WorldWideScience

Sample records for subjects underwent contrast-enhanced

  1. MR imaging of the early rheumatoid arthritis: usefulness of contrast enhanced fat suppressed SPGR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Mi; Joo, Kyung Bin; Kim, Seong Tae; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    1995-06-15

    To evaluate value of post-contrast 3-Dimensional fat suppressed Spoiled GRASS (FS SPGR) in detecting subtle bony erosion and tenosynovitis of hands and wrists due to early rheumatoid arthritis. Fourteen MR imagings of the hands and wrists were performed in 7 early rheumatoid arthritis without any abnormalities in plain radiography and in 7 healthy volunteers. All subjects underwent MR sequence of coronal 3D FS SPGR with and without contrast enhancement in 1.5T MR unit. We evaluated the number of the bony erosion and tenosynovitis respectively in pre-and post-contrast FS SPGR images. The abnormal enhancing areas were not demonstrated in 7 healthy volunteers. Seven patients had 25 bony erosions in pre-contrast FS SPGR and 52 bony erosions with tenosynovitis (n = 10) in post-contrast FS SPGR. Enhancing joint spaces were shown in 8 cases. Post-contrast FS SPGR was better than pre-contrast FS SPGR in the evaluation of early rheumatoid arthritis and is valuable as a baseline study.

  2. MR imaging of the early rheumatoid arthritis: usefulness of contrast enhanced fat suppressed SPGR imaging

    International Nuclear Information System (INIS)

    Kim, Sun Mi; Joo, Kyung Bin; Kim, Seong Tae; Hahm, Chang Kok

    1995-01-01

    To evaluate value of post-contrast 3-Dimensional fat suppressed Spoiled GRASS (FS SPGR) in detecting subtle bony erosion and tenosynovitis of hands and wrists due to early rheumatoid arthritis. Fourteen MR imagings of the hands and wrists were performed in 7 early rheumatoid arthritis without any abnormalities in plain radiography and in 7 healthy volunteers. All subjects underwent MR sequence of coronal 3D FS SPGR with and without contrast enhancement in 1.5T MR unit. We evaluated the number of the bony erosion and tenosynovitis respectively in pre-and post-contrast FS SPGR images. The abnormal enhancing areas were not demonstrated in 7 healthy volunteers. Seven patients had 25 bony erosions in pre-contrast FS SPGR and 52 bony erosions with tenosynovitis (n = 10) in post-contrast FS SPGR. Enhancing joint spaces were shown in 8 cases. Post-contrast FS SPGR was better than pre-contrast FS SPGR in the evaluation of early rheumatoid arthritis and is valuable as a baseline study

  3. Clinical observation of the adverse drug reactions caused by non-ionic iodinated contrast media: results from 109,255 cases who underwent enhanced CT examination in Chongqing, China.

    Science.gov (United States)

    Li, X; Chen, J; Zhang, L; Liu, H; Wang, S; Chen, X; Fang, J; Wang, S; Zhang, W

    2015-03-01

    To analyse the pattern and factors that influence the incidence of adverse drug reactions (ADRs) induced by non-ionic iodinated contrast media and to evaluate their safety profiles. Data from 109,255 cases who underwent enhanced CT examination from 1 January 2008 to 31 August 2013 were analysed. ADRs were classified according to the criteria issued by the American College of Radiology and the Chinese Society of Radiology. A total of 375 (0.34%) patients had ADRs, including 281 mild (0.26%); 80 moderate (0.07%); and 14 severe (0.01%) ADRs; no death was found. 302 (80.53%) of the ADRs occurred within 15 min after examination. Patients aged 40-49 years (204 cases, 0.43%; p contrast media are mainly mild ones, while moderate or severe ADRs are relatively rare, suggesting that enhanced CT examination with non-ionic iodinated contrast media is highly safe, and severe adverse events will seldom occur under appropriate care. The study included 109,255 patients enrolled in various types of enhanced CT examinations, which could reflect ADR conditions and regulations in Chinese population accurately and reliably.

  4. Comparison of Oral Contrast-Enhanced Transabdominal Ultrasound Imaging With Transverse Contrast-Enhanced Computed Tomography in Preoperative Tumor Staging of Advanced Gastric Carcinoma.

    Science.gov (United States)

    He, Xuemei; Sun, Jing; Huang, Xiaoling; Zeng, Chun; Ge, Yinggang; Zhang, Jun; Wu, Jingxian

    2017-12-01

    This study assessed the diagnostic performance of transabdominal oral contrast-enhanced ultrasound (US) imaging for preoperative tumor staging of advanced gastric carcinoma by comparing it with transverse contrast-enhanced computed tomography (CT). This retrospective study included 42 patients with advanced gastric cancer who underwent laparoscopy, radical surgery, or palliative surgery because of serious complications and had a body mass index of less than 25 kg/m 2 . A cereal-based oral contrast agent was used for transabdominal oral contrast-enhanced US. Retrospective analyses were conducted using preoperative tumor staging data acquired by either transabdominal oral contrast-enhanced US or transverse contrast-enhanced CT. Both contrast-enhanced US and contrast-enhanced CT examinations were reviewed by 2 experienced radiologists independently for preoperative tumor staging according to the seventh edition of the TNM classification. The accuracy, sensitivity, and specificity were calculated by comparing the results of contrast-enhanced US and contrast-enhanced CT with pathologic findings. The overall accuracies of the imaging modalities were compared by the McNemar test. No significant difference was noted in the overall accuracy of transabdominal oral contrast-enhanced US (86% [36 of 42]) and transverse contrast-enhanced CT (83% [35 of 42] P > .999). For stage T2 to T4 gastric cancer, the accuracies of transabdominal oral contrast-enhanced US were 88%, 86%, and 98%, respectively, and those of transverse contrast-enhanced CT were 93%, 83%, and 90%. The overall accuracy of transabdominal oral contrast-enhanced US was comparable with that of transverse contrast-enhanced CT for preoperative tumor staging of advanced gastric cancer. © 2017 by the American Institute of Ultrasound in Medicine.

  5. The relationship between contrast enhancement on CT and cerebral vasospasm in patient with subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Tazawa, Toshiaki; Mizukami, Masahiro; Kawase, Takeshi; Usami, Takashi; Togashi, Osamu

    1982-01-01

    Sixty patients with a single rupture of an aneurysm were subjected to study. Contrast enhanced CT (CECT) was performed by intravenous infusion of 100 ml of 60% meglumine iothalamate in 10 minutes. Post-contrast CT scans were repeated serially just after infusion, 15 minutes and 30 minutes later. Prominent increase in density in the region of the circle of Willis and its branches 30 minutes after infusion was considered as remarkable enhancement. In 17 (46%) out of 37 patients who underwent CECT within day 3, the contrast enhancement was remarkable. Transient or permanent symptomatic vasospasm occurred in 13 (76.5%) out of these 17 patients and the remaining 4 patients who underwent the operation with successful removal of subarachnoid clot within day 3 did not develop symptomatic vasospasm. Eight (67%) out of 12 patients operated within day 3, in whom post-operative CT showed incomplete removal of subarachnoid clot, developed transient or permanent symptomatic vasospasm. In only one (5%) out of 20 patients without remarkable enhancement, transient symptomatic vasospasm occurred. The abnormal contrast enhancement in the region of the circle of Willis and its branches within day 3 was closely related to the subsequent occurrence of vasospasm. Contrast enhanced CT was performed in 41 patients after day 3. There was no patient with remarkable enhancement on CECT. There was no relationship between the findings on CECT after day 3 and the occurrence of vasospasm. CECT within day 3 allows prediction of that patient destined for vasospasm and early removal of subarachnoid clot within day 3 may minimize the future development of vasospasm.(J.P.N.)

  6. Correlation of contrast agent kinetics between iodinated contrast-enhanced spectral tomosynthesis and gadolinium-enhanced MRI of breast lesions

    International Nuclear Information System (INIS)

    Froeling, Vera; Diekmann, Felix; Renz, Diane M.; Fallenberg, Eva M.; Steffen, Ingo G.; Diekmann, Susanne; Schmitzberger, Florian F.; Lawaczeck, Ruediger

    2013-01-01

    Assessment of contrast agent kinetics in contrast-enhanced MRI (CE-MRI) with gadolinium-containing contrast agents offers the opportunity to predict breast lesion malignancy. The goal of our study was to determine if similar patterns exist for spectral contrast-enhanced digital breast tomosynthesis (CE-DBT) using an iodinated contrast agent. The protocol of our prospective study was approved by the relevant institutional review board and the German Federal Office for Radiation Protection. All patients provided written informed consent. We included 21 women with a mean age of 62.4 years. All underwent ultrasound-guided biopsy of a suspect breast lesion, spectral CE-DBT and CE-MRI. For every breast lesion, contrast agent kinetics was assessed by signal intensity-time curves for spectral CE-DBT and CE-MRI. Statistical comparison used Cohen's kappa and Spearman's rho test. Spearman's rho of 0.49 showed significant (P = 0.036) correlation regarding the contrast agent kinetics in signal intensity-time curves for spectral CE-DBT and CE-MRI. Cohen's kappa indicated moderate agreement (kappa = 0.438). There is a statistically significant correlation between contrast agent kinetics in the signal intensity-time curves for spectral CE-DBT and CE-MRI. Observing intralesional contrast agent kinetics in spectral CE-DBT may aid evaluation of malignant breast lesions. (orig.)

  7. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function.

    Science.gov (United States)

    Park, Sung Yoon; Kim, Chan Kyo; Kim, EunJu; Park, Byung Kwan

    2015-02-01

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88% of right and 92% of left renal arteries, while it was 96% in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82% and 100% for reader 1 and 82% and 95% for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. • Accurate pre-treatment evaluation of renal artery anatomy helps clinical decision-making. • NC-MRA using RAVEL offers acceptable imaging quality for renal artery evaluation. • The 3 T RAVEL technique provides excellent diagnostic performance for renal artery evaluation. • The 3 T RAVEL technique may be an alternative to contrast-enhanced MRA.

  8. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  9. Ultrasonographic contrast-enhanced study of sicca syndrome

    International Nuclear Information System (INIS)

    Giuseppetti, Gian Marco; Argalia, Giulio; Salera, Diego; Ranaldi, Roberto; Danieli, Giovanna; Cappelli, Marida

    2005-01-01

    Objective: To assess the ability of US contrast-enhanced time-intensity curves to depict the changes connected with sicca syndrome, a fairly common condition that is often associated with autoimmune disorders such as Sjogren's syndrome or other diseases. Diagnostic criteria are complex and controversial and although no single test can be considered the gold standard, salivary gland scintigraphy and biopsy are reliable diagnostic methods. Materials and methods: Sixty consecutive patients with sicca syndrome, 40 of whom had primary (n = 23) or secondary (n = 17) Sjogren's syndrome and 20 had non-Sjogren's sicca syndrome, selected according to European Community Study Group diagnostic criteria for Sjogren's syndrome and subjected to contrast-enhanced US imaging of the parotids using a second-generation contrast agent with analysis of time-intensity curves at rest and during salivary stimulation, Tc99m salivary gland scintigraphy and labial gland biopsy. Results: In the 40 Sjogren's patients, US enhancement values were significantly lower (P < 0.0001 and P < 0.00003, respectively) than in the 20 non-Sjogren's patients both at rest and during stimulation. In the 23 subjects with the primary syndrome, values during stimulation were significantly lower than in the 17 subjects with the secondary syndrome (P < 0.0006), whereas at rest differences were not significant. Contrast-enhanced US imaging allowed to discriminate Sjogren's from non-Sjogren's sicca patients with 87.5% sensitivity, 85% specificity and 86.7% accuracy and the primary from the secondary syndrome with 78.2% sensitivity, 70.5% specificity and 75% accuracy. Interestingly, in eight patients with the primary syndrome, i.e. those with the more severe gland involvement, enhancement values were lower during stimulation than at rest. Conclusion: Preliminary results indicate that contrast-enhanced US imaging can provide useful information on sicca characterisation and severity

  10. Ultrasonographic contrast-enhanced study of sicca syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Giuseppetti, Gian Marco [Institute of Radiology, University School of Medicine, Umberto I Hospital, Via Conca 1, Ancona (Italy)]. E-mail: gm.giuseppetti@ao-umbertoprimo.marche.it; Argalia, Giulio [Institute of Radiology, University School of Medicine, Umberto I Hospital, Via Conca 1, Ancona (Italy); Salera, Diego [Institute of Radiology, University School of Medicine, Umberto I Hospital, Via Conca 1, Ancona (Italy); Ranaldi, Roberto [Institute of Pathological Anatomy and Histopathology, University School of Medicine, Umberto I Hospital, Ancona (Italy); Danieli, Giovanna [Institute of Internal Medicine, University School of Medicine, Umberto I Hospital, Ancona (Italy); Cappelli, Marida [Institute of Internal Medicine, University School of Medicine, Umberto I Hospital, Ancona (Italy)

    2005-05-01

    Objective: To assess the ability of US contrast-enhanced time-intensity curves to depict the changes connected with sicca syndrome, a fairly common condition that is often associated with autoimmune disorders such as Sjogren's syndrome or other diseases. Diagnostic criteria are complex and controversial and although no single test can be considered the gold standard, salivary gland scintigraphy and biopsy are reliable diagnostic methods. Materials and methods: Sixty consecutive patients with sicca syndrome, 40 of whom had primary (n = 23) or secondary (n = 17) Sjogren's syndrome and 20 had non-Sjogren's sicca syndrome, selected according to European Community Study Group diagnostic criteria for Sjogren's syndrome and subjected to contrast-enhanced US imaging of the parotids using a second-generation contrast agent with analysis of time-intensity curves at rest and during salivary stimulation, Tc99m salivary gland scintigraphy and labial gland biopsy. Results: In the 40 Sjogren's patients, US enhancement values were significantly lower (P < 0.0001 and P < 0.00003, respectively) than in the 20 non-Sjogren's patients both at rest and during stimulation. In the 23 subjects with the primary syndrome, values during stimulation were significantly lower than in the 17 subjects with the secondary syndrome (P < 0.0006), whereas at rest differences were not significant. Contrast-enhanced US imaging allowed to discriminate Sjogren's from non-Sjogren's sicca patients with 87.5% sensitivity, 85% specificity and 86.7% accuracy and the primary from the secondary syndrome with 78.2% sensitivity, 70.5% specificity and 75% accuracy. Interestingly, in eight patients with the primary syndrome, i.e. those with the more severe gland involvement, enhancement values were lower during stimulation than at rest. Conclusion: Preliminary results indicate that contrast-enhanced US imaging can provide useful information on sicca characterisation and

  11. Contrast-enhanced magnetic resonance venography in pediatric patients with chronic kidney disease: initial experience with ferumoxytol

    International Nuclear Information System (INIS)

    Luhar, Aarti; Khan, Sarah; Ghahremani, Shahnaz; Griggs, Rachel; Hall, Theodore R.; Finn, J.P.; Zaritsky, Joshua; Salusky, Isidro

    2016-01-01

    Ferumoxytol is an ultra-small superparamagnetic iron oxide (USPIO) particle that is FDA-approved for parenteral treatment of iron deficiency anemia in adults with chronic kidney disease. Because of the association between gadolinium-based contrast agents and nephrogenic systemic fibrosis in patients with severe chronic kidney disease, we sought to evaluate the diagnostic role of ferumoxytol-enhanced MR venography in children with chronic kidney disease. Twenty children underwent 22 high-resolution ferumoxytol-enhanced MR venography examinations at 3.0 T. High-resolution 3-D contrast-enhanced imaging was performed at a minimum of 3 time points following injection of ferumoxytol at a total dose of 4 mg/kg. Two blinded pediatric radiologists independently scored six named veins on ferumoxytol-enhanced MR venography examinations according to a three-point subjective score, where a score ≥2 was considered diagnostic. Additionally, all relevant venous structures in the included field of view were analyzed for occlusive or non-occlusive thrombosis, compression and presence of collaterals. All patients underwent ferumoxytol-enhanced MR venography successfully and without adverse event. The overall scores of the reviewing radiologists for all venous structures were 2.7-2.9. In all cases, the reviewers were confident basing their diagnoses on the ferumoxytol-enhanced MR venography findings. In 12 of 22 examinations, findings on follow-up imaging or invasive procedures were available to correlate with the findings on ferumoxytol-enhanced MR venography. There was complete concordance between the findings from follow-up imaging and invasive procedures with findings from ferumoxytol-enhanced MR venography. Ferumoxytol holds promise as a powerful alternative to gadolinium-based contrast agents for reliable, high-resolution MR venography in children with chronic kidney disease. (orig.)

  12. Sequential contrast-enhanced MR imaging of the penis.

    Science.gov (United States)

    Kaneko, K; De Mouy, E H; Lee, B E

    1994-04-01

    To determine the enhancement patterns of the penis at magnetic resonance (MR) imaging. Sequential contrast material-enhanced MR images of the penis in a flaccid state were obtained in 16 volunteers (12 with normal penile function and four with erectile dysfunction). Subjects with normal erectile function showed gradual and centrifugal enhancement of the corpora cavernosa, while those with erectile dysfunction showed poor enhancement with abnormal progression. Sequential contrast-enhanced MR imaging provides additional morphologic information for the evaluation of erectile dysfunction.

  13. Polycystic ovary syndrome: dynamic contrast-enhanced ovary MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, C. Zuhal E-mail: sunarerdem@yahoo.com; Bayar, Ulku; Erdem, L. Oktay; Barut, Aykut; Gundogdu, Sadi; Kaya, Erdal

    2004-07-01

    Objective: to determine the enhancement behaviour of the ovaries in women with polycystic ovary syndrome (PCOS) by dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging and to compare these data with those of normal ovulating controls. Method: 24 women with PCOS and 12 controls underwent DCE-MR imaging. Dynamic images were acquired before and after injection of a contrast bolus at 30 s and the min of 1, 2, 3, 4 and 5. On postprocessing examination: (i) the ovarian volumes; (ii) the signal intensity value of each ovary per dynamic study; (iii) early-phase enhancement rate; (iv) time to peak enhancement (T{sub p}); and (v) percentage of washout of 5th min were determined. Data of the ovaries of the women with PCOS and controls were compared with Mann-Whitney U-test. Results: the mean values of T{sub p} were found to be significantly lower in women with PCOS than in controls (p<0.05). On the other hand, the mean values of ovarian volume, the early-phase enhancement rate, and percentage of washout of 5th min of ovaries were significantly higher in PCOS patients (p<0.05). Examination of the mean signal intensity-time curve revealed the ovaries in women with PCOS showed a faster and greater enhancement and wash-out. Conclusion: the enhancement behaviour of ovaries of women with PCOS may be significantly different from those of control subjects on DCE-MR imaging examination. In our experience, it is a valuable modality to highlight the vascularization changes in ovarian stroma with PCOS. We believe that improved DCE-MR imaging techniques may also provide us additional parameters in the diagnosis and treatment strategies of PCOS.

  14. Polycystic ovary syndrome: dynamic contrast-enhanced ovary MR imaging

    International Nuclear Information System (INIS)

    Erdem, C. Zuhal; Bayar, Ulku; Erdem, L. Oktay; Barut, Aykut; Gundogdu, Sadi; Kaya, Erdal

    2004-01-01

    Objective: to determine the enhancement behaviour of the ovaries in women with polycystic ovary syndrome (PCOS) by dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging and to compare these data with those of normal ovulating controls. Method: 24 women with PCOS and 12 controls underwent DCE-MR imaging. Dynamic images were acquired before and after injection of a contrast bolus at 30 s and the min of 1, 2, 3, 4 and 5. On postprocessing examination: (i) the ovarian volumes; (ii) the signal intensity value of each ovary per dynamic study; (iii) early-phase enhancement rate; (iv) time to peak enhancement (T p ); and (v) percentage of washout of 5th min were determined. Data of the ovaries of the women with PCOS and controls were compared with Mann-Whitney U-test. Results: the mean values of T p were found to be significantly lower in women with PCOS than in controls (p<0.05). On the other hand, the mean values of ovarian volume, the early-phase enhancement rate, and percentage of washout of 5th min of ovaries were significantly higher in PCOS patients (p<0.05). Examination of the mean signal intensity-time curve revealed the ovaries in women with PCOS showed a faster and greater enhancement and wash-out. Conclusion: the enhancement behaviour of ovaries of women with PCOS may be significantly different from those of control subjects on DCE-MR imaging examination. In our experience, it is a valuable modality to highlight the vascularization changes in ovarian stroma with PCOS. We believe that improved DCE-MR imaging techniques may also provide us additional parameters in the diagnosis and treatment strategies of PCOS

  15. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Yoon [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Severance Hospital, Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Seoul (Korea, Republic of); Kim, Chan Kyo; Park, Byung Kwan [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Kim, EunJu [Philips Healthcare Korea, Seoul (Korea, Republic of)

    2014-09-13

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88 % of right and 92 % of left renal arteries, while it was 96 % in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82 % and 100 % for reader 1 and 82 % and 95 % for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. (orig.)

  16. Performance of integrated FDG-PET/contrast-enhanced CT in the staging and restaging of colorectal cancer: Comparison with PET and enhanced CT

    International Nuclear Information System (INIS)

    Dirisamer, Albert; Halpern, Benjamin S.; Floery, Daniel; Wolf, Florian; Beheshti, Mohsen; Mayerhoefer, Marius E.; Langsteger, Werner

    2010-01-01

    Objective: The purpose of this study was to assess the diagnostic value of PET/CT as a one step examination in patients with colorectal cancer. Therefore we proved whether diagnostic PET/CT adds information over PET or contrast-enhanced CT alone for staging or restaging of patients with colorectal cancer. Methods: Seventy-three patients (46 males and 27 females; age range: 50-81 years; mean age: 67 years) with known colorectal cancer underwent 18F-FDG-PET/CT for staging or restaging. Results: Of the 73 patients 26 patients underwent PET/CT for staging and 47 for restaging. 266 metastases could be detected in 60 patients. Contrast-enhanced PET/CT had a lesion-based sensitivity of 100%, contrast-enhanced CT of 91% and PET of 85%. PET/CT identified 2 lesions as false positive. PET/CT could also reach a patient-based sensitivity of 100%, which was superior to contrast-enhanced CT and PET. Conclusion: Our study clearly demonstrated the added value of contrast-enhanced PET/CT in staging and restaging patients with colorectal cancer over CT and PET alone.

  17. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    International Nuclear Information System (INIS)

    Moselewski, Fabian; Ferencik, Maros; Achenbach, Stephan; Abbara, Suhny; Cury, Ricardo C.; Booth, Sarah L.; Jang, Ik-Kyung; Brady, Thomas J.; Hoffmann, Udo

    2006-01-01

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT

  18. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moselewski, Fabian [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Ferencik, Maros [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Achenbach, Stephan [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Internal Medicine II (Cardiology), University of Erlangen (Germany); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Booth, Sarah L. [Jean Mayer USDA Human Nutrition Research Center on Aging, 711 Washington St., Boston, MA 02114 (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)]. E-mail: uhoffman@partners.org

    2006-03-15

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM] at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 {+-} 68.7 HU versus 295 {+-} 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

  19. Contrast enhanced MRI findings of ductal carcinoma in situ

    International Nuclear Information System (INIS)

    Kang, Bong Joo; Cha, Eun Suk; Kim, Hyeon Sook; Suh, Young Jin; Choi, Hyun Joo

    2006-01-01

    The purpose of this study is to describe characteristic contrast enhanced MR mammographic findings of ductal carcinoma in situ (DCIS) and also DCIS with microinvasion. From January 2000 to July 2005, 32 women with 33 lesions affected by DCIS or DCIS with microinvasion underwent contrast enhanced MRI, and they were then retrospectively evaluated. All the patients had previously undergone mammography and ultrasonography. All the findings of mammography, ultrasonography (US), and MRI were analyzed by using an ACR BI-RADS lexicon. All 33 cases were enhanced on the enhanced MR images. A smooth margined homogeneous enhanced mass was seen in the two (2/33) cases, and nonmass enhancement was seen in 31 (31/33) cases. Among the non-mass enhancement, focal enhancement (7/31), ductal enhancement (5/31), segmental enhancement (9/31), and regional enhancement (10/31) were observed. On the kinetic study, a wash-out pattern (10/33), a plateau pattern (20/33), and a persistent pattern (3/33) were demonstrated. No significant differences were noted between the pure and microinvasive DCIS. There is no significant difference between pure and microinvasive DCIS. However, contrast enhanced MR images can demonstrate occult foci, multifocal lesion and the tumor extent of DCIS on mammogram or ultrasonogram

  20. 3D non-contrast-enhanced ECG-gated MR angiography of the lower extremities with dual-source radiofrequency transmission at 3.0 T: Intraindividual comparison with contrast-enhanced MR angiography in PAOD patients.

    Science.gov (United States)

    Rasper, Michael; Wildgruber, Moritz; Settles, Marcus; Eckstein, Hans-Henning; Zimmermann, Alexander; Reeps, Christian; Rummeny, Ernst J; Huber, Armin M

    2016-09-01

    To compare prospectively image quality and diagnostic confidence of flow-sensitive 3D turbo spin echo (TSE)-based non-contrast-enhanced MR angiography (NE-MRA) at 3.0 T using dual-source radiofrequency (RF) transmission with contrast-enhanced MRA (CE-MRA) in patients with peripheral arterial occlusive disease (PAOD). After consent was obtained, 35 patients (mean age 69.1 ± 10.6 years) with PAOD stage II-IV underwent NE-MRA followed by CE-MRA. Signal-to-noise ratio and contrast-to-noise ratio were calculated. Subjective image quality was independently assessed by two radiologists and stenosis scoring was performed in 875 arterial segments. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for stenosis classification were calculated using CE-MRA as a reference method. Diagnostic agreement with CE-MRA was evaluated with Cohen's kappa statistics. NE-MRA provided high objective and subjective image quality at all levels of the arterial tree. Sensitivity and specificity for the detection of relevant stenosis was 91 % and 89 %, respectively; the NPV was 96 % and the PPV 78 %. There was good concordance between CE-MRA and NE-MRA in stenosis scoring. 3D electrocardiography (ECG)-gated TSE NE-MRA with patient-adaptive dual-source RF transmission at 3.0 T is a promising alternative for PAOD patients with contraindications for gadolinium-based contrast agents. It offers high sensitivity and NPV values in the detection of clinically relevant arterial stenosis. • Flow-sensitive TSE NE-MRA is a promising technique for PAOD evaluation. • Diagnostic accuracy is comparable to contrast-enhanced MRA. • NE-MRA eliminates the risk of NSF in patients with renal insufficiency. • Costs arising from the use of contrast agents can be avoided.

  1. Applications of contrast enhanced CT through external jugular access

    International Nuclear Information System (INIS)

    Xu Qiaolan; Zou Wenxing; Chen Meixia; Xie Hongbo

    2005-01-01

    Objective: A retrospective analysis and evaluation for the effects of contrast enhanced computed tomography through external jugular access. Methods: 1250 cases (male 692 and female 558) underwent CT contrast enhanced examination were retrospectively reviewed from May, 2002 to Oct, 2002. The patients aged from 12 to 86 years, averagely 49 years. Contrast agent (Ultravist) was given through an intravenous catheter placed in the cubital vein. Precise injection rates were ensured by a power injector (Medrad MCT310, USA). Excellent enhancement was achieved with this protocol in most of the patients, while external jugular access was established in 96 cases because it was unable to setup a cubital venous access. Results: Good enhancement were acquired when 96 cases of contrast agent injected through external jugular vein. And the external jugular access was setup successfully with a single puncture. Conclusion: It is a common occasion when patient undergoing contrast enhanced CT scan is in poor conditions: debility, cachexia, or with complication of chemotherapy or radiation therapy, which often results in invalidity of cabital venous access, and consequently, making bolus injection impossible. The external jugular vein is a large and central blood vessel, which is easy to setup an access. In our experience, an external jugular access should be recommended as a substitution if the cubital venous access is not available. (authors)

  2. Applications of contrast enhanced CT through external jugular access

    Energy Technology Data Exchange (ETDEWEB)

    Qiaolan, Xu; Wenxing, Zou; Meixia, Chen; Hongbo, Xie [The First Affiliated Hospital of Sun Yat-sen University, Guangzhou (China). Dept. of Radiology

    2005-09-15

    Objective: A retrospective analysis and evaluation for the effects of contrast enhanced computed tomography through external jugular access. Methods: 1250 cases (male 692 and female 558) underwent CT contrast enhanced examination were retrospectively reviewed from May, 2002 to Oct, 2002. The patients aged from 12 to 86 years, averagely 49 years. Contrast agent (Ultravist) was given through an intravenous catheter placed in the cubital vein. Precise injection rates were ensured by a power injector (Medrad MCT310, USA). Excellent enhancement was achieved with this protocol in most of the patients, while external jugular access was established in 96 cases because it was unable to setup a cubital venous access. Results: Good enhancement were acquired when 96 cases of contrast agent injected through external jugular vein. And the external jugular access was setup successfully with a single puncture. Conclusion: It is a common occasion when patient undergoing contrast enhanced CT scan is in poor conditions: debility, cachexia, or with complication of chemotherapy or radiation therapy, which often results in invalidity of cabital venous access, and consequently, making bolus injection impossible. The external jugular vein is a large and central blood vessel, which is easy to setup an access. In our experience, an external jugular access should be recommended as a substitution if the cubital venous access is not available. (authors)

  3. Dynamic contrast-enhanced subtraction MR angiography in intracranial vascular abnormalities

    International Nuclear Information System (INIS)

    Takano, K.; Ono, H.; Utsunomiya, H.; Okazaki, M.; Tanaka, A.

    1999-01-01

    We present our clinical experience with dynamic contrast-enhanced MR angiography (MRA) with subtraction for assessing intracranial vascular abnormalities. Ten patients with various cerebrovascular disorders underwent dynamic contrast-enhanced MRA on a 1.0-T system. Thirty sections (2 mm) were acquired in 29-30 s. Maximum intensity projection images and subtracted source images were compared with those obtained by conventional angiography. In all cases, the presence or absence of abnormalities in the targeted vessels, as well as the morphology of the sagittal sinuses, was clearly visualized as in conventional angiography, without any obstructions such as hyperintense hematomas or thrombi, or intraluminal turbulence. Although the temporal and spatial resolutions with current hardware are insufficient, these preliminary results suggest that dynamic contrast-enhanced MRA with subtraction may be useful for assessing vascular lesions with hemorrhage or thrombus, and the dural sinuses. (orig.)

  4. Contrast-enhanced sonography for quantitative assessment of portal hypertension in patients with liver cirrhosis.

    Science.gov (United States)

    Qu, En-Ze; Zhang, Ying-Cai; Li, Zhi-Yan; Liu, Yang; Wang, Jin-Rui

    2014-11-01

    The clinical utility of contrast-enhanced sonography in portal hypertension remains unclear. We explored the feasibility of using contrast-enhanced sonography for noninvasive assessment of portal venous pressure. Twenty healthy individuals (control group; 9 men; mean age, 46.4 years) and 18 patients with portal hypertension (15 men; mean age, 46.2 years) were enrolled in this study. The portal hypertension group included patients who underwent splenectomy and pericardial blood vessel disarticulation at our hospital from October 2010 to March 2011. One week before surgery, patients with portal hypertension underwent preoperative liver contrast-enhanced sonography. Two-dimensional, Doppler, and contrast-enhanced sonographic parameters were compared between the groups. Portal venous pressure was measured intraoperatively by portal vein puncture in the portal hypertension group, and its relationship with the other parameters was analyzed. The 2-dimensional, Doppler, and contrast-enhanced sonographic parameters differed between the groups (P Portal venous pressure was inversely correlated with the area under the portal vein/hepatic artery time-intensity curve ratio (Qp/Qa), portal vein/hepatic artery strength ratio (Ip/Ia), and portal vein/hepatic artery wash-in perfusion slope ratio (βp/βa), with correlation coefficients of -0.701, -0.625, and -0.494, respectively. Measurement of the liver contrast-enhanced sonographic parameters Qp/Qa, Ip/Ia, and βp/βa could be used as a new quantitative method for noninvasively assessing portal venous pressure. © 2014 by the American Institute of Ultrasound in Medicine.

  5. Contrast-enhanced spectral mammography (CESM) and contrast enhanced MRI (CEMRI): Patient preferences and tolerance.

    Science.gov (United States)

    Hobbs, Max M; Taylor, Donna B; Buzynski, Sebastian; Peake, Rachel E

    2015-06-01

    Contrast-enhanced spectral mammography (CESM) may have similar diagnostic performance to Contrast-enhanced MRI (CEMRI) in the diagnosis and staging of breast cancer. To date, research has focused exclusively on diagnostic performance when comparing these two techniques. Patient experience is also an important factor when comparing and deciding on which of these modalities is preferable. The aim of this study is to compare patient experience of CESM against CEMRI during preoperative breast cancer staging. Forty-nine participants who underwent both CESM and CEMRI, as part of a larger trial, completed a Likert questionnaire about their preference for each modality according to the following criteria: comfort of breast compression, comfort of intravenous (IV) contrast injection, anxiety and overall preference. Participants also reported reasons for preferring one modality to the other. Quantitative data were analysed using a Wilcoxon sign-rank test and chi-squared test. Qualitative data are reported descriptively. A significantly higher overall preference towards CESM was demonstrated (n = 49, P < 0.001), with faster procedure time, greater comfort and lower noise level cited as the commonest reasons. Participants also reported significantly lower rates of anxiety during CESM compared with CEMRI (n = 36, P = 0.009). A significantly higher rate of comfort was reported during CEMRI for measures of breast compression (n = 49, P = 0.001) and the sensation of IV contrast injection (n = 49, P = 0.003). Our data suggest that overall, patients prefer the experience of CESM to CEMRI, adding support for the role of CESM as a possible alternative to CEMRI for breast cancer staging. © 2015 The Royal Australian and New Zealand College of Radiologists.

  6. Contrast-enhanced spectral mammography (CESM) and contrast enhanced MRI (CEMRI): Patient preferences and tolerance

    International Nuclear Information System (INIS)

    Hobbs, Max; Buzynski, Sebastian; Taylor, Donna B.; Peake, Rachel E.

    2015-01-01

    Contrast-enhanced spectral mammography (CESM) may have similar diagnostic performance to Contrast-enhanced MRI (CEMRI) in the diagnosis and staging of breast cancer. To date, research has focused exclusively on diagnostic performance when comparing these two techniques. Patient experience is also an important factor when comparing and deciding on which of these modalities is preferable. The aim of this study is to compare patient experience of CESM against CEMRI during preoperative breast cancer staging. Forty-nine participants who underwent both CESM and CEMRI, as part of a larger trial, completed a Likert questionnaire about their preference for each modality according to the following criteria: comfort of breast compression, comfort of intravenous (IV) contrast injection, anxiety and overall preference. Participants also reported reasons for preferring one modality to the other. Quantitative data were analysed using a Wilcoxon sign-rank test and chi-squared test. Qualitative data are reported descriptively. A significantly higher overall preference towards CESM was demonstrated (n = 49, P < 0.001), with faster procedure time, greater comfort and lower noise level cited as the commonest reasons. Participants also reported significantly lower rates of anxiety during CESM compared with CEMRI (n = 36, P = 0.009). A significantly higher rate of comfort was reported during CEMRI for measures of breast compression (n = 49, P = 0.001) and the sensation of IV contrast injection (n = 49, P = 0.003). Our data suggest that overall, patients prefer the experience of CESM to CEMRI, adding support for the role of CESM as a possible alternative to CEMRI for breast cancer staging.

  7. Therapeutic response assessment of percutaneous radiofrequency ablation for hepatocellular carcinoma: Utility of contrast-enhanced agent detection imaging

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Choi, Dongil; Lim, Hyo K.; Kim, Seung Hoon; Lee, Won Jae; Kim, Min Ju; Lee, Ji Yeon; Jeon, Yong Hwan; Lee, Jongmee; Lee, Soon Jin; Lim, Jae Hoon

    2005-01-01

    Purpose: To assess the utility of contrast-enhanced agent detection imaging (ADI) in the assessment of the therapeutic response to percutaneous radiofrequency (RF) ablation in patients with hepatocellular carcinoma (HCC). Materials and methods: Ninety patients with a total of 97 nodular HCCs (mean, 2.1 ± 1.3 cm; range, 1.0-5.0 cm) treated with percutaneous RF ablation under the ultrasound guidance were evaluated with contrast-enhanced ADI after receiving an intravenous bolus injection of a microbubble contrast agent (SH U 508A). We obtained serial contrast-enhanced ADI images during the time period from 15 to 90 s after the initiation of the bolus contrast injection. All of the patients underwent a follow-up four-phase helical CT at 1 month after RF ablation, which was then repeated at 2-4 month intervals during a period of at least 12 months. The results of the contrast-enhanced ADI were compared with those of the follow-up CT in terms of the presence or absence of residual unablated tumor and local tumor progression in the treated lesions. Results: On contrast-enhanced ADI, technical success was obtained in 94 (97%) of the 97 HCCs, while residual unablated tumors were found in three HCCs (3%). Two of the three tumors that were suspicious (was not proven) for incomplete ablation were subjected to additional RF ablation. The remaining one enhancing lesion that was suspicious of a residual tumor on contrast-enhanced ADI was revealed to be reactive hyperemia at the 1-month follow-up CT. Therefore; the diagnostic concordance between the contrast-enhanced ADI and 1-month follow-up CT was 99%. Of the 94 ablated HCCs without residual tumors on both the contrast-enhanced ADI and 1-month follow-up CT after the initial RF ablation, five (5%) had CT findings of local tumor progression at a subsequent follow-up CT. Conclusion: Despite its limitations in predicting local tumor progression in the treated tumors, contrast-enhanced ADI is potentially useful for evaluating the

  8. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  9. Characteristics of hypertrophic cardiomyopathy on delayed contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Yan Chaowu; Zhao Shihua; Li Hua; Jiang Shiliang; Lu Minjie; Zhang Yan; Wei Yunqing; Ling Jian; Fang Wei

    2010-01-01

    Objective: To analyze the characteristics of hypertrophic cardiomyopathy (HCM) on delayed contrast-enhanced cardiac magnetic resonance imaging (CMRI). Methods: All patients underwent delayed contrast-enhanced CMRI. The left ventricle was divided into 9 segments to assess the location, extent and function of the hypertrophic segments. The t test was applied for the statistics. Results: Of 154 patients, delayed enhancement of' hypertrophic segment was found in 95 cases and non-delayed enhancement in 59 cases. The thickness and number of hypertrophic segment in patients with delayed enhancement were larger than those with non-delayed enhancement [(24.8±5.5) mm vs (20.4± 3.8) mm, t=3.82, P<0.05; (3.3±1.9) vs (2.4±1.7), t=2.26, P<0.05], and the age was younger [(46.0±15.2) years vs (55.0±11.9) years, t=-3.67, P<0.05]. The diffuse enhancement was found in 62 patients, and confluent enhancement in 33 patients. Confluent enhancement was found in all 14 patients after the alcohol ablation procedure. Conclusion: The age, thickness and number of hypertrophic segments in patients with delayed enhancement are different from those with non-delayed enhancement. (authors)

  10. Dynamic contrast-enhanced MR imaging of endometrial cancer. Optimizing the imaging delay for tumour-myometrium contrast

    International Nuclear Information System (INIS)

    Park, Sung Bin; Moon, Min Hoan; Sung, Chang Kyu; Oh, Sohee; Lee, Young Ho

    2014-01-01

    To investigate the optimal imaging delay time of dynamic contrast-enhanced magnetic resonance (MR) imaging in women with endometrial cancer. This prospective single-institution study was approved by the institutional review board, and informed consent was obtained from the participants. Thirty-five women (mean age, 54 years; age range, 29-66 years) underwent dynamic contrast-enhanced MR imaging with a temporal resolution of 25-40 seconds. The signal intensity difference ratios between the myometrium and endometrial cancer were analyzed to investigate the optimal imaging delay time using single change-point analysis. The optimal imaging delay time for appropriate tumour-myometrium contrast ranged from 31.7 to 268.1 seconds. The median optimal imaging delay time was 91.3 seconds, with an interquartile range of 46.2 to 119.5 seconds. The median signal intensity difference ratios between the myometrium and endometrial cancer were 0.03, with an interquartile range of -0.01 to 0.06, on the pre-contrast MR imaging and 0.20, with an interquartile range of 0.15 to 0.25, on the post-contrast MR imaging. An imaging delay of approximately 90 seconds after initiating contrast material injection may be optimal for obtaining appropriate tumour-myometrium contrast in women with endometrial cancer. (orig.)

  11. Application of low dose radiation and low concentration contrast media in enhanced CT scans in children with congenital heart disease.

    Science.gov (United States)

    Liu, Zhimin; Song, Lei; Yu, Tong; Gao, Jun; Zhang, Qifeng; Jiang, Ling; Liu, Yong; Peng, Yun

    2016-09-01

    The aim of this study was to explore the feasibility of using low dose radiation and low concentration contrast media in enhanced CT examinations in children with congenital heart disease. Ninety patients with congenital heart disease were randomly divided into three groups of 30 patients each who underwent contrast-enhanced cardiac scans on a Discovery CT750 HD scanner. Group A received 270 mg I/mL iodixanol, and group B received 320 mg I/mL iodixanol contrast media and was scanned with prospective ECG triggering mode. Group C received 320 mg I/mL iodixanol and was scanned with conventional retrospective ECG gating mode. The same weight-based contrast injection protocol was used for all three groups. Images were reconstructed using a 30% adaptive statistical iterative reconstruction (ASIR) algorithm and a 50% ASIR in groups A and B and a 30% ASIR in group C. The subjective and objective image quality evaluations, diagnostic accuracies, radiation doses and amounts of contrast media in the three groups were measured and compared. All images in the three groups met the diagnostic requirements, with the same diagnostic accuracy and image quality scores greater than 3 in a 4-point scoring system. However, ventricular enhancement and the objective noise, signal-to-noise ratio, contrast-to-noise ratio and subjective image quality scores in group C were better than those in groups A and B (all Pcontrast dose (14% lower than that of groups B and C). Enhanced CT scan images with low dose radiation and low concentration contrast media can meet the diagnostic requirements for examining children with congenital heart disease while reducing the potential risk of radiation damage and contrast-induced nephropathy. © 2016 John Wiley & Sons Ltd.

  12. Evaluation of delayed contrast-enhanced CT scan in diagnosing hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Jianding; Liang Chenyang; Zhang Hua; Zhang Yuezhen; Li Rui

    2001-01-01

    Objective: To assess the diagnostic value of delayed CT contrast enhancement patterns in hilar cholangiocarcinoma based on two-phased dynamic incremental CT scanning. Methods: Fifty-two patients with suspected hilar tumor and bile duct obstruction underwent spiral CT scan. The scan time for one revolution of the X-ray tube was 1 second. To elucidate the delay time for optimal imaging, all proved cholangiocarcinoma with delayed (6, 8, 10, 15, 20, 30 minutes) post-equilibrium-phase contrast-enhanced CT scans were acquired with unenhanced, dynamic contrast-enhanced, and delayed images. Degree of delayed enhancement was compared with that of surrounding liver parenchyma. Results: (1) 8-15 minutes after IV injection of contrast material was the delay time for optimal imaging. (2) Of 29 cholangiocarcinomas, the early CT showed hypo-attenuating (lower than that of liver parenchyma) in 23 tumors, iso-attenuating (equal to that of the liver) in 4 tumors, and hyper-attenuating (higher than that of liver) in 2 tumors. The delayed CT scan showed iso-attenuating in 8 tumors, hyper-attenuating in 21 tumors, and no hypo-attenuating. Most of delay imaging of hilar cholangiocarcinoma may appear hyper-attenuating (U = -4.3073, P 2 = 9.09, P < 0.01). Conclusion: When assessing hilar tumor, delayed CT contrast enhancement patterns based on two-phase dynamic incremental CT scans is useful in the detection and characterization of hilar cholangiocarcinoma

  13. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    Science.gov (United States)

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. Clinical evaluation of contrast-enhanced digital mammography and contrast enhanced tomosynthesis--Comparison to contrast-enhanced breast MRI.

    Science.gov (United States)

    Chou, Chen-Pin; Lewin, John M; Chiang, Chia-Ling; Hung, Bao-Hui; Yang, Tsung-Lung; Huang, Jer-Shyung; Liao, Jia-Bin; Pan, Huay-Ben

    2015-12-01

    To compare the diagnostic accuracy of contrast-enhanced digital mammography (CEDM) and contrast-enhanced tomosynthesis (CET) to dynamic contrast enhanced breast MRI (DCE-MRI) using a multireader-multicase study. Institutional review board approval and informed consents were obtained. Total 185 patients (mean age 51.3) with BI-RADS 4 or 5 lesions were evaluated before biopsy with mammography, tomosynthesis, CEDM, CET and DCE-MRI. Mediolateral-oblique and cranio-caudal views of the target breast CEDM and CET were acquired at 2 and 4 min after contrast agent injection. A mediolateral-oblique view of the non-target breast was taken at 6 min. Each lesion was scored with forced BI-RADS categories by three readers. Each reader interpreted lesions in the following order: mammography, tomosynthesis, CEDM, CET, and DCE-MRI during a single reading session. Histology showed 81 cancers and 144 benign lesions in the study. Of the 81 malignant lesions, 44% (36/81) were invasive and 56% (45/81) were non-invasive. Areas under the ROC curve, averaged for the 3 readers, were as follows: 0.897 for DCE-MRI, 0.892 for CET, 0.878 for CEDM, 0.784 for tomosynthesis and 0.740 for mammography. Significant differences in AUC were found between the group of contrast enhanced modalities (CEDM, CET, DCE-MRI) and the unenhanced modalities (all p0.05). CET and CEDM may be considered as an alternative modality to MRI for following up women with abnormal mammography. All three contrast modalities were superior in accuracy to conventional digital mammography with or without tomosynthesis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

    International Nuclear Information System (INIS)

    Jensen, Nikolaj K. G.; Stewart, Errol; Lock, Michael; Fisher, Barbara; Kozak, Roman; Chen, Jeff; Lee, Ting-Yim; Wong, Eugene

    2014-01-01

    Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT

  16. Assessment of contrast enhanced respiration managed cone-beam CT for image guided radiotherapy of intrahepatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Nikolaj K. G., E-mail: nkyj@regionsjaelland.dk [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Stewart, Errol [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Imaging Research Lab, Robarts Research Institute, London, Ontario N6A 5B7 (Canada); Imaging Program, Lawson Health Research Institute, London, Ontario N6C 2R5 (Canada); Lock, Michael; Fisher, Barbara [Radiation Oncology, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Kozak, Roman [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Chen, Jeff [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Lee, Ting-Yim [Radiology, St. Joseph' s Health Care, London, Ontario N6A 4V2 (Canada); Imaging Research Lab, Robarts Research Institute, London, Ontario N6A 5B7 (Canada); Imaging Program, Lawson Health Research Institute, London, Ontario N6C 2R5 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Wong, Eugene [Physics and Engineering, London Regional Cancer Program, London, Ontario N6A3K7 (Canada); Department of Oncology, University of Western Ontario, London, Ontario N6A 4L6 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Department of Physics and Astronomy, University of Western Ontario, London, Ontario N6A 3K7 (Canada)

    2014-05-15

    Purpose: Contrast enhancement and respiration management are widely used during image acquisition for radiotherapy treatment planning of liver tumors along with respiration management at the treatment unit. However, neither respiration management nor intravenous contrast is commonly used during cone-beam CT (CBCT) image acquisition for alignment prior to radiotherapy. In this study, the authors investigate the potential gains of injecting an iodinated contrast agent in combination with respiration management during CBCT acquisition for liver tumor radiotherapy. Methods: Five rabbits with implanted liver tumors were subjected to CBCT with and without motion management and contrast injection. The acquired CBCT images were registered to the planning CT to determine alignment accuracy and dosimetric impact. The authors developed a simulation tool for simulating contrast-enhanced CBCT images from dynamic contrast enhanced CT imaging (DCE-CT) to determine optimal contrast injection protocols. The tool was validated against contrast-enhanced CBCT of the rabbit subjects and was used for five human patients diagnosed with hepatocellular carcinoma. Results: In the rabbit experiment, when neither motion management nor contrast was used, tumor centroid misalignment between planning image and CBCT was 9.2 mm. This was reduced to 2.8 mm when both techniques were employed. Tumors were not visualized in clinical CBCT images of human subjects. Simulated contrast-enhanced CBCT was found to improve tumor contrast in all subjects. Different patients were found to require different contrast injections to maximize tumor contrast. Conclusions: Based on the authors’ animal study, respiration managed contrast enhanced CBCT improves IGRT significantly. Contrast enhanced CBCT benefits from patient specific tracer kinetics determined from DCE-CT.

  17. Automatized spleen segmentation in non-contrast-enhanced MR volume data using subject-specific shape priors

    Science.gov (United States)

    Gloger, Oliver; Tönnies, Klaus; Bülow, Robin; Völzke, Henry

    2017-07-01

    To develop the first fully automated 3D spleen segmentation framework derived from T1-weighted magnetic resonance (MR) imaging data and to verify its performance for spleen delineation and volumetry. This approach considers the issue of low contrast between spleen and adjacent tissue in non-contrast-enhanced MR images. Native T1-weighted MR volume data was performed on a 1.5 T MR system in an epidemiological study. We analyzed random subsamples of MR examinations without pathologies to develop and verify the spleen segmentation framework. The framework is modularized to include different kinds of prior knowledge into the segmentation pipeline. Classification by support vector machines differentiates between five different shape types in computed foreground probability maps and recognizes characteristic spleen regions in axial slices of MR volume data. A spleen-shape space generated by training produces subject-specific prior shape knowledge that is then incorporated into a final 3D level set segmentation method. Individually adapted shape-driven forces as well as image-driven forces resulting from refined foreground probability maps steer the level set successfully to the segment the spleen. The framework achieves promising segmentation results with mean Dice coefficients of nearly 0.91 and low volumetric mean errors of 6.3%. The presented spleen segmentation approach can delineate spleen tissue in native MR volume data. Several kinds of prior shape knowledge including subject-specific 3D prior shape knowledge can be used to guide segmentation processes achieving promising results.

  18. Contrast-enhanced MR imaging of the endolymphatic sac in patients with sudden hearing loss

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Koshikawa, Tokiko; Fukatsu, Hiroshi; Ishigaki, Takeo; Nakashima, Tsutomu; Ichinose, Nobuyasu

    2002-01-01

    Our objective was to evaluate the frequency of contrast enhancement of the endolymphatic sac in patients with sudden hearing loss. Forty consecutive patients with sudden sensorineural hearing loss (20 males and 20 females; age range 11-82 years), 40 age-matched control subjects, and 5 patients with Meniere's disease were examined using the same imaging protocol on a 1.5-T MR system. Pre- and post-contrast-enhanced T1-weighted 3D spoiled gradient-echo sequence (3D SPGR; TR/TE=23/10 ms, no. of excitations=1, flip angle=30 ) images were obtained using a voxel size of 0.6 x 0.7 x 0.8 mm 3 . Contrast enhancement in the area of the endolymphatic sac was assessed by two radiologists, and the frequency of contrast enhancement was compared between the three study groups. Enhancement of the ipsilateral endolymphatic sac was observed in 30 of the 40 patients with sudden hearing loss (75%). Twenty of these 30 patients also showed enhancement on the contralateral side, and 1 patient showed enhancement only on the contralateral side. Only 1 of the 5 patients with Meniere's disease showed enhancement. Nine of the 40 control subjects (22.5%) showed enhancement (bilateral enhancement in 5 subjects, unilateral in 4). The frequency of enhancement in patients with sudden hearing loss was significantly higher than that in control subjects (P<0.0001) or patients with Meniere's disease (P<0.05). The frequency of contrast enhancement of the endolymphatic sac is significantly increased in patients with sudden hearing loss, but further study is necessary to clarify the relationship between this finding and the pathophysiology of sudden hearing loss. (orig.)

  19. Differentiation of focal liver lesions by contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Heintz, P.; Ehrenheim, C.

    1989-01-01

    47 patients with liver tumours (haemangioma, focal nodular hyperplasia, hepatocellular carcinoma) underwent MRI of the liver before and after i.v. injection of 0.2 ml./kg. gadolinium-DTPA in addition to other imaging methods. The demarcation of focal nodular hyperplasia is not influenced by use of the contrast agent as it almost behaves like surrounding normal liver tissue, thus only indirectly facilitating its identification. With regard to liver haemangiomas that show the most intensive uptake of gadolinium-DTPA, the contrast enhanced image does not reach to contrast and sensitivity of a native T 2 -weighted SE image, especially in cases of small haemangiomas. The contrast agent is helpful, however, in the recognition of large cavernous haemangiomas that are partially fibrotic or thrombotic. Emphasis is given to the contrast agent in hepatomas: gadolinium-DTPA presents a pattern of uptake and distribution frequently found in hepatocellular carcinoma providing additional information on the delineation of internal tumour details. (orig.) [de

  20. Post-operative monitoring of tissue transfers: advantages using contrast enhanced ultrasound (CEUS) and contrast enhanced MRI (ceMRI) with dynamic perfusion analysis?

    Science.gov (United States)

    Lamby, P; Prantl, L; Fellner, C; Geis, S; Jung, E M

    2011-01-01

    The immediate evaluation of microvascular tissue flaps with respect to microcirculation after transplantation is crucial for optimal monitoring and outcome. The purpose of our investigation was to evaluate the clinical value of contrast-enhanced ultrasound (CEUS) and contrast-enhanced MRI (ceMRI) for monitoring the integrity of tissue flaps in plastic surgery. To this end, we investigated 10 patients (47 ± 16 a) between postoperative day 7 and 14 who underwent flap surgery in order to cover tissue defects in various body regions. For CEUS we utilized the GE LOGIQ E9 equipped with a linear transducer (6-9 MHz). After application of 2.4 ml SonoVue, the tissue perfusion was detected in Low MI-Technique (MI present, both technologies provide an optimal assessment of perfusion in cutaneous, subcutaneous and muscle tissue layers, whereby the detection of fatty tissue perfusion is currently more easily detected using CEUS compared to ceMRI.

  1. Contrast-enhanced turbo spin-echo(TSE) T1-weighted imaging: improved contrast of enhancing lesions

    International Nuclear Information System (INIS)

    Choi, Sung Wook; Lee, Ghi Jai; Shim, Jae Chan; Lee, Young Ju; Jeong, Se Hyung; Kim, Ho kyun

    1997-01-01

    The purpose of this study was to evaluate the effect of contrast improvement of enhancing brain lesions by inherent magnetization transfer effect in turbo spin-echo(TSE)T1-weighted MR imaging. Twenty-six enhancing lesions of 19 patients were included in this study. Using a 1.0T superconductive MR unit, contrast-enhanced SE T1-weighted images(TR=3D600 msec, TE=3D12 msec, NEX=3D2, acquistition time=3D4min 27sec) and contrast-enhanced TSE T1-weighted images(TR=3D600 msec, TE=3D12, acquistition time=3D1min 44sec) were obtained. Signal intensities at enhancing lesions and adjacent white matter were measured in the same regions of both images. Signal-to-noise ratio(SNR) of enhancing lesions and adjacent white matter, and con-trast-to-noise ratio(CNR) and lesion-to-background contrast (LBC) of enhancing lesions were calculated and statistically analysed using the paired t-test. On contrast-enhanced TSE T1-weighted images, SNR of enhancing lesions and adjacent white matter decreased by 18%(p<0.01) and 32%(p<0.01), respectively, compared to contrast-enhanced SE T1-weighted images. CNR and LBC of enhancing lesions increased by 16%(p<0.05) and 66%(p<0.01), respectively. Due to the proposed inherent magnetization transfer effects in TSE imaging, con-trast-enhanced T1-weighted TSE images demonstrated a statistically significant improvement in CNR and LBC, compared to conventional contrast-enhanced T1-weighted SE images, and scan time was much shorter

  2. Facial nerve palsy: Evaluation by contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Kinoshita, T.; Ishii, K.; Okitsu, T.; Okudera, T.; Ogawa, T.

    2001-01-01

    AIM: The purpose of this study was to investigate the value of contrast-enhanced magnetic resonance (MR) imaging in patients with peripheral facial nerve palsy. MATERIALS AND METHODS: MR imaging was performed in 147 patients with facial nerve palsy, using a 1.0 T unit. All of 147 patients were evaluated by contrast-enhanced MR imaging and the pattern of enhancement was compared with that in 300 control subjects evaluated for suspected acoustic neurinoma. RESULTS: The intrameatal and labyrinthine segments of the normal facial nerve did not show enhancement, whereas enhancement of the distal intrameatal segment and the labyrinthine segment was respectively found in 67% and 43% of patients with Bell's palsy. The geniculate ganglion or the tympanic-mastoid segment was enhanced in 21% of normal controls versus 91% of patients with Bell's palsy. Abnormal enhancement of the non-paralyzed facial nerve was found in a patient with bilateral temporal bone fracture. CONCLUSION: Enhancement of the distal intrameatal and labyrinthine segments is specific for facial nerve palsy. Contrast-enhanced MR imaging can reveal inflammatory facial nerve lesions and traumatic nerve injury, including clinically silent damage in trauma. Kinoshita T. et al. (2001)

  3. Facial nerve palsy: Evaluation by contrast-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, T.; Ishii, K.; Okitsu, T.; Okudera, T.; Ogawa, T

    2001-11-01

    AIM: The purpose of this study was to investigate the value of contrast-enhanced magnetic resonance (MR) imaging in patients with peripheral facial nerve palsy. MATERIALS AND METHODS: MR imaging was performed in 147 patients with facial nerve palsy, using a 1.0 T unit. All of 147 patients were evaluated by contrast-enhanced MR imaging and the pattern of enhancement was compared with that in 300 control subjects evaluated for suspected acoustic neurinoma. RESULTS: The intrameatal and labyrinthine segments of the normal facial nerve did not show enhancement, whereas enhancement of the distal intrameatal segment and the labyrinthine segment was respectively found in 67% and 43% of patients with Bell's palsy. The geniculate ganglion or the tympanic-mastoid segment was enhanced in 21% of normal controls versus 91% of patients with Bell's palsy. Abnormal enhancement of the non-paralyzed facial nerve was found in a patient with bilateral temporal bone fracture. CONCLUSION: Enhancement of the distal intrameatal and labyrinthine segments is specific for facial nerve palsy. Contrast-enhanced MR imaging can reveal inflammatory facial nerve lesions and traumatic nerve injury, including clinically silent damage in trauma. Kinoshita T. et al. (2001)

  4. High-dose contrast-enhanced MRI in multiple sclerosis

    International Nuclear Information System (INIS)

    Koudriavtseva, T.; Pozzilli, C.; Di Biasi, C.; Iannilli, M.; Trasimeni, G.; Gasperini, C.; Argentino, C.; Gualdi, G.F.

    1996-01-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs

  5. High-dose contrast-enhanced MRI in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Koudriavtseva, T. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Pozzilli, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Di Biasi, C. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Iannilli, M. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Trasimeni, G. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy); Gasperini, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Argentino, C. [Department of Neurosciences, University of Rome ``La Sapienza`` Rome (Italy); Gualdi, G.F. [MR Unit, Clinica Medica 1, University of Rome ``La Sapienza``, Rome (Italy)

    1996-05-01

    Contrast-enhanced MRI is effective for assessing disease activity in multiple sclerosis (MS) and may provide an outcome measure for testing the efficacy of treatment in clinical trials. To compare the sensitivity of high-dose gadolinium-HP-DO3A with that of a standard dose of gadolinium-DTPA, we studied 16 patients with relapsing-remitting MS in the acute phase of the disease. Each underwent two MRI examinations within at most 48 h. The initial MRI study was with a standard dose of gadolinium-DTPA (0.1 mmol/kg), and the second one an experimental dose of gadolinium-HP-DO3A (0.3 mmol/kg). No adverse effects were attributed to the contrast media. The high-dose study revealed more enhancing lesions than the standard-dose study (56 vs 38). This difference was found to be more relevant for infratentorial and small lesions. Furthermore, with the higher dose, there was a marked qualitative improvement in the visibility and delineation of the lesions. (orig.). With 4 figs., 2 tabs.

  6. Contrast-enhanced swallow study sensitivity for anastomotic leak detection in post-esophagectomy patients.

    Science.gov (United States)

    Mejía-Rivera, S; Pérez-Marroquín, S A; Cortés-González, R; Medina-Franco, H

    2018-03-07

    Esophagectomy is a highly invasive surgery and one of its postoperative complications is anastomotic leakage, occurring in 53% of cases. The aim of the present study was to determine the sensitivity of the contrast-enhanced swallow study as a method for diagnosing anastomotic leak in patients that underwent esophagectomy. The present retrospective study included the case records of patients that underwent esophagectomy with reconstruction and cervical anastomosis at the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán within the time frame of January 1, 2000 and May 31, 2006. Demographic, clinical, and laboratory data emphasizing clinical and radiographic anastomotic leak detection were identified. Descriptive statistics were carried out and contrast-enhanced swallow study sensitivity for diagnosing leakage was calculated. Seventy patients were included in the analysis. The mean age of the patients was 50.6 years, 51 of the patients were men (72.86%), and 19 were women (27.14%). Indications for surgery were benign lesion in 29 patients (41.4%) and malignant lesion in 41 (58.6%). A total of 44.3% of the patients presented with a comorbidity, with diabetes mellitus and high blood pressure standing out. Thirty patients (42.85%) presented with anastomotic leak. Contrast-enhanced swallow study sensitivity for leak detection was 43.33%. The diagnostic sensitivity of the contrast-enhanced swallow study was very low. Therefore, we recommend the discontinuation of its routine use as a method for diagnosing anastomotic leaks. Copyright © 2018 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  7. A comparison of non-contrast and contrast-enhanced MRI in the initial stage of Legg-Calve-Perthes disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Harry K.W. [Texas Scottish Rite Hospital for Children, Center of Excellence in Hip Disorders, Dallas, TX (United States); University of Texas Southwestern, Department of Orthopedic Surgery, Dallas, TX (United States); Kaste, Sue [St. Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States); St. Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States); University of Tennessee School of Health Sciences, Department of Radiology, Memphis, TN (United States); Dempsey, Molly; Wilkes, David [Texas Scottish Rite Hospital for Children, Department of Radiology, Dallas, TX (United States)

    2013-09-15

    A prognostic indicator of outcome for Legg-Calve-Perthes disease (LCP) is needed to guide treatment decisions during the initial stage of the disease (stage 1), before deformity occurs. Radiographic prognosticators are applicable only after fragmentation (stage II). We investigated pre- and postcontrast MRI in depicting stage I femoral head involvement. Thirty children with stage I LCP underwent non-contrast coronal T1 fast spin-echo (FSE) and corresponding postcontrast fat-suppressed T1-weighted fast spin-echo (FSE) sequences to quantify the extent of femoral head involvement. Three pediatric radiologists and one pediatric orthopedic surgeon independently measured central head involvement. Interobserver reliability of percent head involvement using non-contrasted MR images had intraclass correlation coefficient (ICC) of 0.72. Postcontrast MRI improved interobserver reliability (ICC 0.82). Qualitatively, the area of involvement was more clearly visible on contrast-enhanced MRI. A comparison of results obtained by each observer using the two MRI techniques showed no correlation. ICC ranged from -0.08 to 0.03 for each observer. Generally, greater head involvement was depicted by contrast compared with non-contrast MRI (Pearson r = -0.37, P = 0.04). Pre- and postcontrast MRI assess two different components of stage I LCP. However, contrast-enhanced MRI more clearly depicts the area of involvement. (orig.)

  8. Indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced computed tomography: Assessment of the additional diagnostic value of contrast-enhanced ultrasound in the non-cirrhotic liver

    International Nuclear Information System (INIS)

    Quaia, Emilio; De Paoli, Luca; Angileri, Roberta; Cabibbo, Biagio; Cova, Maria Assunta

    2014-01-01

    Objective: To assess the additional diagnostic value of contrast-enhanced ultrasound (CEUS) in the characterization of indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced computed tomography (CT). Methods: Fifty-five solid hepatic lesions (1–4 cm in diameter) in 46 non-cirrhotic patients (26 female, 20 male; age ± SD, 55 ± 10 years) underwent CEUS after being detected on contrast-enhanced CT which was considered as non-diagnostic after on-site analysis. Two blinded independent readers assessed CT and CEUS scans and were asked to classify retrospectively each lesion as a malignant or benign based on reference diagnostic criteria for the different hepatic lesion histotypes. Diagnostic accuracy and confidence (area – A z – under ROC curve) were assessed by using gadobenate dimeglumine-enhanced magnetic resonance (MR) imaging (n = 30 lesions), histology (n = 7 lesions), or US follow-up (n = 18 lesions) as the reference standards. Results: Final diagnoses included 29 hemangiomas, 3 focal nodular hyperplasias, 1 hepatocellular adenoma, and 22 metastases. The additional review of CEUS after CT images improved significantly (P < .05) the diagnostic accuracy (before vs after CEUS review = 49% [20/55] vs 89% [49/55] – reader 1 and 43% [24/55] vs 92% [51/55] – reader 2) and confidence (A z , 95% Confidence Intervals before vs after CEUS review = .773 [.652–.895] vs .997 [.987–1] – reader 1 and .831 [.724–.938] vs .998 [.992–1] – reader 2). Conclusions: CEUS improved the characterization of indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced CT by identifying some specific contrast enhancement patterns.

  9. Therapeutic response assessment of high intensity focused ultrasound therapy for uterine fibroid: Utility of contrast-enhanced ultrasonography

    International Nuclear Information System (INIS)

    Zhou Xiaodong; Ren Xiaolong; Zhang Jun; He Guangbin; Zheng Minjuan; Tian Xue; Li Li; Zhu Ting; Zhang Min; Wang Lei; Luo Wen

    2007-01-01

    Purpose: To assess the utility of contrast-enhanced ultrasonography (ceUS) in the assessment of the therapeutic response to high intensity focused ultrasound (HIFU) ablation in patients with uterine fibroid. Materials and methods: Sixty-four patients with a total of 64 uterine fibroids (mean: 5.3 ± 1.2 cm; range: 3.2-8.9 cm) treated with HIFU ablation under the ultrasound guidance were evaluated with ceUS after receiving an intravenous bolus injection of a microbubble contrast agent (SonoVue) within 1 week after intervention. We obtained serial ceUS images during the time period from beginning to 5 min after the initiation of the bolus contrast injection. All of the patients underwent a contrast enhanced MRI (ceMRI) and ultrasound guided needle puncture biopsy within 1 week after HIFU ablation. And as a follow-up, all of the patients underwent US at 1, 3, 6 and 12 months after HIFU treatment. The volume change was observed and compared to pre- and post-HIFU ablation. The results of the ceUS were compared with those of the ceMRI in terms of the presence or absence of residual unablated tumor and pathologic change in the treated lesions. Results: On ceUS, diagnostic accuracy was 100%, while residual unablated tumors were found in three uterine fibroids (4.7%) and failed treatment was found in eight uterine fibroids (12.5%). All the 11 fibroids were subjected to additional HIFU ablation. Of the 58 ablated fibroids without residual tumors on both the ceUS and ceMRI after the HIFU ablation, the volumes of all the fibroids decreased in different degrees during the 1 year follow-up USs. And histologic examinations confirmed findings of necrotic and viable tumor tissue, respectively. Conclusion: CEUS is potentially useful for evaluating the early therapeutic effect of percutaneous HIFU ablation for uterine fibroids

  10. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... initially used as Doppler signal enhancers, second-generation microbubble contrast agents are now used with specific contrast harmonic imaging techniques, which benefit from the highly nonlinear behavior of the microbubbles. Contrast-specific modes based on multi-pulse technology are used to perform...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  11. Contrast-enhanced ultrasonography for the determination of Crohn's disease activity - preliminary experience.

    Science.gov (United States)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Kłopocka, Maria; Liebert, Ariel; Lemanowicz, Adam; Serafin, Zbigniew

    2014-01-01

    Contrast-enhanced ultrasound (CEUS) is a recent non-invasive modality, which may partially replace currently used techniques (endoscopy, CT enterography and MR enterography) in the diagnostics and assessment of Crohn's disease (CD). The aim of the study was to analyze early experience in the use of CEUS for the measurement of activity and staging of CD. Eleven patients previously diagnosed with CD were included in the study. They underwent contrast-enhanced ultrasonography (SonoVue, Bracco), low-dose CT enterography (LDCTE), assessment of laboratory markers of inflammation and clinical CD activity index (CDAI). Contrast enhancement was evaluated using a semi-quantitative method and a quantitative method that included measurement of peak enhancement (PE), enhancement curve rise time (RT) and wash-in-rate (WiR). Ileal wall thickening was observed in all patients. Semi-quantitative method was used to observe CD activity in CEUS in 10 cases that perfectly matched LDCTE findings. There was a moderate positive correlation between PE and CDAI (r=0.65, p<0.001). There was no significant relationship between perfusion parameters and laboratory markers of inflammation. CEUS is a promising modality for non-invasive assessment of pathologic ileal vascularization in the course of Crohn's disease. Intensity of enhancement in CEUS reflects activity of the disease detected in LDCTE and correlates with CDAI.

  12. Contrast Enhanced US in the Abdomen

    International Nuclear Information System (INIS)

    Chung, Yong Eun; Kim, Ki Whang

    2012-01-01

    Contrast enhanced ultrasound, which was introduced in 1996, has been widely used in Europe and Eastern Asia. Ultrasound contrast agent can be classified as first generation and second generation, depending on the gas within the microbubble. With the first generation contrast agent, the high MI technique was used, and only intermittent scanning was possible due to destruction of the microbubble during scanning. Use of the second generation contrast agent with the low MI technique makes continuous scanning possible. Contrast enhanced US can be used in detection and differentiation of focal liver lesions. It is also helpful for monitoring of radiofrequency ablation and for targeting of US guided biopsy. Currently, because morphologic criteria alone may not reflect the response of the tumor to treatment, new criteria are needed for treatment evaluation after administration of anti-angiogenic agents. Contrast enhanced US could provide quantitative markers for evaluation of the response to treatment via use of dynamic contrast enhanced US. Due to cost-effectiveness, contrast enhanced US is not yet widely used in Korea; however, considering recent issues regarding contrast agent related adverse reaction, such as contrast induced nephropathy and nephrogenic systemic fibrosis, and radiation exposure, contrast enhanced US might be more widely used in Korea, as an alternative imaging modality in the future.

  13. Dynamic Contrast-Enhanced Magnetic Resonance Enterography and Dynamic Contrast-Enhanced Ultrasonography in Crohn's Disease

    DEFF Research Database (Denmark)

    Wilkens, Rune; Peters, David A; Nielsen, Agnete Hedemann

    2017-01-01

    Purpose e Cross-sectional imaging methods are important for objective evaluationof small intestinal inflammationinCrohn'sdisease(CD).The primary aim was to compare relative parameters of intestinal perfusion between contrast-enhanced ultrasonography (CEUS) and dynamic contrast-enhanced magnetic...

  14. Subtraction MR venography acquired from time-resolved contrast-enhanced MR angiography: Comparison with phase-contrast MR venography and single-phase contrast-enhanced MR venography

    International Nuclear Information System (INIS)

    Jang, Jin Hee; Kim, Bum Soo; KIm, Bom Yi; Choi, Hyun Seok; Jung, So Lyung; Ahn, Kook Jin; Sung, Ji Kyeong

    2015-01-01

    To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). Subtraction magnetic

  15. A prospective study on the risk of contrast induced nephropathy in the patients who underwent contrast-enhanced CT examination

    International Nuclear Information System (INIS)

    Zhang Baocui; Zhang Yudong; Zhao Kai; Wang Xiaoying; Jiang Xuexiang

    2013-01-01

    Objective: To investigate the incidence of contrast induced nephropathy (CIN) among different patient groups after contrast agent injection. Methods: A total of 1243 patients were included in this study (male = 694, female = 549). The SCr level one week before and 72 hours after the CT examination and the incidence of CIN were recorded and comparison was made among groups according to sex, age, body mass index (BMI), the history of high blood pressure (HBP), diabetes mellitus (DM), chronic kidney disease (CKD), chronic heart failure (CHF), tumor, nephrotoxicity drug (NTD) usage. The frequency, type, dose and injection velocity of the contrast media (CM) were also recorded. Multivariate predictors of CIN were identified by Logistic regression using step-wise selection with entry and exit criteria of P 1). Conclusion: Women, age ≥ 75 years, LOCM, NTD, tumor, and the frequency of using CM more than once per month were more likely to develop CIN. (authors)

  16. The significance of delayed contrast-enhanced CT in chronic subdural hematomas

    International Nuclear Information System (INIS)

    Karasawa, Hideharu; Ohya, Shigeru; Ueno, Junji; Watanabe, Saburo; Mikabe, Toshio

    1983-01-01

    We have previously, reported our delayed contrast-enhanced CT (DCECT) findings in traumatic subdural hygromas and chronic subdural hematomas. The purpose of this report is to clarify the relationship between the contrast media within subdural hematomas and the delayed enhancement. The clinical subjects were 35 cases of traumatic subdural hematomas. DCECT examinations were performed in all cases. The concentrations of the contrast media within the hematoma were measured during the operations. DCECT showed that the density of the hematomas increased 3 to 6 hours after the injection of the contrast media. The contrast media were detected within the hematomas a few hours after the injection. The contrast media were still present 24 hours after the injection, but disappeared in 48 hours. These findings suggest that contrast media go in and then come out of the subdural hematomas and that the main factor related to delayed enhancement is the concentration of the contrast media within the hematomas. DCECT examination may be most helpful in evaluating the dynamic changes in subdural collections. (author)

  17. Magnetic Resonance Imaging Susceptibility-Weighted Imaging Lesion and Contrast Enhancement May Represent Infectious Intracranial Aneurysm in Infective Endocarditis.

    Science.gov (United States)

    Cho, Sung-Min; Rice, Cory; Marquardt, Robert J; Zhang, Lucy Q; Khoury, Jean; Thatikunta, Prateek; Buletko, Andrew B; Hardman, Julian; Uchino, Ken; Wisco, Dolora

    2017-01-01

    Infectious intracranial aneurysm (IIA) can complicate infective endocarditis (IE). We aimed to describe the magnetic resonance imaging (MRI) characteristics of IIA. We reviewed IIAs among 116 consecutive patients with active IE by conducting a neurological evaluation at a single tertiary referral center from January 2015 to July 2016. MRIs and digital cerebral angiograms (DSA) were reviewed to identify MRI characteristics of IIAs. MRI susceptibility weighted imaging (SWI) was performed to collect data on cerebral microbleeds (CMBs) and sulcal SWI lesions. Out of 116 persons, 74 (63.8%) underwent DSA. IIAs were identified in 13 (17.6% of DSA, 11.2% of entire cohort) and 10 patients with aneurysms underwent MRI with SWI sequence. Nine (90%) out of 10 persons with IIAs had CMB >5 mm or sulcal lesions in SWI (9 in sulci, 6 in parenchyma, and 5 in both). Five out of 8 persons who underwent MRI brain with contrast had enhancement within the SWI lesions. In a multivariate logistic regression analysis, both sulcal SWI lesions (p < 0.001, OR 69, 95% CI 7.8-610) and contrast enhancement (p = 0.007, OR 16.5, 95% CI 2.3-121) were found to be significant predictors of the presence of IIAs. In the individuals with IE who underwent DSA and MRI, we found that neuroimaging characteristics, such as sulcal SWI lesion with or without contrast enhancement, are associated with the presence of IIA. © 2017 S. Karger AG, Basel.

  18. Medial tibial pain: a dynamic contrast-enhanced MRI study.

    Science.gov (United States)

    Mattila, K T; Komu, M E; Dahlström, S; Koskinen, S K; Heikkilä, J

    1999-09-01

    The purpose of this study was to compare the sensitivity of different magnetic resonance imaging (MRI) sequences to depict periosteal edema in patients with medial tibial pain. Additionally, we evaluated the ability of dynamic contrast-enhanced imaging (DCES) to depict possible temporal alterations in muscular perfusion within compartments of the leg. Fifteen patients with medial tibial pain were examined with MRI. T1-, T2-weighted, proton density axial images and dynamic and static phase post-contrast images were compared in ability to depict periosteal edema. STIR was used in seven cases to depict bone marrow edema. Images were analyzed to detect signs of compartment edema. Region-of-interest measurements in compartments were performed during DCES and compared with controls. In detecting periosteal edema, post-contrast T1-weighted images were better than spin echo T2-weighted and proton density images or STIR images, but STIR depicted the bone marrow edema best. DCES best demonstrated the gradually enhancing periostitis. Four subjects with severe periosteal edema had visually detectable pathologic enhancement during DCES in the deep posterior compartment of the leg. Percentage enhancement in the deep posterior compartment of the leg was greater in patients than in controls. The fast enhancement phase in the deep posterior compartment began slightly slower in patients than in controls, but it continued longer. We believe that periosteal edema in bone stress reaction can cause impairment of venous flow in the deep posterior compartment. MRI can depict both these conditions. In patients with medial tibial pain, MR imaging protocol should include axial STIR images (to depict bone pathology) with T1-weighted axial pre and post-contrast images, and dynamic contrast enhanced imaging to show periosteal edema and abnormal contrast enhancement within a compartment.

  19. Contrast-enhanced ultra-high-field liver MRI: A feasibility trial

    Energy Technology Data Exchange (ETDEWEB)

    Umutlu, Lale, E-mail: Lale.Umutlu@uk-essen.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Bitz, Andreas K.; Maderwald, Stefan; Orzada, Stephan; Kinner, Sonja; Kraff, Oliver; Brote, Irina; Ladd, Susanne C.; Schroeder, Tobias; Forsting, Michael; Antoch, Gerald; Ladd, Mark E. [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Quick, Harald H. [Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Institute of Medical Physics, University Nuernberg-Erlangen (Germany); Lauenstein, Thomas C. [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany)

    2013-05-15

    The aim of this study was to investigate the feasibility of dynamic contrast-enhanced 7 T MRI of the liver using an eight-channel radiofrequency (RF) transmit/receive body-coil. 16 healthy subjects were examined on a 7 T MR system utilizing a custom-built eight-channel RF body-coil suitable for RF-shimming. The following data were acquired: (1) steady state free precession imaging, (2) T2w turbo spin echo imaging, (3) T1w in and opposed-phase imaging, (4) T1w 3D FLASH images pre-contrast and in arterial, portal-venous and venous phase and (5) a fat-saturated pre- and post-contrast 2D FLASH sequence. Visual evaluation of (1) the delineation of liver vasculature, (2) the overall image quality, and (3) artifact presence and consequent image impairment was performed. SNR of the liver parenchyma was measured for the contrast-enhanced 2D and 3D FLASH sequences. For statistical analysis, a Wilcoxon-Rank Test was used. Best delineation of non-enhanced liver vasculature and overall image quality was found for 2D FLASH MRI, with only slight improvement in vessel conspicuity after the application of contrast media. T2-weighted TSE imaging remained strongly impaired, falling short of diagnostic relevance and precluding a clinical application. Our results demonstrate the feasibility and diagnostic potential of dedicated contrast-enhanced 7 T liver MRI as well as the potential for non-contrast-enhanced angiographic application.

  20. Dynamic contrast-enhanced magnetic resonance imaging of the wrist in children with juvenile idiopathic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Nusman, Charlotte M. [Emma Children' s Hospital, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Academic Medical Center, Amsterdam (Netherlands); Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Lavini, Cristina; Hemke, Robert; Caan, Matthan W.A.; Maas, Mario [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Schonenberg-Meinema, Dieneke; Berg, J.M. van den; Kuijpers, Taco W. [Emma Children' s Hospital, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Academic Medical Center, Amsterdam (Netherlands); Dolman, Koert M. [Sint Lucas Andreas Hospital, Department of Pediatrics, Amsterdam (Netherlands); Reade Institute location Jan van Breemen, Department of Pediatric Rheumatology, Amsterdam (Netherlands); Rossum, Marion A.J. van [Reade Institute location Jan van Breemen, Department of Pediatric Rheumatology, Amsterdam (Netherlands); Emma Children' s Hospital, Department of Pediatrics, Academic Medical Center, Amsterdam (Netherlands)

    2017-02-15

    Dynamic contrast-enhanced MRI provides information on the heterogeneity of the synovium, the primary target of disease in children with juvenile idiopathic arthritis (JIA). To evaluate the feasibility of dynamic contrast-enhanced MRI in the wrist of children with JIA using conventional descriptive measures and time-intensity-curve shape analysis. To explore the association between enhancement characteristics and clinical disease status. Thirty-two children with JIA and wrist involvement underwent dynamic contrast-enhanced MRI with movement-registration and were classified using validated criteria as clinically active (n = 27) or inactive (n = 5). Outcome measures included descriptive parameters and the classification into time-intensity-curve shapes, which represent the patterns of signal intensity change over time. Differences in dynamic contrast-enhanced MRI outcome measures between clinically active and clinically inactive disease were analyzed and correlation with the Juvenile Arthritis Disease Activity Score was determined. Comprehensive evaluation of disease status was technically feasible and the quality of the dynamic dataset was improved by movement registration. The conventional descriptive measure maximum enhancement differed significantly between clinically active and inactive disease (P = 0.019), whereas time-intensity-curve shape analysis showed no differences. Juvenile Arthritis Disease Activity Score correlated moderately with enhancing volume (P = 0.484). Dynamic contrast-enhanced MRI is a promising biomarker for evaluating disease status in children with JIA and wrist involvement. Conventional descriptive dynamic contrast-enhanced MRI measures are better associated with clinically active disease than time-intensity-curve shape analysis. (orig.)

  1. Topical contrast-enhanced magnetic resonance dacryocystography

    International Nuclear Information System (INIS)

    Yoshikawa, Takeshi; Sugimura, Kazuro; Hirota, Shozo

    2000-01-01

    The purpose of this study was to evaluate the usefulness of magnetic resonance dacryocystography (MRD) with topical administration of normal saline solution and diluted Gd-DTPA solution for the assessment of lacrimal outflow disorders. Two T2-weighted sequences and two T1-weighted sequences were evaluated in this study. The 1:100 diluted Gd solution was prepared by diluting Gd-DTPA (Magnevist) with normal saline solution. A phantom study using tube phantoms of various diameters filled with normal saline solution and 1:100 diluted Gd solution was performed. A preliminary study was performed in ten normal volunteers Eighteen patients with lacrimal outflow disorders underwent clinical MRD, and 14 also underwent conventional dacryocystography (CDG). MRD images were evaluated and compared with clinical symptoms and CDG images. In all sequences, MRD could visualize the full length of 0.7 to 1.7 mm diameter tube phantoms and could show all of the normal lacrimal sacs and nasolacrimal ducts. In the clinical study, MRD findings were compatible with the symptoms in 14 patients but were not compatible with CDG findings in half of the cases. Topical contrast-enhanced MRD provided a simple, non-invasive means of obtaining detailed morphological and functional information on the lacrimal drainage apparatus. (author)

  2. Contrast-enhanced ultrasound imaging of active bleeding associated with hepatic and splenic trauma.

    Science.gov (United States)

    Lv, F; Tang, J; Luo, Y; Li, Z; Meng, X; Zhu, Z; Li, T

    2011-10-01

    The aim of this study was to evaluate contrast-enhanced ultrasound (CEUS) imaging of active bleeding from hepatic and splenic trauma. Three hundred and ninety-two patients with liver or/and spleen trauma (179 liver and 217 spleen injuries), who underwent CEUS examinations following contrast-enhanced computed tomography (CT), were enrolled in this retrospective study over a period of >4 years. CEUS detected contrast medium extravasation or pooling in 16% (63/396) of liver or spleen lesions in 61 patients, which was confirmed by contrast-enhanced CT. Special attention was paid to observing the presence, location, and characteristics of the extravasated or pooled contrast medium. The CEUS detection rate for active bleeding was not different from that of contrast-enhanced CT (p=0.333). Information from surgery, minimally invasive treatment and conservative treatment was used as reference standard, and the sensitivities of the two techniques were not different (p=0.122). Of 63 lesions in 61 patients, CEUS showed that 74.6% (47/63) (21 liver lesions and 26 spleen lesions) presented contrast medium extravasation or pooling, both in the organ and out the capsule, in 14.3% (9/63) and only outside the capsule in 11.1% (7/63). CEUS imaging of active bleeding from hepatic and splenic trauma presented various characteristics, and the sizes and shapes of the active bleeding due to contrast medium extravasation or pooling were variable. CEUS can show the active bleeding associated with hepatic and splenic trauma with various imaging characteristics, thus making it possible to diagnose active bleeding using CEUS.

  3. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography

    Directory of Open Access Journals (Sweden)

    Rodrigo da Fonseca Monjardim

    2013-06-01

    Full Text Available Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity.

  4. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography

    International Nuclear Information System (INIS)

    Monjardim, Rodrigo da Fonseca; Costa, Danilo Manuel Cerqueira; Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Santos, Jaime de Vargas Conde dos; Atzingen, Augusto Castelli Von; Shigueoka, David Carlos; D'Ippolito, Giuseppe

    2013-01-01

    Objective: to evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and methods: in the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results: the simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion: The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity. (author)

  5. Prospective evaluation of contrast-enhanced MR imaging after uncomplicated lumbar discography

    International Nuclear Information System (INIS)

    Carrino, John A.; Swathwood, Todd C.; Morrison, William B.; Glover, J.M.

    2007-01-01

    Postdiscography infection is an uncommon complication. Magnetic resonance (MR) imaging is often the modality of choice for evaluating spinal infection. Discography entails disc access and fluid injection that could alter the baseline MR imaging appearance of the spine and be confounded for infection. Our purpose was to describe the MR imaging findings of the lumbar spine subsequent to uncomplicated discography and to determine if this may mimic infection. In a prospective cohort study of eight adults (age 22-64 years, mean 45 years) with 22 intradiscal injections, all subjects underwent routine unenhanced and contrast-enhanced MR imaging during the 2-3 week interval postdiscography. A subset of four returned for additional MR imaging during the 4-8 week interval postdiscography. MR images were reviewed for intradiscal, endplate, marrow, and epidural findings and then compared with prediscography examinations. Infection was excluded by clinical documentation. Postdiscography MR imaging showed that almost all levels were similar to baseline prediscography examinations. No levels developed new vertebral marrow edema, fluid-like intradiscal signal, endplate irregularity, or epidural abnormality. Two subjects simulated potential discitis, but these findings were unchanged from prediscography and were related to prior surgery. Uncomplicated lumbar spine discography does not cause MR imaging changes that simulate discitis. (orig.)

  6. Prospective evaluation of contrast-enhanced MR imaging after uncomplicated lumbar discography

    Energy Technology Data Exchange (ETDEWEB)

    Carrino, John A. [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins Outpatient Center, Baltimore, MD (United States); Swathwood, Todd C. [Blue Ridge Orthopedic Associates, Seneca (United States); Morrison, William B. [Thomas Jefferson University Hospital, Department of Radiology, Philadelphia, PA (United States); Glover, J.M. [Northern Arizona Orthopaedics, Flagstaff, AZ (United States)

    2007-04-15

    Postdiscography infection is an uncommon complication. Magnetic resonance (MR) imaging is often the modality of choice for evaluating spinal infection. Discography entails disc access and fluid injection that could alter the baseline MR imaging appearance of the spine and be confounded for infection. Our purpose was to describe the MR imaging findings of the lumbar spine subsequent to uncomplicated discography and to determine if this may mimic infection. In a prospective cohort study of eight adults (age 22-64 years, mean 45 years) with 22 intradiscal injections, all subjects underwent routine unenhanced and contrast-enhanced MR imaging during the 2-3 week interval postdiscography. A subset of four returned for additional MR imaging during the 4-8 week interval postdiscography. MR images were reviewed for intradiscal, endplate, marrow, and epidural findings and then compared with prediscography examinations. Infection was excluded by clinical documentation. Postdiscography MR imaging showed that almost all levels were similar to baseline prediscography examinations. No levels developed new vertebral marrow edema, fluid-like intradiscal signal, endplate irregularity, or epidural abnormality. Two subjects simulated potential discitis, but these findings were unchanged from prediscography and were related to prior surgery. Uncomplicated lumbar spine discography does not cause MR imaging changes that simulate discitis. (orig.)

  7. Baseline incidence and severity of renal insufficiency evaluated by estimated glomerular filtration rates in patients scheduled for contrast-enhanced CT

    International Nuclear Information System (INIS)

    Utsunomiya, Daisuke; Yanaga, Yumi; Oda, Seitaro; Namimoto, Tomohiro; Yamashita, Yasuyuki; Awai, Kazuo; Funama, Yoshinori

    2011-01-01

    Background Although pre-existing renal insufficiency (RI) is the most important risk factor for contrast-induced nephropathy (CIN), the background distribution of baseline renal function has not been investigated thoroughly in patients scheduled for contrast-enhanced CT. Purpose To investigate the incidence and severity of baseline RI evaluated by estimated glomerular filtration rates (eGFR) in patients who underwent contrast-enhanced CT at an academic center. Material and Methods A total of 6586 patients (3630 men and 2956 women; mean age 57.0 ± 11.9 years) who underwent contrast-enhanced CT between January and December 2008 were retrospectively studied. Of these, 829 had cardiovascular diseases (CVD), 5116 had oncologic diseases, 178 had diabetes mellitus (DM), and 1572 had chronic liver disease (CLD). The eGFR (mL/min/1.73 m 2 ) was calculated from their serum creatinine level. Mild, moderate-a, moderate-b, and severe RI were recorded at 60 2 at baseline was high in patients with advanced age, CVD and DM and in patients without oncologic disease

  8. Technical innovation in dynamic contrast-enhanced magnetic resonance imaging of musculoskeletal tumors: an MR angiographic sequence using a sparse k-space sampling strategy.

    Science.gov (United States)

    Fayad, Laura M; Mugera, Charles; Soldatos, Theodoros; Flammang, Aaron; del Grande, Filippo

    2013-07-01

    We demonstrate the clinical use of an MR angiography sequence performed with sparse k-space sampling (MRA), as a method for dynamic contrast-enhanced (DCE)-MRI, and apply it to the assessment of sarcomas for treatment response. Three subjects with sarcomas (2 with osteosarcoma, 1 with high-grade soft tissue sarcomas) underwent MRI after neoadjuvant therapy/prior to surgery, with conventional MRI (T1-weighted, fluid-sensitive, static post-contrast T1-weighted sequences) and DCE-MRI (MRA, time resolution = 7-10 s, TR/TE 2.4/0.9 ms, FOV 40 cm(2)). Images were reviewed by two observers in consensus who recorded image quality (1 = diagnostic, no significant artifacts, 2 = diagnostic, 75 % with good response, >75 % with poor response). DCE-MRI findings were concordant with histological response (arterial enhancement with poor response, no arterial enhancement with good response). Unlike conventional DCE-MRI sequences, an MRA sequence with sparse k-space sampling is easily integrated into a routine musculoskeletal tumor MRI protocol, with high diagnostic quality. In this preliminary work, tumor enhancement characteristics by DCE-MRI were used to assess treatment response.

  9. Usefulness of dynamic contrast-enhanced MRI in the evaluation of the viability of acute scaphoid fracture

    Energy Technology Data Exchange (ETDEWEB)

    Larribe, Maud [Hopital La Conception, Service d' imagerie medicale, Marseille (France); Hopital Sainte Marguerite, Service d' imagerie medicale, Marseille (France); Gay, Andre [Hopital La Conception, Service de chirurgie de la main, Marseille (France); Freire, Veronique [Centre hospitalier de l' Universite de Montreal, Department of Radiology, Notre-Dame Hospital, Montreal, QC (Canada); Bouvier, Corinne [Hopital La Timone, Service d' anatomopathologie, Marseille (France); Chagnaud, Christophe; Souteyrand, Philippe [Hopital La Conception, Service d' imagerie medicale, Marseille (France)

    2014-12-15

    To evaluate the usefulness of dynamic gadolinium-enhanced magnetic resonance imaging (MRI) for assessing the viability of the proximal pole of the scaphoid in patients with acute scaphoid fractures. Eighteen consecutive patients with acute scaphoid fracture who underwent dynamic gadolinium-enhanced MRI 7 days or less before surgery were prospectively included between August 2011 and December 2012. All patients underwent MR imaging with unenhanced images, enhanced images, and dynamic enhanced images. A radiologist first classified the MRI results as necrotic or viable based on T1- and T2-weighted images only, followed by a second blinded interpretation, this time including analysis of pre- and post-gadolinium administration images and a third blinded interpretation based on the time-intensity curve of the dynamic enhanced study. The standard of reference was the histologic assessment of a cylindrical specimen of the proximal pole obtained during surgery in all patients. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for unenhanced, enhanced, and dynamic gadolinium-enhanced MRI studies. The sensitivity, specificity, PPV, and NPV were 67, 67, 50, and 80 % for unenhanced images, 83, 100, 100, and 92 for enhanced images, and 83, 92, 83, and 92 for dynamic contrast-enhanced images. Our data are consistent with previously reported data supporting contrast-enhanced MRI for assessment of viability, and showing that dynamic imaging with time-intensity curve analysis does not provide additional predictive value over standard delayed enhanced imaging for acute scaphoid fracture. (orig.)

  10. Usefulness of dynamic contrast-enhanced MRI in the evaluation of the viability of acute scaphoid fracture

    International Nuclear Information System (INIS)

    Larribe, Maud; Gay, Andre; Freire, Veronique; Bouvier, Corinne; Chagnaud, Christophe; Souteyrand, Philippe

    2014-01-01

    To evaluate the usefulness of dynamic gadolinium-enhanced magnetic resonance imaging (MRI) for assessing the viability of the proximal pole of the scaphoid in patients with acute scaphoid fractures. Eighteen consecutive patients with acute scaphoid fracture who underwent dynamic gadolinium-enhanced MRI 7 days or less before surgery were prospectively included between August 2011 and December 2012. All patients underwent MR imaging with unenhanced images, enhanced images, and dynamic enhanced images. A radiologist first classified the MRI results as necrotic or viable based on T1- and T2-weighted images only, followed by a second blinded interpretation, this time including analysis of pre- and post-gadolinium administration images and a third blinded interpretation based on the time-intensity curve of the dynamic enhanced study. The standard of reference was the histologic assessment of a cylindrical specimen of the proximal pole obtained during surgery in all patients. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for unenhanced, enhanced, and dynamic gadolinium-enhanced MRI studies. The sensitivity, specificity, PPV, and NPV were 67, 67, 50, and 80 % for unenhanced images, 83, 100, 100, and 92 for enhanced images, and 83, 92, 83, and 92 for dynamic contrast-enhanced images. Our data are consistent with previously reported data supporting contrast-enhanced MRI for assessment of viability, and showing that dynamic imaging with time-intensity curve analysis does not provide additional predictive value over standard delayed enhanced imaging for acute scaphoid fracture. (orig.)

  11. Effects of computed tomography contrast medium factors on contrast enhancement

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi; Okuda, Itsuko

    2011-01-01

    The various nonionic iodinated contrast media used in contrast computed tomography (CT) studies differ in terms of their composition, characteristics, and iodine concentration (mgI/ml), as well as the volume injected (ml). Compared with ionic iodinated contrast media, nonionic iodinated contrast media are low-osmolar agents, with different agents having different osmotic pressures. Using a custom-made phantom incorporating a semipermeable membrane, the osmotic flow rate (hounsfield unit (HU)/s) could easily be measured based on the observed increase in CT numbers, and the relationship between the osmotic pressure and the osmotic flow rate could be obtained (r 2 =0.84). In addition, taking the effects of patient size into consideration, the levels of contrast enhancement in the abdominal aorta (AA) and inferior vena cava (IVC) were compared among four types of CT contrast medium. The results showed differences in contrast enhancement in the IVC during the equilibrium phase depending on the type of contrast medium used. It was found that the factors responsible for the differences observed in enhancement in the IVC were the osmotic flow rate and the volume of the blood flow pathways in the circulatory system. It is therefore considered that the reproducibility of contrast enhancement is likely to be reduced in the examination of parenchymal organs, in which scanning must be performed during the equilibrium phase, even if the amount of iodine injected per unit body weight (mgI/kg) is maintained at a specified level. (author)

  12. Prognostic value of contrast-enhanced MR mammography in patients with breast cancer.

    Science.gov (United States)

    Fischer, U; Kopka, L; Brinck, U; Korabiowska, M; Schauer, A; Grabbe, E

    1997-01-01

    The objective of this study was to evaluate the prognostic value of contrast-enhanced MR mammography in patients with breast cancer. A total of 190 patients with breast cancer (37 noninvasive carcinomas, 153 invasive carcinomas) underwent dynamic contrast-enhanced MR mammography preoperatively. Using 1.5-T unit, T1-weighted sequences (2D FLASH) were obtained repeatedly one time before and five times after IV administration of 0.1 mmol gadopentetate-dimeglumine per kilogram body weight. The findings on MR imaging were correlated with histopathologically defined prognostic factors (histological type, tumor size, tumor grading, metastasis in lymph nodes). In addition, immunohistochemically defined prognostic factors (c-erbB-1, c-erbB-2, p53, Ki-67) were correlated with the signal increase on MR mammogram in 40 patients. There was no significant correlation between the findings on MR mammography and the histopathological type of carcinoma, the grading, and the lymphonodular status. Noninvasive carcinomas showed a higher rate of moderate (38 %) or low (27 %) enhancement on MR imaging than invasive carcinomas (6 and 3 %). The results on MR mammography and the results of immunohistochemical stainings did not correlate significantly. Noninvasive carcinomas showed significantly lower enhancement than invasive carcinomas. However, the signal behavior of contrast-enhanced MR mammography is not related to established histopathological prognostic parameters as subtyping, grading, nodal status, and the expression of certain oncogenes/tumor suppressor genes.

  13. Contrast enhanced CT of spinal cord angioma

    International Nuclear Information System (INIS)

    Nakamura, Takahiko; Ebitani, Tsutomu; Honma, Takao; Sofue, Muroto; Nakamura, Shigeru

    1982-01-01

    Contrast enhanced CT on 6 patients with spinal cord angioma showed enhancement in 2 of them. The conditions to produce contrast enhancement were the window width of 100 - 200, and the window level of 0 - 50. In spinal cord angioma, contrast enhanced CT is presently only an adjunct to angiography and myelography. Nevertheless, contrast enhanced CT is useful in the screening test for spinal cord angioma, in the patients who are nonindicated to angiography, and in the postoperative follow-up. (Ueda, J.)

  14. Acetabular labral tears: contrast-enhanced MR imaging under continuous leg traction

    Energy Technology Data Exchange (ETDEWEB)

    Nishii, T. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Nakanishi, K. [Dept. of Radiology, Osaka Univ. Medical School, Suita (Japan); Sugano, N. [Dept. of Orthopaedic Surgery, Osaka Univ. Medical School, Suita (Japan); Naito, H. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Tamura, S. [Div. of Functional Diagnostic Imaging, Biomedical Research Center, Osaka Univ. Medical School, Suita (Japan); Ochi, T. [Dept. of Orthopaedic Surgery, Osaka Univ. Medical School, Suita (Japan)

    1996-05-01

    The objective of this study was to evaluate the effects of continuous leg traction on contrast-enhanced MR imaging of the hip joint and to determine whether MR imaging under these conditions is useful for demonstrating acetabular labral tears. Nineteen hips underwent MR imaging with a T1-weighted spin-echo sequence, followed by MR imaging under continuous leg traction after intravenous injection of gadolinium-DTPA. Joint fluid enhancement and labral contour detection were evaluated. Eleven hips had labral tears shown by conventional arthrography, arthroscopy and macroscopic surgical findings. Assessment of labral tears by MR imaging was correlated with the diagnosis based on these standard techniques. Joint fluid enhancement was obtained in all hips at 30 min after injection. Superior and inferior labral surfaces were completely delineated in 1 hip on the unenhanced MR images, and in 7 and 13 hips, respectively, on the enhanced images under traction. The enhanced images under traction depicted 9 of the 11 labral tears. Comparison between the unenhanced image and the enhanced image under traction avoided mistaking undercutting of the labrum for a tear in 4 hips. Contrast-enhanced MR imaging under traction was valuable for detecting labral tears non-invasively and without radiation. Follow-up examinations using this method in patients with acetabular dysplasia can help to clarify the natural course of labral disorders and enable better treatment planning. (orig./MG)

  15. Pulmonary CT angiography: optimization of contrast enhancement technique

    International Nuclear Information System (INIS)

    Ma Lianju; Tang Guangjian; Fu Jiazhen

    2012-01-01

    Objective: To derive and evaluate the formula of exactly calculating the contrast dosage used during pulmonary CT angiography (CTPA). Methods: Time density curves in 27 patients who underwent CTPA were collected and analyzed,the formula for calculating contrast dosage during CTPA was derived. 68 patients suspected of pulmonary embolism (PE) clinically but no PE on CTPA were divided randomly into group A, with bolus tracing technique (n=26), and group B, with small dose injection contrast test (SDCT) (n=42). The CT values of the right main pulmonary artery (RMPA), right upper pulmonary vein (RUPV), right posterior basal PA, right lower PV (RLPV) and the aorta were calculated. The total contrast dosage and the hard beam artifact in the SVC were compared between the two groups.Student's t test, Chi-square test and Mann-Whitney U test were used. Results: The ratio of the time from starting injection to enhancement peak of caudal end of SVC and the time to enhancement peak of the main pulmonary trunk was 0.65 ±0.09 (about 2/3), the formula for contrast dosage calculation was derived as (DTs/3 + STs/2) FR ml/s. The CT values of RMPA and RLPA between the two groups [(301 ±117), (329 ± 122) and (283 ±95), (277 ±98) HU respectively] were not significantly different (t=1.060, P=0.292; t=2.056, P=0.044), but the differences of CT values in the paired PA and PV between the two groups (median were 22.5, 58.0 and 170.5, 166.5 HU respectively) were significant (U=292, P=0.001 and U=325, P=0.005), contrast artifact of the SVC (grade 1-3) in group B (n=34, 7, 1 respectively) was significantly less than in group A (n=11, 10, 5 respectively, χ 2 =10.714, P=0.002), the contrast dosage injected in group A was ( 87.6 ± 7.3) ml, and in group B was (40.0 ±5.4) ml (P<0.01). Conclusion: CTPA with SDCT technique is superior to that with conventional bolus tracing technique regarding contrast dosage and contrast artifact in the SVC. (authors)

  16. Three-dimensional black-blood contrast-enhanced MRI improves detection of intraluminal thrombi in patients with acute ischaemic stroke.

    Science.gov (United States)

    Jang, Won; Kwak, Hyo Sung; Chung, Gyung Ho; Hwang, Seung Bae

    2018-03-19

    This study evaluated the utility of three-dimensional (3D), black-blood (BB), contrast-enhanced, magnetic resonance imaging (MRI) for the detection of intraluminal thrombi in acute stroke patients. Forty-seven patients with acute stroke involving the anterior circulation underwent MRI examination within 6 h of clinical onset. Cerebral angiography was used as the reference standard. In a blinded manner, two neuroradiologists interpreted the following three data sets: (1) diffusion-weighted imaging (DWI) + 3D BB contrast-enhanced MRI; (2) DWI + susceptibility weighted imaging (SWI); (3) DWI + 3D BB contrast-enhanced MRI + SWI. Of these patients, 47 had clots in the middle cerebral artery and four had clots in the anterior cerebral artery. For both observers, the area under the curve (Az) for data sets 1 and 3, which included 3D BB contrast-enhanced MRI, was significantly greater than it was for data set 2, which did not include 3D BB contrast-enhanced MR imaging (observer 1, 0.988 vs 0.904, p = 0.001; observer 2, 0.988 vs 0.894, p = 0.000). Three-dimensional BB contrast-enhanced MRI improves detection of intraluminal thrombi compared to conventional MRI methods in patients with acute ischaemic stroke. • BB contrast-enhanced MRI helps clinicians to assess the intraluminal clot • BB contrast-enhanced MRI improves detection of intraluminal thrombi • BB contrast-enhanced MRI for clot detection has a higher sensitivity.

  17. Sporadic insulinomas on volume perfusion CT: dynamic enhancement patterns and timing of optimal tumour-parenchyma contrast

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Liang; Xue, Hua-dan; Liu, Wei; Wang, Xuan; Sun, Hao; Li, Ping; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Wu, Wen-ming; Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)

    2017-08-15

    To assess enhancement patterns of sporadic insulinomas on volume perfusion CT (VPCT), and to identify timing of optimal tumour-parenchyma contrast. Consecutive patients who underwent VPCT for clinically suspected insulinomas were retrospectively identified. Patients with insulinomas confirmed by surgery were included, and patients with familial syndromes were excluded. Two radiologists evaluated VPCT images in consensus. Tumour-parenchyma contrast at each time point was measured, and timing of optimal contrast was determined. Time duration of hyperenhancement (tumour-parenchyma contrast >20 Hounsfield units, HU) was recorded. Perfusion parameters were evaluated. Three dynamic enhancement patterns were observed in 63 tumours: persistent hyperenhancement (hyperenhancement time window ≥10 s) in 39 (61.9%), transient hyperenhancement (hyperenhancement <10 s) in 19 (30.2%) and non-hyperenhancement in 5 (7.9%). Timing of optimal contrast was 9 s after abdominal aorta threshold (AAT) of 200 HU, with tumour-parenchyma contrast of 77.6 ± 57.2 HU. At 9 s after AAT, 14 (22.2%) tumours were non-hyperenhancing, nine of which had missed transient hyperenhancement. Insulinomas with transient and persistent hyperenhancement patterns had significantly increased perfusion. Insulinomas have variable enhancement patterns. Tumour-parenchyma contrast is time-dependent. Optimal timing of enhancement is 9 s after AAT. VPCT enables tumour detection even if the hyperenhancement is transient. (orig.)

  18. Contrast enhanced ultrasound in liver imaging

    International Nuclear Information System (INIS)

    Nielsen, Michael Bachmann; Bang, Nanna

    2004-01-01

    Ultrasound contrast agents were originally introduced to enhance the Doppler signals when detecting vessels with low velocity flow or when imaging conditions were sub-optimal. Contrast agents showed additional properties, it was discovered that a parenchymal enhancement phase in the liver followed the enhancement of the blood pool. Contrast agents have made ultrasound scanning more accurate in detection and characterization of focal hepatic lesions and the sensitivity is now comparable with CT and MRI scanning. Further, analysis of the transit time of contrast agent through the liver seems to give information on possible hepatic involvement, not only from focal lesions but also from diffuse benign parenchymal disease. The first ultrasound contrast agents were easily destroyed by the energy from the sound waves but newer agents have proved to last for longer time and hereby enable real-time scanning and make contrast enhancement suitable for interventional procedures such as biopsies and tissue ablation. Also, in monitoring the effect of tumour treatment contrast agents have been useful. A brief overview is given on some possible applications and on different techniques using ultrasound contrast agents in liver imaging. At present, the use of an ultrasound contrast agent that allows real-time scanning with low mechanical index is to be preferred

  19. Clinical significance of nerve root enhancement in contrast-enhanced MR imaging of the postoperative lumbar spine

    International Nuclear Information System (INIS)

    Lee, Yeon Soo; Lee, Eun Ja; Kang, Si Won; Choi, Eun Seok; Song, Chang June; Kim, Jong Chul

    2001-01-01

    To determine the significance of nerve root contrast enhancement in patients with residual or recurrent symptomatic postoperative lumbar spine. Eighty-eight patients with 116 postoperative lumbar disc lesions causing radiating back pain underwent enhanced MR imaging. Intradural nerve root enhancement was quantified by pixel measurement, and affected nerve roots were compared before and after contrast administration. Extradural nerve root enhancement was assessed visually, and nerve root enhancement and clinical symptoms were correlated. Associated lesions such as recurrent disc herniation, scar tissue, nerve root thickening and nerve root displacement were also evaluated. Of 26 cases (22.4%) involving intradural nerve root enhancement, 22 (84.6%) showed significant clinical symptoms (p=0.002). and of 59 (50.9%) demonstrating extradural enhancement, clinical symptoms showed significant correlation in 47 (79.7%) (p=0.001). Nerve root enhancement, including eleven cases where this was both intra-and extradural, showed highly significant association with clinical symptoms in 74 of the 116 cases (63.8%) (p=0.000). Among 33 cases (28.4%) of recurrent disc herniation, nerve root enhancement was observed in 28 (84.8%) and in 24 of these 28 (85.7%), significant correlation with clinical symptoms was observed (p=0.000). Where epidural fibrosis was present, correlation between nerve root enhancement and clinical symptoms was not significant (p>0.05). Nerve root thickening and displaced nerve root were, however, significantly associated with symptoms (87.2% and 88.6%, respectively). In patients with postoperative lumbar spine, the association between nerve root enhancement revealed by MRI and clinical symptoms was highly significant

  20. Evaluation of dynamic contrast-enhanced T1-weighted perfusion MRI in the differentiation of tumor recurrence from radiation necrosis

    DEFF Research Database (Denmark)

    Larsen, Anne Vibeke Andrée; Simonsen, Helle J; Law, Ian

    2013-01-01

    INTRODUCTION: To investigate if perfusion measured with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can be used to differentiate radiation necrosis from tumor recurrence in patients with high-grade glioma. METHODS: The study was approved by the institutional review board...... to measure cerebral blood volume (CBV), blood-brain barrier (BBB) permeability and cerebral blood flow (CBF). Subjects also underwent FDG-PET and lesions were classified as either metabolically active or inactive. Follow-up clinical MRI and lesion histology in case of additional tissue resection was used...... to determine whether lesions were regressing or progressing. RESULTS: Fourteen enhancing lesions could be classified as progressing (11) or regressing (three). An empirical threshold of 2.0 ml/100 g for CBV allowed detection of regressing lesions with a sensitivity of 100 % and specificity of 100 %. FDG-PET...

  1. Contrast-enhanced MR angiography in Leriche's syndrome

    International Nuclear Information System (INIS)

    Link, J.; Steffens, J.C.; Brossmann, J.; Heller, M.; Loose, R.

    1998-01-01

    Purpose: To determine the usefulness of contrast-enhanced MR angiography for the diagnosis of Leriche's syndrome. Material and methods: Leriche's syndrome was seen in 7 patients via DSA. In [dition, contrast-enhanced MR angiography was performed (T R 7.8 ms/T E 2.1 ms, flip angle 30 , slab thickness 116 mm, slice thickness 1.82 mm, 64 partitions, FOV 500x438 mm, matrix 224x512). Results: Diagnosis of Leriche's syndrome was possible by contrast-enhanced MR angiography in each case. Visualisation of the femoral arteries was not possible in two patients by intraarterial DSA, in three other patients there was an insufficient contrast in the femoral arteries with DSA. Contrast-enhanced MR angiography revealed good visualisation of the femoral arteries in these patients. In [dition, contrast-enhanced MR angiography allowed complete visualisation of the patent lower limb arteries. In intraarterial DSA visualisation of the lower limb arteries was achieved reached in only one patient, but was incomplete. Conclusion: Contrast-enhanced MR angiography yielded the correct diagnosis of Leriche's syndrome in all 7 patients. Contrast-enhanced MR angiography was superior to DSA in the assessment of the distal run-off vessels in five of seven patients. (orig.) [de

  2. Evaluation of residual hepatocellular carcinoma after transcatheter arterial chemoembolization: Comparison between contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography

    International Nuclear Information System (INIS)

    Kim, Seung Hoon; Lim, Hyo Keun; Lee, Won Jae

    2001-01-01

    To evaluate the effectiveness of contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography (PDUS) in assessing the therapeutic effect of transcatheter arterial chemoembolization (TACE) in hepatocellular carcinomas (HCCs). The follow-up contrast-enhanced helical CT and contrast-enhanced PDUS were performed for twenty-nine nodular HCCs from twelve patients previously treated with TACE. We defined the residual HCCs as intratumoral enhancing area on contrast-enhanced helical CT and color signal on contrast-enhanced PDUS. The interval between two examinations was less than 2 weeks (mean, 9 days). Two radiologists evaluated two examinations by consensus, and the results of these two examination were compared with the findings of other examinations including CT, angiography, and/or pathology to calculate the sensitivity, specificity and accuracy of two examinations. Of the 29 HCCs, 20 had residual HCCs whereas no residual HCCs in 9 HCCs on pathologic examination and/or follow-up radiologic study. The sensitivity, sensitivity and accuracy of contrast-enhanced helical CT were 65 (13/20), 89 (8/9), and 72% (21/29) while those of contrast-enhanced PDUS were 100 (20/20), 89 (8/9) and 97% (28/29), respectively. A microbubble contrast-enhanced PDUS was more effective in the detection of residual tumor in HCCs following TACE than contrast-enhanced helical CT.

  3. Change in contrast enhancement of HCC on 1-month follow-up CT after local radiotherapy: An early predictor of final treatment response

    International Nuclear Information System (INIS)

    Kim, Eun Young; Choi, Dongil; Lim, Do Hoon; Lee, Won Jae; Yoo, Byung Chul; Paik, Seung Woon

    2009-01-01

    Background: The purpose of this study was to evaluate the change in contrast enhancement of HCC on 1-month follow-up CT after local radiotherapy (RT) as an early predictor of final treatment response. Materials: Fifty patients who underwent local RT for HCCs had both pre-RT and post-RT CT scans including 1-month follow-up CT. We assessed the final treatment response by using the change in maximal tumor size on 6-12-month follow-up CT scan after RT. We also evaluated the change in tumor enhancement between pre-RT and 1-month follow-up CT scans. Results: A final treatment response was achieved in 27 (54%) of 50 patients, who showed either a complete response (n = 11) or a partial response (n = 16). Compared with non-responsive patients (n = 23), responsive patients showed a significant decrease in tumor enhancement on 1-month follow-up CT after RT in both objective and subjective analyses (each P < 0.001). Conclusion: The change in contrast enhancement of HCC seen on the 1-month follow-up CT in patients after local RT may be used as an early predictor of final treatment response.

  4. Contrast-enhanced MR imaging of the breast in patients with breast implants after cancer surgery

    International Nuclear Information System (INIS)

    Bone, B.; Aspelin, P.; Isberg, B.; Perbeck, L.; Veress, B.

    1995-01-01

    The purpose of the study was to determine the value of contrast-enhanced MR imaging in the assessment of local recurrence in breast cancer patients who underwent mastectomy and breast reconstruction with an implant. Eighty-three patients have been evaluated by semidynamic contrast-enhanced MR imaging. The T1-weighted FLASH 3-D sequence was repeated twice postcontrast for evaluation of the entire breast bilaterally. The findings were compared to physical examination, mammography and histopathology. Recurrence verified by histopathology occurred in 14 of 83 patients (17%). Contrast-enhanced MR imaging was superior to palpation and mammography in revealing recurrences, especially when these were located close to the chest wall. MR was also more sensitive in detecting multiple foci of cancers. Our study revealed that MR imaging was influenced by size, type and composition of the tumor, as illustrated by the false-negative results. Therefore, the use of all 3 investigation methods is necessary for detecting recurrence at an early stage during the postoperative follow-up. (orig.)

  5. Dynamic Contrast-Enhanced MRI of Cervical Cancers: Temporal Percentile Screening of Contrast Enhancement Identifies Parameters for Prediction of Chemoradioresistance

    International Nuclear Information System (INIS)

    Andersen, Erlend K.F.; Hole, Knut Håkon; Lund, Kjersti V.; Sundfør, Kolbein; Kristensen, Gunnar B.; Lyng, Heidi; Malinen, Eirik

    2012-01-01

    Purpose: To systematically screen the tumor contrast enhancement of locally advanced cervical cancers to assess the prognostic value of two descriptive parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Methods and Materials: This study included a prospectively collected cohort of 81 patients who underwent DCE-MRI with gadopentetate dimeglumine before chemoradiotherapy. The following descriptive DCE-MRI parameters were extracted voxel by voxel and presented as histograms for each time point in the dynamic series: normalized relative signal increase (nRSI) and normalized area under the curve (nAUC). The first to 100th percentiles of the histograms were included in a log-rank survival test, resulting in p value and relative risk maps of all percentile–time intervals for each DCE-MRI parameter. The maps were used to evaluate the robustness of the individual percentile–time pairs and to construct prognostic parameters. Clinical endpoints were locoregional control and progression-free survival. The study was approved by the institutional ethics committee. Results: The p value maps of nRSI and nAUC showed a large continuous region of percentile–time pairs that were significantly associated with locoregional control (p < 0.05). These parameters had prognostic impact independent of tumor stage, volume, and lymph node status on multivariate analysis. Only a small percentile–time interval of nRSI was associated with progression-free survival. Conclusions: The percentile–time screening identified DCE-MRI parameters that predict long-term locoregional control after chemoradiotherapy of cervical cancer.

  6. Prognostic value of contrast-enhanced MR mammography in patients with breast cancer

    International Nuclear Information System (INIS)

    Fischer, U.; Kopka, L.; Brinck, U.; Korabiowska, M.; Schauer, A.; Grabbe, E.

    1997-01-01

    The objective of this study was to evaluate the prognostic value of contrast-enhanced MR mammography in patients with breast cancer. A total of 190 patients with breast cancer (37 noninvasive carcinomas, 153 invasive carcinomas) underwent dynamic contrast-enhanced MR mammography preoperatively. Using 1.5-T unit, T1-weighted sequences (2D FLASH) were obtained repeatedly one time before and five times after IV administration of 0.1 mmol gadopentetate-dimeglumine per kilogram body weight. The findings on MR imaging were correlated with histopathologically defined prognostic factors (histological type, tumor size, tumor grading, metastasis in lymph nodes). In addition, immunohistochemically defined prognostic factors (c-erbB-1,c-erbB-2, p53, Ki-67) were correlated with the signal increase on MR mammogram in 40 patients. There was no significant correlation between the findings on MR mammography and the histopathological type of carcinoma, the grading, and the lymphonodular status. Noninvasive carcinomas showed a higher rate of moderate (38 %) or low (27 %) enhancement on MR imaging than invasive carcinomas (6 and 3 %). The results on MR mammography and the results of immunohistochemical stainings did not correlate significantly. Noninvasive carcinomas showed significantly lower enhancement than invasive carcinomas. However, the signal behavior of contrast-enhanced MR mammography is not related to established histopathological prognostic parameters as subtyping, grading, nodal status, and the expression of certain oncogenes/tumor suppressor genes. (orig.). With 5 tabs

  7. Diagnostic accuracy of magnetic resonance, computed tomography and contrast enhanced ultrasound in radiological multimodality assessment of peribiliary liver metastases.

    Directory of Open Access Journals (Sweden)

    Vincenza Granata

    Full Text Available We compared diagnostic performance of Magnetic Resonance (MR, Computed Tomography (CT and Ultrasound (US with (CEUS and without contrast medium to identify peribiliary metastasis.We identified 35 subjects with histological proven peribiliary metastases who underwent CEUS, CT and MR study. Four radiologists evaluated the presence of peribiliary lesions, using a 4-point confidence scale. Echogenicity, density and T1-Weigthed (T1-W, T2-W and Diffusion Weighted Imaging (DWI signal intensity as well as the enhancement pattern during contrast studies on CEUS, CT and MR so as hepatobiliary-phase on MRI was assessed.All lesions were detected by MR. CT detected 8 lesions, while US/CEUS detected one lesion. According to the site of the lesion, respect to the bile duct and hepatic parenchyma: 19 (54.3% were periductal, 15 (42.8% were intra-periductal and 1 (2.8% was periductal-intrahepatic. According to the confidence scale MRI had the best diagnostic performance to assess the lesion. CT obtained lower diagnostic performance. There was no significant difference in MR signal intensity and contrast enhancement among all metastases (p>0.05. There was no significant difference in CT density and contrast enhancement among all metastases (p>0.05.MRI is the method of choice for biliary tract tumors but it does not allow a correct differential diagnosis among different histological types of metastasis. The presence of biliary tree dilatation without hepatic lesions on CT and US/CEUS study may be an indirect sign of peribiliary metastases and for this reason the patient should be evaluated by MRI.

  8. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    International Nuclear Information System (INIS)

    Kim, You Sung; Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun; Lee, Soo Rim; Hwang, Seong Su; Lim, Yeon Soo; Park, Jeong Mi

    2017-01-01

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT

  9. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Sung [Dept. of Radiology, Ilsan Paik Hospital, College of Medicine, Inje University, Goyang (Korea, Republic of); Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Lee, Soo Rim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of); Hwang, Seong Su [Dept. of Radiology, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of); Lim, Yeon Soo [Dept. of Radiology, Bucheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Bucheon (Korea, Republic of); Park, Jeong Mi [Dept. of Radiology, Yeouido St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-02-15

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT.

  10. Primary pulmonary low-grade angiosarcoma characterized by mismatch between {sup 18}F-FDG FET and dynamic contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Eun Young; Lee, Ho Yun; Han, Joung Ho; Choi, Joon Young [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-10-15

    We report a rare case of primary pulmonary low-grade angiosarcoma on dynamic contrast-enhanced CT and {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT imaging. A 38-year-old, asymptomatic woman was hospitalized because of an abnormality on chest radiography. A dynamic contrast-enhanced chest CT showed a 1.2 cm-sized irregular-margined nodule with strong and persistent enhancement in the right lower lobe. The lesion had low metabolic activity on an {sup 18}F-FDG PET/CT scan. The patient underwent a wedge resection for the lesion, and pathology revealed a primary pulmonary low-grade angiosarcoma.

  11. Enhancing contrast of magnetic resonance imaging in patients with ...

    African Journals Online (AJOL)

    DTPA), a recent magnetic resonance imaging (MRI) contrast agent, in hepatobiliary system of patients with liver cirrhosis. Methods: Liver cirrhosis patients that underwent contrast MRI examination at Renai Hospital, Taipei City, Taiwan were ...

  12. Assessment of the link between quantitative biexponential diffusion-weighted imaging and contrast-enhanced MRI in the liver

    NARCIS (Netherlands)

    Dijkstra, Hildebrand; Oudkerk, Matthijs; Kappert, Peter; Sijens, Paul E.

    Purpose: To investigate if intravoxel incoherent motion (IVIM) modeled diffusion-weighted imaging (DWI) can be linked to contrast-enhanced (CE-)MRI in liver parenchyma and liver lesions. Methods: Twenty-five patients underwent IVIM-DWI followed by multiphase CE-MRI using Gd-EOB-DTPA (n = 20) or

  13. Examination of hepatic contrast-enhanced CT monitored by Smart Prep

    International Nuclear Information System (INIS)

    Kakizaki, Dai; Saito, Kazuhiro; Sakurada, Toru; Abe, Kimihiko; Suzuki, Kenji

    1999-01-01

    The aim of the present study is to obtain the time density curves of the contrast-enhanced CT of hepatic portal vein, hepatic and splenic parenchyma, and to examine the relation with age, body weight, type of liver dysfunction. Subjects were 32 patients with liver tumors or liver diseases. For this purpose, the procedure of hepatic CT was monitored by Smart Prep and the images of whole liver was taken when the level of the contrast at the hepatic portal vein reached to the enhancement threshold. The contrast medium used was Iomeprol 300. The adverse reactions by Iomeprol 300 were mild and any treatment did not need. There was no correlation age and weight with enhancement threshold at the hepatic portal vein and peak time at the splenic parenchyma. The enhancement threshold at the hepatic portal vein was various in patients with chrrhosis and chronic hepatitis, and tended to be delayed in patients with chrrhosis. The peak time of the splenic parenchyma was up to 52 seconds in all patients with chronic hepatitis. The shortage of the enhancement threshold and the increase in blood flow at arterial early phase were observed in the patients with advanced acute hepatitis. This method should be examined more cases with various hepatic diseases. (K.H.)

  14. Technical innovation in dynamic contrast-enhanced magnetic resonance imaging of musculoskeletal tumors: an MR angiographic sequence using a sparse k-space sampling strategy

    International Nuclear Information System (INIS)

    Fayad, Laura M.; Mugera, Charles; Grande, Filippo del; Soldatos, Theodoros; Flammang, Aaron

    2013-01-01

    We demonstrate the clinical use of an MR angiography sequence performed with sparse k-space sampling (MRA), as a method for dynamic contrast-enhanced (DCE)-MRI, and apply it to the assessment of sarcomas for treatment response. Three subjects with sarcomas (2 with osteosarcoma, 1 with high-grade soft tissue sarcomas) underwent MRI after neoadjuvant therapy/prior to surgery, with conventional MRI (T1-weighted, fluid-sensitive, static post-contrast T1-weighted sequences) and DCE-MRI (MRA, time resolution = 7-10 s, TR/TE 2.4/0.9 ms, FOV 40 cm 2 ). Images were reviewed by two observers in consensus who recorded image quality (1 = diagnostic, no significant artifacts, 2 = diagnostic, 75 % with good response, >75 % with poor response). DCE-MRI findings were concordant with histological response (arterial enhancement with poor response, no arterial enhancement with good response). Unlike conventional DCE-MRI sequences, an MRA sequence with sparse k-space sampling is easily integrated into a routine musculoskeletal tumor MRI protocol, with high diagnostic quality. In this preliminary work, tumor enhancement characteristics by DCE-MRI were used to assess treatment response. (orig.)

  15. Assessment of arterial hypervascularity of hepatocellular carcinoma: comparison of contrast-enhanced US and gadoxetate disodium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Sugimoto, Katsutoshi; Moriyasu, Fuminori; Taira, Junichi; Imai, Yasuharu; Shiraishi, Junji; Saito, Kazuhiro; Saguchi, Toru

    2012-01-01

    To compare contrast-enhanced (CE) ultrasound with gadoxetate disodium-enhanced magnetic resonance (MR) imaging in the assessment of arterial hypervascularity of hepatocellular carcinoma (HCC) and dysplastic nodule (DN), with CT during hepatic arteriography (CTHA) as the reference standard. This study included 54 consecutively diagnosed patients, with 57 histologically confirmed HCCs and 3 DNs (high-grade). All patients underwent CE ultrasound, gadoxetate disodium-enhanced MR imaging and CTHA. Two trained diagnostic radiologists interpreted the CTHA images and rated the degree of intratumoral arterial vascularity by consensus using a five-point confidence scale as the reference standard. In the observer study, the degrees of vascularity on CE ultrasound and gadoxetate disodium-enhanced MR images were qualitatively analysed by four independent readers using a five-point confidence scale. Diagnostic accuracy was analysed by receiver-operating characteristic (ROC) analysis. The diagnostic accuracies of the average area under the ROC curve (AUC) were significantly greater with CE ultrasound (average AUC: 0.94; 95% confidence interval [CI]: 0.88-1.00) than with gadoxetate disodium-enhanced MR imaging (average AUC 0.84, 95% CI 0.74-0.93, P = 0.0014). Contrast-enhanced ultrasound yields a significantly higher AUC value than gadoxetate disodium-enhanced MR imaging in the assessment of arterial hypervascularity of HCC and DN. Key Points circle Arterial hypervascularity is an important feature determining treatment options in hepatocellular carcinoma. circle It can be assessed by contrast-enhanced (CE) ultrasound or magnetic resonance (MR) imaging. circle CE ultrasound was more accurate than Gd-EOB-DTPA MRI in assessing intratumoral vascularity. circle Hypovascular hepatic nodules should be further investigated using CE ultrasound. (orig.)

  16. Contrast-enhanced ultrasonography for the determination of Crohn’s disease activity – preliminary experience

    Science.gov (United States)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Kłopocka, Maria; Liebert, Ariel; Lemanowicz, Adam; Serafin, Zbigniew

    2014-01-01

    Summary Background Contrast-enhanced ultrasound (CEUS) is a recent non-invasive modality, which may partially replace currently used techniques (endoscopy, CT enterography and MR enterography) in the diagnostics and assessment of Crohn’s disease (CD). The aim of the study was to analyze early experience in the use of CEUS for the measurement of activity and staging of CD. Material/Methods Eleven patients previously diagnosed with CD were included in the study. They underwent contrast-enhanced ultrasonography (SonoVue, Bracco), low-dose CT enterography (LDCTE), assessment of laboratory markers of inflammation and clinical CD activity index (CDAI). Contrast enhancement was evaluated using a semi-quantitative method and a quantitative method that included measurement of peak enhancement (PE), enhancement curve rise time (RT) and wash-in-rate (WiR). Results Ileal wall thickening was observed in all patients. Semi-quantitative method was used to observe CD activity in CEUS in 10 cases that perfectly matched LDCTE findings. There was a moderate positive correlation between PE and CDAI (r=0.65, p<0.001). There was no significant relationship between perfusion parameters and laboratory markers of inflammation. Conclusions CEUS is a promising modality for non-invasive assessment of pathologic ileal vascularization in the course of Crohn’s disease. Intensity of enhancement in CEUS reflects activity of the disease detected in LDCTE and correlates with CDAI. PMID:24723988

  17. Contrast-enhanced ultrasonography for the determination of Crohn’s disease activity – preliminary experience

    International Nuclear Information System (INIS)

    Białecki, Marcin; Białecka, Agnieszka; Laskowska, Katarzyna; Kłopocka, Maria; Liebert, Ariel; Lemanowicz, Adam; Serafin, Zbigniew

    2014-01-01

    Contrast-enhanced ultrasound (CEUS) is a recent non-invasive modality, which may partially replace currently used techniques (endoscopy, CT enterography and MR enterography) in the diagnostics and assessment of Crohn’s disease (CD). The aim of the study was to analyze early experience in the use of CEUS for the measurement of activity and staging of CD. Eleven patients previously diagnosed with CD were included in the study. They underwent contrast-enhanced ultrasonography (SonoVue, Bracco), low-dose CT enterography (LDCTE), assessment of laboratory markers of inflammation and clinical CD activity index (CDAI). Contrast enhancement was evaluated using a semi-quantitative method and a quantitative method that included measurement of peak enhancement (PE), enhancement curve rise time (RT) and wash-in-rate (WiR). Ileal wall thickening was observed in all patients. Semi-quantitative method was used to observe CD activity in CEUS in 10 cases that perfectly matched LDCTE findings. There was a moderate positive correlation between PE and CDAI (r=0.65, p<0.001). There was no significant relationship between perfusion parameters and laboratory markers of inflammation. CEUS is a promising modality for non-invasive assessment of pathologic ileal vascularization in the course of Crohn’s disease. Intensity of enhancement in CEUS reflects activity of the disease detected in LDCTE and correlates with CDAI

  18. Hepatocellular carcinoma on MR diffusion weighted imaging and dynamic contrast-enhanced imaging

    International Nuclear Information System (INIS)

    Dong Aisheng; Zuo Changjing; Tian Jianming; Lu Jianping; Wang Jian; Wang Li; Wang Fei

    2009-01-01

    Objective: To evaluate the findings of hepatocellular carcinoma (HCC) on DWI and dynamic Gd-DTPA-enhanced MR imaging. Methods: Eighty one patients with chronic hepatitis or liver cirrhosis underwent both DWI and dynamic Gd-DTPA-enhanced MRI studies of the liver for HCC detection. MR data of were retrospectively analyzed. Two observers determined in consensus the location and the number of focal lesions. The signal manifestation of the lesions on DWI and dynamic Gd-DTPA-enhanced MR imaging were analyzed. Results: DWI and Gd-DTPA-enhanced MR images detected 122 HCCs and 14 benign lesions. One hundred and sixteen HCCs (95.1%) showed hyperintensity on DWI and 6 HCCs in patients with severe cirrhosis showed isointensity. One hundred and five HCCs (86.1%) revealed hypointensity, 11 HCCs (9.0%) showed isointensity and 6 HCCs (4.9%) exhibited hyperintensity on T 1 weighted images. On Gd-DTPA-enhanced MR images, 101 HCCs(82.8%) were significantly enhanced on arterial phase and 99 HCCs showed hypointensity on portal and equilibrium phases. Twenty HCCs (16.4%), 18 of 20 less than 20 mm in diameter, showed isointensity on arterial phase and hyperintensity on DWI. Eight of 14 benign lesions showed hyperintensity and 6 isointensity on DWI. Five benign lesions with hypointensity on T 1 weighted images without contrast and hyperintensity on DWI showed no enhancement on Gd-DTPA-enhanced MR images; 6 benign lesions with isointensity on both T 1 weighted imaging without contrast and DWI exhibited avid enhancement on arterial phase and isointensty on portal and equilibrium phases; one of the two benign lesions, with isointensity before and after contrast images and hyperintentiy on DWI, was a regenerative nodule; another regenerative nodule with hyperintensity on both T 1 weighted images without contrast and DWI was greatly enhanced on arterial phase and showed isointensity on portal and equilibrium phases. Conclusions: Most of the HCCs were greatly enhanced on arterial phase on Gd-DTPA-enhanced

  19. Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Xu Huixiong; Chen Lida; Xie Xiaoyan; Xie Xiaohua; Xu Zuofeng; Liu Guangjian; Lin Manxia; Wang Zhu; Lu Mingde

    2010-01-01

    Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ultrasound, 89.5% (17/19) for CEUS, and 78.9% (15/19) for CECT (all P > 0.05 between every two groups). CEUS significantly improved the lesion conspicuity in comparison with CECT. CEUS and CECT made correct diagnoses in 30 (93.8%) and 25 (78.1%) lesions prior to pathological examination (P = 0.125). Conclusion: The enhancement pattern of hilar cholangiocarcinoma on CEUS was similar with that on CECT in arterial phase, whereas in portal phase hilar cholangiocarcinoma shows hypoenhancement more likely on CEUS. CEUS and CECT lead to similar results in evaluating portal vein infiltration and diagnosis of this entity.

  20. Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Xu Huixiong, E-mail: xuhuixiong@hotmail.co [Department of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China); Chen Lida; Xie Xiaoyan; Xie Xiaohua; Xu Zuofeng; Liu Guangjian; Lin Manxia; Wang Zhu [Department of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China); Lu Mingde, E-mail: lumd@21cn.co [Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China)

    2010-08-15

    Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ultrasound, 89.5% (17/19) for CEUS, and 78.9% (15/19) for CECT (all P > 0.05 between every two groups). CEUS significantly improved the lesion conspicuity in comparison with CECT. CEUS and CECT made correct diagnoses in 30 (93.8%) and 25 (78.1%) lesions prior to pathological examination (P = 0.125). Conclusion: The enhancement pattern of hilar cholangiocarcinoma on CEUS was similar with that on CECT in arterial phase, whereas in portal phase hilar cholangiocarcinoma shows hypoenhancement more likely on CEUS. CEUS and CECT lead to similar results in evaluating portal vein infiltration and diagnosis of this entity.

  1. Angiogenesis and dynamic contrast enhanced MRI of benign and malignant breast lesions: preliminary results

    International Nuclear Information System (INIS)

    Liu Peifang; Bao Runxian; Niu Yun; Yu Yong

    2002-01-01

    Objective: To determine whether dynamic contrast enhanced MRI features of early-phase enhancement rate, enhancement amplitude, and signal intensity (SI) time course are associated with the microvessel density (MVD) and vascular endothelial growth factor (VEGF) expression of malignant and benign breast lesions. Methods: Thirty-eight patients with histopathologically verified breast lesions underwent dynamic contrast enhanced MRI. SI changes during dynamic scanning were assessed quantitatively. Early-phase enhancement rate and enhancement amplitude were calculated. Time-SI curves of the lesions were obtained and classified according to their shapes as type I (which was steady enhancement to the end of the dynamic data acquisition at 7.5 min), type II (plateau of SI after avid initial contrast enhancement), or type III (washout of SI after avid initial contrast enhancement). the mean MVD and VEGF expression of the lesions were measured with immuno-histochemical staining method in all the histologic specimens by pathologists without the knowledge of the results of the MR examination. The relationships among dynamic contrast enhanced MRI features, MVD, and VEGF expression of benign and malignant breast lesions were analyzed. Results: Histology revealed 21 malignancies and 17 benign lesions. The mean MVD and VEGF expression for 21 malignant lesions were statistically higher than the mean MVD and VEGF expression for 17 benign lesions. High VEGF expression of benign and malignant breast lesions showed an association with increased MVD. Among all 38 lesions, greater (> 60%) MR early-phase enhancement rate and time-SI curve type II and III showed an association with increased MVD and higher VEGF expression level. All the differences mentioned above showed statistical significance except that the difference between VEGF expression and the distribution of curve types had no statistical significance. No significant relationships were observed between the mean of enhancement

  2. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncica, Ana Maria; Saftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...

  3. Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml

    International Nuclear Information System (INIS)

    Behrendt, F.F.; Mahnken, A.H.; Keil, S.; Das, M.; Hohl, C.; Guenther, R.W.; Muehlenbruch, G.; Bauer, D.; Seidensticker, P.; Jost, E.; Wildberger, J.E.

    2008-01-01

    The purpose of this study was to intraindividually evaluate the difference in intraluminal vessel and parenchyma contrast enhancement of two different iodine concentrations in multidetector-row computed tomography (MDCT) of the abdomen. Eighty-three patients underwent baseline and follow-up MDCT-scanning (Somatom Sensation 16; Siemens, Forchheim, Germany) of the abdomen using contrast media containing 370 mg iodine/ml (protocol A; Ultravist 370, Bayer Schering Pharma, Berlin, Germany) and 300 mg iodine/ml (protocol B; Ultravist 300). The total iodine load (37 g iodine) and the iodine delivery rate (1.29 g iodine/s) were identical for both protocols. Contrast enhancement in the portal venous phase was measured in the abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney. Mean attenuation values were compared using paired t-test. Intraindividual comparison revealed no statistically significant differences of the mean attenuation values between protocols A and B for all anatomic sites: abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney (all P > 0.05). Given an injection protocol with constant total iodine load and constant iodine delivery rate, the iodine concentration of contrast media does not significantly influence abdominal contrast enhancement in the portal venous phase. (orig.)

  4. Dynamic contrast-enhanced MR of the prostatic cancer and benign prostatic hyperplasia: correlation with angiogenesis

    International Nuclear Information System (INIS)

    Ni Xinchu; Shen Junkang; Lu Zhian; Zhou Lijuan; Yang Xiaochun; Wang Guanzhong; Zhang Caiyuan; Wang Shuizhen; Qian Minghui; Chan Yuxi; Qian Nong; Xiang Jianpo; Pan Changjie; Rong Weiliang; Chen Jianguo

    2005-01-01

    Objective: To evaluate the role of dynamic contrast-enhanced magnetic resonance imaging (MRI) in the diagnose of prostatic cancer and benign prostatic hyperplasia (BPH), and to determine the correlation between dynamic MRI findings with angiogenesis. Methods: Thirty-two cases of prostatic cancer and 40 cases of BPH underwent dynamic contrast-enhanced MRI. All the patients in this study were diagnosed by histopathology. The results of dynamic contrast-enhanced MRI were evaluated by early-phase enhancement parameters and time-signal intensity curves (SI-T curves), and the curves were classified according to their shapes as type I, which had steady enhancement; type II, plateau of signal intensity; and type III, washout of signal intensity. The pathologic specimens of region of interest (ROI ) were obtained, and HE staining, immunohistochemical vascular endothelial growth factor (VEGF), and microvessel density (MVD) measurements were performed. The relationships among dynamic contrast-enhanced MRI features, VEGF, and MVD expression were analyzed. Results: In the early-phase enhancement parameters of dynamic contrast-enhanced MRI, onset time, maximum signal intensity, and early-phase enhancement rate differed between prostatic cancer and BPH (P<0.01, 0.05, 0.01), but there were some overlaps between them. The intermediate and late post-contrast periods were characterized with the lesion SI-T curves. The SI-T curve of prostatic cancer was mainly type III (21 cases). Type II could be seen in both prostatic cancer (8 cases) and BPH (19 cases). Type I most appeared in BPH (18 cases). The distributions proved to have significant difference (P<0.001). The mean VEGF and MVD level of 32 prostatic cancer patients were significantly higher than those of 40 BPH patients (P<0.001). MVD level of prostatic cancer and BPH showed an association with VEGF level (P<0.01). The maximum signal intensity and early-phase enhancement rate in both prostatic cancer and BPH showed an association

  5. Contrast enhancement CT by iopamidol

    International Nuclear Information System (INIS)

    Mori, Masaki; Makita, Nobue; Yanai, Kyoko

    1984-01-01

    In order to evaluate the contrast enhancement effect and safety of iopamidol (IOP) in CT examination, IOP was compared with angiographin (AG). In the liver and abdominal aorta, peak CT values were obtained earlier and were higher in the group with AG than in the group with IOP. However, CT values in the group with IOP decreased a little more slowly than those in the group with AG. There was no significant difference in the effect on contrast enhancement between the groups. Intravenous injection of IOP caused lower degree of burning sensation than that of AG, and some of the patients with IOP did not feel burning sensation at all. Changes in clinical laboratory values were slight before and after intravenous injection of IOP. These results suggest that IOP is satisfactory in terms of safety and effect on contrast enhancement in CT examination. (Namekawa, K.)

  6. Three-dimensional contrast-enhanced MRI using an intravascular contrast agent for detection of traumatic intra-abdominal hemorrhage and abdominal parenchymal injuries: an experimental study

    International Nuclear Information System (INIS)

    Weishaupt, D.; Ruehm, S.G.; Patak, M.A.; Schmidt, M.; Debatin, J.F.; Hetzer, F.H.

    2000-01-01

    The aim of this study was to compare the performance of 3D MRI in conjunction with an intravascular contrast agent to spiral contrast-enhanced CT, regarding the detection of abdominal parenchymal injuries as well as peritoneal hemorrhage in an animal model. Liver and kidney injuries were created surgically in six female pigs under general anesthesia. All pigs underwent contrast-enhanced spiral CT and 3D MR imaging following administration of an intravascular contrast agent (NC100150 Injection). Two readers rated their confidence independently on MR and CT data sets using a five-point scale for the presence of organ injury and hemoperitoneum. Autopsy findings served as standard of reference. Sensitivity and specificity for MR in detecting hepatic and renal injuries as well as hemoperitoneum was 100 %. Computed tomography was less accurate with sensitivity and specificity values of 90 and 94 %, respectively. Receiver operating characteristics (ROC) analysis revealed a higher confidence when interpretation was based on MR images. In an animal model 3D MR imaging in conjunction with an intravascular contrast agent proved highly accurate in detecting and localizing parenchymal injuries to the upper abdomen as well as in detecting intraperitoneal blood collections. (orig.)

  7. Real-time 3-dimensional contrast-enhanced ultrasound in detecting hemorrhage of blunt renal trauma.

    Science.gov (United States)

    Xu, Rui-Xue; Li, Ye-Kuo; Li, Ting; Wang, Sha-Sha; Yuan, Gui-Zhong; Zhou, Qun-Fang; Zheng, Hai-Rong; Yan, Fei

    2013-10-01

    The objective of this study is to evaluate the diagnostic value of real-time 3-dimensional contrast-enhanced ultrasound in the hemorrhage of blunt renal trauma. Eighteen healthy New Zealand white rabbits were randomly divided into 3 groups. Blunt renal trauma was performed on each group by using minitype striker. Ultrasonography, color Doppler flow imaging, and contrast-enhanced 2-dimensional and real-time 3-dimensional ultrasound were applied before and after the strike. The time to shock and blood pressure were subjected to statistical analysis. Then, a comparative study of ultrasound and pathology was carried out. All the struck kidneys were traumatic. In the ultrasonography, free fluid was found under the renal capsule. In the color Doppler flow imaging, active hemorrhage was not identified. In 2-dimensional contrast-enhanced ultrasound, active hemorrhage of the damaged kidney was characterized. Real-time 3-dimensional contrast-enhanced ultrasound showed a real-time and stereoscopic ongoing bleeding of the injured kidney. The wider the hemorrhage area in 4-dimensional contrast-enhanced ultrasound was, the faster the blood pressure decreased. Real-time 3-dimensional contrast-enhanced ultrasound is a promising noninvasive tool for stereoscopically and vividly detecting ongoing hemorrhage of blunt renal trauma in real time. © 2013.

  8. Preliminary study of single contrast enhanced dual energy heart imaging using dual-source CT

    International Nuclear Information System (INIS)

    Peng Jin; Zhang Longjiang; Zhou Changsheng; Lu Guangming; Ma Yan; Gu Haifeng

    2009-01-01

    Objective: To evaluate the feasibility and preliminary applications of single contrast enhanced dual energy heart imaging using dual-source CT (DSCT). Methods: Thirty patients underwent dual energy heart imaging with DSCT, of which 6 cases underwent SPECT or DSA within one week. Two experienced radiologists assessed image quality of coronary arteries and iodine map of myocardium. and correlated the coronary artery stenosis with the perfusion distribution of iodine map. Results: l00% (300/300) segments reached diagnostic standards. The mean score of image for all patients was 4.68±0.57. Mural coronary artery was present in 10 segments in S cases, atherosclerotic plaques in 32 segments in 12 cases, of which 20 segments having ≥50% stenosis, 12 segments ≤50% stenosis; dual energy CT coronary angiography was consistent with the DSA in 3 patients. 37 segmental perfusion abnormalities on iodine map were found in 15 cases, including 28 coronary blood supply segment narrow segment and 9 no coronary stenosis (including three negative segments in SPECD. Conclusion: Single contrast enhanced dual energy heart imaging can provide good coronary artery and myocardium perfusion images in the patients with appropriate heart rate, which has a potential to be used in the clinic and further studies are needed. (authors)

  9. Field strength and dose dependence of contrast enhancement by gadolinium-based MR contrast agents

    International Nuclear Information System (INIS)

    Rinck, P.A.; Muller, R.N.

    1999-01-01

    The relaxivities r 1 and r 2 of magnetic resonance contrast agents and the T 1 relaxation time values of tissues are strongly field dependent. We present quantitative data and simulations of different gadolinium-based extracellular fluid contrast agents and the modulation of their contrast enhancement by the magnetic field to be able to answer the following questions: How are the dose and field dependences of their contrast enhancement? Is there an interrelationship between dose and field dependence? Should one increase or decrease doses at specific fields? Nuclear magnetic relaxation dispersion data were acquired for the following contrast agents: gadopentetate dimeglumine, gadoterate meglumine, gadodiamide injection, and gadoteridol injection, as well as for several normal and pathological human tissue samples. The magnetic field range stretched from 0.0002 to 4.7 T, including the entire clinical imaging range. The data acquired were then fitted with the appropriate theoretical models. The combination of the diamagnetic relaxation rates (R 1 = 1/T 1 and R 2 = 1/T 2 ) of tissues with the respective paramagnetic contributions of the contrast agents allowed the prediction of image contrast at any magnetic field. The results revealed a nearly identical field and dose-dependent increase of contrast enhancement induced by these contrast agents within a certain dose range. The target tissue concentration (TTC) was an important though nonlinear factor for enhancement. The currently recommended dose of 0.1 mmol/kg body weight seems to be a compromise close to the lower limits of diagnostically sufficient contrast enhancement for clinical imaging at all field strengths. At low field contrast enhancement might be insufficient. Adjustment of dose or concentration, or a new class of contrast agents with optimized relaxivity, would be a valuable contribution to a better diagnostic yield of contrast enhancement at all fields. (orig.)

  10. Sepsis patients' renal manifestation on contrast-enhanced CT

    International Nuclear Information System (INIS)

    Sasaguri, K.; Yamaguchi, K.; Nakazono, T.; Mizuguchi, M.; Irie, H.

    2016-01-01

    Aim: To evaluate renal volume and attenuation changes in patients with sepsis on contrast-enhanced computed tomography (CT) with respect to the severity of sepsis. Materials and methods: Forty-four patients with sepsis who underwent CT before and after the onset of sepsis were retrospectively analysed. Renal volume and CT attenuation value of the renal cortex on contrast-enhanced CT were measured for each patient and changes in renal volume and CT attenuation value from before to after the onset of sepsis were calculated. The changes were correlated with the severity of sepsis (Sepsis-related Organ Failure Assessment [SOFA] score). The time course of the renal volume and CT attenuation changes were also evaluated. Results: Renal volume increased by 17.6% and CT attenuation value decreased by 19% after the onset of sepsis with statistically significant differences (p<0.001 for both renal volume and CT attenuation changes). The renal volume and CT attenuation changes had significant correlations with the SOFA score (r=0.36, p=0.018 and −0.43, p=0.005, respectively). The time course of the renal volume and CT attenuation changes seemed to be gradual compared to that of the SOFA score and to lag behind the peak of the SOFA score. Conclusion: In patients with sepsis, the renal volume increases and the CT attenuation value decreases in proportion to the severity of sepsis. The changes may lag behind the peak of severity of sepsis and can be observed for a relatively long time after a patient's recovery from sepsis. - Highlights: • The renal volume increases and the renal enhancement on contrast-enhanced CT decreases in patients with sepsis. • The degrees of these changes are correlated with severity of sepsis. • These changes may lag behind the peak of severity of sepsis and last for a long time after a patient's recovery from sepsis.

  11. Evaluation of breast lesions by contrast enhanced ultrasound: Qualitative and quantitative analysis

    International Nuclear Information System (INIS)

    Wan Caifeng; Du Jing; Fang Hua; Li Fenghua; Wang Lin

    2012-01-01

    Objective: To evaluate and compare the diagnostic performance of qualitative, quantitative and combined analysis for characterization of breast lesions in contrast enhanced ultrasound (CEUS), with histological results used as the reference standard. Methods: Ninety-one patients with 91 breast lesions BI-RADS 3–5 at US or mammography underwent CEUS. All lesions underwent qualitative and quantitative enhancement evaluation. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of different analytical method for discrimination between benign and malignant breast lesions. Results: Histopathologic analysis of the 91 lesions revealed 44 benign and 47 malignant. For qualitative analysis, benign and malignant lesions differ significantly in enhancement patterns (p z1 ), 0.768 (A z2 ) and 0.926(A z3 ) respectively. The values of A z1 and A z3 were significantly higher than that for A z2 (p = 0.024 and p = 0.008, respectively). But there was no significant difference between the values of A z1 and A z3 (p = 0.625). Conclusions: The diagnostic performance of qualitative and combined analysis was significantly higher than that for quantitative analysis. Although quantitative analysis has the potential to differentiate benign from malignant lesions, it has not yet improved the final diagnostic accuracy.

  12. Contrast-enhanced ultrasound evaluation of hepatic microvascular changes in liver diseases.

    Science.gov (United States)

    Ridolfi, Francesco; Abbattista, Teresa; Busilacchi, Paolo; Brunelli, Eugenio

    2012-10-07

    To assess if software assisted-contrast-enhanced ultrasonography (CEUS) provides reproducible perfusion parameters of hepatic parenchyma in patients affected by chronic liver disease. Forty patients with chronic viral liver disease, with (n = 20) or without (n = 20) cirrhosis, and 10 healthy subjects underwent CEUS and video recordings of each examination were then analysed with Esaote's Qontrast software. CEUS dedicated software Qontrast was used to determine peak (the maximum signal intensity), time to peak (TTP), region of blood value (RBV) proportional to the area under the time-intensity curve, mean transit time (MTT) measured in seconds and region of blood flow (RBF). Qontrast-assisted CEUS parameters displayed high inter-observer reproducibility (κ coefficients of 0.87 for MTT and 0.90 TTP). When the region of interest included a main hepatic vein, Qontrast-calculated TTP was significantly shorter in cirrhotic patients (vs non-cirrhotics and healthy subjects) (71.0 ± 11.3 s vs. 82.4 ± 15.6 s, 86.3 ± 20.3 s, P < 0.05). MTTs in the patients with liver cirrhosis were significantly shorter than those of controls (111.9 ± 22.0 s vs. 139.4 ± 39.8 s, P < 0.05), but there was no significant difference between the cirrhotic and non-cirrhotic groups (111.9 ± 22.0 s vs. 110.3 ± 14.6 s). Peak enhancement in the patients with liver cirrhosis was also higher than that observed in controls (23.9 ± 5.9 vs. 18.9 ± 7.1, P = 0.05). There were no significant intergroup differences in the RBVs and RBFs. Qontrast-assisted CEUS revealed reproducible differences in liver perfusion parameters during the development of hepatic fibrogenesis.

  13. Distribution of estimated glomerular filtration rate (eGFR) values in patients receiving contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Shimoji, Keigo; Aoki, Shigeki; Nakanishi, Atsushi

    2012-01-01

    The aim of this study was to elucidate the distribution of estimated glomerular filtration rate (eGFR) values in patients who underwent gadolinium-based contrast agent (GBCA)-enhanced magnetic resonance imaging (MRI) at different types of hospitals. We retrospectively studied 2,550 patients who underwent MRI at five institutions. We recorded the date and value of each patient's eGFR test. The distribution of eGFR values was compared with that in the general Japanese population. A total of 84.3% of patients had their eGFRs evaluated before GBCA-enhanced MRI. Of these, 84.7% were evaluated within 3 months before the GBCA-enhanced MRI, and 1.3% were evaluated on the day of the GBCA-enhanced MRI. A total of 87.2% of patients tested had an eGFR of ≥60 ml/min/1.73 m 2 ; 12.8% had an eGFR of 2 , and no patients had an eGFR of 2 . The rate of renal function evaluation differed among hospitals. The prevalence of low eGFR values was greater in Juntendo Tokyo Koto Geriatric Medical Center than in the other hospitals, and the prevalence of low eGFR values was greater in patients who underwent GBCA-enhanced MRI than in the general Japanese population. (author)

  14. Preoperative evaluation of neurovascular relationship by using contrast-enhanced and unenhanced 3D time-of-flight MR angiography in patients with trigeminal neuralgia

    International Nuclear Information System (INIS)

    Qin, Zhou; Zhiling, Liu; Chuanfu, Li; Qingshi Zeng; Chuncheng, Qu; Shilei, Ni

    2011-01-01

    Background Microvascular decompression is an etiological strategy for the therapy of trigeminal neuralgia (TN). Preoperative identification of neurovascular compression, therefore, could have an impact on the determination of appropriate treatment for TN. Purpose To evaluate the value of contrast-enhanced and unenhanced three-dimensional (3D) time-of-flight (TOF) MR angiography in the visualization of neurovascular relationship in patients with TN. Material and Methods Thirty-seven patients with unilateral TN underwent unenhanced and contrast-enhanced 3D TOF MR angiography with a 3.0-T MR system. Images were reviewed by a radiologist blinded to clinical details. Vascular contact with the trigeminal nerve was identified, and the nature of the involved vessels (artery or vein) was determined. All patients underwent microvascular decompression. Results In 37 patients with TN, contrast-enhanced 3D TOF MR angiography identified surgically verified neurovascular contact in 35 of 36 symptomatic nerves, and there was no false-positive. Based on surgical findings, the sensitivity of MR imaging was 97.2% and specificity 100%. The nature of the offending vessel was correctly identified in 94.4% of the patients by using the combination of contrast-enhanced and unenhanced MR angiography. Conclusion Contrast-enhanced 3D TOF MR angiography is useful in the detection of vascular contact with the trigeminal nerve in patients with TN, and this MR imaging in combination with unenhanced MR angiography could help in the identification of the nature of the responsible vessels

  15. Differentiation of benign and malignant solitary pulmonary nodules : value of contrast-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Kim, Jeong Ho; Kim, Hyung Jin; Han, Heon; Lee, Hong Lyeol; Kim, Kwang Ho; Suh, Chang Hae

    1999-01-01

    To evaluate the usefulness of contrast-enhanced dynamic MR imaging for differentiation of benign and malignant solitary pulmonary nodules (SPNs). Twenty-three patients with histologically or radiologically provened SPNs smaller than 40mm (14 benign, 9 malignant) underwent MR examination using the breath-hold fast multiplanar spoiled gradient echo (FMPSPGR) technique. Pre-enhancement MR examination was followed by serial scans obtained at one-minute intervals, beginning one-minute after the onset of bolus injection of paramagnetic contrast agent for a total of five scans. Signal intensities of SPNs were measured from pre- and post-contrast enhanced MR images and peak percentage increase in signal intensity (p%SI) was calculated. Mean percentage increase in signal intensity (m%SI) was also calculated and the time-m%SI curve was plotted. The enhancement patterns of SPNs were classified as homogeneous, peripheral rim-like, inhomogeneous, or no (or minimal) enhancement. We compared differences in p%SI, the pattern of the time-m%SI curve, and the pattern of enhancement between benign and malignant SPNs. On dynamic MR images, alignant SPNs (n=9) showed a significantly higher p%SI than benign SPNs (n=14) (malignant : mean 120.6, range 81.8-171.6; benign : mean 29.5, range 3.7-78.9)(p<0.0001). With 80 p%SI as the threshold for malignancy-positive, both sensitivity and specificity were 100%. The m%SI of malignant SPNs rapidly increased at one minute after enhancement and decreased gradually thereafter, whereas that of benign SPNs increased more slowly to form a plateau. Eighty-nine percent (8/9) of malignant SPNs showed homogeneous enhancement. In contrast, among benign SPNs, peripheral rim-like enhancement and no (or minimal) enhancement occurred in the same proportion of cases : 50%(7/14). The superb demonstration of different enhancement characteristics obtained using dynamic contrast-enhanced MR imaging is useful to discriminate malignant from benign SPNs

  16. Evaluation of the early enhancement of coronary atherosclerotic plaque by contrast-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Li Tao [Department of Radiology, The General Hospital of Chinese People' s Armed Police Forces, Number 69, Yong Ding Road, Hai Dian District, Beijing (China); Department of Radiology, Chinese People' s Liberation Army General Hospital, Number 28, Fu Xing Road, Hai Dian District, Beijing (China); Zhao Xihai [Department of Radiology, Chinese People' s Liberation Army General Hospital, Number 28, Fu Xing Road, Hai Dian District, Beijing (China); Liu Xin [Paul C. Lauterbur Biomedical Imaging Center, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Science, Shenzhen 518067 (China); Gao Jianhua [Department of Radiology, The General Hospital of Chinese People' s Armed Police Forces, Number 69, Yong Ding Road, Hai Dian District, Beijing (China); Zhao Shaohong [Department of Radiology, Chinese People' s Liberation Army General Hospital, Number 28, Fu Xing Road, Hai Dian District, Beijing (China); Li Xin; Zhou Weihua [Department of Radiology, The General Hospital of Chinese People' s Armed Police Forces, Number 69, Yong Ding Road, Hai Dian District, Beijing (China); Cai Zulong [Department of Radiology, Chinese People' s Liberation Army General Hospital, Number 28, Fu Xing Road, Hai Dian District, Beijing (China); Zhang Weiguo [Cardiovascular and Neurological Consulting Institute, 6771 San Fernando, Irving, TX 75039 (United States); Yang Li, E-mail: Yangli301@yahoo.com [Department of Radiology, Chinese People' s Liberation Army General Hospital, Number 28, Fu Xing Road, Hai Dian District, Beijing (China)

    2011-10-15

    Purpose: To evaluate the early enhancement of coronary atherosclerotic plaque using contrast-enhanced MR angiography (CE-MRA) and investigate the association between unstable angina pectoris (UAP) and early enhancement of the plaque. Methods: Forty-one patients presenting with angina pectoris and demonstrating single-vessel disease with non-calcified plaque and significant coronary stenosis ({>=}50%) on CTA were consecutively recruited for coronary CE-MRA. Contrast-to-noise ratio of the culprit plaque guided by CTA was measured on a cross-sectional multi-planar reconstruction image of the plaque on both pre- and post-CE-MRA. A 50% increasing of CNR was defined as plaque enhancement. The association between early enhancement of the plaques and UAP was analyzed. Results: Thirty-seven non-calcified plaques with significant coronary stenosis were detected in the 37 patients on MRA. 4 subjects were excluded because coronary atherosclerotic plaques were inadequate for identification on MRA. Of the 37 patients, 18 patients had UAP and other 19 patients presented stable angina pectoris (SAP). Of the 37 plaques on CE-MRA, 13 and 24 plaques presented early enhancement and no enhancement, respectively. Of the 13 early-enhanced plaques, 11 (85%) and 2 (15%) were found in the patients with UAP and SAP, respectively (p < 0.01). Of the 37 patients, 11 (61%) with UAP and 2 (11%) with SAP had early-enhanced plaques, respectively (p < 0.01). Conclusion: CE-MRA allows detection of early enhancement of coronary atherosclerotic plaque. The early enhancement is common in unstable angina and could be a sign of vulnerability.

  17. Evaluating automated dynamic contrast enhanced wrist 3T MRI in healthy volunteers

    DEFF Research Database (Denmark)

    Rastogi, Anshul; Kubassova, Olga; Krasnosselskaia, Lada V

    2013-01-01

    Dynamic contrast enhanced (DCE)-MRI has great potential to provide quantitative measure of inflammatory activity in rheumatoid arthritis. There is no current benchmark to establish the stability of signal in the joints of healthy subjects when imaged with DCE-MRI longitudinally, which is crucial so...

  18. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncică, Ana Maria; Săftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...... cancers and visualization of the portal venous system and esophageal varices. In addition, contrast agents can be used to differentiate pancreatic lesions. The use of color Doppler further increases the ability to diagnose and differentiate various pancreatic malignancies. The sensitivity of power Doppler...

  19. Serial contrast-enhanced magnetic resonance and magnetization transfer in the study of patients with multiple sclerosis

    International Nuclear Information System (INIS)

    Rovira, A.; Alonso, J.; Cucurella, G.; Nos, C.; Tintore, M.; Pedraza, S.; Rio, J.; Montalban, X.

    1997-01-01

    To demonstrate the changes in the magnetization transfer ratio (MTR) of different demyelinating plaques, correlating them with the baseline values in T1-weighted contrast-enhanced magnetic resonance (MR) sequences in order to relate them more closely to the underlying disease. The study was based on 33 demyelinating plaques obtained from six patients clinically diagnosed as having remitting-recurring multiple sclerosis (MS). All the patients underwent two MR studies at a 3 to 5-month interval, including contrast-enhanced T1 and T2- weighted sequences and magnetization transfer images. The latter were used to calculate the MTR for each of the demyelinating plaques included in the study. The statistical analysis of the results obtained revealed statistically significant between initial MTR values and those of subsequent T1-weighted sequences. The MTR demonstrate significant differences between plaques according to contrast-enhanced T1-weigh tes sequences, probably indicating variable degrees of edema, demyelination and tissue destruction. These differences should be taken into account to enable the use of T1-weighted sequences to quantify the lesion load in MS patients. (Author) 35 refs

  20. The characterization of small hypoattenuating renal masses on contrast-enhanced CT☆

    Science.gov (United States)

    Patel, Neesha S.; Poder, Liina; Wang, Zhen J.; Yeh, Benjamin M.; Qayyum, Aliya; Jin, Hua; Coakley, Fergus V.

    2011-01-01

    Purpose To determine if small hypoattenuating renal masses can be characterized as simple cysts or renal cell carcinomas on contrast-enhanced computed tomography (CT). Materials and methods We retrospectively identified 20 small (≤1.5 cm) hypoattenuating renal masses seen on contrast enhanced CT, consisting of 14 simple cysts and six renal cell carcinomas. Three independent readers recorded subjective visual impression (five-point scale from 1=definitely fluid to 5=definitely solid), CT attenuation, border (well circumscribed or ill defined), and shape (ovoid or irregular) for each lesion. Results The overall area under the receiver operator characteristic curves for subjective visual impression, CT attenuation, border, and shape were 0.97, 0.82, 0.59, and 0.55, respectively. Using dichotomized ratings (1–2=cyst and 3–5=carcinoma), subjective impression had a sensitivity and specificity of 100% and 79–100%, respectively, for the diagnosis of renal cell carcinoma. Using a threshold of 50 Hounsfield Units (HU) or more, CT attenuation had a sensitivity and specificity of 100% and 43–64%, respectively. Conclusion Small hypoattenuating renal masses can be characterized with reasonable accuracy by subjective impression and CT attenuation; lesions that appear solid on visual inspection or have an attenuation value of 50 HU or more are likely to be renal cell carcinoma. © 2009 Elsevier Inc. All rights reserved. PMID:19559352

  1. Value of fusion of PET and MRI for staging of endometrial cancer: Comparison with 18F-FDG contrast-enhanced PET/CT and dynamic contrast-enhanced pelvic MRI

    International Nuclear Information System (INIS)

    Kitajima, Kazuhiro; Suenaga, Yuko; Ueno, Yoshiko; Kanda, Tomonori; Maeda, Tetsuo; Takahashi, Satoru; Ebina, Yasuhiko; Miyahara, Yoshiya; Yamada, Hideto; Sugimura, Kazuro

    2013-01-01

    Purpose: To investigate the diagnostic value of retrospective fusion of pelvic MRI and 18 F-fluorodeoxyglucose ( 18 F-FDG) PET images for assessment of locoregional extension and nodal staging of endometrial cancer. Materials and methods: Thirty patients with biopsy-proven endometrial cancer underwent preoperative contrast-enhanced PET/CT (PET/ceCT) and pelvic dynamic contrast-enhanced MRI for initial staging. Diagnostic performance of PET/ceCT, contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) for assessing the extent of the primary tumor (T stage) and metastasis to regional LNs (N stage) was evaluated by two experienced readers. Histopathological and follow-up imaging results were used as the gold standard. The McNemar test was employed for statistical analysis. Results: Fused PET/MRI and MRI detected 96.7% of the primary tumors, whereas PET/ceCT detected 93.3%. Accuracy for T status was 80.0% for fused PET/MRI, and MRI proved significantly more accurate than PET/ceCT, which had an accuracy of 60.0% (p = 0.041). Patient-based sensitivity, specificity and accuracy for detecting pelvic nodal metastasis were 100%, 96.3% and 96.7% for both fused PET/MRI and PET/ceCT, and 66.7%, 100% and 96.7% for MRI, respectively. These three parameters were not statistically significant (p = 1). Conclusion: Fused PET/MRI, which complements the individual advantages of MRI and PET, is a valuable technique for assessment of the primary tumor and nodal staging in patients with endometrial cancer

  2. Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Jo, K.I.; Kim, S.R.; Choi, J.H.; Kim, K.H.; Jeon, P. [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Gangnam-gu, Seoul (Korea, Republic of)

    2015-11-15

    Contrast-enhanced cone-beam computed tomography (CBCT) has been introduced and accepted as a useful technique to evaluate delicate vascular anatomy and neurovascular stents. Current protocol for CBCT requires quantitative dilution of contrast medium to obtain adequate quality images. Here, we introduce simple methods to obtain contrast-enhanced CBCT without quantitative contrast dilution. A simple experiment was performed to estimate the change in flow rate in the internal carotid artery during the procedure. Transcranial doppler (TCD) was used to evaluate the velocity change before and after catheterization and fluid infusion. In addition, 0.3 cm{sup 3}/s (n = 3) and 0.2 cm{sup 3}/s (n = 7) contrast infusions were injected and followed by saline flushes using a 300 mmHg pressure bag to evaluate neurovascular stent and host arteries. Flow velocities changed -15 ± 6.8 % and +17 ± 5.5 % from baseline during catheterization and guiding catheter flushing with a 300 mmHg pressure bag, respectively. Evaluation of the stents and vascular structure was feasible using this technique in all patients. Quality assessment showed that the 0.2 cm{sup 3}/s contrast infusion protocol was better for evaluating the stent and host artery. Contrast-enhanced CBCT can be performed without quantitative contrast dilution. Adequate contrast dilution can be achieved with a small saline flush and normal blood flow. (orig.)

  3. Quantitative contrast-enhanced mammography for contrast medium kinetics studies

    Science.gov (United States)

    Arvanitis, C. D.; Speller, R.

    2009-10-01

    Quantitative contrast-enhanced mammography, based on a dual-energy approach, aims to extract quantitative and temporal information of the tumour enhancement after administration of iodinated vascular contrast media. Simulations using analytical expressions and optimization of critical parameters essential for the development of quantitative contrast-enhanced mammography are presented. The procedure has been experimentally evaluated using a tissue-equivalent phantom and an amorphous silicon active matrix flat panel imager. The x-ray beams were produced by a tungsten target tube and spectrally shaped using readily available materials. Measurement of iodine projected thickness in mg cm-2 has been performed. The effect of beam hardening does not introduce nonlinearities in the measurement of iodine projected thickness for values of thicknesses found in clinical investigations. However, scattered radiation introduces significant deviations from slope equal to unity when compared with the actual iodine projected thickness. Scatter correction before the analysis of the dual-energy images provides accurate iodine projected thickness measurements. At 10% of the exposure used in clinical mammography, signal-to-noise ratios in excess of 5 were achieved for iodine projected thicknesses less than 3 mg cm-2 within a 4 cm thick phantom. For the extraction of temporal information, a limited number of low-dose images were used with the phantom incorporating a flow of iodinated contrast medium. The results suggest that spatial and temporal information of iodinated contrast media can be used to indirectly measure the tumour microvessel density and determine its uptake and washout from breast tumours. The proposed method can significantly improve tumour detection in dense breasts. Its application to perform in situ x-ray biopsy and assessment of the oncolytic effect of anticancer agents is foreseeable.

  4. Imaging of the acute scrotum: is there a place for contrast-enhanced ultrasonography?

    Directory of Open Access Journals (Sweden)

    H. Moschouris

    2009-12-01

    Full Text Available Purpose: To present and evaluate the findings of contrast-enhanced ultrasonography (CEUS in typical cases of acute painful scrotum. Materials and methods: Nineteen patients aged from 19 to 61 years old were included in the study. All patients underwent grey-scale and color Doppler ultrasonography (US of the scrotum, followed by imaging after i.v. administration of 2.4 mL of a second generation ultrasound contrast agent (microbubbles of sulphur hexafluoride. A dedicated, contrast-sensitive technique was used (Contrast Tissue Imaging - CnTI. The diagnosis was confirmed surgically in 6 cases while in the remaining 8 cases it was based on the combination of clinical, imaging and laboratory findings. Results: The final diagnosis was testicular torsion (n = 4, epididymitis (n = 2, one of the cases complicated by abscess, testicular abscess (n = 1, scrotal abscess (n = 1, testicular trauma of varying severity (n = 6. Five out of 19 cases were true negatives: neither clinical examination nor laboratory tests revealed any pathology. CEUS showed complete lack of enhancement in all cases of torsion, permitting a rapid and definitive diagnosis. In the cases of infection complicated by abscesses, CEUS delineated the lesions much better than the combination of B-mode/Color Doppler US. The severely traumatized testicles showed minimal, inhomogeneous or patchy enhancement, while cases of minor trauma showed no significant enhancement defects. Hematomas were presented as non-enhancing lesions. Conclusion: Generally, there was no advantage over Doppler US as has been previously shown. However, CEUS can be used supplementary to traditional Doppler US in the investigation of blunt testicular trauma especially when there is uncertainty in diagnosis after appropriate clinical and radiographic evaluations occurs. Further studies are required to clearly define the indications of this method.

  5. Quantitative evaluation of contrast-enhanced ultrasound after intravenous administration of a microbubble contrast agent for differentiation of benign and malignant thyroid nodules: assessment of diagnostic accuracy.

    Science.gov (United States)

    Nemec, Ursula; Nemec, Stefan F; Novotny, Clemens; Weber, Michael; Czerny, Christian; Krestan, Christian R

    2012-06-01

    To investigate the diagnostic accuracy, through quantitative analysis, of contrast-enhanced ultrasound (CEUS), using a microbubble contrast agent, in the differentiation of thyroid nodules. This prospective study enrolled 46 patients with solitary, scintigraphically non-functional thyroid nodules. These patients were scheduled for surgery and underwent preoperative CEUS with pulse-inversion harmonic imaging after intravenous microbubble contrast medium administration. Using histology as a standard of reference, time-intensity curves of benign and malignant nodules were compared by means of peak enhancement and wash-out enhancement relative to the baseline intensity using a mixed model ANOVA. ROC analysis was performed to assess the diagnostic accuracy in the differentiation of benign and malignant nodules on CEUS. The complete CEUS data of 42 patients (31/42 [73.8%] benign and 11/42 [26.2%] malignant nodules) revealed a significant difference (P benign and malignant nodules. Furthermore, based on ROC analysis, CEUS demonstrated sensitivity of 76.9%, specificity of 84.8% and accuracy of 82.6%. Quantitative analysis of CEUS using a microbubble contrast agent allows the differentiation of benign and malignant thyroid nodules and may potentially serve, in addition to grey-scale and Doppler ultrasound, as an adjunctive tool in the assessment of patients with thyroid nodules. • Contrast-enhanced ultrasound (CEUS) helps differentiate between benign and malignant thyroid nodules. • Quantitative CEUS analysis yields sensitivity of 76.9% and specificity of 84.8%. • CEUS may be a potentially useful adjunct in assessing thyroid nodules.

  6. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, Pierre-Alexandre, E-mail: Pierre-Alexandre.Poletti@hcuge.ch [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Buchs, Nicolas [Department of Surgery, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Shanmuganathan, Kathirkamanathan [Department of Diagnostic Radiology and Nuclear Medicine, 22 S. Greene Street, Baltimore, MD 21201 (United States); Platon, Alexandra [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland)

    2013-11-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT.

  7. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    International Nuclear Information System (INIS)

    Poletti, Pierre-Alexandre; Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain; Buchs, Nicolas; Shanmuganathan, Kathirkamanathan; Platon, Alexandra

    2013-01-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT

  8. Contrast-enhanced ultrasound-guided radiofrequency ablation in inconspicuous hepatocellular carcinoma on B-mode ultrasound.

    Science.gov (United States)

    Kim, Eui Joo; Kim, Yun Soo; Shin, Seung Kak; Kwon, Oh Sang; Choi, Duck Joo; Kim, Ju Hyun

    2017-11-01

    B-mode ultrasound (US) has difficulty targeting small hepatocellular carcinomas (HCCs) with poor conspicuity during radiofrequency ablation (RFA). Contrast-enhanced ultrasound (CEUS) can improve visualization of small or inconspicuous HCCs. This study was conducted to evaluate the effectiveness of CEUS-guided RFA electrode insertion during the arterial phase in inconspicuous HCCs. Ninety-three treatment-naïve HCCs from 80 patients treated with RFA from August 2012 to December 2014 were retrospectively reviewed. Seventy-five HCCs from 65 patients underwent B-mode US-guided RFA, and 15 HCCs from 14 patients that were inconspicuous on B-mode US underwent CEUS-guided RFA during the arterial phase after injection of sulfur hexafluoride microbubbles (SonoVue®). Technical success was assessed by contrast-enhanced computed tomography within 1 week and 3 months after the procedure. The mean size of HCCs treated with CEUS-guided RFA was smaller than that of HCCs treated with B-mode US-guided RFA (1.17±0.36 vs. 1.63±0.55 cm, p=0.003). Technical success rates of CEUS-guided RFA within 1 week and 3 months were 100% (15/15) and 93.3% (14/15), respectively. Technical success rates of B-mode US-guided RFA were 97.3% (73/75) and 94.5% (69/73), respectively. CEUS-guided RFA is highly efficacious for ablation of very small and inconspicuous HCCs.

  9. Bile duct evaluation of potential living liver donors with Gd-EOB-DTPA enhanced MR cholangiography: Single-dose, double dose or half-dose contrast enhanced imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja, E-mail: Sonja.Kinner@uni-due.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Steinweg, Verena [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Maderwald, Stefan [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Radtke, Arnold; Sotiropoulos, Georgios [Department of General Surgery, University Hospital Essen (Germany); Forsting, Michael; Schroeder, Tobias [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany)

    2014-05-15

    Introduction: Detailed knowledge of the biliary anatomy is essential to avoid complications in living donor liver transplantation. The aim of this study was to determine the optimal dosage of Gd-EOB-DTPA for contrast-enhanced magnetic resonance cholangiography (ce-MRC) with reference to contrast-enhanced CT cholangiography (ce-CTC). Materials and methods: 30 potential living liver donors (PLLD) underwent both ce-CTC and ce-MRC. Ten candidates each received single, double or half-dose Gd-EOB-DTPA. Ce-MRC images with and without inversion recovery pulses (T1w ± IR) were acquired 20–30 min after intravenous contrast injection. Image data was quantitatively and qualitatively reviewed by two radiologists based on a on a 5-point scale. Data sets were compared using a Mann–Whitney-U-test or Wilcoxon-rank-sum-test. Kappa values were also calculated. Results: All image series provided sufficient diagnostic information both showing normal biliary anatomy and variant bile ducts. Ce-CTC showed statistically significant better results compared to all ce-MRC data sets. T1w MRC with single dose Gd-EOB-DTPA proved to be superior to half and double dose in subjective and objective evaluation without a statistically significant difference. Conclusions: Ce-MRC is at any dosage inferior to ce-CTC. As far as preoperative planning of bile duct surgery is focused on the central biliary anatomy, ce-MRC can replace harmful ce-CTC strategies, anyway. Best results were seen with single dose GD-EOB-DTPA on T1w MRC+IR.

  10. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Hayato, E-mail: m04149@yahoo.co.jp [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Yamada, Takayuki; Murakami, Kenji; Hashimoto, Kazuki; Tazawa, Yoko; Kumano, Reiko [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Nakajima, Yasuo [Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa 216-8511 (Japan)

    2015-05-15

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  11. Clinical impact of EUS elastography followed by contrast-enhanced EUS in patients with focal pancreatic masses and negative EUS-guided FNA

    DEFF Research Database (Denmark)

    Iordache, Sevastiţa; Costache, Mădălin Ionuţ; Popescu, Carmen Florina

    2016-01-01

    and negative cytopathology after EUS-FNA, based on previously published results and cut-offs of real-time elastographic (RTE) EUS and contrast-enhanced harmonic (CEH) EUS. MATERIAL AND METHODS: We included in the study a subgroup of 50 consecutive patients with focal pancreatic masses which underwent EUS...... malignancy, the sensitivity, specificity and accuracy of RTE-EUS were: 97.7%, 77.4%, and 84% respectively. CEH-EUS had similar results: 89.5%, 80.7%, and 84%, respectively. In 25 patients with soft/mixed appearance during elastography,sequential assessment using contrast-enhanced EUSwas performed...

  12. Visual Contrast Enhancement Algorithm Based on Histogram Equalization

    Science.gov (United States)

    Ting, Chih-Chung; Wu, Bing-Fei; Chung, Meng-Liang; Chiu, Chung-Cheng; Wu, Ya-Ching

    2015-01-01

    Image enhancement techniques primarily improve the contrast of an image to lend it a better appearance. One of the popular enhancement methods is histogram equalization (HE) because of its simplicity and effectiveness. However, it is rarely applied to consumer electronics products because it can cause excessive contrast enhancement and feature loss problems. These problems make the images processed by HE look unnatural and introduce unwanted artifacts in them. In this study, a visual contrast enhancement algorithm (VCEA) based on HE is proposed. VCEA considers the requirements of the human visual perception in order to address the drawbacks of HE. It effectively solves the excessive contrast enhancement problem by adjusting the spaces between two adjacent gray values of the HE histogram. In addition, VCEA reduces the effects of the feature loss problem by using the obtained spaces. Furthermore, VCEA enhances the detailed textures of an image to generate an enhanced image with better visual quality. Experimental results show that images obtained by applying VCEA have higher contrast and are more suited to human visual perception than those processed by HE and other HE-based methods. PMID:26184219

  13. Visual Contrast Enhancement Algorithm Based on Histogram Equalization

    Directory of Open Access Journals (Sweden)

    Chih-Chung Ting

    2015-07-01

    Full Text Available Image enhancement techniques primarily improve the contrast of an image to lend it a better appearance. One of the popular enhancement methods is histogram equalization (HE because of its simplicity and effectiveness. However, it is rarely applied to consumer electronics products because it can cause excessive contrast enhancement and feature loss problems. These problems make the images processed by HE look unnatural and introduce unwanted artifacts in them. In this study, a visual contrast enhancement algorithm (VCEA based on HE is proposed. VCEA considers the requirements of the human visual perception in order to address the drawbacks of HE. It effectively solves the excessive contrast enhancement problem by adjusting the spaces between two adjacent gray values of the HE histogram. In addition, VCEA reduces the effects of the feature loss problem by using the obtained spaces. Furthermore, VCEA enhances the detailed textures of an image to generate an enhanced image with better visual quality. Experimental results show that images obtained by applying VCEA have higher contrast and are more suited to human visual perception than those processed by HE and other HE-based methods.

  14. Influence of Contrast Media on Bone Mineral Density (BMD) Measurements from Routine Contrast-Enhanced MDCT Datasets using a Phantom-less BMD Measurement Tool.

    Science.gov (United States)

    Toelly, Andrea; Bardach, Constanze; Weber, Michael; Gong, Rui; Lai, Yanbo; Wang, Pei; Guo, Yulin; Kirschke, Jan; Baum, Thomas; Gruber, Michael

    2017-06-01

    Aim  To evaluate the differences in phantom-less bone mineral density (BMD) measurements in contrast-enhanced routine MDCT scans at different contrast phases, and to develop an algorithm for calculating a reliable BMD value. Materials and Methods  112 postmenopausal women from the age of 40 to 77 years (mean age: 57.31 years; SD 9.61) who underwent a clinically indicated MDCT scan, consisting of an unenhanced, an arterial, and a venous phase, were included. A retrospective analysis of the BMD values of the Th12 to L4 vertebrae in each phase was performed using a commercially available phantom-less measurement tool. Results  The mean BMD value in the unenhanced MDCT scans was 79.76 mg/cm³ (SD 31.20), in the arterial phase it was 85.09 mg/cm³ (SD 31.61), and in the venous phase it was 86.18 mg/cm³ (SD 31.30). A significant difference (p Influence of Contrast Media on Bone Mineral Density (BMD) Measurements from Routine Contrast-Enhanced MDCT Datasets using a Phantom-less BMD Measurement Tool. Fortschr Röntgenstr 2017; 189: 537 - 543. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Abdominal 64-MDCT for suspected appendicitis: the use of oral and IV contrast material versus IV contrast material only.

    Science.gov (United States)

    Anderson, Stephan W; Soto, Jorge A; Lucey, Brian C; Ozonoff, Al; Jordan, Jacqueline D; Ratevosian, Jirair; Ulrich, Andrew S; Rathlev, Niels K; Mitchell, Patricia M; Rebholz, Casey; Feldman, James A; Rhea, James T

    2009-11-01

    The objective of our study was to compare the diagnostic accuracy of IV contrast-enhanced 64-MDCT with and without the use of oral contrast material in diagnosing appendicitis in patients with abdominal pain. We conducted a randomized trial of a convenience sample of adult patients presenting to an urban academic emergency department with acute nontraumatic abdominal pain and clinical suspicion of appendicitis, diverticulitis, or small-bowel obstruction. Patients were enrolled between 8 am and 11 pm when research assistants were present. Consenting subjects were randomized into one of two groups: Group 1 subjects underwent 64-MDCT performed with oral and IV contrast media and group 2 subjects underwent 64-MDCT performed solely with IV contrast material. Three expert radiologists independently reviewed the CT examinations, evaluating for the presence of appendicitis. Each radiologist interpreted 202 examinations, ensuring that each examination was interpreted by two radiologists. Individual reader performance and a combined interpretation performance of the two readers assigned to each case were calculated. In cases of disagreement, the third reader was asked to deliver a tiebreaker interpretation to be used to calculate the combined reader performance. Final outcome was based on operative, clinical, and follow-up data. We compared radiologic diagnoses with clinical outcomes to calculate the diagnostic accuracy of CT in both groups. Of the 303 patients enrolled, 151 patients (50%) were randomized to group 1 and the remaining 152 (50%) were randomized to group 2. The combined reader performance for the diagnosis of appendicitis in group 1 was a sensitivity of 100% (95% CI, 76.8-100%) and specificity of 97.1% (95% CI, 92.7-99.2%). The performance in group 2 was a sensitivity of 100% (73.5-100%) and specificity of 97.1% (92.9-99.2%). Patients presenting with nontraumatic abdominal pain imaged using 64-MDCT with isotropic reformations had similar characteristics for the

  16. The value of contrast-enhanced 64-row CT in differentiating benign from malignant serous ovarian neoplasms

    International Nuclear Information System (INIS)

    Dong Tianfa; Wu Meixian; Zhang Jiayun; Song Ting

    2009-01-01

    Objective: To assess the diagnostic value of contrast-enhanced 64-row CT scanning in deciding benign or malignant serous ovarian tumors. Methods: Fifty-eight cases of serous ovarian tumors proved pathologically were reviewed, including 25 malignant tumors, 25 benign, 8 borderline tumors. All patients underwent 64-row CT scanning, including plain scanning and contrast-enhance scanning. The tumors' shape, density, blood supply and enhancement features were evaluated. Results: Twenty-five cases of benign serous cystic adenoma were mostly unicameral, and showed a moderate mural enhancement only in 4 cases (16%) due to chronic pelvic infection and the others (21/25, 84%) had no of slight enhancement. Malignant tumors were cystic-solid mass with unclear margin, irregular shape and septa. Twenty-two cases of serous cystadenocarcinoma out of 25 cases (88%) appeared obvious enhancement and other 3 cases no enhancement. And 7 cases out of 8 (87.5%) borderlined serous cystadenomas showed different enhancement patterns. Conclusion: Benign ovarian serous neoplasms were mostly unicameral and no strong mural enhancement, suggesting a lack of blood supply. While, there were obvious enhancement in the ovarian serous cystadenocarcinoma and borderline serous cystadenoma with malignant potential. The 64-row CT is helpful for differentiating the nature of the serous ovarian neoplasm. (authors)

  17. Improved wrist pannus volume measurement from contrast-enhanced MRI in rheumatoid arthritis using shuffle transform.

    Science.gov (United States)

    Xanthopoulos, Emily; Hutchinson, Charles E; Adams, Judith E; Bruce, Ian N; Nash, Anthony F P; Holmes, Andrew P; Taylor, Christopher J; Waterton, John C

    2007-01-01

    Contrast-enhanced MRI is of value in assessing rheumatoid pannus in the hand, but the images are not always easy to quantitate. To develop and evaluate an improved measurement of volume of enhancing pannus (VEP) in the hand in human rheumatoid arthritis (RA). MR images of the hand and wrist were obtained for 14 patients with RA at 0, 1 and 13 weeks. Volume of enhancing pannus was measured on images created by subtracting precontrast T1-weighted images from contrast-enhanced T1-weighted images using a shuffle transformation technique. Maximum intensity projection (MIP) and 3D volume rendering of the images were used as a guide to identify the pannus and any contrast-enhanced veins. Visualisation of pannus was much improved following the shuffle transform. Between 0 weeks and 1 week, the mean value of the within-subject coefficient of variation (CoV) was 0.13 and the estimated total CoV was 0.15. There was no evidence of significant increased variability within the 13-week interval for the complete sample of patients. Volume of enhancing pannus can be measured reproducibly in the rheumatoid hand using 3D contrast-enhanced MRI and shuffle transform.

  18. Value of fusion of PET and MRI for staging of endometrial cancer: Comparison with {sup 18}F-FDG contrast-enhanced PET/CT and dynamic contrast-enhanced pelvic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Suenaga, Yuko; Ueno, Yoshiko [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Kanda, Tomonori [Department of Obsterics and Gynecology of Kobe University School of Medicine, Kobe (Japan); Department of Radiology, Hyogo Cancer Center, Hyogo (Japan); Maeda, Tetsuo; Takahashi, Satoru [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Ebina, Yasuhiko; Miyahara, Yoshiya; Yamada, Hideto [Department of Obsterics and Gynecology of Kobe University School of Medicine, Kobe (Japan); Department of Radiology, Hyogo Cancer Center, Hyogo (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University School of Medicine, Kobe (Japan)

    2013-10-01

    Purpose: To investigate the diagnostic value of retrospective fusion of pelvic MRI and {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET images for assessment of locoregional extension and nodal staging of endometrial cancer. Materials and methods: Thirty patients with biopsy-proven endometrial cancer underwent preoperative contrast-enhanced PET/CT (PET/ceCT) and pelvic dynamic contrast-enhanced MRI for initial staging. Diagnostic performance of PET/ceCT, contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) for assessing the extent of the primary tumor (T stage) and metastasis to regional LNs (N stage) was evaluated by two experienced readers. Histopathological and follow-up imaging results were used as the gold standard. The McNemar test was employed for statistical analysis. Results: Fused PET/MRI and MRI detected 96.7% of the primary tumors, whereas PET/ceCT detected 93.3%. Accuracy for T status was 80.0% for fused PET/MRI, and MRI proved significantly more accurate than PET/ceCT, which had an accuracy of 60.0% (p = 0.041). Patient-based sensitivity, specificity and accuracy for detecting pelvic nodal metastasis were 100%, 96.3% and 96.7% for both fused PET/MRI and PET/ceCT, and 66.7%, 100% and 96.7% for MRI, respectively. These three parameters were not statistically significant (p = 1). Conclusion: Fused PET/MRI, which complements the individual advantages of MRI and PET, is a valuable technique for assessment of the primary tumor and nodal staging in patients with endometrial cancer.

  19. A Novel Contrast Enhancement Technique on Palm Bone Images

    Directory of Open Access Journals (Sweden)

    Yung-Tsang Chang

    2014-09-01

    Full Text Available Contrast enhancement plays a fundamental role in image processing. Many histogram-based techniques are widely used for contrast enhancement of given images, due to their simple function and effectiveness. However, the conventional histogram equalization (HE methods result in excessive contrast enhancement, which causes natural looking and satisfactory results for a variety of low contrast images. To solve such problems, a novel multi-histogram equalization technique is proposed to enhance the contrast of the palm bone X-ray radiographs in this paper. For images, the mean-variance analysis method is employed to partition the histogram of the original grey scale image into multiple sub-histograms. These histograms are independently equalized. By using this mean-variance partition method, a proposed multi-histogram equalization technique is employed to achieve the contrast enhancement of the palm bone X-ray radiographs. Experimental results show that the multi-histogram equalization technique achieves a lower average absolute mean brightness error (AMBE value. The multi-histogram equalization technique simultaneously preserved the mean brightness and enhanced the local contrast of the original image.

  20. Dual-energy contrast-enhanced mammography.

    Science.gov (United States)

    Travieso Aja, M M; Rodríguez Rodríguez, M; Alayón Hernández, S; Vega Benítez, V; Luzardo, O P

    2014-01-01

    The degree of vascularization in breast lesions is related to their malignancy. For this reason, functional diagnostic imaging techniques have become important in recent years. Dual-energy contrast-enhanced mammography is a new, apparently promising technique in breast cancer that provides information about the degree of vascularization of the lesion in addition to the morphological information provided by conventional mammography. This article describes the state of the art for dual-energy contrast-enhanced mammography. Based on 15 months' clinical experience, we illustrate this review with clinical cases that allow us to discuss the advantages and limitations of this technique. Copyright © 2014 SERAM. Published by Elsevier Espana. All rights reserved.

  1. Diagnosis value of dual-phase contrast enhancement CT combined with virtual non-enhanced images by dual-energy CT in clear cell renal cell carcinoma

    International Nuclear Information System (INIS)

    Ma Zhoupeng; Zhou Jianjun; Liu Xueling; Wang Chun; Zhang Shunzhuang

    2012-01-01

    Objective: To explore the diagnostic value of dual-phase contrast enhancement CT combined with virtual non-enhanced images by dual-energy CT in clear cell renal cell carcinoma. Methods: Sixty patients who were suspected of clear cell renal cell carcinoma underwent non-enhanced CT and contrast enhancement CT of early interface-phase between cortex -medulla and parenchymal phase on a dual-energy CT. The true non-enhanced kidney CT (TNCT) was performed in a single-energy acquisition mode, but the dual-phase contrast enhancement CT were performed in a dual-energy mode of 80 kV and 140 kV respectively. The virtual non-enhanced CT (VNCT) images were derived from the data of early interface phase using liver virtual non-contrast software. The diagnose according to VNCT combined dual-phase contrast enhancement CT and dual-phase contrast enhancement CT only were made respectively and compared with χ 2 test. Between the true non-contrast CT and the virtual non-contrast CT, the image quality was compared with Wilcoxon test; The radiation dose of volume CT dose index (CTDIvol) and dose length product(DLP) in a single-phase and total examination, the mean CT HU values of the tumours were compared with t test. Results: The accuracy of VNCT combined dual-phase contrast enhancement CT was higher than that of dual-phase contrast enhancement CT only [93.3% (56/60) vs.78.3% (47/60); χ 2 =5.6, P<0.05]. The detective ability (score) of VNCT was near to that of TNCT and the difference was not obvious (Z=0.00, P>0.05). The radiation dose of volume CT dose index (CTDIvol) and dose length product (DLP) in a single phase and total examination of VNCT [(8.85 ± 1.28) mGy, (196.45 ±21.12) mGy·cm, (17.69±2.35) mGy, (392.90±42.25) mGy · cm] were lower than that of TNCT [(10.20 ± 1.44) mGy,(218.29 ± 29.60) mGy · cm, (30.61 ± 3.27) mGy and (654.86 ± 88.81) mGy ·cm], t=4.21, 3.58, 23.63, 16.12 respectively, P<0.05. The mean CT HU values of tumours on VNCT images was higher than that

  2. Magnetic resonance imaging of urinary bladder carcinoma: tumor staging and gadolinium contrast-enhanced imaging

    International Nuclear Information System (INIS)

    Doringer, E.; Joos, H.; Forstner, R.; Schmoller, H.

    1992-01-01

    Forty-nine patients with urinary bladder carcinomas underwent pre-operative examinations using magnetic resonance (MR) imaging. The results of the MR examinations were correlated with the clinical-pathological findings following transurethral resection (TUR) and bimanual palpation (n = 47) or radical cystectomy (n = 2). The results of pre-contrast MR tumor staging (T1, T2), viewing stages Tis-T2 collectively, and subsequent to separate assessments of stages T3b-T4b, were correct 76.6% of the time. Gadolinium-DTPA (Gd-DTPA) contrast-enhanced examinations (pre-contrast T1 and after Gd-DTPA) showed a staging accuracy rate of 85.7%. T2-weighted images did not indicate any advantage when compared to T1-weighted images following Gd-DTPA. The signal intensity ratios of tumor/fat and tumor/muscle tissue were measured on T1-weighted pre-contrast images and following Gd-DTPA and then evaluated statistically, whereby the increased tumor signal intensity was statistically significant (Wilcoxon test, P < 0.01). Due to the relatively short examination time needed for T1-weighted images and the specific tumor enhancement, the administration of Gd-DTPA proves valuable in the diagnosis of bladder carcinomas. T2-weighted images are not necessary. (orig.)

  3. Dual-energy contrast-enhanced spectral mammography (CESM).

    Science.gov (United States)

    Daniaux, Martin; De Zordo, Tobias; Santner, Wolfram; Amort, Birgit; Koppelstätter, Florian; Jaschke, Werner; Dromain, Clarisse; Oberaigner, Willi; Hubalek, Michael; Marth, Christian

    2015-10-01

    Dual-energy contrast-enhanced mammography is one of the latest developments in breast care. Imaging with contrast agents in breast cancer was already known from previous magnetic resonance imaging and computed tomography studies. However, high costs, limited availability-or high radiation dose-led to the development of contrast-enhanced spectral mammography (CESM). We reviewed the current literature, present our experience, discuss the advantages and drawbacks of CESM and look at the future of this innovative technique.

  4. Characterization of the enhancing lesions on dynamic contrast enhanced magnetic resonance imaging in patients with interstitial mammoplasty

    International Nuclear Information System (INIS)

    Kim, Tae Yun; Kim, Sung Hun; Kang, Bong Joo; Kim, Hyeon Sook; Cha, Eun Suk; Kim, Ji Youn; Song, Byung Joo

    2013-01-01

    Purpose: The purpose of this study was to categorize the morphologic and kinetic features of enhancing lesions in breasts with interstitial mammoplasty using dynamic contrast-enhanced magnetic resonance imaging and to assess factors predictive of breast cancer. Materials and methods: We retrospectively reviewed the clinical and radiological data of 21 enhancing lesions in 19 patients with interstitial mammoplasty, who underwent breast magnetic resonance imaging and biopsy or an operation in our hospital from September 2008 to July 2012. These lesions were sorted by morphological and kinetic features and final assessment category according to the BI-RADS lexicon. Results: Nine cases were confirmed to be ductal carcinoma in situ (n = 2) and invasive ductal carcinoma (n = 7), and the remaining 12 cases were fibrocystic disease (n = 2), fibroadenoma (n = 2), fat necrosis (n = 1), foreign body granuloma (n = 3) and silicone mastitis (n = 1). Common features of malignancy included irregular shape (50.0%), spiculated margins (75.0%), heterogeneous enhancement (50.0%) and type III kinetic pattern (87.5%). The correlations of margins and kinetic curve pattern with benignity and malignancy approached statistical significance (p = 0.02, respectively). We found no correlation for shape (p = 0.33) or internal enhancement (p = 0.42) between lesion types. The malignancy rate of enhancing lesions was 42.8% (9/21). The sensitivity and specificity of dynamic contrast-enhanced magnetic resonance imaging were 100% and 16.67%, respectively. The positive predictive value, negative predictive value and accuracy of magnetic resonance imaging were 47.38%, 100% and 52.38%. Overall inter-observer agreement for the kinetic curve pattern was good (κ = 0.67). Moderate agreement was seen in describing the shape, margin, enhancement and assessing the final category (κ = 0.59, 0.46, 0.58 and 0.49, respectively). Conclusion: Dynamic contrast-enhanced magnetic resonance imaging had a high

  5. Characterization of the enhancing lesions on dynamic contrast enhanced magnetic resonance imaging in patients with interstitial mammoplasty

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Yun [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kim, Sung Hun, E-mail: rad-ksh@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kang, Bong Joo [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kim, Hyeon Sook [Department of Radiology, St. Paul Hospital, The Catholic University of Korea (Korea, Republic of); Cha, Eun Suk [Department of Radiology, Ewha Womans University, School of Medicine, Mokdong Hospital (Korea, Republic of); Kim, Ji Youn [Department of Radiology, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Song, Byung Joo [Department of Surgery, Seoul St. Mary' s Hospital, The Catholic University of Korea, Seoul (Korea, Republic of)

    2013-12-01

    Purpose: The purpose of this study was to categorize the morphologic and kinetic features of enhancing lesions in breasts with interstitial mammoplasty using dynamic contrast-enhanced magnetic resonance imaging and to assess factors predictive of breast cancer. Materials and methods: We retrospectively reviewed the clinical and radiological data of 21 enhancing lesions in 19 patients with interstitial mammoplasty, who underwent breast magnetic resonance imaging and biopsy or an operation in our hospital from September 2008 to July 2012. These lesions were sorted by morphological and kinetic features and final assessment category according to the BI-RADS lexicon. Results: Nine cases were confirmed to be ductal carcinoma in situ (n = 2) and invasive ductal carcinoma (n = 7), and the remaining 12 cases were fibrocystic disease (n = 2), fibroadenoma (n = 2), fat necrosis (n = 1), foreign body granuloma (n = 3) and silicone mastitis (n = 1). Common features of malignancy included irregular shape (50.0%), spiculated margins (75.0%), heterogeneous enhancement (50.0%) and type III kinetic pattern (87.5%). The correlations of margins and kinetic curve pattern with benignity and malignancy approached statistical significance (p = 0.02, respectively). We found no correlation for shape (p = 0.33) or internal enhancement (p = 0.42) between lesion types. The malignancy rate of enhancing lesions was 42.8% (9/21). The sensitivity and specificity of dynamic contrast-enhanced magnetic resonance imaging were 100% and 16.67%, respectively. The positive predictive value, negative predictive value and accuracy of magnetic resonance imaging were 47.38%, 100% and 52.38%. Overall inter-observer agreement for the kinetic curve pattern was good (κ = 0.67). Moderate agreement was seen in describing the shape, margin, enhancement and assessing the final category (κ = 0.59, 0.46, 0.58 and 0.49, respectively). Conclusion: Dynamic contrast-enhanced magnetic resonance imaging had a high

  6. Morphological rational operator for contrast enhancement.

    Science.gov (United States)

    Peregrina-Barreto, Hayde; Herrera-Navarro, Ana M; Morales-Hernández, Luis A; Terol-Villalobos, Iván R

    2011-03-01

    Contrast enhancement is an important task in image processing that is commonly used as a preprocessing step to improve the images for other tasks such as segmentation. However, some methods for contrast improvement that work well in low-contrast regions affect good contrast regions as well. This occurs due to the fact that some elements may vanish. A method focused on images with different luminance conditions is introduced in the present work. The proposed method is based on morphological transformations by reconstruction and rational operations, which, altogether, allow a more accurate contrast enhancement resulting in regions that are in harmony with their environment. Furthermore, due to the properties of these morphological transformations, the creation of new elements on the image is avoided. The processing is carried out on luminance values in the u'v'Y color space, which avoids the creation of new colors. As a result of the previous considerations, the proposed method keeps the natural color appearance of the image.

  7. Dynamic contrast-enhanced CT appearances of the intraductal papillary neoplasms of the bile duct

    International Nuclear Information System (INIS)

    Song Fengxiang; Zhou Jianjun; Zeng Mengsu; Zhou Kangrong; Ding Yuqin; He Deming; Shi Yuxin; Zhou Jun

    2013-01-01

    Objective: To analyze the dynamic contrast-enhanced CT appearances of intraductal papillary neoplasms of the bile duct and improve its diagnostic accuracy. Methods: Sixteen patients with intraductal papillary neoplasms of the bile duct confirmed histopathologically after surgical operation underwent dynamic contrast-enhanced multi-detector row CT scans. All imaging data were reviewed and analyzed retrospectively in correlation with surgical and pathological findings. CT values of 38 well-visualized lesions in 12 of the 16 patients at the pre-contrast phase, arterial phase and venous phase were measured. Four of the 12 patients with 17 lesions had benign tumors, and 8 of the 12 patients with 21 lesions had malignant tumors. Comparisons of CT values at the three phases between the two groups were carried out using independent sample t test. The bile CT values were measured in these 12 cases, 40 normal volunteers, and 40 subjects with bile duct stones, and the Wilcoxon signed-rank test was applied to compare the bile CT values between tumor group and the normal group and between tumor group and the bile duct stone group. The diameters of the bile ducts proximal to and distal to tumors were also measured, and Fisher exact method was carried to analyze the data. Results: Lesions located at the left lobe in 8 out of the 16 patients, the right lobe in 1 case, both the left and right lobes in 1 case, the hepatic hilum in 1 case, the common bile duct in 3 cases, and both the right lobe and the common bile duct in 2 cases. Eleven lesions appeared as papillary masses, 3 as flat masses, 1 as mixed papillary and flat masses. In one case, tumor mass could not be definitely visualized, and only dilated bile ducts and stones were demonstrated. The mean CT values of the benign tumors were (25.8 ± 8.0), (37.7 ± 10.3) and (51.7 ± 17.1) HU respectively at pre-contrast phase, arterial phase, and venous phase, and the malignant tumors were (38.4 ± 10.2), (56.6 ± 18.0) and (68.4

  8. The Future of Contrast-Enhanced Mammography.

    Science.gov (United States)

    Covington, Matthew F; Pizzitola, Victor J; Lorans, Roxanne; Pockaj, Barbara A; Northfelt, Donald W; Appleton, Catherine M; Patel, Bhavika K

    2018-02-01

    The purpose of this article is to discuss facilitators of and barriers to future implementation of contrast-enhanced mammography (CEM) in the United States. CEM provides low-energy 2D mammographic images analogous to digital mammography and contrast-enhanced recombined images that allow assessment of neovascularity similar to that offered by MRI. The utilization of CEM in the United States is currently low but could increase rapidly given the many potential indications for its clinical use.

  9. Contrast-enhanced power Doppler US of hepatocellular carcinomas: Quantitative analysis

    International Nuclear Information System (INIS)

    Kim, Ah Young; Choi, Byung Ihn; Kim, Tae Kyoung; Lee, Kyoung Ho; Han, Joon Koo

    1999-01-01

    To determine peak time and duration of contrast enhancement of nodular hepatocellular carcinoma (HCC) on contrast-enhancement power Doppler ultrasound (US) with Levovist by quantitative analysis. Twenty eight patients with nodular HCC were prospectively evaluated with power Doppler US by one examiner. Serial images were obtained before and after injection of 300 mg/mL US contrast agent (SH U 508 A, Levovist, Schering) with the injection rate of 0.2 mL/sec. Power Doppler signals on obtained digital images were quantified using 'Ultrasound Imaging Tool Version 1.0' (Seoul, Korea). The grade, peak time and duration of contrast enhancement of the tumors were analyzed. For nodular HCCs, mean peak enhancement time was 60 seconds after injection of Levovist (mean enhanced area 41.6 ± 28.6 %). These tumoral enhancement decreased from 90 seconds and returned to near baseline state at 5 minutes after injection of Levovist. Maximum enhanced areas (%) were variable at a range of 8-98.5% and mean maximum enhanced area was 46.4 ± 28.6%. On contrast-enhanced power Doppler US with Levovist, nodular HCCs showed peak contrast enhancement (41.6± 28.6) at 60 seconds after injection of contrast agent. This tumoral enhancement nearly disappeared at 5 minutes after injection of contrast agent.

  10. Detection of acute avascular necrosis with dynamic contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Nadel, S.N.; Richardson, W.J.; Martinez, S.; Rizk, W.S.; Malizos, K.; Debatin, J.F.

    1991-01-01

    Early detection of avascular necrosis (AVN) may allow earlier intervention and lead to improved treatment success. This paper is designed to compare standard and dynamic contrast-enhanced MR imaging in the detection of acute AVN. A previously described animal model of AVN was used. Five anesthetized dogs underwent right femoral head devascularization, including placement of a supercooling coil around the femoral neck. Within 3 hours the dogs were imaged in a 1.5-T Signa magnet. Standard T1-weighted, T2-weighted, and STIR images were obtained through both hips. A DiGrass sequence with 30 sequential 3.2-second T1-weighted images was used, and 0.2 mmol/kg gadoteridol was injected intravenously at the start of the sequence at 2 mL/sec with an automated injector. Following imaging, oxytetracycline was given intravenously. After 3 days the dogs were killed, and their femoral heads were extracted, coronally sectioned, and analyzed for fluorescence. T1-weighted, T2-weighted, and STIR sequences showed no marrow abnormalities on either the normal or the operated-on side. With contrast material injection, all normal areas and the unoperated portion the femoral neck and diaphysis enhanced markedly 4-9 seconds following the bolus

  11. Radiochromic film dosimetry of contrast-enhanced radiotherapy (CERT)

    International Nuclear Information System (INIS)

    Morris, Kevin N; Weil, Michael D; Malzbender, Rainer

    2006-01-01

    Contrast-enhanced radiotherapy (CERT) employs elevated concentrations of high-Z contrast media in targets to dramatically increase the absorbed dose of radiation relative to the surrounding tissues. However, it is difficult to measure the dose enhancement with routine clinical instruments because the photoelectrons and Auger electrons produced by the interaction of kilovoltage x-rays with the contrast agent travel extremely short distances. We have developed a technique utilizing unlaminated radiochromic film to measure the maximum dose enhancement factor attainable in solutions of contrast agent with iodine concentrations ranging from 0% to 37% (w/v). The films were also used to simultaneously measure the dose enhancement and beam attenuation through solutions containing 0%, 5% and 10% iodine (w/v). These depth-dose measurements were made in phantoms representing 3 cm targets located 0 and 4.8 cm deep in acrylic. Higher concentrations of contrast yielded greater dose enhancement and target-to-surface dose ratios, but caused more rapid attenuation of the beam as it traversed the target. The dose distribution across the entire target could be improved by employing multiple beams. These results, using concentrations of contrast that are clinically achievable by intratumoural injection, illustrate the potential of CERT for the specific delivery of high doses of radiation to targets at depth

  12. Contrast-enhanced CISS imaging of cerebellopontine angle tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Toyoda, Keiko; Hata, Yuichi; Fukuda, Yasushi; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine; Katano, Shuichi

    1999-10-01

    Our purpose of this study was to evaluate the clinical usefulness of contrast-enhanced CISS-3DFT MR imaging for the diagnosis of CP angle tumors. CISS-3DFT MR imaging is expected for screening procedure of acoustic schwannoma because of excellent spatial resolution. Recently, we discovered contrast enhancement effect on CISS sequence in spite of heavily T{sub 2}-weighted images. Fourteen patients with CP angle tumors were performed on a 1.0 T MR unit. Transaxial CISS-3DFT MRI was obtained both before and after intravenous injections of Gd-DTPA. Multiplanar reconstructions (MPRs) were performed in all cases. Contrast enhancement effect of CP angle tumors, and the relationship between tumors and the adjacent cranial nerves were evaluated. Contrast enhancement effect of the tumors was present in all cases in spite of heavily T{sub 2}-weighted images of CISS sequences. In the internal auditory canal, relationship between the tumors and the cranial nerves was demonstrated in 6 cases (6/9). In the cerebellopontine cistern, all cases were demonstrated (11/11). Contrast-enhanced CISS-3DFT MR imaging with a good contrast resolution and an excellent spatial resolution is useful for the diagnosis of CP angle tumors. (author)

  13. Adaptive radiotherapy based on contrast enhanced cone beam CT imaging

    International Nuclear Information System (INIS)

    Soevik, Aaste; Skogmo, Hege K.; Roedal, Jan; Lervaag, Christoffer; Eilertsen, Karsten; Malinen, Eirik

    2010-01-01

    Cone beam CT (CBCT) imaging has become an integral part of radiation therapy, with images typically used for offline or online patient setup corrections based on bony anatomy co-registration. Ideally, the co-registration should be based on tumor localization. However, soft tissue contrast in CBCT images may be limited. In the present work, contrast enhanced CBCT (CECBCT) images were used for tumor visualization and treatment adaptation. Material and methods. A spontaneous canine maxillary tumor was subjected to repeated cone beam CT imaging during fractionated radiotherapy (10 fractions in total). At five of the treatment fractions, CECBCT images, employing an iodinated contrast agent, were acquired, as well as pre-contrast CBCT images. The tumor was clearly visible in post-contrast minus pre-contrast subtraction images, and these contrast images were used to delineate gross tumor volumes. IMRT dose plans were subsequently generated. Four different strategies were explored: 1) fully adapted planning based on each CECBCT image series, 2) planning based on images acquired at the first treatment fraction and patient repositioning following bony anatomy co-registration, 3) as for 2), but with patient repositioning based on co-registering contrast images, and 4) a strategy with no patient repositioning or treatment adaptation. The equivalent uniform dose (EUD) and tumor control probability (TCP) calculations to estimate treatment outcome for each strategy. Results. Similar translation vectors were found when bony anatomy and contrast enhancement co-registration were compared. Strategy 1 gave EUDs closest to the prescription dose and the highest TCP. Strategies 2 and 3 gave EUDs and TCPs close to that of strategy 1, with strategy 3 being slightly better than strategy 2. Even greater benefits from strategies 1 and 3 are expected with increasing tumor movement or deformation during treatment. The non-adaptive strategy 4 was clearly inferior to all three adaptive strategies

  14. Abducens nerve enhancement demonstrated by multiplanar reconstruction of contrast-enhanced three-dimensional MRI

    International Nuclear Information System (INIS)

    Hosoya, T.; Adachi, M.; Sugai, Y.; Yamaguchi, K.; Yamaguchi, K.; Kato, T.

    2001-01-01

    We describe contrast enhancement of the cisternal portion of the abducens nerve and discuss its clinical significance. We examined 67 patients with ophthalmoplegia using contrast-enhanced 3-dimensional (3D) MRI with multiplanar reconstruction along the nerves and found 16 patients (ten men, six women), aged 10-73 years (mean 34.4 years), with contrast enhancement of the abducens nerve. Of the 36 patients who had an abducens palsy, 14 (39 %) showed contrast enhancement. In the 16 patients, 23 abducens nerves enhanced; 13 were symptomatic and 10 asymptomatic at the time. The causes were disseminated tumour (1), an inflammatory process (3), trauma (2), ischaemia (2) and autoimmune diseases (8), such as the Miller Fisher syndrome, acute ophthalmoparesis, polyneuropathy and multiple sclerosis. Abducens and/or oculomotor nerve enhancement was the only abnormality on MRI in the patients with traumatic or ischaemic neuropathy or autoimmune diseases. There were 14 patients who recovered fully within 1-6 months after treatment, and resolution of the enhancement correlated well with recovery. (orig.)

  15. Abducens nerve enhancement demonstrated by multiplanar reconstruction of contrast-enhanced three-dimensional MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hosoya, T.; Adachi, M.; Sugai, Y. [Dept. of Radiology, Yamagata University School of Medicine (Japan); Yamaguchi, K.; Yamaguchi, K. [Dept. of Ophthalmology, Yamagata University School of Medicine (Japan); Kato, T. [3. Dept. of Internal Medicine, Yamagata University School of Medicine (Japan)

    2001-04-01

    We describe contrast enhancement of the cisternal portion of the abducens nerve and discuss its clinical significance. We examined 67 patients with ophthalmoplegia using contrast-enhanced 3-dimensional (3D) MRI with multiplanar reconstruction along the nerves and found 16 patients (ten men, six women), aged 10-73 years (mean 34.4 years), with contrast enhancement of the abducens nerve. Of the 36 patients who had an abducens palsy, 14 (39 %) showed contrast enhancement. In the 16 patients, 23 abducens nerves enhanced; 13 were symptomatic and 10 asymptomatic at the time. The causes were disseminated tumour (1), an inflammatory process (3), trauma (2), ischaemia (2) and autoimmune diseases (8), such as the Miller Fisher syndrome, acute ophthalmoparesis, polyneuropathy and multiple sclerosis. Abducens and/or oculomotor nerve enhancement was the only abnormality on MRI in the patients with traumatic or ischaemic neuropathy or autoimmune diseases. There were 14 patients who recovered fully within 1-6 months after treatment, and resolution of the enhancement correlated well with recovery. (orig.)

  16. Human cerebral blood volume measurements using dynamic contrast enhancement in comparison to dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Artzi, Moran [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Liberman, Gilad; Vitinshtein, Faina; Aizenstein, Orna [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Nadav, Guy [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Faculty of Engineering, Tel Aviv (Israel); Blumenthal, Deborah T.; Bokstein, Felix [Tel Aviv Sourasky Medical Center, Neuro-Oncology Service, Tel Aviv (Israel); Bashat, Dafna Ben [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine and Sagol School of Neuroscience, Tel Aviv (Israel)

    2015-07-15

    Cerebral blood volume (CBV) is an important parameter for the assessment of brain tumors, usually obtained using dynamic susceptibility contrast (DSC) MRI. However, this method often suffers from low spatial resolution and high sensitivity to susceptibility artifacts and usually does not take into account the effect of tissue permeability. The plasma volume (v{sub p}) can also be extracted from dynamic contrast enhancement (DCE) MRI. The aim of this study was to investigate whether DCE can be used for the measurement of cerebral blood volume in place of DSC for the assessment of patients with brain tumors. Twenty-eight subjects (17 healthy subjects and 11 patients with glioblastoma) were scanned using DCE and DSC. v{sub p} and CBV values were measured and compared in different brain components in healthy subjects and in the tumor area in patients. Significant high correlations were detected between v{sub p} and CBV in healthy subjects in the different brain components; white matter, gray matter, and arteries, correlating with the known increased tissue vascularity, and within the tumor area in patients. This work proposes the use of DCE as an alternative method to DSC for the assessment of blood volume, given the advantages of its higher spatial resolution, its lower sensitivity to susceptibility artifacts, and its ability to provide additional information regarding tissue permeability. (orig.)

  17. Generalized image contrast enhancement technique based on Heinemann contrast discrimination model

    Science.gov (United States)

    Liu, Hong; Nodine, Calvin F.

    1994-03-01

    This paper presents a generalized image contrast enhancement technique which equalizes perceived brightness based on the Heinemann contrast discrimination model. This is a modified algorithm which presents an improvement over the previous study by Mokrane in its mathematically proven existence of a unique solution and in its easily tunable parameterization. The model uses a log-log representation of contrast luminosity between targets and the surround in a fixed luminosity background setting. The algorithm consists of two nonlinear gray-scale mapping functions which have seven parameters, two of which are adjustable Heinemann constants. Another parameter is the background gray level. The remaining four parameters are nonlinear functions of gray scale distribution of the image, and can be uniquely determined once the previous three are given. Tests have been carried out to examine the effectiveness of the algorithm for increasing the overall contrast of images. It can be demonstrated that the generalized algorithm provides better contrast enhancement than histogram equalization. In fact, the histogram equalization technique is a special case of the proposed mapping.

  18. Ionic and non-ionic contrast media used for contrast-enhanced computed tomography in experimental pancreatitis

    International Nuclear Information System (INIS)

    Kivisaari, L.; Nuutinen, P.; Lehtola, A.; Saari, A.; Pitkaeranta, P.; Standertskjoeld-Nordenstam, C.G.; Lempinen, M.; Schroeder, T.; Helsinki Univ. Central Hospital

    1988-01-01

    Contrast enhancement of the pancreas was studied in pigs using dynamic computed tomography in experimental oedematous and haemorrhagic/necrotizing pancreatitis during the first two minutes after injection of an intravenous bolus of non-ionic contrast medium (iohexol). The prospects of separating the two forms of the disease, known to be possible with ionic contrast media, were tested with a non-ionic contrast medium. In the oedematous form, contrast enhancement after 5 hours of the disease was significantly higher than in the haemorrhagic/necrotizing form. Contrast enhancement after 30 hours of disease tended to vary with the severity of the disease, showing that the course of oedematous pancreatitis is dynamic. Intermediate forms occur and follow-up studies are needed during the disease. A non-ionic contrast medium proved as good for separating the two forms of the disease in the early phase as were ionic contrast media. In severely ill patients, non-ionic contrast media should therefore be used. (orig.)

  19. The 'humble' bubble: Contrast-enhanced ultrasound

    International Nuclear Information System (INIS)

    Marshall, Gill; Sykes, Anne; Berry, Jonathan; Jonker, Leon

    2011-01-01

    The use of contrast-enhanced ultrasound (CEUS) is increasing within the field of medical imaging. Ultrasonic contrast agent (UCA) contain gas microbubbles similar in size to red corpuscles which provide highly reflective interfaces, enabling dynamic demonstration of echogenic streams of the contrast within the anatomical area of interest on real-time grey scale ultrasound. Longevity of the microbubbles has been improved by changing their composition. The application of CEUS in the UK continues to grow, bringing it into territories historically occupied by computerised tomography (CT) scanning and magnetic resonance imaging (MRI). Hence, the role of CEUS may be of interest to all diagnostic imaging practitioners. Here we summarise the mode of action and use of CEUS, and its role within a range of applications. The potential risks of CEUS are compared to other contrast-enhanced imaging techniques. The benefits of CEUS and its implications for diagnostic imaging practice are also covered.

  20. Contrast-enhanced MR enterography as a stand-alone tool to evaluate Crohn's disease in a paediatric population

    International Nuclear Information System (INIS)

    Spieler, B.; Hindman, N.; Levy, J.; Zabrieski, K.; Sahlein, D.; Seuss, C.; Kim, S.

    2013-01-01

    Aim: To assess the performance of contrast-enhanced T1-weighted magnetic resonance imaging (MRI) alone in the evaluation of Crohn's disease in comparison to all magnetic resonance enterography (MRE) imaging sequences together in an attempt to suggest limitation of the number of overall unenhanced sequences need for the follow-up evaluation. Materials and methods: Twenty-five paediatric patients (mean age 14.1 ± 3.7 years, male = 12, female = 13) underwent MRE at 1.5 T for evaluation of Crohn's disease. Two radiologists reviewed only contrast-enhanced T1-weighted images in consensus on the first session. Whole images including unenhanced (steady-state free precession, single-shot fast spin-echo (HASTE), fat-suppressed T2-weighted) and contrast-enhanced T1-weighted sequences were reviewed in consensus during the second session with a 1 month interval, which was used as a reference standard. The readers evaluated the presence or absence of disease in 10 bowel segments in each patient. For the abnormal bowel segments, the readers then evaluated for active versus inactive disease and for the presence or absence of abscess. Sensitivity, specificity, and overall accuracy were calculated for detecting active inflammation. Results: There were 53/250 bowel segments with active inflammation using the reference standard imaging method. The sensitivity, specificity, and accuracy for diagnosing active inflammation using contrast-enhanced images alone were 83.3%, 86.9%, and 84.9%. In five of the false-positive cases of detecting abscess from contrast-enhanced imaging alone, absence of abscesses was confirmed on the non-fat-suppressed HASTE images. Conclusion: The number of MRE sequences in paediatric Crohn's patients can be decreased while maintaining diagnostic accuracy using contrast-enhanced T1 and non-fat-suppressed HASTE images

  1. Quantitative analysis of contrast enhanced MRI of the inferior alveolar nerve in inflammatory changes of the mandible

    International Nuclear Information System (INIS)

    Gottschalk, G.; Gerber, S.; Solbach, T.; Baehren, W.; Anders, L.; Kress, B.

    2003-01-01

    Purpose: To evaluate the role of contrast enhanced MRI in quantifying signal changes of the inferior alveolar nerve following inflammatory changes of the mandible. Material and methods: 30 patients with inflammatory changes of the mandible underwent MRI of the face. Both sides of the mandible, the affected as well as the unaffected healthy side were evaluated retrospectively. Regions of interest were placed at 5 defined placed on both sides to assess signal intensity before and after intravenous application of paramagnetic contrast agent. The results of the measurements were compared between the healthy and the affected side (t-test, p [de

  2. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    International Nuclear Information System (INIS)

    Parmar, Hemant; Sitoh, Y.-Y.; Anand, Pooja; Chua, Violet; Hui, Francis

    2006-01-01

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis

  3. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Parmar, Hemant [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore) and Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada)]. E-mail: parurad@hotmail.com; Sitoh, Y.-Y. [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Anand, Pooja [Department of Neurology, National Neuroscience Institute, 11 Jalan Tan Tock Seng (Singapore); Chua, Violet [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Hui, Francis [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-04-15

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis.

  4. Adaptive multiscale processing for contrast enhancement

    Science.gov (United States)

    Laine, Andrew F.; Song, Shuwu; Fan, Jian; Huda, Walter; Honeyman, Janice C.; Steinbach, Barbara G.

    1993-07-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through overcomplete multiresolution representations. We show that efficient representations may be identified from digital mammograms within a continuum of scale space and used to enhance features of importance to mammography. Choosing analyzing functions that are well localized in both space and frequency, results in a powerful methodology for image analysis. We describe methods of contrast enhancement based on two overcomplete (redundant) multiscale representations: (1) Dyadic wavelet transform (2) (phi) -transform. Mammograms are reconstructed from transform coefficients modified at one or more levels by non-linear, logarithmic and constant scale-space weight functions. Multiscale edges identified within distinct levels of transform space provide a local support for enhancement throughout each decomposition. We demonstrate that features extracted from wavelet spaces can provide an adaptive mechanism for accomplishing local contrast enhancement. We suggest that multiscale detection and local enhancement of singularities may be effectively employed for the visualization of breast pathology without excessive noise amplification.

  5. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography; Diagnostico da esteatose hepatica pela tomografia computadorizada de abdome com meio de contraste intravenoso

    Energy Technology Data Exchange (ETDEWEB)

    Monjardim, Rodrigo da Fonseca; Costa, Danilo Manuel Cerqueira; Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Santos, Jaime de Vargas Conde dos; Atzingen, Augusto Castelli Von; Shigueoka, David Carlos; D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Universidade Federal de Sao Paulo (EPM/UNIFESP), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem

    2013-05-15

    Objective: to evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and methods: in the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 Multiplication-Sign (0.75 Multiplication-Sign P + 0.25 Multiplication-Sign A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results: the simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion: The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity. (author)

  6. Fibroadenomas of the breast: histopathological/dynamic contrast-enhanced MR correlation

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, R. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Garnier, C. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Meingan, P. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Zemoura, L. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Lucidarme, O. [Dept. of Radiology, Hopital Salpetriere, 75 - Paris (France); Guinebretiere, J.M. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Tardivon, A.A. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Arriagada, R. [Breast Cancer Study Group, Inst. Gustave Roussy, 94 - Villejuif, (France)

    1995-12-31

    A total of 22 women with fibroadenomas had preoperative dynamic MR study (T1-weighted images every 47 s after injection of Gd-DOTA). Their age, hormonal status, breast MR studies and histopathological slides were retrospectively reviewed. Eleven pre- (n = 2) or post-menopausal (n = 9) women showed no early contrast enhancement. The absence of early contrast enhancement correlated with hyalin stromal component. Eleven pre- (n = 7) or post-menopausal (n = 4) women showed focal (n = 9) or diffuse (n = 2) early contrast enhancement. Early focal contrast enhancement correlated with myxoid (n = 9), mixed hyalin/myxoid (n = 1) or hyalin (n = 1) fibroadenomas. Early diffuse contrast enhancement of the breast correlated with myxoid (n = 1) or hyalin (n = 1) stromal component associated with proliferative fibrocystic disease of the breast parenchyma. The presence of contrast enhancement correlated with myxoid fibroadenomas, whereas absence of contrast enhancement correlated with hyalin fibroadenomas. As hyalin fibroadenomas occurs in post-menopausal women, the diagnostic accuracy of dynamic MRI may be improved in this age group. (orig.)

  7. Fibroadenomas of the breast: histopathological/dynamic contrast-enhanced MR correlation

    International Nuclear Information System (INIS)

    Gilles, R.; Garnier, C.; Meingan, P.; Zemoura, L.; Lucidarme, O.; Guinebretiere, J.M.; Tardivon, A.A.; Arriagada, R.

    1995-01-01

    A total of 22 women with fibroadenomas had preoperative dynamic MR study (T1-weighted images every 47 s after injection of Gd-DOTA). Their age, hormonal status, breast MR studies and histopathological slides were retrospectively reviewed. Eleven pre- (n = 2) or post-menopausal (n = 9) women showed no early contrast enhancement. The absence of early contrast enhancement correlated with hyalin stromal component. Eleven pre- (n = 7) or post-menopausal (n = 4) women showed focal (n = 9) or diffuse (n = 2) early contrast enhancement. Early focal contrast enhancement correlated with myxoid (n = 9), mixed hyalin/myxoid (n 1) or hyalin (n = 1) fibroadenomas. Early diffuse contrast enhancement of the breast correlated with myxoid (n = 1) or hyalin (n = 1) stromal component associated with proliferative fibrocystic disease of the breast parenchyma. The presence of contrast enhancement correlated with myxoid fibroadenomas, whereas absence of contrast enhancement correlated with hyalin fibroadenomas. As hyalin fibroadenomas occurs in post-menopausal women, the diagnostic accuracy of dynamic MRI may be improved in this age group. (orig.)

  8. Newly Diagnosed Breast Cancer: Comparison of Contrast-enhanced Spectral Mammography and Breast MR Imaging in the Evaluation of Extent of Disease.

    Science.gov (United States)

    Lee-Felker, Stephanie A; Tekchandani, Leena; Thomas, Mariam; Gupta, Esha; Andrews-Tang, Denise; Roth, Antoinette; Sayre, James; Rahbar, Guita

    2017-11-01

    Purpose To compare the diagnostic performances of contrast material-enhanced spectral mammography and breast magnetic resonance (MR) imaging in the detection of index and secondary cancers in women with newly diagnosed breast cancer by using histologic or imaging follow-up as the standard of reference. Materials and Methods This institutional review board-approved, HIPAA-compliant, retrospective study included 52 women who underwent breast MR imaging and contrast-enhanced spectral mammography for newly diagnosed unilateral breast cancer between March 2014 and October 2015. Of those 52 patients, 46 were referred for contrast-enhanced spectral mammography and targeted ultrasonography because they had additional suspicious lesions at MR imaging. In six of the 52 patients, breast cancer had been diagnosed at an outside institution. These patients were referred for contrast-enhanced spectral mammography and targeted US as part of diagnostic imaging. Images from contrast-enhanced spectral mammography were analyzed by two fellowship-trained breast imagers with 2.5 years of experience with contrast-enhanced spectral mammography. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated for both imaging modalities and compared by using the Bennett statistic. Results Fifty-two women with 120 breast lesions were included for analysis (mean age, 50 years; range, 29-73 years). Contrast-enhanced spectral mammography had similar sensitivity to MR imaging (94% [66 of 70 lesions] vs 99% [69 of 70 lesions]), a significantly higher PPV than MR imaging (93% [66 of 71 lesions] vs 60% [69 of 115 lesions]), and fewer false-positive findings than MR imaging (five vs 45) (P contrast-enhanced spectral mammography depicted 11 of the 11 secondary cancers (100%) and MR imaging depicted 10 (91%). Conclusion Contrast-enhanced spectral mammography is potentially as sensitive as MR imaging in the evaluation of extent of disease in newly diagnosed

  9. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fukukura, Yoshihiko, E-mail: fukukura@m.kufm.kagoshima-u.ac.jp [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Takumi, Koji [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Higashi, Michiyo [Department of Human Pathology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Shinchi, Hiroyuki [Department of Surgical Oncology and Digestive Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan)

    2014-04-15

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival.

  10. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    International Nuclear Information System (INIS)

    Fukukura, Yoshihiko; Takumi, Koji; Higashi, Michiyo; Shinchi, Hiroyuki; Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro

    2014-01-01

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival

  11. Contrast-enhanced computed tomographic colonography in the follow-up of colorectal cancer patients: a feasibility study

    International Nuclear Information System (INIS)

    Laghi, Andrea; Iannaccone, Riccardo; Carbone, Iacopo; Piacentini, Francesca; Passariello, Roberto; Bria, Emilio; Trasatti, Luciana; Lauro, Salvatore; Vecchione, Aldo

    2003-01-01

    The aim of our study was to assess whether contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up program of colorectal cancer patients. Thirty-five patients, surgically treated for colorectal cancer, underwent a follow-up program that included physical examination, carcinoembryonic antigen serum assay, conventional colonoscopy, liver ultrasonography, and chest X-ray. For these patients, we added a yearly contrast-enhanced CT colonography. All CT examinations were performed with a high-resolution protocol using a multidetector spiral CT scanner (Siemens, Erlangen, Germany) prior to and after the administration of 130 ml of i.v. contrast material. Images were directly analyzed on a dedicated workstation by two radiologists to determine colonic evaluation, visualization of colonic anastomosis, presence of polyps, and extra-colonic findings. Colonic evaluation was judged as optimal in 91.7% of all colonic segments. All mechanical surgical anastomoses were visualized with CT colonography. There was no evidence of anastomotic recurrence. Seven polyps were detected in five different patients with CT colonography, with two false-positive and no false-negative examinations. Three liver metastases and two basal pulmonary nodules were also identified. Contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up of patients operated on for colorectal cancer. (orig.)

  12. EFFECT OF SEDATION ON CONTRAST-ENHANCED ULTRASONOGRAPHY OF THE SPLEEN IN HEALTHY DOGS.

    Science.gov (United States)

    Rossi, Federica; Fina, Caroline; Stock, Emmelie; Vanderperren, Katrien; Duchateau, Luc; Saunders, Jimmy H

    2016-05-01

    Contrast-enhanced ultrasound of the spleen enables the dynamic assessment of the perfusion of this organ, however, both subjective and quantitative evaluation can be strongly influenced by sedative agent administration. The purpose of this prospective, experimental study was to test effects of two sedative agents on splenic perfusion during contrast-enhanced ultrasound of the spleen in a sample of healthy dogs. Contrast-enhanced ultrasound of the spleen was repeated in six healthy Beagles following a cross-over study design comparing three protocols: awake, butorphanol 0.2 mg/Kg intramuscular (IM), and dexmedetomidine 500 μg/m(2) IM. After intravenous injection of a phospholipid stabilized sulfur hexafluoride microbubble solution (SonoVue®, Bracco Imaging, Milano, Italy), the enhancement intensity and perfusion pattern of the splenic parenchyma were assessed and perfusion parameters were calculated. Normal spleen was slightly heterogeneous in the early phase, but the parenchyma was homogeneous at a later phase. Sedation with butorphanol did not modify perfusion of the spleen. Dexmedetomidine significantly reduced splenic enhancement, providing diffuse parenchymal hypoechogenicity during the entire examination. Measured parameters were significantly modified, with increased arrival time (AT; (dogs. Short-term and diffuse heterogeneity of the spleen in the early venous phase was determined to be a normal finding. © 2016 American College of Veterinary Radiology.

  13. Dynamics of contrast enhancement in MR imaging and power Doppler ultrasonography of solid breast lesions

    International Nuclear Information System (INIS)

    Reinikainen, H.; Paeaekkoe, E.; Suramo, I.; Paeivaensalo, M.; Rissanen, T.

    2002-01-01

    Purpose: To evaluate the dynamics of contrast enhancement in solid breast lesions at contrast-enhanced MR imaging and power Doppler ultrasonography (US) and to compare the methods to histology and to each other. Material and Methods: Forty breast lesions were prospectively examined with dynamic MR and power Doppler US. Time-signal intensity curves of enhancement were obtained for both methods. The shape of the curve was analyzed to be benign, indeterminate or malignant. The curves were also analyzed quantitatively by calculating the slope of the curve and the area under the curve (both methods), relative enhancement (MR), and time to peak (US). The lesions were divided into malignant lesions, fibroadenomas, and other benign lesions. The results were compared to histology. Results: In the subjective analysis of the MR curve in differentiating between benign and malignant lesions the accuracy was 90%. The MR curve also enabled differentiation between fibroadenomas and malignancies. The accuracy of the US curve was 38%. Quantitatively, statistically significant differences were found using all the MR variables, except between malignancies and fibroadenomas. Using the US variables, no significant difference was found between the groups. Conclusion: The dynamics of contrast-enhanced MR were reliable in the differential diagnosis of solid breast lesions, but contrast-enhanced power Doppler US was of limited value

  14. Noninvasive evaluation of active lower gastrointestinal bleeding: comparison between contrast-enhanced MDCT and 99mTc-labeled RBC scintigraphy.

    Science.gov (United States)

    Zink, Stephen I; Ohki, Stephen K; Stein, Barry; Zambuto, Domenic A; Rosenberg, Ronald J; Choi, Jenny J; Tubbs, Daniel S

    2008-10-01

    The purpose of our study was to compare contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning for the evaluation of active lower gastrointestinal bleeding. Over 17 months, 55 patients (32 men, 23 women; age range, 21-92 years) were evaluated prospectively with contrast-enhanced MDCT using 100 mL of iopromide 300 mg I/mL. Technetium-99m-labeled RBC scans were obtained on 41 of 55 patients and select patients underwent angiography for attempted embolization. Each imaging technique was reviewed in a blinded fashion for sensitivity for detection of active bleeding as well as the active lower gastrointestinal bleeding location. Findings were positive on both examinations in eight patients and negative on both examinations in 20 patients. Findings were positive on contrast-enhanced MDCT and negative on (99m)Tc-labeled RBC in two patients; findings were negative on contrast-enhanced MDCT and positive on (99m)Tc-labeled RBC in 11 patients. Statistics showed significant disagreement, with simple agreement = 68.3%, kappa = 0.341, and p = 0.014. Sixteen of 60 (26.7%) contrast-enhanced MDCT scans were positive prospectively, with all accurately localizing the site of bleeding and identification of the underlying lesion in eight of 16 (50%). Nineteen of 41 (46.3%) (99m)Tc-labeled RBC scans were positive. Eighteen of 41 matched patients went on to angiography. In four of these 18 (22.2%) patients, the site of bleeding was confirmed by angiography, but in 14 of 18 (77.8%), the findings were negative. Contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning show significant disagreement for evaluation of active lower gastrointestinal bleeding. Contrast-enhanced MDCT appears effective for detection and localization in cases of active lower gastrointestinal bleeding in which hemorrhage is active at the time of CT.

  15. Differences in perfusion parameters between upper and lower lumbar vertebral segments with dynamic contrast-enhanced MRI (DCE MRI)

    International Nuclear Information System (INIS)

    Savvopoulou, Vasiliki; Vlahos, Lampros; Moulopoulos, Lia Angela; Maris, Thomas G.

    2008-01-01

    To investigate the influence of age, sex and spinal level on perfusion parameters of normal lumbar bone marrow with dynamic contrast-enhanced MRI (DCE MRI). Sixty-seven subjects referred for evaluation of low back pain or sciatica underwent DCE MRI of the lumbar spine. After subtraction of dynamic images, a region of interest (ROI) was placed on each lumbar vertebral body of all subjects, and time intensity curves were generated. Consequently, perfusion parameters were calculated. Statistical analysis was performed to search for perfusion differences among lumbar vertebrae and in relation to age and sex. Upper (L1, L2) and lower (L3, L4, L5) vertebrae showed significant differences in perfusion parameters (p<0.05). Vertebrae of subjects younger than 50 years showed significantly higher perfusion compared to vertebrae of older ones (p<0.05). Vertebrae of females demonstrated significantly increased perfusion compared to those of males of corresponding age (p<0.05). All perfusion parameters, except for washout (WOUT), showed a mild linear correlation with age. Time to maximum slope (TMSP) and time to peak (TTPK) showed the same correlation with sex (0.22< r<0.32, p<0.05). Our results indicate increased perfusion of the upper compared to the lower lumbar spine, of younger compared to older subjects and of females compared to males. (orig.)

  16. Differences in perfusion parameters between upper and lower lumbar vertebral segments with dynamic contrast-enhanced MRI (DCE MRI)

    Energy Technology Data Exchange (ETDEWEB)

    Savvopoulou, Vasiliki; Vlahos, Lampros; Moulopoulos, Lia Angela [University of Athens, Areteion Hospital, Department of Radiology, Medical School, Athens (Greece); Maris, Thomas G. [University of Crete, Deparment of Medical Physics, Faculty of Medicine, Heraklion (Greece)

    2008-09-15

    To investigate the influence of age, sex and spinal level on perfusion parameters of normal lumbar bone marrow with dynamic contrast-enhanced MRI (DCE MRI). Sixty-seven subjects referred for evaluation of low back pain or sciatica underwent DCE MRI of the lumbar spine. After subtraction of dynamic images, a region of interest (ROI) was placed on each lumbar vertebral body of all subjects, and time intensity curves were generated. Consequently, perfusion parameters were calculated. Statistical analysis was performed to search for perfusion differences among lumbar vertebrae and in relation to age and sex. Upper (L1, L2) and lower (L3, L4, L5) vertebrae showed significant differences in perfusion parameters (p<0.05). Vertebrae of subjects younger than 50 years showed significantly higher perfusion compared to vertebrae of older ones (p<0.05). Vertebrae of females demonstrated significantly increased perfusion compared to those of males of corresponding age (p<0.05). All perfusion parameters, except for washout (WOUT), showed a mild linear correlation with age. Time to maximum slope (TMSP) and time to peak (TTPK) showed the same correlation with sex (0.22subjects and of females compared to males. (orig.)

  17. Challenges in contrast-enhanced spectral mammography interpretation: artefacts lexicon.

    Science.gov (United States)

    Yagil, Y; Shalmon, A; Rundstein, A; Servadio, Y; Halshtok, O; Gotlieb, M; Sklair-Levy, M

    2016-05-01

    To review and describe commonly encountered artefacts in contrast-enhanced spectral mammography (CESM). This retrospective study included 200 women who underwent CESM examinations for screening and diagnostic purposes. Analysis was performed on the image data sets of these women, comprising of a total of 774 subtracted images. Images were reviewed with focus on the presence of four artefacts: rim ("breast within breast"), ripple (black and white lines), axillary line, and skin-line enhancement (skin-line highlighting). Statistical cross-correlation and association with acquisition parameters (tube current, tube voltage, compression force, breast thickness, paddle size) was compared using Fisher's exact test and t-test. The rim artefact was highly common (97-99%) in every projection. The ripple artefact was increasingly more common on the oblique projections (80-82%) and found to be associated with higher breast thickness values. The axillary line artefact was detected only on oblique projections (63%) and associated with the use of a small compression paddle. The skin-line enhancement artefact was seen in 19-46% of projections. None of the artefacts interfered with image interpretation. Two main artefacts commonly seen on CESM are rim and ripple artefacts. They do not hamper with image interpretation. It is important to be aware of them and prevent misinterpretation of these artefacts as real breast pathology. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. Post-traumatic contrast enhancing brain lesion

    International Nuclear Information System (INIS)

    Kim, Dae Jung; Kim, Hyun Sook; Jeong, Min Sun; Kim, Deok Ryeong; Cho, Young Kwon; Choi, Yun Sun

    2014-01-01

    Only a few studies have been reported on the MR contrast enhancement and the apparent diffusion coefficient (ADC) findings of the post-traumatic lesion of the brain. We report a case of the venous ischemia in the left frontal lobe observed in the MRI obtained one day after the incidence of trauma. Considering the presented slight increase in the ADC, the vasogenic edema was thought to be the major mechanism of the venous ischemia and excitotoxic injury. In spite of a slight increase in the ADC, the hyperintensity in the diffusion weighted imaging and contrast-enhanced areas eventually changed into hemorrhagic lesions.

  19. Post-traumatic contrast enhancing brain lesion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Jung; Kim, Hyun Sook; Jeong, Min Sun; Kim, Deok Ryeong; Cho, Young Kwon; Choi, Yun Sun [Eulji Hospital, Eulji University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    Only a few studies have been reported on the MR contrast enhancement and the apparent diffusion coefficient (ADC) findings of the post-traumatic lesion of the brain. We report a case of the venous ischemia in the left frontal lobe observed in the MRI obtained one day after the incidence of trauma. Considering the presented slight increase in the ADC, the vasogenic edema was thought to be the major mechanism of the venous ischemia and excitotoxic injury. In spite of a slight increase in the ADC, the hyperintensity in the diffusion weighted imaging and contrast-enhanced areas eventually changed into hemorrhagic lesions.

  20. Contrast-enhanced endoscopic ultrasonography in digestive diseases.

    Science.gov (United States)

    Hirooka, Yoshiki; Itoh, Akihiro; Kawashima, Hiroki; Ohno, Eizaburo; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Sugimoto, Hiroyuki; Sumi, Hajime; Hayashi, Daijiro; Ohmiya, Naoki; Miyahara, Ryoji; Nakamura, Masanao; Funasaka, Kohei; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi

    2012-10-01

    Contrast-enhanced endoscopic ultrasonography (CE-EUS) was introduced in the early 1990s. The concept of the injection of carbon dioxide microbubbles into the hepatic artery as a contrast material (enhanced ultrasonography) led to "endoscopic ultrasonographic angiography". After the arrival of the first-generation contrast agent, high-frequency (12 MHz) EUS brought about the enhancement of EUS images in the diagnosis of pancreatico-biliary diseases, upper gastrointestinal (GI) cancer, and submucosal tumors. The electronic scanning endosonoscope with both radial and linear probes enabled the use of high-end ultrasound machines and depicted the enhancement of both color/power Doppler flow-based imaging and harmonic-based imaging using second-generation contrast agents. Many reports have described the usefulness of the differential diagnosis of pancreatic diseases and other abdominal lesions. Quantitative evaluation of CE-EUS images was an objective method of diagnosis using the time-intensity curve (TIC), but it was limited to the region of interest. Recently developed Inflow Time Mapping™ can be generated from stored clips and used to display the pattern of signal enhancement with time after injection, offering temporal difference of contrast agents and improved tumor characterization. On the other hand, three-dimensional CE-EUS images added new information to the literature, but lacked positional information. Three-dimensional CE-EUS with accurate positional information is awaited. To date, most reports have been related to pancreatic lesions or lymph nodes. Hemodynamic analysis might be of use for diseases in other organs: upper GI cancer diagnosis, submucosal tumors, and biliary disorders, and it might also provide functional information. Studies of CE-EUS in diseases in many other organs will increase in the near future.

  1. Carcinoma of the uterine cervix. High-resolution turbo spin-echo MR imaging with contrast-enhanced dynamic scanning and T2-weighting

    International Nuclear Information System (INIS)

    Abe, Y.; Yamashita, Y.; Namimoto, T.; Takahashi, M.; Katabuchi, H.; Tanaka, N.; Okamura, H.

    1998-01-01

    Purpose: To compare high-resolution contrast-enhanced (Gd-DTPA) dynamic MR imaging with T2-weighted turbo spin-echo (TSE) imaging in the evaluation of uterine cervical carcinoma. Material and Methods: Thirty-two patients with cervical carcinoma underwent MR imaging on a 1.5 T superconductive unit to have the extension of the disease assessed before treatment. A phased-array coil was used in all patients. In 25 patients, surgical confirmation of the diagnosis was obtained after imaging. Radiation therapy was selected for the remaining 7 patients with advanced carcinoma. Qualitative and quantitative image analyses were also performed. Results: The cervical carcinomas showed maximum contrast in the cervical stroma and myometrium in the early dynamic phase. The tumor/cervical-stroma contrast in the early dynamic phase obtained with the T1-weighted TSE technique (contrast-to-noise ratio 22.6) was significantly higher than that obtained in T2-weighted TSE imaging (contrast-to-noise ratio 4.3). In the evaluation of parametrial invasion, the accuracy of T2-weighted imaging was 71.8% and contrast-enhanced dynamic imaging 81.2%. Conclusion: High-resolution contrast-enhanced (Gd-DTPA) dynamic MR imaging in cervical cancer offers improved tumor/cervical-stroma contrast and provides useful information on parametrial invasion. (orig.)

  2. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  3. Contrast enhancement of mail piece images

    Science.gov (United States)

    Shin, Yong-Chul; Sridhar, Ramalingam; Demjanenko, Victor; Palumbo, Paul W.; Hull, Jonathan J.

    1992-08-01

    A New approach to contrast enhancement of mail piece images is presented. The contrast enhancement is used as a preprocessing step in the real-time address block location (RT-ABL) system. The RT-ABL system processes a stream of mail piece images and locates destination address blocks. Most of the mail pieces (classified into letters) show high contrast between background and foreground. As an extreme case, however, the seasonal greeting cards usually use colored envelopes which results in reduced contrast osured by an error rate by using a linear distributed associative memory (DAM). The DAM is trained to recognize the spectra of three classes of images: with high, medium, and low OCR error rates. The DAM is not forced to make a classification every time. It is allowed to reject as unknown a spectrum presented that does not closely resemble any that has been stored in the DAM. The DAM was fairly accurate with noisy images but conservative (i.e., rejected several text images as unknowns) when there was little ground and foreground degradations without affecting the nondegraded images. This approach provides local enhancement which adapts to local features. In order to simplify the computation of A and (sigma) , dynamic programming technique is used. Implementation details, performance, and the results on test images are presented in this paper.

  4. Contrast Enhanced Spectral Mammography: A Review.

    Science.gov (United States)

    Patel, Bhavika K; Lobbes, M B I; Lewin, John

    2018-02-01

    Contrast-enhanced spectral mammography (CESM) provides low-energy 2D mammographic images comparable to standard digital mammography and a post-contrast recombined image to assess tumor neovascularity similar to magnetic resonance imaging (MRI). The utilization of CESM in the United States is currently low but could increase rapidly given many potential indications for clinical use. This article discusses historical background and literature review of indications and diagnostic accuracy of CESM to date. CESM is a growing technique for breast cancer detection and diagnosis that has levels of sensitivity and specificity on par with contrast-enhanced breast MRI. Because of its similar performance and ease of implementation, CESM is being adopted for multiple indications previously reserved for MRI, such as problem-solving, disease extent in newly diagnosed patients, and evaluating the treatment response of neoadjuvant chemotherapy. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Generalized image contrast enhancement technique based on the Heinemann contrast discrimination model

    Science.gov (United States)

    Liu, Hong; Nodine, Calvin F.

    1996-07-01

    This paper presents a generalized image contrast enhancement technique, which equalizes the perceived brightness distribution based on the Heinemann contrast discrimination model. It is based on the mathematically proven existence of a unique solution to a nonlinear equation, and is formulated with easily tunable parameters. The model uses a two-step log-log representation of luminance contrast between targets and surround in a luminous background setting. The algorithm consists of two nonlinear gray scale mapping functions that have seven parameters, two of which are adjustable Heinemann constants. Another parameter is the background gray level. The remaining four parameters are nonlinear functions of the gray-level distribution of the given image, and can be uniquely determined once the previous three are set. Tests have been carried out to demonstrate the effectiveness of the algorithm for increasing the overall contrast of radiology images. The traditional histogram equalization can be reinterpreted as an image enhancement technique based on the knowledge of human contrast perception. In fact, it is a special case of the proposed algorithm.

  6. Complex cystic renal masses: characterization with contrast-enhanced US.

    Science.gov (United States)

    Ascenti, Giorgio; Mazziotti, Silvio; Zimbaro, Giovanni; Settineri, Nicola; Magno, Carlo; Melloni, Darwin; Caruso, Rosario; Scribano, Emanuele

    2007-04-01

    To prospectively compare contrast material-enhanced ultrasonography (US) with computed tomography (CT) in the classification of complex cystic renal masses with the Bosniak system. Ethics committee approval and written informed consent were obtained. Forty patients (17 women, 23 men; age range, 31-77 years) with 44 complex cystic renal masses detected with conventional US were prospectively examined by using second-harmonic US with a second-generation contrast agent and multiphasic helical CT. Thirty-six patients had one lesion, and four patients had two lesions. Surgical resection in nine patients and imaging follow-up in 31 patients were used to determine the outcome. On contrast-enhanced US images, masses were classified as Bosniak category II (n = 18), IIF (ie, lesions were classified as category II and follow-up was needed) (n = 16), III (n = 7), or IV (n = 3) lesions. On CT images, masses were classified as Bosniak category II (n = 24), IIF (n = 10), III (n = 7), or IV (n = 3) lesions. Interobserver agreement was high (kappa = 0.86, P < .001) for classification with US. Complete concordance between the readers was found for classification with CT. Complete concordance between contrast-enhanced US and CT was observed in the differentiation of surgical and nonsurgical complex cysts. Complete concordance among the three readers in the assessment of vascularity with contrast-enhanced US was found. Interobserver agreement in the evaluation of enhancement on CT images was high (kappa = 0.88, P < .001). Concordance between contrast-enhanced US and CT in the evaluation of vascularization was high (kappa = 0.77, P < .001). The study data suggest that contrast-enhanced second-harmonic US is appropriate for renal cyst classification with the Bosniak system.

  7. Sentinel node detection in melanomas using contrast-enhanced ultrasound

    DEFF Research Database (Denmark)

    Nielsen, K. Rue; Klyver, H.; Chakera, A. Hougaard

    2009-01-01

    in humans. PURPOSE: To investigate the possible use of CEUS in detecting SN in patients with malignant melanomas (MM), and to improve the method by using different concentrations of contrast agent and various positions of the extremity. MATERIAL AND METHODS: Ten patients with MM on an extremity and one...... healthy volunteer were included. One milliliter of a contrast agent (Sonovue; Bracco, Milan, Italy) was injected subcutaneously on both sides of the scar from the excised tumor. Contrast-enhanced lymph channels and lymph nodes (LNs) were searched for using low-mechanical-index CEUS and by stimulated...... tissue damage, as the contrast agent was not registered for subcutaneous administration. RESULTS: In one patient, two contrast-enhanced inguinal LNs were visualized by CEUS, corresponding to two inguinal SNs found by scintigraphic imaging. No contrast-enhanced lymph channels or LNs were visualized in any...

  8. Contrast-Enhanced Ultrasonography of Hepatocellular Carcinoma After Chemoembolisation Using Drug-Eluting Beads: A Pilot Study Focused on Sustained Tumor Necrosis

    International Nuclear Information System (INIS)

    Moschouris, Hippocrates; Malagari, Katerina; Papadaki, Marina Georgiou; Kornezos, Ioannis; Matsaidonis, Dimitrios

    2010-01-01

    The purpose of this study was to assess the use of contrast-enhanced ultrasonography (CEUS) and the sustained antitumor effect of drug-eluting beads used for transarterial chemoembolisation (TACE) of unresectable hepatocellular carcinoma (HCC). Ten patients with solitary, unresectable HCC underwent CEUS before, 2 days after, and 35 to 40 days after TACE using a standard dose (4 ml) of drug-eluting beads (DC Beads; Biocompatibles, Surrey, UK) preloaded with doxorubicin (25 mg doxorubicin/ml hydrated beads). For CEUS, a second-generation contrast agent (SonoVue, Bracco, Milan, Italy) and a low mechanical-index technique were used. A part of the tumor was characterized as necrotic if it showed complete lack of enhancement. The percentage of necrosis was calculated at the sonographic section that depicted the largest diameter of the tumor. Differences in the extent of early (2 days after TACE) and delayed (35 to 40 days after TACE) necrosis were quantitatively and subjectively assessed. Early post-TACE tumor necrosis ranged from 21% to 70% (mean 43.5% ± 19%). There was a statistically significant (p = 0.0012, paired Student t test) higher percentage of delayed tumor necrosis, which ranged from 24% to 88% (mean 52.3% ± 20.3%). Subjective evaluation showed a delayed obvious increase of the necrotic areas in 5 patients. In 2 patients, tumor vessels that initially remained patent disappeared on the delayed follow-up. A part of tumor necrosis after chemoembolisation of HCC with DEB seems to take place later than 2 days after TACE. CEUS may provide evidence for the sustained antitumor effect of DEB-TACE. Nevertheless, the ideal time for the imaging evaluation of tumor response remains to be defined.

  9. Use of subvoxel registration and subtraction to improve demonstration of contrast enhancement in MRI of the brain

    International Nuclear Information System (INIS)

    Curati, W.L.; Williams, E.J.; Oatridge, A.; Hajnal, J.V.; Saeed, N.; Bydder, G.M.

    1996-01-01

    To assess the potential of registration of images before and after contrast medium for improving the demonstration of contrast enhancement, we compared conventional 2 D T 1-weighted spin-echo images with precisely registered 3 D volume images and subtraction images derived from them in 2 normal subjects and 30 patients with a variety of brain disease. The volume images were registered to subvoxel accuracy using a rigid body translation and rotation, sinc interpolation and a least-squares fit; subtraction images were obtained from these. Normal contrast enhancement was demonstrated better with positionally registered volume and subtraction images than with conventional images in the meninges, ependyma, diploic veins, scalp, skin, orbit and sinuses. Abnormal enhancement was seen better in meningeal disease, multiple sclerosis and tumours as well as on follow-up studies. Subvoxel registration of images before and after contrast medium may be of considerable value in the recognition of contrast enhancement where there are small changes, or where the changes affect tissues with high or low baseline signal values. The technique also appears likely to be of value in demonstrating contrast enhancement in tissues at inferfaces and at other areas of complex anatomy, and in follow-up studies. (orig.). With 4 figs., 4 tabs

  10. Contrast enhanced CT-scans are not comparable to non-enhanced scans in emphysema quantification

    International Nuclear Information System (INIS)

    Heussel, C.P.; Kappes, J.; Hantusch, R.; Hartlieb, S.; Weinheimer, O.; Kauczor, H.-U.; Eberhardt, R.

    2010-01-01

    Systemic, interventional and surgical treatments have gone new ways in treatment of emphysema. For longitudinal therapy monitoring and as end-points for clinical trials, quantification of the disease is necessary. Sensitive, easy to measure, as well as stable and reproducible parameters have to be characterized. One parameter that might affect emphysema quantification is IV contrast enhancement, which might also be indicated. Whether or not the contrast enhanced scan is also suited for emphysema quantification or an additional scan is necessary, a retrospective analysis of 12 adult patients undergoing clinically indicated both, a non-enhanced and enhanced thin section MSCT within a week (median 0 days, range 0-4 days) was done. The in-house YACTA software was used for automatic quantification of lung and emphysema volume, emphysema index, mean lung density, and 5th, 10th, 15th percentile. After IV contrast administration, the median CT derived lung volume decreased mild by 1.1%, while median emphysema volume decreased by relevant 11%. This results in a decrease of median emphysema index by 9%. The median lung density (15th percentile) increased after contrast application by 18 HU (9 HU). CT quantification delivers emphysema values that are clearly affected by IV contrast application. The detected changes after contrast application show the results of higher density in the lung parenchyma. Therefore the amount of quantified emphysema is reduced and the lung density increased after contrast enhancement. In longitudinal analyses, non-enhanced scans should be the reference, while enhanced scans cannot be used.

  11. A wide variety of dynamic contrast-enhanced MR appearances of breast cancer: Pathologic correlation study

    International Nuclear Information System (INIS)

    Onishi, Masayuki; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi

    2008-01-01

    Purpose: The aim of this study was to elucidate the characteristic magnetic resonance (MR) appearance of breast cancers, as well as, its variations and to investigate the pathology providing different patterns of dynamic-MR appearances. Materials and methods: Fifty-two women with cancer underwent mastectomy (52 tumors resected) and had MR imaging at our institution between April 2001 and March 2004. MR images of T1WI, T2WI, dynamic-MRI and contrast-enhanced T1WI were obtained and evaluated. Dynamic-MR images were correlated with pathological findings. Results: Common MR appearance of breast cancer was a focal mass either with irregular or spiculated margins with similar signal intensity on T1WI as and similar to higher signal intensity on T2WI compared to the normal mammary gland. On static contrast-enhanced T1WI, apparent enhancement was typically observed. On dynamic MRI, tumor-rim-enhancement on an early phase image and washout enhancement pattern on dynamic images, both characteristic for breast cancer, were observed, however, the prevalence of them was relatively low, which could be explained by the variation of histopathology among breast cancer nodules. Conclusion: In diagnosing breast masses on MRI, as well as the common and characteristic findings of breast cancer, the variations of MR findings and their underlying histopathology should also be considered

  12. Contrast enhancement by lipid-based MRI contrast agents in mouse atherosclerotic plaques; a longitudinal study

    NARCIS (Netherlands)

    den Adel, Brigit; van der Graaf, Linda M.; Que, Ivo; Strijkers, Gustav J.; Löwik, Clemens W.; Poelmann, Robert E.; van der Weerd, Louise

    2013-01-01

    The use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of two differently sized gadolinium-based contrast agents to enhance atherosclerotic plaques in ApoE(-/-) mice was evaluated with MRI. We

  13. Diagnostic Accuracy of Detecting Hashimoto's Thyroiditis in Thyroid Cancer Patients Who Underwent Thyroid Surgery: Comparison of Ultrasonography, Positron Emission Tomography/CT, Contrast Enhanced CT, and Anti-Thyroid Antibody

    International Nuclear Information System (INIS)

    Kim, Young Gyun; Lee, Tae Hyun; Park, Dong Hee; Nam, Sang Been

    2012-01-01

    To compare the diagnostic accuracy of ultrasonography (US), F18-fluorodeoxyglucose positron emission tomography/CT (PET/CT), contrast enhanced CT (CECT), serum anti-thyroid antibody for detecting Hashimoto's thyroiditis in thyroid cancer patients who underwent neck surgery. A total of 150 patients with suspicious for thyroid cancer, who had previously undergone US guided needle aspiration of thyroid, were evaluated with the use of US, PET/CT, CECT and serum anti-thyroid antibody. The four studies were performed within two months before neck surgery. Hashimoto's thyroiditis was confirmed by histopathological results. The diagnostic accuracy of US, PET/CT, CECT and serum anti-thyroid antibody were calculated statistically. Hashimoto's thyroiditis was diagnosed in 51 out of the 150 patients, following neck surgery. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of US were 76.5%, 92.9%, 84.8%, 88.5%, and 87.3%, respectively. The corresponding values of PET/CT were 37.3%, 96.0%, 82.6%, 74.8%, and 76.0%, and CECT were 62.7%, 89.9%, 76.2%, 82.4%, and 80.7%, and serum anti-thyroid antibody level were 90.2%, 93.9%, 88.5%, 94.9%, and 92.7%, respectively. McNemar test revealed significant difference among PET/CT and others, but no significant differences among US, CECT and serum anti-thyroid antibody. Overall, serum anti-thyroid antibody showed most accurate diagnostic performance. In detecting Hashimoto's thyroiditis, serum anti-thyroid antibody showed higher diagnostic accuracy than others. US also showed relatively high diagnostic accuracy.

  14. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  15. Evaluation of sacroiliitis: contrast-enhanced MRI with subtraction technique

    Energy Technology Data Exchange (ETDEWEB)

    Algin, Oktay; Gokalp, Gokhan; Baran, Bulent; Ocakoglu, Gokhan; Yazici, Zeynep [Uludag University, Medical Faculty, Department of Radiology, Gorukle, Bursa (Turkey)

    2009-10-15

    The purpose of the study was to investigate the diagnostic value of contrast-enhanced MRI using the subtraction technique in the detection of active sacroiliitis. Magnetic resonance imaging was performed in 8 asymptomatic volunteers and 50 patients with clinically suspected active sacroiliitis. On precontrast MR images, T1-weighted spin-echo images with and without fat saturation (T1WFS and T1W), STIR and 3D-FLASH images with fat saturation were obtained in the semicoronal plane using a 1.5 Tesla imager. Postcontrast MRI was performed using the same T1WFS sequence as before contrast injection for all volunteers and patients. Postcontrast images were subtracted from fat-suppressed precontrast images. Enhancement within the joint space and bone marrow was considered to demonstrate active sacroiliitis. In 50 patients (100 sacroiliac joints [SIJs]), 40 (76 SIJs) were considered to have active sacroiliitis based on MR images. Bone marrow edema was present in 33 patients (62 SIJs) on STIR images. Routine MRI allowed identification of contrast enhancement in SIJs on postcontrast T1WFS images in 31 patients (49 SIJs). Contrast enhancement was observed in 40 patients (76 SIJs) who were examined by MRI using the subtraction technique. Contrast enhancement was significantly more conspicuous on subtraction images than on non-subtracted postcontrast T1WFS images (Mann-Whitney U test, p<0.001). Contrast-enhanced MRI with subtraction technique may be useful for early detection of active sacroiliitis. (orig.)

  16. Tracer kinetic model-driven registration for dynamic contrast-enhanced MRI time-series data.

    Science.gov (United States)

    Buonaccorsi, Giovanni A; O'Connor, James P B; Caunce, Angela; Roberts, Caleb; Cheung, Sue; Watson, Yvonne; Davies, Karen; Hope, Lynn; Jackson, Alan; Jayson, Gordon C; Parker, Geoffrey J M

    2007-11-01

    Dynamic contrast-enhanced MRI (DCE-MRI) time series data are subject to unavoidable physiological motion during acquisition (e.g., due to breathing) and this motion causes significant errors when fitting tracer kinetic models to the data, particularly with voxel-by-voxel fitting approaches. Motion correction is problematic, as contrast enhancement introduces new features into postcontrast images and conventional registration similarity measures cannot fully account for the increased image information content. A methodology is presented for tracer kinetic model-driven registration that addresses these problems by explicitly including a model of contrast enhancement in the registration process. The iterative registration procedure is focused on a tumor volume of interest (VOI), employing a three-dimensional (3D) translational transformation that follows only tumor motion. The implementation accurately removes motion corruption in a DCE-MRI software phantom and it is able to reduce model fitting errors and improve localization in 3D parameter maps in patient data sets that were selected for significant motion problems. Sufficient improvement was observed in the modeling results to salvage clinical trial DCE-MRI data sets that would otherwise have to be rejected due to motion corruption. Copyright 2007 Wiley-Liss, Inc.

  17. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    Energy Technology Data Exchange (ETDEWEB)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J. [Department of Radiology, ' ' Aretaieion' ' Hospital,University of Athens Medical School, Athens (Greece); Voumvourakis, C.; Sfagos, C. [Department of Neurology, ' ' Eginiteion' ' Hospital, University of Athens Medical School, Athens (Greece)

    2004-03-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  18. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    International Nuclear Information System (INIS)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J.; Voumvourakis, C.; Sfagos, C.

    2004-01-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  19. Potential Cost Savings of Contrast-Enhanced Digital Mammography.

    Science.gov (United States)

    Patel, Bhavika K; Gray, Richard J; Pockaj, Barbara A

    2017-06-01

    The purpose of this article is to discuss whether the sensitivity and specificity of contrast-enhanced digital mammography (CEDM) render it a viable diagnostic alternative to breast MRI. That CEDM couples low-energy images (comparable to the diagnostic quality of standard mammography) and subtracted contrast-enhanced mammograms make it a cost-effective modality and a realistic substitute for the more costly breast MRI.

  20. Delayed contrast enhancement imaging of a murine model for ischemia reperfusion with carbon nanotube micro-CT.

    Directory of Open Access Journals (Sweden)

    Laurel M Burk

    Full Text Available We aim to demonstrate the application of free-breathing prospectively gated carbon nanotube (CNT micro-CT by evaluating a myocardial infarction model with a delayed contrast enhancement technique. Evaluation of murine cardiac models using micro-CT imaging has historically been limited by extreme imaging requirements. Newly-developed CNT-based x-ray sources offer precise temporal resolution, allowing elimination of physiological motion through prospective gating. Using free-breathing, cardiac-gated CNT micro-CT, a myocardial infarction model can be studied non-invasively and with high resolution. Myocardial infarction was induced in eight male C57BL/6 mice aged 8-12 weeks. The ischemia reperfusion model was achieved by surgically occluding the LAD artery for 30 minutes followed by 24 hours of reperfusion. Tail vein catheters were placed for contrast administration. Iohexol 300 mgI/mL was administered followed by images obtained in diastole. Iodinated lipid blood pool contrast agent was then administered, followed with images at systole and diastole. Respiratory and cardiac signals were monitored externally and used to gate the scans of free-breathing subjects. Seven control animals were scanned using the same imaging protocol. After imaging, the heart was harvested, cut into 1mm slices and stained with TTC. Post-processing analysis was performed using ITK-Snap and MATLAB. All animals demonstrated obvious delayed contrast enhancement in the left ventricular wall following the Iohexol injection. The blood pool contrast agent revealed significant changes in cardiac function quantified by 3-D volume ejection fractions. All subjects demonstrated areas of myocardial infarct in the LAD distribution on both TTC staining and micro-CT imaging. The CNT micro-CT system aids straightforward, free-breathing, prospectively-gated 3-D murine cardiac imaging. Delayed contrast enhancement allows identification of infarcted myocardium after a myocardial ischemic

  1. Urinary Iodine Clearance following Iodinated Contrast Administration: A Comparison of Euthyroid and Postthyroidectomy Subjects

    Directory of Open Access Journals (Sweden)

    Janice D. Ho

    2014-01-01

    Full Text Available Purpose. To compare iodine clearance following iodinated contrast administration in thyroidectomised thyroid cancer patients and euthyroid individuals. Methods. A convenience population (6 thyroidectomised thyroid cancer patients and 7 euthyroid controls was drawn from patients referred for iodinated contrast-enhanced computed tomography (CT studies. Subjects had sequential urine samples collected up to 6 months (50 samples from the thyroidectomised and 63 samples from the euthyroid groups. t-tests and generalised estimating equations (GEE were used to test for group differences in urinary iodine creatinine ratios. Results. Groups had similar urinary iodine creatinine ratios at baseline, with a large increase 2 weeks following iodinated contrast (P=0.005. Both groups had a return of urinary iodine creatinine ratios to baseline by 4 weeks, with no significant group differences overall or at any time point. Conclusions. Thyroidectomised patients did not have a significantly different urinary iodine clearance than euthyroid individuals following administration of iodinated contrast. Both had a return of urinary iodine creatinine ratios to baseline within 4 weeks.

  2. Dual-energy contrast-enhanced digital mammography: initial clinical results

    International Nuclear Information System (INIS)

    Dromain, Clarisse; Thibault, Fabienne; Tardivon, Anne; Muller, Serge; Rimareix, Francoise; Delaloge, Suzette; Balleyguier, Corinne

    2011-01-01

    To assess the diagnostic accuracy of Dual-Energy Contrast-Enhanced Digital Mammography (CEDM) as an adjunct to mammography (MX) versus MX alone and versus mammography plus ultrasound (US). 120 women with 142 suspect findings on MX and/or US underwent CEDM. A pair of low- and high-energy images was acquired using a modified full-field digital mammography system. Exposures were taken in MLO at 2 min and in CC at 4 min after the injection of 1.5 ml/kg of an iodinated contrast agent. One reader evaluated MX, US and CEDM images during 2 sessions 1 month apart. Sensitivity, specificity, and area under the ROC curve were estimated. The results from pathology and follow-up identified 62 benign and 80 malignant lesions. Areas under the ROC curves were significantly superior for MX+CEDM than it was for MX alone and for MX+US using BI-RADS. Sensitivity was higher for MX+CEDM than it was for MX (93% vs. 78%; p < 0.001) with no loss in specificity. The lesion size was closer to the histological size for CEDM. All 23 multifocal lesions were correctly detected by MX+CEDM vs. 16 and 15 lesions by MX and US respectively. Initial clinical results show that CEDM has better diagnostic accuracy than mammography alone and mammography+ultrasound. (orig.)

  3. A dimensionless dynamic contrast enhanced MRI parameter for intra-prostatic tumour target volume delineation: initial comparison with histology

    Science.gov (United States)

    Hrinivich, W. Thomas; Gibson, Eli; Gaed, Mena; Gomez, Jose A.; Moussa, Madeleine; McKenzie, Charles A.; Bauman, Glenn S.; Ward, Aaron D.; Fenster, Aaron; Wong, Eugene

    2014-03-01

    Purpose: T2 weighted and diffusion weighted magnetic resonance imaging (MRI) show promise in isolating prostate tumours. Dynamic contrast enhanced (DCE)-MRI has also been employed as a component in multi-parametric tumour detection schemes. Model-based parameters such as Ktrans are conventionally used to characterize DCE images and require arterial contrast agent (CR) concentration. A robust parameter map that does not depend on arterial input may be more useful for target volume delineation. We present a dimensionless parameter (Wio) that characterizes CR wash-in and washout rates without requiring arterial CR concentration. Wio is compared to Ktrans in terms of ability to discriminate cancer in the prostate, as demonstrated via comparison with histology. Methods: Three subjects underwent DCE-MRI using gadolinium contrast and 7 s imaging temporal resolution. A pathologist identified cancer on whole-mount histology specimens, and slides were deformably registered to MR images. The ability of Wio maps to discriminate cancer was determined through receiver operating characteristic curve (ROC) analysis. Results: There is a trend that Wio shows greater area under the ROC curve (AUC) than Ktrans with median AUC values of 0.74 and 0.69 respectively, but the difference was not statistically significant based on a Wilcoxon signed-rank test (p = 0.13). Conclusions: Preliminary results indicate that Wio shows potential as a tool for Ktrans QA, showing similar ability to discriminate cancer in the prostate as Ktrans without requiring arterial CR concentration.

  4. Perfusion magnetic resonance imaging and magnetic resonance spectroscopy of cerebral gliomas showing imperceptible contrast enhancement on conventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Batra, A.; Tripathi, R.P.; Singh, A.K.

    2004-01-01

    The purpose of the present paper was to evaluate the utility of perfusion MRI in cerebral gliomas showing imperceptible contrast enhancement on conventional MRI, and to evaluate the relationships of perfusion MRI and magnetic resonance (MR) spectroscopic results in these tumours. Twenty-two patients with histopathologically proven cerebral gliomas and showing insignificant contrast enhancement on conventional MR were included in the present study. All patients underwent perfusion MRI and MR spectroscopy on a 1.5-T MR system. Significant differences of the relative cerebral blood volume (rCBV) values and the choline : creatine ratios were noted between low-grade and anaplastic gliomas (P < 0.01). Good correlation was found between the rCBV values and the choline : creatine values (y = 0. 532x + 1.5643; r = 0.67). Perfusion MRI can be a useful tool in assessing the histopathological grade of non-contrast-enhancing cerebral gliomas. Along with MR spectroscopic imaging it can serve as an important technique for preoperative characterization of such gliomas, so that accurate targeting by stereotactic biopsies is possible. Copyright (2004) Blackwell Science Pty Ltd

  5. A contrast-enhanced ultrasound study of benign and malignant ...

    African Journals Online (AJOL)

    A contrast-enhanced ultrasound study of benign and malignant breast tissue. S Barnard, E Leen, T Cooke, W Angerson. Abstract. Objective. To determine the diagnostic value of haemodynamic contrast-enhanced ultrasound assessment in benign and malignant breast tissue, using histological examination as the reference ...

  6. Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA

    Energy Technology Data Exchange (ETDEWEB)

    Vogt, Florian M.; Hunold, Peter; Barkhausen, Joerg [University Hospital Schleswig-Holstein, Clinic for Radiology and Nuclear Medicine, Luebeck (Germany); Theysohn, Jens M.; Kinner, Sonja [University Hospital Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Michna, Dariusz [Elisabeth Hospital, Department of Neonatology, Essen (Germany); Neudorf, Ulrich [University Hospital Essen, Clinic for Pediatrics III, Essen (Germany); Quick, Harald H. [University of Erlangen-Nuernberg, Institute of Medical Physics, Erlangen (Germany)

    2013-09-15

    To evaluate time-resolved interleaved stochastic trajectories (TWIST) contrast-enhanced 4D magnetic resonance angiography (MRA) and compare it with 3D FLASH MRA in patients with congenital heart and vessel anomalies. Twenty-six patients with congenital heart and vessel anomalies underwent contrast-enhanced MRA with both 3D FLASH and 4D TWIST MRA. Images were subjectively evaluated regarding total image quality, artefacts, diagnostic value and added diagnostic value of 4D dynamic imaging. Quantitative comparison included signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness measurements. Three-dimensional FLASH MRA was judged to be significantly better in terms of image quality (4.0 {+-} 0.6 vs 3.4 {+-} 0.6, P < 0.05) and artefacts (3.8 {+-} 0.4 vs 3.3 {+-} 0.5, P < 0.05); no difference in diagnostic value was found (4.2 {+-} 0.4 vs 4.0 {+-} 0.4); important additional functional information was found in 21/26 patients. SNR and CNR were higher in the pulmonary trunk in 4D TWIST, but slightly higher in the systemic arteries in 3D FLASH. No difference in vessel sharpness delineation was found. Although image quality was inferior compared with 3D FLASH MRA, 4D TWIST MRA yields robust images and added diagnostic value through dynamic acquisition was found. Thus, 4D TWIST MRA is an attractive alternative to 3D FLASH MRA. (orig.)

  7. The role of contrast-enhanced endoscopic ultrasound in pancreatic adenocarcinoma

    DEFF Research Database (Denmark)

    Saftoiu, Adrian; Vilmann, Peter; Bhutani, Manoop S

    2016-01-01

    contrast agents for early detection, tridimensional and fusion techniques for enhanced staging and resectability assessment but also novel applications of perfusion imaging for monitoring ablative therapy, improved local detection through EUS-guided sampling of portal vein flow or enhanced drug delivery......Contrast-enhanced endoscopic ultrasound (CE-EUS) allows characterization, differentiation, and staging of focal pancreatic masses. The method has a high sensitivity and specificity for the diagnosis of pancreatic adenocarcinoma which is visualized as hypo-enhanced as compared to the rest...... of the parenchyma while chronic pancreatitis and neuroendocrine tumors are generally either iso-enhanced or hyper-enhanced. The development of contrast-enhanced low mechanical index harmonic imaging techniques used in real time during endoscopic ultrasound (EUS) allowed perfusion imaging and the quantification...

  8. Contrast-enhanced MRI of subchondral cysts in patients with or at risk for knee osteoarthritis: The MOST study

    International Nuclear Information System (INIS)

    Crema, M.D.; Roemer, F.W.; Marra, M.D.; Niu, J.; Lynch, J.A.; Felson, D.T.; Guermazi, A.

    2010-01-01

    Objective: The aim of the study was (1) to evaluate contrast enhancement patterns of subchondral cysts on magnetic resonance imaging and (2) to discuss possible radiological explanations of cyst enhancement based on existing theories of subchondral cyst formation in osteoarthritis. Materials and methods: The Multicenter Osteoarthritis Study (MOST) is a NIH-funded longitudinal observational study for individuals who have or are at high risk for knee osteoarthritis. All subjects with available non-enhanced and contrast-enhanced MRI were included. The tibiofemoral and patellofemoral joints were divided in 14 subregions. The presence and size of subchondral cysts and bone marrow edema-like lesions (BMLs) were scored semiquantitatively in each subregion on non-contrast-enhanced MRI from 0 to 3. Enhancement of subchondral cysts was evaluated on contrast-enhanced MRI as grade 0 (absent), grade 1 (partial enhancement), or grade 2 (full enhancement). The adjacent articular cartilage was scored in each subregion on non-enhanced MRI as grade 0 (intact), grade 1 (partial thickness loss), or grade 2 (full thickness loss). Results: Four hundred knees were included (1 knee per person, 5600 subregions). Subchondral cysts were detected in 260 subregions (4.6%). After intravenous contrast administration, 245 cysts (94.2%) showed full enhancement, 12 (4.6%) showed partial enhancement and 3 (1.2%) showed no enhancement. Enhancing BMLs were found in 237 (91.2%) subregions containing cysts, which were located adjacent or in the middle of BMLs. In 121 subregions (46.5%) having cysts, no adjacent full thickness cartilage loss was detected. Conclusion: Most subchondral cysts demonstrated full or partial contrast enhancement, and were located adjacent or in the midst of enhancing BMLs. As pure cystic lesions are not expected to enhance on MRI, the term 'subchondral cyst-like bone marrow lesion' might be appropriate to describe these lesions.

  9. Contrast-enhanced MRI of subchondral cysts in patients with or at risk for knee osteoarthritis: The MOST study

    Energy Technology Data Exchange (ETDEWEB)

    Crema, M.D., E-mail: michelcrema@gmail.co [Department of Radiology, Boston University School of Medicine, 820 Harrison Ave, FGH Building, 3rd Floor, Boston, MA 02118 (United States); Roemer, F.W., E-mail: frank.roemer@klinikum-augsburg.d [Department of Radiology, Boston University School of Medicine, 820 Harrison Ave, FGH Building, 3rd Floor, Boston, MA 02118 (United States); Department of Radiology, Klinikum Augsburg, Stenglinstrasse 2, Augsburg 86156 (Germany); Marra, M.D., E-mail: monicadiasmarra@gmail.co [Department of Radiology, Boston University School of Medicine, 820 Harrison Ave, FGH Building, 3rd Floor, Boston, MA 02118 (United States); Niu, J., E-mail: niujp@bu.ed [Clinical Epidemiology Research and Training Unit, Boston University School of Medicine, 650 Albany Street, X Building, Suite 200, Boston, MA 02118 (United States); Lynch, J.A., E-mail: jlynch@psg.ucsf.ed [Department of Epidemiology and Biostatistics, University of California at San Francisco, 185 Berry Street, Lobby 5, Suite 5700, San Francisco, CA 94107 (United States); Felson, D.T., E-mail: dfelson@bu.ed [Clinical Epidemiology Research and Training Unit, Boston University School of Medicine, 650 Albany Street, X Building, Suite 200, Boston, MA 02118 (United States); Guermazi, A., E-mail: ali.guermazi@bmc.or [Department of Radiology, Boston University School of Medicine, 820 Harrison Ave, FGH Building, 3rd Floor, Boston, MA 02118 (United States)

    2010-07-15

    Objective: The aim of the study was (1) to evaluate contrast enhancement patterns of subchondral cysts on magnetic resonance imaging and (2) to discuss possible radiological explanations of cyst enhancement based on existing theories of subchondral cyst formation in osteoarthritis. Materials and methods: The Multicenter Osteoarthritis Study (MOST) is a NIH-funded longitudinal observational study for individuals who have or are at high risk for knee osteoarthritis. All subjects with available non-enhanced and contrast-enhanced MRI were included. The tibiofemoral and patellofemoral joints were divided in 14 subregions. The presence and size of subchondral cysts and bone marrow edema-like lesions (BMLs) were scored semiquantitatively in each subregion on non-contrast-enhanced MRI from 0 to 3. Enhancement of subchondral cysts was evaluated on contrast-enhanced MRI as grade 0 (absent), grade 1 (partial enhancement), or grade 2 (full enhancement). The adjacent articular cartilage was scored in each subregion on non-enhanced MRI as grade 0 (intact), grade 1 (partial thickness loss), or grade 2 (full thickness loss). Results: Four hundred knees were included (1 knee per person, 5600 subregions). Subchondral cysts were detected in 260 subregions (4.6%). After intravenous contrast administration, 245 cysts (94.2%) showed full enhancement, 12 (4.6%) showed partial enhancement and 3 (1.2%) showed no enhancement. Enhancing BMLs were found in 237 (91.2%) subregions containing cysts, which were located adjacent or in the middle of BMLs. In 121 subregions (46.5%) having cysts, no adjacent full thickness cartilage loss was detected. Conclusion: Most subchondral cysts demonstrated full or partial contrast enhancement, and were located adjacent or in the midst of enhancing BMLs. As pure cystic lesions are not expected to enhance on MRI, the term 'subchondral cyst-like bone marrow lesion' might be appropriate to describe these lesions.

  10. Serial contrast-enhanced magnetic resonance and magnetization transfer in the study of patients with multiple sclerosis; Resonancia magnetica con contraste y transferencia de magnetizacion en el estudio seriado de pacientes con esclerosis multiple

    Energy Technology Data Exchange (ETDEWEB)

    Rovira, A; Alonso, J; Cucurella, G; Nos, C; Tintore, M; Pedraza, S; Rio, J; Montalban, X [Hospital General i Universitari Vall d` Hebron. Barcelona (Spain)

    1998-12-31

    To demonstrate the changes in the magnetization transfer ratio (MTR) of different demyelinating plaques, correlating them with the baseline values in T1-weighted contrast-enhanced magnetic resonance (MR) sequences in order to relate them more closely to the underlying disease. The study was based on 33 demyelinating plaques obtained from six patients clinically diagnosed as having remitting-recurring multiple sclerosis (MS). All the patients underwent two MR studies at a 3 to 5-month interval, including contrast-enhanced T1 and T2- weighted sequences and magnetization transfer images. The latter were used to calculate the MTR for each of the demyelinating plaques included in the study. The statistical analysis of the results obtained revealed statistically significant between initial MTR values and those of subsequent T1-weighted sequences. The MTR demonstrate significant differences between plaques according to contrast-enhanced T1-weigh tes sequences, probably indicating variable degrees of edema, demyelination and tissue destruction. These differences should be taken into account to enable the use of T1-weighted sequences to quantify the lesion load in MS patients. (Author) 35 refs.

  11. Contrast-enhanced MRI findings of the knee in healthy children; establishing normal values

    Energy Technology Data Exchange (ETDEWEB)

    Hemke, Robert; Maas, Mario [University of Amsterdam, Department of Radiology and Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands); Berg, J.M. van den; Schonenberg-Meinema, Dieneke; Kuijpers, Taco W. [University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Diseases, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Nusman, Charlotte M. [University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Diseases, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis (OLVG), Department of Pediatrics, Amsterdam (Netherlands); Gulik, E.C. van; Barendregt, Anouk M. [University of Amsterdam, Department of Radiology and Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Diseases, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Dolman, Koert M. [Onze Lieve Vrouwe Gasthuis (OLVG), Department of Pediatrics, Amsterdam (Netherlands); Reade, Department of Pediatric Rheumatology, Amsterdam (Netherlands)

    2018-03-15

    To define normative standards for the knee in healthy children using contrast-enhanced MRI, focusing on normal synovial membrane thickness. Secondly, presence of joint fluid and bone marrow oedema was evaluated. For this study, children without disorders potentially resulting in (accompanying) arthritis were included. Patients underwent clinical assessments, followed by contrast-enhanced MRI. MRI features were evaluated in consensus using the Juvenile Arthritis MRI Scoring (JAMRIS) system. Additionally, the presence of joint fluid was evaluated. No cartilage lesions or bone abnormalities were observed. We included 57 healthy children. The overall mean thickness of the normal synovial membrane was 0.4 mm (min-max; 0.0-1.8mm). The synovium was thickest around the cruciate ligaments and retropatellar and suprapatellar regions. The mean overall diameter of the largest pocket of joint fluid was 2.8 mm (min-max; 0.9-8.0mm). Bone marrow changes were observed in three children (all in the apex patellae). The normal synovial membrane was maximally 1.8 mm thick, indicating that the JAMRIS cut-off value of 2 mm can be considered a valid measure for evaluating synovial hypertrophy. Some joint fluid and bone marrow changes suggestive of bone marrow oedema in the apex patellae can be seen in healthy children. (orig.)

  12. Inflammatory aortic arch syndrome: contrast-enhanced, three-dimensional MR - angiography in stenotic lesions

    International Nuclear Information System (INIS)

    Both, M.; Mueller-Huelsbeck, S.; Biederer, J.; Heller, M.; Reuter, M.

    2004-01-01

    Purpose: To determine the value of contrast-enhanced, three-dimensional MR angiography for the evaluation of stenotic and occlusive vascular lesions in inflammatory aortic arch syndrome. Materials and Methods: 14 patients with inflammatory aortic arch syndrome (giant cell arteritis: n = 8, Takayasu arteritis: n = 4, ankylosing spondylitis: n = 1 sarcoidosis: n = 1) underwent MR angiography of the aortic arch and the supra-aortic vessels (n = 15,2 patients were examined twice) and of the abdominal aorta (n = 2). MRA was performed using a 3D-FLASH sequence (TR/TE 4.6/1.8 ms, flip angle 30 ) on a 1.5T system. MRA imaging was compared with the findings of DSA, which served as gold standard. Results: In a total of 467 examined vascular territories, DSA revealed 50 stenoses and 35 occlusions. All lesions were detected by MRA. In 23 segments, the degree of stenosis was overestimated by MRA. Sensitivity and specificity of MRA were 100% and 94,3%, positive and negative predictive values were 73.6 and 100%, and the accuracy was 95,1%. Conclusions: Despite a tendency to overestimate stenoses, contrast-enhanced three-dimensional MR angiography is a valid, non-invasive technique in the assessment of inflammatory aortic arch syndrome. (orig.) [de

  13. Contrast-enhanced MRI findings of the knee in healthy children; establishing normal values

    International Nuclear Information System (INIS)

    Hemke, Robert; Maas, Mario; Berg, J.M. van den; Schonenberg-Meinema, Dieneke; Kuijpers, Taco W.; Nusman, Charlotte M.; Gulik, E.C. van; Barendregt, Anouk M.; Dolman, Koert M.

    2018-01-01

    To define normative standards for the knee in healthy children using contrast-enhanced MRI, focusing on normal synovial membrane thickness. Secondly, presence of joint fluid and bone marrow oedema was evaluated. For this study, children without disorders potentially resulting in (accompanying) arthritis were included. Patients underwent clinical assessments, followed by contrast-enhanced MRI. MRI features were evaluated in consensus using the Juvenile Arthritis MRI Scoring (JAMRIS) system. Additionally, the presence of joint fluid was evaluated. No cartilage lesions or bone abnormalities were observed. We included 57 healthy children. The overall mean thickness of the normal synovial membrane was 0.4 mm (min-max; 0.0-1.8mm). The synovium was thickest around the cruciate ligaments and retropatellar and suprapatellar regions. The mean overall diameter of the largest pocket of joint fluid was 2.8 mm (min-max; 0.9-8.0mm). Bone marrow changes were observed in three children (all in the apex patellae). The normal synovial membrane was maximally 1.8 mm thick, indicating that the JAMRIS cut-off value of 2 mm can be considered a valid measure for evaluating synovial hypertrophy. Some joint fluid and bone marrow changes suggestive of bone marrow oedema in the apex patellae can be seen in healthy children. (orig.)

  14. Is contrast-enhanced CT indicated in acute head injury

    International Nuclear Information System (INIS)

    Mauser, H.W.; Nieuwenhuizen, O. van; Veiga-Pires, J.A.

    1984-01-01

    The authors discuss the value of intravenous contrast enhancement in CT scanning in acute head injury. In a series of seventy consecutive patients they conclude that no incremental information was obtained by performing contrast-enhanced CT scans in the acute phase of the head injury. (orig.)

  15. Vesicoureteral reflux in children: comparison of contrast - enhanced voiding ultrasonography with radiographic voiding cystourethrography - preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Chong Hyun; Kim, Hyun Joo; Goo, Hyun Woo; Kim, Hungy; Lee, Jung Joo; Kim, Ellen Ai-Rhan; Kim, Ki Soo; Park, Young Seo; Pi, Soo Young [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    2001-01-01

    To compared the usefullness of contrst-enhanced voiding ultrasonogrphy (US) with that of radiogrphic voiding cystourethrography (VCUG) for the diagnosis of vesicoureteral reflux (VUR) in children. Ninety-five kidney-ureter units of 47 patients referred for investigation of VUR underwent contrast -enhanced voiding US followed by radiographic VCUG. After baseline US examination of the urinaru tract, residual urine in the bladder was drained through an inserted Foley catheter and the bladder was gravityfilled at a height of 1 m with normal saline. A galactose-based, microbubble-containning echo-enhancing agent (Lvovist; Dchering, Berlin, Germany) was then administered. The amount of this was approximately 10% of bldder capacity, and VUR was diagnosed when microbubbles appeared in the ureter or pelvocalyceal system. Using radiographic VCUG as a reference point, the accuracy with which contrst-enhanced voiding US detected VUR was calcilated. In 87 of 95 kidney-ureter units (91.6%), the two methods showed similiar results regarding the diagnosis or exclusion of VUR, which was detected by both in 12 units, but by neither in 75. VUR was shown to occcur in a total of 20 units, but in eight of these by one method only. In two units, VUR detected by contrast-enhanced voiding US was was not demostarted by radiographic VCUG; in six units, the resverse was true. In the detection of VUR, contrast-enhanced voiding us showed a sensitivity of 66.7%, a sprcificity of 97.4%, a positive predictive value of 85.7%, and a negative predictive value of 92.6%. Contrst-enhanced voiding US is highly specific and has high positive and nagative predictive values; its sensitivity, however, is not sufficiently high. The modality appears to be a useful diagnostic tool for the detection of VUR without exposure to ionizing radiation, though to be certain of its value, more experience of its use its first required.

  16. Vesicoureteral reflux in children: comparison of contrast - enhanced voiding ultrasonography with radiographic voiding cystourethrography - preliminary report

    International Nuclear Information System (INIS)

    Yoon, Chong Hyun; Kim, Hyun Joo; Goo, Hyun Woo; Kim, Hungy; Lee, Jung Joo; Kim, Ellen Ai-Rhan; Kim, Ki Soo; Park, Young Seo; Pi, Soo Young

    2001-01-01

    To compared the usefullness of contrst-enhanced voiding ultrasonogrphy (US) with that of radiogrphic voiding cystourethrography (VCUG) for the diagnosis of vesicoureteral reflux (VUR) in children. Ninety-five kidney-ureter units of 47 patients referred for investigation of VUR underwent contrast -enhanced voiding US followed by radiographic VCUG. After baseline US examination of the urinaru tract, residual urine in the bladder was drained through an inserted Foley catheter and the bladder was gravityfilled at a height of 1 m with normal saline. A galactose-based, microbubble-containning echo-enhancing agent (Lvovist; Dchering, Berlin, Germany) was then administered. The amount of this was approximately 10% of bldder capacity, and VUR was diagnosed when microbubbles appeared in the ureter or pelvocalyceal system. Using radiographic VCUG as a reference point, the accuracy with which contrst-enhanced voiding US detected VUR was calcilated. In 87 of 95 kidney-ureter units (91.6%), the two methods showed similiar results regarding the diagnosis or exclusion of VUR, which was detected by both in 12 units, but by neither in 75. VUR was shown to occcur in a total of 20 units, but in eight of these by one method only. In two units, VUR detected by contrast-enhanced voiding US was was not demostarted by radiographic VCUG; in six units, the resverse was true. In the detection of VUR, contrast-enhanced voiding us showed a sensitivity of 66.7%, a sprcificity of 97.4%, a positive predictive value of 85.7%, and a negative predictive value of 92.6%. Contrst-enhanced voiding US is highly specific and has high positive and nagative predictive values; its sensitivity, however, is not sufficiently high. The modality appears to be a useful diagnostic tool for the detection of VUR without exposure to ionizing radiation, though to be certain of its value, more experience of its use its first required

  17. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    International Nuclear Information System (INIS)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah

    2014-01-01

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after 18 F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced PET

  18. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced

  19. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    Directory of Open Access Journals (Sweden)

    Nicolas D. Prionas, MD, PhD

    2015-01-01

    Full Text Available Dedicated breast computed tomography (bCT generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obtained after diagnosis. Lesion enhancement at contrast-enhanced breast CT matched previously published enhancement values of breast cancer. Contrast-enhanced dedicated bCT provided high-resolution tomographic images and physiologic contrast enhancement data that facilitated the detection of an early breast cancer.

  20. Contrast Enhancement Algorithm Based on Gap Adjustment for Histogram Equalization

    Science.gov (United States)

    Chiu, Chung-Cheng; Ting, Chih-Chung

    2016-01-01

    Image enhancement methods have been widely used to improve the visual effects of images. Owing to its simplicity and effectiveness histogram equalization (HE) is one of the methods used for enhancing image contrast. However, HE may result in over-enhancement and feature loss problems that lead to unnatural look and loss of details in the processed images. Researchers have proposed various HE-based methods to solve the over-enhancement problem; however, they have largely ignored the feature loss problem. Therefore, a contrast enhancement algorithm based on gap adjustment for histogram equalization (CegaHE) is proposed. It refers to a visual contrast enhancement algorithm based on histogram equalization (VCEA), which generates visually pleasing enhanced images, and improves the enhancement effects of VCEA. CegaHE adjusts the gaps between two gray values based on the adjustment equation, which takes the properties of human visual perception into consideration, to solve the over-enhancement problem. Besides, it also alleviates the feature loss problem and further enhances the textures in the dark regions of the images to improve the quality of the processed images for human visual perception. Experimental results demonstrate that CegaHE is a reliable method for contrast enhancement and that it significantly outperforms VCEA and other methods. PMID:27338412

  1. Contrast Enhancement Algorithm Based on Gap Adjustment for Histogram Equalization

    Directory of Open Access Journals (Sweden)

    Chung-Cheng Chiu

    2016-06-01

    Full Text Available Image enhancement methods have been widely used to improve the visual effects of images. Owing to its simplicity and effectiveness histogram equalization (HE is one of the methods used for enhancing image contrast. However, HE may result in over-enhancement and feature loss problems that lead to unnatural look and loss of details in the processed images. Researchers have proposed various HE-based methods to solve the over-enhancement problem; however, they have largely ignored the feature loss problem. Therefore, a contrast enhancement algorithm based on gap adjustment for histogram equalization (CegaHE is proposed. It refers to a visual contrast enhancement algorithm based on histogram equalization (VCEA, which generates visually pleasing enhanced images, and improves the enhancement effects of VCEA. CegaHE adjusts the gaps between two gray values based on the adjustment equation, which takes the properties of human visual perception into consideration, to solve the over-enhancement problem. Besides, it also alleviates the feature loss problem and further enhances the textures in the dark regions of the images to improve the quality of the processed images for human visual perception. Experimental results demonstrate that CegaHE is a reliable method for contrast enhancement and that it significantly outperforms VCEA and other methods.

  2. Supra-aortic low-dose contrast-enhanced time-resolved magnetic resonance (MR) angiography at 3 T: comparison with time-of-flight MR angiography and high-resolution contrast-enhanced MR angiography.

    Science.gov (United States)

    Lee, Youn-Joo; Kim, Bum-soo; Koo, Ja-Sung; Kim, Bom-Yi; Jang, Jinhee; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin

    2015-06-01

    Low-dose, time-resolved, contrast-enhanced, magnetic resonance angiography (TR-CEMRA) has been described previously; however, a comparative study between low dose TR-CEMRA and time-of-flight MRA (TOF-MRA) in the diagnosis of supra-aortic arterial stenosis has not yet been published. To demonstrate the feasibility and effectiveness of low-dose TR-CEMRA compared with TOF-MRA, using high-resolution contrast-enhanced MRA (HR-CEMRA) as the reference standard. This prospective study consisted of 30 consecutive patients. All patients underwent TOF-MRA of the neck and circle of Willis and supra-aortic HR-CEMRA, followed by supra-aortic low-dose TR-CEMRA. Gadoterate meglumine (Gd-DOTA, Dotarem(®), Guerbet, Roissy CdG Cedex, France) was injected at a dose of 0.1 mmol/kg for HR-CEMRA, followed by a 0.03 mmol/kg bolus for low-dose TR-CEMRA. Three readers evaluated the assessibility and image quality, and then two readers classified each stenosis into the following categories: normal (0-30%), mild stenosis (31-50%), moderate (51-70%), severe (71-99%), and occlusion. TR-CEMRA and HR-CEMRA showed a greater number of assessable arterial segments than TOF-MRA (P supra-aortic arterial stenosis, and could be more useful option than TOF-MRA. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  3. Centrifugal (inside-out) enhancement of liver hemangiomas: A possible atypical appearance on contrast-enhanced US

    International Nuclear Information System (INIS)

    Bartolotta, Tommaso Vincenzo; Taibbi, Adele; Galia, Massimo; Lo Re, Giuseppe; La Grutta, Ludovico; Grassi, Roberto; Midiri, Massimo

    2007-01-01

    Objective: To report the prevalence and to describe the atypical centrifugal (inside-out) appearance of contrast-enhancement of liver hemangiomas on contrast-enhanced sonography. Materials and methods: Baseline and SonoVue-enhanced ultrasonography of 92 patients with 158 liver hemangiomas - considered atypical at grey-scale examination and confirmed by computed tomography, magnetic resonance imaging and ultrasound follow-up - were reviewed in consensus by two experienced radiologists, who evaluated baseline echogenicity and the dynamic enhancement pattern of each lesion looking for the presence of central enhancing foci in the arterial phase followed by a centrifugal (inside-out) enhancement in the portal-venous and late phases. Results: After administration of SonoVue, 12/158 hemangiomas (7.6%) (size range: 1-7 cm; mean: 3.2 cm) in seven patients (5 women, 2 men; age range: 34-71 years, mean: 50.8 years) showed a central enhancing focus in the arterial phase followed by a centrifugal enhancement in the portal-venous and late phases. In all cases centrifugal enhancement was incomplete at contrast-enhanced sonography, whereas computed tomography and/or magnetic resonance imaging were able to depict a complete and homogeneous fill-in. Conclusion: Radiologist should be aware that centrifugal (inside-out) appearance on contrast-enhanced sonography is a rare but possible feature of liver hemangioma

  4. Centrifugal (inside-out) enhancement of liver hemangiomas: A possible atypical appearance on contrast-enhanced US

    Energy Technology Data Exchange (ETDEWEB)

    Bartolotta, Tommaso Vincenzo [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: tv.bartolotta@unipa.it; Taibbi, Adele [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: taibbi_adele@yahoo.it; Galia, Massimo [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: mgalia@yahoo.com; Lo Re, Giuseppe [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: giuseppe.lore12@tin.it; La Grutta, Ludovico [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: lagrutta@mbox.infcom.it; Grassi, Roberto [Institute of Radiology, Second University of Naples, Piazza Miraglia, 80138 Naples (Italy)], E-mail: roberto.grassi@libero.it; Midiri, Massimo [Department of Radiology, University of Palermo, Via Del Vespro 127, 90127 Palermo (Italy)], E-mail: mmidiri@hotmail.com

    2007-12-15

    Objective: To report the prevalence and to describe the atypical centrifugal (inside-out) appearance of contrast-enhancement of liver hemangiomas on contrast-enhanced sonography. Materials and methods: Baseline and SonoVue-enhanced ultrasonography of 92 patients with 158 liver hemangiomas - considered atypical at grey-scale examination and confirmed by computed tomography, magnetic resonance imaging and ultrasound follow-up - were reviewed in consensus by two experienced radiologists, who evaluated baseline echogenicity and the dynamic enhancement pattern of each lesion looking for the presence of central enhancing foci in the arterial phase followed by a centrifugal (inside-out) enhancement in the portal-venous and late phases. Results: After administration of SonoVue, 12/158 hemangiomas (7.6%) (size range: 1-7 cm; mean: 3.2 cm) in seven patients (5 women, 2 men; age range: 34-71 years, mean: 50.8 years) showed a central enhancing focus in the arterial phase followed by a centrifugal enhancement in the portal-venous and late phases. In all cases centrifugal enhancement was incomplete at contrast-enhanced sonography, whereas computed tomography and/or magnetic resonance imaging were able to depict a complete and homogeneous fill-in. Conclusion: Radiologist should be aware that centrifugal (inside-out) appearance on contrast-enhanced sonography is a rare but possible feature of liver hemangioma.

  5. Safety and adverse effects during 24 hours after contrast-enhanced MRI with gadobenate dimeglumine (MultiHance {sup registered}) in children

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Guenther; Schuerholz, Hellmut; Buecker, Arno; Fries, Peter [Homburg University Hospital, Homburg, Saar (Germany); Kirchin, Miles A. [Bracco Imaging SpA, Milan (Italy)

    2013-02-15

    Gadolinium-based MR contrast agents have long been considered safe for routine diagnostic imaging. However, the advent of nephrogenic systemic fibrosis (NSF) among certain patients with severe renal insufficiency has brought the issue of safety into question. Nowhere is safety of greater concern than among children who frequently require multiple contrast-enhanced MRI examinations over an extended period of time. To retrospectively evaluate the safety of gadobenate dimeglumine for contrast-enhanced (CE) MRI across a range of indications. Two hundred pediatric inpatients (age: 4 days to 15 years) underwent CE MRI as part of clinical routine. The children received a gadobenate dimeglumine dose of either 0.05 mmol/kg body weight (liver, abdominal imaging, musculoskeletal imaging, brain and other rare indications) or 0.1 mmol/kg bodyweight (cardiovascular imaging, MR-urography). Young (< 8 years) children with congenital heart disease were intubated and underwent MRA evaluation with controlled ventilation. Monitoring for adverse events was performed for at least 24 h after each gadobenate dimeglumine injection. Depending on clinical necessity, laboratory measurements and, in some cases, vital sign and ECG determinations were made before and after contrast injection. Safety was evaluated by age group, indication and dose administered. No clinically adverse events were reported among children who had one MRI scan only or among children who had several examinations. There were no changes in creatinine or bilirubin levels even in very young children. No adverse events were recorded during the first 24 h following administration of gadobenate dimeglumine in 200 children. (orig.)

  6. Contrast agent enhanced pQCT of articular cartilage

    Energy Technology Data Exchange (ETDEWEB)

    Kallioniemi, A S [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Jurvelin, J S [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Nieminen, M T [Department of Diagnostic Radiology, POB 50, 90029 OYS, Oulu University Hospital, Oulu (Finland); Lammi, M J [Department of Anatomy, Institute of Biomedicine, University of Kuopio, POB 1627, 70211 Kuopio (Finland); Toeyraes, J [Department of Physics, University of Kuopio, POB 1627, 70211 Kuopio (Finland)

    2007-02-21

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T{sub 1,Gd} and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally

  7. Contrast agent enhanced pQCT of articular cartilage

    Science.gov (United States)

    Kallioniemi, A. S.; Jurvelin, J. S.; Nieminen, M. T.; Lammi, M. J.; Töyräs, J.

    2007-02-01

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T1,Gd and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n = 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r = -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally

  8. Contrast agent enhanced pQCT of articular cartilage

    International Nuclear Information System (INIS)

    Kallioniemi, A S; Jurvelin, J S; Nieminen, M T; Lammi, M J; Toeyraes, J

    2007-01-01

    The delayed gadolinium enhanced MRI of cartilage (dGEMRIC) technique is the only non-invasive means to estimate proteoglycan (PG) content in articular cartilage. In dGEMRIC, the anionic paramagnetic contrast agent gadopentetate distributes in inverse relation to negatively charged PGs, leading to a linear relation between T 1,Gd and spatial PG content in tissue. In the present study, for the first time, contrast agent enhanced peripheral quantitative computed tomography (pQCT) was applied, analogously to dGEMRIC, for the quantitative detection of spatial PG content in cartilage. The suitability of two anionic radiographic contrast agents, gadopentetate and ioxaglate, to detect enzymatically induced PG depletion in articular cartilage was investigated. First, the interrelationships of x-ray absorption, as measured with pQCT, and the contrast agent solution concentration were investigated. Optimal contrast agent concentrations for the following experiments were selected. Second, diffusion rates for both contrast agents were investigated in intact (n = 3) and trypsin-degraded (n 3) bovine patellar cartilage. The contrast agent concentration of the cartilaginous layer was measured prior to and 2-27 h after immersion. Optimal immersion time for the further experiments was selected. Third, the suitability of gadopentetate and ioxaglate enhanced pQCT to detect the enzymatically induced specific PG depletion was investigated by determining the contrast agent concentrations and uronic acid and water contents in digested and intact osteochondral samples (n = 16). After trypsin-induced PG loss (-70%, p < 0.05) the penetration of gadopentetate and ioxaglate increased (p < 0.05) by 34% and 48%, respectively. Gadopentetate and ioxaglate concentrations both showed strong correlation (r = -0.95, r -0.94, p < 0.01, respectively) with the uronic acid content. To conclude, contrast agent enhanced pQCT provides a technique to quantify PG content in normal and experimentally degraded

  9. Contrast enhancement of cranial lesions in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lewander, R; Bergstroem, M; Bergvall, U [Kungliga Karolinska Mediko-Kirurgiska Inst., Stockholm (Sweden)

    1978-01-01

    The time course of enhancement in apparently normal brain tissue, edema and focal lesions during 30 to 60 min after intravenous injection of vascular contrast medium was evaluated in a series of 41 pateints with differnt intracranial lesions. The attenuation of apparently normal unenhanced brain tissue varied with the level of the scan, mainly an effect of beam hardening. Different types of enhancement response are discussed in terms of a 3-compartment model. The differential diagnostic potential of contrast enhancement in the early phase needs further evaluation using instruments with short scanning time, while the late phase of enhancement must be recorded with the use of a reliable head fixation to provide reproducibility of repeat measurements.

  10. Dual-energy CT in the assessment of mediastinal lymph nodes: Comparative study of virtual non-contrast and true non-contrast images

    International Nuclear Information System (INIS)

    Yoo, Seon Young; Kim, Yoo Kyung; Cho, Hyun Hae; Choi, Mi Joo; Shim, Sung Shine; Lee, Jeong Kyong; Baek, Seung Yon

    2013-01-01

    To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation ≤ the aorta; 1, > the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0.612). The mean absolute difference was 7.8 ± 7.6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65.2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (κ value, 0.335). Five of 16 nodes (31.3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0.455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0.245). VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.

  11. Dual-energy CT in the assessment of mediastinal lymph nodes: Comparative study of virtual non-contrast and true non-contrast images

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seon Young; Kim, Yoo Kyung; Cho, Hyun Hae; Choi, Mi Joo; Shim, Sung Shine; Lee, Jeong Kyong; Baek, Seung Yon [School of Medicine, Ewha Womans University, Seou (Korea, Republic of)

    2013-06-15

    To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation ≤ the aorta; 1, > the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0.612). The mean absolute difference was 7.8 ± 7.6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65.2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (κ value, 0.335). Five of 16 nodes (31.3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0.455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0.245). VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.

  12. Dual-energy CT in the assessment of mediastinal lymph nodes: comparative study of virtual non-contrast and true non-contrast images.

    Science.gov (United States)

    Yoo, Seon Young; Kim, Yookyung; Cho, Hyun Hae; Choi, Mi Joo; Shim, Sung Shine; Lee, Jeong Kyong; Baek, Seung Yon

    2013-01-01

    To evaluate the reliability of virtual non-contrast (VNC) images reconstructed from contrast-enhanced, dual-energy scans compared with true non-contrast (TNC) images in the assessment of high CT attenuation or calcification of mediastinal lymph nodes. A total of 112 mediastinal nodes from 45 patients who underwent non-contrast and dual-energy contrast-enhanced scans were analyzed. Node attenuation in TNC and VNC images was compared both objectively, using computed tomography (CT) attenuation, and subjectively, via visual scoring (0, attenuation ≤ the aorta; 1, > the aorta; 2, calcification). The relationship among attenuation difference between TNC and VNC images, CT attenuation in TNC images, and net contrast enhancement (NCE) was analyzed. CT attenuation in TNC and VNC images showed moderate agreement (intraclass correlation coefficient, 0.612). The mean absolute difference was 7.8 ± 7.6 Hounsfield unit (HU) (range, 0-36 HU), and the absolute difference was equal to or less than 10 HU in 65.2% of cases (73/112). Visual scores in TNC and VNC images showed fair agreement (κ value, 0.335). Five of 16 nodes (31.3%) which showed score 1 (n = 15) or 2 (n = 1) in TNC images demonstrated score 1 in VNC images. The TNC-VNC attenuation difference showed a moderate positive correlation with CT attenuation in TNC images (partial correlation coefficient [PCC] adjusted by NCE: 0.455) and a weak negative correlation with NCE (PCC adjusted by CT attenuation in TNC: -0.245). VNC images may be useful in the evaluation of mediastinal lymph nodes by providing additional information of high CT attenuation of nodes, although it is underestimated compared with TNC images.

  13. Diffusion-weighted imaging versus contrast-enhanced MR imaging for the differentiation of renal oncocytomas and chromophobe renal cell carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yan; Wang, Haiyi; Shen, Yanguang; Ma, Lu; Pan, Jingjing; Ye, Huiyi [Chinese PLA General Hospital, Department of Radiology, Beijing (China); Guo, Aitao [Chinese PLA General Hospital, Department of Pathology, Beijing (China); Wang, Jia [Handan Central Hosptical, Department of Radiology, Hebei (China); Kang, Suhai [264 Hospital of PLA, X-ray Department, Taiyuan (China)

    2017-12-15

    To compare the performance of diffusion-weighted imaging (DWI) with that of contrast-enhanced MRI in differentiating renal oncocytomas from chromophobe renal cell carcinomas (RCCs). We recruited 48 patients with histopathologically confirmed renal oncocytomas (n=16) and chromophobe RCCs (n=32). All patients underwent preoperative DWI and contrast-enhanced MRI. Apparent diffusion coefficient (ADC) and signal intensity were measured in each patient. ADC ratio and percentage of signal intensity change were calculated. Mean ADC values for renal oncocytomas were significantly higher than those for chromophobe RCCs (1.59±0.21 vs. 1.09±0.29 x 10{sup -3} mm{sup 2}/s, p < 0.001). Area under the ROC curve, sensitivity and specificity were 0.931, 87.5% and 84.4%, respectively, for ADC measurement of DW imaging; 0.825, 87.5% and 75%, respectively, for enhancement ratio (p > 0.05). Adding ADC values to the enhancement ratios in the ROC, analysis to differentiate renal oncocytoma from chromophobe RCCs increased specificity from 75 to 87.5% at 87.5% sensitivity without significantly increasing the AUC (0.930). Both DWI and contrast-enhanced MRI may assist in differentiating renal oncocytomas from chromophobe RCCs, with DWI showing higher diagnostic value. The combination of the two parameters could potentially provide better performance in distinguishing these two tumours. (orig.)

  14. Contrast-enhanced MR imaging monitoring of acute tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Ranney, D.F.; Cohen, J.M.; Antich, P.P.; Endman, W.A.; Kulkarni, P.; Weinreb, J.C.; Giovanella, B.

    1987-01-01

    Treatment responses of human malignant melanomas were monitored at millimeter resolution in athymic mice by injecting a new polymeric contrast agent, Gd-DTPA-dextran (0.1 mmol Gd/kg, intravenously). Proton MR imaging (0.35 T, spin-echo, repetition time = 0.5 second, echo time = 50 msec) was performed 30 hours after administering diphtheria toxin. Pre-contrast medium images revealed only homogeneous intermediate-intensity tumor masses. Post-contrast medium images of untreated (viable) tumors demonstrated 32% enhancement throughout the entire mass. Post-contrast medium images of toxin-treated tumors revealed marked enhancement (65%) of the histologically viable outer rims, lesser enhancement (38%) of heavily damaged subregions, and no enhancement of dead tumor. These acute, contrast medium-enhanced MR images accurately identified tumor subregions that survived for longer than one week

  15. Algorithms for contrast enhancement of electronic portal images

    International Nuclear Information System (INIS)

    Díez, S.; Sánchez, S.

    2015-01-01

    An implementation of two new automatized image processing algorithms for contrast enhancement of portal images is presented as suitable tools which facilitate the setup verification and visualization of patients during radiotherapy treatments. In the first algorithm, called Automatic Segmentation and Histogram Stretching (ASHS), the portal image is automatically segmented in two sub-images delimited by the conformed treatment beam: one image consisting of the imaged patient obtained directly from the radiation treatment field, and the second one is composed of the imaged patient outside it. By segmenting the original image, a histogram stretching can be independently performed and improved in both regions. The second algorithm involves a two-step process. In the first step, a Normalization to Local Mean (NLM), an inverse restoration filter is applied by dividing pixel by pixel a portal image by its blurred version. In the second step, named Lineally Combined Local Histogram Equalization (LCLHE), the contrast of the original image is strongly improved by a Local Contrast Enhancement (LCE) algorithm, revealing the anatomical structures of patients. The output image is lineally combined with a portal image of the patient. Finally the output images of the previous algorithms (NLM and LCLHE) are lineally combined, once again, in order to obtain a contrast enhanced image. These two algorithms have been tested on several portal images with great results. - Highlights: • Two Algorithms are implemented to improve the contrast of Electronic Portal Images. • The multi-leaf and conformed beam are automatically segmented into Portal Images. • Hidden anatomical and bony structures in portal images are revealed. • The task related to the patient setup verification is facilitated by the contrast enhancement then achieved.

  16. Vascular patterns in nodules of intraductal papillary mucinous neoplasms depicted under contrast-enhanced ultrasonography are helpful for evaluating malignant potential

    International Nuclear Information System (INIS)

    Kurihara, Naoko; Kawamoto, Hirofumi; Kobayashi, Yoshiyuki; Okamoto, Yuko; Yamamoto, Naoki; Tsutsumi, Koichiro; Fujii, Masakuni; Kato, Hironari; Yamamoto, Kazuhide

    2012-01-01

    Objectives: The purpose of this study is to evaluate the feasibility of contrast-enhanced ultrasonography (CE-US) to differentiate between benign and malignant intraductal papillary mucinous neoplasms (IPMN). Patients and methods: Contrast-enhanced ultrasonography with a contrast agent was performed on 22 consecutive patients with IPMN suspected of being malignant. This revealed 10 carcinomas, 1 borderline lesion and 11 adenomas. All patients underwent surgery, and the histological diagnosis was confirmed by examination of resected specimens. CE-US was performed using a contrast agent. The detection rates of mural nodules were compared between CE-US and contrast-enhanced computed tomography (CE-CT), and the imaging of mural nodules depicted under CE-US was analyzed. Results: Seventeen of 22 resected specimens (77.3%) had mural nodules. There was no significant difference in the detection rate between CE-US (n = 15; 88.2%) and CE-CT (n = 12; 70.6%). In 12 (80.0%) of these patients, CE-US revealed small vessels in the mural nodule. The spotty or linear-shaped pattern was detected in 4 patients and the branch-shaped pattern in 8. The branch-shaped pattern lesion was associated with carcinoma. These mural nodules were 10 mm or more in height. In the perfusion image phase, cystic walls and mural nodules were also enhanced in all cases. Conclusion: The vessel shapes of the mural nodules depicted under CE-US were associated with size and pathological findings. These results suggested that CE-US with a contrast agent is a powerful modality with which to evaluate the malignant potential of IPMN.

  17. Diagnostic accuracy of unenhanced, contrast-enhanced perfusion and angiographic MRI sequences for pulmonary embolism diagnosis: results of independent sequence readings

    Energy Technology Data Exchange (ETDEWEB)

    Revel, Marie Pierre [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Hotel-Dieu, Service de Radiologie, Paris (France); Sanchez, Olivier; Meyer, Guy [Hopital Europeen Georges Pompidou, APHP, Respiratory and intensive care and, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM Unite 765, Paris (France); Lefort, Catherine; Couchon, Sophie; Hernigou, Anne; Frija, Guy [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Niarra, Ralph [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Chatellier, Gilles [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM CIC-EC E4, Paris (France)

    2013-09-15

    To independently evaluate unenhanced, contrast-enhanced perfusion and angiographic MR sequences for pulmonary embolism (PE) diagnosis. Prospective investigation, including 274 patients who underwent perfusion, unenhanced 2D steady-state-free-precession (SSFP) and contrast-enhanced 3D angiographic MR sequences on a 1.5-T unit, in addition to CTA (CT angiography). Two independent readers evaluated each sequence independently in random order. Sensitivity, specificity, predictive values and inter-reader agreement were calculated for each sequence, excluding sequences judged inconclusive. Sensitivity was also calculated according to PE location. Contrast-enhanced angiographic sequences showed the highest sensitivity (82.9 and 89.7 %, reader 1 and reader 2, respectively), specificity (98.5 and 100 %) and agreement (kappa value 0.77). Unenhanced angiographic sequences, although less sensitive overall (68.7 and 76.4 %), were sensitive for the detection of proximal PE (92.7 and 100 %) and showed high specificity (96.1 and 99.1 %) and good agreement (kappa value 0.62). Perfusion sequences showed lower sensitivity (75.0 and 79.3 %), specificity (84.8 and 89.7 %) and agreement (kappa value 0.51), and a negative predictive value of 84.8 % at best. Compared with contrast-enhanced angiographic sequences, unenhanced sequences demonstrate lower sensitivity, except for proximal PE, but high specificity and agreement. The negative predictive value of perfusion sequences was insufficient to safely rule out PE. (orig.)

  18. Dynamic contrast-enhanced CT in advanced lung cancer after chemotherapy with/within radiation therapy: Can it predict treatment responsiveness of the tumor?

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Mi Ri; Whang, Sung Ho; Park, Chul Hwan; Kim, Sang Jin; Kim, Tae Hoon [Dept. of Radiology and Research Institute of Radiological Science, Yonsei University Health System, Seoul (Korea, Republic of)

    2013-08-15

    To evaluate the contrast enhancement patterns of lung cancer after chemotherapy using a dynamic contrast-enhanced (DCE) CT and to determine whether the enhancement patterns of tumors at early stages of treatment can predict treatment responses. Forty-two patients with advanced lung cancers underwent DCE-CT and follow-up CT after chemotherapy. We evaluated peak and net enhancement (PE and NE, respectively) and time-density curves (TDCs) (type A, B, C, and D) on DCE-CT images. Treatment responses were evaluated using revised Response Evaluation Criteria in Solid Tumor criteria. NE and PE values were significantly higher in the progressive disease (PD) groups than in the stable disease (SD) or partial response (PR) groups (p < 0.05). Types B, C, and D on TDCs were observed mostly in the PR and SD groups (96.0%), whereas type A was most frequent in the SD and PD groups (97.2%), which were significantly different in terms of PE and NE. Contrast enhancement pattern regarding the response of treatment on DCE-CT images could be helpful in predicting treatment response of advanced lung cancer after treatment.

  19. Contrast-enhanced ultrasound for extrahepatic lesions: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Thorelius, Lars E-mail: lars@thorelius.com

    2004-06-01

    Ultrasound imaging (US) is a convenient, inexpensive and non-invasive investigation. Its use is limited by low sensitivity in the detection of a number of parenchymal lesions, especially those produced by trauma, such as infarctions. Contrast enhancement with SonoVue{sup [reg]} improves the sensitivity of ultrasound in the detection and characterization of focal liver lesions to such an extent, that it may replace computed tomography (CT) and magnetic resonance imaging (MRI). Preliminary experience suggests that SonoVue-enhanced sonography may be useful in the detection of lesions in which blood flow is severely reduced as compared to surrounding parenchyma, such as infarctions, lacerations, hematomas, necrotic tissue and non-vascular cysts, especially in the spleen, kidney and pancreas. This technique can also rule out occlusion of the superior mesenteric, splenic and portal veins, and dilation of the biliary tree. Clinical trials comparing contrast-enhanced sonography with contrast-enhanced computed tomography are warranted to establish the role of this inexpensive and non-invasive technique in the routine work-up of patients with abdominal trauma or presenting with sudden flank pain.

  20. The added value of 68Ga-DOTA-TATE-PET to contrast-enhanced CT for primary site detection in CUP of neuroendocrine origin.

    Science.gov (United States)

    Kazmierczak, Philipp M; Rominger, Axel; Wenter, Vera; Spitzweg, Christine; Auernhammer, Christoph; Angele, Martin K; Rist, Carsten; Cyran, Clemens C

    2017-04-01

    To quantify the additional value of 68 Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced 68 Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and 68 Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up 68 Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. • 68 Ga-DOTA-TATE PET augments the sensitivity of contrast-enhanced CT by 50 % • 68 Ga-DOTA-TATE PET augments the accuracy of contrast-enhanced CT by 30 % • Somatostatin receptor-targeted hybrid imaging optimizes primary tumour detection in CUP-NET.

  1. BMD measurements of the spine derived from sagittal reformations of contrast-enhanced MDCT without dedicated software

    Energy Technology Data Exchange (ETDEWEB)

    Baum, Thomas, E-mail: thbaum@gmx.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Mueller, Dirk, E-mail: dirk.mueller@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Dobritz, Martin, E-mail: dobritz@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Rummeny, Ernst J., E-mail: institut@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany); Link, Thomas M., E-mail: thomas.link@radiology.ucsf.edu [Musculoskeletal and Quantitative Imaging Research, Department of Radiology and Biomedical Imaging, University of California San Francisco, 185 Berry Street, Suite 350, San Francisco, CA 94107 (United States); Bauer, Jan S., E-mail: jsb@roe.med.tum.de [Institut fuer Roentgendiagnostik, Klinikum rechts der Isar, Technische Universitaet Muenchen, Ismaninger Str. 22, 81675 Muenchen (Germany)

    2011-11-15

    Purpose: To assess QCT equivalent BMD of the lumbar spine in sagittal reformations of routine abdominal contrast-enhanced MDCT with simple PACS measurement tools and to apply this method to MDCT datasets for differentiating patients with and without osteoporotic vertebral fractures. Materials and methods: Eight postmenopausal women (65 {+-} 5years) underwent standard QCT to assess BMD of L1-L3. Afterwards routine abdominal contrast-enhanced MDCT images of these women were obtained and apparent BMD of L1-L3 was measured using the sagittal reformations. The MDCT-to-QCT conversion equation for BMD was calculated with linear regression analysis. The conversion equation was applied to vertebral BMD datasets (L1-L3) of 75 postmenopausal women (66 {+-} 4years). Seventeen of the 75 patients had osteoporotic vertebral fractures. Results: BMD values of contrast-enhanced MDCT were on average 56 mg/ml higher than those of standard QCT. A correlation coefficient of r = 0.94 (p < 0.05) was calculated for the BMD values of MDCT and standard QCT with the conversion equation BMD{sub QCT} = 0.69 x BMD{sub MDCT} - 11 mg/ml. Accordingly converted BMD values of patients with vertebral fractures were significantly lower than those of patients without vertebral fractures (69 mg/ml vs. 85 mg/ml; p < 0.05). Using ROC analysis to differentiate patients with and without vertebral fractures, AUC = 0.72 was obtained for converted BMD values (p < 0.05). Short- and long-term reproducibility errors for BMD measurements in the sagittal reformations amounted 2.09% and 7.70%, respectively. Conclusion: BMD measurements of the spine could be computed in sagittal reformations of routine abdominal contrast-enhanced MDCT with minimal technical and time effort. Using the conversion equation, the acquired BMD data could differentiate patients with and without osteoporotic vertebral fractures.

  2. Usefulness of three-dimensional contrast-enhanced MR angiography in the evaluation of pelvic and lower extremity arteries

    International Nuclear Information System (INIS)

    Kim, Young Kon; Han, Young Min; Lee, Jeong Min

    2002-01-01

    To evaluate the feasibility and clinical usefulness of three-dimensional contrast-enhanced MR angiography (3D-CE-MRA) as a screening test in the evaluation of pelvic and lower extremity arterial diseases. Forty-four patients who underwent 3D-CE-MRA were included in this study. Coronal 3-dimensional gradient-echo, pre-and post contrast image were acquired with a dedicated peripheral vascular coil and moving-bed technique on a 1.5T MR system. Timing of start of data acquisition was determined by MR fluoroscopy technique, and 0.2 mmol/kg Gd-DTPA was injected into an antecubital vein, at a rate of 1cc/sec with an autoinjector. For quantitative analysis, signal to noise ratio (SNR) and artery to soft tissue contrast to noise ratio (CNR) of lower extremities arterial system including lower abdominal aorta were calculated. For qualitative analysis, arterial systems were divided into six segments, and were evaluated in terms of conspicuity of arterial systems and the degree of venous enhancement by three- and four-point scale respectively. In eight patients who underwent both MR angiography and conventional angiography as standard reference. Imaging analysis was done by means of consensus between two experienced radiologists. The mean time for the examination was about 15 min (± 5 min). The mean SNR of arterial system was 26.5±11.6, and mean artery to soft tissue contrast to noise ratio (CNR) was 24.6±11.2. Among the total 525 arterial segments 498 arterial segments (94.5%) could be demonstrated with good delineation of entire arterial tree. Good arterial imaging without or with minimal venous enhancement were demonstrated in 98.5% (260/264) in above knee and 89% (211/261) in below knee (p<0.01). Ten of 525 segments (1.9%) demonstrated severe venous overlapping and it mostly occurred in the calf region. In comparison with DSA, the sensitivity and the specificity for MR angiography for the detection of occlusions were 96% and 98.8%, respectively, and for the detection of

  3. Confident Diagnosis of Bronchobiliary Fistula Using Contrast-Enhanced Magnetic Resonance Cholangiography

    Energy Technology Data Exchange (ETDEWEB)

    Karabulut, Nevzat; Cakmak, Vefa; Kiter, Go ksel [Pamukkale University Medical Center, Denizli (Turkmenistan)

    2010-08-15

    We report the utility of contrast-enhanced magnetic resonance cholangiography (MRC) using gadoxetic acid (Gd-EOB-DTPA) in the diagnosis of bronchobiliary fistula associated with liver hydatid cyst. Contrast-enhanced MRC clearly delineated the leakage of contrast agent from the biliary duct and its communication with the bronchial tree. Providing functional information about physiologic or pathologic biliary flow in addition to the display of biliary anatomy, contrast enhanced MRC stands as a robust technique in confidently detecting bronchobiliary fistula and bile leaks

  4. Application of histogram analysis for the evaluation of vascular permeability in glioma by the K2 parameter obtained with the dynamic susceptibility contrast method: Comparisons with Ktrans obtained with the dynamic contrast enhance method and cerebral blood volume.

    Science.gov (United States)

    Taoka, Toshiaki; Kawai, Hisashi; Nakane, Toshiki; Hori, Saeka; Ochi, Tomoko; Miyasaka, Toshiteru; Sakamoto, Masahiko; Kichikawa, Kimihiko; Naganawa, Shinji

    2016-09-01

    The "K2" value is a factor that represents the vascular permeability of tumors and can be calculated from datasets obtained with the dynamic susceptibility contrast (DSC) method. The purpose of the current study was to correlate K2 with Ktrans, which is a well-established permeability parameter obtained with the dynamic contrast enhance (DCE) method, and determine the usefulness of K2 for glioma grading with histogram analysis. The subjects were 22 glioma patients (Grade II: 5, III: 6, IV: 11) who underwent DSC studies, including eight patients in which both DSC and DCE studies were performed on separate days within 10days. We performed histogram analysis of regions of interest of the tumors and acquired 20th percentile values for leakage-corrected cerebral blood volume (rCBV20%ile), K2 (K220%ile), and for patients who underwent a DCE study, Ktrans (Ktrans20%ile). We evaluated the correlation between K220%ile and Ktrans20%ile and the statistical difference between rCBV20%ile and K220%ile. We found a statistically significant correlation between K220%ile and Ktrans20%ile (r=0.717, pK220%ile showed a statistically significant (pK2 value calculated from the DSC dataset, which can be obtained with a short acquisition time, showed a correlation with Ktrans obtained with the DCE method and may be useful for glioma grading when analyzed with histogram analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Semi-automatic motion compensation of contrast-enhanced ultrasound images from abdominal organs for perfusion analysis

    Czech Academy of Sciences Publication Activity Database

    Schafer, S.; Nylund, K.; Saevik, F.; Engjom, T.; Mézl, M.; Jiřík, Radovan; Dimcevski, G.; Gilja, O.H.; Tönnies, K.

    2015-01-01

    Roč. 63, AUG 1 (2015), s. 229-237 ISSN 0010-4825 R&D Projects: GA ČR GAP102/12/2380 Institutional support: RVO:68081731 Keywords : ultrasonography * motion analysis * motion compensation * registration * CEUS * contrast-enhanced ultrasound * perfusion * perfusion modeling Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 1.521, year: 2015

  6. Dynamic contrast-enhanced breast MRI at 7 Tesla utilizing a single-loop coil: a feasibility trial.

    Science.gov (United States)

    Umutlu, Lale; Maderwald, Stefan; Kraff, Oliver; Theysohn, Jens M; Kuemmel, Sherko; Hauth, Elke A; Forsting, Michael; Antoch, Gerald; Ladd, Mark E; Quick, Harald H; Lauenstein, Thomas C

    2010-08-01

    The aim of this study was to assess the feasibility of dynamic contrast-enhanced ultra-high-field breast imaging at 7 Tesla. A total of 15 subjects, including 5 patients with histologically proven breast cancer, were examined on a 7 Tesla whole-body magnetic resonance imaging system using a unilateral linearly polarized single-loop coil. Subjects were placed in prone position on a biopsy support system, with the coil placed directly below the region of interest. The examination protocol included the following sequences: 1) T2-weighted turbo spin echo sequence; 2) six dynamic T1-weighted spoiled gradient-echo sequences; and 3) subtraction imaging. Contrast-enhanced T1-weighted imaging at 7 Tesla could be obtained at high spatial resolution with short acquisition times, providing good image accuracy and a conclusively good delineation of small anatomical and pathological structures. T2-weighted imaging could be obtained with high spatial resolution at adequate acquisition times. Because of coil limitations, four high-field magnetic resonance examinations showed decreased diagnostic value. This first scientific approach of dynamic contrast-enhanced breast magnetic resonance imaging at 7 Tesla demonstrates the complexity of ultra-high-field breast magnetic resonance imaging and countenances the implementation of further advanced bilateral coil concepts to circumvent current limitations from the coil and ultra-high-field magnetic strength. 2010 AUR. Published by Elsevier Inc. All rights reserved.

  7. Image fusion in dual energy computed tomography for detection of various anatomic structures - Effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Jijo, E-mail: jijopaul1980@gmail.com [Department of Diagnostic Radiology, Goethe University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Department of Biophysics, Goethe University, Max von Laue-Str.1, 60438 Frankfurt am Main (Germany); Bauer, Ralf W. [Department of Diagnostic Radiology, Goethe University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany); Maentele, Werner [Department of Biophysics, Goethe University, Max von Laue-Str.1, 60438 Frankfurt am Main (Germany); Vogl, Thomas J. [Department of Diagnostic Radiology, Goethe University Hospital, Theodor-Stern-Kai 7, 60590 Frankfurt am Main (Germany)

    2011-11-15

    Objective: The purpose of this study was to evaluate image fusion in dual energy computed tomography for detecting various anatomic structures based on the effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality. Material and methods: Forty patients underwent a CT neck with dual energy mode (DECT under a Somatom Definition flash Dual Source CT scanner (Siemens, Forchheim, Germany)). Tube voltage: 80-kV and Sn140-kV; tube current: 110 and 290 mA s; collimation-2 x 32 x 0.6 mm. Raw data were reconstructed using a soft convolution kernel (D30f). Fused images were calculated using a spectrum of weighting factors (0.0, 0.3, 0.6 0.8 and 1.0) generating different ratios between the 80- and Sn140-kV images (e.g. factor 0.6 corresponds to 60% of their information from the 80-kV image, and 40% from the Sn140-kV image). CT values and SNRs measured in the ascending aorta, thyroid gland, fat, muscle, CSF, spinal cord, bone marrow and brain. In addition, CNR values calculated for aorta, thyroid, muscle and brain. Subjective image quality evaluated using a 5-point grading scale. Results compared using paired t-tests and nonparametric-paired Wilcoxon-Wilcox-test. Results: Statistically significant increases in mean CT values noted in anatomic structures when increasing weighting factors used (all P {<=} 0.001). For example, mean CT values derived from the contrast enhanced aorta were 149.2 {+-} 12.8 Hounsfield Units (HU), 204.8 {+-} 14.4 HU, 267.5 {+-} 18.6 HU, 311.9 {+-} 22.3 HU, 347.3 {+-} 24.7 HU, when the weighting factors 0.0, 0.3, 0.6, 0.8 and 1.0 were used. The highest SNR and CNR values were found in materials when the weighting factor 0.6 used. The difference CNR between the weighting factors 0.6 and 0.3 was statistically significant in the contrast enhanced aorta and thyroid gland (P = 0.012 and P = 0.016, respectively). Visual image assessment for image quality showed the highest score for the data reconstructed using the

  8. Image fusion in dual energy computed tomography for detection of various anatomic structures - Effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality

    International Nuclear Information System (INIS)

    Paul, Jijo; Bauer, Ralf W.; Maentele, Werner; Vogl, Thomas J.

    2011-01-01

    Objective: The purpose of this study was to evaluate image fusion in dual energy computed tomography for detecting various anatomic structures based on the effect on contrast enhancement, contrast-to-noise ratio, signal-to-noise ratio and image quality. Material and methods: Forty patients underwent a CT neck with dual energy mode (DECT under a Somatom Definition flash Dual Source CT scanner (Siemens, Forchheim, Germany)). Tube voltage: 80-kV and Sn140-kV; tube current: 110 and 290 mA s; collimation-2 x 32 x 0.6 mm. Raw data were reconstructed using a soft convolution kernel (D30f). Fused images were calculated using a spectrum of weighting factors (0.0, 0.3, 0.6 0.8 and 1.0) generating different ratios between the 80- and Sn140-kV images (e.g. factor 0.6 corresponds to 60% of their information from the 80-kV image, and 40% from the Sn140-kV image). CT values and SNRs measured in the ascending aorta, thyroid gland, fat, muscle, CSF, spinal cord, bone marrow and brain. In addition, CNR values calculated for aorta, thyroid, muscle and brain. Subjective image quality evaluated using a 5-point grading scale. Results compared using paired t-tests and nonparametric-paired Wilcoxon-Wilcox-test. Results: Statistically significant increases in mean CT values noted in anatomic structures when increasing weighting factors used (all P ≤ 0.001). For example, mean CT values derived from the contrast enhanced aorta were 149.2 ± 12.8 Hounsfield Units (HU), 204.8 ± 14.4 HU, 267.5 ± 18.6 HU, 311.9 ± 22.3 HU, 347.3 ± 24.7 HU, when the weighting factors 0.0, 0.3, 0.6, 0.8 and 1.0 were used. The highest SNR and CNR values were found in materials when the weighting factor 0.6 used. The difference CNR between the weighting factors 0.6 and 0.3 was statistically significant in the contrast enhanced aorta and thyroid gland (P = 0.012 and P = 0.016, respectively). Visual image assessment for image quality showed the highest score for the data reconstructed using the weighting factor 0

  9. Cranial CT revisited: do we really need contrast enhancement?

    International Nuclear Information System (INIS)

    Demaerel, P.; Buelens, C.; Wilms, G.; Baert, A.L.

    1998-01-01

    The aim of this study was to define guidelines for intravenous contrast administration in cranial CT, as currently there are no recent guidelines based on a large series of patients. In 1900 consecutive patients (1480 adults and 420 children) pre- and post-contrast scan was analysed in order to assess the contribution of contrast enhancement to the diagnosis. The findings were grouped according to whether abnormalities were seen on the pre- and/or post-contrast scan, or whether no abnormalities were seen at all. Sensitivity, specificity, positive predictive value, negative predictive value and accurracy of a pre-contrast scan were used to determine validity. Intravenous contrast enhancement only contributes to the diagnosis if a suspicious abnormality is seen on the unenhanced scan or in the appropriate clinical setting (33.6 %). In the remaining patients (65.6 %) there is no diagnostic contribution, except for a small number of abnormalities (0.8 %). These are often anatomical variants and have no therapeutic impact. The number of contrast-enhanced cranial CT examinations can significantly be reduced by using four general guidelines for contrast administration resulting in considerable cost savings without affecting the quality of service to the patient. These guidelines are defined by the clinical findings/presentation or by the findings on the unenhanced scan. The number of contrast-related complications will be reduced, which may have medicolegal implications. These guidelines can be applied in any radiology department. (orig.) (orig.)

  10. Dynamic contrast-enhanced magnetic resonance imaging of radiation therapy-induced microcirculation changes in rectal cancer

    International Nuclear Information System (INIS)

    Lussanet, Quido G. de; Backes, Walter H.; Griffioen, Arjan W.; Padhani, Anwar R.; Baeten, Coen I.; Baardwijk, Angela van; Lambin, Philippe; Beets, Geerard L.; Engelshoven, Jos van; Beets-Tan, Regina G.H.

    2005-01-01

    Purpose: Dynamic contrast-enhanced T1-weighted magnetic resonance imaging (DCE-MRI) allows noninvasive evaluation of tumor microvasculature characteristics. This study evaluated radiation therapy related microvascular changes in locally advanced rectal cancer by DCE-MRI and histology. Methods and Materials: Dynamic contrast-enhanced-MRI was performed in 17 patients with primary rectal cancer. Seven patients underwent 25 fractions of 1.8 Gy radiation therapy (RT) (long RT) before DCE-MRI and 10 did not. Of these 10, 3 patients underwent five fractions of 5 Gy RT (short RT) in the week before surgery. The RT treated and nontreated groups were compared in terms of endothelial transfer coefficient (K PS , measured by DCE-MRI), microvessel density (MVD) (scored by immunoreactivity to CD31 and CD34), and tumor cell and endothelial cell proliferation (scored by immunoreactivity to Ki67). Results: Tumor K PS was 77% (p = 0.03) lower in the RT-treated group. Histogram analyses showed that RT reduced both magnitude and intratumor heterogeneity of K PS (p = 0.01). MVD was significantly lower (37%, p 0.03) in tumors treated with long RT than in nonirradiated tumors, but this was not the case with short RT. Endothelial cell proliferation was reduced with short RT (81%, p = 0.02) just before surgery, but not with long RT (p > 0.8). Tumor cell proliferation was reduced with both long (57%, p PS values showed significant radiation therapy related reductions in microvessel blood flow in locally advanced rectal cancer. These findings may be useful in evaluating effects of radiation combination therapies (e.g., chemoradiation or RT combined with antiangiogenesis therapy), to account for effects of RT alone

  11. Low osmolar (non-ionic) contrast media versus high osmolar (ionic) contrast media in intravenous urography and enhanced computerized tomography: a cost-effectiveness analysis.

    Science.gov (United States)

    Wangsuphachart, S

    1991-12-01

    The cost-effectiveness of three alternative policies for the use of intravenous contrast media for urography and enhanced computerized tomography (CT) are analyzed. Alternative #1 is to use high osmolar contrast media (HOCM) in all patients, the historical policy. Alternative #2 is to replace it with low osmolar contrast media (LOCM) in all patients. Alternative #3 is to use LOCM only in the high risk patients. Data on the 6,242 patients who underwent intravenous urography and enhanced CT at the Department of Radiology, Chulalongkorn Hospital in 1989 were used. Both societal and hospital viewpoints were analyzed. The incremental cost-effectiveness (ICE) between #2 and #1 was 26,739 Baht (US$1,070) per healthy day saved (HDS), while the ICE between #3 and #1 was 12,057 Baht (US$482) per HDS. For fatal cases only, ICE between #2 and #1 was 35,111 Baht (US$1,404) per HDS, while the ICE between #3 and #1 was 18,266 Baht (US$731) per HDS. The incremental cost (IC) per patient was 2,341 Baht (US$94) and 681 Baht (US$27) respectively. For the hospital viewpoint the ICE between #2 and #1 was 13,744 (US$550) and between #3 and #1 was 6,127 Baht (US$245) per HDS. The IC per patient was 1,203 Baht (US$48) and 346 Baht (US$14), respectively. From the sensitivity analysis, #3 should be used if the LOCM price is reduced more than 75% (equal to 626 Baht or less) and more than 80% of the patients are able to pay for the contrast media.

  12. Dynamic contrast-enhanced MRI of benign prostatic hyperplasia and prostatic carcinoma: correlation with angiogenesis

    International Nuclear Information System (INIS)

    Ren, J.; Huan, Y.; Wang, H.; Chang, Y.-J.; Zhao, H.-T.; Ge, Y.-L.; Liu, Y.; Yang, Y.

    2008-01-01

    Aim: To investigate the diagnostic and differential diagnostic values of dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) in prostatic diseases, and to investigate the correlation between the parameters of SI-T curves and angiogenesis. Materials and methods: Twenty-one patients with proven prostatic carcinoma (Pca) and 29 patients with proven benign prostatic hyperplasia (BPH) were examined using DCE MRI. Diagnostic characteristics for differentiation were examined using threshold values for maximum peak time, enhancement degree, and enhancement rate. Then, the signal intensity-time curves (SI-T curves) were analysed, and the correlations between the parameters of SI-T curves and the expression levels of vascular endothelial growth factor (VEGF) and microvascular density (MVD) were investigated. All patients underwent prostatectomy. DCE MRI and histological findings were correlated. Results: Pca showed stronger enhancement with an earlier peak time, higher enhancement, and enhancement rate (p 2 = 13.57, P < 0.005). The VEGF and MVD expression levels of Pca were higher than those of BPH. Peak time was negatively correlated with the expression levels of VEGF and MVD, whereas the enhancement degree and enhancement rate showed positive correlations (Pearson correlation, p < 0.05). Conclusion: Based on T2-weighted imaging, DCE MRI curves can help to differentiate benign from malignant prostate tissue. In the present study the type C curve was rarely seen with malignant disease, but these results need confirmation

  13. Is dynamic contrast-enhanced MRI useful for assessing proximal fragment vascularity in scaphoid fracture delayed and non-union?

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Alex W.H.; Griffith, James F.; Li, Alvin [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince of Wales Hospital, Hong Kong, SAR (China); Taljanovic, Mihra S. [The University of Arizona Health Network, Department of Medical Imaging, 1501 N. Campbell Ave., P.O. Box 245067, Tucson, AZ (United States); Tse, W.L.; Ho, P.C. [The Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince of Wales Hospital, Hong Kong (China)

    2013-07-15

    To assess dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) as a measure of vascularity in scaphoid delayed-union or non-union. Thirty-five patients (34 male, one female; mean age, 27.4 {+-} 9.4 years; range, 16-51 years) with scaphoid delayed-union and non-union who underwent DCE MRI of the scaphoid between September 2002 and October 2012 were retrospectively reviewed. Proximal fragment vascularity was classified as good, fair, or poor on unenhanced MRI, contrast-enhanced MRI, and DCE MRI. For DCE MRI, enhancement slope, E{sub slope} comparison of proximal and distal fragments was used to classify the proximal fragment as good, fair, or poor vascularity. Proximal fragment vascularity was similarly graded at surgery in all patients. Paired t test and McNemar test were used for data comparison. Kappa value was used to assess level of agreement between MRI findings and surgical findings. Twenty-five (71 %) of 35 patients had good vascularity, four (11 %) had fair vascularity, and six (17 %) had poor vascularity of the proximal scaphoid fragment at surgery. DCE MRI parameters had the highest correlation with surgical findings (kappa = 0.57). Proximal scaphoid fragments with surgical poor vascularity had a significantly lower E{sub max} and E{sub slope} than those with good vascularity (p = 0.0043 and 0.027). The sensitivity, specificity, positive and negative predictive value and accuracy of DCE MRI in predicting impaired vascularity was 67, 86, 67, 86, and 80 %, respectively, which was better than that seen with unenhanced and post-contrast MRI. Flattened time intensity curves in both proximal and distal fragments were a feature of protracted non-union with a mean time interval of 101.6 {+-} 95.5 months between injury and MRI. DCE MRI has a higher diagnostic accuracy than either non-enhanced MRI or contrast enhanced MRI for assessing proximal fragment vascularity in scaphoid delayed-union and non-union. For proper interpretation of contrast-enhanced

  14. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    International Nuclear Information System (INIS)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon

    1994-01-01

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days

  15. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon [Inje University College of Medicine, Pusan (Korea, Republic of)

    1994-08-15

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days.

  16. Contrast-Enhanced Ultrasound in Vascular Surgery

    DEFF Research Database (Denmark)

    Bredahl, Kim; Mestre, Xavier Marti; Coll, Ramon Vila

    2017-01-01

    modalities. Ultrasound has only challenged these methods in assessment of carotid disease, aortic aneurysms, venous insufficiency, and thromboembolism and in surveillance of in situ bypasses. These practice patterns may change with the introduction of second-generation ultrasound contrast agents which...... are easy to use, manageable, and safe. This topical review attempts to summarize and highlight the current evidence and future prospects for contrast-enhanced ultrasound in vascular surgery, with a particular focus on opportunities in carotid and lower limb arteriosclerotic disease and surveillance after...

  17. Could parenchymal enhancement on contrast-enhanced spectral mammography (CESM) represent a new breast cancer risk factor? Correlation with known radiology risk factors.

    Science.gov (United States)

    Savaridas, S L; Taylor, D B; Gunawardana, D; Phillips, M

    2017-12-01

    To compare background parenchymal enhancement (BPE) on contrast-enhanced (CE) spectral mammography (CESM) with CE magnetic resonance imaging (MRI), and evaluate how these relate to hormonal status, mammographic breast density (MBD) and MRI fibroglandular tissue volume (FGTV). Between June 2012 to October 2015, participants in a cancer staging study underwent full-field digital mammography (FFDM), CEMRI, and CESM. Two readers independently rated FGTV, MBD, and BPE using the Breast Imaging-Reporting and Data System (BI-RADS) criteria. Inter-reader reliability was estimated using weighted kappa (k) and correlations between BPE, MBD, and FGTV calculated using Spearman's correlation coefficient. Associations with hormonal status were evaluated using multilevel ordinal regression analysis. Of the 96 eligible participants, 66 women (35-77 years) underwent CESM and CEMRI. Reasons for exclusion were declined or withdrawn consent (n=18), inadequate renal function (n=2), claustrophobia (n=2), previous reaction to contrast medium (n=2), mild reaction to contrast medium following CESM (n=2), lack of vascular access (n=1), neoadjuvant chemotherapy (n=1), CESM equipment failure (n=1), and unclear in one case. Inter-reader agreement was substantial (k=0.67) for CESM BPE, slight (k=0.19) for CEMRI BPE, moderate (k=0.57) for MRI FGTV and fair (k=0.35) for MBD. CESM BPE showed significant correlation with MBD (rho=0.36, p<0.0001), FGTV (rho=0.52, p<0.0001), and MRI BPE (rho=0.49, p<0.0001). BPE was significantly reduced in the post-menopausal group for CEMRI and CESM (p<0.05). CESM BPE did not significantly fluctuate during the menstrual cycle. CESM BPE is correlated with MBD, FGTV, and CEMRI BPE, has better inter-reader reliability than CEMRI, and is not influenced by the menstrual cycle. Grading the degree of BPE on CESM could be a useful addition to breast cancer risk assessment tools. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights

  18. Evaluation of subject contrast and normalized average glandular dose by semi-analytical models

    International Nuclear Information System (INIS)

    Tomal, A.; Poletti, M.E.; Caldas, L.V.E.

    2010-01-01

    In this work, two semi-analytical models are described to evaluate the subject contrast of nodules and the normalized average glandular dose in mammography. Both models were used to study the influence of some parameters, such as breast characteristics (thickness and composition) and incident spectra (kVp and target-filter combination) on the subject contrast of a nodule and on the normalized average glandular dose. From the subject contrast results, detection limits of nodules were also determined. Our results are in good agreement with those reported by other authors, who had used Monte Carlo simulation, showing the robustness of our semi-analytical method.

  19. Improvement of observer performance during fluoroscopy by local adaptive contrast enhancement

    International Nuclear Information System (INIS)

    Gould, R.G.; Demas, B.E.; Maroney, T.P.

    1988-01-01

    The ability of a video processor (FluoroVision FV-1), which performs two-dimensional locally adaptive contrast enhancement, to improve the detection of a low-contrast object was evaluated by means of receiver operating characteristic (ROC) curves. Three independent observers viewed a videotape of 50 fluoroscopic images of a varied background, in which a test object was present in 25. Each observer viewed the tape under four conditions: (1) no processing, (2) temporal noise reduction (gaussian weighted time averaging, (3) contrast enhancement, and (4) both noise reduction and contrast enhancement. The results were that detection was significantly improved by the locally adaptive contrast enhancement. Noise reduction did not significantly improve performance, probably because washer detection was limited by background contrast variations as well as noise and because only a small amount of noise reduction was used. The authors conclude that the processing device is potentially valuable in improving the quality of clinical fluoroscopic images

  20. A novel nitroreductase-enhanced MRI contrast agent and its potential application in bacterial imaging

    Directory of Open Access Journals (Sweden)

    Yun Liu

    2018-05-01

    Full Text Available Nitroreductases (NTRs are known to be able to metabolize nitro-substituted compounds in the presence of reduced nicotinamide adenine dinucleotide (NADH as an electron donor. NTRs are present in a wide range of bacterial genera and, to a lesser extent, in eukaryotes hypoxic tumour cells and tumorous tissues, which makes it an appropriate biomarker for an imaging target to detect the hypoxic status of cancer cells and potential bacterial infections. To evaluate the specific activation level of NTR, great efforts have been devoted to the development of fluorescent probes to detect NTR activities using fluorogenic methods to probe its behaviour in a cellular context; however, NTR-responsive MRI contrast agents are still by far underexplored. In this study, para-nitrobenzyl substituted T1-weighted magnetic resonance imaging (MRI contrast agent Gd-DOTA-PNB (probe 1 has been designed and explored for the possible detection of NTR. Our experimental results show that probe 1 could serve as an MRI-enhanced contrast agent for monitoring NTR activity. The in vitro response and mechanism of the NTR catalysed reduction of probe 1 have been investigated through LC–MS and MRI. Para-nitrobenzyl substituted probe 1 was catalytically reduced by NTR to the intermediate para-aminobenzyl substituted probe which then underwent a rearrangement elimination reaction to Gd-DOTA, generating the enhanced T1-weighted MR imaging. Further, LC–MS and MRI studies of living Escherichia coli have confirmed the NTR activity detection ability of probe 1 at a cellular level. This method may potentially be used for the diagnosis of bacterial infections. KEY WORDS: Nitroreductase, MRI contrast agent, Smart imaging probes, Bacterial imaging, Bacterial infection

  1. Recent advances in contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Meaney, J.F.M.; Goyen, M.

    2007-01-01

    Magnetic resonance angiography (MRA) provides a means of visualizing vascular structures noninvasively and is increasingly replacing conventional X-ray angiography in routine use. Contrast-enhanced MRA (CE-MRA), in which gadolinium contrast agents are used to shorten the T1 relaxation, offers increased resolution and higher signal-to-noise ratio compared with earlier flow-dependent [time-of-flight (TOF) or phase-contrast (PC)] techniques. Currently available contrast agents differ in their ability to lower T1 values, and hence the choice of contrast agent is an important consideration in the successful use of CE-MRA. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first of a new class of intravascular contrast agents. This agent is extensively (approximately 85%) and reversibly bound to human serum albumin and is retained within the vasculature thus allowing steady-state imaging to be perform-ed. An additional benefit is that gado0fosveset offers higher relaxivity compared with other contrast agents, thus giving a lower blood T1 values which also makes it ideal for first-pass imaging. Clinical trials have consistently shown that gadofosveset enhanced MRA is more sensitive, specific and accurate than time-of-flight MRA, gives fewer uninterpretable scans and affords greater diagnostic confidence. Intravascular contrast agents such as gadofosveset, therefore, offer the potential for improved vascular imaging. (orig.)

  2. Diagnostic Accuracy of Detecting Hashimoto's Thyroiditis in Thyroid Cancer Patients Who Underwent Thyroid Surgery: Comparison of Ultrasonography, Positron Emission Tomography/CT, Contrast Enhanced CT, and Anti-Thyroid Antibody

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Gyun; Lee, Tae Hyun; Park, Dong Hee; Nam, Sang Been [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To compare the diagnostic accuracy of ultrasonography (US), F18-fluorodeoxyglucose positron emission tomography/CT (PET/CT), contrast enhanced CT (CECT), serum anti-thyroid antibody for detecting Hashimoto's thyroiditis in thyroid cancer patients who underwent neck surgery. A total of 150 patients with suspicious for thyroid cancer, who had previously undergone US guided needle aspiration of thyroid, were evaluated with the use of US, PET/CT, CECT and serum anti-thyroid antibody. The four studies were performed within two months before neck surgery. Hashimoto's thyroiditis was confirmed by histopathological results. The diagnostic accuracy of US, PET/CT, CECT and serum anti-thyroid antibody were calculated statistically. Hashimoto's thyroiditis was diagnosed in 51 out of the 150 patients, following neck surgery. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of US were 76.5%, 92.9%, 84.8%, 88.5%, and 87.3%, respectively. The corresponding values of PET/CT were 37.3%, 96.0%, 82.6%, 74.8%, and 76.0%, and CECT were 62.7%, 89.9%, 76.2%, 82.4%, and 80.7%, and serum anti-thyroid antibody level were 90.2%, 93.9%, 88.5%, 94.9%, and 92.7%, respectively. McNemar test revealed significant difference among PET/CT and others, but no significant differences among US, CECT and serum anti-thyroid antibody. Overall, serum anti-thyroid antibody showed most accurate diagnostic performance. In detecting Hashimoto's thyroiditis, serum anti-thyroid antibody showed higher diagnostic accuracy than others. US also showed relatively high diagnostic accuracy.

  3. Contrast-enhanced fast fluid-attenuated inversion recovery MR imaging in patients with brain tumors

    International Nuclear Information System (INIS)

    Kim, Chan Kyo; Na, Dong Gyu; Ryoo, Wook Jae; Byun Hong Sik; Yoon, Hye Kyung; Kim, Jong hyun

    2000-01-01

    To assess the feasibility of contrast-enhanced fast fluid-attenuated inversion recovery (fast FLAIR) MR imaging in patients with brain tumors. This study involved 31 patients with pathologically proven brain tumors and nine with clinically diagnosed metastases. In all patients, T2-weighted, fast FLAIR, images were visual contrast-enhanced T1-weighted MR images were obtained. Contrast-enhanced fast FLAIR images were visually compared with other MR sequences in terms of tumor conspicuity. In order to distinguish tumor and surrounding edema, contrast-enhanced fast FLAIR images were compared with fast FLAIR and T2-weighted images. The tumor-to- white matter contrast-to-noise ratios (CNRs), as demonstrated by T2-weighted, fast FLAIR, contrast-enhanced fast FLAIR and contrast-enhanced T1-weighted imaging, were quantitatively assessed and compared. For the visual assessment of tumor conspicuity, contrast-enhanced fast FLAIR image imaging superior to fast FLAIR in 60% of cases (24/40), and superior to T2-weighted in 70% (28/40). Contrast-enhanced fast FLAIR imaging was inferior to contrast-enhanced T1-weighted in 58% of cases (23/40). For distinguishing between tumor and surrounding edema, contrast-enhanced fast FLAIR imaging was superior to fast FLAIR or T2-weighted in 22 of 27 tumors with peritumoral edema (81%). Quantitatively, CNR was the highest on contrast-enhanced fast FLAIR image and the lowest on fast FLAIR. For the detection of leptomeningeal metastases, contrast-enhanced fast FLAIR was partially superior to contrast-enhanced T1-weighted imaging in two of three high-grade gliomas. Although contrast-enhanced fast FLAIR imaging should not be seen as a replacement for conventional modalities, it provides additional informaton for assessment of the extent of glial cell tumors and leptomeningeal metastases in patients with brain tumors. (author)

  4. Perfusion characteristics of parotid gland tumors evaluated by contrast-enhanced ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Klotz, Laura V., E-mail: Laura.Klotz@med.uni-muenchen.de [Department of Surgery, University of Munich, Munich (Germany); Gürkov, Robert [Department of Otorhinolaryngology, University of Munich, Munich (Germany); Eichhorn, Martin E. [Department of Surgery, University of Munich, Munich (Germany); Siedek, Vanessa; Krause, Eike [Department of Otorhinolaryngology, University of Munich, Munich (Germany); Jauch, Karl-Walter [Department of Surgery, University of Munich, Munich (Germany); Reiser, Maximilian F.; Clevert, Dirk-Andre [Department of Clinical Radiology, University of Munich, Munich (Germany)

    2013-12-01

    Purpose: Contrast enhanced ultrasound (CE-US) is a promising imaging modality for non-invasive analysis of parotid gland lesions because their vascularisation differs from normal gland tissue. This clinical study should further investigate CE-US as a diagnostic tool for parotid gland tumors. Materials and methods: 39 patients underwent CE-US measurements after intravenous application of a contrast agent (SonoVue, Bracco, Italy) before surgical tumor resection. Time–intensity curves gradients were calculated and parameters of intratumoral microcirculation were analysed. The vascularisation parameters were compared among the different tumor entities as defined per definitive histological diagnosis. Results: Histological analyses revealed 17 pleomorphic adenoma, 15 cystadenolymphoma and 7 malignoma. A significant difference of area below intensity time curve (AUC) and mean transit time (MTT) was measured in the malignant lesions compared to benign tumors (p < 0.05). A significant difference of AUC and maximum of signal increase (ΔSI{sub max}) for pleomorphic adenoma versus cystadenolymphoma was found (p < 0.05). Conclusion: CE-US seems to be a quantitative and independent method for the assessment of malign and benign parotid gland tumors. Further studies and clinical experience will have to validate this method as a reliable diagnostic tool that facilitates preoperative planning.

  5. Pancreatic neuroendocrine tumors containing areas of iso- or hypoattenuation in dynamic contrast-enhanced computed tomography: Spectrum of imaging findings and pathological grading.

    Science.gov (United States)

    Hyodo, Ryota; Suzuki, Kojiro; Ogawa, Hiroshi; Komada, Tomohiro; Naganawa, Shinji

    2015-11-01

    To evaluate dynamic contrast-enhanced computed tomography (CT) features of pancreatic neuroendocrine tumors (PNETs) containing areas of iso- or hypoattenuation and the relationship with pathological grading. Between June 2006 and March 2014, 61 PNETs in 58 consecutive patients (29 male, 29 female; median-age 55 years), which were surgically diagnosed, underwent preoperative dynamic contrast-enhanced CT. PNETs were classified based on contrast enhancement patterns in the pancreatic phase: iso/hypo-PNETs were defined as tumors containing areas of iso- or hypoattenuation except for cystic components, and hyper-PNETs were tumors showing hyperattenuation over the whole area. CT findings and contrast-enhancement patterns of the tumors were evaluated retrospectively by two radiologists and compared with the pathological grading. Iso/hypo-PNETs comprised 26 tumors, and hyper-PNETs comprised 35 tumors. Not only hyper-PNETs but also most iso/hypo-PNETs showed peak enhancement in the pancreatic phase and a washout from the portal venous phase to the delayed phase. Iso/hypo-PNETs showed larger tumor size than the hyper-PNETs (mean, 3.7 cm vs. 1.6 cm; PIso/hypo-PNETs also showed significantly higher pathological grading (WHO 2010 classification; iso/hypo, G1=14, G2=11, G3=1; hyper, G1=34, G2=1; Piso/hypo-areas showed a rapid enhancement pattern as well as hyper-PNETs, various radiological features and higher malignant potential. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Role of technetium-99m sestamibi scintimammography and contrast-enhanced magnetic resonance imaging for the evaluation of indeterminate mammograms

    International Nuclear Information System (INIS)

    Tiling, R.; Moser, R.; Meyer, G.; Tatsch, K.; Hahn, K.; Khalkhali, I.; Sommer, H.; Willemsen, F.; Pfluger, T.

    1997-01-01

    This study evaluated and compared technetium-99m sestamibi scintimammography (SMM) and breast magnetic resonance imaging (MRI) results in patients with indeterminate mammograms to determine whether either technique can improve the sensitivity and specificity for the diagnosis of breast carcinoma. From 123 consecutive patients who underwent physical examination, mammography, SMM, and histopathologic confirmation, a subgroup of 82 patients presenting with indeterminate mammograms was studied. Sixty-eight patients underwent contrast-enhanced MRI. SMM results were scored on the basis of the intensity and pattern of sestamibi uptake. MRI images were scored on the basis of signal intensity increase after administration of contrast material as well as the enhancement pattern and speed of gadolinium uptake. The results obtained with the two techniques were compared and related to the final histopathologic diagnoses. Considering indeterminate findings as positive, the sensitivity of SMM was 79% and the specificity, 70%. MRI displayed a sensitivity of 84% and a specificity of 49%. When indeterminate results were considered negative, the sensitivity and specificity of SMM were 62% and 83%, respectively. MRI revealed a sensitivity and specificity of 56% and 79%, respectively. The calculated sensitivities and specificities demonstrate the diagnostic limitations of both SMM and MRI in the evaluation of patients with indeterminate mammographic findings. Due to the higher specificity, SMM may be the preferred modality in the evaluation of selected patients with breast abnormalities. (orig.)

  7. Patterns of contrast enhancement in the brain and meninges.

    Science.gov (United States)

    Smirniotopoulos, James G; Murphy, Frances M; Rushing, Elizabeth J; Rees, John H; Schroeder, Jason W

    2007-01-01

    Contrast material enhancement for cross-sectional imaging has been used since the mid 1970s for computed tomography and the mid 1980s for magnetic resonance imaging. Knowledge of the patterns and mechanisms of contrast enhancement facilitate radiologic differential diagnosis. Brain and spinal cord enhancement is related to both intravascular and extravascular contrast material. Extraaxial enhancing lesions include primary neoplasms (meningioma), granulomatous disease (sarcoid), and metastases (which often manifest as mass lesions). Linear pachymeningeal (dura-arachnoid) enhancement occurs after surgery and with spontaneous intracranial hypotension. Leptomeningeal (pia-arachnoid) enhancement is present in meningitis and meningoencephalitis. Superficial gyral enhancement is seen after reperfusion in cerebral ischemia, during the healing phase of cerebral infarction, and with encephalitis. Nodular subcortical lesions are typical for hematogenous dissemination and may be neoplastic (metastases) or infectious (septic emboli). Deeper lesions may form rings or affect the ventricular margins. Ring enhancement that is smooth and thin is typical of an organizing abscess, whereas thick irregular rings suggest a necrotic neoplasm. Some low-grade neoplasms are "fluid-secreting," and they may form heterogeneously enhancing lesions with an incomplete ring sign as well as the classic "cyst-with-nodule" morphology. Demyelinating lesions, including both classic multiple sclerosis and tumefactive demyelination, may also create an open ring or incomplete ring sign. Thick and irregular periventricular enhancement is typical for primary central nervous system lymphoma. Thin enhancement of the ventricular margin occurs with infectious ependymitis. Understanding the classic patterns of lesion enhancement--and the radiologic-pathologic mechanisms that produce them--can improve image assessment and differential diagnosis.

  8. Postoperative lumbar MR imaging with contrast enhancement. Comparison between symptomatic and asymptomatic patients

    International Nuclear Information System (INIS)

    Grane, P.; Tullberg, T.; Rydberg, J.; Lindgren, L.

    1995-01-01

    Contrast-enhanced MR imaging of the spine after surgery for lumbar disk herniation almost always shows pathologic changes. To investigate to what extent these changes are correlated to patients' actual clinical symptoms, we compared the postoperative MR findings in 19 asymptomatic patients with 42 symptomatic patients (43 levels). The asymptomatic patients underwent MR examination one year after surgery. Twenty-six of the symptomatic patients underwent MR one year of less after surgery, and in 16 patients (17 levels) MR was performed more than one year after surgery. Sixteen percent of the asymptomatic and 42% of the symptomatic patients had disk herniation at the level of previous surgery. Most of the herniated disks were found in the symptomatic patients less than one year after surgery. The amount of epidural scar tissue, displacement and thickening of nerve roots, and compression of the dural sac were also studied. Disk herniation as a probable cause of recurrent sciatica was a common finding among symptomatic patients examined one year or less after surgery. In comparing asymptomatic patients and symptomatic patients with more than one year between surgery and MR examination, no significant radiologic differences, including disk herniation, were found. (orig.)

  9. Postoperative lumbar MR imaging with contrast enhancement. Comparison between symptomatic and asymptomatic patients

    Energy Technology Data Exchange (ETDEWEB)

    Grane, P. [Dept. of Neuroradiology, Karolinska Hospital, Stockholm (Sweden); Tullberg, T. [Dept. of Orthopaedics, St. Goeran`s Hospital, Stockholm (Sweden); Rydberg, J. [Dept. of Radiology, St. Goeran`s Hospital, Stockholm (Sweden); Lindgren, L. [Dept. of Neurosurgery, Karolinska Hospital, Stockholm (Sweden)

    1995-05-01

    Contrast-enhanced MR imaging of the spine after surgery for lumbar disk herniation almost always shows pathologic changes. To investigate to what extent these changes are correlated to patients` actual clinical symptoms, we compared the postoperative MR findings in 19 asymptomatic patients with 42 symptomatic patients (43 levels). The asymptomatic patients underwent MR examination one year after surgery. Twenty-six of the symptomatic patients underwent MR one year of less after surgery, and in 16 patients (17 levels) MR was performed more than one year after surgery. Sixteen percent of the asymptomatic and 42% of the symptomatic patients had disk herniation at the level of previous surgery. Most of the herniated disks were found in the symptomatic patients less than one year after surgery. The amount of epidural scar tissue, displacement and thickening of nerve roots, and compression of the dural sac were also studied. Disk herniation as a probable cause of recurrent sciatica was a common finding among symptomatic patients examined one year or less after surgery. In comparing asymptomatic patients and symptomatic patients with more than one year between surgery and MR examination, no significant radiologic differences, including disk herniation, were found. (orig.).

  10. Ultrasonography and contrast-enhanced CT findings of tularemia in the neck.

    Science.gov (United States)

    Doğan, Serap; Ekinci, Afra; Demiraslan, Hayati; Ulu Kılıç, Ayşegül; Mavili, Ertuğrul; Öztürk, Mustafa; İmamoğlu, Hakan; Doğanay, Mehmet

    2016-01-01

    We aimed to evaluate the ultrasonography (US) and contrast-enhanced computed tomography (CECT) findings of tularemia in the neck. US and CECT findings of 58 patients with serologically proven tularemia were retrospectively evaluated. Forty-eight patients underwent US and 42 patients underwent CECT. Lymph node characteristics and parotid preauricular region involvement were analyzed using US and CECT. In addition, involvement of larynx, oropharynx, and retropharynx; presence of periorbital edema; and neck abscess formation were evaluated using CECT. Fine needle aspiration cytology (FNAC) results of enlarged lymph nodes were analyzed in 29 patients. Hypoechoic pattern, round shape, absence of hilum, and cystic necrosis were seen in most of the lymph nodes especially at level 2 and 3 on US and CECT. Matting was more commonly observed than irregular nodal border on US and CECT. Parotid preauricular region involvement was seen in 20.8% of patients on US. Oropharyngeal, retropharyngeal, laryngeal and parotid preauricular region involvement and periorbital edema were seen in 52.4%, 19.1%, 4.8%, 31%, and 9.5% of tularemia patients, respectively. Neck abscess was found in 59.5% of patients on CECT. Suppurative inflammation was the most common finding of FNAC. Tularemia should be considered in the presence of level 2 and 3 lymph nodes with cystic necrosis, matting, absence of calcification, oropharyngeal and retropharyngeal region involvement, and neck abscess, particularly in endemic areas.

  11. Contrast enhanced ultrasound of sentinel lymph nodes

    Directory of Open Access Journals (Sweden)

    XinWu Cui

    2013-03-01

    Full Text Available Sentinel lymph nodes are the first lymph nodes in the region that receive lymphatic drainage from a primary tumor. The detection or exclusion of sentinel lymph node micrometastases is critical in the staging of cancer, especially breast cancer and melanoma because it directly affects patient’s prognosis and surgical management. Currently, intraoperative sentinel lymph node biopsies using blue dye and radioisotopes are the method of choice for the detection of sentinel lymph node with high identification rate. In contrast, conventional ultrasound is not capable of detecting sentinel lymph nodes in most cases. Contrast enhanced ultrasound with contrast specific imaging modes has been used for the evaluation and diagnostic work-up of peripherally located suspected lymphadenopathy. The method allows for real-time analysis of all vascular phases and the visualization of intranodal focal “avascular” areas that represent necrosis or deposits of neoplastic cells. In recent years, a number of animal and human studies showed that contrast enhanced ultrasound can be also used for the detection of sentinel lymph node, and may become a potential application in clinical routine. Several contrast agents have been used in those studies, including albumin solution, hydroxyethylated starch, SonoVue®, Sonazoid® and Definity®. This review summarizes the current knowledge about the use of ultrasound techniques in detection and evaluation of sentinel lymph node.

  12. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min

    1995-01-01

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease

  13. Avascular necrosis of femoral head: findings of contrast-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Yong Moon; Kang, Heung Sik; Kim, Chu Wan; Kim, Hee Joong; Kim, Young Min [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1995-06-15

    To evaluate the findings and the role of contrast enhanced magnetic resonance imaging in avascular necrosis of femoral head. Sixteen patients with avascular necorsis of femoral head were examined with MRI. T1-weighted and T2-weighted image and contrast-enhanced T1-weighted images were obtained. Enhancing characteristics of the necrotic area and synovium were determined. Also a change of the disease extent after enhancement was assessed. Twenty seven avascular necrosis of the femoral head including 11 cases of bilateral lesion were detected. Fifteen cases revealed collapse of the femoral head. The portions of the lesion with low signal intensity on T1-weighted images and high signal intensity on T2-weighted images showed contrast enhancement in 15 cases. However, the potions with low signal intensities both on T1 and T2-weighted images showed enhancement in one case. There was no significant change of the disease extent after enhancement. Synovium showed enhancement in 18 cases, and joint effusion was detected in 23 cases. Contrast enhanced MR images may be helpful in predicting histopathologic findings of avascular necrosis of the femoral head, but not useful for evaluating the extent of disease.

  14. Contrast-enhanced NMR imaging: animal studies using gadolinium-DTPA complex

    International Nuclear Information System (INIS)

    Brasch, R.C.; Weinmann, H.J.; Wesbey, G.E.

    1984-01-01

    Gadolinium (Gd)-DTPA complex was assessed as a nuclear magnetic resonance (NMR) contrast-enhancing agent by experimentally imaging normal and diseased animals. After intravenous injection, Gd-DTPA, a strongly paramagnetic complex by virtue of unpaired electrons, was rapidly excreted into the urine of rats, producing an easily observable contrast enhancement on NMR images in kidney parenchyma and urine. Sterile soft-tissue abscesses demonstrated an obvious rim pattern of enhancement. A focus of radiation-induced brain damage in a canine model was only faintly detectable on spin-echo NMR images before contrast administration; after 0.5 mmol/kg Gd-DTPA administration, the lesion intensity increased from 3867 to 5590. In comparison, the normal brain with an intact blood-brain barrier remained unchanged in NMR characterization. Gd-DTPA is a promising new NMR contrast enhancer for the clinical assessment of renal function, of inflammatory lesions, and of focal disruption of the blood-brain barrier

  15. Enhanced renal image contrast by ethanol fixation in phase-contrast X-ray computed tomography.

    Science.gov (United States)

    Shirai, Ryota; Kunii, Takuya; Yoneyama, Akio; Ooizumi, Takahito; Maruyama, Hiroko; Lwin, Thet Thet; Hyodo, Kazuyuki; Takeda, Tohoru

    2014-07-01

    Phase-contrast X-ray imaging using a crystal X-ray interferometer can depict the fine structures of biological objects without the use of a contrast agent. To obtain higher image contrast, fixation techniques have been examined with 100% ethanol and the commonly used 10% formalin, since ethanol causes increased density differences against background due to its physical properties and greater dehydration of soft tissue. Histological comparison was also performed. A phase-contrast X-ray system was used, fitted with a two-crystal X-ray interferometer at 35 keV X-ray energy. Fine structures, including cortex, tubules in the medulla, and the vessels of ethanol-fixed kidney could be visualized more clearly than that of formalin-fixed tissues. In the optical microscopic images, shrinkage of soft tissue and decreased luminal space were observed in ethanol-fixed kidney; and this change was significantly shown in the cortex and outer stripe of the outer medulla. The ethanol fixation technique enhances image contrast by approximately 2.7-3.2 times in the cortex and the outer stripe of the outer medulla; the effect of shrinkage and the physical effect of ethanol cause an increment of approximately 78% and 22%, respectively. Thus, the ethanol-fixation technique enables the image contrast to be enhanced in phase-contrast X-ray imaging.

  16. Focal hepatic lesions: contrast-enhancement patterns at pulse-inversion harmonic US using a microbubble contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun-A; Yoon, Kwon-Ha; Lee, Young-Hwan; Kim, Hye-Won; Juhng, Seon-Kwan; Won, Jong-Jin [Wonkwang University, Iksan (Korea, Republic of)

    2003-12-15

    To analyze the contrast-enhancement patterns obtained at pulse-inversion harmonic imaging (PIHI) of focal hepatic lesions, and to thus determine tumor vascularity and the acoustic emission effect. We reviewed pulse-inversion images in 90 consecutive patients with focal hepatic lesions, namely hepatocellular carcinoma (HHC) (n=43), metastases (n=30), and hemangioma (n=17). Vascular and delayed phase images were obtained immediately and five minutes following the injection of a microbubble contrast agent. Tumoral vascularity at vascular phase imaging and the acoustic emission effect at delayed phase imaging were each classified as one of four patterns. Vascular phase images depicted internal vessels in 93% of HCCs, marginal vessels in 83% of metastases, and peripheral enhancement in 71% of hemangiomas. Delayed phase images showed inhomogeneous enhancement in 86% of HCCs; hypoechoic, decreased enhancement in 93% of metastases; and hypoechoic and reversed echogenicity in 65% of hemangiomas. Vascular and delayed phase enhancement patterns were associated with a specificity of 91% or greater, and 92% or greater, respectively, and with positive predictive values of 71% or greater, and 85% or greater, respectively. Contrast-enhancement patterns depicting tumoral vascularity and the acoustic emission effect at PIHI can help differentiate focal hepatic lesions.

  17. Clinical validation of semi-automated software for volumetric and dynamic contrast enhancement analysis of soft tissue venous malformations on magnetic resonance imaging examination

    Energy Technology Data Exchange (ETDEWEB)

    Caty, Veronique [Hopital Maisonneuve-Rosemont, Universite de Montreal, Department of Radiology, Montreal, QC (Canada); Kauffmann, Claude; Giroux, Marie-France; Oliva, Vincent; Therasse, Eric [Centre Hospitalier de l' Universite de Montreal (CHUM), Universite de Montreal and Research Centre, CHUM (CRCHUM), Department of Radiology, Montreal, QC (Canada); Dubois, Josee [Centre Hospitalier Universitaire Sainte-Justine et Universite de Montreal, Department of Radiology, Montreal, QC (Canada); Mansour, Asmaa [Institut de Cardiologie de Montreal, Heart Institute Coordinating Centre, Montreal, QC (Canada); Piche, Nicolas [Object Research System, Montreal, QC (Canada); Soulez, Gilles [Centre Hospitalier de l' Universite de Montreal (CHUM), Universite de Montreal and Research Centre, CHUM (CRCHUM), Department of Radiology, Montreal, QC (Canada); CHUM - Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada)

    2014-02-15

    To evaluate venous malformation (VM) volume and contrast-enhancement analysis on magnetic resonance imaging (MRI) compared with diameter evaluation. Baseline MRI was undertaken in 44 patients, 20 of whom were followed by MRI after sclerotherapy. All patients underwent short-tau inversion recovery (STIR) acquisitions and dynamic contrast assessment. VM diameters in three orthogonal directions were measured to obtain the largest and mean diameters. Volumetric reconstruction of VM was generated from two orthogonal STIR sequences and fused with acquisitions after contrast medium injection. Reproducibility (interclass correlation coefficients [ICCs]) of diameter and volume measurements was estimated. VM size variations in diameter and volume after sclerotherapy and contrast enhancement before sclerotherapy were compared in patients with clinical success or failure. Inter-observer ICCs were similar for diameter and volume measurements at baseline and follow-up (range 0.87-0.99). Higher percentages of size reduction after sclerotherapy were observed with volume (32.6 ± 30.7 %) than with diameter measurements (14.4 ± 21.4 %; P = 0.037). Contrast enhancement values were estimated at 65.3 ± 27.5 % and 84 ± 13 % in patients with clinical failure and success respectively (P = 0.056). Venous malformation volume was as reproducible as diameter measurement and more sensitive in detecting therapeutic responses. Patients with better clinical outcome tend to have stronger malformation enhancement. (orig.)

  18. Contrast-enhanced dynamic MR imaging of parasellar tumor using fast spin-echo sequence

    International Nuclear Information System (INIS)

    Kusunoki, Katsusuke; Ohue, Shiro; Ichikawa, Haruhisa; Saito, Masahiro; Sadamoto, Kazuhiko; Sakaki, Saburo; Miki, Hitoshi.

    1995-01-01

    We have applied a new dynamic MRI technique that uses a fast spin-echo sequence to parasellar tumors. This sequence has less susceptible effect and better spatial resolution than a gradient echo sequence, providing faster images than a short spin-echo sequence does. Image was obtained in the coronal or sagittal plane using a 1.5T clinical MRI system, and then, dynamic MR images were acquired every 10 to 20 sec after administration of Gd-DTPA (0.1 mmol/kg). The subjects were 12 patients (5 microadenomas, 5 macroadenomas and 2 Rathke's cleft cysts) and 5 normal volunteers. As for volunteers, the cavernous sinus, pituitary stalk and posterior pituitary gland were contrasted on the first image, followed by visualization of the proximal portion adjacent to the junction of the infundibulum and the anterior pituitary gland, and finally by contrasting the distal portion of the anterior pituitary gland. There was a difference with respect to tumor contrast between microadenomas and macroadenomas. In the case of the macroadenomas, the tumor was contrasted at the same time as, or faster than the anterior pituitary gland, while with the microadenomas the tumor was enhanced later than the anterior pituitary gland. No enhancement with contrast medium was seen in Rathke's cleft cysts. In addition, it was possible to differentiate a recurrent tumor from a piece of muscle placed at surgery since the images obtained by the fast spin-echo sequence were clearer than those obtained by gradient echo sequence. (author)

  19. The analysis of the contrast enhanced lesions on cerebro-vascular diseases

    International Nuclear Information System (INIS)

    Terada, Tomoaki; Nishiguchi, Takashi; Hyoutani, Genhachi; Miyamoto, Kazuki; Komai, Norihiko

    1989-01-01

    The contrast enhancement of cerebro-vascular diseases on CT is thought to be due to the increase of the cerebral blood volume (CBV) and/or the disruption of the blood brain barrier (BBB). However, it is difficult to differentiate these two conditions only by contrast enhanced CT. We employed dynamic CT (DCT) to analyse these lesions with respect to the patterns of time-density curve and peak height (PH) of the curve upon the theoretical basis that flattening of the latter part of the time-density curve reflected the degree of BBB disruption and PH reflected the CBV. In all cases of hypertensive intracerebral hemorrhage (11 cases), the contrast enhanced lesion around the hematoma showed marked BBB disruption according to the results of DCT. In 11 cases of cerebral infarction, patterns of BBB disruption and CBV varied at the contrast enhanced lesions according to the result of DCT. However, all contrast enhanced lesions with increased PH were associated with hemorrhagic infarction. Thus, the precise analysis of DCT provides appropriate therapeutic schedules by predicting the occurrence of hemorrhagic infarction. (author)

  20. Contrast-enhanced power Doppler ultrasonography of the metacarpophalangeal joints in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, Michel; Strandberg, Charlotte

    2003-01-01

    The aim of this study was to examine, with dynamic contrast-enhanced MRI as the reference, if contrast-enhanced power Doppler ultrasonography (CE PDUS) of rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints provides additional information for evaluation of synovial inflammation compared...... with PDUS. One MCP joint in each of 15 RA patients and 3 healthy control persons were examined with PDUS before and after intravenous bolus Levovist contrast injection. Corresponding rates of early synovial enhancement (RESE), previously shown to be closely related to histopathological synovitis, were...... calculated from dynamic contrast-enhanced MR images obtained the same day. Prior to ultrasonography, the joint was evaluated clinically. Levovist increased the flow signal in 7 of 9 joints with pre-contrast flow-signal and in 0 of 9 without pre-contrast signal. No healthy controls showed CE PDUS signal...

  1. Contrast-enhanced ultrasonography depicts small tumor vessels for the evaluation of pancreatic tumors

    International Nuclear Information System (INIS)

    Okamoto, Yuko; Kawamoto, Hirofumi; Takaki, Akinobu; Ishida, Etsuji; Ogawa, Tsuneyoshi; Kuwaki, Kenji; Kobayashi, Yoshiyuki; Sakaguchi, Kohsaku; Shiratori, Yasushi

    2007-01-01

    Objective: The aim of this study is to evaluate the efficacy of contrast-enhanced ultrasonography for the diagnosis of pancreatic tumors. Materials and methods: Contrast-enhanced ultrasonography with Levovist was performed on 62 consecutive patients (53 with pancreatic cancer, 4 with islet cell tumor, 3 with inflammatory pancreatic tumor, and 2 with metastatic tumor). The vascular and perfusion image phases of the tumors were evaluated and compared with the findings of contrast-enhanced computed tomography. Results: Contrast-enhanced ultrasonography showed tumor vessels around and/or in the tumor at the vascular image phase in 79% of pancreatic cancer patients (42/53). At the perfusion image phase, 96% of pancreatic cancers (51/53) were classified as hypo-enhancement type. However, tiny spotty or irregular heterogeneous enhanced lesions were found in 84% of hypo-enhanced pancreatic cancer patients (43/51). The presence of small vessels at the vascular image phase was closely correlated with the presence of these intratumor regional enhanced lesions at the perfusion image phase (κ coefficient = 0.42). The sensitivity of contrast-enhanced ultrasonography (100%) for pancreatic cancer was superior to that of contrast-enhanced computed tomography (91%), but no significant difference was observed between the two (McNemar test: p = 0.063). Conclusion: Contrast-enhanced ultrasonography with Levovist successfully visualizes fine vessels and enhancement in pancreatic tumors, and is useful for evaluating pancreatic tumors

  2. Gray-scale contrast-enhanced utrasonography in detecting sentinel lymph nodes: An animal study

    International Nuclear Information System (INIS)

    Wang Yuexiang; Cheng Zhigang; Li Junlai; Tang Jie

    2010-01-01

    Objective: To investigate the usefulness of gray-scale contrast-enhanced ultrasonography for detecting sentinel lymph nodes. Methods: Contrast-enhanced ultrasonography was performed in five normal dogs (four female and one male) after subcutaneous administration of a sonographic contrast agent (Sonovue, Bracco, Milan, Italy). Four distinct regions in each animal were examined. After contrast-enhanced ultrasonography, 0.8 ml of blue dye was injected into the same location as Sonovue and the sentinel lymph nodes were detected by surgical dissection. The findings of contrast-enhanced ultrasonography were compared with those of the blue dye. Results: Twenty-one sentinel lymph nodes were detected by contrast-enhanced ultrasonography while 23 were identified by blue dye with surgical dissection. Compared with the blue dye, the detection rate of enhanced ultrasonography for the sentinel lymph nodes is 91.3% (21/23). Two patterns of enhancement in the sentinel lymph nodes were observed: complete enhancement (5 sentinel lymph nodes) and partial enhancement (16 sentinel lymph nodes). The lymphatic channels were demonstrated as hyperechoic linear structures leading from the injection site and could be readily followed to their sentinel lymph nodes. Histopathologic examination showed proliferation of lymphatic follicles or lymphatic sinus in partial enhanced sentinel lymph nodes while normal lymphatic tissue was demonstrated in completely enhanced sentinel lymph nodes. Conclusions: Sonovue combined with gray-scale contrast-enhanced ultrasonography may provide a feasible method for detecting sentinel lymph nodes.

  3. International guidelines for contrast-enhanced ultrasonography

    DEFF Research Database (Denmark)

    Nolsøe, Christian Pállson; Lorentzen, Torben

    2016-01-01

    The intent of this review is to discuss and comment on common clinical scenarios in which contrast-enhanced ultrasonography (CEUS) may play a decisive role and to illustrate important points with typical cases. With the advent of CEUS, the scope of indications for ultrasonography has been dramati...

  4. Exogenous attention enhances 2nd-order contrast sensitivity

    Science.gov (United States)

    Barbot, Antoine; Landy, Michael S.; Carrasco, Marisa

    2011-01-01

    Natural scenes contain a rich variety of contours that the visual system extracts to segregrate the retinal image into perceptually coherent regions. Covert spatial attention helps extract contours by enhancing contrast sensitivity for 1st-order, luminance-defined patterns at attended locations, while reducing sensitivity at unattended locations, relative to neutral attention allocation. However, humans are also sensitive to 2nd-order patterns such as spatial variations of texture, which are predominant in natural scenes and cannot be detected by linear mechanisms. We assess whether and how exogenous attention—the involuntary and transient capture of spatial attention—affects the contrast sensitivity of channels sensitive to 2nd-order, texture-defined patterns. Using 2nd-order, texture-defined stimuli, we demonstrate that exogenous attention increases 2nd-order contrast sensitivity at the attended location, while decreasing it at unattended locations, relative to a neutral condition. By manipulating both 1st- and 2nd-order spatial frequency, we find that the effects of attention depend both on 2nd-order spatial frequency of the stimulus and the observer’s 2nd-order spatial resolution at the target location. At parafoveal locations, attention enhances 2nd-order contrast sensitivity to high, but not to low 2nd-order spatial frequencies; at peripheral locations attention also enhances sensitivity to low 2nd-order spatial frequencies. Control experiments rule out the possibility that these effects might be due to an increase in contrast sensitivity at the 1st-order stage of visual processing. Thus, exogenous attention affects 2nd-order contrast sensitivity at both attended and unattended locations. PMID:21356228

  5. Contrast-enhanced CMR in patients after percutaneous closure of the left atrial appendage: A pilot study

    Directory of Open Access Journals (Sweden)

    Petersen Steffen E

    2011-07-01

    Full Text Available Abstract Background To evaluate the feasibility and value of first-pass contrast-enhanced dynamic and post-contrast 3D CMR in patients after transcatheter occlusion of left atrial appendage (LAA to identify incorrect placement and persistent leaks. Methods 7 patients with different occluder systems (n = 4 PLAATO; n = 2 Watchman; n = 1 ACP underwent 2 contrast-enhanced (Gd-DOTA CMR sequences (2D TrueFISP first-pass perfusion and 3D-TurboFLASH to assess localization, artifact size and potential leaks of the devices. Perfusion CMR was analyzed visually and semi-quantitatively to identify potential leaks. Results All occluders were positioned within the LAA. The ACP occluder presented the most extensive artifact size. Visual assessment revealed a residual perfusion of the LAA apex in 4 cases using first-pass perfusion and 3D-TurboFLASH indicating a suboptimal LAA occlusion. By assessing signal-to-time-curves the cases with a visually detected leak showed a 9-fold higher signal-peak in the LAA apex (567 ± 120% increase from baseline signal than those without a leak (61 ± 22%; p Conclusion This CMR pilot study provides valuable non-invasive information in patients after transcatheter occlusion of the LAA to identify correct placement and potential leaks. We recommend incorporating CMR in future clinical studies to evaluate new device types.

  6. Appropriate Contrast Enhancement Measures for Brain and Breast Cancer Images

    Directory of Open Access Journals (Sweden)

    Suneet Gupta

    2016-01-01

    Full Text Available Medical imaging systems often produce images that require enhancement, such as improving the image contrast as they are poor in contrast. Therefore, they must be enhanced before they are examined by medical professionals. This is necessary for proper diagnosis and subsequent treatment. We do have various enhancement algorithms which enhance the medical images to different extents. We also have various quantitative metrics or measures which evaluate the quality of an image. This paper suggests the most appropriate measures for two of the medical images, namely, brain cancer images and breast cancer images.

  7. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    International Nuclear Information System (INIS)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun; Kim, Tae Kyoung; Khalili, Korosh; Bae, Mi Hyun; Lee, Joo Yeon; Lee, Sung-Gyu; Yu, Eun Sil

    2010-01-01

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ( pre L-S) and contrast-enhanced ( post L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ( post L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for pre L-S, post L-S and post L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of pre L-S and post L-S did not differ (P ≥ 0.054), despite a trend towards a lower accuracy with post L-S. post L-B yielded higher accuracy than pre L-S at threshold levels of 5% and 10% (P ≤ 0.002) and similar accuracy to pre L-S at the other threshold levels (P ≥ 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  8. Is hepatotropic contrast enhanced MR a more effective method in differential diagnosis of hemangioma than multi-phase CT and unenhanced MR?

    Directory of Open Access Journals (Sweden)

    Markiet Karolina

    2011-04-01

    Full Text Available Abstract Background Cavernous hemangiomas are the most frequent neoplasms of the liver and in routine clinical practice they often need to be differentiated from malignant tumors and other benign focal lesions. The purpose of this study is to evaluate whether diagnostic accuracy of magnetic resonance imaging (MRI of hepatic hemangiomas, showing atypical pattern on US, improves with the use of Gd-BOPTA in comparison with contrast-enhanced multi-phase computed tomography (CT. Methods 178 consecutive patients with ambiguous hepatic masses showing atypical hyperechoic pattern on grey-scale US, underwent unenhanced and contrast-enhanced multi-phase multi-detector CT and MR (1.5T with the use of liver-specific contrast medium gadobenate dimeglumine (Gd-BOPTA. After intravenous contrast administration arterial (HAP, venous-portal (PVP, equilibrium phases (EP both in CT and MR and additionally hepatobiliary phase (HBP in MR were obtained. 398 lesions have been detected including 99 hemangiomas and 299 other lesions. Results In non-enhanced MDCT examination detection of hemangiomas was characterized by sensitivity of 76%, specificity of 90%, PPV of 71%, NPV of 92% and accuracy of 86%. Non-enhanced MR examination showed sensitivity of 98%, specificity of 99%, PPV of 99%, NPV of 99% and accuracy of 99%. After intravenous administration of contrast medium in MR the mentioned above parameters did not increase significantly. Conclusion Gd-BOPTA-enhanced MR in comparison with unenhanced MRI does not improve diagnostic accuracy in discriminating hemangiomas that show non-specific appearance in ultrasound examination. Unenhanced MR as a method of choice should directly follow US in course of diagnostic algorithm in differentiation of hemangiomas from other liver tumors.

  9. Assessment of irradiated brain metastases using dynamic contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Almeida-Freitas, Daniela B.; Pinho, Marco C.; Otaduy, Maria C.G.; Costa Leite, Claudia da; Braga, Henrique F.; Meira-Freitas, Daniel

    2014-01-01

    The purpose of this study was to evaluate the effect of stereotactic radiosurgery (SRS) on cerebral metastases using the transfer constant (K trans ) assessed by dynamic contrast-enhanced (DCE) MRI. Furthermore, we aimed to evaluate the ability of K trans measurements to predict midterm tumor outcomes after SRS. The study received institutional review board approval, and informed consent was obtained from all subjects. Twenty-six adult patients with a total of 34 cerebral metastases underwent T1-weighted DCE MRI in a 1.5-T magnet at baseline (prior to SRS) and 4-8 weeks after treatment. Quantitative analysis of DCE MRI was performed by generating K trans parametric maps, and region-of-interest-based measurements were acquired for each metastasis. Conventional MRI was performed at least 16 weeks after SRS to assess midterm tumor outcome using volume variation. The mean (±SD) K trans value was 0.13 ± 0.11 min -1 at baseline and 0.08 ± 0.07 min -1 after 4-8 weeks post-treatment (p trans after SRS was predictive of tumor progression (hazard ratio = 1.50; 95 % CI = 1.16-1.70, p trans showed a sensitivity of 78 % and a specificity of 85 % for the prediction of progression at midterm follow-up. SRS was associated with a reduction of K trans values of the cerebral metastases in the early post-treatment period. Furthermore, K trans variation as assessed using DCE MRI may be helpful to predict midterm outcomes after SRS. (orig.)

  10. Nanodiamond-Manganese dual mode MRI contrast agents for enhanced liver tumor detection.

    Science.gov (United States)

    Hou, Weixin; Toh, Tan Boon; Abdullah, Lissa Nurrul; Yvonne, Tay Wei Zheng; Lee, Kuan J; Guenther, Ilonka; Chow, Edward Kai-Hua

    2017-04-01

    Contrast agent-enhanced magnetic resonance (MR) imaging is critical for the diagnosis and monitoring of a number of diseases, including cancer. Certain clinical applications, including the detection of liver tumors, rely on both T1 and T2-weighted images even though contrast agent-enhanced MR imaging is not always reliable. Thus, there is a need for improved dual mode contrast agents with enhanced sensitivity. We report the development of a nanodiamond-manganese dual mode contrast agent that enhanced both T1 and T2-weighted MR imaging. Conjugation of manganese to nanodiamonds resulted in improved longitudinal and transverse relaxivity efficacy over unmodified MnCl 2 as well as clinical contrast agents. Following intravenous administration, nanodiamond-manganese complexes outperformed current clinical contrast agents in an orthotopic liver cancer mouse model while also reducing blood serum concentration of toxic free Mn 2+ ions. Thus, nanodiamond-manganese complexes may serve as more effective dual mode MRI contrast agent, particularly in cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Novel Gd nanoparticles enhance vascular contrast for high-resolution magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Tot Bui

    2010-09-01

    Full Text Available Gadolinium (Gd, with its 7 unpaired electrons in 4f orbitals that provide a very large magnetic moment, is proven to be among the best agents for contrast enhanced MRI. Unfortunately, the most potent MR contrast agent based on Gd requires relatively high doses of Gd. The Gd-chelated to diethylene-triamine-penta-acetic acid (DTPA, or other derivatives (at 0.1 mmole/kg recommended dose, distribute broadly into tissues and clear through the kidney. These contrast agents carry the risk of Nephrogenic Systemic Fibrosis (NSF, particularly in kidney impaired subjects. Thus, Gd contrast agents that produce higher resolution images using a much lower Gd dose could address both imaging sensitivity and Gd safety.To determine whether a biocompatible lipid nanoparticle with surface bound Gd can improve MRI contrast sensitivity, we constructed Gd-lipid nanoparticles (Gd-LNP containing lipid bound DTPA and Gd. The Gd-LNP were intravenously administered to rats and MR images collected. We found that Gd in Gd-LNP produced a greater than 33-fold higher longitudinal (T(1 relaxivity, r(1, constant than the current FDA approved Gd-chelated contrast agents. Intravenous administration of these Gd-LNP at only 3% of the recommended clinical Gd dose produced MRI signal-to-noise ratios of greater than 300 in all vasculatures. Unlike current Gd contrast agents, these Gd-LNP stably retained Gd in normal vasculature, and are eliminated predominately through the biliary, instead of the renal system. Gd-LNP did not appear to accumulate in the liver or kidney, and was eliminated completely within 24 hrs.The novel Gd-nanoparticles provide high quality contrast enhanced vascular MRI at 97% reduced dose of Gd and do not rely on renal clearance. This new agent is likely to be suitable for patients exhibiting varying degrees of renal impairment. The simple and adaptive nanoparticle design could accommodate ligand or receptor coating for drug delivery optimization and in vivo drug

  12. Interobserver Variation of the Bolus-and-Burst Method for Pancreatic Perfusion with Dynamic – Contrast-Enhanced Ultrasound

    Czech Academy of Sciences Publication Activity Database

    Stangeland, M.; Engjom, T.; Mézl, M.; Jiřík, Radovan; Gilja, O.H.; Dimcevski, G.; Nylund, K.

    2017-01-01

    Roč. 3, č. 3 (2017), E99-E106 E-ISSN 2199-7152 Institutional support: RVO:68081731 Keywords : interobserver * dynamic contrast-enhanced ultrasound * perfusion * pancreas Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Medical engineering https://www.thieme-connect.com/products/ejournals/abstract/10.1055/s-0043-110475

  13. A developed unsharp masking method for images contrast enhancement

    International Nuclear Information System (INIS)

    Zaafouri, A.; Sayadi, M.; Fnaiech, F.

    2011-01-01

    In this paper, we propose a developed unsharp masking process for contrast image enhancement. The main idea here is to enhance the dark and bright area in the same way which matches the response of human visual system well. Then in order to reduce the noise effect, a mean weighted high pass filter is used for edge extraction. The proposed method gives satisfactory results for wide range of low contrast images compared with others known approaches.

  14. Microwave ablation of liver metastases guided by contrast-enhanced ultrasound

    DEFF Research Database (Denmark)

    Lorentzen, T; Skjoldbye, B O; Nolsoe, C P

    2011-01-01

    The aim of our study was to evaluate the efficacy of microwave (MW) ablation of liver metastases guided by B-mode ultrasound (US) and contrast-enhanced US (CEUS).......The aim of our study was to evaluate the efficacy of microwave (MW) ablation of liver metastases guided by B-mode ultrasound (US) and contrast-enhanced US (CEUS)....

  15. Diagnositc value of 3D-gradient echo dynamic contrast enhanced MRI in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ik; Chung, Soo Young; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Shim, Jeong Won [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    To assess the usefulness of 3D-gradient echo dynamic contrast enhanced MRI (3D-DMRI) in the diagnosis of breast cancer and to determine the most useful parameter for this diagnosis. Using a 1.0T MR unit, (Magnetom, Siemens, Erlaugen, Germany), 3D-DMRI (TR/TE=3D30/12) with Gd-DTPA was performed in 38 cases of breast cancer, 22 of fibroadenoma, and in three normal volunteers. We retrospectively evaluated the findings according to the speed on dynamic study and maximal amount of contrast enhancement during the delayed phase;we calculated the contrast index and morphology of the cancers and compared diagnostic accuracy among these three diagnostic parameters. On conventional spin-echo T1-and T2-weighted images, there was no significant difference of signal intensity between benign fibroadenoma and breast carcinoma. Rapid contrast enhancement (within one minute) was noted in 35 breast cancer lesions (92.1%), but relatively low and slow contrast enhancement (after five minutes) was noted in three such lesions (7.9%). Gradual contrast enhancement was noted in 21 lesions of fibroadenoma(95.5%), but a moderate degree of rapid contrast enhancement (from three to five minutes) was noted in the other case (7.9%). of On the delayed enhanced phase of 3D-DMRI, the maximal amount of contrast enhancement showed no significant difference between fibroadenoma and cancer. On 3D-DMRI, an irregular, spiculated border, with high contrast enhancement was noted in all cases of breast cancer, in particular, irregular thick peripheral contrast enhancement with central necrosis was noted 11cases(28.9%). For the diagnosis of breast cancer, 3D-DMRI is a useful technique. Among the diagnostic criteria of speed, maximal amount of contrast enhancement and morphology, morphologic change after contrast enhancement study was the most useful diagnostic parameter.=20.

  16. Diagnositc value of 3D-gradient echo dynamic contrast enhanced MRI in breast cancer

    International Nuclear Information System (INIS)

    Yang, Ik; Chung, Soo Young; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Shim, Jeong Won

    1997-01-01

    To assess the usefulness of 3D-gradient echo dynamic contrast enhanced MRI (3D-DMRI) in the diagnosis of breast cancer and to determine the most useful parameter for this diagnosis. Using a 1.0T MR unit, (Magnetom, Siemens, Erlaugen, Germany), 3D-DMRI (TR/TE=3D30/12) with Gd-DTPA was performed in 38 cases of breast cancer, 22 of fibroadenoma, and in three normal volunteers. We retrospectively evaluated the findings according to the speed on dynamic study and maximal amount of contrast enhancement during the delayed phase;we calculated the contrast index and morphology of the cancers and compared diagnostic accuracy among these three diagnostic parameters. On conventional spin-echo T1-and T2-weighted images, there was no significant difference of signal intensity between benign fibroadenoma and breast carcinoma. Rapid contrast enhancement (within one minute) was noted in 35 breast cancer lesions (92.1%), but relatively low and slow contrast enhancement (after five minutes) was noted in three such lesions (7.9%). Gradual contrast enhancement was noted in 21 lesions of fibroadenoma(95.5%), but a moderate degree of rapid contrast enhancement (from three to five minutes) was noted in the other case (7.9%). of On the delayed enhanced phase of 3D-DMRI, the maximal amount of contrast enhancement showed no significant difference between fibroadenoma and cancer. On 3D-DMRI, an irregular, spiculated border, with high contrast enhancement was noted in all cases of breast cancer, in particular, irregular thick peripheral contrast enhancement with central necrosis was noted 11cases(28.9%). For the diagnosis of breast cancer, 3D-DMRI is a useful technique. Among the diagnostic criteria of speed, maximal amount of contrast enhancement and morphology, morphologic change after contrast enhancement study was the most useful diagnostic parameter.=20

  17. Attention enhances contrast appearance via increased input baseline of neural responses.

    Science.gov (United States)

    Cutrone, Elizabeth K; Heeger, David J; Carrasco, Marisa

    2014-12-30

    Covert spatial attention increases the perceived contrast of stimuli at attended locations, presumably via enhancement of visual neural responses. However, the relation between perceived contrast and the underlying neural responses has not been characterized. In this study, we systematically varied stimulus contrast, using a two-alternative, forced-choice comparison task to probe the effect of attention on appearance across the contrast range. We modeled performance in the task as a function of underlying neural contrast-response functions. Fitting this model to the observed data revealed that an increased input baseline in the neural responses accounted for the enhancement of apparent contrast with spatial attention. © 2014 ARVO.

  18. A New Risk Factor Profile for Contrast-Induced Acute Kidney Injury in Patients Who Underwent an Emergency Percutaneous Coronary Intervention.

    Science.gov (United States)

    Yuan, Ying; Qiu, Hong; Song, Lei; Hu, Xiaoying; Luo, Tong; Zhao, Xueyan; Zhang, Jun; Wu, Yuan; Qiao, Shubin; Yang, Yuejin; Gao, Runlin

    2018-07-01

    We developed a new risk factor profile for contrast-induced acute kidney injury (CI-AKI) under a new definition in patients who underwent an emergency percutaneous coronary intervention (PCI). Consecutive patients (n = 1061) who underwent an emergency PCI were divided into a derivation group (n = 761) and a validation group (n = 300). The rates of CI-AKI were 23.5% (definition 1: serum creatinine [SCr] increase ≥25% in 72 hours), 4.3% (definition 2: SCr increase ≥44.2 μmol/L in 72 hours), and 7.0% (definition 3: SCr increase ≥44.2 μmol/L in 7 days). Due to the high sensitivity of definition 1 and the high rate of missed cases for late diagnosis of CI-AKI under definition 2, definition 3 was used in the study. The risk factor profile included body surface area 15.00 × 10 9 /L ( P = .047), estimated glomerular filtration rate 133 μmol/L ( P = .007), intra-aortic balloon pump application ( P = .006), and diuretics administration ( P risk factor profile of CI-AKI under a new CI-AKI definition in emergency PCI patients is easily applicable with a useful predictive value.

  19. Pharmacokinetic parameters derived from dynamic contrast enhanced MRI of cervical cancers predict chemoradiotherapy outcome

    International Nuclear Information System (INIS)

    Andersen, Erlend K.F.; Hole, Knut Håkon; Lund, Kjersti V.; Sundfør, Kolbein; Kristensen, Gunnar B.; Lyng, Heidi; Malinen, Eirik

    2013-01-01

    Purpose: To assess the prognostic value of pharmacokinetic parameters derived from pre-chemoradiotherapy dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) of cervical cancer patients. Materials and methods: Seventy-eight patients with locally advanced cervical cancer underwent DCE-MRI with Gd-DTPA before chemoradiotherapy. The pharmacokinetic Brix and Tofts models were fitted to contrast enhancement curves in all tumor voxels, providing histograms of several pharmacokinetic parameters (Brix: A Brix , k ep , k el , Tofts: K trans , ν e ). A percentile screening approach including log-rank survival tests was undertaken to identify the clinically most relevant part of the intratumoral parameter distribution. Clinical endpoints were progression-free survival (PFS) and locoregional control (LRC). Multivariate analysis including FIGO stage and tumor volume was used to assess the prognostic significance of the imaging parameters. Results: A Brix , k el , and K trans were significantly (P e was significantly positively correlated with PFS only. k ep showed no association with any endpoint. A Brix was positively correlated with K trans and ν e , and showed the strongest association with endpoint in the log-rank testing. k el and K trans were independent prognostic factors in multivariate analysis with LRC as endpoint. Conclusions: Parameters estimated by pharmacokinetic analysis of DCE-MR images obtained prior to chemoradiotherapy may be used for identifying patients at risk of treatment failure

  20. Contrast-enhanced ultrasound features of histologically proven focal nodular hyperplasia: diagnostic performance compared with contrast-enhanced CT

    International Nuclear Information System (INIS)

    Wang, Wei; Chen, Li-Da; Liu, Guang-Jian; Xu, Zuo-Feng; Xie, Xiao-Yan; Wang, Yan; Zhou, Lu-Yao; Lu, Ming-De; Shen, Shun-Li

    2013-01-01

    To investigate and compare contrast-enhanced ultrasound (CEUS) in the characterisation of histologically proven focal nodular hyperplasia (FNH) with contrast-enhanced computed tomography (CECT). CEUS was performed in 85 patients with 85 histologically proven FNHs. Enhancement, centrifugal filling, spoke-wheel arteries, feeding artery and central scarring were reviewed and correlated with lesion size or liver background. Independent factors for predicting FNH from other focal liver lesions (FLLs) were evaluated. Forty-seven FLLs with CECT were randomly selected for comparison of diagnostic performance with CEUS. Centrifugal filling was more common (P = 0.002) and the significant predictor (P = 0.003) in FNHs ≤3 cm. Lesion size or liver background has no significant influence on the detection rate of the spoke-wheel arteries and feeding artery (P > 0.05). Central scarring was found in 42.6 % of FNHs ≥3 cm (P = 0.000). The area under the ROC curve, sensitivity and specificity showed no significant differences between CEUS and CECT (P > 0.05), except that the sensitivity of CEUS was better for reader 1 (P = 0.041). CEUS is valuable in characterising centrifugal filling signs or spoke wheels in small FNHs and should be employed as the first-line imaging technique for diagnosis of FNH. (orig.)

  1. Relationship between the natural history of chronic subdural hematoma and enhancement of the inner membrane on post-contrast CT scan

    International Nuclear Information System (INIS)

    Nakaguchi, Hiroshi; Yoshimasu, Norio; Tanishima, Takeo

    2003-01-01

    The purpose of this study was to determine the features and natural history of the inner membrane in CSDH (chronic subdural hematoma) patients using pre- and post-contrast CT scans. Twenty-four patients with CSDH (28 hematomas) who underwent pre- and post-contrast CT scanning prior to surgery ware studied. CSDH was classified according to the internal architecture as the homogeneous (HM) type, the laminar (LM) type, the separated (SP) type, and the trabecular (TR) type. For each type, the enhancement of the inner membrane, the outer membrane, and trabeculae was evaluated. Enhancement of the inner membrane develops as the stage of CSDH progresses. Although the inner membrane was not enhanced in the HM type, it was enhanced in almost all of the patients with the other types (p <0.0001). In 13% of patients with the LM type, 29% with the SP type, and 40% with the TR type, the inner membrane was moderately or markedly enhanced. The outer membrane was not thickened in any patient. In 88% of the patients who had contralateral hemiparesis on admission and 42% of those who did not have hemiparesis, the inner membrane was clearly enhanced (p=0.0166). This indicated that blood flow to the inner membrane from the pia matter induced hypoperfusion of the brain parenchyma beneath the hematoma in addition to the effect of direct compression. Contrast CT scanning may be useful for diagnosing the extent of enlargement of the inner membrane, predicting the risk of local brain damage, and evaluating the stage in the natural history of CSDH. (author)

  2. Relationship between the natural history of chronic subdural hematoma and enhancement of the inner membrane on post-contrast CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Nakaguchi, Hiroshi; Yoshimasu, Norio [Teraoka Memorial Hospital, Shinichi, Hiroshima (Japan); Tanishima, Takeo [Tokyo Kosei Nenkin Hospital (Japan)

    2003-02-01

    The purpose of this study was to determine the features and natural history of the inner membrane in CSDH (chronic subdural hemotoma) patients using pre- and post-contrast CT scans. Twenty-four patients with CSDH (28 hematomas) who underwent pre- and post-contrast CT scanning prior to surgery ware studied. CSDH was classified according to the internal architecture as the homogeneous (HM) type, the laminar (LM) type, the separated (SP) type, and the trabecular (TR) type. For each type, the enhancement of the inner membrane, the outer membrane, and trabeculae was evaluated. Enhancement of the inner membrane develops as the stage of CSDH progresses. Although the inner membrane was not enhanced in the HM type, it was enhanced in almost all of the patients with the other types (p <0.0001). In 13% of patients with the LM type, 29% with the SP type, and 40% with the TR type, the inner membrane was moderately or markedly enhanced. The outer membrane was not thickened in any patient. In 88% of the patients who had contralateral hemiparesis on admission and 42% of those who did not have hemiparesis, the inner membrane was clearly enhanced (p=0.0166). This indicated that blood flow to the inner membrane from the pia matter induced hypoperfusion of the brain parenchyma beneath the hematoma in addition to the effect of direct compression. Contrast CT scanning may be useful for diagnosing the extent of enlargement of the inner membrane, predicting the risk of local brain damage, and evaluating the stage in the natural history of CSDH. (author)

  3. Elevated arousal levels enhance contrast perception.

    Science.gov (United States)

    Kim, Dongho; Lokey, Savannah; Ling, Sam

    2017-02-01

    Our state of arousal fluctuates from moment to moment-fluctuations that can have profound impacts on behavior. Arousal has been proposed to play a powerful, widespread role in the brain, influencing processes as far ranging as perception, memory, learning, and decision making. Although arousal clearly plays a critical role in modulating behavior, the mechanisms underlying this modulation remain poorly understood. To address this knowledge gap, we examined the modulatory role of arousal on one of the cornerstones of visual perception: contrast perception. Using a reward-driven paradigm to manipulate arousal state, we discovered that elevated arousal state substantially enhances visual sensitivity, incurring a multiplicative modulation of contrast response. Contrast defines vision, determining whether objects appear visible or invisible to us, and these results indicate that one of the consequences of decreased arousal state is an impaired ability to visually process our environment.

  4. Intravenous contrast enhanced computed tomography colonoscopy in children with suspected colonic polyps

    International Nuclear Information System (INIS)

    Bhatia, Anmol; Saxena, Akshay K.; Kalra, Naveen; Sodhi, Kushaljit S.; Thapa, Babu R.; Rao, Katragadda L.N.; Khandelwal, Niranjan

    2013-01-01

    Objective: The purpose of this study was to evaluate the diagnostic performance of intravenous contrast enhanced computed tomographic colonoscopy (IVCTC) in the diagnosis of clinically suspected colorectal polyps in children, using conventional colonoscopy (CC) as the gold standard. Methods: This was a prospective study conducted between July 2008 and June 2010. 30 pediatric patients with history of rectal bleeding and clinically suspected to have colorectal polyps were enrolled. All of the patients underwent IVCTC followed by CC. 30 IVCTC and 31 CC were performed in 30 patients. The findings of IVCTC were compared with those of CC. Statistical analysis was performed to obtain diagnostic performance values of IVCTC on per polyp (sensitivity and positive predictive value) and per patient (sensitivity, specificity, positive predictive value and negative predictive value) basis. Results: By IVCTC, 63 polyps were detected in 28 patients of which 53 polyps were eligible for inclusion in the statistical analysis. 60 polyps were detected by CC in 28 patients of which 50 polyps were eligible for inclusion in the statistical analysis. The per polyp sensitivity and positive predictive values were 94% and 88.6% respectively. The per patient sensitivity, specificity, positive predictive value, and negative predictive values were 96.4, 50, 96.4, and 50% respectively. Twenty polyps, in 10 patients, were visualized only after intravenous contrast administration of which 5 polyps, in 5 patients, were likely to have been missed in the absence of the intravenous contrast injection as these polyps were submerged in fluid. Four patients would have had a false negative CTC examination if the intravenous contrast had not been injected; while in another patient, the number of polyps would have been underestimated. Conclusion: CTC is capable of serving as a safe and efficient non-invasive tool for evaluating children with clinically suspected colorectal polyps. Administration of

  5. MRI contrast enhancement using Magnetic Carbon Nanoparticles

    Science.gov (United States)

    Chaudhary, Rakesh P.; Kangasniemi, Kim; Takahashi, Masaya; Mohanty, Samarendra K.; Koymen, Ali R.; Department of Physics, University of Texas at Arlington Team; University of Texas Southwestern Medical Center Team

    2014-03-01

    In recent years, nanotechnology has become one of the most exciting forefront fields in cancer diagnosis and therapeutics such as drug delivery, thermal therapy and detection of cancer. Here, we report development of core (Fe)-shell (carbon) nanoparticles with enhanced magnetic properties for contrast enhancement in MRI imaging. These new classes of magnetic carbon nanoparticles (MCNPs) are synthesized using a bottom-up approach in various organic solvents, using the electric plasma discharge generated in the cavitation field of an ultrasonic horn. Gradient echo MRI images of well-dispersed MCNP-solutions (in tube) were acquired. For T2 measurements, a multi echo spin echo sequence was performed. From the slope of the 1/T2 versus concentration plot, the R2 value for different CMCNP-samples was measured. Since MCNPs were found to be extremely non-reactive, and highly absorbing in NIR regime, development of carbon-based MRI contrast enhancement will allow its simultaneous use in biomedical applications. We aim to localize the MCNPs in targeted tissue regions by external DC magnetic field, followed by MRI imaging and subsequent photothermal therapy.

  6. The Incidence, Classification, and Management of Acute Adverse Reactions to the Low-Osmolar Iodinated Contrast Media Isovue and Ultravist in Contrast-Enhanced Computed Tomography Scanning.

    Science.gov (United States)

    Zhang, Bin; Dong, Yuhao; Liang, Long; Lian, Zhouyang; Liu, Jing; Luo, Xiaoning; Chen, Wenbo; Li, Xinyu; Liang, Changhong; Zhang, Shuixing

    2016-03-01

    Some epidemiologic surveillance studies have recorded adverse drug reactions to radiocontrast agents. We aimed to investigate the incidence and management of acute adverse reactions (AARs) to Ultravist-370 and Isovue-370 in patients who underwent contrast-enhanced computed tomography (CT) scanning.Data from 137,473 patients were analyzed. They had undergone enhanced CT scanning with intravenous injection of Ultravist-370 or Isovue-370 during the period of January 1, 2006 to December 31, 2012 in our hospital. We investigated and classified AARs according to the American College of Radiology and the Chinese Society of Radiology (CSR) guidelines for iodinated contrast media. We analyzed risk factors for AARs and compared the AARs induced by Ultravist-370 and Isovue-370.Four hundred and twenty-eight (0.31%) patients experienced AARs, which included 330 (0.24%) patients with mild AARs, 82 (0.06%) patients with moderate AARs, and 16 (0.01%) patients with severe AARs (including 3 cases of cardiac arrest and one case of death). The incidence of AARs was higher with Ultravist-370 than with Isovue-370 (0.38% vs 0.24%, P management, the symptoms and signs of 96.5% of the AARs resolved within 24 hours without sequelae.Ultravist-370 and Isovue-370 are safe for patients undergoing enhanced CT scanning. The incidence of AARs is higher with Ultravist-370 than with Isovue-370, but this difference is limited only to the mild AARs. The incidence of AARs could be affected by multiple factors.

  7. Assessment of chronic thromboembolic pulmonary hypertension by three-dimensional contrast-enhanced MR angiography - comparison with selective intraarterial DSA

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Ley, S.; Kauczor, H.U.; Kalden, P.; Pitton, M.B.; Thelen, M.; Mayer, E.; Laub, G.

    2000-01-01

    Purpose: This study compares contrast-enhanced 3D-MR angiography (MRA) of the pulmonary arteries with selective intraarterial DSA in patients with chronic thromboembolic pulmonary hypertension. Materials and methods: 20 patients preoperatively underwent a contrast-enhanced 3D-MRA of the pulmonary arteries at 1.5 T using the phased-array body coil. For MRA, we used a 3D-Flash-sequence after bolus timing. 2 radiologists analyzed the acquired image material in consensus with respect to the detection of central thromboembolic material and the visualization of the pulmonary arterial tree. Finally, the MR angiograms were compared with selective DSA images using surgical findings as the definitive standard. Results: MRA demonstrated central thromboembolic material, vessel cut-offs and abnormal proximal-to-distal tapering in all patients. Compared to DSA, MRA depicted the pulmonary vessels up to the segmental level in all cases, it was inferior to DSA in delineation of the subsegmental arteries (sensitivity 87%, specificity 100%). The central beginning of the thromboembolic occlusions seen at MRA corresponded to the beginning of the deobliteration procedure during pulmonary thromboendarterectomy in every case. (orig.) [de

  8. Prevalence and characteristics of intravertebral enhancement on contrast-enhanced CT scans in cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Rasselet, Benjamin [Medical Imaging Department and Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France); Larbi, Ahmed; Viala, Pierre [Medical Imaging Department, Nimes University Hospital, 4 rue du Professeur Robert Debré, 30029 Nîmes (France); Molinari, Nicolas [Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France); Tetreau, Raphael [Medical Imaging Department, Montpellier Cancer Institute (ICM), 208 Avenue des Apothicaires, 34298 Montpellier Cedex 5 (France); Faruch-Bilfeld, Marie [Medical Imaging Department, Toulouse University Hospital, Place du Docteur Baylac, 31059 Toulouse Cedex 9 (France); Taourel, Patrice [Medical Imaging Department and Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France); Cyteval, Catherine, E-mail: c-cyteval@chu-montpellier.fr [Medical Imaging Department and Biostatistics Department, Montpellier University Hospital, 191 Avenue du Doyen Gaston Giraud, 34 295 Montpellier Cedex 5 (France)

    2017-01-15

    Highlights: • 2.8% of collateral venous circulation seen on CT scan in a cancer population. • 37% of intravertebral enhancement in this population with collateral venous circulation. • 80.8% of intravertebral enhancements are located between C6 and. • 73% of intravertebral enhancements are located ipsilateral to the injection side. -  Abstract: Study design: This was a single center, retrospective observational study. Objective: to investigate—in a cancer population—the prevalence and hallmarks of intravertebral enhancement (IVE) detected on contrast-enhanced CT. Summary of background data: Intravertebral enhancements secondary to iodinated contrast stagnation have been described. Cancer patients have an increased risk of perivertebral venous thrombosis or stenosis secondary to several risk factors (cancer or drug induced hypercoagulability, deterioration of venous flow linked to catheter insertion, prolonged immobilization). In case of a high density lesion identified on CT, the diagnostic choice between metastasis and contrast media within bone marrow vessels may be an issue, especially as oncologic follow-up CT scans are usually performed with contrast medium injection. Methods: 2572 contrast-enhanced body CT scans performed in cancer patients over 3 months in the medical imaging department of a university hospital were retrospectively reviewed. IVE was sought when paravertebral venous collateral circulation was detected and bone metastasis ruled out and classified as linear or nodular. Their locations within vertebra, their relation to the injection side and the predominant collateral venous network side were evaluated. Results: Sixty-seven (2.8%) patients had a collateral paravertebral venous system and among them 21 had IVE (37%). There were 208 IVE locations involving 75 vertebrae. 199 IVE were linear-shaped (95.7%) and 9 nodular-shaped (4.3%). 80.8% were located between C6 and T4. 88.9% were localized in the vertebral body. 73.1% were located

  9. Prevalence and characteristics of intravertebral enhancement on contrast-enhanced CT scans in cancer patients

    International Nuclear Information System (INIS)

    Rasselet, Benjamin; Larbi, Ahmed; Viala, Pierre; Molinari, Nicolas; Tetreau, Raphael; Faruch-Bilfeld, Marie; Taourel, Patrice; Cyteval, Catherine

    2017-01-01

    Highlights: • 2.8% of collateral venous circulation seen on CT scan in a cancer population. • 37% of intravertebral enhancement in this population with collateral venous circulation. • 80.8% of intravertebral enhancements are located between C6 and. • 73% of intravertebral enhancements are located ipsilateral to the injection side. -  Abstract: Study design: This was a single center, retrospective observational study. Objective: to investigate—in a cancer population—the prevalence and hallmarks of intravertebral enhancement (IVE) detected on contrast-enhanced CT. Summary of background data: Intravertebral enhancements secondary to iodinated contrast stagnation have been described. Cancer patients have an increased risk of perivertebral venous thrombosis or stenosis secondary to several risk factors (cancer or drug induced hypercoagulability, deterioration of venous flow linked to catheter insertion, prolonged immobilization). In case of a high density lesion identified on CT, the diagnostic choice between metastasis and contrast media within bone marrow vessels may be an issue, especially as oncologic follow-up CT scans are usually performed with contrast medium injection. Methods: 2572 contrast-enhanced body CT scans performed in cancer patients over 3 months in the medical imaging department of a university hospital were retrospectively reviewed. IVE was sought when paravertebral venous collateral circulation was detected and bone metastasis ruled out and classified as linear or nodular. Their locations within vertebra, their relation to the injection side and the predominant collateral venous network side were evaluated. Results: Sixty-seven (2.8%) patients had a collateral paravertebral venous system and among them 21 had IVE (37%). There were 208 IVE locations involving 75 vertebrae. 199 IVE were linear-shaped (95.7%) and 9 nodular-shaped (4.3%). 80.8% were located between C6 and T4. 88.9% were localized in the vertebral body. 73.1% were located

  10. TMJ disorders and pain: Assessment by contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Farina, Davide; Bodin, Christiane; Gandolfi, Silvia; De Gasperi, Werner; Borghesi, Andrea; Maroldi, Roberto

    2009-01-01

    Though magnetic resonance (MRI) is a widely accepted standard for the assessment of patients with temporomandibular joint (TMJ) disorders, efforts to correlate symptoms to MRI findings have often given controversial results. Aim of this study was to investigate the correlation between TMJ pain and findings of contrast-enhanced MRI. Thirty-eight consecutive patients with TMJ dysfunction syndrome (study group) were examined with MRI. Protocol included T2 turbo spin-echo sequence, T1 spin-echo sequence, and T2 gradient-echo (acquired with closed jaw, at intermediate and maximal opening). Post-contrast phase was obtained through a fat sat 3D T1 gradient-echo sequence (VIBE). Post-contrast findings in the study group were matched with those obtained in a control group of 33 patients submitted to MRI of the paranasal sinuses. Statistically significant difference was found between condylar medullary bone enhancement in painful TMJ, in painless TMJ and control group. In addition the average thickness of joint soft tissue enhancement in painful TMJ was superior to painless TMJ (p < 0.0001) and to control group. On multivariate logistic regression analysis, the odds ratio that a painful TMJ showed disk displacement, osteoarthrosis, effusion and JST enhancement were 3.05, 3.18, 1.2 and 11.36, respectively. Though not histologically proven, TMJ enhancement could reflect the presence of inflammation in painful joints. Furthermore, the administration of contrast could be of help for the assessment of patients with orofacial pain, particularly when clinical exploration is insufficient to ascribe the pain to TMJ.

  11. TMJ disorders and pain: Assessment by contrast-enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Davide [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); Bodin, Christiane [Division of Gnathology (School of Dentistry), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); Gandolfi, Silvia [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); De Gasperi, Werner [Division of Gnathology (School of Dentistry), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); Borghesi, Andrea; Maroldi, Roberto [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy)

    2009-04-15

    Though magnetic resonance (MRI) is a widely accepted standard for the assessment of patients with temporomandibular joint (TMJ) disorders, efforts to correlate symptoms to MRI findings have often given controversial results. Aim of this study was to investigate the correlation between TMJ pain and findings of contrast-enhanced MRI. Thirty-eight consecutive patients with TMJ dysfunction syndrome (study group) were examined with MRI. Protocol included T2 turbo spin-echo sequence, T1 spin-echo sequence, and T2 gradient-echo (acquired with closed jaw, at intermediate and maximal opening). Post-contrast phase was obtained through a fat sat 3D T1 gradient-echo sequence (VIBE). Post-contrast findings in the study group were matched with those obtained in a control group of 33 patients submitted to MRI of the paranasal sinuses. Statistically significant difference was found between condylar medullary bone enhancement in painful TMJ, in painless TMJ and control group. In addition the average thickness of joint soft tissue enhancement in painful TMJ was superior to painless TMJ (p < 0.0001) and to control group. On multivariate logistic regression analysis, the odds ratio that a painful TMJ showed disk displacement, osteoarthrosis, effusion and JST enhancement were 3.05, 3.18, 1.2 and 11.36, respectively. Though not histologically proven, TMJ enhancement could reflect the presence of inflammation in painful joints. Furthermore, the administration of contrast could be of help for the assessment of patients with orofacial pain, particularly when clinical exploration is insufficient to ascribe the pain to TMJ.

  12. The added value of {sup 68}Ga-DOTA-TATE-PET to contrast-enhanced CT for primary site detection in CUP of neuroendocrine origin

    Energy Technology Data Exchange (ETDEWEB)

    Kazmierczak, Philipp M. [Klinikum der Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Muenchen (Germany); Rominger, Axel; Wenter, Vera [Ludwig-Maximilians-University Hospital Munich, Department of Nuclear Medicine, Muenchen (Germany); Spitzweg, Christine; Auernhammer, Christoph [Ludwig-Maximilians-University Hospital Munich, Department of Internal Medicine II, Muenchen (Germany); Angele, Martin K. [Ludwig-Maximilians-University Hospital Munich, Department of General, Visceral, Transplantation, Vascular and Thoracic Surgery, Muenchen (Germany); Rist, Carsten; Cyran, Clemens C. [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Muenchen (Germany)

    2017-04-15

    To quantify the additional value of {sup 68}Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced {sup 68}Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and {sup 68}Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up {sup 68}Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p < 0.001). {sup 68}Ga-DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. (orig.)

  13. Right and Left Ventricular Function and Mass in Male Elite Master Athletes: A Controlled Contrast-Enhanced Cardiovascular Magnetic Resonance Study.

    Science.gov (United States)

    Bohm, Philipp; Schneider, Günther; Linneweber, Lutz; Rentzsch, Axel; Krämer, Nadine; Abdul-Khaliq, Hashim; Kindermann, Wilfried; Meyer, Tim; Scharhag, Jürgen

    2016-05-17

    It is under debate whether the cumulative effects of intensive endurance exercise induce chronic cardiac damage, mainly involving the right heart. The aim of this study was to examine the cardiac structure and function in long-term elite master endurance athletes with special focus on the right ventricle by contrast-enhanced cardiovascular magnetic resonance. Thirty-three healthy white competitive elite male master endurance athletes (age range, 30-60 years) with a training history of 29±8 years, and 33 white control subjects pair-matched for age, height, and weight underwent cardiopulmonary exercise testing, echocardiography including tissue-Doppler imaging and speckle tracking, and cardiovascular magnetic resonance. Indexed left ventricular mass and right ventricular mass (left ventricular mass/body surface area, 96±13 and 62±10 g/m(2); Pright ventricular mass/body surface area, 36±7 and 24±5 g/m(2); Pleft ventricular end-diastolic volume and right ventricular end-diastolic volume (left ventricular end-diastolic volume/body surface area, 104±13 and 69±18 mL/m(2); Pright ventricular end-diastolic volume/body surface area, 110±22 and 66±16 mL/m(2); PRight ventricular ejection fraction did not differ between athletes and control subjects (52±8 and 54±6%; P=0.26). Pathological late enhancement was detected in 1 athlete. No correlations were found for left ventricular and right ventricular volumes and ejection fraction with N-terminal pro-brain natriuretic peptide, and high-sensitive troponin was negative in all subjects. Based on our results, chronic right ventricular damage in elite endurance master athletes with lifelong high training volumes seems to be unlikely. Thus, the hypothesis of an exercise-induced arrhythmogenic right ventricular cardiomyopathy has to be questioned. © 2016 American Heart Association, Inc.

  14. Reproducibility of contrast-enhanced transrectal ultrasound of the prostate

    NARCIS (Netherlands)

    Sedelaar, J. P.; Goossen, T. E.; Wijkstra, H.; de la Rosette, J. J.

    2001-01-01

    Transrectal three-dimensional (3-D) contrast-enhanced power Doppler ultrasound (US) is a novel technique for studying possible prostate malignancy. Before studies can be performed to investigate the clinical validity of the technique, reproducibility of the contrast US studies must be proven.

  15. Contrast enhancement of focal hepatic lesions in CT: effect of size and histology

    International Nuclear Information System (INIS)

    Burgener, F.A.; Hamlin, D.J.

    1983-01-01

    The effect of size and histology on the contrast enhancement of hepatic lesions has been analyzed in this clinical and experimental investigation yielding the following results: (1) The attenuation values of hepatic cysts in patients increase significantly and inversely with their size after contrast enhancement when the cysts measure less than twice the CT-slice thickness. This seems to be caused by partial-volume effect. (2) Experimental tumors of identical sizes and originating from the same cell line can demonstrate different contrast-enhancement patterns. (3) Peak contrast uptake in both experimental and human tumors seems to be inversely related to their size. (4) Compared to liver, contrast washout from experimental and human tumors (presumably the extravascular space) is delayed. The delay in the contrast washout from a tumor seems to correlate with tumor size. These findings suggest that in general, it is not possible to differentiate reliably among various hepatic neoplasms on the basis of their contrast enhancement patterns for the following reasons: (1) Attenuation values of small hepatic neoplasms are distorted by partial volume effect. (2) Tumors of different histologies can demonstrate the same enhancement pattern. (3) Tumors of identical histology and size can demonstrate different enhancement patterns. (4) The enhancement pattern of a tumor changes with growth or size

  16. Contrast enhanced ultrasound in the assessment of urogenital pathology

    Directory of Open Access Journals (Sweden)

    Libero Barozzi

    2014-12-01

    Full Text Available Contrast enhanced ultrasound (CEUS is an innovative technique that employs microbubble contrast agents to demonstrate parenchymal perfusion. Although initial clinical application was focused on the liver pathology, a wide variety of clinical conditions can be assessed now with CEUS. CEUS is a well-tolerated technique and is acquiring an increasing role in the assessment of renal pathology because contrast agents are not excreted by the kidney and do not affect the renal function. CEUS demonstrated an accuracy similar to contrast enhanced multi-detector computed tomography (CEMDCT in detecting focal lesions, with the advantage of the real-time assessment of microvascular perfusion by using time-intensity curves. The aim of this paper is to review the main indications of CEUS in the assessment of renal and urogenital pathology. Imaging examples are presented and described. Advantages and limitations of CEUS with reference to conventional US and CE-MDCT are discussed.

  17. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Kim, Tae Kyoung; Khalili, Korosh [University of Toronto, Department of Medical Imaging, University Health Network, Toronto, ON (Canada); Bae, Mi Hyun; Lee, Joo Yeon [University of Ulsan College of Medicine, Seoul (Korea); Lee, Sung-Gyu [University of Ulsan College of Medicine, Asan Medical Center, Division of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, Seoul (Korea); Yu, Eun Sil [University of Ulsan College of Medicine, Asan Medical Center, Department of Diagnostic Pathology, Seoul (Korea)

    2010-02-15

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ({sub pre} L-S) and contrast-enhanced ({sub post} L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ({sub post} L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for{sub pre} L-S,{sub post} L-S and{sub post} L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of{sub pre} L-S and{sub post} L-S did not differ (P {>=} 0.054), despite a trend towards a lower accuracy with{sub post} L-S.{sub post} L-B yielded higher accuracy than{sub pre} L-S at threshold levels of 5% and 10% (P {<=} 0.002) and similar accuracy to{sub pre} L-S at the other threshold levels (P {>=} 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  18. Abnormal contrast enhancement after the removal of meningioma

    Energy Technology Data Exchange (ETDEWEB)

    Soutsu, M; Hashimoto, T; Yamaguchi, Y; Sekino, H; Nakamura, N [Jikei Univ., Tokyo (Japan). School of Medicine

    1980-12-01

    Since the introduction of Computerized Tomography (CT) in August, 1976, we have had experience with 20 patients with meningioma. In 10 patients out of the 20, the tumors were removed totally and examined by contrast-enhanced CT pre- and postoperatively. In spite of the total removal of the tumor, however, 5 patients showed an unexpected abnormal enhancement at the operated site after the infusion of a contrast material. These changes were relatively intense, so it was suspected that there were residual tumors. Comparing these 5 cases with the remaining 5 that had no postoperative enhancement, the former cases were shown by operative and angiographical findings to have more adhesion and connecting vessels between tumor and cortex. Since such a postoperative abnormal enhancement is seen along the corticotomy or retracted area after operations for and aneurysm or another lesion, damaged brain tissue was though to be the probable reason for this enhancement. Moreover, the circulatory change caused by cutting the connecting vessels between tumor and cortex was considered to be another reason for the enhancement. This mechanism was also considered to be one reason for the post-meningioma syndrome by El-Banhawy. These postoperative enhancements decreased in density and became obscure within 4 or 8 weeks. Any reappearance of such changes after that period should be examined, carefully to determine whether or not it marks a recurrent tumor.

  19. Gd-based Contrast Enhancement of the Perivascular Spaces in the Basal Ganglia.

    Science.gov (United States)

    Naganawa, Shinji; Nakane, Toshiki; Kawai, Hisashi; Taoka, Toshiaki

    2017-01-10

    In textbooks, the perivascular space (PVS) is described as non-enhancing after the intravenous administration of gadolinium-based contrast agent (IV-GBCA). We noticed that the PVS sometimes has high signal intensity (SI) on heavily T 2 -weighted 3D-FLAIR (hT 2 -FL) images obtained 4 h after IV-GBCA. The purpose of this study was to retrospectively evaluate the contrast enhancement of the PVS. In 8 healthy subjects and 19 patients with suspected endolymphatic hydrops, magnetic resonance cisternography (MRC) and hT 2 -FL images were obtained before and 4 h after a single dose of IV-GBCA. No subjects had renal insufficiency. On axial MRC at the level of the anterior commissure (AC)-posterior commissure (PC) line, 1 cm circular regions of interest (ROIs) were drawn centering on the PVS in the bilateral basal ganglia and thalami. Three-millimeter diameter ROIs were set in the cerebrospinal fluid (CSF) of the bilateral ambient cistern. The ROIs on MRC were copied onto the hT 2 -FL images and the SI was measured. The SI ratio (SIR) was defined as SIR PVS = SI of PVS/SI of the thalami, and SIR CSF = SI of CSF/SI of the thalami. The average of the bilateral values was used for the calculation. The SIR CSF , SIR PVS , and SI of the thalami were compared between before and 4 h after IV-GBCA. The SIR was increased significantly from 1.02 ± 0.37 to 2.65 ± 0.82 in the CSF (P glymphatic system (waste clearance system) of the brain.

  20. Evaluation of liver parenchyma and perfusion using dynamic contrast-enhanced computed tomography and contrast-enhanced ultrasonography in captive green iguanas (Iguana iguana) under general anesthesia.

    Science.gov (United States)

    Nardini, Giordano; Di Girolamo, Nicola; Leopardi, Stefania; Paganelli, Irene; Zaghini, Anna; Origgi, Francesco C; Vignoli, Massimo

    2014-05-13

    Contrast-enhanced diagnostic imaging techniques are considered useful in veterinary and human medicine to evaluate liver perfusion and focal hepatic lesions. Although hepatic diseases are a common occurrence in reptile medicine, there is no reference to the use of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) to evaluate the liver in lizards. Therefore, the aim of this study was to evaluate the pattern of change in echogenicity and attenuation of the liver in green iguanas (Iguana iguana) after administration of specific contrast media. An increase in liver echogenicity and density was evident during CEUS and CECT, respectively. In CEUS, the mean ± SD (median; range) peak enhancement was 19.9% ± 7.5 (18.3; 11.7-34.6). Time to peak enhancement was 134.0 ± 125.1 (68.4; 59.6-364.5) seconds. During CECT, first visualization of the contrast medium was at 3.6 ± 0.5 (4; 3-4) seconds in the aorta, 10.7 ± 2.2 (10.5; 7-14) seconds in the hepatic arteries, and 15 ± 4.5 (14.5; 10-24) seconds in the liver parenchyma. Time to peak was 14.1 ± 3.4 (13; 11-21) and 31 ± 9.6 (29; 23-45) seconds in the aorta and the liver parenchyma, respectively. CEUS and dynamic CECT are practical means to determine liver hemodynamics in green iguanas. Distribution of contrast medium in iguana differed from mammals. Specific reference ranges of hepatic perfusion for diagnostic evaluation of the liver in iguanas are necessary since the use of mammalian references may lead the clinician to formulate incorrect diagnostic suspicions.

  1. Independent component analysis of dynamic contrast-enhanced computed tomography images

    Energy Technology Data Exchange (ETDEWEB)

    Koh, T S [School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Ave, Singapore 639798 (Singapore); Yang, X [School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Ave, Singapore 639798 (Singapore); Bisdas, S [Department of Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University Hospital, Theodor-Stern-Kai 7, D-60590 Frankfurt (Germany); Lim, C C T [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-10-07

    Independent component analysis (ICA) was applied on dynamic contrast-enhanced computed tomography images of cerebral tumours to extract spatial component maps of the underlying vascular structures, which correspond to different haemodynamic phases as depicted by the passage of the contrast medium. The locations of arteries, veins and tumours can be separately identified on these spatial component maps. As the contrast enhancement behaviour of the cerebral tumour differs from the normal tissues, ICA yields a tumour component map that reveals the location and extent of the tumour. Tumour outlines can be generated using the tumour component maps, with relatively simple segmentation methods. (note)

  2. Quantitative analysis of enhanced malignant and benign lesions on contrast-enhanced spectral mammography.

    Science.gov (United States)

    Deng, Chih-Ying; Juan, Yu-Hsiang; Cheung, Yun-Chung; Lin, Yu-Ching; Lo, Yung-Feng; Lin, GiGin; Chen, Shin-Cheh; Ng, Shu-Hang

    2018-02-27

    To retrospectively analyze the quantitative measurement and kinetic enhancement among pathologically proven benign and malignant lesions using contrast-enhanced spectral mammography (CESM). We investigated the differences in enhancement between 44 benign and 108 malignant breast lesions in CESM, quantifying the extent of enhancements and the relative enhancements between early (between 2-3 min after contrast medium injection) and late (3-6 min) phases. The enhancement was statistically stronger in malignancies compared to benign lesions, with good performance by the receiver operating characteristic curve [0.877, 95% confidence interval (0.813-0.941)]. Using optimal cut-off value at 220.94 according to Youden index, the sensitivity was 75.9%, specificity 88.6%, positive likelihood ratio 6.681, negative likelihood ratio 0.272 and accuracy 82.3%. The relative enhancement patterns of benign and malignant lesions, showing 29.92 vs 73.08% in the elevated pattern, 7.14 vs 92.86% in the steady pattern, 5.71 vs 94.29% in the depressed pattern, and 80.00 vs 20.00% in non-enhanced lesions (p < 0.0001), respectively. Despite variations in the degree of tumour angiogenesis, quantitative analysis of the breast lesions on CESM documented the malignancies had distinctive stronger enhancement and depressed relative enhancement patterns than benign lesions. Advances in knowledge: To our knowledge, this is the first study evaluating the feasibility of quantifying lesion enhancement on CESM. The quantities of enhancement were informative for assessing breast lesions in which the malignancies had stronger enhancement and more relative depressed enhancement than the benign lesions.

  3. Dynamic contrast-enhanced MR imaging in predicting progression of enhancing lesions persisting after standard treatment in glioblastoma patients: a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Roh-Eul; Choi, Hye Jeong; You, Sung-Hye; Kang, Koung Mi; Yun, Tae Jin; Kim, Ji-Hoon; Sohn, Chul-Ho [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Choi, Seung Hong [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University, Center for Nanoparticle Research, Institute for Basic Science, and School of Chemical and Biological Engineering, Seoul (Korea, Republic of); Seoul National University, School of Chemical and Biological Engineering, Seoul (Korea, Republic of); Kim, Tae Min [Seoul National University College of Medicine, Department of Internal Medicine, Cancer Research Institute, Seoul (Korea, Republic of); Park, Chul-Kee [Seoul National University College of Medicine, Department of Neurosurgery, Biomedical Research Institute, Seoul (Korea, Republic of); Park, Sung-Hye; Won, Jae-Kyung [Seoul National University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Kim, Il Han [Seoul National University College of Medicine, Department of Radiation Oncology, Cancer Research Institute, Seoul (Korea, Republic of); Lee, Soon Tae [Seoul National University College of Medicine, Department of Neurology, Seoul (Korea, Republic of)

    2017-08-15

    To prospectively explore the value of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in predicting the progression of enhancing lesions persisting after standard treatment in patients with surgically resected glioblastoma (GBM). Forty-seven GBM patients, who underwent near-total tumorectomy followed by concurrent chemoradiation therapy (CCRT) with temozolomide (TMZ) between May 2014 and February 2016, were enrolled. Twenty-four patients were finally analyzed for measurable enhancing lesions persisting after standard treatment. DCE-MRI parameters were calculated at enhancing lesions. Mann-Whitney U tests and multivariable stepwise logistic regression were used to compare parameters between progression (n = 16) and non-progression (n = 8) groups. Mean K{sup trans} and v{sub e} were significantly lower in progression than in non-progression (P = 0.037 and P = 0.037, respectively). The 5th percentile of the cumulative K{sup trans} histogram was also significantly lower in the progression than in non-progression group (P = 0.017). Mean v{sub e} was the only independent predictor of progression (P = 0.007), with a sensitivity of 100%, specificity of 63%, and an overall accuracy of 88% at a cut-off value of 0.873. DCE-MRI may help predict the progression of enhancing lesions persisting after the completion of standard treatment in patients with surgically resected GBM, with mean v{sub e} serving as an independent predictor of progression. (orig.)

  4. Dynamic contrast-enhanced MR imaging in predicting progression of enhancing lesions persisting after standard treatment in glioblastoma patients: a prospective study

    International Nuclear Information System (INIS)

    Yoo, Roh-Eul; Choi, Hye Jeong; You, Sung-Hye; Kang, Koung Mi; Yun, Tae Jin; Kim, Ji-Hoon; Sohn, Chul-Ho; Choi, Seung Hong; Kim, Tae Min; Park, Chul-Kee; Park, Sung-Hye; Won, Jae-Kyung; Kim, Il Han; Lee, Soon Tae

    2017-01-01

    To prospectively explore the value of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in predicting the progression of enhancing lesions persisting after standard treatment in patients with surgically resected glioblastoma (GBM). Forty-seven GBM patients, who underwent near-total tumorectomy followed by concurrent chemoradiation therapy (CCRT) with temozolomide (TMZ) between May 2014 and February 2016, were enrolled. Twenty-four patients were finally analyzed for measurable enhancing lesions persisting after standard treatment. DCE-MRI parameters were calculated at enhancing lesions. Mann-Whitney U tests and multivariable stepwise logistic regression were used to compare parameters between progression (n = 16) and non-progression (n = 8) groups. Mean K trans and v e were significantly lower in progression than in non-progression (P = 0.037 and P = 0.037, respectively). The 5th percentile of the cumulative K trans histogram was also significantly lower in the progression than in non-progression group (P = 0.017). Mean v e was the only independent predictor of progression (P = 0.007), with a sensitivity of 100%, specificity of 63%, and an overall accuracy of 88% at a cut-off value of 0.873. DCE-MRI may help predict the progression of enhancing lesions persisting after the completion of standard treatment in patients with surgically resected GBM, with mean v e serving as an independent predictor of progression. (orig.)

  5. The cerebral intravascular enhancement sign is not specific: a contrast-enhanced MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Bakshi, R.; Kinkel, W.R.; Bates, V.E.; Mechtler, L.L.; Kinkel, P.R. [Lucy Dent Imaging Center, University at Buffalo, NY (United States)

    1999-02-01

    The intravascular enhancement (IVE) sign, also known as the ``arterial enhancement sign``, is an abnormal finding in the brain on contrast-enhanced MRI studies. IVE has been described in arterial cerebrovascular disorders, most commonly in acute or subacute arterial ischemic infarcts. However, the specificity of this sign has not been established. We describe four patients with disorders other than arterial strokes in whom gadolinium-enhanced high-field (1.5 T) MRI suggested IVE. The conditions were herpes simplex viral encephalitis, idiopathic cerebellitis, pneumococcal meningitis, and superior sagittal sinus thrombosis with venous infarction. IVE in these cases may be due to multiple factors, including arterial, venous, perivascular, and leptomeningeal or sulcal contrast medium accumulation. Our observations suggest that arterial ischemia, previously described as the cardinal cause of IVE, probably does not explain all instances, and urge caution in interpreting this sign as a specific MRI manifestation of acute arterial infarction or ischemia. (orig.) With 4 figs., 1 tab., 44 refs.

  6. MRI contrast enhancement of the lung using a Gd-DTPA aerosol

    International Nuclear Information System (INIS)

    Bockisch, A.; Harvey, R.C.; Davis, M.A.; Kabalka, G.W.

    1993-01-01

    A MR imaging study was performed in anesthetized female beagle dogs to investigate the effectiveness of Gd-DTPA aerosol for contrast enhancement in ventilated lungs. Ventilation was performed using a commercially available atomizer to administer Gd-DTPA solution. MR imaging was performed with a 1.9 T whole body imager using respiratory gated acquisition. To define the amount of Gd-DTPA being trapped in the lungs identical experiments were performed with 99m Tc-DTPA. MR imaging confirmed at 70% contrast enhancement following inhalation of Gd-DTPA. Because of the inherently low signal intensity of lung parenchyma the degree of contrast enhancement is not sufficient for clinical application. (orig.) [de

  7. Radiofrequency ablation of liver cancer: early evaluation of therapeutic response with contrast-enhanced ultrasonography

    International Nuclear Information System (INIS)

    Choi, Dong Gil; Lim, Hyo K.; Lee, Won Jae; Kim, Seung Hoon; Kim, Min Ju; Kim, Seung Kwon; Jang, Kyung Mi; Lee, Ji Yeon; Lim, Jae Hoon

    2004-01-01

    The early assessment of the therapeutic response after percutaneous radiofrequency (RF) ablation is important, in order to correctly decide whether further treatment is necessary. The residual unablated tumor is usually depicted on contrast-enhanced multiphase helical computed tomography (CT) as a focal enhancing structure during the arterial and portal venous phases. Contrast-enhanced color Doppler and power Doppler ultrasonography (US) have also been used to detect residual tumors. Contrast-enhanced gray-scale US, using a harmonic technology which has recently been introduced, allows for the detection of residual tumors after ablation, without any of the blooming or motion artifacts usually seen on contrast-enhanced color or power Doppler US. Based on our experience and reports in the literature, we consider that contrast-enhanced gray-scale harmonic US constitutes a reliable alternative to contrast-enhanced multiphase CT for the early evaluation of the therapeutic response to RF ablation for liver cancer. This technique was also useful in targeting any residual unablated tumors encountered during additional ablation

  8. Ingestible roasted barley for contrast-enhanced photoacoustic imaging in animal and human subjects.

    Science.gov (United States)

    Wang, Depeng; Lee, Dong Hyeun; Huang, Haoyuan; Vu, Tri; Lim, Rachel Su Ann; Nyayapathi, Nikhila; Chitgupi, Upendra; Liu, Maggie; Geng, Jumin; Xia, Jun; Lovell, Jonathan F

    2018-08-01

    Photoacoustic computed tomography (PACT) is an emerging imaging modality. While many contrast agents have been developed for PACT, these typically cannot immediately be used in humans due to the lengthy regulatory process. We screened two hundred types of ingestible foodstuff samples for photoacoustic contrast with 1064 nm pulse laser excitation, and identified roasted barley as a promising candidate. Twenty brands of roasted barley were further screened to identify the one with the strongest contrast, presumably based on complex chemical modifications incurred during the roasting process. Individual roasted barley particles could be detected through 3.5 cm of chicken-breast tissue and through the whole hand of healthy human volunteers. With PACT, but not ultrasound imaging, a single grain of roasted barley was detected in a field of hundreds of non-roasted particles. Upon oral administration, roasted barley enabled imaging of the gut and peristalsis in mice. Prepared roasted barley tea could be detected through 2.5 cm chicken breast tissue. When barley tea was administered to humans, photoacoustic imaging visualized swallowing dynamics in healthy volunteers. Thus, roasted barley represents an edible foodstuff that should be considered for photoacoustic contrast imaging of swallowing and gut processes, with immediate potential for clinical translation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Analysis of peritumoral edema and contrast enhancement by computerized axial tomography

    International Nuclear Information System (INIS)

    Oi, Shizuo; Szper, I.; Wetzel, N.; Kim, Kwang-S.

    1980-01-01

    For the purpose of treating brain tumors satisfactorily with steroids, CT findings of brain tumors were analyzed, and pathogenesis of peritumoral edema and supposed effects of steroids were investigated. The degree of peritumoral edema and contrast enhancement and their relationship were analyzed in total 201 patients with brain tumors (gliomas, meningiomas, and metastatic brain tumors). As a result, significant peritumoral edema was recognized in 59% of patients with metastatic brain tumors, 46% of patients with glioma, and 34% of patients with meningioma. As a rule, there was a relationship between peritumoral edema and malignancy or localization of braiin tumors. Severe peritumoral edema was observed in malignant supratentorial tumors (over 60%), but peritumoral edema which was found in infratentorial tumors benign gliomas was mild. The degree of contrast enhancement differed according to tumors, and there was not always a relationship between the degree of contrast enhancement and malignancy or localization of brain tumors. CT findings of brain tumors after the administration of steroids showed decrease in the degree of contrast enhancement. Judging from the effect of steroids to inhibit increased vascular permeability associated with brain edema, like CT findings of peritumoral edema, the degree of contrast enhancement which probably expressed vascularity or vascular permeability seemed to be important in deciding the indications for steroid administration. (Tsunoda, M.)

  10. Feature and Contrast Enhancement of Mammographic Image Based on Multiscale Analysis and Morphology

    Directory of Open Access Journals (Sweden)

    Shibin Wu

    2013-01-01

    Full Text Available A new algorithm for feature and contrast enhancement of mammographic images is proposed in this paper. The approach bases on multiscale transform and mathematical morphology. First of all, the Laplacian Gaussian pyramid operator is applied to transform the mammography into different scale subband images. In addition, the detail or high frequency subimages are equalized by contrast limited adaptive histogram equalization (CLAHE and low-pass subimages are processed by mathematical morphology. Finally, the enhanced image of feature and contrast is reconstructed from the Laplacian Gaussian pyramid coefficients modified at one or more levels by contrast limited adaptive histogram equalization and mathematical morphology, respectively. The enhanced image is processed by global nonlinear operator. The experimental results show that the presented algorithm is effective for feature and contrast enhancement of mammogram. The performance evaluation of the proposed algorithm is measured by contrast evaluation criterion for image, signal-noise-ratio (SNR, and contrast improvement index (CII.

  11. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is an x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  12. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  13. Delayed contrast-enhanced computed tomography in patients with known or suspected cardiac sarcoidosis: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Aikawa, Tadao; Naya, Masanao; Obara, Masahiko [Hokkaido University Graduate School of Medicine, Sapporo (Japan); Oyama-Manabe, Noriko; Kudo, Kohsuke [Hokkaido University Hospital, Department of Diagnostic and Interventional Radiology, Sapporo (Japan); Ohira, Hiroshi; Sugimoto, Ayako; Tsujino, Ichizo [Hokkaido University Graduate School of Medicine, First Department of Medicine, Sapporo (Japan); Manabe, Osamu; Tamaki, Nagara [Hokkaido University Graduate School of Medicine, Department of Nuclear Medicine, Sapporo (Japan); Tsutsui, Hiroyuki [Kyushu University, Department of Cardiovascular Medicine, Fukuoka (Japan)

    2017-10-15

    To evaluate the diagnostic value of delayed contrast-enhanced computed tomography (DE-CT) for cardiac sarcoidosis (CS) in patients with or without implantable devices, including a quantitative comparison with late gadolinium enhancement cardiac magnetic resonance (LGE-CMR). Twenty-four patients (mean age, 64 ± 9 years; 17 women) with known or suspected CS underwent retrospective electrocardiogram-gated DE-CT at 80 kV with knowledge-based iterative model reconstruction. Fourteen patients without implantable devices also underwent LGE-CMR, while ten with pacemakers or implantable cardioverter-defibrillators did not. The presence of hyperenhanced myocardium was assessed visually and quantitatively using a 5-standard deviation threshold above the mean of remote myocardium. Inter-observer agreement for visual detection of hyperenhanced segments on DE-CT was excellent in patients with implantable devices and in those without (κ = 0.91 and κ = 0.94, respectively). Comparisons of the percent area of hyperenhanced myocardium between DE-CT and LGE-CMR on both per-patient and per-segment analyses showed good correlations (r = 0.96 and r = 0.83, respectively; p < 0.001). The sensitivity and specificity of DE-CT for the diagnosis of CS were 94% and 33%. The extent of hyperenhanced lesion with DE-CT showed good agreement with LGE-CMR results. DE-CT showed high sensitivity for detecting CS and may be useful particularly in patients with contraindications to CMR. (orig.)

  14. Baseline incidence and severity of renal insufficiency evaluated by estimated glomerular filtration rates in patients scheduled for contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Utsunomiya, Daisuke; Yanaga, Yumi; Oda, Seitaro; Namimoto, Tomohiro; Yamashita, Yasuyuki (Dept. of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto Univ., Kumamoto (Japan)), email: utsunomi@kumamoto-u.ac.jp; Awai, Kazuo (Dept. of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima Univ., Hiroshima (Japan)); Funama, Yoshinori (Dept. of Medical Physics, Faculty of Life Sciences, Kumamoto Univ., Kumamoto (Japan))

    2011-06-15

    Background Although pre-existing renal insufficiency (RI) is the most important risk factor for contrast-induced nephropathy (CIN), the background distribution of baseline renal function has not been investigated thoroughly in patients scheduled for contrast-enhanced CT. Purpose To investigate the incidence and severity of baseline RI evaluated by estimated glomerular filtration rates (eGFR) in patients who underwent contrast-enhanced CT at an academic center. Material and Methods A total of 6586 patients (3630 men and 2956 women; mean age 57.0 +- 11.9 years) who underwent contrast-enhanced CT between January and December 2008 were retrospectively studied. Of these, 829 had cardiovascular diseases (CVD), 5116 had oncologic diseases, 178 had diabetes mellitus (DM), and 1572 had chronic liver disease (CLD). The eGFR (mL/min/1.73 m2) was calculated from their serum creatinine level. Mild, moderate-a, moderate-b, and severe RI were recorded at 60 < =eGFR < 90, 45 < =eGFR < 60, 30 < =eGFR < 45 and eGFR < 30, respectively. Results Of the 6586 patients, 1.6%, 3.7%, 13.7%, and 54.2% were judged to present with severe, moderate-b, moderate-a, and mild RI, respectively. While moderate-b-to-severe RI was recorded in 133 (3.2%) of 4161 patients aged 70 years or less, it was observed in 218 (9.0%) of the 2425 patients who were 71 years or older. Among the 829 CVD patients, 9.9% manifested moderate-b-to-severe- and 73.0% mild-to-moderate-a RI. The corresponding rates were 4.4% and 68.9% for oncologic disease, 16.9% and 61.2% for DM, and 4.8% and 71.5% for CLD patients. By univariate analysis, there was a significant association between moderate-b-to-severe RI and the advanced age, CVD, DM, and non-oncologic disease. Multivariate analysis showed that the advanced age, DM, and non-oncologic disease were statistically associated with moderate-b-to-severe RI. Conclusion The incidence of RI of eGFR < 45mL/min/1.73 m2 at baseline was high in patients with advanced age, CVD and DM and

  15. Quantitative analysis of contrast enhancement of transplanted kidneys under computed tomography

    International Nuclear Information System (INIS)

    Fujita, Tamio; Asano, Haruyoshi; Yanaoka, Masanori; Moriguchi, Ryuichiro; Okishio, Norihiko

    1981-01-01

    Using Hitachi CT-3, the changes in CT numbers of the kidney were calculated in 10 normal and 12 transplanted kidneys. Two mililiters per kg of meglumine diatrizoate (Angiografin) was given intravenously in bolus fashion. Kidneys were scanned before injection, at termination of injection and correctly 10 minutes after injection. In control group, the CT numbers of the cortex, the medulla and the aorta showed rapid increase after contrast administration. Ten minutes after administration of medium, the CT numbers of the medulla remained a little higher than the cortex, though that of the aorta showed rapid decrease. In contrast to control group, in transplanted kidneys the CT numbers of the cortex and medulla showed less increase than the control group just after contrast administration. Moreover, in the recipients who have had good graft function the CT numbers of the cortex and medulla showed gradual increase, in the recipients who have had poor graft function the CT numbers showed gradual decrease 10 minutes after injection. Enhancing indices calculated from the formula: CT numbers 10 minutes after contrast enhancement CT numbers before contrast enhancement were inversely proportional to the serum creatinine. These results lead to the conclusion that the CT scans employing contrast enhancement method after kidney transplantation has the diagnostic value of graft function in addition to diagnostic usefulness for post-transplantation complications such as hematoma, urinoma or lymphocele. (author)

  16. Utility of dynamic contrast-enhanced magnetic resonance imaging for differentiating glioblastoma, primary central nervous system lymphoma and brain metastatic tumor

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Shanshan, E-mail: lushan1118@163.com [Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province (China); Gao, Qianqian, E-mail: gaoqian123011@163.com [Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province (China); Yu, Jing, E-mail: yujing0303@163.com [Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province (China); Li, Yang, E-mail: yuhao040511@163.com [Department of Pathology,The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province (China); Cao, Peng, E-mail: peng.cao@ge.com [GE healthcare, Shanghai (China); Shi, Haibin, E-mail: hbshi346@163.com [Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province (China); Hong, Xunning, E-mail: hongxunning@sina.com [Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu Province (China)

    2016-10-15

    Purpose: The study aimed to investigate the use of dynamic contrast-enhanced magnetic resonance imaging (MRI)-derived permeability parameters for the differentiation of glioblastoma multiformes (GBMs), primary central nervous system lymphomas (PCNSLs), and brain metastatic tumors (MTs). Materials and methods: Seventy-five patients with histopathologically confirmed GBMs (n = 38), PCNSLs (n = 16) and MTs (n = 21) underwent dynamic contrast-enhanced MRIs before surgery. The volume transfer constant K{sup trans}, the flux rate constant between extravascular extracellular space and plasma K{sub ep}, the extravascular extracellular volume V{sub e} and the fractional plasma volume V{sub p} were measured within the entire contrast-enhancing tumor by extended Tofts model. A one-way analysis of variance was used to compare all of the parameters among these three tumors, followed by the post-hoc test. Receiver operating characteristic curves were constructed to evaluate the diagnostic performance of the permeability parameters. Results: Mean K{sup trans} value and V{sub e} value were significantly higher in PCNSLs than in GBMs (P < 0.001 and P = 0.011) and MTs (P < 0.001 and P < 0.001). No significant difference was observed in all of the permeability parameters between GBMs and MTs. According to the receiver operating characteristic analyses, both K{sup trans} and V{sub e} had good diagnostic performance for discriminating between PCNSLs and GBMs (the area under the curve: 0.847 and 0.785, respectively), as well as between PCNSLs and MTs (the area under the curve: 0.851 and 0.884, respectively). Conclusions: The K{sup trans} and V{sub e} derived from dynamic contrast-enhanced MRI facilitate the differentiation of PCNSLs from GBMs and MTs.

  17. A contrast enhancement method for improving the segmentation of breast lesions on ultrasonography.

    Science.gov (United States)

    Flores, Wilfrido Gómez; Pereira, Wagner Coelho de Albuquerque

    2017-01-01

    This paper presents an adaptive contrast enhancement method based on sigmoidal mapping function (SACE) used for improving the computerized segmentation of breast lesions on ultrasound. First, from the original ultrasound image an intensity variation map is obtained, which is used to generate local sigmoidal mapping functions related to distinct contextual regions. Then, a bilinear interpolation scheme is used to transform every original pixel to a new gray level value. Also, four contrast enhancement techniques widely used in breast ultrasound enhancement are implemented: histogram equalization (HEQ), contrast limited adaptive histogram equalization (CLAHE), fuzzy enhancement (FEN), and sigmoid based enhancement (SEN). In addition, these contrast enhancement techniques are considered in a computerized lesion segmentation scheme based on watershed transformation. The performance comparison among techniques is assessed in terms of both the quality of contrast enhancement and the segmentation accuracy. The former is quantified by the measure, where the greater the value, the better the contrast enhancement, whereas the latter is calculated by the Jaccard index, which should tend towards unity to indicate adequate segmentation. The experiments consider a data set with 500 breast ultrasound images. The results show that SACE outperforms its counterparts, where the median values for the measure are: SACE: 139.4, SEN: 68.2, HEQ: 64.1, CLAHE: 62.8, and FEN: 7.9. Considering the segmentation performance results, the SACE method presents the largest accuracy, where the median values for the Jaccard index are: SACE: 0.81, FEN: 0.80, CLAHE: 0.79, HEQ: 77, and SEN: 0.63. The SACE method performs well due to the combination of three elements: (1) the intensity variation map reduces intensity variations that could distort the real response of the mapping function, (2) the sigmoidal mapping function enhances the gray level range where the transition between lesion and background

  18. Renal streaky artifact during contrast-enhanced abdominal and pelvic CT: Comparison of high versus low osmolality contrast media

    International Nuclear Information System (INIS)

    Kim, Dae Hong; Kim, Jong Chul; Lee, Chung Keun; Shin, Kyoung Suk

    1994-01-01

    Introduction of low osmolality contrast agent(LOCA) has allowed safer, more comfortable contrast-enhanced CT examination, but there has been significant increase in image degradation when evaluating the kidneys due to streaky artifact. The authors reviewed findings of contrast- enhanced abdominal and pelvic computed tomography(CT) to know the difference of renal streaky artifact between a high osmolality contrast agent (HOCA) and LOCA. This study included two hundred contrast-enhanced CT in 200 patients, 100 performed with HOCA(meglumine ioglicate, 150 ml) and 100 performed with LOCA (iopromide,150 ml). The severity of renal streaky artifact was compared between HOCA and LOCA groups. Of the scans performed with HOCA, 40 had no artifact, 52 had grade I artifact, 6 had grade II artifact, and 2 had grade III artifact. Of the scans preformed with LOCA, 23 had no artifact, 44 had grade I artifact, 29 had grade II artifact, and 4 had grade III artifact. There was significant difference in the degree of the streaky artifact depending upon the osmolality of the contrast media used(by χ 2 -test, P=.0001). The results of this study revealed a statistically significant increased incidence of artifacts and distortions of renal image with LOCA when compared with HOCA

  19. Iohexol for contrast enhancement of bowel in pediatric abdominal CT

    International Nuclear Information System (INIS)

    Smevik, B.; Westvik, J.

    1990-01-01

    Abdominal CT scans from 160 examinations performed on pediatric patients using iohexol 2 percent as contrast medium for bowel enhancement were evaluated retrospectively. When diluted with a beverage of the child's choice, iohexol has a neutral taste and cannot be detected, and 139 out of 142 patients drank the full amount of dilute contrast offered to them. The enhancement of bowel in the area of interest was graded as good (58%), reasonable (23%), or poor (19%). The contrast medium was prepared from leftovers from our angiocardiography studies. We conclude that the use of water-soluble contrast medium in a low concentration is a safe and cost-effective way of facilitating ingesion of sufficient amounts of the medium in oncologic pediatric patients undergoing cytotoxic and/or radiation treatment. (orig.)

  20. Contrast enhancement of the gyri in herpes simplex encephalitis

    International Nuclear Information System (INIS)

    Schumacher, K.A.; Langer, M.; Langer, R.

    1982-01-01

    A case of herpes simplex encephalitis was examined by computer tomography. Both cerebral hemispheres showed contrast enhancement of the gyri. The cause of this is considered. The increased contrast medium accumulation in the affected areas is probably due to the marked vascular proliferation which can be demonstrated anatomically, and to the rapid escape of contrast from the capillaries into the interstitial spaces. The findings of other authors, which differ somewhat, are discussed. (orig.) [de

  1. Contrast Enhancement in Poor Visibility Conditions Using Guided Filtering

    Directory of Open Access Journals (Sweden)

    D

    2013-06-01

    Full Text Available In this paper, extraction of atmospheric veil is proposed to enhance the contrast of the images captured under poor visibility conditions. The method based on guided filtering can accurately recover hidden edges, maintain structural similarity (SSIM to input image and it is effective for both color and gray level images. The proposed algorithm works without prior information about the scene and its complexity is linear function of the input image size. Experimental comparisons with state of the art algorithms demonstrate that our approach can significantly enhance the contrast and restore the visibility in fine details.

  2. Contrast-enhanced thoracic 3D-MR angiography in infants and children

    International Nuclear Information System (INIS)

    Holmqvist, C.; Larsson, E.M.; Staahlberg, F.; Laurin, S.

    2000-01-01

    To optimise breath-hold contrast-enhanced MR angiography (MRA) in infants and children with suspected congenital heart or thoracic vessel malformation. Thirty-nine children (median age 1 year) were examined, using five different ultrafast MRA sequences with a TR between 3.2 and 5.0 ms and the contrast agent meglumine gadoterate. A test injection was used to determine contrast travel time. Different parameters for contrast injection were evaluated. Signal-to-noise ratio (SNR) measurements were performed and image quality and injection timing were evaluated. MRA was successful in all patients and image quality was considered very good in 52%. Adequate SNR was achieved with no significant differences between the MR sequences. SNR decreased only 25 - 30% between subsequent scans. The mean contrast dose was 0.23 mmol/kg. The mean scan time was 12.5±3.8 s; the shorter scan times made dynamic examinations possible with high temporal resolution. Highest spatial resolution was obtained with TR 4.6/5.0 sequences. A contrast dose of 0.2 mmol/kg b.w. is recommended with an injection rate of 0.5 to 1.2 ml/s, depending on patient size and scan time. The scan delay time should equal the contrast travel time for optimal vessel enhancement. In the future, contrast-enhanced MRA may be a potential alternative to angiocardiography in infants and children

  3. Contrast-enhanced ultrasound study of primary hepatic angiosarcoma: A pitfall of non-enhancement

    International Nuclear Information System (INIS)

    Wang, Liang; Lv, Ke; Chang, Xiao-Yan; Xia, Yu; Yang, Zhi-Ying; Jiang, Yu-Xin; Dai, Qing; Tan, Li; Li, Jian-Chu

    2012-01-01

    Highlights: ► The contrast-enhanced ultrasound (CEUS) characteristics of primary hepatic angiosarcoma (PHA) in three patients were retrospectively analyzed. ► PHA appeared similar peripheral enhancement pattern in our series. ► Non-necrotic tumor tissue of PHA unexpectedly demonstrated non-enhancement on CEUS. ► It may be associated with the very low velocity of blood flow in the central region of tumors. ► This interesting finding warrants further investigations, particularly on intratumoral hemodynamics. -- Abstract: Objective: To investigate the contrast-enhanced ultrasound (CEUS) characteristics of primary hepatic angiosarcoma (PHA). Methods: The sonographic findings and CEUS images of PHA in three patients were retrospectively analyzed. Results: In our study, 3 cases of PHA (2 multiple nodules and 1 solitary mass) showed similar enhancement pattern on CEUS, characterized by remarkable central non-enhancement and peripheral irregular enhancement in the arterial and portal phase, and complete wash-out in the late phase. Furthermore, we unexpectedly found that abundant neoplastic tissues were present in the central area of non-enhancement on pathological evaluation. Based on literature review, we supposed that the unusual finding may be associated with the very low velocity of blood flow in the central region of tumors. Conclusion: CEUS could well depict PHA with some common features, which may provide valuable clues in diagnosis of this rare disease. And non-necrotic tumor tissue of PHA could also demonstrate non-enhancement on CEUS, which warrant further investigations

  4. Immunologic basis for adverse reactions to radiographic contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Stejskal, V; Nilsson, R; Grepe, A [Astra Pharmaceuticals AB, Soedertaelje (Sweden). Lab. of Safety Assessment Stockholm Univ. (Sweden). Dept. of Genetic and Cellular Toxicology Stockholm Univ. (Sweden). Wallenberglaboratoriet Danderyds Sjukhus, Danderyd (Sweden). Radiologic Clinic

    1990-11-01

    The lymphocyte transformation test (LTT) was used to elucidate whether certain side effects induced by radiographic contrast media have an immunologic etiology. Groups studied were: 8 patients who had previously experienced adverse reactions in association with urography, 6 patients who underwent urography without notable side reactions, 17 occupationally exposed nurses, and 9 unexposed controls. The lymphocytes from 2 hypersensitive patients and from 11 nurses exhibited a positive proliferative response to amidotrizoate. Five nurses who had shown a positive response, had a previous history of hypersensitivity reactions when handling contrast media, whereas the remaining 6 were free of symptoms. Amidotrizoatespecific memory cells were absent in patients who underwent urography without signs of hypersensitivity and in 7/9 of unexposed control subjects. Lymphocytes from patients sensitive to amidotrizoate cross-reacted to structurally related ionic contrast media while nonionic contrast agents did not induce proliferation of the lymphocytes. Thus, ionic radiographic contrast agents have antigenic properties in man. Irradiated mixtures of radiographic contrast media and serum proteins were, in general, not effective in inducing an LTT response. (orig.).

  5. Immunologic basis for adverse reactions to radiographic contrast media

    International Nuclear Information System (INIS)

    Stejskal, V.; Nilsson, R.; Grepe, A.; Stockholm Univ.; Stockholm Univ.; Danderyds Sjukhus, Danderyd

    1990-01-01

    The lymphocyte transformation test (LTT) was used to elucidate whether certain side effects induced by radiographic contrast media have an immunologic etiology. Groups studied were: 8 patients who had previously experienced adverse reactions in association with urography, 6 patients who underwent urography without notable side reactions, 17 occupationally exposed nurses, and 9 unexposed controls. The lymphocytes from 2 hypersensitive patients and from 11 nurses exhibited a positive proliferative response to amidotrizoate. Five nurses who had shown a positive response, had a previous history of hypersensitivity reactions when handling contrast media, whereas the remaining 6 were free of symptoms. Amidotrizoatespecific memory cells were absent in patients who underwent urography without signs of hypersensitivity and in 7/9 of unexposed control subjects. Lymphocytes from patients sensitive to amidotrizoate cross-reacted to structurally related ionic contrast media while nonionic contrast agents did not induce proliferation of the lymphocytes. Thus, ionic radiographic contrast agents have antigenic properties in man. Irradiated mixtures of radiographic contrast media and serum proteins were, in general, not effective in inducing an LTT response. (orig.)

  6. Morphological image processing for quantitative shape analysis of biomedical structures: effective contrast enhancement

    International Nuclear Information System (INIS)

    Kimori, Yoshitaka

    2013-01-01

    A contrast enhancement approach utilizing a new type of mathematical morphology called rotational morphological processing is introduced. The method is quantitatively evaluated and then applied to some medical images. Image processing methods significantly contribute to visualization of images captured by biomedical modalities (such as mammography, X-ray computed tomography, magnetic resonance imaging, and light and electron microscopy). Quantitative interpretation of the deluge of complicated biomedical images, however, poses many research challenges, one of which is to enhance structural features that are scarcely perceptible to the human eye. This study introduces a contrast enhancement approach based on a new type of mathematical morphology called rotational morphological processing. The proposed method is applied to medical images for the enhancement of structural features. The effectiveness of the method is evaluated quantitatively by the contrast improvement ratio (CIR). The CIR of the proposed method is 12.1, versus 4.7 and 0.1 for two conventional contrast enhancement methods, clearly indicating the high contrasting capability of the method

  7. An improved contrast enhancement algorithm for infrared images based on adaptive double plateaus histogram equalization

    Science.gov (United States)

    Li, Shuo; Jin, Weiqi; Li, Li; Li, Yiyang

    2018-05-01

    Infrared thermal images can reflect the thermal-radiation distribution of a particular scene. However, the contrast of the infrared images is usually low. Hence, it is generally necessary to enhance the contrast of infrared images in advance to facilitate subsequent recognition and analysis. Based on the adaptive double plateaus histogram equalization, this paper presents an improved contrast enhancement algorithm for infrared thermal images. In the proposed algorithm, the normalized coefficient of variation of the histogram, which characterizes the level of contrast enhancement, is introduced as feedback information to adjust the upper and lower plateau thresholds. The experiments on actual infrared images show that compared to the three typical contrast-enhancement algorithms, the proposed algorithm has better scene adaptability and yields better contrast-enhancement results for infrared images with more dark areas or a higher dynamic range. Hence, it has high application value in contrast enhancement, dynamic range compression, and digital detail enhancement for infrared thermal images.

  8. Contrast-enhanced ultrasonographic spoke-wheel sign in hepatic focal nodular hyperplasia

    International Nuclear Information System (INIS)

    Yen, Y.-H.; Wang, J.-H.; Lu, S.-N.; Chen, T.-Y.; Changchien, C.-S.; Chen, C.-H.; Hung, C.-H.; Lee, C.-M.

    2006-01-01

    Background: To determine the utility of contrast-enhanced ultrasonography (CEUS) in assessing hepatic tumors with central feeding arteries found by color/power Doppler ultrasonograophy (CDUS/PDUS). Methods: We prospectively studied 37 hepatic tumors (34 patients), with a mean size of 2.9 cm and each having a central feeding artery, by CDUS/PDUS. The CEUS was performed with a galactose-based microbubble contrast agent. The detection of a spoke-wheel sign was interpreted as evidence of focal nodular hyperplasia (FNH). All patients underwent tumor biopsies or surgical resection. Results: CEUS showed a central feeding artery with a spoke-wheel sign in 36 tumors, including 34 FNHs and 2 hepatocellular carcinomas. The remaining tumor was demonstrated to be FNH despite the absence of a spoke-wheel sign as detected by CEUS. The sensitivity of the spoke-wheel sign or central scar for FNH was 97.1% (34/35), 40% (14/35), 28.6% (10/35), 50% (8/16) and 0% (0/15) for CEUS, CDUS/PDUS, dynamic computed tomography (CT) or magnetic resonance imaging (MRI), hepatic angiography and liver scintigraphy, respectively. The two hepatocellular carcinomas showed scirrhous changes histologically. Conclusions: CEUS is more sensitive than CDUS/PDUS, dynamic CT, MRI, hepatic angiography and liver scintigraphy in the detection of the spoke-wheel sign or central scar in FNH. Scirrhous hepatocellular carcinoma should be included in the differential diagnosis for liver tumors with spoke-wheel sign detected by CEUS

  9. Contrast-enhanced ultrasonographic spoke-wheel sign in hepatic focal nodular hyperplasia

    Energy Technology Data Exchange (ETDEWEB)

    Yen, Y.-H. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China); Wang, J.-H. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China)]. E-mail: wajing@adm.cgmh.org.tw; Lu, S.-N. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China); Chen, T.-Y. [Department of Radiology, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, College of Medicine, Chang Gung University, Taoyuan, Taiwan (China); Changchien, C.-S. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China); Chen, C.-H. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China); Hung, C.-H. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China); Lee, C.-M. [Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, 123 Ta-Pei Road, Kaohsiung 833, Taiwan (China)

    2006-12-15

    Background: To determine the utility of contrast-enhanced ultrasonography (CEUS) in assessing hepatic tumors with central feeding arteries found by color/power Doppler ultrasonograophy (CDUS/PDUS). Methods: We prospectively studied 37 hepatic tumors (34 patients), with a mean size of 2.9 cm and each having a central feeding artery, by CDUS/PDUS. The CEUS was performed with a galactose-based microbubble contrast agent. The detection of a spoke-wheel sign was interpreted as evidence of focal nodular hyperplasia (FNH). All patients underwent tumor biopsies or surgical resection. Results: CEUS showed a central feeding artery with a spoke-wheel sign in 36 tumors, including 34 FNHs and 2 hepatocellular carcinomas. The remaining tumor was demonstrated to be FNH despite the absence of a spoke-wheel sign as detected by CEUS. The sensitivity of the spoke-wheel sign or central scar for FNH was 97.1% (34/35), 40% (14/35), 28.6% (10/35), 50% (8/16) and 0% (0/15) for CEUS, CDUS/PDUS, dynamic computed tomography (CT) or magnetic resonance imaging (MRI), hepatic angiography and liver scintigraphy, respectively. The two hepatocellular carcinomas showed scirrhous changes histologically. Conclusions: CEUS is more sensitive than CDUS/PDUS, dynamic CT, MRI, hepatic angiography and liver scintigraphy in the detection of the spoke-wheel sign or central scar in FNH. Scirrhous hepatocellular carcinoma should be included in the differential diagnosis for liver tumors with spoke-wheel sign detected by CEUS.

  10. Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    Science.gov (United States)

    Natsume, Takahiro; Ishida, Masaki; Kitagawa, Kakuya; Nagata, Motonori; Sakuma, Hajime; Ichihara, Takashi

    2015-11-01

    The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models requires faithful recording of contrast content in the blood and myocardium. Typically, the arterial input function (AIF) is obtained by setting a region of interest in the left ventricular cavity. However, there is a small delay between the AIF and the myocardial curves, and such time discrepancies can lead to errors in flow estimation using Patlak plot analysis. In this study, the time discrepancies between the arterial TSI curve and the myocardial tissue TSI curve were estimated based on the compartment model. In the early phase after the arrival of the contrast agent in the myocardium, the relationship between rate constant K1 and the concentrations of Gd-DTPA contrast agent in the myocardium and arterial blood (LV blood) can be described by the equation K1={dCmyo(tpeak)/dt}/Ca(tpeak), where Cmyo(t) and Ca(t) are the relative concentrations of Gd-DTPA contrast agent in the myocardium and in the LV blood, respectively, and tpeak is the time corresponding to the peak of Ca(t). In the ideal case, the time corresponding to the maximum upslope of Cmyo(t), tmax, is equal to tpeak. In practice, however, there is a small difference in the arrival times of the contrast agent into the LV and into the myocardium. This difference was estimated to correspond to the difference between tpeak and tmax. The magnitudes of such time discrepancies and the effectiveness of the correction for these time discrepancies were measured in 18 subjects who underwent myocardial perfusion MRI under rest and stress conditions. The effects of the time discrepancies could be corrected effectively in the myocardial perfusion estimates. Copyright © 2015 Elsevier Inc. All rights

  11. MR imaging of spine and spinal canal neoplasms: value of Gd-DTPA contrast enhancement

    International Nuclear Information System (INIS)

    Paprzycki, W.; Gradzki, J.; Sosnowski, P.; Stajgis, M.

    1994-01-01

    Value of Gadolinium-DTPA contrast enhancement in diagnosis of neoplastic diseases of spinal canal was estimated on the basis of retrospective analysis of MR examinations performed in 75 patients. The analyzed material consisted of 15 cases of intramedullary tumors (group 1.), 38 of subdural extramedullary (group 2.) and 22 extradural ones (group 3.). Contrast enhanced MR contributed significant information to the final diagnosis in all groups. The utmost significance of Gd-DTPA contrast enhancement was ascertained in group 1. Authors conclude that contrast enhancement with Gd-DTPA is indispensable in all these cases of spinal canal neoplasms, where non-contrast MR did not reveal pathologic changes in optimal manner. (author)

  12. Contrast-enhanced breast MRI: factors affecting sensitivity and specificity

    Energy Technology Data Exchange (ETDEWEB)

    Piccoli, C.W. [Department of Radiology, Jefferson Medical College, Thomas Jefferson University Hospital, 132 South 10th Street, 7th floor, Philadelphia, PA 19107-5244 (United States)

    1997-12-31

    Contrast-enhanced MRI (CE-MRI) of the breast has been investigated for over 10 years. The reports of sensitivity for cancer detection have generally been greater than 90 %. However, estimates of specificity have varied greatly. Differing results are due to differences in study populations, technical methods and criteria for interpretation. Early and marked signal rise, detected using dynamic imaging technique following contrast administration, is the MRI hallmark of cancer. However, some malignant lesions may enhance slowly or minimally, and a variety of benign lesions may enhance rapidly with marked signal intensity. High resolution techniques generally requiring longer acquisition times are more likely to depict the slowly enhancing malignancies at the cost of a decrease in specificity due to lack of temporal resolution. This disadvantage may be offset by the improved visualization of lesion morphology with high resolution images. This report reviews the methods and results of the leading investigators of breast MRI. (orig.) With 3 figs., 70 refs.

  13. Contrast-enhanced breast MRI: factors affecting sensitivity and specificity

    International Nuclear Information System (INIS)

    Piccoli, C.W.

    1997-01-01

    Contrast-enhanced MRI (CE-MRI) of the breast has been investigated for over 10 years. The reports of sensitivity for cancer detection have generally been greater than 90 %. However, estimates of specificity have varied greatly. Differing results are due to differences in study populations, technical methods and criteria for interpretation. Early and marked signal rise, detected using dynamic imaging technique following contrast administration, is the MRI hallmark of cancer. However, some malignant lesions may enhance slowly or minimally, and a variety of benign lesions may enhance rapidly with marked signal intensity. High resolution techniques generally requiring longer acquisition times are more likely to depict the slowly enhancing malignancies at the cost of a decrease in specificity due to lack of temporal resolution. This disadvantage may be offset by the improved visualization of lesion morphology with high resolution images. This report reviews the methods and results of the leading investigators of breast MRI. (orig.)

  14. T2 values of femoral cartilage of the knee joint: Comparison between pre-contrast and post-contrast images

    International Nuclear Information System (INIS)

    Yoon, Hyun Jung; Yoon, Young Cheol; Choe, Bong Keun

    2014-01-01

    To retrospectively evaluate the relationship between T2 values of pre- and post-contrast magnetic resonance (MR) images of femoral cartilage in patients with varying degrees of osteoarthritis. A total of 19 patients underwent delayed gadolinium-enhanced MRI of cartilage. Six regions of interest for T2 value measurement were obtained from pre- and post-contrast T2-weighted, sagittal, multi-slice, multi-echo, source images in each subject. Regions with modified Noyes classification grade 2B and 3 were excluded. Comparison of T2 values between pre- and post-contrast images and T2 values among regions with the grade 0, 1 and 2A groups were statistically analyzed. Of a total of 114 regions, 79 regions showing grade 0 (n = 46), 1 (n = 18), or 2A (n = 15) were analyzed. The overall and individual T2 values of post-contrast images were significantly lower than those of pre-contrast images (overall, 35.3 ± 9.2 [mean ± SD] vs. 29.9 ± 8.2, p < 0.01; range of individual, 28.9-37.6 vs. 27.1-36.4, p < 0.01). Pearson correlation coefficients showed a strong positive correlation between pre- and post-contrast images (rho-Pearson = 0.712-0.905). T2 values of pre- and post-contrast images of the grade 0 group were significantly lower than those of the grade 1/2A group (pre T2, p = 0.003; post T2, p = 0.006). T2 values of the femoral cartilage of the knee joint are significantly lower on post-contrast images than on pre-contrast images. Furthermore, these T2 values have a strong positive correlation between pre- and post-contrast images.

  15. T2 values of femoral cartilage of the knee joint: Comparison between pre-contrast and post-contrast images

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hyun Jung; Yoon, Young Cheol [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Choe, Bong Keun [Department of Preventive Medicine, Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    2014-02-15

    To retrospectively evaluate the relationship between T2 values of pre- and post-contrast magnetic resonance (MR) images of femoral cartilage in patients with varying degrees of osteoarthritis. A total of 19 patients underwent delayed gadolinium-enhanced MRI of cartilage. Six regions of interest for T2 value measurement were obtained from pre- and post-contrast T2-weighted, sagittal, multi-slice, multi-echo, source images in each subject. Regions with modified Noyes classification grade 2B and 3 were excluded. Comparison of T2 values between pre- and post-contrast images and T2 values among regions with the grade 0, 1 and 2A groups were statistically analyzed. Of a total of 114 regions, 79 regions showing grade 0 (n = 46), 1 (n = 18), or 2A (n = 15) were analyzed. The overall and individual T2 values of post-contrast images were significantly lower than those of pre-contrast images (overall, 35.3 ± 9.2 [mean ± SD] vs. 29.9 ± 8.2, p < 0.01; range of individual, 28.9-37.6 vs. 27.1-36.4, p < 0.01). Pearson correlation coefficients showed a strong positive correlation between pre- and post-contrast images (rho-Pearson = 0.712-0.905). T2 values of pre- and post-contrast images of the grade 0 group were significantly lower than those of the grade 1/2A group (pre T2, p = 0.003; post T2, p = 0.006). T2 values of the femoral cartilage of the knee joint are significantly lower on post-contrast images than on pre-contrast images. Furthermore, these T2 values have a strong positive correlation between pre- and post-contrast images.

  16. Dynamic contrast-enhanced magnetic resonance imaging can assess vascularity within fracture non-unions and predicts good outcome

    International Nuclear Information System (INIS)

    Schoierer, Oliver; Bender, Daniel; Schmidmaier, Gerhard; Bloess, Konstantin; Kauczor, Hans-Ulrich; Weber, Marc-Andre; Burkholder, Iris

    2014-01-01

    To prospectively evaluate whether dynamic contrast-enhanced (DCE) MRI can assess vascularity within non-unions and predicts clinical outcome in combination with the clinical Non-Union Scoring System (NUSS). Fifty-eight patients with non-unions of extremities on CT underwent 3-T DCE MRI. Signal intensity curves obtained from a region-of-interest analysis were subdivided into those with more intense contrast agent uptake within the non-union than in adjacent muscle (vascularised non-union) and those with similar or less contrast uptake. The pharmacokinetic parameters of the Tofts model K trans , K ep , iAUC and V e were correlated with union at CT 1 year later (n = 49). Despite inserted osteosynthetic material, DCE parameters could be evaluated in 57 fractures. The sensitivity/specificity of vascularised non-unions as an indicator of good outcome was 83.9 %/50.0 % compared to 96.8 %/33.3 % using NUSS (n = 49). Logistic regression revealed a significant impact of NUSS on outcome (P = 0.04, odds ratio = 0.93). At first examination, median iAUC (initial area under the enhancement curve) for the ratio non-union/muscle was 10.28 in patients with good outcome compared with 3.77 in non-responders (P = 0.023). K trans , K ep and V e within the non-union were not significantly different initially (n = 57) or 1 year later (n = 19). DCE MRI can assess vascularity in fracture non-unions. A vascularised non-union correlates with good outcome. (orig.)

  17. Contrast enhancement of the cochlear aqueduct in MR imaging: its frequency and clinical significance

    International Nuclear Information System (INIS)

    Nakamura, T.; Naganawa, S.; Fukatsu, H.; Sakurai, Y.; Ishigaki, T.; Aoki, I.; Ninomiya, A.; Nakashima, T.

    2003-01-01

    There have been no previous reports on contrast enhancement of the cochlear aqueduct in magnetic resonance imaging. The purpose of the present study was to evaluate the frequency and significance of this finding. Thirty-one patients (15 men and 16 women; age range 18-81 years) with otologic symptoms (sudden sensorineural hearing loss, vertigo, or tinnitus) were examined using contrast-enhanced imaging on a 1.5-T MR scanner. The normal ear served as the control. Two radiologists evaluated contrast enhancement in the area of the cochlear aqueduct. Forty-eight of 62 ears (77.4%) showed contrast enhancement of the cochlear aqueduct, but no significant differences in the frequency of contrast enhancement were observed between patients with and patients without vertigo, tinnitus, sensorineural hearing loss, cerebellopontine angle tumors, or a high-riding jugular bulb. In addition, no gender- or age-related differences were noted. Contrast enhancement of the cochlear aqueduct was frequently observed, but the frequency of enhancement in symptomatic ears was not significantly higher than in control ears. The results of this study may prove helpful in avoiding unnecessary examinations and potential diagnostic confusion. (orig.)

  18. Contrast enhancement of the cochlear aqueduct in MR imaging: its frequency and clinical significance

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, T; Naganawa, S; Fukatsu, H; Sakurai, Y; Ishigaki, T [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, 466-8550, Shouwa-ku, Nagoya (Japan); Aoki, I; Ninomiya, A [Medical Systems Company, Toshiba Corporation, Nasu Operations, Otawara-shi, Tochigi (Japan); Nakashima, T [Department of Otorhinolaryngology, Nagoya University School of Medicine, Shouwa-ku, Nagoya (Japan)

    2003-09-01

    There have been no previous reports on contrast enhancement of the cochlear aqueduct in magnetic resonance imaging. The purpose of the present study was to evaluate the frequency and significance of this finding. Thirty-one patients (15 men and 16 women; age range 18-81 years) with otologic symptoms (sudden sensorineural hearing loss, vertigo, or tinnitus) were examined using contrast-enhanced imaging on a 1.5-T MR scanner. The normal ear served as the control. Two radiologists evaluated contrast enhancement in the area of the cochlear aqueduct. Forty-eight of 62 ears (77.4%) showed contrast enhancement of the cochlear aqueduct, but no significant differences in the frequency of contrast enhancement were observed between patients with and patients without vertigo, tinnitus, sensorineural hearing loss, cerebellopontine angle tumors, or a high-riding jugular bulb. In addition, no gender- or age-related differences were noted. Contrast enhancement of the cochlear aqueduct was frequently observed, but the frequency of enhancement in symptomatic ears was not significantly higher than in control ears. The results of this study may prove helpful in avoiding unnecessary examinations and potential diagnostic confusion. (orig.)

  19. Meta-analysis: Serum creatinine changes following contrast enhanced CT imaging

    International Nuclear Information System (INIS)

    Kooiman, Judith; Pasha, Sharif M.; Zondag, Wendy; Sijpkens, Yvo W.J.; Molen, Aart J. van der; Huisman, Menno V.; Dekkers, Olaf M.

    2012-01-01

    Purpose: Contrast induced nephropathy (CIN) is defined as a decrease in renal function following administration of contrast media. The aim of this meta-analysis was to asses the overall risk of CIN, chronic loss of kidney function and the need for renal replacement therapy (RRT) after intravenous contrast enhanced CT-scan. Secondly, we aimed to identify subgroups at increased risk for CIN. Materials and methods: A literature search in Pubmed, Medline, Embase and Cochrane databases was performed. Data extraction was carried out independently by two reviewers. Meta-analysis and meta-regression were performed using an exact likelihood approach. Results: Forty studies evaluating the incidence of CIN after CT were included. The pooled incidence of CIN was 6.4% (95% CI 5.0–8.1). The risk of RRT after CIN was low, 0.06% (95% CI 0.01–0.4). The decline in renal function persisted in 1.1% of patients (95% CI 0.6–2.1%). Patients with chronic kidney disease (odds ratio 2.26, p < 0.001) or diabetes mellitus (odds ratio 3.10, p < 0.001) were at increased risk for the development of CIN. Conclusion: CIN occurred in 6% of patients after contrast enhanced CT. In 1% of all patients undergoing contrast enhanced CT the decline in renal function persisted

  20. Meta-analysis: Serum creatinine changes following contrast enhanced CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kooiman, Judith, E-mail: j.kooiman@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Pasha, Sharif M., E-mail: s.m.pasha@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Zondag, Wendy, E-mail: w.zondag@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Sijpkens, Yvo W.J., E-mail: ysijpens@bronovo.nl [Department of Nephrology, Bronovo Hospital, The Hague (Netherlands); Molen, Aart J. van der, E-mail: molen@lumc.nl [Department of Radiology, LUMC, Leiden (Netherlands); Huisman, Menno V., E-mail: m.v.huisman@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Dekkers, Olaf M., E-mail: o.m.dekkers@lumc.nl [Department of Clinical Epidemiology and Department of Endocrinology, LUMC, Leiden (Netherlands)

    2012-10-15

    Purpose: Contrast induced nephropathy (CIN) is defined as a decrease in renal function following administration of contrast media. The aim of this meta-analysis was to asses the overall risk of CIN, chronic loss of kidney function and the need for renal replacement therapy (RRT) after intravenous contrast enhanced CT-scan. Secondly, we aimed to identify subgroups at increased risk for CIN. Materials and methods: A literature search in Pubmed, Medline, Embase and Cochrane databases was performed. Data extraction was carried out independently by two reviewers. Meta-analysis and meta-regression were performed using an exact likelihood approach. Results: Forty studies evaluating the incidence of CIN after CT were included. The pooled incidence of CIN was 6.4% (95% CI 5.0–8.1). The risk of RRT after CIN was low, 0.06% (95% CI 0.01–0.4). The decline in renal function persisted in 1.1% of patients (95% CI 0.6–2.1%). Patients with chronic kidney disease (odds ratio 2.26, p < 0.001) or diabetes mellitus (odds ratio 3.10, p < 0.001) were at increased risk for the development of CIN. Conclusion: CIN occurred in 6% of patients after contrast enhanced CT. In 1% of all patients undergoing contrast enhanced CT the decline in renal function persisted.

  1. Value of contrast-enhanced MRI of breast after silicone implant

    International Nuclear Information System (INIS)

    Heinig, A.; Heywang-Koebrunner, S.H.; Viehweg, P.; Spielmann, R.P.; Lampe, D.; Buchmann, J.

    1997-01-01

    Early recognition of recurrence and work-up of clinically indeterminate lesions may be impaired after reconstruction with silicone implants due to superimposition of the implant or to scarring. This study was undertaken to evaluate the use of contrast-enhanced MRI in patients with silicone implant after breast cancer. Contrast-enhanded MRI was offered to 169 patients. Comparative two- to three-view mammography was also performed in 169 patients, as well as comparative sonography in 144 patients. Conventional imaging and clinical examination detected only 8/13 recurrences, whereas 12/13 were detected by MRI. One recurrence had been visible as a strongly enhancing 2-mm dot in a previous examination (2 years before), but was not called. It was therefore counted as false negative. In addition, multicentricity was detected by MRI alone in two of three cases. MRI correctly diagnosed scar tissue in all cases with indeterminate findings. However, due to false-positive calls caused by enhancing granulomas specificity could not be improved. Contrast-enhanded MRI allowed decisive additional information in our study group and improved the sensitivity significantly (concerning all diagnoses). Contrast-enhanded MRI allowed decisive additional information in our study group and improved the sensitivity significantly (concerning all diagnoses). Contrast-enhanded MRI is recommended in patients with diagnostic problems or high risk of recurrence after silicone implants. (orig.) [de

  2. Contrast-enhanced ultrasound in diagnosis and characterization of focal hepatic lesions.

    Science.gov (United States)

    Molins, Inés Gómez; Font, Juan Manuel Fernández; Alvaro, Juan Carrero; Navarro, Jose Luís Lledó; Gil, Marta Fernández; Rodríguez, Conrado M Fernández

    2010-12-28

    The extensive use of imaging techniques in differential diagnosis of abdominal conditions and screening of hepatocellular carcinoma in patients with chronic hepatic diseases, has led to an important increase in identification of focal liver lesions. The development of contrast-enhanced ultrasound (CEUS) opens a new window in the diagnosis and follow-up of these lesions. This technique offers obvious advantages over the computed tomography and magnetic resonance, without a decrease in its sensitivity and specificity. The new second generation contrast agents, due to their intravascular distribution, allow a continuous evaluation of the enhancement pattern, which is crucial in characterization of liver lesions. The dual blood supply in the liver shows three different phases, namely arterial, portal and late phases. The enhancement during portal and late phases can give important information about the lesion's behavior. Each liver lesion has a different enhancement pattern that makes possible an accurate approach to their diagnosis. The role of emerging techniques as a contrast-enhanced three-dimensional US is also discussed. In this article, the advantages, indications and technique employed during CEUS and the different enhancement patterns of most benign and malignant focal liver lesions are discussed.

  3. Magnetic iron oxide for contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Fahlvik, A.K.

    1991-05-01

    The main objective of this experimental work has been to study the biological fate and the contrast enhancing potential of a model preparation of magnetic iron oxide (MSM) after intravenous injection to rodents. This was achieved by: Studying in vitro contrast efficacy of various magnetic iron oxide preparations by relaxation analysis. Studying in vivo contrast efficacy of MSM by relaxation analysis and NMR imaging. Studying the biodistribution and bioelimination of MSM in independent experiments using relaxation analysis, radioactivity studies and histological techniques. Studying interactions of MSM with target cells and target organelles using ex vivo techniques. Based on the presented experimental study, the MSM model preparation of magnetic iron oxide seems to fulfill basic requirements of NMR contrast agents: efficient proton relaxation, specific in vivo distribution, and biological tolerance. 177 refs., 5 figs., 2 tabs

  4. Contrast enhancement by differently sized paramagnetic MRI contrast agents in mice with two phenotypes of atherosclerotic plaque

    NARCIS (Netherlands)

    van Bochove, Glenda S.; Paulis, Leonie E. M.; Segers, Dolf; Mulder, Willem J. M.; Krams, Rob; Nicolay, Klaas; Strijkers, Gustav J.

    2011-01-01

    Interest in the use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of three differently sized gadolinium-based contrast agents to permeate different mouse plaque phenotypes was evaluated with MRI. A

  5. Dynamic contrast-enhanced MRI in patients with luminal Crohn's disease

    NARCIS (Netherlands)

    Ziech, M. L. W.; Lavini, C.; Caan, M. W. A.; Nio, C. Y.; Stokkers, P. C. F.; Bipat, S.; Ponsioen, C. Y.; Nederveen, A. J.; Stoker, J.

    2012-01-01

    Objectives: To prospectively assess dynamic contrast-enhanced (DCE-)MRI as compared to conventional sequences in patients with luminal Crohn's disease. Methods: Patients with Crohn's disease undergoing MRI and ileocolonoscopy within 1 month had DCE-MRI (3T) during intravenous contrast injection of

  6. Contrast enhancement technique in brain 3D-CTA studies. Optimizing the amount of contrast medium according to scan time based on TDC

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi

    2008-01-01

    In three-dimensional CT angiography (3D-CTA), good reproducibility can be obtained by maintaining the maximum CT numbers (HU) at a specified level. However, the correlation between the scan time and the injection time showed that the maximum CT numbers increased and varied due to the additional contrast enhancement effect from recirculation of the injected contrast medium for longer injection times when the dose of iodinated contrast medium per unit time (mgI/s) was maintained at a specified level based on the time-density curve (TDC) of the phantom. The amount of contrast medium employed at our hospital has been optimized based on an iodinated contrast medium dose per unit time providing a contrast enhancement effect of 300 HU in the middle cerebral artery. Using this standard, a TDC phantom was employed to obtain an iodinated contrast medium dose per unit time, permitting equivalent maximum CT values (used as standard values) to be obtained by changing the injection time. A contrast-enhancement technique that accounts for the variation in the scan time was evaluated. Strong correlations were observed between the scan time and the injection time (R 2 =0.969) and between the injection time and the dose of iodinated contrast medium per unit body weight (R 2 =0.994). We conclude that adjusting the dose of iodinated contrast medium per unit body weight per unit time according to the scan time permits optimization of the contrast-enhancement technique. (author)

  7. The role of contrast-enhanced ultrasound in risk assessment of carotid atheroma

    Directory of Open Access Journals (Sweden)

    Silviu Stanciu

    2016-07-01

    Full Text Available Background and objective: Contrast-enhanced ultrasound, used to assess atherosclerotic carotid plaques, improves visualization of vessel wall irregularities and depicts intraplaque neovascularization. This article illustrates the use of contrast-enhanced ultrasound in the risk assessment of carotid atherosclerotic lesions, especially in challenging plaques evaluation. Materials and methods: For 23 patients with difficult duplex ultrasound examination due to carotid tortuosity or calcifications we assessed plaque morphology (contour, echogenicity and stenosis degree using contrast substance (Sonovue, Braco with dedicated vascular low mechanical index CPC software. Conclusion: Contrast-enhanced ultrasound is a new, noninvasive, and safe procedure for imaging carotid atherosclerotic lesions. It is a valuable tool for evaluating the vulnerable plaque at risk for rupture and for the diagnostic of the development and severity of systemic atherosclerotic disease

  8. Technical aspects of contrast-enhanced magnetic resonance imaging of the breast: literature review

    International Nuclear Information System (INIS)

    Leopoldino, Denise de Deus; Gracio, Tatiana Schiller; D'Ippolito, Giuseppe; Bezerra, Alexandre Sergio de Araujo; Gracio, Tatiana Schiller

    2005-01-01

    With the advances in surface coil technology and the development of new imaging protocols in addition to the increase of the use of contrast agents, contrast enhanced magnetic resonance imaging (MRI) has emerged as a promising modality for detection, diagnosis and staging of breast cancer. Despite these advances, there are some unresolved issues, including no defined standard technique for contrast-enhanced breast MRI and no standard criteria of interpretation for the evaluation of such studies. In this article, we review the literature and discuss the general requirements and recommendations for contrast agent-enhanced breast MRI, including image interpretation criteria, MR equipment, dedicated radiofrequency coils, use of paramagnetic contrast agents, fat-suppression techniques, planes of acquisition, pulse sequence specifications and artifact sources. (author)

  9. High contrast enhancement aspect of dynamic computed tomography with arterial infusion - DCT-AI

    International Nuclear Information System (INIS)

    Kato, Seishi; Iwasaki, Naoya; Matsumura, Yoshimitsu; Kuramae, Shigeru; Mishiro, Tadashi

    1983-01-01

    Dynamic computed tomography was performed on 112 cases possibly having hepatic tumors with intraarterial infusion of undiluted contrast into a selectively placed catheter following angiographies. Our dynamic program could evaluate not only early phase of enhancement but also late phase up to 120 sec. Reconstructed views from early scans and magnified views were very useful to evaluate minute sequential changes. Hepatic masses less than 5 cm in size were found in thirty-one cases. Patterns of tumor enhancement and time-density curves have been analysed to correlate them with histology. Four types of tumor enhancement were noted: (1) homogeneous (2) patchy (3) mottled (4) ringed. Characteristic changes were observed in hepatocellular carcinoma - HCC - (mostly mottled) and haemangioma (mostly patchy). The former was divided in two groups reflecting the cellular maturity. The metastatic tumor could be enhanced in a ringed form with dendritic pattern of supplying vascularities in some cases. To support the use of undiluted contrast and to investigate the diagnostic efficacy of high contrast enhancement, experiments were performed by taking transaxial views of an acrylic phantom immersed in different concentrations of contrast. Analysis of CT images taken at different HU values ranging from 0 to 450 demonstrated that the higher the concentration of contrast, the better the spatial resolution was. Also larger magnification could be expected by using higher concentration of contrast. Although our Dynamic Computed Tomography with Arterial Infusion of Contrast still has drawbacks and limited indications, we advocate it as a better way of enhancement to detect and evaluate the hepatic masses, which sometimes elude the examiner's grasp with conventional way of enhancement. (author)

  10. Apparition of iodinated contrast agents in twin neonatal gastrointestinal tracts after maternal contrast-enhanced computed tomography

    International Nuclear Information System (INIS)

    Kato, Hiroki; Kanematsu, Masayuki; Kato, Zenichiro; Kondo, Naomi; Orii, Kenji E.; Morimoto, Masahiro

    2011-01-01

    We describe a case of the appearance of iodinated contrast agents in the same locations of twins' neonatal gastrointestinal tracts 1 day after maternal contrast-enhanced computed tomography (CT). The CT examination had been performed on the expectant mother for suspected deep venous thrombosis on the day previous to the twin delivery. At 23 h after the CT examination and after cesarean section, iodinated contrast agents appeared in the same place in the twins' neonatal gastrointestinal tracts, mainly in the ascending colon, on plain abdominal radiographs. Radiologists, obstetricians, and pediatricians should understand the mechanism of appearance of iodinated contrast agents in fetal gastrointestinal tracts when the expectant mother had been given iodinated contrast agents intravenously shortly before delivery. (author)

  11. A review on brightness preserving contrast enhancement methods for digital image

    Science.gov (United States)

    Rahman, Md Arifur; Liu, Shilong; Li, Ruowei; Wu, Hongkun; Liu, San Chi; Jahan, Mahmuda Rawnak; Kwok, Ngaiming

    2018-04-01

    Image enhancement is an imperative step for many vision based applications. For image contrast enhancement, popular methods adopt the principle of spreading the captured intensities throughout the allowed dynamic range according to predefined distributions. However, these algorithms take little or no consideration into account of maintaining the mean brightness of the original scene, which is of paramount importance to carry the true scene illumination characteristics to the viewer. Though there have been significant amount of reviews on contrast enhancement methods published, updated review on overall brightness preserving image enhancement methods is still scarce. In this paper, a detailed survey is performed on those particular methods that specifically aims to maintain the overall scene illumination characteristics while enhancing the digital image.

  12. High-resolution blood-pool-contrast-enhanced MR angiography in glioblastoma: tumor-associated neovascularization as a biomarker for patient survival. A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Puig, Josep; Blasco, Gerard; Remollo, Sebastian; Hernandez, David; Pedraza, Salvador [Hospital Universitari Dr Josep Trueta, Research Unit of Diagnostic Imaging Institute (IDI), Department of Radiology [Girona Biomedical Research Institute] IDIBGI, Girona (Spain); Daunis-i-Estadella, Josep; Mateu, Gloria [University of Girona, Department of Computer Science, Applied Mathematics and Statistics, Girona (Spain); Alberich-Bayarri, Angel [La Fe Polytechnics and University Hospital, Biomedical Imaging Research Group (GIBI230), La Fe Health Research Institute, Valencia (Spain); Essig, Marco [University of Manitoba, Department of Radiology, Winnipeg (Canada); Jain, Rajan [NYU School of Medicine, Division of Neuroradiology, Department of Radiology, New York, NY (United States); Puigdemont, Montserrat [Hospital Universitari Dr Josep Trueta, Catalan Institute of Oncology (ICO), Hospital Cancer Registry, Girona (Spain); Sanchez-Gonzalez, Javier [Philips Healthcare Iberica, Madrid (Spain); Wintermark, Max [Stanford University, Department of Radiology, Neuroradiology Division, Palo Alto, CA (United States)

    2016-01-15

    The objective of the study was to determine whether tumor-associated neovascularization on high-resolution gadofosveset-enhanced magnetic resonance angiography (MRA) is a useful biomarker for predicting survival in patients with newly diagnosed glioblastomas. Before treatment, 35 patients (25 men; mean age, 64 ± 14 years) with glioblastoma underwent MRI including first-pass dynamic susceptibility contrast (DSC) perfusion and post-contrast T1WI sequences with gadobutrol (0.1 mmol/kg) and, 48 h later, high-resolution MRA with gadofosveset (0.03 mmol/kg). Volumes of interest for contrast-enhancing lesion (CEL), non-CEL, and contralateral normal-appearing white matter were obtained, and DSC perfusion and DWI parameters were evaluated. Prognostic factors were assessed by Kaplan-Meier survival and Cox proportional hazards model. Eighteen (51.42 %) glioblastomas were hypervascular on high-resolution MRA. Hypervascular glioblastomas were associated with higher CEL volume and lower Karnofsky score. Median survival rates for patients with hypovascular and hypervascular glioblastomas treated with surgery, radiotherapy, and chemotherapy were 15 and 9.75 months, respectively (P < 0.001). Tumor-associated neovascularization was the best predictor of survival at 5.25 months (AUC = 0.794, 81.2 % sensitivity, 77.8 % specificity, 76.5 % positive predictive value, 82.4 % negative predictive value) and yielded the highest hazard ratio (P < 0.001). Tumor-associated neovascularization detected on high-resolution blood-pool-contrast-enhanced MRA of newly diagnosed glioblastoma seems to be a useful biomarker that correlates with worse survival. (orig.)

  13. B-mode and contrast-enhanced sonographic assessment of accessory spleen in the dog.

    Science.gov (United States)

    Rossi, Federica; Rabba, Silvia; Vignoli, Massimo; Haers, Hendrik; Terragni, Rossella; Saunders, Jimmy H

    2010-01-01

    Four dogs with an accessory spleen are described. The accessory spleens appeared as a round-to-triangular structure located in the perisplenic area. They were homogeneous and isoechoic with the adjacent spleen. Contrast-enhanced ultrasound was performed using a second generation microbubble contrast medium (sulfur hexafluoride). The type and timing of enhancement of the accessory spleen was similar to that of the parent spleen. Contrast-enhanced ultrasound is a noninvasive modality useful in distinguishing an accessory spleen from a mass of another origin.

  14. Morphological rational multi-scale algorithm for color contrast enhancement

    Science.gov (United States)

    Peregrina-Barreto, Hayde; Terol-Villalobos, Iván R.

    2010-01-01

    Contrast enhancement main goal consists on improving the image visual appearance but also it is used for providing a transformed image in order to segment it. In mathematical morphology several works have been derived from the framework theory for contrast enhancement proposed by Meyer and Serra. However, when working with images with a wide range of scene brightness, as for example when strong highlights and deep shadows appear in the same image, the proposed morphological methods do not allow the enhancement. In this work, a rational multi-scale method, which uses a class of morphological connected filters called filters by reconstruction, is proposed. Granulometry is used by finding the more accurate scales for filters and with the aim of avoiding the use of other little significant scales. The CIE-u'v'Y' space was used to introduce our results since it takes into account the Weber's Law and by avoiding the creation of new colors it permits to modify the luminance values without affecting the hue. The luminance component ('Y) is enhanced separately using the proposed method, next it is used for enhancing the chromatic components (u', v') by means of the center of gravity law of color mixing.

  15. Diagnostic value of dynamic contrast-enhanced MRI for submucosal palatal tumors

    International Nuclear Information System (INIS)

    Matsuzaki, Hidenobu; Yanagi, Yoshinobu; Hara, Marina; Katase, Naoki; Hisatomi, Miki; Unetsubo, Teruhisa; Konouchi, Hironobu; Takenobu, Toshihiko

    2012-01-01

    Objectives: To evaluate the diagnostic value of dynamic contrast-enhanced MRI (DCE-MRI) for differentiating between benign and malignant tumors in the palate. Materials and methods: 26 patients with submucosal palatal tumors were preoperatively examined using DCE-MRI. Their maximum contrast index (CImax), time of CImax (Tmax), and washout ratios (WR300 and WR600) were determined from contrast index curves. The submucosal palatal tumors were divided into two groups according to their Tmax values: the early enhancement group (Tmax 2 = 0.92, P < 0.001). Conclusions: Tmax is a useful parameter for distinguishing between benign and malignant submucosal palatal tumors.

  16. A multi-slice gradient sequence for contrast enhanced MR diagnosis of intracranial tumours

    International Nuclear Information System (INIS)

    Schoerner, W.; Sander, B.; Kornmesser, W.; Laniado, M.; Nakamura, T.; Felix, R.

    1988-01-01

    A multi-slice gradient echo sequence (FLASH) was compared with a conventional spin-echo (SE) technique with regard to its value for contrast enhanced MR diagnosis. In 28 patients with cerebral tumours, SE images (SE 400/30; four images/3.4 minutes) and FLASH images (FLASH 315/14; 15 images/1.4 minutes) were obtained before and after gadolinium DTPA. After gadolinium-DTPA results were comparable for both techniques with respect to contrast enhancement, tumor contrast and delineation. Because of the higher efficiency of the FLASH 315/14 technique, this sequence is the method of choice for contrast enhanced cerebral MR imaging. (orig.) [de

  17. Delayed contrast-enhanced MRI: use in myocardial viability assessment and other cardiac pathology

    International Nuclear Information System (INIS)

    Bogaert, J.; Dymarkowski, S.

    2005-01-01

    As in other organs, tissue characterization is important for many cardiac diseases. For example, in ischemic heart disease, differentiation between reversibly and irreversibly damaged myocardium in patients with a prior myocardial infarction is crucial in determining disease severity, functional recovery and patient outcome. With the recent advent of the single inversion-recovery contrast-enhanced magnetic resonance imaging (MRI) sequence (delayed contrast-enhanced MRI), contrast between normal and abnormal tissues could be significantly enhanced compared with the conventional cardiac MRI sequences, enabling even subtle abnormalities to be visualized. Together with other advances in cardiac MRI (e.g. functional imaging, coronary artery imaging), MRI has become one of the preferred non-invasive modalities to study cardiac diseases. In this paper an overview of the versatility of delayed contrast-enhanced MRI for investigating cardiac diseases is given. (orig.)

  18. Dynamic contrast enhanced ultrasound for therapy monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, John M. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Williams, Ross [Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Tremblay-Darveau, Charles; Sheeran, Paul S. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Milot, Laurent [Department of Medical Imaging, University of Toronto, Toronto, ON (Canada); Bjarnason, Georg A. [Department of Medical Oncology, University of Toronto, and Sunnybrook Odette Cancer Centre, Toronto, ON (Canada); Burns, Peter N., E-mail: burns@sri.utoronto.ca [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Department of Medical Imaging, University of Toronto, Toronto, ON (Canada)

    2015-09-15

    Quantitative imaging is a crucial component of the assessment of therapies that target the vasculature of angiogenic or inflamed tissue. Dynamic contrast-enhanced ultrasound (DCE-US) using microbubble contrast offers the advantages of being sensitive to perfusion, non-invasive, cost effective and well suited to repeated use at the bedside. Uniquely, it employs an agent that is truly intravascular. This papers reviews the principles and methodology of DCE-US, especially as applied to anti-angiogenic cancer therapies. Reproducibility is an important attribute of such a monitoring method: results are discussed. More recent technical advances in parametric and 3D DCE-US imaging are also summarised and illustrated.

  19. Fast mutual-information-based contrast enhancement

    Science.gov (United States)

    Cao, Gang; Yu, Lifang; Tian, Huawei; Huang, Xianglin; Wang, Yongbin

    2017-07-01

    Recently, T. Celik proposed an effective image contrast enhancement (CE) method based on spatial mutual information and PageRank (SMIRANK). According to the state-of-the-art evaluation criteria, it achieves the best visual enhancement quality among existing global CE methods. However, SMIRANK runs much slower than the other counterparts, such as histogram equalization (HE) and adaptive gamma correction. Low computational complexity is also required for good CE algorithms. In this paper, we novelly propose a fast SMIRANK algorithm, called FastSMIRANK. It integrates both spatial and gray-level downsampling into the generation of pixel value mapping function. Moreover, the computation of rank vectors is speeded up by replacing PageRank with a simple yet efficient row-based operation of mutual information matrix. Extensive experimental results show that the proposed FastSMIRANK could accelerate the processing speed of SMIRANK by about 20 times, and is even faster than HE. Comparable enhancement quality is preserved simultaneously.

  20. Osteoblastic Metastases Mimickers on Contrast Enhanced CT

    Directory of Open Access Journals (Sweden)

    Fahad Al-Lhedan

    2017-01-01

    Full Text Available Secondary osseous involvement in lymphoma is more common compared to primary bone lymphoma. The finding of osseous lesion can be incidentally discovered during the course of the disease. However, osseous metastases are infrequently silent. Detection of osseous metastases is crucial for accurate staging and optimal treatment planning of lymphoma. The aim of imaging is to identify the presence and extent of osseous disease and to assess for possible complications such as pathological fracture of the load-bearing bones and cord compression if the lesion is spinal. We are presenting two patients with treated lymphoma who were in complete remission. On routine follow-up contrast enhanced CT, there were new osteoblastic lesions in the spine worrisome for metastases. Additional studies were performed for further evaluation of both of them which did not demonstrate any corresponding suspicious osseous lesion. The patients have a prior history of chronic venous occlusive thrombosis that resulted in collaterals formation. Contrast enhancement of the vertebral body marrow secondary to collaterals formation and venous flow through the vertebral venous plexus can mimic the appearance of spinal osteoblastic metastases.

  1. The role of contrast-enhanced ultrasonography in image-guided liver ablations

    International Nuclear Information System (INIS)

    Pescatori, Lorenzo Carlo; Sconfienza, Luca Maria; Mauri, Giovanni

    2016-01-01

    We read with great interest the paper by Kim et al. entitled “Local ablation therapy with contrast enhanced ultrasonography for hepatocellular carcinoma: a practical review,” recently published in Ultrasonography. We think that contrast-enhanced ultrasonography (CEUS), together with the development of reliable navigation systems, is likely to represent one of the most important advances in image-guided ablations in recent years. Thus, we offer some considerations on the topic

  2. Left Gastric Vein Visualization with Hepatopetal Flow Information in Healthy Subjects Using Non-Contrast-Enhanced Magnetic Resonance Angiography with Balanced Steady-State Free-Precession Sequence and Time-Spatial Labeling Inversion Pulse.

    Science.gov (United States)

    Furuta, Akihiro; Isoda, Hiroyoshi; Ohno, Tsuyoshi; Ono, Ayako; Yamashita, Rikiya; Arizono, Shigeki; Kido, Aki; Sakashita, Naotaka; Togashi, Kaori

    2018-01-01

    To selectively visualize the left gastric vein (LGV) with hepatopetal flow information by non-contrast-enhanced magnetic resonance angiography under a hypothesis that change in the LGV flow direction can predict the development of esophageal varices; and to optimize the acquisition protocol in healthy subjects. Respiratory-gated three-dimensional balanced steady-state free-precession scans were conducted on 31 healthy subjects using two methods (A and B) for visualizing the LGV with hepatopetal flow. In method A, two time-spatial labeling inversion pulses (Time-SLIP) were placed on the whole abdomen and the area from the gastric fornix to the upper body, excluding the LGV area. In method B, nonselective inversion recovery pulse was used and one Time-SLIP was placed on the esophagogastric junction. The detectability and consistency of LGV were evaluated using the two methods and ultrasonography (US). Left gastric veins by method A, B, and US were detected in 30 (97%), 24 (77%), and 23 (74%) subjects, respectively. LGV flow by US was hepatopetal in 22 subjects and stagnant in one subject. All hepatopetal LGVs by US coincided with the visualized vessels in both methods. One subject with non-visualized LGV in method A showed stagnant LGV by US. Hepatopetal LGV could be selectively visualized by method A in healthy subjects.

  3. Efficacy of perceptual vision therapy in enhancing visual acuity and contrast sensitivity function in adult hypermetropic anisometropic amblyopia

    Directory of Open Access Journals (Sweden)

    Yalcin E

    2013-12-01

    Full Text Available Elvan Yalcin, Ozlem BalciWorld Eye Hospital, Department of Pediatric Ophthalmology, Istanbul, TurkeyBackground: The purpose of this study was to evaluate the efficacy of neural vision therapy, also termed perceptual vision therapy, in enhancing best corrected visual acuity (BCVA and contrast sensitivity function in amblyopic patients.Methods: This prospective study enrolled 99 subjects previously diagnosed with unilateral hypermetropic amblyopia aged 9–50 years. The subjects were divided into two groups, with 53 subjects (53 eyes in the perceptual vision therapy group and 46 subjects (46 eyes in the control group. Because the nature of the treatment demands hard work and strict compliance, we enrolled the minimal number of subjects required to achieve statistically significant results. Informed consent was obtained from all subjects. Study phases included a baseline screening, a series of 45 training sessions with perceptual vision therapy, and an end-of-treatment examination. BCVA and contrast sensitivity function at 1.5, 3, 6, 12, and 18 cycles per degree spatial frequencies were obtained for statistical analysis in both groups. All subjects had follow-up examinations within 4–8 months. With the exception of one subject from the study group and two subjects from the control group, all subjects had occlusion during childhood. The study was not masked.Results: The results for the study group demonstrated a mean improvement of 2.6 logarithm of the minimum angle of resolution (logMAR lines in visual acuity (from 0.42 to 0.16 logMAR. Contrast sensitivity function improved at 1.5, 3, 6, 12, and 18 cycles per degree spatial frequencies. The control group did not show any significant change in visual acuity or contrast sensitivity function. None of the treated eyes showed a drop in visual acuity. Manifest refractions remained unchanged during the study.Conclusion: The results of our study demonstrate the efficacy of perceptual vision therapy in

  4. Value of the Gd-DTPA contrast enhanced MR in patients with failed back surgery syndrome

    International Nuclear Information System (INIS)

    Paprzycki, W.; Gradzki, J.; Sosnowski, P.; Stajgis, M.

    1994-01-01

    Gd-DTPA contrast - enhanced MR enables differentiation between postoperative scar and recurrent prolapse of nucleus pulposus (RPNP). Pre- and post-contrast MR studies in 40 patients with failed back surgery syndrome, previously treated surgically on 54 intervertebral levels, were evaluated. Presence of RPNP was confirmed on 4, postoperative scars on 35 and both condition on 15 invertebral levels. Correct interpretation of pathologic changes on 15 invertebral levels (28%) was only possible after contrast enhancement. Contrast enhancement of scar excluded the diagnosis of coexistence of RPNP and scar, based on pre-contrast MR studies. MR with Gd-DTPA contrast enhancement is the best diagnostic method in patients with failed back surgery syndrome (author)

  5. Isoattenuating insulinomas at biphasic contrast-enhanced CT: frequency, clinicopathologic features and perfusion characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Liang; Xue, Hua-dan; Sun, Hao; Wang, Xuan; He, Yong-lan; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)

    2016-10-15

    We aimed to determine the frequency of isoattenuating insulinomas, to investigate their clinicopathological features and to assess their regional pancreatic perfusion characteristics. Institutional review board approval was obtained, and patient informed consent was waived. From July 2010 to June 2014, 170 patients (66 male, 104 female) with endogenous hyperinsulinemic hypoglycemia underwent biphasic contrast-enhanced CT before surgery, and 129 of those patients also received preoperative whole-pancreas CT perfusion. A total of 181 tumours were proved histopathologically after surgery. Enhancement pattern and regional pancreatic perfusion characteristics were analyzed. Clinical features, tumour size and pathological grading were investigated. The frequency of isoattenuating tumours was 24.9 %. Tumour size and WHO grading was not significantly different between isoattenuating and hyperattenuating tumours. Tumour-free regions had identical blood flow (BF) regardless of their location (p = 0.35). Isoattenuating tumour-harbouring regions had lower BF compared with hyperattenuating tumour-harbouring regions; both showed higher BF compared with tumour-free neighbourhood regions (all p < 0.01). For patients with isoattenuating tumours, the overall hospital stay was longer (p < 0.01). A substantial subset of insulinomas were isoattenuating on biphasic CT. CT perfusion showed higher BF in tumour-harbouring regions compared to tumour-free regions, providing a clue for tumour regionalization. (orig.)

  6. Contrast-enhanced color Doppler US in breast cancer: Tumoral vascularity correlated with angiogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun A; Yoon, Kwon Ha; Yun, Ki Jung; Lee, Kwang Man; Park, Ki Han; Juhng, Seon Kwan; Won, Jong Jin [Wonkwang University School of Medicine, Seoul (Korea, Republic of)

    2000-12-15

    To evaluate the effects of contrast-enhanced color Doppler ultrasonography (CDUS) on the depiction of vascularity and flow pattern in breast cancer and to determine the relationship between tumoral vascularity and angiogenesis. Twenty-one patients with breast cancer were prospectively evaluated with CDUS before and after injection of the contrast agent (SH U 508A, 2.5g, 300 mg/ml ). The tumoral vascularity was expressed as percentage of color Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The flow pattern (four-patterns; spotty, linear, branching, marginal) of the vascularity was analyzed. After surgery, tumor angiogenesis was assessed by microvessel density. The relationship between the vascularity on CDUS and microvessel density was statistically analyzed. At unenhanced CDUS, tumoral flow signals were detected in 12 lesions (48%); at contrast-enhanced CDUS, 18 lesions (86%). All These 18 lesions showed increased signals, compared with those at unenhanced CDUS. The percentage color Doppler area was 1.86 {+-} 0.48% at unenhanced CDUS and 5.23 {+-} 1.18% at contrast-enhanced CDUS. The flow patterns before contrast injection were spotty pattern in 11 tumors and linear pattern in one; after contrast injection, spotty in 8, linear in 4, branching in 5, and marginal in one. The tumoral vascularity at contrast-enhanced CDUS showed no significant correlation with microvessel density. Contrast-enhanced CDUS seems to be a valuable tool in the depiction of vascularity and characterization of flow pattern in breast cancer. However, tumoral vascularity on CDUS may not reflect tumoral angiogenesis.

  7. Breast dynamic contrast enhanced MRI: fibrocystic changes presenting as a non-mass enhancement mimicking malignancy

    Directory of Open Access Journals (Sweden)

    Milosevic Zorica C.

    2017-06-01

    Full Text Available We aimed to analyse the morphokinetic features of breast fibrocystic changes (nonproliferative lesions, proliferative lesions without atypia and proliferative lesions with atypia presenting as a non-mass enhancement (NMEin dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI examination.

  8. Multipeak Mean Based Optimized Histogram Modification Framework Using Swarm Intelligence for Image Contrast Enhancement

    Directory of Open Access Journals (Sweden)

    P. Babu

    2015-01-01

    Full Text Available A novel approach, Multipeak mean based optimized histogram modification framework (MMOHM is introduced for the purpose of enhancing the contrast as well as preserving essential details for any given gray scale and colour images. The basic idea of this technique is the calculation of multiple peaks (local maxima from the original histogram. The mean value of multiple peaks is computed and the input image’s histogram is segmented into two subhistograms based on this multipeak mean (mmean value. Then, a bicriteria optimization problem is formulated and the subhistograms are modified by selecting optimal contrast enhancement parameters. While formulating the enhancement parameters, particle swarm optimization is employed to find optimal values of them. Finally, the union of the modified subhistograms produces a contrast enhanced and details preserved output image. This mechanism enhances the contrast of the input image better than the existing contemporary HE methods. The performance of the proposed method is well supported by the contrast enhancement quantitative metrics such as discrete entropy, natural image quality evaluator, and absolute mean brightness error.

  9. Contrast enhanced MR imaging of postoperative medulloblastoma in childhood: emphasis on meningeal enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Choong Gon; Kim, In One; Kim, Woo Sun; Kim, Ho Chul; Yeon, Kyung Mo [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1993-03-15

    To differentiate the postoperative changes from the recurrence of tumor and to evaluate MR imaging of early postoperative leptomeningeal seeding in medulloblastoma, We have retrospectively analysed 34 cases of MR images of 17 patients who were confirmed as medulloblastoma by histopathology. Noncontrast and postcontrast T1 weighted MR images were obtained in all patients. In 11 patients follow-up MR was done more than once (average: 1.5 times) and average interval of MR imaging was 6 months. The timing of 34 MR images was as follow: 6 case within 2 months, 9 cases between 2 months and 1 year, 19 cases more than 1 year after surgery respectively. MR images within 2 month after surgery revealed contrast enhancement at operation site and adjacent meninges, hemorrhage, residual tumor. In patients who had no evidence of tumor recurrence, these early postoperative changes were markedly decreased within 6 month after surgery. MR images obtained more than 1 year after surgery showed no abnormal contrast enhancement or mild focal dural enhancement at operation site. Diffuse moderate dural enhancement was noted in one patient who had the history of post-surgical subdural hemorrhage. In six patients with tumor recurrences which were detected from as early as 9 months to 6 years after surgery, the findings of recurrence included leptomeningeal enhancement of brain stem and cerebellar surface at early stage, variable sized enhancing leptomeningeal nodules, linear or irregular sulcus obliterating enhancing lesions, enhancing mass at primary or metastatic site. We have concluded that leptomeningeal enhancement detected after 6 months of surgery is an important MR finding suggesting the possibility of tumor recurrence. Small nodular and linear enhancement of leptomeninges at brainstem or cerebellar surface is considered as the early manifestation of intracranial tumor seeding.

  10. Contrast enhanced MR imaging of postoperative medulloblastoma in childhood: emphasis on meningeal enhancement

    International Nuclear Information System (INIS)

    Choi, Choong Gon; Kim, In One; Kim, Woo Sun; Kim, Ho Chul; Yeon, Kyung Mo

    1993-01-01

    To differentiate the postoperative changes from the recurrence of tumor and to evaluate MR imaging of early postoperative leptomeningeal seeding in medulloblastoma, We have retrospectively analysed 34 cases of MR images of 17 patients who were confirmed as medulloblastoma by histopathology. Noncontrast and postcontrast T1 weighted MR images were obtained in all patients. In 11 patients follow-up MR was done more than once (average: 1.5 times) and average interval of MR imaging was 6 months. The timing of 34 MR images was as follow: 6 case within 2 months, 9 cases between 2 months and 1 year, 19 cases more than 1 year after surgery respectively. MR images within 2 month after surgery revealed contrast enhancement at operation site and adjacent meninges, hemorrhage, residual tumor. In patients who had no evidence of tumor recurrence, these early postoperative changes were markedly decreased within 6 month after surgery. MR images obtained more than 1 year after surgery showed no abnormal contrast enhancement or mild focal dural enhancement at operation site. Diffuse moderate dural enhancement was noted in one patient who had the history of post-surgical subdural hemorrhage. In six patients with tumor recurrences which were detected from as early as 9 months to 6 years after surgery, the findings of recurrence included leptomeningeal enhancement of brain stem and cerebellar surface at early stage, variable sized enhancing leptomeningeal nodules, linear or irregular sulcus obliterating enhancing lesions, enhancing mass at primary or metastatic site. We have concluded that leptomeningeal enhancement detected after 6 months of surgery is an important MR finding suggesting the possibility of tumor recurrence. Small nodular and linear enhancement of leptomeninges at brainstem or cerebellar surface is considered as the early manifestation of intracranial tumor seeding

  11. Multislice CT of the liver. Effects of contrast material pushed with saline solution on hepatic enhancement

    International Nuclear Information System (INIS)

    Sekiguchi, Ryuzo; Hayashi, Takayuki; Tsukamoto, Tatsuaki; Kuroki, Yoshinori; Nasu, Katsuhiro; Murakami, Koji; Nawano, Shigeru

    2004-01-01

    The purpose of this study was to evaluate the usefulness of a method of power injection of contrast material pushed with saline solution for hepatic multislice CT using a dual-head power injector. One hundred twenty-one patients who underwent multislice CT to detect liver metastases were divided into two groups, depending on the protocol of contrast material administration: 100 mL of non-ionic contrast material (370 mgI/mL) or 100 mL of the same contrast material pushed with 30 mL of saline solution. Both contrast material and saline solution were administered at a rate of 2.5 mL/sec using a dual-head power injector. Attenuation values for the two protocols were obtained from the liver, portal vein, and descending aorta. Hepatic enhancement above 50 Hounsfield unit (HU), which is needed for the diagnosis of liver metastases, was achieved in 76.5% of patients given 100 mL of contrast material and 92.5% of those given 100 mL of contrast material pushed with a 30 mL saline solution. In contingency-table analysis, the CT attenuation value of liver categorized as less than 50 HU or more than 50 HU, showed a good relation between the categorized group and the protocol (p=0.0437). In patients with a body weight of 50 kg or more, 100 mL of contrast material pushed with saline solution provided significantly better CT attenuation values in the liver (p=0.0113), portal vein (p=0.0094), and descending aorta (p=0.0394) than those provided by the injection of 100 mL of contrast material alone. When contrast material pushed with saline solution was used, CT attenuation values in the liver were significantly increased, especially in patients with a body weight of 50 kg or more. This technique will provide a decrease in the volume of contrast material administered and a potential decrease in the side effects of contrast material. (author)

  12. Local Contrast Enhancement Utilizing Bidirectional Switching Equalization of Separated and Clipped Subhistograms

    Directory of Open Access Journals (Sweden)

    Haidi Ibrahim

    2014-01-01

    Full Text Available Digital image contrast enhancement methods that are based on histogram equalization technique are still useful for the use in consumer electronic products due to their simple implementation. However, almost all the suggested enhancement methods are using global processing technique, which does not emphasize local contents. Therefore, this paper proposes a new local image contrast enhancement method, based on histogram equalization technique, which not only enhances the contrast, but also increases the sharpness of the image. Besides, this method is also able to preserve the mean brightness of the image. In order to limit the noise amplification, this newly proposed method utilizes local mean-separation, and clipped histogram bins methodologies. Based on nine test color images and the benchmark with other three histogram equalization based methods, the proposed technique shows the best overall performance.

  13. Quantitative contrast-enhanced optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Winetraub, Yonatan; SoRelle, Elliott D. [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Biophysics Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Liba, Orly [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Electrical Engineering, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Zerda, Adam de la [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Biophysics Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Electrical Engineering, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States)

    2016-01-11

    We have developed a model to accurately quantify the signals produced by exogenous scattering agents used for contrast-enhanced Optical Coherence Tomography (OCT). This model predicts distinct concentration-dependent signal trends that arise from the underlying physics of OCT detection. Accordingly, we show that real scattering particles can be described as simplified ideal scatterers with modified scattering intensity and concentration. The relation between OCT signal and particle concentration is approximately linear at concentrations lower than 0.8 particle per imaging voxel. However, at higher concentrations, interference effects cause signal to increase with a square root dependence on the number of particles within a voxel. Finally, high particle concentrations cause enough light attenuation to saturate the detected signal. Predictions were validated by comparison with measured OCT signals from gold nanorods (GNRs) prepared in water at concentrations ranging over five orders of magnitude (50 fM to 5 nM). In addition, we validated that our model accurately predicts the signal responses of GNRs in highly heterogeneous scattering environments including whole blood and living animals. By enabling particle quantification, this work provides a valuable tool for current and future contrast-enhanced in vivo OCT studies. More generally, the model described herein may inform the interpretation of detected signals in modalities that rely on coherence-based detection or are susceptible to interference effects.

  14. Value of fat suppression and dynamic contrast-enhanced MRI in the diagnosis of insulinoma

    International Nuclear Information System (INIS)

    Xu Zengbin; Ruan Lingxiang; Peng Zhiyi; Zhang Minming; Xu Shunliang; Zhang Xidao

    2003-01-01

    Objective: To evaluate the value of fat suppression and dynamic contrast-enhanced MRI in the preoperative localization of insulinoma. Methods: Twelve cases with pathologically proven insulinoma were evaluated with MRI. SE T 1 WI, FSE T 2 WI, T 1 WI and T 2 WI with fat suppression, dynamic contrast-enhanced FMPSPGR sequences were used in MR scanning. Results: On SE T 1 WI, the lesions displayed hypointense in 4, isointense in 8 cases. Lesions showed hyperintense in 4, isointense in 8 cases on FSE T 2 WI. In contrast, 7 cases appeared as hypointense on T 1 WI with fat suppression and 6 cases appeared as hyperintense on T 2 WI with fat suppression. With dynamic contrast-enhanced FMPSPGR sequence 11 of 12 insulinomas were detected. In the arterial phase, the lesions presented as hyperintense with different degrees in 11 cases and isointense in 1 case. 6 cases remained hyperintense and 6 cases were isointense in pancreatic parenchymal and portal phase. 4 lesions were identified only in dynamic enhancement images. The diagnostic accuracy of insulinoma by dynamic contrast-enhanced MRI was 91.7% (11/12) as compared with histological study. Conclusion: The results indicate that dynamic contrast-enhanced MRI is an sensitive and accurate method for the preoperative localization of insulinoma

  15. Abdominal vascular and visceral parenchymal contrast enhancement in MDCT: Effects of injection duration

    Energy Technology Data Exchange (ETDEWEB)

    Tsuge, Yusuke, E-mail: tsugeu@cup.ocn.ne.jp [Department of Radiology, Kizawa Memorial Hospital, 590 Kobityo Shimokobi, Minokamo City, Gifu 505-8503 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University Hospital, Gifu (Japan); Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Goshima, Satoshi; Kondo, Hiroshi [Department of Radiology, Gifu University Hospital, Gifu (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University Hospital, Gifu (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka (Japan); Moriyama, Noriyuki [Research Center for Cancer Prevention and Screening, National Cancer Center Hospital, Tsukiji (Japan); Bae, Kyongtae T. [Radiology and Biomedical Engineering, University of Pittsburgh, Pittsburgh, PA (United States)

    2011-11-15

    Purpose: To evaluate and compare the effect of short and long injection durations on aortic, pancreatic and hepatic enhancement in abdominal MDCT. Methods and materials: Triphasic contrast-enhanced CT images (16-MDCT, 1.25-mm collimation, 5-mm thickness, 6.1-s acquisition time for each phase) were obtained with 2 mL/kg injection of 300 mgI/mL iodine contrast material in 116 patients. Patients were prospectively randomized into two groups: one receiving contrast medium for 25-s injection duration and the other for 35-s injection duration. In both groups, triphasic scans were initiated 5, 15, and 40 s after the completion of contrast injection for the first, second and third phases, respectively. CT values (HU) in the abdominal aorta, liver, spleen, pancreas, splenic and superior mesenteric arteries, and veins (splenic, superior mesenteric, portal, and hepatic) were measured. Quantitative and qualitative analysis for the degree of contrast enhancement between the two groups in various organs was compared at each scan phase. Results: The aortic and arterial enhancements in the first-phase scan were higher for the 25-s group than those of the 35-s group (P < .001). Hepatic enhancement was higher for the 35-s group in the first (P < .001) and second (P < .01) phases, but no difference in the third-phase. No difference was found between the groups for the pancreatic enhancement at any phases. Qualitative results were in good agreement with quantitative results. Conclusion: Contrast administration with shorter injection duration increased peak aortic and arterial enhancement and contributed to improvement in the quality of CT angiograms, but for the solid abdominal organs 35-s protocol is recommended.

  16. Contrast-enhanced magnetic resonance angiography of persistent fifth aortic arch in children

    International Nuclear Information System (INIS)

    Zhong, Yumin; Zhu, Ming; Sun, Aimin; Li, Yuhua; Jaffe, Richard B.; Gao, Wei

    2007-01-01

    Cine angiography and echocardiography have been utilized to diagnose congenital aortic arch anomalies. However, the visualization of great vessels by echocardiography is limited, while cine angiography requires cardiac catheterization with ionizing radiation. Contrast-enhanced magnetic resonance angiography (MRA) is a noninvasive modality suitable for visualization of congenital aortic arch anomalies. To evaluate the utility of contrast-enhanced MRA in the diagnosis of persistent fifth aortic arch, a rare congenital aortic arch anomaly, and to compare the diagnostic accuracy of MRA with that of echocardiography and cine angiography. In four pediatric patients, contrast-enhanced MRA studies were performed for diagnosing persistent fifth aortic arch. The findings of MRA were compared with echocardiographic findings and confirmed by cine angiography and operation. Transthoracic surface echocardiography noted an aberrant vessel arising from the ascending aorta in two of four patients; the etiology of this vessel was uncertain. In the other two patients a diagnosis of coarctation was made. Of the four patients, only one was diagnosed with interruption of the aortic arch. Contrast-enhanced MRA clarified uncertain echocardiographic findings, enabling the correct diagnosis of persistent fifth aortic arch with fourth aortic arch interruption in all four patients. Contrast-enhanced MRA is a safe, accurate, and fast imaging technique for the evaluation of persistent fifth aortic arch and may obviate the need for conventional cine angiography. Cardiac catheterization may be reserved for some types of complicated congenital heart disease and for obtaining hemodynamic information. (orig.)

  17. Contrast-enhanced harmonic ultrasound imaging in ablation therapy for primary hepatocellular carcinoma.

    Science.gov (United States)

    Minami, Yasunori; Kudo, Masatoshi

    2009-12-31

    The success rate of percutaneous radiofrequency (RF) ablation for hepatocellular carcinoma (HCC) depends on correct targeting via an imaging technique. However, RF electrode insertion is not completely accurate for residual HCC nodules because B-mode ultrasound (US), color Doppler, and power Doppler US findings cannot adequately differentiate between treated and viable residual tumor tissue. Electrode insertion is also difficult when we must identify the true HCC nodule among many large regenerated nodules in cirrhotic liver. Two breakthroughs in the field of US technology, harmonic imaging and the development of second-generation contrast agents, have recently been described and have demonstrated the potential to dramatically broaden the scope of US diagnosis of hepatic lesions. Contrast-enhanced harmonic US imaging with an intravenous contrast agent can evaluate small hypervascular HCC even when B-mode US cannot adequately characterize tumor. Therefore, contrast-enhanced harmonic US can facilitate RF ablation electrode placement in hypervascular HCC, which is poorly depicted by B-mode US. The use of contrast-enhanced harmonic US in ablation therapy for liver cancer is an efficient approach.

  18. Dynamic contrast-enhanced magnetic resonance imaging can assess vascularity within fracture non-unions and predicts good outcome

    Energy Technology Data Exchange (ETDEWEB)

    Schoierer, Oliver; Bender, Daniel; Schmidmaier, Gerhard [University Hospital Heidelberg, Heidelberg Trauma Research Group, Department of Orthopaedic and Trauma Surgery, Heidelberg (Germany); Bloess, Konstantin; Kauczor, Hans-Ulrich; Weber, Marc-Andre [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Burkholder, Iris [University of Applied Sciences of the Saarland, Department of Nursing and Health, Saarbruecken (Germany)

    2014-02-15

    To prospectively evaluate whether dynamic contrast-enhanced (DCE) MRI can assess vascularity within non-unions and predicts clinical outcome in combination with the clinical Non-Union Scoring System (NUSS). Fifty-eight patients with non-unions of extremities on CT underwent 3-T DCE MRI. Signal intensity curves obtained from a region-of-interest analysis were subdivided into those with more intense contrast agent uptake within the non-union than in adjacent muscle (vascularised non-union) and those with similar or less contrast uptake. The pharmacokinetic parameters of the Tofts model K{sub trans}, K{sub ep}, iAUC and V{sub e} were correlated with union at CT 1 year later (n = 49). Despite inserted osteosynthetic material, DCE parameters could be evaluated in 57 fractures. The sensitivity/specificity of vascularised non-unions as an indicator of good outcome was 83.9 %/50.0 % compared to 96.8 %/33.3 % using NUSS (n = 49). Logistic regression revealed a significant impact of NUSS on outcome (P = 0.04, odds ratio = 0.93). At first examination, median iAUC (initial area under the enhancement curve) for the ratio non-union/muscle was 10.28 in patients with good outcome compared with 3.77 in non-responders (P = 0.023). K{sub trans}, K{sub ep} and V{sub e} within the non-union were not significantly different initially (n = 57) or 1 year later (n = 19). DCE MRI can assess vascularity in fracture non-unions. A vascularised non-union correlates with good outcome. (orig.)

  19. Accuracy of contrast-enhanced dual-energy MDCT for the assessment of iodine uptake in renal lesions.

    Science.gov (United States)

    Mileto, Achille; Marin, Daniele; Ramirez-Giraldo, Juan Carlos; Scribano, Emanuele; Krauss, Bernhard; Mazziotti, Silvio; Ascenti, Giorgio

    2014-05-01

    The objective of our study was to assess the accuracy of iodine-related attenuation and iodine quantification as imaging biomarkers of iodine uptake in renal lesions on a single-phase nephrographic image with dual-energy MDCT. Fifty-nine patients (41 men, 18 women; age range, 28-84 years) with 80 renal lesions underwent contrast-enhanced dual-energy CT during the nephrographic phase of enhancement. Renal lesions were characterized as enhancing or nonenhancing on color-coded iodine overlay maps using iodine-related attenuation (in Hounsfield units) and iodine quantification (in milligrams per milliliter). For iodine-related attenuation the iodine uptake thresholds of 15 and 20 HU were tested; a threshold of 0.5 mg/mL was used for iodine quantification. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of iodine-related attenuation and iodine quantification were calculated from chi-square tests of contingency with histopathology or imaging follow-up as the reference standard. The 95% CIs were calculated from binomial expression. Differences in sensitivity and specificity were assessed by means of McNemar analysis. A significant difference in sensitivity and specificity was found between iodine-related attenuation with the thresholds of 15 HU (sensitivity, 91.4%; specificity, 93.3%; PPV, 91.4%; NPV, 93.3%) and 20 HU (sensitivity, 77.1%; specificity, 100%; PPV, 100%; NPV, 84.9%) (p = 0.008) and between iodine quantification (sensitivity, 100%; specificity, 97.7%; PPV, 97.2%; NPV, 100%) and iodine-related attenuation with a threshold of 20 HU (p = 0.004). No significant difference in sensitivity and specificity was found between iodine quantification and iodine-related attenuation with a threshold of 15 HU. Contrast-enhanced dual-energy MDCT with iodine-related attenuation and iodine quantification allows accurate evaluation of iodine uptake in renal lesions on a single-phase nephrographic image.

  20. Efficient contrast enhancement through log-power histogram modification

    NARCIS (Netherlands)

    Wu, T.; Toet, A.

    2014-01-01

    A simple power-logarithm histogram modification operator is proposed to enhance digital image contrast. First a logarithm operator reduces the effect of spikes and transforms the image histogram into a smoothed one that approximates a uniform histogram while retaining the relative size ordering of

  1. Improvement of Fuzzy Image Contrast Enhancement Using Simulated Ergodic Fuzzy Markov Chains

    Directory of Open Access Journals (Sweden)

    Behrouz Fathi-Vajargah

    2014-01-01

    Full Text Available This paper presents a novel fuzzy enhancement technique using simulated ergodic fuzzy Markov chains for low contrast brain magnetic resonance imaging (MRI. The fuzzy image contrast enhancement is proposed by weighted fuzzy expected value. The membership values are then modified to enhance the image using ergodic fuzzy Markov chains. The qualitative performance of the proposed method is compared to another method in which ergodic fuzzy Markov chains are not considered. The proposed method produces better quality image.

  2. Research on Wavelet-Based Algorithm for Image Contrast Enhancement

    Institute of Scientific and Technical Information of China (English)

    Wu Ying-qian; Du Pei-jun; Shi Peng-fei

    2004-01-01

    A novel wavelet-based algorithm for image enhancement is proposed in the paper. On the basis of multiscale analysis, the proposed algorithm solves efficiently the problem of noise over-enhancement, which commonly occurs in the traditional methods for contrast enhancement. The decomposed coefficients at same scales are processed by a nonlinear method, and the coefficients at different scales are enhanced in different degree. During the procedure, the method takes full advantage of the properties of Human visual system so as to achieve better performance. The simulations demonstrate that these characters of the proposed approach enable it to fully enhance the content in images, to efficiently alleviate the enhancement of noise and to achieve much better enhancement effect than the traditional approaches.

  3. Comparison of Allergic Adverse Effects and Contrast Enhancement Between Iodixanol and Iopromide

    International Nuclear Information System (INIS)

    Gharekhanloo, Farideh; Torabian, Saadat

    2012-01-01

    Iodinated X-ray contrast media are the most commonly used contrast agents in the world with an annual application of 40-50 million. New non-ionic contrast agents are subdivided into low osmolar agents such as iopromide and iso-osmolar agents such as iodixanol. Regarding different biochemical characteristics, these agents are different in the allergic reactions and contrast enhancement and final lesion conspicuity. This study was carried out to compare allergic adverse effects and contrast enhancement between iodixanol and iopromide. One-hundred and twenty patients who were referred for abdominal CT scan to Besat Hospital were included in this study. Patients were randomly divided into two groups (A and B). Group A received 100 cc iodixanol (300 mgI/mL) and group B received 100 cc iopromide (300 mgI/ml) by power injector. CT examination was performed using Helical CT Scanner (Somatom, Siemens, Germany). Sixty seconds after injection, images were obtained and enhancement of port, liver and aorta were determined. Allergic adverse effects were recorded one hour and up to one week after injection. Iodixanol produced a significantly greater enhancement of the hepatic, aorta and portal vein than iopromide (P < 0.01). Sixty seconds after injection, associated pain and heat sensation were less frequent in iodixanol in comparison with iopromide (P = 0.03). Immediate reactions such as nausea and vomiting were less frequent in iodixanol (P = 0.01). Late skin reactions such as rash was more frequent in iodixanol (P < 0.01). Iodixanol is safe and is better tolerated in the early phase of injection with better contrast enhancement and lesion conspicuity. Mild late skin rash is its disadvantage

  4. A prospective study on contrast-enhanced magnetic resonance imaging of testicular lesions: distinctive features of Leydig cell tumours

    International Nuclear Information System (INIS)

    Manganaro, Lucia; Vinci, Valeria; Saldari, Matteo; Bernardo, Silvia; Cantisani, Vito; Catalano, Carlo; Pozza, Carlotta; Gianfrilli, Daniele; Pofi, Riccardo; Lenzi, Andrea; Isidori, Andrea M.; Scialpi, Michele

    2015-01-01

    Up to 20 % of incidentally found testicular lesions are benign Leydig cell tumours (LCTs). This study evaluates the role of contrast-enhanced magnetic resonance imaging (MRI) in the identification of LCTs in a large prospective cohort study. We enrolled 44 consecutive patients with at least one solid non-palpable testicular lesion who underwent scrotal MRI. Margins of the lesions, signal intensity and pattern of wash-in and wash-out were analysed by two radiologists. The frequency distribution of malignant and benign MRI features in the different groups was compared by using the chi-squared or Fisher's exact test. Sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy were calculated. The sensitivity of scrotal MRI to diagnose LCTs was 89.47 % with 95.65 % specificity; sensitivity for malignant lesions was 95.65 % with 80.95 % specificity. A markedly hypointense signal on T2-WI, rapid and marked wash-in followed by a prolonged washout were distinctive features significantly associated with LCTs. Malignant lesions were significantly associated with blurred margins, weak hypointense signal on T2-WI,and weak and progressive wash-in. The overall diagnostic accuracy was 93 %. LCTs have distinctive contrast-enhanced MRI features that allow the differential diagnosis of incidental testicular lesions. (orig.)

  5. A prospective study on contrast-enhanced magnetic resonance imaging of testicular lesions: distinctive features of Leydig cell tumours

    Energy Technology Data Exchange (ETDEWEB)

    Manganaro, Lucia; Vinci, Valeria; Saldari, Matteo; Bernardo, Silvia; Cantisani, Vito; Catalano, Carlo [Sapienza University of Rome, Department of Radiology, Rome (Italy); Pozza, Carlotta; Gianfrilli, Daniele; Pofi, Riccardo; Lenzi, Andrea; Isidori, Andrea M. [Sapienza University of Rome, Department of Experimental Medicine, Rome (Italy); Scialpi, Michele [Perugia University, S. Maria della Misericordia Hospital, Department of Surgical and Biomedical Sciences, Division of Radiology 2, Perugia (Italy)

    2015-12-15

    Up to 20 % of incidentally found testicular lesions are benign Leydig cell tumours (LCTs). This study evaluates the role of contrast-enhanced magnetic resonance imaging (MRI) in the identification of LCTs in a large prospective cohort study. We enrolled 44 consecutive patients with at least one solid non-palpable testicular lesion who underwent scrotal MRI. Margins of the lesions, signal intensity and pattern of wash-in and wash-out were analysed by two radiologists. The frequency distribution of malignant and benign MRI features in the different groups was compared by using the chi-squared or Fisher's exact test. Sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy were calculated. The sensitivity of scrotal MRI to diagnose LCTs was 89.47 % with 95.65 % specificity; sensitivity for malignant lesions was 95.65 % with 80.95 % specificity. A markedly hypointense signal on T2-WI, rapid and marked wash-in followed by a prolonged washout were distinctive features significantly associated with LCTs. Malignant lesions were significantly associated with blurred margins, weak hypointense signal on T2-WI,and weak and progressive wash-in. The overall diagnostic accuracy was 93 %. LCTs have distinctive contrast-enhanced MRI features that allow the differential diagnosis of incidental testicular lesions. (orig.)

  6. Influence of hyperosmotic agent (glycerol) in contrast enhancement

    International Nuclear Information System (INIS)

    Moriyama, Takashi; Suzuki, Shigeharu; Nakaoka, Tsutomu

    1981-01-01

    For getting a better contrast enhancement (CE) of computed tomography (CT) in brain tumors, we tried to increase the extravascular iodine concentration. A vailing ourselves of the period of returning water following intravenously administered glycerol, a drip injection of the contrast medium gave a better CE effect than the usual CE. In two benign gliomas, CE with glycerol was much better than CE without glycerol, and in two malignant gliomas and two metastatic tumors, CE with glycerol was better, but not so much better as with the benign tumors. In general, the CE effect in primary brain tumors showed a decreasing pattern, whereas in metastatic brain tumors the best time was 60 minutes after the injection of the contrast material (increasing and decreasing pattern), suggesting an increase in the extravascular iodine and a severe failure of the blood brain barrier. Two cystic malignant gliomas allowed the intravenously injected contrast medium to enter the cysts. It appears that the contrast medium passes through and/or is secreted from the wall of the cyst. (author)

  7. AN ILLUMINATION INVARIANT FACE RECOGNITION BY ENHANCED CONTRAST LIMITED ADAPTIVE HISTOGRAM EQUALIZATION

    Directory of Open Access Journals (Sweden)

    A. Thamizharasi

    2016-05-01

    Full Text Available Face recognition system is gaining more importance in social networks and surveillance. The face recognition task is complex due to the variations in illumination, expression, occlusion, aging and pose. The illumination variations in image are due to changes in lighting conditions, poor illumination, low contrast or increased brightness. The variations in illumination adversely affect the quality of image and recognition accuracy. The illumination variations in face image have to be pre-processed prior to face recognition. The Contrast Limited Adaptive Histogram Equalization (CLAHE is an image enhancement technique popular in enhancing medical images. The proposed work is to create illumination invariant face recognition system by enhancing Contrast Limited Adaptive Histogram Equalization technique. This method is termed as “Enhanced CLAHE”. The efficiency of Enhanced CLAHE is tested using Fuzzy K Nearest Neighbour classifier and fisher face subspace projection method. The face recognition accuracy percentage rate, Equal Error Rate and False Acceptance Rate at 1% are calculated. The performance of CLAHE and Enhanced CLAHE methods is compared. The efficiency of the Enhanced CLAHE method is tested with three public face databases AR, Yale and ORL. The Enhanced CLAHE has very high recognition accuracy percentage rate when compared to CLAHE.

  8. Comparison of Background Parenchymal Enhancement at Contrast-enhanced Spectral Mammography and Breast MR Imaging.

    Science.gov (United States)

    Sogani, Julie; Morris, Elizabeth A; Kaplan, Jennifer B; D'Alessio, Donna; Goldman, Debra; Moskowitz, Chaya S; Jochelson, Maxine S

    2017-01-01

    Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material-enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board-approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%-76%) and MR imaging (69%-76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55-0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P spectral mammographic and MR images. © RSNA, 2016.

  9. Contrast-enhanced magnetic resonance imaging for the detection of acute haemorrhagic necrotizing pancreatitis

    International Nuclear Information System (INIS)

    Piironen, A.; Kivisaari, R.; Pitkaeranta, P.; Poutanen, V.P.; Laippala, P.; Laurila, P.; Kivisaari, L.

    1997-01-01

    Eleven piglets with haemorrhagic necrotizing pancreatitis and nine piglets with oedematous pancreatitis were imaged using a multi-breath-hold TurboFLASH (TR 6.5 ms, TE 3 ms, TI 300 ms, flip angle 8 , three slices) pre-excited T1-weighted sequence with an IV bolus injection of gadopentetate dimeglumine (Gd-DTPA, 0.3 mmol/kg) as a contrast agent to show dynamic contrast enhancement of the pancreas by MRI. All piglets were imaged according to the same protocol before inducing the disease. Following the IV Gd-DTPA bolus, time-enhancement curve of the pancreas during haemorrhagic necrotizing pancreatitis was significantly lower than during oedematous pancreatitis. The enhancement curves for the healthy piglets and piglets with oedematous pancreatitis did not differ significantly. Each piglet served as its own control. Because the results of this initial study are similar to those obtained with contrast-enhanced CT, we conclude that our results may encourage further clinical trials, and contrast-enhanced dynamic MRI may be an alternative to the established method of CT for diagnosing acute haemorrhagic necrotizing pancreatitis. (orig.). With 3 figs

  10. Ring-enhancement pattern on contrast-enhanced CT predicts adenosquamous carcinoma of the pancreas: a matched case-control study.

    Science.gov (United States)

    Imaoka, Hiroshi; Shimizu, Yasuhiro; Mizuno, Nobumasa; Hara, Kazuo; Hijioka, Susumu; Tajika, Masahiro; Tanaka, Tsutomu; Ishihara, Makoto; Ogura, Takeshi; Obayashi, Tomohiko; Shinagawa, Akihide; Sakaguchi, Masafumi; Yamaura, Hidekazu; Kato, Mina; Niwa, Yasumasa; Yamao, Kenji

    2014-01-01

    Adenosquamous carcinoma of the pancreas (ASC) is a rare malignant neoplasm of the pancreas, exhibiting both glandular and squamous differentiation. However, little is known about its imaging features. This study examined the imaging features of pancreatic ASC. We evaluated images of contrast-enhanced computed tomography (CT) and endoscopic ultrasonography (EUS). As controls, solid pancreatic neoplasms matched in a 2:1 ratio to ASC cases for age, sex and tumor location were also evaluated. Twenty-three ASC cases were examined, and 46 solid pancreatic neoplasms (43 pancreatic ductal adenocarcinomas, two pancreatic neuroendocrine tumors and one acinar cell carcinoma) were matched as controls. Univariate analysis demonstrated significant differences in the outline and vascularity of tumors on contrast-enhanced CT in the ASC and control groups (P outline, cystic changes, and the ring-enhancement pattern on contrast-enhanced CT were seen to have significant predictive powers by stepwise forward logistic regression analysis (P = 0.044, P = 0.010, and P = 0.001, respectively). Of the three, the ring-enhancement pattern was the most useful, and its predictive diagnostic sensitivity, specificity, positive predictive value and negative predictive value for diagnosis of ASC were 65.2%, 89.6%, 75.0% and 84.3%, respectively. These results demonstrate that presence of the ring-enhancement pattern on contrast-enhanced CT is the most useful predictive factor for ASC. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  11. Neutral vs positive oral contrast in diagnosing acute appendicitis with contrast-enhanced CT: sensitivity, specificity, reader confidence and interpretation time

    Science.gov (United States)

    Naeger, D M; Chang, S D; Kolli, P; Shah, V; Huang, W; Thoeni, R F

    2011-01-01

    Objective The study compared the sensitivity, specificity, confidence and interpretation time of readers of differing experience in diagnosing acute appendicitis with contrast-enhanced CT using neutral vs positive oral contrast agents. Methods Contrast-enhanced CT for right lower quadrant or right flank pain was performed in 200 patients with neutral and 200 with positive oral contrast including 199 with proven acute appendicitis and 201 with other diagnoses. Test set disease prevalence was 50%. Two experienced gastrointestinal radiologists, one fellow and two first-year residents blindly assessed all studies for appendicitis (2000 readings) and assigned confidence scores (1=poor to 4=excellent). Receiver operating characteristic (ROC) curves were generated. Total interpretation time was recorded. Each reader's interpretation with the two agents was compared using standard statistical methods. Results Average reader sensitivity was found to be 96% (range 91–99%) with positive and 95% (89–98%) with neutral oral contrast; specificity was 96% (92–98%) and 94% (90–97%). For each reader, no statistically significant difference was found between the two agents (sensitivities p-values >0.6; specificities p-values>0.08), in the area under the ROC curve (range 0.95–0.99) or in average interpretation times. In cases without appendicitis, positive oral contrast demonstrated improved appendix identification (average 90% vs 78%) and higher confidence scores for three readers. Average interpretation times showed no statistically significant differences between the agents. Conclusion Neutral vs positive oral contrast does not affect the accuracy of contrast-enhanced CT for diagnosing acute appendicitis. Although positive oral contrast might help to identify normal appendices, we continue to use neutral oral contrast given its other potential benefits. PMID:20959365

  12. Deep learning enables reduced gadolinium dose for contrast-enhanced brain MRI.

    Science.gov (United States)

    Gong, Enhao; Pauly, John M; Wintermark, Max; Zaharchuk, Greg

    2018-02-13

    There are concerns over gadolinium deposition from gadolinium-based contrast agents (GBCA) administration. To reduce gadolinium dose in contrast-enhanced brain MRI using a deep learning method. Retrospective, crossover. Sixty patients receiving clinically indicated contrast-enhanced brain MRI. 3D T 1 -weighted inversion-recovery prepped fast-spoiled-gradient-echo (IR-FSPGR) imaging was acquired at both 1.5T and 3T. In 60 brain MRI exams, the IR-FSPGR sequence was obtained under three conditions: precontrast, postcontrast images with 10% low-dose (0.01mmol/kg) and 100% full-dose (0.1 mmol/kg) of gadobenate dimeglumine. We trained a deep learning model using the first 10 cases (with mixed indications) to approximate full-dose images from the precontrast and low-dose images. Synthesized full-dose images were created using the trained model in two test sets: 20 patients with mixed indications and 30 patients with glioma. For both test sets, low-dose, true full-dose, and the synthesized full-dose postcontrast image sets were compared quantitatively using peak-signal-to-noise-ratios (PSNR) and structural-similarity-index (SSIM). For the test set comprised of 20 patients with mixed indications, two neuroradiologists scored blindly and independently for the three postcontrast image sets, evaluating image quality, motion-artifact suppression, and contrast enhancement compared with precontrast images. Results were assessed using paired t-tests and noninferiority tests. The proposed deep learning method yielded significant (n = 50, P 5 dB PSNR gains and >11.0% SSIM). Ratings on image quality (n = 20, P = 0.003) and contrast enhancement (n = 20, P deep learning method, gadolinium dose can be reduced 10-fold while preserving contrast information and avoiding significant image quality degradation. 3 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  13. Mercury toxicity in the Amazon: contrast sensitivity and color discrimination of subjects exposed to mercury

    Directory of Open Access Journals (Sweden)

    A.R. Rodrigues

    2007-03-01

    Full Text Available We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55% performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81%. Three gold miners and 1 riverine (4/19 subjects, 21% performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50%, comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity.

  14. Variational contrast enhancement guided by global and local contrast measurements for single-image defogging

    Science.gov (United States)

    Zhou, Li; Bi, Du-Yan; He, Lin-Yuan

    2015-01-01

    The visibility of images captured in foggy conditions is impaired severely by a decrease in the contrasts of objects and veiling with a characteristic gray hue, which may limit the performance of visual applications out of doors. Contrast enhancement together with color restoration is a challenging mission for conventional fog-removal methods, as the degrading effect of fog is largely dependent on scene depth information. Nowadays, people change their minds by establishing a variational framework for contrast enhancement based on a physically based analytical model, unexpectedly resulting in color distortion, dark-patch distortion, or fuzzy features of local regions. Unlike previous work, our method treats an atmospheric veil as a scattering disturbance and formulates a foggy image as an energy functional minimization to estimate direct attenuation, originating from the work of image denoising. In addition to a global contrast measurement based on a total variation norm, an additional local measurement is designed in that optimal problem for the purpose of digging out more local details as well as suppressing dark-patch distortion. Moreover, we estimate the airlight precisely by maximization with a geometric constraint and a natural image prior in order to protect the faithfulness of the scene color. With the estimated direct attenuation and airlight, the fog-free image can be restored. Finally, our method is tested on several benchmark and realistic images evaluated by two assessment approaches. The experimental results imply that our proposed method works well compared with the state-of-the-art defogging methods.

  15. Computer-aided diagnosis in contrast-enhanced CT colonography: an approach based on contrast

    International Nuclear Information System (INIS)

    Luboldt, Wolfgang; Kroll, Manuela; Vogl, Thomas J.; Mann, Carolin; Vonthein, Reinhard; Stueker, Dietmar; Luz, Oliver; Claussen, Claus D.; Tryon, Cathy L.

    2002-01-01

    Automation in colorectal mass detection is achieved as soon as the voxels representing colorectal masses can be automatically segmented. We tested the Hounsfield (HU) value in intensely contrast enhanced high-resolution CT colonography for automated segmentation of colorectal masses in 18 patients with 35 polyps (28<10 mm, 7 ≥10 mm) and 7 carcinomas. Mean HU values of the colonic wall and masses were determined to deduce a gradient threshold for a segmentation process, which encodes the voxels bordering the colonic lumen with a colour ranging in intensity from 0 to 100% according to the selected gradient threshold range in the volume rendering. The results of the automated segmentation process were superimposed on a virtual double contrast and endoscopic display and validated through correlation with morphology. Mean HU values and their standard deviations for the colonic wall, polyps <10 mm, polyps ≥10 mm and carcinomas were 63±24, 154±38, 116±41 and 108±29 HU, respectively. A gradient threshold ranging from 90 to 160 HU resulted in colour pools in 6 of 7 of polyps ≥10 mm, and 6 of 7 carcinomas that were significant enough to prospectively guide the reader's attention to these masses. Due to the superposition of ''false-positive'' voxels in the projection view, the virtual endoscopic perspective was superior to the virtual double contrast display for controlling the segmentation results. The HU value is promising for automated segmentation of colorectal masses but needs to be combined with morphological parameters to render automated colorectal mass detection more accurate. Further refinements of the method with subsequent analysis of its accuracy, as well as analogue studies with contrast-enhanced MRI, appear warranted. More information at http://www.multiorganscreening.org (orig.)

  16. Use of Iodine-based contrast media in digital full-field mammography - initial experience

    International Nuclear Information System (INIS)

    Diekmann, F.; Diekmann, S.; Taupitz, M.; Bick, U.; Winzer, K.-J.; Huettner, C.; Muller, S.; Jeunehomme, F.; Hamm, B.

    2003-01-01

    Aim: To investigate the use of iodine-based contrast media in digital full-field mammography. Methods: After performing initial phantom studies, seven patients underwent digital mammography (Senographe 2000D, GE Medical Systems, Milwaukee, USA) using a specially filtered beam before as well as 60, 120, and 180 seconds after injection of 80 ml of iodine contrast medium (Ultravist 370, Schering AG, Germany). The precontrast mammograms were then subtracted from the postcontrast mammograms and the resulting images compared with a contrast-enhanced dynamic MRI study, performed on all women. Results: Contrast medium accumulation within the tumors was visualized with a good quality in all cases. The conditions under which successful contrast-enhanced digital mammography can be performed were determined in phantom studies. Conclusions: Contrast-enhanced digital mammography has a potential for improving the visualization of breast tumors in mammography using special beam filtering, adjusted X-ray parameters, proper timing, and suitable subtraction software. (orig.) [de

  17. Contrast-enhanced voiding urosonography: in vitro evaluation of a second-generation ultrasound contrast agent for in vivo optimization.

    Science.gov (United States)

    Back, Susan J; Edgar, J Christopher; Canning, Douglas A; Darge, Kassa

    2015-09-01

    Pediatric contrast-enhanced ultrasound (CEUS) is primarily performed outside the United States where a track record for safety in intravenous and intravesical applications has been established. Contrast-enhanced voiding urosonography (ceVUS) has also been shown to have a much higher rate of vesicoureteral reflux detection compared to voiding cystourethrography. US contrast agents available in the United States differ from those abroad. Optison® (GE Healthcare, Princeton, NJ) is such an US contrast agent. While Optison® has similar characteristics to other second-generation agents, it has never been used for ceVUS. In vitro optimization of dose and imaging parameters as well as assessment of contrast visualization when delivered in conditions similar to ceVUS are necessary starting points prior to in vivo applications. To optimize the intravesical use of Optison® in vitro for ceVUS before its use in pediatric studies. The experimental design simulated intravesical use. Using 9- and 12-MHz linear transducers, we scanned 20-mL syringes varying mechanical index, US contrast agent concentration (0.25%, 0.5%, 1.0%), solvent (saline, urine, radiographic contrast agent) and time out of refrigeration. We evaluated mechanical index settings and contrast duration, optimized the contrast dose, measured the effect of urine and radiographic contrast agent, and the impact of length of time of contrast outside of the refrigerator on US contrast appearance. We scanned 50-ml saline bags to assess the appearance and duration of US contrast with different delivery systems (injection vs. infusion). Consistent contrast visualization was achieved at a mechanical index of 0.06-0.17 and 0.11-0.48 for the L9 and L12 MHz transducers (P contrast visualization of the microbubbles with a higher transducer frequency. The lowest mechanical index for earliest visible microbubble destruction was 0.21 for the 9 MHz and 0.39 for the 12 MHz (P contrast agent volume to bladder filling was the

  18. Differential diagnosis between pulmonary tuberculosis and lung abscess by contrast enhanced CT

    International Nuclear Information System (INIS)

    Kanauchi, Tetsu; Hoshi, Toshiko; Konno, Miyuki; Hando, Yumiko

    2001-01-01

    The contrast enhanced CT findings in 14 patients with active tuberculosis and 26 patients with lung abscess were retrospectively analyzed. Reflecting the difference of pathogenesis between tuberculosis and abscess, the findings are widely different. The findings suggesting pulmonary tuberculosis rather than lung abscess were as follows; multiple and irregular necrotic areas, positive CT angiogram sign, no marginal enhancement surrounding necrosis. Contrast enhanced CT may help to distinguish pulmonary tuberculosis from lung abscess, especially in cases of caseous pneumonia showing broad consolidations or mass-like shadows. (author)

  19. Counter-propagating wave interaction for contrast-enhanced ultrasound imaging

    Science.gov (United States)

    Renaud, G.; Bosch, J. G.; ten Kate, G. L.; Shamdasani, V.; Entrekin, R.; de Jong, N.; van der Steen, A. F. W.

    2012-11-01

    Most techniques for contrast-enhanced ultrasound imaging require linear propagation to detect nonlinear scattering of contrast agent microbubbles. Waveform distortion due to nonlinear propagation impairs their ability to distinguish microbubbles from tissue. As a result, tissue can be misclassified as microbubbles, and contrast agent concentration can be overestimated; therefore, these artifacts can significantly impair the quality of medical diagnoses. Contrary to biological tissue, lipid-coated gas microbubbles used as a contrast agent allow the interaction of two acoustic waves propagating in opposite directions (counter-propagation). Based on that principle, we describe a strategy to detect microbubbles that is free from nonlinear propagation artifacts. In vitro images were acquired with an ultrasound scanner in a phantom of tissue-mimicking material with a cavity containing a contrast agent. Unlike the default mode of the scanner using amplitude modulation to detect microbubbles, the pulse sequence exploiting counter-propagating wave interaction creates no pseudoenhancement behind the cavity in the contrast image.

  20. Counter-propagating wave interaction for contrast-enhanced ultrasound imaging

    International Nuclear Information System (INIS)

    Renaud, G; Bosch, J G; Ten Kate, G L; De Jong, N; Van der Steen, A F W; Shamdasani, V; Entrekin, R

    2012-01-01

    Most techniques for contrast-enhanced ultrasound imaging require linear propagation to detect nonlinear scattering of contrast agent microbubbles. Waveform distortion due to nonlinear propagation impairs their ability to distinguish microbubbles from tissue. As a result, tissue can be misclassified as microbubbles, and contrast agent concentration can be overestimated; therefore, these artifacts can significantly impair the quality of medical diagnoses. Contrary to biological tissue, lipid-coated gas microbubbles used as a contrast agent allow the interaction of two acoustic waves propagating in opposite directions (counter-propagation). Based on that principle, we describe a strategy to detect microbubbles that is free from nonlinear propagation artifacts. In vitro images were acquired with an ultrasound scanner in a phantom of tissue-mimicking material with a cavity containing a contrast agent. Unlike the default mode of the scanner using amplitude modulation to detect microbubbles, the pulse sequence exploiting counter-propagating wave interaction creates no pseudoenhancement behind the cavity in the contrast image. (fast track communication)

  1. Role of contrast-enhanced MR venography in the preoperative evaluation of parasagittal meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Bozzao, Alessandro; Finocchi, Vanina; Romano, Andrea; Ferrante, Michele; Fasoli, Fabrizio; Fantozzi, Luigi Maria [S. Andrea Hospital, Neuroradiological Section, Rome (Italy); Trillo, Giuseppe; Ferrante, Luigi [S. Andrea Hospital, Neurosurgical Section, Rome (Italy)

    2005-09-01

    Parasagittal meningiomas (PSM) may pose a difficult surgical challenge since venous patency and collateral anastomoses have to be clearly defined for correct surgical planning. The aim of this study was to assess the diagnostic value of contrast-enhanced (CE) magnetic resonance venography (MRV) in the preoperative evaluation of venous infiltration and collateral venous anastomoses in patients with PSM. CE-MRV was compared with phase-contrast (PC) magnetic resonance (MR) angiography, conventional angiography (when available), and surgery as a reference. Twenty-three patients undergoing surgery for meningiomas located adjacent to the superior sagittal sinus were prospectively evaluated. All the patients underwent both conventional MR examination and MRV. This was performed by means of PC and CE techniques. Both sets of angiograms (CE and PC) were evaluated by two expert neuroradiologists to assess (1) patency of the sinus (patent/occluded), (2) the extent of occlusion (in centimeters), and (3) the number of collateral anastomoses close to the insertion of the meningioma. Eight patients underwent digital subtraction angiography (DSA). All patients were operated on, and intraoperative findings were taken as the gold standard to evaluate the diagnostic value of MRA techniques. PC-MRV showed a flow void inside the sinus compatible with its occlusion in 15 cases, whereas CE-MRV showed the sinus to be occluded in five cases. CE-MRV data were confirmed by surgery, showing five patients to have an occlusion of the superior sagittal sinus. The PC-MRV sensitivity was thus 100% with a specificity of 50%. In those cases in which both MRV techniques documented occlusion of the sinus, the extent of occlusion was overestimated by PC compared with CE and surgery. CE-MRV depicted 87% of collateral venous anastomoses close to the meningioma as subsequently confirmed by surgery, while PC showed 58%. In the preoperative planning for patients with meningiomas located close to a venous

  2. Role of contrast-enhanced MR venography in the preoperative evaluation of parasagittal meningiomas

    International Nuclear Information System (INIS)

    Bozzao, Alessandro; Finocchi, Vanina; Romano, Andrea; Ferrante, Michele; Fasoli, Fabrizio; Fantozzi, Luigi Maria; Trillo, Giuseppe; Ferrante, Luigi

    2005-01-01

    Parasagittal meningiomas (PSM) may pose a difficult surgical challenge since venous patency and collateral anastomoses have to be clearly defined for correct surgical planning. The aim of this study was to assess the diagnostic value of contrast-enhanced (CE) magnetic resonance venography (MRV) in the preoperative evaluation of venous infiltration and collateral venous anastomoses in patients with PSM. CE-MRV was compared with phase-contrast (PC) magnetic resonance (MR) angiography, conventional angiography (when available), and surgery as a reference. Twenty-three patients undergoing surgery for meningiomas located adjacent to the superior sagittal sinus were prospectively evaluated. All the patients underwent both conventional MR examination and MRV. This was performed by means of PC and CE techniques. Both sets of angiograms (CE and PC) were evaluated by two expert neuroradiologists to assess (1) patency of the sinus (patent/occluded), (2) the extent of occlusion (in centimeters), and (3) the number of collateral anastomoses close to the insertion of the meningioma. Eight patients underwent digital subtraction angiography (DSA). All patients were operated on, and intraoperative findings were taken as the gold standard to evaluate the diagnostic value of MRA techniques. PC-MRV showed a flow void inside the sinus compatible with its occlusion in 15 cases, whereas CE-MRV showed the sinus to be occluded in five cases. CE-MRV data were confirmed by surgery, showing five patients to have an occlusion of the superior sagittal sinus. The PC-MRV sensitivity was thus 100% with a specificity of 50%. In those cases in which both MRV techniques documented occlusion of the sinus, the extent of occlusion was overestimated by PC compared with CE and surgery. CE-MRV depicted 87% of collateral venous anastomoses close to the meningioma as subsequently confirmed by surgery, while PC showed 58%. In the preoperative planning for patients with meningiomas located close to a venous

  3. Differentiating between Central Nervous System Lymphoma and High-grade Glioma Using Dynamic Susceptibility Contrast and Dynamic Contrast-enhanced MR Imaging with Histogram Analysis.

    Science.gov (United States)

    Murayama, Kazuhiro; Nishiyama, Yuya; Hirose, Yuichi; Abe, Masato; Ohyu, Shigeharu; Ninomiya, Ayako; Fukuba, Takashi; Katada, Kazuhiro; Toyama, Hiroshi

    2018-01-10

    We evaluated the diagnostic performance of histogram analysis of data from a combination of dynamic susceptibility contrast (DSC)-MRI and dynamic contrast-enhanced (DCE)-MRI for quantitative differentiation between central nervous system lymphoma (CNSL) and high-grade glioma (HGG), with the aim of identifying useful perfusion parameters as objective radiological markers for differentiating between them. Eight lesions with CNSLs and 15 with HGGs who underwent MRI examination, including DCE and DSC-MRI, were enrolled in our retrospective study. DSC-MRI provides a corrected cerebral blood volume (cCBV), and DCE-MRI provides a volume transfer coefficient (K trans ) for transfer from plasma to the extravascular extracellular space. K trans and cCBV were measured from a round region-of-interest in the slice of maximum size on the contrast-enhanced lesion. The differences in t values between CNSL and HGG for determining the most appropriate percentile of K trans and cCBV were investigated. The differences in K trans , cCBV, and K trans /cCBV between CNSL and HGG were investigated using histogram analysis. Receiver operating characteristic (ROC) analysis of K trans , cCBV, and K trans /cCBV ratio was performed. The 30 th percentile (C30) in K trans and 80 th percentile (C80) in cCBV were the most appropriate percentiles for distinguishing between CNSL and HGG from the differences in t values. CNSL showed significantly lower C80 cCBV, significantly higher C30 K trans , and significantly higher C30 K trans /C80 cCBV than those of HGG. In ROC analysis, C30 K trans /C80 cCBV had the best discriminative value for differentiating between CNSL and HGG as compared to C30 K trans or C80 cCBV. The combination of K trans by DCE-MRI and cCBV by DSC-MRI was found to reveal the characteristics of vascularity and permeability of a lesion more precisely than either K trans or cCBV alone. Histogram analysis of these vascular microenvironments enabled quantitative differentiation between

  4. Local Contrast Enhancement Using Intuitionistic Fuzzy Sets Optimized By Artificial Bee Colony Algorithm

    Directory of Open Access Journals (Sweden)

    Daniel M. Wonohadidjojo

    2017-03-01

    was applied. The results of local contrast enhancement using both methods were compared with the results using histogram equalization method. The tests were conducted using two MDCK cell images. The results of local contrast enhancement using both methods were evaluated by observing the enhanced images and IEM values. The results show that the methods outperform the histogram equalization method. Furthermore, the method using IFSABC is better than the IFS method.

  5. Segmentation methods for breast vasculature in dual-energy contrast-enhanced digital breast tomosynthesis

    Science.gov (United States)

    Lau, Kristen C.; Lee, Hyo Min; Singh, Tanushriya; Maidment, Andrew D. A.

    2015-03-01

    Dual-energy contrast-enhanced digital breast tomosynthesis (DE CE-DBT) uses an iodinated contrast agent to image the three-dimensional breast vasculature. The University of Pennsylvania has an ongoing DE CE-DBT clinical study in patients with known breast cancers. The breast is compressed continuously and imaged at four time points (1 pre-contrast; 3 post-contrast). DE images are obtained by a weighted logarithmic subtraction of the high-energy (HE) and low-energy (LE) image pairs. Temporal subtraction of the post-contrast DE images from the pre-contrast DE image is performed to analyze iodine uptake. Our previous work investigated image registration methods to correct for patient motion, enhancing the evaluation of vascular kinetics. In this project we investigate a segmentation algorithm which identifies blood vessels in the breast from our temporal DE subtraction images. Anisotropic diffusion filtering, Gabor filtering, and morphological filtering are used for the enhancement of vessel features. Vessel labeling methods are then used to distinguish vessel and background features successfully. Statistical and clinical evaluations of segmentation accuracy in DE-CBT images are ongoing.

  6. A prolapsed cervical disc with diffuse contrast enhancement on CT

    International Nuclear Information System (INIS)

    Goto, Jun; Shinpo, Tomoyuki; Inoue, Kiyoharu; Shigeno, Taku; Ochiai, Chikayuki

    1985-01-01

    A 48-year-old woman with the C5/6 disc herniation was reported. She had noticed vague pains in the left shoulder a half year earlier. Neurological examination showed left lower cervical radicular pains and incomplete Brown-Sequard syndrome of the same side. The disc herniation was diagnosed by myelography and discography. On the CT examination, surprisingly, the prolapsed disc was homogenously enhanced after the administration of intravenous contrast medium. The vertebral angiography showed increased vascularity behind the C5/6 intervertebral space. At operation, a prolapsed nucleus pulposus with proliferated connective tissue was found and curetted. The etiology of contrast enhancement was discussed. (author)

  7. Contrast-enhanced Ultrasound for Non-tumor Liver Diseases

    Directory of Open Access Journals (Sweden)

    H Maruyama

    2012-03-01

    Full Text Available Contrast-enhanced ultrasound (CEUS is a simple, safe and reliable technique for the clinical management of patients with various liver diseases. Although the major target of the technique may be focal hepatic lesions, it is also effective for the diagnosis of non-tumor liver diseases, such as grading hepatic fibrosis, characterization of chronic liver diseases and diagnosis of portal vein thrombosis. This review article aimed to overview the recent application of CEUS in the assessment of non-tumor liver diseases. Keywords: Cirrhosis, contrast agent, fibrosis, idiopathic portal hypertension, microbubble, portal vein thrombosis, ultrasound.

  8. Tolerance of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis

    Science.gov (United States)

    Rianti, R. A.; Priaminiarti, M.; Syahraini, S. I.

    2017-08-01

    Image enhancement brightness and contrast can be adjusted on lateral cephalometric digital radiographs to improve image quality and anatomic landmarks for measurement by Steiner analysis. To determine the limit value for adjustments of image enhancement brightness and contrast in lateral cephalometric digital radiography for Steiner analysis. Image enhancement brightness and contrast were adjusted on 100 lateral cephalometric radiography in 10-point increments (-30, -20, -10, 0, +10, +20, +30). Steiner analysis measurements were then performed by two observers. Reliabilities were tested by the Interclass Correlation Coefficient (ICC) and significance tested by ANOVA or the Kruskal Wallis test. No significant differences were detected in lateral cephalometric analysis measurements following adjustment of the image enhancement brightness and contrast. The limit value of adjustments of the image enhancement brightness and contrast associated with incremental 10-point changes (-30, -20, -10, 0, +10, +20, +30) does not affect the results of Steiner analysis.

  9. Initial staging of Hodgkin's disease: role of contrast-enhanced 18F FDG PET/CT.

    Science.gov (United States)

    Chiaravalloti, Agostino; Danieli, Roberta; Caracciolo, Cristiana Ragano; Travascio, Laura; Cantonetti, Maria; Gallamini, Andrea; Guazzaroni, Manlio; Orlacchio, Antonio; Simonetti, Giovanni; Schillaci, Orazio

    2014-08-01

    The objective of this study was to compare the diagnostic accuracy of positron emission tomography/low-dose computed tomography (PET/ldCT) versus the same technique implemented by contrast-enhanced computed tomography (ceCT) in staging Hodgkin's disease (HD).Forty patients (18 men and 22 women, mean age 30 ± 9.6) with biopsy-proven HD underwent a PET/ldCT study for initial staging including an unenhanced low-dose computed tomography for attenuation correction with positron emission tomography acquisition and a ceCT, performed at the end of the PET/ldCT scan, in the same exam session. A detailed datasheet was generated for illness locations for separate imaging modality comparison and then merged in order to compare the separate imaging method results (PET/ldCT and ceCT) versus merged results positron emission tomography/contrast-enhanced computed tomography (PET/ceCT). The nodal and extranodal lesions detected by each technique were then compared with follow-up data that served as the reference standard.No significant differences were found at staging between PET/ldCT and PET/ceCT in our series. One hundred and eighty four stations of nodal involvement have been found with no differences in both modalities. Extranodal involvement was identified in 26 sites by PET/ldCT and in 28 by PET/ceCT. We did not find significant differences concerning the stage (Ann Arbor).Our study shows a good concordance and conjunction between PET/ldCT and ceCT in both nodal and extranodal sites in the initial staging of HD, suggesting that PET/ldCT could suffice in most of these patients.

  10. Contrast-enhanced spectral mammography versus MRI: Initial results in the detection of breast cancer and assessment of tumour size.

    Science.gov (United States)

    Fallenberg, E M; Dromain, C; Diekmann, F; Engelken, F; Krohn, M; Singh, J M; Ingold-Heppner, B; Winzer, K J; Bick, U; Renz, D M

    2014-01-01

    To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard. After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation. Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology. Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography (CESM) is slowly being introduced into clinical practice. • Access to breast MRI is limited by availability and lack of reimbursement. • Initial results show a better sensitivity of CESM and MRI than conventional mammography. • CESM showed a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography offers promise, seemingly providing information comparable to MRI.

  11. Contrast-enhanced MR 3D angiography in the assessment of brain AVMs

    International Nuclear Information System (INIS)

    Unlu, Ercument; Temizoz, Osman; Albayram, Sait; Genchellac, Hakan; Hamamcioglu, M. Kemal; Kurt, Imran; Demir, M. Kemal

    2006-01-01

    Background and purpose: Digital subtraction angiography (DSA) is the current reference standard for the diagnosis, assessment, and management of brain arteriovenous malformations (AVMs). The purpose of this study was to compare the diagnostic utility of three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) and contrast-enhanced 3D MRA in patients with intracranial arteriovenous malformations (AVMs) in different sizes and locations. The AVM diagnosis was proved via DSA and almost half of the patients had also hematoma. Materials and methods: Two radiologists, experienced on neurovascular imaging and independent from each other, retrospectively reviewed two MRA techniques and DSA with regard to the assessment of feeding arteries, AVM nidus, and venous drainage patterns on 20 patients with 23 examinations by scoring system. Disagreements were resolved by consensus. Results: An excellent agreement between contrast-enhanced MRA and DSA was found in order to assess the numbers of arterial feeders and draining veins (Spearman r = 0.913, P < 0.001). The average scores in contrast-enhanced MRA for feeders, nidi, and drainers were respectively 2.26, 2.69, and 2.48, while in TOF-MRA they are 1.96, 1.35, and 0.89, respectively. Conclusion: Compared to TOF-MRA, 3D contrast-enhanced MRA is useful for visualization by subtraction technique of malformation components presented by hematoma or by haem product. On the other hand, for the cases presented by slow or complex flow that is especially in around or nidi or around the venous portion is also advantageous because of the independence from flow-related enhancement. Therapeutic effects were clearly demonstrated in three follow-up patients. A major limitation of this technique is the low spatial resolution. Since there is such a limitation, arterial feeder of a case with micro-AVM is not detected by contrast-enhanced MRA and nidus for the same case was observed retrospectively. In this respect, we

  12. Contrast-enhanced MR 3D angiography in the assessment of brain AVMs

    Energy Technology Data Exchange (ETDEWEB)

    Unlu, Ercument [Department of Radiology, Trakya University Medicine School, Edirne (Turkey)]. E-mail: drercument@yahoo.com; Temizoz, Osman [Department of Radiology, Trakya University Medicine School, Edirne (Turkey); Albayram, Sait [Department of Radiology, Istanbul University, Cerrahpasa Medicine School, Istanbul (Turkey); Genchellac, Hakan [Department of Radiology, Trakya University Medicine School, Edirne (Turkey); Hamamcioglu, M. Kemal [Department of Neurosurgery, Trakya University Medicine School, Edirne (Turkey); Kurt, Imran [Department of Biostatistics, Trakya University Medicine School, Edirne (Turkey); Demir, M. Kemal [Department of Radiology, Trakya University Medicine School, Edirne (Turkey)

    2006-12-15

    Background and purpose: Digital subtraction angiography (DSA) is the current reference standard for the diagnosis, assessment, and management of brain arteriovenous malformations (AVMs). The purpose of this study was to compare the diagnostic utility of three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) and contrast-enhanced 3D MRA in patients with intracranial arteriovenous malformations (AVMs) in different sizes and locations. The AVM diagnosis was proved via DSA and almost half of the patients had also hematoma. Materials and methods: Two radiologists, experienced on neurovascular imaging and independent from each other, retrospectively reviewed two MRA techniques and DSA with regard to the assessment of feeding arteries, AVM nidus, and venous drainage patterns on 20 patients with 23 examinations by scoring system. Disagreements were resolved by consensus. Results: An excellent agreement between contrast-enhanced MRA and DSA was found in order to assess the numbers of arterial feeders and draining veins (Spearman r = 0.913, P < 0.001). The average scores in contrast-enhanced MRA for feeders, nidi, and drainers were respectively 2.26, 2.69, and 2.48, while in TOF-MRA they are 1.96, 1.35, and 0.89, respectively. Conclusion: Compared to TOF-MRA, 3D contrast-enhanced MRA is useful for visualization by subtraction technique of malformation components presented by hematoma or by haem product. On the other hand, for the cases presented by slow or complex flow that is especially in around or nidi or around the venous portion is also advantageous because of the independence from flow-related enhancement. Therapeutic effects were clearly demonstrated in three follow-up patients. A major limitation of this technique is the low spatial resolution. Since there is such a limitation, arterial feeder of a case with micro-AVM is not detected by contrast-enhanced MRA and nidus for the same case was observed retrospectively. In this respect, we

  13. Quantitative dynamic contrast-enhanced MR imaging analysis of complex adnexal masses: a preliminary study

    International Nuclear Information System (INIS)

    Thomassin-Naggara, Isabelle; Balvay, Daniel; Aubert, Emilie; Bazot, Marc; Darai, Emile; Rouzier, Roman; Cuenod, Charles A.

    2012-01-01

    To evaluate the ability of quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to differentiate malignant from benign adnexal tumours. Fifty-six women with 38 malignant and 18 benign tumours underwent MR imaging before surgery for complex adnexal masses. Microvascular parameters were extracted from high temporal resolution DCE-MRI series, using a pharmacokinetic model in the solid tissue of adnexal tumours. These parameters were tissue blood flow (F T ), blood volume fraction (Vb), permeability-surface area product (PS), interstitial volume fraction (Ve), lag time (Dt) and area under the enhancing curve (rAUC). Area under the receiver operating curve (AUROC) was calculated as a descriptive tool to assess the overall discrimination of parameters. Malignant tumours displayed higher F T , Vb, rAUC and lower Ve than benign tumours (P T was the most relevant factor for discriminating malignant from benign tumours (AUROC = 0.86). Primary ovarian invasive tumours displayed higher F T and shorter Dt than borderline tumours. Malignant adnexal tumours with associated peritoneal carcinomatosis at surgery displayed a shorter Dt than those without peritoneal carcinomatosis at surgery (P = 0.01). Quantitative DCE-MRI is a feasible and accurate technique to differentiate malignant from benign adnexal tumours and could potentially help oncologists with management decisions. (orig.)

  14. Anemia and the risk of contrast-induced nephropathy in patients with renal insufficiency undergoing contrast-enhanced MDCT

    International Nuclear Information System (INIS)

    Murakami, Ryusuke; Kumita, Shin-ichiro; Hayashi, Hiromitsu; Sugizaki, Ken-ichi; Okazaki, Emi; Kiriyama, Tomonari; Hakozaki, Kenta; Tani, Hitomi; Miki, Izumi; Takeda, Minako

    2013-01-01

    Purpose: The purpose of this study was to assess the effect of anemia on the incidence of contrast-induced nephropathy (CIN) in patients with renal impairment undergoing MDCT. Materials and methods: Institutional review board approval was waived for this retrospective review of 843 patients with stable renal insufficiency (eGFR between 15 and 60 mL/min) who had undergone contrast-enhanced MDCT. Baseline hematocrit and hemoglobin values were measured. Serum creatinine (SCr) was assessed at the baseline and at 48–72 h after contrast administration. Results: The overall incidence of CIN in the patient population with renal insufficiency was 6.9%. CIN developed in 7.8% (54 of 695) of anemic patients, and in 2.8% (4 of 148) of non-anemic patients (P = .027). After adjustment for confounders, low hemoglobin and low hematocrit values remained independent predictors of CIN (odds ratio 4.6, 95% CI 1.0–20.5, P = .046). Conclusions: Anemia is associated with a higher incidence of CIN in patients with renal insufficiency. Anemia is a potentially modifiable risk factor for CIN, and has an unfavorable impact on prognosis in patients with renal insufficiency undergoing contrast-enhanced MDCT

  15. Anemia and the risk of contrast-induced nephropathy in patients with renal insufficiency undergoing contrast-enhanced MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Murakami, Ryusuke, E-mail: rywakana@nms.ac.jp; Kumita, Shin-ichiro; Hayashi, Hiromitsu; Sugizaki, Ken-ichi; Okazaki, Emi; Kiriyama, Tomonari; Hakozaki, Kenta; Tani, Hitomi; Miki, Izumi; Takeda, Minako

    2013-10-01

    Purpose: The purpose of this study was to assess the effect of anemia on the incidence of contrast-induced nephropathy (CIN) in patients with renal impairment undergoing MDCT. Materials and methods: Institutional review board approval was waived for this retrospective review of 843 patients with stable renal insufficiency (eGFR between 15 and 60 mL/min) who had undergone contrast-enhanced MDCT. Baseline hematocrit and hemoglobin values were measured. Serum creatinine (SCr) was assessed at the baseline and at 48–72 h after contrast administration. Results: The overall incidence of CIN in the patient population with renal insufficiency was 6.9%. CIN developed in 7.8% (54 of 695) of anemic patients, and in 2.8% (4 of 148) of non-anemic patients (P = .027). After adjustment for confounders, low hemoglobin and low hematocrit values remained independent predictors of CIN (odds ratio 4.6, 95% CI 1.0–20.5, P = .046). Conclusions: Anemia is associated with a higher incidence of CIN in patients with renal insufficiency. Anemia is a potentially modifiable risk factor for CIN, and has an unfavorable impact on prognosis in patients with renal insufficiency undergoing contrast-enhanced MDCT.

  16. Leptomeningeal contrast enhancement in moyamoya: its potential role in postoperative assessment of circulation through the bypass

    International Nuclear Information System (INIS)

    Komiyama, M.; Nakajima, H.; Nishikawa, M.; Yasui, T.; Kitano, S.; Sakamoto, H.

    2001-01-01

    Leptomeningeal contrast enhancement (LMCE) is one of the MRI features of moyamoya. Its clinical significance, however, is not elucidated. Our purpose was to characterise LMCE on MRI and to evaluate its role in the assessment of circulation through a surgically established bypass in moyamoya. We studied 16 patients with idiopathic moyamoya (seven males, nine females, includingt four children, aged 7 to 54 years, mean 24 years) who underwent T1-weighted MRI before and after intravenous contrast medium. The presence of LMCE, its intensity and anatomical distribution, catheter angiographic findings, and relation of LMCE to the bypass surgery were assessed. More LMCE was seen in the cerebrum in most patients with moyamoya than in normal controls. LMCE in the brain stem and cerebellum was minimal, similar to that seen in the controls. LMCE was less prominent following surgery than before operation or in patients who did not undergo surgery. In three patients examined both before and after operation LMCE became less prominent following bypass surgery. As LMCE becomes less prominent after ''effective'' bypass surgery, this may be used for evaluation of effectiveness of surgery in moyamoya. (orig.)

  17. Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications

    International Nuclear Information System (INIS)

    Reimer, Peter; Schneider, Guenter; Schima, Wolfgang

    2004-01-01

    Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd-EOB-DTPA, is under consideration. The purpose of this review is to provide an overview on the properties, clinical development and application of these three hepatobiliary contrast agents. Bolus injectable paramagnetic hepatobiliary contrast agents combine established features of extracellular agents with the advantages of hepatocyte specificity. The detection and characterisation of focal liver disease appears to be improved compared to unenhanced MRI, MRI with unspecific contrast agents and contrast-enhanced CT. To decrease the total time spent by a patient in the MR scanner, it is advisable to administer the agent immediately after acquisition of unenhanced T1-w MRI. After infusion or bolus injection (with dynamic FS-T1-w 2D or 3D GRE) of the contrast agent, moderately and heavily T2w images are acquired. Post-contrast T1-w MRI is started upon completion of T2-w MRI for mangafodipir trisodium and Gd-EOB-DTPA as early as 20 min following injection, while gadobenate dimeglumine scans are obtained >60 min following injection. Post-contrast acquisition techniques with near isotropic 3D pulse sequences with fat saturation parallel the technical progress made by MSCT combined with an unparalleled improvement in tumour-liver contrast. The individual decision that hepatobiliary contrast agent one uses is partly based on personal preferences. No comparative studies have been conducted comparing the advantages or disadvantages of all three agents directly against each other. (orig.)

  18. Brain tumours at 7T MRI compared to 3T - contrast effect after half and full standard contrast agent dose: initial results

    International Nuclear Information System (INIS)

    Noebauer-Huhmann, Iris-Melanie; Weber, M.; Szomolanyi, P.; Juras, V.; Kronnerwetter, C.; Widhalm, G.; Nemec, S.; Prayer, D.; Ladd, M.E.; Trattnig, S.

    2015-01-01

    To compare the contrast agent effect of a full dose and half the dose of gadobenate dimeglumine in brain tumours at 7 Tesla (7T) MR versus 3 Tesla (3T). Ten patients with primary brain tumours or metastases were examined. Signal intensities were assessed in the lesion and normal brain. Tumour-to-brain contrast and lesion enhancement were calculated. Additionally, two independent readers subjectively graded the image quality and artefacts. The enhanced mean tumour-to-brain contrast and lesion enhancement were significantly higher at 7T than at 3T for both half the dose (91.8 ± 45.8 vs. 43.9 ± 25.3 [p = 0.010], 128.1 ± 53.7 vs. 75.5 ± 32.4 [p = 0.004]) and the full dose (129.2 ± 50.9 vs. 66.6 ± 33.1 [p = 0.002], 165.4 ± 54.2 vs. 102.6 ± 45.4 [p = 0.004]). Differences between dosages at each field strength were also significant. Lesion enhancement was higher with half the dose at 7T than with the full dose at 3T (p =.037), while the tumour-to-brain contrast was not significantly different. Subjectively, contrast enhancement, visibility, and lesion delineation were better at 7T and with the full dose. All parameters were rated as good, at the least. Half the routine contrast agent dose at 7T provided higher lesion enhancement than the full dose at 3T which indicates the possibility of dose reduction at 7T. (orig.)

  19. Brain tumours at 7T MRI compared to 3T - contrast effect after half and full standard contrast agent dose: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Noebauer-Huhmann, Iris-Melanie; Weber, M. [Medical University of Vienna, High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Medical University of Vienna, Division of Neuroradiology and Musculoskeletal Radiology, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Szomolanyi, P.; Juras, V. [Medical University of Vienna, High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Slovak Academy of Sciences, Department of Imaging Methods, Institute of Measurement Science, Bratislava (Slovakia); Kronnerwetter, C. [Medical University of Vienna, High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Widhalm, G. [Medical University of Vienna, Department of Neurosurgery, Vienna (Austria); Nemec, S.; Prayer, D. [Medical University of Vienna, Division of Neuroradiology and Musculoskeletal Radiology, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ladd, M.E. [University Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); German Cancer Research Center (DKFZ), Division of Medical Physics in Radiology, Heidelberg (Germany); Trattnig, S. [Medical University of Vienna, High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Austrian Cluster for Tissue Regeneration, Vienna (Austria)

    2015-01-15

    To compare the contrast agent effect of a full dose and half the dose of gadobenate dimeglumine in brain tumours at 7 Tesla (7T) MR versus 3 Tesla (3T). Ten patients with primary brain tumours or metastases were examined. Signal intensities were assessed in the lesion and normal brain. Tumour-to-brain contrast and lesion enhancement were calculated. Additionally, two independent readers subjectively graded the image quality and artefacts. The enhanced mean tumour-to-brain contrast and lesion enhancement were significantly higher at 7T than at 3T for both half the dose (91.8 ± 45.8 vs. 43.9 ± 25.3 [p = 0.010], 128.1 ± 53.7 vs. 75.5 ± 32.4 [p = 0.004]) and the full dose (129.2 ± 50.9 vs. 66.6 ± 33.1 [p = 0.002], 165.4 ± 54.2 vs. 102.6 ± 45.4 [p = 0.004]). Differences between dosages at each field strength were also significant. Lesion enhancement was higher with half the dose at 7T than with the full dose at 3T (p =.037), while the tumour-to-brain contrast was not significantly different. Subjectively, contrast enhancement, visibility, and lesion delineation were better at 7T and with the full dose. All parameters were rated as good, at the least. Half the routine contrast agent dose at 7T provided higher lesion enhancement than the full dose at 3T which indicates the possibility of dose reduction at 7T. (orig.)

  20. THE EXPERIENCE OF USING ULTRASOUND WITH CONTRAST ENHANCEMENT IN THE DIAGNOSIS OF CERVICAL CANCER

    Directory of Open Access Journals (Sweden)

    M. A. Chekalova

    2017-01-01

    Full Text Available The purpose of the study was to evaluate the value of contrast-enhanced ultrasound in detecting local spread, regional and distant metastases from cervical cancer. Materials and methods. The findings of contrast-enhanced ultrasound examination of 4 cervical cancer patients (IB1–IVB treated at N.N. Blokhin Russian Cancer Research Center from September to October 2016 were evaluated. The HI VISION Ascendus device was used. Ultrasound patterns in different phases of contrast-enhanced accumulation and excretion were analyzed. Results. Our first experience in using contrast-enhanced ultrasound in the detection of local spread, regional and distant metastases from cervical cancer allowed us to study the structure of the tumor and its spread in greater detail. Conclusion. A small number of observations do not yet allow us to draw serious conclusions about the capabilities of this modern technology. 

  1. Value of contrast enhanced CT scanning in the non-trauma emergency room patient

    International Nuclear Information System (INIS)

    Wood, L.P.; Parisi, M.; Finch, I.J.

    1990-01-01

    To determine the value of performing contrast CT in addition to non-contrast CT in the evaluation of acute non-traumatic central nervous system disorders, we retrospectively reviewed 322 cases originating from the emergency room at our institution. The most common indication for scanning was seizure activity (34% of total), followed by headache (30%), focal neurological deficit (10%), and altered mental status (8%). 75% of the noncontrast scans were normal. The contrast enhanced scan revealed abnormalities not evident on the non-contrast scan in only three of these cases, and the information did not alter patient management. We conclude that in the acute setting, if a non-contrast CT is normal, a contrast study is usually unnecessary. Therefore, given the additional risks of contrast infusion, the contrast study, if needed, is generally best obtained at a later date, after more careful evaluation of the patient's history and medical records. If the non-contrast CT scan is abnormal, a contrast enhanced CT scan may be beneficial, but, again, is often not needed to direct acute patient management. (orig.)

  2. Comparison of gadolinium polylysine and gadopentetate in contrast enhanced MR imaging of myocardial ischemia-reperfusion in cats

    International Nuclear Information System (INIS)

    Lim, Tae Hwan; Lee, Jung Hee; Lee, Tae Keun; Mun, Chi Woong

    1995-01-01

    To assess the signal enhancement by gadolinium-DTPA-polylysine (Gd-polylysine) as compared to gadopentetate (Gd-DTPA) in MR imaging of heart that have undergone ischemia-reperfusion, and to estimate the extent of myocardial damage covered by the MR signal enhancement. A series of contrast enhanced cardiac MR images were obtained from 17 cats subjected to a 90 minutes of occlusion of the left anterior descending coronary artery (LAD) followed by a 90 minutes of reperfusion. Time courses of changes in the signal intensity (SI) of the ischemic area were measured in Gd-polylysine group (8 cats) and Gd-DTPA group (9 cats). The size of MR signal enhanced area was then compared to the sizes of infarction and the area at risk revealed by TTC histochemical staining. Maximum SIs were obtained at 60 minutes and 30 minutes after injection of the contrast material, respectively for Gd-polylysine group and Gd-DTPA group. Signal enhancement was stronger and persistent for a longer period in Gd-polylysine group than in GD-DTPA group. Sizes of the enhanced are, the infarction, and the area at risk were about 30%, 15%, and 50% of the total left ventricle (LV) area; the difference between the groups was statistically insignificant. Gd-polylysine can be used better for a blood pool marker than Gd-DTPA in MR imaging of myocardial ischemia, due to its strong and persistent signal enhancement. The MR signal enhanced area includes both the infarcted area and a portion of the area at risk

  3. Contrast-enhanced ultrasound in the diagnosis of nodules in liver cirrhosis.

    Science.gov (United States)

    Kim, Tae Kyoung; Jang, Hyun-Jung

    2014-04-07

    Contrast-enhanced ultrasound (CEUS) using microbubble contrast agents are useful for the diagnosis of the nodules in liver cirrhosis. CEUS can be used as a problem-solving method for indeterminate nodules on computed tomography (CT) or magnetic resonance imaging (MRI) or as an initial diagnostic test for small newly detected liver nodules. CEUS has unique advantages over CT and MRI including no renal excretion of contrast, real-time imaging capability, and purely intravascular contrast. Hepatocellular carcinoma (HCC) is characterized by arterial-phase hypervascularity and later washout (negative enhancement). Benign nodules such as regenerative nodules or dysplastic nodules are usually isoechoic or slightly hypoechoic in the arterial phase and isoechoic in the late phase. However, there are occasional HCC lesions with atypical enhancement including hypovascular HCC and hypervascular HCC without washout. Cholangiocarcinomas are infrequently detected during HCC surveillance and mostly show rim-like or diffuse hypervascularity followed by rapid washout. Hemangiomas are often found at HCC surveillance and are easily diagnosed by CEUS. CEUS can be effectively used in the diagnostic work-up of small nodules detected at HCC surveillance. CEUS is also useful to differentiate malignant and benign venous thrombosis and to guide and monitor the local ablation therapy for HCC.

  4. Fat-saturated, contrast-enhanced spin echo sequences in magnetic resonance tomographic diagnosis of peritoneal carcinosis

    International Nuclear Information System (INIS)

    Ricke, J.; Hosten, N.; Stroszczynski, C.; Amthauer, H.; Felix, R.; Sehouli, J.; Buchmann, E.; Rieger, J.

    1999-01-01

    Purpose: To evaluate contrast-enhanced, fat-saturated spin echo sequences for the detection of peritoneal carcinosis with MRI. Material and Methods: 61 patients, 35 with and 26 without peritoneal carcinosis, were examined with abdominal MRI. Fat-saturated, T 1 -weighted spin echo sequences were performed before and after administration of Gd-DTPA. In addition, 22 patients with peritoneal carcinosis were examined with contrast-enhanced abdominal CT. Results: 32 of 35 patients with peritoneal carcinosis demonstrated contrast enhancement of the visceral and 30 to 35 enhancement of the parietal peritoneum (91 and 86%, respectively). Wall thickening of the intestine or parietal peritoneum were noted in 21 and 20 of 35 patients (60 and 57%, respectively), ascites in 18 of 35 patients (51%). False positive contrast enhancement of the peritoneum was noted in 4 of 26 patients (15%). In the direct comparison of MRI and CT, 22 of 22 patients versus 7 of 22 patients showed contrast enhancement of the visceral peritoneum (100 and 32%, respectively). For other signs of peritoneal carcinosis (e.g., ascites, peritoneal seedings), no differences in diagnostic reliability were demonstrated. Conclusions: The use of fat-saturated, spin echo sequences facilitates the diagnosis of peritoneal carcinosis by artifact reduction and improved detection of peritoneal contrast enhancement. MRI with fat-saturated sequences was superior to CT. (orig.) [de

  5. A Combined Pharmacokinetic and Radiologic Assessment of Dynamic Contrast-Enhanced Magnetic Resonance Imaging Predicts Response to Chemoradiation in Locally Advanced Cervical Cancer

    International Nuclear Information System (INIS)

    Semple, Scott; Harry, Vanessa N. MRCOG.; Parkin, David E.; Gilbert, Fiona J.

    2009-01-01

    Purpose: To investigate the combination of pharmacokinetic and radiologic assessment of dynamic contrast-enhanced magnetic resonance imaging (MRI) as an early response indicator in women receiving chemoradiation for advanced cervical cancer. Methods and Materials: Twenty women with locally advanced cervical cancer were included in a prospective cohort study. Dynamic contrast-enhanced MRI was carried out before chemoradiation, after 2 weeks of therapy, and at the conclusion of therapy using a 1.5-T MRI scanner. Radiologic assessment of uptake parameters was obtained from resultant intensity curves. Pharmacokinetic analysis using a multicompartment model was also performed. General linear modeling was used to combine radiologic and pharmacokinetic parameters and correlated with eventual response as determined by change in MRI tumor size and conventional clinical response. A subgroup of 11 women underwent repeat pretherapy MRI to test pharmacokinetic reproducibility. Results: Pretherapy radiologic parameters and pharmacokinetic K trans correlated with response (p < 0.01). General linear modeling demonstrated that a combination of radiologic and pharmacokinetic assessments before therapy was able to predict more than 88% of variance of response. Reproducibility of pharmacokinetic modeling was confirmed. Conclusions: A combination of radiologic assessment with pharmacokinetic modeling applied to dynamic MRI before the start of chemoradiation improves the predictive power of either by more than 20%. The potential improvements in therapy response prediction using this type of combined analysis of dynamic contrast-enhanced MRI may aid in the development of more individualized, effective therapy regimens for this patient group.

  6. Dynamic contrast-enhanced MRI evaluation of cerebral cavernous malformations.

    Science.gov (United States)

    Hart, Blaine L; Taheri, Saeid; Rosenberg, Gary A; Morrison, Leslie A

    2013-10-01

    The aim of this study is to quantitatively evaluate the behavior of CNS cavernous malformations (CCMs) using a dynamic contrast-enhanced MRI (DCEMRI) technique sensitive for slow transfer rates of gadolinium. The prospective study was approved by the institutional review board and was HIPPA compliant. Written informed consent was obtained from 14 subjects with familial CCMs (4 men and 10 women, ages 22-76 years, mean 48.1 years). Following routine anatomic MRI of the brain, DCEMRI was performed for six slices, using T1 mapping with partial inversion recovery (TAPIR) to calculate T1 values, following administration of 0.025 mmol/kg gadolinium DTPA. The transfer rate (Ki) was calculated using the Patlak model, and Ki within CCMs was compared to normal-appearing white matter as well as to 17 normal control subjects previously studied. All subjects had typical MRI appearance of CCMs. Thirty-nine CCMs were studied using DCEMRI. Ki was low or normal in 12 lesions and elevated from 1.4 to 12 times higher than background in the remaining 27 lesions. Ki ranged from 2.1E-6 to 9.63E-4 min(-1), mean 3.55E-4. Normal-appearing white matter in the CCM patients had a mean Ki of 1.57E-4, not statistically different from mean WM Ki of 1.47E-4 in controls. TAPIR-based DCEMRI technique permits quantifiable assessment of CCMs in vivo and reveals considerable differences not seen with conventional MRI. Potential applications include correlation with biologic behavior such as lesion growth or hemorrage, and measurement of drug effects.

  7. Diagnostic performance of fluorodeoxyglucose-positron emission tomography/computed tomography of breast cancer in detecting axillary lymph node metastasis. Comparison with ultrasonography and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Monzawa, Shuichi; Adachi, Shuji; Suzuki, Kayo; Hirokaga, Koichi; Takao, Shintaro; Sakuma, Toshiko; Hanioka, Keisuke

    2009-01-01

    The purpose of this retrospective study was to evaluate the diagnostic performance of positron emission tomography/computed tomography (PET/CT) with fluorine-18-labeled 2-fluoro-2-deoxy-D-glucose (FDG) in comparison with that of ultrasonography and contrast-enhanced computed tomography (CT) in detecting axillary lymph node metastasis in patients with breast cancer. Fifty patients with invasive breast cancer were recruited. They had received no neoadjuvant chemotherapy and underwent PET/CT, ultrasonography and contrast-enhanced CT before mastectomy. The clinical stage was I in 34 patients, II in 15 patients, and III in one patient. The images of these modalities were interpreted in usual practice before surgery and the diagnostic reports were reviewed for analysis. Sensitivity, specificity, positive predictive value, and negative predictive value of each modality were obtained taking histopathological results of axillary lymph node dissection or sentinel lymph node biopsy as the reference standard. Axillary lymph node metastasis was confirmed in 15 of 50 patients by histopathological studies. PET/CT identified lymph node metastasis in three of these 15 patients. The overall sensitivity and specificity, positive predictive value, and negative predictive value of PET/CT in the diagnosis of axillary lymph node metastasis were 20, 97, 75, and 74%, and those of ultrasonography were 33, 94, 71, and 77% and those of contrast-enhanced CT were 27, 97, 80, and 76%, respectively. PET/CT showed poor sensitivity and high specificity in the detection of axillary lymph node metastasis of breast cancer. Diagnostic performance of PET/CT was not superior to that of ultrasonography and contrast-enhanced CT. (author)

  8. Myocardial enhancement pattern in patients with acute myocardial infarction on two-phase contrast-enhanced Ecg-gated multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Ko, S.M.; Seo, J.B.; Hong, M.K.; Do, K.H.; Lee, S.H.; Lee, J.S.; Song, J.W.; Park, S.J.; Park, S.W.; Lim, T.H.

    2006-01-01

    Aim: To evaluate the myocardial enhancement pattern of the left ventricle on two-phase contrast-enhanced electrocardiogram (ECG)-gated multidetector computed tomography (MDCT) images in patients with acute myocardial infarction (AMI). METHODS: Two-phase contrast-enhanced ECG-gated MDCT examinations were performed in 16 patients with AMI. The presence, location and pattern of myocardial enhancement were evaluated. MDCT findings were compared with the catheter angiographic results. RESULTS: Subendocardial (n=9) or transmural (n=6) area of early perfusion defects of the myocardium was detected in 15 of 16 patients (94%) on early-phase CT images. Variable delayed myocardial enhancement patterns on late-phase CT images were observed in 12 patients (75%): (1) subendocardial residual perfusion defect and subepicardial late enhancement (n=6); (2) transmural late enhancement (n=1); (3) isolated subendocardial late enhancement (n=1); and (4) isolated subendocardial residual perfusion defect (n=2). On catheter angiography, 14 of 15 corresponding coronary arteries showed significant stenosis. CONCLUSION: Variable abnormal myocardial enhancement pattern was seen on two-phase, contrast-enhanced ECG-gated MDCT in patients with AMI. Assessment of myocardial attenuation on CT angiography gives additional information of the location and extent of infarction

  9. Predicting IDH mutation status of intrahepatic cholangiocarcinomas based on contrast-enhanced CT features

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yong [Nanjing Drum Tower Hospital Clinical College of Traditional Chinese and Western Medicine, Nanjing University of Chinese Medicine, Department of Radiology, Nanjing, Jiangsu Province (China); Chen, Jun [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Pathology, Nanjing, Jiangsu Province (China); Kong, Weiwei [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Oncology, Nanjing, Jiangsu Province (China); Mao, Liang; Qiu, Yudong [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Hepatopancreatobiliary Surgery, Nanjing, Jiangsu Province (China); Kong, Wentao [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Ultrasonography, Nanjing, Jiangsu Province (China); Zhou, Qun [Nanjing Drum Tower Hospital Clinical College of Nanjing Medical University, Department of Radiology, Nanjing, Jiangsu Province (China); Zhou, Zhengyang; Zhu, Bin; He, Jian [Nanjing Drum Tower Hospital, the Affiliated Hospital of Nanjing University Medical School, Department of Radiology, Nanjing, Jiangsu Province (China); Wang, Zhongqiu [Jiangsu Province Hospital of Traditional Chinese Medicine, the Affiliated Hospital of Nanjing University of Chinese Medicine, Department of Radiology, Nanjing, Jiangsu Province (China)

    2018-01-15

    To explore the difference in contrast-enhanced computed tomography (CT) features of intrahepatic cholangiocarcinomas (ICCs) with different isocitrate dehydrogenase (IDH) mutation status. Clinicopathological and contrast-enhanced CT features of 78 patients with 78 ICCs were retrospectively analysed and compared based on IDH mutation status. There were 11 ICCs with IDH mutation (11/78, 14.1%) and 67 ICCs without IDH mutation (67/78, 85.9%). IDH-mutated ICCs showed intratumoral artery more often than IDH-wild ICCs (p = 0.023). Most ICCs with IDH mutation showed rim and internal enhancement (10/11, 90.9%), while ICCs without IDH mutation often appeared diffuse (26/67, 38.8%) or with no enhancement (4/67, 6.0%) in the arterial phase (p = 0.009). IDH-mutated ICCs showed significantly higher CT values, enhancement degrees and enhancement ratios in arterial and portal venous phases than IDH-wild ICCs (all p < 0.05). The CT value of tumours in the portal venous phase performed best in distinguishing ICCs with and without IDH mutation, with an area under the curve of 0.798 (p = 0.002). ICCs with and without IDH mutation differed significantly in arterial enhancement mode, and the tumour enhancement degree on multiphase contrast-enhanced CT was helpful in predicting IDH mutation status. (orig.)

  10. Synergistic enhancement of iron oxide nanoparticle and gadolinium for dual-contrast MRI

    International Nuclear Information System (INIS)

    Zhang, Fan; Huang, Xinglu; Qian, Chunqi; Zhu, Lei; Hida, Naoki; Niu, Gang; Chen, Xiaoyuan

    2012-01-01

    Highlights: ► MR contrast agents exert influence on T 1 or T 2 relaxation time of the surrounding tissue. ► Combined use of iron oxide and Gd-DTPA can improve the sensitivity/specificity of lesion detection. ► Dual contrast MRI enhances the delineation of tumor borders and small lesions. ► The effect of DC-MRI can come from the high paramagnetic susceptibility of Gd 3+ . ► The effect of DC-MRI can also come from the distinct pharmacokinetic distribution of SPIO and Gd-DTPA. -- Abstract: Purpose: The use of MR contrast agents allows accurate diagnosis by exerting an influence on the longitudinal (T 1 ) or transverse (T 2 ) relaxation time of the surrounding tissue. In this study, we combined the use of iron oxide (IO) particles and nonspecific extracellular gadolinium chelate (Gd) in order to further improve the sensitivity and specificity of lesion detection. Procedures: With a 7-Tesla scanner, pre-contrasted, IO-enhanced and dual contrast agent enhanced MRIs were performed in phantom, normal animals, and animal models of lymph node tumor metastases and orthotopic brain tumor. For the dual-contrast (DC) MRI, we focused on the evaluation of T 2 weighted DC MRI with IO administered first, then followed by the injection of a bolus of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA). Results: Based on the C/N ratios and MRI relaxometry, the synergistic effect of coordinated administration of Gd-DTPA and IO was observed and confirmed in phantom, normal liver and tumor models. At 30 min after administration of Feridex, Gd-DTPA further decreased T 2 relaxation in liver immediately after the injection. Additional administration of Gd-DTPA also immediately increased the signal contrast between tumor and brain parenchyma and maximized the C/N ratio to −4.12 ± 0.71. Dual contrast MRI also enhanced the delineation of tumor borders and small lesions. Conclusions: DC-MRI will be helpful to improve diagnostic accuracy and decrease the threshold size for

  11. Dynamic and delayed contrast enhancement in upper abdominal MRI studies: Comparison of gadoxetic acid and gadobutrol

    Energy Technology Data Exchange (ETDEWEB)

    Zizka, Jan [Department of Radiology, Charles University Hospital, Sokolska 581, CZ-500 05 Hradec Kralove (Czech Republic)]. E-mail: zizka@fnhk.cz; Klzo, Ludovit [Department of Radiology, Charles University Hospital, Sokolska 581, CZ-500 05 Hradec Kralove (Czech Republic); Ferda, Jiri [Department of Radiology, Charles University Hospital, Alej Svobody 80, CZ-306 40 Plzen (Czech Republic); Mrklovsky, Milan [Department of Radiology and Imaging Centre Pardubice, Regional Hospital, Kyjevska 44, CZ-530 01 Pardubice (Czech Republic); Bukac, Josef [Department of Biophysics, Medical Faculty, Charles University, Simkova 870, CZ-500 38 Hradec Kralove (Czech Republic)

    2007-05-15

    Objective: To prospectively compare contrast properties of extracelullar (gadobutrol) and hepatospecific (gadoxetic acid) contrast agents in upper abdominal MRI studies. Materials and methods: Standardized (0.1 ml/kg) dose of gadobutrol (56 subjects) and gadoxetic acid (51 subjects) was administered intravenously by MRI-compatible injector at 2 ml/s, followed by 20 ml saline flush. MR signal intensity changes (SIC) between precontrast scans and arterial phase, portal venous phase, equilibrium, and delayed scans at 10 and 20 min were measured in abdominal aorta, portal vein, common bile duct, liver, and spleen. Mean SIC values for gadobutrol and gadoxetic acid were compared by a two-sample t-test with p-value <0.05 considered significant. Results: In abdominal aorta, the mean SIC in the arterial phase did not significantly differ between gadobutrol (330%) and gadoxetic acid (295%). In portal vein, the mean SIC in the portal venous phase significantly differed between gadobutrol (267%) and gadoxetic acid (176%). Liver parenchyma enhancement was significantly higher for gadobutrol than for gadoxetic acid in both arterial phase (28 versus 13%) and portal venous phase (81 versus 46%). On the contrary, gadobutrol reached significantly lower mean SIC in the liver on delayed scans at 10 min (47 versus 59%) and 20 min (40 versus 67%), as well as in common bile duct at 10 min (54 versus 133%) and 20 min (57 versus 457%), respectively. In the spleen, mean SIC for gadobutrol was significantly higher at all phases. Conclusion: Gadobutrol showed superior enhancement of upper abdominal structures in the dynamic phases whereas gadoxetic acid showed better enhancement of the hepatobiliary structures on delayed scans.

  12. Automated Processing of Dynamic Contrast-Enhanced MRI: Correlation of Advanced Pharmacokinetic Metrics with Tumor Grade in Pediatric Brain Tumors.

    Science.gov (United States)

    Vajapeyam, S; Stamoulis, C; Ricci, K; Kieran, M; Poussaint, T Young

    2017-01-01

    Pharmacokinetic parameters from dynamic contrast-enhanced MR imaging have proved useful for differentiating brain tumor grades in adults. In this study, we retrospectively reviewed dynamic contrast-enhanced perfusion data from children with newly diagnosed brain tumors and analyzed the pharmacokinetic parameters correlating with tumor grade. Dynamic contrast-enhanced MR imaging data from 38 patients were analyzed by using commercially available software. Subjects were categorized into 2 groups based on pathologic analyses consisting of low-grade (World Health Organization I and II) and high-grade (World Health Organization III and IV) tumors. Pharmacokinetic parameters were compared between the 2 groups by using linear regression models. For parameters that were statistically distinct between the 2 groups, sensitivity and specificity were also estimated. Eighteen tumors were classified as low-grade, and 20, as high-grade. Transfer constant from the blood plasma into the extracellular extravascular space (K trans ), rate constant from extracellular extravascular space back into blood plasma (K ep ), and extracellular extravascular volume fraction (V e ) were all significantly correlated with tumor grade; high-grade tumors showed higher K trans , higher K ep , and lower V e . Although all 3 parameters had high specificity (range, 82%-100%), K ep had the highest specificity for both grades. Optimal sensitivity was achieved for V e , with a combined sensitivity of 76% (compared with 71% for K trans and K ep ). Pharmacokinetic parameters derived from dynamic contrast-enhanced MR imaging can effectively discriminate low- and high-grade pediatric brain tumors. © 2017 by American Journal of Neuroradiology.

  13. The value of contrast-enhanced CT scan in prediction of development of contusional hemorrhage

    International Nuclear Information System (INIS)

    Yokoyama, Kazuhiro; Kyoi, Kikuo; Sakaki, Toshisuke; Kinugawa, Kazuhiko; Morimoto, Tetsuya

    1983-01-01

    It is often experienced that even if there are no significant findings on the initial plain CT scan in the patient with cerebral contusion, the patient has thereafter a serious clinical course and requires emergency operation for so-called contusional hemorrhage. In order to predict of the development of contusional hemorrhage we performed contrast-enhanced CT scan at the time of patient's arrival within 12 hours after injury, if there was cerebral contusion on the initial plain CT scan, and repeated plain CT scan 24 hours after the contrast-enhanced CT scan. If enhancement was demonstrated on the contrastenhanced CT scan, we predicted the development of contusional hemorrhage and if not demonstrated, we predicted no more development of contusional hemorrhage and then we studied the correlation between the prediction and the plain CT 24 hours after the contrast-enhanced CT scan. The results were as follows: 1) The prediction was correct in 13 cases out of 16 cases in which the development of contusional hemorrhage was observed. In 18 cases where no development of contusional hemorrhage was observed, the prediction was correct without exception. 2) Most of the cases in which enhancement was demonstrated were ones examined not before 3 hours after injury. 3) The extent of enhancement shown on contrastenhanced CT scan was well consistent with that of contusional hemorrhage on the plain CT scan 24 hours after the contrast-enhanced CT scan. From these results, the contrast-enhanced CT scan in acute stage of head injury was considered to by very useful in prediction of the development of contusional hemorrhage. (author)

  14. A contrast enhancement and scanning techniques for CT angiography of head and neck. One phase injection method for simultaneous imaging of vessels and tumor

    International Nuclear Information System (INIS)

    Morita, Yasuhiko; Indo, Hiroko; Noikura, Takenori

    1999-01-01

    We report on a method of CT-Angiography useful for examining lesion of the head and neck using three-dimensional images and measured CT value. This study focused on some of the important blood vessels in the head and neck. The aim of this method was to obtain high-contrast enhancement for both vessels and tumors at same time. A total amount of 100 ml nonionic contrast media (Omnipaque 240, 240 mg iodine per milliliter, Daiichi seiyaku, Tokyo, Japan) was injected intravenously with a flow of 1.5 ml/sec. Spiral scans, 24 rotations with 24 seconds, were started at a time when remaining amount of contrast media had become 30 to 20 ml. All CT scans were performed using double speed spiral scan technique with a slice thickness of 2 to 3 mm and table speeds from 3 to 5 mm/rotation. The patients populations consisted of 9 men and 6 women who ranged in age from 37 to 85 years. Sixteen CT-angiography were performed according to this method. Mean CT values of major blood vessels were measured in order to find out threshold at the level of submandibular gland in 13 examinations for 12 subjects. Important vessels like the common, internal, and the external artery, internal and external jugular vein were clearly visible in all subjects. Three dimensional images of these vessels could also be reconstructed for 15 of the subjects. Mean CT values were 211 Hounsfield units (HU) and 209 HU for the right and left internal carotid artery, respectively, and 204 HU and 206 HU for the right and left external carotid artery, respectively. Mean CT values for right and left internal jugular vein were 195 HU and 194 HU respectively. Measured CT values at each important blood vessels showed this method could yields acceptable enhancements. Good enhancement effect of tumor and blood vessels in the same scan seems to be mutually incompatible. One very important trade-off is the early enhancement effect at blood vessels versus the late enhancement effect at tumors. The other important trade

  15. Contrast-enhanced fat- suppression MR imaging of avascular necrosis of femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Tae Kyoung; Shim, Jae Chan; Lee, Ghi Jai; Jeon, Jeong Dong; Bang, Sun Woo; Kim, Ho Kyun [College of Medicine, Inje University, Seoul (Korea, Republic of)

    2000-02-01

    To evaluate the findings and role of contrast-enhanced fat suppression MR imaging in avascular necrosis (AVN) of the femoral head. In 15 patients with AVN of the femoral head, MR T1-weighted and T2-weighted images and contrast-enhanced fat-suppression T1-weighted images were obtained, and the findings were reviewed. Early and advanced groups were classified on the basis of clinical findings and imaging, and the enhancement pattern was classified as either type I, rim enhancement; type II, surrounding diffuse enhancement; type III, intralesional enhancement; or type IV, II + III. Twenty-four cases of AVN of the femoral head were detected; in nine patients, lesions were bilateral. Eight cases occurred in the early group and 16 in the advanced. All eight in the early group showed the 'double line sign' on T2-weighted images, with a type-I enhancement pattern. In the advanced group, type II (8/16) and type IV (8/16) enhancement patterns were seen. Among the cases showing the type-IV pattern, the intralesional enhancing area showed low signal intensity on T1-weighted images and isosignal intensity on T2-weighted in one case, and low signal intensity on T2-weighted in one case, and low signal intensity on T1-weighted images and high signal intensity on T2-weighted in the other cases. There was no difference in the extent of the disease before and after enhancement. Contrast-enhanced fat-suppression MR images may be helpful in evaluating the extent of AVN of the femoral head and predicting the histopathologic findings of the disease. (author)

  16. Contrast-enhanced fat- suppression MR imaging of avascular necrosis of femoral head

    International Nuclear Information System (INIS)

    Oh, Tae Kyoung; Shim, Jae Chan; Lee, Ghi Jai; Jeon, Jeong Dong; Bang, Sun Woo; Kim, Ho Kyun

    2000-01-01

    To evaluate the findings and role of contrast-enhanced fat suppression MR imaging in avascular necrosis (AVN) of the femoral head. In 15 patients with AVN of the femoral head, MR T1-weighted and T2-weighted images and contrast-enhanced fat-suppression T1-weighted images were obtained, and the findings were reviewed. Early and advanced groups were classified on the basis of clinical findings and imaging, and the enhancement pattern was classified as either type I, rim enhancement; type II, surrounding diffuse enhancement; type III, intralesional enhancement; or type IV, II + III. Twenty-four cases of AVN of the femoral head were detected; in nine patients, lesions were bilateral. Eight cases occurred in the early group and 16 in the advanced. All eight in the early group showed the 'double line sign' on T2-weighted images, with a type-I enhancement pattern. In the advanced group, type II (8/16) and type IV (8/16) enhancement patterns were seen. Among the cases showing the type-IV pattern, the intralesional enhancing area showed low signal intensity on T1-weighted images and isosignal intensity on T2-weighted in one case, and low signal intensity on T2-weighted in one case, and low signal intensity on T1-weighted images and high signal intensity on T2-weighted in the other cases. There was no difference in the extent of the disease before and after enhancement. Contrast-enhanced fat-suppression MR images may be helpful in evaluating the extent of AVN of the femoral head and predicting the histopathologic findings of the disease. (author)

  17. Software-triggered contrast-enhanced three-dimensional MR angiography of the intracranial arteries.

    Science.gov (United States)

    Isoda, H; Takehara, Y; Isogai, S; Takeda, H; Tanaka, T; Takahashi, M; Nozaki, A; Sun, Y

    2000-02-01

    We investigated the effectiveness of software-triggered contrast-enhanced three-dimensional (3D) MR angiography in evaluating intracranial arteries. We studied 38 patients with suspected brain lesions. Imaging was performed using a 1.5-T superconducting MR system with a commercially available head coil. To monitor signal intensity changes we used software to place a tracker volume at the basilar artery or the internal carotid artery. A 20-ml bolus of gadodiamide hydrate was administered through the antecubital vein at a rate of 2-4 ml/sec, followed by a saline flush. Three-dimensional MR angiography using a spoiled gradient-echo sequence with centric K-space ordering was triggered by the arrival of the contrast bolus in the tracker volume. Imaging times ranged from 12 to 20 sec. We used MR images to assess the effectiveness of contrast-enhanced 3D MR angiography in revealing intracranial arteries with minimal venous overlap. The software triggered imaging on the arrival of the contrast bolus in 81.6% of examinations. In 77.6% of examinations, the resulting MR angiograms revealed intracranial arteries with minimal venous overlap. Software-triggered contrast-enhanced 3D MR angiography with centric K-space ordering is a promising technique for viewing intracranial arteries.

  18. Which one Enhances Muscular Performance in ACL Reconstructed Subjects

    Science.gov (United States)

    Harput, Gulcan; Ulusoy, Burak; Atay, Ahmet Ozgur; Baltacı, Gul

    2014-01-01

    Objectives: The aim of this study was to investigate the effects of functional knee brace and kinesiotaping on muscular performance in anterior cruciate ligament reconstructed subjects who reached return to sport phase of the rehabilitation. Methods: Twenty (17 males, 3 females, Age: 24.7±7.1 years, Body weight: 74.4±12.0 kg, Height: 177.9±6.5 cm, BMI: 23.9±3.6 kg/m2) subjects who underwent anterior cruciate ligament reconstruction by using hamstring tendon auto graft were included in this study. When the subjects reached the return to sports phase of rehabilitation which was 6th months after surgery, knee muscle strength, jump performance and balance tests were performed 3 times: bare, with knee brace and with kinesio taping. The order of the tests were randomized to eliminate the effects of fatigue and motor learning. Quadriceps and hamstring muscle strength was measured on an isokinetic dynamometer at 180 °/s and 60°/s angular velocities. Vertical Jump (VJ) and One Leg Hop Tests (OLHT) were used to assess jump performance. Star Excursion Balance Test (SEBT) with anterior, posteromedial and posterolateral reach distance was used to assess the dynamic balance. When all tests were performed, the subjects were asked under which test condition they felt more confident. Repeated measures of ANOVA was used to analyze the difference among three test conditions (bare, kinesiotaping, knee brace). Bonferroni post hoc test was used for pairwise comparison. Results: SEBT posteromedial (PM)and posterolateral (PL) reach distances were found significantly different among three test conditions(PM: F(2,38)=3.42,p=0.04), PL: F(2,38)=4.37,p=0.02). Kinesiotaping increased posteromedial reach distance (p=0.03). On the other hand, brace decreased posterolateral reach distance (p=0.04). VJ and OLHT performance were also found significantly different between three test conditions (VJ: F (2,38)=3.44,p=0.04, OLHT: (F(2,38)=4.04,p=0.02). Kinesio taping increased one leg hop distance

  19. Differential evolution optimization combined with chaotic sequences for image contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Santos Coelho, Leandro dos [Industrial and Systems Engineering Graduate Program, LAS/PPGEPS, Pontifical Catholic University of Parana, PUCPR Imaculada Conceicao, 1155, 80215-901 Curitiba, Parana (Brazil)], E-mail: leandro.coelho@pucpr.br; Sauer, Joao Guilherme [Industrial and Systems Engineering Graduate Program, LAS/PPGEPS, Pontifical Catholic University of Parana, PUCPR Imaculada Conceicao, 1155, 80215-901 Curitiba, Parana (Brazil)], E-mail: joao.sauer@gmail.com; Rudek, Marcelo [Industrial and Systems Engineering Graduate Program, LAS/PPGEPS, Pontifical Catholic University of Parana, PUCPR Imaculada Conceicao, 1155, 80215-901 Curitiba, Parana (Brazil)], E-mail: marcelo.rudek@pucpr.br

    2009-10-15

    Evolutionary Algorithms (EAs) are stochastic and robust meta-heuristics of evolutionary computation field useful to solve optimization problems in image processing applications. Recently, as special mechanism to avoid being trapped in local minimum, the ergodicity property of chaotic sequences has been used in various designs of EAs. Three differential evolution approaches based on chaotic sequences using logistic equation for image enhancement process are proposed in this paper. Differential evolution is a simple yet powerful evolutionary optimization algorithm that has been successfully used in solving continuous problems. The proposed chaotic differential evolution schemes have fast convergence rate but also maintain the diversity of the population so as to escape from local optima. In this paper, the image contrast enhancement is approached as a constrained nonlinear optimization problem. The objective of the proposed chaotic differential evolution schemes is to maximize the fitness criterion in order to enhance the contrast and detail in the image by adapting the parameters using a contrast enhancement technique. The proposed chaotic differential evolution schemes are compared with classical differential evolution to two testing images. Simulation results on three images show that the application of chaotic sequences instead of random sequences is a possible strategy to improve the performance of classical differential evolution optimization algorithm.

  20. Prognostic significance of contrast-enhanced CT attenuation value in extrahepatic cholangiocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Asayama, Yoshiki [Kyushu University, Department of Advanced Imaging and Interventional Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Nishie, Akihiro; Ishigami, Kousei; Ushijima, Yasuhiro; Takayama, Yukihisa; Okamoto, Daisuke; Fujita, Nobuhiro; Honda, Hiroshi [Kyushu University, Departments of Clinical Radiology, Fukuoka (Japan); Ohtsuka, Takao [Kyushu University, Departments of Surgery and Oncology, Fukuoka (Japan); Yoshizumi, Tomoharu [Kyushu University, Departments of Surgery and Sciences, Fukuoka (Japan); Aishima, Shinichi [Saga University, Pathology and Microbiology, Faculty of Medicine, Saga (Japan); Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan); Oda, Yoshinao [Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2017-06-15

    To determine whether washout characteristics of dynamic contrast-enhanced computed tomography (CT) could predict survival in patients with extrahepatic cholangiocarcinoma (EHC). This study collected 46 resected cases. All cases were examined by dynamic contrast study on multidetector-row CT. Region-of-interest measurements were obtained at the non-enhanced, portal venous phase and delayed phase in the tumour and were used to calculate the washout ratio as follows: [(attenuation value at portal venous phase CT - attenuation value at delayed enhanced CT)/(attenuation value at portal venous phase CT - attenuation value at unenhanced CT)] x 100. On the basis of the median washout ratio, we classified the cases into two groups, a high-washout group and low-washout group. Associations between overall survival and various factors including washout rates were analysed. The median washout ratio was 29.4 %. Univariate analysis revealed that a lower washout ratio, venous invasion, lymphatic permeation and lymph node metastasis were associated with shorter survival. Multivariate analysis identified the lower washout ratio as an independent prognostic factor (hazard ratio, 3.768; p value, 0.027). The washout ratio obtained from the contrast-enhanced CT may be a useful imaging biomarker for the prediction of survival of patients with EHC. (orig.)

  1. Dual contrast enhanced magnetic resonance imaging of the liver with superparamagnetic iron oxide followed by gadolinium for lesion detection and characterization

    International Nuclear Information System (INIS)

    Kubaska, Samantha; Sahani, Dushyant V.; Saini, Sanjay; Hahn, Peter F.; Halpern, Elkan

    2001-01-01

    AIM: Iron oxide contrast agents are useful for lesion detection, and extracellular gadolinium chelates are advocated for lesion characterization. We undertook a study to determine if dual contrast enhanced liver imaging with sequential use of ferumoxides particles and gadolinium (Gd)-DTPA can be performed in the same imaging protocol. MATERIALS AND METHODS: Sixteen patients underwent dual contrast magnetic resonance imaging (MRI) of the liver for evaluation of known/suspected focal lesions which included, metastases (n = 5), hepatocellular carcinoma (HCC;n = 3), cholangiocharcinoma(n = 1) and focal nodular hyperplasia (FNH;n = 3). Pre- and post-iron oxide T1-weighted gradient recalled echo (GRE) and T2-weighted fast spin echo (FSE) sequences were obtained, followed by post-Gd-DTPA (0.1 mmol/kg) multi-phase dynamic T1-weighted out-of-phase GRE imaging. Images were analysed in a blinded fashion by three experts using a three-point scoring system for lesion conspicuity on pre- and post-iron oxide T1 images as well as for reader's confidence in characterizing liver lesions on post Gd-DTPA T1 images. RESULTS: No statistically significant difference in lesion conspicuity was observed on pre- and post-iron oxide T1-GRE images in this small study cohort. The presence of iron oxide did not appreciably diminish image quality of post-gadolinium sequences and did not prevent characterization of liver lesions. CONCLUSION: Our results suggest that characterization of focal liver lesion with Gd-enhanced liver MRI is still possible following iron oxide enhanced imaging. Kubaska, S. et al. (2001)

  2. Analysis of achilles tendon vascularity with second-generation contrast-enhanced ultrasound.

    Science.gov (United States)

    Genovese, Eugenio; Ronga, Mario; Recaldini, Chiara; Fontana, Federico; Callegari, Leonardo; Maffulli, Nicola; Fugazzola, Carlo

    2011-01-01

    To compare morphological, power Doppler, and contrast-enhanced ultrasound (CEUS) features of the Achilles tendon between asymptomatic athletes and athletes who had undergone surgical repair of a previous rupture. Twenty-four athletes were divided in two groups (A and B). Group A included 14 patients with a median age of 32 years (range 27 to 47 years) who had undergone surgical repair for unilateral Achilles tendon rupture. Group B (control group) included 10 subjects with a median age of 34 years (range 27 to 40 years) with no previous or present history of tendinopathy. All patients were evaluated with ultrasound, power Doppler, and CEUS with second-generation contrast agent. We studied the uninjured Achilles tendon in athletes of group A and either the left or the right Achilles tendon of the athletes in group B. CEUS showed a significantly greater ability to detect a greater number of vascular spots within the uninjured tendon of group A compared to group B (power Doppler ultrasound in the uninjured contralateral Achilles tendon. CEUS is useful to evaluate vascularity not detected by other imaging techniques. Vascularity in the uninjured tendon seems to be increased in patients who had a previous rupture. Copyright © 2011 Wiley Periodicals, Inc.

  3. A new combined technique for automatic contrast enhancement of digital images

    Directory of Open Access Journals (Sweden)

    Ismail A. Humied

    2012-03-01

    Full Text Available Some low contrast images have certain characteristics makes it difficult to use traditional methods to improve it. An example of these characteristics, that the amplitudes of images histogram components are very high at one location on the gray scale and very small in the rest of the gray scale. In the present paper, a new method is described. It can deal with such cases. The proposed method is a combination of Histogram Equalization (HE and Fast Gray-Level Grouping (FGLG. The basic procedure of this method is segments the original histogram of a low contrast image into two sub-histograms according to the location of the highest amplitude of the histogram components, and achieving contrast enhancement by equalizing the left segment of the histogram components using (HE technique and using (FGLG technique to equalize the right segment of this histogram components. The results have shown that the proposed method does not only produce better results than each individual contrast enhancement technique, but it is also fully automated. Moreover, it is applicable to a broad variety of images that satisfy the properties mentioned above and suffer from low contrast.

  4. Clinical utility of three-dimensional contrast-enhanced ultrasound in the differentiation between noninvasive and invasive neoplasms of urinary bladder.

    Science.gov (United States)

    Li, Qiu-yang; Tang, Jie; He, En-hui; Li, Yan-mi; Zhou, Yun; Zhang, Xu; Chen, Guangfu

    2012-11-01

    The purpose of this study was to evaluate the effectiveness of three-dimensional contrast-enhanced ultrasound in differentiating invasive and noninvasive neoplasms of urinary bladder. A total of 60 lesions in 60 consecutive patients with bladder tumors received three dimensional ultrasonography, low acoustic power contrast enhanced ultrasonography and low acoustic power three-dimensional contrast-enhanced ultrasound examination. The IU22 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The contrast-specific sonographic imaging modes were PI (pulse inversion) and PM (power modulation). The three dimensional ultrasonography, contrast enhanced ultrasonography, and three-dimensional contrast-enhanced ultrasound images were independently reviewed by two readers who were not in the images acquisition. Images were analyzed off-site. A level of confidence in the diagnosis of tumor invasion of the muscle layer was assigned on a 5° scale. Receiver operating characteristic analysis was used to assess overall confidence in the diagnosis of muscle invasion by tumor. Kappa values were used to assess inter-readers agreement. Histologic diagnosis was obtained for all patients. Final pathologic staging revealed 44 noninvasive tumors and 16 invasive tumors. Three-dimensional contrast-enhanced ultrasound depicted all 16 muscle-invasive tumors. The diagnostic performance of three-dimensional contrast-enhanced ultrasound was better than those of three dimensional ultrasonography and contrast enhanced ultrasonography. The receiver operating characteristic curves were 0.976 and 0.967 for three-dimensional contrast-enhanced ultrasound, those for three dimensional ultrasonography were 0.881 and 0.869, those for contrast enhanced ultrasonography were 0.927 and 0.929. The kappa values in the three dimensional ultrasonography, contrast enhanced ultrasonography and three-dimensional contrast-enhanced ultrasound for inter-reader agreements

  5. Clinical utility of three-dimensional contrast-enhanced ultrasound in the differentiation between noninvasive and invasive neoplasms of urinary bladder

    International Nuclear Information System (INIS)

    Li, Qiu-yang; Tang, Jie; He, En-hui; Li, Yan-mi; Zhou, Yun; Zhang, Xu; Chen, Guangfu

    2012-01-01

    Objectives: The purpose of this study was to evaluate the effectiveness of three-dimensional contrast-enhanced ultrasound in differentiating invasive and noninvasive neoplasms of urinary bladder. Methods: A total of 60 lesions in 60 consecutive patients with bladder tumors received three dimensional ultrasonography, low acoustic power contrast enhanced ultrasonography and low acoustic power three-dimensional contrast-enhanced ultrasound examination. The IU22 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The contrast-specific sonographic imaging modes were PI (pulse inversion) and PM (power modulation). The three dimensional ultrasonography, contrast enhanced ultrasonography, and three-dimensional contrast-enhanced ultrasound images were independently reviewed by two readers who were not in the images acquisition. Images were analyzed off-site. A level of confidence in the diagnosis of tumor invasion of the muscle layer was assigned on a 5° scale. Receiver operating characteristic analysis was used to assess overall confidence in the diagnosis of muscle invasion by tumor. Kappa values were used to assess inter-readers agreement. Histologic diagnosis was obtained for all patients. Results: Final pathologic staging revealed 44 noninvasive tumors and 16 invasive tumors. Three-dimensional contrast-enhanced ultrasound depicted all 16 muscle-invasive tumors. The diagnostic performance of three-dimensional contrast-enhanced ultrasound was better than those of three dimensional ultrasonography and contrast enhanced ultrasonography. The receiver operating characteristic curves were 0.976 and 0.967 for three-dimensional contrast-enhanced ultrasound, those for three dimensional ultrasonography were 0.881 and 0.869, those for contrast enhanced ultrasonography were 0.927 and 0.929. The kappa values in the three dimensional ultrasonography, contrast enhanced ultrasonography and three-dimensional contrast-enhanced ultrasound

  6. The role of contrast-enhanced digital subtraction MRI in the diagnosis of vertebral metastasic tumors

    International Nuclear Information System (INIS)

    Xiao Yeyu; Yang Jun; Qi Weili; Liu Qize; Hong Bikai; Wu Renhua

    2008-01-01

    Objective: To evaluate the contrast-enhanced digital subtraction MRI in the diagnosis of vertebral metastasic tumors. Methods 66 vertebral metastasic tumors in 43 patients were examined with conventional MRI (T 1 WI, STIR and Contrast-enhanced T 1 WI) and contrast-enhanced digital subtraction MR imaging. All lesions were histologically proved. The quantity and characteristic imaging signs (including spiculation, bull eye sign and irregular edge) of lesions were detected separately by different sequences. K independent samples test was used. Results: The detection rates of 35 vertebral metastasic tumors with vertebral morphological changes were same in all MR sequences. But in the other 31 lesions without vertebral morphological changes, the detection rates were different and STIR was the highest in all sequences. Contrast-enhanced digital subtraction MRI was more sensitive than all the conventional MR sequences in finding characteristic imaging signs with statistically significant differences. Conclusion: Contrast enhanced subtraction MRI is an useful and convenient technique which has great value in finding vertebral metastasic tumors and depicting the characteristic imaging signs. (authors)

  7. Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jinhee; Kim, Bom-yi; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin; Kim, Bum-soo [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, Seoul (Korea, Republic of); Schmitt, Peter [Siemens AG, Healthcare Sector, Erlangen (Germany); Kim, Inseong; Paek, Munyoung [Siemens AG, Healthcare, Seoul (Korea, Republic of)

    2014-04-15

    This study aimed to evaluate the feasibility of non-contrast-enhanced 4D magnetic resonance angiography (NCE 4D MRA) with signal targeting with alternative radiofrequency (STAR) spin labeling and variable flip angle (VFA) sampling in the assessment of dural arteriovenous fistula (DAVF) in the transverse sinus. Nine patients underwent NCE 4D MRA for the evaluation of DAVF in the transverse sinus at 3 T. One patient was examined twice, once before and once after the interventional treatment. All patients also underwent digital subtraction angiography (DSA) and/or contrast-enhanced magnetic resonance angiography (CEMRA). For the acquisition of NCE 4D MRA, a STAR spin tagging method was used, and a VFA sampling was applied in the data readout module instead of a constant flip angle. Two readers evaluated the NCE 4D MRA data for the diagnosis of DAVF and its type with consensus. The results were compared with those from DSA and/or CEMRA. All patients underwent NCE 4D MRA without any difficulty. Among seven patients with patent DAVFs, all cases showed an early visualization of the transverse sinus on NCE 4D MRA. Except for one case, the type of DAVF of NCE 4D MRA was agreed with that of reference standard study. Cortical venous reflux (CVR) was demonstrated in two cases out of three patients with CVR. NCE 4D MRA with STAR tagging and VFA sampling is technically and clinically feasible and represents a promising technique for assessment of DAVF in the transverse sinus. Further technical developments should aim at improvements of spatial and temporal coverage. (orig.)

  8. Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula

    International Nuclear Information System (INIS)

    Jang, Jinhee; Kim, Bom-yi; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin; Kim, Bum-soo; Schmitt, Peter; Kim, Inseong; Paek, Munyoung

    2014-01-01

    This study aimed to evaluate the feasibility of non-contrast-enhanced 4D magnetic resonance angiography (NCE 4D MRA) with signal targeting with alternative radiofrequency (STAR) spin labeling and variable flip angle (VFA) sampling in the assessment of dural arteriovenous fistula (DAVF) in the transverse sinus. Nine patients underwent NCE 4D MRA for the evaluation of DAVF in the transverse sinus at 3 T. One patient was examined twice, once before and once after the interventional treatment. All patients also underwent digital subtraction angiography (DSA) and/or contrast-enhanced magnetic resonance angiography (CEMRA). For the acquisition of NCE 4D MRA, a STAR spin tagging method was used, and a VFA sampling was applied in the data readout module instead of a constant flip angle. Two readers evaluated the NCE 4D MRA data for the diagnosis of DAVF and its type with consensus. The results were compared with those from DSA and/or CEMRA. All patients underwent NCE 4D MRA without any difficulty. Among seven patients with patent DAVFs, all cases showed an early visualization of the transverse sinus on NCE 4D MRA. Except for one case, the type of DAVF of NCE 4D MRA was agreed with that of reference standard study. Cortical venous reflux (CVR) was demonstrated in two cases out of three patients with CVR. NCE 4D MRA with STAR tagging and VFA sampling is technically and clinically feasible and represents a promising technique for assessment of DAVF in the transverse sinus. Further technical developments should aim at improvements of spatial and temporal coverage. (orig.)

  9. Quantifying heterogeneity of lesion uptake in dynamic contrast enhanced MRI for breast cancer diagnosis

    International Nuclear Information System (INIS)

    Karahaliou, A; Skiadopoulos, S; Yiakoumelos, A; Costaridou, L; Vassiou, K; Kanavou, T

    2009-01-01

    The current study investigates whether texture features extracted from lesion kinetics feature maps can be used for breast cancer diagnosis. Fifty five women with 57 breast lesions (27 benign, 30 malignant) were subjected to dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) on 1.5T system. A linear-slope model was fitted pixel-wise to a representative lesion slice time series and fitted parameters were used to create three kinetic maps (wash out, time to peak enhancement and peak enhancement). 28 grey level co-occurrence matrices features were extracted from each lesion kinetic map. The ability of texture features per map in discriminating malignant from benign lesions was investigated using a Probabilistic Neural Network classifier. Additional classification was performed by combining classification outputs of most discriminating feature subsets from the three maps, via majority voting. The combined scheme outperformed classification based on individual maps achieving area under Receiver Operating Characteristics curve 0.960±0.029. Results suggest that heterogeneity of breast lesion kinetics, as quantified by texture analysis, may contribute to computer assisted tissue characterization in DCE-MRI.

  10. Importance of contrast-enhanced fluid-attenuated inversion reconvery magnetic resonance imaging in various intracranial pathologic conditions

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Kyoung; Lee, Eun Ja; Kim, Sung Won; Lee, Yong Seok [Dept. of Radiology, Dongguk University Ilsan Hospital, Goyang(Korea, Republic of)

    2016-02-15

    Intracranial lesions may show contrast enhancement through various mechanisms that are closely associated with the disease process. The preferred magnetic resonance sequence in contrast imaging is T1-weighted imaging (T1WI) at most institutions. However, lesion enhancement is occasionally inconspicuous on T1WI. Although fluid-attenuated inversion recovery (FLAIR) sequences are commonly considered as T2-weighted imaging with dark cerebrospinal fluid, they also show mild T1-weighted contrast, which is responsible for the contrast enhancement. For several years, FLAIR imaging has been successfully incorporated as a routine sequence at our institution for contrast-enhanced (CE) brain imaging in detecting various intracranial diseases. In this pictorial essay, we describe and illustrate the diagnostic importance of CE-FLAIR imaging in various intracranial pathologic conditions.

  11. Detection of cavernous transformation of the portal vein by contrast-enhanced ultrasound.

    Science.gov (United States)

    Hwang, Misun; Thimm, Matthew A; Guerrerio, Anthony L

    2018-06-01

    Cavernous transformation of the portal vein can be missed on color Doppler exam or arterial phase cross-sectional imaging due to their slow flow and delayed enhancement. Contrast-enhanced ultrasound (CEUS) offers many advantages over other imaging techniques and can be used to successfully detect cavernous transformations of the portal vein. A 10-month-old female was followed for repeat episodes of hematemesis. Computed tomography angiography (CTA) and magnetic resonance arteriogram (MRA) and portal venography were performed. Color Doppler exam of the portal vein was performed followed by administration of Lumason, a microbubble US contrast agent. Magnetic resonance arteriogram, CTA, and color Doppler exam at the time of initial presentation was unremarkable without obvious vascular malformation within the limits of motion degraded exam. At 8-month follow-up, esophagogastroduodenoscopy revealed a vascular malformation in the distal esophagus which was sclerosed. At 6 month after sclerosis of the lesion, portal venography revealed occlusion of the portal vein with extensive collateralization. Color Doppler revealed subtle hyperarterialization and periportal collaterals. CEUS following color Doppler exam demonstrated extensive enhancement of periportal collaterals. Repeat color Doppler after contrast administration demonstrated extensive Doppler signal in the collateral vessels, suggestive of cavernous transformation. We describe a case of cavernous transformation of the portal vein missed on initial color Doppler, CTA and MRA, but detected with contrast-enhanced ultrasound technique.

  12. Image contrast enhancement based on a local standard deviation model

    International Nuclear Information System (INIS)

    Chang, Dah-Chung; Wu, Wen-Rong

    1996-01-01

    The adaptive contrast enhancement (ACE) algorithm is a widely used image enhancement method, which needs a contrast gain to adjust high frequency components of an image. In the literature, the gain is usually inversely proportional to the local standard deviation (LSD) or is a constant. But these cause two problems in practical applications, i.e., noise overenhancement and ringing artifact. In this paper a new gain is developed based on Hunt's Gaussian image model to prevent the two defects. The new gain is a nonlinear function of LSD and has the desired characteristic emphasizing the LSD regions in which details are concentrated. We have applied the new ACE algorithm to chest x-ray images and the simulations show the effectiveness of the proposed algorithm

  13. Diffusion-weighted imaging in relation to morphology on dynamic contrast enhancement MRI. The diagnostic value of characterizing non-puerperal mastitis

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Lina; Chu, Jianguo; Zhang, Weisheng; Liu, Ailian; Song, Qingwei [First Affiliated Hospital of Dalian Medical University, Department of Radiology, Dalian, Liaoning (China); Hu, Jiani; Guys, Nicholas [Wayne State University, Department of Radiology, Detroit, MI (United States); Meng, Jinli [Chengban Branch of West China Hospital, Department of Radiology, Chengdu, Sichuan (China); Wang, Shaowu [Second Affiliated Hospital of Dalian Medical University, Department of Radiology, Dalian, Liaoning (China)

    2018-03-15

    To demonstrate the value of diffusion-weighted imaging (DWI) in the characterisation of mastitis lesions. Sixty-one non-puerperal patients with pathologically confirmed single benign mastitis lesions underwent preoperative examinations with conventional MRI and axial DWI. Patients were categorised into three groups: (1) periductal mastitis (PDM), (2) granulomatous lobular mastitis (GLM), and (3) infectious abscess (IAB). Apparent diffusion coefficient (ADC) values of each lesion were recorded. A one-way ANOVA with logistic analysis was performed to compare ADC values and other parameters. Discriminative abilities of DWI modalities were compared using the area under the receiver operating characteristic curve (AUC). P < 0.05 was considered statistically significant. ADC values differed significantly among the three groups (P = 0.003) as well as between PDM and IAB and between PDM and GLM. The distribution of non-mass enhancement on dynamic contrast-enhanced (DCE) MRI differed significantly among the three groups (P = 0.03) but not between any two groups specifically. There were no differences in lesion location, patient age, T{sub 2}WI or DWI signal intensity, enhancement type, non-mass internal enhancement, or mass enhancement characteristics among the three groups. ADC values and the distribution of non-mass enhancement are valuable in classifying mastitis subtypes. (orig.)

  14. FDG-avid portal vein tumor thrombosis from hepatocellular carcinoma in contrast-enhanced FDG PET/CT

    Directory of Open Access Journals (Sweden)

    Canh Nguyen

    2015-01-01

    Full Text Available Objective(s: In this study, we aimed to describe the characteristics of portal vein tumor thrombosis (PVTT, complicating hepatocellular carcinoma (HCC in contrast-enhanced FDG PET/CT scan. Methods: In this retrospective study, 9 HCC patients with FDG-avid PVTT were diagnosed by contrast-enhanced fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT, which is a combination of dynamic liver CT scan, multiphase imaging, and whole-body PET scan. PET and CT DICOM images of patients were imported into the PET/CT imaging system for the re-analysis of contrast enhancement and FDG uptake in thrombus, the diameter of the involved portal vein, and characteristics of liver tumors and metastasis. Results: Two patients with previously untreated HCC and 7 cases with previously treated HCC had FDG-avid PVTT in contrast-enhanced FDG PET/CT scan. During the arterial phase of CT scan, portal vein thrombus showed contrast enhancement in 8 out of 9 patients (88.9%. PET scan showed an increased linear FDG uptake along the thrombosed portal vein in all patients. The mean greatest diameter of thrombosed portal veins was 1.8 ± 0.2 cm, which was significantly greater than that observed in normal portal veins (P<0.001. FDG uptake level in portal vein thrombus was significantly higher than that of blood pool in the reference normal portal vein (P=0.001. PVTT was caused by the direct extension of liver tumors. All patients had visible FDG-avid liver tumors in contrast-enhanced images. Five out of 9 patients (55.6% had no extrahepatic metastasis, 3 cases (33.3% had metastasis of regional lymph nodes, and 1 case (11.1% presented with distant metastasis. The median estimated survival time of patients was 5 months. Conclusion: The intraluminal filling defect consistent with thrombous within the portal vein, expansion of the involved portal vein, contrast enhancement, and linear increased FDG uptake of the thrombus extended from liver tumor are

  15. Pathologic contrast enhancement of cerebral lesions: A comparative study using stereotactic CT, stereotactic MR imaging, and stereotactic biopsy

    International Nuclear Information System (INIS)

    Earnest, F. IV; Kelly, P.J.; Scheithauer, B.; Kall, B.; Cascino, T.L.; Ehman, R.L.; Forbes, G.

    1986-01-01

    The author compared the pattern and degree of Gd-DTPA dimeglumine contrast enhancement demonstrated on stereotactic MR images with that seen on stereotactic CT images obtained after conventional iodinated contrast agent enhancement and with histopathologic findings on sequential stereotactic brain biopsies. Stereotactic biopsies of the areas that enhanced on CT or MR imaging revealed tumor tissue with neovascularity. Tumor tissue with no or mild neovascularity did not enhance with contrast agent administration. Isolated tumor cells were frequently found beyond the margins of some primary brain neoplasms defined by contrast agent-enhanced MR imaging and CT. The histopathologic findings associated with pathologic contrast agent enhancement are presented

  16. Infrared Contrast Enhancement Through Log-Power Histogram Modification

    NARCIS (Netherlands)

    Toet, A.; Wu, T.

    2015-01-01

    A simple power-logarithm histogram modification operator is proposed to enhance infrared (IR) image contrast. The algorithm combines a logarithm operator that smoothes the input image histogram while retaining the relative ordering of the original bins, with a power operator that restores the

  17. Contrast induced nephropathy in patients undergoing intravenous (IV) contrast enhanced computed tomography (CECT) and the relationship with risk factors: a meta-analysis

    NARCIS (Netherlands)

    Moos, Shira I.; van Vemde, David N. H.; Stoker, Jaap; Bipat, Shandra

    2013-01-01

    To summarize the incidence of contrast-induced nephropathy (CIN) and associations between CIN incidence and risk factors in patients undergoing intravenous contrast-enhanced computed tomography (CECT) with low- or iso-osmolar iodinated contrast medium. This review is performed in accordance with the

  18. Contrast-enhanced color Doppler ultrasound characteristics in hypervascular breast tumors: comparison with MRI

    International Nuclear Information System (INIS)

    Alamo, L.; Fischer, U.

    2001-01-01

    The aim of this study was to evaluate the accuracy of contrast-enhanced color Doppler ultrasound (CE-US) in comparison with contrast-enhanced MR imaging (CE-MRI) in the discrimination of hypervascularized breast tumors. An additional CE-US of the breast was preoperatively performed in 40 patients with a hypervascular breast lesion detected on CE-MRI. The presence of blood flow signals and the morphological characteristics of the vessels in the breast lesions were evaluated pre- and post-contrast administration, as well as the dynamic aspects of the Doppler signal, including time interval to maximum signal enhancement and persistence of the signal enhancement. Twenty-three carcinomas and 17 fibroadenomas were explored. Considering initial signal enhancement > 100 % after the administration of contrast material as a criterion suggesting malignancy, CE-MRI showed a sensitivity of 100 % and a specificity of 76.5 % in the detection of malignant breast tumors. Color Doppler signals were consistently demonstrated in all carcinomas and in 68.7 % of fibroadenomas after the administration of Levovist, with CE-US showing a sensitivity of 95.6 % and a specificity of 5.9 %. Neither the mean number of vessels per tumor, nor the location of vessels, the time to maximum increase of the Doppler signal or the persistence of signal enhancement showed significant differences between benign and malignant lesions. Additional CE-US does not increase the low specificity of MRI in patients with hypervascularized breast tumors. (orig.)

  19. A simulation study of enhancement duration in three-dimensional contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Ohkubo, Masaki; Ohgoshi, Yukio; Inoue, Tomoko; Naito, Kenichi; Suzuki, Kiyotaka

    2001-01-01

    In our study on three-dimensional (3D) contrast-enhanced MR angiography we performed a computer simulation to investigate quantitative vessel visibility. In the simulation, we evaluated the relative loss of signal intensity in a vessel due to shortened duration of contrast-enhancement. The mid-point of enhancement-duration was assumed to be at the point in which the data in the center of k-space (k y axis) was acquired. Signal intensity of a vessel decreased as the enhancement-duration was shortened and the diameter of the vessel was decreased. When the duration was shortened 40%, the signal intensity of a vessel in which the diameter was more than 2 pixels was preserved by approximately 70% or more. This suggests that the vessel visibility is high. When the duration was shortened 20%, the signal intensity of a vessel in which the diameter was less than 2 pixels decreased to less than approximately 40% or less. The simulation was confirmed by using 3D MR angiography with a tube phantom filled with Gd-DTPA to simulate a vessel model. At anytime during data acquisition, we could set the phantom on the region being scanned or take it out by using the ''pause'' function of the MR scanner. This made it possible to change the enhancement-duration to match the simulation. Results of the phantom study were comparable to those of the simulation, suggesting that the simulation was valid. Our results and simple techniques for both the simulation and the phantom study using the ''pause'' function, were considered useful in the study of 3D MR angiography. (author)

  20. Digital contrast enhancement of 18Fluorine-fluorodeoxyglucose positron emission tomography images in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Pandey, Anil Kumar; Sharma, Sanjay Kumar; Agarwal, Krishan Kant; Sharma, Punit; Bal, Chandrasekhar; Kumar, Rakesh

    2016-01-01

    The role of 18 fluorodeoxyglucose positron emission tomography (PET) is limited for detection of primary hepatocellular carcinoma (HCC) due to low contrast to the tumor, and normal hepatocytes (background). The aim of the present study was to improve the contrast between the tumor and background by standardizing the input parameters of a digital contrast enhancement technique. A transverse slice of PET image was adjusted for the best possible contrast, and saved in JPEG 2000 format. We processed this image with a contrast enhancement technique using 847 possible combinations of input parameters (threshold “m” and slope “e”). The input parameters which resulted in an image having a high value of 2 nd order entropy, and edge content, and low value of absolute mean brightness error, and saturation evaluation metrics, were considered as standardized input parameters. The same process was repeated for total nine PET-computed tomography studies, thus analyzing 7623 images. The selected digital contrast enhancement technique increased the contrast between the HCC tumor and background. In seven out of nine images, the standardized input parameters “m” had values between 150 and 160, and for other two images values were 138 and 175, respectively. The value of slope “e” was 4 in 4 images, 3 in 3 images and 1 in 2 images. It was found that it is important to optimize the input parameters for the best possible contrast for each image; a particular value was not sufficient for all the HCC images. The use of above digital contrast enhancement technique improves the tumor to background ratio in PET images of HCC and appears to be useful. Further clinical validation of this finding is warranted

  1. Contrast-enhanced voiding urosonography phantom study: intravenous iodinated and gadolinium-based contrast agents may cause false-negative results in assessment of vesicoureteral reflux in children

    International Nuclear Information System (INIS)

    Veldhoen, Simon; Sauer, Alexander; Gassenmaier, Tobias; Petritsch, Bernhard; Herz, Stefan; Blanke, Philipp; Bley, Thorsten A.; Wirth, Clemens; Derlin, Thorsten

    2015-01-01

    Contrast-enhanced voiding urosonography (ce-VUS) is commonly requested simultaneously to other diagnostic imaging necessitating intravenous contrast agents. To date there is limited knowldedge about intravesical interactions between different types of contrast agents. To assess the effect of excreted intravenous iodinated and gadolinium-based contrast agents on the intravesical distribution of ultrasound contrast within contrast-enhanced voiding urosonography. Iodinated (iomeprol, iopamidol) and gadolinium-based (gadoterate meglumine) contrast agents were diluted to bladder concentration and injected into balloons filled with saline solution. CT scans were performed to assess the contrast distribution in these phantoms. Regions of interest were placed at the top and bottom side of each balloon and Hounsfield units (HU) were measured. Three other balloons were filled with saline solution and contrast media likewise. The ultrasound contrast agent sulphur hexafluoride was added and its distribution was assessed using sonography. MDCT scans showed a separation of two liquid layers in all bladder phantoms with the contrast layers located at the bottom and the saline solution at the top. Significant differences of the HU measurements at the top and bottom side were observed (P < 0.001-0.007). Following injection of ultrasound contrast agent, US showed its distribution exclusively among the saline solution. False-negative results of contrast-enhanced voiding urosonography may occur if it is performed shortly after imaging procedures requiring intravenous contrast. (orig.)

  2. Fe Core–Carbon Shell Nanoparticles as Advanced MRI Contrast Enhancer

    Directory of Open Access Journals (Sweden)

    Rakesh P. Chaudhary

    2017-10-01

    Full Text Available The aim of this study is to fabricate a hybrid composite of iron (Fe core–carbon (C shell nanoparticles with enhanced magnetic properties for contrast enhancement in magnetic resonance imaging (MRI. These new classes of magnetic core–shell nanoparticles are synthesized using a one-step top–down approach through the electric plasma discharge generated in the cavitation field in organic solvents by an ultrasonic horn. Transmission electron microscopy (TEM observations revealed the core–shell nanoparticles with 10–85 nm in diameter with excellent dispersibility in water without any agglomeration. TEM showed the structural confirmation of Fe nanoparticles with body centered cubic (bcc crystal structure. Magnetic multi-functional hybrid composites of Fe core–C shell nanoparticles were then evaluated as negative MRI contrast agents, displaying remarkably high transverse relaxivity (r2 of 70 mM−1·S−1 at 7 T. This simple one-step synthesis procedure is highly versatile and produces desired nanoparticles with high efficacy as MRI contrast agents and potential utility in other biomedical applications.

  3. CT colonography: Diagnostic role of contrast enhancement of benign polyps and colorectal carcinoma

    International Nuclear Information System (INIS)

    Stoinova, V.; Nedevska, M.

    2006-01-01

    Full text: The aim of this study was to compare pre- and postcontrast CT attenuation values of benign colorectal polyps and carcinoma lesions detected by CT colonography, and to investigate whether contrast enhancement of these lesions can be potentially used for differentiation from residual fluid and feces. We retrospectively reviewed CT colonographic dataset of 120 patients. 35 benign polyps and 22 colorectal carcinomas were included in our study. All lesions were confirmed by colonoscopic biopsy or surgery. The difference in attenuation value between precontrast and postcontrast studies of polyps was statistically significant; the same was true for colorectal cancers. In the precontrast phase no statistically significant difference was observed between stool, polyps and cancers. The mean attenuation value of solid fecal residuals was 37 HU before and after contrast enhancement. Residual fluid do not take up contrast and the density does not change in the contrast-enhanced phase. The difference between postcontrast density of polyps and cancers with respect to density of stools and residual fluid was significant. The use of contrast medium could be helpful in CT colonography for discriminating polypoid benign lesions and colorectal cancer from fecal and fluid residuals

  4. Contrast-induced enphropathy in patients undergoing intravenous contrast-enhanced computed tomography in Korea; A multi-institutional study in 101487 patients

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joong Yub [Medical Research Collaborating Center, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Cho, Jeong Yeon [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jeong, Yong Yeon [Dept. of Radiology, Chonnam National University Hwasun Hospital, Chonnam National University Medical School, Hwasun (Korea, Republic of); and others

    2014-08-15

    To evaluate the prevalence of known risk factors for contrast-induced nephropathy (CIN) and their association with the actual occurrence of CIN in patients undergoing intravenous contrast-enhanced computed tomography (CECT) in Korea. Patients who underwent CECT in 2008 were identified in the electronic medical records of 16 tertiary hospitals of Korea. Data on demographics, comorbidities, prescriptions and laboratory test results of patients were collected following a standard data extraction protocol. The baseline renal function was assessed using the estimated glomerular filtration rate (eGFR). We identified the prevalence of risk factors along the eGFR strata and evaluated their influence on the incidence of CIN, defined as a 0.5 mg/dL or 25% increase in serum creatinine after CECT. Of 432425 CECT examinations in 272136 patients, 140838 examinations in 101487 patients met the eligibility criteria for analysis. The mean age of the participants was 57.9 ± 15.5 years; 25.1% of the patients were older than 70 years. The prevalence of diabetes mellitus was 11.9%, of hypertension 13.7%, of gout 0.55% and of heart failure was 1.7%. Preventive measures were used in 40238 CECT examinations (28.6%). The prevalence of risk factors and use of preventive measures increased as the renal function became worse. A CIN was occurred after 3103 (2.2%) CECT examinations, revealing a significant association with decreased eGFR, diabetes mellitus, and congestive heart failure after adjustment. Risk factors for CIN are prevalent among the patients undergoing CECT. Preventive measures were seemingly underutilized and a system is needed to improve preventive care.

  5. Hepatic blood perfusion estimated by dynamic contrast-enhanced computed tomography in pigs

    DEFF Research Database (Denmark)

    Winterdahl, Michael; Sørensen, Michael; Keiding, Inger Susanne

    2012-01-01

    The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates.......The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates....

  6. Virtual Non-Contrast CT Using Dual-Energy Spectral CT: Feasibility of Coronary Artery Calcium Scoring

    OpenAIRE

    Song, Inyoung; Yi, Jeong Geun; Park, Jeong Hee; Kim, Sung Mok; Lee, Kyung Soo; Chung, Myung Jin

    2016-01-01

    Objective To evaluate the feasibility of coronary artery calcium scoring based on three virtual noncontrast-enhanced (VNC) images derived from single-source spectral dual-energy CT (DECT) as compared with true noncontrast-enhanced (TNC) images. Materials and Methods This prospective study was conducted with the approval of our Institutional Review Board. Ninety-seven patients underwent noncontrast CT followed by contrast-enhanced chest CT using single-source spectral DECT. Iodine eliminated V...

  7. Non-contrast enhanced magnetic resonance angiography techniques in candidates for kidney transplantation: A comparative study

    International Nuclear Information System (INIS)

    Blankholm, Anne Dorte; Ginnerup-Pedersen, Bodil; Stausbøl-Grøn, Brian; Haislund, Margit; Laustsen, Sussie; Ringgaard, Steffen

    2013-01-01

    Aim: Detailed knowledge of vessel status in potential candidates for kidney transplantation is essential for the surgeon. Contrast enhanced magnetic resonance angiography has previously been used intensively for assessing this, but the discovery that use of gadolinium based contrast agents in magnetic resonance imaging can cause Nephrogenic Systemic Fibrosis in patients suffering from severe kidney disease has lead to renewed interest in non-contrast enhanced magnetic resonance angiography. The aim of this study was to find a non-contrast enhanced magnetic resonance angiography method for preoperative evaluation of the pelvic vessels prior to kidney transplantation, providing a sufficient image quality. Method: In a prospective study we consecutively included 54 patients undergoing examinations prior to kidney transplantation. The patients were examined with the following magnetic resonance angiography sequences: A 2D Time of flight (n = 54), 3D Time of flight (n = 52) patients, 3D Phase Contrast (n = 54), 3D Balanced Steady State Free Precession (n = 52) and a 2D TRiggered Angiography Non-Contrast Enhanced (TRANCE) (a Spin Echo sequence with subtraction) (n = 48). The sequences were evaluated with respect to contrast, diagnostic performance and artefact burden. Results: Evaluating contrast, 3D Phase Contrast was significantly better than 2D Time of flight (p 0.2). The 2D Time of flight was significantly better than the other sequences (p < 0.001) in all cases. The artefact score was lowest for the Phase Contrast images and significantly superior to the 2D Time of flight (p < 0.005). The 2D Time of flight was significantly better than the three other sequences (p < 0.001) in all cases. Conclusion: Non-contrast enhanced magnetic resonance angiography offers a safe preoperative examination for assessment of vessel status before kidney transplantation. A combination of 2D Time of flight and 3D Phase Contrast acquisitions is recommended and can be performed within a

  8. Local gray level S-curve transformation - A generalized contrast enhancement technique for medical images.

    Science.gov (United States)

    Gandhamal, Akash; Talbar, Sanjay; Gajre, Suhas; Hani, Ahmad Fadzil M; Kumar, Dileep

    2017-04-01

    Most medical images suffer from inadequate contrast and brightness, which leads to blurred or weak edges (low contrast) between adjacent tissues resulting in poor segmentation and errors in classification of tissues. Thus, contrast enhancement to improve visual information is extremely important in the development of computational approaches for obtaining quantitative measurements from medical images. In this research, a contrast enhancement algorithm that applies gray-level S-curve transformation technique locally in medical images obtained from various modalities is investigated. The S-curve transformation is an extended gray level transformation technique that results into a curve similar to a sigmoid function through a pixel to pixel transformation. This curve essentially increases the difference between minimum and maximum gray values and the image gradient, locally thereby, strengthening edges between adjacent tissues. The performance of the proposed technique is determined by measuring several parameters namely, edge content (improvement in image gradient), enhancement measure (degree of contrast enhancement), absolute mean brightness error (luminance distortion caused by the enhancement), and feature similarity index measure (preservation of the original image features). Based on medical image datasets comprising 1937 images from various modalities such as ultrasound, mammograms, fluorescent images, fundus, X-ray radiographs and MR images, it is found that the local gray-level S-curve transformation outperforms existing techniques in terms of improved contrast and brightness, resulting in clear and strong edges between adjacent tissues. The proposed technique can be used as a preprocessing tool for effective segmentation and classification of tissue structures in medical images. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Quantitative dynamic contrast-enhanced MR imaging analysis of complex adnexal masses: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Thomassin-Naggara, Isabelle [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Radiology, Paris (France); Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Service de Radiologie, Hopital Tenon, Paris (France); Balvay, Daniel [Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Aubert, Emilie; Bazot, Marc [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Radiology, Paris (France); Darai, Emile; Rouzier, Roman [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Gynaecology-Obstetrics, Paris (France); Cuenod, Charles A. [Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Hopital Europeen Georges Pompidou (HEGP), Department of Radiology, Paris (France)

    2012-04-15

    To evaluate the ability of quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to differentiate malignant from benign adnexal tumours. Fifty-six women with 38 malignant and 18 benign tumours underwent MR imaging before surgery for complex adnexal masses. Microvascular parameters were extracted from high temporal resolution DCE-MRI series, using a pharmacokinetic model in the solid tissue of adnexal tumours. These parameters were tissue blood flow (F{sub T}), blood volume fraction (Vb), permeability-surface area product (PS), interstitial volume fraction (Ve), lag time (Dt) and area under the enhancing curve (rAUC). Area under the receiver operating curve (AUROC) was calculated as a descriptive tool to assess the overall discrimination of parameters. Malignant tumours displayed higher F{sub T}, Vb, rAUC and lower Ve than benign tumours (P < 0.0001, P = 0.0006, P = 0.04 and P = 0.0002, respectively). F{sub T} was the most relevant factor for discriminating malignant from benign tumours (AUROC = 0.86). Primary ovarian invasive tumours displayed higher F{sub T} and shorter Dt than borderline tumours. Malignant adnexal tumours with associated peritoneal carcinomatosis at surgery displayed a shorter Dt than those without peritoneal carcinomatosis at surgery (P = 0.01). Quantitative DCE-MRI is a feasible and accurate technique to differentiate malignant from benign adnexal tumours and could potentially help oncologists with management decisions. (orig.)

  10. Effect of intensifying screens to subject contrast

    International Nuclear Information System (INIS)

    Lee, In Ja; Huh, Joon; Kang, Hong Seok; Yoon, Chul Ho

    1990-01-01

    It is an experimental report about object contrast according to the Kinds of screen and obtained results as follows ; 1. In the same object radiography, use acquired the difference of the object contrast between LT-II(CaWO 4 system) and G4(Gd system) screens. 2. object contrast more decreased in Gd system screen than CaWO 4 and object contrast controlled by X-ray tube voltage. 3. The difference of object contrast seen clearly in 80 kVp

  11. Medical Image Visual Appearance Improvement Using Bihistogram Bezier Curve Contrast Enhancement: Data from the Osteoarthritis Initiative

    Science.gov (United States)

    Gan, Hong-Seng; Swee, Tan Tian; Abdul Karim, Ahmad Helmy; Sayuti, Khairil Amir; Abdul Kadir, Mohammed Rafiq; Tham, Weng-Kit; Wong, Liang-Xuan; Chaudhary, Kashif T.; Yupapin, Preecha P.

    2014-01-01

    Well-defined image can assist user to identify region of interest during segmentation. However, complex medical image is usually characterized by poor tissue contrast and low background luminance. The contrast improvement can lift image visual quality, but the fundamental contrast enhancement methods often overlook the sudden jump problem. In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of “adequate contrast enhancement” to overcome sudden jump problem in knee magnetic resonance image. Since every image produces its own intensity distribution, the adequate contrast enhancement checks on the image's maximum intensity distortion and uses intensity discrepancy reduction to generate Bezier transform curve. The proposed method improves tissue contrast and preserves pertinent knee features without compromising natural image appearance. Besides, statistical results from Fisher's Least Significant Difference test and the Duncan test have consistently indicated that the proposed method outperforms fundamental contrast enhancement methods to exalt image visual quality. As the study is limited to relatively small image database, future works will include a larger dataset with osteoarthritic images to assess the clinical effectiveness of the proposed method to facilitate the image inspection. PMID:24977191

  12. Medical Image Visual Appearance Improvement Using Bihistogram Bezier Curve Contrast Enhancement: Data from the Osteoarthritis Initiative

    Directory of Open Access Journals (Sweden)

    Hong-Seng Gan

    2014-01-01

    Full Text Available Well-defined image can assist user to identify region of interest during segmentation. However, complex medical image is usually characterized by poor tissue contrast and low background luminance. The contrast improvement can lift image visual quality, but the fundamental contrast enhancement methods often overlook the sudden jump problem. In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of “adequate contrast enhancement” to overcome sudden jump problem in knee magnetic resonance image. Since every image produces its own intensity distribution, the adequate contrast enhancement checks on the image’s maximum intensity distortion and uses intensity discrepancy reduction to generate Bezier transform curve. The proposed method improves tissue contrast and preserves pertinent knee features without compromising natural image appearance. Besides, statistical results from Fisher’s Least Significant Difference test and the Duncan test have consistently indicated that the proposed method outperforms fundamental contrast enhancement methods to exalt image visual quality. As the study is limited to relatively small image database, future works will include a larger dataset with osteoarthritic images to assess the clinical effectiveness of the proposed method to facilitate the image inspection.

  13. Retinal nerve fiber layer measurements by scanning laser polarimetry with enhanced corneal compensation in healthy subjects.

    Science.gov (United States)

    Rao, Harsha L; Venkatesh, Chirravuri R; Vidyasagar, Kelli; Yadav, Ravi K; Addepalli, Uday K; Jude, Aarthi; Senthil, Sirisha; Garudadri, Chandra S

    2014-12-01

    To evaluate the (i) effects of biological (age and axial length) and instrument-related [typical scan score (TSS) and corneal birefringence] parameters on the retinal nerve fiber layer (RNFL) measurements and (ii) repeatability of RNFL measurements with the enhanced corneal compensation (ECC) protocol of scanning laser polarimetry (SLP) in healthy subjects. In a cross-sectional study, 140 eyes of 73 healthy subjects underwent RNFL imaging with the ECC protocol of SLP. Linear mixed modeling methods were used to evaluate the effects of age, axial length, TSS, and corneal birefringence on RNFL measurements. One randomly selected eye of 48 subjects from the cohort underwent 3 serial scans during the same session to determine the repeatability. Age significantly influenced all RNFL measurements. RNFL measurements decreased by 1 µm for every decade increase in age. TSS affected the overall average RNFL measurement (β=-0.62, P=0.003), whereas residual anterior segment retardance affected the superior quadrant measurement (β=1.14, P=0.01). Axial length and corneal birefringence measurements did not influence RNFL measurements. Repeatability, as assessed by the coefficient of variation, ranged between 1.7% for the overall average RNFL measurement and 11.4% for th nerve fiber indicator. Age significantly affected all RNFL measurements with the ECC protocol of SLP, whereas TSS and residual anterior segment retardance affected the overall average and the superior average RNFL measurements, respectively. Axial length and corneal birefringence measurements did not influence any RNFL measurements. RNFL measurements had good intrasession repeatability. These results are important while evaluating the change in structural measurements over time in glaucoma patients.

  14. Contrast-enhanced power Doppler US in the characterization of renal masses

    International Nuclear Information System (INIS)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E.

    2000-01-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts [it

  15. Comparison of neuroendocrine tumor detection and characterization using DOTATOC-PET in correlation with contrast enhanced CT and delayed contrast enhanced MRI

    International Nuclear Information System (INIS)

    Giesel, F.L.; Kratochwil, C.; Mehndiratta, A.; Wulfert, S.; Moltz, J.H.; Zechmann, C.M.; Kauczor, H.U.; Haberkorn, U.; Ley, S.

    2012-01-01

    Purpose: We evaluated the rate of successful characterization of gastroenteropancreatic neuroendocrine tumors (NETs) present with an increased somatostatin receptor, comparing CE-CT with CE-MRI, each in correlation with DOTATOC-PET. Methods and materials: 8 patients with GEP-NET were imaged using CE-MRI (Gd-EOB-DTPA), CE-CT (Imeron 400) and DOTATOC-PET. Contrast-enhancement of normal liver-tissue and metastasis was quantified with ROI-technique. Tumor delineation was assessed with visual-score in blind-read-analysis by two experienced radiologists. Results: Out of 40 liver metastases in patients with NETs, all were detected by CE-MRI and the lesion extent could be adequately assessed, whereas CT failed to detect 20% of all metastases. The blind-read-score of CT in arterial and portal phase was median −0.65 and −1.4, respectively, and 2.7 for delayed-MRI. The quantitative ROI-analysis presented an improved contrast-enhancement-ratio with a median of 1.2, 1.6 and 3.3 for CE-CT arterial, portal-phase and delayed-MRI respectively. Conclusion: Late CE-MRI was superior to CE-CT in providing additionally morphologic characterization and exact lesion extension of hepatic metastases from neuroendocrine tumor detected with DOTATOC-PET. Therefore, late enhanced Gd-EOB-DTPA-MRI seems to be the adequate imaging modality for combination with DOTATOC-PET to provide complementary (macroscopic and molecular) tumor characterization in hepatic metastasized NETs

  16. Value of fusion of PET and MRI in the detection of intra-pelvic recurrence of gynecological tumor: comparison with 18F-FDG contrast-enhanced PET/CT and pelvic MRI.

    Science.gov (United States)

    Kitajima, Kazuhiro; Suenaga, Yuko; Ueno, Yoshiko; Kanda, Tomonori; Maeda, Tetsuo; Makihara, Natsuko; Ebina, Yasuhiko; Yamada, Hideto; Takahashi, Satoru; Sugimura, Kazuro

    2014-01-01

    To evaluate the diagnostic value of retrospective image fusion from pelvic magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose positron emission tomography (PET) in detecting intra-pelvic recurrence of gynecological tumor. Thirty patients with a suspicion of recurrence of gynecological malignancy underwent inline contrast-enhanced PET/computed tomography (CT) and pelvic contrast-enhanced MRI for restaging. Diagnostic performance about the local recurrence, pelvic lymph node and bone metastasis and peritoneal lesion of PET/low-dose non-enhanced CT (PET/ldCT), PET/full-dose contrast-enhanced CT (PET/ceCT), contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) were evaluated by two experienced readers. Final diagnoses were obtained by histopathological examinations, radiological imaging and clinical follow-up for at least 6 months. McNemar test was employed for statistical analysis. Documented positive locally recurrent disease, pelvic lymph node and bone metastases, and peritoneal dissemination were present in 53.3, 26.7, 10.0, and 16.7%, respectively. Patient-based sensitivity for detecting local recurrence, pelvic lymph node and bone metastasis and peritoneal lesion were 87.5, 87.5, 100 and 80.0%, respectively, for fused PET/MRI, 87.5, 62.5, 66.7 and 60.0%, respectively, for contrast-enhanced MRI, 62.5, 87.5, 66.7 and 80.0%, respectively, for PET/ceCT, and 50.0, 87.5, 66.7 and 60.0%, respectively, for PET/ldCT. The sensitivity of diagnosing local recurrence by fused PET/MRI was significantly better than that of PET/ldCT (p=0.041). The patient-based sensitivity, specificity and accuracy for the detection of intra-pelvic recurrence/metastasis were 91.3, 100 and 93.3% for fused PET/MRI, 82.6, 100 and 86.7% for contrast-enhanced MRI, 82.6, 100 and 86.7% for PET/ceCT and 78.3, 85.7 and 80.0% for PET/ldCT. Fused PET/MRI combines the individual advantages of MRI and PET, and is a valuable technique for assessment of intra

  17. FUZZY BASED CONTRAST STRETCHING FOR MEDICAL IMAGE ENHANCEMENT

    Directory of Open Access Journals (Sweden)

    T.C. Raja Kumar

    2011-07-01

    Full Text Available Contrast Stretching is an important part in medical image processing applications. Contrast is the difference between two adjacent pixels. Fuzzy statistical values are analyzed and better results are produced in the spatial domain of the input image. The histogram mapping produces the resultant image with less impulsive noise and smooth nature. The probabilities of gray values are generated and the fuzzy set is determined from the position of the input image pixel. The result indicates the good performance of the proposed fuzzy based stretching. The inverse transform of the real values are mapped with the input image to generate the fuzzy statistics. This approach gives a flexible image enhancement for medical images in the presence of noises.

  18. Colorectal liver metastases: contrast agent diffusion coefficient for quantification of contrast enhancement heterogeneity at MR imaging.

    Science.gov (United States)

    Jia, Guang; O'Dell, Craig; Heverhagen, Johannes T; Yang, Xiangyu; Liang, Jiachao; Jacko, Richard V; Sammet, Steffen; Pellas, Theodore; Cole, Patricia; Knopp, Michael V

    2008-09-01

    To describe and determine the reproducibility of a simplified model to quantitatively measure heterogeneous intralesion contrast agent diffusion in colorectal liver metastases. This HIPAA-compliant retrospective study received institutional review board approval, and written informed consent was obtained from 14 patients (mean age, 61 years +/- 9 [standard deviation]; range, 41-78 years), including 10 men (mean age, 65 years +/- 8; range, 47-78 years) and four women (mean age, 54 years +/- 9; range, 41-59 years), with colorectal liver metastases. Magnetic resonance (MR) imaging was performed twice (first baseline MR image [B(1)] and second baseline MR image [B(2)]) in a single target lesion prior to therapy. Dynamic contrast material-enhanced MR imaging was performed by using a saturation-recovery fast gradient-echo sequence. A simplified contrast agent diffusion model was proposed, and a contrast agent diffusion coefficient (CDC) was calculated. The reproducibility of the CDC measurement was evaluated by using the Bland-Altman plot and a linear regression model. The mean CDC was 0.22 mm(2)/sec (range, 0.01-0.73 mm(2)/sec) on B(1) and 0.24 mm(2)/sec (range, 0.01-0.71 mm(2)/sec) on B(2), with an intraclass correlation coefficient of 0.91 (P < .0001). Bland-Altman plot showed good agreement, with a mean difference in measurement pairs of 0.017 mm(2)/sec +/- 0.096. The slope from the linear regression model was 0.89 (95% confidence interval: 0.63, 1.15) and the intercept was 0.01 (95% confidence interval: -0.08, 0.09). The CDC enables a quantitative description of contrast enhancement heterogeneity in lesions. Given the high reproducibility of the CDC metric, CDC appears promising for further qualification as an imaging biomarker of change measurement in response assessment. http://radiology.rsnajnls.org/cgi/content/full/248/3/901/DC1. RSNA, 2008

  19. Comparison of morphological and kinetic parameters in distinction of benign and malignant breast lesions in dynamic contrast enhanced magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Direnç Özlem Aksoy

    2013-12-01

    Full Text Available Objective: To evaluate the value of qualitative morphologicaland kinetic data and quantitative kinetic data indistinction of malignancy in dynamic contrast enhancedmagnetic resonance imaging (DCE-MRI of the breast.Methods: DCE-MRIs of 49 subjects were evaluated.Morphological and contrast enhancement parameters of95 lesions were recorded in these subjects. Post-contrastkinetic behavior of these lesions were also investigated.Among the quantitative parameters, relative enhancements(E1, E2, Epeak, time-to-peak (Tpeak, slope ofcurve (Slope, signal enhancement ratio (SER, and maximumintensity time ratio (MITR were calculated. Theseresults were compared with the pathological diagnosis.Results: Spiculated contour (100%, rim enhancement(97.87%, irregular shape (95.74%, and irregular margin(91.49% were the most specific morphological featuresof malignancy in mass lesions. In non-mass lesions, focalzone (91.49% was the most specific feature of malignancy.74.5% of the benign lesions showed type 1, 77.1%of the malignant lesions showed type 2 and 3 curves accordingto the kinetic curve evaluation. All quantitativeparameters except Epeak were found to be statisticallysignificant in distinction of malignancy.Conclusion: None of the morphological features of thebenign lesions were found to be significantly specific.More specific features can be described for malignantlesions. Early behavior of the kinetic curve is not usefulfor diagnosis of malignancy but the intermediate and latebehavior gives useful information. Quantitative data involvedin this study might be promising.Key words: Morphological, kinetic, breast lesions, magnetic resonance imaging, dynamic

  20. Contrast-Enhanced MR Imaging of Lymph Nodes in Cancer Patients

    International Nuclear Information System (INIS)

    Choi, Seung Hong; Moon, Woo Kyung

    2010-01-01

    The accurate identification and characterization of lymph nodes by modern imaging modalities has important therapeutic and prognostic significance for patients with newly diagnosed cancers. The presence of nodal metastases limits the therapeutic options, and it generally indicates a worse prognosis for the patients with nodal metastases. Yet anatomic imaging (CT and MR imaging) is of limited value for depicting small metastatic deposits in normal-sized nodes, and nodal size is a poor criterion when there is no extracapsular extension or focal nodal necrosis to rely on for diagnosing nodal metastases. Thus, there is a need for functional methods that can be reliably used to identify small metastases. Contrast-enhanced MR imaging of lymph nodes is a non-invasive method for the analysis of the lymphatic system after the interstitial or intravenous administration of contrast media. Moreover, some lymphotrophic contrast media have been developed and used for detecting lymph node metastases, and this detection is independent of the nodal size. This article will review the basic principles, the imaging protocols, the interpretation and the accuracies of contrast-enhanced MR imaging of lymph nodes in patients with malignancies, and we also focus on the recent issues cited in the literature. In addition, we discuss the results of several pre-clinical studies and animal studies that were conducted in our institution