WorldWideScience

Sample records for suction

  1. Tissue holding device for use during surgical procedure, has contact body with suction foot and suction mouth that is surrounded by rim, and suction pipe connected to suction chamber

    OpenAIRE

    Vonck, D.; Goossens, R.H.M.; Flipsen, S.F.J.; Jakimowicz, J.J.; Van der Putten, E.P.W.

    2009-01-01

    The device has a locking ring (5), a connector (6), and a contact body (1) with a suction foot and a suction mouth (8), where the mouth is surrounded by a rim (10), which is substantially located in a plane of the suction foot. A suction chamber (9) has a sieve-shaped inner wall (2) and a transparent side wall, and a suction pipe (11) is connected to the chamber.

  2. Hydroponic Feed With Suction

    Science.gov (United States)

    Cox, William M.; Brown, Christopher S.; Dreschel, Thomas W.

    1994-01-01

    Placing nutrient solution under suction increases growth. Foam plug seals growing stem of plant, making it possible to maintain suction in nutrient liquid around roots. Jar wrapped in black tape to keep out light. Potential use in terrestrial applications in arid climates or in labor-intensive agricultural situations.

  3. Dynamic stiffness of suction caissons

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten; Andersen, Lars

    The purpose of this report is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigation is limited to a determination of the vertical dynamic stiffness of suction caissons. The soil surrounding the foundation is homogenous with linear...... viscoelastic properties. The dynamic stiffness of the suction caisson is expressed by dimensionless frequency-dependent dynamic stiffness coefficients corresponding to the vertical degree of freedom. The dynamic stiffness coefficients for the foundations are evaluated by means of a dynamic three...

  4. Suction is kid's play: extremely fast suction in newborn seahorses

    Science.gov (United States)

    Van Wassenbergh, Sam; Roos, Gert; Genbrugge, Annelies; Leysen, Heleen; Aerts, Peter; Adriaens, Dominique; Herrel, Anthony

    2009-01-01

    Ongoing anatomical development typically results in a gradual maturation of the feeding movements from larval to adult fishes. Adult seahorses are known to capture prey by rotating their long-snouted head extremely quickly towards prey, followed by powerful suction. This type of suction is powered by elastic recoil and requires very precise coordination of the movements of the associated feeding structures, making it an all-or-none phenomenon. Here, we show that newborn Hippocampus reidi are able to successfully feed using an extremely rapid and powerful snout rotation combined with a high-volume suction, surpassing that observed in adult seahorses. An inverse dynamic analysis shows that an elastic recoil mechanism is also used to power head rotation in newborn H. reidi. This illustrates how extreme levels of performance in highly complex musculoskeletal systems can be present at birth given a delayed birth and rapid development of functionally important structures. The fact that the head skeleton of newborn seahorses is still largely cartilaginous may not be problematic because the hydrodynamic stress on the rotating snout appeared considerably lower than in adult syngnathids. PMID:19324657

  5. PERBEDAAN PARAMETER KARDIOPULMONAL SETELAH TINDAKAN OPEN SUCTION

    Directory of Open Access Journals (Sweden)

    Muhamat Nofiyanto

    2013-12-01

    Full Text Available Background: Endotracheal suctioning is often performed by nurses and beneficial for critically ill patients. Suctioning is essential for removing secretions, maintaining airway patency and prevent unexpected complications. Open suctioning is performed by disconnecting patients with the ventilator. Suctioning not only removed secretions in the airway but also oxygen. Suctioning must be done correctly, safely, effectively and efficiently to prevent unexpected events in critically ill patients. Objective: This study aimed to determine differences on cardiopulmonary parameters after open suction in critically ill patients Methods: The study design was comparatif cross sectional analytic approach, using one group pre test and post test. The sample of the research amounted to 34 people, using purposive sampling technique. Catheter size 14 Fr on ETT number 7 mm used in this research to performed endotracheal suctioning. Cardiopulmonary parameters (Heart rate/ HR, respiratory rate/RR, oxygen saturation/SpO2, systolic blood pressure/ SBP and diastolic blood pressure/DBP measured by pulse oxymeter and bedside monitor before suction and immediately thereafter. Results: The results showed increase average heart rate 6.412 (from 106.62 into 113.03, Respiratory rate has increased 4.971 (from 20.62 into 25.59, SpO2 decreased 1.68 (from 99.09 into 97.41, and systolic blood pressure increased 5.71 (from 118.29 into 124.00 after performed open suction. The results of paired t-test statistical analysis (for RR, HR obtained a < 0.05 (0.000, whereas Wilcoxon statistical analysis (for SpO2, SBP obtained a < 0.05 (0.000 and 0.001. So it can be said that the difference cardiopulmonary parameters was statistically significant after perfomed open suction in critically ill patients.

  6. Suction caissons subjected to monotonic combined loading

    DEFF Research Database (Denmark)

    Penzes, P.; Jensen, M.R.; Zania, Varvara

    2016-01-01

    Suction caissons are being increasingly used as offshore foundation solutions in shallow and intermediate water depths. The convenient installation method through the application of suction has rendered this type of foundation as an attractive alternative to the more traditional monopile foundation...... for offshore wind turbines. The combined loading imposed typically to a suction caisson has led to the estimation of their bearing capacity by means of 3D failure envelopes. This study aims to analyse the behaviour of suction caissons for offshore wind turbines subjected to combined loading. Finite element...

  7. Scaled multiple holes suction tip for microneurosurgery; Technical note

    Directory of Open Access Journals (Sweden)

    Abdolkarim Rahmanian, Associate Professor of Neurosurgery

    2017-12-01

    Conclusion: The new suction tip permits easy and precise adjustment of suction power in microneurosirgical operations. Our scaled 3 and 4-hole suction tip is a simple and useful device for controlling the suction power during the microneurosurgeical procedures.

  8. Evaluation of hypopharyngeal suction to eliminate aspiration: the Retro-Esophageal Suction (REScue) catheter.

    Science.gov (United States)

    Belafsky, Peter C; Mehdizadeh, O B; Ledgerwood, L; Kuhn, M

    2015-02-01

    Profound oropharyngeal dysphagia (OPD) is common and costly. Treatment options are limited. The purpose of this investigation was to evaluate the utility of hypopharyngeal suction at the upper esophageal sphincter (UES) to eliminate aspiration. Five different catheters were passed retrograde up the esophagus and positioned at the UES in a cadaver model of profound OPD. Suction was affixed to each catheter. 10 cc of barium was administered into the pyriform sinus, and videofluoroscopy was utilized to evaluate the presence of aspiration. 6 trials were administered per catheter and for a no catheter control. The outcome measures were the incidence of aspiration, the NIH Swallow Safety Scale (NIH-SSS), and UES opening. Control trials with no suction resulted in an aspiration rate of 100 % (6/6 trials). Negative pressure through 16, 18, 24, and 30 Fr catheter resulted in an aspiration rate of 0 % (0/24 trials; p  0.05). The mean NIH-SSS improved from 7.0 (±0.0) in the control to 0 (±0.0) with hypopharyngeal suction (18 Fr nasogastric catheter; p 12 Fr) at the level of the UES reduced aspiration by 100 % and significantly increased UES opening in a cadaveric model of profound oropharyngeal dysphagia.

  9. Dynamic lateral response of suction caissons

    DEFF Research Database (Denmark)

    Latini, Chiara; Zania, Varvara

    2017-01-01

    Deeper water installations of offshore wind turbines may be supported by jacket structures. This study investigates the dynamic response of suction caissons for jackets by analysing 3D finite element models in the frequency domain. The numerical modelling was firstly validated by analytical...... solutions for pile foundations. Groups of crucial dimensionless parameters related to the soil profile and the foundation geometry are identified and their effects on the response of suction caissons are studied. Static stiffness coefficients are presented in a form of mathematical formulas obtained...... by fitting the numerical results, pertaining foundations with different slenderness ratios and embedded in different soil profiles. Sensitivity of the dynamic impedances of suction caissons on the skirt length was showed in this study. Moreover, the results for the suction caissons indicated that the overall...

  10. Place Atrium to Water Seal (PAWS): Assessing Wall Suction Versus No Suction for Chest Tubes After Open Heart Surgery.

    Science.gov (United States)

    Kruse, Tamara; Wahl, Sharon; Guthrie, Patricia Finch; Sendelbach, Sue

    2017-08-01

    Traditionally chest tubes are set to -20 cm H 2 O wall suctioning until removal to facilitate drainage of blood, fluid, and air from the pleural or mediastinal space in patients after open heart surgery. However, no clear evidence supports using wall suction in these patients. Some studies in patients after pulmonary surgery indicate that using chest tubes with a water seal is safer, because this practice decreases duration of chest tube placement and eliminates air leaks. To show that changing chest tubes to a water seal after 12 hours of wall suction (intervention) is a safe alternative to using chest tubes with wall suction until removal of the tubes (usual care) in patients after open heart surgery. A before-and-after quality improvement design was used to evaluate the differences between the 2 chest tube management approaches in chest tube complications, output, and duration of placement. A total of 48 patients received the intervention; 52 received usual care. The 2 groups (intervention vs usual care) did not differ significantly in complications (0 vs 2 events; P = .23), chest tube output (H 1 = 0.001, P = .97), or duration of placement (median, 47 hours for both groups). Changing chest tubes from wall suction to water seal after 12 hours of wall suction is a safe alternative to using wall suctioning until removal of the tubes. ©2017 American Association of Critical-Care Nurses.

  11. Suction caissons subjected to monotonic combined loading

    OpenAIRE

    Penzes, P.; Jensen, M.R.; Zania, Varvara

    2016-01-01

    Suction caissons are being increasingly used as offshore foundation solutions in shallow and intermediate water depths. The convenient installation method through the application of suction has rendered this type of foundation as an attractive alternative to the more traditional monopile foundation for offshore wind turbines. The combined loading imposed typically to a suction caisson has led to the estimation of their bearing capacity by means of 3D failure envelopes. This study aims to anal...

  12. Boundary layer on a flat plate with suction

    International Nuclear Information System (INIS)

    Favre, A.; Dumas, R.; Verollet, E.

    1961-01-01

    This research done in wind tunnel concerns the turbulent boundary layer of a porous flat plate with suction. The porous wall is 1 m long and begins 1 m downstream of the leading edge. The Reynolds number based on the boundary layer thickness is of the order of 16.300. The suction rate defined as the ratio of the velocity perpendicular to the wall to the external flow velocity ranges from 0 to 2 per cent. The pressure gradient can be controlled. The mean velocity profiles have been determined for various positions and suction rates by means of total pressure probes together with the intensities of the turbulent velocity fluctuations components, energy spectra and correlations by means of hot wire anemometers, spectral analyser and correlator. The stream lines, the values of the viscous and turbulent shear stresses, of the local wall friction, of the turbulent energy production term, with some information on the dissipation of the energy have been derived from these measurements. For these data the integral of equation of continuity in boundary layer have been drawn. The suction effects on the boundary layer are important. The suction thoroughly alters the mean velocity profiles by increasing the viscous shear stresses near the wall and decreasing them far from the wall, it diminishes the longitudinal and transversal turbulence intensities, the turbulent shear stresses, and the production of energy of turbulence. These effects are much stressed in the inner part of the boundary layer. On the other hand the energy spectra show that the turbulence scale is little modified, the boundary layer thickness being not much diminished by the suction. The suction effects can be appreciated by comparing twice the suction rate to the wall friction coefficient (assumed airtight), quite noticeable as soon as the rate is about unity, they become very important when it reaches ten. (author) [fr

  13. Overcoming the problem of residual microbial contamination in dental suction units left by conventional disinfection using novel single component suction handpieces in combination with automated flood disinfection.

    Science.gov (United States)

    Boyle, M A; O'Donnell, M J; Russell, R J; Galvin, N; Swan, J; Coleman, D C

    2015-10-01

    Decontaminating dental chair unit (DCU) suction systems in a convenient, safe and effective manner is problematic. This study aimed to identify and quantify the extent of the problems using 25 DCUs, methodically eliminate these problems and develop an efficient approach for reliable, effective, automated disinfection. DCU suction system residual contamination by environmental and human-derived bacteria was evaluated by microbiological culture following standard aspiration disinfection with a quaternary ammonium disinfectant or alternatively, a novel flooding approach to disinfection. Disinfection of multicomponent suction handpieces, assembled and disassembled, was also studied. A prototype manual and a novel automated Suction Tube Cleaning System (STCS) were developed and tested, as were novel single component suction handpieces. Standard aspiration disinfection consistently failed to decontaminate DCU suction systems effectively. Semi-confluent bacterial growth (101-500 colony forming units (CFU) per culture plate) was recovered from up to 60% of suction filter housings and from up to 19% of high and 37% of low volume suction hoses. Manual and automated flood disinfection of DCU suction systems reduced this dramatically (ranges for filter cage and high and low volume hoses of 0-22, 0-16 and 0-14CFU/plate, respectively) (P<0.0001). Multicomponent suction handpieces could not be adequately disinfected without prior removal and disassembly. Novel single component handpieces, allowed their effective disinfection in situ using the STCS, which virtually eliminated contamination from the entire suction system. Flood disinfection of DCU suction systems and single component handpieces radically improves disinfection efficacy and considerably reduces potential cross-infection and cross-contamination risks. DCU suction systems become heavily contaminated during use. Conventional disinfection does not adequately control this. Furthermore, multicomponent suction handpieces

  14. Suction power output and the inertial cost of rotating the neurocranium to generate suction in fish.

    Science.gov (United States)

    Van Wassenbergh, Sam; Day, Steven W; Hernández, L Patricia; Higham, Timothy E; Skorczewski, Tyler

    2015-05-07

    To expand the buccal cavity, many suction-feeding fishes rely on a considerable contribution from dorsal rotation of the dorsal part of the head including the brains, eyes, and several bones forming the braincase and skull roof (jointly referred to as the neurocranium). As the neurocranium takes up a large part of the total mass of the head, this rotation may incur a considerable inertial cost. If so, this would suggest a significant selective pressure on the kinematics and mass distribution of the neurocranium of suction feeders. Here, an inverse dynamic model is formulated to calculate the instantaneous power required to rotate the neurocranium, approximated by a quarter ellipsoid volume of homogeneous density, as well as to calculate the instantaneous suction power based on intra-oral pressure and head volume quantifications. We applied this model to largemouth bass (Micropterus salmoides) and found that the power required to rotate the neurocranium accounts for only about 4% of the power required to suck water into the mouth. Furthermore, recovery of kinetic energy from the rotating neurocranium converted into suction work may be possible during the phase of neurocranial deceleration. Thus, we suggest that only a negligible proportion of the power output of the feeding muscles is lost as inertial costs in the largemouth bass. Consequently, the feeding performance of piscivorous suction feeders with generalised morphology, comparable to our model species, is not limited by neurocranial motion during head expansion. This suggests that it is thus not likely to be a factor of importance in the evolution of cranial shape and size. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Suction v. conventional curettage in incomplete abortion

    African Journals Online (AJOL)

    Suction v. conventional curettage in incomplete abortion. A randomised controlled trial. D. A. A. VERKUYL, C. A. CROWTHER .Abstract This randomised controlled trial of 357 patients who had had an incomplete abortion compared suction curettage with conventional curettage for evacuation ofthe uterus. The 179 patients ...

  16. Dielectric elastomer actuators for octopus inspired suction cups.

    Science.gov (United States)

    Follador, M; Tramacere, F; Mazzolai, B

    2014-09-25

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms.

  17. Dielectric elastomer actuators for octopus inspired suction cups

    International Nuclear Information System (INIS)

    Follador, M; Tramacere, F; Mazzolai, B

    2014-01-01

    Suction cups are often found in nature as attachment strategy in water. Nevertheless, the application of the artificial counterpart is limited by the dimension of the actuators and their usability in wet conditions. A novel design for the development of a suction cup inspired by octopus suckers is presented. The main focus of this research was on the modelling and characterization of the actuation unit, and a first prototype of the suction cup was realized as a proof of concept. The actuation of the suction cup is based on dielectric elastomer actuators. The presented device works in a wet environment, has an integrated actuation system, and is soft. The dimensions of the artificial suction cups are comparable to proximal octopus suckers, and the attachment mechanism is similar to the biological counterpart. The design approach proposed for the actuator allows the definition of the parameters for its development and for obtaining a desired pressure in water. The fabricated actuator is able to produce up to 6 kPa of pressure in water, reaching the maximum pressure in less than 300 ms. (paper)

  18. Does the suction drain diameter matter? Bleeding analysis after total knee replacement comparing different suction drain gauges

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leao

    Full Text Available ABSTRACT OBJECTIVES: To evaluate bleeding and the estimated blood loss in patients who underwent total knee replacement (TKR with different closed suction drains (3.2-mm and 4.8-mm gauge. METHODS: This was a randomized controlled trial with 22 patients who underwent TKR and were divided into two groups: Group I, with 11 patients in whom the 3.2-mm suction drain was used, and Group II, with 11 patients in whom the 4.8-mm suction drain was used. The hematocrit was measured after 24, 48 and 72 h after surgery in order to calculate the estimated blood loss. The drained volume was measured 3, 6, 12, 24, and 48 h after TKR, and thereafter both groups were compared. RESULTS: Regarding the hematocrit, there were no differences between groups in measured periods (24, 48, and 72 h after surgery. The total bleeding measured at the suction drains within 48 h was higher in Group II, with a statistically significant difference (p = 0.005; in the first 24 h, there was major bleeding in Group II (mean 893 mL, with a significant difference (p = 0.004. Between 24 and 48 h, there was no statistically significant difference in both groups (p = 0.710. The total estimated bleeding was higher in Group I, with mean of 463 mL, versus 409 mL in Group II, with no statistical significance (p = 0.394. CONCLUSIONS: Bleeding was higher in the group that used the 4.8 mm gauge suction drain, with no differences in hematocrit and estimated blood loss.

  19. Advances on development of suction and temperature controlled oedometer cell

    International Nuclear Information System (INIS)

    Ye Weimin; Zhang Yawei; Chen Bao; Wang Min

    2010-01-01

    Oedometer cells for unsaturated soils can be classified into two types, that is, conventional unsaturated oedometer cells (high-suction unsaturated oedometer cell, high-suction and high-pressure unsaturated oedometer cell) and temperature controlled unsaturated oedometer cells. Among them, the osmotic, vapor equilibrium and axis translation techniques are often employed for suction control. The thermostat bath method and thermostatically controlled heater method are commonly used for temperature control. The lever loading system, hydraulic loading system and air pressure loading system are commonly means used for vertical pressure. Combination of osmotic (or axis translation) technique with vapor equilibrium method employed for the full range suction control, thermostatically liquid temperature control method, and the hydraulic loading system, could be used for suction, temperature and loading control in the design for unsaturated oedometer cells in the future, which can be used for study of buffer/backfill materials under high-temperature, high pressure and full range suction conditions. (authors)

  20. Dynamic Behaviour of Suction Caissons

    DEFF Research Database (Denmark)

    Liingaard, Morten

    to the excitation frequencies of the rotor system, it is of outmost importance to be able to evaluate the resonance frequencies of the wind turbine structure accurately as the wind turbines increase in size. In order to achieve reliable responses of the wind turbine structure during working loads it is necessary...... in a composite structure-foundation system. The work has been focused on one particular foundation type; the suction caisson. The frequency dependent stiffness (impedance) of the suction caisson has been investigated by means of a three-dimensional coupled Boundary Element/Finite Element model, where the soil...

  1. Investigation of suction anchor pullout capacity under undrained conditions

    OpenAIRE

    Jarand, Pollestad

    2015-01-01

    Master's thesis in Offshore technology Floating units are dependent on reliable mooring systems to ensure safety during marine operations. Suction anchors have proved to be a technologically viable and cost-effective concept. They are capable of precision installation, re-use, and provide large resistive capacity. This thesis investigates load capacity and failure modes of suction anchors subjected to vertical, horizontal (lateral), and incline loading. Suction anchor design co...

  2. Enhanced effect of suction-cavitation on the ozonation of phenol

    International Nuclear Information System (INIS)

    Wu Zhilin; Franke, Marcus; Ondruschka, Bernd; Zhang, Yongchun; Ren Yanze; Braeutigam, Patrick; Wang, Weimin

    2011-01-01

    800 mL of 1.0 mM phenol-containing aqueous solution was circulated at 20 ° C for 30 min in a suction-reactor, while 3.2 mg min -1 ozone was introduced into the solution under the suction orifice. The removal rates of phenol vary polynomially with the orifice diameter as well as the suction pressure. The rate constant for the zero-order kinetics achieves the highest value at -0.070 MPa by using 5 mm orifice. Although the suction-cavitation alone cannot remove phenol in 30 min, it can considerably enhance the ozonation of phenol. The rate constants for the zero-order kinetics by the simple ozonation and the combined method are 0.018 and 0.028 min -1 , respectively. Furthermore, no ozone was observed in the tail gas during the first 15 min for the ozonation in the suction reactor, and then the concentration of unreacted ozone slowly increased, indicating that the utilization rate of ozone is significantly improved by the suction-cavitation. The increasing input concentration of ozone obviously accelerates the ozonation of phenol, but the total required quantities of ozone are very close by various ozone input concentrations to reach the same degradation rate, indicating the ozonation assisted by the suction-cavitation can be considered as a quantitative reaction.

  3. Numerical simulation and experimental investigation on suction heating of a BOG compressor

    International Nuclear Information System (INIS)

    Jia, Xiaohan; Zhao, Bin; Feng, Jianmei; Zheng, Sulu; Peng, Xueyuan

    2016-01-01

    Highlights: • An investigation focusing on suction heating of a BOG compressor is carried out. • There is frost on the cylinder cover as the compressor at lower suction temperature. • The suction and discharge flow rate decrease with rising suction temperature. • The volumetric efficiency has a maximum value with increasing suction temperature. • The temperature coefficient increased with suction temperature or rotational speed. - Abstract: One of the key components of a liquefied natural gas (LNG) receiving terminal is the boil-off gas (BOG) compressor, which is used to pump out the BOG from the LNG storage tank to ensure safety in the transportation and receiving systems. Owing to the ultra-low suction temperature, the heat exchange between the intake gas and the cylinder, piston, and cylinder cover cannot be ignored as in normal conditions. This paper presents an investigation focusing on suction heating of the BOG compressor. A finite element model with dynamic mesh was established to simulate the suction process. At the same time, a performance test rig was built to study the characteristics of the BOG compressor under low suction temperature conditions and verify the numerical model. Consequently, the results of the simulation were in good agreement with experimental results. Both results implied that the temperature of cylinder surface increased starting from the cylinder cover to the crankcase. In addition, at lower suction temperature, the temperature difference between various points on the cylinder surface and cylinder cover was much larger than that at higher suction temperature. With increasing suction temperature, the temperature coefficient increased markedly, and the difference between gas temperatures at the beginning and end of the suction process, as well as the compressor flow rate, decreased significantly; however, the volumetric efficiency increased first and then decreased. Furthermore, the temperature coefficient clearly increased

  4. On equations for the total suction and its matric and osmotic components

    International Nuclear Information System (INIS)

    Dao, Vinh N.T.; Morris, Peter H.; Dux, Peter F.

    2008-01-01

    A clear fundamental understanding of suctions is crucial for the study of the behaviour of plastic cement mortar and concrete, including plastic shrinkage cracking. In this paper, the expression relating the change in free energy of the pore water with an isothermal change in pressure is first derived. Based upon definitions of suctions, it is then shown that total, matric, and osmotic suctions can all be expressed in the same thermodynamic form. The widely accepted, but not yet satisfactorily validated, assumption that the total suction comprises matric and osmotic components is then confirmed theoretically. The well-known Kelvin equation for matric suction, and Morse and van't Hoff equations for osmotic suction are subsequently derived from the corresponding thermodynamic equations. The applicability of latter two equations in evaluating the osmotic suctions of cement mortar and concrete is highlighted

  5. Suction v. conventional curettage in incomplete abortion A ...

    African Journals Online (AJOL)

    This randomised controlled trial of 357 patients who had had an incomplete abortion compared suction curettage with conventional curettage for evacuation ofthe uterus. The 179 patients undergoing suction curettage had a significantly lower intra-operative blood loss (P < 0,0001) and a significantly higher mean ...

  6. Octopus-like suction cups: from natural to artificial solutions.

    Science.gov (United States)

    Tramacere, F; Follador, M; Pugno, N M; Mazzolai, B

    2015-05-13

    Octopus suckers are able to attach to all nonporous surfaces and generate a very strong attachment force. The well-known attachment features of this animal result from the softness of the sucker tissues and the surface morphology of the portion of the sucker that is in contact with objects or substrates. Unlike artificial suction cups, octopus suckers are characterized by a series of radial grooves that increase the area subjected to pressure reduction during attachment. In this study, we constructed artificial suction cups with different surface geometries and tested their attachment performances using a pull-off setup. First, smooth suction cups were obtained for casting; then, sucker surfaces were engraved with a laser cutter. As expected, for all the tested cases, the engraving treatment enhanced the attachment performance of the elastomeric suction cups compared with that of the smooth versions. Moreover, the results indicated that the surface geometry with the best attachment performance was the geometry most similar to octopus sucker morphology. The results obtained in this work can be utilized to design artificial suction cups with higher wet attachment performance.

  7. Comparison the Effects of Shallow and Deep Endotracheal Tube Suctioning on Respiratory Rate, Arterial Blood Oxygen Saturation and Number of Suctioning in Patients Hospitalized in the Intensive Care Unit: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasinia

    2014-09-01

    Full Text Available Introduction: Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR, arterial blood oxygen saturation (SpO2 and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. Methods: In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA, chi-square and independent t-tests. Results: RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion: Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient’s trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  8. Comparison the effects of shallow and deep endotracheal tube suctioning on respiratory rate, arterial blood oxygen saturation and number of suctioning in patients hospitalized in the intensive care unit: a randomized controlled trial.

    Science.gov (United States)

    Abbasinia, Mohammad; Irajpour, Alireza; Babaii, Atye; Shamali, Mehdi; Vahdatnezhad, Jahanbakhsh

    2014-09-01

    Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR), arterial blood oxygen saturation (SpO2) and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA), chi-square and independent t-tests. RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion : Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  9. Development of standard practice guidelines for open and closed system suctioning.

    Science.gov (United States)

    Özden, Dilek; Görgülü, R Selma

    2012-05-01

    This study was carried out to determine the knowledge and practice of nurses before and after training and the development of standard practice guidelines for open and closed system suctioning methods in patients with endotracheal tubes. Many life-threatening complications can occur when a suctioning procedure is not performed with the correct technique. It has been reported that standard practice guidelines for suctioning are insufficient in clinical practice. Non-participant structured observational study. We assessed a total of 48 nurses who were employed in the cardiovascular surgery intensive care unit of a state hospital in Turkey. We used a questionnaire and nurse observation forms to assess the use of the open and closed system suctioning. There was a significant difference between the mean scores of the answers ('true', 'wrong' and 'I do not know') for the use of open and closed system suctioning before and after training. In addition, all steps of both suctioning procedures were carried out correctly during the third observation. The compliance of the nurses to the standard practice guidelines for open and closed suctioning and their knowledge levels on the subject were increased after training, while the implementation of standards was satisfactory. The development of open and closed system suctioning standard practice guidelines directly contributed to the enhancement of patient safety and the quality of nursing care. It is suggested that, as in other nursing care practices, suctioning should be carried out in accordance with standard practice guidelines, and health institutions should develop their standard practice guidelines and work in accordance with them. © 2012 Blackwell Publishing Ltd.

  10. Suction generation in white-spotted bamboo sharks Chiloscyllium plagiosum.

    Science.gov (United States)

    Wilga, Cheryl D; Sanford, Christopher P

    2008-10-01

    After the divergence of chondrichthyans and teleostomes, the structure of the feeding apparatus also diverged leading to alterations in the suction mechanism. In this study we investigated the mechanism for suction generation during feeding in white-spotted bamboo sharks, Chiloscyllium plagiosum and compared it with that in teleosts. The internal movement of cranial elements and pressure in the buccal, hyoid and pharyngeal cavities that are directly responsible for suction generation was quantified using sonomicrometry and pressure transducers. Backward stepwise multiple linear regressions were used to explore the relationship between expansion and pressure, accounting for 60-96% of the variation in pressure among capture events. The progression of anterior to posterior expansion in the buccal, hyoid and pharyngeal cavities is accompanied by the sequential onset of subambient pressure in these cavities as prey is drawn into the mouth. Gape opening triggers the onset of subambient pressure in the oropharyngeal cavities. Peak gape area coincides with peak subambient buccal pressure. Increased velocity of hyoid area expansion is primarily responsible for generating peak subambient pressure in the buccal and hyoid regions. Pharyngeal expansion appears to function as a sink to receive water influx from the mouth, much like that of compensatory suction in bidirectional aquatic feeders. Interestingly, C. plagiosum generates large suction pressures while paradoxically compressing the buccal cavity laterally, delaying the time to peak pressure. This represents a fundamental difference from the mechanism used to generate suction in teleost fishes. Interestingly, pressure in the three cavities peaks in the posterior to anterior direction. The complex shape changes that the buccal cavity undergoes indicate that, as in teleosts, unsteady flow predominates during suction feeding. Several kinematic variables function together, with great variation over long gape cycles to

  11. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.

    Science.gov (United States)

    Dave, Mital H; Frotzler, Angela; Madjdpour, Caveh; Koepfer, Nelly; Weiss, Markus

    2011-01-01

    Aspiration past the tracheal tube cuff has been recognized to be a risk factor for the development of ventilator-associated pneumonia (VAP). This study investigated the effect of closed tracheal suctioning on aspiration of fluid past the tracheal tube cuff in an in vitro benchtop model. High-volume low pressure tube cuffs of 7.5 mm internal diameter (ID) were placed in a 22 mm ID artificial trachea connected to a test lung. Positive pressure ventilation (PPV) with 15 cm H₂O peak inspiratory pressure and 5 cm H₂O positive end-expiratory pressure (PEEP) was used. A closed tracheal suction system (CTSS) catheter (size 14Fr) was attached to the tracheal tube and suction was performed for 5, 10, 15, or 20 seconds under 200 or 300 cm H₂O suction pressures. Amount of fluid (mL) aspirated along the tube cuff and the airway pressure changes were recorded for each suction procedure. Fluid aspiration during different suction conditions was compared using Kruskal-Wallis and Mann-Whitney test (Bonferroni correction [α = .01]). During 10, 15, and 20 seconds suction, airway pressure consistently dropped down to -8 to -13 cm H₂O (P aspiration was never observed under PPV + PEEP but occurred always during suctioning. Aspiration along the tube cuff was higher with -300 cm H₂O than with -200 cm H₂O suction pressure (P aspiration of fluid occurs along the tracheal tube cuff during suction with the closed tracheal suction system. © SAGE Publications 2011.

  12. Dynamic stiffness of horizontally vibrating suction caissons

    DEFF Research Database (Denmark)

    Latini, Chiara; Zania, Varvara; Cisternino, Michele

    2016-01-01

    The promising potential for offshore wind market is on developing wind farms in deeper waters with bigger turbines. In deeper waters the design foundation configuration may consist of jacket structures supported by floating piles or by suction caissons. Taking the soil-structure interaction effects...... into consideration requires the prior estimation of the dynamic impedances of the foundation. Even though numerous studies exist for piles, only limited number of publications can be found for suction caissons subjected to dynamic loads. Therefore, the purpose of this study is to examine the dynamic response...... of this type of foundation using the finite element method (FEM) to account for the interaction with the soil. 3D numerical models for both the soil and the suction caisson are formulated in a frequency domain. The response of the soil surrounding the foundation is considered linear viscoelastic...

  13. Cavitation simulation and NPSH prediction of a double suction centrifugal pump

    International Nuclear Information System (INIS)

    Li, P; Huang, Y F; Li, J

    2012-01-01

    This paper illustrates the flow field numerical analysis of the double-suction centrifugal pump. For the study of the cavitation flow inside the double-suction centrifugal pump, the professional pump/motor simulation software PumpLinx and its Full Cavitation Model has been employed. According to the PumpLinx calculation result and the Cavitation damage index, the cavitation position, level and the cavitation characteristics of the double-suction centrifugal pump has been predicted. For the further objective, the simulation of the flow field in the double-suction centrifugal pump under different inlet conditions has been carried out. By the result analysis, NPSHr has been predicted; the reliability of the results has been verified by comparing with the experimental data. At the same time, this practice can provide guidance for the optimal design of double-suction pump.

  14. Seepage Study for Suction Installation of Bucket Foundation in Different Soil Combinations

    DEFF Research Database (Denmark)

    Koteras, Aleksandra Katarzyna; Ibsen, Lars Bo; Clausen, Johan Christian

    2016-01-01

    Research has proven the bucket foundation to be a feasible and an attractive solution for offshore wind turbines. Its potential derives partly from the cost-effectiveness due to the suction-assisted installation. The suction applied under the bucket lid produces a downward driving force and addit......Research has proven the bucket foundation to be a feasible and an attractive solution for offshore wind turbines. Its potential derives partly from the cost-effectiveness due to the suction-assisted installation. The suction applied under the bucket lid produces a downward driving force...... around the bucket skirt. The exceedance of critical suction might lead to installation failure due to formation of piping channels, which break the hydraulic seal between the skirt and soil. The excess pore pressure arising due to applied suction changes the effective stress, hence the penetration...

  15. Feeding kinematics, suction, and hydraulic jetting performance of harbor seals (Phoca vitulina.

    Directory of Open Access Journals (Sweden)

    Christopher D Marshall

    Full Text Available The feeding kinematics, suction and hydraulic jetting capabilities of captive harbor seals (Phoca vitulina were characterized during controlled feeding trials. Feeding trials were conducted using a feeding apparatus that allowed a choice between biting and suction, but also presented food that could be ingested only by suction. Subambient pressure exerted during suction feeding behaviors was directly measured using pressure transducers. The mean feeding cycle duration for suction-feeding events was significantly shorter (0.15±0.09 s; P<0.01 than biting feeding events (0.18±0.08 s. Subjects feeding in-water used both a suction and a biting feeding mode. Suction was the favored feeding mode (84% of all feeding events compared to biting, but biting comprised 16% of feeding events. In addition, seals occasionally alternated suction with hydraulic jetting, or used hydraulic jetting independently, to remove fish from the apparatus. Suction and biting feeding modes were kinematically distinct regardless of feeding location (in-water vs. on-land. Suction was characterized by a significantly smaller gape (1.3±0.23 cm; P<0.001 and gape angle (12.9±2.02°, pursing of the rostral lips to form a circular aperture, and pursing of the lateral lips to occlude lateral gape. Biting was characterized by a large gape (3.63±0.21 cm and gape angle (28.8±1.80°; P<0.001 and lip curling to expose teeth. The maximum subambient pressure recorded was 48.8 kPa. In addition, harbor seals were able to jet water at food items using suprambient pressure, also known as hydraulic jetting. The maximum hydraulic jetting force recorded was 53.9 kPa. Suction and hydraulic jetting where employed 90.5% and 9.5%, respectively, during underwater feeding events. Harbor seals displayed a wide repertoire of behaviorally flexible feeding strategies to ingest fish from the feeding apparatus. Such flexibility of feeding strategies and biomechanics likely forms the basis of their

  16. Bio-inspired Miniature Suction Cups Actuated by Shape Memory Alloy

    Directory of Open Access Journals (Sweden)

    Hu Bing-shan

    2010-02-01

    Full Text Available Wall climbing robots using negative pressure suction always employ air pumps which have great noise and large volume. Two prototypes of bio-inspired miniature suction cup actuated by shape memory alloy (SMA are designed based on studying characteristics of biologic suction apparatuses, and the suction cups in this paper can be used as adhesion mechanisms for miniature wall climbing robots without air pumps. The first prototype with a two-way shape memory effect (TWSME extension TiNi spring imitates the piston structure of the stalked sucker; the second one actuated by a one way SMA actuator with a bias has a basic structure of stiff margin, guiding element, leader and elastic element. Analytical model of the second prototype is founded considering the constitutive model of the SMA actuator, the deflection of the thin elastic plate under compound load and the thermo-dynamic model of the sealed air cavity. Experiments are done to test their suction characteristics, and the analytical model of the second prototype is simulated on Matlab/simulink platform and validated by experiments.

  17. Bio-inspired Miniature Suction Cups Actuated by Shape Memory Alloy

    Directory of Open Access Journals (Sweden)

    Hu Bing-Shan

    2009-09-01

    Full Text Available Wall climbing robots using negative pressure suction always employ air pumps which have great noise and large volume. Two prototypes of bio-inspired miniature suction cup actuated by shape memory alloy (SMA are designed based on studying characteristics of biologic suction apparatuses, and the suction cups in this paper can be used as adhesion mechanisms for miniature wall climbing robots without air pumps. The first prototype with a two-way shape memory effect (TWSME extension TiNi spring imitates the piston structure of the stalked sucker; the second one actuated by a one way SMA actuator with a bias has a basic structure of stiff margin, guiding element, leader and elastic element. Analytical model of the second prototype is founded considering the constitutive model of the SMA actuator, the deflection of the thin elastic plate under compound load and the thermo-dynamic model of the sealed air cavity. Experiments are done to test their suction characteristics, and the analytical model of the second prototype is simulated on Matlab/simulink platform and validated by experiments.

  18. Installation process of suction anchors in Gulf of Guinea clay : Centrifuge modelling

    OpenAIRE

    THOREL, Luc; GARNIER, Jacques; RAULT, Gérard; DENDANI, Hédi; COLLIAT, JL

    2010-01-01

    The preparation process of a deepwater Gulf of Guinea clay for modelling of 24 m long suction anchors at a scale of 1/100 in the LCPC centrifuge, the clay characteristics and the installation phase (self-weight and suction) are presented. Two types of caissons have been tested in each tub : one with stiffeners and the other without stiffener. The embedment ratio is close to the suction caisson's slenderness of 3. An analysis of the forces of suction and soil friction shows, as expected, hi...

  19. Dynamic stiffness of suction caissons

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Liingaard, Morten; Andersen, Lars

    This report concerns the dynamic soil-structure interaction of steel suction caissons applied as foundations for offshore wind turbines. An emphasis is put on torsional vibrations and coupled sliding/rocking motion, and the influence of the foundation geometry and the properties of the surrounding...... soil is examined. The soil is simplified as a homogenous linear viscoelastic material and the dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequency-dependent coefficients corresponding to the different degrees of freedom. The dynamic stiffness coefficients...... for the skirted foundation are evaluated by means of a three-dimensional coupled boundary element/finite element model. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been...

  20. Effects of shallow and deep endotracheal tube suctioning on cardiovascular indices in patients in intensive care units.

    Science.gov (United States)

    Irajpour, Alireza; Abbasinia, Mohammad; Hoseini, Abbas; Kashefi, Parviz

    2014-07-01

    Clearing the endotracheal tube through suctioning should be done to promote oxygenation. Depth of suctioning is one of the variables in this regard. In shallow suctioning method, the catheter passes to the tip of the endotracheal tube, and in deep suctioning method, it passes beyond the tip into the trachea or brunches. This study aimed to evaluate the effect of shallow and deep suctioning methods on cardiovascular indices in patients hospitalized in the intensive care units (ICUs). In this clinical trial, 74 patients were selected among those who had undergone mechanical ventilation in the ICU of Al-Zahra Hospital, Isfahan, Iran using convenience sampling method. The subjects were randomly allocated to shallow and deep suctioning groups. Heart rate (HR) and blood pressure (BP) were measured immediately before and 1, 2, and 3 min after each suctioning. Number of times of suctioning was also noted in both the groups. Data were analyzed using repeated measures analysis of variance (ANOVA), Chi-square and independent t-tests. HR and BP were significantly increased after suctioning in both the groups (P 0.05). The suctioning count was significantly higher in the shallow suctioning group than in the deep suctioning group. Shallow and deep suctioning were similar in their effects on HR and BP, but shallow suctioning caused further manipulation of patient's trachea than deep suctioning method. Therefore, in order to prevent complications, nurses are recommended to perform the endotracheal tube suctioning by the deep method.

  1. Dynamic stiffness of suction caissons - vertical vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Ibsen, Lars Bo; Liingaard, M.; Andersen, Lars

    2006-12-15

    The dynamic response of offshore wind turbines are affected by the properties of the foundation and the subsoil. The purpose of this report is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigation is limited to a determination of the vertical dynamic stiffness of suction caissons. The soil surrounding the foundation is homogenous with linear viscoelastic properties. The dynamic stiffness of the suction caisson is expressed by dimensionless frequency-dependent dynamic stiffness coefficients corresponding to the vertical degree of freedom. The dynamic stiffness coefficients for the foundations are evaluated by means of a dynamic three-dimensional coupled Boundary Element/Finite Element model. Comparisons are made with known analytical and numerical solutions in order to evaluate the static and dynamic behaviour of the Boundary Element/Finite Element model. The vertical frequency dependent stiffness has been determined for different combinations of the skirt length, Poisson's ratio and the ratio between soil stiffness and skirt stiffness. Finally the dynamic behaviour at high frequencies is investigated. (au)

  2. Spinal cord electrophysiology II: extracellular suction electrode fabrication.

    Science.gov (United States)

    Garudadri, Suresh; Gallarda, Benjamin; Pfaff, Samuel; Alaynick, William

    2011-02-20

    Development of neural circuitries and locomotion can be studied using neonatal rodent spinal cord central pattern generator (CPG) behavior. We demonstrate a method to fabricate suction electrodes that are used to examine CPG activity, or fictive locomotion, in dissected rodent spinal cords. The rodent spinal cords are placed in artificial cerebrospinal fluid and the ventral roots are drawn into the suction electrode. The electrode is constructed by modifying a commercially available suction electrode. A heavier silver wire is used instead of the standard wire given by the commercially available electrode. The glass tip on the commercial electrode is replaced with a plastic tip for increased durability. We prepare hand drawn electrodes and electrodes made from specific sizes of tubing, allowing consistency and reproducibility. Data is collected using an amplifier and neurogram acquisition software. Recordings are performed on an air table within a Faraday cage to prevent mechanical and electrical interference, respectively.

  3. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  4. Effect of suction on the mechanical characteristics of uniformly compacted rammed earth

    Science.gov (United States)

    El Hajjar, A.; Chauhan, P.; Prime, N.; Plé, O.

    2018-04-01

    Rammed earth, in the current environmental situation, is an alternative construction technique which can help in reducing energy and raw material consumption owing to its “sustainable” characteristics. To fully understand its behavior and properties, recent scientific investigations consider it as a compacted unsaturated material with suction as its one of the main sources of strength. Eathern constructions face, over their lifetime, variations in the suction state which have a significant impact on their mechanical characteristics. In the present contribution, unconfined compression tests are performed, with and without unload-reload cycles, on homogeneously compacted samples subjected to various suction conditions. This study shows that both the unconfined compressive strength and Young modulus reduce with the reduction of suction states. Suction also seems to influence the amount of plastic strains and damage phenomenon. Indeed, the soils analyzed are slightly active and shows both plasticity behavior and damage phenomenon.

  5. Deep versus shallow suction of endotracheal tubes in ventilated neonates and young infants.

    Science.gov (United States)

    Gillies, Donna; Spence, Kaye

    2011-07-06

    Mechanical ventilation is commonly used in Neonatal Intensive Care Units to assist breathing in a variety of conditions. Mechanical ventilation is achieved through the placement of an endotracheal tube (ETT) which is left in-situ. The ETT is suctioned to prevent a build-up of secretions and blockage of the airway. Methods of suctioning the endotracheal tube vary according to institutional practice and the individual clinician performing the task. The depth of suctioning is one of these variables. The catheter may be passed to the tip of the ETT or beyond the tip into the trachea or bronchi to facilitate removal of secretions. However, trauma to the lower airways may result from the suction catheter being passed into the airway beyond the tip of the endotracheal tube. To compare the effectiveness and complications of deep (catheter passed beyond the tip of the ETT) versus shallow (catheter passed to length of ETT only) suctioning of the endotracheal tube in ventilated infants. In this first update the searches were expanded to the Cochrane Central Register of Controlled Trials (The Cochrane Library, March 30), MEDLINE (from January 1966 to May 30 2011), CINAHL (from 1982 to May 30 2011) and EMBASE (1980 to May 2011) using text words and subject headings relevant to endotracheal suctioning. There were no language restrictions. Controlled trials using random or quasi-random allocation of neonates receiving ventilatory support via an endotracheal tube to either deep or shallow endotracheal suctioning. The updated search resulted in 149 potentially relevant references. Two of the studies from this search were identified as potentially relevant. We included one of the potentially relevant studies and the other was excluded because it did not fit the inclusion criteria. One small crossover trial (n = 27) of shallow versus deep suctioning met the criteria for inclusion in this review. The reported outcomes were oxygen saturation and heart rate, during and after suctioning

  6. Numerical Buckling Analysis of Large Suction Caissons for Wind Turbines on Deep Water

    DEFF Research Database (Denmark)

    Madsen, Søren; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    2013-01-01

    Using large suction caissons for offshore wind turbines is an upcoming cost-effective technology also referred to as bucket foundations. During operation, the monopod bucket foundation is loaded by a large overturning moment from the wind turbine and the wave loads. However, during installation...... the suction caisson is loaded by external pressure (internal suction) due to evacuation of water inside the bucket and vertical forces due to gravity. The risk of structural buckling during installation of large-diameter suction caissons is addressed using numerical methods. Initial imperfect geometries...

  7. Vortex lift augmentation by suction on a 60 deg swept Gothic wing

    Science.gov (United States)

    Taylor, A. H.; Jackson, L. R.; Huffman, J. K.

    1982-01-01

    An experimental investigation was conducted in the Langley high-speed 7- by 10-foot wind tunnel to determine the aerodynamic performance of suction applied near the wing tips above the trailing edge of a 60 deg swept Gothic wing. Moveable suction inlets were symmetrically mounted in the proximity of the trailing edge, and the amount of suction was varied to maximize wing lift. Tests were conducted at Mach 0.15, 0.30, and 0.45, and the angle of attack was varied from -4 to 50 deg. The suction augmentation increases the lift coefficient over the entire range of angle of attack. The lift improvement exceeds the unaugmented wing lift by over 20%. Moreover, the augmented lift exceeds the lift predicted by vortex lattice theory to 30 deg angle of attack. Suction augmentation is postulated to strengthen the vortex system by increasing its velocity and making it more concentrated. This causes the vortex breakdown to be delayed to a higher angle of attack

  8. Evaluation of Karl Storz CMAC TipTM Device Versus Traditional Airway Suction in a Cadaver Model

    Directory of Open Access Journals (Sweden)

    Demis N. Lipe

    2014-07-01

    Full Text Available Introduction: We compared the efficacy of Karl Storz CMAC TipTM with inline suction to CMAC with traditional suction device in cadaveric models simulating difficult airways, using media mimicking pulmonary edema and vomit. Methods: This was a prospective, cohort study in which we invited emergency medicine faculty and residents to participate. Each participant intubated 2 cadavers (one with simulated pulmonary edema and one with simulated vomit, using CMAC with inline suction and CMAC with traditional suction. Thirty emergency medicine providers performed 4 total intubations each in a crossover trial comparing the CMAC with inline suction and CMAC with traditional suction. Two intubations were performed with simulated vomit and two with simulated pulmonary edema. The primary outcome was time to successful intubation; and the secondary outcome was proportion of successful intubation. Results: The median time to successful intubation using the CMAC with inline suction versus traditional suction in the pulmonary edema group was 29s and 30s respectively (p=0.54. In the vomit simulation, the median time to successful intubation was 40s using the CMAC with inline suction and 41s using the CMAC with traditional suction (p=0.70. There were no significant differences in time to successful intubation between the 2 devices. Similarly, the proportions of successful intubation were also not statistically significant between the 2 devices. The proportions of successful intubations using the inline suction were 96.7% and 73.3%, for the pulmonary edema and vomit groups, respectively. Additionally using the handheld suction device, the proportions for the pulmonary edema and vomit group were 100% and 66.7%, respectively. Conclusion: CMAC with inline suction was no different than CMAC with traditional suction and was associated with no statistically significant differences in median time to intubation or proportion of successful intubations. [West J Emerg Med

  9. Absence of suction feeding ichthyosaurs and its implications for triassic mesopelagic paleoecology.

    Science.gov (United States)

    Motani, Ryosuke; Ji, Cheng; Tomita, Taketeru; Kelley, Neil; Maxwell, Erin; Jiang, Da-yong; Sander, Paul Martin

    2013-01-01

    Mesozoic marine reptiles and modern marine mammals are often considered ecological analogs, but the extent of their similarity is largely unknown. Particularly important is the presence/absence of deep-diving suction feeders among Mesozoic marine reptiles because this would indicate the establishment of mesopelagic cephalopod and fish communities in the Mesozoic. A recent study suggested that diverse suction feeders, resembling the extant beaked whales, evolved among ichthyosaurs in the Triassic. However, this hypothesis has not been tested quantitatively. We examined four osteological features of jawed vertebrates that are closely linked to the mechanism of suction feeding, namely hyoid corpus ossification/calcification, hyobranchial apparatus robustness, mandibular bluntness, and mandibular pressure concentration index. Measurements were taken from 18 species of Triassic and Early Jurassic ichthyosaurs, including the presumed suction feeders. Statistical comparisons with extant sharks and marine mammals of known diets suggest that ichthyosaurian hyobranchial bones are significantly more slender than in suction-feeding sharks or cetaceans but similar to those of ram-feeding sharks. Most importantly, an ossified hyoid corpus to which hyoid retractor muscles attach is unknown in all but one ichthyosaur, whereas a strong integration of the ossified corpus and cornua of the hyobranchial apparatus has been identified in the literature as an important feature of suction feeders. Also, ichthyosaurian mandibles do not narrow rapidly to allow high suction pressure concentration within the oral cavity, unlike in beaked whales or sperm whales. In conclusion, it is most likely that Triassic and Early Jurassic ichthyosaurs were 'ram-feeders', without any beaked-whale-like suction feeder among them. When combined with the inferred inability for dim-light vision in relevant Triassic ichthyosaurs, the fossil record of ichthyosaurs does not suggest the establishment of modern

  10. Morphology, Kinematics, and Dynamics: The Mechanics of Suction Feeding in Fishes.

    Science.gov (United States)

    Day, Steven W; Higham, Timothy E; Holzman, Roi; Van Wassenbergh, Sam

    2015-07-01

    Suction feeding is pervasive among aquatic vertebrates, and our understanding of the functional morphology and biomechanics of suction feeding has recently been advanced by combining experimental and modeling approaches. Key advances include the visualization of the patterns of flow in front of the mouth of a feeding fish, the measurement of pressure inside their mouth cavity, and the employment of analytical and computational models. Here, we review the key components of the morphology and kinematics of the suction-feeding system of anatomically generalized, adult ray-finned fishes, followed by an overview of the hydrodynamics involved. In the suction-feeding apparatus, a strong mechanistic link among morphology, kinematics, and the capture of prey is manifested through the hydrodynamic interactions between the suction flows and solid surfaces (the mouth cavity and the prey). It is therefore a powerful experimental system in which the ecology and evolution of the capture of prey can be studied based on first principals. © The Author 2015. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  11. Impedance of flexible suction caissons

    DEFF Research Database (Denmark)

    Liingaard, Morten; Andersen, Lars; Ibsen, Lars Bo

    2007-01-01

    The dynamic response of offshore wind turbines is affected by the properties of the foundation and the subsoil. The aim of this paper is to evaluate the dynamic soil-structure interaction of suction caissons for offshore wind turbines. The investigations include evaluation of the vertical and cou...

  12. Turbulent flow with suction in smooth and rough pipes

    International Nuclear Information System (INIS)

    Verdier, Andre.

    1977-11-01

    It concerns an experimental study of turbulent flow inside a pipe with rough and porous wall and suction applied through it. The first part recall the basic knowledge concerning the turbulent flow with roughness. In second part statistical equations of fluid wall stress are written in the case of a permeable rough wall, in order to underline the respective role played by viscosity and pressure terms. In the third part the dynamic equilibrium of the flow is experimentally undertaken in the smooth and rough range with and without wall suction. Some empirical formulae are proposed for the mean velocity profiles in the inertial range and for friction velocity with suction. In the case of the sand roughness used, it does not seem that critical Reynolds number of transition from smooth to rough range is varied [fr

  13. A compliant underactuated hand with suction flow for underwater mobile manipulation

    KAUST Repository

    Stuart, Hannah S.

    2014-05-01

    © 2014 IEEE. Fingertip suction is investigated using a compliant, underactuated, tendon-driven hand designed for underwater mobile manipulation. Tendon routing and joint stiffnesses are designed to provide ease of closure while maintaining finger rigidity, allowing the hand to pinch small objects, as well as secure large objects, without diminishing strength. While the hand is designed to grasp a range of objects, the addition of light suction flow to the fingertips is especially effective for small, low-friction (slippery) objects. Numerical simulations confirm that changing suction parameters can increase the object acquisition region, providing guidelines for future versions of the hand.

  14. A compliant underactuated hand with suction flow for underwater mobile manipulation

    KAUST Repository

    Stuart, Hannah S.; Wang, Shiquan; Gardineer, Bayard; Christensen, David L.; Aukes, Daniel M.; Cutkosky, Mark

    2014-01-01

    © 2014 IEEE. Fingertip suction is investigated using a compliant, underactuated, tendon-driven hand designed for underwater mobile manipulation. Tendon routing and joint stiffnesses are designed to provide ease of closure while maintaining finger rigidity, allowing the hand to pinch small objects, as well as secure large objects, without diminishing strength. While the hand is designed to grasp a range of objects, the addition of light suction flow to the fingertips is especially effective for small, low-friction (slippery) objects. Numerical simulations confirm that changing suction parameters can increase the object acquisition region, providing guidelines for future versions of the hand.

  15. Absence of suction feeding ichthyosaurs and its implications for triassic mesopelagic paleoecology.

    Directory of Open Access Journals (Sweden)

    Ryosuke Motani

    Full Text Available Mesozoic marine reptiles and modern marine mammals are often considered ecological analogs, but the extent of their similarity is largely unknown. Particularly important is the presence/absence of deep-diving suction feeders among Mesozoic marine reptiles because this would indicate the establishment of mesopelagic cephalopod and fish communities in the Mesozoic. A recent study suggested that diverse suction feeders, resembling the extant beaked whales, evolved among ichthyosaurs in the Triassic. However, this hypothesis has not been tested quantitatively. We examined four osteological features of jawed vertebrates that are closely linked to the mechanism of suction feeding, namely hyoid corpus ossification/calcification, hyobranchial apparatus robustness, mandibular bluntness, and mandibular pressure concentration index. Measurements were taken from 18 species of Triassic and Early Jurassic ichthyosaurs, including the presumed suction feeders. Statistical comparisons with extant sharks and marine mammals of known diets suggest that ichthyosaurian hyobranchial bones are significantly more slender than in suction-feeding sharks or cetaceans but similar to those of ram-feeding sharks. Most importantly, an ossified hyoid corpus to which hyoid retractor muscles attach is unknown in all but one ichthyosaur, whereas a strong integration of the ossified corpus and cornua of the hyobranchial apparatus has been identified in the literature as an important feature of suction feeders. Also, ichthyosaurian mandibles do not narrow rapidly to allow high suction pressure concentration within the oral cavity, unlike in beaked whales or sperm whales. In conclusion, it is most likely that Triassic and Early Jurassic ichthyosaurs were 'ram-feeders', without any beaked-whale-like suction feeder among them. When combined with the inferred inability for dim-light vision in relevant Triassic ichthyosaurs, the fossil record of ichthyosaurs does not suggest the

  16. A Technique for Controlling Matric Suction on Filter Papers . GroWth ...

    African Journals Online (AJOL)

    'Abstract. Moist filter papers are widely usedfor seed gennination tests but their water confent and matric suction are not usually controlled. A technique for controlling filter paper matric suction is described and usedfor germination studies involving fresh and aged sorghum seed (Sorghummcolor (L) Moench). Filter papers ...

  17. Investigation on compression behaviour of highly compacted GMZ01 bentonite with suction and temperature control

    International Nuclear Information System (INIS)

    Ye, W.M.; Zhang, Y.W.; Chen, B.; Zheng, Z.J.; Chen, Y.G.; Cui, Y.J.

    2012-01-01

    Highlights: ► Heating induced volumetric change of GMZ01 bentonite depends on suction. ► Suction has significant influence on compressibility. ► Temperature has slight influence on compressibility. - Abstract: In this paper, an oedometer with suction and temperature control was developed. Mechanical compaction tests have been performed on the highly compacted GMZ01 bentonite, which has been recognized as potential buffer/backfill material for construction of Chinese high-level radioactive waste (HLW) geological repository, under conditions of suction ranging from 0 to 110 MPa, temperature from 20 to 80 °C and vertical pressure from 0.1 to 80 MPa. Based on the test results, suction and temperature effects on compressibility parameters are investigated. Results reveal that: (1) at high suctions, heating induced an expansion, while contraction is induced by heating at low suctions. The thermal expansion coefficient of GMZ01 bentonite measured is 1 × 10 −4 °C −1 ; (2) with increasing suction, the elastic compressibility κ and the plastic compressibility λ(s) of the highly compacted GMZ01 bentonite decrease, while the pre-consolidation pressure increases markedly; (3) with increasing temperature, the elastic compressibility of compacted GMZ01 bentonite changes insignificantly, while the plastic compressibility λ(s) slightly decreases and the yield surface tends to shrink.

  18. A Technique for Controlling Matric Suction on Filter Papers Used in ...

    African Journals Online (AJOL)

    Moist filter papers are widely usedfor seed gennination tests but their water confent and matric suction are not usually controlled. A technique for controlling filter paper matric suction is described and usedfor germination studies involving fresh and aged sorghum seed (Sorghummcolor (L) Moench). Filter papers wetted to ...

  19. 21 CFR 870.4270 - Cardiopulmonary bypass cardiotomy suction line blood filter.

    Science.gov (United States)

    2010-04-01

    ... blood filter. 870.4270 Section 870.4270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Devices § 870.4270 Cardiopulmonary bypass cardiotomy suction line blood filter. (a) Identification. A cardiopulmonary bypass cardiotomy suction line blood filter is a device used as part of a gas exchange (oxygenator...

  20. Reliability and criterion-related validity testing (construct) of the Endotracheal Suction Assessment Tool (ESAT©).

    Science.gov (United States)

    Davies, Kylie; Bulsara, Max K; Ramelet, Anne-Sylvie; Monterosso, Leanne

    2018-05-01

    To establish criterion-related construct validity and test-retest reliability for the Endotracheal Suction Assessment Tool© (ESAT©). Endotracheal tube suction performed in children can significantly affect clinical stability. Previously identified clinical indicators for endotracheal tube suction were used as criteria when designing the ESAT©. Content validity was reported previously. The final stages of psychometric testing are presented. Observational testing was used to measure construct validity and determine whether the ESAT© could guide "inexperienced" paediatric intensive care nurses' decision-making regarding endotracheal tube suction. Test-retest reliability of the ESAT© was performed at two time points. The researchers and paediatric intensive care nurse "experts" developed 10 hypothetical clinical scenarios with predetermined endotracheal tube suction outcomes. "Experienced" (n = 12) and "inexperienced" (n = 14) paediatric intensive care nurses were presented with the scenarios and the ESAT© guiding decision-making about whether to perform endotracheal tube suction for each scenario. Outcomes were compared with those predetermined by the "experts" (n = 9). Test-retest reliability of the ESAT© was measured at two consecutive time points (4 weeks apart) with "experienced" and "inexperienced" paediatric intensive care nurses using the same scenarios and tool to guide decision-making. No differences were observed between endotracheal tube suction decisions made by "experts" (n = 9), "inexperienced" (n = 14) and "experienced" (n = 12) nurses confirming the tool's construct validity. No differences were observed between groups for endotracheal tube suction decisions at T1 and T2. Criterion-related construct validity and test-retest reliability of the ESAT© were demonstrated. Further testing is recommended to confirm reliability in the clinical setting with the "inexperienced" nurse to guide decision-making related to endotracheal tube

  1. Analisis Perubahan Nilai Suction Akibat Hujan Terhadap Kestabilan Lereng

    OpenAIRE

    Martini, Martini

    2009-01-01

    Infiltration of rainfall into slope will have an effect on to condition of slope hydrology and more specifically to characteristic of slope soils, for example pore water pressure value, level of saturation, weight contents of soil, shear strength of soil. Pore water pressure value at dry soil condition or wet condition called as with pore water pressure value negatife or value suction. This suction value will tend to declines and in the end becomes equal to zero or bigger than 0 ( positive po...

  2. Comparative study of the characteristics of some suction devices for gas sampling applications

    International Nuclear Information System (INIS)

    Donguy, R.; Drouet, J.

    1959-06-01

    Gas sampling (used to determine the characteristics of dusts or aerosols contained in a gas) needs a suction device. In order to select the right device and the right conditions of use, the characteristics and performances of various suction devices (helicoidal and centrifugal aspirators, air pumps, volumetric pumps) have been experimentally measured: flow rate, head loss, sampling volume and duration, aerosol and dust concentration, gas density, nature of the gas, suction circuit configuration, etc

  3. Investigation on compression behaviour of highly compacted GMZ01 bentonite with suction and temperature control

    Energy Technology Data Exchange (ETDEWEB)

    Ye, W.M., E-mail: ye_tju@tongji.edu.cn [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); United Research Center for Urban Environment and Sustainable Development, The Ministry of Education, Shanghai 200092 (China); Zhang, Y.W.; Chen, B.; Zheng, Z.J.; Chen, Y.G. [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); Cui, Y.J. [Key Laboratory of Geotechnical and Underground Engineering of Ministry of Education, Tongji University, Shanghai 200092 (China); Ecole des Ponts ParisTech, UR Navier/CERMES 77455 (France)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer Heating induced volumetric change of GMZ01 bentonite depends on suction. Black-Right-Pointing-Pointer Suction has significant influence on compressibility. Black-Right-Pointing-Pointer Temperature has slight influence on compressibility. - Abstract: In this paper, an oedometer with suction and temperature control was developed. Mechanical compaction tests have been performed on the highly compacted GMZ01 bentonite, which has been recognized as potential buffer/backfill material for construction of Chinese high-level radioactive waste (HLW) geological repository, under conditions of suction ranging from 0 to 110 MPa, temperature from 20 to 80 Degree-Sign C and vertical pressure from 0.1 to 80 MPa. Based on the test results, suction and temperature effects on compressibility parameters are investigated. Results reveal that: (1) at high suctions, heating induced an expansion, while contraction is induced by heating at low suctions. The thermal expansion coefficient of GMZ01 bentonite measured is 1 Multiplication-Sign 10{sup -4} Degree-Sign C{sup -1}; (2) with increasing suction, the elastic compressibility {kappa} and the plastic compressibility {lambda}(s) of the highly compacted GMZ01 bentonite decrease, while the pre-consolidation pressure increases markedly; (3) with increasing temperature, the elastic compressibility of compacted GMZ01 bentonite changes insignificantly, while the plastic compressibility {lambda}(s) slightly decreases and the yield surface tends to shrink.

  4. Suction of MHD boundary layer flows

    International Nuclear Information System (INIS)

    Rao, B.N.

    1985-01-01

    The boundary layer growth with tensor electrical conductivity and the transpiration number has been examined using local nonsimilarity solutions method. It is found that suction will cause the increase in wall shearing stress and decrease in thicknesses of the boundary layer. (Auth.)

  5. Volume of blood suctioned during vacuum-assisted breast biopsy predicts later hematoma formation

    Directory of Open Access Journals (Sweden)

    Panopoulou Effrosyni

    2010-03-01

    Full Text Available Abstract Background To evaluate whether the volume of blood suctioned during vacuum-assisted breast biopsy (VABB is associated with hematoma formation and progression, patient's age and histology of the lesion. Findings 177 women underwent VABB according to standardized protocol. The volume of blood suctioned and hematoma formation were noted at the end of the procedure, as did the subsequent development and progression of hematoma. First- and second-order logistic regression was performed, where appropriate. Cases with hematoma presented with greater volume of blood suctioned (63.8 ± 44.7 cc vs. 17.2 ± 32.9 cc; p Conclusion The likelihood of hematoma is increasing along with increasing amount of blood suctioned, reaching a plateau approximately at 80 cc of blood lost.

  6. Pilot Study Comparing Closed Versus Open Tracheal Suctioning in Postoperative Neonates and Infants With Complex Congenital Heart Disease.

    Science.gov (United States)

    Tume, Lyvonne N; Baines, Paul B; Guerrero, Rafael; Hurley, Margaret A; Johnson, Robert; Kalantre, Atul; Ramaraj, Ram; Ritson, Paul C; Walsh, Laura; Arnold, Philip D

    2017-07-01

    To determine the hemodynamic effect of tracheal suction method in the first 36 hours after high-risk infant heart surgery on the PICU and to compare open and closed suctioning techniques. Pilot randomized crossover study. Single PICU in United Kingdom. Infants undergoing surgical palliation with Norwood Sano, modified Blalock-Taussig shunt, or pulmonary artery banding in the first 36 hours postoperatively. Infants were randomized to receive open or closed (in-line) tracheal suctioning either for their first or second study tracheal suction in the first 36 hours postoperatively. Twenty-four infants were enrolled over 18 months, 11 after modified Blalock-Taussig shunt, seven after Norwood Sano, and six after pulmonary artery banding. Thirteen patients received the open suction method first followed by the closed suction method second, and 11 patients received the closed suction method first followed by the open suction method second in the first 36 hours after their surgery. There were statistically significant larger changes in heart rate (p = 0.002), systolic blood pressure (p = 0.022), diastolic blood pressure (p = 0.009), mean blood pressure (p = 0.007), and arterial saturation (p = 0.040) using the open suction method, compared with closed suctioning, although none were clinically significant (defined as requiring any intervention). There were no clinically significant differences between closed and open tracheal suction methods; however, there were statistically significant greater changes in some hemodynamic variables with open tracheal suctioning, suggesting that closed technique may be safer in children with more precarious physiology.

  7. Rekonstruksi pada Perforasi Palatum Akibat Pneggunaan Gigi Tiruan Lengkap Rahang Atas dengan Suction Cup

    Directory of Open Access Journals (Sweden)

    Cristiani Nadya Pramasari

    2012-12-01

    Full Text Available Latar belakang. Pemasangan suction cup pada gigi tiruan lengkap rahang atas merupakan salah satu cara untuk meningkatkan referensi. Kondisi vakum oleh karena suction cup ini dalam waktu jangka panjang dan tidak terkontrol mengakibatkan nekrosis jaringan yaitu adanya perforasi palatum. Tujuan. Melaporkan rekonstruksi penutupan perforasi palatum sebagai komplikasi penggunaan gigi tiruan lengkap rahang atas dengan suction cup. Laporan Kasus. Pada tanggal 11 September 2012 seorang pria berusia 64 tahun datang ke Poliklinik Bedah Mulut RSUP dr. Sardjito Yogyakarta dengan keluhan terdapat lubang pada langit-langit. Pasien menggunakan gigi palsu buatan tukang gigi dengan perekat berbahan karet pada langit-langit selama 5 tahun. Selama penggunaan gigi palsu pasien sering mengalami sakit dan pembengkakan di langit-langit sampai keluar nanah dan akhirnya terbentuk lubang sehingga jika minum air keluar dari hidung. Pemeriksaan rontgen oklusal rahang atas tampak adanya resorbsi regio palatum durum. Rekonstruksi menggunakan teknik push back modifikasi dilakukan untuk penutupan perforasi palatum di bawah anestesi umum. Kesimpulan. Suction cup pada gigi tiruan lengkap rahang atas mengakibatkan kerusakan jaringan lunak dan jaringan keras rongga mulut. Perforasi palatum yang diakibatkan oleh suction cup ini dapat dilakukan rekonstruksi dengan teknik push back dengan hasil yang cukup optimal.   Background. Suction cups are used to get retention of the complete dentures. The uncontrolled constant vacuum created by the suction cup induces necrosis of tissues and perforation ofpalate. Objective. To report reconstruction for palatal perforation closure as a complication due to prolonged use of maxillary denture with suction cup. Case Report. A 64 years old male patient came to the Department of Oral Surgery, Sardjito General Hospital Yogyakarta on September 11, 2012 with the complaint of hole in his palate. He was wearing dentures for the past 5 years. He also

  8. MAXIMUM AIR SUCTION INTO HORIZONTAL OPEN ENDED CYLINDRICAL LOUVERED PIPE

    Directory of Open Access Journals (Sweden)

    SAMEER RANJAN SAHU

    2017-02-01

    Full Text Available The main approach behind the present numerical investigation is to estimate the mass flow rate of air sucked into a horizontal open-ended louvered pipe from the surrounding atmosphere. The present numerical investigation has been performed by solving the conservation equations for mass, momentum and energy along with two equation based k-ɛ model for a louvered horizontal cylindrical pipe by finite volume method. It has been found from the numerical investigation that mass suction rate of air into the pipe increases with increase in louvered opening area and the number of nozzles used. Keeping other parameters fixed, for a given mass flow rate there exists an optimum protrusion of nozzle for highest mass suction into the pipe. It was also found from the numerical investigation that increasing the pipe diameter the suction mass flow rate of air was increased.

  9. Bernoulli Suction Effect on Soap Bubble Blowing?

    Science.gov (United States)

    Davidson, John; Ryu, Sangjin

    2015-11-01

    As a model system for thin-film bubble with two gas-liquid interfaces, we experimentally investigated the pinch-off of soap bubble blowing. Using the lab-built bubble blower and high-speed videography, we have found that the scaling law exponent of soap bubble pinch-off is 2/3, which is similar to that of soap film bridge. Because air flowed through the decreasing neck of soap film tube, we studied possible Bernoulli suction effect on soap bubble pinch-off by evaluating the Reynolds number of airflow. Image processing was utilized to calculate approximate volume of growing soap film tube and the volume flow rate of the airflow, and the Reynolds number was estimated to be 800-3200. This result suggests that soap bubbling may involve the Bernoulli suction effect.

  10. Hydrodynamics of suction feeding in fish

    NARCIS (Netherlands)

    Muller, M.

    1983-01-01

    1. Suction feeding is the dominant way to obtain food in teleosts. Its high demands on structures due to the required velocities and forces leads to the expectation that a biophysical analysis will aid to reveal the adaptive significance of head and body structures related to this

  11. Suction forces generated by passive bile bag drainage on a model of post-subdural hematoma evacuation.

    Science.gov (United States)

    Tenny, Steven O; Thorell, William E

    2018-05-05

    Passive drainage systems are commonly used after subdural hematoma evacuation but there is a dearth of published data regarding the suction forces created. We set out to quantify the suction forces generated by a passive drainage system. We created a model of passive drainage after subdural hematoma evacuation. We measured the maximum suction force generated with a bile bag drain for both empty drain tubing and fluid-filled drain tube causing a siphoning effect. We took measurements at varying heights of the bile bag to analyze if bile bag height changed suction forces generated. An empty bile bag with no fluid in the drainage tube connected to a rigid, fluid-filled model creates minimal suction force of 0.9 mmHg (95% CI 0.64-1.16 mmHg). When fluid fills the drain tubing, a siphoning effect is created and can generate suction forces ranging from 18.7 to 30.6 mmHg depending on the relative position of the bile bag and filled amount of the bile bag. The suction forces generated are statistically different if the bile bag is 50 cm below, level with or 50 cm above the experimental model. Passive bile bag drainage does not generate significant suction on a fluid-filled rigid model if the drain tubing is empty. If fluid fills the drain tubing then siphoning occurs and can increase the suction force of a passive bile bag drainage system to levels comparable to partially filled Jackson-Pratt bulb drainage.

  12. Study on the performance improvement of multiblade fans. Effects of suction cones; Tayoku fan no seino kaizen ni kansuru kenkyu. Suction cone no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Kuratani, F.; Ogawa, T. [Hyogo University of Teacher Education, Hyogo (Japan); Yamamoto, S.

    1999-07-25

    In order to improve the performance of a multiblade fan, the effects of three types of suction cones of the fan casing on the fan efficiency and noise are investigated experimentally. The first type of the suction cone is the insertion type, which is inserted into the inside of the fan impeller. The second type is the extrusion type, which extrudes outside from the casing surface. The third type is the combination type of two types. The results of those three types are compared with those of the commonly used suction cone. The followings are made clear: (1) The insertion type and the extrusion type are effective in improving the efficiency and reducing noise. (2) The optimal lengths of the insertion and the extrusion exist. (3) The combination type is more effective in improving the efficiency. (4) The combination type with the skewed cutoff of the fan casing shows the best effect. (author)

  13. Characterization of zebrafish larvae suction feeding flow using μPIV and optical coherence tomography

    OpenAIRE

    Pekkan, Kerem; Uslu, Fazıl E.; Chang, Brain; Mani, Karthick; Chen, Chia-Yuan; Holzman, Roi

    2016-01-01

    The hydrodynamics of suction feeding is critical for the survival of fish larvae; failure to capture food during the onset of autonomous feeding can rapidly lead to starvation and mortality. Fluid mechanics experiments that investigate the suction feeding of suspended particles are limited to adult fishes, which operate at large Reynolds numbers. This manuscript presents the first literature results in which the external velocity fields generated during suction feeding of early zebrafish larv...

  14. Effects of Lavender Inhalant on the Pain during Endotracheal Suctioning in Intensive Care Unit Patients

    Directory of Open Access Journals (Sweden)

    M. Taheri Rezgh Abadi

    2017-09-01

    Full Text Available Aims: Patients undergoing artificial ventilation require tracheal tube suction because of inability to clear their effective airways, which is usually a painful process for the patients. The aim of this study was to investigate the effect of spike lavender’s inhalant on pain during tracheal tube suctioning in ICU intubated patients. Materials & Methods: In this double-blinded randomized clinical trial, 60 intubated patients hospitalized in ICU of Shahid Modarres Hospital of Kashmar City, Iran, in 2017 were selected by available and simple sampling method, and were randomly divided into 2 control and case groups (each 30 individuals. Before the standard suctioning process, the test group patients received inhalant of 2% spike lavender for 5 minutes and the control group received inhalant of distilled water. The level of pain was recorded before and during tracheal tube suctioning. Data were analyzed by SPSS 16 software using independent T, paired T, Fisher and Mann-Whitney U tests. Findings: There was no significant difference in pain score before tracheal tube suction between 2 groups (p>0.05. However, there were significant differences between the level of pain during tracheal tube suctioning and the pain was increased in both groups, but this increase was significantly higher in the control group (p<0.001. Conclusion: Spike lavender’s inhalant is effective on pain reduction during suctioning process of ICU intubated patients.

  15. Device for the prehension by means of suction cups

    International Nuclear Information System (INIS)

    Gabillet, Maurice

    1980-01-01

    The difficulties encountered while utilising suction-cups, are mainly caused by the skirts. The skirts are more or less adaptable to the surface of the objects to be handled. The skirt of the device presented, is made out of a round supple elastic bag containing solid particles. By creating a vacuum in the bag, the particles become a solid entity. The bag filled with the particles becomes rigid and can take exactly the shape of the object to be lifted. By creating a second vacuum in the axis of the bag, the object can be lifted. Several suction-cups can be used simultaneously

  16. Corner Separation Control by Boundary Layer Suction Applied to a Highly Loaded Axial Compressor Cascade

    Directory of Open Access Journals (Sweden)

    Yangwei Liu

    2014-11-01

    Full Text Available Control of corner separation has attracted much interest due to its improvement of performance and energy utilization in turbomachinery. Numerical studies have been performed under both design and off-design flow conditions to investigate the effects of boundary layer suction (BLS on corner separation in a highly loaded compressor cascade. Two new BLS slot configurations are proposed and a total of five suction slot configurations were studied and compared. Averaged static pressure rise, exit loss coefficient, passage blockage and flow turning angle have been given and compared systematically over a range of operation incidence angles. Distributions of significant loss removal, blade loading, exit deviation and total pressure loss at 3 degree and 7 degree incidence have also been studied. Under the same suction mass flows of 0.7% of the inlet mass flows, the pitchwise suction slot on the endwall shows a better optimal performance over the whole operation incidence among single suction slots. By using of the new proposed compound slot configuration with one spanwise slot on the blade suction side and one pitchwise slot on the endwall, the maximum reduction of total pressure loss at 7 degree incidence can be 39.4%.

  17. Functional morphology of the feeding apparatus, feeding constraints, and suction performance in the nurse shark Ginglymostoma cirratum.

    Science.gov (United States)

    Motta, Philip J; Hueter, Robert E; Tricas, Timothy C; Summers, Adam P; Huber, Daniel R; Lowry, Dayv; Mara, Kyle R; Matott, Michael P; Whitenack, Lisa B; Wintzer, Alpa P

    2008-09-01

    The nurse shark, Ginglymostoma cirratum, is an obligate suction feeder that preys on benthic invertebrates and fish. Its cranial morphology exhibits a suite of structural and functional modifications that facilitate this mode of prey capture. During suction-feeding, subambient pressure is generated by the ventral expansion of the hyoid apparatus and the floor of its buccopharyngeal cavity. As in suction-feeding bony fishes, the nurse shark exhibits expansive, compressive, and recovery kinematic phases that produce posterior-directed water flow through the buccopharyngeal cavity. However, there is generally neither a preparatory phase nor cranial elevation. Suction is generated by the rapid depression of the buccopharyngeal floor by the coracoarcualis, coracohyoideus, and coracobranchiales muscles. Because the hyoid arch of G. cirratum is loosely connected to the mandible, contraction of the rectus cervicis muscle group can greatly depress the floor of the buccopharyngeal cavity below the depressed mandible, resulting in large volumetric expansion. Suction pressures in the nurse shark vary greatly, but include the greatest subambient pressures reported for an aquatic-feeding vertebrate. Maximum suction pressure does not appear to be related to shark size, but is correlated with the rate of buccopharyngeal expansion. As in suction-feeding bony fishes, suction in the nurse shark is only effective within approximately 3 cm in front of the mouth. The foraging behavior of this shark is most likely constrained to ambushing or stalking due to the exponential decay of effective suction in front of the mouth. Prey capture may be facilitated by foraging within reef confines and close to the substrate, which can enhance the effective suction distance, or by foraging at night when it can more closely approach prey.

  18. Performance of high-area-ratio annular dump diffuser using suction-stabilized-vortex flow control

    Science.gov (United States)

    Juhasz, A. J.; Smith, J. M.

    1977-01-01

    A short annular dump diffuser having a geometry conductive to formation of suction stabilized toroidal vortices in the region of abrupt area change was tested. The overall diffuser area ratio was 4.0 and the length to inlet height ratio was 2.0. Performance data were obtained at near ambient temperature and pressure for inlet Mach numbers of 0.18 and 0.30 with suction rates ranging from 0 to 18 percent of total inlet mass flowrate. Results show that the exit velocity profile could be readily biased toward either wall by adjustment of inner and outer wall suction rates. Symmetric exit velocity profiles were inherently unstable with a tendency to revert to a hub or tip bias. Diffuser effectiveness was increased from about 38 percent without suction to over 85 percent at a total suction rate of 10 to 12 percent. At the same time diffuser total pressure loss was reduced from 3.1 percent to 1.1 percent at an inlet Mach number of 0.3.

  19. Modulation method of scroll compressor based on suction gas bypass

    International Nuclear Information System (INIS)

    Wang Baolong; Han Linjun; Shi Wenxing; Li Xianting

    2012-01-01

    The air conditioners and heat pumps tend to work in much mild environments and part load situations rather than provide the rated full capacity under severe rated testing conditions. Both the capacity and inner compression ratio of the compressor should be regulated according to the working condition for higher energy efficiency and occupants’ comfort. A potential modulating technology of the scroll compressor, suction gas bypass, is investigated in this paper. The principle and operation method are illuminated and the adaptability is validated by experiments and simulations. As a conclusion, an appropriate suction gas bypass can reduce the inner compression loss of the scroll compressor under over compression conditions, enhance the system COP and also largely decrease the heating/cooling capacity of the refrigeration/heat pump system. - Highlights: ► Suction gas bypass (SGB) is an effective regulating method of scroll compressor. ► SGB reduces the inner compression loss under over compression conditions. ► SGB largely decreases the heating/cooling capacity of the refrigeration system.

  20. Characterization of zebrafish larvae suction feeding flow using μPIV and optical coherence tomography

    Science.gov (United States)

    Pekkan, Kerem; Chang, Brian; Uslu, Fazil; Mani, Karthick; Chen, Chia-Yuan; Holzman, Roi

    2016-07-01

    The hydrodynamics of suction feeding is critical for the survival of fish larvae; failure to capture food during the onset of autonomous feeding can rapidly lead to starvation and mortality. Fluid mechanics experiments that investigate the suction feeding of suspended particles are limited to adult fishes, which operate at large Reynolds numbers. This manuscript presents the first literature results in which the external velocity fields generated during suction feeding of early zebrafish larvae (2500-20,000 μm total length) are reported using time-resolved microscopic particle image velocimetry. For the larval stages studied, the maximum peak suction velocity of the inflow bolus is measured at a finite distance from the mouth tip and ranges from 1 to 8 mm/s. The average pressure gradient and the velocity profile proximal to the buccal (mouth) cavity are calculated, and two distinct trends are identified. External recirculation regions and reverse flow feeding cycles are also observed and quantified. One of the unresolved questions in fish suction feeding is the shape and dynamics of the buccal cavity during suction feeding; optical coherence tomography imaging is found to be useful for reconstructing the mouth kinematics. The projected area of the mouth cavity during the feeding cycle varies up to 160 and 22 % for the transverse and mid-sagittal planes, respectively. These findings can inspire novel hydrodynamically efficient biomedical and microfluidic devices.

  1. New approach to the suction force at the leading edge of a profile with zero thickness

    NARCIS (Netherlands)

    Sparenberg, JA; de Jager, EM

    2004-01-01

    This paper considers the suction force at the leading edge of a profile with zero thickness in an incompressible and inviscid fluid flow. The theory is linear, and the approach to the suction force is from the innerside of the profile. It is shown that the suction force can be considered as an

  2. Pad for holding a load against a surface by suction

    International Nuclear Information System (INIS)

    Farmer, R.C.; Goldsmith, H.A.; Proudlove, M.J.

    1981-01-01

    This invention concerns suction pads for supporting loads. Specifically, the suction pad is part of a pair of pads located at the ends of a bridge forming a vehicle for transporting instruments for the non-destructive testing of a large vessel intended to contain a fuel assembly for a nuclear reactor immersed in a liquid metal coolant. For example, the vehicle is of the type described in the French patent application filed this day under the heading 'Vehicle for transporting instruments for testing against a wall' [fr

  3. INCOMPRESSIBLE LAMINAR BOUNDARY LAYER CONTROL BY BLOWING AND SUCTION

    Directory of Open Access Journals (Sweden)

    AZZEDINE NAHOUI

    2013-12-01

    Full Text Available A two-dimensional incompressible laminar boundary layer and its control using blowing and suction over a flat plate and around the NACA 0012 and 661012 profiles, is studied numerically. The study is based on the Prandtl boundary layer model using the finite differences method and the Crank-Nicolson scheme. The velocity distribution, the boundary layer thickness and the friction coefficient, are determined and presented with and without control. The application of the control technique, has demonstrated its positive effect on the transition point and the friction coefficient. Both control procedures are compared for different lengths, speeds and angles of blowing and suction.

  4. Reliable site for suction blister induction and harvesting

    Directory of Open Access Journals (Sweden)

    Laxmisha Chandrashekar

    2005-01-01

    Full Text Available Background: Suction blister grafting is a useful modality of treatment of patients with resistant and stable vitiligo. However, there have been no detailed studies to find out the best donor site for blister formation. Methods: The study was conducted between the period of October 2004 and February 2005 in the dermatology department at a tertiary care center. Nine patients with vitiligo (focal vitiligo, 3; mucosal vitiligo, 2; acrofacial vitiligo, 2; vitiligo vulgaris, 1; and segmental vitiligo, 1 were selected for blister harvesting and grafting. The blisters were raised using the method described by Gupta et al. Results: Suction blisters were attempted to be raised at 52 sites, but only 38 blisters could be raised, 24 complete and 14 incomplete. Blisters were raised in all the three cases on the flexor aspect of the arm (100%, 15 of 17 cases (88.2% on the flexor aspect of the forearm, 4 of 5 cases (80% on the abdomen, 11 of 16 cases (68.7% on the anterolateral thigh, and less frequently over leg or foot. Complete blisters were formed in 13/15 cases (86.6% on the flexor aspect of the forearm, 6/11 cases (54.5% on the anterolateral thigh, and in all cases over leg. Conclusion: The flexor aspect of the forearm is a good site for suction blister harvesting.

  5. Suppression of the secondary flow in a suction channel of a large centrifugal pump

    International Nuclear Information System (INIS)

    Torii, D; Nagahara, T; Okihara, T

    2013-01-01

    The suction channel configuration of a large centrifugal pump with a 90-degree bend was studied in detail to suppress the secondary flow at the impeller inlet for improving suction performance. Design of experiments (DOE) and computational fluid dynamics (CFD) were used to evaluate the sensitivity of several primary design parameters of the suction channel. A DOE is a powerful tool to clarify the sensitivity of objective functions to design parameters with a minimum of trials. An L9 orthogonal array was adopted in this study and nine suction channels were designed, through which the flow was predicted by steady state calculation. The results indicate that a smaller bend radius with a longer straight nozzle, distributed between the bend and the impeller, suppresses the secondary flow at the impeller inlet. An optimum ratio of the cross sectional areas at the bend inlet and outlet was also confirmed in relationship to the contraction rate of the downstream straight nozzle. These findings were obtained by CFD and verified by experiments. The results will aid the design of large centrifugal pumps with better suction performance and higher reliability

  6. Prospective randomized trial compares suction versus water seal for air leaks.

    Science.gov (United States)

    Cerfolio, R J; Bass, C; Katholi, C R

    2001-05-01

    Surgeons treat air leaks differently. Our goal was to evaluate whether it is better to place chest tubes on suction or water seal for stopping air leaks after pulmonary surgery. A second goal was to evaluate a new classification system for air leaks that we developed. Patients were prospectively randomized before surgery to receive suction or water seal to their chest tubes on postoperative day (POD) #2. Air leaks were described and quantified daily by a classification system and a leak meter. The air-leak meter scored leaks from 1 (least) to 7 (greatest). The group randomized to water seal stayed on water seal unless a pneumothorax developed. On POD #2, 33 of 140 patients had an air leak. Eighteen patients had been preoperatively randomized to water seal and 15 to suction. Air leaks resolved in 12 (67%) of the water seal patients by the morning of POD #3. All 6 patients whose air leak did not stop had a leak that was 4/7 or greater (p leak meter. Of the 15 patients randomized to suction, only 1 patient's air leak (7%) resolved by the morning of POD #3. The randomization aspect of the trial was ended and statistical analysis showed water seal was superior (p = 0.001). The remaining 14 patients were then placed to water seal and by the morning of POD #4, 13 patients' leaks had stopped. Of the 32 total patients placed to seal, 7 (22%) developed a pneumothorax and 6 of these 7 patients had leaks that were 4/7 or greater (p = 0.001). Placing chest tubes on water seal seems superior to wall suction for stopping air leaks after pulmonary resection. However, water seal does not stop expiratory leaks that are 4/7 or greater. Pneumothorax may occur when chest tubes are placed on seal with leaks this large.

  7. Necessity of suction drains in gynecomastia surgery.

    Science.gov (United States)

    Keskin, Mustafa; Sutcu, Mustafa; Cigsar, Bulent; Karacaoglan, Naci

    2014-05-01

    The aim of gynecomastia surgery is to restore a normal chest contour with minimal signs of breast surgery. The authors examine the rate of complications in gynecomastia surgery when no closed-suction drains are placed. One hundred thirty-eight consecutive male patients who underwent gynecomastia surgery without drains were retrospectively analyzed to determine whether the absence of drains adversely affected patient outcomes. Patients were managed by ultrasonic-assisted liposuction both with and without the pull-through technique. The mean age of the patients was 29 years, and the mean volume of breast tissue aspirated was 350 mL per beast. Pull-through was needed in 23 cases. There was only 1 postoperative hematoma. These results are comparable with previously published data for gynecomastia surgery in which drains were placed, suggesting that the absence of drains does not adversely affect postoperative recovery. Routine closed-suction drainage after gynecomastia surgery is unnecessary, and it may be appropriate to omit drains after gynecomastia surgery.

  8. CFD Analysis of a Centrifugal Fan for Performance Enhancement using Converging Boundary Layer Suction Slots

    OpenAIRE

    K. Vasudeva Karanth; N. Yagnesh Sharma

    2009-01-01

    Generally flow behavior in centrifugal fan is observed to be in a state of instability with flow separation zones on suction surface as well as near the front shroud. Overall performance of the diffusion process in a centrifugal fan could be enhanced by judiciously introducing the boundary layer suction slots. With easy accessibility of CFD as an analytical tool, an extensive numerical whole field analysis of the effect of boundary layer suction slots in discrete regions ...

  9. Modelling suction instabilities in soils at varying degrees of saturation

    Directory of Open Access Journals (Sweden)

    Buscarnera Giuseppe

    2016-01-01

    Full Text Available Wetting paths imparted by the natural environment and/or human activities affect the state of soils in the near-surface, promoting transitions across different regimes of saturation. This paper discusses a set of techniques aimed at quantifying the role of hydrologic processes on the hydro-mechanical stability of soil specimens subjected to saturation events. Emphasis is given to the mechanical conditions leading to coupled flow/deformation instabilities. For this purpose, energy balance arguments for three-phase systems are used to derive second-order work expressions applicable to various regimes of saturation. Controllability analyses are then performed to relate such work input with constitutive singularities that reflect the loss of strength under coupled and/or uncoupled hydro-mechanical forcing. A suction-dependent plastic model is finally used to track the evolution of stability conditions in samples subjected to wetting, thus quantifying the growth of the potential for coupled failure modes upon increasing degree of saturation. These findings are eventually linked with the properties of the field equations that govern pore pressure transients, thus disclosing a conceptual link between the onset of coupled hydro-mechanical failures and the evolution of suction with time. Such results point out that mathematical instabilities caused by a non-linear suction dependent behaviour play an important role in the advanced constitutive and/or numerical tools that are commonly used for the analysis of geomechanical problems in the unsaturated zone, and further stress that the relation between suction transients and soil deformations is a key factor for the interpretation of runaway failures caused by intense saturation events.

  10. 21 CFR 878.5040 - Suction lipoplasty system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suction lipoplasty system. 878.5040 Section 878.5040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...) Classification. Class II (special controls). Consensus standards and labeling restrictions. [63 FR 7705, Feb. 17...

  11. Numerical simulation and analysis of cavitation flows in a double suction centrifugal pump

    International Nuclear Information System (INIS)

    Meng, G; Tan, L; Cao, S L; Jian, W; Liu, W W; Jiang, D J

    2015-01-01

    Cavitation is an unsteady phenomenon, which is nearly inevitable in pumps. It would degrade the pump performance, generate vibrations and noises, and even erode pump flow passage components. The double suction centrifugal pump at design flow rate and large flow rate is numerically simulated using the k-ω turbulence model and the mass transport cavitation model. As a result, the calculated variation of pump head with pump inlet pressure agreed well with the experimental data. The results demonstrate that the numerical model and method can accurately predict the cavitation flows in a double suction centrifugal pump. The cavitation characteristics are analysed in great details. In addition, based on the calculation results, the reason that the plunge of pump head curve is revealed. It is found that the steep fall of pump head happens when the cavity reaches the blade to blade throat and the micro-vortex group appears at the back of the blade suction side. At the same time, this practice can provide guidance for the optimal design of double suction pumps

  12. External suction versus water seal after selective pulmonary resection for lung neoplasm: a systematic review.

    Directory of Open Access Journals (Sweden)

    Tong Qiu

    Full Text Available OBJECTIVE: To evaluate whether external suction is more advantageous than water seal in patients undergoing selective pulmonary resection (SPR for lung neoplasm. SUMMARY OF BACKGROUND DATA: Whether external suction should be routinely applied in postoperative chest drainage is still unclear, particularly for lung neoplasm patients. To most surgeons, the decision is based on their clinical experience. METHODS: Randomized control trials were selected. The participants were patients undergoing SPR with lung neoplasm. Lung volume reduction surgery and pneumothorax were excluded. Suction versus non-suction for the intervention. The primary outcome was the incidence of persistent air leak (PAL. The definition of PAL was air leak for more than 3-7 days. The secondary outcomes included air leak duration, time of drainage, postoperative hospital stay and the incidence of postoperative pneumothorax. Studies were identified from literature collections through screening. Bias was analyzed and meta-analysis was used. RESULTS: From the 1824 potentially relevant trials, 6 randomized control trials involving 676 patients were included. There was no difference between external suction and water seal in decreasing the incidence of PAL [95% confidence interval (CI 0.81-2.16; z = 1.10; P = 0.27]. Regarding secondary outcomes, there were no differences in time of drainage (95% CI-0.36-1.56, P = 0.22, postoperative hospital stay (95% CI -.31-.54, P = 0.87 or incidence of postoperative pneumothorax (95% CI 0.18-.02, P = 0.05 between external suction and water seal. CONCLUSIONS: For participants, no differences are identified in terms of PAL incidence, drainage time, length of postoperative hospital stay or incidence of postoperative pneumothorax between external suction and water seal. The bias analysis should be emphasized. To the limitations of the bias and methodological differences among the included studies, we have no recommendation on

  13. Assessment of Feasibility of Suction Pile/Anchor Installation and Pullout Testing through Field Tests

    Directory of Open Access Journals (Sweden)

    R. Vijaya

    2014-09-01

    Full Text Available Suction pile anchors are large cylindrical (inverted bucket type structure open at the bottom and closed at the top and largely used for mooring of offshore platforms, exploratory vessels etc. Prediction of the mooring capacity of suction piles is a critical issue faced by the design engineers and rational methods are required to produce reliable designs. Tests have been conducted in an existing natural pond within NIOT campus with the objective of developing methodology of deployment, design and logistics for suction pile installation and testing of mooring capacity under static pullout. Small size suction piles with varying diameters and lengths have been used in the tests. The tests have been carried out in the natural pond with constant water depth of 1.5 m with the top 1.5 m layer of bed comprising soft marine clay. It is found that pile geometry, aspect ratio and angle of pullout have a significant influence on the response to pullout. As angle of mooring load application changes from vertical to horizontal the reaction offered by the suction pile changes from skin friction to passive soil resistance. Resistance offered by the internal plug of soil is found to vary according to dimension of the anchor piles.

  14. 21 CFR 878.4780 - Powered suction pump.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A powered suction pump is a portable, AC-powered or compressed air-powered device intended to be used to remove infectious materials from wounds or fluids from a patient's airway or respiratory support system. The device may be used during surgery in the operating room or at the patient's bedside...

  15. Time management and nectar flow: flower handling and suction feeding in long-proboscid flies (Nemestrinidae: Prosoeca)

    Science.gov (United States)

    Karolyi, Florian; Morawetz, Linde; Colville, Jonathan F.; Handschuh, Stephan; Metscher, Brian D.; Krenn, Harald W.

    2013-11-01

    A well-developed suction pump in the head represents an important adaptation for nectar-feeding insects, such as Hymenoptera, Lepidoptera and Diptera. This pumping organ creates a pressure gradient along the proboscis, which is responsible for nectar uptake. The extremely elongated proboscis of the genus Prosoeca (Nemestrinidae) evolved as an adaptation to feeding from long, tubular flowers. According to the functional constraint hypothesis, nectar uptake through a disproportionately elongated, straw-like proboscis increases flower handling time and consequently lowers the energy intake rate. Due to the conspicuous length variation of the proboscis of Prosoeca, individuals with longer proboscides are hypothesised to have longer handling times. To test this hypothesis, we used field video analyses of flower-visiting behaviour, detailed examinations of the suction pump morphology and correlations of proboscis length with body length and suction pump dimensions. Using a biomechanical framework described for nectar-feeding Lepidoptera in relation to proboscis length and suction pump musculature, we describe and contrast the system in long-proboscid flies. Flies with longer proboscides spent significantly more time drinking from flowers. In addition, proboscis length and body length showed a positive allometric relationship. Furthermore, adaptations of the suction pump included an allometric relationship between proboscis length and suction pump muscle volume and a combination of two pumping organs. Overall, the study gives detailed insight into the adaptations required for long-proboscid nectar feeding, and comparisons with other nectar-sucking insects allow further considerations of the evolution of the suction pump in insects with sucking mouthparts.

  16. Half versus full vacuum suction drainage after modified radical mastectomy for breast cancer- a prospective randomized clinical trial[ISRCTN24484328

    Directory of Open Access Journals (Sweden)

    Singh JP

    2005-01-01

    Full Text Available Abstract Background Suction drains are routinely used after modified radical mastectomy and are an important factor contributing to increased hospital stay as the patients are often discharged only after their removal. Amongst various factors that influence the amount of postoperative drainage, the negative suction pressure applied to the drain has been reported to be of great significance. While a high negative suction pressure is expected to drain the collection and reduce the dead space promptly, it may also prevent the leaking lymphatics from closing and lead to increased drainage from the wound. Against this background a prospective randomized clinical study was conducted to compare the amount and duration of drainage between a half negative suction and full vacuum suction drainage in patients following modified radical mastectomy. The associated postoperative morbidity was also compared between the two groups. Methods 85 FNAC (fine needle aspiration cytology proven cases of locally advanced breast cancer were randomized. (Using randomly ordered sealed envelops, which were opened immediately before the closure of the wound in to 50 patients with full vacuum suction (pressure = 700 g/m2 and 35 cases in to half vacuum suction drainage (pressure = 350 g/m2 groups. The two groups were comparable in respect of age, weight, and technique of operation and extent of axillary dissection. Surgery was performed by the same surgical team comprising of five surgeons (two senior and three resident surgeons using a standardized technique with electrocautery. External compression dressing was provided over the axilla for first 48 hrs and following that patients were encouraged to do active and passive shoulder exercises. The outcomes measured were postoperative morbidity and the length of hospital stay. Statistical methods used: Descriptive studies were performed with SPSS version 10 and group characteristics were compared using student t-test. Results

  17. Effects of suction-dredging for cockles on non-target fauna in the Wadden Sea

    NARCIS (Netherlands)

    Hiddink, JG

    2003-01-01

    Suction dredging for cockles removes large cockles from tidal flats and may also cause mortality of non-target fauna and make the habitat less suitable for some species. This study examines whether suction dredging for cockles on tidal flats of the Dutch Wadden Sea had affected densities of

  18. Primary Total Knee Replacement: Is Suction a Portal of Infection?

    Science.gov (United States)

    Budnar, Vijaya M; Amirfeyz, Rouin; Ng, Michael; Bannister, Gordon C; Blom, Ashley W

    2009-01-01

    INTRODUCTION Pulsed lavage during a total knee replacement usually leaves a pool of fluid on the surgical drapes. It is common practice to suck away this fluid using the same suction device used intra-operatively. This could be a cause of direct wound contamination. We hypothesised that bacteria contaminate fluid that collects around the foot in total knee replacement surgery and that suction equipment could be a portal of contamination. We also hypothesised that bacterial count in the fluid is lower if chlorhexidine, rather than saline, is used in the pulsed lavage. PATIENTS AND METHODS Forty patients undergoing primary total knee replacement were divided into two groups. The first group had pulsed lavage with normal saline and the second with 0.05% chlorhexidine. RESULTS At the end of the operation, 20 ml of fluid, pooled on the surgical drapes was aspirated and cultured for bacterial growth. None of the fluid samples showed bacterial growth. CONCLUSIONS Suction device used peri-operatively during knee replacement is unlikely to be a cause of wound contamination. Pulsed lavage with normal saline is as effective as lavage with chlorhexidine. PMID:19335972

  19. Magnetohydrodynamic peristaltic motion of a Newtonian fluid through porous walls through suction and injection

    Science.gov (United States)

    Sivaiah, R.; Hemadri Reddy, R.

    2017-11-01

    In this paper, we investigate the peristaltic transport of a conducting Newtonian fluid bounded by permeable walls with suction and injection moving with constant velocity of the wave in the wave frame of reference under the consideration of long wavelength and low Reynolds number. The analytical solution for the velocity field, pressure gradient and the frictional force are obtained. The effect of suction/injection parameter, amplitude ratio and the permeability parameter including slip on the flow quantities are discussed graphically. It is found that the greater the suction/injection parameter, the smaller the pressure rise against the pump works. Further, the pressure rise increases with increasing Magnetic parameter.

  20. Present knowledge about Laboratory Testing of Axial Loading on Suction Caissons

    DEFF Research Database (Denmark)

    Manzotti, E.; Vaitkunaite, Evelina; Ibsen, Lars Bo

    Offshore wind turbines are increasing in both efficiency and size. More economical foundations for such light structures are under investigation, and suction caisson was shown to be particularly suitable for this purpose. In multi-pod foundation configuration, the overturning moment given by loads...... on the structure is resisted by push-pull loads on the vertical axis of each suction caisson. Relevant works where this situation is examined by means of laboratory testing are summarized in this article, then different conclusions are followed by discussion and comparison. In the initial theoretical section...

  1. Effects of vacuum suctioning and strategic drape tenting on oxygen concentration in a simulated surgical field.

    Science.gov (United States)

    Kung, Theodore A; Kong, Sarah W; Aliu, Oluseyi; Azizi, Jahan; Kai, Salim; Cederna, Paul S

    2016-02-01

    To investigate the isolated and combined effects of vacuum suctioning and strategic drape tenting on oxygen concentration in an experimental setting. Experimental. Clinical simulation center of a university-affiliated hospital. Mannequin simulation of a patient undergoing facial surgery under sedation anesthesia. Supplemental oxygen was delivered via nasal cannula. Vacuum suctioning and strategic drape tenting. The experimental trials entailed measuring oxygen concentration around the nasal cannula continuously either in the presence or absence of a standard operating room vacuum suction system and strategic tenting of surgical drapes. The primary outcome was the time required for oxygen concentration to reach 21%. In the control group (without suction or strategic tenting), a mean time of 180 seconds elapsed until the measured oxygen concentration reached 21% after cessation of oxygen delivery. Use of a vacuum suction device alone (110 seconds; P strategic tenting (110 seconds; P strategic tenting of surgical drapes has a theoretical benefit to decreasing the pooling of oxygen around the surgical site, further investigation is necessary before its routine use is recommended. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. A new suction mask to reduce leak during neonatal resuscitation: a manikin study.

    Science.gov (United States)

    Lorenz, Laila; Maxfield, Dominic A; Dawson, Jennifer A; Kamlin, C Omar F; McGrory, Lorraine; Thio, Marta; Donath, Susan M; Davis, Peter G

    2016-09-01

    Leak around the face mask is a common problem during neonatal resuscitation. A newly designed face mask using a suction system to enhance contact between the mask and the infant's face might reduce leak and improve neonatal resuscitation. The aim of the study is to determine whether leak is reduced using the suction mask (Resusi-sure mask) compared with a conventional mask (Laerdal Silicone mask) in a manikin model. Sixty participants from different professional categories (neonatal consultants, fellows, registrars, nurses, midwives and students) used each face mask in a random order to deliver 2 min of positive pressure ventilation to a manikin. Delivered airway pressures were measured using a pressure line. Inspiratory and expiratory flows were measured using a flow sensor, and expiratory tidal volumes and mask leaks were derived from these values. A median (IQR) leak of 12.1 (0.6-39.0)% was found with the conventional mask compared with 0.7 (0.2-4.6)% using the suction mask (p=0.002). 50% of the participants preferred to use the suction mask and 38% preferred to use the conventional mask. There was no correlation between leak and operator experience. A new neonatal face mask based on the suction system reduced leak in a manikin model. Clinical studies to test the safety and effectiveness of this mask are needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Development of Energy Efficiency Design Map based on acoustic resonance frequency of suction muffler in compressor

    International Nuclear Information System (INIS)

    Oh, Seungjae; Wang, Semyung; Cho, Sungman

    2015-01-01

    Highlights: • Development of Energy Efficiency Design Map. • Experimental validation of Energy Efficiency Design Map. • Suggestion regarding the Acoustically Supercharged Energy Efficiency. • Sensitivity analysis of the Energy Efficiency Ratio with respect to acoustic pressure. • Suggestion regarding the hybrid coupling method for acoustic analysis in compressor. - Abstract: The volumetric efficiency of the Internal Combustion (IC) engine and compressor can be increased by properly adjusting the acoustic resonance frequency of the suction muffler or the suction valve timing without any additional equipment or power source. This effect is known as acoustic supercharging. However, the energy efficiency has become more important than the volumetric efficiency because of the energy shortage issue and factors influencing consumers’ purchasing decisions. Therefore, methods for increasing the energy efficiency using the acoustic effect in the suction part of IC engine and compressor should be considered. In this study, a systematic method for improving the energy efficiency using the acoustic effect in the suction part of the compressor used in refrigerators and air conditioners was developed for the first time. This effect is named as the Acoustically Supercharged Energy Efficiency (ASEE). For the ASEE, first, a hybrid coupling method was suggested for the acoustical analysis in the suction part of the compressor. Next, an Energy Efficiency Design Map (EEDM) was proposed. This can serve as a design guide for suction mufflers in terms of the energy efficiency. Finally, sensitivity analyses of the Energy Efficiency Ratio (EER) and total massflow rate with respect to the acoustic pressure were conducted to identify the relationship between the acoustic pressure and the suction valve motion. This provides the physical background for the EEDM

  4. Final Report: Summary of Findings and Recommendations for Suction Devices for Management of Prehospital Combat Casualty Care Injuries

    Science.gov (United States)

    2017-11-13

    Airway Final Report: Summary of Findings and Recommendations for Suction Devices for Management of Prehospital Combat Casualty Care Injuries...Consumer Style Comparison Table of Suction Pump Devices ............................. 103 Appendix H – Web Links for Images for Consumer- Style ...0022 pg. 6 Executive Summary Suction is a critical component of airway management , which is the second leading cause of preventable

  5. COMPARISON OF THE EFFECTIVENESS OF TWO LEVELS OF SUCTION PRESSURE ON OXYGEN SATURATION IN PATIENTS WITH ENDOTRACHEAL TUBE

    Directory of Open Access Journals (Sweden)

    Muhaji

    2017-12-01

    Full Text Available Background: Endotracheal suctioning is one of the common supportive measures in intensive care units (ICU, which may be related to complications such as hypoxia. However, a questionable efficacy is still identified to choose suctioning pressure between 130 mmHg and 140 mmHg that is effective for patients with endotracheal tube. Objective: To compare the effectiveness of 130 mmHg and 140 mmHg suctioning pressure on oxygen saturation in patients with endotracheal tube. Methods: This research used a quasy experimental design with pretest and posttest group. The study was conducted from 31 January to 1 March 2017 in the Hospital of Panti Wilasa Citarum and Hospital of Roemani Muhammadiyah Semarang. There were 30 samples recruited using consecutive sampling, with 15 assigned in the 130 mmHg and 140 mmHg suctioning pressure group. Pulse oximetry was used to measure oxygen saturation. Paired t-test and Independent t-test were used for data analysis. Results: Findings showed that there was a statistically significant effect of 130 and 140 mmHg suctioning pressure on oxygen saturation in patients with ETT with p-value <0.05. There was a significant mean difference of oxygen saturation between 130 mmHg and 140 mmHg suctioning pressure group with p-value 0.004 (<0.05. The mean difference of oxygen saturation between both groups was 13.157. Conclusion: The 140 mmHg suctioning pressure is more effective compared with 130 mmHg suctioning pressure in increasing oxygen saturation in patients with ETT.

  6. Dynamic behaviour of suction caissons

    Energy Technology Data Exchange (ETDEWEB)

    Liingaard, M.

    2006-12-15

    Offshore wind energy is a promising source of energy in the near future, and is rapidly becoming competitive with other power generating technologies. The continuous improvement in wind turbine technology means that the wind turbines have increased tremendously in both size and performance during the last 25 years. In order to reduce the costs, the overall weight of the wind turbine components is minimized, which means that the wind turbine structures become more flexible and thus more sensitive to dynamic excitation. Since the first resonance frequency of the modern offshore wind turbines is close to the excitation frequencies of the rotor system, it is of outmost importance to be able to evaluate the resonance frequencies of the wind turbine structure accurately as the wind turbines increase in size. In order to achieve reliable responses of the wind turbine structure during working loads it is necessary to account for the possibilities of dynamic effects of the soil-structure interaction. The aim of this thesis is to evaluate the dynamic soil-structure interaction of foundations for offshore wind turbines, with the intention that the dynamic properties of the foundation can be properly included in a composite structure-foundation system. The work has been focused on one particular foundation type; the suction caisson. The frequency dependent stiffness (impedance) of the suction caisson has been investigated by means of a three-dimensional coupled Boundary Element/Finite Element model, where the soil is simplified as a homogenous linear viscoelastic material. The dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequencydependent coefficients corresponding to the different degrees of freedom. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been carried out for different combinations of the

  7. External Suction and Fluid Output in Chest Drains After Lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Neckelmann, Kirsten; Licht, Peter B

    2018-01-01

    influences the amount of fluid. METHODS: We randomly assigned (1:1) 106 patients who underwent lobectomy to either low (-5 cm H2O) or high (-20 cm H2O) external suction using an electronic chest drainage system. Only one chest drain was allowed, and we used strict algorithms for chest drain removal, which...... was delegated to staff nurses: air leakage less than 20 mL/min for 6 hours regardless of fluid output, provided it was serous. The primary end point was fluid output after 24 and 48 hours. RESULTS: Mean fluid output was significantly higher with high suction after both 24 (338 ± 265 mL versus 523 ± 215 m...

  8. Preliminary study of efficacy of cup suction in the correction of typical pectus excavatum.

    Science.gov (United States)

    Lopez, Manuel; Patoir, Arnaud; Costes, Frederic; Varlet, François; Barthelemy, Jean-Claude; Tiffet, Olivier

    2016-01-01

    This preliminary qualitative study evaluates the efficacy of cup suction in the correction of pectus excavatum (PE), and examines the place of this system as a strategic treatment and as an alternative to surgery. Between October 2011 and June 2014, a total of 84 patients (children and adult) presenting with PE were treated by cup suction, in our chest wall deformities unit. On first consultation, the patients with typical PE and with at least partial correction during the first application of cup suction and a maximal suction pressure for correction of less than 300 mbar (millibars) were included in this study. 11 patients were excluded from the present study as they presented with a complex carinatum/excavatum. The remaining 73 patients were divided into two groups: Group I, adult patients ≥ 18 year old, 17 patients. The mean age was 22.8 years old. Group II, pediatric patients cup suction, strengthening exercises, and clinical follow-up every two to three months. The evaluation criteria during, and on the completion of the trial were: depth of the PE, morbidity and treatment compliance. Partial and final results were evaluated by the patients, their parents, and doctor, using a qualitative scoring scale. A total of 73 patients presenting typical PE (symmetric in 52 cases and asymmetric in 21 cases) were treated by cup suction. The mean depth of PE was 23 mm (9-44). Of the 73 patients, one adult abandoned treatment and three children abandoned follow-up. The mean time of use of the device was 4h daily. At six months of treatment, the mean depth of PE was 9 mm (0-30) across all patients. 23 patients completed the treatment and exhibited flattening of the sternum. These patients were considered to have an excellent aesthetic result. The mean treatment duration to normal reshape was achieved at 10 months (4-21). The remaining patients are improving under continuing active treatment. The mean depth of PE in this group was 12 mm (4-30), after a mean treatment

  9. Vortex cavitation and oscillation in a double-suction volute pump

    International Nuclear Information System (INIS)

    Sato, T; Nagahara, T; Tanaka, K; Fuchiwaki, M; Shimizu, F

    2010-01-01

    In recent years, Computational Fluid Dynamics (CFD) codes have been utilized actively in the early part of the product development cycle. Numerical analysis models have also been developed rapidly and have added cavitation flow analysis functions peculiar to hydraulic machines, in which the flow analysis has been developed remarkably with high-precision and high-reliability. On the other hand, it is well known that three kinds of cavitation, such as vortex cavitation, reverse flow cavitation and cloud cavitation appear in a double-suction volute pump. We have much interest in a relationship among the cavitating flows, pump oscillation and noise. In this study, full 3D numerical simulations have been performed using a commercial code inside the pump from the inlet of suction duct to the outlet of delivery duct. The numerical model is based on a combination of multiphase flow equations with the truncated version of the Rayleigh-Plesset model predicting the complicated growth and collapse process of cavity bubbles. This study highlights especially the mechanism of vortex cavitation occurrence from the end of the suction duct in the pump and pump oscillation which causes cavitation noise from the pump. The experimental investigations have also been performed on the cavitating flow with flow visualization to evaluate the numerical results.

  10. Response of skirted suction caissons to monotonic lateral loading in saturated medium sand

    Science.gov (United States)

    Li, Da-yong; Zhang, Yu-kun; Feng, Ling-yun; Guo, Yan-xue

    2014-08-01

    Monotonic lateral load model tests were carried out on steel skirted suction caissons embedded in the saturated medium sand to study the bearing capacity. A three-dimensional continuum finite element model was developed with Z_SOIL software. The numerical model was calibrated against experimental results. Soil deformation and earth pressures on skirted caissons were investigated by using the finite element model to extend the model tests. It shows that the "skirted" structure can significantly increase the lateral capacity and limit the deflection, especially suitable for offshore wind turbines, compared with regular suction caissons without the "skirted" at the same load level. In addition, appropriate determination of rotation centers plays a crucial role in calculating the lateral capacity by using the analytical method. It was also found that the rotation center is related to dimensions of skirted suction caissons and loading process, i.e. the rotation center moves upwards with the increase of the "skirted" width and length; moreover, the rotation center moves downwards with the increase of loading and keeps constant when all the sand along the caisson's wall yields. It is so complex that we cannot simply determine its position like the regular suction caisson commonly with a specified position to the length ratio of the caisson.

  11. Supermarket refrigeration. Optimization of suction pressure in existing refrigerators; Supermarktkaelte. Saugdruck optimieren in Bestandskaelteanlagen

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Philipp; Mueller, Markus [Eckelmann AG, Wiesbaden (Germany)

    2012-06-15

    The new E*LDS firmware E*COP{sup +} from Eckelmann AG (Wiesbaden, Federal Republic of Germany) for the optimization of the suction pressure supplies a demand-oriented adaptation of the suction pressure. The new feature is ideal for an update of existing systems with thermostatic expansion valves. Using this update operators of supermarket operators may save about 10% energy with little effort.

  12. Natural convection boundary layer with suction and mass transfer in a porous medium

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1989-03-01

    The free convection boundary layer flow with simultaneous heat and mass transfer in a porous medium is studied when the boundary wall moves in its own plane with suction. The study also incorporates chemical reaction for the very simple model of a binary reaction with Arrhenius activation energy. For large suction asymptotic approximate solutions are obtained for the flow variables for various values of the activation energy. (author). 10 refs, 2 figs

  13. The effect of intraoral suction on oxygen-enriched surgical environments: a mechanism for reducing the risk of surgical fires.

    Science.gov (United States)

    VanCleave, Andrea M; Jones, James E; McGlothlin, James D; Saxen, Mark A; Sanders, Brian J; Vinson, LaQuia A

    2014-01-01

    In this study, a mechanical model was applied in order to replicate potential surgical fire conditions in an oxygen-enriched environment with and without high-volume suction typical for dental surgical applications. During 41 trials, 3 combustion events were measured: an audible pop, a visible flash of light, and full ignition. In at least 11 of 21 trials without suction, all 3 conditions were observed, sometimes with an extent of fire that required early termination of the experimental trial. By contrast, in 18 of 20 with-suction trials, ignition did not occur at all, and in the 2 cases where ignition did occur, the fire was qualitatively a much smaller, candle-like flame. Statistically comparing these 3 combustion events in the no-suction versus with-suction trials, ignition (P = .0005), audible pop (P = .0211), and flash (P = .0092) were all significantly more likely in the no-suction condition. These results suggest a possible significant and new element to be added to existing surgical fire safety protocols toward making surgical fires the "never-events" they should be.

  14. Endoscopic en bloc resection of an exophytic gastrointestinal stromal tumor with suction excavation technique

    Science.gov (United States)

    Choi, Hyuk Soon; Chun, Hoon Jai; Kim, Kyoung-Oh; Kim, Eun Sun; Keum, Bora; Jeen, Yoon-Tae; Lee, Hong Sik; Kim, Chang Duck

    2016-01-01

    Here, we report the first successful endoscopic resection of an exophytic gastrointestinal stromal tumor (GIST) using a novel perforation-free suction excavation technique. A 49-year-old woman presented for further management of a gastric subepithelial tumor on the lesser curvature of the lower body, originally detected via routine upper gastrointestinal endoscopy. Abdominal computed tomography and endoscopic ultrasound showed a 4-cm extraluminally protruding mass originating from the muscularis propria layer. The patient firmly refused surgical resection owing to potential cardiac problems, and informed consent was obtained for endoscopic removal. Careful dissection and suction of the tumor was repeated until successful extraction was achieved without serosal injury. We named this procedure the suction excavation technique. The tumor’s dimensions were 3.5 cm × 2.8 cm × 2.5 cm. The tumor was positive for C-KIT and CD34 by immunohistochemical staining. The mitotic count was 6/50 high-power fields. The patient was followed for 5 years without tumor recurrence. This case demonstrated the use of endoscopic resection of an exophytic GIST using the suction excavation technique as a potential therapy without surgical resection. PMID:27340363

  15. Theoretical Analysis of Effects of Wall Suction on Entropy Generation Rate in Laminar Condensate Layer on Horizontal Tube

    Directory of Open Access Journals (Sweden)

    Tong-Bou Chang

    2014-01-01

    Full Text Available The effects of wall suction on the entropy generation rate in a two-dimensional steady film condensation flow on a horizontal tube are investigated theoretically. In analyzing the liquid flow, the effects of both the gravitational force and the viscous force are taken into account. In addition, a film thickness reduction ratio, Sf, is introduced to evaluate the effect of wall suction on the thickness of the condensate layer. The analytical results show that, the entropy generation rate depends on the Jakob number Ja, the Rayleigh number Ra, the Brinkman number Br, the dimensionless temperature difference ψ, and the wall suction parameter Sw. In addition, it is shown that in the absence of wall suction, a closed-form correlation for the Nusselt number can be derived. Finally, it is shown that the dimensionless entropy generation due to heat transfer, NT, increases with an increasing suction parameter Sw, whereas the dimensionless entropy generation due to liquid film flow friction, NF, decreases.

  16. LES-based characterization of a suction and oscillatory blowing fluidic actuator

    Science.gov (United States)

    Kim, Jeonglae; Moin, Parviz

    2015-11-01

    Recently, a novel fluidic actuator using steady suction and oscillatory blowing was developed for control of turbulent flows. The suction and oscillatory blowing (SaOB) actuator combines steady suction and pulsed oscillatory blowing into a single device. The actuation is based upon a self-sustained mechanism of confined jets and does not require any moving parts. The control output is determined by a pressure source and the geometric details, and no additional input is needed. While its basic mechanisms have been investigated to some extent, detailed characteristics of internal turbulent flows are not well understood. In this study, internal flows of the SaOB actuator are simulated using large-eddy simulation (LES). Flow characteristics within the actuator are described in detail for a better understanding of the physical mechanisms and improving the actuator design. LES predicts the self-sustained oscillations of the turbulent jet. Switching frequency, maximum velocity at the actuator outlets, and wall pressure distribution are in good agreement with the experimental measurements. The computational results are used to develop simplified boundary conditions for numerical experiments of active flow control. Supported by the Boeing company.

  17. The application of suction caisson technology to offshore wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-09-15

    A mathematical model describing the behaviour of caisson foundations for offshore wind turbines has been developed. The model has been verified and calibrated through laboratory and field work. Simultaneously, conceptual designs of wind turbine foundations incorporating suction caissons were studied using the same model. It was concluded that much of the seabed around Britain is well suited to the use of caissons and monopod and quadropod structures are superior to tripods. Although suction caissons are vulnerable to scour, rock dumping can largely eliminate this potential problem. The next phase will be to install a fully instrumented full-scale prototype to monitor the effects of wind and waves. The main contractor was SLP Engineering Limited and about 75 per cent of the funding came from the DTI.

  18. Fluid Model of Sliding Suction Cup of Wall-climbing Robots

    Directory of Open Access Journals (Sweden)

    Fu Zhuang

    2008-11-01

    Full Text Available The adhering capability, one of the most important performance indexes of wall-climbing robots(WCRs, should be taken into account when a WCR is designed. This paper proposes a novel approach for investigating the adhering characteristics of the sliding suction cup (SSCs using fluid network theory to enhance the adhering capability of WCRs. The fluid models of the SSCs of two WCRs are developed and equivalent circuits in three cases are presented. The dynamic responses of negative pressure in SSCs are obtained and validated by a set of experiments. It indicated that the theoretical analysis is reasonable and can give some valuable design criteria on the structure parameters of SSCs and control strategies of suction force of SSCs.

  19. The effects of suction and pin/lock suspension systems on transtibial amputees' gait performance.

    Directory of Open Access Journals (Sweden)

    Hossein Gholizadeh

    Full Text Available BACKGROUND: The suction sockets that are commonly prescribed for transtibial amputees are believed to provide a better suspension than the pin/lock systems. Nevertheless, their effect on amputees' gait performance has not yet been fully investigated. The main intention of this study was to understand the potential effects of the Seal-in (suction and the Dermo (pin/lock suspension systems on amputees' gait performance. METHODOLOGY/PRINCIPAL FINDINGS: Ten unilateral transtibial amputees participated in this prospective study, and two prostheses were fabricated for each of them. A three-dimensional motion analysis system was used to evaluate the temporal-spatial, kinematics and kinetics variables during normal walking. We also asked the participants to complete some part of Prosthesis Evaluation Questionnaire (PEQ regarding their satisfaction and problems with both systems. The results revealed that there was more symmetry in temporal-spatial parameters between the prosthetic and sound limbs using the suction system. However, the difference between two systems was not significant (p<0.05. Evaluation of kinetic data and the subjects' feedback showed that the participants had more confidence using the suction socket and the sockets were more fit for walking. Nevertheless, the participants had more complaints with this system due to the difficulty in donning and doffing. CONCLUSION: It can be concluded that even though the suction socket could create better suspension, fit, and gait performance, overall satisfaction was higher with the pin/lock system due to easy donning and doffing of the prosthesis. TRIAL REGISTRATION: irct.ir IRCT2014012816395N1.

  20. Numerical Study of Piping Limits for Suction Installation of Offshore Skirted Foundations an Anchors in Layered Sand

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Thilsted, C. L.

    2010-01-01

    Skirted foundations and anchors have proved to be competitive solutions for various types of fixed offshore platforms, subsea systems and an attractive foundation alternative for offshore wind turbines. One main design challenge for skirted structures in sand is to penetrate the skirted deep enough...... to obtain the required capacity. In order to overcome the high penetration resistance in sand suction assisted penetration is needed. Suction installation may cause the formation of piping channels, which break down the hydraulic seal and prevent further installation. This paper presents a numerical study...... of failure limits during suction installation in respect to both homogenous and layered soil profile. A numerical flow analysis is performed to determine the hydraulic gradients developing in response to the suction applied, and the results are presented as simple closed form solutions useful for evaluation...

  1. Reduction of the suction losses through reed valves in hermetic reciprocating compressors using a magnet coil

    Science.gov (United States)

    Hopfgartner, J.; Posch, S.; Zuber, B.; Almbauer, R.; Krischan, K.; Stangl, S.

    2017-08-01

    Reed valves are widely used in hermetic reciprocating compressors and are responsible for a large part of the thermodynamic losses. Especially, the suction valve, which is opened nearly during the whole suction stroke, has a big potential for improvement. Usually, suction valves are opened only by vacuum created by the moving piston and should be closed before the compression stroke starts to avoid a reversed mass-flow through the valve. Therefore, the valves are prestressed, which results on the other hand in a higher flow resistance. In this work, a suction valve is investigated, which is not closed by the preload of the valve but by an electromagnetic coil located in the suction muffler neck. Shortly before the piston reaches its bottom dead centre, voltage is applied to the coil and a magnetic force is generated which pulls the valve shut. Thereby, the flow resistance through the valve can be reduced by changing the preload on the reed valve because it is no longer needed to close the valve. The investigation of this adapted valve and the electromagnetic coil is firstly done by numerical simulations including fluid structure interactions of the reed valves of a reciprocating compressor and secondly by experiments made on a calorimeter test bench.

  2. Influence of saturation degree and role of suction in unsaturated soils behaviour: application to liquefaction

    Directory of Open Access Journals (Sweden)

    Vernay Mathilde

    2016-01-01

    Full Text Available The effect of the pore fluid compressibility on liquefaction has been studied by various authors. But few papers have been published about the role of suction in cyclic behavior of unsaturated soils. Most of these works use Skempton coefficient B as a reference in terms of saturation degree to analyze their results. The use of B in experimental conditions is convenient, but is not accurate when studying liquefaction behavior, since effects of suction are neglected. In this paper, the influence of saturation degree on mechanical behavior of a soil under dynamic loads is studied. Cyclic undrained triaxial tests were performed on sand samples, under various levels of saturation. Soil-water characteristic curve was used, in order to study influence of suction. The first results confirm that when the degree of saturation decreases, the resistance increases. Initial positive suction tends to stiffen the soil. It also appears that the presence of air delays the occurrence of liquefaction, but doesn’t prevent it. Indeed, liquefaction is observed, whether the soil is saturated or not.

  3. Gravity separation of pericardial fat in cardiotomy suction blood: an in vitro model.

    Science.gov (United States)

    Kinard, M Rhett; Shackelford, Anthony G; Sistino, Joseph J

    2009-06-01

    Fat emboli generated during cardiac surgery have been shown to cause neurologic complications in patients postoperatively. Cardiotomy suction has been known to be a large generator of emboli. This study will examine the efficacy of a separation technique in which the cardiotomy suction blood is stored in a cardiotomy reservoir for various time intervals to allow spontaneous separation of fat from blood by density. Soybean oil was added to heparinized porcine blood to simulate the blood of a patient with hypertriglyceridemia (> 150 mg/dL). Roller pump suction was used to transfer the room temperature blood into the cardiotomy reservoir. Blood was removed from the reservoir in 200-mL aliquots at 0, 15, 30 45, and 60 minutes. Samples were taken at each interval and centrifuged to facilitate further separation of liquid fat. Fat content in each sample was determined by a point-of-care triglyceride analyzer. Three trials were conducted for a total of 30 samples. The 0-minute group was considered a baseline and was compared to the other four times. Fat concentration was reduced significantly in the 45- and 60-minute groups compared to the 0-, 15-, and 30-minute groups (p Gravity separation of cardiotomy suction blood is effective; however, it may require retention of blood for more time than is clinically acceptable during a routing coronary artery bypass graft surgery.

  4. 78 FR 20316 - Final Issuance of General NPDES Permits (GP) for Small Suction Dredges in Idaho

    Science.gov (United States)

    2013-04-04

    ... System (NPDES) General Permit (IDG-37-0000) to placer mining operations in Idaho for small suction... Small Suction Dredges in Idaho AGENCY: Environmental Protection Agency, Region 10. ACTION: Final notice... significant economic impact on a substantial number of small entities.'' EPA has concluded that NPDES general...

  5. Development of advanced stability theory suction prediction techniques for laminar flow control. [on swept wings

    Science.gov (United States)

    Srokowski, A. J.

    1978-01-01

    The problem of obtaining accurate estimates of suction requirements on swept laminar flow control wings was discussed. A fast accurate computer code developed to predict suction requirements by integrating disturbance amplification rates was described. Assumptions and approximations used in the present computer code are examined in light of flow conditions on the swept wing which may limit their validity.

  6. A Report on Deliverable Three: Determine a Standard Performance Test for Military Suction Device Use

    Science.gov (United States)

    2017-09-20

    evaluating device suction while either wetted or completely immersed is highly important to predict performance in battlefield scenarios. Summary...mechanical, electrical, and environmental. OBJECTIVE: Research and review current test methods outlined in ISO 10079 and published journal articles...of contemporary oropharyngeal suction. The American journal of emergency medicine 17, 611- 613 (1999). 4. Hodgetts, T., Mahoney, P., Evans, G

  7. The use of IV-tubing as a closed-suction drainage system during neurosurgical cases in Tanzania.

    Science.gov (United States)

    Bonfield, Christopher M; Shabani, Hamisi K; Kanumba, Emmanuel S; Ellegala, Dilantha B; Nicholas, Joyce

    2013-01-01

    Commercial closed-suctions drainage systems are commonly used in the United States and many other countries for use in neurosurgical cases. However, in Tanzania and other developing nations with fewer resources, these are not available. This report explores another option for a closed-system drainage system utilizing inexpensive supplies found commonly in hospitals around the world. Sterile IV-tubing is cut, inserted into the wound, and brought out through an adjacent puncture incision. For suction, an empty plastic bottle can be attached to the tubing. The IV-tubing closed-suction drainage system was applied in both cranial and spinal neurosurgical procedures, including as subdural, subgaleal, epidural, and suprafacial drains. It maintained suction and was an adequate substitute when commercial drains are unavailable. This report illustrates how sterile IV-tubing can be adapted for use as a closed-drainage system. It utilizes inexpensive supplies commonly found in many hospitals throughout the world and can be applied to both cranial and spinal neurosurgical procedures.

  8. Deriving the suction stress of unsaturated soils from water retention curve, based on wetted surface area in pores

    Science.gov (United States)

    Greco, Roberto; Gargano, Rudy

    2016-04-01

    The evaluation of suction stress in unsaturated soils has important implications in several practical applications. Suction stress affects soil aggregate stability and soil erosion. Furthermore, the equilibrium of shallow unsaturated soil deposits along steep slopes is often possible only thanks to the contribution of suction to soil effective stress. Experimental evidence, as well as theoretical arguments, shows that suction stress is a nonlinear function of matric suction. The relationship expressing the dependence of suction stress on soil matric suction is usually indicated as Soil Stress Characteristic Curve (SSCC). In this study, a novel equation for the evaluation of the suction stress of an unsaturated soil is proposed, assuming that the exchange of stress between soil water and solid particles occurs only through the part of the surface of the solid particles which is in direct contact with water. The proposed equation, based only upon geometric considerations related to soil pore-size distribution, allows to easily derive the SSCC from the water retention curve (SWRC), with the assignment of two additional parameters. The first parameter, representing the projection of the external surface area of the soil over a generic plane surface, can be reasonably estimated from the residual water content of the soil. The second parameter, indicated as H0, is the water potential, below which adsorption significantly contributes to water retention. For the experimental verification of the proposed approach such a parameter is considered as a fitting parameter. The proposed equation is applied to the interpretation of suction stress experimental data, taken from the literature, spanning over a wide range of soil textures. The obtained results show that in all cases the proposed relationships closely reproduces the experimental data, performing better than other currently used expressions. The obtained results also show that the adopted values of the parameter H0

  9. Experimental study on occurrence-time ratio measurements of air entrainment in a suction sump

    International Nuclear Information System (INIS)

    Inagaki, K; Funaki, J; Hirata, K

    2009-01-01

    In order to get accurate measurements of air entrainment in a suction sump, we design some new simple bubble sensors, which can detect the existence of air bubbles inside a suction pipe with no disturbances by the sensors and with a fine spatial resolution. We force on an intermittency factor γ, that is, an occurrence-time ratio of the air entrainment, and compare the result by the present sensor with those by conventional two methods; namely, visual and auditory ones. As a result, we show the criteria which specify lower-accuracy conditions in the conventional methods. By the visual method, the accuracy of the γ becomes low, when γ is less than 0.05. By the auditory method, the accuracy of γ becomes low, when the submergence depth S of the suction pipe is close to the critical one S c .

  10. Improved Suction Technique for the Characterization of Construction Materials

    DEFF Research Database (Denmark)

    Thygesen, Lisbeth Garbrecht; Hansen, Kurt Kielsgaard

    2007-01-01

    The suction technique is a method from soil science that is used for the study of moisture storage capacity in porous construction materials at high relative humidity levels (above approximately 93%). The samples to be studied are placed in a pressurized container (an extractor) on a water...

  11. Radon Sub-slab Suctioning System Integrated in Insulating Layer

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2013-01-01

    This poster presents a new radon sub-slab suctioning system. This system makes use of a grid of horizontal pressurised air ducts located within the lower part of the rigid insulation layer of the ground floor slab. For this purpose a new system of prefabricated lightweight elements is introduced...

  12. Alternative Shape of Suction Caisson to Reduce Risk of Buckling under high Pressure

    DEFF Research Database (Denmark)

    Madsen, Søren; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    2013-01-01

    Using large suction caissons for offshore wind turbines is an upcoming technology also referred to as bucket foundations. During operation the bucket foundation is loaded by a large overturning moment from the wind turbine and the wave loads. However, during installation the bucket is loaded...... cylindrical monopod foundation made of steel. In this paper, an alternative design/shape of the suction caisson, having a smaller risk of buckling under high pressure is presented. The risk of structural buckling is addressed using numerical methods to determine the buckling pressures of the re...

  13. A Constitutive Model for Unsaturated soils based on a Compressibility Framework dependent on Suction and Degree of Saturation

    Directory of Open Access Journals (Sweden)

    Sitarenios Panagiotis

    2016-01-01

    Full Text Available The Modified Cam Clay model is extended to account for the behaviour of unsaturated soils using Bishop’s stress. To describe the Loading – Collapse behaviour, the model incorporates a compressibility framework with suction and degree of saturation dependent compression lines. For simplicity, the present paper describes the model in the triaxial stress space with characteristic simulations of constant suction compression and triaxial tests, as well as wetting tests. The model reproduces an evolving post yield compressibility under constant suction compression, and thus, can adequately describe a maximum of collapse.

  14. Numerical Investigation of Wall Cooling and Suction Effects on Supersonic Flat-Plate Boundary Layer Transition Using Large Eddy Simulation

    Directory of Open Access Journals (Sweden)

    Suozhu Wang

    2015-02-01

    Full Text Available Reducing friction resistance and aerodynamic heating has important engineering significance to improve the performances of super/hypersonic aircraft, so the purpose of transition control and turbulent drag reduction becomes one of the cutting edges in turbulence research. In order to investigate the influences of wall cooling and suction on the transition process and fully developed turbulence, the large eddy simulation of spatially evolving supersonic boundary layer transition over a flat-plate with freestream Mach number 4.5 at different wall temperature and suction intensity is performed in the present work. It is found that the wall cooling and suction are capable of changing the mean velocity profile within the boundary layer and improving the stability of the flow field, thus delaying the onset of the spatial transition process. The transition control will become more effective as the wall temperature decreases, while there is an optimal wall suction intensity under the given conditions. Moreover, the development of large-scale coherent structures can be suppressed effectively via wall cooling, but wall suction has no influence.

  15. Analysis of Infiltration-Suction Response in Unsaturated Residual Soil Slope in Gelugor, Penang

    Science.gov (United States)

    Ashraf Mohamad Ismail, Mohd; Hasliza Hamzah, Nur; Min, Ng Soon; Hazreek Zainal Abidin, Mohd; Tajudin, Saiful Azhar Ahmad; Madun, Aziman

    2018-04-01

    Rainfall infiltration on residual soil slope may impair slope stability by altering the pore-water pressure in the soil. A study has been carried out on unsaturated residual soil slope in Gelugor, Penang to determine the changes in matric suction of residual soils at different depth due to rainwater infiltration. The sequence of this study includes the site investigation, field instrumentation, laboratory experiment and numerical modeling. Void ratio and porosity of soil were found to be decreasing with depth while the bulk density and dry density of soil increased due to lower porosity of soil at greater depth. Soil infiltration rate and matric suction of all depths decrease with the increase of volumetric water content as well as the degree of saturation. Numerical modeling was used to verify and predict the relationship between infiltration-suction response and degree of saturation. Numerical models can be used to integrate the rainfall scenarios into quantitative landslide hazard assessments. Thus, development plans and mitigation measures can be designed for estimated impacts from hazard assessments based on collected data.

  16. Frequency Response of Near-Wall Coherent Structures to Localized Periodic Blowing and Suction in Turbulent Boundary Layer

    International Nuclear Information System (INIS)

    Jian-Hua, Liu; Nan, Jiang

    2008-01-01

    We experimentally investigate the frequency response of near-wall coherent structures to localized periodic blowing and suction through a spanwise slot in a turbulent boundary layer by changing the frequency of periodic disturbance at similar velocities of free stream. The effects of blowing and suction disturbance on energy redistribution, turbulent intensity u' rms + , over y + and waveforms of phase-averaged velocity during sweeping process are respectively discussed under three frequencies of periodic blowing and suction in near-wall region of turbulent boundary layer, compared with those in a standard turbulent boundary layer. The most effective disturbance frequency is figured out in this system. (fundamental areas of phenomenology (including applications))

  17. MHD flow over a permeable stretching/shrinking sheet of a nanofluid with suction/injection

    Directory of Open Access Journals (Sweden)

    Sandeep Naramgari

    2016-06-01

    Full Text Available In this study we analyzed the influence of thermal radiation and chemical reaction on two dimensional steady magnetohydrodynamic flow of a nanofluid past a permeable stretching/shrinking sheet in the presence of suction/injection. We considered nanofluid volume fraction on the boundary is submissive controlled, which makes the present study entirely different from earlier studies and physically more realistic. The equations governing the flow are solved numerically. Effects of non-dimensional governing parameters on velocity, temperature and concentration profiles are discussed and presented through graphs. Also, coefficient of skin friction and local Nusselt number is investigated for stretching/shrinking and suction/injection cases separately and presented through tables. Comparisons with existed results are presented. Present results have an excellent agreement with the existed studies under some special assumptions. Results indicate that the enhancement in Brownian motion and thermophoresis parameters depreciates the nanoparticle concentration and increases the mass transfer rate. Dual solutions exist only for certain range of stretching/shrinking and suction/injection parameters.

  18. Tube suction test for evaluating durability of cementitiously stabilized soils.

    Science.gov (United States)

    2011-06-01

    In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (F-T/W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moisture ...

  19. Tube suction test for evaluating durability of cementitiously stabilized soils.

    Science.gov (United States)

    2011-06-01

    In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (FT/ : W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moistur...

  20. Safety System for Controlling Fluid Flow into a Suction Line

    Science.gov (United States)

    England, John Dwight (Inventor); Kelley, Anthony R. (Inventor); Cronise, Raymond J. (Inventor)

    2018-01-01

    A safety system includes a sleeve fitted within a pool's suction line at its inlet. The sleeve terminates with a plate that resides within the suction line. The plate has holes formed therethrough. A housing defining distinct channels is fitted in the sleeve so that the distinct channels lie within the sleeve. Each of the distinct channels has a first opening on one end thereof and a second opening on another end thereof. The second openings reside in the sleeve. The first openings are in fluid communication with the water in the pool, and are distributed around a periphery of an area of the housing that prevents coverage of all the first openings when a human interacts therewith. A first sensor is coupled to the sleeve to sense pressure therein, and a second pressure sensor is coupled to the plate to sense pressure in one of the plates' holes.

  1. Vapor pressure lowering effects due to salinity and suction pressure in the depletion of vapor-dominated geothermal reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Battistelli, A. [Aquater S.p.A., Pisa (Italy); Calore, C. [Istituto Internazionale per le Ricerche Geotermiche-CNR, Pisa (Italy); Pruess, K. [Lawrence Berkeley Lab., Berkeley, CA (United States)

    1995-03-01

    The equation-of-state module able to handle saline brines with non-condensible gas, developed for the TOUGH2 simulator, has been improved to include vapor pressure lowering (VPL) due to suction pressure as represented by Kelvin`s equation. In this equation the effects of salt are considered whereas those of non-condensible gas have currently been neglected. Numerical simulations of fluid production from tight matrix blocks have been performed to evaluate the impact of VPL effects due to salinity and suction pressure on the depletion behaviour of vapor-dominated geothermal reservoirs. Previous studies performed neglected VPL due to suction pressure showed that for initial NaCl mass fractions above threshold values, {open_quotes}sealing{close_quotes} of the block occurs and large amounts of liquid fluid may not be recovered. On the other hand, below the threshold value the matrix block dries out due to fluid production. The inclusion of VPL due to suction pressure does not allow complete vaporization of the liquid phase. As a result, the threshold NaCl concentration above which sealing of the matrix block occurs is increased. Above the {open_quotes}critical{close_quotes} NaCl concentration, block depletion behaviour with and without the VPL due to suction pressure is almost identical, as liquid phase saturation remains high even after long production times. As the VPL due to suction pressure depends mainly on capillary pressure, the shape of capillary pressure functions used in numerical simulations is important in determining VPL effects on block depletion.

  2. Dynamic stiffness of suction caissons - torsion, sliding and rocking

    Energy Technology Data Exchange (ETDEWEB)

    Ibsen, Lars Bo; Liingaard, M.; Andersen, Lars

    2006-12-15

    This report concerns the dynamic soil-structure interaction of steel suction caissons applied as foundations for offshore wind turbines. An emphasis is put on torsional vibrations and coupled sliding/rocking motion, and the influence of the foundation geometry and the properties of the surrounding soil is examined. The soil is simplified as a homogenous linear viscoelastic material and the dynamic stiffness of the suction caisson is expressed in terms of dimensionless frequency-dependent coefficients corresponding to the different degrees of freedom. The dynamic stiffness coefficients for the skirted foundation are evaluated by means of a three-dimensional coupled boundary element/finite element model. Comparisons with known analytical and numerical solutions indicate that the static and dynamic behaviour of the foundation are predicted accurately with the applied model. The analysis has been carried out for different combinations of the skirt length and the Poisson's ratio of the subsoil. Finally, the high-frequency impedance has been determined for future use in lumped-parameter models of wind turbine foundations in aero-elastic codes. (au)

  3. Timer switch to convert suction apparatus for negative pressure wound therapy application

    Directory of Open Access Journals (Sweden)

    Surath Amarnath

    2014-01-01

    Full Text Available Background: Negative pressure wound therapy (NPWT is an established modality in the treatment of chronic wounds, open fractures, and post-operative wound problems. This method has not been widely used due to the high cost of equipment and consumables. This study demonstrates an indigenously developed apparatus which gives comparable results at a fraction of the cost. Readily available materials are used for the air-tight dressing. Materials and Methods: Equipment consists of suction apparatus with adjustable pressure valve set to a pressure 125-150 mmHg. An electronic timer switch with a sequential working time of 5 min and a standby time of 3 min provides the required intermittent negative pressure. Readily available materials such as polyvinyl alcohol sponge, suction drains and steridrapes were used to provide an air tight wound cover. Results: A total of 90 cases underwent 262 NPWT applications from 2009 to 2014. This series, comprised of 30 open fractures, 21 post-operative and 39 chronic wounds. The wound healing rate in our study was comparable to other published studies using NPWT. Conclusion: The addition of electronic timer switch will convert a suction apparatus into NPWT machine, and the results are equally effective compared to more expensive counter parts. The use of indigenous dressing materials reduces the cost significantly.

  4. A Comparison of delO18 Composition of Water Extracted from Suction Lysimeters, Centrifugation, and Azeotropic Distillation

    Science.gov (United States)

    Figueroa, A.; Tindall, J. A.; Friedel, M. J.

    2005-12-01

    Concentration of delO18 in water samples extracted by suction lysimeters is compared to samples obtained by methods of centrifugation and azeotropic distillation. Intact soil cores (30 cm diameter by 40 cm height) were extracted from two different sites. Site 1 was rapid infiltration basin number 50, near Altamonte Springs in Seminole County, Florida on properties belonging to the Walt Disney World Resort Complex. Site 2 was the Missouri Management System Evaluation Area (MSEA) near Centralia in Boone County, Missouri. The delO18 water was analyzed on a mass spectrophotometer. Potassium Bromide (KBr) was also used as a tracer and analyzed by ion chromatography. A portion of the data obtained was modeled using CXTFIT. Water collected by centrifugation and azeotropic distillation data were about 2-5% more negative than that collected by suction lysimeter values from the Florida (sandy) soil and about 5-7 % more negative from the Missouri (well structured clay) soil. Results indicate that the majority of soil water in well structured soil is strongly bound to soil grain surfaces and is not easily sampled by suction lysimeters. Also, it is plausible that evaporation caused some delO18 enrichment in the suction lysimeters. Suction lysimeters preferentially sampled water held at lower matric potentials, which may not represent total soil water. In cases where a sufficient volume of water has passed through the soil profile and displaced all previous pore water, suction lysimeters will however collect a representative sample of all the water at that depth interval. It is suggested that for stable isotope studies monitoring precipitation and soil water, suction lysimeters be installed at shallow depths (10 cm). Samples should also be coordinated with precipitation events. The CXTFIT program worked well for Florida soils (a more homogeneous sand), but gave poor performance for Missouri soils (well structured clays) except for deeper depths where clay structure was less

  5. Thopaz Portable Suction Systems in Thoracic Surgery: An end user assessment and feedback in a tertiary unit

    Directory of Open Access Journals (Sweden)

    Cantlin Teresa

    2011-04-01

    Full Text Available Abstract Background Thoracic surgical patients have chest drains inserted to enable re-expansion of lungs, to clear contents from the pleural cavity which sometimes require negative suction. Suction impedes mobility, may have variable suction delivery and increases risk of infection. Assessment of air-leak in conventional drains is not scientific and is subjective. Thopaz chest drain system is a portable suction unit which allows mobilization of the patient, with scientific digital flow recordings and an in built alarm system. Methods We evaluated the utility, staff and patient feedback of this device in a pilot evaluation in a regional thoracic unit in a structured format over a period of two months. Staff responses were graded on a scale of 1 to 6 [1 Excellent to 6 Poor]. Results 120 patients who underwent elective bullectomy/pleurectomy, VATS lung biopsies, VATS metastectomy and lung resections were evaluated. The staff feedback forms were positive. The staff liked the system as it was more scientific and accurately recordable. It made nursing and physiotherapy easier as they could mobilise patients early. The patients liked the compact design, weightlessness and the silence. It enabled mobilisation of the patients and scientific removal of chest drain. Conclusions Thopaz digital suction units were found to be user friendly and were liked by the staff and patients. The staff feedback stated the devices to be objective and scientific in making decisions about removal and enabled mobilisation.

  6. Microsatellite marker analysis of peach-potato aphids (Myzus persicae, Homoptera: Aphididae) from Scottish suction traps.

    Science.gov (United States)

    Malloch, G; Highet, F; Kasprowicz, L; Pickup, J; Neilson, R; Fenton, B

    2006-12-01

    The peach-potato aphid Myzus persicae (Sulzer) is an important vector of plant viruses. A network of suction traps collects aerial samples of this aphid in order to monitor and help predict its spatial distribution and likely impact on virus transmission in crops. A suction trap catch is thought to be a good representation of the total aphid pool. Sensitive molecular markers have been developed that determine the genetic composition of the M. persicae population. In Scotland, UK, these were applied to field collections revealing a limited number of clones. Molecular markers are less successful when applied to specimens that have been preserved in an ethanol-based trap fluid designed to preserve morphology. An assessment of different DNA extraction and PCR techniques is presented and the most efficient are used to analyse M. persicae specimens caught in the Dundee suction trap in 2001, a year when exceptionally high numbers were caught. The results reveal that the majority of the M. persicae caught belonged to two highly insecticide resistant clones. In addition, it was possible to compare the relative frequencies of genotypes caught in the trap with those collected at insecticide treated and untreated field sites in the vicinity. These results indicate that, in addition to suction trap data, the ability to sample field sites provides valuable early warning data which have implications for pest control and virus management strategies.

  7. Temperature measurement in WTE boilers using suction pyrometers.

    Science.gov (United States)

    Rinaldi, Fabio; Najafi, Behzad

    2013-11-15

    The temperature of the flue-gas in the post combustion zone of a waste to energy (WTE) plant has to be maintained within a fairly narrow range of values, the minimum of which is prescribed by the European Waste Directive 2000/76/CE, whereas the maximum value must be such as to ensure the preservation of the materials and the energy efficiency of the plant. A high degree of accuracy in measuring and controlling the aforementioned temperature is therefore required. In almost the totality of WTE plants this measurement process is carried out by using practical industrial thermometers, such as bare thermocouples and infrared radiation (IR) pyrometers, even if affected by different physical contributions which can make the gas temperature measurements incorrect. The objective of this paper is to analyze errors and uncertainties that can arise when using a bare thermocouple or an IR pyrometer in a WTE plant and to provide a method for the in situ calibration of these industrial sensors through the use of suction pyrometers. The paper describes principle of operation, design, and uncertainty contributions of suction pyrometers, it also provides the best estimation of the flue-gas temperature in the post combustion zone of a WTE plant and the estimation of its expanded uncertainty.

  8. Temperature Measurement in WTE Boilers Using Suction Pyrometers

    Directory of Open Access Journals (Sweden)

    Fabio Rinaldi

    2013-11-01

    Full Text Available The temperature of the flue-gas in the post combustion zone of a waste to energy (WTE plant has to be maintained within a fairly narrow range of values, the minimum of which is prescribed by the European Waste Directive 2000/76/CE, whereas the maximum value must be such as to ensure the preservation of the materials and the energy efficiency of the plant. A high degree of accuracy in measuring and controlling the aforementioned temperature is therefore required. In almost the totality of WTE plants this measurement process is carried out by using practical industrial thermometers, such as bare thermocouples and infrared radiation (IR pyrometers, even if affected by different physical contributions which can make the gas temperature measurements incorrect. The objective of this paper is to analyze errors and uncertainties that can arise when using a bare thermocouple or an IR pyrometer in a WTE plant and to provide a method for the in situ calibration of these industrial sensors through the use of suction pyrometers. The paper describes principle of operation, design, and uncertainty contributions of suction pyrometers, it also provides the best estimation of the flue-gas temperature in the post combustion zone of a WTE plant and the estimation of its expanded uncertainty.

  9. Blood loss associated with Ring uncemented total knee replacement: comparison between continuous and intermittent suction drainage.

    Science.gov (United States)

    Wittmann, F W; Ring, P A

    1984-01-01

    In a retrospective comparison of blood loss following uncemented total knee replacement, in which either continuous or intermittent suction drainage was used, measured blood loss was significantly greater with continuous drainage. However, a method of calculating actual blood loss demonstrated no significant difference. With intermittent drainage, more blood remains undetected around the knee joint; this technique should therefore be abandoned in favour of continuous suction drainage. PMID:6747978

  10. Hydrogenation study of suction-cast Ti{sub 40}Zr{sub 40}Ni{sub 20} quasicrystal

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Huogen; Li, Rong; Yin, Chen; Zheng, Shaotao; Zhang, Pengcheng [National Key Laboratory for Surface Physics and Chemistry, P.O. Box 718-35, Mian Yang 621907, Sichuan (China)

    2008-09-15

    Suction casting was predicted to be an usable method for improving the hydriding kinetics of Ti/Zr-based icosahedral quasicrystals (IQCs) in our previous work. To further determine it, a suction-cast Ti{sub 40}Zr{sub 40}Ni{sub 20} IQC alloy was used for hydrogenation studies by Pressure Composition Isotherm (PCI) and Temperature Programmed Desorption (TPD) techniques. The results showed that, this alloy absorbed hydrogen rapidly with obvious hydrogen pressure plateau and some reversibility, however, displayed very limited hydrogen capacity (about 0.7 wt.%) and low equilibrium pressure. After several hydrogenation/dehydrogenation cycles, the IQC structure transformed into two hydride phases, ZrH{sub 2-x} and one unknown, both of which decomposed at above 600 C, suggesting high thermo-stability for them. On the whole, indeed the suction-casting method can increase the hydrogen absorption rate of Ti/Zr-based IQCs, however, the hydrogenation properties of the Ti{sub 40}Zr{sub 40}Ni{sub 20} IQC alloy still need a mighty advancement. (author)

  11. Silent cooling system with a double suction type centrifugal fan with backward blades; Ryosuikomi turbo fan wo mochiita teisoon engine reikyaku system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Funabashi, S. [Hitachi, Ltd., Tokyo (Japan); Nakamura, K. [Hitachi Construction Machinery Co. Ltd., Tokyo (Japan)

    2000-04-25

    We have developed a new cooling system for the engine of construction machinery. This system produces two different air flow routes by a double suction type centrifugal fan with backward blades. We first measured aerodynamic performance and sound level of the double suction type fan, which consists of two single suction type fans of different design, and compared these measurements to those of single suction type fans. Next, we installed the fan in a scale model of the new cooling system. The performance of this double suction type fan was different to that of a single suction type. It is considered that the effect of interaction of the exit flows from the two different fans caused this performance change. The test model installed in an engine compartment showed that this cooling system reduced the area of air inlets and outlets around the engine and did not cause re-circulation of cooling air. (author)

  12. Heat-transfer and pressure distributions for laminar separated flows downstream of rearward-facing steps with and without mass suction

    Science.gov (United States)

    Brown, R. D.; Jakubowski, A. K.

    1974-01-01

    Heat-transfer and pressure distributions were measured for laminar separated flows downstream of rearward-facing steps with and without mass suction. The flow conditions were such that the boundary-layer thickness was comparable to or larger than the step height. For both suction and no-suction cases, an increase in the step height resulted in a sharp decrease in the initial heat-transfer rates behind the step. Downstream, however, the heat transfer gradually recovered back to less than or near attached-flow values. Mass suction from the step base area increased the local heat-transfer rates; however, this effect was relatively weak for the laminar flows considered. Even removal of the entire approaching boundary layer raised the post-step heat-transfer rates only about 10 percent above the flatplate values. Post-step pressure distributions were found to depend on the entrainment conditions at separation. In the case of the solid-faced step, a sharp pressure drop behind the step was followed by a very short plateau and relatively fast recompression. For the slotted-step connected to a large plenum but without suction, the pressure drop at the base was much smaller and the downstream recompression more gradual than that for solid-faced step.

  13. Active technique by suction to control the flow structure over a van model

    Science.gov (United States)

    Harinaldi, Budiarso, Warjito, Kosasih, Engkos A.; Tarakka, Rustan; Simanungkalit, Sabar P.

    2012-06-01

    Today research trend in car aerodynamics are carried out from the point of view of the durable development. Some car companies have the objective to develop control solution that enable to reduce the aerodynamic drag of vehicle. It provides the possibility to modify the flow separation to reduce the development of the swirling structures around the vehicle. In this study, a family van is modeled with a modified form of Ahmed's body by changing the orientation of the flow from its original form (modified/reversed Ahmed Body). This model is equipped with a suction on the rear side to comprehensively examine the pressure field modifications that occur. The investigation combines computational and experimental work. The computational simulation used is k-epsilon flow turbulence model. The reversed Ahmed body used in the investigation has slant angle (φ) 35° at the front part. In the computational work, meshing type is tetra/hybrid element with hex core type and the grid number is more than 1.7 million in order to ensure detail discretization and more accurate calculation results. The boundary condition is upstream velocity of 11.1 m/s. Mean free stream at far upstream region is assumed in a steady state condition and uniform. The suction velocity is set at 1 m/s. Meanwhile in the experimental work a reversed Ahmed model is tested in a controlled wind tunnel experiments. The main measurement is the drag aerodynamic measurement at rear of the body of the model using strain gage. The results show that the application of a suction in the rear part of the van model give the effect of reducing the wake and the vortex is formed. Aerodynamic drag reduction close to 24% for the computational approach and 14.8% for the experimental approach by introducing a suction have been obtained.

  14. Vortical and acoustical mode coupling inside a porous tube with uniform wall suction.

    Science.gov (United States)

    Jankowskia, T A; Majdalani, J

    2005-06-01

    This paper considers the oscillatory motion of gases inside a long porous tube of the closed-open type. In particular, the focus is placed on describing an analytical solution for the internal acoustico-vortical coupling that arises in the presence of appreciable wall suction. This unsteady field is driven by longitudinal oscillatory waves that are triggered by small unavoidable fluctuations in the wall suction speed. Under the assumption of small amplitude oscillations, the time-dependent governing equations are linearized through a regular perturbation of the dependent variables. Further application of the Helmholtz vector decomposition theorem enables us to discriminate between acoustical and vortical equations. After solving the wave equation for the acoustical contribution, the boundary-driven vortical field is considered. The method of matched-asymptotic expansions is then used to obtain a closed-form solution for the unsteady momentum equation developing from flow decomposition. An exact series expansion is also derived and shown to coincide with the numerical solution for the problem. The numerically verified end results suggest that the asymptotic scheme is capable of providing a sufficiently accurate solution. This is due to the error associated with the matched-asymptotic expansion being smaller than the error introduced in the Navier-Stokes linearization. A basis for comparison is established by examining the evolution of the oscillatory field in both space and time. The corresponding boundary-layer behavior is also characterized over a range of oscillation frequencies and wall suction velocities. In general, the current solution is found to exhibit features that are consistent with the laminar theory of periodic flows. By comparison to the Sexl profile in nonporous tubes, the critically damped solution obtained here exhibits a slightly smaller overshoot and depth of penetration. These features may be attributed to the suction effect that tends to

  15. Suction blister lesions and epithelialization monitored by optical coherence tomography

    DEFF Research Database (Denmark)

    Ahlström, M G; Gjerdrum, L M R; Larsen, H F

    2018-01-01

    suction blister was raised on each buttock, and the blister roof was excised. Lesions were covered with moisture-retaining dressing. In Study 1, the lesions were OCT-scanned on day 0 (D0), D2 and D4 and excised for histological examination. In Study 2, the progress of epithelialization and skin barrier...

  16. Closed suction drainage using Lichtenstein technique in preventing wound complications following inguinal hernioplasty: brief report

    Directory of Open Access Journals (Sweden)

    Hamid Reza Hemmati

    2015-03-01

    Results: No adverse event including hematoma, seroma or wound infection occurred in either group with or without closed suction drainage in the first 10 days after surgery. Only one patient carried wound infection during days 10 to 15 following operation who was in the group with closed drainage (P=1.00. Conclusion: In this study, Seroma and hematoma was not observed in patients with and without closed suction drainage. To avoid drains' complications, indiscriminate use of antibiotics, prolonged hospital stay, we do not recommend the use of drains in this type of surgery.

  17. Systematic review and meta-analysis of closed suction drainage versus non-drainage in primary hip arthroplasty.

    LENUS (Irish Health Repository)

    Kelly, Enda G

    2014-03-01

    The routine use of drains in surgery has been dogmatically instituted in some disciplines. Orthopaedic surgery is one such sub-speciality. The use of postoperative closed suction drainage in total hip arthroplasty (THA) has become increasingly controversial with multiple randomised control trials performed to assess the benefit to outcome in THA. The hypothesis of this systematic review is that closed suction drainage does not infer a benefit and increase transfusion requirements of primary total hip arthroplasty patients. A systematic review and meta-analysis was conducted adhering to the PRISMA guidelines. A search of the available literature was performed on PubMed, Cochrane Central Registry of Controlled Trials, MEDLINE (OVID) and EMBASE using a combination of MeSH terms and Boolean operators. All data analysis was performed using the Cochrane Collaboration\\'s Review Manager 5.1. Sixteen studies (n=2705) were included in the analysis. Post-operative closed suction drainage was found to increase total blood loss and blood transfusion requirements (p<0.05). Surgical site infection demonstrated no significant difference between the two groups (p=0.82). No significant difference in haematoma formation between groups (p=0.19) was elicited. The routine use of closed suction drainage systems post primary hip arthroplasty is not supported by this meta-analysis. However, the heterogeneity between studies does limit the accuracy of the meta-analysis.

  18. [Pain assessment of tracheal suctioning on brain injury patients by pain behavioral indicator scale (ESCID)].

    Science.gov (United States)

    López-López, C; Murillo-Pérez, M A; Morales-Sánchez, C; Torrente-Vela, S; Orejana-Martín, M; García-Iglesias, M; Cuenca-Solanas, M; Alted-López, E

    2014-01-01

    To assess pain response on patients with moderate to severe head injury before a common nursing procedure: tracheal suctioning. An observational longitudinal pilot study with consecutive sampling performed from September to December of 2012. Pain was assessed by a pain behavioral indicator scale 5 minutes before, meanwhile and 15 minutes after tracheal suctioning the days 1, 3 and 6 of their intensive care unit (ICU) stay, as well as a non-painful procedure: rubbing with gauze the forearm of the patient. Pseudo-analgesia and hemodynamic variables were also recorded. Descriptive analysis of the variables, inferential statistics with t-student and Anova with SPSS 17.0; statistical tests were considered significant if the critical level observed was less than 5% (P.05) were shown. Data for the painless procedure were significantly different on day 6 (P<.05) CONCLUSION: During tracheal suctioning in patients with head injury in the first 6 days in the ICU, objective mild-moderate pain according to ESCID scale has been detected. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  19. The radontechnical process of the sub-slab suction system in detached, semi-detached and terraced houses; Imupistejaerjestelmaen radontekninen toiminta eri tyyppisissae pien- ja rivitaloissa

    Energy Technology Data Exchange (ETDEWEB)

    Kettunen, A.V.; Rissanen, R.; Viljanen, M. [Helsinki Univ. of Technology, Otaniemi (Finland). Lab. of Structural Engineering and Building Physics; Arvela, H. [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)

    1997-12-31

    The sub-slab suction system is a repair method for decreasing radon transfer from soil to indoor air in houses. The sub-slab suction system changes the flow field with the aim to reduce the radon content under the ground slab or/and changes the flow direction from indoor air to foundation soil. The study is divided into the theoretical and experimental part. The theoretical part concentrates on solving the factors affecting the sub-slab suction system taking into consideration features of old houses. The experimental part uses the results of the theoretical part when the level and the type of the suction point had been chosen. The effect of the sub-slab suction system was tested with pressure difference experiments and the radon content measurements in 26 different, typical Finnish detached, semi-detached and terrace houses.

  20. Suction/inspiration against resistance or standardized Mueller maneuver: a new breathing technique to improve contrast density within the pulmonary artery: a pilot CT study

    Energy Technology Data Exchange (ETDEWEB)

    Gutzeit, Andreas [Paracelsus Medical University Salzburg, Department of Radiology, Salzburg (Austria); Hirslanden Hospital St. Anna, Institute of Radiology and Nuclear Medicine, Clinical Research Unit, Lucerne (Switzerland); Kantonsspital Winterthur, Department of Radiology, Winterthur (Switzerland); Froehlich, Johannes M.; Weymarn, Constantin von; Goyen, Matthias [Hirslanden Hospital St. Anna, Institute of Radiology and Nuclear Medicine, Clinical Research Unit, Lucerne (Switzerland); Waelti, Stephan [Cantonal Hospital St. Gallen, Department of Radiology and Nuclear Medicine, St. Gallen (Switzerland); Roos, Justus E. [Duke University Medical Center, Department of Radiology, Durham, NC (United States); Meissnitzer, Matthias; Hergan, Klaus [Paracelsus Medical University Salzburg, Department of Radiology, Salzburg (Austria); Czell, David [Cantonal Hospital Winterthur, Department of Neurology, Winterthur (Switzerland); Reischauer, Carolin [Paracelsus Medical University Salzburg, Department of Radiology, Salzburg (Austria); Hirslanden Hospital St. Anna, Institute of Radiology and Nuclear Medicine, Clinical Research Unit, Lucerne (Switzerland)

    2015-11-15

    Our aim was to prospectively investigate whether the recently introduced suction/inspiration against resistance breathing method leads to higher computed tomography (CT) contrast density in the pulmonary artery compared to standard breathing. The present study was approved by the Medical Ethics committee and all subjects gave written informed consent. Fifteen patients, each without suspicious lung emboli, were randomly assigned to four different groups with different breathing maneuvers (suction against resistance, Valsalva, inspiration, expiration) during routine CT. Contrast enhancement in the central and peripheral sections of the pulmonary artery were measured and compared with one another. Peripheral enhancement during suction yielded increased mean densities of 138.14 Hounsfield units (HU) (p = 0.001), compared to Valsalva and a mean density of 67.97 HU superior to inspiration (p = 0.075). Finally, suction in comparison to expiration resulted in a mean increase of 30.51 HU (p = 0.42). Central parts of pulmonary arteries presented significantly increased enhancement values (95.74 HU) for suction versus the Valsalva technique (p = 0.020), while all other mean densities were in favour of suction (versus inspiration: p = 0.201; versus expiration: p = 0.790) without reaching significance. Suction/Inspiration against resistance is a promising technique to improve contrast density within pulmonary vessels, especially in the peripheral parts, in comparison to other breathing maneuvers. (orig.)

  1. Air suctioning during colon biopsy forceps removal reduces bacterial air contamination in the endoscopy suite.

    Science.gov (United States)

    Vavricka, S R; Tutuian, R; Imhof, A; Wildi, S; Gubler, C; Fruehauf, H; Ruef, C; Schoepfer, A M; Fried, M

    2010-09-01

    Bacterial contamination of endoscopy suites is of concern; however studies evaluating bacterial aerosols are lacking. We aimed to determine the effectiveness of air suctioning during removal of biopsy forceps in reducing bacterial air contamination. This was a prospective single-blinded trial involving 50 patients who were undergoing elective nontherapeutic colonoscopy. During colonoscopy, endoscopists removed the biopsy forceps first without and then with suctioning following contact with the sigmoid mucosa. A total of 50 L of air was collected continuously for 30 seconds at 30-cm distance from the biopsy channel valve of the colonoscope, with time starting at forceps removal. Airborne bacteria were collected by an impactor air sampler (MAS-100). Standard Petri dishes with CNA blood agar were used to culture Gram-positive bacteria. Main outcome measure was the bacterial load in endoscopy room air. At the beginning and end of the daily colonoscopy program, the median (and interquartile [IQR] range) bioaerosol burden was 4 colony forming units (CFU)/m (3) (IQR 3 - 6) and 16 CFU/m (3) (IQR 13 - 18), respectively. Air suctioning during removal of the biopsy forceps reduced the bioaerosol burden from a median of 14 CFU/m (3) (IQR 11 - 29) to a median of 7 CFU/m (3) (IQR 4 - 16) ( P = 0.0001). Predominantly enterococci were identified on the agar plates. The bacterial aerosol burden during handling of biopsy forceps can be reduced by applying air suction while removing the forceps. This simple method may reduce transmission of infectious agents during gastrointestinal endoscopies. Copyright Georg Thieme Verlag KG Stuttgart . New York.

  2. Laboratory determined suction potential of Topopah Spring tuff at high temperatures

    International Nuclear Information System (INIS)

    Daily, W.; Lin, Wunan.

    1991-01-01

    The purpose of this work is to experimentally determine the capillary suction potential of Topopah Spring tuff from Yucca Mountain, Nye County, Nevada. This data can be used to help characterize the unsaturated hydraulic properties of the densely welded tuff at this site. 7 refs., 4 figs., 1 tab

  3. Instruction Workbook for Tracheostomy Suctioning and Misting in a School Setting.

    Science.gov (United States)

    Wolf, Karen McKinney; Roach, Antionette Andolfatto

    The handbook presents California guidelines for training school personnel to provide skilled nursing procedures such as tracheostomy suctioning and misting for students with special health needs. The workbook begins with an overview of the anatomy and function of the respiratory system, specifically breathing mechanics. Part 2 considers the…

  4. A wet-tolerant adhesive patch inspired by protuberances in suction cups of octopi

    Science.gov (United States)

    Baik, Sangyul; Kim, Da Wan; Park, Youngjin; Lee, Tae-Jin; Ho Bhang, Suk; Pang, Changhyun

    2017-06-01

    Adhesion strategies that rely on mechanical interlocking or molecular attractions between surfaces can suffer when coming into contact with liquids. Thus far, artificial wet and dry adhesives have included hierarchical mushroom-shaped or porous structures that allow suction or capillarity, supramolecular structures comprising nanoparticles, and chemistry-based attractants that use various protein polyelectrolytes. However, it is challenging to develop adhesives that are simple to make and also perform well—and repeatedly—under both wet and dry conditions, while avoiding non-chemical contamination on the adhered surfaces. Here we present an artificial, biologically inspired, reversible wet/dry adhesion system that is based on the dome-like protuberances found in the suction cups of octopi. To mimic the architecture of these protuberances, we use a simple, solution-based, air-trap technique that involves fabricating a patterned structure as a polymeric master, and using it to produce a reversed architecture, without any sophisticated chemical syntheses or surface modifications. The micrometre-scale domes in our artificial adhesive enhance the suction stress. This octopus-inspired system exhibits strong, reversible, highly repeatable adhesion to silicon wafers, glass, and rough skin surfaces under various conditions (dry, moist, under water and under oil). To demonstrate a potential application, we also used our adhesive to transport a large silicon wafer in air and under water without any resulting surface contamination.

  5. Abdominal drainage following cholecystectomy: high, low, or no suction?

    OpenAIRE

    McCormack, T. T.; Abel, P. D.; Collins, C. D.

    1983-01-01

    A prospective trial to assess the effect of suction in an abdominal drain following cholecystectomy was carried out. Three types of closed drainage system were compared: a simple tube drain, a low negative pressure drain, and a high negative pressure drain: 120 consecutive patients undergoing cholecystectomy were randomly allocated to one of the three drainage groups. There was no significant difference in postoperative pyrexia, wound infection, chest infection, or hospital stay. This study f...

  6. Fabricating Zr-Based Bulk Metallic Glass Microcomponent by Suction Casting Using Silicon Micromold

    Directory of Open Access Journals (Sweden)

    Zhijing Zhu

    2014-08-01

    Full Text Available A suction casting process for fabricating Zr55Cu30Al10Ni5 bulk metallic glass microcomponent using silicon micromold has been studied. A complicated BMG microgear with 50 μm in module has been cast successfully. Observed by scanning electron microscopy and laser scanning confocal microscopy, we find that the cast microgear duplicates the silicon micromold including the microstructure on the surface. The amorphous state of the microgear is confirmed by transmission election microscopy. The nanoindentation hardness and elasticity modulus of the microgear reach 6.5 GPa and 94.5 GPa. The simulation and experimental results prove that the suction casting process with the silicon micromold is a promising one-step method to fabricate bulk metallic glass microcomponents with high performance for applications in microelectromechanical system.

  7. Magnetohydrodynamics effect on three-dimensional viscous incompressible flow between two horizontal parallel porous plates and heat transfer with periodic injection/suction

    Directory of Open Access Journals (Sweden)

    R. C. Chaudhary

    2004-11-01

    Full Text Available We investigate the hydromagnetic effect on viscous incompressible flow between two horizontal parallel porous flat plates with transverse sinusoidal injection of the fluid at the stationary plate and its corresponding removal by periodic suction through the plate in uniform motion. The flow becomes three dimensional due to this injection/suction velocity. Approximate solutions are obtained for the flow field, the pressure, the skin-friction, the temperature field, and the rate of heat transfer. The dependence of solution on M (Hartmann number and λ (injection/suction is investigated by the graphs and tables.

  8. Suction removal of sediment from between armour blocks. Part 2. Waves

    DEFF Research Database (Denmark)

    Dixen, Figen Hatipoglu; Sumer, B. Mutlu; Fredsøe, Jørgen

    2008-01-01

    When a stone/armor layer on a sand bed is exposed to flow, the sand underneath will be agitated by the flow turbulence. When the flow velocity reaches a critical value, the sand will be sucked (winnowed out) from between the armor blocks. In a previous investigation, we studied suction removal of...

  9. The impact of soil suction variation on earthquake intensity indices

    Directory of Open Access Journals (Sweden)

    Biglari Mahnoosh

    2016-01-01

    Full Text Available Soil properties can completely change the ground motion characteristics as they travel from the bedrock to the surface because, soil as a low-pass filter, may amplify or deamplify seismic motions in some frequencies on the wave travelling path. Recent studies about the advanced unsaturated soil mechanics clearly shows that dynamic properties of soils, including small-strain shear modulus (Gmax, shear modulus reduction (G/Gmax, and damping ratio (D curves are affected by changes in the soil suction level. The current study present nonlinear time-dependent analysis of three different unsaturated soils available in the literature with different ranges of nonlinear behaviour that earlier have been studied on unsaturated dynamic models. Since, the earthquake intensity parameters can be used to describe the damage potential of an earthquake, the focus of this paper is to evaluate the impact of the suction variation on the engineering ground motion parameters, including peak values of strong motion, Vmax/Amax, root-mean-square acceleration, Arias intensity, characteristic intensity, cumulative absolute velocity, acceleration spectrum intensity, effective design acceleration, A95 parameter and predominant period separately under the near-field and the far-field seismicity categories.

  10. INCOMPRESSIBLE LAMINAR BOUNDARY LAYER CONTROL BY BLOWING AND SUCTION

    OpenAIRE

    AZZEDINE NAHOUI; LAKHDAR BAHI

    2013-01-01

    A two-dimensional incompressible laminar boundary layer and its control using blowing and suction over a flat plate and around the NACA 0012 and 661012 profiles, is studied numerically. The study is based on the Prandtl boundary layer model using the finite differences method and the Crank-Nicolson scheme. The velocity distribution, the boundary layer thickness and the friction coefficient, are determined and presented with and without control. The application of the control technique, has de...

  11. A Constitutive Model for Unsaturated soils based on a Compressibility Framework dependent on Suction and Degree of Saturation

    OpenAIRE

    Sitarenios Panagiotis; Kavvadas Michael

    2016-01-01

    The Modified Cam Clay model is extended to account for the behaviour of unsaturated soils using Bishop’s stress. To describe the Loading – Collapse behaviour, the model incorporates a compressibility framework with suction and degree of saturation dependent compression lines. For simplicity, the present paper describes the model in the triaxial stress space with characteristic simulations of constant suction compression and triaxial tests, as well as wetting tests. The model reproduces an evo...

  12. Investigation on creep behavior of geo-materials with suction control technique

    Directory of Open Access Journals (Sweden)

    Nishimura Tomoyoshi

    2016-01-01

    Full Text Available The compacted bentonite which has typical couple problem associated to thermal - hydration - mechanical – chemical (THMC consist of one component of engineered barrier. Recently, the couple THMC formulation modelling suggested by some researchers can be predicted basically phenomena for engineered barrier that approach to correct evaluate satisfied facilities. The compacted bentonite is essentially unsaturated condition, some behaviors for bentonite has similar or close with generally expansive unsaturated soils. Therefore, hydrations have given significant influence on deformation of compacted bentonite such as swelling. There are many researches for swelling behavior of compacted bentonite within soaking. Extended theoretical or experimental investigations for unsaturated soil mechanics are possible to describe the strength-deformation behavior of compacted bentonite with suction controlling principle. A new method of determining the failure phase such as great axis deformation and destructions like strip of surface in the laboratory is described and the creep behavior of compacted bentonite is considered under maintain of high relative humidity environment. The creep deformation measured using improved cyclic relative humidity control apparatus in terms of specific suction control technique.

  13. Comparison of numerical formulations for the modeling of tensile loaded suction buckets

    DEFF Research Database (Denmark)

    Sørensen, Emil Smed; Clausen, Johan Christian; Damkilde, Lars

    2017-01-01

    The tensile resistance of a suction bucket is investigated using three different numerical formulations. The first formulation utilizes the three-field u-p-U formulation accounting for solid and fluid displacements, u and U, as well as the pore-fluid pressure, p. The two other formulations compri...

  14. Long term effects of cyclic loading on suction caisson foundations in sand

    NARCIS (Netherlands)

    Lupea, C.; Thijssen, R.; Van Tol, A.F.

    2014-01-01

    Offshore wind turbine projects have been characterised by an increase in costs, sizes and distances from shore, EWEA 2012 This created a need of investigating the adequacy of alternative and more fìnancially attractive foundation types such as suction caissons. Within a multi-footing configuration,

  15. Kinematics of suction feeding in the seahorse Hippocampus reidi.

    Science.gov (United States)

    Roos, Gert; Van Wassenbergh, Sam; Herrel, Anthony; Aerts, Peter

    2009-11-01

    Fish typically use a rostro-caudal wave of head expansion to generate suction, which is assumed to cause a uni-directional, anterior-to-posterior flow of water in the expanding head. However, compared with typical fish, syngnathid fishes have a remarkably different morphology (elongated snout, small hyoid, immobile pectoral girdle) and feeding strategy (pivot feeding: bringing the small mouth rapidly close to the prey by neurocranial dorsorotation). As a result, it is unclear how suction is generated in Syngnathidae. In this study, lateral and ventral expansions of the head were quantified in Hippocampus reidi and linked to the kinematics of the mouth, hyoid and neurocranium. In addition, the flow velocities inside the bucco-pharyngeal cavity and in front of the mouth were calculated. Our data suggest that the volume changes caused by lateral expansion are dominant over ventral expansion. Maximum gape, neurocranium rotation and hyoid depression are all reached before actual volume increase and before visible prey movement. This implies that, unlike previously studied teleosts, hyoid rotation does not contribute to ventral expansion by lowering the floor of the mouth during prey capture in H. reidi. The lateral volume changes show a rostro-caudal expansion, but the maximal flow velocity is not near the mouth aperture (as has been demonstrated for example in catfish) but at the narrow region of the buccal cavity, dorsal to the hyoid.

  16. Successful Laparoscopically Assisted Transcervical Suction Evacuation of Interstitial Pregnancy following Failed Methotrexate Injection in a Community Hospital Setting

    Directory of Open Access Journals (Sweden)

    Rani B. Fritz

    2014-01-01

    Full Text Available We report on a case of a patient with an early diagnosed cornual ectopic pregnancy following failed methotrexate treatment. The patient was subsequently taken to the operating room for a laparoscopic guided transcervical suction curettage of the cornual ectopic. The surgery was successful and the patient was followed up until her urine pregnancy test was negative. We conclude that in properly selected patients, cornual ectopic pregnancy may be treated with transcervical suction curettage.

  17. Differential Effects of Endotracheal Suctioning on Gas Exchanges in Patients with Acute Respiratory Failure under Pressure-Controlled and Volume-Controlled Ventilation

    Directory of Open Access Journals (Sweden)

    Xiao-Wei Liu

    2015-01-01

    Full Text Available This study was conducted to evaluate the effects of open endotracheal suctioning on gas exchange and respiratory mechanics in ARF patients under the modes of PCV or VCV. Ninety-six ARF patients were treated with open endotracheal suctioning and their variations in respiratory mechanics and gas exchange after the suctions were compared. Under PCV mode, compared with the initial level of tidal volume (VT, ARF patients showed 30.0% and 27.8% decrease at 1 min and 10 min, respectively. Furthermore, the initial respiratory system compliance (Crs decreased by 29.6% and 28.5% at 1 min and 10 min, respectively. Under VCV mode, compared with the initial level, 38.6% and 37.5% increase in peak airway pressure (PAP were found at 1 min and 10 min, respectively. Under PCV mode, the initial PaO2 increased by 6.4% and 10.2 % at 3 min and 10 min, respectively, while 18.9% and 30.6% increase of the initial PaO2 were observed under VCV mode. Summarily, endotracheal suctioning may impair gas exchange and decrease lung compliance in ARF patients receiving mechanical ventilation under both PCV and VCV modes, but endotracheal suctioning effects on gas exchange were more severe and longer-lasting under PCV mode than VCV.

  18. Aerosol distribution during open suctioning and long-term surveillance of air quality in a respiratory care center within a medical center.

    Science.gov (United States)

    Chung, Fen-Fang; Lin, Hui-Ling; Liu, Hsueh-Erh; Lien, Angela Shin-Yu; Hsiao, Hsiu-Feng; Chou, Lan-Ti; Wan, Gwo-Hwa

    2015-01-01

    The investigation of hospital air quality has been conducted in wards, ICUs, operating theaters, and public areas. Few studies have assessed air quality in respiratory care centers (RCCs), especially in mechanically ventilated patients with open suctioning. The RCC air quality indices (temperature, relative humidity, levels of CO2, total volatile organic compounds, particulate matter [PM], bacteria, and fungi) were monitored over 1 y. The air around the patient's head was sampled during open suctioning to examine the probability of bioaerosol exposure affecting health-care workers. This investigation found that the levels of indoor air pollutants (CO2, PM, bacteria, and fungi) were below the indoor air quality standard set by the Taiwan Environmental Protection Agency. Meanwhile, the levels of total volatile organic compounds sometimes exceeded the indoor air quality standard, particularly in August. The identified bacterial genera included Micrococcus species, Corynebacterium species, and Staphylococcus species, and the predominant fungal genera included yeast, Aspergillus species, Scopulariopsis species, and Trichoderma species. Additionally, airborne PM2.5, PM1, and bacteria were clearly raised during open suctioning in mechanically ventilated patients. This phenomenon demonstrated that open suctioning may increase the bacterial exposure risk of health-care workers. RCC air quality deserves long-term monitoring and evaluation. Health-care workers must implement self-protection strategies during open suctioning to ensure their occupational health and safety in health-care settings. Copyright © 2015 by Daedalus Enterprises.

  19. Development in corrosion resistance by microstructural refinement in Zr-16 SS 304 alloy using suction casting technique

    Energy Technology Data Exchange (ETDEWEB)

    Das, N., E-mail: nirupamd@barc.gov.in; Sengupta, P.; Abraham, G.; Arya, A.; Kain, V.; Dey, G.K.

    2016-08-15

    Highlights: • Grain refinement was made in Zr–16 wt.% SS alloy while prepared by suction casting process. • Distribution of Laves phase, e.g., Zr{sub 2}(Fe, Cr) was raised in suction cast (SC) Zr–16 wt.% SS. • Corrosion resistance was improved in SC alloy compared to that of arc-melt-cast alloy. • Grain refinement in SC alloy assisted for an increase in its corrosion resistance. - Abstract: Zirconium (Zr)-stainless steel (SS) hybrid alloys are being considered as baseline alloys for developing metallic-waste-form (MWF) with the motivation of disposing of Zr and SS base nuclear metallic wastes. Zr–16 wt.% SS, a MWF alloy optimized from previous studies, exhibit significant grain refinement and changes in phase assemblages (soft phase: Zr{sub 2}(Fe, Cr)/α-Zr vs. hard phase: Zr{sub 3}(Fe, Ni)) when prepared by suction casting (SC) technique in comparison to arc-cast-melt (AMC) route. Variation in Cr-distribution among different phases are found to be low in suction cast alloy, which along with grain refinement restricted Cr-depletion at the Zr{sub 2}(Fe, Cr)/Zr interfaces, prone to localized attack. Hence, SC alloy, compared to AMC alloy, showed lower current density, higher potential at the breakdown of passivity and higher corrosion potential during polarization experiments (carried out under possible geological repository environments, viz., pH 8, 5 and 1) indicating its superior corrosion resistance.

  20. On the influence of buoyancy and suction/injection In Heat and Mass ...

    African Journals Online (AJOL)

    In this paper, we examined the influence of buoyancy and suction/injection in the problem of unsteady convection with chemical reaction and radiative heat transfer past a flat porous plate moving through a binary mixture in an optically thin environment is presented. The dimensionless governing equations for this ...

  1. Review of pump suction reducer selection: Eccentric or concentric reducers

    OpenAIRE

    Mahaffey, R M; van Vuuren, S J

    2014-01-01

    Eccentric reducers are traditionally recommended for the pump suction reducer fitting to allow for transportation of air through the fitting to the pump. The ability of a concentric reducer to provide an improved approach flow to the pump while still allowing air to be transported through the fitting is investigated. Computational fluid dynamics (CFD) were utilised to analyse six concentric and six eccentric reducer geometries at four different inlet velocities to determine the flow velocity ...

  2. Boundary layer on a flat plate with suction; Couche limite sur paroi plane poreuse avec aspiration

    Energy Technology Data Exchange (ETDEWEB)

    Favre, A; Dumas, R; Verollet, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Institut de Mecanique Statistique de la Turbulence, Faculte des Sciences de Marseille, 13 (France)

    1961-07-01

    This research done in wind tunnel concerns the turbulent boundary layer of a porous flat plate with suction. The porous wall is 1 m long and begins 1 m downstream of the leading edge. The Reynolds number based on the boundary layer thickness is of the order of 16.300. The suction rate defined as the ratio of the velocity perpendicular to the wall to the external flow velocity ranges from 0 to 2 per cent. The pressure gradient can be controlled. The mean velocity profiles have been determined for various positions and suction rates by means of total pressure probes together with the intensities of the turbulent velocity fluctuations components, energy spectra and correlations by means of hot wire anemometers, spectral analyser and correlator. The stream lines, the values of the viscous and turbulent shear stresses, of the local wall friction, of the turbulent energy production term, with some information on the dissipation of the energy have been derived from these measurements. For these data the integral of equation of continuity in boundary layer have been drawn. The suction effects on the boundary layer are important. The suction thoroughly alters the mean velocity profiles by increasing the viscous shear stresses near the wall and decreasing them far from the wall, it diminishes the longitudinal and transversal turbulence intensities, the turbulent shear stresses, and the production of energy of turbulence. These effects are much stressed in the inner part of the boundary layer. On the other hand the energy spectra show that the turbulence scale is little modified, the boundary layer thickness being not much diminished by the suction. The suction effects can be appreciated by comparing twice the suction rate to the wall friction coefficient (assumed airtight), quite noticeable as soon as the rate is about unity, they become very important when it reaches ten. (author) [French] Ces recherches, effectuees en soufflerie, concernent la couche limite turbulente d

  3. Saline instillation before tracheal suctioning decreases the incidence of ventilator-associated pneumonia.

    Science.gov (United States)

    Caruso, Pedro; Denari, Silvia; Ruiz, Soraia A L; Demarzo, Sergio E; Deheinzelin, Daniel

    2009-01-01

    To compare the incidence of ventilator-associated pneumonia (VAP) with or without isotonic saline instillation before tracheal suctioning. As a secondary objective, we compared the incidence of endotracheal tube occlusion and atelectasis. Randomized clinical trial. The study was conducted in a medical surgical intensive care unit of an oncologic hospital. We selected consecutive patients needing mechanical ventilation for >72 hrs. Patients were allocated into two groups: a saline group that received instillation of 8 mL of saline before tracheal suctioning and a control group which did not. VAP was diagnosed based on clinical suspicion and confirmed by bronchoalveolar lavage quantitative culture. The incidence of atelectasis on daily chest radiography and endotracheal tube occlusions were recorded. The sample size was calculated to a power of 80% and a type I error probability of 5%. One hundred thirty patients were assigned to the saline group and 132 to the control group. The baseline demographic variables were similar between groups. The rate of clinically suspected VAP was similar in both groups. The incidence of microbiological proven VAP was significantly lower in the saline group (23.5% x 10.8%; p = 0.008) (incidence density/1.000 days of ventilation 21.22 x 9.62; p < 0.01). Using the Kaplan-Meier curve analysis, the proportion of patients remaining without VAP was higher in the saline group (p = 0.02, log-rank test). The relative risk reduction of VAP in the saline instillation group was 54% (95% confidence interval, 18%-74%) and the number needed to treat was eight (95% confidence interval, 5-27). The incidence of atelectases and endotracheal tube occlusion were similar between groups. Instillation of isotonic saline before tracheal suctioning decreases the incidence of microbiological proven VAP.

  4. Boundary layer development on turbine airfoil suction surfaces

    Science.gov (United States)

    Sharma, O. P.; Wells, R. A.; Schlinker, R. H.; Bailey, D. A.

    1981-01-01

    The results of a study supported by NASA under the Energy Efficient Engine Program, conducted to investigate the development of boundary layers under the influence of velocity distributions that simulate the suction sides of two state-of-the-art turbine airfoils, are presented. One velocity distribution represented a forward loaded airfoil ('squared-off' design), while the other represented an aft loaded airfoil ('aft loaded' design). These velocity distributions were simulated in a low-speed, high-aspect-ratio wind tunnel specifically designed for boundary layer investigations. It is intended that the detailed data presented in this paper be used to develop improved turbulence model suitable for application to turbine airfoil design.

  5. Measuring lip force by oral screens Part 2: The importance of screen design, instruction and suction.

    Science.gov (United States)

    Wertsén, Madeleine; Stenberg, Manne

    2017-10-01

    The aim of this study was to find a reliable method for measuring lip force and to find the most important factors that influence the measurements in terms of magnitude and variability. The hypothesis tested was that suction is involved and thus the instruction and the design of the oral screen are of importance when measuring lip force. This is a methodological study in a healthy population. This study was conducted in a general community. The designs of the screens were soft and hard prefabricated screens and 2 semi-individually made with a tube allowing air to pass. The screens and the instructions squeeze or suck were tested on 29 healthy adults, one at a time and on 4 occasions. The test order of the screens was randomized. Data were collected during 4 consecutive days, and the procedure was repeated after 1 month. The participants were 29 healthy adult volunteers. The instruction was an important mean to distinguish between squeezing and sucking. The design of the screen affected the lip force so that it increases in relation to the projected area of the screen. A screen design with a tube allowing air to pass made it possible to avoid suction when squeezing. By measuring with and without allowing air to pass, it was possible to distinguish between suction related and not suction related lip force. The additional screen pressure when sucking was related to the ability to produce a negative intraoral pressure. In conclusion lip force increases in relation to the projected area of the screen, sucking generally increases the measured lip force and the additional screen pressure when sucking is related to the ability to produce a negative intraoral pressure.

  6. MHD Boundary Layer Flow of Dilatant Fluid in a Divergent Channel with Suction or Blowing

    International Nuclear Information System (INIS)

    Bhattacharyya, Krishnendu; Layek, G. C.

    2011-01-01

    An analysis is carried out to study a steady magnetohydrodynamic (MHD) boundary layer flow of an electrically conducting incompressible power-law non-Newtonian fluid through a divergent channel. The channel walls are porous and subjected to either suction or blowing of equal magnitude of the same kind of fluid on both walls. The fluid is permeated by a magnetic field produced by electric current along the line of intersection of the channel walls. The governing partial differential equation is transformed into a self-similar nonlinear ordinary differential equation using similarity transformations. The possibility of boundary layer flow in a divergent channel is analyzed with the power-law fluid model. The analysis reveals that the boundary layer flow (without separation) is possible for the case of the dilatant fluid model subjected to suitable suction velocity applied through its porous walls, even in the absence of a magnetic field. Further, it is found that the boundary layer flow is possible even in the presence of blowing for a suitable value of the magnetic parameter. It is found that the velocity increases with increasing values of the power-law index for the case of dilatant fluid. The effects of suction/blowing and magnetic field on the velocity are shown graphically and discussed physically. (fundamental areas of phenomenology(including applications))

  7. Reduction of the suction pressure of a liquid ring vacuum pump with a supersonic gas ejector

    Directory of Open Access Journals (Sweden)

    Olšiak Róbert

    2018-01-01

    Full Text Available A supersonic gas ejector in conjunction with a liquid ring vacuum pump is used for creating and maintaining vacuum in a chamber for technological purposes. In this paper the authors submit an overview about the problematics of suction pressure reduction with a supersonic gas ejector used as a pre-stage of a liquid ring vacuum pump. This system has also the function of a cavitation protection due to the higher pressure present at the suction throat of the vacuum pump. A part of this paper is devoted to the governing equations used at the definition of the flow through an ejector. The experimental studies are then carried out in or own laboratory for verification purposes.

  8. Effect of inflow discharges on the development of matric suction and volumetric water content for dike during overtopping tests

    Science.gov (United States)

    Hassan, Marwan A.; Ismail, Mohd A. M.

    2017-10-01

    The point of this review is to depict the impact of various inflow discharge rate releases on the instruments of matric suction and volumetric water content during an experimental test of spatial overtopping failure at school of civil engineering in universiti Sains of Malaysia. A dry sand dike was conducted inside small flume channel with twelve sensors of tensiometer and Time-Domain Reflectometer (TDR). Instruments are installed in the soil at different locations in downstream and upstream slopes of the dike for measuring the response of matric suction and volumetric water content, respectively. Two values of inflow discharge rates of 30 and 40 L/min are utilized as a part of these experiments to simulate the effectiveness of water reservoirs in erosion mechanism. The outcomes demonstrate that the matric suction and volumetric water content are decreased and increased, respectively for both inflow discharges. The higher inflow discharges accelerate the saturation of dike soil and the erosion process faster than that for the lower inflow discharges.

  9. Treatment of herniated lumbar disc by percutaneous laser disc decompression combined with synchronous suction technique through syringe

    Institute of Scientific and Technical Information of China (English)

    Dhir B. Gurung; Gaojian Tao; Hongyi Lin; Yanning Qian; Jian Lin

    2007-01-01

    Objective: To compare the outcomes of percutaneous laser disc decompression (PLDD) and PLDD with synchronous suction through syringe in the patients with herniated lumbar disc (HLD). Methods: Forty-two patients with HLD on MRI and those who did not respond to conservative treatment for 6 weeks were randomly divided into group A and group B. In group A, the patients were treated with PLDD and those in group B with PLDD and synchronous suction through syringe. GaAIAS diode laser at 810 nm was used for the ablation in both groups. The treatment effect was evaluated by modified MacNab's criteria on the 7th, 30th and 90th day. Results: Evaluated by modified MacNab's criteria, the percentages of the excellent and good cases in total patients treated for group B and A were 80.95% and 57.14% on the 7th follow-up day, 85.71% and 66.67% on the 30th follow-up day, and 95.24% and 71.43% on the 90th follow-up day, respectively. Conclusion: Synchronous suction technique through syringe during PLDD improves the overall outcome in the treatment of herniated lumbar disc.

  10. Analysis Of Primary Coolant Suction Side Pressure In The Delay Chamber Of The RSG-GAS

    International Nuclear Information System (INIS)

    Dibyo, Sukmanto

    2000-01-01

    Delay chamber is a tank to delay flow that located in the primary cooling suction side of RSG-GAS. A void occurred when operation reactor caused by too high the delta P at inlet suction pump. The condition may be avoided by using one line mode of the cooling flow. The analysis show that void volume in the delay chamber is occurred because the coolant negative pressure lowers the saturation pressure should be avoided though decreasing the delta P until about 0.1 bar at about 45 exp 0 C. Solution suggested are to use bypass flow from the spent fuel to the delay chamber. Coolant temperature can be also decreased by decreasing the power level of the reactor as well as improving the heat exchanger and cooling tower performances

  11. Bacteremia during adenoidectomy: a comparison of suction diathermy adenoid ablation and adenoid curettage.

    LENUS (Irish Health Repository)

    Casserly, Paula

    2010-08-01

    Transient bacteremia is induced by adenoidectomy when the integrity of the nasopharyngeal membrane is broken. The aim of this study was to determine the incidence of bacteremia in patients undergoing adenoidectomy, to identify the causative organisms, and to compare the incidences of bacteremia between the two techniques suction diathermy and curettage.

  12. Suppression of secondary flows in a double suction centrifugal pump with different loading distributions

    International Nuclear Information System (INIS)

    Leng, H F; Wang, F J; Zhang, Z C; Yao, Z F; Zhou, P J

    2013-01-01

    Secondary flow is one of the main reasons for low efficiency in double suction centrifugal pump. In a 3-D inverse design method, the pump blade could be designed by a specified loading distribution to control the flow field in pump. In order to study the influence of loading distribution on secondary flow of a double suction centrifugal pump, the external characteristics and the internal flow field of the pump with three kinds of loading distributions are analysed by using CFD approach. According to the simulation results, it is found that the form of fore-loading distribution at shroud and aft-loading distribution at hub could improve the optimal efficiency and broaden the high efficiency area of the pump. Furthermore, the secondary flow in impeller exit region and volute could be significantly suppressed if the slope of loading distribution curve of shroud is set to be −0.7

  13. Conceptual Design of Portable Filtered Air Suction Systems For Prevention of Released Radioactive Gas under Severe Accidents of NPP

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Beom W.; Choi, Su Y.; Yim, Man S.; Rim, Chun T. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-05-15

    It becomes evident that severe accidents may occur by unexpected disasters such as tsunami, heavy flood, or terror. Once radioactive material is released from NPP through severe accidents, there are no ways to prevent the released radioactive gas spreading in the air. As a remedy for this problem, the idea on the portable filtered air suction system (PoFASS) for the prevention of released radioactive gas under severe accidents was proposed. In this paper, the conceptual design of a PoFASS focusing on the number of robot fingers and robot arm rods are proposed. In order to design a flexible robot suction nozzle, mathematical models for the gaps which represent the lifted heights of extensible covers for given convex shapes of pipes and for the covered areas are developed. In addition, the system requirements for the design of the robot arms of PoFASS are proposed, which determine the accessible range of leakage points of released radioactive gas. In this paper, the conceptual designs of the flexible robot suction nozzle and robot arm have been conducted. As a result, the minimum number of robot fingers and robot arm rods are defined to be four and three, respectively. For further works, extensible cover designs on the flexible robot suction nozzle and the application of the PoFASS to the inside of NPP should be studied because the radioactive gas may be released from connection pipes between the containment building and auxiliary buildings.

  14. Cyclosporin A levels in suction-blister fluid of patients with psoriasis treated systemically

    NARCIS (Netherlands)

    Meinardi, M. M.; van Eendenburg, J. P.; Oosting, J.; van Boxtel, C. J.; de Rie, M. A.; Bos, J. D.

    1990-01-01

    Oral cyclosporin A (CyA) is highly effective in the treatment of psoriasis. The long-term use is limited by dose-dependent side-effects, and the local concentration of CyA is a determining factor in treatment. The concentration of CyA in suction-blister fluid (SBF) and in whole blood was assessed

  15. In situ sampling of small volumes of soil solution using modified micro-suction cups

    NARCIS (Netherlands)

    Shen, Jianbo; Hoffland, E.

    2007-01-01

    Two modified designs of micro-pore-water samplers were tested for their capacity to collect unbiased soil solution samples containing zinc and citrate. The samplers had either ceramic or polyethersulfone (PES) suction cups. Laboratory tests of the micro-samplers were conducted using (a) standard

  16. A comparison of the disconnection technique with continuous bronchial suction for lung deflation when using the Arndt endobronchial blocker during video-assisted thoracoscopy: A randomised trial.

    Science.gov (United States)

    El-Tahan, Mohamed R

    2015-06-01

    The use of the Arndt endobronchial blocker has not gained widespread acceptance during video-assisted thoracoscopic surgery (VATS) because of its high cost and longer time to operative lung collapse especially in patients with chronic obstructive pulmonary disease (COPD). The use of a ventilator disconnection technique has been shown to produce a comparable degree of lung collapse when used with either a double-lumen tube or an Arndt endobronchial blocker. We hypothesised that the use of bronchial suction through the suction port of the endobronchial blocker would be associated with a comparable time to achieve optimum lung collapse as the disconnection technique. A randomised, double-blind study. Single university hospital. Fifty-eight patients with spontaneous pneumothorax scheduled for elective VATS using the Arndt endobronchial blocker for one-lung ventilation (OLV). Patients were randomly assigned to one of two groups (n = 29 per group) to deflate the operative lung with either disconnection of the endotracheal tube from the ventilator for 60 s prior to inflation of the endobronchial blocker or connection of a suction pressure of -30 cmH2O to the suction port of the endobronchial blocker through the barrel of a 1 ml syringe. The primary outcome was the time to total lung collapse. Secondary outcomes included surgeon rating of lung collapse, overall surgeon satisfaction, need for further fibreoptic bronchial suction manoeuvres and intraoperative hypoxaemia. The bronchial suction technique was associated with a significantly shorter time to total lung collapse than the disconnection method [93 (95% confidence interval, 95% CI 81.3 to 103.7) vs. 197 (95% CI 157.4 to 237) s respectively; P < 0.001]. Both the disconnection and bronchial suction groups had a comparable surgical rating of excellent lung collapse 40 min after the start of OLV (65.5 vs. 79.3%, respectively; P = 0.24), overall surgeon satisfaction [median (interquartile range, IQR) 9 (8 to 10) vs. 9 (8

  17. A retrospective study of the use of active suction wound drains in dogs and cats.

    Science.gov (United States)

    Bristow, P C; Halfacree, Z J; Baines, S J

    2015-05-01

    To report indications for use and complications associated with commonly used closed active suction wound drains in a large number of clinical cases. Retrospective review of medical case records (from 2004 to 2010) for dogs and cats that had a closed active suction drain placed into a wound. Only the four most common drain types were included: Mini Redovac®, Redovac®, Jackson Pratt® and Wound Evac®. Two hundred and fifty-three drains were placed in 33 cats and 195 dogs. Mini Redovac drains were used most frequently in cats (76 · 5%) and Redovac drains in dogs (54 · 3%). The infection rate for clean surgeries in dogs was 15 · 6% (unattainable in cats). Major complications occurred in four dogs; minor complications occurred in 12 drains in cats (35 · 3%), and in 74 drains in dogs (33 · 8%). There was no statistically significant association between the type of drain and complication rate for either species. Although closed active suction drains can be used with low risk of major complications, they lead to a high rate of infection in clean surgeries in dogs. It is recommended that such drains are kept in place for the shortest time possible and that strict asepsis is adhered to both during placement and management. © 2015 British Small Animal Veterinary Association.

  18. Determination of Matric Suction and Saturation Degree for Unsaturated Soils, Comparative Study - Numerical Method versus Analytical Method

    Science.gov (United States)

    Chiorean, Vasile-Florin

    2017-10-01

    Matric suction is a soil parameter which influences the behaviour of unsaturated soils in both terms of shear strength and permeability. It is a necessary aspect to know the variation of matric suction in unsaturated soil zone for solving geotechnical issues like unsaturated soil slopes stability or bearing capacity for unsaturated foundation ground. Mathematical expression of the dependency between soil moisture content and it’s matric suction (soil water characteristic curve) has a powerful character of nonlinearity. This paper presents two methods to determine the variation of matric suction along the depth included between groundwater level and soil level. First method is an analytical approach to emphasize one direction steady state unsaturated infiltration phenomenon that occurs between the groundwater level and the soil level. There were simulated three different situations in terms of border conditions: precipitations (inflow conditions on ground surface), evaporation (outflow conditions on ground surface), and perfect equilibrium (no flow on ground surface). Numerical method is finite element method used for steady state, two-dimensional, unsaturated infiltration calculus. Regarding boundary conditions there were simulated identical situations as in analytical approach. For both methods, was adopted the equation proposed by van Genuchten-Mualen (1980) for mathematical expression of soil water characteristic curve. Also for the unsaturated soil permeability prediction model was adopted the equation proposed by van Genuchten-Mualen. The fitting parameters of these models were adopted according to RETC 6.02 software in function of soil type. The analyses were performed in both methods for three major soil types: clay, silt and sand. For each soil type were concluded analyses for three situations in terms of border conditions applied on soil surface: inflow, outflow, and no flow. The obtained results are presented in order to highlight the differences

  19. Set-up and Test Procedure for Suction Installation and Uninstallation of Bucket Foundation

    DEFF Research Database (Denmark)

    Koteras, Aleksandra Katarzyna

    This technical report describes the set-up and the test procedures for installation and uninstallation of medium-scale model of bucket foundation that can be performed in the geotechnical part of laboratory in Aalborg University. The installation of bucket foundation can be tested with the use of......) and loading frame used for those tests have been already used for axially static and cyclic loading of piles (Thomassen, 2015a) and for axially static and cyclic loading of bucket foundation (Vaitkunaite et al., 2015).......This technical report describes the set-up and the test procedures for installation and uninstallation of medium-scale model of bucket foundation that can be performed in the geotechnical part of laboratory in Aalborg University. The installation of bucket foundation can be tested with the use...... of suction under the bucket lid or by applying additional force through the hydraulic piston, forcing the bucket to penetrate into the soil. Tests for uninstallation are performed also with the use of water pressure, as a reverse process to the suction installation. Both installation and uninstallation tests...

  20. 75 FR 70112 - Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered Suction...

    Science.gov (United States)

    2010-11-17

    .... FDA-2010-N-0513] Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered... risks. Adverse tissue reaction Material degradation Improper function of suction apparatus (e.g., reflux.... Material degradation Section 8. Stability and Shelf Life. [[Page 70113

  1. Efficacy of intermittent sub-glottic suctioning in prevention of ventilator-associated pneumonia- A preliminary study of 100 patients

    Directory of Open Access Journals (Sweden)

    M N Vijai

    2016-01-01

    Full Text Available Background and Aims: Oropharyngeal colonisation followed by aspiration of contaminated secretions is the major cause for ventilator-associated pneumonia (VAP. Pooled secretions present in the sub-glottic area above inflated endotracheal tube cuff may be aspirated into the lower airways. It was hypothesised that intermittent suctioning of sub-glottic secretions would prevent VAP. Methods: Group I (n = 50 patients were intubated with HiLo Evac™ endotracheal (ET tube with facility for sub-glottic suctioning, and Group II (n = 50 patients were intubated with HiLo Contour™ ET tube without such facility. In the Group I, sub-glottic suctioning was performed every 2 h. Incidence of VAP, mean ventilator days, Intensive Care Unit (ICU stay and mortality were compared. Qualitative variables were reported as percentages and were compared by Chi-square test or unpaired two-tailed, Fisher′s exact test, as appropriate, to analyse the significance of difference between the two groups. Results: The two groups were similar with respect to demographic characteristics. VAP was seen in 6% of patients in Group I and 22% of patients in Group II (P = 0.021. Both early- and late-onset VAPs were significantly reduced in Group I. Both ventilator days (8.0 vs. 6.45; P = 0.001 and ICU stay (8.33 vs. 6.33; P = 0.001 on the day of onset of VAP were significantly more in the Group I. Total ventilator days were significantly less (6.52 vs. 8.32; P = 0.006 with lower incidence of mortality (36% vs. 48%; P = 0.224 in the Group I. Conclusion: Intermittent sub-glottic suctioning reduces the incidence of VAP including late-onset VAP.

  2. Efficacy of intermittent sub-glottic suctioning in prevention of ventilator-associated pneumonia- A preliminary study of 100 patients.

    Science.gov (United States)

    Vijai, M N; Ravi, Parli R; Setlur, Rangaraj; Vardhan, Harsh

    2016-05-01

    Oropharyngeal colonisation followed by aspiration of contaminated secretions is the major cause for ventilator-associated pneumonia (VAP). Pooled secretions present in the sub-glottic area above inflated endotracheal tube cuff may be aspirated into the lower airways. It was hypothesised that intermittent suctioning of sub-glottic secretions would prevent VAP. Group I (n = 50) patients were intubated with HiLo Evac™ endotracheal (ET) tube with facility for sub-glottic suctioning, and Group II (n = 50) patients were intubated with HiLo Contour™ ET tube without such facility. In the Group I, sub-glottic suctioning was performed every 2 h. Incidence of VAP, mean ventilator days, Intensive Care Unit (ICU) stay and mortality were compared. Qualitative variables were reported as percentages and were compared by Chi-square test or unpaired two-tailed, Fisher's exact test, as appropriate, to analyse the significance of difference between the two groups. The two groups were similar with respect to demographic characteristics. VAP was seen in 6% of patients in Group I and 22% of patients in Group II (P = 0.021). Both early- and late-onset VAPs were significantly reduced in Group I. Both ventilator days (8.0 vs. 6.45; P = 0.001) and ICU stay (8.33 vs. 6.33; P = 0.001) on the day of onset of VAP were significantly more in the Group I. Total ventilator days were significantly less (6.52 vs. 8.32; P = 0.006) with lower incidence of mortality (36% vs. 48%; P = 0.224) in the Group I. Intermittent sub-glottic suctioning reduces the incidence of VAP including late-onset VAP.

  3. Stability analysis on the flow and heat transfer of nanofluid past a stretching/shrinking cylinder with suction effect

    Science.gov (United States)

    Bakar, Nor Ashikin Abu; Bachok, Norfifah; Arifin, Norihan Md.; Pop, Ioan

    2018-06-01

    The steady boundary layer flow over a stretching/shrinking cylinder with suction effect is numerically studied. Using a similarity transformations, the governing partial differential equations are transformed into a set of nonlinear differential equations and have been solved numerically using a bvp4c code in Matlab software. The nanofluid model used is taking into account the effects of Brownian motion and thermophoresis. The influences of the governing parameters namely the curvature parameter γ, mass suction parameter S, Brownian motion parameter Nb and thermophoresis parameter Nt on the flow, heat and mass transfers characteristics are presented graphically. The numerical results obtained for the skin friction coefficient, local Nusselt number and local Sherwood number are thoroughly determined and presented graphically for several values of the governing parameters. From our investigation, it is found that the non-unique (dual) solutions exist for a certain range of mass suction parameter. It is observed that as curvature parameter increases, the skin friction coefficient and heat transfer rate decrease, meanwhile the mass transfer rates increase. Moreover, the stability analysis showed that the first solution is linearly stable, while the second solution is linearly unstable.

  4. Simulation of flow structure in the suction pipe of a hydroturbine by integral characteristics

    DEFF Research Database (Denmark)

    Kuibin, P.A.; Okulov, Valery; Pylev, I.M.

    2006-01-01

    Within the framework of a model of a twisted flow of an inviscid incompressible liquid, we solve the problem of determining the frequency and amplitude of oscillations caused by the precession of a helical vortex core in the suction tube of a hydroturbine from the specified integral characteristics...

  5. 77 FR 25717 - Proposed Issuance of a General NPDES Permit for Small Suction Dredging

    Science.gov (United States)

    2012-05-01

    ...) General Permit (IDG-37-0000) to placer mining operations in Idaho for small suction dredges (intake nozzle... ENVIRONMENTAL PROTECTION AGENCY [FRL-9666-1] Proposed Issuance of a General NPDES Permit for Small... certifies ``will not, if promulgated, have a significant economic impact on a substantial number of small...

  6. Controls on shallow landslide initiation: Diverse hydrologic pathways, 3D failure geometries, and unsaturated soil suctions

    Science.gov (United States)

    Reid, Mark; Iverson, Richard; Brien, Dianne; Iverson, Neal; LaHusen, Richard; Logan, Matthew

    2017-04-01

    Shallow landslides and ensuing debris flows are a common hazard worldwide, yet forecasting their initiation at a specific site is challenging. These challenges arise, in part, from diverse near-surface hydrologic pathways under different wetting conditions, 3D failure geometries, and the effects of suction in partially saturated soils. Simplistic hydrologic models typically used for regional hazard assessment disregard these complexities. As an alterative to field studies where the effects of these governing factors can be difficult to isolate, we used the USGS debris-flow flume to conduct controlled, field-scale landslide initiation experiments. Using overhead sprinklers or groundwater injectors on the flume bed, we triggered failures using three different wetting conditions: groundwater inflow from below, prolonged moderate-intensity precipitation, and bursts of high-intensity precipitation. Failures occurred in 6 m3 (0.65-m thick and 2-m wide) prisms of loamy sand on a 31° slope; these field-scale failures enabled realistic incorporation of nonlinear scale-dependent effects such as soil suction. During the experiments, we monitored soil deformation, variably saturated pore pressures, and moisture changes using ˜50 sensors sampling at 20 Hz. From ancillary laboratory tests, we determined shear strength, saturated hydraulic conductivities, and unsaturated moisture retention characteristics. The three different wetting conditions noted above led to different hydrologic pathways and influenced instrumental responses and failure timing. During groundwater injection, pore-water pressures increased from the bed of the flume upwards into the sediment, whereas prolonged moderate infiltration wet the sediment from the ground surface downward. In both cases, pore pressures acting on the impending failure surface slowly rose until abrupt failure. In contrast, a burst of intense sprinkling caused rapid failure without precursory development of widespread positive pore

  7. Short-snouted toothless ichthyosaur from China suggests Late Triassic diversification of suction feeding ichthyosaurs.

    Directory of Open Access Journals (Sweden)

    P Martin Sander

    Full Text Available BACKGROUND: Ichthyosaurs were an important group of Mesozoic marine reptiles and existed from the Early Triassic to the early Late Cretaceous. Despite a great diversity in body shapes and feeding adaptations, all share greatly enlarged eyes, an elongated rostrum with numerous conical teeth, and a streamlined body. METHODOLOGY/PRINCIPAL FINDINGS: Based on new material from China and the restudy of Shastasaurus pacificus, we here reinterpret the classical large-bodied Late Triassic ichthyosaur genus Shastasaurus to differ greatly from the standard ichthyosaurian body plan, indicating much greater morphological diversity and range of feeding adaptations in ichthyosaurs than previously recognized. Phylogenetic analysis indicates a monophyletic clade consisting of the giant Shonisaurus sikanniensis, Guanlingsaurus liangae, and Shastasaurus pacificus to which the genus name Shastasaurus is applied. Shastasaurus liangae comb. nov. is from the Late Triassic (Carnian Xiaowa Formation of Guizhou Province, southwestern China. The species combines a diminutive head with an entirely toothless and greatly reduced snout. The species also has by far the highest vertebral count among ichthyosaurs (86 presacral vertebrae and >110 caudal vertebrae, a count that is also very high for tetrapods in general. A reduced toothless snout and a diminutive head is also apparently present in the giant S. sikanniensis and presumably in S. pacificus. CONCLUSIONS/SIGNIFICANCE: In analogy to many modern odontocetes, Shastasaurus is interpreted as a specialized suction feeder on unshelled cephalopods and fish, suggesting a unique but widespread Late Triassic diversification of toothless, suction-feeding ichthyosaurs. Suction feeding has not been hypothesized for any of the other diverse marine reptiles of the Mesozoic before, but in Shastasaurus may be linked to the Late Triassic minimum in atmospheric oxygen.

  8. Active Flow Control in a Radial Vaned Diffuser for Surge Margin Improvement: A Multislot Suction Strategy

    Directory of Open Access Journals (Sweden)

    Aurélien Marsan

    2017-01-01

    Full Text Available This work is the final step of a research project that aims at evaluating the possibility of delaying the surge of a centrifugal compressor stage using a boundary-layer suction technique. It is based on Reynolds-Averaged Navier-Stokes numerical simulations. Boundary-layer suction is applied within the radial vaned diffuser. Previous work has shown the necessity to take into account the unsteady behavior of the flow when designing the active flow control technique. In this paper, a multislot strategy is designed according to the characteristics of the unsteady pressure field. Its implementation results in a significant increase of the stable operating range predicted by the unsteady RANS numerical model. A hub-corner separation still exists further downstream in the diffuser passage but does not compromise the stability of the compressor stage.

  9. Stall margin improvement of an axial flow fan with end wall injection and suction; Hekimen fukidashi suidashi ni yoru han'yo jikuryu sofuki no shissoku kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Nishioka, K.; Kuroda, H.; Obata, S.; Chimura, O. [National Defense Academy, Kanagawa (Japan)

    1999-06-25

    The experimental studies are conducted to reveal the mechanism of stall margin improvement of an axial flow fan by injection or suction from the end wall. In case of injection, the largest improvement is obtained by the injection at about 0. 14 {approx} 0 .21 times axial chord length downstream from leading edge. The reason for large improvement is that stall vortex, shed intermittent separation vortex and tip leakage vortex are dissipated by this injection, and also that this blowing suppresses the separation of boundary layer. In case of suction, the largest improvement is found for the suction from the end wall near leading edge. The amplitude of periodic static pressure after stall inception becomes smaller in comparison with injection cases. These effects are increased with the increase of suction flow rate, because the discharge of the vortex occurs more easily. On the other hand, the suction from the upstream of leading edge reduces the axial velocity near rotor tip, and then it induces stall. Also we tried to visualize the tip region flow, The suppression mechanism is discussed based on the visualization. The suppression of stall is successfully photographed. (author)

  10. Comparative study of the characteristics of some suction devices for gas sampling applications; Etude comparative des caracteristiques de quelques dispositifs d'aspiration a l'usage des prelevements de gaz

    Energy Technology Data Exchange (ETDEWEB)

    Donguy, R.; Drouet, J.

    1959-06-15

    Gas sampling (used to determine the characteristics of dusts or aerosols contained in a gas) needs a suction device. In order to select the right device and the right conditions of use, the characteristics and performances of various suction devices (helicoidal and centrifugal aspirators, air pumps, volumetric pumps) have been experimentally measured: flow rate, head loss, sampling volume and duration, aerosol and dust concentration, gas density, nature of the gas, suction circuit configuration, etc.

  11. Free Convection from a Semi-Infinite Vertical Plate with Discontinuous Blowing or Suction.

    Science.gov (United States)

    1981-03-01

    SCHIESSR UNCLASSIFIED; EhEllllEllEE EE[E]hEEEIllIEllhlEEIl EEEEEIIIEEEEI EEEIIIIIIIIII EIIIEIIEEEEII EEEIIIIIIIIIIE LVEL NAVAL POSTGRADUATE SCHOOL Monterey...the unsteady free convective flow past a simi-infinite porous plate with constant suction were studied through mathematical analysis by Soundalgekar...boundary-layers and; therefore, will often indicate a preferred method of analytical solution. Although there are several possible mathematical techniques

  12. Application of the time dependent suction to free convection laminar flow in the presence of transverse magnetic field

    International Nuclear Information System (INIS)

    Agrawal, H.L.; Ram, P.C.

    1980-01-01

    The laminar unsteady free convection and heat transfer of an electrically conducting fluid past a porous vertical flat plate in the presence of uniform transverse magnetic field is investigated when the free stream velocity and suction at the plate are oscillatory functions of time, viscous dissipation term and Joul's dissipation term have been neglected at low velocity. Expressions for velocity and temperature distributions have been obtained in the non-dimensional forms and the skin-friction has been calculated. The skin-friction decreases by increasing Hartmann number. The suction is applied to check the growth of the boundary layer. This study is likely to have bearing on the problem of boundary layer control and transpiration cooling. (author)

  13. The use of suction blisters to measure sunscreen protection against UVR-induced DNA damage.

    Science.gov (United States)

    Josse, Gwendal; Douki, Thierry; Le Digabel, Jimmy; Gravier, Eleonore; Questel, Emmanuel

    2018-02-01

    The formation of DNA photoproducts caused by solar UVR exposure needs to be investigated in-vivo and in particular in order to assess sunscreens' level of protection against solar genotoxicity. The study's purposes were: i) to evaluate if the roof of suction blisters is an appropriate sampling method for measuring photoproducts, and ii) to measure in-vivo sunscreen protection against cyclobutane pyrimidine dimers. Skin areas on the interior forearms of eight healthy volunteers were exposed in-vivo to 2 MED of simulated solar radiation (SSR) and to 15 MED on a sunscreen protected area. After irradiation, six suction blisters were induced and the blister roofs were collected. Analysis of SSR-induced CPDs was performed by two independent methods: a chromatography coupled to mass spectroscopy (HPLC-MS/MS) approach and a 3D-imaging of CPD immunostaining by multiphoton microscopy on floating epidermal sheets. HPLC-MS/MS analyses showed that SSR-unexposed skin presented no CPD dimers, whereas 2 MED SSR-exposed skin showed a significant number of TT-CPD. The sunscreen covered skin exposed to 15 MED appeared highly protected from DNA damage, as the amount of CPD-dimers remained below the detection limit. The multiphoton-immunostaining analysis consistently showed that no CPD staining was observed on the non-SSR-exposed skin. A significant increase of CPD staining intensity and number of CPD-positive cells were observed on the 2 MED SSR-exposed skin. Sunscreen protected skin presented a very low staining intensity and the number of CPD-positive cells remained very close to non-SSR-exposed skin. This study showed that suction blister samples are very appropriate for measuring CPD dimers in-vivo, and that sunscreens provide high protection against UVR-induced DNA damage. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Gage for gas flow measurement especially in gas-suction pipes

    International Nuclear Information System (INIS)

    Renner, K.; Stegmanns, W.

    1978-01-01

    The gage utilizes the differential pressure given by a differential pressure producer to generate, in a bypass, a partial gas flow measured by means of a direct-reading anemometer of windmill type. The partial gas flow is generated between pressure pick-up openings in the gas-suction pipe in front of a venturi insert and pressure pick-up openings at the bottleneck of the venturi insert. The reading of the anemometer is proportional to the main gas flow and independent of the variables of state and the properties of the gases to be measured. (RW) [de

  15. Entropy Generation in a Rotating Couette Flow with Suction/Injection

    Directory of Open Access Journals (Sweden)

    S. Das

    2015-05-01

    Full Text Available The present paper is concerned with an analytical study of entropy generation in viscous incompressible Couette flow with suction/injection in a rotating frame of reference. One of the plate is held at rest and the other one moves with an uniform velocity.The flow induced by the moving plate. An exact solution of governing equations has been obtained in closed form. The entropy generation number and the Bejan number are also obtained. The influences of each of the governing parameters on velocity, temperature, entropy generation and Bejan number are discussed with the help of graphs.

  16. Analgesic efficacy of lidocaine for suction-assisted lipectomy with tumescent technique under general anesthesia: a randomized, double-masked, controlled trial.

    Science.gov (United States)

    Danilla, Stefan; Fontbona, Montserrat; de Valdés, Victoria Diaz; Dagnino, Bruno; Sorolla, Juan Pablo; Israel, Guillermo; Searle, Susana; Norambuena, Hernán; Cabello, Rodrigo

    2013-08-01

    Suction-assisted lipectomy is one of the most common procedures performed in plastic surgery. To minimize blood loss and to obtain adequate analgesia, a liquid solution is infiltrated into the subcutaneous plane before suction. The objective of this study was to determine whether the use of lidocaine in the infiltration solution reduces postoperative pain. A prospective, randomized, double-masked, clinical trial was designed. Each side of patients' body zones to be treated with suction-assisted lipectomy was randomized to receive infiltration solution with or without lidocaine. Treatment allocation was performed using computer-generated random numbers in permuted blocks of eight. Pain was assessed using the visual analogue scale and registered 1, 6, 12, 18, and 24 hours after the procedure. The trial was stopped after a first interim analysis. The use of lidocaine in the dilute solution reduced pain by 0.5 point on the visual analogue scale (95 percent CI, 0.3 to 0.8; p<0.001). The effect was independent of the suctioned body zone (p=0.756), and lasted until 18 hours after surgery. Its analgesic effect was lost at the 24-hour postoperative control. Pain increased an average of 0.018 point on the visual analogue scale per hour (95 percent CI, 0.001 to 0.036; p=0.043). The use of lidocaine in the infiltration solution is effective in postoperative pain control until 18 hours after surgery. Nevertheless, its clinical effect is limited and clinically irrelevant, and therefore it is no longer used by the authors. Therapeutic, I.

  17. 85,000-GPM, single-stage, single-suction LMFBR intermediate centrifugal pump

    International Nuclear Information System (INIS)

    Fair, C.E.; Cook, M.E.; Huber, K.A.; Rohde, R.

    1983-01-01

    The mechanical and hydraulic design features of the 85,000-gpm, single-stage, single-suction pump test article, which is designed to circulate liquid-sodium coolant in the intermediate heat-transport system of a Large-Scale Liquid Metal Fast Breeder Reactor (LS-LMFBR), are described. The design and analytical considerations used to satisfy the pump performance and operability requirements are presented. The validation of pump hydraulic performance using a hydraulic scale-model pump is discussed, as is the featute test for the mechanical-shaft seal system

  18. A comparison of commercial light-emitting diode baited suction traps for surveillance of Culicoides in northern Europe.

    Science.gov (United States)

    Hope, Andrew; Gubbins, Simon; Sanders, Christopher; Denison, Eric; Barber, James; Stubbins, Francesca; Baylis, Matthew; Carpenter, Simon

    2015-04-22

    The response of Culicoides biting midges (Diptera: Ceratopogonidae) to artificial light sources has led to the use of light-suction traps in surveillance programmes. Recent integration of light emitting diodes (LED) in traps improves flexibility in trapping through reduced power requirements and also allows the wavelength of light used for trapping to be customized. This study investigates the responses of Culicoides to LED light-suction traps emitting different wavelengths of light to make recommendations for use in surveillance. The abundance and diversity of Culicoides collected using commercially available traps fitted with Light Emitting Diode (LED) platforms emitting ultraviolet (UV) (390 nm wavelength), blue (430 nm), green (570 nm), yellow (590 nm), red (660 nm) or white light (425 nm - 750 nm with peaks at 450 nm and 580 nm) were compared. A Centre for Disease Control (CDC) UV light-suction trap was also included within the experimental design which was fitted with a 4 watt UV tube (320-420 nm). Generalised linear models with negative binomial error structure and log-link function were used to compare trap abundance according to LED colour, meteorological conditions and seasonality. The experiment was conducted over 49 nights with 42,766 Culicoides caught in 329 collections. Culicoides obsoletus Meigen and Culicoides scoticus Downes and Kettle responded indiscriminately to all wavelengths of LED used with the exception of red which was significantly less attractive. In contrast, Culicoides dewulfi Goetghebuer and Culicoides pulicaris Linnaeus were found in significantly greater numbers in the green LED trap than in the UV LED trap. The LED traps collected significantly fewer Culicoides than the standard CDC UV light-suction trap. Catches of Culicoides were reduced in LED traps when compared to the standard CDC UV trap, however, their reduced power requirement and small size fulfils a requirement for trapping in logistically challenging areas or where many

  19. A Prospective Randomized Study Comparing Manual and Wall Suction in the Performance of Bronchoalveolar Lavage.

    Science.gov (United States)

    Seijo, Luis M; Flandes, Javier; Somiedo, Maria V; Naya, Alba; Manjón, Josefina; Álvarez, Susana; Fernández-Navamuel, Iker

    2016-01-01

    Bronchoalveolar lavage (BAL) may be performed using a hand-held syringe or wall suction. The aim was to study BAL volume and diagnostic yields based on BAL technique. A total of 220 consecutive patients undergoing BAL at our center were included. Manual aspiration was performed in 115 patients (group 1), and wall suction (<50 mm Hg of negative pressure) was used in 105 patients (group 2). All bronchoscopies were performed under conscious sedation applying topical anesthesia with lidocaine. Three 50-ml sterile saline aliquots were instilled in all patients. The mean total amount of fluid recovered was 67 ± 20 ml in group 1 and 55 ± 22 ml in group 2 (p < 0.001). More patients in the manual aspiration group met American Thoracic Society criteria (recovery of ≥30% of instilled fluid) for an optimal BAL (81 vs. 59%; p < 0.001). The quantity of recovered fluid was also related to BAL location (p < 0.001) and radiologic findings (p = 0.002). Forty-eight (22%) BALs were diagnostic (23 in group 1 and 25 in group 2), including 37 positive bacterial cultures, 6 positive stains for Pneumocystis, and 5 cases of malignancy. No statistically significant difference in diagnostic yield was observed between the two groups. A BAL diagnosis was more likely in patients with certain radiologic (p = 0.033) and endoscopic findings (p = 0.001). When taking into account all bronchoscopic techniques performed during the procedure (e.g. biopsies, brushing, etc.), bronchoscopy was diagnostic in 37% of patients. Manual aspiration is superior to wall suction during BAL yielding a larger quantity of aspirate. Diagnostic yields are similar for both techniques. © 2016 S. Karger AG, Basel.

  20. Dispersion of suspended material from an operating sand suction dredge in the Øresund (Denmark)

    DEFF Research Database (Denmark)

    Kiørboe, Thomas; Møhlenberg, F.

    1981-01-01

    The concentration of suspended material in the immediate vicinity of an operating sand suction dredge in the Oresund was 3-5000mg/l. Concentrations > 100 mg/l were restricted to a downstream distance of .apprx. 150m and ambient levels were reached within .apprx. 1 km of the dredge. The natural...

  1. Capillary Suction Time. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    Science.gov (United States)

    Wooley, John F.

    Capillary suction time is time required for the liquid phase of a treated sludge to travel through 1 centimeter of media (blotter or filter paper). Designed for individuals who have completed National Pollutant Discharge Elimination System (NPDES) level 1 laboratory training skills, this module provides waste water treatment plant operators with…

  2. Potential risk for bacterial contamination in conventional reused ventilator systems and disposable closed ventilator-suction systems.

    Science.gov (United States)

    Li, Ya-Chi; Lin, Hui-Ling; Liao, Fang-Chun; Wang, Sing-Siang; Chang, Hsiu-Chu; Hsu, Hung-Fu; Chen, Sue-Hsien; Wan, Gwo-Hwa

    2018-01-01

    Few studies have investigated the difference in bacterial contamination between conventional reused ventilator systems and disposable closed ventilator-suction systems. The aim of this study was to investigate the bacterial contamination rates of the reused and disposable ventilator systems, and the association between system disconnection and bacterial contamination of ventilator systems. The enrolled intubated and mechanically ventilated patients used a conventional reused ventilator system and a disposable closed ventilator-suction system, respectively, for a week; specimens were then collected from the ventilator circuit systems to evaluate human and environmental bacterial contamination. The sputum specimens from patients were also analyzed in this study. The detection rate of bacteria in the conventional reused ventilator system was substantially higher than that in the disposable ventilator system. The inspiratory and expiratory limbs of the disposable closed ventilator-suction system had higher bacterial concentrations than the conventional reused ventilator system. The bacterial concentration in the heated humidifier of the reused ventilator system was significantly higher than that in the disposable ventilator system. Positive associations existed among the bacterial concentrations at different locations in the reused and disposable ventilator systems, respectively. The predominant bacteria identified in the reused and disposable ventilator systems included Acinetobacter spp., Bacillus cereus, Elizabethkingia spp., Pseudomonas spp., and Stenotrophomonas (Xan) maltophilia. Both the reused and disposable ventilator systems had high bacterial contamination rates after one week of use. Disconnection of the ventilator systems should be avoided during system operation to decrease the risks of environmental pollution and human exposure, especially for the disposable ventilator system. ClinicalTrials.gov PRS / NCT03359148.

  3. Numerical simulation of effects of a non-ionized fluid injection and suction on the MHD flow in a circular channel

    International Nuclear Information System (INIS)

    Rahimi Eosboee, M.; Pourmahmoud, N.; Mirzaie, I.; Mohajeri Khameneh, P.; Majidyfar, S.

    2012-01-01

    Control of a fluid flow velocity profile by injection and suction of a non-ionized fluid in presence of a uniform steady magnetic field has important technical applications. In this paper, the unsteady incompressible and viscous conducting fluid flow has been investigated in a circular channel. The channel walls are assumed to be non-conducting and porous. They are subjected to a uniform steady magnetic field which is perpendicular to the axis of channel, then and suction and injection are applied at the walls. The well known equations of Magnetohydrodynamics are governed to the motion of an electrically conducting fluid flow that is subjected to magnetic field. The numerical solution is carried out by finite difference approach. The results of present numerical simulation shown that the flow injection and suction through the wall can be controlled effectively, the main flow in channel especially in industrial purposes. The results are obtained for different values of the injected and sucked non-ionized flow rate and the effect of Hartman number on the velocity profile is investigated. Finally, a good agreement is seen between the presented results and the corresponding data of finite element method.

  4. Impeller radial force evolution in a large double-suction centrifugal pump during startup at the shut-off condition

    International Nuclear Information System (INIS)

    Zou, Zhichao; Wang, Fujun; Yao, Zhifeng; Tao, Ran; Xiao, Ruofu; Li, Huaicheng

    2016-01-01

    Highlights: • Conclude the characteristics of transient radial force in the startup process for a large double-suction centrifugal pump. • The overall direction of the radial force during startup process is also confirmed. • A formula used to calculate the transient radial force during startup process is proposed. • A relationship between radial force variation and axial vortex development in blade channel during the startup process is established. The mechanism of the radial force evolution is revealed. - Abstract: Double-suction centrifugal pumps play an important role in the main feedwater systems of nuclear power plant. The impeller radial force in a centrifugal pump varies dramatically during startup at the shut-off condition. In this study, the startup process of a large double-suction centrifugal pump is investigated using CFD. During testing, the impeller speed is accelerated from zero to its rated speed in 1.0 s (marked as t_0) and is then maintained at the rated speed. The results show that the radial force increase lags behind the impeller speed increase. At 0–0.4t_0, the radial force is small (approaching zero). At 0.4–1.4t_0, the radial force increases rapidly. After 1.4t_0, the average radial force stabilizes and reaches its maximum value of 55,619 N. The observed maximum radial force value during startup is approximately nine times as high as the radial force under rated condition. During startup, the overall radial force direction is proximate to the radial line located 25° from the volute tongue along circumferential direction. A transient radial force formula is proposed to evaluate the changes in radial force during startup. The streamline distribution in impeller passages and the impeller outlet pressure profile varying over time are produced. The relationship between radial force evolution and the varying axial-to-spiral vortex structure is analyzed. The radial force change mechanism is revealed. This research provides a scientific

  5. Impeller radial force evolution in a large double-suction centrifugal pump during startup at the shut-off condition

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Zhichao [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Wang, Fujun, E-mail: wangfj@cau.edu.cn [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Yao, Zhifeng [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Tao, Ran [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Xiao, Ruofu [College of Water Resources and Civil Engineering, China Agricultural University, Beijing 100083 (China); Beijing Engineering Research Center of Safety and Energy Saving Technology for Water Supply Network System, China Agricultural University, Beijing 100083 (China); Li, Huaicheng [Shanghai Liancheng (Group) Co., Ltd., Shanghai 201812 (China)

    2016-12-15

    Highlights: • Conclude the characteristics of transient radial force in the startup process for a large double-suction centrifugal pump. • The overall direction of the radial force during startup process is also confirmed. • A formula used to calculate the transient radial force during startup process is proposed. • A relationship between radial force variation and axial vortex development in blade channel during the startup process is established. The mechanism of the radial force evolution is revealed. - Abstract: Double-suction centrifugal pumps play an important role in the main feedwater systems of nuclear power plant. The impeller radial force in a centrifugal pump varies dramatically during startup at the shut-off condition. In this study, the startup process of a large double-suction centrifugal pump is investigated using CFD. During testing, the impeller speed is accelerated from zero to its rated speed in 1.0 s (marked as t{sub 0}) and is then maintained at the rated speed. The results show that the radial force increase lags behind the impeller speed increase. At 0–0.4t{sub 0}, the radial force is small (approaching zero). At 0.4–1.4t{sub 0}, the radial force increases rapidly. After 1.4t{sub 0}, the average radial force stabilizes and reaches its maximum value of 55,619 N. The observed maximum radial force value during startup is approximately nine times as high as the radial force under rated condition. During startup, the overall radial force direction is proximate to the radial line located 25° from the volute tongue along circumferential direction. A transient radial force formula is proposed to evaluate the changes in radial force during startup. The streamline distribution in impeller passages and the impeller outlet pressure profile varying over time are produced. The relationship between radial force evolution and the varying axial-to-spiral vortex structure is analyzed. The radial force change mechanism is revealed. This research

  6. Bottom Feeding and Beyond: How the Premaxillary Protrusion of Cypriniforms Allowed for a Novel Kind of Suction Feeding.

    Science.gov (United States)

    Hernandez, L Patricia; Staab, Katie Lynn

    2015-07-01

    While much of the functional work on suction feeding has involved members of Acanthopterygii, an earlier cypriniform radiation led to over 3200 species filling nearly every freshwater trophic niche. Within the great majority of acanthomorph clades that have been investigated suction feeding and the underlying morphology responsible for the generation of rapid suction have been largely conserved. This conserved feeding-apparatus is often associated with increasing the force experienced by the prey item, thus making a strike on elusive prey more effective. Cypriniforms' trophic anatomy is comprised of a number of novelties used for benthic feeding, which characterized early members of this clade. The modified cypriniform structure of the oral jaws represents a situation in which a particular type of suction feeding allowed for probing the benthos with a more functionally maneuverable anatomy. Requisite evolutionary modifications included origin and elongation of a median kinethmoid, duplications of certain divisions of the muscles of the adductor mandibulae, and origin of a dorsal, intra-buccal muscular palatal organ used in winnowing detritus. The elongated kinethmoid (coupled with modified adductor muscles) allowed for a type of premaxillary protrusion that decoupled the upper and lower jaws, enabled premaxillary protrusions with a closed mouth, and facilitated benthic feeding by increasing functional flexibility. The resultant flow of fluid generated by cypriniforms is also quite flexible, with multiple instances of peak flow in a single feeding event. This greatly modified morphology allowed for a degree of kinematic maneuverability not seen within most acanthomorphs. Later cypriniform radiations into piscivorous, insectivorous, or planktivorous feeding guilds were associated with shortening of the kinethmoid and with simplified morphology of the adductor, likely involving an emphasis on ram feeding. Although this suite of morphological novelties seemingly

  7. Laterally Loaded Single Pile Response Considering the Influence of Suction and Non-Linear Behaviour of Reinforced Concrete Sections

    Directory of Open Access Journals (Sweden)

    Stefano Stacul

    2017-12-01

    Full Text Available A hybrid BEM-p-y curves approach was developed for the single pile analysis with free/fixed head restraint conditions. The method considers the soil non-linear behaviour by means of p-y curves in series to a multi-layered elastic half-space. The non-linearity of reinforced concrete pile sections, also considering the influence of tension-stiffening, has been considered. The model reproduces the influence of suction by increasing the stress state and hence the stiffness of shallow soil-layers. Suction is modeled using the Modified-Kovacs model. The hybrid BEM-py curves method was validated by comparing results from data of 22 load tests on single piles. In addition, a detailed comparison is presented between measured and computed data on a large-diameter reinforced concrete bored single pile.

  8. The impact analysis of the connecting pipe length and diameter on the operation of a piston hybrid power machine of positive displacement with gas suction capacity

    Science.gov (United States)

    Shcherba, V. E.; Grigoriev, A. V.; Averyanov, G. S.; Surikov, V. I.; Vedruchenko, V. P.; Galdin, N. S.; Trukhanova, D. A.

    2017-08-01

    The article analyzes the impact of the connecting liquid pipe length and diameter on consumables and power characteristics of the piston hybrid power machine with gas suction capacity. The following operating characteristics of the machine were constructed and analyzed: the average height of the liquid column in the jacket space; instantaneous velocity and height of the liquid column in the jacket space; the relative height of the liquid column in the jacket space; volumetric efficiency; indicator isothermal efficiency; flowrate in the pump section; relative pressure losses during suction; relative flowrate. The dependence of the instantaneous pressure in the work space and the suction space of the compressor section on the rotation angle of the crankshaft is determined for different values of the length and diameter of the connecting pipeline.

  9. Heat performance resulting from combined effects of radiation and mixed convection in a rectangular cavity ventilated by injection or suction

    Science.gov (United States)

    Ezzaraa, K.; Bahlaoui, A.; Arroub, I.; Raji, A.; Hasnaoui, M.; Naïmi, M.

    2018-05-01

    In this work, we investigated numerically heat transfer by mixed convection coupled to thermal radiation in a vented rectangular enclosure uniformly heated from below with a constant heat flux. The fresh fluid is admitted into the cavity by injection or suction, by means of two openings located on the lower part of both right and left vertical sides. Another opening is placed on the middle of the top wall to ensure the ventilation. Air, a radiatively transparent medium, is considered to be the cooling fluid. The inner surfaces, in contact with the fluid, are assumed to be gray, diffuse emitters and reflectors of radiation with identical emissivities. The effects of some pertinent parameters such as the Reynolds number, 300 ≤ Re ≤ 5000, and the emissivity of the walls, 0 ≤ ɛ ≤ 0.85, on flow and temperature patterns as well as on the heat transfer rate within the enclosure are presented for the two ventilation modes (injection and suction). The results indicate that the flow and thermal structures are affected by the thermal radiation for the two modes of imposed flow. However, the suction mode is found to be more favorable to the heat transfer in comparison with the injection one.

  10. Aphids of the genus Diuraphis caught by Johnson suction trap in Poznań, Poland

    Directory of Open Access Journals (Sweden)

    Strażyński Przemysław

    2016-12-01

    Full Text Available In 1973-2011 in Poznań, aphid catches were carried out using Johnson’s suction trap. Since then the suction trap located at the Institute of Plant Protection - National Research Institute in Poznań has continuously recorded the daily and seasonal dynamics of aphid flights. The collected results has been used to establish one of the largest databases of this type in Europe. The data also allow tracking changes in aphid biodiversity under the changing climatic conditions. Three aphid species of Diuraphis spp. were identified: D. muehlei (Börner, 1950 - in 1974, D. bromicola (Hille Ris Lambers, 1959 - in 1988, D. noxia (Kurdjumov, 1913 - in 2003 as a result of systematic and long-term aphid collections. The occurrence of D. noxia presents a particular risk to cereal crops in Poland. This expansive aphid species that originates from Asia and the Mediterranean is a vector of Barley yellow dwarf viruses (BYDV, and has become one of the most important pest of wheat and barley in the world. Changes in climatic conditions that have been observed in recent years in Poland such as hot summer, long and warm autumn, mild winter seem to be optimal for occurrence and development of aphid species from warmer parts of Europe.

  11. Comparison between autologous blood transfusion drainage and closed-suction drainage/no drainage in total knee arthroplasty: a meta-analysis.

    Science.gov (United States)

    Hong, Kun-Hao; Pan, Jian-Ke; Yang, Wei-Yi; Luo, Ming-Hui; Xu, Shu-Chai; Liu, Jun

    2016-08-01

    Autologous blood transfusion (ABT) drainage system is a new unwashed salvaged blood retransfusion system for total knee replacement (TKA). However, whether to use ABT drainage, closed-suction (CS) drainage or no drainage in TKA surgery remains controversial. This is the first meta-analysis to assess the clinical efficiency, safety and potential advantages regarding the use of ABT drains compared with closed-suction/no drainage. PubMed, Embase, and the Cochrane Library were comprehensively searched in March 2015. Fifteen randomized controlled trials (RCTs) were identified and pooled for statistical analysis. The primary outcome evaluated was homologous blood transfusion rate. The secondary outcomes were post-operative haemoglobin on days 3-5, length of hospital stay and wound infections after TKA surgery. The pooled data included 1,721 patients and showed that patients in the ABT drainage group might benefit from lower blood transfusion rates (16.59 % and 37.47 %, OR: 0.28 [0.14, 0.55]; 13.05 % and 16.91 %, OR: 0.73 [0.47,1.13], respectively). Autologous blood transfusion drainage and closed-suction drainage/no drainage have similar clinical efficacy and safety with regard to post-operative haemoglobin on days 3-5, length of hospital stay and wound infections. Autologous blood transfusion drainage offers a safe and efficient alternative to CS/no drainage with a lower blood transfusion rate. Future large-volume high-quality RCTs with extensive follow-up will affirm and update this system review.

  12. Diagnostic Value of Endometrial Sampling with Pipelle Suction Curettage for Identifying Endometrial Lesions in Patients with Abnormal Uterine Bleeding

    Directory of Open Access Journals (Sweden)

    F Behnamfar

    2004-06-01

    Full Text Available Background: While determining the cause of abnormal uterine bleeding, sampling from the endometrium is necessary. Considering that pipelle suction curettage can be performed on an out patient basis and does not require hospitalization, using anesthesia and cervical dilatation, we performed this study. The aim of this study was to compare the diagnostic value of dilatation and curettage (D&C with pipelle suction curettage. Methods: This study was quasiexperimental on 200 pre and postmenopausal patients with abnormal uterine bleeding who refered to Shabihkhani hospital in Kashan, Iran. Endometrial sampling was performed in all patients with two methods namely pipelle and D&C. A pathologist examined the samples each having a predetermined code. Results: The mean age of subjects was 46.2 ±6.2 years, minimum age was 35 years and the maximum was 70 years. The various pathological lab findings were proliferative endometrium, secretory endometrium, athrophic, decidua, cystic and adenomatous hyperplasia. The reports were the same in two methods except for 2 cases where they were different: secretory endometrium with D&C but cystic hyperplasia in pipelle method. Conclusions: The result of our study shows the comparability of obtaining endometrial sample by pipelle with D&C. Due to comfort and convenience of patients in pipelle methode especially in the office setting which does not need anesthesia, pipelle method can easily be employed instead of D&C. Keywords: Pipelle Suction Curette, Dilatation and Curettage, Premenopause, Postmenopause.

  13. Unsteady flow of an incompressible fluid in a horizontal porous medium with suction

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1988-04-01

    A theoretical analysis of two-dimensional unsteady flow in a porous medium bounded by a horizontal wall is presented as a perturbation on a basic flow. It is assumed that the perturbation is occasioned by a sudden suction at the wall. Even for a highly permeable medium the characteristic Reynolds number in porous media flow is usually small and asymptotic solutions are developed by the Laplace transform technique. It is observed that the perturbed shear stress at the wall decays exponentially with time. (author). 5 refs

  14. High negative pressure subcutaneous suction drain for managing debilitating subcutaneous emphysema secondary to tube thoracostomy for an iatrogenic post computed tomography guided transthoracic needle biopsy pneumothorax: Case report and review of literature.

    Science.gov (United States)

    Ahmed, Zeeshan; Patel, Pinakin; Singh, Suresh; Sharma, Raj Govind; Somani, Pankaj; Gouri, Abdul Rauf; Singh, Shiv

    2016-01-01

    Subcutaneous emphysema is a common complication of tube thoracostomy. Though self-limiting, it should be treated when it causes palpebral closure, dyspnea, dysphagia or undue disfigurement resulting in anxiety and distress to the patient. A 72year old man who was a known case of COPD on bronchodilators developed a large pneumothorax and respiratory distress after a CT guided transthoracic lung biopsy done for a lung opacity (approx. 3×3cm) at the right hilar region on Chest X-ray. Within 24h of an urgent tube thoracostomy, patient developed intractable subcutaneous emphysema with closure of palpebral fissure and dyspnea unresponsive to increasing suction on chest tube. A subcutaneous fenestrated drain was placed mid-way between the nipple and clavicle in the mid-clavicular line bilaterally. Continuous negative suction (-150mmHg) resulted in immediate, sustained relief and complete resolution within 5days. Extensive and debilitating SE (subcutaneous emphysema) has to be treated promptly to relieve patient discomfort, dysphagia or imminent respiratory compromise. A variety of treatment have been tried including infraclavicular blow-hole incisions, subcutaneous drains +/- negative pressure suction, fenestrated angiocatheters, Vacuum assisted dressings and increasing suction on a pre-existing chest tube. We describe a high negative pressure subcutaneous suction drain which provides immediate and sustained relief in debilitating SE. Debilitating subcutaneous emphysema which causes distress, anxiety, palpebral closure, dyspnoea or dysphagia requires intervention. High negative pressure subcutaneous suction drain provides immediate and sustained relief in extensive and debilitating SE. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Controlling the Flow past a Semicircular Airfoil at Zero Angle of Attack Using Slot Suction in One or Two Vortex Cells for Attaining Extremal Lift

    Science.gov (United States)

    Isaev, S. A.; Baranov, P. A.; Sudakov, A. G.; Popov, I. A.; Usachov, A. E.

    2017-12-01

    Calculations using multiblock computational technologies and a model of shear-stress transport modified with allowance for the curvature of streamlines in turbulent airflow were performed at a zero angle of attack for a semicircular airfoil containing one or two surface vortex cells with slot suction. The results showed evidence of stabilization of a nearly undetached flow and attainment of an extremal lift of C y = 5.2 and a lift-to-drag ratio of K = 24 with allowance for energy losses for suction in the vortex cells.

  16. History of Suction-Type Laminar-Flow Control with Emphasis on Flight Resrearch: Monographs in Aerospace History Number 13

    Science.gov (United States)

    Braslow, A. L.

    1999-01-01

    The paper contains the following sections: Foreword; Preface; Laminar-Flow Control Concepts and Scope of Monograph; Early Research on Suction-Type Laminar-Flow Control (Research from the 1930s through the War Years; Research from after World War II to the Mid-1960s); Post X-21 Research on Suction-Type Laminar-Flow Control; Status of Laminar-Flow Control Technology in the Mid-1990s; Glossary; Document 1-Aeronautics Panel, AACB, R&D Review, Report of the Subpanel on Aeronautic Energy Conservation/Fuels; Document 2-Report of Review Group on X-21A Laminar Flow Control Program; Document 3-Langley Research Center Announcement, Establishment of Laminar Flow Control Working Group; Document 4-Intercenter Agreement for Laminar Flow Control Leading Edge Glove Flights, LaRC and DFRC; Document 5-Flight Report NLF-144, of AFTIF-111 Aircraft with the TACT Wing Modified by a Natural Laminar Flow Glove; Document 6-Flight Record, F-16XL Supersonic Laminar Flow Control Aircraft; Index; and About the Author.

  17. Suction blister grafting - Modifications for easy harvesting and grafting

    Directory of Open Access Journals (Sweden)

    2012-01-01

    Full Text Available Suction blister grafting is a simple modality of treatment of patients with resistant and stable vitiligo. But raising the blisters may be time consuming and transferring to the recipient site may be difficult as the graft is ultrathin. By doing some modifications we can make the technique simpler and easier. We can decrease the blister induction time by intradermal injection of saline, exposure to Wood′s lamp, intrablister injection of saline. By these methods we can decrease the blister induction time from 2-3 hrs to 45-90 minutes. After harvesting the graft, it can be transferred to the recipient area by taking the graft on a sterile glass slide, on the gloved finger, rolling the graft over a sterile syringe and then spreading on the recipient area, or taking on the sterile wrapper of paraffin dressing and then placing over the recipient area.

  18. Fastest predators in the plant kingdom: functional morphology and biomechanics of suction traps found in the largest genus of carnivorous plants

    Science.gov (United States)

    Poppinga, Simon; Weisskopf, Carmen; Westermeier, Anna Sophia; Masselter, Tom; Speck, Thomas

    2016-01-01

    Understanding the physics of plant movements, which describe the interplay between plant architecture, movement speed and actuation principles, is essential for the comprehension of important processes like plant morphogenesis. Recent investigations especially on rapid plant movements at the interface of biology, physics and engineering sciences highlight how such fast motions can be achieved without the presence of muscles, nerves and technical hinge analogies. The suction traps (bladders) of carnivorous bladderworts (Utricularia spp., Lentibulariaceae, Lamiales) are considered as some of the most elaborate moving structures in the plant kingdom. A complex interplay of morphological and physiological adaptations allows the traps to pump water out of their body and to store elastic energy in the deformed bladder walls. Mechanical stimulation by prey entails opening of the otherwise watertight trapdoor, followed by trap wall relaxation, sucking in of water and prey, and consecutive trapdoor closure. Suction can also occur spontaneously in non-stimulated traps. We review the current state of knowledge about the suction trap mechanism with a focus on architectonically homogeneous traps of aquatic bladderwort species from section Utricularia (the so-called ‘Utricularia vulgaris trap type’). The functional morphology and biomechanics of the traps are described in detail. We discuss open questions and propose promising aspects for future studies on these sophisticated ultra-fast trapping devices. PMID:26602984

  19. An Iterative Method to Derive the Equivalent Centrifugal Compressor Performance at Various Operating Conditions: Part I: Modelling of Suction Parameters Impact

    Directory of Open Access Journals (Sweden)

    Waleed Albusaidi

    2015-08-01

    Full Text Available This paper introduces a new iterative method to predict the equivalent centrifugal compressor performance at various operating conditions. The presented theoretical analysis and empirical correlations provide a novel approach to derive the entire compressor map corresponding to various suction conditions without a prior knowledge of the detailed geometry. The efficiency model was derived to reflect the impact of physical gas properties, Mach number, and flow and work coefficients. One of the main features of the developed technique is the fact that it considers the variation in the gas properties and stage efficiency which makes it appropriate with hydrocarbons. This method has been tested to predict the performance of two multistage centrifugal compressors and the estimated characteristics are compared with the measured data. The carried comparison revealed a good matching with the actual values, including the stable operation region limits. Furthermore, an optimization study was conducted to investigate the influences of suction conditions on the stage efficiency and surge margin. Moreover, a new sort of presentation has been generated to obtain the equivalent performance characteristics for a constant discharge pressure operation at variable suction pressure and temperature working conditions. A further validation is included in part two of this study in order to evaluate the prediction capability of the derived model at various gas compositions.

  20. Exact solution for flow in a porous pipe with unsteady wall suction and/or injection

    Science.gov (United States)

    Tsangaris, S.; Kondaxakis, D.; Vlachakis, N. W.

    2007-10-01

    This paper presents an extension of the exact solution of the steady laminar axisymmetric flow in a straight pipe of circular cross section with porous wall, given by R.M. Terrill, to the case of unsteady wall injection and/or suction. The cases of the pulsating parabolic profile and of the developed pulsating flow are investigated as examples. The pulsating flow in porous ducts has many applications in biomedical engineering and in other engineering areas.

  1. Some Exact Solutions of Boundary Layer Flows along a Vertical Plate with Buoyancy Forces Combined with Lorentz Forces under Uniform Suction

    Directory of Open Access Journals (Sweden)

    Asterios Pantokratoras

    2008-01-01

    Full Text Available Exact analytical solutions of boundary layer flows along a vertical porous plate with uniform suction are derived and presented in this paper. The solutions concern the Blasius, Sakiadis, and Blasius-Sakiadis flows with buoyancy forces combined with either MHD Lorentz or EMHD Lorentz forces. In addition, some exact solutions are presented specifically for water in the temperature range of 0∘C≤≤8∘C, where water density is nearly parabolic. Except for their use as benchmarking means for testing the numerical solution of the Navier-Stokes equations, the presented exact solutions with EMHD forces have use in flow separation control in aeronautics and hydronautics, whereas the MHD results have applications in process metallurgy and fusion technology. These analytical solutions are valid for flows with strong suction.

  2. 75 FR 3731 - Proposed Issuance of a General NPDES Permit for Small Suction Dredging-Permit Number IDG-37-0000

    Science.gov (United States)

    2010-01-22

    ... System (NPDES) general permit to placer mining operations in Idaho for small suction dredges (intake... ENVIRONMENTAL PROTECTION AGENCY [FRL-9104-3] Proposed Issuance of a General NPDES Permit for Small... significant economic impact on a substantial number of small entities.'' EPA has concluded that NPDES general...

  3. Effect of thermal radiation and suction on convective heat transfer of nanofluid along a wedge in the presence of heat generation/absorption

    Energy Technology Data Exchange (ETDEWEB)

    Kasmani, Ruhaila Md; Bhuvaneswari, M. [Centre for Foundation Studies in Science, University of Malaya, 50603 Kuala Lumpur (Malaysia); Sivasankaran, S.; Siri, Zailan [Institute of Mathematical Science, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2015-10-22

    An analysis is presented to find the effects of thermal radiation and heat generation/absorption on convection heat transfer of nanofluid past a wedge in the presence of wall suction. The governing partial differential equations are transformed into a system of ordinary differential equations using similarity transformation. The resulting system is solved numerically using a fourth-order Runge–Kutta method with shooting technique. Numerical computations are carried out for different values of dimensionless parameters to predict the effects of wedge angle, thermophoresis, Brownian motion, heat generation/absorption, thermal radiation and suction. It is found that the temperature increases significantly when the value of the heat generation/absorption parameter increases. But the opposite observation is found for the effect of thermal radiation.

  4. Design of triaxial test with controlled suction: measure of strain

    International Nuclear Information System (INIS)

    Gasc-Barbier, M.; Cosenza, Ph.; Ghoreychi, M.; Chanchole, S.; Cosenza, Ph.; Tessier, D.

    2000-01-01

    Experimental study of mechanical behavior of clayey materials under hygrometric condition is usually performed either on unloaded samples or by means of classical odometer tests used in soil mechanics. Such methods are not well adapted to hard deep clayey rocks with little deformability, porosity and permeability. Moreover, stress and strain tensors having a significant effect on hygro-mechanical behaviour and properties cannot be measured and investigated appropriately by classical tests. This is why a specific triaxial test was designed in which the sample is surrounded by a fiber glass tissue allowing air circulation and then by silicon on which confining pressure is applied. Thus, equilibrium between air and sample was reduced. Stress and strain tensors were also measured in time on the sample subjected to a mechanical loading and to a controlled suction. After presentation of the test, preliminary results are given. (authors)

  5. How propeller suction is the dominant factor for ship accidents at shallow water conditions

    Science.gov (United States)

    Acar, Dursun; Alpar, Bedri; Ozeren, Sinan

    2017-04-01

    The laminar flow comes to the fore with the disappearance of the several other directions in the internal displacements in the water current. Due to the dominant speed direction during the straightforward motion of the ship, the underwater hull is associated with the continuous flow of laminar currents. The open marine environment acts as a compressible liquid medium because of the presence of many variables about water volume overflow boundaries where the ship is associated. Layers of water rising over the sea surface due to ship's body and the propeller's water push provides loss of liquid lifting force for the ship. These situations change the well-known sea-floor morphology and reliable depth limits, and lead to probable accidents. If the ship block coefficient for the front side is 0.7 or higher, the "squat" will be more on the bow, because the associated factor "displacement volume" causes to the low-pressure environment due to large and rapid turbulence. Thus, the bow sinks further, which faced with liquid's weaker lift force. The vessels Gerardus Mercator, Queen Elizabeth and Costa Concordia had accidents because of unified reasons of squat, fast water mass displacement by hull push and propeller suction interaction. In the case of water mass displacement from the bow side away, that accident occurred in 2005 by the vessel Gerardus Mercator with excessive longitudinal trim angularity in the shallow water. The vessel Costa Concordia (2012), voluminous water displaced from the rear left side was an important factor because of the sharp manoeuvre of that the captain made before the accident. Observations before the accident indicate that full-speed sharp turn provided listed position for the ship from left (port side) in the direction of travel before colliding and then strike a rock on the sloping side of the seabed. The reason why the ship drifted to the left depends mainly the water discharge occurred at the left side of the hull during left-hand rudder

  6. Effect of Suction Nozzle Pressure Drop on the Performance of an Ejector-Expansion Transcritical CO2 Refrigeration Cycle

    Directory of Open Access Journals (Sweden)

    Zhenying Zhang

    2014-08-01

    Full Text Available The basic transcritical CO2 systems exhibit low energy efficiency due to their large throttling loss. Replacing the throttle valve with an ejector is an effective measure for recovering some of the energy lost in the expansion process. In this paper, a thermodynamic model of the ejector-expansion transcritical CO2 refrigeration cycle is developed. The effect of the suction nozzle pressure drop (SNPD on the cycle performance is discussed. The results indicate that the SNPD has little impact on entrainment ratio. There exists an optimum SNPD which gives a maximum recovered pressure and COP under a specified condition. The value of the optimum SNPD mainly depends on the efficiencies of the motive nozzle and the suction nozzle, but it is essentially independent of evaporating temperature and gas cooler outlet temperature. Through optimizing the value of SNPD, the maximum COP of the ejector-expansion cycle can be up to 45.1% higher than that of the basic cycle. The exergy loss of the ejector-expansion cycle is reduced about 43.0% compared with the basic cycle.

  7. [Comparison of the effects of the intervention with electric thermal bian stone and air suction cup on blood perfusion at meridian points].

    Science.gov (United States)

    Zhao, Pengna; Wang, Yanping; Gu, Feifei; Li, Chaozheng; Wei, Yulong; Wang, Guangjun; Zhang, Weibo

    2018-02-12

    To observe the impacts of the intervention with electric thermal bian stone and air suction cup on blood perfusion (BP) at meridian points and explore the approach of accurate measurement and regulation of meridian qi and blood balance in "precise acupuncture". The laser Doppler line scanner (LDLS) was used to measure BP at bilateral yua n-primary points at the pericardium meridian, the triple energizer meridian, the gallbladder meridian and the liver meridian (small cycle of jueyin to shaoyang meridians) at 31 healthy receptors. The bias ratio of blood perfusion (BPBR) deviated to the reference value was calculated. The electric thermal bian stone and air suction cup were used in the intervention at the he -sea points of the affected meridians in which BPBR was relatively higher at the yuan -primary points. The electric thermal bian stone therapy was used when BPBR was less than -30% and the air suction cupping therapy was used when BPBR was higher than 30%. BP was measured twice before intervention and it was measured separately at the moment after intervention and in 20 min after intervention. The means of BP before and after intervention and the change ratio of blood perfusion (BPCR) before intervention, at the moment after intervention and 20 min after intervention were calculated. 1. After the intervention of electric thermal bian stone, BP mean was increased from (103.51±41.21) PU to (121.97±56.22) PU ( P 0.05), but the change ratio was highly remained. 2. After intervention with air suction cup, BP mean was reduced from (194.83±81.14) PU to (173.88±88.26) PU. Before intervention, at the moment after intervention and 20 min after intervention, separately, BPCR were (7.62±30.49)%, (-12.12±18.20)% and (-14.35±21.25)%. BPCR at the moment after intervention and in 20 min after intervention were significantly different from that before intervention (both P cup is opposite.

  8. AUTOMATIC CONTROL SYSTEM OF THE DIFFERENCE BETWEEN DISCHARGE AND SUCTION PRESSURES OF THE HEAT PUMP STATION COMPRESSOR

    Directory of Open Access Journals (Sweden)

    Sit M.L.

    2009-04-01

    Full Text Available Possibility of realization is shown and the control system of a difference of pressure between an exit and an input of the compressor of the heat pump on carbon dioxide working at variable thermal load, and discharge and suction pressures by means of two control valves connected in series is developed. On an example a flow coefficient calculation procedure of control valves is shown.

  9. Unsteady three dimensional flow of Casson liquid film over a porous stretching sheet in the presence of uniform transverse magnetic field and suction/injection

    Energy Technology Data Exchange (ETDEWEB)

    Maity, S., E-mail: susantamaiti@gmail.com [Department of Mathematics, National Institute of Technology, Arunachal Pradesh, Yupia, Papumpare 791112 (India); Singh, S.K. [Engineering Mechanics Unit, Jawaharlal Nehru Centre for Advanced Scientific Research, Bangalore 560064 (India); Kumar, A.V. [Department of Mathematics, National Institute of Technology, Arunachal Pradesh, Yupia, Papumpare 791112 (India)

    2016-12-01

    Three dimensional flow of thin Casson liquid film over a porous unsteady stretching sheet is investigated under assumption of initial uniform film thickness. The effects of the uniform transverse magnetic field, suction and injection are also considered for investigation. The nonlinear governing set of equations and film evolution equation are solved analytically by using singular perturbation technique. It is found that the film thickness decreases with the increasing values of the Casson parameter. The Hartmann number and porosity parameter resist the film thinning process. It is also observed that the film thickness increases with the increasing values of the suction velocity whereas it decreases for increasing values of the injection velocity at the stretching surface.

  10. Beneficial effects of intermittent suction and pressure treatment in intermittent claudication

    DEFF Research Database (Denmark)

    Mehlsen, J; Himmelstrup, H; Himmelstrup, Bodil

    1993-01-01

    administration. The treatment caused significant increments in the ADP thresholds for platelet aggregation, while the effects on fibrinolysis were uncertain. It is concluded that intermittent suction and pressure treatment offers a new approach for conservative treatment of intermittent claudication....... participated in an open trial investigating the possible effects of the treatment on platelet aggregation and fibrinolysis. Pain-free and maximal walking distances were measured on a treadmill, and systolic blood pressure was measured on the upper limb, the ankle, and the first toe bilaterally. The threshold...... for adenosine diphosphate (ADP)-induced platelet aggregation was tested, and the fibrinolytic activity was estimated from the euglobulin clot lysis time. Active treatment resulted in significant improvements in pain-free and maximal walking distances, whereas no changes could be found during placebo...

  11. The radiation and variable viscosity effects on electrically conducting fluid over a vertically moving plate subjected to suction and heat flux

    Energy Technology Data Exchange (ETDEWEB)

    Malekzadeh, P., E-mail: malekzadeh@pgu.ac.i [Department of Mechanical Engineering, Persian Gulf University, Bushehr 75168 (Iran, Islamic Republic of); Center of Excellence for Computational Mechanics, Shiraz University, Shiraz (Iran, Islamic Republic of); Moghimi, M.A. [Department of Mechanical Engineering, School of Engineering, Shaid Bahonar University, Kerman (Iran, Islamic Republic of); Nickaeen, M. [K.N. Toosi University of Technology, Tehran (Iran, Islamic Republic of)

    2011-05-15

    Research highlights: {yields} A new application of the differential quadrature method in thermo-fluid fields. {yields} Moving vertical plate with suction and heat flux is considered. {yields} Fluid with variable viscosity subjected to thermal radiation is studied. -- Abstract: In this paper, firstly, the applicability of the differential quadrature method (DQM) as an efficient and accurate numerical method for solving the problem of variable viscosity and thermally radiative unsteady magneto-hydrodynamic (MHD) flow over a moving vertical plate with suction and heat flux is investigated. The spatial as well as the temporal domains are discretized using the DQM. The fast rate of convergence of the method is demonstrated and for the cases that a solution is available, comparison is done. Then, effects of the temperature dependence of viscosity and different fluid parameters on the velocity and temperature of transient MHD flow subjected to the above mentioned boundary condition are studied.

  12. Australian fur seals (Arctocephalus pusillus doriferus use raptorial biting and suction feeding when targeting prey in different foraging scenarios.

    Directory of Open Access Journals (Sweden)

    David P Hocking

    Full Text Available Foraging behaviours used by two female Australian fur seals (Arctocephalus pusillus doriferus were documented during controlled feeding trials. During these trials the seals were presented with prey either free-floating in open water or concealed within a mobile ball or a static box feeding device. When targeting free-floating prey both subjects primarily used raptorial biting in combination with suction, which was used to draw prey to within range of the teeth. When targeting prey concealed within either the mobile or static feeding device, the seals were able to use suction to draw out prey items that could not be reached by biting. Suction was followed by lateral water expulsion, where water drawn into the mouth along with the prey item was purged via the sides of the mouth. Vibrissae were used to explore the surface of the feeding devices, especially when locating the openings in which the prey items had been hidden. The mobile ball device was also manipulated by pushing it with the muzzle to knock out concealed prey, which was not possible when using the static feeding device. To knock prey out of this static device one seal used targeted bubble blowing, where a focused stream of bubbles was blown out of the nose into the openings in the device. Once captured in the jaws, prey items were manipulated and re-oriented using further mouth movements or chews so that they could be swallowed head first. While most items were swallowed whole underwater, some were instead taken to the surface and held in the teeth, while being vigorously shaken to break them into smaller pieces before swallowing. The behavioural flexibility displayed by Australian fur seals likely assists in capturing and consuming the extremely wide range of prey types that are targeted in the wild, during both benthic and epipelagic foraging.

  13. Reevaluating Musculoskeletal Linkages in Suction-Feeding Fishes with X-Ray Reconstruction of Moving Morphology (XROMM).

    Science.gov (United States)

    Camp, Ariel L; Brainerd, Elizabeth L

    2015-07-01

    Suction-feeding fishes encompass a vast diversity of morphologies and ecologies, but during feeding they all rely on musculoskeletal linkages and levers to transform the shortening of muscle into 3D expansion of the mouth cavity. To relate the shape of these skeletal elements to their function in expansion of the mouth, four-bar linkage models have been developed and widely used in studies of ecology, evolution, and development. However, we have lacked the ability to test the predictions of these 2D linkage models against the actual 3D motions of fishes' skulls. A new imaging method, X-ray Reconstruction of Moving Morphology (XROMM), now makes it possible to measure 3D skeletal motions relative to other bones within the head and relative to the fish's body, and thereby to examine directly the proposed linkages. We used XROMM to examine the opercular linkage, in which shortening of the levator operculi muscle is hypothesized to retract the operculum, and thereby the interoperculum and interoperculomandibular ligament to generate depression of the lower jaw about the quadratomandibular joint. XROMM animations of suction strikes in largemouth bass revealed that the operculum is indeed retracted relative to the suspensorium as the levator operculi muscle shortens and the jaw depresses. However, the four-bar model of this linkage overestimates the depression of the jaw by nearly a factor of two. Therefore, caution should be used in interpreting and applying the predictions of this linkage model. When we measured kinematics relative to the fish's body, we found that the operculum was relatively stable, whereas the suspensorium was elevated along with the neurocranium, pushing the quadratomandibular joint forward to produce depression of the jaw. Thus, it is the epaxial muscles elevating the neurocranium that powers depression of the jaw through the opercular linkage. However, the levator operculi muscle plays a crucial role in stabilizing the operculum to allow elevation

  14. A Numerical Study on the Improvement of Suction Performance and Hydraulic Efficiency for a Mixed-Flow Pump Impeller

    Directory of Open Access Journals (Sweden)

    Sung Kim

    2014-01-01

    Full Text Available This paper describes a numerical study on the improvement of suction performance and hydraulic efficiency of a mixed-flow pump by impellers. The design of these impellers was optimized using a commercial CFD (computational fluid dynamics code and DOE (design of experiments. The design variables of meridional plane and vane plane development were defined for impeller design. In DOE, variables of inlet part were selected as main design variables in meridional plane, and incidence angle was selected in vane plane development. The verification of the experiment sets that were generated by 2k factorial was done by numerical analysis. The objective functions were defined as the NPSHre (net positive suction head required, total efficiency, and total head of the impellers. The importance of the geometric design variables was analyzed using 2k factorial designs. The interaction between the NPSHre and total efficiency, according to the meridional plane and incidence angle, was discussed by analyzing the 2k factorial design results. The performance of optimally designed model was verified by experiments and numerical analysis and the reliability of the model was retained by comparison of numerical analysis and comparative analysis with the reference model.

  15. Aero-thermal optimization of film cooling flow parameters on the suction surface of a high pressure turbine blade

    Science.gov (United States)

    El Ayoubi, Carole; Hassan, Ibrahim; Ghaly, Wahid

    2012-11-01

    This paper aims to optimize film coolant flow parameters on the suction surface of a high-pressure gas turbine blade in order to obtain an optimum compromise between a superior cooling performance and a minimum aerodynamic penalty. An optimization algorithm coupled with three-dimensional Reynolds-averaged Navier Stokes analysis is used to determine the optimum film cooling configuration. The VKI blade with two staggered rows of axially oriented, conically flared, film cooling holes on its suction surface is considered. Two design variables are selected; the coolant to mainstream temperature ratio and total pressure ratio. The optimization objective consists of maximizing the spatially averaged film cooling effectiveness and minimizing the aerodynamic penalty produced by film cooling. The effect of varying the coolant flow parameters on the film cooling effectiveness and the aerodynamic loss is analyzed using an optimization method and three dimensional steady CFD simulations. The optimization process consists of a genetic algorithm and a response surface approximation of the artificial neural network type to provide low-fidelity predictions of the objective function. The CFD simulations are performed using the commercial software CFX. The numerical predictions of the aero-thermal performance is validated against a well-established experimental database.

  16. Cytoskeleton and pericellular matrix organization of pure adult human keratinocytes cultured from suction-blister roof epidermis.

    Science.gov (United States)

    Kariniemi, A L; Lehto, V P; Vartio, T; Virtanen, I

    1982-12-01

    Pure adult human keratinocyte cultures were raised from suction-blister roof epidermis and cultured in MCDB-151 medium. In primary culture the epidermal cells rapidly adhered, spread and began to proliferate on collagen-coated growth substrata but not on uncoated plastic or glass substrata. A fibrillar keratin-specific fluorescence, showing a typical cell-cell arrangement, was seen in all cells in indirect immunofluorescence microscopy, whereas only some cells also showed vimentin-specific staining. A fine fibrillar fibronectin-specific surface staining was seen at the margin of attaching cells and in marginal cells of spreading cell islands, whereas no fluorescence could be seen in epidermal cells, with antibodies against type IV collagen or laminin. Interestingly, the marginal cells also showed intracellular fibronectin. The synthesis of fibronectin in epidermal cell cultures could also be revealed by metabolic labelling experiments with [35S]methionine. In contrast to primary cultures, subcultivated keratinocytes also adhered to uncoated plastic and glass substrata. After subcultivation, keratin and surface fibronectin distribution remained unaltered but after some subcultivations, most of the cells also showed fibrillar vimentin and expressed fibronectin intracellularly. The results show that the suction-blister method provides an easy way to obtain pure epidermal cell cultures without contaminating mesenchymal cells. Our results also suggest a direct role for fibronectin but not for collagen type IV or laminin in adhesion and spreading of epidermal cells in vitro.

  17. Seasonal dynamics of nitrate and ammonium ion concentrations in soil solutions collected using MacroRhizon suction cups.

    Science.gov (United States)

    Kabala, Cezary; Karczewska, Anna; Gałka, Bernard; Cuske, Mateusz; Sowiński, Józef

    2017-07-01

    The aims of the study were to analyse the concentration of nitrate and ammonium ions in soil solutions obtained using MacroRhizon miniaturized composite suction cups under field conditions and to determine potential nitrogen leaching from soil fertilized with three types of fertilizers (standard urea, slow-release urea, and ammonium nitrate) at the doses of 90 and 180 kg ha -1 , applied once or divided into two rates. During a 3-year growing experiment with sugar sorghum, the concentration of nitrate and ammonium ions in soil solutions was the highest with standard urea fertilization and the lowest in variants fertilized with slow-release urea for most of the months of the growing season. Higher concentrations of both nitrogen forms were noted at the fertilizer dose of 180 kg ha -1 . One-time fertilization, at both doses, resulted in higher nitrate concentrations in June and July, while dividing the dose into two rates resulted in higher nitrate concentrations between August and November. The highest potential for nitrate leaching during the growing season was in July. The tests confirmed that the miniaturized suction cups MacroRhizon are highly useful for routine monitoring the concentration of nitrate and ammonium ions in soil solutions under field conditions.

  18. A similar solution for an unsteady free convection flow past an impulsively started vertical plate with mass transfer and suction or injection

    International Nuclear Information System (INIS)

    Sattar, M.A.

    1990-12-01

    A similar solution for the flow past a vertical plate started impulsively in its own plane in a viscous incompressible fluid is presented on taking into account the effects of variable suction and/or injection and mass transfer. To solve the momentum, energy and concentration equations, a time dependent length scale is introduced, which leads to the driving parameters γ(=G r /R σ 2 ) and γ*(=G r */R σ 2 ), where G r and G r * are respectively the Grashof and modified Grashof numbers while R σ is the Reynolds number. The resulting locally similar momentum equation is then solved by the method of superposition. The effects of the parameters and that of suction/injection on the flow and on the wall shear-stress of the plate are shown graphically for different values of Schmidt number and transpiration parameter. (author). 24 refs, 11 figs

  19. Comparison in processing routes by copper mold casting injection and suction in the Cu46Zr42Al7Y5 vitreous alloy

    International Nuclear Information System (INIS)

    Batalha, W.; Aliaga, L.C.R.; Bolfarini, C.; Botta, W.J.; Kiminami, C.S.

    2014-01-01

    To expand the application of glassy metals, the development of processing routes and compositions that allow the production of parts with dimensions of millimeters or even centimeters, is very important. The present work aims the contribution to the technological development of processing routes for the production of Cu-based bulk metallic glasses. Wedge-shaped samples of Cu 46 Zr 42 Al 7 Y 5 (atom percent) chemical composition were processed using copper mold casting by suction and injection. Characterization was made combining scanning electron microscopy, x-ray diffraction and differential scanning calorimetry. The critical amorphous thickness obtained by those two different routes was carefully observed. The suction route allow obtaining the best results with critical amorphous thickness about 8 mm. This result was analyzed considering the different extrinsic parameters to the glass forming ability of the alloy. (author)

  20. BWR 200 % recirculation pump suction line break LOCA tests, RUNs 942 and 943 at ROSA-III without HPCS

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Tasaka, Kanji; Anoda, Yoshinari; Kumamaru, Hiroshige; Nakamura, Hideo; Yonomoto, Taisuke; Murata, Hideo; Koizumi, Yasuo

    1986-03-01

    This report presents the experimental results of RUNs 942 and 943 in ROSA-III program, which are 200 % recirculation pump suction line break LOCA tests with assumption of HPCS failure. The ROSA-III test facility simulates a BWR system with volume scale of 1/424 and has four half-length electrically heated fuel bundles, two active recirculation loops, ECCS's, and steam and feedwater systems. Effects of initial core void distribution and other fluid conditions on overall LOCA phenomena with special interest on transient core cooling phenomena were investigated by comparing the present test results with those of RUN 926, a 200 % suction line break test with standard initial fluid conditions. The initial core outlet quality was changed between 5 % and 43 %. As conclusions, (1) the initial lower core flow and higher void fraction affected significantly the core cooling conditions and resulted in earlier and higher PCT. (2) The lower plenum flashing temporarily contributed to cool down the core. (3) Flashing of remained hot water in the feedwater line affected slightly the pressure response and delayed the actuation of LPCI by 11 seconds. (4) The whole core was completely cooled down within 104 seconds after the LPCI actuation in these large break tests. (author)

  1. New fossil insect order Permopsocida elucidates major radiation and evolution of suction feeding in hemimetabolous insects (Hexapoda: Acercaria).

    Science.gov (United States)

    Huang, Di-Ying; Bechly, Günter; Nel, Patricia; Engel, Michael S; Prokop, Jakub; Azar, Dany; Cai, Chen-Yang; van de Kamp, Thomas; Staniczek, Arnold H; Garrouste, Romain; Krogmann, Lars; Dos Santos Rolo, Tomy; Baumbach, Tilo; Ohlhoff, Rainer; Shmakov, Alexey S; Bourgoin, Thierry; Nel, André

    2016-03-10

    With nearly 100,000 species, the Acercaria (lice, plant lices, thrips, bugs) including number of economically important species is one of the most successful insect lineages. However, its phylogeny and evolution of mouthparts among other issues remain debatable. Here new methods of preparation permitted the comprehensive anatomical description of insect inclusions from mid-Cretaceous Burmese amber in astonishing detail. These "missing links" fossils, attributed to a new order Permopsocida, provide crucial evidence for reconstructing the phylogenetic relationships in the Acercaria, supporting its monophyly, and questioning the position of Psocodea as sister group of holometabolans in the most recent phylogenomic study. Permopsocida resolves as sister group of Thripida + Hemiptera and represents an evolutionary link documenting the transition from chewing to piercing mouthparts in relation to suction feeding. Identification of gut contents as angiosperm pollen documents an ecological role of Permopsocida as early pollen feeders with relatively unspecialized mouthparts. This group existed for 185 million years, but has never been diverse and was superseded by new pollenivorous pollinators during the Cretaceous co-evolution of insects and flowers. The key innovation of suction feeding with piercing mouthparts is identified as main event that triggered the huge post-Carboniferous radiation of hemipterans, and facilitated the spreading of pathogenic vectors.

  2. Negative Suction Drain Through a Mini Periareolar Incision for the Treatment of Lactational Breast Abscess Shortens Hospital Stay and Increases Breastfeeding Rates.

    Science.gov (United States)

    Wei, Jinli; Zhang, Jiaxin; Fu, Deyuan

    2016-06-01

    Although breast abscess is a serious uncommon complication of mastitis with high morbidity rate, there is a lack of high-quality randomized trial to demonstrate the best treatments. We reported a novel way of applying negative suction drain through a mini periareolar incision. We retrospectively analyzed and compared the clinical characteristics of 62 patients with lactational breast abscess in our department from August 2012 to April 2015. Thirty-two patients went through traditional incision and drainage (Group A) and 30 patients were placed on negative suction drain through mini periareolar incision (Group B). There is no significant difference between the two groups in terms of age, white blood cell (WBC) count, size of the abscess cavity, and positive rate of Staphylococcus aureus (SA) or methicillin-resistant Staphylococcus aureus (MRSA). Patients in Group B had a shorter hospitalized stay (p = 0.003) and had a higher rate of continuation of breastfeeding (p breast abscess and maintaining breastfeeding.

  3. Observations on the flight pattern of some Phlaeothripidae (Thysanoptera species by using suction trap in Hungary

    Directory of Open Access Journals (Sweden)

    Orosz Szilvia

    2016-12-01

    Full Text Available In this study, the seasonal flight activity of the Phlaeothripidae (Thysanoptera species was studied by using suction trap, in South-East Hungary, in the years 2000 and 2004 from April to October. The flight period of two dominant species, namely Haplothrips angusticornis Priesner and Haplothrips aculeatus Fabricius (Thysanoptera: Phlaeothripidae, was observed in high number in Europe. Also, it was the first record of mass flight observation of H. angusticornis. In addition, the effect of meteorological factors, such as temperature, sunshine duration, relative humidity, air pressure, and their influences, were evaluated.

  4. Modification of Flow Structure Over a Van Model By Suction Flow Control to Reduce Aerodynamics Drag

    Directory of Open Access Journals (Sweden)

    Harinaldi Harinaldi

    2012-05-01

    Full Text Available Automobile aerodynamic studies are typically undertaken to improve safety and increase fuel efficiency as well as to  find new innovation in automobile technology to deal with the problem of energy crisis and global warming. Some car companies have the objective to develop control solutions that enable to reduce the aerodynamic drag of vehicle and  significant modification progress is still possible by reducing the mass, rolling friction or aerodynamic drag. Some flow  control method provides the possibility to modify the flow separation to reduce the development of the swirling structures around the vehicle. In this study, a family van is modeled with a modified form of Ahmed's body by changing the orientation of the flow from its original form (modified/reversed Ahmed body. This model is equipped with a suction on the rear side to comprehensively examine the pressure field modifications that occur. The investigation combines computational and experimental work. Computational approach used  a commercial software with standard k-epsilon flow turbulence model, and the objectives was  to determine the characteristics of the flow field and aerodynamic drag reduction that occurred in the test model. Experimental approach used load cell in order to validate the aerodynamic drag reduction obtained by computational approach. The results show that the application of a suction in the rear part of the van model give the effect of reducing the wake and the vortex formation. Futhermore, aerodynamic drag reduction close to 13.86% for the computational approach and 16.32% for the experimental have been obtained.

  5. Portable Filtered Air Suction System for Released Radioactive Gases Prevention under a Severe Accident of NPPs

    International Nuclear Information System (INIS)

    Gu, Beom W.; Choi, Su Y.; Rim, Chun T.

    2013-01-01

    In this paper, the portable filtered air suction system (PoFASS) for released radioactive gases prevention under a severe accident of NPP is proposed. This technology can prevent the release of the radioactive gases to the atmosphere and it can be more economical than FVCS because PoFASS can cover many NPPs with its high mobility. The conceptual design of PoFASS, which has the highest cost effectiveness and robustness to the environment condition such as wind velocity and precipitation, is suggested and the related previous research is introduced in this paper. The portable filtered air suction system (PoFASS) for released radioactive gases prevention can play a key role to mitigate the severe accident of NPP with its high cost effectiveness and robustness to the environment conditions. As further works, the detail design of PoFASS to fabricate a prototype for a demonstration will be proceeded. When released radioactive gases from the broken containment building in the severe accident of nuclear power plants (NPPs) such as the Chernobyl and Fukushima accidents occur, there are no ways to prevent the released radioactive gases spreading in the air. In order to solve this problem, several European NPPs have adopted the filtered vented containment system (FVCS), which can avoid the containment failure through a pressure relief capability to protect the containment building against overpressure. However, the installation cost of FVCS for a NPP is more than $10 million and this system has not been widely welcomed by NPP operating companies due to its high cost

  6. Remora fish suction pad attachment is enhanced by spinule friction.

    Science.gov (United States)

    Beckert, Michael; Flammang, Brooke E; Nadler, Jason H

    2015-11-01

    The remora fishes are capable of adhering to a wide variety of natural and artificial marine substrates using a dorsal suction pad. The pad is made of serial parallel pectinated lamellae, which are homologous to the dorsal fin elements of other fishes. Small tooth-like projections of mineralized tissue from the dorsal pad lamella, known as spinules, are thought to increase the remora's resistance to slippage and thereby enhance friction to maintain attachment to a moving host. In this work, the geometry of the spinules and host topology as determined by micro-computed tomography and confocal microscope data, respectively, are combined in a friction model to estimate the spinule contribution to shear resistance. Model results are validated with natural and artificially created spinules and compared with previous remora pull-off experiments. It was found that spinule geometry plays an essential role in friction enhancement, especially at short spatial wavelengths in the host surface, and that spinule tip geometry is not correlated with lamellar position. Furthermore, comparisons with pull-off experiments suggest that spinules are primarily responsible for friction enhancement on rough host topologies such as shark skin. © 2015. Published by The Company of Biologists Ltd.

  7. Effects of mass transfer on MHD flow of casson fluid with chemical reaction and suction

    Directory of Open Access Journals (Sweden)

    S. A. Shehzad

    2013-03-01

    Full Text Available Effect of mass transfer in the magnetohydrodynamic flow of a Casson fluid over a porous stretching sheet is addressed in the presence of a chemical reaction. A series solution for the resulting nonlinear flow is computed. The skin friction coefficient and local Sherwood number are analyzed through numerical values for various parameters of interest. The velocity and concentration fields are illustrated for several pertinent flow parameters. We observed that the Casson parameter and Hartman number have similar effects on the velocity in a qualitative sense. We further analyzed that the concentration profile decreases rapidly in comparison to the fluid velocity when we increased the values of the suction parameter.

  8. Instability and Transition of Flow at, and Near, an Attachment-line - Including Control by Surface Suction

    Science.gov (United States)

    Smith, A.

    1996-01-01

    Advances in aviation during and following the Second World War led to an enormous improvement in the performance of aircraft. The push for enhanced efficiency brought cruise speeds into the transonic range, where the associated drag rise due to the appearance of shock-waves became a limiting factor. Wing sweep was adopted to delay the onset of this drag rise, but with this development came several new and unforeseen problems. Preliminary theoretical work assumed that the boundary layer transition characteristics of a swept wing would be subject to the independence principle, so the chordwise transition position could be predicted from two-dimensional work Gas turbine development has now reached a point where additional increases in efficiency are both difficult and expensive to achieve. Consequently, aircraft manufacturers are looking elsewhere for ways to reduce Direct Operating Costs (DOC's) or increase military performance. The attention of industry is currently focusing on Hybrid Laminar Flow Control (HLFC) as a possible method of reducing DOC's for civil aircraft. Following this study and discussions with NASA Langley and Boeing a different series of questions have been addressed in the present work. There are five areas of interest: Relaminarisation of the attachment-line boundary layer when the value of R exceeds 600. The effects of large suction levels on transition in the attachment-line boundary layer (ie critical oversuction). The transition characteristics of a relaminarised attachment-line flow which encounters a non-porous surface. The effect of attachment-line suction on the spanwise propagation of gross disturbances emanating from the wing-fuselage junction. The attachment-line transition caused by surface blowing.

  9. Long-term clinical evaluation of a 800-nm long-pulsed diode laser with a large spot size and vacuum-assisted suction for hair removal.

    Science.gov (United States)

    Ibrahimi, Omar A; Kilmer, Suzanne L

    2012-06-01

    The long-pulsed diode (800-810-nm) laser is one of the most commonly used and effective lasers for hair removal. Limitations of currently available devices include a small treatment spot size, treatment-associated pain, and the need for skin cooling. To evaluate the long-term hair reduction capabilities of a long-pulsed diode laser with a large spot size and vacuum assisted suction. Thirty-five subjects were enrolled in a prospective, self-controlled, single-center study of axillary hair removal. The study consisted of three treatments using a long-pulsed diode laser with a large spot size and vacuum-assisted suction at 4- to 6-week intervals with follow-up visits 6 and 15 months after the last treatment. Hair clearance was quantified using macro hair-count photographs taken at baseline and at 6- and 15-month follow-up visits. Changes in hair thickness and color, levels of treatment-associated pain, and adverse events were additional study endpoints. There was statistically significant hair clearance at the 6 (54%) and 15-month (42%) follow-up visits. Remaining hairs were thinner and lighter at the 15-month follow-up visit, and the majority of subjects reported feeling up to mild to moderate pain during treatment without the use of pretreatment anesthesia or skin cooling. A long-pulsed diode laser with a large spot size and vacuum-assisted suction is safe and effective for long-term hair removal. This is the largest prospective study to evaluate long-term hair removal and the first to quantify decreases in hair thickness and darkness with treatment. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  10. A biorobotic model of the suction-feeding system in largemouth bass: the roles of motor program speed and hyoid kinematics

    OpenAIRE

    Kenaley, Christopher P.; Lauder, George V.

    2016-01-01

    The vast majority of ray-finned fishes capture prey through suction feeding. The basis of this behavior is the generation of subambient pressure through rapid expansion of a highly kinetic skull. Over the last four decades, results from in vivo experiments have elucidated the general relationships between morphological parameters and subambient pressure generation. Until now, however, researchers have been unable to tease apart the discrete contributions of, and complex relationships among, t...

  11. Effect of boron addition on the magnetic properties of the Fe-Nd-Al alloys prepared by suction casting

    International Nuclear Information System (INIS)

    Bai, Q.; Xu, H.; Tan, X.H.; Zhang, S.Y.

    2007-01-01

    The microstructure and magnetic properties of the Fe-Nd-Al alloys prepared by suction casting with boron addition have been investigated. The increasing boron content in the Fe-Nd-Al alloys significantly increases the intrinsic coercivity ( i H c ) and decreases the proportion of the amorphous phase. The magnetization at the maximum applied field (σ ' s ) of the Fe-Nd-Al-B alloys decreases, while the coercivity increases markedly after annealing. The high intrinsic coercivity is due to the presence of the Nd 2 Fe 14 B phase

  12. In patients with extensive subcutaneous emphysema, which technique achieves maximal clinical resolution: infraclavicular incisions, subcutaneous drain insertion or suction on in situ chest drain?

    Science.gov (United States)

    Johnson, Charles H N; Lang, Sommer A; Bilal, Haris; Rammohan, Kandadai S

    2014-06-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: 'In patients with extensive subcutaneous emphysema, which technique achieves maximal clinical resolution: infraclavicular incisions, subcutaneous drain insertion or suction on in situ chest drain?'. Altogether more than 200 papers were found using the reported search, of which 14 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Subcutaneous emphysema is usually a benign, self-limiting condition only requiring conservative management. Interventions are useful in the context of severe patient discomfort, respiratory distress or persistent air leak. In the absence of any comparative study, it is not possible to choose definitively between infraclavicular incisions, drain insertion and increasing suction on an in situ drain as the best method for managing severe subcutaneous emphysema. All the three techniques described have been shown to provide effective relief. Increasing suction on a chest tube already in situ provided rapid relief in patients developing SE following pulmonary resection. A retrospective study showed resolution in 66%, increasing to 98% in those who underwent video-assisted thoracic surgery with identification and closure of the leak. Insertion of a drain into the subcutaneous tissue also provided rapid sustained relief. Several studies aided drainage by using regular compressive massage. Infraclavicular incisions were also shown to provide rapid relief, but were noted to be more invasive and carried the potential for cosmetic defect. No major complications were illustrated. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Laboratory Setup for Vertically Loaded Suction Caisson Foundation in Sand and Validation of Responses

    DEFF Research Database (Denmark)

    Manzotti, E.; Vaitkunaite, Evelina; Ibsen, Lars Bo

    during the last years and, following this trend, design choice will turn into foundation composed of three or four suction bucket foundations, called respectively tripod and tetrapod. Overturning moment in tripod and tetrapod is carried by vertical loading; therefore vertical pull-out capacity is tested......, in both static and cyclic case of loading. Testing rig and equipment are presented together with procedures. Tests results are presented in order to verify the output of tests. CPT-based methods and beta-methods to evaluate installation and pull-out resistance are then presented and implemented in Matlab...... in order to validate responses. It is demonstrated that kf parameter of CPT-based methods is dependent on the overburden pressure applied. Parameters of beta methods are analyzed and defined. Satisfying results are obtained with methods that are considering a linear increase or decrease with the depth...

  14. Suckermouth armored catfish resolve the paradox of simultaneous respiration and suction attachment: a kinematic study of Pterygoplichthys disjunctivus.

    Science.gov (United States)

    Geerinckx, Tom; Herrel, Anthony; Adriaens, Dominique

    2011-03-01

    Suckermouth armored catfishes (Loricariidae) use their suckermouth for inspiration, feeding, and attachment to substrates. The sucker consists of a pre-valvular cavity, formed by a modified lip disc, and is separated from the larger post-valvular buccal cavity by a muscular oral valve. The combination of respiration and suction attachment seems paradoxal, as a properly functioning suction device would need a sucker without leakage (yet inspiration must occur via the sucker), and continuous subambient pressure in the sucker cavity (even during expiratory mouth floor elevation). In the loricariid Pterygoplichthys disjunctivus, the anatomy of the suckermouth structures was examined, and a kinematic analysis was performed to acquire insights into how respiration and attachment are combined. High-speed external and X-ray recordings show that suckermouth attachment influences respiratory parameters such as decreasing excursion amplitudes of mouth floor elements, and the way water enters the mouth via furrows in the lip disc. Respiration, however, continues during attachment and is not blocked. Our data show that the muscular oral valve actively separates the post-valvular buccal cavity from the pre-valvular sucker cavity. Volume changes of this pre-valvular cavity are opposite to those of the post-valvular cavity and assure sucker function even during expiration. These volume changes are caused by movements of the lower lip, the lower jaws, and the oral valve. The lateral inflow furrow openings, controlled by the maxillary barbels, can occur unilaterally. Morphological and kinematic data also show that the opercle is anatomically and functionally decoupled from the gill opening. Copyright © 2010 Wiley-Liss, Inc., A Wiley Company.

  15. Thermodynamic analysis of a refrigeration cycle using regenerative heat exchanger - suction/liquid line

    Energy Technology Data Exchange (ETDEWEB)

    Tebchirani, Tarik Linhares; Matos, Rudmar Serafim [Pos graduate Programme in Mechanical Engineering (PGMEC), Universidade Federal do Parana, Curitiba, PR (Brazil)], e-mails: tarik@utfpr.edu.br, rudmar@demec.ufpr.br

    2010-07-01

    This paper presents results from thermodynamic comparison of a conventional compression cycle and a steam cycle that uses a heat exchanger countercurrent (liquid line/suction line) in an air conditioning system split. The main objective is to study the relationship between the COP and the mass variation of refrigerant to the effectiveness of the heat exchanger. The papers presented in the literature discuss the matter in a theoretical way, are summarized in tables of rare loss statements without specification of methods. The methodology of work is based on testing of an air conditioner operating conventionally and also with the heat exchanger for the determination of values and parameters of interest. The tests were performed in a thermal chamber with temperature controlled and equipped with a data acquisition system for reading and storage results. The refrigerant was R22. Besides making possible an assessment of the feasibility of cost-benefit thermodynamics, it is suggested a different method for installing the equipment type split. (author)

  16. Experiment data of 200% recirculation pump discharge line break integral test run 961 with HPCS failure at ROSA-III and comparison with results of suction line break tests

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Tasaka, Kanji; Nakamura, Hideo; Anoda, Yoshinari; Kumamaru, Hiroshige; Murata, Hideo; Yonomoto, Taisuke; Shiba, Masayoshi

    1984-03-01

    This report presents the experimental data of RUN 961, a 200% double-ended break test at the recirculation pump discharge line in the ROSA-III test facility. The ROSA-III test facility is a volumetrically scaled (1/424) system of the BWR/6. The facility has the electrically heated core, the break simulator and the scaled ECCS (Emergency Core Cooling System). The MSIV (Main Steam Isolation Valve) closure and the ECCS actuation were tripped by the liquid level in the upper downcomer. The PCT (Peak Cladding Temperature) was 894 K, which was 107 K higher than a 200% pump suction line break test (RUN 926) due to the smaller depressurization rate. The effect of break location on transient LOCA phenomena was clarified by comparing the discharge and suction break tests. The whole core was quenched 71 s after LPCI actuation and the effectiveness of ECCS has been confirmed. (author)

  17. High negative pressure subcutaneous suction drain for managing debilitating subcutaneous emphysema secondary to tube thoracostomy for an iatrogenic post computed tomography guided transthoracic needle biopsy pneumothorax: Case report and review of literature

    Directory of Open Access Journals (Sweden)

    Zeeshan Ahmed

    2016-01-01

    Conclusion: Debilitating subcutaneous emphysema which causes distress, anxiety, palpebral closure, dyspnoea or dysphagia requires intervention. High negative pressure subcutaneous suction drain provides immediate and sustained relief in extensive and debilitating SE.

  18. Efectos de la contención en hipoxia percutánea posterior a la aspiración endotraqueal en neonatos Effects of containment on percutaneous hipoxia after endotracheal suctioning in neonates

    Directory of Open Access Journals (Sweden)

    Bertha Cecilia Salazar González

    2007-03-01

    Full Text Available Objetivo: Verificar la efectividad de la contención en el tiempo de recuperación de la hipoxia percutánea de neonatos prematuros con Síndrome de Dificultad Respiratoria, posterior a la aspiración con y sin bolsa de oxígeno pre-aspiración. La contención es una técnica que limita los movimientos del neonato simulando el ambiente uterino y se propone como ayuda para inducir la relajación en los prematuros. Material y métodos: Se diseñó un estudio de mediciones repetidas con un grupo; cada neonato fue su propio control. Se estudiaron 30 neonatos nacidos entre la semana 26 y 36 de gestación en una Unidad de Cuidados Intensivos Neonatal de un Hospital de Seguridad Social de Monterrey, de agosto a diciembre de 2002. Se observaron cuatro procedimientos de aspiración endotraqueal: dos sin contención y dos con contención. Resultados: El peso al nacer de los neonatos osciló entre .790 y 3.275 Kg. De acuerdo con el expediente, 25 de ellos (83.30% presentaron Síndrome de Dificultad Respiratoria moderado. La prueba de análisis de varianza, F(3,87= 7.77, p Objective: The purpose was to verify the effectiveness of containment using pre-suction oxygen bag versus non pre-suction oxygen bag on recovery time of percutaneous hipoxia values after endotracheal suctioning of premature infants with respiratory distress syndrome. Containment is proposed as an aid to induce relaxation in premature babies; it is a technique that limits a neonate’s movements resembling the uterus environment. Material and methods: A crossover design with one group was used, each neonate serve as its own control. This study was conducted in 30 neonates who had been born between 26 and 36 weeks gestational age, in a Neonatal Intensive Care Unit of a Social Security’s Hospital in Monterrey. Each neonate was observed during four suction procedures: two without containment and two with containment. Results: The neonate’s weight ranged from .790 to 3.275Kg., according to

  19. Is the transposition of the nipple-areolar complex necessary in Simon grade 2b gynecomastia operations using suction-assisted liposuction?

    Science.gov (United States)

    Özalp, Burhan; Berköz, Ömer; Aydınol, Mustafa

    2018-02-01

    The aim of this study was to assess the efficacy of suction-assisted liposuction (SAL) in Simon grade 2b gynecomastia and its effect on sternal notch to nipple areola (SNN) distance. A retrospective analysis was performed on 21 patients with grade 2b gynecomastia who underwent SAL. Preoperative and postoperative SNN distances of the patients were measured, the results were analysed using a Mann-Whitney U test and a p-value gynecomastia and shortens the SNN distance by 1 cm, but further clinical studies are required to support this conclusion.

  20. Treatment of cellulite with a bipolar radiofrequency, infrared heat, and pulsatile suction device: a pilot study.

    Science.gov (United States)

    Wanitphakdeedecha, Rungsima; Manuskiatti, Woraphong

    2006-12-01

    Very few therapeutic options have proven effective in the treatment of cellulite. To evaluate the effectiveness and adverse effects of a bipolar radiofrequency (RF), infrared (IR) heat and pulsatile suction device for the treatment of cellulite. Twelve subjects were treated with the RF-light-based device. All subjects were treated twice weekly for a total number of eight to nine treatments. Subjects were evaluated using standardized photographs, and measurements of body weight and circumference of treatment sites at baseline, immediately after the last treatment, and four weeks and one year after the last treatment. Clinical improvement scores of comparable photographs using a quartile grading scale (0 = 75% improvement) were judged independently by two non-treating dermatologists after the series of treatment. The average body weights at baseline, immediately after the last treatment, and four weeks and one year after the complete treatment were 56.30, 56.05, 56.23, and 56.53 kg, respectively. The average circumferential reductions of the abdomen and thigh at the last treatment visit were 5.17 +/- 1.04 cm (6.32%+/- 1.82%) and 3.50 +/- 2.16 cm (6.23 +/- 3.58%), respectively. At four weeks after the last treatment, the average circumferential reductions of the abdomen and thigh were sustained at 3.17 +/- 2.75 cm (4.04%+/- 3.69%) and 3.50 +/- 2.04 cm (6.26%+/- 3.52%), respectively. At one year follow-up visit, the average circumferential reductions of the abdomen and thigh were maintained at 3.83 +/- 0.76 cm (4.64%+/- 1.15%) and 3.13 +/- 3.54 (5.50%+/- 6.12%), respectively. Average clinical improvement scores of the abdomen and thigh after the series of treatments were 0.75 (corresponding to approximately 25% improvement), and 1.75 (corresponding to approximately 50% improvement), respectively. A bipolar RF, IR heat and pulsatile suction device provides a beneficial effect on reduction of abdomen and thigh circumference, and smoothening of the cellulite.

  1. Vortex generation and wave-vortex interaction over a concave plate with roughness and suction

    Science.gov (United States)

    Bertolotti, Fabio

    1993-01-01

    The generation and amplification of vortices by surface homogeneities, both in the form of surface waviness and of wall-normal velocity, is investigated using the nonlinear parabolic stability equations. Transients and issues of algebraic growth are avoided through the use of a similarity solution as initial condition for the vortex. In the absence of curvature, the vortex decays as the square root of 1/x when flowing over streamwise aligned riblets of constant height, and grows as the square root of x when flowing over a corresponding streamwise aligned variation of blowing/suction transpiration velocity. However, in the presence of wall inhomogeneities having both streamwise and spanwise periodicity, the growth of the vortex can be much larger. In the presence of curvature, the vortex develops into a Gortler vortex. The 'direct' and 'indirect' interaction mechanisms possible in wave-vortex interaction are presented. The 'direct' interaction does not lead to strong resonance with the flow conditions investigated. The 'indirect' interaction leads to K-type transition.

  2. Effect of Reynolds Number and Periodic Unsteady Wake Flow Condition on Boundary Layer Development, Separation, and Intermittency Behavior Along the Suction Surface of a Low Pressure Turbine Blade

    Science.gov (United States)

    Schobeiri, M. T.; Ozturk, B.; Ashpis, David E.

    2007-01-01

    The paper experimentally studies the effects of periodic unsteady wake flow and different Reynolds numbers on boundary layer development, separation and re-attachment along the suction surface of a low pressure turbine blade. The experimental investigations were performed on a large scale, subsonic unsteady turbine cascade research facility at Turbomachinery Performance and Flow Research Laboratory (TPFL) of Texas A&M University. The experiments were carried out at Reynolds numbers of 110,000 and 150,000 (based on suction surface length and exit velocity). One steady and two different unsteady inlet flow conditions with the corresponding passing frequencies, wake velocities, and turbulence intensities were investigated. The reduced frequencies chosen cover the operating range of LP turbines. In addition to the unsteady boundary layer measurements, surface pressure measurements were performed. The inception, onset, and the extent of the separation bubble information collected from the pressure measurements were compared with the hot wire measurements. The results presented in ensemble-averaged, and the contour plot forms help to understand the physics of the separation phenomenon under periodic unsteady wake flow and different Reynolds number. It was found that the suction surface displayed a strong separation bubble for these three different reduced frequencies. For each condition, the locations defining the separation bubble were determined carefully analyzing and examining the pressure and mean velocity profile data. The location of the boundary layer separation was dependent of the Reynolds number. It is observed that starting point of the separation bubble and the re-attachment point move further downstream by increasing Reynolds number from 110,000 to 150,000. Also, the size of the separation bubble is smaller when compared to that for Re=110,000.

  3. A Giant Chelonioid Turtle from the Late Cretaceous of Morocco with a Suction Feeding Apparatus Unique among Tetrapods

    Science.gov (United States)

    Bardet, Nathalie; Jalil, Nour-Eddine; de Lapparent de Broin, France; Germain, Damien; Lambert, Olivier; Amaghzaz, Mbarek

    2013-01-01

    Background Secondary adaptation to aquatic life occurred independently in several amniote lineages, including reptiles during the Mesozoic and mammals during the Cenozoic. These evolutionary shifts to aquatic environments imply major morphological modifications, especially of the feeding apparatus. Mesozoic (250–65 Myr) marine reptiles, such as ichthyosaurs, plesiosaurs, mosasaurid squamates, crocodiles, and turtles, exhibit a wide range of adaptations to aquatic feeding and a broad overlap of their tooth morphospaces with those of Cenozoic marine mammals. However, despite these multiple feeding behavior convergences, suction feeding, though being a common feeding strategy in aquatic vertebrates and in marine mammals in particular, has been extremely rarely reported for Mesozoic marine reptiles. Principal Findings A relative of fossil protostegid and dermochelyoid sea turtles, Ocepechelon bouyai gen. et sp. nov. is a new giant chelonioid from the Late Maastrichtian (67 Myr) of Morocco exhibiting remarkable adaptations to marine life (among others, very dorsally and posteriorly located nostrils). The 70-cm-long skull of Ocepechelon not only makes it one of the largest marine turtles ever described, but also deviates significantly from typical turtle cranial morphology. It shares unique convergences with both syngnathid fishes (unique long tubular bony snout ending in a rounded and anteriorly directed mouth) and beaked whales (large size and elongated edentulous jaws). This striking anatomy suggests extreme adaptation for suction feeding unmatched among known turtles. Conclusion/Significance The feeding apparatus of Ocepechelon, a bony pipette-like snout, is unique among tetrapods. This new taxon exemplifies the successful systematic and ecological diversification of chelonioid turtles during the Late Cretaceous. This new evidence for a unique trophic specialization in turtles, along with the abundant marine vertebrate faunas associated to Ocepechelon in the Late

  4. A giant chelonioid turtle from the late Cretaceous of Morocco with a suction feeding apparatus unique among tetrapods.

    Science.gov (United States)

    Bardet, Nathalie; Jalil, Nour-Eddine; de Lapparent de Broin, France; Germain, Damien; Lambert, Olivier; Amaghzaz, Mbarek

    2013-01-01

    Secondary adaptation to aquatic life occurred independently in several amniote lineages, including reptiles during the Mesozoic and mammals during the Cenozoic. These evolutionary shifts to aquatic environments imply major morphological modifications, especially of the feeding apparatus. Mesozoic (250-65 Myr) marine reptiles, such as ichthyosaurs, plesiosaurs, mosasaurid squamates, crocodiles, and turtles, exhibit a wide range of adaptations to aquatic feeding and a broad overlap of their tooth morphospaces with those of Cenozoic marine mammals. However, despite these multiple feeding behavior convergences, suction feeding, though being a common feeding strategy in aquatic vertebrates and in marine mammals in particular, has been extremely rarely reported for Mesozoic marine reptiles. A relative of fossil protostegid and dermochelyoid sea turtles, Ocepechelon bouyai gen. et sp. nov. is a new giant chelonioid from the Late Maastrichtian (67 Myr) of Morocco exhibiting remarkable adaptations to marine life (among others, very dorsally and posteriorly located nostrils). The 70-cm-long skull of Ocepechelon not only makes it one of the largest marine turtles ever described, but also deviates significantly from typical turtle cranial morphology. It shares unique convergences with both syngnathid fishes (unique long tubular bony snout ending in a rounded and anteriorly directed mouth) and beaked whales (large size and elongated edentulous jaws). This striking anatomy suggests extreme adaptation for suction feeding unmatched among known turtles. The feeding apparatus of Ocepechelon, a bony pipette-like snout, is unique among tetrapods. This new taxon exemplifies the successful systematic and ecological diversification of chelonioid turtles during the Late Cretaceous. This new evidence for a unique trophic specialization in turtles, along with the abundant marine vertebrate faunas associated to Ocepechelon in the Late Maastrichtian phosphatic beds of Morocco, further

  5. A giant chelonioid turtle from the late Cretaceous of Morocco with a suction feeding apparatus unique among tetrapods.

    Directory of Open Access Journals (Sweden)

    Nathalie Bardet

    Full Text Available BACKGROUND: Secondary adaptation to aquatic life occurred independently in several amniote lineages, including reptiles during the Mesozoic and mammals during the Cenozoic. These evolutionary shifts to aquatic environments imply major morphological modifications, especially of the feeding apparatus. Mesozoic (250-65 Myr marine reptiles, such as ichthyosaurs, plesiosaurs, mosasaurid squamates, crocodiles, and turtles, exhibit a wide range of adaptations to aquatic feeding and a broad overlap of their tooth morphospaces with those of Cenozoic marine mammals. However, despite these multiple feeding behavior convergences, suction feeding, though being a common feeding strategy in aquatic vertebrates and in marine mammals in particular, has been extremely rarely reported for Mesozoic marine reptiles. PRINCIPAL FINDINGS: A relative of fossil protostegid and dermochelyoid sea turtles, Ocepechelon bouyai gen. et sp. nov. is a new giant chelonioid from the Late Maastrichtian (67 Myr of Morocco exhibiting remarkable adaptations to marine life (among others, very dorsally and posteriorly located nostrils. The 70-cm-long skull of Ocepechelon not only makes it one of the largest marine turtles ever described, but also deviates significantly from typical turtle cranial morphology. It shares unique convergences with both syngnathid fishes (unique long tubular bony snout ending in a rounded and anteriorly directed mouth and beaked whales (large size and elongated edentulous jaws. This striking anatomy suggests extreme adaptation for suction feeding unmatched among known turtles. CONCLUSION/SIGNIFICANCE: The feeding apparatus of Ocepechelon, a bony pipette-like snout, is unique among tetrapods. This new taxon exemplifies the successful systematic and ecological diversification of chelonioid turtles during the Late Cretaceous. This new evidence for a unique trophic specialization in turtles, along with the abundant marine vertebrate faunas associated to

  6. [Study and development of a new automatic suction system (SS) of intratracheal sputum in order to improve QOL of many patients with tracheostomy mechanical ventilation (TMV) and their family members by this new autonomic SS].

    Science.gov (United States)

    Hokezu, Youichi; Yamamoto, Makoto; Tokunaga, Syuichi; Niikura, Makoto; Nagamatsu, Keiji; Kira, Jun-ichi; Fukunaga, Toshihide; Shima, Kouji; Kikuchi, Seiji; Kimura, Itaru; Kondo, Kiyohiko; Mori, Teruhiko; Goto, Katumasa; Takigami, Shigeru; Shioya, Keiichi; Uehara, Minako

    2009-11-01

    In Japan, many patients equipped with TMV are under medical treatment at home after 1990. These patients can't put out sputa in trachea, so that these patient's family members must suck these patient's intratracheal sputa all days. Mr Yamamoto and Mr Tokunaga, main researchers of this study, began the study on the automatic SS of itratracheal sputa from 1999. In first stage, They developed the intermittent SS in detaining the suction tube within tracheal cannula, monitering the intratracheal pressure, but this system takes the ventilation away from the patient. Hypoventilation caused by this SS may cause the serious accident in patient. Therefore, we remodel the SS from intermittent SS to rollerpomp-type SS continuing to suck the itratracheal sputa with low volume from 2004, and thereafter we made up the SS of piston pomp type-SS finally at 2007. We developed the tracheal cannula with double suction holes of inner and lower hole in the lower part of its cannula together with the suction machine. We think that the practical use of this automatic SS will bring these patients with TMV and their family members great benefits. We desire that the practical use of this SS will be realized as soon as possible.

  7. Caracterización de la succión en el lactante según la rehabilitación neuro-oclusal Characterization of newborn suction according the neuro-occlusal rehabilitation

    Directory of Open Access Journals (Sweden)

    Dania Santos Prieto

    2010-09-01

    Full Text Available En el primer mes de vida del niño, la succión juega un papel fundamental para fijar las praxias bucales básicas, que constituyen el patrón funcional de base para el desarrollo y maduración de las funciones del sistema estomatognático del niño mayor y del adulto. Se realizó un estudio descriptivo transversal con aplicación de métodos cuantitativos y recogida de datos cualitativos, para caracterizar el desarrollo de la succión del recién nacido, a través de la rehabilitación neuro-oclusal. El universo de esta investigación estuvo constituido por 56 niños pertenecientes al área de salud de la Policlínica "Santa Clara", en el periodo comprendido de septiembre a noviembre de 2008. Para la recogida de la información acerca de las variables objeto de estudio, se utilizó como instrumento la ficha de observación, que describió el momento de la succión de la leche materna. En el análisis del estudio, para ganar claridad en los resultados, se utilizaron análisis descriptivos y comparativos. La succión del lactante presentó dificultades asociadas a varios factores. Uno fue la posición inadecuada, caracterizada por la falta de alineación y la separación del cuerpo del bebé de la madre. Otro lo constituyó la anatomía de la mama, tal como los pechos ingurgitados y los pezones planos e invertidos. También hubo dificultades relacionadas con el acto mismo de succión, tales como la boca no muy abierta, más areola por debajo de la boca del bebé, el labio inferior invertido, el mentón sin tocar el pecho, y el chasqueo al deglutir. En los recién nacidos tomados como muestra de estudio predominó la succión ineficaz.During the first year of life of infant the suction plays a main role to fix the practical buccal praxis that are the basis functional pattern for development and maturation of Stomatognatic System functions of older child and of adult. A cross-sectional and descriptive study was conducted to apply the quantitative

  8. Comparing the role of subcision suction method with and without the injection of platelet-rich plasma in the treatment of depressed scars

    Directory of Open Access Journals (Sweden)

    Nouran Abd El-Aziz Abou Khedr

    2017-02-01

    Full Text Available Among wound-healing modalities, platelet-rich plasma (PRP has been used for wound healing, through the release of multiple growth factors. The platelets mediate wound healing by initiating the clotting pathway and the subsequent matrix remodelisation. The aim of the work was to study the role of injection of platelet-rich plasma in the treatment of scars. This study was conducted on thirty patients who were divided into two groups (A and B. Each group included fifteen patients. The two groups were randomly distributed by using individual sealed envelopes. Group A was subjected to subcision of their acne scars using Nokor needle, followed by suction. Group B patients were subjected to the same treatment but followed by an injection of platelet-rich plasma once per month over three months. In Group A, 6 patients (40% showed moderate improvement, 5 patients (33.3% showed slight improvement and 4 patients (26.7% showed significant improvement. In Group B, 7 patients (46.7% showed moderate improvement, 5 patients (33.3% showed marked improvement and 3 patients (20% showed significant improvement. There was a statistically significant difference on the independent observer’s after-treatment assessment between the groups (P=0.014. In conclusion, subcision suction leads to a persistent improvement of acne scars in a short time, and the coupling with injection of PRP is the most effective in the treatment of depressed facial scars.

  9. Rapid solidification of Ni50Nb28Zr22 glass former alloy through suction-casting

    International Nuclear Information System (INIS)

    Miyamoto, M.I.; Santos, F.S.; Bolfarini, C.; Botta Filho, W.J.; Kiminami, C.S.

    2010-01-01

    To select new alloys with high glass forming ability (GFA) to present amorphous structure in millimeter scale, several semi-empirical models have been developed. In the present work, a new alloy, Ni 50 Nb 28 Zr 22 d, was designed based on the combination of topological instability lambda (A) criterion and electronegativity difference (Δe). The alloy was rapidly solidified in a bulk wedge sample by cooper mold suction casting in order to investigate its amorphization. The sample was characterized by the combination of scanning electron microscopy (MEV), X-ray diffraction (XRD) and differential scanning calorimeter (DSC). For the minimum thickness of 200 μm analyzed, it was found that the alloy did not show a totally amorphous structure. Factor such as low cooling rate, existence of oxides on the surface of the elements and presence of oxygen in the atmosphere of equipment did not allowed the achievement of higher amorphous thickness. (author)

  10. Composite Behavior of Insulated Concrete Sandwich Wall Panels Subjected to Wind Pressure and Suction

    Directory of Open Access Journals (Sweden)

    Insub Choi

    2015-03-01

    Full Text Available A full-scale experimental test was conducted to analyze the composite behavior of insulated concrete sandwich wall panels (ICSWPs subjected to wind pressure and suction. The experimental program was composed of three groups of ICSWP specimens, each with a different type of insulation and number of glass-fiber-reinforced polymer (GFRP shear grids. The degree of composite action of each specimen was analyzed according to the load direction, type of the insulation, and number of GFRP shear grids by comparing the theoretical and experimental values. The failure modes of the ICSWPs were compared to investigate the effect of bonds according to the load direction and type of insulation. Bonds based on insulation absorptiveness were effective to result in the composite behavior of ICSWP under positive loading tests only, while bonds based on insulation surface roughness were effective under both positive and negative loading tests. Therefore, the composite behavior based on surface roughness can be applied to the calculation of the design strength of ICSWPs with continuous GFRP shear connectors.

  11. Chemical reaction effect on an unsteady MHD free convection flow past a vertical porous plate in the presence of suction or injection

    Directory of Open Access Journals (Sweden)

    Shivaiah S.

    2012-01-01

    Full Text Available The objective of this paper is to analyze the effect of chemical reaction on unsteady magneto hydrodynamic free convective fluid flow past a vertical porous plate in the presence of suction or injection. The governing equations of the flow field are solved numerically by a finite element method. The effects of the various parameters on the velocity, temperature and concentration profiles are presented graphically and values of skin-friction coefficient, Nusselt number and Sherwood number for various values of physical parameters are presented through tables.

  12. FIST/6IB1, BWR/6 System Responses to Intermediate Break in Recirculation Suction Line LINE

    International Nuclear Information System (INIS)

    1993-01-01

    1 - Description of test facility: BWR/6-218 standard plant. A full size bundle with electrically heated rods is used to simulate the reactor core. A scaling ratio of 1/624 is applied in the design of the system components. Key features of the FIST facility include: (1) Full height test vessel and internals; (2) correctly scaled fluid volume distribution; (3) simulation of ECCS, S/RV, and ADS; (4) level trip capability; (5) heated feedwater supply system, which provides the capability for steady state operation. 2 - Description of test: Test 6IB1 investigates system responses to an intermediate break in the recirculation suction line. BWR system licensing evaluations for various size recirculation break LOCA's indicates that a break size of about 0.2 sq.ft., without LPCS operation, is the highest PCT case for the intermediate break LOCA. Test 6IB1 simulates this event

  13. The experience of caesarean scar pregnancy treated with suction curettage under hysterocopy guidance%宫腔镜监测下清宫术治疗剖宫产瘢痕妊娠

    Institute of Scientific and Technical Information of China (English)

    曹毅; 肖琳; 唐良萏

    2011-01-01

    Objective:To describe our experience on the treatment of caesarean sear pregnancy with suction and curettage under hysterascopy guidance. Methods: Seven patients diagnosed as caesarean section sear pregnancy treated in our department underwent suction curettage under hystcroseopy between 2007 and 2009. Medical records and hysterecopy pictures of seven cases were collected and reviewed. Results: Four of them had complete suction cnrretage and uneventful outcome. Two had incomplete evacuation and small amount of hemorrhage. After Systemic MTX treatment, serum β- hCG decreased and pregnancy remnants disappeared progressively. One had heavy hemorrhage. Laparotomy was performed and the lesion was excised. Analysis of all these women's hysterocopy characteristics revealed that four successfully treated women had intrauterine gestational sacs. One who had experienced heavy hemorrhage and laparotomy were with deep sac implantation. Conclusions:Suction curettage is a feasible conservative procedure for cases that had intrauterine gestational sacs. Hysteroscopy are useful for screening suitable cases and guiding the procedure.%目的:探讨清宫术治疗剖宫产瘢痕妊娠的指征。方法:对2007—2009年在我院诊断剖宫产瘢痕妊娠、给予宫腔镜辅助清宫术治疗的患者7例进行回顾性分析,评价临床资料、B超检查、宫腔镜表现与治疗效果的关系。结果:4例患者用清宫术治愈,出血不多:2例清宫不全、补充药物治疗(MTX)后治愈;1例清宫术中出血多、急诊开腹手术行病灶切除术。成功治疗的患者宫腔镜检查表现为孕囊凸向腔内,而出血多、治疗失败的患者孕囊植入深。结论:对妊娠物凸向宫腔内的剖宫产瘢痕妊娠,清宫术是有效、简便的治疗方法,宫腔镜有利于筛选合适病例。

  14. Influence of fluid viscosity on vortex cavitation at a suction pipe inlet

    International Nuclear Information System (INIS)

    Ezure, Toshiki; Ito, Kei; Kamide, Hideki; Kameyama, Yuri; Kunugi, Tomoaki

    2016-01-01

    Cavitation is a highly important issue in various fluid machineries. In the design of an advanced loop-type sodium-cooled fast reactor in Japan, vortex cavitation is also a significant issue for the integrity of the reactor structure. Thus, an evaluation method for vortex cavitation is required. In this study, vortex cavitation at a single suction pipe inlet was studied under several different viscosity conditions including its transient behavior. The intermittent occurrence behaviors of vortex cavitation were grasped by visualization measurements. The experimental results showed that the influence of the kinematic viscosity was obvious under a high kinematic viscosity. However, the influence became smaller with decreasing kinematic viscosity. From these results, the non-dimensional circulation, which was defined as the ratio of the local circulation to the kinematic viscosity, was deduced as an evaluation parameter to estimate the influence of the kinematic viscosity. Cavitation factors at transition points from continuous occurrence to intermittent occurrences were also evaluated as representative points where vortex cavitation occurs. Then, the occurrences of vortex cavitation were expressed as a relation between the cavitation factor at transition points and the non-dimensional circulation. As a result, it was clarified that the cavitation factor at transition points increased linearly in relatively small non-dimensional circulation, while it was nearly constant in relatively large non-dimensional circulation. (author)

  15. A biorobotic model of the suction-feeding system in largemouth bass: the roles of motor program speed and hyoid kinematics.

    Science.gov (United States)

    Kenaley, Christopher P; Lauder, George V

    2016-07-01

    The vast majority of ray-finned fishes capture prey through suction feeding. The basis of this behavior is the generation of subambient pressure through rapid expansion of a highly kinetic skull. Over the last four decades, results from in vivo experiments have elucidated the general relationships between morphological parameters and subambient pressure generation. Until now, however, researchers have been unable to tease apart the discrete contributions of, and complex relationships among, the musculoskeletal elements that support buccal expansion. Fortunately, over the last decade, biorobotic models have gained a foothold in comparative research and show great promise in addressing long-standing questions in vertebrate biomechanics. In this paper, we present BassBot, a biorobotic model of the head of the largemouth bass (Micropterus salmoides). BassBot incorporates a 3D acrylic plastic armature of the neurocranium, maxillary apparatus, lower jaw, hyoid, suspensorium and opercular apparatus. Programming of linear motors permits precise reproduction of live kinematic behaviors including hyoid depression and rotation, premaxillary protrusion, and lateral expansion of the suspensoria. BassBot reproduced faithful kinematic and pressure dynamics relative to live bass. We show that motor program speed has a direct relationship to subambient pressure generation. Like vertebrate muscle, the linear motors that powered kinematics were able to produce larger magnitudes of force at slower velocities and, thus, were able to accelerate linkages more quickly and generate larger magnitudes of subambient pressure. In addition, we demonstrate that disrupting the kinematic behavior of the hyoid interferes with the anterior-to-posterior expansion gradient. This resulted in a significant reduction in subambient pressure generation and pressure impulse of 51% and 64%, respectively. These results reveal the promise biorobotic models have for isolating individual parameters and assessing

  16. Effect of Zr Purity and Oxygen Content on the Structure and Mechanical Properties of Melt-Spun and Suction-Cast Cu46Zr42Al7Y5 Alloy

    Directory of Open Access Journals (Sweden)

    Kozieł T.

    2016-06-01

    Full Text Available The effect of oxygen content in zirconium on the structure and mechanical properties of the Cu46Zr42Al7Y5 alloy, in the form of melt-spun ribbons and suction-cast rods, was investigated. Two types of Zr, rod and crystal bar of different nominal purities and oxygen contents, were used to synthesize the alloy by arc melting. Rapidly solidified ribbons were produced by melt spinning and their amorphous structures were confirmed by X-ray diffractometry (XRD and differential scanning calorimetry (DSC. Bulk samples in the form of rods were cast using a special water-cooled suction casting unit attached to the arc melting system. XRD and DSC studies proved the amorphous structure of the bulk alloy synthesized from low-oxygen Zr and partial crystallization of the same alloy for high-oxygen Zr. In both bulk samples, uniformly distributed crystalline particles were identified as yttrium oxides. Higher mean compressive strength of amorphous alloy was observed. The hardness of amorphous phase was close to 500 HV1 in both bulk alloys, while the hardness of crystalline dendritic areas, observed in the alloy synthesized from high oxygen Zr, was lower by about 50 HV1.

  17. Filter for underground mining for suction of preferably full cut and part cut machines, to be provided with preheated air, to avoid dropping below the dew point

    Energy Technology Data Exchange (ETDEWEB)

    Hoelter, H.

    1976-10-28

    Particularly when cutting hard rock, the cutting room to be provided with suction is wetted with water from nozzles, which, when sucking out air containing dust with high humidity leads to encrustation in the filter cloth. In order to avoid this, it is proposed that the air should be heated, using heat from the motor driving the ventilator, so that one avoids dropping below the dew point in the filter.

  18. Effect of continuous oral suctioning on the development of ventilator-associated pneumonia: a pilot randomized controlled trial.

    Science.gov (United States)

    Chow, Meyrick C M; Kwok, Shu-Man; Luk, Hing-Wah; Law, Jenny W H; Leung, Bartholomew P K

    2012-11-01

    Both continuous and intermittent aspiration of subglottic secretions by means of specially designed endotracheal tubes containing a separate dorsal lumen that opens into the subglottic region have been shown to be useful in reducing ventilator-associated pneumonia (VAP). However, the high cost of these tubes restricts their use. The aim of this pilot randomized controlled trial was to test the effect of a low-cost device (saliva ejector) for continuous oral suctioning (COS) on the incidence of VAP in patients receiving mechanical ventilation. The study was conducted in the six-bed medical-surgical ICU of a hospital with over 400 beds that provides comprehensive medical services to the public. The design of this study was a parallel-group randomized controlled trial. While both the experimental and control groups used the conventional endotracheal tube, the saliva ejector was only applied to patients assigned to the experimental group. The device was put between the patient's cheek and teeth, and then connected to 100mmHg of suction for the continuous drainage of saliva. Fourteen patients were randomized to receive COS and 13 patients were randomized to the control group. The two groups were similar in demographics, reasons for intubation, co-morbidity, and risk factors for acquiring VAP. VAP was found in 3 patients (23.1%; 71 episodes of VAP per 1000 ventilation days) receiving COS and in 10 patients (83.3%; 141 episodes of VAP per 1000 ventilation days) in the control group (relative risk, 0.28; 95% confidence interval, 0.10-0.77; p=0.003). The duration of mechanical ventilation in the experimental group was 3.2 days (SD 1.3), while that in the control group was 5.9 days (SD 2.8) (p=0.009); and the length of ICU stay was 4.8 days (SD 1.6) versus 9.8 days (SD 6.3) for the experimental and control groups, respectively (p=0.019). Continuous clearance of oral secretion by the saliva ejector may have an important role to play in reducing the rate of VAP, decreasing the

  19. Recirculation pump suction line 2.8% break integral test at ROSA-III with HPCS failure, RUN 984

    International Nuclear Information System (INIS)

    Suzuki, Mitsuhiro; Anoda, Yoshinari; Tasaka, Kanji; Kumamaru, Hiroshige; Nakamura, Hideo; Yonomoto, Taisuke; Murata, Hideo; Shiba, Masayoshi

    1984-06-01

    This report presents the experimental data of 2.8% suction line break test RUN 984 at ROSA-III, which was conducted as one of counterpart tests to FIST program sponsored by GE, EPRI and USNRC. The similarity study between the ROSA-III and FIST tests is on the way. The report also presents the information on the ROSA-III test facility, experiment results and the effects of the ADS flow rate and the MSIV trip level comparing with the previously conducted ROSA-III small break tests, RUNs 920 and 922. Major conclusions obtained are as follows. (1) Change of the MSIV trip level from L2 to L1 gives delay of MSIV closure and longer actuation of pressure control system in a small break LOCA. (2) Larger ADS flow gives faster depressurization rate and earlier ECCS actuation, which results in shorter fuel rod dryout period and lower PCT. (author)

  20. Work Turbochargers under Reduced Pressure in the Suction Pipe

    Directory of Open Access Journals (Sweden)

    I. V. Filippov

    2014-01-01

    Full Text Available In case consumers have a significant need in the compressed air, the use of turbochargers is a promising direction. The turbocharger operation is largely defined by its running conditions, namely parameters of the intake air and cooling conditions.The paper presents the results of experimental studies of turbochargers type 4CI 425MX4 of series "CENTAC" manufactured by INGERSOL-RAND, which were performed under industrial conditions in a mountainous area with difficult climatic conditions. There were, essentially, no researches of running turbochargers in mountainous areas. The combination of low atmospheric pressure, high temperature of intake air, and specific cooling conditions causes abnormal mode of turbocharger operation. The results of theoretical studies of such modes are found only in N.M. Barannikov’s work while there is no mentioned empirical research at all.Experimental studies were conducted under industrial conditions in the form of passive experiment. All measurements were carried out using a standard measuring system included in the system of compressor monitor and control. During the experimental studies temperature regimes at the turbocharger stage were controlled, and turbocharger pressure ratio and weight output were determined.The results of the research can be formulated as follows:- highland conditions and seasonal variations of atmospheric air have a negative impact on the operation of the turbochargers;- specific work value as an indicator of the economical efficiency exceeds that of the nameplate by 12...21 % depending on the climatic conditions.The problem of functioning normalization of the turbochargers seems to be relevant not only for the considered type of compressor, but also for that of the less power. It is proposed to consider two ways:- installation of the fifth additional stage;- mechanical pressurization in the suction pipe by means of blowers of high power.To make final decision it is necessary to conduct

  1. Aparelho de sucção tipo aspirador para captura de mosquitos A "vacuum-cleaner" type of suction apparatus for the collection of mosquitoes

    Directory of Open Access Journals (Sweden)

    Délsio Natal

    1984-10-01

    Full Text Available É feita a descrição de aparelho portátil de sucção tipo aspirador, para captura de mosquitos Culicidae. São sugeridas adaptações para coletas em diferentes situações. São feitos comentários sobre sua aplicação em pesquisa de mosquitos.A portable suction apparatus, which functions like a vacuum cleaner used for the collection of Culicidae mosquitoes is described. Adaptations for collecting in differents situations are suggested and some comments about its application in mosquitoes surveys are made.

  2. Effects of cellulite treatment with RF, IR light, mechanical massage and suction treating one buttock with the contralateral as a control.

    Science.gov (United States)

    Romero, Carmen; Caballero, Natalia; Herrero, Montse; Ruíz, Raquel; Sadick, Neil S; Trelles, Mario A

    2008-12-01

    A system that combines bipolar radio frequency (RF) and intense infrared light (IR) together with mechanical massage and suction has recently been reported as being efficient for cellulite treatment. The present split study was designed to evaluate the efficacy of such a system through various treatments of cellulite located on the buttocks. Ten patients were enrolled for 12 sessions of 30 minutes each performed over one buttock, the other buttock serving as an untreated control. Sessions were conducted twice a week for a period of 12 weeks. Clinical photography and profilometry were carried out to assess textural changes before (baseline) and 2 months after the final treatment. Histopathology was performed at baseline, 2 hours after the first session, and just before the 12th session and 2 months thereafter. All patients noted improvement in the treated buttock before the final session, which was maintained at the 2-month assessment. Improved skin appearance was noticed after the first session and was maintained throughout the study. All patients were satisfied with the results and requested further treatment in order to balance the results in both buttocks. Random histological analyses suggested dermal firmness, fibre compaction and tightening of skin layers, including the subcutis, as possible reasons for the effects achieved. The authors recognize that the small number of participants limits the statistical power of the study. Treatment sessions with the combined RF, IR light and mechanical massage and suction system were complication free, produced improvements in the overall cellulite appearance and skin condition, suggesting that further treatment sessions for maintenance could sustain patient satisfaction index (SI) and lead to lasting results. Based on the good results in the limited trial population, further studies with larger patient populations are warranted.

  3. Longitudinal effects of single-dose simulation education with structured debriefing and verbal feedback on endotracheal suctioning knowledge and skills: A randomized controlled trial.

    Science.gov (United States)

    Jansson, Miia M; Syrjälä, Hannu P; Ohtonen, Pasi P; Meriläinen, Merja H; Kyngäs, Helvi A; Ala-Kokko, Tero I

    2017-01-01

    We evaluated the longitudinal effects of single-dose simulation education with structured debriefing and verbal feedback on critical care nurses' endotracheal suctioning knowledge and skills. To do this we used an experimental design without other competing intervention. Twenty-four months after simulation education, no significant time and group differences or time × group interactions were identified between the study groups. The need for regularly repeated educational interventions with audiovisual or individualized performance feedback and repeated bedside demonstrations is evident. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Effect of chemical reaction, heat and mass transfer on nonlinear boundary layer past a porous shrinking sheet in the presence of suction

    International Nuclear Information System (INIS)

    Muhaimin; Kandasamy, Ramasamy; Hashim, Ishak

    2010-01-01

    This work is concerned with the viscous flow due to a shrinking sheet in the presence of suction with variable stream conditions. The cases of two-dimensional and axisymmetric shrinking have been discussed. The governing partial differential equations of the problem, subjected to their boundary conditions, are solved numerically by applying an efficient solution scheme for local nonsimilarity boundary layer analysis. Favorable comparison with previously published work is performed. Numerical results for the dimensionless velocity, temperature and concentration profiles as well as for the skin friction, heat and mass transfer and deposition rate are obtained and displayed graphically for pertinent parameters to show interesting aspects of the solution.

  5. Right vs. left sensorimotor cortex suction-ablation in the rat: no difference in beam-walking recovery.

    Science.gov (United States)

    Goldstein, L B

    1995-03-13

    The ability of rats to traverse a narrow elevated beam has been used to quantitate recovery of hindlimb motor function after unilateral injury to the sensorimotor cortex. We tested the hypothesis that the rate of spontaneous beam-walking recovery varies with the side of the cortex lesion. Groups of rats that were trained at the beam-walking task underwent suction-ablation of either the right or left hindlimb sensorimotor cortex. There was no difference in hindlimb motor function between the groups on the first post-operative beam-waking trial carried out the day after cortex ablation and no difference between the groups in overall recovery rates over the next two weeks. Subsequent analyses of lesion surface parameters showed no differences in lesion size or extent. Regardless of the side of the lesion, there were also no differences between the right and left hemispheres in norepinephrine content of the lesioned or contralateral cortex. We conclude that the side of sensorimotor cortex ablation injury does not differentially affect the rate of spontaneous motor recovery as measured with the beam-walking task.

  6. Pengaruh unsur Tembaga (Cu terhadap fluiditas paduan Al-Si 11.8 wt% (ADC 12 dengan metode Vacuum Suction Test

    Directory of Open Access Journals (Sweden)

    Bambang Suharno

    2012-11-01

    Full Text Available Al-Si 11.8 wt% alloy which classified to eutectic Al-Si composition usually used to produce a flat casting product with high pressure die casting process. Alloying element become an important things to determine behavior and characteristic of aluminum. Copper added into aluminum to improve strength and hardness, but there has no many studies on the effect of copper on fluidity. This fluidity study is using vacuum suction test method and the microstructure is observed with SEM/EDS. Spectrometer test has been used to find out chemical composition of sample. The result of this study shows that with copper addition from 2.25 wt% to 3.11 wt%, the fluidity value has increased 24.11% on 680oC pouring temperature. On 3.11 wt% copper composition, fluidity value has increased 14.38% from 640oC pouring temperature to 700oC pouring temperature.

  7. Report on technical measurements concerning measurement of the suction of tanks at Fangel biomass conversion plant

    International Nuclear Information System (INIS)

    1992-05-01

    The inconveniences caused by the odours emerging from the biomass conversion plant in Fangel, Denmark, and the actions taken in an attempt to reduce them, are described. The plant has on several occasions been threatened with being closed down because of the smell. Airtight coverings have been fixed on all the open tanks, and the suction element has been tested to see if it is airtight. Ozone has been added in order to help get rid of the smell. Measurements have shown that it is possible to attain a small vacuum in the storage tank under normal operation, if there is a surfeit of pumping there will be too high pressure. In relation to pumping-in the pressure can be too high in the first and medium tank. Flow, pressure, hydrogen sulphide and methane concentration changes significantly in relation to the various pumping frequences. The level of hydrogen sulphide removal in the biofilter was 70-85%. The flow of hydrogen sulphide becomes less after the addition of ozone. Measurements implied that the tanks were airtight. Larger vacuums can be achieved by changing the shape of the pipe system and increasing the flow. (AB)

  8. In Vitro Evaluation of Evacuated Blood Collection Tubes as a Closed-Suction Surgical Drain Reservoir.

    Science.gov (United States)

    Heiser, Brian; Okrasinski, E B; Murray, Rebecca; McCord, Kelly

    The initial negative pressures of evacuated blood collection tubes (EBCT) and their in vitro performance as a rigid closed-suction surgical drain (CSSD) reservoir has not been evaluated in the scientific literature despite being described in both human and veterinary texts and journals. The initial negative pressures of EBCT sized 3, 6, 10, and 15 mL were measured and the stability of the system monitored. The pressure-to-volume curve as either air or water was added and maximal filling volumes were measured. Evacuated blood collection tubes beyond the manufacture's expiration date were evaluated for initial negative pressures and maximal filling volumes. Initial negative pressure ranged from -214 mm Hg to -528 mm Hg for EBCT within the manufacturer's expiration date. Different pressure-to-volume curves were found for air versus water. Optimal negative pressures of CSSD are debated in the literature. Drain purpose and type of exudates are factors that should be considered when deciding which EBCT size to implement. Evacuated blood collection tubes have a range of negative pressures and pressure-to-volume curves similar to previously evaluated CSSD rigid reservoirs. Proper drain management and using EBCT within labeled expiration date are important to ensure that expected negative pressures are generated.

  9. Effect of a syringe aspiration technique versus a mechanical suction technique and use of N-butylscopolammonium bromide on the quantity and quality of bronchoalveolar lavage fluid samples obtained from horses with the summer pasture endophenotype of equine asthma.

    Science.gov (United States)

    Bowser, Jacquelyn E; Costa, Lais R R; Rodil, Alba U; Lopp, Christine T; Johnson, Melanie E; Wills, Robert W; Swiderski, Cyprianna E

    2018-03-01

    OBJECTIVE To evaluate the effect of 2 bronchoalveolar lavage (BAL) sampling techniques and the use of N-butylscopolammonium bromide (NBB) on the quantity and quality of BAL fluid (BALF) samples obtained from horses with the summer pasture endophenotype of equine asthma. ANIMALS 8 horses with the summer pasture endophenotype of equine asthma. PROCEDURES BAL was performed bilaterally (right and left lung sites) with a flexible videoendoscope passed through the left or right nasal passage. During lavage of the first lung site, a BALF sample was collected by means of either gentle syringe aspiration or mechanical suction with a pressure-regulated wall-mounted suction pump. The endoscope was then maneuvered into the contralateral lung site, and lavage was performed with the alternate fluid retrieval technique. For each horse, BAL was performed bilaterally once with and once without premedication with NBB (21-day interval). The BALF samples retrieved were evaluated for volume, total cell count, differential cell count, RBC count, and total protein concentration. RESULTS Use of syringe aspiration significantly increased total BALF volume (mean volume increase, 40 mL [approx 7.5% yield]) and decreased total RBC count (mean decrease, 142 cells/μL), compared with use of mechanical suction. The BALF nucleated cell count and differential cell count did not differ between BAL procedures. Use of NBB had no effect on BALF retrieval. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that retrieval of BALF by syringe aspiration may increase yield and reduce barotrauma in horses at increased risk of bronchoconstriction and bronchiolar collapse. Further studies to determine the usefulness of NBB and other bronchodilators during BAL procedures in horses are warranted.

  10. H-M bearing capacity of a modified suction caisson determined by using load-/displacement-controlled methods

    Science.gov (United States)

    Zhang, Yu-kun; Gao, Yu-feng; Li, Da-yong; Mahfouz, Ali H.

    2016-12-01

    This paper presents a series of monotonically combined lateral loading tests to investigate the bearing capacity of the MSCs (modified suction caissons) in the saturated marine fine sand. The lateral loads were applied under load- and displacement-controlled methods at the loading eccentricity ratios of 1.5, 2.0 and 2.5. Results show that, in the displacement-controlled test, the deflection-softening behavior of load-deflection curves for MSCs was observed, and the softening degree of the load-deflection response increased with the increasing external skirt length or the decreasing loading eccentricity. It was also found that the rotation center of the MSC at failure determined by the load-controlled method is slightly lower than that by the displacement-controlled method. The calculated MSC capacity based on the rotation center position in serviceability limit state is relatively conservative, compared with the calculated capacity based on the rotation center position in the ultimate limit state. In the limit state, the passive earth pressures opposite the loading direction under load- and displacement-controlled methods decrease by 46% and 74% corresponding to peak values, respectively; however, the passive earth pressures in the loading direction at failure only decrease by approximately 3% and 7%, compared with their peak values.

  11. Glioma tissue obtained by modern ultrasonic aspiration with a simple sterile suction trap for primary cell culture and pathological evaluation.

    Science.gov (United States)

    Schroeteler, Juliane; Reeker, Ralf; Suero Molina, Eric; Brokinkel, Benjamin; Holling, Markus; Grauer, Oliver M; Senner, Volker; Stummer, Walter; Ewelt, Christian

    2014-01-01

    Ultrasonic aspiration is widely used in the resection of brain tumors. Nevertheless, tumor tissue fragments obtained by ultrasonic aspiration are usually discarded. In this study, we demonstrate that these fragments are possible sources of material for histopathological study and tissue culture and compare their microscopic features and viability in tissue culture of cavitron ultrasonic surgical aspirator tissue fragments. Brain tumor tissue collected by ultrasonic aspiration (CUSA EXcel®; Integra Radionics Inc.) in a simple sterile suction trap during resection was processed for primary cell culture. Cell viability and immunohistological markers were measured by the WST-1 test, microscopy and immunofluorescent evaluation. Six gliomas are presented to demonstrate that these tissue fragments show good preservation of histological detail and tissue viability in culture. Utilization of this material may facilitate pathological interpretation by providing a more representative sample of tumor histology as well as an adequate and sterile biosource of material for tissue culture studies.

  12. Diastolic Backward-Traveling Decompression (Suction) Wave Correlates With Simultaneously Acquired Indices of Diastolic Function and Is Reduced in Left Ventricular Stunning.

    Science.gov (United States)

    Ladwiniec, Andrew; White, Paul A; Nijjer, Sukhjinder S; O'Sullivan, Michael; West, Nick E J; Davies, Justin E; Hoole, Stephen P

    2016-09-01

    Wave intensity analysis can distinguish proximal (propulsion) and distal (suction) influences on coronary blood flow and is purported to reflect myocardial performance and microvascular function. Quantifying the amplitude of the peak, backwards expansion wave (BEW) may have clinical utility. However, simultaneously acquired wave intensity analysis and left ventricular (LV) pressure-volume loop data, confirming the origin and effect of myocardial function on the BEW in humans, have not been previously reported. Patients with single-vessel left anterior descending coronary disease and normal ventricular function (n=13) were recruited prospectively. We simultaneously measured LV function with a conductance catheter and derived wave intensity analysis using a pressure-low velocity guidewire at baseline and again 30 minutes after a 1-minute coronary balloon occlusion. The peak BEW correlated with the indices of diastolic LV function: LV dP/dtmin (rs=-0.59; P=0.002) and τ (rs=-0.59; P=0.002), but not with systolic function. In 12 patients with paired measurements 30 minutes post balloon occlusion, LV dP/dtmax decreased from 1437.1±163.9 to 1299.4±152.9 mm Hg/s (median difference, -110.4 [-183.3 to -70.4]; P=0.015) and τ increased from 48.3±7.4 to 52.4±7.9 ms (difference, 4.1 [1.3-6.9]; P=0.01), but basal average peak coronary flow velocity was unchanged, indicating LV stunning post balloon occlusion. However, the peak BEW amplitude decreased from -9.95±5.45 W·m(-2)/s(2)×10(5) to -7.52±5.00 W·m(-2)/s(2)×10(5) (difference 2.43×10(5) [0.20×10(5) to 4.67×10(5); P=0.04]). Peak BEW assessed by coronary wave intensity analysis correlates with invasive indices of LV diastolic function and mirrors changes in LV diastolic function confirming the origin of the suction wave. This may have implications for physiological lesion assessment after percutaneous coronary intervention. URL: http://www.isrctn.org. Unique identifier: ISRCTN42864201. © 2016 American Heart

  13. Effects of bilateral and unilateral locus coeruleus lesions on beam-walking recovery after subsequent unilateral sensorimotor cortex suction-ablation in the rat.

    Science.gov (United States)

    Goldstein, L B

    1997-01-01

    The recovery of beam-walking ability following a unilateral sensorimotor cortex lesion in the rat is hypothesized to be noradrenergically-mediated. We carried out two experiments to further test this hypothesis. In the first experiment, bilateral 6-hydroxydopamine locus coeruleus (LC) lesions or sham LC lesions were made 2 weeks prior to a right sensorimotor cortex suction-ablation lesion or sham cortex lesion. In the second experiment, unilateral left or right LC lesions or sham LC lesions were made 2 weeks prior to a right sensorimotor cortex lesion or sham cortex lesion. Beam-walking recovery was measured over the 12 days following cortex lesioning in each experiment. Bilateral, unilateral left, and unilateral right LC lesions resulted in impaired recovery. These data provide additional support for the hypothesis that beam-walking recovery after sensorimotor cortex injury is, at least in part, noradrenergically mediated.

  14. Suction catheter guided insertion of ProSeal laryngeal mask airway: Experience by untrained physicians

    Directory of Open Access Journals (Sweden)

    Valter Perilli

    2014-01-01

    Full Text Available Background: The use of suction catheter (SC has been shown to improve success rate during ProSeal laryngeal mask airway (PLMA insertion in expert users. Aims: The aim of this study was to compare insertion of PLMA performed by untrained physicians using a SC or the digital technique (DT in anaesthetised non-paralysed patients. Methods: In this prospective randomised double-blind study, conducted in the operating setting, 254 patients (American Society of Anaesthesiologists I-II, aged 18-65 years, undergoing minor surgery were enrolled. Exclusion criteria were body mass index >35 kg/m 2 , laryngeal or oesophageal varices, risk of aspiration or difficult face mask ventilation either referred or suspected (Langeron′s criteria ≥2 and modified Mallampati classification score >2. Participants were randomly allocated to one of the two groups in which PLMA was inserted using DT (DT-group or SC (SC-group. Statistical Analysis: Chi-square test with Yates′ correction, Mann-Whitney U-test or Student′s t-test were carried-out as appropriate. Results: The final insertion success rate was greater in SC-groupcompared with DT-group 90.1% (n = 109 versus 74.4% (n = 99 respectively (P = 0.002. Mean airway leak pressure was higher in SC-group compared to DT-group (23.7 ± 3.9 vs. 21.4 ± 3.2 respectively; (P = 0.001. There were no differences in insertion time, post-operative airway morbidity and complications. Conclusion: The findings of this study suggest that SC-technique improves the success rate of PLMA insertion by untrained physicians.

  15. On exact solutions for disturbances to the asymptotic suction boundary layer: transformation of Barnes integrals to convolution integrals

    Science.gov (United States)

    Russell, John

    2000-11-01

    A modified Orr-Sommerfeld equation that applies to the asymptotic suction boundary layer was reported by Bussmann & Münz in a wartime report dated 1942 and by Hughes & Reid in J.F.M. ( 23, 1965, p715). Fundamental systems of exact solutions of the Orr-Sommerfeld equation for this mean velocity distribution were reported by D. Grohne in an unpublished typescript dated 1950. Exact solutions of the equation of Bussmann, Münz, Hughes, & Reid were reported by P. Baldwin in Mathematika ( 17, 1970, p206). Grohne and Baldwin noticed that these exact solutions may be expressed either as Barnes integrals or as convolution integrals. In a later paper (Phil. Trans. Roy. Soc. A, 399, 1985, p321), Baldwin applied the convolution integrals in the contruction of large-Reynolds number asymptotic approximations that hold uniformly. The present talk discusses the subtleties that arise in the construction of such convolution integrals, including several not reported by Grohne or Baldwin. The aim is to recover the full set of seven solutions (one well balanced, three balanced, and three dominant-recessive) postulated by W.H. Reid in various works on the uniformly valid solutions.

  16. Parametric study of a capillary tube-suction line heat exchanger in a transcritical CO2 heat pump cycle

    International Nuclear Information System (INIS)

    Agrawal, Neeraj; Bhattacharyya, Souvik

    2008-01-01

    The capillary tube in a transcritical CO 2 system behaves differently as temperature and pressure are two independent parameters unlike those in a sub-critical cycle. A capillary tube-suction line heat exchanger (CL-SLHX) in a transcritical vapour compression cycle considering homogeneous two-phase flow is modelled in this study based on mass, energy and momentum equations. Effects of gas cooler temperature, evaporator temperature and internal diameter of capillary tube are investigated. Heat transfer rate is observed to be influenced by refrigerant quality, mass flow rate and the prevailing temperature difference. Heat transfer rate variation with gas cooler temperature is unique, recording an initial increase followed by a decrease. Frictional pressure drop influences the heat transfer; consequently, chances of re-condensation of refrigerant vapour are very marginal. Larger diameter of capillary tube leads to increase in refrigerant mass flow rate and increase in heat transfer rate as well. Shorter inlet adiabatic capillary length with larger heat exchanger length is better for heat transfer. This study is an attempt to dispel the scepticism prevailing in transcritical CO 2 system community overemphasising the need for a throttle valve to control the optimum discharge pressure

  17. Improved upper bounds on energy dissipation rates in plane Couette flow with boundary injection and suction

    Science.gov (United States)

    Lee, Harry; Wen, Baole; Doering, Charles

    2017-11-01

    The rate of viscous energy dissipation ɛ in incompressible Newtonian planar Couette flow (a horizontal shear layer) imposed with uniform boundary injection and suction is studied numerically. Specifically, fluid is steadily injected through the top plate with a constant rate at a constant angle of injection, and the same amount of fluid is sucked out vertically through the bottom plate at the same rate. This set-up leads to two control parameters, namely the angle of injection, θ, and the Reynolds number of the horizontal shear flow, Re . We numerically implement the `background field' variational problem formulated by Constantin and Doering with a one-dimensional unidirectional background field ϕ(z) , where z aligns with the distance between the plates. Computation is carried out at various levels of Re with θ = 0 , 0 .1° ,1° and 2°, respectively. The computed upper bounds on ɛ scale like Re0 as Re > 20 , 000 for each fixed θ, this agrees with Kolmogorov's hypothesis on isotropic turbulence. The outcome provides new upper bounds to ɛ among any solution to the underlying Navier-Stokes equations, and they are sharper than the analytical bounds presented in Doering et al. (2000). This research was partially supported by the NSF Award DMS-1515161, and the University of Michigan's Rackham Graduate Student Research Grant.

  18. Investigation on inlet recirculation characteristics of double suction centrifugal compressor with unsymmetrical inlet

    Science.gov (United States)

    Yang, Ce; Wang, Yingjun; Lao, Dazhong; Tong, Ding; Wei, Longyu; Liu, Yixiong

    2016-08-01

    The inlet recirculation characteristics of double suction centrifugal compressor with unsymmetrical inlet structures were studied in numerical method, mainly focused on three issues including the amounts and differences of the inlet recirculation in different working conditions, the circumferential non-uniform distributions of the inlet recirculation, the recirculation velocity distributions of the upstream slot of the rear impeller. The results show that there are some differences between the recirculation of the front impeller and that of the rear impeller in whole working conditions. In design speed, the recirculation flow rate of the rear impeller is larger than that of the front impeller in the large flow range, but in the small flow range, the recirculation flow rate of the rear impeller is smaller than that of the front impeller. In different working conditions, the recirculation velocity distributions of the front and rear impeller are non-uniform along the circumferential direction and their non-uniform extents are quite different. The circumferential non-uniform extent of the recirculation velocity varies with the working conditions change. The circumferential non-uniform extent of the recirculation velocity of front impeller and its distribution are determined by the static pressure distribution of the front impeller, but that of the rear impeller is decided by the coupling effects of the inlet flow distortion of the rear impeller, the circumferential unsymmetrical distribution of the upstream slot and the asymmetric structure of the volute. In the design flow and small flow conditions, the recirculation velocities at different circumferential positions of the mean line of the upstream slot cross-section of the rear impeller are quite different, and the recirculation velocities distribution forms at both sides of the mean line are different. The recirculation velocity distributions in the cross-section of the upstream slot depend on the static pressure

  19. Application of a compressible flow solver and barotropic cavitation model for the evaluation of the suction head in a low specific speed centrifugal pump impeller channel

    International Nuclear Information System (INIS)

    Limbach, P; Müller, T; Skoda, R

    2015-01-01

    Commonly, for the simulation of cavitation in centrifugal pumps incompressible flow solvers with VOF kind cavitation models are applied. Since the source/sink terms of the void fraction transport equation are based on simplified bubble dynamics, empirical parameters may need to be adjusted to the particular pump operating point. In the present study a barotropic cavitation model, which is based solely on thermodynamic fluid properties and does not include any empirical parameters, is applied on a single flow channel of a pump impeller in combination with a time-explicit viscous compressible flow solver. The suction head curves (head drop) are compared to the results of an incompressible implicit standard industrial CFD tool and are predicted qualitatively correct by the barotropic model. (paper)

  20. Hábitos orais de sucção: estudo piloto em população de baixa renda Suction oral habits: initial study in low income population

    Directory of Open Access Journals (Sweden)

    Valdinês G.S. Cavassani

    2003-01-01

    Full Text Available Hábitos orais de sucção têm sido fonte de estudo pelos danos que podem causar em toda morfologia e função do sistema estomatognático, sendo comumente iniciados e observados na infância. Fatores emocionais e nutricionais podem contribuir para a manifestação desses hábitos. OBJETIVO: Verificar alterações fonoaudiológicas, odontológicas e otorrinolaringológicas em crianças de baixa renda portadoras de hábitos orais de sucção. FORMA DE ESTUDO: Clínico retrospectivo não randomizado. MATERIAL E MÉTODO: Foram avaliadas nove crianças (01 menino e 08 meninas com idades entre 5 a 9 anos durante o I Mutirão da Comunicação realizado no Hosphel, São Paulo, no dia 27 de outubro de 2001. RESULTADOS: O distúrbio fonoaudiológico mais comum foi o articulatório (55,56%, seguido pelo distúrbio de motricidade oral (33,33%. A mordida aberta esteve presente em 8 casos (88,89%. Com relação ao tipo de respiração apresentou-se com 7 casos com respiração bucal (77,78%. CONCLUSÕES: Os hábitos orais foram capazes de promover alterações fonoaudiológicas, odontológicas e otorrinolaringológicas. Medidas de promoção de saúde devem ser lançadas para crianças de baixa renda visando eliminar os fatores responsáveis pela origem dos hábitos orais viciosos de sucção, tais como: alimentação e educação. Além de medidas de tratamento multidisciplinar, devem ser estabelecidas fonoaudiologia, ortodontia, otorrinolaringologia em saúde pública, solucionando o paradigma das alterações decorrentes desses hábitos comumente perceptíveis na infância.Suction oral habits have been observed in childhood due to emotional and nutritional factors, leading to dental and speech and voice consequences. OBJECTIVE: The purpose of this study was the observation of dental and speech and articulation abnormalities in low-income children with suction oral habits. STUDY DESIGN: Retrospective clinical non randomized study. MATERIAL AND METHOD

  1. Effect of plate permeability on nonlinear stability of the asymptotic suction boundary layer.

    Science.gov (United States)

    Wedin, Håkan; Cherubini, Stefania; Bottaro, Alessandro

    2015-07-01

    The nonlinear stability of the asymptotic suction boundary layer is studied numerically, searching for finite-amplitude solutions that bifurcate from the laminar flow state. By changing the boundary conditions for disturbances at the plate from the classical no-slip condition to more physically sound ones, the stability characteristics of the flow may change radically, both for the linearized as well as the nonlinear problem. The wall boundary condition takes into account the permeability K̂ of the plate; for very low permeability, it is acceptable to impose the classical boundary condition (K̂=0). This leads to a Reynolds number of approximately Re(c)=54400 for the onset of linearly unstable waves, and close to Re(g)=3200 for the emergence of nonlinear solutions [F. A. Milinazzo and P. G. Saffman, J. Fluid Mech. 160, 281 (1985); J. H. M. Fransson, Ph.D. thesis, Royal Institute of Technology, KTH, Sweden, 2003]. However, for larger values of the plate's permeability, the lower limit for the existence of linear and nonlinear solutions shifts to significantly lower Reynolds numbers. For the largest permeability studied here, the limit values of the Reynolds numbers reduce down to Re(c)=796 and Re(g)=294. For all cases studied, the solutions bifurcate subcritically toward lower Re, and this leads to the conjecture that they may be involved in the very first stages of a transition scenario similar to the classical route of the Blasius boundary layer initiated by Tollmien-Schlichting (TS) waves. The stability of these nonlinear solutions is also investigated, showing a low-frequency main unstable mode whose growth rate decreases with increasing permeability and with the Reynolds number, following a power law Re(-ρ), where the value of ρ depends on the permeability coefficient K̂. The nonlinear dynamics of the flow in the vicinity of the computed finite-amplitude solutions is finally investigated by direct numerical simulations, providing a viable scenario for

  2. A Randomized Study of Minimally Invasive Percutaneous Nephrolithotomy (MPCNL) with the aid of a patented suctioning sheath in the treatment of renal calculus complicated by pyonephrosis by one surgery.

    Science.gov (United States)

    Huang, Jianrong; Song, Leming; Xie, Donghua; Li, Monong; Deng, Xiaolin; Hu, Min; Peng, Zuofeng; Liu, Tairong; Du, Chuance; Yao, Lei; Liu, Shengfeng; Guo, Shulin; Zhong, Jiuqing

    2016-12-08

    Calculus pyonephrosis is difficult to manage. The aim of this study is to explore the value of a patented suctioning sheath assisted minimally invasive percutaneous nephrolithotomy (MPCNL) in the treatment of calculus pyonephrosis. One hundred and eighty two patients with calculus pyonephrosis were randomizely divided into observation group (n = 91) and control group (n = 91). The control group was treated with MPCNL traditionally using peel-away sheath while the observation group was treated with MPCNL using the patented suctioning sheath. All the patients in the observation group underwent one stage surgical treatment, 14 patients in the control group underwent first-stage surgery with the rest of the group underwent one stage surgery. The complication rate was 12.1% in the observation group, significantly lower than the rate in the control group which was 51.6%; One surgery stone clearance in the observation group was 96.7% while it was 73.6% in the control group; operative time in the observation group was (54.5 ± 14.5) min, compared to (70.2 ± 11.7) min in the control group; the bleeding amount in the observation group was (126.4 ± 47.2) ml, compared to (321.6 ± 82.5) ml in the control group; the hospitalization duration for the observation group was (6.4 ± 2.3) days, compared to (10.6 ± 3.7) days in the control group. Comparison of the above indicators, the observation group was better than the control group with significant difference (p calculus pyonephrosis in one surgery is economic, practical, and warrants clinical promotion. This study was registered with Chinese Clinical Trial Registry on May 18, 2016 (retrospective registration) with a trial registration number of ChiCTR-IOR-16008490 .

  3. Comparison in processing routes by copper mold casting injection and suction in the Cu{sub 46}Zr{sub 42}Al{sub 7}Y{sub 5} vitreous alloy; Comparacao entre as rotas de processamento por fundicao com injecao e com succao da liga vitrea Cu{sub 46}Zr{sub 42}Al{sub 7}Y{sub 5}

    Energy Technology Data Exchange (ETDEWEB)

    Batalha, W.; Aliaga, L.C.R.; Bolfarini, C.; Botta, W.J.; Kiminami, C.S. [Universidade Federal de Sao Carlos (UFSCar), SP (Brazil). Departamento de Engenharia de Materiais

    2014-07-01

    To expand the application of glassy metals, the development of processing routes and compositions that allow the production of parts with dimensions of millimeters or even centimeters, is very important. The present work aims the contribution to the technological development of processing routes for the production of Cu-based bulk metallic glasses. Wedge-shaped samples of Cu{sub 46}Zr{sub 42}Al{sub 7}Y{sub 5} (atom percent) chemical composition were processed using copper mold casting by suction and injection. Characterization was made combining scanning electron microscopy, x-ray diffraction and differential scanning calorimetry. The critical amorphous thickness obtained by those two different routes was carefully observed. The suction route allow obtaining the best results with critical amorphous thickness about 8 mm. This result was analyzed considering the different extrinsic parameters to the glass forming ability of the alloy. (author)

  4. A calculation method of the optimal distance of the long-drawn short-pressure type localfan in minebased on the principle of the jet and Suction volume

    Science.gov (United States)

    Fu, Shaotong

    2018-01-01

    In order to dilute the harmful smoke and dust of the working surface in the production of the roadway in the mine shaft, the combination of mine local ventilation is often considered when conditions permitting. However there is no definite method to determine the distance between fan and working surface. Considering the concentration of smoke, the size of working face, the ventilation time, the wind speed of the working face and the principle of suction volume, this paper analyzes the long - drawn short - pressure type of the ventilation scheme, and presents an optimal algorithm for the distance between the exhaust ventilator and the working face:{{L}}{{o}}=\\frac{{({{{v}}}{{f}}{{t}})}{{Z}}{{{S}}}{{o}}\\frac{\\exists }{{{z}}{{β }}}}{3.398{{{S}}}W\\frac{1}{{{z}}{{A}}}}. Then this paperpresentsa reference distance for different wind speed requirements of a project.

  5. Microstructure analysis of cofebsinb metallic glasses with a various geometry prepared by planar flow casting and suction casting methods

    International Nuclear Information System (INIS)

    Hosko, J.; Janotova, J.; Svec, P.; Matko, I.; Janickovic, D.; Svec, P. Sr.

    2012-01-01

    In this paper we have studied the structure of as-cast Co_4_7Fe_2_0_._9B_2_1_._2Si_4_._6Nb_6_._3 ribbon, bilayer and bulk samples in form of rods up to 5 mm diameter. Amorphous structure of the ribbons and bilayer prepared by PFC was confirmed by XRD characterization. XRD analysis of the bulk sample with 5 mm diameter indicated the presence of crystalline phases. However, XRD analysis of the bulk sample with 4 mm diameter indicated no significant crystalline peaks. From TEM analysis it was found that in-situ BMG composite was obtained in bulk sample. The edge of bulk sample with 4 mm diameter was fully amorphous, however, the center of this sample contains crystalline particles of micron sizes dispersed in the amorphous matrix. Our results suggest that the system Co_4_7Fe_2_0_._9B_2_1_._2Si_4_._6Nb_6_._3 has high GFA because we have prepared various amorphous materials with different shape and thickness using the techniques of suction casting, modified PFC and PFC. The critical diameter of bulk samples with chemical composition Co_4_7Fe_2_0_._9B_2_1_._2Si_4_._6Nb_6_._3 for emergence amorphous phase is 4 mm. (authors)

  6. Microstructure, mechanical property and corrosion behavior of interpenetrating (HA + β-TCP)/MgCa composite fabricated by suction casting

    International Nuclear Information System (INIS)

    Wang, X.; Dong, L.H.; Li, J.T.; Li, X.L.; Ma, X.L.; Zheng, Y.F.

    2013-01-01

    The novel interpenetrating (HA + β-TCP)/MgCa composites were fabricated by infiltrating MgCa alloy into porous HA + β-TCP using suction casting technique. The microstructure, mechanical properties and corrosion behaviors of the composites have been evaluated by means of scanning electron microscopy (SEM), X-ray diffraction (XRD), mechanical testing, electrochemical and immersion tests. It was shown that the composites had compact structure and the interfacial bonding between MgCa alloy and HA + β-TCP scaffolds was very well. The ultimate compressive strength of the composites was about 500–1000 fold higher than that of the original porous scaffolds, and it still retained quarter-half of the strength of the bulk MgCa alloy. The electrochemical and immersion tests indicated that the corrosion resistance of the composites was better than that of the MgCa matrix alloy, and the corrosion products of the composite surface were mainly Mg(OH) 2 , HA and Ca 3 (PO 4 ) 2 . Meanwhile, the mechanical and corrosive properties of the (HA + β-TCP)/MgCa composites were adjustable by the choice of HA content. - Highlights: • The composites were fabricated by infiltrating MgCa alloy into porous HA + β-TCP. • The microstructure, mechanical and corrosion properties were investigated. • It showed composites had compact structures and good interfacial bonding. • The mechanical and corrosive properties can be adjustable by the HA content. • The corrosion mechanism of the composite has been explained

  7. Magneto-hydrodynamics of coupled fluid–sheet interface with mass suction and blowing

    International Nuclear Information System (INIS)

    Ahmad, R.

    2016-01-01

    There are large number of studies which prescribe the kinematics of the sheet and ignore the sheet's mechanics. However, the current boundary layer analysis investigates the mechanics of both the electrically conducting fluid and a permeable sheet, which makes it distinct from the other studies in the literature. One of the objectives of the current study is to (i) examine the behaviour of magnetic field effect for both the surface and the electrically conducting fluid (ii) investigate the heat and mass transfer between a permeable sheet and the surrounding electrically conducting fluid across the hydro, thermal and mass boundary layers. Self-similar solutions are obtained by considering the RK45 technique. Analytical solution is also found for the stretching sheet case. The skin friction dual solutions are presented for various types of sheet. The influence of pertinent parameters on the dimensionless velocity, shear stress, temperature, mass concentration, heat and mass transfer rates on the fluid–sheet interface is presented graphically as well as numerically. The obtained results are of potential benefit for studying the electrically conducting flow over various soft surfaces such as synthetic plastics, soft silicone sheet and soft synthetic rubber sheet. These surfaces are easily deformed by thermal fluctuations or thermal stresses. - Highlights: • The momentum equation is modelled for both the surrounding MHD fluid and the sheet with the effects of mass suction and blowing. • The current study further investigates the heat and mass transfer characteristics between a permeable sheet and the surrounding electrically conducting fluid across the thermal and mass boundary layers. • Both the approximated and analytical techniques have been included for the purpose of comparison, and the perfect numerical agreements have been established with the previous studies. • Dual solutions for the skin friction coefficients are found for various categories of

  8. Cupping therapy: An analysis of the effects of suction on skin and the possible influence on human health.

    Science.gov (United States)

    Lowe, Duane T

    2017-11-01

    Cupping therapy is a traditional therapy that has been employed worldwide for thousands of years. Despite a lack of quality clinical studies evaluating the efficacy of cupping therapy, its long history and widespread use throughout the world suggests the commonly claimed health benefits should not be completely discounted as without merit. The goal of this paper is to present the research detailing what is known concerning the effects of suction on skin and underlying tissue, and the reaction of the body to that stimulus. Understanding the literature on the physiological effects of this mechanical force may help elaborate an explanation for the advertised local and systemic effects of cupping therapy. Negative pressure causes stretching of the skin and underlying tissue and dilation of the capillaries. This stimulates an increase in tissue blood flow, eventually leading to capillary rupture and ecchymosis. Macrophages phagocytize the erythrocytes in the extravascular space which stimulates the production of Heme Oxygenase-1 (HO-1) to metabolize the heme. Heme catalysis results in the production of carbon monoxide (CO), biliverdin(BV)/bilirubin(BR) and iron. HO-1, BV, BR, and CO has been shown to have antioxidant, anti-inflammatory, antiproliferative, and neuromodulatory effects in animal and human systems. These substances also stimulate a shift of macrophages to the anti-inflammatory M2 phenotype. There is evidence that the effects are both local and systemic. Besides the mechanical effect of cupping increasing the local blood flow and stretching underlying tissue, activation of the HO-1 system could account for many of cupping therapy's claimed local and systemic health benefits. Published by Elsevier Ltd.

  9. Effects of radial diffuser hydraulic design on a double-suction centrifugal pump

    Science.gov (United States)

    Hou, H. C.; Zhang, Y. X.; Xu, C.; Zhang, J. Y.; Li, Z. L.

    2016-05-01

    In order to study effects of radial diffuser on hydraulic performance of crude oil pump, the steady CFD numerical method is applied and one large double-suction oil pump running in long-distance pipeline is considered. The research focuses on analysing the influence of its diffuser vane profile on hydraulic performance of oil pump. The four different types of cylindrical vane have been designed by in-house codes mainly including double arcs (DA), triple arcs (TA), equiangular spiral line (ES) and linear variable angle spiral line (LVS). During design process diffuser vane angles at inlet and outlet are tentatively given within a certain range and then the wrapping angle of the four types of diffuser vanes can be calculated automatically. Under the given inlet and outlet angles, the linear variable angle spiral line profile has the biggest wrapping angle and profile length which is good to delay channel diffusion but bring more friction hydraulic loss. Finally the vane camber line is thickened at the certain uniform thickness distribution and the 3D diffuser models are generated. The whole flow passage of oil pump with different types of diffusers under various flow rate conditions are numerically simulated based on RNG k-ɛ turbulent model and SIMPLEC algorithm. The numerical results show that different types of diffusers can bring about great difference on the hydraulic performance of oil pump, of which the ES profile diffuser with its proper setting angle shows the best hydraulic performance and its inner flow field is improved obviously. Compared with the head data from model sample, all designed diffusers can make a certain improvement on head characteristic. At the large flow rate conditions the hydraulic efficiency increases obviously and the best efficiency point shift to the large flow rate range. The ES profile diffuser embodies the better advantages on pump performance which can be explained theoretically that the diffuser actually acts as a diffusion

  10. Effect of thermal radiation and chemical reaction on non-Newtonian fluid through a vertically stretching porous plate with uniform suction

    Science.gov (United States)

    Khan, Zeeshan; Khan, Ilyas; Ullah, Murad; Tlili, I.

    2018-06-01

    In this work, we discuss the unsteady flow of non-Newtonian fluid with the properties of heat source/sink in the presence of thermal radiation moving through a binary mixture embedded in a porous medium. The basic equations of motion including continuity, momentum, energy and concentration are simplified and solved analytically by using Homotopy Analysis Method (HAM). The energy and concentration fields are coupled with Dankohler and Schmidt numbers. By applying suitable transformation, the coupled nonlinear partial differential equations are converted to couple ordinary differential equations. The effect of physical parameters involved in the solutions of velocity, temperature and concentration profiles are discussed by assign numerical values and results obtained shows that the velocity, temperature and concentration profiles are influenced appreciably by the radiation parameter, Prandtl number, suction/injection parameter, reaction order index, solutal Grashof number and the thermal Grashof. It is observed that the non-Newtonian parameter H leads to an increase in the boundary layer thickness. It was established that the Prandtl number decreases thee thermal boundary layer thickness which helps in maintaining system temperature of the fluid flow. It is observed that the temperature profiles higher for heat source parameter and lower for heat sink parameter throughout the boundary layer. Fromm this simulation it is analyzed that an increase in the Schmidt number decreases the concentration boundary layer thickness. Additionally, for the sake of comparison numerical method (ND-Solve) and Adomian Decomposition Method are also applied and good agreement is found.

  11. Endovascular thrombectomy for M2 occlusions: comparison between forced arterial suction thrombectomy and stent retriever thrombectomy.

    Science.gov (United States)

    Kim, Yong-Won; Son, Seungnam; Kang, Dong-Hun; Hwang, Yang-Ha; Kim, Yong-Sun

    2017-07-01

    To date there has been no direct comparison of two frequently used endovascular thrombectomy (EVT) methods (forced arterial suction thrombectomy (FAST) and stent retriever thrombectomy) in M2 occlusions. We review our experiences with EVT performed using FAST and stent retriever thrombectomy in such cases. The subjects comprised 41 patients with an M2 occlusion who underwent EVT (25 with FAST, 16 with stent retriever thrombectomy). The patients' data were retrospectively analyzed to evaluate the technical characteristics and angiographic outcome of the two EVT techniques. Thrombolysis In Cerebral Infarction (TICI) grades 2b-3 using the first chosen technique did not differ significantly between the two techniques (FAST 64.0% vs stent retriever thrombectomy 81.2%, p=0.305). Time from groin puncture to reperfusion was significantly shorter for stent retriever thrombectomy (53.0 vs 38.5 min; p=0.045). Distal embolization occurred in three cases (12.0%) in the FAST group and in four (26.7%) in the stent retriever group (p=0.362). However, the two techniques did not differ significantly in the final TICI 2b-3 rate (72.0% vs 87.5%; p=0.441). A frequent angiographic finding regarding the failure of FAST was that the M2 occlusion was located immediately after severe acute angulation between M1 and M2. Stent retriever thrombectomy may provide faster reperfusion than FAST, while the FAST technique might be associated with lower distal embolization and a higher reperfusion rate for the first thrombectomy attempt, but without any significant difference in clinical outcome. When choosing the EVT method for M2 occlusions, consideration of the location of the occlusion and tortuosity between M1 and M2 might be helpful to achieve a better angiographic outcome. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  12. Randomized comparison of the i-gel™, the LMA Supreme™, and the Laryngeal Tube Suction-D using clinical and fibreoptic assessments in elective patients

    Directory of Open Access Journals (Sweden)

    Russo Sebastian G

    2012-08-01

    Full Text Available Abstract Background The i-gel™, LMA-Supreme (LMA-S and Laryngeal Tube Suction-D (LTS-D are single-use supraglottic airway devices with an inbuilt drainage channel. We compared them with regard to their position in situ as well as to clinical performance data during elective surgery. Methods Prospective, randomized, comparative study of three groups of 40 elective surgical patients each. Speed of insertion and success rates, leak pressures (LP at different cuff pressures, dynamic airway compliance, and signs of postoperative airway morbidity were recorded. Fibreoptic evaluation was used to determine the devices’ position in situ. Results Leak pressures were similar (i-gel™ 25.9, LMA-S 27.1, LTS-D 24.0 cmH2O; the latter two at 60 cmH2O cuff pressure as were insertion times (i-gel™ 10, LMA-S 11, LTS-D 14 sec. LP of the LMA-S was higher than that of the LTS-D at lower cuff pressures (p p p 0.05. Airway morbidity was more pronounced with the LTS-D (p 0.01. Conclusion All devices were suitable for ventilating the patients’ lungs during elective surgery. Trial registration German Clinical Trial Register DRKS00000760

  13. Soil-water characteristics of Gaomiaozi bentonite by vapour equilibrium technique

    Directory of Open Access Journals (Sweden)

    Wenjing Sun

    2014-02-01

    Full Text Available Soil-water characteristics of Gaomiaozi (GMZ Ca-bentonite at high suctions (3–287 MPa are measured by vapour equilibrium technique. The soil-water retention curve (SWRC of samples with the same initial compaction states is obtained in drying and wetting process. At high suctions, the hysteresis behaviour is not obvious in relationship between water content and suction, while the opposite holds between degree of saturation and suction. The suction variation can change its water retention behaviour and void ratio. Moreover, changes of void ratio can bring about changes in degree of saturation. Therefore, the total change in degree of saturation includes changes caused by suction and that by void ratio. In the space of degree of saturation and suction, the SWRC at constant void ratio shifts to the direction of higher suctions with decreasing void ratio. However, the relationship between water content and suction is less affected by changes of void ratio. The degree of saturation decreases approximately linearly with increasing void ratio at a constant suction. Moreover, the slope of the line decreases with increasing suction and they show an approximately linear relationship in semi-logarithmical scale. From this linear relationship, the variation of degree of saturation caused by the change in void ratio can be obtained. Correspondingly, SWRC at a constant void ratio can be determined from SWRC at different void ratios.

  14. Suction Buckets

    DEFF Research Database (Denmark)

    Feld, T.

    Friction Model, are implemented as user defined material models in the commercial finite element program ABAQUS. The simulated tests are partly pullout tests, subsequent cyclic loading, partly drained tests on buckets subject to vertical, horizontal and moment loading. The numerical analyses are capable...

  15. Effect of thermal radiation and chemical reaction on non-Newtonian fluid through a vertically stretching porous plate with uniform suction

    Directory of Open Access Journals (Sweden)

    Zeeshan Khan

    2018-06-01

    Full Text Available In this work, we discuss the unsteady flow of non-Newtonian fluid with the properties of heat source/sink in the presence of thermal radiation moving through a binary mixture embedded in a porous medium. The basic equations of motion including continuity, momentum, energy and concentration are simplified and solved analytically by using Homotopy Analysis Method (HAM. The energy and concentration fields are coupled with Dankohler and Schmidt numbers. By applying suitable transformation, the coupled nonlinear partial differential equations are converted to couple ordinary differential equations. The effect of physical parameters involved in the solutions of velocity, temperature and concentration profiles are discussed by assign numerical values and results obtained shows that the velocity, temperature and concentration profiles are influenced appreciably by the radiation parameter, Prandtl number, suction/injection parameter, reaction order index, solutal Grashof number and the thermal Grashof. It is observed that the non-Newtonian parameter H leads to an increase in the boundary layer thickness. It was established that the Prandtl number decreases thee thermal boundary layer thickness which helps in maintaining system temperature of the fluid flow. It is observed that the temperature profiles higher for heat source parameter and lower for heat sink parameter throughout the boundary layer. Fromm this simulation it is analyzed that an increase in the Schmidt number decreases the concentration boundary layer thickness. Additionally, for the sake of comparison numerical method (ND-Solve and Adomian Decomposition Method are also applied and good agreement is found. Keywords: Unsteady flow, Viscous fluid, Thermal radiation, Porous plate, Arrhenius kinetics, HAM and numerical method

  16. Swelling/shrinkage of compacted and natural clayey soils

    International Nuclear Information System (INIS)

    Nowamooz, H.

    2007-12-01

    This thesis presents an experimental study performed on compacted loose and natural dense expansive soils using osmotic odometers. Several successive cycles were applied under three different low constant vertical net stresses. The loose soil presents a significant shrinkage accumulation while the dense one produces the swelling accumulation during the suction cycles. The suction cycles induced an equilibrium stage which indicates an elastic behaviour of the samples. At the end of suction cycles, a loading/unloading test was performed at the constant suctions for both materials. The mechanical parameters, i.e. the virgin compression index lambda(s), the apparent pre-consolidation stress p0(s) and the elastic compression index values lambda are completely dependent on the followed stress paths. The whole experimental results made it possible to define the yielding surfaces: suction limit between micro and macrostructure (Lm/M), loading collapse (LC) and saturation curve (SCS). The suction limit (Lm/M) depends completely to the soil fabrics and to the diameter separating the micro- and macrostructure. The pre-consolidation stress variation with suction is represented by the LC surface. The compression curves at different imposed suctions converge towards the saturated state for the high applied vertical stresses. We consider the saturation pressure (Psat) as the necessary pressure to reach the saturated state for an imposed suction. The higher the suction, the higher the saturation pressure. The yielding surface representing this pressure as a function of suction is called the saturation curve (SCS). Generally we can state that the suction cycles unified the LC and SC surfaces and increased the (Lm/M) up to a higher value. (author)

  17. Results for the hybrid laminar flow control experiment conducted in the NASA Langley 8-foot transonic pressure tunnel on a 7-foot chord model

    Science.gov (United States)

    Bobbitt, Percy J.; Ferris, James C.; Harvey, William D.; Goradia, Suresh H.

    1992-01-01

    A description is given of the development of, and results from, the hybrid laminar flow control (HLFC) experiment conducted in the NASA LaRC 8 ft Transonic Pressure Tunnel on a 7 ft chord, 23 deg swept model. The methods/codes used to obtain the contours of the HLFC model surface and to define the suction requirements are outlined followed by a discussion of the model construction, suction system, instrumentation, and some example results from the wind tunnel tests. Included in the latter are the effects of Mach number, suction level, and the extent of suction. An assessment is also given of the effect of the wind tunnel environment on the suction requirements. The data show that, at or near the design Mach number, large extents of laminar flow can be achieved with suction mass flows over the first 25 percent, or less, of the chord. Top surface drag coefficients with suction extending from the near leading edge to 20 percent of the chord were approximately 40 percent lower than those obtained with no suction. The results indicate that HLFC can be designed for transonic speeds with lift and drag coefficients approaching those of LFC designs but with much smaller extents and levels of suction.

  18. Numerical Study of Piping Limits for Installation of Large Diameter Buckets in Layered Sand

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo; Thilsted, C.L.

    2010-01-01

    The bucket foundations, often referred as ‘suction caissons’, are large cylindrical structures, typically made in steel. The bucket foundations have the potential to be the cost-effective option for offshore wind turbines, if suction assisted penetration is employed. Suction installation may cause...... gradients developing in response to applied suction and the results are presented as simple closed form solutions useful for evaluation of suction thresholds against piping. These close form solutions are compared with large scale model test, performed in a natural seabed at a test site in Frederikshavn...

  19. Evaluation of the combination of radio frequency, infrared energy and mechanical rollers with suction to improve skin surface irregularities (cellulite) in a limited treatment area.

    Science.gov (United States)

    Kulick, Michael

    2006-12-01

    This IRB-approved (Institutional Review Board) study evaluated the efficacy of a device that combines radio frequency, infrared energy and mechanical rollers/suction (ELOS technology) to reduce skin surface irregularities in a limited treatment zone. Sixteen patients were enrolled and received two treatments per week for 4 consecutive weeks. Treatments were limited to a 20.53 cm x 33.02 cm area of the posterior or lateral thigh and lasted for 15 minutes. Maximum machine settings were used for all but one individual at every treatment. Evaluations consisted of a patient questionnaire and photographic assessment of skin contour by three physicians at 3 and 6 months after the last session who were blind to the treatment each patient received. Physician evaluators determined that all patients were improved at both post-treatment periods. The average improvement at 3 and 6 months was 62% and 50%, respectively. All patients felt they were improved. One patient described the treatment as painful and required reduced treatment parameters after the initial treatment. Bruising within the treatment area was observed in five patients following the initial sessions but this did not alter the treatment protocol and did not occur in subsequent treatments. One patient had a superficial skin burn due to poor electrode contact that did not require corrective treatment.

  20. EPA program to demonstrate mitigation measures for indoor radon: initial results

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1986-01-01

    EPA has installed radon mitigation techniques in 18 concrete block basement homes in the Reading Prong region of eastern Pennsylvania. Three alternative active soil ventilation approaches were tested: suction on the void network within the concrete block basement walls; suction on the footing drain tile system; and suction on the aggregate underneath the concrete slab. The initial 18 mitigation installations were designed to demonstrate techniques which would have low to moderate installation and operating costs. Where effective closure of major openings in the block walls is possible, suction on the wall voids has proved to be extremely effective, able to reduce homes having very high radon Working Levels (up to 7 WL) to 0.02 WL and less. However, where inaccessible major openings are concealed within the wall, it is more difficult and/or more expensive to develop adequate suction on the void network, and performance is reduced. Testing is continuing to demonstrate the steps required to achieve high performance with wall suction in homes with such difficult-to close walls. Drain tile suction can be very effective where the drain tiles completely surround the home; drain tile suction is the least expensive and most aesthetic of the active soil ventilation approaches, but appears susceptible to spikes in radon levels when the basement is depressurized. Sub-slab suction as tested in this study - with one or two individual suction points in the slab - does not appear adequate to ensure sustained high levels of reduction on block wall basement homes; it appears to effectively treat slab-related soil gas entry routes so long as a uniform layer of aggregate is present, but it does not appear to effectively treat the wall-related entry routes. Closure of major openings might have improved sub-slab suction performance. 5 figures, 3 tables

  1. Comparison of different soil water extraction systems for the prognoses of solute transport at the field scale using numerical simulations, field and lysimeter experiments

    Energy Technology Data Exchange (ETDEWEB)

    Weihermueller, L

    2005-07-01

    To date, the understanding of processes, factors, and interactions that influence the amount of extracted water and the solute composition sampled with suction cups is limited. But this information is required for process description of solute transport in natural soils. Improved system understanding can lead to a low cost and easy to install water sampling system which can help to predict solute transport in natural soils for the benefit of environmental protection. The main objectives of this work were to perform numerical simulations with different boundary conditions and to implement the findings in the interpretation of the lysimeter and field experiments. In a first part of this thesis, theoretical considerations on the processes affecting the spatial influence of a suction cup in soil and changes in solute transport initiated by the suction cups are presented, including testing and validation of available model and experimental approaches. In the second part, a detailed experimental study was conducted to obtain data for the comparison of the different soil water sampling systems. Finally, the numerical experiments of the suction cup influence were used for the interpretation of the experimental data. The main goals are summarized as follows: - Characterization of the suction cup activity domain (SCAD), suction cup extraction domain (SCED) and suction cup sampling area (SCSA) of active suction cups (definitions are given in Chapter 6). - Determination of the boundary conditions and soil properties [e.g. infiltration, applied suction, duration of water extraction, soil hydraulic properties and soil heterogeneity] affecting the activity domain, extraction domain and sampling area of a suction cup. - Identification of processes that change the travel time and travel time variance of solutes extracted by suction cups. - Validation of the numerically derived data with analytical and experimental data from literature. - Comparison of the experimental data obtained

  2. Method of controlling the operation of a feedwater system

    International Nuclear Information System (INIS)

    Takemaru, Koichi; Omori, Takashi.

    1975-01-01

    Object: At the time of pump trip at upstream, to maintain a good operating characteristic without stopping a pump at the downstream. Structure: In the event that one of pumps at the upstream (for example, a condenser pump) is tripped, interlock is activated to forcibly open a circulating valve for a condensation booster pump to partly return the flow rate of discharge to a pump suction part, thus preventing a decrease in suction pressure. In this case, in order to control suction pressure to a suitable level of pressure more than a net suction water head as required, a pressure adjusting meter for the condensation booster pump is provided on a pipe line on the side of suction so that the flow rate of circulation may be changed by the pressure adjusting valve to maintain the suction pressure in constant. (Kawakami, Y.)

  3. Teknik ved abortus provocatus, vabrasio og vakuumekstraktion. Klinisk afprøvning af Ambu Twin Pump 1000

    DEFF Research Database (Denmark)

    Krebs, L; Ingemanssen, Jens Lindgren; Jaszczak, P P

    1994-01-01

    Ambu Twin Pump 1000 is a suction pump designed for pharyngeal and tracheal suction in emergency situations. The pump can be operated by foot or by hand. The object of this test was to evaluate the applicability of the pump in performing legal abortion (before 13th. week), suction curettage...... and has sufficient suction capacity for the mentioned purposes. For induced abortion the pump was provided with a 200 ml reservoir for cleaning purposes....

  4. Modified swelling pressure apparatus using vapor pressure technique for compacted bentonite

    International Nuclear Information System (INIS)

    Nishimura, Tomoyoshi

    2012-01-01

    Document available in extended abstract form only. bentonite. The compacted bentonite is found in unsaturated conditions before applying of swelling due to absorption. The behaviour of compacted bentonite is not consistent with the principle and concepts of classical, saturated soil mechanics. An unsaturated soil theoretical framework using soil water characteristic curve has been fairly established over the past several decades. The soil-water characteristic curve is a relationship between soil moisture and soil suction obtained by the axis translation technique, vapor pressure technique or osmotic suction control which is a key feature in unsaturated soil mechanics. The soil-water characteristic curve can be used for prediction of the shear strength, volume change and hydraulic conductivity. Cui et al. 2002 indicated soil-water characteristic curve of expansive clay soil in high soil suction ranges using osmotic suction technique. Tripathy et al. 2010 described the soil-water characteristic curve both using the axis translation technique and vapor pressure technique in the entire soil suction ranges. Nishimura and Koseki 2011 measured suction of bentonite applied high soil suction due vapor pressure using a chilled mirror dew point potentiometer (WP4-T of DECAGON Device). The bentonite with gravimetric water content of 18 % indicated soil suction of 2.8 MPa at least. It is predicted that suction efforts to swelling pressure and shear strength of unsaturated compacted bentonite. This study focuses on the influence of suction on both swelling pressure and shear strength of compacted bentonite. The soil-water characteristic curve (SWCC) tests were conducted for compacted bentonite using both axis-translation technique and vapor pressure technique. The SWCC had a range from 0 kPa to 296 MPa in suction. The compacted bentonite having two different soil suctions were prepared for swelling pressure tests. Newly swelling pressure testing apparatus was developed in order

  5. An investigation on the supersonic ejectors working with mixture of air and steam

    International Nuclear Information System (INIS)

    Shafaee, Maziar; Tavakol, Mohsen; Riazi, Rouzbeh; Sharifi, Navid

    2015-01-01

    This study evaluated the performance of an ejector using two streams of fluids as suction flow. Three motive flow pressures were considered when investigating ejector performance; the suction flow pressure was assumed to be constant. The suction flow consisted of a mixture of air and steam and the mass fraction of air in this mixture varied from 0 to 1. The ejector performance curves were analyzed for different mass fractions of air. The results indicate that variation of the mass fraction of air in the suction flow mixture had a significant effect on ejector performance. At all motive flow pressures, the ejector entertainment ratio increased as the mass fraction of air in the suction flow increased. The results also show that the sensitivity of ejector performance to variation in the mass fraction of air in the suction flow decreases at higher motive flow pressures. An increase in motive flow pressure caused the transition from supersonic to subsonic flow to occur at higher ejector discharge pressures

  6. An investigation on the supersonic ejectors working with mixture of air and steam

    Energy Technology Data Exchange (ETDEWEB)

    Shafaee, Maziar; Tavakol, Mohsen; Riazi, Rouzbeh [University of Tehran, Tehran (Iran, Islamic Republic of); Sharifi, Navid [Amirkabir University of Technology, Tehran (Iran, Islamic Republic of)

    2015-11-15

    This study evaluated the performance of an ejector using two streams of fluids as suction flow. Three motive flow pressures were considered when investigating ejector performance; the suction flow pressure was assumed to be constant. The suction flow consisted of a mixture of air and steam and the mass fraction of air in this mixture varied from 0 to 1. The ejector performance curves were analyzed for different mass fractions of air. The results indicate that variation of the mass fraction of air in the suction flow mixture had a significant effect on ejector performance. At all motive flow pressures, the ejector entertainment ratio increased as the mass fraction of air in the suction flow increased. The results also show that the sensitivity of ejector performance to variation in the mass fraction of air in the suction flow decreases at higher motive flow pressures. An increase in motive flow pressure caused the transition from supersonic to subsonic flow to occur at higher ejector discharge pressures.

  7. Feeding of the megamouth shark (Pisces: Lamniformes: Megachasmidae) predicted by its hyoid arch: a biomechanical approach.

    Science.gov (United States)

    Tomita, Taketeru; Sato, Keiichi; Suda, Kenta; Kawauchi, Junro; Nakaya, Kazuhiro

    2011-05-01

    Studies of the megamouth shark, one of three planktivorous sharks, can provide information about their evolutionary history. Megamouth shark feeding has never been observed in life animals, but two alternative hypotheses on biomechanics suggest either feeding, i.e., ram feeding or suction feeding. In this study, the second moment of area of the ceratohyal cartilages, which is an indicator of the flexural stiffness of the cartilages, is calculated for 21 species of ram- and suction-feeding sharks using computed tomography. The results indicate that suction-feeding sharks have ceratohyal cartilages with a larger second moment of area than ram-feeding sharks. The result also indicates that the ram-suction index, which is an indicator of relative contribution of ram and suction behavior, is also correlated with the second moment of area of the ceratohyal. Considering that large bending stresses are expected to be applied to the ceratohyal cartilage during suction, the larger second moment of area of the ceratohyal of suction-feeding sharks can be interpreted as an adaptation for suction feeding. Based on the small second moment of area of the ceratohyal cartilage of the megamouth shark, the feeding mode of the megamouth shark is considered to be ram feeding, similar to the planktivorous basking shark. From these results, an evolutionary scenario of feeding mechanics of three species of planktivorous sharks can be suggested. In this scenario, the planktivorous whale shark evolved ram feeding from a benthic suction-feeding ancestor. Ram feeding in the planktivorous megamouth shark and the basking shark evolved from ram feeding swimming-type ancestors and that both developed their unique filtering system to capture small-sized prey. Copyright © 2011 Wiley-Liss, Inc.

  8. Airfoil

    Science.gov (United States)

    Ristau, Neil; Siden, Gunnar Leif

    2015-07-21

    An airfoil includes a leading edge, a trailing edge downstream from the leading edge, a pressure surface between the leading and trailing edges, and a suction surface between the leading and trailing edges and opposite the pressure surface. A first convex section on the suction surface decreases in curvature downstream from the leading edge, and a throat on the suction surface is downstream from the first convex section. A second convex section is on the suction surface downstream from the throat, and a first convex segment of the second convex section increases in curvature.

  9. An evaluation of the performance and optimization of a new wastewater treatment technology: the air suction flow-biofilm reactor.

    Science.gov (United States)

    Forde, P; Kennelly, C; Gerrity, S; Collins, G; Clifford, Eoghan

    2015-01-01

    In this laboratory study, a novel wastewater treatment technology, the air suction flow-biofilm reactor (ASF-BR) - a sequencing batch biofilm reactor technology with a passive aeration mechanism - was investigated for its efficiency in removing organic carbon, nitrogen and phosphorus, from high-strength synthetic wastewaters. A laboratory-scale ASF-BR comprising 2 reactors, 350 mm in diameter and 450 mm in height, was investigated over 2 studies (Studies 1 and 2) for a total of 430 days. Study 1 lasted a total of 166 days and involved a 9-step sequence alternating between aeration, anoxic treatment and settlement. The cycle time was 12.1 h and the reactors were operated at a substrate loading rate of 3.60 g filtered chemical oxygen demand (CODf)/m2 media/d, 0.28 g filtered total nitrogen (TNf)/m2 media/d, 0.24 g ammonium-nitrogen (NH4-N)/m2 media/d and 0.07 g ortho-phosphate (PO4-P)/m2 media/d. The average removal rates achieved during Study 1 were 98% CODf, 88% TNf, 97% NH4-N and 35% PO4-P. During Study 2 (264 days), the unit was operated at a loading rate of 2.49 g CODf/m2 media/d, 0.24 g TNf/m2 media/d, 0.20 g NH4-N/m2 media/d and 0.06 PO4-P/m2 media/d. The energy requirement during this study was reduced by modifying the treatment cycle in include fewer pumping cycles. Removal rates in Study 2 averaged 97% CODf, 86% TNf, 99% NH4-N and 76% PO4-P. The excess sludge production of the system was evaluated and detailed analyses of the treatment cycles were carried out. Biomass yields were estimated at 0.09 g SS/g CODf, removed and 0.21 g SS/g CODf, removed for Studies 1 and 2, respectively. Gene analysis showed that the use of a partial vacuum did not affect the growth of ammonia-oxidizing bacteria. The results indicate that the ASF-BR and passive aeration technologies can offer efficient alternatives to existing technologies.

  10. Prediction of the wetting-induced collapse behaviour using the soil-water characteristic curve

    Science.gov (United States)

    Xie, Wan-Li; Li, Ping; Vanapalli, Sai K.; Wang, Jia-Ding

    2018-01-01

    Collapsible soils go through three distinct phases in response to matric suction decrease during wetting: pre-collapse phase, collapse phase and post-collapse phase. It is reasonable and conservative to consider a strain path that includes a pre-collapse phase in which constant volume is maintained and a collapse phase that extends to the final matric suction to be experienced by collapsible soils during wetting. Upon this assumption, a method is proposed for predicting the collapse behaviour due to wetting. To use the proposed method, two parameters, critical suction and collapse rate, are required. The former is the suction value below which significant collapse deformations take place in response to matric suction decease, and the later is the rate at which void ratio reduces with matric suction in the collapse phase. The value of critical suction can be estimated from the water-entry value taking account of both the microstructure characteristics and collapse mechanism of fine-grained collapsible soils; the wetting soil-water characteristic curve thus can be used as a tool. Five sets of data of wetting tests on both compacted and natural collapsible soils reported in the literature were used to validate the proposed method. The critical suction values were estimated from the water-entry value with parameter a that is suggested to vary between 0.10 and 0.25 for compacted soils and to be lower for natural collapsible soils. The results of a field permeation test in collapsible loess soils were also used to validate the proposed method. The relatively good agreement between the measured and estimated collapse deformations suggests that the proposed method can provide reasonable prediction of the collapse behaviour due to wetting.

  11. Integrated axial and tangential serpentine cooling circuit in a turbine airfoil

    Science.gov (United States)

    Lee, Ching-Pang; Jiang, Nan; Marra, John J; Rudolph, Ronald J; Dalton, John P

    2015-05-05

    A continuous serpentine cooling circuit forming a progression of radial passages (44, 45, 46, 47A, 48A) between pressure and suction side walls (52, 54) in a MID region of a turbine airfoil (24). The circuit progresses first axially, then tangentially, ending in a last radial passage (48A) adjacent to the suction side (54) and not adjacent to the pressure side (52). The passages of the axial progression (44, 45, 46) may be adjacent to both the pressure and suction side walls of the airfoil. The next to last radial passage (47A) may be adjacent to the pressure side wall and not adjacent to the suction side wall. The last two radial passages (47A, 48A) may be longer along the pressure and suction side walls respectively than they are in a width direction, providing increased direct cooling surface area on the interiors of these hot walls.

  12. Water Retention Curves of Opalinus Clay

    International Nuclear Information System (INIS)

    Villar, M. V.; Romero, F. J.

    2012-01-01

    The water retention curve of Opalinus clay samples was determined under different conditions: total and matric suction, stress or no-stress conditions, wetting and drying paths. Through the fitting of these results to the van Genuchten expression the P parameter, related to the air entry value (AEV), was obtained. The AEV is the suction value above which air is able to enter the pores of the sample, and consequently, above which 2-phase flow can take place in the soil pore structure. The samples used in this research came from two different boreholes, BHT-1 and BHG-D1, but the behaviour of them did not depend on their location, what was probably due to the fact that both were drilled in the shay facies of the Opalinus clay. There was not a distinct difference between the results obtained under total or matric suctions. In the drying paths, both the water contents and the degrees of saturation tended to be higher when total suction was applied, however the reverse trend was observed for the water contents reached in wetting paths. As well, no clear difference was observed in the water retention curves obtained in odometers under matric and total suctions, what points to the osmotic component of suction in Opalinus clay not being significant. Overall, the water contents were lower and the degrees of saturation higher when suction was applied under vertical stress, what would indicate that the water retention capacity was lower under 8 MPa vertical stress than under free volume conditions. This vertical stress value is slightly higher than the maximum in situ stress. Also, the samples showed hysteresis according to the expected behaviour, i.e. the water contents for a given suction were higher during a drying path than during a wetting path. The P values obtained were between 6 and 34 MPa, and tended to be higher for the samples tested under stress, in drying paths and when total suction was used. The air entry value calculated from the mercury intrusion porosimetry

  13. Water Retention Curves of Opalinus Clay

    Energy Technology Data Exchange (ETDEWEB)

    Villar, M. V.; Romero, F. J.

    2012-11-01

    The water retention curve of Opalinus clay samples was determined under different conditions: total and matric suction, stress or no-stress conditions, wetting and drying paths. Through the fitting of these results to the van Genuchten expression the P parameter, related to the air entry value (AEV), was obtained. The AEV is the suction value above which air is able to enter the pores of the sample, and consequently, above which 2-phase flow can take place in the soil pore structure. The samples used in this research came from two different boreholes, BHT-1 and BHG-D1, but the behaviour of them did not depend on their location, what was probably due to the fact that both were drilled in the shay facies of the Opalinus clay. There was not a distinct difference between the results obtained under total or matric suctions. In the drying paths, both the water contents and the degrees of saturation tended to be higher when total suction was applied, however the reverse trend was observed for the water contents reached in wetting paths. As well, no clear difference was observed in the water retention curves obtained in odometers under matric and total suctions, what points to the osmotic component of suction in Opalinus clay not being significant. Overall, the water contents were lower and the degrees of saturation higher when suction was applied under vertical stress, what would indicate that the water retention capacity was lower under 8 MPa vertical stress than under free volume conditions. This vertical stress value is slightly higher than the maximum in situ stress. Also, the samples showed hysteresis according to the expected behaviour, i.e. the water contents for a given suction were higher during a drying path than during a wetting path. The P values obtained were between 6 and 34 MPa, and tended to be higher for the samples tested under stress, in drying paths and when total suction was used. The air entry value calculated from the mercury intrusion porosimetry

  14. On the Active and Passive Flow Separation Control Techniques over Airfoils

    Science.gov (United States)

    Moghaddam, Tohid; Banazadeh Neishabouri, Nafiseh

    2017-10-01

    In the present work, recent advances in the field of the active and passive flow separation control, particularly blowing and suction flow control techniques, applied on the common airfoils are briefly reviewed. This broad research area has remained the point of interest for many years as it is applicable to various applications. The suction and blowing flow control methods, among other methods, are more technically feasible and market ready techniques. It is well established that the uniform and/or oscillatory blowing and suction flow control mechanisms significantly improve the lift-to-drag ratio, and further, postpone the boundary layer separation as well as the stall. The oscillatory blowing and suction flow control, however, is more efficient compared to the uniform one. A wide range of parameters is involved in controlling the behavior of a blowing and/or suction flow control, including the location, length, and angle of the jet slots. The oscillation range of the jet slot is another substantial parameter.

  15. Effects of a trapped vortex cell on a thick wing airfoil

    Energy Technology Data Exchange (ETDEWEB)

    Lasagna, Davide; Iuso, Gaetano [Politecnico di Torino, Dipartimento di Ingegneria Aeronautica e Spaziale, Torino (Italy); Donelli, Raffaele; De Gregorio, Fabrizio [Centro Italiano di Ricerca Aerospaziale (C.I.R.A), Capua (Italy)

    2011-11-15

    The effects of a trapped vortex cell (TVC) on the aerodynamic performance of a NACA0024 wing model were investigated experimentally at Re = 10{sup 6} and 6.67 x 10{sup 5}. The static pressure distributions around the model and the wake velocity profiles were measured to obtain lift and drag coefficients, for both the clean airfoil and the controlled configurations. Suction was applied in the cavity region to stabilize the trapped vortex. For comparison, a classical boundary layer suction configuration was also tested. The drag coefficient curve of the TVC-controlled airfoil showed sharp discontinuities and bifurcative behavior, generating two drag modes. A strong influence of the angle of attack, the suction rate and the Reynolds number on the drag coefficient was observed. With respect to the clean airfoil, the control led to a drag reduction only if the suction was high enough. Compared to the classical boundary layer suction configuration, the drag reduction was higher for the same amount of suction only in a specific range of incidence, i.e., {alpha} = -2 to {alpha} = 6 and only for the higher Reynolds number. For all the other conditions, the classical boundary layer suction configuration gave better drag performances. Moderate increments of lift were observed for the TVC-controlled airfoil at low incidence, while a 20% lift enhancement was observed in the stall region with respect to the baseline. However, the same lift increments were also observed for the classical boundary layer suction configuration. Pressure fluctuation measurements in the cavity region suggested a very complex interaction of several flow features. The two drag modes were characterized by typical unsteady phenomena observed in rectangular cavity flows, namely the shear layer mode and the wake mode. (orig.)

  16. Development of High-Temperature Transport System for Molten Salt in Pyroprocessing

    International Nuclear Information System (INIS)

    Lee, Sung Ho; Kim, In Tae; Park, Sung Bin

    2014-01-01

    The electrorefining process, which is a key process in pyroprocessing, is composed of two parts, electrorefining to deposit a uranium with a solid cathode and electrowinning to co-deposit TRU and RE with a liquid cadmium cathode (LCC). As the electrorefining operation proceedes, TRU and RE are accumulated in electrolyte LiCl-KCl salt, and after the electrorefining process, the molten salt used in an electrorefining reactor should by transported to the next process, the electrowinning process, to recover U/TRU/RE; Thus, a molten salt transfer system by suction is now being developed. An apparatus for suction transport experiments was designed and constructed for the development of high- temperature molten salt transport technology. Suction transport experiments were performed using LiC-KCl eutectic salt. The feasibility of pyro-reprocessing has been demonstrated through many laboratory-scale experiments. In pyroprocessing, a eutectic LiCl-KCl salt was used as a liquid elextrolyte for a recovery of actinides. However, reliable transport technologies for these high temperature liquids have not yet been developed. A preliminary study on high-temperature transport technology for molten salt by suction is now being carried out. In this study, three different salt transport technologies (gravity, suction pump, and centrifugal pump) were investigated to select the most suitable method for molten salt transport. An apparatus for suction transport experiments was designed and installed for the development of high-temperature molten salt transport technology. Basic preliminary suction transport experiments were carried out using the prepared LiC-KCl eutectic salt at 500 .deg. C to observe the transport behavior of LiCl-KCl molten salt. In addition, a PRIDE salt transport system was designed and installed for an engineering-scale salt transport demonstration. Several types of suction transport experiments using molten salt (LiCl-KCl eutectics) for the development of a high

  17. Development of High-Temperature Transport System for Molten Salt in Pyroprocessing

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Ho; Kim, In Tae; Park, Sung Bin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    The electrorefining process, which is a key process in pyroprocessing, is composed of two parts, electrorefining to deposit a uranium with a solid cathode and electrowinning to co-deposit TRU and RE with a liquid cadmium cathode (LCC). As the electrorefining operation proceedes, TRU and RE are accumulated in electrolyte LiCl-KCl salt, and after the electrorefining process, the molten salt used in an electrorefining reactor should by transported to the next process, the electrowinning process, to recover U/TRU/RE; Thus, a molten salt transfer system by suction is now being developed. An apparatus for suction transport experiments was designed and constructed for the development of high- temperature molten salt transport technology. Suction transport experiments were performed using LiC-KCl eutectic salt. The feasibility of pyro-reprocessing has been demonstrated through many laboratory-scale experiments. In pyroprocessing, a eutectic LiCl-KCl salt was used as a liquid elextrolyte for a recovery of actinides. However, reliable transport technologies for these high temperature liquids have not yet been developed. A preliminary study on high-temperature transport technology for molten salt by suction is now being carried out. In this study, three different salt transport technologies (gravity, suction pump, and centrifugal pump) were investigated to select the most suitable method for molten salt transport. An apparatus for suction transport experiments was designed and installed for the development of high-temperature molten salt transport technology. Basic preliminary suction transport experiments were carried out using the prepared LiC-KCl eutectic salt at 500 .deg. C to observe the transport behavior of LiCl-KCl molten salt. In addition, a PRIDE salt transport system was designed and installed for an engineering-scale salt transport demonstration. Several types of suction transport experiments using molten salt (LiCl-KCl eutectics) for the development of a high

  18. Abortion - surgical

    Science.gov (United States)

    Suction curettage; Surgical abortion; Elective abortion - surgical; Therapeutic abortion - surgical ... Surgical abortion involves dilating the opening to the uterus (cervix) and placing a small suction tube into the uterus. ...

  19. 1,000 consecutive cases of laser-assisted liposuction and suction-assisted lipectomy managed with local anesthesia.

    Science.gov (United States)

    Chia, Christopher T; Theodorou, Spero J

    2012-08-01

    Advances in suction-assisted lipectomy (SAL) include improved instrumentation, better understanding of fluid dynamics, and an improved concept of appropriate indications. The tumescent technique uses subcutaneous injection of isotonic fluid containing vasoconstrictive and analgesic agents and is proved to be safe, with low morbidity and mortality rates. Laser-assisted liposuction (LAL) using local infiltration of an anesthetic and no general anesthesia or sedation has been developed, with claims of fat destruction and skin tightening. This study aimed to review 1,000 consecutive cases of LAL and SAL performed with the patient under local anesthesia and to determine whether this represents a safe technique with few complications. During a period of 22 months, 581 consecutive patients (486 females and 95 males) underwent 1,000 LAL/SAL operations, 545 of whom had multiple procedures performed. None of the patients had a body mass index (BMI) higher than 30 kg/m2. The patients ranged in age from 18 to 62 years. The fat aspirate ranged from 50 to 1,400 ml. Patients were given an oral sedative, an antibiotic, and an analgesic. Ringer's lactate solution containing lidocaine and epinephrine was injected into the subcutaneous space. The 1,064-nm and/or 1,320-nm neodymium:yttrium-aluminum-garnet (Nd:YAG) laser was used for laser lipolysis followed by SAL using standard and/or power-assisted liposuction (PAL) cannulas. The treated areas included the neck, triceps, male breast, midback, flanks, axilla, abdomen, mons pubis, thighs, presacrum, and knees. No patient was administered intravenous sedation or general anesthesia. The average number of areas treated was 1.8, and no major complications or mortalities were observed. There were three burns, two infections, one hematoma, and one seroma. A total of 73 secondary procedures were performed (7.3%). No tertiary procedures were required. For appropriately selected patients, comparable results can be obtained with an excellent

  20. Some results from the demonstration of indoor radon reduction measures in block basement houses. Report for June 1985-February 1987

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1987-03-01

    The paper gives results of tests of active soil-ventilation techniques in 24 block-wall basement houses in eastern Pennsylvania having significantly elevated indoor radon concentrations, generally above 740 Bq/cu m. The results indicate that radon levels can be reduced substantially (often below the U.S. EPA guideline of 148 Bq/cu m) if effective suction can be drawn on the soil underneath the concrete slabs of these houses. Such effective suction appears achievable when either: (a) the house has a complete loop of drain tile around its footings for water drainage purposes, and suction is drawn on that loop; or (b) a sufficient number of suction pipes can be inserted at the proper locations into the crushed rock or soil underneath the slab

  1. Some results from the demonstration of indoor radon reduction measures in block basement houses

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1989-01-01

    Active soil ventilation techniques have been tested in 26 block-wall basement houses in eastern Pennsylvania with significantly elevated indoor radon concentrations, generally above 740 Bq/m 3 , and the results indicate that radon levels can be reduced substantially often below the U.S. Environmental Protection Agency (EPA) guideline of 148 Bq/m 3 , if effective suction can be drawn on the soil underneath the concrete slabs of these houses. Such effective suction appears achievable when either: (1) the house has a complete loop of drain tile around its footings for water drainage purposes, and suction is drawn on that loop; or (2) a sufficient number of suction pipes can be inserted at the proper locations into the crushed rock or the soil underneath the slab

  2. Testing of indoor radon reduction techniques in eastern Pennsylvania: An update

    International Nuclear Information System (INIS)

    Henschel, D.B.; Scott, A.G.

    1987-01-01

    EPA has installed radon reduction measures in 38 houses in the Reading Prong region of eastern Pennsylvania. All were basement houses with hollow block or poured concrete foundation walls. The reduction approaches tested in most houses involved active soil ventilation, including: suction on the footing drain tile system; suction underneath the concrete slabs, using pipes inserted through the slabs from inside the house; and ventilation of the void network inside hollow block foundation walls. Heat recovery ventilators (HRVs) were tested in three houses. The current results confirm that, for the houses tested here, drain tile suction appears consistently able to provide high radon reductions when a complete loop of drain tile exists, often reducing high-radon houses to 4 pCi/l (148 B1/m 3 ) and less. Sub-slab suction (with pipes through the slab) can also provide high reductions if a sufficient number of suction pipes are located properly. Placement of one or more sub-slab suction pipes near each perimeter wall appears in this testing to aid in treating the major soil gas entry routes, although fewer pipes can sometimes give high reductions if conditions are favorable. For effective radon reduction using any active soil ventilation technique, it is important that major wall and slab openings be closed, and that a fan be employed that is capable of developing adequate static pressure

  3. Evaluation of a flexible bronchoscope prototype designed for bronchoscopy during mechanical ventilation: a proof-of-concept study.

    Science.gov (United States)

    Nay, M-A; Auvet, A; Mankikian, J; Herve, V; Dequin, P-F; Guillon, A

    2017-06-01

    Bronchoscopy during mechanical ventilation of patients' lungs significantly affects ventilation because of partial obstruction of the tracheal tube, and may thus be omitted in the most severely ill patients. It has not previously been possible to reduce the external diameter of the bronchoscope without reducing the diameter of the suction channel, thus reducing the suctioning capacity of the device. We believed that a better-designed bronchoscope could improve the safety of bronchoscopy in patients whose lungs were ventilated. We designed a flexible bronchoscope prototype with a drumstick-shaped head consisting of a long, thin proximal portion; a short and large distal portion for camera docking; and a large suction channel throughout the length of the device. The aims of our study were to test the impact of our prototype on mechanical ventilation when inserted into the tracheal tube, and to assess suctioning capacity. We first tested the efficiency of the suction channel, and demonstrated that the suction flow of the prototype was similar to that of conventional adult bronchoscopes. We next evaluated the consequences of bronchoscopy when using the prototype on minute ventilation and intrathoracic pressures during mechanical ventilation: firstly, in vitro using a breathing simulator; and secondly, in vivo using a porcine model of pulmonary ventilation. The insertion of adult bronchoscopes into the tracheal tube immediately impaired the protective ventilation strategy employed, whereas the prototype preserved it. For the first time, we have developed an innovative flexible bronchoscope designed for bronchoscopy during invasive mechanical ventilation, that both preserved the protective ventilation strategy, and enabled efficient suction flow. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  4. Plasmareaktor mit Prallstroemung zur Oberflaechenbehandlung

    OpenAIRE

    Elkine, B.; Mayer, J.; Oehr, C.

    1999-01-01

    The reactor includes a plasma treatment chamber (26), a gas distribution space, a gas suction space (29), and reaction gas entry and exit connections (7, 1). The gas distribution and suction spaces are separated from the gas treatment chamber by means of a flat structure (13) which is provided with inlets for gas from its distribution space into the treatment chamber, and outlets (19) for gas from the treatment chamber into the suction space. The gas distribution space and/or the plasma treat...

  5. Effects of thoracic squeezing on airway secretion removal in mechanically ventilated patients

    Directory of Open Access Journals (Sweden)

    Farkhondeh Yousefnia-Darzi

    2016-01-01

    Conclusions: According to the study findings, endotracheal suction with thoracic squeezing on expiration helps airway secretion discharge more than suction alone in patients on mechanical ventilators and can be used as an effective method.

  6. Suppression of vortex shedding around a square cylinder using ...

    Indian Academy of Sciences (India)

    control of vortex shedding of square cylinders using blowing or suction. ... also showed complete suppression of vortex shedding if suction velocity falls between 0.40 .... equations such that mass balance (continuity) is satisfied simultaneously.

  7. Trailing edge cooling using angled impingement on surface enhanced with cast chevron arrangements

    Science.gov (United States)

    Lee, Ching-Pang; Heneveld, Benjamin E.; Brown, Glenn E.; Klinger, Jill

    2015-05-26

    A gas turbine engine component, including: a pressure side (12) having an interior surface (34); a suction side (14) having an interior surface (36); a trailing edge portion (30); and a plurality of suction side and pressure side impingement orifices (24) disposed in the trailing edge portion (30). Each suction side impingement orifice is configured to direct an impingement jet (48) at an acute angle (52) onto a target area (60) that encompasses a tip (140) of a chevron (122) within a chevron arrangement (120) formed in the suction side interior surface. Each pressure side impingement orifice is configured to direct an impingement jet at an acute angle onto an elongated target area that encompasses a tip of a chevron within a chevron arrangement formed in the pressure side interior surface.

  8. Influence of Induced Magnetic Field on Free Convection of Nanofluid Considering Koo-Kleinstreuer-Li (KKL Correlation

    Directory of Open Access Journals (Sweden)

    M. Sheikholeslami

    2016-11-01

    Full Text Available In this paper, the influence of induced magnetic field on free convection of Al2O3-water nanofluid on permeable plate by means of Koo-Kleinstreuer-Li (KKL model is reported. Impact of Brownian motion, along with the properties of nanofluid, are also taken into account. The resulting equations are solved utilizing Runge-Kutta integration method. Obtained results are examined for innumerable energetic parameters, namely Al2O3 volume fraction, suction parameter, and Hartmann and magnetic Prandtl numbers. Results indicate that the velocity profile reduces with rise of the suction parameter and magnetic Prandtl and Hartmann numbers but it increases with addition of nanoparticles. Shear stress enhances with rise of suction parameter, magnetic Prandtl and Hartmann numbers. Temperature gradient improves with augment of suction parameter.

  9. Unsaturated soil moisture drying and wetting diffusion coefficient measurements in the laboratory.

    Science.gov (United States)

    2009-09-01

    ABSTRACTTransient moisture flow in an unsaturated soil in response to suction changes is controlled by the unsaturated moisture diffusion coefficient. The moisture diffusion coefficient can be determined by measuring suction profiles over time. The l...

  10. Large-eddy simulation of passive shock-wave/boundary-layer interaction control

    International Nuclear Information System (INIS)

    Pasquariello, Vito; Grilli, Muzio; Hickel, Stefan; Adams, Nikolaus A.

    2014-01-01

    Highlights: • The present study investigates a passive flow-control technique for shock-wave/boundary-layer interaction. • The control configuration consists of local suction and injection through a pressure feedback duct. • Implicit LES have been conducted for three different suction locations. • Suction reduces the size of the separation zone. • Turbulence amplification and reflected shock dynamics can be significantly reduced. - Abstract: We investigate a passive flow-control technique for the interaction of an oblique shock generated by an 8.8° wedge with a turbulent boundary-layer at a free-stream Mach number of Ma ∞ =2.3 and a Reynolds number based on the incoming boundary-layer thickness of Re δ 0 =60.5×10 3 by means of large-eddy simulation (LES). The compressible Navier–Stokes equations in conservative form are solved using the adaptive local deconvolution method (ALDM) for physically consistent subgrid scale modeling. Emphasis is placed on the correct description of turbulent inflow boundary conditions, which do not artificially force low-frequency periodic motion of the reflected shock. The control configuration combines suction inside the separation zone and blowing upstream of the interaction region by a pressure feedback through a duct embedded in the wall. We vary the suction location within the recirculation zone while the injection position is kept constant. Suction reduces the size of the separation zone with strongest effect when applied in the rear part of the separation bubble. The analysis of wall-pressure spectra reveals that all control configurations shift the high-energy low-frequency range to higher frequencies, while the energy level is significantly reduced only if suction acts in the rear part of the separated zone. In that case also turbulence production within the interaction region is significantly reduced as a consequence of mitigated reflected shock dynamics and near-wall flow acceleration

  11. Thermal-Hydraulic Performance of Scrubbing Nozzle Used for CFVS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Chul; Lee, Doo Yong; Jung, Woo Young; Lee, Jong Chan; Kim, Gyu Tae [FNC TECH, Yongin (Korea, Republic of)

    2016-05-15

    A Containment Filtered Venting System (CFVS) is the most interested device to mitigate a threat against containment integrity under the severe accident of nuclear power plant by venting with the filtration of the fission products. FNC technology and partners have been developed the self-priming scrubbing nozzle used for the CFVS which is based on the venturi effect. The thermal-hydraulic performances such as passive scrubbing water suction as well as pressure drop across the nozzle have been tested under various thermal-hydraulic conditions. The two types of test section have been built for testing the thermal-hydraulic performance of the self-priming scrubbing nozzle. Through the visualization loop, the liquid suction performance through the slit, pressure drop across the nozzle are measured. The passive water suction flow through the suction slit at the throat is important parameter to define the scrubbing performance of the self-priming scrubbing nozzle. The water suction flow is increased with the increase of the overhead water level at the same inlet gas flow. It is not so much changed with the change of inlet gas flow at the overhead water level.

  12. Rapid solidification of Ni{sub 50}Nb{sub 28}Zr{sub 22} glass former alloy through suction-casting; Solidificacao rapida da liga formadora de fase amorfa Ni{sub 50}Nb{sub 28}Zr{sub 22} atraves de fundicao em coquilha por succao

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, M.I.; Santos, F.S.; Bolfarini, C.; Botta Filho, W.J.; Kiminami, C.S., E-mail: issao16@gmail.co [Universidade Federal de Sao Carlos (DEMa/UFSCar), SP (Brazil). Dept. de Engenharia de Materiais

    2010-07-01

    To select new alloys with high glass forming ability (GFA) to present amorphous structure in millimeter scale, several semi-empirical models have been developed. In the present work, a new alloy, Ni{sub 50}Nb{sub 28}Zr{sub 22}d, was designed based on the combination of topological instability lambda (A) criterion and electronegativity difference ({Delta}e). The alloy was rapidly solidified in a bulk wedge sample by cooper mold suction casting in order to investigate its amorphization. The sample was characterized by the combination of scanning electron microscopy (MEV), X-ray diffraction (XRD) and differential scanning calorimeter (DSC). For the minimum thickness of 200 {mu}m analyzed, it was found that the alloy did not show a totally amorphous structure. Factor such as low cooling rate, existence of oxides on the surface of the elements and presence of oxygen in the atmosphere of equipment did not allowed the achievement of higher amorphous thickness. (author)

  13. Influence of effective stress on swelling pressure of expansive soils

    Directory of Open Access Journals (Sweden)

    Baille Wiebke

    2016-01-01

    Full Text Available The volume change and shear strength behaviour of soils are controlled by the effective stress. Recent advances in unsaturated soil mechanics have shown that the effective stress as applicable to unsaturated soils is equal to the difference between the externally applied stress and the suction stress. The latter can be established based on the soil-water characteristic curve (SWCC of the soil. In the present study, the evolution of swelling pressure in compacted bentonite-sand mixtures was investigated. Comparisons were made between magnitudes of applied suction, suction stress, and swelling pressure.

  14. Monitoring And Controlling Hydroponic Flow

    Science.gov (United States)

    Dreschel, Thomas W.

    1992-01-01

    Pressure-monitoring and -controlling apparatus maintains slight suction required on nutrient solution in apparatus described in "Tubular Membrane Plant-Growth Unit" (KSC-11375), while overcoming gravity effects on operation of system on Earth. Suction helps to hold solution in tubular membrane.

  15. The accuracy of acetylcholinesterase reaction in rectal suction biopsy in the diagnosis of Hirschsprung’s disease A acurácia da reação da acetilolinesterase na biópsia por sucção retal no diagnóstico da doença de Hirschsprung

    Directory of Open Access Journals (Sweden)

    Elizabeth S. Gugelmin

    2005-12-01

    Full Text Available Suction rectal biopsy with acetylcholinesterase (AChE histochemistry has been recognized as a reliable method for the diagnosis of Hirschsprung’s disease (HD. This study compares the final pathologic diagnosis made on paraffin embedded material of 68 colectomy specimens with the histochemical AChE reaction from the same patients previously diagnosed as HD by rectal suction biopsy at the Hospital Infantil Pequeno Príncipe (Curitiba, Brazil from 1988 to 1999. The group included 58 male and ten female patients with ages ranging from 7 days to 10 years. Thirty-six patients (52.94% where under 1 year of age at time of surgery. Two of the 68 patients had previous normal histochemical reactions for AChE: one of them resulted a normal ganglionic segment of bowel and the other one was a 15-day-old boy with total colonic aganglionosis, the only false-negative result in this series. Two patients had inconclusive results and because untreatable clinical symptoms also received surgical treatment. One of them resulted a normal ganglionic bowel and the other one was diagnosed as HD. All surgical specimens from the other 64 patients resulted in various extents of aganglionosis presenting prominent nerve trunks in the submucosal and myenteric plexuses, confirming the previous AChE histochemical diagnosis. In three cases there was total colonic aganglionosis. In this study the rectal suction biopsy associated with the histochemical method of AChE, performed days, months or sometimes years before surgery, resulted in a diagnostic accuracy rate of 95.59%, a positive predictive value of 100% and there were no false-positive results.A biópsia de reto por sucção associada à histoquímica enzimática pela acetilcolinesterase (AChE tem sido reconhecida como um método confiável para o diagnóstico da doença de Hirshsprung (HD. Este estudo compara o diagnóstico patológico final de 68 peças de colectomias incluídas em parafina com o diagnóstico prévio de HD

  16. LAMINAR STABILITY ANALYSIS IN BOUNDARY LAYER FLOW

    Directory of Open Access Journals (Sweden)

    Mihaela CALUDESCU

    2009-09-01

    Full Text Available This study presents a numerical study concerning the flow control by suction and injection. The case study is over a symmetrical airfoil with suction and injection slots. The angle of attack is 3 degree with the Mach number 0.12.

  17. Increased Levels of Type I and III Collagen and Hyaluronan in Scleroderma Skin

    DEFF Research Database (Denmark)

    Søndergaard, Klaus; Heickendorff, Lene; L, Risteli

    1997-01-01

    The aminoterminal propeptide of type III procollagen (PIIINP) and the carboxyterminal propeptide of type I procollagen (PICP) and hyaluronan (HA) were measured in plasma and suction blister fluid from 13 systemic sclerosis patients and 11 healthy volunteers. Suction blisters and skin biopsies were...

  18. Active Control of Flow Separation Over an Airfoil

    Science.gov (United States)

    Ravindran, S. S.

    1999-01-01

    Designing an aircraft without conventional control surfaces is of interest to aerospace community. In this direction, smart actuator devices such as synthetic jets have been proposed to provide aircraft maneuverability instead of control surfaces. In this article, a numerical study is performed to investigate the effects of unsteady suction and blowing on airfoils. The unsteady suction and blowing is introduced at the leading edge of the airfoil in the form of tangential jet. Numerical solutions are obtained using Reynolds-Averaged viscous compressible Navier-Stokes equations. Unsteady suction and blowing is investigated as a means of separation control to obtain lift on airfoils. The effect of blowing coefficients on lift and drag is investigated. The numerical simulations are compared with experiments from the Tel-Aviv University (TAU). These results indicate that unsteady suction and blowing can be used as a means of separation control to generate lift on airfoils.

  19. Comparación del dolor secundario a lipoaspiración tradicional versus lipolisis láser: Estudio prospectivo Postoperative pain in suction assited lipoplasty versus laser lipolisis: Comparative prospective study

    Directory of Open Access Journals (Sweden)

    S. Llanos Olmedo

    2007-12-01

    Full Text Available La lipoaspiración, técnica tradicional usada para el tratamiento de las lipodistrofias con cicatrices mínimas, ha sido a través de los años mejorada con los avances anestésicos, farmacológicos y de instrumental. A su vez han aparecido otras técnicas que han publicitado ventajas respecto al tiempo de recuperación, sintomatología y resultados estéticos. Una de estas técnicas es la laserlipolisis a la que se atribuye menos dolor, menos equimosis y rápido postoperatorio. No se encuentran trabajos que acrediten estas ventajas, por lo que decidimos estudiar si existen ventajas de laserlipolisis en comparación con la lipoaspiración tradicional respecto del dolor, síntoma importante a considerar en el postoperatorio. Para esto se diseñó un trabajo prospectivo randomizado con una muestra de 60 pacientes a los cuales se aplicaron las dos técnicas en diferentes áreas y al mismo paciente. Se evaluó el dolor con escala numérica analógica a las 4 horas, 48 horas y 5 días de postoperatorio. Los resultados mostraron que la laserlipolisis presenta menos dolor en los muslos medido a las 48 horas y 5 días de la intervención. No hay diferencias entre estas dos técnicas en las otras zonas medidas como abdomen, áreas pretrocantéreas ("alforjas", zona lumbar y pectoral. Considerando todos los pacientes sin diferenciar la técnica usada, las "alforjas" a las 4 horas duelen menos que el abdomen y a los 5 días duelen menos los muslos que el abdomen. No encontramos relación entre volumen aspirado e intensidad del dolor.The traditional suction-assisted lipoplasty, is a well established and commonly performed technique used for the treatment of lipodystrophias, which has undergone improvements with advances in anesthetics, pharmacology and introduction of new instruments. New techniques have appeared, promising advantages in recovery periods, symptomathology and aesthetic results when compared to the traditional suction-assisted lipoplasty

  20. Instability during Installation of Foundations for Offshore Structures

    DEFF Research Database (Denmark)

    Madsen, Søren; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    2012-01-01

    caisson”. During installation, suction is applied inside the bucket. The suction creates a pressure differential across the bucket lid, effectively increasing the downward force on the bucket while the water flow reduces the skirt tip resistance. The bucket foundation is constructed as a thin shell...

  1. Soluble intercellular adhesion molecule-1 (sICAM-1) and soluble interleukin-2 receptors (sIL-2R) in scleroderma skin

    DEFF Research Database (Denmark)

    Søndergaard, Klaus; Deleuran, Mette; Heickendorff, Lene

    1998-01-01

    In order to investigate whether soluble intercellular adhesion molecule-1 (sICAM-1) and soluble interleukin-2 receptors (sIL-2R) were present in scleroderma skin, and to compare their levels to concentrations measured in plasma and clinical parameters, we examined suction blister fluid and plasma...... from 13 patients with systemic sclerosis and 11 healthy volunteers. Suction blisters and biopsies were from the transition zone between normal skin and scleroderma, and uninvolved abdominal skin. The levels of sICAM-1 and sIL-2R were significantly increased in both plasma and suction blister fluid from...

  2. Study of modified two incisions silicone oil removal with a 23G transconjunctival sutureless vitrectomy system

    Directory of Open Access Journals (Sweden)

    Hai-Jun Yang

    2015-01-01

    Full Text Available AIM:To evaluate the efficacy and safety of silicone oil removal with a 23G transconjunctival sutureless vitrectomy system linked disposable transfusion tube and self-made suction tip. METHODS: The suction tip was made with a 23G infusion tube be cut from the end of the 5mm. It was used to connect the disposable transfusion tube and 23G puncture cannula. The disposable transfusion tube which was cut from the end of the MaiFei's pipe was connected with the effusion box of the vitreous cutter. Intraocular silicone oil was proactive suction and removed through two incisions on pars plana ciliaris with the vitreous cutter suction system. RESULTS: Only 13 cases(9.8%need suture puncture ports in 132 cases in the operation. Operation time was 7-28min. The average operation time was 15.1± 6.2min. In early postoperative, there were 107 cases(81.1%appeared lower intraocular pressure(CONCLUSION: The surgery that silicone oil is removed through two incisions with a 23G transconjunctival sutureless vitrectomy system linked disposable transfusion tube and self-made suction tip has the advantages of safe, effective, fast, economic, and it is worthy of popularization and application in clinical.

  3. Optimization analysis of the motor cooling method in semi-closed single screw refrigeration compressor

    Science.gov (United States)

    Wang, Z. L.; Shen, Y. F.; Wang, Z. B.; Wang, J.

    2017-08-01

    Semi-closed single screw refrigeration compressors (SSRC) are widely used in refrigeration and air conditioning systems owing to the advantages of simple structure, balanced forces on the rotor, high volumetric efficiency and so on. In semi-closed SSRCs, motor is often cooled by suction gas or injected refrigerant liquid. Motor cooling method will changes the suction gas temperature, this to a certain extent, is an important factor influencing the thermal dynamic performance of a compressor. Thus the effects of motor cooling method on the performance of the compressor must be studied. In this paper mathematical models of motor cooling process by using these two methods were established. Influences of motor cooling parameters such as suction gas temperature, suction gas quantity, temperature of the injected refrigerant liquid and quantity of the injected refrigerant liquid on the thermal dynamic performance of the compressor were analyzed. The performances of the compressor using these two kinds of motor cooling methods were compared. The motor cooling capacity of the injected refrigerant liquid is proved to be better than the suction gas. All analysis results obtained can be useful for optimum design of the motor cooling process to improve the efficiency and the energy efficiency of the compressor.

  4. Intermittent subglottic secretion drainage may cause tracheal damage in patients with few oropharyngeal secretions.

    Science.gov (United States)

    Suys, E; Nieboer, K; Stiers, W; De Regt, J; Huyghens, L; Spapen, H

    2013-12-01

    Injurious prolapse of tracheal mucosa into the suction port has been reported in up to 50% of intubated patients receiving continuous aspiration of subglottic secretions. We investigated whether similar injury could be inflicted by automated intermittent aspiration. Six consecutive patients, intubated with the Mallinckrodt TaperGuard Evac™ endotracheal tube, were studied. A flow sensor was placed between the vacuum regulating system and the mucus collector. Intermittent suctioning was performed at a pressure of -125 mmHg with a 25s interval and duration of 15s. After 24h, a CT scan of the tracheal region was performed. Excessive negative suction pressure, a fast drop in aspiration flow to zero, and important "swinging" movements of secretions in the evacuation line were observed in all patients. Oral instillation of antiseptic mouthwash restored normal aspiration flow and secretion mobility. CT imaging showed marked entrapment of tracheal mucosa into the suction port in all patients. In patients with few oropharyngeal secretions, automated intermittent subglottic aspiration may result in significant and potential harmful invagination of tracheal mucosa into the suction lumen. A critical amount of fluid must be present in the oropharynx to assure adequate and safe aspiration. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Influence of hydraulic hysteresis on the mechanical behavior of unsaturated soils and interfaces

    Science.gov (United States)

    Khoury, Charbel N.

    Unsaturated soils are commonly widespread around the world, especially at shallow depths from the surface. The mechanical behavior of this near surface soil is influenced by the seasonal variations such as rainfall or drought, which in turn may have a detrimental effect on many structures (e.g. retaining walls, shallow foundations, mechanically stabilized earth walls, soil slopes, and pavements) in contact with it. Thus, in order to better understand this behavior, it is crucial to study the complex relationship between soil moisture content and matric suction (a stress state variable defined as pore air pressure minus pore water pressure) known as the Soil Water Characteristic Curve (SWCC). In addition, the influence of hydraulic hysteresis on the behavior of unsaturated soils, soil-structure interaction (i.e. rough and smooth steel interfaces, soil-geotextile interfaces) and pavement subgrade (depicted herein mainly by resilient modulus, Mr) was also studied. To this end, suction-controlled direct shear tests were performed on soils, rough and smooth steel interfaces and geotextile interface under drying (D) and wetting after drying (DW). The shearing behavior is examined in terms of the two stress state variables, matric suction and net normal stress. Results along the D and DW paths indicated that peak shear strength increased with suction and net normal stress; while in general, the post peak shear strength was not influenced by suction for rough interfaces and no consistent trend was observed for soils and soil-geotextiles interfaces. Contrary to saturated soils, results during shearing at higher suction values (i.e. 25 kPa and above) showed a decrease in water content eventhough the sample exhibited dilation. A behavior postulated to be related to disruption of menisci and/or non-uniformity of pore size which results in an increase in localized pore water pressures. Interestingly, wetting after drying (DW) test results showed higher peak and post peak shear

  6. An Easy Method for Drainage of Fluid in Cases of Continuous Irrigation of the Hand

    Science.gov (United States)

    Makhijani, Sumeet

    2016-01-01

    Summary: Description of a novel method to perform continuous irrigation for flexor tenosynovitis in a way that is comfortable for the patient and convenient for nursing staff by placing the hand in the suction pouch of a lithotomy style drape attached to wall suction. PMID:28293498

  7. Four-wall turbine airfoil with thermal strain control for reduced cycle fatigue

    Science.gov (United States)

    Cambell, Christian X

    2013-09-17

    A turbine airfoil (20B) with a thermal expansion control mechanism that increases the airfoil camber (60, 61) under operational heating. The airfoil has four-wall geometry, including pressure side outer and inner walls (26, 28B), and suction side outer and inner walls (32, 34B). It has near-wall cooling channels (31F, 31A, 33F, 33A) between the outer and inner walls. A cooling fluid flow pattern (50C, 50W, 50H) in the airfoil causes the pressure side inner wall (28B) to increase in curvature under operational heating. The pressure side inner wall (28B) is thicker than walls (26, 34B) that oppose it in camber deformation, so it dominates them in collaboration with the suction side outer wall (32), and the airfoil camber increases. This reduces and relocates a maximum stress area (47) from the suction side outer wall (32) to the suction side inner wall (34B, 72) and the pressure side outer wall (26).

  8. Near-wall serpentine cooled turbine airfoil

    Science.gov (United States)

    Lee, Ching-Pang

    2013-09-17

    A serpentine coolant flow path (54A-54G) formed by inner walls (50, 52) in a cavity (49) between pressure and suction side walls (22, 24) of a turbine airfoil (20A). A coolant flow (58) enters (56) an end of the airfoil, flows into a span-wise channel (54A), then flows forward (54B) over the inner surface of the pressure side wall, then turns behind the leading edge (26), and flows back along a forward part of the suction side wall, then follows a loop (54E) forward and back around an inner wall (52), then flows along an intermediate part of the suction side wall, then flows into an aft channel (54G) between the pressure and suction side walls, then exits the trailing edge (28). This provides cooling matched to the heating topography of the airfoil, minimizes differential thermal expansion, revives the coolant, and minimizes the flow volume needed.

  9. A Comparison of Soil-Water Sampling Techniques

    Science.gov (United States)

    Tindall, J. A.; Figueroa-Johnson, M.; Friedel, M. J.

    2007-12-01

    The representativeness of soil pore water extracted by suction lysimeters in ground-water monitoring studies is a problem that often confounds interpretation of measured data. Current soil water sampling techniques cannot identify the soil volume from which a pore water sample is extracted, neither macroscopic, microscopic, or preferential flowpath. This research was undertaken to compare values of extracted suction lysimeters samples from intact soil cores with samples obtained by the direct extraction methods to determine what portion of soil pore water is sampled by each method. Intact soil cores (30 centimeter (cm) diameter by 40 cm height) were extracted from two different sites - a sandy soil near Altamonte Springs, Florida and a clayey soil near Centralia in Boone County, Missouri. Isotopically labeled water (O18? - analyzed by mass spectrometry) and bromide concentrations (KBr- - measured using ion chromatography) from water samples taken by suction lysimeters was compared with samples obtained by direct extraction methods of centrifugation and azeotropic distillation. Water samples collected by direct extraction were about 0.25 ? more negative (depleted) than that collected by suction lysimeter values from a sandy soil and about 2-7 ? more negative from a well structured clayey soil. Results indicate that the majority of soil water in well-structured soil is strongly bound to soil grain surfaces and is not easily sampled by suction lysimeters. In cases where a sufficient volume of water has passed through the soil profile and displaced previous pore water, suction lysimeters will collect a representative sample of soil pore water from the sampled depth interval. It is suggested that for stable isotope studies monitoring precipitation and soil water, suction lysimeter should be installed at shallow depths (10 cm). Samples should also be coordinated with precipitation events. The data also indicate that each extraction method be use to sample a different

  10. 78 FR 46532 - Airworthiness Directives; the Boeing Company Airplanes

    Science.gov (United States)

    2013-08-01

    ...-AWL-101, Engine Fuel Suction Feed Operational Test. (d) Subject Joint Aircraft System Component (JASC)/Air Transport Association (ATA) of America Code 2800, Aircraft Fuel System. (e) Unsafe Condition This... operational tests of the engine fuel suction feed of the fuel system, and other related testing if necessary...

  11. Density-dependent hydro-mechanical behaviour of a compacted expansive soil

    International Nuclear Information System (INIS)

    NOWAMOOZ, Hossein; MASROURI, Farimah

    2010-01-01

    Document available in extended abstract form only. Clayey soils are widely used in geotechnical engineering for dam cores, barriers in waste landfills and for engineered barriers in nuclear waste storage facilities. In the latter case, the used materials contain a large amount of smectite which is a highly swelling clay. On site, they can be submitted to complex suction/ stress/temperature variations that could change dramatically their hydro-mechanical behavior, meaning their saturated and unsaturated mechanical characteristics. To further our knowledge of the coupling between the hydraulic and mechanical behaviour of the swelling soils, this paper presents an experimental study on a swelling bentonite/silt mixture using osmotic odometers. A loading/unloading cycle was applied to samples with different initial dry densities (1.27, 1.48, and 1.55 Mg.m -3 ) at different constant suctions (0, 2, and 8 MPa). These experimental results provided a sufficient database to analytically model the mechanical behavior of the swelling soil and define three yielding surfaces: - the Suction Limit between Micro- and Macrostructure (s m/M ) and the Suction Limit between Nano- and Microstructure (s n/m ), which depend completely on the soil fabrics and the diameter separating the nano-, micro-, and macrostructure, - the Loading Collapse (LC) curve, representing the pre-consolidation stress variation as a function of suction, - the Saturation Curve (SC), representing the variation of the saturation stress (P sat ) as a function of suction. In general, we can state that the increase of compaction pressure unified the LC and SC surfaces and decreased the (s m/M ) value without modifying the (s n/m ) value. (authors)

  12. Study of the water retention and the consolidation of partially saturated soils in a thermo-hydro-mechanical framework

    International Nuclear Information System (INIS)

    Salager, Simon

    2007-01-01

    This work is concerned with the study of water retention and consolidation of unsaturated soils in a thermo-hydro-mechanical framework. It is organized into two parts which deal respectively with deformation and temperature effects on hydric behaviour, and suction and temperature effects on mechanical behaviour. In the first part, we point out the relevance of the characteristic surface concept for soils as opposed to the retention curve, which has limited modelling power in the case of deformable media. The characteristic surface concept is experimentally illustrated for the example of a clayey silty sand. Its modelling is based on a large sample of experimental investigations with about 240 measurements of the triplet void ratio, water content, suction. In addition, a thermo-hydric behaviour model is proposed in order to determine the characteristic surface and the retention curve for a given temperature. This model is validated for the case of two materials: a ceramic and a clayey silty sand through direct testing, and for other materials on the basis of an analysis of the literature. Finally, we present an application to the determination of the permeability of unsaturated soils taking into account deformation and temperature. In the second part, temperature and suction effects on the mechanical behaviour are studied through consolidation tests on 'Sion' silt. These tests are performed for different temperatures and suctions. For each test, swelling and compression indexes, as well as the pre-consolidation pressure are measured. The influence of temperature and suction on these essential parameters of mechanical behaviour is determined. Finally, we propose a theoretical model which account for pre-consolidation pressure as a function of temperature and suction. (author)

  13. Independently evolved upper jaw protrusion mechanisms show convergent hydrodynamic function in teleost fishes.

    Science.gov (United States)

    Staab, Katie Lynn; Holzman, Roi; Hernandez, L Patricia; Wainwright, Peter C

    2012-05-01

    A protrusible upper jaw has independently evolved multiple times within teleosts and has been implicated in the success of two groups in particular: Acanthomorpha and Cypriniformes. We use digital particle image velocimetry (DPIV) to compare suction feeding flow dynamics in a representative of each of these clades: goldfish and bluegill. Using DPIV, we contrast the spatial pattern of flow, the temporal relationship between flow and head kinematics, and the contribution of jaw protrusion to the forces exerted on prey. As expected, the spatial patterns of flow were similar in the two species. However, goldfish were slower to reach maximal kinematic excursions, and were more flexible in the relative timing of jaw protrusion, other jaw movements and suction flows. Goldfish were also able to sustain flow speeds for a prolonged period of time as compared with bluegill, in part because goldfish generate lower peak flow speeds. In both species, jaw protrusion increased the force exerted on the prey. However, slower jaw protrusion in goldfish resulted in less augmentation of suction forces. This difference in force exerted on prey corresponds with differences in trophic niches and feeding behavior of the two species. The bluegill uses powerful suction to capture insect larvae whereas the goldfish uses winnowing to sort through detritus and sediment. The kinethmoid of goldfish may permit jaw protrusion that is independent of lower jaw movement, which could explain the ability of goldfish to decouple suction flows (due to buccal expansion) from upper jaw protrusion. Nevertheless, our results show that jaw protrusion allows both species to augment the force exerted on prey, suggesting that this is a fundamental benefit of jaw protrusion to suction feeders.

  14. Basic life support trained nurses ventilate more efficiently with laryngeal mask supreme than with facemask or laryngeal tube suction-disposable--a prospective, randomized clinical trial.

    Science.gov (United States)

    Gruber, Elisabeth; Oberhammer, Rosmarie; Balkenhol, Karla; Strapazzon, Giacomo; Procter, Emily; Brugger, Hermann; Falk, Markus; Paal, Peter

    2014-04-01

    In some emergency situations resuscitation and ventilation may have to be performed by basic life support trained personnel, especially in rural areas where arrival of advanced life support teams can be delayed. The use of advanced airway devices such as endotracheal intubation has been deemphasized for basically-trained personnel, but it is unclear whether supraglottic airway devices are advisable over traditional mask-ventilation. In this prospective, randomized clinical single-centre trial we compared airway management and ventilation performed by nurses using facemask, laryngeal mask Supreme (LMA-S) and laryngeal tube suction-disposable (LTS-D). Basic life support trained nurses (n=20) received one-hour practical training with each device. ASA 1-2 patients scheduled for elective surgery were included (n=150). After induction of anaesthesia and neuromuscular block nurses had two 90-second attempts to manage the airway and ventilate the patient with volume-controlled ventilation. Ventilation failed in 34% of patients with facemask, 2% with LMA-S and 22% with LTS-D (P<0.001). In patients who could be ventilated successfully mean tidal volume was 240±210 ml with facemask, 470±120 ml with LMA-S and 470±140 ml with LTS-D (P<0.001). Leak pressure was lower with LMA-S (23.3±10.8 cm H2O, 95% CI 20.2-26.4) than with LTS-D (28.9±13.9 cm·H2O, 95% CI 24.4-33.4; P=0.047). After one hour of introductory training, nurses were able to use LMA-S more effectively than facemask and LTS-D. High ventilation failure rates with facemask and LTS-D may indicate that additional training is required to perform airway management adequately with these devices. High-level trials are needed to confirm these results in cardiac arrest patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Chest Tube Management after Surgery for Pneumothorax.

    Science.gov (United States)

    Pompili, Cecilia; Salati, Michele; Brunelli, Alessandro

    2017-02-01

    There is scant evidence on the management of chest tubes after surgery for pneumothorax. Most of the current knowledge is extrapolated from studies performed on subjects with lung cancer. This article reviews the existing literature with particular focus on the effect of suction and no suction on the duration of air leak after lung resection and surgery for pneumothorax. Moreover, the role of regulated suction, which seems to provide some benefit in reducing pneumothorax recurrence after bullectomy and pleurodesis, is discussed. Finally, a personal view on the management of chest tubes after surgery for pneumothorax is provided. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. PIV Measurements of Gas Flow Fields from Burning End

    Science.gov (United States)

    Huang, Yifei; Wu, Junzhang; Zeng, Jingsong; Tang, Darong; Du, Liang

    2017-12-01

    To study the influence of cigarette gas on the environment, it is necessary to know the cigarette gas flow fields from burning end. By using PIV technique, in order to reveal velocity characteristics of gas flow fields, the velocities of cigarette gas flow fields was analyzed with different stepping motor frequencies corresponding to suction pressures, and the trend of velocity has been given with image fitting. The results shows that the velocities of the burning end increased with suction pressures; Between velocities of the burning end and suction pressures, the relations present polynomial rule; The cigarette gas diffusion in combustion process is faster than in the smoldering process.

  17. Hydrodynamics of prey capture in sharks : effects of substrate

    NARCIS (Netherlands)

    Nauwelaerts, Sandra; Wilga, Cheryl; Sanford, Christopher; Lauder, George

    2007-01-01

    In suction feeding, a volume of water is drawn into the mouth of a predator. Previous studies of suction feeding in fishes have shown that significant fluid velocities are confined to a region within one mouth width from the mouth. Therefore, the predator must be relatively close to the prey to

  18. 78 FR 39571 - Airworthiness Directives; The Boeing Company Airplanes

    Science.gov (United States)

    2013-07-02

    ... service information.) UPS is concerned that the engine parameters monitored using Step 10 might have... system, followed by loss of fuel system suction feed capability on one engine, and in-flight shutdown of the engine. This AD requires repetitive operational tests of the engine fuel suction feed of the fuel...

  19. Micro-PIV (micro particle image velocimetry) visualization of red blood cells (RBCs) sucked by a female mosquito

    International Nuclear Information System (INIS)

    Kikuchi, K; Mochizuki, O

    2011-01-01

    A mosquito's pump is a highly effective system in the small suction domain. To understand a mosquito's blood suction mechanism, we analysed the characteristics of red blood cells (RBCs) in human blood during and after suction by a female mosquito. Focussing on the flow patterns of the RBCs in human blood being sucked by a mosquito, we visualized blood flow by using a micro-particle image velocimetry (μ-PIV) system, which combines an optical microscope and a PIV method. In an ex vivo experiment, a female mosquito was supplied diluted blood at the tip of the proboscis. We examined the blood flow around the tip of the proboscis and observed that RBCs were periodically sucked towards a hole around the tip. The sucked RBCs then homogeneously flowed parallel to the inner surface of the proboscis without adhering to the wall. Furthermore, using a bioelectric recording system, we directly measured electrical signals generated during suction by the pump muscles located in the mosquito's head. We found that the electrical signal power was synchronized with the acceleration of the RBCs in the sucking phase. A histological stain method was adapted for the observation of the form and internal structure of RBCs in the mosquito. Although the blood flow analysis revealed that the RBCs underwent shear stress during suction, RBCs in the mosquito's stomach maintained their original shape

  20. Placement of percutaneous transhepatic biliary stent using a silicone drain with channels

    Science.gov (United States)

    Yoshida, Hiroshi; Mamada, Yasuhiro; Taniai, Nobuhiko; Mineta, Sho; Mizuguchi, Yoshiaki; Kawano, Yoichi; Sasaki, Junpei; Nakamura, Yoshiharu; Aimoto, Takayuki; Tajiri, Takashi

    2009-01-01

    This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-Fr tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes one-step insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepatic biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy. PMID:19725159

  1. Impacto do sistema de aspiração traqueal aberto e fechado na incidência de pneumonia associada à ventilação mecânica: revisão de literatura Impact of the open and closed tracheal suctioning system on the incidence of mechanical ventilation associated pneumonia: literature review

    Directory of Open Access Journals (Sweden)

    Fernanda Maia Lopes

    2009-03-01

    Full Text Available A pneumonia é a infecção nosocomial mais comum em unidades de terapia intensiva, sendo a ventilação mecânica um fator fortemente associado ao seu desenvolvimento. O objetivo deste estudo foi descrever o impacto do sistema de aspiração traqueal aberto e fechado na incidência de pneumonia associada à ventilação mecânica. Realizou-se uma pesquisa na base de dados Pubmed para identificar tentativas controladas aleatórias, publicadas no período de 1990 a novembro de 2008. Nove estudos foram incluídos. Dos estudos revisados, sete não observaram redução significante da incidência de pneumonia associada à ventilação mecânica com o uso do sistema fechado comparado ao aberto, sendo que dois destes verificaram que o uso do sistema fechado resulta em incremento nas taxas de colonização sem incrementar sua incidência e um observou que o uso do sistema fechado não incrementa a colonização do trato respiratório e reduz a expansão de infecção resultando em redução nas taxas de sepse. Apenas dois estudos verificaram redução na incidência de pneumonia associada à ventilação mecânica com o uso do sistema fechado, e um destes revelou um risco 3.5 vezes maior de desenvolvimento desta infecção com o sistema aberto. Os resultados sugerem que o impacto do sistema de aspiração traqueal aberto e fechado é semelhante para o desenvolvimento da pneumonia associada à ventilação mecânica, assim a escolha do tipo de sistema de aspiração traqueal deve ser baseada em outros parâmetros. Entretanto, o sistema fechado aumenta o risco de colonização do trato respiratório, mas apresenta como vantagens a manutenção da ventilação mecânica e o menor prejuízo hemodinâmico.Pneumonia is the most common nosocominal infection in intensive care units and mechanical ventilation is a significant factor associated to its development. The objective of this study was to describe the impact of the open and closed tracheal suction

  2. 78 FR 14722 - Airworthiness Directives; The Boeing Company Airplanes

    Science.gov (United States)

    2013-03-07

    ... (JASC)/Air Transport Association (ATA) of America Code 2800, Aircraft Fuel System. (e) Unsafe Condition... repetitive operational tests of the engine fuel suction feed of the fuel system, and other related testing if... total loss of boost pump pressure of the fuel feed system, followed by loss of fuel system suction feed...

  3. 77 FR 41934 - Airworthiness Directives; The Boeing Company Airplanes

    Science.gov (United States)

    2012-07-17

    ... Transport Association (ATA) of America Code 2800, Aircraft Fuel System. (e) Unsafe Condition This AD was... operational tests of the engine fuel suction feed of the fuel system, and other related testing if necessary... loss of boost pump pressure of the fuel feed system, followed by loss of fuel system suction feed...

  4. 77 FR 40307 - Airworthiness Directives; The Boeing Company Airplanes

    Science.gov (United States)

    2012-07-09

    ... 2800, Aircraft Fuel System. (e) Unsafe Condition This AD was prompted by reports of two in-service... engine fuel suction feed of the fuel system, and other related testing if necessary. That NPRM was... pressure of the fuel feed system, followed by loss of fuel system suction feed capability on one engine...

  5. Management of Sudden Post-Operative Lung Collapse in Austere ...

    African Journals Online (AJOL)

    Due to lack of a bronchoscope, tracheostomy was done under local anaesthesia to facilitate a good and strong cough reflex, followed by bronchial suction and lavage. Thick mucus plug was extracted, saline lavage done by instilling 10ml into the tracheostomy and suction, with good cough reflex from the patient. This was ...

  6. Removing Boundary Layer by Suction

    Science.gov (United States)

    Ackeret, J

    1927-01-01

    Through the utilization of the "Magnus effect" on the Flettner rotor ship, the attention of the public has been directed to the underlying physical principle. It has been found that the Prandtl boundary-layer theory furnishes a satisfactory explanation of the observed phenomena. The present article deals with the prevention of this separation or detachment of the flow by drawing the boundary layer into the inside of a body through a slot or slots in its surface.

  7. Closed suction drain with bulb

    Science.gov (United States)

    ... of gloves. Put a new bandage around the drain tube site. Use surgical tape to hold it down ... small amount of redness is normal). There is drainage from the skin around the tube site. There is more tenderness and swelling at ...

  8. The paradox of negative pressure wound therapy--in vitro studies.

    Science.gov (United States)

    Kairinos, Nicolas; Solomons, Michael; Hudson, Donald A

    2010-01-01

    Negative-pressure wound therapy (NPWT) has revolutionised wound care. Yet, it is still not understood how hypobaric tissue pressure accelerates wound healing. There is very little reported on the relevant physics of any substance subjected to suction in this manner. The common assumption is that applying suction to a substance is likely to result in a reduction of pressure in that substance. Although more than 250 research articles have been published on NPWT, there are little data verifying whether suction increases or decreases the pressure of the substance it is applied to. Clarifying this basic question of physics is the first step in understanding the mechanism of action of these dressings. In this study, pressure changes were recorded in soft plasticene and processed meat, using an intracranial tissue pressure microsensor. Circumferential, non-circumferential and cavity NPWT dressings were applied, and pressure changes within the underlying substance were recorded at different suction pressures. Pressures were also measured at 1cm, 2 cm and 3 cm from the NPWT placed in a cavity. In all three types of NPWT dressings, the underlying substance pressure was increased (hyperbaric) as suction pressure increased. Although there was a substantial pressure increase at 1cm, the rise in pressure at the 2-cm and 3-cm intervals was minimal. Substance pressure beneath all types of NPWT dressing is hyperbaric in inanimate substances. Higher suction pressures generate greater substance pressures; however, the increased pressure rapidly dissipates as the distance from the dressing is increased. The findings of this study on inanimate objects suggest that we may need to review our current perception of the physics underlying NPWT dressings. Further research of this type on living tissues is warranted. Copyright (c) 2009 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Phase dependencies of the human baroreceptor reflex

    Science.gov (United States)

    Seidel, H.; Herzel, H.; Eckberg, D. L.

    1997-01-01

    We studied the influence of respiratory and cardiac phase on responses of the cardiac pacemaker to brief (0.35-s) increases of carotid baroreceptor afferent traffic provoked by neck suction in seven healthy young adult subjects. Cardiac responses to neck suction were measured indirectly from electrocardiographic changes of heart period. Our results show that it is possible to separate the influences of respiratory and cardiac phases at the onset of a neck suction impulse by a product of two factors: one depending only on the respiratory phase and one depending only on the cardiac phase. This result is consistent with the hypothesis that efferent vagal activity is a function of afferent baroreceptor activity, whereas respiratory neurons modulate that medullary throughput independent of the cardiac phase. Furthermore, we have shown that stimulus broadening and stimulus cropping influence the outcome of neck suction experiments in a way that makes it virtually impossible to obtain information on the phase dependency of the cardiac pacemaker's sensitivity to vagal stimulation without accurate knowledge of the functional shape of stimulus broadening.

  10. Low temperature distillation

    Energy Technology Data Exchange (ETDEWEB)

    Vandegrift, J N; Postel, C

    1929-04-09

    To recover gas, oil tars, and coked residues by low temperature distillation from bituminous coals, lignites, oil shales, and the like, the raw material is fed from a hopper into a rotary retort which is zonally heated, the temperature being greatest at the discharge end. The material is heated first to a relatively low temperature, thereby removing the moisture and lighter volatiles which are withdrawn through a pipe by the suction of a pump, while the higher boiling point volatiles and fixed gases are withdrawn by suction through an outlet from the higher temperature zone. The vapors withdrawn from the opposite ends of the retort pass through separate vapor lines and condensers, and the suction in each end of the retort, caused by the pumps, is controlled by valves, which also control the location of the neutral point in the retort formed by said suction. Air and inert gas may be introduced into the retort from pipe and stack respectively through a pipe, and steam may be admitted into the high temperature zone through a pipe.

  11. Secretion management in the mechanically ventilated patient.

    Science.gov (United States)

    Branson, Richard D

    2007-10-01

    Secretion management in the mechanically ventilated patient includes routine methods for maintaining mucociliary function, as well as techniques for secretion removal. Humidification, mobilization of the patient, and airway suctioning are all routine procedures for managing secretions in the ventilated patient. Early ambulation of the post-surgical patient and routine turning of the ventilated patient are common secretion-management techniques that have little supporting evidence of efficacy. Humidification is a standard of care and a requisite for secretion management. Both active and passive humidification can be used. The humidifier selected and the level of humidification required depend on the patient's condition and the expected duration of intubation. In patients with thick, copious secretions, heated humidification is superior to a heat and moisture exchanger. Airway suctioning is the most important secretion removal technique. Open-circuit and closed-circuit suctioning have similar efficacy. Instilling saline prior to suctioning, to thin the secretions or stimulate a cough, is not supported by the literature. Adequate humidification and as-needed suctioning are the foundation of secretion management in the mechanically ventilated patient. Intermittent therapy for secretion removal includes techniques either to simulate a cough, to mechanically loosen secretions, or both. Patient positioning for secretion drainage is also widely used. Percussion and postural drainage have been widely employed for mechanically ventilated patients but have not been shown to reduce ventilator-associated pneumonia or atelectasis. Manual hyperinflation and insufflation-exsufflation, which attempt to improve secretion removal by simulating a cough, have been described in mechanically ventilated patients, but neither has been studied sufficiently to support routine use. Continuous lateral rotation with a specialized bed reduces atelectasis in some patients, but has not been shown

  12. Evaluation of the incidence on insufficient cytology results comparing different ultrasound-guided aspiration techniques for thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Hyng; Park, Jun Hyun; Park, Ji Kang [Dept. of Radiology, Jeju National University Hospital, Jeju National University School of Medicine, Jeju (Korea, Republic of)

    2013-07-15

    We compared the incidence of insufficient thyroid cytology due to blood-stained materials or low cellularity in terms of aspiration technique, especially focusing on the degree of suction pressure and needle size. Three experienced radiologists performed ultrasound-guided aspiration for thyroid nodules in 1174 thyroid nodules consecutively. Three different techniques were used; (A) using a 25 gauge needle with mainly capillary technique in 269 nodules; (B) using a 25 gauge needle with 3 cc syringe and minimal suction pressure in 303 nodules; (C) using a 22-23 gauge needle with 10 cc syringe and aspirator in 602 nodules. The differences of the incidence of the insufficient cytology among the three aspiration techniques and relationships of the incidence and needle size/degree of suction pressure was statistically analyzed using the Mann-Whitney U test and the chi-square test with linear-by-linear association. Overall, the difference in insufficient cytology was significant across the three aspiration technique (p = 0.004), and the incidence tended to increase significantly with increase of needle size and degree of suction pressure (p < 0.001). A pairwise comparison of aspiration techniques found significant differences (p = 0.003) between techniques (A) and (C), and no differences between technique (B) and (C) (p 0.07) and between techniques (A) and (B) (p = 0.10). The incidence of insufficient cytology was significantly low in the capillary technique, and it increased significantly with the increase of needle size and degree of suction pressure.

  13. Evaluation of the incidence on insufficient cytology results comparing different ultrasound-guided aspiration techniques for thyroid nodules

    International Nuclear Information System (INIS)

    Kim, Seong Hyng; Park, Jun Hyun; Park, Ji Kang

    2013-01-01

    We compared the incidence of insufficient thyroid cytology due to blood-stained materials or low cellularity in terms of aspiration technique, especially focusing on the degree of suction pressure and needle size. Three experienced radiologists performed ultrasound-guided aspiration for thyroid nodules in 1174 thyroid nodules consecutively. Three different techniques were used; (A) using a 25 gauge needle with mainly capillary technique in 269 nodules; (B) using a 25 gauge needle with 3 cc syringe and minimal suction pressure in 303 nodules; (C) using a 22-23 gauge needle with 10 cc syringe and aspirator in 602 nodules. The differences of the incidence of the insufficient cytology among the three aspiration techniques and relationships of the incidence and needle size/degree of suction pressure was statistically analyzed using the Mann-Whitney U test and the chi-square test with linear-by-linear association. Overall, the difference in insufficient cytology was significant across the three aspiration technique (p = 0.004), and the incidence tended to increase significantly with increase of needle size and degree of suction pressure (p < 0.001). A pairwise comparison of aspiration techniques found significant differences (p = 0.003) between techniques (A) and (C), and no differences between technique (B) and (C) (p 0.07) and between techniques (A) and (B) (p = 0.10). The incidence of insufficient cytology was significantly low in the capillary technique, and it increased significantly with the increase of needle size and degree of suction pressure.

  14. Annual technical progress report inducer pump program government fiscal year 1976 and 1976T

    International Nuclear Information System (INIS)

    1976-01-01

    The Inducer Pump Program was initiated to demonstrate the applicability and advantages of an inducer pump to the LMFBR. The inducer is a pump blading which is specifically tailored to provide excellent suction performance. Operating suction specific speeds two to three times those for the inlet of a centrifugal impeller can be achieved with a properly and conservatively designed inducer. When coupled to a centrifugal impeller, the inducer offers excellent suction performance which can be effectively used to optimize pump efficiency, reduce pump size, and reduce pump cost. Four major efforts were undertaken during the five quarters of GFY 1976 to demonstrate and verify the inducer's suitability and applicability to LMFBR pumps, and to quantify the advantages of the inducer pump. The efforts are summarized

  15. Size does matter - Intraspecific variation of feeding mechanics in the crested newt Triturus dobrogicus (Kiritzescu, 1903)

    Science.gov (United States)

    Kucera, Florian; Beisser, Christian J.; Lemell, Patrick

    2018-03-01

    Many studies have yet been conducted on suction feeding in aquatic salamander species. Within the Salamandridae, the crested newt Triturus dobrogicus (Kiritzescu, 1903), occurring from the Austrian Danube floodplains to the Danube Delta, was not subject of investigations so far. The present study examines the kinematics of aquatic suction feeding in this species by means of high-speed videography. Recordings of five individuals of different size and sex while feeding on bloodworms were conducted, in order to identify potential discrepancies among individuals and sizes. Five coordinate points were digitized from recordings of prey capture and twelve time- and velocity-determined variables were evaluated. All specimens follow a typical inertial suction feeding process, where rapid hyoid depression expands the buccal cavity. Generated negative pressure within the buccal cavity causes influx of water along with the prey item into the mouth. Results demonstrate higher distance values and angles for gape in individuals with smaller size. In addition, hyoid depression is maximized in smaller individuals. While Triturus dobrogicus resembles a typical inertial suction feeder in its functional morphology, intraspecific differences could be found regarding the correlation of different feeding patterns and body size.

  16. Size does matter – Intraspecific variation of feeding mechanics in the crested newt Triturus dobrogicus (Kiritzescu, 1903

    Directory of Open Access Journals (Sweden)

    Kucera Florian

    2018-03-01

    Full Text Available Many studies have yet been conducted on suction feeding in aquatic salamander species. Within the Salamandridae, the crested newt Triturus dobrogicus (Kiritzescu, 1903, occurring from the Austrian Danube floodplains to the Danube Delta, was not subject of investigations so far. The present study examines the kinematics of aquatic suction feeding in this species by means of high-speed videography. Recordings of five individuals of different size and sex while feeding on bloodworms were conducted, in order to identify potential discrepancies among individuals and sizes. Five coordinate points were digitized from recordings of prey capture and twelve time- and velocity-determined variables were evaluated. All specimens follow a typical inertial suction feeding process, where rapid hyoid depression expands the buccal cavity. Generated negative pressure within the buccal cavity causes influx of water along with the prey item into the mouth. Results demonstrate higher distance values and angles for gape in individuals with smaller size. In addition, hyoid depression is maximized in smaller individuals. While Triturus dobrogicus resembles a typical inertial suction feeder in its functional morphology, intraspecific differences could be found regarding the correlation of different feeding patterns and body size.

  17. Exergy Analysis of the Revolving Vane Compressed Air Engine

    Directory of Open Access Journals (Sweden)

    Alison Subiantoro

    2016-01-01

    Full Text Available Exergy analysis was applied to a revolving vane compressed air engine. The engine had a swept volume of 30 cm3. At the benchmark conditions, the suction pressure was 8 bar, the discharge pressure was 1 bar, and the operating speed was 3,000 rev·min−1. It was found that the engine had a second-law efficiency of 29.6% at the benchmark conditions. The contributors of exergy loss were friction (49%, throttling (38%, heat transfer (12%, and fluid mixing (1%. A parametric study was also conducted. The parameters to be examined were suction reservoir pressure (4 to 12 bar, operating speed (2,400 to 3,600 rev·min−1, and rotational cylinder inertia (0.94 to 2.81 g·mm2. The study found that a higher suction reservoir pressure initially increased the second-law efficiency but then plateaued at about 30%. With a higher operating speed and a higher cylinder inertia, second-law efficiency decreased. As compared to suction pressure and operating speed, cylinder inertia is the most practical and significant to be modified.

  18. Numerical investigation of convective condensation with the presence of non-condensable gases in a vertical tube

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Wen [Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Li, Xiaowei, E-mail: lixiaowei@tsinghua.edu.cn [Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Wu, Xinxin [Key Laboratory of Advanced Reactor Engineering and Safety of Ministry of Education, Collaborative Innovation Center of Advanced Nuclear Energy Technology, Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing 100084 (China); Corradini, Michael L. [Department of Engineering Physics, University of Wisconsin-Madison, 1500 Engineering Drive, Madison, WI 53706 (United States)

    2016-02-15

    Highlights: • Gas mixture convective condensation in vertical tubes were simulated using FLUENT code. • The simulation results matched well with experimental data. • The detailed velocity field and species distribution were investigated. • The suction factors predicted by CFD models were compared with the classical correlations. • The effects of air and helium on steam condensation were compared. - Abstract: Steam condensation is degraded when non-condensable gases are present. Convective condensation of steam–air mixture and steam–helium mixture in vertical tubes were simulated using the CFD code FLUENT. The condensation process was modeled by defining source terms for the mass, momentum, species and energy conservation equations. Several cases with various steam mass fractions were simulated, the results matched well with the experimental data. Detailed velocity field and species distribution were investigated. The radial velocity was clearly represented, and the suction effect was modeled, which needs to be accounted for when using the heat and mass transfer analogy theory. The Nusselt and Sherwood numbers predicted by CFD models were compared with the classical correlations, and the suction effects were analyzed. The suction effect is proportional to steam mass fraction, while the suction factor is little affected by the Reynolds number. For forced convection flow in this work, the buoyant force can be neglected, so the larger diffusion coefficient of steam–helium mixture would improve the steam condensation compared to steam–air mixture. The condensation mass fluxes of steam–helium mixture and steam–air mixture are almost the same at relatively high steam inlet molar fraction (≥90%).

  19. Savannah River Site reactor hardware design modification study

    International Nuclear Information System (INIS)

    Fisher, J.E.

    1990-03-01

    A study was undertaken to assess the merits of proposed design modifications to the SRS reactors. The evaluation was based on the responses calculated by the RELAP5 systems code to double-ended guillotine break loss-of-coolant-accidents (DEGB LOCAs). The three concepts evaluated were (a) elevated plenum inlet piping with a guard vessel and clamshell enclosures, (b) closure of both rotovalves in the affected loop, and (c) closure of the pump suction valve in the affected loop. Each concept included a fast reactor shutdown (to 65% power in 100 ms) and a 2-s ac pump trip. For the elevated piping design, system recovery was predicted for breaks in the plenum inlet or pump suction piping; response to the pump discharge break location did not show improvement compared to the present system configuration. The rotovalve closure design improved system response to plenum inlet or pump discharge breaks; recovery was not predicted for pump suction breaks. The pump suction valve closure design demonstrated system recovery for all break locations downstream of the valve. A combination of features is recommended to ensure liquid inventory recovery for all break locations. The elevated piping design performance during pump discharge breaks would be improved with addition of a dc pump trip in the affected loop. Valve closure design performance for a break location in the short section of piping between the reactor concrete shield and the pump suction valve would benefit from the clamshell enclosing that section of piping. 12 refs., 10 figs., 2 tabs

  20. Performance and scaling of a novel locomotor structure: adhesive capacity of climbing gobiid fishes.

    Science.gov (United States)

    Maie, Takashi; Schoenfuss, Heiko L; Blob, Richard W

    2012-11-15

    Many species of gobiid fishes adhere to surfaces using a sucker formed from fusion of the pelvic fins. Juveniles of many amphidromous species use this pelvic sucker to scale waterfalls during migrations to upstream habitats after an oceanic larval phase. However, adults may still use suckers to re-scale waterfalls if displaced. If attachment force is proportional to sucker area and if growth of the sucker is isometric, then increases in the forces that climbing fish must resist might outpace adhesive capacity, causing climbing performance to decline through ontogeny. To test for such trends, we measured pressure differentials and adhesive suction forces generated by the pelvic sucker across wide size ranges in six goby species, including climbing and non-climbing taxa. Suction was achieved via two distinct growth strategies: (1) small suckers with isometric (or negatively allometric) scaling among climbing gobies and (2) large suckers with positively allometric growth in non-climbing gobies. Species using the first strategy show a high baseline of adhesive capacity that may aid climbing performance throughout ontogeny, with pressure differentials and suction forces much greater than expected if adhesion were a passive function of sucker area. In contrast, large suckers possessed by non-climbing species may help compensate for reduced pressure differentials, thereby producing suction sufficient to support body weight. Climbing Sicyopterus species also use oral suckers during climbing waterfalls, and these exhibited scaling patterns similar to those for pelvic suckers. However, oral suction force was considerably lower than that for pelvic suckers, reducing the ability for these fish to attach to substrates by the oral sucker alone.

  1. Avaliação técnica de um transportador pneumático de grãos por aspiração Technical evaluation of a suction pneumatic grain conveyor

    Directory of Open Access Journals (Sweden)

    Luís Antônio Bortolaia

    2008-04-01

    Full Text Available Este trabalho apresenta os resultados da avaliação técnica do protótipo do transportador pneumático de grãos por aspiração ASP 200. O equipamento foi construído para uso em instalações armazenadoras agrícolas, na limpeza de pés de elevadores, moegas e renovação do ar em galerias de silos. Os testes avaliaram características mecânicas do equipamento, descargas de material e ar, perdas de carga, vedação do equipamento, eficiência dos captores e o diâmetro das mangueiras. Os resultados subsidiaram diversas recomendações para melhoria no projeto do equipamento, que aumentarão a sua eficiência operacional. Embora o transporte pneumático seja considerado uma ciência experimental, os autores notaram a falta de procedimentos, parâmetros e orientações para testes e comparações na literatura, que são fundamentais para o desenvolvimento do projeto desses transportadores.This research shows the results that were obtained from technical evaluation of ASP 200 prototype that is a suction pneumatic grain conveyor. This equipment was built to use in agricultural storage facilities to clean bucket elevator feet, loading hoppers and air renovation in silo galleries. The tests have evaluated mechanical characteristics of conveyor, air and material discharges, pressure losses, air infiltration, intake nozzle efficiency and piping diameters. The results have allowed several recommendations to improve equipment design that will increase its operational efficiency. Although pneumatic conveying is considered an experimental science, the authors have perceived the lack of procedures, parameters and orientations to conduct tests and comparisons in literature, that are fundamental to develop a design of this conveyor type.

  2. Attraction to mammals of male mosquitoes with special reference to Aedes diantaeus in Sweden.

    Science.gov (United States)

    Jaenson, T G

    1985-06-01

    During investigations in central Sweden on the ecology of mosquito vectors of Ockelbo disease, large numbers of Aedes diantaeus males and lesser numbers of Ae. communis, Ae. excrucians and Ae. intrudens males were captured in animal-baited (rabbit, guinea pig, hen, dove, unbaited control) suction- and net-traps. In the five suction-traps, 57% of the diantaeus captured (N = 1,896) were males. Although the guinea pig-baited suction-trap captured the highest mean number of diantaeus males, data showed that these males, like the females, were mainly attracted to the largest mammal, i.e., the rabbit. These males assembled in the vicinity of the rabbit presumably to intercept females coming to feed. The net-trap data showed that orientation by the males to the rabbit presumably involved olfactory cues emanating from the mammal.

  3. Glass forming ability and magnetic properties of Co(40.2−x)Fe(20.1+x)Ni6.7B22.7Si5.3Nb5 (x=0–10) bulk metallic glasses produced by suction casting

    International Nuclear Information System (INIS)

    Sarlar, Kagan; Kucuk, Ilker

    2015-01-01

    The effect of Fe concentration on the glass forming ability (GFA) and magnetic properties in Co (40.2−x) Fe (20.1+x) Ni 6.7 B 22.7 Si 5.3 Nb 5 (x=0–10) bulk metallic glasses were investigated. By suction casting method, the bulk metallic glasses with diameters up to 2 mm were produced. We try to find out which Fe concentration makes an influence on Co based system's magnetic properties and glass forming ability. The curves of thermal analysis, obtained using differential scanning calorimetry (DSC), show that the Co (40.2−x) Fe (20.1+x) Ni 6.7 B 22.7 Si 5.3 Nb 5 (x=0–10) have a supercooled liquid region (∆T x ) of about 44 K. The saturation magnetizations (J s ) for as-cast BMG alloys were in the range of 0.62 T−0.81 T. - Highlights: • The effect of Fe concentration on the glass forming ability. • The substitution of an appropriate amount of Fe can enhance the GFA. • The substitution of Fe for Co also improves soft magnetic properties of the BMGs. • The high of J s 0.62−0.81 T with a low H c of 2−289 A/m of the alloys

  4. Aerodynamic effects in isotope separation by gaseous diffusion

    International Nuclear Information System (INIS)

    Bert, L.A.; Prosperetti, A.; Fiocchi, R.

    1978-01-01

    The turbulent flow of an isotopic mixture in a porous-walled pipe is considered in the presence of suction through the wall. A simple model is formulated for the evaluation of aerodynamic effects on the separation efficiency. The predictions of the model are found to compare very favourably with experiment. In the limit of small suction velocities, results obtained by other investigators for diffusion in a turbulent steam are recovered. (author)

  5. Experimental Study on Noise Characteristic of Centrifugal Compressor Surge

    OpenAIRE

    Yang, Qichao; Zhao, Yuanyang; SHU, Yue; LI, Xiaosa; LI, Liansheng

    2016-01-01

    The centrifugal air compressor test rig is was designed and established. The experimental study was carried out on the surge characteristics of centrifugal compressor including the pressure in the pipe and the noise characteristics under different rotation speed. The tested results showed that both the suction pressure and discharge pressure fluctuation increase under surge condition and the amplitude of discharge pressure fluctuation is significantly higher than that of suction pressure. In ...

  6. Laser cutting system

    Science.gov (United States)

    Dougherty, Thomas J

    2015-03-03

    A workpiece cutting apparatus includes a laser source, a first suction system, and a first finger configured to guide a workpiece as it moves past the laser source. The first finger includes a first end provided adjacent a point where a laser from the laser source cuts the workpiece, and the first end of the first finger includes an aperture in fluid communication with the first suction system.

  7. An Experimental Study on Active Flow Control Using Synthetic Jet Actuators over S809 Airfoil

    International Nuclear Information System (INIS)

    Gul, M; Uzol, O; Akmandor, I S

    2014-01-01

    This study investigates the effect of periodic excitation from individually controlled synthetic jet actuators on the dynamics of the flow within the separation and re-attachment regions of the boundary layer over the suction surface of a 2D model wing that has S809 airfoil profile. Experiments are performed in METUWIND's C3 open-loop suction type wind tunnel that has a 1 m × 1 m cross-section test section. The synthetic jet array on the wing consists of three individually controlled actuators driven by piezoelectric diaphragms located at 28% chord location near the mid-span of the wing. In the first part of the study, surface pressure, Constant Temperature Anemometry (CTA) and Particle Image Velocimetry (PIV) measurements are performed over the suction surface of the airfoil to determine the size and characteristics of the separated shear layer and the re-attachment region, i.e. the laminar separation bubble, at 2.3x10 5 Reynolds number at zero angle of attack and with no flow control as a baseline case. For the controlled case, CTA measurements are carried out under the same inlet conditions at various streamwise locations along the suction surface of the airfoil to investigate the effect of the synthetic jet on the boundary layer properties. During the controlled case experiments, the synthetic jet actuators are driven with a sinusoidal frequency of 1.45 kHz and 300Vp-p. Results of this study show that periodic excitation from the synthetic jet actuators eliminates the laminar separation bubble formed over the suction surface of the airfoil at 2.3x10 5 Reynolds number at zero angle of attack

  8. Water retention properties of stiff silt

    Directory of Open Access Journals (Sweden)

    Barbara Likar

    2017-06-01

    Full Text Available Recent research into the behaviour of soils has shown that it is in fact much more complex than can be described by the mechanics of saturated soils. Nowadays the trend of investigations has shifted towards the unsaturated state. Despite the signifiant progress that has been made so far, there are still a lot of unanswered questions related to the behaviour of unsaturated soils. For this reason, in the fild of geotechnics some new concepts are developed, which include the study of soil suction. Most research into soil suction has involved clayey and silty material, whereas up until recently no data have been available about measurements in very stiff preconsolidated sandy silt. Very stiff preconsolidated sandy silt is typical of the Krško Basin, where it is planned that some very important geotechnical structures will be built, so that knowledge about the behaviour of such soils at increased or decreased water content is essential. Several different methods can be used for soil suction measurements. In the paper the results of measurements carried out on very stiff preconsolidated sandy silt in a Bishop - Wesley double-walled triaxial cell are presented and compared with the results of soil suction measurements performed by means of a potentiometer (WP4C. All the measurement results were evaluated taking into account already known results given in the literature, using the three most commonly used mathematical models. Until now a lot of papers dealing with suction measurements in normal consolidated and preconsolidated clay have been published. Measurements on very stiff preconsolidated sandy silt, as presented in this paper were not supported before.

  9. A low-hemolysis blood aspirator conserves blood during surgery.

    Science.gov (United States)

    Clague, C T; Blackshear, P L

    1995-01-01

    Blood damage caused by traditional vacuum-operated suction tubes, particularly when air is aspirated along with the blood, usually exceeds damage from all other components. In addition to platelet injury, there is a high degree of hemolysis, which leads to high plasma hemoglobin levels and reduces the number of red blood cells available for reinfusion during cases of blood conservation, such as autologous transfusion and cardiac bypass. This work was undertaken to minimize hemolysis, and the accompanying platelet destruction, during aspiration, with the design of a jet-driven aspirator that separates and removes air from blood immediately within the suction tip. The jet-driven aspirator can suction blood at a range of rates from 100 to at least 700 ml/min, separates and removes 80-100% of aspirated air, operates at any orientation, and generates subatmospheric pressures on the order of only 1 inch H2O. In-vitro hemolysis testing showed a significant reduction in average plasma hemoglobin release, from 19.4 mg/dl to 1.8 mg/dl, when air was removed during blood aspiration. In comparative testing with a conventional vacuum suction tube, the jet-driven aspirator showed significantly less hemolysis than the conventional aspirator at comparable rates of air and blood aspiration.

  10. Nanocrystallization in Cu-Zr-Al-Sm Bulk Metallic Glasses

    Science.gov (United States)

    Sikan, Fatih; Yasar, Bengisu; Kalay, Ilkay

    2018-04-01

    The effect of rare-earth element (Sm) microalloying on the thermal stability and crystallization kinetics of melt-spun ribbons and suction-cast rods of Zr48Cu38.4Al9.6Sm4 alloy were investigated using differential scanning calorimetry (DSC), X-ray diffraction (XRD), transmission electron microscopy (TEM), and atom probe tomography (APT). The XRD results of constant heating rate annealing indicated that amorphous Zr48Cu38.4Al9.6Sm4 melt-spun ribbons devitrifies into Cu2Sm at 673 K (400 °C). The sequence continues with the precipitation of Cu10Zr7 and then these two phases coexist. XRD and TEM studies on 1 mm diameter as suction-cast rods indicated the precipitation of 30-nm-mean size Cu2Sm crystals during solidification. TEM investigation of the isothermal crystallization sequence of melt-spun ribbons and 1-mm-diameter suction-cast rods revealed the precipitation of Cu2Sm nanocrystals at the onset of crystallization and the restriction of the growth of these nanocrystals up to 10 nm diameter with further annealing. APT analysis of 1-mm-diameter suction-cast rods showed that the limited growth of Cu2Sm nanocrystals is due to sluggish diffusion of Sm and Al-Zr pile up at the interface.

  11. Thermal performance analysis of reciprocating compressor with stepless capacity control system

    International Nuclear Information System (INIS)

    Bin, Tang; Yuanyang, Zhao; Liansheng, Li; Guangbin, Liu; Le, Wang; Qichao, Yang; Haiping, Xu; Feng, Zhu; Wenhui, Meng

    2013-01-01

    On the basic principle of stepless capacity control system for large reciprocating compressor, the thermal cycle was analyzed. The equations for the process of suction, reverse flow, compression, discharge and expansion of clearance gas were established. According to these equations, p–V diagrams at various situations were simulated. An experimental platform was setup and the compressor with designed stepless capacity control system run well. The experimental results show that the capacity of compressor can be regulated steplessly, and the motor power is reduced proportionally with respect to the reduction of capacity. During the suction process, both the flow resistance of valve and the pressure fluctuation in cylinder can be reduced by opening the suction valves with the actuators. The simulated and experimental results showed good coincidence. The clearance volume and valve clearance Mach number had a negative influence on the thermal performance of compressor with stepless capacity control system. -- Highlights: ► Flow resistance of valve can be reduced and pressure fluctuation can be reduced. ► Equivalent Mach number of reverse flow is much higher than that of suction process. ► Response of stepless capacity control system is important for regulation accuracy. ► Clearance and valve clearance Mach number have influence on thermal performance

  12. 18th national meeting for energy saving promotion (prize winning case awarded by Ministry of International Trade and Industry). ; Development of air cooling equipment for gas turbine combustion. Dai 18 kai sho energy suishin zenkoku taikai (tsusho sangyo daijinsho jusho jirei). ; Gas turbine nenshoyo kuki reikyaku sochi no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    1993-01-30

    This paper describes a development of air cooling equipment for gas turbine combustion in a 1090-MW combined plant and a discussion on its cooling effect. An open-type gas turbine reduces its output when suction temperature rises. This is a characteristic for a combined plant with high heat efficiency not capable of exhibiting its ability in summer. As a result of testing cooling methods, water spraying nozzles utilizing latent evaporation heat of water were installed at a gas turbine suction opening. Effects of cooling the gas turbine combustion air resulted in reducing the gas turbine suction temperature by 1.8[degree]C as a result of water spray at an ambient temperature of 30[degree]C and a relative humidity of 60%, increasing the plant output by 12 MW as a result of cooling the suction air, and improving the heat efficiency by about 0.035%. The amount of ammonia used for reducing nitrogen oxide generation was reduced by 10.8 kg/hr. Under an assumption of experimenting the water spray in summer on a 15-hour per day basis for 50 days, a calculation indicates an annual economic effect of about 13.5 million yen. 8 figs., 8 tabs.

  13. Assessment of Risk Factors of Intrauterine Adhesions in Patients With Induced Abortion and the Curative Effect of Hysteroscopic Surgery.

    Science.gov (United States)

    Mo, Xiaoliang; Qin, Guirong; Zhou, Zhoulin; Jiang, Xiaoli

    2017-10-03

    To explore the risk factors for intrauterine adhesions in patients with artificial abortion and clinical efficacy of hysteroscopic dissection. 1500 patients undergoing artificial abortion between January 2014 and June 2015 were enrolled into this study. The patients were divided into two groups with or without intrauterine adhesions. Univariate and Multiple logistic regression were conducted to assess the effects of multiple factors on the development of intrauterine adhesions following induced abortion. The incidence rate for intrauterine adhesions following induced abortion is 17.0%. Univariate showed that preoperative inflammation, multiple pregnancies and suction evacuation time are the influence risk factors of intrauterine adhesions. Multiple logistic regression demonstrates that multiple pregnancies, high intrauterine negative pressure, and long suction evacuation time are independent risk factors for the development of intrauterine adhesions following induced abortion. Additionally, intrauterine adhesions were observed in 105 mild, 80 moderate, and 70 severe cases. The cure rates for these three categories of intrauterine adhesions by hysteroscopic surgery were 100.0%, 93.8%, and 85.7%, respectively. Multiple pregnancies, high negative pressure suction evacuation and long suction evacuation time are independent risk factors for the development of intrauterine adhesions following induced abortions. Hysteroscopic surgery substantially improves the clinical outcomes of intrauterine adhesions.

  14. Field measurements of groundwater pollution from agricultural land use

    International Nuclear Information System (INIS)

    Cepuder, P.

    2000-01-01

    This study was carried out in a problem area located to the northeast of Vienna. Several devices were installed for collecting water samples from the soil profile to measure nitrate concentration: suction cups, soil-water samplers, tensiometers and small lysimeters. Measurements of N leaching from four levels of fertilizer application were made at Gross Enzersdorf under irrigated wheat using suction cups and lysimeters. In order to determine fertilizer-N uptake by plants and the amounts retained in the soil and leached, 15 N-enriched fertilizer was applied to micro-plots. The nitrate concentrations below the root zone were measured for winter wheat followed by a cover crop, using suction cups. Soil-water contents were measured in the soil profile with a neutron probe and gypsum blocks, and suctions were measured with tensiometers at four depths. The yields of crops together with total N in grain and straw from fertilizer and soil were calculated. Also presented are data on the mineralization, immobilization and actual fertilizer used by the crops. Winter wheat took up between 27% and 44% of the applied fertilizer. The storage of fertilizer N in soil ranged between 22% and 36%, and only a small fraction was leached. (author)

  15. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  16. Dual function of the pectoral girdle for feeding and locomotion in white-spotted bamboo sharks.

    Science.gov (United States)

    Camp, Ariel L; Scott, Bradley; Brainerd, Elizabeth L; Wilga, Cheryl D

    2017-07-26

    Positioned at the intersection of the head, body and forelimb, the pectoral girdle has the potential to function in both feeding and locomotor behaviours-although the latter has been studied far more. In ray-finned fishes, the pectoral girdle attaches directly to the skull and is retracted during suction feeding, enabling the ventral body muscles to power rapid mouth expansion. However, in sharks, the pectoral girdle is displaced caudally and entirely separate from the skull (as in tetrapods), raising the question of whether it is mobile during suction feeding and contributing to suction expansion. We measured three-dimensional kinematics of the pectoral girdle in white-spotted bamboo sharks during suction feeding with X-ray reconstruction of moving morphology, and found the pectoral girdle consistently retracted about 11° by rotating caudoventrally about the dorsal scapular processes. This motion occurred mostly after peak gape, so it likely contributed more to accelerating captured prey through the oral cavity and pharynx, than to prey capture as in ray-finned fishes. Our results emphasize the multiple roles of the pectoral girdle in feeding and locomotion, both of which should be considered in studying the functional and evolutionary morphology of this structure. © 2017 The Author(s).

  17. The suitability of EIT to estimate EELV in a clinical trial compared to oxygen wash-in/wash-out technique.

    Science.gov (United States)

    Karsten, Jan; Meier, Torsten; Iblher, Peter; Schindler, Angela; Paarmann, Hauke; Heinze, Hermann

    2014-02-01

    Open endotracheal suctioning procedure (OSP) and recruitment manoeuvre (RM) are known to induce severe alterations of end-expiratory lung volume (EELV). We hypothesised that EIT lung volumes lack clinical validity. We studied the suitability of EIT to estimate EELV compared to oxygen wash-in/wash-out technique. Fifty-four postoperative cardiac surgery patients were enrolled and received standardized ventilation and OSP. Patients were randomized into two groups receiving either RM after suctioning (group RM) or no RM (group NRM). Measurements were conducted at the following time points: Baseline (T1), after suctioning (T2), after RM or NRM (T3), and 15 and 30 min after T3 (T4 and T5). We measured EELV using the oxygen wash-in/wash-out technique (EELVO2) and computed EELV from EIT (EELVEIT) by the following formula: EELVEITTx,y…=EELVO2+ΔEELI×VT/ΔZ. EELVEIT values were compared with EELVO2 using Bland-Altman analysis and Pearson correlation. Limits of agreement ranged from -0.83 to 1.31 l. Pearson correlation revealed significant results. There was no significant impact of RM or NRM on EELVO2-EELVEIT relationship (p=0.21; p=0.23). During typical routine respiratory manoeuvres like endotracheal suctioning or alveolar recruitment, EELV cannot be estimated by EIT with reasonable accuracy.

  18. Investigation of seepage around the bucket skirt during installation in sand

    DEFF Research Database (Denmark)

    Koteras, Aleksandra Katarzyna; Ibsen, Lars Bo

    or along bucket skirt with known soil condition, bucket geometry and applied suction. The second aim of the study is to evaluate expressions for normalized seepage length, s/h, for different soil combinations and penetration depths. The seepage length is then 7 used to make a prediction of critical...... pressure that will create piping channels at exit, which is near to seabed and to the caisson wall, along bucket wall and at the tip. That is how the limits for suction installation can be assumed. Finally, the critical suction is used for predicting the reduction of penetration resistance and the method...... describing this approach is presented in the report with its assumptions. The method is called AAU CPT-based method and it is a great step in the development of practical design tool for bucket foundation installation process....

  19. Radon reduction in crawl-space houses

    International Nuclear Information System (INIS)

    Osborne, M.C.; Moore, D.G.; Southerlan, R.E.; Brennan, T.; Pyle, B.E.

    1989-01-01

    This paper gives results of an EPA study of radon-mitigation alternatives for crawl space houses in several houses in Nashville, TN. Application of one of these alternative mitigation options, suction under a polyethylene membrane, has been successful in significantly reducing radon levels in both the crawl space and the house. The large radon concentrations measured under unvented plastic ground covers and the moisture barriers found in many crawl spaces can act as radon-rich reservoirs capable of contaminating a crawl space and house during periods of depressurization. With the exhaust components of the mitigation system in place, radon levels below the plastic decreased by more than 95% under both passive and active suction conditions. Based on the study, the design of a cost-effective subplastic suction passive radon mitigation system for crawl spaces seems promising

  20. Remote surface testing and inspection vehicle

    International Nuclear Information System (INIS)

    Hyde, E.A.; Goldsmith, H.A.; Proudlove, M.J.

    1981-01-01

    A remotely controlled vehicle capable of roving over the outer surface of a nuclear reactor primary vessel carrying inspection instrumentation. The vehicle comprises an elongate bridge having a pair of suction support pads. Each pad carries gas thrusters for acting in opposition to the suction effort thereby to reduce adherence of the pads and enable displacement of the vehicle over the surface. The vehicle is supported by a services conducting umbilical. (author)

  1. Novel Radon Sub-Slab Suctioning System

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2013-01-01

    A new principle for radon protection is currently presented which makes use of a system of horizontal pressurised air ducts located within the lower part of the rigid insulation layer of the ground-floor slab. The function of this system is based on the principles of pressure reduction within...... a grid of horizontal air ducts with low pressure which are able to remove air and radon from the ground. Results showed the system to be effective in preventing radon infiltrating from the ground through the ground-floor slab, avoiding high concentrations of radon being accumulated inside houses....... For the system to be effective, the pressure within the ducts must be lower than the pressure inside the house. The new principle was shown to be effective in preventing radon from polluting the indoor air by introducing low pressure in the horizontal grid of air ducts. A lower pressure than the pressure inside...

  2. Development and validation of mechanical model for saturated/unsaturated bentonite buffer

    International Nuclear Information System (INIS)

    Yamamoto, S.; Komine, H.; Kato, S.

    2010-01-01

    Document available in extended abstract form only. Development and validation of mechanical models for bentonite buffer and backfill materials are one of important subjects to appropriately evaluate long term behaviour or condition of the EBS in radioactive waste disposal. The Barcelona Basic Model (BBM), which is one of extensions of the modified Cam-Clay model for unsaturated and expansive soil, has been developed and widely applied to several problems by using the coupled THM code, Code B right. Advantage of the model is that mechanical characteristics of buffer and backfill materials under not only saturated condition but also unsaturated one are taken account as well as swelling characteristics due to wetting. In this study the BBM is compared with already existing experimental data and already developed another model in terms of swelling characteristics of Japanese bentonite Kunigel-V1, and is validated in terms of consolidation characteristics based on newly performed controlled-suction oedometer tests for the Kunigel-V1 bentonite. Komine et al. (2003) have proposed a model (set of equations) for predicting swelling characteristics based on the diffuse double layer concept and the van der Waals force concept etc. They performed a lot of swelling deformation tests of bentonite and sand-bentonite mixture to confirm the applicability of the model. The BBM well agrees with the model proposed by Komine et al. and the experimental data in terms of swelling characteristics. Compression index and swelling index depending on suction are introduced in the BBM. Controlled-suction consolidation tests (oedometer tests) were performed to confirm the applicability of the suction dependent indexes to unsaturated bentonite. Compacted bentonite with initial dry density of 1.0 Mg/m 3 was tested. Constant suction, 80 kPa, 280 kPa and 480 kPa was applied and kept during the consolidation tests. Applicability of the BBM to consolidation and swelling behaviour of saturated and

  3. A acurácia da reação da acetilolinesterase na biópsia por sucção retal no diagnóstico da doença de Hirschsprung

    OpenAIRE

    Gugelmin, Elizabeth S.; Torres, Luiz Fernando B.

    2005-01-01

    Suction rectal biopsy with acetylcholinesterase (AChE) histochemistry has been recognized as a reliable method for the diagnosis of Hirschsprung’s disease (HD). This study compares the final pathologic diagnosis made on paraffin embedded material of 68 colectomy specimens with the histochemical AChE reaction from the same patients previously diagnosed as HD by rectal suction biopsy at the Hospital Infantil Pequeno Príncipe (Curitiba, Brazil) from 1988 to 1999. The group included 58 male and t...

  4. Gas turbine

    International Nuclear Information System (INIS)

    Yang, Ok Ryong

    2004-01-01

    This book introduces gas turbine cycle explaining general thing of gas turbine, full gas turbine cycle, Ericson cycle and Brayton cycle, practical gas turbine cycle without pressure loss, multiaxial type gas turbine cycle and special gas turbine cycle, application of basic theory on a study on suction-cooling gas turbine cycle with turbo-refrigerating machine using the bleed air, and general performance characteristics of the suction-cooling gas turbine cycle combined with absorption-type refrigerating machine.

  5. Incorporation of sweep in a transonic fan design using a 3D blade-row geometry package intended for aero-structural-manufacturing optimization

    OpenAIRE

    Abdelhamid, Hazen Fahmy

    1997-01-01

    Approved for public release; distribution is unlimited A new 3D blade row geometry package was developed and implemented. In the new representation the blade is described by six Bezier surfaces two of which represent the pressure and suction surfaces with sixteen points each. The leading and trailing edges are each represented by two Bezier surfaces. Only one extra parameter is required (in addition to the pressure and suction surfaces parameters) to define each of the leading and trailing...

  6. On the development a pneumatic four-legged mechanism autonomous vertical wall climbing robot

    International Nuclear Information System (INIS)

    Mohamad Shukri Zainal Abidin; Shamsudin H.M. Amin . shukri@suria.fke.utm.my

    1999-01-01

    The paper describes the design of a prototype legged mechanism together with suction mechanism, the mechanical design, on-board controller and an initial performance test. The design is implemented in the form of a pneumatically powered multi-legged robot equipped with suction pads at the sole of the feet for wall climbing purpose. The whole mechanism and suction system is controlled by controller which is housed on-board the robot. The gait of the motion depended on the logic control patterns as dictated by the controller. The robot is equipped with sensors both at the front and rear ends that function as an obstacle avoidance facility. Once objects are detected, signals are sent to the controller to start an evasive action that is to move in the opposite direction. The mechanism has been tested and initial results have shown promising potential for an autonomous mobile. (Author)

  7. Cooled airfoil in a turbine engine

    Science.gov (United States)

    Vitt, Paul H; Kemp, David A; Lee, Ching-Pang; Marra, John J

    2015-04-21

    An airfoil in a gas turbine engine includes an outer wall and an inner wall. The outer wall includes a leading edge, a trailing edge opposed from the leading edge in a chordal direction, a pressure side, and a suction side. The inner wall is coupled to the outer wall at a single chordal location and includes portions spaced from the pressure and suction sides of the outer wall so as to form first and second gaps between the inner wall and the respective pressure and suction sides. The inner wall defines a chamber therein and includes openings that provide fluid communication between the respective gaps and the chamber. The gaps receive cooling fluid that provides cooling to the outer wall as it flows through the gaps. The cooling fluid, after traversing at least substantial portions of the gaps, passes into the chamber through the openings in the inner wall.

  8. Analisa Performansi Sistem Air Conditioning Mobil tipe ET 450 dengan Variasi Tekanan Kerja Kompresor

    Directory of Open Access Journals (Sweden)

    Adi Purnawan

    2012-11-01

    Full Text Available Comfort and coolness when traveling by vehicle especially car is highly needed. So many attempts have been made byhumans that comfortable traveling by car can be achieved. One of the effective ways in which comfortable traveling by car can beobtained is by installing air conditioning. The performance of air conditioning system is highly influenced by how the compressorworks. In other words, the pressure resulting from the suction highly determines the performance of air conditioning system,which then affects how the compressor works, the compressor power, the refrigeration effect, the efficiency of isentropic andcoefficient of performance (COP of the car air conditioning sytem especially that of the car air conditioner type ET 450. Fromwhat has been described above, the writer would like to conduct a research entiled “ Analysis of the Performance of the Car AirConditioning system Type ET 450 with Variation of the Compressor Pressure”.The test was conducted on the car air conditioner type ET 450 with variations of suction 2.8 bar, 3 bar, 3.2 bar, 3.4bar, 3.6 bar and 3.8 bar. The data were obtained from the pressure of compressor output (P2, the temperatures in each point areT1, T2, T3, T4, the compressor rotationn is n, the strength of electrical current is I, and the volumetric flow rate. The data werethen processed and analyzed so that so that the performance of each variation of the suction could be actually and theoreticallyobtained.The findings show that the bigger the suction, the bigger the performance of the car air conditioner type ET 450 wouldbe. The theoretical coefficient of performance (COP produced was bigger than the actual COP. The optimal COP took placewhen the suction was 441.325 kPa, the actual COP was 3.513177 and the theoretical COP was 3.632062

  9. Physiological effects of a single chest physiotherapy session in mechanically ventilated and extubated preterm neonates.

    Science.gov (United States)

    Mehta, Y; Shetye, J; Nanavati, R; Mehta, A

    2016-01-01

    To assess the changes on various physiological cardio-respiratory parameters with a single chest physiotherapy session in mechanically ventilated and extubated preterm neonates with respiratory distress syndrome. This is a prospective observational study in a neonatal intensive care unit setting. Sixty preterm neonates with respiratory distress syndrome, thirty mechanically ventilated and thirty extubated preterm neonates requiring chest physiotherapy were enrolled in the study. Parameters like heart rate (HR), respiratory rate (RR), Silverman Anderson score (SA score in extubated), oxygen saturation (SpO2) and auscultation findings were noted just before, immediately after chest physiotherapy but before suctioning, immediately after suctioning and after 5 minutes of the session. The mean age of neonates was 9.55±5.86 days and mean birth weight was 1550±511.5 g. As there was no significant difference in the change in parameters on intergroup comparison, further analysis was done considering two groups together (n = 60) except for SA score. As SA score was measured only in extubated neonates. HR did not change significantly during chest physiotherapy compared to the baseline but significantly decreased after 15 minutes (p = 0.01). RR and SA score significantly increased after suctioning (p = 0.014) but reduced after 15 minutes (p = physiotherapy (p = physiotherapy may help facilitate the overall well-being of a fragile preterm neonate. Lung auscultation finding suggests that after suctioning, there was a significant reduction in crepitation (p = 0.0000) but significant increase in crepitation after 15 minutes (p = physiotherapy. Chest physiotherapy is safe in preterm neonates. Suctioning causes significant cardio-respiratory parameter changes, but within normal physiological range. Thus, chest physiotherapy should be performed with continuous monitoring only when indicated and not as a routine procedure. More research is needed

  10. Numerical simulation of installation of skirt foundations

    Energy Technology Data Exchange (ETDEWEB)

    Vangelsten, Bjoern Vidar

    1997-12-31

    Skirt foundation has been increasingly used for permanent offshore oil installations and anchors for drilling ships. Suction is commonly used in skirt foundation installing. If a large amount of suction is applied, the soil around the foundation may fail and the foundation become useless. This thesis studies failure due to high seepage gradients, aiming to provide a basis for reducing the risk of such failures. Skirt penetration model testing has shown that to solve the problem one must understand what is going on at the skirt tip during suction installation. A numerical model based on micro mechanics was developed as continuum hypothesis was seen to be unsuitable to describe the processes in the critical phases of the failure. The numerical model combines two-dimensional elliptical particles with the finite difference method for flow to model water flow in a granular material. The key idea is to formulate the permeability as a function of the porosity of the grain assembly and so obtain an interaction between the finite difference method on flow and the particle movement. A computer program, DYNELL, was developed and used to simulate: (1) weight penetration of a skirt wall, (2) combined suction and weight penetration of a skirt wall, and (3) critical gradient tests around a skirt wall to study failure mechanisms. The model calculations agree well with laboratory experiments. 16 refs., 124 figs., 21 tabs.

  11. Broadband electromagnetic analysis of compacted kaolin

    International Nuclear Information System (INIS)

    Bore, Thierry; Scheuermann, Alexander; Wagner, Norman; Cai, Caifang

    2017-01-01

    The mechanical compaction of soil influences not only the mechanical strength and compressibility but also the hydraulic behavior in terms of hydraulic conductivity and soil suction. At the same time, electric and dielectric parameters are increasingly used to characterize soil and to relate them with mechanic and hydraulic parameters. In the presented study electromagnetic soil properties and suction were measured under defined conditions of standardized compaction tests. The impact of external mechanical stress conditions of nearly pure kaolinite was analyzed on soil suction and broadband electromagnetic soil properties. An experimental procedure was developed and validated to simultaneously determine mechanical, hydraulic and broadband (1 MHz–3 GHz) electromagnetic properties of the porous material. The frequency dependent electromagnetic properties were modeled with a classical mixture equation (advanced Lichtenecker and Rother model, ALRM) and a hydraulic-mechanical-electromagnetic coupling approach was introduced considering water saturation, soil structure (bulk density, porosity), soil suction (pore size distribution, water sorption) as well as electrical conductivity of the aqueous pore solution. Moreover, the relaxation behavior was analyzed with a generalized fractional relaxation model concerning a high-frequency water process and two interface processes extended with an apparent direct current conductivity contribution. The different modeling approaches provide a satisfactory agreement with experimental data for the real part. These results show the potential of broadband electromagnetic approaches for quantitative estimation of the hydraulic state of the soil during densification. (paper)

  12. Repair of an inguinoscrotal hernia in a patient with Becker muscular dystrophy.

    Science.gov (United States)

    Tatulli, F; Caraglia, A; Delcuratolo, A; Cassano, S; Chetta, G S

    2017-01-01

    Inguinal hernia repairs are routinely performed as outpatient procedures in most patients, whereas a few require admission due to clinical or social peculiarities. Muscular dystrophies are inherited disorders characterized by progressive muscle wasting and weakness. In case of surgery there is no definite recommendation for either general or regional anesthesia. This contribution regards a 48 y. o. male patient diagnosed with Becker Muscular Dystrophy by muscle biopsy 10 years earlier. He had a left-sided sizable inguinoscrotal hernia with repeat episodes of incarceration. An elective mesh repair with suction drainage was accomplished under selective spinal anesthesia. The post-operative course was uneventful. A few inguinal hernia repairs require admission due to peculiarities such as extensive scrotal hernias requiring suction drainage. Muscular dystrophies are inherited disorders with no cure and no two dystrophy patients are exactly alike, therefore the health issues will be different for each individual. In case of surgery there is no definite recommendation for either general or regional anesthesia. This contribution regards the successful elective mesh repair with suction drainage of a large left-sided inguino-scrotal hernia in a 48 y. o. male patient affected by Becker muscular dystrophy by selective spinal anesthesia obtained by 10 milligrams of hyperbaric bupivacaine. Effective mesh repair with suction drainage of large inguinal hernias under spinal anesthesia can be achieved in patients affected by muscular dystrophy.

  13. Airfoil for a gas turbine engine

    Science.gov (United States)

    Liang, George [Palm City, FL

    2011-05-24

    An airfoil is provided for a turbine of a gas turbine engine. The airfoil comprises: an outer structure comprising a first wall including a leading edge, a trailing edge, a pressure side, and a suction side; an inner structure comprising a second wall spaced from the first wall and at least one intermediate wall; and structure extending between the first and second walls so as to define first and second gaps between the first and second walls. The second wall and the at least one intermediate wall define at least one pressure side supply cavity and at least one suction side supply cavity. The second wall may include at least one first opening near the leading edge of the first wall. The first opening may extend from the at least one pressure side supply cavity to the first gap. The second wall may further comprise at least one second opening near the trailing edge of the outer structure. The second opening may extend from the at least one suction side supply cavity to the second gap. The first wall may comprise at least one first exit opening extending from the first gap through the pressure side of the first wall and at least one second exit opening extending from the second gap through the suction side of the second wall.

  14. Appraisal of Meconium at Delivery

    Science.gov (United States)

    Paes, Bosco A.; Thompson, Penelope

    1992-01-01

    A critical appraisal of the scientific literature on managing mesconium in labor identified 15 studies which were used to evaluate intervention strategies. Only four were randomized trials: two on the use of amnioinfusion in labor, one on the technique of bulb versus DeLee catheter suction of the newborn, and one on the need for endotracheal intubation and suction in meconium-stained neonates. Current practice is dictated by the most favorable tradeoff between benefit and risk because of limited scientific evidence. PMID:21221284

  15. Soil desiccation cracks as a suction–contraction process

    KAUST Repository

    Cordero, J. A.; Useche, G.; Prat, P. C.; Ledesma, A.; Santamarina, Carlos

    2017-01-01

    Recent macro- and particle-scale advances in unsaturated soil behaviour have led to an enhanced understanding of the effects of moisture changes on soil response. This research examines desiccation cracks as a suction–contraction-coupled process using sand–clay mixtures. Suction–moisture measurements highlight the role of fines on suction potential even at low fines content; on the other hand, oedometer tests exhibit a marked transition from sand-controlled to clay-controlled compressibility. Time-lapse photography of desiccation tests in flat trays show the onset of crack initiation and the subsequent evolution in horizontal strains; concurrent gravimetric water content measurements relate crack nucleation to suction at air entry. Suction and compressibility increase with the soil-specific surface and have a compounded effect on desiccation-driven lateral contraction. Both layer thickness and its lateral extent affect the development of desiccation cracks. The recently proposed revised soil classification system properly anticipates the transitions in compressibility and capillary phenomena observed in this study (between 15 and 35% fines content).

  16. The interventional treatment of acute renal infarction:clinical experience in six cases

    International Nuclear Information System (INIS)

    Wang Kai; Jiang Guomin; Zhao Jinwei; Li Shaoqin; Tian Feng; Huang Wenhua; Zhang Xianshun; Liu Yizhi

    2010-01-01

    Objective: To discuss the clinical characteristics of acute renal infarction and to evaluate the endovascular interventional therapy in treating acute renal infarction. Methods: Since 2006, six patients with acute renal infarction were encountered in our hospital. Renal arterial suction and thrombolytic therapy were immediately carried out as soon as the diagnosis was confirmed. The clinical data were retrospectively analyzed. Results: Based on clinical manifestations, enhanced CT scan and angiography, the diagnosis of acute renal infarction was definitely confirmed in all 6 patients. After renal arterial suction and thrombolytic therapy the clinical symptoms were markedly relieved and the blood flow in infracted area completely or partially returned to normal. Conclusion: The clinical presentation of acute renal infarction is not characteristic. For the diagnosis of acute renal infarction contrast-enhanced CT scanning and renal angiography are the exams of first choice. Renal artery suction and thrombolytic therapy is a safe and effective treatment for acute renal infarction. (authors)

  17. Phylogeny of diving beetles reveals a coevolutionary arms race between the sexes.

    Directory of Open Access Journals (Sweden)

    Johannes Bergsten

    Full Text Available BACKGROUND: Darwin illustrated his sexual selection theory with male and female morphology of diving beetles, but maintained a cooperative view of their interaction. Present theory suggests that instead sexual conflict should be a widespread evolutionary force driving both intersexual coevolutionary arms races and speciation. METHODOLOGY/PRINCIPAL FINDINGS: We combined Bayesian phylogenetics, complete taxon sampling and a multi-gene approach to test the arms race scenario on a robust diving beetle phylogeny. As predicted, suction cups in males and modified dorsal surfaces in females showed a pronounced coevolutionary pattern. The female dorsal modifications impair the attachment ability of male suction cups, but each antagonistic novelty in females corresponds to counter-differentiation of suction cups in males. CONCLUSIONS: A recently diverged sibling species pair in Japan is possibly one consequence of this arms race and we suggest that future studies on hypoxia might reveal the key to the extraordinary selection for female counter-adaptations in diving beetles.

  18. Soil desiccation cracks as a suction–contraction process

    KAUST Repository

    Cordero, J. A.

    2017-10-05

    Recent macro- and particle-scale advances in unsaturated soil behaviour have led to an enhanced understanding of the effects of moisture changes on soil response. This research examines desiccation cracks as a suction–contraction-coupled process using sand–clay mixtures. Suction–moisture measurements highlight the role of fines on suction potential even at low fines content; on the other hand, oedometer tests exhibit a marked transition from sand-controlled to clay-controlled compressibility. Time-lapse photography of desiccation tests in flat trays show the onset of crack initiation and the subsequent evolution in horizontal strains; concurrent gravimetric water content measurements relate crack nucleation to suction at air entry. Suction and compressibility increase with the soil-specific surface and have a compounded effect on desiccation-driven lateral contraction. Both layer thickness and its lateral extent affect the development of desiccation cracks. The recently proposed revised soil classification system properly anticipates the transitions in compressibility and capillary phenomena observed in this study (between 15 and 35% fines content).

  19. Safe and efficient operation of multistage cold compressor systems

    International Nuclear Information System (INIS)

    Kauschke, M.; Haberstroh, C.; Quack, H.

    1996-01-01

    Large refrigeration rates in the temperature range of super fluid helium can only be obtained with the help of centrifugal cold compressors. For the large 2 K systems, four compression stages are necessary to reach atmospheric pressure. Centrifugal cold compressors are quite sensitive to mass flow and suction temperature variations; but these have to be expected in a real system. The first step in the systems design is to find safe and efficient quasi-stationary modes of operation. The system which is being proposed for the TESLA refrigerators relies on two features. The first is to allow the room temperature screw compressor, downstream of the cold compressors to work occasionally with a subatmospheric suction pressure. The second is to stabilize the suction temperature of the third stage of compression at about 10 K. With these features it is possible, that in all modes of operation all four compressor stages operate exactly at their design point

  20. Turbine airfoil with controlled area cooling arrangement

    Science.gov (United States)

    Liang, George

    2010-04-27

    A gas turbine airfoil (10) includes a serpentine cooling path (32) with a plurality of channels (34,42,44) fluidly interconnected by a plurality of turns (38,40) for cooling the airfoil wall material. A splitter component (50) is positioned within at least one of the channels to bifurcate the channel into a pressure-side channel (46) passing in between the outer wall (28) and the inner wall (30) of the pressure side (24) and a suction-side channel (48) passing in between the outer wall (28) and the inner wall (30) of the suction side (26) longitudinally downstream of an intermediate height (52). The cross-sectional area of the pressure-side channel (46) and suction-side channel (48) are thereby controlled in spite of an increasing cross-sectional area of the airfoil along its longitudinal length, ensuring a sufficiently high mach number to provide a desired degree of cooling throughout the entire length of the airfoil.

  1. Avaliação de tanques de escorva utilizados em substituição à válvula-de-pé em instalações de bombeamento Evaluation of priming tanks using them instead of foot valve in pumping installations

    Directory of Open Access Journals (Sweden)

    Marcos O. Betini

    2008-09-01

    Full Text Available A maioria das instalações de abastecimento de água utiliza bombas hidráulicas do tipo turbobombas, requerendo que o interior de sua carcaça e da tubulação de sucção esteja preenchido com água (escorvados para que a sucção da água possa ser efetivada. O escorvamento das bombas pode ser efetuado instalando-as abaixo do reservatório de captação (bomba afogada. Quando a bomba está acima do reservatório e o escorvamento é manual, é necessário usar válvulas-de-pé, que são suscetíveis ao mau funcionamento, limitando a confiabilidade do sistema, principalmente em caso de automação. Como alternativa à válvula-de-pé, neste trabalho, foram estudados dois tanques escorva, testados no Laboratório de Hidráulica e Irrigação da FCAV/UNESP - Jaboticabal, avaliando-se situações de altura manométrica de sucção de bomba centrífuga e relações entre volume útil do tanque e volume do tubo de sucção, tendo-se concluído: a o volume do tanque de escorva é função do volume do tubo de sucção da instalação de bombeamento e da altura manométrica de sucção; b o volume do tanque de escorva pode ser calculado seguindo-se a Lei de Boyle, com percentagem de acréscimo que, neste estudo, foi de 10% para um modelo de tanque e de 30% para o segundo modelo.The majority of water supply installations use hydraulic pump-turbines, requiring their inner casing and suction pipe be water filled (primed, to allow water suction. Pumps priming can be carried out installing them under the suction reservoir (drowned pump. When pump is above the reservoir and priming is manual, it will be necessary using foot valves, which are subjected to bad working, with a reduction of system reliability, mainly with automation. In this work, as an alternative to foot valves, two priming tanks were inquired, tested in the FCAV/UNESP-Jaboticabal, Brazil, Laboratory of Hydraulics and Irrigation, with the evaluation of suction head situations of centrifugal

  2. Determination of Volumetric Losses in Hydrodynamic Pump Using Numerical Modelling

    Directory of Open Access Journals (Sweden)

    Lukáš ZAVADIL

    2012-06-01

    Full Text Available This paper deals with the numerical modelling of the flow in the single-stage centrifugal pump. The main objective is to determine leakage losses through annular seals at the suction side of the pump. Leakage through a shaft seal is not included in the simulation. The amount of liquid that circulates from the impeller discharge back to suction of the pump is determined in dependence on the flow rate. Losses in the pump are further discussed as well as the possibility of their prediction.

  3. The flow of a non-Newtonian fluid induced due to the oscillations of a porous plate

    Directory of Open Access Journals (Sweden)

    S. Asghar

    2004-01-01

    Full Text Available An analytic solution of the flow of a third-grade fluid on a porous plate is constructed. The porous plate is executing oscillations in its own plane with superimposed injection or suction. An increasing or decreasing velocity amplitude of the oscillating porous plate is also examined. It is also shown that in case of third-grade fluid, a combination of suction/injection and decreasing/increasing velocity amplitude is possible as well. Several limiting situations with their implications are given and discussed.

  4. A Simple, Safe Technique for Thorough Seroma Evacuation in the Outpatient Setting

    Directory of Open Access Journals (Sweden)

    Julie E. Park, MD, FACS

    2014-09-01

    Full Text Available Summary: Seroma formation, a common postoperative complication in reconstructive cases, can lead to capsular contracture and increased office visits and expenses. The authors present a safe, novel technique for ensuring the thorough removal of serous fluid in the outpatient setting. By relying on access with an angiocatheter, potential injury to permanent implants is minimized. The use of low continuous wall suction obviates the need of manual suction via multiple syringes and offers a rapid and thorough evacuation of all types of seromas.

  5. Early medical abortion with methotrexate and misoprostol.

    Science.gov (United States)

    Borgatta, L; Burnhill, M S; Tyson, J; Leonhardt, K K; Hausknecht, R U; Haskell, S

    2001-01-01

    To evaluate the introduction of an early medical abortion program with methotrexate and misoprostol, using a standardized protocol. A total of 1973 women at 34 Planned Parenthood sites participated in a case series of early medical abortion. Ultrasound was used to confirm gestational age of less than 49 days from the first day of the last menstrual period. Women were given intramuscular methotrexate 50 mg/m(2) of body surface area on day 1, and then they inserted misoprostol 800 microg vaginally at home on day 5, 6, or 7. Women were advised to have a suction curettage if the pregnancy appeared viable 2 weeks after methotrexate or if any gestational sac persisted 4 weeks after methotrexate. Outcomes were complete medical abortion and suction curettage. Sixteen hundred fifty-nine women (84.1%) had a complete medical abortion, and 257 (13.0%) had suction curettage. The most common reason for curettage was patient option (8.9%). At 2 weeks after methotrexate use, 1.4% of women had curettage because of a viable pregnancy; at 4 weeks, 1.6% of women had curettage because of a persistent but nonviable pregnancy. One percent of women had curettage because of physician recommendation, most commonly for bleeding. Suction curettage rates decreased with site experience (P <.006) and were lower at early gestational ages (P <.004) and in nulliparous women (P <.004). Medical abortion with methotrexate and misoprostol is safe and effective and can be offered in a community setting.

  6. Current practice in airway management: A descriptive evaluation.

    Science.gov (United States)

    Kjonegaard, Rebecca; Fields, Willa; King, Major L

    2010-03-01

    Ventilator-associated pneumonia, a common complication of mechanical ventilation, could be reduced if health care workers implemented evidence-based practices that decrease the risk for this complication. To determine current practice and differences in practices between registered nurses and respiratory therapists in managing patients receiving mechanical ventilation. A descriptive comparative design was used. A convenience sample of 41 registered nurses and 25 respiratory therapists who manage critical care patients treated with mechanical ventilation at Sharp Grossmont Hospital, La Mesa, California, completed a survey on suctioning techniques and airway management practices. Descriptive and inferential statistics were used to analyze the data. Significant differences existed between nurses and respiratory therapists for hyperoxygenation before suctioning (P =.03). In the 2 groups, nurses used the ventilator for hyper-oxygenation more often, and respiratory therapists used a bag-valve device more often (P =.03). Respiratory therapists instilled saline (P <.001) and rinsed the closed system with saline after suctioning (P =.003) more often than nurses did. Nurses suctioned oral secretions (P <.001) and the nose of orally intubated patients (P =.01), brushed patients' teeth with a toothbrush (P<.001), and used oral swabs to clean the mouth (P <.001) more frequently than respiratory therapists did. Nurses and respiratory therapists differed significantly in the management of patients receiving mechanical ventilation. To reduce the risk of ventilator-associated pneumonia, both nurses and respiratory therapists must be consistent in using best practices when managing patients treated with mechanical ventilation.

  7. Compressor Calorimeter Test of R-404A Alternatives ARM-31a, D2Y-65, L-40, and R32 + R-134a Mixture using a Scroll Compressor

    Energy Technology Data Exchange (ETDEWEB)

    Shrestha, Som S [ORNL; Sharma, Vishaldeep [ORNL; Abdelaziz, Omar [ORNL

    2013-08-01

    As a contribution to the AHRI Low-GWP Alternative Refrigerants Evaluation Program (AREP), this study compares the performance of four lower-GWP alternative refrigerants, ARM-31a, D2Y-65, L-40, and R-32 + R-134a mixture, to that of refrigerant R-404A (baseline) in a scroll compressor designed for medium temperature refrigeration applications. These comparisons were carried out via compressor calorimeter tests performed on a compressor designed for refrigerant R-404A and having a nominal rated capacity of 23,500 Btu/hr. Tests were conducted over a suction dew point temperature range of -10 F to 35 F in 5 F increments and a discharge dew point temperature range of 70 F to 140 F in 10 F increments. All the tests were performed with 20 F superheat, 40 F superheat, and 65 F suction temperature. A liquid subcooling level of 10 F to 15 F was maintained for all the test conditions. However, the cooling capacities reported in this study are normalized for 0 F subcooling. The tests showed that the compressor energy efficiency ratio (EER) and cooling capacity with all four alternative refrigerants tested are higher at higher saturation suction and saturation discharge temperature and lower at lower saturation suction and saturation discharge temperature, compared to that of R-404A. Discharge temperatures of all the alternative refrigerants were higher than that of R-404A at all test conditions.

  8. Thermo-mechanical constitutive modeling of unsaturated clays based on the critical state concepts

    Directory of Open Access Journals (Sweden)

    Saeed Tourchi

    2015-04-01

    Full Text Available A thermo-mechanical constitutive model for unsaturated clays is constructed based on the existing model for saturated clays originally proposed by the authors. The saturated clays model was formulated in the framework of critical state soil mechanics and modified Cam-clay model. The existing model has been generalized to simulate the experimentally observed behavior of unsaturated clays by introducing Bishop's stress and suction as independent stress parameters and modifying the hardening rule and yield criterion to take into account the role of suction. Also, according to previous studies, an increase in temperature causes a reduction in specific volume. A reduction in suction (wetting for a given confining stress may induce an irreversible volumetric compression (collapse. Thus an increase in suction (drying raises a specific volume i.e. the movement of normal consolidation line (NCL to higher values of void ratio. However, some experimental data confirm the assumption that this reduction is dependent on the stress level of soil element. A generalized approach considering the effect of stress level on the magnitude of clays thermal dependency in compression plane is proposed in this study. The number of modeling parameters is kept to a minimum, and they all have clear physical interpretations, to facilitate the usefulness of model for practical applications. A step-by-step procedure used for parameter calibration is also described. The model is finally evaluated using a comprehensive set of experimental data for the thermo-mechanical behavior of unsaturated soils.

  9. Beat-by-beat analysis of cardiac output and blood pressure responses to short-term barostimulation in different body positions

    Science.gov (United States)

    Hildebrandt, Wulf; Schütze, Harald; Stegemann, J.

    Rapid quantification of the human baro-reflex control of heart rate has been achieved on a beat-by-beat basis using a neck-chamber with quick ECG-triggered pressure changes. Referring to recent findings on heart rate and stroke volume, the present study uses this technique to compare cardiac output as well as blood pressure changes in supine and upright position to investigate feedback effects and to confirm postural reflex modifications not revealed by RR-interval changes. A suction profile starting at +40 mmHg and running 7 steps of pressure decrease down to -65 mmHg was examined in 0° and 90° tilting position while beat-by-beat recordings were done of heart rate, stroke volume (impedance-cardiography) and blood pressure (Finapres tm) (n=16). The percentual heart rate decrease failed to be significantly different between positions. A suction-induced stroke volume increase led to a cardiac output almost maintained when supine and significantly increased when upright. A decrease in all blood pressure values was found during suction, except for systolic values in upright position which increased. Conclusively, (a) it is confirmed that different inotropy accounts for the seen gravitational effect on the cardiac output not represented by heart rate; (b) identical suction levels in different positions lead to different stimuli at the carotid receptor. This interference has to be considered in microgravity studies by beat-by-beat measurement of cardiac output and blood pressure.

  10. Characterisation of textile shape and position upstream of a wastewater pump under different part load conditions

    DEFF Research Database (Denmark)

    Jensen, Anna Lyhne; Sørensen, Henrik; Rosendahl, Lasse Aistrup

    2018-01-01

    Accumulations of sanitary textile materials often lead to clogging of pumps in the wastewater system. Simulation of clogging phenomena may help to identify means of reducing the risk of clogging. In order to provide realistic initial conditions for clogging simulations, this study characterises...... textiles in artificial wastewater in the suction pipe to a dry-installed pump at nine different operating points. The textiles are recorded approximately 3.5 pipe diameters from the pump inlet and approximately three pipe diameters from the suction pipe bend at pipe Reynolds numbers in the range 300...

  11. Magnetohydrodynamic flow of a rarefied gas near an accelerated porous plate

    International Nuclear Information System (INIS)

    Kant, R.

    1978-01-01

    An investigation is made of the flow of an electrically conducting rarefied gas due to the time-varying motion of an infinite porous plate, the gas being permeated by a transverse magnetic field. The suction is taken to be a constant and the magnetic lines of force are taken to be fixed relative to the fluid. The effects of magnetic field, rarefaction parameter, suction parameter are shown by means of some tables. The expressions of the skin friction for the two particular cases have also been obtained. (author)

  12. Inverse analyses of effective diffusion parameters relevant for a two-phase moisture model of cementitious materials

    DEFF Research Database (Denmark)

    Addassi, Mouadh; Johannesson, Björn; Wadsö, Lars

    2018-01-01

    Here we present an inverse analyses approach to determining the two-phase moisture transport properties relevant to concrete durability modeling. The purposed moisture transport model was based on a continuum approach with two truly separate equations for the liquid and gas phase being connected...... test, and, (iv) capillary suction test. Mass change over time, as obtained from the drying test, the two different cup test intervals and the capillary suction test, was used to obtain the effective diffusion parameters using the proposed inverse analyses approach. The moisture properties obtained...

  13. Computational analysis of locally forced flow over a wall-mounted hump at high-Re number

    International Nuclear Information System (INIS)

    Saric, S.; Jakirlic, S.; Djugum, A.; Tropea, C.

    2006-01-01

    An incompressible, high-Reynolds number flow (slightly less then 1 Mio. per chord) over a smoothly contoured, asymmetric, wall-mounted hump was computationally studied using the LES (large eddy simulation) and DES (detached eddy simulation) methods. In addition, several second-moment and eddy-viscosity closures within the RANS (Reynolds-averaged Navier-Stokes) framework were tested. The focus of the investigation was on the effects of local perturbation of the hump boundary layer introduced by spatially uniform (in the spanwise direction) steady suction and oscillatory suction/blowing through a narrow opening (1.7 mm) situated at the hump crest immediately upstream of the natural separation point. Reference experiments have shown that both flow control mechanisms cause a shortening of the recirculation bubble relative to the baseline configuration with no flow control. All statistical turbulence models used in the RANS framework resulted in a substantially larger recirculation zone independent of the modelling level, being a consequence of a too low turbulence level in the separated shear layer. Accordingly, the effect of the steady suction, namely the reduction of the reattachment length, was underpredicted. The LES method, despite a relatively coarse mesh (with a total of 4 Mio. cells) for such a high-Reynolds number, wall-bounded flow, was capable of capturing important effects of the flow control qualitatively and quantitatively. DES failed to do so in the suction case, despite good results in the baseline and oscillatory blowing/suction cases, indicating that a shallow separation from curved surfaces poses a challenge to this hybrid RANS/LES strategy. A sensitivity study of the RANS/LES interface position within the DES approach shows that a RANS region chosen too thin (with the interface situated at the very beginning of the logarithmic layer) can lead to a strong reduction of the turbulent viscosity causing a low turbulence level within the shear layer

  14. Scale effect on the water retention curve of a volcanic ash

    Science.gov (United States)

    Damiano, Emilia; Comegna, Luca; Greco, Roberto; Guida, Andrea; Olivares, Lucio; Picarelli, Luciano

    2015-04-01

    During the last decades, a number of flowslides and debris flows triggered by intense rainfall affected a wide mountainous area surrounding the "Campania Plain" (southern Italy). The involved slopes are constituted by shallow unsaturated air-fall deposits of pyroclastic nature, which stability is guaranteed by the contribution of suction on shear strength. To reliably predict the onset of slope failure triggered by critical precipitations, is essential to understand the infiltration process and the soil suction distribution in such granular deposits. The paper presents the results of a series of investigation performed at different scales to determine the soil water retention curve (SWRC) of a volcanic ash which is an es-sential element in the analysis of the infiltration processes. The soil, a silty sand, was taken at Cervinara hillslope, 30 km East of Naples, just aside an area which had been subjected to a catastrophic flowslide. The SWRC was obtained through: - standard tests in a suction-controlled triaxial apparatus (SCTX), in a pressure plate and by the Wind technique (1968) on small natural and reconstituted soil samples (sample dimensions in the order of the 1•10-6m3) ; - infiltration tests on small-scale model slopes reconstituted in an instrumented flume (sample dimensions in the order of 5•10-3m3); - suction and water content monitoring at the automatic station installed along the Cervinara hillslope. The experimental points generally were defined by coupling suction measurements through jet-fill tensiometers and water content through TDR probes installed close each others. The obtained data sets individuate three different curves characterized by different shapes in the transition zone: at larger volume element dimensions correspond curves which exhibit steeper slopes and lower values of the water content in the transition zone. This result confirms the great role of the volume element dimensions in the de-termination of hydraulic characteristics

  15. Routine versus Selective Postoperative Nasogastric Suction In ...

    African Journals Online (AJOL)

    user

    2005-12-02

    Dec 2, 2005 ... Mobilization of the patient in the postoperative period is dependent on the presence of a NGT. The longer it is kept in place the longer will be the duration of patients' restriction in bed. Prolonged immobilization after surgery infact enhances the risk of postoperative complication like DVT and delays recovery ...

  16. Effectiveness of evacuating combustible gases by two parallel expellers closely coupled at one end of a gas pipeline

    International Nuclear Information System (INIS)

    Hawryluk, A.; Botros, K.K.

    2008-01-01

    Expeller performance has been formulated in terms of its capability to create suction pressure at the throat. This formulation has been used to assess the effectiveness of evacuating combustible gases from a pipeline section from one end using dual expellers mounted in parallel on two adjacent blow-down stacks. A general formulation was derived to address any situation of asymmetry in the stack resistance, asymmetry in the expellers' power as well overall pipeline resistance to suction flow. Solutions of the closed-form equations were obtained and presented on performance graphs showing the ratio of the suction flow using dual expellers to that using either one in a single mode. It was found that there are conditions at which expelling with dual expellers exceed that of either expeller operating alone. It was also shown that when asymmetric expellers are used, where one expeller is more powerful than the other, the benefits of using two expellers is realized up to a limiting degree of asymmetry, beyond which the weaker expeller could be stalled and then reverse flow

  17. Liposuction devices: technology update.

    Science.gov (United States)

    Shridharani, Sachin M; Broyles, Justin M; Matarasso, Alan

    2014-01-01

    Since its introduction by Illouz and others over 30 years ago, suction-assisted lipectomy/liposuction/lipoplasty has evolved tremendously and has developed into one of the most popular procedures in aesthetic plastic surgery. Liposuction is an effective procedure employed to treat localized adipose deposits in patients not suffering from generalized obesity. These accumulations of subcutaneous fat often occur in predictable distributions in both men and women. A cannula connected to a suction-generating source allows for small incisions to be strategically placed and large volumes of fat to be removed. This fat removal leads to improved harmonious balance of a patient's physique and improved body contour. Various surgical techniques are available and have evolved as technology has improved. Current technology for liposuction includes suction-assisted lipectomy, ultrasound-assisted, power-assisted, laser-assisted, and radiofrequency-assisted. The choice of technology and technique often depends on patient characteristics and surgeon preference. The objective of this review is to provide a thorough assessment of current technologies available to plastic surgeons performing liposuction.

  18. Heated air humidification versus cold air nebulization in newly tracheostomized patients.

    Science.gov (United States)

    Birk, Richard; Händel, Alexander; Wenzel, Angela; Kramer, Benedikt; Aderhold, Christoph; Hörmann, Karl; Stuck, Boris A; Sommer, J Ulrich

    2017-12-01

    After tracheostomy, the airway lacks an essential mechanism for warming and humidifying the inspired air with the consequent functional impairment and discomfort. The purpose of this study was to compare airway hydration with cold-air nebulization versus heated high-flow humidification on medical interventions and tracheal ciliary beat frequency (CBF). Newly tracheostomized patients (n = 20) were treated either with cold-air nebulization or heated humidification. The number of required tracheal suctioning procedures to clean the trachea and tracheal CBF were assessed. The number of required suctions per day was significantly lower in the heated humidification group with medians 3 versus 5 times per day. Mean CBF was significantly higher in the heated humidification group (6.36 ± 1.49 Hz) compared to the cold-air nebulization group (3.99 ± 1.39 Hz). The data suggest that heated humidification enhanced mucociliary transport leading to a reduced number of required suctioning procedures in the trachea, which may improve postoperative patient care. © 2017 The Authors Head & Neck Published by Wiley Periodicals, Inc.

  19. Design and preliminary test results at Mach 5 of an axisymmetric slotted sound shield. [for supersonic wind tunnels (noise reduction in wind tunnel nozzles)

    Science.gov (United States)

    Beckwith, I. E.; Spokowski, A. J.; Harvey, W. D.; Stainback, P. C.

    1975-01-01

    The basic theory and sound attenuation mechanisms, the design procedures, and preliminary experimental results are presented for a small axisymmetric sound shield for supersonic wind tunnels. The shield consists of an array of small diameter rods aligned nearly parallel to the entrance flow with small gaps between the rods for boundary layer suction. Results show that at the lowest test Reynolds number (based on rod diameter) of 52,000 the noise shield reduced the test section noise by about 60 percent ( or 8 db attenuation) but no attenuation was measured for the higher range of test reynolds numbers from 73,000 to 190,000. These results are below expectations based on data reported elsewhere on a flat sound shield model. The smaller attenuation from the present tests is attributed to insufficient suction at the gaps to prevent feedback of vacuum manifold noise into the shielded test flow and to insufficient suction to prevent transition of the rod boundary layers to turbulent flow at the higher Reynolds numbers. Schlieren photographs of the flow are shown.

  20. Numerical simulation of the flow through a compressor-valve model using an immersed-boundary method

    Directory of Open Access Journals (Sweden)

    Franco Barbi

    2016-01-01

    Full Text Available Hermetic reciprocating compressors are widely used in small- and medium-size refrigeration systems based on the vapor-compression cycle. One of the main parts of this type of compressor is the automatic valve system used to control the suction and discharge processes. As the suction and discharge losses represent a large amount of the total thermodynamic losses (47%, a small improvement in the suction and discharge processes can produce expressive increases in the thermodynamic efficiency of the compressor. In this work, a new numerical methodology is applied to solve the flow through reed-type valves. The numerical results were experimentally validated through the pressure distribution acting on the frontal disk of a radial diffuser, which is a geometry usually used to model this type of valve. The numerical results for the velocity and pressure fields were comprehensively explored during the opening and closing movement imposed to the reed. The good quality of these results show that the numerical methodology is very promising in terms of solving the flow in the actual dynamics of reed-type valves.

  1. BLOCKAGE 2.5 reference manual

    International Nuclear Information System (INIS)

    Shaffer, C.J.; Brideau, J.; Rao, D.V.; Bernahl, W.

    1996-12-01

    The BLOCKAGE 2.5 code was developed by the US Nuclear Regulatory Commission (NRC) as a tool to evaluate license compliance regarding the design of suction strainers for emergency core cooling system (ECCS) pumps in boiling water reactors (BWR) as required by NRC Bulletin 96-03, ''Potential Plugging of Emergency Core Cooling Suction Strainers by Debris in Boiling Water Reactors''. Science and Engineering Associates, Inc. (SEA) and Software Edge, Inc. (SE) developed this PC-based code. The instructions to effectively use this code to evaluate the potential of debris to sufficiently block a pump suction strainer such that a pump could lose NPSH margin was documented in a User's Manual (NRC, NUREG/CR-6370). The Reference Manual contains additional information that supports the use of BLOCKAGE 2.5. It contains descriptions of the analytical models contained in the code, programmer guides illustrating the structure of the code, and summaries of coding verification and model validation exercises that were performed to ensure that the analytical models were correctly coded and applicable to the evaluation of BWR pump suction strainers. The BLOCKAGE code was developed by SEA and programmed in FORTRAN as a code that can be executed from the DOS level on a PC. A graphical users interface (GUI) was then developed by SEA to make BLOCKAGE easier to use and to provide graphical output capability. The GUI was programmed in the C language. The user has the option of executing BLOCKAGE 2.5 with the GUI or from the DOS level and the Users Manual provides instruction for both methods of execution

  2. Study of the variation of B with Sr

    Directory of Open Access Journals (Sweden)

    Morvan Mathilde

    2016-01-01

    Full Text Available Skempton coefficient B is commonly used to verify the saturation of a sample before triaxial testing. This coefficient is obtained during undrained isotropic consolidation and is defined as the ratio between the increment of pore pressure u measured and the imposed increment of isotropic stress. This coefficient varies between 0 for dry soils and 1 for saturated soils. Many studies on liquefaction of unsaturated soils were published using Skempton coefficient B to represent saturation degree Sr of soil. On the first hand, this variation of B coefficient with saturation degree is mostly due to the compressibility of air in the pores. On the second hand, we also know that the presence of air as a fluid phase gives birth to suction after equilibrium is reached inside the sample. The higher the suction, the stiffer the soil skeleton. These two phenomena are opposite. Their effects in laboratory testing depend on the experimental apparatus. For example, if we consider an unsaturated triaxial device, we will have to take suction into account. On the contrary if we plan to break the menisci just before measuring B, suction equilibration will not occur. Experimental tests were performed to show the difference between these two cases and to study the equilibrium phase. Based on these observations, this article presents new relationships that permit to calculate saturation degree with a given Skempton coefficient with different hypotheses and with different experimental devices. These results are confronted to the commonly used relation given by Lade and the difference between all these calculations is studied.

  3. In vitro catheter and sorbent-based method for clearance of radiocontrast material during cerebral interventions

    International Nuclear Information System (INIS)

    Angheloiu, George O.; Hänscheid, Heribert; Reiners, Christoph; Anderson, William D.; Kellum, John A.

    2013-01-01

    Background: Contrast-induced acute kidney injury is a severe condition resulting from the use of radiology contrast in patients with predisposing factors. Hypothesis: We hypothesized that a novel system including a device containing polymer resin sorbent beads and a custom-made suctioning catheter could efficiently remove contrast from an in vitro novel model of circulatory system (MOCS) mimicking the cerebral circulation. Methods: A custom-made catheter was built and optimized for cerebral venous approach. The efficiency of a system made of a polymer resin sorbent beads column (CST 401, Cytosorbents) and this particular catheter was tested in the MOCS running a solution composed of 0.9% saline and radio-contrast. During two series of 18 cycles of first-pass experiments we assessed the catheter's suctioning efficiency and the system's ability to clear radio-contrast injected into the MOCS's cerebral arterial segment. We also assessed the functioning and reliability of the MOCS. Results: Mean suctioning efficiency of the catheter was 84% ± 24%. The polymer sorbent column contrast removal rate was initially 96% and gradually decreased with subsequent cycles in a linear fashion during an experiment lasting approximately 90 minutes. The MOCS had a reliability of 0.9946×min −1 where 1 × min −1 was the optimum value. Conclusion: A system including a polymer resin sorbent beads column and a custom-made suctioning catheter had an excellent initial efficiency in quickly removing contrast from an artificial MOCS mimicking the cerebral circulation. MOCS is an inexpensive and relatively reliable custom-made system that can be used for training or testing purposes

  4. Advances and challenges in periodic forcing of the turbulent boundary layer on a body of revolution

    Science.gov (United States)

    Kornilov, V. I.; Boiko, A. V.

    2018-04-01

    The effectiveness of local forcing by periodic blowing/suction through a thin transverse slot to alter the properties of an incompressible turbulent boundary layer is considered. In the first part of the review the effectiveness of the forcing through a single slot is discussed. Analysis of approaches for experimental modeling of the forcing, including those on flat plate, is given. Some ambiguities in simulating such flows are reviewed. The main factors affecting the structure of the forced flow are analyzed. In the second part the effectiveness of the forcing on a body of revolution by periodic blowing/suction through a series of transverse annular slots is discussed. The focus is the structure, properties, and main regularities of the forced flows in a wide range of variable conditions and basic parameters such as the Reynolds number, the dimensionless amplitude of the forced signal, and the frequency of the forced signal. The effect of the forcing on skin-friction in the turbulent boundary layer is clearly revealed. A phase synchronism of blowing/suction using an independent control of the forcing through the slots provides an additional skin friction reduction at distances up to 5-6 boundary layer displacement thicknesses upstream of an annular slot. The local skin friction reduction under the effect of periodic blowing/suction is stipulated by a dominating influence of an unsteady coherent vortex formed in the boundary layer, the vortex propagating downstream promoting a shift of low-velocity fluid further from the wall, a formation of a retarded region at the wall, and hence, a thickening of the viscous sublayer.

  5. Robot Beroda Perambat Dinding Berbasis Mikrokontroler ATmega 2560 Dilengkapi Kendali Nirkabel dan Penghindar Rintangan

    Directory of Open Access Journals (Sweden)

    Eko Didik Widianto

    2017-05-01

    Full Text Available This research developed a mobile wall climbing robot prototype using 4 DC motors as its driver and a suction tube. It can avoid obstacles. This robot uses Arduino Mega 2560 as its controller board. The robot's weight is 747 grams. The suction tube produces a suction force of 7.815N capable of holding the robot load in a stall vertical position using 12V of voltage. The robot able to crawl down and horizontal, but still can not climb vertically. The robot is able to receive a command of motion manually from a 2.4GHz wireless joystick. In automatic mode, the robot can avoid obstacles using the HC-SR04 proximity sensor. This research also shows the relationship between suction force and the given voltage of DC brushless motor and its throtle value. Penelitian ini mengembangkan sebuah purwarupa robot perambat dinding beroda dengan 4 buah motor DC sebagai penggerak dan sebuah tabung hisap serta dapat menghindari rintangan. Robot ini menggunakan Arduino Mega 2560 sebagai papan kontrolernya. Bobot robot adalah 747 gram. Gaya hisap dari tabung hisap sebesar 7,815N mampu menahan beban robot dalam posisi diam vertikal di tegangan 12V. Robot mampu merambat turun dan mendatar, namun masih tidak bisa naik vertikal. Robot mampu diberikan perintah gerak secara manual dari tombol joystick playstation nirkabel 2,4 GHz. Di mode otomatis, robot dapat bergerak menghindari rintangan menggunakan sensor jarak HC-SR04. Dalam penelitian ini ditunjukkan hubungan antara gaya hisap dengan nilai tegangan motor DC brushless dan nilai throtle-nya.

  6. Benchtop evaluation of pressure barrier insufflator and standard insufflator systems.

    Science.gov (United States)

    Nepple, Kenneth G; Kallogjeri, Dorina; Bhayani, Sam B

    2013-01-01

    Previous experimental research has reported minimal differences in pressure maintenance between different versions of standard insufflators (SI). However, a recent report identified potential clinical benefits with a valveless pressure barrier insufflator (PBI). We sought to perform a benchtop objective evaluation of SI and PBI systems. A rigid box system with continuous pressure manometry was used to evaluate a PBI (Surgiquest Airseal) and two SIs (SI1 = Stryker PneumoSure High Flow Insufflator and SI2 = Storz SCB Thermoflator). Pressure maintenance of 15 mmHg was evaluated during experimental conditions of leakage from a 5 mm port site, leakage from a 12 mm port site, and continuous suction. With leakage from the 5 mm port site, the PBI maintained pressure of >13 mmHg whereas the pressures dropped moderately with the SI1 (7-13 mmHg) and SI2 insufflators (3-7 mmHg) and did not regain goal pressure until leakage was stopped. With leakage from 12 mm port site, the PBI pressure decreased to 9-11 mmHg, whereas the SI1 and SI2 lost insufflation pressures completely. The PBI maintained pressure of >11 mmHg during continuous suction while the SI1 and SI2 lost pressure entirely, and actually showed negative pressure from air suction into the rigid box system. When evaluated statistically with the mixed model repeated measures ANOVA, the SI1 and SI2 performed similarly while the PBI maintained increased pressure. In the experimental rigid box system, the PBI more successfully maintained pressure in response to leakage and suction than SIs.

  7. Numerical analysis of hydrogen and methane propagation during testing of combustion engines

    Directory of Open Access Journals (Sweden)

    Dvořák V.

    2007-10-01

    Full Text Available The research of gas-fuelled combustion engines using hydrogen or methane require accordingly equipped test benches which take respect to the higher dangerous of self ignition accidents. This article deals with numerical calculations of flow in laboratory during simulated leakage of gas-fuel from fuel system of tested engine. The influences of local suction and influences of roof exhausters on the flow in the laboratory and on the gas propagation are discussed. Results obtained for hydrogen and for methane are compared. Conclusions for design and performance of suction devices and test benches are deduced from these results.

  8. Device on a diesel motor to supply power to emergency aggregates

    International Nuclear Information System (INIS)

    Koch, C.; Boekemeier, V.; Schilling, R.

    1977-01-01

    The invented arrangement of a diesel motor for the emergency supply of a nuclear power plant ensures that in the case of a fire in the environment of the emergency feeding building, no air with too much flue gas reaches the diesel motor via the suction pipe. The discharge pipe with a nozzle-shaped discharge opening and the suction pipe running above it pass horizontally through a wall of the building. There are vertical walls on both sides of the openings which prevent a sideways flowing of air to the exhaust gas flow in the vicinity of the building. (HGOE) [de

  9. Traumatic retropharyngeal emphysema as a cause for severe respiratory distress in a newborn

    International Nuclear Information System (INIS)

    Barlev, Dan M.; Nagourney, Beth A.; Saintonge, Ronald

    2003-01-01

    Traumatic injury to the pharynx or esophagus in a newborn from intubation or tube suctioning may have various presentations. Difficulty passing a gastric tube or feeding problems may erroneously suggest the diagnosis of esophageal atresia. Associated respiratory distress may be caused by pneumothorax or pleural effusion if the pleural space is entered. We report the case of a full-term newborn presenting with severe respiratory distress caused by a large retropharyngeal air collection resulting from hypopharyngeal perforation from prior intubation and suctioning. Chest abnormality, sufficient to account for the degree of respiratory distress, was not demonstrated. (orig.)

  10. Main boiler feed pump for fast breeder test reactor. Failure analysis and remedial measures

    International Nuclear Information System (INIS)

    Iyer, M.A.K.; Chande, S.K.; Raghuvir, A.D.; Baskar, S.; Kale, R.D.

    1994-01-01

    A small capacity ten stage 670 kw feed water pump is used for supplying feed water at a temperature of 190 deg C to a once through steam generator in the Fast Breeder Test Reactor at Kalpakkam. During preparatory heating up stage to commission the steam generator the pump suffered a severe loss of suction which resulted in failure of hydrostatic journal bearings and extensive damage to pump internals. This paper discusses the detailed mechanism of loss of suction, details of damage to the pump and various modifications carried out to prevent recurrence of the problem. (author). 4 refs., 3 figs., 2 tabs

  11. Large Eddy Simulation of the ventilated wave boundary layer

    DEFF Research Database (Denmark)

    Lohmann, Iris P.; Fredsøe, Jørgen; Sumer, B. Mutlu

    2006-01-01

    A Large Eddy Simulation (LES) of (1) a fully developed turbulent wave boundary layer and (2) case 1 subject to ventilation (i.e., suction and injection varying alternately in phase) has been performed, using the Smagorinsky subgrid-scale model to express the subgrid viscosity. The model was found...... slows down the flow in the full vertical extent of the boundary layer, destabilizes the flow and decreases the mean bed shear stress significantly; whereas suction generally speeds up the flow in the full vertical extent of the boundary layer, stabilizes the flow and increases the mean bed shear stress...

  12. Design of a new urban wind turbine airfoil using a pressure-load inverse method

    Energy Technology Data Exchange (ETDEWEB)

    Henriques, J.C.C.; Gato, L.M.C. [IDMEC, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Marques da Silva, F. [LNEC - Laboratorio Nacional de Engenharia Civil, Av. Brasil, 101, 1700-066 Lisboa (Portugal); Estanqueiro, A.I. [INETI - Instituto Nacional de Engenharia, Tecnologia e Inovacao Estrada do Paco do Lumiar, 1649-038 Lisboa (Portugal)

    2009-12-15

    This paper presents the design methodology of a new wind turbine airfoil that achieves high performance in urban environment by increasing the maximum lift. For this purpose, an inverse method was applied to obtain a new wind turbine blade section with constant pressure-load along the chord, at the design inlet angle. In comparison with conventional blade section designs, the new airfoil has increased maximum lift, reduced leading edge suction peak and controlled soft-stall behaviour, due to a reduction of the adverse pressure gradient on the suction side. Wind tunnel experimental results confirmed the computational results. (author)

  13. Glass forming ability and magnetic properties of Co{sub (40.2−x)}Fe{sub (20.1+x)}Ni{sub 6.7}B{sub 22.7}Si{sub 5.3}Nb{sub 5} (x=0–10) bulk metallic glasses produced by suction casting

    Energy Technology Data Exchange (ETDEWEB)

    Sarlar, Kagan [Physics Department, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Physics Department, Kamil Ozdag Faculty of Sciences, Karamanoglu Mehmetbey University, YunusEmre Campus, 70100 Karaman (Turkey); Kucuk, Ilker, E-mail: ikucuk@uludag.edu.tr [Physics Department, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey)

    2015-01-15

    The effect of Fe concentration on the glass forming ability (GFA) and magnetic properties in Co{sub (40.2−x)}Fe{sub (20.1+x)}Ni{sub 6.7}B{sub 22.7}Si{sub 5.3}Nb{sub 5} (x=0–10) bulk metallic glasses were investigated. By suction casting method, the bulk metallic glasses with diameters up to 2 mm were produced. We try to find out which Fe concentration makes an influence on Co based system's magnetic properties and glass forming ability. The curves of thermal analysis, obtained using differential scanning calorimetry (DSC), show that the Co{sub (40.2−x)}Fe{sub (20.1+x)}Ni{sub 6.7}B{sub 22.7}Si{sub 5.3}Nb{sub 5} (x=0–10) have a supercooled liquid region (∆T{sub x}) of about 44 K. The saturation magnetizations (J{sub s}) for as-cast BMG alloys were in the range of 0.62 T−0.81 T. - Highlights: • The effect of Fe concentration on the glass forming ability. • The substitution of an appropriate amount of Fe can enhance the GFA. • The substitution of Fe for Co also improves soft magnetic properties of the BMGs. • The high of J{sub s} 0.62−0.81 T with a low H{sub c} of 2−289 A/m of the alloys.

  14. Optimisation of irrigation regime for early potatoes, late cauliflower, early cabbage and celery

    International Nuclear Information System (INIS)

    Zavadil, J.

    2006-01-01

    The paper deals with optimisation of threshold suction pressure of soil water on light soils for early potatoes, early cabbage, late cauliflower and celery on the basis of results from small-plot field experiments with differentiated irrigation regimes. Threshold suction pressures of soil water were identical for all crops: 15 kPa in treatment I, 30 kPa in treatment II, 60 kPa in treatment III, and 120 kPa in treatment IV. Precipitation, air temperature and relative humidity, global solar radiation, wind speed and direction were measured by an automated meteorological station. Reference and actual evapotranspirations were determined for the experimental crops according to FAO Paper No. 56 and by means of a biological curve (BC) in 2003-2005. To compare these two methods of calculation of actual evapotranspiration the soil moisture balance was found out. The optimum threshold suction pressure was 30 kPa for early potatoes, late cauliflower and cabbage and 15 kPa for celery. The seasonal irrigation depths determined on the basis of soil moisture balance, in which the crop evapotranspiration (ETc) was calculated either according to FAO 56 or by the BC, were substantially different from the really achieved irrigation depths with optimal suction pressure. The really achieved values were near to the depths calculated by the BC for potatoes, while for cauliflower, cabbage and celery they were similar to the depths calculated by the FAO 56 methodology. The theoretical irrigation depths calculated by the BC method sometimes differed substantially from those based on FAO 56. These differences were maximal for cauliflower and celery and minimal for cabbage. They decreased with decreasing irrigation depths. (author)

  15. Performance study of a twin-screw expander used in a geothermal organic Rankine cycle power generator

    International Nuclear Information System (INIS)

    Tang, Hao; Wu, Huagen; Wang, Xiaolin; Xing, Ziwen

    2015-01-01

    The ORC (organic Rankine cycle) system is an effective technology to generate electricity from low temperature heat sources. The twin-screw expander is a key component that is commonly used in the small-to-medium capacity ORC system to convert thermal energy into work. In this paper, the performance of a twin-screw expander is theoretically and experimentally studied. A mathematical model is developed and subsequently validated using experimental data. The effect of several important factors including expander speed, suction pressure and inlet superheat on the expander performance is investigated. Results indicate that the expander speed and suction pressure have large influences on the expander performance, while the inlet superheat has relatively small effect. The isentropic efficiency of the expander decreases from 0.88 to 0.6 and the expander volumetric efficiency decreases from 0.88 to 0.7 as the expander rotational speed increases from 1250 to 6000 rpm. The results further show that the expander volumetric efficiency decreases from 0.91 to 0.85 as the expander suction pressure increases from 0.33 to 0.47 MPa. Furthermore, the energy conversion efficiency of the studied ORC system using the twin-screw expander is as high as 7.5% under the site conditions. - Highlights: • Performance of a twin-screw expander used in an ORC (organic Rankine cycle) system was studied. • A thermodynamic model was developed for this purpose and experimentally validated. • Effect of several key factors on the expander performance was investigated. • Suction pressure has a large influence on the expander performance. • Twin-screw expanders can be operated with a wide range of heat source temperatures.

  16. In vitro catheter and sorbent-based method for clearance of radiocontrast material during cerebral interventions

    Energy Technology Data Exchange (ETDEWEB)

    Angheloiu, George O., E-mail: goangheloiu@drmc.org [Heart and Vascular Institute, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Department of Cardiology, Dubois Regional Medical Center, Dubois, PA (United States); Hänscheid, Heribert; Reiners, Christoph [Department of Nuclear Medicine, University of Würzburg, Würzburg (Germany); Anderson, William D. [Cardiology Department, Exempla Healthcare, Denver, CO (United States); Kellum, John A. [CRISMA Center, Department of Critical Care Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2013-07-15

    Background: Contrast-induced acute kidney injury is a severe condition resulting from the use of radiology contrast in patients with predisposing factors. Hypothesis: We hypothesized that a novel system including a device containing polymer resin sorbent beads and a custom-made suctioning catheter could efficiently remove contrast from an in vitro novel model of circulatory system (MOCS) mimicking the cerebral circulation. Methods: A custom-made catheter was built and optimized for cerebral venous approach. The efficiency of a system made of a polymer resin sorbent beads column (CST 401, Cytosorbents) and this particular catheter was tested in the MOCS running a solution composed of 0.9% saline and radio-contrast. During two series of 18 cycles of first-pass experiments we assessed the catheter's suctioning efficiency and the system's ability to clear radio-contrast injected into the MOCS's cerebral arterial segment. We also assessed the functioning and reliability of the MOCS. Results: Mean suctioning efficiency of the catheter was 84% ± 24%. The polymer sorbent column contrast removal rate was initially 96% and gradually decreased with subsequent cycles in a linear fashion during an experiment lasting approximately 90 minutes. The MOCS had a reliability of 0.9946×min{sup −1} where 1 × min{sup −1} was the optimum value. Conclusion: A system including a polymer resin sorbent beads column and a custom-made suctioning catheter had an excellent initial efficiency in quickly removing contrast from an artificial MOCS mimicking the cerebral circulation. MOCS is an inexpensive and relatively reliable custom-made system that can be used for training or testing purposes.

  17. Efficacy of a Novel Narrow Knife with Water Jet Function for Colorectal Endoscopic Submucosal Dissection.

    Science.gov (United States)

    Yoshida, Naohisa; Toyonaga, Takashi; Murakami, Takaaki; Hirose, Ryohei; Ogiso, Kiyoshi; Inada, Yutaka; Rani, Rafiz Abdul; Naito, Yuji; Kishimoto, Mitsuo; Ohara, Yoshiko; Azuma, Takeshi; Itoh, Yoshito

    2017-01-01

    With respect to the knife's design in colorectal endoscopic submucosal dissection (ESD), diameter, water jet function, and electric power are important because these relate to efficient dissection. In this study, we analyzed a novel, narrow ball tip-typed ESD knife with water jet function (Flush knife BT-S, diameter: 2.2 mm, length: 2000 mm, Fujifilm Co., Tokyo, Japan) compared to a regular diameter knife (Flush knife BT, diameter: 2.6 mm, length: 1800 mm). In laboratory and clinical research, electric power, knife insertion time, vacuum/suction amount with knife in the endoscopic channel, and water jet function were analyzed. We used a knife 2.0 mm long for BT-S and BT knives. The BT-S showed faster mean knife insertion time (sec) and better vacuum amount (ml/min) compared to the BT (insertion time: 16.7 versus 21.6, p knife insertion. Suction under knife happened 59% (23/39) and suction of fluid could be done in 100%. Our study showed that the narrow knife allows significantly faster knife insertion, better vacuum function, and effective clinical results.

  18. Non-similar solutions for unsteady flow over a yawed cylinder with non-uniform mass transfer through a slot

    Directory of Open Access Journals (Sweden)

    G. Revathi

    2014-12-01

    Full Text Available Non-similar solutions are found numerically to a system of coupled non-linear partial differential equations indicating, unsteady laminar water boundary layer flow over yawed cylinder using implicit finite difference scheme along with Quasi-linearization technique. The fluid properties such as viscosity and Prandtl number are considered as an inverse function of temperature. Unsteadiness is caused by upstream velocity in and directions and non-uniform mass transfer (suction/injection which is applied through slot on the surface of the geometry. The effect of yaw angle, variable fluid properties and non-uniform mass transfer on skin friction and heat transfer coefficients is analyzed. It is found that non-uniform slot suction and downstream movement of the slot cause the point of vanishing skin friction moves downstream, but non-uniform slot injection produces the opposite result of that corresponding to the suction case. When the yaw angle increases, both the skin friction coefficient in the – direction and the heat transfer coefficient decrease but the skin friction coefficient in the – direction increases for all times. The effect of the yaw angle is very little on the point of vanishing skin friction.

  19. International joint research project of venture seeds excavating type in fiscal 1999 (revised) - venture seeds No.3. Report on achievements in developing bump forming technologies for high-density semiconductor connection; 1999 nendo (hosei) venture seeds hakkutsugata kokusai kyodo kenkyu jigyo - venture seeds No.3. Komitsudo handotai setsuzokuyo bump gata keisei gijutsu kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Development has been advanced on a new flip chip technology with high efficiency and reliability to mount on lead frames and substrates the semiconductor devices that have been made higher in density and function and smaller in size. Specifically, discussions were given on a bump forming technology using micro balls with high accuracy and sphericity. With this technology, bumps are formed with high accuracy and efficiency by transferring and bonding the micro balls onto electrodes. Activities were taken in the following five areas: 1) discussions on the micro ball arranging technology, 2) optimization and evaluation on bed films, 3) manufacture and evaluation on micro balls, 4) overall evaluation and improvement discussion on quality and cost, and 5) analysis of thermal stress on soldered balls. In Item 1), micro balls are transferred onto pads after removing excess balls by sucking them into a suction head while having the micro balls float in a container by means of vibration. The suction arrangement plates were discussed and the suction system was optimized, whereas it was verified that balls with diameter of 100 {mu} m can be transferred and bonded onto pads of the chips without excess and insufficiency. (NEDO)

  20. Follow-up durability measurements and mitigation-performance improvement tests in 38 Eastern Pennsylvania houses having indoor radon-reduction systems. Final report, Oct 89-Feb 90

    International Nuclear Information System (INIS)

    Findlay, W.O.; Robertson, A.; Scott, A.G.

    1991-03-01

    The report gives results of follow-up tests in 38 difficult-to-mitigate Pennsylvania houses where indoor radon reduction systems had been installed 2 to 4 years earlier. Objectives were to assess system durability, methods for improving performance, and methods for reducing installation and operating costs. The durability tests indicated that the 38 systems have not experienced any significant degradation in indoor radon levels or in system flows/suctions, except in 6 houses where system fans failed, and in houses where homeowners turned off the systems. Tests to improve performance indicated that nearly all of the elevated residual radon levels are due to re-entrainment back into the house of very-high-radon exhaust gas from the soil depressurization systems, and to radon release from well water. Tests to reduce system costs showed that premitigation sub-slab suction field measurements can help prevent installation of too many suction pipes when communication is good, but suggest a need for too many pipes when communication is poor. Soil depressurization fans could not be turned down to the extent expected in some systems that were over-designed. Between 6 and 42% of the exhausted air was withdrawn from the house