WorldWideScience

Sample records for supplemental breast ultrasound

  1. Potential impact of legislation mandating breast density notification: benefits, harms, and cost effectiveness of supplemental ultrasound screening

    Science.gov (United States)

    Sprague, Brian L.; Stout, Natasha K.; Schechter, Clyde; van Ravesteyn, Nicolien T.; Cevik, Mucahit; Alagoz, Oguzhan; Lee, Christoph I.; van den Broek, Jeroen J.; Miglioretti, Diana L.; Mandelblatt, Jeanne S.; de Koning, Harry J.; Kerlikowske, Karla; Lehman, Constance D.; Tosteson, Anna N. A.

    2014-01-01

    Background At least nineteen states have laws that require telling women with dense breasts and a negative screening mammogram to consider supplemental screening. The most readily available supplemental screening modality is ultrasound, yet little is known about its effectiveness. Objective To evaluate the benefits, harms, and cost-effectiveness of supplemental ultrasound screening for women with dense breasts. Design Comparative modeling with 3 validated simulation models. Data Sources Surveillance, Epidemiology, and End Results Program; Breast Cancer Surveillance Consortium; the medical literature. Target Population A contemporary cohort of women eligible for routine screening. Time Horizon Lifetime. Perspective Payer. Interventions Supplemental ultrasound screening for women with dense breasts following a negative screening mammogram. Outcome Measures Breast cancer deaths averted, quality-adjusted life years (QALYs) gained, false positive ultrasound biopsy recommendations, costs, costs per QALY gained. Results of Base-Case Analysis Supplemental ultrasound screening after a negative mammogram for women aged 50–74 with heterogeneously or extremely dense breasts averted 0.36 additional breast cancer deaths (range across models: 0.14–0.75), gained 1.7 QALYs (0.9–4.7), and resulted in 354 false-positive ultrasound biopsy recommendations (345–421) per 1000 women with dense breasts compared with biennial screening by mammography alone. The cost-effectiveness ratio was $325,000 per QALY gained ($112,000-$766,000). Restricting supplemental ultrasound screening to women with extremely dense breasts cost $246,000 per QALY gained ($74,000-$535,000). Results of Sensitivity Analysis The conclusions were not sensitive to ultrasound performance characteristics, screening frequency, or starting age. Limitations Provider costs for coordinating supplemental ultrasound were not considered. Conclusions Supplemental ultrasound screening for women with dense breasts undergoing

  2. Early detection of breast cancer: benefits and risks of supplemental breast ultrasound in asymptomatic women with mammographically dense breast tissue. A systematic review

    International Nuclear Information System (INIS)

    Nothacker, Monika; Duda, Volker; Hahn, Markus; Warm, Mathias; Degenhardt, Friedrich; Madjar, Helmut; Weinbrenner, Susanne; Albert, Ute-Susann

    2009-01-01

    Mammographic screening alone will miss a certain fraction of malignancies, as evidenced by retrospective reviews of mammograms following a subsequent screening. Mammographic breast density is a marker for increased breast cancer risk and is associated with a higher risk of interval breast cancer, i.e. cancer detected between screening tests. The purpose of this review is to estimate risks and benefits of supplemental breast ultrasound in women with negative mammographic screening with dense breast tissue. A systematic search and review of studies involving mammography and breast ultrasound for screening of breast cancer was conducted. The search was performed for the period 1/2000-8/2008 within the data source of PubMed, DARE, and Cochrane databases. Inclusion and exclusion criteria were determined prospectively, and the Oxford evidence classification system for diagnostic studies was used for evidence level. The parameters biopsy rate, positive predictive value (PPV) for biopsy, cancer yield for breast ultrasound alone, and carcinoma detection rate by breast density were extracted or constructed. The systematic search identified no randomized controlled trials or systematic reviews, six cohort studies of intermediate level of evidence (3b) were found. Only two of the studies included adequate follow-up of subjects with negative or benign findings. Supplemental breast ultrasound after negative mammographic screening permitted diagnosis of primarily invasive carcinomas in 0.32% of women in breast density type categories 2-4 of the American College of Radiology (ACR); mean tumor size for those identified was 9.9 mm, 90% with negative lymph node status. Most detected cancers occurred in mammographically dense breast ACR types 3 and 4. Biopsy rates were in the range 2.3%-4.7%, with PPV of 8.4-13.7% for those biopsied due to positive ultrasound, or about one third of the PPV of biopsies due to mammography. Limitations: The study populations included wide age ranges, and

  3. Utility of supplemental screening with breast ultrasound in asymptomatic women with dense breast tissue who are not at high risk for breast cancer

    Directory of Open Access Journals (Sweden)

    Geetika A Klevos

    2017-01-01

    Full Text Available Objective: To assess the results of an initial round of supplemental screening with hand-held bilateral breast ultrasound following a negative screening mammogram in asymptomatic women with dense breast tissue who are not at high risk for breast cancer. Materials and Methods: A retrospective, Health Insurance Portability and Accountability Act compliant, Institutional Research Board approved study was performed at a single academic tertiary breast center. Informed consent was waived. A systematic review of the breast imaging center database was conducted to identify and retrieve data for all asymptomatic women, who were found to have heterogeneously dense or extremely dense breast tissue on screening bilateral mammograms performed from July 1, 2010 through June 30, 2012 and who received a mammographic final assessment American College of Radiology's (ACR Breast Imaging Reporting and Data System (BI-RADS category 1 or BI-RADS category 2. Hand-held screening ultrasound was performed initially by a technologist followed by a radiologist. Chi-square and t-test were used and statistical significance was considered at P< 0.05. Results: A total of 1210 women were identified. Of these, 394 underwent the offered supplemental screening ultrasound. BI-RADS category 1 or 2 was assigned to 323 women (81.9%. BI-RADS category 3 was assigned to 50 women (12.9%. A total of 26 biopsies/aspirations were recommended and performed in 26 women (6.6%. The most common finding for which biopsy was recommended was a solid mass (88.5% with an average size of 0.9 cm (0.5–1.7 cm. Most frequent pathology result was fibroadenoma (60.8%. No carcinoma was found. Conclusion: Our data support the reported occurrence of a relatively high number of false positives at supplemental screening with breast ultrasound following a negative screening mammogram in asymptomatic women with dense breast tissue, who are not at a high risk of developing breast cancer, and suggests that caution

  4. Utility of supplemental screening with breast ultrasound in asymptomatic women with dense breast tissue who are not at high risk for breast cancer.

    Science.gov (United States)

    Klevos, Geetika A; Collado-Mesa, Fernando; Net, Jose M; Yepes, Monica M

    2017-01-01

    To assess the results of an initial round of supplemental screening with hand-held bilateral breast ultrasound following a negative screening mammogram in asymptomatic women with dense breast tissue who are not at high risk for breast cancer. A retrospective, Health Insurance Portability and Accountability Act compliant, Institutional Research Board approved study was performed at a single academic tertiary breast center. Informed consent was waived. A systematic review of the breast imaging center database was conducted to identify and retrieve data for all asymptomatic women, who were found to have heterogeneously dense or extremely dense breast tissue on screening bilateral mammograms performed from July 1, 2010 through June 30, 2012 and who received a mammographic final assessment American College of Radiology's (ACR) Breast Imaging Reporting and Data System (BI-RADS) category 1 or BI-RADS category 2. Hand-held screening ultrasound was performed initially by a technologist followed by a radiologist. Chi-square and t -test were used and statistical significance was considered at P ultrasound. BI-RADS category 1 or 2 was assigned to 323 women (81.9%). BI-RADS category 3 was assigned to 50 women (12.9%). A total of 26 biopsies/aspirations were recommended and performed in 26 women (6.6%). The most common finding for which biopsy was recommended was a solid mass (88.5%) with an average size of 0.9 cm (0.5-1.7 cm). Most frequent pathology result was fibroadenoma (60.8%). No carcinoma was found. Our data support the reported occurrence of a relatively high number of false positives at supplemental screening with breast ultrasound following a negative screening mammogram in asymptomatic women with dense breast tissue, who are not at a high risk of developing breast cancer, and suggests that caution is necessary in establishing wide implementation of this type of supplemental screening for all women with dense breast tissue without considering other risk factors for

  5. Utility of supplemental screening with breast ultrasound in asymptomatic women with dense breast tissue who are not at high risk for breast cancer

    OpenAIRE

    Klevos, Geetika A; Collado-Mesa, Fernando; Net, Jose M; Yepes, Monica M

    2017-01-01

    Objective: To assess the results of an initial round of supplemental screening with hand-held bilateral breast ultrasound following a negative screening mammogram in asymptomatic women with dense breast tissue who are not at high risk for breast cancer. Materials and Methods: A retrospective, Health Insurance Portability and Accountability Act compliant, Institutional Research Board approved study was performed at a single academic tertiary breast center. Informed consent was waived. A system...

  6. Dense breasts: a review of reporting legislation and available supplemental screening options.

    Science.gov (United States)

    Ho, Jessica M; Jafferjee, Nasima; Covarrubias, Gabriel M; Ghesani, Munir; Handler, Bradley

    2014-08-01

    The objectives of this article are to discuss the Mammography Quality Standards Act (MQSA) and what it means for patients, define breast density and explain how it is measured, review the new state-based legislation regarding the reporting of dense breast tissue directly to patients and the possibility of an adjunct screening examination, describe possible supplemental screening options and the advantages and disadvantages of each, and outline the current shortcomings and unanswered questions regarding new legislation. Breast density is now established as an independent risk factor for developing breast cancer irrespective of other known risk factors. Women with breast density in the upper quartile have an associated four to five times greater risk of developing breast cancer relative to women with breast density in the lower quartile. Many states have enacted or proposed legislation requiring mammographers to report to patients directly if they have dense breast tissue and recommend discussing the possibility of a supplemental screening examination with their physicians. However, there is currently no consensus as to whether a supplemental screening examination should be pursued or which modality to use. Possible supplemental screening modalities include ultrasound, MRI, digital breast tomosynthesis, and molecular breast imaging. The U.S. Food and Drug Administration recently approved an automated breast ultrasound system for screening whole-breast ultrasound in patients with dense breasts. However, many questions are still unanswered including the impact on morbidity and mortality, cost-effectiveness, and insurance coverage.

  7. Value of breast MRI as supplement to mammography and sonography for high risk breast cancer patients

    International Nuclear Information System (INIS)

    Schlossbauer, T.; Hellerhoff, K.; Reiser, M.

    2008-01-01

    The aim of this study is to give an overview on early detection of breast cancer in patients with an increased risk of breast cancer. Sensitivities and diagnostic accuracies of breast MRI, mammography and ultrasound were compared. A systematic literature search of the past 3 years was performed. Studies which compared breast imaging modalities and used image-guided biopsy results as standard of reference were included. Patients included had to have had an increased lifetime risk for breast cancer (>15%). Regarding sensitivity and diagnostic accuracy, breast MRI performed best in comparison to the other modalities within this collective of patients. Sensitivities ranged from 71-100%, 0-78%, and 13-65%, for MRI, mammography, and ultrasound, respectively Breast MRI is a well established tool for screening in patients at high risk for developing breast cancer and is a valuable supplement to mammography and ultrasound within this selected cohort of patients. (orig.) [de

  8. Breast ultrasound tomography with total-variation regularization

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Li, Cuiping [KARMANOS CANCER INSTIT.; Duric, Neb [KARMANOS CANCER INSTIT

    2009-01-01

    Breast ultrasound tomography is a rapidly developing imaging modality that has the potential to impact breast cancer screening and diagnosis. A new ultrasound breast imaging device (CURE) with a ring array of transducers has been designed and built at Karmanos Cancer Institute, which acquires both reflection and transmission ultrasound signals. To extract the sound-speed information from the breast data acquired by CURE, we have developed an iterative sound-speed image reconstruction algorithm for breast ultrasound transmission tomography based on total-variation (TV) minimization. We investigate applicability of the TV tomography algorithm using in vivo ultrasound breast data from 61 patients, and compare the results with those obtained using the Tikhonov regularization method. We demonstrate that, compared to the Tikhonov regularization scheme, the TV regularization method significantly improves image quality, resulting in sound-speed tomography images with sharp (preserved) edges of abnormalities and few artifacts.

  9. Ultrasound as an Adjunct to Mammography for Breast Cancer Screening: A Health Technology Assessment

    Science.gov (United States)

    Nikitovic-Jokic, Milica; Tu, Hong Anh; Palimaka, Stefan; Higgins, Caroline; Holubowich, Corinne

    2016-01-01

    Background Screening with mammography can detect breast cancer early, before clinical symptoms appear. Some cancers, however, are not captured with mammography screening alone. Ultrasound has been suggested as a safe adjunct screening tool that can detect breast cancers missed on mammography. We investigated the benefits, harms, cost-effectiveness, and cost burden of ultrasound as an adjunct to mammography compared with mammography alone for screening women at average risk and at high risk for breast cancer. Methods We searched Ovid MEDLINE, Ovid Embase, EBM Reviews, and the NHS Economic Evaluation Database, from January 1998 to June 2015, for evidence of effectiveness, harms, diagnostic accuracy, and cost-effectiveness. Only studies evaluating the use of ultrasound as an adjunct to mammography in the specified populations were included. We also conducted a cost analysis to estimate the costs in Ontario over the next 5 years to fund ultrasound as an adjunct to mammography in breast cancer screening for high-risk women who are contraindicated for MRI, the current standard of care to supplement mammography. Results No studies in average-risk women met the inclusion criteria of the clinical review. We included 5 prospective, paired cohort studies in high-risk women, 4 of which were relevant to the Ontario context. Adjunct ultrasound identified between 2.3 and 5.9 additional breast cancers per 1,000 screens. The average pooled sensitivity of mammography and ultrasound was 53%, a statistically significant increase relative to mammography alone (absolute increase 13%; P screening alone. The GRADE for this body of evidence was low. Additional annual costs of using breast ultrasound as an adjunct to mammography for high-risk women in Ontario contraindicated for MRI would range from $15,500 to $30,250 in the next 5 years. Conclusions We found no evidence that evaluated the comparative effectiveness or diagnostic accuracy of screening breast ultrasound as an adjunct to

  10. Ultrasound Elastography in Breast Cancer Diagnosis

    DEFF Research Database (Denmark)

    Carlsen, J.; Ewertsen, C; Sletting, S

    2015-01-01

    Ultrasound elastography is an established method for characterization of focal lesions in the breast. Different techniques and analyses of the images may be used for the characterization. This article addresses the use of ultrasound elastography in breast cancer diagnosis. In the first part...

  11. Sonomammography: An atlas of comparative breast ultrasound

    International Nuclear Information System (INIS)

    Guyer, B.P.; Dewsbury, K.C.

    1987-01-01

    This atlas of breast ultrasound is extensively illustrated and provides a short analytical text before each group of pathologies. Although based on B-scan techniques, there are numerous comparisons with sector scans and linear array scans. X-ray mammography and breast ultrasound is analyzed, based upon 2000 sonomammograms, showing how a more accurate pre-operation assessment can be made, and how unnecessary surgery can be reduced. Major features of this atlas include a detailed analysis of the appearances of breast lesions, extensive illustrations of the various pathologies (generally confirmed histologically), a close comparison of ultrasound with x-ray mammography, and illustrations of lesions by different ultrasound techniques

  12. Digital breast tomosynthesis versus mammography and breast ultrasound: a multireader performance study

    International Nuclear Information System (INIS)

    Thibault, Fabienne; Malhaire, Caroline; Tardivon, Anne; Dromain, Clarisse; Balleyguier, Corinne S.; Breucq, Catherine; Steyaert, Luc; Baldan, Enrica; Drevon, Harir

    2013-01-01

    To compare the diagnostic performance of single-view breast tomosynthesis (BT) with that of dual-view mammography (MX); to assess the benefit of adding the craniocaudal (CC) mammographic view to BT, and of adding BT to MX plus breast ultrasound, considered to be the reference work-up. One hundred and fifty-five consenting patients with unresolved mammographic and/or ultrasound findings or breast symptoms underwent conventional work-up plus mediolateral oblique-view BT of the affected breast. The final study set in 130 patients resulted in 55 malignant and 76 benign and normal cases. Seven breast radiologists rated the cases through five sequential techniques using a BIRADS-based scale: MX, MX + ultrasound, MX + ultrasound + BT, BT, BT + MX(CC). Multireader, multicase receiver operating characteristic (ROC) analysis was performed and performance of the techniques was assessed from the areas under ROC curves. The performance of BT and of BT + MX(CC) was tested versus MX; the performance of MX + ultrasound + BT tested versus MX + ultrasound. Tomosynthesis was found to be non-inferior to mammography. BT + MX(CC) did not appear to be superior to MX, and MX + ultrasound + BT not superior to MX + ultrasound. Overall, none of the five techniques tested outperformed the others. Further clinical studies are needed to clarify the role of BT as a substitute for traditional work-up in the diagnostic environment. (orig.)

  13. Patient awareness of breast density and interest in supplemental screening tests: comparison of an academic facility and a county hospital.

    Science.gov (United States)

    Trinh, Long; Ikeda, Debra M; Miyake, Kanae K; Trinh, Jennifer; Lee, Kevin K; Dave, Haatal; Hanafusa, Kei; Lipson, Jafi

    2015-03-01

    The aim of this study was to measure women's knowledge of breast density and their attitudes toward supplemental screening tests in the setting of the California Breast Density Notification Law at an academic facility and a county hospital, serving women with higher and lower socioeconomic status, respectively. Institutional review board exemptions were obtained. A survey was administered during screening mammography at two facilities, assessing women's awareness of and interest in knowing their breast density and interest in and willingness to pay for supplemental whole breast ultrasound and contrast-enhanced spectral mammography (CEMG). The results were compared by using Fisher exact tests between groups. A total of 105 of 130 and 132 of 153 women responded to the survey at the academic and county facilities, respectively. Among respondents at the academic and county facilities, 23% and 5% were aware of their breast density, and 94% and 79% wanted to know their density. A majority were interested in supplemental ultrasonography and CEMG at both sites; however, fewer women had a willingness to pay for the supplemental tests at the county hospital compared with those at the academic facility (22% and 70%, respectively, for ultrasound, P women were interested in knowing their breast density and in supplemental screening tests. However, women at the county hospital were less willing to incur out-of-pocket expenses, suggesting a potential for a disparity in health care access for women of lower socioeconomic status after the enactment of breast density notification legislation. Published by Elsevier Inc.

  14. Ultrasound screening of contralateral breast after surgery for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ja [Department of Radiology, Seoul Metropolitan Government Seoul National University, Boramae Medical Center (Korea, Republic of); Chung, Se-Yeong; Chang, Jung Min; Cho, Nariya [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Han, Wonshik [Department of Surgery, Seoul National University Hospital (Korea, Republic of); Moon, Woo Kyung, E-mail: moonwk@snu.ac.kr [Department of Radiology, Seoul National University Hospital (Korea, Republic of)

    2015-01-15

    Highlights: • The addition of supplemental US to mammography depicted additional 5.0 cancers per 1000 postoperative women. • Positive biopsy rate of mammography-detected lesions was 66.7% (4 of 6) and that of US-detected lesions was 40.0% (6 of 15). • US can be helpful to detect mammographically occult breast cancer in the contralateral breast in women with previous history of cancer and dense breast. - Abstract: Objective: To determine whether supplemental screening ultrasound (US) to mammography could improve cancer detection rate of the contralateral breast in patients with a personal history of breast cancer and dense breasts. Materials and methods: During a one-year study period, 1314 screening patients with a personal history of breast cancer and dense breasts simultaneously underwent mammography and breast US. BI-RADS categories were given for mammography or US-detected lesions in the contralateral breast. The reference standard was histology and/or 1-year imaging follow-up, and the cancer rate according to BI-RADS categories and cancer detection rate and positive biopsy rate according to detection modality were analyzed. Results: Of 1314 patients, 84 patients (6.4%) were categorized as category 3 with one interval cancer and one cancer which was upgraded to category 4A after 6-month follow-up US (2.5% cancer rate, 95% CIs 1.5–9.1%). Fifteen patients (1.1%) had category 4A or 4B lesions in the contralateral breast. Four lesions were detected on mammography (two lesions were also visible on US) and 11 lesions were detected on US and 5 cancers were confirmed (33.3%, 95% CIs 15.0–58.5%). Six patients (0.5%) had category 4C lesions, 2 detected on mammography and 4 on US and 4 cancers were confirmed (66.7%, 95% CIs 29.6–90.8%). No lesions were categorized as category 5 in the contralateral breast. Cancer detection rate by mammography was 3.3 per 1000 patients and that by US was 5.0 per 1000 patients, therefore overall cancer detection rate by

  15. Ultrasound screening of contralateral breast after surgery for breast cancer

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Chung, Se-Yeong; Chang, Jung Min; Cho, Nariya; Han, Wonshik; Moon, Woo Kyung

    2015-01-01

    Highlights: • The addition of supplemental US to mammography depicted additional 5.0 cancers per 1000 postoperative women. • Positive biopsy rate of mammography-detected lesions was 66.7% (4 of 6) and that of US-detected lesions was 40.0% (6 of 15). • US can be helpful to detect mammographically occult breast cancer in the contralateral breast in women with previous history of cancer and dense breast. - Abstract: Objective: To determine whether supplemental screening ultrasound (US) to mammography could improve cancer detection rate of the contralateral breast in patients with a personal history of breast cancer and dense breasts. Materials and methods: During a one-year study period, 1314 screening patients with a personal history of breast cancer and dense breasts simultaneously underwent mammography and breast US. BI-RADS categories were given for mammography or US-detected lesions in the contralateral breast. The reference standard was histology and/or 1-year imaging follow-up, and the cancer rate according to BI-RADS categories and cancer detection rate and positive biopsy rate according to detection modality were analyzed. Results: Of 1314 patients, 84 patients (6.4%) were categorized as category 3 with one interval cancer and one cancer which was upgraded to category 4A after 6-month follow-up US (2.5% cancer rate, 95% CIs 1.5–9.1%). Fifteen patients (1.1%) had category 4A or 4B lesions in the contralateral breast. Four lesions were detected on mammography (two lesions were also visible on US) and 11 lesions were detected on US and 5 cancers were confirmed (33.3%, 95% CIs 15.0–58.5%). Six patients (0.5%) had category 4C lesions, 2 detected on mammography and 4 on US and 4 cancers were confirmed (66.7%, 95% CIs 29.6–90.8%). No lesions were categorized as category 5 in the contralateral breast. Cancer detection rate by mammography was 3.3 per 1000 patients and that by US was 5.0 per 1000 patients, therefore overall cancer detection rate by

  16. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  17. How accurate is ultrasound in evaluating palpable breast masses ...

    African Journals Online (AJOL)

    Methods: Eighty palpable breast masses were evaluated at ultrasound and information about the characteristic features of the masses was recorded. An impression about the diagnosis was made and results were correlated with histology findings. Results: The overall sensitivity of ultrasound in detecting breast lumps was ...

  18. Interobserver variability of ultrasound elastography and the ultrasound BI-RADS lexicon of breast lesions.

    Science.gov (United States)

    Park, Chang Suk; Kim, Sung Hun; Jung, Na Young; Choi, Jae Jung; Kang, Bong Joo; Jung, Hyun Seouk

    2015-03-01

    Elastographpy is a newly developed noninvasive imaging technique that uses ultrasound (US) to evaluate tissue stiffness. The interpretation of the same elastographic images may be variable according to reviewers. Because breast lesions are usually reported according to American College of Radiology Breast Imaging and Data System (ACR BI-RADS) lexicons and final category, we tried to compare observer variability between lexicons and final categorization of US BI-RADS and the elasticity score of US elastography. From April 2009 to February 2010, 1356 breast lesions in 1330 patients underwent ultrasound-guided core biopsy. Among them, 63 breast lesions in 55 patients (mean age, 45.7 years; range, 21-79 years) underwent both conventional ultrasound and elastography and were included in this study. Two radiologists independently performed conventional ultrasound and elastography, and another three observers reviewed conventional ultrasound images and elastography videos. Observers independently recorded the elasticity score for a 5-point scoring system proposed by Itoh et al., BI-RADS lexicons and final category using ultrasound BI-RADS. The histopathologic results were obtained and used as the reference standard. Interobserver variability was evaluated. Of the 63 lesions, 42 (66.7 %) were benign, and 21 (33.3 %) were malignant. The highest value of concordance among all variables was achieved for the elasticity score (k = 0.59), followed by shape (k = 0.54), final category (k = 0.48), posterior acoustic features (k = 0.44), echogenecity and orientation (k = 0.43). The least concordances were margin (k = 0.26), lesion boundary (k = 0.29) and calcification (k = 0.3). Elasticity score showed a higher level of interobserver agreement for the diagnosis of breast lesions than BI-RADS lexicons and final category.

  19. Breast cancer screening in Korean woman with dense breast tissue

    International Nuclear Information System (INIS)

    Shin, Hee Jung; Ko, Eun Sook; Yi, Ann

    2015-01-01

    Asian women, including Korean, have a relatively higher incidence of dense breast tissue, compared with western women. Dense breast tissue has a lower sensitivity for the detection of breast cancer and a higher relative risk for breast cancer, compared with fatty breast tissue. Thus, there were limitations in the mammographic screening for women with dense breast tissue, and many studies for the supplemental screening methods. This review included appropriate screening methods for Korean women with dense breasts. We also reviewed the application and limitation of supplemental screening methods, including breast ultrasound, digital breast tomosynthesis, and breast magnetic resonance imaging; and furthermore investigated the guidelines, as well as the study results

  20. Breast cancer screening in Korean woman with dense breast tissue

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hee Jung [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Ko, Eun Sook [Dept. of Radiology, Sungkyunkwan University School of Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Yi, Ann [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-11-15

    Asian women, including Korean, have a relatively higher incidence of dense breast tissue, compared with western women. Dense breast tissue has a lower sensitivity for the detection of breast cancer and a higher relative risk for breast cancer, compared with fatty breast tissue. Thus, there were limitations in the mammographic screening for women with dense breast tissue, and many studies for the supplemental screening methods. This review included appropriate screening methods for Korean women with dense breasts. We also reviewed the application and limitation of supplemental screening methods, including breast ultrasound, digital breast tomosynthesis, and breast magnetic resonance imaging; and furthermore investigated the guidelines, as well as the study results.

  1. An Evaluation of Ultrasound Features of Breast Fibroadenoma

    Science.gov (United States)

    Namazi, Alireza; Adibi, Atoosa; Haghighi, Mahshid; Hashemi, Morteza

    2017-01-01

    Background: Breast cancer is among the most common cancers in the world. Ultrasound evaluations of breast have come into attention as an alternative route. Ultrasound features of benign lesions such as fibroadenoma can be overlapping with those in a malignant tumor. Here, we assessed the reports of breast ultrasound in patients with pathologic diagnosis of fibroadenoma. Materials and Methods: We conducted a cross-sectional study and enrolled female patients with confirmed histologic diagnosis of fibroadenoma. Ultrasound studies were performed on the participants to see which sonographic patterns are more frequent in such lesions. Results: In 92 patients with 40.4 ± 9.2 years of age, all participants were classified as stage 4 on Breast Imaging-Reporting and Data System scale. The mean ± standard deviation of size for the lesions was 167.4 ± 101.4 mm2. Upper outer quadrants in the breasts had the most number of lesions. Almost lesions were round with only 2.2% were oval. When assessed for the margin definition, 57.8% were circumscribed. Noncircumscribed masses were reported in 21.7%. About 91.3% of cases were hypoechoic in the ultrasound evaluation. Lobulated masses were in 28.3% of the cases. 8.7% of the masses were spongy whereas 9.8% and 2.2% of them had calcification and heterogenic appearance, respectively. Conclusion: The most frequent features include a hypoechoic mass with a circumscribed border; however, complex presentations that overlap malignant masses are also detectable including noncircumscribed margin, lobulation, presence of a posterior shadow, heterogenicity, and micro calcification. PMID:29285483

  2. An Evaluation of Ultrasound Features of Breast Fibroadenoma

    Directory of Open Access Journals (Sweden)

    Alireza Namazi

    2017-01-01

    Full Text Available Background: Breast cancer is among the most common cancers in the world. Ultrasound evaluations of breast have come into attention as an alternative route. Ultrasound features of benign lesions such as fibroadenoma can be overlapping with those in a malignant tumor. Here, we assessed the reports of breast ultrasound in patients with pathologic diagnosis of fibroadenoma. Materials and Methods: We conducted a cross-sectional study and enrolled female patients with confirmed histologic diagnosis of fibroadenoma. Ultrasound studies were performed on the participants to see which sonographic patterns are more frequent in such lesions. Results: In 92 patients with 40.4 ± 9.2 years of age, all participants were classified as stage 4 on Breast Imaging-Reporting and Data System scale. The mean ± standard deviation of size for the lesions was 167.4 ± 101.4 mm2. Upper outer quadrants in the breasts had the most number of lesions. Almost lesions were round with only 2.2% were oval. When assessed for the margin definition, 57.8% were circumscribed. Noncircumscribed masses were reported in 21.7%. About 91.3% of cases were hypoechoic in the ultrasound evaluation. Lobulated masses were in 28.3% of the cases. 8.7% of the masses were spongy whereas 9.8% and 2.2% of them had calcification and heterogenic appearance, respectively. Conclusion: The most frequent features include a hypoechoic mass with a circumscribed border; however, complex presentations that overlap malignant masses are also detectable including noncircumscribed margin, lobulation, presence of a posterior shadow, heterogenicity, and micro calcification.

  3. Ultrasound elastography as an objective diagnostic measurement tool for lymphoedema of the treated breast in breast cancer patients following breast conserving surgery and radiotherapy

    International Nuclear Information System (INIS)

    Adriaenssens, Nele; Belsack, Dries; Buyl, Ronald; Ruggiero, Leonardo; Breucq, Catherine; De Mey, Johan; Lievens, Pierre; Lamote, Jan

    2012-01-01

    Lymphoedema of the operated and irradiated breast is a common complication following early breast cancer treatment. There is no consensus on objective diagnostic criteria and standard measurement tools. This study investigates the use of ultrasound elastography as an objective quantitative measurement tool for the diagnosis of parenchymal breast oedema. The elasticity ratio of the subcutis, measured with ultrasound elastography, was compared with high-frequency ultrasound parameters and subjective symptoms in twenty patients, bilaterally, prior to and following breast conserving surgery and breast irradiation. Elasticity ratio of the subcutis of the operated breast following radiation therapy increased in 88.9% of patients, was significantly higher than prior to surgery, unlike the non operated breast and significantly higher than the non operated breast, unlike preoperative results. These results were significantly correlated with visibility of the echogenic line, measured with high-frequency ultrasound. Big preoperative bra cup size was a significant risk factor for the development of breast oedema. Ultrasound elastography is an objective quantitative measurement tool for the diagnosis of parenchymal breast oedema, in combination with other objective diagnostic criteria. Further research with longer follow-up and more patients is necessary to confirm our findings

  4. Errors and mistakes in breast ultrasound diagnostics

    Directory of Open Access Journals (Sweden)

    Wiesław Jakubowski

    2012-09-01

    Full Text Available Sonomammography is often the first additional examination performed in the diagnostics of breast diseases. The development of ultrasound imaging techniques, particularly the introduction of high frequency transducers, matrix transducers, harmonic imaging and finally, elastography, influenced the improvement of breast disease diagnostics. Neverthe‑ less, as in each imaging method, there are errors and mistakes resulting from the techni‑ cal limitations of the method, breast anatomy (fibrous remodeling, insufficient sensitivity and, in particular, specificity. Errors in breast ultrasound diagnostics can be divided into impossible to be avoided and potentially possible to be reduced. In this article the most frequently made errors in ultrasound have been presented, including the ones caused by the presence of artifacts resulting from volumetric averaging in the near and far field, artifacts in cysts or in dilated lactiferous ducts (reverberations, comet tail artifacts, lateral beam artifacts, improper setting of general enhancement or time gain curve or range. Errors dependent on the examiner, resulting in the wrong BIRADS‑usg classification, are divided into negative and positive errors. The sources of these errors have been listed. The methods of minimization of the number of errors made have been discussed, includ‑ ing the ones related to the appropriate examination technique, taking into account data from case history and the use of the greatest possible number of additional options such as: harmonic imaging, color and power Doppler and elastography. In the article examples of errors resulting from the technical conditions of the method have been presented, and those dependent on the examiner which are related to the great diversity and variation of ultrasound images of pathological breast lesions.

  5. 2D/ 3D Quantitative Ultrasound of the Breast

    Science.gov (United States)

    Nasief, Haidy Gerges

    Breast cancer is the second leading cause of cancer death of women in the United States, so breast cancer screening for early detection is common. The purpose of this dissertation is to optimize quantitative ultrasound (QUS) methods to improve the specificity and objectivity of breast ultrasound. To pursue this goal, the dissertation is divided into two parts: 1) to optimize 2D QUS, and 2) to introduce and validate 3D QUS. Previous studies had validated these methods in phantoms. Applying our QUS analysis on subcutaneous breast fat demonstrated that QUS parameter estimates for subcutaneous fat were consistent among different human subjects. This validated our in vivo data acquisition methods and supported the use of breast fat as a clinical reference tissue for ultrasound BI-RADSRTM assessments. Although current QUS methods perform well for straightforward cases when assumptions of stationarity and diffuse scattering are well-founded, these conditions often are not present due to the complicated nature of in vivo breast tissue. Key improvements in QUS algorithms to address these challenges were: 1) applying a "modified least squares method (MLSM)" to account for the heterogeneous tissue path between the transducer and the region of interest, ROI; 2) detecting anisotropy in acoustic parameters; and 3) detecting and removing the echo sources that depart from diffuse and stationary scattering conditions. The results showed that a Bayesian classifier combining three QUS parameters in a biased pool of high-quality breast ultrasound data successfully differentiated all fibroadenomas from all carcinomas. Given promising initial results in 2D, extension to 3D acquisitions in QUS provided a unique capability to test QUS for the entire breast volume. QUS parameter estimates using 3D data were consistent with those found in 2D for phantoms and in vivo data. Extensions of QUS technology from 2D to 3D can improve the specificity of breast ultrasound, and thus, could lead to

  6. Ultrasound as a secondary screening tool in mammographically dense breasts

    International Nuclear Information System (INIS)

    Griggs, Kylie

    2006-01-01

    It is well known that breast screening is a part of our society and is designed to reduce the mortality and morbidity from breast cancer. Mammography is the imaging modality of choice in a breast-screening environment. Both the detection rate of mammography in a screening environment and the sensitivity of mammography in symptomatic women are known to be greater than that of ultrasound. However, after a review of literature both of these are said to increase when the two imaging modalities are combined. This paper will present that mammography has limitations in breast imaging, especially in women with dense breasts and that ultrasound can have a benefit as a secondary screening tool in these women. It will be shown that although ultrasound also has its limitations, these can be minimised with the implementation of effective education and imaging protocols. The paper will conclude that although further research into ultrasound as screening tool is required, its use as a complement to mammography can only be of benefit to the general population

  7. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    Science.gov (United States)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  8. Spectrophotometer and ultrasound evaluation of late toxicity following breast-cancer radiotherapy.

    Science.gov (United States)

    Yoshida, E J; Chen, H; Torres, M A; Curran, W J; Liu, T

    2011-10-01

    Radiation-induced normal-tissue toxicities are common, complex, and distressing side effects that affect 90% of patients receiving breast-cancer radiotherapy and 40% of patients post radiotherapy. In this study, the authors investigated the use of spectrophotometry and ultrasound to quantitatively measure radiation-induced skin discoloration and subcutaneous-tissue fibrosis. The study's purpose is to determine whether skin discoloration correlates with the development of fibrosis in breast-cancer radiotherapy. Eighteen breast-cancer patients were enrolled in our initial study. All patients were previously treated with a standard course of radiation, and the median follow-up time was 22 months. The treated and untreated breasts were scanned with a spectrophotometer and an ultrasound. Two spectrophotometer parameters-melanin and erythema indices-were used to quantitatively assess skin discoloration. Two ultrasound parameters-skin thickness and Pearson coefficient of the hypodermis-were used to quantitatively assess severity of fibrosis. These measurements were correlated with clinical assessments (RTOG late morbidity scores). Significant measurement differences between the treated and contralateral breasts were observed among all patients: 27.3% mean increase in skin thickness (p spectrophotometer parameters do not correlate with ultrasound parameters. Spectrophotometry and quantitative ultrasound are objective tools that assess radiation-induced tissue injury. Spectrophotometer parameters did not correlate with those of quantitative ultrasound suggesting that skin discoloration cannot be used as a marker for subcutaneous fibrosis. These tools may prove useful for the reduction of radiation morbidities and improvement of patient quality of life.

  9. Computerized detection of breast cancer on automated breast ultrasound imaging of women with dense breasts

    International Nuclear Information System (INIS)

    Drukker, Karen; Sennett, Charlene A.; Giger, Maryellen L.

    2014-01-01

    Purpose: Develop a computer-aided detection method and investigate its feasibility for detection of breast cancer in automated 3D ultrasound images of women with dense breasts. Methods: The HIPAA compliant study involved a dataset of volumetric ultrasound image data, “views,” acquired with an automated U-Systems Somo•V ® ABUS system for 185 asymptomatic women with dense breasts (BI-RADS Composition/Density 3 or 4). For each patient, three whole-breast views (3D image volumes) per breast were acquired. A total of 52 patients had breast cancer (61 cancers), diagnosed through any follow-up at most 365 days after the original screening mammogram. Thirty-one of these patients (32 cancers) had a screening-mammogram with a clinically assigned BI-RADS Assessment Category 1 or 2, i.e., were mammographically negative. All software used for analysis was developed in-house and involved 3 steps: (1) detection of initial tumor candidates, (2) characterization of candidates, and (3) elimination of false-positive candidates. Performance was assessed by calculating the cancer detection sensitivity as a function of the number of “marks” (detections) per view. Results: At a single mark per view, i.e., six marks per patient, the median detection sensitivity by cancer was 50.0% (16/32) ± 6% for patients with a screening mammogram-assigned BI-RADS category 1 or 2—similar to radiologists’ performance sensitivity (49.9%) for this dataset from a prior reader study—and 45.9% (28/61) ± 4% for all patients. Conclusions: Promising detection sensitivity was obtained for the computer on a 3D ultrasound dataset of women with dense breasts at a rate of false-positive detections that may be acceptable for clinical implementation

  10. Quantitative shear wave ultrasound elastography: initial experience in solid breast masses

    OpenAIRE

    Evans, Andrew; Whelehan, Patsy; Thomson, Kim; McLean, Denis; Brauer, Katrin; Purdie, Colin; Jordan, Lee; Baker, Lee; Thompson, Alastair

    2010-01-01

    Introduction Shear wave elastography is a new method of obtaining quantitative tissue elasticity data during breast ultrasound examinations. The aims of this study were (1) to determine the reproducibility of shear wave elastography (2) to correlate the elasticity values of a series of solid breast masses with histological findings and (3) to compare shear wave elastography with greyscale ultrasound for benign/malignant classification. Methods Using the Aixplorer® ultrasound system (SuperSoni...

  11. Chest wall segmentation in automated 3D breast ultrasound scans.

    Science.gov (United States)

    Tan, Tao; Platel, Bram; Mann, Ritse M; Huisman, Henkjan; Karssemeijer, Nico

    2013-12-01

    In this paper, we present an automatic method to segment the chest wall in automated 3D breast ultrasound images. Determining the location of the chest wall in automated 3D breast ultrasound images is necessary in computer-aided detection systems to remove automatically detected cancer candidates beyond the chest wall and it can be of great help for inter- and intra-modal image registration. We show that the visible part of the chest wall in an automated 3D breast ultrasound image can be accurately modeled by a cylinder. We fit the surface of our cylinder model to a set of automatically detected rib-surface points. The detection of the rib-surface points is done by a classifier using features representing local image intensity patterns and presence of rib shadows. Due to attenuation of the ultrasound signal, a clear shadow is visible behind the ribs. Evaluation of our segmentation method is done by computing the distance of manually annotated rib points to the surface of the automatically detected chest wall. We examined the performance on images obtained with the two most common 3D breast ultrasound devices in the market. In a dataset of 142 images, the average mean distance of the annotated points to the segmented chest wall was 5.59 ± 3.08 mm. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Non-Thermal High-Intensity Focused Ultrasound for Breast Cancer Therapy

    Science.gov (United States)

    2013-07-01

    Comet assay reveals DNA strand breaks induced by ultrasonic cavitation in vitro, Ultrasound in medicine & biology 1995; 21: 841-8. 3. Dalecki D...doxorubicin, focused ultrasound , HIFU, prostate cancer I. INTRODUCTION Pulsed high-intensity focused ultrasound (pFUS) is able to create acoustic cavitation ... ultrasound for breast cancer therapy PRINCIPAL INVESTIGATOR: Chang Ming (Charlie) Ma, Ph.D

  13. Breast tumor size assessment: comparison of conventional ultrasound and contrast-enhanced ultrasound.

    Science.gov (United States)

    Jiang, Yu-Xin; Liu, He; Liu, Ji-Bin; Zhu, Qing-Li; Sun, Qiang; Chang, Xiao-Yan

    2007-12-01

    Accurate assessment of tumor size is necessary when selecting patients for breast-conserving surgery. In the study of breast contrast-enhanced ultrasound (CEUS), we found that tumor size discrepancy between CEUS and conventional ultrasound (US) existed in some breast lesions, for which the reasons are not clear. Breast CEUS examinations were performed in 104 patients with breast lesions. The measurement of the 104 breast tumors on conventional US was obtained and compared with the measurement on CEUS. A difference in measuring tumor size of >3 mm for tumors up to 1.7 cm and 4 mm for tumors >or=1.7 cm, was defined as a significant discrepancy between conventional US and CEUS. The histopathological examination of size discrepancy was performed and the margin characteristics of breast cancers with larger measurements were compared with those with unchanged measurements. Among the 104 lesions (43 malignant, 60 benign, 1 borderline), the size of 27 breast cancers and one granulomatous mastitis appeared larger at CEUS. Pathologic examinations of the region corresponding to the measurement discrepancy were mainly ductal carcinomas in situ (DCIS), invasive carcinoma with a DCIS component, adenosis with lobular hyperplasia in breast cancers and inflammatory cell infiltration in one granulomatous mastitis. Well-defined margin characteristics were significantly different between breast cancers with larger measurements at CEUS and those with unchanged measurements of size (p = 0.002), whereas no significant difference was found between the two groups in ill-defined, spiculated, hyperechoic halo, microlobulated and angulated margins (p = 0.463, 0.117, 0.194, 0.666 and 0.780, respectively). This initial study suggests that significant discrepancy of breast lesion measurement between conventional US and CEUS is more likely presented in breast cancer than benign lesions. The pathologic findings corresponding to the region of size increased at CEUS are malignant in most malignant

  14. Performance of hand-held whole-breast ultrasound based on BI-RADS in women with mammographically negative dense breast

    International Nuclear Information System (INIS)

    Youk, Ji Hyun; Kim, Eun-Kyung; Kim, Min Jung; Kwak, Jin Young; Son, Eun Ju

    2011-01-01

    To assess the performance of breast ultrasound based on BI-RADS final assessment categories in women with mammographically negative dense breast. Of 3,820 cases with mammographically negative dense breast and subsequent hand-held bilateral whole-breast ultrasound, a total of 1,507 cases in 1,046 women who had biopsy or at least 2-year follow-up ultrasound constituted the basis of this retrospective study. Cancer rate of each sonographic BI-RADS category was determined and medical audit was performed separately in screening-general, screening-treated, and diagnostic group. A total of 43 cases (2.9%) were confirmed as malignancy. Cancer rate among BI-RADS categories was significantly different (p < 0.0001). Among three groups, the cancer rate was significantly different (p < 0.0001) and the highest in diagnostic group (15.8%, 22 of 139). Abnormal interpretation rate, PPV of biopsy performed, cancer detection rate, and rate of early stage cancer, and the size of invasive cancer were significantly different among three groups and the highest in diagnostic group. Regarding cancer characteristics, the proportion of advanced cancer was the highest in diagnostic group. Breast ultrasound based on BI-RADS as an adjunctive to negative mammography can be useful for predicting malignancy in women with dense breast. (orig.)

  15. Preliminary Clinical Experience with a Combined Automated Breast Ultrasound and Digital Breast Tomosynthesis System.

    Science.gov (United States)

    Larson, Eric D; Lee, Won-Mean; Roubidoux, Marilyn A; Goodsitt, Mitchell M; Lashbrook, Chris; Davis, Cynthia E; Kripfgans, Oliver D; Carson, Paul L

    2018-03-01

    We analyzed the performance of a mammographically configured, automated breast ultrasound (McABUS) scanner combined with a digital breast tomosynthesis (DBT) system. The GE Invenia ultrasound system was modified for integration with GE DBT systems. Ultrasound and DBT imaging were performed in the same mammographic compression. Our small preliminary study included 13 cases, six of whom had contained invasive cancers. From analysis of these cases, current limitations and corresponding potential improvements of the system were determined. A registration analysis was performed to compare the ease of McABUS to DBT registration for this system with that of two systems designed previously. It was observed that in comparison to data from an earlier study, the McABUS-to-DBT registration alignment errors for both this system and a previously built combined system were smaller than those for a previously built standalone McABUS system. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  16. Initial results of the FUSION-X-US prototype combining 3D automated breast ultrasound and digital breast tomosynthesis.

    Science.gov (United States)

    Schaefgen, Benedikt; Heil, Joerg; Barr, Richard G; Radicke, Marcus; Harcos, Aba; Gomez, Christina; Stieber, Anne; Hennigs, André; von Au, Alexandra; Spratte, Julia; Rauch, Geraldine; Rom, Joachim; Schütz, Florian; Sohn, Christof; Golatta, Michael

    2018-06-01

    To determine the feasibility of a prototype device combining 3D-automated breast ultrasound (ABVS) and digital breast tomosynthesis in a single device to detect and characterize breast lesions. In this prospective feasibility study, the FUSION-X-US prototype was used to perform digital breast tomosynthesis and ABVS in 23 patients with an indication for tomosynthesis based on current guidelines after clinical examination and standard imaging. The ABVS and tomosynthesis images of the prototype were interpreted separately by two blinded experts. The study compares the detection and BI-RADS® scores of breast lesions using only the tomosynthesis and ABVS data from the FUSION-X-US prototype to the results of the complete diagnostic workup. Image acquisition and processing by the prototype was fast and accurate, with some limitations in ultrasound coverage and image quality. In the diagnostic workup, 29 solid lesions (23 benign, including three cases with microcalcifications, and six malignant lesions) were identified. Using the prototype, all malignant lesions were detected and classified as malignant or suspicious by both investigators. Solid breast lesions can be localized accurately and fast by the Fusion-X-US system. Technical improvements of the ultrasound image quality and ultrasound coverage are needed to further study this new device. The prototype combines tomosynthesis and automated 3D-ultrasound (ABVS) in one device. It allows accurate detection of malignant lesions, directly correlating tomosynthesis and ABVS data. The diagnostic evaluation of the prototype-acquired data was interpreter-independent. The prototype provides a time-efficient and technically reliable diagnostic procedure. The combination of tomosynthesis and ABVS is a promising diagnostic approach.

  17. Detecting breast microcalcifications using super-resolution and wave-equation ultrasound imaging: a numerical phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Simonetti, Francesco [IMPERIAL COLLEGE LONDON; Huthwaite, Peter [IMPERIAL COLLEGE LONDON; Rosenberg, Robert [UNM; Williamson, Michael [UNM

    2010-01-01

    Ultrasound image resolution and quality need to be significantly improved for breast microcalcification detection. Super-resolution imaging with the factorization method has recently been developed as a promising tool to break through the resolution limit of conventional imaging. In addition, wave-equation reflection imaging has become an effective method to reduce image speckles by properly handling ultrasound scattering/diffraction from breast heterogeneities during image reconstruction. We explore the capabilities of a novel super-resolution ultrasound imaging method and a wave-equation reflection imaging scheme for detecting breast microcalcifications. Super-resolution imaging uses the singular value decomposition and a factorization scheme to achieve an image resolution that is not possible for conventional ultrasound imaging. Wave-equation reflection imaging employs a solution to the acoustic-wave equation in heterogeneous media to backpropagate ultrasound scattering/diffraction waves to scatters and form images of heterogeneities. We construct numerical breast phantoms using in vivo breast images, and use a finite-difference wave-equation scheme to generate ultrasound data scattered from inclusions that mimic microcalcifications. We demonstrate that microcalcifications can be detected at full spatial resolution using the super-resolution ultrasound imaging and wave-equation reflection imaging methods.

  18. MR-Guided High-Intensity Focused Ultrasound Ablation of Breast Cancer with a Dedicated Breast Platform

    International Nuclear Information System (INIS)

    Merckel, Laura G.; Bartels, Lambertus W.; Köhler, Max O.; Bongard, H. J. G. Desirée van den; Deckers, Roel; Mali, Willem P. Th. M.; Binkert, Christoph A.; Moonen, Chrit T.; Gilhuijs, Kenneth G. A.; Bosch, Maurice A. A. J. van den

    2013-01-01

    Optimizing the treatment of breast cancer remains a major topic of interest. In current clinical practice, breast-conserving therapy is the standard of care for patients with localized breast cancer. Technological developments have fueled interest in less invasive breast cancer treatment. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a completely noninvasive ablation technique. Focused beams of ultrasound are used for ablation of the target lesion without disrupting the skin and subcutaneous tissues in the beam path. MRI is an excellent imaging method for tumor targeting, treatment monitoring, and evaluation of treatment results. The combination of HIFU and MR imaging offers an opportunity for image-guided ablation of breast cancer. Previous studies of MR-HIFU in breast cancer patients reported a limited efficacy, which hampered the clinical translation of this technique. These prior studies were performed without an MR-HIFU system specifically developed for breast cancer treatment. In this article, a novel and dedicated MR-HIFU breast platform is presented. This system has been designed for safe and effective MR-HIFU ablation of breast cancer. Furthermore, both clinical and technical challenges are discussed, which have to be solved before MR-HIFU ablation of breast cancer can be implemented in routine clinical practice.

  19. The Role of Breast Ultrasound in Early Cancer Detection

    Directory of Open Access Journals (Sweden)

    Huay-Ben Pan

    2016-12-01

    Full Text Available Ultrasonography (US is currently considered the first-line examination in the detection and characterization of breast lesions including the evaluation of breast cancer. Yet only few single-center cohort studies analyzing breast US in the framework of screening could be identified. In spite of mammography consider as the primary method for screening especially the noteworthy ability of microcalcifications detection. US is good in mass or mass- like lesion detection, especially in the dense breast population that proved by the study of ACRIN 6666. A lobular hypoechoic area; lesion with ductal extension and dilatation; and a hypoechoic nodular lesion with a dilated lactiferous duct leading to the retroareolar region, that were the common ultrasound findings in Ductal carcinoma in situ (DCIS and probably related to nuclear grade of cancer. Computer programs have been developed and approved for use in clinical practice, the application including CAD (computer aided/assisted detection/diagnosis, ABUS (automated breast US, elastography and microbubbles in contrast-enhanced ultrasound. Furthermore the standardized scanning; improving with computer technology implementation and familiar to the picture of DCIS is necessary for progress the competence of early breast cancer detection.

  20. Mammography and ultrasound in the evaluation of male breast disease

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Carrasco, Rafaela; Alvarez Benito, Marina; Raya Povedano, Jose Luis [Hospital Universitario ' Reina Sofia' , Radiology Department, Cordoba (Spain); Munoz Gomariz, Elisa [Hospital Universitario ' Reina Sofia' , Support Unit for Research, Cordoba (Spain); Martinez Paredes, Maria [University of Cordoba, Radiology and Physical Medicine Area, Cordoba (Spain)

    2010-12-15

    To assess clinical variables that may be useful in differentiating gynaecomastia from carcinoma and to analyse the contribution of mammography and ultrasound to the evaluation of male breast disease. All men who underwent mammography and/or ultrasound between 1993 and 2006 in our hospital were retrospectively evaluated. Clinical characteristics in patients with gynaecomastia and those with carcinoma were compared. Radiological findings were classified according to the BI-RADS (Breast Imaging Reporting and Data System) criteria. The diagnostic performance of physical examination, mammography and ultrasound was determined and compared. A total of 628 patients with 518 mammograms and 423 ultrasounds were reviewed. The final diagnoses were: 19 carcinomas, 526 gynaecomastias, 84 other benign conditions and 25 normal. There were statistically significant differences in age, bilateral involvement, clinical presentation and physical examination between patients with carcinoma and those with gynaecomastia. The diagnostic performance of physical examination was lower than that of mammography and ultrasound (p < 0.05 for specificity). Mammography was the most sensitive (94.7%) and ultrasound the most specific (95.3%) for detection of malignancy (p > 0.05). We propose an algorithm for the use of mammography and ultrasound in men. Mammography and ultrasound, with a negative predictive value close to 100%, make it possible to avoid very many unnecessary surgical procedures in men. (orig.)

  1. Segmentation of breast ultrasound images based on active contours using neutrosophic theory.

    Science.gov (United States)

    Lotfollahi, Mahsa; Gity, Masoumeh; Ye, Jing Yong; Mahlooji Far, A

    2018-04-01

    Ultrasound imaging is an effective approach for diagnosing breast cancer, but it is highly operator-dependent. Recent advances in computer-aided diagnosis have suggested that it can assist physicians in diagnosis. Definition of the region of interest before computer analysis is still needed. Since manual outlining of the tumor contour is tedious and time-consuming for a physician, developing an automatic segmentation method is important for clinical application. The present paper represents a novel method to segment breast ultrasound images. It utilizes a combination of region-based active contour and neutrosophic theory to overcome the natural properties of ultrasound images including speckle noise and tissue-related textures. First, due to inherent speckle noise and low contrast of these images, we have utilized a non-local means filter and fuzzy logic method for denoising and image enhancement, respectively. This paper presents an improved weighted region-scalable active contour to segment breast ultrasound images using a new feature derived from neutrosophic theory. This method has been applied to 36 breast ultrasound images. It generates true-positive and false-positive results, and similarity of 95%, 6%, and 90%, respectively. The purposed method indicates clear advantages over other conventional methods of active contour segmentation, i.e., region-scalable fitting energy and weighted region-scalable fitting energy.

  2. Evolution of Robot-assisted ultrasound-guided breast biopsy systems

    Directory of Open Access Journals (Sweden)

    Mustafa Z. Mahmoud

    2018-01-01

    Full Text Available Robot-assisted ultrasound-guided breast biopsy combines ultrasound (US imaging with a robotic system for medical interventions. This study was designed to provide a literature review of a robotic US-guided breast biopsy system to delineate its efficacious impact on current medical practice. In addition, the strengths and limitations of this approach were also addressed. Articles published in the English language between 2000 and 2016 were appraised in this review. A wide range of systems that bind robotics with US imaging and guided breast biopsy were examined in this article. The fundamental safety and real-time imaging capabilities of US, together with the accuracy and maneuverability of robotic devices, is clearly an effective association with unmatched capabilities. Numerous experimental systems have obvious benefits over old-fashioned techniques, and the future of robot-assisted US-guided breast biopsy will be characterized by increasing levels of automation, and they hold tremendous possibility to impact doctor achievement, patient recovery, and clinical management.

  3. Speckle noise reduction in breast ultrasound images: SMU (srad median unsharp) approch

    International Nuclear Information System (INIS)

    Njeh, I.; Sassi, O. B.; Ben Hamida, A.; Chtourou, K.

    2011-01-01

    Image denoising has become a very essential for better information extraction from the image and mainly from so noised ones, such as ultrasound images. In certain cases, for instance in ultrasound images, the noise can restrain information which is valuable for the general practitioner. Consequently medical images are very inconsistent, and it is crucial to operate case to case. This paper presents a novel algorithm SMU (Srad Median Unsharp) for noise suppression in ultrasound breast images in order to realize a computer aided diagnosis (CAD) for breast cancer.

  4. The utilization of an ultrasound-guided 8-gauge vacuum-assisted breast biopsy system as an innovative approach to accomplishing complete eradication of multiple bilateral breast fibroadenomas

    Directory of Open Access Journals (Sweden)

    Povoski Stephen P

    2007-10-01

    Full Text Available Abstract Background Ultrasound-guided vacuum-assisted breast biopsy technology is extremely useful for diagnostic biopsy of suspicious breast lesions and for attempted complete excision of appropriately selected presumed benign breast lesions. Case presentation A female patient presented with 16 breast lesions (eight within each breast, documented on ultrasound and all presumed to be fibroadenomas. Over a ten and one-half month period of time, 14 of these 16 breast lesions were removed under ultrasound guidance during a total of 11 separate 8-gauge Mammotome® excision procedures performed during seven separate sessions. Additionally, two of these 16 breast lesions were removed by open surgical excision. A histopathologic diagnosis of fibroadenoma and/or fibroadenomatous changes was confirmed at all lesion excision sites. Interval follow-up ultrasound imaging revealed no evidence of a residual lesion at the site of any of the 16 original breast lesions. Conclusion This report describes an innovative approach of utilizing ultrasound-guided 8-gauge vacuum-assisted breast biopsy technology for assisting in achieving complete eradication of multiple bilateral fibroadenomas in a patient who presented with 16 documented breast lesions. As such, this innovative approach is highly recommended in similar appropriately selected patients.

  5. Breast Cancer Diagnosis Using Ultrasound and Diffusive Light

    National Research Council Canada - National Science Library

    Zhu, Quing

    2001-01-01

    The main goal of this study is to evaluate a novel imaging system and method that combines ultrasound with near infrared diffusive light to increase the sensitivity and specificity of breast cancer detection...

  6. Value of breast MRI as supplement to mammography and sonography for high risk breast cancer patients; Wertigkeit der Mamma-MRT als Ergaenzung zu Mammographie und Sonographie bei Patientinnen mit erhoehtem Mammakarzinomrisiko

    Energy Technology Data Exchange (ETDEWEB)

    Schlossbauer, T.; Hellerhoff, K.; Reiser, M. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2008-04-15

    The aim of this study is to give an overview on early detection of breast cancer in patients with an increased risk of breast cancer. Sensitivities and diagnostic accuracies of breast MRI, mammography and ultrasound were compared. A systematic literature search of the past 3 years was performed. Studies which compared breast imaging modalities and used image-guided biopsy results as standard of reference were included. Patients included had to have had an increased lifetime risk for breast cancer (>15%). Regarding sensitivity and diagnostic accuracy, breast MRI performed best in comparison to the other modalities within this collective of patients. Sensitivities ranged from 71-100%, 0-78%, and 13-65%, for MRI, mammography, and ultrasound, respectively Breast MRI is a well established tool for screening in patients at high risk for developing breast cancer and is a valuable supplement to mammography and ultrasound within this selected cohort of patients. (orig.) [German] Ziele der Arbeit sind die inhaltliche Einfuehrung in das Thema Frueherkennung des Mammakarzinoms bei Patientinnen mit erhoehtem Risiko und eine systematische Analyse der Wertigkeit von MRT und anderen bildgebenden Verfahren in diesem Zusammenhang. Es wurde eine systematische Literaturrecherche ueber die letzten 3 Jahre durchgefuehrt. Dabei wurden Vergleichsstudien der verschiedenen bildgebenden Verfahren in der Mammadiagnostik beruecksichtigt, bei denen die bildgesteuerte Biopsie als Goldstandard angegeben wurde. Von allen bildgebenden Verfahren zeigt die Mamma-MRT bei Patientinnen mit familiaerem Risiko die hoechste Sensitivitaet und diagnostische Genauigkeit bei der Detektion des Mammakarzinoms. Fuer MRT, Mammographie und Sonographie werden Sensitivitaeten zwischen 71 und 100%, 0 und 78% sowie 13 und 65% angegeben. Die Mamma-MRT ist ein etabliertes Verfahren zum Screening von Risikopatientinnen. Uebereinstimmend wird der diagnostische Nutzen der Mamma-MRT als ergaenzendes Verfahren zu Mammographie

  7. Ultrasound -a useful complementary tool to mammography in assessment of symptomatic breast diseases

    International Nuclear Information System (INIS)

    Fatima, S.T.; Zahur, Z.; Jeilani, A.; Hussain, S.J.A.

    2015-01-01

    Breast cancer is the most common female malignancy worldwide. Pakistan has the highest incidence rate of breast cancer than any other Asian population. The purpose of the study was to evaluate the worth of sono-mammography in diagnosis of symptomatic breast diseases by comparing it with mammogram. Methods: In this cross-sectional validation study, 45 subjects with mean age of 45+-12.07 were included. Majority of the patients presented with complaint of breast lump. After complete history and clinical examination, all the patients had high resolution ultrasound of bilateral breasts and axilla followed by bilateral mammography. Histopathology was taken as gold standard in this study. The exclusion criteria were pregnancy and patients having direct clinical signs of breast malignancy. Results: Based on histopathology, out of 45 patients with breast symptoms, 12 patients had benign lesions, whereas 32 patients were diagnosed as the cases of breast cancers. Finally one patient did not have biopsy proven final diagnosis. Sensitivity and specificity of ultrasound were calculated to be 100% and 67% as compared to sensitivity and specificity of 90.6% and 91.7% for that of mammography. Conclusions: Ultrasound is a useful complementary tool to mammography in assessment of symptomatic breast diseases since it helps in characterization and localization of breast lesions seen on mammogram and it is not limited by dense breasts. Also it should be the considered as initial imaging technique for assessment of palpable breast lumps. (author)

  8. Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, K., E-mail: kathryn.taylor@addenbrookes.nhs.uk [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); O' Keeffe, S.; Britton, P.D.; Wallis, M.G. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Treece, G.M.; Housden, J. [Department of Engineering, University of Cambridge, Cambridge (United Kingdom); Parashar, D.; Bond, S. [Cambridge Cancer Trials Centre, Department of Oncology, University of Cambridge, Addenbrookes Hospital, Cambridge (United Kingdom); Cambridge Hub in Trials Methodology Research, MRC Biostatics Unit, University Forvie Site, Cambridge (United Kingdom); Sinnatamby, R. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-11-15

    Aims: To compare the performance of ultrasound elastography with conventional ultrasound in the assessment of axillary lymph nodes in suspected breast cancer and whether ultrasound elastography as an adjunct to conventional ultrasound can increase the sensitivity of conventional ultrasound used alone. Materials and methods: Fifty symptomatic women with a sonographic suspicion for breast cancer underwent ultrasound elastography of the ipsilateral axilla concurrent with conventional ultrasound being performed as part of triple assessment. Elastograms were visually scored, strain measurements calculated and node area and perimeter measurements taken. Theoretical biopsy cut points were selected. The sensitivity, specificity, positive predictive value (PPV), and negative predictive values (NPV) were calculated and receiver operating characteristic (ROC) analysis was performed and compared for elastograms and conventional ultrasound images with surgical histology as the reference standard. Results: The mean age of the women was 57 years. Twenty-nine out of 50 of the nodes were histologically negative on surgical histology and 21 were positive. The sensitivity, specificity, PPV, and NPV for conventional ultrasound were 76, 78, 70, and 81%, respectively; 90, 86, 83, and 93%, respectively, for visual ultrasound elastography; and for strain scoring, 100, 48, 58 and 100%, respectively. There was no significant difference between any of the node measurements Conclusions: Initial experience with ultrasound elastography of axillary lymph nodes, showed that it is more sensitive than conventional ultrasound in detecting abnormal nodes in the axilla in cases of suspected breast cancer. The specificity remained acceptable and ultrasound elastography used as an adjunct to conventional ultrasound has the potential to improve the performance of conventional ultrasound alone.

  9. Ultrasound Imaging Methods for Breast Cancer Detection

    NARCIS (Netherlands)

    Ozmen, N.

    2014-01-01

    The main focus of this thesis is on modeling acoustic wavefield propagation and implementing imaging algorithms for breast cancer detection using ultrasound. As a starting point, we use an integral equation formulation, which can be used to solve both the forward and inverse problems. This thesis

  10. Value of mammography and breast ultrasound in male patients with nipple discharge.

    Science.gov (United States)

    Muñoz Carrasco, Rafaela; Álvarez Benito, Marina; Rivin del Campo, Eleonor

    2013-03-01

    To assess the contribution of mammography and ultrasound in men with nipple discharge. All men with nipple discharge who underwent mammography and/or ultrasound between 1993 and 2011 in our hospital were retrospectively evaluated. Radiological findings were classified according to BI-RADS lexicon. The final diagnosis was made based on histopathological results or clinical-radiological follow-up. The diagnostic performance of physical examination, mammography and ultrasound was calculated and compared. 26 men with 21 mammograms and 19 ultrasounds were reviewed. The final diagnoses were: 6 carcinomas (23.1%), 10 gynaecomastias, 2 pseudogynaecomastias and 8 normal breast tissues. Mammograms and ultrasounds performed on all five patients with infiltrating carcinoma showed a mass (categories 4 and 5). In all these patients except one, a breast mass was also noted and the physical examination was positive or suspected malignancy. In the patient with carcinoma in situ, the only conspicuous clinical sign was bloody nipple discharge and the mammography showed calcifications (category 4) that were not visible on ultrasound. Radiological findings of all patients without malignancy were classified as categories 1 and 2. The diagnostic performance of physical examination was lower than mammography and ultrasound (P>0.05). Mammography was more sensitive than ultrasound (100% vs. 83.3%). Both techniques showed the same specificity (100%). Men with nipple discharge have a high incidence of breast carcinoma. Nipple discharge may be the only clinical sign of carcinoma in situ. Mammography and ultrasound are useful in the evaluation of men with nipple discharge, diagnosing carcinoma in initial stages, avoiding unnecessary biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. 3-D Ultrasound Vascularity Assessment for Breast Cancer Diagnosis

    National Research Council Canada - National Science Library

    Carson, Paul

    1997-01-01

    This project is to improve the diagnosis and management of patients with breast cancer through development and evaluation of 3D ultrasound imaging and quantification techniques emphasizing vascularity...

  12. Ultrasound Guided Needle Aspiration versus Surgical Drainage in the management of breast abscesses: a Ugandan experience

    Directory of Open Access Journals (Sweden)

    Chandika Alphonce B

    2012-01-01

    Full Text Available Abstract Background Despite breast abscess becoming less common in developed countries, it has remained one of the leading causes of morbidity in women in developing countries. A randomized controlled trial was conducted at Mulago hospital complex in Kampala Uganda to establish whether ultrasound guided needle aspiration is a feasible alternative treatment option for breast abscesses. Results A total of 65 females with breast abscess were analyzed, of these 33 patients were randomized into the ultrasound guided needle aspiration and 32 patients in the Incision and drainage arm. The mean age was 23.12, most of them were lactating (66.2%, primipararous (44.6% with peripheral abscesses (73.8% located in the upper lateral quadrant (56%.The mean breast size was 3.49 cm. The two groups were comparably in demographic characteristic and breast abscess size. Survival analysis showed no difference in breast abscess healing rate between the two groups (Log rank 0.24 df 1 and P = 0.63. Incision and drainage was found to be more costly than ultrasound guided aspiration (cost effective ratio of 2.85. Conclusion Ultrasound guided needle aspiration is therefore a feasible and cost effective treatment option for both lactating and non lactating breast abscesses with a diameter up to 5 cm by ultrasound in an immune competent patient

  13. Correlation of contrast-enhanced ultrasound parameters with oncogene expression and cell proliferation activity in breast cancer

    Institute of Scientific and Technical Information of China (English)

    Ce Zhang

    2017-01-01

    Objective: To study the correlation of contrast-enhanced ultrasound parameters with oncogene expression and cell proliferation activity in breast cancer. Methods: Breast cancer lesions and benign breast lesions surgically removed in Zigong Third People's Hospital between May 2014 and February 2017 were selected, contrast-enhanced ultrasound was done before operation to draw the time-intensity curve and calculate the area under the curve (AUC), and the expression of proliferation molecules and tumor suppressor genes were detected after operation. Results:The contrast-enhanced ultrasound parameter AUC of the breast cancer lesion was greatly higher than that of the benign breast lesion; ECT2, ZKSCAN3, USP39 and EphA2 mRNA expression in breast cancer lesions were obviously higher than those in benign breast lesions whereas HPK1, TCEAL17, CCN5, ATG2B and ATG4D mRNA expression were greatly lower than those in benign breast lesions; ECT2, ZKSCAN3, USP39 and EphA2 mRNA expression in breast cancer lesions with high AUC were greatly higher than those in breast cancer lesions with low AUC whereas HPK1, TCEAL17, CCN5, ATG2B and ATG4D mRNA expression were greatly lower than those in breast cancer lesions with low AUC. Conclusion: The contrast-enhanced ultrasound parameter AUC of breast cancer lesion significantly increases and is closely related to the higher expression of pro-proliferation molecules and the lower expression of tumor suppressor genes.

  14. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    OpenAIRE

    Dang, J; Lecoq, P; Tavernier, S; Lasaygues, P; Mensah, S; Zhang, D C; Auffray, E; Frisch, B; Varela, J; Wan, M X; Felix, N

    2011-01-01

    International audience; Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allo...

  15. Comb-push ultrasound shear elastography of breast masses: initial results show promise.

    Science.gov (United States)

    Denis, Max; Mehrmohammadi, Mohammad; Song, Pengfei; Meixner, Duane D; Fazzio, Robert T; Pruthi, Sandhya; Whaley, Dana H; Chen, Shigao; Fatemi, Mostafa; Alizad, Azra

    2015-01-01

    To evaluate the performance of Comb-push Ultrasound Shear Elastography (CUSE) for classification of breast masses. CUSE is an ultrasound-based quantitative two-dimensional shear wave elasticity imaging technique, which utilizes multiple laterally distributed acoustic radiation force (ARF) beams to simultaneously excite the tissue and induce shear waves. Female patients who were categorized as having suspicious breast masses underwent CUSE evaluations prior to biopsy. An elasticity estimate within the breast mass was obtained from the CUSE shear wave speed map. Elasticity estimates of various types of benign and malignant masses were compared with biopsy results. Fifty-four female patients with suspicious breast masses from our ongoing study are presented. Our cohort included 31 malignant and 23 benign breast masses. Our results indicate that the mean shear wave speed was significantly higher in malignant masses (6 ± 1.58 m/s) in comparison to benign masses (3.65 ± 1.36 m/s). Therefore, the stiffness of the mass quantified by the Young's modulus is significantly higher in malignant masses. According to the receiver operating characteristic curve (ROC), the optimal cut-off value of 83 kPa yields 87.10% sensitivity, 82.61% specificity, and 0.88 for the area under the curve (AUC). CUSE has the potential for clinical utility as a quantitative diagnostic imaging tool adjunct to B-mode ultrasound for differentiation of malignant and benign breast masses.

  16. Microbiological properties of poultry breast meat treated with high-intensity ultrasound.

    Science.gov (United States)

    Piñon, M I; Alarcon-Rojo, A D; Renteria, A L; Carrillo-Lopez, L M

    2018-01-03

    Lactic acid, psychrophilic, and mesophilic bacteria, Escherichia coli, Salmonella spp. and Staphylococcus aureus were enumerated on chicken breasts after treatment with different high intensity ultrasound (frequency 40 kHz, intensity 9.6 W/cm -2 ) application times (0, 30, and 50 min) and packaging atmospheres (aerobic and vacuum) after a 7-day storage. The experiment was performed in commercial 7-week-old chicken breasts. Counts were performed prior to and immediately after ultrasonication, and on the 7th day of chill-storage. After sonication and storage, mesophiles, psychrophiles, LAB and S. aureus increased statistically. Psychrophiles decreased significantly under anaerobic packaging. There were no differences among ultrasonication times in terms of mesophiles, psychrophiles, LAB, E. coli and Salmonella spp. S. aureus numbers had a significant reduction after 50 min sonication. Under these experimental conditions, high-intensity ultrasound for 50 min is a control method of S. aureus and the anaerobic packaging reduces numbers of psychrophiles in chicken breast. The effect of ultrasound is only significant after the storage time. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. An optimized ultrasound detector for photoacoustic breast tomography

    NARCIS (Netherlands)

    Xia, Wenfeng; Piras, Daniele; van Hespen, Johan C. G.; van Veldhoven, Spiridon; Prins, Christian; van Leeuwen, Ton G.; Steenbergen, Wiendelt; Manohar, Srirang

    2013-01-01

    Photoacoustic imaging has proven to be able to detect vascularization-driven optical absorption contrast associated with tumors. In order to detect breast tumors located a few centimeter deep in tissue, a sensitive ultrasound detector is of crucial importance for photoacoustic mammography. Further,

  18. Automated Breast Ultrasound Lesions Detection using Convolutional Neural Networks.

    Science.gov (United States)

    Yap, Moi Hoon; Pons, Gerard; Marti, Joan; Ganau, Sergi; Sentis, Melcior; Zwiggelaar, Reyer; Davison, Adrian K; Marti, Robert

    2017-08-07

    Breast lesion detection using ultrasound imaging is considered an important step of Computer-Aided Diagnosis systems. Over the past decade, researchers have demonstrated the possibilities to automate the initial lesion detection. However, the lack of a common dataset impedes research when comparing the performance of such algorithms. This paper proposes the use of deep learning approaches for breast ultrasound lesion detection and investigates three different methods: a Patch-based LeNet, a U-Net, and a transfer learning approach with a pretrained FCN-AlexNet. Their performance is compared against four state-of-the-art lesion detection algorithms (i.e. Radial Gradient Index, Multifractal Filtering, Rule-based Region Ranking and Deformable Part Models). In addition, this paper compares and contrasts two conventional ultrasound image datasets acquired from two different ultrasound systems. Dataset A comprises 306 (60 malignant and 246 benign) images and Dataset B comprises 163 (53 malignant and 110 benign) images. To overcome the lack of public datasets in this domain, Dataset B will be made available for research purposes. The results demonstrate an overall improvement by the deep learning approaches when assessed on both datasets in terms of True Positive Fraction, False Positives per image, and F-measure.

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  20. Practice guideline for the performance of breast ultrasound elastography.

    Science.gov (United States)

    Lee, Su Hyun; Chang, Jung Min; Cho, Nariya; Koo, Hye Ryoung; Yi, Ann; Kim, Seung Ja; Youk, Ji Hyun; Son, Eun Ju; Choi, Seon Hyeong; Kook, Shin Ho; Chung, Jin; Cha, Eun Suk; Park, Jeong Seon; Jung, Hae Kyoung; Ko, Kyung Hee; Choi, Hye Young; Ryu, Eun Bi; Moon, Woo Kyung

    2014-01-01

    Ultrasound (US) elastography is a valuable imaging technique for tissue characterization. Two main types of elastography, strain and shear-wave, are commonly used to image breast tissue. The use of elastography is expected to increase, particularly with the increased use of US for breast screening. Recently, the US elastographic features of breast masses have been incorporated into the 2nd edition of the Breast Imaging Reporting and Data System (BI-RADS) US lexicon as associated findings. This review suggests practical guidelines for breast US elastography in consensus with the Korean Breast Elastography Study Group, which was formed in August 2013 to perform a multicenter prospective study on the use of elastography for US breast screening. This article is focused on the role of elastography in combination with B-mode US for the evaluation of breast masses. Practical tips for adequate data acquisition and the interpretation of elastography results are also presented.

  1. Practice guideline for the performance of breast ultrasound elastography

    International Nuclear Information System (INIS)

    Lee, Su Hyun; Chang, Jung Min; Cho, Nariya

    2014-01-01

    Ultrasound (US) elastography is a valuable imaging technique for tissue characterization. Two main types of elastography, strain and shear-wave, are commonly used to image breast tissue. The use of elastography is expected to increase, particularly with the increased use of US for breast screening. Recently, the US elastographic features of breast masses have been incorporated into the 2nd edition of the Breast Imaging Reporting and Data System (BI-RADS) US lexicon as associated findings. This review suggests practical guidelines for breast US elastography in consensus with the Korean Breast Elastography Study Group, which was formed in August 2013 to perform a multicenter prospective study on the use of elastography for US breast screening. This article is focused on the role of elastography in combination with B-mode US for the evaluation of breast masses. Practical tips for adequate data acquisition and the interpretation of elastography results are also presented.

  2. Practice guideline for the performance of breast ultrasound elastography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Su Hyun; Chang, Jung Min; Cho, Nariya [Dept. of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); and others

    2014-03-15

    Ultrasound (US) elastography is a valuable imaging technique for tissue characterization. Two main types of elastography, strain and shear-wave, are commonly used to image breast tissue. The use of elastography is expected to increase, particularly with the increased use of US for breast screening. Recently, the US elastographic features of breast masses have been incorporated into the 2nd edition of the Breast Imaging Reporting and Data System (BI-RADS) US lexicon as associated findings. This review suggests practical guidelines for breast US elastography in consensus with the Korean Breast Elastography Study Group, which was formed in August 2013 to perform a multicenter prospective study on the use of elastography for US breast screening. This article is focused on the role of elastography in combination with B-mode US for the evaluation of breast masses. Practical tips for adequate data acquisition and the interpretation of elastography results are also presented.

  3. Comb-push ultrasound shear elastography of breast masses: initial results show promise.

    Directory of Open Access Journals (Sweden)

    Max Denis

    Full Text Available To evaluate the performance of Comb-push Ultrasound Shear Elastography (CUSE for classification of breast masses.CUSE is an ultrasound-based quantitative two-dimensional shear wave elasticity imaging technique, which utilizes multiple laterally distributed acoustic radiation force (ARF beams to simultaneously excite the tissue and induce shear waves. Female patients who were categorized as having suspicious breast masses underwent CUSE evaluations prior to biopsy. An elasticity estimate within the breast mass was obtained from the CUSE shear wave speed map. Elasticity estimates of various types of benign and malignant masses were compared with biopsy results.Fifty-four female patients with suspicious breast masses from our ongoing study are presented. Our cohort included 31 malignant and 23 benign breast masses. Our results indicate that the mean shear wave speed was significantly higher in malignant masses (6 ± 1.58 m/s in comparison to benign masses (3.65 ± 1.36 m/s. Therefore, the stiffness of the mass quantified by the Young's modulus is significantly higher in malignant masses. According to the receiver operating characteristic curve (ROC, the optimal cut-off value of 83 kPa yields 87.10% sensitivity, 82.61% specificity, and 0.88 for the area under the curve (AUC.CUSE has the potential for clinical utility as a quantitative diagnostic imaging tool adjunct to B-mode ultrasound for differentiation of malignant and benign breast masses.

  4. Categorization and evaluation of usefulness of breast lesions with using ultrasound BI-RADS (breast imaging reporting and data system)

    International Nuclear Information System (INIS)

    Kim, Youn Jeong; Choi, Hye Young; Moon, Byung In; Lee, Shi Nae

    2006-01-01

    The aim of our study was to determine the positive predictive value (PPV) and to evaluate the usefulness on ultrasound BI-RADS, as compared with the histologic results of breast lesions that were categorized and classified by the ultrasound BI-RADS lexicon. Between January and December 2004, the ultrasound features of 471 breast lesions in 368 patients were analyzed and categorized with using ultrasound BI-RADS. All of the lesions were compared with the histological results. We categorized category 2 and 3 lesions as benign lesions, and category 4 and 5 lesions as malignant lesions. We then calculated the sensitivity, specificity, positive, predictive value, negative predictive value and accuracy. The breast lesions were histologically diagnosed as 298 cases of category 2, 21 cases of category 3, 108 cases of category 4 and 44 cases of category 5. The categorical malignancy rate was 1% (3/298) in category 2 lesions, 4.7% (1/21) in category 3 lesions, 8.3% (9/108) in category 4 lesions and 90.9% (40/44) in category 5 lesions. Within category 4, the malignancy rate for category 4a lesions was 5.4% (5/92), the malignancy rate for category 4b lesions was 1.3% (1/8) and the malignancy rate for category 4c lesions was 50% (4/8). The sensitivity, specificity, positive predictive value and negative predictive value were 90.6%, 75.1%, 31.6% and 98.4%, respectively. The statistically valid ultrasound features that were correlated with malignancy were an ill defined margin, a microlobulated mass, an irregular mass, inhomogenic echogenicity, an echogenic halo and an older patient age. Ultrasound BI-RADS was useful in differentiating benign from malignant breast lesions

  5. Building a virtual simulation platform for quasistatic breast ultrasound elastography using open source software: A preliminary investigation.

    Science.gov (United States)

    Wang, Yu; Helminen, Emily; Jiang, Jingfeng

    2015-09-01

    Quasistatic ultrasound elastography (QUE) is being used to augment in vivo characterization of breast lesions. Results from early clinical trials indicated that there was a lack of confidence in image interpretation. Such confidence can only be gained through rigorous imaging tests using complex, heterogeneous but known media. The objective of this study is to build a virtual breast QUE simulation platform in the public domain that can be used not only for innovative QUE research but also for rigorous imaging tests. The main thrust of this work is to streamline biomedical ultrasound simulations by leveraging existing open source software packages including Field II (ultrasound simulator), VTK (geometrical visualization and processing), FEBio [finite element (FE) analysis], and Tetgen (mesh generator). However, integration of these open source packages is nontrivial and requires interdisciplinary knowledge. In the first step, a virtual breast model containing complex anatomical geometries was created through a novel combination of image-based landmark structures and randomly distributed (small) structures. Image-based landmark structures were based on data from the NIH Visible Human Project. Subsequently, an unstructured FE-mesh was created by Tetgen. In the second step, randomly positioned point scatterers were placed within the meshed breast model through an octree-based algorithm to make a virtual breast ultrasound phantom. In the third step, an ultrasound simulator (Field II) was used to interrogate the virtual breast phantom to obtain simulated ultrasound echo data. Of note, tissue deformation generated using a FE-simulator (FEBio) was the basis of deforming the original virtual breast phantom in order to obtain the postdeformation breast phantom for subsequent ultrasound simulations. Using the procedures described above, a full cycle of QUE simulations involving complex and highly heterogeneous virtual breast phantoms can be accomplished for the first time

  6. Practice guideline for the performance of breast ultrasound elastography

    Directory of Open Access Journals (Sweden)

    Su Hyun Lee

    2014-01-01

    Full Text Available

    Ultrasound (US elastography is a valuable imaging technique for tissue characterization. Two main types of elastography, strain and shear-wave, are commonly used to image breast tissue. The use of elastography is expected to increase, particularly with the increased use of US for breast screening. Recently, the US elastographic features of breast masses have been incorporated into the 2nd edition of the Breast Imaging Reporting and Data System (BI-RADS US lexicon as associated findings. This review suggests practical guidelines for breast US elastography in consensus with the Korean Breast Elastography Study Group, which was formed in August 2013 to perform a multicenter prospective study on the use of elastography for US breast screening. This article is focused on the role of elastography in combination with B-mode US for the evaluation of breast masses. Practical tips for adequate data acquisition and the interpretation of elastography results are also presented.

  7. Quantitative ultrasound characterization of locally advanced breast cancer by estimation of its scatterer properties

    Energy Technology Data Exchange (ETDEWEB)

    Tadayyon, Hadi [Physical Sciences, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Biophysics, Faculty of Medicine, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Sadeghi-Naini, Ali; Czarnota, Gregory, E-mail: Gregory.Czarnota@sunnybrook.ca [Physical Sciences, Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Medical Biophysics, Faculty of Medicine, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Department of Radiation Oncology, Odette Cancer Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada); Department of Radiation Oncology, Faculty of Medicine, University of Toronto, Toronto, Ontario M5T 1P5 (Canada); Wirtzfeld, Lauren [Department of Physics, Ryerson University, Toronto, Ontario M5B 2K3 (Canada); Wright, Frances C. [Division of Surgical Oncology, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5 (Canada)

    2014-01-15

    Purpose: Tumor grading is an important part of breast cancer diagnosis and currently requires biopsy as its standard. Here, the authors investigate quantitative ultrasound parameters in locally advanced breast cancers that can potentially separate tumors from normal breast tissue and differentiate tumor grades. Methods: Ultrasound images and radiofrequency data from 42 locally advanced breast cancer patients were acquired and analyzed. Parameters related to the linear regression of the power spectrum—midband fit, slope, and 0-MHz-intercept—were determined from breast tumors and normal breast tissues. Mean scatterer spacing was estimated from the spectral autocorrelation, and the effective scatterer diameter and effective acoustic concentration were estimated from the Gaussian form factor. Parametric maps of each quantitative ultrasound parameter were constructed from the gated radiofrequency segments in tumor and normal tissue regions of interest. In addition to the mean values of the parametric maps, higher order statistical features, computed from gray-level co-occurrence matrices were also determined and used for characterization. Finally, linear and quadratic discriminant analyses were performed using combinations of quantitative ultrasound parameters to classify breast tissues. Results: Quantitative ultrasound parameters were found to be statistically different between tumor and normal tissue (p < 0.05). The combination of effective acoustic concentration and mean scatterer spacing could separate tumor from normal tissue with 82% accuracy, while the addition of effective scatterer diameter to the combination did not provide significant improvement (83% accuracy). Furthermore, the two advanced parameters, including effective scatterer diameter and mean scatterer spacing, were found to be statistically differentiating among grade I, II, and III tumors (p = 0.014 for scatterer spacing, p = 0.035 for effective scatterer diameter). The separation of the tumor

  8. Quantitative ultrasound characterization of locally advanced breast cancer by estimation of its scatterer properties

    International Nuclear Information System (INIS)

    Tadayyon, Hadi; Sadeghi-Naini, Ali; Czarnota, Gregory; Wirtzfeld, Lauren; Wright, Frances C.

    2014-01-01

    Purpose: Tumor grading is an important part of breast cancer diagnosis and currently requires biopsy as its standard. Here, the authors investigate quantitative ultrasound parameters in locally advanced breast cancers that can potentially separate tumors from normal breast tissue and differentiate tumor grades. Methods: Ultrasound images and radiofrequency data from 42 locally advanced breast cancer patients were acquired and analyzed. Parameters related to the linear regression of the power spectrum—midband fit, slope, and 0-MHz-intercept—were determined from breast tumors and normal breast tissues. Mean scatterer spacing was estimated from the spectral autocorrelation, and the effective scatterer diameter and effective acoustic concentration were estimated from the Gaussian form factor. Parametric maps of each quantitative ultrasound parameter were constructed from the gated radiofrequency segments in tumor and normal tissue regions of interest. In addition to the mean values of the parametric maps, higher order statistical features, computed from gray-level co-occurrence matrices were also determined and used for characterization. Finally, linear and quadratic discriminant analyses were performed using combinations of quantitative ultrasound parameters to classify breast tissues. Results: Quantitative ultrasound parameters were found to be statistically different between tumor and normal tissue (p < 0.05). The combination of effective acoustic concentration and mean scatterer spacing could separate tumor from normal tissue with 82% accuracy, while the addition of effective scatterer diameter to the combination did not provide significant improvement (83% accuracy). Furthermore, the two advanced parameters, including effective scatterer diameter and mean scatterer spacing, were found to be statistically differentiating among grade I, II, and III tumors (p = 0.014 for scatterer spacing, p = 0.035 for effective scatterer diameter). The separation of the tumor

  9. Routine use of standard breast MRI compared to axillary ultrasound for differentiating between no, limited and advanced axillary nodal disease in newly diagnosed breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Nijnatten, T.J.A. van, E-mail: Thiemovn@gmail.com [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); GROW – School for Oncology and Developmental Biology, Maastricht University Medical Center+, Maastricht (Netherlands); Ploumen, E.H. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); Schipper, RJ. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); GROW – School for Oncology and Developmental Biology, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Catharina Hospital, Eindhoven (Netherlands); Goorts, B. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); GROW – School for Oncology and Developmental Biology, Maastricht University Medical Center+, Maastricht (Netherlands); Andriessen, E.H. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); Vanwetswinkel, S.; Schavemaker, M. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Nelemans, P. [Department of Epidemiology, Maastricht University Medical Center+, Maastricht (Netherlands); Vries, B. de [Department of Pathology, Zuyderland Hospital, Heerlen (Netherlands); and others

    2016-12-15

    Objectives: To compare standard breast MRI to dedicated axillary ultrasound (with or without tissue sampling) for differentiating between no, limited and advanced axillary nodal disease in breast cancer patients. Methods: All patients who underwent breast MRI and dedicated axillary ultrasound between 2009 and 2014 were eligible. Exclusion criteria were recurrent disease, neoadjuvant systemic therapy and not receiving completion axillary lymph node dissection after positive sentinel lymph node biopsy (SLNB). Two radiologists independently reassessed all MRI exams. Axillary ultrasound findings were retrospectively collected. Probability of advanced axillary nodal disease (pN2-3) given clinically node negative (cN0) or limited (cN1) findings was calculated, with corresponding negative predictive value (NPV) to exclude pN2-3 and positive predictive value (PPV) to identify axillary nodal disease. Histopathology served as gold standard. Results: A total of 377 cases resulted in 81.4% no, 14.4% limited and 4.2% advanced axillary nodal disease at final histopathology. Probability of pN2-3 given cN0 for breast MRI and axillary ultrasound was 0.7–0.9% versus 1.5% and probability of pN2-3 given cN1 was 11.6–15.4% versus 29.0%. When cN1 on breast MRI was observed, PPV to identify positive axillary nodal disease was 50.7% and 59.0%. Conclusions: Evaluation of axillary nodal status on standard breast MRI is comparable to dedicated axillary ultrasound in breast cancer patients. In patients who underwent preoperative standard breast MRI, axillary ultrasound is only required in case of suspicious nodal findings on MRI.

  10. Phytotherapy and Nutritional Supplements on Breast Cancer

    Directory of Open Access Journals (Sweden)

    C. M. Lopes

    2017-01-01

    Full Text Available Breast cancer is the most frequent type of nonskin malignancy among women worldwide. In general, conventional cancer treatment options (i.e., surgery, radiotherapy, chemotherapy, biological therapy, and hormone therapy are not completely effective. Recurrence and other pathologic situations are still an issue in breast cancer patients due to side effects, toxicity of drugs in normal cells, and aggressive behaviour of the tumours. From this point of view, breast cancer therapy and adjuvant methods represent a promising and challenging field for researchers. In the last few years, the use of some types of complementary medicines by women with a history of breast cancer has significantly increased such as phytotherapeutic products and nutritional supplements. Despite this, the use of such approaches in oncologic processes may be problematic and patient’s health risks can arise such as interference with the efficacy of standard cancer treatment. The present review gives an overview of the most usual phytotherapeutic products and nutritional supplements with application in breast cancer patients as adjuvant approach. Regardless of the contradictory results of scientific evidence, we demonstrated the need to perform additional investigation, mainly well-designed clinical trials in order to establish correlations and allow for further validated outcomes concerning the efficacy, safety, and clinical evidence-based recommendation of these products.

  11. Ultrasound-guided Breast Biopsy in the Resource-limited Setting: An Initial Experience in Rural Uganda

    Directory of Open Access Journals (Sweden)

    Christopher R. Stark

    2017-06-01

    Full Text Available Purpose: To describe the methodology and initial experience behind creation of an ultrasoundguided percutaneous breast core biopsy program in rural Uganda. Methods and Materials: Imaging the World Africa (ITWA is the registered non-governmental organization division of Imaging the World (ITW, a not-for-profit organization whose primary aim is the integration of affordable high-quality ultrasound into rural health centers. In 2013, ITWA began the pilot phase of an IRB-approved breast care protocol at a rural health center in Uganda. As part of the protocol’s diagnostic arm, an ultrasound-guided percutaneous breast core biopsy training curriculum was implemented in tandem with creation of regionally supplied biopsy kits. Results: A surgeon at a rural regional referral hospital was successfully trained and certified to perform ultrasound-guided percutaneous breast core biopsies. Affordable and safe biopsy kits were created using locally available medical supplies with the cost of each kit totaling $10.62 USD. Conclusion: Successful implementation of an ultrasound-guided percutaneous breast core biopsy program in the resource-limited setting is possible and can be made sustainable through incorporation of local health care personnel and regionally supplied biopsy materials. Our hope is that ITWA’s initial experience in rural Uganda can serve as a model for similar programs in the future.

  12. Ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage

    International Nuclear Information System (INIS)

    Naper, M.A.; Shaikh, M.S.; Dholia, K.R.

    2017-01-01

    To evaluate the outcome and assess the success rate of ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage. Methodology: A prospective descriptive study was carried out at Department of Surgery, Chandka Medical College Hospital, Larkana, Pakistan, from January 2015 to December 2015. A total of 111 patients of breast abscess who underwent ultrasound guided aspiration without anesthesias with oral antibiotic cover were studied. Females with breast abscess within seven days, and the abscess size was <3cm were included in the study. Males, antibioma and inflammatory carcinoma were excluded from the study. Outcome of success or failure was observed within two weeks and recorded. Results: Out of 111 patients, 68.46% were lactating and 31.53% were non-lactating women, with ages ranging from 18 to 60 years (mean 36.5 years). The successful rate with complete resolution after ultrasound guided aspiration was observed in 94.5%. 80.82% responded after single aspiration, 12.38% after two times aspiration, and 6.66% after multiple aspirations, while 5.4% of patients required incision and drainage. Conclusion: Ultrasound guided aspiration of breast abscess is an effective treatment option with a diameter of <3cm, which can be recommended as a routine outpatient procedure. (author)

  13. Ultrasound-guided, vacuum-assisted biopsy in evaluation of breast lesions

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Dyczek, S.; Skotnicki, P.; Stelmach, A.; Herman, K.

    2008-01-01

    Aim. Evaluation of the efficacy of ultrasound-guided vacuum-assisted biopsy for the verification of breast lesions. Introduction. Ultrasound breast examination is a noninvasive method of breast imaging. It is adjunct to mammography and physical examination and, in women under 30 years of age, pregnant and lactating, it is the basic examination used for the detection and diagnosing of breast diseases. It allows also to obtain cells or tissue samples with such minimally invasive techniques as fine-needle biopsy, core needle biopsy or vacuum-assisted biopsy. Material and methods. The study group consisted of 138 women, aged from 20 to 76 years, who underwent ultrasound guided vacuum-assisted biopsy between March and December 2006. Because double lesions were diagnosed in 6 patients, this resulted in 144 performed procedures. Each patient underwent ultrasound examination, performed with a 10-12 MHz transducer. Biopsies were guided by a 12 MHz transducer and performed with the Mammotome System using an 11G or an 8G needle, depending upon the size and site of the lesion. Obtained data were compared using the Chi-square test; p values of less than 0.05 were considered indicative of a significant difference. Results. The average size of the biopted lesions was estimated as 11±3,8 mm (range: 4-30 mm). However, lesions described by radiologists as apparently suspicious were not qualified for the vacuum-assisted biopsy, in the tested material 4 lesions appeared to be carcinomas (3 were invasive breast carcinomas and 1 was ductal carcinoma in situ). When compared with other changes, these lesions were most frequently equivocal (3 vs 1 determined as benign, p=0.014). There was no statistically significant difference in echogenicity (3 hypoechoic vs 1 with mixed echogenicity) nor in the shape (1 oval change, 2 lobulated and 1 irregular). Pathological examination revealed 86 cases of fibroadenoma within the tested material. Those lesions were mostly benign (77 vs 9 equivocal

  14. Impact of Simulation-Based Training on Radiology Trainee Education in Ultrasound-Guided Breast Biopsies.

    Science.gov (United States)

    Roark, Ashley A; Ebuoma, Lilian O; Ortiz-Perez, Tamara; Sepulveda, Karla A; Severs, Frederick J; Wang, Tao; Benveniste, Ana Paula; Sedgwick, Emily L

    2017-12-05

    The aim of this study is to determine the impact of a simulation-based ultrasound-guided (USG) breast biopsy training session on radiology trainee procedural knowledge, comfort levels, and overall procedural confidence and anxiety. Twenty-one diagnostic radiology residents from a single academic institution were recruited to participate in an USG breast biopsy training session. The residents filled out a questionnaire before and after the training session. Ten multiple-choice questions tested general knowledge in diagnostic breast ultrasound and USG breast biopsy concepts. Subjective comfort levels with ultrasound machine and biopsy device functionality, patient positioning, proper biopsy technique, image documentation, needle safety and overall procedural confidence and anxiety levels were reported on a 5-point Likert scale before and after training. Participants demonstrated significant improvement in number of correctly answered general knowledge questions after training (P simulation-based USG breast biopsy training session may improve radiology trainee procedural knowledge, comfort levels, and overall procedural confidence. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  15. Logistic discriminant analysis of breast cancer using ultrasound measurement

    International Nuclear Information System (INIS)

    Abdolmaleki, P.; Mokhtari Dizaji, M.; Vahead, M.R.; Gity, M.

    2004-01-01

    Background: Logistic discriminant method was applied to differentiate malignant from benign in a group of patients with proved breast lesions of the basis of ultrasonic parameters. Materials and methods: Our database include 273 patients' ultrasonographic pictures consisting of 14 quantitative variables. The measured variables were ultrasound propagation velocity, acoustic impedance and attenuation coefficient at 10 MHz in breast lesions at 20, 25, 30 and 35 d ig c temperature, physical density and age. This database was randomly divided into the estimation of 201 and validation of 72 samples. The estimation samples were used to build the logistic discriminant model, and validation samples were used to validate the performance. Finally important criteria such as sensitivity, specificity, accuracy and area under the receiver operating characteristic curve were evaluated. Results: Our results showed that the logistic discriminant method was able to classify correctly 67 out of 72 cases presented in the validation sample. The results indicate a remarkable diagnostic accuracy of 93%. Conclusion: A logistic discriminator approach is capable of predicting the probability of malignancy of breast cancer. Features from ultrasonic measurement on ultrasound imaging is used in this approach

  16. Quantitative analysis of breast echotexture patterns in automated breast ultrasound images

    International Nuclear Information System (INIS)

    Chang, Ruey-Feng; Hou, Yu-Ling; Lo, Chung-Ming; Huang, Chiun-Sheng; Chen, Jeon-Hor; Kim, Won Hwa; Chang, Jung Min; Bae, Min Sun; Moon, Woo Kyung

    2015-01-01

    Purpose: Breast tissue composition is considered to be associated with breast cancer risk. This study aimed to develop a computer-aided classification (CAC) system to automatically classify echotexture patterns as heterogeneous or homogeneous using automated breast ultrasound (ABUS) images. Methods: A CAC system was proposed that can recognize breast echotexture patterns in ABUS images. For each case, the echotexture pattern was assessed by two expert radiologists and classified as heterogeneous or homogeneous. After neutrosophic image transformation and fuzzy c-mean clusterings, the lower and upper boundaries of the fibroglandular tissues were defined. Then, the number of hypoechoic regions and histogram features were extracted from the fibroglandular tissues, and the support vector machine model with the leave-one-out cross-validation method was utilized as the classifier. The authors’ database included a total of 208 ABUS images of the breasts of 104 females. Results: The accuracies of the proposed system for the classification of heterogeneous and homogeneous echotexture patterns were 93.48% (43/46) and 92.59% (150/162), respectively, with an overall Az (area under the receiver operating characteristic curve) of 0.9786. The agreement between the radiologists and the proposed system was almost perfect, with a kappa value of 0.814. Conclusions: The use of ABUS and the proposed method can provide quantitative information on the echotexture patterns of the breast and can be used to evaluate whether breast echotexture patterns are associated with breast cancer risk in the future

  17. Quantitative analysis of breast echotexture patterns in automated breast ultrasound images

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Ruey-Feng [Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei 10617, Taiwan and Department of Computer Science and Information Engineering, National Taiwan University, Taipei 10617, Taiwan (China); Hou, Yu-Ling [Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei 10617, Taiwan (China); Lo, Chung-Ming [Department of Computer Science and Information Engineering, National Taiwan University, Taipei 10617, Taiwan (China); Huang, Chiun-Sheng [Department of Surgery, National Taiwan University Hospital, Taipei 10617, Taiwan (China); Chen, Jeon-Hor [Department of Radiology, E-Da Hospital and I-Shou University, Kaohsiung 82445, Taiwan and Tu and Yuen Center for Functional Onco-Imaging and Department of Radiological Science, University of California, Irvine, California 92697 (United States); Kim, Won Hwa; Chang, Jung Min; Bae, Min Sun; Moon, Woo Kyung, E-mail: moonwk@snu.ac.kr [Department of Radiology, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of)

    2015-08-15

    Purpose: Breast tissue composition is considered to be associated with breast cancer risk. This study aimed to develop a computer-aided classification (CAC) system to automatically classify echotexture patterns as heterogeneous or homogeneous using automated breast ultrasound (ABUS) images. Methods: A CAC system was proposed that can recognize breast echotexture patterns in ABUS images. For each case, the echotexture pattern was assessed by two expert radiologists and classified as heterogeneous or homogeneous. After neutrosophic image transformation and fuzzy c-mean clusterings, the lower and upper boundaries of the fibroglandular tissues were defined. Then, the number of hypoechoic regions and histogram features were extracted from the fibroglandular tissues, and the support vector machine model with the leave-one-out cross-validation method was utilized as the classifier. The authors’ database included a total of 208 ABUS images of the breasts of 104 females. Results: The accuracies of the proposed system for the classification of heterogeneous and homogeneous echotexture patterns were 93.48% (43/46) and 92.59% (150/162), respectively, with an overall Az (area under the receiver operating characteristic curve) of 0.9786. The agreement between the radiologists and the proposed system was almost perfect, with a kappa value of 0.814. Conclusions: The use of ABUS and the proposed method can provide quantitative information on the echotexture patterns of the breast and can be used to evaluate whether breast echotexture patterns are associated with breast cancer risk in the future.

  18. Breast Microcalcification Detection Using Super-Resolution Ultrasound Image Reconstruction

    Science.gov (United States)

    2010-09-01

    tissues. These differences in mechanical properties result in ultrasound scattering. Because the sizes of breast microcalcifications are smaller than...2006). [4] Karssemeijer, N., Bluekens, A. M., Beijerinck, D., Deurenberg, J. J., Beekman, M., Visser, R., van Engen , R., Bartels- Kortland, A., and

  19. Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts: Interim Report of a Prospective Comparative Trial.

    Science.gov (United States)

    Tagliafico, Alberto S; Calabrese, Massimo; Mariscotti, Giovanna; Durando, Manuela; Tosto, Simona; Monetti, Francesco; Airaldi, Sonia; Bignotti, Bianca; Nori, Jacopo; Bagni, Antonella; Signori, Alessio; Sormani, Maria Pia; Houssami, Nehmat

    2016-03-09

    Debate on adjunct screening in women with dense breasts has followed legislation requiring that women be informed about their mammographic density and related adjunct imaging. Ultrasound or tomosynthesis can detect breast cancer (BC) in mammography-negative dense breasts, but these modalities have not been directly compared in prospective trials. We conducted a trial of adjunct screening to compare, within the same participants, incremental BC detection by tomosynthesis and ultrasound in mammography-negative dense breasts. Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts is a prospective multicenter study recruiting asymptomatic women with mammography-negative screens and dense breasts. Eligible women had tomosynthesis and physician-performed ultrasound with independent interpretation of adjunct imaging. Outcome measures included cancer detection rate (CDR), number of false-positive (FP) recalls, and incremental CDR for each modality; these were compared using McNemar's test for paired binary data in a preplanned interim analysis. Among 3,231 mammography-negative screening participants (median age, 51 years; interquartile range, 44 to 78 years) with dense breasts, 24 additional BCs were detected (23 invasive): 13 tomosynthesis-detected BCs (incremental CDR, 4.0 per 1,000 screens; 95% CI, 1.8 to 6.2) versus 23 ultrasound-detected BCs (incremental CDR, 7.1 per 1,000 screens; 95% CI, 4.2 to 10.0), P = .006. Incremental FP recall occurred in 107 participants (3.33%; 95% CI, 2.72% to 3.96%). FP recall (any testing) did not differ between tomosynthesis (FP = 53) and ultrasound (FP = 65), P = .26; FP recall (biopsy) also did not differ between tomosynthesis (FP = 22) and ultrasound (FP = 24), P = .86. The Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts' interim analysis shows that ultrasound has better incremental BC detection than tomosynthesis in mammography

  20. Ultrasound as a secondary screening tool in mammographically dense breasts

    International Nuclear Information System (INIS)

    Griggs, Kylie

    2006-01-01

    It is well known that breast screening is a part of our society and is designed to reduce the mortality and morbidity from breast cancer. Mammography is the imaging modality of choice in a breast-screening environment. Both the detection rate of mammography in a screening environment and the sensitivity of mammography in symptomatic women are known to be greater than that of ultrasound. However, after a review of literature both of these are said to increase when the two imaging modalities are combined. This paper will present that mammography has limitation

  1. Breast ultrasound in the management of gynecomastia in Peutz-Jeghers syndrome in monozygotic twins: two case reports.

    Science.gov (United States)

    Di Grezia, Graziella; Romano, Tiziana; De Francesco, Francesco; Somma, Francesco; Rea, Gaetano; Grassi, Roberto; Gatta, Gianluca

    2014-12-18

    Peutz-Jeghers syndrome is an autosomal dominant disease with incomplete penetrance and variable expression caused by germline mutation of serine threonine kinase 11/liver kinase B1; it is characterized by hamartomatous polyps in the gastrointestinal tract, mucocutaneous melanin pigmentation, and increased predisposition to neoplasms. In Peutz-Jeghers syndrome, bilateral Sertoli cell testicular tumors cause endocrine manifestations including gynecomastia and feminization. This study aimed to assess the role of breast ultrasound in the evaluation of the effectiveness of an innovative surgical approach. This report presents a pair of European 9-year-old identical male twins with Peutz-Jeghers syndrome, bilateral prepubertal gynecomastia, and testicular multifocal calcifications. Both twins were treated with anastrozole for 2 years. After finishing treatment, both underwent subcutaneous mastectomy performed by the "modified" Webster technique. Breast examination and ultrasound were performed before and after the pharmacological and surgical treatment. A breast ultrasound scan before surgery showed bilateral gynecomastia in both patients. No solid nodular or cystic formations were present on either side. After pharmacological therapy and surgical glandular removal, a breast examination showed a significant reduction in breast volume; 1 year after surgery, a breast ultrasound scan of both patients showed a total absence of glandular parenchyma, with muscle planes well represented. Breast examination and ultrasound have proved to be a valid approach in the assessment of the treatment of prepubertal gynecomastia because they allow the efficacy of the pharmacological and surgical treatment to be evaluated in a multidisciplinary approach to one of the most frequent endocrine manifestations of Peutz-Jeghers syndrome.

  2. Polyvinyl chloride plastisol breast phantoms for ultrasound imaging.

    Science.gov (United States)

    de Carvalho, Isabela Miller; De Matheo, Lucas Lobianco; Costa Júnior, José Francisco Silva; Borba, Cecília de Melo; von Krüger, Marco Antonio; Infantosi, Antonio Fernando Catelli; Pereira, Wagner Coelho de Albuquerque

    2016-08-01

    Ultrasonic phantoms are objects that mimic some features of biological tissues, allowing the study of their interactions with ultrasound (US). In the diagnostic-imaging field, breast phantoms are an important tool for testing performance and optimizing US systems, as well as for training medical professionals. This paper describes the design and manufacture of breast lesions by using polyvinyl chloride plastisol (PVCP) as the base material. Among the materials available for this study, PVCP was shown to be stable, durable, and easy to handle. Furthermore, it is a nontoxic, nonpolluting, and low-cost material. The breast's glandular tissue (image background) was simulated by adding graphite powder with a concentration of 1% to the base material. Mixing PVCP and graphite powder in differing concentrations allows one to simulate lesions with different echogenicity patterns (anechoic, hypoechoic, and hyperechoic). From this mixture, phantom materials were obtained with speed of sound varying from 1379.3 to 1397.9ms(-1) and an attenuation coefficient having values between 0.29 and 0.94dBcm(-1) for a frequency of 1MHz at 24°C. A single layer of carnauba wax was added to the lesion surface in order to evaluate its applicability for imaging. The images of the phantoms were acquired using commercial ultrasound equipment; a specialist rated the images, elaborating diagnoses representative of both benign and malignant lesions. The results indicated that it was possible to easily create a phantom by using low-cost materials, readily available in the market and stable at room temperature, as the basis of ultrasonic phantoms that reproduce the image characteristics of fatty breast tissue and typical lesions of the breast. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. THE VALUE OF ULTRASOUND MAMMOGRAPHY IN PALPABLE BREAST MASSES

    NARCIS (Netherlands)

    VANOORD, JC; VANDERVLIET, AM; THYN, CJP; MAK, B; HOOGEBOOM, GJ

    Between January 1987 and May 1988 a prospective study was carried out on 232 women with a palpable breast mass. They underwent physical examination, x-ray mammography and ultrasound mammography. The results of each study were interpreted independently by separate observers, and consensus was

  4. Computerized Analysis of MR and Ultrasound Images of Breast Lesions

    National Research Council Canada - National Science Library

    Giger, Maryellen Lissak

    2000-01-01

    ...) images of breast lesions to aid radiologists in their workup of suspect lesions. We currently have retrospectively collected over 400 ultrasound cases of mass lesions, all that had gone on to either biopsy or cyst aspiration...

  5. 3.0 Tesla breast magnetic resonance imaging in patients with nipple discharge when mammography and ultrasound fail.

    Science.gov (United States)

    Lubina, Nóra; Schedelbeck, Ulla; Roth, Anne; Weng, Andreas Max; Geissinger, Eva; Hönig, Arnd; Hahn, Dietbert; Bley, Thorsten Alexander

    2015-05-01

    To compare 3.0 Tesla breast magnetic resonance imaging (MRI) with galactography for detection of benign and malignant causes of nipple discharge in patients with negative mammography and ultrasound. We prospectively evaluated 56 breasts of 50 consecutive patients with nipple discharge who had inconspicuous mammography and ultrasound, using 3.0 Tesla breast MRI with a dedicated 16-channel breast coil, and then compared the results with galactography. Histopathological diagnoses and follow-ups were used as reference standard. Lesion size estimated on MRI was compared with the size at histopathology. Sensitivity and specificity of MRI vs. galactography for detecting pathologic findings were 95.7 % vs. 85.7 % and 69.7 % vs. 33.3 %, respectively. For the supposed concrete pathology based on MRI findings, the specificity was 67.6 % and the sensitivity 77.3 % (PPV 60.7 %, NPV 82.1 %). Eight malignant lesions were detected (14.8 %). The estimated size at breast MRI showed excellent correlation with the size at histopathology (Pearson's correlation coefficient 0.95, p 3.0 Tesla is an accurate imaging test and can replace galactography in the workup of nipple discharge in patients with inconspicuous mammography and ultrasound. • Breast MRI is an excellent diagnostic tool for patients with nipple discharge. • MRI of the breast reveals malignant lesions despite inconspicuous mammography and ultrasound. • MRI of the breast has greater sensitivity and specificity than galactography. • Excellent correlation of lesion size measured at MRI and histopathology was found.

  6. Quantitative shear wave ultrasound elastography: initial experience in solid breast masses.

    Science.gov (United States)

    Evans, Andrew; Whelehan, Patsy; Thomson, Kim; McLean, Denis; Brauer, Katrin; Purdie, Colin; Jordan, Lee; Baker, Lee; Thompson, Alastair

    2010-01-01

    Shear wave elastography is a new method of obtaining quantitative tissue elasticity data during breast ultrasound examinations. The aims of this study were (1) to determine the reproducibility of shear wave elastography (2) to correlate the elasticity values of a series of solid breast masses with histological findings and (3) to compare shear wave elastography with greyscale ultrasound for benign/malignant classification. Using the Aixplorer® ultrasound system (SuperSonic Imagine, Aix en Provence, France), 53 solid breast lesions were identified in 52 consecutive patients. Two orthogonal elastography images were obtained of each lesion. Observers noted the mean elasticity values in regions of interest (ROI) placed over the stiffest areas on the two elastography images and a mean value was calculated for each lesion. A sub-set of 15 patients had two elastography images obtained by an additional operator. Reproducibility of observations was assessed between (1) two observers analysing the same pair of images and (2) findings from two pairs of images of the same lesion taken by two different operators. All lesions were subjected to percutaneous biopsy. Elastography measurements were correlated with histology results. After preliminary experience with 10 patients a mean elasticity cut off value of 50 kilopascals (kPa) was selected for benign/malignant differentiation. Greyscale images were classified according to the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS). BI-RADS categories 1-3 were taken as benign while BI-RADS categories 4 and 5 were classified as malignant. Twenty-three benign lesions and 30 cancers were diagnosed on histology. Measurement of mean elasticity yielded an intraclass correlation coefficient of 0.99 for two observers assessing the same pairs of elastography images. Analysis of images taken by two independent operators gave an intraclass correlation coefficient of 0.80. Shear wave elastography versus

  7. Contrast ultrasound-guided photothermal therapy using gold nanoshelled microcapsules in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shumin [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Ordos Center Hospital, Ordos, Inner Mongolia 017000 (China); Dai, Zhifei [Department of Biomedical Engineering, College of Engineering, Peking University, Beijing 100871 (China); Ke, Hengte [Nanomedicine and Biosensor Laboratory, School of Life Science and Technology, Harbin Institute of Technology, Harbin 150001 (China); Qu, Enze [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Qi, Xiaoxu; Zhang, Kuo [Department of Laboratory Animal Science, Peking University Health Science Center, Beijing 100019 (China); Wang, Jinrui, E-mail: jinrui_wang@sina.com [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China)

    2014-01-15

    Objectives: The purpose of this study was to test whether dual functional gold nano-shelled microcapsules (GNS-MCs) can be used as an ultrasound imaging enhancer and as an optical absorber for photothermal therapy (PTT) in a rodent model of breast cancer. Methods: GNS-MCs were fabricated with an inner air and outer gold nanoshell spherical structure. Photothermal cytotoxicity of GNS-MCs was tested with BT474 cancer cells in vitro and non-obese diabetes-SCID (NOD/SCID) mice with breast cancer. GNS-MCs were injected into the tumor under ultrasound guidance and treated with near-infrared (NIR) laser irradiation. The photothermal ablative effectiveness of GNS-MCs was evaluated by measuring the surface and internal temperature of the tumor as well as the size of the tumor using histological confirmation. Results: NIR laser irradiation resulted in significant tumor cell death in GNS-MCs-treated BT474 cells in vitro. GNS-MCs were able to serve as an ultrasound enhancer to guide the intratumoral injection of GNS-MCs and ensure their uniform distribution. In vivo studies revealed that NIR laser irradiation increased the intratumoral temperature to nearly 70 °C for 8 min in GNS-MCs-treated mice. Tumor volumes decreased gradually and tumors were completely ablated in 6 out of 7 mice treated with GNS-MCs and laser irradiation by 17 days after treatment. Conclusion: This study demonstrates that ultrasound-guided PTT with theranostic GNS-MCs is a promising technique for in situ treatment of breast cancer.

  8. Image-guided focused ultrasound ablation of breast cancer: current status, challenges, and future directions

    NARCIS (Netherlands)

    Schmitz, A.C.; Gianfelice, D.; Daniel, B.L.; Mali, W.P.T.M.; Bosch, M.A.A.J. van den

    2008-01-01

    Image-guided focussed ultrasound (FUS) ablation is a noninvasive procedure that has been used for treatment of benign or malignant breast tumours. Image-guidance during ablation is achieved either by using real-time ultrasound (US) or magnetic resonance imaging (MRI). The past decade phase I

  9. Indications for axillary ultrasound use in breast cancer patients.

    Science.gov (United States)

    Joh, Jennifer E; Han, Gang; Kiluk, John V; Laronga, Christine; Khakpour, Nazanin; Lee, M Catherine

    2012-12-01

    Axillary ultrasound has been adopted for preoperative planning in breast cancer. Our objective was to determine features predictive of abnormal AUS and/or positive axillary node needle biopsy (NBx). Single-institution database of breast cancer patients identified patients with preoperative AUS. Patient characteristics and outcomes were correlated with AUS and NBx. Significant features were identified using univariable and multivariable analysis and correlative statistics. Three hundred thirteen breast cancers were evaluated. Abnormal AUS was demonstrated in 250 cases (80%). Node needle biopsy was performed in 247 cases (79%). Sensitivity and specificity was 93% and 48% for AUS and 86% and 100% for NBx, respectively. Palpable axillary adenopathy was significant in logistic regression model (P AUS and NBx (P AUS. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. The inter-observer variability of breast density scoring between mammography technologists and breast radiologists and its effect on the rate of adjuvant ultrasound.

    Science.gov (United States)

    Mazor, Roei D; Savir, Avital; Gheorghiu, David; Weinstein, Yuliana; Abadi-Korek, Ifat; Shabshin, Nogah

    2016-05-01

    This study assesses the inter-observer variability of mammographic breast density scoring (BDS) between technologists and radiologists and evaluates the effect of technologist patient referral on the load of adjuvant ultrasounds. In this IRB approved study, a retrospective analysis of 503 prospectively acquired, random mammograms was performed between January and March 2014. Each mammogram was evaluated for BDS independently and blindly by both the performing technologist and the interpreting radiologist. Statistical calculation of the Spearman correlation coefficient and weighted kappa were obtained to evaluate the inter-observer variability between technologists and radiologists and to examine whether it relates to the technologist's seniority or women's age. The effect on the load of adjuvant ultrasounds was evaluated. 10 mammography technologists and 7 breast radiologists participated in this study. BDS agreement levels between technologists and radiologists were in the fair to moderate range (kappa values: 0.3-0.45, Spearman coefficient values: 0.59-0.65). The technologists markedly over-graded the density compared to the radiologists in all the subsets evaluated. Comparison between low and high-density groups demonstrated a similar trend of over-grading by technologists, who graded 51% of the women as having dense breasts (scores 3-4) compared to 27% of the women graded as such by the radiologists. This trend of over grading breast density by technologists was unrelated to the women's age or to the technologists' seniority. Mammography technologists over-grade breast density. Technologists' referral to an adjuvant ultrasound leads to redundant ultrasound studies, unnecessary breast biopsies, costs and increased patient anxiety. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    CERN Document Server

    Dang, J; Tavernier, S; Lasaygues, P; Mensah, S; Zhang, D C; Auffray, E; Frisch, B; Varela, J; Wan, M X; Felix, N

    2011-01-01

    Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allows labeling the different tissues in the phantom with different concentrations of FDG. The phantom was imaged with a whole-body PET/CT and with the Supersonic Imagine Aixplorer system. This system allows both B-mode US and shear wave elastographic imaging. US elastography is a new imaging method for displaying the tissue elasticity distribution. It was shown to be useful in breast imaging. We also tested the phantom with static elastography. A 6D magnetic positioning system allows fusing the images obtained with the two modalities. ClearPEM-Soni...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  13. Targeted Ultrasound of an Indeterminate Breast Lesion on Mammography: When Does It Influence Management?

    Science.gov (United States)

    Sohail, Saba; Masroor, Imrana; Afzal, Shaista

    2015-08-01

    To determine the change over mammographic diagnosis, BI-RADS category and management following targeted ultrasound of an indeterminate lesion seen on mammography and associated factors, if any. Descriptive, analytical study. Radiology Department, The Aga Khan University Hospital and Clifton Medical Services, Karachi, from April 2010 to May 2011. Patients referred for targeted breast ultrasound following X-ray mammography were selected regardless of age. Targeted Ultrasound (TUS) was defined as a limited ultrasound of a specific lesion or breast part as indicated by the referring source. Comparison was made between the post mammography and post TUS lesion characterization, diagnosis and BI-RADS category (0-5) which was taken as a measure of management change. Those were evaluated to determine significance of age, marital status, parity, breast parenchymal pattern ( dense, fatty, heterogeneous), referring source for the TUS (radiology resident, radiologist or surgeon), lesion characteristics (density, echogenecity, shape, location, margins, size, depth-to-width ratio, enhancement or shadowing), presenting symptoms or signs and reason for TUS. Ap-value of 0.05 or less was taken as significant. There were a total of 342 patients with mean age of 49.7 ±13.5 years. It assigned a definite category in 232 patients with an indefinite category (0) on mammography requiring further investigation. It decreased the suspicion for malignancy in 180 (77.58%) by assigning a low BI-RADS category and increased the suspicion in 52 (22.41%). The factors significantly associated with this changes included clinical indication being diagnostic (p management of an indeterminate breast lesion in a high number of patients, particularly when there was a lump as indication for imaging in the presence of risk factors in a patient with otherwise heterogeneously dense breast parenchyma.

  14. Phytoestrogens in menopausal supplements induce ER-dependent cell proliferation and overcome breast cancer treatment in an in vitro breast cancer model

    International Nuclear Information System (INIS)

    Duursen, Majorie B.M. van; Smeets, Evelien E.J.W.; Rijk, Jeroen C.W.; Nijmeijer, Sandra M.; Berg, Martin van den

    2013-01-01

    Breast cancer treatment by the aromatase inhibitor Letrozole (LET) or Selective Estrogen Receptor Modulator Tamoxifen (TAM) can result in the onset of menopausal symptoms. Women often try to relieve these symptoms by taking menopausal supplements containing high levels of phytoestrogens. However, little is known about the potential interaction between these supplements and breast cancer treatment, especially aromatase inhibitors. In this study, interaction of phytoestrogens with the estrogen receptor alpha and TAM action was determined in an ER-reporter gene assay (BG1Luc4E2 cells) and human breast epithelial tumor cells (MCF-7). Potential interactions with aromatase activity and LET were determined in human adrenocorticocarcinoma H295R cells. We also used the previously described H295R/MCF-7 co-culture model to study interactions with steroidogenesis and tumor cell proliferation. In this model, genistein (GEN), 8-prenylnaringenin (8PN) and four commercially available menopausal supplements all induced ER-dependent tumor cell proliferation, which could not be prevented by physiologically relevant LET and 4OH-TAM concentrations. Differences in relative effect potencies between the H295R/MCF-7 co-culture model and ER-activation in BG1Luc4E2 cells, were due to the effects of the phytoestrogens on steroidogenesis. All tested supplements and GEN induced aromatase activity, while 8PN was a strong aromatase inhibitor. Steroidogenic profiles upon GEN and 8PN exposure indicated a strong inhibitory effect on steroidogenesis in H295R cells and H295R/MCF-7 co-cultures. Based on our in vitro data we suggest that menopausal supplement intake during breast cancer treatment should better be avoided, at least until more certainty regarding the safety of supplemental use in breast cancer patients can be provided. - Highlights: • Supplements containing phytoestrogens are commonly used by women with breast cancer. • Phytoestrogens alter steroidogenesis in a co-culture breast

  15. Phytoestrogens in menopausal supplements induce ER-dependent cell proliferation and overcome breast cancer treatment in an in vitro breast cancer model

    Energy Technology Data Exchange (ETDEWEB)

    Duursen, Majorie B.M. van, E-mail: M.vanDuursen@uu.nl [Endocrine Toxicology, Institute for Risk Assessment Sciences, Utrecht University, Yalelaan 104, PO Box 80177, 3508 TD, Utrecht (Netherlands); Smeets, Evelien E.J.W. [Endocrine Toxicology, Institute for Risk Assessment Sciences, Utrecht University, Yalelaan 104, PO Box 80177, 3508 TD, Utrecht (Netherlands); Rijk, Jeroen C.W. [RIKILT - Institute for Food Safety, Wageningen UR, P.O. Box 230, 6700 AE, Wageningen (Netherlands); Nijmeijer, Sandra M.; Berg, Martin van den [Endocrine Toxicology, Institute for Risk Assessment Sciences, Utrecht University, Yalelaan 104, PO Box 80177, 3508 TD, Utrecht (Netherlands)

    2013-06-01

    Breast cancer treatment by the aromatase inhibitor Letrozole (LET) or Selective Estrogen Receptor Modulator Tamoxifen (TAM) can result in the onset of menopausal symptoms. Women often try to relieve these symptoms by taking menopausal supplements containing high levels of phytoestrogens. However, little is known about the potential interaction between these supplements and breast cancer treatment, especially aromatase inhibitors. In this study, interaction of phytoestrogens with the estrogen receptor alpha and TAM action was determined in an ER-reporter gene assay (BG1Luc4E2 cells) and human breast epithelial tumor cells (MCF-7). Potential interactions with aromatase activity and LET were determined in human adrenocorticocarcinoma H295R cells. We also used the previously described H295R/MCF-7 co-culture model to study interactions with steroidogenesis and tumor cell proliferation. In this model, genistein (GEN), 8-prenylnaringenin (8PN) and four commercially available menopausal supplements all induced ER-dependent tumor cell proliferation, which could not be prevented by physiologically relevant LET and 4OH-TAM concentrations. Differences in relative effect potencies between the H295R/MCF-7 co-culture model and ER-activation in BG1Luc4E2 cells, were due to the effects of the phytoestrogens on steroidogenesis. All tested supplements and GEN induced aromatase activity, while 8PN was a strong aromatase inhibitor. Steroidogenic profiles upon GEN and 8PN exposure indicated a strong inhibitory effect on steroidogenesis in H295R cells and H295R/MCF-7 co-cultures. Based on our in vitro data we suggest that menopausal supplement intake during breast cancer treatment should better be avoided, at least until more certainty regarding the safety of supplemental use in breast cancer patients can be provided. - Highlights: • Supplements containing phytoestrogens are commonly used by women with breast cancer. • Phytoestrogens alter steroidogenesis in a co-culture breast

  16. Increasing the diagnosis of multifocal primary breast cancer by the use of bilateral whole-breast ultrasound

    International Nuclear Information System (INIS)

    Wilkinson, L.S.; Given-Wilson, R.; Hall, T.; Potts, H.; Sharma, A.K.; Smith, E.

    2005-01-01

    AIM: The aim of this study was to evaluate the contribution of bilateral whole-breast ultrasound (BBUS) to the diagnosis and management of women with newly diagnosed breast cancer. METHODS: Over a period of 6 months, 102 women presenting with breast cancer underwent BBUS. Data were collected on clinical findings, radiology, histology and surgical outcome. These women were compared with a control group of 124 women presenting over a similar 6-month period 1 year previously, who had undergone targeted breast ultrasound. RESULTS: Multicentric/multifocal tumours were demonstrated in 35 (34%) of the 102 participants and in 18 (15%) of the 124 controls, a statistically significant difference (Fisher's exact test, p=0.001). Multiple tumours were diagnosed preoperatively in 18% of the study population compared with 8% of the controls, and BBUS identified invasive multifocal/multicentric tumours in significantly more women in the study population (11 versus 1 control) (Fisher's exact test, p=0.019). Contralateral cancer was diagnosed in 4 women in the study population and none in the control population (Fisher's exact test, p=0.040). Surgical review showed that the surgical management changed significantly in 8% (95% confidence interval 4 to 14%) of cases in the study population following BBUS. The increase in the number of women undergoing benign biopsies in the study population (10 versus 5 controls) was not statistically significant (Fisher's exact test, p=0.11). CONCLUSION: BBUS increased the preoperative diagnosis of multiple tumours in women presenting with primary breast cancer, resulting in a management change in 8% of cases

  17. The Role of Doppler Ultrasound in Assessing the Therapeutic Response in Advanced Breast Cancer

    Directory of Open Access Journals (Sweden)

    Jamal Eyvazi-Ziaei

    2018-01-01

    Full Text Available Background and Objectives: Breast cancer is one of the most common cancers in Iran, which neo-adjuvant chemotherapy used to treat in advanced types to reduce tumor burden. The aim of this study was to evaluate the ultrasound scales of patients with advanced disease, using two common treatment methods include TACs (Taxotere, Adriamycin, and Cyclophosphamide and AC (Adriamycin, Cyclophosphamide. Material and Methods: Clinical examination and Doppler ultrasound were performed before and after treatment. Before and after the treatment, the size of the primary tumor and tumor vascularization, and the ultrasound Resistivity Index (RI, Pulsality Index (PI, Peak Systolic Velocity (PSV and the condition of the anterior lymph nodes, and the effect of two different therapies were investigated in response to treatment. The SPSS statistical software 17.0 was used to evaluate the relationship between the variables with 95% confidence interval, and P≤ 0.05. Results: The mean age of the patients was 48.90 (±10.58 SD years. From these, 8 were postmenopausal and 9 were menopausal, and in 3 cases the situation was unknown. There was significant difference between the PSV levels of the main breast mass, pre and post chemotherapy (P=0.004. Changes in other indexes of breast mass and axillary mass were not statistical significant. Conclusion: Color Doppler ultrasonography seems to be a promising alternative as an independent and complementary tool, to assess the response to treatment of breast masses to primary medical treatment in advanced breast cancers.

  18. Breast-density assessment with hand-held ultrasound: A novel biomarker to assess breast cancer risk and to tailor screening?

    Science.gov (United States)

    Sanabria, Sergio J; Goksel, Orcun; Martini, Katharina; Forte, Serafino; Frauenfelder, Thomas; Kubik-Huch, Rahel A; Rominger, Marga B

    2018-03-19

    To assess feasibility and diagnostic accuracy of a novel hand-held ultrasound (US) method for breast density assessment that measures the speed of sound (SoS), in comparison to the ACR mammographic (MG) categories. ACR-MG density (a=fatty to d=extremely dense) and SoS-US were assessed in the retromamillary, inner and outer segments of 106 women by two radiographers. A conventional US system was used for SoS-US. A reflector served as timing reference for US signals transmitted through the breasts. Four blinded readers assessed average SoS (m/s), ΔSoS (segment-variation SoS; m/s) and the ACR-MG density. The highest SoS and ΔSoS values of the three segments were used for MG-ACR whole breast comparison. SoS-US breasts were examined in densities a-d were 1,421 m/s (SD 14), 1,432 m/s (SD 17), 1,448 m/s (SD 20) and 1,500 m/s (SD 31), with significant differences between all groups (pdensity was evident (r s =0.622, p=density without discomfort, readers evaluated measurements with high inter-reader agreement, and SoS-US correlated significantly with ACR-MG breast-density categories. • The novel speed-of-sound ultrasound correlated significantly with mammographic ACR breast density categories. • Radiographers measured breast density without women discomfort or radiation. • SoS-US can be implemented on a standard US machine. • SoS-US shows potential for a quantifiable, cost-effective assessment of breast density.

  19. [Contrastive study on conventional ultrasound, compression elastography and acoustic radiation force impulse imaging in the differential diagnosis of benign and malignant breast tumors].

    Science.gov (United States)

    Zhang, Lu; Zhou, Ping; Deng, Jin; Tian, Shuangming; Qian, Ying; Wu, Xiaomin; Ma, Shuhua; Li, Jiale

    2014-12-01

    To evaluate the diagnostic performance of conventional ultrasound, compression elastography (CE) and acoustic radiation force impulse imaging (ARFI) in differential diagnosis of benign and malignant breast tumors. A total of 98 patients with liver lesions were included in the study. The images of conventional ultrasound, CE and the values of virtual touch tissue quantification (VTQ) of breast lesions were obtained. The diagnostic performance of conventional ultrasound, CE and ARFI were assessed by using pathology as the gold standard, and then evaluate the diagnosis efficiency of these three approaches in differential diagnosing benign and malignant breast tumors. The specificity, sensitivity and accuracy in the diagnosis of malignant breast tumors for conventional ultrasound were 80.0%, 81.1% and 81.7%, respectively, whereas for CE elastic score were 85.7%, 86.7% and 86.3%, respectively. With a cutoff value of 3.71 for the SR, the sensitivity, specificity, accuracy in diagnosis of malignant breast tumors were 97.1%, 83.3% and 88.4%, respectively. With a cutoff value of 3.78 m/s for VTQ, the sensitivity, specificity, accuracy in diagnosis of malignant breast tumors were 94.3%, 91.7% and 92.6%, respectively. The difference in diagnosis efficiency among ARFI, CE and conventional ultrasound in differential diagnosis of benign and malignant breast tumors was significant (Pbenign and malignant breast tumors. But the diagnosis efficiency of ARFI is superior to CE and conventional ultrasound. The three approaches can help each other in differential diagnosis of benign and malignant breast tumors.

  20. Real-Time MRI Navigated Ultrasound for Preoperative Tumor Evaluation in Breast Cancer Patients: Technique and Clinical Implementation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ah Young; Seo, Bo Kyoung [Department of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan 15355 (Korea, Republic of)

    2016-11-01

    Real-time magnetic resonance imaging (MRI) navigated ultrasound is an image fusion technique to display the results of both MRI and ultrasonography on the same monitor. This system is a promising technique to improve lesion detection and analysis, to maximize advantages of each imaging modality, and to compensate the disadvantages of both MRI and ultrasound. In evaluating breast cancer stage preoperatively, MRI and ultrasound are the most representative imaging modalities. However, sometimes difficulties arise in interpreting and correlating the radiological features between these two different modalities. This pictorial essay demonstrates the technical principles of the real-time MRI navigated ultrasound, and clinical implementation of the system in preoperative evaluation of tumor extent, multiplicity, and nodal status in breast cancer patients.

  1. Real-time MRI navigated ultrasound for preoperative tumor evaluation in breast cancer patients: Technique and clinical implementation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ah Young; Seo, Bo Kyoung [Dept. of Radiology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan (Korea, Republic of)

    2016-09-15

    Real-time magnetic resonance imaging (MRI) navigated ultrasound is an image fusion technique to display the results of both MRI and ultrasonography on the same monitor. This system is a promising technique to improve lesion detection and analysis, to maximize advantages of each imaging modality, and to compensate the disadvantages of both MRI and ultrasound. In evaluating breast cancer stage preoperatively, MRI and ultrasound are the most representative imaging modalities. However, sometimes difficulties arise in interpreting and correlating the radiological features between these two different modalities. This pictorial essay demonstrates the technical principles of the real-time MRI navigated ultrasound, and clinical implementation of the system in preoperative evaluation of tumor extent, multiplicity, and nodal status in breast cancer patients.

  2. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    Science.gov (United States)

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p cancer diagnosis of $3978 ($3964-$3991) (p cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  3. 3.0 Tesla breast magnetic resonance imaging in patients with nipple discharge when mammography and ultrasound fail

    Energy Technology Data Exchange (ETDEWEB)

    Lubina, Nora; Schedelbeck, Ulla; Weng, Andreas Max; Hahn, Dietbert; Bley, Thorsten Alexander [University of Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); Roth, Anne [Centre of Radiology Wuerzburg, Wuerzburg (Germany); Geissinger, Eva [University of Wuerzburg, Institute of Pathology, Wuerzburg (Germany); Hoenig, Arnd [Catholic Clinical Centre Mainz, Department of Obstetrics and Gynecology, Mainz (Germany)

    2015-05-01

    To compare 3.0 Tesla breast magnetic resonance imaging (MRI) with galactography for detection of benign and malignant causes of nipple discharge in patients with negative mammography and ultrasound. We prospectively evaluated 56 breasts of 50 consecutive patients with nipple discharge who had inconspicuous mammography and ultrasound, using 3.0 Tesla breast MRI with a dedicated 16-channel breast coil, and then compared the results with galactography. Histopathological diagnoses and follow-ups were used as reference standard. Lesion size estimated on MRI was compared with the size at histopathology. Sensitivity and specificity of MRI vs. galactography for detecting pathologic findings were 95.7 % vs. 85.7 % and 69.7 % vs. 33.3 %, respectively. For the supposed concrete pathology based on MRI findings, the specificity was 67.6 % and the sensitivity 77.3 % (PPV 60.7 %, NPV 82.1 %). Eight malignant lesions were detected (14.8 %). The estimated size at breast MRI showed excellent correlation with the size at histopathology (Pearson's correlation coefficient 0.95, p < 0.0001). MRI of the breast at 3.0 Tesla is an accurate imaging test and can replace galactography in the workup of nipple discharge in patients with inconspicuous mammography and ultrasound. (orig.)

  4. Breast cancer screening controversies: who, when, why, and how?

    Science.gov (United States)

    Chetlen, Alison; Mack, Julie; Chan, Tiffany

    2016-01-01

    Mammographic screening is effective in reducing mortality from breast cancer. The issue is not whether mammography is effective, but whether the false positive rate and false negative rates can be reduced. This review will discuss controversies including the reduction in breast cancer mortality, overdiagnosis, the ideal screening candidate, and the optimal imaging modality for breast cancer screening. The article will compare and contrast screening mammography, tomosynthesis, whole-breast screening ultrasound, magnetic resonance imaging, and molecular breast imaging. Though supplemental imaging modalities are being utilized to improve breast cancer diagnosis, mammography still remains the gold standard for breast cancer screening. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Breast Ultrasound Examination with Video Monitor System: A Satisfaction Survey among Patients

    International Nuclear Information System (INIS)

    Ryu, Jung Kyu; Kim, Hyun Cheol; Yang, Dal Mo

    2010-01-01

    The purpose of this study is to assess the patients satisfaction with a newly established video-monitor system and the associated basic items for performing breast ultrasound exams by conducting a survey among the patients. 349 patients were invited to take the survey and they had undergone breast ultrasound examination once during the 3 months after the monitor system has been introduced. The questionnaire was composed of 8 questions, 4 of which were about the basic items such as age, gender and the reason of their taking the breast ultrasound exam, their preference for the gender of the examiner and the desired length of time for the examination. The other 4 question were about their satisfaction with the video monitor. The patients were divided into two groups according to the purposes of taking the exams, which were screening or diagnostic purposes. The results were compared between these 2 groups. The satisfaction with the video monitor system was assessed by using a scoring system that ranged from 1 to 5. For the total patients, the screening group was composed of 124 patients and the diagnostic group was composed of 225. The reasons why the patients wanted to take the examinations in the diagnostic group varied. The questionnaire about the preference of the gender of the examiner showed that 81.5% in the screening group and 79.1% in the diagnostic group preferred a woman doctor. The required, suitable time for the breast ultrasound examination was 5 to 10 minutes or 10 to 15 minutes for about 70% of the patients. The mean satisfaction score for the video monitor system was as high as 3.95 point. The portion of patients in each group who answered over 3 points for their satisfaction with the monitor system was 88.7% and 94.2%, respectively. Our study showed that patients preferred 5-15 minutes for the length of the examination time and a female examiner. We also confirmed high patient satisfaction with the video monitor system

  6. Breast Ultrasound Examination with Video Monitor System: A Satisfaction Survey among Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jung Kyu; Kim, Hyun Cheol; Yang, Dal Mo [East-West Neo Medical Center, Kyung-Hee University, Seoul (Korea, Republic of)

    2010-03-15

    The purpose of this study is to assess the patients satisfaction with a newly established video-monitor system and the associated basic items for performing breast ultrasound exams by conducting a survey among the patients. 349 patients were invited to take the survey and they had undergone breast ultrasound examination once during the 3 months after the monitor system has been introduced. The questionnaire was composed of 8 questions, 4 of which were about the basic items such as age, gender and the reason of their taking the breast ultrasound exam, their preference for the gender of the examiner and the desired length of time for the examination. The other 4 question were about their satisfaction with the video monitor. The patients were divided into two groups according to the purposes of taking the exams, which were screening or diagnostic purposes. The results were compared between these 2 groups. The satisfaction with the video monitor system was assessed by using a scoring system that ranged from 1 to 5. For the total patients, the screening group was composed of 124 patients and the diagnostic group was composed of 225. The reasons why the patients wanted to take the examinations in the diagnostic group varied. The questionnaire about the preference of the gender of the examiner showed that 81.5% in the screening group and 79.1% in the diagnostic group preferred a woman doctor. The required, suitable time for the breast ultrasound examination was 5 to 10 minutes or 10 to 15 minutes for about 70% of the patients. The mean satisfaction score for the video monitor system was as high as 3.95 point. The portion of patients in each group who answered over 3 points for their satisfaction with the monitor system was 88.7% and 94.2%, respectively. Our study showed that patients preferred 5-15 minutes for the length of the examination time and a female examiner. We also confirmed high patient satisfaction with the video monitor system

  7. Breast-Lesion Characterization using Textural Features of Quantitative Ultrasound Parametric Maps.

    Science.gov (United States)

    Sadeghi-Naini, Ali; Suraweera, Harini; Tran, William Tyler; Hadizad, Farnoosh; Bruni, Giancarlo; Rastegar, Rashin Fallah; Curpen, Belinda; Czarnota, Gregory J

    2017-10-20

    This study evaluated, for the first time, the efficacy of quantitative ultrasound (QUS) spectral parametric maps in conjunction with texture-analysis techniques to differentiate non-invasively benign versus malignant breast lesions. Ultrasound B-mode images and radiofrequency data were acquired from 78 patients with suspicious breast lesions. QUS spectral-analysis techniques were performed on radiofrequency data to generate parametric maps of mid-band fit, spectral slope, spectral intercept, spacing among scatterers, average scatterer diameter, and average acoustic concentration. Texture-analysis techniques were applied to determine imaging biomarkers consisting of mean, contrast, correlation, energy and homogeneity features of parametric maps. These biomarkers were utilized to classify benign versus malignant lesions with leave-one-patient-out cross-validation. Results were compared to histopathology findings from biopsy specimens and radiology reports on MR images to evaluate the accuracy of technique. Among the biomarkers investigated, one mean-value parameter and 14 textural features demonstrated statistically significant differences (p feature selection method could classify the legions with a sensitivity of 96%, a specificity of 84%, and an AUC of 0.97. Findings from this study pave the way towards adapting novel QUS-based frameworks for breast cancer screening and rapid diagnosis in clinic.

  8. Radiologists' Performance for Detecting Lesions and the Interobserver Variability of Automated Whole Breast Ultrasound

    International Nuclear Information System (INIS)

    Kim, Sung Hun; Kang, Bong Joo; Choi, Byung Gil; Choi, Jae Jung; Lee, Ji Hye; Song, Byung Joo; Choe, Byung Joo; Park, Sarah; Kim, Hyunbin

    2013-01-01

    To compare the detection performance of the automated whole breast ultrasound (AWUS) with that of the hand-held breast ultrasound (HHUS) and to evaluate the interobserver variability in the interpretation of the AWUS. AWUS was performed in 38 breast cancer patients. A total of 66 lesions were included: 38 breast cancers, 12 additional malignancies and 16 benign lesions. Three breast radiologists independently reviewed the AWUS data and analyzed the breast lesions according to the BI-RADS classification. The detection rate of malignancies was 98.0% for HHUS and 90.0%, 88.0% and 96.0% for the three readers of the AWUS. The sensitivity and the specificity were 98.0% and 62.5% in HHUS, 90.0% and 87.5% for reader 1, 88.0% and 81.3% for reader 2, and 96.0% and 93.8% for reader 3, in AWUS. There was no significant difference in the radiologists' detection performance, sensitivity and specificity (p > 0.05) between the two modalities. The interobserver agreement was fair to good for the ultrasonographic features, categorization, size, and the location of breast masses. AWUS is thought to be useful for detecting breast lesions. In comparison with HHUS, AWUS shows no significant difference in the detection rate, sensitivity and the specificity, with high degrees of interobserver agreement

  9. Radiologists' Performance for Detecting Lesions and the Interobserver Variability of Automated Whole Breast Ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hun; Kang, Bong Joo; Choi, Byung Gil; Choi, Jae Jung; Lee, Ji Hye [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Song, Byung Joo; Choe, Byung Joo [Department of General Surgery, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Park, Sarah [Department of Internal Medicine, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Kim, Hyunbin [CMC Clinical Research Coordinating Center, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of)

    2013-07-01

    To compare the detection performance of the automated whole breast ultrasound (AWUS) with that of the hand-held breast ultrasound (HHUS) and to evaluate the interobserver variability in the interpretation of the AWUS. AWUS was performed in 38 breast cancer patients. A total of 66 lesions were included: 38 breast cancers, 12 additional malignancies and 16 benign lesions. Three breast radiologists independently reviewed the AWUS data and analyzed the breast lesions according to the BI-RADS classification. The detection rate of malignancies was 98.0% for HHUS and 90.0%, 88.0% and 96.0% for the three readers of the AWUS. The sensitivity and the specificity were 98.0% and 62.5% in HHUS, 90.0% and 87.5% for reader 1, 88.0% and 81.3% for reader 2, and 96.0% and 93.8% for reader 3, in AWUS. There was no significant difference in the radiologists' detection performance, sensitivity and specificity (p > 0.05) between the two modalities. The interobserver agreement was fair to good for the ultrasonographic features, categorization, size, and the location of breast masses. AWUS is thought to be useful for detecting breast lesions. In comparison with HHUS, AWUS shows no significant difference in the detection rate, sensitivity and the specificity, with high degrees of interobserver agreement.

  10. A case of recurrence-mimicking charcoal granuloma in a breast cancer patient: Ultrasound,CT, PET/CT and breast-specific gamma imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dae Woong; Park, Ji Yeon; Park, Noh Hyuck; Kim, Seon Jeong; Shin, Hyuck Jai; Lee, Jeong Ju [Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of); Yi, Seong Yoon [Div. of Hematology-Oncology, Dept. of Internal Medicine, Inje University Ilsan Paik Hospital, Goyang (Korea, Republic of)

    2016-07-15

    Charcoal remains stable without causing a foreign body reaction and it may be used for preoperative localization of a non-palpable breast mass. However, cases of post-charcoal-marking granuloma have only rarely been reported in the breast, and a charcoal granuloma can be misdiagnosed as malignancy. Herein, we report the ultrasound, computed tomography (CT), 18F-fluorodeoxyglucose-positron emission tomography/CT, and breast-specific gamma imaging findings of recurrence-mimicking charcoal granuloma after breast conserving surgery, following localization with charcoal in a breast cancer patient.

  11. An iterated Laplacian based semi-supervised dimensionality reduction for classification of breast cancer on ultrasound images.

    Science.gov (United States)

    Liu, Xiao; Shi, Jun; Zhou, Shichong; Lu, Minhua

    2014-01-01

    The dimensionality reduction is an important step in ultrasound image based computer-aided diagnosis (CAD) for breast cancer. A newly proposed l2,1 regularized correntropy algorithm for robust feature selection (CRFS) has achieved good performance for noise corrupted data. Therefore, it has the potential to reduce the dimensions of ultrasound image features. However, in clinical practice, the collection of labeled instances is usually expensive and time costing, while it is relatively easy to acquire the unlabeled or undetermined instances. Therefore, the semi-supervised learning is very suitable for clinical CAD. The iterated Laplacian regularization (Iter-LR) is a new regularization method, which has been proved to outperform the traditional graph Laplacian regularization in semi-supervised classification and ranking. In this study, to augment the classification accuracy of the breast ultrasound CAD based on texture feature, we propose an Iter-LR-based semi-supervised CRFS (Iter-LR-CRFS) algorithm, and then apply it to reduce the feature dimensions of ultrasound images for breast CAD. We compared the Iter-LR-CRFS with LR-CRFS, original supervised CRFS, and principal component analysis. The experimental results indicate that the proposed Iter-LR-CRFS significantly outperforms all other algorithms.

  12. Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy

    Science.gov (United States)

    2018-01-01

    Ultrasound (US)-guided breast biopsy has become the main method for diagnosing breast pathology, and it has a high diagnostic accuracy, approaching that of open surgical biopsy. However, methods for confirming adequate lesion retrieval after US-guided biopsy are relatively limited and false-negative results are unavoidable. Determining imaging-pathology concordance after US-guided biopsy is essential for validating the biopsy result and providing appropriate management. In this review article, we briefly present the results of US-guided breast biopsy; describe general aspects to consider when establishing imaging-pathology concordance; and review the various categories of imaging-pathology correlations and corresponding management strategies. PMID:29169231

  13. Role of qualitative elastography in ultrasound diagnosis of small benign Doppler nonvascular breast lesions in patients with hypothyroidism

    Directory of Open Access Journals (Sweden)

    A. B. Abduraimov

    2014-01-01

    Full Text Available The article describes a role of qualitative elastography in ultrasound diagnosis small benign Doppler nonvascular lesions in patients withhypothyroidism. In 2010–2013 the study included 319 women aged 20 to 85 years who underwent breast ultrasound (US with qualitative elastography and mammography. Breast US with qualitative elastography usage is advisable combination for small dopplerographic avascular mass larger than 5 mm, both in patients with and without hypothyroidism. Breast US with qualitative elastography is more effective in patients without hypothyroidism than in patients with hypothyroidism.

  14. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    Science.gov (United States)

    Dang, Jun; Frisch, Benjamin; Lasaygues, Philippe; Zhang, Dachun; Tavernier, Stefaan; Felix, Nicolas; Lecoq, Paul; Auffray, Etiennette; Varela, Joao; Mensah, Serge; Wan, Mingxi

    2011-06-01

    Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allows labeling the different tissues in the phantom with different concentrations of FDG. The phantom was imaged with a whole-body PET/CT and with the Supersonic Imagine Aixplorer system. This system allows both B-mode US and shear wave elastographic imaging. US elastography is a new imaging method for displaying the tissue elasticity distribution. It was shown to be useful in breast imaging. We also tested the phantom with static elastography. A 6D magnetic positioning system allows fusing the images obtained with the two modalities. ClearPEM-Sonic is a project of the Crystal Clear Collaboration and the European Centre for Research on Medical Imaging (CERIMED).

  15. Breast Density Awareness and Knowledge, and Intentions for Breast Cancer Screening in a Diverse Sample of Women Age Eligible for Mammography.

    Science.gov (United States)

    Santiago-Rivas, Marimer; Benjamin, Shayna; Andrews, Janna Z; Jandorf, Lina

    2017-08-14

    The objectives of this study were to assess breast density knowledge and breast density awareness, and to identify information associated with intention to complete routine and supplemental screening for breast cancer in a diverse sample of women age eligible for mammography. We quantitatively (self-report) assessed breast density awareness and knowledge (N = 264) in black (47.7%), Latina (35.2%), and white (17%) women recruited online and in the community. Most participants reported having heard about breast density (69.2%); less than one third knew their own breast density status (30.4%). Knowing their own breast density, believing that women should be notified of their breast density in their mammogram report, and feeling informed if being provided this information are associated with likelihood of completing mammogram. Intending mammogram completion and knowledge regarding the impact of breast density on mammogram accuracy are associated with likelihood of completing supplemental ultrasound tests of the breast. These findings help inform practitioners and policy makers about information and communication factors that influence breast cancer screening concerns and decisions. Knowing this information should prepare practitioners to better identify women who may have not been exposed to breast density messages.

  16. Comparison of the Diagnostic Performance of Power Doppler Ultrasound and a New Microvascular Doppler Ultrasound Technique (AngioPLUS) for Differentiating Benign and Malignant Breast Masses.

    Science.gov (United States)

    Jung, Hae Kyoung; Park, Ah Young; Ko, Kyung Hee; Koh, Jieun

    2018-03-12

    This study was performed to compare the diagnostic performance of power Doppler ultrasound (US) and a new microvascular Doppler US technique (AngioPLUS; SuperSonic Imagine, Aix-en-Provence, France) for differentiating benign and malignant breast masses. Power Doppler US and AngioPLUS findings were available in 124 breast masses with confirmed pathologic results (benign, 80 [64.5%]; malignant, 44 [35.5%]). The diagnostic performance of each tool was calculated to distinguish benign from malignant masses using a receiver operating characteristic curve analysis and compared. The area under the curve showed that AngioPLUS was superior to power Doppler US in differentiating benign from malignant breast masses, but the difference was not statistically significant. © 2018 by the American Institute of Ultrasound in Medicine.

  17. Vitamin C supplement intake and postmenopausal breast cancer risk: interaction with dietary vitamin C.

    Science.gov (United States)

    Cadeau, Claire; Fournier, Agnès; Mesrine, Sylvie; Clavel-Chapelon, Françoise; Fagherazzi, Guy; Boutron-Ruault, Marie-Christine

    2016-07-01

    Experimental and epidemiologic studies have yielded conflicting results on the relation between vitamin C intake and breast cancer risk. We investigated the relation between vitamin C supplement intake and breast cancer risk while considering dietary vitamin C intake. Between 1995 and 2008, 2482 invasive breast cancer cases occurred in 57,403 postmenopausal women from the Etude Epidémiologique auprès de femmes de la Mutuelle Générale de l'Education Nationale (E3N) prospective cohort during 581,085 person-years. We estimated vitamin C intake from foods with the use of a validated food-frequency questionnaire that was sent to subjects in 1993-1995 and vitamin C supplement use via questionnaires sent in 1995, 2000, 2002, and 2005. Multivariable HRs (95% CIs) for primary invasive breast cancer were estimated with the use of Cox regression models. All statistical tests were 2-sided. Vitamin C supplement use (ever compared with never) was not associated with breast cancer risk overall; it was associated with higher breast cancer risk in women in the fourth quartile of vitamin C intake from foods (HR: 1.32; 95% CI: 1.04, 1.67) but not in other quartiles of dietary vitamin C intake (P-interaction = 0.03). We observed that vitamin C supplement use was associated with increased postmenopausal breast cancer risk in women with high vitamin C intake from foods. Our data suggest a potential U- or J-shaped relation between total vitamin C intake and postmenopausal breast cancer risk that deserves further investigation. © 2016 American Society for Nutrition.

  18. Preoperative estimation of the pathological breast tumour size by physical examination, mammography and ultrasound: a prospective study on 105 invasive tumours

    International Nuclear Information System (INIS)

    Bosch, Anne M.; Kessels, Alfons G.H.; Beets, Geerard L.; Rupa, Jan D.; Koster, Dick; Engelshoven, Jos M.A. van; Meyenfeldt, Maarten F. von

    2003-01-01

    Objective: The clinical breast tumour size can be assessed preoperatively by physical examination, mammography and ultrasound. At present it is not clear which modality correlates best with the histological invasive breast tumour size. This prospective study aims to determine the most accurate clinical method (physical examination, mammography or ultrasound) to predict the histological invasive tumour size preoperatively. Methods and patients: Between October 1999 and August 2000, 96 women with 105 invasive malignant breast tumours were included in this study. All patients underwent excision and the tumour size was measured on histology. Tumour size was measured by all three modalities in 73 cases. Results were evaluated by calculating correlation coefficients. The examination modalities presenting the best estimation of the pathological tumour size were used in a stepwise linear regression analysis to construct a formula predicting the pathological tumour size from the result of the various diagnostic modalities. Results: The correlation coefficient between ultrasound and pathological size (r=0.68) was significantly better than the correlations between physical examination and pathological size (r=0.42) and mammographic and pathological size (r=0.44). Physical examination overestimates and ultrasound underestimates breast tumour classification. The most accurate prediction formula was: Pathological tumour size (mm) equals sonographic tumour size (mm)+3 mm. Conclusion: When comparing physical examination, mammography and ultrasound for the prediction of the pathological size of a malignant breast tumour, ultrasound is the best predictor. The ensuing regression formula determines pathological size as tumour size by ultrasound+3 mm. However, with the wide 95% confidence interval of ±11 mm, it remains difficult to predict the exact pathological size for an individual invasive breast tumour. A small deviation in millimetres of the tumour size could lead to a change in

  19. Sparse Representation Based Multi-Instance Learning for Breast Ultrasound Image Classification

    Directory of Open Access Journals (Sweden)

    Lu Bing

    2017-01-01

    Full Text Available We propose a novel method based on sparse representation for breast ultrasound image classification under the framework of multi-instance learning (MIL. After image enhancement and segmentation, concentric circle is used to extract the global and local features for improving the accuracy in diagnosis and prediction. The classification problem of ultrasound image is converted to sparse representation based MIL problem. Each instance of a bag is represented as a sparse linear combination of all basis vectors in the dictionary, and then the bag is represented by one feature vector which is obtained via sparse representations of all instances within the bag. The sparse and MIL problem is further converted to a conventional learning problem that is solved by relevance vector machine (RVM. Results of single classifiers are combined to be used for classification. Experimental results on the breast cancer datasets demonstrate the superiority of the proposed method in terms of classification accuracy as compared with state-of-the-art MIL methods.

  20. M2 FILTER FOR SPECKLE NOISE SUPPRESSION IN BREAST ULTRASOUND IMAGES

    Directory of Open Access Journals (Sweden)

    E.S. Samundeeswari

    2016-11-01

    Full Text Available Breast cancer, commonly found in women is a serious life threatening disease due to its invasive nature. Ultrasound (US imaging method plays an effective role in screening early detection and diagnosis of Breast cancer. Speckle noise generally affects medical ultrasound images and also causes a number of difficulties in identifying the Region of Interest. Suppressing speckle noise is a challenging task as it destroys fine edge details. No specific filter is designed yet to get a noise free BUS image that is contaminated by speckle noise. In this paper M2 filter, a novel hybrid of linear and nonlinear filter is proposed and compared to other spatial filters with 3×3 kernel size. The performance of the proposed M2 filter is measured by statistical quantity parameters like MSE, PSNR and SSI. The experimental analysis clearly shows that the proposed M2 filter outperforms better than other spatial filters by 2% high PSNR values with regards to speckle suppression.

  1. Sparse Representation Based Multi-Instance Learning for Breast Ultrasound Image Classification.

    Science.gov (United States)

    Bing, Lu; Wang, Wei

    2017-01-01

    We propose a novel method based on sparse representation for breast ultrasound image classification under the framework of multi-instance learning (MIL). After image enhancement and segmentation, concentric circle is used to extract the global and local features for improving the accuracy in diagnosis and prediction. The classification problem of ultrasound image is converted to sparse representation based MIL problem. Each instance of a bag is represented as a sparse linear combination of all basis vectors in the dictionary, and then the bag is represented by one feature vector which is obtained via sparse representations of all instances within the bag. The sparse and MIL problem is further converted to a conventional learning problem that is solved by relevance vector machine (RVM). Results of single classifiers are combined to be used for classification. Experimental results on the breast cancer datasets demonstrate the superiority of the proposed method in terms of classification accuracy as compared with state-of-the-art MIL methods.

  2. In vivo breast sound-speed imaging with ultrasound tomography

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Li, Cuiping [KARMANOS CANCER INSTITUTE; Duric, Neb [KARMANOS CANCER INSTITUTE; Littrup, Peter [KARMONOS CANCER INSTITUTE

    2009-01-01

    We discuss a bent-ray ultrasound tomography algorithm with total-variation (TV) regularization. We have applied this algorithm to 61 in vivo breast datasets collected with our in-house clinical prototype for imaging sound-speed distributions in the breast. Our analysis showed that TV regularization could preserve sharper lesion edges than the classic Tikhonov regularization. Furthermore, the image quality of our TV bent-ray sound-speed tomograms was superior to that of the straight-ray counterparts for all types of breasts within BI-RADS density categories 1-4. For all four breast types from fatty to dense, the improvements for average sharpness (in the unit of (m{center_dot} s) {sup -1}) of lesion edges in our TV bent-ray tomograms are between 2.1 to 3.4 fold compared to the straight ray tomograms. Reconstructed sound-speed tomograms illustrated that our algorithm could successfully image fatty and glandular tissues within the breast. We calculated the mean sound-speed values for fatty tissue and breast parenchyma as 1422 {+-} 9 mls (mean{+-} SD) and1487 {+-} 21 mls, respectively. Based on 32 lesions in a cohort of 61 patients, we also found that the mean sound-speed for malignant breast lesions (1548{+-}17 mls) was higher, on average, than that of benign ones (1513{+-}27 mls) (one-sided pbreast density (, and therefore, breast cancer risk), as well as detect and help differentiate breast lesions. Finally, our sound-speed tomograms may also be a useful tool to monitor clinical response of breast cancer patients to neo-adjuvant chemotherapy.

  3. Detection of axillary lymph node metastases in breast carcinoma by technetium-99m sestamibi breast scintigraphy, ultrasound and conventional mammography

    International Nuclear Information System (INIS)

    Lam, W.W.M.; Yang, W.T.; Chan, Y.L.; Stewart, I.E.T.; Metreweli, C.; King, W.

    1996-01-01

    Axillary lymph node status is important in the staging of breast carcinoma. To evaluate the accuracy of technetium-99m sestamibi breast scintigraphy in detecting metastatic axillary lymph nodes as compared with other accepted imaging modalities, we performed 99m Tc-sestamibi breast scintigraphy, conventional mammography and ultrasound in 36 patients with primary untreated breast cardinoma. With histopathology as the gold standard, 99m Tc-sestamibi breast scintigraphy was found to yield true-positive results in 7 of 11 cases (64%) of axillary lymph nodes metastases and true-negative results in 18 of 20 cases (90%); it has an accuracy of 81%, a positive predictive value of 77.8% and a negative predicive value of 81.8%. (orig.)

  4. Diagnostic value of breast ultrasound in mammography BI-RADS 0 and clinically indeterminate or suspicious of malignancy breast lesions

    Directory of Open Access Journals (Sweden)

    Dobrosavljević Aleksandar

    2016-01-01

    Full Text Available Background/Aim. Not only that ultrasound makes the difference between cystic and solid changes in breast tissue, as it was the case at the beginning of its use, but it also makes the differential diagnosis in terms of benign-malignant. The aim of this study was to assess the role of sonography in the diagnosis of palpable breast masses according to the American College of Radiology Ultrasonographic Breast Imaging Reporting and Data System (BI-RADS and to correlate the BI-RADS 4 and BI-RADS 5 category with pathohistological findings. Methods. A retrospective study was conducted with the breast sonograms of 30 women presented with palpable breast masses found to be mammography category BI-RADS 0 and ultrasonographic BI-RADS categories 4 and 5. The sonographic categories were correlated with pathohistological findings. Results. Surgical biopsy in 30 masses revealed: malignancy (56.7%, fibroadenoma (26.7%, fibrocystic dysplasia with/without atypia (10%, lipoma (3.3% and intramammary lymph node (3.3%. Correlation between BI-RADS categories and pathohistological findings was found (p < 0.05. All BI-RADS 5 masses were malignant, while in BI-RADS 4A category fibroadenomas dominated. A total of 53.8% of all benign lesions were found in women 49 years of age or younger as compared with 35.3% of all malignancies in this group (p < 0.05. Conclusion. Ultrasonography BI-RADS improved classification of breast masses. The ultrasound BI-RADS 4 (A, B, C and BI-RADS 5 lesions should be worked-up with biopsy.

  5. Mammographic and ultrasound features of invasive lobular carcinoma of the breast

    International Nuclear Information System (INIS)

    Porter, Alan J.; Evans, Elizabeth B.; Foxcraft, Loani M.; Simpson, Peter T.; Lakhani, Sunil R.

    2014-01-01

    Invasive lobular cancer (ILC) is an important contributor to false negative mammography. This study aims to assess the value of digital mammography and to identify imaging features that could assist the radiologist to suggest the diagnosis of ILC prior to biopsy. Three hundred sixty-one cases of pure ILC diagnosed at the Wesley Breast Clinic during the period 1995–2010 were reviewed by one of the authors (AP). Radiological features were categorized, and clinical features and needle sampling results were recorded. Mammography was negative in 29.9% of ILCs. The commonest positive finding was a localized spiculated mass (41.8%). Thirty-four point nine per cent of lesions were visible in only one view, usually cranio-caudal. Calcification was not a feature of ILC. The use of digital mammography in 30% of cases did not decrease the false negative rate for ILC. Breast ultrasound (BUS) showed an abnormality in 97.8%, most commonly a localized irregular hypoechoic mass with shadowing. Digital mammography does not reduce false negative mammography in ILC. The poor visibility of ILCs may be partly related to their low density (mass/unit volume). ILCs may sometimes be poor attenuators of X-rays but excellent attenuators of ultrasound, causing marked acoustic shadowing. Bilateral whole BUS has a very low false negative rate in experienced hands and is mandatory in symptomatic women. The combination of poor visibility on mammography with high visibility on ultrasound, as well as certain characteristic ultrasound appearances of ILC, may enable the radiologist to suggest ILC as a diagnostic possibility, prior to biopsy.

  6. Multimodal ultrasound tomography for breast imaging: a prospective study of clinical feasibility.

    Science.gov (United States)

    Forte, S; Dellas, S; Stieltjes, B; Bongartz, B

    2017-01-01

    To describe the clinical set-up and evaluate the feasibility of multimodal ultrasound tomography (MUT) for breast imaging. Thirty-two consecutive patients referred for breast imaging and 24 healthy volunteers underwent MUT. In the 32 patients, the examination discomfort was compared to that of mammography (n = 31), handheld ultrasound (HUS) (n = 27) and magnetic resonance imaging (MRI) (n = 4) on a scale from 1 (lowest discomfort) to 10 (highest discomfort). MUT investigation time was recorded. Findings automatically detected by MUT were correlated with conventional imaging and biopsy results. Breast MUT was well tolerated by all 56 participants; 55 bilateral exams were uneventful. During one exam, the digitalisation card failed and the exam was successfully repeated within three days. Mean examination discomfort was 1.6 (range = 1-5) for MUT, 1.5 (range = 1-5) for HUS, 5.3 (range = 3-7) for MRI, and 6.3 (range = 1-10) for mammography. MUT examination time was 38 ± 6 min (mean ± standard deviation). In the patients referred for breast imaging, MUT detected four lesions and indicated malignancy in three of these cases. These findings were confirmed by additional imaging and biopsy. MUT is feasible in a clinical context considering examination time and patient acceptance. These interesting initial diagnostic findings warrant further studies.

  7. Staging primary breast cancer. Are there tumour pathological features that correlate with a false-negative axillary ultrasound?

    International Nuclear Information System (INIS)

    Johnson, S.; Brown, S.; Porter, G.; Steel, J.; Paisley, K.; Watkins, R.; Holgate, C.

    2011-01-01

    Aim: To investigate whether the histopathological characteristics of primary breast cancer tumours could predict the likelihood of false-negative axillary ultrasound. Materials and methods: Screening and symptomatic patients were identified from pathology records and imaging and pathology records reviewed. True and false-negative axillary staging ultrasound groups were compared statistically in terms of tumour size, pathological type and grade, lymphovascular invasion, and oestrogen receptor (ER) status. Results: Of 155 women with normal ultrasounds, 45 (29%) were node positive at axillary surgery. Breast tumour size was significantly different with the average size smaller in the true-negative group: 21 versus 30 mm (p < 0.02). The histological type varied significantly between the groups, with more lobular carcinomas in the false-negative group [6/110 (5%) versus 6/45 (13%), p < 0.001]. The false-negative group was also more likely to show lymphovascular invasion in the breast [6/110 (5%) versus 14/45 (31%), p < 0.001]. There was no significant difference in tumour grade or ER status. Conclusion: The present study has found significant differences in tumour characteristics between women with true-negative and false-negative axillary staging ultrasound in terms of size, primary tumour histological type and presence of lymphovascular invasion. In particular, axillary ultrasound in primary lobular carcinoma may be less accurate and a negative result is more likely to be spurious than with primary ductal carcinomas.

  8. Supine breast US: how to correlate breast lesions from prone MRI.

    Science.gov (United States)

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato A; Angelelli, Giuseppe; Moschetta, Marco

    2016-01-01

    To evaluate spatial displacement of breast lesions from prone MR to supine ultrasound positions, and to determine whether the degree of displacement may be associated with breast density and lesion histotype. 380 patients underwent breast MR and second-look ultrasound. The MR and ultrasound lesion location within the breast gland, distances from anatomical landmarks (nipple, skin and pectoral muscle), spatial displacement (distance differences from the landmarks within the same breast region) and region displacement (breast region change) were prospectively evaluated. Differences between MR and ultrasound measurements, association between the degree of spatial displacement and both breast density and lesion histotypes were calculated. In 290/380 (76%) patients, 300 MR lesions were detected. 285/300 (95%) lesions were recognized on ultrasound. By comparing MR and ultrasound, spatial displacement occurred in 183/285 (64.3%) cases while region displacement in 102/285 (35.7%) cases with a circumferential movement along an arc centred on the nipple, having supine ultrasound as the reference standard. A significant association between the degree of lesion displacement and breast density was found (p < 0.00001) with a significant higher displacement in case of fatty breasts. No significant association between the degree of displacement and lesion histotype was found (p = 0.1). Lesion spatial displacement from MRI to ultrasound may occur especially in adipose breasts. Lesion-nipple distance and circumferential displacement from the nipple need to be considered for ultrasound lesion detection. Second-look ultrasound breast lesion detection could be improved by calculating the lesion-nipple distance and considering that spatial displacement from MRI occurs with a circumferential movement along an arc centred on the nipple.

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  10. How reassuring is a normal breast ultrasound in assessment of a screen-detected mammographic abnormality? A review of interval cancers after assessment that included ultrasound evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, M.L. [Breastscreen WA, Perth (Australia); Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth (Australia); Welman, C.J. [Breastscreen WA, Perth (Australia); Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth (Australia); Department of Radiology, Fremantle Hospital and Health Service, Fremantle (Australia); Celliers, L.M., E-mail: liesl.celliers@health.wa.gov.au [Department of Diagnostic and Interventional Radiology, Royal Perth Hospital, Perth (Australia); Department of Radiology, Fremantle Hospital and Health Service, Fremantle (Australia)

    2011-10-15

    Aim: To review factors resulting in a false-negative outcome or delayed cancer diagnosis in women recalled for further evaluation, including ultrasound, after an abnormal screening mammogram. Materials and methods: Of 646,692 screening mammograms performed between 1 January 1995 and 31 December 2004, 34,533 women were recalled for further assessment. Nine hundred and sixty-four interval cancers were reported in this period. Forty-six of these women had been recalled for further assessment, which specifically included ultrasound evaluation in the preceding 24 months, and therefore, met the inclusion criteria for this study. Screening mammograms, further mammographic views, ultrasound scans, clinical findings, and histopathology results were retrospectively reviewed by two consultant breast radiologists. Results: The interval cancer developed in the contralateral breast (n = 9), ipsilateral breast, but different site (n = 6), and ipsilateral breast at the same site (n = 31) as the abnormality for which they had recently been recalled. In the latter group, 10 were retrospectively classified as a false-negative outcome, nine had a delay in obtaining a biopsy, and 12 had a delay due to a non-diagnostic initial biopsy. Various factors relating to these outcomes are discussed. Conclusion: Out of 34,533 women who attended for an assessment visit and the 46 women who subsequently developed an interval breast cancer, 15 were true interval cancers, 10 had a false-negative assessment outcome, and 21 had a delay to cancer diagnosis on the basis of a number of factors. When there is discrepancy between the imaging and histopathology results, a repeat biopsy rather than early follow-up would have avoided a delay in some cases. A normal ultrasound examination should not deter the radiologist from proceeding to stereotactic biopsy, if the index mammographic lesion is suspicious of malignancy.

  11. A priori Prediction of Neoadjuvant Chemotherapy Response and Survival in Breast Cancer Patients using Quantitative Ultrasound.

    Science.gov (United States)

    Tadayyon, Hadi; Sannachi, Lakshmanan; Gangeh, Mehrdad J; Kim, Christina; Ghandi, Sonal; Trudeau, Maureen; Pritchard, Kathleen; Tran, William T; Slodkowska, Elzbieta; Sadeghi-Naini, Ali; Czarnota, Gregory J

    2017-04-12

    Quantitative ultrasound (QUS) can probe tissue structure and analyze tumour characteristics. Using a 6-MHz ultrasound system, radiofrequency data were acquired from 56 locally advanced breast cancer patients prior to their neoadjuvant chemotherapy (NAC) and QUS texture features were computed from regions of interest in tumour cores and their margins as potential predictive and prognostic indicators. Breast tumour molecular features were also collected and used for analysis. A multiparametric QUS model was constructed, which demonstrated a response prediction accuracy of 88% and ability to predict patient 5-year survival rates (p = 0.01). QUS features demonstrated superior performance in comparison to molecular markers and the combination of QUS and molecular markers did not improve response prediction. This study demonstrates, for the first time, that non-invasive QUS features in the core and margin of breast tumours can indicate breast cancer response to neoadjuvant chemotherapy (NAC) and predict five-year recurrence-free survival.

  12. Evaluation of an automated breast 3D-ultrasound system by comparing it with hand-held ultrasound (HHUS) and mammography.

    Science.gov (United States)

    Golatta, Michael; Baggs, Christina; Schweitzer-Martin, Mirjam; Domschke, Christoph; Schott, Sarah; Harcos, Aba; Scharf, Alexander; Junkermann, Hans; Rauch, Geraldine; Rom, Joachim; Sohn, Christof; Heil, Joerg

    2015-04-01

    Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology). Nine hundred and eighty three patients (=1,966 breasts) were enrolled in this monocentric, explorative and prospective cohort study. All examinations were analyzed blinded to the patients´ history and to the results of the routine imaging. The agreement of automated 3D-US with HHUS, mammography and the gold standard was assessed with kappa statistics. Sensitivity, specificity and positive and negative predictive value were calculated to assess the test performance. Blinded to the results of the gold standard the agreement between automated 3D-US and HHUS or mammography was fair, given by a Kappa coefficient of 0.31 (95% CI [0.26;0.36], p automated 3D-US the sensitivity improved to 84% (NPV = 99%, specificity = 85%). The results of this study let us suggest, that automated 3D-US might be a helpful new tool in breast imaging, especially in screening.

  13. Automated breast segmentation in ultrasound computer tomography SAFT images

    Science.gov (United States)

    Hopp, T.; You, W.; Zapf, M.; Tan, W. Y.; Gemmeke, H.; Ruiter, N. V.

    2017-03-01

    Ultrasound Computer Tomography (USCT) is a promising new imaging system for breast cancer diagnosis. An essential step before further processing is to remove the water background from the reconstructed images. In this paper we present a fully-automated image segmentation method based on three-dimensional active contours. The active contour method is extended by applying gradient vector flow and encoding the USCT aperture characteristics as additional weighting terms. A surface detection algorithm based on a ray model is developed to initialize the active contour, which is iteratively deformed to capture the breast outline in USCT reflection images. The evaluation with synthetic data showed that the method is able to cope with noisy images, and is not influenced by the position of the breast and the presence of scattering objects within the breast. The proposed method was applied to 14 in-vivo images resulting in an average surface deviation from a manual segmentation of 2.7 mm. We conclude that automated segmentation of USCT reflection images is feasible and produces results comparable to a manual segmentation. By applying the proposed method, reproducible segmentation results can be obtained without manual interaction by an expert.

  14. Technical Note: Multipurpose CT, ultrasound, and MRI breast phantom for use in radiotherapy and minimally invasive interventions

    Energy Technology Data Exchange (ETDEWEB)

    Ruschin, Mark, E-mail: Mark.Ruschin@sunnybrook.ca; Chin, Lee; Ravi, Ananth; McCann, Claire [Department of Medical Physics, Sunnybrook Odette Cancer Centre, Toronto, Ontario M4N 3M5, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Davidson, Sean R. H. [Techna Institute, University Health Network, Toronto, Ontario M5G 1P5 (Canada); Phounsy, William [Department of Physics, Ryerson University, Toronto, Ontario M5B 2K3 (Canada); Yoo, Tae Sun [Institute of Health Policy, University of Toronto, Toronto, Ontario M5T 3M6 (Canada); Pignol, Jean-Philippe [Department of Radiation Oncology, Erasmus MC Cancer Institute, 3075 EA Rotterdam (Netherlands)

    2016-05-15

    Purpose: To develop a multipurpose gel-based breast phantom consisting of a simulated tumor with realistic imaging properties in CT, ultrasound and MRI, or a postsurgical cavity on CT. Applications for the phantom include: deformable image registration (DIR) quality assurance (QA), autosegmentation validation, and localization testing and training for minimally invasive image-guided procedures such as those involving catheter or needle insertion. Methods: A thermoplastic mask of a typical breast patient lying supine was generated and then filled to make an array of phantoms. The background simulated breast tissue consisted of 32.4 g each of ballistic gelatin (BG) powder and Metamusil™ (MM) dissolved in 800 ml of water. Simulated tumors were added using the following recipe: 12 g of barium sulfate (1.4% v/v) plus 0.000 14 g copper sulfate plus 0.7 g of MM plus 7.2 g of BG all dissolved in 75 ml of water. The phantom was evaluated quantitatively in CT by comparing Hounsfield units (HUs) with actual breast tissue. For ultrasound and MRI, the phantoms were assessed based on subjective image quality and signal-difference to noise (SDNR) ratio, respectively. The stiffness of the phantom was evaluated based on ultrasound elastography measurements to yield an average Young’s modulus. In addition, subjective tactile assessment of phantom was performed under needle insertion. Results: The simulated breast tissue had a mean background value of 24 HU on CT imaging, which more closely resembles fibroglandular tissue (40 HU) as opposed to adipose (−100 HU). The tumor had a mean CT number of 45 HU, which yielded a qualitatively realistic image contrast relative to the background either as an intact tumor or postsurgical cavity. The tumor appeared qualitatively realistic on ultrasound images, exhibiting hypoechoic characteristics compared to background. On MRI, the tumor exhibited a SDNR of 3.7. The average Young’s modulus was computed to be 15.8 ± 0.7 kPa (1 SD

  15. Thermal therapy for breast tumors by using a cylindrical ultrasound phased array with multifocus pattern scanning: a preliminary numerical study

    International Nuclear Information System (INIS)

    Ho, C-S; Ju, K-C; Cheng, T-Y; Chen, Y-Y; Lin, W-L

    2007-01-01

    The purpose of this study is to investigate the feasibility of using a 1 MHz cylindrical ultrasound phased array with multifocus pattern scanning to produce uniform heating for breast tumor thermal therapy. The breast was submerged in water and surrounded by the cylindrical ultrasound phased array. A multifocus pattern was generated and electrically scanned by the phased array to enlarge the treatment lesion in single heating. To prevent overheating normal tissues, a large planning target volume (PTV) would be divided into several planes with several subunits on each plane and sequentially treated with a cooling phase between two successive heatings of the subunit. Heating results for different target temperatures (T tgt ), blood perfusion rates and sizes of the PTV have been studied. Furthermore, a superficial breast tumor with different water temperatures was also studied. Results indicated that a higher target temperature would produce a slightly larger thermal lesion, and a higher blood perfusion rate would not affect the heating lesion size but increase the heating time significantly. The acoustic power deposition and temperature elevations in ribs can be minimized by orienting the acoustic beam from the ultrasound phased array approximately parallel to the ribs. In addition, a large acoustic window on the convex-shaped breast surface for the proposed ultrasound phased array and the cooling effect of water would prevent the skin overheating for the production of a lesion at any desired location. This study demonstrated that the proposed cylindrical ultrasound phased array can provide effective heating for breast tumor thermal therapy without overheating the skin and ribs within a reasonable treatment time

  16. Background enhancement in breast MR: Correlation with breast density in mammography and background echotexture in ultrasound

    International Nuclear Information System (INIS)

    Ko, Eun Sook; Lee, Byung Hee; Choi, Hye Young; Kim, Rock Bum; Noh, Woo-Chul

    2011-01-01

    Objective: This study aimed to determine whether background enhancement on MR was related to mammographic breast density or ultrasonographic background echotexture in premenopausal and postmenopausal women. Materials and methods: We studied 142 patients (79 premenopausal, 63 postmenopausal) who underwent mammography, ultrasonography, and breast MR. We reviewed the mammography for overall breast density of the contralateral normal breast according to the four-point scale of the BI-RADS classification. Ultrasound findings were classified as homogeneous or heterogeneous background echotexture according to the BI-RADS lexicon. We rated background enhancement on a contralateral breast MR into four categories based on subtraction images: absent, mild, moderate, and marked. All imaging findings were interpreted independently by two readers without knowledge of menstrual status, imaging findings of other modalities. Results: There were significant differences between the premenopausal and postmenopausal group in distribution of mammographic breast density, ultrasonographic background echotexture, and degree of background enhancement. Regarding the relationship between mammographic density and background enhancement, there was no significant correlation. There was significant relationship between ultrasonographic background echotexture and background enhancement in both premenopausal and postmenopausal groups. Conclusion: There is a significant correlation between ultrasonographic background echotexture and background enhancement in MR regardless of menopausal status. Interpreting breast MR, or scheduling for breast MR of women showing heterogeneous background echotexture needs more caution.

  17. Supplemental Screening for Breast Cancer in Women With Dense Breasts: A Systematic Review for the U.S. Preventive Services Task Force.

    Science.gov (United States)

    Melnikow, Joy; Fenton, Joshua J; Whitlock, Evelyn P; Miglioretti, Diana L; Weyrich, Meghan S; Thompson, Jamie H; Shah, Kunal

    2016-02-16

    Screening mammography has lower sensitivity and specificity in women with dense breasts, who experience higher breast cancer risk. To perform a systematic review of reproducibility of Breast Imaging Reporting and Data System (BI-RADS) density categorization and test performance and clinical outcomes of supplemental screening with breast ultrasonography, magnetic resonance imaging (MRI), and digital breast tomosynthesis (DBT) in women with dense breasts and negative mammography results. MEDLINE, PubMed, EMBASE, and Cochrane database from January 2000 to July 2015. Studies reporting BI-RADS density reproducibility or supplemental screening results for women with dense breasts. Quality assessment and abstraction of 24 studies from 7 countries; 6 studies were good-quality. Three good-quality studies reported reproducibility of BI-RADS density; 13% to 19% of women were recategorized between "dense" and "nondense" at subsequent screening. Two good-quality studies reported that sensitivity of ultrasonography for women with negative mammography results ranged from 80% to 83%; specificity, from 86% to 94%; and positive predictive value (PPV), from 3% to 8%. The sensitivity of MRI ranged from 75% to 100%; specificity, from 78% to 94%; and PPV, from 3% to 33% (3 studies). Rates of additional cancer detection with ultrasonography were 4.4 per 1000 examinations (89% to 93% invasive); recall rates were 14%. Use of MRI detected 3.5 to 28.6 additional cancer cases per 1000 examinations (34% to 86% invasive); recall rates were 12% to 24%. Rates of cancer detection with DBT increased by 1.4 to 2.5 per 1000 examinations compared with mammography alone (3 studies). Recall rates ranged from 7% to 11%, compared with 7% to 17% with mammography alone. No studies examined breast cancer outcomes. Good-quality evidence was sparse. Studies were small and CIs were wide. Definitions of recall were absent or inconsistent. Density ratings may be recategorized on serial screening mammography

  18. Usefulness limitation of 3D-ultrasound diagnosis of breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, Yong Seok; Chung, Soo Young; Yang, Ik; Lee, Kyung Won; Kim, Hong Dae; Shin, Sang Joon; Chung, Bong Wha [College of Medicine, Hallym Univ., Seoul (Korea, Republic of)

    2001-09-01

    To compare 3D ultrasound (3D-US) with 2D ultrasound (2D-US) in terms of their usefulness and limitations in the diagnosis of breast masses. We obtained 2D and 3D US images of 37 breast lesions present in 20 cases of fibroadenoma, nine of cancer, and eight of fibrocystic disease proven in a total of 26 cases [ fibroadenoma (n=13), breast cancer (n=9), fibrocystic disease (n=4)] by histologic examination, and by clinical evaluation and clinical evaluation with sonographic imaging in eleven. When comparing 3D and 2D-US images we had no prior information regarding detection rate according to the size of lesions, whether or not internal and boundary echo patterns could be interpreted, accurate differentiation between tumorous and non-tumorous lesions, or the accuracy with which benign and malignant tumors could be differentiated. For lesions of 1 cm or less in diameter the detection rate of 3D-US was lower than that of 2D-US, but for lesions over 1 cm there was no difference between the two modalities. In fibroadenoma and breast cancer, 3D-US was more useful than 2D-US for the evaluation of both internal and boundary echo, but with fibrocystic disease and in the diagnosis of tumor/non-tumor, there was no significant difference. In breast cancer, however, 3D-US more accurately determined malignancy, and in fibroadenoma, because of the pseudospicule revealed by 3D-US, this modality was less exact in determining benignancy. In the evaluation of internal and boundary echo in breast mass diagnosis, 3D-US was more useful than its 2D counterpart. For lesions of 1 cm or less in diameter, however, the detection rate of 3D-US was more useful than its 2D counterpart. For lesions of 1 cm or less in diameter, however, the detection rate of 3D-US was low, and since in some benign cases a pseudospicule was apparent, the possibility of confusion with malignancy arose. For these reasons, the usefulness of 3D-US was limited.

  19. Usefulness limitation of 3D-ultrasound diagnosis of breast masses

    International Nuclear Information System (INIS)

    Cheon, Yong Seok; Chung, Soo Young; Yang, Ik; Lee, Kyung Won; Kim, Hong Dae; Shin, Sang Joon; Chung, Bong Wha

    2001-01-01

    To compare 3D ultrasound (3D-US) with 2D ultrasound (2D-US) in terms of their usefulness and limitations in the diagnosis of breast masses. We obtained 2D and 3D US images of 37 breast lesions present in 20 cases of fibroadenoma, nine of cancer, and eight of fibrocystic disease proven in a total of 26 cases [ fibroadenoma (n=13), breast cancer (n=9), fibrocystic disease (n=4)] by histologic examination, and by clinical evaluation and clinical evaluation with sonographic imaging in eleven. When comparing 3D and 2D-US images we had no prior information regarding detection rate according to the size of lesions, whether or not internal and boundary echo patterns could be interpreted, accurate differentiation between tumorous and non-tumorous lesions, or the accuracy with which benign and malignant tumors could be differentiated. For lesions of 1 cm or less in diameter the detection rate of 3D-US was lower than that of 2D-US, but for lesions over 1 cm there was no difference between the two modalities. In fibroadenoma and breast cancer, 3D-US was more useful than 2D-US for the evaluation of both internal and boundary echo, but with fibrocystic disease and in the diagnosis of tumor/non-tumor, there was no significant difference. In breast cancer, however, 3D-US more accurately determined malignancy, and in fibroadenoma, because of the pseudospicule revealed by 3D-US, this modality was less exact in determining benignancy. In the evaluation of internal and boundary echo in breast mass diagnosis, 3D-US was more useful than its 2D counterpart. For lesions of 1 cm or less in diameter, however, the detection rate of 3D-US was more useful than its 2D counterpart. For lesions of 1 cm or less in diameter, however, the detection rate of 3D-US was low, and since in some benign cases a pseudospicule was apparent, the possibility of confusion with malignancy arose. For these reasons, the usefulness of 3D-US was limited

  20. Ultrasound detection of nonpalpable mammographically occult malignancy

    International Nuclear Information System (INIS)

    Simpson, W.L.; Hermann, G.; Rausch, D.R.; Sherman, J.; Feig, S.A.; Bleiweiss, I.J.; Jaffer, S.

    2008-01-01

    To evaluate the prevalence of occult malignancy with screening breast ultrasound. All ultrasound-guided core needle breast biopsies performed between January 1, 1999, and June 30, 2001, were retrospectively reviewed. Lesions were identified during screening breast ultrasound in high-risk women with no mammographic or palpable abnormality in either breast, a unilateral mammographic or palpable abnormality in the contralateral breast, or a unilateral mammographic or palpable abnormality in a different quadrant of the same breast. All ultrasound-detected lesions were histologically verified. Six hundred and fifty-two women with a mean age of 49 years underwent 698 biopsies during the study period. Three hundred and forty-nine of these lesions were detected at screening breast ultrasound. Out of 349, 11 (3.2%) had a mammographically and clinically occult malignancy. Nine cancers were found in women with no mammographic or palpable abnormality. Two cancers were found in the same breast as the mammographic or palpable abnormality. None were found in the breast contralateral to a palpable or mammographic abnormality. Screening breast ultrasound of high-risk women has a similar detection rate for occult carcinoma as screening mammography, but has a low positive predictive value in cases where biopsy is performed. (author)

  1. What Help Could Ultrasound Elastography Give to the Diagnosis of Breast Papillary Lesions?

    Science.gov (United States)

    Li, Lu-Jing; Yao, Ji-Yi; Zhou, Xin-Chuan; Zhao, Xin-Bao; Zhong, Wen-Jing; Ou, Bing; Luo, Bao-Ming; Hao, Shao-Yun; Zhi, Hui

    2017-05-01

    On the basis of results of our previous studies and the findings of other scholars, the most common histologic type of false-positive diagnosis with strain elastography (SE) was papilloma. The objectives of our study were to evaluate whether SE could contribute to conventional ultrasound differentiation between benign and malignant papillary lesions and between papillary lesions and other common benign breast lesions. Data on 89 papillary lesions at our hospital, including 74 benign and 15 malignant papillary lesions, were included in our study. In addition, 198 non-papillary benign tumors were selected as the control group, including 126 fibroadenomas and 72 cases of fibrocystic mastopathy. All patients gave written informed consent. All patients with breast lesions underwent conventional ultrasound and SE examination. Breast Imaging Recording and Data System (BI-RADS) category and SE score were compared with respect to sensitivity, specificity and accuracy in differentiating between benign and malignant papillary lesions. We then explored the possibility of using BI-RADS combined with SE to differentiate papillary lesions from non-papillary benign tumors. For differentiating between benign and malignant papillary lesions, the area under the receiver operating characteristic curve (AUC) of BI-RADS was 0.568, whereas the AUC values of SE score, strain ratio and BI-RADS combined with SE were 0.517, 0.584 and 0.509, respectively (p > 0.05). For differentiating between papillary lesions and non-papillary benign lesions, the AUC of BI-RADS combined with SE was 0.835, which was higher than the values for BI-RADS (0.775) and SE (SE score: 0.648, strain ratio: 0.661) (p breast papillary lesions from non-papillary benign lesions. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  2. Breast Metastases from Extramammary Malignancies: Typical and Atypical Ultrasound Features

    Energy Technology Data Exchange (ETDEWEB)

    Mun, Sung Hee [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 135-710 (Korea, Republic of); Department of Radiology, Catholic University of Daegu College of Medicine, Daegu 712-702 (Korea, Republic of); Ko, Eun Young; Han, Boo-Kyung; Shin, Jung Hee [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 135-710 (Korea, Republic of); Kim, Suk Jung [Department of Radiology, Inje University College of Medicine, Busan Paik Hospital, Busan 614-735 (Korea, Republic of); Cho, Eun Yoon [Department of Pathology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 135-710 (Korea, Republic of)

    2014-07-01

    Breast metastases from extramammary malignancies are uncommon. The most common sources are lymphomas/leukemias and melanomas. Some of the less common sources include carcinomas of the lung, ovary, and stomach, and infrequently, carcinoid tumors, hypernephromas, carcinomas of the liver, tonsil, pleura, pancreas, cervix, perineum, endometrium and bladder. Breast metastases from extramammary malignancies have both hematogenous and lymphatic routes. According to their routes, there are common radiological features of metastatic diseases of the breast, but the features are not specific for metastases. Typical ultrasound (US) features of hematogenous metastases include single or multiple, round to oval shaped, well-circumscribed hypoechoic masses without spiculations, calcifications, or architectural distortion; these masses are commonly located superficially in subcutaneous tissue or immediately adjacent to the breast parenchyma that is relatively rich in blood supply. Typical US features of lymphatic breast metastases include diffusely and heterogeneously increased echogenicities in subcutaneous fat and glandular tissue and a thick trabecular pattern with secondary skin thickening, lymphedema, and lymph node enlargement. However, lesions show variable US features in some cases, and differentiation of these lesions from primary breast cancer or from benign lesions is difficult. In this review, we demonstrate various US appearances of breast metastases from extramammary malignancies as typical and atypical features, based on the results of US and other imaging studies performed at our institution. Awareness of the typical and atypical imaging features of these lesions may be helpful to diagnose metastatic lesions of the breast.

  3. Breast Metastases from Extramammary Malignancies: Typical and Atypical Ultrasound Features

    International Nuclear Information System (INIS)

    Mun, Sung Hee; Ko, Eun Young; Han, Boo-Kyung; Shin, Jung Hee; Kim, Suk Jung; Cho, Eun Yoon

    2014-01-01

    Breast metastases from extramammary malignancies are uncommon. The most common sources are lymphomas/leukemias and melanomas. Some of the less common sources include carcinomas of the lung, ovary, and stomach, and infrequently, carcinoid tumors, hypernephromas, carcinomas of the liver, tonsil, pleura, pancreas, cervix, perineum, endometrium and bladder. Breast metastases from extramammary malignancies have both hematogenous and lymphatic routes. According to their routes, there are common radiological features of metastatic diseases of the breast, but the features are not specific for metastases. Typical ultrasound (US) features of hematogenous metastases include single or multiple, round to oval shaped, well-circumscribed hypoechoic masses without spiculations, calcifications, or architectural distortion; these masses are commonly located superficially in subcutaneous tissue or immediately adjacent to the breast parenchyma that is relatively rich in blood supply. Typical US features of lymphatic breast metastases include diffusely and heterogeneously increased echogenicities in subcutaneous fat and glandular tissue and a thick trabecular pattern with secondary skin thickening, lymphedema, and lymph node enlargement. However, lesions show variable US features in some cases, and differentiation of these lesions from primary breast cancer or from benign lesions is difficult. In this review, we demonstrate various US appearances of breast metastases from extramammary malignancies as typical and atypical features, based on the results of US and other imaging studies performed at our institution. Awareness of the typical and atypical imaging features of these lesions may be helpful to diagnose metastatic lesions of the breast

  4. A multicenter hospital-based diagnosis study of automated breast ultrasound system in detecting breast cancer among Chinese women.

    Science.gov (United States)

    Zhang, Xi; Lin, Xi; Tan, Yanjuan; Zhu, Ying; Wang, Hui; Feng, Ruimei; Tang, Guoxue; Zhou, Xiang; Li, Anhua; Qiao, Youlin

    2018-04-01

    The automated breast ultrasound system (ABUS) is a potential method for breast cancer detection; however, its diagnostic performance remains unclear. We conducted a hospital-based multicenter diagnostic study to evaluate the clinical performance of the ABUS for breast cancer detection by comparing it to handheld ultrasound (HHUS) and mammography (MG). Eligible participants underwent HHUS and ABUS testing; women aged 40-69 years additionally underwent MG. Images were interpreted using the Breast Imaging Reporting and Data System (BI-RADS). Women in the BI-RADS categories 1-2 were considered negative. Women classified as BI-RADS 3 underwent magnetic resonance imaging to distinguish true- and false-negative results. Core aspiration or surgical biopsy was performed in women classified as BI-RADS 4-5, followed by a pathological diagnosis. Kappa values and agreement rates were calculated between ABUS, HHUS and MG. A total of 1,973 women were included in the final analysis. Of these, 1,353 (68.6%) and 620 (31.4%) were classified as BI-RADS categories 1-3 and 4-5, respectively. In the older age group, the agreement rate and Kappa value between the ABUS and HHUS were 94.0% and 0.860 (P<0.001), respectively; they were 89.2% and 0.735 (P<0.001) between the ABUS and MG, respectively. Regarding consistency between imaging and pathology results, 78.6% of women classified as BI-RADS 4-5 based on the ABUS were diagnosed with precancerous lesions or cancer; which was 7.2% higher than that of women based on HHUS. For BI-RADS 1-2, the false-negative rates of the ABUS and HHUS were almost identical and were much lower than those of MG. We observed a good diagnostic reliability for the ABUS. Considering its performance for breast cancer detection in women with high-density breasts and its lower operator dependence, the ABUS is a promising option for breast cancer detection in China.

  5. Characterization of Breast Masses Using a New Method of Ultrasound Contrast Agent Imaging in 3D Mapping of Vascular Anomalies

    National Research Council Canada - National Science Library

    LeCarpentier, Gerald

    2002-01-01

    .... The purpose of this work is to develop an innovative dual-transducer method to control the destruction and imaging of ultrasound contrast during 3D ultrasound scanning of suspicious breast masses...

  6. The Automated Breast Volume Scanner (ABVS: initial experiences in lesion detection compared with conventional handheld B-mode ultrasound: a pilot study of 50 cases

    Directory of Open Access Journals (Sweden)

    Wojcinski S

    2011-10-01

    Full Text Available Sebastian Wojcinski1, Andre Farrokh1, Ursula Hille2, Jakub Wiskirchen3, Samuel Gyapong1, Amr A Soliman1,4, Friedrich Degenhardt1, Peter Hillemanns21Department of OB/GYN, Franziskus Hospital, Bielefeld, Germany; 2Department of OB/GYN, Hannover Medical School, Hannover, Germany; 3Department of Radiology, Franziskus Hospital, Bielefeld, Germany; 4Department of OB/GYN, Faculty of Medicine, University of Alexandria, Alexandria, EgyptAbstract: The idea of an automated whole breast ultrasound was developed three decades ago. We present our initial experiences with the latest technical advance in this technique, the automated breast volume scanner (ABVS ACUSON S2000TM. Volume data sets were collected from 50 patients and a database containing 23 women with no detectable lesions in conventional ultrasound (BI-RADS®-US 1, 13 women with clearly benign lesions (BI-RADS®-US 2, and 14 women with known breast cancer (BI-RADS®-US 5 was created. An independent examiner evaluated the ABVS data on a separate workstation without any prior knowledge of the patients’ histories. The diagnostic accuracy for the experimental ABVS was 66.0% (95% confidence interval [CI]: 52.9–79.1. The independent examiner detected all breast cancers in the volume data resulting in a calculated sensitivity of 100% in the described setting (95% CI: 73.2%–100%. After the ABVS examination, there were a high number of requests for second-look ultrasounds in 47% (95% CI: 30.9–63.5 of the healthy women (with either a clearly benign lesion or no breast lesions at all in conventional handheld ultrasound. Therefore, the specificity remained at 52.8% (95% CI: 35.7–69.2. When comparing the concordance of the ABVS with the gold standard (conventional handheld ultrasound, Cohen’s Kappa value as an estimation of the inter-rater reliability was κ = 0.37, indicating fair agreement. In conclusion, the ABVS must still be regarded as an experimental technique for breast ultrasound, which

  7. Ultrasound-Guided Percutaneous Catheter Drainage of Large Breast Abscesses in Lactating Women: How to Preserve Breastfeeding Safely.

    Science.gov (United States)

    Falco, Giuseppe; Foroni, Monica; Castagnetti, Fabio; Marano, Luigi; Bordoni, Daniele; Rocco, Nicola; Marchesi, Vanessa; Iotti, Valentina; Vacondio, Rita; Ferrari, Guglielmo

    2016-12-01

    Management of breast abscess in lactating women remains controversial. During pregnancy, women may develop different kinds of benign breast lesions that could require a surgical incision performed under general anesthesia with consequent breastfeeding interruption. The purpose of this study was to prospectively evaluate the management of large breast abscesses with ultrasound-assisted drainage aiming at breastfeeding preservation. 34 lactating women with a diagnosis of unilateral breast abscess have been treated with an ultrasound (US)-assisted drainage of the abscess. A pigtail catheter was inserted into the fluid collection using the Seldinger technique under US guide and connected to a three stop way to allow drainage and irrigation of the cavity until its resolution. All procedures have been found safe and well tolerated. No recurrence was observed and breastfeeding was never interrupted. The described technique allows to avoid surgery and to preserve breastfeeding in well-selected patients with a safe, well-tolerated and cost-effective procedure.

  8. Processed images in human perception: A case study in ultrasound breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yap, Moi Hoon [Department of Computer Science, Loughborough University, FH09, Ergonomics and Safety Research Institute, Holywell Park (United Kingdom)], E-mail: M.H.Yap@lboro.ac.uk; Edirisinghe, Eran [Department of Computer Science, Loughborough University, FJ.05, Garendon Wing, Holywell Park, Loughborough LE11 3TU (United Kingdom); Bez, Helmut [Department of Computer Science, Loughborough University, Room N.2.26, Haslegrave Building, Loughborough University, Loughborough LE11 3TU (United Kingdom)

    2010-03-15

    Two main research efforts in early detection of breast cancer include the development of software tools to assist radiologists in identifying abnormalities and the development of training tools to enhance their skills. Medical image analysis systems, widely known as Computer-Aided Diagnosis (CADx) systems, play an important role in this respect. Often it is important to determine whether there is a benefit in including computer-processed images in the development of such software tools. In this paper, we investigate the effects of computer-processed images in improving human performance in ultrasound breast cancer detection (a perceptual task) and classification (a cognitive task). A survey was conducted on a group of expert radiologists and a group of non-radiologists. In our experiments, random test images from a large database of ultrasound images were presented to subjects. In order to gather appropriate formal feedback, questionnaires were prepared to comment on random selections of original images only, and on image pairs consisting of original images displayed alongside computer-processed images. We critically compare and contrast the performance of the two groups according to perceptual and cognitive tasks. From a Receiver Operating Curve (ROC) analysis, we conclude that the provision of computer-processed images alongside the original ultrasound images, significantly improve the perceptual tasks of non-radiologists but only marginal improvements are shown in the perceptual and cognitive tasks of the group of expert radiologists.

  9. Processed images in human perception: A case study in ultrasound breast imaging

    International Nuclear Information System (INIS)

    Yap, Moi Hoon; Edirisinghe, Eran; Bez, Helmut

    2010-01-01

    Two main research efforts in early detection of breast cancer include the development of software tools to assist radiologists in identifying abnormalities and the development of training tools to enhance their skills. Medical image analysis systems, widely known as Computer-Aided Diagnosis (CADx) systems, play an important role in this respect. Often it is important to determine whether there is a benefit in including computer-processed images in the development of such software tools. In this paper, we investigate the effects of computer-processed images in improving human performance in ultrasound breast cancer detection (a perceptual task) and classification (a cognitive task). A survey was conducted on a group of expert radiologists and a group of non-radiologists. In our experiments, random test images from a large database of ultrasound images were presented to subjects. In order to gather appropriate formal feedback, questionnaires were prepared to comment on random selections of original images only, and on image pairs consisting of original images displayed alongside computer-processed images. We critically compare and contrast the performance of the two groups according to perceptual and cognitive tasks. From a Receiver Operating Curve (ROC) analysis, we conclude that the provision of computer-processed images alongside the original ultrasound images, significantly improve the perceptual tasks of non-radiologists but only marginal improvements are shown in the perceptual and cognitive tasks of the group of expert radiologists.

  10. Determinants of DHA levels in early infancy: differential effects of breast milk and direct fish oil supplementation.

    Science.gov (United States)

    Meldrum, S J; D'Vaz, N; Casadio, Y; Dunstan, J A; Niels Krogsgaard-Larsen, N; Simmer, K; Prescott, S L

    2012-06-01

    Although omega (n)-3 long-chain polyunsaturated fatty acids (LCPUFA), particularly docosahexaenoic acid (DHA), intakes are important during infancy, the optimal method of increasing infant status remains unclear. We hypothesized that high-dose infant fish oil supplementation would have greater relative effects upon n-3 LCPUFA status at six months of age than breast milk fatty acids. Infants (n=420) were supplemented daily from birth to six months with fish oil or placebo. In a subset of infants, LCPUFA levels were measured in cord blood, breast milk and in infant blood at 6 months. DHA levels increased in the fish oil group relative to placebo (p<05). Breast milk DHA was the strongest predictor of infant erythrocyte DHA levels (p=<001). This remained significant after adjustment for cord blood DHA, supplementation group and adherence. In this cohort, breast milk DHA was a greater determinant of infant erythrocyte n-3 LCPUFA status, than direct supplementation with fish oil. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Does shear wave ultrasound independently predict axillary lymph node metastasis in women with invasive breast cancer?

    OpenAIRE

    Evans, Andrew; Rauchhaus, Petra; Whelehan, Patsy; Thomson, Kim; Purdie, Colin A.; Jordan, Lee B.; Michie, Caroline O.; Thompson, Alastair; Vinnicombe, Sarah

    2013-01-01

    Shear wave elastography (SWE) shows promise as an adjunct to greyscale ultrasound examination in assessing breast masses. In breast cancer, higher lesion stiffness on SWE has been shown to be associated with features of poor prognosis. The purpose of this study was to assess whether lesion stiffness at SWE is an independent predictor of lymph node involvement. Patients with invasive breast cancer treated by primary surgery, who had undergone SWE examination were eligible. Data were retrospect...

  12. Digital Breast Tomosynthesis versus Supplemental Diagnostic Mammographic Views for Evaluation of Noncalcified Breast Lesions

    Science.gov (United States)

    Bandos, Andriy I.; Ganott, Marie A.; Sumkin, Jules H.; Kelly, Amy E.; Catullo, Victor J.; Rathfon, Grace Y.; Lu, Amy H.; Gur, David

    2013-01-01

    Purpose: To compare the diagnostic performance of breast tomosynthesis versus supplemental mammography views in classification of masses, distortions, and asymmetries. Materials and Methods: Eight radiologists who specialized in breast imaging retrospectively reviewed 217 consecutively accrued lesions by using protocols that were HIPAA compliant and institutional review board approved in 182 patients aged 31–60 years (mean, 50 years) who underwent diagnostic mammography and tomosynthesis. The lesions in the cohort included 33% (72 of 217) cancers and 67% (145 of 217) benign lesions. Eighty-four percent (182 of 217) of the lesions were masses, 11% (25 of 217) were asymmetries, and 5% (10 of 217) were distortions that were initially detected at clinical examination in 8% (17 of 217), at mammography in 80% (173 of 217), at ultrasonography (US) in 11% (25 of 217), or at magnetic resonance imaging in 1% (2 of 217). Histopathologic examination established truth in 191 lesions, US revealed a cyst in 12 lesions, and 14 lesions had a normal follow-up. Each lesion was interpreted once with tomosynthesis and once with supplemental mammographic views; both modes included the mediolateral oblique and craniocaudal views in a fully crossed and balanced design by using a five-category Breast Imaging Reporting and Data System (BI-RADS) assessment and a probability-of-malignancy score. Differences between modes were analyzed with a generalized linear mixed model for BI-RADS–based sensitivity and specificity and with modified Obuchowski-Rockette approach for probability-of-malignancy–based area under the receiver operating characteristic (ROC) curve. Results: Average probability-of-malignancy–based area under the ROC curve was 0.87 for tomosynthesis versus 0.83 for supplemental views (P tomosynthesis, the false-positive rate decreased from 85% (989 of 1160) to 74% (864 of 1160) (P tomosynthesis, more cancers were classified as BI-RADS category 5 (39% [226 of 576] vs 33% [188

  13. Role of magnetic resonance imaging in breast cancer management

    Directory of Open Access Journals (Sweden)

    Selvi Radhakrishna

    2018-01-01

    Full Text Available Magnetic resonance imaging (MRI of the breast is primarily used as a supplemental tool to breast screening with mammography or ultrasound. A breast MRI is mainly used for women who have been diagnosed with breast cancer, to help measure the size of the cancer, look for other tumors in the breast, and to check for tumors in the opposite breast. For certain women at high risk for breast cancer, a screening MRI is recommended along with a yearly mammogram. MRI is known to give some false positive results which mean more test and/or biopsies for the patient. Thus, although breast MRI is useful for women at high risk, it is rarely recommended as a screening test for women at average risk of breast cancer. Also, breast MRI does not show calcium deposits, known as micro-calcifications which can be a sign of breast cancer.

  14. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    OpenAIRE

    Kang, Yun-Dan; Kim, You Me

    2015-01-01

    Purpose: The purpose of this study was to compare needle aspiration and vacuum-assistedbiopsy in the ultrasound-guided treatment of lactational breast abscesses. Methods: Between January 2005 and December 2014, a total of 74 patients presented withlactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated withneedle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration ...

  15. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  16. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  17. Computer-Aided Diagnosis for Breast Ultrasound Using Computerized BI-RADS Features and Machine Learning Methods.

    Science.gov (United States)

    Shan, Juan; Alam, S Kaisar; Garra, Brian; Zhang, Yingtao; Ahmed, Tahira

    2016-04-01

    This work identifies effective computable features from the Breast Imaging Reporting and Data System (BI-RADS), to develop a computer-aided diagnosis (CAD) system for breast ultrasound. Computerized features corresponding to ultrasound BI-RADs categories were designed and tested using a database of 283 pathology-proven benign and malignant lesions. Features were selected based on classification performance using a "bottom-up" approach for different machine learning methods, including decision tree, artificial neural network, random forest and support vector machine. Using 10-fold cross-validation on the database of 283 cases, the highest area under the receiver operating characteristic (ROC) curve (AUC) was 0.84 from a support vector machine with 77.7% overall accuracy; the highest overall accuracy, 78.5%, was from a random forest with the AUC 0.83. Lesion margin and orientation were optimum features common to all of the different machine learning methods. These features can be used in CAD systems to help distinguish benign from worrisome lesions. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. All rights reserved.

  18. Update on Breast Cancer Detection Using Comb-Push Ultrasound Shear Elastography.

    Science.gov (United States)

    Denis, Max; Bayat, Mahdi; Mehrmohammadi, Mohammad; Gregory, Adriana; Song, Pengfei; Whaley, Dana H; Pruthi, Sandhya; Chen, Shigao; Fatemi, Mostafa; Alizad, Azra

    2015-09-01

    In this work, tissue stiffness estimates are used to differentiate between benign and malignant breast masses in a group of pre-biopsy patients. The rationale is that breast masses are often stiffer than healthy tissue; furthermore, malignant masses are stiffer than benign masses. The comb-push ultrasound shear elastography (CUSE) method is used to noninvasively assess a tissue's mechanical properties. CUSE utilizes a sequence of simultaneous multiple laterally spaced acoustic radiation force (ARF) excitations and detection to reconstruct the region of interest (ROI) shear wave speed map, from which a tissue stiffness property can be quantified. In this study, the tissue stiffnesses of 73 breast masses were interrogated. The mean shear wave speeds for benign masses (3.42 ± 1.32 m/s) were lower than malignant breast masses (6.04 ± 1.25 m/s). These speed values correspond to higher stiffness in malignant breast masses (114.9 ± 40.6 kPa) than benign masses (39.4 ± 28.1 kPa and p 83 kPa is established as a cut-off value for differentiating between malignant and benign suspicious breast masses, with a receiver operating characteristic curve (ROC) of 89.19% sensitivity, 88.69% specificity, and 0.911 for the area under the curve (AUC).

  19. Mammography in breast screening and in the evaluation and management of breast cancer

    International Nuclear Information System (INIS)

    Onyesoh, C.N.

    2006-01-01

    This paper aims to discuss the importance of breast screening most especially amongst women above the age of 40 years.the limitation of the screening procedure is due to lack of special machines and power awareness campaigns. the application of Mammography and ultrasound in the examination of the breast and other breast imaging techniques will be considered in this paper. The paper will look at the indications for mammography, indications for breast ultrasound, signs of breast carcinoma on mammography, breast enlargement and also the need for breast ultrasound in cases of discrete Mammography

  20. Does the insertion of a gel-based marker at stereotactic breast biopsy allow subsequent wire localizations to be carried out under ultrasound guidance?

    International Nuclear Information System (INIS)

    McMahon, M.A.; James, J.J.; Cornford, E.J.; Hamilton, L.J.; Burrell, H.C.

    2011-01-01

    Aim: To investigate whether the insertion of a gel-based marker at the time of stereotactic breast biopsy allows subsequent preoperative localization to be performed under ultrasound guidance. Materials and methods: One hundred consecutive women who underwent either a 10 G stereotactic vacuum-assisted breast biopsy or 14 G stereotactic core biopsy with marker placement, followed by wire localization and surgical excision were identified. All had mammographic abnormalities not initially visible with ultrasound. The method of preoperative localization was recorded and its success judged with reference to the wire position on the post-procedure films relative to the mammographic abnormality and the marker. Histopathology data were reviewed to ensure the lesion had been adequately excised. Results: Eighty-three women (83%) had a successful ultrasound-guided wire localization. Successful ultrasound-guided localization was more likely after stereotactic vacuum biopsy (86%) compared to stereotactic core biopsy (68%), although this did not quite reach statistical significance (p = 0.06). Conclusion: The routine placement of a gel-based marker after stereotactic breast biopsy facilitates preoperative ultrasound-guided localization.

  1. Breast ultrasound image segmentation: an optimization approach based on super-pixels and high-level descriptors

    Science.gov (United States)

    Massich, Joan; Lemaître, Guillaume; Martí, Joan; Mériaudeau, Fabrice

    2015-04-01

    Breast cancer is the second most common cancer and the leading cause of cancer death among women. Medical imaging has become an indispensable tool for its diagnosis and follow up. During the last decade, the medical community has promoted to incorporate Ultra-Sound (US) screening as part of the standard routine. The main reason for using US imaging is its capability to differentiate benign from malignant masses, when compared to other imaging techniques. The increasing usage of US imaging encourages the development of Computer Aided Diagnosis (CAD) systems applied to Breast Ultra-Sound (BUS) images. However accurate delineations of the lesions and structures of the breast are essential for CAD systems in order to extract information needed to perform diagnosis. This article proposes a highly modular and flexible framework for segmenting lesions and tissues present in BUS images. The proposal takes advantage of optimization strategies using super-pixels and high-level descriptors, which are analogous to the visual cues used by radiologists. Qualitative and quantitative results are provided stating a performance within the range of the state-of-the-art.

  2. 3-D Ultrasound Vascularity Assessment for Breast Cancer Diagnosis

    Science.gov (United States)

    2000-09-01

    Boehm, T., Shing, Y ., Fdkai, N., Vasios, G., Lane, 29. Parke, A., Bhattacherjee, P., Palmer, R. M., and Lazarus , N. R. W. S., Flynn, E., Birkhead, J...P. L. Utility of 3D ultrasound in the R. A., Moses, M., Lane, W. S., Cao, Y ., Sage, E. H., and Folkman , J. discrimination and detection of breast...References/Appendices 7), (Abstracts y (mm) (min/set) 6,7,9,10,18); 5) expanding the field of view 5x5x5 subvols. 0.17 5.3 by combining several partially

  3. Changes in vitamin and mineral supplement use after breast cancer diagnosis in the Pathways Study: a prospective cohort study

    International Nuclear Information System (INIS)

    Greenlee, Heather; Hershman, Dawn L; Neugut, Alfred I; Kushi, Lawrence H; Kwan, Marilyn L; Ergas, Isaac J; Strizich, Garrett; Roh, Janise M; Wilson, Allegra T; Lee, Marion; Sherman, Karen J; Ambrosone, Christine B

    2014-01-01

    Vitamin and mineral supplement use after a breast cancer diagnosis is common and controversial. Dosages used and the timing of initiation and/or discontinuation of supplements have not been clearly described. We prospectively examined changes in use of 17 vitamin/mineral supplements in the first six months following breast cancer diagnosis among 2,596 members (28% non-white) of Kaiser Permanente Northern California. We used multivariable logistic regression to examine demographic, clinical, and lifestyle predictors of initiation and discontinuation. Most women used vitamin/mineral supplements before (84%) and after (82%) diagnosis, with average doses far in excess of Institute of Medicine reference intakes. Over half (60.2%) reported initiating a vitamin/mineral following diagnosis, 46.3% discontinuing a vitamin/mineral, 65.6% using a vitamin/mineral continuously, and only 7.2% not using any vitamin/mineral supplement before or after diagnosis. The most commonly initiated supplements were calcium (38.2%), vitamin D (32.01%), vitamin B6 (12.3%) and magnesium (11.31%); the most commonly discontinued supplements were multivitamins (17.14%), vitamin C (15.97%) and vitamin E (45.62%). Higher education, higher intake of fruits/vegetables, and receipt of chemotherapy were associated with initiation (p-values <0.05). Younger age and breast-conserving surgery were associated with discontinuation (p-values <0.05). In this large cohort of ethnically diverse breast cancer patients, high numbers of women used vitamin/mineral supplements in the 6 months following breast cancer diagnosis, often at high doses and in combination with other supplements. The immediate period after diagnosis is a critical time for clinicians to counsel women on supplement use

  4. Evaluation of diagnosis of small breast cancer with high frequency and color doppler ultrasound

    International Nuclear Information System (INIS)

    Xia Guobing; Hu Chunhong; Jing Qiulong

    2008-01-01

    Objective: To probe the features of high frequency ultrasonography (HFU) and color Doppler ultrasound (CDU) in the case of small breast cancers in order to evaluate the diagnostic value for small breast cancer with CDU. Methods: The features of HFU and CDU were respective analyzed in 67 small breast masses, the biggest diameter of which was under 2cm identified with pathology. Results Partially characteristic changes of small breast cancers were displayed, and micro-calcification within the mass was an important characteristic, in addition, the Resistant Index (RI) ≥ 0.70 on Pulsed Doppler (PD) and the grade of blood flow on Color Doppler Flow Imaging (CDFI)≥T2 implied much more positive malignancy prediction. Conclusion: HFU integrated with CDU can be used for the early and accurate diagnosis of the small breast cancer. (authors)

  5. The impact of breast cancer biological subtyping on tumor size assessment by ultrasound and mammography - a retrospective multicenter cohort study of 6543 primary breast cancer patients

    International Nuclear Information System (INIS)

    Stein, Roland Gregor; Wollschläger, Daniel; Kreienberg, Rolf; Janni, Wolfgang; Wischnewsky, Manfred; Diessner, Joachim; Stüber, Tanja; Bartmann, Catharina; Krockenberger, Mathias; Wischhusen, Jörg; Wöckel, Achim; Blettner, Maria; Schwentner, Lukas

    2016-01-01

    Mammography and ultrasound are the gold standard imaging techniques for preoperative assessment and for monitoring the efficacy of neoadjuvant chemotherapy in breast cancer. Maximum accuracy in predicting pathological tumor size non-invasively is critical for individualized therapy and surgical planning. We therefore aimed to assess the accuracy of tumor size measurement by ultrasound and mammography in a multicentered health services research study. We retrospectively analyzed data from 6543 patients with unifocal, unilateral primary breast cancer. The maximum tumor diameter was measured by ultrasound and/or mammographic imaging. All measurements were compared to final tumor diameter determined by postoperative histopathological examination. We compared the precision of each imaging method across different patient subgroups as well as the method-specific accuracy in each patient subgroup. Overall, the correlation with histology was 0.61 for mammography and 0.60 for ultrasound. Both correlations were higher in pT2 cancers than in pT1 and pT3. Ultrasound as well as mammography revealed a significantly higher correlation with histology in invasive ductal compared to lobular cancers (p < 0.01). For invasive lobular cancers, the mammography showed better correlation with histology than ultrasound (p = 0.01), whereas there was no such advantage for invasive ductal cancers. Ultrasound was significantly superior for HR negative cancers (p < 0.001). HER2/neu positive cancers were also more precisely assessed by ultrasound (p < 0.001). The size of HER2/neu negative cancers could be more accurately predicted by mammography (p < 0.001). This multicentered health services research approach demonstrates that predicting tumor size by mammography and ultrasound provides accurate results. Biological tumor features do, however, affect the diagnostic precision

  6. Digital breast tomosynthesis (DBT) to characterize MRI-detected additional lesions unidentified at targeted ultrasound in newly diagnosed breast cancer patients

    International Nuclear Information System (INIS)

    Mariscotti, Giovanna; Durando, Manuela; Regini, Elisa; Fornari, Alberto; Fonio, Paolo; Gandini, Giovanni; Houssami, Nehmat; Campanino, Pier Paolo; Bussone, Riccardo; Castellano, Isabella; Sapino, Anna

    2015-01-01

    Preoperative breast magnetic resonance (MR) often generates additional suspicious findings needing further investigations. Targeted breast ultrasound (US) is the standard tool to characterize MR additional lesions. The purpose of this study is to evaluate the potential role of digital breast tomosynthesis (DBT) to characterize MR detected additional findings, unidentified at targeted breast US. This prospective study included women who a) had biopsy-proven, newly diagnosed breast cancers detected at conventional 2D mammography and/or US, referred to breast MR for tumour staging; and b) had DBT if additional MR findings were not detected at targeted ('second look') US. In 520 patients, MR identified 164 (in 114 women, 22 %) additional enhancing lesions. Targeted US identified 114/164 (69.5 %) of these, whereas 50/164 (30.5 %) remained unidentified. DBT identified 32/50 of these cases, increasing the overall characterization of MR detected additional findings to 89.0 % (146/164). Using DBT the identified lesions were significantly more likely to be malignant than benign MR-detected additional lesions (p = 0.04). DBT improves the characterization of additional MR findings not identified at targeted breast US in preoperative breast cancer staging. (orig.)

  7. Digital breast tomosynthesis (DBT) to characterize MRI-detected additional lesions unidentified at targeted ultrasound in newly diagnosed breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Mariscotti, Giovanna; Durando, Manuela; Regini, Elisa; Fornari, Alberto; Fonio, Paolo; Gandini, Giovanni [Breast Imaging Service, Radiology - University of Turin, Department of Diagnostic Imaging and Radiotherapy, A.O.U. Citta della Salute e della Scienza, Torino (Italy); Houssami, Nehmat [University of Sydney, Screening and Test Evaluation Program, School of Public Health, Sydney Medical School, Sydney, NSW (Australia); Campanino, Pier Paolo [Ospedale Koelliker, Breast Imaging Service, Torino (Italy); Bussone, Riccardo [A.O.U. Citta della Salute e della Scienza of Turin, SSCVD Breast Surgery. Department of Surgery, Torino (Italy); Castellano, Isabella; Sapino, Anna [University of Turin, Department of Biomedical Sciences and Human Oncology, A.O.U. Citta della Salute e della Scienza, Torino (Italy)

    2015-09-15

    Preoperative breast magnetic resonance (MR) often generates additional suspicious findings needing further investigations. Targeted breast ultrasound (US) is the standard tool to characterize MR additional lesions. The purpose of this study is to evaluate the potential role of digital breast tomosynthesis (DBT) to characterize MR detected additional findings, unidentified at targeted breast US. This prospective study included women who a) had biopsy-proven, newly diagnosed breast cancers detected at conventional 2D mammography and/or US, referred to breast MR for tumour staging; and b) had DBT if additional MR findings were not detected at targeted ('second look') US. In 520 patients, MR identified 164 (in 114 women, 22 %) additional enhancing lesions. Targeted US identified 114/164 (69.5 %) of these, whereas 50/164 (30.5 %) remained unidentified. DBT identified 32/50 of these cases, increasing the overall characterization of MR detected additional findings to 89.0 % (146/164). Using DBT the identified lesions were significantly more likely to be malignant than benign MR-detected additional lesions (p = 0.04). DBT improves the characterization of additional MR findings not identified at targeted breast US in preoperative breast cancer staging. (orig.)

  8. Mammotome biopsy under ultrasound control in the diagnostics and treatment of nodular breast lesions - own experience.

    Science.gov (United States)

    Kibil, Wojciech; Hodorowicz-Zaniewska, Diana; Kulig, Jan

    2012-05-01

    Mammotome biopsy is an effective, minimally invasive, novel technique used in the verification of breast lesions.The aim of the study was to assess the value of ultrasound-guided vacuum-assisted core needle biopsy (mammotome biopsy) in the diagnostics and treatment of nodular breast lesions, considering own data.Material and methods. Analysis comprised 1183 mammotome biopsies under ultrasound control performed in 1177 female patients during the period between 2000 and 2010, at the Regional Clinic for Early Diagnostics and Treatment of Breast Lesions, I Chair and Department of General Surgery, Jagiellonian University, Collegium Medicum.Results. The average patient age amounted to 41.7 years. The size of the investigated lesions ranged between 4 and 65 mm (mean - 12 mm). The histopathological examination result was as follows: fibrocystic lesions (n=285), adenofibroma (n=477), adenosis sclerosans (n=188), hyperplasia without atypy (n=58), phyllode tumor (n=2), papilloma (n=14), hamartoma (n=1), atypical hyperplasia (n=25), in situ ductal carcinoma (n=4), in situ lobular carcinoma (n=5), infiltrating ductal carcinoma (n=114), infiltrating lobular carcinoma (n=4), non-diagnostic result (n=6). The histopathological diagnosis was obtained in 99.5% of cases. Patients diagnosed with atypical hyperplasia or cancer were qualified for surgery, according to accepted standards. The presence of a hematoma was the most common complication after the biopsy, observed in 16.5% of patients.Conclusions. The obtained results confirmed the high value of ultrasound-guided biopsies in the diagnostics of nodular breast lesions. The method is safe, minimally invasive, with few complications, providing a good cosmetic effect. In case of benign lesions with a diameter of less than 15 mm the mammotome biopsy enables to completely excise the lesions, being an alternative to open surgical biopsies. The mammotome biopsy should become the method of choice considering the diagnostics of nodular

  9. Towards real-time 3D ultrasound planning and personalized 3D printing for breast HDR brachytherapy treatment

    International Nuclear Information System (INIS)

    Poulin, Eric; Gardi, Lori; Fenster, Aaron; Pouliot, Jean; Beaulieu, Luc

    2015-01-01

    Two different end-to-end procedures were tested for real-time planning in breast HDR brachytherapy treatment. Both methods are using a 3D ultrasound (3DUS) system and a freehand catheter optimization algorithm. They were found fast and efficient. We demonstrated a proof-of-concept approach for personalized real-time guidance and planning to breast HDR brachytherapy treatments

  10. Response monitoring of breast cancer patients receiving neoadjuvant chemotherapy using quantitative ultrasound, texture, and molecular features.

    Directory of Open Access Journals (Sweden)

    Lakshmanan Sannachi

    Full Text Available Pathological response of breast cancer to chemotherapy is a prognostic indicator for long-term disease free and overall survival. Responses of locally advanced breast cancer in the neoadjuvant chemotherapy (NAC settings are often variable, and the prediction of response is imperfect. The purpose of this study was to detect primary tumor responses early after the start of neoadjuvant chemotherapy using quantitative ultrasound (QUS, textural analysis and molecular features in patients with locally advanced breast cancer.The study included ninety six patients treated with neoadjuvant chemotherapy. Breast tumors were scanned with a clinical ultrasound system prior to chemotherapy treatment, during the first, fourth and eighth week of treatment, and prior to surgery. Quantitative ultrasound parameters and scatterer-based features were calculated from ultrasound radio frequency (RF data within tumor regions of interest. Additionally, texture features were extracted from QUS parametric maps. Prior to therapy, all patients underwent a core needle biopsy and histological subtypes and biomarker ER, PR, and HER2 status were determined. Patients were classified into three treatment response groups based on combination of clinical and pathological analyses: complete responders (CR, partial responders (PR, and non-responders (NR. Response classifications from QUS parameters, receptors status and pathological were compared. Discriminant analysis was performed on extracted parameters using a support vector machine classifier to categorize subjects into CR, PR, and NR groups at all scan times.Of the 96 patients, the number of CR, PR and NR patients were 21, 52, and 23, respectively. The best prediction of treatment response was achieved with the combination mean QUS values, texture and molecular features with accuracies of 78%, 86% and 83% at weeks 1, 4, and 8, after treatment respectively. Mean QUS parameters or clinical receptors status alone predicted the

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... biopsies , in which needles are used to sample cells from an abnormal area for laboratory testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ...

  12. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  13. Strain elastography of abnormal axillary nodes in breast cancer patients does not improve diagnostic accuracy compared with conventional ultrasound alone.

    Science.gov (United States)

    Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse

    2014-12-01

    The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (pultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ... are sometimes the best way to see if treatment is working or if a finding is stable ...

  15. Ultrasound-guided lumpectomy of nonpalpable breast cancer versus wire-guided resection: a randomized clinical trial.

    NARCIS (Netherlands)

    Rahusen, F.D.; Bremers, A.J.A.; Fabry, H.F.; Taets van Amerongen, A.H.; Boom, R.P.; Meijer, S.

    2002-01-01

    BACKGROUND: The wire-guided excision of nonpalpable breast cancer often results in tumor resections with inadequate margins. This prospective, randomized trial was undertaken to investigate whether intraoperative ultrasound (US) guidance enables a better margin clearance than the wire-guided

  16. Accuracy of CESM versus conventional mammography and ultrasound in evaluation of BI-RADS 3 and 4 breast lesions with pathological correlation

    Directory of Open Access Journals (Sweden)

    Maha Helal

    2017-09-01

    Full Text Available Aim: Assess accuracy of contrast enhanced spectral mammography (CESM versus conventional mammography and ultrasound in evaluation of BI-RADS 3 and 4 breast lesions with pathological correlation. Patients and methods: Thirty female patients with 35 breast lesions diagnosed by conventional imaging as BI-RADS 3 and 4, presented to Women’s Imaging Unit of Radiology Department between January and December 2015, age ranged from 23 to 70 years. All patients underwent conventional mammography and ultrasound then CESM. Results: Patients divided into two groups, benign and malignant lesions group according to histological analysis. Mammography results that malignant lesions detected in 18/35 (51.4% while benign lesions 17/35 (48.6%. Ultrasound revealed 27/35 (77.1% lesions were malignant and 8/35 (22.9% lesions benign. But CESM, revealed 25/35 (71.4% lesions were malignant & 10/35 (28.6% lesions benign. Among 7 patients with multifocal/ multi-centric histologically proven malignant lesions, all detected by CESM 7/7 cases (100% versus 2/7 cases (28.6% and 6/7 cases (85.7% detected by mammography and ultrasound respectively. Based on, CESM had 95.2% sensitivity and 82.9% diagnostic accuracy. Conclusion: CESM has better diagnostic accuracy than mammography alone and mammography plus ultrasound. CESM has 82.9% diagnostic accuracy in comparison to 51.4% for mammography and 77.1% for ultrasound. Keywords: Breast lesions, CESM, BI-RADS lexicon

  17. TU-F-12A-09: GLCM Texture Analysis for Normal-Tissue Toxicity: A Prospective Ultrasound Study of Acute Toxicity in Breast-Cancer Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, T; Yang, X; Curran, W; Torres, M [Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA (United States)

    2014-06-15

    Purpose: To evaluate the morphologic and structural integrity of the breast glands using sonographic textural analysis, and identify potential early imaging signatures for radiation toxicity following breast-cancer radiotherapy (RT). Methods: Thirty-eight patients receiving breast RT participated in a prospective ultrasound imaging study. Each participant received 3 ultrasound scans: 1 week before RT (baseline), and at 6-week and 3-month follow-ups. Patients were imaged with a 10-MHz ultrasound on the four quadrant of the breast. A second order statistical method of texture analysis, called gray level co-occurrence matrix (GLCM), was employed to assess RT-induced breast-tissue toxicity. The region of interest (ROI) was 28 mm × 10 mm in size at a 10 mm depth under the skin. Twenty GLCM sonographic features, ratios of the irradiated breast and the contralateral breast, were used to quantify breast-tissue toxicity. Clinical assessment of acute toxicity was conducted using the RTOG toxicity scheme. Results: Ninety-seven ultrasound studies (776 images) were analyzed; and 5 out of 20 sonographic features showed significant differences (p < 0.05) among the baseline scans, the acute toxicity grade 1 and 2 groups. These sonographic features quantified the degree of tissue damage through homogeneity, heterogeneity, randomness, and symmetry. Energy ratio value decreased from 108±0.05 (normal) to 0.99±0.05 (Grade 1) and 0.84±0.04 (Grade 2); Entropy ratio value increased from 1.01±0.01 to 1.02±0.01 and 1.04±0.01; Contrast ratio value increased from 1.03±0.03 to 1.07±0.06 and 1.21±0.09; Variance ratio value increased from 1.06±0.03 to 1.20±0.04 and 1.42±0.10; Cluster Prominence ratio value increased from 0.98±0.02 to 1.01±0.04 and 1.25±0.07. Conclusion: This work has demonstrated that the sonographic features may serve as imaging signatures to assess radiation-induced normal tissue damage. While these findings need to be validated in a larger cohort, they suggest

  18. Histopathology of breast cancer after magnetic resonance-guided high-intensity focused ultrasound and radiofrequency ablation

    NARCIS (Netherlands)

    Knuttel, Floor; Waaijer, Laurien; Merckel, LG; van den Bosch, Maurice A A J; Witkamp, Arjen J.; Deckers, Roel; van Diest, Paul J.

    AIMS: Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation and radiofrequency ablation (RFA) are being researched as possible substitutes for surgery in breast cancer patients. The histopathological appearance of ablated tissue has not been studied in great detail. This

  19. Aspiration of breast abscess under ultrasound guidance: outcome obtained and factors affecting success.

    Science.gov (United States)

    Elagili, Faisal; Abdullah, Norlia; Fong, Liew; Pei, Tan

    2007-01-01

    To assess ultrasonographically (US) guided needle aspiration of breast abscesses as an alternative to surgical incision and drainage. In our prospective study, 30 patients with 31 breast abscesses (one patient had bilateral breast abscess) underwent percutaneous breast abscess drainage under US guidance with local anaesthesia and oral antibiotics between 1 January 2004 and 31 March 2005. These patients consisted of 16 (53.3%) non-lactating and 14 (46.7%) lactating women, with ages ranging from 18 to 68 years (median, 28 years). The racial distribution comprised 26 (86.7%) Malays, three (10%) Chinese and one (3.3%) Indian. All patients had the chief complaint of breast swelling and 25 (83.3%) had breast pain. Clinically, 28 (93.3%) were found to have a palpable mass. Nine (30%) lesions were in the upper outer quadrant of the left breast. US diameters ranged from 1 to 15 cm (median, 4 cm). The pus volumes varied from 1 to 200 mL (median, 14 mL). Fifteen (50%) patients required only a single aspiration, 10 required multiple aspirations and five required incision and drainage. Those patients in whom needle aspiration failed had multiloculated lesions irrespective of abscess volume and size. Needle aspiration with ultrasound guidance is an effective treatment for breast abscess irrespective of abscess volume and size.

  20. Breast cancer screening: Evidence of the effect of adjunct ultrasound screening in women with unilateral mammography-negative dense breasts

    Directory of Open Access Journals (Sweden)

    Atoosa Adibi

    2015-01-01

    Full Text Available Background: Patients with the previous history of breast cancer are in risk of contralateral breast cancer. On the other hand, increased breast density is a risk factor for breast cancer and the sensitivity of detecting nonpalpable cancers in screening mammography in radiographically dense breasts is low. The use of ultrasonography in dense breast remains a controversial topic. The purpose of this study was to assess the usefulness of routine ultrasonography in follow-up of women with the previous history of breast cancer and negative mammography but dense breasts. Materials and Methods: In a cross-sectional study, a total of 267 individuals with unilateral postmastectomy mammogram screened and 153 subjects assigned to study. There were 28 subjects with American College of Radiology (ACR breast density 2 and 125 with ACR breast density 3-4, which there was no new finding in their mammogram in comparison to previous studies. We assumed subjects with ACR breast density 3-4 as mammographic Breast Imaging Reporting and Data System (BI-RADS category 0 for malignancy. Standard two-view mammogram was performed for all participants, and breast ultrasound (US examinations were performed by an expert radiologist in radial and anti-radial planes. The data were analyzed using SPSS version 20.0 (SPSS Inc., Chicago, Illinois, USA. Results: The results showed that in subjects with ACR breast density 3-4, when there was no new density in two consecutive mammograms in comparison to previous studies, US also showed no possibility for malignancy (BI-RADS 1-2. And also in subjects with ACR breast density 2, when the mammographic results were BI-RADS 1-2, the US results was the same. Conclusion: Our data indicate that for the detection of breast cancer, sensitivity of US was not greater than mammography in patients with postmastectomy unilateral dense breast if there is not any new density.

  1. Comparison of naïve Bayes and logistic regression for computer-aided diagnosis of breast masses using ultrasound imaging

    Science.gov (United States)

    Cary, Theodore W.; Cwanger, Alyssa; Venkatesh, Santosh S.; Conant, Emily F.; Sehgal, Chandra M.

    2012-03-01

    This study compares the performance of two proven but very different machine learners, Naïve Bayes and logistic regression, for differentiating malignant and benign breast masses using ultrasound imaging. Ultrasound images of 266 masses were analyzed quantitatively for shape, echogenicity, margin characteristics, and texture features. These features along with patient age, race, and mammographic BI-RADS category were used to train Naïve Bayes and logistic regression classifiers to diagnose lesions as malignant or benign. ROC analysis was performed using all of the features and using only a subset that maximized information gain. Performance was determined by the area under the ROC curve, Az, obtained from leave-one-out cross validation. Naïve Bayes showed significant variation (Az 0.733 +/- 0.035 to 0.840 +/- 0.029, P machine learning models for characterizing solid breast masses on ultrasound.

  2. Differential diagnosis of breast lesions using ultrasound elastography

    Directory of Open Access Journals (Sweden)

    Ioana Andreea Gheonea

    2011-01-01

    Full Text Available Context: The recent introduction of elastography has increased the specificity of USG and enabled early diagnosis of breast cancer. Quantitative elastography, especially with strain ratio (SR index, improves diagnostic accuracy and decreased number of biopsies. Aims: The purpose of this study was to assess the role of USG elastography in the differential diagnosis of breast lesions. Settings and Design: This prospective study was conducted in the University of Medicine and Pharmacy Research Centre of Craiova. Materials and Methods: Fifty-eight patients diagnosed with breast lesions between January 2009 and January 2010 were included in this prospective study. All the patients were examined in the supine position, and the B-mode USG image was displayed alongside the elastography strain image. For obtaining the elastography images we used a EUS Hitachi EUB 8500 ultrasound system with a 6.5-MHz linear probe. The elastography strain images were scored according to the Tsukuba elasticity score. Statistical Analysis: We performed receiver operator characteristic (ROC analysis for assessment of the role of USG elastography in the diagnosis of breast lesions. Results: We obtained a sensitivity of 86.7% and a specificity of 92.9% for elasticity score and a sensitivity of 93.3% and a specificity of 92.9% for SR (when a cutoff point of 3.67 was used. There was very good correlation between SR and elasticity score (Spearman coefficient of 0.911. Conclusions: Elastography is a fast, simple method that can complement conventional USG examination. This method has the lowest cost/efficiency ratio and it is also the most noninvasive and accessible imaging method, with an accuracy comparable to MRI.

  3. What are the characteristics of breast cancers misclassified as benign by quantitative ultrasound shear wave elastography?

    Science.gov (United States)

    Vinnicombe, S J; Whelehan, P; Thomson, K; McLean, D; Purdie, C A; Jordan, L B; Hubbard, S; Evans, A J

    2014-04-01

    Shear wave elastography (SWE) is a promising adjunct to greyscale ultrasound in differentiating benign from malignant breast masses. The purpose of this study was to characterise breast cancers which are not stiff on quantitative SWE, to elucidate potential sources of error in clinical application of SWE to evaluation of breast masses. Three hundred and two consecutive patients examined by SWE who underwent immediate surgery for breast cancer were included. Characteristics of 280 lesions with suspicious SWE values (mean stiffness >50 kPa) were compared with 22 lesions with benign SWE values (masses were more often soft on SWE than masses representing invasive breast cancer. Invasive cancers that were soft were more frequently: histological grade 1, tubular subtype, ≤10 mm invasive size and detected at screening mammography. No significant differences were found with respect to the presence of invasive lobular cancer, vascular invasion, hormone and HER-2 receptor status. Lymph node positivity was less common in soft cancers. Malignant breast masses classified as benign by quantitative SWE tend to have better prognostic features than those correctly classified as malignant. • Over 90 % of cancers assessable with ultrasound have a mean stiffness >50 kPa. • 'Soft' invasive cancers are frequently small (≤10 mm), low grade and screen-detected. • Pure DCIS masses are more often soft than invasive cancers (>40 %). • Large symptomatic masses are better evaluated with SWE than small clinically occult lesions. • When assessing small lesions, 'softness' should not raise the threshold for biopsy.

  4. High-intensity focused ultrasound in the treatment of breast tumours.

    Science.gov (United States)

    Peek, Mirjam C L; Wu, Feng

    2018-01-01

    High-intensity focused ultrasound (HIFU) is a minimally invasive technique that has been used for the treatment of both benign and malignant tumours. With HIFU, an ultrasound (US) beam propagates through soft tissue as a high-frequency pressure wave. The US beam is focused at a small target volume, and due to the energy building up at this site, the temperature rises, causing coagulative necrosis and protein denaturation within a few seconds. HIFU is capable of providing a completely non-invasive treatment without causing damage to the directly adjacent tissues. HIFU can be either guided by US or magnetic resonance imaging (MRI). Guided imaging is used to plan the treatment, detect any movement during the treatment and monitor response in real-time. This review describes the history of HIFU, the HIFU technique, available devices and gives an overview of the published literature in the treatment of benign and malignant breast tumours with HIFU.

  5. Xanthophyll and hydrocarbon carotenoid patterns differ in plasma and breast milk of women supplemented with red palm oil during pregnancy and lactation.

    Science.gov (United States)

    Lietz, Georg; Mulokozi, Generose; Henry, Jeya C K; Tomkins, Andrew M

    2006-07-01

    Currently limited information exists on how maternal supplementation with provitamin A carotenoids might influence the carotenoid pattern in breast milk during lactation. This study was designed to investigate the effect of maternal red palm oil supplementation ( approximately 12 g/d) throughout the 3rd trimester of pregnancy and the first 3 mo postpartum on carotenoid pattern in both plasma and breast milk. Plasma and breast milk alpha- and beta-carotene concentrations increased in response to red palm oil supplementation and were different (P lutein and zeaxanthin concentrations were reduced (P milk lutein concentrations, expressed per gram of milk fat, increased (P milk, whereas xanthophylls, such as lutein and zeaxanthin, are proportionally more prevalent in breast milk. More importantly, red palm oil supplementation increases the milk concentrations of provitamin A carotenes without decreasing the milk concentrations of xanthophylls. In summary, this study demonstrates that a regulated uptake of polar carotenoids into breast milk exists and that supplementation with alpha- and beta-carotene does not negatively affect this transfer. The mechanisms behind this transport are not fully understood and merit further study.

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... procedure? Ultrasound examinations can help to diagnose a variety of conditions and to assess organ damage following ... the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart conditions, including valve problems and congestive ...

  7. Lutein supplementation increases breast milk and plasma lutein concentrations in lactating women and infant plasma concentrations but does not affect other carotenoids.

    Science.gov (United States)

    Sherry, Christina L; Oliver, Jeffery S; Renzi, Lisa M; Marriage, Barbara J

    2014-08-01

    Lutein is a carotenoid that varies in breast milk depending on maternal intake. Data are lacking with regard to the effect of dietary lutein supplementation on breast milk lutein concentration during lactation and subsequent plasma lutein concentration in breast-fed infants. This study was conducted to determine the impact of lutein supplementation in the breast milk and plasma of lactating women and in the plasma of breast-fed infants 2-3 mo postpartum. Lutein is the dominant carotenoid in the infant brain and the major carotenoid found in the retina of the eye. Eighty-nine lactating women 4-6 wk postpartum were randomly assigned to be administered either 0 mg/d of lutein (placebo), 6 mg/d of lutein (low-dose), or 12 mg/d of lutein (high-dose). The supplements were consumed for 6 wk while mothers followed their usual diets. Breast milk carotenoids were measured weekly by HPLC, and maternal plasma carotenoid concentrations were measured at the beginning and end of the study. Infant plasma carotenoid concentrations were assessed at the end of the study. No significant differences were found between dietary lutein + zeaxanthin intake and carotenoid concentrations in breast milk and plasma or body mass index at baseline. Total lutein + zeaxanthin concentrations were greater in the low- and high-dose-supplemented groups than in the placebo group in breast milk (140% and 250%, respectively; P Lutein supplementation did not affect other carotenoids in lactating women or their infants. Lactating women are highly responsive to lutein supplementation, which affects plasma lutein concentrations in the infant. This trial was registered at clinicaltrials.gov as NCT01747668. © 2014 American Society for Nutrition.

  8. Ultrasound Guided Intercostobrachial Nerve Blockade in Patients with Persistent Pain after Breast Cancer Surgery

    DEFF Research Database (Denmark)

    Wijayasinghe, Nelun; Duriaud, Helle M; Kehlet, Henrik

    2016-01-01

    BACKGROUND: Persistent pain after breast cancer surgery (PPBCS) affects 25 - 60% of breast cancer survivors and damage to the intercostobrachial nerve (ICBN) has been implicated as the cause of this predominantly neuropathic pain. Local anesthetic blockade of the ICBN could provide clues...... determined the sonoanatomy of the ICBN and part 2 examined effects of the ultrasound-guided ICBN blockade in patients with PPBCS. SETTING: Section for Surgical Pathophysiology at Rigshospitalet, Copenhagen, Denmark. METHODS: Part 1: Sixteen unoperated, pain free breast cancer patients underwent systematic...... to pathophysiological mechanisms as well as aiding diagnosis and treatment of PPBCS but has never been attempted. OBJECTIVES: To assess the feasibility of ICBN blockade and assess its effects on pain and sensory function in patients with PPBCS. STUDY DESIGN: This prospective pilot study was performed in 2 parts: Part 1...

  9. [Vitamin D deficiency among women diagnosed with breast cancer and unclear benefits of vitamin supplementation].

    Science.gov (United States)

    Bednarek, Anna; Chudek, Jerzy; Karwasiecka, Dobromiła; Kubeczko, Marcin; Wojnar, Jerzy

    2015-01-01

    Breast cancer is the most common cancer in the world and also in Poland. Morbidity for breast cancer is increasing, but mortality rate is still on the same level. In Poland morbidity has increased almost two times during the last 30 years. Vitamin D deficiency in the general population is a common phenomenon, especially among obese and elder. It increases the risk of development and worsens the prognosis in breast cancer. In recent years, the role of vitamin D and its nuclear receptor (VDR) in cancer epidemiology, and its impact on the regulation of immune processes have raised interest. VDR acts as ligand-activated transcription factor. Recent studies suggest a role of vitamin D in the regulation of energy pathways in tumor cells. Another observation on vitamin D is its inhibitory effect on inflammation and regulation of glucose metabolism in neoplastic cell. This article explores the available literature on the effect of vitamin D supplementation in women with breast cancer, describes the potential regulatory vitamin D depend mechanisms occurring in the breast cancer. Due to the limited data on the efficacy and safety, the optimal dose of vitamin D in supplementation of patients with cancer breast has not been determined.

  10. Going beyond a First Reader: A Machine Learning Methodology for Optimizing Cost and Performance in Breast Ultrasound Diagnosis.

    Science.gov (United States)

    Venkatesh, Santosh S; Levenback, Benjamin J; Sultan, Laith R; Bouzghar, Ghizlane; Sehgal, Chandra M

    2015-12-01

    The goal of this study was to devise a machine learning methodology as a viable low-cost alternative to a second reader to help augment physicians' interpretations of breast ultrasound images in differentiating benign and malignant masses. Two independent feature sets consisting of visual features based on a radiologist's interpretation of images and computer-extracted features when used as first and second readers and combined by adaptive boosting (AdaBoost) and a pruning classifier resulted in a very high level of diagnostic performance (area under the receiver operating characteristic curve = 0.98) at a cost of pruning a fraction (20%) of the cases for further evaluation by independent methods. AdaBoost also improved the diagnostic performance of the individual human observers and increased the agreement between their analyses. Pairing AdaBoost with selective pruning is a principled methodology for achieving high diagnostic performance without the added cost of an additional reader for differentiating solid breast masses by ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  11. Comparison of conventional and automated breast volume ultrasound in the description and characterization of solid breast masses based on BI-RADS features.

    Science.gov (United States)

    Kim, Hyunji; Cha, Joo Hee; Oh, Ha-Yeun; Kim, Hak Hee; Shin, Hee Jung; Chae, Eun Young

    2014-07-01

    To compare the performance of radiologists in the use of conventional ultrasound (US) and automated breast volume ultrasound (ABVU) for the characterization of benign and malignant solid breast masses based on breast imaging and reporting data system (BI-RADS) criteria. Conventional US and ABVU images were obtained in 87 patients with 106 solid breast masses (52 cancers, 54 benign lesions). Three experienced radiologists who were blinded to all examination results independently characterized the lesions and reported a BI-RADS assessment category and a level of suspicion of malignancy. The results were analyzed by calculation of Cohen's κ coefficient and by receiver operating characteristic (ROC) analysis. Assessment of the agreement of conventional US and ABVU indicated that the posterior echo feature was the most discordant feature of seven features (κ = 0.371 ± 0.225) and that orientation had the greatest agreement (κ = 0.608 ± 0.210). The final assessment showed substantial agreement (κ = 0.773 ± 0.104). The areas under the ROC curves (Az) for conventional US and ABVU were not statistically significant for each reader, but the mean Az values of conventional US and ABVU by multi-reader multi-case analysis were significantly different (conventional US 0.991, ABVU 0.963; 95 % CI -0.0471 to -0.0097). The means for sensitivity, specificity, positive predictive value, and negative predictive value of conventional US and ABVU did not differ significantly. There was substantial inter-observer agreement in the final assessment of solid breast masses by conventional US and ABVU. ROC analysis comparing the performance of conventional US and ABVU indicated a marginally significant difference in mean Az, but not in mean sensitivity, specificity, positive predictive value, or negative predictive value.

  12. Combined Use of Ultrasound Elastography and B-Mode Sonography for Differentiation of Benign and Malignant Circumscribed Breast Masses.

    Science.gov (United States)

    Kim, Soo-Yeon; Park, Jeong Seon; Koo, Hye Ryoung

    2015-11-01

    To evaluate the diagnostic performance of combined B-mode sonography and ultrasound elastography for differentiation between benign and malignant breast masses with circumscribed margins. We analyzed 109 pathologically proven circumscribed breast masses. Two radiologists retrospectively reviewed B-mode sonograms and elastograms in consensus. Based on the American College of Radiology Breast Imaging Reporting and Data System, we determined categories of the masses on B-mode sonography. Elastographic scores were assessed by a 3-point scale (negative, 0; equivocal, 1; and positive, 2). When the elastographic score for a lesion was 0 or 2, we downgraded or upgraded the B-mode category, respectively; thus, the reclassified Breast Imaging Reporting and Data System category was defined as the "reclassification category." Mean category values for benign and malignant lesions were compared by a Student t test. The diagnostic performance of B-mode, elastographic, and reclassification assessments was compared by receiver operating characteristic curve analysis. The mean B-mode category (2.5 versus 1.7), elastographic score (1.7 versus 0.8), and reclassification category (3.2 versus 1.6) were significantly higher in malignant than benign lesions (P benign and malignant circumscribed breast masses, combined use of B-mode sonography and elastography could provide a better diagnostic performance than B-mode sonography alone. © 2015 by the American Institute of Ultrasound in Medicine.

  13. Ultrasound imaging-guided intracardiac injection to develop a mouse model of breast cancer brain metastases followed by longitudinal MRI.

    Science.gov (United States)

    Zhou, Heling; Zhao, Dawen

    2014-03-06

    Breast cancer brain metastasis, occurring in 30% of breast cancer patients at stage IV, is associated with high mortality. The median survival is only 6 months. It is critical to have suitable animal models to mimic the hemodynamic spread of the metastatic cells in the clinical scenario. Here, we are introducing the use of small animal ultrasound imaging to guide an accurate injection of brain tropical breast cancer cells into the left ventricle of athymic nude mice. Longitudinal MRI is used to assessing intracranial initiation and growth of brain metastases. Ultrasound-guided intracardiac injection ensures not only an accurate injection and hereby a higher successful rate but also significantly decreased mortality rate, as compared to our previous manual procedure. In vivo high resolution MRI allows the visualization of hyperintense multifocal lesions, as small as 310 µm in diameter on T2-weighted images at 3 weeks post injection. Follow-up MRI reveals intracranial tumor growth and increased number of metastases that distribute throughout the whole brain.

  14. Automated 3D ultrasound elastography of the breast: a phantom validation study

    Science.gov (United States)

    Hendriks, Gijs A. G. M.; Holländer, Branislav; Menssen, Jan; Milkowski, Andy; Hansen, Hendrik H. G.; de Korte, Chris L.

    2016-04-01

    In breast cancer screening, the automated breast volume scanner (ABVS) was introduced as an alternative for mammography since the latter technique is less suitable for women with dense breasts. Although clinical studies show promising results, clinicians report two disadvantages: long acquisition times (>90 s) introducing breathing artefacts, and high recall rates due to detection of many small lesions of uncertain malignant potential. Technical improvements for faster image acquisition and better discrimination between benign and malignant lesions are thus required. Therefore, the aim of this study was to investigate if 3D ultrasound elastography using plane-wave imaging is feasible. Strain images of a breast elastography phantom were acquired by an ABVS-mimicking device that allowed axial and elevational movement of the attached transducer. Pre- and post-deformation volumes were acquired with different constant speeds (between 1.25 and 40.0 mm s-1) and by three protocols: Go-Go (pre- and post-volumes with identical start and end positions), Go-Return (similar to Go-Go with opposite scanning directions) and Control (pre- and post-volumes acquired per position, this protocol can be seen as reference). Afterwards, 2D and 3D cross-correlation and strain algorithms were applied to the acquired volumes and the results were compared. The Go-Go protocol was shown to be superior with better strain image quality (CNRe and SNRe) than Go-Return and to be similar as Control. This can be attributed to applying opposite mechanical forces to the phantom during the Go-Return protocol, leading to out-of-plane motion. This motion was partly compensated by using 3D cross-correlation. However, the quality was still inferior to Go-Go. Since these results were obtained in a phantom study with controlled deformations, the effect of possible uncontrolled in vivo tissue motion artefacts has to be addressed in future studies. In conclusion, it seems feasible to implement 3D ultrasound

  15. Targeted Ultrasound for MR-Detected Lesions in Breast Cancer Patients

    International Nuclear Information System (INIS)

    Shin, Jung Hee; Han, Boo Kyung; Choe, Yeon Hyeon; Ko, Kyung Ran; Choi, Nami

    2007-01-01

    To investigate the usefulness of targeted ultrasound (US) in the identification of additional suspicious lesions found by magnetic resonance (MR) imaging in breast cancer patients and the changes in treatment based on the identification of the lesions by the use of targeted US. One-hundred forty nine patients who underwent breast MR imaging for a preoperative evaluation of breast cancer between January 2002 and July 2004 were included in the study. We searched all cases for any additional lesions that were found initially by MR imaging and investigated the performance of targeted US in identifying the lesions. We also investigated their pathological outcomes and changes in treatment as a result of lesion identification. Of the 149 patients with breast cancer, additional suspicious lesions were detected with MR imaging in 62 patients (42%). Of the 69 additional lesions found in those 62 patients, 26 (38%) were confirmed as cancers by histology. Thirty-eight lesions in 31 patients were examined with targeted US and were histologically revealed as cancers in 18 (47%), high risk lesions in two (5%), benign lesions in 15 (39%), and unidentified lesions in three (8%). The cancer rate was statistically higher in lesions with a US correlate than in lesions without a US correlate (p = 0.028). Of 31 patients, the surgical plan was altered in 27 (87%). The use of targeted US justified a change in treatment for 22 patients (81%) and misled five patients (19%) into having an unnecessary surgical excision. Targeted US can play a useful role in the evaluation of additional suspicious lesions detected by MR imaging in breast cancer patients, but is limited in lesions without a US correlate

  16. Breast ultrasound elastography-Results of 193 breast lesions in a prospective study with histopathologic correlation

    International Nuclear Information System (INIS)

    Schaefer, F.K.W.; Heer, I.; Schaefer, P.J.; Mundhenke, C.; Osterholz, S.; Order, B.M.; Hofheinz, N.; Hedderich, J.; Heller, M.; Jonat, W.; Schreer, I.

    2011-01-01

    Purpose: To evaluate the diagnostic performance of ultrasound elastography in breast masses. Material and methods: 193 lesions (129 benign, 64 malignant) were analyzed with the EUB 8500 Logos-ultrasonic-unit (Hitachi Medical, Japan) and a linear-array-transducer of 7.5-13-MHz. Standard of reference was cytology (FNAfine needle aspiration) or histology (core biopsy). The elastic-score was classified according to a 6-point colour-scale (Ueno classification; 1-3 = benign, 4-5 = malignant). Conventional B-mode ultrasound (US) findings were classified according to the BI-RADS classification. Statistical analysis included sensitivity, specificity, ROC-analysis and kappa-values for intra-/interobserver reliability. Results: The mean score for elasticity was 4.1 ± 0.9 for malignant lesions, and 2.1 ± 1.0 for benign lesions (p < 0.001). With a best cut-off point between elasticity scores 3 and 4, sensitivity was 96.9%, and specificity 76%. Setting a best cut-off point for conventional US between BI-RADS 4 and 5, sensitivity was 57.8%, and specificity 96.1%. Elastography provided higher sensitivity and lower specificity than conventional US, but two lesions with elasticity score 1 were false negative, whereas no lesion scored BI-RADS 1-3 were false negative. ROC-curve was 0.884 for elastography, and 0.820 for conventional US (p < 0.001). Weighted kappa-values for intra-/interobserver reliability were 0.784/0.634 for BI-RADS classification, and 0.720/0.561 for elasticity scores. Conclusion: In our study setting, elastography does not have the potential to replace conventional B-mode US for the detection of breast cancer, but may complement conventional US to improve the diagnostic performance.

  17. Indications for and comparative diagnostic value of combined ultrasound and X-ray mammography

    International Nuclear Information System (INIS)

    Novak, D.

    1983-01-01

    A standardised method of ultrasound mammography is described. In order to achieve the same position, form, and shape of the breast as during roentgen mammography a Lucite plate in horizontal, and vertical position us used. Ultrasound contact scanning of the whole breast is carried out in cranio-caudal as well as in medio-lateral direction of the ultrasound beam. Ultrasound scanning is performed with the compression of the breast corresponding to the compression during roentgen mammography. It was found that the ultrasound breast examination combined with X-ray mammography optimizes the differentiation between benign and malignant masses and therefore may reduce the incidence of breast biopsy. A combined use of both examination modalities in the evaluation of the breast is advocated. (orig.)

  18. ROLE OF ULTRASOUND IN EVALUATION OF BREAST DISEASES (WITH FOCUS ON BI-RADS 1-3 VS. BI-RADS 4-5: A STUDY OF 131 CASES

    Directory of Open Access Journals (Sweden)

    Pankaj Sharma

    2016-10-01

    Full Text Available BACKGROUND Ultrasound is a radiation free, readily available imaging modality that is routinely used for evaluation of breast. The patient usually are for routine checkup to nonspecific symptoms with few showing specific signs and symptoms. In this study, an attempt has been made to understand the role of ultrasound in diagnosing benign lesions with a drawback focused on early malignant lesion. Also, the differentiation of solid and cystic lesions can reduce biopsy. MATERIALS AND METHODS This study was done retrospectively evaluating 131 consecutive patients. The ultrasound study included evaluation of mainly female patients with few male cases. RESULTS Most common lesions were benign lesions. Among these benign lesions, fibroadenomas and fibrocystic disease were the commonest. However, there were no early malignant lesion seen in this study. CONCLUSION Breast ultrasound is choice of investigation in benign breast diseases. Also, such lesions can be easily followed up at primary level. However, there is a limited role in detecting early malignant lesions, which will require additional workup at a higher level especially in high-risk groups.

  19. Lutein Supplementation Increases Breast Milk and Plasma Lutein Concentrations in Lactating Women and Infant Plasma Concentrations but Does Not Affect Other Carotenoids123

    Science.gov (United States)

    Sherry, Christina L.; Oliver, Jeffery S.; Renzi, Lisa M.; Marriage, Barbara J.

    2014-01-01

    Lutein is a carotenoid that varies in breast milk depending on maternal intake. Data are lacking with regard to the effect of dietary lutein supplementation on breast milk lutein concentration during lactation and subsequent plasma lutein concentration in breast-fed infants. This study was conducted to determine the impact of lutein supplementation in the breast milk and plasma of lactating women and in the plasma of breast-fed infants 2–3 mo postpartum. Lutein is the dominant carotenoid in the infant brain and the major carotenoid found in the retina of the eye. Eighty-nine lactating women 4–6 wk postpartum were randomly assigned to be administered either 0 mg/d of lutein (placebo), 6 mg/d of lutein (low-dose), or 12 mg/d of lutein (high-dose). The supplements were consumed for 6 wk while mothers followed their usual diets. Breast milk carotenoids were measured weekly by HPLC, and maternal plasma carotenoid concentrations were measured at the beginning and end of the study. Infant plasma carotenoid concentrations were assessed at the end of the study. No significant differences were found between dietary lutein + zeaxanthin intake and carotenoid concentrations in breast milk and plasma or body mass index at baseline. Total lutein + zeaxanthin concentrations were greater in the low- and high-dose–supplemented groups than in the placebo group in breast milk (140% and 250%, respectively; P Lutein supplementation did not affect other carotenoids in lactating women or their infants. Lactating women are highly responsive to lutein supplementation, which affects plasma lutein concentrations in the infant. This trial was registered at clinicaltrials.gov as NCT01747668. PMID:24899160

  20. Intake of vitamins A, C, and E from diet and supplements and breast cancer in postmenopausal women

    DEFF Research Database (Denmark)

    Nissen, S. B.; Tjonneland, A.; Stripp, C.

    2003-01-01

    Objective: The influence of the vitamins A, C, and E on breast cancer development has not been clarified. An effect of a vitamin per se implicates similar patterns for the effects of the vitamin from dietary and supplemental sources. We examined how the breast cancer incidence rate among...... A or E for postmenopausal women. For vitamin C we found an increase in breast cancer rate with increasing intake....... postmenopausal women was related to intake of vitamins A, C, and E from diet and supplements. Methods: Data was sampled as case - control nested within the Danish 'Diet, Cancer and Health' cohort. Data on vitamin intakes were collected at entry into the cohort by means of self-administered questionnaires. Women...

  1. Automated Breast Ultrasound for Ductal Pattern Reconstruction: Ground Truth File Generation and CADe Evaluation

    Science.gov (United States)

    Manousaki, D.; Panagiotopoulou, A.; Bizimi, V.; Haynes, M. S.; Love, S.; Kallergi, M.

    2017-11-01

    The purpose of this study was the generation of ground truth files (GTFs) of the breast ducts from 3D images of the Invenia™ Automated Breast Ultrasound System (ABUS) system (GE Healthcare, Little Chalfont, UK) and the application of these GTFs for the optimization of the imaging protocol and the evaluation of a computer aided detection (CADe) algorithm developed for automated duct detection. Six lactating, nursing volunteers were scanned with the ABUS before and right after breastfeeding their infants. An expert in breast ultrasound generated rough outlines of the milk-filled ducts in the transaxial slices of all image volumes and the final GTFs were created by using thresholding and smoothing tools in ImageJ. In addition, a CADe algorithm automatically segmented duct like areas and its results were compared to the expert’s GTFs by estimating true positive fraction (TPF) or % overlap. The CADe output differed significantly from the expert’s but both detected a smaller than expected volume of the ducts due to insufficient contrast (ducts were partially filled with milk), discontinuities, and artifacts. GTFs were used to modify the imaging protocol and improve the CADe method. In conclusion, electronic GTFs provide a valuable tool in the optimization of a tomographic imaging system, the imaging protocol, and the CADe algorithms. Their generation, however, is an extremely time consuming, strenuous process, particularly for multi-slice examinations, and alternatives based on phantoms or simulations are highly desirable.

  2. Prototype volumetric ultrasound tomography image guidance system for prone stereotactic partial breast irradiation: proof-of-concept

    Science.gov (United States)

    Chiu, Tsuicheng D.; Parsons, David; Zhang, Yue; Hrycushko, Brian; Zhao, Bo; Chopra, Rajiv; Kim, Nathan; Spangler, Ann; Rahimi, Asal; Timmerman, Robert; Jiang, Steve B.; Lu, Weiguo; Gu, Xuejun

    2018-03-01

    Accurate dose delivery in stereotactic partial breast irradiation (S-PBI) is challenging because of the target position uncertainty caused by breast deformation, the target volume changes caused by lumpectomy cavity shrinkage, and the target delineation uncertainty on simulation computed tomography (CT) images caused by poor soft tissue contrast. We have developed a volumetric ultrasound tomography (UST) image guidance system for prone position S-PBI. The system is composed of a novel 3D printed rotation water tank, a patient-specific resin breast immobilization cup, and a 1D array ultrasound transducer. Coronal 2D US images were acquired in 5° increments over a 360° range, and planes were acquired every 2 mm in elevation. A super-compounding technique was used to reconstruct the image volume. The image quality of UST was evaluated with a BB-1 breast phantom and BioZorb surgical marker, and the results revealed that UST offered better soft tissue contrast than CT and similar image quality to MR. In the evaluated plane, the size and location of five embedded objects were measured and compared to MR, which is considered as the ground truth. Objects’ diameters and the distances between objects in UST differ by approximately 1 to 2 mm from those in MR, which showed that UST offers the image quality required for S-PBI. In future work we will develop a robotic system that will be ultimately implemented in the clinic.

  3. Added value of Virtual Touch IQ shear wave elastography in the ultrasound assessment of breast lesions.

    Science.gov (United States)

    Ianculescu, Victor; Ciolovan, Laura Maria; Dunant, Ariane; Vielh, Philippe; Mazouni, Chafika; Delaloge, Suzette; Dromain, Clarisse; Blidaru, Alexandru; Balleyguier, Corinne

    2014-05-01

    To determine the diagnostic performance of Acoustic Radiation Force Impulse (ARFI) Virtual Touch IQ shear wave elastography in the discrimination of benign and malignant breast lesions. Conventional B-mode and elasticity imaging were used to evaluate 110 breast lesions. Elastographic assessment of breast tissue abnormalities was done using a shear wave based technique, Virtual Touch IQ (VTIQ), implemented on a Siemens Acuson S3000 ultrasound machine. Tissue mechanical properties were interpreted as two-dimensional qualitative and quantitative colour maps displaying relative shear wave velocity. Wave speed measurements in m/s were possible at operator defined regions of interest. The pathologic diagnosis was established on samples obtained by ultrasound guided core biopsy or fine needle aspiration. BIRADS based B-mode evaluation of the 48 benign and 62 malignant lesions achieved 92% sensitivity and 62.5% specificity. Subsequently performed VTIQ elastography relying on visual interpretation of the colour overlay displaying relative shear wave velocities managed similar standalone diagnostic performance with 92% sensitivity and 64.6% specificity. Lesion and surrounding tissue shear wave speed values were calculated and a significant difference was found between the benign and malignant populations (Mann-Whitney U test, pmasses, we reached overall levels of 92% sensitivity and 72.9% specificity. VTIQ qualitative and quantitative elastography has the potential to further characterise B-mode detected breast lesions, increasing specificity and reducing the number of unnecessary biopsies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Application of Artificial Neural Network Models in Segmentation and Classification of Nodules in Breast Ultrasound Digital Images

    Directory of Open Access Journals (Sweden)

    Karem D. Marcomini

    2016-01-01

    Full Text Available This research presents a methodology for the automatic detection and characterization of breast sonographic findings. We performed the tests in ultrasound images obtained from breast phantoms made of tissue mimicking material. When the results were considerable, we applied the same techniques to clinical examinations. The process was started employing preprocessing (Wiener filter, equalization, and median filter to minimize noise. Then, five segmentation techniques were investigated to determine the most concise representation of the lesion contour, enabling us to consider the neural network SOM as the most relevant. After the delimitation of the object, the most expressive features were defined to the morphological description of the finding, generating the input data to the neural Multilayer Perceptron (MLP classifier. The accuracy achieved during training with simulated images was 94.2%, producing an AUC of 0.92. To evaluating the data generalization, the classification was performed with a group of unknown images to the system, both to simulators and to clinical trials, resulting in an accuracy of 90% and 81%, respectively. The proposed classifier proved to be an important tool for the diagnosis in breast ultrasound.

  5. Histological diagnosis of ultrasound-visible breast lesions by large core needle biopsy

    International Nuclear Information System (INIS)

    Sanchis-Querol, E.; Valeros, O.; Collado, A.; Gimenez, J.; Yanguas, C.

    1999-01-01

    We present our experience in the histological diagnosis of breast lesions using ultrasound-guided large core needle biopsy (LCNB), assessing its utility as an alternative to excisional biopsy. We have studied retrospectively a series of 146 cases involving the performance of LCNB. The results were comparable with those of FNAB in 59 cases and with those of surgical aspiration biopsy in 105. Of the 113 lesions identified as malignant by percutaneous large core needle aspiration biopsy, 96 were resected. Surgical aspiration biopsy agreed with LCNB in 100% of cases. Of the 33 lesions identified as benign by LCNB, surgical biopsy detected malignancy in 5. The results obtained establish a specificity for LCNB of 100% and a sensitivity of 96%, both of which are superior to the values for FNAB. Thus, this technique can be considered valid for preoperative diagnosis. LCNB is useful in the preoperative diagnosis of breast lesions, making FNAB and surgical biopsy unnecessary. Moreover, it constitutes a significant change in the management of patients with malignant or undetermined breast lesions. (Author) 8 refs

  6. Ultrasound guided pO2 measurement of breast cancer reoxygenation after neoadjuvant chemotherapy and hyperthermia treatment.

    Science.gov (United States)

    Vujaskovic, Z; Rosen, E L; Blackwell, K L; Jones, E L; Brizel, D M; Prosnitz, L R; Samulski, T V; Dewhirst, M W

    2003-01-01

    The objective of this study was to determine whether neoadjuvant chemotherapy in combination with hyperthermia (HT) would improve oxygenation in locally advanced breast tumours. The study describes a new optimized ultrasound guided technique of pO2 measurement using Eppendorf polarographic oxygen probes in 18 stage IIB-III breast cancer patients. Prior to treatment, tumour hypoxia (median pO2pO2=3.2 mmHg). Seven patients had well oxygenated tumours (median pO2 of 48.3 mmHg). Eight patients with hypoxic tumours prior to treatment had a significant improvement (p=0.0008) in tumour pO2 after treatment (pO2 increased to 19.2 mmHg). In three patients, tumours remained hypoxic (average median pO2=4.5 mmHg). The advantages of the ultrasound guided pO2 probe are in the accuracy of the Eppendorf electrode placement in tumour tissue, the ability to monitor electrode movement through the tumour tissue during the measurement and the ability to avoid electrode placement near or in large blood vessels by using colour Doppler imaging. The results of this preliminary study suggest that the combination of neoadjuvant chemotherapy and hyperthermia improves oxygenation in locally advanced breast tumours that are initially hypoxic.

  7. Characteristics of breast cancers detected by ultrasound screening in women with negative mammograms

    International Nuclear Information System (INIS)

    Bae, Min-Sun; Han, Wonshik; Koo, Hye-Ryoung

    2011-01-01

    Screening ultrasound (US) can increase the detection of breast cancer. However, little is known about the clinicopathologic characteristics of breast cancers detected by screening US. A search of the database for patients with breast cancer yielded a dataset in 6837 women who underwent breast surgery at Seoul National University Hospital (Korea). Of 6837 women, 1047 were asymptomatic and had a non-palpable cancer. Two hundred fifty-four women with 256 cancers detected by US (US-detected cancer) and 793 women with 807 cancers detected by mammography (MG-detected cancer) were identified. The imaging, clinicopathologic, and molecular data were reviewed. Univariate and multivariate analyses were carried out. Women with US-detected cancer were younger and were more likely to undergo breast-conserving surgery and to have node-negative invasive cancer (P 2 cm in size, tumors that were ≤1 cm in size were 2.2-fold more likely to be US-detected cancers (P=0.02). Compared to the luminal A subtype tumors (estrogen receptor [ER]+, PR+, HER2-), luminal B subtype tumors (ER+, PR+, HER2+) were less likely to be in the US-detected cancer group (P<0.01). Women with dense breasts were more likely to have US-detected cancer (P<0.01) versus those with non-dense breasts. Screening US-detected cancers were less likely to be diagnosed as category 5 instead of category 4 (P<0.01). In conclusion, women with US-detected breast cancer are more likely to have small-sized invasive cancer and more likely associated with the luminal A subtype. (author)

  8. MRI screening-detected breast lesions in high-risk young women: the value of targeted second-look ultrasound and imaging-guided biopsy.

    Science.gov (United States)

    Peter, P; Dhillon, R; Bose, S; Bourke, A

    2016-10-01

    To analyse the value of targeted second-look ultrasound and imaging-guided biopsy in high-risk young women eligible for screening magnetic resonance imaging (MRI) in a tertiary referral centre in Perth, Western Australia. A retrospective analysis of eligible high-risk young women who underwent screening breast MRI and targeted second-look ultrasound between June 2012 and June 2014 was performed with review of data. Over a 2-year period, 139 women underwent high-risk screening MRI. Of these, 30 women (with a total of 45 lesions) were recalled for targeted second-look ultrasound. Thirty-four MRI-detected lesions were identified on targeted ultrasound with 19 of them proceeding to ultrasound-guided biopsy, while the remaining 15 lesions were considered benign on ultrasound, were not biopsied, and were stable on follow-up imaging 12 months later. One lesion proceeded to an MRI-guided biopsy to confirm a benign result. Of the 11 lesions not seen on ultrasound, nine underwent MRI biopsy, one proceeded directly to hook wire localisation and excision, and one did not return for biopsy and was lost to follow-up. The overall biopsy rate was 14.4%. The cancer detection rate was 1.4%. The results of this study indicate that targeted second-look ultrasound and ultrasound-guided biopsy is a cost-effective and time-efficient approach for MRI-detected lesions in young women at high risk of developing breast cancer. MRI-guided biopsy should be considered for ultrasonographically occult suspicious lesions as there is a low, but definite, risk of cancer. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  10. Breast ultrasound tomography: bridging the gap to clinical practice

    Science.gov (United States)

    Duric, Neb; Littrup, Peter; Li, Cuiping; Roy, Olivier; Schmidt, Steven; Janer, Roman; Cheng, Xiaoyang; Goll, Jeffrey; Rama, Olsi; Bey-Knight, Lisa; Greenway, William

    2012-03-01

    Conventional sonography, which performs well in dense breast tissue and is comfortable and radiation-free, is not practical for screening because of its operator dependence and the time needed to scan the whole breast. While magnetic resonance imaging (MRI) can significantly improve on these limitations, it is also not practical because it has long been prohibitively expensive for routine use. There is therefore a need for an alternative breast imaging method that obviates the constraints of these standard imaging modalities. The lack of such an alternative is a barrier to dramatically impacting mortality (about 45,000 women in the US per year) and morbidity from breast cancer because, currently, there is a trade-off between the cost effectiveness of mammography and sonography on the one hand and the imaging accuracy of MRI on the other. This paper presents a progress report on our long term goal to eliminate this trade-off and thereby improve breast cancer survival rates and decrease unnecessary biopsies through the introduction of safe, cost-effective, operatorindependent sonography that can rival MRI in accuracy. The objective of the study described in this paper was to design and build an improved ultrasound tomography (UST) scanner in support of our goals. To that end, we report on a design that builds on our current research prototype. The design of the new scanner is based on a comparison of the capabilities of our existing prototype and the performance needed for clinical efficacy. The performance gap was quantified by using clinical studies to establish the baseline performance of the research prototype, and using known MRI capabilities to establish the required performance. Simulation software was used to determine the basic operating characteristics of an improved scanner that would provide the necessary performance. Design elements focused on transducer geometry, which in turn drove the data acquisition system and the image reconstruction engine

  11. Technical quality assessment of breast ultrasound according to American College of Radiology (ACR) Standards

    International Nuclear Information System (INIS)

    Ko, Kyung Hee; Kim, Eun Kyung; Kim, Young Ah; Son, Eun Ju; Oh, Ki Keun; Chung, Sun Yang

    2003-01-01

    To evaluate the technical quality of breast ultrasound based on American College of Radiology(ACR) standards. Between March 2002 and July 2002, ninety three breast sonograms obtained from 73 institutions were evaluated based on ACR standards for the hardware, technical settings, labeling of the images and identification. Of 93 breast sonograms, a satisfactory compliance with all ACR standards in the performance of breast US examinations was documented in 31% while the remaining 69% did not fully meet all ACR standards. 4.3% of breast US examinations were performed with a convex transducers, and the focal zone was inappropriately positioned in 14.2%. Gray-scale gain was subjectively characterized as inappropriate in 26.9%, and the size of lesion was not measured in 7.5%. Anatomic location of lesions was inappropriately described in 9.3%. The orientation of an US transducer was not properly labeled on any images in 33.3%. Inadequate recording of patient's information was noted in 43.3%. 50% of sonograms at University medical centers and larger general hospitals fully met all ACR standards while 36.8% at radiologic clinics and 12.1% at other private clinics met all ACR standards. Overall, 69% of breast sonograms failed to meet the quality criteria of the ACR standards. Therefore, it is essential to educate the basic technical details in performing breast US for the quality control.

  12. Breast infection

    Science.gov (United States)

    Mastitis; Infection - breast tissue; Breast abscess ... must continue to breastfeed or pump to relieve breast swelling from milk production. In case if the abscess does not go away, needle aspiration under ultrasound ...

  13. Micronutrient supplements during pregnancy and/or lactation in Malawi and Ghana increase breast milk B-vitamins [abstract

    Science.gov (United States)

    There are few data available on the effect of micronutrient (MN) supplementation interventions during pregnancy/lactation on breast milk (BM) MN concentrations. Exclusive breast feeding is recommended fort 6mo and BM-MN concentrations are important determinants of infant MN status, growth and devel...

  14. B-Vitamin Intake from Diet and Supplements and Breast Cancer Risk in Middle-Aged Women: Results from the Prospective NutriNet-Santé Cohort.

    Science.gov (United States)

    Egnell, Manon; Fassier, Philippine; Lécuyer, Lucie; Zelek, Laurent; Vasson, Marie-Paule; Hercberg, Serge; Latino-Martel, Paule; Galan, Pilar; Deschasaux, Mélanie; Touvier, Mathilde

    2017-05-13

    Experimental studies suggest a protective effect of B-vitamins on breast cancer risk, potentially modulated by alcohol intake. However, epidemiological studies are limited, especially regarding non-folate B-vitamins. Furthermore, few studies included quantitative assessment of supplemental intake. This prospective study aimed to investigate the associations between intakes of B-vitamins (dietary, supplemental, total) and breast cancer risk. 27,853 women aged ≥45 years from the NutriNet-Santé cohort (2009-2016) were included, with a median follow-up time of 4.2 years. Dietary data were collected using repeated 24 h records. A specific questionnaire assessed dietary supplement use over a 12-month period. A composition database of 8000 supplements was developed. Associations were characterized by multivariable Cox models, and 462 incident breast cancers were diagnosed. Dietary (HR Q4vs.Q1 = 0.74 (0.55, 0.99), P -trend = 0.05), supplemental (HR Q4vs.Q1 = 0.61 (0.38, 0.98), P -trend = 0.05), and total (HR Q4vs.Q1 = 0.67 (0.50, 0.91), P -trend = 0.01) pyridoxine intakes were inversely associated with breast cancer risk. Total thiamin intake was borderline inversely associated with breast cancer risk (HR per 1-unit increment = 0.78 (0.61, 1.00), P = 0.05). Statistically significant interactions between alcohol consumption and B-vitamin (thiamin, riboflavin, niacin, pantothenic acid, pyridoxine, folate, and cobalamin) supplemental intake were observed, the latter being inversely associated with breast cancer risk in non-to-low alcohol drinkers but not in higher drinkers. This large prospective study, including quantitative assessment of supplemental intake, suggests a potential protective effect of pyridoxine and thiamin on breast cancer risk in middle-aged women.

  15. Contrast-enhanced color Doppler ultrasound characteristics in hypervascular breast tumors: comparison with MRI

    International Nuclear Information System (INIS)

    Alamo, L.; Fischer, U.

    2001-01-01

    The aim of this study was to evaluate the accuracy of contrast-enhanced color Doppler ultrasound (CE-US) in comparison with contrast-enhanced MR imaging (CE-MRI) in the discrimination of hypervascularized breast tumors. An additional CE-US of the breast was preoperatively performed in 40 patients with a hypervascular breast lesion detected on CE-MRI. The presence of blood flow signals and the morphological characteristics of the vessels in the breast lesions were evaluated pre- and post-contrast administration, as well as the dynamic aspects of the Doppler signal, including time interval to maximum signal enhancement and persistence of the signal enhancement. Twenty-three carcinomas and 17 fibroadenomas were explored. Considering initial signal enhancement > 100 % after the administration of contrast material as a criterion suggesting malignancy, CE-MRI showed a sensitivity of 100 % and a specificity of 76.5 % in the detection of malignant breast tumors. Color Doppler signals were consistently demonstrated in all carcinomas and in 68.7 % of fibroadenomas after the administration of Levovist, with CE-US showing a sensitivity of 95.6 % and a specificity of 5.9 %. Neither the mean number of vessels per tumor, nor the location of vessels, the time to maximum increase of the Doppler signal or the persistence of signal enhancement showed significant differences between benign and malignant lesions. Additional CE-US does not increase the low specificity of MRI in patients with hypervascularized breast tumors. (orig.)

  16. Predictive values of Bi-Rads categories 3, 4 and 5 in non-palpable breast masses evaluated by mammography, ultrasound and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Roveda Junior, Decio; Fleury, Eduardo de Castro Faria; Piato, Sebastiao; Oliveira, Vilmar Marques de; Rinaldi, Jose Francisco; Ferreira, Carlos Alberto Pecci

    2007-01-01

    Objective: To evaluate the predictive value of BI-RADS TM categories 3, 4 and 5 in non-palpable breast masses assessed by mammography, ultrasound and magnetic resonance imaging. Materials And Methods: Twenty-nine patients with BI-RADS categories 3, 4 and 5 non-palpable breast masses identified by mammograms were submitted to complementary ultrasound and magnetic resonance imaging studies, besides excisional biopsy. In total, 30 biopsies were performed. The lesions as well as their respective BI-RADS classification into 3, 4 and 5 were correlated with the histopathological results. The predictive values calculation was made by means of specific mathematical equations. Results: Negative predictive values for category 3 were: mammography, 69.23%; ultrasound, 70.58%; and magnetic resonance imaging, 100%. Positive predictive values for category 4 were: mammography, 63.63%; ultrasound, 50%; and magnetic resonance imaging, 30.76%. For category 5, positive predictive values were: mammography and ultrasound, 100%; and magnetic resonance imaging, 92.85%. Conclusion: For category 3, the negative predictive value of magnetic resonance imaging was high, and for categories 4 and 5, the positive predictive values of the three modalities were moderate. (author)

  17. The role of ultrasound and lymphoscintigraphy in the assessment of axillary lymph nodes in patients with breast cancer

    Directory of Open Access Journals (Sweden)

    Michał Nieciecki

    2016-03-01

    Full Text Available Breast cancer is the most common malignancy and the leading cause of death due to cancer in European women. Mammography screening programs aimed to increase the detection of early cancer stages were implemented in numerous European countries. Recent data show a decrease in mortality due to breast cancer in many countries, particularly among young women. At the same time, the number of sentinel node biopsy procedures and breast-conserving surgeries has increased. Intraoperative sentinel lymph node biopsy preceded by lymphoscintigraphy is used in breast cancer patients with no clinical signs of lymph node metastasis. Due to the limited sensitivity and specificity of physical examination in detecting metastatic lesions, developing an appropriate diagnostic algorithm for the preoperative assessment of axillary lymph nodes seems to be a challenge. The importance of ultrasound in patient qualification for sentinel lymph-node biopsy has been discussed in a number of works. Furthermore, different lymphoscintigraphy protocols have been compared in the literature. The usefulness of novel radiopharmaceuticals as well as the methods of image acquisition in sentinel lymph node diagnostics have also been assessed. The aim of this article is to present, basing on current guidelines, literature data as well as our own experience, the diagnostic possibilities of axillary lymph node ultrasound in patient qualification for an appropriate treatment as well as the role of lymphoscintigraphy in sentinel lymph node biopsy.

  18. Lutein Supplementation Increases Breast Milk and Plasma Lutein Concentrations in Lactating Women and Infant Plasma Concentrations but Does Not Affect Other Carotenoids 1 2 3

    OpenAIRE

    Sherry, Christina L.; Oliver, Jeffery S.; Renzi, Lisa M.; Marriage, Barbara J.

    2014-01-01

    Lutein is a carotenoid that varies in breast milk depending on maternal intake. Data are lacking with regard to the effect of dietary lutein supplementation on breast milk lutein concentration during lactation and subsequent plasma lutein concentration in breast-fed infants. This study was conducted to determine the impact of lutein supplementation in the breast milk and plasma of lactating women and in the plasma of breast-fed infants 2–3 mo postpartum. Lutein is the dominant carotenoid in t...

  19. Individually and Combined Water-Based Exercise With Ginger Supplement, on Systemic Inflammation and Metabolic Syndrome Indices, Among the Obese Women With Breast Neoplasms.

    Science.gov (United States)

    Karimi, Niloofar; Dabidi Roshan, Valiollah; Fathi Bayatiyani, Zohreh

    2015-12-01

    Breast neoplasms has known as the most common cancer among the women worldwide, and relationship between obesity, metabolic syndrome, inflammation and cancer has been recognized since many years ago. The aim of this study was to determine the individual and concomitant effect of 6-weeks water-based exercise and oral ginger supplement on markers that have related to metabolic syndrome and systemic inflammation in obese women with breast neoplasms. Forty women whose have diagnosed with breast neoplasms have volunteered to participate in the study. Subjects have randomly assigned into four groups; placebo, exercise training, ginger supplement and exercise training+ ginger supplement groups. Subjects in the ginger supplement group and the exercise training+ ginger supplement group have orally received 4 capsules, 7 days a week and for 6 weeks. The water-based exercise training program have collected at a progressive intensity and time, have ranged from 50% to 75% of heart rate reserve, in a pool, 4 times a week for 6 weeks. Fasting blood sampling has collected at the pretest and post-test. The ginger supplementation and the water-base exercise have resulted in a reduction of hs-CRP, IL-10, insulin, glucose, insulin resistance, LDL-C, TG; but an increase in HDL-C and HDL-C/LDL-C. The water-base exercise and ginger supplement group have significantly shown larger positive effect in all outcomes, in comparison with the water-base exercise or ginger supplement alone groups. Findings have suggested that obese breast neoplasms survivors have commonly shown metabolic syndrome and elevated inflammation, which placed them at an increased risk for cardiovascular diseases. Moreover, data has indicated a protective effect of the nondrug strategies, such as water-base exercise and ginger supplementation have played an important role in pathogenesis of inflammatory and metabolic responses, among diagnosed breast neoplasms.

  20. Automated 3D ultrasound elastography of the breast: a phantom validation study

    International Nuclear Information System (INIS)

    Hendriks, Gijs A G M; Holländer, Branislav; Menssen, Jan; Hansen, Hendrik H G; De Korte, Chris L; Milkowski, Andy

    2016-01-01

    In breast cancer screening, the automated breast volume scanner (ABVS) was introduced as an alternative for mammography since the latter technique is less suitable for women with dense breasts. Although clinical studies show promising results, clinicians report two disadvantages: long acquisition times (>90 s) introducing breathing artefacts, and high recall rates due to detection of many small lesions of uncertain malignant potential. Technical improvements for faster image acquisition and better discrimination between benign and malignant lesions are thus required. Therefore, the aim of this study was to investigate if 3D ultrasound elastography using plane-wave imaging is feasible. Strain images of a breast elastography phantom were acquired by an ABVS-mimicking device that allowed axial and elevational movement of the attached transducer. Pre- and post-deformation volumes were acquired with different constant speeds (between 1.25 and 40.0 mm s −1 ) and by three protocols: Go–Go (pre- and post-volumes with identical start and end positions), Go–Return (similar to Go–Go with opposite scanning directions) and Control (pre- and post-volumes acquired per position, this protocol can be seen as reference). Afterwards, 2D and 3D cross-correlation and strain algorithms were applied to the acquired volumes and the results were compared. The Go–Go protocol was shown to be superior with better strain image quality (CNR e and SNR e ) than Go–Return and to be similar as Control. This can be attributed to applying opposite mechanical forces to the phantom during the Go–Return protocol, leading to out-of-plane motion. This motion was partly compensated by using 3D cross-correlation. However, the quality was still inferior to Go–Go. Since these results were obtained in a phantom study with controlled deformations, the effect of possible uncontrolled in vivo tissue motion artefacts has to be addressed in future studies. In conclusion, it seems feasible to

  1. Characterization of focal breast lesions by means of elastography.

    Science.gov (United States)

    Fischer, T; Sack, I; Thomas, A

    2013-09-01

    The modern method of sonoelastography of the breast is used for differentiating focal lesions. This review gives an overview of the different techniques available and discusses their roles in the routine clinical setting. The presented techniques include compression or vibration elastography as well as shear wave elastography. Descriptions of the methods are supplemented by a discussion of the clinical role of each technique based on the most recent literature. We discuss by outlining two recent experimental approaches - MRI and tomosynthesis elastography. Currently available data suggest that elastography is an important supplementary tool for the differentiation of breast tumors under routine clinical conditions. The specificity improves with the immediate availability of additional diagnostic information using real-time techniques and/or the calculation of strain ratios (SR). Elastography is especially helpful in women with involuted breasts for differentiating BI-RADS-US 3 and 4 lesions and for evaluating very small cancers without the typical imaging features of malignancy. Here, elastography techniques are highly specific, while the sensitivity decreases compared to B-mode ultrasound. SR calculation is especially helpful in women who have a high risk of breast cancer and high pretest likelihood. B-mode ultrasound is still the first-line method for the initial evaluation of the breast. If suspicious findings are detected, elastography with or without SR calculation is the most crucial supplementary tool. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Breast cancer detection using sonography in women with mammographically dense breasts

    International Nuclear Information System (INIS)

    Okello, Jimmy; Kisembo, Harriet; Bugeza, Sam; Galukande, Moses

    2014-01-01

    Mammography, the gold standard for breast cancer screening misses some cancers, especially in women with dense breasts. Breast ultrasonography as a supplementary imaging tool for further evaluation of symptomatic women with mammographically dense breasts may improve the detection of mass lesions otherwise missed at mammography. The purpose of this study was to determine the incremental breast cancer detection rate using US scanning in symptomatic women with mammographically dense breasts in a resource poor environment. A cross sectional descriptive study. Women referred for mammography underwent bilateral breast ultrasound, and mammography for symptom evaluation. The lesions seen by both modalities were described using sonographic BI-RADS lexicon and categorized. Ultrasound guided core biopsies were performed. IRB approval was obtained and all participants provided informed written consent. In total 148 women with mammographically dense breasts were recruited over six months. The prevalence of breast cancer in symptomatic women with mammographically dense breasts was 22/148 (15%). Mammography detected 16/22 (73%) of these cases and missed 6/22 (27%). The six breast cancer cases missed were correctly diagnosed on breast ultrasonography. Sonographic features typical of breast malignancy were irregular shape, non-parallel orientation, non circumscribed margin, echogenic halo, and increased lesion vascularity (p values < 0.005). Typical sonofeatures of benign mass lesions were: oval shape, parallel orientation and circumscribed margin (p values <0.005). Breast ultrasound scan as a supplementary imaging tool detected 27% more malignant mass lesions otherwise missed by mammography among these symptomatic women with mammographically dense breasts. We recommend that ultra sound scanning in routine evaluation of symptomatic women with mammographically dense breasts

  3. Developing an emergency ultrasound app

    DEFF Research Database (Denmark)

    Foss, Kim Thestrup; Subhi, Yousif; Aagaard, Rasmus

    2015-01-01

    Focused emergency ultrasound is rapidly evolving as a clinical skill for bedside examination by physicians at all levels of education. Ultrasound is highly operator-dependent and relevant training is essential to ensure appropriate use. When supplementing hands-on focused ultrasound courses, e-le...

  4. Ultrasound-Assisted Thoracic Paravertebral Block Reduces Intraoperative Opioid Requirement and Improves Analgesia after Breast Cancer Surgery: A Randomized, Controlled, Single-Center Trial.

    Directory of Open Access Journals (Sweden)

    Lijian Pei

    Full Text Available The contribution of ultrasound-assisted thoracic paravertebral block to postoperative analgesia remains unclear. We compared the effect of a combination of ultrasound assisted-thoracic paravertebral block and propofol general anesthesia with opioid and sevoflurane general anesthesia on volatile anesthetic, propofol and opioid consumption, and postoperative pain in patients having breast cancer surgery.Patients undergoing breast cancer surgery were randomly assigned to ultrasound-assisted paravertebral block with propofol general anesthesia (PPA group, n = 121 or fentanyl with sevoflurane general anesthesia (GA group, n = 126. Volatile anesthetic, propofol and opioid consumption, and postoperative pain intensity were compared between the groups using noninferiority and superiority tests.Patients in the PPA group required less sevoflurane than those in the GA group (median [interquartile range] of 0 [0, 0] vs. 0.4 [0.3, 0.6] minimum alveolar concentration [MAC]-hours, less intraoperative fentanyl requirements (100 [50, 100] vs. 250 [200, 300]μg,, less intense postoperative pain (median visual analog scale score 2 [1, 3.5] vs. 3 [2, 4.5], but more propofol (median 529 [424, 672] vs. 100 [100, 130] mg. Noninferiority was detected for all four outcomes; one-tailed superiority tests for each outcome were highly significant at P<0.001 in the expected directions.The combination of propofol anesthesia with ultrasound-assisted paravertebral block reduces intraoperative volatile anesthetic and opioid requirements, and results in less post operative pain in patients undergoing breast cancer surgery.ClinicalTrial.gov NCT00418457.

  5. Breast MRI scan

    Science.gov (United States)

    ... or breast ultrasound Evaluate for possible rupture of breast implants Find any cancer that remains after surgery or chemotherapy Show blood ... Mean Abnormal results may be due to: Breast cancer Cysts Leaking or ruptured breast implants Abnormal breast tissue that is not cancer Scar ...

  6. Imprint cytology from ultrasound-guided core biopsies: accurate and immediate diagnosis in a one-stop breast clinic

    International Nuclear Information System (INIS)

    Jones, L.; Lott, M.F.; Calder, C.J.; Kutt, E.

    2004-01-01

    AIM: To investigate whether imprint cytology from ultrasound-guided core biopsy specimens was adequate for the National Health Service Breast Screening Programme (NHSBSP) guidelines. METHODS: We prospectively audited imprint cytology from ultrasound-guided core biopsy specimens. The performance indicators for imprint cytology specimens from 111 consecutive ultrasound-guided core biopsy were compared with standards set by the NHSBSP for fine-needle aspiration cytology (FNAC). RESULTS: Imprint cytology fulfilled the 'preferred' targets for absolute and complete sensitivity, specificity, positive predictive value, false-positive and false-negative rates, inadequate rate and inadequate rate from cancers. It also satisfied the minimum target for suspicious rate. The complete sensitivity was 97%, full specificity 78%, with 100% positive predictive value for C5 cytology and an inadequate rate from cancers of 1.5%. CONCLUSION: Imprint cytology from ultrasound-guided core biopsy allows same-day diagnosis and the collection of data regarding the grade of the carcinoma for treatment decisions from a single needle test

  7. MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques

    Energy Technology Data Exchange (ETDEWEB)

    Imschweiler, Thomas; Freiwald, Bianka; Kubik-Huch, Rahel A. [Kantonspital Baden AG, Institute for Radiology, Baden (Switzerland); Haueisen, Harald [Kantonspital Aarau AG, Institute for Radiology, Aarau (Switzerland); Kampmann, Gert [Clinica Sant' Anna, Lugano, Sorengo (Switzerland); Rageth, Luzi [Adjumed Services AG, Zurich (Switzerland); Seifert, Burkhardt [Institute for Social and Preventive Medicine, University of Zurich, Division of Biostatistics, Zuerich (Switzerland); Rageth, Christoph [Breast Centre, Zurich (Switzerland)

    2014-01-15

    To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. (orig.)

  8. A contrast-enhanced ultrasound study of benign and malignant ...

    African Journals Online (AJOL)

    A contrast-enhanced ultrasound study of benign and malignant breast tissue. S Barnard, E Leen, T Cooke, W Angerson. Abstract. Objective. To determine the diagnostic value of haemodynamic contrast-enhanced ultrasound assessment in benign and malignant breast tissue, using histological examination as the reference ...

  9. Ultrasound characterization of breast masses

    International Nuclear Information System (INIS)

    Gokhale, Sudheer

    2009-01-01

    A lump in the breast is a cause of great concern. High frequency, high-resolution USG helps in its evaluation. This is exemplified in women with dense breast tissue where USG is useful in detecting small breast cancers that are not seen on mammography. Several studies in the past have addressed the issue of differentiating benign from malignant lesions in the breast. The American College of Radiology has also brought out a BIRADS-US classification system for categorizing focal breast lesions

  10. Added value of Virtual Touch IQ shear wave elastography in the ultrasound assessment of breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Ianculescu, Victor; Ciolovan, Laura Maria [Radiology Department, Gustave Roussy, Villejuif (France); Dunant, Ariane [Department of Statistics, Gustave Roussy, Villejuif (France); Vielh, Philippe [Department of Biopathology, Gustave Roussy, Villejuif (France); Mazouni, Chafika [Department of Surgery, Gustave Roussy, Villejuif (France); Delaloge, Suzette [Department of Oncology, Gustave Roussy, Villejuif (France); Dromain, Clarisse [Radiology Department, Gustave Roussy, Villejuif (France); Blidaru, Alexandru [Department of Surgery, Bucharest Institute of Oncology, Bucharest (Romania); Balleyguier, Corinne, E-mail: corinne.balleyguier@gustaveroussy.fr [Radiology Department, Gustave Roussy, Villejuif (France); UMR 8081, IR4M, Paris-Sud University, 91405 Orsay (France)

    2014-05-15

    Purpose: To determine the diagnostic performance of Acoustic Radiation Force Impulse (ARFI) Virtual Touch IQ shear wave elastography in the discrimination of benign and malignant breast lesions. Materials and methods: Conventional B-mode and elasticity imaging were used to evaluate 110 breast lesions. Elastographic assessment of breast tissue abnormalities was done using a shear wave based technique, Virtual Touch IQ (VTIQ), implemented on a Siemens Acuson S3000 ultrasound machine. Tissue mechanical properties were interpreted as two-dimensional qualitative and quantitative colour maps displaying relative shear wave velocity. Wave speed measurements in m/s were possible at operator defined regions of interest. The pathologic diagnosis was established on samples obtained by ultrasound guided core biopsy or fine needle aspiration. Results: BIRADS based B-mode evaluation of the 48 benign and 62 malignant lesions achieved 92% sensitivity and 62.5% specificity. Subsequently performed VTIQ elastography relying on visual interpretation of the colour overlay displaying relative shear wave velocities managed similar standalone diagnostic performance with 92% sensitivity and 64.6% specificity. Lesion and surrounding tissue shear wave speed values were calculated and a significant difference was found between the benign and malignant populations (Mann–Whitney U test, p < 0.0001). By selecting a lesion cut-off value of 3.31 m/s we achieved 80.4% sensitivity and 73% specificity. Applying this threshold only to BIRADS 4a masses, we reached overall levels of 92% sensitivity and 72.9% specificity. Conclusion: VTIQ qualitative and quantitative elastography has the potential to further characterise B-mode detected breast lesions, increasing specificity and reducing the number of unnecessary biopsies.

  11. Added value of Virtual Touch IQ shear wave elastography in the ultrasound assessment of breast lesions

    International Nuclear Information System (INIS)

    Ianculescu, Victor; Ciolovan, Laura Maria; Dunant, Ariane; Vielh, Philippe; Mazouni, Chafika; Delaloge, Suzette; Dromain, Clarisse; Blidaru, Alexandru; Balleyguier, Corinne

    2014-01-01

    Purpose: To determine the diagnostic performance of Acoustic Radiation Force Impulse (ARFI) Virtual Touch IQ shear wave elastography in the discrimination of benign and malignant breast lesions. Materials and methods: Conventional B-mode and elasticity imaging were used to evaluate 110 breast lesions. Elastographic assessment of breast tissue abnormalities was done using a shear wave based technique, Virtual Touch IQ (VTIQ), implemented on a Siemens Acuson S3000 ultrasound machine. Tissue mechanical properties were interpreted as two-dimensional qualitative and quantitative colour maps displaying relative shear wave velocity. Wave speed measurements in m/s were possible at operator defined regions of interest. The pathologic diagnosis was established on samples obtained by ultrasound guided core biopsy or fine needle aspiration. Results: BIRADS based B-mode evaluation of the 48 benign and 62 malignant lesions achieved 92% sensitivity and 62.5% specificity. Subsequently performed VTIQ elastography relying on visual interpretation of the colour overlay displaying relative shear wave velocities managed similar standalone diagnostic performance with 92% sensitivity and 64.6% specificity. Lesion and surrounding tissue shear wave speed values were calculated and a significant difference was found between the benign and malignant populations (Mann–Whitney U test, p < 0.0001). By selecting a lesion cut-off value of 3.31 m/s we achieved 80.4% sensitivity and 73% specificity. Applying this threshold only to BIRADS 4a masses, we reached overall levels of 92% sensitivity and 72.9% specificity. Conclusion: VTIQ qualitative and quantitative elastography has the potential to further characterise B-mode detected breast lesions, increasing specificity and reducing the number of unnecessary biopsies

  12. High-frequency ultrasound for intraoperative margin assessments in breast conservation surgery: a feasibility study

    International Nuclear Information System (INIS)

    Doyle, Timothy E; Neumayer, Leigh A; Factor, Rachel E; Ellefson, Christina L; Sorensen, Kristina M; Ambrose, Brady J; Goodrich, Jeffrey B; Hart, Vern P; Jensen, Scott C; Patel, Hemang

    2011-01-01

    In addition to breast imaging, ultrasound offers the potential for characterizing and distinguishing between benign and malignant breast tissues due to their different microstructures and material properties. The aim of this study was to determine if high-frequency ultrasound (20-80 MHz) can provide pathology sensitive measurements for the ex vivo detection of cancer in margins during breast conservation surgery. Ultrasonic tests were performed on resected margins and other tissues obtained from 17 patients, resulting in 34 specimens that were classified into 15 pathology categories. Pulse-echo and through-transmission measurements were acquired from a total of 57 sites on the specimens using two single-element 50-MHz transducers. Ultrasonic attenuation and sound speed were obtained from time-domain waveforms. The waveforms were further processed with fast Fourier transforms to provide ultrasonic spectra and cepstra. The ultrasonic measurements and pathology types were analyzed for correlations. The specimens were additionally re-classified into five pathology types to determine specificity and sensitivity values. The density of peaks in the ultrasonic spectra, a measure of spectral structure, showed significantly higher values for carcinomas and precancerous pathologies such as atypical ductal hyperplasia than for normal tissue. The slopes of the cepstra for non-malignant pathologies displayed significantly greater values that differentiated them from the normal and malignant tissues. The attenuation coefficients were sensitive to fat necrosis, fibroadenoma, and invasive lobular carcinoma. Specificities and sensitivities for differentiating pathologies from normal tissue were 100% and 86% for lobular carcinomas, 100% and 74% for ductal carcinomas, 80% and 82% for benign pathologies, and 80% and 100% for fat necrosis and adenomas. Specificities and sensitivities were also determined for differentiating each pathology type from the other four using a multivariate

  13. High-frequency ultrasound for intraoperative margin assessments in breast conservation surgery: a feasibility study

    Directory of Open Access Journals (Sweden)

    Hart Vern P

    2011-10-01

    Full Text Available Abstract Background In addition to breast imaging, ultrasound offers the potential for characterizing and distinguishing between benign and malignant breast tissues due to their different microstructures and material properties. The aim of this study was to determine if high-frequency ultrasound (20-80 MHz can provide pathology sensitive measurements for the ex vivo detection of cancer in margins during breast conservation surgery. Methods Ultrasonic tests were performed on resected margins and other tissues obtained from 17 patients, resulting in 34 specimens that were classified into 15 pathology categories. Pulse-echo and through-transmission measurements were acquired from a total of 57 sites on the specimens using two single-element 50-MHz transducers. Ultrasonic attenuation and sound speed were obtained from time-domain waveforms. The waveforms were further processed with fast Fourier transforms to provide ultrasonic spectra and cepstra. The ultrasonic measurements and pathology types were analyzed for correlations. The specimens were additionally re-classified into five pathology types to determine specificity and sensitivity values. Results The density of peaks in the ultrasonic spectra, a measure of spectral structure, showed significantly higher values for carcinomas and precancerous pathologies such as atypical ductal hyperplasia than for normal tissue. The slopes of the cepstra for non-malignant pathologies displayed significantly greater values that differentiated them from the normal and malignant tissues. The attenuation coefficients were sensitive to fat necrosis, fibroadenoma, and invasive lobular carcinoma. Specificities and sensitivities for differentiating pathologies from normal tissue were 100% and 86% for lobular carcinomas, 100% and 74% for ductal carcinomas, 80% and 82% for benign pathologies, and 80% and 100% for fat necrosis and adenomas. Specificities and sensitivities were also determined for differentiating each

  14. The Interobserver Variability and Diagnostic Performance of 3-Dimensional Breast Ultrasound

    International Nuclear Information System (INIS)

    Lyou, Chae Yeon; Kim, Sun Mi; Jang, Mi Jung; Kim, Sung Won; Kang, Eun Young; Park, So Yeon; Moon, Woo Kyung

    2011-01-01

    We wanted to evaluate the interobserver variability and diagnostic performance of 3-dimensional (3D) breast ultrasound (US) as compared with that of 2- dimensional (2D) US. We included 150 patients who received US-guided core biopsy and 3D US between June 2009 and April 2010. Three breast imaging radiologists analyzed the 2D and 3D US images using the Breast Imaging Reporting and Data System (BI-RADS) lexicon. The intra-observer agreement and inter-observer agreement were calculated. The sensitivity and specificity of 2D and 3D US were evaluated. The intra-observer agreement between 2D and 3D US was mostly slight or fair agreement. However, in terms of the final category, there was substantial agreement for all three radiologists. The inter-observer agreement of 3D US was similar to that of 2D US (moderate agreement for shape, orientation, circumscribed margin and boundary: fair agreement for indistinct margin, angular margin, microlobulated margin, echo pattern and final category). The sensitivity of 3D US for breast cancer was higher than that of 2D US for two radiologists (2D vs. 3D for reader 2: 55.8% vs. 61.5%, 2D vs. 3D for reader 3: 59.6% vs. 63.5%), and the specificity of 3D US was lower than that of 2D US for all the readers (2D vs. 3D for reader 1: 90.8% vs. 86.7%, 2D vs. 3D for reader 2: 90.8% vs. 87.8%, 2D vs. 3D for reader 3: 94.9% vs. 90.8%), but the difference was not significant (p ≥ 0.05). The interobserver variability and diagnostic performance of 3D breast US were similar to those of 2D US

  15. Management guide and classification of breast lesions by mammography and ultrasound

    International Nuclear Information System (INIS)

    Carballo Garron, Victor

    2011-01-01

    The Servicio de Radiologia at the Hospital Calderon Guardia has a new ultrasound consultation, which is exclusive to the breast cancer screening and management of breast pathology, as an adjunct to mammography studies performed at the service. A guide to standardize mammographic reporting is offered on the center, the same nomenclature and classification system of standardized mammographic findings are used, also, the management of pathological findings images, based on the lexicon of the fourth edition of the data system and reporting breast image, or BI-RADS for its acronym in English, created in 2003 by the American College of Radiology. So same the terminology and systematic of the mammography report are standardized, injuries are categorized by establishing the degree of suspicion, and a recommendation is assigned on the attitude to take in each case, which represents a diagnostic tool that should be knowledge and used not only radiology staff, if not all the doctors who are related to the prevention, diagnosis and management, both medical and surgical pathology of the breast. The new BI-RADS recommends a joint valuation of all the techniques to assign a unique category and final recommendation. The preparation and use of management guidelines, specific to this service, breast pathology based on BI-RADS system benefits the patient, a early diagnosis is provided and agile handling of a disease. On the other hand, at the institutional level, the creation of such rules is beneficial because it allows the optimization of tests and procedures, leading to a reduction of cost and decreased waiting lists. These guidelines will be used by the radiology staff of Hospital Calderon Guardia at time of preparing written reports and when give the recommendations to both conservative handling as in the surgical management. (author) [es

  16. Automated breast volume scanner (ABVS) in assessing breast cancer size. A comparison with conventional ultrasound and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Girometti, Rossano; Zanotel, Martina; Londero, Viviana; Linda, Anna; Lorenzon, Michele; Zuiani, Chiara [University of Udine, Azienda Sanitaria Universitaria Integrata di Udine, Institute of Radiology, Department of Medicine, Udine (Italy)

    2018-03-15

    To compare automated breast volume scanner (ABVS), ultrasound (US) and MRI in measuring breast cancer size, and evaluate the agreement between ABVS and US in assessing lesion location and sonographic features. We retrospectively included 98 women with 100 index cancers who had undergone US and ABVS followed by 1.5T MRI. Images were interpreted by a pool of readers reporting lesion size, location and breast imaging reporting and data system (BI-RADS) features. Bland-Altman analysis (with logarithmic data transformation), intraclass correlation coefficient (ICC) and Cohen's kappa statistic were used for statistical analysis. MRI showed the best absolute agreement with histology in measuring cancer size (ICC 0.93), with LOA comparable to those of ABVS (0.63-1.99 vs. 0.52-1.73, respectively). Though ABVS and US had highly concordant measurements (ICC 0.95), ABVS showed better agreement with histology (LOA 0.52-1.73 vs. 0.45-1.86, respectively), corresponding to a higher ICC (0.85 vs. 0.75, respectively). Except for posterior features (k=0.39), the agreement between US and ABVS in attributing site and BI-RADS features ranged from substantial to almost perfect (k=0.68-0.85). ABVS performs better than US and approaches MRI in predicting breast cancer size. ABVS performs comparably to US in sonographic assessment of lesions. (orig.)

  17. Vacuum mammotomy under ultrasound guidance

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Pawlik, T.; Aniol, J.; Herman, K.; Skotnicki, P.

    2007-01-01

    Breast ultrasound is a non-invasive method of breast examination. You can use it also for fine needle biopsy, core needle biopsy, vacuum mammotomy and for placing the '' wire '' before open surgical biopsy. 106 patients (105 women and 1 man) aged 20-71 years (mean age 46.9) were treated in Cancer Institute in Cracow by vacuum mammotomy under ultrasound guidance. The lesions found in ultrasonography were divided into three groups: benign lesions (BI RADS II), ambiguous lesions (BI RADS 0, III and IVa), and suspicious lesions (BI RADS IV B, IV C and V). Then lesions were qualified to vacuum mammotomy. According to USG, fibroadenoma or '' fibroadenoma-like '' lesions were found in 75 women, in 6 women complicated cysts, in 6 women cyst with dense fluid (to differentiate with FA), and in 19 patients undefined lesions. Fibroadenoma was confirmed in histopathology in 74% patients among patients with fibroadenoma or '' fibroadenoma-like '' lesions in ultrasound (in others also benign lesions were found). Among lesions undefined after ultrasound examination (total 27 patients) cancer was confirmed in 6 % (DCIS and IDC). In 6 patients with complicated cysts in ultrasound examination, histopathology confirmed fibroadenoma in 4 women, an intraductal lesion in 1 woman and inflamatory process in 1 woman. Also in 6 women with a dense cyst or fibroadenoma seen in ultrasound, histopathology confirmed fibroadenoma in 3 women and fibrosclerosis in 3 women. Any breast lesions undefined or suspicious after ultrasound examination should be verified. The method of verification or kind of operation of the whole lesion (vacuum mammotomy or '' wire '') depends on many factors, for example: lesion localization; lesion size; BI RADS category. (author)

  18. Supplementation of beef cattle grazing Brachiariabrizantha during the dry and rainy seasons: performance and carcass ultrasound prediction

    Directory of Open Access Journals (Sweden)

    Geisi Loures Guerra

    2016-10-01

    Full Text Available The aim of this study was to evaluate the influence of genetic group, sex and level of protein-energy supplementation on the performance and carcass traitsultrasound prediction of weaned calves Nellore and crossbred animals ½ Nellore x ½ Aberdeen Angus. A completely randomized design in a factorial 2x2x2, were used, with two levels of protein-energy supplementation, two sex and two genetic groups. Fifty-six animals were used (28 Nellore and 28 crossbred ½ Nellore x ½ Aberdeen Angus, equally divided between males and females, maintained on grazing Brachiariabrizanthacv. Marandu and evaluated in three experimental periods: period 1 = protein-energy supplementation in the dry season; period 2 = protein-energy supplementation during the rainy season; period 3 = only mineral supplementation. In the dry season, they were supplemented with levels of 0.5 and 1% of body weight (BW and in the rainy season with 0 and 1% BW. Dry matter intake (kg day-1, % BW, g kgBW0.75-1 was estimated. In vivo ultrasound measurements of carcass were: loin eye area (LEA, fat thickness (FT and rump fat thickness (RFT. There was influence of genetic group and protein-energy supplementation levels on average daily gain (ADG of animals in period 1 and 2 (P < 0.05. Sex affected the ADG only in period 2, and the males had 754 gday-1 and females, 582 g day-1. There was no interaction of genetic group x sex x supplementation level. At the end of the experimental period (end of period 3, it was found that male animals and crossbred animals ½ Nellore x ½ Aberdeen Angus had higher ADG (716 and 748 g day-1, respectively. The values of dry matter intake (DMI were influenced by genetic group and sex, in all periods, verifying highest intake in crossbred animals ½ Nellore x ½ Aberdeen Angus, with better feed conversion for crossbred animals. Regarding ultrasound measurements taken on the carcass, the influence of sex on FT and RFT, it was observed, and the males showed higher

  19. Does shear wave ultrasound independently predict axillary lymph node metastasis in women with invasive breast cancer?

    Science.gov (United States)

    Evans, Andrew; Rauchhaus, Petra; Whelehan, Patsy; Thomson, Kim; Purdie, Colin A; Jordan, Lee B; Michie, Caroline O; Thompson, Alastair; Vinnicombe, Sarah

    2014-01-01

    Shear wave elastography (SWE) shows promise as an adjunct to greyscale ultrasound examination in assessing breast masses. In breast cancer, higher lesion stiffness on SWE has been shown to be associated with features of poor prognosis. The purpose of this study was to assess whether lesion stiffness at SWE is an independent predictor of lymph node involvement. Patients with invasive breast cancer treated by primary surgery, who had undergone SWE examination were eligible. Data were retrospectively analysed from 396 consecutive patients. The mean stiffness values were obtained using the Aixplorer® ultrasound machine from SuperSonic Imagine Ltd. Measurements were taken from a region of interest positioned over the stiffest part of the abnormality. The average of the mean stiffness value obtained from each of two orthogonal image planes was used for analysis. Associations between lymph node involvement and mean lesion stiffness, invasive cancer size, histologic grade, tumour type, ER expression, HER-2 status and vascular invasion were assessed using univariate and multivariate logistic regression. At univariate analysis, invasive size, histologic grade, HER-2 status, vascular invasion, tumour type and mean stiffness were significantly associated with nodal involvement. Nodal involvement rates ranged from 7 % for tumours with mean stiffness 150 kPa. At multivariate analysis, invasive size, tumour type, vascular invasion, and mean stiffness maintained independent significance. Mean stiffness at SWE is an independent predictor of lymph node metastasis and thus can confer prognostic information additional to that provided by conventional preoperative tumour assessment and staging.

  20. CLINICOPATHOLOGICAL FACTORS ASSOCIATED WITH POSITIVE PREOPERATIVE AXILLARY ULTRASOUND SCANNING IN BREAST CANCER PATIENTS

    Directory of Open Access Journals (Sweden)

    Lona Jalini

    2016-01-01

    Full Text Available Background: Axillary lymph node status is the most important breast cancer prognostic factor. Preoperative axillary ultrasound examination (PAUS is used to triage patients for sentinel lymph node biopsy (SLNB or axillary lymph node dissection (ALND. We assessed the detection rate of lymph node metastases by PAUS in a screening unit and evaluated associations between clinicopathological factors and PAUS positivity. Patients and Methods: This was a single-centre retrospective analysis of data extracted from a hospital breast cancer database and clinical records. Clinical, radiological, and pathological and prognostic indices were compared between PAUS-positive and PAUS-negative patients subsequently found to have lymph node metastases on histopathological analysis. Results: Two hundred and two patients were eligible for analysis. 50.5% of lymph node-positive patients were correctly identified as PAUS positive. Patients with PAUS-positive lymph nodes had less favorable disease characteristics, namely clinically palpable lymph nodes, higher Nottingham prognostic (NPI index, high lymph node burden according to the European Society of Medical Oncology (ESMO group classification, and larger, grade 3 tumors with lymphovascular invasion and extranodal spread. Moreover, PAUS-positive patients had more macrometastases and lymph node involvement than PAUS-negative patients. Conclusion: PAUS-positive patients and PAUS-negative (SLNB-positive patients have different clinicopathological characteristics. The presence of LVI, extranodal spread, grade 3 histology, or large tumors with poor prognostic indices in PAUS-negative patients should be regarded with caution and perhaps prompt second-look ultrasound examination.

  1. Effect of Calcifications on Breast Ultrasound Shear Wave Elastography: An Investigational Study.

    Science.gov (United States)

    Gregory, Adriana; Mehrmohammadi, Mohammad; Denis, Max; Bayat, Mahdi; Stan, Daniela L; Fatemi, Mostafa; Alizad, Azra

    2015-01-01

    To investigate the effects of macrocalcifications and clustered microcalcifications associated with benign breast masses on shear wave elastography (SWE). SuperSonic Imagine (SSI) and comb-push ultrasound shear elastography (CUSE) were performed on three sets of phantoms to investigate how calcifications of different sizes and distributions influence measured elasticity. To demonstrate the effect in vivo, three female patients with benign breast masses associated with mammographically-identified calcifications were evaluated by CUSE. Apparent maximum elasticity (Emax) estimates resulting from individual macrocalcifications (with diameters of 2mm, 3mm, 5mm, 6mm, 9mm, 11mm, and 15mm) showed values over 50 kPa for all cases, which represents more than 100% increase over background (~21kPa). We considered a 2cm-diameter circular region of interest for all phantom experiments. Mean elasticity (Emean) values varied from 26 kPa to 73 kPa, depending on the macrocalcification size. Highly dense clusters of microcalcifications showed higher Emax values than clusters of microcalcification with low concentrations, but the difference in Emean values was not significant. Our results demonstrate that the presence of large isolated macrocalcifications and highly concentrated clusters of microcalcifications can introduce areas with apparent high elasticity in SWE. Considering that benign breast masses normally have significantly lower elasticity values than malignant tumors, such areas with high elasticity appearing due to presence of calcification in benign breast masses may lead to misdiagnosis.

  2. Effect of Calcifications on Breast Ultrasound Shear Wave Elastography: An Investigational Study.

    Directory of Open Access Journals (Sweden)

    Adriana Gregory

    Full Text Available To investigate the effects of macrocalcifications and clustered microcalcifications associated with benign breast masses on shear wave elastography (SWE.SuperSonic Imagine (SSI and comb-push ultrasound shear elastography (CUSE were performed on three sets of phantoms to investigate how calcifications of different sizes and distributions influence measured elasticity. To demonstrate the effect in vivo, three female patients with benign breast masses associated with mammographically-identified calcifications were evaluated by CUSE.Apparent maximum elasticity (Emax estimates resulting from individual macrocalcifications (with diameters of 2mm, 3mm, 5mm, 6mm, 9mm, 11mm, and 15mm showed values over 50 kPa for all cases, which represents more than 100% increase over background (~21kPa. We considered a 2cm-diameter circular region of interest for all phantom experiments. Mean elasticity (Emean values varied from 26 kPa to 73 kPa, depending on the macrocalcification size. Highly dense clusters of microcalcifications showed higher Emax values than clusters of microcalcification with low concentrations, but the difference in Emean values was not significant.Our results demonstrate that the presence of large isolated macrocalcifications and highly concentrated clusters of microcalcifications can introduce areas with apparent high elasticity in SWE. Considering that benign breast masses normally have significantly lower elasticity values than malignant tumors, such areas with high elasticity appearing due to presence of calcification in benign breast masses may lead to misdiagnosis.

  3. Impact on Clinical Management of After-Hours Emergent or Urgent Breast Ultrasonography in Patients with Clinically Suspected Breast Abscesses

    Directory of Open Access Journals (Sweden)

    Tanya W. Moseley

    2018-02-01

    Full Text Available Newly diagnosed breast abscesses are generally treated as a medical emergency that may necessitate immediate interventional treatment. At our institution, there is no in-house after-hours coverage for breast ultrasonography. We could find no peer-reviewed studies on the cost-effectiveness or clinical management impact of on-call ultrasound technologist coverage for imaging of breast abscesses. The purposes of this study were to determine the incidence of breast abscess in patients with clinical findings highly suggestive of abscess, identify clinical factors associated with breast abscess in such patients, and determine the impact of after-hours emergent or urgent breast ultrasonography on the clinical management of breast abscesses in both outpatients and inpatients. We retrospectively reviewed 100 after-hours breast ultrasound studies performed at our tertiary care center from 2011 to 2015 for evaluation of a suspected breast abscess. Only 26% of our patients with clinically suspected abscess ultimately had a confirmed abscess. Factors associated with breast abscess were a palpable abnormality and a history of breast surgery within the eight weeks before presentation. After-hours diagnosis of an abscess was associated with after-hours clinical intervention. Of the 74 patients in whom after-hours ultrasound imaging showed no evidence of abscess, only three patients underwent after-hours drainage. Our findings support overnight and weekend breast ultrasound coverage in large tertiary care centers.

  4. Impact on Clinical Management of After-Hours Emergent or Urgent Breast Ultrasonography in Patients with Clinically Suspected Breast Abscesses

    Science.gov (United States)

    Moseley, Tanya W.; Stanley, Ashley; Wei, Wei; Parikh, Jay R.

    2018-01-01

    Newly diagnosed breast abscesses are generally treated as a medical emergency that may necessitate immediate interventional treatment. At our institution, there is no in-house after-hours coverage for breast ultrasonography. We could find no peer-reviewed studies on the cost-effectiveness or clinical management impact of on-call ultrasound technologist coverage for imaging of breast abscesses. The purposes of this study were to determine the incidence of breast abscess in patients with clinical findings highly suggestive of abscess, identify clinical factors associated with breast abscess in such patients, and determine the impact of after-hours emergent or urgent breast ultrasonography on the clinical management of breast abscesses in both outpatients and inpatients. We retrospectively reviewed 100 after-hours breast ultrasound studies performed at our tertiary care center from 2011 to 2015 for evaluation of a suspected breast abscess. Only 26% of our patients with clinically suspected abscess ultimately had a confirmed abscess. Factors associated with breast abscess were a palpable abnormality and a history of breast surgery within the eight weeks before presentation. After-hours diagnosis of an abscess was associated with after-hours clinical intervention. Of the 74 patients in whom after-hours ultrasound imaging showed no evidence of abscess, only three patients underwent after-hours drainage. Our findings support overnight and weekend breast ultrasound coverage in large tertiary care centers. PMID:29473859

  5. Impact on Clinical Management of After-Hours Emergent or Urgent Breast Ultrasonography in Patients with Clinically Suspected Breast Abscesses.

    Science.gov (United States)

    Moseley, Tanya W; Stanley, Ashley; Wei, Wei; Parikh, Jay R

    2018-02-23

    Newly diagnosed breast abscesses are generally treated as a medical emergency that may necessitate immediate interventional treatment. At our institution, there is no in-house after-hours coverage for breast ultrasonography. We could find no peer-reviewed studies on the cost-effectiveness or clinical management impact of on-call ultrasound technologist coverage for imaging of breast abscesses. The purposes of this study were to determine the incidence of breast abscess in patients with clinical findings highly suggestive of abscess, identify clinical factors associated with breast abscess in such patients, and determine the impact of after-hours emergent or urgent breast ultrasonography on the clinical management of breast abscesses in both outpatients and inpatients. We retrospectively reviewed 100 after-hours breast ultrasound studies performed at our tertiary care center from 2011 to 2015 for evaluation of a suspected breast abscess. Only 26% of our patients with clinically suspected abscess ultimately had a confirmed abscess. Factors associated with breast abscess were a palpable abnormality and a history of breast surgery within the eight weeks before presentation. After-hours diagnosis of an abscess was associated with after-hours clinical intervention. Of the 74 patients in whom after-hours ultrasound imaging showed no evidence of abscess, only three patients underwent after-hours drainage. Our findings support overnight and weekend breast ultrasound coverage in large tertiary care centers.

  6. A deep learning framework for supporting the classification of breast lesions in ultrasound images

    Science.gov (United States)

    Han, Seokmin; Kang, Ho-Kyung; Jeong, Ja-Yeon; Park, Moon-Ho; Kim, Wonsik; Bang, Won-Chul; Seong, Yeong-Kyeong

    2017-10-01

    In this research, we exploited the deep learning framework to differentiate the distinctive types of lesions and nodules in breast acquired with ultrasound imaging. A biopsy-proven benchmarking dataset was built from 5151 patients cases containing a total of 7408 ultrasound breast images, representative of semi-automatically segmented lesions associated with masses. The dataset comprised 4254 benign and 3154 malignant lesions. The developed method includes histogram equalization, image cropping and margin augmentation. The GoogLeNet convolutionary neural network was trained to the database to differentiate benign and malignant tumors. The networks were trained on the data with augmentation and the data without augmentation. Both of them showed an area under the curve of over 0.9. The networks showed an accuracy of about 0.9 (90%), a sensitivity of 0.86 and a specificity of 0.96. Although target regions of interest (ROIs) were selected by radiologists, meaning that radiologists still have to point out the location of the ROI, the classification of malignant lesions showed promising results. If this method is used by radiologists in clinical situations it can classify malignant lesions in a short time and support the diagnosis of radiologists in discriminating malignant lesions. Therefore, the proposed method can work in tandem with human radiologists to improve performance, which is a fundamental purpose of computer-aided diagnosis.

  7. Evaluation of breast lesions by contrast enhanced ultrasound: Qualitative and quantitative analysis

    International Nuclear Information System (INIS)

    Wan Caifeng; Du Jing; Fang Hua; Li Fenghua; Wang Lin

    2012-01-01

    Objective: To evaluate and compare the diagnostic performance of qualitative, quantitative and combined analysis for characterization of breast lesions in contrast enhanced ultrasound (CEUS), with histological results used as the reference standard. Methods: Ninety-one patients with 91 breast lesions BI-RADS 3–5 at US or mammography underwent CEUS. All lesions underwent qualitative and quantitative enhancement evaluation. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of different analytical method for discrimination between benign and malignant breast lesions. Results: Histopathologic analysis of the 91 lesions revealed 44 benign and 47 malignant. For qualitative analysis, benign and malignant lesions differ significantly in enhancement patterns (p z1 ), 0.768 (A z2 ) and 0.926(A z3 ) respectively. The values of A z1 and A z3 were significantly higher than that for A z2 (p = 0.024 and p = 0.008, respectively). But there was no significant difference between the values of A z1 and A z3 (p = 0.625). Conclusions: The diagnostic performance of qualitative and combined analysis was significantly higher than that for quantitative analysis. Although quantitative analysis has the potential to differentiate benign from malignant lesions, it has not yet improved the final diagnostic accuracy.

  8. Incidental enhancing lesions found on preoperative breast MRI: management and role of second-look ultrasound.

    Science.gov (United States)

    Luciani, M L; Pediconi, F; Telesca, M; Vasselli, F; Casali, V; Miglio, E; Passariello, R; Catalano, C

    2011-09-01

    This study prospectively assessed second-look ultrasound (US) for the evaluation of incidental enhancing lesions identified on preoperative breast magnetic resonance imaging (MRI). Between 2004 and 2007, 182 patients with malignant breast lesions detected on US and/or X-ray mammography and confirmed by cytology/histology underwent preoperative breast contrast-enhanced (CE)-MRI. Patients with incidental lesions on breast MRI underwent second-look high-resolution US directed at the site of the incidental finding. Diagnosis of incidental lesions was based on biopsy or 24-month follow-up. Breast MRI detected 55 additional lesions in 46/182 (25.2%) patients. Forty-two of 55 (76.3%) lesions were detected on second-look US in 38/46 (82.6%) patients. Malignancy was confirmed for 24/42 (57.1%) correlate lesions compared with 7/13 (53.8%) noncorrelate lesions. Second-look US depicted 8/9 (88.8%) Breast Imaging Reporting and Data System (BI-RADS) 5, 16/22 (72.7%) BI-RADS 4 and 18/24 (75%) BI-RADS 3 lesions. Sensitivity, specificity, accuracy and positive and negative predictive values for lesion detection/diagnosis was 100%, 88.9%, 94.6%, 90.3% and 100% for MRI and 64.3%, 70.4%, 67.3%, 69.2% and 65.5% for second-look US. Improved performance for US was obtained when masslike lesions only were considered. Second-look US is a confirmatory method for incidental findings on breast MRI, particularly for mass-like lesions.

  9. Improved cancer detection in automated breast ultrasound by radiologists using Computer Aided Detection

    International Nuclear Information System (INIS)

    Zelst, J.C.M. van; Tan, T.; Platel, B.; Jong, M. de; Steenbakkers, A.; Mourits, M.; Grivegnee, A.; Borelli, C.; Karssemeijer, N.; Mann, R.M.

    2017-01-01

    Objective: To investigate the effect of dedicated Computer Aided Detection (CAD) software for automated breast ultrasound (ABUS) on the performance of radiologists screening for breast cancer. Methods: 90 ABUS views of 90 patients were randomly selected from a multi-institutional archive of cases collected between 2010 and 2013. This dataset included normal cases (n = 40) with >1 year of follow up, benign (n = 30) lesions that were either biopsied or remained stable, and malignant lesions (n = 20). Six readers evaluated all cases with and without CAD in two sessions. CAD-software included conventional CAD-marks and an intelligent minimum intensity projection of the breast tissue. Readers reported using a likelihood-of-malignancy scale from 0 to 100. Alternative free-response ROC analysis was used to measure the performance. Results: Without CAD, the average area-under-the-curve (AUC) of the readers was 0.77 and significantly improved with CAD to 0.84 (p = 0.001). Sensitivity of all readers improved (range 5.2–10.6%) by using CAD but specificity decreased in four out of six readers (range 1.4–5.7%). No significant difference was observed in the AUC between experienced radiologists and residents both with and without CAD. Conclusions: Dedicated CAD-software for ABUS has the potential to improve the cancer detection rates of radiologists screening for breast cancer.

  10. Improved cancer detection in automated breast ultrasound by radiologists using Computer Aided Detection

    Energy Technology Data Exchange (ETDEWEB)

    Zelst, J.C.M. van, E-mail: Jan.vanZelst@radboudumc.nl [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Tan, T.; Platel, B. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Jong, M. de [Jeroen Bosch Medical Centre, Department of Radiology, ‘s-Hertogenbosch (Netherlands); Steenbakkers, A. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands); Mourits, M. [Jeroen Bosch Medical Centre, Department of Radiology, ‘s-Hertogenbosch (Netherlands); Grivegnee, A. [Jules Bordet Institute, Department of Radiology, Brussels (Belgium); Borelli, C. [Catholic University of the Sacred Heart, Department of Radiological Sciences, Rome (Italy); Karssemeijer, N.; Mann, R.M. [Radboud University Medical Center, Department of Radiology and Nuclear Medicine, Nijmegen (Netherlands)

    2017-04-15

    Objective: To investigate the effect of dedicated Computer Aided Detection (CAD) software for automated breast ultrasound (ABUS) on the performance of radiologists screening for breast cancer. Methods: 90 ABUS views of 90 patients were randomly selected from a multi-institutional archive of cases collected between 2010 and 2013. This dataset included normal cases (n = 40) with >1 year of follow up, benign (n = 30) lesions that were either biopsied or remained stable, and malignant lesions (n = 20). Six readers evaluated all cases with and without CAD in two sessions. CAD-software included conventional CAD-marks and an intelligent minimum intensity projection of the breast tissue. Readers reported using a likelihood-of-malignancy scale from 0 to 100. Alternative free-response ROC analysis was used to measure the performance. Results: Without CAD, the average area-under-the-curve (AUC) of the readers was 0.77 and significantly improved with CAD to 0.84 (p = 0.001). Sensitivity of all readers improved (range 5.2–10.6%) by using CAD but specificity decreased in four out of six readers (range 1.4–5.7%). No significant difference was observed in the AUC between experienced radiologists and residents both with and without CAD. Conclusions: Dedicated CAD-software for ABUS has the potential to improve the cancer detection rates of radiologists screening for breast cancer.

  11. The utility of breast cone-beam computed tomography, ultrasound, and digital mammography for detecting malignant breast tumors: A prospective study with 212 patients.

    Science.gov (United States)

    He, Ni; Wu, Yao-Pan; Kong, Yanan; Lv, Ning; Huang, Zhi-Mei; Li, Sheng; Wang, Yue; Geng, Zhi-Jun; Wu, Pei-Hong; Wei, Wei-Dong

    2016-02-01

    Breast cone-beam computed tomography (BCBCT) is a flat-panel detector (FPD)-based X-ray imaging system that provides high-quality images of the breast. The purpose of this study was to investigate the ability to detect breast abnormalities using non-contrast BCBCT and contrast-enhanced BCBCT (BCBCT and CE-BCBCT) compared to ultrasound (US) and digital mammography (MG). A prospective study was performed from May 2012 to August 2014. Ninety-two patients (172 lesions) underwent BCBCT alone, and 120 patients (270 lesions) underwent BCBCT and CE-BCBCT, all the patients underwent US and MG. Cancer diagnosis was confirmed pathologically in 102 patients (110 lesions). BCBCT identified 97 of 110 malignant lesions, whereas 93 malignant lesions were identified using MG and US. The areas under the receiver operating curves (AUCs) for breast cancer diagnosis were 0.861 (BCBCT), 0.856 (US), and 0.829 (MG). CE-BCBCT improved cancer diagnostic sensitivity by 20.3% (78.4-98.7%). The AUC values were 0.869 (CE-BCBCT), 0.846 (BCBCT), 0.834 (US), and 0.782 (MG). In this preliminary study, BCBCT was found to accurately identify malignant breast lesions in a diagnostic setting. CE-BCBCT provided additional information and improved cancer diagnosis in style c or d breasts compared to the use of BCBCT, US, or MG alone. Copyright © 2015. Published by Elsevier Ireland Ltd.

  12. The effect of formula versus breast feeding and exogenous vitamin K1 supplementation on circulating levels of vitamin K1 and vitamin K-dependent clotting factors in newborns

    NARCIS (Netherlands)

    Hogenbirk, K.; Peters, M.; Bouman, P.; Sturk, A.; Büller, H. A.

    1993-01-01

    The influence of breast or formula feeding together with that of a single supplementation of vitamin K1 at birth, on the vitamin K1 level and vitamin K-dependent clotting factors were studied in 65 breast and 15 formula fed infants. All breast fed newborns without supplementation (n = 25) had very

  13. Agreement Between an Automated Volume Breast Scanner and Handheld Ultrasound for Diagnostic Breast Examinations.

    Science.gov (United States)

    Barr, Richard G; DeVita, Robert; Destounis, Stamatia; Manzoni, Federica; De Silvestri, Annalisa; Tinelli, Carmine

    2017-10-01

    To compare the agreement and interobserver variability of diagnostic handheld ultrasound (US) and a single volume on an automated breast volume scanner (ABVS) and to determine whether there was a significant difference if the ABVS was used by a sonographer or mammographic technologist. Ninety patients scheduled for diagnostic US examinations were randomized to either handheld US or the ABVS first. The AVBS was randomized between a sonographer and a mammographic technologist performing the study. The studies were blinded, randomized, and read by 2 radiologists. The lesion with the highest Breast Imaging Reporting and Data System (BI-RADS) score was used in the analysis. Final diagnoses were made by core biopsy or follow-up for 2 years. Lesions included 9 malignant and 81 benign. The 90 patients had a mean age ± SD of 53.1 ± 16.3 years. The κ value for agreement between the ABVS and handheld US was 0.831 (95% confidence interval, 0.744-0.925), whereas the global agreement for a 7-point BI-RADS score was 0.488 (0.372-0.560). The agreement between the ABVS and handheld US was nearly the same when the ABVS was used by a mammographic technologist (κ = 0.858 [0.723-0.963]) or sonographer (κ = 0.803 [0.596-1.000]; P = .47). The areas under the receiver operating characteristic curves for characterization by the ABVS were 0.91 (0.84-0.96) for reader 1 and 0.91 (0.83-0.96) for reader 2; those for handheld US were 0.91 (0.84-0.96) for reader 1 and 0.83 (0.74-0.90) for reader 2, with no statistical difference. The agreement based on pathologic images was κ = 0.831 (0.718-0.944); for handheld US, κ = 0.795 (0.623-0.967); and for the AVBS, κ = 0.869 (0.725-1.000). Performing a single-view diagnostic ABVS examination has good agreement with a handheld diagnostic US workup. There is no difference if the ABVS is used by a sonographer or mammographic technologist. © 2017 by the American Institute of Ultrasound in Medicine.

  14. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  15. Pseudomonal breast infection

    Science.gov (United States)

    Rastall, S; Catchpole, C; Bright-Thomas, R; Thrush, S

    2010-01-01

    Breast infection and breast sepsis secondary to Pseudomonas aeruginosa is uncommon. We report two cases of pseudomonal breast infection leading to septic shock and abscess formation in women with non-responding breast infection. The management of breast infection is broad-spectrum antibiotics and ultrasound with aspiration of any collection. To treat breast infection effectively, the causative organism must be isolated to enable appropriate antibiotic therapy. PMID:20412664

  16. Comparison of the diagnostic value of FDG-PET/CT and axillary ultrasound for the detection of lymph node metastases in breast cancer patients

    International Nuclear Information System (INIS)

    Riegger, Carolin; Heusner, Till A.; Koeninger, Angela; Kimmig, Rainer; Hartung, Verena; Bockisch, Andreas; Otterbach, Friedrich; Forsting, Michael; Antoch, Gerald

    2012-01-01

    Background. FDG-PET/CT is increasingly being used for breast cancer staging. Its diagnostic accuracy in comparison to ultrasound as the standard non-invasive imaging modality for the evaluation of axillary lymph nodes has yet not been evaluated. Purpose. To retrospectively compare the diagnostic value of full-dose, intravenously contrast-enhanced FDG-PET/CT and ultrasound for the detection of lymph node metastases in breast cancer patients. Material and Methods. Ninety patients (one patient with a bilateral carcinoma) (89 women, one man; mean age, 55.5 ± 16.6 years) suffering from primary breast cancer underwent whole-body FDG-PET/CT and axillary ultrasound. The ipsilateral axillary fossa (n = 91) was evaluated for metastatic spread. The sensitivity, specificity, the positive predictive value (PPV), negative predictive value (NPV), and accuracy of both methods were calculated. The sensitivity and accuracy were statistically compared using the McNemar Test (P <0.05). Analyses were made on a patient basis. The number of patients with extra-axillary locoregional lymph node metastases exclusively detected by FDG-PET/CT was evaluated. For axillary lymph node metastases histopathology served as the reference standard. Results. The sensitivity, specificity, PPV, NPV, and accuracy of FDG-PET/CT for the detection of axillary lymph node metastases were 54%, 89%, 77%, 74%, and 75%, respectively. For ultrasound it was 38%, 78%, 54%, 65%, and 62%, respectively. FDG-PET/CT was significantly more accurate than ultrasound for the detection of axillary lymph node metastases (P = 0.019). There was no statistically significant difference between the sensitivity of both modalities (P = 0.0578). FDG-PET/CT detected extra-axillary locoregional lymph node metastases in seven patients (8%) that had not been detected by another imaging modality. Conclusion. Though more accurate compared to ultrasound for evaluating the axillary lymph node status FDG-PET/CT is only as sensitive as

  17. Incremental Cancer Detection of Locoregional Restaging with Diagnostic Mammography Combined with Whole-Breast and Regional Nodal Ultrasound in Women with Newly Diagnosed Breast Cancer.

    Science.gov (United States)

    Candelaria, Rosalind P; Huang, Monica L; Adrada, Beatriz E; Bassett, Roland; Hunt, Kelly K; Kuerer, Henry M; Smith, Benjamin D; Chavez-MacGregor, Mariana; Yang, Wei Tse

    2017-02-01

    This study aims to determine if locoregional restaging with diagnostic mammography and ultrasound (US) of the whole breast and regional nodes performed for quality assurance in women with newly diagnosed breast cancer who were referred to a tertiary care center yields incremental cancer detection. An institutional review board-approved retrospective, single-institution database review was performed on the first 1000 women referred to our center in 2010 with a provisional breast cancer diagnosis. Locoregional restaging consisted of diagnostic full-field digital mammography combined with US of the whole breast and regional nodal basins. Bilateral whole-breast US was performed in women with contralateral mammographic abnormality or had heterogeneously or extremely dense parenchyma. Demographic, clinical, and pathologic factors were analyzed. Final analyses included 401 women. Of the 401 women, 138 (34%) did not have their outside images available for review upon referral. The median age was 54 years (range 21-92); the median tumor size was 2.9 cm (range 0.6-18.0) for women whose disease was upstaged and 2.2 cm (range 0.4-15.0) for women whose disease was not upstaged. Incremental cancer detection rates were 15.5% (62 of 401) in the ipsilateral breast and 3.9% (6 of 154) in the contralateral breast (P breast and regional nodal US that is performed for standardization of the imaging workup for newly diagnosed breast cancer patients can reduce underestimation of disease burden and impact therapeutic planning. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  18. Breast Cancer in Men

    Science.gov (United States)

    ... ultrasound or a breast MRI cannot rule out breast cancer then you will need a biopsy to confirm diagnosis. If diagnosed When first diagnosed with breast cancer, many men are in shock. After all, ...

  19. The Influence of Chlorella and Its Hot Water Extract Supplementation on Quality of Life in Patients with Breast Cancer

    Directory of Open Access Journals (Sweden)

    Naoto Noguchi

    2014-01-01

    Full Text Available A self-control, randomized, and open-label clinical trial was performed to test the effects of the unicellular green algae Chlorella and hot water extract supplementation on quality of life (QOL in patients with breast cancer. Forty-five female patients with breast cancer who were living at home and not hospitalized were randomly assigned to 3 groups receiving vitamin mix tablet (control, Chlorella granules (test food-1, or Chlorella extract drink (test food-2 daily for one month. The Functional Assessment of Cancer Therapy-Breast (FACT-B, the Izumo scale for abdominal symptom-specific QOL, and a narrative-form questionnaire were used to determine outcomes. Data of thirty-six subjects were included for final analysis. FACT-B scores at presupplementation found no significant group differences in all subscales. Scores on the breast cancer subscale in the Chlorella granule group significantly increased during the supplementation period (P=0.042. Fifty percent of the Chlorella extract group reported positive effects by the test food such as reduction of fatigue and improvements of dry skin (P<0.01 versus control group. The findings suggested the beneficial effects of Chlorella on breast cancer-related QOL and of Chlorella extract on vitality status in breast cancer patients. These findings need to be confirmed in a larger study.

  20. Automatic ultrasound image enhancement for 2D semi-automatic breast-lesion segmentation

    Science.gov (United States)

    Lu, Kongkuo; Hall, Christopher S.

    2014-03-01

    Breast cancer is the fastest growing cancer, accounting for 29%, of new cases in 2012, and second leading cause of cancer death among women in the United States and worldwide. Ultrasound (US) has been used as an indispensable tool for breast cancer detection/diagnosis and treatment. In computer-aided assistance, lesion segmentation is a preliminary but vital step, but the task is quite challenging in US images, due to imaging artifacts that complicate detection and measurement of the suspect lesions. The lesions usually present with poor boundary features and vary significantly in size, shape, and intensity distribution between cases. Automatic methods are highly application dependent while manual tracing methods are extremely time consuming and have a great deal of intra- and inter- observer variability. Semi-automatic approaches are designed to counterbalance the advantage and drawbacks of the automatic and manual methods. However, considerable user interaction might be necessary to ensure reasonable segmentation for a wide range of lesions. This work proposes an automatic enhancement approach to improve the boundary searching ability of the live wire method to reduce necessary user interaction while keeping the segmentation performance. Based on the results of segmentation of 50 2D breast lesions in US images, less user interaction is required to achieve desired accuracy, i.e. < 80%, when auto-enhancement is applied for live-wire segmentation.

  1. Effect of maternal Chlorella supplementation on carotenoid concentration in breast milk at early lactation.

    Science.gov (United States)

    Nagayama, Junya; Noda, Kiyoshi; Uchikawa, Takuya; Maruyama, Isao; Shimomura, Hiroshi; Miyahara, Michiyoshi

    2014-08-01

    Breast milk carotenoids provide neonates with a source of vitamin A and potentially, oxidative stress protection and other health benefits. Chlorella, which has high levels of carotenoids such as lutein, zeaxanthin and β-carotene, is an effective dietary source of carotenoids for humans. In this study, the effect of maternal supplementation with Chlorella on carotenoid levels in breast milk at early lactation was investigated. Ten healthy, pregnant women received 6 g of Chlorella daily from gestational week 16-20 until the day of delivery (Chlorella group); ten others did not (control group). Among the carotenoids detected in breast milk, lutein, zeaxanthin and β-carotene concentrations in the Chlorella group were 2.6-fold (p = 0.001), 2.7-fold (p = 0.001) and 1.7-fold (p = 0.049) higher, respectively, than those in the control group. Our study shows that Chlorella intake during pregnancy is effective in improving the carotenoid status of breast milk at early lactation.

  2. Maternal fish oil supplementation in lactation: effect on developmental outcome in breast-fed infants

    DEFF Research Database (Denmark)

    Lauritzen, L.; Jørgensen, M.H.; Olsen, S.F.

    2005-01-01

    Docosahexaenoic acid (DHA) accumulates in the brain during the 1st and 2nd years of life. The objective of this study was to see if an increased content of DHA in breast-milk via maternal fish oil (FO)-supplementation affects mental development in term infants. one hundred twenty-two Danish mothe...

  3. Perchlorate, iodine supplements, iodized salt and breast milk iodine content

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, Andrea B. [Department of Epidemiology, School of Public Health, University of North Texas Health Sciences Center, 3500 Camp Bowie Blvd., Fort Worth, TX 76107 (United States); Kroll, Martina; Dyke, Jason V.; Ohira, Shin-Ichi; Dias, Rukshan A.; Dasgupta, Purnendu K. [Department of Chemistry and Biochemistry, 700 Planetarium Place, University of Texas at Arlington, Arlington, TX 76019 (United States)

    2012-03-15

    This study was undertaken to determine if increasing maternal iodine intake through single dose tablets will decrease breast milk concentrations of the iodine-uptake inhibitor, perchlorate, through competitive inhibition. We also sought to determine if the timing of supplementation influences the fraction of iodine excreted in milk versus urine and to compare the effectiveness of iodized salt as a means of providing iodine to breastfed infants. Thirteen women who did not use supplements, seven of whom used iodized salt and six of whom used non-iodized salt, submitted four milk samples and a 24-h urine collection daily for three days. Women repeated the sampling protocol for three more days during which {approx} 150 {mu}g of iodine were taken in the evening and again for three days with morning supplementation. Samples were analyzed using isotope-dilution inductively-coupled plasma-mass spectrometry for iodine and isotope-dilution ion chromatography-tandem mass spectrometry for perchlorate. No statistically significant differences were observed in milk iodine or perchlorate concentrations during the two treatment periods. Estimated perchlorate intake was above the U.S. National Academy of Sciences suggested reference dose for most infants. Single daily dose iodine supplementation was not effective in decreasing milk perchlorate concentrations. Users of iodized salt had significantly higher iodine levels in milk than non-users. Iodized salt may be a more effective means of iodine supplementation than tablets. - Highlights: Black-Right-Pointing-Pointer Estimated infant exposures to perchlorate were, on a {mu}g/kg basis, {approx} 5 Multiplication-Sign higher than those of mothers. Black-Right-Pointing-Pointer Daily supplements are less effective than iodized salt in providing iodine to lactating women. Black-Right-Pointing-Pointer Low iodine and high perchlorate in milk may place infants at risk of iodine deficiency.

  4. Statistical analysis to assess automated level of suspicion scoring methods in breast ultrasound

    Science.gov (United States)

    Galperin, Michael

    2003-05-01

    A well-defined rule-based system has been developed for scoring 0-5 the Level of Suspicion (LOS) based on qualitative lexicon describing the ultrasound appearance of breast lesion. The purposes of the research are to asses and select one of the automated LOS scoring quantitative methods developed during preliminary studies in benign biopsies reduction. The study has used Computer Aided Imaging System (CAIS) to improve the uniformity and accuracy of applying the LOS scheme by automatically detecting, analyzing and comparing breast masses. The overall goal is to reduce biopsies on the masses with lower levels of suspicion, rather that increasing the accuracy of diagnosis of cancers (will require biopsy anyway). On complex cysts and fibroadenoma cases experienced radiologists were up to 50% less certain in true negatives than CAIS. Full correlation analysis was applied to determine which of the proposed LOS quantification methods serves CAIS accuracy the best. This paper presents current results of applying statistical analysis for automated LOS scoring quantification for breast masses with known biopsy results. It was found that First Order Ranking method yielded most the accurate results. The CAIS system (Image Companion, Data Companion software) is developed by Almen Laboratories and was used to achieve the results.

  5. Ultrasound diagnosis of fibroadenoma - is biopsy always necessary?

    Energy Technology Data Exchange (ETDEWEB)

    Smith, G.E.C. [Bradford Royal Infirmary, Bradford, West Yorkshire (United Kingdom)], E-mail: gemmaecsmith@hotmail.com; Burrows, P. [Bradford Royal Infirmary, Bradford, West Yorkshire (United Kingdom)

    2008-05-15

    Aim: To review the ultrasound characteristics of fibroadenoma and the necessity to biopsy all fibroadenomas in the under 25 years age group. Materials and methods: The details of all patients under 25 years of age who attended a large district general hospital in the UK between 1995 and 2005 with a clinical diagnosis of fibroadenoma and subsequently, underwent a breast biopsy were obtained. The report of the targeted ultrasound for these patients was reviewed and this was correlated with the histopathology report (n = 447). If there was a significant discrepancy between the ultrasound and the pathology report, the ultrasound images were reviewed. Results: Out of 447 patients 357 had an ultrasound diagnosis of fibroadenoma. This was histologically proven in 281 (78.8%) cases. In 75 (21.5%) of these patients the final histology was either another benign pathology or normal. One patient (0.3%) had an invasive carcinoma. Conclusion: The majority of patients in the 25 years and under age group have benign breast pathology, most commonly fibroadenoma. Modern ultrasound is a reliable technique to diagnose fibroadenoma in the hands of experienced breast radiologists. Therefore, in this age group, it is proposed that a palpable lump that has the ultrasound characteristics entirely consistent with a fibroadenoma need not be biopsied unless there is overriding clinical concern. The patients should be reassured, discharged, and advised to return for further evaluation only if they detect a change in the palpable abnormality.

  6. Breast biopsy -- ultrasound

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/us-guidedbreast.pdf . Updated 2016. Accessed March 14, 2017. Torrente J, Brem RF. Minimally invasive image-guided breast biopsy and ablation. In: Mauro MA, Murphy KPJ, Thomson ...

  7. The Value of Ultrasound-Guided Tattooing Localization of Nonpalpable Breast Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Kyung-Ran [National Cancer Center, Goyang (Korea, Republic of); Han, Boo-Kyung; Jang, Kyung-Mi; Choe, Yeon-Hyeon; Shin, Jung-Hee [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Yang, Jung-Hyun; Nam, Suk-Jin [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2007-08-15

    To investigate the value of ultrasound-guided tattooing localization (US-tattoo) using a charcoal suspension for breast lesions. One hundred sixty-four nonpalpable breast lesions in 134 patients (mean age 47 years; range 30 74 years) were marked with a charcoal suspension under US guidance. The medical records associated with the US-tattoo, the pathology results and the follow-up US results were reviewed. The average size of the localized lesions was 1.0 cm. The procedure time was < 5 minutes (range, 2 10 minutes) per lesion. The US-tattoo was well tolerated in all cases. The only technical difficulty encountered was a needle tip blockage caused by a large charcoal particle (4.9%). The surgeon easily identified the tattoo with the exception one case. In addition, surgery could be safely delayed from one to 57 days after the making US-tattoo. The pathology result was benign in 108 cases, borderline in five, and malignant in 51. The excised specimen was < 4 cm in 76.6% (82/107) of the benign cases (mean; 2.7 cm). The pathologist could identify the mass around the tattoo and was able to make a specific diagnosis in 81.3% (87/107) of benign lesions. The only complication encountered was residual charcoal marking along the incision scar (3.6%). All follow- up US documented the removal of the lesions. An US-tattoo for nonpalpable breast lesions is a very simple and accurate method that can help surgeons design and schedule an open biopsy.

  8. The Value of Ultrasound-Guided Tattooing Localization of Nonpalpable Breast Lesions

    International Nuclear Information System (INIS)

    Ko, Kyung-Ran; Han, Boo-Kyung; Jang, Kyung-Mi; Choe, Yeon-Hyeon; Shin, Jung-Hee; Yang, Jung-Hyun; Nam, Suk-Jin

    2007-01-01

    To investigate the value of ultrasound-guided tattooing localization (US-tattoo) using a charcoal suspension for breast lesions. One hundred sixty-four nonpalpable breast lesions in 134 patients (mean age 47 years; range 30 74 years) were marked with a charcoal suspension under US guidance. The medical records associated with the US-tattoo, the pathology results and the follow-up US results were reviewed. The average size of the localized lesions was 1.0 cm. The procedure time was < 5 minutes (range, 2 10 minutes) per lesion. The US-tattoo was well tolerated in all cases. The only technical difficulty encountered was a needle tip blockage caused by a large charcoal particle (4.9%). The surgeon easily identified the tattoo with the exception one case. In addition, surgery could be safely delayed from one to 57 days after the making US-tattoo. The pathology result was benign in 108 cases, borderline in five, and malignant in 51. The excised specimen was < 4 cm in 76.6% (82/107) of the benign cases (mean; 2.7 cm). The pathologist could identify the mass around the tattoo and was able to make a specific diagnosis in 81.3% (87/107) of benign lesions. The only complication encountered was residual charcoal marking along the incision scar (3.6%). All follow- up US documented the removal of the lesions. An US-tattoo for nonpalpable breast lesions is a very simple and accurate method that can help surgeons design and schedule an open biopsy

  9. A predictive tool to estimate the risk of axillary metastases in breast cancer patients with negative axillary ultrasound

    DEFF Research Database (Denmark)

    Meretoja, T J; Heikkilä, P S; Mansfield, A S

    2014-01-01

    of this study was to evaluate the risk factors for axillary metastases in breast cancer patients with negative preoperative axillary ultrasound. METHODS: A total of 1,395 consecutive patients with invasive breast cancer and SNB formed the original patient series. A univariate analysis was conducted to assess...... risk factors for axillary metastases. Binary logistic regression analysis was conducted to form a predictive model based on the risk factors. The predictive model was first validated internally in a patient series of 566 further patients and then externally in a patient series of 2,463 patients from......BACKGROUND: Sentinel node biopsy (SNB) is the "gold standard" in axillary staging in clinically node-negative breast cancer patients. However, axillary treatment is undergoing a paradigm shift and studies are being conducted on whether SNB may be omitted in low-risk patients. The purpose...

  10. Phyllodes tumor of the breast

    International Nuclear Information System (INIS)

    Cubells, M.; Uixera, I.; Miranda, V.; Gil de Ramales, V.; Bulto, J. A.; Mendez, M.; Morcillo, E.

    1999-01-01

    To study the phyllodes tumors of the breast diagnosed in our hospital, assessing the clinical, mammographic, ultrasonographic and color Doppler ultrasound findings. A retrospective study was carried out of 20 histologically diagnosed cases of phyllodes tumor of the breast over a 20-year period, taking into account patient age, clinical signs, mammographic and ultrasonographic findings, surgical treatment and recurrences. The clinical presentation was that of a palpable, usually painless, mass with a firm, elastic consistency. Mammographic images showed a lesion of homogeneous density and well-defined, round or lobulated margins. Two tumors contained large calcifications associated with previous fibroadenoma. Ultrasound revealed a slightly enhanced solid nodule of homogeneous echogenicity. Color Doppler ultrasound disclosed the presence of hypervascularization. The lesions were treated by surgical enucleation with follow-up examination every 6 months. Recurrences were treated by radical mastectomy. The phyllodes tumor of the breast is difficult to diagnose because of its similarity to the fibroadenoma. However, it should be suspected in the presence of a late-developing, rapidly growing mass. Mammography and breast ultrasound are of diagnostic utility, but the definitive diagnosis requires biopsy. (Author) 12 refs

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... needles are used to sample cells from an abnormal area for laboratory testing. image the breasts and ... of organs, tissues, and vessels or to detect abnormal masses, such as tumors. In an ultrasound examination, ...

  12. Ultrasound-guided wire localization of lesions detected on ...

    African Journals Online (AJOL)

    Background: Wire localization for planned surgical treatment in the management of breast cancer is underutilized in our environment. The objective of this study is to assess the role of ultrasound-guided wire localization of breast masses detected on screening mammography and its impact on biopsy and breast ...

  13. First clinical experience with a dedicated MRI-guided high-intensity focused ultrasound system for breast cancer ablation

    Energy Technology Data Exchange (ETDEWEB)

    Merckel, Laura G.; Knuttel, Floor M.; Peters, Nicky H.G.M.; Mali, Willem P.T.M.; Bosch, Maurice A.A.J. van den [University Medical Center Utrecht, Department of Radiology, HP E 01.132, Utrecht (Netherlands); Deckers, Roel; Moonen, Chrit T.W.; Bartels, Lambertus W. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Dalen, Thijs van [Diakonessenhuis Utrecht, Department of Surgery, Utrecht (Netherlands); Schubert, Gerald [Philips Healthcare, Best (Netherlands); Weits, Teun [Diakonessenhuis Utrecht, Department of Radiology, Utrecht (Netherlands); Diest, Paul J. van [University Medical Center Utrecht, Department of Pathology, Utrecht (Netherlands); Vaessen, Paul H.H.B. [University Medical Center Utrecht, Department of Anesthesiology, Utrecht (Netherlands); Gorp, Joost M.H.H. van [Diakonessenhuis Utrecht, Department of Pathology, Utrecht (Netherlands)

    2016-11-15

    To assess the safety and feasibility of MRI-guided high-intensity focused ultrasound (MR-HIFU) ablation in breast cancer patients using a dedicated breast platform. Patients with early-stage invasive breast cancer underwent partial tumour ablation prior to surgical resection. MR-HIFU ablation was performed using proton resonance frequency shift MR thermometry and an MR-HIFU system specifically designed for breast tumour ablation. The presence and extent of tumour necrosis was assessed by histopathological analysis of the surgical specimen. Pearson correlation coefficients were calculated to assess the relationship between sonication parameters, temperature increase and size of tumour necrosis at histopathology. Ten female patients underwent MR-HIFU treatment. No skin redness or burns were observed in any of the patients. No correlation was found between the applied energy and the temperature increase. In six patients, tumour necrosis was observed with a maximum diameter of 3-11 mm. In these patients, the number of targeted locations was equal to the number of areas with tumour necrosis. A good correlation was found between the applied energy and the size of tumour necrosis at histopathology (Pearson = 0.76, p = 0.002). Our results show that MR-HIFU ablation with the dedicated breast system is safe and results in histopathologically proven tumour necrosis. (orig.)

  14. Imaging Management of Breast Density, a Controversial Risk Factor for Breast Cancer.

    Science.gov (United States)

    Falcon, Shannon; Williams, Angela; Weinfurtner, Jared; Drukteinis, Jennifer S

    2017-04-01

    Breast density is well recognized as an independent risk factor for the development of breast cancer. However, the magnitude of risk is controversial. As the public becomes increasingly aware of breast density as a risk factor, legislation and notification laws in relation to breast density have become common throughout the United States. Awareness of breast density as a risk factor for breast cancer presents new challenges for the clinician in the approach to the management and screening of women with dense breasts. The evidence and controversy surrounding breast density as a risk factor for the development of breast cancer are discussed. Common supplemental screening modalities for breast cancer are also discussed, including tomosynthesis, ultrasonography, and magnetic resonance imaging. A management strategy for screening women with dense breasts is also presented. The American College of Radiology recognizes breast density as a controversial risk factor for breast cancer, whereas the American Congress of Obstetricians and Gynecologists recognizes breast density as a modest risk factor. Neither organization recommends the routine use of supplemental screening in women with dense breasts without considering additional patient-related risk factors. Breast density is a poorly understood and controversial risk factor for the development of breast cancer. Mammography is a screening modality proven to reduce breast cancer-related mortality rates and is the single most appropriate tool for population-based screening. Use of supplemental screening modalities should be tailored to individual risk assessment.

  15. Comparison between infants receiving traditional supplements (camel thorn, flix weed, and sugar water and exclusively breast fed infants

    Directory of Open Access Journals (Sweden)

    Hassan Boskabadi

    2015-10-01

    Full Text Available Objectives: Although breast milk is considered the best nutritional option for neonates, use of traditional supplements such as sugar water, camel thorn, and flix weed in the first week of life of infants is quite common in Iran and many other countries. The aim of this study was to evaluate whether consuming such supplements has any impact on infant’s breastfeeding behavior. Materials and Methods: Four hundred fifty four term infants who were referred to the neonatal clinic of Ghaem hospital were enrolled and divided into two groups. Control (exclusively breastfed infants, N=243 and case (breast milk feeding plus traditional remedies such as sugar water, camel thorn, and flix weed, N=211. Spss 19.5 was used for statistical analysis. T-test and Man-Whitney tests were used. A p-value of Results: The two groups were similar in their baseline data. Regarding duration of breastfeeding and breastfeeding frequency, use of these supplements resulted in a reduction in both breastfeeding frequency and duration (p

  16. Estimation of Tumor Angiogenesis With Contrast Enhanced Subharmonic Ultrasound Imaging

    National Research Council Canada - National Science Library

    Forsberg, Flemming

    2002-01-01

    .... Hence, the current project proposes to increase the ability of breast ultrasound to differentiate between benign and malignant lesions by combining injection of an ultrasound contrast agent with SHI...

  17. Estimation of Tumor Angiogenesis with Contrast Enhanced Subharmonic Ultrasound Imaging

    National Research Council Canada - National Science Library

    Forsberg, Flemming

    2004-01-01

    .... Hence, the current project proposes to increase the ability of breast ultrasound to differentiate between benign and malignant lesions by combining injection of an ultrasound contrast agent with SHI...

  18. Estimation of Tumor Angiogenesis With Constrast Enhanced Subharmonic Ultrasound Imaging

    National Research Council Canada - National Science Library

    Forsberg, Fleming

    2003-01-01

    .... Hence, the current project proposes to increase the ability of breast ultrasound to differentiate between denign and malignant lesions by combining injection of an ultrasound contrast agent with SHI...

  19. Ultrasound breast imaging using frequency domain reverse time migration

    Science.gov (United States)

    Roy, O.; Zuberi, M. A. H.; Pratt, R. G.; Duric, N.

    2016-04-01

    Conventional ultrasonography reconstruction techniques, such as B-mode, are based on a simple wave propagation model derived from a high frequency approximation. Therefore, to minimize model mismatch, the central frequency of the input pulse is typically chosen between 3 and 15 megahertz. Despite the increase in theoretical resolution, operating at higher frequencies comes at the cost of lower signal-to-noise ratio. This ultimately degrades the image contrast and overall quality at higher imaging depths. To address this issue, we investigate a reflection imaging technique, known as reverse time migration, which uses a more accurate propagation model for reconstruction. We present preliminary simulation results as well as physical phantom image reconstructions obtained using data acquired with a breast imaging ultrasound tomography prototype. The original reconstructions are filtered to remove low-wavenumber artifacts that arise due to the inclusion of the direct arrivals. We demonstrate the advantage of using an accurate sound speed model in the reverse time migration process. We also explain how the increase in computational complexity can be mitigated using a frequency domain approach and a parallel computing platform.

  20. Interpretation Time Using a Concurrent-Read Computer-Aided Detection System for Automated Breast Ultrasound in Breast Cancer Screening of Women With Dense Breast Tissue.

    Science.gov (United States)

    Jiang, Yulei; Inciardi, Marc F; Edwards, Alexandra V; Papaioannou, John

    2018-05-24

    The purpose of this study was to compare diagnostic accuracy and interpretation time of screening automated breast ultrasound (ABUS) for women with dense breast tissue without and with use of a recently U.S. Food and Drug Administration-approved computer-aided detection (CAD) system for concurrent read. In a retrospective observer performance study, 18 radiologists interpreted a cancer-enriched set (i.e., cancer prevalence higher than in the original screening cohort) of 185 screening ABUS studies (52 with and 133 without breast cancer). These studies were from a large cohort of ABUS screened patients interpreted as BI-RADS density C or D. Each reader interpreted each case twice in a counterbalanced study, once without the CAD system and once with it, separated by 4 weeks. For each case, each reader identified abnormal findings and reported BI-RADS assessment category and level of suspicion for breast cancer. Interpretation time was recorded. Level of suspicion data were compared to evaluate diagnostic accuracy by means of the Dorfman-Berbaum-Metz method of jackknife with ANOVA ROC analysis. Interpretation times were compared by ANOVA. The ROC AUC was 0.848 with the CAD system, compared with 0.828 without it, for a difference of 0.020 (95% CI, -0.011 to 0.051) and was statistically noninferior to the AUC without the CAD system with respect to a margin of -0.05 (p = 0.000086). The mean interpretation time was 3 minutes 33 seconds per case without the CAD system and 2 minutes 24 seconds with it, for a difference of 1 minute 9 seconds saved (95% CI, 44-93 seconds; p = 0.000014), or a reduction in interpretation time to 67% of the time without the CAD system. Use of the concurrent-read CAD system for interpretation of screening ABUS studies of women with dense breast tissue who do not have symptoms is expected to make interpretation significantly faster and produce noninferior diagnostic accuracy compared with interpretation without the CAD system.

  1. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    International Nuclear Information System (INIS)

    Kang, Yun Dan; Kim, You Me

    2016-01-01

    The purpose of this study was to compare needle aspiration and vacuum-assisted biopsy in the ultrasound-guided treatment of lactational breast abscesses. Between January 2005 and December 2014, a total of 74 patients presented with lactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated with needle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student's t test and the chi-square test were used to compare the variables. No significant difference was found in the cure rate between the needle aspiration group (22/25, 88%) and the vacuum-assisted biopsy group (18/19, 94.7%) (P=0.441). However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days) than in the needle aspiration group (9.0 days) (P=0.001). Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses

  2. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    Directory of Open Access Journals (Sweden)

    Yun-Dan Kang

    2016-04-01

    Full Text Available Purpose: The purpose of this study was to compare needle aspiration and vacuum-assistedbiopsy in the ultrasound-guided treatment of lactational breast abscesses. Methods: Between January 2005 and December 2014, a total of 74 patients presented withlactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated withneedle aspiration (n=25 or vacuum-assisted biopsy (n=19. Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student’s t test and the chi-square test were used to compare the variables. Results: No significant difference was found in the cure rate between the needle aspirationgroup (22/25, 88% and the vacuum-assisted biopsy group (18/19, 94.7% (P=0.441. However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days than in the needle aspiration group (9.0 days (P=0.001. Conclusion: Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses.

  3. Comparison of needle aspiration and vacuum-assisted biopsy in the ultrasound-guided drainage of lactational breast abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yun Dan; Kim, You Me [Dankook University College of Medicine, Cheonan (Korea, Republic of)

    2016-03-15

    The purpose of this study was to compare needle aspiration and vacuum-assisted biopsy in the ultrasound-guided treatment of lactational breast abscesses. Between January 2005 and December 2014, a total of 74 patients presented with lactational breast abscesses. Thirty of these patients underwent treatment with antibioticsalone, while the remaining 44 lactating women with breast abscesses were treated with needle aspiration (n=25) or vacuum-assisted biopsy (n=19). Age, duration of lactation, abscess diameter, pus culture results, the number of interventions, the healing time, and the cure rate were reviewed and compared between these two groups. The Student's t test and the chi-square test were used to compare the variables. No significant difference was found in the cure rate between the needle aspiration group (22/25, 88%) and the vacuum-assisted biopsy group (18/19, 94.7%) (P=0.441). However, the mean healing time was significantly shorter in the vacuum-assisted biopsy group (6.7 days) than in the needle aspiration group (9.0 days) (P=0.001). Vacuum-assisted biopsy is a viable option for the management of lactational breast abscesses and was found to lead to a shorter healing time than needle aspiration. However, further study is necessary to establish the clinical efficacy of vacuum-assisted biopsy in the management of lactational breast abscesses.

  4. Quantitative ultrasound assessment of breast tumor response to chemotherapy using a multi-parameter approach.

    Science.gov (United States)

    Tadayyon, Hadi; Sannachi, Lakshmanan; Gangeh, Mehrdad; Sadeghi-Naini, Ali; Tran, William; Trudeau, Maureen E; Pritchard, Kathleen; Ghandi, Sonal; Verma, Sunil; Czarnota, Gregory J

    2016-07-19

    This study demonstrated the ability of quantitative ultrasound (QUS) parameters in providing an early prediction of tumor response to neoadjuvant chemotherapy (NAC) in patients with locally advanced breast cancer (LABC). Using a 6-MHz array transducer, ultrasound radiofrequency (RF) data were collected from 58 LABC patients prior to NAC treatment and at weeks 1, 4, and 8 of their treatment, and prior to surgery. QUS parameters including midband fit (MBF), spectral slope (SS), spectral intercept (SI), spacing among scatterers (SAS), attenuation coefficient estimate (ACE), average scatterer diameter (ASD), and average acoustic concentration (AAC) were determined from the tumor region of interest. Ultrasound data were compared with the ultimate clinical and pathological response of the patient's tumor to treatment and patient recurrence-free survival. Multi-parameter discriminant analysis using the κ-nearest-neighbor classifier demonstrated that the best response classification could be achieved using the combination of MBF, SS, and SAS, with an accuracy of 60 ± 10% at week 1, 77 ± 8% at week 4 and 75 ± 6% at week 8. Furthermore, when the QUS measurements at each time (week) were combined with pre-treatment (week 0) QUS values, the classification accuracies improved (70 ± 9% at week 1, 80 ± 5% at week 4, and 81 ± 6% at week 8). Finally, the multi-parameter QUS model demonstrated a significant difference in survival rates of responding and non-responding patients at weeks 1 and 4 (p=0.035, and 0.027, respectively). This study demonstrated for the first time, using new parameters tested on relatively large patient cohort and leave-one-out classifier evaluation, that a hybrid QUS biomarker including MBF, SS, and SAS could, with relatively high sensitivity and specificity, detect the response of LABC tumors to NAC as early as after 4 weeks of therapy. The findings of this study also suggested that incorporating pre-treatment QUS parameters of a tumor improved the

  5. Breast magnetic resonance imaging for surveillance of women with a personal history of breast cancer: outcomes stratified by interval between definitive surgery and surveillance MR imaging.

    Science.gov (United States)

    Park, Vivian Youngjean; Kim, Eun-Kyung; Kim, Min Jung; Moon, Hee Jung; Yoon, Jung Hyun

    2018-01-22

    Women with a personal history of breast cancer are at increased risk of future breast cancer events, and may benefit from supplemental screening methods that could enhance early detection of subclinical disease. However, current literature on breast magnetic resonance (MR) imaging surveillance is limited. We investigated outcomes of surveillance breast magnetic resonance (MR) imaging in women with a personal history of breast cancer. We reviewed 1053 consecutive breast MR examinations that were performed for surveillance in 1044 women (median age, 53 years; range, 20-85 years) previously treated for breast cancer between August 2014 and February 2016. All patients had previously received supplemental surveillance with ultrasound. Cancer detection rate (CDR), abnormal interpretation rate and characteristics of MR-detected cancers were assessed, including extramammary cancers. We also calculated the PPV 1 , PPV 3 , sensitivity and specificity for MR-detected intramammary lesions. Performance statistics were stratified by interval following initial surgery. The CDR for MR-detected cancers was 6.7 per 1000 examinations (7 of 1053) and was 3.8 per 1000 examinations (4 of 1053) for intramammary cancers. The overall abnormal interpretation rate was 8.0%, and the abnormal interpretation rate for intramammary lesions was 7.2%. The PPV 1 , PPV 3 , sensitivity and specificity for intramammary lesions was 5.3% (4 of 76), 15.8% (3 of 19), 75.0% (3 of 4) and 98.3% (1031 of 1049), respectively. For MR examinations performed ≤36 months after surgery, the overall CDR was 1.4 per 1000 examinations. For MR examinations performed > 36 months after surgery, the overall CDR was 17.4 per 1000 examinations. Surveillance breast MR imaging may be considered in women with a history of breast cancer, considering the low abnormal interpretation rate and its high specificity. However, the cancer detection rate was low and implementation may be more effective after more than 3

  6. The Effect of Symbiotic Supplementation on Liver Enzymes, C-reactive Protein and Ultrasound Findings in Patients with Non-alcoholic Fatty Liver Disease: A Clinical Trial.

    Science.gov (United States)

    Asgharian, Atefe; Askari, Gholamreza; Esmailzade, Ahmad; Feizi, Awat; Mohammadi, Vida

    2016-01-01

    Regarding to the growing prevalence of nonalcoholic fatty liver disease (NAFLD), concentrating on various strategies to its prevention and management seems necessary. The aim of this study was to determine the effects of symbiotic on C-reactive protein (CRP), liver enzymes, and ultrasound findings in patients with NAFLD. Eighty NAFLD patients were enrolled in this randomized, double-blind, placebo-controlled clinical trial. Participants received symbiotic in form of a 500 mg capsule (containing seven species of probiotic bacteria and fructooligosaccharides) or a placebo capsule daily for 8 weeks. Ultrasound grading, CRP, and liver enzymes were evaluated at the baseline and the end of the study. In the symbiotic group, ultrasound grade decreased significantly compared to baseline (P symbiotic supplementation was not associated with changes in alanine aminotransferase (ALT) and aspartate transaminase (AST) levels. In the placebo group, there was no significant change in steatosis grade whereas ALT and AST levels were significantly increased (P = 0.002, P = 0.02, respectively). CRP values remained static in either group. Symbiotic supplementation improved steatosis in NAFLD patients and might be useful in the management of NAFLD or protective against its progression.

  7. The accuracy of frozen section analysis in ultrasound- guided core needle biopsy of breast lesions

    International Nuclear Information System (INIS)

    Brunner, Andreas H; Sagmeister, Thomas; Kremer, Jolanta; Riss, Paul; Brustmann, Hermann

    2009-01-01

    Limited data are available to evaluate the accuracy of frozen section analysis and ultrasound- guided core needle biopsy of the breast. In a retrospective analysis data of 120 consecutive handheldultrasound- guided 14- gauge automated core needle biopsies (CNB) in 109 consecutive patients with breast lesions between 2006 and 2007 were evaluated. In our outpatient clinic120 CNB were performed. In 59/120 (49.2%) cases we compared histological diagnosis on frozen sections with those on paraffin sections of CNB and finally with the result of open biopsy. Of the cases 42/59 (71.2%) were proved to be malignant and 17/59 (28.8%) to be benign in the definitive histology. 2/59 (3.3%) biopsies had a false negative frozen section result. No false positive results of the intraoperative frozen section analysis were obtained, resulting in a sensitivity, specificity and positive predicting value (PPV) and negative predicting value (NPV) of 95%, 100%, 100% and 90%, respectively. Histological and morphobiological parameters did not show up relevance for correct frozen section analysis. In cases of malignancy time between diagnosis and definitive treatment could not be reduced due to frozen section analysis. The frozen section analysis of suspect breast lesions performed by CNB displays good sensitivity/specificity characteristics. Immediate investigations of CNB is an accurate diagnostic tool and an important step in reducing psychological strain by minimizing the period of uncertainty in patients with breast tumor

  8. Evaluation of breast implants with breast magnetic resonance: Practical utility in comparison with other methods

    International Nuclear Information System (INIS)

    Melendez, Florencia; Blejman, Oscar; Lamattina Mariano; Villamea, Victoria; Sarquis, Flavio; Torrillo, Fabiana

    2010-01-01

    The purpose of this study was to demonstrate the utility of Breast Magnetic Resonance (BMR) in the evaluation of breast implants comparing Mammography and Breast ultrasound in an ambulatory private institute setting. Method: Between May 2008 and April 2010, 729 BRM were performed in patients between 22 and 77 years of age, 474 were evaluated for implant integrity. The studies were performed in a high field equipment (1.5T) with T1, T2, fat Sat, Silicone only and silicone suppression sequences. Results: Of the 474 patients that were evaluated for implant integrity: 291 patients (61.39%) presented with intact implants, 252 (86.6%) showed concordant findings with mammography and or ultrasound and 39 (13.4%) showed discordant findings. Then, 116 patients (24.47%) presented signs of intracapsular rupture, 82 (70.7%) were concordant with ultrasound findings and 34 (29.3%) had normal ultrasound evaluation. 44 patients (9.28%) presented extracapsular rupture, 40 (90.9%) were concordant with mammography and ultrasound and 4 (9.10%) were discordant. Finally, 23 patients (4.85%) presented residual silicone granulomas, with history of previous implant rupture and explanted surgery, 13 (56.52%) concordant with mammography and ultrasound and 10 (43.48%) were discordant. Conclusion: Non contrast BMR, using multiples planes and sequences is very useful in the evaluation of the internal structure of the implants and extracapsular silicone. It's the most sensible study to demonstrate intra and extracapsular rupture. BMR exceeds mammography and ultrasound in the detection of implant rupture and residual granulomas following explanted surgery.

  9. Evaluation of a three-dimensional ultrasound localisation system incorporating probe pressure correction for use in partial breast irradiation.

    Science.gov (United States)

    Harris, E J; Symonds-Taylor, R; Treece, G M; Gee, A H; Prager, R W; Brabants, P; Evans, P M

    2009-10-01

    This work evaluates a three-dimensional (3D) freehand ultrasound-based localisation system with new probe pressure correction for use in partial breast irradiation. Accuracy and precision of absolute position measurement was measured as a function of imaging depth (ID), object depth, scanning direction and time using a water phantom containing crossed wires. To quantify the improvement in accuracy due to pressure correction, 3D scans of a breast phantom containing ball bearings were obtained with and without pressure. Ball bearing displacements were then measured with and without pressure correction. Using a single scan direction (for all imaging depths), the mean error was <1.3 mm, with the exception of the wires at 68.5 mm imaged with an ID of 85 mm, which gave a mean error of -2.3 mm. Precision was greater than 1 mm for any single scan direction. For multiple scan directions, precision was within 1.7 mm. Probe pressure corrections of between 0 mm and 2.2 mm have been observed for pressure displacements of 1.1 mm to 4.2 mm. Overall, anteroposterior position measurement accuracy increased from 2.2 mm to 1.6 mm and to 1.4 mm for the two opposing scanning directions. Precision is comparable to that reported for other commercially available ultrasound localisation systems, provided that 3D image acquisition is performed in the same scan direction. The existing temporal calibration is imperfect and a "per installation" calibration would further improve the accuracy and precision. Probe pressure correction was shown to improve the accuracy and will be useful for the localisation of the excision cavity in partial breast radiotherapy.

  10. Estimation of Tumor Angiogenesis With Contrast Enhanced Subharmonic Ultrasound Imaging

    National Research Council Canada - National Science Library

    Forsberg, Flemming

    2005-01-01

    ...) and receiving at the subharmonic (f0). Hence, the current project proposes to increase the ability of breast ultrasound to differentiate between benign and malignant lesions by combining injection of an ultrasound contrast agent with SHI...

  11. Probiotic supplementation and fast freezing to improve quality attributes and oxidation stability of frozen chicken breast muscle

    Science.gov (United States)

    The objective of this study was to determine the effects of probiotic supplementation and fast freezing on quality attributes and oxidation stability of frozen/thawed chicken breast meat. Broilers were fed with a basal diet or the basal diet plus 250 ppm Sporulin (three strains of Bacillus subtilis)...

  12. Retrospective and comparative analysis of 99mTc-Sestamibi breast specific gamma imaging versus mammography, ultrasound, and magnetic resonance imaging for the detection of breast cancer in Chinese women

    International Nuclear Information System (INIS)

    Yu, Xiuyan; Hu, Guoming; Zhang, Zhigang; Qiu, Fuming; Shao, Xuan; Wang, Xiaochen; Zhan, Hongwei; Chen, Yiding; Deng, Yongchuan; Huang, Jian

    2016-01-01

    Diagnosing breast cancer during the early stage may be helpful for decreasing cancer-related mortality. In Western developed countries, mammographies have been the gold standard for breast cancer detection. However, Chinese women usually have denser and smaller-sized breasts compared to Caucasian women, which decreases the diagnostic accuracy of mammography. However, breast specific gamma imaging, a type of molecular functional breast imaging, has been used for the accurate diagnosis of breast cancer and is not influenced by breast density. Our objective was to analyze the breast specific gamma imaging (BSGI) diagnostic value for Chinese women. During a 2-year period, 357 women were diagnosed and treated at our oncology department and received BSGI in addition to mammography (MMG), ultrasound (US) and magnetic resonance imaging (MRI) for diagnostic assessment. We investigated the sensitivity and specificity of each method of detection and compared the biological profiles of the four imaging methods. A total of 357 women received a final surgical pathology diagnosis, with 168 malignant diseases (58.5 %) and 119 benign diseases (41.5 %). Of these, 166 underwent the four imaging tests preoperatively. The sensitivity of BSGI was 80.35 and 82.14 % by US, 75.6 % by MMG, and 94.06 % by MRI. Furthermore, the breast cancer diagnosis specificity of BSGI was high (83.19 % vs. 77.31 % vs. 66.39 % vs. 67.69 %, respectively). The BSGI diagnostic sensitivity for mammographic breast density in women was superior to mammography and more sensitive for non-luminal A subtypes (luminal A vs. non-luminal A, 68.63 % vs. 88.30 %). BSGI may help improve the ability to diagnose early stage breast cancer for Chinese women, particularly for ductal carcinoma in situ (DCIS), mammographic breast density and non-luminal A breast cancer

  13. Retrospective and comparative analysis of (99m)Tc-Sestamibi breast specific gamma imaging versus mammography, ultrasound, and magnetic resonance imaging for the detection of breast cancer in Chinese women.

    Science.gov (United States)

    Yu, Xiuyan; Hu, Guoming; Zhang, Zhigang; Qiu, Fuming; Shao, Xuan; Wang, Xiaochen; Zhan, Hongwei; Chen, Yiding; Deng, Yongchuan; Huang, Jian

    2016-07-11

    Diagnosing breast cancer during the early stage may be helpful for decreasing cancer-related mortality. In Western developed countries, mammographies have been the gold standard for breast cancer detection. However, Chinese women usually have denser and smaller-sized breasts compared to Caucasian women, which decreases the diagnostic accuracy of mammography. However, breast specific gamma imaging, a type of molecular functional breast imaging, has been used for the accurate diagnosis of breast cancer and is not influenced by breast density. Our objective was to analyze the breast specific gamma imaging (BSGI) diagnostic value for Chinese women. During a 2-year period, 357 women were diagnosed and treated at our oncology department and received BSGI in addition to mammography (MMG), ultrasound (US) and magnetic resonance imaging (MRI) for diagnostic assessment. We investigated the sensitivity and specificity of each method of detection and compared the biological profiles of the four imaging methods. A total of 357 women received a final surgical pathology diagnosis, with 168 malignant diseases (58.5 %) and 119 benign diseases (41.5 %). Of these, 166 underwent the four imaging tests preoperatively. The sensitivity of BSGI was 80.35 and 82.14 % by US, 75.6 % by MMG, and 94.06 % by MRI. Furthermore, the breast cancer diagnosis specificity of BSGI was high (83.19 % vs. 77.31 % vs. 66.39 % vs. 67.69 %, respectively). The BSGI diagnostic sensitivity for mammographic breast density in women was superior to mammography and more sensitive for non-luminal A subtypes (luminal A vs. non-luminal A, 68.63 % vs. 88.30 %). BSGI may help improve the ability to diagnose early stage breast cancer for Chinese women, particularly for ductal carcinoma in situ (DCIS), mammographic breast density and non-luminal A breast cancer.

  14. Bioactive dietary supplements reactivate ER expression in ER-negative breast cancer cells by active chromatin modifications.

    Directory of Open Access Journals (Sweden)

    Syed M Meeran

    Full Text Available Breast cancer is the most common cancer and the leading cause of cancer death in women. Although tamoxifen therapy is successful for some patients, it does not provide adequate benefit for those who have estrogen receptor (ER-negative cancers. Therefore, we approached novel treatment strategies by combining two potential bioactive dietary supplements for the reactivation of ERα expression for effective treatment of ERα-negative breast cancer with tamoxifen. Bioactive dietary supplements such as green tea polyphenols (GTPs and sulforaphane (SFN inhibit DNA methyltransferases (DNMTs and histone deacetylases (HDACs, respectively, which are of central importance to cancer prevention. In the present study, we have observed that treatment of ERα-negative breast cancer cells with GTPs and SFN alone or in combination leads to the reactivation of ERα expression. The combination of 20 µg/mL GTPs and 5 µM SFN was found to be the optimal dose of ERα-reactivation at 3 days in MDA-MB-231 cells. The reactivation of ERα expression was consistently correlated with ERα promoter hypomethylation and hyperacetylation. Chromatin immunoprecipitation (ChIP analysis of the ERα promoter revealed that GTPs and SFN altered the binding of ERα-transcriptional co-repressor complex thereby contributing to ERα-reactivation. In addition, treatment with tamoxifen in combination with GTPs and SFN significantly increased both cell death and inhibition of cellular proliferation in MDA-MB-231 cells in comparison to treatment with tamoxifen alone. Collectively, our findings suggest that a novel combination of bioactive-HDAC inhibitors with bioactive-demethylating agents is a promising strategy for the effective treatment of hormonal refractory breast cancer with available anti-estrogens.

  15. Hand-held and automated breast ultrasound

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.; Kimme-Smith, C.

    1985-01-01

    The book is a guide for physicians and technologists who use US as an adjunct to mammography; it carefully outlines the pros and cons of US of the breast and its role in the diagnosis of benign and malignant diseases. After an introduction that discusses the philosophy of breast US, the chapters cover the physics of US and instrumentation (both hand-held transducers as well as automated water path scanners), then proceed to a discussion of the normal breast. Sections on benign disorders, malignant lesions, and pitfalls of diagnosis are followed by quiz cases

  16. Nodular breast lymphoma

    International Nuclear Information System (INIS)

    Rodriguez, M.; Sahagun, E.; Pena, J.; Mendez, J.

    1996-01-01

    We attempt to correlate the histological types [in three cases of B-cell non-Hodgkin's lymphoma (NHL), one case of T-cell NHL and one of Hodgkin's disease] with the radiological presentation and compare our findings with the literature reviewed. Among the mammographic studies, performed over and 18-month period, we have assessed five patients (four women and one man, aged as having lymphoma. the man presented bilateral involvement. Both mammography and a broader study with ultrasound and chest and abdominal CT scan were performed in every case. Four patients underwent breast ultrasound. The definitive diagnosis was based on biopsy in all cases. Three of the five cases involved primary lymphomas and the other two were secondary. Four patients presented NHL and the remaining patient had Hodgkin's disease. In mammography, the nodules showed different degrees of margin definition. In ultrasound, all the lesion were hypoechoic. The radiological diagnosis of breast lymphoma is difficult in the absence of a previous diagnosis of lymphoma. This lesion should be included in the differential diagnosis in the presence of a breast nodule associated with axillary lymph nodes, especially when the latter are bilateral. (Author)

  17. Impact of axillary ultrasound and core needle biopsy on the utility of intraoperative frozen section analysis and treatment decision making in women with invasive breast cancer.

    Science.gov (United States)

    Caretta-Weyer, Holly; Sisney, Gale A; Beckman, Catherine; Burnside, Elizabeth S; Salkowsi, Lonie R; Strigel, Roberta M; Wilke, Lee G; Neuman, Heather B

    2012-09-01

    Our objective was to evaluate the impact of preoperative axillary ultrasound and core needle biopsy (CNB) on breast cancer treatment decision making. A secondary aim was to evaluate the impact on the utility of intraoperative sentinel lymph node (SLN) frozen section. A review of 84 patients with clinically negative axilla who underwent axillary ultrasound was performed. Sensitivity, specificity, and positive/negative predictive value for axillary ultrasound with CNB was calculated. Thirty-one (37%) had suspicious nodes. Of 27 amenable to CNB, 12 (14%) were malignant, changing treatment plans. The sensitivity of ultrasound and CNB was 54% and specificity 100%; the positive and negative predictive values were 100% and 80%, respectively. In 41 patients with normal ultrasounds who underwent SLN frozen section, 10 (24%) were positive. Preoperative axillary ultrasound impacts treatment decision making in 14%. With a sensitivity of 54%, it is a useful adjunct to, but not replacement for, SLN biopsy. Frozen section remains of utility even after a negative axillary ultrasound. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Vitamin D supplementation and breast cancer prevention: a systematic review and meta-analysis of randomized clinical trials.

    Directory of Open Access Journals (Sweden)

    Francesca Sperati

    Full Text Available In recent years, the scientific evidence linking vitamin D status or supplementation to breast cancer has grown notably. To investigate the role of vitamin D supplementation on breast cancer incidence, we conducted a systematic review and meta-analysis of randomized controlled trials comparing vitamin D with placebo or no treatment. We used OVID to search MEDLINE (R, EMBASE and CENTRAL until April 2012. We screened the reference lists of included studies and used the "Related Article" feature in PubMed to identify additional articles. No language restrictions were applied. Two reviewers independently extracted data on methodological quality, participants, intervention, comparison and outcomes. Risk Ratios and 95% Confident Intervals for breast cancer were pooled using a random-effects model. Heterogeneity was assessed using the I(2 test. In sensitivity analysis, we assessed the impact of vitamin D dosage and mode of administration on treatment effects. Only two randomized controlled trials fulfilled the pre-set inclusion criteria. The pooled analysis included 5372 postmenopausal women. Overall, Risk Ratios and 95% Confident Intervals were 1.11 and 0.74-1.68. We found no evidence of heterogeneity. Neither vitamin D dosage nor mode of administration significantly affected breast cancer risk. However, treatment efficacy was somewhat greater when vitamin D was administered at the highest dosage and in combination with calcium (Risk Ratio 0.58, 95% Confident Interval 0.23-1.47 and Risk Ratio 0.93, 95% Confident Interval 0.54-1.60, respectively. In conclusions, vitamin D use seems not to be associated with a reduced risk of breast cancer development in postmenopausal women. However, the available evidence is still limited and inadequate to draw firm conclusions. Study protocol code: FARM8L2B5L.

  19. Principal component analysis of sensory properties of chicken breast muscle supplemented with different feed additives

    Directory of Open Access Journals (Sweden)

    Peter Haščík

    2017-01-01

    Full Text Available The objective of the present study was to examine the effect of different dietary supplements (bee pollen, propolis, and probiotic on sensory quality of chicken breast muscle. The experiment was performed with 180 one day-old Ross 308 broiler chicks of mixed sex. The dietary treatments were as follows: 1. basal diet with no supplementation as control (C; 2. basal diet plus 400 mg bee pollen extract per 1 kg of feed mixture (E1; 3. basal diet plus 400 mg propolis extract per 1 kg of feed mixture (E2; 4. basal diet plus 3.3 g probiotic preparation based on Lactobacillus fermentum added to drinking water (E3. Sensory properties of chicken breast muscle were assessed by a five-member panel that rated the meat for aroma, taste, juiciness, tenderness and overall acceptability. The ANOVA results for each attribute showed that at least one mean score for any group differs significantly (p ≤0.05. Subsequent Tukey's HSD revealed that only C group had significantly higher mean score (p ≤0.05 for each attribute compared with E2 group. As regards the E1 and E3 groups, there were not significant differences (p >0.05 in aroma, taste and tenderness when compared to C group, with the significantly lowest juiciness value (p ≤0.05 found in E3 group and significantly lower values of overall acceptability in both groups (p ≤0.05. In addition, it is noteworthy that control group received the highest raking scores for each sensory attribute, i.e. the supplements did not influence positively the sensory quality of chicken breast meat. Principal component analysis (PCA of the sensory data showed that the first 3 principal components (PCs explained 69.82% of the total variation in 5 variables. Visualisation of extracted PCs has shown that groups were very well represented, with E2 group clearly distinguished from the others.  Normal 0 21 false false false SK X-NONE X-NONE

  20. The decrease effect of music on anxiety and distress of patients undergoing ultrasound guided core biopsy of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Ae Rang [Dept. of Diagnostic Radiology, St. Carollo General Hospital, Suncheon (Korea, Republic of); Sohn, Seok Joon [Dept. of Preventive Medicine, Chonnam National University Medical School, Chonnam National University Hospital, Gwangju (Korea, Republic of); Moon, Il Bong; Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)

    2017-06-15

    The aim of this study was to investigate that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic. One hundred patients underwent Ultrasound Guided Core Biopsy of the Breast. Each patients was allocated to one of two groups with different methods whether they listened to music or not. The experimental group listening to music are 50 patients and the control group are 50 patients. The difference of VAS anxiety score of pre-test and post-test was signifcant (p<0.001). Compared by the control group, the subjective distress of the patients listening to music such as pain and tension was significant (p<0.001) but nausea and dyspnea was not significant. The objective distress of the patients listening to music was statistically significant (p<0.001). The Differances of systolic blood pressure, diastolic blood pressure, pulse between pre-test and post-test were not signifcant. The results suggest that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic.

  1. The decrease effect of music on anxiety and distress of patients undergoing ultrasound guided core biopsy of the breast

    International Nuclear Information System (INIS)

    Woo, Ae Rang; Sohn, Seok Joon; Moon, Il Bong; Dong, Kyung Rae

    2017-01-01

    The aim of this study was to investigate that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic. One hundred patients underwent Ultrasound Guided Core Biopsy of the Breast. Each patients was allocated to one of two groups with different methods whether they listened to music or not. The experimental group listening to music are 50 patients and the control group are 50 patients. The difference of VAS anxiety score of pre-test and post-test was signifcant (p<0.001). Compared by the control group, the subjective distress of the patients listening to music such as pain and tension was significant (p<0.001) but nausea and dyspnea was not significant. The objective distress of the patients listening to music was statistically significant (p<0.001). The Differances of systolic blood pressure, diastolic blood pressure, pulse between pre-test and post-test were not signifcant. The results suggest that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic

  2. Ultrasound-Guided Optical Tomographic Imaging of Malignant and Benign Breast Lesions: Initial Clinical Results of 19 Cases

    Directory of Open Access Journals (Sweden)

    Quing Zhu

    2003-09-01

    Full Text Available The diagnosis of solid benign and malignant tumors presents a unique challenge to all noninvasive imaging modalities. Ultrasound is used in conjunction with mammography to differentiate simple cysts from solid lesions. However, the overlapping appearances of benign and malignant lesions make ultrasound less useful in differentiating solid lesions, resulting in a large number of benign biopsies. Optical tomography using near-infrared diffused light has great potential for imaging functional parameters of 1 tumor hemoglobin concentration, 2 oxygen saturation, 3 metabolism, as well as other tumor distinguishing characteristics. These parameters can differentiate benign from malignant lesions. However, optical tomography, when used alone, suffers from low spatial resolution and target localization uncertainty due to intensive light scattering. Our aim is to combine diffused light imaging with ultrasound in a novel way for the detection and diagnosis of solid lesions. Initial findings of two earlystage invasive carcinomas, one combined fibroadenoma and fibrocystic change with scattered foci of lobular neoplasia/lobular carcinoma in situ, 16 benign lesions are reported in this paper. The invasive cancer cases reveal about two-fold greater total hemoglobin concentration (mean 119 μmol than benign cases (mean 67 μmol, suggest that the discrimination of benign and malignant breast lesions might be enhanced by this type of achievable optical quantification with ultrasound localization. Furthermore, the small invasive cancers are well localized and have wavelength-dependent appearance in optical absorption maps, whereas the benign lesions appear diffused and relatively wavelength-independent.

  3. Negative predictive value of ultrasound in predicting tumor-free margins in specimen sonography

    International Nuclear Information System (INIS)

    Naz, S.; Hafeez, S.; Hussain, Z.; Hilal, K.

    2017-01-01

    Objective: To evaluate the success of ultrasound in post-excision specimen visualization, and negative predictive value of ultrasound for estimation of tumor-free margins using histopathology as the gold standard. Study Design: Cross-sectional analytical study. Place and Duration of Study: The Aga Khan University Hospital, Karachi, Pakistan, from May 2010 till January 2013. Methodology: Sonography of all breast nodules was done before and after exicision by two female radiologists with at least five years clinical experience. All surgeries were performed by the same referring breast surgeons. All nodules were non-palpable and had histopathology as well as specimen sonography performed at AKUH. Subjects were excluded, if histopathology was not available, post-procedure sonogram not done or done in another hospital and nodules that were not seen on ultrasound. After needle localization in 47 patients using ultrasound and in 7 patients using mammogram was done, sonogram was conducted in all 54 lesions. These were then assessed by ultrasound for detection of lesion and tumor-free margins in malignant lesion. Post-excision ultrasound was performed for the evaluation of lesion whether visualized or absent with localizing needle in situ, lesion dimensions, depth measurement between the superior margin of the lesion and its edge. Results: All 54 lesions were present on post-exicison scan, out of which 28 were documented as malignant and 26 as benign. Ultrasound declared all specimens as tumor-free. On histopathology, two lesions were documented as having tumor-positive margins and were proven to be invasive lobular carcinoma. Therefore, the negative predictive value of the specimen sonography for margin detection was 26/28 (92.8%). Conclusion: Ultrasound of the excised breast tumor specimen is a simple and reliable technique for confirmation of the tumor-free margins in non-palpable breast lesions. (author)

  4. Role of 3D power Doppler ultrasound in the further characterization of suspicious breast masses.

    Science.gov (United States)

    Kupeli, Ali; Kul, Sibel; Eyuboglu, Ilker; Oguz, Sukru; Mungan, Sevdegul

    2016-01-01

    To investigate effectiveness of vascular indices obtained with 3D power Doppler ultrasound in the further characterization of breast masses and prevention of unnecessary biopsies. Between April 2013 and March 2014, 109 patients (age range, 17-85 years; mean age, 47 years) with 117 radiologically or clinically suspicious breast masses were prospectively evaluated with 3DPDUS before biopsy. Mass volume (MV), vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were calculated using Virtual Organ Computer-aided Analysis (VOCAL) software and they were correlated with the final diagnosis. Cutoff values of vascular indices were determinated and diagnostic efficacy was calculated with receiver operating curve (ROC) analysis. All vascular indices, age of patients and tumor volume were significantly lower in benign masses compared with malignant ones (p<0.001). AUCs were 0.872, 0.867 and 0.789 for VI, VFI and FI, respectively. The diagnostic efficacy of VI (for cutoff 1.1; 83% sensitivity, 82% specificity and 82% accuracy) and VFI (for cutoff 0.4; 80% sensitivity, 83% specificity and 80% accuracy) were significantly higher than FI (for cutoff 33,9; 73% sensitivity, 69% specificity and 71% accuracy). It was found that with the use of vascular indices of 3DPDUS in the further characterization of suspicious breast masses between 24% to 37% of unnecessary biopsies could have been avoided. The vascular indices obtained with 3DPDUS seem reliable in the further characterization of suspicious breast masses and might be used to decrease unnecessary biopsies. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?

    Science.gov (United States)

    Lee, Eun Jung; Jung, Hae Kyoung; Ko, Kyung Hee; Lee, Jong Tae; Yoon, Jung Hyun

    2013-07-01

    To evaluate which shear wave elastography (SWE) parameter proves most accurate in the differential diagnosis of solid breast masses. One hundred and fifty-six breast lesions in 139 consecutive women (mean age: 43.54 ± 9.94 years, range 21-88 years), who had been scheduled for ultrasound-guided breast biopsy, were included. Conventional ultrasound and SWE were performed in all women before biopsy procedures. Ultrasound BI-RADS final assessment and SWE parameters were recorded. Diagnostic performance of each SWE parameter was calculated and compared with those obtained when applying cut-off values of previously published data. Performance of conventional ultrasound and ultrasound combined with each parameter was also compared. Of the 156 breast masses, 120 (76.9 %) were benign and 36 (23.1 %) malignant. Maximum stiffness (Emax) with a cut-off of 82.3 kPa had the highest area under the receiver operating characteristics curve (Az) value compared with other SWE parameters, 0.860 (sensitivity 88.9 %, specificity 77.5 %, accuracy 80.1 %). Az values of conventional ultrasound combined with each SWE parameter showed lower (but not significantly) values than with conventional ultrasound alone. Maximum stiffness (82.3 kPa) provided the best diagnostic performance. However the overall diagnostic performance of ultrasound plus SWE was not significantly better than that of conventional ultrasound alone. • SWE offers new information over and above conventional breast ultrasound • Various SWE parameters were explored regarding distinction between benign and malignant lesions • An elasticity of 82.3 kPa appears optimal in differentiating solid breast masses • However, ultrasound plus SWE was not significantly better than conventional ultrasound alone.

  6. The role of second-look ultrasound of BIRADS-3 mammary lesions detected by breast MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fiaschetti, V., E-mail: fiaschettivaleria@tin.it [Department of Imaging Diagnostic, Molecular Imaging, Interventional Radiology and Radiation Therapy University Hospital ' Tor Vergata' , 81 Oxford street, 00133 Rome (Italy); Salimbeni, C.; Gaspari, E.; Dembele, G. Kabunda; Bolacchi, F.; Cossu, E.; Pistolese, C.A.; Perretta, T.; Simonetti, G. [Department of Imaging Diagnostic, Molecular Imaging, Interventional Radiology and Radiation Therapy University Hospital ' Tor Vergata' , 81 Oxford street, 00133 Rome (Italy)

    2012-11-15

    Objective: To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI). Materials and methods: From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2). The clinical impact of second-look US was studied in terms of negative predictive value (NPV). Results: The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05). Conclusions: The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.

  7. The role of second-look ultrasound of BIRADS-3 mammary lesions detected by breast MR imaging

    International Nuclear Information System (INIS)

    Fiaschetti, V.; Salimbeni, C.; Gaspari, E.; Dembele, G. Kabunda; Bolacchi, F.; Cossu, E.; Pistolese, C.A.; Perretta, T.; Simonetti, G.

    2012-01-01

    Objective: To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI). Materials and methods: From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2). The clinical impact of second-look US was studied in terms of negative predictive value (NPV). Results: The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05). Conclusions: The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.

  8. A case-oriented web-based training system for breast cancer diagnosis.

    Science.gov (United States)

    Huang, Qinghua; Huang, Xianhai; Liu, Longzhong; Lin, Yidi; Long, Xingzhang; Li, Xuelong

    2018-03-01

    Breast cancer is still considered as the most common form of cancer as well as the leading causes of cancer deaths among women all over the world. We aim to provide a web-based breast ultrasound database for online training inexperienced radiologists and giving computer-assisted diagnostic information for detection and classification of the breast tumor. We introduce a web database which stores breast ultrasound images from breast cancer patients as well as their diagnostic information. A web-based training system using a feature scoring scheme based on Breast Imaging Reporting and Data System (BI-RADS) US lexicon was designed. A computer-aided diagnosis (CAD) subsystem was developed to assist the radiologists to make scores on the BI-RADS features for an input case. The training system possesses 1669 scored cases, where 412 cases are benign and 1257 cases are malignant. It was tested by 31 users including 12 interns, 11 junior radiologists, and 8 experienced senior radiologists. This online training system automatically creates case-based exercises to train and guide the newly employed or resident radiologists for the diagnosis of breast cancer using breast ultrasound images based on the BI-RADS. After the trainings, the interns and junior radiologists show significant improvement in the diagnosis of the breast tumor with ultrasound imaging (p-value  .05). The online training system can improve the capabilities of early-career radiologists in distinguishing between the benign and malignant lesions and reduce the misdiagnosis of breast cancer in a quick, convenient and effective manner. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  9. 3D quantitative breast ultrasound analysis for differentiating fibroadenomas and carcinomas smaller than 1 cm

    Energy Technology Data Exchange (ETDEWEB)

    Meel-van den Abeelen, A.S.S., E-mail: aisha.vandenabeelen@radboudumc.nl [Department of Biomechanical Engineering, MIRA-Institute, University of Twente, P.O. Box 217, 7500 AE Enschede (Netherlands); Medical UltraSound Imaging Center (MUSIC), department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500 HB Nijmegen (Netherlands); Weijers, G. [Medical UltraSound Imaging Center (MUSIC), department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500 HB Nijmegen (Netherlands); Zelst, J.C.M. van [Radboud University Nijmegen Medical Centre, Department of Radiology and Nuclear Medicine, PO Box 9101, 6500 HB Nijmegen (Netherlands); Thijssen, J.M. [Medical UltraSound Imaging Center (MUSIC), department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500 HB Nijmegen (Netherlands); Mann, R.M. [Radboud University Nijmegen Medical Centre, Department of Radiology and Nuclear Medicine, PO Box 9101, 6500 HB Nijmegen (Netherlands); Korte, C.L. de [Medical UltraSound Imaging Center (MUSIC), department of Radiology and Nuclear Medicine, Radboud University Medical Center, P.O. Box 9101, 6500 HB Nijmegen (Netherlands)

    2017-03-15

    Purpose: In (3D) ultrasound, accurate discrimination of small solid masses is difficult, resulting in a high frequency of biopsies for benign lesions. In this study, we investigate whether 3D quantitative breast ultrasound (3DQBUS) analysis can be used for improving non-invasive discrimination between benign and malignant lesions. Methods and materials: 3D US studies of 112 biopsied solid breast lesions (size <1 cm), were included (34 fibroadenomas and 78 invasive ductal carcinomas). The lesions were manually delineated and, based on sonographic criteria used by radiologists, 3 regions of interest were defined in 3D for analysis: ROI (ellipsoid covering the inside of the lesion), PER (peritumoural surrounding: 0.5 mm around the lesion), and POS (posterior-tumoural acoustic phenomena: region below the lesion with the same size as delineated for the lesion). After automatic gain correction (AGC), the mean and standard deviation of the echo level within the regions were calculated. For the ROI and POS also the residual attenuation coefficient was estimated in decibel per cm [dB/cm]. The resulting eight features were used for classification of the lesions by a logistic regression analysis. The classification accuracy was evaluated by leave-one-out cross-validation. Receiver operating characteristic (ROC) curves were constructed to assess the performance of the classification. All lesions were delineated by two readers and results were compared to assess the effect of the manual delineation. Results: The area under the ROC curve was 0.86 for both readers. At 100% sensitivity, a specificity of 26% and 50% was achieved for reader 1 and 2, respectively. Inter-reader variability in lesion delineation was marginal and did not affect the accuracy of the technique. The area under the ROC curve of 0.86 was reached for the second reader when the results of the first reader were used as training set yielding a sensitivity of 100% and a specificity of 40%. Consequently, 3DQBUS

  10. 3D quantitative breast ultrasound analysis for differentiating fibroadenomas and carcinomas smaller than 1 cm

    International Nuclear Information System (INIS)

    Meel-van den Abeelen, A.S.S.; Weijers, G.; Zelst, J.C.M. van; Thijssen, J.M.; Mann, R.M.; Korte, C.L. de

    2017-01-01

    Purpose: In (3D) ultrasound, accurate discrimination of small solid masses is difficult, resulting in a high frequency of biopsies for benign lesions. In this study, we investigate whether 3D quantitative breast ultrasound (3DQBUS) analysis can be used for improving non-invasive discrimination between benign and malignant lesions. Methods and materials: 3D US studies of 112 biopsied solid breast lesions (size <1 cm), were included (34 fibroadenomas and 78 invasive ductal carcinomas). The lesions were manually delineated and, based on sonographic criteria used by radiologists, 3 regions of interest were defined in 3D for analysis: ROI (ellipsoid covering the inside of the lesion), PER (peritumoural surrounding: 0.5 mm around the lesion), and POS (posterior-tumoural acoustic phenomena: region below the lesion with the same size as delineated for the lesion). After automatic gain correction (AGC), the mean and standard deviation of the echo level within the regions were calculated. For the ROI and POS also the residual attenuation coefficient was estimated in decibel per cm [dB/cm]. The resulting eight features were used for classification of the lesions by a logistic regression analysis. The classification accuracy was evaluated by leave-one-out cross-validation. Receiver operating characteristic (ROC) curves were constructed to assess the performance of the classification. All lesions were delineated by two readers and results were compared to assess the effect of the manual delineation. Results: The area under the ROC curve was 0.86 for both readers. At 100% sensitivity, a specificity of 26% and 50% was achieved for reader 1 and 2, respectively. Inter-reader variability in lesion delineation was marginal and did not affect the accuracy of the technique. The area under the ROC curve of 0.86 was reached for the second reader when the results of the first reader were used as training set yielding a sensitivity of 100% and a specificity of 40%. Consequently, 3DQBUS

  11. PDGF-AB rich-trombocyte lysate supplementation from breast cancer patients increased the proliferation of breast cancer stem cells

    Directory of Open Access Journals (Sweden)

    Wiwi A. Kartolo

    2018-05-01

    Full Text Available Background: Thrombocytosis in breast cancer (BC patient was thought to play a role in the invasiveness of breast cancer stem cells (BCSCs. Modification of tumor microenvironment was proposed to increase the efficacy of anticancer therapy. This study was aimed to analyze the effect of platelet lysate (PL as well as its PDGF-AB content as a tumor microenvironment on (CD24-/CD44+ BCSC proliferation.Methods: This was an experimental study that treated culture of BCSCs with PL from breast cancer (BC patients or healthy donors. Venous blood from all subjects were subjected to prior hematology test and then processed to obtain platelet rich plasma  (PRP. Platelet counts in PRP were determined. PRP was processed to obtain PL. PDGF-AB contents in PL were measured. PL at concentrations of 0.01% (v/v was supplemented into DMEM-F12 medium and used for culturing BCSCs (CD24-/CD44+ cells. After 48 hours, total cell count, population doubling time (PDT, and cell viability were calculated and their correlation with platelet count and PDGF-AB levels were analyzed.Results: BC patients (n=5 had higher platelet counts and PDGF-AB levels in PL compared to healthy donors (n=15, (p=0.02. PL from BC patients could stimulate the proliferation of BCSCs higher than healthy donors (p<0.001 and showed lower PDT value (p=0.001. Cell proliferation and PDT showed strong correlation with PDGF-AB level. This observation suggests that PDGF-AB has a role on BCSCs proliferation. PL showed no effect on BCSCs viability.Conclusion: Breast cancer patient platelet lysate stimulated BCSC proliferation.

  12. Breast Camps for Awareness and Early Diagnosis of Breast Cancer in Countries With Limited Resources: A Multidisciplinary Model From Kenya.

    Science.gov (United States)

    Sayed, Shahin; Moloo, Zahir; Ngugi, Anthony; Allidina, Amyn; Ndumia, Rose; Mutuiri, Anderson; Wasike, Ronald; Wahome, Charles; Abdihakin, Mohamed; Kasmani, Riaz; Spears, Carol D; Oigara, Raymond; Mwachiro, Elizabeth B; Busarla, Satya V P; Kibor, Kibet; Ahmed, Abdulaziz; Wawire, Jonathan; Sherman, Omar; Saleh, Mansoor; Zujewski, Jo Anne; Dawsey, Sanford M

    2016-09-01

    Breast cancer is the most common cancer of women in Kenya. There are no national breast cancer early diagnosis programs in Kenya. The objective was to conduct a pilot breast cancer awareness and diagnosis program at three different types of facilities in Kenya. This program was conducted at a not-for-profit private hospital, a faith-based public hospital, and a government public referral hospital. Women aged 15 years and older were invited. Demographic, risk factor, knowledge, attitudes, and screening practice data were collected. Breast health information was delivered, and clinical breast examinations (CBEs) were performed. When appropriate, ultrasound imaging, fine-needle aspirate (FNA) diagnoses, core biopsies, and onward referrals were provided. A total of 1,094 women were enrolled in the three breast camps. Of those, 56% knew the symptoms and signs of breast cancer, 44% knew how breast cancer was diagnosed, 37% performed regular breast self-exams, and 7% had a mammogram or breast ultrasound in the past year. Of the 1,094 women enrolled, 246 (23%) had previously noticed a lump in their breast. A total of 157 participants (14%) had abnormal CBEs, of whom 111 had ultrasound exams, 65 had FNAs, and 18 had core biopsies. A total of 14 invasive breast cancers and 1 malignant phyllodes tumor were diagnosed Conducting a multidisciplinary breast camp awareness and early diagnosis program is feasible in different types of health facilities within a low- and middle-income country setting. This can be a model for breast cancer awareness and point-of-care diagnosis in countries with limited resources like Kenya. This work describes a novel breast cancer awareness and early diagnosis demonstration program in a low- and middle-income country within a limited resource setting. The program includes breast self-awareness and breast cancer education, clinical exams, and point-of-care diagnostics for women in three different types of health facilities in Kenya. This pilot

  13. Selective determination of inorganic cobalt in nutritional supplements by ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction and electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Berton, Paula; Martinis, Estefanía M.; Martinez, Luis D.; Wuilloud, Rodolfo G.

    2012-01-01

    Highlights: ► Synergy of ultrasound energy and TILDLME technique for improved metal extraction. ► Highly selective determination of inorganic Co species at trace levels. ► Speciation analysis of Co in several nutritional supplements with highly complex matrices. ► Development of an environmentally friendly microextraction technique with minimal waste production and sample consumption. - Abstract: In the present work, a simple and rapid analytical method based on application of ionic liquids (ILs) for inorganic Co(II) species (iCo) microextraction in a variety of nutrient supplements was developed. Inorganic Co was initially chelated with 1-nitroso-2-naphtol (1N2N) reagent followed by a modern technique named ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction (USA-TILDLME). The extraction was performed with 1-hexyl-3-methylimidazolium hexafluorophosphate [C 6 mim][PF 6 ] with the aid of ultrasound to improve iCo recovery. Finally, the iCo-enriched IL phase was solubilized in methanol and directly injected into an electrothermal atomic absorption spectrometer (ETAAS). Several parameters that could influence iCo microextraction and detection were carefully studied. Since the main difficulty in these samples is caused by high concentrations of potential interfering ions, different approaches were evaluated to eliminate interferences. The limit of detection (LOD) was 5.4 ng L −1 , while the relative standard deviation (RSD) was 4.7% (at 0.5 μg L −1 Co level and n = 10), calculated from the peak height of absorbance signals. Selective microextraction of iCo species was achieved only by controlling the pH value during the procedure. The method was thus successfully applied for determination of iCo species in nutritional supplements.

  14. Selective determination of inorganic cobalt in nutritional supplements by ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction and electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Berton, Paula; Martinis, Estefania M. [Analytical Chemistry Research and Development Group (QUIANID), (LISAMEN-CCT-CONICET-Mendoza), Av. Ruiz Leal S/N Parque General San Martin, M 5502 IRA Mendoza (Argentina); Martinez, Luis D. [INQUISAL-CONICET, Departamento de Quimica Analitica, Facultad de Quimica, Bioquimica y Farmacia, Universidad Nacional de San Luis, San Luis (Argentina); Wuilloud, Rodolfo G., E-mail: rwuilloud@mendoza-conicet.gob.ar [Analytical Chemistry Research and Development Group (QUIANID), (LISAMEN-CCT-CONICET-Mendoza), Av. Ruiz Leal S/N Parque General San Martin, M 5502 IRA Mendoza (Argentina); Instituto de Ciencias Basicas, Universidad Nacional de Cuyo, Mendoza (Argentina)

    2012-02-03

    Highlights: Black-Right-Pointing-Pointer Synergy of ultrasound energy and TILDLME technique for improved metal extraction. Black-Right-Pointing-Pointer Highly selective determination of inorganic Co species at trace levels. Black-Right-Pointing-Pointer Speciation analysis of Co in several nutritional supplements with highly complex matrices. Black-Right-Pointing-Pointer Development of an environmentally friendly microextraction technique with minimal waste production and sample consumption. - Abstract: In the present work, a simple and rapid analytical method based on application of ionic liquids (ILs) for inorganic Co(II) species (iCo) microextraction in a variety of nutrient supplements was developed. Inorganic Co was initially chelated with 1-nitroso-2-naphtol (1N2N) reagent followed by a modern technique named ultrasound-assisted temperature-controlled ionic liquid dispersive liquid phase microextraction (USA-TILDLME). The extraction was performed with 1-hexyl-3-methylimidazolium hexafluorophosphate [C{sub 6}mim][PF{sub 6}] with the aid of ultrasound to improve iCo recovery. Finally, the iCo-enriched IL phase was solubilized in methanol and directly injected into an electrothermal atomic absorption spectrometer (ETAAS). Several parameters that could influence iCo microextraction and detection were carefully studied. Since the main difficulty in these samples is caused by high concentrations of potential interfering ions, different approaches were evaluated to eliminate interferences. The limit of detection (LOD) was 5.4 ng L{sup -1}, while the relative standard deviation (RSD) was 4.7% (at 0.5 {mu}g L{sup -1} Co level and n = 10), calculated from the peak height of absorbance signals. Selective microextraction of iCo species was achieved only by controlling the pH value during the procedure. The method was thus successfully applied for determination of iCo species in nutritional supplements.

  15. Breast cancer imaging

    International Nuclear Information System (INIS)

    Funke, M.; Villena, C.

    2008-01-01

    Advances in female breast imaging have substantially influenced the diagnosis, therapy, and prognosis of breast cancer in the past few years. Mammography using conventional or digital technique is considered the gold standard for the early detection of breast cancer. Other modalities such as breast ultrasound and contrast-enhanced magnetic resonance imaging of the breast play an important role in diagnostic imaging, staging, and follow-up of breast cancer. Percutaneous needle biopsy is a faster, less invasive, and more cost-effective method than surgical biopsy for verifying the histological diagnosis. New methods such as breast tomosynthesis, contrast-enhanced mammography, and positron emission tomography promise to further improve breast imaging. Further studies are mandatory to adapt these new methods to clinical needs and to evaluate their performance in clinical practice. (orig.) [de

  16. Ultrasound-Guided Optical Tomographic Imaging of Malignant and Benign Breast Lesions: Initial Clinical Results of 19 Cases1

    Science.gov (United States)

    Zhu, Quing; Huang, Minming; Chen, NanGuang; Zarfos, Kristen; Jagjivan, Bipin; Kane, Mark; Hedge, Poornima; Kurtzman, H. Scott

    2003-01-01

    Abstract The diagnosis of solid benign and malignant tumors presents a unique challenge to all noninvasive imaging modalities. Ultrasound is used in conjunction with mammography to differentiate simple cysts from solid lesions. However, the overlapping appearances of benign and malignant lesions make ultrasound less useful in differentiating solid lesions, resulting in a large number of benign biopsies. Optical tomography using near-infrared diffused light has great potential for imaging functional parameters of 1) tumor hemoglobin concentration, 2) oxygen saturation, and 3) metabolism, as well as other tumor distinguishing characteristics. These parameters can differentiate benign from malignant lesions. However, optical tomography, when used alone, suffers from low spatial resolution and target localization uncertainty due to intensive light scattering. Our aim is to combine diffused light imaging with ultrasound in a novel way for the detection and diagnosis of solid lesions. Initial findings of two earlystage invasive carcinomas, one combined fibroadenoma and fibrocystic change with scattered foci of lobular neoplasia/lobular carcinoma in situ, and 16 benign lesions are reported in this paper. The invasive cancer cases reveal about two-fold greater total hemoglobin concentration (mean 119 µmol) than benign cases (mean 67 µmol), and suggest that the discrimination of benign and malignant breast lesions might be enhanced by this type of achievable optical quantification with ultrasound localization. Furthermore, the small invasive cancers are well localized and have wavelength-dependent appearance in optical absorption maps, whereas the benign lesions appear diffused and relatively wavelength-independent. PMID:14670175

  17. Assessing tumor extent on contrast-enhanced spectral mammography versus full-field digital mammography and ultrasound.

    Science.gov (United States)

    Patel, Bhavika K; Garza, Sandra Alheli; Eversman, Sarah; Lopez-Alvarez, Yania; Kosiorek, Heidi; Pockaj, Barbara A

    To compare breast cancer size measurements on full-field digital mammography (FFDM), contrast-enhanced spectral mammography (CEDM), and ultrasound (US), with histologic tumor size used as the reference standard. Material and methods The HIPAA complaint, IRB approved study comprised 88 women with newly diagnosed breast cancer who underwent FFDM and CEDM;74 also had US. Breast density, histologic subtype, and maximum tumor measurements were recorded. Pearson correlation coefficients for FFDM, US, and CEDM vs histopathology were 0.598, 0.639, and 0.859, respectively (P<0.001). The following correlation coefficients were calculated for dense breasts (n=48): histopathology vs FFDM (0.555), US (0.633), and CEDM (0.843) (P<0.001); for nondense breasts (n=40), they were FFDM (0.618), US (0.512), and CEDM (0.885) (P<0.001). For size difference, the mean (SD) for histopathology vs FFDM, US, and CEDM was -1.3 (11.9) mm, -2.8 (11.1) mm, and 2.9 (9.5) mm, respectively. Limits of agreement were -24.8 to 22.0mm, -24.5 to 18.8mm, and -15.6 to 21.4mm, respectively. In patients with biopsy-proven malignancy, size measurements correlated well with histopathologic size, and were higher on CEDM than those for FFDM and US in patients with dense or nondense breasts. The added value of CEDM as a supplement to FFDM in determining tumor size, however, was greater in patients with dense breasts. CEDM may be a promising alternative preoperative measurement tool for breast cancer patients with dense breasts and/or limited access or contraindications to MRI. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Comparing Performance of Combinations of Shear Wave Elastography and B-Mode Ultrasound in Diagnosing Breast Masses: Is It Influenced by Mass Size?

    Science.gov (United States)

    Cong, Rui; Li, Jing; Wang, Xuejiao

    2017-10-01

    We determined the diagnostic performance of combinations of shear wave elastography (SWE) and B-mode ultrasound (US) in differentiating malignant from benign breast masses, and we investigated whether performance is affected by mass size. In this prospective study of 315 consecutive patients with 326 breast masses, US and SWE were performed before biopsy. Masses were categorized into two subgroups on the basis of mass size (≤15 mm and >15 mm), and the optimal thresholds for the SWE parameters were determined for each subgroup using receiver operating characteristic curves. The combination proposed here achieved an area under the receiver operating characteristic curve of 0.943, 95.00% sensitivity and 81.18% specificity, which approximated the diagnostic performance of US alone. The performance of the combinations using the subgroups' thresholds did not differ significantly from those based on the entire study group's thresholds, but the optimal thresholds were higher in the subgroup of larger masses. Further research is needed to determine whether mass size affects the performance of combinations of SWE and US. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Determinants of the reliability of ultrasound tomography sound speed estimates as a surrogate for volumetric breast density

    Energy Technology Data Exchange (ETDEWEB)

    Khodr, Zeina G.; Pfeiffer, Ruth M.; Gierach, Gretchen L., E-mail: GierachG@mail.nih.gov [Department of Health and Human Services, Division of Cancer Epidemiology and Genetics, National Cancer Institute, 9609 Medical Center Drive MSC 9774, Bethesda, Maryland 20892 (United States); Sak, Mark A.; Bey-Knight, Lisa [Karmanos Cancer Institute, Wayne State University, 4100 John R, Detroit, Michigan 48201 (United States); Duric, Nebojsa; Littrup, Peter [Karmanos Cancer Institute, Wayne State University, 4100 John R, Detroit, Michigan 48201 and Delphinus Medical Technologies, 46701 Commerce Center Drive, Plymouth, Michigan 48170 (United States); Ali, Haythem; Vallieres, Patricia [Henry Ford Health System, 2799 W Grand Boulevard, Detroit, Michigan 48202 (United States); Sherman, Mark E. [Division of Cancer Prevention, National Cancer Institute, Department of Health and Human Services, 9609 Medical Center Drive MSC 9774, Bethesda, Maryland 20892 (United States)

    2015-10-15

    Purpose: High breast density, as measured by mammography, is associated with increased breast cancer risk, but standard methods of assessment have limitations including 2D representation of breast tissue, distortion due to breast compression, and use of ionizing radiation. Ultrasound tomography (UST) is a novel imaging method that averts these limitations and uses sound speed measures rather than x-ray imaging to estimate breast density. The authors evaluated the reproducibility of measures of speed of sound and changes in this parameter using UST. Methods: One experienced and five newly trained raters measured sound speed in serial UST scans for 22 women (two scans per person) to assess inter-rater reliability. Intrarater reliability was assessed for four raters. A random effects model was used to calculate the percent variation in sound speed and change in sound speed attributable to subject, scan, rater, and repeat reads. The authors estimated the intraclass correlation coefficients (ICCs) for these measures based on data from the authors’ experienced rater. Results: Median (range) time between baseline and follow-up UST scans was five (1–13) months. Contributions of factors to sound speed variance were differences between subjects (86.0%), baseline versus follow-up scans (7.5%), inter-rater evaluations (1.1%), and intrarater reproducibility (∼0%). When evaluating change in sound speed between scans, 2.7% and ∼0% of variation were attributed to inter- and intrarater variation, respectively. For the experienced rater’s repeat reads, agreement for sound speed was excellent (ICC = 93.4%) and for change in sound speed substantial (ICC = 70.4%), indicating very good reproducibility of these measures. Conclusions: UST provided highly reproducible sound speed measurements, which reflect breast density, suggesting that UST has utility in sensitively assessing change in density.

  20. MO-A-BRD-01: An Investigation of the Dynamic Response of a Novel Acousto-Optic Liquid Crystal Detector for Full-Field Transmission Ultrasound Breast Imaging

    International Nuclear Information System (INIS)

    Rosenfield, J.R.; La Riviere, P.J.; Sandhu, J.S.

    2014-01-01

    Purpose: To characterize the dynamic response of a novel acousto-optic (AO) liquid crystal detector for high-resolution transmission ultrasound breast imaging. Transient and steady-state lesion contrast were investigated to identify optimal transducer settings for our prototype imaging system consistent with the FDA limits of 1 W/cm 2 and 50 J/cm 2 on the incident acoustic intensity and the transmitted acoustic energy flux density. Methods: We have developed a full-field transmission ultrasound breast imaging system that uses monochromatic plane-wave illumination to acquire projection images of the compressed breast. The acoustic intensity transmitted through the breast is converted into a visual image by a proprietary liquid crystal detector operating on the basis of the AO effect. The dynamic response of the AO detector in the absence of an imaged breast was recorded by a CCD camera as a function of the acoustic field intensity and the detector exposure time. Additionally, a stereotactic needle biopsy breast phantom was used to investigate the change in opaque lesion contrast with increasing exposure time for a range of incident acoustic field intensities. Results: Using transducer voltages between 0.3 V and 0.8 V and exposure times of 3 minutes, a unique one-to-one mapping of incident acoustic intensity to steady-state optical brightness in the AO detector was observed. A transfer curve mapping acoustic intensity to steady-state optical brightness shows a high-contrast region analogous to the linear portion of the Hurter-Driffield curves of radiography. Using transducer voltages between 1 V and 1.75 V and exposure times of 90 s, the lesion contrast study demonstrated increasing lesion contrast with increasing breast exposure time and acoustic field intensity. Lesion-to-background contrast on the order of 0.80 was observed. Conclusion: Maximal lesion contrast in our prototype system can be obtained using the highest acoustic field intensity and the longest breast

  1. Evaluation of breast symptoms with mammography and ultrasonography

    Directory of Open Access Journals (Sweden)

    Emine Devolli Disha

    2011-12-01

    Full Text Available Introduction: Aim of the study was to discern which are more frequent symptoms presented in malign and benign masses diagnosed by mammography and ultrasonography.Methods: Our study group consisted of 546 female patients, with breast symptoms such as palpable lumps (40.8%, pain in the breast (26%, localized lumpiness or nodularity (13.7%, nipple retraction (11.2%, nipplebloody discharge (5.1% and redness and swelling of the breast (3.1%. All 546 patients were examined by ultrasonography and mammography. Biopsy was performed according to the findings of mammography and ultrasonography.Results: In breast cancer detection ultrasonography showed an efficiency of 79.4% compared to 55.0% for mammography in detecting breast lump, in the case of nipple retraction mammography showed an efficiency of 89.1% compared to 80.4% for ultrasound, while the lowest efficiency for mammography was in the cases with localized lumpiness or nodularity 17.1% compared to 45.7% for ultrasound. In detecting fibrocystic changes where the most common symptoms was pain, ultrasonography showed an efficiency of 99.3 % compared to 84.2 % for mammography.Conclusions: Our study confirmed that breast lumps are detectable in the majority of patients with breast cancer. The most frequent symptoms in patient with benign lesions were pain or localized discomfort. The diagnostic accuracy for carcinomas of the breast and for benign lesions according to symptoms was higher for ultrasound than for mammography.

  2. Initial Experience with a Wireless Ultrasound-Guided Vacuum-Assisted Breast Biopsy Device.

    Directory of Open Access Journals (Sweden)

    E-Ryung Choi

    Full Text Available To determine the imaging characteristic of frequent target lesions of wireless ultrasound (US-guided, vacuum-assisted breast biopsy (Wi-UVAB and to evaluate diagnostic yield, accuracy and complication of the device in indeterminate breast lesions.From March 2013 to October 2014, 114 women (age range, 29-76 years; mean age, 50.0 years underwent Wi-UVAB using a 13-gauge needle (Mammotome Elite®; Devicor Medical Products, Cincinnati, OH, USA. In 103 lesions of 96 women with surgical (n = 81 or follow-up (n = 22 data, complications, biopsy procedure, imaging findings of biopsy targets and histologic results were reviewed.Mean number of biopsy cores was 10 (range 4-25. Nine patients developed moderate bleeding. All lesions were suspicious on US, and included non-mass lesions (67.0% and mass lesions (33.0%. Visible calcifications on US were evident in 57.3% of the target lesions. Most of the lesions (93.2% were nonpalpable. Sixty-six (64.1% were malignant [ductal carcinoma in situ (DCIS rate, 61%] and 12 were high-risk lesions (11.7%. Histologic underestimation was identified in 11 of 40 (27.5%. DCIS cases and in 3 of 9 (33.3% high-risk lesions necessitating surgery. There was no false-negative case.Wi-UVAB is very handy and advantageous for US-unapparent non-mass lesions to diagnose DCIS, especially for calcification cases. Histologic underestimation is unavoidable; still, Wi-UVAB is safe and accurate to diagnose a malignancy.

  3. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  4. Breast imaging with the SoftVue imaging system: first results

    Science.gov (United States)

    Duric, Neb; Littrup, Peter; Schmidt, Steven; Li, Cuiping; Roy, Olivier; Bey-Knight, Lisa; Janer, Roman; Kunz, Dave; Chen, Xiaoyang; Goll, Jeffrey; Wallen, Andrea; Zafar, Fouzaan; Allada, Veerendra; West, Erik; Jovanovic, Ivana; Li, Kuo; Greenway, William

    2013-03-01

    For women with dense breast tissue, who are at much higher risk for developing breast cancer, the performance of mammography is at its worst. Consequently, many early cancers go undetected when they are the most treatable. Improved cancer detection for women with dense breasts would decrease the proportion of breast cancers diagnosed at later stages, which would significantly lower the mortality rate. The emergence of whole breast ultrasound provides good performance for women with dense breast tissue, and may eliminate the current trade-off between the cost effectiveness of mammography and the imaging performance of more expensive systems such as magnetic resonance imaging. We report on the performance of SoftVue, a whole breast ultrasound imaging system, based on the principles of ultrasound tomography. SoftVue was developed by Delphinus Medical Technologies and builds on an early prototype developed at the Karmanos Cancer Institute. We present results from preliminary testing of the SoftVue system, performed both in the lab and in the clinic. These tests aimed to validate the expected improvements in image performance. Initial qualitative analyses showed major improvements in image quality, thereby validating the new imaging system design. Specifically, SoftVue's imaging performance was consistent across all breast density categories and had much better resolution and contrast. The implications of these results for clinical breast imaging are discussed and future work is described.

  5. [Ultrasound-assisted approach to blocking the intercostal nerves in the mid-axillary line for non-reconstructive breast and axilla surgery].

    Science.gov (United States)

    Diéguez García, P; Fajardo Pérez, M; López Álvarez, S; Alfaro de la Torre, P; Pensado Castiñeiras, A P

    2013-01-01

    Several nerve blocks have recently been used for pain treatment in breast surgery. The main objective of our study was to determine the efficacy and safety of ultrasound-assisted blocking of the anterior and lateral cutaneous branches of the intercostal nerves in the mid-axillary line for non-reconstructive breast and axilla surgery. A prospective observational study was conducted on 30 patients scheduled for non-reconstructive breast and axilla surgery. An intercostal branches block was performed in the mid-axillary line with 0,5% levobupivacaine (3ml in each intercostal space). Clinical efficacy was assessed by standard intraoperative hemodynamic response to surgical stimulus and the need for opioids, and in the postoperative period, by assessing pain intensity as a verbal numerical scale and the need for rescue treatment. We also evaluated the quality of sleep the first night after surgery, any adverse events that occurred, and the satisfaction of patients and surgeons with the anesthetic technique. The intercostal branches block in the mid-axillary line was effective in most cases, with only 2 patients requiring intraoperative opioids, and in one case analgesic rescue was necessary in the postoperative period. The duration of postoperative analgesia was 19±4h. There were no notable adverse events or complications. The satisfaction with the chosen technique was assessed as "very good" in all patients, and by 97% of the surgeons. Intercostal branches block in the mid-axillary line provides adequate intraoperative and postoperative analgesia for non-reconstructive breast and axilla surgery. It is a simple, reproducible technique in most patients of this study, with an easy to understand ultrasound anatomy, in which adequate analgesia could be provided through a single puncture, and may be an alternative to neuroaxial blocks. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights

  6. Effects of chromium-enriched bacillus subtilis KT260179 supplementation on chicken growth performance, plasma lipid parameters, tissue chromium levels, cecal bacterial composition and breast meat quality.

    Science.gov (United States)

    Yang, Jiajun; Qian, Kun; Zhang, Wei; Xu, Yayuan; Wu, Yijing

    2016-11-08

    Both chromium (Cr) and probiotic bacillus own the virtues of regulating animal metabolism and meat quality. Purpose of this study was to evaluate the efficiency of supplemental Cr and bacillus in the form of chromium-enriched Bacillus subtilis KT260179 (CEBS) on chicken growth performance, plasma lipid parameters, tissue chromium levels, cecal bacterial composition and breast meat quality. Six hundred of 1-day-old Chinese Huainan Partridge chickens were divided into four groups randomly: Control, inorganic Cr, Bacillus subtilis, and CEBS. The feed duration was 56 days. After 28 days of treatment, broiler feed CEBS or normal B. subtilis had higher body weights than control broiler, and after 56 days, chickens given either CEBS or B. subtilis had greater body weights than control broiler or those given inorganic Cr. Plasma total cholesterol, triglycerides, and low density lipoprotein cholesterol levels declined significantly in the CEBS group compared with the control, whereas plasma high density lipoprotein cholesterol levels increased significantly. The concentration of Cr in blood and breast muscle increased after CEBS and inorganic Cr supplementation. B. subtilis and CEBS supplementation caused a significant increase in the numbers of Lactobacillus and Bifidobacterium in the caecum, while the numbers of Escherichia coli and Salmonella decreased significantly compared to the control. Feed adding CEBS increased the lightness, redness, and yellowness of breast meat, improved the water-holding capacity, decreased the shear force and cooking loss. In all, CEBS supplementation promoted body growth, improved plasma lipid parameters, increased tissue Cr concentrations, altered cecal bacterial composition and improved breast meat quality.

  7. The role of cone-beam breast-CT for breast cancer detection relative to breast density.

    Science.gov (United States)

    Wienbeck, Susanne; Uhlig, Johannes; Luftner-Nagel, Susanne; Zapf, Antonia; Surov, Alexey; von Fintel, Eva; Stahnke, Vera; Lotz, Joachim; Fischer, Uwe

    2017-12-01

    To evaluate the impact of breast density on the diagnostic accuracy of non-contrast cone-beam breast computed tomography (CBBCT) in comparison to mammography for the detection of breast masses. A retrospective study was conducted from August 2015 to July 2016. Fifty-nine patients (65 breasts, 112 lesions) with BI-RADS, 5th edition 4 or 5 assessment in mammography and/or ultrasound of the breast received an additional non-contrast CBBCT. Independent double blind reading by two radiologists was performed for mammography and CBBCT imaging. Sensitivity, specificity and AUC were compared between the modalities. Breast lesions were histologically examined in 85 of 112 lesions (76%). The overall sensitivity for CBBCT (reader 1: 91%, reader 2: 88%) was higher than in mammography (both: 68%, pdensity group (pdensity breasts. • Overall sensitivity for non-contrast CBBCT ranged between 88%-91%. • Sensitivity was higher for CBBCT than mammography in both density types (pdensity types (pdensity types (p<0.001).

  8. Treatment of Murine Tumor Models of Breast Adenocarcinoma by Continuous Dual-Frequency Ultrasound

    Directory of Open Access Journals (Sweden)

    Amir Hoshang Barati

    2009-03-01

    Full Text Available Introduction: Acoustic transient cavitation is the primary mechanism of sonochemical reaction and has potential use for tumor treatment. In this study, the in vivo anti-tumor effect of simultaneous dual-frequency ultrasound at low-level intensity (ISATA < 6 W/cm2 was investigated in a spontaneous murine model of breast adenocarcinoma in Balb/c mice. Materials and Methods: Forty tumor bearing mice were divided into four groups (10 in each group. The treated groups received 15 or 30 minutes of combined dual-frequency ultrasound in continuous mode (1 MHzcon + 150 kHzcon respectively. The control and the sham groups contained the untreated mice. The tumor growth delay parameters including tumor volume, relative tumor volume, T5 and T2 (the needed time for each tumor to reach 5 and 2 times the initial tumor volume, respectively, survival period and percent of tumor growth inhibition ratio were measured on different days after treatment. Results: The results showed that the 30 min treatment was effective in tumor growth delay and percent of tumor growth inhibitory ratio compared to the sham and the control groups. The tumor volume growth and relative volume of tumors in the same treated group showed an anti-tumor effect relative to the sham and the control groups. There was a significant difference in tumor volume growth between this 30 min treatment group and the sham group 12 days after treatment (p-value

  9. Comparison the treatment effects between simultaneous dual frequency and single frequency irradiation of ultrasound in a murine model of breast adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Mahboobeh Alamolhoda

    2010-12-01

    Full Text Available Introduction: Transient cavitations induced by low frequency irradiation of ultrasound can be used to treat tumors. Previous studies in in-vitro experiments have shown that induced cavitation by dual or multiple frequencies of ultrasound is greater than induced cavitation by single frequency irradiation. In this study, we compared and evaluated the treatment effects of dual frequency irradiation of ultrasound (1 MHz and 150 kHz and single frequency irradiation in in-vivo experiments on breast adenocarcinoma tumors. Material and Method: In this study, the tumor-bearing mice were divided into 5 groups: control, sham, treated group for 30 min with 150 kHz frequency in continuous mode, another group with 1 MHz frequency in pulse mode, and treated group with combined dual frequency ultrasound (150 kHz in continuous mode and 1 MHz in 80% pulse mode. To evaluate the effects of ultrasound irradiation on tumor growth delay, the volumes of the tumors were investigated for 30 days. Tumor growth delay parameters including relative volume, inhibition ratio percentage and the required times for the tumor volume to reach to two (T2 and five (T5 times its initial volume were calculated. Results: The results showed that the treated groups with single frequency irradiation of 150 kHz continuous mode and 1 MHz pulse mode and combined dual frequency had statistically significant differences in tumor relative volume percentage during the period of 3 to 24 days after treatment (p

  10. SOUND-SPEED TOMOGRAPHY USING FIRST-ARRIVAL TRANSMISSION ULTRASOUND FOR A RING ARRAY

    Energy Technology Data Exchange (ETDEWEB)

    HUANG, LIANJIE [Los Alamos National Laboratory; QUAN, YOULI [Los Alamos National Laboratory

    2007-01-31

    Sound-speed tomography images can be used for cancer detection and diagnosis. Tumors have generally higher sound speeds than the surrounding tissue. Quality and resolution of tomography images are primarily determined by the insonification/illumination aperture of ultrasound and the capability of the tomography method for accurately handling heterogeneous nature of the breast. We investigate the capability of an efficient time-of-flight tomography method using transmission ultrasound from a ring array for reconstructing sound-speed images of the breast. The method uses first arrival times of transmitted ultrasonic signals emerging from non-beamforming ultrasound transducers located around a ring. It properly accounts for ray bending within the breast by solving the eikonal equation using a finite-difference scheme. We test and validate the time-of-flight transmission tomography method using synthetic data for numerical breast phantoms containing various objects. In our simulation, the objects are immersed in water within a ring array. Two-dimensional synthetic data are generated using a finite-difference scheme to solve acoustic-wave equation in heterogeneous media. We study the reconstruction accuracy of the tomography method for objects with different sizes and shapes as well as different perturbations from the surrounding medium. In addition, we also address some specific data processing issues related to the tomography. Our tomography results demonstrate that the first-arrival transmission tomography method can accurately reconstruct objects larger than approximately five wavelengths of the incident ultrasound using a ring array.

  11. Endoscopic Ultrasound Elastography: Current Clinical Use in Pancreas.

    Science.gov (United States)

    Mondal, Utpal; Henkes, Nichole; Patel, Sandeep; Rosenkranz, Laura

    2016-08-01

    Elastography is a newer technique for the assessment of tissue elasticity using ultrasound. Cancerous tissue is known to be stiffer (hence, less elastic) than corresponding healthy tissue, and as a result, could be identified in an elasticity-based imaging. Ultrasound elastography has been used in the breast, thyroid, and cervix to differentiate malignant from benign neoplasms and to guide or avoid unnecessary biopsies. In the liver, elastography has enabled a noninvasive and reliable estimate of fibrosis. Endoscopic ultrasound has become a robust diagnostic and therapeutic tool for the management of pancreatic diseases. The addition of elastography to endoscopic ultrasound enabled further characterization of pancreas lesions, and several European and Asian studies have reported encouraging results. The current clinical role of endoscopic ultrasound elastography in the management of pancreas disorders and related literature are reviewed.

  12. Ultrasound guided fine needle aspiration cytology versus core biopsy in the preoperative assessment of non-palpable breast lesions

    International Nuclear Information System (INIS)

    Ahmed, M.E.; Ahmad, I.

    2010-01-01

    Background: Breast screening is a method of detecting breast cancer at a very early stage. Most of the lesions detected by screening are not malignant. Objective of this study was to compare ultrasound guided fine needle aspiration cytology and core biopsy in the preoperative assessment of non-palpable breast lesions. Methods: The study was conducted prospectively at Department of Radiology, Shaukat Khanum Memorial Cancer Hospital and Research Centre, Pakistan from March 2004 to February 2005. All the patients underwent fine needle aspiration cytology and core biopsy. Later on, all of them had excision biopsy/ mastectomy. Prospectively 80 patients were studied; information was collected on a specifically designed form according to inclusion criteria. The patient age, sex, medical record number and side of lesion were recorded. Clinical history of duration of lump was also taken. Informed consent was obtained. Results: The age of patients were ranges from 20-71 years, with mean of 44.31+- 11.002 and the maximum number of patients 28 (35.3%) was between the ages 50 - 59 years. The sensitivity of FNAC was 92.85%, while the specificity of was 90% and the accuracy rate was 92.1%. The sensitivity of core biopsy was 94.64%, specificity 91.30% and accuracy rate was 94.87%. Conclusion: Fine Needle Aspiration has been found to be an extremely useful method for the diagnosis of lumps of breast. The accuracy and the sensitivity of diagnosis on fine needle aspiration cytology were high. (author)

  13. TH-A-18A-01: Innovation in Clinical Breast Imaging

    International Nuclear Information System (INIS)

    Liu, B; Yang, K; Yaffe, M; Chen, J

    2014-01-01

    Several novel modalities have been or are on the verge of being introduced into the breast imaging clinic. These include tomosynthesis imaging, dedicated breast CT, contrast-enhanced digital mammography, and automated breast ultrasound, all of which are covered in this course. Tomosynthesis and dedicated breast CT address the problem of tissue superimposition that limits mammography screening performance, by improved or full resolution of the 3D breast morphology. Contrast-enhanced digital mammography provides functional information that allows for visualization of tumor angiogenesis. 3D breast ultrasound has high sensitivity for tumor detection in dense breasts, but the imaging exam was traditionally performed by radiologists. In automated breast ultrasound, the scan is performed in an automated fashion, making for a more practical imaging tool, that is now used as an adjunct to digital mammography in breast cancer screening. This course will provide medical physicists with an in-depth understanding of the imaging physics of each of these four novel imaging techniques, as well as the rationale and implementation of QC procedures. Further, basic clinical applications and work flow issues will be discussed. Learning Objectives: To be able to describe the underlying physical and physiological principles of each imaging technique, and to understand the corresponding imaging acquisition process. To be able to describe the critical system components and their performance requirements. To understand the rationale and implementation of quality control procedures, as well as regulatory requirements for systems with FDA approval. To learn about clinical applications and understand risks and benefits/strength and weakness of each modality in terms of clinical breast imaging

  14. Ultrasound-guided drainage of subcutaneous abscesses on the trunk is feasible

    DEFF Research Database (Denmark)

    Kjær, Søren; Rud, Bo; Bay-Nielsen, Morten

    2013-01-01

    Subcutaneous trunk abscesses are frequent, and current treatment options generally involve incision. By contrast, the standard care for breast abcesses is ultrasound-guided drainage. The aim of this study was to evaluate the feasibility of ultrasound-guided drainage combined with antibiotics...... in the treatment of subcutaneous abscesses on the trunk....

  15. SU-E-I-53: Variation in Measurements of Breast Skin Thickness Obtained Using Different Imaging Modalities

    International Nuclear Information System (INIS)

    Nguyen, U; Kumaraswamy, N; Markey, M

    2014-01-01

    Purpose: To investigate variation in measurements of breast skin thickness obtained using different imaging modalities, including mammography, computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI). Methods: Breast skin thicknesses as measured by mammography, CT, ultrasound, and MRI were compared. Mammographic measurements of skin thickness were obtained from published studies that utilized standard positioning (upright) and compression. CT measurements of skin thickness were obtained from a published study of a prototype breast CT scanner in which the women were in the prone position and the breast was uncompressed. Dermatological ultrasound exams of the breast skin were conducted at our institution, with the subjects in the upright position and the breast uncompressed. Breast skin thickness was calculated from breast MRI exams at our institution, with the patient in the prone position and the breast uncompressed. Results: T tests for independent samples demonstrated significant differences in the mean breast skin thickness as measured by different imaging modalities. Repeated measures ANOVA revealed significant differences in breast skin thickness across different quadrants of the breast for some modalities. Conclusion: The measurement of breast skin thickness is significantly different across different imaging modalities. Differences in the amount of compression and differences in patient positioning are possible reasons why measurements of breast skin thickness vary by modality

  16. Evaluation of tomosynthesis elastography in a breast-mimicking phantom

    International Nuclear Information System (INIS)

    Engelken, Florian Jan; Sack, Ingolf; Klatt, Dieter; Fischer, Thomas; Fallenberg, Eva Maria; Bick, Ulrich; Diekmann, Felix

    2012-01-01

    Objective: To evaluate whether measurement of strain under static compression in tomosynthesis of a breast-mimicking phantom can be used to distinguish tumor-simulating lesions of different elasticities and to compare the results to values predicted by rheometric analysis as well as results of ultrasound elastography. Materials and methods: We prepared three soft breast-mimicking phantoms containing simulated tumors of different elasticities. The phantoms were imaged using a wide angle tomosynthesis system with increasing compression settings ranging from 0 N to 105 N in steps of 15 N. Strain of the inclusions was measured in two planes using a commercially available mammography workstation. The elasticity of the phantom matrix and inclusion material was determined by rheometric analysis. Ultrasound elastography of the inclusions was performed using two different ultrasound elastography algorithms. Results: Strain at maximal compression was 24.4%/24.5% in plane 1/plane 2, respectively, for the soft inclusion, 19.6%/16.9% for the intermediate inclusion, and 6.0%/10.2% for the firm inclusion. The strain ratios predicted by rheometrical testing were 0.41, 0.83 and 1.26 for the soft, intermediate, and firm inclusions, respectively. The strain ratios obtained for the soft, intermediate, and firm inclusions were 0.72 ± 0.13, 1.02 ± 0.21 and 2.67 ± 1.70, respectively for tomosynthesis elastography, 0.91, 1.64 and 2.07, respectively, for ultrasound tissue strain imaging, and 0.97, 2.06 and 2.37, respectively, for ultrasound real-time elastography. Conclusions: Differentiation of tumor-simulating inclusions by elasticity in a breast mimicking phantom may be possible by measuring strain in tomosynthesis. This method may be useful for assessing elasticity of breast lesions tomosynthesis of the breast

  17. Staging Investigations in Breast Cancer: Collective Opinion of UK Breast Surgeons

    Directory of Open Access Journals (Sweden)

    N. Chand

    2013-01-01

    Full Text Available Introduction. Certain clinicopathological factors are associated with a higher likelihood of distant metastases in primary breast cancer. However, there remains inconsistency in which patients undergo formal staging for distant metastasis and the most appropriate investigation(s. Aims. To identify UK surgeon preferences and practice with regard to staging investigations for distant metastases. Methods. A survey was disseminated to members of the Association of Breast Surgery by e-mail regarding surgeon/breast unit demographics, use of staging investigations, and local policy on pre/postoperative staging investigations. Several patient scenarios were also presented. Results. 123 of 474 (25.9% recipients completed the survey. Investigations routinely employed for patients diagnosed with early breast cancer included serological/haematological tests (72% respondents, axillary ultrasound (67%, liver ultrasound (2%, chest radiograph (36%, and computed tomography (CT (1%. Three areas contributed to decisions to undertake staging by CT scan: tumour size, axillary nodal status, and plan for chemotherapy. There was widespread variation as to criteria for CT staging based on tumour size and nodal status, as well as the choice of staging investigation for the clinical scenarios presented. Conclusions. There remains variation in the use of staging investigations for distant disease in early breastcancer despite available guidelines.

  18. Breast Imaging: How We Manage Diagnostic Technology at a Multidisciplinary Breast Center

    Directory of Open Access Journals (Sweden)

    Alejandro Tejerina Bernal

    2012-01-01

    Full Text Available This paper discusses the most important aspects and problems related to the management of breast cancer imaging, at a center specialized in breast pathology. We review the established and emerging diagnostic techniques, their indications, and peculiarities: digital mammography, CAD systems, and the recent digital breast tomosynthesis, ultrasound and complementary elastography, molecular imaging techniques, magnetic resonance imaging, advanced sequences (diffusion, and positron emission mammography (PEM. The adequate integration and rational management of these techniques is essential, but this is not always easy, in order to achieve a successful diagnosis.

  19. Breast Cancer Detection: Mammography and other methods in breast imaging, second edition

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.

    1987-01-01

    The text addresses mammography and the advantages and limitations of other breast imaging methods presently available. The establishment of X-ray mammography as the safest and most accurate noninvasive method of early, nonpalpable breast cancer detection is addressed in the first section of the book. The second section emphasizes the signs of early cancer, the complete mammographic examination, and the team approach to diagnosis. The advantages and limitations of film-screen mammography, zero mammography, breast ultrasound, thermography, light scanning, magnetic resonance imaging, and ductography are highlighted as alternate methods of detection. The benefits of mammography, and its unmatched value in screeening for breast cancer, are presented in the final section

  20. Case study: Solitary intra-cystic papilloma - Advances in consultant radiographic practitioner led ultrasound guided mammotome excisional biopsy

    International Nuclear Information System (INIS)

    Lawson, Sarah

    2008-01-01

    Working practices in Breast Radiology have changed and advanced in the past few years, resulting in an increase in the number of small, indeterminate, non-palpable breast lesions detected. One such lesion is the breast papillary lesion which is essentially an epithelial proliferation with an associate increased risk of breast carcinoma. The current management of an intra-cystic breast papilloma diagnosed by 14 g core biopsy is highly contentious as traditionally management is by surgical biopsy. Recent advances have demonstrated that excision by 8 or 11-gauge Ultrasound guided Mammotomy can be a safe alternative, allowing non-operative removal. The consultant radiographic practitioner role has been integral in establishing the policies needed to support and establish ultrasound guided Mammotome excisional biopsy

  1. Effect of protein-xanthophylls (PX) concentrate of alfalfa supplementation on physico-chemical properties of turkey breast and thigh muscles during ageing.

    Science.gov (United States)

    Karwowska, M; Stadnik, J; Dolatowski, Z J; Grela, E R

    2010-10-01

    The objective was to evaluate the effects of a dietary protein-xanthophylls (PX) concentrate of alfalfa to turkey diets (at 15 and 30 g kg(-1) feed) on the physico-chemical properties of breast and thigh muscles during ageing. The experiment involved 120 turkeys (Big-6 type) allotted to 3 groups (group I-control group; group II--with 1.5% supplementation of the protein-xanthophylls (PX) concentrate; group III--with 3% supplementation of the protein-xanthophylls (PX) concentrate). Measurements of pH, water holding capacity, color, oxymyoglobin content, TBARS and oxidation-reduction potential showed that the addition of protein-xanthophylls (PX) concentrate of alfalfa to a turkey diet did not cause deterioration of breast and thigh meat quality. In addition, changes in color, oxymyoglobin content, TBARS and oxidation-reduction potential values suggested that the inclusion of the concentrate to turkey diets acts as an antioxidant in the raw meat. Copyright (c) 2010 The American Meat Science Association. Published by Elsevier Ltd. All rights reserved.

  2. Impact on Clinical Management of After-Hours Emergent or Urgent Breast Ultrasonography in Patients with Clinically Suspected Breast Abscesses

    OpenAIRE

    Tanya W. Moseley; Ashley Stanley; Wei Wei; Jay R. Parikh

    2018-01-01

    Newly diagnosed breast abscesses are generally treated as a medical emergency that may necessitate immediate interventional treatment. At our institution, there is no in-house after-hours coverage for breast ultrasonography. We could find no peer-reviewed studies on the cost-effectiveness or clinical management impact of on-call ultrasound technologist coverage for imaging of breast abscesses. The purposes of this study were to determine the incidence of breast abscess in patients with clinic...

  3. Breast Cancer Screening (PDQ®)—Health Professional Version

    Science.gov (United States)

    Breast cancer screening most often includes mammography but can also include ultrasound, MRI, and other tests. Get detailed information about the potential benefits and harms of the tests used to screen for breast cancer in this summary for clinicians.

  4. Imaging screening of breast cancer: primary results in 5307 cases

    International Nuclear Information System (INIS)

    Xiao Qin; Zheng Xiaojing; Wang Xiaohong; Liu Quan; Jiang Chaoxia; Xu Linghui; Peng Weijun; Hu Danting; Wang Yufang; Gu Yajia; Liu Guangyu; Shao Zhimin; Shen Kunwei; Chang Cai; Han Chao

    2008-01-01

    Objective: To discuss the values of three screening methods for the detection of early breast cancer, and to analyze the features of the screening cancer. Methods: The first screening of breast cancer were performed in 5307 women who aged from 20 to 76 years with median age of 49 years. The three screening methods included physical examination with ultrasound and mammography, physical examination with mammography and mammography only. The rate of recall, biopsy, cancer detection of three methods were analyzed and the mammographic findings were reviewed. Chi-square test or Fisher's exact test were used for the statistics. Results: The recall rates were 4.90% (49/1001), 6.90% (166/2407) and 4. 48% (85/1899) in three methods respectively, the biopsy rates were 1.60% (16/1001), 1.04% (25/2407) and 0.63% (12/1899), the cancer detection rates were 0.50% (5/1001), 0.17% (4/2407) and 0 (0/1899). There were statistical differences among the three groups (χ 2 =12.99,6.264,8.764, P<0.05). Physical examination with ultrasound and mammography had the highest cancer detection rate, ten breast cancers were detected and 8 were early stage breast cancer. Of seven cancers detected by mammography, only two were found by ultrasound. A cluster of calcifications were found in 2 cases, linear calcifications in 2 cases. One case presented as a asymmetric density, one as a asymmetric density with calcifications, one as multiple nodules with a cluster of calcifications. Two breast cancers presented as asymmetric density were missed on mammography and diagnosed correctly after retrospective review. Conclusion: Physical examination with ultrasound and mammography is the best method for breast cancer screening. The breast cancer can be detected by mammography earlier than other methods. (authors)

  5. Breast cancer screening for severely disabled patients. Present status and future problems

    International Nuclear Information System (INIS)

    Matsuo, Kaneyuki

    2007-01-01

    Recently, the attendance rate for breast screening has been increasing in Japan. However, little is known about how to conduct effective breast cancer screening, especially for patients with mental disability. The purpose of this study was to clarify the present status of breast cancer screening for severely disabled patients. Breast screening was performed for 160 disabled patients by physical examination and ultrasound from 2002 to 2005. The patients included 158 women and two men, with an average age of 59 years old. Ten disabled patients (10/160; 6.3%) showed abnormal findings on physical examination and four (4/160; 2.5%) showed probably benign findings by ultrasound examination. Mammography (MMG) screening was performed for only 33 patients (33/160; 21%), one of whom needed further examination. One lesion was diagnosed as breast cancer (1/160; 0.63%). Breast ultrasound is useful for severely disabled patients because it is painless, easy and rapid to perform. On the other hand, it is sometimes difficult for such patients to participate in MMG screening because of their inability to adapt to the examination. Therefore, some psychological method, for example operant conditioning, will be necessary for breast screening of patients with severe mental disability. (author)

  6. Examining the sensitivity of ultrasound-guided large core biopsy for invasive breast carcinoma in a population screening programme

    International Nuclear Information System (INIS)

    Rouse, Hannah C.; Ussher, Simon; Cawson, Jennifer N.; Kavanagh, Anne M.

    2013-01-01

    To evaluate the sensitivity of ultrasound-guided core-needle biopsy (UCB) in invasive breast carcinoma and to establish causes of false-negative biopsy in a population screening programme. We identified 571 consecutive women diagnosed with surgically proven invasive breast cancer. Histology from 14-gauge UCB was compared with surgical histology to identify true-positive and false-negative ultrasound core biopsies. True-positive and false-negative groups were compared for tumour size and histology. On blinded review of UCB images and pathology reports from false negative (n=20) and a random sample of true-positive cases (n=80), we compared core sample number and needle visualisation in the lesion. Of 571 carcinomas sampled with UCB, 551 (96.5%) were true positive and 20 (3.5%) were false negative. The mean core number was 2.0 (range 1–3) for false negatives and 2.25 (range 1–4) for true positives (P=0.27). Mean tumour sizes were 13.3 and 16.2mm for the false-negative and true-positive groups, respectively (P=0.25). Tubular carcinomas represented 30% (6/20) of false-negative cases compared with 5.1% (28/551) of the true-positive cases (P<0.001). On blinded review, needle visualisation within the lesion was demonstrated in 47.4% (9/19) of false-negative cases and 76.3% (61/80) of true-positive cases (P=0.02).We demonstrated a sensitivity of 96.5% with a mean of 2.21 cores. False-negative results were more likely in the absence of post-fire needle position verification and with tubular carcinomas. Neither tumour size nor core number predicted diagnostic accuracy.

  7. Computer-assisted assessment of ultrasound real-time elastography: initial experience in 145 breast lesions.

    Science.gov (United States)

    Zhang, Xue; Xiao, Yang; Zeng, Jie; Qiu, Weibao; Qian, Ming; Wang, Congzhi; Zheng, Rongqin; Zheng, Hairong

    2014-01-01

    To develop and evaluate a computer-assisted method of quantifying five-point elasticity scoring system based on ultrasound real-time elastography (RTE), for classifying benign and malignant breast lesions, with pathologic results as the reference standard. Conventional ultrasonography (US) and RTE images of 145 breast lesions (67 malignant, 78 benign) were performed in this study. Each lesion was automatically contoured on the B-mode image by the level set method and mapped on the RTE image. The relative elasticity value of each pixel was reconstructed and classified into hard or soft by the fuzzy c-means clustering method. According to the hardness degree inside lesion and its surrounding tissue, the elasticity score of the RTE image was computed in an automatic way. Visual assessments of the radiologists were used for comparing the diagnostic performance. Histopathologic examination was used as the reference standard. The Student's t test and receiver operating characteristic (ROC) curve analysis were performed for statistical analysis. Considering score 4 or higher as test positive for malignancy, the diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 93.8% (136/145), 92.5% (62/67), 94.9% (74/78), 93.9% (62/66), and 93.7% (74/79) for the computer-assisted scheme, and 89.7% (130/145), 85.1% (57/67), 93.6% (73/78), 92.0% (57/62), and 88.0% (73/83) for manual assessment. Area under ROC curve (Az value) for the proposed method was higher than the Az value for visual assessment (0.96 vs. 0.93). Computer-assisted quantification of classical five-point scoring system can significantly eliminate the interobserver variability and thereby improve the diagnostic confidence of classifying the breast lesions to avoid unnecessary biopsy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  8. Computer-assisted assessment of ultrasound real-time elastography: Initial experience in 145 breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xue; Xiao, Yang [Shenzhen Key Lab for Molecular Imaging, Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China); Zeng, Jie [Department of Medical Ultrasonics, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou (China); Qiu, Weibao; Qian, Ming; Wang, Congzhi [Shenzhen Key Lab for Molecular Imaging, Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China); Zheng, Rongqin, E-mail: zhengronggin@hotmail.com [Department of Medical Ultrasonics, Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou (China); Zheng, Hairong, E-mail: hr.zheng@siat.ac.cn [Shenzhen Key Lab for Molecular Imaging, Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen (China)

    2014-01-15

    Purpose: To develop and evaluate a computer-assisted method of quantifying five-point elasticity scoring system based on ultrasound real-time elastography (RTE), for classifying benign and malignant breast lesions, with pathologic results as the reference standard. Materials and methods: Conventional ultrasonography (US) and RTE images of 145 breast lesions (67 malignant, 78 benign) were performed in this study. Each lesion was automatically contoured on the B-mode image by the level set method and mapped on the RTE image. The relative elasticity value of each pixel was reconstructed and classified into hard or soft by the fuzzy c-means clustering method. According to the hardness degree inside lesion and its surrounding tissue, the elasticity score of the RTE image was computed in an automatic way. Visual assessments of the radiologists were used for comparing the diagnostic performance. Histopathologic examination was used as the reference standard. The Student's t test and receiver operating characteristic (ROC) curve analysis were performed for statistical analysis. Results: Considering score 4 or higher as test positive for malignancy, the diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 93.8% (136/145), 92.5% (62/67), 94.9% (74/78), 93.9% (62/66), and 93.7% (74/79) for the computer-assisted scheme, and 89.7% (130/145), 85.1% (57/67), 93.6% (73/78), 92.0% (57/62), and 88.0% (73/83) for manual assessment. Area under ROC curve (A{sub z} value) for the proposed method was higher than the A{sub z} value for visual assessment (0.96 vs. 0.93). Conclusion: Computer-assisted quantification of classical five-point scoring system can significantly eliminate the interobserver variability and thereby improve the diagnostic confidence of classifying the breast lesions to avoid unnecessary biopsy.

  9. Myoepithelial carcinoma of the male breast: a rare case report

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    Myoepithelial carcinoma in a male breast with clinical features mimicking locally advanced breast ... palpable axillary lymphadenopathy. Ultrasound examination revealed a round hypoechoic solid mass just below the nipple-areola complex of.

  10. Incremental clinical value of ultrasound in men with mammographically confirmed gynecomastia.

    Science.gov (United States)

    Chen, Po-Hao; Slanetz, Priscilla J

    2014-01-01

    To determine whether ultrasound is of any value in male patients presenting with focal symptoms who have classic features of gynecomastia but no concerning findings on mammography. Over a 3-year period, all male patients who underwent mammographic evaluation were identified in this retrospective study. Patients with a mammographic diagnosis of gynecomastia and subsequent breast ultrasound at a large tertiary academic medical center comprised the study cohort. Men whose ultrasound diagnosis differed from the initial mammographic evaluation were analyzed for both additional benign findings as well as findings that warranted biopsy. A total of 353 mammograms were obtained from 327 unique patients (ages 18-95, mean 51 years). Of all mammographic examinations, gynecomastia was the sole finding in 73% (259). In those 259 studies, 85% were further evaluated with ultrasound, in which 6 (2.7%) showed additional benign findings, and 4 (1.8%) showed suspicious findings for which biopsy was recommended. No malignancies were detected in those patients. Furthermore, no malignancies were detected in patients whose mammogram revealed only normal fatty parenchyma or only gynecomastia. In all cases of cancer, mammography revealed visible masses. Judicious use of breast ultrasound in men improves outcome. Our data suggest that targeted ultrasound is of limited value in symptomatic male patients where mammography is negative or reveals only gynecomastia and leads to unnecessary benign biopsies in these patients. When mammography reveals concerning findings, ultrasound adds positively to clinical management. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  11. Incremental clinical value of ultrasound in men with mammographically confirmed gynecomastia

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Po-Hao, E-mail: howard_chen@post.harvard.edu [Harvard Medical School, 25 Shattuck Street, Boston, MA 02115 (United States); Department of Radiology, Hospital of University of Pennsylvania, 3400 Spruce Street, Philadlephia, PA 19104 (United States); Slanetz, Priscilla J., E-mail: pslanetz@bidmc.harvard.edu [Harvard Medical School, 25 Shattuck Street, Boston, MA 02115 (United States); Beth Israel Deaconess Medical Center, Department of Radiology, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2014-01-15

    Purpose: To determine whether ultrasound is of any value in male patients presenting with focal symptoms who have classic features of gynecomastia but no concerning findings on mammography. Materials and Methods: Over a 3-year period, all male patients who underwent mammographic evaluation were identified in this retrospective study. Patients with a mammographic diagnosis of gynecomastia and subsequent breast ultrasound at a large tertiary academic medical center comprised the study cohort. Men whose ultrasound diagnosis differed from the initial mammographic evaluation were analyzed for both additional benign findings as well as findings that warranted biopsy. Results: A total of 353 mammograms were obtained from 327 unique patients (ages 18–95, mean 51 years). Of all mammographic examinations, gynecomastia was the sole finding in 73% (259). In those 259 studies, 85% were further evaluated with ultrasound, in which 6 (2.7%) showed additional benign findings, and 4 (1.8%) showed suspicious findings for which biopsy was recommended. No malignancies were detected in those patients. Furthermore, no malignancies were detected in patients whose mammogram revealed only normal fatty parenchyma or only gynecomastia. In all cases of cancer, mammography revealed visible masses. Conclusion: Judicious use of breast ultrasound in men improves outcome. Our data suggest that targeted ultrasound is of limited value in symptomatic male patients where mammography is negative or reveals only gynecomastia and leads to unnecessary benign biopsies in these patients. When mammography reveals concerning findings, ultrasound adds positively to clinical management.

  12. Ultrasound, x-ray mammography, and histopathology of cystosarcoma phylloides

    Energy Technology Data Exchange (ETDEWEB)

    Cole-Beuglet, C. (Thomas Jefferson Univ. Hospital, Philadelphia, PA); Soriano, R.; Kurtz, A.B.; Meyer, J.E.; Kopans, D.B.; Goldberg, B.B.

    1983-02-01

    Ultrasound and x-ray mammograms were obtained in 8 patients with palpable breast masses, which were subsequently proven to be cystosarcoma phylloides. Histopathologic examination of the 8 tumors showed benign cystosarcoma phylloides in 5, recurrent benign tumor in 1, coexistent invasive papillary carcinoma in 1, and coexistent in situ duct cancer and in situ lobular cancer in 1. A retrospective review of the B-scan images was undertaken to list the descriptive ultrasound features of cystosarcoma phylloides. The ultrasound findings included low-level internal echoes, smooth walls, and good through transmission. The carcinomas were indistinguishable from the benign lesions, although ultrasound was able to distinguish the cystosarcoma phylloides lesions as predominantly solid lobulated masses.

  13. Automated Breast Ultrasonography (ABUS) in the Screening and Diagnostic Setting: Indications and Practical Use.

    Science.gov (United States)

    Rella, Rossella; Belli, Paolo; Giuliani, Michela; Bufi, Enida; Carlino, Giorgio; Rinaldi, Pierluigi; Manfredi, Riccardo

    2018-03-16

    Automated breast ultrasonography (ABUS) is a new imaging technology for automatic breast scanning through ultrasound. It was first developed to overcome the limitation of operator dependency and lack of standardization and reproducibility of handheld ultrasound. ABUS provides a three-dimensional representation of breast tissue and allows images reformatting in three planes, and the generated coronal plane has been suggested to improve diagnostic accuracy. This technique has been first used in the screening setting to improve breast cancer detection, especially in mammographically dense breasts. In recent years, numerous studies also evaluated its use in the diagnostic setting: they showed its suitability for breast cancer staging, evaluation of tumor response to neoadjuvant chemotherapy, and second-look ultrasound after magnetic resonance imaging. The purpose of this article is to provide a comprehensive review of the current body of literature about the clinical performance of ABUS, summarize available evidence, and identify gaps in knowledge for future research. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  14. Breast imaging using the Twente photoacoustic mammoscope (PAM): new clinical measurements

    Science.gov (United States)

    Heijblom, Michelle; Piras, Daniele; Ten Tije, Ellen; Xia, Wenfeng; van Hespen, Johan; Klaase, Joost; van den Engh, Frank; van Leeuwen, Ton; Steenbergen, Wiendelt; Manohar, Srirang

    2011-07-01

    Worldwide, yearly about 450,000 women die from the consequences of breast cancer. Current imaging modalities are not optimal in discriminating benign from malignant tissue. Visualizing the malignancy-associated increased hemoglobin concentration might significantly improve early diagnosis of breast cancer. Since photoacoustic imaging can visualize hemoglobin in tissue with optical contrast and ultrasound-like resolution, it is potentially an ideal method for early breast cancer imaging. The Twente Photoacoustic Mammoscope (PAM) has been developed specifically for breast imaging. Recently, a large clinical study has been started in the Medisch Spectrum Twente in Oldenzaal using PAM. In PAM, the breast is slightly compressed between a window for laser light illumination and a flat array ultrasound detector. The measurements are performed using a Q-switched Nd:YAG laser, pulsed at 1064 nm and a 1 MHz unfocused ultrasound detector array. Three-dimensional data are reconstructed using a delay and sum reconstruction algorithm. Those reconstructed images are compared with conventional imaging and histopathology. In the first phase of the study 12 patients with a malignant lesion and 2 patients with a benign cyst have been measured. The results are used to guide developments in photoacoustic mammography in order to pave the way towards an optimal technique for early diagnosis of breast cancer.

  15. Classification of breast masses in ultrasound images using self-adaptive differential evolution extreme learning machine and rough set feature selection.

    Science.gov (United States)

    Prabusankarlal, Kadayanallur Mahadevan; Thirumoorthy, Palanisamy; Manavalan, Radhakrishnan

    2017-04-01

    A method using rough set feature selection and extreme learning machine (ELM) whose learning strategy and hidden node parameters are optimized by self-adaptive differential evolution (SaDE) algorithm for classification of breast masses is investigated. A pathologically proven database of 140 breast ultrasound images, including 80 benign and 60 malignant, is used for this study. A fast nonlocal means algorithm is applied for speckle noise removal, and multiresolution analysis of undecimated discrete wavelet transform is used for accurate segmentation of breast lesions. A total of 34 features, including 29 textural and five morphological, are applied to a [Formula: see text]-fold cross-validation scheme, in which more relevant features are selected by quick-reduct algorithm, and the breast masses are discriminated into benign or malignant using SaDE-ELM classifier. The diagnosis accuracy of the system is assessed using parameters, such as accuracy (Ac), sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), Matthew's correlation coefficient (MCC), and area ([Formula: see text]) under receiver operating characteristics curve. The performance of the proposed system is also compared with other classifiers, such as support vector machine and ELM. The results indicated that the proposed SaDE algorithm has superior performance with [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], [Formula: see text], and [Formula: see text] compared to other classifiers.

  16. The Use of Complementary and Alternative Medicine Supplements of Potential Concern during Breast Cancer Chemotherapy

    Directory of Open Access Journals (Sweden)

    Erin Sweet

    2016-01-01

    Full Text Available Objective. While many Complementary and Alternative Medicines (CAM are unlikely to interact negatively with conventional oncology treatment, some ingestible CAM substances have biological activities that may reduce the effectiveness of chemotherapy or radiation. This study surveyed women with breast cancer in order to document the extent to which women with breast cancer use these CAM substances of concern concurrently with conventional treatments. Methods. A total of 398 women completed a survey describing their use of CAM at various time points in their cancer treatment. This report focuses on a subsample of 250 women receiving chemotherapy or radiation who reported using specific one or more of several chemotherapies. Results. Of those participating, 104 (43.7% of those receiving chemotherapy (n=238 and 45 (32.3% of those receiving radiation (139; 58.4% of all patients reported using one or more CAM substances that could be cause for concern when taken concurrently. Conclusion. Research is needed to understand the real risks associated with CAM and conventional polypharmacy. If risks associated with CAM conventional polypharmacy use prove to be substantial then improved systems to assure all women get advice regarding herb and supplement use during breast cancer treatment appear to be needed.

  17. [Lactational breast abscesses: Do we still need surgery?].

    Science.gov (United States)

    Debord, M-P; Poirier, E; Delgado, H; Charlot, M; Colin, C; Raudrant, D; Golfier, F; Dupuis, O

    2016-03-01

    To show the effectiveness of ultrasound-guided puncture in the treatment of lactational breast abscess and identify its risk factors. Retrospective descriptive study at the CHU of Lyon-Sud from December 2007 to December 2013, including patients with lactational breast abscess confirmed on ultrasound and treated with antibiotics and analgesics. Realisation of ultrasound-guided needle under local anesthesia by the radiologist and washing the cavity with physiological serum. Forty patients had lactational abscesses at an average of 10 weeks post-partum. Thirty-four patients were treated by needle aspiration, of which 2 had first surgical drainage. The average size of the abscess was 41.2mm. The success rate of needle aspiration was 91.2%. No cases of recurrence were observed, however, there were 5 fistulisations. In all, 91.2% were treated on an outpatient basis. In 87.8% of cases, breastfeeding was continued on the healthy side and in 48.5% of cases on the affected side. The major risk factor for abscess was mastitis in 91.1% of cases. Ultrasound guidance of needle aspiration should be gold standard for the treatment of lactational breast abscesses to continue breastfeeding including the affected side. Copyright © 2015. Published by Elsevier Masson SAS.

  18. A Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results.

    Science.gov (United States)

    Schulz-Wendtland, Rüdiger; Jud, Sebastian M; Fasching, Peter A; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W; Emons, Julius

    2017-06-01

    The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound - the second important imaging modality in complementary breast diagnostics - without increasing examination time or requiring additional staff.

  19. Ultrasound of the coracoclavicular ligaments in the acute phase of an acromioclavicular disjonction: Comparison of radiographic, ultrasound and MRI findings.

    Science.gov (United States)

    Faruch Bilfeld, Marie; Lapègue, Franck; Chiavassa Gandois, Hélène; Bayol, Marie Aurélie; Bonnevialle, Nicolas; Sans, Nicolas

    2017-02-01

    Acromioclavicular joint injuries are typically diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. The purpose of this study was to describe how the ultrasound findings of acromioclavicular joint injury compare with radiography and MRI findings. Forty-seven patients with suspected unilateral acromioclavicular joint injury after acute trauma were enrolled in this prospective study. All patients underwent digital radiography, ultrasound and 3T MRI. A modified Rockwood classification was used to evaluate the coracoclavicular ligaments. The classifications of acromioclavicular joint injuries diagnosed with radiography, ultrasound and MRI were compared. MRI was used as the gold standard. The agreement between the ultrasound and MRI findings was very good, with a correlation coefficient of 0.83 (95 % CI: 0.72-0.90; p acromioclavicular injury. • Ultrasound is appropriate for acute acromioclavicular trauma due to its accessibility. • Ultrasound contributes to the diagnostic work-up of acute lesions of the coracoclavicular ligaments. • Ultrasound is appropriate in patients likely to benefit from surgical treatment. • Ultrasound could be a supplement to standard radiography in acute acromioclavicular trauma.

  20. Primary Systemic Amyloidosis Presenting as Swollen Dense Breast: A Case Report

    International Nuclear Information System (INIS)

    Lee, Byung Hoon; Kim, Mi Young; Kim, Su Young; Hwang, Yoon Joon; Han, Yoon Hee; Seo, Jung Wook; Kim, Yong Hoon; Cha, Soon Joo; Hur, Gham; Joo, Mee

    2006-01-01

    Breast involvement of primary systemic amyloidosis is rare. This is a rare case of breast amyloidosis presenting as a diffuse infiltrative lesion. We present the mammographic, ultrasound, and MR findings of a systemic primary amyloidosis involving the breast with diffuse infiltrative pattern

  1. Application of a topical vapocoolant spray decreases pain at the site of initial intradermal anaesthetic injection during ultrasound-guided breast needle biopsy

    International Nuclear Information System (INIS)

    Collado-Mesa, F.; Net, J.M.; Arheart, K.; Klevos, G.A.; Yepes, M.M.

    2015-01-01

    Aim: To assess whether the application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy decreases pain at the site of the initial injection. Materials and methods: In this institutional review board-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant study, 50 women aged 49.1 ± 1.6 years (mean ± standard error) were recruited and provided written informed consent. Participants served as their own controls and were blinded as to whether a topical vapocoolant spray or a placebo was used immediately prior to the initial local anaesthetic injection at two separate biopsy sites. With the exception of the application of vapocoolant or placebo, the entire ultrasound-guided procedure was performed according to a routine protocol. Participants recorded pain at initial injection site on a visual analogue scale. General linear mixed models for repeated measures analysis of variance and a 0.05 significance level were used. Results: Application of topical vapocoolant spray was shown to significantly decrease pain at the site of initial intradermal anaesthetic injection as compared to placebo (p<0.001). Treatment effect was independent of age of the subject, race/ethnicity, operator, type of biopsy device, and histopathology result. No complications from vapocoolant spray use were reported. Conclusion: Application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy significantly decreases pain at the site of the initial injection and could contribute to improve the patient's overall procedural experience. -- Highlights: •Topical vapocoolant spray decreased pain at site of initial anesthetic injection (

  2. Comparisons of Positron Emission Tomography/Computed Tomography and Ultrasound Imaging for Detection of Internal Mammary Lymph Node Metastases in Patients With Breast Cancer and Pathologic Correlation by Ultrasound-Guided Biopsy Procedures.

    Science.gov (United States)

    An, Yeong Yi; Kim, Sung Hun; Kang, Bong Joo; Lee, Ah Won

    2015-08-01

    To compare the diagnostic performance of [(18)F]fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) and ultrasound imaging (US) with pathologic results obtained by US-guided biopsy and to evaluate the role of US in detecting internal mammary lymph node (LN) metastases in patients with breast cancer. Between January 2008 and December 2012, 37 patients with breast cancer (median age, 51.4 years; range, 40-79 years) underwent US-guided biopsy for suspected internal mammary LN metastases. Medical records, radiologic images, and reports were reviewed and correlated with pathologic results. The positive internal mammary LN metastasis rate was 78.4%. All biopsies were performed safely without major complications. Only 8.1% of obtained samples were unsatisfactory. There were statistically significant differences in lesion size (P = .0002), standardized uptake value on PET/CT (P = .0015), biopsy methods (P = .002), and specimen adequacy (P = .007) between metastatic and benign groups. Of the clinical factorsreviewed, only concurrent distant metastasis was correlated with internal mammary LN metastasis (P< .0001). Sensitivities for detecting internal mammary LN metastases were 76.7%, 96.7%, and 92.9% for initial US examinations, initial US combined with second-look US for initially missed cases, and PET/CT, respectively (P= .017). In a subgroup analysis, the only significant difference found was in sensitivities between initial and combined US (P = .019). In a receiver operating characteristic curve analysis, the area under the curve for PET/CT using standardized uptake criteria (0.87) was higher than that for US using size criteria (0.83); however, this difference was not significant. Although PET/CT is the best noninvasive method for evaluating internal mammary LN metastases, US is also useful if internal mammary LN evaluation is routine during standard US surveillance of patients with breast cancer. Additionally, US-guided biopsies could be

  3. A Retrospective Study Evaluating the Impact of Preoperative Breast MRI on Surgical Decision-Making in Young Patients (≤50 Years with Invasive Breast Cancer

    Directory of Open Access Journals (Sweden)

    Som D. Mukherjee

    2016-01-01

    Full Text Available Introduction Breast magnetic resonance imaging (MRI is considered a more sensitive diagnostic test for detecting invasive breast cancer than mammography or breast ultrasound. Breast MRI may be particularly useful in younger premenopausal women with higher density breast tissue for differentiating between dense fibroglandular breast tissue and breast malignancies. The main objective of this study was to determine the impact of preoperative breast MRI on surgical decision-making in young women with breast cancer. Methods A retrospective review of patients with newly diagnosed invasive breast cancer and age of ≤50 years was performed. All patients underwent physical examination, preoperative mammogram, breast ultrasound, and bilateral breast MRI. Two breast cancer surgeons reviewed the preoperative mammogram report, breast ultrasound report, and physical examination summary and were asked if they would recommend a lumpectomy, a quandrantectomy, or a mastectomy. A few weeks later, the two surgeons were shown the same information with the breast MRI report and were asked what type of surgery they would now recommend. In each case, MRI was classified by two adjudicators as having affected the surgical outcome in a positive, negative, or neutral fashion. A positive impact was defined as the situation where breast MRI detected additional disease that was not found on physical examination, mammogram, or breast ultrasound and led to an appropriate change in surgical management. A negative impact was defined as the situation where breast MRI led the surgeon to recommend more extensive surgery, with less extensive disease actually found at pathology. No impact was defined as the situation where MRI findings did not alter surgical recommendations or outcomes. Results Of 37 patients whose charts were reviewed, five patients were deemed to be ineligible due to having received neoadjuvant chemotherapy, having previous breast implants, or having had their

  4. Development of three-dimensional radiotherapy techniques in breast cancer

    Science.gov (United States)

    Coles, Charlotte E.

    Radiotherapy following conservation surgery decreases local relapse and death from breast cancer. Currently, the challenge is to minimise the morbidity caused by this treatment without losing efficacy. Despite many advances in radiation techniques in other sites of the body, the majority of breast cancer patients are still planned and treated using 2-dimensional simple radiotherapy techniques. In addition, breast irradiation currently consumes 30% of the UK's radiotherapy workload. Therefore, any change to more complex treatment should be of proven benefit. The primary objective of this research is to develop and evaluate novel radiotherapy techniques to decrease irradiation of normal structures and improve localisation of the tumour bed. I have developed a forward-planned intensity modulated (IMRT) breast radiotherapy technique, which has shown improved dosimetry results compared to standard breast radiotherapy. Subsequently, I have developed and implemented a phase III randomised controlled breast IMRT trial. This National Cancer Research Network adopted trial will answer an important question regarding the clinical benefit of breast IMRT. It will provide DNA samples linked with high quality clinical outcome data, for a national translational radiogenomics study investigating variation in normal tissue toxicity. Thus, patients with significant late normal tissue side effects despite good dose homogeneity will provide the best model for finding differences due to underlying genetics. I evaluated a novel technique using high definition free-hand 3-dimensional (3D) ultrasound in a phantom study, and the results suggested that this is an accurate and reproducible method for tumour bed localisation. I then compared recognised methods of tumour bed localisation with the 3D ultrasound method in a clinical study. The 3D ultrasound technique appeared to accurately represent the shape and spatial position of the tumour cavity. This tumour bed localisation research

  5. Relationship between breast sound speed and mammographic percent density

    Science.gov (United States)

    Sak, Mark; Duric, Nebojsa; Boyd, Norman; Littrup, Peter; Myc, Lukasz; Faiz, Muhammad; Li, Cuiping; Bey-Knight, Lisa

    2011-03-01

    Despite some shortcomings, mammography is currently the standard of care for breast cancer screening and diagnosis. However, breast ultrasound tomography is a rapidly developing imaging modality that has the potential to overcome the drawbacks of mammography. It is known that women with high breast densities have a greater risk of developing breast cancer. Measuring breast density is accomplished through the use of mammographic percent density, defined as the ratio of fibroglandular to total breast area. Using an ultrasound tomography (UST) prototype, we created sound speed images of the patient's breast, motivated by the fact that sound speed in a tissue is proportional to the density of the tissue. The purpose of this work is to compare the acoustic performance of the UST system with the measurement of mammographic percent density. A cohort of 251 patients was studied using both imaging modalities and the results suggest that the volume averaged breast sound speed is significantly related to mammographic percent density. The Spearman correlation coefficient was found to be 0.73 for the 175 film mammograms and 0.69 for the 76 digital mammograms obtained. Since sound speed measurements do not require ionizing radiation or physical compression, they have the potential to form the basis of a safe, more accurate surrogate marker of breast density.

  6. Efficacy of reovirus against breast cancer

    International Nuclear Information System (INIS)

    Zhu Jingzhi; Chen Jue; Dong Shengxiang; Yan Weili; Wu Zhiyong

    2011-01-01

    To investigate the role of oncolytic reovirus in breast cancer, a tumor xenograft model of NOD/SCID mice was established using a biopsy sample of a primary infiltrating ductal carcinoma obtained from a breast cancer patient. The result of HE and TUNEL was analyzed after injecting the reovirus peritoneally for 3 days. The results showed that estrogen supplementation was required to establish appropriate human breast cancer xenograft model of NOD/SCID mice. 29.6% of these transplanted tumors grew with supplementation of Estrogen. Otherwise none grew (P<0.01). ER of the xenograft model was positive.After treatment with reovirus for 3 days, breast cancer cells were disrupted and disappeared which induced tissue looseness. The rate of apoptosis increased double than before. The biological characteristics of tumor xenograft model confirm with the primary breast cancer. The oncolytic reovirus can kill breast cancer in short time. (authors)

  7. An effective approach of lesion segmentation within the breast ultrasound image based on the cellular automata principle.

    Science.gov (United States)

    Liu, Yan; Cheng, H D; Huang, Jianhua; Zhang, Yingtao; Tang, Xianglong

    2012-10-01

    In this paper, a novel lesion segmentation within breast ultrasound (BUS) image based on the cellular automata principle is proposed. Its energy transition function is formulated based on global image information difference and local image information difference using different energy transfer strategies. First, an energy decrease strategy is used for modeling the spatial relation information of pixels. For modeling global image information difference, a seed information comparison function is developed using an energy preserve strategy. Then, a texture information comparison function is proposed for considering local image difference in different regions, which is helpful for handling blurry boundaries. Moreover, two neighborhood systems (von Neumann and Moore neighborhood systems) are integrated as the evolution environment, and a similarity-based criterion is used for suppressing noise and reducing computation complexity. The proposed method was applied to 205 clinical BUS images for studying its characteristic and functionality, and several overlapping area error metrics and statistical evaluation methods are utilized for evaluating its performance. The experimental results demonstrate that the proposed method can handle BUS images with blurry boundaries and low contrast well and can segment breast lesions accurately and effectively.

  8. Breast metastasis from cutaneous malignant melanoma mimicking a breast cancer.

    Science.gov (United States)

    Maniglio, Marina; Capalbo, Emanuela; Viganò, Sara; Trecate, Giovanna; Scaperrotta, Gianfranco Paride; Panizza, Pietro

    2015-06-25

    Breast metastases are very uncommon, either from solid tumors or malignant melanoma. We present the case of a 42-year-old woman with a history of cutaneous melanoma of the shoulder excised 21 years ago. She presented with a palpable lump in the upper outer quadrant of the right breast. Ultrasound demonstrated a solid mass within a cystic lesion. A core biopsy was taken and first histology reported a poorly differentiated primary breast cancer suspected to be triple negative. MRI detected a satellite lesion in the same breast, a focus of suspected enhancement in the other breast, and the extramammary finding of an enhancing pulmonary lesion. Staging computed tomography detected widespread metastases to the lungs, brain, subcutaneous left shoulder, liver, pancreas, and hepatorenal recess. A core biopsy was taken from the left breast lesion and the previous slides were reviewed; histopathology and immunohistochemistry were in keeping with metastasis from melanoma. The possibility of a metastatic lesion to the breast should be taken into account in any patient presenting with a breast lump and a previous history of melanoma. Breast involvement cannot be considered an isolated finding, as it might be the first manifestation of widespread disease.

  9. BI-RADS categorisation of 2708 consecutive nonpalpable breast lesions in patients referred to a dedicated breast care unit

    International Nuclear Information System (INIS)

    Hamy, A.S.; Giacchetti, S.; Cuvier, C.; Perret, F.; Bonfils, S.; Charveriat, P.; Hocini, H.; Espie, M.; Albiter, M.; Bazelaire, C. de; Roquancourt, A. de

    2012-01-01

    To determine the malignancy rate of nonpalpable breast lesions, categorised according to the Breast Imaging Reporting and Data System (BI-RADS) classification in the setting of a Breast Care Unit. All nonpalpable breast lesions from consecutive patients referred to a dedicated Breast Care Unit were prospectively reviewed and classified into 5 BI-RADS assessment categories (0, 2, 3, 4, and 5). A total of 2708 lesions were diagnosed by mammography (71.6%), ultrasound (8.7%), mammography and ultrasound (19.5%), or MRI (0.2%). The distribution of the lesions by BI-RADS category was: 152 in category 0 (5.6%), 56 in category 2 (2.1%), 742 in category 3 (27.4%), 1523 in category 4 (56.2%) and 235 in category 5 (8.7%). Histology revealed 570 malignant lesions (32.9%), 152 high-risk lesions (8.8%), and 1010 benign lesions (58.3%). Malignancy was detected in 17 (2.3%) category 3 lesions, 364 (23.9%) category 4 lesions and 185 (78.7%) category 5 lesions. Median follow-up was 36.9 months. This pragmatic study reflects the assessment and management of breast impalpable abnormalities referred for care to a specialized Breast Unit. Multidisciplinary evaluation with BI-RADS classification accurately predicts malignancy, and reflects the quality of management. This assessment should be encouraged in community practice appraisal. (orig.)

  10. Ultrasound description of Pecs II (modified Pecs I): a novel approach to breast surgery.

    Science.gov (United States)

    Blanco, R; Fajardo, M; Parras Maldonado, T

    2012-11-01

    The Pecs block (pectoral nerves block) is an easy and reliable superficial block inspired by the infraclavicular block approach and the transversus abdominis plane blocks. Once the pectoralis muscles are located under the clavicle the space between the two muscles is dissected to reach the lateral pectoral and the medial pectoral nerves. The main indications are breast expanders and subpectoral prosthesis where the distension of these muscles is extremely painful. A second version of the Pecs block is described, called "modified Pecs block" or Pecs block type II. This novel approach aims to block at least the pectoral nerves, the intercostobrachial, intercostals III-IV-V-VI and the long thoracic nerve. These nerves need to be blocked to provide complete analgesia during breast surgery, and it is an alternative or a rescue block if paravertebral blocks and thoracic epidurals failed. This block has been used in our unit in the past year for the Pecs I indications described, and in addition for, tumorectomies, wide excisions, and axillary clearances. The ultrasound sequence to perform this block is shown, together with simple X-ray dye images and gadolinium MRI images to understand the spread and pathways that can explain the benefit of this novel approach. Copyright © 2012 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  11. Semi-automatic breast ultrasound image segmentation based on mean shift and graph cuts.

    Science.gov (United States)

    Zhou, Zhuhuang; Wu, Weiwei; Wu, Shuicai; Tsui, Po-Hsiang; Lin, Chung-Chih; Zhang, Ling; Wang, Tianfu

    2014-10-01

    Computerized tumor segmentation on breast ultrasound (BUS) images remains a challenging task. In this paper, we proposed a new method for semi-automatic tumor segmentation on BUS images using Gaussian filtering, histogram equalization, mean shift, and graph cuts. The only interaction required was to select two diagonal points to determine a region of interest (ROI) on an input image. The ROI image was shrunken by a factor of 2 using bicubic interpolation to reduce computation time. The shrunken image was smoothed by a Gaussian filter and then contrast-enhanced by histogram equalization. Next, the enhanced image was filtered by pyramid mean shift to improve homogeneity. The object and background seeds for graph cuts were automatically generated on the filtered image. Using these seeds, the filtered image was then segmented by graph cuts into a binary image containing the object and background. Finally, the binary image was expanded by a factor of 2 using bicubic interpolation, and the expanded image was processed by morphological opening and closing to refine the tumor contour. The method was implemented with OpenCV 2.4.3 and Visual Studio 2010 and tested for 38 BUS images with benign tumors and 31 BUS images with malignant tumors from different ultrasound scanners. Experimental results showed that our method had a true positive rate (TP) of 91.7%, a false positive (FP) rate of 11.9%, and a similarity (SI) rate of 85.6%. The mean run time on Intel Core 2.66 GHz CPU and 4 GB RAM was 0.49 ± 0.36 s. The experimental results indicate that the proposed method may be useful in BUS image segmentation. © The Author(s) 2014.

  12. Palpable discrete breast masses in young women: Two of the ...

    African Journals Online (AJOL)

    non-invasive or minimally invasive means of diagnosis helps to lessen the anxiety and aids in ... involves clinical breast examination (CBE), ultrasound scans and cytological ..... in Breast Cancer Screening and Diagnosis. 4th ed. Summary ...

  13. Mondor's Disease of the Breast in a Nigerian Woman Previously ...

    African Journals Online (AJOL)

    It is seldom diagnosed, and its etiology and epidemiology ... breast cancer have been postulated. ... breast specialists to include it as a diagnostic consideration in patients presenting .... had subsided, and the repeat ultrasound scan of her right.

  14. Primary breast tuberculosis. A case report

    International Nuclear Information System (INIS)

    Filippou, D.C.; Rizos, S.; Nissiotis, A.

    2003-01-01

    Background. The differential diagnosis of primary breast tuberculosis with other benign or malignant conditions can be difficult with the current imaging techniques that used to recognize breast pathologies. In many cases mammographic and ultrasound characteristics of breast tuberculosis are similar to those of breast cancer. Case report. We present a case of primary breast tuberculosis, with no previous history of the disease, which was diagnosed during the operation. Conclusions. Primary breast tuberculosis can be misdiagnosed. In these cases a tuberculosis infection history is negative, the mammographic and radiological findings obscure and the mass can be misdiagnosed as carcinoma. The diagnosis is achieved after the surgical removal of the mass and histological examination of the specimen. (author)

  15. Breast-specific gamma-imaging: molecular imaging of the breast using 99mTc-sestamibi and a small-field-of-view gamma-camera.

    Science.gov (United States)

    Jones, Elizabeth A; Phan, Trinh D; Blanchard, Deborah A; Miley, Abbe

    2009-12-01

    Breast-specific gamma-imaging (BSGI), also known as molecular breast imaging, is breast scintigraphy using a small-field-of-view gamma-camera and (99m)Tc-sestamibi. There are many different types of breast cancer, and many have characteristics making them challenging to detect by mammography and ultrasound. BSGI is a cost-effective, highly sensitive and specific technique that complements other imaging modalities currently being used to identify malignant lesions in the breast. Using the current Society of Nuclear Medicine guidelines for breast scintigraphy, Legacy Good Samaritan Hospital began conducting BSGI, breast scintigraphy with a breast-optimized gamma-camera. In our experience, optimal imaging has been conducted in the Breast Center by a nuclear medicine technologist. In addition, the breast radiologists read the BSGI images in correlation with the mammograms, ultrasounds, and other imaging studies performed. By modifying the current Society of Nuclear Medicine protocol to adapt it to the practice of breast scintigraphy with these new systems and by providing image interpretation in conjunction with the other breast imaging studies, our center has found BSGI to be a valuable adjunctive procedure in the diagnosis of breast cancer. The development of a small-field-of-view gamma-camera, designed to optimize breast imaging, has resulted in improved detection capabilities, particularly for lesions less than 1 cm. Our experience with this procedure has proven to aid in the clinical work-up of many of our breast patients. After reading this article, the reader should understand the history of breast scintigraphy, the pharmaceutical used, patient preparation and positioning, imaging protocol guidelines, clinical indications, and the role of breast scintigraphy in breast cancer diagnosis.

  16. MO-DE-210-06: Development of a Supercompounded 3D Volumetric Ultrasound Image Guidance System for Prone Accelerated Partial Breast Irradiation (APBI)

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, T; Hrycushko, B; Zhao, B; Jiang, S; Gu, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: For early-stage breast cancer, accelerated partial breast irradiation (APBI) is a cost-effective breast-conserving treatment. Irradiation in a prone position can mitigate respiratory induced breast movement and achieve maximal sparing of heart and lung tissues. However, accurate dose delivery is challenging due to breast deformation and lumpectomy cavity shrinkage. We propose a 3D volumetric ultrasound (US) image guidance system for accurate prone APBI Methods: The designed system, set beneath the prone breast board, consists of a water container, an US scanner, and a two-layer breast immobilization cup. The outer layer of the breast cup forms the inner wall of water container while the inner layer is attached to patient breast directly to immobilization. The US transducer scans is attached to the outer-layer of breast cup at the dent of water container. Rotational US scans in a transverse plane are achieved by simultaneously rotating water container and transducer, and multiple transverse scanning forms a 3D scan. A supercompounding-technique-based volumetric US reconstruction algorithm is developed for 3D image reconstruction. The performance of the designed system is evaluated with two custom-made gelatin phantoms containing several cylindrical inserts filled in with water (11% reflection coefficient between materials). One phantom is designed for positioning evaluation while the other is for scaling assessment. Results: In the positioning evaluation phantom, the central distances between the inserts are 15, 20, 30 and 40 mm. The distances on reconstructed images differ by −0.19, −0.65, −0.11 and −1.67 mm, respectively. In the scaling evaluation phantom, inserts are 12.7, 19.05, 25.40 and 31.75 mm in diameter. Measured inserts’ sizes on images differed by 0.23, 0.19, −0.1 and 0.22 mm, respectively. Conclusion: The phantom evaluation results show that the developed 3D volumetric US system can accurately localize target position and determine

  17. OPTIMIZATION OF DIAGNOSTIC IMAGING IN BREAST CANCER

    Directory of Open Access Journals (Sweden)

    S. A. Velichko

    2015-01-01

    Full Text Available The paper presents the results of breast imaging for 47200 women. Breast cancer was detected in 862 (1.9% patients, fibroadenoma in 1267 (2.7% patients and isolated breast cysts in 1162 (2.4% patients. Different types of fibrocystic breast disease (adenosis, diffuse fibrocystic changes, local fibrosis and others were observed in 60.1% of women. Problems of breast cancer visualization during mammography, characterized by the appearance of fibrocystic mastopathy (sclerosing adenosis, fibrous bands along the ducts have been analyzed. Data on the development of diagnostic algorithms including the modern techniques for ultrasound and interventional radiology aimed at detecting early breast cancer have been presented.  

  18. The role of cone-beam breast-CT for breast cancer detection relative to breast density

    Energy Technology Data Exchange (ETDEWEB)

    Wienbeck, Susanne; Uhlig, Johannes; Fintel, Eva von; Stahnke, Vera; Lotz, Joachim [University Medical Center Goettingen, Institute for Diagnostic and Interventional Radiology, Goettingen (Germany); Luftner-Nagel, Susanne; Fischer, Uwe [Diagnostic Breast Center Goettingen, Goettingen (Germany); Zapf, Antonia [University Medical Center Goettingen, Department of Medical Statistics, Goettingen (Germany); Surov, Alexey [University of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany)

    2017-12-15

    To evaluate the impact of breast density on the diagnostic accuracy of non-contrast cone-beam breast computed tomography (CBBCT) in comparison to mammography for the detection of breast masses. A retrospective study was conducted from August 2015 to July 2016. Fifty-nine patients (65 breasts, 112 lesions) with BI-RADS, 5th edition 4 or 5 assessment in mammography and/or ultrasound of the breast received an additional non-contrast CBBCT. Independent double blind reading by two radiologists was performed for mammography and CBBCT imaging. Sensitivity, specificity and AUC were compared between the modalities. Breast lesions were histologically examined in 85 of 112 lesions (76%). The overall sensitivity for CBBCT (reader 1: 91%, reader 2: 88%) was higher than in mammography (both: 68%, p<0.001), and also for the high-density group (p<0.05). The specificity and AUC was higher for mammography in comparison to CBBCT (p<0.05 and p<0.001). The interobserver agreement (ICC) between the readers was 90% (95% CI: 86-93%) for mammography and 87% (95% CI: 82-91%) for CBBCT. Compared with two-view mammography, non-contrast CBBCT has higher sensitivity, lower specificity, and lower AUC for breast mass detection in both high and low density breasts. (orig.)

  19. Large-scale propagation of ultrasound in a 3-D breast model based on high-resolution MRI data.

    Science.gov (United States)

    Salahura, Gheorghe; Tillett, Jason C; Metlay, Leon A; Waag, Robert C

    2010-06-01

    A 40 x 35 x 25-mm(3) specimen of human breast consisting mostly of fat and connective tissue was imaged using a 3-T magnetic resonance scanner. The resolutions in the image plane and in the orthogonal direction were 130 microm and 150 microm, respectively. Initial processing to prepare the data for segmentation consisted of contrast inversion, interpolation, and noise reduction. Noise reduction used a multilevel bidirectional median filter to preserve edges. The volume of data was segmented into regions of fat and connective tissue by using a combination of local and global thresholding. Local thresholding was performed to preserve fine detail, while global thresholding was performed to minimize the interclass variance between voxels classified as background and voxels classified as object. After smoothing the data to avoid aliasing artifacts, the segmented data volume was visualized using isosurfaces. The isosurfaces were enhanced using transparency, lighting, shading, reflectance, and animation. Computations of pulse propagation through the model illustrate its utility for the study of ultrasound aberration. The results show the feasibility of using the described combination of methods to demonstrate tissue morphology in a form that provides insight about the way ultrasound beams are aberrated in three dimensions by tissue.

  20. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: An analysis for Austria

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, R., E-mail: renate.gruber@meduniwien.ac.a [Medical University of Vienna, Department of Radiology, Division of Molecular and Gender Imaging, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Walter, E. [Institute of Pharmacoeconomic Research, Wolfengasse 4/7, A-1010 Vienna (Austria); Helbich, T.H. [Medical University of Vienna, Department of Radiology, Division of Molecular and Gender Imaging, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2010-06-15

    Purpose: To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. Materials and methods: In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Results: Overall cost savings for US-guided LCBB over OSB were Euro 977 ( Euro 2,337/ Euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were Euro 1,542 ( Euro 2,600/ Euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. Conclusion: From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be Euro 18.5 million.

  1. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: An analysis for Austria

    International Nuclear Information System (INIS)

    Gruber, R.; Walter, E.; Helbich, T.H.

    2010-01-01

    Purpose: To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. Materials and methods: In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Results: Overall cost savings for US-guided LCBB over OSB were Euro 977 ( Euro 2,337/ Euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were Euro 1,542 ( Euro 2,600/ Euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. Conclusion: From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be Euro 18.5 million.

  2. Classification and management of gynecomastia: defining the role of ultrasound-assisted liposuction.

    Science.gov (United States)

    Rohrich, Rod J; Ha, Richard Y; Kenkel, Jeffrey M; Adams, William P

    2003-02-01

    Gynecomastia, or excessive male breast development, has an incidence of 32 to 65 percent in the male population. This condition has important physical and psychological impacts. Advances in elucidating the pathophysiology of gynecomastia have been made, though understanding remains limited. Recommendations for evaluation and workup have varied and are often arbitrary. A diagnostic algorithm is suggested, with emphasis on a comprehensive history, physical examination, and minimizing unnecessary diagnostic testing. Medical management has had limited success; surgical therapy, primarily through excisional techniques, has been the accepted standard. Although effective, excisional techniques subject patients to large, visible scars. Ultrasound-assisted liposuction has recently emerged as a safe and effective method for the treatment of gynecomastia. It is particularly efficient in the removal of the dense, fibrous male breast tissue while offering advantages in minimal external scarring. A new system of classification and graduated treatment is proposed, based on glandular versus fibrous hypertrophy and degree of breast ptosis (skin excess). The authors' series of 61 patients with gynecomastia from 1987 to 2000 at the University of Texas Southwestern Department of Plastic Surgery demonstrated an overall success rate of 86.9 percent using suction-assisted lipectomy (1987 to 1997) and ultrasound-assisted liposuction (1997 to 2000). The authors have found ultrasound-assisted liposuction to be effective in treating most grades of gynecomastia. Excisional techniques are reserved for severe gynecomastia with significant skin excess after attempted ultrasound-assisted liposuction.

  3. Technical evaluation of Virtual Touch™ tissue quantification and elastography in benign and malignant breast tumors

    Science.gov (United States)

    JIANG, QUAN; ZHANG, YUAN; CHEN, JIAN; ZHANG, YUN-XIAO; HE, ZHU

    2014-01-01

    The aim of this study was to investigate the diagnostic value of the Virtual Touch™ tissue quantification (VTQ) and elastosonography technologies in benign and malignant breast tumors. Routine preoperative ultrasound, elastosonography and VTQ examinations were performed on 86 patients with breast lesions. The elastosonography score and VTQ speed grouping of each lesion were measured and compared with the pathological findings. The difference in the elastosonography score between the benign and malignant breast tumors was statistically significant (Pbenign and malignant tumors was also statistically significant (P<0.05). In addition, the diagnostic accuracy of conventional ultrasound, elastosonography, VTQ technology and the combined methods showed statistically significant differences (P<0.05). The use of the three technologies in combination significantly improved the diagnostic accuracy to 91.86%. In conclusion, the combination of conventional ultrasound, elastosonography and VTQ technology can significantly improve accuracy in the diagnosis of breast cancer. PMID:25187797

  4. Histologic work-up of non-palpable breast lesions classified as probably benign at initial mammography and/or ultrasound (BI-RADS category 3).

    Science.gov (United States)

    Gruber, R; Jaromi, S; Rudas, M; Pfarl, G; Riedl, C C; Flöry, D; Graf, O; Sickles, E A; Helbich, T H

    2013-03-01

    To determine the accuracy of a probably benign assessment of non-palpable breast lesions (BI-RADS category 3) at mammography and/or ultrasound with immediate histological work-up. Stereotactic or ultrasound guided core needle breast biopsy (NBB) was performed to evaluate 288 lesions, which were prospectively assessed as BI-RADS category 3. Imaging findings included 195 masses, 73 calcification cases, 16 focal asymmetries, and four architectural distortion cases. After NBB, patients underwent either open surgical biopsy (OSB) (n=204) or mammographic follow-up (n=84) for at least 24 months. Histological results of NBB were compared with those of OSB. Three of the 288 lesions (1.0%) proved to be malignant at histological work-up, two of them were ductal carcinoma in situ (DCIS) and one of them was an invasive carcinoma. NBB revealed invasive carcinoma in 1/288 (0.35%) and atypical ductal hyperplasia (ADH) in 13/288 (4.5%) lesions. OSB revealed DCIS in 2/204 (1%) and invasive carcinoma in 1/204 (0.5%) lesions. The two DCIS were underestimated as ADH by NBB. The remaining 285 (99%) lesions proved to be benign at OSB or remained stable during follow-up. Confirmed by tissue diagnosis, the low likelihood of malignancy of prospectively assessed probably benign lesions is below the 2% threshold established for BI-RADS category 3. Imaging follow-up is a safe and effective alternative to immediate histological work-up for such lesions. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Benign osseous metaplasia of the breast: Case report

    Directory of Open Access Journals (Sweden)

    Hassan Alyami

    Full Text Available Introduction: Benign Osseous metaplasia of the breast is rare, with only a few cases reported in the literature. Here we present a case of benign osseous metaplasia of the breast presenting as a breast lump. Case presentation: 38-year-old previously well woman presented with a one-year history of bilateral breast pain and a left-sided breast lump. Ultrasound and mammography suggested calcified fibroadenoma. An ultrasound-guided true cut biopsy revealed fibrous tissue containing foci of adenosis in the presence of a myoepithelial cell layer. Excision biopsy was performed, and histopathological examination showed bone matrix deposition occupying most of the nodule with peripheral hyalinized tissue but no evidence of malignancy. A diagnosis of benign osseous metaplasia of the breast was made, and the patient recovered well without recurrence after lump excision. Discussion: Only a few cases of osseous metaplasia are reported in the literature. Most reported cases are malignant, such as in fibrosarcoma, malignant mesenchymoma, osteoid sarcoma, osteogenic sarcoma, and osteochondrosarcoma.Very few cases of osseous sarcoma are reported in benign lesions such as fibroadenoma, pleomorphic adenoma, benign mesenchymoma, phyllodes tumor, and amyloid tumor of the breast. Joshi et al. first reported a case of benign osseous metaplasia of the breast presenting as breast lump in an HIV-positive patient [18]. We, therefore, consider this case to be the second case report of benign osseous metaplasia of the breast presenting as a breast lump, but the patient had no chronic illness. Conclusion: A breast lump can be the first presentation of benign osseous metaplasia. Keywords: Benign osseous metaplasia, Breast lump, Case report

  6. Ultrasound in evaluating ovarian reserve

    Directory of Open Access Journals (Sweden)

    Eman Ahmaed Shawky Sabek

    2015-12-01

    Full Text Available The objective of this study was to compare the diagnostic accuracy of transvaginal ultrasound (TVS, as a less invasive technique instead of hormonal assay to evaluate the ovarian reserve. This study included fifty-five females with breast cancer and we compared the ovarian reserve for these patients by hormonal assay through measuring the serum AntiMullerian Hormone (AMH level and follicular stimulating hormone (FSH level before and after chemotherapy, and by transvaginal ultrasound through the ovarian volume (OV calculation and counting the Antral follicles (AFC before and after chemotherapy treatment. There was decline in the AntiMullerian Hormone level after chemotherapy by 27 ± 11.19% and decrease in the Antral follicle counts by 21 ± 13.43%. In conclusion there was strong relation between AMH level and AFC which makes the use of transvaginal ultrasound is a reliable alternative method to the hormonal assay to detect the ovarian reserve.

  7. A Computer-Aided Diagnosis System for Breast Cancer Combining Mammography and Proteomics

    Science.gov (United States)

    2007-05-01

    for sonography,” Ultrasound Med. Biol. 26, 405-411 2000. 20K. Horsch, M. L. Giger, L. A. Venta , and C. J. Vyborny, “Computerized diagnosis of breast...lesions on ultrasound,” Med. Phys. 29, 157-164 2002. 21K. Horsch, M. L. Giger, C. J. Vyborny, and L. A. Venta , “Performance of computer-aided...Horsch K, Giger ML, Vyborny CJ, Venta LA. Performance of computer-aided diagnosis in the interpretation of lesions on breast sonography. Acad Radiol

  8. Comparison of Paravertebral Block by Anatomic Landmark Technique to Ultrasound-Guided Paravertebral Block for Breast Surgery Anesthesia: A Randomized Controlled Trial.

    Science.gov (United States)

    Patnaik, Rupali; Chhabra, Anjolie; Subramaniam, Rajeshwari; Arora, Mahesh K; Goswami, Devalina; Srivastava, Anurag; Seenu, Vuthaluru; Dhar, Anita

    2018-05-01

    Paravertebral block (PVB) is an established technique for providing anesthesia for breast surgery. The primary objective was to compare anatomical landmark technique (ALT) to the ultrasound-guided (USG) PVB block for providing surgical anesthesia. Secondary objectives included comparison of perioperative analgesia and complications. This randomized, controlled, observer-blinded study included 72 females, aged 18 to 65 years, American Society of Anesthesiologists physical status I or II, undergoing elective unilateral breast surgery. Study participants were randomized to the ALT group or USG group. Ipsilateral PVB was performed with the respective technique from T1 to T6. Five milliliters of local anesthetic mixture (0.5% ropivacaine, 5 μg/mL adrenaline, 1 μg/kg clonidine) was administered at each level. Paravertebral catheter was inserted at T4/T3 level. After confirming sensory loss, patients were taken up for surgery with propofol sedation (20-50 μg/kg per minute). More patients in the USG group (34/36 [94.44%]) had a successful block as compared with the ALT group (26/36 [72.22%]) (P = 0.024). Difference in proportion was 18.1 (95% confidence interval, 0.15-36.0) (P = 0.024) after adjustment for age. More dermatomes were blocked in the USG group (P = 0.0018) with less sparing of upper T2 and T3 dermatomes (P = 0.003, P = 0.006, respectively). Median time to first postoperative analgesic requirement was 502.5 minutes (range, 195-1440 minutes) in the USG group versus 377.5 minutes (range, 215-1440 minutes) in the ALT group. Pain at rest and movement 2 and 4 hours postoperatively and number of catheter top-ups in 24 hours postoperatively were lesser in the USG group (P = 0.012). Complications were comparable. Ultrasound-guided PVB provided better anesthesia and perioperative analgesia than the landmark technique for breast surgery. The trial was registered retrospectively at the Clinical Trial Registry of India, CTRI/2015/05/005774.

  9. Tc-99m Methoxy Isobutyl Isonitrile (MIBI) scintimammography for detection of loco-regional recurrence of breast cancer: A comparative study of scintimammography, X-ray mammography and breast ultrasound imaging

    International Nuclear Information System (INIS)

    Usmani, S.; Niaz, K.; Ahmed, N.; Niyaz, K.; Khan, H.A.; Javed, A.; Mohannadi, S.A.; Huda, F.A.

    2007-01-01

    Breast cancer is the most common cancer among women and the second leading cause of death in women after lung cancer. Local recurrence rate is about 1-2% per year. It is important to find a sensitive and accurate diagnostic method for early detection of recurrent tumor for planning subsequent management. The principal aim of the present study was to assess the utility of Tc-99m MIBI scintimammography in the detection of loco-regional recurrence of breast cancer in comparison with the conventionally used methods like x-ray mammography and ultrasonography. A total number of 42 patients (Age: mean= 45.55 yrs; median = 43.5; range, 22-77 yrs) suspected to have loco-regional recurrence of breast cancer on the basis of clinical examination and/or conventional imaging procedures were included in this study. All patients were subjected to planar scintimammography (SMM), SPECT imaging of the breast, x-ray mammography and Ultrasound scanning. The results were correlated with the final diagnosis arrived at by fine needle aspiration cytology (FNAC), core biopsy or definite wide local excision. Sensitivity (SEN), specificity (SPE), positive predictive value (PPV), negative predictive value (NPV) and accuracy (ACC) of scintimammography in the diagnosis of recurrent disease were found to be 82.75, 92.3, 96.0, 70.58 and 85.71% respectively; compared to 45.83, 66.6, 78.57, 31.57, 51.51 for x-ray mammography and 65.51, 69.23, 82.6, 47.36, 66.66 for Ultrasonography. Scintimammography results were correlated with x-ray mammography and ultrasonography by applying Pearson correlation. No significant correlation was found between SMM and XMM (r=0.27) or SMM and US (r=0.23). Based on the results of this study it is concluded that SMM has better diagnostic accuracy than mammography and ultrasonography in the detection of loco-regional recurrence of breast cancer. (author)

  10. The Contribution of Three-Dimensional Power Doppler Imaging in the Preoperative Assessment of Breast Tumors: A Preliminary Report

    Directory of Open Access Journals (Sweden)

    K. Kalmantis

    2009-01-01

    Methods. One hundred and twenty five women with clinically or mammographically suspicious findings were referred for 3D Power Doppler ultrasound prior to surgery. Histological diagnosis was conducted after surgery and compared with ultrasound findings. Sonographic criteria used for breast cancer diagnosis were based on a system that included morphological characteristics and criteria of the vascular pattern of a breast mass by Power Doppler imaging. Results. Seventy-two lesions were histopathologically diagnosed as benign and 53 tumors as malignant. Three-dimensional ultrasound identified 49 out of 53 histologically confirmed breast cancers resulting in a sensitivity of 92.4% and a specificity of 86.1% in diagnosing breast malignancy (PPV: 0.83, NPV:0.94. Conclusions. 3D ultrasonography is a valuable tool in identifying preoperatively the possibility of a tumor to be malignant.

  11. Ultrasound-guided cryoablation of breast fibroadenoma: a pilot trial.

    Science.gov (United States)

    Golatta, Michael; Harcos, Aba; Pavlista, David; Danes, Jan; Klein, Rafi; Simovich, Paola; Gruber, Ines; Hahn, Markus

    2015-06-01

    The aim of the study was to evaluate cryoablation (CA) under ultrasound guidance in the office setting with liquid nitrogen system for patients with fibroadenoma (FA). For this prospective multicenter trial, an office-based cryosurgical system was used to treat histological confirmed benign FA with a maximum dimension of 3 cm. Sixty CA procedures were performed under ultrasound guidance. A freeze-thaw-freeze treatment cycle was performed according to the size of the FA. During the CA procedure continuous ultrasound monitoring was performed, verifying engulfment of the FA. Patients attended four follow-up visits at 1 week, 3, 6 months and 1 year and underwent ultrasound, physical examination and photography. Data were collected and analyzed in 60 cases. 59 of 60 FA (98 %) were fully engulfed by the ice ball. No serious adverse events occurred related to the IceSense3 system. At the 1-year follow-up, the FAs were gone in 93% of the cases. Prior to CA procedure, 76% of the FAs were palpable. Afterwards in some cases (22%), a scar/cryo lesion was palpable. 28% of the patients reported pain, described as mild or moderate, compared to 2% after 1 year. Cosmetic results at 12 months follow-up were reported as good or excellent in 100% by physician and in 97% by patients. The cryodestruction of the FA using liquid nitrogen system proved functional and safe, while showing meaningful reduction in volume, palpability, pain and cosmetic satisfying outcomes.

  12. The effectiveness of a mobile application for the development of palpation and ultrasound imaging skills to supplement the traditional learning of physiotherapy students.

    Science.gov (United States)

    Fernández-Lao, Carolina; Cantarero-Villanueva, Irene; Galiano-Castillo, Noelia; Caro-Morán, Elena; Díaz-Rodríguez, Lourdes; Arroyo-Morales, Manuel

    2016-10-19

    Mobile learning (m-learning) has becoming very popular in education due to the rapidly advancing technology in our society. The potentials of the mobile applications should be used to enhance the education process. Few mobile applications have been designed to complement the study of physical therapy skills for physiotherapy students. The aim of this study was to investigate whether a mobile application, as a supplement to traditional learning, is useful for physiotherapy students in the acquisition of palpation and ultrasound skills in the shoulder area. Forty-nine students participated in this single-blinded, randomized controlled study. They were randomly distributed into two groups: experimental, with free access to the mobile application; and control, with access to traditional learning materials on the topic. Objective structured clinical evaluation (OSCE) and multiple-choice questionnaire (MCQ) were used to assess the educational intervention. Then, we also assessed the time taken to get a reliable ultrasound image and to localize a specific shoulder structure by palpation. There was no significant intergroup difference in the acquisition of theoretical knowledge (p = .089). Scores were significantly higher in the experimental group than in the control group for the majority items in the ultrasound assessment; positioning of patient (p physiotherapy students.

  13. Early Diagnosis of Breast Cancer.

    Science.gov (United States)

    Wang, Lulu

    2017-07-05

    Early-stage cancer detection could reduce breast cancer death rates significantly in the long-term. The most critical point for best prognosis is to identify early-stage cancer cells. Investigators have studied many breast diagnostic approaches, including mammography, magnetic resonance imaging, ultrasound, computerized tomography, positron emission tomography and biopsy. However, these techniques have some limitations such as being expensive, time consuming and not suitable for young women. Developing a high-sensitive and rapid early-stage breast cancer diagnostic method is urgent. In recent years, investigators have paid their attention in the development of biosensors to detect breast cancer using different biomarkers. Apart from biosensors and biomarkers, microwave imaging techniques have also been intensely studied as a promising diagnostic tool for rapid and cost-effective early-stage breast cancer detection. This paper aims to provide an overview on recent important achievements in breast screening methods (particularly on microwave imaging) and breast biomarkers along with biosensors for rapidly diagnosing breast cancer.

  14. Development of an MRI/x-ray/ultrasound compatible marker for pre-operative breast tumour localization

    International Nuclear Information System (INIS)

    Li Yangmei; Wang, Jianxiong; Holloway, Claire; Plewes, Donald B

    2005-01-01

    This paper describes an in vitro investigation into the composition, structure and development of an magnetic resonance imaging (MRI), ultrasound (US) and x-ray imaging compatible marker for breast tumour localization. The marker is composed of 0.4-0.6 mm glass and iron-containing aluminium microspheres suspended in a gelatin matrix. The final form of the marker is a cylindrical shape 7 mm long with 2.05 mm diameter to facilitate delivery through a 12 gauge biopsy needle. To get optimal reflectivity for the US contrast, the glass microsphere concentration was found to be 40% by weight. US contrast is independent of marker orientation and the cylindrical shape made its US signal appearance distinctive thus ensuring confident identification. To control the MRI contrast, iron content was varied to generate a clear and local susceptibility signal void to reflect the marker position. Optimal iron content was found to be 52 μg iron which produced a clear signal void in spoiled gradient recalled MR images. The appearance of the susceptibility artefact is determined by the marker's shape, orientation and echo time. The final marker produces a dark artefact in MRI while appears as a clear hyperintense structure with acoustic shadowing in US images. The x-ray image showed the marker as a radio-opaque structure. This in vitro study demonstrates that the marker forms an alternative to traditional wire localization currently used for breast surgical procedures and creates new opportunities for US guided surgical procedures

  15. Tomosynthesis as a screening tool for breast cancer: A systematic review

    International Nuclear Information System (INIS)

    Coop, P.; Cowling, C.; Lawson, C.

    2016-01-01

    Background: Mammography is an important screening tool for reducing breast cancer mortality. Digital breast tomosynthesis (DBT) can potentially be integrated with mammography to aid in cancer detection. Method: Using the PRISMA guidelines, a systematic review of current literature was conducted to identify issues relating to the use of tomosynthesis as a screening tool together with mammography. Findings: Using tomosynthesis with digital mammography (DM) increases breast cancer detection, reduces recall rates and increases the positive predictive value of those cases recalled. Invasive cancer detection is significantly improved in tomosynthesis compared to mammography, and has improved success for women with heterogeneous or extremely dense breasts. Conclusion: Tomosynthesis reduces some limitations of mammography at the time of screening that until recently were most often addressed by ultrasound at later work-up. Tomosynthesis can potentially be adopted alongside mammography as a screening tool. - Highlights: • Using tomosynthesis with digital mammography increases breast cancer detection. • Tomosynthesis has improved detection for women with extremely dense breasts. • Tomosynthesis reduces the need for ultrasound to address mammography limitations. • When Tomosynthesis is combined with mammography, recall rates are reduced.

  16. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: an analysis for Austria.

    Science.gov (United States)

    Gruber, R; Walter, E; Helbich, T H

    2010-06-01

    To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Overall cost savings for US-guided LCBB over OSB were euro 977 (euro 2,337/euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were euro 1,542 (euro 2,600/euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be euro 18.5 million. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  17. Ultrasonic elastography features of phyllodes tumors of the breast: a clinical research.

    Directory of Open Access Journals (Sweden)

    Lu-Jing Li

    Full Text Available The purpose of this study was to analyze the ultrasonic elastography features of phyllodes tumors of the breast comparing with fibroadenomas. A retrospective database was queried for the patients diagnosed as phyllodes tumors and fibroadenomas at Sun Yat-sen Memorial Hospital from January 2008 to August 2012. Three hundred and fifty lesions from 323 consecutive patients were included in the study. All the cases were examined by conventional ultrasonography and ultrasound elastography. Ultrasound elastography was used to calculate strain ratio of the lesions with bilateral breast tissue at the same depth as reference. There were 36 phyllodes tumors (27 benign, 8 borderline, 1 malignant and 314 fibroadenomas (158 the pericanalicular type, 103 the intracanalicular type, 53 other special types. The strain ratio for phyllodes tumors (3.19 ± 2.33 was significantly higher than for fibroadenomas (1.69 ± 0.88 (p<0.05. The Spearman(.s correlation coefficient between strain ratio of ultrasound elastography and pathological groups was significant, with a value of 0.17 (p<0.05. Ultrasound elastography could provide additional information to differentiate phyllodes tumors from fibroadenoma in breast.

  18. Examining intentions to use CoQ10 amongst breast cancer patients.

    Science.gov (United States)

    Hill, Gina Jarman; Shriver, Brent J; Arnett, Dennis B

    2006-01-01

    To determine factors that influence breast cancer patients' intentions to supplement with CoQ10. A survey based upon the expanded rational expectations intentions model was completed by breast cancer outpatients (N=160). A significantly positive relationship existed between referent other (the influence specific people have in terms of an individual's behavior) and subjective norm (subject's perception of how people view a behavior). Beliefs, referent other, attitude, and subjective norm did have a significant effect on intention to use CoQ10. Health practitioners may address supplementation with breast cancer patients with a better understanding of what factors impact supplement use.

  19. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    Science.gov (United States)

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. Microwave Imaging for Breast Cancer Detection

    DEFF Research Database (Denmark)

    Rubæk, Tonny; Fhager, Andreas; Jensen, Peter Damsgaard

    2011-01-01

    Still more research groups are promoting microwave imaging as a viable supplement or substitution to more conventional imaging modalities. A widespread approach for microwave imaging of the breast is tomographic imaging in which one seeks to reconstruct the distributions of permittivity and condu......Still more research groups are promoting microwave imaging as a viable supplement or substitution to more conventional imaging modalities. A widespread approach for microwave imaging of the breast is tomographic imaging in which one seeks to reconstruct the distributions of permittivity...... and conductivity in the breast. In this paper two nonlinear tomographic algorithms are compared – one is a single-frequency algorithm and the other is a time-domain algorithm....

  1. Characterization of Breast Lesions: Comparison of Digital Breast Tomosynthesis and Ultrasonography

    International Nuclear Information System (INIS)

    Kim, Sun Ah; Chang, Jung Min; Cho, Nariya; Yi, Ann; Moon, Woo Kyung

    2015-01-01

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and conventional breast ultrasound (US) to characterize breast lesions as benign or malignant. A total of 332 women, presenting for screening examinations or for breast biopsy between March and June 2012 were recruited to undergo digital mammography (DM), DBT, and breast US examination. Among them, 113 patients with 119 breast lesions depicted on DM were finally included. Three blinded radiologists performed an enriched reader study and reviewed the DBT and US images. Each reader analyzed the lesions in random order, assigned Breast Imaging Reporting and Data System (BI-RADS) descriptors, rated the images for the likelihood of malignancy (%) and made a BI-RADS final assessment. Diagnostic accuracy, as assessed by the area under the receiver operating characteristic curve, sensitivity, and specificity of DBT and US were compared. Among the 119 breast lesions depicted on DM, 75 were malignant and the remaining 44 were benign. The average diagnostic performance for characterizing breast lesions as benign or malignant in terms of area under the curve was 0.899 for DBT and 0.914 for US (p = 0.394). Mean sensitivity (97.3% vs. 98.7%, p = 0.508) and specificity (44.7% vs. 39.4%, p = 0.360) were also not significantly different. Digital breast tomosynthesis may provide similar reader lesion characterization performance to that of US for breast lesions depicted on DM

  2. Characterization of Breast Lesions: Comparison of Digital Breast Tomosynthesis and Ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Ah [Department of Radiology, Human Medical Imaging & Intervention Center, Seoul 135-120 (Korea, Republic of); Chang, Jung Min; Cho, Nariya [Department of Radiology, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of); Yi, Ann [Department of Radiology, Seoul National University Hospital Healthcare System Gangnam Center, Seoul 135-984 (Korea, Republic of); Moon, Woo Kyung [Department of Radiology, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of)

    2015-11-01

    To compare the diagnostic performance of digital breast tomosynthesis (DBT) and conventional breast ultrasound (US) to characterize breast lesions as benign or malignant. A total of 332 women, presenting for screening examinations or for breast biopsy between March and June 2012 were recruited to undergo digital mammography (DM), DBT, and breast US examination. Among them, 113 patients with 119 breast lesions depicted on DM were finally included. Three blinded radiologists performed an enriched reader study and reviewed the DBT and US images. Each reader analyzed the lesions in random order, assigned Breast Imaging Reporting and Data System (BI-RADS) descriptors, rated the images for the likelihood of malignancy (%) and made a BI-RADS final assessment. Diagnostic accuracy, as assessed by the area under the receiver operating characteristic curve, sensitivity, and specificity of DBT and US were compared. Among the 119 breast lesions depicted on DM, 75 were malignant and the remaining 44 were benign. The average diagnostic performance for characterizing breast lesions as benign or malignant in terms of area under the curve was 0.899 for DBT and 0.914 for US (p = 0.394). Mean sensitivity (97.3% vs. 98.7%, p = 0.508) and specificity (44.7% vs. 39.4%, p = 0.360) were also not significantly different. Digital breast tomosynthesis may provide similar reader lesion characterization performance to that of US for breast lesions depicted on DM.

  3. Advanced ultrasound applications in the assessment of renal transplants: contrast-enhanced ultrasound, elastography, and B-flow.

    Science.gov (United States)

    Morgan, Tara A; Jha, Priyanka; Poder, Liina; Weinstein, Stefanie

    2018-04-09

    Ultrasound is routinely used as the first imaging exam for evaluation of renal transplants and can identify most major surgical complications and evaluate vascularity with color Doppler. Ultrasound is limited, however, in the detection of parenchymal disease processes and Doppler evaluation is also prone to technical errors. Multiple new ultrasound applications have been developed and are under ongoing investigation which could add additional diagnostic capability to the routine ultrasound exam with minimal additional time, cost, and patient risk. Contrast-enhanced ultrasound (CEUS) can be used off-label in the transplant kidney, and can assist in detection of infection, trauma, and vascular complications. CEUS also can demonstrate perfusion of the transplant assessed quantitatively with generation of time-intensity curves. Future directions of CEUS include monitoring treatment response and microbubble targeted medication delivery. Elastography is an ultrasound application that can detect changes in tissue elasticity, which is useful to diagnose diffuse parenchymal disease, such as fibrosis, otherwise unrecognizable with ultrasound. Elastography has been successfully applied in other organs including the liver, thyroid, and breast; however, it is still under development for use in the transplant kidney. Unique properties of the transplant kidney including its heterogeneity, anatomic location, and other technical factors present challenges in the development of reference standard measurements. Lastly, B-flow imaging is a flow application derived from B-mode. This application can show the true lumen size of a vessel which is useful to depict vascular anatomy and bypasses some of the pitfalls of color Doppler such as demonstration of slow flow.

  4. Comparison between automated breast volume scanner (ABVS) versus hand-held ultrasound as a second look procedure after magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Girometti, Rossano; Zanotel, Martina; Londero, Viviana; Bazzocchi, Massimo; Zuiani, Chiara [University of Udine, Azienda Ospedaliero-Universitaria, ' S. Maria della Misericordia' , Institute of Diagnostic Radiology, Department of Medical and Biological Sciences, Udine (Italy)

    2017-09-15

    To evaluate the agreement between automated breast volume scanner (ABVS) and conventional ultrasound (US) as a second-look (SL) tool for assessing additional findings found on MRI. Over a 7-month period, we prospectively assigned to SL-US and SL-ABVS all patients undergoing 1.5 T breast MRI in whom additional findings were found. Five experienced breast radiologists independently interpreted SL-US and SL-ABVS in blinded sessions to evaluate the detection rate of MRI findings and assign them to BI-RADS categories. We calculated the agreement between the two methods in assessing MRI findings as significant (BI-RADS 3-5) versus not significant (BI-RADS 1-2), as well as their cancer detection rate. In a population of 131 patients, SL-ABVS and SL-US showed a comparable detection rate of MRI findings (69.3 vs. 71.5%) (p > 0.05; McNemar test), with an almost perfect agreement in assessing them as significant or not (k = 0.94). This translated into a comparably high cancer detection rate (83.8% for SL-ABVS vs. 87.0% for SL-US). Only 1/31 cancers was missed by SL-ABVS. SL-ABVS and SL-US are nearly equivalent in assessing the significance of MRI findings, leading to a comparable cancer detection rate. SL-ABVS has the potential to replace SL-US in the SL scenario. (orig.)

  5. Comparison between automated breast volume scanner (ABVS) versus hand-held ultrasound as a second look procedure after magnetic resonance imaging

    International Nuclear Information System (INIS)

    Girometti, Rossano; Zanotel, Martina; Londero, Viviana; Bazzocchi, Massimo; Zuiani, Chiara

    2017-01-01

    To evaluate the agreement between automated breast volume scanner (ABVS) and conventional ultrasound (US) as a second-look (SL) tool for assessing additional findings found on MRI. Over a 7-month period, we prospectively assigned to SL-US and SL-ABVS all patients undergoing 1.5 T breast MRI in whom additional findings were found. Five experienced breast radiologists independently interpreted SL-US and SL-ABVS in blinded sessions to evaluate the detection rate of MRI findings and assign them to BI-RADS categories. We calculated the agreement between the two methods in assessing MRI findings as significant (BI-RADS 3-5) versus not significant (BI-RADS 1-2), as well as their cancer detection rate. In a population of 131 patients, SL-ABVS and SL-US showed a comparable detection rate of MRI findings (69.3 vs. 71.5%) (p > 0.05; McNemar test), with an almost perfect agreement in assessing them as significant or not (k = 0.94). This translated into a comparably high cancer detection rate (83.8% for SL-ABVS vs. 87.0% for SL-US). Only 1/31 cancers was missed by SL-ABVS. SL-ABVS and SL-US are nearly equivalent in assessing the significance of MRI findings, leading to a comparable cancer detection rate. SL-ABVS has the potential to replace SL-US in the SL scenario. (orig.)

  6. Measurement of breast volume is a useful supplement to select candidates for surgical breast reduction

    DEFF Research Database (Denmark)

    Ikander, Peder; Drejøe, Jennifer Berg; Lumholt, Pavia

    2014-01-01

    for breast reduction surgery, thus establishing a standard decision basis that can be shared by surgeons and departments to secure patients fair and equal treatment opportunities. MATERIAL AND METHODS: A total of 427 patients who were referred to three Danish public hospitals with breast hypertrophy...... in the period from January 2007 to March 2011 were included prospectively in the study. The patients' subjective complaints, height, weight and standard breast measurements were registered as well as the decision for or against surgery. Breast volume was measured using transparent plastic cups. RESULTS: Cut......-off values for breast volume were calculated based on whether or not the patients were offered reduction surgery. Most patients (93%) with a breast volume below 800 cc were not offered surgery, while most with a volume exceeding 900 cc were offered surgery (94%). In the grey zone between 800 and 900 cc...

  7. Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors

    International Nuclear Information System (INIS)

    Kettenbach, Joachim; Helbich, Thomas H.; Huber, Sabine; Zuna, Ivan; Dock, Wolfgang

    2005-01-01

    Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound

  8. Seeding after ultrasound-guided percutaneous biopsy of liver metastases in patients with colorectal or breast cancer

    DEFF Research Database (Denmark)

    Chen, Inna; Lorentzen, Torben; Linnemann, Dorte

    2016-01-01

    BACKGROUND: Neoplasm seeding is a serious complication after liver metastases biopsy. Reported incidences vary between 10% and 19% for colorectal cancer (CRC) and are unknown for breast cancer (BC). The aim of this retrospective study was to determine the frequency of tumor seeding after ultrasound...... retrospectively reviewed. The endpoint was the development of abdominal wall recurrence following liver biopsy. RESULTS: Of total 2981 biopsies we identified 278 patients with CRC and 155 patients with BC biopsy-verified liver metastases. During the median follow-up of 25 months after biopsy (range 3-253 months......), no seeding was recorded in patients with BC. Within the median follow-up of 34 months (3-111 months), seeding was registered in 17/278 (6%) of patients with CRC; three patients of 278 (1%) had undoubtedly biopsy-related seeding, which became apparent six, nine, and 26 months after biopsy, respectively...

  9. Pre-Operative Planning Using Real-Time Virtual Sonography, an MRI/Ultrasound Image Fusion Technique, for Breast-Conserving Surgery in Patients with Non-Mass Enhancement on Breast MRI: A Preliminary Study.

    Science.gov (United States)

    Ando, Takahito; Ito, Yukie; Ido, Mirai; Osawa, Manami; Kousaka, Junko; Mouri, Yukako; Fujii, Kimihito; Nakano, Shogo; Kimura, Junko; Ishiguchi, Tsuneo; Watanebe, Rie; Imai, Tsuneo; Fukutomi, Takashi

    2018-07-01

    The purpose of this retrospective study was to evaluate the effect of pre-operative planning using real-time virtual sonography (RVS), a magnetic resonance imaging (MRI)/ultrasound (US) image fusion technique on breast-conserving surgery (BCS) in patients with non-mass enhancement (NME) on breast MRI. Between 2011 and 2015, we enrolled 12 consecutive patients who had lesions with NME that exceeded the US hypo-echoic area, in which it was particularly difficult to evaluate the tumor margin. During pre-operative planning before breast-conserving surgery, RVS was used to delineate the enhancing area on the breast surface after additional supine breast MRI was performed. We analyzed both the surgical margin positivity rate and the re-operation rate. All NME lesions corresponded to the index cancer. In all patients, the diameter of the NME lesion was greater than that of the hypo-echoic lesion. The median diameters of the NME and hypo-echoic lesions were 24 mm (range: 12-39 mm) and 8.0 mm (range: 4.9-18 mm), respectively (p = 0.0002). After RVS-derived skin marking was performed on the surface of the affected breast, lumpectomy and quadrantectomy were conducted in 7 and 5 patients, respectively. The surgical margins were negative in 10 (83%) patients. Two patients with positive margins were found to have ductal carcinoma in situ in 1 duct each, 2.4 and 3.2 mm from the resection margin, respectively. None of the patients required additional resection. Although further prospective studies are required, the findings of our preliminary study suggest that it is very well possible that the use of RVS-derived skin marking during pre-operative planning for BCS in patients with NME would have resulted in surgical outcomes similar to or better than those obtained without the use of such marking. Copyright © 2018. Published by Elsevier Inc.

  10. Evaluation of lymph node status after neoadjuvant chemotherapy in breast cancer patients: comparison of diagnostic performance of ultrasound, MRI and ¹⁸F-FDG PET/CT.

    Science.gov (United States)

    You, S; Kang, D K; Jung, Y S; An, Y-S; Jeon, G S; Kim, T H

    2015-08-01

    To evaluate the diagnostic performance of ultrasound, MRI and fluorine-18 fludeoxyglucose positron emission tomography (¹⁸F-FDG PET)/CT for the diagnosis of metastatic axillary lymph node (ALN) after neoadjuvant chemotherapy (NAC) and to find out histopathological factors affecting the diagnostic performance of these imaging modalities. From January 2012 to November 2014, 191 consecutive patients with breast cancer who underwent NAC before surgery were retrospectively reviewed. We included 139 patients with ALN metastasis that was confirmed on fine needle aspiration or core needle biopsy at initial diagnosis. After NAC, 39 (28%) patients showed negative conversion of ALN on surgical specimens of sentinel lymph node (LN) or ALN. The sensitivity of ultrasound, MRI and PET/CT was 50% (48/96), 72% (70/97) and 22% (16/73), respectively. The specificity of ultrasound, MRI and PET/CT was 77% (30/39), 54% (21/39) and 85% (22/26), respectively. The Az value of combination of ultrasound and PET/CT was the highest (0.634) followed by ultrasound (0.626) and combination of ultrasound, MRI and PET/CT (0.617). The size of tumour deposit in LN and oestrogen receptor was significantly associated with the diagnostic performance of ultrasound (p performance of PET/CT (p = 0.023, p = 0.002, p = 0.036, p = 0.044 and p = 0.008, respectively). On multivariate logistic regression analysis, size of tumour deposit within LN was identified as being independently associated with diagnostic performance of ultrasound [odds ratio, 13.07; 95% confidence interval (CI), 2.95-57.96] and PET/CT (odds ratio, 6.47; 95% CI, 1.407-29.737). Combination of three imaging modalities showed the highest sensitivity, and PET/CT showed the highest specificity for the evaluation of ALN metastasis after NAC. Ultrasound alone or combination of ultrasound and PET/CT showed the highest positive-predictive value. The size of tumour deposit within ALN was significantly associated with

  11. Radiologic findings of male breast cancer: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Jeong Geun; Park, Kyung Joo; Han, Chun Hwan; Lee, Joo Hyuk [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of)

    1994-10-15

    Male breast cancer is an uncommon disease with an incidence of 1 percent of all breast cancers. Male breast cancer usually appears as a small mass with well defined contour which is eccentrically located in relation to the nipple on mammogram. We report a case of breast cancer in a 51 year old man with mammographic appearance of large hyperdense mass with nipple inversion and axillary lymphadenopathy, gray-scale sonographic finding of homogeneous solid mass and multiple tumor vessels within the mass on color Doppler ultrasound.

  12. 30-year-old woman with breast mass

    International Nuclear Information System (INIS)

    Beaulieu, C.; Kennedy, B.; Kopans, D.B.

    1984-01-01

    This 30-year-old woman with a history of renal transplant requiring vigorous medication with Prednisone and Imuran felt a left breast lump after minor trauma. Her only complaint was itching over the area of the lump. Bilateral mammography was performed and demonstrated an 8 x 8 cm well circumscribed mass in the anterior aspect of the left breast. This finding was nonspecific. Ultrasound was performed

  13. Sonographic features of invasive ductal breast carcinomas predictive of malignancy grade.

    Science.gov (United States)

    Gupta, Kanika; Kumaresan, Meenakshisundaram; Venkatesan, Bhuvaneswari; Chandra, Tushar; Patil, Aruna; Menon, Maya

    2018-01-01

    Assessment of individual sonographic features provides vital clues about the biological behavior of breast masses and can assist in determining histological grade of malignancy and thereby prognosis. Assessment of individual sonographic features of biopsy proven invasive ductal breast carcinomas as predictors of malignancy grade. A retrospective analysis of sonographic findings of 103 biopsy proven invasive ductal breast carcinomas. Tumor characteristics on gray-scale ultrasound and color flow were assessed using American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) Atlas Fifth Edition. The sonographic findings of masses were individually correlated with their histopathologic grades. Chi square test, ordinal regression, and Goodman and Kruskal tau test. Breast mass showing reversal/lack of diastolic flow has a high probability of belonging to histological high grade tumor ( β 1.566, P 0.0001 ). The masses with abrupt interface boundary are more likely grade 3 ( β 1.524, P 0.001 ) in comparison to masses with echogenic halos. The suspicious calcifications present in and outside the mass is a finding associated with histologically high grade tumors. The invasive ductal carcinomas (IDCs) with complex solid and cystic echotexture are more likely to be of high histological grade ( β 1.146, P 0.04 ) as compared to masses with hypoechoic echotexture. Certain ultrasound features are associated with tumor grade on histopathology. If the radiologist is cognizant of these sonographic features, ultrasound can be a potent modality for predicting histopathological grade of IDCs of the breast, especially in settings where advanced tests such as receptor and molecular analyses are limited.

  14. Evaluating Surveillance Breast Imaging and Biopsy in Older Breast Cancer Survivors

    Directory of Open Access Journals (Sweden)

    Tracy Onega

    2012-01-01

    Full Text Available Background. Patterns of surveillance among breast cancer survivors are not well characterized and lack evidence-based practice guidelines, particularly for imaging modalities other than mammography. We characterized breast imaging and related biopsy longitudinally among breast cancer survivors in relation to women’s characteristics. Methods. Using data from a state-wide (New Hampshire breast cancer screening registry linked to Medicare claims, we examined use of mammography, ultrasound (US, magnetic resonance imaging (MRI, and biopsy among breast cancer survivors. We used generalized estimating equations (GEE to model associations of breast surveillance with women’s characteristics. Results. The proportion of women with mammography was high over the follow-up period (81.5% at 78 months, but use of US or MRI was much lower (8.0%—first follow-up window, 4.7% by 78 months. Biopsy use was consistent throughout surveillance periods (7.4%–9.4%. Surveillance was lower among older women and for those with a higher stage of diagnosis. Primary therapy was significantly associated with greater likelihood of breast surveillance. Conclusions. Breast cancer surveillance patterns for mammography, US, MRI, and related biopsy seem to be associated with age, stage, and treatment, but need a larger evidence-base for clinical recommendations.

  15. Ultrasound elastographic techniques in focal liver lesions.

    Science.gov (United States)

    Conti, Clara Benedetta; Cavalcoli, Federica; Fraquelli, Mirella; Conte, Dario; Massironi, Sara

    2016-03-07

    Elastographic techniques are new ultrasound-based imaging techniques developed to estimate tissue deformability/stiffness. Several ultrasound elastographic approaches have been developed, such as static elastography, transient elastography and acoustic radiation force imaging methods, which include point shear wave and shear wave imaging elastography. The application of these methods in clinical practice aims at estimating the mechanical tissues properties. One of the main settings for the application of these tools has been liver stiffness assessment in chronic liver disease, which has been studied mainly using transient elastography. Another field of application for these techniques is the assessment of focal lesions, detected by ultrasound in organs such as pancreas, prostate, breast, thyroid, lymph nodes. Considering the frequency and importance of the detection of focal liver lesions through routine ultrasound, some studies have also aimed to assess the role that elestography can play in studying the stiffness of different types of liver lesions, in order to predict their nature and thus offer valuable non-invasive methods for the diagnosis of liver masses.

  16. Primary extraskeletal Ewing's sarcoma/primitive neuroectodermal tumor of breast

    Directory of Open Access Journals (Sweden)

    Smita Srivastava

    2016-01-01

    Full Text Available Extraskeletal Ewing's sarcoma (EES is a rare soft tissue tumor that is morphologically indistinguishable from skeletal ES. We report a case of a 25-year-old female with recurrent EES/primitive neuroectodermal tumor of right breast with imaging findings on mammogram, ultrasound, magnetic resonance imaging breast, and positron emission tomography–computed tomography.

  17. Isolated breast vasculitis manifested as breast edema with suggestive sonographic findings: a case report with imaging findings.

    Science.gov (United States)

    Lee, Ji Young; Joo, Mee

    2017-04-01

    Early diagnosis of breast vasculitis (BV) is difficult because this condition is rare and occasionally mimics breast cancer clinically or radiologically. It may present as systemic disease or as an isolated lesion in the breast, without systemic evidence. When vasculitis appears in the breast, it also might manifest as a tumor-like lesion, and in previous cases, tissue acquisition was needed for confirmation of the diagnosis because of BV's resemblance to inflammatory breast cancer. We report a case of isolated BV that was suspected of being inflammatory breast cancer clinically, but manifested as bilateral breast edema on mammography. In this case, sonographic findings included not only nonspecific edema findings that might be seen in other cases, but also suggestive findings of hypoechoic circumferential arterial wall thickening with perivascular fat infiltrations that are similar to the halo sign in large arteries but have not been reported in the breast. These are helpful for presumptive diagnosis of BV using ultrasound.

  18. Risk-benefit analysis of preoperative breast MRI in patients with primary breast cancer

    International Nuclear Information System (INIS)

    Siegmann, K.C.; Baur, A.; Vogel, U.; Kraemer, B.; Hahn, M.; Claussen, C.D.

    2009-01-01

    Aim: To analyse and compare the risks and benefits of preoperative breast MRI (BMRI) in patients with primary breast cancer (PBC), and to determine the influence of mammographic breast density (BD) and histological tumour type (TT). Materials and Methods: One hundred and nineteen patients who underwent preoperative bilateral breast MRI for staging of PBC during a 1-year period from July 2005 to August 2006 were prospectively evaluated. Changes in clinical management due to BMRI findings were recorded. MRI-detected lesions were correlated with histology. Additional MRI-detected malignant lesions and spared additional biopsies because of negative MRI in case of unclear ultrasound findings were determined as beneficial for the patient. Biopsies of benign MRI detected lesions were defined as disadvantageous. The influence of BD (ACR 1-4) and TT on the change in clinical management and patient benefit was evaluated. Results: The findings of the BMRI examinations changed the clinical management in 48 patients (40.3%). Seventeen women underwent mastectomy instead of breast conservation, eight patients underwent extended excision, 21 additional lesions were clarified by MRI intervention, and two ultrasound-detected lesions were not biopsied because of negative MRI. Histologically malignant additional or extended biopsies (n = 34) and two cases of spared biopsies resulted in 36 (30.3%) women who benefited from preoperative BMRI. Twelve patients (10.1%) had additional biopsies of MRI-detected benign lesions, and therefore, had an unfavourable outcome due to BMRI. The change in clinical management and patient benefit were independent of BD and TT (p > 0.05). Conclusion: Preoperative BMRI was beneficial for 30.3% of 119 patients with PBC. The percentage of additional biopsies of benign lesions (10.1%) seems acceptable

  19. Multiparametric MR imaging of the breast after augmentation and oncoplastic surgery

    International Nuclear Information System (INIS)

    Ivanov, V.; Kirova, G.

    2015-01-01

    Full text: Evaluation of breast lesions in patients after augmentation and oncoplastic surgery are difficult and uncertain with ultrasound and mammography. These two methods give us information of the lesions nature, but this information has low specificity. Morphologic MRI sequences enable to an exact assessment the nature of the lesions high sensitivity, but with low specificity. To enhance security in the evaluation of the lesions new series as DCE MRI, DWI and MRI proton spectroscopy have to be added. Teaching points: to learn how and when to use multiparametric MRI for evaluation of breast lesion after augmentation and oncoplastic surgery; to present the multiparametric MRI protocol for evaluation of malignant breast lesion after augmentation and oncoplastic surgery; to discuss the main signs differentiating benign from malignant breast lesions based on the features on multiparametric MR Inconclusive data from mammography, ultrasound and standard morphological MR series (T1,T2, FAT SAT) in the estimation of changes after augmentation and oncoplastic surgery require the use of multiparametric MRI analysis as a supplementary method for increasing sensitivity and specificity of breast MRI

  20. Tubular Carcinoma of the Breast: Advantages and Limitations of Breast Tomosynthesis

    Directory of Open Access Journals (Sweden)

    Filipa Vilaverde

    2016-01-01

    Full Text Available Tubular carcinoma of the breast is a rare variant of invasive ductal carcinoma. We report a case of 42-year-old asymptomatic female with a histopathological proven multifocal tubular carcinoma, studied by mammography, Tomosynthesis, Ultrasound, and Magnetic Resonance. Herein, we discuss the advantages and limitations of Tomosynthesis, an emerging imaging technique, in this particular case.

  1. Tubular Carcinoma of the Breast: Advantages and Limitations of Breast Tomosynthesis

    Science.gov (United States)

    Rocha, Ana; Reis, Alcinda

    2016-01-01

    Tubular carcinoma of the breast is a rare variant of invasive ductal carcinoma. We report a case of 42-year-old asymptomatic female with a histopathological proven multifocal tubular carcinoma, studied by mammography, Tomosynthesis, Ultrasound, and Magnetic Resonance. Herein, we discuss the advantages and limitations of Tomosynthesis, an emerging imaging technique, in this particular case. PMID:28116205

  2. Breast abscess as a complication of human brucellosis.

    Science.gov (United States)

    Gurleyik, Emin

    2006-01-01

    Breast abscess caused by human brucellosis is extremely rare. A 46-year-old woman received the diagnosis of brucellosis with positive serologic tests. Two weeks after the onset of symptoms, the case was complicated by vertebral (L5-S1) abscess which was treated by surgical drainage. One month after the diagnosis of brucellosis, the patient noticed a mass in her left breast. Breast palpation revealed a painless, mobile, round mass that was hypoechoic on ultrasound imaging. Purulent material was obtained by needle aspiration. Besides treatment of the breast abscess by needle aspiration, brucellosis was successfully controlled by prolonged antimicrobial treatment.

  3. A review of biomechanically informed breast image registration

    International Nuclear Information System (INIS)

    Hipwell, John H; Vavourakis, Vasileios; Mertzanidou, Thomy; Eiben, Björn; Hawkes, David J; Han, Lianghao

    2016-01-01

    Breast radiology encompasses the full range of imaging modalities from routine imaging via x-ray mammography, magnetic resonance imaging and ultrasound (both two- and three-dimensional), to more recent technologies such as digital breast tomosynthesis, and dedicated breast imaging systems for positron emission mammography and ultrasound tomography. In addition new and experimental modalities, such as Photoacoustics, Near Infrared Spectroscopy and Electrical Impedance Tomography etc, are emerging. The breast is a highly deformable structure however, and this greatly complicates visual comparison of imaging modalities for the purposes of breast screening, cancer diagnosis (including image guided biopsy), tumour staging, treatment monitoring, surgical planning and simulation of the effects of surgery and wound healing etc. Due primarily to the challenges posed by these gross, non-rigid deformations, development of automated methods which enable registration, and hence fusion, of information within and across breast imaging modalities, and between the images and the physical space of the breast during interventions, remains an active research field which has yet to translate suitable methods into clinical practice. This review describes current research in the field of breast biomechanical modelling and identifies relevant publications where the resulting models have been incorporated into breast image registration and simulation algorithms. Despite these developments there remain a number of issues that limit clinical application of biomechanical modelling. These include the accuracy of constitutive modelling, implementation of representative boundary conditions, failure to meet clinically acceptable levels of computational cost, challenges associated with automating patient-specific model generation (i.e. robust image segmentation and mesh generation) and the complexity of applying biomechanical modelling methods in routine clinical practice. (topical review)

  4. Training a new generation of breast surgeons: are we succeeding?

    Science.gov (United States)

    Sclafani, Lisa M; Bleznak, Aaron; Kelly, Tricia; El-Tamer, Mahmoud B

    2012-06-01

    Society of Surgical Oncology (SSO)-approved fellowships in Breast Oncology began training fellows in 2004. Here we ascertain methods of evaluating and improving the fellowship experience through fellowship alumni experience. We conducted an electronic survey of fellowship graduates to learn perceived successes and weaknesses of their fellowship training, as well as their current practice experiences. Our electronic survey focused on their preparedness for practice, their job opportunities, and their use of image-guided biopsies in practice. Between 2005 and 2009, 142 fellows graduated and received our survey; 85 (60%) responded. Although 98% of graduates though that they were well prepared by their fellowship for performing breast cancer surgery, fewer thought that they were well prepared to perform oncoplastic techniques (53%), ultrasound (39%), and ultrasound-guided biopsies (28%). Nevertheless, many acquired additional training, and 63% were performing ultrasound-guided biopsies in practice. The majority (76%) were performing breast surgery exclusively, with 14% identifying themselves as director of a breast center and only 29% describing themselves as being in private practice-the rest being employed at a hospital or university. Only 8% of respondents were disappointed with the job market, and 67% stated they had received at least three job offers; 82% were satisfied in their current job. SSO breast oncology fellowships appear to be training confident, well-prepared graduates with good job outlooks, and many are achieving leadership positions. Deficiencies in sonography training, some advanced surgical techniques, and administrative experiences should be addressed by program directors as graduates do perceive the need for such training.

  5. Predictive values of Bi-Rads categories 3, 4 and 5 in non-palpable breast masses evaluated by mammography, ultrasound and magnetic resonance imaging; Valores preditivos das categorias 3, 4 e 5 do sistema Bi-Rads em lesoes mamarias nodulares nao-palpaveis avaliadas por mamografia, ultra-sonografia e ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Roveda Junior, Decio; Fleury, Eduardo de Castro Faria [Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Faculdade de Ciencias Medicas. Servico de Diagnostico por Imagem]. E-mail: decio.jr@uol.com.br; Piato, Sebastiao [Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Dept. de Obstetricia e Ginecologia. Clinica Ginecologica; Oliveira, Vilmar Marques de [Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Dept. de Obstetricia e Ginecologia. Ginecologia Geral; Rinaldi, Jose Francisco [Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Dept. de Obstetricia e Ginecologia. Clinica de Mastologia; Ferreira, Carlos Alberto Pecci [Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Faculdade de Ciencias Medicas. Dept. de Clinica Medica. Servico de Imagenologia Mamaria

    2007-03-15

    Objective: To evaluate the predictive value of BI-RADS{sup TM} categories 3, 4 and 5 in non-palpable breast masses assessed by mammography, ultrasound and magnetic resonance imaging. Materials And Methods: Twenty-nine patients with BI-RADS categories 3, 4 and 5 non-palpable breast masses identified by mammograms were submitted to complementary ultrasound and magnetic resonance imaging studies, besides excisional biopsy. In total, 30 biopsies were performed. The lesions as well as their respective BI-RADS classification into 3, 4 and 5 were correlated with the histopathological results. The predictive values calculation was made by means of specific mathematical equations. Results: Negative predictive values for category 3 were: mammography, 69.23%; ultrasound, 70.58%; and magnetic resonance imaging, 100%. Positive predictive values for category 4 were: mammography, 63.63%; ultrasound, 50%; and magnetic resonance imaging, 30.76%. For category 5, positive predictive values were: mammography and ultrasound, 100%; and magnetic resonance imaging, 92.85%. Conclusion: For category 3, the negative predictive value of magnetic resonance imaging was high, and for categories 4 and 5, the positive predictive values of the three modalities were moderate. (author)

  6. Ultrasound-assisted extraction technique for establishing selenium contents in breast cancer biopsies by Zeeman-electrothermal atomic absorption spectrometry using multi-injection

    International Nuclear Information System (INIS)

    Lavilla, I.; Mosquera, A.; Millos, J.; Cameselle, J.; Bendicho, C.

    2006-01-01

    A solid-liquid extraction method is developed to establish the contents of selenium in breast cancer biopsies. The method is based on the ultrasound-assisted extraction of selenium from pretreated biopsies prior to Se determination by atomic absorption spectrometry with longitudinal-Zeeman background correction. Fifty-one breast biopsies were collected from the Cies Hospital (Vigo, Spain), 32 of which correspond to tumor tissue and 19 to normal tissue (parenchyma). Difficulties arising from the samples analyzed, i.e. small samples mass (50-100 mg), extremely low Se contents and sample texture modification including tissue hardening due to formaldehyde preservation are addressed and overcome. High intensity sonication using a probe together with addition of hydrogen peroxide succeeded in completely extracting Se from biopsies. The multiple injection technique was useful to tackle the low Se contents present in some biopsies. The detection limit was 25 ng g -1 of Se and the precision, expressed as relative standard deviation, was less than 10%. Se contents ranged from 0.08 to 0.4 μg g -1 for parenchyma samples and from 0.09 to 0.8 μg g -1 for tumor samples. In general, Se levels in tumor biopsies were higher as compared with the adjacent normal tissue in 19 patients by a factor of up to 6. Analytical data confirmed Se accumulation in the breast tumors

  7. Total folate and unmetabolized folic acid in the breast milk of a cross-section of Canadian women.

    Science.gov (United States)

    Page, Rachael; Robichaud, André; Arbuckle, Tye E; Fraser, William D; MacFarlane, Amanda J

    2017-05-01

    Background: Folate requirements increase during pregnancy and lactation. It is recommended that women who could become pregnant, are pregnant, or are lactating consume a folic acid (FA)-containing supplement. Objectives: We sought to determine breast-milk total folate and unmetabolized folic acid (UMFA) contents and their relation with FA-supplement use and doses in a cohort of Canadian mothers who were enrolled in the MIREC (Maternal-Infant Research on Environmental Chemicals) study. Design: Breast-milk tetrahydrofolate (THF), 5-methyl-THF, 5-formyl-THF, 5,10-methenyl-THF, and UMFA were measured with the use of liquid chromatography-tandem mass spectrometry ( n = 561). Total daily supplemental FA intake was based on self-reported FA-supplement use. Results: UMFA was detectable in the milk of 96.1% of the women. Total daily FA intake from supplements was associated with breast folate concentration and species. Breast-milk total folate was 18% higher ( P 400 μg FA/d ( P ≤ 0.004). 5-Methyl-THF was 19% lower ( P 400 μg FA/d had proportionally lower 5-methyl-THF and higher UMFA than did women who consumed ≤400 μg FA/d. Conclusions: FA-supplement use was associated with modestly higher breast-milk total folate. Detectable breast-milk UMFA was nearly ubiquitous, including in women who did not consume an FA supplement. Breast-milk UMFA was proportionally higher than 5-methyl-THF in women who consumed >400 μg FA/d, thereby suggesting that higher doses exceed the physiologic capacity to metabolize FA and result in the preferential uptake of FA in breast milk. Therefore, FA-supplement doses >400 μg may not be warranted, especially in populations for whom FA fortification is mandatory. © 2017 American Society for Nutrition.

  8. Vitamin C and survival among women with breast cancer: a meta-analysis.

    Science.gov (United States)

    Harris, Holly R; Orsini, Nicola; Wolk, Alicja

    2014-05-01

    The association between dietary vitamin C intake and breast cancer survival is inconsistent and few studies have specifically examined vitamin C supplement use among women with breast cancer. The purpose of this study was to summarise results from prospective studies on the association between vitamin C supplement use and dietary vitamin C intake and breast cancer-specific mortality and total mortality. Studies were identified using the PubMed database through February 6, 2014 and by examining the references of retrieved articles. Prospective studies were included if they reported relative risks (RR) with 95% confidence intervals (95% CIs) for at least two categories or as a continuous exposure. Random-effects models were used to combine study-specific results. The ten identified studies examined vitamin C supplement use (n=6) and dietary vitamin C intake (n=7) and included 17,696 breast cancer cases, 2791 total deaths, and 1558 breast cancer-specific deaths. The summary RR (95% CI) for post-diagnosis vitamin C supplement use was 0.81 (95% CI 0.72-0.91) for total mortality and 0.85 (95% CI 0.74-0.99) for breast cancer-specific mortality. The summary RR for a 100mg per day increase in dietary vitamin C intake was 0.73 (95% CI 0.59-0.89) for total mortality and 0.78 (95% CI 0.64-0.94) for breast cancer-specific mortality. Results from this meta-analysis suggest that post-diagnosis vitamin C supplement use may be associated with a reduced risk of mortality. Dietary vitamin C intake was also statistically significantly associated with a reduced risk of total mortality and breast cancer-specific mortality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. ACR Appropriateness Criteria® Breast Cancer Screening.

    Science.gov (United States)

    Mainiero, Martha B; Moy, Linda; Baron, Paul; Didwania, Aarati D; diFlorio, Roberta M; Green, Edward D; Heller, Samantha L; Holbrook, Anna I; Lee, Su-Ju; Lewin, Alana A; Lourenco, Ana P; Nance, Kara J; Niell, Bethany L; Slanetz, Priscilla J; Stuckey, Ashley R; Vincoff, Nina S; Weinstein, Susan P; Yepes, Monica M; Newell, Mary S

    2017-11-01

    Breast cancer screening recommendations are based on risk factors. For average-risk women, screening mammography and/or digital breast tomosynthesis is recommended beginning at age 40. Ultrasound (US) may be useful as an adjunct to mammography for incremental cancer detection in women with dense breasts, but the balance between increased cancer detection and the increased risk of a false-positive examination should be considered in the decision. For intermediate-risk women, US or MRI may be indicated as an adjunct to mammography depending upon specific risk factors. For women at high risk due to prior mantle radiation between the ages of 10 to 30, mammography is recommended starting 8 years after radiation therapy but not before age 25. For women with a genetic predisposition, annual screening mammography is recommended beginning 10 years earlier than the affected relative at the time of diagnosis but not before age 30. Annual screening MRI is recommended in high-risk women as an adjunct to mammography. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Development of a fresh cadaver model for instruction of ultrasound-guided breast biopsy during the surgery clerkship: pre-test and post-test results among third-year medical students.

    Science.gov (United States)

    McCrary, Hilary C; Krate, Jonida; Savilo, Christine E; Tran, Melissa H; Ho, Hang T; Adamas-Rappaport, William J; Viscusi, Rebecca K

    2016-11-01

    The aim of our study was to determine if a fresh cadaver model is a viable method for teaching ultrasound (US)-guided breast biopsy of palpable breast lesions. Third-year medical students were assessed both preinstruction and postinstruction on their ability to perform US-guided needle aspiration or biopsy of artificially created masses using a 10-item checklist. Forty-one third-year medical students completed the cadaver laboratory as part of the surgery clerkship. Eight items on the checklist were found to be significantly different between pre-testing and post-testing. The mean preinstruction score was 2.4, whereas the mean postinstruction score was 7.10 (P cadaver models have been widely used in medical education. However, there are few fresh cadaver models that provide instruction on procedures done in the outpatient setting. Our model was found to be an effective method for the instruction of US-guided breast biopsy among medical students. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Sonographic features of invasive ductal breast carcinomas predictive of malignancy grade

    Directory of Open Access Journals (Sweden)

    Kanika Gupta

    2018-01-01

    Full Text Available Context: Assessment of individual sonographic features provides vital clues about the biological behavior of breast masses and can assist in determining histological grade of malignancy and thereby prognosis. Aims: Assessment of individual sonographic features of biopsy proven invasive ductal breast carcinomas as predictors of malignancy grade. Settings and Design: A retrospective analysis of sonographic findings of 103 biopsy proven invasive ductal breast carcinomas. Materials and Methods: Tumor characteristics on gray-scale ultrasound and color flow were assessed using American College of Radiology (ACR Breast Imaging Reporting and Data System (BI-RADS Atlas Fifth Edition. The sonographic findings of masses were individually correlated with their histopathologic grades. Statistical Analysis Used: Chi square test, ordinal regression, and Goodman and Kruskal tau test. Results: Breast mass showing reversal/lack of diastolic flow has a high probability of belonging to histological high grade tumor ( β 1.566, P 0.0001. The masses with abrupt interface boundary are more likely grade 3 ( β 1.524, P 0.001 in comparison to masses with echogenic halos. The suspicious calcifications present in and outside the mass is a finding associated with histologically high grade tumors. The invasive ductal carcinomas (IDCs with complex solid and cystic echotexture are more likely to be of high histological grade ( β 1.146, P 0.04 as compared to masses with hypoechoic echotexture. Conclusions: Certain ultrasound features are associated with tumor grade on histopathology. If the radiologist is cognizant of these sonographic features, ultrasound can be a potent modality for predicting histopathological grade of IDCs of the breast, especially in settings where advanced tests such as receptor and molecular analyses are limited.

  12. Ultrasound-mediated microbubble enhancement of radiation therapy studied using three-dimensional high-frequency power Doppler ultrasound.

    Science.gov (United States)

    Kwok, Sheldon J J; El Kaffas, Ahmed; Lai, Priscilla; Al Mahrouki, Azza; Lee, Justin; Iradji, Sara; Tran, William Tyler; Giles, Anoja; Czarnota, Gregory J

    2013-11-01

    Tumor responses to high-dose (>8 Gy) radiation therapy are tightly connected to endothelial cell death. In the study described here, we investigated whether ultrasound-activated microbubbles can locally enhance tumor response to radiation treatments of 2 and 8 Gy by mechanically perturbing the endothelial lining of tumors. We evaluated vascular changes resulting from combined microbubble and radiation treatments using high-frequency 3-D power Doppler ultrasound in a breast cancer xenograft model. We compared treatment effects and monitored vasculature damage 3 hours, 24 hours and 7 days after treatment delivery. Mice treated with 2 Gy radiation and ultrasound-activated microbubbles exhibited a decrease in vascular index to 48 ± 10% at 24 hours, whereas vascular indices of mice treated with 2 Gy radiation alone or microbubbles alone were relatively unchanged at 95 ± 14% and 78 ± 14%, respectively. These results suggest that ultrasound-activated microbubbles enhance the effects of 2 Gy radiation through a synergistic mechanism, resulting in alterations of tumor blood flow. This novel therapy may potentiate lower radiation doses to preferentially target endothelial cells, thus reducing effects on neighboring normal tissue and increasing the efficacy of cancer treatments. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  13. Effect of Agaricus sylvaticus supplementation on nutritional status and adverse events of chemotherapy of breast cancer: a randomized, placebo-controlled, double-blind clinical trial.

    Science.gov (United States)

    Valadares, Fabiana; Garbi Novaes, Maria Rita Carvalho; Cañete, Roberto

    2013-01-01

    Breast cancer (BC) represents the highest incidence of malignancy in women throughout the world. Medicinal fungi can stimulate the body, reduce side-effects associated with chemotherapy and improve the quality of life in patients with cancer. To evaluate the effects of dietary supplementation of Agaricus sylvaticus on clinical and nutritional parameters in BC patients undergoing chemotherapy. A randomized, placebo-controlled, double-blind, clinical trial was carried out at the Oncology Clinic, Hospital of the Federal District-Brazil from September 2007 to July 2009. Forty six patients with BC, Stage II and III, were randomly assigned to receive either nutritional supplement with A. sylvaticus (2.1 g/day) or placebo. Patients were evaluated during treatment period. Patient supplemented with A. sylvaticus improved in clinical parameters and gastrointestinal functions. Poor appetite decreased by 20% with no changes in bowel functions (92.8%), nausea and vomiting (80%). Dietary supplementation with A. sylvaticus improved nutritional status and reduced abnormal bowel functions, nausea, vomiting, and anorexia in patients with BC receiving chemotherapy.

  14. The current status of imaging diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Liu Fang; Tang Guangcai

    2013-01-01

    In recent years, the incidence and the mortality rate of female breast cancer in our country is increasing, Early diagnosis of breast cancer is particularly important. Precious preoperative staging in the breast cancer is advantageous for the treatment planning. Evaluating the efficacy of chemotherapy is beneficial for adjusting the follow-up plan. Imaging examination has become an important role in breast cancer management. At present, commonly used equipment include mammography, ultrasound, CT, and MRI, etc. This article reviews the present study status of these tools in diagnosis of breast cancer. A reasonable and effective choice of those tools can facilitate clinic diagnosis and treatment. (authors)

  15. The Impact of Axillary Lymph Node Surgery on Breast Skin Thickening During and After Radiation Therapy for Breast Cancer

    International Nuclear Information System (INIS)

    Torres, Mylin A.; Yang, Xiaofeng; Noreen, Samantha; Chen, Hao; Han, Tatiana; Henry, Simone; Mister, Donna; Andic, Fundagal; Long, Qi; Liu, Tian

    2016-01-01

    Purpose: This prospective study was conducted to determine predictors of epidermal thickening during and after whole-breast radiation therapy (XRT) using objective measurements acquired with ultrasound. Methods and Materials: After breast-conserving surgery, 70 women received a definitive course of whole-breast XRT (50 Gy plus boost). Prior to XRT, at week 6 of XRT, and 6 weeks after XRT, patients underwent objective ultrasound measurements of epidermal thickness over the lumpectomy cavity and all 4 quadrants of the treated breast. A skin thickness ratio (STRA) was then generated normalizing for corresponding measurements taken of the untreated breast. Results: Baseline measurements indicated that 87% of patients had skin thickening in the treated versus untreated breast (mean increase, 27%; SD, 0.29) prior to XRT. The STRA increased significantly by week 6 of XRT (mean, 25%; SD, 0.46) and continued to increase significantly 6 weeks after XRT (mean, 33%; SD, 0.46) above baseline measurements (P<.001 for both time points). On multivariate analysis, breast volume (P=.003) and surgical evaluation of the axilla with full lymph node dissection (P<.05) predicted for more severe changes in the STRA 6 weeks after XRT compared with baseline. STRA measurements correlated with physician ratings of skin toxicity according to Radiation Therapy Oncology Group grading criteria. Conclusions: This is one of the first studies to objectively document that lymph node surgery affects XRT-induced skin thickening in patients with breast cancer. Surgical evaluation of the axilla with complete lymph node dissection was associated with the most severe XRT-induced skin changes after XRT completion. These results may inform future studies aimed at minimizing side effects of XRT and surgery, particularly when surgical lymph node assessments may not alter breast cancer management or outcome.

  16. The Impact of Axillary Lymph Node Surgery on Breast Skin Thickening During and After Radiation Therapy for Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Mylin A., E-mail: matorre@emory.edu [Department of Radiation Oncology, Emory University School of Medicine, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Yang, Xiaofeng [Department of Radiation Oncology, Emory University School of Medicine, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Noreen, Samantha [Department of Biostatistics and Bioinformatics, Rollins School of Public Health, Emory University, Atlanta, Georgia (United States); Chen, Hao [Department of Radiation Oncology, Emory University School of Medicine, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Provision Center for Proton Therapy, Knoxville, Tennessee (United States); Han, Tatiana; Henry, Simone; Mister, Donna [Department of Radiation Oncology, Emory University School of Medicine, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Andic, Fundagal [Department of Radiation Oncology, Cukurova University School of Medicine, Adana (Turkey); Long, Qi [Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Department of Biostatistics and Bioinformatics, Rollins School of Public Health, Emory University, Atlanta, Georgia (United States); Liu, Tian [Department of Radiation Oncology, Emory University School of Medicine, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States)

    2016-06-01

    Purpose: This prospective study was conducted to determine predictors of epidermal thickening during and after whole-breast radiation therapy (XRT) using objective measurements acquired with ultrasound. Methods and Materials: After breast-conserving surgery, 70 women received a definitive course of whole-breast XRT (50 Gy plus boost). Prior to XRT, at week 6 of XRT, and 6 weeks after XRT, patients underwent objective ultrasound measurements of epidermal thickness over the lumpectomy cavity and all 4 quadrants of the treated breast. A skin thickness ratio (STRA) was then generated normalizing for corresponding measurements taken of the untreated breast. Results: Baseline measurements indicated that 87% of patients had skin thickening in the treated versus untreated breast (mean increase, 27%; SD, 0.29) prior to XRT. The STRA increased significantly by week 6 of XRT (mean, 25%; SD, 0.46) and continued to increase significantly 6 weeks after XRT (mean, 33%; SD, 0.46) above baseline measurements (P<.001 for both time points). On multivariate analysis, breast volume (P=.003) and surgical evaluation of the axilla with full lymph node dissection (P<.05) predicted for more severe changes in the STRA 6 weeks after XRT compared with baseline. STRA measurements correlated with physician ratings of skin toxicity according to Radiation Therapy Oncology Group grading criteria. Conclusions: This is one of the first studies to objectively document that lymph node surgery affects XRT-induced skin thickening in patients with breast cancer. Surgical evaluation of the axilla with complete lymph node dissection was associated with the most severe XRT-induced skin changes after XRT completion. These results may inform future studies aimed at minimizing side effects of XRT and surgery, particularly when surgical lymph node assessments may not alter breast cancer management or outcome.

  17. Ultrasound findings and histological features of ductal carcinoma in situ detected by ultrasound examination alone

    OpenAIRE

    Izumori, Ayumi; Takebe, Koji; Sato, Akira

    2009-01-01

    Background With the increasing use of high-resolution ultrasound (US) examination, many breast carcinomas that cannot be identified by mammography (MMG) alone have been detected. Many of these carcinomas are ductal carcinoma in situ (DCIS) and small-sized invasive carcinomas. Until date, DCISs have often been described as palpable masses with calcifications on MMG, but what are the characteristics of DCISs that are detectable by US alone? Methods One hundred fifty cases with DCIS that we expe...

  18. Effect of micellized natural (D-α-tocopherol) vs. synthetic (DL-α-tocopheryl acetate) vitamin E supplementation given to turkeys on oxidative status and breast meat quality characteristics.

    Science.gov (United States)

    Rey, A I; Segura, J; Olivares, A; Cerisuelo, A; Piñeiro, C; López-Bote, C J

    2015-06-01

    This study evaluates the effect of vitamin E supplementation source (micellized natural vs. the synthetic form) and dosage (40, 80, or 120 mg/kg) on α-tocopherol concentration in plasma and muscle, antioxidant capacity, and breast meat quality in turkeys. Three hundred female turkeys were randomly selected at an average live weight 63.2 g±0.5 and distributed into 7 groups. One group (control) was fed a standard diet without vitamin E supplementation and the other 6 were given mixed diets supplemented with the natural (d-α-tocopherol) or synthetic (dl-α-tocopheryl acetate) form of vitamin E in 3 dosages (40, 80, or 120 mg/kg). Following 11 wk feeding, results showed that performance parameters were not modified either by source or dosage of vitamin E supplementation to the turkeys. Plasma and muscle α-tocopherol at d 9 of refrigerated storage were higher when turkeys were supplemented with the natural form at higher doses. Losses in the concentration of α-tocopherol in meat between the beginning and the end of the 9 d refrigerated storage were greater in the groups supplemented with the synthetic form of vitamin E compared to those receiving the natural supplementation. The relationship between plasma α-tocopherol and the Trolox equivalent antioxidant capacity followed a different trend depending on the vitamin E source. Intramuscular fat was not significantly affected by the vitamin E source supplementation; however the slope of the linear regression equation was lower for the natural form than for the synthetic form. Turkeys given the natural form had higher C18:1n-9 but lower C15:1, C17:1, C20:5n-3, and C22:6n-3 in breast muscle. Meat samples from turkeys supplemented with natural vitamin E had higher deoxymyoglobin at d 3, 6, and 9 and lower metmyoglobin at d 9 of refrigerated storage than those receiving the synthetic form. Dietary supplementation with medium doses (80 mg/kg) micellized d-α-tocopherol is an interesting feeding strategy for

  19. Antioxidants and breast cancer risk- a population-based case-control study in Canada

    Directory of Open Access Journals (Sweden)

    Morrison Howard

    2011-08-01

    Full Text Available Abstract Background The effect of antioxidants on breast cancer is still controversial. Our objective was to assess the association between antioxidants and breast cancer risk in a large population-based case-control study. Methods The study population included 2,362 cases with pathologically confirmed incident breast cancer (866 premenopausal and 1,496 postmenopausal and 2,462 controls in Canada. Intakes of antioxidants from diet and from supplementation as well as other potential risk factors for breast cancer were collected by a self-reported questionnaire. Results Compared with subjects with no supplementation, 10 years or longer supplementation of zinc had multivariable-adjusted odds ratios (OR and 95% confidence intervals (CI of 0.46 (0.25-0.85 for premenopausal women, while supplementation of 10 years or longer of multiple vitamin, beta-carotene, vitamin C, vitamin E and zinc had multivariable-adjusted ORs (95% CIs of 0.74 (0.59, 0.92, 0.58 (0.36, 0.95, 0.79 (0.63-0.99, 0.75 (0.58, 0.97, and 0.47 (0.28-0.78, respectively, for postmenopausal women. No significant effect of antioxidants from dietary sources (including beta-carotene, alpha-carotene, lycopene, lutein and zeaxanthin, vitamin C, vitamin E, selenium and zinc or from supplementation less than 10 years was observed. Conclusions This study suggests that supplementation of zinc in premenopausal women, and supplementation of multiple vitamin, beta-carotene, vitamin C, vitamin E and zinc in postmenopausal women for 10 or more years may protect women from developing breast cancer. However, we were unable to determine the overall effect of total dose or intake from both diet and supplement.

  20. Radiological assessment of the breast following enhancement with Macrolane: Managing the challenges

    Energy Technology Data Exchange (ETDEWEB)

    Scaperrotta, Gianfranco, E-mail: gianfranco.scaperrotta@istitutotumori.mi.it [Fondazione IRCCS Istituto Nazionale dei Tumori, Via Venezian 1, 20133 Milan (Italy); Satchithananda, Keshtra, E-mail: keshthra.satchi@virgin.net [Imaging Department, King’s College Hospital NHS Foundation Trust and King’s College, Second Floor, Denmark Wing, Denmark Hill, London SE5 9RS (United Kingdom); Tengvar, Magnus, E-mail: magnus.tengvar@karolinska.se [Radiology Department, Karolinska University Hospital, Karolinska Vägen, 171 76 Solna (Sweden); Post, Karin, E-mail: karin.post@t-online.de [Radiologie Nuklearmedizin, Diakonissen KH, Speyerer Straße 91, 68163 Mannheim (Germany); Lim, Adrian K. [Imaging Department, Imperial College Healthcare NHS Trust, Charing Cross Hospital, Fulham Palace Road, London W6 8RF (United Kingdom); Panizza, Pietro, E-mail: ppanizza@sirm.org [Radiology Department, San Raffaele Hospital, Via Olgettina 60, 20132 Milan (Italy); Wesolowska, Ewa, E-mail: ewawu7@wp.pl [The M. Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, 02-034 Warsaw, ul. Wawelska 15B (Poland); Inglefield, Christopher J., E-mail: chris@lbps.co.uk [London Bridge Plastic Surgery and Aesthetic Clinic, 54 Wimpole Street, London W1G 8YJ (United Kingdom)

    2017-01-15

    Highlights: • Macrolane VRF{sup ®}, a biodegradable, stabilized hyaluronic acid gel, was used for breast enhancement 2008–2012. • Even after more than 4 years, small amounts of Macrolane can still be visible on magnetic resonance imaging (MRI) or ultrasound in some patients similar to permanent implants, the presence of Macrolane gel may interfere with interpretation of mammography. • Knowledge of the product’s appearance on radiological assessment of breasts following Macrolane treatment is therefore required. • It is possible to assess the vast majority of patients using a combination of digital mammography and ultrasonography examination. - Abstract: Macrolane VRF{sup ®}, a biodegradable, stabilized hyaluronic acid gel, was used for breast enhancement 2008–2012. Similar to permanent implants, the presence of Macrolane gel may interfere with interpretation of mammography. This short communication aims to provide a guide to the appearance of Macrolane on radiology examination (including mammography, ultrasound and magnetic resonance imaging) and aid selection of the most appropriate imaging modality to facilitate breast examination in women who have undergone Macrolane breast enhancement.

  1. Radiological assessment of the breast following enhancement with Macrolane: Managing the challenges

    International Nuclear Information System (INIS)

    Scaperrotta, Gianfranco; Satchithananda, Keshtra; Tengvar, Magnus; Post, Karin; Lim, Adrian K.; Panizza, Pietro; Wesolowska, Ewa; Inglefield, Christopher J.

    2017-01-01

    Highlights: • Macrolane VRF ® , a biodegradable, stabilized hyaluronic acid gel, was used for breast enhancement 2008–2012. • Even after more than 4 years, small amounts of Macrolane can still be visible on magnetic resonance imaging (MRI) or ultrasound in some patients similar to permanent implants, the presence of Macrolane gel may interfere with interpretation of mammography. • Knowledge of the product’s appearance on radiological assessment of breasts following Macrolane treatment is therefore required. • It is possible to assess the vast majority of patients using a combination of digital mammography and ultrasonography examination. - Abstract: Macrolane VRF ® , a biodegradable, stabilized hyaluronic acid gel, was used for breast enhancement 2008–2012. Similar to permanent implants, the presence of Macrolane gel may interfere with interpretation of mammography. This short communication aims to provide a guide to the appearance of Macrolane on radiology examination (including mammography, ultrasound and magnetic resonance imaging) and aid selection of the most appropriate imaging modality to facilitate breast examination in women who have undergone Macrolane breast enhancement.

  2. Anaplastic large cell lymphoma associated with breast implants

    Directory of Open Access Journals (Sweden)

    Vid Bajuk

    2017-02-01

    Full Text Available An increasing number of women worldwide decide for esthetic correction of breasts with silicone implants and post-cancer breast reconstruction with tissue expanders and silicone breast implants. It is estimated that more than 10 million women around the globe have them. Tere are approximately 200 known cases of patients with anaplastic large cell lymphoma (ALCL linked with silicone breast implants reported in medical literature. ALCL is a rare disease with an annual incidence of 0.1–0.3/100 000 women with breast silicone implants. In the presence of clinical signs, physician should also consider this rare form of ALCL in differential diagnosis. Patients are on average 50 years old. Long afer implantation surgery, the patient may experience breast swelling, pain and/or asymmetry. In diagnostics, ultrasound and cytological examination are required. During ultrasound examination fluid formation (seroma or solid tumor mass can be detected. Treatment is individualized. Due to tumor nature, implant resection and total capsulectomy are usually indicated; also, chemo- and radiotherapy might rarely be required. Five-year survival rate depends on tumor form and correlates well with clinical fndings of seroma or solid mass. In the more frequent form, seroma, fve-year survival rate is 100 %, while in the case of solid tumor mass fve-year survival rate is 75 %. The rarity of this disease makes it difficult to diagnose, but nevertheless, early detection and treatment are important for better recovery.

  3. [Focused ultrasound therapy: current status and potential applications in neurosurgery].

    Science.gov (United States)

    Dervishi, E; Aubry, J-F; Delattre, J-Y; Boch, A-L

    2013-12-01

    High Intensity Focused Ultrasound (HIFU) therapy is an innovative approach for tissue ablation, based on high intensity focused ultrasound beams. At the focus, HIFU induces a temperature elevation and the tissue can be thermally destroyed. In fact, this approach has been tested in a number of clinical studies for the treatment of several tumors, primarily the prostate, uterine, breast, bone, liver, kidney and pancreas. For transcranial brain therapy, the skull bone is a major limitation, however, new adaptive techniques of phase correction for focusing ultrasound through the skull have recently been implemented by research systems, paving the way for HIFU therapy to become an interesting alternative to brain surgery and radiotherapy. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  4. Breast abscess: evidence based management recommendations.

    Science.gov (United States)

    Lam, Elaine; Chan, Tiffany; Wiseman, Sam M

    2014-07-01

    Literature review was carried out and studies reporting on treatment of breast abscesses were critically appraised for quality and their level of evidence using the Strength of Recommendation Taxonomy guidelines, and key recommendations were summarized. Needle aspiration either with or without ultrasound guidance should be employed as first line treatment of breast abscesses. This approach has the potential benefits of: superior cosmesis, shorter healing time, and avoidance of general anaesthesia. Multiple aspiration sessions may be required for cure. Ultrasound-guided percutaneous catheter placement may be considered as an alternative approach for treatment of larger abscesses (>3 cm). Surgical incision and drainage should be considered for first line therapy in large (>5 cm), multiloculated, or long standing abscesses, or if percutaneous drainage is unsuccessful. All patients should be treated concurrently with antibiotics. Patients with recurrent subareolar abscesses and fistulas should be referred for consideration of surgical treatment.

  5. Initial experience of automated breast volume scanning (ABVS) and ultrasound elastography in predicting breast cancer subtypes and staging.

    Science.gov (United States)

    Wang, Xiao-Lei; Tao, Lin; Zhou, Xian-Li; Wei, Hong; Sun, Jia-Wei

    2016-12-01

    Breast cancer is a heterogeneous disease consisting of distinct histopathological subtypes with different clinical outcomes. In this article, we identified the automated breast volume scanning (ABVS) and shear wave velocity (SWV) characteristics of different pathological types of breast carcinoma. A retrospective review of both ABVS and SWV imaging of 118 consecutive breast masses was performed. The imaging features of both techniques were assessed with reference to histopathological results. Echo heterogeneity with a smooth and lobulated margin was a significant feature more frequently found in mucinous carcinoma groups (100%, P breast carcinoma stages. The central and tumor margin areas of ductal carcinomas were much harder than in tubular carcinoma and micro-carcinoma, respectively (P breast carcinoma types and stages, ABVS and SWV imaging has the potential to give clues about breast carcinoma differentiation in a non-invasive manner. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. The utility of ultrasound superb microvascular imaging for evaluation of breast tumour vascularity: comparison with colour and power Doppler imaging regarding diagnostic performance.

    Science.gov (United States)

    Park, A Y; Seo, B K; Woo, O H; Jung, K S; Cho, K R; Park, E K; Cha, S H; Cha, J

    2018-03-01

    To investigate the utility of superb microvascular imaging (SMI) for evaluating the vascularity of breast masses in comparison with colour or power Doppler ultrasound (US) and the effect on diagnostic performance. A total of 191 biopsy-proven masses (99 benign and 92 malignant) in 166 women with greyscale, colour Doppler, power Doppler, and SMI images were enrolled in this retrospective study. Three radiologists analysed the vascular images using a three-factor scoring system to evaluate the number, morphology, and distribution of tumour vessels. They assessed the Breast Imaging-Reporting and Data System categories for greyscale US alone and combinations of greyscale US and each type of vascular US. The Kruskal-Wallis test was performed and the area under the receiver-operating characteristic curve (AUC) measured. On SMI, vascular scores were compared between benign and malignant masses and the optimal cut-off value for the overall score was determined. SMI showed higher vascular scores than colour or power Doppler US and malignant masses had higher scores than benign masses (ppower Doppler US (AUC, 0.815 versus 0.774, 0.789, 0.791; ppower Doppler US for characterising the vascularity in breast masses and improving diagnostic performance. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. Does the degree of background enhancement in breast MRI affect the detection and staging of breast cancer?

    International Nuclear Information System (INIS)

    Uematsu, Takayoshi; Kasami, Masako; Watanabe, Junichiro

    2011-01-01

    The purpose of this study was to assess the influence of background enhancement on the detection and staging of breast cancer using MRI as an adjunct to mammography or ultrasound. One hundred forty-six bilateral breast MRI examinations were evaluated to assess the extent of a known primary tumour and to problem solve after mammography or ultrasound without adjusting for the phase in the patients' menstrual cycle. The background enhancement was classified into four categories by visual evaluation: minimal, mild, moderate and marked. In total, 131 histologically confirmed abnormal cases (104 malignant and 27 benign) and 15 normal cases were included in the analysis. There was no tumour size-related bias between the groups (p = 0.522). For the primary index tumour, the sensitivities of MRI with minimal/mild and moderate/marked background enhancement were 100% and 76% (p = 0.001), respectively. Thus, the degree of background enhancement did not affect the specificity. For evaluating tumour extent (n = 104), the accuracy of MRI with moderate/marked background enhancement (52%) was significantly lower than that with minimal/mild background enhancement (84%; p = 0.002). The degree of background enhancement affected the detection and staging of breast cancer using MRI. (orig.)

  8. Identifying women with dense breasts at high risk for interval cancer: a cohort study.

    Science.gov (United States)

    Kerlikowske, Karla; Zhu, Weiwei; Tosteson, Anna N A; Sprague, Brian L; Tice, Jeffrey A; Lehman, Constance D; Miglioretti, Diana L

    2015-05-19

    Twenty-one states have laws requiring that women be notified if they have dense breasts and that they be advised to discuss supplemental imaging with their provider. To better direct discussions of supplemental imaging by determining which combinations of breast cancer risk and Breast Imaging Reporting and Data System (BI-RADS) breast density categories are associated with high interval cancer rates. Prospective cohort. Breast Cancer Surveillance Consortium (BCSC) breast imaging facilities. 365,426 women aged 40 to 74 years who had 831,455 digital screening mammography examinations. BI-RADS breast density, BCSC 5-year breast cancer risk, and interval cancer rate (invasive cancer ≤12 months after a normal mammography result) per 1000 mammography examinations. High interval cancer rate was defined as more than 1 case per 1000 examinations. High interval cancer rates were observed for women with 5-year risk of 1.67% or greater and extremely dense breasts or 5-year risk of 2.50% or greater and heterogeneously dense breasts (24% of all women with dense breasts). The interval rate of advanced-stage disease was highest (>0.4 case per 1000 examinations) among women with 5-year risk of 2.50% or greater and heterogeneously or extremely dense breasts (21% of all women with dense breasts). Five-year risk was low to average (0% to 1.66%) for 51.0% of women with heterogeneously dense breasts and 52.5% with extremely dense breasts, with interval cancer rates of 0.58 to 0.63 and 0.72 to 0.89 case per 1000 examinations, respectively. The benefit of supplemental imaging was not assessed. Breast density should not be the sole criterion for deciding whether supplemental imaging is justified because not all women with dense breasts have high interval cancer rates. BCSC 5-year risk combined with BI-RADS breast density can identify women at high risk for interval cancer to inform patient-provider discussions about alternative screening strategies. National Cancer Institute.

  9. Effect of different probiotics on breast quality characteristics of broilers under Salmonella challenge

    Directory of Open Access Journals (Sweden)

    Abdullah N. Al-Owaimer

    2014-07-01

    Full Text Available The current study was performed to investigate the influence of probiotics or antibiotic on breast quality characteristics of broiler chickens that were subjected to Salmonella challenge. Two hundred, one-day-old Cobb 500 chicks were allocated in five experimental treatments for 42 d. Ten cages of birds received one of the following treatments: T1=positive control (+CONT, unsupplemented, unchallenged; T2=negative control (-CONT, unsupplemented, challenged; T3=supplemented with antibiotic neoxyval (NEOX, challenged; T4=supplemented with probiotic Toyocerin (TOYO, challenged; and T5=supplemented with probiotic CloSTATTM (CLOS, challenged. Birds in treatments T2 to T5 were challenged with 3×109 CFU/mL of Salmonella enterica subsp. typhimurium on day 16. Nine birds per treatment were sampled at the end of the trial for breast characteristics. Overall, pH and temperature values of the breast muscle were similar among all groups tested. Cooking loss results indicated that breasts from T3 birds had the highest degree of shrinkage upon cooking while those of the probiotic group had similar control values (P<0.0001. Probiotic supplementation reduced the extent of destruction of myofibrils caused by homogenisation (P<0.0001. Warner-Bratzler shear test and texture profile analysis showed that neither treatments nor Salmonella challenge had any negative impact on texture or sensory attributes of chicken breast. In conclusion, results show that breast characteristics were better when probiotics were supplemented in the diets.

  10. Breast cancer treatment: historical review and current approaches

    International Nuclear Information System (INIS)

    Kulakowski, A.

    1994-01-01

    The evolution and development of opinions on the diagnosis and treatment of breast cancer since Galen to present time is presented. The concept of breast cancer as a local disease has been replaced by the understanding of its systemic character. On this background described are the methods of surgical treatment beginning from early - supraradical, to present -conservative approaches. The ''milestones'' in diagnosis and treatment of breast cancer of the last 40 years are presented. Current methods of breast cancer management include correct diagnosis (clinical examination, mammography, ultrasound, fine needle aspiration biopsy), TNM staging, adequate loco-regional therapy, systemic therapy, rehabilitation, reconstruction and careful follow-up. (author)

  11. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  12. Inverse scattering and refraction corrected reflection for breast cancer imaging

    Science.gov (United States)

    Wiskin, J.; Borup, D.; Johnson, S.; Berggren, M.; Robinson, D.; Smith, J.; Chen, J.; Parisky, Y.; Klock, John

    2010-03-01

    Reflection ultrasound (US) has been utilized as an adjunct imaging modality for over 30 years. TechniScan, Inc. has developed unique, transmission and concomitant reflection algorithms which are used to reconstruct images from data gathered during a tomographic breast scanning process called Warm Bath Ultrasound (WBU™). The transmission algorithm yields high resolution, 3D, attenuation and speed of sound (SOS) images. The reflection algorithm is based on canonical ray tracing utilizing refraction correction via the SOS and attenuation reconstructions. The refraction correction reflection algorithm allows 360 degree compounding resulting in the reflection image. The requisite data are collected when scanning the entire breast in a 33° C water bath, on average in 8 minutes. This presentation explains how the data are collected and processed by the 3D transmission and reflection imaging mode algorithms. The processing is carried out using two NVIDIA® Tesla™ GPU processors, accessing data on a 4-TeraByte RAID. The WBU™ images are displayed in a DICOM viewer that allows registration of all three modalities. Several representative cases are presented to demonstrate potential diagnostic capability including: a cyst, fibroadenoma, and a carcinoma. WBU™ images (SOS, attenuation, and reflection modalities) are shown along with their respective mammograms and standard ultrasound images. In addition, anatomical studies are shown comparing WBU™ images and MRI images of a cadaver breast. This innovative technology is designed to provide additional tools in the armamentarium for diagnosis of breast disease.

  13. Using Flow Characteristics in Three-Dimensional Power Doppler Ultrasound Imaging to Predict Complete Responses in Patients Undergoing Neoadjuvant Chemotherapy.

    Science.gov (United States)

    Shia, Wei-Chung; Huang, Yu-Len; Wu, Hwa-Koon; Chen, Dar-Ren

    2017-05-01

    Strategies are needed for the identification of a poor response to treatment and determination of appropriate chemotherapy strategies for patients in the early stages of neoadjuvant chemotherapy for breast cancer. We hypothesize that power Doppler ultrasound imaging can provide useful information on predicting response to neoadjuvant chemotherapy. The solid directional flow of vessels in breast tumors was used as a marker of pathologic complete responses (pCR) in patients undergoing neoadjuvant chemotherapy. Thirty-one breast cancer patients who received neoadjuvant chemotherapy and had tumors of 2 to 5 cm were recruited. Three-dimensional power Doppler ultrasound with high-definition flow imaging technology was used to acquire the indices of tumor blood flow/volume, and the chemotherapy response prediction was established, followed by support vector machine classification. The accuracy of pCR prediction before the first chemotherapy treatment was 83.87% (area under the ROC curve [AUC] = 0.6957). After the second chemotherapy treatment, the accuracy of was 87.9% (AUC = 0.756). Trend analysis showed that good and poor responders exhibited different trends in vascular flow during chemotherapy. This preliminary study demonstrates the feasibility of using the vascular flow in breast tumors to predict chemotherapeutic efficacy. © 2017 by the American Institute of Ultrasound in Medicine.

  14. Comparison between magnetic resonance findings and conventional techniques (ultrasonography and mammography) in breast disease

    International Nuclear Information System (INIS)

    Martin, J.L.; Garofono, J.M.; Berquet, A.; Fernandez, F.J.; Fuentes, P.; Alvarez de Cienfuegos, E.

    1996-01-01

    Although mammography is indisputably the best diagnostic method for detecting breast abnormalities, there are other techniques, such as ultrasonography and magnetic resonance, which are increasingly widely employed as additional indispensable aids. The present work compares mammography, ultrasound and magnetic resonance images of normal breast and of the major pathologies that can be observed in breast, including sclerosing adenosis, giant fibroadenoma, multifocal carcinoma, fibrocystic breast disease, infiltrating duct carcinoma, colloid carcinoma, radical scar, abscess and breast prosthesis. (Author) 10 refs

  15. A Wearable Goggle Navigation System for Dual-Mode Optical and Ultrasound Localization of Suspicious Lesions: Validation Studies Using Tissue-Simulating Phantoms and an Ex Vivo Human Breast Tissue Model.

    Directory of Open Access Journals (Sweden)

    Zeshu Zhang

    Full Text Available Surgical resection remains the primary curative treatment for many early-stage cancers, including breast cancer. The development of intraoperative guidance systems for identifying all sites of disease and improving the likelihood of complete surgical resection is an area of active ongoing research, as this can lead to a decrease in the need of subsequent additional surgical procedures. We develop a wearable goggle navigation system for dual-mode optical and ultrasound imaging of suspicious lesions. The system consists of a light source module, a monochromatic CCD camera, an ultrasound system, a Google Glass, and a host computer. It is tested in tissue-simulating phantoms and an ex vivo human breast tissue model. Our experiments demonstrate that the surgical navigation system provides useful guidance for localization and core needle biopsy of simulated tumor within the tissue-simulating phantom, as well as a core needle biopsy and subsequent excision of Indocyanine Green (ICG-fluorescing sentinel lymph nodes. Our experiments support the contention that this wearable goggle navigation system can be potentially very useful and fully integrated by the surgeon for optimizing many aspects of oncologic surgery. Further engineering optimization and additional in vivo clinical validation work is necessary before such a surgical navigation system can be fully realized in the everyday clinical setting.

  16. Differentiating benign from malignant solid breast masses: value of shear wave elastography according to lesion stiffness combined with greyscale ultrasound according to BI-RADS classification.

    Science.gov (United States)

    Evans, A; Whelehan, P; Thomson, K; Brauer, K; Jordan, L; Purdie, C; McLean, D; Baker, L; Vinnicombe, S; Thompson, A

    2012-07-10

    The aim of this study was to assess the performance of shear wave elastography combined with BI-RADS classification of greyscale ultrasound images for benign/malignant differentiation in a large group of patients. One hundred and seventy-five consecutive patients with solid breast masses on routine ultrasonography undergoing percutaneous biopsy had the greyscale findings classified according to the American College of Radiology BI-RADS. The mean elasticity values from four shear wave images were obtained. For mean elasticity vs greyscale BI-RADS, the performance results against histology were sensitivity: 95% vs 95%, specificity: 77% vs 69%, Positive Predictive Value (PPV): 88% vs 84%, Negative Predictive Value (NPV): 90% vs 91%, and accuracy: 89% vs 86% (all P>0.05). The results for the combination (positive result from either modality counted as malignant) were sensitivity 100%, specificity 61%, PPV 82%, NPV 100%, and accuracy 86%. The combination of BI-RADS greyscale and shear wave elastography yielded superior sensitivity to BI-RADS alone (P=0.03) or shear wave alone (P=0.03). The NPV was superior in combination compared with either alone (BI-RADS P=0.01 and shear wave P=0.02). Together, BI-RADS assessment of greyscale ultrasound images and shear wave ultrasound elastography are extremely sensitive for detection of malignancy.

  17. Point of Care Neonatal Ultrasound - Head, Lung, Gut and Line Localization.

    Science.gov (United States)

    Rath, Chandra; Suryawanshi, Pradeep

    2016-10-08

    Knowledge and skills of heart, head, lung, gut and basic abdominal ultrasound is of immense utility to clinicians in their day-to-day patient management, and in acute events, in the absence of specialist service back-up. This review examines the potential role of clinician-performed ultrasound in the neonatal intensive care unit. The bibliographic search of English-language literature was performed electronically using PubMed and EMBASE databases for the different topics we have covered under this review. Bedside head ultrasound can be used to identify and screen for intraventricular hemorrhage, periventricular leukomalacia and post-hemorrhagic ventricular dilatation. It is also a useful adjuvant tool in the evaluation of hypoxic ischemic encephalopathy. The relatively new lung ultrasound technique is useful in identifying transient tachypnea, pneumonia, pneumothorax, fluid overload and pleural effusion. Gut ultrasound is useful in identifying necrotizing enterocolitis and probably is better than X-ray in prognostication. Ultrasound is also useful in identifying vascular line positions without radiation exposure. Ultrasound performed by the clinician has an extensive role in the neonatal intensive care unit. Basic ultrasound knowledge of head, lung and gut is a useful supplement to clinical decision-making.

  18. Quality Assurance of Ultrasonic Diagnosis in Breast

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Kim, Hong Dae [Hallym University, Kangnam Sacred Heart Hospital, Seoul (Korea, Republic of)

    2006-06-15

    Sonography is a subjective diagnostic method which is highly dependent on the experience of the operator and the equipment quality which requires real-time adjustments. Breast screening examination currently consists of clinical examination and mammography. Breast sonography, either supplementary to mammography or independently, is indicated for the dense breast, especially in younger women. Breast sonography is especially applicable for Korean women because of the denser breast parenchyma and the approximately 10-year younger incidence rate of breast cancer of Korean women compared to western women. To avoid unnecessary breast biopsy because of the high rate of false positive lesions in breast parenchyma, which is different from other body organs such as the liver or the kidney, a quality assurance program for breast sonography is essential. The quality assurance of breast ultrasound involves quality assurance of the equipment, imaging display and acquisition of clinical images, personnel qualifications and other aspects such as unification of lexicon, guideline of diagnostic examination and reporting system; US BI-RAD reporting system, assessment items and organization, education program, medical audit, certification issues, and medicolegal issues. A breast sonographic quality assurance system should be established before a scheme to initiate governmental medical insurance for breast sonography

  19. Quality Assurance of Ultrasonic Diagnosis in Breast

    International Nuclear Information System (INIS)

    Chung, Soo Young; Kim, Hong Dae

    2006-01-01

    Sonography is a subjective diagnostic method which is highly dependent on the experience of the operator and the equipment quality which requires real-time adjustments. Breast screening examination currently consists of clinical examination and mammography. Breast sonography, either supplementary to mammography or independently, is indicated for the dense breast, especially in younger women. Breast sonography is especially applicable for Korean women because of the denser breast parenchyma and the approximately 10-year younger incidence rate of breast cancer of Korean women compared to western women. To avoid unnecessary breast biopsy because of the high rate of false positive lesions in breast parenchyma, which is different from other body organs such as the liver or the kidney, a quality assurance program for breast sonography is essential. The quality assurance of breast ultrasound involves quality assurance of the equipment, imaging display and acquisition of clinical images, personnel qualifications and other aspects such as unification of lexicon, guideline of diagnostic examination and reporting system; US BI-RAD reporting system, assessment items and organization, education program, medical audit, certification issues, and medicolegal issues. A breast sonographic quality assurance system should be established before a scheme to initiate governmental medical insurance for breast sonography

  20. Improving the nutritional quality and shelf life of broiler meat by feeding diets supplemented with fermented pomegranate (Punica granatum L.) by-products.

    Science.gov (United States)

    Ahmed, S T; Ko, S-Y; Yang, C-J

    2017-12-01

    1. Four experimental diets containing 0, 0.5, 1.0 and 2.0% fermented pomegranate by-products (FPB) were supplied to 320d-old broilers to evaluate the effects of FPB on growth performance, nutritional composition, fatty acid profile and oxidative stability of meat. 2. Dietary supplementation of FPB linearly increased the weight gain and feed intake of broilers with linear reduction in feed conversion ratio. 3. The crude protein, iron, magnesium, and sodium content were linearly higher, whereas cholesterol was linearly lower in the breast meat of FPB-supplemented broilers. In thigh meat, linearly lower ether extract and cholesterol with higher moisture was noted in response to increasing levels of FPB. 4. The proportion of saturated fatty acids was both linearly and quadratically lower in breast and thigh meat, whereas those of monounsaturated fatty acids of breast (linear and quadratic) and n-3 fatty acids of breast and thigh (linear) meat was higher in the FPB-supplemented broilers. The n-6/n-3 ratio of breast meat was linearly lower in response to FPB supplementation. The hypocholesterolaemic to hypercholesterolaemic ratio of thigh meat was higher in the FPB-supplemented groups. 5. The thiobarbituric acid reactive substances and pH value were lower in the breast and thigh meat of FPB-supplemented broilers. 6. Thus, additive supplementation of the diet with up to 2% FPB improved the nutritional quality, fatty acid profile and shelf life of broiler meat.

  1. [Diagnostic imaging of breast cancer : An update].

    Science.gov (United States)

    Funke, M

    2016-10-01

    Advances in imaging of the female breast have substantially influenced the diagnosis and probably also the therapy and prognosis of breast cancer in the past few years. This article gives an overview of the most important imaging modalities in the diagnosis of breast cancer. Digital mammography is considered to be the gold standard for the early detection of breast cancer. Digital breast tomosynthesis can increase the diagnostic accuracy of mammography and is used for the assessment of equivocal or suspicious mammography findings. Other modalities, such as ultrasound and contrast-enhanced magnetic resonance imaging (MRI) play an important role in the diagnostics, staging and follow-up of breast cancer. Percutaneous needle biopsy is a rapid and minimally invasive method for the histological verification of breast cancer. New breast imaging modalities, such as contrast-enhanced spectral mammography, diffusion-weighted MRI and MR spectroscopy can possibly further improve breast cancer diagnostics; however, further studies are necessary to prove the advantages of these methods so that they cannot yet be recommended for routine clinical use.

  2. Fish oil supplementation improves docosahexaenoic acid status of malnourished infants

    NARCIS (Netherlands)

    Smit, EN; Oelen, EA; Seerat, E; Boersma, ER; Muskiet, FAJ

    Aim-To investigate whether the low docosahexaenoic acid (DHA) status of malnourished, mostly breast fed, Pakistani children can be improved by fish oil (FO) supplementation. Methods-Ten malnourished children (aged 8-30 months) received 500 mg FO daily for nine weeks. The supplement contained 62.8

  3. Breast disease with skin thickening: differential diagnosis with mammography and ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Young Rok; Kim, Hak Hee; Cha, Eun Suk; Park, Hye Seong; Kim, Ki Tae; Shinn, Kyung Sub [The Catholic University of Korea College of Medicine, Seoul (Korea, Republic of)

    1999-02-01

    Diffuse skin thickening of the breast is produced by lymphedema usually secondary to obstruction of the axillary lymphatics. On physical examination, the affected breast is, due to increased fluid content, larger, heavier, and of higher overall density. Mammography reveals an increased coarse reticular pattern. Thickening of the skin can have many causes. It may be a result of tumor invasion or a tumor in the dermal lymphatics ; or because of lymphatic congestion through obstruction of lymphatic drainage within the breast, in the axilla, or centrally in the mediastinum. Further causes may be congestive heart failure, benign inflammation, primary skin processes such as psoriasis, or systemic diseases which involve the skin. Mammographic appearance is known to be nonspecific. Ultrasound can demonstrate skin thickening directly, but despite some reports suggesting that the cause of skin thickening can be inferred from the results of ultrasound, this is not usually of practical importance. The purpose of this study is to review the causes of skin thickening of the breast and to use mammography and US to differentiate the causes.

  4. Computer Aided Theragnosis Using Quantitative Ultrasound Spectroscopy and Maximum Mean Discrepancy in Locally Advanced Breast Cancer.

    Science.gov (United States)

    Gangeh, Mehrdad J; Tadayyon, Hadi; Sannachi, Lakshmanan; Sadeghi-Naini, Ali; Tran, William T; Czarnota, Gregory J

    2016-03-01

    A noninvasive computer-aided-theragnosis (CAT) system was developed for the early therapeutic cancer response assessment in patients with locally advanced breast cancer (LABC) treated with neoadjuvant chemotherapy. The proposed CAT system was based on multi-parametric quantitative ultrasound (QUS) spectroscopic methods in conjunction with advanced machine learning techniques. Specifically, a kernel-based metric named maximum mean discrepancy (MMD), a technique for learning from imbalanced data based on random undersampling, and supervised learning were investigated with response-monitoring data from LABC patients. The CAT system was tested on 56 patients using statistical significance tests and leave-one-subject-out classification techniques. Textural features using state-of-the-art local binary patterns (LBP), and gray-scale intensity features were extracted from the spectral parametric maps in the proposed CAT system. The system indicated significant differences in changes between the responding and non-responding patient populations as well as high accuracy, sensitivity, and specificity in discriminating between the two patient groups early after the start of treatment, i.e., on weeks 1 and 4 of several months of treatment. The proposed CAT system achieved an accuracy of 85%, 87%, and 90% on weeks 1, 4 and 8, respectively. The sensitivity and specificity of developed CAT system for the same times was 85%, 95%, 90% and 85%, 85%, 91%, respectively. The proposed CAT system thus establishes a noninvasive framework for monitoring cancer treatment response in tumors using clinical ultrasound imaging in conjunction with machine learning techniques. Such a framework can potentially facilitate the detection of refractory responses in patients to treatment early on during a course of therapy to enable possibly switching to more efficacious treatments.

  5. Efficiency of Imaging Modalities in Male Breast Disease: Can Ultrasound Give Additional Information for Assessment of Gynecomastia Evolution?

    Science.gov (United States)

    Sarıca, Özgür; Kahraman, A. Nedim; Öztürk, Enis; Teke, Memik

    2018-01-01

    Objective The purpose of this study is to present mammography and ultrasound findings of male breast lesions and to investigate the ability of diagnostic modalities in estimating the evolution of gynecomastia. Materials and Methods Sixty-nine male patients who admitted to Taksim and Bakirkoy Education and Research Hospitals and underwent mammography (MG) and ultrasonography (US) imaging were retrospectively evaluated. Duration of symptoms and mammographic types of gynecomastia according to Appelbaum’s classifications were evaluated, besides the sonographic findings in mammographic types of gynecomastia. Results The distribution of 69 cases were as follows: gynecomastia 47 (68.11%), pseudogynecomastia 6 (8.69%) primary breast carcinoma 7 (10.14%), metastatic carcinoma 1 (1.4%), epidermal inclusion cyst 2 (2.8%), abscess 2 (2.8%), lipoma 2 (2.8%), pyogenic granuloma 1 (1.4%), and granulomatous lobular mastitis 1 (1.4%). Gynecomastia patients who had symptoms less than 1 year had nodular gynecomastia (34.6%) as opposed to dendritic gynecomastia (61.5%) (pgynecomastia (70%) had a higher rate than the dendritic type (20%). Patients having the symptoms more than 2 years had diffuse gynecomastia (57.1%) while 42.9% had dendritic gynecomastia (pgynecomastia (92.3%) than noduler type (1.9 %). Patients having symptoms for 1 to 2 years had more dentritic gynecomastia (70%) than diffuse type (30%). Patients having symptoms more than 2 years had diffuse gynecomastia (57.1%) comparable to dendritic gynecomastia (42.9 %). Conclusion Diagnostic imaging modalities are efficient tools for estimation of gynecomastia evolution as well as the diagnosis of other male breast diseases. There seems to be an incongruity between duration of clinical complaints and diagnostic imaging classification of gynecomastia. The use of these high resolution US findings may demonstrate an early phase fibrosis especially in patients visualized by mammography as with nodular phase. PMID:29322116

  6. Primary non-Hodgkin's lymphoma of breast – A rare cause of breast lump

    Directory of Open Access Journals (Sweden)

    Veena Gupta

    2017-03-01

    Full Text Available We, here, report a case of primary breast lymphoma in a 59 years old female. The diagnosis was suspected on fine needle aspiration cytology and confirmed on excision biopsy of the tumor. Histology and immunophenotyping were in accordance with non-Hodgkin's diffuse large B-cell lymphoma. The patient has been planned for adjuvant chemoradiation. The management and outcome of primary breast lymphoma and carcinoma are totally different. Early and prompt diagnosis of primary breast lymphoma is of utmost importance to avoid unnecessary mastectomies. Fine needle aspiration cytology supplemented by immuno-cytochemistry can be applied as a reliable and cost-effective tool in the early diagnosis of primary breast lymphomas, while histopathology and immunohistochemistry are conclusive.

  7. Preparation and administration of I-125 labeled seeds for localization of nonpalpable breast lesions

    DEFF Research Database (Denmark)

    Langhans, Linnea; Klausen, Thomas Levin; Tvedskov, Tove Holst Filtenborg

    2016-01-01

    Radioactive seed localization (RSL) is a new technique for surgical identification of nonpalpable breast lesions. We describe the preparation of the needle with I-125 seeds for ultrasound-guided deposition in breast lesions. In a feasibility study we investigated the minimum activity amount needed...... for reliable gamma probe identification of the seeds and the levels of exposure to the staff. METHODS: 11 patients received a seed, which was manually placed in an 18 gauge needle with bone wax occluding the tip, and the radiologist introduced it into the breast tissue guided by ultrasound. The seed...... identified. The surgeon removed the seeds together with the breast lesions, and they were identified by the pathologist. There were no unexpected adverse drug reactions. Water bath studies suggest that 1-3 MBq I-125 was sufficient for precise identification, regardless of the presence of conventional Tc-99m...

  8. What we need to know about dense breasts: implications for breast cancer screening.

    Science.gov (United States)

    Carreira Gómez, M C; Estrada Blan, M C

    High breast density and its relationship to the risk of breast cancer has become a hot topic in the medical literature and in the lay press, especially in the United States, where it has brought about changes in the legal framework that require radiologists to inform clinicians and patients about breast density. Radiologists, who are mainly responsible for this information, need to know the scientific evidence and controversies regarding this subject. The discussion is centered on the real importance of the risk, the limitation that not having standardized methods of measurement represents, and the possible application of complementary screening techniques (ultrasound, magnetic resonance imaging, or tomosynthesis) for which clear recommendations have yet to be established. We need controlled studies that evaluate the application of these techniques in women with dense breasts, including the possibility that they can lead to overdiagnosis. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Computed tomography (CT), nuclear medicine (NM), and ultrasound (US) in oncology patients

    International Nuclear Information System (INIS)

    McNeil, B.J.

    1982-01-01

    This review will summarize the effectiveness of computed tomography, ultrasound, and nuclear medicine imaging procedures in several different disease processes. The results indicate: (1) CT is clearly better than ultrasound for diseases of the adrenal gland and pancreas; (2) for patients with gynecologic malignancies, CT and ultrasound are approximately equivalent in their ability to define treatment options effectively; (3) in the liver, the differences among the three modalities are less marked and are disease specific. For example, for patients with colon cancer the increased effectiveness of CT relative to ultrasound or nuclear medicine is small. For patients with breast cancer, the difference is greater; (4) for patients suspected to have a focal source of sepsis, CT is slightly better than ultrasound or nuclear medicine. In these patients, however, when nuclear medicine images are obtained on a rectilinear scanner, the results are significantly worse compared to nuclear medicine images on a LFOV gamma camera or to ultrasound. As a result of the above studies and concommitant statistical analyses, several conclusions can be drawn about optimum experimental design and statistical approaches for comparing imaging modalities

  10. Do acute-care surgeons follow best practices for breast abscess management? A single-institution analysis of 325 consecutive cases.

    Science.gov (United States)

    Barron, Alison Unzeitig; Luk, Stephen; Phelan, Herb A; Williams, Brian H

    2017-08-01

    The breast surgery community has adopted needle aspiration as the standard of care for breast abscesses, which have a size less than 5 cm on ultrasound, no skin changes, and fewer than 5 days of symptoms. Our acute-care surgery (ACS) service manages all breast abscess consults at our urban safety-net hospital. We undertook this descriptive study to identify the rate of operative incisions and drainage performed by ACS surgeons which were not compatible with best practices for breast abscess management. We performed a retrospective review of the electronic health records of all patients on whom the ACS service was consulted for a breast abscess at our urban safety-net hospital between January 2010 and December 2014. We collected data on patient demographics, breast skin characteristics, length of symptoms, ultrasound results, and treatment modality. A total of 325 patients with breast abscesses were evaluated by ACS, of whom 21 met the breast community's indications for needle aspiration. Of the overall 325 subject sample, 281 (86.5%) underwent incision and drainage (I&D), and 44 (13.5%) underwent bedside needle aspiration. Of the 281 patients that underwent I&D, 269 (95.7%) met the breast surgery community's indications for I&D due to either skin changes (n = 90, 33.5%), abscess >5 cm on ultrasound (n = 88, 32.7%), or symptoms >5 days (n = 238, 88.5%). Of the 44 patients that underwent needle aspiration, only 9 (20.5%) met the current practice indications for aspiration. Of the 44 patients that underwent aspiration, 28 (63.6%) failed and went on to have an operation. The majority of these failed aspirations had symptoms >5 days (23 patients, 82.1%) or had skin changes at presentation (1 patient, 3.6%) or an abscess >5 cm on ultrasound (5 patients, 17.9%). As judged by best practices promulgated by the breast surgery community, ACS surgeons do not show excessive rates of operative I&D of breast abscess and in fact seem to overutilize needle aspiration

  11. CLINICAL BREAST EXAMINATION SCREENING BY TRAINED LAYWOMEN IN MALAWI INTEGRATED WITH OTHER HEALTH SERVICES.

    Science.gov (United States)

    Gutnik, L; Lee, C; Msosa, J

    2017-06-01

    Breast cancer awareness and early detection are limited in Sub-Saharan Africa. Resource limitations make screening mammography or clinical breast examination (CBE) by physicians or nurses impractical in many settings. Four laywomen were trained to deliver breast cancer educational talks and conduct CBE. After training, screening was implemented in diverse urban health clinics. Eligible women were 30 years old, with no prior breast cancer or breast surgery, and clinic attendance for reasons other than a breast concern. Women with abnormal CBE were referred to a study surgeon. All palpable masses confirmed by surgeon examination were pathologically sampled. Patients with abnormal screening CBE but normal surgeon examination underwent breast ultrasound confirmation. In addition, 50 randomly selected women with normal screening CBE underwent breast ultrasound, and 45 different women with normal CBE were randomly assigned to surgeon examination. Among 1220 eligible women, 1000 (82%) agreed to CBE. Lack of time (69%) was the commonest reason for refusal. Educational talk attendance was associated with higher CBE participation (83% versus 77%, P ¼ 0.012). Among 1000 women screened, 7% had abnormal CBE. Of 45 women with normal CBE randomised to physician examination, 43 had normal examinations and two had axillary lymphadenopathy not detected by CBE. Sixty of 67 women (90%) with abnormal CBE attended the referral visit. Of these, 29 (48%) had concordant abnormal physician examination. Thirty-one women (52%) had discordant normal physician examination, all of whom also had normal breast ultrasounds. Compared with physician examination, sensitivity for CBE by laywomen was 94% (confidence interval [CI] 79%-99%), specificity 58% (CI, 46%-70%), positive predictive value 48% (CI, 35%-62%), and negative predictive value 96% (CI, 85%-100%). Of 13 women who underwent recommended pathologic sampling of a breast lesion, two had cytologic dysplasia and all others benign Results. CBE

  12. Breast composition: Measurement and clinical use

    International Nuclear Information System (INIS)

    Ekpo, E.U.; Hogg, P.; Highnam, R.; McEntee, M.F.

    2015-01-01

    Breast density is a measure of the extent of radiodense fibroglandular tissue in the breast. The risk of developing breast cancer and the risk of missing cancer at screening rise with higher breast density. In this paper, the historical background to breast density measurement is outlined and current evidence based practice is explained. The relevance of breast density knowledge to mammographic practice and image interpretation is considered in the light of clinical assessment and notification of mammographic breast density (MBD). The current work also discusses risk stratification for decision-making regarding screening frequency and better modalities for earlier detection of breast cancer in the dense breast. Automated volumetric approaches are explained while ultrasound, digital breast tomosynthesis, molecular breast imaging, and magnetic resonance imaging are introduced as valuable adjuncts to digital mammography for imaging the dense breast. The work concludes on the important note that screened women should be notified of their breast density, and such notification should be accompanied with clear and adequate information about breast density and cancer risk, strategies associated with lower MBD, as well as best screening intervals and pathways for women with dense breasts. Adoption of these strategies may be crucial to early detection and treatment of cancer and improving survival from the disease. - Highlights: • Breast density is associated with breast cancer risk and interval breast cancer. • Breast density can be measured manually or automatically. • Radiographic exposure factors impact on breast density measurements. • Dense breast often require imaging with three-dimensional modalities. • National breast density data could enable breast cancer risk stratification.

  13. Effect of Noni Leaves Extract (Morinda citrifolia L. Supplementation in Feed on Physical Quality of Broiler Breast Meat

    Directory of Open Access Journals (Sweden)

    Aji Sukoco

    2015-08-01

    Full Text Available This research was conducted to know the effect of noni leaves extract (Morinda citrifolia L. supplementation in feed on physical quality of broiler breast meat such as pH, Water Holding Capacity (WHC, Cooking Loss (CL, and tenderness. Ninety six 8-days old broiler chickens strain Lohmann and of undifferentiated sex (unsexed were used in this research. The broiler chickens will be reared until 35-days old. The research method was experimental using Completely Randomized Design (CRD with six treatments and four replications, each replication consisted of four broiler chickens. The treatments consisted of P0 (Basal Feed, P1 (Basal Feed + tetracycline 0.05%, P2 (Basal Feed + noni leaves extract 0.05%, P3 (Basal feed + noni leaves extract 0.1%, P4 (Basal feed + noni leaves extract 0.15%, P5 (Basal feed + noni leaves extract 0.2%. The data were analyzed by ANOVA and continued by Least Significant Difference (LSD test if there was significantly different result. The results showed that noni leaves extract did not give significant effect (P>0.05 on meat pH, water holding capacity (WHC, cooking loss (CL, and tenderness. However, these results were still acceptable normally such as pH between 5.38-5.57, water holding capacity 34.13-45.64%, cooking loss 33.05-36.97%, but tenderness 16.22-20.57N were less acceptable. The research concluded that supplementation of noni leaves extract (Morinda citrifolia L. in feed did not increase physical quality of broiler breast meat on pH, Water Holding Capacity (WHC, Cooking Loss (CL, and tenderness.

  14. Mammographic classification of breast lesions amongst women in ...

    African Journals Online (AJOL)

    These lesions' diagnosis can be accom- plished with ... estimated 246,660 new cases of the invasive breast cancer are expected to be diagnosed in women in the US. Mam- ... as ultrasound and magnetic resonance imaging (MRI)4. However ...

  15. Does the degree of background enhancement in breast MRI affect the detection and staging of breast cancer?

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, Takayoshi [Shizuoka Cancer Center Hospital, Breast Imaging and Breast Intervention Section, Shizuoka (Japan); Kasami, Masako [Shizuoka Cancer Center Hospital, Department of Pathology, Naga-izumi, Shizuoka (Japan); Watanabe, Junichiro [Shizuoka Cancer Center Hospital, Division of Medical Oncology, Naga-izumi, Shizuoka (Japan)

    2011-11-15

    The purpose of this study was to assess the influence of background enhancement on the detection and staging of breast cancer using MRI as an adjunct to mammography or ultrasound. One hundred forty-six bilateral breast MRI examinations were evaluated to assess the extent of a known primary tumour and to problem solve after mammography or ultrasound without adjusting for the phase in the patients' menstrual cycle. The background enhancement was classified into four categories by visual evaluation: minimal, mild, moderate and marked. In total, 131 histologically confirmed abnormal cases (104 malignant and 27 benign) and 15 normal cases were included in the analysis. There was no tumour size-related bias between the groups (p = 0.522). For the primary index tumour, the sensitivities of MRI with minimal/mild and moderate/marked background enhancement were 100% and 76% (p = 0.001), respectively. Thus, the degree of background enhancement did not affect the specificity. For evaluating tumour extent (n = 104), the accuracy of MRI with moderate/marked background enhancement (52%) was significantly lower than that with minimal/mild background enhancement (84%; p = 0.002). The degree of background enhancement affected the detection and staging of breast cancer using MRI. (orig.)

  16. Integrated screening concept in women with genetic predisposition for breast cancer

    International Nuclear Information System (INIS)

    Bick, U.

    1997-01-01

    Breast cancer is in 5% of cases due to a genetic disposition. BRCA1 and BRCA2 are by far the most common breast cancer susceptibility genes. For a woman with a genetic predisposition, the individual risk of developing breast cancer sometime in her life is between 70 and 90%. Compared to the spontaneous forms of breast cancer, woman with a genetic predisposition often develop breast cancer at a much younger age. This is why conventional screening programs on the basis of mammography alone cannot be applied without modification to this high-risk group. In this article, an integrated screening concept for women with genetic prodisposition for breast cancer using breast self-examination, clinical examination, ultrasound, mammography and magnetic resonance imaging is introduced. (orig.) [de

  17. Surveillance mammography for detecting ipsilateral breast tumour recurrence and metachronous contralateral breast cancer: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Clare; Boachie, Charles; Fraser, Cynthia; MacLennan, Graeme; Mowatt, Graham; Thomas, Ruth E. [University of Aberdeen, Health Services Research Unit, Aberdeen (United Kingdom); Ragupathy, Senthil Kumar Arcot [NHS Grampian, Radiology Department, Aberdeen Royal Infirmary, Aberdeen (United Kingdom); Heys, Steve D. [University of Aberdeen and Aberdeen Royal Infirmary, NHS Grampian, Division of Applied Medicine, School of Medicine and Dentistry, Aberdeen (United Kingdom); Gilbert, Fiona J. [University of Aberdeen and Aberdeen Royal Infirmary, NHS Grampian, Aberdeen Biomedical Imaging Centre, Aberdeen (United Kingdom)

    2011-12-15

    To determine the diagnostic accuracy of surveillance mammography for detecting ipsilateral breast tumour recurrence and metachronous contralateral breast cancer in women previously treated for primary breast cancer. A systematic review of surveillance mammography compared with ultrasound, magnetic resonance imaging (MRI), specialist-led clinical examination or unstructured primary care follow-up, using histopathological assessment for test positives and follow-up for test negatives as the reference standard. Nine studies met our inclusion criteria. Variations in study comparisons precluded meta-analysis. For routine ipsilateral breast tumour detection, surveillance mammography sensitivity ranged from 64-67% and specificity ranged from 85-97%. For MRI, sensitivity ranged from 86-100% and specificity was 93%. For non-routine ipsilateral breast tumour detection, sensitivity and specificity for surveillance mammography ranged from 50-83% and 57-75% and for MRI 93-100% and 88-96%. For routine metachronous contralateral breast cancer detection, one study reported sensitivity of 67% and specificity of 50% for both surveillance mammography and MRI. Although mammography is associated with high sensitivity and specificity, MRI is the most accurate test for detecting ipsilateral breast tumour recurrence and metachronous contralateral breast cancer in women previously treated for primary breast cancer. Results should be interpreted with caution because of the limited evidence base. (orig.)

  18. Imaging Spectrums of the Male Breast Diseases: A Pictorial Essay

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hye Jeong; Choi, Seon Hyeong; Ahn, Hye Kyung; Chung, Soo Young [Dept. of Radiology, Kangnam Scred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of); Yang Ik [Dept. of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of); Jung, Ah young [Dept. of Pathology, Kangnam Scred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    Most described male breast lesions, such as gynecomastia, are benign. The overall incidence of male breast cancer is less than 3%. Like women, common presentations of male breast diseases are palpable lumps or tenderness. Physical examination, mammography and ultrasound are generally used for work-up of breast diseases in both women and men. However, men do not undergo screening mammograms; all male patients are examined in symptomatic cases only. Therefore, all male breast examinations are diagnostic, whereas the majority of the examinations for women are for screening purpose. The differentiation between benign and malignant breast lesions is important, especially for men, because the reported prognosis of male breast cancer is poor due to delayed diagnosis. In this article, we review the spectrum of male breast diseases, from benign to malignant, and illustrate their ultrasonographic and mammographic imaging features.

  19. Imaging Spectrums of the Male Breast Diseases: A Pictorial Essay

    International Nuclear Information System (INIS)

    Kim, Hye Jeong; Choi, Seon Hyeong; Ahn, Hye Kyung; Chung, Soo Young; Yang Ik; Jung, Ah young

    2011-01-01

    Most described male breast lesions, such as gynecomastia, are benign. The overall incidence of male breast cancer is less than 3%. Like women, common presentations of male breast diseases are palpable lumps or tenderness. Physical examination, mammography and ultrasound are generally used for work-up of breast diseases in both women and men. However, men do not undergo screening mammograms; all male patients are examined in symptomatic cases only. Therefore, all male breast examinations are diagnostic, whereas the majority of the examinations for women are for screening purpose. The differentiation between benign and malignant breast lesions is important, especially for men, because the reported prognosis of male breast cancer is poor due to delayed diagnosis. In this article, we review the spectrum of male breast diseases, from benign to malignant, and illustrate their ultrasonographic and mammographic imaging features.

  20. Diagnostic features of quantitative comb-push shear elastography for breast lesion differentiation.

    Science.gov (United States)

    Bayat, Mahdi; Denis, Max; Gregory, Adriana; Mehrmohammadi, Mohammad; Kumar, Viksit; Meixner, Duane; Fazzio, Robert T; Fatemi, Mostafa; Alizad, Azra

    2017-01-01

    Lesion stiffness measured by shear wave elastography has shown to effectively separate benign from malignant breast masses. The aim of this study was to evaluate different aspects of Comb-push Ultrasound Shear Elastography (CUSE) performance in differentiating breast masses. With written signed informed consent, this HIPAA- compliant, IRB approved prospective study included patients from April 2014 through August 2016 with breast masses identified on conventional imaging. Data from 223 patients (19-85 years, mean 59.93±14.96 years) with 227 suspicious breast masses identifiable by ultrasound (mean size 1.83±2.45cm) were analyzed. CUSE was performed on all patients. Three regions of interest (ROI), 3 mm in diameter each, were selected inside the lesion on the B-mode ultrasound which also appeared in the corresponding shear wave map. Lesion elasticity values were measured in terms of the Young's modulus. In correlation to pathology results, statistical analyses were performed. Pathology revealed 108 lesions as malignant and 115 lesions as benign. Additionally, 4 lesions (BI-RADS 2 and 3) were considered benign and were not biopsied. Average lesion stiffness measured by CUSE resulted in 84.26% sensitivity (91 of 108), 89.92% specificity (107 of 119), 85.6% positive predictive value, 89% negative predictive value and 0.91 area under the curve (P 0.21). CUSE was able to distinguish between benign and malignant breast masses with high sensitivity and specificity. Continuity of stiffness maps allowed for choosing multiple quantification ROIs which covered large areas of lesions and resulted in similar diagnostic performance based on average and maximum elasticity. The overall results of this study, highlights the clinical value of CUSE in differentiation of breast masses based on their stiffness.

  1. Diagnostic features of quantitative comb-push shear elastography for breast lesion differentiation.

    Directory of Open Access Journals (Sweden)

    Mahdi Bayat

    Full Text Available Lesion stiffness measured by shear wave elastography has shown to effectively separate benign from malignant breast masses. The aim of this study was to evaluate different aspects of Comb-push Ultrasound Shear Elastography (CUSE performance in differentiating breast masses.With written signed informed consent, this HIPAA- compliant, IRB approved prospective study included patients from April 2014 through August 2016 with breast masses identified on conventional imaging. Data from 223 patients (19-85 years, mean 59.93±14.96 years with 227 suspicious breast masses identifiable by ultrasound (mean size 1.83±2.45cm were analyzed. CUSE was performed on all patients. Three regions of interest (ROI, 3 mm in diameter each, were selected inside the lesion on the B-mode ultrasound which also appeared in the corresponding shear wave map. Lesion elasticity values were measured in terms of the Young's modulus. In correlation to pathology results, statistical analyses were performed.Pathology revealed 108 lesions as malignant and 115 lesions as benign. Additionally, 4 lesions (BI-RADS 2 and 3 were considered benign and were not biopsied. Average lesion stiffness measured by CUSE resulted in 84.26% sensitivity (91 of 108, 89.92% specificity (107 of 119, 85.6% positive predictive value, 89% negative predictive value and 0.91 area under the curve (P 0.21.CUSE was able to distinguish between benign and malignant breast masses with high sensitivity and specificity. Continuity of stiffness maps allowed for choosing multiple quantification ROIs which covered large areas of lesions and resulted in similar diagnostic performance based on average and maximum elasticity. The overall results of this study, highlights the clinical value of CUSE in differentiation of breast masses based on their stiffness.

  2. Shear-wave elastography in breast ultrasonography: the state of the art

    Directory of Open Access Journals (Sweden)

    Ji Hyun Youk

    2017-10-01

    Full Text Available Shear-wave elastography (SWE is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy.

  3. Shear-wave elastography in breast ultrasonography: the state of the art

    Energy Technology Data Exchange (ETDEWEB)

    Youk, Ji Hyun; Gweon, Hye Mi; Son, Eun Ju [Dept. of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Shear-wave elastography (SWE) is a recently developed ultrasound technique that can visualize and measure tissue elasticity. In breast ultrasonography, SWE has been shown to be useful for differentiating benign breast lesions from malignant breast lesions, and it has been suggested that SWE enhances the diagnostic performance of ultrasonography, potentially improving the specificity of conventional ultrasonography using the Breast Imaging Reporting and Data System criteria. More recently, not only has SWE been proven useful for the diagnosis of breast cancer, but has also been shown to provide valuable information that can be used as a preoperative predictor of the prognosis or response to chemotherapy.

  4. Effects of the Dietary Supplementation of Sucupira (Pterodon Emarginatus Vog. and Copaiba (Copaifera Langsdorffii Resinoils on Chicken Breast and Thigh Meat Quality and Oxidative Stability

    Directory of Open Access Journals (Sweden)

    CB de Lima

    2015-12-01

    Full Text Available ABSTRACT An experiment was conducted to evaluate the addition of the oil resins ofsucupira (Pterodon emarginatus Vog. and copaiba (Copaifera langsdorffii to broiler diets on chicken meat composition, quality, and lipid peroxidation. 350 one-d-old broiler chicks were submitted to seven treatments, consisting of the diets supplemented with copaiba (COP or sucupira (SUC resin oils at three different concentrations (500, 900, and 1300 ppm plus a negative control diet (CONT. At 37 days of age, 10 birds per treatment were selected according to the average weight of the experimental unit and slaughtered to collect breast and thigh meat, which was stored at 4°C for 24 hours to evaluate pH, color (L*, a*, b*, cooking weight loss (CWL, and shear force (SF. Raw meat was vacuum packed and stored frozen until lipid peroxidation analysis. Meat samples were pooled to prepare pre-cooked meatballs (30 ± 0.5g, stored under refrigeration (eight days, and analyzed every two days for TBARS concentration. Results were analyzed using the PROC GLM and MIXED procedures (SAS statistical software. Plant oils increased (p<0.05 breast meat humidity (HU and crude protein (CP levels and reduced (p<0.05 total lipid (TLC and ash (AS levels when compared with the CONT treatment. Plant oils increased (p<0.05 thigh meat HU when compared with the CONT. High COP dietary levels reduced (p<0.05 breast meat CWL, and increased (p<0.05 thigh meat L* values when compared to CONT, except for SUC500 and SUC900. The dietary inclusion of plant oil resins showed a pro-oxidant effect (p<0.01 on breast meat when compared with the CONT. Low SUC dietary supplementation levels significantly reduced (p<0.01 the concentration of secondary oxidation products in thigh meat.

  5. Measurement of breast volume is a useful supplement to select candidates for surgical breast reduction

    DEFF Research Database (Denmark)

    Ikander, Peder; Drejøe, Jennifer Berg; Lumholt, Pavia

    2014-01-01

    INTRODUCTION: The indication for breast reduction in a public welfare or an insurance paid setting depends on the severity of the subjective symptoms and the clinical evaluation. The purpose of this study was to evaluate the use of breast volume as an objective criterion to establish the indication...

  6. Comparison of Sonography versus Digital Breast Tomosynthesis to Locate Intramammary Marker Clips.

    Science.gov (United States)

    Schulz-Wendtland, R; Dankerl, P; Dilbat, G; Bani, M; Fasching, P A; Heusinger, K; Lux, M P; Loehberg, C R; Jud, S M; Rauh, C; Bayer, C M; Beckmann, M W; Wachter, D L; Uder, M; Meier-Meitinger, M; Brehm, B

    2015-01-01

    Introduction: This study aimed to compare the accuracy of sonography versus digital breast tomosynthesis to locate intramammary marker clips placed under ultrasound guidance. Patients and Methods: Fifty patients with suspicion of breast cancer (lesion diameter less than 2 cm [cT1]) had ultrasound-guided core needle biopsy with placement of a marker clip in the center of the tumor. Intramammary marker clips were subsequently located with both sonography and digital breast tomosynthesis. Results: Sonography detected no dislocation of intrammammary marker clips in 42 of 50 patients (84 %); dislocation was reported in 8 patients (16 %) with a maximum dislocation of 7 mm along the x-, y- or z-axis. Digital breast tomosynthesis showed accurate placement without dislocation of the intramammary marker clip in 48 patients (96 %); 2 patients (4 %) had a maximum clip dislocation of 3 mm along the x-, y- or z-axis (p tomosynthesis could improve the accuracy when locating intramammary marker clips compared to sonography and could, in future, be used to complement or even completely replace sonography.

  7. The value of preoperative ultrasound guided fine-needle aspiration cytology of radiologically suspicious axillary lymph nodes in breast cancer

    Directory of Open Access Journals (Sweden)

    Torill Sauer

    2014-01-01

    Full Text Available Background: Preoperative ultrasound (US and eventually US-guided fine-needle aspiration cytology (FNAC of suspicious axillary lymph nodes (ALN is a standard procedure in the work-up of suspicious breast lesions. Preoperative US FNAC may prevent sentinel node biopsy (SNB procedure in 24-30% of patients with early stage breast carcinoma. The aim of this study was to evaluate the institutional results of this preoperative diagnostic procedure. Materials and Methods: A total of 182 cases of preoperative FNAC of suspicious ALN where retrieved from the pathology files. The results were compared with the final histology and staging. False negative (FN FNAC cases were reviewed and possibly missed metastatic cases (2 were immunostained with the epithelial marker AE1/AE3. Results: There were no false positives, whereas 16 cases were FN. In all but one case the FN′s represented sampling error. Half of the 16 FN cases in this series were macrometastases. Discussion: About 83% of the preoperatively aspirated cases were N+, indicating that a radiologically suspicious ALN has a very high risk of being metastatic. Preoperative US guided FNAC from radiologically suspicious ALN is highly efficient in detecting metastases. Depending on national guidelines, a preoperative, positive ALN FNAC might help to stratify the patients as to SNB and/or ALN dissection.

  8. Investigation of variability in image acquisition and contouring during 3D ultrasound guidance for partial breast irradiation

    International Nuclear Information System (INIS)

    Landry, Anthony; Olivotto, Ivo; Beckham, Wayne; Berrang, Tanya; Gagne, Isabelle; Popescu, Carmen; Mitchell, Tracy; Vey, Hazel; Sand, Letricia; Soh, Siew Yan; Wark, Jill

    2014-01-01

    Three-dimensional ultrasound (3DUS) at simulation compared to 3DUS at treatment is an image guidance option for partial breast irradiation (PBI). This study assessed if user dependence in acquiring and contouring 3DUS (operator variability) contributed to variation in seroma shifts calculated for breast IGRT. Eligible patients met breast criteria for current randomized PBI studies. 5 Operators participated in this study. For each patient, 3 operators were involved in scan acquisitions and 5 were involved in contouring. At CT simulation (CT1), a 3DUS (US1) was performed by a single radiation therapist (RT). 7 to 14 days after CT1 a second CT (CT2) and 3 sequential 3DUS scans (US2a,b,c) were acquired by each of 3 RTs. Seroma shifts, between US1 and US2 scans were calculated by comparing geometric centers of the seromas (centroids). Operator contouring variability was determined by comparing 5 RT’s contours for a single image set. Scanning variability was assessed by comparing shifts between multiple scans acquired at the same time point (US1-US2a,b,c). Shifts in seromas contoured on CT (CT1-CT2) were compared to US data. From an initial 28 patients, 15 had CT visible seromas, met PBI dosimetric constraints, had complete US data, and were analyzed. Operator variability contributed more to the overall variability in seroma localization than the variability associated with multiple scan acquisitions (95% confidence mean uncertainty of 6.2 mm vs. 1.1 mm). The mean standard deviation in seroma shift was user dependent and ranged from 1.7 to 2.9 mm. Mean seroma shifts from simulation to treatment were comparable to CT. Variability in shifts due to different users acquiring and contouring 3DUS for PBI guidance were comparable to CT shifts. Substantial inter-observer effect needs to be considered during clinical implementation of 3DUS IGRT

  9. Very high vitamin D supplementation rates among infants aged 2 months in Vancouver and Richmond, British Columbia, Canada

    Directory of Open Access Journals (Sweden)

    Crocker Barbara

    2011-12-01

    Full Text Available Abstract Background Vitamin D deficiency during infancy may lead to rickets and possibly other poor health outcomes. The World Health Organization recommends exclusive breastfeeding for the first 6 months. Breast milk is the best food for infants but does not contain adequate vitamin D. Health Canada recommends all breastfed infants receive a daily vitamin D supplement of 400 IU; however, there appears to be limited current Canadian data as to whether parents or caregivers are following this advice. The aim of this study was to determine the rates of vitamin D supplementation among 2-month old infants in Vancouver and Richmond, British Columbia, Canada. Methods Mothers of all healthy infants born between April and May 2010 were approached to participate. Telephone surveys were conducted with 577 mothers (response rate 56% when their infants turned 2 months. Results Over half of the infants received only breast milk in the week prior to the survey. One third received a mixture of breast milk and infant formula and 10% received only formula. About 80% of the infants were supplemented with vitamin D at 2 months. Infants who received only breast milk were most likely to be supplemented with vitamin D (91%. Over 60% of the infants had a total vitamin D intake of 300- Conclusions About 90% of the infants received breast milk at 2 months of age. The vitamin D supplementation rate was 80%. Future studies are needed to monitor breastfeeding duration and vitamin D supplementation rates as infants get older.

  10. Efficacy of Mammographic Evaluation of Breast Cancer in Women Less Than 40 Years of Age: Experience from a Single Medical Center in Taiwan

    Directory of Open Access Journals (Sweden)

    Jane Wang

    2007-09-01

    Conclusion: Mammography has an acceptable sensitivity for the detection of breast cancer in women aged less than 40 years, regardless of different breast composition. Breast ultrasound can offer a higher sensitivity for such a population.

  11. Functional, textural and sensory properties of dry pasta supplemented with lyophilized tomato matrix or with durum wheat bran extracts produced by supercritical carbon dioxide or ultrasound.

    Science.gov (United States)

    Pasqualone, Antonella; Gambacorta, Giuseppe; Summo, Carmine; Caponio, Francesco; Di Miceli, Giuseppe; Flagella, Zina; Marrese, Pier Paolo; Piro, Gabriella; Perrotta, Carla; De Bellis, Luigi; Lenucci, Marcello Salvatore

    2016-12-15

    A study was carried out to produce functional pasta by adding bran aqueous extract (BW) and bran oleoresin (BO) obtained using ultrasound and supercritical CO2, respectively, or a powdery lyophilized tomato matrix (LT). The bioactive compounds, hydrophilic and lipophilic antioxidant activity (HAA and LAA) in vitro, were evaluated. BW supplementation did not improve antioxidant activity, whilst LT pasta showed unconventional taste and odor. BO pasta had good levels of tocochromanols (2551μg/100g pasta f.w.) and carotenoids (40.2μg/100g pasta f.w.), and the highest HAA and LAA. The oleoresin altered starch swelling and gluten network, as evidenced by scanning electron microscopy, therefore BO pasta had structural characteristics poor compared with the control (4.8% vs. 3.2% cooking loss), although this difference did not affect significantly overall sensory judgment (74 vs. 79 for BO and control, respectively). BO supplementation was most effective for increasing antioxidant activity without jeopardizing pasta quality. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Preoperative axillary lymph node staging by ultrasound-guided cytology using a four-level sonographic score

    International Nuclear Information System (INIS)

    De Coninck, Caroline; Noël, Jean-Christophe; Boutemy, Rachel; Simon, Philippe

    2016-01-01

    The staging of axillary lymph nodes is critical to the management and prognosis of breast cancer, the most frequent cancer in females. Neoadjuvant therapy and lymph node dissection are recommended when malignant cells invade the lymph nodes. Therefore the pre-operative examination of these lymph nodes is crucial to treatment. In this study, we examined the effectiveness of cytology through ultrasound-guided fine needle aspiration (USG-FNA) and ultrasound (US) imaging using an established classification system in correctly identifying lymph node status compared to the final histological results after surgery. Cytology by USG-FNA and US classification were found to be promising methods of axillary lymph node staging. US and CB offer minimally invasive techniques to pre-operatively examine these lymph nodes in patients with primary breast cancer

  13. Computer-Aided Diagnosis of Solid Breast Lesions Using an Ultrasonic Multi-Feature Analysis Procedure

    Science.gov (United States)

    2011-01-01

    ultrasound. 1. BACKGROUND AND INTRODUCTION Breast cancer affects one of every eight women, it kills one of 29 women in the United States, and is the leading...feature analysis procedure for computer-aided diagnosis of solid breast lesions,” Ultrason Imag, 2010 (In Press). 22. C. B. Shakespeare , personal

  14. An introduction to microwave imaging for breast cancer detection

    CERN Document Server

    Conceição, Raquel Cruz; O'Halloran, Martin

    2016-01-01

    This book collates past and current research on one of the most promising emerging modalities for breast cancer detection. Readers will discover how, as a standalone technology or in conjunction with another modality, microwave imaging has the potential to provide reliable, safe and comfortable breast exams at low cost. Current breast imaging modalities include X- ray, Ultrasound, Magnetic Resonance Imaging, and Positron Emission Tomography. Each of these methods suffers from limitations, including poor sensitivity or specificity, high cost, patient discomfort, and exposure to potentially harmful ionising radiation. Microwave breast imaging is based on a contrast in the dielectric properties of breast tissue that exists at microwave frequencies. The book begins by considering the anatomy and dielectric properties of the breast, contrasting historical and recent studies. Next, radar-based breast imaging algorithms are discussed, encompassing both early-stage artefact removal, and data independent and adaptive ...

  15. SU-E-J-76: Incorporation of Ultrasound Elastography in Target Volume Delineation for Partial Breast Radiotherapy Planning: A Comparative Study

    Energy Technology Data Exchange (ETDEWEB)

    Juneja, P; Harris, E; Bamber, J [The Institute of Cancer Research, London (United Kingdom); Royal Marsden NHS Foundation Trust, London (United Kingdom)

    2014-06-01

    Purpose: There is substantial observer variability in the delineation of target volumes for post-surgical partial breast radiotherapy because the tumour bed has poor x-ray contrast. This variability may result in substantial variations in planned dose distribution. Ultrasound elastography (USE) has an ability to detect mechanical discontinuities and therefore, the potential to image the scar and distortion in breast tissue architecture. The goal of this study was to compare USE techniques: strain elastography (SE), shear wave elastography (SWE) and acoustic radiation force impulse (ARFI) imaging using phantoms that simulate features of the tumour bed, for the purpose of incorporating USE in breast radiotherapy planning. Methods: Three gelatine-based phantoms (10% w/v) containing: a stiff inclusion (gelatine 16% w/v) with adhered boundaries, a stiff inclusion (gelatine 16% w/v) with mobile boundaries and fluid cavity inclusion (to mimic seroma), were constructed and used to investigate the USE techniques. The accuracy of the elastography techniques was quantified by comparing the imaged inclusion with the modelled ground-truth using the Dice similarity coefficient (DSC). For two regions of interest (ROI), the DSC measures their spatial overlap. Ground-truth ROIs were modelled using geometrical measurements from B-mode images. Results: The phantoms simulating stiff scar tissue with adhered and mobile boundaries and seroma were successfully developed and imaged using SE and SWE. The edges of the stiff inclusions were more clearly visible in SE than in SWE. Subsequently, for all these phantoms the measured DSCs were found to be higher for SE (DSCs: 0.91–0.97) than SWE (DSCs: 0.68–0.79) with an average relative difference of 23%. In the case of seroma phantom, DSC values for SE and SWE were similar. Conclusion: This study presents a first attempt to identify the most suitable elastography technique for use in breast radiotherapy planning. Further analysis will

  16. SU-E-J-76: Incorporation of Ultrasound Elastography in Target Volume Delineation for Partial Breast Radiotherapy Planning: A Comparative Study

    International Nuclear Information System (INIS)

    Juneja, P; Harris, E; Bamber, J

    2014-01-01

    Purpose: There is substantial observer variability in the delineation of target volumes for post-surgical partial breast radiotherapy because the tumour bed has poor x-ray contrast. This variability may result in substantial variations in planned dose distribution. Ultrasound elastography (USE) has an ability to detect mechanical discontinuities and therefore, the potential to image the scar and distortion in breast tissue architecture. The goal of this study was to compare USE techniques: strain elastography (SE), shear wave elastography (SWE) and acoustic radiation force impulse (ARFI) imaging using phantoms that simulate features of the tumour bed, for the purpose of incorporating USE in breast radiotherapy planning. Methods: Three gelatine-based phantoms (10% w/v) containing: a stiff inclusion (gelatine 16% w/v) with adhered boundaries, a stiff inclusion (gelatine 16% w/v) with mobile boundaries and fluid cavity inclusion (to mimic seroma), were constructed and used to investigate the USE techniques. The accuracy of the elastography techniques was quantified by comparing the imaged inclusion with the modelled ground-truth using the Dice similarity coefficient (DSC). For two regions of interest (ROI), the DSC measures their spatial overlap. Ground-truth ROIs were modelled using geometrical measurements from B-mode images. Results: The phantoms simulating stiff scar tissue with adhered and mobile boundaries and seroma were successfully developed and imaged using SE and SWE. The edges of the stiff inclusions were more clearly visible in SE than in SWE. Subsequently, for all these phantoms the measured DSCs were found to be higher for SE (DSCs: 0.91–0.97) than SWE (DSCs: 0.68–0.79) with an average relative difference of 23%. In the case of seroma phantom, DSC values for SE and SWE were similar. Conclusion: This study presents a first attempt to identify the most suitable elastography technique for use in breast radiotherapy planning. Further analysis will

  17. Male breast cancer

    International Nuclear Information System (INIS)

    Ferrando, F.; Vidal, M.A.; Caballero, A.J.; Martinez, A.; Lluch, A.

    1997-01-01

    To analyze the radiological and ultrasonographic signs that contribute to the diagnosis of male breast cancer to establish its differential diagnosis with regard to the most common pathologies involving the male breast. We studied 14 patients diagnosed as heaving breast cancer over the past 23 years. We reviewed their medical records, personal and familial history disease, use of pharmacological agents and the mammographic and ultrasonographic findings. The literature on this subject was also reviewed. Given the fact that his lesion is rare and unexpected in men, a large percentage of the cases, especially those studied in the early years of the study period, involved very advanced stages of the disease at diagnosis. The most common clinical finding was retroarelar mass. Mammography usually reveals a well.defined mass and ultrasound shows a well-defined, hypoechoic, heterogeneous mass. The most frequent histological type is, an in women, the infiltrating ductal carcinoma. A palpable breast mass in a man should suggest possible malignant disease. Thus, mammographic and ultrasonographic studies should be performed early, accompanied, if necessary, by aspiration biopsy; with these measures the prognosis may approximate that of women. (Author) 21 refs

  18. Breast Abscessed Cancer in Nonlactating Women in Tropical Environment: Radiological, Bacteriological, and Anatomopathological Features about 3 Cases

    Directory of Open Access Journals (Sweden)

    Mazamaesso Tchaou

    2017-01-01

    Full Text Available The association of breast cancer and abscess is rare in daily practice. The authors report a short series of 3 cases of cancer of the breast in nonlactating women presented as breast abscess, reviewing aspects in radiology (ultrasound and mammography, correlating them with the histopathology findings and the bacteriological profile of the isolated germs.

  19. Invasive ductal carcinoma of the breast in a 14-year-old girl

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joo Yeon; Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo [Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Department of Radiology, Seoul (Korea, Republic of); Song, Byung Joo [The Catholic University of Korea, Department of General Surgery, Seoul St. Mary' s Hospital, College of Medicine, Seoul (Korea, Republic of)

    2014-11-15

    Breast cancer is rare in children and adolescents. In particular, there are very few cases of invasive ductal carcinoma in childhood. We report a case of invasive ductal carcinoma of the breast in a 14-year-old girl presenting as a palpable mass. While the tumor demonstrated a relatively benign appearance on ultrasound, magnetic resonance imaging revealed typical malignant features. Several polymorphisms of single nucleotide variation were observed on gene analysis. The patient underwent breast conserving surgery and received subsequent concurrent chemo-radiation therapy. An awareness that ductal carcinoma of the breast rarely occurs in children is important to detect early stage breast cancer. (orig.)

  20. Progress in diagnosis of breast cancer: Advances in radiology technology

    Directory of Open Access Journals (Sweden)

    J Mari Beth Linder

    2015-01-01

    Full Text Available Breast cancer is the leading cause of cancer in females between the ages of 15 and 54, and the second leading cause of cancer death in women in the United States. Diagnosis begins with detection by breast examination (clinical breast exam or breast self-exam or by radiologic studies, like mammography. Many advances in the diagnosis of breast cancer have taken place in recent years. This article will review the history of radiologic advances in the diagnosis of breast cancer. Use of technological advancements in digital breast tomosynthesis, magnetic resonance imaging, and ultrasound in breast cancer diagnosis will be presented. Advantages and disadvantages of these diagnostic interventions when compared to older, traditional X-ray films will be discussed. It is important for all nurses, including radiology and oncology nurses, to be well informed about these varied diagnostic modalities, and appreciate the fact that advances in radiologic imaging technologies can yield improved outcomes for breast cancer patients.