WorldWideScience

Sample records for successful target clearance

  1. Maximizing in vivo target clearance by design of pH-dependent target binding antibodies with altered affinity to FcRn.

    Science.gov (United States)

    Yang, Danlin; Giragossian, Craig; Castellano, Steven; Lasaro, Marcio; Xiao, Haiguang; Saraf, Himanshu; Hess Kenny, Cynthia; Rybina, Irina; Huang, Zhong-Fu; Ahlberg, Jennifer; Bigwarfe, Tammy; Myzithras, Maria; Waltz, Erica; Roberts, Simon; Kroe-Barrett, Rachel; Singh, Sanjaya

    2017-10-01

    Antibodies with pH-dependent binding to both target antigens and neonatal Fc receptor (FcRn) provide an alternative tool to conventional neutralizing antibodies, particularly for therapies where reduction in antigen level is challenging due to high target burden. However, the requirements for optimal binding kinetic framework and extent of pH dependence for these antibodies to maximize target clearance from circulation are not well understood. We have identified a series of naturally-occurring high affinity antibodies with pH-dependent target binding properties. By in vivo studies in cynomolgus monkeys, we show that pH-dependent binding to the target alone is not sufficient for effective target removal from circulation, but requires Fc mutations that increase antibody binding to FcRn. Affinity-enhanced pH-dependent FcRn binding that is double-digit nM at pH 7.4 and single-digit nM at pH 6 achieved maximal target reduction when combined with similar target binding affinities in reverse pH directions. Sustained target clearance below the baseline level was achieved 3 weeks after single-dose administration at 1.5 mg/kg. Using the experimentally derived mechanistic model, we demonstrate the essential kinetic interplay between target turnover and antibody pH-dependent binding during the FcRn recycling, and identify the key components for achieving maximal target clearance. These results bridge the demand for improved patient dosing convenience with the "know-how" of therapeutic modality by design.

  2. Evaluation of serum iohexol clearance for use in predicting carboplatin clearance in cats.

    Science.gov (United States)

    Bailey, Dennis B; Rassnick, Kenneth M; Prey, Joshua D; Dykes, Nathan L

    2009-09-01

    To determine whether a glomerular filtration rate (GFR) assay based on serum iohexol clearance can be used to predict carboplatin clearance in cats. 10 cats with tumors. GFR was measured concurrently by use of plasma clearance of technetium Tc 99m-labeled diethylenetriaminepentaacetic acid ((99m)Tc-DTPA) to yield GFR(99mTc-DTPA) and serum clearance of iohexol to yield GFR(Iohexol). A single dose of carboplatin was administered IV as a bolus. Dose was calculated by use of a target value for the area under the plasma platinum concentration-versus-time curve (AUC(Target)) and estimation of platinum clearance (CL(PT)) derived from GFR(99mTc-DTPA) as follows: dose = AUC(Target) x 2.6 x GFR(99mTc-DTPA) x body weight, where AUC(Target) is 2.75 min.mg.mL(-1). Plasma platinum concentrations were measured via atomic absorption spectrophotometry. Values for GFR(99mTc-DTPA) and GFR(Iohexol) were compared by use of least-squares regression and Bland-Altman analysis. Least-squares regression was used to determine whether CL(PT) could be predicted from GFR(99mTc-DTPA) or GFR(Iohexol) (or both). GFR(99mTc-DTPA) and GFR(Iohexol) were strongly correlated (r = 0.90), but GFR(Iohexol) values were significantly larger by a factor of approximately 1.4. Platinum clearance had a significant linear relationship to GFR(99mTc-DTPA) (CL(PT) = 2.5 x GFR(99mTc-DTPA)) and to GFR(Iohexol) (CL(PT) = [1.3 x GFR(Iohexol)] + 1.4). In cats, serum iohexol clearance was an accurate predictor of CL(PT) and can be used to calculate the carboplatin dose as follows: dose = AUC(Target) x ([1.3 x GFR(Iohexol)] + 1.4) x body weight.

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  4. Experience and lessons learnt from clearance in Germany

    International Nuclear Information System (INIS)

    Thierfeldt, Stefan

    2002-01-01

    Clearance is an important corner-stone of waste management in nuclear installations in Germany. It has been practised successfully for around two decades. The importance of clearance can also be judged from the fact that it has been included detailedly in the new German Radiation Protection Ordinance. Currently, there are 19 NPPs and a number of fuel cycle installations in operation in Germany. The main waste quantities, however, arise from the dismantling of NPPs and fuel cycle installations which are currently in decommissioning. As most of the decommissioning projects are targeted for early dismantling instead of safe enclosure, there is already considerable experience with the application of clearance procedures and verification of clearance levels. The German waste management strategy is governed by two options: Clearance of the material (after decontamination and release measurement). After clearance, the material is no longer regarded as radioactive in a legal sense. Final disposal of the material as radioactive waste in a deep geological repository (no near-surface disposal facilities exist or are planned in Germany). A deep geological repository is planned to be operable around 2030. Stefan Thierfeldt described German clearance requirements and lessons learned from their application to decommissioning of power reactors. The great majority of the waste was in fact recycled, although the costs were dominated by the small fraction that had to be disposed of as radioactive waste. Among the lessons learned from the German experience were some revealing insights into the public perception of both clearance and of recycling of material from decommissioning of a nuclear installation

  5. Improvement in Creatinine Clearance after Open Heart Surgery in Infants as an Early Indicator of Surgical Success.

    Science.gov (United States)

    Dagan, Amit; Dagan, Ovadia

    2016-12-01

    Early surgical correction of congenital heart malformations in neonates and small infants may be complicated by acute kidney injury (AKI), which is associated with higher morbidity and mortality rates, especially in patients who require dialysis. Glomerular filtration rate (GFR) is considered the best measurement of renal function which, in neonates and infants, is highly dependent on heart function. To determine whether measurements of creatinine clearance after open heart surgery in neonates and young infants can serve as an early indicator of surgical success or AKI. We conducted a prospective observational study in 19 neonates and small infants (body weight creatinine clearance and albumin excretion was performed before and during surgery and four times during 48 hours after surgery. Mean creatinine clearance was lowest during surgery (25.2 ± 4. ml/min/1.73 m2) and increased significantly in the first 16 hours post-surgery (45.7 ± 6.3 ml/min/1.73 m2). A similar pattern was noted for urine albumin which was highest during surgery (203 ± 31 µg/min) and lowest (93 ± 20 µg/min) 48 hours post-surgery. AKI occurred in four patients, and two patients even required dialysis. All six showed a decline in creatinine clearance and an increase in urine albumin between 8 and 16 hours post-surgery. In neonates and small infants undergoing open heart surgery, a significant improvement in creatinine clearance in the first 16 hours postoperatively is indicative of a good surgical outcome. This finding has important implications for the early evaluation and treatment of patients in the intensive care unit on the first day post-surgery.

  6. Recent activities on clearance in IAEA and clearance automatic laser inspection system (CLALIS)

    International Nuclear Information System (INIS)

    Hattori, Takatoshi; Sasaki, Michiya

    2005-01-01

    Exemption levels for bulk amounts of materials have been described in RS-G-1.7 published as a safety guide in IAEA on August 2004. In Japan, the Nuclear Safety Commission adopted the RS-G-1.7 values as Japanese clearance levels after the careful review of dose assessment results. After completing revises of regulatory laws in relation to clearance level, solid wastes from decommissioning and operating nuclear power plants will be targets of clearance inspection. In CRIEPI, Clearance Automatic Laser Inspection System (CLALIS) has been developed, which can give high reliability and objectivity to the measurement data. The CLALIS is a new monitoring system coupling with 3D laser shape measurement, Monte-Carlo calculation and gamma measurement techniques, which can keep a high accuracy in the measurement data using an automatic correction technique for self-shielding effects of metal waste itself and is expected to apply as a practical use in actual clearance inspections. (author)

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Research Consortia CF Biomarker Consortium CFTR 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study Services Working With the TDN Tools and Resources ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center ...

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study ...

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from ...

  12. EVALUATION OF CRITICAL SUCCESS FACTORS THROUGH THE USE OF MIND MAP IN THE LOGISTIC PROCESS OF A CUSTOMS CLEARANCE COMMISSIONER IN A BRAZILIAN COMPANY

    Directory of Open Access Journals (Sweden)

    Jadir Perpétuo dos Santos

    2015-06-01

    Full Text Available The objective of this work is to present, by the means of Mind Map, the critical success factors of the project developed by a Customs Clearance Commissioner. The research methodology used is exploratory, through interviews, based on the Delphi technique to obtain consensus, combined with the exploratory-descriptive analysis of a case study. The case study was observed in an unsystematic way, with an unstructured questionnaire. The conclusions presented here reveal two critical success factors in the import of parts and pieces, that are compounds of machines and industrial equipment, showing that the Mind Map is an innovative application for managing logistics projects, enabling better visualization of critical points, which brings improvements in the planning of activities for areas of knowledge, applied to the deployment project developed by the Customs Clearance Commissioner.

  13. Degradability and Clearance of Silicon, Organosilica, Silsesquioxane, Silica Mixed Oxide, and Mesoporous Silica Nanoparticles

    KAUST Repository

    Croissant, Jonas G.

    2017-01-13

    The biorelated degradability and clearance of siliceous nanomaterials have been questioned worldwide, since they are crucial prerequisites for the successful translation in clinics. Typically, the degradability and biocompatibility of mesoporous silica nanoparticles (MSNs) have been an ongoing discussion in research circles. The reason for such a concern is that approved pharmaceutical products must not accumulate in the human body, to prevent severe and unpredictable side-effects. Here, the biorelated degradability and clearance of silicon and silica nanoparticles (NPs) are comprehensively summarized. The influence of the size, morphology, surface area, pore size, and surface functional groups, to name a few, on the degradability of silicon and silica NPs is described. The noncovalent organic doping of silica and the covalent incorporation of either hydrolytically stable or redox- and enzymatically cleavable silsesquioxanes is then described for organosilica, bridged silsesquioxane (BS), and periodic mesoporous organosilica (PMO) NPs. Inorganically doped silica particles such as calcium-, iron-, manganese-, and zirconium-doped NPs, also have radically different hydrolytic stabilities. To conclude, the degradability and clearance timelines of various siliceous nanomaterials are compared and it is highlighted that researchers can select a specific nanomaterial in this large family according to the targeted applications and the required clearance kinetics.

  14. Applicability of Clearance Automatic Laser Inspection System to Clearance Measurement of Concrete Segments

    International Nuclear Information System (INIS)

    Sasaki, M.; Ogino, H.; Hattori, T.

    2009-01-01

    In the decommissioning of a nuclear power plant, large amounts of metal scrap and concrete segments require disposal when dismantling the nuclear reactor and surrounding facilities. When their activity level is negligible or sufficiently small, they can be regarded as general industrial waste. To distinguish between radioactive and nonradioactive materials, the clearance level for each radionuclide has been determined in units of activity concentration. These clearance levels are indicated in the International Atomic Energy Agency (IAEA) Safety Standards Series No. RS-G-1.7. The Japanese regulatory authority decided in 2005 to adopt the values given in RS-G-1.7 as clearance levels in legislation. Recently, a Clearance Automatic Laser Inspection System (CLALIS) has been developed utilizing gamma-ray measurement, automatic laser shape measurement and Monte Carlo calculation. CLALIS comprises four laser scanners and eight large plastic scintillation detectors surrounded by a 5-cm-thick lead shield. Using three-dimensional (3D) laser scanning, a measurement target, which is placed on the measuring tray, is represented as a dot image. The dot image is converted into voxels after noise removal, and is written in MCNP (A General Monte Carlo N-Particle Transport Code System) input files. When the gamma-ray measurement is carried out, the MCNP calculations are also carried out to obtain the calibration factor and background (BG) correction factors. For the clearance measurement of concrete segments, the effect of gamma-rays from natural radionuclides in the measurement target, such as K-40 and the radioactive decay products of Th-232 and U-238, should be taken into account to ensure adequate waste management. Since NE102A plastic scintillation detectors are used for gamma-ray measurement in CLALIS, it is impossible to distinguish between the count rates of natural radionuclides and contaminants on the basis of gamma-ray energy information. To overcome this problem, the

  15. Low ground clearance vehicle detection and warning.

    Science.gov (United States)

    2015-06-01

    A Low Ground Clearance Vehicle Detection : System (LGCVDS) determines if a commercial : motor vehicle can successfully clear a highwayrail : grade crossing and notifies the driver when : his or her vehicle cannot safely traverse the : crossing. That ...

  16. Comparison of renal clearance of 99mTc-DTPA and inulin, 131I-hippurate and PAH as well as of the creatinine clearance in Wistar rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Order of magnitude and standard deviation of 99m Tc-DTPA and 131 I-hippurate slope clearance were analyzed successively in 56 male Wistar rats. The clearance of 99m Tc-DTPA was 17.4 ± 3.43 μl · s -1 (100 g b-w) -1 , of 131 I-hippurate 34.3 ± 7.21 μl · s -1 (100 g b-w) -1 . In 17 rats inulin and PAH clearances were analyzed by steady state method with permanent infusion and 3 to 4 urine collection periods 3 days later. The endogeneous creatinine clearance was determined within the same periods. The 99m Tc-DTPA slope clearance corresponded to the inulin clearance, as well as the hippurate clearance to the PAH clearance. The high filtration fraction calculated from nuclear medicine and chemical clearance methods and the low PAH extraction (42%) let suggest that PAH and hippurate are eliminated only incompletely from plasma in rat kidney and are unsuitable for determination of renal blood supply in rats. The creatinine clearance with 4.7 ± 1.38 μl · s -1 (100 g b-w) -1 was far beneath the clearance of inulin and 99m Tc-DTPA, supposing that creatinine is reabsorbed tubularly in part and the creatinine clearance can not be used for valuation of the GFR in rats. However, for this the 99m Tc-DTPA clearance in Wistar rats seems to be well suited. (author)

  17. Lung mucociliary clearance

    International Nuclear Information System (INIS)

    Mortensen, J.; Lange, P.; Nyboe, J.; Groth, S.

    1994-01-01

    The aim of this study was to establish reference values for mucociliary clearance and mucociliary clearance reserve capacity as determined by β 2 -adrenergic agonist-induced increase in mucociliary clearance. We studied 62 healthy females (n=33) and males (n=29). Their ages ranged evenly between 18 and 84 years. Fifty-three of the subjects were life-long non-smokers, while nine were ex-smokers. Multiple linear regression analyses showed that mucociliary clearance was significantly faster when the radioaerosol was deposited in the central airways than when it was deposited in the peripheral airways, and faster in life-long non-smokers than in ex-smokers. There was no influence of age, and no convincing association with sex. The variation was less within than between subjects. Mean mucociliary clearance reserve capacity was 21.3% (SD: 10.0%, P 2 agonist-induced increase in lung mucociliary clearance was significantly larger (P<0.05) than the stimulation which has previously been reported in patients with asthma, bronchiectasis or cystic fibrosis. The signal-to-noise ratio of the mucociliary clearance reserve capacity in relation to measurement of baseline mucociliary clearance indicates that measurement of mucociliary clearance reserve capacity may be a more efficient means of distinguishing between ''normal'' and ''abnormal'' mucociliary clearance than single measurement of baseline mucociliary clearance. (orig.)

  18. Isotope determinations of renal clearance equivalent with physiological clearance measurements

    International Nuclear Information System (INIS)

    Junges, R.

    1983-01-01

    The concept of renal clearance in nuclear medicine describes the tubular secretion and glomerular filtration of a substance being removed from the blood plasma. The concept of clearance as used physiologically is rather wider and includes consideration of the outflow of the substances remained back in the kidneys. The present paper discusses clearance measurements as seen from a thermodynamic point of view, in which isotope clearances become equivalent with the physiological concept of clearance. In addition, it is possible to quantify each single step of the excretory function of each kidney separately. (orig.) [de

  19. Dying cell clearance and its impact on the outcome of tumor radiotherapy

    International Nuclear Information System (INIS)

    Lauber, Kirsten; Ernst, Anne; Orth, Michael; Herrmann, Martin; Belka, Claus

    2012-01-01

    The induction of tumor cell death is one of the major goals of radiotherapy and has been considered to be the central determinant of its therapeutic outcome for a long time. However, accumulating evidence suggests that the success of radiotherapy does not only derive from direct cytotoxic effects on the tumor cells alone, but instead might also depend – at least in part – on innate as well as adaptive immune responses, which can particularly target tumor cells that survive local irradiation. The clearance of dying tumor cells by phagocytic cells of the innate immune system represents a crucial step in this scenario. Dendritic cells and macrophages, which engulf, process and present dying tumor cell material to adaptive immune cells, can trigger, skew, or inhibit adaptive immune responses, respectively. In this review we summarize the current knowledge of different forms of cell death induced by ionizing radiation, the multi-step process of dying cell clearance, and its immunological consequences with special regard toward the potential exploitation of these mechanisms for the improvement of tumor radiotherapy.

  20. Comparison of the endogenous creatinine clearance, the creatinin clearance calculated without urine collection and the isotope clearance

    International Nuclear Information System (INIS)

    Mohacsi, Gabor; Lang, Jenoe; Csernay, Laszlo; Sonkodi, Sandor; Orvostudomanyi Egyetem, Szeged

    1987-01-01

    Observations are reported relating to the endogenous creatinine clearance, the Tc-99m-EDTA-complex clearance and the creatinine clearance estimated via a selected mathematical formula, with special regard to the problems of renal insufficiency and the nephrotic syndrome. The activity applied was in the range of 3.7-7.4 MBq. It was observed that measurement of the isotope clearance can also be applied to determine the endogeneous creatinine clearance in otherwise less suitable patients. A reliable result is obtained even if the renal function is restricted, but the accuracy of the method may be reduced in nephrotic syndrome cases. (author) 24 refs

  1. Lactate clearance cut off for early mortality prediction in adult sepsis and septic shock patients

    Science.gov (United States)

    Sinto, R.; Widodo, D.; Pohan, H. T.

    2018-03-01

    Previous lactate clearance cut off for early mortality prediction in sepsis and septic shock patient was determined by consensus from small sample size-study. We investigated the best lactate clearance cut off and its ability to predict early mortality in sepsis and septic shock patients. This cohort study was conducted in Intensive Care Unit of CiptoMangunkusumo Hospital in 2013. Patients’ lactate clearance and eight other resuscitationendpoints were recorded, and theoutcome was observed during the first 120 hours. The clearance cut off was determined using receiver operating characteristic (ROC) analysis, and its ability was investigated with Cox’s proportional hazard regression analysis using other resuscitation endpoints as confounders. Total of 268 subjects was included, of whom 70 (26.11%) subjects died within the first 120 hours. The area under ROC of lactate clearance to predict early mortality was 0.78 (95% % confidence interval [CI] 0.71-0.84) with best cut off was <7.5% (sensitivity and specificity 88.99% and 81.4% respectively). Compared with group achieving lactate clearance target, group not achieving lactate clearance target had to increase early mortality risk (adjusted hazard ratio 13.42; 95%CI 7.19-25.07). In conclusion, the best lactate clearance cut off as anearly mortality predictor in sepsis and septic shock patients is 7.5%.

  2. Creatinine clearance test

    Science.gov (United States)

    Serum creatinine clearance; Kidney function - creatinine clearance; Renal function - creatinine clearance ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ...

  3. Dimerization of glycoprotein Ibα is not sufficient to induce platelet clearance.

    Science.gov (United States)

    Liang, X; Syed, A K; Russell, S R; Ware, J; Li, R

    2016-02-01

    ESSENTIALS: Many anti-glycoprotein (GP)Ibα antibodies induce platelet clearance in a dimer-dependent manner. Characterization of monoclonal antibodies that bind the mechanosensitive domain (MSD) of GPIbα. An anti-MSD antibody binds two copies of GPIbα in platelets but does not induce platelet clearance. The prevailing clustering model of GPIbα signaling is incorrect or needs revision. The mechanism of platelet clearance is not clear. Many antibodies binding the membrane-distal ligand-binding domain of glycoprotein (GP)Ibα induce rapid clearance of platelets and acute thrombocytopenia, which requires the bifurcated antibody structure. It was thought that binding of these antibodies induced lateral dimerization or clustering of GPIbα in the plasma membrane, which leads to downstream signaling and platelet clearance. However, many antibodies targeting GPIbβ and GPIX, which are associated with GPIbα in the GPIb-IX complex, do not induce platelet clearance, which is in contradiction to the clustering model. To test whether dimerization or clustering of GPIbα is sufficient to transmit the signal that leads to platelet clearance. We have recently raised several mAbs targeting the mechanosensitive domain (MSD) of GPIbα. Binding of these anti-MSD antibodies was characterized with biochemical methods. Their ability to stimulate platelets and induce platelet clearance in mice was assessed. Infusion of anti-MSD antibodies does not cause thrombocytopenia in mice. These antibodies show no detectable effects on platelet activation and aggregation in vitro. Further biochemical investigation showed that the anti-MSD antibody 3D1 binds two copies of GPIbα on the platelet surface. Therefore, lateral dimerization of GPIbα induced by antibody binding is not sufficient to initiate GPIb-IX signaling and induce platelet clearance. Our results suggest that a factor other than or in addition to clustering of GPIbα is required to induce platelet clearance. © 2015 International

  4. [51Cr]EDTA plasma clearance and endogenous creatinine clearance in advanced renal insufficiency

    International Nuclear Information System (INIS)

    Svendsen, U.G.; Munck, O.; Czartoryski, A.; Stafanger, G.

    1978-01-01

    Comparison of [ 51 Cr]EDTA plasma clearance corrected for extrarenal elimination with 24 h endogenous creatinine clearance in patients with advanced renal failure showed that the corrected [ 51 Cr]EDTA clearance was lower than creatinine clearance, and thus might be a better approximation to the glomerular filtration rate in uraemic patients. The corrections cannot be used on [ 51 Cr]EDTA clearance values below the mean extrarenal clearance, averaging 3.7 ml/min. (Auth.)

  5. Exaggerated natriuresis and lithium clearance in spontaneously hypertensive rats

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Kanters, J K; Leyssac, P P

    1988-01-01

    Since hypertension is associated with changes in the handling of various cations (including sodium and lithium) across the cell membrane, the present study investigated the validity of the lithium clearance method in hypertension by comparing two measures of proximal reabsorption. Thus, fractional...... lithium excretion and transit time (TT)-occlusion time (OT; e-TT/T) were determined successively in the same spontaneously hypertensive rat (SHR, Okamoto strain). The rats were examined both before and after an acute saline load. The results show that the lithium clearance method can be used...... for the determination of proximal reabsorption in SHR. Utilizing the lithium clearance method, the changes in renal sodium handling underlying the exaggerated natriuresis were investigated in unanaesthetized catheterized rats. It was found that the exaggerated natriuresis was associated with an increased output from...

  6. Clearance and release from control - An international perspective

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2005-01-01

    (Sweden, Spain, Belgium). D and D projects should be aware of the destination of their material and the dose rate levels by which it will be monitored there or during its transport, e.g. at borders, in harbors etc. Appropriate dose rate monitors need to be installed at the exit gates of the D and D site monitoring all material leaving the premises. While there are no hard and essential reasons why clearance levels should be made equal worldwide, there is, of course, still the aspect of credibility and public opinion. Numerical differences in clearance levels between countries leave room for malevolent misinterpretation. Without looking to the reasons for those differences, anti-nuclear groups can try to present these differences as a lack of credibility and reliability of clearance. This has been tried with limited success in Germany when clearance was about to be implemented in the Radiation Protection Ordinance of 2001, and it has also been undertaken in the USA when differences emerged between clearance levels calculated in the earlier versions of the reports. In both countries the effort to bring clearance back in line again was considerable. Harmonization of clearance levels may therefore be desirable for the sake of public opinion. In summary, worldwide harmonization of clearance levels need not be a top-priority goal. Some countries with extremely restrictive clearance levels might, however, take a look to their neighbours and switch over to the existing international recommendations. This would be a major step in the harmonization process. D and D projects will, however, continue to function also if the current situation will not change: It is more important for a certain country that clearance is possible at all than that the clearance levels are identical to those of the neighbouring countries. However, the worldwide public opinion should be carefully monitored to guarantee that clearance will still be viable in the future

  7. Demonstration of a dynamic clearance seal in a rotating test facility.

    OpenAIRE

    Messenger, Andrew; Williams, Richard; Ingram, Grant; Hogg, Simon; Tibos, Stacie; Seaton, Jon; Charnley, Bernard

    2017-01-01

    The successful demonstration of the “Aerostatic Seal” in a half scale rotating facility is described in this paper. The Aerostatic seal is a novel dynamic clearance seal specifically designed for steam turbine secondary gas path applications. The seal responds to radial rotor excursions, so a reduced clearance can be maintained compared to conventional labyrinth seal without damage to the seal. This enables increased turbine performance through reduced leakage and increased tolerance of turbi...

  8. Quantitative Impact of Plasma Clearance and Down-regulation on GLP-1 Receptor Molecular Imaging.

    Science.gov (United States)

    Zhang, Liang; Thurber, Greg M

    2016-02-01

    Quantitative molecular imaging of beta cell mass (BCM) would enable early detection and treatment monitoring of type 1 diabetes. The glucagon-like peptide-1 (GLP-1) receptor is an attractive target due to its beta cell specificity and cell surface location. We quantitatively investigated the impact of plasma clearance and receptor internalization on targeting efficiency in healthy B6 mice. Four exenatide-based probes were synthesized that varied in molecular weight, binding affinity, and plasma clearance. The GLP-1 receptor internalization rate and in vivo receptor expression were quantified. Receptor internalization (54,000 receptors/cell in vivo) decreased significantly within minutes, reducing the benefit of a slower-clearing agent. The multimers and albumin binding probes had higher kidney and liver uptake, respectively. Slow plasma clearance is beneficial for GLP-1 receptor peptide therapeutics. However, for exendin-based imaging of islets, down-regulation of the GLP-1 receptor and non-specific background uptake result in a higher target-to-background ratio for fast-clearing agents.

  9. Mucociliary clearance

    DEFF Research Database (Denmark)

    Munkholm, Mathias; Mortensen, Jann

    2014-01-01

    Mucociliary clearance has long been known to be a significant innate defence mechanism against inhaled microbes and irritants. Important knowledge has been gathered regarding the anatomy and physiology of this system, and in recent years, extensive studies of the pathophysiology related to lung...... pharmacological interventions on clearance rate, to study the importance of defective mucus clearance in different lung diseases or as a diagnostic tool in the work-up of patients with recurrent airway diseases. The aim of this review is to provide an overview of the anatomy, physiology, pathophysiology...

  10. Numerical study on tip clearance effect on performance of a centrifugal compressor

    International Nuclear Information System (INIS)

    Eum, Hark Jin; Kang, Shin Kyoung

    2003-01-01

    Effect of tip leakage flow on through flow and performance of a centrifugal compressor impeller was numerically studied using CFX-TASCflow. Seven different tip clearances were used to consider the influence of tip clearance on performance. Secondary flow and loss factor were evaluated to understand the loss mechanism inside the impeller due to tip leakage flow. The calculated results were circumferentially averaged along the passage and at the impeller exit for quantitative discussion. Tip clearance effect on performance could be decomposed into inviscid and viscous components using one dimensional equation. The inviscid component is related with the specific work reduction and the viscous component is related with the additional entropy generation. Two components affected performance equally, while efficiency drop was mainly influenced by viscous loss. Performance and efficiency drop due to tip clearance were proportional to the ratio of tip clearance to exit blade height. A simple model suggested in the present study predict performance and efficiency drop quite successfully

  11. TAM receptors in apoptotic cell clearance, autoimmunity, and cancer.

    Science.gov (United States)

    Nguyen, Khanh-Quynh; Tsou, Wen-I; Kotenko, Sergei; Birge, Raymond B

    2013-08-01

    Receptor tyrosine kinases, Tyro-3, Axl and Mer, collectively designated as TAM, are involved in the clearance of apoptotic cells. TAM ligands, Gas6 and Protein S, bind to the surfaces of apoptotic cells, and at the same time, interact directly with TAM expressed on phagocytes, impacting the engulfment and clearance of apoptotic cells and debris. The well-tuned and balanced actions of TAM may affect a variety of human pathologies including autoimmunity, retinal degeneration, and cancer. This article emphasizes some of the emerging findings and mechanistic insights into TAM functions that are clinically relevant and possibly therapeutically targeted.

  12. Dysregulation of Nutrient Sensing and CLEARance in Presenilin Deficiency

    Directory of Open Access Journals (Sweden)

    Kavya Reddy

    2016-03-01

    Full Text Available Attenuated auto-lysosomal system has been associated with Alzheimer disease (AD, yet all underlying molecular mechanisms leading to this impairment are unknown. We show that the amino acid sensing of mechanistic target of rapamycin complex 1 (mTORC1 is dysregulated in cells deficient in presenilin, a protein associated with AD. In these cells, mTORC1 is constitutively tethered to lysosomal membranes, unresponsive to starvation, and inhibitory to TFEB-mediated clearance due to a reduction in Sestrin2 expression. Normalization of Sestrin2 levels through overexpression or elevation of nuclear calcium rescued mTORC1 tethering and initiated clearance. While CLEAR network attenuation in vivo results in buildup of amyloid, phospho-Tau, and neurodegeneration, presenilin-knockout fibroblasts and iPSC-derived AD human neurons fail to effectively initiate autophagy. These results propose an altered mechanism for nutrient sensing in presenilin deficiency and underline an importance of clearance pathways in the onset of AD.

  13. Development of the clearance level verification evaluation system. 2. Construction of the clearance data management system

    International Nuclear Information System (INIS)

    Kubota, Shintaro; Usui, Hideo; Kawagoshi, Hiroshi

    2014-06-01

    Clearance is defined as the removal of radioactive materials or radioactive objects within authorized practices from any further regulatory control by the regulatory body. In Japan, clearance level and a procedure for its verification has been introduced under the Laws and Regulations, and solid clearance wastes inspected by the national authority can be handled and recycled as normal wastes. The most prevalent type of wastes have generated from the dismantling of nuclear facilities, so the Japan Atomic Energy Agency (JAEA) has been developing the Clearance Level Verification Evaluation System (CLEVES) as a convenient tool. The Clearance Data Management System (CDMS), which is a part of CLEVES, has been developed to support measurement, evaluation, making and recording documents with clearance level verification. In addition, validation of the evaluation result of the CDMS was carried out by inputting the data of actual clearance activities in the JAEA. Clearance level verification is easily applied by using the CDMS for the clearance activities. (author)

  14. Calculation of the clearance requirements for the development of a hemodialysis-based wearable artificial kidney.

    Science.gov (United States)

    Kim, Dong Ki; Lee, Jung Chan; Lee, Hajeong; Joo, Kwon Wook; Oh, Kook-Hwan; Kim, Yon Su; Yoon, Hyung-Jin; Kim, Hee Chan

    2016-04-01

    Wearable artificial kidney (WAK) has been considered an alternative to standard hemodialysis (HD) for many years. Although various novel WAK systems have been recently developed for use in clinical applications, the target performance or standard dose of dialysis has not yet been determined. To calculate the appropriate clearance for a HD-based WAK system for the treatment of patients with end-stage renal disease with various dialysis conditions, a classic variable-volume two-compartment kinetic model was used to simulate an anuric patient with variable target time-averaged creatinine concentration (TAC), daily water intake volume, daily dialysis pause time, and patient body weight. A 70-kg anuric patient with a HD-based WAK system operating for 24 h required dialysis clearances of creatinine of at least 100, 50, and 25 mL/min to achieve TACs of 1.0, 2.0, and 4.0 mg/dL, respectively. The daily water intake volume did not affect the clearance required for dialysis under various conditions. As the pause time per day for the dialysis increased, higher dialysis clearances were required to maintain the target TAC. The present study provided theoretical dialysis doses for an HD-based WAK system to achieve various target TACs through relevant mathematical kinetic modeling. The theoretical results may contribute to the determination of the technical specifications required for the development of a WAK system. © 2015 The Authors. Hemodialysis International published by Wiley Periodicals, Inc. on behalf of International Society for Hemodialysis.

  15. Oxygen Tension Beneath Scleral Lenses of Different Clearances.

    Science.gov (United States)

    Giasson, Claude J; Morency, Jeanne; Melillo, Marc; Michaud, Langis

    2017-04-01

    To evaluate the relative partial pressure in oxygen (pO2) at the corneal surface under Boston XO2 scleral lenses (SL) fitted with targeted clearances of 200 and 400 μm (SL200 and SL400). During this prospective study, the right eyes of eight normal subjects were fitted with SL200 and SL400. Clearance, validated after 5 minutes of wear with an optical coherence tomograph, was used with lens thicknesses to calculate transmissibility and estimate pO2. Corneal pO2s were measured with an oxygen electrode after 5 minutes of (1) corneal exposure to calibrating gases with various pO2 or of (2) SL wear. Decays in pO2 were modeled to an exponential. Linear regression between exponent k of these decays and calibrating gas pO2s allowed for the calculation of corneal pO2 under SL. Differences between pO2s beneath SL200 and SL400 were tested with a mixed ANOVA. The estimated transmissibility based on thicknesses and clearances (239.7 ± 34.7; 434.5 ± 33.2 μm) predicted a corneal pO2 of 8.52 ± 0.51 and 6.37 ± 0.28% for SL200 and SL400. These values were close to measured pO2: 9.07 ± 0.86 and 6.19 ± 0.87% (mean ± SEM) (P time, an 18-mm scleral lens fitted with a 400-μm clearance reduces the oxygen tension available to the cornea by 30% compared to a similar lens fitted with a 200-μm clearance after 5 minutes of wear.

  16. ICP-MS analysis of lanthanide-doped nanoparticles: A quantitative and multiplexing approach to investigate biodistribution, blood clearance, and targeting

    Science.gov (United States)

    Crayton, Samuel

    The rapidly progressing field of nanotechnology promises to revolutionize healthcare in the 21st century, with applications in the prevention, diagnosis, and treatment of a wide range of diseases. However, before nanoparticulate agents can be brought into clinical use, they must first be developed, optimized, and evaluated in animal models. In the typical pre-clinical paradigm, almost all of the optimization is done at the in vitro level, with only a few select agents reaching the level of animal studies. Since only one experimental nanoparticle formulation can be investigated in a single animal, and in vivo experiments have relatively higher complexity, cost, and time requirements, it is not feasible to evaluate a very large number of agents at the in vivo stage. A major drawback of this approach, however, is that in vitro assays do not always accurately predict how a nanoparticle will perform in animal studies. Therefore, a method that allows many agents to be evaluated in a single animal subject would allow for much more efficient and predictive optimization of nanoparticles. We have found that by incorporating lanthanide tracer metals into nanoparticle formulations, we are successfully able to use inductively coupled plasma mass spectrometry (ICP-MS) to quantitatively determine a nanoparticle's blood clearance kinetics, biodistribution, and tumor delivery. This approach was applied to evaluate both passive and active tumor targeting, as well as metabolically directed targeting of nanoparticles to low pH tumor microenvironments. Importantly, we found that these in vivo measurements could be made for many nanoparticle formulations simultaneously, in single animals, due to the high-order multiplexing capability of mass spectrometry. This approach allowed for efficient and reproducible comparison of performance between different nanoparticle formulations, by eliminating the effects of subject-to-subject variability. In the future, we envision that this "higher

  17. Exercise increases the lung clearance of inhaled Tc-99m DTPA

    International Nuclear Information System (INIS)

    Meignan, M.; Rosso, J.; Cinotti, L.; Galle, P.

    1985-01-01

    It has been suggested that blood flow have little effect on the lung clearance of Tc-99m DTPA which depends on the alveolar distension. However an increase of pulmonary blood flow, induces a recruitment of new vascular areas which can enhance this clearance. To assess this hypothesis the pulmonary apical and basal clearances of a sumicronic aerosol of Tc-99m DTPA were studied at rest and at exercise in seven non smoking volunteers in upright posture. As a matter of fact exercising upright is known to increase primarily the apical blood flow. After inhalation the subjects were seated on a bicycle their back against a gamma camera which was linked to a computer. The lung radioactivity was registered successively during a resting and an exercising period. At rest there was a gradient of clearance from the apex to the base of the lung, the apical clearance being significantly higher. At exercise (50 Watts, 60 c. min /sup -1/, 7 min.) this regional gradient was enhanced by a large and significant increase of the apical clearances (0.0340 min /sup -1/ +-0.0063 SD versus 0.00183 min /sup -1/ +- 0.074 SD at rest, n = 7, p < 0.01). By contrast the changes of the basal clearances were slight and unsignificant (0.0146 min /sup -1/ +- 0.0062 SD versus 0.0140 min /sup -1/ +- 0.0082 SD). Since exercise induces little distension of the apical alveoli but drastically enhances the apical blood flow, the observed increase of the apical lung clearance could be primarily attributed to the recruitment of new capillaries induced by exercise in the apices. This led to an increase of the surface area permeability product

  18. Further training in the fields of radiological characterisation and clearance

    International Nuclear Information System (INIS)

    Bothe, M.; Feinhals, J.; Neukaeter, E.

    2016-01-01

    Radiological characterisation and clearance require specific knowledge and skills. Targeted further training of the staff is one possibility to get this knowledge and skills. A modular concept was established, which allows adaption to specific requests of the institution and state of knowledge and skills of participants. The modules have following focuses: ''radiological characterisation and clearance'', ''sampling'' and ''measurement and sampling plans'' and consist half-and-half of lectures and group works. In group works participants apply new knowledge to examples of the installation or simulated scenarios and afterwards they present and discuss the results. This concept was carried out for different institutions and is planned for some more.

  19. Impairment of paravascular clearance pathways in the aging brain.

    Science.gov (United States)

    Kress, Benjamin T; Iliff, Jeffrey J; Xia, Maosheng; Wang, Minghuan; Wei, Helen S; Zeppenfeld, Douglas; Xie, Lulu; Kang, Hongyi; Xu, Qiwu; Liew, Jason A; Plog, Benjamin A; Ding, Fengfei; Deane, Rashid; Nedergaard, Maiken

    2014-12-01

    In the brain, protein waste removal is partly performed by paravascular pathways that facilitate convective exchange of water and soluble contents between cerebrospinal fluid (CSF) and interstitial fluid (ISF). Several lines of evidence suggest that bulk flow drainage via the glymphatic system is driven by cerebrovascular pulsation, and is dependent on astroglial water channels that line paravascular CSF pathways. The objective of this study was to evaluate whether the efficiency of CSF-ISF exchange and interstitial solute clearance is impaired in the aging brain. CSF-ISF exchange was evaluated by in vivo and ex vivo fluorescence microscopy and interstitial solute clearance was evaluated by radiotracer clearance assays in young (2-3 months), middle-aged (10-12 months), and old (18-20 months) wild-type mice. The relationship between age-related changes in the expression of the astrocytic water channel aquaporin-4 (AQP4) and changes in glymphatic pathway function was evaluated by immunofluorescence. Advancing age was associated with a dramatic decline in the efficiency of exchange between the subarachnoid CSF and the brain parenchyma. Relative to the young, clearance of intraparenchymally injected amyloid-β was impaired by 40% in the old mice. A 27% reduction in the vessel wall pulsatility of intracortical arterioles and widespread loss of perivascular AQP4 polarization along the penetrating arteries accompanied the decline in CSF-ISF exchange. We propose that impaired glymphatic clearance contributes to cognitive decline among the elderly and may represent a novel therapeutic target for the treatment of neurodegenerative diseases associated with accumulation of misfolded protein aggregates. © 2014 American Neurological Association.

  20. Generic clearance values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2009-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document 'Safety Reports Series Nr 44' of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (author)

  1. Generic Clearance Values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2010-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on the one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document Safety Reports Series 44 of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (authors) [es

  2. Adalimumab Dose Tapering in Psoriasis: Predictive Factors for Maintenance of Complete Clearance.

    Science.gov (United States)

    Hansel, Katharina; Bianchi, Leonardo; Lanza, Francesco; Bini, Vittorio; Stingeni, Luca

    2017-03-10

    Psoriasis can be managed successfully with long-term biologics. Real-life clinical practice may require dose tapering as a therapeutic option to reduce the risk of drug-exposure and to increase cost-effectiveness. The responsiveness to extended intervals between adalimumab doses and the possible predictive factors of maintenance of complete clearance were studied in a retrospective 7-year single-centre analysis. Thirty patients who achieved complete clearance with adalimumab underwent dose tapering, progressively extending between-dose intervals (to 21-28 days). Sixty percent of subjects (group A) maintained complete clearance, whereas 40.0% (group B) relapsed and were switched back to the standard dosage to re-achieve complete clearance. Body mass index (BMI) and time to achieve Psoriasis Area Severity Index (PASI-100) with adalimumab standard treatment before dose tapering were significantly lower in group A than in group B (multi-variate Cox regression: p < 0.05, Kaplan-Meier analysis: p < 0.001, respectively). This study suggests that patients with lower BMI and shorter time to achieve PASI-100 with adalimumab standard dose were significantly more likely to be candidates for dose tapering.

  3. Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center

    Science.gov (United States)

    Woike, Mark R.; Roeder, James W.; Hughes, Christopher E.; Bencic, Timothy J.

    2009-01-01

    The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high-temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short-range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a benchtop calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.

  4. Ginsenoside compound K promotes β-amyloid peptide clearance in primary astrocytes via autophagy enhancement.

    Science.gov (United States)

    Guo, Jinhui; Chang, Li; Zhang, Xin; Pei, Sujuan; Yu, Meishuang; Gao, Jianlian

    2014-10-01

    The aim of the present study was to investigate the effect of ginsenoside compound K on β-amyloid (Aβ) peptide clearance in primary astrocytes. Aβ degradation in primary astrocytes was determined using an intracellular Aβ clearance assay. Aggregated LC3 in astrocyte cells, which is a marker for the level of autophagy, was detected using laser scanning confocal microscope. The effect of compound K on the mammalian target of rapamycin (mTOR)/autophagy pathway was determined using western blot analysis, and an enzyme-linked immunosorbent assay was used for Aβ detection. The results demonstrated that compound K promoted the clearance of Aβ and enhanced autophagy in primary astrocytes. In addition, it was found that phosphorylation of mTOR was inhibited by compound K, which may have contributed to the enhanced autophagy. In conclusion, compound K promotes Aβ clearance by enhancing autophagy via the mTOR signaling pathway in primary astrocytes.

  5. Degradability and Clearance of Silicon, Organosilica, Silsesquioxane, Silica Mixed Oxide, and Mesoporous Silica Nanoparticles

    KAUST Repository

    Croissant, Jonas G.; Fatieiev, Yevhen; Khashab, Niveen M.

    2017-01-01

    The biorelated degradability and clearance of siliceous nanomaterials have been questioned worldwide, since they are crucial prerequisites for the successful translation in clinics. Typically, the degradability and biocompatibility of mesoporous

  6. Optimization of protein and peptide drugs based on the mechanisms of kidney clearance.

    Science.gov (United States)

    Huang, Jiaguo; Wu, Huizi

    2018-05-30

    Development of proteins and peptides into drugs has been considered as a promising strategy to target certain diseases. However, only few proteins and peptides has been approved as new drugs into the market each year. One major problem is that proteins and peptides often exhibit short plasma half-life times, which limits the application for their clinical use. In most cases a short half-life time is not effective to deliver sufficient amount of drugs to the target organs and tissues, which is generally caused by fast renal clearance and low plasma stability due to proteolytic degradation during systemic circulation, because the most common clearance pathway of small proteins and peptides is through glomerular filtration by the kidneys. In this review, enzymatic degradation of proteins and peptides were discussed. Furthermore, several approaches to lengthen the half-life of peptides and proteins drugs based on the unique structures of glomerular capillary wall and the mechanisms of glomerular filtration were summarized, such as increasing the size and hydrodynamic diameter; increasing the negative charge to delay the filtration; increasing plasma protein binding to decrease plasma clearance. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Treatments and Therapies Airway Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. ... or caregiver. Older kids and adults can choose ACTs that they can do on their own. Share ...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy ... clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. Most are easy to ...

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage ... LEGACY GIFT Sponsor a Participant CF Climb CF Cycle for Life Great Strides Xtreme Hike Participate In ...

  11. Predicting success of oligomerized pool engineering (OPEN for zinc finger target site sequences

    Directory of Open Access Journals (Sweden)

    Goodwin Mathew J

    2010-11-01

    Full Text Available Abstract Background Precise and efficient methods for gene targeting are critical for detailed functional analysis of genomes and regulatory networks and for potentially improving the efficacy and safety of gene therapies. Oligomerized Pool ENgineering (OPEN is a recently developed method for engineering C2H2 zinc finger proteins (ZFPs designed to bind specific DNA sequences with high affinity and specificity in vivo. Because generation of ZFPs using OPEN requires considerable effort, a computational method for identifying the sites in any given gene that are most likely to be successfully targeted by this method is desirable. Results Analysis of the base composition of experimentally validated ZFP target sites identified important constraints on the DNA sequence space that can be effectively targeted using OPEN. Using alternate encodings to represent ZFP target sites, we implemented Naïve Bayes and Support Vector Machine classifiers capable of distinguishing "active" targets, i.e., ZFP binding sites that can be targeted with a high rate of success, from those that are "inactive" or poor targets for ZFPs generated using current OPEN technologies. When evaluated using leave-one-out cross-validation on a dataset of 135 experimentally validated ZFP target sites, the best Naïve Bayes classifier, designated ZiFOpT, achieved overall accuracy of 87% and specificity+ of 90%, with an ROC AUC of 0.89. When challenged with a completely independent test set of 140 newly validated ZFP target sites, ZiFOpT performance was comparable in terms of overall accuracy (88% and specificity+ (92%, but with reduced ROC AUC (0.77. Users can rank potentially active ZFP target sites using a confidence score derived from the posterior probability returned by ZiFOpT. Conclusion ZiFOpT, a machine learning classifier trained to identify DNA sequences amenable for targeting by OPEN-generated zinc finger arrays, can guide users to target sites that are most likely to function

  12. Optimization Based Clearance of Flight Control Laws A Civil Aircraft Application

    CERN Document Server

    Hansson, Anders; Puyou, Guilhem

    2012-01-01

    This book summarizes the main achievements of the EC funded 6th Framework Program project COFCLUO – Clearance of Flight Control Laws Using Optimization. This project successfully contributed to the achievement of a top-level objective to meet society’s needs for a more efficient, safer and environmentally friendly air transport by providing new techniques and tools for the clearance of flight control laws. This is an important part of the certification and qualification process of an aircraft – a costly and time-consuming process for the aeronautical industry.   The overall objective of the COFCLUO project was to develop and apply optimization techniques to the clearance of flight control laws in order to improve efficiency and reliability. In the book, the new techniques are explained and benchmarked against traditional techniques currently used by the industry. The new techniques build on mathematical criteria derived from the certification and qualification requirements together with suitable models...

  13. Study on clearance system

    International Nuclear Information System (INIS)

    Onishi, Yuko; Miura, Hiroshi; Kawasaki, Satoru

    2011-01-01

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports NISA on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In reactor facilities, the bulk measurement technique or the statistical sampling measurement technique may be applied to large scale objects or concrete walls. In this study, the criteria of those techniques were examined. In uranium processing facilities, it is important to confirm surface state of the object in case of detecting alpha rays. The result of the examination about the influence of the surface rust in the uranium clearance measurement by the alpha ray measurement showed that the pollution was distributed in rust layer uniformly. This result will be reflected to the revision of the Ministerial Ordinance on Clearance in 2011FY. To develop a manual for unexpected incidents, the response procedure for an unexpected incident was prepared, including a response system. (author)

  14. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast ... Facebook Twitter ...

  15. Diesel Engine Valve Clearance Detection Using Acoustic Emission

    Directory of Open Access Journals (Sweden)

    Fathi Elamin

    2010-01-01

    Full Text Available This paper investigated, using experimental method, the suitability of acoustic emission (AE technique for the condition monitoring of diesel engine valve faults. The clearance fault was adjusted experimentally in an exhaust valve and successfully detected and diagnosed in a Ford FSD 425 four-cylinder, four-stroke, in-line OHV, direct injection diesel engine. The effect of faulty exhaust valve clearance on engine performance was monitored and the difference between the healthy and faulty engine was observed from the recorded AE signals. The measured results from this technique show that using only time domain and frequency domain analysis of acoustic emission signals can give a superior measure of engine condition. This concludes that acoustic emission is a powerful and reliable method of detection and diagnosis of the faults in diesel engines and this is considered to be a unique approach to condition monitoring of valve performance.

  16. Dual Target Search is Neither Purely Simultaneous nor Purely Successive.

    Science.gov (United States)

    Cave, Kyle R; Menneer, Tamaryn; Nomani, Mohammad S; Stroud, Michael J; Donnelly, Nick

    2017-08-31

    Previous research shows that visual search for two different targets is less efficient than search for a single target. Stroud, Menneer, Cave and Donnelly (2012) concluded that two target colours are represented separately based on modeling the fixation patterns. Although those analyses provide evidence for two separate target representations, they do not show whether participants search simultaneously for both targets, or first search for one target and then the other. Some studies suggest that multiple target representations are simultaneously active, while others indicate that search can be voluntarily simultaneous, or switching, or a mixture of both. Stroud et al.'s participants were not explicitly instructed to use any particular strategy. These data were revisited to determine which strategy was employed. Each fixated item was categorised according to whether its colour was more similar to one target or the other. Once an item similar to one target is fixated, the next fixated item is more likely to be similar to that target than the other, showing that at a given moment during search, one target is generally favoured. However, the search for one target is not completed before search for the other begins. Instead, there are often short runs of one or two fixations to distractors similar to one target, with each run followed by a switch to the other target. Thus, the results suggest that one target is more highly weighted than the other at any given time, but not to the extent that search is purely successive.

  17. Semen amyloids participate in spermatozoa selection and clearance.

    Science.gov (United States)

    Roan, Nadia R; Sandi-Monroy, Nathallie; Kohgadai, Nargis; Usmani, Shariq M; Hamil, Katherine G; Neidleman, Jason; Montano, Mauricio; Ständker, Ludger; Röcker, Annika; Cavrois, Marielle; Rosen, Jared; Marson, Kara; Smith, James F; Pilcher, Christopher D; Gagsteiger, Friedrich; Sakk, Olena; O'Rand, Michael; Lishko, Polina V; Kirchhoff, Frank; Münch, Jan; Greene, Warner C

    2017-06-27

    Unlike other human biological fluids, semen contains multiple types of amyloid fibrils in the absence of disease. These fibrils enhance HIV infection by promoting viral fusion to cellular targets, but their natural function remained unknown. The similarities shared between HIV fusion to host cell and sperm fusion to oocyte led us to examine whether these fibrils promote fertilization. Surprisingly, the fibrils inhibited fertilization by immobilizing sperm. Interestingly, however, this immobilization facilitated uptake and clearance of sperm by macrophages, which are known to infiltrate the female reproductive tract (FRT) following semen exposure. In the presence of semen fibrils, damaged and apoptotic sperm were more rapidly phagocytosed than healthy ones, suggesting that deposition of semen fibrils in the lower FRT facilitates clearance of poor-quality sperm. Our findings suggest that amyloid fibrils in semen may play a role in reproduction by participating in sperm selection and facilitating the rapid removal of sperm antigens.

  18. Dual Targeting of Amyloid-beta Clearance and Neuroinflammation as a Novel Therapeutic Approach against Alzheimer's Disease

    Science.gov (United States)

    Batarseh, Yazan S.

    Amyloid-beta (Abeta) cascade hypothesis suggests that Alzheimer's disease (AD) is related to an imbalance between the production and clearance of Abeta peptide. Sporadic AD has been related to faulty clearance of Abeta. Accumulation of Abeta oligomers (Abetao) has been linked to several downstream toxic effects including neuroinflammation, synaptic loss, and cellular death. Abeta transport across the blood-brain barrier (BBB) is one of the primary pathways for reducing Abeta load in the brain, which work hand in hand with other parenchymal mechanisms to reduce Abeta levels including intra and extracellular degradation by a family of Abeta degrading enzymes. Established AD drugs, such as the cholinesterase inhibitor donepezil, have been reported to have several additional non-cholinergic effects that alter Abeta pathology; reduce Abeta load, anti-inflammatory response, and attenuate synaptic loss. However, their limited effect only lead to minor improvements in AD symptoms without improving the prognosis of the disease. The lack of effective medical treatment for AD led to several studies focusing on establishing new therapeutic approaches to reduce Abeta pathology. We aimed to identify and characterize natural products that are capable of enhancing the BBB clearance of Abeta in addition to reducing neuroinflammation. Our first project was to investigate the role of oleocanthal (one of the active ingredients in extra-virgin olive oil; EVOO) on attenuating Abeta toxic effects on neurons and astrocytes. We developed Abeta oligomers (Abetao) induced inflammatory environment by exposing neurons and astrocytes to accumulative doses of Abetao to investigate oleocanthal effect on modulating Abetao pathological changes in neurons and astrocytes. Our findings demonstrated oleocanthal prevented Abetao-induced synaptic proteins, SNAP-25 and PSD-95, down-regulation in neurons, attenuated Abetao-induced inflammation, and restored glutamine transporter (GLT1) and glucose

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... and Their Families When There's More Than One Person With CF in the Same School Daily Life ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Team Your cystic fibrosis care team includes a group of CF health care professionals who partner with ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  1. Human-in-the-Loop Assessment of Alternative Clearances in Interval Management Arrival Operations

    Science.gov (United States)

    Baxley, Brian T.; Wilson, Sara R.; Swieringa, Kurt A.; Johnson, William C.; Roper, Roy D.; Hubbs, Clay E.; Goess, Paul A.; Shay, Richard F.

    2016-01-01

    Interval Management Alternative Clearances (IMAC) was a human-in-the-loop simulation experiment conducted to explore the Air Traffic Management (ATM) Technology Demonstration (ATD-1) Concept of Operations (ConOps), which combines advanced arrival scheduling, controller decision support tools, and aircraft avionics to enable multiple time deconflicted, efficient arrival streams into a high-density terminal airspace. Interval Management (IM) is designed to support the ATD-1 concept by having an "Ownship" (IM-capable) aircraft achieve or maintain a specific time or distance behind a "Target" (preceding) aircraft. The IM software uses IM clearance information and the Ownship data (route of flight, current location, and wind) entered by the flight crew, and the Target aircraft's Automatic Dependent Surveillance-Broadcast state data, to calculate the airspeed necessary for the IM-equipped aircraft to achieve or maintain the assigned spacing goal.

  2. Clearance Kinetics and Clearance Routes of Molecules From the Suprachoroidal Space After Microneedle Injection.

    Science.gov (United States)

    Chiang, Bryce; Wang, Ke; Ethier, C Ross; Prausnitz, Mark R

    2017-01-01

    To determine clearance kinetics and routes of clearance of molecules from the suprachoroidal space (SCS) of live New Zealand White rabbits. Suprachoroidal space collapse rate and pressure changes after microneedle injection into SCS were determined. Fluorescent fundus images were acquired to determine clearance rates of molecules ranging in size from 332 Da to 2 MDa. Microneedle injections of fluorescein were performed, and samples were taken from various sites over time to determine amount of fluorescein exiting the eye. Clearance transport was modeled theoretically and compared with experimental data. After injection, pressures in SCS and vitreous humor spiked and returned to baseline within 20 minutes; there was no difference between these two pressures. Suprachoroidal space collapse occurred within 40 minutes. One hour after fluorescein injection, 46% of fluorescein was still present in the eye, 15% had transported across sclera, 6% had been cleared by choroidal vasculature, and 4% had exited via leakage pathways. Characteristic clearance time increased in proportion with molecular radius, but total clearance of 2 MDa FITC-dextran was significantly slower (21 days) than smaller molecules. These data generally agreed with predictions from a theoretical model of molecular transport. Guided by experimental data in the context of model predictions, molecular clearance from SCS occurred in three regimes: (1) on a time scale of approximately 10 minutes, fluid and molecules exited SCS by diffusion into sclera and choroid, and by pressure-driven reflux via transscleral leakage sites; (2) in approximately 1 hour, molecules cleared from choroid by blood flow; and (3) in 1 to 10 hours, molecules cleared from sclera by diffusion and convection.

  3. Study on clearance system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports Nuclear Regulatory Agency on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In uranium processing facilities, simulation sources emitting alpha-rays is used in a validity confirmation examination of the measuring equipment. In this study, these sources were examined by measuring alpha and beta spectra to evaluate the applicability and problem of these sources. In addition, the measuring method detecting gamma-rays was examined. This method can be applied to complicated objects. As a part to develop a manual for unexpected incidents in clearance system, a quick method for measurement of Strontium 90 was examined. In addition, the measuring methods for the judgment of the influence of fallout and for NR (Non-Radioactive) confirmation were examined. (author)

  4. Integrins as Therapeutic Targets: Successes and Cancers

    Directory of Open Access Journals (Sweden)

    Sabine Raab-Westphal

    2017-08-01

    Full Text Available Integrins are transmembrane receptors that are central to the biology of many human pathologies. Classically mediating cell-extracellular matrix and cell-cell interaction, and with an emerging role as local activators of TGFβ, they influence cancer, fibrosis, thrombosis and inflammation. Their ligand binding and some regulatory sites are extracellular and sensitive to pharmacological intervention, as proven by the clinical success of seven drugs targeting them. The six drugs on the market in 2016 generated revenues of some US$3.5 billion, mainly from inhibitors of α4-series integrins. In this review we examine the current developments in integrin therapeutics, especially in cancer, and comment on the health economic implications of these developments.

  5. An Analytic Model for the Success Rate of a Robotic Actuator System in Hitting Random Targets.

    Science.gov (United States)

    Bradley, Stuart

    2015-11-20

    Autonomous robotic systems are increasingly being used in a wide range of applications such as precision agriculture, medicine, and the military. These systems have common features which often includes an action by an "actuator" interacting with a target. While simulations and measurements exist for the success rate of hitting targets by some systems, there is a dearth of analytic models which can give insight into, and guidance on optimization, of new robotic systems. The present paper develops a simple model for estimation of the success rate for hitting random targets from a moving platform. The model has two main dimensionless parameters: the ratio of actuator spacing to target diameter; and the ratio of platform distance moved (between actuator "firings") to the target diameter. It is found that regions of parameter space having specified high success are described by simple equations, providing guidance on design. The role of a "cost function" is introduced which, when minimized, provides optimization of design, operating, and risk mitigation costs.

  6. A model of metabolism and clearance of organic compounds from the respiratory tract

    International Nuclear Information System (INIS)

    Gerde, P.; Dahl, A.R.

    1994-01-01

    In cases where inhalants induce toxicity in the airway epithelium, the mechanism of absorption is an important determinant of target dose. Absorption of organic solutes in the lungs occurs mainly by two consecutive mechanisms; molecular diffusion drives the chemicals into the tissues, and blood perfusion of the tissues removes the chemicals into the systemic circulation. Solutes having lipophilicities ranging from equally soluble in lipids and water to moderately more lipid-soluble are limited by the perfusion during clearance from the lungs. The perfusion-limited solute enters the blood circulation from all regions of the lungs within minutes and is distributed to other organs via the systemic circulation. In contrast, clearance of highly lipophilic toxicants, such as benzo(a)pyrene, from the lungs is diffusion-limited. The limiting process refers to the slowest transport mechanism of either perfusion or diffusion. Because of the short distance from the surface of the alveolar region to the capillary network, diffusion-limited clearance of highly lipophilic solutes occurs within minutes. In the thicker epithelium of the conducting airways, however, clearance may take hours. The purpose of the current modeling effort was to encompass both mechanisms of clearance in a single model in order to explore the influence of toxicant lipophilicity and local metabolism on the dosimetry at the airway portal-of-entry

  7. Clearance of materials from accelerator facilities

    Directory of Open Access Journals (Sweden)

    Rokni Sayed H.

    2017-01-01

    Full Text Available A new Technical Standard that supports the clearance of materials and equipment (personal property from U.S. Department of Energy (DOE accelerator facilities has been developed. The Standard focuses on personal property that has the potential to be radiologically impacted by accelerator operations. It addresses material clearance programs and protocols for off-site releases without restriction on use. Common metals with potential volumetric activation are of main interest with technical bases provided in Appendices of the Standard. The clearance protocols in the Standard include three elements: 1 clearance criteria, 2 process knowledge, and 3 measurement methods. This paper presents the technical aspects of the new Standard, discusses operational experience gained in clearance of materials and equipment from several accelerator facilities at SLAC and examples as to how this Standard can be applied to benefit the entirety of the DOE Accelerator Complex.

  8. Distribution and clearance of PEG-single-walled carbon nanotube cancer drug delivery vehicles in mice.

    Science.gov (United States)

    Bhirde, Ashwin A; Patel, Sachin; Sousa, Alioscka A; Patel, Vyomesh; Molinolo, Alfredo A; Ji, Youngmi; Leapman, Richard D; Gutkind, J Silvio; Rusling, James F

    2010-12-01

    To study the distribution and clearance of polyethylene glycol (PEG)-ylated single-walled carbon nanotube (SWCNTs) as drug delivery vehicles for the anticancer drug cisplatin in mice. PEG layers were attached to SWCNTs and dispersed in aqueous media and characterized using dynamic light scattering, scanning transmission electron microscopy and Raman spectroscopy. Cytotoxicity was assessed in vitro using Annexin-V assay, and the distribution and clearance pathways in mice were studied by histological staining and Raman spectroscopy. Efficacy of PEG-SWCNT-cisplatin for tumor growth inhibition was studied in mice. PEG-SWCNTs were efficiently dispersed in aqueous media compared with controls, and did not induce apoptosis in vitro. Hematoxylin and eosin staining, and Raman bands for SWCNTs in tissues from several vital organs from mice injected intravenously with nanotube bioconjugates revealed that control SWCNTs were lodged in lung tissue as large aggregates compared with the PEG-SWCNTs, which showed little or no accumulation. Characteristic SWCNT Raman bands in feces revealed the presence of bilary or renal excretion routes. Attachment of cisplatin on bioconjugates was visualized with Z-contrast scanning transmission electron microscopy. PEG-SWCNT-cisplatin with the attached targeting ligand EGF successfully inhibited growth of head and neck tumor xenografts in mice. PEG-SWCNTs, as opposed to control SWCNTs, form more highly dispersed delivery vehicles that, when loaded with both cisplatin and EGF, inhibit growth of squamous cell tumors.

  9. Macrophage Clearance of Apoptotic Cells: A Critical Assessment

    Directory of Open Access Journals (Sweden)

    Siamon Gordon

    2018-01-01

    Full Text Available As the body continues to grow and age, it becomes essential to maintain a balance between living and dying cells. Macrophages and dendritic cells play a central role in discriminating among viable, apoptotic, and necrotic cells, as selective and efficient phagocytes, without inducing inappropriate inflammation or immune responses. A great deal has been learnt concerning clearance receptors for modified and non-self-ligands on potential targets, mediating their eventual uptake, disposal, and replacement. In this essay, we assess current understanding of the phagocytic recognition of apoptotic cells within their tissue environment; we conclude that efferocytosis constitutes a more complex process than simply removal of corpses, with regulatory interactions between the target and effector cells, which determine the outcome of this homeostatic process.

  10. Rational customs clearance technology choice

    OpenAIRE

    Shramenko, N.; Andriets, V.

    2008-01-01

    Issues concerning cargo delivery efficiencyincrease by choice of rational customs clearance technology have been considered. Three possible variants of customs clearance andmethods which allow to define the most rational version of cargo delivery in international road communication based on main efficiency criteria for definite distance have been presented.

  11. Importance of Bacterial Replication and Alveolar Macrophage-Independent Clearance Mechanisms during Early Lung Infection with Streptococcus pneumoniae

    Science.gov (United States)

    Camberlein, Emilie; Cohen, Jonathan M.; José, Ricardo; Hyams, Catherine J.; Callard, Robin; Chimalapati, Suneeta; Yuste, Jose; Edwards, Lindsey A.; Marshall, Helina; van Rooijen, Nico; Noursadeghi, Mahdad

    2015-01-01

    Although the importance of alveolar macrophages for host immunity during early Streptococcus pneumoniae lung infection is well established, the contribution and relative importance of other innate immunity mechanisms and of bacterial factors are less clear. We have used a murine model of S. pneumoniae early lung infection with wild-type, unencapsulated, and para-amino benzoic acid auxotroph mutant TIGR4 strains to assess the effects of inoculum size, bacterial replication, capsule, and alveolar macrophage-dependent and -independent clearance mechanisms on bacterial persistence within the lungs. Alveolar macrophage-dependent and -independent (calculated indirectly) clearance half-lives and bacterial replication doubling times were estimated using a mathematical model. In this model, after infection with a high-dose inoculum of encapsulated S. pneumoniae, alveolar macrophage-independent clearance mechanisms were dominant, with a clearance half-life of 24 min compared to 135 min for alveolar macrophage-dependent clearance. In addition, after a high-dose inoculum, successful lung infection required rapid bacterial replication, with an estimated S. pneumoniae doubling time of 16 min. The capsule had wide effects on early lung clearance mechanisms, with reduced half-lives of 14 min for alveolar macrophage-independent and 31 min for alveolar macrophage-dependent clearance of unencapsulated bacteria. In contrast, with a lower-dose inoculum, the bacterial doubling time increased to 56 min and the S. pneumoniae alveolar macrophage-dependent clearance half-life improved to 42 min and was largely unaffected by the capsule. These data demonstrate the large effects of bacterial factors (inoculum size, the capsule, and rapid replication) and alveolar macrophage-independent clearance mechanisms during early lung infection with S. pneumoniae. PMID:25583525

  12. 7 CFR 1927.55 - Title clearance services.

    Science.gov (United States)

    2010-01-01

    ... REGULATIONS TITLE CLEARANCE AND LOAN CLOSING Real Estate Title Clearance and Loan Closing § 1927.55 Title clearance services. (a) Responsibilities of closing agents. Services to be provided to the agency and the borrower by a closing agent in connection with the transaction vary depending on whether a title insurance...

  13. Relationship between silicon concentration and creatinine clearance

    International Nuclear Information System (INIS)

    Miura, Y.; Nakai, K.; Itoh, C.; Horikiri, J.; Sera, K.; Sato, M.

    1998-01-01

    Silicon levels in dialysis patients are markedly increasing. Using PIXE we determined the relationship between silicon concentration and creatinine clearance in 30 samples. Urine silicon concentration were significantly correlated to creatinine clearance (p<0.001). And also serum silicon concentration were significantly correlated to creatinine clearance (p<0.0001). (author)

  14. Verification of surface contamination density standard using clearance automatic laser inspection system for objects from a nuclear power plant

    International Nuclear Information System (INIS)

    Sasaki, Michiya; Ogino, Haruyuki; Ichiji, Takeshi; Hattori, Takatoshi

    2008-01-01

    In the clearance level inspection in Japan, it is necessary to indicate that the activity level of the target object must be less than not only the clearance levels, but also the surface contamination density standards. The classification measurements for these two standards have been performed separately, and the GM survey meters based on beta-ray measurement have mainly been used for surface contamination density measurement so far. Recently the Clearance Automatic Laser Inspection System, named CLALIS, has been developed to estimate the low-level activity concentration. This system consists of 3-dimensional laser scanner for shape measurement and eight large NE102A plastic scintillation detectors for gamma-ray measurement, and it has been clarified that the CLALIS has adequate detection ability for clearance measurement of both metal scraps and concrete debris. In this study, we compared the surface contamination densities for a number of actual contaminated and non-contaminated objects generated inside from the radiation controlled area at the Kashiwazaki-Kariwa nuclear power station by using the CLALIS and the GM survey meter. As a result, since CLALIS could detect the surface contamination as well as the GM survey meter for all measurement targets, it was revealed that CLALIS can rationally achieve clearance level inspection in a single radiation measurement. The practicality of CLALIS in view of the detection limit and processing time was discussed by comparison with the usual radiation monitors for surface contamination measurement. (author)

  15. Compressor airfoil tip clearance optimization system

    Science.gov (United States)

    Little, David A.; Pu, Zhengxiang

    2015-08-18

    A compressor airfoil tip clearance optimization system for reducing a gap between a tip of a compressor airfoil and a radially adjacent component of a turbine engine is disclosed. The turbine engine may include ID and OD flowpath boundaries configured to minimize compressor airfoil tip clearances during turbine engine operation in cooperation with one or more clearance reduction systems that are configured to move the rotor assembly axially to reduce tip clearance. The configurations of the ID and OD flowpath boundaries enhance the effectiveness of the axial movement of the rotor assembly, which includes movement of the ID flowpath boundary. During operation of the turbine engine, the rotor assembly may be moved axially to increase the efficiency of the turbine engine.

  16. Noninvasive determination of individual renal clearance

    International Nuclear Information System (INIS)

    Chanard, J.; Brunois, J.P.; Ruiz, J.C.; Assailly, J.

    1980-01-01

    A noninvasive method for measurement of individual renal clearance is presented, based on analysis of the early rise of the kidneys' time-activity curves after injection of an appropriate tracer ( 131 I-ortho-iodohippurate for tubular function or 111 In DTPA for glomerular clearance). The analysis is based on the assumption that an insignificant amount of tracer leaves the kidney during the first few moments following injection. Therefore, the kidney activity during this period is directly proportional to the integral of the blood (heart) activity. After blood background subtraction, the linear correlation between the early part of the renogram and the corresponding blood integral activity curve allows calculation of an angular coefficient. The ratio of these coefficients calculated for each kidney is proportional to the ratio of the individual clearances. The latter are calculated from the total clearance simultaneously measured using a simplified method without urine collection. In control subjects with normal renal function individual renal clearances were not significantly different. In uninephrectomized patients a precision of 5% in calculating individual clearance was estimated from data recorded at the level of the remaining kidney. In patients with functional asymmetry, results were compared with 197 HgCl 2 quantitative renal fixation. A linear correlation was found (r = 0.95). The method we propose seems valuable for clinical investigation and allows sequential measurements. (orig.)

  17. Dynamic clearance measure to evaluate locomotor and perceptuo-motor strategies used for obstacle circumvention in a virtual environment.

    Science.gov (United States)

    Darekar, Anuja; Lamontagne, Anouk; Fung, Joyce

    2015-04-01

    Circumvention around an obstacle entails a dynamic interaction with the obstacle to maintain a safe clearance. We used a novel mathematical interpolation method based on the modified Shepard's method of Inverse Distance Weighting to compute dynamic clearance that reflected this interaction as well as minimal clearance. This proof-of-principle study included seven young healthy, four post-stroke and four healthy age-matched individuals. A virtual environment designed to assess obstacle circumvention was used to administer a locomotor (walking) and a perceptuo-motor (navigation with a joystick) task. In both tasks, participants were asked to navigate towards a target while avoiding collision with a moving obstacle that approached from either head-on, or 30° left or right. Among young individuals, dynamic clearance did not differ significantly between obstacle approach directions in both tasks. Post-stroke individuals maintained larger and smaller dynamic clearance during the locomotor and the perceptuo-motor task respectively as compared to age-matched controls. Dynamic clearance was larger than minimal distance from the obstacle irrespective of the group, task and obstacle approach direction. Also, in contrast to minimal distance, dynamic clearance can respond differently to different avoidance behaviors. Such a measure can be beneficial in contrasting obstacle avoidance behaviors in different populations with mobility problems. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Using cholecystokinin to facilitate endoscopic clearance of large common bile duct stones

    Science.gov (United States)

    Tao, Tao; Zhang, Qi-Jie; Zhang, Ming; Zhu, Xiao; Sun, Shu-Xia; Li, Yan-Qing

    2014-01-01

    AIM: To evaluate the effect of cholecystokinin (CCK) during extracorporeal shockwave lithotripsy (ESWL) in the clearance of common bile duct (CBD) stones in endoscopic retrograde cholangiopancreatography (ERCP). METHODS: Between January 2007 and September 2012, patients with large CBD stones who were treated with ESWL and ERCP were identified retrospectively. Patients were randomized in equal numbers to cholecystokinin (CCK) and no CCK groups. For each CCK case, a dose (3 ng/kg per min for 10 min) of sulfated octapeptide of CCK-8 was administered intravenously near the beginning of ESWL. ERCP was performed 4 h after a session of ESWL. The clearance rate of the CBD was assessed between the two groups. RESULTS: A total of 148 consecutive cases (CCK group: 74, no CCK group: 74) were tallied. Overall there were 234 ESWLs and 228 ERCPs in the 148 cases. The use of CCK showed a significantly higher rate of successful stone removal in the first ESWL/ERCP procedure (71.6% vs 55.4%, P = 0.035), but resulted in similar outcomes in the second (42.8% vs 39.4%) and third (41.7% vs 40.0%) sessions, as well as total stone clearance (90.5% vs 83.8%). The use of mechanical lithotripsy was reduced in the CCK group (6.8% vs 17.6%, P = 0.023), and extremely large stone (≥ 30 mm) removal was higher in the CCK group (72.7% vs 41.7%, P = 0.038). CONCLUSION: CCK during ESWL can aid with the clearance of CBD stones in the first ESWL/ERCP session. Mechanical lithotripsy usage was reduced and the extremely large stone (≥ 30 mm) clearance rate can be raised. PMID:25110439

  19. Delayed nerve stimulation promotes axon-protective neurofilament phosphorylation, accelerates immune cell clearance and enhances remyelination in vivo in focally demyelinated nerves.

    Directory of Open Access Journals (Sweden)

    Nikki A McLean

    Full Text Available Rapid and efficient axon remyelination aids in restoring strong electrochemical communication with end organs and in preventing axonal degeneration often observed in demyelinating neuropathies. The signals from axons that can trigger more effective remyelination in vivo are still being elucidated. Here we report the remarkable effect of delayed brief electrical nerve stimulation (ES; 1 hour @ 20 Hz 5 days post-demyelination on ensuing reparative events in a focally demyelinated adult rat peripheral nerve. ES impacted many parameters underlying successful remyelination. It effected increased neurofilament expression and phosphorylation, both implicated in axon protection. ES increased expression of myelin basic protein (MBP and promoted node of Ranvier re-organization, both of which coincided with the early reappearance of remyelinated axons, effects not observed at the same time points in non-stimulated demyelinated nerves. The improved ES-associated remyelination was accompanied by enhanced clearance of ED-1 positive macrophages and attenuation of glial fibrillary acidic protein expression in accompanying Schwann cells, suggesting a more rapid clearance of myelin debris and return of Schwann cells to a nonreactive myelinating state. These benefits of ES correlated with increased levels of brain derived neurotrophic factor (BDNF in the acute demyelination zone, a key molecule in the initiation of the myelination program. In conclusion, the tremendous impact of delayed brief nerve stimulation on enhancement of the innate capacity of a focally demyelinated nerve to successfully remyelinate identifies manipulation of this axis as a novel therapeutic target for demyelinating pathologies.

  20. Delayed nerve stimulation promotes axon-protective neurofilament phosphorylation, accelerates immune cell clearance and enhances remyelination in vivo in focally demyelinated nerves.

    Science.gov (United States)

    McLean, Nikki A; Popescu, Bogdan F; Gordon, Tessa; Zochodne, Douglas W; Verge, Valerie M K

    2014-01-01

    Rapid and efficient axon remyelination aids in restoring strong electrochemical communication with end organs and in preventing axonal degeneration often observed in demyelinating neuropathies. The signals from axons that can trigger more effective remyelination in vivo are still being elucidated. Here we report the remarkable effect of delayed brief electrical nerve stimulation (ES; 1 hour @ 20 Hz 5 days post-demyelination) on ensuing reparative events in a focally demyelinated adult rat peripheral nerve. ES impacted many parameters underlying successful remyelination. It effected increased neurofilament expression and phosphorylation, both implicated in axon protection. ES increased expression of myelin basic protein (MBP) and promoted node of Ranvier re-organization, both of which coincided with the early reappearance of remyelinated axons, effects not observed at the same time points in non-stimulated demyelinated nerves. The improved ES-associated remyelination was accompanied by enhanced clearance of ED-1 positive macrophages and attenuation of glial fibrillary acidic protein expression in accompanying Schwann cells, suggesting a more rapid clearance of myelin debris and return of Schwann cells to a nonreactive myelinating state. These benefits of ES correlated with increased levels of brain derived neurotrophic factor (BDNF) in the acute demyelination zone, a key molecule in the initiation of the myelination program. In conclusion, the tremendous impact of delayed brief nerve stimulation on enhancement of the innate capacity of a focally demyelinated nerve to successfully remyelinate identifies manipulation of this axis as a novel therapeutic target for demyelinating pathologies.

  1. A model of clearance rate regulation in mussels

    Science.gov (United States)

    Fréchette, Marcel

    2012-10-01

    Clearance rate regulation has been modelled as an instantaneous response to food availability, independent of the internal state of the animals. This view is incompatible with latent effects during ontogeny and phenotypic flexibility in clearance rate. Internal-state regulation of clearance rate is required to account for these patterns. Here I develop a model of internal-state based regulation of clearance rate. External factors such as suspended sediments are included in the model. To assess the relative merits of instantaneous regulation and internal-state regulation, I modelled blue mussel clearance rate and growth using a DEB model. In the usual standard feeding module, feeding is governed by a Holling's Type II response to food concentration. In the internal-state feeding module, gill ciliary activity and thus clearance rate are driven by internal reserve level. Factors such as suspended sediments were not included in the simulations. The two feeding modules were compared on the basis of their ability to capture the impact of latent effects, of environmental heterogeneity in food abundance and of physiological flexibility on clearance rate and individual growth. The Holling feeding module was unable to capture the effect of any of these sources of variability. In contrast, the internal-state feeding module did so without any modification or ad hoc calibration. Latent effects, however, appeared transient. With simple annual variability in temperature and food concentration, the relationship between clearance rate and food availability predicted by the internal-state feeding module was quite similar to that observed in Norwegian fjords. I conclude that in contrast with the usual Holling feeding module, internal-state regulation of clearance rate is consistent with well-documented growth and clearance rate patterns.

  2. Arctigenin effectively ameliorates memory impairment in Alzheimer's disease model mice targeting both β-amyloid production and clearance.

    Science.gov (United States)

    Zhu, Zhiyuan; Yan, Jianming; Jiang, Wei; Yao, Xin-gang; Chen, Jing; Chen, Lili; Li, Chenjing; Hu, Lihong; Jiang, Hualiang; Shen, Xu

    2013-08-07

    Alzheimer's disease (AD) chiefly characterizes a progressively neurodegenerative disorder of the brain, and eventually leads to irreversible loss of intellectual abilities. The β-amyloid (Aβ)-induced neurodegeneration is believed to be the main pathological mechanism of AD, and Aβ production inhibition or its clearance promotion is one of the promising therapeutic strategies for anti-AD research. Here, we report that the natural product arctigenin from Arctium lappa (L.) can both inhibit Aβ production by suppressing β-site amyloid precursor protein cleavage enzyme 1 expression and promote Aβ clearance by enhancing autophagy through AKT/mTOR signaling inhibition and AMPK/Raptor pathway activation as investigated in cells and APP/PS1 transgenic AD model mice. Moreover, the results showing that treatment of arctigenin in mice highly decreased Aβ formation and senile plaques and efficiently ameliorated AD mouse memory impairment strongly highlight the potential of arctigenin in anti-AD drug discovery.

  3. Beams configuration design in target area with successive quadratic programming method

    International Nuclear Information System (INIS)

    Shi Zhiquan; Tan Jichun; Wei Xiaofeng; Man Jongzai; Zhang Xiaomin; Yuan Jing; Yuan Xiaodong

    1998-01-01

    The author describes the application of successive quadratic programming method (SQP) to design laser beam configuration in target area. Based on the requirement of ICF experiment physics, a math model of indirect-driver beam geometry is given. A 3D wire-frame is plotted, in which support lines represent 60 laser entireties and 240 turning points of support lines' segments stand for the spatial positions of reflectors

  4. Predicting Human Clearance of OATP substrates using Cynomolgus monkey: In vitro-in vivo scaling of hepatic uptake clearance.

    Science.gov (United States)

    de Bruyn, Tom; Ufuk, Ayse; Cantrill, Carina; Kosa, Rachel E; Bi, Yi-An; Niosi, Mark; Modi, Sweta; Rodrigues, A David; Tremaine, Larry M; Varma, Manthena Vs; Galetin, Aleksandra; Houston, J Brian

    2018-05-02

    This work explores the utility of the cynomolgus monkey as a preclinical model to predict hepatic uptake clearance mediated by organic anion transporting polypeptide (OATP) transporters. Nine OATP substrates (rosuvastatin, pravastatin, repaglinide, fexofenadine, cerivastatin, telmisartan, pitavastatin, bosentan and valsartan) were investigated in plated cynomolgus monkey and human hepatocytes. Total uptake clearance and passive diffusion were measured in vitro from initial rates in the absence and presence of the OATP inhibitor rifamycin SV, respectively. Total uptake clearance values in plated hepatocytes ranged over three orders of magnitude in both species with a similar rank order and good agreement in the relative contribution of active transport to total uptake between cynomolgus monkey and human. In vivo hepatic clearance for these nine drugs was determined in cynomolgus monkey after intravenous dosing. Hepatic clearances showed a similar range to human parameters and good predictions from respective hepatocyte parameters (with 2.7 and 3.8-fold bias on average, respectively). The use of cross species empirical scaling factors (based on either dataset average or individual drug scaling factor from cynomolgus monkey data) improved prediction (less bias, better concordance) of human hepatic clearance from human hepatocyte data alone. In vitro intracellular binding in hepatocytes also correlated well between species. It is concluded that the minimal species differences observed for the current dataset between cynomolgus monkey and human hepatocyte uptake, both in vitro and in vivo, support future use of this preclinical model to delineate drug hepatic uptake and enable prediction of human in vivo intrinsic hepatic clearance. The American Society for Pharmacology and Experimental Therapeutics.

  5. 48 CFR 801.602-76 - Business clearance review.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Business clearance review... GENERAL DEPARTMENT OF VETERANS AFFAIRS ACQUISITION REGULATION SYSTEM Career Development, Contracting Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a...

  6. Targeting protein biotinylation enhances tuberculosis chemotherapy.

    Science.gov (United States)

    Tiwari, Divya; Park, Sae Woong; Essawy, Maram M; Dawadi, Surendra; Mason, Alan; Nandakumar, Madhumitha; Zimmerman, Matthew; Mina, Marizel; Ho, Hsin Pin; Engelhart, Curtis A; Ioerger, Thomas; Sacchettini, James C; Rhee, Kyu; Ehrt, Sabine; Aldrich, Courtney C; Dartois, Véronique; Schnappinger, Dirk

    2018-04-25

    Successful drug treatment for tuberculosis (TB) depends on the unique contributions of its component drugs. Drug resistance poses a threat to the efficacy of individual drugs and the regimens to which they contribute. Biologically and chemically validated targets capable of replacing individual components of current TB chemotherapy are a major unmet need in TB drug development. We demonstrate that chemical inhibition of the bacterial biotin protein ligase (BPL) with the inhibitor Bio-AMS (5'-[ N -(d-biotinoyl)sulfamoyl]amino-5'-deoxyadenosine) killed Mycobacterium tuberculosis ( Mtb ), the bacterial pathogen causing TB. We also show that genetic silencing of BPL eliminated the pathogen efficiently from mice during acute and chronic infection with Mtb Partial chemical inactivation of BPL increased the potency of two first-line drugs, rifampicin and ethambutol, and genetic interference with protein biotinylation accelerated clearance of Mtb from mouse lungs and spleens by rifampicin. These studies validate BPL as a potential drug target that could serve as an alternate frontline target in the development of new drugs against Mtb . Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  7. Estimation of 131I hippuran clearance during pregnancy

    International Nuclear Information System (INIS)

    Voigt, R.; Stoll, W.; Zenner, I.; Arndt, J.; Friedrich-Schiller-Univ., Jena

    1979-01-01

    Changes in 131 I hippuran clearance were estimated by a non-catheter method, as well as total clearance and clearance of each kidney, in 43 women at various stages of pregnancy and in 13 non-pregnant women who were not using hormonal contraceptives. The results are demonstrated in graph form. The methods used are described in detail. The procedure for determining clearance in separate kidneys is indicated. It was found that clearance values increased up to the 35th and 26th weeks of pregnancy. The difference between the sides that were found corresponds with the previously known difference in the function of the right and left kidneys and ureters. (orig.) [de

  8. Hepatic transcriptome analysis of hepatitis C virus infection in chimpanzees defines unique gene expression patterns associated with viral clearance.

    Directory of Open Access Journals (Sweden)

    Santosh Nanda

    Full Text Available Hepatitis C virus infection leads to a high rate of chronicity. Mechanisms of viral clearance and persistence are still poorly understood. In this study, hepatic gene expression analysis was performed to identify any molecular signature associated with the outcome of hepatitis C virus (HCV infection in chimpanzees. Acutely HCV-infected chimpanzees with self-limited infection or progression to chronicity were studied. Interferon stimulated genes were induced irrespective of the outcome of infection. Early induction of a set of genes associated with cell proliferation and immune activation was associated with subsequent viral clearance. Specifically, two of the genes: interleukin binding factor 3 (ILF3 and cytotoxic granule-associated RNA binding protein (TIA1, associated with robust T-cell response, were highly induced early in chimpanzees with self-limited infection. Up-regulation of genes associated with CD8+ T cell response was evident only during the clearance phase of the acute self-limited infection. The induction of these genes may represent an initial response of cellular injury and proliferation that successfully translates to a "danger signal" leading to induction of adaptive immunity to control viral infection. This primary difference in hepatic gene expression between self-limited and chronic infections supports the concept that successful activation of HCV-specific T-cell response is critical in clearance of acute HCV infection.

  9. Frequency and causes of discrepancy between Kt/V and creatinine clearance.

    Science.gov (United States)

    Satko, S G; Burkart, J M; Bleyer, A J; Jordan, J R; Manning, T

    1999-01-01

    This study examines the frequency of discrepancy between Kt/V urea and creatinine clearance (Ccr) measurements in patients on peritoneal dialysis (PD) and the reasons for this discrepancy. Nonrandomized, retrospective data analysis. Single PD unit of a university teaching hospital. All adult patients receiving PD at our center from January 1995 to December 1996. Actual (a) and desired (d) body weight (BW) were used to calculate urea volume of distribution (V) and body surface area (BSA). Patients were divided into four groups based upon their total small solute clearances (Kt/V and Ccr, normalized by actual weight) and three additional groups based upon actual/desired (a/d) body weight ratio. An additional analysis was performed for the subset of anuric patients. Data collected for all patients included the following: total Kt, total Ccr, 4-hour dialysate/ plasma (D/P) creatinine, serum albumin concentration, duration of PD, actual body weight, age, and height. Twenty-three percent of the clearance measurements in our study were discrepant, defined as having values for either Kt/V or Ccr (but not both) above the accepted targets of Kt/V > or = 2.0/wk and Ccr > or = 60 L/wk/ 1.73 m2. Patients with both values above target are more likely to have higher residual renal function. Patients who are significantly less than BWd and patients on PD for a longer time are more likely to have adequate Kt/V but not Ccr. Furthermore, patients who are less than 90% or greater than 110% of BWd have markedly different values for Kt/V and Ccr when BWa versus BWd values are used. Kt/V and Ccr values are frequently discrepant; a number of factors affect these two measurements to varying degrees, including weight, degree of residual renal function, and duration of PD.

  10. Establishing exemption and clearance criteria by the regulatory authority

    International Nuclear Information System (INIS)

    Salih, A.E.A.

    2012-04-01

    This Project work discusses the relationship between the concepts of exemption and clearance, and their practical use in the overall scheme of regulatory control of practices. It also discusses how exemptions and clearance is established and the scope of its applications for regulatory control. The concept of general clearance levels for any type of material and any possible pathway of disposal is also introduced in this work. Guidance of the Group of Experts establishing scenarios for general clearance, parameter values, and a nuclide-specific list of calculated clearance levels is also presented. Regulatory authorities are required to develop guidance on exemption and clearance levels to assist licensees and registrants to know which practices and sources within practices are exempted from regulatory control and those to be cleared from further controls. Exemption and clearance levels are tools for assisting the Regulatory Authority to optimize the use of resources. (author)

  11. 14 CFR 1260.63 - Customs clearance and visas.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  12. Rotating coherent flow structures as a source for narrowband tip clearance noise from axial fans

    Science.gov (United States)

    Zhu, Tao; Lallier-Daniels, Dominic; Sanjosé, Marlène; Moreau, Stéphane; Carolus, Thomas

    2018-03-01

    Noise from axial fans typically increases significantly as the tip clearance is increased. In addition to the broadband tip clearance noise at the design flow rate, narrowband humps also associated with the tip flow are observed in the far-field acoustic spectra at lower flow rate. In this study, both experimental and numerical methods are used to shed more light on the noise generation mechanism of this narrowband tip clearance noise and provide a unified description of this source. Unsteady aeroacoustic predictions with the Lattice-Boltzmann Method (LBM) are successfully compared with experiment. Such a validation allows using LBM data to conduct a detailed modal analysis of the pressure field for detecting rotating coherent flow structures which might be considered as noise sources. As previously found in ring fans the narrowband humps in the far-field noise spectra are found to be related to the tip clearance noise that is generated by an interaction of coherent flow structures present in the tip region with the leading edge of the impeller blades. The visualization of the coherent structures shows that they are indeed part of the unsteady tip clearance vortex structures. They are hidden in a complex, spatially and temporally inhomogeneous flow field, but can be recovered by means of appropriate filtering techniques. Their pressure trace corresponds to the so-called rotational instability identified in previous turbomachinery studies, which brings a unified picture of this tip-noise phenomenon for the first time.

  13. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...

  14. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....

  15. Clearance Laboratory - Capability and measurement sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-08-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  16. Clearance Laboratory - Capability and measurement sensitivity

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-09-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  17. Hyperglycemia Impairs Neutrophil-Mediated Bacterial Clearance in Mice Infected with the Lyme Disease Pathogen.

    Directory of Open Access Journals (Sweden)

    Ashkan Javid

    Full Text Available Insulin-insufficient type 1 diabetes is associated with attenuated bactericidal function of neutrophils, which are key mediators of innate immune responses to microbes as well as pathological inflammatory processes. Neutrophils are central to immune responses to the Lyme pathogen Borrelia burgdorferi. The effect of hyperglycemia on host susceptibility to and outcomes of B. burgdorferi infection has not been examined. The present study investigated the impact of sustained obesity-independent hyperglycemia in mice on bacterial clearance, inflammatory pathology and neutrophil responses to B. burgdorferi. Hyperglycemia was associated with reduced arthritis incidence but more widespread tissue colonization and reduced clearance of bacterial DNA in multiple tissues including brain, heart, liver, lung and knee joint. B. burgdorferi uptake and killing were impaired in neutrophils isolated from hyperglycemic mice. Thus, attenuated neutrophil function in insulin-insufficient hyperglycemia was associated with reduced B. burgdorferi clearance in target organs. These data suggest that investigating the effects of comorbid conditions such as diabetes on outcomes of B. burgdorferi infections in humans may be warranted.

  18. Lithium clearance in chronic nephropathy

    DEFF Research Database (Denmark)

    Kamper, A L; Holstein-Rathlou, N H; Leyssac, P P

    1989-01-01

    1. Lithium clearance measurements were made in 72 patients with chronic nephropathy of different aetiology and moderate to severely reduced renal function. 2. Lithium clearance was strictly correlated with glomerular filtration rate, and there was no suggestion of distal tubular reabsorption...... of lithium or influence of osmotic diuresis. 3. Fractional reabsorption of lithium was reduced in most patients with glomerular filtration rates below 25 ml/min. 4. Calculated fractional distal reabsorption of sodium was reduced in most patients with glomerular filtration rates below 50 ml/min. 5. Lithium...... that lithium clearance may be a measure of the delivery of sodium and water from the renal proximal tubule. With this assumption it was found that adjustment of the sodium excretion in chronic nephropathy initially takes place in the distal parts of the nephron (loop of Henle, distal tubule and collecting duct...

  19. 19 CFR 122.26 - Entry and clearance.

    Science.gov (United States)

    2010-04-01

    ... AIR COMMERCE REGULATIONS Private Aircraft § 122.26 Entry and clearance. Private aircraft, as defined... information as set forth in § 122.22(c), and grants electronic clearance via electronic mail or telephone...

  20. Clearance systems in the brain—implications for Alzheimer disease

    Science.gov (United States)

    Tarasoff-Conway, Jenna M.; Carare, Roxana O.; Osorio, Ricardo S.; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V.; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J.

    2015-01-01

    Accumulation of toxic protein aggregates—amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles—is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood–brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ. PMID:26195256

  1. Clearance systems in the brain-implications for Alzheimer disease.

    Science.gov (United States)

    Tarasoff-Conway, Jenna M; Carare, Roxana O; Osorio, Ricardo S; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J

    2015-08-01

    Accumulation of toxic protein aggregates-amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles-is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood-brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ.

  2. Secretin enhances [14C]erythritol clearance in unanesthetized dogs

    International Nuclear Information System (INIS)

    Lewis, M.H.; Baker, A.L.; Dhorajiwala, J.; Moossa, A.R.

    1982-01-01

    To determine the effect of secretin infusion on clearance of inert markers into bile, unanesthetized dogs fitted with Thomas cannulas received continuous infusions of [ 14 C]erythritol and [ 3 H]inulin throughout study. Taurocholic acid administered sequentially at 9.0, 20.0, and 40.0 mumol/min enhanced [ 14 C]erythritol clearance, and GIH secretin (3 units/min) administered along with TCA (40.0 mumol/min) increased [ 14 C]erythritol clearance from 4.9 +/- 1.2 ml/10 min to 6.8 +/- 1.3 ml/10 min (P less than 0.001), but simultaneously measured [ 3 H]inulin clearance was unaltered. Secretin alone also increased [ 14 C]erythritol clearance but did not alter [ 3 H]inulin clearance. The increase in [ 14 C]erythritol clearance per unit increase in bile flow was less during secretin infusion than TCA. Thus, secretin increases [ 14 C]erythritol transport through restricted channels, probably distal to the canaliculi. [ 14 C]Erythritol may not be an accurate marker for canalicular bile flow in dogs during secretin infusion

  3. Targeting Strategies for the Combination Treatment of Cancer Using Drug Delivery Systems

    Science.gov (United States)

    Kydd, Janel; Jadia, Rahul; Velpurisiva, Praveena; Gad, Aniket; Paliwal, Shailee; Rai, Prakash

    2017-01-01

    Cancer cells have characteristics of acquired and intrinsic resistances to chemotherapy treatment—due to the hostile tumor microenvironment—that create a significant challenge for effective therapeutic regimens. Multidrug resistance, collateral toxicity to normal cells, and detrimental systemic side effects present significant obstacles, necessitating alternative and safer treatment strategies. Traditional administration of chemotherapeutics has demonstrated minimal success due to the non-specificity of action, uptake and rapid clearance by the immune system, and subsequent metabolic alteration and poor tumor penetration. Nanomedicine can provide a more effective approach to targeting cancer by focusing on the vascular, tissue, and cellular characteristics that are unique to solid tumors. Targeted methods of treatment using nanoparticles can decrease the likelihood of resistant clonal populations of cancerous cells. Dual encapsulation of chemotherapeutic drug allows simultaneous targeting of more than one characteristic of the tumor. Several first-generation, non-targeted nanomedicines have received clinical approval starting with Doxil® in 1995. However, more than two decades later, second-generation or targeted nanomedicines have yet to be approved for treatment despite promising results in pre-clinical studies. This review highlights recent studies using targeted nanoparticles for cancer treatment focusing on approaches that target either the tumor vasculature (referred to as ‘vascular targeting’), the tumor microenvironment (‘tissue targeting’) or the individual cancer cells (‘cellular targeting’). Recent studies combining these different targeting methods are also discussed in this review. Finally, this review summarizes some of the reasons for the lack of clinical success in the field of targeted nanomedicines. PMID:29036899

  4. Targeting Strategies for the Combination Treatment of Cancer Using Drug Delivery Systems

    Directory of Open Access Journals (Sweden)

    Janel Kydd

    2017-10-01

    Full Text Available Cancer cells have characteristics of acquired and intrinsic resistances to chemotherapy treatment—due to the hostile tumor microenvironment—that create a significant challenge for effective therapeutic regimens. Multidrug resistance, collateral toxicity to normal cells, and detrimental systemic side effects present significant obstacles, necessitating alternative and safer treatment strategies. Traditional administration of chemotherapeutics has demonstrated minimal success due to the non-specificity of action, uptake and rapid clearance by the immune system, and subsequent metabolic alteration and poor tumor penetration. Nanomedicine can provide a more effective approach to targeting cancer by focusing on the vascular, tissue, and cellular characteristics that are unique to solid tumors. Targeted methods of treatment using nanoparticles can decrease the likelihood of resistant clonal populations of cancerous cells. Dual encapsulation of chemotherapeutic drug allows simultaneous targeting of more than one characteristic of the tumor. Several first-generation, non-targeted nanomedicines have received clinical approval starting with Doxil® in 1995. However, more than two decades later, second-generation or targeted nanomedicines have yet to be approved for treatment despite promising results in pre-clinical studies. This review highlights recent studies using targeted nanoparticles for cancer treatment focusing on approaches that target either the tumor vasculature (referred to as ‘vascular targeting’, the tumor microenvironment (‘tissue targeting’ or the individual cancer cells (‘cellular targeting’. Recent studies combining these different targeting methods are also discussed in this review. Finally, this review summarizes some of the reasons for the lack of clinical success in the field of targeted nanomedicines.

  5. Comparison of renal clearance of 99mTc-DTPA and inulin 131I-hippurate and PAH as well as creatinine clearance in Wistar-rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Averages and standard deviations of 99m Tc-DTPA and 131 I-hippurate slope clearance were consecutively determined for 56 male Wistar rats, with a body-weight of 271 ± 69 g in a single investigation. Clearance of 99m Tc-DTPA was 17.4 ± 3.4, that of 131 I-hippurate was 34.3 ± 7.2 μl · s -1 per 100 g body weight. For 17 rats inulin and PAH clearances were determined after 3 days with the steady-state method with continuous infusion and 3-4 periods of urine collection. During the same periods endogeneous creatinine clearance was determined. 99m Tc-DTPA slope clearance correlated well with inulin clearance, also the hippurate with the PAH clearance. The high values of the filtration fraction, calculated from radioisotope and chemical methods, and the low PAH extraction of 42% lead to the conclusion, that PAH and hippurate are incompletely eliminated by the rat kidney from plasma and therefore are inadequate for determining renal blood flow in rats. Creatinine clearance was 4.7 ± 1.38 μl · s -1 per 100 g body weight, much lower than that of inulin and 99m Tc-DTPA. Therefore is assumed, that tubular reabsorption of creatinine occurs and creatinine clearance cannot serve for the evaluation of GFR in rats. For this, however, the clearance of 99m Tc-DTPA seems well applicable in Wistar rats. (author)

  6. Metabolic clearance rate and urinary clearance of purified beta-core

    International Nuclear Information System (INIS)

    Wehmann, R.E.; Blithe, D.L.; Flack, M.R.; Nisula, B.C.

    1989-01-01

    We injected a highly purified preparation of the beta-core molecule, a fragment of hCG beta excreted in pregnancy urine, into five men and three women to determine its kinetic parameters, MCR, and urinary clearance. The beta-core molecule was distributed in an initial volume [1950 +/- 156 (mean +/- SEM) mL/m2 body surface area] approximately equal to the estimated plasma volume. Its disappearance was multiexponential on a semilogarithmic plot, with a rapid phase t1/2 of 3.5 +/- 0.7 min and a slow phase t1/2 of 22.4 +/- 4.2 min. The transit time (the mean time spent by a molecule of beta-core in transit) was 20.6 +/- 2.1 min. The MCR was 192.0 +/- 8.0 mL/min.m2 body surface area. About 5% of the injected dose of beta-core was excreted into the urine in the first 30 min after injection, and low levels of excretion persisted for up to 7 days. The urinary clearance rate of beta-core was 13.7 +/- 1.4 mL/min.m2, accounting for about 8% of the elimination of beta-core from the plasma. The beta-core immunoreactivity in serum and urine was characterized by gel filtration and three independent RIA systems to show that its properties were indistinguishable from those of the injected beta-core. Serum levels of beta-core in pregnant women were less than 0.2 ng/mL, while the amounts excreted in their urine were as much as 5 mg/day. Based on these clearance parameters of beta-core in normal subjects, less than 0.2% of the beta-core excreted in pregnancy urine is derived by urinary clearance of plasma beta-core. Therefore, more than 99% of the beta-core excreted in pregnancy urine is derived from beta-core in a compartment separate from plasma. In particular, these data indicate that there is relatively little placental secretion of beta-core into plasma and that placental secretion does not account for the vast majority of beta-core in pregnancy urine

  7. Allometric scaling for predicting human clearance of bisphenol A

    International Nuclear Information System (INIS)

    Collet, Séverine H.; Picard-Hagen, Nicole; Lacroix, Marlène Z.; Puel, Sylvie; Viguié, Catherine; Bousquet-Melou, Alain; Toutain, Pierre-Louis; Gayrard, Véronique

    2015-01-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min

  8. Allometric scaling for predicting human clearance of bisphenol A

    Energy Technology Data Exchange (ETDEWEB)

    Collet, Séverine H., E-mail: s.collet@envt.fr; Picard-Hagen, Nicole, E-mail: n.hagen-picard@envt.fr; Lacroix, Marlène Z., E-mail: m.lacroix@envt.fr; Puel, Sylvie, E-mail: s.puel@envt.fr; Viguié, Catherine, E-mail: c.viguie@envt.fr; Bousquet-Melou, Alain, E-mail: a.bousquet-Melou@envt.fr; Toutain, Pierre-Louis, E-mail: pltoutain@wanadoo.fr; Gayrard, Véronique, E-mail: v.gayrard@envt.fr

    2015-05-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min.

  9. 48 CFR 2452.237-75 - Clearance of contractor personnel.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Clearance of contractor... Clauses 2452.237-75 Clearance of contractor personnel. As prescribed in 2437.110(e), insert the following clause in solicitations and contracts. Clearance of Contractor Personnel (OCT 1999) (a) General. This...

  10. Comparative evaluation of iohexol and inulin clearance for glomerular filtration rate determinations

    International Nuclear Information System (INIS)

    Lindblad, H.G.; Berg, U.B.

    1994-01-01

    The authors have evaluated iohexol as a filtration marker in 150 children. The clearance of iohexol was compared with that of inulin or with a formula clearance. The single-sample clearance of iohexol showed a good correlation with the clearance of inulin. The clearance of iohexol correlated well with the formula clearance. The optimal blood sampling time for iohexol clearance determinations appears to be between 120 and 180 min after injection, at least in patient with relatively normal filtration rates. It is concluded that iohexol clearance is an accurate method of determining the glomerular filtration rate in clinical practice. 25 refs., 5 figs

  11. Security Clearance Tracking System

    Data.gov (United States)

    National Archives and Records Administration — SCTS supports the adjudication process of private background investigations and clearances for potential employees, contractors, interns and student workers.

  12. Centrifugal compressor tip clearance and impeller flow

    Energy Technology Data Exchange (ETDEWEB)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari [Laboratory of Fluid Dynamics, LUT School of Energy Systems, Lappeenranta University of Technology, Lappeenranta (Finland); Engeda, Abraham [Turbomachinery Laboratory, Dept. of Mechanical Engineering, Michigan State University, East Lansing (United States)

    2016-11-15

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease.

  13. Centrifugal compressor tip clearance and impeller flow

    International Nuclear Information System (INIS)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari; Engeda, Abraham

    2016-01-01

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease

  14. Impulsive response of an automatic transmission system with multiple clearances: Formulation, simulation and experiment

    Science.gov (United States)

    Crowther, Ashley R.; Singh, Rajendra; Zhang, Nong; Chapman, Chris

    2007-10-01

    Impulsive responses in geared systems with multiple clearances are studied when the mean torque excitation and system load change abruptly, with application to a vehicle driveline with an automatic transmission. First, torsional lumped-mass models of the planetary and differential gear sets are formulated using matrix elements. The model is then reduced to address tractable nonlinear problems while successfully retaining the main modes of interest. Second, numerical simulations for the nonlinear model are performed for transient conditions and a typical driving situation that induces an impulsive behaviour simulated. However, initial conditions and excitation and load profiles have to be carefully defined before the model can be numerically solved. It is shown that the impacts within the planetary or differential gears may occur under combinations of engine, braking and vehicle load transients. Our analysis shows that the shaping of the engine transient by the torque converter before reaching the clearance locations is more critical. Third, a free vibration experiment is developed for an analogous driveline with multiple clearances and three experiments that excite different response regimes have been carried out. Good correlations validate the proposed methodology.

  15. Hepatic drug clearance following traumatic injury.

    Science.gov (United States)

    Slaughter, R L; Hassett, J M

    1985-11-01

    Trauma is a complex disease state associated with physiologic changes that have the potential to alter hepatic drug clearance mechanisms. These responses include alterations in hepatic blood flow, reduction in hepatic microsomal activity, reduction in hepatic excretion processes, and changes in protein binding. Hepatic blood flow is influenced by sympathomimetic activity. Both animal and human studies demonstrate an initial reduction and subsequent increase in hepatic blood flow, which coincides with an observed increase and subsequent return to normal in serum catecholamine concentrations. Unfortunately, there are no human studies that address the importance these findings may have to the clearance processes of high intrinsic clearance compounds. Animal studies of trauma indicate that hepatic microsomal activity is depressed during the post-traumatic period. Reduction in the hepatic clearance of antipyrine, a model low intrinsic compound, has also been demonstrated in animal models of trauma. In addition to these effects, hepatic excretion of substances such as indocyanine green and bilirubin have been demonstrated to be impaired in both traumatized animals and humans. Finally, substantial increases in the serum concentration of the binding protein alpha 1-acid glycoprotein occur in trauma patients. This has been reported to be associated with subsequent decreases in the free fraction of lidocaine and quinidine. In addition to changing serum drug concentration/response relationships, the pharmacokinetic behavior of drugs bound to alpha 1-acid glycoprotein should also change. Preliminary observations in our laboratory in a dog model of surgically-induced trauma have shown a reduction in the total clearance of lidocaine and reduction in free lidocaine concentration.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Diminished creatinine clearance in anorexia nervosa: reversal with weight gain.

    OpenAIRE

    Boag, F; Weerakoon, J; Ginsburg, J; Havard, C W; Dandona, P

    1985-01-01

    To assess whether patients with anorexia nervosa have abnormalities in creatinine clearance, we measured plasma creatinine concentration, urinary creatinine excretion, and creatinine clearance in 10 patients with anorexia nervosa before and during treatment. Urinary creatinine excretion and creatinine clearance were diminished in all patients. Nine patients had significant decreases in their plasma creatinine and creatinine clearance was increased even when corrected for body weight and body ...

  17. Cerebrospinal Fluid Clearance in Alzheimer Disease Measured with Dynamic PET.

    Science.gov (United States)

    de Leon, Mony J; Li, Yi; Okamura, Nobuyuki; Tsui, Wai H; Saint-Louis, Les A; Glodzik, Lidia; Osorio, Ricardo S; Fortea, Juan; Butler, Tracy; Pirraglia, Elizabeth; Fossati, Silvia; Kim, Hee-Jin; Carare, Roxana O; Nedergaard, Maiken; Benveniste, Helene; Rusinek, Henry

    2017-09-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Dynamic PET with 18 F-THK5117, a tracer for tau pathology, was used to estimate the ventricular CSF time-activity as a biomarker for CSF clearance. We tested 3 hypotheses: extracranial CSF is detected at the superior turbinates; CSF clearance is reduced in AD; and CSF clearance is inversely associated with amyloid deposition. Methods: Fifteen subjects, 8 with AD and 7 normal control volunteers, were examined with 18 F-THK5117. Ten subjects additionally underwent 11 C-Pittsburgh compound B ( 11 C-PiB) PET scanning, and 8 were 11 C-PiB-positive. Ventricular time-activity curves of 18 F-THK5117 were used to identify highly correlated time-activity curves from extracranial voxels. Results: For all subjects, the greatest density of CSF-positive extracranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinate CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET-measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  18. Analysis of conservativity analysis for clearance levels. Final report

    International Nuclear Information System (INIS)

    Deckert, A.; Thierfeldt, S.

    1997-07-01

    When deriving clearance levels for material from nuclear installations it is necessary to proceed with a certain degree of conservativity. This can, however, differ between various sets of clearance levels leading to inconsistencies between clearance pathways. The aim of the work therefore is to compare levels of conservativity for the following two sets of clearance levels: clearance levels for disposal as conventional waste and for metallic materials for recycling/reuse. A method was developed to quantify the degree of conservativity and make it comparable. The actual and future situation for disposal of (conventional) wastes in Germany was analysed. In addition, the masses, nuclide vectors, geographical distribution etc. for slightly radioactive material being cleared for conventional disposal was analysed and modelled and the resulting dose distributions were calculated. The values for the clearance levels were taken from the 1995 recommendation by the German Commission on Radiation Protection (SSK). By using realistic scenarios, the exposure was calculated for the personnel on the landfills and for persons of the general public being exposed via groundwater pathways. It could be shown that the trivial dose range will not be exceeded even if the masses of cleared material per landfill site exceed 100 Mg/a. Because of the types and distribution of nuclear installations in Germany and because of the nuclide vectors it is therefore not necessary to limit the masses per landfill sites. Clearance levels that are determined by the exposure pathways external exposure to and the inhalation of dust by the landfill personnel show a similar level of conservativity as those for metal scrap. This means that the clearance levels for gamma emitting nuclides are not overly restrictive. Although radiologically justified, raising the clearance levels would not lead to an increase of the material quantities because other nuclides of the respective nuclide vectors are limiting. In

  19. A novel gripper design for multi hand tools grasping under tight clearance constraints and external torque effect

    KAUST Repository

    Shaqura, Mohammad

    2017-08-29

    A robotic multi tool gripper design and implementation is presented in this paper. The proposed design targets applications where an actuation task is performed using a wide selection of standard hand tools. The manipulation motion is assumed to be rotational which requires a firm grip to account for external torque on the grasped tool. The setup is assumed to be a conventional workshop panel with hand tools being hanged close to each other, which constraints lateral clearance around the target, and near the wall of the panel, which constraints the depth clearance. Off the shelf grippers are mostly heavy and bulky which make them unsuitable for these requirements. Moreover, they are not optimized in terms of power consumption, simplicity and compactness. These generic grippers are mostly designed for pick and place tasks where no external torques other than those caused by the object weight affects the gripper. The design challenge involves building a gripper that is capable of operating in limited clearance space, firmly grip a variety of standard hand tools with different sizes and shapes. The proposed design is optimized for these objectives and offers a low cost and power consumption solution. The design has been validated in lab and outdoor experiments and has been deployed in real operating platform used in an international robotics competition.

  20. Numerical investigation of hub clearance flow in a Kaplan turbine

    Science.gov (United States)

    Wu, H.; Feng, J. J.; Wu, G. K.; Luo, X. Q.

    2012-11-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  1. Numerical investigation of hub clearance flow in a Kaplan turbine

    International Nuclear Information System (INIS)

    Wu, H; Feng, J J; Wu, G K; Luo, X Q

    2012-01-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  2. Determination of renal clearance of 131I-hippuran

    International Nuclear Information System (INIS)

    Ridzon, S.

    1982-01-01

    The author presents his own method for the determination of total renal clearance of 131 I-hippuran under conditions of its diminishing plasma concentration following single intravenous administration. Total renal clearance is determined as the ratio of the amount of activity excreted into the urine over a certain time interval and of the area limited by the curve of activity decrease in plasma and by the time axis in the corresponding interval. The results are demonstrated in five investigated healthy subjects, and very good agreement of the calculated values of total renal clearance for different time intervals in the same subject is pointed out. When isotope nephrography is simultaneously performed, the method allows to determine also the values of isolated renal clearance for each kidney separately. (author)

  3. Inherited Disorders of Bilirubin Clearance

    Science.gov (United States)

    Memon, Naureen; Weinberger, Barry I; Hegyi, Thomas; Aleksunes, Lauren M

    2016-01-01

    Inherited disorders of hyperbilirubinemia may be caused by increased bilirubin production or decreased bilirubin clearance. Reduced hepatic bilirubin clearance can be due to defective 1) unconjugated bilirubin uptake and intrahepatic storage, 2) conjugation of glucuronic acid to bilirubin (e.g. Gilbert syndrome, Crigler-Najjar syndrome, Lucey-Driscoll syndrome, breast milk jaundice), 3) bilirubin excretion into bile (Dubin-Johnson syndrome), or 4) conjugated bilirubin re-uptake (Rotor syndrome). In this review, the molecular mechanisms and clinical manifestations of these conditions are described, as well as current approaches to diagnosis and therapy. PMID:26595536

  4. Approaches towards establishing of clearance levels in Japan

    International Nuclear Information System (INIS)

    Sumitani, N.; Watanabe, I.; Okoshi, M.

    1998-01-01

    It is important to establish necessary regulatory systems for decommissioning waste management, especially to establish clearance levels from regulatory control. To establish the regulatory systems, the Nuclear Safety Commission (NSC) has been discussing the unconditional clearance levels for materials from nuclear reactors since May 1997. The NSC tries to derive unconditional clearance levels for the materials such as concrete and ferrous metal, arising from nuclear reactor decommissioning. In the derivation, both disposal and recycle/reuse of the materials are considered. Typical scenarios and parameter values for dose estimation are selected considering the Japanese natural and social conditions. Preliminary clearance levels were derived from 10 μSv/yr of individual dose criterion and deterministic analysis. For most radionuclides, the preliminary results are the same order of magnitude recommended in IAEA-TECDOC-855. Some radionuclides such as β emitters, however, are different order of magnitude from those recommended in IAEA-TECDOC-855. It is necessary that international organizations lead the discussions on the clearance levels to conclude final consensus. (author)

  5. Green technology; only Forest Clearance is needed

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. How was Forest Clearance granted before the procedures for constitution of ESZ was completed? How was Forest Clearance granted before the procedures for constitution of ESZ was completed? How was land in Murmurwadi still under litigation made available? How was ...

  6. A novel approach to achieving modular retrovirus clearance for a parvovirus filter.

    Science.gov (United States)

    Stuckey, Juliana; Strauss, Daniel; Venkiteshwaran, Adith; Gao, Jinxin; Luo, Wen; Quertinmont, Michelle; O'Donnell, Sean; Chen, Dayue

    2014-01-01

    Viral filtration is routinely incorporated into the downstream purification processes for the production of biologics produced in mammalian cell cultures (MCC) to remove potential viral contaminants. In recent years, the use of retentive filters designed for retaining parvovirus (~20 nm) has become an industry standard in a conscious effort to further improve product safety. Since retentive filters remove viruses primarily by the size exclusion mechanism, it is expected that filters designed for parvovirus removal can effectively clear larger viruses such as retroviruses (~100 nm). In an attempt to reduce the number of viral clearance studies, we have taken a novel approach to demonstrate the feasibility of claiming modular retrovirus clearance for Asahi Planova 20N filters. Porcine parvovirus (PPV) and xenotropic murine leukemia virus (XMuLV) were co-spiked into six different feedstreams and then subjected to laboratory scale Planova 20N filtration. Our results indicate that Planova 20N filters consistently retain retroviruses and no retrovirus has ever been detected in the filtrates even when significant PPV breakthrough is observed. Based on the data from multiple in-house viral validation studies and the results from the co-spiking experiments, we have successfully claimed a modular retrovirus clearance of greater than 6 log10 reduction factors (LRF) to support clinical trial applications in both USA and Europe. © 2013 American Institute of Chemical Engineers.

  7. Nuclear regulation. NRC's security clearance program can be strengthened

    International Nuclear Information System (INIS)

    Fultz, Keith O.; Kruslicky, Mary Ann; Bagnulo, John E.

    1988-12-01

    Because of the national security implications of its programs, the Nuclear Regulatory Commission (NRC) investigates the background of its employees and consultants as well as others to ensure that they are reliable and trustworthy. If the investigation indicates that an employee will not endanger national security, NRC grants a security clearance that allows access to classified information, material, and facilities. NRC also requires periodic checks for some clearance holders to ensure their continued clearance eligibility. The Chairman, Subcommittee on Environment, Energy, and Natural Resources, House Committee on Government Operations, asked GAO to review NRC's personnel security clearance program and assess the procedures that NRC uses to ensure that those who operate nuclear power plants do not pose a threat to the public. The Atomic Energy Act of 1954 requires NRC to conduct background investigations of its employees and consultants as well as others who have access to classified information, material, or facilities. To do this, NRC established a personnel security clearance program. Under NRC policies, a security clearance is granted after the Office of Personnel Management (OPM) or the Federal Bureau of Investigation checks the background of those applying for an NRC clearance. NRC also periodically reassesses the integrity of those holding the highest level clearance. NRC employees, consultants, contractors, and licensees as well as other federal employees hold approximately 10,600 NRC clearances. NRC does not grant clearances to commercial nuclear utility employees unless they require access to classified information or special nuclear material. However, the utilities have voluntarily established screening programs to ensure that their employees do not pose a threat to nuclear plants. NRC faces a dilemma when it hires new employees. Although its policy calls for new hires to be cleared before they start work, the security clearance process takes so long

  8. Peritoneal clearances in hypertensive CAPD patients after oral administration of clonidine, enalapril, and nifedipine.

    Science.gov (United States)

    Favazza, A; Motanaro, D; Messa, P; Antonucci, F; Gropuzzo, M; Mioni, G

    1992-01-01

    The authors investigated whether the reduction of arterial pressure, induced by the oral administration of clonidine (CLO), enalapril (EN), and nifedipine (NIF), has any effect on peritoneal transport rates. The study was performed in nine hypertensive patients undergoing continuous ambulatory peritoneal dialysis (CAPD). The patients were submitted to administration of CLO, EN, and NIF, each in randomized succession for two weeks, after withdrawal of any hypotensive therapy for eight days (washout period). The nine patients underwent a four-hour dwell exchange using a 2.27 g/dL glucose two-liter bag after washout and after each hypotensive period. The following parameters were analyzed: mean arterial pressure (MAP), performed in the sitting position; net ultrafiltration; effluent/initial dialysate glucose ratio (GL D/Do); peritoneal clearance of K, BUN, creatinine (Cr), phosphate, beta-2 microglobulin (beta 2), total proteins, and the ratio between beta 2 and Cr clearance. Moreover, residual renal Cr and beta 2 clearances were analyzed. The three drugs significantly reduced MAP at a similar rate. The peritoneal transport parameters after CLO were similar to the results in the washout period. On the contrary, after EN and NIF therapy, Cr and beta 2 clearances were significantly increased, and GL D/Do decreased in comparison to the washout period. The other peritoneal transport parameters after EN and NIF were similar to the washout period. Residual renal Cr and beta 2 clearances after the three drugs were similar to those in the washout. these data suggest that after two weeks of therapy with EN and NIF, glucose, Cr, and beta 2 peritoneal transports are influenced by these hypotensive drugs irrespective of the effect on the arterial pressure.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Voltammetric and Mathematical Evidence for Dual Transport Mediation of Serotonin Clearance In Vivo

    Science.gov (United States)

    Wood, Kevin M.; Zeqja, Anisa; Nijhout, H. Frederik; Reed, Michael C.; Best, Janet; Hashemi, Parastoo

    2014-01-01

    The neurotransmitter serotonin underlies many of the brain’s functions. Understanding serotonin neurochemistry is important for improving treatments for neuropsychiatric disorders such as depression. Antidepressants commonly target serotonin clearance via serotonin transporters (SERTs) and have variable clinical effects. Adjunctive therapies, targeting other systems including serotonin autoreceptors, also vary clinically and carry adverse consequences. Fast scan cyclic voltammetry (FSCV) is particularly well suited for studying antidepressant effects on serotonin clearance and autoreceptors by providing real-time chemical information on serotonin kinetics in vivo. However, the complex nature of in vivo serotonin responses makes it difficult to interpret experimental data with established kinetic models. Here, we electrically stimulated the mouse medial forebrain bundle (MFB) to provoke and detect terminal serotonin in the substantia nigra reticulata (SNr). In response to MFB stimulation we found three dynamically distinct serotonin signals. To interpret these signals we developed a computational model that supports two independent serotonin reuptake mechanisms (high affinity, low efficiency reuptake mechanism and low affinity, high efficiency reuptake system) and bolsters an important inhibitory role for the serotonin autoreceptors. Our data and analysis, afforded by the powerful combination of voltammetric and theoretical methods, gives new understanding of the chemical heterogeneity of serotonin dynamics in the brain. This diverse serotonergic matrix likely contributes to clinical variability of antidepressants. PMID:24702305

  10. A study for promoting measures of social acceptance on clearance system

    International Nuclear Information System (INIS)

    Okoshi, Minoru; Torii, Hiroyuki; Fujii, Yasuhiko

    2007-01-01

    Clearance is one of the useful concepts to manage large amounts of slightly contaminated solid radioactive materials generated from the decommissioning of nuclear facilities. Cleared materials are expected to be disposed of as conventional wastes or recycled to produce consumer goods. In Japan, the legal frame-work for clearance was established in 2005 by amending the Law to regulate nuclear materials, reactors and so on. However, it is not so clear whether the general public understands clearance well. In this paper, major concerns about clearance from the general public are analyzed based on the public comments for reports on clearance prepared by the Nuclear Safety Commission and the Nuclear Institute Safety Agency. The major anxieties for clearance expressed by the general public are the safety of clearance, unknown factors of radiation effects, possibilities of excess radiation exposure due to inadequate measurements of radioactivities and fairness in decision making. In order to deal with those anxieties, some countermeasures including the confidence in nuclear operators and regulatory authorities and controllability of clearance by the general public are discussed to promote the social acceptance of clearance by the general public. (author)

  11. Development of a computer system for support and documentation of clearance of buildings of nuclear installations - 59278

    International Nuclear Information System (INIS)

    Winkler, Christoph; Woerlen, Stefan; Thierfeldt, Stefan; Schartmann, Frank

    2012-01-01

    Clearance of buildings of nuclear installations in Germany has to comply with general requirements laid down in Section 29 of the German Radiation Protection Ordinance (RPO; Strahlenschutzverordnung), clearance levels as stipulated in Table 1 of Annex III RPO and technical guidance given in the technical standard DIN 25457. Clearance procedures are usually proposed by the licensee and are made part of a decommissioning licence after appropriate review by the authorities. The clearance procedures consist of a radiological characterisation of the various parts of the buildings, a decontamination step if necessary, followed by measurements for checking the success of decontamination, and the actual decision measurements for demonstrating compliance with clearance levels. These three steps rely on various measurement methods, selected depending on the relevant radionuclides to be measured, like sampling with subsequent gamma spectrometry (and if necessary separate evaluation of beta and alpha emitting nuclides), measurements with surface contamination monitory and in situ gamma spectrometry. For a nuclear power plant, the number of samples taken during this procedure can easily reach a few 10, 000, while the number of single measurements can reach several 100, 000 single surface measurements and several 10, 000 measurements with in situ gamma spectrometry. This large number of data together with the correct interpretation according to the valid nuclide vector, the penetration depth of the contamination, the correction for radioactive decay etc have to be managed, which is a error-prone process if carried out manually or with insufficient support by customised software. For this reason, a versatile software tool has been developed by Brenk Systemplanung GmbH that supports the operator in all aspects of clearance of buildings, based on the extensive experience with various clearance procedures in nuclear power plants that Brenk Systemplanung has carried out in the past

  12. Axial compressor blade design for desensitization of aerodynamic performance and stability to tip clearance

    Science.gov (United States)

    Erler, Engin

    of the local blade passage. These flow features are isolated and validated based on the reference rotor design through changes in the inlet total pressure condition to alter incoming flow momentum and blade number count to change double leakage rate. In terms of flow mechanism, double leakage is shown to be detrimental to performance and stability, and its proportional increase with tip clearance size explains the sensitivity increase in the presence of double leakage and, conversely, the desensitization effect of reducing or eliminating double leakage. The increase in incoming meridional momentum in the tip region reduces sensitivity to tip clearance through its reduction of double leakage as well as through improved mixing with tip clearance flow, as demonstrated by an analytical model without double leakage flow. The above results imply that any blade design strategy that exploits the two desensitizing flow features would reduce the performance and stability sensitivity to tip clearance size. The increase of the incoming meridional momentum can be achieved through forward chordwise sweep of the blade. The reduction of double leakage without changing blade pitch can be obtained by decreasing the blade stagger angle in the tip region. Examples of blade designs associated with these strategies are shown through CFX simulations to be successful in reducing sensitivity to tip clearance size.

  13. Intraarticular volume and clearance in human synovial effusions

    International Nuclear Information System (INIS)

    Wallis, W.J.; Simkin, P.A.; Nelp, W.B.; Foster, D.M.

    1985-01-01

    Intraarticular volumes were measured by radiolabeled albumin (RISA) distribution in chronic knee effusions from 11 rheumatoid arthritis patients and 9 osteoarthritis patients. Volumes of synovial fluid obtained at joint aspiration were substantially less than those found by RISA dilution. Up to 24 hours was needed for full distribution of RISA throughout the intraarticular compartment. Measured 123I and RISA radioactivity over the knee described monoexponential rate constants, lambda (minute-1). The clearance of 123I and RISA from synovial effusions was derived by the formulation volume (ml) X lambda (minute-1) = clearance (ml/minute). RISA clearance in rheumatoid effusions was significantly greater than that found in osteoarthritis effusions. Intraarticular volume and isotope clearance were easily quantified and provide measures for further evaluating the microvascular physiology of synovial effusions

  14. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.

    2003-01-01

    Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

  15. The tear turnover and tear clearance tests - a review.

    Science.gov (United States)

    Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño

    2018-03-01

    The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  17. Successful treatment of laser induced hypopigmentation with narrowband ultraviolet B targeted phototherapy

    Directory of Open Access Journals (Sweden)

    Venkataram Mysore

    2013-01-01

    Full Text Available Q-switched 1064 nm neodymium-doped yttrium aluminium garnet (Qs 1064 nm Nd: YAG laser plays an important role in the treatment of pigmentary skin disorders, including tattoos. Although it has high efficacy and safety, adverse effect like hypopigmentation may occur causing anxiety to patients. We present a case report of Qs 1064 nm Nd: YAG laser induced hypopigmentation which was successfully treated with ultraviolet B targeted phototherapy, with rapid and satisfactory re-pigmentation.

  18. Effect of clearance on cartilage tribology in hip hemi-arthroplasty.

    Science.gov (United States)

    Lizhang, Jia; Taylor, Simon D; Jin, Zhongmin; Fisher, John; Williams, Sophie

    2013-12-01

    Hemi-arthroplasty of the hip (an artificial femoral head articulating against the natural acetabulum) is used to treat fractured necks of femur; however, there is evidence that articulation causes erosion of the cartilage, resulting in pain for the patient. Parameters that may influence this cartilage erosion include head material and roughness, clearance between the head and acetabulum and activity levels of the patient. This study has assessed the effect of clearance of hemi-arthroplasty articulations on the contact stress, friction and cartilage deformation in an in vitro tribological simulation of the hemi-arthroplasty joint that applied dynamic loads and motion. It has been demonstrated that peak contact stress increased from 5.6 to 10.6 MPa as radial clearance increased from small (1.8 mm). In all samples, friction factor increased with time and was significantly less with extra-large clearances compared to small (<0.6 mm), medium (0.6-1.2 mm) and large (1.2-1.8 mm) clearances. The cartilage deformation observed was significantly greater in acetabulum samples paired to give small or extra-large clearances compared to those with medium or large clearances.

  19. LKB1 Regulates Mitochondria-Dependent Presynaptic Calcium Clearance and Neurotransmitter Release Properties at Excitatory Synapses along Cortical Axons.

    Science.gov (United States)

    Kwon, Seok-Kyu; Sando, Richard; Lewis, Tommy L; Hirabayashi, Yusuke; Maximov, Anton; Polleux, Franck

    2016-07-01

    Individual synapses vary significantly in their neurotransmitter release properties, which underlie complex information processing in neural circuits. Presynaptic Ca2+ homeostasis plays a critical role in specifying neurotransmitter release properties, but the mechanisms regulating synapse-specific Ca2+ homeostasis in the mammalian brain are still poorly understood. Using electrophysiology and genetically encoded Ca2+ sensors targeted to the mitochondrial matrix or to presynaptic boutons of cortical pyramidal neurons, we demonstrate that the presence or absence of mitochondria at presynaptic boutons dictates neurotransmitter release properties through Mitochondrial Calcium Uniporter (MCU)-dependent Ca2+ clearance. We demonstrate that the serine/threonine kinase LKB1 regulates MCU expression, mitochondria-dependent Ca2+ clearance, and thereby, presynaptic release properties. Re-establishment of MCU-dependent mitochondrial Ca2+ uptake at glutamatergic synapses rescues the altered neurotransmitter release properties characterizing LKB1-null cortical axons. Our results provide novel insights into the cellular and molecular mechanisms whereby mitochondria control neurotransmitter release properties in a bouton-specific way through presynaptic Ca2+ clearance.

  20. Modified Augmented Renal Clearance Score Predicts Rapid Piperacillin and Tazobactam Clearance in Critically Ill Surgery and Trauma Patients

    Science.gov (United States)

    2014-04-24

    collision; VAP , ventilator-associated pneumonia. TABLE 2. PK Parameter Estimates for Free Piperacillin and Tazobactam in Patients Stratified by ARC Score...SOFA score are typically generated during routine care of the most severely ill patients . Positive screening test results (high ARC scores) can be...Modified Augmented Renal Clearance score predicts rapid piperacillin and tazobactam clearance in critically ill surgery and trauma patients Kevin S

  1. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in CF Clinical Care Guidelines Cystic Fibrosis-Related Diabetes Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care Guidelines Chronic Medications to Maintain Lung ...

  2. Acupuncture promotes mTOR-independent autophagic clearance of aggregation-prone proteins in mouse brain.

    Science.gov (United States)

    Tian, Tian; Sun, Yanhong; Wu, Huangan; Pei, Jian; Zhang, Jing; Zhang, Yi; Wang, Lu; Li, Bin; Wang, Lihua; Shi, Jiye; Hu, Jun; Fan, Chunhai

    2016-01-21

    Acupuncture has historically been practiced to treat medical disorders by mechanically stimulating specific acupoints with fine needles. Despite its well-documented efficacy, its biological basis remains largely elusive. In this study, we found that mechanical stimulation at the acupoint of Yanglingquan (GB34) promoted the autophagic clearance of α-synuclein (α-syn), a well known aggregation-prone protein closely related to Parkinson's disease (PD), in the substantia nigra par compacta (SNpc) of the brain in a PD mouse model. We found the protein clearance arose from the activation of the autophagy-lysosome pathway (ALP) in a mammalian target of rapamycin (mTOR)-independent approach. Further, we observed the recovery in the activity of dopaminergic neurons in SNpc, and improvement in the motor function at the behavior level of PD mice. Whereas acupuncture and rapamycin, a chemical mTOR inhibitor, show comparable α-syn clearance and therapeutic effects in the PD mouse model, the latter adopts a distinctly different, mTOR-dependent, autophagy induction process. Due to this fundamental difference, acupuncture may circumvent adverse effects of the rapamycin treatment. The newly discovered connection between acupuncture and autophagy not only provides a new route to understanding the molecular mechanism of acupuncture but also sheds new light on cost-effective and safe therapy of neurodegenerative diseases.

  3. What is Working Today: Success stories in marketing, rights management, and more

    OpenAIRE

    Leary, Heather; Mower, Allyson; Armstrong, Michelle

    2009-01-01

    This panel session will be a discussion of success stories by various IR Coordinators in their daily work with marketing, copyright clearance, workflow, distinctions between the Digital Library and IR, and more.

  4. 2015 Annual Report on Security Clearance Determinations

    Science.gov (United States)

    2016-06-28

    only have delegated investigative authority over their civilian employee population and therefore, can only report the overall timeliness for that...completed or pending security clearance determinations for government employees and contractors during the preceding fiscal year that have taken longer...Clearance Determinations to Congress. The IAA directs this report to include the number of United States Government (USG) employees who held a

  5. Dynamic modelling and experimental study of cantilever beam with clearance

    International Nuclear Information System (INIS)

    Li, B; Jin, W; Han, L; He, Z

    2012-01-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  6. Dynamic modelling and experimental study of cantilever beam with clearance

    Science.gov (United States)

    Li, B.; Jin, W.; Han, L.; He, Z.

    2012-05-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  7. BAG3 facilitates the clearance of endogenous tau in primary neurons.

    Science.gov (United States)

    Lei, Zhinian; Brizzee, Corey; Johnson, Gail V W

    2015-01-01

    Tau is a microtubule associated protein that is found primarily in neurons, and in pathologic conditions, such as Alzheimer's disease (AD) it accumulates and contributes to the disease process. Because tau plays a fundamental role in the pathogenesis of AD and other tauopathies, and in AD mouse models reducing tau levels improves outcomes, approaches that facilitate tau clearance are being considered as therapeutic strategies. However, fundamental to the development of such interventions is a clearer understanding of the mechanisms that regulate tau clearance. Here, we report a novel mechanism of tau degradation mediated by the co-chaperone BAG3. BAG3 has been shown to be an essential component of a complex that targets substrates to the autophagy pathway for degradation. In rat primary neurons, activation of autophagy by inhibition of proteasome activity or treatment with trehalose resulted in significant decreases in tau and phospho-tau levels. These treatments also induced an upregulation of BAG3. Proteasome inhibition activated JNK, which was responsible for the upregulation of BAG3 and increased tau clearance. Inhibiting JNK or knocking down BAG3 blocked the proteasome inhibition-induced decreases in tau. Further, BAG3 overexpression alone resulted in significant decreases in tau and phospho-tau levels in neurons. These results indicate that BAG3 plays a critical role in regulating the levels of tau in neurons, and interventions that increase BAG3 levels could provide a therapeutic approach in the treatment of AD. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... many challenges, including medical, social, and financial. By learning more about how you can manage your disease every day, you can ultimately help find a ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic ...

  9. Refrigeration system with clearance seals

    International Nuclear Information System (INIS)

    Holland, N. J.

    1985-01-01

    In a refrigeration system such as a split Stirling system, fluid seals associated with the reciprocating displacer are virtually dragless clearance seals. Movement of the displacer relative to the pressure variations in the working volume of gas is retarded by a discrete braking element. Because it is not necessary that the brake providing any sealing action, the brake can be designed for greater durability and less dependence on ambient and operating temperatures. Similarly, the clearance seal can be formed of elements having low thermal expansion such that the seal is not temperature dependent. In the primary embodiments the braking element is a split friction brake

  10. Chaos vibration of pinion and rack steering trapezoidal mechanism containing two clearances

    Science.gov (United States)

    Wei, Daogao; Wang, Yu; Jiang, Tong; Zheng, Sifa; Zhao, Wenjing; Pan, Zhijie

    2017-08-01

    The multi-clearances of breaking type steering trapezoidal mechanism joints influences vehicle steering stability. Hence, to ascertain the influence of clearance value on steering stability, this paper takes the steering mechanism of a certain vehicle type as a prototype that can be simplified into a planar six-bar linkage, then establishes the system dynamic differential equations after considering the two clearances of tie rods and the steering knuckle arms. The influence of the clearance parameters on the movement stability of the steering mechanism is studied using a numerical computation method. Results show that when the two clearances are equal, the planar movement of the tie rods changes from period-doubling to chaos as the clearances increase. When the two clearances are 0.25 mm and 1.5 mm respectively, the planar movements of the two side tie rods come into chaos, causing the steering stability to deteriorate. Moreover, with the increase of clearances, turning moment fluctuates more intensively and the peak value increases.

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... decisions about your health care. CF Genetics: The Basics CF Mutations Video Series Find Out More About ... of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing and ...

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: March 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  14. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway ... on their own. Share Facebook Twitter Email More options Print Share Facebook Twitter Email Print Permalink All ...

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: June 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Physical Therapy Coughing and Huffing High-Frequency Chest Wall Oscillation Positive Expiratory Pressure Clinical Trials Clinical Trials ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  18. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in part to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of ... a cure for CF and supports a broad range of research initiatives to tackle the disease from ...

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care ... attack bacteria. Choose What's Best for You Your respiratory therapist or another member of your CF care ...

  1. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing ... Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation ( ...

  2. Measurement with nasal scintigraphy of nasal mucociliary clearance in normal man

    International Nuclear Information System (INIS)

    Murai, Sumiko

    1989-01-01

    Nasal mucociliary function was evaluated by nasal scintigraphy in normal subjects. A microdrop of HSA or saline labelled with 99m Tc was dripped into the middle part of each middle meatus in the nasal cavity and its clearance was observed by scinticamera. The accumulated concentration of RI was determined every 30 seconds for 10 minutes. The changes of accumulated concentration were studied, and a curve of decreasing RI-counts was obtained, with the 'clearance rate' defined as 100% for the count at the initial 30 seconds and 'half time' as the time when radioactivity was reduced to one half the initial count. Nasal resistance was measured by rhinomanometry with the oscillation method. In nonsmokers, 10μl of saline was cleared (78.0±10.4%) significantly faster than 10μl of HSA (59.9±24.6%), and there was no significant difference in the clearance between 10μl and 5μl of HSA (55.9±27.7%). In smakers, the mucociliary clearance of 10μl of HSA and saline was significantly lower than in nonsmokers. The clearance of 10μl of HSA reflects a pathological state much better than that of 5μl. In nonsmokers, there is a significant negative correlation between nasal resistance and clearance rate, suggesting that the more patent the nose, the faster the mucociliary clearance. When both nostrils were closed, the clearance rate was significantly depressed. When one nostril was closed, there was no significant effect on clearance. Nasal resistance was decreased by exercise with a bicycle ergometer. Nasal mucociliary clearance was slightly decreased after exercise but not significantly so. (J.P.N.)

  3. 78 FR 77027 - Overhead Clearance (Air-Draft) Accidents

    Science.gov (United States)

    2013-12-20

    ... No. USCG-2013-0466] Overhead Clearance (Air-Draft) Accidents AGENCY: Coast Guard, DHS. ACTION... clearance (air-draft) accidents. In its petition, which calls for vessel masters to be provided with... accidents that it says were avoidable and that resulted in damage to or destruction of waterway...

  4. The role of clearance in Germany - release of materials, buildings and sites

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2005-01-01

    Clearance in Germany is far advanced. A complex regulatory framework exists in the Radiation Protection Ordinance (RPO/Strahlenschutzverordnung, StrlSchV) since 2001 which has replaced previous recommendations on clearance issued by the German Radiation Protection Commission (Strahlenschutzkommission, SSK). A number of options exist both for unconditional clearance (e.g. of all kinds of materials with no restrictions on the destination or future use) and for clearance for a specific purpose (e.g. recycling of metal scrap). For each clearance option there is a set of nuclide specific clearance levels which have been derived on the basis of the 10 Sv/a individual dose criterion using complex radiological models which are tailored to the respective material cycles (metal scrap, buildings, building rubble, waste for disposal, sites). The clearance levels have been thoroughly reviewed by the SSK. An extensive comparison to sets of clearance levels used in other countries or issued as guidance by international bodies revealed that the correspondence between values is between good and acceptable taking into account country-specific approaches and special assumptions which would not necessarily pertain to German situations. Clearance is a major factor in the material management, especially of nuclear installations undergoing decommissioning. The variety of clearance options leaves the operator of a nuclear installation sufficient flexibility for optimisation of the material management. Clearance is of particular importance in a country like Germany where the estimated costs for a future repository are very high and the interim storage facilities for radioactive material are limited and costly. While the licensee is responsible for his material management, the issuance of a clearance permit is done by the regulatory body upon application. The regulators may choose to use the clearance levels and regulations as stipulated by the RPO, or to impose site-specific regulations on

  5. Whole body and regional clearances of noradrenaline and adrenaline in man

    DEFF Research Database (Denmark)

    Christensen, N J; Galbo, H; Gjerris, A

    1984-01-01

    the clearance values based on arterial and venous sampling averaged 1.4 and 2.5 l/min, respectively (p less than 0.02). The difference in clearance values was due to peripheral uptake of NA averaging 45%. The plasma appearance rate on NA averaged 2.4 nmol/min before surgery and it increased to 9.5 nmol...... we found no correlation between clearance values based on venous and arterial sampling. In other experiments we measured the influence of physical exercise in young healthy subjects on the clearance rate of plasma adrenaline (A). The clearance of A, which at rest averaged 1.9 l/min tended to increase...

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Make a Charitable Gift Our Corporate Supporters Workplace Engagement DONATE YOUR PROPERTY eCards for a Cure About ... airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... people with cystic fibrosis so that they make smart decisions about CF-related research, treatment, and access ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... CFTR Modulator Therapies Mucus Thinners Nebulizer Care at Home Vascular Access Devices PICCs and Ports Partnerships for ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  9. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    Science.gov (United States)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  10. Creatinine clearance during cimetidine administration for measurement of glomerular filtration rate

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; de Waart, D. R.; Arisz, L.

    1992-01-01

    Creatinine clearance inaccurately estimates true glomerular filtration rate (GFR) because of tubular secretion of creatinine. We studied the ability of oral cimetidine, a blocker of tubular creatinine secretion, to improve the accuracy of measuring creatinine clearance. Clearances of inulin and

  11. Depressed reticuloendothelial clearance of platelets in rats after trauma.

    Science.gov (United States)

    Kaplan, J E; Moon, D G; Minnear, F L; Saba, T M

    1984-02-01

    Platelet microembolization may contribute to microcirculatory and organ damage following trauma and shock. It is hypothesized that posttraumatic reticuloendothelial depression predisposes to such microembolization by failure to clear altered platelets from the circulation. The present study evaluated the short-term (1 h) clearance and organ localization of radiolabeled homologous damaged platelets in normal rats and in rats following sublethal Noble-Collip drum trauma. Platelets were collected in citrated platelet-rich plasma from normal rats and labeled with 51Cr in citrated saline. Platelets were altered by repeated centrifugation in protein-free medium. These platelets differed functionally and morphologically from normal platelets. Disappearance of iv injected damaged platelets conformed to a two-compartment exponential clearance. Velocity of clearance in the rapid compartment correlated with hepatic platelet localization, whereas velocity of clearance in the second compartment correlated with splenic platelet localization. Clearance rate of the rapid compartment was depressed at 1 h after trauma and elevated at 24 h. These changes were associated with a decrease in hepatic platelet localization at 1 h and an increase above normal at 24 h. Splenic platelet localization was decreased by 3 h following trauma. Pulmonary platelet localization was increased at all times following trauma. It is concluded that the posttrauma state is associated with a defect in the reticuloendothelial system clearance of altered platelets, which may augment embolization of platelets in the lung.

  12. Intercalibration of mussel Mytilus edulis clearance rate measurements

    NARCIS (Netherlands)

    Kjerulf Petersen, J.; Bougrier, S.; Smaal, A.C.; Garen, P.; Robert, S.; Larsen, J.E.N.; Brummelhuis, E.B.M.

    2004-01-01

    Clearance rate (CR) was measured in blue mussels Mytilus edulis L. from Aiguillon Bay and the Oosterschelde using 3 different methods: the flow-through method, the bio-deposition method and the indirect or clearance method. CR differed significantly as a function of the method used and of the origin

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living longer and ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  14. DOD PERSONNEL CLEARANCES: Additional OMB Actions Are Needed to Improve the Security Clearance Process

    National Research Council Canada - National Science Library

    2006-01-01

    Our independent analysis of timeliness data showed that industry personnel contracted to work for the federal government waited more than one year on average to receive top secret clearances, longer...

  15. Autophagic clearance of bacterial pathogens: molecular recognition of intracellular microorganisms.

    Science.gov (United States)

    Pareja, Maria Eugenia Mansilla; Colombo, Maria I

    2013-01-01

    Autophagy is involved in several physiological and pathological processes. One of the key roles of the autophagic pathway is to participate in the first line of defense against the invasion of pathogens, as part of the innate immune response. Targeting of intracellular bacteria by the autophagic machinery, either in the cytoplasm or within vacuolar compartments, helps to control bacterial proliferation in the host cell, controlling also the spreading of the infection. In this review we will describe the means used by diverse bacterial pathogens to survive intracellularly and how they are recognized by the autophagic molecular machinery, as well as the mechanisms used to avoid autophagic clearance.

  16. Direct measurement of first-pass ileal clearance of a bile acid in humans

    International Nuclear Information System (INIS)

    Galatola, G.; Jazrawi, R.P.; Bridges, C.; Joseph, A.E.; Northfield, T.C.

    1991-01-01

    The purpose of this study was to develop and validate a method of directly measuring ileal bile acid absorption efficiency during a single enterohepatic cycle (first-pass ileal clearance). This has become feasible for the first time because of the availability of the synthetic gamma-labeled bile acid 75Selena-homocholic acid-taurine (75SeHCAT). Together with the corresponding natural bile acid cholic acid-taurine (labeled with 14C), SeHCAT was infused distal to an occluding balloon situated beyond the ampulla of Vater in six healthy subjects. Completion of a single enterohepatic cycle was assessed by obtaining a plateau for 75SeHCAT activity proximal to the occluding balloon, which prevented further cycles. Unabsorbed 75SeHCAT was collected after total gut washout, which was administered distal to the occluding balloon. 75SeHCAT activity in the rectal effluent measured by gamma counter was compared with that of absorbed 75SeHCAT level measured by gamma camera and was used to calculate first-pass ileal clearance. This was very efficient (mean value, 96%) and showed very little variation in the six subjects studied (range, 95%-97%). A parallel time-activity course in hepatic bile for 14C and 75Se during a single enterohepatic cycle, together with a ratio of unity for 14C/75Se in samples obtained at different time intervals, suggests that 75SeHCAT is handled by the ileum like the natural bile acid cholic acid-taurine. Extrapolation of 75SeHCAT first-pass ileal clearance to that of the natural bile acid therefore seems justifiable. In a subsidiary experiment, ileal absorption efficiency per day for 75SeHCAT was also measured by scanning the gallbladder area on 5 successive days after the measurement of first-pass ileal clearance. In contrast with absorption efficiency per cycle, absorption efficiency per day varied widely (49%-86%)

  17. Assessment of renal function with the Tc-99m-MAG3 clearance

    International Nuclear Information System (INIS)

    Keske, U.; Corcles, M.; Andreessen, R.; Wilfling, M.; Roll, D.; Gahl, G.; Felix, R.

    1990-01-01

    This paper evaluates the applicability of the 99m-Tc-mercaptoacetyle-triglycine (MAG3) clearance for the documentation of renal function. Renal clearance was measured with the method of Tauxe in 699 patients during routine renal scintigraphy with 80 MBq of 99mTc-MAG3. Serum creatinine level and MAG3 clearance show an inverse correlation. Patients with an elevated serum creatinine level constantly have a lowered MAG3 clearance and vice versa. For creatinine values lower than 1.8 mg/dL, minor changes in creatinine level are accompanied by large changes in MAG3 clearance. Age (in years) dependence of MAG3 clearance was evaluated in 487 patients who showed no evidence of impaired renal function

  18. Effects of heart rate on myocardial thallium-201 uptake and clearance

    International Nuclear Information System (INIS)

    Nordrehaug, J.E.; Danielsen, R.; Vik-Mo, H.

    1989-01-01

    The effects of heart rate on the myocardial uptake and clearance of 201 Tl were studied prospectively in seven healthy men, mean age 43 +/- 7 (s.d.) yr. Initial and delayed (3 hr) thallium images were obtained in three views after three bicycle exercise tests: to maximal, 80% and 60% of predicted maximal heart rate. The mean of three views initial myocardial 201 Tl uptake was higher at maximal than at both 80% and 60% of predicted maximal heart rate, being 81% (p less than 0.01) and 60% (p less than 0.01) of maximal activity, respectively. The myocardial activity in the delayed images was identical. There was a linear relationship between heart rate and the initial myocardial activity, r = 0.86 (p less than 0.001). The mean (range) 201 Tl clearance was 58% (51-65), 47% (34-56), and 34% (22-49) (all differences p less than 0.01), respectively. Concordance among the three individual views in estimating clearance was best for the highest exercise level. There was a linear relationship between heart rate and clearance, r = 0.80 (p less than 0.001). Clearance was altered by only 1.67 x 10%/heart bpm (0.024 hr/heart beat). Clearance in the liver, spleen and lungs increased at submaximal exercise levels. Thus, a linear relationship between heart rate and clearance is the result of changes in the initial exercise myocardial 201 Tl activity. Submaximal exercise may reduce reproducibility of clearance estimation, and the change of myocardial clearance with heart rate seems less than previously suggested

  19. Factors affecting lower calyceal stone clearance after Extracorporeal ...

    African Journals Online (AJOL)

    shanker

    have been identified [1,3]. These include stone characteristics, the type of lithotripter used, LPC anatomy and body habitus. For iso- lated LPC stones, the pelvicalyceal angle, infundibulum length and width are considered important determinants for stone clearance. The impact of body habitus on stone clearance has so far ...

  20. Delayed clearance of triglyceride‐rich lipoproteins in young, healthy obese subjects†

    Science.gov (United States)

    Goll, R.; Lekahl, S.; Moen, O. S.; Florholmen, J.

    2015-01-01

    Summary Obesity is associated with the metabolic syndrome. The aims were, first, to study the postprandial triglyceride clearance in young, healthy obese subjects and, second, to investigate if fasting triglycerides can predict delayed postprandial triglyceride clearance. Eighteen apparently healthy, obese subjects with no clinical signs of metabolic disturbances participated. Controls were age‐ and sex‐matched, healthy, normal weight subjects. Subclinical markers of metabolic disturbances were assessed by measuring postprandial triglycerides in serum and in chylomicrons by oral fat tolerance test. Postprandial triglyceride clearance for 8 h was assessed indirectly as removal of the lipid from serum during the oral fat tolerance test. Insulin resistance was measured by the homeostasis model assessment of insulin resistance (HOMA‐IR). Twelve (66%) of the apparently healthy obese individuals had insulin resistance measured by HOMA‐IR. There was a delayed clearance of serum triglycerides and chylomicron triglycerides at 6 h when compared with the control group, while, at 8 h, the differences were only detected for the chylomicron triglyceride clearance. Triglyceride response was significantly greater in the obese subjects. Fasting triglycerides in upper normal level predicted a delayed postprandial triglyceride clearance and insulin resistance. In young, apparently healthy obese subjects early metabolic disturbances including insulin resistance and delayed postprandial triglyceride clearance can be detected. Fasting serum triglyceride in upper normal level predicted delayed postprandial triglyceride clearance and insulin resistance. PMID:26469529

  1. Delayed clearance of triglyceride-rich lipoproteins in young, healthy obese subjects.

    Science.gov (United States)

    Larsen, M A; Goll, R; Lekahl, S; Moen, O S; Florholmen, J

    2015-12-01

    Obesity is associated with the metabolic syndrome. The aims were, first, to study the postprandial triglyceride clearance in young, healthy obese subjects and, second, to investigate if fasting triglycerides can predict delayed postprandial triglyceride clearance. Eighteen apparently healthy, obese subjects with no clinical signs of metabolic disturbances participated. Controls were age- and sex-matched, healthy, normal weight subjects. Subclinical markers of metabolic disturbances were assessed by measuring postprandial triglycerides in serum and in chylomicrons by oral fat tolerance test. Postprandial triglyceride clearance for 8 h was assessed indirectly as removal of the lipid from serum during the oral fat tolerance test. Insulin resistance was measured by the homeostasis model assessment of insulin resistance (HOMA-IR). Twelve (66%) of the apparently healthy obese individuals had insulin resistance measured by HOMA-IR. There was a delayed clearance of serum triglycerides and chylomicron triglycerides at 6 h when compared with the control group, while, at 8 h, the differences were only detected for the chylomicron triglyceride clearance. Triglyceride response was significantly greater in the obese subjects. Fasting triglycerides in upper normal level predicted a delayed postprandial triglyceride clearance and insulin resistance. In young, apparently healthy obese subjects early metabolic disturbances including insulin resistance and delayed postprandial triglyceride clearance can be detected. Fasting serum triglyceride in upper normal level predicted delayed postprandial triglyceride clearance and insulin resistance. © 2015 World Obesity.

  2. Dynamic characteristics analysis of deployable space structures considering joint clearance

    Science.gov (United States)

    Li, Tuanjie; Guo, Jian; Cao, Yuyan

    2011-04-01

    The clearance in joints influences the dynamic stability and the performance of deployable space structures (DSS). A virtual experimental modal analysis (VEMA) method is proposed to deal with the effects of joint clearance and link flexibility on the dynamic characteristics of the DSS in this paper. The focus is on the finite element modeling of the clearance joint, VEMA and the modal parameters identification of the DSS. The finite element models (FEM) of the clearance joint and the deployable structure are established in ANSYS. The transient dynamic analysis is conducted to provide the time history data of excitation and response for the VEMA. The fast Fourier transform (FFT) technique is used to transform the data from time domain to frequency domain. The frequency response function is calculated to identify the modal parameters of the deployable structure. Experimental verification is provided to indicate the VEMA method is both a cost and time efficient approach to obtain the dynamic characteristics of the DSS. Finally, we analyze the effects of clearance size and gravity on the dynamic characteristics of the DSS. The analysis results indicate that the joint clearance and gravity strongly influence the dynamic characteristics of the DSS.

  3. 32 CFR 644.522 - Clearance of military scrap.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of military scrap. 644.522 Section 644... Excess Land and Improvements § 644.522 Clearance of military scrap. Military scrap can contain or be... destruction, by using command, of all military scrap and scrap metal from lands suitable for cultivation or...

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast To learn more about how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist ...

  5. Lung clearance of inhaled particles after exposure to carbon black generated from a resuspension system

    International Nuclear Information System (INIS)

    Lee, P.S.; Gorski, R.A.; Hering, W.E.; Chan, T.L.

    1987-01-01

    A system to resuspend carbon black particles for providing submicron aerosols for inhalation exposure studies has been developed. The effect of continuous exposure to carbonaceous material (as a surrogate for the carbonaceous particles in diesel exhaust) on the pulmonary clearance of inhaled diesel tracer particles was studied in male Fischer 344 rats. Submicron carbon black particles with a mass median aerodynamic diameter (MMAD) of 0.22 micron and a size distribution similar to that of exhaust particles from a GM 5.7-liter diesel engine were successfully generated and administered to test animals at a nominal concentration of 6 mg/m3 for 20 hr/day, 7 days/week, for periods lasting 1 to 11 weeks. Immediately after the carbon black exposure, test animals were administered 14 C-tagged diesel particles for 45 min in a nose-only chamber. The pulmonary retention of inhaled radioactive tracer particles was determined at preselected time intervals. Based upon the data collected up to 1 year postexposure, prolonged exposure to carbon black particles exhibits a similar inhibitory effect on pulmonary clearance as does prolonged exposure to diesel exhaust with a comparable particulate dose. This observation indicates that the excessive accumulation of carbonaceous material may be the predominant factor affecting lung clearance

  6. Wide Area Recovery and Resiliency Program (WARRP) Interim Clearance Strategy for Environments Contaminated with Hazardous Chemicals

    Science.gov (United States)

    2012-07-01

    imperative that the community address the range of values, and have agreement, before a disaster strikes. Pre-event clearance level concurrence is...on the cleanup of specific sites: those containing only cesium-137 (Goiania) and those containing 137Cs and other radionuclides ( Chernobyl ...targets and consider initiatives to enhance the quality of life of the residents of the contaminated areas. Recovery experience from the Chernobyl

  7. Clearance level and industrial waste management

    International Nuclear Information System (INIS)

    Asano, Toichi

    1999-01-01

    Defining the clearance level enables the radioactive waste with lower radioactivity than a certain level to be the general industrial waste and therefore consideration for public acceptance is essential. For this, it is necessary to understand laws concerning not only atomic power and radioactivity but also disposal and cleaning of general waste. It is also necessary that the waste below the clearance level should be as much as possible handled in the modern common concept of recycling of resources. In 1996, the weight of industrial waste was about 400 million tons, of which 40% was disposed by burning and dehydration, 39% was re-used and 21% was subjected to the final disposal like reclamation. Reduction, re-use and recycling of the generated waste are required for making the society with recycling of resources. Scrap concrete materials below the clearance level of 0.6 million tons are estimated to be generated by dismantling the light water reactor of 1 million kW output and profitable technology for recycling the scrap is under investigation. (K.H.)

  8. Factors Associated with Spontaneous Clearance of Hepatitis C Virus in Chinese Population

    Directory of Open Access Journals (Sweden)

    Fei Kong

    2014-01-01

    Full Text Available Hepatitis C virus (HCV infections spontaneously clear in approximately 15–45% of infected individuals. Factors which influence spontaneous HCV clearance remain to be identified. The purpose of the present study was to identify variables associated with spontaneous HCV clearance in a referred population of Chinese patients. The prevalence of host, viral, and environmental factors known to influence the outcome of HCV infections was compared in 92 HCV spontaneous clearance subjects and 318 HCV persistent infection subjects. Univariate and multivariate analyses were performed to identify those factors associated with spontaneous HCV clearance. In univariate analysis, female gender, a history of icteric hepatitis, serologic evidence of concurrent HBV infection, and rs12979860 CC genotype were positively associated with spontaneous HCV clearance, while alcohol consumption was negatively associated with clearance. In multivariate analysis, female gender, a history of icteric hepatitis, concurrent HBV infection, and rs12979860 CC genotype remained independent variables associated with spontaneous HCV clearance. Spontaneous HCV clearance is more likely to occur in females, subjects with a history of icteric hepatitis, HBV coinfections, and those with the rs12979860 CC genotype.

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage ...

  10. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  11. Whole body and regional clearances of noradrenaline and adrenaline in man

    DEFF Research Database (Denmark)

    Christensen, N J; Galbo, H; Gjerris, Anne Cathrine Roslev

    1984-01-01

    we found no correlation between clearance values based on venous and arterial sampling. In other experiments we measured the influence of physical exercise in young healthy subjects on the clearance rate of plasma adrenaline (A). The clearance of A, which at rest averaged 1.9 l/min tended to increase...

  12. Using Terrestrial Laser Scanners to Calculate and Map Vertical Bridge Clearance

    Science.gov (United States)

    Zhang, C.; Arditi, D.; Chen, Z.

    2013-08-01

    The vertical clearance of a bridge over a highway is important in preventing oversized vehicles from hitting the bridge. The vertical clearance of a bridge is traditionally measured by using surveying equipment such as leveling rods and total stations. Typically, measurements are taken at multiple locations in order to determine the minimum vertical clearance under the bridge. This process is time and labor consuming. Also, these measurements may not be accurate because of the traffic, the uneven surface, and the reading error caused by the surveyor. Additionally, when one is faced with a multitude of reports especially in large projects with multiple ramps and bridges, it is not easy and it often takes a long time to find the bridge under study. This research provides a highly accurate measurement of the vertical bridge clearance by using terrestrial laser scanners. The clearance can be measured in the office by processing the collected point cloud data. The minimum vertical clearance is easily identified and the measurement is visualized and geo-referenced. An approach to reduce data noise caused by traffic is also introduced in this study. In addition, to help reduce the confusion of finding the bridge under study and to facilitate access to the clearance data, the clearance measurements are geo-referenced to an online mapping system. This system allows access to the final deliverable very easily through a single web portal. Finally, Illinois Department of Transportation's Circle Interchange is used to demonstrate this new method.

  13. Targeted therapy using nanotechnology: focus on cancer.

    Science.gov (United States)

    Sanna, Vanna; Pala, Nicolino; Sechi, Mario

    2014-01-01

    Recent advances in nanotechnology and biotechnology have contributed to the development of engineered nanoscale materials as innovative prototypes to be used for biomedical applications and optimized therapy. Due to their unique features, including a large surface area, structural properties, and a long circulation time in blood compared with small molecules, a plethora of nanomaterials has been developed, with the potential to revolutionize the diagnosis and treatment of several diseases, in particular by improving the sensitivity and recognition ability of imaging contrast agents and by selectively directing bioactive agents to biological targets. Focusing on cancer, promising nanoprototypes have been designed to overcome the lack of specificity of conventional chemotherapeutic agents, as well as for early detection of precancerous and malignant lesions. However, several obstacles, including difficulty in achieving the optimal combination of physicochemical parameters for tumor targeting, evading particle clearance mechanisms, and controlling drug release, prevent the translation of nanomedicines into therapy. In spite of this, recent efforts have been focused on developing functionalized nanoparticles for delivery of therapeutic agents to specific molecular targets overexpressed on different cancer cells. In particular, the combination of targeted and controlled-release polymer nanotechnologies has resulted in a new programmable nanotherapeutic formulation of docetaxel, namely BIND-014, which recently entered Phase II clinical testing for patients with solid tumors. BIND-014 has been developed to overcome the limitations facing delivery of nanoparticles to many neoplasms, and represents a validated example of targeted nanosystems with the optimal biophysicochemical properties needed for successful tumor eradication.

  14. A natural human monoclonal antibody targeting Staphylococcus Protein A protects against Staphylococcus aureus bacteremia

    Science.gov (United States)

    Varshney, Avanish K.; Sunley, Kevin M.; Bowling, Rodney A.; Kwan, Tzu-Yu; Mays, Heather R.; Rambhadran, Anu; Zhang, Yanfeng; Martin, Rebecca L.; Cavalier, Michael C.; Simard, John

    2018-01-01

    Staphylococcus aureus can cause devastating and life-threatening infections. With the increase in multidrug resistant strains, novel therapies are needed. Limited success with active and passive immunization strategies have been attributed to S. aureus immune evasion. Here, we report on a monoclonal antibody, 514G3, that circumvents a key S. aureus evasion mechanism by targeting the cell wall moiety Protein A (SpA). SpA tightly binds most subclasses of immunoglobulins via their Fc region, neutralizing effector function. The organism can thus shield itself with a protective coat of serum antibodies and render humoral immunity ineffective. The present antibody reactivity was derived from an individual with natural anti-SpA antibody titers. The monoclonal antibody is of an IgG3 subclass, which differs critically from other immunoglobulin subclasses since its Fc is not bound by SpA. Moreover, it targets a unique epitope on SpA that allows it to bind in the presence of serum antibodies. Consequently, the antibody opsonizes S. aureus and maintains effector function to enable natural immune mediated clearance. The data presented here provide evidence that 514G3 antibody is able to successfully rescue mice from S. aureus mediated bacteremia. PMID:29364906

  15. Further training in the fields of radiological characterisation and clearance; Weiterbildung auf den Gebieten radiologische Charakterisierung und Freigabe

    Energy Technology Data Exchange (ETDEWEB)

    Bothe, M. [VKTA - Strahlenschutz, Analytik und Entsorgung Rossendorf e.V., Dresden (Germany); Feinhals, J. [DMT GmbH und Co.KG, Hamburg (Germany); Neukaeter, E. [BKW Energie AG, Muehleberg (Switzerland). KKW Muehleberg

    2016-07-01

    Radiological characterisation and clearance require specific knowledge and skills. Targeted further training of the staff is one possibility to get this knowledge and skills. A modular concept was established, which allows adaption to specific requests of the institution and state of knowledge and skills of participants. The modules have following focuses: ''radiological characterisation and clearance'', ''sampling'' and ''measurement and sampling plans'' and consist half-and-half of lectures and group works. In group works participants apply new knowledge to examples of the installation or simulated scenarios and afterwards they present and discuss the results. This concept was carried out for different institutions and is planned for some more.

  16. Respiratory clearance of aerosolized radioactive solutes of varying molecular weight

    International Nuclear Information System (INIS)

    Huchon, G.J.; Montgomery, A.B.; Lipavsky, A.; Hoeffel, J.M.; Murray, J.F.

    1987-01-01

    To determine the influence of varying molecular weight (mol wt) on respiratory clearance of aerosolized solutes, we studied eight radiopharmaceuticals, each administered to four dogs: sodium /sup 99m/Tc pertechnetate (TcO4), /sup 99m/Tc glucoheptonate ([/sup 99m/Tc]GH), 51Cr-ethylenedinitrotetraacetate ([51Cr]EDTA), /sup 99m/Tc diethylenetriaminepentaacetate ([99mTc] DTPA), 111 In diethylenetriaminepentaacetate ([ 111 In]DTPA), 67 Ga desferoxaminemesylate ([ 67 Ga]DFOM), /sup 99m/Tc dextran ([/sup 99m/Tc]DX) and 111 In transferrin ([ 111 In]TF). After aerosolization (0.8 m MMD, 2.4 GSD), clearance was determined for 30 min and then corrected by intravenous injection for nonairspace radioactivity. In-TF clearance (0.11 +/- 0.10%/min) was lower than TcO4 (6.32 +/- 0.62%/min), [/sup 99m/Tc]GH (1.50 +/- 0.37%/min), [ 51 Cr]EDTA (2.38 +/- 1.02%/min), [/sup 99m/Tc]DTPA (3.51 +/- 0.40%/min), [ 111 In]DTPA (2.35 +/- 0.42%/min), [ 67 Ga] DFOM (1.99 +/- 0.49%/min) and [/sup 99m/Tc]DX (1.81 +/- 0.75%/min) clearances (p less than 0.001). TcO4 clearance was higher than others (p less than 0.001). Technetium binding to DX was unsatisfactory; aerosolization caused unbinding from DTPA. We conclude that respiratory clearance of large mol wt solutes within 30 min is negligible and, that clearance of molecules between 347-5099 daltons differs greatly, suggesting that binding and/or intrapulmonary retention affect transfer

  17. Comparison of German and international clearance regulations - chances and limits for harmonization

    International Nuclear Information System (INIS)

    Thierfeldt, S.; Schartmann, F.

    2005-01-01

    The regulations on clearance in the German nuclear regulatory framework (especially sect. 29 and Annexes III and IV of the Radiation Protection Ordinance) are comprehensive and well founded. Germany has developed some of its clearance levels in advance of recommendations issued by the EC. Therefore, there are differences between the German and international clearance regulations. That has been investigated by a working group on clearance of the German Commission on Radiological Protection (SSK) which has performed an analysis of differences and their reasons for clearance levels in Germany and other countries (UK, The Netherlands, Sweden, USA and others). Differences can mainly be explained by country specific approaches in scenarios. Differences especially for the most relevant nuclides are not significant from a radiological point of view. The level of radiological protection (trivial dose range, a few 10 μSv/a) is guaranteed in all countries. The international discussion on the international harmonisation of clearance levels (mainly within the scope of the OECD/NEA and IAEA) can be enlightened on the basis of these results. This discussion concentrates on the question how far a harmonisation of clearance level values is actually necessary and possible. The IAEA Safety Guide RS-G-1.7 'Application of the concepts of exclusion, exemption and clearance' is of particular importance, because it proposes a set of values which might in the long-term take the role of international unconditional clearance levels. International harmonisation is only relevant for unconditional clearance of those materials, which are traded in large quantities among countries, in particular metal scrap. Harmonisation of the values to the same order of magnitude is sufficient. (orig.)

  18. Discrepancy between circadian rhythms of inulin and creatinine clearance

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; Krediet, R. T.; Arisz, L.

    1992-01-01

    To elucidate the disparity between circadian rhythmicity of inulin and creatinine clearance, we simultaneously measured inulin and creatinine clearances every 3 hours during 1 day in 14 normal subjects and in 8 patients with nephrotic syndrome. All patients and normal subjects had a circadian rhythm

  19. Lung clearance of 99m Tc- DTPA in systemic lupus erythematous

    International Nuclear Information System (INIS)

    Dalcin, P.T.R; Barreto, S.S.M.; Xavier, R.M.; Brenol, J.C.T.; Cunha, R.D.; Marroni, B.J.

    2002-01-01

    The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99 mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99 mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnoea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99 m Tc-DTPA is increased in SLE patients with active disease. (author)

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... cystic fibrosis. CF CARE CENTER finder We provide funding for and accredit more than 120 care centers ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  1. 48 CFR 32.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  2. 48 CFR 832.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  3. Compression deformation behaviors of sheet metals at various clearances and side forces

    Directory of Open Access Journals (Sweden)

    Zhan Mei

    2015-01-01

    Full Text Available Modeling sheet metal forming operations requires understanding of plastic behaviors of sheet metals along non-proportional strain paths. The plastic behavior under reversed uniaxial loading is of particular interest because of its simplicity of interpretation and its application to material elements drawn over a die radius and underwent repeated bending. However, the attainable strain is limited by failures, such as buckling and in-plane deformation, dependent on clearances and side forces. In this study, a finite element (FE model was established for the compression process of sheet specimens, to probe the deformation behavior. The results show that: With the decrease of the clearance from a very large value to a very small value, four defects modes, including plastic t-buckling, micro-bending, w-buckling, and in-plane compression deformation will occur. With the increase of the side force from a very small value to a very large value, plastic t-buckling, w-buckling, uniform deformation, and in-plane compression will occur. The difference in deformation behaviors under these two parameters indicates that the successful compression process without failures for sheet specimens only can be carried out under a reasonable side force.

  4. Treatment of Moderate Sized Renal Pelvis Calculi: Stone Clearance Time Comparison of Extracorporeal Shock Wave Lithotripsy and Retrograde Intrarenal Surgery.

    Science.gov (United States)

    Ercil, Hakan; Alma, Ergun; Bas, Okan; Sener, Nevzat Can; Vuruskan, Ediz; Kuyucu, Faruk; Unal, Umut; Gören, Mehmet Resit; Evliyaoglu, Yalcin

    2016-03-05

    To compare the stone clearance times in patients undergoing extracorporeal shock wave lithotripsy (SWL) or retrograde intrarenal surgery (RIRS) for single radiopaque renal pelvis stones 10-20 mm in size. The results of this study may guide urologists and patients and aid in selecting the optimal preoperative treatment. Between January 2013 and February 2015, we conducted a retrospective study and collected data from 333 patients treated with SWL (n = 172) or RIRS (n = 161). We included successfully treated patients with a single radiopaque renal pelvis stone 10-20 mm in size to calculate stone clearance times. The average stone size for the SWL group was 14.62 ± 2.58 mm and 14.91 ± 2.92 mm for the RIRS group. The mean Hounsfield unit (HU) of the patients was 585.40 ± 158.39 HU in the SWL group and 567.74 ± 186.85 HU in the RIRS group. Following full fragmentation, the mean stone clearance time was 26.55 ± 9.71 days in the SWL group and 11.59 ± 7.01 days in the RIRS group (P < .001). One of the most overlooked parameters in urinary stone treatments is stone clearance. We believe this study will shed light for those who aim to conduct larger randomized prospective studies. .

  5. Secretion clearance strategies in Australian and New Zealand Intensive Care Units.

    Science.gov (United States)

    Ntoumenopoulos, George; Hammond, Naomi; Watts, Nicola R; Thompson, Kelly; Hanlon, Gabrielle; Paratz, Jennifer D; Thomas, Peter

    2017-06-26

    To describe the processes of care for secretion clearance in adult, intubated and mechanically ventilated patients in Australian and New Zealand Intensive Care Units (ICUs). A prospective, cross-sectional study was conducted through the Australian and New Zealand Intensive Care Society Clinical Trials Group (ANZICS CTG) Point Prevalence Program. Forty-seven ICUs collected data from 230 patients intubated and ventilated on the study day. Secretion clearance techniques beyond standard suctioning were used in 84/230 (37%) of patients during the study period. Chest wall vibration 34/84 (40%), manual lung hyperinflation 24/84 (29%), chest wall percussion 20/84 (24%), postural drainage/patient positioning 17/84 (20%) and other techniques including mobilisation 15/84 (18%), were the most common secretion clearance techniques employed. On average (SD), patients received airway suctioning 8.8 (5.0) times during the 24-h study period. Mucus plugging events were infrequent (2.7%). The additional secretion clearance techniques were provided by physiotherapy staff in 24/47 (51%) ICUs and by both nursing and physiotherapy staff in the remaining 23/47 (49%) ICUs. One-third of intubated and ventilated patients received additional secretion clearance techniques. Mucus plugging events were infrequent with these additional secretion clearance approaches. Prospective studies must examine additional secretion clearance practices, prevalence of mucus plugging episodes and impact on patient outcomes. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  6. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  7. A Study to Determine Clearance Levels of Radioactive Wastes in Kenya

    Energy Technology Data Exchange (ETDEWEB)

    Mukakaa, Zaphania O. [KAIST, Daejeon (Korea, Republic of); Kim, Sung Il [KINS, Daejeon (Korea, Republic of)

    2015-10-15

    Due to lack of a radioactive waste disposal facility in Kenya, radioactive wastes are stored in a bonded warehouse until such a time when their activity is low and they meet the criterion for clearance. The International Atomic Energy Agency (IAEA) has established activity concentrations of radionuclides to act as a universal guideline or standard for clearance in member countries. Radioactive wastes whose activity would yield a trivial risk to the people and environment, i.e. with an annual dose below 10 µSv are usually cleared from regulatory control with no further regulatory control mechanisms being taken. The Radiation Protection Board currently depends on the IAEA's generic clearance level activity concentrations for purposes of clearing the radiation wastes within its inventory. This study aims to determine activity concentrations of radionuclides in the Kenyan inventory that correspond to the clearance level dose of 10 µSv/a as set by the IAEA. The RESidual RADioactivity (RESRAD) computer code, an important tool developed in 1989 to aid in evaluation of sites with radioactive contamination, will aid in modeling these clearance level values using a pathways analysis method and available site-specific data from Kenya. Afterwards, the obtained clearance level values will be compared with the IAEA's generic clearance level values of the corresponding radionuclides. The results modeled using the RESRAD code are conservative. For most of the radionuclides in the Kenyan inventory, the values do correspond with the IAEA standard generic clearance level values, albeit with minor differences. For most of the radionuclides, the difference is within the acceptable uncertainty limit. For these low probability events the effective dose resulting from them should not exceed 1 mSv per year. Thus, consideration was given to doses to the skin and an equivalent dose to the skin of 50 mSv per year was duly used in estimating the clearance level activities. The

  8. Factors contributing to delay in parasite clearance in uncomplicated falciparum malaria in children

    Directory of Open Access Journals (Sweden)

    Sijuade Abayomi

    2010-02-01

    Full Text Available Abstract Background Drug resistance in Plasmodium falciparum is common in many endemic and other settings but there is no clear recommendation on when to change therapy when there is delay in parasite clearance after initiation of therapy in African children. Methods The factors contributing to delay in parasite clearance, defined as a clearance time > 2 d, in falciparum malaria were characterized in 2,752 prospectively studied children treated with anti-malarial drugs between 1996 and 2008. Results 1,237 of 2,752 children (45% had delay in parasite clearance. Overall 211 children (17% with delay in clearance subsequently failed therapy and they constituted 72% of those who had drug failure, i.e., 211 of 291 children. The following were independent risk factors for delay in parasite clearance at enrolment: age less than or equal to 2 years (Adjusted odds ratio [AOR] = 2.13, 95% confidence interval [CI]1.44-3.15, P 50,000/ul (AOR = 2.21, 95% CI = 1.77-2.75, P 20000/μl a day after treatment began, were independent risk factors for delay in clearance. Non-artemisinin monotherapies were associated with delay in clearance and treatment failures, and in those treated with chloroquine or amodiaquine, with pfmdr 1/pfcrt mutants. Delay in clearance significantly increased gametocyte carriage (P Conclusion Delay in parasite clearance is multifactorial, is related to drug resistance and treatment failure in uncomplicated malaria and has implications for malaria control efforts in sub-Saharan Africa.

  9. Effect of glucose-insulin-potassium infusion on thallium myocardial clearance

    International Nuclear Information System (INIS)

    Wilson, R.A.; Okada, R.D.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Factors influencing the rate of 201 Tl clearance from the myocardium have not been clearly defined. This study determined the effect of an intravenous infusion of glucose-insulin-potassium (GIK) on the net 201 Tl clearance rates from myocardium with and without initial 201 Tl loading. Anesthetized open-chest dogs underwent 5 min of left anterior descending coronary artery occlusion and intravenous 201 Tl was injected and the occlusion released 5 min later. Thirty minutes after 201 Tl injection, 30 ml of either GIK (nine dogs) or saline (five dogs) was infused intravenously. The clearance rates of 201 Tl from the anterior wall (without initial 201 Tl loading) and from the posterior wall (with initial 201 Tl loading) were monitored with miniaturized cadmium telluride detectors placed on the myocardium. Calculation of net myocardial clearance rates was performed by linear regression analysis from serial 1 min counts. Compared with saline infusion, GIK increased the net clearance of 201 Tl from both myocardial regions with and without initial loading. The most marked change induced by GIK infusion was in the myocardial region without initial 201 Tl loading; a net increase in 201 Tl activity (72 +/- 42 cpm/30 min) was converted into a net loss (-594 +/- 228 cpm/30 min). There was no significant change in 201 Tl clearance after the saline infusion. Heart rate, aortic and left atrial pressure, sonomicrometer-measured transmural myocardial wall thickness, microsphere-determined myocardial blood flow, and blood glucose and potassium concentrations did not change significantly during GIK or saline infusions. Thus, GIK infusion appears to increase net 201 Tl clearance from myocardial zones with and without initial 201 Tl loading

  10. Comparison of measurements of plasma clearance of Mebrofenine and of indocyanine green

    International Nuclear Information System (INIS)

    Maurel, G.; Coutris, G.; Vaubourdolle, M.; Attal, P.; Patureau, R.; Tabsoba, Th.; Mensch, B.; Askienazy, Pr.S.

    1997-01-01

    The importance of clearance measurements in evaluating renal or hepatic function needs not further demonstration. The isotopic methods were proved in renal exploration but their utilization in exploration of hepato-biliary function needs to be evaluated. In this work we have compared the measurement of plasma clearance by Mebrofenine, a radiopharmaceutical of specifically hepatic elimination, with the reference method, the clearance of indocyanine green. On the basis of scintigraphic data from 23 patients who benefited by a hepato-biliary exploration by Mebrofenine- 99m Tc for pre-surgery account and surveillance, we have determined the plasma clearance of this radiopharmaceutical. The method makes use of the curve of normalized cardiac activity by a blood sampling, taken 60 minutes after injection. The measurement of the clearance of indocyanine green was effected within a delay inferior to 1 month from the moment of biliary scintigraphy. The average clearance of Mebrofenine- 99m Tc is of 553 ml/min for 1.73 m 2 of corporal surface (typical interval is 374 ml/min), the value of indocyanine green is of 450 ml/min (typical interval is 229 ml/min). The two measurements of clearance are correlated (p = 0.05). In conclusion, the measurement of clearance by Mebrofenine- 99m appears to be adapted to the evaluation of hepato-biliary function

  11. 48 CFR 1432.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  12. Determining vancomycin clearance in an overweight and obese population.

    Science.gov (United States)

    Leong, Julie V B; Boro, Maureen S; Winter, Michaele

    2011-04-01

    Two methods of calculating vancomycin clearance were compared to determine the best body weight measure to use when dosing vancomycin for overweight and obese patients. Hospitalized veterans weighing more than 120% of their ideal body weight (IBW) with serum vancomycin concentrations (SVCs) drawn between January 1, 2003, and June 30, 2005, were eligible for study inclusion. Exclusion criteria included weight of more than 300% the IBW, unstable renal function, dialysis, uncertain vancomycin dosing or sampling times, and distribution-phase sampling. Data from January 1 through December 31, 2003 (phase 1) determined the best-fit weight for vancomycin clearance for the Leonard and Boro method. The bias and precision of the modified Leonard and Boro method using the best-fit weight for vancomycin clearance were then compared with those of the Rushing and Ambrose method for predicting SVCs from January 1, 2004, through June 30, 2005 (phase 2). Forty-eight patients were included in phase 1, with 67 SVCs for analysis. During phase 1, adjusted body weight (ABW), using the Leonard and Boro method, was superior in predicting vancomycin clearance and the resultant SVCs. A total of 96 patients were included in phase 2 of the study, with 160 SVCs for analysis. The modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting vancomycin clearance. Use of ABW proved to be superior compared with total body weight when estimating vancomycin clearance in overweight and obese patients. While there was no difference in bias between methods, the modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting SVCs when dosing vancomycin for obese patients.

  13. Tip clearance effect on through-flow and performance of a centrifugal compressor

    International Nuclear Information System (INIS)

    Eum, Hark Jin; Kang, Young Seok; Kang, Shin Hyoung

    2004-01-01

    Numerical simulations have been performed to investigate tip clearance effect on through-flow and performance of a centrifugal compressor which has the same configuration of impeller with six different tip clearances. Secondary flow and loss distribution have been surveyed to understand the flow mechanism due to the tip clearance. Tip leakage flow strongly interacts with mainstream flow and considerably changes the secondary flow and the loss distribution inside the impeller passage. A method has been described to quantitatively estimate the tip clearance effect on the performance drop and the efficiency drop. The tip clearance has caused specific work reduction and additional entropy generation. The former, which is called inviscid loss, is independent of any internal loss and the latter, which is called viscous loss, is dependent on every loss in the flow passage. Two components equally affected the performance drop as the tip clearances were small, while the efficiency drop was influenced by the viscous component alone. The additional entropy generation was modeled with all the kinetic energy of the tip leakage flow. Therefore, the present paper can provide how to quantitatively estimate the tip clearance effect on the performance and efficiency

  14. Tear clearance implications for ocular surface health.

    Science.gov (United States)

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  15. Clearance of Tc-99m DTPA in hemodialysis and peritoneal dialysis: concise communication

    International Nuclear Information System (INIS)

    Wainer, E.; Boner, G.; Lubin, E.; Rosenfeld, J.B.

    1981-01-01

    The clearance of Tc-99m DTPA was studied in 14 patients undergoing hemodialysis (HD) or peritoneal dialysis (PD). Mean Tc-99m DTPA clearance during HD was 37.8% +/- 10.1 of creatinine clearance. Mean Tc-99m DTPA clearance in PD was 65.1% +/- 10.3 of creatinine clearance. Tc-99m DTPA, with a larger molecular weight than that of creatinine, is cleared relatively better during PD than during HD. Thus Tc-99m DTPA may be used in the assessment of the effectiveness of different dialytic treatments for substances of similar molecular weight. In addition, our study shows that clearance of DTPA both in HD and PD is sufficiently high to allow the removal of this chelating agent in patients with renal failure

  16. Effect of isolated hepatic ischemia on organic anion clearance and oxidative metabolism.

    Science.gov (United States)

    Minard, G; Bynoe, R; Wood, G C; Fabian, T C; Croce, M; Kudsk, K A

    1992-04-01

    Hepatic failure is frequently seen following severe hemorrhagic shock, sepsis, and trauma. Clearance of various drugs has been used to evaluate hepatocellular dysfunction, including indocyanine green (ICG), an organic anionic dye that is transported similarly to bilirubin, and antipyrine (AP), a marker of oxidative phosphorylation. Previous investigators have noted a decrease in ICG excretion following systemic hemorrhage. The effect of isolated hepatic ischemia on the clearances of ICG and AP was studied in 16 pigs after 90 minutes of vascular occlusion to the liver. Antipyrine clearance decreased almost 50% from baseline values at 24 and 72 hours after the ischemia procedure, indicating a significant depression in the cytochrome P-450 system. On the other hand, ICG clearance did not change significantly. In conclusion, ICG clearance is not depressed after isolated hepatic ischemia in pigs. Changes in organic anion clearance after systemic hemorrhage may be because of release of toxic products from ischemic peripheral tissue.

  17. Clearance of 99mTc-DTPA and experimentally increased alveolar surfactant content

    International Nuclear Information System (INIS)

    Bos, J.A.H.; Wollmer, P.; Bakker, W.; Hannappel, E.; Lachmann, B.

    1992-01-01

    The authors measured clearance of 99m Tc-labeled diethylenetriamine pentaacetic acid ( 99m Tc-DTPA) in rabbits with experimentally increased alveolar surfactant content. In one group of animals, surfactant production was increased by treatment with ambroxol, and another group of animals was treated with tracheal instillation of natural surfactant. A group of untreated control animals and animals treated with instillation of saline were also studied. Clearance was measured during standard conditions of mechanical ventilation and during ventilation with large tidal volumes. In ambroxol- and surfactant-treated groups, clearance rate was reduced compared with untreated control animals. In contrast, clearance rate increased after saline instillation. The differences were observed at both modes of ventilation. The findings indicate that the pulmonary surfactant system is a rate-limiting factor for the clearance of 99m Tc-DTPA and that the volume dependence of clearance is not explained by stretching of the alveolar wall only. 28 refs., 2 figs., 1 tab

  18. Novel lanthanide-labeled metal oxide nanoparticles improve the measurement of in vivo clearance and translocation

    Directory of Open Access Journals (Sweden)

    Abid Aamir D

    2013-01-01

    Full Text Available Abstract The deposition, clearance and translocation of europium-doped gadolinium oxide nanoparticles in a mouse lung were investigated experimentally. Nanoparticles were synthesized by spray flame pyrolysis. The particle size, crystallinity and surface properties were characterized. Following instillation, the concentrations of particles in organs were determined with inductively coupled plasma mass spectrometry. The protein corona coating the nanoparticles was found to be similar to the coating on more environmentally relevant nanoparticles such as iron oxide. Measurements of the solubility of the nanoparticles in surrogates of biological fluids indicated very little propensity for dissolution, and the elemental ratio of particle constituents did not change, adding further support to the contention that intact nanoparticles were measured. The particles were intratracheally instilled into the mouse lung. After 24 hours, the target organs were harvested, acid digested and the nanoparticle mass in each organ was measured by inductively coupled plasma mass spectrometry (ICP-MS. The nanoparticles were detected in all the studied organs at low ppb levels; 59% of the particles remained in the lung. A significant amount of particles was also detected in the feces, suggesting fast clearance mechanisms. The nanoparticle system used in this work is highly suitable for quantitatively determining deposition, transport and clearance of nanoparticles from the lung, providing a quantified measure of delivered dose.

  19. Domiciliary humidification improves lung mucociliary clearance in patients with bronchiectasis.

    Science.gov (United States)

    Hasani, A; Chapman, T H; McCool, D; Smith, R E; Dilworth, J P; Agnew, J E

    2008-01-01

    Inspired air humidification has been reported to show some benefit in bronchiectatic patients. We have investigated the possibility that one effect might be to enhance mucociliary clearance. Such enhancement might, if it occurs, help to lessen the risks of recurrent infective episodes. Using a radioaerosol technique, we measured lung mucociliary clearance before and after 7 days of domiciliary humidification. Patients inhaled high flow saturated air at 37 degrees C via a patient-operated humidification nasal inhalation system for 3 h per day. We assessed tracheobronchial mucociliary clearance from the retention of (99m)Tc-labelled polystyrene tracer particles monitored for 6 h, with a follow-up 24-h reading. Ten out of 14 initially recruited patients (age 37-75 years; seven females) completed the study (two withdrew after their initial screening and two prior to the initial clearance test). Seven patients studied were non-smokers; three were ex-smokers (1-9 pack-years). Initial tracer radioaerosol distribution was closely similar between pre- and post-treatment. Following humidification, lung mucociliary clearance significantly improved, the area under the tracheobronchial retention curve decreased from 319 +/- 50 to 271 +/- 46%h (p humidification treatment improved lung mucociliary clearance in our bronchiectatic patients. Given this finding plus increasing laboratory and clinical interest in humidification mechanisms and effects, we believe further clinical trials of humidification therapy are desirable, coupled with analysis of humidification effects on mucus properties and transport.

  20. 48 CFR 245.7101-4 - DD Form 1640, Request for Plant Clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false DD Form 1640, Request for Plant Clearance. 245.7101-4 Section 245.7101-4 Federal Acquisition Regulations System DEFENSE... Forms 245.7101-4 DD Form 1640, Request for Plant Clearance. Use to request plant clearance assistance or...

  1. Impairment of nasal mucociliary clearance in woodworkers in the furniture industry

    Science.gov (United States)

    Black, A.; Evans, J. C.; Hadfield, Esme H.; Macbeth, R. G.; Morgan, A.; Walsh, M.

    1974-01-01

    Black, A., Evans, J. C., Hadfield, Esme H., Macbeth, R. G., Morgan, A., and Walsh, M. (1974).British Journal of Industrial Medicine,31, 10-17. Impairment of nasal mucociliary clearance in woodworkers in the furniture industry. Measurements of mucociliary clearance from the anterior end of the middle turbinate were made using technetium-99m-labelled particles in nine woodworkers from the furniture industry and in 12 controls, none of whom had been occupationally exposed to wood dust. Clearance rates in the controls ranged from 1·9 to 18·5 mm min-1 with a mean of 6·8. These values are in good agreement with measurements reported elsewhere for normal subjects. Only one of the woodworkers had a clearance rate which fell within the normal range and he had been occupationally exposed for the shortest period (6 years). In four woodworkers clearance was very slow (furniture industry for more than 10 years. PMID:4821406

  2. Enzyme-inducing anticonvulsants increase plasma clearance of dexmedetomidine: a pharmacokinetic and pharmacodynamic study.

    Science.gov (United States)

    Flexman, Alana M; Wong, Harvey; Riggs, K Wayne; Shih, Tina; Garcia, Paul A; Vacas, Susana; Talke, Pekka O

    2014-05-01

    Dexmedetomidine is useful during mapping of epileptic foci as it facilitates electrocorticography unlike most other anesthetic agents. Patients with seizure disorders taking enzyme-inducing anticonvulsants appear to be resistant to its sedative effects. The objective of the study was to compare the pharmacokinetic and pharmacodynamic profile of dexmedetomidine in healthy volunteers with volunteers with seizure disorders receiving enzyme-inducing anticonvulsant medications. Dexmedetomidine was administered using a step-wise, computer-controlled infusion to healthy volunteers (n = 8) and volunteers with seizure disorders (n = 8) taking phenytoin or carbamazapine. Sedation and dexmedetomidine plasma levels were assessed at baseline, during the infusion steps, and after discontinuation of the infusion. Sedation was assessed by using the Observer's Assessment of Alertness/Sedation Scale, Ramsay Sedation Scale, and Visual Analog Scale and processed electroencephalography (entropy) monitoring. Pharmacokinetic analysis was performed on both groups, and differences between groups were determined using the standard two-stage approach. A two-compartment model was fit to dexmedetomidine concentration-time data. Dexmedetomidine plasma clearance was 43% higher in the seizure group compared with the control group (42.7 vs. 29.9 l/h; P = 0.007). In contrast, distributional clearance and the volume of distribution of the central and peripheral compartments were similar between the groups. No difference in sedation was detected between the two groups during a controlled range of target plasma concentrations. This study demonstrates that subjects with seizure disorders taking enzyme-inducing anticonvulsant medications have an increased plasma clearance of dexmedetomidine as compared with healthy control subjects.

  3. Renal clearance of 99mTc-methylene-diphosphonate in human beings

    International Nuclear Information System (INIS)

    Vattimo, A.

    1987-01-01

    The renal clearance of 99m Tc-MDP was measured in 13 patients who had bone scans and compared with the renal clearance of 51 Cr-EDTA. No difference was found between the renal clearance of the two tracers, showing a close correlation (r = 0.98). These data suggest that the 99m Tc-MDP is excreted by the kidneys by glomerular filtration without tubular secretion. (orig.) [de

  4. Replication and clearance of respiratory syncytial virus - Apoptosis is an important pathway of virus clearance after experimental infection with bovine respiratory syncytial virus

    DEFF Research Database (Denmark)

    Viuff, B.; Tjørnehøj, Kirsten; Larsen, Lars Erik

    2002-01-01

    and clearance in a natural target animal. Replication of BRSV was demonstrated in the luminal part of the respiratory epithelial cells and replication in the upper respiratory tract preceded the replication in the lower respiratory tract. Virus excreted to the lumen of the respiratory tract was cleared...... and the infections with human respiratory syncytial. virus and BRSV have similar clinical, pathological, and epidemiological characteristics. In this study we used experimental BRSV infection in calves as a model of respiratory syncytial virus infection to demonstrate important aspects of viral replication......Human respiratory syncytial virus is an important cause of severe respiratory disease in young children, the elderly, and in immunocompromised adults. Similarly, bovine respiratory syncytial virus (BRSV) is causing severe, sometimes fatal, respiratory disease in calves. Both viruses are pneumovirus...

  5. Acute exposure to acid fog. Effects on mucociliary clearance

    International Nuclear Information System (INIS)

    Laube, B.L.; Bowes, S.M. III; Links, J.M.; Thomas, K.K.; Frank, R.

    1993-01-01

    Submicrometric sulfuric acid (H2SO4) aerosol can affect mucociliary clearance without eliciting irritative symptoms or changes in pulmonary function. The effect of larger fog droplets containing H2SO4 on mucociliary clearance is unknown. We quantified mucociliary clearance from the trachea (n = 4) and small airways (n = 7) of young healthy male adults after an acute exposure to H2SO4 fog (MMAD = 10.3 microns; pH = 2.0; liquid water content = 481 +/- 65 mg/m3; osmolarity = 30 mOsm). Acid fog (AF) or saline fog (SF) (10.9 microns; 492 +/- 116 mg/m3; 30 mOsm) was administered for 40 min of unencumbered breathing (no mouth-piece) at rest and for 20 min of exercise sufficient to produce oronasal breathing. Fog exposures were followed by a methacholine (MCh) challenge (a measure of airway reactivity) or inhalation of technetium-99M radioaerosol (MMAD = 3.4 microns) on 2 study days each. Changes in symptoms and forced ventilatory function were also assessed. Clearance was quantified from computer-assisted analyses of gamma camera images of the lower respiratory tract in terms of %removal/min of the radiolabel from the trachea 25 min after inhalation and from the outer zone of the right lung after 1.9 to 3 h. Symptoms, forced ventilatory function, and MCh response were unaffected by either fog. Tracheal clearance was more rapid in four of four subjects after AF (0.83 +/- 1.58% removal/min) compared with that after SF (-0.54 +/- 0.85% removal/min). Outer zone clearance was more rapid in six of seven subjects after AF (0.22 +/- 0.15% removal/min) compared with that after SF (0.01 +/- 0.09% removal/min)

  6. Induced dural lymphangiogenesis facilities soluble amyloid-beta clearance from brain in a transgenic mouse model of Alzheimer's disease

    Directory of Open Access Journals (Sweden)

    Ya-Ru Wen

    2018-01-01

    Full Text Available Impaired amyloid-β clearance from the brain is a core pathological event in Alzheimer's disease. The therapeutic effect of current pharmacotherapies is unsatisfactory, and some treatments cause severe side effects. The meningeal lymphatic vessels might be a new route for amyloid-β clearance. This study investigated whether promoting dural lymphangiogenesis facilitated the clearance of amyloid-β from the brain. First, human lymphatic endothelial cells were treated with 100 ng/mL recombinant human vascular endothelial growth factor-C (rhVEGF-C protein. Light microscopy verified that rhVEGF-C, a specific ligand for vascular endothelial growth factor receptor-3 (VEGFR-3, significantly promoted tube formation of human lymphatic endothelial cells in vitro. In an in vivo study, 200 μg/mL rhVEGF-C was injected into the cisterna magna of APP/PS1 transgenic mice, once every 2 days, four times in total. Immunofluorescence staining demonstrated high levels of dural lymphangiogenesis in Alzheimer's disease mice. One week after rhVEGF-C administration, enzyme-linked immunosorbent assay results showed that levels of soluble amyloid-β were decreased in cerebrospinal fluid and brain. The Morris water maze test demonstrated that spatial cognition was restored. These results indicate that the upregulation of dural lymphangiogenesis facilities amyloid-β clearance from the brain of APP/PS1 mice, suggesting the potential of the VEGF-C/VEGFR-3 signaling pathway as a therapeutic target for Alzheimer's disease.

  7. 20 CFR 655.150 - Interstate clearance of job order.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  8. HPT Clearance Control: Intelligent Engine Systems-Phase 1

    Science.gov (United States)

    2005-01-01

    The following work has been completed to satisfy the Phase I Deliverables for the "HPT Clearance Control" project under NASA GRC's "Intelligent Engine Systems" program: (1) Need for the development of an advanced HPT ACC system has been very clearly laid out, (2) Several existing and potential clearance control systems have been reviewed, (3) A scorecard has been developed to document the system, performance (fuel burn, range, payload, etc.), thermal, and mechanical characteristics of the existing clearance control systems, (4) Engine size and flight cycle selection for the advanced HPT ACC system has been reviewed with "large engine"/"long range mission" combination showing the most benefit, (5) A scoring criteria has been developed to tie together performance parameters for an objective, data driven comparison of competing systems, and (6) The existing HPT ACC systems have been scored based on this scoring system.

  9. Treatment of resistant tattoos using a new generation Q-switched Nd:YAG laser: influence of beam profile and spot size on clearance success.

    Science.gov (United States)

    Karsai, Syrus; Pfirrmann, Gudrun; Hammes, Stefan; Raulin, Christian

    2008-02-01

    Multiple treatments of resistant tattoos often result in fibrosis and visible textural changes that lessen response to subsequent treatments. The aim of this study is to evaluate the influence of beam profile and spot size on clearance rates and side effects in the setting of resistant tattoos. Thirty-six professional, black tattoos (32 patients) were treated unsuccessfully with a Q-switched Nd:YAG laser (MedLite C3, HoyaConBio Inc., Fremont, CA). Because of therapy resistance all tattoos were re-treated using a new generation Nd:YAG laser (MedLite C6, HoyaConBio Inc.). Maximum energy fluence (E (max)), mean energy fluence, mean spot size, level of clearance, side effects and beam profile (irradiance distribution) of both laser systems were assessed and evaluated in a retrospective study. All tattoos were previously treated with the C3 laser at 1,064 nm using a mean E(max) of 5.8+/-0.8 J/cm(2) (range 3.8-7.5 J/cm(2)) as compared with a mean E(max) of 6.4+/-1.6 J/cm(2) (range 3.2-9.0 J/cm(2)) during the C6 treatment course. Corresponding spot sizes were larger during C6 treatments as compared with C3 (5.0+/-0.9 and 3.6+/-0.2 mm, respectively). The C6 laser had a "flat top" and homogenous profile regardless of the spot size. For the C3 laser the beam shape was "Gaussian," and the homogeneity was reduced by numerous micro-spikes and micro-nadirs. After the C6 treatment course 33.3% of the tattoos showed clearance of grade 1 (0-25%), 16.7% of grade 2 (26-50%), 16.7% of grade 3 (51-75%), 30.5% of grade 4 (76-95%), 2.8% of grade 5 (96-100%). The total rate of side effects due to C6 treatment was 8.3% in all tattoos (hyperpigmentation 5.6%, hypopigmentation 2.7%, textural changes/scars 0%). This clinical study documents for the first time the impact of a 1,064-nm Nd:YAG laser with a more homogenous beam profile and a larger spot size on the management of resistant tattoos. Only a few treatment sessions were necessary to achieve an additional clearance with a low rate of

  10. 32 CFR 154.16 - Security clearance.

    Science.gov (United States)

    2010-07-01

    ... part. The Director, Washington Headquarters Services (WHS) will initiate the required investigation... clearance, as appropriate. The Assistant Secretary of Defense (Legislative Affairs) will be notified by WHS...

  11. Estimation of normal chromium-51 ethylene diamine tetra-acetic acid clearance in children

    International Nuclear Information System (INIS)

    Piepsz, A.; Pintelon, H.; Ham, H.R.

    1994-01-01

    In order to estimate the normal range of chromium-51 ethylene diamine tetra-acetic acid (EDTA) clearance in children, we selected a series of 256 patients with past or present urinary tract infection who showed, at the time of the clearance determination, normal technetium-99m dimercaptosuccinic acid (DMSA) scintigraphy and normal left to right DMSA relative uptake. The clearance was calculated by means of either the simplified second exponential method or the 120-min single blood sample; Chantler's correction was used in order to correct for having neglected the first exponential. There was a progressive increase in clearance from the first weeks of life (mean value around 1 month: 55 ml/min/1.73 m 2 ), with a plateau at around 18 months. Between 2 and 17 years of age, the clearance values remained constant, with a mean value of 114 ml/min/1.73 m 2 (SD: 24 ml/min); this is similar to the level described for inulin clearance. No significant differences were observed between boys and girls, or between clearance values calculated with one or with two blood samples. Taking into account the hour of intravenous injection of the tracer, we did not observe any influence of the lunchtime meal on the distribution of the 51 Cr-EDTA clearance values. (orig.)

  12. Effect of prior immobilization on muscular glucose clearance in resting and running rats

    International Nuclear Information System (INIS)

    Vissing, J.; Ohkuwa, Tetsuo; Ploug, T.; Galbo, H.

    1988-01-01

    In vitro studies have shown that prior disuse impairs the glucose clearance of red skeletal muscle because of a developed insensitivity to insulin. We studied whether an impaired glucose clearance is present in vivo in 42-h immobilized muscles of resting rats and, furthermore, whether the exercise-induced increase in glucose clearance of red muscles is affected by prior immobilization. The 2-[ 3 H]deoxy-D-glucose (2DG) bolus injection method was used to determine glucose clearance of individual muscles. At rest, glucose clearance was markedly impaired in rats with previously immobilized red muscles compared with nonimmobilized control rats. During running, glucose clearance did not differ between muscles in previously immobilized and control rats. Insulin levels were always similar in the two groups and decreased during exercise. Intracellular nonphosphorylated 2DG was present in tissues with high glucose clearances. In conclusion, 42 h of immobilization markedly impairs glucose clearance of resting red muscle fibers in vivo. Apparently, physical inactivity in particular affects steps involved in insulin-mediated action that are not part of contraction-induced glucose uptake and metabolism. Presence of intracellular 2DG shows that separate determination of phosphorylated 2DG is necessary for accurate estimates of glucose metabolism and that accumulation of phosphorylated 2DG does not accurately reflect glucose transport

  13. Analysis of foot clearance in firefighters during ascent and descent of stairs.

    Science.gov (United States)

    Kesler, Richard M; Horn, Gavin P; Rosengren, Karl S; Hsiao-Wecksler, Elizabeth T

    2016-01-01

    Slips, trips, and falls are a leading cause of injury to firefighters with many injuries occurring while traversing stairs, possibly exaggerated by acute fatigue from firefighting activities and/or asymmetric load carriage. This study examined the effects that fatigue, induced by simulated firefighting activities, and hose load carriage have on foot clearance while traversing stairs. Landing and passing foot clearances for each stair during ascent and descent of a short staircase were investigated. Clearances decreased significantly (p < 0.05) post-exercise for nine of 12 ascent parameters and increased for two of eight descent parameters. Load carriage resulted in significantly decreased (p < 0.05) clearance over three ascent parameters, and one increase during descent. Decreased clearances during ascent caused by fatigue or load carriage may result in an increased trip risk. Increased clearances during descent may suggest use of a compensation strategy to ensure stair clearance or an increased risk of over-stepping during descent. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  14. Activation and clearance of vanadium alloys and beryllium multipliers in fusion reactors

    International Nuclear Information System (INIS)

    Bartenev, S.; Romanovskij, V.; Ciampichetti, A.; Zucchetti, M.; Forrest, R.; Kolbasov, B.; Romanov, P.

    2006-01-01

    Design of fusion reactors includes the development of low-activation materials. V-Cr-Ti alloys are among the candidate structural materials for the first wall and blanket, with the scarce and costly V as the main component. It is worth considering its regeneration and refabrication as well as to avoid its disposal as radioactive waste. However, to do so, it is necessary to bring its radioactivity down to sufficiently low levels. We have two possible goals: · Recycling (within the nuclear industry) for first wall and front blanket components. In that case, contact dose rate must be sufficiently low. · Clearance (release from nuclear regulatory control) for back blanket and backplate components. In that case, the clearance index must be below unity. In fact, for components less exposed to neutron activation, clearance may be reachable, after a conceivable period of decay. Maximum radionuclide concentrations in the alloys allowing their clearance were determined, using new IAEA Clearance Limits. For this purpose, also for less neutron-exposed structures, such as the back part of the blanket and the backplate, clearance is possible only if certain activation products are separated. As for recycling within the nuclear industry of first wall components, also for clearance it turns out that the development of isotope chemical separation techniques is interesting and necessary for our purposes. A suitable method for achieving the required substantial radioactivity reduction of activated V-Cr-Ti alloys is radiochemical extraction reprocessing, Such a technology, permitting to remove metallic activation products from spent materials, was developed and tested experimentally in Russia. Concerning clearance of less activated components, based on the estimated element distribution factors in the extraction and re-extraction processes, and computations, it was shown that the alloy components may be purified from the activation products, using this technology, down to an

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... NACFC Carolyn and C Richard Mattingly Leadership in Mental Health Care Award Mary M. Kontos Award NACFC Reflections ... help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway clearance. ... Instagram Email Find a Clinical Trial Help us blaze ...

  16. 7 CFR 1927.53 - Costs of title clearance and closing of transactions.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Costs of title clearance and closing of transactions... and Loan Closing § 1927.53 Costs of title clearance and closing of transactions. The borrower or the... payment of all costs of title clearance and closing of the transaction and will arrange for payment before...

  17. Experimental Investigation of Factors Influencing Operating Rotor Tip Clearance in Multistage Compressors

    Directory of Open Access Journals (Sweden)

    Reid A. Berdanier

    2015-01-01

    Full Text Available An analysis of compressor rotor tip clearance measurements using capacitance probe instrumentation is discussed for a three-stage axial compressor. Thermal variations and centrifugal effects related to rotational speed changes affect clearance heights relative to the assembled configuration. These two primary contributions to measured changes are discussed both independently and in combination. Emphasis is given to tip clearance changes due to changing loading condition and at several compressor operating speeds. Measurements show a tip clearance change approaching 0.1 mm (0.2% rotor span when comparing a near-choke operating condition to a near-stall operating condition for the third stage. Additional consideration is given to environmental contributions such as ambient temperature, for which changes in tip clearance height on the order of 0.05 mm (0.1% rotor span were noted for temperature variations of 15°C. Experimental compressor operating clearances are presented for several temperatures, operating speeds, and loading conditions, and comparisons are drawn between these measured variations and predicted changes under the same conditions.

  18. USING TERRESTRIAL LASER SCANNERS TO CALCULATE AND MAP VERTICAL BRIDGE CLEARANCE

    OpenAIRE

    C. Zhang; D. Arditi; Z. Chen

    2013-01-01

    The vertical clearance of a bridge over a highway is important in preventing oversized vehicles from hitting the bridge. The vertical clearance of a bridge is traditionally measured by using surveying equipment such as leveling rods and total stations. Typically, measurements are taken at multiple locations in order to determine the minimum vertical clearance under the bridge. This process is time and labor consuming. Also, these measurements may not be accurate because of the traffi...

  19. Brain-wide pathway for waste clearance captured by contrast-enhanced MRI

    OpenAIRE

    Iliff, Jeffrey J.; Lee, Hedok; Yu, Mei; Feng, Tian; Logan, Jean; Nedergaard, Maiken; Benveniste, Helene

    2013-01-01

    The glymphatic system is a recently defined brain-wide paravascular pathway for cerebrospinal fluid (CSF) and interstitial fluid (ISF) exchange that facilitates efficient clearance of solutes and waste from the brain. CSF enters the brain along para-arterial channels to exchange with ISF, which is in turn cleared from the brain along para-venous pathways. Because soluble amyloid β clearance depends on glymphatic pathway function, we proposed that failure of this clearance system contributes t...

  20. Gamma-variate plasma clearance versus urinary plasma clearance of 51Cr-EDTA in patients with cirrhosis with and without fluid retention

    DEFF Research Database (Denmark)

    Fuglsang, Stefan; Henriksen, Ulrik L; Hansen, Hanne Boskov

    2017-01-01

    In patients with fluid retention, the plasma clearance of (51) Cr-EDTA (Clexp obtained by multiexponential fit) may overestimate the glomerular filtration rate (GFR). The present study was undertaken to compare a gamma-variate plasma clearance (Clgv) with the urinary plasma clearance of (51) Cr......-EDTA (Clu ) in patients with cirrhosis with and without fluid retention. A total of 81 patients with cirrhosis (22 without fluid retention, 59 with ascites) received a quantitative intravenous injection of (51) Cr-EDTA followed by plasma and quantitative urinary samples for 5 h. Clgv was determined from...... the injected dose relative to the plasma concentration-time area, obtained by a gamma-variate iterative fit. Clexp and Clu were determined by standard technique. In patients without fluid retention, Clgv , Clexp and Clu were closely similar. The difference between Clgv and Clu (Clgv - Clu = ΔCl) was mean -0...

  1. Measurement of single kidney contrast media clearance by multiphasic spiral computed tomography: preliminary results

    International Nuclear Information System (INIS)

    Hackstein, N.; Puille, M.F.; Bak, Benjamin H.; Scharwat, Oliver; Rau, W.S.

    2001-01-01

    Objective. We present preliminary results of a new method (hereinafter called 'CT-clearance') to measure single kidney contrast media clearance by performing multiphasic helical CT of the kidneys. CT-clearance was calculated according to an extension of the Patlak-Plot. In contrast to prior investigators, who repeatedly measured a single slice, this method makes it possible to calculate single kidney clearance from at least three spiral CTs, utilizing the whole kidney volume. Methods. Spiral CT of the kidneys was performed unenhanced and about 30 and 100 s after administration of about 120 ml iopromide. Sum-density of the whole kidneys and aortic density was calculated from this data. Using this data, renal clearance of contrast media was calculated by CT-clearance in 29 patients. As reference, Serum-clearance was calculated in 24 patients by application of a modified one-exponential slope model. Information on the relative kidney function was gained by renal scintigraphy with Tc99m-MAG-3 or Tc99m-DMSA in 29 patients. Results. Linear regression analysis revealed a correlation coefficient of CT-clearance with Serum-clearance of r=0.78 with Cl (CT) [ml/min]=22.2+1.03 * Cl (serum), n=24. Linear regression of the relative kidney function (rkf) of the right kidney calculated by CT-clearance compared to scintigraphy results provided a correlation coefficient r=0.89 with rkf(CT)[%]=18.6+0.58 * rkf(scintigraphy), n=29. Conclusion. The obtained results of contrast media clearance measured by CT-clearance are in the physiological range of the parameter. Future studies should be performed to improve the methodology with the aim of higher accuracy. More specifically, better determination of the aortic density curve might improve the accuracy

  2. Lung clearance of {sup 99m} Tc- DTPA in systemic lupus erythematous

    Energy Technology Data Exchange (ETDEWEB)

    Dalcin, P.T.R; Barreto, S.S.M.; Xavier, R.M.; Brenol, J.C.T. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Hospital de Clinicas. Dept. de Medicina Interna; Cunha, R.D.; Marroni, B.J. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Hospital de Clinicas. Servico de Medicina Nuclear]. E-mail: rxavier@hcpa.ufrgs.br

    2002-06-01

    The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99 mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99 mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnoea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99 m Tc-DTPA is increased in SLE patients with active disease. (author)

  3. Comparison of arterial intimal clearances of LDL from diabetic and nondiabetic cholesterol-fed rabbits. Differences in intimal clearance explained by size differences

    International Nuclear Information System (INIS)

    Nordestgaard, B.G.; Zilversmit, D.B.

    1989-01-01

    Arterial intimal clearances of low density lipoproteins (LDL) from diabetic cholesterol-fed rabbits (D-LDL) and LDL from nondiabetic cholesterol-fed rabbits (N-LDL) were compared. In six experiments, D-LDL and N-LDL were isolated from a diabetic and a nondiabetic rabbit, were iodinated with 125I and 131I, respectively, were mixed, and were reinjected into the same two rabbits as well as into a normal rabbit. Fractional catabolic rates for D-LDL and N-LDL in normal rabbits were 0.065 and 0.074 h-1 (p less than 0.05), respectively. For five of the six pairs of LDL, the D-LDL was smaller than N-LDL as determined by gel filtration. The arterial permeability to N-LDL, when normalized for differences in arterial cholesterol content, did not appear to differ between diabetic and nondiabetic rabbits. The relative arterial intimal clearance (D-LDL/N-LDL) in arteries from diabetic and nondiabetic rabbits was inversely related to the relative molecular weight (D-LDL/N-LDL). For example, when the molecular weight of D-LDL was as low as 60% of that of N-LDL (i.e., the diameter of D-LDL was reduced 16%), the intimal clearance of D-LDL was 40% larger than that of N-LDL. When, on the other hand, molecular weights and diameters of the two LDL were similar, the intimal clearance was also quite similar. These results suggest that arterial intimal clearance of LDL from diabetic and nondiabetic cholesterol-fed rabbits is comparable unless the two types of LDL have a different size

  4. Clearance of the cervical spine in clinically unevaluable trauma patients.

    Science.gov (United States)

    Halpern, Casey H; Milby, Andrew H; Guo, Wensheng; Schuster, James M; Gracias, Vicente H; Stein, Sherman C

    2010-08-15

    Meta-analytic costeffectiveness analysis. Our goal was to compare the results of different management strategies for trauma patients in whom the cervical spine was not clinically evaluable due to impaired consciousness, endotracheal intubation, or painful distracting injuries. We performed a structured literature review related to cervical spine trauma, radiographic clearance techniques (plain radiography, flexion/extension, CT, and MRI), and complications associated with semirigid collar use. Meta-analytic techniques were used to pool data from multiple sources to calculate pooled mean estimates of sensitivities and specificities of imaging techniques for cervical spinal clearance, rates of complications from various clearance strategies and from empirical use of semirigid collars. A decision analysis model was used to compare outcomes and costs among these strategies. Slightly more than 7.5% of patients who are clinically unevaluable have cervical spine injuries, and 42% of these injuries are associated with spinal instability. Sensitivity of plain radiography or fluoroscopy for spinal clearance was 57% (95% CI: 57%-60%). Sensitivities for CT and MRI alone were 83% (82%-84%) and 87% (84%-89%), respectively. Complications associated with collar use ranged from 1.3% (2 days) to 7.1% (10 days) but were usually minor and short-lived. Quadriplegia resulting from spinal instability missed by a clearance test had enormous impacts on longevity, quality of life, and costs. These impacts overshadowed the effects of prolonged collar application, even when the incidence of quadriplegia was extremely low. As currently used, neuroimaging studies for cervical spinal clearance in clinically unevaluable patients are not cost-effective compared with empirical immobilization in a semirigid collar.

  5. Clearance of slightly radioactive material from radiological control in Germany

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    1995-01-01

    Clearance from radiological control of slightly radioactive material arising from operation or decommissioning of nuclear installations has been practiced in Germany for nearly two decades. Meanwhile, for the clearance of metal generally approved and applicable recommendations for clearance levels have been issued. For other materials like building waste, case-by-case decisions are made by the state licensing authorities. Efforts to implement consistent sets of clearance levels for all kinds of material are under way. As several decommissioning projects will soon generate large amounts of materials from dismantling, a solution needs to be reached soon. The legal framework in Germany governing the use of atomic energy consists of the Atomic Energy Act and several ordinances. Rules and guidelines including the recommendations of the German Commission for Radiation Protection (SSK) exist on a lower level and are not legally binding. Several generic studies for the derivation of clearance levels for metals and building debris with alpha, beta, and gamma contamination have been performed on behalf of the Federal Ministry for Environment, Nature Conservation and Nuclear Safety, which oriented themselves on an individual dose of 10 microSv/a in agreement with IAEA recommendations. Stochastic models have been used for establishing the connection between specific activity of the material to be released and the resulting individual doses, with significant advantages over deterministic scenarios. In the future, for new SSK recommendations or an ordinance on clearance, the increase of masses from demolition of installations, higher recycling rates in the conventional sector and harmonization with international regulations and standards have to be taken into account

  6. Mucociliary clearance, airway inflammation and nasal symptoms in urban motorcyclists

    Directory of Open Access Journals (Sweden)

    Tereza C.S. Brant

    2014-01-01

    Full Text Available OBJECTIVES: There is evidence that outdoor workers exposed to high levels of air pollution exhibit airway inflammation and increased airway symptoms. We hypothesized that these workers would experience increased airway symptoms and decreased nasal mucociliary clearance associated with their exposure to air pollution. METHODS: In total, 25 non-smoking commercial motorcyclists, aged 18-44 years, were included in this study. These drivers work 8-12 hours per day, 5 days per week, driving on urban streets. Nasal mucociliary clearance was measured by the saccharine transit test; airway acidification was measured by assessing the pH of exhaled breath condensate; and airway symptoms were measured by the Sino-nasal Outcome Test-20 questionnaire. To assess personal air pollution exposure, the subjects used a passive-diffusion nitrogen dioxide (NO2 concentration-monitoring system during the 14 days before each assessment. The associations between NO2 and the airway outcomes were analyzed using the Mann-Whitney test and the Chi-Square test. Clinicaltrials.gov: NCT01976039. RESULTS: Compared with clearance in healthy adult males, mucociliary clearance was decreased in 32% of the motorcyclists. Additionally, 64% of the motorcyclists had airway acidification and 92% experienced airway symptoms. The median personal NO2 exposure level was 75 mg/m3 for these subjects and a significant association was observed between NO2 and impaired mucociliary clearance (p = 0.036. CONCLUSION: Non-smoking commercial motorcyclists exhibit increased airway symptoms and airway acidification as well as decreased nasal mucociliary clearance, all of which are significantly associated with the amount of exposure to air pollution.

  7. Propofol clearance and volume of distribution are increased in patients with major burns.

    Science.gov (United States)

    Han, Tae-Hyung; Greenblatt, David J; Martyn, J A Jeevendra

    2009-07-01

    Propofol pharmacokinetics were examined in 17 adults with major burns during the hyperdynamic convalescent phase. Eighteen nonburned surgical patients served as controls. After a 2-mg/kg intravenous dose of propofol, blood samples were collected at multiple time points. Noncompartmental methods were used to calculate the pharmacokinetic parameters. The following indices were higher in burns than controls: propofol clearance (64+/-17 vs 29+/-4 mL/kg/min, Pclearance of propofol in burned patients may imply that these patients require higher doses or infusion rates of propofol to attain a target plasma concentration or pharmacodynamic effect.

  8. Clearance of building structures for conventional non-nuclear reuse

    International Nuclear Information System (INIS)

    Buss, K.; Boehringer, S.

    1998-01-01

    At the example of a fuel assembly plant the strategy of control measurements on building surfaces, which shall be conventionally reused after their clearance, is regarded. Based on the given clearance levels the used measuring methods, especially with regard of possibly covered or intruded uranium contamination, are shown. The possibility of using the in-situ-γ-spectroscopy is discussed. (orig.) [de

  9. Is the gravity effect of radiographic anatomic features enough to justify stone clearance or fragments retention following extracorporeal shock wave lithotripsy (SWL).

    Science.gov (United States)

    Mustafa, Mahmoud

    2012-08-01

    We determined whether the gravity effect of radiographic anatomic features on the preoperative urography (IVP) are enough to predict fragments clearance after shock wave lithotripsy (SWL). A Total of 282 patients with mean age 45.8 ± 13.2 years (189 male, 93 female), who underwent SWL due to renal calculi between October 2005 and August 2009 were enrolled. The mean calculi load was 155.72 ± 127.66 mm². The patients were stratified into three groups: patients with pelvis calculi (group 1); patients with upper or middle pole calculi (group 2) and patients with lower pole calculi (group 3). Three angles on the pretreatment IVP were measured: the inner angle between the axis of the lower pole infundibular and ureteropelvic axis (angle I); the inner angle between the lower pole infundibular axis and main axis of pelvis-ureteropelvic (UP) junction point (angle II) and the inner angle between the lower pole infundibular axis and perpendicular line (angle III). Multivariate analysis was used to define the significant predictors of stone clearance. The overall success rate was 85.81%. All angles, sessions number, shock waves number and stone burden were significant predictors of success in patients in group 1. However, in group 2 only angle II and in group 3 angles I and II had significant effect on stone clearance. Radiographic anatomic features have significant role in determining the stone-free rate following satisfactory fragmentation of renal stones with SWL. The measurement of infundibulopelvic angle in different manner helps to predict the stone-free status in patients with renal calculi located not only in lower pole, but also in renal pelvis and upper or middle pole. Gravity effect is not enough to justify the significant influence of the radiographic anatomic features on the stone clearance and fragments retention after SWL.

  10. CO2 clearance by membrane lungs.

    Science.gov (United States)

    Sun, Liqun; Kaesler, Andreas; Fernando, Piyumindri; Thompson, Alex J; Toomasian, John M; Bartlett, Robert H

    2018-05-01

    Commercial membrane lungs are designed to transfer a specific amount of oxygen per unit of venous blood flow. Membrane lungs are much more efficient at removing CO 2 than adding oxygen, but the range of CO 2 transfer is rarely reported. Commercial membrane lungs were studied with the goal of evaluating CO 2 removal capacity. CO 2 removal was measured in 4 commercial membrane lungs under standardized conditions. CO 2 clearance can be greater than 4 times that of oxygen at a given blood flow when the gas to blood flow ratio is elevated to 4:1 or 8:1. The CO 2 clearance was less dependent on surface area and configuration than oxygen transfer. Any ECMO system can be used for selective CO 2 removal.

  11. NRPB volunteer study: deposition and clearance of inhaled particles

    International Nuclear Information System (INIS)

    Etherington, G.; Smith, J.

    1996-01-01

    At the Board Meeting of the National Radiological Protection Board held on 15 February 1996, approval was given for an experimental study of the deposition and clearance of inhaled particles in the human nasal passage. This is the latest in a series of volunteer biokinetic studies that have been conducted at NRPB since its formation. This article explains the purpose of the study, how ethical approval was obtained, how the study will be performed, what volunteers will be asked to do, and what doses they will receive. Doses will of course be carefully controlled, and will be well below the annual limits set for such experiments. The success of the study is of course crucially dependent on recruitment of a sufficient number of volunteers. The aim of this article is to provide information to anyone who might be interested in volunteering. (UK)

  12. Nanomedicine strategies for sustained, controlled, and targeted treatment of cancer stem cells of the digestive system.

    Science.gov (United States)

    Xie, Fang-Yuan; Xu, Wei-Heng; Yin, Chuan; Zhang, Guo-Qing; Zhong, Yan-Qiang; Gao, Jie

    2016-10-15

    Cancer stem cells (CSCs) constitute a small proportion of the cancer cells that have self-renewal capacity and tumor-initiating ability. They have been identified in a variety of tumors, including tumors of the digestive system. CSCs exhibit some unique characteristics, which are responsible for cancer metastasis and recurrence. Consequently, the development of effective therapeutic strategies against CSCs plays a key role in increasing the efficacy of cancer therapy. Several potential approaches to target CSCs of the digestive system have been explored, including targeting CSC surface markers and signaling pathways, inducing the differentiation of CSCs, altering the tumor microenvironment or niche, and inhibiting ATP-driven efflux transporters. However, conventional therapies may not successfully eradicate CSCs owing to various problems, including poor solubility, stability, rapid clearance, poor cellular uptake, and unacceptable cytotoxicity. Nanomedicine strategies, which include drug, gene, targeted, and combinational delivery, could solve these problems and significantly improve the therapeutic index. This review briefly summarizes the ongoing development of strategies and nanomedicine-based therapies against CSCs of the digestive system.

  13. Dynamic analysis of cross shaft type universal joint with clearance

    International Nuclear Information System (INIS)

    Lu, Jian Wei; Wang, Gong Cheng; Chen, Hao; Vakakis, Alexander F.; Bergman, Lawrence A.

    2013-01-01

    Cross shaft type universal joint is widely used in ground vehicles to transfer torque between two intersecting axes, and its transmission feature can make a great contribution to NVH performance of the vehicle. We looked at the assembling clearance at cross shaft neck, and presented a dynamic model of cross shaft type universal joint with clearance at cross shaft neck. Two-state model is applied to describe the contact force between the cross shaft and driving joint fork based on Hertz theorem, and lumped mass method is applied to build up the dynamic model of the universal joint. Based on this model, numerical analysis is carried out to discuss the transmission feature of the universal joint with clearance at cross shaft neck, and the influence of clearance on the dynamic behavior of the system is evaluated with numerical results based on time history, power spectrum, and phase portrait. The method and conclusions presented are helpful to improvement of the transmission feature of cross shaft type universal joint.

  14. Uncertainty analysis of 99mTc-HEPIDA liver clearance determination

    International Nuclear Information System (INIS)

    Surma, M. J.

    2005-01-01

    The aim of the study was to obtain information on the accuracy and precision of 99mT c-HEPIDA hepatic (Cl H p) and plasma (Cl P l) clearances and selection of an appropriate estimator of the measurement uncertainty of a single determination of these quantities. In a simulation (Monte Carlo) experiment, it was assumed that the recorded results of plasma and hepatic clearances, as obtained from 185 patients, provided authentic information about 99mT c-HEPIDA behaviour in the body over a wide range of the clearances studied. The time-course 99mT c-HEPIDA concentration in blood plasma has been described by means of biexponential function with parameter values derived for each patient. For each patient, using these data and urinary excretion data, there had been 5000 simulations performed; in each of the latter, the directly measured numbers have been substituted by simulated ones, obtained by means of varying the real ones, using random generated values. These reflected errors of plasma and radioactive standard pipetting (from 1 to 5%) and stochasticity of counting radioactive decay (1%). The time of blood sampling and urine voiding was also varied, assuming realistic uncertainty. The varied values were then used for computation of the simulated clearances. From the 5000 calculated clearances for each patient, mean-values were calculated, as well as mean standard errors, standard deviations and mean uncertainty of measurements using a widely accepted rule of partial error propagation, and, in addition, a modified rule of the latter. Accuracy of clearance (Cl P l, Cl H p, Cl U r) determination was assessed on the basis of comparison of mean values from simulations with those from directly recorded values. Precision was identified with standard deviation of each of the 5000 simulations. The uncertainty thus obtained was compared with results of calculated traditional and modified uncertainty. There was good agreement between standard deviation of the simulations with

  15. Effect of prior immobilization on muscular glucose clearance in resting and running rats

    DEFF Research Database (Denmark)

    Vissing, J; Ohkuwa, T; Ploug, Thorkil

    1988-01-01

    with nonimmobilized control rats (red gastrocnemius 0.46 +/- 0.02 vs. 0.99 +/- 0.08 and soleus 1.10 +/- 0.30 vs. 3.97 +/- 0.54 ml.min-1.100 g-1, P less than 0.005). During running (18 m/min), glucose clearance did not differ between muscles in previously immobilized and control rats. Insulin levels were always......In vitro studies have shown that prior disuse impairs the glucose clearance of red skeletal muscle because of a developed insensitivity to insulin. We studied whether an impaired glucose clearance is present in vivo in 42-h immobilized muscles of resting rats and, furthermore, whether the exercise......-induced increase in glucose clearance of red muscles is affected by prior immobilization. The 2-[3H]deoxy-D-glucose (2DG) bolus injection method was used to determine glucose clearance of individual muscles. At rest, glucose clearance was markedly impaired in rats with previously immobilized red muscles compared...

  16. Online feedback-controlled renal constant infusion clearances in rats.

    Science.gov (United States)

    Schock-Kusch, Daniel; Shulhevich, Yury; Xie, Qing; Hesser, Juergen; Stsepankou, Dzmitry; Neudecker, Sabine; Friedemann, Jochen; Koenig, Stefan; Heinrich, Ralf; Hoecklin, Friederike; Pill, Johannes; Gretz, Norbert

    2012-08-01

    Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique.

  17. 2A4 binds soluble and insoluble light chain aggregates from AL amyloidosis patients and promotes clearance of amyloid deposits by phagocytosis †.

    Science.gov (United States)

    Renz, Mark; Torres, Ronald; Dolan, Philip J; Tam, Stephen J; Tapia, Jose R; Li, Lauri; Salmans, Joshua R; Barbour, Robin M; Shughrue, Paul J; Nijjar, Tarlochan; Schenk, Dale; Kinney, Gene G; Zago, Wagner

    2016-09-01

    Amyloid light chain (AL) amyloidosis is characterized by misfolded light chain (LC) (amyloid) deposition in various peripheral organs, leading to progressive dysfunction and death. There are no regulatory agency-approved treatments for AL amyloidosis, and none of the available standard of care approaches directly targets the LC protein that constitutes the amyloid. NEOD001, currently in late-stage clinical trials, is a conformation-specific, anti-LC antibody designed to specifically target misfolded LC aggregates and promote phagocytic clearance of AL amyloid deposits. The present study demonstrated that the monoclonal antibody 2A4, the murine form of NEOD001, binds to patient-derived soluble and insoluble LC aggregates and induces phagocytic clearance of AL amyloid in vitro. 2A4 specifically labeled all 21 fresh-frozen organ samples studied, which were derived from 10 patients representing both κ and λ LC amyloidosis subtypes. 2A4 immunoreactivity largely overlapped with thioflavin T-positive labeling, and 2A4 bound both soluble and insoluble LC aggregates extracted from patient tissue. Finally, 2A4 induced macrophage engagement and phagocytic clearance of AL amyloid deposits in vitro. These findings provide further evidence that 2A4/NEOD001 can effectively clear and remove human AL-amyloid from tissue and further support the rationale for the evaluation of NEOD001 in patients with AL amyloidosis.

  18. 2A4 binds soluble and insoluble light chain aggregates from AL amyloidosis patients and promotes clearance of amyloid deposits by phagocytosis †

    Science.gov (United States)

    Renz, Mark; Torres, Ronald; Dolan, Philip J.; Tam, Stephen J.; Tapia, Jose R.; Li, Lauri; Salmans, Joshua R.; Barbour, Robin M.; Shughrue, Paul J.; Nijjar, Tarlochan; Schenk, Dale; Kinney, Gene G.; Zago, Wagner

    2016-01-01

    Abstract Amyloid light chain (AL) amyloidosis is characterized by misfolded light chain (LC) (amyloid) deposition in various peripheral organs, leading to progressive dysfunction and death. There are no regulatory agency–approved treatments for AL amyloidosis, and none of the available standard of care approaches directly targets the LC protein that constitutes the amyloid. NEOD001, currently in late-stage clinical trials, is a conformation-specific, anti-LC antibody designed to specifically target misfolded LC aggregates and promote phagocytic clearance of AL amyloid deposits. The present study demonstrated that the monoclonal antibody 2A4, the murine form of NEOD001, binds to patient-derived soluble and insoluble LC aggregates and induces phagocytic clearance of AL amyloid in vitro. 2A4 specifically labeled all 21 fresh-frozen organ samples studied, which were derived from 10 patients representing both κ and λ LC amyloidosis subtypes. 2A4 immunoreactivity largely overlapped with thioflavin T–positive labeling, and 2A4 bound both soluble and insoluble LC aggregates extracted from patient tissue. Finally, 2A4 induced macrophage engagement and phagocytic clearance of AL amyloid deposits in vitro. These findings provide further evidence that 2A4/NEOD001 can effectively clear and remove human AL-amyloid from tissue and further support the rationale for the evaluation of NEOD001 in patients with AL amyloidosis. PMID:27494229

  19. Late engagement of CD86 after influenza virus clearance promotes recovery in a FoxP3+ regulatory T cell dependent manner.

    Directory of Open Access Journals (Sweden)

    Emily K Moser

    2014-08-01

    Full Text Available Influenza A virus (IAV infection in the respiratory tract triggers robust innate and adaptive immune responses, resulting in both virus clearance and lung inflammation and injury. After virus clearance, resolution of ongoing inflammation and tissue repair occur during a distinct recovery period. B7 family co-stimulatory molecules such as CD80 and CD86 have important roles in modulating T cell activity during the initiation and effector stages of the host response to IAV infection, but their potential role during recovery and resolution of inflammation is unknown. We found that antibody-mediated CD86 blockade in vivo after virus clearance led to a delay in recovery, characterized by increased numbers of lung neutrophils and inflammatory cytokines in airways and lung interstitium, but no change in conventional IAV-specific T cell responses. However, CD86 blockade led to decreased numbers of FoxP3+ regulatory T cells (Tregs, and adoptive transfer of Tregs into αCD86 treated mice rescued the effect of the blockade, supporting a role for Tregs in promoting recovery after virus clearance. Specific depletion of Tregs late after infection mimicked the CD86 blockade phenotype, confirming a role for Tregs during recovery after virus clearance. Furthermore, we identified neutrophils as a target of Treg suppression since neutrophil depletion in Treg-depleted mice reduced excess inflammatory cytokines in the airways. These results demonstrate that Tregs, in a CD86 dependent mechanism, contribute to the resolution of disease after IAV infection, in part by suppressing neutrophil-driven cytokine release into the airways.

  20. Exclusion, exemption, clearance European Union approach

    International Nuclear Information System (INIS)

    Janssens, A.

    1997-01-01

    The presentation overviews the following issues: Euratom Basic Safety Standards; administrative requirements; radiation protection of the population. Scope of the Standards: natural radiation sources; exclusion. Exemption; Clearance; Import of radioactive scrap metal

  1. A simple method for the verification of clearance levels for non-radioactive solid waste

    International Nuclear Information System (INIS)

    Holland, B.

    1997-01-01

    ANSTO's radiopharmaceutical production laboratories generate 25 m 3 of solid waste per month. Most of this waste is not radioactive. Up until recently the non-radioactive waste was cleared from the controlled area and stored for 10 halflives prior to disposal as normal solid refuse. To eliminate the storage and ''double handling'' of the large quantities of non-radioactive waste a simple clearance method was devised to allow direct disposal. This paper describes how clearance levels were determined. Here the term ''clearance level'' is used as a general term for the release of material regardless of whether it was previously subject to regulatory control. This contrasts with the IAEA definition of a clearance level and highlights a potential problem with the implementation of exemption levels to keep material out of regulatory control and the use of clearance levels to allow removal of materials from regulatory control. Several common hand held contamination monitors were tested to determine their limits of detection and ability to meet these clearance levels. The clearance method includes waste segregation and size limitation features to ensure the waste is monitored in a consistent manner, compatible with the limits of detection. The clearance levels achieved were subsequently found to be compatible with some of the unconditional clearance levels in IAEA-TECDOC-855 and the measurement method also meets the required features of that document. The ANSTO non-radioactive waste clearance system has been in operation for more than 12 months and has proved simple and effective to operate. Approximately 12m 3 of the solid waste is now been treated directly as normal solid refuse. This paper describes the ANSTO clearance system, the contamination monitor tests and details practical problems associated with the direct monitoring of solid waste, including averaging of the activity in the package. The paper also briefly highlights the potential problem with the use of

  2. Nuclear security. DOE actions to improve the personnel clearance program

    International Nuclear Information System (INIS)

    Fultz, Keith O.; Bannerman, Carl J.; Daniel, Beverly A.

    1988-11-01

    The status of the Department of Energy's (DOE) implementation of recommendations in our two reports on DOE's personnel security clearance program was determined. The recommendations were aimed at improving the timeliness, accuracy, and efficiency of personnel security clearance decisions. Specifically, the objective was to determine and report on steps DOE is taking to implement these recommendations. In summary, it was found that DOE has either initiated action or is studying ways to address all the recommendations, but none of the recommendations have been completely implemented. The effectiveness of the DOE actions will depend, in part, on the adequacy of its internal control system for overseeing and evaluating program operations. DOE's personnel security clearance program is intended to provide reasonable assurance that personnel with access to classified information and materials are trustworthy. The Department requests that the Office of Personnel Management or the Federal Bureau of Investigation collect personal data on each person who requires such access to do his or her job. Based on these background investigations, DOE officials authorize individuals whose personal histories indicate that they are trustworthy to have access to classified information, secured facilities, and controlled materials as needed to perform their jobs. DOE has five types of these authorizations or personnel security clearances and must update information on personnel holding each type at 5-year intervals to confirm their continuing reliability. The five types are based on the types of security interests to which the person needs access, e.g., persons needing nuclear weapons-related data must have a Q clearance, and persons with a top secret clearance can have access to national security data classified as top secret

  3. Hepatic macrophage complement receptor clearance function following injury.

    Science.gov (United States)

    Cuddy, B G; Loegering, D J; Blumenstock, F A; Shah, D M

    1986-03-01

    Previous work has demonstrated that in vivo hepatic macrophage complement receptor clearance function is depressed following thermal injury. The present study was carried out to determine if complement receptor function depression is associated with other states of depressed host defense. Hepatic complement receptor clearance function was determined from the hepatic uptake of rat erythrocytes coated with antierythrocyte IgM (EIgM) in rats. Receptor function was determined following cannulation of a carotid artery, laparotomy plus enterotomy, hemorrhagic shock, trauma, thermal injury, acute bacteremia, acute endotoxemia, and injection of erythrocyte stroma, gelatinized lipid emulsion, or colloidal carbon. Hepatic uptake of EIgM was depressed following each of these experimental interventions except arterial cannulation. This effect was shown not to be due to a decrease in hepatic blood flow or depletion of complement and was therefore due to a depression in hepatic macrophage complement receptor clearance function. Thus, impairment of hepatic macrophage complement receptor function is associated with several states of depressed host defense.

  4. Clearance potential of ITER vacuum vessel activated materials

    International Nuclear Information System (INIS)

    Cepraga, D.G.; Cambi, G.; Frisoni, M.

    2002-01-01

    To demonstrate fusion's environmental attractiveness over the entire life cycle, a waste analysis is mandatory. The clearance is recommended by IAEA for releasing activated solid materials from regulatory control and for waste management policy. The paper focuses on the approach used to support waste analyses for ITER Generic Site Safety Report. The Material Unconditional Clearance Index of all the materials/zones on the equatorial mid-plane of ITER machine have been evaluated, based on IAEA-TECDOC-855. The Bonami-Nitawl-XSDNRPM sequence of the Scale-4.4a code system (using Vitenea-J library) has been firstly used for radiation transport analyses. Then the Anita-2000 code package is used for the activation calculation. The paper presents also, as an example, an application of the clearance indexes estimation for the ITER vacuum vessel materials. The results of the Anita-2000 have been compared with those obtained using the Fispact-99 activation code. (author)

  5. The Project of Success

    DEFF Research Database (Denmark)

    Kreiner, Kristian

    more complicated matter than meeting targets. While success may ultimately be justified in terms of a correspondence between aims and achievements, the understanding of both aspects is highly dependent on the project process. An example of a successful project that did not meet the original performance...... targets will serve to show that success is at matter of perspective as much as it is a matter of achievement. Other types of research, e.g. social psychology, have addressed the issue of success more explicitly. I draw on such literature to conceptualize project success anew and to reestablish...

  6. Contrast media and glomerular filtration: dose dependence of clearance for three agents

    International Nuclear Information System (INIS)

    Baeck, S.E.K.; Krutzen, E.; Nilsson-Ehle, P.

    1988-01-01

    Determination of plasma clearance of contrast agents has been advocated as a means to assess glomerular filtration rate. To evaluate the feasibility of different agents for this purpose, we have compared, in healthy volunteers, the dose dependence of plasma clearance for three contrast media (iohexol, a nonionic agent, and iothalamate and metrizoate, which are ionic substances), with special emphasis on the lower dose range (2-20 mL corresponding to 0.9-12.9 g, depending on dose and agent). Iohexol and iothalamate were cleared at constant rates, irrespective of given dose, whereas metrizoate clearance increased significantly at lower doses. In general, the clearances or iothalamate and metrizoate were, respectively, moderately and markedly higher than that of iohexol. The clearance of different doses of metrizoate (2 mL versus a radiographic dose of 40 mL or more) was also compared with the clearance of [ 51 Cr]EDTA in two groups of patients with reduced renal function. When compared with [ 51 Cr]EDTA in patients with renal dysfunction, metrizoate was cleared significantly faster after a 2-mL dose, whereas clearances were identical when the metrizoate dose was 40 mL or more. These findings indicate that tubular secretion plays an active role in the elimination of metrizoate. The pharmacokinetic properties of iohexol, in combination with its low toxicity, make it a suitable agent for determination of glomerular filtration rate in clinical practice

  7. Clearance from the anterior chamber of RBCs from human diabetics

    International Nuclear Information System (INIS)

    Williams, G.A.; Hatchell, D.L.; Collier, B.D.; Knobel, J.

    1984-01-01

    Erythrocytes from diabetic patients manifest decreased deformability and increased adherence. These abnormal membrane properties may diminish the ability of erythrocytes (RBCs) from diabetics to undergo deformation in passage through the trabecular meshwork. Using sodium chromate Cr 51-labeled RBCs from type I diabetic patients with proliferative retinopathy and normal control subjects, we studied RBC clearance from the rabbit anterior chamber. The mean time for 50% clearance (T50) of RBCs from diabetics (76 hours) was significantly longer than that for RBCs from normal subjects (19.5 hours). In this model, RBCs from diabetics have a slower clearance from the anterior chamber than do RBCs from normal subjects

  8. Experimental Study of Unshrouded Impeller Pump Stage Sensitivity to Tip Clearance

    Science.gov (United States)

    Williams, Robert W.; Zoladz, Thomas; Storey, Anne K.; Skelley, Stephen E.

    2002-01-01

    This viewgraph presentation provides information on an experiment. Its objective is to experimentally determine unshrouded impeller performance sensitivity to tip clearance. The experiment included: Determining impeller efficiency at scaled operating conditions in water at MSFC's Pump Test Equipment (PTE) Facility; Testing unshrouded impeller at three different tip clearances; Testing each tip clearance configuration at on- and off-design conditions, and collecting unsteady- and steady-state data in each configuration; Determining impeller efficiency directly using drive line torquemeter and pump inlet and exit total pressure measurements.

  9. Scan Manifestations and Blood Clearance Rates in Typhoid Liver

    International Nuclear Information System (INIS)

    Bahk, Yong Whee; Ahn, Jae Sung; Kim, Soon Hi

    1970-01-01

    Fourteen patients with typhoid fever studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold ( 198 Au). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 percent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 percent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increase in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or less a normal) clearance time are characteristic of typhoid fever.

  10. Kinematics Simulation Analysis of Packaging Robot with Joint Clearance

    Science.gov (United States)

    Zhang, Y. W.; Meng, W. J.; Wang, L. Q.; Cui, G. H.

    2018-03-01

    Considering the influence of joint clearance on the motion error, repeated positioning accuracy and overall position of the machine, this paper presents simulation analysis of a packaging robot — 2 degrees of freedom(DOF) planar parallel robot based on the characteristics of high precision and fast speed of packaging equipment. The motion constraint equation of the mechanism is established, and the analysis and simulation of the motion error are carried out in the case of turning the revolute clearance. The simulation results show that the size of the joint clearance will affect the movement accuracy and packaging efficiency of the packaging robot. The analysis provides a reference point of view for the packaging equipment design and selection criteria and has a great significance on the packaging industry automation.

  11. The microbiota mediates pathogen clearance from the gut lumen after non-typhoidal Salmonella diarrhea.

    Directory of Open Access Journals (Sweden)

    Kathrin Endt

    Full Text Available Many enteropathogenic bacteria target the mammalian gut. The mechanisms protecting the host from infection are poorly understood. We have studied the protective functions of secretory antibodies (sIgA and the microbiota, using a mouse model for S. typhimurium diarrhea. This pathogen is a common cause of diarrhea in humans world-wide. S. typhimurium (S. tm(att, sseD causes a self-limiting gut infection in streptomycin-treated mice. After 40 days, all animals had overcome the disease, developed a sIgA response, and most had cleared the pathogen from the gut lumen. sIgA limited pathogen access to the mucosal surface and protected from gut inflammation in challenge infections. This protection was O-antigen specific, as demonstrated with pathogens lacking the S. typhimurium O-antigen (wbaP, S. enteritidis and sIgA-deficient mice (TCRβ(-/-δ(-/-, J(H (-/-, IgA(-/-, pIgR(-/-. Surprisingly, sIgA-deficiency did not affect the kinetics of pathogen clearance from the gut lumen. Instead, this was mediated by the microbiota. This was confirmed using 'L-mice' which harbor a low complexity gut flora, lack colonization resistance and develop a normal sIgA response, but fail to clear S. tm(att from the gut lumen. In these mice, pathogen clearance was achieved by transferring a normal complex microbiota. Thus, besides colonization resistance ( = pathogen blockage by an intact microbiota, the microbiota mediates a second, novel protective function, i.e. pathogen clearance. Here, the normal microbiota re-grows from a state of depletion and disturbed composition and gradually clears even very high pathogen loads from the gut lumen, a site inaccessible to most "classical" immune effector mechanisms. In conclusion, sIgA and microbiota serve complementary protective functions. The microbiota confers colonization resistance and mediates pathogen clearance in primary infections, while sIgA protects from disease if the host re-encounters the same pathogen. This has

  12. Development of (99m)Tc-labeled asymmetric urea derivatives that target prostate-specific membrane antigen for single-photon emission computed tomography imaging.

    Science.gov (United States)

    Kimura, Hiroyuki; Sampei, Sotaro; Matsuoka, Daiko; Harada, Naoya; Watanabe, Hiroyuki; Arimitsu, Kenji; Ono, Masahiro; Saji, Hideo

    2016-05-15

    Prostate-specific membrane antigen (PSMA) is expressed strongly in prostate cancers and is, therefore, an attractive diagnostic and radioimmunotherapeutic target. In contrast to previous reports of PMSA-targeting (99m)Tc-tricarbonyl complexes that are cationic or lack a charge, no anionic (99m)Tc-tricarbonyl complexes have been reported. Notably, the hydrophilicity conferred by both cationic and anionic charges leads to rapid hepatobiliary clearance, whereas an anionic charge might better enhance renal clearance relative to a cationic charge. Therefore, an improvement in rapid clearance would be expected with either cationic or anionic charges, particularly anionic charges. In this study, we designed and synthesized a novel anionic (99m)Tc-tricarbonyl complex ([(99m)Tc]TMCE) and evaluated its use as a single-photon emission computed tomography (SPECT) imaging probe for PSMA detection. Direct synthesis of [(99m)Tc]TMCE from dimethyl iminodiacetate, which contains both the asymmetric urea and succinimidyl moiety important for PSMA binding, was performed using our microwave-assisted one-pot procedure. The chelate formation was successfully achieved even though the precursor included a complicated bioactive moiety. The radiochemical yield of [(99m)Tc]TMCE was 12-17%, with a radiochemical purity greater than 98% after HPLC purification. [(99m)Tc]TMCE showed high affinity in vitro, with high accumulation in LNCaP tumors and low hepatic retention in biodistribution and SPECT/CT studies. These findings warrant further evaluation of [(99m)Tc]TMCE as an imaging agent and support the benefit of this strategy for the design of other PSMA imaging probes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Plasma Creatinine Clearance in the Dog

    Science.gov (United States)

    Frazier, Loy W.

    1977-01-01

    Lists materials and methods for an experiment that demonstrates the concept of glomerular filtration rate (GFR) using anesthesized dogs. In the dog, GFR is equivalent to the renal plasma clearance of exogenous creatinine. (CS)

  14. ADCC-Mediated CD56DIM NK Cell Responses Are Associated with Early HBsAg Clearance in Acute HBV Infection.

    Science.gov (United States)

    Yu, Wen-Han; Cosgrove, Cormac; Berger, Christoph T; Cheney, Patrick C; Krykbaeva, Marina; Kim, Arthur Y; Lewis-Ximenez, Lia; Lauer, Georg M; Alter, Galit

    2018-01-01

    Hepatitis B virus (HBV) affects up to 400 million people worldwide and accounts for approximately one million deaths per year from liver pathologies. Current treatment regimens are effective in suppressing viremia but usually have to be taken indefinitely, warranting research into new therapeutic approaches. Acute HBV infection in adults almost universally results in resolution of viremia, with the exception of immunocompromised persons, suggesting that the immune response can functionally cure or even eradicate HBV infection. Because immunophenotypic and functional studies have implicated a role for Natural Killer (NK) cells in HBV clearance during acute infection, we hypothesized that a distinct NK-cell profile exists in acute HBV infection that could provide information for the mechanism of HBV clearance. Using multivariate flow cytometry, we evaluated the expression of key activating and inhibitory receptors on NK cells, and their ability to respond to classic target cell lines. Multivariate analysis revealed selective perturbation of the CD56 dim NK-cell subset during acute infection, displaying low levels of NKp46+, NKp30+, CD160+ and CD161+ cells. Intriguingly, the CD56 dim NK-cell profile predicted time to HBV surface antigen (HBsAg) clearance from the blood, and distinct NK-cell profiles predicted early (NKp30, CD94, CD161) and late clearance (KIR3DL1, CD158a, perforin, NKp46). Finally, functional analysis demonstrated that early and late clearance tracked with elevated degranulation (CD107a) or IFNγ production, respectively, in response to ADCC-mediated activation. The cytolytic CD56 dim NK-cell subset is selectively activated in acute HBV infection and displays distinct phenotypic and functional profiles associated with efficient and early control of HBV, implicating antibody-mediated cytolytic NK-cell responses in the early control and functional cure of HBV infection.

  15. Renal clearance of /sup 99m/Tc-methylene-diphosphonate in human beings

    Energy Technology Data Exchange (ETDEWEB)

    Vattimo, A.

    1987-12-01

    The renal clearance of /sup 99m/Tc-MDP was measured in 13 patients who had bone scans and compared with the renal clearance of /sup 51/Cr-EDTA. No difference was found between the renal clearance of the two tracers, showing a close correlation (r = 0.98). These data suggest that the /sup 99m/Tc-MDP is excreted by the kidneys by glomerular filtration without tubular secretion.

  16. Frequency and factors effecting non clearance of lower pole renal stones

    International Nuclear Information System (INIS)

    Ullah, A.; Zubair, M.; Khan, N.; Malik, A.

    2015-01-01

    Renal stone disease is a major health hazard in Pakistan and extra-corporeal shockwave lithotripsy is one of comprehensive method used to treat these stones. The aim of this study is to determine the frequency of factors affecting the non-clearance of stone fragments of lower pole renal stone after extra corporeal shockwave lithotripsy. The study was done with the objective to determine the frequency the spatial anatomical factors which can influence the non-clearance of lower pole stone fragments after ESWL. Methods: One and nineteen (119) patients with lower pole renal stone less than 10 mm were subjected to maximum 3 sessions of extracorporeal shock wave lithotripsy. KUB radiographs, ultrasonography and intravenous urography were used as investigative tools for lower pole renal calyceal anatomy. X ray KUB and ultrasound were done after a week for clearance. Data was analysed with the help of SPSS version 10.0 and presented in the forms of tables and graphs. Results: There were 77 (64.71%) males and 42 (35.29%) females. Infundibulo-pelvic angle (IPA)>40 degree was present in 93 (78.15%), Infundibular length (IL) <22 mm in 107 (89.92%) and Infundibular width (IW) >4 mm was present in 100 (84.03%) patients. The frequency of stone non clearance was noted in 31 (26.05%). Infundibulo-pelvic angle (IPA)>40 degree (p=0.000), Infundibular length (IL)<22 mm (p=0.001) and Infundibular width (IW)>4 mm (p=0.046) were significant variables affecting stone clearance. Conclusion: The frequency of non-clearance of lower calyx of kidney stone is 26.05%. The clearance of fragments of the lower calyx kidney stones is affected by three spatial anatomical factors, i.e., Infundibulopelvic angle, Infundibular width and infundibular length. (author)

  17. Delayed clearance of serum HBsAg in compensated cirrhosis B

    DEFF Research Database (Denmark)

    Fattovich, G; Giustina, G; Sanchez-Tapias, J

    1998-01-01

    The aim of this study was to evaluate the incidence, prognostic factors and clinical significance of delayed clearance of serum HBsAg in compensated cirrhosis B.......The aim of this study was to evaluate the incidence, prognostic factors and clinical significance of delayed clearance of serum HBsAg in compensated cirrhosis B....

  18. Turbulent Heat Transfer of a Finned Plate in a Duct as Tip Clearance Changes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hae-Kyun; Chung, Bum-Jin [Kyung Hee University, Yongin (Korea, Republic of)

    2015-05-15

    Fins are employed to enhance the cooling performance of a system. There are a number of studies relevant to geometry of fins. Meanwhile, the studies relevant to tip clearance, have not performed enough, which is the distance between the tips of the fins and the wall. We investigated the optimal tip clearance, which maximizes the heat transfers by experimental and numerical analyses with wider range of Re{sub Dh} than the previous studies. Turbulent heat transfers of a finned plate were measured. For an extended range of tip clearance and Re{sub Dh} than other studies. A joint experimental and numerical analyses was performed to measure heat transfers. Mass transfer experiments using electroplating system was used and FLUENT 6.3.26 was used for the calculation. For the narrow tip clearances below 5 mm, were investigated by numerical method only. The bypass flow to the tip clearance region contributes to heat transfer area at the tip clearance region and does not contributes that of the fin region. Thus, the optimal tip clearance was founded and it exists vicinity of 0.2 mm.

  19. Novel sensors to enable closed-loop active clearance control in gas turbine engines

    Science.gov (United States)

    Geisheimer, Jonathan; Holst, Tom

    2014-06-01

    Active clearance control within the turbine section of gas turbine engines presents and opportunity within aerospace and industrial applications to improve operating efficiencies and the life of downstream components. Open loop clearance control is currently employed during the development of all new large core aerospace engines; however, the ability to measure the gap between the blades and the case and close down the clearance further presents as opportunity to gain even greater efficiencies. The turbine area is one of the harshest environments for long term placement of a sensor in addition to the extreme accuracy requirements required to enable closed loop clearance control. This paper gives an overview of the challenges of clearance measurements within the turbine as well as discusses the latest developments of a microwave sensor designed for this application.

  20. Does sleep disturbance affect the amyloid clearance mechanisms in Alzheimer's disease?

    Science.gov (United States)

    Yulug, Burak; Hanoglu, Lutfu; Kilic, Ertugrul

    2017-10-01

    Sleep is an important factor that plays a key role in Alzheimer's disease pathogenesis. However, it is still unclear whether poor-quality sleep may overlap with sleep disturbances in the underlying dysfunctional mechanisms of amyloid beta (Aβ) clearance metabolism. Here, we aimed to evaluate the current evidence on the role of sleep deprivation in Aβ clearance metabolism. To that end, we discuss possible mechanisms underlying the bidirectional interaction between the sleep deprivation and Aβ clearance pathways. © 2017 The Authors. Psychiatry and Clinical Neurosciences © 2017 Japanese Society of Psychiatry and Neurology.

  1. 76 FR 59379 - Proposed Information Collection; Comment Request; Generic Clearance for Research in Development...

    Science.gov (United States)

    2011-09-26

    ...-XXXX. Type of Review: Generic Clearance Request. Title: Generic Clearance for Research in Development... information collected through qualitative evaluation methods will inform the disclosure form's design and... Proposed Information Collection; Comment Request; Generic Clearance for Research in Development of...

  2. Reduced effectiveness of escitalopram in the forced swimming test is associated with increased serotonin clearance rate in food restricted rats

    Science.gov (United States)

    France, CP; Li, J-X; Owens, WA; Koek, W; Toney, GM; Daws, LC

    2012-01-01

    Efficacy of antidepressant drugs is often limited. One of the limiting factors may be diet. This study shows that the effect of escitalopram in the forced swimming test is diminished in rats by food restriction that decreased body weight by 8%. The primary target for escitalopram is the serotonin (5-HT) transporter. Using high-speed chronoamperometry to measure 5-HT clearance in vivo in rats fed the same food restricted diet, the rate of 5-HT clearance from extracellular fluid in brain was dramatically increased. Increased 5-HT transporter function under conditions of dietary restriction might contribute to the decreased effect of escitalopram. These results suggest that diet plays an integral role in determining efficacy of antidepressant drugs, and might well generalize to other psychoactive drugs that impinge upon the 5-HT transporter. PMID:19419596

  3. A comparison of analytic procedures for measurement of fractional dextran clearances

    NARCIS (Netherlands)

    Hemmelder, MH; de Jong, PE; de Zeeuw, D

    Fractional dextran clearances have been extensively used to study glomerular size selectivity. We report on an analysis of different laboratory procedures involved in measuring fractional dextran clearances. The deproteinization of plasma samples by 20% trichloroacetic acid (TCA) revealed a protein

  4. Spontaneous Clearance of Hepatitis C after Liver and Renal Transplantation

    Directory of Open Access Journals (Sweden)

    CH Dale

    2009-01-01

    Full Text Available Spontaneous clearance of hepatitis C virus (HCV is rare in immunocompromised patients, such as those who have undergone organ transplantation. It has been recognized that patients receiving liver transplantation for HCV-related disease have decreased graft and patient survival compared with those transplanted for other etiologies. There is a growing trend toward treating HCV recurrence aggressively after liver transplantation. For other organ transplant recipients with concurrent HCV, treatment is not often an option, given the high rates of graft rejection and loss secondary to interferon and its immunomodulatory effects. Although spontaneous clearance of HCV has been reported in recipients of solitary liver and renal transplants, a common factor arising in these cases has been previous exposure to interferon. To date, no reports of spontaneous clearance of HCV RNA have been reported in a multiorgan transplant recipient. A case of spontaneous clearance of HCV RNA in an immunocompromised patient, within five months of simultaneous liver and kidney retransplantation is described. Importantly, this patient had no previous exposure to interferon.

  5. Derivation methods for clearance levels applied to reactors

    International Nuclear Information System (INIS)

    Okoshi, Minoru; Seki, Takeo

    2001-01-01

    In order to support the discussion by the Nuclear Safety Commission, JAERI derived the unconditional clearance levels for concrete and metal arising from the operation and dismantling of nuclear reactors. The clearance levels of 20 radionuclides were derived from 10 μSv/y of individual doses by deterministic approach. In this approach, calculation models were established to assess individual doses resulting from 73 exposure pathways related to disposal and recycle/reuse, and realistic parameter values were selected considering Japanese natural and social conditions. The appropriateness of selected parameter values was confirmed by stochastic analyses. (author)

  6. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....

  7. Scan Manifestations and Blood Clearance Rates in Typhoid Liver

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong Whee; Ahn, Jae Sung; Kim, Soon Hi [St. Mary' s Hospital, Catholic Medical College, Seoul (Korea, Republic of)

    1970-09-15

    Fourteen patients with typhoid fever studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold ({sup 198}Au). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 percent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 percent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increase in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or less a normal) clearance time are characteristic of typhoid fever.

  8. Clearance of labelled creatinine

    International Nuclear Information System (INIS)

    Eberstadt, P.; Liverant, J.

    1982-01-01

    Creatinine, extensively used in clinical work to evaluate glomerular filtration rate (G.F.R.) has caused controversy. Using simultaneously on dogs a gamma emitting agent measuring G.F.R., creatinine clearance proved to be higher. Aided by quantitative determinations and compartmental analysis fortunately the respective dilution spaces can be calculated. In the majority of these animals creatinine spaces are larger but in some equal to the ones of inulin

  9. Relationship of end-expiratory pressure, lung volume, and /sup 99m/Tc-DTPA clearance

    International Nuclear Information System (INIS)

    Cooper, J.A.; van der Zee, H.; Line, B.R.; Malik, A.B.

    1987-01-01

    We investigated the dose-response effect of positive end-expiratory pressure (PEEP) and increased lung volume on the pulmonary clearance rate of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). Clearance of lung radioactivity was expressed as percent decrease per minute. Base-line clearance was measured while anesthetized sheep (n = 20) were ventilated with 0 cmH 2 O end-expiratory pressure. Clearance was remeasured during ventilation at 2.5, 5, 10, 15, or 20 cmH 2 O PEEP. Further studies showed stepwise increases in functional residual capacity (FRC) (P less than 0.05) measured at 0, 2.5, 5, 10, 15, and 20 cmH 2 O PEEP. At 2.5 cmH 2 O PEEP, the clearance rate was not different from that at base line (P less than 0.05), although FRC was increased from base line. Clearance rate increased progressively with increasing PEEP at 5, 10, and 15 cmH 2 O (P less than 0.05). Between 15 and 20 cmH 2 O PEEP, clearance rate was again unchanged, despite an increase in FRC. The pulmonary clearance of aerosolized /sup 99m/Tc-DTPA shows a sigmoidal response to increasing FRC and PEEP, having both threshold and maximal effects. This relationship is most consistent with the hypothesis that alveolar epithelial permeability is increased by lung inflation

  10. Foot clearance and variability in mono- and multifocal intraocular lens users during stair navigation.

    Science.gov (United States)

    Renz, Erik; Hackney, Madeleine; Hall, Courtney

    2016-01-01

    Intraocular lenses (IOLs) provide distance and near refraction and are becoming the standard for cataract surgery. Multifocal glasses increase variability of toe clearance in older adults navigating stairs and increase fall risk; however, little is known about the biomechanics of stair navigation in individuals with multifocal IOLs. This study compared clearance while ascending and descending stairs in individuals with monofocal versus multifocal IOLs. Eight participants with multifocal IOLs (4 men, 4 women; mean age = 66.5 yr, standard deviation [SD] = 6.26) and fifteen male participants with monofocal IOLs (mean age = 69.9 yr, SD = 6.9) underwent vision and mobility testing. Motion analysis recorded kinematic and custom software-calculated clearances in three-dimensional space. No significant differences were found between groups on minimum clearance or variability. Clearance differed for ascending versus descending stairs: the first step onto the stair had the greatest toe clearance during ascent, whereas the final step to the floor had the greatest heel clearance during descent. This preliminary study indicates that multifocal IOLs have similar biomechanic characteristics to monofocal IOLs. Given that step characteristics are related to fall risk, we can tentatively speculate that multifocal IOLs may carry no additional fall risk.

  11. Low serum hyaluronic acid levels associated with spontaneous HBsAg clearance

    NARCIS (Netherlands)

    Harkisoen, S.; Arends, J. E.; van den Hoek, A.; van Erpecum, K. J.; Boland, G. J.; Hoepelman, A. I. M.

    2015-01-01

    Purpose The pathophysiological underlying mechanism of spontaneous HBsAg clearance in hepatitis B virus (HBV) infected patients is largely unknown. However, serum hyaluronic acid (sHA) plays a role in liver fibrosis progression and reversely could serve as a potential biomarker for HBsAg clearance.

  12. A pre- and postoperative study of split isotope clearance in childhood

    International Nuclear Information System (INIS)

    Faerber, D.; Czempiel, H.; Muehle, P.; Schick, F.; Wenzl, H.; Technische Univ. Muenchen; Technische Univ. Muenchen

    1979-01-01

    In 1978 43 patients have been operated in the Department of Pediatric Surgery, Krankenhaus Muenchen-Schwabing, because of recurrent urinary-tract infections with ureterovesical reflux or obstructive urinary-tract diseases. In all patients a split whole body clearance-study with a method modified after the method of Muehle with 131 J-Hippuran was carried out pre- or postoperatively, respectively. In 78,5% of these cases the clearance-results were corresponding to the results of X-ray examination; 6 of the remaining patients had a worse clearance result and 3 had a better result than the X-ray findings would have suggested. (orig.) [de

  13. Scan Manifestation and Trace-Dose Radiogold Clearance Rates in Obstructive Jaundice

    International Nuclear Information System (INIS)

    Kim, Dong Jip; Bahk, Yong Whee; Shinn, Kyung Sub

    1969-01-01

    The present study has been undertaken to analyze scan manifestation in obstructive jaundice. Scan changes were correlated with the duration of jaundice. In addition, clearance rates of trace dose of colloidal radiogold were assessed in each case. The materials were consisted of 19 cases with surgically and/or histopathologically verified obstructive jaundice from various causes including common duct stone, empyema of the gall bladder and carcinoma of the pancreas head etc. Blood clearance rates of colloidal 198 Au were determined after the injection of 8 uCi by simple geometrical drawing of recorded strip charts. Scan was performed following additional injection of the sam radiogold. In 16 out of 19 cases, the scan rather typical 'arborifrom' mottlings around the porta hepatis. The intensity and appearance of such mottlings on the scan was related with the duration of jaundice and level of serum bilirubin and alkaline phosphatase. The blood clearance rates remained to be within normal range in 74 percent of the patients. In the remaining 26 percent, clearance rate ranged between 4.1 and 6 minutes. It is concluded that the association of 'arboriform' mottlings and normal or mildly delayed clearance rates in the patients with jaundice is characteristic of obstructive change in the biliary system.

  14. Scan Manifestation and Trace-Dose Radiogold Clearance Rates in Obstructive Jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Jip; Bahk, Yong Whee; Shinn, Kyung Sub [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1969-09-15

    The present study has been undertaken to analyze scan manifestation in obstructive jaundice. Scan changes were correlated with the duration of jaundice. In addition, clearance rates of trace dose of colloidal radiogold were assessed in each case. The materials were consisted of 19 cases with surgically and/or histopathologically verified obstructive jaundice from various causes including common duct stone, empyema of the gall bladder and carcinoma of the pancreas head etc. Blood clearance rates of colloidal {sup 198}Au were determined after the injection of 8 uCi by simple geometrical drawing of recorded strip charts. Scan was performed following additional injection of the sam radiogold. In 16 out of 19 cases, the scan rather typical 'arborifrom' mottlings around the porta hepatis. The intensity and appearance of such mottlings on the scan was related with the duration of jaundice and level of serum bilirubin and alkaline phosphatase. The blood clearance rates remained to be within normal range in 74 percent of the patients. In the remaining 26 percent, clearance rate ranged between 4.1 and 6 minutes. It is concluded that the association of 'arboriform' mottlings and normal or mildly delayed clearance rates in the patients with jaundice is characteristic of obstructive change in the biliary system.

  15. Clearance Analysis of CTC2 (on ELC4) to S-TRRJ HRS Radiator Rotation Envelope

    Science.gov (United States)

    Liddle, Donn

    2014-01-01

    ) as defined by nine preexisting Space Vision System (SVS) targets affixed to the forward/zenith side of the S1 and S3 truss segments. The location of the outboard edge of the S-TRRJ radiator would also be measured when positioned at the angle of closest approach to CTC2 (gamma = 35.0 degrees). This data would allow the Digital Pre-Assembly Group to predict how the ELC4 would sit on the UCCAS and how that would translate into the clearance between CTC2 and the S-TRRJ radiators. Phase II: After the ELC4 was delivered and installed into the UCCAS, the position of the CTC2 mounting plate on the inboard face of ELC4, would be measured in the ISSACS coordinate system relative to the SVS control points used in Phase I. Although CTC2 would not yet be mounted on ELC4, the working envelope of CTC2 could be mathematically added to the measured position of ELC4 to produce a best estimate for CTC2's mounted location. Comparing CTC2's best estimated location to the S-TRRJ radiator (measured in Phase I); relative to the ISSACS coordinate system, would provide a direct measurement of the expected clearance. Due to the impending delivery of ELC4 (scheduled for January 2011), planning for the Phase I clearance analysis began immediately. Using the Dynamic Onboard Ubiquitous Graphics (DOUG) program, ISAG designed a way to acquire images of the SVS control points on truss segments S1 and S3, the aft facing edge of the S-TRRJ Heat Rejection Subsystem (HRS) radiator, and the three UCCAS latch mechanisms mounted on the zenith face of the S3 truss using the Space Station Remote Manipulator System (SSRMS). To minimize the number of SSRMS movements, the Special Purpose Dexterous Manipulator (SPDM) would be attached to the SSRMS. This would make it possible to park the SPDM in one position and acquire multiple images by changing the viewing orientation of the SPDM body cameras using the pan/tilt units on which they are mounted. Using this implementation concept, ISAG identified four SSRMS

  16. 20 CFR 653.501 - Requirements for accepting and processing clearance orders.

    Science.gov (United States)

    2010-04-01

    ... the job order. (i) No agricultural or food processing order shall be included in job bank listings... clearance any job order seeking workers to perform agricultural or food processing work before reviewing it... order seeking workers to perform agricultural or food processing work into intrastate clearance unless...

  17. 10 CFR 95.21 - Withdrawal of requests for facility security clearance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Withdrawal of requests for facility security clearance. 95.21 Section 95.21 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) FACILITY SECURITY CLEARANCE AND SAFEGUARDING OF NATIONAL SECURITY INFORMATION AND RESTRICTED DATA Physical Security § 95.21 Withdrawal of...

  18. Rapid Treponema pallidum clearance from blood and ulcer samples following single dose benzathine penicillin treatment of early syphilis.

    Science.gov (United States)

    Tipple, Craig; Jones, Rachael; McClure, Myra; Taylor, Graham

    2015-02-01

    Currently, the efficacy of syphilis treatment is measured with anti-lipid antibody tests. These can take months to indicate cure and, as a result, syphilis treatment trials require long periods of follow-up. The causative organism, Treponema pallidum (T. pallidum), is detectable in the infectious lesions of early syphilis using DNA amplification. Bacteraemia can likewise be identified, typically in more active disease. We hypothesise that bacterial clearance from blood and ulcers will predict early the standard serology-measured treatment response and have developed a qPCR assay that could monitor this clearance directly in patients with infectious syphilis. Patients with early syphilis were given an intramuscular dose of benzathine penicillin. To investigate the appropriate sampling timeframe samples of blood and ulcer exudate were collected intensively for T. pallidum DNA (tpp047 gene) and RNA (16S rRNA) quantification. Sampling ended when two consecutive PCRs were negative. Four males were recruited. The mean peak level of T. pallidum DNA was 1626 copies/ml whole blood and the mean clearance half-life was 5.7 hours (std. dev. 0.53). The mean peak of 16S rRNA was 8879 copies/ml whole blood with a clearance half-life of 3.9 hours (std. dev. 0.84). From an ulcer, pre-treatment, 67,400 T. pallidum DNA copies and 7.08 x 107 16S rRNA copies were detected per absorbance strip and the clearance half-lives were 3.2 and 4.1 hours, respectively. Overall, T. pallidum nucleic acids were not detected in any sample collected more than 56 hours (range 20-56) after treatment. All patients achieved serologic cure. In patients with active early syphilis, measuring T. pallidum levels in blood and ulcer exudate may be a useful measure of treatment success in therapeutic trials. These laboratory findings need confirmation on a larger scale and in patients receiving different therapies.

  19. Rapid Treponema pallidum clearance from blood and ulcer samples following single dose benzathine penicillin treatment of early syphilis.

    Directory of Open Access Journals (Sweden)

    Craig Tipple

    2015-02-01

    Full Text Available Currently, the efficacy of syphilis treatment is measured with anti-lipid antibody tests. These can take months to indicate cure and, as a result, syphilis treatment trials require long periods of follow-up. The causative organism, Treponema pallidum (T. pallidum, is detectable in the infectious lesions of early syphilis using DNA amplification. Bacteraemia can likewise be identified, typically in more active disease. We hypothesise that bacterial clearance from blood and ulcers will predict early the standard serology-measured treatment response and have developed a qPCR assay that could monitor this clearance directly in patients with infectious syphilis. Patients with early syphilis were given an intramuscular dose of benzathine penicillin. To investigate the appropriate sampling timeframe samples of blood and ulcer exudate were collected intensively for T. pallidum DNA (tpp047 gene and RNA (16S rRNA quantification. Sampling ended when two consecutive PCRs were negative. Four males were recruited. The mean peak level of T. pallidum DNA was 1626 copies/ml whole blood and the mean clearance half-life was 5.7 hours (std. dev. 0.53. The mean peak of 16S rRNA was 8879 copies/ml whole blood with a clearance half-life of 3.9 hours (std. dev. 0.84. From an ulcer, pre-treatment, 67,400 T. pallidum DNA copies and 7.08 x 107 16S rRNA copies were detected per absorbance strip and the clearance half-lives were 3.2 and 4.1 hours, respectively. Overall, T. pallidum nucleic acids were not detected in any sample collected more than 56 hours (range 20-56 after treatment. All patients achieved serologic cure. In patients with active early syphilis, measuring T. pallidum levels in blood and ulcer exudate may be a useful measure of treatment success in therapeutic trials. These laboratory findings need confirmation on a larger scale and in patients receiving different therapies.

  20. Clearance of insoluble dust from the lower respiratory tract

    Energy Technology Data Exchange (ETDEWEB)

    Morrow, P E; Gibb, F R; Johnson, L

    1964-01-01

    Clearance of tagged heavy metal aerosols (Fe, Hg, Mn, Ba, and U) in female beagles by in vivo counting was assessed. Fecal excretion paralleled lower respiratory tract clearance of Fe. No Fe was found in blood, indicating its biological insolubility. Ultrafiltration tests (an indication of biological solubility) ranked the heavy metals as: Hg, Mn, Fe, and U in order of decreasing solubility. The solubility ratios were remarkably similar to the ratios of inverse biological half-times.

  1. Mechanistic and quantitative insight into cell surface targeted molecular imaging agent design.

    Science.gov (United States)

    Zhang, Liang; Bhatnagar, Sumit; Deschenes, Emily; Thurber, Greg M

    2016-05-05

    Molecular imaging agent design involves simultaneously optimizing multiple probe properties. While several desired characteristics are straightforward, including high affinity and low non-specific background signal, in practice there are quantitative trade-offs between these properties. These include plasma clearance, where fast clearance lowers background signal but can reduce target uptake, and binding, where high affinity compounds sometimes suffer from lower stability or increased non-specific interactions. Further complicating probe development, many of the optimal parameters vary depending on both target tissue and imaging agent properties, making empirical approaches or previous experience difficult to translate. Here, we focus on low molecular weight compounds targeting extracellular receptors, which have some of the highest contrast values for imaging agents. We use a mechanistic approach to provide a quantitative framework for weighing trade-offs between molecules. Our results show that specific target uptake is well-described by quantitative simulations for a variety of targeting agents, whereas non-specific background signal is more difficult to predict. Two in vitro experimental methods for estimating background signal in vivo are compared - non-specific cellular uptake and plasma protein binding. Together, these data provide a quantitative method to guide probe design and focus animal work for more cost-effective and time-efficient development of molecular imaging agents.

  2. Dependence of 'CT clearance' on dosage and time

    International Nuclear Information System (INIS)

    Kaltenborn, H.A.; Klose, K.J.; Dexheimer, C.; Steinijans, V.

    1989-01-01

    The contrast medium dose used in CT renal function analysis corresponds to about 1 ml/kg body weight at a measurement interval of 5 or 10 minutes. In the present study the dependence of 'CT clearance' on dosage and time was examined in 12 healthy subjects. The amount of clearance was directly proportional to the employed contrast medium dose and to the length of the measurement interval. On account of the superior signal-to-noise ratio, the higher dose (1 ml/kg body weight) will continue to be prefered in future. The measurement interval can be limited to 10 minutes. (orig.) [de

  3. Pulmonary epithelial clearance of 99mTc-DTPA after thrombin-induced pulmonary microembolism

    International Nuclear Information System (INIS)

    Cooper, J.A.; Feustel, P.J.; Line, B.R.; Malik, A.B.

    1986-01-01

    We investigated the effect of thrombin-induced pulmonary microembolism on the pulmonary clearance rate of aerosolized 99mTc diethylenetriamine pentaacetic acid (99mTc-DTPA) in awake, chronically prepared sheep. Chest activity was recorded after administration of a 0.44 micron aerosol of 99mTc-DTPA. Decay-corrected data were fit to an exponential and expressed as percent decrease per min (%/min). Sheep were given alpha-thrombin intravenously (80 U/kg for 10 min) 60 min after the aerosol administration. The clearance rate prior to alpha-thrombin was 0.35 +/- 0.05 %/min (mean +/- SEM). During alpha-thrombin administration, the clearance rate increased to 5.84 +/- 0.70 %/min (p less than 0.001 from baseline), but returned to 0.41 +/- 0.06 %/min within 30 min after the end of the thrombin infusion. The increased clearance rate during alpha-thrombin administration was not due to increased lung volume since alpha-thrombin did not change functional residual capacity. Moreover, the clearance rate was unchanged during gamma-thrombin administration, which does not induce coagulation, or during alpha-thrombin challenge in defibrinogenated animals. alpha-thrombin administration in neutrophil-depleted sheep caused a transient increase in DTPA clearance similar to that in control sheep, suggesting that the increase occurred independently of neutrophils. The results indicate that alpha-thrombin causes a large, transient increase in 99mTc-DTPA clearance, which may be the result of increased epithelial permeability. This response is dependent on the activation of intravascular coagulation

  4. Efficient internalization of mesoporous silica particles of different sizes by primary human macrophages without impairment of macrophage clearance of apoptotic or antibody-opsonized target cells

    International Nuclear Information System (INIS)

    Witasp, Erika; Kupferschmidt, Natalia; Bengtsson, Linnea; Hultenby, Kjell; Smedman, Christian; Paulie, Staffan; Garcia-Bennett, Alfonso E.; Fadeel, Bengt

    2009-01-01

    Macrophage recognition and ingestion of apoptotic cell corpses, a process referred to as programmed cell clearance, is of considerable importance for the maintenance of tissue homeostasis and in the resolution of inflammation. Moreover, macrophages are the first line of defense against microorganisms and other foreign materials including particles. However, there is sparse information on the mode of uptake of engineered nanomaterials by primary macrophages. In this study, mesoporous silica particles with cubic pore geometries and covalently fluorescein-grafted particles were synthesized through a novel route, and their interactions with primary human monocyte-derived macrophages were assessed. Efficient and active internalization of mesoporous silica particles of different sizes was observed by transmission electron microscopic and flow cytometric analysis and studies using pharmacological inhibitors suggested that uptake occurred through a process of endocytosis. Moreover, uptake of silica particles was independent of serum factors. The silica particles with very high surface areas due to their porous structure did not impair cell viability or function of macrophages, including the ingestion of different classes of apoptotic or opsonized target cells. The current findings are relevant to the development of mesoporous materials for drug delivery and other biomedical applications.

  5. Numerical Investigation of Pressure Fluctuation Characteristics in a Centrifugal Pump with Variable Axial Clearance

    Directory of Open Access Journals (Sweden)

    Lei Cao

    2016-01-01

    Full Text Available Clearance flows in the sidewall gaps of centrifugal pumps are unsteady as well as main flows in the volute casing and impeller, which may cause vibration and noise, and the corresponding pressure fluctuations are related to the axial clearance size. In this paper, unsteady numerical simulations were conducted to predict the unsteady flows within the entire flow passage of a centrifugal pump operating in the design condition. Pressure fluctuation characteristics in the volute casing, impeller, and sidewall gaps were investigated with three axial clearance sizes. Results show that an axial clearance variation affects the pressure fluctuation characteristics in each flow domain by different degree. The greatest pressure fluctuation occurs at the blade pressure surface and is almost not influenced by the axial clearance variation which has a certainly effect on the pressure fluctuation characteristics around the tongue. The maximum pressure fluctuation amplitude in the sidewall gaps is larger than that in the volute casing, and different spectrum characteristics show up in the three models due to the interaction between the clearance flow and the main flow as well as the rotor-stator interaction. Therefore, clearance flow should be taken into consideration in the hydraulic design of centrifugal pumps.

  6. Glomerular filtration in kidney recipients measured by plasma clearance of 169Yb-DTPA

    International Nuclear Information System (INIS)

    Stribrna, J.; Oppelt, A.; Jirickova, E.; Janata, V.; Kocandrle, V.; Sup, I.; Woller, P.; Franke, W.G.

    1986-01-01

    Values of 169 Yb-DTPA clearance (C DTPA ) calculated after a single injection were compared in 26 recipients of kidneys with renal clearance of inulin (C in ), polyfructosan S (C pf ) and creatinine (C cr ). In 21 patients the examinations were made simultaneously, in 5 patients C DTPA was measured within a short interval after the examination of renal clearance. The mean C DTPA values did not significantly differ from C cr but were significantly higher (p in and C pf (by 33% on average). Investigation of changes in C DTPA as compared with C in and C pf showed no significant difference in glomerular filtration (GF). This was measured using inulin and polyfructosan. The results showed that the differing molecular weight of inulin and polyfructosan S had no detectable effect on the GF of kidney recipients. The plasma clearance of 169 Yb-DTPA similarly to C cr overestimates the GF measured by inulin and polyfructosan clearance. (author)

  7. A computer program for unilateral renal clearance calculation by a modified Oberhausen method

    International Nuclear Information System (INIS)

    Brueggemann, G.

    1980-01-01

    A FORTAN program is presented which, on the basis of data obtained with NUKLEOPAN M, calculates the glomerular filtration rate with sup(99m)Tc-DTPA, the unilateral effective renal plasma flow with 131 I-hippuran, and the parameters for describing the isotope rephrogram (ING) with 131 I-hippuran. The results are calculated fully automatically upon entry of the data, and the results are processed and printed out. The theoretical fundamentals of ING and whole-body clearance calculation are presented as well as the methods available for unilateral clearance calculation, and the FORTAN program is described in detail. The standard values of the method are documented, as well as a comparative gamma camera study of 48 patients in order to determine the accuracy of unilateral imaging with the NUKLEOPAN M instrument, a comparison of unilateral clearances by the Oberhausen and Taplin methods, and a comparison between 7/17' plasma clearance and whole-body clearance. Problems and findings of the method are discussed. (orig./MG) [de

  8. Clearance, a powerful tool in optimizing the volume of radioactive wastes

    International Nuclear Information System (INIS)

    Blommaert, W.; Teunckens, L.

    1997-01-01

    In the framework its activities in decommissioning nuclear installations, Belgoprocess applies the clearance practice in optimizing the volume of radioactive wastes. The applied clearance methodology is discussed with special emphasis to different types of materials and to the associated measurements. Four practical cases are elaborated, dealing with the decommissioning and decontamination of two small buildings up to green field conditions, the unconditional release of large quantities of slightly contaminated active carbon, the melting and clearance of stainless steel fuel racks and of aluminium heat exchangers. The attention is drawn on practical problems associated with sampling and measurement strategies, in relation to the proposed low limits for unconditional release. (author)

  9. A review and comparison of international exemption and clearance levels

    International Nuclear Information System (INIS)

    Cooper, J.R.; Mobbs, S.F.

    1997-01-01

    The publication of new European Basic Safety Standards by the European Commission and of new International Basic Safety Standards by the IAEA together with other international agencies, has led to increased interest in the application of the concepts of exemption and clearance. This paper discusses the derivation of radionuclide-specific exemption and clearance values for application in various areas of the regulation of radioactive materials. (author)

  10. Clearance measurements on activated parts of accelerators by combined methods; Verfahrenskombinierte Freigabemessung aktivierter Beschleunigerteile

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, S.; Friedemann, S. [VKTA, Dresden (Germany); Enghardt, W. [Technische Univ. Dresden (Germany). OncoRay

    2016-07-01

    The process of clearance of radioactive materials according to paragraph 29 StrlSchV contents the comparison of activity to mass and surface of the material. To avoid a borderless assessment of activity of activation it is often necessary to use combined measurement methods: For clearance of collimators of a medical proton accelerator (energy range up to 200 MeV) it needs to know the nuclide composition. The energetical and geometrical calibration was fixed by experiments. The clearance based on measurements of activity distribution, gammaspectroscopy verification of nuclide composition and gamma-counting detectors. Parts of medical electron-accelerators achieved its clearance by combination of abovementioned methods and in-situ-gammaspectroscopy. Activated und contaminated lead stones achieved its clearance by measurements of fluence, laboratory evaluation of samples, in-situ-gammaspectroscopy and wipe tests.

  11. Cancer nanomedicine: a review of recent success in drug delivery.

    Science.gov (United States)

    Tran, Stephanie; DeGiovanni, Peter-Joseph; Piel, Brandon; Rai, Prakash

    2017-12-11

    Cancer continues to be one of the most difficult global healthcare problems. Although there is a large library of drugs that can be used in cancer treatment, the problem is selectively killing all the cancer cells while reducing collateral toxicity to healthy cells. There are several biological barriers to effective drug delivery in cancer such as renal, hepatic, or immune clearance. Nanoparticles loaded with drugs can be designed to overcome these biological barriers to improve efficacy while reducing morbidity. Nanomedicine has ushered in a new era for drug delivery by improving the therapeutic indices of the active pharmaceutical ingredients engineered within nanoparticles. First generation nanomedicines have received widespread clinical approval over the past two decades, from Doxil ® (liposomal doxorubicin) in 1995 to Onivyde ® (liposomal irinotecan) in 2015. This review highlights the biological barriers to effective drug delivery in cancer, emphasizing the need for nanoparticles for improving therapeutic outcomes. A summary of different nanoparticles used for drug delivery applications in cancer are presented. The review summarizes recent successes in cancer nanomedicine in the clinic. The clinical trials of Onivyde leading to its approval in 2015 by the Food and Drug Adminstration are highlighted as a case study in the recent clinical success of nanomedicine against cancer. Next generation nanomedicines need to be better targeted to specifically destroy cancerous tissue, but face several obstacles in their clinical development, including identification of appropriate biomarkers to target, scale-up of synthesis, and reproducible characterization. These hurdles need to be overcome through multidisciplinary collaborations across academia, pharmaceutical industry, and regulatory agencies in order to achieve the goal of eradicating cancer. This review discusses the current use of clinically approved nanomedicines, the investigation of nanomedicines in clinical

  12. Comparison of gas clearance and radioactive microspheres for pancreatic blood flow measurement

    International Nuclear Information System (INIS)

    DeMar, A.R.; Graham, L.S.; Lake, R.; Fink, A.S.

    1989-01-01

    Measurement of pancreatic blood flow (PBF) is technically demanding. Although radiolabeled microspheres are considered the gold standard for PBF assessment, they have practical limitations. In the current study, H 2 and xenon-133 gas clearance techniques were adapted to PBF measurement and compared to radiolabeled microsphere techniques. Simultaneous measurements of PBF were made using either hydrogen or xenon gas washout and radiolabeled microspheres. Measurements were made under basal, vasoconstricted (vasopressin 2U i.v. or nicotine 4 micrograms/kg/h) and stimulated (secretin 125 ng/kg/h or 2 U/kg i.v.) conditions (random order). Mean PBF was 26.9 +/- 5.3, 50.5 +/- 2.3 and 27.6 +/- 5.2 ml/min/100 g basally, 36.9 +/- 8.0, 90.1 +/- 18.9, and 81.7 +/- 14.5 ml/min/100 g in the stimulated state, and 24.2 +/- 7.8, 25.0 +/- 3.5, and 14.9 +/- 7.5 ml/min/100 g in the vasoconstricted state for hydrogen gas clearance, xenon gas clearance, and radiolabeled microspheres, respectively. The H 2 clearance technique resulted in tissue trauma, was complicated by frequent electrode displacement, and correlated poorly (r2 = 0.36, p greater than 0.05) with microsphere values. In contrast, xenon clearance measurement had no apparent effect on the pancreas and correlated well (r2 = 0.83, p less than 0.01) with microsphere data. We conclude that xenon clearance offers an attractive, validated alternative to radiolabeled microspheres for measuring pancreatic blood flow

  13. Long-term clearance from small airways in subjects with ciliary dysfunction

    Directory of Open Access Journals (Sweden)

    Hjelte Lena

    2006-05-01

    Full Text Available Abstract The objective of this study was to investigate if long-term clearance from small airways is dependent on normal ciliary function. Six young adults with primary ciliary dyskinesia (PCD inhaled 111 Indium labelled Teflon particles of 4.2 μm geometric and 6.2 μm aerodynamic diameter with an extremely slow inhalation flow, 0.05 L/s. The inhalation method deposits particles mainly in the small conducting airways. Lung retention was measured immediately after inhalation and at four occasions up to 21 days after inhalation. Results were compared with data from ten healthy controls. For additional comparison three of the PCD subjects also inhaled the test particles with normal inhalation flow, 0.5 L/s, providing a more central deposition. The lung retention at 24 h in % of lung deposition (Ret24 was higher (p 24 with slow inhalation flow was 73.9 ± 1.9 % compared to 68.9 ± 7.5 % with normal inhalation flow in the three PCD subjects exposed twice. During day 7–21 the three PCD subjects exposed twice cleared 9 % with normal flow, probably representing predominantly alveolar clearance, compared to 19 % with slow inhalation flow, probably representing mainly small airway clearance. This study shows that despite ciliary dysfunction, clearance continues in the small airways beyond 24 h. There are apparently additional clearance mechanisms present in the small airways.

  14. APPLICATION OF DSM IN OBSTACLE CLEARANCE SURVEYING OF AERODROME

    Directory of Open Access Journals (Sweden)

    X. Qiao

    2016-06-01

    Full Text Available Compared to the wide use of digital elevation model (DEM, digital surface model (DSM receives less attention because that it is composed by not only terrain surface, but also vegetations and man-made objects which are usually regarded as useless information. Nevertheless, these objects are useful for the identification of obstacles around an aerodrome. The primary objective of the study was to determine the applicability of DSM in obstacle clearance surveying of aerodrome. According to the requirements of obstacle clearance surveying at QT airport, aerial and satellite imagery were used to generate DSM, by means of photogrammetry, which was spatially analyzed with the hypothetical 3D obstacle limitation surfaces (OLS to identify the potential obstacles. Field surveying was then carried out to retrieve the accurate horizontal position and height of the obstacles. The results proved that the application of DSM could make considerable improvement in the efficiency of obstacle clearance surveying of aerodrome.

  15. Effects of sustained exercise on pulmonary clearance of aerosolized 99mTc-DTPA

    International Nuclear Information System (INIS)

    Lorino, A.M.; Meignan, M.; Bouissou, P.; Atlan, G.

    1989-01-01

    The effects of intensive prolonged exercise on the pulmonary clearance rate of aerosolized 99m Tc-labeled diethylenetriaminepentaacetate ( 99m Tc-DTPA) and pulmonary mechanics were studied in seven healthy nonsmoking volunteers. 99m Tc-DTPA clearance and pulmonary mechanics (lung volumes and compliance) were assessed before and after 75 min of constant-load exercise performed on a treadmill, corresponding to 75% of maximal O 2 uptake. Because both clearance measurements were made in similar conditions of pulmonary blood flow, respiratory rate, and tidal volume, changes in clearance rate can be assumed to represent changes of alveolar epithelial permeability. After exercise, total, apical, and basal clearance were significantly increased (P less than 0.01, 0.05, and 0.05, respectively) and the increases in total clearance and tidal volume observed during exercise were significantly correlated (P less than 0.05). In contrast, no significant change was found in pulmonary mechanics. These results show that prolonged intensive exercise induces an increase in epithelial permeability, which appears to be related to the mechanical effects of sustained increased ventilation. Because no change was evidenced in pulmonary volumes or in lung elasticity, our results suggest that this increase may result from alteration of the intercellular tight junctions rather than from a surfactant deficiency

  16. Higher Midazolam Clearance in Obese Adolescents Compared with Morbidly Obese Adults

    NARCIS (Netherlands)

    Rongen, van A.; Brill, M.J.E.; Vaughns, J.D.; Välitalo, P.A.J.; Dongen, van E.P.A.; Ramshorst, van B.; Barrett, J.S.; Anker, van den J.N.; Knibbe, C.A.J.

    2017-01-01

    The clearance of cytochrome P450 (CYP) 3A substrates is reported to be reduced with lower age, inflammation and obesity. As it is unknown what the overall influence is of these factors in the case of obese adolescents vs. morbidly obese adults, we studied covariates influencing the clearance of the

  17. Characterization and Clearance of m/s Sigyn

    International Nuclear Information System (INIS)

    Jiselmark, Jonatan; Vreede, Patrick

    2016-01-01

    M/s Sigyn was a 2044 ton ship that transported contaminated material between 1982 and 2013. Most of the transports were with spent nuclear fuel between Swedish nuclear power plants and the Swedish fuel repository, Clab. In addition to spent fuel, m/s Sigyn also transported big contaminated components, from nuclear power plants in Europe, to Studsvik for analysis or decontamination and melting. She also transported components from Swedish nuclear power plants to final disposal of short lived waste, SFR. Even though all transported items have been cleaned, checked and wrapped with plastics, some activity ended up as contamination onboard. In December 2013 it was decided that m/s Sigyn was subject for decommissioning due to her age. This Paper describes the method in which the activity onboard m/s Sigyn was characterized and clearance levels were calculated. This method for radiological characterization and clearance has recently been developed in Sweden, the method is efficient in that it does not need a big pre characterization survey. Only the nuclide distribution and history of the object, is needed to start the final survey. In the future there will be further development of the method, making it possible to reduce the number of measurements even more. This will further optimize the method and reduce the cost for final surveys and clearance. (authors)

  18. 48 CFR 52.216-17 - Incentive Price Revision-Successive Targets.

    Science.gov (United States)

    2010-10-01

    ... incurred plus an estimate of costs to complete performance, in the format of table 15-2, FAR 15.408 (or in... percents] of the total initial target cost. (3) If the total firm target cost plus the total firm target... is less than the total firm target cost, the adjustment is the total firm target profit, plus...

  19. A stochastic approach to the derivation of exemption and clearance levels

    International Nuclear Information System (INIS)

    Deckert, A.

    1997-01-01

    Deciding what clearance levels are appropriate for a particular waste stream inherently involves a number of uncertainties. Some of these uncertainties can be quantified using stochastic modeling techniques, which can aid the process of decision making. In this presentation the German approach to dealing with the uncertainties involved in setting clearance levels is addressed. (author)

  20. Improving accuracy of ET measurement of LISS nozzle to calandria tube clearance

    International Nuclear Information System (INIS)

    Craig, S.T.; Krause, T.W.; Schankula, J.J.

    2006-01-01

    The AECL Fuel Channel Inspection System (AFCIS) has been used in an in-reactor field trial to successfully measure the clearance between Liquid Injection Shutdown System (LISS) nozzles and calandria tubes. Each measurement over the full length of a channel added only 15 minutes to the on-channel inspection time. No changes were required to the inspection heads. The only equipment changes made were the addition of a Remote Field Eddy Current (RFEC) module to the eddy current instrument, and minor wiring changes, at the instrument, to achieve a RFEC configuration. With the experience gained from the field trial, factors potentially limiting accuracy were identified. These, and other factors, were investigated and are discussed herein. The RFEC probe is delivered inside the pressure tube. Magnetic fields from the RFEC probe extend through the conducting walls of the pressure tube and calandria tube to interact with the LISS nozzle. Data acquired during the field trial showed the LISS nozzle signal is distinct and the signal-to-noise ratio is very favourable. Nevertheless, comparison of the RFEC measurements to a visual examination, made during the same outage, had the RFEC method underestimating the clearance by 2.5 mm on average. By way of laboratory tests, the following factors were investigated as potential sources of error: resistivity and geometry of LISS nozzle reference/calibration pieces, pressure-tube wall thickness, diameter and resistivity variations, pressure-tube to calandria-tube gap, and radial offsets of the probe within the pressure-tube. The sensitivity to these various noise sources was established. A model, based on fundamental electromagnetic principles, was developed and was used to normalize the effects of LISS nozzle conductivity and geometry. This enabled compensation for various sources of error, and made it possible to produce a correction factor for the field trial data, reducing the average difference from the visual inspection of LISS

  1. Immunotherapy for the treatment of Alzheimer's disease: amyloid-β or tau, which is the right target?

    Directory of Open Access Journals (Sweden)

    Castillo-Carranza DL

    2013-12-01

    Full Text Available Diana L Castillo-Carranza,1,2 Marcos J Guerrero-Muñoz,1,2 Rakez Kayed1–31Mitchell Center for Neurodegenerative Diseases, 2Departments of Neurology, Neuroscience, and Cell Biology, 3Sealy Center for Vaccine Development, University of Texas Medical Branch, Galveston, TX, USAAbstract: Alzheimer's disease (AD is characterized by the presence of amyloid plaques composed mainly of amyloid-β (Aβ protein. Overproduction or slow clearance of Aβ initiates a cascade of pathologic events that may lead to formation of neurofibrillary tangles, neuronal cell death, and dementia. Although immunotherapy in animal models has been demonstrated to be successful at removing plaques or prefibrillar forms of Aβ, clinical trials have yielded disappointing results. The lack of substantial cognitive improvement obtained by targeting Aβ raises the question of whether or not this is the correct target. Another important pathologic process in the AD brain is tau aggregation, which seems to become independent once initiated. Recent studies targeting tau in AD mouse models have displayed evidence of cognitive improvement, providing a novel therapeutic approach for the treatment of AD. In this review, we describe new advances in immunotherapy targeting Aβ peptide and tau protein, as well as future directions.Keywords: immunotherapy, Alzheimer's disease, β-amyloid, tau

  2. Modelling of Outer and Inner Film Oil Pressure for Floating Ring Bearing Clearance in Turbochargers

    International Nuclear Information System (INIS)

    Zhang Hao; Shi Zhanqun; Gu Fengshou; Ball, Andrew

    2011-01-01

    Floating ring bearing is widely used in turbochargers to undertake the extreme condition of high rotating speed and high operating temperature. It is also the most concerned by the designers and users alike due to its high failure rate and high maintenance cost. Any little clearance change may result in oil leakage, which in turn cause blue smoke or black smoke according to leakage types. However, there is no condition monitoring of this bearing because it is almost impossible to measure the clearance especially the inner clearance, in which the inner oil film directly bears the high speed rotation. In stead of measuring clearance directly, this paper has proposed a method that uses film pressure as a measure to monitor the bearing clearance and its variation. A non-linear mathematical model is developed by using Reynolds equations with non-linear oil film pressure. A full description of the outer and inner film is provided along both axial and radial directions. A numerical simulation is immediately carried out. Variable clearance changes are investigated using the mathematical model. Results show the relationship between clearance and film pressure.

  3. Comparison between total and renal plasma clearance of [51Cr]EDTA

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Roedbro, P.

    1976-01-01

    The total plasma (E 1 ) and renal plasma (E 2 ) clearances of [ 51 Cr]EDTA were measured simultaneously in 40 patients with a wide range of renal function. The regression equation was E 1 = 0.997E 2 + 4.1; the slope of the regression line was not significantly different from 1.00, and the intercept differed significantly from zero. The results suggest that [ 51 Cr]EDTA has a significant extrarenal clearance of approximately 4 ml/min, independent of renal function. The data are used to correct the total [ 51 Cr]EDTA plasma clearance, measured by a simplified method, to yield a rapid, accurate and precise measurement of glomerular filtration rate for routine clinical use. (Auth.)

  4. Effective usage of a clearance check to avoid a collision in Gamma Knife Perfexion radiosurgery with the Leksell skull frame

    International Nuclear Information System (INIS)

    Nakazawa, Hisato; Komori, Masataka; Tsugawa, Takahiko; Hagiwara, Masahiro; Hashizume, Chisa; Kobayashi, Tatsuya; Mori, Yoshimasa; Shibamoto, Yuta

    2014-01-01

    Skull frame attachment is one of the most significant issues with Gamma Knife radiosurgery. Because of the potential for suffering by patients, careful control of the frame position is required to avoid circumstances such as collision between the frame or the patient's head and the collimator helmet, and inaccessible target coordinates. This study sought to develop a simulation method to find the appropriate frame location on the patient's head by retrospective analysis of treatment plans for brain metastasis cases. To validate the accuracy of the collision warning, we compared the collision distance calculated using Leksell Gamma Plan (LGP) with actual measured distances. We then investigated isocenter coordinates in near-collision cases using data from 844 previously treated patients and created a clearance map by superimposing them on CT images for just the frame, post and stereotactic fiducial box. The differences in distance between the simulation in LGP and the measured values were <1.0 mm. In 177 patients, 213 lesions and 461 isocenters, there was a warning of one possible collision. The clearance map was helpful for simulating appropriate skull frame placement. The clearance simulation eliminates the psychological stress associated with potential collisions, and enables more comfortable treatment for the patient. (author)

  5. Traffic Incident Clearance Time and Arrival Time Prediction Based on Hazard Models

    Directory of Open Access Journals (Sweden)

    Yang beibei Ji

    2014-01-01

    Full Text Available Accurate prediction of incident duration is not only important information of Traffic Incident Management System, but also an effective input for travel time prediction. In this paper, the hazard based prediction models are developed for both incident clearance time and arrival time. The data are obtained from the Queensland Department of Transport and Main Roads’ STREAMS Incident Management System (SIMS for one year ending in November 2010. The best fitting distributions are drawn for both clearance and arrival time for 3 types of incident: crash, stationary vehicle, and hazard. The results show that Gamma, Log-logistic, and Weibull are the best fit for crash, stationary vehicle, and hazard incident, respectively. The obvious impact factors are given for crash clearance time and arrival time. The quantitative influences for crash and hazard incident are presented for both clearance and arrival. The model accuracy is analyzed at the end.

  6. Production of plastic scintillation survey meter for clearance verification measurement

    International Nuclear Information System (INIS)

    Tachibana, Mitsuo; Shiraishi, Kunio; Ishigami, Tsutomu; Tomii, Hiroyuki

    2008-03-01

    In the Nuclear Science Research Institute, the decommissioning of various nuclear facilities is carried out according to the plan for meeting the midterm goal of the Japan Atomic Energy Agency (JAEA). An increase in the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas will be expected along with the dismantlement of nuclear facilities in the future. The radiation measurement for releasing controlled areas has been carried out in small-scale nuclear facilities including the JPDR (Japan Power Demonstration Reactor). However, the radiation measurement with an existing measuring device was difficult in effects of radiation from radioactive materials that remains in buried piping. On the other hand, there is no experience that the clearance verification measurement is executed in the JAEA. The generation of a large amount of clearance object will be expected along with the decommissioning of the nuclear facilities in the future. The plastic scintillation survey meter (hereafter, 'PL measuring device') was produced to apply to the clearance verification measurement and the radiation measurement for releasing controlled areas. The basic characteristic test and the actual test were confirmed using the PL measuring device. As a result of these tests, it was found that the evaluation value of radioactivity with the PL measuring device was accuracy equal with the existing measuring device. The PL measuring device has feature of the existing measuring device with a light weight and easy operability. The PL measuring device can correct the gamma ray too. The PL measuring device is effective to the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas. (author)

  7. [Airway clearance techniques in chronic obstructive pulmonary syndrome : 2011 update].

    Science.gov (United States)

    Opdekamp, C

    2011-09-01

    For many years the airway clearance techniques used in chest physical therapy were assimilated with the singular technique of postural drainage, percussions and vibrations. However the side effects and counter indications and the lack of scientific proof regarding this technique have forced reflection and development of other techniques more comfortable and without deleterious effects. If all these techniques show a high efficiency in terms of improved mucociliary clearance, the literature is unanimous on how little effect these techniques have in the short and the long-term with regards to lung function and arterial blood gases. In view of the scientific literature, it is clear that the airway clearance techniques don't have the same recognition concerning their efficiency in all obstructive pulmonary diseases. As the cornerstone in the management of cystic fibrosis, the efficiency of the bronchial hygiene techniques are in general poorly documented in the management of the non-cystic fibrosis bronchiectasis, bronchitis or emphysema. The use of the chest physical therapy seems more to do with the interpretation of the imagery and symptomatology. The airway clearance techniques should be individualised according to symptoms, the amount of expectorated mucus and the objectives signs of secretions retention or subjective signs of difficulty expectorating secretions with progression of the disease.

  8. Factors affecting lower calyceal stone clearance after Extracorporeal shock wave lithotripsy

    Directory of Open Access Journals (Sweden)

    S. Azab

    2013-03-01

    Conclusions: There is no statistically significant effect of stone size, anatomy of the lower calyx and BMI on stone clearance after ESWL of lower calyceal stones. However, small stone size (≤2 cm, a shorter and wider infundibulum and a larger lower-pole infundibulopelvic angle seem to promote a more rapid and more complete stone clearance.

  9. Chromium-51-EDTA clearance in adults with a single-plasma sample.

    Science.gov (United States)

    Mårtensson, J; Groth, S; Rehling, M; Gref, M

    1998-12-01

    In 1996, a committee on renal clearance recommended a mean sojourn time-based methodology for single-sample determination of plasma clearance of 99mTc-diethylenetriamine pentaacetic acid (DTPA) to be used on adults if the patient's glomerular filtration rate (GFR) is suspected to be >30 ml/min. The main purpose of this study was to derive a mean sojourn time-based formula for calculation of 51Cr-ethylenediamine tetraacetic acid (EDTA) clearance in adults. Two groups of patients with 51Cr-EDTA clearance (Cl) between 16 and 172 ml/min were studied. In Group I (n = 46), reference Cl was determined as a multiplasma sample, single-injection method (ClSM). Sixteen blood samples were drawn from 0 until 5 hr after a single intravenous injection of 51Cr-EDTA. In Group II (n = 1046), reference Cl was determined by the Brøchner-Mortensen four-sample clearance method (ClBM). The plasma time-activity curves of Group I were used to derive two mean sojourn time-based formulas (Formulas 1 and 2) for calculation of a single-sample clearance. Formula 1 was derived from the entire time-activity curve, whereas the derivation of Formula 2 used only the final slope of the time-activity curve. The accuracy of the two formulas and the Christensen and Groth 99mTc-DTPA formula was tested on Group II. Chromium-51-EDTA Cl calculated by Formula 1 was almost identical to the Cl calculated by the reference Cl method (r = 0.982; SDdiff = 5.82 ml/min). Both 51Cr-EDTA Cl calculated by Formula 2 and by the 99mTc-DTPA formula showed close correlation with the reference method (r = 0.976, r = 0.985, respectively) but systematically overestimated GFR for the whole range of clearance values by 3.5 and 3.2 ml/min (ptime methodology. The determination is marginally more accurate (ptime-activity curve than from only the final slope. The single-sample formula derived for determination of 99mTc-DTPA Cl tends slightly to overestimate GFR if used to calculate 51Cr-EDTA Cl.

  10. Clearance of material with negligible levels of radioactivity based on the amended German radiation protection ordinance

    International Nuclear Information System (INIS)

    Schaller, G.; Bayer, A.

    2002-01-01

    For the first time the modalities for the clearance of relevant materials have been laid down in the amended Radiation Protection Ordinance in a comprehensive form. A distinction is made between unconditional clearance and cases of clearance in which disposal, recycling, and re-use is prescribed. The focus of attention in the case of unconditional clearance consists in special consideration of large volumes of building rubble and excavated soil. Material can only be released from supervision under the Atomic Energy Act, when the radiation-related risk, and correspondingly, also the dose from material issued with clearance, are at negligible levels. In order to facilitate the practical application of clearance, values have been derived on the basis of scenarios which cover all radiation exposures which can reasonably be considered. (orig.) [de

  11. Qualitative and quantitative intravaginal targeting: key to anti-HIV-1 microbicide delivery from test tube to in vivo success.

    Science.gov (United States)

    Pillay, Viness; Mashingaidze, Felix; Choonara, Yahya E; Du Toit, Lisa C; Buchmann, Eckhart; Maharaj, Vinesh; Ndesendo, Valence M K; Kumar, Pradeep

    2012-06-01

    The past decade has seen several effective anti-HIV-1 agent discoveries, yet microbicides continue to disappoint clinically. Our review expounds the view that unsatisfactory microbicide failures may be a result of inefficient delivery systems employed. We hereby propose a thorough scientific qualitative and quantitative investigation of important aspects involved in HIV-1 transmission as a prerequisite for microbicide delivery. Intravaginal targeting of HIV-1 increases the chances of microbicide success, wherein vaginal microenvironmental factors including pH should be maintained at HIV-1 prohibitive acidic levels simultaneously to ward off other sexually transmitted diseases, which compromise vaginal epithelial barrier properties. Furthermore, choice of receptors to target both on HIV-1 and on target cells is vital in deterring transmission. Appropriate modeling of virus-target cell interactions as well as targeting early stages of the HIV-1 infection accompanied by computation and delivery of appropriate microbicide quantities could revolutionize microbicide research, ultimately delivering a female-controlled HIV-1 prevention modality appropriately. Copyright © 2012 Wiley Periodicals, Inc.

  12. Transplacental clearance and blood flows of bovine gravid uterus at several stages of gestation

    International Nuclear Information System (INIS)

    Reynolds, L.P.; Ferrell, C.L.

    1987-01-01

    Rates of uterine and umbilical blood flows and transplacental clearance of deuterium oxide (D 2 O) were determined for cows on 137 +/- 1.0 (SE, n = 9), 180 +/- 0.5 (n = 8), 226 +/- 0.4 (n = 9), and 250 +/- 1.8 (n = 5) days of gestation. From days 137 to 250, rates increased 4.5-fold for uterine blood flow, 21-fold for umbilical blood flow, and 14-fold for clearance of D 2 O. Changes in rates of umbilical blood flow and D 2 O clearance paralleled increased rates of fetal growth and metabolism, which have previously been reported to occur during the last half of gestation. The regressions of D 2 O clearance on uterine and umbilical blood flows were significant (P less than 0.01) and explained 94-99% of the variation in placental clearance of D 2 O. Because the rate of D 2 O clearance was always less than that of uterine and umbilical blood flows, and because a relatively simple statistical model explained most of the variation in clearance, it was suggested that a concurrent or countercurrent arrangement of maternal and fetal placental microvasculatures is not adequate to explain clearance of highly diffusable substances across the bovine placenta. In addition, a placental exchange diagram of the data showed the existence of severe uneven distribution of maternal and fetal placental blood flows and/or significant shunting of maternal and fetal placental flows away from areas of exchange. Taken together, these data indicate that the placenta of the cow, like those of the sheep and goat, represents a relatively inefficient system of transplacental exchange

  13. Limitations of regional myocardial thallium clearance for identification of disease in individual coronary arteries

    International Nuclear Information System (INIS)

    Becker, L.C.; Rogers, W.J. Jr.; Links, J.M.; Corn, C.

    1989-01-01

    The purpose of this study was to critically evaluate the usefulness of postexercise regional myocardial thallium-201 clearance for identifying disease in individual coronary arteries. Exercise and redistribution planar imaging studies were performed in 114 subjects, including 19 normal volunteers and 95 patients undergoing cardiac catheterization (70 with and 25 without greater than or equal to 50% narrowing in one or more coronary arteries). Thallium clearance was measured from predefined myocardial regions corresponding to the left anterior descending, left circumflex and right coronary arteries and was expressed as the percent decrease in activity at 4 h, assuming monoexponential clearance. In regions perfused by a normal or insignificantly diseased coronary artery, mean 4 h clearance was 58.9 +/- 9.4% for normal volunteers, 43.1 +/- 15.5% for catheterized patients without coronary artery disease and 36.3 +/- 24.9% for catheterized patients with coronary artery disease (p less than 0.001 patients with coronary artery disease versus normal volunteers). Clearance from normal regions was significantly associated with two measures of exercise performance: percent of predicted maximal heart rate achieved (r = 0.49) and exercise duration (r = 0.35). In regions perfused by a stenotic coronary artery, mean clearance was lower (31.1 +/- 19.8%) but was not significantly different from that in normal regions in the same patients. Clearance from diseased regions was also associated with maximal exercise heart rate (r = 0.28) and exercise duration (r = 0.41), but not with percent coronary artery stenosis (r = 0.02). After taking exercise performance into account, the number of diseased vessels or the presence or absence of disease in a given vessel had little influence on regional thallium clearance

  14. Small solute clearance from the lungs of patients with cardiogenic and noncardiogenic pulmonary edema

    International Nuclear Information System (INIS)

    Mason, G.R.; Effros, R.M.; Uszler, J.M.; Mena, I.

    1985-01-01

    The regional clearance of /sup 99m/Tc-diethylenetriamine penta-acetate from the lungs was measured in 14 patients with noncardiogenic pulmonary edema, six patients with acute pulmonary edema secondary to heart failure, and 29 normal subjects. The radionuclide was delivered in an aerosol which was inhaled for 120 seconds, and the subsequent decline of radioactivity from the lungs was monitored for seven minutes over each of six peripheral regions of interest with a computerized scintillation camera. The average /sup 99m/Tc-DTPA clearance of these regions was accelerated above the 98 percent confidence limits in all but three of the patients with noncardiogenic edema. The mean clearance value in this group of patients was significantly greater than those in normal subjects or patients with cardiogenic pulmonary edema. Clearances returned toward normal in each of seven subjects who improved clinically. Only one of the patients with cardiogenic pulmonary edema had an elevated average clearance rate, and the mean clearance for this population was not statistically greater than normal. This procedure appears to detect increased epithelial permeability caused by lung injury and may help distinguish between cardiogenic and noncardiogenic pulmonary edema

  15. Waste-clearance strategy for DOE waste processed at commercial facilities

    International Nuclear Information System (INIS)

    Chen, S.Y.; Pfingston, M.; LePoire, D.

    1996-01-01

    In May 1991, a moratorium was issued on shipping potentially mixed waste from DOE facilities nationwide to commercial treatment, storage, and disposal facilities. A potential waste-clearance strategy was developed to address the DOE mixed-waste moratorium issues, which had resulted from a lack of exisitng volume contamination regulations. This strategy also has important potential applications for establishing site clearance limits that ensure worker and public risks remain well below regulatory limits

  16. Plasma clearance of noradrenaline does not change with age in normal subjects

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Larsen, S

    1985-01-01

    Noradrenaline kinetics (plasma concentrations, plasma clearance and appearance rates) were investigated in seven elderly healthy subjects and in six young healthy subjects. Forearm venous plasma noradrenaline concentrations were higher in the elderly subjects compared with the young subjects. Pla....... Plasma clearance of noradrenaline was identical in the two groups. The increase in plasma noradrenaline concentration, with age, probably reflects an increased sympathetic nervous activity.......Noradrenaline kinetics (plasma concentrations, plasma clearance and appearance rates) were investigated in seven elderly healthy subjects and in six young healthy subjects. Forearm venous plasma noradrenaline concentrations were higher in the elderly subjects compared with the young subjects...

  17. The kidneys play a central role in the clearance of rhGH in rats

    DEFF Research Database (Denmark)

    Vestergaard, Bill; Thygesen, Peter; Kreilgaard, Mads

    2016-01-01

    at treatment of patients with growth hormone disorders. The purpose of this study was to investigate the relative importance of the kidneys in the clearance of rhGH. The study employed a newly validated nephrectomy rat model and a population based pharmacokinetic approach to assess renal clearance of rh...... that renal clearance plays a pivotal role in the elimination of rhGH in rats....

  18. A novel clinically translatable fluorescent nanoparticle for targeted molecular imaging of tumors in living subjects.

    Science.gov (United States)

    Gao, Jinhao; Chen, Kai; Luong, Richard; Bouley, Donna M; Mao, Hua; Qiao, Tiecheng; Gambhir, Sanjiv S; Cheng, Zhen

    2012-01-11

    The use of quantum dots (QDs) in biomedical research has grown tremendously, yet successful examples of clinical applications are absent due to many clinical concerns. Here, we report on a new type of stable and biocompatible dendron-coated InP/ZnS core/shell QD as a clinically translatable nanoprobe for molecular imaging applications. The QDs (QD710-Dendron) were demonstrated to hold several significant features: near-infrared (NIR) emission, high stability in biological media, suitable size with possible renal clearance, and ability of extravasation. More importantly, a pilot mouse toxicity study confirmed that QD710-Dendron lacks significant toxicity at the doses tested. The acute tumor uptake of QD710-Dendron resulted in good contrast from the surrounding nontumorous tissues, indicating the possibility of passive targeting of the QDs. The highly specific targeting of QD710-Dendron-RGD(2) to integrin α(v)β(3)-positive tumor cells resulted in high tumor uptake and long retention of the nanoprobe at tumor sites. In summary, QD710-Dendron and RGD-modified nanoparticles demonstrate small size, high stability, biocompatibility, favorable in vivo pharmacokinetics, and successful tumor imaging properties. These features satisfy the requirements for clinical translation and should promote efforts to further investigate the possibility of using QD710-Dendron-based nanoprobes in the clinical setting in the near future. © 2011 American Chemical Society

  19. The tribological behaviour of different clearance MOM hip joints with lubricants of physiological viscosities.

    Science.gov (United States)

    Hu, X Q; Wood, R J K; Taylor, A; Tuke, M A

    2011-11-01

    Clearance is one of the most influential parameters on the tribological performance of metal-on-metal (MOM) hip joints and its selection is a subject of considerable debate. The objective of this paper is to study the lubrication behaviour of different clearances for MOM hip joints within the range of human physiological and pathological fluid viscosities. The frictional torques developed by MOM hip joints with a 50 mm diameter were measured for both virgin surfaces and during a wear simulator test. Joints were manufactured with three different diametral clearances: 20, 100, and 200 microm. The fluid used for the friction measurements which contained different ratios of 25 percent newborn calf serum and carboxymethyl cellulose (CMC) with the obtained viscosities values ranging from 0.001 to 0.71 Pa s. The obtained results indicate that the frictional torque for the 20 microm clearance joint remains high over the whole range of the viscosity values. The frictional torque of the 100 microm clearance joint was low for the very low viscosity (0.001 Pa s) lubricant, but increased with increasing viscosity value. The frictional torque of the 200 microm clearance joint was high at very low viscosity levels, however, it reduced with increasing viscosity. It is concluded that a smaller clearance level can enhance the formation of an elastohydrodynamic lubrication (EHL) film, but this is at the cost of preventing fluid recovery between the bearing surfaces during the unloaded phase of walking. Larger clearance bearings allow a better recovery of lubricant during the unloaded phase, which is necessary for higher viscosity lubricants. The selection of the clearance value should therefore consider both the formation of the EHL film and the fluid recovery as a function of the physiological viscosity in order to get an optimal tribological performance for MOM hip joints. The application of either 25 per cent bovine serum or water in existing in vitro tribological study should

  20. Proficiency testing criteria for clearance level in solid waste gamma measurement in Taiwan.

    Science.gov (United States)

    Chen, Chun-Liang; Wang, Jeng-Jong; Chiu, Huang-Sheng

    2013-11-01

    To guarantee the measurement quality for clearance level in solid waste material, the Institute of Nuclear Energy Research (INER) established the criteria for proficiency testing of clearance level measurement. INER and the Taiwan Accreditation Foundation (TAF) organized the Technique Committee Meeting twice to discuss these criteria in 2011. The participating laboratories must completely conform to the ISO/IEC 17025, and they also must meet the requirements of the criteria. According to the criteria, the participating laboratories analyzed the minimum detectable amount (MDA) and that should be less than 20% of the clearance level (AMDA) given in the Atomic Energy Council's (AEC) "Regulations on Clearance Level for Radioactive Waste Management". The testing results should conform to the deviation and traceability requirements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Not All Children with Cystic Fibrosis Have Abnormal Esophageal Neutralization during Chemical Clearance of Acid Reflux.

    Science.gov (United States)

    Woodley, Frederick W; Moore-Clingenpeel, Melissa; Machado, Rodrigo Strehl; Nemastil, Christopher J; Jadcherla, Sudarshan R; Hayes, Don; Kopp, Benjamin T; Kaul, Ajay; Di Lorenzo, Carlo; Mousa, Hayat

    2017-09-01

    Acid neutralization during chemical clearance is significantly prolonged in children with cystic fibrosis, compared to symptomatic children without cystic fibrosis. The absence of available reference values impeded identification of abnormal findings within individual patients with and without cystic fibrosis. The present study aimed to test the hypothesis that significantly more children with cystic fibrosis have acid neutralization durations during chemical clearance that fall outside the physiological range. Published reference value for acid neutralization duration during chemical clearance (determined using combined impedance/pH monitoring) was used to assess esophageal acid neutralization efficiency during chemical clearance in 16 children with cystic fibrosis (3 to chemical clearance exceeded the upper end of the physiological range in 9 of 16 (56.3%) children with and in 3 of 16 (18.8%) children without cystic fibrosis ( p =0.0412). The likelihood ratio for duration indicated that children with cystic fibrosis are 2.1-times more likely to have abnormal acid neutralization during chemical clearance, and children with abnormal acid neutralization during chemical clearance are 1.5-times more likely to have cystic fibrosis. Significantly more (but not all) children with cystic fibrosis have abnormally prolonged esophageal clearance of acid. Children with cystic fibrosis are more likely to have abnormal acid neutralization during chemical clearance. Additional studies involving larger sample sizes are needed to address the importance of genotype, esophageal motility, composition and volume of saliva, and gastric acidity on acid neutralization efficiency in cystic fibrosis children.

  2. Technetium-99m mercaptoacetyltriglycine clearance values in children with minimal renal disease: can a normal range be determined?

    International Nuclear Information System (INIS)

    Meyer, G.; Hahn, K.; Piepsz, A.; Kolinska, J.; Lepej, J.; Sixt, R.

    1998-01-01

    Use of technetium-99m labelled mercaptoacetyltriglycine ( 99m Tc-MAG3) simplifies and improves the quantification of renal clearance in children by virtue of its permanent availability, good imaging properties and low radiation exposure. Due to the lack of reference values for 99m Tc-MAG3 clearance in children, the Paediatric Task Group of the EANM initiated a multicentre study to evaluate 99m Tc-MAG3 clearance values in children with minimal renal disease. One hundred and twenty-five children aged between 12 months and 17 years, classified as renally healthy using defined diagnostic criteria, were included in the study. 99m Tc-MAG3 clearance was calculated using an algorithm on the basis of a single blood sample taken at any time between 30 and 40 min after tracer injection. In addition, the absolute 99m -Tc-MAG3 clearance values were normalized to body surface area. For further evaluation the children were classified into several groups according to age. There was a continuous increase in non-corrected 99m Tc-MAG3 clearance values from the age of 1 year up to the age of 17 years (mean value 8 years: 208±66 ml/min). Normal clearance values for adults were achieved by the age of 8 years. Analysis of the relationship between non-corrected clearance and age yielded a correlation coefficient of r=0.7. When these absolute clearance values were normalized to body surface area, we found nearly constant clearance values for all age groups, with a mean clearance value of 315±114 ml/min x 1.73 m 2 . The correlation coefficient for the relationship between normalized clearance and age was r=0.28. In conclusion, the clearance of 99m Tc-MAG3 increases continuously throughout childhood into adolescence due to the maturation and growth of the kidney. After normalization of the absolute clearance to body surface area, no correlation between clearance and age could be proven. (orig.)

  3. Dextran fractional clearance studies in acute dengue infection.

    Directory of Open Access Journals (Sweden)

    Julie Nguyen-Pouplin

    2011-08-01

    Full Text Available Although increased capillary permeability is the major clinical feature associated with severe dengue infections the mechanisms underlying this phenomenon remain unclear. Dextran clearance methodology has been used to investigate the molecular sieving properties of the microvasculature in clinical situations associated with altered permeability, including during pregnancy and in various renal disorders. In order to better understand the characteristics of the vascular leak associated with dengue we undertook formal dextran clearance studies in Vietnamese dengue patients and healthy volunteers.We carried out serial clearance studies in 15 young adult males with acute dengue and evidence of vascular leakage a during the phase of maximal leakage and b one and three months later, as well as in 16 healthy control subjects. Interestingly we found no difference in the clearance profiles of neutral dextran solutions among the dengue patients at any time-point or in comparison to the healthy volunteers.The surface glycocalyx layer, a fibre-matrix of proteoglycans, glycosaminoglycans, and plasma proteins, forms a complex with the underlying endothelial cells to regulate plasma volume within circumscribed limits. It is likely that during dengue infections loss of plasma proteins from this layer alters the permeability characteristics of the complex; physical and/or electrostatic interactions between the dextran molecules and the glycocalyx structure may temporarily restore normal function, rendering the technique unsuitable for assessing permeability in these patients. The implications for resuscitation of patients with dengue shock syndrome (DSS are potentially important. It is possible that continuous low-dose infusions of dextran may help to stabilize the permeability barrier in patients with profound or refractory shock, reducing the need for repeated boluses, limiting the total colloid volume required. Formal clinical studies should help to assess

  4. Surface code—biophysical signals for apoptotic cell clearance

    International Nuclear Information System (INIS)

    Biermann, Mona; Maueröder, Christian; Brauner, Jan M; Chaurio, Ricardo; Herrmann, Martin; Muñoz, Luis E; Janko, Christina

    2013-01-01

    Apoptotic cell death and the clearance of dying cells play an important and physiological role in embryonic development and normal tissue turnover. In contrast to necrosis, apoptosis proceeds in an anti-inflammatory manner. It is orchestrated by the timed release and/or exposure of so-called ‘find-me’, ‘eat me’ and ‘tolerate me’ signals. Mononuclear phagocytes are attracted by various ‘find-me’ signals, including proteins, nucleotides, and phospholipids released by the dying cell, whereas the involvement of granulocytes is prevented via ‘stay away’ signals. The exposure of anionic phospholipids like phosphatidylserine (PS) by apoptotic cells on the outer leaflet of the plasma membrane is one of the main ‘eat me’ signals. PS is recognized by a number of innate receptors as well as by soluble bridging molecules on the surface of phagocytes. Importantly, phagocytes are able to discriminate between viable and apoptotic cells both exposing PS. Due to cytoskeleton remodeling PS has a higher lateral mobility on the surfaces of apoptotic cells thereby promoting receptor clustering on the phagocyte. PS not only plays an important role in the engulfment process, but also acts as ‘tolerate me’ signal inducing the release of anti-inflammatory cytokines by phagocytes. An efficient and fast clearance of apoptotic cells is required to prevent secondary necrosis and leakage of intracellular danger signals into the surrounding tissue. Failure or prolongation of the clearance process leads to the release of intracellular antigens into the periphery provoking inflammation and development of systemic inflammatory autoimmune disease like systemic lupus erythematosus. Here we review the current findings concerning apoptosis-inducing pathways, important players of apoptotic cell recognition and clearance as well as the role of membrane remodeling in the engulfment of apoptotic cells by phagocytes. (paper)

  5. Trend of research and development on clearance system for CBRNE agents

    International Nuclear Information System (INIS)

    Ishihara, Masayuki; Fujita, Masanori; Ishida, Natsuko; Hattori, Hidemi; Tachibana, Shoich; Nakamura, Shingo; Kanatani, Yasuhiro

    2013-01-01

    In a field of disaster for a wide variety of Chemical, Biological, Radiological, Nuclear, Explosive (CBRNE) agents which are harmful and deadly poisonous, it is crucial to effectively clear those agents for prevention of expanded damages and retrieval from damage. The clearance technologies in the CBRNE disaster field require to be safe for human body and to be friendly for the environments. In addition, they need scientific data-based evidences for their effectiveness and safety. The aim of this article is to view the trend of research on clearances of N, B and c agents in terms of rapidity, simplicity and economic rationality, and to deliberate on effective clearance system using adequate equipments and materials for detoxification, decomposition and removal of each contamination. (author)

  6. Rate-Based Model Predictive Control of Turbofan Engine Clearance

    Science.gov (United States)

    DeCastro, Jonathan A.

    2006-01-01

    An innovative model predictive control strategy is developed for control of nonlinear aircraft propulsion systems and sub-systems. At the heart of the controller is a rate-based linear parameter-varying model that propagates the state derivatives across the prediction horizon, extending prediction fidelity to transient regimes where conventional models begin to lose validity. The new control law is applied to a demanding active clearance control application, where the objectives are to tightly regulate blade tip clearances and also anticipate and avoid detrimental blade-shroud rub occurrences by optimally maintaining a predefined minimum clearance. Simulation results verify that the rate-based controller is capable of satisfying the objectives during realistic flight scenarios where both a conventional Jacobian-based model predictive control law and an unconstrained linear-quadratic optimal controller are incapable of doing so. The controller is evaluated using a variety of different actuators, illustrating the efficacy and versatility of the control approach. It is concluded that the new strategy has promise for this and other nonlinear aerospace applications that place high importance on the attainment of control objectives during transient regimes.

  7. A parameters optimization method for planar joint clearance model and its application for dynamics simulation of reciprocating compressor

    Science.gov (United States)

    Hai-yang, Zhao; Min-qiang, Xu; Jin-dong, Wang; Yong-bo, Li

    2015-05-01

    In order to improve the accuracy of dynamics response simulation for mechanism with joint clearance, a parameter optimization method for planar joint clearance contact force model was presented in this paper, and the optimized parameters were applied to the dynamics response simulation for mechanism with oversized joint clearance fault. By studying the effect of increased clearance on the parameters of joint clearance contact force model, the relation of model parameters between different clearances was concluded. Then the dynamic equation of a two-stage reciprocating compressor with four joint clearances was developed using Lagrange method, and a multi-body dynamic model built in ADAMS software was used to solve this equation. To obtain a simulated dynamic response much closer to that of experimental tests, the parameters of joint clearance model, instead of using the designed values, were optimized by genetic algorithms approach. Finally, the optimized parameters were applied to simulate the dynamics response of model with oversized joint clearance fault according to the concluded parameter relation. The dynamics response of experimental test verified the effectiveness of this application.

  8. Cerebrospinal fluid clearance in Alzheimer disease measured with dynamic PET

    DEFF Research Database (Denmark)

    De Leon, Mony J.; Li, Yi; Okamura, Nobuyuki

    2017-01-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribrif......Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing...

  9. Selective targeted delivery of the TNF-alpha receptor p75 and uteroglobin to the vasculature of inflamed tissues: a preliminary report

    Directory of Open Access Journals (Sweden)

    Ventura Elisa

    2011-11-01

    Full Text Available Abstract Background Ligand-targeted approaches have proven successful in improving the therapeutic index of a number of drugs. We hypothesized that the specific targeting of TNF-alpha antagonists to inflamed tissues could increase drug efficacy and reduce side effects. Results Using uteroglobin (UG, a potent anti-inflammatory protein, as a scaffold, we prepared a bispecific tetravalent molecule consisting of the extracellular ligand-binding portion of the human TNF-alpha receptor P75 (TNFRII and the scFv L19. L19 binds to the ED-B containing fibronectin isoform (B-FN, which is expressed only during angiogenesis processes and during tissue remodeling. B-FN has also been demonstrated in the pannus in rheumatoid arthritis. L19-UG-TNFRII is a stable, soluble homodimeric protein that maintains the activities of both moieties: the immuno-reactivity of L19 and the capability of TNFRII to inhibit TNF-alpha. In vivo bio-distribution studies demonstrated that the molecule selectively accumulated on B-FN containing tissues, showing a very fast clearance from the blood but a very long residence time on B-FN containing tissues. Despite the very fast clearance from the blood, this fusion protein was able to significantly improve the severe symptomatology of arthritis in collagen antibody-induced arthritis (CAIA mouse model. Conclusions The recombinant protein described here, able to selectively deliver the TNF-alpha antagonist TNFRII to inflamed tissues, could yield important contributions for the therapy of degenerative inflammatory diseases.

  10. Influence of tip clearance on flow behavior and noise generation of centrifugal compressors in near-surge conditions

    International Nuclear Information System (INIS)

    Galindo, J.; Tiseira, A.; Navarro, R.; López, M.A.

    2015-01-01

    Highlights: • Centrifugal compressor aeroacoustics sensitivity to tip clearance is investigated. • 3 different clearance ratios are set in accordance to expected operating values. • Pressure spectra do not depend on tip clearance ratio in near-surge conditions. • DES performs better than URANS in predicting compressor acoustic signature. • Flow field observation reveals that tip clearance is immersed in rotating backflow. - Abstract: CFD has become an essential tool for researchers to analyze centrifugal compressors. Tip leakage flow is usually considered one of the main mechanisms that dictate compressor flow field and stability. However, it is a common practice to rely on CAD tip clearance, even though the gap between blades and shroud changes when compressor is running. In this paper, sensitivity of centrifugal compressor flow field and noise prediction to tip clearance ratio is investigated. 3D CFD simulations are performed with three different tip clearance ratios in accordance to expected operating values, extracted from shaft motion measurements and FEM predictions of temperature and rotational deformation. Near-surge operating conditions are simulated with URANS and DES. DES shows superior performance for acoustic predictions. Cases with reduced tip clearance present higher pressure ratio and isentropic efficiency, but no significant changes in compressor acoustic signature are found when varying clearance. In this working point, tip clearance is immersed in a region of strongly swirling backflow. Therefore, tip leakage cannot establish any coherent noise source mechanism

  11. Decreased insulin clearance in individuals with elevated 1-h post-load plasma glucose levels.

    Directory of Open Access Journals (Sweden)

    Maria Adelaide Marini

    Full Text Available Reduced insulin clearance has been shown to predict the development of type 2 diabetes. Recently, it has been suggested that plasma glucose concentrations ≥ 8.6 mmol/l (155 mg/dl at 1 h during an oral glucose tolerance test (OGTT can identify individuals at high risk for type 2 diabetes among those who have normal glucose tolerance (NGT 1 h-high. The aim of this study was to examine whether NGT 1 h-high have a decrease in insulin clearance, as compared with NGT individuals with 1-h post-load glucose <8.6 mmol/l (l (155 mg/dl, NGT 1 h-low. To this end, 438 non-diabetic White individuals were subjected to OGTT and euglycemic-hyperinsulinemic clamp to evaluate insulin clearance and insulin sensitivity. As compared with NGT 1 h-low individuals, NGT 1 h-high had significantly higher 1-h and 2-h post-load plasma glucose and 2-h insulin levels as well as higher fasting glucose and insulin levels. NGT 1 h-high exhibited also a significant decrease in both insulin sensitivity (P<0.0001 and insulin clearance (P = 0.006 after adjusting for age, gender, adiposity measures, and insulin sensitivity. The differences in insulin clearance remained significant after adjustment for fasting glucose (P = 0.02 in addition to gender, age, and BMI. In univariate analyses adjusted for gender and age, insulin clearance was inversely correlated with body weight, body mass index, waist, fat mass, 1-h and 2-h post-load glucose levels, fasting, 1-h and 2-h post-load insulin levels, and insulin-stimulated glucose disposal. In conclusion, our data show that NGT 1 h-high have a reduction in insulin clearance as compared with NGT 1 h-low individuals; this suggests that impaired insulin clearance may contribute to sustained fasting and post-meal hyperinsulinemia.

  12. Antibody or Antibody Fragments: Implications for Molecular Imaging and Targeted Therapy of Solid Tumors

    Directory of Open Access Journals (Sweden)

    Katerina T. Xenaki

    2017-10-01

    Full Text Available The use of antibody-based therapeutics has proven very promising for clinical applications in cancer patients, with multiple examples of antibodies and antibody–drug conjugates successfully applied for the treatment of solid tumors and lymphomas. Given reported recurrence rates, improvements are clearly still necessary. A major factor limiting the efficacy of antibody-targeted cancer therapies may be the incomplete penetration of the antibody or antibody–drug conjugate into the tumor. Incomplete tumor penetration also affects the outcome of molecular imaging, when using such targeting agents. From the injection site until they arrive inside the tumor, targeting molecules are faced with several barriers that impact intratumoral distribution. The primary means of antibody transport inside tumors is based on diffusion. The diffusive penetration inside the tumor is influenced by both antibody properties, such as size and binding affinity, as well as tumor properties, such as microenvironment, vascularization, and targeted antigen availability. Engineering smaller antibody fragments has shown to improve the rate of tumor uptake and intratumoral distribution. However, it is often accompanied by more rapid clearance from the body and in several cases also by inherent destabilization and reduction of the binding affinity of the antibody. In this perspective, we discuss different cancer targeting approaches based on antibodies or their fragments. We carefully consider how their size and binding properties influence their intratumoral uptake and distribution, and how this may affect cancer imaging and therapy of solid tumors.

  13. The Swedish nuclear industry way to approach higher demands on characterisation prior to clearance

    International Nuclear Information System (INIS)

    Larsson, Arne; Hellsten, Erik; Berglund, Malin; Larsson, Lars

    2012-01-01

    The Swedish Radiation Safety Authority (SSM) has introduced new regulations for clearance SSMFS 2011:2 'Regulations concerning clearance of material, rooms, buildings and soil from activities with ionizing radiation'. The new regulations came into force January 1, 2012. Compared to the previous regulations these new regulations have a broader scope and have introduced new conditions such as nuclide specific clearance levels. Clearance is practiced to reduce the amount of radioactive waste generated. Cleared material can be reused, recycled or if these two possibilities are not available, disposed of as conventional waste. To be able to meet the requirements for clearance the Swedish nuclear industry has jointly developed guidance for clearance in the form of a handbook and a training course covering the competence requirements in the new regulations. The handbook was developed by a team of representatives from the Swedish nuclear license holders managed by Studsvik on behalf of Swedish Nuclear Fuel and Waste Management Company (SKB). The training program was developed in co-operation between Nuclear Safety and training Company (KSU) and Studsvik on behalf of the Swedish nuclear license holders. A major challenge in the adoption to the new regulations is how to provide robust yet cost effective characterisation data. This is especially difficult for mobile materials and equipment which cannot be fully tracked but also for other materials and areas where the nuclide fingerprint has varied over the years. To be able to deal with these issues a lot of attention has to be paid to the historical inventory records and traceability in the clearance process. Materials, rooms and buildings have been divided in four categories with different requirements on frequency and requirements of measurements. The categories are named 'extremely small risk', 'small risk', 'risk' and 'known contamination above clearance levels'. The two day training course is dived into seven parts

  14. Nanomedicine targeting the tumor microenvironment: Therapeutic strategies to inhibit angiogenesis, remodel matrix, and modulate immune responses

    Directory of Open Access Journals (Sweden)

    Elizabeth L. Siegler

    2016-11-01

    Full Text Available Increasing attention has been given to the tumor microenvironment (TME, which includes cellular and structural components such as fibroblasts, immune cells, vasculature, and extracellular matrix (ECM that surround tumor sites. These components contribute to tumor growth and metastasis and are one reason why traditional chemotherapy often is insufficient to eradicate the tumor completely. Newer treatments that target aspects of the TME, such as antiangiogenic and immunostimulatory therapies, have seen limited clinical success despite promising preclinical results. This can be attributed to a number of reasons, including a lack of drug penetration deeper into the necrotic tumor core, nonspecific delivery, rapid clearance from serum, or toxic side effects at high doses. Nanoparticles offer a potential solution to all of these obstacles, and many recent studies have shown encouraging results using nanomedicine to target TME vasculature, ECM, and immune response. While few of these platforms have made it to clinical trials to date, these strategies are relatively new and may offer a way to improve the effects of anticancer therapies.

  15. Quantitative assessment of caffeine partial clearances in man.

    Science.gov (United States)

    Lelo, A; Miners, J O; Robson, R A; Birkett, D J

    1986-01-01

    Five subjects who participated in an earlier study (Lelo et al., 1986b) of the comparative pharmacokinetics of caffeine (CA) and its primary monodemethylated metabolites paraxanthine (PX), theobromine (TB) and theophylline (TP) were administered CA to steady-state. Using areas under the plasma concentration-time curves for each of the dimethylxanthines derived from CA in the steady-state study and individual plasma clearances of PX, TB and TP determined in the previous study, the fractional conversion of CA to PX, TB and TP and the individual partial clearances of CA have been defined. The mean (+/- s.d.) fractional conversion of CA to PX, TB and TP was 79.6 +/- 21.0%, 10.8 +/- 2.4% and 3.7 +/- 1.3%, respectively. When only demethylation pathways are considered PX, TB and TP accounted for 83.9 +/- 5.4%, 12.1 +/- 4.1% and 4.0 +/- 1.4%, respectively of the CA demethylations. The mean partial clearance of CA to PX was approximately 8-fold and 23-fold greater than those to TB and TP respectively. These data confirm earlier reports that PX is the major metabolite of CA in humans but suggest that PX formation is quantitatively more important than previously believed. PMID:3756066

  16. Decision Assessment of Clearance Level on Radioactive Waste Management

    International Nuclear Information System (INIS)

    Zainus Salimin; Gunandjar

    2007-01-01

    Radioactive waste on the safe level activity containing very small radioactive material gives small radiology influence to the human, it is not necessary to control by regulatory body. The radioactive waste on the safe level activity is safe to release as the common waste. For exemption of the control, it is required the safe activity level limits in which the value of clearance level is fulfilled by regulatory body, however until now it is not decided yet. The exemption decision is obtained if its activity is lower than or same with clearance level based on the annual effective dose receiving by public on the value is lower than or same with 0,01 mSv. The exposure pathways of radioactive waste to the human have important role for determination of clearance level. The decision assessment of clearance level on the radioactive waste management has been done by analysis of radioactive exposure pathways to the human for activities of the disposal and the recycle of solid wastes, also the release of liquid and gas effluent. For solid waste disposal, the exposure pathway was evaluated since the transportation of packed waste from the treatment facility to the disposal facility and during its operation. Exposure pathways for solid waste recycle consist of the pathways for handling and transportation of cleared material to the recycling facility, the fabrication and the utilization of its product. Exposure pathways for liquid and gas releases occur since its releases to the environment up to the human (public) by specific traffic lane. (author)

  17. Development of technique for quantifying gamma emitters in metal waste. New technique of precise and automatic measurements for confirmation of clearance level of metal waste

    International Nuclear Information System (INIS)

    Hattori, Takatoshi

    2002-01-01

    A New technique of precise and automatic measurements of gamma emitters in metal waste has been developed using 3D non-contact shape measurement and monte-carlo calculation techniques in order to confirm that specific radioactivity level of metal waste satisfies the clearance level and furthermore the surface contamination level of the metal waste is below the legal standard level. The technique can give a calibration factor every measurement target automatically and realize an automatic correction for reduction of background count rate in gamma measurements due to self-shield effect of the measurement target. The accuracy of the present method has been made clear using mock-metal wastes with various types of shape, number and size. Assuming the goal of the detection limit for practical use is 25OBq in radioactivity, a concept of the practical gamma monitor has been designed so as to be able to confirm both the clearance level and surface contamination level simultaneously and to cope with the metal waste at a speed of 2-10 ton a day. (author)

  18. Bromsulphalein (BSP) clearance in ageing rats

    NARCIS (Netherlands)

    Hollander, C.F.; Leeuw-Israel, F.R. de; Arp-Neefjes, J.M.

    1968-01-01

    Liver function in ageing rats was studied, using the bromsulphalein (BSP) clearance test. The test was done on ultramicro scale. This made it possible to repeat the test several times in the same animal and to start a longitudinal study. In 3-month-old rats the BSP retentions, measured 15, 30 and 45

  19. Non-destructive clearance measuring in closed joints

    International Nuclear Information System (INIS)

    Doucelance, C.; Manaranche, J.C.

    1976-01-01

    Two methods for clearance measuring in closed joints are described. The first one is based on the mechanical impedance concept, while the other one requires a shock test on shaker. Both are illustrated with an example of application [fr

  20. β-Amyloid promotes accumulation of lipid peroxides by inhibiting CD36-mediated clearance of oxidized lipoproteins

    Directory of Open Access Journals (Sweden)

    Khan Tayeba

    2004-11-01

    Full Text Available Abstract Background Recent studies suggest that hypercholesterolemia, an established risk factor for atherosclerosis, is also a risk factor for Alzheimer's disease. The myeloid scavenger receptor CD36 binds oxidized lipoproteins that accumulate with hypercholesterolemia and mediates their clearance from the circulation and peripheral tissues. Recently, we demonstrated that CD36 also binds fibrillar β-amyloid and initiates a signaling cascade that regulates microglial recruitment and activation. As increased lipoprotein oxidation and accumulation of lipid peroxidation products have been reported in Alzheimer's disease, we investigated whether β-amyloid altered oxidized lipoprotein clearance via CD36. Methods The availability of mice genetically deficient in class A (SRAI & II and class B (CD36 scavenger receptors has facilitated studies to discriminate their individual actions. Using primary microglia and macrophages, we assessed the impact of Aβ on: (a cholesterol ester accumulation by GC-MS and neutral lipid staining, (b binding, uptake and degradation of 125I-labeled oxidized lipoproteins via CD36, SR-A and CD36/SR-A-independent pathways, (c expression of SR-A and CD36. In addition, using mice with targeted deletions in essential kinases in the CD36-signaling cascade, we investigated whether Aβ-CD36 signaling altered metabolism of oxidized lipoproteins. Results In primary microglia and macrophages, Aβ inhibited binding, uptake and degradation of oxidized low density lipoprotein (oxLDL in a dose-dependent manner. While untreated cells accumulated abundant cholesterol ester in the presence of oxLDL, cells treated with Aβ were devoid of cholesterol ester. Pretreatment of cells with Aβ did not affect subsequent degradation of oxidized lipoproteins, indicating that lysosomal accumulation of Aβ did not disrupt this degradation pathway. Using mice with targeted deletions of the scavenger receptors, we demonstrated that Aβ inhibited oxidized

  1. Hyperinsulinism and polycystic ovary syndrome (PCOS): role of insulin clearance.

    Science.gov (United States)

    Amato, M C; Vesco, R; Vigneri, E; Ciresi, A; Giordano, C

    2015-12-01

    Insulin resistance and compensatory hyperinsulinism are the predominant metabolic defects in polycystic ovary syndrome (PCOS). However, hyperinsulinism, as well as being compensatory, can also express a condition of reduced insulin clearance. Our aim was to evaluate the differences in insulin action and metabolism between women with PCOS (with normal glucose tolerance) and age- and BMI-matched women with prediabetes (without hyperandrogenism and ovulatory disorders). 22 women with PCOS and 21 age/BMI-matched women with prediabetes were subjected to a Hyperinsulinemic-euglycemic clamp and an Oral Glucose tolerance Test (OGTT). Insulin sensitivity was assessed by the glucose infusion rate during clamp (M value); insulin secretion by Insulinogenic index, Oral Disposition Index (DIo) and AUC(2h-insulin) during OGTT; and insulin clearance by the metabolic clearance rate of insulin (MCRI) during clamp. Women with PCOS showed significantly higher levels of AUC(2h-insulin) (p PCOS [420 (IQR 227-588) vs. 743 (IQR 597-888) ml m(-2) min(-1): p PCOS group, a strong independent inverse correlation was only observed between MCRI and AUC(2h-insulin) (PCOS: β:-0.878; p PCOS there is peripheral insulin sensitivity similar to that of women with prediabetes. What sets PCOS apart is the hyperinsulinism, today still simplistically defined "compensatory"; actually this is mainly related to decreased insulin clearance whose specific causes and dynamics have yet to be clarified.

  2. 133 xenon muscle clearance as a test parameter in the diagnosis of peripheral diabetic angiopathies

    International Nuclear Information System (INIS)

    Kuhlmann, J.E.

    1980-01-01

    In 100 patients with manifest diabetes mellitus the irrigation in both legs at rest and in radioactive hyperemia after ischemic muscle work was measured by means of the 133-xenon muscle clearance. The clearance values measured ranged between 0.8 and 3.5 ml/100 g/60 s at rest and between 3.3 and 40.0 ml/100 gl/60 s during radioactive hyperemia. In 96 pc of the probands the irrigation of the legs was impaired. For the relation between glucose level and irrigation at rest a significant negative correlation was found. The difference between the clearance values for the right and left lower extremity was significant. For the relation between glucose level and reactive hyperemia, too, a significant negative correlation was found. The difference between the clearance values for the right and left lower extremities was significant. The measurement of the irrigation at rest showed no significant correlation between the period of manifestation of the diabetes and the clearance values. By contrast, the irrigation values during reactive hyperemia were shown to be in significantly negative correlation to the duration of the diabetes. No connection was found between the frequency of diabetic gangrene and impaired irrigation at rest. By contrast, there was a relation between decreasing hyperemia values and increased frequency of gangrene. A collection of case histories shows how the measuring results of the xenon clearance fit into the overall clinical picture. A comparison of xenon clearance with other methods of irrigation measurement confirmed obvious advantages of xenon clearance for the detection of diabetic microangiopathies. (orig./MG) [de

  3. Serial thallium-201 imaging after dipyridamole for coronary disease detection: quantitative analysis using myocardial clearance

    International Nuclear Information System (INIS)

    Okada, R.D.; Dai, Y.H.; Boucher, C.A.; Pohost, G.M.

    1984-01-01

    After dipyridamole, canine studies have demonstrated a slower rate of myocardial thallium-201 clearance from zones distal to a coronary artery stenosis compared to normal zones. To determine if criteria based on canine myocardial thallium-201 clearance rates could be applied clinically, 40 patients with and 26 patients without coronary artery disease (CAD) had serial thallium-201 images obtained for 2 to 5 hours after dipyridamole. Regions of interest were manually placed over six left ventricular segments in two projections for each of three imaging times. The myocardial thallium-201 clearance rate was calculated for each of the six segments and, using the clearance rate criterion found in canine studies, was considered abnormal if less than 6.5%/hr. Using this criterion alone, 22 of 26 patients (85%) without CAD had normal and 30 of 40 patients (75%) with CAD had abnormal myocardial thallium-201 clearance rates. A quantitative analysis of regional inhomogeneity in tracer distribution (normal was greater than or equal to 25% difference between segments) was negative in 24 of 26 patients (92%) without CAD and positive in 20 of 40 patients (50%) with CAD. When both clearance rate and regional inhomogeneity were considered, 21 of 26 patients (81%) without CAD had negative and 36 of 40 patients (90%) with CAD had positive results. Thus, post-dipyridamole myocardial clearance rate criteria derived from canine studies can be applied to clinical thallium imaging. Quantitative analysis of serial thallium-201 images after dipyridamole is optimized by using myocardial thallium-201 clearance rates. Such an approach is independent of regional inhomogeneities in tracer distribution

  4. Clearance of buildings for demolition: ways to clearance on the standing structure for covered surfaces and inaccessible areas

    International Nuclear Information System (INIS)

    Thraenert, S.; Riemann, T.

    2014-01-01

    In general terms, the TUV NORD Nuclear services encompass safety assessments, design reviews, documentation re-views and inspections. They reflect the full scope of a technical service provider in the nuclear field. In the domestic market, these services are provided for the regulator, whereas in the international market any party involved in a nuclear project is a potential customer of TUV NORD Nuclear. This implies that TUV NORD Nuclear is offering consultancy, engineering and inspection services. Regarding the clearance of buildings for demolition, there are two different possible ways for the radiological characterization. The first option is a characterization on the standing structure before demolition and the second option is the characterization of the building rubble after demolition. According to the German Radiation Protection Ordinance, buildings of decommissioned nuclear sites have to be preferentially cleared on the standing structure. If compliance with the surface specific clearance levels is achieved on the standing structure, usually the cleared buildings can be demolished and the resulting rubble may be used without any further radiological considerations. In the case of the former nuclear power plant Wuergassen the majority of the building rubble is scheduled to stay on site to serve as backfill for the building pit. As such a scenario was not considered in the radiological considerations of, e.g., the German Radiation Protection Ordinance, an additional dose calculation was carried out for Wuergassen NPP basing on its radiological characteristics to directly prove compliance with the de-minimis-concept. The radiation controlled area (RCA) of Wuergassen NPP comprises an area of about 140.000 m 2 . This area is more or less easily accessible to characterization and decontamination using, if necessary, scaffoldings or lifting platforms. Up to the beginning of 2013, compliance with the surface specific clearance levels was verified on the standing

  5. Lithium clearance and renal tubular sodium handling during acute and long-term nifedipine treatment in essential hypertension

    DEFF Research Database (Denmark)

    Bruun, N E; Ibsen, H; Skøtt, P

    1988-01-01

    1. In two separate studies the lithium clearance method was used to evaluate the influence of acute and long-term nifedipine treatment on renal tubular sodium reabsorption. 2. In the acute study, after a 4 week placebo period two doses of 20 mg of nifedipine decreased supine blood pressure from 155...... were also unchanged, as were potassium clearance, urine flow and body weight. 3. In the long-term study, lithium clearance, glomerular filtration rate, sodium clearance, potassium clearance, urine flow and body fluid volumes were measured after a 4 weeks placebo period and after 6 and 12 weeks....../101 (20.6/13.5) +/- 11/4 (1.5/0.5) to 139/88 (18.5/11.7) +/- 16/9 (2.1/1.2) mmHg (kPa) (means +/- SD; P less than 0.01). Lithium clearance, glomerular filtration rate and sodium clearance did not change. Therefore the calculated values of absolute proximal and absolute distal sodium reabsorption rates...

  6. Effect of tip clearance on performance of small axial hydraulic turbine

    Science.gov (United States)

    Boynton, J. L.; Rohlik, H. E.

    1976-01-01

    The first two stages of a six stage liquid oxygen turbine were tested in water. One and two stage performance was determined for one shrouded and two unshrouded blade end configurations over ranges of clearance and blade-jet speed ratio. First stage, two stage, and second stage efficiencies are included as well as the effect of clearance on mass flow for two stage operation.

  7. Measurement of apolipoprotein E and amyloid β clearance rates in the mouse brain using bolus stable isotope labeling

    Science.gov (United States)

    2012-01-01

    Background Abnormal proteostasis due to alterations in protein turnover has been postulated to play a central role in several neurodegenerative diseases. Therefore, the development of techniques to quantify protein turnover in the brain is critical for understanding the pathogenic mechanisms of these diseases. We have developed a bolus stable isotope-labeling kinetics (SILK) technique coupled with multiple reaction monitoring mass spectrometry to measure the clearance of proteins in the mouse brain. Results Cohorts of mice were pulse labeled with 13 C6-leucine and the brains were isolated after pre-determined time points. The extent of label incorporation was measured over time using mass spectrometry to measure the ratio of labeled to unlabeled apolipoprotein E (apoE) and amyloid β (Aβ). The fractional clearance rate (FCR) was then calculated by analyzing the time course of disappearance for the labeled protein species. To validate the technique, apoE clearance was measured in mice that overexpress the low-density lipoprotein receptor (LDLR). The FCR in these mice was 2.7-fold faster than wild-type mice. To demonstrate the potential of this technique for understanding the pathogenesis of neurodegenerative disease, we applied our SILK technique to determine the effect of ATP binding cassette A1 (ABCA1) on both apoE and Aβ clearance. ABCA1 had previously been shown to regulate both the amount of apoE in the brain, along with the extent of Aβ deposition, and represents a potential molecular target for lowering brain amyloid levels in Alzheimer's disease patients. The FCR of apoE was increased by 1.9- and 1.5-fold in mice that either lacked or overexpressed ABCA1, respectively. However, ABCA1 had no effect on the FCR of Aβ, suggesting that ABCA1 does not regulate Aβ metabolism in the brain. Conclusions Our SILK strategy represents a straightforward, cost-effective, and efficient method to measure the clearance of proteins in the mouse brain. We expect that

  8. Thickness and clearance visualization based on distance field of 3D objects

    Directory of Open Access Journals (Sweden)

    Masatomo Inui

    2015-07-01

    Full Text Available This paper proposes a novel method for visualizing the thickness and clearance of 3D objects in a polyhedral representation. The proposed method uses the distance field of the objects in the visualization. A parallel algorithm is developed for constructing the distance field of polyhedral objects using the GPU. The distance between a voxel and the surface polygons of the model is computed many times in the distance field construction. Similar sets of polygons are usually selected as close polygons for close voxels. By using this spatial coherence, a parallel algorithm is designed to compute the distances between a cluster of close voxels and the polygons selected by the culling operation so that the fast shared memory mechanism of the GPU can be fully utilized. The thickness/clearance of the objects is visualized by distributing points on the visible surfaces of the objects and painting them with a unique color corresponding to the thickness/clearance values at those points. A modified ray casting method is developed for computing the thickness/clearance using the distance field of the objects. A system based on these algorithms can compute the distance field of complex objects within a few minutes for most cases. After the distance field construction, thickness/clearance visualization at a near interactive rate is achieved.

  9. Energy Performance and Radial Force of a Mixed-Flow Pump with Symmetrical and Unsymmetrical Tip Clearances

    Directory of Open Access Journals (Sweden)

    Yue Hao

    2017-01-01

    Full Text Available The energy performance and radial force of a mixed flow pump with symmetrical and unsymmetrical tip clearance are investigated in this paper. As the tip clearance increases, the pump head and efficiency both decrease. The center of the radial force on the principal axis is located at the coordinate origin when the tip clearance is symmetrical, and moves to the third quadrant when the tip clearance is unsymmetrical. Analysis results show that the total radial force on the principal axis is closely related to the fluctuation of mass flow rate in each single flow channel. Unsteady simulations show that the dominant frequencies of radial force on the hub and blade correspond to the blade number, vane number, or double blade number because of the rotor stator interaction. The radial force on the blade pressure side decreases with the tip clearance increase because of leakage flow. The unsymmetrical tip clearances in an impeller induce uneven leakage flow rate and then result in unsymmetrical work ability of each blade and flow pattern in each channel. Thus, the energy performance decreases and the total radial force increases for a mixed flow pump with unsymmetrical tip clearance.

  10. 76 FR 24920 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-05-03

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  11. 76 FR 35069 - Agency Information Collection Activities; Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-06-15

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...; Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  12. 78 FR 74175 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2013-12-10

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  13. 77 FR 52708 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2012-08-30

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  14. 76 FR 9819 - Agency Information Collection Activities: Proposed Collection; Generic Clearance for the...

    Science.gov (United States)

    2011-02-22

    ...; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery; Correction AGENCY...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Regulatory Commission, Office of Personnel Management, Small Business Administration, and U.S. Agency for...

  15. Turbine Engine Clearance Control Systems: Current Practices and Future Directions

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.

    2002-01-01

    Improved blade tip sealing in the high pressure compressor (HPC) and high pressure turbine (HPT) can provide dramatic reductions in specific fuel consumption (SFC), time-on-wing, compressor stall margin, and engine efficiency as well as increased payload and mission range capabilities. Maintenance costs to overhaul large commercial gas turbine engines can easily exceed $1M. Engine removal from service is primarily due to spent exhaust gas temperature (EGT) margin caused mainly by the deterioration of HPT components. Increased blade tip clearance is a major factor in hot section component degradation. As engine designs continue to push the performance envelope with fewer parts and the market drives manufacturers to increase service life, the need for advanced sealing continues to grow. A review of aero gas turbine engine HPT performance degradation and the mechanisms that promote these losses are discussed. Benefits to the HPT due to improved clearance management are identified. Past and present sealing technologies are presented along with specifications for next generation engine clearance control systems.

  16. Regulation Concepts for Clearance Level of Radionuclide in Solid Materials

    International Nuclear Information System (INIS)

    Nanang Triagung Edi Hermawan

    2008-01-01

    Practices of nuclear energy have expanded in some fields such as researches and development, educations, agricultures, medicines and industries. Every practice beside give much benefit, could generate residue or waste. Radioactive waste needs management to ensure the safety of workers, member of the public, and for the eternal of environment. The product of radioactive waste management, in generally, is some containment of radionuclide concentration in solid matrix material after immobilization or conditioning process. Some kind of processed radioactive wastes with short half live then decay faster to stabile condition. The decay will reach clearance level in sometimes, so from the radiation protection views is harmless. This materials above didn’t need control and must be cleared from all determinate and regulation aspects of radioactive material practices. There is clearance for harmless material off course will be simplify management task and efficiency of money. So the regulation about clearance levels will be important as law basic for technical practices in field. (author)

  17. Dynamic Studies of Lung Fluid Clearance with Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Kitchen, Marcus J.; Williams, Ivan; Irvine, Sarah C.; Morgan, Michael J.; Paganin, David M.; Lewis, Rob A.; Pavlov, Konstantin; Hooper, Stuart B.; Wallace, Megan J.; Siu, Karen K. W.; Yagi, Naoto; Uesugi, Kentaro

    2007-01-01

    Clearance of liquid from the airways at birth is a poorly understood process, partly due to the difficulties of observing and measuring the distribution of air within the lung. Imaging dynamic processes within the lung in vivo with high contrast and spatial resolution is therefore a major challenge. However, phase contrast X-ray imaging is able to exploit inhaled air as a contrast agent, rendering the lungs of small animals visible due to the large changes in the refractive index at air/tissue interfaces. In concert with the high spatial resolution afforded by X-ray imaging systems (<100 μm), propagation-based phase contrast imaging is ideal for studying lung development. To this end we have utilized intense, monochromatic synchrotron radiation, together with a fast readout CCD camera, to study fluid clearance from the lungs of rabbit pups at birth. Local rates of fluid clearance have been measured from the dynamic sequences using a single image phase retrieval algorithm

  18. Understanding of the Interaction between Clearance Leakage Flow and Main Passage Flow in a VGT Turbine

    Directory of Open Access Journals (Sweden)

    Ben Zhao

    2015-02-01

    Full Text Available The clearance flow between the nozzle and endwall in a variable geometry turbine (VGT has been numerically investigated to understand the clearance effect on the VGT performance and internal flow. It was found that the flow rate through turbine increases but the turbine efficiency decreases with height of clearance. Detailed flow field analyses indicated that most of the efficiency loss resulting from the leakage flow occurs at the upstream of the rotor area, that is, in the nozzle endwall clearance and between the nozzle vanes. There are two main mechanisms associated with this efficiency loss. One is due to the formation of the local vortex flow structure between the clearance flow and the main flow. The other is due to the impact of the clearance flow on the main flow after the nozzle throat. This impact reduces the span of shockwave with increased shockwave magnitude by changing the trajectory of the main flow.

  19. The effects of selected air pollutants on clearance of titanic oxide particles from the lungs of rats.

    Science.gov (United States)

    Ferin, J; Leach, L J

    1975-09-01

    A procedure utilizing the lung clearance kinetics of titanic oxide (TiO2) particles was used to determine the effects of inhaled sulphur dioxide (SO2) and nitrogen oxides (NO x) on particle clearance. The procedure is reproducible and mainly tests clearance mechanisms involving alveolar macrophages and the mucociliary transport system at the alveolobronchial clearance pathway. At low SO2 or NOx exposures enhanced particle clearance was observed. Lung clearance was depressed at 15 and 24 ppm of NO2 after 22 exposures as well as at 20 ppm of SO2 after 11 exposures, and also at 1 ppm of SO2 after 25 exposures. Dose-response curves for the SO2 and NOx exposures showed differences explainable by the routes by which these gases reach the alveolar macrophages.

  20. Automated Real-Time Clearance Analyzer (ARCA), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Automated Real-Time Clearance Analyzer (ARCA) addresses the future safety need for Real-Time System-Wide Safety Assurance (RSSA) in aviation and progressively...

  1. Mergers: Success versus failure

    International Nuclear Information System (INIS)

    Carley, G. R.

    1997-01-01

    Successful mergers in the context of long-term value creation, as measured by return realized on investor-provided capital, were discussed. In essence, a successful merger is characterized by being motivated by a sound business reason and strategy for the merger, a reasonable price and sound execution. The acquiror's pre-merger success in managing a company is a good indicator of future success. Poorly managed companies that acquire other companies generally continue to be poorly managed with no significant increase in shareholder value. Prior to the acquisition, identification of the potential target, assessment of the people involved on both sides of the transaction, thorough knowledge of the target's potential for value creation, financial implications (debt, equity, terms and demand, tax implications, the potential effect of the proposed acquisition on the acquiror's business plan) and finally the execution of the process itself, are the important determinants of successful mergers

  2. 75 FR 38775 - Proposed Information Collection; Comment Request; Generic Clearance for Customer Satisfaction...

    Science.gov (United States)

    2010-07-06

    ...; Generic Clearance for Customer Satisfaction Research AGENCY: U.S. Census Bureau. ACTION: Notice. SUMMARY... Bureau is requesting an extension of the generic clearance to conduct customer satisfaction research... on feedback from its various customer satisfaction research efforts. Each research design is reviewed...

  3. 75 FR 80542 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2010-12-22

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  4. 76 FR 12140 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-04

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  5. 76 FR 19826 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-04-08

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  6. 76 FR 17861 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-31

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  7. 76 FR 41280 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-07-13

    ... proposed sample size, the expected response rate, methods for assessing potential non-response bias, the... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  8. 76 FR 25693 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-05-05

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  9. [Medical clearance for missions abroad (EEU): definitions, recommendations for use and performance].

    Science.gov (United States)

    Kollaritsch, Herwig; Wenisch, Christoph; Hatz, Christoph; von Laer, Gunther; Bauer, Bernd; Hollenstein, Ursula; Haditsch, Martin; Diridl, Gerhard; Malinowski, Waldemar; Jeschko, Eva; Payer-Neundlinger, Gabriela; Speiser-Remp, Nicole; Pichler, Hannes E T; Rumpold, Helmut; Stemberger, Heinrich; Eder, Gerald; Wiedermann, Gerhard; Wiedermann, Ursula

    2007-01-01

    Standards for medical clearance for private or business missions abroad are--at least in the German speaking countries--not clearly defined and mostly derived from the old terminus "Tropentauglichkeit" which means fit for mission in the tropics. The authors now define a new standard, called "Entsendungstauglichkeitsuntersuchung" which means clearance of fitness for all types of missions abroad, independent of distinct climatic zones. To meet the inhomogenous requirements of different institutions and different types of missions the medical examination proposed follows a modular structure to optimize economic and medical use of resources. Moreover, as Austria, Germany and Switzerland have different legal and economic postulates, the medical examination has to be adapted to the different premises. The definition and description of this special type of "medical clearance for missions abroad" is supplemented by recommendations for definitions of clients who should undergo such an investigation and the professionals who should perform this type of investigation. Additionally, results of this type of medical clearance are defined and prophylactic aspects in terms of pre-travel advice are mentioned.

  10. Lithium clearance method and the renal response to low-dose dopamine in man

    DEFF Research Database (Denmark)

    Olsen, N V; Olsen, M H; Fogh-Andersen, N

    1993-01-01

    .00 hours on three different occasions. After an overnight fast, the subjects were water-loaded and clearance studies were started at 09.00 hours with a 1h baseline period and three 1h periods during dopamine infusion. 2. Baseline sodium clearance with placebo was 0.65 +/- 0.35 ml/min, but with lithium......-induced changes in effective renal plasma flow, glomerular filtration rate or osmolal clearance. Neither lithium nor dopamine influenced plasma concentrations of renin, aldosterone or atrial natriuretic peptide. 4. In conclusion, single test doses of lithium, as normally used in lithium clearance studies......1. The effect of a single dose of lithium on renal function before and during intravenous infusion of dopamine (3 micrograms min-1 kg-1) was investigated in 12 healthy males. In a double-blind and randomized design, 450mg or 600mg of lithium carbonate or placebo was administered orally at 22...

  11. Lithium clearance method and the renal response to low-dose dopamine in man

    DEFF Research Database (Denmark)

    Olsen, Niels Vidiendal; Olsen, M H; Fogh-Andersen, N

    1993-01-01

    .00 hours on three different occasions. After an overnight fast, the subjects were water-loaded and clearance studies were started at 09.00 hours with a 1h baseline period and three 1h periods during dopamine infusion. 2. Baseline sodium clearance with placebo was 0.65 +/- 0.35 ml/min, but with lithium...... in effective renal plasma flow, glomerular filtration rate or osmolal clearance. Neither lithium nor dopamine influenced plasma concentrations of renin, aldosterone or atrial natriuretic peptide. 4. In conclusion, single test doses of lithium, as normally used in lithium clearance studies, increase baseline......1. The effect of a single dose of lithium on renal function before and during intravenous infusion of dopamine (3 micrograms min-1 kg-1) was investigated in 12 healthy males. In a double-blind and randomized design, 450mg or 600mg of lithium carbonate or placebo was administered orally at 22...

  12. Turbine blade tip clearance measurement using a skewed dual-beam fiber optic sensor

    Science.gov (United States)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2012-08-01

    Optimization and active control of the tip clearance of turbine blades has been identified as a key to improve fuel efficiency, reduce emission, and increase service life of the engine. However, reliable and real-time tip clearance measurement is difficult due to the adverse environmental conditions that are typically found in a turbine. We describe a dual-beam fiber optic measurement system that can measure the tip timing and tip clearance simultaneously. Because the tip timing information is used to calculate the tip clearance, the method is insensitive to the signal intensity variation caused by fluctuations in environmental conditions such as light source instability, contamination, and blade tip imperfection. The system was calibrated and tested using experimental rotors. The test results indicated a high resolution of 4.5 μm and measurement accuracy of ±20 μm over the rotation speed range of 2000 to 10,000 rpm.

  13. Radioactive clearance discharge of effluent from nuclear and radiation facilities

    International Nuclear Information System (INIS)

    Liu Xinhua; Xu Chunyan

    2013-01-01

    On the basis of the basic concepts of radiation safety management system exemption, exclusion and clearance, we expound that the general industrial gaseous and liquid effluent discharges are exempted or excluded, gaseous and liquid effluent discharged from nuclear and radiation facilities are clearance, and non-radioactive. The main purpose of this paper is to clarify the concepts, reach a consensus that the gaseous and liquid effluent discharged from nuclear and radiation facilities are non-radioactive and have no hazard to human health and natural environment. (authors)

  14. Effects and outcome of Tamsulosin more than just stone clearance after extracorporeal shock wave lithotripsy for renal calculi

    International Nuclear Information System (INIS)

    Qadri, S. S. U.; Khalid, S. E.; Mahmud, S. M.

    2014-01-01

    Objective: To determine the effect of Tamsulosin, as adjunctive medical therapy after Extracorporeal Shock Wave Lithotripsy for renal stones on rate of stone clearance, clearance time, pain intensity during stone clearance, steinstrasse formation and auxiliary surgical intervention required. Method: A prospective randomized controlled study was carried out in 120 patients who underwent ESWL for renal stones of 0.5-2.0 cm. They were randomized into study and control group in which Tamsulosin 0.4mg/day was given in former as an adjunctive medical therapy. All patients underwent ESWL every 2 weeks until complete stone clearance for 8 weeks. The parameters assessed were stone clearance, clearance time, pain intensity and effect on steinstrasse. Results: Of the 120 patients 60 were in each group. The stone clearance rate was greater in study than in control group, 58(96.7%) vs. 48(80%) respectively, (p<0.004). The mean stone clearance time was observed earlier in study group as compared to control group with significant statistical difference in stone size between 0.6-1.5 cm. The mean intensity of pain patients experienced according to Visual analogue scale (VAS) was significantly less in study group (p<0.002). The rate of steinstrasse formation was observed to be higher in control than in study group 15(25%) vs 6(10%) respectively(p<0.003), while its spontaneous clearance was higher in study group than in control group 83.3% vs 33.3% (p<0.03). Conclusion: Tamsulosin significantly increases stone clearance after shock wave lithotripsy for renal stones. It also appeared to facilitate earlier stone clearance, reduces severity of pain, reduces the incidence of steinstrasse formation and tends to facilitate its spontaneous clearance. (author)

  15. Viral Response to Specifically Targeted Antiviral Therapy for Hepatitis C and the Implications for Treatment Success

    Directory of Open Access Journals (Sweden)

    Curtis L Cooper

    2010-01-01

    Full Text Available Currently, hepatitis C virus (HCV antiviral therapy is characterized by long duration, a multitude of side effects, difficult administration and suboptimal success; clearly, alternatives are needed. Collectively, specifically targeted antiviral therapy for HCV (STAT-C molecules achieve rapid viral suppression and very high rapid virological response rates, and improve sustained virological response rates. The attrition rate of agents within this class has been high due to various toxicities. Regardless, several STAT-C molecules are poised to become the standard of care for HCV treatment in the foreseeable future. Optimism must be tempered with concerns related to the rapid development of drug resistance with resulting HCV rebound. Strategies including induction dosing with interferon and ribavirin, use of combination high-potency STAT-C molecules and an intensive emphasis on adherence to HCV antiviral therapy will be critical to the success of this promising advance in HCV therapy.

  16. Development of a Novel System to Measure a Clearance of a Passenger Platform

    Science.gov (United States)

    Shimizu, M.; Oizumi, J.; Matsuoka, R.; Takeda, H.; Okukura, H.; Ooya, A.; Koike, A.

    2016-06-01

    Clearances of a passenger platform at a railway station should be appropriately maintained for safety of both trains and passengers. In most Japanese railways clearances between a platform and a train car is measured precisely once or twice a year. Because current measurement systems operate on a track, the closure of the track is unavoidable. Since the procedure of the closure of a track is time-consuming and bothersome, we decided to develop a new system to measure clearances without the closure of a track. A new system is required to work on a platform and the required measurement accuracy is less than several millimetres. We have adopted a 3D laser scanner and stop-and-go operation for a new system. The current systems on a track measure clearances continuously at walking speed, while our system on a platform measures clearances at approximately ten metres intervals. The scanner controlled by a PC acquires a set of point data at each measuring station. Edge points of the platform, top and side points of two rails are detected from the acquired point data. Finally clearances of the platform are calculated by using the detected feature points of the platform and the rails. The results of an experiment using a prototype of our system show that the measurement accuracy by our system would be satisfactory, but our system would take more time than the current systems. Since our system requires no closure of a track, we conclude that our system would be convenient and effective.

  17. Effects of a Nonuniform Tip Clearance Profile on the Performance and Flow Field in a Centrifugal Compressor

    Directory of Open Access Journals (Sweden)

    Yohan Jung

    2012-01-01

    Full Text Available This paper presents a numerical investigation of the effects of a nonuniform tip clearance profile on the performance and flow field in a centrifugal compressor with a vaneless diffuser. This study focuses in particular on the magnitude and location of the wake. Six impellers with different tip clearance profiles were tested in the flow simulations. The accuracy of the numerical simulations was assessed by comparing the experimental data with the computational results for a system characterized by the original tip clearance. Although the performance improved for low tip clearances, a low tip clearance at the trailing edge improved the compressor performance more significantly than a low tip clearance at the leading edge. The flow field calculated for a system characterized by a low tip clearance at the trailing edge produced a more uniform velocity distribution both in the circumferential and in the axial directions at the impeller exit because the wake magnitude was reduced. As a consequence, this impeller provided a better potential for diffusion processes inside a vaneless diffuser.

  18. 78 FR 69643 - Proposed Information Collection; Comment Request; Generic Clearance for Customer Satisfaction...

    Science.gov (United States)

    2013-11-20

    ... Clearance for Customer Satisfaction Research AGENCY: U.S. Census Bureau, Commerce. ACTION: Notice. SUMMARY... requesting an extension of the generic clearance to conduct customer satisfaction research which may be in... feedback from its various customer satisfaction research efforts. Each research design is reviewed for...

  19. 76 FR 63301 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-10-12

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  20. 76 FR 15027 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-18

    ... clustering), the precision requirements or power calculations that justify the proposed sample size, the...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  1. Railway clearance intrusion detection method with binocular stereo vision

    Science.gov (United States)

    Zhou, Xingfang; Guo, Baoqing; Wei, Wei

    2018-03-01

    In the stage of railway construction and operation, objects intruding railway clearance greatly threaten the safety of railway operation. Real-time intrusion detection is of great importance. For the shortcomings of depth insensitive and shadow interference of single image method, an intrusion detection method with binocular stereo vision is proposed to reconstruct the 3D scene for locating the objects and judging clearance intrusion. The binocular cameras are calibrated with Zhang Zhengyou's method. In order to improve the 3D reconstruction speed, a suspicious region is firstly determined by background difference method of a single camera's image sequences. The image rectification, stereo matching and 3D reconstruction process are only executed when there is a suspicious region. A transformation matrix from Camera Coordinate System(CCS) to Track Coordinate System(TCS) is computed with gauge constant and used to transfer the 3D point clouds into the TCS, then the 3D point clouds are used to calculate the object position and intrusion in TCS. The experiments in railway scene show that the position precision is better than 10mm. It is an effective way for clearance intrusion detection and can satisfy the requirement of railway application.

  2. Losses and blade tip clearance for a centrifugal compressor

    Directory of Open Access Journals (Sweden)

    Oana DUMITRESCU

    2018-06-01

    Full Text Available The present paper presents the numerical analysis for a transonic centrifugal compressor using steady state CFD. The blade tip clearance effect over the position of shock waves, tip losses and the performances of the impeller are studied. Numerical simulations have been performed using RANS modelling, with the k-omega SST turbulence model (Shear Stress Transport. Eight cases were taken into consideration for the impeller with the following blade tip clearances values: 0 mm, 0.1 mm, 0.3 mm, 0.4 mm, 0.5mm, 0.7 mm, 1 mm, 2 mm, at the same operating conditions. For the entire stage only seven cases were studied, without the value for 0.1 mm because of its abnormal behaviour, as can be seen in the case of the impeller simulations. Results showed that the position of the shock wave does not change with the increase of the tip clearance. Aerodynamic losses due to shock wave, secondary flow and turbulence can be seen in the polytropic efficiency of the centrifugal impeller and the difference between the two extreme cases is about 3.2 %.

  3. The provision of clearances accuracy in piston - cylinder mating

    Science.gov (United States)

    Glukhov, V. I.; Shalay, V. V.

    2017-08-01

    The paper is aimed at increasing the quality of the pumping equipment in oil and gas industry. The main purpose of the study is to stabilize maximum values of productivity and durability of the pumping equipment based on the selective assembly of the cylinder-piston kinematic mating by optimization criterion. It is shown that the minimum clearance in the piston-cylinder mating is formed by maximum material dimensions. It is proved that maximum material dimensions are characterized by their own laws of distribution within the tolerance limits for the diameters of the cylinder internal mirror and the outer cylindrical surface of the piston. At that, their dispersion zones should be divided into size groups with a group tolerance equal to half the tolerance for the minimum clearance. The techniques for measuring the material dimensions - the smallest cylinder diameter and the largest piston diameter according to the envelope condition - are developed for sorting them into size groups. Reliable control of the dimensions precision ensures optimal minimum clearances of the piston-cylinder mating in all the size groups of the pumping equipment, necessary for increasing the equipment productivity and durability during the production, operation and repair processes.

  4. Brain-wide pathway for waste clearance captured by contrast-enhanced MRI.

    Science.gov (United States)

    Iliff, Jeffrey J; Lee, Hedok; Yu, Mei; Feng, Tian; Logan, Jean; Nedergaard, Maiken; Benveniste, Helene

    2013-03-01

    The glymphatic system is a recently defined brain-wide paravascular pathway for cerebrospinal fluid (CSF) and interstitial fluid (ISF) exchange that facilitates efficient clearance of solutes and waste from the brain. CSF enters the brain along para-arterial channels to exchange with ISF, which is in turn cleared from the brain along para-venous pathways. Because soluble amyloid β clearance depends on glymphatic pathway function, we proposed that failure of this clearance system contributes to amyloid plaque deposition and Alzheimer's disease progression. Here we provide proof of concept that glymphatic pathway function can be measured using a clinically relevant imaging technique. Dynamic contrast-enhanced MRI was used to visualize CSF-ISF exchange across the rat brain following intrathecal paramagnetic contrast agent administration. Key features of glymphatic pathway function were confirmed, including visualization of para-arterial CSF influx and molecular size-dependent CSF-ISF exchange. Whole-brain imaging allowed the identification of two key influx nodes at the pituitary and pineal gland recesses, while dynamic MRI permitted the definition of simple kinetic parameters to characterize glymphatic CSF-ISF exchange and solute clearance from the brain. We propose that this MRI approach may provide the basis for a wholly new strategy to evaluate Alzheimer's disease susceptibility and progression in the live human brain.

  5. Residual kidney function after donor nephrectomy. Assessment by 99mTc-MAG3-Clearance

    International Nuclear Information System (INIS)

    Hamscho, N.; Doebert, N.; Menzel, C.; Berner, U.; Zaplatnikov, K.; Gruenwald, F.; Wilhelm, A.; Gossmann, J.; Scheuermann, E.H.

    2005-01-01

    Aim: We evaluated the long-term residual renal function after donor nephrectomy using 99m Tc-mercaptoacetyltriglycin (MAG3)-clearance. Donors, methods: Altogether 49 kidney donors were examined using 99m Tc-MAG3-clearance after nephrectomy for donation to a relative (m:f=11.38; age 55±27 years). The donors were examined 16±8 years postoperatively (1.5-26 years). 42 donors (86%) showed normal creatinine values, whereas the other seven (14%) exhibited slightly elevated levels. 20 donors were examined pre- and postoperatively and compared intraindividually. The kidney function was compared to the age adapted normal values of healthy persons with two kidneys (67-133% of age related mean). Results: After nephrectomy all donors showed a normal perfusion, good secretion, merely physiological intrarenal transit and a normal elimination from the kidneys. The 99m Tc-MAG3-clearance was 69±15% of the normal mean value of healthy carriers of two kidneys regardless of the gender. 20 donors with a preoperative examination showed a significantly reduced total renal function from 84±15% of the mean normal value preoperatively to 60±15% postoperatively (p 99m Tc-MAG3-clearance measured prior to nephrectomy and the clearance levels after nephrectomy. Also, no correlation between the preoperative 99m Tc-MAG3-clearance and the postoperative serum creatinine values could be observed. Althogether, 22% of the donors (11/49) developed arterial hypertension 10±8 years after donation (1-23 years). This corresponds to the normal age prevalence of hypertension in the carriers of two kidneys. Three donors suffered from arterial hypertension prior to the operation. Conclusion: Kidney donors with normal or slightly elevated creatinine values postoperatively show a 99m Tc-MAG3 clearance value of 69% of the mean value of healthy carriers of two kidneys. This may serve as a reference value for healthy carriers of one kidney. In our study we demonstrated a good compensation of the contralateral

  6. Polyethylene Glycol Modified, Cross-Linked Starch Coated Iron Oxide Nanoparticles for Enhanced Magnetic Tumor Targeting

    Science.gov (United States)

    Cole, Adam J.; David, Allan E.; Wang, Jianxin; Galbán, Craig J.; Hill, Hannah L.; Yang, Victor C.

    2010-01-01

    While successful magnetic tumor targeting of iron oxide nanoparticles has been achieved in a number of models, the rapid blood clearance of magnetically suitable particles by the reticuloendothelial system (RES) limits their availability for targeting. This work aimed to develop a long-circulating magnetic iron oxide nanoparticle (MNP) platform capable of sustained tumor exposure via the circulation and, thus, enhanced magnetic tumor targeting. Aminated, cross-linked starch (DN) and aminosilane (A) coated MNPs were successfully modified with 5 kDa (A5, D5) or 20 kDa (A20, D20) polyethylene glycol (PEG) chains using simple N-Hydroxysuccinimide (NHS) chemistry and characterized. Identical PEG-weight analogues between platforms (A5 & D5, A20 & D20) were similar in size (140–190 nm) and relative PEG labeling (1.5% of surface amines – A5/D5, 0.4% – A20/D20), with all PEG-MNPs possessing magnetization properties suitable for magnetic targeting. Candidate PEG-MNPs were studied in RES simulations in vitro to predict long-circulating character. D5 and D20 performed best showing sustained size stability in cell culture medium at 37°C and 7 (D20) to 10 (D5) fold less uptake in RAW264.7 macrophages when compared to previously targeted, unmodified starch MNPs (D). Observations in vitro were validated in vivo, with D5 (7.29 hr) and D20 (11.75 hr) showing much longer half-lives than D (0.12 hr). Improved plasma stability enhanced tumor MNP exposure 100 (D5) to 150 (D20) fold as measured by plasma AUC0-∞ Sustained tumor exposure over 24 hours was visually confirmed in a 9L-glioma rat model (12 mg Fe/kg) using magnetic resonance imaging (MRI). Findings indicate that both D5 and D20 are promising MNP platforms for enhanced magnetic tumor targeting, warranting further study in tumor models. PMID:21176955

  7. Intra-operative colloid administration increases the clearance of a post-operative fluid load

    DEFF Research Database (Denmark)

    Borup, Tine; Hahn, Robert; Holte, K

    2009-01-01

    using volume kinetics based on the plasma dilution alone. The pre-operative plasma clearance was compared with the post-operative plasma clearance and patients served as their own control. RESULTS: The urinary excretion averaged 350 ml for the pre-operative infusion and 612 ml post-operatively, which...

  8. 76 FR 20967 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-04-14

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  9. Clearance rate of Mytilus edulis (L.) as a function of current velocity and mussel aggregation

    DEFF Research Database (Denmark)

    Nielsen, Pernille; Vismann, Bent

    2014-01-01

    by current velocities up to 1.4 m/sec, whereas experiments with 3 mussels showed that clearance of the mussels decreased progressively at current velocities greater than 0.2 m/sec, and reached 0 L/h per individual at current velocities greater than 0.6 m/sec. The constant feeding at all current velocities......The aim of the current study was to investigate the effect of water current velocities on the clearance rate of Mytilus edulis when different numbers of mussels were used in the experiments. An automatic setup, which controlled and monitored the algal concentration continually, was used to measure...... the effect of increasing current velocity (0.05-1.4 m/sec) on the M. edulis clearance rate. Clearance rate measurements were performed under constant food concentrations of 3,000 cells/mL of Rhodomonas salina on either 3 mussels or 20 mussels. We found that the clearance rate of 20 mussels was unaffected...

  10. Step responses of a torsional system with multiple clearances: Study of vibro-impact phenomenon using experimental and computational methods

    Science.gov (United States)

    Oruganti, Pradeep Sharma; Krak, Michael D.; Singh, Rajendra

    2018-01-01

    Recently Krak and Singh (2017) proposed a scientific experiment that examined vibro-impacts in a torsional system under a step down excitation and provided preliminary measurements and limited non-linear model studies. A major goal of this article is to extend the prior work with a focus on the examination of vibro-impact phenomena observed under step responses in a torsional system with one, two or three controlled clearances. First, new measurements are made at several locations with a higher sampling frequency. Measured angular accelerations are examined in both time and time-frequency domains. Minimal order non-linear models of the experiment are successfully constructed, using piecewise linear stiffness and Coulomb friction elements; eight cases of the generic system are examined though only three are experimentally studied. Measured and predicted responses for single and dual clearance configurations exhibit double sided impacts and time varying periods suggest softening trends under the step down torque. Non-linear models are experimentally validated by comparing results with new measurements and with those previously reported. Several metrics are utilized to quantify and compare the measured and predicted responses (including peak to peak accelerations). Eigensolutions and step responses of the corresponding linearized models are utilized to better understand the nature of the non-linear dynamic system. Finally, the effect of step amplitude on the non-linear responses is examined for several configurations, and hardening trends are observed in the torsional system with three clearances.

  11. Effect of increased surface hydrophobicity via drug conjugation on the clearance of inhaled PEGylated polylysine dendrimers.

    Science.gov (United States)

    Haque, Shadabul; McLeod, Victoria M; Jones, Seth; Fung, Sandy; Whittaker, Michael; McIntosh, Michelle; Pouton, Colin; Owen, David J; Porter, Christopher J H; Kaminskas, Lisa M

    2017-10-01

    PEGylated polylysine dendrimers are attractive and well tolerated inhalable drug delivery platforms that have the potential to control the release, absorption kinetics and lung retention time of conjugated drugs. The clinical application of these systems though, would likely require partial substitution of surface PEG groups with drug molecules that are anticipated to alter their lung clearance kinetics and clearance pathways. In the current study, we therefore evaluated the impact of increased surface hydrophobicity via substitution of 50% surface PEG groups with a model hydrophobic drug (α-carboxyl OtButylated methotrexate) on the lung clearance of a Generation 5 PEGylated polylysine dendrimer in rats. PEG substitution with OtBu-methotrexate accelerated lung clearance of the dendrimer by increasing polylysine scaffold catabolism, improving systemic absorption of the intact dendrimer and low molecular weight products of scaffold catabolism, and enhancing mucociliary clearance. These results suggest that the conjugation of hydrophobic drug on the surface of a PEGylated dendrimer is likely to accelerate lung clearance when compared to a fully PEGylated dendrimer. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  12. Using radioaerosols to monitor physiotherapy-enhanced mucus clearance at different levels of the bronchial tree

    International Nuclear Information System (INIS)

    Hasani, A.; Pavia, D.; Clarke, S.W.; Agnew, J.E.

    1993-01-01

    Patients with airways obstruction often find it difficult to clear excess lung secretions. Frequent coughing can clear the larger airways but may itself further damage the airways ciliated epithelium. Various physiotherapy regimes have been proposed yet objective evidence of their efficacy is sparse. Deposited aerosol particles - with an appropriate label for gamma imaging - can track clearance from different lung regions. Published reports have however tended to be equivocal in respect of clearance from the more distal conducting airways. Questions also arise as to coordination of transport rates at different levels of the bronchial tree. We therefore sought to re-assess requirements for effective analysis of physiotherapy-enhanced clearance to yield data on both peripheral and central airways clearance. (author)

  13. Using radioaerosols to monitor physiotherapy-enhanced mucus clearance at different levels of the bronchial tree

    Energy Technology Data Exchange (ETDEWEB)

    Hasani, A.; Pavia, D.; Clarke, S.W.; Agnew, J.E. (Royal Free Hospital, London (United Kingdom))

    1993-01-01

    Patients with airways obstruction often find it difficult to clear excess lung secretions. Frequent coughing can clear the larger airways but may itself further damage the airways ciliated epithelium. Various physiotherapy regimes have been proposed yet objective evidence of their efficacy is sparse. Deposited aerosol particles - with an appropriate label for gamma imaging - can track clearance from different lung regions. Published reports have however tended to be equivocal in respect of clearance from the more distal conducting airways. Questions also arise as to coordination of transport rates at different levels of the bronchial tree. We therefore sought to re-assess requirements for effective analysis of physiotherapy-enhanced clearance to yield data on both peripheral and central airways clearance. (author).

  14. Binding and clearance of Tc-99m pyrophosphate from the lungs of smokers and nonsmokers

    International Nuclear Information System (INIS)

    Isitman, A.T.; Effros, R.; Collier, B.D.; Palmer, D.W.; Krasnow, A.Z.; Hellman, R.S.; Hacker, A.; Berger, C.; Trembath, L.

    1990-01-01

    Both acute and chronic lung disorders that affect the alveolar epithelium increase the rate at which aerosolized Tc-99 m DTPA is cleared from the lungs. Transalveolar clearance of Tc-99 DTPA has been used to detect lung injury, but- because smokers have a much faster clearance rate of Tc-99m DTPA-this examination has been limited primarily to nonsmokers. The purpose of this paper is to determine if the clearance of a larger molecule, Tc-99m PYP (molecular weight by ultrafiltration between 1.000 and 3,000 daltons), is also accelerated by smoking. Clearances of each indicator were studies for 6 hours in eight normal nonsmoking subjects and seven (otherwise normal smokers)

  15. Four hour creatinine clearance is better than plasma creatinine for monitoring renal function in critically ill patients

    Science.gov (United States)

    2012-01-01

    Introduction Acute kidney injury (AKI) diagnosis is based on an increase in plasma creatinine, which is a slowly changing surrogate of decreased glomerular filtration rate. We investigated whether serial creatinine clearance, a direct measure of the glomerular filtration rate, provided more timely and accurate information on renal function than serial plasma creatinine in critically ill patients. Methods Serial plasma creatinine and 4-hour creatinine clearance were measured 12-hourly for 24 hours and then daily in 484 patients. AKI was defined either as > 50% increase in plasma creatinine from baseline, or > 33.3% decrease in creatinine clearance. The diagnostic and predictive performance of the two AKI definitions were compared. Results Creatinine clearance decrease diagnosed AKI in 24% of those not diagnosed by plasma creatinine increase on entry. These patients entered the ICU sooner after insult than those diagnosed with AKI by plasma creatinine elevation (P = 0.0041). Mortality and dialysis requirement increased with the change in creatinine clearance-acute kidney injury severity class (P = 0.0021). Amongst patients with plasma creatinine creatinine clearance improved the prediction of AKI considerably (Net Reclassification Improvement 83%, Integrated Discrimination Improvement 0.29). On-entry, creatinine clearance associated with AKI severity and duration (P 33.3% decrease in creatinine clearance over the first 12 hours was associated with a 2.0-fold increased relative risk of dialysis or death. Conclusions Repeated 4-hour creatinine clearance measurements in critically ill patients allow earlier detection of AKI, as well as progression and recovery compared to plasma creatinine. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN012606000032550. PMID:22713519

  16. Identification of Clearance and Contact Stiffness in a Simplified Barrel-Cradle Structure of Artillery System

    Directory of Open Access Journals (Sweden)

    Bing Li

    2015-02-01

    Full Text Available In gun barrel-cradle structure, the presence of clearance usually changes the dynamic response of muzzle and results in shooting dispersion (under continuous firing condition. The parameter estimation of such clearance nonlinear system is the prerequisite for establishing quantitative relation between the clearance and muzzle disturbance. In this paper, the restoring force surface (RFS method and the nonlinear identification through feedback of outputs (NIFO method are first combined for parameter identification in a simplified barrel-cradle structure. With the RFS method, clearance value can be obtained by analyzing the restoring force plot. Then the contact stiffness can be identified by using NIFO method. This identification process is verified in a single-degree-of-freedom (SDOF system with clearance. To adapt to the rigid-flexible coupled beam system with clearances which is simplified from the barrel-cradle structure, a modification for the combined method mentioned above is proposed. The core idea of the modification is reducing the continuous system to multiple-degree-of-freedom (MDOF system to reserve the nonlinear characteristics through modal transformation matrix. The advantage of this transformation is that the linear parts of the MDOF systems are decoupled, which greatly reduces the difficulty of identification. The simulation results have shown the effectiveness of current method.

  17. Comparative study of conventional PAH and inulin clearance and slope clearance of 131I-o-hippuric acid and 51Cr-EDTA

    International Nuclear Information System (INIS)

    Berghaeuser, H.

    1981-01-01

    ''Classic'' PAH and inulin clearance were determined in 81 patients with renal anomalies or renal diseases of different genesis and severity. In addition, radioisotope nephrography was carried out after administration of I-131-o-hippuric acid, followed by administration of Cr-51-EDTA. The activity decrease was recorded by a sensor located over the patient's right shoulder; the activities of a serum sample and of the urine excreted after 21 or 31 min were measured, and the findings were compared with those of the classic method. The clearance data calculated on the basis of the soulder measurements were hardly compatible with those of the conventional method in the case of 131 I-o-hippuric acid (r=0.54) and totally incompatible in the case of 51 Cr-EDTA. This means that the method described by Oberhausen is the only accurate method available for a quantitative assessment of the renal function on the basis of measurements of the activity decrease in the body. The activity of urine excreted after 31 min ( 131 I-hippuric acid:r=0.992, 51 Cr-EDTA:r=0.79) is a sufficiently accurate parameter although it is inaccurate at PAH clearance, values > 130 ml/min and inulin clearance values > 30 ml/min. Of the many parameters of radioisotope nephrogram curves, in the case of 131 I-o-hippuric acid only the parameters related to the ascent between 48 and 120 sec or to the secant ascent yield sufficient quantitative information for certain functional regions (r=0.9 resp. r=0.93). In the case of 51 Cr-EDTA, semiquantitative information on the renal function can be obtained by constructing secants on the nephrogram curves (r=0.7 resp. r=0.72). Here as in the case of 131 I-hippuric acid, the contribution of each kidney can be determined individually from the functional analysis of both kidneys. (orig.) [de

  18. Control of internal packing seal clearances considering for shaft behavior during steam turbine operation

    Energy Technology Data Exchange (ETDEWEB)

    Pack, Min Sik; Lee, Si Yeon; Choi, Sung Choul; Lee, Jae Geun [Korea Plant Service and Engineering Co., Ltd., Seongnam (Korea, Republic of); Yang, Bo Suk [Pukyong National Univ., Busan (Korea, Republic of)

    2004-07-01

    This paper presents the characteristics of internal clearances for the interstage of blades and shaft gland seals on the steam turbine which are installed in tandem compound. Internal clearances was changed when the rotor turned in the cylindrical sleeve bearing due to the generation of oil film wedge. This presented concern is very useful to prevent the rubbing damage of seal edge between the fixed and moving parts in steam turbine due to the misalignment at the rotating and stationary parts. This method is applied for the unbalanced clearances distribution to the left and right sides in the turbine casing. A considerable amount of unbalanced clearances distribution trend is determined according to the rotating speed of rotor, size and type of journal bearing, oil viscosity, surface roughness of bearing and shaft, oil temperature, oil pressure and bearing load.

  19. Effects of cigarette smoking on I-123 IMP clearance from the lung

    International Nuclear Information System (INIS)

    Katoh, Kunihiko; Takahashi, Tsuneo

    1990-01-01

    N-isopropyl-p-I-123-iodoamphetamine (I-123 IMP), originally developed as a brain scanning agent, is also taken up by the lung. To evaluate the cigarette smoking on the uptake of IMP by the lung, we studied I-123 IMP clearance from the lung on 14 volunteers; 5 non-smokers and 9 smokers. After the injection of 111 MBq (3mCi) of I-123 IMP into the medial cubital vein, the time-activity curve for 60 minutes and the regional activity using 1 frame per minute and a 64 x 64 matrix was obtained. I-123 IMP clearance curve was described as follows: C(t)=A 1 e -k1t +A 2 e -k2t (A 1 , A 2 : intercepts, and k 1 , k 2 : slopes of the exponential components). I-123 IMP clearance was delayed in smokers, and k 2 was smaller in smokers. Also a significant correlations between k 1 , k 2 , and the number of cigarettes smoked per day were found. In conclusion, this study suggests that the delayed clearance and retention of I-123 IMP in the lung indicate the lung metabolic disorders due to cigarette smoking. (author)

  20. Effect of Guide Vane Clearance Gap on Francis Turbine Performance

    Directory of Open Access Journals (Sweden)

    Ravi Koirala

    2016-04-01

    Full Text Available Francis turbine guide vanes have pivoted support with external control mechanism, for conversion of pressure to kinetic energy and to direct them to runner vanes. This movement along the support is dependent on variation of load and flow (operating conditions. Small clearance gaps between facing plates and the upper and lower guide vane tips are available to aid this movement, through which leakage flow occurs. This secondary flow disturbs the main flow stream, resulting performance loss. Additionally, these increased horseshoe vortex, in presence of sand, when crosses through the gaps, both the surfaces are eroded. This causes further serious effect on performance and structural property by increasing gaps. This paper discusses the observation of the severity in hydropower plants and effect of clearance gaps on general performance of the Francis turbine through computational methods. It also relates the primary result with the empirical relation for leakage flow prediction. Additionally, a possible method to computationally estimate thickness depletion has also been presented. With increasing clearance gap, leakage increases, which lowers energy conversion and turbine efficiency along with larger secondary vortex.

  1. Impairment of aminopyrine clearance in aspirin-damaged canine gastric mucosa

    International Nuclear Information System (INIS)

    Miller, T.A.; Henagan, J.M.; Loy, T.M.

    1983-01-01

    Using an in vivo canine chambered stomach preparation, the clearance of [ 14 C]aminopyrine across mucosa when intravenously infused and the back-diffusion of this substance from gastric lumen to mucosa when topically applied to gastric epithelium were evaluated in aspirin-damaged gastric epithelium. In mucosa damaged by either 20 mM or 40 mM aspirin, the recovery of [ 14 C]aminopyrine, when topically mixed with acid (pH . 1.1) perfusate solution, was not significantly different from nondamaged control mucosa. In addition, the degree of ''trapping'' of this substance from back-diffusion was not different in damaged mucosa from that observed in nondamaged epithelium. In contrast, when [ 14 C]aminopyrine was intravenously infused, its clearance was significantly impaired in aspirin-damaged mucosa when compared with control studies, as evidenced by the increased ''trapping'' of this substance in injured epithelium. These findings indicate that movement of aminopyrine from plasma to gastric lumen is impaired in damaged epithelium, making the aminopyrine clearance technique an unreliable method to accurately measure absolute gastric blood flow in this experimental setting

  2. Numerical investigation of tip clearance cavitation in Kaplan runners

    Science.gov (United States)

    Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.

    2016-11-01

    There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.

  3. 14 CFR 99.17 - Deviation from flight plans and ATC clearances and instructions.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Deviation from flight plans and ATC clearances and instructions. 99.17 Section 99.17 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... TRAFFIC General § 99.17 Deviation from flight plans and ATC clearances and instructions. (a) No pilot may...

  4. Frequency of stone clearance after extracorporeal shockwave ...

    African Journals Online (AJOL)

    Objective: To determine the rate of stone clearance after extracorporeal shockwave lithotripsy (ESWL) for renal stones in adult patients with renal insufficiency. Subjects and methods: This is a cross-sectional descriptive study of 117 adult patients who underwent ESWL. The indications for ESWL were determined by the ...

  5. Correlates of spontaneous clearance of hepatitis C virus in a Danish human immunodeficiency virus type 1 cohort

    DEFF Research Database (Denmark)

    Clausen, Louise Nygaard; Weis, Nina; Schønning, Kristian

    2011-01-01

    ) 18-28) had cleared their HCV infection and 251 (77%; 95% CI 72-82) had a chronic infection. The clearance rate in HBsAg-positive individuals was 65%. Being female, HBsAg-positive, or belonging to HIV exposure groups IDU and MSM predicted higher HCV clearance rates (adjusted odds ratio (aOR) 1.8, 95......% CI 1-3.2; aOR 7.6, 95% CI 2.7-21; aOR 5.2, 1.2-23.5; and aOR 10.2, 95% CI 1.8-58, respectively). Race, acquired immunodeficiency syndrome (AIDS), and antiretroviral therapy were not associated with HCV clearance. Conclusions: The HCV clearance rate in this HIV-1 cohort was 23%. MSM and IDUs may have......Abstract Background: Around a quarter of individuals infected with hepatitis C virus (HCV) are spontaneously able to clear the virus. Correlates of spontaneous HCV clearance are not well established and the aim of this study was to characterize factors associated with spontaneous HCV clearance...

  6. Hepatic and muscle clearance of physostigmine in the rat after i.v. administration

    International Nuclear Information System (INIS)

    Somani, S.M.; Unni, L.K.

    1986-01-01

    This study presents a method to calculate the extraction ratio (ER) from in vivo time course of liver metabolism using the physiological and pharmacokinetic parameters such as plasma flow rate, partition coefficient of drug between tissue and plasma and the elimination rate constant from tissues. Rats were administered 3 H-physostigmine (Phy), 100 μg/kg i.v.; and were sacrificed at various times. Tissues were removed and Phy and its metabolites were determined by HPLC. Half-life of Phy in liver and muscle was 24 and 20 min, respectively. ER of Phy in liver was .71 which showed a slight decrease at 10 min. Muscle ER was found to be .347 up to 5 min. Hepatic clearance was calculated to be 23.08 ml/min/kg (34.9% of systemic clearance) and the intrinsic clearance was 83.73 ml/min/kg which indicates that the changes in blood flow to the liver can cause a variation in the systematic clearance. Percentage dose of Phy retained in muscle was maximum and the clearance was 5.2 ml/min/kg suggesting that muscle might be acting as a storage depot for Phy prolonging the pharmacological effects. About 30-40% of radioactivity in the liver could not be washed off by 10% TCA or organic solvents indicating the irreversible binding of drug or metabolite to liver macromolecule

  7. Quantitative static scintigraphy for the evaluation of mucociliary clearance

    International Nuclear Information System (INIS)

    Maini, C.L.; Marchetti, L.; Giordano, A.; Antonelli Incalzi, R.; Fuso, L.

    1988-01-01

    Mucociliary clearance can be evaluated by radionuclide techniques, but such approaches have been usually implemented only in research-oriented laboratories because of technical difficulties. A very practical radionuclide method is here presented which requires only three static acquisitions after the inhalation of a polydisperse radioaerosol produced by a commercial generator. Data processing is also very simple. The diagnostic performance of the method was tested on a study population of 10 healthy subjects and 10 patients with athrophic bronchitis; a higly significance difference between normal and pathological patients was found. Its simple implementation and diagnostic yield recommend this radionuclide method for the routine assessment of mucociliary clearance also in busy clinical-oriented laboratories

  8. Sulfadoxine-pyrimethamine monotherapy in Tanzanian children gives rapid parasite clearance but slow fever clearance that is improved by chloroquine in combination therapy

    DEFF Research Database (Denmark)

    Tarimo, D S; Minjas, J N; Bygbjerg, I C

    2002-01-01

    Following widespread chloroquine (CQ) resistance, sulfadoxine plus pyrimethamine (SP) is now the first line antimalarial drug in a number of African countries including Tanzania. Unlike CQ, SP has no antipyretic effects, a feature that might delay fever clearance, and by acting on late stage para...... on possible delayed parasitological and clinical responses to SP that could result from its action on late stage parasites. Despite its diminishing antimalarial activity, CQ has beneficial in vivo antipyretic effects in therapeutic combination with SP.......Following widespread chloroquine (CQ) resistance, sulfadoxine plus pyrimethamine (SP) is now the first line antimalarial drug in a number of African countries including Tanzania. Unlike CQ, SP has no antipyretic effects, a feature that might delay fever clearance, and by acting on late stage...

  9. Clearance rates of jellyfish and their potential predation impact on zooplankton and fish larvae in a neritic ecosystem (Limfjorden, Denmark)

    DEFF Research Database (Denmark)

    Hansson, L. J.; Moeslund, O.; Kiørboe, Thomas

    2005-01-01

    clearance potential were given assumed clearance rate values, but the collective predation potential by these species was evaluated to be small. Hydromedusae dominated numerically and had their highest potential clearance impact in spring, but overall jellyfish clearance potential on copepods was low during...

  10. RENAL CLEARANCE AND URINARY EXCRETION OF CIPROFLOXACIN IN GOATS

    Directory of Open Access Journals (Sweden)

    Z. IQBAL, I. JAVED, B. ASLAM, F. MUHAMMAD AND I. U. JAN

    2007-10-01

    Full Text Available The renal clearance and urinary excretion of ciprofloxacin were investigated in eight healthy female goats. In each animal, ciprofloxacin was administered intramuscularly at the rate of 5 mg/kg body weight. Following drug administration, blood and urine samples were collected at different time intervals and analyzed for ciprofloxacin and creatinine. High performance liquid chromatography (HPLC was used to determine the drug concentration in the plasma and urine. The value of diuresis after single administration of ciprofloxacin was 0.073 ± 0.014 ml/min/kg. Mean (± SE values for renal clearance of creatinine and ciprofloxacin were 1.870 ± 0.385 and 0.982 ± 0.166 ml/min/kg, respectively. The ratio between the renal clearance of ciprofloxacin and that of creatinine remained less than one, which was indicative of back diffusion. The mean (± SE value for the cumulative percent of ciprofloxacin dose excreted at 10 hours following its intramuscular administration was 13.03 ± 2.07. Based on these results, it was evident that besides glomerular filtration, renal handling of drug involved back diffusion also. It was concluded that in local goats glomerular filtration rate (GFR was lower than that reported for their foreign counterparts.

  11. LRP1 in Brain Vascular Smooth Muscle Cells Mediates Local Clearance of Alzheimer's Amyloid-β

    OpenAIRE

    Kanekiyo, Takahisa; Liu, Chia-Chen; Shinohara, Mitsuru; Li, Jie; Bu, Guojun

    2012-01-01

    Impaired clearance of amyloid-β (Aβ) is a major pathogenic event for Alzheimer’s disease (AD). Aβ depositions in brain parenchyma as senile plaques and along cerebrovasculature as cerebral amyloid angiopathy (CAA) are hallmarks of AD. A major pathway that mediates brain Aβ clearance is the cerebrovascular system where Aβ is eliminated through the blood-brain barrier (BBB) and/or degraded by cerebrovascular cells along the interstitial fluid drainage pathway. An Aβ clearance receptor, the low-...

  12. CGRP as the target of new migraine therapies - successful translation from bench to clinic.

    Science.gov (United States)

    Edvinsson, Lars; Haanes, Kristian Agmund; Warfvinge, Karin; Krause, Diana N

    2018-06-01

    Treatment of migraine is on the cusp of a new era with the development of drugs that target the trigeminal sensory neuropeptide calcitonin gene-related peptide (CGRP) or its receptor. Several of these drugs are expected to receive approval for use in migraine headache in 2018 and 2019. CGRP-related therapies offer considerable improvements over existing drugs as they are the first to be designed specifically to act on the trigeminal pain system, they are more specific and they seem to have few or no adverse effects. CGRP receptor antagonists such as ubrogepant are effective for acute relief of migraine headache, whereas monoclonal antibodies against CGRP (eptinezumab, fremanezumab and galcanezumab) or the CGRP receptor (erenumab) effectively prevent migraine attacks. As these drugs come into clinical use, we provide an overview of knowledge that has led to successful development of these drugs. We describe the biology of CGRP signalling, summarize key clinical evidence for the role of CGRP in migraine headache, including the efficacy of CGRP-targeted treatment, and synthesize what is known about the role of CGRP in the trigeminovascular system. Finally, we consider how the latest findings provide new insight into the central role of the trigeminal ganglion in the pathophysiology of migraine.

  13. Bronchoscintigraphy and pulmonary clearance of 99mTc-albumin colloid in study of mucociliary clearance

    International Nuclear Information System (INIS)

    Mortensen, Jann

    1998-01-01

    A radioaerosol based method for measuring MC was introduced. It included an inhalation protocol that resulted in a predominant deposition of radioaerosol in the central bronchi and two simple procedures of evaluation: 1) a visual semi-quantitative bronchoscintigraphic analysis, and 2) a quantitative analysis of the retention of the radioactivity at different points after the inhalation. The results showed that bronchoscintigraphy was a simple technique that may be used to visualize a stimulation of mucociliary transport in the central airways of individuals that do not suffer from too much mucus hypersecretion. Comparison of the MC between individuals, however, should preferably be performed by the method of quantitative analysis of the radioactivity disappearance. A change of MC was found to be one of the first detectable effects on lung function of tobacco smoking. It could be effectively detected by measurement of radioaerosol clearance both by bronchoscintigraphy and simple quantification of the MC. The MC may be either acutely enhanced, reduced or not changed by smoking. Long-term smoking impairs MC. The enhancement of MC by β 2 -agonists was very limited in most patients with CF. In the hope of increasing mucus transport in patients with CF, these are treated with various chest physiotherapy techniques. The radioaerosol based method of measurement of MC could assess mucus clearance by chest physiotherapy and cough. (au)

  14. Tip Clearance Control Using Plasma Actuators

    Science.gov (United States)

    2007-03-01

    Clearance Control Using Plasma Actuators 4 posed by Denton (1993). A number of investigators have used partial shrouds, or " winglet " designs to...SDBD actuator Plasma enhanced aerodynamics has been demonstrated in a range of applications involving sepa- ration control, lift enhancement, drag... aerodynamic benefits of a squealer tip geometry. Specifically, the squealer tip is known to reduce the discharge coefficient of the tip gap, thereby

  15. U.S. nuclear fuel cycle regulatory issues on exclusion, exemption, and clearance

    International Nuclear Information System (INIS)

    Meck, R.A.

    1997-01-01

    The U.S. Nuclear Regulatory Commission is considering the use of exclusion and clearance in connection with the nuclear fuel cycle regulations. Clearance of licensed lands, buildings, structures, materials, and equipment could expose members of the public to radiation in addition to background. Establishing and implementing dose criteria for allowed concentrations of radioactivity in the various media raise challenging issues for the regulator. Clearance also raises significant regulatory issues, and these issues reflect trade-offs between concerns for protecting public health and safety, as well as other socioeconomic values and concerns. At the heart of the issues are the adequacy of risk analyses, acceptability of risks, underlying rationales, feasibility and cost of implementation, and exposures of the public to man-made radiation in relation to natural sources of radiation. (author)

  16. 76 FR 13020 - Agency Information Collection Activities: Comment Request; Generic Clearance for the Collection...

    Science.gov (United States)

    2011-03-09

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  17. Assessments of risk following the inhalation of plutonium oxide using observed lung clearance patterns

    International Nuclear Information System (INIS)

    Ramsden, D.

    1977-10-01

    Dose commitments and risk estimates for the inhalation of plutonium oxide are calculated using the lung clearance patterns observed at AEE Winfrith. These risks are compared with published data on risks arising from a lung clearance based on the ICRP Lung Model. (author)

  18. Erythrocyte Saturation with IgG Is Required for Inducing Antibody-Mediated Immune Suppression and Impacts Both Erythrocyte Clearance and Antigen-Modulation Mechanisms.

    Science.gov (United States)

    Cruz-Leal, Yoelys; Marjoram, Danielle; Lazarus, Alan H

    2018-02-15

    Anti-D prevents hemolytic disease of the fetus and newborn, and this mechanism has been referred to as Ab-mediated immune suppression (AMIS). Anti-D, as well as other polyclonal AMIS-inducing Abs, most often induce both epitope masking and erythrocyte clearance mechanisms. We have previously observed that some Abs that successfully induce AMIS effects could be split into those that mediate epitope masking versus those that induce erythrocyte clearance, allowing the ability to analyze these mechanisms separately. In addition, AMIS-inducing activity has recently been shown to induce Ag modulation (Ag loss from the erythrocyte surface). To assess these mechanisms, we immunized mice with transgenic murine RBCs expressing a single Ag protein comprising a recombinant Ag composed of hen egg lysozyme, OVA sequences comprising aa 251-349, and the human Duffy transmembrane protein (HOD-Ag) with serial doses of polyclonal anti-OVA IgG as the AMIS-inducing Ab. The anti-OVA Ab induced AMIS in the absence of apparent epitope masking. AMIS occurred only when the erythrocytes appeared saturated with IgG. This Ab was capable of inducing HOD-RBC clearance, as well as loss of the OVA epitope at doses of Ab that caused AMIS effects. HOD-RBCs also lost reactivity with Abs specific for the hen egg lysozyme and Duffy portions of the Ag consistent with the initiation of Ag modulation and/or trogocytosis mechanisms. These data support the concept that an AMIS-inducing Ab that does not cause epitope masking can induce AMIS effects in a manner consistent with RBC clearance and/or Ag modulation. Copyright © 2018 by The American Association of Immunologists, Inc.

  19. 51Cr-EDTA plasma clearance in severe renal failure determined by one plasma sample

    DEFF Research Database (Denmark)

    Kamper, A L; Nielsen, S L

    1989-01-01

    Two hundred and thirty-four measurements of standard 51Cr-EDTA plasma clearance were made in 50 patients with severe chronic renal failure. Based on these data two calculation methods were attempted using one plasma sample drawn 24 h after injection of 51Cr-EDTA. One of the methods used the 'one...... at zero-time was derived from injected dose and body surface area. This method might provide values 1.5 ml/min below or 0.8 ml/min above the established method of 51Cr-EDTA plasma clearance, which would be acceptable for clinical purposes. It is concluded that exact plasma clearance of 51Cr-EDTA in severe...... renal dysfunction (estimated clearance values below 21 ml/min) may be determined with adequate precision by one plasma sample drawn at 24 h after injection of the tracer without sampling at 5 h. This appears to be a very practical simplification....

  20. Oral sugar clearance and root caries prevalence in rheumatic patients with dry mouth symptoms.

    Science.gov (United States)

    Risheim, H; Arneberg, P; Birkhed, D

    1992-01-01

    The relationship between root caries, oral sugar clearance, salivary flow rate, and salivary counts of mutans streptococci, lactobacilli and candida has been studied in a group of 22 rheumatic patients (age range 40-72 years). The study group comprised all subjects volunteering for a clinical trial on relief of dry mouth symptoms. The median salivary flow was 0.09 ml/min at rest and 0.9 ml/min during chewing stimulation. The median sugar clearance time was about 5 min in the sublingual area and 16 min in the lower buccal vestibule. For subjects with 0-2 root caries lesions the clearance time at both sites was shorter than for subjects with 3 or more lesions (p flow, and high salivary counts of mutans streptococci. It is concluded that root caries in rheumatic patients with low salivary flow is significantly related to oral sugar clearance time.

  1. 48 CFR 16.403-2 - Fixed-price incentive (successive targets) contracts.

    Science.gov (United States)

    2010-10-01

    ... target cost plus the firm target profit as a guide. (ii) If negotiation of a firm fixed price is... pricing information is not sufficient to permit the negotiation of a realistic firm target cost and profit...; and (2) Cost or pricing information adequate for establishing a reasonable firm target cost is...

  2. Blood lactate clearance after maximal exercise depends on active recovery intensity.

    Science.gov (United States)

    Devlin, J; Paton, B; Poole, L; Sun, W; Ferguson, C; Wilson, J; Kemi, O J

    2014-06-01

    High-intensity exercise is time-limited by onset of fatigue, marked by accumulation of blood lactate. This is accentuated at maximal, all-out exercise that rapidly accumulates high blood lactate. The optimal active recovery intensity for clearing lactate after such maximal, all-out exercise remains unknown. Thus, we studied the intensity-dependence of lactate clearance during active recovery after maximal exercise. We constructed a standardized maximal, all-out treadmill exercise protocol that predictably lead to voluntary exhaustion and blood lactate concentration>10 mM. Next, subjects ran series of all-out bouts that increased blood lactate concentration to 11.5±0.2 mM, followed by recovery exercises ranging 0% (passive)-100% of the lactate threshold. Repeated measurements showed faster lactate clearance during active versus passive recovery (P40%>passive recovery, Pexercise clears accumulated blood lactate faster than passive recovery in an intensity-dependent manner, with maximum clearance occurring at active recovery of 80% of lactate threshold.

  3. Evaluation of aorto-iliac disease with Doppler ultrasound and isotope clearance techniques

    International Nuclear Information System (INIS)

    Appleberg, M.; Lewis, J.D.

    1975-01-01

    The clearance of 99 mTc from the hamstring muscle compartment of patients with aorto-iliac or iliac disease was examined with the patients at rest and after exercise. The values were compared with those obtained in a group of controls and another group with superficial femoral, or femoropopliteal arterial occlusion. A statistically significant difference in the rate of 99 mTc clearance was found in patients with proximal vascular disease

  4. Dual roles for hepatic lectin receptors in the clearance of chilled platelets

    DEFF Research Database (Denmark)

    Rumjantseva, Viktoria; Grewal, Prabhjit K; Wandall, Hans H

    2009-01-01

    -GlcNAc moieties by galactosylation prevents clearance of short-term-cooled platelets, this strategy is ineffective after prolonged refrigeration. We report here that prolonged refrigeration increased the density and concentration of exposed galactose residues on platelets such that hepatocytes, through Ashwell-Morell...... transfusion. Inhibition of chilled platelet clearance by both beta(2) integrin and Ashwell-Morell receptors may afford a potentially simple method for storing platelets in the cold....

  5. 76 FR 13019 - Agency Information Collection Activities: Comment Request; Generic Clearance for the Collection...

    Science.gov (United States)

    2011-03-09

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  6. 76 FR 37825 - Agency Information Collection Activities; Generic Clearance for the Collection of Qualitative...

    Science.gov (United States)

    2011-06-28

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Activities; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  7. Effect of increases in lung volume on clearance of aerosolized solute from human lungs

    Energy Technology Data Exchange (ETDEWEB)

    Marks, J.D.; Luce, J.M.; Lazar, N.M.; Wu, J.N.; Lipavsky, A.; Murray, J.F.

    1985-10-01

    To study the effect of increases in lung volume on solute uptake, we measured clearance of /sup 99m/Tc-diethylenetriaminepentaacetic acid (Tc-DTPA) at different lung volumes in 19 healthy humans. Seven subjects inhaled aerosols (1 micron activity median aerodynamic diam) at ambient pressure; clearance and functional residual capacity (FRC) were measured at ambient pressure (control) and at increased lung volume produced by positive pressure (12 cmH2O continuous positive airway pressure (CPAP)) or negative pressure (voluntary breathing). Six different subjects inhaled aerosol at ambient pressure; clearance and FRC were measured at ambient pressure and CPAP of 6, 12, and 18 cmH2O pressure. Six additional subjects inhaled aerosol at ambient pressure or at CPAP of 12 cmH2O; clearance and FRC were determined at CPAP of 12 cmH2O. According to the results, Tc-DTPA clearance from human lungs is accelerated exponentially by increases in lung volume, this effect occurs whether lung volume is increased by positive or negative pressure breathing, and the effect is the same whether lung volume is increased during or after aerosol administration. The effect of lung volume must be recognized when interpreting the results of this method.

  8. Effect of increases in lung volume on clearance of aerosolized solute from human lungs

    International Nuclear Information System (INIS)

    Marks, J.D.; Luce, J.M.; Lazar, N.M.; Wu, J.N.; Lipavsky, A.; Murray, J.F.

    1985-01-01

    To study the effect of increases in lung volume on solute uptake, we measured clearance of /sup 99m/Tc-diethylenetriaminepentaacetic acid (Tc-DTPA) at different lung volumes in 19 healthy humans. Seven subjects inhaled aerosols (1 micron activity median aerodynamic diam) at ambient pressure; clearance and functional residual capacity (FRC) were measured at ambient pressure (control) and at increased lung volume produced by positive pressure [12 cmH 2 O continuous positive airway pressure (CPAP)] or negative pressure (voluntary breathing). Six different subjects inhaled aerosol at ambient pressure; clearance and FRC were measured at ambient pressure and CPAP of 6, 12, and 18 cmH 2 O pressure. Six additional subjects inhaled aerosol at ambient pressure or at CPAP of 12 cmH 2 O; clearance and FRC were determined at CPAP of 12 cmH 2 O. According to the results, Tc-DTPA clearance from human lungs is accelerated exponentially by increases in lung volume, this effect occurs whether lung volume is increased by positive or negative pressure breathing, and the effect is the same whether lung volume is increased during or after aerosol administration. The effect of lung volume must be recognized when interpreting the results of this method

  9. Studi Karakteristik Aliran Tiga Dimensi Dan Perpindahan Panas Pada Cascade Airfoil Dengan Pengaruh Clearance

    Directory of Open Access Journals (Sweden)

    Yusuf Wibisono

    2013-03-01

    Full Text Available Dalam dunia teknik khususunya mekanika fluida, aliran tiga dimensi merupakan hal yang sangat penting guna untuk mengetahui fenomena aliran dan perpindahan panas yang terjadi pada bluffbody cascade airfoil. Error atau loses yang terjadi pada cascade airfoil disebabkan oleh adanya aliran sekunder. Error atau loses tersebut menurut penilitian yang terlah dilakukan dapat dikurang dengan aspek clearance. Tujuan dari penilitian ini adalah untuk menganalisa karaktersistik aliran tiga dimensi serta perpindahan panas akibat adanya perubahan jarak antara leading edge antara cascade dan sudut serang serta bentuk geometri. hasil dari simulasi divisualisasikan dalam bentuk velocity dan pressure coefficient. Pada cascade airfoil dengan sudut serang 20° terjadi fenomena pada dinding clearance yaitu tip clearance flow di mana ketika aliran udara melewati dinding akan mengalami up stream yang mengakibatkan arah aliran menuju ke atas, sedangkan pada dinding airfoil ditemukan aliran sekunder berupa curl flow yang akhirnya membentuk spiral point pada trailing edge. Perubahan sudut serang menjadi -20° membuat perbedaan tekanan antara lower side dan upper side semakin lemah, begitu juga tip clearance flow yang terjadi pada wall clearance mengalami perubahan arah menjadi down stream yang mengakibatkan arah aliran menjuu kebawah. Perubahan sudut juga berpengaruh terhadap pressure coeficient pada boundary layer airfoil dan mengakibatkan blockage effect serta terjadinya vortex yang berbeda.

  10. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method

    Science.gov (United States)

    Jiang, Zhinong; Wang, Zijia; Zhang, Jinjie

    2017-01-01

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable. PMID:29244722

  11. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method.

    Science.gov (United States)

    Jiang, Zhinong; Mao, Zhiwei; Wang, Zijia; Zhang, Jinjie

    2017-12-15

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable.

  12. IFNL4 affects clearance of hepatitis C virus

    Science.gov (United States)

    Scientists have discovered a new human interferon gene, Interferon Lambda 4 (IFNL4), that affects clearance of the hepatitis C virus. They also identified an inherited genetic variant within IFNL4 that predicts how people respond to treatment for hepatit

  13. F4/80+ Macrophages Contribute to Clearance of Senescent Cells in the Mouse Postpartum Uterus.

    Science.gov (United States)

    Egashira, Mahiro; Hirota, Yasushi; Shimizu-Hirota, Ryoko; Saito-Fujita, Tomoko; Haraguchi, Hirofumi; Matsumoto, Leona; Matsuo, Mitsunori; Hiraoka, Takehiro; Tanaka, Tomoki; Akaeda, Shun; Takehisa, Chiaki; Saito-Kanatani, Mayuko; Maeda, Kei-Ichiro; Fujii, Tomoyuki; Osuga, Yutaka

    2017-07-01

    Cellular senescence, defined as an irreversible cell cycle arrest, exacerbates the tissue microenvironment. Our previous study demonstrated that mouse uterine senescent cells were physiologically increased according to gestational days and that their abnormal accumulation was linked to the onset of preterm delivery. We hypothesized that there is a mechanism for removal of senescent cells after parturition to maintain uterine function. In the current study, we noted abundant uterine senescent cells and their gradual disappearance in wild-type postpartum mice. F4/80+ macrophages were present specifically around the area rich in senescent cells. Depletion of macrophages in the postpartum mice using anti-F4/80 antibody enlarged the area of senescent cells in the uterus. We also found excessive uterine senescent cells and decreased second pregnancy success rate in a preterm birth model using uterine p53-deleted mice. Furthermore, a decrease in F4/80+ cells and an increase in CD11b+ cells with a senescence-associated inflammatory microenvironment were observed in the p53-deleted uterus, suggesting that uterine p53 deficiency affects distribution of the macrophage subpopulation, interferes with senescence clearance, and promotes senescence-induced inflammation. These findings indicate that the macrophage is a key player in the clearance of uterine senescent cells to maintain postpartum uterine function. Copyright © 2017 Endocrine Society.

  14. Numerical Analysis of the Influence of Clearance on Stress State and Contact Pressure in Plain Bearings

    Directory of Open Access Journals (Sweden)

    Vasile Cojocaru

    2017-12-01

    Full Text Available In the analysis of plain bearings by finite element method it is important to model as closely to real state the aspects that influence the stress and contact pressure: the loading mode, the properties of the materials, the lubrication system, the clearance between the shaft and the bearing body, the evolution in time of clearance correlated with the wear, etc. In order to study the effect of the clearance on the stress state, a plain bearing with nominal diameter d=40 mm was modeled. The contact pressure and the equivalent stress were computed for six discrete values of clearance, range from c=0 to c=0.3 mm. It has been shown that the increase of clearance generates an increase of the equivalent stress and contact pressure. The growth rate is higher for contact pressure, due to the decrease of the contact surface between the shaft and the bearing body

  15. SU-F-P-28: A Method of Maximize the Noncoplanar Beam Orientations and Assure the Beam Delivery Clearance for Stereotactic Body Radiation Therapy (SBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, J [Presence St. Joseph Medical Ctr., Joliet, IL (United States)

    2016-06-15

    Purpose: Develop a method to maximize the noncoplanar beam orientations and assure the beam delivery clearance for SBRT, therefore, optimize the dose conformality to the target, increase the dose sparing to the critical normal organs and reduce the hot spots in the body. Methods: A SBRT body frame (Elekta, Stockholm, Sweden) was used for patient immobilization and target localization. The SBRT body frame has CT fiducials on its side frames. After patient’s CT scan, the radiation treatment isocenter was defined and its coordinators referring to the body frame was calculated in the radiation treatment planning process. Meanwhile, initial beam orientations were designed based on the patient target and critical organ anatomy. The body frame was put on the linear accelerator couch and positioned to the calculated isocenter. Initially designed beam orientations were manually measured by tuning the body frame position on the couch, the gantry and couch angles. The finalized beam orientations were put into the treatment planning for dosimetric calculations. Results: Without patient presence, an optimal set of beam orientations were designed and validated. The radiation treatment plan was optimized and guaranteed for delivery clearance. Conclusion: The developed method is beneficial and effective in SBRT treatment planning for individual patient. It first allows maximizing the achievable noncoplanar beam orientation space, therefore, optimize the treatment plan for specific patient. It eliminates the risk that a plan needs to be modified due to the gantry and couch collision during patient setup.

  16. pH modulation and salivary sugar clearance of different chocolates in children: A randomized clinical trial

    Directory of Open Access Journals (Sweden)

    SVSG Nirmala

    2016-01-01

    Full Text Available Background: Sugars that occur naturally in foods and those added in processed foods may act as the source for fermentable carbohydrates and may initiate caries process. Among all the foods consumed by children, chocolates form an important constituent. A wide variety of chocolates are available in the Indian market and very few studies have compared their acidogenicity and salivary sugar clearance. Objectives: To compare the acidogenicity and salivary sugar clearance of 6 different commercially available chocolates in the Indian market. Materials and Methods: Thirty subjects aged 10-15 years were selected randomly from one of the available public schools in Nellore city. Six commercially available chocolates in the Indian market were divided into three groups, unfilled (dark and milk chocolate, filled (wafer and fruit and nuts chocolate, and candy (hard milk and mango-flavored candy groups. Plaque pH values and salivary sugar clearance rates are assessed at baseline, 5, 10, 15, 20, and 30 min after consumption. All the data obtained were statistically evaluated using independent sample t-test and one-way ANOVA for multiple group comparisons. Results: Mango-flavored candy had maximum fall in plaque pH and least fall in plaque pH was recorded with milk chocolate. Fruit and nuts chocolate had a maximum clearance of salivary sugar and least fall in the salivary sugar clearance was recorded with dark chocolate. When the plaque pH and salivary sugar clearance of all the chocolates were assessed, it was seen that the values were statistically significant at all the time intervals (P < 0.05. Conclusion: Dark chocolate had a high fall in pH and milk chocolate had low salivary sugar clearance which signifies that unfilled chocolates are more cariogenic than other chocolates. Even though mango-flavored candy had maximum fall in plaque pH, its salivary sugar clearance was high.

  17. pH modulation and salivary sugar clearance of different chocolates in children: A randomized clinical trial.

    Science.gov (United States)

    Nirmala, Svsg; Quadar, Mohammed Akhil; Veluru, Sindhuri

    2016-01-01

    Sugars that occur naturally in foods and those added in processed foods may act as the source for fermentable carbohydrates and may initiate caries process. Among all the foods consumed by children, chocolates form an important constituent. A wide variety of chocolates are available in the Indian market and very few studies have compared their acidogenicity and salivary sugar clearance. To compare the acidogenicity and salivary sugar clearance of 6 different commercially available chocolates in the Indian market. Thirty subjects aged 10-15 years were selected randomly from one of the available public schools in Nellore city. Six commercially available chocolates in the Indian market were divided into three groups, unfilled (dark and milk chocolate), filled (wafer and fruit and nuts chocolate), and candy (hard milk and mango-flavored candy) groups. Plaque pH values and salivary sugar clearance rates are assessed at baseline, 5, 10, 15, 20, and 30 min after consumption. All the data obtained were statistically evaluated using independent sample t-test and one-way ANOVA for multiple group comparisons. Mango-flavored candy had maximum fall in plaque pH and least fall in plaque pH was recorded with milk chocolate. Fruit and nuts chocolate had a maximum clearance of salivary sugar and least fall in the salivary sugar clearance was recorded with dark chocolate. When the plaque pH and salivary sugar clearance of all the chocolates were assessed, it was seen that the values were statistically significant at all the time intervals (P pH and milk chocolate had low salivary sugar clearance which signifies that unfilled chocolates are more cariogenic than other chocolates. Even though mango-flavored candy had maximum fall in plaque pH, its salivary sugar clearance was high.

  18. Tear clearance and ocular symptoms in patients treated with preservative-free prostaglandins.

    Science.gov (United States)

    Giménez-Gómez, R; García-Catalán, M R; Gallardo-Galera, J M

    2013-03-01

    To assess the effects on dry eye symptoms and tear dynamics of switching from a prostaglandin with a preservative to a preservative-free prostaglandin. Fourteen patients (N=28 eyes) with open-angle glaucoma and dry eye symptons, treated with preserved latanoprost, travoprost or bimatoprost were included in this uncontrolled prospective study. Ocular symptoms were analysed using a validated ocular surface disease questionnaire and ocular signs were assessed with tear clearance, Schirmer and tear function index test (TFI=Schirmer/clearance). Patients were assigned to preservative-free tafluprost treatment, and measurements were repeated 4 weeks after change of medication. Wilcoxon test and Spearman correlation coefficient were used in the statistical analysis. No statistically significant difference in intraocular pressure (IOP) was observed after switching to tafluprost. Mean IOP at baseline was 20.4 mmHg (SD2.2) and after 4 weeks 19.9 mmHg (SD2.6), (P>.05). The mean questionnaire score significantly decreased from 9.7 (SD3.7) at baseline to 5.4 (SD2.7) after one month (P.05). At baseline, tear clearance=0.13 (SD0.07), Schirmer=10.7 mm (SD6) and TFI=80 (48-156). After 4 weeks, tear clearance=0.1(SD0.07), Schirmer=9.5 mm (3.9) and TFI=104 (48-216). A significant association between questionnaire score and tear clearance after 4 weeks was observed (Spearman coefficient=0.62; P=.014). Switching from preservative prostaglandin with a preservative to preservative-free tafluprost treatment improves dry eye symptoms and suggests an improvement in TFI. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  19. Hepatectomy Based on Future Liver Remnant Plasma Clearance Rate of Indocyanine Green

    Directory of Open Access Journals (Sweden)

    Yuichiro Uchida

    2016-01-01

    Full Text Available Background. Hepatectomy, an important treatment modality for liver malignancies, has high perioperative morbidity and mortality rates. Safe, comprehensive criteria for selecting patients for hepatectomy are needed. Since June 2011, we have used a cut-off value of ≧ 0.05 for future liver remnant plasma clearance rate of indocyanine green as a criterion for hepatectomy. The aim of this study was to verify the validity of this criterion. Methods. From June 2011 to December 2015, 212 hepatectomies were performed in Tenri Yorozu Hospital. Of these 212 patients, 107 who underwent preoperative computed tomography imaging volumetry, indocyanine green clearance test, and hepatectomy (excluding partial resection or enucleation were retrospectively analyzed. Results. There was no postoperative mortality. Posthepatectomy liver failure occurred in 59 patients (55.1% (International Study Group of Liver Surgery Grade A: 43 cases (40.2%, Grade B: 16 cases (15.0%, and Grade C: no cases. Operative morbidity greater than Clavien-Dindo Grade 3 occurred in 23 patients (21.5%. A low future liver remnant plasma clearance rate of indocyanine green was a good predictor for Grade B cases (area under curve = 0.804; 95% confidence interval, 0.712–0.895. Conclusion. Liver remnant plasma clearance rate of indocyanine green is a valid criterion for hepatectomy.

  20. Evaluation of plasma clearance by synthesis of continuous infusion: principles and use

    International Nuclear Information System (INIS)

    Chonacky, N.J.; Thomas, F.D.

    1986-01-01

    There is a technique of engineering analysis which can be described as impulse synthesis which uses the observational data of a system's response to a single sharp blow in order to predict its response to a steady force. This same technique has been applied to the calculation of in situ drug levels and for calculating plasma clearance values. The purpose of this paper is to elucidate the principles of this calculation technique and to critically assess its application to plasma clearance studies. We begin by tracing the history of the measurement of renal clearance of plasma. We then proceed to exposit the relevant principles of the synthesis technique. Finally, we report the results of our application of this technique to the analysis of simulated data in a manner intended to be of use to clinicians who might wish to consider employing the technique

  1. Effect of α-naphthylisothiocyanate on blood clearance of 99mTc-phytate in dogs

    International Nuclear Information System (INIS)

    Shibata, Hiroshi; Kohno, Masahiro; Katoh, Hirotake

    1989-01-01

    The effect of α-naphthylisothiocyanate (ANIT) on blood clearance of 99m Tc-phytate ( 99m Tc-P) in dogs was examined, and blood clearance test of 99m Tc-P was compared with the cases of serum transaminase test or serum bilirubin test. Serum transaminase and bilirubin levels in dogs increased after ANIT administration, however, the degree of increase in these parameters was much lower than the cases in rats. The disappearance rate of 99m Tc-P from blood in dogs decreased with the increase in dose of ANIT and with the passage of time after the ANIT administration. Changes of the blood clearance of 99m Tc-P after ANIT treatment in dogs may be influenced by the disorder in the hepatocytes rather than in the bile ductule cells. The blood clearance test of 99m Tc-P in dogs showed a sensitive reaction for the acute hepatic dysfunction induced by ANIT equally to the serum transaminase test or the serum bilirubin test. (author)

  2. 76 FR 45645 - 10-Day Notice of Proposed Information Collection: Technology Security/Clearance Plans, Screening...

    Science.gov (United States)

    2011-07-29

    ...: Technology Security/Clearance Plans, Screening Records, and Non-Disclosure Agreements ACTION: Notice of... Information Collection: Technology Security/ Clearance Plans, Screening Records, and Non-Disclosure Agreements...: None. Respondents: Business and Nonprofit Organizations, Foreign Governments. Estimated Number of...

  3. Hepatic clearance of 6 polyaromatic aromatic hydrocarbons by isolated trout livers: Prediction from in vitro clearance by liver S9 fractions

    Science.gov (United States)

    An isolated perfused trout liver preparation was used to evaluate in vitro-to-in vivo metabolism extrapolation procedures for fish. Hepatic clearance (CLH) studies were conducted with six polyaromatic hydrocarbons (PAH) using an experimental design wherein each liver acted as it...

  4. Protein clearance from the air spaces and lungs of unanesthetized sheep over 144 h

    International Nuclear Information System (INIS)

    Berthiaume, Y.; Albertine, K.H.; Grady, M.; Fick, G.; Matthay, M.A.

    1989-01-01

    We studied the rate, the routes, and the mechanisms for protein clearance from the air spaces and lungs of 20 unanesthetized sheep over 144 h. We instilled 100 ml of autologous serum labeled with 125I-albumin into one lung. At the end of 24, 48, 96, or 144 h, the lungs were removed and the residual native protein and 125I-albumin in the air spaces were determined by bronchoalveolar lavage. Also the fraction of the instilled 125I-albumin remaining in the rest of the lung was measured in the lung homogenate. Clearance of the 125I-albumin from the lung into the plasma, lymph, thyroid, urine, and feces was also determined. The removal of both the 125I-albumin and the native protein from the air spaces was slow, following a monoexponential decline. The removal rate of the 125I-albumin from the air spaces was slightly but significantly faster (1.6%/h) than the clearance rate of the native protein (0.9%/h). Clearance of the 125I-albumin from the lung also followed a slow monoexponential decline at a rate of 1.4%/h. At all time periods, 75% of the 125I-albumin remaining in the lung was located in the air spaces, thus indicating that the pulmonary epithelium is the principal barrier to protein clearance from the normal lung. Macrophages appeared to play a minor role in alveolar protein clearance because the quantity of 125I-albumin present in the phagocytic cells in the air spaces was less than 1% of the instilled 125I-albumin at all time periods. However, macrophages may play some role in protein clearance after 48 h because we visualized phagolysosomes in macrophages, and there was an increase in free iodine in lung lavage, urine, thyroid, and feces after 48 h. However, gel electrophoretic studies showed that most of the 125I-albumin was cleared from the lung as an intact molecule, although only 24.7 +/- 4.7% of the 125I-albumin was cleared by the lymphatics

  5. Mucociliary clearance following tracheal resection and end-to-end anastomosis.

    Science.gov (United States)

    Toomes, H; Linder, A

    1989-10-01

    Mucociliary clearance is an important cleaning system of the bronchial tree. The complex transport system reacts sensitively to medicinal stimuli and inhaled substances. A disturbance causes secretion retention which encourages the development of acute and chronic pulmonary diseases. It is not yet known in which way sectional resection of the central airway effects mucociliary clearance. A large number of the surgical failures are attributable to septic complications in the area of the anastomosis. In order to study the transportation process over the anastomosis, ten dogs underwent a tracheal resection with end-to-end anastomosis, and the mucociliary activity was recorded using a bronchoscopic video-technical method. Recommencement of mucous transport was observed on the third, and transport over the anastomosis from the sixth to tenth, postoperative days. The mucociliary clearance had completely recovered on the twenty-first day in the majority of dogs. Histological examination of the anastomoses nine months postoperatively showed a flat substitute epithelium without cilia-bearing cells in all dogs. This contrasts with the quick restitution of the transport function. In case of undamaged respiratory mucosa, a good adaptation of the resection margins suffices for the mucous film to slide over the anastomosis.

  6. Evaluation of aorto-iliac disease with Doppler ultrasound and isotope clearance techniques

    Energy Technology Data Exchange (ETDEWEB)

    Appleberg, M [University of the Witwatersrand, Johannesburg (South Africa). Dept. of Surgery; Lewis, J D

    1975-10-04

    The clearance of /sup 99/mTc from the hamstring muscle compartment of patients with aorto-iliac or iliac disease was examined with the patients at rest and after exercise. The values were compared with those obtained in a group of controls and another group with superficial femoral, or femoropopliteal arterial occlusion. A statistically significant difference in the rate of /sup 99/mTc clearance was found in patients with proximal vascular disease.

  7. Creatinine Clearance and Estimated Glomerular Filtration Rate – When are they Interchangeable

    OpenAIRE

    Šimetić, Lucija; Zibar, Lada; Drmić, Sandra; Begić, Ivana; Šerić, Vatroslav

    2015-01-01

    Study goal was to examine which of glomerular rate equations is most suitable for prediction of creatinine clearance. Using a retrospective review of data from 500 hospital patients we calculated glomerular filtration rate according to Cockcroft-Gault equation (C-G), Modification of Diet in Renal Disease Study equation (MDRD) and Chronic Kidney Disease Epidemiology Collaboration equation (CKD-EPI). We determined if results of these equations were compatible with creatinine clearance, and does...

  8. Cathelicidin host defence peptide augments clearance of pulmonary Pseudomonas aeruginosa infection by its influence on neutrophil function in vivo.

    Directory of Open Access Journals (Sweden)

    Paula E Beaumont

    Full Text Available Cathelicidins are multifunctional cationic host-defence peptides (CHDP; also known as antimicrobial peptides and an important component of innate host defence against infection. In addition to microbicidal potential, these peptides have properties with the capacity to modulate inflammation and immunity. However, the extent to which such properties play a significant role during infection in vivo has remained unclear. A murine model of acute P. aeruginosa lung infection was utilised, demonstrating cathelicidin-mediated enhancement of bacterial clearance in vivo. The delivery of exogenous synthetic human cathelicidin LL-37 was found to enhance a protective pro-inflammatory response to infection, effectively promoting bacterial clearance from the lung in the absence of direct microbicidal activity, with an enhanced early neutrophil response that required both infection and peptide exposure and was independent of native cathelicidin production. Furthermore, although cathelicidin-deficient mice had an intact early cellular inflammatory response, later phase neutrophil response to infection was absent in these animals, with significantly impaired clearance of P. aeruginosa. These findings demonstrate the importance of the modulatory properties of cathelicidins in pulmonary infection in vivo and highlight a key role for cathelicidins in the induction of protective pulmonary neutrophil responses, specific to the infectious milieu. In additional to their physiological roles, CHDP have been proposed as future antimicrobial therapeutics. Elucidating and utilising the modulatory properties of cathelicidins has the potential to inform the development of synthetic peptide analogues and novel therapeutic approaches based on enhancing innate host defence against infection with or without direct microbicidal targeting of pathogens.

  9. Bone blood flow measured by 41Ar clearance formed by 44Ca(n,α)41Ar

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; DeLuca, P.M. Jr.; Pearson, D.W.; Nickles, R.J.

    1983-01-01

    A technique to measure regional inert gas washout in bone, in vivo, by measuring 41 Ar clearance formed by fast-neutron activation of 44 Ca has been developed. Following fast-neutron irradiation of whole rats, the perfusion-limited clearance of 41 Ar was measured for both dead and living rats. The clearance rate for the live rats indicate that the bone perfusion is in the range of 3 to 20 ml/100 Argon distribution volume

  10. Effects of shoe sole geometry on toe clearance and walking stability in older adults.

    Science.gov (United States)

    Thies, S B; Price, C; Kenney, L P J; Baker, R

    2015-07-01

    Thirty-five percent of people above age 65 fall each year, and half of their falls are associated with tripping: tripping, an apparently 'mundane' everyday problem, therefore, significantly impacts on older people's health and associated medical costs. To avoid tripping and subsequent falling, sufficient toe clearance during the swing phase is crucial. We previously found that a rocker-shaped shoe sole enhances toe clearance in young adults, thereby decreasing their trip-risk. This study investigates whether such sole design also enhances older adults' toe clearance, without inadvertently affecting their walking stability. Toe clearance and its variability are reported together with measures of walking stability for twelve older adults, walking in shoes with rocker angles of 10°, 15°, and 20°. Surface inclinations (flat, incline, decline) were chosen to reflect a potential real-world environment. Toe clearance increased substantially from the 10° to the 15° rocker angle (p=0.003) without compromising measures of walking stability (p>0.05). A further increase in rocker angle to 20° resulted in less substantial enhancement of toe clearance and came at the cost of a decrease in gait speed on the decline. The novelty of this investigation lies in the exploration of the trade-off between reduction of trip-risk through footwear design and adverse effects on walking stability on real-life relevant surfaces. Our two studies suggest that the current focus on slip-resistance in footwear design may need to be generalised to include other factors that affect trip-risk. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Turbo machine tip clearance and vibration measurements using a fibre optic laser Doppler position sensor

    Science.gov (United States)

    Pfister, T.; Büttner, L.; Czarske, J.; Krain, H.; Schodl, R.

    2006-07-01

    This paper presents a novel fibre optic laser Doppler position sensor for single blade tip clearance and vibration measurements at turbo machines, which offers high temporal resolution and high position resolution simultaneously. The sensor principle is based on the generation of a measurement volume consisting of two superposed fan-like interference fringe systems with contrary fringe spacing gradients using wavelength division multiplexing. A flexible and robust measurement system with an all-passive fibre coupled measurement head has been realized employing diffractive and refractive optics. Measurements of tip clearance and rotor vibrations at a transonic centrifugal compressor performed during operation at up to 50 000 rpm (833 Hz) corresponding to 21.7 kHz blade frequency and 586 m s-1 blade tip velocity are presented. The results are in excellent agreement with those of capacitive probes. The mean uncertainty of the position measurement was around 20 µm and, thus, considerably better than for conventional tip clearance probes. Consequently, this sensor is capable of fulfilling the requirements for future active clearance control systems and has great potential for in situ and online tip clearance and vibration measurements at metallic and non-metallic turbine blades with high precision.

  12. Airway epithelial NF-κB activation promotes Mycoplasma pneumoniae clearance in mice.

    Directory of Open Access Journals (Sweden)

    Di Jiang

    Full Text Available Respiratory infections including atypical bacteria Mycoplasma pneumoniae (Mp contribute to the pathobiology of asthma and chronic obstructive pulmonary disease (COPD. Mp infection mainly targets airway epithelium and activates various signaling pathways such as nuclear factor κB (NF-κB. We have shown that short palate, lung, and nasal epithelium clone 1 (SPLUNC1 serves as a novel host defense protein and is up-regulated upon Mp infection through NF-κB activation in cultured human and mouse primary airway epithelial cells. However, the in vivo role of airway epithelial NF-κB activation in host defense against Mp infection has not been investigated. In the current study, we investigated the effects of in vivo airway epithelial NF-κB activation on lung Mp clearance and its association with airway epithelial SPLUNC1 expression.Non-antimicrobial tetracycline analog 9-t-butyl doxycycline (9-TB was initially optimized in mouse primary tracheal epithelial cell culture, and then utilized to induce in vivo airway epithelial specific NF-κB activation in conditional NF-κB transgenic mice (CC10-(CAIKKβ with or without Mp infection. Lung Mp load and inflammation were evaluated, and airway epithelial SPLUNC1 protein was examined by immunohistochemistry. We found that 9-TB treatment in NF-κB transgene positive (Tg+, but not transgene negative (Tg- mice significantly reduced lung Mp load. Moreover, 9-TB increased airway epithelial SPLUNC1 protein expression in NF-κB Tg+ mice.By using the non-antimicrobial 9-TB, our study demonstrates that in vivo airway epithelial NF-κB activation promotes lung bacterial clearance, which is accompanied by increased epithelial SPLUNC1 expression.

  13. Serum and glucocorticoid-regulated kinase 1 regulates neutrophil clearance during inflammation resolution.

    Science.gov (United States)

    Burgon, Joseph; Robertson, Anne L; Sadiku, Pranvera; Wang, Xingang; Hooper-Greenhill, Edward; Prince, Lynne R; Walker, Paul; Hoggett, Emily E; Ward, Jonathan R; Farrow, Stuart N; Zuercher, William J; Jeffrey, Philip; Savage, Caroline O; Ingham, Philip W; Hurlstone, Adam F; Whyte, Moira K B; Renshaw, Stephen A

    2014-02-15

    The inflammatory response is integral to maintaining health by functioning to resist microbial infection and repair tissue damage. Large numbers of neutrophils are recruited to inflammatory sites to neutralize invading bacteria through phagocytosis and the release of proteases and reactive oxygen species into the extracellular environment. Removal of the original inflammatory stimulus must be accompanied by resolution of the inflammatory response, including neutrophil clearance, to prevent inadvertent tissue damage. Neutrophil apoptosis and its temporary inhibition by survival signals provides a target for anti-inflammatory therapeutics, making it essential to better understand this process. GM-CSF, a neutrophil survival factor, causes a significant increase in mRNA levels for the known anti-apoptotic protein serum and glucocorticoid-regulated kinase 1 (SGK1). We have characterized the expression patterns and regulation of SGK family members in human neutrophils and shown that inhibition of SGK activity completely abrogates the antiapoptotic effect of GM-CSF. Using a transgenic zebrafish model, we have disrupted sgk1 gene function and shown this specifically delays inflammation resolution, without altering neutrophil recruitment to inflammatory sites in vivo. These data suggest SGK1 plays a key role in regulating neutrophil survival signaling and thus may prove a valuable therapeutic target for the treatment of inflammatory disease.

  14. Determination of Minimum Air Clearances for a 420kV Novel Unibody Composite Cross-Arm

    DEFF Research Database (Denmark)

    Jahangiri, Tohid; Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2015-01-01

    One of the most important requirements of any overhead line tower is determining the air clearances between live parts and earthed parts such as phase conductor and tower structure. In contrast to traditional steel lattice towers, the recently introduced fully composite pylon is completely made....... This paper presents the insulation coordination studies to determine minimum required air clearances on the unibody cross-arm. The procedure and relevant equations to calculate minimum air clearances to avoid flashover between phases’ conductors as well as top phase conductor and shield wire are based...

  15. The UK Nuclear Industry Code of Practice on Clearances and Exemptions

    International Nuclear Information System (INIS)

    Owen, D.

    2004-01-01

    In 2001, the major nuclear organisations in the United Kingdom started development of a document that would identify and facilitate consistent the application of good practice within the industry for clearing and sentencing of articles, substances and wastes which may be clean, or radioactive at very low levels below thresholds of regulatory control. The document includes: (i) Clarification of the industry's interpretation of legislation associated with the clearance and sentencing of articles, substances and wastes which are or have the potential to have been contaminated by radioactivity or activated by nuclear radiations; (ii) Industry agreement on what is considered to be the good practice where legislation is imprecise or unclear, (iii) A standard management framework, adopted by all organisations within the nuclear industry, that should justify safe and efficient clearance of potentially radioactive articles, substances and wastes; and (IV) Agreed guidance on the principles, processes and practices which should be followed for clearances and sentencing The Document mandates a system that allows articles and substances to be released from further control, where this is appropriate, using robust radiological protection principles. The need to avoid sentencing of clean materials as radioactive waste where this is not appropriate, the primacy of bulk, rather than surface radioactivity clearance criteria, and the need to disallow such clearances until all relevant legislation has been satisfied, are all clear principles contained within the document. An interim issue of the Code of Practice was issued in May 2003. This version has been formally adopted by all of the major users of radioactive material in the United Kingdom, and has two main objectives: -Trial use of the concepts at the working level, and - As a basis for further discussion with interested stakeholders. The paper summarises: - How the interim version of the Code of Practice was developed; - The

  16. Proficiency testing criteria for clearance level in solid waste gamma measurement in Taiwan

    International Nuclear Information System (INIS)

    Chen, Chun-Liang; Wang, Jeng-Jong; Chiu, Huang-Sheng

    2013-01-01

    To guarantee the measurement quality for clearance level in solid waste material, the Institute of Nuclear Energy Research (INER) established the criteria for proficiency testing of clearance level measurement. INER and the Taiwan Accreditation Foundation (TAF) organized the Technique Committee Meeting twice to discuss these criteria in 2011. The participating laboratories must completely conform to the ISO/IEC 17025, and they also must meet the requirements of the criteria. According to the criteria, the participating laboratories analyzed the minimum detectable amount (MDA) and that should be less than 20% of the clearance level (AMDA) given in the Atomic Energy Council's (AEC) “Regulations on Clearance Level for Radioactive Waste Management”. The testing results should conform to the deviation and traceability requirements. - Highlights: • The participating laboratories must completely conform to the ISO/IEC 17025 • The proficiency testing items were basically in two categories, box and barrel types • Analyzed the MDA and that should be less than 20% of the release level given in the AEC. • The are three limitations: MDA< AMDA, -0.25< Bi<+0.5, and En≤1.0 and uncertainty<20%

  17. Ligand-based targeted therapy: a novel strategy for hepatocellular carcinoma

    Science.gov (United States)

    Li, Min; Zhang, Weiyue; Wang, Birong; Gao, Yang; Song, Zifang; Zheng, Qi Chang

    2016-01-01

    Hepatocellular carcinoma (HCC) is the most common primary liver cancer with high morbidity and mortality worldwide. Chemotherapy is recommended to patients with intermediate or advanced stage cancer. However, the conventional chemotherapy yields low desired response rates due to multidrug resistance, fast clearance rate, nonspecific delivery, severe side effects, low drug concentration in cancer cells, and so on. Nanoparticle-mediated targeted drug delivery system can surmount the aforementioned obstacles through enhanced permeability and retention effect and active targeting as a novel approach of therapeutics for HCC in recent years. The active targeting is triggered by ligands on the delivery system, which recognize with and internalize into hepatoma cells with high specificity and efficiency. This review focuses on the latest targeted delivery systems for HCC and summarizes the ligands that can enhance the capacity of active targeting, to provide some insight into future research in nanomedicine for HCC. PMID:27920520

  18. Clearance of materials resulting from the use of radionuclides in medicine, industry and research

    International Nuclear Information System (INIS)

    1998-02-01

    It has long been recognized that the use of sources of radiation should be regulated. The recommended regulatory approach is based on a system of notification and authorization exemplified by the IAEA International Basic Safety Standards for Protection Against Ionizing Radiation and for the Safety of Radiation Sources (BSS). However, some types of radiation source do not meet to be subject to regulatory control because they can only give rise to trivial radiation hazards. Such sources may be exempted or cleared from the requirements of regulatory control. Exemption applies to radiation sources which do not enter the regulatory control regime, while clearance is relevant to radiation sources which were within the regulatory regime but can be released because they present an insignificant risk to health. It is the latter situation which is the subject of this publication. While the emphasis of the report is on providing guidance on the clearance process and on methods for determining clearance leaves, taking account of site specific factors as appropriate, a set of conservatively derived generic clearance levels is also presented. These are expected to be of considerable help to users of small quantities of radionuclides in laboratories and hospitals and their regulators. They can be used, taking due account of the associated notes of caution, as reference levels for determining when clearance is the appropriate option for disposing of the materials

  19. Delayed plasma clearance and hepatic uptake of lymph chylomicron 14C-cholesterol in marginally zinc-deficient rats

    International Nuclear Information System (INIS)

    Koo, S.I.; Algilani, K.; Norvell, J.E.; Henderson, D.A.

    1986-01-01

    Previously, chylomicrons from marginally zinc-deficient rats were shown to be abnormally large, with markedly reduced levels of apoproteins C and E. In the present study, effects of such changes on the plasma clearance and hepatic uptake of chylomicron cholesterol were investigated in rats fed 3 ppm of zinc (ZD), as compared with those fed 30 ppm of zinc (CT). The rate of plasma clearance was determined by plasma 14C-radioactivity at different intervals after intravenous injection of lymph chylomicrons labeled in vivo with 14C-cholesterol. The 14C-clearance curves were nonlinear, consisting of an initial rapid phase followed by a slow phase of clearance. The initial 14C-clearance was significantly (p less than 0.05) delayed whether the labeled chylomicrons from ZD donors were injected into ZD or CT recipients. The hepatic 14C-recovery in extracted lipids was also significantly lower in ZD rats. The present data provide first evidence that a marginal level of zinc deficiency produces a significant delay in the plasma clearance and hepatic uptake of chylomicron cholesterol. This may be attributable in part to the molecular alterations of chylomicrons induced by zinc deficiency

  20. Effect of tip clearance on wall shear stress of an axial LVAD

    Science.gov (United States)

    Sarath, S.; Vikas, R.

    2017-09-01

    Wall shear stress is a crucial parameter used for blood damage analysis, and typically a value of 400 Pa is set as a limit. Tip clearance is a major factor contributing to hemolysis and pump efficiency. In this study, different tip gap configurations are used to analyse the wall shear stress developed on the blade surface of a constant thickness blade design, and a varying thickness blade design using CFD analysis. It was found that, for a particular geometry, as the clearance gap reduces, flow rate over the high wall shear stress area decreases even though the high wall shear stress span is found to extend. For each design, the optimum clearance gap is iteratively attained, keeping the maximum WSS as a limiting factor. Thus a better pump designs is obtained, whose leakage flow patterns are lower than that of the initial design, hence also leading to higher pump efficiency.

  1. The metabolic clearance rate of corticosterone in lean and obese male Zucker rats

    International Nuclear Information System (INIS)

    White, B.D.; Corll, C.B.; Porter, J.R.

    1989-01-01

    The obese Zucker rat is an animal model of human juvenile-onset obesity. These rats exhibit numerous endocrine and metabolic abnormalities. Adrenalectomy of obese rats has been shown to reduce or reverse several of these abnormalities, thereby implying that corticosterone may contribute to the expression of obesity in this animal. Furthermore, it has been shown that the circadian rhythm of plasma corticosterone is disturbed in obese Zucker rats resulting in elevated morning plasma corticosterone concentrations in obese rats as compared to lean rats. In a effort to better elucidate the mechanism of the elevated morning levels of plasma corticosterone, the metabolic clearance rate of corticosterone was determined in the morning for lean and obese male Zucker rats (12 to 20 weeks). Additionally, the biliary and urinary excretion of labeled corticosterone and/or its metabolites were determined. The metabolic clearance rate of corticosterone was significantly greater in obese rats than in their lean counterparts. Both the metabolic clearance rate and the volume of compartments significantly correlated with body weight. No correlation was found between body weight and the elimination rate constant. The increased metabolic clearance rate of obese rats appeared to be due to an increase in the physiologic distribution of corticosterone and not to an alteration in the enzymes responsible for corticosterone metabolism. It appears that the metabolic clearance rate of corticosterone in obese Zucker rats does not contribute to elevated morning concentrations of plasma corticosterone previously observed in these animals. It suggests that the adrenal corticosterone secretion rate must actually be greater than one would expect from the plasma corticosterone concentrations alone

  2. Bacterial Clearance and Cytokine Profiles in a Murine Model of Postsurgical Nosocomial Pneumonia

    OpenAIRE

    Manderscheid, Patricia A.; Bodkin, Ryan P.; Davidson, Bruce A.; Jensen, Erik; Russo, Thomas A.; Knight, Paul R.

    2004-01-01

    The development of a nosocomial pneumonia is facilitated by alterations in host innate pulmonary antibacterial defenses following surgical trauma, which can result in decreased pulmonary bacterial clearance and increased morbidity and mortality. In a murine model of postoperative nosocomial infection, surgical stress (laparotomy) decreased Escherichia coli clearance from the lungs of animals that underwent surgery. Consistent with previous studies, (i) pulmonary levels of tumor necrosis facto...

  3. International guidance on clearance criteria for application to materials containing radionuclides

    International Nuclear Information System (INIS)

    Linsley, G.

    1999-01-01

    The International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources establish the conditions whereby radiation sources can be released from control. The essential principle behind this concept, termed clearance, is that the risks associated with the released source should be trivially small. The concept has been widely applied and practically applicable clearance levels have been derived for use in regulating the recycling and reuse of materials originating from the nuclear industry. Since materials released from controls may be traded between countries in the same way as any other material, it is necessary to have international agreements on acceptable levels of radioactivity in materials so as to provide a basis for regulating such movements. The International Atomic Energy Agency, in concert with other international bodies, has for many years been engaged in promoting discussions between its Member States in this subject area. International guidance has been produced and discussions are continuing towards reaching a full consensus on internationally accepted clearance levels. (author)

  4. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children

    Energy Technology Data Exchange (ETDEWEB)

    Schofer, O. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Koenig, G. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Bartels, U. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Bockisch, A. [Department of Nuclear Medicine, Johannes-Gutenberg University, Mainz (Germany); Piepenburg, R. [Department of Nuclear Medicine, Johannes-Gutenberg University, Mainz (Germany); Beetz, R. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Meyer, G. [Department of Nuclear Medicine, Ludwig Maximilians University, Munich (Germany); Hahn, K. [Department of Nuclear Medicine, Ludwig Maximilians University, Munich (Germany)

    1995-11-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm{sup 2} body surface) in addition to normal oral fluid intake, weight-related dose of {sup 99m}Tc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as ``normal`` with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (> grade I) no single kidney and no difference in split renal function > 20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months. (orig.)

  5. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children

    International Nuclear Information System (INIS)

    Schofer, O.; Koenig, G.; Bartels, U.; Bockisch, A.; Piepenburg, R.; Beetz, R.; Meyer, G.; Hahn, K.

    1995-01-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm 2 body surface) in addition to normal oral fluid intake, weight-related dose of 99m Tc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as ''normal'' with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (> grade I) no single kidney and no difference in split renal function > 20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months. (orig.)

  6. 78 FR 22020 - Agency Information Collection Activities: Requests for Comments; Clearance of New Approval of...

    Science.gov (United States)

    2013-04-12

    ... Control Number: 2120-XXXX. Title: Safety Awareness, Feedback, and Evaluation (SAFE) Program. Form Numbers: No FAA forms are associated with this collection. Type of Review: Clearance of a new information... Activities: Requests for Comments; Clearance of New Approval of Information Collection: Safety Awareness...

  7. 76 FR 49838 - Proposed Collection; Comment Request for Generic Clearance for the Collection of Qualitative...

    Science.gov (United States)

    2011-08-11

    ... Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Internal... of Qualitative Feedback on Agency Service Delivery. DATES: Written comments should be received on or... . SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  8. 50 CFR 14.52 - Clearance of imported wildlife.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 1 2010-10-01 2010-10-01 false Clearance of imported wildlife. 14.52 Section 14.52 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND...

  9. Metabolism of oxycodone in human hepatocytes from different age groups and prediction of hepatic plasma clearance

    Directory of Open Access Journals (Sweden)

    Timo eKorjamo

    2012-01-01

    Full Text Available Oxycodone is commonly used to treat severe pain in adults and children. It is extensively metabolized in the liver in adults, but the maturation of metabolism is not well understood. Our aim was to study the metabolism of oxycodone in cryopreserved human hepatocytes from different age groups (3 days, 2 and 5 months, 4 years, adult pool and predict hepatic plasma clearance of oxycodone using these data. Oxycodone (0.1, 1 and 10 µM was incubated with hepatocytes for 4 hours, and 1 µM oxycodone also with CYP3A inhibitor ketoconazole (1 µM. Oxycodone and noroxycodone concentrations were determined at several time points with liquid chromatography-mass spectrometry. In vitro clearance of oxycodone was used to predict hepatic plasma clearance, using the well-stirred model and published physiological parameters. Noroxycodone was the major metabolite in all batches and ketoconazole inhibited the metabolism markedly in most cases. A clear correlation between in vitro oxycodone clearance and CYP3A4 activity was observed. The predicted hepatic plasma clearances were typically much lower than the published median total plasma clearance from pharmacokinetic studies. In general, this in vitro to in vivo extrapolation method provides valuable information on the maturation of oxycodone metabolism that can be utilized in the design of clinical pharmacokinetic studies in infants and young children.

  10. Gait Training with Real-Time Augmented Toe-Ground Clearance Information Decreases Tripping Risk in Older Adults and a Person with Chronic Stroke

    Directory of Open Access Journals (Sweden)

    Rezaul K Begg

    2014-05-01

    Full Text Available Falls risk increases with ageing but is substantially higher in people with stroke. Tripping-related balance loss is the primary cause of falls, and Minimum Toe Clearance (MTC during walking is closely linked to tripping risk. The aim of this study was to determine whether real-time augmented information of toe-ground clearance at MTC can increase toe clearance, and reduce tripping risk. Nine healthy older adults (76±9 years and one 71 year old female stroke patient participated. Vertical toe displacement was displayed in real-time such that participants could adjust their toe clearance during treadmill walking. Participants undertook a session of unconstrained walking (no-feedback baseline and, in a subsequent Feedback condition, were asked to modify their swing phase trajectory to match a target increased MTC. Tripping probability (PT pre- and post-training was calculated by modelling MTC distributions. Older adults showed significantly higher mean MTC for the post-training retention session (27.7 ±3.79mm compared to the normal walking trial (14.1± 8.3 mm. The PT on a 1cm obstacle for the older adults reduced from 1 in 578 strides to 1 in 105,988 strides. With gait training the stroke patient increased MTC and reduced variability (baseline 16±12 mm, post-training 24±8 mm which reduced obstacle contact probability from 1 in 3 strides in baseline to 1 in 161 strides post-training. The findings confirm that concurrent visual feedback of a lower limb kinematic gait parameter is effective in changing foot trajectory control and reducing tripping probability in older adults. There is potential for further investigation of augmented feedback training across a range of gait-impaired populations, such as stroke.

  11. [Manual airway clearance techniques in adults and adolescents: What level of evidence?

    Science.gov (United States)

    Cabillic, Michel; Gouilly, Pascal; Reychler, Gregory

    2016-04-13

    The aim of this systematic literature review was to grade the levels of evidence of the most widely used manual airway clearance techniques. A literature search was conducted over the period 1995-2014 from the Medline, PEDro, ScienceDirect, Cochrane Library, REEDOC and kinedoc databases, with the following keywords: "postural drainage", "manual vibrations", "manual chest percussion", "directed cough", "increased expiratory flow", "ELTGOL", "autogenic drainage" and "active cycle of breathing technique". Two-hundred and fifty-six articles were identified. After removing duplicates and reading the titles and abstracts, 63 articles were selected, including 9 systematic reviews. This work highlights the lack of useful scientific data and the difficulty of determining levels of evidence for manual airway clearance techniques. Techniques were assessed principally with patients with sputum production (cystic fibrosis, DDB, COPD, etc.). It also shows the limited pertinence of outcome measures to quantify congestion and hence the efficacy of airway clearance techniques. The 1994 consensus conference summary table classifying airway clearance techniques according to physical mechanism provides an interesting tool for assessment, grouping together techniques having identical mechanisms of action. From the findings of the present systematic review, it appears that only ELTGOL, autogenic drainage and ACBT present levels of evidence "B". All other techniques have lower levels of evidence. II. Copyright © 2016. Published by Elsevier Masson SAS.

  12. The detailed measurement of foot clearance by young adults during stair descent.

    Science.gov (United States)

    Telonio, A; Blanchet, S; Maganaris, C N; Baltzopoulos, V; McFadyen, B J

    2013-04-26

    Foot clearance is an important variable for understanding safe stair negotiation, but few studies have provided detailed measures of it. This paper presents a new method to calculate minimal shoe clearance during stair descent and compares it to previous literature. Seventeen healthy young subjects descended a five step staircase with step treads of 300 mm and step heights of 188 mm. Kinematic data were collected with an Optotrak system (model 3020) and three non-colinear infrared markers on the feet. Ninety points were digitized on the foot sole prior to data collection using a 6 marker probe and related to the triad of markers on the foot. The foot sole was reconstructed using the Matlab (version 7.0) "meshgrid" function and minimal distance to each step edge was calculated for the heel, toe and foot sole. Results showed significant differences in minimum clearance between sole, heel and toe, with the shoe sole being the closest and the toe the furthest. While the hind foot sole was closest for 69% of the time, the actual minimum clearance point on the sole did vary across subjects and staircase steps. This new method, and the findings on healthy young subjects, can be applied to future studies of other populations and staircase dimensions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. The Paravascular Pathway for Brain Waste Clearance: Current Understanding, Significance and Controversy

    Directory of Open Access Journals (Sweden)

    Andrew Bacyinski

    2017-11-01

    Full Text Available The paravascular pathway, also known as the “glymphatic” pathway, is a recently described system for waste clearance in the brain. According to this model, cerebrospinal fluid (CSF enters the paravascular spaces surrounding penetrating arteries of the brain, mixes with interstitial fluid (ISF and solutes in the parenchyma, and exits along paravascular spaces of draining veins. Studies have shown that metabolic waste products and solutes, including proteins involved in the pathogenesis of neurodegenerative diseases such as amyloid-beta, may be cleared by this pathway. Consequently, a growing body of research has begun to explore the association between glymphatic dysfunction and various disease states. However, significant controversy exists in the literature regarding both the direction of waste clearance as well as the anatomical space in which the waste-fluid mixture is contained. Some studies have found no evidence of interstitial solute clearance along the paravascular space of veins. Rather, they demonstrate a perivascular pathway in which waste is cleared from the brain along an anatomically distinct perivascular space in a direction opposite to that of paravascular flow. Although possible explanations have been offered, none have been able to fully reconcile the discrepancies in the literature, and many questions remain. Given the therapeutic potential that a comprehensive understanding of brain waste clearance pathways might offer, further research and clarification is highly warranted.

  14. The Paravascular Pathway for Brain Waste Clearance: Current Understanding, Significance and Controversy.

    Science.gov (United States)

    Bacyinski, Andrew; Xu, Maosheng; Wang, Wei; Hu, Jiani

    2017-01-01

    The paravascular pathway, also known as the "glymphatic" pathway, is a recently described system for waste clearance in the brain. According to this model, cerebrospinal fluid (CSF) enters the paravascular spaces surrounding penetrating arteries of the brain, mixes with interstitial fluid (ISF) and solutes in the parenchyma, and exits along paravascular spaces of draining veins. Studies have shown that metabolic waste products and solutes, including proteins involved in the pathogenesis of neurodegenerative diseases such as amyloid-beta, may be cleared by this pathway. Consequently, a growing body of research has begun to explore the association between glymphatic dysfunction and various disease states. However, significant controversy exists in the literature regarding both the direction of waste clearance as well as the anatomical space in which the waste-fluid mixture is contained. Some studies have found no evidence of interstitial solute clearance along the paravascular space of veins. Rather, they demonstrate a perivascular pathway in which waste is cleared from the brain along an anatomically distinct perivascular space in a direction opposite to that of paravascular flow. Although possible explanations have been offered, none have been able to fully reconcile the discrepancies in the literature, and many questions remain. Given the therapeutic potential that a comprehensive understanding of brain waste clearance pathways might offer, further research and clarification is highly warranted.

  15. Blanking Clearance and Punch Velocity Effects on The Sheared Edge Characteristic in Micro-Blanking of Commercially Pure Copper Sheet

    OpenAIRE

    Didin Zakaria Lubis; Ichsan Ristiawan

    2017-01-01

    This study aims to identify the influences between clearance and punch velocity on the part edge quality of blanked parts. Experiments have been conducted using material copper, punch-die clearance and punch velocity variations. In order to determine the reachable punch-die clearance and punch velocity required for blanking. The quality of the part-edge characteristics shows that higher punch velocity and decreases clearance value can improve the part-edge quality, resulting in smaller burr h...

  16. [Conservative calibration of a clearance monitor system for waste material from nuclear medicine].

    Science.gov (United States)

    Wanke, Carsten; Geworski, Lilli

    2014-09-01

    Clearance monitor systems are used for gross gamma measurements of waste potentially contaminated with radioactivity. These measurements are to make sure that legal requirements, e.g. clearance criteria according to the german radiation protection ordinance, are met. This means that measurement results may overestimate, but must not underestimate the true values. This paper describes a pragmatic way using a calibrated Cs-137 point source to generate a conservative calibration for the clearance monitor system used in the Medizinische Hochschule Hannover (MHH). The most important nuclides used in nuclear medicine are considered. The measurement result reliably overestimates the true value of the activity present in the waste. The calibration is compliant with the demands for conservativity and traceability to national standards. Copyright © 2014. Published by Elsevier GmbH.

  17. Inference of type-specific HPV transmissibility, progression and clearance rates: a mathematical modelling approach.

    Directory of Open Access Journals (Sweden)

    Helen C Johnson

    Full Text Available Quantifying rates governing the clearance of Human Papillomavirus (HPV and its progression to clinical disease, together with viral transmissibility and the duration of naturally-acquired immunity, is essential in estimating the impact of vaccination programmes and screening or testing regimes. However, the complex natural history of HPV makes this difficult. We infer the viral transmissibility, rate of waning natural immunity and rates of progression and clearance of infection of 13 high-risk and 2 non-oncogenic HPV types, making use of a number of rich datasets from Sweden. Estimates of viral transmissibility, clearance of initial infection and waning immunity were derived in a Bayesian framework by fitting a susceptible-infectious-recovered-susceptible (SIRS transmission model to age- and type-specific HPV prevalence data from both a cross-sectional study and a randomised controlled trial (RCT of primary HPV screening. The models fitted well, but over-estimated the prevalence of four high-risk types with respect to the data. Three of these types (HPV-33, -35 and -58 are among the most closely related phylogenetically to the most prevalent HPV-16. The fourth (HPV-45 is the most closely related to HPV-18; the second most prevalent type. We suggest that this may be an indicator of cross-immunity. Rates of progression and clearance of clinical lesions were additionally estimated from longitudinal data gathered as part of the same RCT. Our estimates of progression and clearance rates are consistent with the findings of survival analysis studies and we extend the literature by estimating progression and clearance rates for non-16 and non-18 high-risk types. We anticipate that such type-specific estimates will be useful in the parameterisation of further models and in developing our understanding of HPV natural history.

  18. Estimation of technetium 99m mercaptoacetyltriglycine plasma clearance by use of one single plasma sample

    International Nuclear Information System (INIS)

    Mueller-Suur, R.; Magnusson, G.; Karolinska Inst., Stockholm; Bois-Svensson, I.; Jansson, B.

    1991-01-01

    Recent studies have shown that technetium 99m mercaptoacetyltriglycine (MAG-3) is a suitable replacement for iodine 131 or 123 hippurate in gamma-camera renography. Also, the determination of its clearance is of value, since it correlates well with that of hippurate and thus may be an indirect measure of renal plasma flow. In order to simplify the clearance method we developed formulas for the estimation of plasma clearance of MAG-3 based on a single plasma sample and compared them with the multiple sample method based on 7 plasma samples. The correlation to effective renal plasma flow (ERPF) (according to Tauxe's method, using iodine 123 hippurate), which ranged from 75 to 654 ml/min per 1.73 m 2 , was determined in these patients. Using the developed regression equations the error of estimate for the simplified clearance method was acceptably low (18-14 ml/min), when the single plasma sample was taken 44-64 min post-injection. Formulas for different sampling times at 44, 48, 52, 56, 60 and 64 min are given, and we recommend 60 min as optimal, with an error of estimate of 15.5 ml/min. The correlation between the MAG-3 clearances and ERPF was high (r=0.90). Since normal values for MAG-3 clearance are not yet available, transformation to estimated ERPF values by the regression equation (ERPF=1.86xC MAG-3 +4.6) could be of clinical value in order to compare it with the normal values for ERPF given in the literature. (orig.)

  19. Immunotherapy targeting α-synuclein, with relevance for future treatment of Parkinson's disease and other Lewy body disorders.

    Science.gov (United States)

    Lindström, Veronica; Ihse, Elisabet; Fagerqvist, Therese; Bergström, Joakim; Nordström, Eva; Möller, Christer; Lannfelt, Lars; Ingelsson, Martin

    2014-01-01

    Immunotherapy targeting α-synuclein has evolved as a potential therapeutic strategy for neurodegenerative diseases, such as Parkinson's disease, and initial studies on cellular and animal models have shown promising results. α-synuclein vaccination of transgenic mice reduced the number of brain inclusions, whereas passive immunization studies demonstrated that antibodies against the C-terminus of α-synuclein can pass the blood-brain barrier and affect the pathology. In addition, preliminary evidence suggests that transgenic mice treated with an antibody directed against α-synuclein oligomers/protofibrils resulted in reduced levels of such species in the CNS. The underlying mechanisms of immunotherapy are not yet fully understood, but may include antibody-mediated clearance of pre-existing aggregates, prevention of protein propagation between cells and microglia-dependent protein clearance. Thus, immunotherapy targeting α-synuclein holds promise, but needs to be further developed as a future disease-modifying treatment in Parkinson's disease and other α-synucleinopathies.

  20. Error modelling and experimental validation of a planar 3-PPR parallel manipulator with joint clearances

    DEFF Research Database (Denmark)

    Wu, Guanglei; Bai, Shaoping; Kepler, Jørgen Asbøl

    2012-01-01

    This paper deals with the error modelling and analysis of a 3-PPR planar parallel manipulator with joint clearances. The kinematics and the Cartesian workspace of the manipulator are analyzed. An error model is established with considerations of both configuration errors and joint clearances. Using...