stanley J.

    2018-01-09

    A method for removing residual filter cakes that remain adhered to a filter after typical particulate removal methodologies have been employed, such as pulse-jet filter element cleaning, for all cleanable filters used for air pollution control, dust control, or powder control.

  16. The Air Force Mobile Forward Surgical Team (MFST): Using the Estimating Supplies Program to Validate Clinical Requirement

    National Research Council Canada - National Science Library

    Nix, Ralph E; Onofrio, Kathleen; Konoske, Paula J; Galarneau, Mike R; Hill, Martin

    2004-01-01

    .... The primary objective of the study was to provide the Air Force with the ability to validate clinical requirements of the MFST assemblage, with the goal of using NHRC's Estimating Supplies Program (ESP...

  17. Air Filtration as Protection against Fouling of Ventilation and Air Conditioning Units

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Lajčíková, Ariana

    2005-01-01

    Currently, air filters are one of the most critical components of air treatment systems as they decontaminate the air delivered to living space. During the operation, however, the level of harmful surface deposits increases, and at certain times, an uncleaned filter can itself become a source...... of undesirable contaminents influencing negatively the IAQ of a living space. This is the phenomenon that has been a subject of the current research. The article presents a new, alternative view on indoor air contaminents and filtration requirements. It describes alternative means of filtration and assesses...... issues of inadequate maintenance and/or long term use of applied air filters. An experimental method of evealuating the air quality by means of chemical analysis and state-of-the-art spectrometer is also described....

  18. Reduced energy reqirement for air conditioning by using air diffusion with air flow from floor to ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Dittes, W; Mangelsdorf, R; Detzer, R; Jungbaeck, E; Fitzner, K; Radtke, W; Soethout, F

    1982-02-01

    The condition of the air in the occupied zone in airconditioned rooms is influenced by the mixing of supply air with room air. When supplying air from the ceiling there is a mixing all over the room, when supplying from the floor or from desks there is a mixing region only in the lower area. Above this their is warm air from which the return air is drawn. For air supply from below the cooling load can be decreased. In combination with the possible enthalpy difference between room air and supply air this decrease of the cooling load influences the necessary air rate. The interdependence of various air conditioning systems and various air temperatures is shown with a computer program. The load factor for various air distribution system at various cooling loads have been measured in a room of (8 x 5)m/sup 2/ x 3m. Experiments in a smaller model room (scale 1:3) showed how the heat was transported from the mixing region to the stratification region. The theoretically gained influence of the supply air jets of the height of the mixing region and on the load rate could be verified by the experiments. For the design of the fresh air rate, experience has been gained by measurements with tracegas (N/sub 2/O) in a third room. In comparing calculations the annual energy consumption has been computed for a building assuming various air conditioning systems and typical operation data. From experience with the existing systems the conclusions have been drawn how air distribution from floor to ceiling can be installed and operated.

  19. Development of a method for bacteria and virus recovery from heating, ventilation, and air conditioning (HVAC) filters.

    Science.gov (United States)

    Farnsworth, James E; Goyal, Sagar M; Kim, Seung Won; Kuehn, Thomas H; Raynor, Peter C; Ramakrishnan, M A; Anantharaman, Senthilvelan; Tang, Weihua

    2006-10-01

    The aim of the work presented here is to study the effectiveness of building air handling units (AHUs) in serving as high volume sampling devices for airborne bacteria and viruses. An HVAC test facility constructed according to ASHRAE Standard 52.2-1999 was used for the controlled loading of HVAC filter media with aerosolized bacteria and virus. Nonpathogenic Bacillus subtilis var. niger was chosen as a surrogate for Bacillus anthracis. Three animal viruses; transmissible gastroenteritis virus (TGEV), avian pneumovirus (APV), and fowlpox virus were chosen as surrogates for three human viruses; SARS coronavirus, respiratory syncytial virus, and smallpox virus; respectively. These bacteria and viruses were nebulized in separate tests and injected into the test duct of the test facility upstream of a MERV 14 filter. SKC Biosamplers upstream and downstream of the test filter served as reference samplers. The collection efficiency of the filter media was calculated to be 96.5 +/- 1.5% for B. subtilis, however no collection efficiency was measured for the viruses as no live virus was ever recovered from the downstream samplers. Filter samples were cut from the test filter and eluted by hand-shaking. An extraction efficiency of 105 +/- 19% was calculated for B. subtilis. The viruses were extracted at much lower efficiencies (0.7-20%). Our results indicate that the airborne concentration of spore-forming bacteria in building AHUs may be determined by analyzing the material collected on HVAC filter media, however culture-based analytical techniques are impractical for virus recovery. Molecular-based identification techniques such as PCR could be used.

  20. Diesel engine exhaust particulate filter with intake throttling incineration control

    Energy Technology Data Exchange (ETDEWEB)

    Ludecke, O.; Rosebrock, T.

    1980-07-08

    A description is given of a diesel engine exhaust filter and particulate incineration system in combination with a diesel engine having a normally unthrottled air induction system for admitting combustion air to the engine and an exhaust system for carrying off spent combustion products exhausted from the engine, said filter and incineration system comprising: a combustion resistant filter disposed in the exhaust system and operative to collect and retain portions of the largely carbonaceous particulate matter contained in the engine exhaust products, said fiber being capable of withstanding without substantial damage internal temperatures sufficient to burn the collected particulate matter, a throttle in the indication system and operable to restrict air flow into the engine to reduce the admittance of excess combustion air and thereby increase engine exhaust gas temperature, and means to actuate said throttle periodically during engine operation to an air flow restricting burn mode capable of raising the particulates in said filter to their combustion temperature under certain engine operating conditions and to maintain said throttle mode for an interval adequate to burn retained particulates in the filter.

  1. Balance of the air pollution reduction effect of new technologies in East Germany

    International Nuclear Information System (INIS)

    Kampet, T.; Broege, M.; Jappe, H.; Jones, E.; Koerner, T.; Lindner, H.

    1992-01-01

    Between 1989 and 2010, the energy supply in the new Federal States of Germany must undergo a reduction of environmental pollution. This is possible by changing of energy sources (e.g. reduction of using of brown coal), reduction of energy losses, reduction of emissions by improvements in the quality of fuel and by technical improvements for keeping air clean (e.g. dust filters). (VT)

  2. Elemental analysis of dust trapped in air conditioner filters for the assessment of Lahore city's air quality

    International Nuclear Information System (INIS)

    Siddique, N.

    2011-01-01

    A study was undertaken to assess the air quality of Lahore by the elemental analysis of air conditioner (AC) filter dust samples collected from 15 different commercial sites. Samples were prepared using the Leeds Public Analyst Method and were analyzed using instrumental neutron activation analysis (INAA) for up to 31 elements. The elements Al, As, Ba, Ce, Co, Cr, Cs, Fe, Hf, K, La, Lu, Mn, Na, Nd, Rb, Sc, Sm, Sn, Ta, Th, Yb and Zn were detected in all 15 samples whereas the remaining elements have been detected in fewer samples; i.e. Mg, Sb and Tb were detected in 14 samples, Br and V in ten samples, U in nine samples and Ca and Ti in eight samples only. Al, Ca, Fe, K, Mg and Na were determined in all samples at percentage levels. The concentrations of most elements were found to lie around the mean values for the 15 samples studied and were not orders of magnitude different. However the concentrations of Ca, Mg, Sn and Zn were found to be more variable and were found to be dependant on activities such as construction, fruit and vegetable handling, tin plating and transport, respectively. (author)

  3. PM10 sampler deposited air particulates: Ascertaining uniformity of sample on filter through rotated exposure to radiation

    International Nuclear Information System (INIS)

    Owoade, Oyediran K.; Olise, Felix S.; Obioh, Imoh B.; Olaniyi, Hezekiah B.; Bolzacchini, Ezio; Ferrero, Luca; Perrone, Grazia

    2006-01-01

    For reproducibility of analytical results of samples deposited on filters using PM 10 sampler, homogeneity of the sample on the filter is very important especially when the size of the X-ray beam for the analysis is less than the size of filter. It is against this background that the air particulate samples collected on using PM 10 samplers are analysed to determine the elemental concentrations. Each sample was divided into four quadrants and each was analysed under same conditions to determine if the particles were deposited uniformly over the filter. Each analysis was done using EDXRF technique. The spectrometer consists of four secondary targets, which are automatically switched to in sequence in analysing each sample. The concentration of various elements detected was determined using TURBOQUANT (a brand name for a SPECTRO method which is used for screening analysis). Sixteen elements were detected in every sample. Results show that there was less than 10% deviation in the concentrations in different quadrants. There were a few elements like Ba, Cs, etc., which have deviation greater than 20%. The concentrations of these latter elements were close to detection limits of the spectrometer. We conclude that the analytical result of particulate samples deposited on filters by the PM 10 sampler can be reliable in terms of the homogeneity of the deposition. For such analytes with low concentrations, it would be important that the sampling time be increased to allow for higher mass deposition on the filter

  4. HEPA filter concerns - an overview

    Energy Technology Data Exchange (ETDEWEB)

    Leonard, J.F. [Department of Energy, Washington, DC (United States)

    1995-02-01

    The U.S. Department of Energy (DOE) recently initiated a complete review of the DOE High Efficiency Particulate Air (HEPA) Filter Program to identify areas for improvement. Although this process is currently ongoing, various issues and problems have already been identified for action that not only impacts the DOE HEPA filter program, but potentially the national and international air cleaning community as well. This paper briefly reviews a few of those concerns that may be of interest, and discusses actions initiated by the DOE to address the associated issues and problems. Issues discussed include: guidance standards, in-place testing, specifications, Test Facilities, portable units, vacuum cleaners, substitute aerosols, filter efficiencies, aging/shelf life/service life, fire suppression, handbook, Quality Products List (QPL), QA testing, and evaluations.

  5. Air filtration and air cooling in dairies

    Energy Technology Data Exchange (ETDEWEB)

    Rubzov, J A

    1986-01-01

    In addition to the maintenance of optimum temperatures and relative humidities, a continuous cleaning of the circulating air by means of suspended matter filters and regular disinfection of the spaces and equipment are required in the maturing and storage room for cheese. This contribution presents solutions to the use of suspended matter filters in air cooling plant for dairies in the U.S.S.R.

  6. Effects of reducing exposure to air pollution on submaximal cardiopulmonary test in patients with heart failure: Analysis of the randomized, double-blind and controlled FILTER-HF trial.

    Science.gov (United States)

    Vieira, Jefferson L; Guimaraes, Guilherme V; de Andre, Paulo A; Saldiva, Paulo H Nascimento; Bocchi, Edimar A

    2016-07-15

    Air pollution exposure could mitigate the health benefits of exercise in patients with heart failure (HF). We tested the effects of a respiratory filter on HF patients exposed to air pollution during exercise. Ancillary analysis of the FILTER-HF trial, focused on the exercise outcomes. In a randomized, double-blind, 3-way crossover design, 26 HF patients and 15 control volunteers were exposed to clean air, unfiltered dilute diesel engine exhaust (DE), or filtered DE for 6min during a submaximal cardiopulmonary testing in a controlled-exposure facility. Prospectively collected data included six-minute walking test [6mwt], VO2, VE/VCO2 Slope, O2Pulse, pulmonary ventilation [VE], tidal volume, VD/Vt, oxyhemoglobin saturation and CO2-rebreathing. Compared to clean air, DE adversely affected VO2 (11.0±3.9 vs. 8.4±2.8ml/kg/min; preduced the particulate concentration from 325±31 to 25±6μg/m(3), and was associated with an increase in VO2 (10.4±3.8ml/kg/min; preduce the adverse effects of pollution on VO2 and O2Pulse. Given the worldwide prevalence of exposure to traffic-related air pollution, these findings are relevant for public health especially in this highly susceptible population. The filter intervention holds great promise that needs to be tested in future studies. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Passenger evaluation of the optimum balance between fresh air supply and humidity from 7-h exposures in a simulated aircraft cabin

    DEFF Research Database (Denmark)

    Strøm-Tejsen, Peter; Wyon, David Peter; Lagercrantz, Love Per

    2007-01-01

    A 21-seat section of an aircraft cabin with realistic pollution sources was built inside a climate chamber capable of providing fresh outside air at very low humidity. Maintaining a constant 200 l/s rate of total air supply, i.e. recircu-lated and make-up air, to the cabin, experiments simulating 7...

  8. A bag adapted for the handling of a filtering element or filter unit

    International Nuclear Information System (INIS)

    Marshall, D.A.G.

    1980-01-01

    The invention relates to a transparent, flexible, synthetic plastics bag adapted to contain a filter element or filter unit so that the latter can be inserted into or removed from a filter casing or duct while being contained in the bag. The bag has a neck portion which is capable of being removably secured in an air-tight manner on to a part of the casing, and gloves or glove portions are provided in, or are formed in, the wall of the bag to permit handles on the filter element or unit to be grasped. (author)

  9. Low pressure chemical vapour deposition of temperature resistant colour filters

    International Nuclear Information System (INIS)

    Verheijen, J.; Bongaerts, P.; Verspui, G.

    1987-01-01

    The possibility to deposit multilayer colour filters, based on optical inference, by means of Low Pressure Chemical Vapour Deposition (LPCVD) was investigated. The filters were made in a standard LPCVD system by alternate deposition of Si/sub 3/N/sub 4/ and SiO/sub 2/ layers. This resulted in filters with excellent colour uniformity on glass and quartz substrates. No difference was measured between theoretically calculated transmission and the transmission of the filters deposited by LPCVD. Temperature treatment at 600 0 C in air air showed no deterioration of filter quality and optical properties

  10. Proposed retrofit of HEPA filter plenums with injection and sampling manifolds for in-place filter testing

    Energy Technology Data Exchange (ETDEWEB)

    Fretthold, J.K. [EG& G Rocky Flats, Inc., Golden, CO (United States)

    1995-02-01

    The importance of testing HEPA filter exhaust plenums with consideration for As Low as Reasonably Achievable (ALARA) will require that new technology be applied to existing plenum designs. HEPA filter testing at Rocky Flats has evolved slowly due to a number of reasons. The first plenums were built in the 1950`s, preceding many standards. The plenums were large, which caused air dispersal problems. The systems were variable air flow. Access to the filters was difficult. The test methods became extremely conservative. Changes in methods were difficult to make. The acceptance of new test methods has been made in recent years with the change in plant mission and the emphasis on worker safety.

  11. Qualitative analysis by X ray fluorescence of impurities in materials used as air filters; Analisis cualitativo por fluorescencia de rayos X de impurezas en materiales utilizados como filtros de aire

    Energy Technology Data Exchange (ETDEWEB)

    Lartigue G, J; Munoz M, G; Navarrete T, M [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    1995-06-01

    A qualitative analysis of impurities in 5 materials commonly used as air filters was performed with 2 aims: to compare them, in regard to their impurities and to set a methodology to identify spectroscopically, in a short time (1000 seconds), those impurities in order to subtract the blanks signal from that one generated by the collected sample. Some papers on air filters impurities (cellulose, polycarbonate and glass fiber) were found in literature. In one case, the analysis was performed by energy-dispersive X ray fluorescence, tube generated method. In this work it was employed the same method but a radioisotope (Cd-109) was used as primary source. This was applied to 2 of the above mentioned materials as well as to nylon, teflon and quartz. The glass fiber filter had the highest impurity level: Ca, Ba, Pb, Zn, Sr, Rb, and Fe (0.5 {mu}gFe/cm{sup 2}, measured by Atomic Absorption Spectroscopy). The teflon filter had the lowest impurity level. The developed procedure is fast, precise and reproducible and it may be applied also to wastewaters filters. [Spanish] Se realizo el analisis cualitativo de impurezas en cinco materiales comunmente utilizados como filtros de aire, con dos propositos: compararlos en base a sus impurezas y establecer una metodologia que permitiera, en muy corto tiempo (1000 segundos), identificar espectroscopicamente las impurezas a fin de restar la senal del blanco de aquella que genera eventualmente la muestra. En la bibliografia se encontraron algunas publicaciones acerca de impurezas en filtros de aire (celulosa, pollicarbonato y fibra de vidrio), determinadas principalmente por Absorcion Atomica. En un caso, tal determinacion se realizo por Fluorescencia de Rayos X generados en tubo de descargas y detectados por dispersion de energia. En este trabajo se empleo el mismo metodo de Fluorescencia de Rayos X detectados por dispersion de energia pero generados por un radioisotopo (Cd-109) y se aplico a dos de los tres materiales antes

  12. Pollution by air filters: Continuous vs intermittent air flow

    NARCIS (Netherlands)

    Cox, C.W.J.; Bluyssen, P.M.

    2000-01-01

    Within the framework of the EU research project Airless, a long-term experiment of 28 weeks was carried out to investigate the influence of intermittent airflow compared to continuous airflow on the pollution effect of glass fibre filters (F7). No statistical relevant differences between odour

  13. Switched Current Micropower 4th Order Lowpass / Highpass Filter

    DEFF Research Database (Denmark)

    Bogason, Gudmundur

    1993-01-01

    This paper describes a 4th order lowpass / highpass Butterworth filter implemented in switched current technique. The filter has been designed for low power operation. A prototype implementation has been made and it operates with supply voltages down to 2V and with a total supply current of 211Â......¿A at a sampling rate of 50kHz. The chip includes a clock-generator, three current-followers, sample-and-hold and two 4th order filters. The sampling frequency is restricted to approximately 50kHz and the ratio between sampling frequency and cutoff frequency is 12.5. The dynamic-range was found to be 49d...

  14. Development of circular filters for active facilities

    International Nuclear Information System (INIS)

    Pratt, R.P.

    1986-01-01

    An assessment of problems associated with remote handling, changing and disposal of filters suggested that significant improvements to filtration systems could be made if circular geometries were adopted in place of conventional systems. Improved systems have been developed and are now available for a range of applications and air flow rates. Where primary filters are installed within the active cell or cave, circular filters incorporating a lip seal have been developed which enable the filters to be sealed into the facility without recourse to clamping. For smaller cells, a range of push-through filter change systems have been developed, the principal feature being that the filter is passed into the housing from the clean side, but transferred from the housing directly into the cell for subsequent disposal. For plant room applications, circular bag change canister systems have been developed which ease the sealing and bag change operation. Such systems have a rated air flow of up to 3000 m 3 /h whilst still allowing ultimate disposal via the 200 litre waste drum route without prior volume reduction of the filter inserts. (author)

  15. The real-time gas mass filter system for the analysis of products from trichloroethylene-air mixture during electron beam irradiation

    International Nuclear Information System (INIS)

    Hakoda, Teruyuki; Arai, Hidehiko; Hashimoto, Shoji

    2001-01-01

    The real-time gas mass filter system consisting of a mass filter and a capillary sampling tube was developed for the analysis of products during electron beam (EB) irradiation of trichloroethylene (TCE)-air mixture. Interesting trace substances in gases are analyzed by this gas mass filter system in real time. The gases at atmospheric pressure are introduced to the mass filter under vacuum through a capillary tube without packing. The system was calibrated with three different standard mono-gases which contain known concentrations of sulfur dioxide, benzene and chlorobenzene for each. And its detectable limits for each gas were in the range of 0.7-1 ppmv. Products of irradiated TCE-air mixture were analyzed with the system in real time. The concentrations of dichloroacetyl chloride and carbonyl chloride (COCl 2 ) increased by low dose irradiation when TCE was decomposed. These products decreased by higher dose irradiation and were identified as primary products. Trichloroethylene and these primary products were oxidized into CO 2 , Cl 2 , and HCl at 15 kGy. Carbonyl chloride was dissolved in NaOH aq for natural-oxidation into CO 3 2- and Cl - . The doses for the complete oxidation of TCE and the products were decreased from 15 to 7 kGy by the combination of the irradiation and the dissolution of the irradiated gas. The decomposition mechanism of TCE, especially formation of COCl 2 , was clarified from the change of the products as a function of dose. (author)

  16. Determination of tricresyl phosphate air contamination in aircraft.

    Science.gov (United States)

    Denola, G; Hanhela, P J; Mazurek, W

    2011-08-01

    Monitoring of tricresyl phosphate (TCP) contamination of cockpit air was undertaken in three types of military aircraft [fighter trainer (FT), fighter bomber (FB), and cargo transport (CT) aircraft]. The aircraft had a previous history of pilot complaints about cockpit air contamination suspected to originate from the engine bleed air supply through the entry of aircraft turbine engine oil (ATO) into the engine compressor. Air samples were collected in flight and on the ground during engine runs using sorbent tubes packed with Porapak Q and cellulose filters. A total of 78 air samples were analysed, from 46 different aircraft, and 48 samples were found to be below the limit of detection. Nine incidents of smoke/odour were identified during the study. The concentrations of toxic o-cresyl phosphate isomers were below the level of detection in all samples. The highest total TCP concentration was 51.3 μg m(-3), while most were generally found to be contamination of cabin/cockpit air has been the subject of much concern in aviation, quantitative data are sparse.

  17. Human Response to Ductless Personalized Ventilation with Local Air Cleaning: Air Quality and Prevalence of SBS Symptoms

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Bivolarova, Maria; Fillon, Maelys

    2013-01-01

    The impact of local air cleaning and cooling of the head region by ductless personalized ventilation (DPV) on perceived air quality (PAQ) and Sick Building Syndrome (SBS) symptoms was studied. Thirty subjects participated in experiments performed in a test room with displacement ventilation (DV...... with air filter and 29 °C with DPV without filter. During the experiments the subjects simulated office work and answered on computerized questionnaires. At warm environment PAQ and air freshness significantly improved when DPV was used. Eye dryness increased significantly with time but was not influenced...... by air temperature and filtering. At 29 °C the facially applied air movement from DPV increased the eye dryness. The SBS symptoms increased with time and were higher (not significantly) at the warm conditions. Air movement did not have profound impact on the SBS symptoms, while filtering had only at 23...

  18. Chemical Characterization of the Indoor Air Quality of a University Hospital: Penetration of Outdoor Air Pollutants

    Directory of Open Access Journals (Sweden)

    Paul T. J. Scheepers

    2017-05-01

    Full Text Available For healthcare centers, local outdoor sources of air pollution represent a potential threat to indoor air quality (IAQ. The aim of this study was to study the impact of local outdoor sources of air pollution on the IAQ of a university hospital. IAQ was characterized at thirteen indoor and two outdoor locations and source samples were collected from a helicopter and an emergency power supply. Volatile organic compounds (VOC, acrolein, formaldehyde, nitrogen dioxide (NO2, respirable particulate matter (PM-4.0 and PM-2.5 and their respective benz(apyrene contents were determined over a period of two weeks. Time-weighted average concentrations of NO2 (4.9–17.4 μg/m3 and formaldehyde (2.5–6.4 μg/m3 were similar on all indoor and outdoor locations. The median concentration VOC in indoor air was 119 μg/m3 (range: 33.1–2450 μg/m3 and was fivefold higher in laboratories (316 μg/m3 compared to offices (57.0 μg/m3. PM-4.0 and benzo(apyrene concentration were lower in buildings serviced by a >99.95% efficiency particle filter, compared to buildings using a standard 80–90% efficiency filter (p < 0.01. No indications were found that support a significant contribution of known local sources such as fuels or combustion engines to any of the IAQ parameters measured in this study. Chemical IAQ was primarily driven by known indoor sources and activities.

  19. Unit for air decontamination; Unidad para descontaminacion de aire

    Energy Technology Data Exchange (ETDEWEB)

    Mariano H, E

    1991-02-15

    To fulfill the applicable requirements of safety to the ventilation systems in nuclear facilities, it is necessary to make a cleaning of the air that hurtles to the atmosphere. For that which was designed and it manufactured an unit for decontamination of the air for the Pilot plant of production of Nuclear Fuel that this built one with national parts, uses Hepa national filters and the design can adapt for different dimensions of filters, also can be added a lodging for a prefilter or to adopt two Hepa filters. (Author)

  20. Report on the quality control study NAT-7 for the determination of trace and minor elements in dust artificially loaded on air filters

    International Nuclear Information System (INIS)

    Bleise, A.; Smodis, A.

    2002-02-01

    A quality control study was organized on two air filters artificially loaded with urban dust. One dust material was collected from the air intake ducts of the Vienna General Hospital, the second material was collected from the main ventilation shaft of a road tunnel in Prague. 49 laboratories from 40 countries participated in the study, providing 53 sets of results. The following analytical methods were used: neutron activation analysis (NAA), inductive coupled plasma atomic emission spectrometry (ICP-AES), inductively coupled plasma mass spectrometry (ICP-MS), particle induced X-ray emission spectrometry (PDCE), atomic absorption spectrometry (AAS), and X-ray fluorescence spectrometry (XRF). The results were evaluated following the standard LEA procedures for (1) an interlaboratory comparison exercise and (2) a proficiency test using established target values. For the air filter sample V, 754 laboratory mean values for 38 elements were reported. More than 4 mean values were obtained for 26 measurands and these were statistically evaluated. Only 10 % 71 values) of the results were detected as outliers by the statistical data evaluation. The results and statistical parameters are listed in the appendices I and II. The results were also evaluated as a proficiency test using established target values. Precision and accuracy criteria were applied to 15 elements. 534 laboratory mean values were reported for those elements, 114 values (20%) did not pass the set proficiency test criteria. The individual laboratory results are listed in appendix IV. For the air filter sample P, 694 laboratory mean values for 38 elements were reported. More than 4 mean values were obtained for 26 measurands and these were statistically evaluated. Only 9% (60 values) of the results were detected as outliers by the statistical data evaluation. The results and statistical parameters are listed in the appendices I and II. The results were also evaluated as a proficiency test using target values

  1. Field evaluation of prototype electrofibrous filters

    International Nuclear Information System (INIS)

    Kuhl, W.D.; Bergman, W.; Biermann, A.H.; Lum, B.Y.

    1982-01-01

    New prototype electrofibrous filters were designed, built and evaluated in laboratory tests and in field installations. Two prototypes were designed for use in nuclear ventilation ducts as prefilters to HEPA filters. One prototype is designed to be a permanent component of the ventilation system while the other is a disposable unit. The disposable electrofibrous prefilter was installed in the exhaust stream of a glove box in which barrels of uranium turnings are burned. Preliminary tests show the disposal prefilter is effectively prolonging the HEPA filter life. An earlier prototype of the rolling prefilter was upgraded to meet the increased requirements for installation in a nuclear facility. This upgraded prototype was evaluated in the fire test facility at LLNL and shown to be effective in protecting HEPA filters from plugging under the most severe smoke conditions. The last prototype described in this report is a recirculating air filter. After demonstrating a high performance in laboratory tests the unit was shipped to Savannah River where it is awaiting installation in a Pu fuel fabrication facility. An analysis of the particulate problem in Savannah River indicates that four recirculating air filter will save $172,000 per year in maintenance costs

  2. Air pollution and health impact emboided in supply chains in China

    Science.gov (United States)

    Zhang, Q.

    2016-12-01

    Close economic linkage and consequent air pollutant emissions embodied in trade among Chinese regions have been widely discussed. Yet the related health impacts across regions remain unaddressed. Here, we integrated four state-of-the-art models to for the first time estimate PM2.5 related premature deaths along the supply chains across seven Chinese regions, and we quantified cross impacts among receptors, producers, assemblers, consumers, and sectors. We find that, due to the atmospheric transport, in 2010, 33% of national premature deaths were caused by emissions released in other regions, and the trans-boundary effect is more significant from north to south and from east to west. From a supply chain perspective, 38% of national premature deaths were associated with production for in a region to supply other regions' consumption. For instance, 20-35% of premature deaths related to the highly developed east coastal regions' consumption were caused by emissions in the central and western regions. Sectorally, similar to the widely concerned heavy industries, direct emissions from agricultural and residential activities together contributed near half of national total premature deaths, posing a great challenge for recent pollution reduction action, which are mainly focusing on industrial restructuring. Our results emphasize the importance of regarding pollution related premature deaths in China as a national systemic problem, instead of targeting the pollution producers (region or sector) in isolation. Multilateral and multi-sector cooperation is in urgent need to improve the national atmospheric environment.

  3. Potential for HEPA filter damage from water spray systems in filter plenums

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W. [Lawrence Livermore National Lab., CA (United States); Fretthold, J.K. [Rocky Flats Safe Sites of Colorado, Golden, CO (United States); Slawski, J.W. [Department of Energy, Germantown, MD (United States)

    1997-08-01

    The water spray systems in high efficiency particulate air (HEPA) filter plenums that are used in nearly all Department of Energy (DOE) facilities for protection against fire was designed under the assumption that the HEPA filters would not be damaged by the water sprays. The most likely scenario for filter damage involves filter plugging by the water spray, followed by the fan blowing out the filter medium. A number of controlled laboratory tests that were previously conducted in the late 1980s are reviewed in this paper to provide a technical basis for the potential HEPA filter damage by the water spray system in HEPA filter plenums. In addition to the laboratory tests, the scenario for BEPA filter damage during fires has also occurred in the field. A fire in a four-stage, BEPA filter plenum at Rocky Flats in 1980 caused the first three stages of BEPA filters to blow out of their housing and the fourth stage to severely bow. Details of this recently declassified fire are presented in this paper. Although these previous findings suggest serious potential problems exist with the current water spray system in filter plenums, additional studies are required to confirm unequivocally that DOE`s critical facilities are at risk. 22 refs., 15 figs.

  4. PM{sub 10} sampler deposited air particulates: Ascertaining uniformity of sample on filter through rotated exposure to radiation

    Energy Technology Data Exchange (ETDEWEB)

    Owoade, Oyediran K. [Environmental Research Laboratory (ERL), Physics Department, Obafemi Awolowo University, Ile-Ife (Nigeria)]. E-mail: oowoade2001@yahoo.com; Olise, Felix S. [Environmental Research Laboratory (ERL), Physics Department, Obafemi Awolowo University, Ile-Ife (Nigeria); Obioh, Imoh B. [Centre for Energy Research, Development (Cerd), Obafemi Awolowo University, Ile-Ife (Nigeria); Olaniyi, Hezekiah B. [Environmental Research Laboratory (ERL), Physics Department, Obafemi Awolowo University, Ile-Ife (Nigeria); Bolzacchini, Ezio [Universita Milano-Bicocca, Dipartimento di Scienze-Ambientali, Pizza della Scienza, Milan (Italy); Ferrero, Luca [Universita Milano-Bicocca, Dipartimento di Scienze-Ambientali, Pizza della Scienza, Milan (Italy); Perrone, Grazia [Universita Milano-Bicocca, Dipartimento di Scienze-Ambientali, Pizza della Scienza, Milan (Italy)

    2006-08-01

    For reproducibility of analytical results of samples deposited on filters using PM{sub 10} sampler, homogeneity of the sample on the filter is very important especially when the size of the X-ray beam for the analysis is less than the size of filter. It is against this background that the air particulate samples collected on using PM{sub 10} samplers are analysed to determine the elemental concentrations. Each sample was divided into four quadrants and each was analysed under same conditions to determine if the particles were deposited uniformly over the filter. Each analysis was done using EDXRF technique. The spectrometer consists of four secondary targets, which are automatically switched to in sequence in analysing each sample. The concentration of various elements detected was determined using TURBOQUANT (a brand name for a SPECTRO method which is used for screening analysis). Sixteen elements were detected in every sample. Results show that there was less than 10% deviation in the concentrations in different quadrants. There were a few elements like Ba, Cs, etc., which have deviation greater than 20%. The concentrations of these latter elements were close to detection limits of the spectrometer. We conclude that the analytical result of particulate samples deposited on filters by the PM{sub 10} sampler can be reliable in terms of the homogeneity of the deposition. For such analytes with low concentrations, it would be important that the sampling time be increased to allow for higher mass deposition on the filter.

  5. Field test of radioactive high efficiency filter and filter exchange techniques of fuel cycle examination facility

    International Nuclear Information System (INIS)

    Hwang, Yong Hwa; Lee, Hyung Kwon; Chun, Young Bum; Park, Dae Gyu; Ahn, Sang Bok; Chu, Yong Sun; Kim, Eun Ka.

    1997-12-01

    The development of high efficiency filter was started to protect human beings from the contamination of radioactive particles, toxic gases and bacillus, and its gradual performance increment led to the fabrication of Ultra Low Penetration Air Filter (ULPA) today. The application field of ULPA has been spread not only to the air conditioning of nuclear power facilities, semiconductor industries, life science, optics, medical care and general facilities but also to the core of ultra-precision facilities. Periodic performance test on the filters is essential to extend its life-time through effective maintenance. Especially, the bank test on HEPA filter of nuclear facilities handling radioactive materials is required for environmental safety. Nowadays, the bank test technology has been reached to the utilization of a minimized portable detecting instruments and the evaluation techniques can provide high confidence in the area of particle distribution and leakage test efficiency. (author). 16 refs., 13 tabs., 14 figs

  6. Coagulation, flocculation, dissolved air flotation and filtration in the removal of Giardia spp. and Cryptosporidium spp. from water supply.

    Science.gov (United States)

    Andreoli, Fernando César; Sabogal-Paz, Lyda Patricia

    2017-11-15

    Removing protozoa from a water supply using coagulation, flocculation, dissolved air flotation (DAF) and filtration on a bench scale was evaluated. Calcium carbonate flocculation with and without immunomagnetic separation (IMS) was chosen to detect Giardia spp. cysts and Cryptosporidium spp. oocysts in the studied samples. The results indicated that DAF removed between 1.31 log and 1.79 log of cysts and between 1.08 log and 1.42 log of oocysts. The performance was lower in filtration, with the removal of 1.07 log-1.44 log for cysts and 0.82 log-0.98 log for oocysts. The coagulation, flocculation, DAF and filtration steps removed more than 2.2 log of cysts and oocysts from the water studied. However, protozoa were detected in the filtered water, even with turbidity values of 0.2 NTU. The recovery of the detection method met the international criteria and was higher when there was no IMS. Including the third acid dissociation in the IMS was critical to improve the performance of the protocol tested. However, there was an increase in the technical and analytical complexity and costs. It was also observed that the efficiency of the treatment was linked to the performance of the selected method of detecting protozoa.

  7. Preliminary studies to determine the shelf life of HEPA filters

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, H.; Fretthold, J.K.; Rainer, F. [Lawrence Livermore National Laboratory, CA (United States)] [and others

    1995-02-01

    We have completed a preliminary study using filter media tests and filter qualification tests to investigate the effect of shelf-life on HEPA filter performance. Our media studies showed that the tensile strength decreased with age, but the data were not sufficient to establish a shelf-life. Thermogravimetric analyses demonstrated that one manufacturer had media with low tensile strength due to insufficient binder. The filter qualification tests (heated air and overpressure) conducted on different aged filters showed that filter age is not the primary factor affecting filter performance; materials and the construction design have a greater effect. An unexpected finding of our study was that sub-standard HEPA filters have been installed in DOE facilities despite existing regulations and filter qualification tests. We found that the filter with low tensile strength failed the overpressure test. The same filter had passed the heated air test, but left the filter so structurally weak, it was prone to blow-out. We recommend that DOE initiate a filter qualification program to prevent this occurrence.

  8. Underground coal mine air quality in mines using disposable diesel exhaust filter control devices

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, D.H.; Johnson, J.H.; Bagley, S.T.; Gratz, L.D. [Michigan Technological University, Houghton, MI (United States). Dept. of Mining Engineering

    1996-07-01

    As part of a collaborative study with the US Bureau of Mines, in-mine studies have been conducted to assess the effects of a low temperature disposable diesel exhaust filter. The mines have been designed as mines R and S in US Bureau of Mines publications. Each mine operated three to four Jeffrey 4110 ramcar haulage vehicles in the test section. The ramcars were equipped with MWM D916-6 diesel engines, rated at 74.6 kW (100 hp), and were operated for 3 days with the disposal diesel exhaust filter and 2 days without in both mines. Average diesel particulate matter control efficiencies, as measured by samplers located on the coal haulage vehicle, were 80% in mine R and 76% in mine S. Diesel particulate matter average control efficiencies, as measured in the diesel engine tailpipe, were 52% for mine R (for two ramcar vehicles) and 86% for mine S (for four ramcar vehicles). The air quality index control efficiencies, as measured by samplers located on the coal haulage vehicle were 48% in mine R and 51% in mine S. The exhaust quality index control efficiencies from tailpipe measurements were 45% for mine R and 63% for mine S. As measured by a high volume sampler in mine S, diesel particulate matter and associated organics and mutagenic activity were reduced approximately 50% with the use of the disposal diesel exhaust filter. Similar results were found with modified personal samplers in mine R. Little effect was found on relative removal of semivolatile organics. The disposal diesel exhaust filter resulted in about a 50% reduction in the most volatile polynuclear hydrocarbons; however, there appeared to be little effect on the less volatile polynuclear hydrocarbons. The disposable diesel exhaust filter appears to be very effective in reducing the levels of all the diesel exhaust particulate components, while having minor effects on the relative breakdown of the individual components of the particulate. 30 refs., 13 figs., 4 tabs.

  9. A user's evaluation of radial flow HEPA filters

    International Nuclear Information System (INIS)

    Purcell, J.A.

    1992-07-01

    High efficiency particulate air (HEPA) filters of rectangular cross section have been used to remove particulates and the associated radioactivity from air ventilation streams since the advent of nuclear materials processing. Use of round axial flow HEPA filters is also longstanding. The advantages of radial flow filters in a circular configuration have been well demonstrated in UKAEA during the last 5--7 years. An evaluation of radial flow filters for fissile process gloveboxes reveals several substantial benefits in addition to the advantages claimed in UKAEA Facilities. The radial flow filter may be provided in a favorable geometry resulting in improved criticality safety. The filter configuration lends to in-place testing at the glovebox to exhaust duct interface. This will achieve compliance with DOE Order 6430.1A, Section 99.0.2. Preliminary testing at SRS for radial flow filters manufactured by Flanders Filters, Inc. revealed compliance in all the usual specifications for filtration efficiency, pressure differential and materials of construction. An evaluation, further detailed in this report, indicates that the radial flow HEPA filter should be considered for inclusion in new ventilation system designs

  10. International Space Station (ISS) Bacterial Filter Elements (BFEs): Filter Efficiency and Pressure Testing of Returned Units

    Science.gov (United States)

    Green, Robert D.; Agui, Juan H.; Vijayakumar, R.

    2017-01-01

    The air revitalization system aboard the International Space Station (ISS) provides the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation due to the microgravity environment in Low Earth Orbit (LEO). The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Adsorption (HEPA) media filters deployed at multiple locations in each U.S. Segment module; these filters are referred to as Bacterial Filter Elements, or BFEs. These filters see a replacement interval, as part of maintenance, of 2-5 years dependent on location in the ISS. In this work, we present particulate removal efficiency, pressure drop, and leak test results for a sample set of 8 BFEs returned from the ISS after filter replacement. The results can potentially be utilized by the ISS Program to ascertain whether the present replacement interval can be maintained or extended to balance the on-ground filter inventory with extension of the lifetime of ISS beyond 2024. These results can also provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

  11. A Chemical-Biological-Radio-Nuclear (CBRN) Filter can be Added to the Air-Outflow Port of a Ventilator to Protect a Home Ventilated Patient From Inhalation of Toxic Industrial Compounds.

    Science.gov (United States)

    Be'eri, Eliezer; Owen, Simon; Beeri, Maurit; Millis, Scott R; Eisenkraft, Arik

    2018-02-21

    Chemical-biological-radio-nuclear (CBRN) gas masks are the standard means for protecting the general population from inhalation of toxic industrial compounds (TICs), for example after industrial accidents or terrorist attacks. However, such gas masks would not protect patients on home mechanical ventilation, as ventilator airflow would bypass the CBRN filter. We therefore evaluated in vivo the safety of adding a standard-issue CBRN filter to the air-outflow port of a home ventilator, as a method for providing TIC protection to such patients. Eight adult patients were included in the study. All had been on stable, chronic ventilation via a tracheostomy for at least 3 months before the study. Each patient was ventilated for a period of 1 hour with a standard-issue CBRN filter canister attached to the air-outflow port of their ventilator. Physiological and airflow measurements were made before, during, and after using the filter, and the patients reported their subjective sensation of ventilation continuously during the trial. For all patients, and throughout the entire study, no deterioration in any of the measured physiological parameters and no changes in measured airflow parameters were detected. All patients felt no subjective difference in the sensation of ventilation with the CBRN filter canister in situ, as compared with ventilation without it. This was true even for those patients who were breathing spontaneously and thus activating the ventilator's trigger/sensitivity function. No technical malfunctions of the ventilators occurred after addition of the CBRN filter canister to the air-outflow ports of the ventilators. A CBRN filter canister can be added to the air-outflow port of chronically ventilated patients, without causing an objective or subjective deterioration in the quality of the patients' mechanical ventilation. (Disaster Med Public Health Preparedness. 2018;page 1 of 5).

  12. 42 CFR 84.159 - Man tests for gases and vapors; supplied-air respirators; general performance requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests for gases and vapors; supplied-air respirators; general performance requirements. 84.159 Section 84.159 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES...

  13. Remote filter handling machine for Sizewell B

    International Nuclear Information System (INIS)

    Barker, D.

    1993-01-01

    Two Filter Handling machines (FHM) have been supplied to Nuclear Electric plc for use at Sizewell B Power Station. These machines have been designed and built following ALARP principles with the functional objective being to remove radioactive filter cartridges from a filter housing and replace them with clean filter cartridges. Operation of the machine is achieved by the prompt of each distinct task via an industrial computer or the prompt of a full cycle using the automatic mode. The design of the machine features many aspects demonstrating ALARP while keeping the machine simple, robust and easy to maintain. (author)

  14. Comparative performance of two air samplers for monitoring airborne fungal propagules

    Directory of Open Access Journals (Sweden)

    L.G.F. Távora

    2003-05-01

    Full Text Available Many studies have attempted to evaluate the importance of airborne fungi in the development of invasive fungal infection, especially for immunocompromised hosts. Several kinds of instruments are available to quantitate fungal propagule levels in air. We compared the performance of the most frequently used air sampler, the Andersen sampler with six stages, with a portable one, the Reuter centrifugal sampler (RCS. A total of 84 samples were analyzed, 42 with each sampler. Twenty-eight different fungal genera were identified in samples analyzed with the Andersen instrument. In samples obtained with the RCS only seven different fungal genera were identified. The three most frequently isolated genera in samples analyzed with both devices were Penicillium, Aspergillus and Cladophialophora. In areas supplied with a high efficiency particulate air filter, fungal spore levels were usually lower when compared to areas without these filters. There was a significant correlation between total fungal propagule measurements taken with both devices on each sampling occasion (Pearson coefficient = 0.50. However, the Andersen device recovered a broader spectrum of fungi. We conclude that the RCS can be used for quantitative estimates of airborne microbiological concentrations. For qualitative studies, however, this device cannot be recommended.

  15. Performance of multiple HEPA filters against plutonium aerosols

    International Nuclear Information System (INIS)

    Gonzales, M.; Elder, J.C.; Tillery, M.I.; Ettinger, H.J.

    1976-11-01

    Performance of multiple stages of high-efficiency particulate air (HEPA) filters has been verified against plutonium aerosols similar in size characteristics to those challenging the air-cleaning systems of plutonium-processing facilities. An experimental program was conducted to test each filter in systems of three HEPA filters operated in series against 238 PuO 2 aerosols as high as 3.3 x 10 10 dis/s . m 3 in activity concentration and ranging from 0.22 μm to 1.6 μm in activity median aerodynamic diameter (amad). Mean penetration (ratio of downstream to upstream concentration) of each of the three filters in series was below 0.0002, but it apparently increased at each successive filter. Penetration vs size measurements showed that maximum penetration of 238 PuO 2 occurred for sizes between 0.4- and 0.7-μm aerodynamic diameter (D/sub ae/). HEPA filter penetration at half of rated flow differed little from full-flow penetration

  16. Supplementary test method for carbon filters

    International Nuclear Information System (INIS)

    Normann, B.; Pettersson, S.-O.

    1980-11-01

    A test method for carbon filters using freon to detect leakage is described. The filters are used in nuclear power plants and in air-raid shelters to separate radioactive iodine.Sampling and detection limits are described and a proposal for a complete equipment is made.(G.B.)

  17. Experimental investigation on a turbine compressor for air supply system of a fuel cell

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Masayasu [Sumitomo Heavy Industries, Ltd., Yokosuka (Japan); Tsuchiyama, Syozo [Shipbuilding Research Association, Minato-ku, Tokyo (Japan)

    1996-12-31

    This report covers part of a joint study on a PEFC propulsion system for surface ships, summarized in a presentation to this Seminar, entitled {open_quotes}Study on a Polymer Electrolyte Fuel Cell (PEFC) Propulsion System for Surface Ships{close_quotes}, and which envisages application to a 1,500 DWT cargo vessel. The aspect treated here concerns a study on the air supply system for the PEFC, with particular reference to system components.

  18. Volume reduction of contaminated filter wastes

    International Nuclear Information System (INIS)

    Buttedahl, O.I.; Terada, K.

    1976-01-01

    Reported are details of a pilot project to design and construct a compactor to reduce the handling of high efficiency particulate air (HEPA) filters used in air filtration systems at facilities where radioactive materials are processed. In such systems at Rocky Flats Plant, filters require frequent change and removal. Large quantities are used and will be increased for future operations. With the completion of the pilot model, it has been demonstrated that volume reductions of more than 80% can be achieved and cost savings will be realized also

  19. The Economics of Some Types of Absolute Filters

    Energy Technology Data Exchange (ETDEWEB)

    Linder, P. J.; Skogulf, H. [Ab Atomenergi, Studsvir (Sweden)

    1968-12-15

    The cost of air-cleaning filters is determined by the purchase price of the filter and its mean life. If filter changes are not caused by a high level of activity, the increase in pressure drop will make a filter change necessary. In the latter case the dust-holding capacity of the filter determines the interval between changes. A number of different filters have been compared in this respect using atmospheric aerosols and a significant difference in cost has been observed. (author)

  20. Development and evaluation of a cleanable high efficiency steel filter

    International Nuclear Information System (INIS)

    Bergman, W.; Larsen, G.; Weber, F.; Wilson, P.; Lopez, R.; Valha, G.; Conner, J.; Garr, J.; Williams, K.; Biermann, A.; Wilson, K.; Moore, P.; Gellner, C.; Rapchun, D.; Simon, K.; Turley, J.; Frye, L.; Monroe, D.

    1993-01-01

    We have developed a high efficiency steel filter that can be cleaned in-situ by reverse air pulses. The filter consists of 64 pleated cylindrical filter elements packaged into a 6l0 x 6l0 x 292 mm aluminum frame and has 13.5 m 2 of filter area. The filter media consists of a sintered steel fiber mat using 2 μm diameter fibers. We conducted an optimization study for filter efficiency and pressure drop to determine the filter design parameters of pleat width, pleat depth, outside diameter of the cylinder, and the total number of cylinders. Several prototype cylinders were then built and evaluated in terms of filter cleaning by reverse air pulses. The results of these studies were used to build the high efficiency steel filter. We evaluated the prototype filter for efficiency and cleanability. The DOP filter certification test showed the filter has a passing efficiency of 99.99% but a failing pressure drop of 0.80 kPa at 1,700 m 3 /hr. Since we were not able to achieve a pressure drop less than 0.25 kPa, the steel filter does not meet all the criteria for a HEPA filter. Filter loading and cleaning tests using AC Fine dust showed the filter could be repeatedly cleaned by reverse air pulses. The next phase of the prototype evaluation consisted of installing the unit and support housing in the exhaust duct work of a uranium grit blaster for a field evaluation at the Y-12 Plant in Oak Ridge, TN. The grit blaster is used to clean the surface of uranium parts and generates a cloud of UO 2 aerosols. We used a 1,700 m 3 /hr slip stream from the 10,200 m 3 /hr exhaust system

  1. Antimicrobial Air Filters Using Natural Euscaphis japonica Nanoparticles.

    Directory of Open Access Journals (Sweden)

    Gi Byoung Hwang

    Full Text Available Controlling bioaerosols has become more important with increasing participation in indoor activities. Treatments using natural-product nanomaterials are a promising technique because of their relatively low toxicity compared to inorganic nanomaterials such as silver nanoparticles or carbon nanotubes. In this study, antimicrobial filters were fabricated from natural Euscaphis japonica nanoparticles, which were produced by nebulizing E. japonica extract. The coated filters were assessed in terms of pressure drop, antimicrobial activity, filtration efficiency, major chemical components, and cytotoxicity. Pressure drop and antimicrobial activity increased as a function of nanoparticle deposition time (590, 855, and 1150 µg/cm2(filter at 3-, 6-, and 9-min depositions, respectively. In filter tests, the antimicrobial efficacy was greater against Staphylococcus epidermidis than Micrococcus luteus; ~61, ~73, and ~82% of M. luteus cells were inactivated on filters that had been coated for 3, 6, and 9 min, respectively, while the corresponding values were ~78, ~88, and ~94% with S. epidermidis. Although statistically significant differences in filtration performance were not observed between samples as a function of deposition time, the average filtration efficacy was slightly higher for S. epidermidis aerosols (~97% than for M. luteus aerosols (~95%. High-performance liquid chromatography (HPLC and electrospray ionization-tandem mass spectrometry (ESI/MS analyses confirmed that the major chemical compounds in the E. japonica extract were 1(ß-O-galloyl pedunculagin, quercetin-3-O-glucuronide, and kaempferol-3-O-glucoside. In vitro cytotoxicity and disk diffusion tests showed that E. japonica nanoparticles were less toxic and exhibited stronger antimicrobial activity toward some bacterial strains than a reference soluble nickel compound, which is classified as a human carcinogen. This study provides valuable information for the development of a

  2. Absolute air filtering equipment in the nuclear industrie. Design - Safety - Experience

    International Nuclear Information System (INIS)

    Lucas, J.C.

    1977-01-01

    The problems encountered in the design of absolute filters (HEPA FILTERS) are presented: glass-fibre filter papers; standards and characteristics: efficiency, fire-resistance, humidity-resistance, radiation-resistance, etc; various types of paper folding: deep folds and small folds, dihedrally mounted; filtering elements; designs; characteristics and quality control; The design of filtration equipment is also analysed: mounting in metal or concrete casings. French and American designs (Regulatory Guide 1-52); and gas-tight casings allowing contaminated filters to be renewed without breaking the gas-tight seal

  3. 75 FR 7345 - Filtered Flight Data

    Science.gov (United States)

    2010-02-19

    ... digital flight data recorder regulations affecting certain air carriers and operators. This final rule prohibits the filtering of some original flight recorder sensor signals unless a certificate holder can show... A. Verna, Avionics Systems Branch, Aircraft Certification Service, AIR-130, Federal Aviation...

  4. Result of desalinating filter performance at representative coastal area

    International Nuclear Information System (INIS)

    Ohtake, Nobuyosi; Wada, Tadamasa

    1989-01-01

    In Japan, Nuclear energy facilities are usually located within 1 km from sea shore. Lately, manufacturing plants for semiconductors and precision machines have also taken locations at the sea side. At these locations, salt particles coming from the sea flow into a plant through its air-intakes. This is a problem, because if can cause electric equipment and other important equipment to deteriorate and may influence production yield. An effective solution to this problem is to install a filter at the air-intake. However, few data in this area is available, because the salt concentration in the air is too low to verify acutual affects of installed filters. This report describes the performance of a filter system installed in an actual building located 300 m from the sea shore. We used a radioactivation analysis method with a detection limit up to 0.01 μg/m 3 to measure concentrations at the up stream and down stream of the filter. A flame spectrochemical analysis measured salt adhering to filter materials. The particle collection performance averaged 80 % for the prefilter and 90 % for a desalinating filter. We also investigated the possibility that captured NaCl might rescatter with the deliquescence due to high humidity, and we found this phenomenon at least in the prefilter. (author)

  5. Optimized control strategy for crowbarless solid state modular power supply

    International Nuclear Information System (INIS)

    Upadhyay, R.; Badapanda, M.K.; Tripathi, A.; Hannurkar, P.R.; Pithawa, C.K.

    2009-01-01

    Solid state modular power supply with series connected IGBT based power modules have been employed as high voltage bias power supply of klystron amplifier. Auxiliary compensation of full wave inverter bridge with ZVS/ZCS operations of all IGBTs over entire operating range is incorporated. An optimized control strategy has been adopted for this power supply needing no output filter, making this scheme crowbarless and is presented in this paper. DSP based fully digital control with same duty cycle for all power modules, have been incorporated for regulating this power supply along with adequate protection features. Input to this power supply is taken directly from 11 kV line and the input system is intentionally made 24 pulsed to reduce the input harmonics, improve the input power factor significantly, there by requiring no line filters. Various steps have been taken to increase the efficiency of major subsystems, so as to improve the overall efficiency of this power supply significantly. (author)

  6. Radiation protective clothing

    International Nuclear Information System (INIS)

    Watanabe, Choshin; Takaura, Katsutoshi

    1998-01-01

    An external clothing as a main portion of the radiation protective clothing of the present invention is adapted to cover substantially the entire body of a wearer, comprises a moisture permeable material partially or entirely, and has an air supply device equipped with a filter for feeding air to a head portion of the wearer in the external clothing. Cleaned air filtered by the filter is supplied to the head portion of a wearer in the external clothing. The air passes through remarkably perspiratory head, face, shoulder, chest and back portions to remove heat and sweat at sensitively important upper portions of a body, so that humidity is released to remove fatigues and improve workability. In addition, since some extent of internal pressure is exerted to the inside of the external clothing by the air supply, contaminated air does not intrude from the outside to the external clothing. Since the air supply device is attached and carried to the external clothing, there is no air line hose which disturbs operation. (I.S.)

  7. Experimental investigation of in situ cleanable HEPA filters

    International Nuclear Information System (INIS)

    Adamson, D.J.

    2000-01-01

    Savannah River Technology Center (SRTC), High Level Waste Division, Tanks Focus Area, and the Federal Energy Technology Center (FETC) have been investigating high efficiency particulate air (HEPA) filters which can be regenerated or cleaned in situ as an alternative to conventional disposable HEPA filters. This technical report documents concerns pertaining to conventional HEPA filters

  8. Analog Electronic Filters Theory, Design and Synthesis

    CERN Document Server

    Dimopoulos, Hercules G

    2012-01-01

    Filters are essential subsystems in a huge variety of electronic systems. Filter applications are innumerable; they are used for noise reduction, demodulation, signal detection, multiplexing, sampling, sound and speech processing, transmission line equalization and image processing, to name just a few. In practice, no electronic system can exist without filters. They can be found in everything from power supplies to mobile phones and hard disk drives and from loudspeakers and MP3 players to home cinema systems and broadband Internet connections. This textbook introduces basic concepts and methods and the associated mathematical and computational tools employed in electronic filter theory, synthesis and design.  This book can be used as an integral part of undergraduate courses on analog electronic filters. Includes numerous, solved examples, applied examples and exercises for each chapter. Includes detailed coverage of active and passive filters in an independent but correlated manner. Emphasizes real filter...

  9. Strontium-90 determination in air dust filter using solid phase extraction after the accident of FD-NPS

    International Nuclear Information System (INIS)

    Zhang, Zijian; Kakitani, Shunsuke; Ninomiya, Kazuhiko

    2013-01-01

    Radioactivities of Sr-90 in air-dust filters collected in Hitachi, Kawasaki and Toyonaka were determined using solid state extraction method and low background beta-ray counting system. In Hitachi, though the Sr-90 activity concentration was decreased with time, the activity rates of Sr-90/Cs-137 kept about 10"-"3 order. This fact suggests that Sr-90 transportation behavior in the atmosphere is similar to that of Cs-137 during the time of sample collection. (author)

  10. The control of a biotrickling filter

    NARCIS (Netherlands)

    van Lith, C.P.M.; Ottengraf, S.P.P.; Diks, R.M.M.

    1994-01-01

    Emissions from composting plants must be reduced with high efficiencies by means of closed systems and treatment of ventilation air. Biofilters are used for air treatment, however these systems have several disadvantages, e.g. large required filter mols. and low controllability. A promising new

  11. Air conditioner for radioactive material handling facility

    International Nuclear Information System (INIS)

    Tanaka, Takeaki.

    1991-01-01

    An air conditioner intakes open-air from an open-air intake port to remove sands and sea salt particles by air filters. Then, natural and artificial radioactive particles of less than 1 μm are removed by high performance particulate filters. After controlling the temperature by an air heater or an air cooler, air is sent to each of chambers in a facility under pressure elevation by a blower. In this case, glass fibers are used as the filter material for the high performance particulate filter, which has a performance of more than 99.97% for the particles of 0.3 μm grain size. Since this can sufficiently remove the natural radioactive materials intruded from the outside, a detection limit value in each of the chambers of the facility can be set 10 -13 to 10 -14 μci/cm 3 in respect of radiation control. Accordingly, radiation control can be conducted smoothly and appropriately. (I.N.)

  12. In-duct countermeasures for reducing fire-generated-smoke-aerosol exposure to HEPA filters

    International Nuclear Information System (INIS)

    Alvares, N.J.; Beason, D.G.; Ford, H.W.

    1978-01-01

    An experimental program was conducted to assess the endurance and lifetime of HEPA filters exposed to fire-generated aerosols, and to reduce the aerosol exposure by installing engineering countermeasures in the duct between the fire source and HEPA filters. Large cribs of wood and other potential fuels of interest were ''forcefully burned'' in a partially ventilated enclosure. In a ''forceful burn'' the crib of fuel is continuously exposed to an energetic premixed methane flame during the entire experimental period. This tactic serves two purposes: it optimizes the production of smoke rich in unburned pyrolyzates which provides severe exposure to the filters, and it facilitates the ignition and enhances the combustion of cribs formed with synthetic polymers. The experiments were conducted in an enclosure specifically designed and instrumented for fire tests. The test cell has a volume of 100 m 3 and includes instrumentation to measure the internal temperature distribution, pressure, thermal radiation field, flow fields, gas concentration, particulate size distribution and mass, fuel weight loss, inlet and exit air velocities, and smoke optical density. The countermeasure techniques include the use of passively operated sprinkler systems in the fire test cell, of fine and dense water scrubbing sprays, and of rolling prefiltration systems in the exit duct of the fire test cell. Of the countermeasures surveyed, the rolling prefilter system showed the most promise. This paper concentrates on the effect of control variables; i.e., enclosure air supply, fuel composition and crib porosity on the combustion response; i.e., crib burning rate, enclosure temperature rise, oxygen consumption, and CO, CO 2 and total hydrocarbon production. A discussion of the attempts to rationalize smoke aerosol properties will be included along with results from the effect of countermeasure application on HEPA filter lifetimes

  13. Multi-parameter studies of environmental aerosols with cascade track filters

    International Nuclear Information System (INIS)

    Ensinger, W.; Guo, S.-L.; Vater, P.; Brandt, R.

    2005-01-01

    Aerosols in the air in a factory processing nuclear reactor fuel material were collected by using cascade Kapton track filters with outer pore sizes of 12.8, 4.0 and 1.0μm consecutively and a conventional filter of glass fiber being behind to collect all aerosol particles left-over. The volume of air passed through the filters was measured by a flow meter. The weight of aerosol particles on each filter was obtained by the weight difference of the filter before and after collection of aerosol particles. α-activity on each filter was measured with a methane gas flow proportional counter. The sizes and elemental compositions of aerosol particles on the filters were analyzed by using a scanning electron microscope and an electron microprobe. Special attention was given to uranium aerosol particles. The median sizes of uranium aerosol particles were obtained being 1.97, 1.33 and 0.72μm on the first, second and third filter, respectively. The median size of all the uranium aerosol particles on the three track filters was 1.25μm

  14. Penetration of HEPA filters by alpha recoil aerosols

    International Nuclear Information System (INIS)

    McDowell, W.J.; Seeley, F.G.; Ryan, M.T.

    1976-01-01

    Tests at Oak Ridge National Laboratory confirmed that alpha-emitting particulate matter does penetrate high-efficiency filter medium, identical to that used in HEPA filters, much more effectively than do non-radioactive or beta-gamma active aerosols. Filter retention efficiencies drastically lower than the 99.97 percent quoted for ordinary particulate matter have been observed with 212 Pb, 253 Es, and 238 Pu sources, indicating that the phenomenon is common to all of these and probably to all alpha-emitting materials of appropriate half-life. Results with controlled air-flow through filters in series are consistent with the picture of small particles dislodged from the ''massive'' surface of an alpha-active material, and then repeatedly dislodged from positions on the filter fibers, by the alpha recoils. The process shows only a small dependence on the physical form of the source material. Oxide dust, nitrate salt, and plated metal all seem to generate the recoil particles effectively. The amount penetrating a series of filters depends on the total amount of activity in the source material, its specific activity, and the length of time of air flow. Dependence on the air flow velocity is slight. It appears that this phenomenon has not been observed in previous experiments with alpha-active aerosols because the tests did not continue for a sufficiently long time. A theoretical model of the process has been developed, amenable to computer handling, that should allow calculation of the rate constants associated with the transfer through and release of radioactive material from a filter system by this process

  15. PENGELOLAAN MATA AIR UNTUK PENYEDIAAN AIR RUMAHTANGGA BERKELANJUTAN DI LERENG SELATAN GUNUNGAPI MERAPI (Springs Management for Sustainability Domestic Water Supply in the South West of Merapi Volcano Slope

    Directory of Open Access Journals (Sweden)

    Sudarmadji Sudarmadji

    2016-02-01

    Full Text Available ABSTRAK Mata air merupakan pemunculan air tanah ke permukaan tanah. Pemanfaatan mata air sangat beragam, antara lain penggunaan untuk keperluan air minum, irigasi, perikanan, untuk obyek wisata. Mata air mempunyai debit terbatas, namun kualitasnya baik, penggunaannya beragam, hal tersebut sering terjadi konflik pemanfaatan. Di saat musim kemarau, beberapa mata air merupakan sumber air satu-satunya di suatu tempat, sehingga pengelolaannya harus dilakukan secara baik. Penelitian ini bertujuan untuk mempelajari pengelolaan mata air berbasis teknologi tepat guna dalam penyediaan air rumahtangga di lereng selatan Gunungapi Merapi. Penelitian dilakukan dengan survei dan observasi di lapangan terhadap mata air yang digunakan untuk penyediaan air rumahtangga. Sejumlah responden pengguna mata air dan tokoh masyarakat setempat diwawancarai secara bebas dan terstruktur untuk memperoleh data pengelolaan mata air. Hasil penelitian menunjukkan bahwa kondisi lingkungan dan karakteristik mata air, pengetahuan masyarakat dan budaya lokal yang beragam akan berpengaruh terhadap pengelolaanmata air. Perkembangan teknologi tidak dapat diabaikan dalam pengelolaan sumberdaya air. Hal ini dapat dipadukan dengan budaya masyarakat setempat dalam pengelolaan mata air, sehingga dapat diperoleh manfaat yang optimal dan kesinambungan fungsi dan manfaat mata air tersebut.   ABSTRACT Spring is the groundwater which comes out on ground surface. The use of water from springs is very diverse, varying from water for drinking, irrigation, fisheries, even for tourism. The springs usually have a limited discharge but the water quality from springs is good, therefore they are often facing some conflicts in utilization. In the dry season, in fact the springs are the only source of water supply; therefore the management of the spring should be done properly. This research aims to study the spring management based on appropriate technology in relation to household water supply in the

  16. Discontinuous Mode Power Supply

    Science.gov (United States)

    Lagadinos, John; Poulos, Ethel

    2012-01-01

    A document discusses the changes made to a standard push-pull inverter circuit to avoid saturation effects in the main inverter power supply. Typically, in a standard push-pull arrangement, the unsymmetrical primary excitation causes variations in the volt second integral of each half of the excitation cycle that could lead to the establishment of DC flux density in the magnetic core, which could eventually cause saturation of the main inverter transformer. The relocation of the filter reactor normally placed across the output of the power supply solves this problem. The filter reactor was placed in series with the primary circuit of the main inverter transformer, and is presented as impedance against the sudden changes on the input current. The reactor averaged the input current in the primary circuit, avoiding saturation of the main inverter transformer. Since the implementation of the described change, the above problem has not reoccurred, and failures in the main power transistors have been avoided.

  17. Response of HEPA filters to simulated-accident conditions

    International Nuclear Information System (INIS)

    Gregory, W.S.; Martin, R.A.; Smith, P.R.; Fenton, D.E.

    1982-01-01

    High-efficiency particulate air (HEPA) filters have been subjected to simulated accident conditions to determine their response to abnormal operating events. Both domestic and European standard and high-capacity filters have been evaluated to determine their response to simulated fire, explosion, and tornado conditions. The HEPA filter structural limitations for tornado and explosive loadings are discussed. In addition, filtration efficiencies during these accident conditions are reported for the first time. Our data indicate efficiencies between 80% and 90% for shock loadings below the structural limit level. We describe two types of testing for ineffective filtration - clean filters exposed to pulse-entrained aerosol and dirty filters exposed to tornado and shock pulses. Efficiency and material loss data are described. Also, the resonse of standard HEPA filters to simulated fire conditions is presented. We describe a unique method of measuring accumulated combustion products on the filter. Additionally, data relating to pressure drop vs accumulated mass during plugging are reported for simulated combustion aerosols. The effects of concentration and moisture levels on filter plugging were evaluated. We are obtaining all of the above data so that mathematical models can be developed for fire, explosion, and tornado accident analysis computer codes. These computer codes can be used to assess the response of nuclear air cleaning systems to accident conditions

  18. The case for improved HEPA-filter mechanical performance standards revisited

    Energy Technology Data Exchange (ETDEWEB)

    Ricketts, C.I.; Smith, P.R. [New Mexico State Univ., Las Cruces, NM (United States)

    1997-08-01

    Under benign operating conditions, High Efficiency Particulate Air (HEPA) filter units serve as reliable and relatively economical components in the air cleaning systems of nuclear facilities worldwide. Despite more than four decades of filter-unit evaluation and improvements, however, the material strength characteristics of the glass fiber filter medium continue to ultimately limit filter functional reliability. In worst-case scenarios involving fire suppression, loss-of-coolant accidents (LOCA`s), or exposure to shock waves or tornado induced flows, rupture of the filter medium of units meeting current qualification standards cannot be entirely ruled out. Even under so-called normal conditions of operation, instances of filter failure reported in the literature leave open questions of filter-unit reliability. Though developments of filter units with improved burst strengths have been pursued outside the United States, support for efforts in this country has been comparatively minimal. This despite user requests for filters with greater moisture resistance, for example. Or the fact that conventional filter designs result in not only the least robust component to be found in a nuclear air cleaning system, but also the one most sensitive to the adverse effects of conditions deviating from those of normal operation. Filter qualification-test specifications of current codes, standards, and regulatory guidelines in the United States are based primarily upon research performed in a 30-year period beginning in the 1950`s. They do not seem to reflect the benefits of the more significant developments and understanding of filter failure modes and mechanisms achieved since that time. One overseas design, based on such knowledge, has proven reliability under adverse operating conditions involving combined and serial challenges. Its widespread use, however, has faltered on a lack of consensus in upgrading filter performance standards. 34 refs., 2 figs., 3 tabs.

  19. Compressed breathing air - the potential for evil from within.

    Science.gov (United States)

    Millar, Ian L; Mouldey, Peter G

    2008-06-01

    Human underwater activities rely on an adequate supply of breathable compressed gas, usually air, free from contaminants that could cause incapacitation underwater or post-dive or longer-term health effects. Potentially fatal but well-known hazards are hypoxia secondary to steel cylinder corrosion and carbon monoxide (CO) poisoning due to contaminated intake air. Another phenomenon may be behind some previously unexplained episodes of underwater incapacitation and perhaps death: low-level CO poisoning and/or the effects of gaseous contaminants generated within the compressor, including toluene and other volatile compounds. Many low molecular weight volatile contaminants are anaesthetic and will be potentiated by pressure and nitrogen narcosis. In sub-anaesthetic doses, impaired judgement, lowered seizure threshold and sensitisation of the heart to arrhythmias may occur. Toxic compounds can be volatilised from some compressor oils, especially mineral oils, in overheated compressors, or be created de novo under certain combinations of temperature, humidity and pressure, perhaps catalysed by metal traces from compressor wear and tear. Most volatiles can be removed by activated carbon filtration but many filters are undersized and may overload in hot, moist conditions and with short dwell times. A compressor that passes normal testing could contaminate one or more cylinders after heating up and then return to producing clean air as the filters dry and the systems cool. The scope of this problem is very unclear as air quality is tested infrequently and often inadequately, even after fatalities. More research is needed as well as better education regarding the safe operation and limitations of high-pressure breathing air compressors.

  20. Application of Micropore Filter Technology: Exploring the Blood Flow Path in Arterial-Line Filters and Its Effect on Bubble Trapping Functions.

    Science.gov (United States)

    Herbst, Daniel P

    2017-03-01

    Conventional arterial-line filters commonly use a large volume circular shaped housing, a wetted micropore screen, and a purge port to trap, separate, and remove gas bubbles from extracorporeal blood flow. Focusing on the bubble trapping function, this work attempts to explore how the filter housing shape and its resulting blood flow path affect the clinical application of arterial-line filters in terms of gross air handling. A video camera was used in a wet-lab setting to record observations made during gross air-bolus injections in three different radially designed filters using a 30-70% glycerol-saline mixture flowing at 4.5 L/min. Two of the filters both had inlet ports attached near the filter-housing top with bottom oriented outlet ports at the bottom, whereas the third filter had its inlet and outlet ports both located at the bottom of the filter housing. The two filters with top-in bottom-out fluid paths were shown to direct the incoming flow downward as it passed through the filter, placing the forces of buoyancy and viscous drag in opposition to each other. This contrasted with the third filter's bottom-in bottom-out fluid path, which was shown to direct the incoming flow upward so that the forces of buoyancy and viscous drag work together. The direction of the blood flow path through a filter may be important to the application of arterial-line filter technology as it helps determine how the forces of buoyancy and flow are aligned with one another.

  1. Permanently magnetized high gradient magnetic air filters for the nuclear industry

    International Nuclear Information System (INIS)

    Watson, J.H.P.

    1995-01-01

    This paper describes the structure and testing of two novel permanently magnetized magnetic filters for fine radioactive material. In the first filter the holes in the filter are left open as capture proceeds which means the pressure drop builds up only slowly. This filter is not suitable for composite particles which can be broken by mechanical forces. The second filter has been changed so as to strongly capture particles composed of fine particles weakly bound together which tend to break when captured. This uses a principle of assisted capture in which coarse particles aid the capture of the fine fragments. These filters have the following characteristics: (1) no external magnet is required, (2) no external power is required, (3) small in size and portable, (4) easily interchangeable, and (5) can be cleaned without demagnetizing by using a magnetic fluid which matches the susceptibility of the captured particles

  2. Harmonic filter design consideration for a tire-rubber factory

    Energy Technology Data Exchange (ETDEWEB)

    Zebardast, A. [Azad Univ., Tehran (Iran, Islamic Republic of). Abhar Branch]|[Sharif Univ., Tehran (Iran, Islamic Republic of); Mokhtari, H. [Azad Univ., Tehran (Iran, Islamic Republic of)

    2005-07-01

    Nonlinear loads and arc furnace loads are the main sources of harmonic currents in power distribution systems. Harmonic currents can cause reductions in system efficiency, and shorten the lifespan of transformers and capacitor banks. This paper provided details of a filter designed to attenuate harmonic currents at a tire company in Iran. The tire company was supplied by 3 distribution transformers and an emergency transformer. Main supply was through a 132 kV/20 kV transformer, which was connected to 2 A and B stations. The AC/DC drivers generated harmonics. Harmonic measurements were performed to determine the type and size of the required filters. A summary of site harmonic measurements was provided. A passive filter was placed at a medium voltage location. A sensitivity analysis was then performed in order to assess loading effects on filter performance. The analysis was performed on all possible configurations in the plant, including load change, capacitor bank step change, and transformer energization. Resonance conditions were also examined. Results showed that attention must be paid to the filter component rating in addition to potential resonant conditions. It was concluded that resonant conditions alter when system operating conditions change. 5 refs., 7 figs.

  3. Using the Estimating Supplies Program to Develop Materiel Solutions for the U.S. Air Force Aeromedical Evacuation In-Flight Kit (FFQDM)

    National Research Council Canada - National Science Library

    Hopkins, Curtis; Nix, Ralph; Pang, Gerry; Konoske, Paula

    2008-01-01

    ... NHRC's medical modeling tool the Estimating Supplies Program (ESP) for the development and management of Air Force medical Allowance Standards as a baseline for standardization throughout the services...

  4. Multiple HEPA filter test methods, January--December 1976

    International Nuclear Information System (INIS)

    Schuster, B.; Kyle, T.; Osetek, D.

    1977-06-01

    The testing of tandem high-efficiency particulate air (HEPA) filter systems is of prime importance for the measurement of accurate overall system protection factors. A procedure, based on the use of an intra-cavity laser particle spectrometer, has been developed for measuring protection factors in the 10 8 range. A laboratory scale model of a filter system was constructed and initially tested to determine individual HEPA filter characteristics with regard to size and state (liquid or solid) of several test aerosols. Based on these laboratory measurements, in-situ testing has been successfully conducted on a number of single and tandem filter installations within the Los Alamos Scientific Laboratory as well as on extraordinary large single systems at Rocky Flats. For the purpose of recovery and for simplified solid waste disposal, or prefiltering purposes, two versions of an inhomogeneous electric field air cleaner have been devised and are undergoing testing. Initial experience with one of the systems, which relies on an electrostatic spraying phenomenon, indicates performance efficiency of greater than 99.9% for flow velocities commonly used in air cleaning systems. Among the effluents associated with nuclear fuel reprocessing is 129 I. An intra-cavity laser detection system is under development which shows promise of being able to detect mixing ratios of one part in 10 7 , I 2 in air

  5. Preliminary studies to determine the shelf life of HEPA filters. Revision 1

    International Nuclear Information System (INIS)

    Gilbert, H.; Fretthold, J.K.; Rainer, F.; Bergman, W.; Beason, D.

    1995-02-01

    We have completed a preliminary study using filter media tests and filter qualification tests to investigate the effect of shelf-life on HEPA filter performance. Our media studies showed that the tensile strength decreased with age, but the data were not sufficient to establish a shelf-life. Thermogravimetric analyses demonstrated that one manufacturer had media with low tensile strength due to insufficient binder. The filter qualification tests (heated air and overpressure) conducted on different aged filters showed that filter age is not the primary factor affecting filter performance; materials and the construction design have a greater effect. An unexpected finding of our study was that sub-standard HEPA filters have been installed in DOE facilities despite existing regulations and filter qualification tests. We found that the filter with low tensile strength failed the overpressure test. The same filter had passed the heated air test, but left the filter so structurally weak, it was prone to blow-out. We recommend that DOE initiate a filter qualification program to prevent this occurrence

  6. HEPA Filter Vulnerability Assessment

    International Nuclear Information System (INIS)

    GUSTAVSON, R.D.

    2000-01-01

    This assessment of High Efficiency Particulate Air (HEPA) filter vulnerability was requested by the USDOE Office of River Protection (ORP) to satisfy a DOE-HQ directive to evaluate the effect of filter degradation on the facility authorization basis assumptions. Within the scope of this assessment are ventilation system HEPA filters that are classified as Safety-Class (SC) or Safety-Significant (SS) components that perform an accident mitigation function. The objective of the assessment is to verify whether HEPA filters that perform a safety function during an accident are likely to perform as intended to limit release of hazardous or radioactive materials, considering factors that could degrade the filters. Filter degradation factors considered include aging, wetting of filters, exposure to high temperature, exposure to corrosive or reactive chemicals, and exposure to radiation. Screening and evaluation criteria were developed by a site-wide group of HVAC engineers and HEPA filter experts from published empirical data. For River Protection Project (RPP) filters, the only degradation factor that exceeded the screening threshold was for filter aging. Subsequent evaluation of the effect of filter aging on the filter strength was conducted, and the results were compared with required performance to meet the conditions assumed in the RPP Authorization Basis (AB). It was found that the reduction in filter strength due to aging does not affect the filter performance requirements as specified in the AB. A portion of the HEPA filter vulnerability assessment is being conducted by the ORP and is not part of the scope of this study. The ORP is conducting an assessment of the existing policies and programs relating to maintenance, testing, and change-out of HEPA filters used for SC/SS service. This document presents the results of a HEPA filter vulnerability assessment conducted for the River protection project as requested by the DOE Office of River Protection

  7. Numerical Study on Self-Cleaning Canister Filter With Add-On Filter Cap

    Directory of Open Access Journals (Sweden)

    Mohammed Akmal Nizam

    2017-01-01

    Full Text Available Filtration in a turbo machinery system such as a gas turbine will ensure that the air entering the inlet is free from contaminants that could bring damage to the main system. Self-cleaning filter systems for gas turbines are designed for continuously efficient flow filtration. A good filter would be able to maintain its effectiveness over a longer time period, prolonging the duration between filter replacements and providing lower pressure drop over its operating lifetime. With this goal in mind, the current study is focused on the difference in pressure loss of the benchmark Salutary Avenue Self-cleaning filter in comparison to a new design with an add-on filter cap. Geometry for the add-on filter cap will be based from Salutary Avenue Manufacturing Sdn.Bhd. SOLIDWORKS software was used to model the geometry of the filter, while simulation analysis on the flow through the filter was done using Computational Fluid Dynamic (CFD software. The simulations are based on a low velocity condition, in which the parameter for the inlet velocity are set at 0.032 m/s, 0.063 m/s, 0.094 m/s and 0.126 m/s respectively. From the simulation data obtained for the inlet velocities considered, the pressure drop reduction of the modified filter compared to the benchmark was found to be between 7.59% and 30.18%. All in all, the modification of the filter cap produced a lower pressure drop in comparison with the benchmark filter; an improvement of 27.02% for the total pressure drop was obtained.

  8. In Situ Cleanable Alternative HEPA Filter Media

    International Nuclear Information System (INIS)

    Adamson, D. J.; Terry, M. T.

    2002-01-01

    The Westinghouse Savannah River Company, located at the Savannah River Site in Aiken, South Carolina, is currently testing two types of filter media for possible deployment as in situ regenerable/cleanable High Efficiency Particulate Air (HEPA) filters. The filters are being investigated to replace conventional, disposable, glass-fiber, HEPA filters that require frequent removal, replacement, and disposal. This is not only costly and subjects site personnel to radiation exposure, but adds to the ever-growing waste disposal problem. The types of filter media being tested, as part of a National Energy Technology Laboratory procurement, are sintered nickel metal and ceramic monolith membrane. These media were subjected to a hostile environment to simulate conditions that challenge the high-level waste tank ventilation systems. The environment promoted rapid filter plugging to maximize the number of filter loading/cleaning cycles that would occur in a specified period of time. The filters were challenged using nonradioactive simulated high-level waste materials and atmospheric dust; materials that cause filter pluggage in the field. The filters are cleaned in situ using an aqueous solution. The study found that both filter media were insensitive to high humidity or moisture conditions and were easily cleaned in situ. The filters regenerated to approximately clean filter status even after numerous plugging and in situ cleaning cycles. Air Techniques International is conducting particle retention testing on the filter media at the Oak Ridge Filter Test Facility. The filters are challenged using 0.3-mm di-octyl phthalate particles. Both the ceramic and sintered media have a particle retention efficiency > 99.97%. The sintered metal and ceramic filters not only can be cleaned in situ, but also hold great potential as a long life alternative to conventional HEPA filters. The Defense Nuclear Facility Safety Board Technical Report, ''HEPA Filters Used in the Department of

  9. Process and device for regulating an electromagnetic filter

    International Nuclear Information System (INIS)

    Dolle, Lucien.

    1980-01-01

    Process for regulating the operation of an electromagnetic filter and, in particular, for keeping the efficiency of the filter at a sufficiently high level irrespective of the degree of filter clogging, fluid flow rate and temperature of the fluid. The filter includes an envelope containing a filling that can be magnetized by a coil activated by a d.c. supply arranged around the envelope. The regulating process includes the following stages: - activating the coil by a current of lower intensity than that of the saturation current of the filling, - determining the pressure drop of the filter, fluid flow rate and fluid temperature, - increasing the intensity of the current activating the coil when the efficiency of the filter corresponding to the measured values drops below a given level [fr

  10. Method of mounting filter elements and mounting therefor

    International Nuclear Information System (INIS)

    Karelin, J.; Neumann, G.M.

    1981-01-01

    A process for the insertion and exchange of the filter elements for suspended matter is performed from the clean-air-side. During the insertion of a filter element, a plastic tube (Which encircles the circumference of the filter element and which exceeds in its length the layer thickness of the filter element several times) is tightly connected in its middle section with the side walls, which side walls form a border around the filter element; and then the open end of the plastic tube, which faces the frame, is connected by way of a tight fit with a ring, which is actually known and which surrounds the orifice of the frame into which the filter element is inserted. The filter element is connected with the frame by means of tightening devices, and the outer free end of the tube is turned inside out and around the filter element for the purpose of unhindered air passage through the filter layer, that during the exchange of the contaminated filter element, the outer open end of the tube is heat sealed. The filter element is disconnected and removed from the frame by flipping down of the tightening devices, and the tube is heat sealed in the section between the filter element and the frame, and, that during the insertion of a new filter element, a new tube is attached by way of tight fitting to the ring of the frame , which tube is at its middle section tightly connected with the filter element, and which tube is attached to the ring of the frame in an actually known by overlapping of the heat-sealed tube rest. The tube rest is pulled onto the new tube and pulled off the ring, and the filter element is tightly connected with the frame by means of the tightening devices

  11. Filter Paper: Solution to High Self-Attenuation Corrections in HEPA Filter Measurements

    International Nuclear Information System (INIS)

    Oberer, R.B.; Harold, N.B.; Gunn, C.A.; Brummett, M.; Chaing, L.G.

    2005-01-01

    An 8 by 8 by 6 inch High Efficiency Particulate Air (HEPA) filter was measured as part of a uranium holdup survey in June of 2005 as it has been routinely measured every two months since 1998. Although the survey relies on gross gamma count measurements, this was one of a few measurements that had been converted to a quantitative measurement in 1998. The measurement was analyzed using the traditional Generalized Geometry Holdup (GGH) approach, using HMS3 software, with an area calibration and self-attenuation corrected with an empirical correction factor of 1.06. A result of 172 grams of 235 U was reported. The actual quantity of 235 U in the filter was approximately 1700g. Because of this unusually large discrepancy, the measurement of HEPA filters will be discussed. Various techniques for measuring HEPA filters will be described using the measurement of a 24 by 24 by 12 inch HEPA filter as an example. A new method to correct for self attenuation will be proposed for this measurement Following the discussion of the 24 by 24 by 12 inch HEPA filter, the measurement of the 8 by 8 by 6 inch will be discussed in detail

  12. Evaluation of HEPA filter service life

    International Nuclear Information System (INIS)

    Fretthold, J.K.; Stithem, A.R.

    1997-01-01

    Rocky Flats Environmental Technology Site (RFETS), has approximately 10,000 High Efficiency Particulate Air (HEPA) Filters installed in a variety of filter plenums. These ventilation/filtration plenum systems are used to control the release of airborne particulate contaminates to the environment during normal operations and potential accidents. This report summarizes the results of destructive and non-destructive tests on HEPA filters obtained from a wide variety of ages and service conditions. These tests were performed to determine an acceptable service life criteria for HEPA filters used at Rocky Flats Environmental Technology Site (RFETS). A total of 140 filters of various ages (1972 to 1996) and service history (new, aged unused, used) were tested. For the purpose of this report, filter age from manufacture date/initial test date to the current sample date was used, as opposed to the actual time a filter was installed in an operating system

  13. Unit for air decontamination

    International Nuclear Information System (INIS)

    Mariano H, E.

    1991-02-01

    To fulfill the applicable requirements of safety to the ventilation systems in nuclear facilities, it is necessary to make a cleaning of the air that hurtles to the atmosphere. For that which was designed and it manufactured an unit for decontamination of the air for the Pilot plant of production of Nuclear Fuel that this built one with national parts, uses Hepa national filters and the design can adapt for different dimensions of filters, also can be added a lodging for a prefilter or to adopt two Hepa filters. (Author)

  14. Filtering Redundant Data from RFID Data Streams

    Directory of Open Access Journals (Sweden)

    Hazalila Kamaludin

    2016-01-01

    Full Text Available Radio Frequency Identification (RFID enabled systems are evolving in many applications that need to know the physical location of objects such as supply chain management. Naturally, RFID systems create large volumes of duplicate data. As the duplicate data wastes communication, processing, and storage resources as well as delaying decision-making, filtering duplicate data from RFID data stream is an important and challenging problem. Existing Bloom Filter-based approaches for filtering duplicate RFID data streams are complex and slow as they use multiple hash functions. In this paper, we propose an approach for filtering duplicate data from RFID data streams. The proposed approach is based on modified Bloom Filter and uses only a single hash function. We performed extensive empirical study of the proposed approach and compared it against the Bloom Filter, d-Left Time Bloom Filter, and the Count Bloom Filter approaches. The results show that the proposed approach outperforms the baseline approaches in terms of false positive rate, execution time, and true positive rate.

  15. Workplace Exposure to Titanium Dioxide Nanopowder Released from a Bag Filter System

    Directory of Open Access Journals (Sweden)

    Jun Ho Ji

    2015-01-01

    Full Text Available Many researchers who use laboratory-scale synthesis systems to manufacture nanomaterials could be easily exposed to airborne nanomaterials during the research and development stage. This study used various real-time aerosol detectors to investigate the presence of nanoaerosols in a laboratory used to manufacture titanium dioxide (TiO2. The TiO2 nanopowders were produced via flame synthesis and collected by a bag filter system for subsequent harvesting. Highly concentrated nanopowders were released from the outlet of the bag filter system into the laboratory. The fractional particle collection efficiency of the bag filter system was only 20% at particle diameter of 100 nm, which is much lower than the performance of a high-efficiency particulate air (HEPA filter. Furthermore, the laboratory hood system was inadequate to fully exhaust the air discharged from the bag filter system. Unbalanced air flow rates between bag filter and laboratory hood systems could result in high exposure to nanopowder in laboratory settings. Finally, we simulated behavior of nanopowders released in the laboratory using computational fluid dynamics (CFD.

  16. Compilation of data on the release of radioactive substances in the vent air of nuclear power plants in the Federal Republic of Germany in 1975

    International Nuclear Information System (INIS)

    Winkelmann, I.; Endrulat, H.J.; Haubelt, R.; Westpfahl, U.

    1976-04-01

    The present compilation of data on the release of radioactive substances in the vent air of nuclear power plants in the FRG is a continuation of a report series on aerosol filter and iodine filter samples from the exhaust air control systems of the nuclear power plants Gundremmingen, Obrigheim, Wuergassen, Stade, Lingen and Biblis A. The reports have been issued by the Federal public health office since 1972. This report is supplemented by annual release values on radioactive noble gases, on short- and long-lived aerosols, and on gaseous 131 I, supplied by the individual nuclear power plants as in previous years on uniform questionnaires. Data on the release of tritium are also available from some nuclear power plants. (orig.) [de

  17. New iodine filter pack design

    International Nuclear Information System (INIS)

    Blackbee, B.A.

    1977-10-01

    To enable Naval Emergency Monitoring Teams to fulfil their role in the field it was necessary to locate or design a replacement filter pack for the collection of radioactive iodine air samples. Collaboration with the Berkeley Laboratories of the Central Electricity Generating Board provided the necessary starting point for a suitable type of package. Further development by NGTE (West Drayton) yielded the improved filter pack which is the subject of this memorandum. (author)

  18. Examination of quantitative accuracy of PIXE analysis for atmospheric aerosol particle samples. PIXE analysis of NIST air particulate on filter media

    International Nuclear Information System (INIS)

    Saitoh, Katsumi; Sera, Koichiro

    2005-01-01

    In order to confirm accuracy of the direct analysis of filter samples containing atmospheric aerosol particles collected on a polycarbonate membrane filter by PIXE, we carried out PIXE analysis on a National Institute of Standards and Technology (NIST, USA) air particulate on filter media (SRM 2783). For 16 elements with NIST certified values determined by PIXE analysis - Na, Mg, Al, Si, S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn and Pb - quantitative values were 80-110% relative to NIST certified values except for Na, Al, Si and Ni. Quantitative values of Na, Al and Si were 140-170% relative to NIST certified values, which were all high, and Ni was 64%. One possible reason why the quantitative values of Na, Al and Si were higher than the NIST certified values could be the difference in the X-ray spectrum analysis method used. (author)

  19. Electric air filtration: theory, laboratory studies, hardware development, and field evaluations

    International Nuclear Information System (INIS)

    Bergman, W.; Biermann, A.; Kuhl, W.

    1983-09-01

    We summarize the results of a seven-year research project for the US Department of Energy (DOE) to develop electric air filters that extend the service life of high-efficiency particulate air (HEPA) filters used in the nuclear industry. This project was unique to Lawrence Livermore National Laboratory (LLNL), and it entailed comprehensive theory, laboratory studies, and hardware development. We present our work in three major areas: (1) theory of and instrumentation for filter test methods, (2) theoretical and laboratory studies of electric air filters, and (3) development and evaluation of eight experimental electric air filters

  20. Carbon filter property detection with thermal neutron technique

    International Nuclear Information System (INIS)

    Deng Zhongbo; Han Jun; Li Wenjie

    2003-01-01

    The paper discussed the mechanism that the antigas property of the carbon filter will decrease because of its carbon bed absorbing water from the air while the carbon filter is being stored, and introduced the principle and method of detection the amount of water absorption with thermal neutron technique. Because some certain relation between the antigas property of the carbon filter and the amount of water absorption exists, the decrease degree of the carbon filter antigas property can be estimated through the amount of water absorption, offering a practicable facility technical pathway to quickly non-destructively detect the carbon filter antigas property

  1. An innovative system for supplying air and fuel mixture to a combustion chamber of an engine

    Science.gov (United States)

    Saikumar, G. R. Bharath

    2018-04-01

    Conventional carburetors are being used since decades to ensure that the desired ratio of air and fuel enters the combustion chamber for combustion for the purpose of generating power in an Spark Ignition(SI) internal combustion engine. However to increase the efficiency, the carburetor system is gradually being replaced by fuel injection systems. Fuel injection systems use injectors to supply pressurized fuel into the combustion chamber. Owing to the high initial and maintenance cost, carburetors are still ruling in the low cost vehicle domain. An innovative concept is conceived, which is an alternative method to the carburetor system to supply the air and fuel mixture to a combustion chamber of an engine. This system comprises of an inner hollow cylinder with minute holes drilled along its length with an outer cylinder capable of sliding along its length or its longitudinal axis. This system is placed in the venturi instead of the conventional carburetor system. Fuel enters from the bottom inlet of the inner cylinder and flows out through the holes provided along its length. The fuel flow from the inner cylinder is dependent on the size and the number of holes exposed at that instance by the sliding outer cylinder which in turn is connected to the throttle or accelerator.

  2. Impact Analysis of Air Pollutant Emission Policies on Thermal Coal Supply Chain Enterprises in China

    Directory of Open Access Journals (Sweden)

    Xiaopeng Guo

    2014-12-01

    Full Text Available Spurred by the increasingly serious air pollution problem, the Chinese government has launched a series of policies to put forward specific measures of power structure adjustment and the control objectives of air pollution and coal consumption. Other policies pointed out that the coal resources regional blockades will be broken by improving transportation networks and constructing new logistics nodes. Thermal power takes the largest part of China’s total installed power generation capacity, so these policies will undoubtedly impact thermal coal supply chain member enterprises. Based on the actual situation in China, this paper figures out how the member enterprises adjust their business decisions to satisfy the requirements of air pollution prevention and control policies by establishing system dynamic models of policy impact transfer. These dynamic analyses can help coal enterprises and thermal power enterprises do strategic environmental assessments and find directions of sustainable development. Furthermore, the policy simulated results of this paper provide the Chinese government with suggestions for policy-making to make sure that the energy conservation and emission reduction policies and sustainable energy policies can work more efficiently.

  3. Development of a model for activated sludge aeration systems: linking air supply, distribution, and demand.

    Science.gov (United States)

    Schraa, Oliver; Rieger, Leiv; Alex, Jens

    2017-02-01

    During the design of a water resource recovery facility, it is becoming industry practice to use simulation software to assist with process design. Aeration is one of the key components of the activated sludge process, and is one of the most important aspects of modelling wastewater treatment systems. However, aeration systems are typically not modelled in detail in most wastewater treatment process modelling studies. A comprehensive dynamic aeration system model has been developed that captures both air supply and demand. The model includes sub-models for blowers, pipes, fittings, and valves. An extended diffuser model predicts both oxygen transfer efficiency within an aeration basin and pressure drop across the diffusers. The aeration system model allows engineers to analyse aeration systems as a whole to determine biological air requirements, blower performance, air distribution, control valve impacts, controller design and tuning, and energy costs. This enables engineers to trouble-shoot the entire aeration system including process, equipment and controls. It also allows much more realistic design of these highly complex systems.

  4. Mediterranean Region proficiency test on the determination of radionuclides in air filters. IAEA-CU--2008-02

    International Nuclear Information System (INIS)

    2009-01-01

    The IAEA helps the Member States laboratories to maintain their readiness and improving the quality of the analytical results by producing reference materials, by development of standardized methods for sample collection and analysis, and by conducting interlaboratory comparisons and proficiency tests as a tool for external quality control of analytical results. The Chemistry Unit of the Physics, Chemistry and Instrumentation Laboratory in the International Atomic Energy Agency's Seibersdorf Laboratories in Austria, has the programmatic responsibility to support global radionuclide measurement systems. To fulfil this obligation and ensure a reliable worldwide, rapid and consistent response, the Chemistry Unit organises interlaboratory studies and proficiency tests. The activity concentration of radionuclides in the air is a critical factor in assessing the air quality and the potential impact of possible pollutants. Air is in fact one of the main pathways for human exposure to pollutants. Radioactivity may be present in the atmosphere due to natural processes; intentional (low level) anthropogenic release; or as a consequence of nuclear or radiological incident. Within the frame of the IAEA Technical Cooperation project RER/8/009 'Air Pollution Monitoring in the Mediterranean Region', several Member States expressed their interest in establishing close cooperation among Mediterranean countries in the field of harmonization of air pollution monitoring systems and creation of a common database, since they share geographical position and mutual interest in the environmental conditions of the Mediterranean region. Such cooperation will also promote and enhance the exchange of experience/information. This report summarizes the results of the IAEA-CU-2008-02 Mediterranean Region proficiency test on the determination of radionuclides in air filters

  5. Computer Vision Tracking Using Particle Filters for 3D Position Estimation

    Science.gov (United States)

    2014-03-27

    List of Acronyms Acronym Definition AFIT Air Force Institute of Technology ASIR Auxiliary Sampling Importance Re-sampling BPF Bootstrap Particle Filter...Auxiliary Sampling Importance Re-sampling ( ASIR ) filter, and Regularized Particle Filter (RPF), also seek to eliminate weight collapse through a variety

  6. First Study Of HEPA Filter Prototype Performance To Control The Airborne Pollution

    International Nuclear Information System (INIS)

    Soetomo; Suwarno

    2000-01-01

    This paper will report the efficiency test result of the filtration tool prototype of High Efficiency Particulate Air (HEPA filter) for low temperature, to control the airborne pollution of aerosol particle of solid and liquid. The prototype design of HEPA filter was based on the characteristic data of filter material (fibrous diameter, density, filter thickness), flow rate of air and first pressure drop. From the result of laboratory scale test, using DOP/PSL aerosol with 0,3 mum diameter and the flow rate of 3,78 m exp.3/min, was obtained filtration efficiency revolve between 89,90 and 99,94 % for the filter prototype of A, B, C, and D. the efficiency estimation of theory with filtration programme and the experiment was different amount 1 %. The value of the prototype efficiency of D filter was not far different with AAF-USA filter and its price is cheaper 30 % than the price of AAF-USA filter

  7. Study of an electrical heating system with ductless air supply and shape-stabilized PCM for thermal storage

    International Nuclear Information System (INIS)

    Lin, Kunping; Zhang, Yinping; Di, Hongfa; Yang, Rui

    2007-01-01

    A kind of electrical floor heating system with a shape-stabilized phase change material (PCM) which has been studied at Tsinghua University in our previous studies, can provide space heating during the whole day and can be controlled conventionally. However, this is not suitable for office buildings where no space heating is needed at night. The effective control is very important for the heating system in such buildings. In this paper, we studied a kind of new electrical floor heating system with ductless air supply and shape-stabilized PCM for thermal storage in order to overcome the shortcomings of the passive under-floor electric heating system with thermal storage. In this paper, we investigated its thermal performance by experiments and simulation, calculated the effects of various factors and discussed the application feasibility in different climate regions. The results show that the total electrical energy consumption was shifted from the peak period to the off-peak period, which would provide significant economic benefits because of the different day and night electricity tariffs. The system can be designed by choosing PCM with proper melting temperature and be controlled by varying velocity of air supply in different conditions

  8. Contribution of 222Rn in domestic water supplies to 222Rn in indoor air in Colorado homes

    International Nuclear Information System (INIS)

    Lawrence, E.P.; Wanty, R.B.; Nyberg, P.

    1992-01-01

    The contribution of 222Rn from domestic water wells to indoor air was investigated in a study of 28 houses near Conifer, CO. Air concentrations determined by alpha-track detectors (ATDs) and continuous radon monitors were compared with the predictions of a single-cell model. In many of the houses, the water supply was shown to contribute significantly to levels of indoor 222Rn. The data from the ATD study were augmented with a continuous monitoring study of a house near Lyons, CO. The well water in that house has the highest known concentration of 222Rn in water yet reported (93 MBq m-3). The temporal pattern in the indoor 222Rn concentration corresponds to water-use records. In general, it is difficult to quantify the proportion of indoor radon attributable to water use. Several lines of evidence suggest that the single-cell model underestimates this proportion. Continuous-monitoring data, although useful, are impractical due to the cost of the equipment. We propose a protocol for 222Rn measurement based on three simultaneous integrating radon detectors that may help estimate the proportion of indoor 222Rn derived from the water supply

  9. Contribution to the improvement of the sodium chloride air filter test method

    International Nuclear Information System (INIS)

    Delhaye, J.; Michel, J.

    1977-01-01

    The essential feature of the test method initially developed by the Porton Down Chemical Defence Establishment and modified subsequently by the Atomic Energy Research Establishment at Harwell have been adopted for the testing of high efficiency filters by the European Committee of Manufacturers of Equipment for Air Treatment (EUROVENT). The method has also been studied in the context of the ISO. The Heating and Ventilation Industries, Technical Centre (CETIAT), which uses this method, has drawn attention to a number of imperfections which affect reproductibility. It proposes changes which should have the effect of making the method reproducible not only in a given laboratory but also from one laboratory to another. It will then be possible to carry out studies to compare this method with other similar ones, in particular the fluorescin method (Standard NF X 44 011). The work carried out by CETIAT was concerned mainly with the following: aerosol generation, the velocity spectra in sampling sections, photometer calibration

  10. Apparatus for Removing Remaining Adhesives of Filter

    International Nuclear Information System (INIS)

    Kang, Il Sik; Kim, Tae Kuk; Hong, Dae Seok; Ji, Young Yong; Ryu, Woo Seog

    2010-01-01

    A Large amount of ventilation filter was used at radiation areas not only in nuclear power plants but also in nuclear facilities. These spent ventilation filters are generated as radioactive waste and composed of a steel frame, glass fiber media and aluminum separator. When treated, the spent filter is separated into filter media for air purification and frame. After separation, while the filter media is collected using steel drum for reducing internal exposure, the filter frame is treated further to remove adhesives for recycling the frame as many as possible in order to reduce waste and cost and improve working conditions. Usually, the adhesives are separated from the filter frame manually. As a result, a lot of time and labor is required. So, the objective of this study is to develop a motor-driven apparatus for removing adhesives efficiently

  11. Methods for in-place testing of HEPA and iodine filters used in nuclear power plants

    International Nuclear Information System (INIS)

    Holmberg, R.; Laine, J.

    1978-04-01

    The purpose of this work was a general investigation of existing in-place test methods and to build an equipment for in-place testing of HEPA and iodine sorption filters. In this work the discussion is limited to methods used in in-place testing of HEPA and iodine sorption filters used in light-water-cooled reactor plants. Dealy systems, built for the separation of noble gases, and testing of them is not discussed in the work. Contaminants present in the air of a reactor containment can roughly be diveded into three groups: aerosols, reactive gases, and noble gases. The aerosols are filtered with HEPA (High Efficiency Particulate Air) filters. The most important reactive gases are molecular iodine and its two compounds: hydrogen iodide and methyl iodide. Of gases to be removed by the filters methyl iodide is the gas most difficult to remove especially at high relative humidities. Impregnated activated charcoal is generally used as sorption material in the iodine filters. Experience gained from the use of nuclear power plants proves that the function of high efficiency air filter systems can not be considered safe until this is proved by in-place tests. In-place tests in use are basically equal. A known test agent is injected upstream of the filter to be tested. The efficiency is calculated from air samples taken from both sides of the filter. (author)

  12. Air-supplied pinhole discharge in aqueous solution for the inactivation of Escherichia coli

    Science.gov (United States)

    Suganuma, Ryota; Yasuoka, Koichi

    2018-04-01

    An air-supplied pinhole discharge in aqueous solution has been developed to provide a short-lived and odorless bactericide to replace current conventional disinfectants such as O3, ClO-, HClO, and ClO2. The pinhole discharge that was initiated inside a water bubble generated hydrogen peroxide (H2O2) and nitrous acid (HNO2) simultaneously. The concentrations of H2O2, HNO2, and HNO3 were 16.3, 13.9, and 17.4 mg/L, respectively when flow rates of NaCl solution and air were 72 and 12.5 mL/min, respectively. The pH value of the solution was 3.87, and HO2 radicals were generated from the reaction of H2O2 with HNO2. The efficacy of sterilization of discharge-treated water was evaluated by changing the acetic solutions. A 4-orders-of-magnitude decrease in Escherichia coli survival rate was observed after treatment with a sodium citrate solution of pH 3.2 for 60 s.

  13. Effects of ERV Filter Degradation on Indoor CO2 Levels of a Classroom

    Directory of Open Access Journals (Sweden)

    Jae-Sol Choi

    2018-04-01

    Full Text Available Energy recovery ventilators (ERVs are widely used to reduce energy losses caused by ventilation and improve indoor air quality for recently-constructed buildings. It is important for spaces with high occupancy density and longer residence times, such as classrooms. In classrooms, the ERV size is typically estimated by the target number of students in the design phase, but the design air volume flow rates (m3/h of the ERV can decrease over time owing to filter degradation such as increased dust loading. In this study, field tests are conducted in a classroom to investigate filter degradation through a visual inspection and by measuring the air volume flow rates at the diffusers connected to the ERV. In addition, variations in carbon dioxide (CO2 concentrations are also measured to verify the effects of filter degradation on the indoor CO2 levels over the entire test period, which includes filter replacement, as well. As the tests are conducted during classes, several adjusting methodologies are proposed to match the different test conditions. The results show that the total air volume flow rate of the ERV increases after the filter replacement (546 to 766 m3/h, but it again decreases as time elapses (659 m3/h. Accordingly, the indoor CO2 concentration decreases after the filter replacement by more than 300 ppm (1404 to 1085 ppm, clearly showing the effect of filter degradation. However, this CO2 concentration remains similar for four months after the replacement, and the total air volume rate decreases again. An interpretation is made using computational fluid dynamics analysis that the measured CO2 concentrations are affected by airflow patterns. The airflow in the cooling system may dilute CO2 concentrations at the measuring location. Thus, periodic filter replacement and management are important to ensure the desired ERV air volume rates and consequently the desired indoor CO2 concentrations.

  14. Methyl iodide trapping efficiency of aged charcoal samples from Bruce-A emergency filtered air discharge systems

    International Nuclear Information System (INIS)

    Wren, J.C.; Moore, C.J.; Rasmussenn, M.T.; Weaver, K.R.

    1999-01-01

    Charcoal filters are installed in the emergency filtered air discharge system (EFADS) of multiunit stations to control the release of airborne radioiodine in the event of a reactor accident. These filters use highly activated charcoal impregnated with triethylenediamine (TEDA). The TEDA-impregnated charcoal is highly efficient in removing radioiodine from flowing airstreams. The iodine-removal efficiency of the charcoal is presumed to deteriorate slowly with age, but current knowledge of this effect is insufficient to predict with confidence the performance of aged charcoal following an accident. Experiments were performed to determine the methyl iodide removal efficiency of aged charcoal samples taken from the EFADS of Ontario Hydro's Bruce-A nuclear generating station. The charcoal had been in service for ∼4 yr. The adsorption rate constant and capacity were measured under post-loss-of-coolant accident conditions to determine the efficiency of the aged charcoal. The adsorption rate constants of the aged charcoal samples were observed to be extremely high, yielding a decontamination factor (DF) for a 20-cm-deep bed of the aged charcoal >1 X 10 15 . The results show that essentially no CH 3 I would escape from a 20-cm-deep bed of the aged charcoal and that the requirement for a DF of 1000 for organic iodides in the EFADS filters would be exceeded by a tremendous margin. With such high DFs, the release of iodine from a 20-cm-deep bed would be virtually impossible to detect. The adsorption capacities observed for the aged charcoal samples approach the theoretical chemisorption capacity of 5 wt% TEDA charcoal, indicating that aging in the EFADS for 4 yr has had a negligible impact on the adsorption capacity. The results indicate that the short- and long-term performances of the aged charcoal in the EFADS of Bruce-A following an accident would still far exceed performance requirements. (author)

  15. Particle size for greatest penetration of HEPA filters - and their true efficiency

    International Nuclear Information System (INIS)

    da Roza, R.A.

    1982-01-01

    The particle size that most greatly penetrates a filter is a function of filter media construction, aerosol density, and air velocity. In this paper the published results of several experiments are compared with a modern filtration theory that predicts single-fiber efficiency and the particle size of maximum penetration. For high-efficiency particulate air (HEPA) filters used under design conditions this size is calculated to be 0.21 μm diam. This is in good agreement with the experimental data. The penetration at 0.21 μm is calculated to be seven times greater than at the 0.3 μm used for testing HEPA filters. Several mechanisms by which filters may have a lower efficiency in use than when tested are discussed

  16. Laboratory measurement of secondary pollutant yields from ozone reaction with HVAC filters

    International Nuclear Information System (INIS)

    Destaillats, Hugo; Chen, Wenhao; Apte, Michael; Li, Nuan; Spears, Michael; Almosni, Jeremie; Zhang, Jianshun Jensen; Fisk, William J.

    2009-01-01

    We used Proton Transfer Reaction - Mass Spectrometry (PTR-MS) and conventional sampling methods to monitor and identify trace level organic pollutants formed in heterogeneous reactions between ozone and HVAC filters in real time. Experiments were carried out using a bench-scale flow tube reactor operating with dry air and humidified air (50% RH), at realistically high ozone concentrations (150 ppbv). We explored different filter media (i.e., fiberglass and cotton/polyester blends) and different particle loadings (i.e., clean filter and filters loaded with particles for 3 months at the Lawrence Berkeley National Laboratory and the Port of Oakland, CA). Detailed emission dynamics of very low levels of certain organic pollutants from filter media upon ozone exposure in the presence of moisture have been obtained and analyzed.

  17. Klystron bias power supplies for Indus-2 synchrotron radiation source

    International Nuclear Information System (INIS)

    Badapanda, M.K.; Hannurkar, P.R.

    2008-01-01

    The functioning of an alternating current (AC) voltage regulator based high voltage direct current (HVDC) power supplies with better input and output performances has been presented in this paper. The authors have incorporated a 3-phase series limiting inductor, along with detuned passive filter in each power supply, to take care of line harmonics and the input power factor (IPF), which is simple, cost effective, reliable and provides input performance matching that of an equivalent active filter. Such arrangement has special significance for controlled HVDC power supplies supplying to fixed load but operated from widely varying input voltages. It achieves line voltage total harmonic distortion (THD) below 4% and IPF better than 0.97, for 415 V - 30% to 415 V + 10% variations in 3-phase input voltages. A properly designed crowbar, along with suitable limiting elements, is incorporated in each power supply and stringent wire survivability tests were carried out to limit klystron fault energy below 10 Joules. Several simulated waveforms and experiment results are also presented. (author)

  18. Electricity supply. Older plants' impact on reliability and air quality

    International Nuclear Information System (INIS)

    England-Joseph, Judy A.; Adams, Charles M.; Wood, David G.; Feehan, Daniel J.; Veal, Howard F.; Skeen, John H. III; Koenigs, Melvin J.; Lichtenfeld, David I.; Seretakis, Pauline J.

    1990-09-01

    Life extension of fossil fuel plants is a relatively recent phenomenon; thus, utilities have little experience to demonstrate the longer-term operating reliability of plants with an extended service life. While utility industry officials and government and industry studies express optimism that these plants will continue to operate reliably, the officials and the studies also caution that it is too soon to determine how pursuing life extension will affect the reliability of the nation's electricity supply. According to DOE, the number of fossil fuel generating units' 30 years old or older is expected to increase from about 2,500 in 1989 to roughly 3,700 in 1998, increasing such plants' share of overall generating capacity from 13 percent in 1989 to 27 percent in 1998. EPA estimates that with existing air quality requirements, fossil fuel plant emissions will increase steadily during the coming decade. Proposed acid rain control legislation, which would affect many plants that may have their service life extended, would require utilities to significantly reduce emissions by the year 2000 but would allow utilities flexibility in deciding how and where to achieve the reductions. If such legislation is enacted, utilities generally are expected to find reducing emissions from existing plants more cost-effective than replacing them and to continue extending plants' service life. Officials of DOE and utility organizations expressed concern, however, that EPA could decide, as it did for one plant in 1988, that alterations made in extending the service life of plants exempted from the Clean Air Act would result in increased emissions and thus cause the altered plants to lose their exemption. According to the officials, the additional costs of achieving the Clean Air Act's standards could discourage some life extension projects. However, such decisions by EPA could also reduce the nation's total power plant emissions by eliminating an existing incentive to retain exempt

  19. High efficiency cabin air filter in vehicles reduces drivers' roadway particulate matter exposures and associated lipid peroxidation.

    Science.gov (United States)

    Yu, Nu; Shu, Shi; Lin, Yan; She, Jianwen; Ip, Ho Sai Simon; Qiu, Xinghua; Zhu, Yifang

    2017-01-01

    Commuters who spend long hours on roads are exposed to high levels of traffic related air pollutants (TRAPs). Despite some well-known multiple adverse effects of TRAPs on human health, limited studies have focused on mitigation strategies to reduce these effects. In this study, we measured fine particulate matter (PM2.5) and ultrafine particle (UFP) concentrations inside and outside 17 taxis simultaneously while they were driven on roadways. The drivers' urinary monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and malondialdehyde (MDA) concentrations just before and right after the driving tests were also determined. Data were collected under three driving conditions (i.e. no mitigation (NM), window closed (WC), and window closed plus using high efficiency cabin air filters (WC+HECA)) for each taxi and driver. The results show that, compared to NM, the WC+HECA reduced in-cabin PM2.5 and UFP concentrations, by 37% and 47% respectively (p health.

  20. High Efficiency, Transparent, Reusable, and Active PM2.5 Filters by Hierarchical Ag Nanowire Percolation Network.

    Science.gov (United States)

    Jeong, Seongmin; Cho, Hyunmin; Han, Seonggeun; Won, Phillip; Lee, Habeom; Hong, Sukjoon; Yeo, Junyeob; Kwon, Jinhyeong; Ko, Seung Hwan

    2017-07-12

    Air quality has become a major public health issue in Asia including China, Korea, and India. Particulate matters are the major concern in air quality. We present the first environmental application demonstration of Ag nanowire percolation network for a novel, electrical type transparent, reusable, and active PM2.5 air filter although the Ag nanowire percolation network has been studied as a very promising transparent conductor in optoelectronics. Compared with previous particulate matter air filter study using relatively weaker short-range intermolecular force in polar polymeric nanofiber, Ag nanowire percolation network filters use stronger long-range electrostatic force to capture PM2.5, and they are highly efficient (>99.99%), transparent, working on an active mode, low power consumption, antibacterial, and reusable after simple washing. The proposed new particulate matter filter can be applied for a highly efficient, reusable, active and energy efficient filter for wearable electronics application.

  1. VHF/UHF filters and multicouplers application of air resonators

    CERN Document Server

    Piette, Bernard

    2013-01-01

    This book describes the various devices used in radio communication and broadcasting to achieve high selectivity filtering and coupling. After providing a background in the basics of microwave theory and more detailed material - including a special chapter on precision and errors in measurement - the reader will find detailed descriptions, manufacturing processes, and, for the most useful instances, a number of worked-through formulas, which will allow engineers and technicians to design circuits or components for filtering or coupling applications. Content is covered in this format across a b

  2. 1000-kVA arc power supply

    International Nuclear Information System (INIS)

    Wright, R.E.; Barber, G.C.; Ponte, N.S.

    1979-01-01

    Because of ever-increasing power demands for the development of the Oak Ridge duoPIGatron ion source, a continuous-duty arc power supply was constructed for the Medium Energy Test Facility (METF) to furnish power for the plasma generator of experimental ion sources. The power supply utilizes 12-pulse rectification with half-wave switching in a delta and wye full-wave bridge that may be connected in series or parallel. It will deliver 340 V dc, 2500 A to an ion source when series connected and 170 V dc, 5000 A when paralleled connected. Silicon-controlled rectifiers (SCR) in each rectifier bridge can be switched for pulses as short as 10 ms through continuous duty. The filter section that reduces the ripple in the output consists of an inductor-to-capacitor (L-C) filter to smooth the 720-Hz pulses. The power transformer serves as an isolation transformer allowing the secondary to be elevated to the accelerating potential of the ion source. The dc output level is controlled with a 1000-kVA auto transformer connected to the primary of the power transformer. All elevated voltages and currents are monitored at ground potential with an optical telemetry system. This paper describes the power supply in detail, including block diagrams, component specifications, and waveforms when supplying power to an ion source

  3. Fungal colonization of air-conditioning systems

    Directory of Open Access Journals (Sweden)

    Ljaljević-Grbić Milica

    2008-01-01

    Full Text Available Fungi have been implicated as quantitatively the most important bioaerosol component of indoor air associated with contaminated air-conditioning systems. rarely, indoor fungi may cause human infections, but more commonly allergenic responses ranging from pneumonitis to asthma-like symptoms. From all air conditioner filters analyzed, 16 fungal taxa were isolated and identified. Aspergillus fumigatus causes more lethal infections worldwide than any other mold. Air-conditioning filters that adsorb moisture and volatile organics appear to provide suitable substrates for fungal colonization. It is important to stress that fungal colonization of air-conditioning systems should not be ignored, especially in hospital environments.

  4. Study on the Metal Fiber Filter Modeling for Capturing Radioactive Aerosol

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seunguk; Lee, Chanhyun; Park, Minchan; Lee, Jaekeun [EcoEnergy Research Institute, Busan (Korea, Republic of)

    2015-05-15

    The components of air cleaning system are demisters to remove entrained moisture, pre-filters to remove the bulk of the particulate matter, high efficiency particulate air (HEPA) filters, iodine absorbers(generally, activated carbon) and HEPA filters after the absorbers for redundancy and collection of carbon fines. The HEPA filters are most important components to prevent radioactive aerosols from being released to control room and adjacent environment. The Conventional HEPA filter has pleated media for low pressure drop. Consequently, the filters must provide high collection efficiency as well as low pressure drop. Unfortunately, conventional HEPA filters are made of glass fiber and polyester, and pose disposal issues since they cannot be recycled. In fact, 31,055 HEPA filters used in nuclear facilities in the U.S are annually disposed. The Analyses at face velocities 1cm/s and 10cm/s are also carried out, and they also show R2 value of 0.995. However, since official HEPA filter standards are established at face velocity of 5cm/s, this value will be used in further analysis. From the comparative studies carried out at different filter thickness and face velocities, a good correlation is found between the model and the experiment.

  5. Effect of humidity and particle hygroscopicity on the mass loading capacity of high efficiency particulate air (HEPA) filters

    International Nuclear Information System (INIS)

    Gupta, A.; Biswas, P.; Monson, P.R.; Novick, V.J.

    1993-01-01

    The effect of humidity, particle hygroscopicity, and size on the mass loading capacity of glass fiber high efficiency particulate air filters was studied. Above the deliquescent point, the pressure drop across the filter increased nonlinearly with areal loading density (mass collected/filtration area) of a NaCl aerosol, thus significantly reducing the mass loading capacity of the filter compared to dry hygroscopic or nonhygroscopic particle mass loadings. The specific cake resistance K 2 was computed for different test conditions and used as a measure of the mass loading capacity. K 2 was found to decrease with increasing humidity for nonhygroscopic aluminum oxide particles and for hygroscopic NaCl particles (at humidities below the deliquescent point). It is postulated that an increase in humidity leads to the formation of a more open particulate cake which lowers the pressure drop for a given mass loading. A formula for predicting K 2 for lognormally distributed aerosols (parameters obtained from impactor data) was derived. The resistance factor, R, calculated using this formula was compared to the theoretical R calculated using the Rudnick-Happel expression. For the nonhygroscopic aluminum oxide, the agreement was good but for the hygroscopic sodium chloride, due to large variation in the cake porosity estimates, the agreement was poor. 17 refs., 6 figs., 3 tabs

  6. Bag filters

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, M; Komeda, I; Takizaki, K

    1982-01-01

    Bag filters are widely used throughout the cement industry for recovering raw materials and products and for improving the environment. Their general mechanism, performance and advantages are shown in a classification table, and there are comparisons and explanations. The outer and inner sectional construction of the Shinto ultra-jet collector for pulverized coal is illustrated and there are detailed descriptions of dust cloud prevention, of measures used against possible sources of ignition, of oxygen supply and of other topics. Finally, explanations are given of matters that require careful and comprehensive study when selecting equipment.

  7. Determination of HEPA Filter Efficiency With Diocthyl Pthalate Aerosol

    International Nuclear Information System (INIS)

    Bunawas; Ruslanto, P O; Suhariyono, G

    1996-01-01

    Ultrafine aerosol filtration by HEPA (High Efficiency Particulate Air) filter has been determinated experimentally, based on the measurement of monodisperse Diocthyl Pthalate (DOP) aerosol concentration before and after passing the test filter. Using this technique, filter efficiency can be determined as a function of aerosol diameter with range from 0.017 to 0.747 um. The average efficiencies for Whatman -41 ; Whatman -42 and Whatman GF/A filters were 56.14 %; 95,74 %; and 99.65 % respectively. Gelman A Fiber Glass and Whatman membrane filter have fulfilled criterion as HEPA filter according to standard of IAEA, because of their minimum effiency of 99.90 %

  8. Criteria for calculating the efficiency of HEPA filters during and after design basis accidents

    International Nuclear Information System (INIS)

    Bergman, W.; First, M.W.; Anderson, W.L.; Gilbert, H.; Jacox, J.W.

    1994-12-01

    We have reviewed the literature on the performance of high efficiency particulate air (HEPA) filters under normal and abnormal conditions to establish criteria for calculating the efficiency of HEPA filters in a DOE nonreactor nuclear facility during and after a Design Basis Accident (DBA). The literature review included the performance of new filters and parameters that may cause deterioration in the filter performance such as filter age, radiation, corrosive chemicals, seismic and rough handling, high temperature, moisture, particle clogging, high air flow and pressure pulses. The deterioration of the filter efficiency depends on the exposure parameters; in severe exposure conditions the filter will be structurally damaged and have a residual efficiency of 0%. Despite the many studies on HEPA filter performance under adverse conditions, there are large gaps and limitations in the data that introduce significant error in the estimates of HEPA filter efficiencies under DBA conditions. Because of this limitation, conservative values of filter efficiency were chosen when there was insufficient data

  9. 42 CFR 84.1151 - DOP filter test; respirators designed as respiratory protection against dusts, fumes, and mists...

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false DOP filter test; respirators designed as... filter test; respirators designed as respiratory protection against dusts, fumes, and mists having an air...) All single air-purifying respirator filter units will be tested in an atmosphere concentration of 100...

  10. Ripple characteristic of the main ring magnet power supply for the KEK 12 GeV PS

    International Nuclear Information System (INIS)

    Sato, Hikaru; Sueno, Tuyosi; Mikawa, Katsuhiko

    1995-01-01

    First of all, general description of the main ring magnet power supply for the KEK 12 GeV PS will be described. The main power supply consists of thyristor rectifiers, DC filters, reactive power compensators, AC harmonic filters and control systems. Devices and control systems for suppressing ripple component of magnet field will be described. (author)

  11. Effect of efficient supply of pure O2 concentrated by PSA-type O2 separator on improvement of indoor air quality

    International Nuclear Information System (INIS)

    Han, Gi Bo; Jang, Jung Hee; Choi, Changsik; Lee, Tae Jin

    2016-01-01

    To minimize the cost and loss rate of energy artificial room ventilation system, the O 2 separator was suggested for the flow of the excessive ventilation amount between indoor and outdoor because the pure O 2 separated and concentrated by the O 2 separator can be supplied with the ventilation amount minimized. How the O 2 separator applies to ventilation and its operation characteristics were investigated by controlling under various conditions as well as the operation conditions optimized required for indoor air quality such as the concentration of CO 2 and O 2 . Consequently, it was known that the O 2 concentration was increased; however, the increase of the CO 2 concentration was suppressed by the sufficient supply of O 2 concentrated from the storage tank into the room despite the two persons’ breathing in the room having an inner volume of about 56m 3 . Consequently, it was concluded that the supply system of the concentrated O 2 which was stored into the tank after the production with the O 2 separator can be applied to the room ventilation system for the improvement of the indoor air quality.

  12. Large scale air monitoring: Biological indicators versus air particulate matter

    International Nuclear Information System (INIS)

    Rossbach, M.; Jayasekera, R.; Kniewald, G.

    2000-01-01

    Biological indicator organisms are widely used for monitoring and banking purposes since many years. Although the complexity of the interactions between bioorganisms and their environment is generally not easily comprehensible, environmental quality assessment using the bioindicator approach offers some convincing advantages compared to direct analysis of soil, water, or air. Direct measurement of air particulates is restricted to experienced laboratories with access to expensive sampling equipment. Additionally, the amount of material collected generally is just enough for one determination per sampling and no multidimensional characterization might be possible. Further, fluctuations in air masses have a pronounced effect on the results from air filter sampling. Combining the integrating property of bioindicators with the world wide availability and uniform matrix characteristics of air particulates as a prerequisite for global monitoring of air pollution will be discussed. A new approach for sampling urban dust using large volume filtering devices installed in air conditioners of large hotel buildings is assessed. A first experiment was initiated to collect air particulates (300 to 500 g each) from a number of hotels during a period of three to four months by successive vacuum cleaning of used inlet filters from high volume air conditioning installations reflecting average concentrations per three months in different large cities. This approach is expected to be upgraded and applied for global monitoring. Highly positive correlated elements were found in lichen such as K/S, Zn/P, the rare earth elements (REE) and a significant negative correlation between Fig and Cu was observed in these samples. The ratio of concentrations of elements in dust and Usnea spp. is highest for Cr, Zn, and Fe (400-200) and lowest for elements such as Ca, Rb, and Sr (20-10). (author)

  13. A unique power supply for the PEP II klystron at SLAC

    International Nuclear Information System (INIS)

    Cassel, R.; Nguyen, M.N.

    1997-07-01

    Each of the eight 1.2 MW RF klystrons for the PEP-II storage rings require a 2.5 MVA DC power supply of 83 Kv at 23 amps. The design for the supply was base on three factors, low cost, small size to fit existing substation pads, and good protection against damage to the klystron including klystron gun arcs. The supply uses a 12 pulse 12.5 KV primary thyristor star point controller with primary filter inductor to provide rapid voltage control, good voltage regulation, and fast turn off during klystron tube faults. The supply also uses a unique secondary rectifier, filter capacitor configuration to minimize the energy available under a klystron fault. The voltage control is from 0--90 KV with a regulation of < 0.1% and voltage ripple of < 1% P-P, (< 0.2% RMS) above 60 KV. The supply utilizes a thyristor crowbar, which under a klystron tube arc limits the energy in the klystron arc to < 5 joules. If the thyristor crowbar is disabled the energy supplied is < 40 joules into the arc. The size of the supply was reduced small enough to fit the existing PEP transformer yard pads. The cost of the power supply was < $140 per KVA

  14. A RADIANT AIR-CONDITIONING SYSTEM USING SOLAR-DRIVEN

    Directory of Open Access Journals (Sweden)

    S. A. ABDALLA

    2006-12-01

    Full Text Available Every air-conditioning system needs some fresh air to provide adequate ventilation air required to remove moisture, gases like ammonia and hydrogen sulphide, disease organisms, and heat from occupied spaces. However, natural ventilation is difficult to control because urban areas outside air is often polluted and cannot be supplied to inner spaces before being filtered. Besides the high electrical demand of refrigerant compression units used by most air-conditioning systems, and fans used to transport the cool air through the thermal distribution system draw a significant amount of electrical energy in comparison with electrical energy used by the building thermal conditioning systems. Part of this electricity heats the cooled air; thereby add to the internal thermal cooling peak load. In addition, refrigerant compression has both direct and indirect negative effects on the environment on both local and global scales. In seeking for innovative air-conditioning systems that maintain and improve indoor air quality under potentially more demanding performance criteria without increasing environmental impact, this paper presents radiant air-conditioning system which uses a solar-driven liquid desiccant evaporative cooler. The paper describes the proposed solar-driven liquid desiccant evaporative cooling system and the method used for investigating its performance in providing cold water for a radiant air-conditioning system in Khartoum (Central Sudan. The results of the investigation show that the system can operate in humid as well as dry climates and that employing such a system reduces air-conditioning peak electrical demands as compared to vapour compression systems.

  15. Pressure-controlled terahertz filter based on 1D photonic crystal with a defective semiconductor

    Science.gov (United States)

    Qinwen, XUE; Xiaohua, WANG; Chenglin, LIU; Youwen, LIU

    2018-03-01

    The tunable terahertz (THz) filter has been designed and studied, which is composed of 1D photonic crystal (PC) containing a defect layer of semiconductor GaAs. The analytical solution of 1D defective PC (1DDPC) is deduced based on the transfer matrix method, and the electromagnetic plane wave numerical simulation of this 1DDPC is performed by using the finite element method. The calculated and simulated results have confirmed that the filtering transmittance of this 1DDPC in symmetric structure of air/(Si/SiO2) N /GaAs/(SiO2/Si) N /air is far higher than in asymmetric structure of air/(Si/SiO2) N /GaAs/(Si/SiO2) N /air, where the filtering frequency can be tuned by the external pressure. It can provide a feasible route to design the external pressure-controlled THz filter based on 1DPC with a defective semiconductor.

  16. 42 CFR 84.163 - Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand...

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man test for gases and vapors; Type C supplied-air respirators, demand and pressure-demand classes; test requirements. 84.163 Section 84.163 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF...

  17. Investigation of storage-phosphor autoradiography for the rapid quantitative screening of air filters for emergency response purposes

    Science.gov (United States)

    Gallardo, Athena Marie

    Past nuclear accidents, such as Chernobyl, resulted in a large release of radionuclides into the atmosphere. Radiological assessment of the vicinity of the site of the incident is vital to assess the exposure levels and dose received by the population and workers. Therefore, it is critical to thoroughly understand the situation and risks associated with a particular event in a timely manner in order to properly manage the event. Current atmospheric radiological assessments of alpha emitting radioisotopes include acquiring large quantities of air samples, chemical separation of radionuclides, sample mounting, counting through alpha spectrometry, and analysis of the data. The existing methodology is effective, but time consuming and labor intensive. Autoradiography, and the properties of phosphor imaging films, may be used as an additional technique to facilitate and expedite the alpha analysis process in these types of situations. Although autoradiography is not as sensitive to alpha radiation as alpha spectrometry, autoradiography may benefit alpha analysis by providing information about the activity as well as the spatial distribution of radioactivity in the sample under investigation. The objective for this research was to develop an efficient method for quantification and visualization of air filter samples taken in the aftermath of a nuclear emergency through autoradiography using 241Am and 239Pu tracers. Samples containing varying activities of either 241Am or 239Pu tracers were produced through microprecipitation and assayed by alpha spectroscopy. The samples were subsequently imaged and an activity calibration curve was produced by comparing the digital light units recorded from the image to the known activity of the source. The usefulness of different phosphor screens was examined by exposing each type of film to the same standard nuclide for varying quantities of time. Unknown activity samples created through microprecipiation containing activities of

  18. Dedusting and filtering technology; Entstaubungs- und Filtertechnik

    Energy Technology Data Exchange (ETDEWEB)

    Selck, S.; Stockmann, H.W.; Both, R. [Deutsche Montan Technologie GmbH, Essen (Germany). Gas and Fire Div.

    2004-07-01

    For the further development of the filtration and dedusting technology within the last research period the new regulations in occupational hygiene concerning dust as well as ISO and EN standards have been considered. Also the new requirements concerning fire and explosion protection filter materials based in the test regulations for synthetic materials have been taken into account. The adoption of these new regulations inhibits the further use of the available high effective filter materials in underground coal mines. The development of new filter materials has been forced by the test regulations for synthetic materials, as the specific aspects of electrostatic behaviour, soot and toxic gases formed by burning of filter materials impacting the CO self rescue filters, have been taken into account. Even these requirements are partially inhibiting high filter efficiencies and air flows, all the requirements have been fulfilled on a high level on filter efficiencies matching the present state of art in occupational hygiene as reported in the Silicosis Reports Vol. 20 and 21. (orig.)

  19. Multi-stage type replacing method of iodine filter

    International Nuclear Information System (INIS)

    Kitamura, Masao; Kamiya, Kunio.

    1976-01-01

    Object: To effectively replace a filter into a removing device of radioactive impurities used in ventilation and air conditioning system or the like in an atomic power plant. Structure: A plurality of elements of a filter are arranged in series relative to fluid. In the first replacement, an ante-filter-element on inlet side of fluid is removed, and a post-filter-element is repositioned to that position of the ante-element. Then, a fresh element is newly mounted on that position of the post-element. Replacement after the second time may be effected by repeating the operation noted above. With this arrangement, the minimal value of collection efficiency at replacement of filter may be increased. (Ikeda, J.)

  20. Design of ventilation and air cleaning systems for the new Los Alamos Plutonium Facility

    International Nuclear Information System (INIS)

    Mitchell, R.; DeField, J.; Stafford, R.; McNeese, W.; Eberhardt, W.; Laushkin, N.

    1975-01-01

    The Los Alamos Scientific Laboratory's new plutonium facility will conform to AECM Appendix 6301-Part II, Section H-Minimum Design Criteria for New Plutonium Facilities. The glove box process exhaust air is filtered through three or four stages of HEPA filters. The design of this multi-stage filter installation is shown with a method of in-place testing of each stage individually. A glove box filter holder and the in-place test procedure is described. General room air from plutonium work areas is recirculated at the rate of eight air changes per hour with a 10 percent fresh air make-up. The filter plenums for the recirculated air are designed to permit in-place testing of each of the two filter stages. (U.S.)

  1. Experimental study on air cleaning effect of clean air heat pump and its impact on ventilation requirement

    DEFF Research Database (Denmark)

    Fang, Lei; Sheng, Ying; Nie, Jinzhe

    2017-01-01

    This study investigated air purification effect of a Clean-Air Heat Pump (CAHP) which combined a desiccant wheel with a heat pump for both air cleaning and HVAC of buildings. The experiment was conducted in a field lab at four different outdoor air supply rates with and without air cleaning by CAHP....... Both sensory assessments of perceived air quality and chemical measurements of TVOC concentrations were conducted for evaluating the air cleaning performance of the CAHP. The results of experiment showed that running the CAHP improved significantly perceived air quality. At 2 L/s per person of outdoor...... air supply rate with operating the CAHP, the air quality was equivalent to the value at the higher outdoor air supply rate of 10 L/s per person without running CAHP. The TVOC measurements observed over 92% of efficiency on removal of indoor air VOCs and no VOCs accumulation on the desiccant wheel...

  2. Microbial degradation of pesticides in rapid sand filters for treatment of drinking water

    DEFF Research Database (Denmark)

    Hedegaard, Mathilde Jørgensen; Albrechtsen, Hans-Jørgen

    2014-01-01

    In Denmark drinking water supply is based on groundwater which is treated by aeration followed by filtration in rapid sand filters. Unfortunately pesticide contamination of the groundwater poses a threat to the water supply, since the simple treatment process at the waterworks is not considered...... to remove pesticides from the water phase and pesticides are detected in 24% of the active Danish waterworks wells. This study aimed at investigating the potential of microbial pesticide removal in rapid sand filters for drinking water treatment. Removal of the pesticides MCPP, bentazone, glyphosate...... and the degradation compound p-nitrophenol was investigated in the rapid sand filters at Islevbro and Sjælsø waterworks plant I and II. Microcosms were set up with sand from rapid sand filters, water and an initial pesticide concentration of 0.03-0.38 μg/L. In all the investigated waterworks the concentration...

  3. An asymmetric MOSFET-C band-pass filter with on-chip charge pump auto-tuning

    International Nuclear Information System (INIS)

    Chen Fangxiong; Ma Heping; Jia Hailong; Shi Yin; Lin Min; Dai, Forster

    2009-01-01

    An asymmetric MOSFET-C band-pass filter (BPF) with on chip charge pump auto-tuning is presented. It is implemented in UMC (United Manufacturing Corporation) 0.18 μm CMOS process technology. The filter system with auto-tuning uses a master-slave technique for continuous tuning in which the charge pump outputs 2.663 V, much higher than the power supply voltage, to improve the linearity of the filter. The main filter with third order low-pass and second order high-pass properties is an asymmetric band-pass filter with bandwidth of 2.730-5.340 MHz. The in-band third order harmonic input intercept point (IIP3) is 16.621 dBm, with 50 Ω as the source impedance. The input referred noise is about 47.455 μV rms . The main filter dissipates 3.528 mW while the auto-tuning system dissipates 2.412 mW from a 1.8 V power supply. The filter with the auto-tuning system occupies 0.592 mm 2 and it can be utilized in GPS (global positioning system) and Bluetooth systems. (semiconductor integrated circuits)

  4. An asymmetric MOSFET-C band-pass filter with on-chip charge pump auto-tuning

    Energy Technology Data Exchange (ETDEWEB)

    Chen Fangxiong; Ma Heping; Jia Hailong; Shi Yin [Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China); Lin Min [Suzhou-CAS Semiconductors Integrated Technology Research Center, Suzhou 215021 (China); Dai, Forster, E-mail: fxchen@semi.ac.c [Department of Electrical and Computer Engineering, Auburn University, AL 36849 (United States)

    2009-08-15

    An asymmetric MOSFET-C band-pass filter (BPF) with on chip charge pump auto-tuning is presented. It is implemented in UMC (United Manufacturing Corporation) 0.18 {mu}m CMOS process technology. The filter system with auto-tuning uses a master-slave technique for continuous tuning in which the charge pump outputs 2.663 V, much higher than the power supply voltage, to improve the linearity of the filter. The main filter with third order low-pass and second order high-pass properties is an asymmetric band-pass filter with bandwidth of 2.730-5.340 MHz. The in-band third order harmonic input intercept point (IIP3) is 16.621 dBm, with 50 {Omega} as the source impedance. The input referred noise is about 47.455 {mu}V{sub rms}. The main filter dissipates 3.528 mW while the auto-tuning system dissipates 2.412 mW from a 1.8 V power supply. The filter with the auto-tuning system occupies 0.592 mm{sup 2} and it can be utilized in GPS (global positioning system) and Bluetooth systems. (semiconductor integrated circuits)

  5. Investigation of efficiency of air cleaning from acetone using a segmental construction biofilter

    Directory of Open Access Journals (Sweden)

    Denas Bacevičius

    2015-10-01

    Full Text Available Volatile organic compounds, e. g. acetone, have a direct impact on climate change, decrease of ozone in the air, and on the growth of greenhouse effect. One of the most popular air purifying methods from VOC is a biological air cleaning. Experimental investigations were conducted to determine the efficiency of the new structure of biofilter with polypropylene plates segments. During the investigations the efficiency of segmental construction biofilter of air purification at different initial concentrations of pollutants was determined. Different concentrations of pollutants were estimated during the acetone dilution with water. During the tests the efficiency of biofilter air purification from acetone vapor and its change under different concentrations of vapors was set. Based on test results, the maximum efficiency of biofilter air purification was up to 93%. Studies have shown that increasing the allowable pollutant concentration, the efficiency of air purification unit decreases. Increasing the concentration of supplied acetone vapor into the biofilter from 232 to 701 mg/m3, cleaning efficiency decreased from 92.8 to 82.3%. Since microorganisms fail to oxidize organic compounds, the filter works better at lower initial concentrations of pollutants.

  6. Filtered region of interest cone-beam rotational angiography

    International Nuclear Information System (INIS)

    Schafer, Sebastian; Noeel, Peter B.; Walczak, Alan M.; Hoffmann, Kenneth R.

    2010-01-01

    Purpose: Cone-beam rotational angiography (CBRA) is widely used in the modern clinical settings. In a number of procedures, the area of interest is often considerably smaller than the field of view (FOV) of the detector, subjecting the patient to potentially unnecessary x-ray dose. The authors therefore propose a filter-based method to reduce the dose in the regions of low interest, while supplying high image quality in the region of interest (ROI). Methods: For such procedures, the authors propose a method of filtered region of interest (FROI)-CBRA. In the authors' approach, a gadolinium filter with a circular central opening is placed into the x-ray beam during image acquisition. The central region is imaged with high contrast, while peripheral regions are subjected to a substantial lower intensity and dose through beam filtering. The resulting images contain a high contrast/intensity ROI, as well as a low contrast/intensity peripheral region, and a transition region in between. To equalize the two regions' intensities, the first projection of the acquisition is performed with and without the filter in place. The equalization relationship, based on Beer's law, is established through linear regression using corresponding filtered and nonfiltered data. The transition region is equalized based on radial profiles. Results: Evaluations in 2D and 3D show no visible difference between conventional FROI-CBRA projection images and reconstructions in the ROI. CNR evaluations show similar image quality in the ROI, with a reduced CNR in the reconstructed peripheral region. In all filtered projection images, the scatter fraction inside the ROI was reduced. Theoretical and experimental dose evaluations show a considerable dose reduction; using a ROI half the original FOV reduces the dose by 60% for the filter thickness of 1.29 mm. Conclusions: These results indicate the potential of FROI-CBRA to reduce the dose to the patient while supplying the physician with the desired

  7. Filtered region of interest cone-beam rotational angiography

    Energy Technology Data Exchange (ETDEWEB)

    Schafer, Sebastian; Noeel, Peter B.; Walczak, Alan M.; Hoffmann, Kenneth R. [Department of Mechanical Engineering, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Computer Science, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Mechanical Engineering, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Neurosurgery, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States); Department of Computer Science, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States) and Toshiba Stroke Research Center, SUNY at Buffalo, 3435 Main Street, Buffalo, New York 14214 (United States)

    2010-02-15

    Purpose: Cone-beam rotational angiography (CBRA) is widely used in the modern clinical settings. In a number of procedures, the area of interest is often considerably smaller than the field of view (FOV) of the detector, subjecting the patient to potentially unnecessary x-ray dose. The authors therefore propose a filter-based method to reduce the dose in the regions of low interest, while supplying high image quality in the region of interest (ROI). Methods: For such procedures, the authors propose a method of filtered region of interest (FROI)-CBRA. In the authors' approach, a gadolinium filter with a circular central opening is placed into the x-ray beam during image acquisition. The central region is imaged with high contrast, while peripheral regions are subjected to a substantial lower intensity and dose through beam filtering. The resulting images contain a high contrast/intensity ROI, as well as a low contrast/intensity peripheral region, and a transition region in between. To equalize the two regions' intensities, the first projection of the acquisition is performed with and without the filter in place. The equalization relationship, based on Beer's law, is established through linear regression using corresponding filtered and nonfiltered data. The transition region is equalized based on radial profiles. Results: Evaluations in 2D and 3D show no visible difference between conventional FROI-CBRA projection images and reconstructions in the ROI. CNR evaluations show similar image quality in the ROI, with a reduced CNR in the reconstructed peripheral region. In all filtered projection images, the scatter fraction inside the ROI was reduced. Theoretical and experimental dose evaluations show a considerable dose reduction; using a ROI half the original FOV reduces the dose by 60% for the filter thickness of 1.29 mm. Conclusions: These results indicate the potential of FROI-CBRA to reduce the dose to the patient while supplying the physician with

  8. The impact of portable high-efficiency particulate air filters on the incidence of invasive aspergillosis in a large acute tertiary-care hospital.

    Science.gov (United States)

    Abdul Salam, Zakir-Hussain; Karlin, Rubiyah Binte; Ling, Moi Lin; Yang, Kok Soong

    2010-05-01

    Worldwide, the frequency of invasive fungal infections has been increasing, with a corresponding increase in the numbers of high-risk patients. Exposure reduction through the use of high-efficiency particulate air (HEPA) filters has been the preferred primary preventive strategy for these high-risk patients. Although the efficiency and benefits of fixed HEPA filters is well proven, the benefits of portable HEPA filters are still inconclusive. This was a retrospective study to assess the impact of 48 portable HEPA filter units deployed in selected wards in Singapore General Hospital, an acute tertiary-care hospital in Singapore. Data were extracted between December 2005 and June 2008 on the diagnoses at discharge and microbiological and histological laboratory findings. All patients with possible, probable, or proven invasive aspergillosis (IA) were included. In wards with portable HEPA filters, the incidence rate of IA of 34.61/100,000 patient-days in the pre-installation period was reduced to 17.51/100,000 patient-days in the post-installation period (P = .01), for an incidence rate ratio of 1.98 (95% confidence interval [CI], 1.10-2.97). In wards with no HEPA filters, there was no significant change in the incidence rate during the study period. Portable HEPA filters were associated with an adjusted odds ratio of 0.49 (95% CI, 0.28-0.85; P = .01), adjusted for diagnosis and length of hospital stay. Portable HEPA filters are effective in the prevention of IA. The cost of widespread portable HEPA filtration in hospitals will be more than offset by the decreases in nosocomial infections in general and in IA in particular. Copyright (c) 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  9. Tunable double-channel filter based on two-dimensional ferroelectric photonic crystals

    International Nuclear Information System (INIS)

    Jiang, Ping; Ding, Chengyuan; Hu, Xiaoyong; Gong, Qihuang

    2007-01-01

    A tunable double-channel filter is presented, which is based on a two-dimensional nonlinear ferroelectric photonic crystal made of cerium doped barium titanate. The filtering properties of the photonic crystal filter can be tuned by adjusting the defect structure or by a pump light. The influences of the structure disorders caused by the perturbations in the radius or the position of air holes on the filtering properties are also analyzed

  10. Tunable double-channel filter based on two-dimensional ferroelectric photonic crystals

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Ping [State Key Laboratory for Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China); Ding, Chengyuan [State Key Laboratory for Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China); Hu, Xiaoyong [State Key Laboratory for Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China)]. E-mail: xiaoyonghu@pku.edu.cn; Gong, Qihuang [State Key Laboratory for Mesoscopic Physics, Department of Physics, Peking University, Beijing 100871 (China)]. E-mail: qhgong@pku.edu.cn

    2007-04-02

    A tunable double-channel filter is presented, which is based on a two-dimensional nonlinear ferroelectric photonic crystal made of cerium doped barium titanate. The filtering properties of the photonic crystal filter can be tuned by adjusting the defect structure or by a pump light. The influences of the structure disorders caused by the perturbations in the radius or the position of air holes on the filtering properties are also analyzed.

  11. A highly linear baseband Gm—C filter for WLAN application

    Science.gov (United States)

    Lijun, Yang; Zheng, Gong; Yin, Shi; Zhiming, Chen

    2011-09-01

    A low voltage, highly linear transconductan—C (Gm—C) low-pass filter for wireless local area network (WLAN) transceiver application is proposed. This transmitter (Tx) filter adopts a 9.8 MHz 3rd-order Chebyshev low pass prototype and achieves 35 dB stop-band attenuation at 30 MHz frequency. By utilizing pseudo-differential linear-region MOS transconductors, the filter IIP3 is measured to be as high as 9.5 dBm. Fabricated in a 0.35 μm standard CMOS technology, the proposed filter chip occupies a 0.41 × 0.17 mm2 die area and consumes 3.36 mA from a 3.3-V power supply.

  12. Development of exhaust air filters for reprocessing plants

    International Nuclear Information System (INIS)

    Furrer, J.; Kaempffer, R.; Jannakos, K.; Apenberg, W.

    1975-01-01

    Investigations of the iodine loading capacity of highly impregnated iodine sorption material (AC 6,120/H 1 ) for the GWA-filters (GWA: reprocessing plant for 1,500 metric tons per year of uranium) have been continued for low NO 2 -contents of the simulated dissolver offgas from GWA. When fully loading AC 6,120/H 1 , a conversion to silver iodides of Ag + of the impregnation of about 80% was reached in experiments with 1% NO 2 in the carrier gas. Despite the consumption of a substantial portion of the impregnation removal efficiencies > 99.99% were measured for a bed depth corresponding to a GWA filter stage. The test facility allowing to examine the behavior and the capacity of the AC 6,120/H 1 iodine sorption material under actual conditions at SAP Marcoule (reprocessing plant) has been completed except for installation in the reprocessing plant. (orig.) [de

  13. Research on the water hammer protection of the long distance water supply project with the combined action of the air vessel and over-pressure relief valve

    International Nuclear Information System (INIS)

    Li, D D; Jiang, J; Zhao, Z; Yi, W S; Lan, G

    2013-01-01

    We take a concrete pumping station as an example in this paper. Through the calculation of water hammer protection with a specific pumping station water supply project, and the analysis of the principle, mathematical models and boundary conditions of air vessel and over-pressure relief valve we show that the air vessel can protect the water conveyance system and reduce the transient pressure damage due to various causes. Over-pressure relief valve can effectively reduce the water hammer because the water column re-bridge suddenly stops the pump and prevents pipeline burst. The paper indicates that the combination set of air vessel and over-pressure relief valve can greatly reduce the quantity of the air valve and can eliminate the water hammer phenomenon in the pipeline system due to the vaporization and water column separation and re-bridge. The conclusion could provide a reference for the water hammer protection of long-distance water supply system

  14. Research on the water hammer protection of the long distance water supply project with the combined action of the air vessel and over-pressure relief valve

    Science.gov (United States)

    Li, D. D.; Jiang, J.; Zhao, Z.; Yi, W. S.; Lan, G.

    2013-12-01

    We take a concrete pumping station as an example in this paper. Through the calculation of water hammer protection with a specific pumping station water supply project, and the analysis of the principle, mathematical models and boundary conditions of air vessel and over-pressure relief valve we show that the air vessel can protect the water conveyance system and reduce the transient pressure damage due to various causes. Over-pressure relief valve can effectively reduce the water hammer because the water column re-bridge suddenly stops the pump and prevents pipeline burst. The paper indicates that the combination set of air vessel and over-pressure relief valve can greatly reduce the quantity of the air valve and can eliminate the water hammer phenomenon in the pipeline system due to the vaporization and water column separation and re-bridge. The conclusion could provide a reference for the water hammer protection of long-distance water supply system.

  15. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement; Medida de los descendientes del radon en aire por Espectrometria Alfa

    Energy Technology Data Exchange (ETDEWEB)

    Acena, M L; Crespo, M T

    1989-07-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs.

  16. Measuring instrument for the determination of dust concentrations. [air filter with. beta. radiometric gage

    Energy Technology Data Exchange (ETDEWEB)

    Dresia, H; Spohr, F

    1975-05-22

    The measuring instrument enables a continuous determination of the dust concentration or total dust content in gases on the basis of the radiometric mass determination of dusts. The partial current method is employed, with the gas fetched through a filter cell with a topped intake by a suction pump. A filter band to take up the dust deposit is continuously driven through the filter cell. The filter point and the measuring point with a ..beta..-radionuclide and a detector are both inside the filter cell. The filter cell is sealed all around, at the entrance and exit of the filter band. The band itself acts as a seal. The filter band also has borders strengthened with, e.g., plastic strips which engage the drive. The widths of the slits are adjustable in height.

  17. In-place HEPA filter penetration test

    International Nuclear Information System (INIS)

    Bergman, W.; Wilson, K.; Elliott, J.; Bettencourt, B.; Slawski, J.W.

    1997-01-01

    We have demonstrated the feasibility of conducting penetration tests on high efficiency particulate air (HEPA) filters as installed in nuclear ventilation systems. The in-place penetration test, which is designed to yield equivalent penetration measurements as the standard DOP efficiency test, is based on measuring the aerosol penetration of the filter installation as a function of particle size using a portable laser particle counter. This in-place penetration test is compared to the current in-place leak test using light scattering photometers for single HEPA filter installations and for HEPA filter plenums using the shroud method. Test results show the in-place penetration test is more sensitive than the in-place leak test, has a similar operating procedure, but takes longer to conduct. Additional tests are required to confirm that the in-place penetration test yields identical results as the standard dioctyl phthalate (DOP) penetration test for HEPA filters with controlled leaks in the filter and gasket and duct by-pass leaks. Further development of the procedure is also required to reduce the test time before the in- place penetration test is practical

  18. [Filtering facepieces: effect of oily aerosol load on penetration through the filtering material].

    Science.gov (United States)

    Plebani, Carmela; Listrani, S; Di Luigi, M

    2010-01-01

    Electrostatic filters are widely used in applications requiring high filtration efficiency and low pressure drop. However various studies showed that the penetration through electrostatic filters increases during exposure to an aerosol flow. This study investigates the effects of prolonged exposure to an oily aerosol on the penetration through filtering facepieces available on the market. Some samples of FFP1, FFP2 and FFP3 filtering facepieces were exposed for 8 hours consecutively to a paraffin oil polydisperse aerosol. At the end of the exposure about 830 mg of paraffin oil were deposited in the facepiece. All the examined facepieces showed penetration values that increased with paraffin oil load while pressure drop values were substantially the same before and after exposure. The measured maximum penetration values did not exceed the maximum penetration values allowed by the European technical standards, except in one case. According to the literature, 830 mg of oil load in a facepiece is not feasible in workplaces over an eight- hour shift. However, the trend of the penetration versus exposure mass suggests that if the load increases, the penetration may exceed the maximum allowed values. For comparison a mechanical filter was also studied. This showed an initial pressure drop higher than FFP2 filtering facepieces characterized by comparable penetration values. During exposure the pressure drop virtually doubled while penetration did not change. The increase in penetration with no increase in pressure drop in the analyzed facepieces indicates that it is necessary to comply with the information supplied by the manufacturer that restricts their use to a single shift.

  19. Penetration of HEPA filters by alpha recoil aerosols

    International Nuclear Information System (INIS)

    McDowell, W.J.; Seeley, F.G.; Ryan, M.T.

    1976-01-01

    The self-scattering of alpha-active substances has long been recognized and is attributed to expulsion of aggregates of atoms from the surface of alpha-active materials by alpha emission recoil energy, and perhaps to further propulsion of these aggregates by subsequent alpha recoils. Workers at the University of Lowell recently predicted that this phenomenon might affect the retention of alpha-active particulate matter by HEPA filters, and found support in experiments with 212 Pb. Tests at Oak Ridge National Laboratory have confirmed that alpha-emitting particulate matter does penetrate high-efficiency filter media, such as that used in HEPA filters, much more effectively than do non-radioactive or beta-gamma active aerosols. Filter retention efficiencies drastically lower than the 99.9 percent quoted for ordinary particulate matter were observed with 212 Pb, 253 Es, and 238 Pu sources, indicating that the phenomenon is common to all of these and probably to all alpha-emitting materials of appropriate half-life. Results with controlled air-flow through filters in series are consistent with the picture of small particles dislodged from the ''massive'' surface of an alpha-active material, and then repeatedly dislodged from positions on the filter fibers by subsequent alpha recoils. The process shows only a small dependence on the physical form of the source material. Oxide dust, nitrate salt, and plated metal all seem to generate the recoil particles effectively. The amount penetrating a series of filters depends on the total amount of activity in the source material, its specific activity, and the length of time of air flow

  20. Development of Test Protocols for International Space Station Particulate Filters

    Science.gov (United States)

    Vijayakumar, R.; Green, Robert D.; Agui, Juan H.

    2015-01-01

    Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing

  1. Performance evaluation of nuclear grade filters for the Trupact-I pressure equalization system

    International Nuclear Information System (INIS)

    Sandoval, R.P.; Joseph, B.J.

    1987-01-01

    The performance of high-efficiency-particulate-air and ultra-low- penetration-air filters subjected to extreme environments of temperature, shock, pressure, and particulate loading was evaluated in a test program at the Sandia National Laboratories. The test program was initiated to evaluate the feasibility of using commercially available nuclear-grade filters in the filtered pressure equalization system of a contact-handled transuranic waste transport system, called TRUPACT-I. The filtered pressure equalization system of TRUPACT-I assures containment of the activity within the limits permitted by federal regulations and simultaneously equalizes the pressure between the cavity of the packaging and the environment, and minimizes the buildup of radiolytically generated gases. The filters were exposed to temperatures, pressures and stresses that exceed expected environments in normal and accident conditions of transport. The performance of the test filters was determined by measuring and quantifying filter efficiency and the Darcy constant. In addition, the integrity of the filter housing was evaluated using non-destructive helium leak testing. The details of the test program and results obtained from the tests are presented in this paper

  2. Evaluation of an air drilling cuttings containment system

    Energy Technology Data Exchange (ETDEWEB)

    Westmoreland, J.

    1994-04-01

    Drilling at hazardous waste sites for environmental remediation or monitoring requires containment of all drilling fluids and cuttings to protect personnel and the environment. At many sites, air drilling techniques have advantages over other drilling methods, requiring effective filtering and containment of the return air/cuttings stream. A study of. current containment methods indicated improvements could be made in the filtering of radionuclides and volatile organic compounds, and in equipment like alarms, instrumentation or pressure safety features. Sandia National Laboratories, Dept. 61 11 Environmental Drilling Projects Group, initiated this work to address these concerns. A look at the industry showed that asbestos abatement equipment could be adapted for containment and filtration of air drilling returns. An industry manufacturer was selected to build a prototype machine. The machine was leased and put through a six-month testing and evaluation period at Sandia National Laboratories. Various materials were vacuumed and filtered with the machine during this time. In addition, it was used in an actual air drive drilling operation. Results of these tests indicate that the vacuum/filter unit will meet or exceed our drilling requirements. This vacuum/filter unit could be employed at a hazardous waste site or any site where drilling operations require cuttings and air containment.

  3. Development of a Data-Driven Predictive Model of Supply Air Temperature in an Air-Handling Unit for Conserving Energy

    Directory of Open Access Journals (Sweden)

    Goopyo Hong

    2018-02-01

    Full Text Available The purpose of this study was to develop a data-driven predictive model that can predict the supply air temperature (SAT in an air-handling unit (AHU by using a neural network. A case study was selected, and AHU operational data from December 2015 to November 2016 was collected. A data-driven predictive model was generated through an evolving process that consisted of an initial model, an optimal model, and an adaptive model. In order to develop the optimal model, input variables, the number of neurons and hidden layers, and the period of the training data set were considered. Since AHU data changes over time, an adaptive model, which has the ability to actively cope with constantly changing data, was developed. This adaptive model determined the model with the lowest mean square error (MSE of the 91 models, which had two hidden layers and sets up a 12-hour test set at every prediction. The adaptive model used recently collected data as training data and utilized the sliding window technique rather than the accumulative data method. Furthermore, additional testing was performed to validate the adaptive model using AHU data from another building. The final adaptive model predicts SAT to a root mean square error (RMSE of less than 0.6 °C.

  4. HEPA Filter Performance under Adverse Conditions

    International Nuclear Information System (INIS)

    Parsons, Michael; Hogancamp, Kristina; Alderman, Steven; Waggoner, Charles

    2007-01-01

    This study involved challenging nuclear grade high-efficiency particulate air (HEPA) filters under a variety of conditions that can arise in Department of Energy (DOE) applications such as: low or high RH, controlled and uncontrolled challenge, and filters with physically damaged media or seals (i.e., leaks). Reported findings correlate filter function as measured by traditional differential pressure techniques in comparison with simultaneous instrumental determination of up and down stream PM concentrations. Additionally, emission rates and failure signatures will be discussed for filters that have either failed or exceeded their usable lifetime. Significant findings from this effort include the use of thermocouples up and down stream of the filter housing to detect the presence of moisture. Also demonstrated in the moisture challenge series of tests is the effect of repeated wetting of the filter. This produces a phenomenon referred to as transient failure before the tensile strength of the media weakens to the point of physical failure. An evaluation of the effect of particle size distribution of the challenge aerosol on loading capacity of filters is also included. Results for soot and two size distributions of KCl are reported. Loading capacities for filters ranged from approximately 70 g of soot to nearly 900 g for the larger particle size distribution of KCl. (authors)

  5. Wien filter for a polarized ions source

    International Nuclear Information System (INIS)

    Perez A, P.I.

    1977-01-01

    In order to carry out investigation works about nuclear structure, the Nuclear Center of Mexico has an accelerator Tandem Van de Graff of 12 Mv. Now in this center there is a polarized ions source, in a setting phase, totally constructed in the workshop of the accelerator. This source, supplies an ion beam with a polarization whose propagation direction is not the adequate one for the dispersion and reaction processes wanted to be realized. A filter Wien was used to obtain the correct direction of the polarization vector. The purpose of this work is the study of the filter necessary conditions in order to reach the desirable objective. In the first part some generalities are given about: polarization phenomena, polarized ions source and description of the performance of the Wien filter. In the second part, the problem of the passage of a polarized beam through the filter is tried and solved. Finally, the design and construction of the filter is presented together with the results of the experimentation with the object to justify the suppositions which were taken into consideration in the solution of the filter problem. (author)

  6. Some observations on air filtration

    NARCIS (Netherlands)

    Kluyver, A.J.; Visser, J.

    1950-01-01

    1. A method has been developed for testing the filtration efficiency of some filter materials. For each of the materials investigated — cotton wool, stillite and carbon — a suitable filter has been devised. 2. The filtered air was analyzed as to its germ content with the aid of a set of 3 capillary

  7. Experimental analysis of indoor air quality improvement achieved by using a Clean-Air Heat Pump (CAHP) air-cleaner in a ventilation system

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Nie, Jinzhe

    2017-01-01

    This study investigated the air purification effect of a Clean-Air Heat Pump (CAHP) air-cleaner which combined a silica gel rotor with a heat pump to achieve air cleaning, heating and ventilation in buildings. The experiments were conducted in a field laboratory and compared a low outdoor air...... supply rate with CAHP air purification of recirculated air with three different outdoor air supply rates without recirculation or air cleaning. Sensory assessments of perceived air quality and chemical measurements of TVOC concentration were used to evaluate the air-cleaning performance of the CAHP....... The results of the experiment showed that the operation of the CAHP significantly improved the perceived air quality in a room polluted by both human bio-effluents and building materials. At the outdoor airflow rate of 2 L/s per person, the indoor air quality with CAHP was equivalent to what was achieved...

  8. PIXE analysis of atmospheric particulate matter in glas fibre filters

    International Nuclear Information System (INIS)

    Tabacniks, M.H.; Orsini, C.Q.; Maenhaut, W.

    1993-01-01

    A 3-step extraction procedure was developed to allow particle-induced X-ray emission (PIXE) analysis of particulate matter in normal glass fibre filter samples. The detection limits, expressed in ng/m 3 of air, for the filter extracts were 5 to 30 times lower than those achieved by PIXE analysis or ordinary Nuclepore polycarbonate filter samples. The concentration results were compared with those obtained from routine atomic absorption spectrometry measurements and with the PIXE data from Nuclepore stacked filter unit samples taken in parallel. (orig.)

  9. [Microbial air purity in hospitals. Operating theatres with air conditioning system].

    Science.gov (United States)

    Krogulski, Adam; Szczotko, Maciej

    2010-01-01

    The aim of this study was to show the influence of air conditioning control for microbial contamination of air inside the operating theatres equipped with correctly working air-conditioning system. This work was based on the results of bacteria and fungi concentration in hospital air obtained since 2001. Assays of microbial air purity conducted on atmospheric air in parallel with indoor air demonstrated that air filters applied in air-conditioning systems worked correctly in every case. To show the problem of fluctuation of bacteria concentration more precisely, every sequences of single results from successive measure series were examined independently.

  10. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bergey, Daniel [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  11. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Somerville, MA (United States); Bergey, Daniel [Building Science Corporation, Somerville, MA (United States)

    2014-02-01

    In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  12. Comparison of the Performance of Chilled Beam with Swirl Jet and Diffuse Ceiling Air Supply: Impact of Heat Load Distribution

    DEFF Research Database (Denmark)

    Bertheussen, Bård; Mustakallio, Panu; Kosonen, Risto

    2013-01-01

    The impact of heat load strength and positioning on the indoor environment generated by diffuse ceiling air supply and chilled beam with radial swirl jet was studied and compared. An office room with two persons and a meeting room with six persons were simulated in a test room (4.5 x 3.95 x 3.5 m3......) and Category B thermal environment in the meeting room at high heat load of 94 W∙m−2. The air distribution pattern was influenced by the convective flows from the heat sources. The maximum local velocity in the occupied zone was 0.23–0.26 m∙s−1. The diffuse ceiling supply did not ensure complete mixing...... temperature was controlled at 24 °C. The quality of the generated indoor environment as defined in ISO standard 7730 (2005) was assessed based on comprehensive physical measurements. The systems created Category A thermal environment in cooling situations at heat load of 50 W∙m−2 and 78 W∙m−2 (office room...

  13. EML Surface Air Sampling Program, 1990--1993 data

    International Nuclear Information System (INIS)

    Larsen, R.J.; Sanderson, C.G.; Kada, J.

    1995-11-01

    Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory's Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of 137 Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, 7 Be and 210 Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of 7 Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of 7 Be and 210 Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of 7 Be, 95 Zr, 137 Cs, 144 Ce, and 210 Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of 7 Be, 95 Zr, 137 Cs, 144 Ce, and 210 Pb for samples collected during 1990--1993 are given for 17 sites

  14. A highly linear baseband Gm-C filter for WLAN application

    International Nuclear Information System (INIS)

    Yang Lijun; Chen Zhiming; Gong Zheng; Shi Yin

    2011-01-01

    A low voltage, highly linear transconductan-C (G m -C) low-pass filter for wireless local area network (WLAN) transceiver application is proposed. This transmitter (Tx) filter adopts a 9.8 MHz 3rd-order Chebyshev low pass prototype and achieves 35 dB stop-band attenuation at 30 MHz frequency. By utilizing pseudo-differential linear-region MOS transconductors, the filter IIP 3 is measured to be as high as 9.5 dBm. Fabricated in a 0.35 μm standard CMOS technology, the proposed filter chip occupies a 0.41 x 0.17 mm 2 die area and consumes 3.36 mA from a 3.3-V power supply. (semiconductor integrated circuits)

  15. Modelling of a sand bed filter in the cell exhaust air pathway

    International Nuclear Information System (INIS)

    Schmid, M.

    1983-01-01

    Sandbed filters are appropriate incident filters for zircaloy fires, dissolver fires, and explosions. The alternative treatment of these incidents with and without SBF can thus also quantify the safety gain if an SBF is used. The SBF is considered to be a pure incident filter and according to a planning the SBF is by-passed during normal operation. In case of a temperature rise in the cell the by-pass is blocked by a fire protection valve. (orig./DG) [de

  16. Safety-related control air systems

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This Standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This Standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this Standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  17. Transient Heating and Thermomechanical Stress Modeling of Ceramic HEPA Filters

    Energy Technology Data Exchange (ETDEWEB)

    Bogle, Brandon [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kelly, James [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haslam, Jeffrey [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-29

    The purpose of this report is to showcase an initial finite-element analysis model of a ceramic High-Efficiency Particulate (HEPA) Air filter design. Next generation HEPA filter assemblies are being developed at LLNL to withstand high-temperature fire scenarios by use of ceramics and advanced materials. The filters are meant for use in radiological and nuclear facilities, and are required to survive 500°C fires over an hour duration. During such conditions, however, collecting data under varying parameters can be challenging; therefore, a Finite Element Analysis model of the filter was conducted using COMSOL ® Multiphysics to analyze the effects of fire. Finite Element Analysis (FEA) modelling offers several opportunities: researchers can quickly and easily consider impacts of potential design changes, material selection, and flow characterization on filter performance. Specifically, this model provides stress references for the sealant at high temperatures. Modeling of full filter assemblies was deemed inefficient given the computational requirements, so a section of three tubes from the assembly was modeled. The model looked at the transient heating and thermomechanical stress development during a 500°C air flow at 6 CFM. Significant stresses were found at the ceramic-metal interfaces of the filter, and conservative temperature profiles at locations of interest were plotted. The model can be used for the development of sealants that minimize stresses at the ceramic-metal interface. Further work on the model would include the full filter assembly and consider heat losses to make more accurate predictions.

  18. Nanoparticle filtration performance of NIOSH-certified particulate air-purifying filtering facepiece respirators: evaluation by light scattering photometric and particle number-based test methods.

    Science.gov (United States)

    Rengasamy, Samy; Eimer, Benjamin C

    2012-01-01

    National Institute for Occupational Safety and Health (NIOSH) certification test methods employ charge neutralized NaCl or dioctyl phthalate (DOP) aerosols to measure filter penetration levels of air-purifying particulate respirators photometrically using a TSI 8130 automated filter tester at 85 L/min. A previous study in our laboratory found that widely different filter penetration levels were measured for nanoparticles depending on whether a particle number (count)-based detector or a photometric detector was used. The purpose of this study was to better understand the influence of key test parameters, including filter media type, challenge aerosol size range, and detector system. Initial penetration levels for 17 models of NIOSH-approved N-, R-, and P-series filtering facepiece respirators were measured using the TSI 8130 photometric method and compared with the particle number-based penetration (obtained using two ultrafine condensation particle counters) for the same challenge aerosols generated by the TSI 8130. In general, the penetration obtained by the photometric method was less than the penetration obtained with the number-based method. Filter penetration was also measured for ambient room aerosols. Penetration measured by the TSI 8130 photometric method was lower than the number-based ambient aerosol penetration values. Number-based monodisperse NaCl aerosol penetration measurements showed that the most penetrating particle size was in the 50 nm range for all respirator models tested, with the exception of one model at ~200 nm size. Respirator models containing electrostatic filter media also showed lower penetration values with the TSI 8130 photometric method than the number-based penetration obtained for the most penetrating monodisperse particles. Results suggest that to provide a more challenging respirator filter test method than what is currently used for respirators containing electrostatic media, the test method should utilize a sufficient number

  19. Optimisation of compressed-air supply for control purposes at Valorec Services AG; Optimierung der Steuerluft - Versorgung bei der Valorec Services AG

    Energy Technology Data Exchange (ETDEWEB)

    Dott, R.; Afjei, T.

    2005-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that looked at the possibilities of optimising the supply of compressed air provided around the clock by four compressor systems of varying ages in a facility in Basle, Switzerland. The initial situation is analysed and the potential for making savings is estimated. Various possibilities for improvement are considered including changing the topology of the compressed-air network, the replacement of certain compressors and a new control system. Appropriate measures are proposed and compared with new installations.

  20. Development and modelling of a steel slag filter effluent neutralization process with CO2-enriched air from an upstream bioprocess.

    Science.gov (United States)

    Bove, Patricia; Claveau-Mallet, Dominique; Boutet, Étienne; Lida, Félix; Comeau, Yves

    2018-02-01

    The main objective of this project was to develop a steel slag filter effluent neutralization process by acidification with CO 2 -enriched air coming from a bioprocess. Sub-objectives were to evaluate the neutralization capacity of different configurations of neutralization units in lab-scale conditions and to propose a design model of steel slag effluent neutralization. Two lab-scale column neutralization units fed with two different types of influent were operated at hydraulic retention time of 10 h. Tested variables were mode of flow (saturated or percolating), type of media (none, gravel, Bionest and AnoxKaldnes K3), type of air (ambient or CO 2 -enriched) and airflow rate. One neutralization field test (saturated and no media, 2000-5000 ppm CO 2 , sequential feeding, hydraulic retention time of 7.8 h) was conducted for 7 days. Lab-scale and field-scale tests resulted in effluent pH of 7.5-9.5 when the aeration rate was sufficiently high. A model was implemented in the PHREEQC software and was based on the carbonate system, CO 2 transfer and calcite precipitation; and was calibrated on ambient air lab tests. The model was validated with CO 2 -enriched air lab and field tests, providing satisfactory validation results over a wide range of CO 2 concentrations. The flow mode had a major impact on CO 2 transfer and hydraulic efficiency, while the type of media had little influence. The flow mode also had a major impact on the calcite surface concentration in the reactor: it was constant in saturated mode and was increasing in percolating mode. Predictions could be made for different steel slag effluent pH and different operation conditions (hydraulic retention time, CO 2 concentration, media and mode of flow). The pH of the steel slag filter effluent and the CO 2 concentration of the enriched air were factors that influenced most the effluent pH of the neutralization process. An increased concentration in CO 2 in the enriched air reduced calcite precipitation

  1. Performance analysis of air conditioning system and airflow simulation in an operating theater

    Science.gov (United States)

    Alhamid, Muhammad Idrus; Budihardjo, Rahmat

    2018-02-01

    The importance of maintaining performance of a hospital operating theater is to establish an adequate circulation of clean air within the room. The parameter of air distribution in a space should be based on Air Changes per Hour (ACH) to maintain a positive room pressure. The dispersion of airborne particles in the operating theater was governed by regulating the air distribution so that the operating theater meets clean room standards ie ISO 14664 and ASHRAE 170. Here, we introduced several input parameters in a simulation environment to observe the pressure distribution in the room. Input parameters were air temperature, air velocity and volumetric flow rate entering and leaving room for existing and designed condition. In the existing operating theatre, several observations were found. It was found that the outlet air velocity at the HEPA filter above the operating table was too high thus causing a turbulent airflow pattern. Moreover, the setting temperature at 19°C was found to be too low. The supply of air into the room was observed at lower than 20 ACH which is under the standard requirement. Our simulation using FloVent 8.2™ program showed that not only airflow turbulence could be reduced but also the amount of particle contamination could also be minimized.

  2. Boundary conditions for natural supply ventilation

    NARCIS (Netherlands)

    Jansen, D.W.L.; Loomans, M.G.L.C.; Wit, de M.H.; Zeiler, W.; Seppänen, O.; Säteri, J.

    2007-01-01

    The development of an air jet from a controlled natural ventilation grill for different outdoor conditions is studied. Extensive laboratory measurements are taken in different situations, while the air flow rate through the grill is kept constant. The grill setting and supply temperature are varied.

  3. Method for contamination control and barrier apparatus with filter for containing waste materials that include dangerous particulate matter

    Science.gov (United States)

    Pinson, Paul A.

    1998-01-01

    A container for hazardous waste materials that includes air or other gas carrying dangerous particulate matter has incorporated in barrier material, preferably in the form of a flexible sheet, one or more filters for the dangerous particulate matter sealably attached to such barrier material. The filter is preferably a HEPA type filter and is preferably chemically bonded to the barrier materials. The filter or filters are preferably flexibly bonded to the barrier material marginally and peripherally of the filter or marginally and peripherally of air or other gas outlet openings in the barrier material, which may be a plastic bag. The filter may be provided with a backing panel of barrier material having an opening or openings for the passage of air or other gas into the filter or filters. Such backing panel is bonded marginally and peripherally thereof to the barrier material or to both it and the filter or filters. A coupling or couplings for deflating and inflating the container may be incorporated. Confining a hazardous waste material in such a container, rapidly deflating the container and disposing of the container, constitutes one aspect of the method of the invention. The chemical bonding procedure for producing the container constitutes another aspect of the method of the invention.

  4. Method for contamination control and barrier apparatus with filter for containing waste materials that include dangerous particulate matter

    International Nuclear Information System (INIS)

    Pinson, P.A.

    1998-01-01

    A container for hazardous waste materials that includes air or other gas carrying dangerous particulate matter has incorporated barrier material, preferably in the form of a flexible sheet, and one or more filters for the dangerous particulate matter sealably attached to such barrier material. The filter is preferably a HEPA type filter and is preferably chemically bonded to the barrier materials. The filter or filters are preferably flexibly bonded to the barrier material marginally and peripherally of the filter or marginally and peripherally of air or other gas outlet openings in the barrier material, which may be a plastic bag. The filter may be provided with a backing panel of barrier material having an opening or openings for the passage of air or other gas into the filter or filters. Such backing panel is bonded marginally and peripherally thereof to the barrier material or to both it and the filter or filters. A coupling or couplings for deflating and inflating the container may be incorporated. Confining a hazardous waste material in such a container, rapidly deflating the container and disposing of the container, constitutes one aspect of the method of the invention. The chemical bonding procedure for producing the container constitutes another aspect of the method of the invention. 3 figs

  5. Numerical and experimental study of pulse-jet cleaning in fabric filters

    DEFF Research Database (Denmark)

    O. Andersen, B.; Nielsen, N. F.; Walther, J. H.

    2016-01-01

    Pulse-jet cleaning and understanding of the complex physics are essential when designing fabric filters used for air pollution control. Today, low-pressure cleaning is of particular interest due to demand for reduced compressed air consumption. Pulse-jet cleaned fabric filters have been studied......-pressure fabric filters (2 bar) is studied using a full three-dimensional (3D) CFD model. Experimental results obtained in a pilot-scale test filter with 28 bags, in length of 10 m and in general full-scale dimensions of the cleaning system are used to verify the reliability of the present CFD model....... The validated CFD model reveals the strong compressible effects, a highly transient behaviour, the formation of compressible vortex rings and the shock cell phenomenon within the overexpanded supersonic jet. The cleaning nozzles and venturi design aid or oppose the pulse-pressure within the bags, and this plays...

  6. SEMICONDUCTOR INTEGRATED CIRCUITS: An asymmetric MOSFET-C band-pass filter with on-chip charge pump auto-tuning

    Science.gov (United States)

    Fangxiong, Chen; Min, Lin; Heping, Ma; Hailong, Jia; Yin, Shi; Forster, Dai

    2009-08-01

    An asymmetric MOSFET-C band-pass filter (BPF) with on chip charge pump auto-tuning is presented. It is implemented in UMC (United Manufacturing Corporation) 0.18 μm CMOS process technology. The filter system with auto-tuning uses a master-slave technique for continuous tuning in which the charge pump outputs 2.663 V, much higher than the power supply voltage, to improve the linearity of the filter. The main filter with third order low-pass and second order high-pass properties is an asymmetric band-pass filter with bandwidth of 2.730-5.340 MHz. The in-band third order harmonic input intercept point (IIP3) is 16.621 dBm, with 50 Ω as the source impedance. The input referred noise is about 47.455 μVrms. The main filter dissipates 3.528 mW while the auto-tuning system dissipates 2.412 mW from a 1.8 V power supply. The filter with the auto-tuning system occupies 0.592 mm2 and it can be utilized in GPS (global positioning system) and Bluetooth systems.

  7. Evaluation of sampling methods for Bacillus spore-contaminated HVAC filters

    OpenAIRE

    Calfee, M. Worth; Rose, Laura J.; Tufts, Jenia; Morse, Stephen; Clayton, Matt; Touati, Abderrahmane; Griffin-Gatchalian, Nicole; Slone, Christina; McSweeney, Neal

    2013-01-01

    The objective of this study was to compare an extraction-based sampling method to two vacuum-based sampling methods (vacuum sock and 37 mm cassette filter) with regards to their ability to recover Bacillus atrophaeus spores (surrogate for Bacillus anthracis) from pleated heating, ventilation, and air conditioning (HVAC) filters that are typically found in commercial and residential buildings. Electrostatic and mechanical HVAC filters were tested, both without and after loading with dust to 50...

  8. Nitrification of ammonia polluted air in trickling filters

    NARCIS (Netherlands)

    Smits, M.C.J.; Ottengraf, S.P.P.; Heuvel, van den J.C.

    1994-01-01

    The macro-kinetic behavior of a 12 dm3 nitrifying biotrickling filter and micro-kinetic behavior of 2 mm nitrifying aggregates from a fluidized bed reactor were investigated. Micro-kinetics were studied with micro-electrodes for O, pH, NH4+, and NO3-. The tip diams. of .apprx.2 mm allow a sufficient

  9. DNA accumulation on ventilation system filters in university buildings in Singapore.

    Science.gov (United States)

    Luhung, Irvan; Wu, Yan; Xu, Siyu; Yamamoto, Naomichi; Chang, Victor Wei-Chung; Nazaroff, William W

    2017-01-01

    Biological particles deposit on air handling system filters as they process air. This study reports and interprets abundance and diversity information regarding biomass accumulation on ordinarily used filters acquired from several locations in a university environment. DNA-based analysis was applied both to quantify (via DNA fluorometry and qPCR) and to characterize (via high-throughput sequencing) the microbial material on filters, which mainly processed recirculated indoor air. Results were interpreted in relation to building occupancy and ventilation system operational parameters. Based on accumulated biomass, average DNA concentrations per AHU filter surface area across nine indoor locations after twelve weeks of filter use were in the respective ranges 1.1 to 41 ng per cm2 for total DNA, 0.02 to 3.3 ng per cm2 for bacterial DNA and 0.2 to 2.0 ng DNA per cm2 for fungal DNA. The most abundant genera detected on the AHU filter samples were Clostridium, Streptophyta, Bacillus, Acinetobacter and Ktedonobacter for bacteria and Aspergillus, Cladosporium, Nigrospora, Rigidoporus and Lentinus for fungi. Conditional indoor airborne DNA concentrations (median (range)) were estimated to be 13 (2.6-107) pg/m3 for total DNA, 0.4 (0.05-8.4) pg/m3 for bacterial DNA and 2.3 (1.0-5.1) pg/m3 for fungal DNA. Conditional airborne concentrations and the relative abundances of selected groups of genera correlate well with occupancy level. Bacterial DNA was found to be more responsive than fungal DNA to differences in occupancy level and indoor environmental conditions.

  10. Analysis of an MCU HEPA filter

    Energy Technology Data Exchange (ETDEWEB)

    Peters, T. B. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Fondeur, F. F. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-01-01

    A series of direct analyses on three portions (inlet, center, and outlet) of the High Efficiency Particulate Air (HEPA) filter material from the Modular Caustic-Side Solvent Extraction Unit (MCU) have been performed; this includes x-ray methods such as X-Ray Diffraction (XRD), Contained Scanning Electron Microscopy (CSEM) and X-Ray Fluorescence (XRF), as well as Fourier Transform InfraRed spectroscopy (FTIR). Additionally, two leaching studies (one with water, one with dichloromethane) have been performed on three portions (inlet, center, and outlet) of the HEPA filter material, with the leachates being analyzed by Inductively-coupled plasma emission spectroscopy (ICPES), Semi-Volatile Organic Analysis (SVOA) and gammascan. From the results of the analyses, SRNL feels that cesium-depleted solvent is being introduced into the HEPA filter. The most likely avenue for this is mechanical aerosolization of solvent, where the aerosol is then carried along an airstream into the HEPA filter. Once introduced into the HEPA filter media, the solvent wicks throughout the material, and migrates towards the outlet end. Once on the outlet end, continual drying could cause particulate flakes to exit the filter and travel farther down the airstream path.

  11. In-place HEPA filter penetration test

    Energy Technology Data Exchange (ETDEWEB)

    Bergman, W.; Wilson, K.; Elliott, J. [Lawrence Livermore National Lab., CA (United States)] [and others

    1997-08-01

    We have demonstrated the feasibility of conducting penetration tests on high efficiency particulate air (HEPA) filters as installed in nuclear ventilation systems. The in-place penetration test, which is designed to yield equivalent penetration measurements as the standard DOP efficiency test, is based on measuring the aerosol penetration of the filter installation as a function of particle size using a portable laser particle counter. This in-place penetration test is compared to the current in-place leak test using light scattering photometers for single HEPA filter installations and for HEPA filter plenums using the shroud method. Test results show the in-place penetration test is more sensitive than the in-place leak test, has a similar operating procedure, but takes longer to conduct. Additional tests are required to confirm that the in-place penetration test yields identical results as the standard dioctyl phthalate (DOP) penetration test for HEPA filters with controlled leaks in the filter and gasket and duct by-pass leaks. Further development of the procedure is also required to reduce the test time before the in-place penetration test is practical. 14 refs., 14 figs., 3 tabs.

  12. Results from Evaluation of Proposed ASME AG-1 Section FI Metal Media Filters - 13063

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, John A.; Giffin, Paxton K.; Parsons, Michael S.; Waggoner, Charles A. [Institute for Clean Energy Technology, Mississippi State University, 205 Research Blvd Starkville, MS 39759 (United States)

    2013-07-01

    High efficiency particulate air (HEPA) filtration technology is commonly used in Department of Energy (DOE) facilities that require control of radioactive particulate matter (PM) emissions due to treatment or management of radioactive materials. Although HEPA technology typically makes use of glass fiber media, metal and ceramic media filters are also capable of filtering efficiencies beyond the required 99.97%. Sintered metal fiber filters are good candidates for use in DOE facilities due to their resistance to corrosive environments and resilience at high temperature and elevated levels of relative humidity. Their strength can protect them from high differential pressure or pressure spikes and allow for back pulse cleaning, extending filter lifetime. Use of these filters has the potential to reduce the cost of filtration in DOE facilities due to life cycle cost savings. ASME AG-1 section FI has not been approved due to a lack of protocols and performance criteria for qualifying section FI filters. The Institute for Clean Energy Technology (ICET) with the aid of the FI project team has developed a Section FI test stand and test plan capable of assisting in the qualification ASME AG-1 section FI filters. Testing done at ICET using the FI test stand evaluates resistance to rated air flow, test aerosol penetration and resistance to heated air of the section FI filters. Data collected during this testing consists of temperature, relative humidity, differential pressure, flow rate, upstream particle concentration, and downstream particle concentration. (authors)

  13. Strategy Guideline: Compact Air Distribution Systems

    Energy Technology Data Exchange (ETDEWEB)

    Burdick, A.

    2013-06-01

    This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  14. Operation technology of air treatment system in nuclear facilities

    CERN Document Server

    Chun, Y B; Hwong, Y H; Lee, H K; Min, D K; Park, K J; Uom, S H; Yang, S Y

    2001-01-01

    Effective operation techniques were reviewed on the air treatment system to protect the personnel in nuclear facilities from the contamination of radio-active particles and to keep the environment clear. Nuclear air treatment system consisted of the ventilation and filtering system was characterized by some test. Measurement of air velocity of blowing/exhaust fan in the ventilation system, leak tests of HEPA filters in the filtering, and measurement of pressure difference between the areas defined by radiation level were conducted. The results acquired form the measurements were reflected directly for the operation of air treatment. In the abnormal state of virus parts of devices composted of the system, the repairing method, maintenance and performance test were also employed in operating effectively the air treatment system. These measuring results and techniques can be available to the operation of air treatment system of PIEF as well as the other nuclear facilities in KAERI.

  15. Printed Self-Powered Miniature Air Sampling Sensors

    Directory of Open Access Journals (Sweden)

    Joseph Birmingham

    2017-07-01

    Full Text Available The recent geo-political climate has increased the necessity for autonomous, chip-sized, lightweight, air sampling systems which can quickly detect and characterize chemical, biological, radiological, nuclear, and high explosive (CBRNE hazardous materials and relay the results. To address these issues, we have developed a self-powered 3-D chip architecture that processes air to produce concentrated size- sorted particle (and vapor samples that could be integrated with on-chip nanoelectronic detectors for the discovery of weapons of mass destruction (WMD. The unique air movement approach is composed of a nanoscale energy harvester that provides electricity to a printed ion-drag pump to push air through coated-microstructured arrays. The self-powered microstructured array air sampler was designed using computational fluid dynamics (CFD modeling to collect particles from 1-10 microns at greater than 99.9999 % efficiency with less than 100 Pascal [Pa] pressure drop at a specified air flow rate. Surprisingly, even at minimum air flow rates below specifications, these CFD predictions were matched by experimental results gathered in a Government aerosol chamber. The microstructured array engineered filter equaled the collection capability of a membrane or a high efficiency particle air (HEPA filter at a fraction of the filter pressure drop.

  16. Detection of Harmonic Occurring using Kalman Filtering

    DEFF Research Database (Denmark)

    Hussain, Dil Muhammad Akbar; Shoro, Ghulam Mustafa; Imran, Raja Muhammed

    2014-01-01

    /current characteristic. These harmonics are not to be allowed to grow beyond a certain limit to avoid any grave consequence to the customer’s main supply. Filters can be implemented at the power source or utility location to eliminate these harmonics. In this paper we detect the instance at which these harmonics occur...

  17. EML Surface Air Sampling Program, 1990--1993 data

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, R.J.; Sanderson, C.G.; Kada, J.

    1995-11-01

    Measurements of the concentrations of specific atmospheric radionuclides in air filter samples collected for the Environmental Measurements Laboratory`s Surface Air Sampling Program (SASP) during 1990--1993, with the exception of April 1993, indicate that anthropogenic radionuclides, in both hemispheres, were at or below the lower limits of detection for the sampling and analytical techniques that were used to collect and measure them. The occasional detection of {sup 137}Cs in some air filter samples may have resulted from resuspension of previously deposited debris. Following the April 6, 1993 accident and release of radionuclides into the atmosphere at a reprocessing plant in the Tomsk-7 military nuclear complex located 16 km north of the Siberian city of Tomsk, Russia, weekly air filter samples from Barrow, Alaska; Thule, Greenland and Moosonee, Canada were selected for special analyses. The naturally occurring radioisotopes that the authors measure, {sup 7}Be and {sup 210}Pb, continue to be detected in most air filter samples. Variations in the annual mean concentrations of {sup 7}Be at many of the sites appear to result primarily from changes in the atmospheric production rate of this cosmogenic radionuclide. Short-term variations in the concentrations of {sup 7}Be and {sup 210}Pb continued to be observed at many sites at which weekly air filter samples were analyzed. The monthly gross gamma-ray activity and the monthly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb measured at sampling sites in SASP during 1990--1993 are presented. The weekly mean surface air concentrations of {sup 7}Be, {sup 95}Zr, {sup 137}Cs, {sup 144}Ce, and {sup 210}Pb for samples collected during 1990--1993 are given for 17 sites.

  18. Stabilization void-fill encapsulation high-efficiency particulate filters

    International Nuclear Information System (INIS)

    Alexander, R.G.; Stewart, W.E.; Phillips, S.J.; Serkowski, M.M.; England, J.L.; Boynton, H.C.

    1994-05-01

    This report discusses high-efficiency particulate air (HEPA) filter systems that which are contaminated with radionuclides are part of the nuclear fuel processing systems conducted by the US Department of Energy (DOE) and require replacement and safe and efficient disposal for plant safety. Two K-3 HEPA filters were removed from service, placed burial boxes, buried, and safely and efficiently stabilized remotely which reduced radiation exposure to personnel and the environment

  19. Manufacturing a low-cost ceramic water filter and filter system for the elimination of common pathogenic bacteria

    Science.gov (United States)

    Simonis, J. J.; Basson, A. K.

    Africa is one of the most water-scarce continents in the world but it is the lack of potable water which results in diarrhoea being the leading cause of death amongst children under the age of five in Africa (696 million children under 5 years old in Africa contract diarrhoea resulting in 2000 deaths per day: WHO and UNICEF, 2009). Most potable water treatment methods use bulk water treatment not suitable or available to the majority of rural poor in Sub-Saharan Africa. One simple but effective way of making sure that water is of good quality is by purifying it by means of a household ceramic water filter. The making and supply of water filters suitable for the removal of suspended solids, pathogenic bacteria and other toxins from drinking water is therefore critical. A micro-porous ceramic water filter with micron-sized pores was developed using the traditional slip casting process. This locally produced filter has the advantage of making use of less raw materials, cost, labour, energy and expertise and being more effective and efficient than other low cost produced filters. The filter is fitted with a silicone tube inserted into a collapsible bag that acts as container and protection for the filter. Enhanced flow is obtained through this filter system. The product was tested using water inoculated with high concentrations of different bacterial cultures as well as with locally polluted stream water. The filter is highly effective (log10 > 4 with 99.99% reduction efficiency) in providing protection from bacteria and suspended solids found in natural water. With correct cleaning and basic maintenance this filter technology can effectively provide drinking water to rural families affected by polluted surface water sources. This is an African solution for the more than 340 million people in Africa without access to clean drinking water (WHO and UNICEF, 2008).

  20. Cleanable sintered metal filters in hot off-gas systems

    International Nuclear Information System (INIS)

    Schurr, G.A.

    1981-01-01

    Filters with sintered metal elements, arranged as tube bundles with backflush air cleaning, are the equivalent of bag filters for high-temperature, harsh environments. They are virtually the only alternative for high-temperature off-gas systems where a renewable, highly efficient particle trap is required. Tests were conducted which show that the sintered metal elements installed in a filter system provide effective powder collection in high-temperature atmospheres over thousands of cleaning cycles. Such a sintered metal filter system is now installed on the experimental defense waste calciner at the Savannah River Laboratory. The experimental results included in this paper were used as the basis for its design

  1. Determination of the radioiodine species in the exhaust air of nuclear facilities

    International Nuclear Information System (INIS)

    Deuber, H.

    1977-01-01

    Using the selective I 2 sorption materials DSM 10 and DSM 11 measurements were performed with radioiodine species samplers in the exhaust air of a research reactor and of several nuclear power stations (BWR, PWR). The radioiodine species samplers were used upstream and downstream of iodine filters (containment exhaust air stand-by filter, shutoff room exhaust air filter) as well as in the exhaust air of the stack. The results obtained by use of DSM 10 and DSM 11 generally agreed. The percentage of aerosol iodine was low in all cases ( [de

  2. Filter-adsorber aging assessment

    Energy Technology Data Exchange (ETDEWEB)

    Winegardner, W.K. [Pacific Northwest Laboratory, Richland, WA (United States)

    1995-02-01

    An aging assessment of high-efficiency particulate (HEPA) air filters and activated carbon gas adsorption units was performed by the Pacific Northwest Laboratory as part of the U.S. Nuclear Regulatory Commission`s (USNRC) Nuclear Plant Aging Research (NPAR) Program. This evaluation of the general process in which characteristics of these two components gradually change with time or use included the compilation of information concerning failure experience, stressors, aging mechanisms and effects, and inspection, surveillance, and monitoring methods (ISMM). Stressors, the agents or stimuli that can produce aging degradation, include heat, radiation, volatile contaminants, and even normal concentrations of aerosol particles and gasses. In an experimental evaluation of degradation in terms of the tensile breaking strength of aged filter media specimens, over forty percent of the samples did not meet specifications for new material. Chemical and physical reactions can gradually embrittle sealants and gaskets as well as filter media. Mechanisms that can lead to impaired adsorber performance are associated with the loss of potentially available active sites as a result of the exposure of the carbon to airborne moisture or volatile organic compounds. Inspection, surveillance, and monitoring methods have been established to observe filter pressure drop buildup, check HEPA filters and adsorbers for bypass, and determine the retention effectiveness of aged carbon. These evaluations of installed filters do not reveal degradation in terms of reduced media strength but that under normal conditions aged media can continue to effectively retain particles. However, this degradation may be important when considering the likelihood of moisture, steam, and higher particle loadings during severe accidents and the fact it is probable that the filters have been in use for an extended period.

  3. Measurement of radon daughters in air samples by alpha spectroscopy

    International Nuclear Information System (INIS)

    Acena, M.L.; Crespo, M.T.

    1989-01-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of polonium 214 and polonium 218. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter (Author)

  4. 40 CFR 89.326 - Engine intake air humidity measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air humidity measurement... Test Equipment Provisions § 89.326 Engine intake air humidity measurement. (a) Humidity conditioned air... type of intake air supply, the humidity measurements must be made within the intake air supply system...

  5. 40 CFR 91.310 - Engine intake air humidity measurement.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Engine intake air humidity measurement... Provisions § 91.310 Engine intake air humidity measurement. This section refers to engines which are supplied... air, the ambient testcell humidity measurement may be used. (a) Humidity conditioned air supply. Air...

  6. Penetration of Combustion Aerosol Particles Through Filters of NIOSH-Certified Filtering Facepiece Respirators (FFRs).

    Science.gov (United States)

    Gao, Shuang; Kim, Jinyong; Yermakov, Michael; Elmashae, Yousef; He, Xinjian; Reponen, Tiina; Grinshpun, Sergey A

    2015-01-01

    Filtering facepiece respirators (FFRs) are commonly worn by first responders, first receivers, and other exposed groups to protect against exposure to airborne particles, including those originated by combustion. Most of these FFRs are NIOSH-certified (e.g., N95-type) based on the performance testing of their filters against charge-equilibrated aerosol challenges, e.g., NaCl. However, it has not been examined if the filtration data obtained with the NaCl-challenged FFR filters adequately represent the protection against real aerosol hazards such as combustion particles. A filter sample of N95 FFR mounted on a specially designed holder was challenged with NaCl particles and three combustion aerosols generated in a test chamber by burning wood, paper, and plastic. The concentrations upstream (Cup) and downstream (Cdown) of the filter were measured with a TSI P-Trak condensation particle counter and a Grimm Nanocheck particle spectrometer. Penetration was determined as (Cdown/Cup) ×100%. Four test conditions were chosen to represent inhalation flows of 15, 30, 55, and 85 L/min. Results showed that the penetration values of combustion particles were significantly higher than those of the "model" NaCl particles (p combustion particles. Aerosol type, inhalation flow rate and particle size were significant (p combustion particles through R95 and P95 FFR filters (were tested in addition to N95) were not significantly higher than that obtained with NaCl particles. The findings were attributed to several effects, including the degradation of an N95 filter due to hydrophobic organic components generated into the air by combustion. Their interaction with fibers is anticipated to be similar to those involving "oily" particles. The findings of this study suggest that the efficiency of N95 respirator filters obtained with the NaCl aerosol challenge may not accurately predict (and rather overestimate) the filter efficiency against combustion particles.

  7. Air ventilation/controlling facility

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kazuhiro; Kinoshita, Shoichiro

    1997-12-12

    When all electricity supply from the outside of a power plant are lost, a power generator directly connected to an emergency steam turbine which is driven by steams introduced from a nuclear reactor is driven to supply electricity required in the power plant. Cool water prepared by a refrigerator is used as cooling water in an air ventilation/controlling facility of a room equipped with the power generating facility. As the refrigerator, a refrigerator of an existent emergency air cooling water system for an auxiliary air ventilation/controlling equipment is used. This can extend the period of time till the temperature of the room where the power generator is disposed exceeds the temperature range capable of keeping the integrity of the power generator even when all the AC power supply are lost to inactivate the function of the air ventilation/controlling system. (I.S.)

  8. Respirator studies for the Nuclear Regulatory Commission. Protection factors for supplied-air respirators. Progress report, October 1, 1976--September 30, 1977

    International Nuclear Information System (INIS)

    Hack, A.; Bradley, O.D.; Trujillo, A.

    1977-12-01

    This report describes the work performed during FY 1977 for the Nuclear Regulatory Commission. The Protection Factors (efficiency) provided by 25 NIOSH approved supplied-air respirators were determined while the devices were worn by a panel of anthropometrically selected test subjects. The major recommendation was that demand-type respirators should neither be used nor approved

  9. The triple-A supply chain.

    Science.gov (United States)

    Lee, Hau L

    2004-10-01

    Building a strong supply chain is essential for business success. But when it comes to improving their supply chains, few companies take the right approach. Many businesses work to make their chains faster or more cost-effective, assuming that those steps are the keys to competitive advantage. To the contrary: Supply chains that focus on speed and costs tend to deteriorate over time. The author has spent 15 years studying more than 60 companies to gain insight into this and other supply chain dilemmas. His conclusion: Only companies that build supply chains that are agile, adaptable, and aligned get ahead of their rivals. All three components are essential; without any one of them, supply chains break down. Great companies create supply chains that respond to abrupt changes in markets. Agility is critical because in most industries, both demand and supply fluctuate rapidly and widely. Supply chains typically cope by playing speed against costs, but agile ones respond both quickly and cost-efficiently. Great companies also adapt their supply networks when markets or strategies change. The best supply chains allow managers to identify structural shifts early by recording the latest data, filtering out noise, and tracking key patterns. Finally, great companies align the interests of the partners in their supply chains with their own. That's important because every firm is concerned solely with its own interests. If its goals are out of alignment with those of other partners in the supply chain, performance will suffer. When companies hear about the triple-A supply chain, they assume that building one will require increased technology and investment. But most firms already have the infrastructure in place to create one. A fresh attitude alone can go a long way toward making it happen.

  10. The use of nylon and glass fiber filter separators with different pore sizes in air-cathode single-chamber microbial fuel cells

    KAUST Repository

    Zhang, Xiaoyuan

    2010-01-01

    Separators are needed in microbial fuel cells (MFCs) to reduce electrode spacing and preventing electrode short circuiting. The use of nylon and glass fiber filter separators in single-chamber, air-cathode MFCs was examined for their effect on performance. Larger pore nylon mesh were used that had regular mesh weaves with pores ranging from 10 to 160 μm, while smaller pore-size nylon filters (0.2-0.45 μm) and glass fiber filters (0.7-2.0 μm) had a more random structure. The pore size of both types of nylon filters had a direct and predictable effect on power production, with power increasing from 443 ± 27 to 650 ± 7 mW m-2 for pore sizes of 0.2 and 0.45 μm, and from 769 ± 65 to 941 ± 47 mW m-2 for 10 to 160 μm. In contrast, changes in pore sizes of the glass fiber filters resulted in a relatively narrow change in power (732 ± 48 to 779 ± 43 mW m-2) for pore sizes of 0.7 to 2 μm. An ideal separator should increase both power density and Coulombic efficiency (CE). However, CEs measured for the different separators were inversely correlated with power production, demonstrating that materials which reduced the oxygen diffusion into the reactor also hindered proton transport to the cathode, reducing power production through increased internal resistance. Our results highlight the need to develop separators that control oxygen transfer and facilitate proton transfer to the cathode. © 2010 The Royal Society of Chemistry.

  11. Final Report: Part 1. In-Place Filter Testing Instrument for Nuclear Material Containers. Part 2. Canister Filter Test Standards for Aerosol Capture Rates.

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Austin Douglas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Runnels, Joel T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Moore, Murray E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reeves, Kirk Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-11-02

    A portable instrument has been developed to assess the functionality of filter sand o-rings on nuclear material storage canisters, without requiring removal of the canister lid. Additionally, a set of fifteen filter standards were procured for verifying aerosol leakage and pressure drop measurements in the Los Alamos Filter Test System. The US Department of Energy uses several thousand canisters for storing nuclear material in different chemical and physical forms. Specialized filters are installed into canister lids to allow gases to escape, and to maintain an internal ambient pressure while containing radioactive contaminants. Diagnosing the condition of container filters and canister integrity is important to ensure worker and public safety and for determining the handling requirements of legacy apparatus. This report describes the In-Place-Filter-Tester, the Instrument Development Plan and the Instrument Operating Method that were developed at the Los Alamos National Laboratory to determine the “as found” condition of unopened storage canisters. The Instrument Operating Method provides instructions for future evaluations of as-found canisters packaged with nuclear material. Customized stainless steel canister interfaces were developed for pressure-port access and to apply a suction clamping force for the interface. These are compatible with selected Hagan-style and SAVY-4000 storage canisters that were purchased from NFT (Nuclear Filter Technology, Golden, CO). Two instruments were developed for this effort: an initial Los Alamos POC (Proof-of-Concept) unit and the final Los Alamos IPFT system. The Los Alamos POC was used to create the Instrument Development Plan: (1) to determine the air flow and pressure characteristics associated with canister filter clogging, and (2) to test simulated configurations that mimicked canister leakage paths. The canister leakage scenarios included quantifying: (A) air leakage due to foreign material (i.e. dust and hair

  12. Cost-benefit comparisons of investments in improved water supply and cholera vaccination programs.

    Science.gov (United States)

    Jeuland, Marc; Whittington, Dale

    2009-05-18

    This paper presents the first cost-benefit comparison of improved water supply investments and cholera vaccination programs. Specifically, we compare two water supply interventions -- deep wells with public hand pumps and biosand filters (an in-house, point-of-use water treatment technology) -- with two types of cholera immunization programs with new-generation vaccines -- general community-based and targeted and school-based programs. In addition to these four stand-alone investments, we also analyze five combinations of water and vaccine interventions: (1) borehole+hand pump and community-based cholera vaccination, (2) borehole+hand pump and school-based cholera vaccination, (3) biosand filter and community-based cholera vaccination, (4) biosand filter and school-based cholera vaccination, and (5) biosand filter and borehole+hand pump. Using recent data applicable to developing country locations for parameters such as disease incidence, the effectiveness of vaccine and water supply interventions against diarrheal diseases, and the value of a statistical life, we construct cost-benefit models for evaluating these interventions. We then employ probabilistic sensitivity analysis to estimate a frequency distribution of benefit-cost ratios for all four interventions, given a wide variety of possible parameter combinations. Our results demonstrate that there are many plausible conditions in developing countries under which these interventions will be attractive, but that the two improved water supply interventions and the targeted cholera vaccination program are much more likely to yield attractive cost-benefit outcomes than a community-based vaccination program. We show that implementing community-based cholera vaccination programs after borehole+hand pump or biosand filters have already been installed will rarely be justified. This is especially true when the biosand filters are already in place, because these achieve substantial cholera risk reductions on their own

  13. Concentration of Radon Progeny in Air by Alpha Spectrometry Measurement

    International Nuclear Information System (INIS)

    Acena, M. L.; Crespo, M. T.

    1989-01-01

    The concentration of radon progeny in air has been determined by alpha spectrometry measurement of 214 Po and 318 Po. A known volume of air was passed through a filter, then the alpha activity was directly measured on this filter. (Author) 15 refs

  14. Performance of multiple HEPA filters against plutonium aerosols

    International Nuclear Information System (INIS)

    Gonzales, M.; Elder, J.; Ettinger, H.

    1975-01-01

    Performance of multiple stages of High Efficiency Particulate Air (HEPA) filters against aerosols similar to those produced by plutonium processing facilities has been verified as part of an experimental program. A system of three HEPA filters in series was tested against 238 PuO 2 aerosol concentrations as high as 3.3 x 10 10 d/s-m 3 . An air nebulization aerosol generation system, using ball milled plutonium oxide suspended in water, provided test aerosols with size characteristics similar to those defined by a field sampling program at several different AEC plutonium processing facilities. Aerosols have been produced ranging from 0.22 μm activity median aerodynamic diameter (amad) to 1.6 μm amad. The smaller size distributions yield 10 to 30 percent of the total activity in the less than 0.22 μm size range allowing efficiency measurement as a function of size for the first two HEPA filters in series. The low level of activity on the sampler downstream of the third HEPA filter (approximately 0.01 c/s) precludes aerosol size characterization downstream of this filter. For the first two HEPA filters, overall efficiency, and efficiency as a function of size, exceeds 99.98 percent including the <0.12 μm and the 0.12 to 0.22 μm size intervals. Efficiency of the third HEPA filter is somewhat lower with an overall average efficiency of 99.8 percent and an apparent minimum efficiency of 99.5 percent. This apparently lower efficiency is an artifact due to the low level of activity on the sampler downstream of HEPA No. 3 and the variations due to counting statistics. Recent runs with higher concentrations, thereby improving statistical variations, show efficiencies well within minimum requirements. (U.S.)

  15. Study on the Development of an Optimal Heat Supply Control Algorithm for Group Energy Apartment Buildings According to the Variation of Outdoor Air Temperature

    Directory of Open Access Journals (Sweden)

    Dong-Kurl Kwak

    2012-05-01

    Full Text Available In the present study, we have developed an optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in a group energy apartment. Heating load variation of a group energy apartment building according to the outdoor air temperature was predicted by a correlation obtained from calorimetry measurements of all households in the apartment building. Supply water temperature and mass flow rate were simultaneously controlled to minimize the heat loss rate through the distribution pipe line. A group heating apartment building located in Hwaseong city, Korea, which has 1473 households, was selected as the object building to test the present heat supply algorithm. Compared to the original heat supply system, the present system adopting the proposed control algorithm reduced the heat loss rate by 10.4%.

  16. Filtering the internet for copyrighted content in Europe

    NARCIS (Netherlands)

    Angelopoulos, C.

    2009-01-01

    One issue that has been frequently discussed in the IRIS plus series is the unauthorised supply of copyright protected works via the Internet. The resulting threat of copyright infringements could, at least partly, be prevented through the use of Internet filters, an option that forms the subject of

  17. Comparing charcoal and zeolite reflection filters for volatile anaesthetics: A laboratory evaluation.

    Science.gov (United States)

    Sturesson, Louise W; Frennström, Jan O; Ilardi, Marcella; Reinstrup, Peter

    2015-08-01

    A modified heat-moisture exchanger that incorporates a reflecting filter for use with partial rebreathing of exhaled volatile anaesthetics has been commercially available since the 1990 s. The main advantages of the device are efficient delivery of inhaled sedation to intensive care patients and reduced anaesthetic consumption during anaesthesia. However, elevated arterial CO2 values have been observed with an anaesthetic conserving device compared with a conventional heat and moisture exchanger, despite compensation for larger apparatus dead space. The objective of this study is to thoroughly explore the properties of two reflecting materials (charcoal and zeolites). A controlled, prospective, observational laboratory study. Lund University Hospital, Sweden, from December 2011 to December 2012. None. Three filters, with identical volumes, were compared using different volatile anaesthetics at different conditions of temperature and moisture. The filtering materials were charcoal or zeolite. Glass spheres were used as an inert control. Consumption of volatile anaesthetics using different reflecting materials in filters at different conditions regarding temperature and moisture. CO2 reflection by the filtering materials: glass spheres, charcoal or zeolite. Isoflurane consumption in an open system was 60.8 g h(-1). The isoflurane consumption in dry, warm air was 39.8 g h(-1) with glass spheres. Changing to charcoal and zeolite had a profound effect on isoflurane consumption, 11.8 and 10.7 g h(-1), respectively. Heating and humidifying the air as well as the addition of N2O created only minor changes in consumption. The percentage of isoflurane conserved by the charcoal filter was independent of the isoflurane concentration (0.5 to 4.5%). Reflection of sevoflurane, desflurane and halothane by the charcoal filter was similar to reflection of isoflurane. Both charcoal and zeolite filters had CO2 reflecting properties and end-tidal CO2 increased by 3 to 3.7% compared

  18. The arc power supply for the TEXTOR neutral injectors

    International Nuclear Information System (INIS)

    Schwarz, U.; Pfister, U.; Goll, O.; Wurslin, R.; Scherer, J.; Haubmann, S.

    1986-01-01

    The 24 single arcs in the plasma source of the TEXTOR neutral injector are supplied with an overall current of 1800 A at an arc voltage of 150 V DC. The current is switched on and off in less than 1 msec. The paper presents a new modular solution for such a power supply. Each arc is powered by a separately switched mode supply module. One single module consists of a diode rectifier bridge with a filter, a fast semiconductor switch, an inductance in series for stabilizing the current and a free-wheeling path. The layout of this power supply system is described in detail based on test results. Design features and technical data are given

  19. Study on a Highly Stabilized Power Supply for Hybrid-Magnet Superconducting Outsert

    International Nuclear Information System (INIS)

    Wu Jinglin; Long Jiaojiao; Liu Xiaoning

    2014-01-01

    The superconducting outsert of the 40 T hybrid-magnet in High Magnetic Field Laboratory (HMFL) of Chinese Academy of Sciences (CAS) requires a highly stabilized power supply. In this paper, two kinds of power supply design are briefly presented and both advantages and disadvantages are analyzed. In order to overcome the drawbacks of switching power supply, a series regulated active filter is adopted and a new design is proposed which ensures cooperative relationship between the feedback control loops of the switching converter and the series regulated active filter. Besides, unlike the traditional switching power supply, which can generate positive voltage only, this new design can also generate negative voltage which is needed in the quench protection for the superconducting magnet. In order to demonstrate the effectiveness of the methodology, a low-power prototype has been accomplished. The simulation and experiment results show that the power supply achieves high precision under the combined action of two feedback control loops. The peak-to-peak amplitude of the output ripple voltage of the prototype is 0.063%, while the peak-to-peak amplitude of the output ripple current is 120 ppm. (fusion engineering)

  20. Improved airline-type supplied-air plastic suit. [For personnel protection against inhalation of airborne plutonium and tritium

    Energy Technology Data Exchange (ETDEWEB)

    Jolley, L. Jr.; Zippler, D.B.; Cofer, C.H.; Harper, J.A.

    1978-06-01

    Two piece supplied-air plastic suits are used extensively at the Savannah River Plant for personnel protection against inhalation of airborne plutonium and tritium. Worker comfort and noise level problems gave impetus to development of an improved suit and aid distribution system. The resulting plastic suit and development work are discussed. The plastic suit unit cost is less than $20, the hearing zone noise level is less than 75 dBA, protection factors exceed 10,000, and user comfort is approved. This suit is expected to meet performance requirements for unrestricted use.

  1. 42 CFR 84.162 - Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air...

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements. 84.162 Section 84.162 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL...

  2. AIRFIL: a FORTRAN program for reduction of data obtained from alpha spectrometry of perimeter air filters

    International Nuclear Information System (INIS)

    Hinton, E.R. Jr.; Howell, R.L.

    1984-03-01

    Isotopic alpha spectrometry of 238 U, 235 U, and 234 U, along with gross alpha/beta counting of perimeter air filters, is performed by the Oak Ridge Y-12 Plant Laboratory in support of the Envrirnomental Monitoring Section of the Radiation Safety Department. Weekly samples are gross alpha/beta counted and the isotopic analysis performed on quarterly composites. Calculations and data management represents a major portion of the anlaysis time when performed manually, even with a desktop calculator. In order to reduce calculation time, perform orderly data manipulation and management, reduce errors due to redundant calculations, and eliminate report typing turnaround time, a computer program (AIRFIL) has been developed that performs these functions. The program accepts data through user prompts, then calculates and prints intermediate and final data, including detection limits

  3. Possible negative consequences of the secondary air contamination on the quality of accumulated drinking water

    International Nuclear Information System (INIS)

    Rihova Ambrozova, J.; Hubackova, J.; Cihakova, I.

    2008-01-01

    At the present time when requirements on quality of drinking water are increased, it is necessary not only to put stress on technological processes used in its preparation, but also there is a need to secure that water is distributed even to the consumer in that quality as it leaves a water station. Through a systematic surveillance of water-supply companies within the framework of biological audits it has been found out that the important points in a distribution network where the quality of water is deteriorated are the water reservoirs. Deterioration in quality of accumulated water is jointly caused by elements of technological, constructional and biological nature. The secondary air contamination has a substantial influence on the creation of bio-films on walls and the presence of microorganisms in accumulated drinking water. To this end, a water twin-compartment reservoir has been systematically evaluated during operation, cleaning meantime and before cleaning. The results of hydro-biological and microbiological analysis have confirmed the input of particles and microorganisms through air, their presence in surface level of accumulated water as well as scrapings from accumulation walls. The surveillance considered also the situation without a fixed filter unit, without door lining etc. On fixing a tested filter system into ventilation duct the risk of air contamination was lowered to minimum. (authors)

  4. Investigation of HEPA filters subjected to tornado pressure pulses

    International Nuclear Information System (INIS)

    Gregory, W.S.; Horak, H.L.; Smith, P.R.; Ricketts, C.

    1977-03-01

    An experimental program is described that will determine the response of 0.6-x 0.6-m (24-x 24-in.) high-efficiency particulate air (HEPA) filters to tornado-induced pressure transients. A blow-down system will be used to impose pressure differentials across the filters. Progress in construction of this system is reported with a description of the component parts and their functions. The test facility is essentially complete with the exception of an air dryer system that has not yet been delivered. Initial structural testing will begin in March 1977. A description is given of the instrumentation needed to measure air pressure, velocity, turbulence, humidity and particulate concentration. This instrumentation includes pressure transducers, humidity equipment, laser Doppler velocimeters (LDV), signal processors and a data acquisition system. Operational theory of the LDV and its proposed use as a particle counting device are described

  5. Second Order Washout filter based Power Sharing Strategy for Uninterruptible Power Supply

    DEFF Research Database (Denmark)

    Lu, Jinghang; Savaghebi, Mehdi; Guerrero, Josep M.

    2017-01-01

    In this paper, first, the existing frequency and voltage amplitude restoration control strategies are reviewed. Moreover, the proposed second order washout filter control strategy is proposed to enhance the dynamic response under load disturbance. The physical parameter of the proposed method is ...

  6. Less-Conventional Low-Consumption Galvanic Separated MOSFET-IGBT Gate Drive Supply

    Directory of Open Access Journals (Sweden)

    Jean Marie Vianney Bikorimana

    2017-01-01

    Full Text Available A simple half-bridge, galvanic separated power supply which can be short circuit proof is proposed for gate driver local supplies. The supply is made while hacking a common mode type filter as a transformer, as the transformer shows a good insulation, it has a very low parasitic capacitance between primary and secondary coils, and it is cost-effective. Very low standby losses were observed during lab experiments. This makes it compatible with energy efficient drives and solar inverters.

  7. Problems and remedy programme of an ion-exchange filter

    International Nuclear Information System (INIS)

    Khattab, M.; Mekhemar, S.

    1994-01-01

    Practical problems of the ion exchange filter of ET-R R-1 reactor are discussed. Remedy program is described. The program includes:- Evaluating the efficiency of the resins. -Discharging of the radio-active resins from the filter - Identification of corrosion and repairing process of the filter vessel - Charging process of the fresh resins. -Evaluating the efficiency of the new resins. Waste radio-active resins were discharged by siphon effect. The chloride content in reactor cooling water decreased from 5.8 ppm to 1.1 ppm after changing the resins. Nevertheless, the chloride content is still much higher than the standard value 0.05 ppm. This is due to the high level of the chloride in the demineralized water produced by the demineralizer, 0.8 ppm. Therefore, it is recommended that the resins of the mixed bed demineralizer be tailored to produce the standard water quality. The filter vessel cannot be quarantined to be in good service condition for a long period. The vessel should be replaced by a new design which would facilitate the process of discharging the radioactive resins and charging the fresh resins. The inner surface of the vessel should be coated or cladded to withstand the aggressive environment of the water. Periodical water chemical analysis is necessary to investigate reactor coolant and filter conditions. The aging effect of the stored water supply to the reactor should be taken into consideration. New demineralized should be installed near the feed water supply tanks so that the stored water could be refreshed. The device save the costs of production of fresh demineralized water. Development of radioactive waste transportation mechanisms and storing are necessary. 12 figs., 4 tabs

  8. THE PHASE REACTOR INDUCTANCE SELECTION TECHNIQUE FOR POWER ACTIVE FILTER

    Directory of Open Access Journals (Sweden)

    D. V. Tugay

    2016-12-01

    Full Text Available Purpose. The goal is to develop technique of the phase inductance power reactors selection for parallel active filter based on the account both low-frequency and high-frequency components of the electromagnetic processes in a power circuit. Methodology. We have applied concepts of the electrical circuits theory, vector analysis, mathematical simulation in Matlab package. Results. We have developed a new technique of the phase reactors inductance selection for parallel power active filter. It allows us to obtain the smallest possible value of THD network current. Originality. We have increased accuracy of methods of the phase reactor inductance selection for power active filter. Practical value. The proposed technique can be used in the design and manufacture of the active power filter for real objects of energy supply.

  9. Effect of efficient supply of pure O{sub 2} concentrated by PSA-type O{sub 2} separator on improvement of indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Han, Gi Bo; Jang, Jung Hee; Choi, Changsik [Institute for Advanced Engineering, Yongin (Korea, Republic of); Lee, Tae Jin [School of Chemical Engineering Yeungnam University, Gyeongsan (Korea, Republic of)

    2016-04-15

    To minimize the cost and loss rate of energy artificial room ventilation system, the O{sub 2} separator was suggested for the flow of the excessive ventilation amount between indoor and outdoor because the pure O{sub 2} separated and concentrated by the O{sub 2} separator can be supplied with the ventilation amount minimized. How the O{sub 2} separator applies to ventilation and its operation characteristics were investigated by controlling under various conditions as well as the operation conditions optimized required for indoor air quality such as the concentration of CO{sub 2} and O{sub 2}. Consequently, it was known that the O{sub 2} concentration was increased; however, the increase of the CO{sub 2} concentration was suppressed by the sufficient supply of O{sub 2} concentrated from the storage tank into the room despite the two persons’ breathing in the room having an inner volume of about 56m{sup 3}. Consequently, it was concluded that the supply system of the concentrated O{sub 2} which was stored into the tank after the production with the O{sub 2} separator can be applied to the room ventilation system for the improvement of the indoor air quality.

  10. RadNet Air Data From Sacramento, CA

    Science.gov (United States)

    This page presents radiation air monitoring and air filter analysis data for Sacramento, CA from EPA's RadNet system. RadNet is a nationwide network of monitoring stations that measure radiation in air, drinking water and precipitation.

  11. RadNet Air Data From Honolulu, HI

    Science.gov (United States)

    This page presents radiation air monitoring and air filter analysis data for Honolulu, HI from EPA's RadNet system. RadNet is a nationwide network of monitoring stations that measure radiation in air, drinking water and precipitation.

  12. RadNet Air Data From Houston, TX

    Science.gov (United States)

    This page presents radiation air monitoring and air filter analysis data for Houston, TX from EPA's RadNet system. RadNet is a nationwide network of monitoring stations that measure radiation in air, drinking water and precipitation.

  13. RadNet Air Data From Austin, TX

    Science.gov (United States)

    This page presents radiation air monitoring and air filter analysis data for Austin, TX from EPA's RadNet system. RadNet is a nationwide network of monitoring stations that measure radiation in air, drinking water and precipitation.

  14. RadNet Air Data From Orlando, FL

    Science.gov (United States)

    This page presents radiation air monitoring and air filter analysis data for Orlando, FL from EPA's RadNet system. RadNet is a nationwide network of monitoring stations that measure radiation in air, drinking water and precipitation.

  15. Experience with HEPA filters at United States nuclear installations

    International Nuclear Information System (INIS)

    Bellamy, R.R.

    1977-01-01

    Part 50 of Title 10 of the United States Code of Federal Regulations requires that a number of atmosphere cleanup systems be included in the design of commercial nuclear power plants to be licensed in the United States. These filtering systems are to contain high efficiency particulate air (HEPA) filters for removal of radioactive particulate matter generated during normal and accident conditions. Recommendations for the design, testing and maintenance of the filtering systems and HEPA filter components are contained in a number of United States Nuclear Regulatory Commission documents and industry standards. This paper will discuss this published guidance available to designers of filtering systems and the plant operators of U.S. commercial nuclear power plants. The paper will also present a survey of published reports of experience with HEPA filters, failures and possible causes for the failures, and other abnormal occurrences pertaining to HEPA filters installed in U.S. nuclear power installations. A discussion will be included of U.S. practices for qualification of HEPA filters before installation, and verification of continued performance capability at scheduled intervals during operation

  16. 16th DOE nuclear air cleaning conference: proceedings

    International Nuclear Information System (INIS)

    First, M.W.

    1981-02-01

    Major topics discussed during the Sixteenth DOE Nuclear Air Cleaning Conference were: waste treatment, including volume reduction and storage; system and component response to stress and accident conditions; Three Mile Island accident; iodine adsorption; treatment and storage of noble gas: treatment of offgases from chemical processing; aerosol; behavior; containment venting; laboratory and in-place filter-testing methods; and particulate filtration. Volume I of the Proceedings has 49 papers from the following sessions; HEPA filter test methods; noble gas separation; air cleaning system design; containment venting; iodine adsorption; reprocessing offgas cleaning; critical review; filtration; filter testing; and aerosols. Volume II contains 44 papers from the sessions on: nuclear waste treatment; critical review; noble gas treatment; carbon-14 and tritium; air cleaning system response to stress; nuclear standards and safety; round table; open end; and air cleaning technology at Three Mile Island. Abstracts are provided for all of these papers

  17. 16th DOE nuclear air cleaning conference: proceedings

    International Nuclear Information System (INIS)

    First, M.W.

    1981-02-01

    Major topics discussed during the Sixteenth DOE Nuclear Air Cleaning Conference were: waste treatment, including volume reduction and storage; system and component response to stress and accident conditions; Three Mile Island accident; iodine adsorption; treatment and storage of noble gas; treatment of offgases from chemical processing; aerosol behavior; containment venting; laboratory and in-place filter-testing methods; and particulate filtration. Volume I of the Proceedings has 49 papers from the following sessions: HEPA filter test methods; noble gas separation; air cleaning system design; containment venting; iodine adsorption; reprocessing offgas cleaning; critical review; filtration, filter testing, and aerosols. Volume II contains 44 papers from the sessions on: nuclear waste treatment; critical review; noble gas treatment; carbon-14 and tritium; air cleaning system response to stress; nuclear standards and safety; round table; open end; and air cleaning technology at Three Mile Island. Abstracts are provided for all of these papers

  18. Nuclear air cleaning activities in Germany

    International Nuclear Information System (INIS)

    Wilhelm, J.

    1991-01-01

    The discussion is limited to nuclear air cleaning activities in the Federal Republic of Germany. Work is underway on containment venting with regard to filtration based on a combination of stainless steel roughing and fine filters with a decontamination factor similar to or better than that achieved with high-efficiency particulate air filters. The main point of interest is the development of relatively small filter units that can be located inside the containment. The concept of a new design for double containment having annular rooms between the steel containment and the concrete containment is discussed. Work related to the dismantling of decommissioned reactors and limited research for fuel reprocessing facilities are also noted

  19. Impact of individually controlled facially applied air movement on perceived air quality at high humidity

    DEFF Research Database (Denmark)

    Skwarczynski, Mariusz; Melikov, Arsen Krikor; Kaczmarczyk, J.

    2010-01-01

    and local air velocity under a constant air temperature of 26 degrees C, namely: 70% relative humidity without air movement, 30% relative humidity without air movement and 70% relative humidity with air movement under isothermal conditions. Personalized ventilation was used to supply room air from the front...

  20. Sampling and preparation of air pollutants at the Coal Paiton Power Plant area Probolinggo

    International Nuclear Information System (INIS)

    Iswantoro; Sutanto, W.W

    2013-01-01

    Sampling has been conducted on April 8 th to 18 th, 2012 at the plant area of Paiton Coal Power Plant using e-sampler for particulated matter PM-2,5 and PM-10, high volume air sampler for total suspended particulate (TSP) at the three sampling locations as the representative pollution. Filter before and after sampling was weighed and extremely guarded contamination. Air filters stored in desiccator filter for 24 hours. Determination of concentration of ambient air pollutants conducted by gravimetric method derived from a reduction in weight the samples on the filter PM-2,5; PM-10 and TSP to the weight of the empty filter. (author)