WorldWideScience

Sample records for subjects underwent contrast-enhanced

  1. Automatized spleen segmentation in non-contrast-enhanced MR volume data using subject-specific shape priors

    Science.gov (United States)

    Gloger, Oliver; Tönnies, Klaus; Bülow, Robin; Völzke, Henry

    2017-07-01

    To develop the first fully automated 3D spleen segmentation framework derived from T1-weighted magnetic resonance (MR) imaging data and to verify its performance for spleen delineation and volumetry. This approach considers the issue of low contrast between spleen and adjacent tissue in non-contrast-enhanced MR images. Native T1-weighted MR volume data was performed on a 1.5 T MR system in an epidemiological study. We analyzed random subsamples of MR examinations without pathologies to develop and verify the spleen segmentation framework. The framework is modularized to include different kinds of prior knowledge into the segmentation pipeline. Classification by support vector machines differentiates between five different shape types in computed foreground probability maps and recognizes characteristic spleen regions in axial slices of MR volume data. A spleen-shape space generated by training produces subject-specific prior shape knowledge that is then incorporated into a final 3D level set segmentation method. Individually adapted shape-driven forces as well as image-driven forces resulting from refined foreground probability maps steer the level set successfully to the segment the spleen. The framework achieves promising segmentation results with mean Dice coefficients of nearly 0.91 and low volumetric mean errors of 6.3%. The presented spleen segmentation approach can delineate spleen tissue in native MR volume data. Several kinds of prior shape knowledge including subject-specific 3D prior shape knowledge can be used to guide segmentation processes achieving promising results.

  2. Diagnostic Accuracy of Detecting Hashimoto's Thyroiditis in Thyroid Cancer Patients Who Underwent Thyroid Surgery: Comparison of Ultrasonography, Positron Emission Tomography/CT, Contrast Enhanced CT, and Anti-Thyroid Antibody

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Gyun; Lee, Tae Hyun; Park, Dong Hee; Nam, Sang Been [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To compare the diagnostic accuracy of ultrasonography (US), F18-fluorodeoxyglucose positron emission tomography/CT (PET/CT), contrast enhanced CT (CECT), serum anti-thyroid antibody for detecting Hashimoto's thyroiditis in thyroid cancer patients who underwent neck surgery. A total of 150 patients with suspicious for thyroid cancer, who had previously undergone US guided needle aspiration of thyroid, were evaluated with the use of US, PET/CT, CECT and serum anti-thyroid antibody. The four studies were performed within two months before neck surgery. Hashimoto's thyroiditis was confirmed by histopathological results. The diagnostic accuracy of US, PET/CT, CECT and serum anti-thyroid antibody were calculated statistically. Hashimoto's thyroiditis was diagnosed in 51 out of the 150 patients, following neck surgery. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of US were 76.5%, 92.9%, 84.8%, 88.5%, and 87.3%, respectively. The corresponding values of PET/CT were 37.3%, 96.0%, 82.6%, 74.8%, and 76.0%, and CECT were 62.7%, 89.9%, 76.2%, 82.4%, and 80.7%, and serum anti-thyroid antibody level were 90.2%, 93.9%, 88.5%, 94.9%, and 92.7%, respectively. McNemar test revealed significant difference among PET/CT and others, but no significant differences among US, CECT and serum anti-thyroid antibody. Overall, serum anti-thyroid antibody showed most accurate diagnostic performance. In detecting Hashimoto's thyroiditis, serum anti-thyroid antibody showed higher diagnostic accuracy than others. US also showed relatively high diagnostic accuracy.

  3. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function.

    Science.gov (United States)

    Park, Sung Yoon; Kim, Chan Kyo; Kim, EunJu; Park, Byung Kwan

    2015-02-01

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88% of right and 92% of left renal arteries, while it was 96% in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82% and 100% for reader 1 and 82% and 95% for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. • Accurate pre-treatment evaluation of renal artery anatomy helps clinical decision-making. • NC-MRA using RAVEL offers acceptable imaging quality for renal artery evaluation. • The 3 T RAVEL technique provides excellent diagnostic performance for renal artery evaluation. • The 3 T RAVEL technique may be an alternative to contrast-enhanced MRA.

  4. Contrast-enhanced Dedicated Breast CT: Initial Clinical Experience1

    Science.gov (United States)

    Prionas, Nicolas D.; Ray, Shonket; Huang, Shih-Ying; Beckett, Laurel A.; Monsky, Wayne L.; Boone, John M.

    2010-01-01

    Purpose: To quantify contrast material enhancement of breast lesions scanned with dedicated breast computed tomography (CT) and to compare their conspicuity with that at unenhanced breast CT and mammography. Materials and Methods: Approval of the institutional review board and the Radiation Use Committee and written informed consent were obtained for this HIPAA-compliant study. Between September 2006 and April 2009, 46 women (mean age, 53.2 years; age range, 35–72 years) with Breast Imaging Reporting and Data System category 4 or 5 lesions underwent unenhanced breast CT and contrast material–enhanced breast CT before biopsy. Two radiologists independently scored lesion conspicuity for contrast-enhanced breast CT versus mammography and for contrast-enhanced breast CT versus unenhanced breast CT. Mean lesion voxel intensity was measured in Hounsfield units and normalized to adipose tissue intensity on manually segmented images obtained before and after administration of contrast material. Regression models focused on conspicuity and quantified enhancement were used to estimate the effect of pathologic diagnosis (benign vs malignant), lesion type (mass vs calcifications), breast density, and interradiologist variability. Results: Fifty-four lesions (25 benign, 29 malignant) in 46 subjects were analyzed. Malignant lesions were seen significantly better at contrast-enhanced breast CT than at unenhanced breast CT (P mammography (P contrast-enhanced breast CT than at unenhanced breast CT (P contrast-enhanced breast CT and mammography. Malignant lesions enhanced 55.9 HU ± 4.0 (standard error), whereas benign lesions enhanced 17.6 HU ± 6.1 (P contrast-enhanced breast CT. Quantifying lesion enhancement may aid in the detection and diagnosis of breast cancer. © RSNA, 2010 PMID:20720067

  5. Fuzzy-Contextual Contrast Enhancement.

    Science.gov (United States)

    Parihar, Anil; Verma, Om; Khanna, Chintan

    2017-02-08

    This paper presents contrast enhancement algorithms based on fuzzy contextual information of the images. We introduce fuzzy similarity index and fuzzy contrast factor to capture the neighborhood characteristics of a pixel. A new histogram, using fuzzy contrast factor of each pixel is developed, and termed as the fuzzy dissimilarity histogram (FDH). A cumulative distribution function (CDF) is formed with normalized values of FDH and used as a transfer function to obtain the contrast enhanced image. The algorithm gives good contrast enhancement and preserves the natural characteristic of the image. In order to develop a contextual intensity transfer function, we introduce a fuzzy membership function based on fuzzy similarity index and coefficient of variation of the image. The contextual intensity transfer function is designed using the fuzzy membership function to achieve final contrast enhanced image. The overall algorithm is referred as the fuzzy contextual contrast-enhancement (FCCE) algorithm. The proposed algorithms are compared with conventional and state-of-art contrast enhancement algorithms. The quantitative and visual assessment of the results is performed. The results of quantitative measures are statistically analyzed using t-test. The exhaustive experimentation and analysis show the proposed algorithm efficiently enhances contrast and yields in natural visual quality images.

  6. Commercialization of vein contrast enhancement

    Science.gov (United States)

    Lovhoiden, Gunnar; Deshmukh, Harshal; Vrancken, Carlos; Zhang, Yong; Zeman, Herbert D.; Weinberg, Devin

    2003-07-01

    An ongoing clinical study of an experimental infrared (IR) device, the Vein Contrast Enhancer (VCE) that visualizes surface veins for medical access, indicates that a commercial device with the performance of the existing VCE would have significant clinical utility for even a very skilled phlebotomist. A proof-of-principle prototype VCE device has now been designed and constructed that captures IR images of surface veins with a commercial CCD camera, transfers the images to a PC for real-time software image processing to enhance the vein contrast, and projects the enhanced images back onto the skin with a modified commercial LCD projector. The camera and projector are mounted on precision slides allowing for precise mechanical alignment of the two optical axes and for measuring the effects of axes misalignment. Precision alignment of the captured and projected images over the entire field-of-view is accomplished electronically by software adjustments of the translation, scaling, and rotation of the enhanced images before they are projected back onto the skin. This proof-of-principle prototype will be clinically tested and the experience gained will lead to the development of a commercial device, OnTarget!, that is compact, easy to use, and will visualize accessible veins in almost all subjects needing venipuncture.

  7. Renal oncocytoma: contrast-enhanced sonographic features.

    Science.gov (United States)

    Wu, Ying; Du, Lianfang; Li, Fan; Zhang, Huiping; Cai, Yingyu; Jia, Xiao

    2013-03-01

    The purpose of this study was to illustrate the features of renal oncocytoma on contrast-enhanced sonography. Five cases of surgical pathologically proven renal oncocytoma were retrospectively reviewed and analyzed in this study. The 5 patients studied included 3 men and 2 women with a mean age of 52.3 years (range, 32-66 years). All patients underwent conventional and contrast-enhanced sonographic examinations before surgery. The sonographic features, enhancement pattern, and dynamic perfusion change of the tumors and renal parenchyma in vascular phases were evaluated and compared to computed tomography. On grayscale sonography, renal oncocytomas appeared as solitary hypoechoic or isoechoic masses originating from the renal cortex measuring 2 to 6 cm with a well-defined margin. Color Doppler flow imaging showed rich blood flow signals in the periphery and striplike blood flow signals within the masses. On contrast-enhanced sonography, the features of these tumors included early enhancement, hyperenhancement, and fast wash-out compared to the adjacent renal cortex. There were irregular nonenhanced areas seen in the center of the masses (n = 3) and nonenhanced thin rims seen in the periphery (n = 5). Macroscopically, the well-marginated tumors were yellowish brown with a tender texture and were located in the renal cortex. Central irregularly shaped fibrous scars were seen in 3 tumors, consistent with nonenhanced areas on contrast-enhanced imaging. Contrast-enhanced sonography can provide valuable hemodynamic information on renal oncocytoma, which may help in making a differential diagnosis of this benign renal tumor in clinical practice.

  8. Contrast-enhanced digital mammography.

    Science.gov (United States)

    Jochelson, Maxine

    2014-05-01

    Mammography is the only technology documented to reduce breast cancer mortality. Its sensitivity, however, is 75% to 80% at best and reduced to 30% to 50% in women with dense breasts. MR imaging is a sensitive modality for the detection of breast cancer but cannot be used in all patients. Its sensitivity is due in large part to its ability to detect enhancement of tumor vascularity so cancers can be detected before a mass is present. Contrast-enhanced dual-energy mammography uses the same capability of vascular enhancement and has been demonstrated to be more sensitive than routine mammography. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Norms of the Mini-Mental state Examination for Japanese subjects that underwent comprehensive brain examinations: the Kashima Scan Study.

    Science.gov (United States)

    Yakushiji, Yusuke; Horikawa, Etsuo; Eriguchi, Makoto; Nanri, Yusuke; Nishihara, Masashi; Hirotsu, Tatsumi; Hara, Hideo

    2014-01-01

    The distribution of the Mini-Mental State Examination (MMSE) scores by age and educational level was investigated in subjects that underwent comprehensive brain examinations. This cross-sectional study included 1,414 adults without neurological disorders who underwent health-screening tests of the brain, referred to as the "Brain Dock," in our center. The MMSE scores were compared between age groups (40-44, 45-49, 50-54, 55-59, 60-64, 65-69, or ≥70 years) and educational levels [the low education level group (6-12 years) and the high education level group (≥13 years)]. The median age was 59 years, and 763 (54%) were women. There was no significant difference in the MMSE total score between women and men. The stepwise method of the multiple linear regression analysis confirmed that a higher age [β value, -0.129; standard error (S.E.), 0.020; p<0.001], low education level (6-12 years) (β value, -0.226; S.E., 0.075; p=0.003), and women (β values, 0.148; S.E., 0.066; p=0.024) was significantly associated with decreased MMSE score. In general, both the percentile scores and mean scores decreased with aging and were lower in the low education level group than in the high education level group. The degree of decrement in scores with age was stronger in the low education level group than in the high education level group. The provided data for age- and education-specific reference norms will be useful for both clinicians and investigators who perform comprehensive brain examinations to assess the cognitive function of subjects.

  10. Contrast-enhanced peripheral MRA

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Thomsen, Henrik S

    2012-01-01

    -state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged......In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast...... MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic...

  11. CT Angiography: Post-processed Contrast Enhancement for Improved Detection of Pulmonary Embolism.

    Science.gov (United States)

    Muenzel, Daniela; Fingerle, Alexander A; Zahel, Tina; Sauter, Andreas; Vlassenbroek, Alain; Dobritz, Martin; Rummeny, Ernst J; Noël, Peter B

    2017-02-01

    The study aimed to improve the detection of pulmonary embolism via an iodine contrast enhancement tool in patients who underwent suboptimal enhanced computed tomography angiography (CTA). We evaluated the CT examinations of 41 patients who underwent CTA for evaluation of the pulmonary arteries which suffered from suboptimal contrast enhancement. The contrast enhancement of the reconstructed images was increased via a post-processing tool (vContrast). Image noise and contrast-to-noise ratio (CNR) were assessed in eight different regions: main pulmonary artery, right and left pulmonary arteries, right and left segment arteries, muscle, subcutaneous fat, and bone. For subjective image assessment, three experienced radiologists evaluated the diagnostic quality. While employing the post-processing algorithm, the CNR for contrast-filled lumen and thrombus/muscle improves significantly by a factor of 1.7 (CNR without vContrast = 8.48 ± 6.79/CNR with vContrast = 14.46 ± 5.29) (P image analysis illustrated a significant improvement using post-processing for clinically relevant criteria such as diagnostic confidence. vContrast makes CT angiograms with inadequate contrast applicable for diagnostic evaluation, offering an improved visualization of the pulmonary arteries. In addition, vContrast can help in the significant reduction of the iodine contrast material. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  12. Contrast-enhanced spectral mammography (CESM) and contrast enhanced MRI (CEMRI): Patient preferences and tolerance.

    Science.gov (United States)

    Hobbs, Max M; Taylor, Donna B; Buzynski, Sebastian; Peake, Rachel E

    2015-06-01

    Contrast-enhanced spectral mammography (CESM) may have similar diagnostic performance to Contrast-enhanced MRI (CEMRI) in the diagnosis and staging of breast cancer. To date, research has focused exclusively on diagnostic performance when comparing these two techniques. Patient experience is also an important factor when comparing and deciding on which of these modalities is preferable. The aim of this study is to compare patient experience of CESM against CEMRI during preoperative breast cancer staging. Forty-nine participants who underwent both CESM and CEMRI, as part of a larger trial, completed a Likert questionnaire about their preference for each modality according to the following criteria: comfort of breast compression, comfort of intravenous (IV) contrast injection, anxiety and overall preference. Participants also reported reasons for preferring one modality to the other. Quantitative data were analysed using a Wilcoxon sign-rank test and chi-squared test. Qualitative data are reported descriptively. A significantly higher overall preference towards CESM was demonstrated (n = 49, P contrast injection (n = 49, P = 0.003). Our data suggest that overall, patients prefer the experience of CESM to CEMRI, adding support for the role of CESM as a possible alternative to CEMRI for breast cancer staging. © 2015 The Royal Australian and New Zealand College of Radiologists.

  13. Contrast enhancement versus vasculature of uterine tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kormano, M.; Kiilholma, P.; Groenroos, M.

    1984-05-01

    The relative contrast enhancement of normal myometrium and small or medium size uterine fibroids and clinical stage I endometrial carcinomas were correlated to their microangiographically demonstrable vascularity. In four cases small uterine fibroids showed contrast enhancement equal to normal myometrium, independent of their vascularity in microangiography. In five, endometrial carcinomas contrast enhancement was always below that of the surrounding myometrium in CT. Intratumour vasculature showed great variability in microangiography. No correlation between the topographic variations in the arrangement or density of tumour blood vessels and the degree of contrast enhancement was found. Contrast enhancement of small uterine fibroids was greater than that of small adenocarcinomas. More contrast material accumulates into the extravascular space of the smooth muscle tissue of the fibroid than into the extravascular space of endometrial carcinoma.

  14. Use of contrast-enhanced ultrasonography to characterize adrenal gland tumors in dogs.

    Science.gov (United States)

    Pey, Pascaline; Rossi, Federica; Vignoli, Massimo; Duchateau, Luc; Marescaux, Laurent; Saunders, Jimmy H

    2014-10-01

    To describe the contrast-enhanced ultrasonographic characteristics and vascular patterns of adrenal gland tumors in dogs and determine whether those features are indicative of malignancy or histologic type of tumor. 14 dogs with 16 adrenal gland lesions (10 carcinomas [8 dogs], 3 adenomas [3 dogs], and 3 pheochromocytomas [3 dogs]). Unsedated dogs with adrenal gland lesions underwent B-mode ultrasonography and contrast-enhanced ultrasonography ≤ 48 hours before adrenalectomy; contrast-enhanced ultrasonographic examinations were video-recorded. Macroscopic evaluation of the adrenal gland lesions and histologic examination of removed adrenal gland tissues were subsequently performed. Surgical and histopathologic findings and the ultrasonographic and contrast-enhanced ultrasonographic characteristics were recorded for the various tumor types. Time-intensity curves were generated from the contrast-enhanced ultrasonographic recordings and used to calculate regional blood volume (value proportional to area under the curve) and mean transit time (time the lesion began to enhance to the half-peak intensity). In adrenal gland carcinomas, tortuous feeding vessels were noticeable during the arterial and venous phases of contrast enhancement. Heterogeneity of contrast enhancement was evident only in malignant tumors. Compared with adenomas, adrenal gland carcinomas and pheochromocytomas had significantly less regional blood volume. Mean transit times were significantly shorter in adrenal gland carcinomas and pheochromocytomas than in adenomas. For dogs, evaluation of the vascular pattern and contrast-enhancement characteristics of adrenal gland tumors by means of contrast-enhanced ultrasonography may be useful in assessment of malignancy and tumor type.

  15. Post-traumatic contrast enhancing brain lesion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Jung; Kim, Hyun Sook; Jeong, Min Sun; Kim, Deok Ryeong; Cho, Young Kwon; Choi, Yun Sun [Eulji Hospital, Eulji University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    Only a few studies have been reported on the MR contrast enhancement and the apparent diffusion coefficient (ADC) findings of the post-traumatic lesion of the brain. We report a case of the venous ischemia in the left frontal lobe observed in the MRI obtained one day after the incidence of trauma. Considering the presented slight increase in the ADC, the vasogenic edema was thought to be the major mechanism of the venous ischemia and excitotoxic injury. In spite of a slight increase in the ADC, the hyperintensity in the diffusion weighted imaging and contrast-enhanced areas eventually changed into hemorrhagic lesions.

  16. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  17. Dynamic Contrast-Enhanced Magnetic Resonance Enterography and Dynamic Contrast-Enhanced Ultrasonography in Crohn's Disease

    DEFF Research Database (Denmark)

    Wilkens, Rune; Peters, David A; Nielsen, Agnete Hedemann

    2017-01-01

    Purpose e Cross-sectional imaging methods are important for objective evaluationof small intestinal inflammationinCrohn'sdisease(CD).The primary aim was to compare relative parameters of intestinal perfusion between contrast-enhanced ultrasonography (CEUS) and dynamic contrast-enhanced magnetic...

  18. Polycystic ovary syndrome: dynamic contrast-enhanced ovary MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, C. Zuhal E-mail: sunarerdem@yahoo.com; Bayar, Ulku; Erdem, L. Oktay; Barut, Aykut; Gundogdu, Sadi; Kaya, Erdal

    2004-07-01

    Objective: to determine the enhancement behaviour of the ovaries in women with polycystic ovary syndrome (PCOS) by dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging and to compare these data with those of normal ovulating controls. Method: 24 women with PCOS and 12 controls underwent DCE-MR imaging. Dynamic images were acquired before and after injection of a contrast bolus at 30 s and the min of 1, 2, 3, 4 and 5. On postprocessing examination: (i) the ovarian volumes; (ii) the signal intensity value of each ovary per dynamic study; (iii) early-phase enhancement rate; (iv) time to peak enhancement (T{sub p}); and (v) percentage of washout of 5th min were determined. Data of the ovaries of the women with PCOS and controls were compared with Mann-Whitney U-test. Results: the mean values of T{sub p} were found to be significantly lower in women with PCOS than in controls (p<0.05). On the other hand, the mean values of ovarian volume, the early-phase enhancement rate, and percentage of washout of 5th min of ovaries were significantly higher in PCOS patients (p<0.05). Examination of the mean signal intensity-time curve revealed the ovaries in women with PCOS showed a faster and greater enhancement and wash-out. Conclusion: the enhancement behaviour of ovaries of women with PCOS may be significantly different from those of control subjects on DCE-MR imaging examination. In our experience, it is a valuable modality to highlight the vascularization changes in ovarian stroma with PCOS. We believe that improved DCE-MR imaging techniques may also provide us additional parameters in the diagnosis and treatment strategies of PCOS.

  19. Clinical evaluation of contrast-enhanced digital mammography and contrast enhanced tomosynthesis--Comparison to contrast-enhanced breast MRI.

    Science.gov (United States)

    Chou, Chen-Pin; Lewin, John M; Chiang, Chia-Ling; Hung, Bao-Hui; Yang, Tsung-Lung; Huang, Jer-Shyung; Liao, Jia-Bin; Pan, Huay-Ben

    2015-12-01

    To compare the diagnostic accuracy of contrast-enhanced digital mammography (CEDM) and contrast-enhanced tomosynthesis (CET) to dynamic contrast enhanced breast MRI (DCE-MRI) using a multireader-multicase study. Institutional review board approval and informed consents were obtained. Total 185 patients (mean age 51.3) with BI-RADS 4 or 5 lesions were evaluated before biopsy with mammography, tomosynthesis, CEDM, CET and DCE-MRI. Mediolateral-oblique and cranio-caudal views of the target breast CEDM and CET were acquired at 2 and 4 min after contrast agent injection. A mediolateral-oblique view of the non-target breast was taken at 6 min. Each lesion was scored with forced BI-RADS categories by three readers. Each reader interpreted lesions in the following order: mammography, tomosynthesis, CEDM, CET, and DCE-MRI during a single reading session. Histology showed 81 cancers and 144 benign lesions in the study. Of the 81 malignant lesions, 44% (36/81) were invasive and 56% (45/81) were non-invasive. Areas under the ROC curve, averaged for the 3 readers, were as follows: 0.897 for DCE-MRI, 0.892 for CET, 0.878 for CEDM, 0.784 for tomosynthesis and 0.740 for mammography. Significant differences in AUC were found between the group of contrast enhanced modalities (CEDM, CET, DCE-MRI) and the unenhanced modalities (all p0.05). CET and CEDM may be considered as an alternative modality to MRI for following up women with abnormal mammography. All three contrast modalities were superior in accuracy to conventional digital mammography with or without tomosynthesis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Dose optimization of contrast-enhanced carotid MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Unterweger, M.; Froehlich, J.M.; Kubik-Huch, R.A.; Seifert, B.; Birrer, M.; Huber, T.; Otto, R. [Institute of Radiology, Cantonal Hospital Baden, Baden (Switzerland)

    2005-09-01

    The purpose of this work was to compare the diagnostic performance of a single-contrast or a double-contrast dose of carotid contrast-enhanced MR angiography (MRA). One-hundred nineteen patients (mean age 65{+-}14.4 years) underwent carotid contrast-enhanced MRA with a standardized protocol (repetition time/echo 3.73 ms/1.38 ms, flip-angle 25 , acquisition-time 19 s, voxel size 1.2 x 1.2 x 0.9 mm{sup 3}) on a 1.5-T scanner (Sonata, Siemens-Medical-Systems) using a neck phased-array coil. Contrast agent was administered intravenously at a rate of 3.0 ml/s, either as a single dose (n=57; 0.1 mmol/kg body weight) or as a double dose (n=62; 0.2 mmol/kg body weight) of meglumine gadoterate (0.5 M/l), followed by 30 ml saline. Qualitative image analysis was performed on maximum intensity projections using a five-point scale. Signal intensities were measured at three different vascular levels on both sides to assess the contrast-to-noise ratios (CNRs). Image quality was rated as good or excellent in all cases. A double dose did not influence the efficacy of carotid enhancement (CNR single dose 69.12{+-}19.8; CNR double dose 70.01{+-}20.7; p=0.81) compared with a single dose. In both dose groups the mean CNRs were inversely related to bodyweight, despite adjusted contrast volumes (p=0.0005). Double-dose contrast-enhanced carotid MRA is not superior to single-dose MRA, as overall diagnostic performance and quantitative contrast enhancement are equal. Being more cost-efficient, a single-dose administration of contrast agent is recommended for MRA of the carotid arteries. (orig.)

  1. Dual-energy contrast-enhanced mammography.

    Science.gov (United States)

    Travieso Aja, M M; Rodríguez Rodríguez, M; Alayón Hernández, S; Vega Benítez, V; Luzardo, O P

    2014-01-01

    The degree of vascularization in breast lesions is related to their malignancy. For this reason, functional diagnostic imaging techniques have become important in recent years. Dual-energy contrast-enhanced mammography is a new, apparently promising technique in breast cancer that provides information about the degree of vascularization of the lesion in addition to the morphological information provided by conventional mammography. This article describes the state of the art for dual-energy contrast-enhanced mammography. Based on 15 months' clinical experience, we illustrate this review with clinical cases that allow us to discuss the advantages and limitations of this technique. Copyright © 2014 SERAM. Published by Elsevier Espana. All rights reserved.

  2. Evaluation of contrast-enhanced digital mammography.

    Science.gov (United States)

    Diekmann, Felix; Freyer, Martin; Diekmann, Susanne; Fallenberg, Eva M; Fischer, Thomas; Bick, Ulrich; Pöllinger, Alexander

    2011-04-01

    The goal of this prospective study was to evaluate the possible diagnostic benefits of contrast-enhanced digital mammography (CEDM) over conventional mammography. Our analysis included data from 70 patients with a total of 80 lesions (30 malignant and 50 benign). A series of contrast-enhanced images was acquired from each patient using a modified imaging system (GE Senographe 2000D with copper filter) suitable for displaying iodine contrast medium. After the mask image had been taken, the contrast medium was administered using a dosage of 1ml/kg body weight at a rate of 4ml/s. Three contrast-enhanced images in the cranio-caudal projection plane were then captured at intervals of 60s. The mask image was logarithmically subtracted from the contrast-enhanced images. We performed a ROC analysis of diagnostic quality with three readers. On average, 5.66 more malignant lesions were detected with the addition of digital dynamic contrast mammography versus conventional mammography alone. The sensitivity was increased from an average of 0.43 in conventional mammography to an average of 0.62 with contrast mammography. Even in dense breast parenchyma, the sensitivity increased from an average of 0.35-0.59. In the multi-reader-ROC analyses of all readers, the differences in the AUC with p=0.02 (BI-RADS) proved statistically significant in all cases. The Wilcoxon test showed that Readers I and II primarily used the CEDM to upgrade enhancing lesions to a higher BI-RADS category or a higher probability of malignancy. These two readers benefited most from the CEDM in the ROC analysis. Overall, we conclude that the addition of dynamic digital subtraction mammography to conventional mammography can significantly improve diagnostic quality. The increased sensitivity is particularly pronounced in the case of dense breast tissue. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  3. Dynamic Contrast-Enhanced Digital Breast Tomosynthesis

    Science.gov (United States)

    2013-03-01

    500 or secretions due to pathological activity and can be precursors to breast cancers such as ductal carcinoma22, 23. Breast microcalcifications ... Breast Cancer Screening. Am J Med, in press. 650 2Gilles R, Meunier M, Lucidarme O, et al. (1996) Clustered breast microcalcifications : Evaluation... Breast Cancer , contrast-enhanced imaging, digital breast tomosynthesis, dynamic imaging, x-ray imaging 15. Number of Pages (count all pages

  4. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moselewski, Fabian [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Ferencik, Maros [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Achenbach, Stephan [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Internal Medicine II (Cardiology), University of Erlangen (Germany); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Booth, Sarah L. [Jean Mayer USDA Human Nutrition Research Center on Aging, 711 Washington St., Boston, MA 02114 (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)]. E-mail: uhoffman@partners.org

    2006-03-15

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM] at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 {+-} 68.7 HU versus 295 {+-} 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

  5. Dynamic contrast enhanced ultrasound for therapy monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, John M. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Williams, Ross [Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Tremblay-Darveau, Charles; Sheeran, Paul S. [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Milot, Laurent [Department of Medical Imaging, University of Toronto, Toronto, ON (Canada); Bjarnason, Georg A. [Department of Medical Oncology, University of Toronto, and Sunnybrook Odette Cancer Centre, Toronto, ON (Canada); Burns, Peter N., E-mail: burns@sri.utoronto.ca [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Imaging Research, Sunnybrook Research Institute, Toronto, ON (Canada); Department of Medical Imaging, University of Toronto, Toronto, ON (Canada)

    2015-09-15

    Quantitative imaging is a crucial component of the assessment of therapies that target the vasculature of angiogenic or inflamed tissue. Dynamic contrast-enhanced ultrasound (DCE-US) using microbubble contrast offers the advantages of being sensitive to perfusion, non-invasive, cost effective and well suited to repeated use at the bedside. Uniquely, it employs an agent that is truly intravascular. This papers reviews the principles and methodology of DCE-US, especially as applied to anti-angiogenic cancer therapies. Reproducibility is an important attribute of such a monitoring method: results are discussed. More recent technical advances in parametric and 3D DCE-US imaging are also summarised and illustrated.

  6. Osteoblastic Metastases Mimickers on Contrast Enhanced CT

    Directory of Open Access Journals (Sweden)

    Fahad Al-Lhedan

    2017-01-01

    Full Text Available Secondary osseous involvement in lymphoma is more common compared to primary bone lymphoma. The finding of osseous lesion can be incidentally discovered during the course of the disease. However, osseous metastases are infrequently silent. Detection of osseous metastases is crucial for accurate staging and optimal treatment planning of lymphoma. The aim of imaging is to identify the presence and extent of osseous disease and to assess for possible complications such as pathological fracture of the load-bearing bones and cord compression if the lesion is spinal. We are presenting two patients with treated lymphoma who were in complete remission. On routine follow-up contrast enhanced CT, there were new osteoblastic lesions in the spine worrisome for metastases. Additional studies were performed for further evaluation of both of them which did not demonstrate any corresponding suspicious osseous lesion. The patients have a prior history of chronic venous occlusive thrombosis that resulted in collaterals formation. Contrast enhancement of the vertebral body marrow secondary to collaterals formation and venous flow through the vertebral venous plexus can mimic the appearance of spinal osteoblastic metastases.

  7. Contrast enhanced ultrasound of sentinel lymph nodes

    Directory of Open Access Journals (Sweden)

    XinWu Cui

    2013-03-01

    Full Text Available Sentinel lymph nodes are the first lymph nodes in the region that receive lymphatic drainage from a primary tumor. The detection or exclusion of sentinel lymph node micrometastases is critical in the staging of cancer, especially breast cancer and melanoma because it directly affects patient’s prognosis and surgical management. Currently, intraoperative sentinel lymph node biopsies using blue dye and radioisotopes are the method of choice for the detection of sentinel lymph node with high identification rate. In contrast, conventional ultrasound is not capable of detecting sentinel lymph nodes in most cases. Contrast enhanced ultrasound with contrast specific imaging modes has been used for the evaluation and diagnostic work-up of peripherally located suspected lymphadenopathy. The method allows for real-time analysis of all vascular phases and the visualization of intranodal focal “avascular” areas that represent necrosis or deposits of neoplastic cells. In recent years, a number of animal and human studies showed that contrast enhanced ultrasound can be also used for the detection of sentinel lymph node, and may become a potential application in clinical routine. Several contrast agents have been used in those studies, including albumin solution, hydroxyethylated starch, SonoVue®, Sonazoid® and Definity®. This review summarizes the current knowledge about the use of ultrasound techniques in detection and evaluation of sentinel lymph node.

  8. Fast mutual-information-based contrast enhancement

    Science.gov (United States)

    Cao, Gang; Yu, Lifang; Tian, Huawei; Huang, Xianglin; Wang, Yongbin

    2017-07-01

    Recently, T. Celik proposed an effective image contrast enhancement (CE) method based on spatial mutual information and PageRank (SMIRANK). According to the state-of-the-art evaluation criteria, it achieves the best visual enhancement quality among existing global CE methods. However, SMIRANK runs much slower than the other counterparts, such as histogram equalization (HE) and adaptive gamma correction. Low computational complexity is also required for good CE algorithms. In this paper, we novelly propose a fast SMIRANK algorithm, called FastSMIRANK. It integrates both spatial and gray-level downsampling into the generation of pixel value mapping function. Moreover, the computation of rank vectors is speeded up by replacing PageRank with a simple yet efficient row-based operation of mutual information matrix. Extensive experimental results show that the proposed FastSMIRANK could accelerate the processing speed of SMIRANK by about 20 times, and is even faster than HE. Comparable enhancement quality is preserved simultaneously.

  9. Medial tibial pain: a dynamic contrast-enhanced MRI study.

    Science.gov (United States)

    Mattila, K T; Komu, M E; Dahlström, S; Koskinen, S K; Heikkilä, J

    1999-09-01

    The purpose of this study was to compare the sensitivity of different magnetic resonance imaging (MRI) sequences to depict periosteal edema in patients with medial tibial pain. Additionally, we evaluated the ability of dynamic contrast-enhanced imaging (DCES) to depict possible temporal alterations in muscular perfusion within compartments of the leg. Fifteen patients with medial tibial pain were examined with MRI. T1-, T2-weighted, proton density axial images and dynamic and static phase post-contrast images were compared in ability to depict periosteal edema. STIR was used in seven cases to depict bone marrow edema. Images were analyzed to detect signs of compartment edema. Region-of-interest measurements in compartments were performed during DCES and compared with controls. In detecting periosteal edema, post-contrast T1-weighted images were better than spin echo T2-weighted and proton density images or STIR images, but STIR depicted the bone marrow edema best. DCES best demonstrated the gradually enhancing periostitis. Four subjects with severe periosteal edema had visually detectable pathologic enhancement during DCES in the deep posterior compartment of the leg. Percentage enhancement in the deep posterior compartment of the leg was greater in patients than in controls. The fast enhancement phase in the deep posterior compartment began slightly slower in patients than in controls, but it continued longer. We believe that periosteal edema in bone stress reaction can cause impairment of venous flow in the deep posterior compartment. MRI can depict both these conditions. In patients with medial tibial pain, MR imaging protocol should include axial STIR images (to depict bone pathology) with T1-weighted axial pre and post-contrast images, and dynamic contrast enhanced imaging to show periosteal edema and abnormal contrast enhancement within a compartment.

  10. Dynamic contrast-enhanced magnetic resonance imaging of the wrist in children with juvenile idiopathic arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Nusman, Charlotte M. [Emma Children' s Hospital, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Academic Medical Center, Amsterdam (Netherlands); Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Lavini, Cristina; Hemke, Robert; Caan, Matthan W.A.; Maas, Mario [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Schonenberg-Meinema, Dieneke; Berg, J.M. van den; Kuijpers, Taco W. [Emma Children' s Hospital, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Academic Medical Center, Amsterdam (Netherlands); Dolman, Koert M. [Sint Lucas Andreas Hospital, Department of Pediatrics, Amsterdam (Netherlands); Reade Institute location Jan van Breemen, Department of Pediatric Rheumatology, Amsterdam (Netherlands); Rossum, Marion A.J. van [Reade Institute location Jan van Breemen, Department of Pediatric Rheumatology, Amsterdam (Netherlands); Emma Children' s Hospital, Department of Pediatrics, Academic Medical Center, Amsterdam (Netherlands)

    2017-02-15

    Dynamic contrast-enhanced MRI provides information on the heterogeneity of the synovium, the primary target of disease in children with juvenile idiopathic arthritis (JIA). To evaluate the feasibility of dynamic contrast-enhanced MRI in the wrist of children with JIA using conventional descriptive measures and time-intensity-curve shape analysis. To explore the association between enhancement characteristics and clinical disease status. Thirty-two children with JIA and wrist involvement underwent dynamic contrast-enhanced MRI with movement-registration and were classified using validated criteria as clinically active (n = 27) or inactive (n = 5). Outcome measures included descriptive parameters and the classification into time-intensity-curve shapes, which represent the patterns of signal intensity change over time. Differences in dynamic contrast-enhanced MRI outcome measures between clinically active and clinically inactive disease were analyzed and correlation with the Juvenile Arthritis Disease Activity Score was determined. Comprehensive evaluation of disease status was technically feasible and the quality of the dynamic dataset was improved by movement registration. The conventional descriptive measure maximum enhancement differed significantly between clinically active and inactive disease (P = 0.019), whereas time-intensity-curve shape analysis showed no differences. Juvenile Arthritis Disease Activity Score correlated moderately with enhancing volume (P = 0.484). Dynamic contrast-enhanced MRI is a promising biomarker for evaluating disease status in children with JIA and wrist involvement. Conventional descriptive dynamic contrast-enhanced MRI measures are better associated with clinically active disease than time-intensity-curve shape analysis. (orig.)

  11. Nonlinear contrast enhancement on subtraction images

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Keon Il; Jin, Yeun Hwa [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Wonkwang University, Yongin (Korea, Republic of)

    1997-08-15

    This study was performed to demonstrate the effect of linear or nonlinear contrast enhancement on subtraction images. Three different textures were radiographed on dental film. The first radiograph was taken without the presence of an object. The second, which showed trabucular bone, was taken of the molar area of a human. the third radiograph was taken of the coronal part of molars. Each film was digitized into a 1312 x 1024 pixel x 8 bit depth matrix by means of a Nikon 35 mm film scanner(LS-3510AF, Japan) with fixed gain and internal dark current correction to maintain constant illumination. The scanner was interfaced to a Macintosh LC III computer(Apple Computer, Charlotte, N.C.). This resulted in three pairs of images, including different textures-plain, bone and enamel. Digital regular, linearly and nonlinearly enhanced subtraction was performed. Computer software was used to simulate lesions in the shape of a 2D-Gaussian curve on each of a pair of images. The each subtraction images were presented in a random sequence to two groups of 10 observers(students and dentists). ROC analysis was used to compare observer performance. The following results were obtained; 1. All of LCE subtraction, equalized subtraction and regular subtraction images of plain texture were diagnosed the best by far. 2. The data revealed a significant LCE effect in both the student group and the expert group. 3. Clinical expertise was a helpful factor for the observers in this study.

  12. Dynamic contrast enhanced MRI in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Alonzi, Roberto [Marie Curie Research Wing, Mount Vernon Cancer Centre, Rickmansworth Road, Northwood, Middlesex, HA6 2RN (United Kingdom)], E-mail: robertoalonzi@btinternet.com; Padhani, Anwar R. [Paul Strickland Scanner Centre, Mount Vernon Cancer Centre, Rickmansworth Road, Northwood, Middlesex, HA6 2RN (United Kingdom); Synarc Inc. 575 Market Street, San Francisco, CA 94105 (United States)], E-mail: anwar.padhani@paulstrickland-scannercentre.org.uk; Allen, Clare [Department of Imaging, University College Hospital, London, 235 Euston Road, NW1 2BU (United Kingdom)], E-mail: clare.allen@uclh.nhs.uk

    2007-09-15

    Angiogenesis is an integral part of benign prostatic hyperplasia (BPH), is associated with prostatic intraepithelial neoplasia (PIN) and is key to the growth and for metastasis of prostate cancer. Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) using small molecular weight gadolinium chelates enables non-invasive imaging characterization of tissue vascularity. Depending on the technique used, data reflecting tissue perfusion, microvessel permeability surface area product, and extracellular leakage space can be obtained. Two dynamic MRI techniques (T{sub 2}*-weighted or susceptibility based and T{sub 1}-weighted or relaxivity enhanced methods) for prostate gland evaluations are discussed in this review with reference to biological basis of observations, data acquisition and analysis methods, technical limitations and validation. Established clinical roles of T{sub 1}-weighted imaging evaluations will be discussed including lesion detection and localisation, for tumour staging and for the detection of suspected tumour recurrence. Limitations include inadequate lesion characterisation particularly differentiating prostatitis from cancer, and in distinguishing between BPH and central gland tumours.

  13. Contrast-enhanced and targeted ultrasound

    Science.gov (United States)

    Postema, Michiel; Gilja, Odd Helge

    2011-01-01

    Ultrasonic imaging is becoming the most popular medical imaging modality, owing to the low price per examination and its safety. However, blood is a poor scatterer of ultrasound waves at clinical diagnostic transmit frequencies. For perfusion imaging, markers have been designed to enhance the contrast in B-mode imaging. These so-called ultrasound contrast agents consist of microscopically small gas bubbles encapsulated in biodegradable shells. In this review, the physical principles of ultrasound contrast agent microbubble behavior and their adjustment for drug delivery including sonoporation are described. Furthermore, an outline of clinical imaging applications of contrast-enhanced ultrasound is given. It is a challenging task to quantify and predict which bubble phenomenon occurs under which acoustic condition, and how these phenomena may be utilized in ultrasonic imaging. Aided by high-speed photography, our improved understanding of encapsulated microbubble behavior will lead to more sophisticated detection and delivery techniques. More sophisticated methods use quantitative approaches to measure the amount and the time course of bolus or reperfusion curves, and have shown great promise in revealing effective tumor responses to anti-angiogenic drugs in humans before tumor shrinkage occurs. These are beginning to be accepted into clinical practice. In the long term, targeted microbubbles for molecular imaging and eventually for directed anti-tumor therapy are expected to be tested. PMID:21218081

  14. Contrast-enhanced and targeted ultrasound.

    Science.gov (United States)

    Postema, Michiel; Gilja, Odd Helge

    2011-01-07

    Ultrasonic imaging is becoming the most popular medical imaging modality, owing to the low price per examination and its safety. However, blood is a poor scatterer of ultrasound waves at clinical diagnostic transmit frequencies. For perfusion imaging, markers have been designed to enhance the contrast in B-mode imaging. These so-called ultrasound contrast agents consist of microscopically small gas bubbles encapsulated in biodegradable shells. In this review, the physical principles of ultrasound contrast agent microbubble behavior and their adjustment for drug delivery including sonoporation are described. Furthermore, an outline of clinical imaging applications of contrast-enhanced ultrasound is given. It is a challenging task to quantify and predict which bubble phenomenon occurs under which acoustic condition, and how these phenomena may be utilized in ultrasonic imaging. Aided by high-speed photography, our improved understanding of encapsulated microbubble behavior will lead to more sophisticated detection and delivery techniques. More sophisticated methods use quantitative approaches to measure the amount and the time course of bolus or reperfusion curves, and have shown great promise in revealing effective tumor responses to anti-angiogenic drugs in humans before tumor shrinkage occurs. These are beginning to be accepted into clinical practice. In the long term, targeted microbubbles for molecular imaging and eventually for directed anti-tumor therapy are expected to be tested.

  15. Perceptual Contrast Enhancement with Dynamic Range Adjustment

    Science.gov (United States)

    Zhang, Hong; Li, Yuecheng; Chen, Hao; Yuan, Ding; Sun, Mingui

    2013-01-01

    Recent years, although great efforts have been made to improve its performance, few Histogram equalization (HE) methods take human visual perception (HVP) into account explicitly. The human visual system (HVS) is more sensitive to edges than brightness. This paper proposes to take use of this nature intuitively and develops a perceptual contrast enhancement approach with dynamic range adjustment through histogram modification. The use of perceptual contrast connects the image enhancement problem with the HVS. To pre-condition the input image before the HE procedure is implemented, a perceptual contrast map (PCM) is constructed based on the modified Difference of Gaussian (DOG) algorithm. As a result, the contrast of the image is sharpened and high frequency noise is suppressed. A modified Clipped Histogram Equalization (CHE) is also developed which improves visual quality by automatically detecting the dynamic range of the image with improved perceptual contrast. Experimental results show that the new HE algorithm outperforms several state-of-the-art algorithms in improving perceptual contrast and enhancing details. In addition, the new algorithm is simple to implement, making it suitable for real-time applications. PMID:24339452

  16. Contrast-Enhanced Sonography for Diagnosing Collateral Transformation of the Hepatic Artery After Liver Transplantation.

    Science.gov (United States)

    Lyu, Su-Qin; Ren, Jie; Zheng, Rong-Qin; Meng, Xiao-Chun; Huang, Ming-Sheng; Wang, Ping

    2015-09-01

    To determine the contrast-enhanced sonographic features of hepatic artery collateral transformation in patients with hepatic artery complications after liver transplantation. Ninety-nine liver transplant recipients who underwent contrast-enhanced sonography were recruited from April 2004 to May 2014. The reference standards were conventional angiography and computed tomographic angiography. The contrast-enhanced sonographic features of the hepatic artery in patients with and without collateral arteries were retrospectively analyzed. All 15 patients with hepatic artery collateral transformation had hepatic artery thrombosis (10 of 15) or hepatic artery stenosis (5 of 15). The collateral artery detection rate on contrast-enhanced sonography was 100%. The peripheral hepatic artery could not be visualized by contrast-enhanced sonography in most of the patients with hepatic artery collateral transformation (14 of 15). Additionally, many small tortuous collateral arteries in the porta hepatis region were visualized during the arterial and early portal phases, showing reticulated/patchy (15 of 15) and striped (3 of 15) enhancement patterns on contrast-enhanced sonography. Collateral transformation of the hepatic artery in patients with hepatic artery complications after liver transplantation appears to have characteristic features on contrast-enhanced sonography, especially a reticulated or patchy enhancement pattern in the porta hepatis region during the arterial and early portal phases combined with the absence of the peripheral hepatic artery. Contrast-enhanced sonography may be a novel method for diagnosing hepatic artery collateral transformation, which may be a highly specific sign of hepatic artery thrombosis or stenosis. © 2015 by the American Institute of Ultrasound in Medicine.

  17. Dynamic Contrast-Enhanced MRI of Cervical Cancers: Temporal Percentile Screening of Contrast Enhancement Identifies Parameters for Prediction of Chemoradioresistance

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Erlend K.F. [Department of Medical Physics, Oslo University Hospital, Oslo (Norway); Hole, Knut Hakon; Lund, Kjersti V. [Department of Radiology, Oslo University Hospital, Oslo (Norway); Sundfor, Kolbein [Department of Gynaecological Oncology, Oslo University Hospital, Oslo (Norway); Kristensen, Gunnar B. [Department of Gynaecological Oncology, Oslo University Hospital, Oslo (Norway); Institute for Medical Informatics, Oslo University Hospital, Oslo (Norway); Lyng, Heidi [Department of Radiation Biology, Oslo University Hospital, Oslo (Norway); Malinen, Eirik, E-mail: eirik.malinen@fys.uio.no [Department of Medical Physics, Oslo University Hospital, Oslo (Norway); Department of Physics, University of Oslo, Oslo (Norway)

    2012-03-01

    Purpose: To systematically screen the tumor contrast enhancement of locally advanced cervical cancers to assess the prognostic value of two descriptive parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Methods and Materials: This study included a prospectively collected cohort of 81 patients who underwent DCE-MRI with gadopentetate dimeglumine before chemoradiotherapy. The following descriptive DCE-MRI parameters were extracted voxel by voxel and presented as histograms for each time point in the dynamic series: normalized relative signal increase (nRSI) and normalized area under the curve (nAUC). The first to 100th percentiles of the histograms were included in a log-rank survival test, resulting in p value and relative risk maps of all percentile-time intervals for each DCE-MRI parameter. The maps were used to evaluate the robustness of the individual percentile-time pairs and to construct prognostic parameters. Clinical endpoints were locoregional control and progression-free survival. The study was approved by the institutional ethics committee. Results: The p value maps of nRSI and nAUC showed a large continuous region of percentile-time pairs that were significantly associated with locoregional control (p < 0.05). These parameters had prognostic impact independent of tumor stage, volume, and lymph node status on multivariate analysis. Only a small percentile-time interval of nRSI was associated with progression-free survival. Conclusions: The percentile-time screening identified DCE-MRI parameters that predict long-term locoregional control after chemoradiotherapy of cervical cancer.

  18. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  19. Small (Renal Mass: Differentiation of Oncocytoma From Renal Cell Carcinoma on Biphasic Contrast-Enhanced CT.

    Science.gov (United States)

    Sasaguri, Kohei; Takahashi, Naoki; Gomez-Cardona, Daniel; Leng, Shuai; Schmit, Grant D; Carter, Rickey E; Leibovich, Bradley C; Kawashima, Akira

    2015-11-01

    The purpose of this study was to evaluate whether small (oncocytomas can be differentiated from renal cell carcinomas (RCCs) on biphasic contrast-enhanced CT. Forty-three patients with 53 oncocytomas and 123 patients with 128 RCCs (24 papillary subtype and 104 clear cell and other subtypes) who underwent biphasic contrast-enhanced CT were included in the study. Patient demographics and CT tumor characteristics were evaluated in each case. A multinomial logistic regression model was then constructed for differentiating oncocytoma from clear cell and other subtype RCCs, oncocytoma from papillary RCCs, and clear cell and other subtype RCCs from papillary RCCs. The probability of each group was calculated from the model. Diagnostic performance among three pairwise diagnoses and between oncocytoma and any RCC (clear cell and other subtypes and papillary) were assessed by AUC values. Patient age, tumor CT attenuation values and skewness (i.e., histogram analysis of CT values) in both the corticomedullary and nephrographic phases, and subjective tumor heterogeneity were statistically significant variables in the multinomial logistic regression analysis. The logistic regression model using the variables yielded AUCs of 0.82, 0.95, 0.91, and 0.84 for differentiating oncocytomas from clear cell and other subtype RCCs, oncocytomas from papillary RCCs, clear cell and other subtype RCCs from papillary RCCs, and oncocytomas from any RCC (clear cell and other subtypes and papillary), respectively. A combination of imaging features on biphasic CT, including tumor CT attenuation values and tumor texture (heterogeneity and skewness), can help differentiate oncocytoma from RCC.

  20. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography.

    Science.gov (United States)

    Tomita, Hayato; Yamada, Takayuki; Murakami, Kenji; Hashimoto, Kazuki; Tazawa, Yoko; Kumano, Reiko; Nakajima, Yasuo

    2015-05-01

    The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15-92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01±1.30 cm (range, 0.5-6.19) and 2.04±0.91 cm (0.5-4.4) in the left inferior thyroid vein and common trunk, and 1.96±1.05 cm (0.81-4.8) and 1.65±0.69 cm (0.63-2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This strategy can provide anatomical information before selective venous sampling for measurements of parathyroid hormone. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Evaluation of tumor angiogenesis of breast carcinoma using contrast-enhanced digital mammography.

    Science.gov (United States)

    Dromain, Clarisse; Balleyguier, Corrine; Muller, Serge; Mathieu, Marie-Christine; Rochard, France; Opolon, Paule; Sigal, Robert

    2006-11-01

    The purpose of this article is to assess the accuracy of contrast-enhanced digital mammography in the detection of breast carcinoma and to correlate the findings on the images with those of histologic analysis using microvessel quantification. Twenty patients with a suspicious breast abnormality underwent contrast-enhanced digital mammography using a full-field digital mammography unit that was modified to detect iodinated enhancement. For each patient, a total of six contrast-enhanced craniocaudal views were acquired from 30 seconds to 7 minutes after the injection of a bolus of 100 mL of an iodinated contrast agent. Image processing included a logarithmic subtraction and the analysis of enhancement kinetic curves. Contrast-enhanced digital mammography findings were compared with histologic analysis of surgical specimens, including intratumoral microvessel density quantification evaluated on CD34-immunostained histologic sections obtained from all patients. An area of enhancement was depicted on contrast-enhanced digital mammograms in 16 of the 20 histologically proven breast carcinomas. Excellent correlation was seen between the size of enhancement and the histologic size of tumors, which ranged from 9 to 22 mm. Early enhancement with washout was observed in four cases, early enhancement followed by a plateau in four cases, gradual enhancement in seven cases, and unexpected decrease of enhancement in one case. Intratumoral microvessel density ranged from 11.7 to 216.6 microvessels per square millimeter. A poor correlation was found between data measured on contrast-enhanced digital mammography and intratumoral microvessel density measured on CD34-immunostained histologic sections. Contrast-enhanced digital mammography is able to depict angiogenesis in breast carcinoma. Breast compression and projective images acquisition alter the quantitative assessment of enhancement parameters.

  2. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Hayato, E-mail: m04149@yahoo.co.jp [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Yamada, Takayuki; Murakami, Kenji; Hashimoto, Kazuki; Tazawa, Yoko; Kumano, Reiko [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Nakajima, Yasuo [Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa 216-8511 (Japan)

    2015-05-15

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  3. The clinical significance of persistent trigeminal nerve contrast enhancement in patients who undergo repeat radiosurgery.

    Science.gov (United States)

    Mousavi, Seyed H; Akpinar, Berkcan; Niranjan, Ajay; Agarwal, Vikas; Cohen, Jonathan; Flickinger, John C; Kondziolka, Douglas; Lunsford, L Dade

    2017-07-01

    OBJECTIVE Contrast enhancement of the retrogasserian trigeminal nerve on MRI scans frequently develops after radiosurgical ablation for the management of medically refractory trigeminal neuralgia (TN). The authors sought to evaluate the clinical significance of this imaging finding in patients who underwent a second radiosurgical procedure for recurrent TN. METHODS During a 22-year period, 360 patients underwent Gamma Knife stereotactic radiosurgery (SRS) as their first surgical procedure for TN at the authors' center. The authors retrospectively analyzed the data from 59 patients (mean age 72 years, range 33-89 years) who underwent repeat SRS for recurrent pain at a median of 30 months (range 6-146 months) after the first SRS. The isocenter was 4 mm, and the median maximum doses for the first and second procedures were 80 Gy and 70 Gy, respectively. A neuroradiologist and a neurosurgeon blinded to the treated side evaluated the presence of nerve contrast enhancement on MRI series at the time of the repeat procedure. The authors correlated the presence of this imaging change with clinical outcomes. Pain outcomes and development of trigeminal sensory dysfunction were evaluated with the Barrow Neurological Institute (BNI) Pain Scale and BNI Numbness Scale, respectively. The mean length of follow-up after the second SRS was 58 months (95% CI 49-68 months). RESULTS At the time of the repeat SRS, contrast enhancement of the trigeminal nerve on MRI scans was observed in 31 patients (53%). Five years after the SRS, patients with this enhancement had lower actuarial rates of complete pain relief after the repeat SRS (27% [95% CI 7%-47%]) than patients without the enhancement (76% [95% CI 58%-94%]) (p < 0.001). At the 5-year follow-up, patients with the contrast enhancement also had a higher risk for trigeminal sensory loss after repeat SRS (75% [95% CI 59%-91%]) than patients without contrast enhancement (26% [95% CI 10%-42%]) (p = 0.001). Dysesthetic pain after repeat SRS

  4. Contrast-Enhanced Computed Tomography in Intensive Care Unit Patients With Acute Clinical Deterioration: Impact of Hyperattenuating Adrenal Glands.

    Science.gov (United States)

    Boos, Johannes; Schek, Julia; Kröpil, Patric; Heusch, Philipp; Heinzler, Niklas; Antoch, Gerald; Lanzman, Rotem Shlomo

    2017-02-01

    The study sought to assess the frequency and prognostic value of hyperattenuating adrenal glands on contrast-enhanced computed tomography (CT) scans of surgical intensive care unit (ICU) patients with acute clinical deterioration. Eighty-eight consecutive ICU patients (63.2 ± 14.5 years of age) were included in this retrospective analysis. All patients underwent biphasic contrast-enhanced CT due to an acute clinical deterioration. Hyperattenuation of the adrenal glands was assessed subjectively and objectively. Subjective presence or absence of hyperattenuating adrenal glands was assessed by 2 blinded radiologists (J.B. and R.S.L.) in consensus. Hounsfield units (HU) were measured in the adrenal glands and in the inferior vena cava. Objective hyperattenuation was defined as HU (adrenal glands) > HU (inferior vena cava) with a 15-HU threshold. Death within 14 days following CT was set as endpoint and acquired from electronic patient data. Thirty-eight patients (43.2%, Group Asubj) exhibited hyperattenuation of the adrenal glands, whereas 50 patients (56.8%, Group Bsubj) did not. Concerning the objective analysis, 31 patients (35.2%, Group Aobj) exhibited hyperdense adrenal glands, whereas 53 patients (64.8%, Group Bobj) did not. Overall 27 of 88 patients (30.6%) died within 14 days following the CT examination. Lethal outcome was significantly more frequent among patients in Group Asubj and Aobj (19 of 38 patients [50.0%] and 15 of 31 patients [48.4%]) as compared with patients in Group Bsubj (8 of 50 patients [16.0%]) and Group Bobj (12 of 57 patients [21.1%]; P adrenal glands on contrast-enhanced CT of ICU patients with acute clinical deterioration is associated with a high mortality and might serve as a prognostic marker for patients' outcome. Copyright © 2016 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  5. Evaluation of dynamic contrast-enhanced T1-weighted perfusion MRI in the differentiation of tumor recurrence from radiation necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Vibeke A. [Glostrup University Hospital, Department of Radiology, Glostrup (Denmark); Glostrup University Hospital, Department of Radiology, Copenhagen Oe (Denmark); Simonsen, Helle J.; Larsson, Henrik B.W. [Glostrup University Hospital, Functional Imaging Unit, Glostrup (Denmark); Glostrup University Hospital, Department of Clinical Physiology, Glostrup (Denmark); Law, Ian [Nuclear Medicine and PET, Department of Clinical Physiology, Copenhagen Oe (Denmark); Hansen, Adam E. [Glostrup University Hospital, Department of Radiology, Glostrup (Denmark); Glostrup University Hospital, Functional Imaging Unit, Glostrup (Denmark)

    2013-03-15

    To investigate if perfusion measured with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can be used to differentiate radiation necrosis from tumor recurrence in patients with high-grade glioma. The study was approved by the institutional review board and informed consent was obtained from all subjects. 19 patients were recruited following surgery and radiation therapy for glioma. Patients had contrast enhancing lesions, which during the standard MRI examination could not be exclusively determined as recurrence or radiation necrosis. DCE-MRI was used to measure cerebral blood volume (CBV), blood-brain barrier (BBB) permeability and cerebral blood flow (CBF). Subjects also underwent FDG-PET and lesions were classified as either metabolically active or inactive. Follow-up clinical MRI and lesion histology in case of additional tissue resection was used to determine whether lesions were regressing or progressing. Fourteen enhancing lesions could be classified as progressing (11) or regressing (three). An empirical threshold of 2.0 ml/100 g for CBV allowed detection of regressing lesions with a sensitivity of 100 % and specificity of 100 %. FDG-PET and DCE-MRI agreed in classification of tumor status in 13 out of the 16 cases where an FDG-PET classification was obtained. In two of the remaining three patients, MRI follow-up and histology was available and both indicated that the DCE-MRI answer was correct. CBV measurements using DCE-MRI may predict the status of contrast enhancing lesions and give results very similar to FDG-PET with regards to differentiation between tumor recurrence and radiation necrosis. (orig.)

  6. Adaptive radiotherapy based on contrast enhanced cone beam CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Soevik, Aaste; Skogmo, Hege K. (Dept. of Companion Animal Clinical Sciences, Norwegian School of Veterinary Science, Oslo (Norway)), E-mail: aste.sovik@nvh.no; Roedal, Jan (Dept. of Companion Animal Clinical Sciences, Norwegian School of Veterinary Science, Oslo (Norway)); Lervaag, Christoffer; Eilertsen, Karsten; Malinen, Eirik (Dept. of Medical Physics, The Norwegian Radium Hospital, Oslo Univ. Hospital, Oslo (Norway))

    2010-10-15

    Cone beam CT (CBCT) imaging has become an integral part of radiation therapy, with images typically used for offline or online patient setup corrections based on bony anatomy co-registration. Ideally, the co-registration should be based on tumor localization. However, soft tissue contrast in CBCT images may be limited. In the present work, contrast enhanced CBCT (CECBCT) images were used for tumor visualization and treatment adaptation. Material and methods. A spontaneous canine maxillary tumor was subjected to repeated cone beam CT imaging during fractionated radiotherapy (10 fractions in total). At five of the treatment fractions, CECBCT images, employing an iodinated contrast agent, were acquired, as well as pre-contrast CBCT images. The tumor was clearly visible in post-contrast minus pre-contrast subtraction images, and these contrast images were used to delineate gross tumor volumes. IMRT dose plans were subsequently generated. Four different strategies were explored: 1) fully adapted planning based on each CECBCT image series, 2) planning based on images acquired at the first treatment fraction and patient repositioning following bony anatomy co-registration, 3) as for 2), but with patient repositioning based on co-registering contrast images, and 4) a strategy with no patient repositioning or treatment adaptation. The equivalent uniform dose (EUD) and tumor control probability (TCP) calculations to estimate treatment outcome for each strategy. Results. Similar translation vectors were found when bony anatomy and contrast enhancement co-registration were compared. Strategy 1 gave EUDs closest to the prescription dose and the highest TCP. Strategies 2 and 3 gave EUDs and TCPs close to that of strategy 1, with strategy 3 being slightly better than strategy 2. Even greater benefits from strategies 1 and 3 are expected with increasing tumor movement or deformation during treatment. The non-adaptive strategy 4 was clearly inferior to all three adaptive strategies

  7. Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Xu Huixiong, E-mail: xuhuixiong@hotmail.co [Department of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China); Chen Lida; Xie Xiaoyan; Xie Xiaohua; Xu Zuofeng; Liu Guangjian; Lin Manxia; Wang Zhu [Department of Medical Ultrasonics, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China); Lu Mingde, E-mail: lumd@21cn.co [Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, 58 Zhongshan Road 2, Guangzhou 510080 (China)

    2010-08-15

    Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% (16/19) for baseline ultrasound, 89.5% (17/19) for CEUS, and 78.9% (15/19) for CECT (all P > 0.05 between every two groups). CEUS significantly improved the lesion conspicuity in comparison with CECT. CEUS and CECT made correct diagnoses in 30 (93.8%) and 25 (78.1%) lesions prior to pathological examination (P = 0.125). Conclusion: The enhancement pattern of hilar cholangiocarcinoma on CEUS was similar with that on CECT in arterial phase, whereas in portal phase hilar cholangiocarcinoma shows hypoenhancement more likely on CEUS. CEUS and CECT lead to similar results in evaluating portal vein infiltration and diagnosis of this entity.

  8. Four-dimensional, multiphase, steady-state imaging with contrast enhancement (MUSIC) in the heart: a feasibility study in children.

    Science.gov (United States)

    Han, Fei; Rapacchi, Stanislas; Khan, Sarah; Ayad, Ihab; Salusky, Isidro; Gabriel, Simon; Plotnik, Adam; Finn, J Paul; Hu, Peng

    2015-10-01

    To develop a technique for high resolution, four-dimensional (4D), multiphase, steady-state imaging with contrast enhancement (MUSIC) in children with complex congenital heart disease. Eight pediatric patients underwent cardiovascular MRI with controlled mechanical ventilation after ferumoxytol administration. Breath-held contrast-enhanced MRA (CE-MRA) was performed during the first-pass and delayed phases of ferumoxytol, followed by a respiratory gated, 4D MUSIC acquisition during the steady state distribution phase of ferumoxytol. The subjective image quality and image sharpness were evaluated. Assessment of ventricular volumes based on 4D MUSIC was compared with those based on multislice 2D cardiac cine MRI. The 4D MUSIC technique provided cardiac-phase-resolved (65-95 ms temporal resolution) and higher spatial resolution (0.6-0.9 mm isotropic) images than previously achievable using first-pass CE-MRA or 2D cardiac cine. When compared with Ferumoxytol-based first-pass CE-MRA, the 4D MUSIC provided sharper images and better definition of the coronary arteries, aortic root, myocardium, and pulmonary trunk (P 0.95). The 4D MUSIC technique may represent a new paradigm in MR evaluation of cardiovascular anatomy and function in children with complex congenital heart disease. © 2014 Wiley Periodicals, Inc.

  9. Non-contrast-enhanced magnetic resonance angiography: techniques and applications.

    Science.gov (United States)

    Blankholm, Anne Dorte; Ringgaard, Steffen

    2012-01-01

    Non-contrast-enhanced magnetic resonance angiography has gained renewed interest since the discovery of the association between gadolinium-based contrast agents and nephrogenic systemic fibrosis. The following article is an overview of the different magnetic resonance angiography sequences, the technical possibilities and new developments. Clinical options and recent advancements will be highlighted, and recommendations for non-contrast-enhanced magnetic resonance angiography techniques in different anatomical regions will be given. Furthermore, the authors seek to predict the future of non-contrast-enhanced magnetic resonance angiography, with special focus on patients at risk.

  10. Use of contrast-enhanced ultrasonography in chronic pathologic canine testes

    OpenAIRE

    Volta, A.; Manfredi, S; Vignoli, M.; Russo, M.; England, G. C. W.; Rossi, F; Bigliardi, E.; Di Ianni, F.; Parmigiani, E; Bresciani, C.; Gnudi, G.

    2014-01-01

    Contrast-enhanced ultrasound with sulphur hexafluoride microbubbles was performed in seven healthy dogs without a history of reproductive pathology and with histologically confirmed normal testes and in 42 dogs with chronic scrotal anomalies. All dogs underwent orchiectomy and histological examination. Enhancement patterns and perfusion parameters (peak intensity and regional blood flow) of testes of healthy dogs and testes with chronic lesions were compared. Fourteen non-pathologic and 60 pa...

  11. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography

    Directory of Open Access Journals (Sweden)

    Rodrigo da Fonseca Monjardim

    2013-06-01

    Full Text Available Objective To evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and Methods In the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 × (0.75 × P + 0.25 × A] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results The simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity.

  12. Optimization of scantiming in abdominal breathhold contrast-enhanced MRA : an empirical guideline

    NARCIS (Netherlands)

    Boeve, WJ; Sluiter, WJ; Kamman, RL

    The objective of this study to determine a suitable scan timing scheme in contrast enhanced MRA for the depiction of the arterial. the portal and the systemic venous system in the abdomen with maximum signal intensity in healthy subjects and in patients with cirrhosis. The signal intensity in the

  13. Dual-energy contrast-enhanced spectral mammography (CESM).

    Science.gov (United States)

    Daniaux, Martin; De Zordo, Tobias; Santner, Wolfram; Amort, Birgit; Koppelstätter, Florian; Jaschke, Werner; Dromain, Clarisse; Oberaigner, Willi; Hubalek, Michael; Marth, Christian

    2015-10-01

    Dual-energy contrast-enhanced mammography is one of the latest developments in breast care. Imaging with contrast agents in breast cancer was already known from previous magnetic resonance imaging and computed tomography studies. However, high costs, limited availability-or high radiation dose-led to the development of contrast-enhanced spectral mammography (CESM). We reviewed the current literature, present our experience, discuss the advantages and drawbacks of CESM and look at the future of this innovative technique.

  14. Temporal subtraction contrast-enhanced dedicated breast CT

    Science.gov (United States)

    Gazi, Peymon M.; Aminololama-Shakeri, Shadi; Yang, Kai; Boone, John M.

    2016-09-01

    The development of a framework of deformable image registration and segmentation for the purpose of temporal subtraction contrast-enhanced breast CT is described. An iterative histogram-based two-means clustering method was used for the segmentation. Dedicated breast CT images were segmented into background (air), adipose, fibroglandular and skin components. Fibroglandular tissue was classified as either normal or contrast-enhanced then divided into tiers for the purpose of categorizing degrees of contrast enhancement. A variant of the Demons deformable registration algorithm, intensity difference adaptive Demons (IDAD), was developed to correct for the large deformation forces that stemmed from contrast enhancement. In this application, the accuracy of the proposed method was evaluated in both mathematically-simulated and physically-acquired phantom images. Clinical usage and accuracy of the temporal subtraction framework was demonstrated using contrast-enhanced breast CT datasets from five patients. Registration performance was quantified using normalized cross correlation (NCC), symmetric uncertainty coefficient, normalized mutual information (NMI), mean square error (MSE) and target registration error (TRE). The proposed method outperformed conventional affine and other Demons variations in contrast enhanced breast CT image registration. In simulation studies, IDAD exhibited improvement in MSE (0-16%), NCC (0-6%), NMI (0-13%) and TRE (0-34%) compared to the conventional Demons approaches, depending on the size and intensity of the enhancing lesion. As lesion size and contrast enhancement levels increased, so did the improvement. The drop in the correlation between the pre- and post-contrast images for the largest enhancement levels in phantom studies is less than 1.2% (150 Hounsfield units). Registration error, measured by TRE, shows only submillimeter mismatches between the concordant anatomical target points in all patient studies. The algorithm was

  15. Contrast-enhanced MR imaging of the endolymphatic sac in patients with sudden hearing loss

    Energy Technology Data Exchange (ETDEWEB)

    Naganawa, Shinji; Koshikawa, Tokiko; Fukatsu, Hiroshi; Ishigaki, Takeo [Department of Radiology, Nagoya University School of Medicine (Japan); Nakashima, Tsutomu [Department of Otolayngology, Nagoya University School of Medicine (Japan); Ichinose, Nobuyasu [Toshiba Nasu Operations, Tochigi (Japan)

    2002-05-01

    Our objective was to evaluate the frequency of contrast enhancement of the endolymphatic sac in patients with sudden hearing loss. Forty consecutive patients with sudden sensorineural hearing loss (20 males and 20 females; age range 11-82 years), 40 age-matched control subjects, and 5 patients with Meniere's disease were examined using the same imaging protocol on a 1.5-T MR system. Pre- and post-contrast-enhanced T1-weighted 3D spoiled gradient-echo sequence (3D SPGR; TR/TE=23/10 ms, no. of excitations=1, flip angle=30 ) images were obtained using a voxel size of 0.6 x 0.7 x 0.8 mm{sup 3}. Contrast enhancement in the area of the endolymphatic sac was assessed by two radiologists, and the frequency of contrast enhancement was compared between the three study groups. Enhancement of the ipsilateral endolymphatic sac was observed in 30 of the 40 patients with sudden hearing loss (75%). Twenty of these 30 patients also showed enhancement on the contralateral side, and 1 patient showed enhancement only on the contralateral side. Only 1 of the 5 patients with Meniere's disease showed enhancement. Nine of the 40 control subjects (22.5%) showed enhancement (bilateral enhancement in 5 subjects, unilateral in 4). The frequency of enhancement in patients with sudden hearing loss was significantly higher than that in control subjects (P<0.0001) or patients with Meniere's disease (P<0.05). The frequency of contrast enhancement of the endolymphatic sac is significantly increased in patients with sudden hearing loss, but further study is necessary to clarify the relationship between this finding and the pathophysiology of sudden hearing loss. (orig.)

  16. Dynamic contrast enhanced magnetic resonance imaging in chronic Achilles tendinosis.

    Science.gov (United States)

    Gärdin, Anna; Brismar, Torkel B; Movin, Tomas; Shalabi, Adel

    2013-11-22

    Chronic Achilles tendinosis is a common problem. When evaluating and comparing different therapies there is a need for reliable imaging methods. Our aim was to evaluate if chronic Achilles tendinosis affects the dynamic contrast-enhancement in the tendon and its surroundings and if short-term eccentric calf-muscle training normalizes the dynamic contrast-enhancement. 20 patients with chronic Achilles tendinopathy were included. Median duration of symptoms was 31 months (range 6 to 120 months). Both Achilles tendons were examined with dynamic contrast enhanced MRI before and after a 12- week exercise programme of eccentric calf-muscle training. The dynamic MRI was evaluated in tendon, vessel and in fat ventrally of tendon. Area under the curve (AUC), time to peak of signal, signal increase per second (SI/s) and increase in signal between start and peak as a percentage (SI%) was calculated. Pain and performance were evaluated using a questionnaire. In the fat ventrally of the tendon, dynamic contrast enhancement was significantly higher in the symptomatic leg compared to the contralateral non-symptomatic leg before but not after treatment. Despite decreased pain and improved performance there was no significant change of dynamic contrast enhancement in symptomatic tendons after treatment. In Achilles tendinosis there is an increased contrast enhancement in the fat ventrally of the tendon. The lack of correlation with symptoms and the lack of significant changes in tendon contrast enhancement parameters do however indicate that dynamic enhanced MRI is currently not a useful method to evaluate chronic Achilles tendinosis.

  17. Therapeutic response assessment of high intensity focused ultrasound therapy for uterine fibroid: Utility of contrast-enhanced ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Zhou Xiaodong [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China)]. E-mail: zhouxd@fmmu.edu.cn; Ren Xiaolong [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China)]. E-mail: renxiaolong70@hotmail.com; Zhang Jun [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); He Guangbin [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Zheng Minjuan [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Tian Xue [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Li Li [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Zhu Ting [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Zhang Min [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Wang Lei [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China); Luo Wen [Department of Ultrasonography, Xijing Hospital, Fourth Military Medical University, No. 17 West Changle Road, Xi' an 710032 (China)

    2007-05-15

    Purpose: To assess the utility of contrast-enhanced ultrasonography (ceUS) in the assessment of the therapeutic response to high intensity focused ultrasound (HIFU) ablation in patients with uterine fibroid. Materials and methods: Sixty-four patients with a total of 64 uterine fibroids (mean: 5.3 {+-} 1.2 cm; range: 3.2-8.9 cm) treated with HIFU ablation under the ultrasound guidance were evaluated with ceUS after receiving an intravenous bolus injection of a microbubble contrast agent (SonoVue) within 1 week after intervention. We obtained serial ceUS images during the time period from beginning to 5 min after the initiation of the bolus contrast injection. All of the patients underwent a contrast enhanced MRI (ceMRI) and ultrasound guided needle puncture biopsy within 1 week after HIFU ablation. And as a follow-up, all of the patients underwent US at 1, 3, 6 and 12 months after HIFU treatment. The volume change was observed and compared to pre- and post-HIFU ablation. The results of the ceUS were compared with those of the ceMRI in terms of the presence or absence of residual unablated tumor and pathologic change in the treated lesions. Results: On ceUS, diagnostic accuracy was 100%, while residual unablated tumors were found in three uterine fibroids (4.7%) and failed treatment was found in eight uterine fibroids (12.5%). All the 11 fibroids were subjected to additional HIFU ablation. Of the 58 ablated fibroids without residual tumors on both the ceUS and ceMRI after the HIFU ablation, the volumes of all the fibroids decreased in different degrees during the 1 year follow-up USs. And histologic examinations confirmed findings of necrotic and viable tumor tissue, respectively. Conclusion: CEUS is potentially useful for evaluating the early therapeutic effect of percutaneous HIFU ablation for uterine fibroids.

  18. Role of Contrast-Enhanced Ultrasound in the Follow-up of Kidney Transplant Patients.

    Science.gov (United States)

    Korda, D; Deák, P Á; Kozma, V; Kiss, G; Doros, A

    2016-09-01

    Contrast-enhanced ultrasound combines the advantages of native ultrasound and other contrast-enhanced imaging modalities. In selected cases it can be preferable to computerized tomographic scan among kidney transplant recipients. We performed a retrospective study involving patients of Semmelweis University Department of Transplantation and Surgery who underwent contrast-enhanced ultrasound examination from 2011 to 2015. During this period, 251 examinations were performed, including 45 on kidney transplant patients. A Toshiba Aplio XU ultrasound device was used, and 1-1.5 mL contrast agent (Sonovue) was administered intravenously for each patient. The indications of these evaluations can be divided into 3 groups: characterization of circumscribed kidney lesions, control after radiofrequency ablation therapy, and examination of graft perfusion. Fully 93% of the examinations were conclusive. In the 1st group of the 37 cases where tumor-suspect lesions were investigated, 13 examinations suggested the presence of a space-occupying lesion. Of those 13 cases, 2 patients had a negative biopsy, nephrectomy was performed in 11 cases, and histologic evaluation verified a tumor in 8 samples. In the 2nd group, the ablation control examination detected a residual tumor in none of the 6 cases. Finally, in 1 of the 2 grafts where the circulation was investigated, blood flow was satisfactory, and in the other it was low. The contrast-enhanced ultrasound examination was conclusive in most cases. The applied contrast material is not nephrotoxic, and the method uses nonionizing radiation. These features make contrast-enhanced ultrasound highly suitable for the examination of kidney transplant patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Contrast-enhanced CISS imaging of cerebellopontine angle tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Toyoda, Keiko; Hata, Yuichi; Fukuda, Yasushi; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine; Katano, Shuichi

    1999-10-01

    Our purpose of this study was to evaluate the clinical usefulness of contrast-enhanced CISS-3DFT MR imaging for the diagnosis of CP angle tumors. CISS-3DFT MR imaging is expected for screening procedure of acoustic schwannoma because of excellent spatial resolution. Recently, we discovered contrast enhancement effect on CISS sequence in spite of heavily T{sub 2}-weighted images. Fourteen patients with CP angle tumors were performed on a 1.0 T MR unit. Transaxial CISS-3DFT MRI was obtained both before and after intravenous injections of Gd-DTPA. Multiplanar reconstructions (MPRs) were performed in all cases. Contrast enhancement effect of CP angle tumors, and the relationship between tumors and the adjacent cranial nerves were evaluated. Contrast enhancement effect of the tumors was present in all cases in spite of heavily T{sub 2}-weighted images of CISS sequences. In the internal auditory canal, relationship between the tumors and the cranial nerves was demonstrated in 6 cases (6/9). In the cerebellopontine cistern, all cases were demonstrated (11/11). Contrast-enhanced CISS-3DFT MR imaging with a good contrast resolution and an excellent spatial resolution is useful for the diagnosis of CP angle tumors. (author)

  20. [Efficacy of gadobenate dimeglumine vs gadopentetate dimeglumine in contrast- enhanced magnetic resonance imaging for diagnosis of solitary brain metastases].

    Science.gov (United States)

    Wang, Qing-jun; Wang, Yong; Xu, Xian; Xiao, Hui; Ma, Lin

    2011-12-01

    To compare gadobenate dimeglumine (Gd-BOPTA) and gadopentetate dimeglumine (Gd-DTPA) for their efficacy as contrast agents in contrast-enhanced magnetic resonance imaging (MRI) for diagnosis of solitary brain metastases (SBM). We conducted an intra-individual study of contrast-enhanced T1-weighted MRI (T(1)WI) data from 27 Chinese patients with suspected SBM to compare the enhancement findings of two different MRI contrast agents, Gd-BOPTA and Gd-DTPA (at equivalent doses of 0.1 mmol/kg), for the detection of SBM. All the patients underwent two identical MRI examinations on a 3.0-T MRI scanner first with Gd-DTPA and then with Gd-BOPTA. Evaluation of the contrast enhancement was performed qualitatively (border delineation, extent, internal morphology, and contrast enhancement) and quantitatively (lesion-to-brain ratio, contrast-to-noise ratio, and percent enhancement) by 3 independent, fully blinded, and highly experienced neuroradiologists. Qualitative assessment by readers revealed a significant overall preference (P<0.05) for Gd-BOPTA over Gd-DOTA in terms of lesion border delineation, extent, lesion internal morphology, and contrast enhancement. Quantitative assessment also revealed a significant better performance of Gd-BOPTA in light of lesion-to-brain ratio (P<0.05), contrast-to-noise ratio (P<0.05), and percent enhancement (P<0.05). At an equivalent dose, Gd-BOPTA allows better contrast enhancement of SBM than Gd-DTPA in MRI.

  1. Contrast-enhanced magnetic resonance angiography for preoperative imaging in DIEP flap breast reconstruction.

    Science.gov (United States)

    Schaverien, Mark V; Ludman, Catherine N; Neil-Dwyer, Jason; Perks, Graeme B; Akhtar, Nadeem; Rodrigues, Jeremy N; Benetatos, Konstantinos; Raurell, Anna; Rasheed, Tuabin; McCulley, Stephen J

    2011-07-01

    Contrast-enhanced magnetic resonance angiography has been shown to be very accurate for identifying the perforator size, location, and intramuscular course, and the associated venous system, without exposing the patient to ionizing radiation. This study reports the authors' experience using this imaging modality in a large patient series. A retrospective review of patients who had undergone preoperative contrast-enhanced magnetic resonance angiography followed by free abdominal flap breast reconstruction was conducted. The results of imaging were compared with intraoperative findings, and surgical outcomes were compared with scan data. The results were compared with control data in patients who did not undergo presurgical imaging. One hundred thirty-two patients underwent contrast-enhanced magnetic resonance angiography presurgical imaging, and the results were compared with 84 controls. The imaging was found to be accurate for evaluating the perforator anatomy for free abdominal flap planning, with a high concordance between imaging and intraoperative findings. Without presurgical angiography, the ratio of deep inferior epigastric perforator (DIEP) flap-to-free transverse rectus abdominis musculocutaneous flap harvest was 0.9:1; with presurgical imaging, the ratio was 1.6:1 (p angiography, there was a mean reduction in operating time of 26 minutes for unilateral DIEP flap harvest and 40 minutes for bilateral harvest, although these values were not significant. There was a significant reduction in the partial flap failure rate with preoperative imaging. Presurgical imaging using contrast-enhanced magnetic resonance angiography demonstrates a high concordance with intraoperative findings. In this series, the percentage of flaps that were raised as DIEP flaps was significantly increased in patients who underwent preoperative imaging, and the partial flap failure rate was significantly reduced. : Therapeutic, III.(Figure is included in full-text article.).

  2. Dynamic contrast-enhanced MRI assessment of hyperemic fractional microvascular blood plasma volume in peripheral arterial disease: initial findings.

    Directory of Open Access Journals (Sweden)

    Bas Versluis

    Full Text Available OBJECTIVES: The aim of the current study was to describe a method that assesses the hyperemic microvascular blood plasma volume of the calf musculature. The reversibly albumin binding contrast agent gadofosveset was used in dynamic contrast-enhanced magnetic resonance imaging (DCE MRI to assess the microvascular status in patients with peripheral arterial disease (PAD and healthy controls. In addition, the reproducibility of this method in healthy controls was determined. MATERIALS AND METHODS: Ten PAD patients with intermittent claudication and 10 healthy control subjects were included. Patients underwent contrast-enhanced MR angiography of the peripheral arteries, followed by one DCE MRI examination of the musculature of the calf. Healthy control subjects were examined twice on different days to determine normative values and the interreader and interscan reproducibility of the technique. The MRI protocol comprised dynamic imaging of contrast agent wash-in under reactive hyperemia conditions of the calf musculature. Using pharmacokinetic modeling the hyperemic fractional microvascular blood plasma volume (V(p, unit: % of the anterior tibial, gastrocnemius and soleus muscles was calculated. RESULTS: V(p was significantly lower for all muscle groups in PAD patients (4.3±1.6%, 5.0±3.3% and 6.1±3.6% for anterior tibial, gastrocnemius and soleus muscles, respectively compared to healthy control subjects (9.1±2.0%, 8.9±1.9% and 9.3±2.1%. Differences in V(p between muscle groups were not significant. The coefficient of variation of V(p varied from 10-14% and 11-16% at interscan and interreader level, respectively. CONCLUSIONS: Using DCE MRI after contrast-enhanced MR angiography with gadofosveset enables reproducible assessment of hyperemic fractional microvascular blood plasma volume of the calf musculature. V(p was lower in PAD patients than in healthy controls, which reflects a promising functional (hemodynamic biomarker for the

  3. Small-bowel MRI in children and young adults with Crohn disease: retrospective head-to-head comparison of contrast-enhanced and diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, Henning; Evangelista, Laura; Wirth, Clemens; Beer, Meinrad [University Hospital Wuerzburg, Institute of Radiology, Department of Paediatric Radiology, Wuerzburg (Germany); Pabst, Thomas; Machann, Wolfram; Koestler, Herbert; Hahn, Dietbert [University Hospital Wuerzburg, Institute of Radiology, Wuerzburg (Germany); Dick, Anke [University Hospital Wuerzburg, Department of Paediatrics, Wuerzburg (Germany)

    2013-01-15

    Small-bowel MRI based on contrast-enhanced T1-weighted sequences has been challenged by diffusion-weighted imaging (DWI) for detection of inflammatory bowel lesions and complications in patients with Crohn disease. To evaluate free-breathing DWI, as compared to contrast-enhanced MRI, in children, adolescents and young adults with Crohn disease. This retrospective study included 33 children and young adults with Crohn disease ages 17 {+-} 3 years (mean {+-} standard deviation) and 27 matched controls who underwent small-bowel MRI with contrast-enhanced T1-weighted sequences and DWI at 1.5 T. The detectability of Crohn manifestations was determined. Concurrent colonoscopy as reference was available in two-thirds of the children with Crohn disease. DWI and contrast-enhanced MRI correctly identified 32 and 31 patients, respectively. All 22 small-bowel lesions and all Crohn complications were detected. False-positive findings (two on DWI, one on contrast-enhanced MRI), compared to colonoscopy, were a result of large-bowel lumen collapse. Inflammatory wall thickening was comparable on DWI and contrast-enhanced MRI. DWI was superior to contrast-enhanced MRI for detection of lesions in 27% of the assessed bowel segments and equal to contrast-enhanced MRI in 71% of segments. DWI facilitates fast, accurate and comprehensive workup in Crohn disease without the need for intravenous administration of contrast medium. Contrast-enhanced MRI is superior in terms of spatial resolution and multiplanar acquisition. (orig.)

  4. Assessment of the link between quantitative biexponential diffusion-weighted imaging and contrast-enhanced MRI in the liver

    NARCIS (Netherlands)

    Dijkstra, Hildebrand; Oudkerk, Matthijs; Kappert, Peter; Sijens, Paul E.

    Purpose: To investigate if intravoxel incoherent motion (IVIM) modeled diffusion-weighted imaging (DWI) can be linked to contrast-enhanced (CE-)MRI in liver parenchyma and liver lesions. Methods: Twenty-five patients underwent IVIM-DWI followed by multiphase CE-MRI using Gd-EOB-DTPA (n = 20) or

  5. Microbubble contrast-enhanced ultrasound in liver transplantation.

    Science.gov (United States)

    Berry, Jonathan D; Sidhu, Paul S

    2004-10-01

    The use of liver transplantation for treatment of end-stage liver disease is now commonplace. The accurate assessment of the pre-transplant candidate and long-term follow-up of the posttransplant patient is vital in ensuring that the limited resource of donor livers is appropriately used. Ultrasound is accepted as playing an important role in this process. The advent of microbubble contrast enhanced ultrasound provides new opportunities in terms of improving diagnostic accuracy and obviating more invasive investigations with their associated patient morbidity and mortality. We present the current and developing applications of microbubble contrast-enhanced ultrasound in the field of liver transplantation.

  6. Contrast-enhanced cardiovascular magnetic resonance in primary and ischemic dilated cardiomyopathy.

    Science.gov (United States)

    Calore, Chiara; Cacciavillani, Luisa; Boffa, Giovanni Maria; Silva, Caterina; Tiso, Enrico; Marra, Martina Perazzolo; Bacchiega, Enrico; Corbetti, Francesco; Iliceto, Sabino

    2007-10-01

    Differentiation between primary dilated cardiomyopathy and ischemic cardiomyopathy has an important clinical significance. Contrast-enhanced cardiovascular magnetic resonance can play a role in this task, identifying myocardial scarring or fibrosis as presence of delayed enhancement. The aim of the present study was to evaluate the diagnostic potential of contrast-enhanced cardiovascular magnetic resonance in differentiating dilated cardiomyopathy from ischemic cardiomyopathy. Contrast-enhanced cardiovascular magnetic resonance was performed in 100 patients with left ventricular dilatation and reduced systolic function: 24 had normal coronary arteries (dilated cardiomyopathy group) and 76 had significant coronary artery disease (ischemic cardiomyopathy group), with or without previous myocardial infarction. In the dilated cardiomyopathy group, only seven (29%) patients showed delayed enhancement and its pattern was characterized by mid-wall, patchy or diffuse location. All patients with ischemic cardiomyopathy and prior myocardial infarction (54 subjects) showed delayed enhancement with subendocardial (n = 4) or transmural (n = 50) extension. Among the 22 patients with ischemic cardiomyopathy but without previous myocardial infarction, 13 (59%) showed either subendocardial (n = 4) or transmural (n = 9) delayed enhancement. Patterns of delayed enhancement are different in dilated cardiomyopathy and ischemic cardiomyopathy, reflecting the presence of scarring or various degrees of fibrosis in left ventricular myocardium. The presence of subendocardial or transmural delayed enhancement at contrast-enhanced cardiovascular magnetic resonance allowed distinction between dilated cardiomyopathy and ischemic cardiomyopathy with high sensitivity (88%) and specificity (100%). Integration of cardiovascular magnetic resonance results with angiographic information can be useful in the identification of pathogenic mechanisms underlying left ventricular dysfunction.

  7. Differences in perfusion parameters between upper and lower lumbar vertebral segments with dynamic contrast-enhanced MRI (DCE MRI)

    Energy Technology Data Exchange (ETDEWEB)

    Savvopoulou, Vasiliki; Vlahos, Lampros; Moulopoulos, Lia Angela [University of Athens, Areteion Hospital, Department of Radiology, Medical School, Athens (Greece); Maris, Thomas G. [University of Crete, Deparment of Medical Physics, Faculty of Medicine, Heraklion (Greece)

    2008-09-15

    To investigate the influence of age, sex and spinal level on perfusion parameters of normal lumbar bone marrow with dynamic contrast-enhanced MRI (DCE MRI). Sixty-seven subjects referred for evaluation of low back pain or sciatica underwent DCE MRI of the lumbar spine. After subtraction of dynamic images, a region of interest (ROI) was placed on each lumbar vertebral body of all subjects, and time intensity curves were generated. Consequently, perfusion parameters were calculated. Statistical analysis was performed to search for perfusion differences among lumbar vertebrae and in relation to age and sex. Upper (L1, L2) and lower (L3, L4, L5) vertebrae showed significant differences in perfusion parameters (p<0.05). Vertebrae of subjects younger than 50 years showed significantly higher perfusion compared to vertebrae of older ones (p<0.05). Vertebrae of females demonstrated significantly increased perfusion compared to those of males of corresponding age (p<0.05). All perfusion parameters, except for washout (WOUT), showed a mild linear correlation with age. Time to maximum slope (TMSP) and time to peak (TTPK) showed the same correlation with sex (0.22subjects and of females compared to males. (orig.)

  8. Adrenal glands in hypovolemic shock: preservation of contrast enhancement at dynamic computed tomography.

    Science.gov (United States)

    Ito, Katsuyoshi; Higashi, Hiroki; Kanki, Akihiko; Tamada, Tsutomu; Yamashita, Takenori; Yamamoto, Akira; Watanabe, Shigeru

    2010-07-01

    To evaluate contrast enhancement effects of the adrenal glands at dynamic computed tomography (CT) in adult severe trauma patients with hypovolemic shock in comparison with patients without hypovolemic shock. This study population included a total of 74 patients with (n = 24) and without (n = 50) blunt trauma and hypovolemic shock. Measurement of CT attenuation values of the adrenal gland and calculation of the enhancement washout percentages were performed. The mean +/- SD CT attenuation values of the adrenal glands in the arterial phase of dynamic CT in patients with hypovolemic shock (137.3 +/- 41.7 Hounsfield unit [HU]) were not significantly different (P = 0.16) from those in control subjects (127.3 +/- 19.6 HU). The mean CT attenuation values of the adrenal glands in the delayed phase of dynamic CT in patients with hypovolemic shock (82.0 +/- 14.7 HU) were also not significantly different (P = 0.89) from those in control subjects (82.4 +/- 10.0 HU). The mean percentage (35%) of enhancement washout of the adrenal glands in patients with hypovolemic shock was not significantly different (P = 0.81) from that (34%) in control subjects. Contrast enhancement effects of the adrenal glands at contrast-enhanced dynamic CT in patients with hypovolemic shock were similar to those in control subjects, indicating the preserved enhancement and perfusion of the adrenal gland rather than intense and persistent enhancement in patients with hypovolemic shock.

  9. Contrast-enhanced ultrasound: clinical applications in patients with atherosclerosis

    NARCIS (Netherlands)

    A.F.L. Schinkel (Arend); M. Kaspar (Mathias); D. Staub (Daniel)

    2016-01-01

    textabstractContrast-enhanced ultrasound (CEUS) is increasingly being used to evaluate patients with known or suspected atherosclerosis. The administration of a microbubble contrast agent in conjunction with ultrasound results in an improved image quality and provides information that cannot be

  10. Sentinel node detection in melanomas using contrast-enhanced ultrasound

    DEFF Research Database (Denmark)

    Nielsen, K. Rue; Klyver, H.; Chakera, A. Hougaard

    2009-01-01

    BACKGROUND: Sentinel node (SN) biopsy has proven to be a useful clinical method based on the combination of radionuclide tracer principles and the dye technique. Contrast-enhanced ultrasound (CEUS) has been used successfully for detection of SN in animals, but the use of CEUS has not been reported...

  11. Staging accuracy of pancreatic cancer: Comparison between non-contrast-enhanced and contrast-enhanced PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, Tomohiro [Department of Radiology, Yokohama City University, Graduate School of Medicine, Yokohama (Japan); Tateishi, Ukihide, E-mail: utateish@yokohama-cu.ac.jp [Department of Radiology, Yokohama City University, Graduate School of Medicine, Yokohama (Japan); Endo, Itaru [Department of Surgery, Yokohama City University, Graduate School of Medicine, Yokohama (Japan); Inoue, Tomio [Department of Radiology, Yokohama City University, Graduate School of Medicine, Yokohama (Japan)

    2014-10-15

    Purpose: Our aim was to clarify the diagnostic impact of contrast-enhanced (CE) {sup 18}F-fluorodeoxyglucose (FDG)–positron emission tomography (PET)/computed tomography (CT) for staging of pancreatic cancer compared to non-CE PET/CT. Method and materials: Between April 2006 and November 2009, a total of 95 patients (age range, 36–83 years [mean age, 67]) with primary pancreatic cancer underwent {sup 18}F-FDG PET/CT examinations. Diagnostic accuracy was compared between non-CE PET/CT and CE PET/CT. Images were analyzed visually and quantitatively by two blinded reviewers. Reference standard was histological examination in 48 patients (51%) and/or confirmation of an obvious progression in number and/or size of the lesions on follow-up CT examinations in 47 patients (49%). Results: For T-staging, invasion of duodenum (n = 20, 21%), mesentery (n = 12, 13%), and retroperitoneum (n = 13, 14%) was correctly diagnosed by both modalities. The ROC analyses revealed that the Az values of celiac artery (CA), common hepatic artery (CHA), splenic artery (SV), and superior mesenteric vein (SMV) invasion were significantly higher in the CE PET/CT group for both readers. Nodal metastasis was correctly diagnosed by CE PET/CT in 38 patients (88%) and by non-CE PET/CT in 45 patients (87%). Diagnostic accuracies of nodal metastasis in two modalities were similar. Using CE PET/CT, distant metastasis, scalene node metastasis, and peritoneal dissemination were correctly assigned in 39 patients (91%), while interpretation based on non-CE PET/CT revealed distant metastasis, scalene node metastasis, and peritoneal dissemination in 42 patients (81%). Diagnostic accuracy of distant metastasis, scalene node metastasis, and peritoneal dissemination with CE PET/CT was significantly higher than that of non-CE PET/CT (p < 0.05). Conclusion: CE PET/CT allows a more precise assessment of distant metastasis, scalene node metastasis, and peritoneal dissemination in patients with pancreatic cancer.

  12. Feasibility of Left Ventricular Global Longitudinal Strain Measurements from Contrast-Enhanced Echocardiographic Images.

    Science.gov (United States)

    Medvedofsky, Diego; Lang, Roberto M; Kruse, Eric; Guile, Brittney; Weinert, Lynn; Ciszek, Boguslawa; Jacobson, Zachary; Negron, Jacqueline; Volpato, Valentina; Prado, Aldo; Patel, Amit R; Mor-Avi, Victor

    2017-11-23

    Although left ventricular global longitudinal strain (GLS) is an index of systolic function recommended by the guidelines, poor image quality may hamper strain measurements. While contrast agents are commonly used to improve endocardial visualization, no commercial speckle-tracking software is able to measure strain in contrast-enhanced images. This study aimed to test the accuracy of speckle-tracking software when applied to contrast-enhanced images in patients with suboptimal image quality. We studied patients with a wide range of GLS values who underwent transthoracic echocardiography. Protocol 1 included 44 patients whose images justified use of contrast but still allowed noncontrast speckle-tracking echocardiography (STE), which was judged as accurate and used as a reference. Protocol 2 included 20 patients with poor image quality that precluded noncontrast STE; cardiac magnetic resonance- (CMR-) derived strain was used as the reference instead. Half the manufacturer recommended dose of a commercial contrast agent (Definity/Optison/Lumason) was used to provide partial contrast enhancement. Higher than normal mechanical indices (0.6-0.7) and lowest frequency range for maximal penetration settings were used for imaging. GLS was measured (Epsilon) with and without contrast-enhanced images and by CMR-derived feature tracking (TomTec). Comparisons included linear regression and Bland-Altman analyses. The contrast STE analysis failed in 4/64 patients (6%). Manual corrections were needed to optimize tracking with contrast in all patients. GLS measurements were in good agreement between contrast and noncontrast images (r = 0.85; mean GLS in the contrast images, -12.9% ± 4.7%; bias, 0.34% ± 2.4%). Good agreement was also noted between contrast STE- and CMR-derived strain (r = 0.83; mean, GLS -13.5% ± 4.0%; bias, 0.72% ± 2.5%). We found that GLS measurements from contrast-enhanced images are feasible and accurate in most patients, even in those with poor

  13. Contrast-enhanced ultrasound in ovarian tumors – diagnostic parameters: method presentation and initial experience

    Science.gov (United States)

    MAXIM, ANITA-ROXANA; BADEA, RADU; TAMAS, ATILLA; TRAILA, ALEXANDRU

    2013-01-01

    The aim of this paper is to discuss and illustrate the use of contrast-enhanced ultrasound in evaluating ovarian tumors compared to conventional ultrasound, Doppler ultrasound and the histopathological analysis and suggest how this technique may best be used to distinguish benign from malignant ovarian masses. We present the method and initial experience of our center by analyzing the parameters used in contrast-enhanced ultrasound in 6 patients with ovarian tumors of uncertain etiology. For examination we used a Siemens ultrasound machine with dedicated contrast software and the contrast agent SonoVue, Bracco. The patients underwent conventional ultrasound, Doppler ultrasound and i.v. administration of the contrast agent. The parameters studied were: inflow of contrast (rise time), time to peak enhancement, mean transit time. The series of patients is part of an extensive prospective PhD study aimed at elaborating a differential diagnosis protocol for benign versus malignant ovarian tumors, by validating specific parameters for contrast-enhanced ultrasound. Although the method is currently used with great success in gastroenterology, urology and senology, its validation in gynecology is still in the early phases. Taking into consideration that the method is minimally invasive and much less costly that CT/MRI imaging, demonstrating its utility in oncologic gynecology would be a big step in preoperative evaluation of these cases. PMID:26527912

  14. Breast contrast-enhanced MR imaging: semiautomatic detection of vascular map.

    Science.gov (United States)

    Fusco, Roberta; Sansone, Mario; Filice, Salvatore; Petrillo, Antonella

    2016-03-01

    The diagnostic value of breast vascular maps using contrast-enhanced MR imaging has recently been explored. We propose a semiautomatic method to obtain breast vascular maps and to measure the number of blood vessels in the breast. From January 2011 to December 2013, 188 patients underwent breast contrast-enhanced MRI; patients with unilateral and histopathologically confirmed breast lesions were included in this study; 123 patients had malignant lesions and 65 patients had benign tissue diagnoses. Breast semiautomatic vascular map detection was performed using Hessian matrix-based method and morphologic operators. Blood vessels detection was compared with radiologic interpretation findings to evaluate algorithm goodness. Increase in vascularity associated with ipsilateral cancer was also assessed. Chi square test was used to observe statistically significant difference. A total of 1315 blood vessels were identified using semiautomatic procedure; 1034 were correctly classified (78.7 %), 261 (19.8 %) were incorrectly classified, and 20 (1.5 %) were missing. A significant association was found between one-sided increased breast vascularity and ipsilateral malignancy (p breast cancer could be performed with semiautomatic vascular mapping of contrast-enhanced MR imaging.

  15. Glioblastoma Presenting with Steroid-Induced Pseudoregression of Contrast Enhancement on Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Marcus D. Mazur

    2012-01-01

    Full Text Available Corticosteroid-induced reduction in contrast enhancement on radiographic imaging is most commonly associated with lymphoma but has been reported in other entities, including glioma. This finding may represent a diagnostic dilemma. Concern that steroid-induced cytotoxicity obscures histological diagnosis of suspected lymphoma may lead to postponement of a biopsy. If glioma is not considered in the differential diagnosis, reduction in tumor contrast enhancement may be misinterpreted as disease regression rather than a transient radiographic change. We report a case of a patient with an enhancing right temporoparietal mass adjacent to the atrium of the lateral ventricle. After treatment with dexamethasone was started, the mass exhibited marked reduction in contrast enhancement, with symptom improvement. The clinical course suggested lymphoma, and surgery was not performed. Subsequent screening for extra-axial lymphoma was negative. Two weeks later, the patient developed worsening symptoms, and repeat T1-weighted imaging showed interval increase in size and enhancement. The findings suggested a possible diagnosis of malignant glioma. The patient underwent a stereotactic-guided craniotomy for excision of the right temporoparietal mass lesion. Final histological diagnosis was glioblastoma multiforme, World Health Organization grade IV.

  16. Diagnostic Value of Contrast-Enhanced Ultrasound Evaluation of Malignant and Benign Solitary Thyroid Nodules

    Directory of Open Access Journals (Sweden)

    Priedītis Pēteris

    2016-02-01

    Full Text Available The aim of the study was to investigate the diagnostic value of contrast-enhanced ultrasound (CEUS in differentiating benign and malignant thyroid nodules. Thirty-five patients with morphologically proved thyroid nodules (17 malignant; 18 benign, underwent CEUS examination. Five enhancement patterns were evaluated: vascularisation, homogeneity, presence of peripheral rim type enhancement, wash-out rate of the contrast medium, and enhancement using microvascular imaging application. Time-intensity curves (TIC were analysed in post-processing and defined as three types: slow versus rapid and stable versus rapid biphasic wash-out. Diagnostic value of the listed CEUS parameters was calculated. The results showed medium strength correlation between morphology (benign versus malignant nodule and type of TIC curve rs = 0.38 (p = 0.021, as well as between mode of contrast enhancement rs = 0.39 (p = 0.022 and wash-out pattern rs =0.39 (p = 0.024. The overall pooled sensitivity of selected diagnostic parameters was 82%, specificity 57%, and accuracy 70%. Malignant nodules were characterised by iso- or hypovascular contrast enhancement and slow wash-out, while benign nodules showed hypervascular enhancement with rapid wash-out TIC curve and rim-like pattern. The CEUS patterns significantly differed between malignant and benign thyroid nodules with high diagnostic accuracy. Thus, CEUS has important clinical value as an additional tool to ultrasound and fine needle biopsy.

  17. Medical Image Visual Appearance Improvement Using Bihistogram Bezier Curve Contrast Enhancement: Data from the Osteoarthritis Initiative

    National Research Council Canada - National Science Library

    Gan, Hong-Seng; Swee, Tan Tian; Abdul Karim, Ahmad Helmy; Sayuti, Khairil Amir; Abdul Kadir, Mohammed Rafiq; Tham, Weng-Kit; Wong, Liang-Xuan; Chaudhary, Kashif T; Ali, Jalil; Yupapin, Preecha P

    2014-01-01

    .... In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of "adequate contrast enhancement" to overcome sudden jump problem in knee magnetic resonance image...

  18. Comparison of contrast-enhanced ultrasound and contrast-enhanced computed tomography in evaluating the treatment response to transcatheter arterial chemoembolization of hepatocellular carcinoma using modified RECIST

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ming; Lin, Man-xia; Xu, Zuo-feng; Wang, Wei; Xie, Xiao-yan [Sun Yat-Sen University, Department of Medical Ultrasonics, Guangzhou (China); Sun Yat-Sen University, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Guangzhou (China); Lu, Ming-de; Kuang, Ming [Sun Yat-Sen University, Department of Hepatobiliary Surgery, Guangzhou (China); Sun Yat-Sen University, The First Affiliated Hospital, Institute of Diagnostic and Interventional Ultrasound, Guangzhou (China); Zheng, Ke-guo [Sun Yat-Sen University, Department of Radiology, Guangzhou (China); Zhuang, Wen-quan [Sun Yat-Sen University, Department of Interventional Radiology, Guangzhou (China)

    2015-08-15

    We aimed to compare contrast-enhanced ultrasound (CEUS) with contrast-enhanced computed tomography (CECT) for evaluating the treatment response to transcatheter arterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). Treatment responses of 130 patients who underwent TACE were evaluated by CEUS and CECT. We initially compared the abilities of CEUS and CECT to detect residual tumour, which were confirmed by histology or angiography. Then, we compared the tumour response to TACE assessed by CEUS and CECT, according to Modified Response Evaluation Criteria in Solid Tumours (mRECIST). The sensitivity and accuracy of detecting residual tumour by CEUS vs. CECT were 95.9 % vs. 76.2 % (p < 0.001) and 96.2 % vs. 77.7 % (p < 0.001), respectively. For target lesions, 13 patients were observed as complete response (CR) by CEUS, compared to 36 by CECT (p < 0.001). For nontarget lesions, 12 patients were observed as CR by CEUS, compared to 22 by CECT (p = 0.006). For overall response, eight patients were observed as CR by CEUS, compared to 31 by CECT (p < 0.001). The diagnostic performance of CEUS was superior to CECT for detecting residual tumour after TACE. In clinical, CEUS should be recommended as an optional procedure for assessing the tumour response to TACE. (orig.)

  19. Diagnostic accuracy of magnetic resonance, computed tomography and contrast enhanced ultrasound in radiological multimodality assessment of peribiliary liver metastases.

    Directory of Open Access Journals (Sweden)

    Vincenza Granata

    Full Text Available We compared diagnostic performance of Magnetic Resonance (MR, Computed Tomography (CT and Ultrasound (US with (CEUS and without contrast medium to identify peribiliary metastasis.We identified 35 subjects with histological proven peribiliary metastases who underwent CEUS, CT and MR study. Four radiologists evaluated the presence of peribiliary lesions, using a 4-point confidence scale. Echogenicity, density and T1-Weigthed (T1-W, T2-W and Diffusion Weighted Imaging (DWI signal intensity as well as the enhancement pattern during contrast studies on CEUS, CT and MR so as hepatobiliary-phase on MRI was assessed.All lesions were detected by MR. CT detected 8 lesions, while US/CEUS detected one lesion. According to the site of the lesion, respect to the bile duct and hepatic parenchyma: 19 (54.3% were periductal, 15 (42.8% were intra-periductal and 1 (2.8% was periductal-intrahepatic. According to the confidence scale MRI had the best diagnostic performance to assess the lesion. CT obtained lower diagnostic performance. There was no significant difference in MR signal intensity and contrast enhancement among all metastases (p>0.05. There was no significant difference in CT density and contrast enhancement among all metastases (p>0.05.MRI is the method of choice for biliary tract tumors but it does not allow a correct differential diagnosis among different histological types of metastasis. The presence of biliary tree dilatation without hepatic lesions on CT and US/CEUS study may be an indirect sign of peribiliary metastases and for this reason the patient should be evaluated by MRI.

  20. Evaluation of the microcirculatory disturbance of biliary ischemia after liver transplantation with contrast-enhanced ultrasound: preliminary experience.

    Science.gov (United States)

    Ren, Jie; Lu, Ming-De; Zheng, Rong-Qin; Lu, Min-Qiang; Liao, Mei; Mao, Yong-Jiang; Zheng, Zhi-Juan; Lu, Yan

    2009-12-01

    The aim of this study was to determine the efficacy of contrast-enhanced ultrasound for depicting the perfusion of hilar bile ducts in ischemic-type biliary lesions after orthotopic liver transplantation. Thirteen transplant recipients with ischemic-type biliary lesions and 12 patients without ischemic-type biliary lesions underwent ultrasound examinations after the injection of 1.5 mL of an intravenous contrast agent. The enhancement of the hilar bile duct wall in the arterial, portal venous, and late phases was qualitatively graded as higher, equal, lower, or none with respect to that of the adjacent liver parenchyma. No or low contrast enhancement was seen in 10 of 13 patients (76.90%) with biliary ischemia, whereas increased contrast enhancement with respect to the normal liver parenchyma was found in all 12 patients without biliary ischemia. The difference in the enhancement patterns between the 2 groups was significant (P = 0.0001). In conclusion, contrast-enhanced ultrasound is a new imaging modality to depict perfusion of the hilar bile duct. No or low contrast enhancement of the bile duct wall in the arterial phase may reflect the microcirculatory disturbance of biliary ischemia and may contribute to its early diagnosis.

  1. [Value of quantitative examination via contrast-enhanced ultrasonography in evaluating the activity of Crohn disease at endoscopy].

    Science.gov (United States)

    Chen, Cheng-long; Wang, Wang-yue; Chen, Guang-lan; Zhang, Chun-lai

    2011-11-01

    To evaluate the predictive value of quantitative examination via contrast-enhanced ultrasonography on the activity of Crohn disease at endoscopy. A total of 59 cases with Crohn disease in People's Hospital of Lishui City between January 2009 and December 2010 were collected prospectively and underwent both colonoscopy and contrast-enhanced ultrasonography. According to the Simple Endoscopic Score, Crohn disease was divided into inactive and active disease by colonoscopy. To assess the vascularization of the involved bowel loop in a region expected to be seen at colonoscopy, the contrast agent uptake was measured by using quantitative analysis. Measurement of contrast enhancement was assessed as the percentage of increase in wall brightness in regions of interest (ROI). The receiver operating characteristic curve was used to evaluate the value of contrast agent uptake in predicting the severity determined at endoscopy. Colonoscopy showed active lesions in 45 cases and inactive lesions in 14 cases, in whom the percentages of increase of brightness were (90±32)% and (41±29)% respectively. At a threshold value of 45% for the percentage of increase of brightness, sensitivity, specificity and accuracy of predicting the severity at endoscopy were 95.6%, 78.6% and 91.5%, the Youden index was 0.74, and area under curve was 0.846. Quantitative measurement of bowel enhancement by using contrast-enhanced ultrasonography can discriminate between active and inactive Crohn disease at endoscopy. Contrast-enhanced ultrasonography may be a useful technique to monitor the activity of Crohn disease.

  2. Contrast-enhanced endoscopic ultrasonography: advance and current status

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Sung Il [Dept. of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of); Lee, Dong Ki [Dept. of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2014-10-15

    Endoscopic ultrasonography (EUS) technology has undergone a great deal of progress along with the color and power Doppler imaging, three-dimensional imaging, electronic scanning, tissue harmonic imaging, and elastography, and one of the most important developments is the ability to acquire contrast-enhanced images. The blood flow in small vessels and the parenchymal microvasculature of the target lesion can be observed non-invasively by contrast-enhanced EUS (CE-EUS). Through a hemodynamic analysis, CE-EUS permits the diagnosis of various gastrointestinal diseases and differential diagnoses between benign and malignant tumors. Recently, mechanical innovations and the development of contrast agents have increased the use of CE-EUS in the diagnostic field, as well as for the assessment of the efficacy of therapeutic agents. The advances in and the current status of CE-EUS are discussed in this review.

  3. Contrast-enhanced ultrasound for molecular imaging of angiogenesis.

    Science.gov (United States)

    Eisenbrey, J R; Forsberg, F

    2010-08-01

    Molecular imaging of angiogenesis using contrast-enhanced ultrasound allows for functional, real-time, inexpensive imaging of angiogenesis. The addition of stabilized microbubbles as contrast agents greatly improves ultrasound signal to noise ratio/signal strength/image quality (up to 25 dB) and allows for imaging of angiogenic vasculature. In this article recent advances in the usage of contrast-enhanced ultrasound for molecular imaging of angiogenesis are reviewed. The usage of commercially available agents and correlations between their imaging parameters and molecular markers of angiogenesis are reviewed. Recent developments in ultrasound contrast agents targeted to angiogenic markers for both diagnosis and monitoring are discussed. Finally, a brief overview of the emerging field of chemotherapeutic-loaded agents, which can be used with ultrasound-triggered drug delivery, is provided.

  4. Contrast enhanced ultrasound in the assessment of urogenital pathology

    Directory of Open Access Journals (Sweden)

    Libero Barozzi

    2014-12-01

    Full Text Available Contrast enhanced ultrasound (CEUS is an innovative technique that employs microbubble contrast agents to demonstrate parenchymal perfusion. Although initial clinical application was focused on the liver pathology, a wide variety of clinical conditions can be assessed now with CEUS. CEUS is a well-tolerated technique and is acquiring an increasing role in the assessment of renal pathology because contrast agents are not excreted by the kidney and do not affect the renal function. CEUS demonstrated an accuracy similar to contrast enhanced multi-detector computed tomography (CEMDCT in detecting focal lesions, with the advantage of the real-time assessment of microvascular perfusion by using time-intensity curves. The aim of this paper is to review the main indications of CEUS in the assessment of renal and urogenital pathology. Imaging examples are presented and described. Advantages and limitations of CEUS with reference to conventional US and CE-MDCT are discussed.

  5. Visualisation of contrast-enhanced intraoperative optical coherence tomography with indocyanine green.

    Science.gov (United States)

    Ehlers, Justis P; McNutt, Stephen; Dar, Suhail; Tao, Yuankai K; Srivastava, Sunil K

    2014-11-01

    Optical coherence tomography (OCT)-based visualisation of ophthalmic anatomy has transformed the clinical practice of ophthalmology. The translation of OCT into the surgical theatre is currently being actively researched and may provide a paradigm shift in surgical practice. Enhanced visualisation of tissues and tissue planes may provide further iterative improvement in surgeon feedback. Contrast-enhanced intraoperative OCT (iOCT) has been previously described with triamcinolone. In this report, we describe the OCT features and contrast enhancement noted with indocyanine green using iOCT in human subjects as well as an ex vivo analysis in porcine eyes. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Visual Contrast Enhancement Algorithm Based on Histogram Equalization

    Directory of Open Access Journals (Sweden)

    Chih-Chung Ting

    2015-07-01

    Full Text Available Image enhancement techniques primarily improve the contrast of an image to lend it a better appearance. One of the popular enhancement methods is histogram equalization (HE because of its simplicity and effectiveness. However, it is rarely applied to consumer electronics products because it can cause excessive contrast enhancement and feature loss problems. These problems make the images processed by HE look unnatural and introduce unwanted artifacts in them. In this study, a visual contrast enhancement algorithm (VCEA based on HE is proposed. VCEA considers the requirements of the human visual perception in order to address the drawbacks of HE. It effectively solves the excessive contrast enhancement problem by adjusting the spaces between two adjacent gray values of the HE histogram. In addition, VCEA reduces the effects of the feature loss problem by using the obtained spaces. Furthermore, VCEA enhances the detailed textures of an image to generate an enhanced image with better visual quality. Experimental results show that images obtained by applying VCEA have higher contrast and are more suited to human visual perception than those processed by HE and other HE-based methods.

  7. Contrast enhancement pattern in MR imaging of acute cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Deok; Cho, Mee Young; Lee, Chae Guk; Song, Dong Hoon [Inje University College of Medicine, Pusan (Korea, Republic of)

    1994-08-15

    To present the enhancement pattern of acute cerebral or cerebellar cortical infarctions aged 1-3 days on MR. Contrast-enhanced MR images of 26 patients with acute cerebral or cerebellar ischemic events were retrospectively reviewed. MR was performed within 3 days after ictus. Contrast enhancement in the area of infarction was observed in 61.5% (16/26) on MR. Of these 50% (13/26) showed non-parenchymal enhancement (NPE) representing either vascular or leptomeningeal enhancement, 7.7% (2/26) showed parenchymal enhancement (PE), and 2.8% (1/26) showed both NPE and PE. The earliest enhancement was seen in images obtained 12 hours after the onset of symptoms and appeared as NPE. One patient showed NPE without apparent high signal intensity at the corresponding area on T2-weighted images. In 38.5% (10/26), there was no enhancement. Contrast-enhanced MR imaging may be needed in acute ischemic infarction, because NPE may be seen as the earliest MR finding of acute cortical infraction aged 1-3 days.

  8. Visual Contrast Enhancement Algorithm Based on Histogram Equalization

    Science.gov (United States)

    Ting, Chih-Chung; Wu, Bing-Fei; Chung, Meng-Liang; Chiu, Chung-Cheng; Wu, Ya-Ching

    2015-01-01

    Image enhancement techniques primarily improve the contrast of an image to lend it a better appearance. One of the popular enhancement methods is histogram equalization (HE) because of its simplicity and effectiveness. However, it is rarely applied to consumer electronics products because it can cause excessive contrast enhancement and feature loss problems. These problems make the images processed by HE look unnatural and introduce unwanted artifacts in them. In this study, a visual contrast enhancement algorithm (VCEA) based on HE is proposed. VCEA considers the requirements of the human visual perception in order to address the drawbacks of HE. It effectively solves the excessive contrast enhancement problem by adjusting the spaces between two adjacent gray values of the HE histogram. In addition, VCEA reduces the effects of the feature loss problem by using the obtained spaces. Furthermore, VCEA enhances the detailed textures of an image to generate an enhanced image with better visual quality. Experimental results show that images obtained by applying VCEA have higher contrast and are more suited to human visual perception than those processed by HE and other HE-based methods. PMID:26184219

  9. Impact of model-based iterative reconstruction on image quality of contrast-enhanced neck CT.

    Science.gov (United States)

    Gaddikeri, S; Andre, J B; Benjert, J; Hippe, D S; Anzai, Y

    2015-02-01

    Improved image quality is clinically desired for contrast-enhanced CT of the neck. We compared 30% adaptive statistical iterative reconstruction and model-based iterative reconstruction algorithms for the assessment of image quality of contrast-enhanced CT of the neck. Neck contrast-enhanced CT data from 64 consecutive patients were reconstructed retrospectively by using 30% adaptive statistical iterative reconstruction and model-based iterative reconstruction. Objective image quality was assessed by comparing SNR, contrast-to-noise ratio, and background noise at levels 1 (mandible) and 2 (superior mediastinum). Two independent blinded readers subjectively graded the image quality on a scale of 1-5, (grade 5 = excellent image quality without artifacts and grade 1 = nondiagnostic image quality with significant artifacts). The percentage of agreement and disagreement between the 2 readers was assessed. Compared with 30% adaptive statistical iterative reconstruction, model-based iterative reconstruction significantly improved the SNR and contrast-to-noise ratio at levels 1 and 2. Model-based iterative reconstruction also decreased background noise at level 1 (P = .016), though there was no difference at level 2 (P = .61). Model-based iterative reconstruction was scored higher than 30% adaptive statistical iterative reconstruction by both reviewers at the nasopharynx (P iterative reconstruction. Model-based iterative reconstruction offers improved subjective and objective image quality as evidenced by a higher SNR and contrast-to-noise ratio and lower background noise within the same dataset for contrast-enhanced neck CT. Model-based iterative reconstruction has the potential to reduce the radiation dose while maintaining the image quality, with a minor downside being prominent artifacts related to thyroid shield use on model-based iterative reconstruction. © 2015 by American Journal of Neuroradiology.

  10. Assessment of irradiated brain metastases using dynamic contrast-enhanced magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Almeida-Freitas, Daniela B. [University of Sao Paulo, Department of Radiology, Sao Paulo (Brazil); University of California, Department of Radiology, San Diego, CA (United States); Pinho, Marco C. [University of Texas Southwestern Medical Center, Department of Radiology, Dallas, TX (United States); Otaduy, Maria C.G.; Costa Leite, Claudia da [University of Sao Paulo, Department of Radiology, Sao Paulo (Brazil); Braga, Henrique F. [University of Sao Paulo, Department of Radiotherapy, Sao Paulo (Brazil); Meira-Freitas, Daniel [Federal University of Sao Paulo, Sao Paulo (Brazil)

    2014-06-15

    The purpose of this study was to evaluate the effect of stereotactic radiosurgery (SRS) on cerebral metastases using the transfer constant (K{sub trans}) assessed by dynamic contrast-enhanced (DCE) MRI. Furthermore, we aimed to evaluate the ability of K{sub trans} measurements to predict midterm tumor outcomes after SRS. The study received institutional review board approval, and informed consent was obtained from all subjects. Twenty-six adult patients with a total of 34 cerebral metastases underwent T1-weighted DCE MRI in a 1.5-T magnet at baseline (prior to SRS) and 4-8 weeks after treatment. Quantitative analysis of DCE MRI was performed by generating K{sub trans} parametric maps, and region-of-interest-based measurements were acquired for each metastasis. Conventional MRI was performed at least 16 weeks after SRS to assess midterm tumor outcome using volume variation. The mean (±SD) K{sub trans} value was 0.13 ± 0.11 min{sup -1} at baseline and 0.08 ± 0.07 min{sup -1} after 4-8 weeks post-treatment (p < 0.001). The mean (±SD) total follow-up time was 7.9 ± 4.7 months. Seventeen patients (22 lesions) underwent midterm MRI. Of those, nine (41 %) lesions had progressed at the midterm follow-up. An increase in K{sub trans} after SRS was predictive of tumor progression (hazard ratio = 1.50; 95 % CI = 1.16-1.70, p < 0.001). An increase of 15 % in K{sub trans} showed a sensitivity of 78 % and a specificity of 85 % for the prediction of progression at midterm follow-up. SRS was associated with a reduction of K{sub trans} values of the cerebral metastases in the early post-treatment period. Furthermore, K{sub trans} variation as assessed using DCE MRI may be helpful to predict midterm outcomes after SRS. (orig.)

  11. Contrast-enhanced ultrasound features of histologically proven focal nodular hyperplasia: diagnostic performance compared with contrast-enhanced CT.

    Science.gov (United States)

    Wang, Wei; Chen, Li-Da; Lu, Ming-De; Liu, Guang-Jian; Shen, Shun-Li; Xu, Zuo-Feng; Xie, Xiao-Yan; Wang, Yan; Zhou, Lu-Yao

    2013-09-01

    To investigate and compare contrast-enhanced ultrasound (CEUS) in the characterisation of histologically proven focal nodular hyperplasia (FNH) with contrast-enhanced computed tomography (CECT). CEUS was performed in 85 patients with 85 histologically proven FNHs. Enhancement, centrifugal filling, spoke-wheel arteries, feeding artery and central scarring were reviewed and correlated with lesion size or liver background. Independent factors for predicting FNH from other focal liver lesions (FLLs) were evaluated. Forty-seven FLLs with CECT were randomly selected for comparison of diagnostic performance with CEUS. Centrifugal filling was more common (P = 0.002) and the significant predictor (P = 0.003) in FNHs ≤3 cm. Lesion size or liver background has no significant influence on the detection rate of the spoke-wheel arteries and feeding artery (P > 0.05). Central scarring was found in 42.6 % of FNHs ≥3 cm (P = 0.000). The area under the ROC curve, sensitivity and specificity showed no significant differences between CEUS and CECT (P > 0.05), except that the sensitivity of CEUS was better for reader 1 (P = 0.041). CEUS is valuable in characterising centrifugal filling signs or spoke wheels in small FNHs and should be employed as the first-line imaging technique for diagnosis of FNH. • The confident diagnosis of focal nodular hyperplasia is important in liver imaging. • The centrifugal filling sign is useful for diagnosis of FNHs ≤3 cm. • Contrast-enhanced ultrasound and contrast-enhanced CT have similar diagnostic performance for FNH. • CEUS should be the first-line imaging technique for the diagnosis of FNH.

  12. Agreement and disagreement between contrast-enhanced magnetic resonance imaging and nuclear imaging for assessment of myocardial viability

    Energy Technology Data Exchange (ETDEWEB)

    Roes, Stijntje D.; Kaandorp, Theodorus A.M.; Westenberg, Jos J.M.; Lamb, Hildo J.; Roos, Albert de [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Ajmone Marsan, Nina; Wall, Ernst E. van der; Bax, Jeroen J. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Dibbets-Schneider, Petra; Stokkel, Marcel P. [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands)

    2009-04-15

    The purpose of this study was to compare contrast-enhanced MRI and nuclear imaging with {sup 99m}Tc-tetrofosmin and {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) single photon emission computed tomography (SPECT) for assessment of myocardial viability. Included in the study were 60 patients with severe ischaemic left ventricular (LV) dysfunction who underwent contrast-enhanced MRI, {sup 99m}Tc-tetrofosmin and {sup 18}F-FDG SPECT. Myocardial segments were assigned a wall motion score from 0 (normokinesia) to 4 (dyskinesia) and a scar score from 0 (no scar) to 4 (76-100% transmural extent). Furthermore, {sup 99m}Tc-tetrofosmin and {sup 18}F-FDG segmental tracer uptake was categorized from 0 (tracer activity >75%) to 3 (tracer activity <25%). Dysfunctional segments were classified into viability patterns on SPECT: normal perfusion/{sup 18}F-FDG uptake, perfusion/{sup 18}F-FDG mismatch, and mild or severe perfusion/{sup 18}F-FDG match. Minimal scar tissue was observed on contrast-enhanced MRI (scar score 0.4{+-}0.8) in segments with normal perfusion/{sup 18}F-FDG uptake, whereas extensive scar tissue (scar score 3.1{+-}1.0) was noted in segments with severe perfusion/{sup 18}F-FDG match (p < 0.001). High agreement (91%) for viability assessment between contrast-enhanced MRI and nuclear imaging was observed in segments without scar tissue on contrast-enhanced MRI as well as in segments with transmural scar tissue (83%). Of interest, disagreement was observed in segments with subendocardial scar tissue on contrast-enhanced MRI. Agreement between contrast-enhanced MRI and nuclear imaging for assessment of viability was high in segments without scar tissue and in segments with transmural scar tissue on contrast-enhanced MRI. However, evident disagreement was observed in segments with subendocardial scar tissue on contrast-enhanced MRI, illustrating that the nonenhanced epicardial rim can contain either normal or ischaemically jeopardized myocardium. (orig.)

  13. EFFECT OF SEDATION ON CONTRAST-ENHANCED ULTRASONOGRAPHY OF THE SPLEEN IN HEALTHY DOGS.

    Science.gov (United States)

    Rossi, Federica; Fina, Caroline; Stock, Emmelie; Vanderperren, Katrien; Duchateau, Luc; Saunders, Jimmy H

    2016-05-01

    Contrast-enhanced ultrasound of the spleen enables the dynamic assessment of the perfusion of this organ, however, both subjective and quantitative evaluation can be strongly influenced by sedative agent administration. The purpose of this prospective, experimental study was to test effects of two sedative agents on splenic perfusion during contrast-enhanced ultrasound of the spleen in a sample of healthy dogs. Contrast-enhanced ultrasound of the spleen was repeated in six healthy Beagles following a cross-over study design comparing three protocols: awake, butorphanol 0.2 mg/Kg intramuscular (IM), and dexmedetomidine 500 μg/m(2) IM. After intravenous injection of a phospholipid stabilized sulfur hexafluoride microbubble solution (SonoVue®, Bracco Imaging, Milano, Italy), the enhancement intensity and perfusion pattern of the splenic parenchyma were assessed and perfusion parameters were calculated. Normal spleen was slightly heterogeneous in the early phase, but the parenchyma was homogeneous at a later phase. Sedation with butorphanol did not modify perfusion of the spleen. Dexmedetomidine significantly reduced splenic enhancement, providing diffuse parenchymal hypoechogenicity during the entire examination. Measured parameters were significantly modified, with increased arrival time (AT; (dogs. Short-term and diffuse heterogeneity of the spleen in the early venous phase was determined to be a normal finding. © 2016 American College of Veterinary Radiology.

  14. Quantitative flow phantom for contrast-enhanced breast tomosynthesis

    Science.gov (United States)

    Nock, Melissa L.; Kempston, Michael P.; Mainprize, James G.; Yaffe, Martin J.

    2007-03-01

    The use of contrast agents can help to overcome a lack of intrinsic radiographic contrast between malignant and benign breast tissue by taking advantage of the properties of tumour angiogenesis. Studies of contrast-enhanced mammography have demonstrated increased lesion conspicuity and have shown that this technique provides information on contrast uptake kinetics. It has been suggested that malignant and benign lesions can be differentiated in part by their uptake kinetics, so this additional data may lead to more accurate diagnoses. Tomosynthesis is a 3D x-ray imaging technique that permits lesion depth localization and increased conspicuity in comparison with 2D x-ray projection techniques. This modality, used in combination with contrast agents, promises to be a sensitive method of breast cancer detection. To develop the technique of contrast-enhanced breast tomosynthesis, a dynamic flow phantom has been constructed to provide the same types of imaging challenges anticipated in the clinical setting. These challenges include a low-contrast tumour space, relevant temporal contrast agent uptake and washout profiles, and a need for quantitative analysis of enhancement levels. The design of a flow phantom will be presented that includes a dynamic tumour space, a background that masks the tumour space in images without contrast enhancement, and flow characteristics that simulate tumour contrast agent uptake and washout kinetics. The system is calibrated to relate signal to concentration of the contrast agent using a well plate filled with iodinated water. Iodine detectability in the flow phantom is evaluated in terms of the signal-difference-to-noise ratio for various tomosynthesis image acquisition parameters including number of acquired angular views, angular extent, and reconstruction voxel size.

  15. Pancreatic splenosis demonstrated by contrast-enhanced sonography.

    Science.gov (United States)

    Rogers, Patrick; Williams, M P; Fernando, Rashika; Freeman, Simon

    2011-07-01

    Pancreatic splenosis is a very rare condition whose features on contrast-enhanced ultrasound (CEUS) have not, to our knowledge, been previously reported. We present the imaging findings in a case of pancreatic splenosis, in which a confident diagnosis was achieved with the use of CEUS and confirmed by a labeled heat denatured red cell scan. Accumulation of ultrasound contrast microbubbles in splenic tissue can be readily visualized on late-phase CEUS and this technique has already been used to confirm the nature of intrapancreatic accessory spleens. This case shows that it can also confirm the diagnosis of splenosis. Copyright © 2011 Wiley Periodicals, Inc.

  16. Prolapsed cervical disc with diffuse contrast enhancement on CT

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Jun; Shinpo, Tomoyuki; Inoue, Kiyoharu; Shigeno, Taku; Ochiai, Chikayuki

    1985-04-01

    A 48-year-old woman with the C5/6 disc herniation was reported. She had noticed vague pains in the left shoulder a half year earlier. Neurological examination showed left lower cervical radicular pains and incomplete Brown-Sequard syndrome of the same side. The disc herniation was diagnosed by myelography and discography. On the CT examination, surprisingly, the prolapsed disc was homogenously enhanced after the administration of intravenous contrast medium. The vertebral angiography showed increased vascularity behind the C5/6 intervertebral space. At operation, a prolapsed nucleus pulposus with proliferated connective tissue was found and curetted. The etiology of contrast enhancement was discussed.

  17. Contrast-enhanced ultrasonography revealed active thoracic bleeding.

    Science.gov (United States)

    Sugihara, Takaaki; Koda, Masahiko; Tokunaga, Shiho; Matono, Tomomitsu; Nagahara, Takakazu; Ueki, Masaru; Murawaki, Yoshikazu; Kaminou, Toshio

    2010-07-01

    A 61-year-old woman with a hepatocellular carcinoma located in the subphrenic region was treated by radiofrequency ablation (RFA) under artificial pleural effusion. During RFA, B-mode ultrasonography showed a swirling high echoic lesion in the artificial pleural effusion. A real-time scan performed using contrast-enhanced ultrasonography (CEUS) revealed a jet-like extravasation of contrast medium and pooling of microbubbles in the pleural cavity, which were confirmed by angiography. CEUS successfully identified the site of bleeding and can be regarded an effective tool for detecting active bleeding in an emergency.

  18. Recent Experiences and Advances in Contrast-Enhanced Subharmonic Ultrasound

    Directory of Open Access Journals (Sweden)

    John R. Eisenbrey

    2015-01-01

    Full Text Available Nonlinear contrast-enhanced ultrasound imaging schemes strive to suppress tissue signals in order to better visualize nonlinear signals from blood-pooling ultrasound contrast agents. Because tissue does not generate a subharmonic response (i.e., signal at half the transmit frequency, subharmonic imaging has been proposed as a method for isolating ultrasound microbubble signals while suppressing surrounding tissue signals. In this paper, we summarize recent advances in the use of subharmonic imaging in vivo. These advances include the implementation of subharmonic imaging on linear and curvilinear arrays, intravascular probes, and three-dimensional probes for breast, renal, liver, plaque, and tumor imaging.

  19. Recent Experiences and Advances in Contrast-Enhanced Subharmonic Ultrasound.

    Science.gov (United States)

    Eisenbrey, John R; Sridharan, Anush; Liu, Ji-Bin; Forsberg, Flemming

    2015-01-01

    Nonlinear contrast-enhanced ultrasound imaging schemes strive to suppress tissue signals in order to better visualize nonlinear signals from blood-pooling ultrasound contrast agents. Because tissue does not generate a subharmonic response (i.e., signal at half the transmit frequency), subharmonic imaging has been proposed as a method for isolating ultrasound microbubble signals while suppressing surrounding tissue signals. In this paper, we summarize recent advances in the use of subharmonic imaging in vivo. These advances include the implementation of subharmonic imaging on linear and curvilinear arrays, intravascular probes, and three-dimensional probes for breast, renal, liver, plaque, and tumor imaging.

  20. Quantitative Nonlinear Contrast-Enhanced Ultrasound of the Breast.

    Science.gov (United States)

    Sridharan, Anush; Eisenbrey, John R; Dave, Jaydev K; Forsberg, Flemming

    2016-08-01

    Breast cancer is the most frequent type of cancer among women (25% of all cancers). The angiogenic process that fuels the growth of tumors is a potential early indicator for differentiating between malignant and benign tumors. Recently, the use of microbubble-based contrast agents combined with ultrasound has allowed the development of contrast agent-specific imaging modes that provide visualization of tumor neovascularity. Contrast-enhanced Doppler, harmonic, and subharmonic imaging are some of the imaging modes that have been investigated for visualizing and quantifying the vascularity in breast tumors.

  1. A fuzzy approach for contrast enhancement of mammography breast images.

    Science.gov (United States)

    Sahba, Farhang; Venetsanopoulos, Anastasios

    2010-01-01

    This chapter presents a fuzzy-based method for contrast enhancement of mammography images. The selection of appropriate parameters for the required transformations is performed based on image-specific characteristics. The extraction of the breast border is the first step in this method. Images are then transformed to the fuzzy domain using a specific function. Next, an algorithm is applied for intensity adaptation where based on the amount of ambiguity, the proposed technique identifies the suitable form of modifications to enhance the image. Experimental results prove our method to be effective and hence of potential for use in computer-aided diagnosis systems.

  2. Contrast-enhanced Spectral Mammography: Technique, Indications, and Clinical Applications.

    Science.gov (United States)

    Bhimani, Chandni; Matta, Danielle; Roth, Robyn G; Liao, Lydia; Tinney, Elizabeth; Brill, Kristin; Germaine, Pauline

    2017-01-01

    Contrast-enhanced spectral mammography (CESM) combines the benefits of full field digital mammography with the concept of tumor angiogenesis. Technique and practical applications of CESM are discussed. An overview of the technique is followed by a demonstration of practical applications of CESM in our practice. We have successfully implemented CESM into our practice as a screening, diagnostic, staging, and treatment response tool. It is important to understand the technique of CESM and how to incorporate it into practice. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  3. Dynamic Contrast-Enhanced CT in Patients with Pancreatic Cancer

    DEFF Research Database (Denmark)

    Eriksen, Rie Ø; Strauch, Louise S; Sandgaard, Michael

    2016-01-01

    The aim of this systematic review is to provide an overview of the use of Dynamic Contrast-enhanced Computed Tomography (DCE-CT) in patients with pancreatic cancer. This study was composed according to the PRISMA guidelines 2009. The literature search was conducted in PubMed, Cochrane Library...... tissue, compared with measurements in pancreatic tissue outside of tumor, or normal pancreatic tissue in control groups of healthy volunteers. The studies were heterogeneous in the number of patients enrolled and scan protocols. Perfusion parameters measured and analyzed by DCE-CT might be useful...

  4. Artifacts in contrast-enhanced ultrasound: a pictorial essay.

    Science.gov (United States)

    Fetzer, David T; Rafailidis, Vasileios; Peterson, Cynthia; Grant, Edward G; Sidhu, Paul; Barr, Richard G

    2017-12-02

    Although contrast-enhanced ultrasound (CEUS) has become a widely utilized and accepted modality in much of the world, the associated contrast agents have only recently received approval in the United States. As with all radiological techniques, image artifacts are encountered in CEUS, some of which relate to commonly encountered ultrasound artifacts, while others are unique to this technique. Image artifacts must be recognized when performing and interpreting examinations to improve technique and diagnostic accuracy. In this article, we review artifacts that may be encountered in CEUS, and where possible discuss how to minimize them or mitigate their effect on image quality and interpretation.

  5. Contrast-enhanced Ultrasound for Non-tumor Liver Diseases

    Directory of Open Access Journals (Sweden)

    H Maruyama

    2012-03-01

    Full Text Available Contrast-enhanced ultrasound (CEUS is a simple, safe and reliable technique for the clinical management of patients with various liver diseases. Although the major target of the technique may be focal hepatic lesions, it is also effective for the diagnosis of non-tumor liver diseases, such as grading hepatic fibrosis, characterization of chronic liver diseases and diagnosis of portal vein thrombosis. This review article aimed to overview the recent application of CEUS in the assessment of non-tumor liver diseases. Keywords: Cirrhosis, contrast agent, fibrosis, idiopathic portal hypertension, microbubble, portal vein thrombosis, ultrasound.

  6. Optimal exposure techniques for iodinated contrast enhanced breast CT

    Science.gov (United States)

    Glick, Stephen J.; Makeev, Andrey

    2016-03-01

    Screening for breast cancer using mammography has been very successful in the effort to reduce breast cancer mortality, and its use has largely resulted in the 30% reduction in breast cancer mortality observed since 1990 [1]. However, diagnostic mammography remains an area of breast imaging that is in great need for improvement. One imaging modality proposed for improving the accuracy of diagnostic workup is iodinated contrast-enhanced breast CT [2]. In this study, a mathematical framework is used to evaluate optimal exposure techniques for contrast-enhanced breast CT. The ideal observer signal-to-noise ratio (i.e., d') figure-of-merit is used to provide a task performance based assessment of optimal acquisition parameters under the assumptions of a linear, shift-invariant imaging system. A parallel-cascade model was used to estimate signal and noise propagation through the detector, and a realistic lesion model with iodine uptake was embedded into a structured breast background. Ideal observer performance was investigated across kVp settings, filter materials, and filter thickness. Results indicated many kVp spectra/filter combinations can improve performance over currently used x-ray spectra.

  7. Molecular imaging with dynamic contrast-enhanced computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Miles, K.A., E-mail: k.a.miles@bsms.ac.u [Clinical Imaging Sciences Centre, Brighton and Sussex Medical School, University of Sussex, Falmer, Brighton (United Kingdom)

    2010-07-15

    Dynamic contrast-enhanced computed tomography (DCE-CT) is a quantitative technique that employs rapid sequences of CT images after bolus administration of intravenous contrast material to measure a range of physiological processes related to the microvasculature of tissues. By combining knowledge of the molecular processes underlying changes in vascular physiology with an understanding of the relationship between vascular physiology and CT contrast enhancement, DCE-CT can be redefined as a molecular imaging technique. Some DCE-CT derived parameters reflect tissue hypoxia and can, therefore, provide information about the cellular microenvironment. DCE-CT can also depict physiological processes, such as vasodilatation, that represent the physiological consequences of molecular responses to tissue hypoxia. To date the main applications have been in stroke and oncology. Unlike some other molecular imaging approaches, DCE-CT benefits from wide availability and ease of application along with the use of contrast materials and software packages that have achieved full regulatory approval. Hence, DCE-CT represents a molecular imaging technique that is applicable in clinical practice today.

  8. The Application of Contrast Enhanced Ultrasound in Molecular Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hak Jong; Chung, Jin Haeung; Hwang, Sung Il [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2009-09-15

    Microbubble contrast agent for ultrasound imaging has come of age, adding entirely new capabilities to real time ultrasound imaging. These new ultrasound imaging techniques exploit the nonlinear echoes that result from the unique interaction between ultrasound and microbubbles, which are readily distinguishable from the echoes of tissues. Contrast enhanced ultrasound can be used to quantify both flow rate and relative vascular volume of the microvasculature in solid lesions or organs, which makes it possible for it to be one of the modalities in molecular imaging. Angiogenesis is one of the important processes contributing to new blood vessel growth that occurs in a variety of physiologic and pathophysiologic states. It is essential for spread and growth of malignant tumors. The advantages of contrast enhanced ultrasound are that it is a noninvasive method for observing tumor angiogenesis. Sonoporation utilizes the interaction of ultrasound with ultrasound contrast agents to temporarily permeabilized the cell membrane allowing for the uptake of DNA, drugs, and other therapeutic compounds from the extracellular environment. Thus, sonoporation is a promising drug delivery and gene therapy technique, limited only by lack of understanding regarding the biophysical mechanism that results in the cell membrane permeability change. In conclusion, ultrasound contrast agent could have a role not only in the molecular imaging field with the advantage of noninvasive quantification of angiogenesis, but also in the field of drug treatment of cells using sonoporation

  9. Applications of contrast-enhanced ultrasound in the kidney.

    Science.gov (United States)

    Kazmierski, Brittany; Deurdulian, Corinne; Tchelepi, Hisham; Grant, Edward G

    2017-08-30

    Incidental discovery of renal lesions on cross-sectional imaging studies performed for other indications is not uncommon. With the increased reliance on medical imaging, the number of incidentally detected renal lesions has also grown over time. While simple cysts account for the majority of these lesions, the presence of complex features within a cystic lesion, such as septations and solid components, can present a confusing picture. Solid lesions, too, can be indeterminate, and distinguishing between benign solid masses (like lipid-poor angiomyolipomas and oncocytomas) and renal cell carcinoma affects patient management and can prevent unnecessary interventions. Indeterminate renal lesions are traditionally further characterized by multiphase imaging, such as contrast-enhanced computed tomography and magnetic resonance imaging. Contrast-enhanced ultrasound (CEUS) is a new, relatively inexpensive technique that has become increasingly employed in the diagnostic workup of indeterminate renal lesions. With its lack of nephrotoxicity, the absence of ionizing radiation, and the ability to evaluate the enhancement pattern of renal lesions quickly and in real-time, CEUS has unique advantages over traditional imaging modalities. This article provides an overview of the current clinical applications of CEUS in characterizing renal lesions, both cystic and solid. Additional applications of CEUS in the kidney, including its roles in renal transplant evaluation and guidance for percutaneous biopsy, will also be briefly discussed.

  10. Contrast enhanced imaging with a stationary digital breast tomosynthesis system

    Science.gov (United States)

    Puett, Connor; Calliste, Jabari; Wu, Gongting; Inscoe, Christina R.; Lee, Yueh Z.; Zhou, Otto; Lu, Jianping

    2017-03-01

    Digital breast tomosynthesis (DBT) captures some depth information and thereby improves the conspicuity of breast lesions, compared to standard mammography. Using contrast during DBT may also help distinguish malignant from benign sites. However, adequate visualization of the low iodine signal requires a subtraction step to remove background signal and increase lesion contrast. Additionally, attention to factors that limit contrast, including scatter, noise, and artifact, are important during the image acquisition and post-acquisition processing steps. Stationary DBT (sDBT) is an emerging technology that offers a higher spatial and temporal resolution than conventional DBT. This phantom-based study explored contrast-enhanced sDBT (CE sDBT) across a range of clinically-appropriate iodine concentrations, lesion sizes, and breast thicknesses. The protocol included an effective scatter correction method and an iterative reconstruction technique that is unique to the sDBT system. The study demonstrated the ability of this CE sDBT system to collect projection images adequate for both temporal subtraction (TS) and dual-energy subtraction (DES). Additionally, the reconstruction approach preserved the improved contrast-to-noise ratio (CNR) achieved in the subtraction step. Finally, scatter correction increased the iodine signal and CNR of iodine-containing regions in projection views and reconstructed image slices during both TS and DES. These findings support the ongoing study of sDBT as a potentially useful tool for contrast-enhanced breast imaging and also highlight the significant effect that scatter has on image quality during DBT.

  11. Contrast enhanced ultrasound features of hepatic cystadenoma and hepatic cystadenocarcinoma.

    Science.gov (United States)

    Dong, Yi; Wang, Wen-Ping; Mao, Feng; Fan, Mei; Ignee, Andre; Serra, Carla; Sparchez, Zeno; Sporea, Ioan; Braden, Barbara; Dietrich, Christoph F

    2017-03-01

    Hepatic (biliary) cystic tumor (HBCT) is a rare focal cystic liver lesion, which has been rarely described in the literature. In our current multicenter, retrospective study, we aimed to analyze contrast enhanced ultrasound (CEUS) features and its diagnostic performance in histologically proved HBCT. Twenty-three patients with single HBCT were retrospectively analyzed. Histologically, 17 (73.9%) were benign hepatic (biliary) cystadenoma (HBCA), 6 (26.1%) were hepatic (biliary) cystadenocarcinoma (HBCAC). All CEUS examinations were assessed by two independent radiologists in consensus. Criteria of CEUS imaging evaluation included the contrast enhancement pattern of lesion (hypoenhancing, hyperenhancing, isoenhancing in comparison to the surrounding liver parenchyma) during the arterial, portal venous and late phases. After injection of ultrasound contrast agents, most of the HBCTs (78.3%, 18/23) had typical honeycomb enhancement pattern of the cystic wall, septa or mural nodules. Comparing between HBCA and HBCAC, hyperenhancement of the honeycomb septa during the arterial phase was more common in HBCA (p = .047). However, hypoenhancement during the portal venous and late phases was the characteristic of HBCAC (p = .041). The EFSUMB algorithm for CEUS for characterization of solid focal liver lesions is also applicable to HBCT. CEUS evaluation can avoid further diagnostic investigations or invasive biopsy procedure.

  12. Blunt splenic trauma: can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    Science.gov (United States)

    Poletti, Pierre-Alexandre; Becker, Christoph D; Arditi, Daniel; Terraz, Sylvain; Buchs, Nicolas; Shanmuganathan, Kathirkamanathan; Platon, Alexandra

    2013-11-01

    To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48-72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. Blunt splenic trauma: Can contrast enhanced sonography be used for the screening of delayed pseudoaneurysms?

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, Pierre-Alexandre, E-mail: Pierre-Alexandre.Poletti@hcuge.ch [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Becker, Christoph D.; Arditi, Daniel; Terraz, Sylvain [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Buchs, Nicolas [Department of Surgery, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland); Shanmuganathan, Kathirkamanathan [Department of Diagnostic Radiology and Nuclear Medicine, 22 S. Greene Street, Baltimore, MD 21201 (United States); Platon, Alexandra [Department of Radiology, University Hospital of Geneva, 4 Rue Gabrielle Perret-Gentil, 1211 Geneva 14 (Switzerland)

    2013-11-01

    Purpose: To assess the value of contrast-enhanced sonography (CES) for the detection of delayed post-traumatic splenic pseudo-aneurysms, usually considered an indication for angiographic embolization. Methods: Sixty-three consecutive hemodynamically stable trauma patients in whom admission CT displayed a splenic injury of grade II or higher (AAST classification), without evidence of vascular involvement, were included in the study. CES of the spleen using a second generation contrast agent was systematically performed within 48–72 h after admission, for the detection of a pooling of contrast media suggestive of pseudoaneurysm. Within 6 h after contrast-enhanced sonography, all patients underwent an abdominal CT for control purposes. CES results were compared to CT findings, which were considered the reference standard. This study received approval from the institutional ethical board. Results: CES showed a blush of contrast consistent with a pseudoaneurysm in 6 of the 63 patients. All were confirmed at subsequent control CT. Pooling of contrast was found at CT in 2 patients in whom contrast-enhanced sonography was negative. There was no false positive CES examination for the suspicion of pseudoaneurysms. When compared to CT, the sensitivity, specificity, positive and negative predictive values of CES to suggest a pseudoaneurysms, were 75% (6/8), 100% (55/55), 100% (6/6), and 96% (55/57), respectively. Conclusion: Our data suggest that CES may be useful for the screening of delayed traumatic splenic pseudoaneurysms: if a negative CES does not absolutely rule out a pseudoaneurysm, a positive CES warrants an angiography, without need of control CT.

  14. Semi-automatic motion compensation of contrast-enhanced ultrasound images from abdominal organs for perfusion analysis

    Czech Academy of Sciences Publication Activity Database

    Schafer, S.; Nylund, K.; Saevik, F.; Engjom, T.; Mézl, M.; Jiřík, Radovan; Dimcevski, G.; Gilja, O.H.; Tönnies, K.

    2015-01-01

    Roč. 63, AUG 1 (2015), s. 229-237 ISSN 0010-4825 R&D Projects: GA ČR GAP102/12/2380 Institutional support: RVO:68081731 Keywords : ultrasonography * motion analysis * motion compensation * registration * CEUS * contrast-enhanced ultrasound * perfusion * perfusion modeling Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 1.521, year: 2015

  15. Evaluating automated dynamic contrast enhanced wrist 3T MRI in healthy volunteers

    DEFF Research Database (Denmark)

    Rastogi, Anshul; Kubassova, Olga; Krasnosselskaia, Lada V

    2013-01-01

    Dynamic contrast enhanced (DCE)-MRI has great potential to provide quantitative measure of inflammatory activity in rheumatoid arthritis. There is no current benchmark to establish the stability of signal in the joints of healthy subjects when imaged with DCE-MRI longitudinally, which is crucial so...... as to differentiate changes induced by treatment from the inherent variability of perfusion measures. The objective of this study was to test a pixel-by-pixel parametric map based approach for analysis of DCE-MRI (Dynamika) and to investigate the variability in signal characteristics over time in healthy controls...

  16. Incidental focal solid liver lesions: diagnostic performance of contrast-enhanced ultrasound and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Soussan, Michael [Hopital Beaujon, Department of Radiology, Assistance Publique des Hopitaux de Paris, APHP, Clichy (France); Aube, Christophe [CHU Angers, Department of Radiology, Angers (France); Laboratoire HIFIH, Angers (France); Bahrami, Stephane [Universite Paris-Dauphine, Department of Medical Statistics, Assistance Publique des Hopitaux de Paris, APHP, Paris (France); Boursier, Jerome [CHU Angers, Department of Hepatogastroenterology and Laboratoire HIFIH, Angers (France); Valla, Dominique Charles [Universite Paris-7 Denis Diderot, Paris (France); INSERM Centre de recherche Biomedicale Bichat Beaujon, Paris (France); Hopital Beaujon, Department of Hepatology, Assistance Publique des Hopitaux de Paris, APHP, Clichy (France); Vilgrain, Valerie [Hopital Beaujon, Department of Radiology, Assistance Publique des Hopitaux de Paris, APHP, Clichy (France); Universite Paris-7 Denis Diderot, Paris (France); INSERM Centre de recherche Biomedicale Bichat Beaujon, Paris (France)

    2010-07-15

    To prospectively assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) and MR imaging in incidental solid focal liver lesions not characterised on ultrasound. Forty-seven patients with 50 lesions underwent MR imaging and CEUS: 24 focal nodular hyperplasias (FNH), 11 adenomas, 10 haemangiomas, 1 focal fatty change and 4 malignant lesions were identified. Two experienced radiologists randomly reviewed contrast-enhanced MR imaging and CEUS data, and provided the most likely diagnosis. Sensitivity (Se), specificity (Sp), likelihood ratios (LR) and kappa value were calculated. A histotype diagnosis was obtained in 66-52% with MR imaging and 52-53% with CEUS, respectively, for both readers. Se, Sp and LR for haemangioma were 100-100, 100-100 and 78-78 with MR imaging and 89-89, 100-100 and 68-70 with CEUS; for FNH with MR imaging they were 88-63, 96-100 and 23-34 and 74-67, 88-96 and 6-17 with CEUS. If the diagnosis of haemangioma was uncertain with CEUS, MR imaging always confirmed the diagnosis. If the diagnosis of FNH was uncertain with either CEUS or MR imaging, the other imaging technique confirmed the diagnosis in approximately half the cases. Both CEUS and MR imaging have a high diagnostic performance in incidental focal liver lesions and are complementary when diagnosis is uncertain. (orig.)

  17. Renal masses - evaluation by amplitude coded colour Doppler sonography and multiphasic contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Riccabona, M.; Szolar, D.; Preidler, K.; Uggowitzer, M.; Kugler, C.; Doerfler, O.; Schreyer, H.H. [Graz Univ. (Austria). Dept. of Radiology

    1999-07-01

    Objective: To assess the efficacy of amplitude coded colour Doppler US (aCDS) in the evaluation of renal masses as shown by multiphasic contrast-enhanced CT. Material and methods: Eighty patients (155 kidneys) with suspicion of renal masses underwent aCDS and spiral CT. The findings were classified into normal kidneys, kidneys with tumours, kidneys with cysts, and those with `other findings` (i.e. bleeding, calcifications, inflammation, parenchymal hypertrophy). The aCDS findings were compared to CT results and to histological findings or clinical, laboratory and follow-up data. Results: Eighteen renal cell carcinomas and 8 other tumours were found; 78 kidneys had cysts, 12 polycystic kidneys and 10 fibrotic kidneys were detected, 20 kidneys showed other findings. Diagnostic aCDS data were obtained in 129 kidneys (83.2%) showing pathology with an accuracy of 94%. CT adequately showed pathology in all patients with some diagnostic uncertainty in the evaluation of complicated cysts. Conclusion: Though contrast-enhanced multiphasic spiral CT is the method of choice for evaluating renal masses, US including aCDS can provide valuable information, particularly in differentiating vascularized from non-vascularized lesions and in the evaluation of complicated renal cysts. (orig.)

  18. Small-bowel MRI in children and young adults with Crohn disease: retrospective head-to-head comparison of contrast-enhanced and diffusion-weighted MRI.

    Science.gov (United States)

    Neubauer, Henning; Pabst, Thomas; Dick, Anke; Machann, Wolfram; Evangelista, Laura; Wirth, Clemens; Köstler, Herbert; Hahn, Dietbert; Beer, Meinrad

    2013-01-01

    Small-bowel MRI based on contrast-enhanced T1-weighted sequences has been challenged by diffusion-weighted imaging (DWI) for detection of inflammatory bowel lesions and complications in patients with Crohn disease. To evaluate free-breathing DWI, as compared to contrast-enhanced MRI, in children, adolescents and young adults with Crohn disease. This retrospective study included 33 children and young adults with Crohn disease ages 17 ± 3 years (mean ± standard deviation) and 27 matched controls who underwent small-bowel MRI with contrast-enhanced T1-weighted sequences and DWI at 1.5 T. The detectability of Crohn manifestations was determined. Concurrent colonoscopy as reference was available in two-thirds of the children with Crohn disease. DWI and contrast-enhanced MRI correctly identified 32 and 31 patients, respectively. All 22 small-bowel lesions and all Crohn complications were detected. False-positive findings (two on DWI, one on contrast-enhanced MRI), compared to colonoscopy, were a result of large-bowel lumen collapse. Inflammatory wall thickening was comparable on DWI and contrast-enhanced MRI. DWI was superior to contrast-enhanced MRI for detection of lesions in 27% of the assessed bowel segments and equal to contrast-enhanced MRI in 71% of segments. DWI facilitates fast, accurate and comprehensive workup in Crohn disease without the need for intravenous administration of contrast medium. Contrast-enhanced MRI is superior in terms of spatial resolution and multiplanar acquisition.

  19. Contrast-enhanced ultrasound features of histologically proven focal nodular hyperplasia: diagnostic performance compared with contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wei; Chen, Li-Da; Liu, Guang-Jian; Xu, Zuo-Feng; Xie, Xiao-Yan; Wang, Yan; Zhou, Lu-Yao [The First Affiliated Hospital of Sun Yat-Sen University Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Department of Medical Ultrasonics, Guangzhou (China); Lu, Ming-De [The First Affiliated Hospital of Sun Yat-Sen University Institute of Diagnostic and Interventional Ultrasound, Sun Yat-Sen University, Department of Medical Ultrasonics, Guangzhou (China); The First Affiliated Hospital of Sun Yat-Sen University, Department of Hepatobiliary Surgery, Guangzhou (China); Shen, Shun-Li [The First Affiliated Hospital of Sun Yat-Sen University, Department of Hepatobiliary Surgery, Guangzhou (China)

    2013-09-15

    To investigate and compare contrast-enhanced ultrasound (CEUS) in the characterisation of histologically proven focal nodular hyperplasia (FNH) with contrast-enhanced computed tomography (CECT). CEUS was performed in 85 patients with 85 histologically proven FNHs. Enhancement, centrifugal filling, spoke-wheel arteries, feeding artery and central scarring were reviewed and correlated with lesion size or liver background. Independent factors for predicting FNH from other focal liver lesions (FLLs) were evaluated. Forty-seven FLLs with CECT were randomly selected for comparison of diagnostic performance with CEUS. Centrifugal filling was more common (P = 0.002) and the significant predictor (P = 0.003) in FNHs {<=}3 cm. Lesion size or liver background has no significant influence on the detection rate of the spoke-wheel arteries and feeding artery (P > 0.05). Central scarring was found in 42.6 % of FNHs {>=}3 cm (P = 0.000). The area under the ROC curve, sensitivity and specificity showed no significant differences between CEUS and CECT (P > 0.05), except that the sensitivity of CEUS was better for reader 1 (P = 0.041). CEUS is valuable in characterising centrifugal filling signs or spoke wheels in small FNHs and should be employed as the first-line imaging technique for diagnosis of FNH. (orig.)

  20. Contrast enhancing solution for use in confocal microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Tannous, Zeina; Torres, Abel; Gonzalez, Salvador

    2006-10-31

    A method of optically detecting a tumor during surgery. The method includes imaging at least one test point defined on the tumor using a first optical imaging system to provide a first tumor image. The method further includes excising a first predetermined layer of the tumor for forming an in-vivo defect area. A predetermined contrast enhancing solution is disposed on the in-vivo defect area, which is adapted to interact with at least one cell anomaly, such as basal cell carcinoma, located on the in-vivo defect area for optically enhancing the cell anomaly. Thereafter the defect area can be optically imaged to provide a clear and bright representation of the cell anomaly to aid a surgeon while surgically removing the cell anomaly.

  1. BLIND CONTRAST ENHANCEMENT ASSESSMENT BY GRADIENT RATIOING AT VISIBLE EDGES

    Directory of Open Access Journals (Sweden)

    Nicolas Hautière

    2011-05-01

    Full Text Available The contrast of outdoor images acquired under adverse weather conditions, especially foggy weather, is altered by the scattering of daylight by atmospheric particles. As a consequence, differentmethods have been designed to restore the contrast of these images. However, there is a lack of methodology to assess the performances of the methods or to rate them. Unlike image quality assessment or image restoration areas, there is no easy way to have a reference image, which makes the problem not straightforward to solve. In this paper, an approach is proposed which consists in computing the ratio between the gradient of the visible edges between the image before and after contrast restoration. In this way, an indicator of visibility enhancement is provided based on the concept of visibility level, commonly used in lighting engineering. Finally, the methodology is applied to contrast enhancement assessment and to the comparison of tone-mapping operators.

  2. Contrast-Enhanced Ultrasound in Vascular Surgery: Review and Update

    DEFF Research Database (Denmark)

    Bredahl, Kim; Mestre, Xavier Marti; Coll, Ramon Vila

    2017-01-01

    are easy to use, manageable, and safe. This topical review attempts to summarize and highlight the current evidence and future prospects for contrast-enhanced ultrasound in vascular surgery, with a particular focus on opportunities in carotid and lower limb arteriosclerotic disease and surveillance after......Accurate imaging methods associated with minimum patient risk are important tools for clinical decision-making in vascular surgery. Today, traditional imaging methods, such as computed tomography angiography, magnetic resonance angiography, and digital subtraction angiography are the preferred...... modalities. Ultrasound has only challenged these methods in assessment of carotid disease, aortic aneurysms, venous insufficiency, and thromboembolism and in surveillance of in situ bypasses. These practice patterns may change with the introduction of second-generation ultrasound contrast agents which...

  3. Value of contrast-enhanced ultrasound in rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Zordo, Tobias de; Mlekusch, Sabine P.; Feuchtner, Gudrun M. [Department of Radiology II, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck (Austria); Mur, Erich [Department of Internal Medicine, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck (Austria); Schirmer, Michael [Department of Internal Medicine, Hospital of the Elisabethines Klagenfurt, Voelkermarkter Strasse 15-19, 9020 Klagenfurt (Austria); Klauser, Andrea S. [Department of Radiology II, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck (Austria)], E-mail: andrea.klauser@i-med.ac.at

    2007-11-15

    The purpose of this review is to describe the spectrum of sonographic findings in rheumatic diseases with respect to the diagnostic potential using US contrast media which prove activity or inactivity in synovial tissue where new treatment regimes target. Synovial activity can be found in non-erosive and erosive forms of primary and secondary osteoarthritis, and in inflammatory forms of joint diseases like rheumatoid arthritis and peripheral manifestations of spondyloarthritis including, ankylosing spondylitis, Reiter's syndrome, psoriatic arthritis and enteropathic arthritis. It can also be present in metabolic and endocrine forms of arthritis, in connective tissue arthropathies like systemic lupus erythematosus or scleroderma and in infectious arthritis. Ultrasound should be used as first-line imaging modality in suspected early cases of RA and other forms of arthritis, whereas contrast-enhanced ultrasound (CEUS) can further enable for sensitive assessment of vascularity which correlates with disease activity.

  4. Quantitative contrast-enhanced mammography for contrast medium kinetics studies.

    Science.gov (United States)

    Arvanitis, C D; Speller, R

    2009-10-21

    Quantitative contrast-enhanced mammography, based on a dual-energy approach, aims to extract quantitative and temporal information of the tumour enhancement after administration of iodinated vascular contrast media. Simulations using analytical expressions and optimization of critical parameters essential for the development of quantitative contrast-enhanced mammography are presented. The procedure has been experimentally evaluated using a tissue-equivalent phantom and an amorphous silicon active matrix flat panel imager. The x-ray beams were produced by a tungsten target tube and spectrally shaped using readily available materials. Measurement of iodine projected thickness in mg cm(-2) has been performed. The effect of beam hardening does not introduce nonlinearities in the measurement of iodine projected thickness for values of thicknesses found in clinical investigations. However, scattered radiation introduces significant deviations from slope equal to unity when compared with the actual iodine projected thickness. Scatter correction before the analysis of the dual-energy images provides accurate iodine projected thickness measurements. At 10% of the exposure used in clinical mammography, signal-to-noise ratios in excess of 5 were achieved for iodine projected thicknesses less than 3 mg cm(-2) within a 4 cm thick phantom. For the extraction of temporal information, a limited number of low-dose images were used with the phantom incorporating a flow of iodinated contrast medium. The results suggest that spatial and temporal information of iodinated contrast media can be used to indirectly measure the tumour microvessel density and determine its uptake and washout from breast tumours. The proposed method can significantly improve tumour detection in dense breasts. Its application to perform in situ x-ray biopsy and assessment of the oncolytic effect of anticancer agents is foreseeable.

  5. Vascular applications of contrast-enhanced ultrasound imaging.

    Science.gov (United States)

    Mehta, Kunal S; Lee, Jake J; Taha, Ashraf A; Avgerinos, Efthymios; Chaer, Rabih A

    2017-07-01

    Contrast-enhanced ultrasound (CEUS) imaging is a powerful noninvasive modality offering numerous potential diagnostic and therapeutic applications in vascular medicine. CEUS imaging uses microbubble contrast agents composed of an encapsulating shell surrounding a gaseous core. These microbubbles act as nearly perfect intravascular reflectors of ultrasound energy and may be used to enhance the overall contrast and quality of ultrasound images. The purpose of this narrative review is to survey the current literature regarding CEUS imaging and discuss its diagnostic and therapeutic roles in current vascular and selected nonvascular applications. The PubMed, MEDLINE, and Embase databases were searched until July 2016 using the PubMed and Ovid Web-based search engines. The search terms used included contrast-enhanced, microbubble, ultrasound, carotid, aneurysm, and arterial. The diagnostic and therapeutic utility of CEUS imaging has grown exponentially, particularly in the realms of extracranial carotid arterial disease, aortic disease, and peripheral arterial disease. Studies have demonstrated that CEUS imaging is diagnostically superior to conventional ultrasound imaging in identifying vessel irregularities and measuring neovascularization to assess plaque vulnerability and end-muscle perfusion. Groups have begun to use microbubbles as agents in therapeutic applications for targeted drug and gene therapy delivery as well as for the enhancement of sonothrombolysis. The emerging technology of microbubbles and CEUS imaging holds considerable promise for cardiovascular medicine and cancer therapy given its diagnostic and therapeutic utility. Overall, with proper training and credentialing of technicians, the clinical implications are innumerable as microbubble technology is rapidly bursting onto the scene of cardiovascular medicine. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  6. Contrast Enhancement of Mammograms for Rapid Detection of Microcalcification Clusters

    Directory of Open Access Journals (Sweden)

    Hajar Moradmand

    2014-08-01

    Full Text Available Introduction Breast cancer is one of the most common types of cancer among women.  Early detection of breast cancer is the key to reducing the associated mortality rate. The presence of microcalcifications clusters (MCCs is one of the earliest signs of breast cancer. Due to poor imaging contrast of mammograms and noise contamination, radiologists may overlook some diagnostic signs, specially the presence of MCCs. In order to improve cancer detection, image enhancement methods are often used to aid radiologists. In this paper, a new enhancement method was presented for the accurate and early detection of MCCs in mammograms. Materials and Methods The proposed system consisted of four main steps including: 1 image scaling;2 breast region segmentation;3 noise cancellation using a filter, which is sensitive to MCCs; and 4 contrast enhancement of mammograms using Contrast-Limited Adaptive Histogram Equalization (CLAHE and wavelet transform. To evaluate this method, 120 clinical mammograms were used. Results To evaluate the performance of the image enhancement algorithm, contrast improvement index (CII was used. The proposed enhancement method in this research achieved the highest CII in comparison with other methods applied in this study. The Validity of the results was confirmed by an expert radiologist through visual inspection. Conclusion Detection of MCCs significantly improved in contrast-enhanced mammograms. The proposed method could be helpful for radiologists to easily detect MCCs; it could also decrease the number of biopsies and reduce the frequency of clinical misdiagnosis. Moreover, it could be useful prior to segmentation or classification stages.

  7. Contrast-enhanced ultrasonography to diagnose complicated acute cholecystitis.

    Science.gov (United States)

    Sagrini, Elisabetta; Pecorelli, Anna; Pettinari, Irene; Cucchetti, Alessandro; Stefanini, Federico; Bolondi, Luigi; Piscaglia, Fabio

    2016-02-01

    Gangrenous cholecystitis and perforation are severe complications of acute cholecystitis, which have a challenging preoperative diagnosis. Early identification allows better surgical management. Contrast-enhanced computed tomography (ceCT) is the current diagnostic gold standard. Contrast-enhanced ultrasonography (CEUS) is a promising tool for the diagnosis of gallbladder perforation, but data from the literature concerning efficacy are sparse. The aim of the study was to evaluate CEUS findings in pathologically proven complicated cholecystitis (gangrenous, perforated gallbladder, pericholecystic abscess). A total of 8 patients submitted to preoperative CEUS, and with subsequent proven acute complicated cholecystitis at surgical inspection and pathological analysis, were retrospectively identified. The final diagnosis was gangrenous/phlegmonous cholecystitis (n. 2), phlegmonous/ulcerative changes plus pericholecystic abscess (n. 2), perforated plus pericholecystic abscess (n. 3), or perforated plus pericholecystic biliary collection (n. 1). Conventional US findings revealed irregularly thickened gallbladder walls in all 8 patients, with vaguely defined walls in 7 patients, four of whom also had striated wall thickening. CEUS revealed irregular enhancing gallbladder walls in all patients. A distinct wall defect was seen in six patients, confirmed as gangrenous/phlegmonous cholecystitis at pathology in all six, and in four as perforation at macroscopic surgical inspection. CEUS is a non-invasive easily repeatable technique that can be performed at the bedside, and is able to accurately diagnose complicated/perforated cholecystitis. Despite the limited sample size in the present case series, CEUS appears as a promising tool for the management of patients with the clinical possibility of having an acute complicated cholecystitis.

  8. Malignant transformation of branch duct-type intraductal papillary mucinous neoplasms of the pancreas based on contrast-enhanced endoscopic ultrasonography morphological changes: focus on malignant transformation of intraductal papillary mucinous neoplasm itself.

    Science.gov (United States)

    Ohno, Eizaburo; Itoh, Akihiro; Kawashima, Hiroki; Ishikawa, Takuya; Matsubara, Hiroshi; Itoh, Yuya; Nakamura, Yosuke; Hiramatsu, Takeshi; Nakamura, Masanao; Miyahara, Ryoji; Ohmiya, Naoki; Ishigami, Masatoshi; Katano, Yoshiaki; Goto, Hidemi; Hirooka, Yoshiki

    2012-08-01

    The natural history of branch duct-type intraductal papillary mucinous neoplasms (BD-IPMNs) of the pancreas remains unclear. We conducted a retrospective long-term follow-up study for malignant transformation (MT) of BD-IPMNs focusing on morphological changes. The subjects consisted of 142 patients who underwent contrast-enhanced endoscopic ultrasonography for initial diagnosis from January 2001 with more than 12 months of follow-up. The MT rate, including the co-occurrence of invasive ductal cancer, was evaluated by univariate and multivariate analysis. In addition, on the basis of morphological changes in patients who underwent surgery, the predictive factors for malignant IPMNs were evaluated. Median follow-up term was 42.5 months (range, 12-105 months). Thirty patients who exhibited morphological changes underwent surgery. Malignant transformation occurred in 9 patients (6.3%), and 5-year MT rate was 10.7%. The co-occurrence of invasive ductal cancer was seen in 5 patients. Multivariate analysis showed that the existence of mural nodules at initial diagnosis and involvement of main pancreatic duct were significant predictors of MT of BD-IPMN. Malignant transformation of BD-IPMN is not rare. The observation of morphological changes of main pancreatic duct and nodules, mainly on contrast-enhanced endoscopic ultrasonography, is practical and useful for predicting MT of BD-IPMN itself.

  9. Normal breast parenchyma: contrast enhancement kinetics at dynamic MR mammography--influence of anthropometric measures and menopausal status.

    Science.gov (United States)

    Hegenscheid, Katrin; Schmidt, Carsten O; Seipel, Rebecca; Laqua, René; Ohlinger, Ralf; Kühn, Jens-Peter; Hosten, Norbert; Puls, Ralf

    2013-01-01

    To study T1 baseline signal intensity (SI) and contrast material enhancement kinetics of normal breast parenchyma by using dynamic contrast-enhanced (DCE) magnetic resonance (MR) mammography and to determine the influence of anthropometric measures and menopausal status on the variability of these features. Institutional review board approval and written informed consent were obtained. Between June 2008 and September 2011, 345 women (age range, 26-81 years; mean age, 51.3 years ± 11.6 [standard deviation]) underwent DCE MR mammography, with T1-weighted three-dimensional MR images (repetition time msec/echo time msec, 8.86/4.51; flip angle, 25°) acquired with a 1.5-T whole-body MR unit before and 1, 2, 3, 4, and 5 minutes after a gadobutrol bolus injection of 0.1 mmol per kilogram of body weight. Regions of interest were traced manually, and T1 SI of parenchyma was recorded. The influence of different predictors of T1 baseline SI and contrast enhancement was studied by using random-effects models. T1 baseline SI varied considerably between women, with a mean of 167.7 ± 49.2 (71.4-424.7 [range]) and 175.9 ± 48.9 (51.8-458.3) in the right and the left breast, respectively (P contrast material delivery, relative percentage of enhancement was 8.1%, 13.8%, 18.2%, 22.1%, and 24.6% at 1, 2, 3, 4, and 5 minutes, respectively, but varied considerably between women. Contrast enhancement was 9.3% in the lowest quintile and 47.4% in the highest. Contrast enhancement increased with body weight (P contrast enhancement slope. Anthropometric measures and menopausal status contribute to a large variability in contrast enhancement of normal breast parenchyma. This might influence the interpretation of contrast enhancement kinetics of breast lesions and current strategies for determining contrast medium dose for breast MR imaging. RSNA, 2012

  10. Breast Cancer Preoperative Staging: Does Contrast-Enhanced Magnetic Resonance Mammography Modify Surgery?

    Directory of Open Access Journals (Sweden)

    Chiara Perono Biacchiardi

    2011-01-01

    Full Text Available Women with newly diagnosed breast cancer may have lesions undetected by conventional imaging. Recently contrast-enhanced magnetic resonance mammography (CE-MRM showed higher sensitivity in breast lesions detection. The present analysis was aimed at evaluating the benefit of preoperative CE-MRM in the surgical planning. From 2005 to 2009, 525 consecutive women (25–75 years with breast cancer, newly diagnosed by mammography, ultrasound, and needle-biopsy, underwent CE-MRM. The median invasive tumour size was 19 mm. In 144 patients, CE-MRM identified additional lesions. After secondlook, 119 patients underwent additional biopsy. CE-MRM altered surgery in 118 patients: 57 received double lumpectomy or wider excision (41 beneficial, 41 required mastectomy (40 beneficial, and 20 underwent contra lateral surgery (18 beneficial. The overall false-positive rate was 27.1% (39/144. CE-MRM contributed significantly to the management of breast cancer, suggesting more extensive disease in 144/525 (27.4% patients and changing the surgical plan in 118/525 (22.5% patients (99/525, 18.8% beneficial.

  11. Contrast-enhanced ultrasound using sulfur hexafluoride is safe in the pediatric setting.

    Science.gov (United States)

    Torres, Alvaro; Koskinen, Seppo K; Gjertsen, Henrik; Fischler, Björn

    2017-11-01

    Background Contrast-enhanced ultrasound (CEUS) by using sulfur hexafluoride microbubbles is not licensed for use in children, but its off-label use is widespread. Purpose To outline our experience with the off-label use of CEUS in children, specifically with regards to safety. Material and Methods We retrieved all records of 10681 patients aged under 18 years who underwent abdominal ultrasound (US) January 2004 to December 2014. We then identified those who underwent an abdominal CEUS using sulfur hexafluoride microbubbles. Electronic patient charts were used to verify the indication for contrast agent, dose, possible adverse effects as well as information on patient height, weight, and age. Results We identified 173 patients (mean age, 11 years; range, 0.1-18 years) who underwent a total of 287 CEUS exams. Of all exams, 46% were performed on the native liver, 31% on a transplanted liver, and 23% on other organs. The indications were "circulatory status?" (40%), "characterization of lesion?" (40%), and miscellaneous (20%). Mean contrast dose was 2.3 mL (range, 0.1-8.1 mL). No immediate adverse effects were recorded. One patient experienced itching the day after, but this was considered to be a reaction to concomitantly administered fentanyl. Conclusion The use of intravenous ultrasound contrast seems safe in patients aged under 18 years and our results do not support the current practice to restrict the use of CEUS in children.

  12. Detection of thrombosis in the portal venous system: comparison of contrast-enhanced MR angiography with intraarterial digital subtraction angiography.

    Science.gov (United States)

    Kreft, B; Strunk, H; Flacke, S; Wolff, M; Conrad, R; Gieseke, J; Pauleit, D; Bachmann, R; Hirner, A; Schild, H H

    2000-07-01

    To determine whether intraarterial digital subtraction angiography (DSA) can be replaced by contrast material-enhanced magnetic resonance (MR) angiography in the assessment of patency or thrombosis of the portal venous system in patients with portal hypertension. Thirty-six patients with portal hypertension underwent contrast-enhanced MR angiography and intraarterial DSA for assessment of the portal venous system. The images were evaluated for vessel patency or thrombosis of the portal, splenic, or superior mesenteric vein. Of the 101 vessels evaluated, 42 were thrombosed. Overall sensitivity, specificity, and accuracy for the detection of thrombosis were 100%, 98%, and 99%, respectively, for MR angiography and 91%, 100%, and 96%, respectively, for DSA; differences between the imaging methods were not statistically significant. Only in four patients with six vessels (6%) were there discordant findings between MR angiography and DSA. Noninvasive contrast-enhanced MR angiography has the potential to replace intraarterial DSA as the standard method to assess the whole portal venous system.

  13. Cumulative phase delay imaging for contrast-enhanced ultrasound tomography

    Science.gov (United States)

    Demi, Libertario; van Sloun, Ruud J. G.; Wijkstra, Hessel; Mischi, Massimo

    2015-11-01

    Standard dynamic-contrast enhanced ultrasound (DCE-US) imaging detects and estimates ultrasound-contrast-agent (UCA) concentration based on the amplitude of the nonlinear (harmonic) components generated during ultrasound (US) propagation through UCAs. However, harmonic components generation is not specific to UCAs, as it also occurs for US propagating through tissue. Moreover, nonlinear artifacts affect standard DCE-US imaging, causing contrast to tissue ratio reduction, and resulting in possible misclassification of tissue and misinterpretation of UCA concentration. Furthermore, no contrast-specific modality exists for DCE-US tomography; in particular speed-of-sound changes due to UCAs are well within those caused by different tissue types. Recently, a new marker for UCAs has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental component is in fact observable for US propagating through UCAs, and is absent in tissue. In this paper, tomographic US images based on CPD are for the first time presented and compared to speed-of-sound US tomography. Results show the applicability of this marker for contrast specific US imaging, with cumulative phase delay imaging (CPDI) showing superior capabilities in detecting and localizing UCA, as compared to speed-of-sound US tomography. Cavities (filled with UCA) which were down to 1 mm in diameter were clearly detectable. Moreover, CPDI is free of the above mentioned nonlinear artifacts. These results open important possibilities to DCE-US tomography, with potential applications to breast imaging for cancer localization.

  14. Assessment of subclinical atherosclerosis using contrast-enhanced ultrasound.

    Science.gov (United States)

    van den Oord, Stijn C H; ten Kate, Gerrit L; Akkus, Zeynettin; Renaud, Guillaume; Sijbrands, Eric J G; ten Cate, Folkert J; van der Lugt, Aad; Bosch, Johan G; de Jong, Nico; van der Steen, Antonius F W; Schinkel, Arend F L

    2013-01-01

    The sensitivity of standard carotid ultrasound and colour Doppler for the detection of subclinical atherosclerotic plaques is suboptimal. The aim of this study is to assess whether contrast-enhanced ultrasound (CEUS) added to standard carotid ultrasound improves the detection of subclinical atherosclerosis. Carotid intima-media thickness (CIMT) measurement, standard carotid ultrasound including colour Doppler imaging, and CEUS were performed in 100 asymptomatic patients with one or more risk factors for atherosclerosis. CEUS was performed using intravenous administration of SonoVue™ contrast agent (Bracco S.p.A., Milan, Italy). CIMT, standard ultrasound, colour Doppler, and CEUS were reviewed by two independent observers. Standard ultrasound, colour Doppler, and CEUS were scored for the presence of atherosclerotic plaques. Subclinical atherosclerosis was diagnosed if patients had a CIMT above their age-corrected threshold value or if atherosclerotic plaques were present on standard carotid ultrasound clips or CEUS clips. McNemar's test was performed to compare between groups. Twenty-one patients (21%) had a thickened CIMT value and were considered to have subclinical atherosclerosis. Standard carotid ultrasound including colour Doppler demonstrated atherosclerotic plaques in 77 patients (77%). The addition of CEUS to the standard ultrasound protocol demonstrated atherosclerotic plaques in 88 patients (88%). The incorporation of CEUS into the standard carotid ultrasound protocol resulted in a significantly improved detection of patients with subclinical atherosclerosis (P subclinical atherosclerosis in the carotid arteries. Atherosclerotic plaques which were only detected with CEUS and not with standard carotid ultrasound and colour Doppler imaging were predominantly hypoechoic.

  15. Comparison between breast MRI and contrast-enhanced spectral mammography.

    Science.gov (United States)

    Łuczyńska, Elżbieta; Heinze-Paluchowska, Sylwia; Hendrick, Edward; Dyczek, Sonia; Ryś, Janusz; Herman, Krzysztof; Blecharz, Paweł; Jakubowicz, Jerzy

    2015-05-12

    The main goal of this study was to compare contrast-enhanced spectral mammography (CESM) and breast magnetic resonance imaging (MRI) with histopathological results and to compare the sensitivity, accuracy, and positive and negative predictive values for both imaging modalities. After ethics approval, CESM and MRI examinations were performed in 102 patients who had suspicious lesions described in conventional mammography. All visible lesions were evaluated independently by 2 experienced radiologists using BI-RADS classifications (scale 1-5). Dimensions of lesions measured with each modality were compared to postoperative histopathology results. There were 102 patients entered into CESM/MRI studies and 118 lesions were identified by the combination of CESM and breast MRI. Histopathology confirmed that 81 of 118 lesions were malignant and 37 were benign. Of the 81 malignant lesions, 72 were invasive cancers and 9 were in situ cancers. Sensitivity was 100% with CESM and 93% with breast MRI. Accuracy was 79% with CESM and 73% with breast MRI. ROC curve areas based on BI-RADS were 0.83 for CESM and 0.84 for breast MRI. Lesion size estimates on CESM and breast MRI were similar, both slightly larger than those from histopathology. Our results indicate that CESM has the potential to be a valuable diagnostic method that enables accurate detection of malignant breast lesions, has high negative predictive value, and a false-positive rate similar to that of breast MRI.

  16. Image fusion for dynamic contrast enhanced magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Leach Martin O

    2004-10-01

    Full Text Available Abstract Background Multivariate imaging techniques such as dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI have been shown to provide valuable information for medical diagnosis. Even though these techniques provide new information, integrating and evaluating the much wider range of information is a challenging task for the human observer. This task may be assisted with the use of image fusion algorithms. Methods In this paper, image fusion based on Kernel Principal Component Analysis (KPCA is proposed for the first time. It is demonstrated that a priori knowledge about the data domain can be easily incorporated into the parametrisation of the KPCA, leading to task-oriented visualisations of the multivariate data. The results of the fusion process are compared with those of the well-known and established standard linear Principal Component Analysis (PCA by means of temporal sequences of 3D MRI volumes from six patients who took part in a breast cancer screening study. Results The PCA and KPCA algorithms are able to integrate information from a sequence of MRI volumes into informative gray value or colour images. By incorporating a priori knowledge, the fusion process can be automated and optimised in order to visualise suspicious lesions with high contrast to normal tissue. Conclusion Our machine learning based image fusion approach maps the full signal space of a temporal DCE-MRI sequence to a single meaningful visualisation with good tissue/lesion contrast and thus supports the radiologist during manual image evaluation.

  17. Newly Diagnosed Breast Cancer: Comparison of Contrast-enhanced Spectral Mammography and Breast MR Imaging in the Evaluation of Extent of Disease.

    Science.gov (United States)

    Lee-Felker, Stephanie A; Tekchandani, Leena; Thomas, Mariam; Gupta, Esha; Andrews-Tang, Denise; Roth, Antoinette; Sayre, James; Rahbar, Guita

    2017-11-01

    Purpose To compare the diagnostic performances of contrast material-enhanced spectral mammography and breast magnetic resonance (MR) imaging in the detection of index and secondary cancers in women with newly diagnosed breast cancer by using histologic or imaging follow-up as the standard of reference. Materials and Methods This institutional review board-approved, HIPAA-compliant, retrospective study included 52 women who underwent breast MR imaging and contrast-enhanced spectral mammography for newly diagnosed unilateral breast cancer between March 2014 and October 2015. Of those 52 patients, 46 were referred for contrast-enhanced spectral mammography and targeted ultrasonography because they had additional suspicious lesions at MR imaging. In six of the 52 patients, breast cancer had been diagnosed at an outside institution. These patients were referred for contrast-enhanced spectral mammography and targeted US as part of diagnostic imaging. Images from contrast-enhanced spectral mammography were analyzed by two fellowship-trained breast imagers with 2.5 years of experience with contrast-enhanced spectral mammography. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated for both imaging modalities and compared by using the Bennett statistic. Results Fifty-two women with 120 breast lesions were included for analysis (mean age, 50 years; range, 29-73 years). Contrast-enhanced spectral mammography had similar sensitivity to MR imaging (94% [66 of 70 lesions] vs 99% [69 of 70 lesions]), a significantly higher PPV than MR imaging (93% [66 of 71 lesions] vs 60% [69 of 115 lesions]), and fewer false-positive findings than MR imaging (five vs 45) (P contrast-enhanced spectral mammography depicted 11 of the 11 secondary cancers (100%) and MR imaging depicted 10 (91%). Conclusion Contrast-enhanced spectral mammography is potentially as sensitive as MR imaging in the evaluation of extent of disease in newly diagnosed

  18. Radiofrequency thermal ablation of hepatocellular carcinoma: using contrast-enhanced harmonic power doppler sonography to assess treatment outcome.

    Science.gov (United States)

    Cioni, D; Lencioni, R; Rossi, S; Garbagnati, F; Donati, F; Crocetti, L; Bartolozzi, C

    2001-10-01

    We evaluated the accuracy of contrast-enhanced harmonic power Doppler sonography in assessing the outcome of radiofrequency thermal ablation of hepatocellular carcinoma. Fifty patients with 65 hepatocellular carcinoma nodules (1-5 cm in diameter; mean diameter, 2.5 cm) were studied using unenhanced and contrast-enhanced harmonic power Doppler sonography before and after IV administration of a microbubble contrast agent. The examinations were repeated after treatment of the tumors with radiofrequency ablation. Findings of the Doppler studies were compared with those of dual-phase helical CT, which were used as points of reference for assessing treatment outcome. Before radiofrequency treatment, intratumoral blood flow was revealed by unenhanced power Doppler sonography in 48 (74%) of 65 hepatocellular carcinoma nodules. After injection of the contrast agent, intratumoral enhancement was observed in 61 (94%) of 65 hepatocellular carcinomas (p enhancement on power Doppler sonograms. In nine of the 10 lesions that showed a residual viable tumor on helical CT scans, persistent intratumoral enhancement-matching the enhancing areas on helical CT images-was revealed by power Doppler sonography. These nine hepatocellular carcinomas were subjected to repeated radiofrequency thermal ablation with the guidance of contrast-enhanced power Doppler sonography. Complete necrosis was seen after the second treatment session in six of the nine lesions. Contrast-enhanced harmonic power Doppler sonography is an accurate technique for assessing the outcome of radiofrequency thermal ablation of hepatocellular carcinoma and may be useful in guiding additional treatment in patients with incomplete response to initial efforts.

  19. TMJ disorders and pain: Assessment by contrast-enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Farina, Davide [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy)], E-mail: nappaje@yahoo.it; Bodin, Christiane [Division of Gnathology (School of Dentistry), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); Gandolfi, Silvia [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); De Gasperi, Werner [Division of Gnathology (School of Dentistry), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy); Borghesi, Andrea; Maroldi, Roberto [Department of Radiology (School of Medicine), University of Brescia, Piazzale Spedali Civili 1, 25123 Brescia (Italy)

    2009-04-15

    Though magnetic resonance (MRI) is a widely accepted standard for the assessment of patients with temporomandibular joint (TMJ) disorders, efforts to correlate symptoms to MRI findings have often given controversial results. Aim of this study was to investigate the correlation between TMJ pain and findings of contrast-enhanced MRI. Thirty-eight consecutive patients with TMJ dysfunction syndrome (study group) were examined with MRI. Protocol included T2 turbo spin-echo sequence, T1 spin-echo sequence, and T2 gradient-echo (acquired with closed jaw, at intermediate and maximal opening). Post-contrast phase was obtained through a fat sat 3D T1 gradient-echo sequence (VIBE). Post-contrast findings in the study group were matched with those obtained in a control group of 33 patients submitted to MRI of the paranasal sinuses. Statistically significant difference was found between condylar medullary bone enhancement in painful TMJ, in painless TMJ and control group. In addition the average thickness of joint soft tissue enhancement in painful TMJ was superior to painless TMJ (p < 0.0001) and to control group. On multivariate logistic regression analysis, the odds ratio that a painful TMJ showed disk displacement, osteoarthrosis, effusion and JST enhancement were 3.05, 3.18, 1.2 and 11.36, respectively. Though not histologically proven, TMJ enhancement could reflect the presence of inflammation in painful joints. Furthermore, the administration of contrast could be of help for the assessment of patients with orofacial pain, particularly when clinical exploration is insufficient to ascribe the pain to TMJ.

  20. Contrast-enhanced peripheral MRA. Technique and contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Yousef W. [Dept. of Radiology, Copenhagen Univ. Hospital Bispebjerg, Bispebjerg (Denmark)], e-mail: ywnielsen@gmail.com; Thomsen, Henrik S. [Dept. of Diagnostic Radiology, Copenhagen Univ. Hospital Herlev, Herlev (Denmark)

    2012-09-15

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  1. Cumulative phase delay imaging - A new contrast enhanced ultrasound modality

    Energy Technology Data Exchange (ETDEWEB)

    Demi, Libertario, E-mail: l.demi@tue.nl; Sloun, Ruud J. G. van; Mischi, Massimo [Lab. of Biomedical Diagnostics, Dept. of Electrical Eng., Eindhoven University of Technology (Netherlands); Wijkstra, Hessel [Lab. of Biomedical Diagnostics, Dept. of Electrical Eng., Eindhoven University of Technology (Netherlands); Academic Medical Center, Urology Dept., University of Amsterdam (Netherlands)

    2015-10-28

    Recently, a new acoustic marker for ultrasound contrast agents (UCAs) has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental pressure wave field components is in fact observable for ultrasound propagating through UCAs. This phenomenon is absent in the case of tissue nonlinearity and is dependent on insonating pressure and frequency, UCA concentration, and propagation path length through UCAs. In this paper, ultrasound images based on this marker are presented. The ULA-OP research platform, in combination with a LA332 linear array probe (Esaote, Firenze Italy), were used to image a gelatin phantom containing a PVC plate (used as a reflector) and a cylindrical cavity measuring 7 mm in diameter (placed in between the observation point and the PVC plate). The cavity contained a 240 µL/L SonoVueO{sup ®} UCA concentration. Two insonating frequencies (3 MHz and 2.5 MHz) were used to scan the gelatine phantom. A mechanical index MI = 0.07, measured in water at the cavity location with a HGL-0400 hydrophone (Onda, Sunnyvale, CA), was utilized. Processing the ultrasound signals backscattered from the plate, ultrasound images were generated in a tomographic fashion using the filtered back-projection method. As already observed in previous studies, significantly higher CPD values are measured when imaging at a frequency of 2.5 MHz, as compared to imaging at 3 MHz. In conclusion, these results confirm the applicability of the discussed CPD as a marker for contrast imaging. Comparison with standard contrast-enhanced ultrasound imaging modalities will be the focus of future work.

  2. Contrast-enhanced ultrasonographic findings of hepatic paragonimiasis.

    Science.gov (United States)

    Lu, Qiang; Ling, Wen-Wu; Ma, Lin; Huang, Zi-Xing; Lu, Chang-Li; Luo, Yan

    2013-04-07

    To investigate the features of hepatic paragonimiasis on contrast-enhanced ultrasound (CEUS) imaging. Fifteen patients with hepatic paragonimiasis who were admitted to our hospital between March 2008 and August 2012 were enrolled to this study. The conventional ultrasound and CEUS examinations were performed with a Philips IU22 scanner with a 1-5-MHz convex transducer. After conventional ultrasound scanning was completed, the CEUS study was performed. Pulse inversion harmonic imaging was used for CEUS. A bolus injection of 2.4 mL of a sulfur hexafluoride-filled microbubble contrast agent (SonoVue) was administered. CEUS features were retrospectively reviewed and correlated with pathological findings. In total, 16 lesions were detected on CEUS. The mean size of the lesions was 4.4 ± 1.6 cm (range, 1.7-6.6 cm). Subcapsular location was found in 12 lesions (75%). All the lesions were hypoechoic. Six lesions (37.5%) were of mixed content, seven (43.8%) were solid with small cystic areas, and the other three (18.8%) were completely solid. Ten lesions (62.5%) were rim enhanced with irregular tract-like nonenhanced internal areas. Transient wedge-shaped hyperenhancement of the surrounding liver parenchyma was seen in seven lesions (43.8%). Areas with hyper- or iso-enhancement in the arterial phase showed contrast wash-out and appeared hypoenhanced in the late phase. The main pathological findings included: (1) coagulative or liquefactive necrosis within the lesion, infiltration of a large number of eosinophils with the formation of chronic eosinophilic abscesses and sporadic distribution of Charcot-Leyden crystals; and (2) hyperplasia of granulomatous and fibrous tissue around the lesion. Subcapsular location, hypoechogenicity, rim enhancement and tract-like nonenhanced areas could be seen as the main CEUS features of hepatic paragonimiasis.

  3. Contrast-enhanced ultrasound for liver imaging: recent advances.

    Science.gov (United States)

    Salvatore, Veronica; Borghi, Alberto; Piscaglia, Fabio

    2012-01-01

    Contrast-enhanced ultrasonography (CEUS), providing relevant informations not available with non-enhanced ultrasonography, greatly impacted the practice of liver imaging. The characterization of focal liver lesions (FLLs), is obtained in a rapid, accurate and safe way and is considered the main hepatic indication; however CEUS offers other established or emergent relevant applications. Metastases detection and assessment of response to locoregional tumor treatment are accepted applications with specific indications. Needle guidance in case of poorly or non visible target lesions at conventional ultrasound is also accepted. The early assessment of response to systemic treatment, and in particular to antiangiogenic ones, by quantification software is an emergent application. The manageability of CEUS determined also its use in the operating theatre, improving the accuracy of intraoperatory US with a significant impact on final surgical strategy. In cirrhotic patients, the role of CEUS was proven highly accurate and sensitive in the characterization of portal vein thrombosis, by identification of contrast arterial enhancement inside the thrombus, that occurs only in case of neoplastic origin. In recent years microbubbles taken up by Kupffer cells, thus possessing a "postvascular" phase, were registered as ultrasound contrast agent in Japan (Sonazoid). During the post-vascular phase tumoral tissue tend to appear as a contrast defect image due to the lack of Kupffer cells, strongly contributing to tumor staging beside characterization. Newly developed techniques, such as fusion imaging or real-time three dimensional US, in addition to other applications of CEUS, in terms of post-transplantation or cholecystitis-related complications, have been recently proposed and will be discussed.

  4. Contrast-enhanced ultrasonographic findings of hepatic paragonimiasis

    Science.gov (United States)

    Lu, Qiang; Ling, Wen-Wu; Ma, Lin; Huang, Zi-Xing; Lu, Chang-Li; Luo, Yan

    2013-01-01

    AIM: To investigate the features of hepatic paragonimiasis on contrast-enhanced ultrasound (CEUS) imaging. METHODS: Fifteen patients with hepatic paragonimiasis who were admitted to our hospital between March 2008 and August 2012 were enrolled to this study. The conventional ultrasound and CEUS examinations were performed with a Philips IU22 scanner with a 1-5-MHz convex transducer. After conventional ultrasound scanning was completed, the CEUS study was performed. Pulse inversion harmonic imaging was used for CEUS. A bolus injection of 2.4 mL of a sulfur hexafluoride-filled microbubble contrast agent (SonoVue) was administered. CEUS features were retrospectively reviewed and correlated with pathological findings. RESULTS: In total, 16 lesions were detected on CEUS. The mean size of the lesions was 4.4 ± 1.6 cm (range, 1.7-6.6 cm). Subcapsular location was found in 12 lesions (75%). All the lesions were hypoechoic. Six lesions (37.5%) were of mixed content, seven (43.8%) were solid with small cystic areas, and the other three (18.8%) were completely solid. Ten lesions (62.5%) were rim enhanced with irregular tract-like nonenhanced internal areas. Transient wedge-shaped hyperenhancement of the surrounding liver parenchyma was seen in seven lesions (43.8%). Areas with hyper- or iso-enhancement in the arterial phase showed contrast wash-out and appeared hypoenhanced in the late phase. The main pathological findings included: (1) coagulative or liquefactive necrosis within the lesion, infiltration of a large number of eosinophils with the formation of chronic eosinophilic abscesses and sporadic distribution of Charcot-Leyden crystals; and (2) hyperplasia of granulomatous and fibrous tissue around the lesion. CONCLUSION: Subcapsular location, hypoechogenicity, rim enhancement and tract-like nonenhanced areas could be seen as the main CEUS features of hepatic paragonimiasis. PMID:23599629

  5. The forgotten organ: Contrast enhanced sonography of the spleen

    Energy Technology Data Exchange (ETDEWEB)

    Goerg, Christian [Medizinische Universitaetsklinik, Baldingerstrasse, 35043 Marburg/Lahn (Germany)], E-mail: goergc@med.uni-marburg.de

    2007-11-15

    Objective: Ultrasound contrast agents in conjunction with contrast specific imaging techniques, are increasingly accepted in clinical use for diagnostic imaging in several organs. Contrast enhanced sonography (CES) of second-generation contrast media have shown a spleen-specific uptake of the microbubble contrast agent. The aim of this review is to illustrate indications for the use of CES in patients with suspected (peri-)splenic pathology. Methods: This review based on the experience of transcutaneous CES in 200 patients with (peri-)splenic pathology diagnosed by B-mode sonography at an internal medicine center. CES studies were performed with a contrast-devoted unit (Acuson, Sequoia, Siemens medical solution) that had contrast-specific, continuous-mode software. A low mechanical index was used. A sulfur hexafluoride-based microbubble contrast medium (Sonovue, Bracco SpA, Milan, Italy) was injected. Results: On our experience, there are several clinical conditions which may show an diagnostic advantage of CES in comparison to B-mode US. CES should be performed to investigate: (1) the perisplenic tumor to diagnose or exclude accessory spleen, (2) the small-sized spleen to diagnose functional asplenia/hyposplenia, (3) the inhomogenous spleen of unknown cause to diagnose focal lesions within the spleen, (4) the incidentally found hypoechoic splenic tumor to diagnose high vascular splenic hemangioma, (5) focal lesions suspect for splenic abscess, hematoma, infarction to confirme diagnosis, and (6) patients with abdominal trauma to diagnose or exclude splenic injuriy. Conclusion: CES is of diagnostic value in several clinical circumstances to diagnose accessory spleen, functional asplenia, small-sized splenic involvement, high vascular splenic hemangioma, and vascular splenic pathology like splenic infarction, splenic abscess, and splenic laceration.

  6. Detection of bleeding in patients with major pelvic fractures: value of contrast-enhanced CT.

    Science.gov (United States)

    Cerva, D S; Mirvis, S E; Shanmuganathan, K; Kelly, I M; Pais, S O

    1996-01-01

    We performed a retrospective review of trauma patients who had undergone both pelvic angiography and preangiographic i.v. contrast-enhanced CT to determine whether CT can accurately demonstrate the presence or absence of pelvic bleeding in patients with multisystem trauma and major pelvic fractures. We reviewed the medical records and imaging studies of all patients, identified through a trauma radiology database, who had undergone pelvic angiography and preangiographic contrast-enhanced CT during a 48-month period. Results of CT scans were recorded by consensus interpretation of three radiologists without knowledge of angiographic findings. Sites of contrast material extravasation seen on CT scans were noted and compared with sites of bleeding or vascular injury identified by selective pelvic angiography. Thirty patients with blunt trauma and pelvic fractures underwent both pelvic angiography and preangiographic CT studies. Findings on pelvic angiograms were positive at 26 sites in 19 patients and included contrast agent extravasation at 23 sites and vessel abnormalities without extravasation at three sites. Preangiographic pelvic CT scans showed contrast agent extravasation at 20 sites in 16 patients. Three patients had no contrast agent extravasation demonstrated by CT but had bleeding demonstrated by angiography. CT detected bleeding in 16 of 19 patients who had extravasation or vascular injury demonstrated by angiography, for a sensitivity of 84%. Results of pelvic angiography were negative in 11 patients, and none had evidence of bleeding on preangiographic CT scans. Two sites of contrast agent extravasation identified in two patients by CT did not show bleeding at angiography, for a specificity of 85% for the detection of bleeding. The overall accuracy of CT for determining the presence or absence of bleeding was 90%. Knowledge of sites of ongoing hemorrhage is crucial for optimizing the sequence of diagnostic and therapeutic studies in patients with blunt

  7. Contrast-enhanced ultrasound diagnosis of splenic artery steal syndrome after orthotopic liver transplantation.

    Science.gov (United States)

    Zhu, Xian-Sheng; Gao, Yun-Hua; Wang, Sha-Sha; Cheng, Qi; Ling, Yin; Fan, Li; Huo, Feng; Pu, Miao-Shui; Li, Peng

    2012-08-01

    The aim of this study was to investigate the use of contrast-enhanced ultrasound (CEUS) for the detection of splenic artery steal syndrome (SASS) after orthotopic liver transplantation (OLT). Two hundred forty-seven patients underwent OLT. Blood tests and color Doppler flow imaging (CDFI) were performed at various time points after the operation. CEUS and celiac angiography were used for patients suspected of having SASS. If the diagnosis of SASS was confirmed, splenic artery embolization was performed to enhance hepatic artery flow. CEUS and angiography were performed for the assessment of postinterventional clinical outcomes. Three of the 247 patients died postoperatively, and 8 patients were suspected of having SASS because of elevated liver enzyme levels and slim or undetectable hepatic artery blood signals by CDFI at various points after the operation. In these 8 patients, CEUS showed a delayed and weak contrast-enhanced blood signal in the hepatic artery associated with a rapid and intense enhancement of the portal vein blood. No narrowing of the hyperintense signal was observed in the hepatic artery by CEUS. The 8 diagnoses of SASS were proven by celiac angiography, which showed delayed perfusion of the hepatic artery and rapid filling of the splenic artery. Immediately after the interventional procedure, CEUS demonstrated a significantly enlarged hyperintense blood signal in the hepatic artery. In conclusion, approximately 3.27% of SASS cases occur after OLT. SASS can be identified as a sluggish and weak hyperintense blood signal in the hepatic artery without the narrowing and interruption of the hypointense signal in CEUS imaging. CEUS is an effective imaging modality for the detection of SASS after OLT. Copyright © 2012 American Association for the Study of Liver Diseases.

  8. Contrast-enhanced ultrasound of the kidney: a single-institution experience.

    Science.gov (United States)

    Oon, Sheng F; Foley, Robert W; Quinn, Deirdre; Quinlan, David M; Gibney, Robert G

    2017-12-07

    Focal renal masses are typically evaluated by means of triphasic contrast-enhanced CT or MRI scan but use of iodinated contrast or gadolinium is unsuitable for some patients. Contrast-enhanced ultrasound (CEUS) is an imaging alternative in this scenario but has limited availability in Ireland. The aim of the study was to retrospectively evaluate experience with selective use of CEUS for non-invasive characterization of focal renal masses in a tertiary referral institution in Ireland, with a particular focus on cystic renal lesions and the influence of CEUS on final Bosniak classification and treatment outcomes. All cases of renal CEUS between 2009 and 2017 were identified. Imaging history, patient records, histopathology reports, urology conference notes, clinical follow-up details, details of lesion progression or stability on surveillance, biopsy and/or resection details and pre- and post-CEUS Bosniak scores were recorded. Thirty-one patients underwent renal CEUS (7 solid renal lesions, 21 cystic renal lesions and 3 'indeterminate' renal lesions). After CEUS, the CEUS-modified Bosniak score was upgraded in nine patients and downgraded in two patients. All three lesions upgraded from Bosniak III to IV were renal cell carcinomas. One of two lesions downgraded from Bosniak IV to III was resected (cystic nephroma) and the other showed no progression after 19 months of surveillance. CEUS is a valuable alternative to CT in assessing complex cystic or solid renal lesions where iodinated CT contrast or gadolinium is inappropriate. CEUS can also refine the Bosniak category of atypical cystic renal lesions and help facilitate treatment decisions.

  9. Dual-energy contrast-enhanced digital mammography: initial clinical results of a multireader, multicase study.

    Science.gov (United States)

    Dromain, Clarisse; Thibault, Fabienne; Diekmann, Felix; Fallenberg, Eva M; Jong, Roberta A; Koomen, Marcia; Hendrick, R Edward; Tardivon, Anne; Toledano, Alicia

    2012-06-14

    The purpose of this study was to compare the diagnostic accuracy of dual-energy contrast-enhanced digital mammography (CEDM) as an adjunct to mammography (MX) ± ultrasonography (US) with the diagnostic accuracy of MX ± US alone. One hundred ten consenting women with 148 breast lesions (84 malignant, 64 benign) underwent two-view dual-energy CEDM in addition to MX and US using a specially modified digital mammography system (Senographe DS, GE Healthcare). Reference standard was histology for 138 lesions and follow-up for 12 lesions. Six radiologists from 4 institutions interpreted the images using high-resolution softcopy workstations. Confidence of presence (5-point scale), probability of cancer (7-point scale), and BI-RADS scores were evaluated for each finding. Sensitivity, specificity and ROC curve areas were estimated for each reader and overall. Visibility of findings on MX ± CEDM and MX ± US was evaluated with a Likert scale. The average per-lesion sensitivity across all readers was significantly higher for MX ± US ± CEDM than for MX ± US (0.78 vs. 0.71 using BIRADS, p = 0.006). All readers improved their clinical performance and the average area under the ROC curve was significantly superior for MX ± US ± CEDM than for MX ± US ((0.87 vs 0.83, p = 0.045). Finding visibility was similar or better on MX ± CEDM than MX ± US in 80% of cases. Dual-energy contrast-enhanced digital mammography as an adjunct to MX ± US improves diagnostic accuracy compared to MX ± US alone. Addition of iodinated contrast agent to MX facilitates the visualization of breast lesions.

  10. Image Quality and Stenosis Assessment of Non-Contrast-Enhanced 3-T Magnetic Resonance Angiography in Patients with Peripheral Artery Disease Compared with Contrast-Enhanced Magnetic Resonance Angiography and Digital Subtraction Angiography.

    Science.gov (United States)

    Liu, Jiayi; Zhang, Nan; Fan, Zhaoyang; Luo, Nan; Zhao, Yike; Bi, Xiaoming; An, Jing; Chen, Zhong; Liu, Dongting; Wen, Zhaoying; Fan, Zhanming; Li, Debiao

    2016-01-01

    To evaluate the diagnostic performance of flow-sensitive dephasing (FSD)-prepared steady-state free precession (SSFP) magnetic resonance angiography (MRA) at 3 T for imaging infragenual arteries relative to contrast-enhanced MRA (CE-MRA) and digital subtraction angiography (DSA). A series of 16 consecutive patients with peripheral arterial disease (PAD) underwent a combined peripheral MRA protocol consisting of FSD-MRA for the calves and large field-of-view CE-MRA. DSA was performed on all patients within 1 week of the MR angiographies. Image quality and degree of stenosis was assessed by two readers with rich experience. Inter-observer agreement was determined using kappa statistics. Receiver operating characteristic (ROC) curve analysis determined the diagnostic value of FSD-MRA, CE-MRA, and CE-MRA combined with FSD-MRA (CE+FSD MRA) in predicting vascular stenosis. At the calf station, no significantly difference of subjective image quality scores was found between FSD-MRA and CE-MRA. Inter-reader agreement was excellent for both FSD-MRA and CE-MRA. Both of FSD-MRA and CE-MRA carry a stenosis overestimation risk relative to DSA standard. With DSA as the reference standard, ROC curve analysis showed that the area under the curve was largest for CE+FSD MRA. The greatest sensitivity and specificity were obtained when a cut-off stenosis score of 2 was used. In patients with severe PAD,3 T FSD-MRA provides good-quality diagnostic images without a contrast agent and is a good supplement for CE-MRA. CE+FSD MRA can improve the accuracy of vascular stenosis diagnosis.

  11. Postoperative lumbar MR imaging with contrast enhancement. Comparison between symptomatic and asymptomatic patients

    Energy Technology Data Exchange (ETDEWEB)

    Grane, P. [Dept. of Neuroradiology, Karolinska Hospital, Stockholm (Sweden); Tullberg, T. [Dept. of Orthopaedics, St. Goeran`s Hospital, Stockholm (Sweden); Rydberg, J. [Dept. of Radiology, St. Goeran`s Hospital, Stockholm (Sweden); Lindgren, L. [Dept. of Neurosurgery, Karolinska Hospital, Stockholm (Sweden)

    1995-05-01

    Contrast-enhanced MR imaging of the spine after surgery for lumbar disk herniation almost always shows pathologic changes. To investigate to what extent these changes are correlated to patients` actual clinical symptoms, we compared the postoperative MR findings in 19 asymptomatic patients with 42 symptomatic patients (43 levels). The asymptomatic patients underwent MR examination one year after surgery. Twenty-six of the symptomatic patients underwent MR one year of less after surgery, and in 16 patients (17 levels) MR was performed more than one year after surgery. Sixteen percent of the asymptomatic and 42% of the symptomatic patients had disk herniation at the level of previous surgery. Most of the herniated disks were found in the symptomatic patients less than one year after surgery. The amount of epidural scar tissue, displacement and thickening of nerve roots, and compression of the dural sac were also studied. Disk herniation as a probable cause of recurrent sciatica was a common finding among symptomatic patients examined one year or less after surgery. In comparing asymptomatic patients and symptomatic patients with more than one year between surgery and MR examination, no significant radiologic differences, including disk herniation, were found. (orig.).

  12. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    Directory of Open Access Journals (Sweden)

    Nicolas D. Prionas, MD, PhD

    2015-01-01

    Full Text Available Dedicated breast computed tomography (bCT generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obtained after diagnosis. Lesion enhancement at contrast-enhanced breast CT matched previously published enhancement values of breast cancer. Contrast-enhanced dedicated bCT provided high-resolution tomographic images and physiologic contrast enhancement data that facilitated the detection of an early breast cancer.

  13. Quantitative perfusion analysis of the pancreas and duodenum in healthy dogs by use of contrast-enhanced ultrasonography.

    Science.gov (United States)

    Johnson-Neitman, Jennifer L; O'Brien, Robert T; Wallace, Johna D

    2012-03-01

    To investigate contrast-enhanced ultrasonography as a minimally invasive method for the subjective and quantitative assessment of pancreatic and duodenal perfusion in healthy adult dogs, with reference to perfusion in adjacent liver tissue. 8 clinically normal adult dogs. Contrast-enhanced ultrasonograms of the right pancreatic limb, proximal portion of the descending duodenum, and adjacent liver were acquired after i.v. administration of a microbubble contrast medium. Following subjective evaluation, quantitative time-intensity curves were generated from regions of interest in the pancreas, duodenum, and liver. Five contrast medium characteristics representing perfusion parameters were determined for each organ and used for statistical analysis: interval to arrival, inflow rate, peak intensity (PI), time of peak intensity (TPI), and outflow rate. Significant associations between pancreatic and duodenal values were found for interval to contrast medium arrival, PI, TPI, and outflow rate. Pancreatic and duodenal inflow rates were not correlated. Inflow and outflow rates were significantly faster and TPI significantly shorter for the pancreas and duodenum, compared with values for the liver. There was no significant difference among all 3 organs for interval to arrival and PI of contrast medium. Subjective evaluation findings corresponded to quantitative analysis results. Results suggested that contrast-enhanced ultrasonography may be a useful, minimally invasive method for evaluating pancreatic and duodenal perfusion in dogs. The data from healthy dogs reported here could aid in the assessment of pancreatic and duodenal conditions and their response to medical treatment.

  14. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    OpenAIRE

    Prionas, Nicolas D.; Aminololama-Shakeri, Shadi; Yang, Kai; Martinez, Steve R.; Lindfors, Karen K.; Boone, John M.

    2015-01-01

    Dedicated breast computed tomography (bCT) generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obta...

  15. Non-contrast enhanced navigator-gated balanced steady state free precession magnetic resonance angiography as a preferred magnetic resonance technique for assessment of the thoracic aorta.

    Science.gov (United States)

    van Kesteren, F; Elattar, M A; van Lienden, K P; Baan, J; Marquering, H A; Planken, R N

    2017-08-01

    To compare the objective and subjective image quality of non-contrast three-dimensional (3D) navigator-gated balanced steady state free precession magnetic resonance angiography (NC-MRA) and contrast-enhanced magnetic resonance angiography (CE-MRA) along the entire thoracic aorta. Fifty consecutive patients with thoracic aortic disease underwent NC-MRA and CE-MRA using a 1.5 T MRI system. Vessel sharpness was assessed using signal intensity profiles at five predefined levels of the thoracic aorta. Two readers scored subjective quality. Manual diameter measurements of both readers were used for calculation of interobserver variation. NC-MRA resulted in significantly sharper delineation of the aortic root, ascending aorta, and distal descending aorta compared to CE-MRA. Sharpness was comparable at the level of the arch and proximal descending aorta. NC-MRA resulted in significantly better subjective image quality. Interobserver agreement for diameter measurements was excellent for both techniques. NC-MRA resulted in superior image quality for assessment of the thoracic aorta and in better vessel sharpness for assessment of the aortic root and ascending aorta, when compared to CE-MRA. NC-MRA can be considered the MRA technique of choice for the assessment of the thoracic aorta diameters in clinical practice. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  16. Unenhanced respiratory-navigated NATIVE® TrueFISP magnetic resonance angiography in the evaluation of renal arteries: Comparison with contrast-enhanced magnetic resonance angiography.

    Science.gov (United States)

    Değirmenci, B; Kara, M; Kıdır, V; İnal, S; Sezer, T; Umul, A; Orhan, H; Çelik, A O; Demirtaş, H; Yilmaz, Ö

    2017-02-01

    To compare unenhanced three-dimensional (3D) NATIVE® true fast imaging with steady-state precession (TrueFISP) magnetic resonance (MR) angiography with the more conventional MR angiography technique obtained after intravenous administration of a gadolinium chelate in the evaluation of renal arteries and their branches in patients with suspected renal artery stenosis. A total of 39 patients (25 men, 14 women) with a mean age of 51.4±17.5years (SD) (range: 10-82years) were included in the study. All patients with suspected renal artery stenosis underwent unenhanced 3D NATIVE® TrueFISP MR angiography and contrast-enhanced MR angiography. The two MR angiography methods were compared by two independent readers for image quality using a four-point scale, diagnostic performance and grading of renal artery stenosis on a total of 78 renal arteries. For both readers image quality of unenhanced 3D NATIVE® TrueFISP MR angiography (3.12 to 3.63) was greater than that of contrast-enhanced MR angiography (1.94 to 2.71) for renal artery ostium-trunk and the left renal artery segmental branches. The sensitivity of 3D NATIVE® TrueFISP MR angiography for the diagnosis of renal artery stenosis was 100% for both readers for the right renal artery and 66% and 80% for the left renal artery for reader 1 and reader 2, respectively. Agreement between 3D NATIVE® TrueFISP MR angiography and CE-MR angiography was 95% (74/78) for reader 1 and 92% (72/78) for reader 2. Unenhanced NATIVE® TrueFISP magnetic resonance angiography can play an additional role in the evaluation of renal arteries in patients with hypertension, especially in subjects at risk of nephrogenic systemic fibrosis. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  17. Bile duct evaluation of potential living liver donors with Gd-EOB-DTPA enhanced MR cholangiography: Single-dose, double dose or half-dose contrast enhanced imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kinner, Sonja, E-mail: Sonja.Kinner@uni-due.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Steinweg, Verena [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Maderwald, Stefan [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany); Radtke, Arnold; Sotiropoulos, Georgios [Department of General Surgery, University Hospital Essen (Germany); Forsting, Michael; Schroeder, Tobias [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen (Germany)

    2014-05-15

    Introduction: Detailed knowledge of the biliary anatomy is essential to avoid complications in living donor liver transplantation. The aim of this study was to determine the optimal dosage of Gd-EOB-DTPA for contrast-enhanced magnetic resonance cholangiography (ce-MRC) with reference to contrast-enhanced CT cholangiography (ce-CTC). Materials and methods: 30 potential living liver donors (PLLD) underwent both ce-CTC and ce-MRC. Ten candidates each received single, double or half-dose Gd-EOB-DTPA. Ce-MRC images with and without inversion recovery pulses (T1w ± IR) were acquired 20–30 min after intravenous contrast injection. Image data was quantitatively and qualitatively reviewed by two radiologists based on a on a 5-point scale. Data sets were compared using a Mann–Whitney-U-test or Wilcoxon-rank-sum-test. Kappa values were also calculated. Results: All image series provided sufficient diagnostic information both showing normal biliary anatomy and variant bile ducts. Ce-CTC showed statistically significant better results compared to all ce-MRC data sets. T1w MRC with single dose Gd-EOB-DTPA proved to be superior to half and double dose in subjective and objective evaluation without a statistically significant difference. Conclusions: Ce-MRC is at any dosage inferior to ce-CTC. As far as preoperative planning of bile duct surgery is focused on the central biliary anatomy, ce-MRC can replace harmful ce-CTC strategies, anyway. Best results were seen with single dose GD-EOB-DTPA on T1w MRC+IR.

  18. Bile duct evaluation of potential living liver donors with Gd-EOB-DTPA enhanced MR cholangiography: Single-dose, double dose or half-dose contrast enhanced imaging.

    Science.gov (United States)

    Kinner, Sonja; Steinweg, Verena; Maderwald, Stefan; Radtke, Arnold; Sotiropoulos, Georgios; Forsting, Michael; Schroeder, Tobias

    2014-05-01

    Detailed knowledge of the biliary anatomy is essential to avoid complications in living donor liver transplantation. The aim of this study was to determine the optimal dosage of Gd-EOB-DTPA for contrast-enhanced magnetic resonance cholangiography (ce-MRC) with reference to contrast-enhanced CT cholangiography (ce-CTC). 30 potential living liver donors (PLLD) underwent both ce-CTC and ce-MRC. Ten candidates each received single, double or half-dose Gd-EOB-DTPA. Ce-MRC images with and without inversion recovery pulses (T1w±IR) were acquired 20-30min after intravenous contrast injection. Image data was quantitatively and qualitatively reviewed by two radiologists based on a on a 5-point scale. Data sets were compared using a Mann-Whitney-U-test or Wilcoxon-rank-sum-test. Kappa values were also calculated. All image series provided sufficient diagnostic information both showing normal biliary anatomy and variant bile ducts. Ce-CTC showed statistically significant better results compared to all ce-MRC data sets. T1w MRC with single dose Gd-EOB-DTPA proved to be superior to half and double dose in subjective and objective evaluation without a statistically significant difference. Ce-MRC is at any dosage inferior to ce-CTC. As far as preoperative planning of bile duct surgery is focused on the central biliary anatomy, ce-MRC can replace harmful ce-CTC strategies, anyway. Best results were seen with single dose GD-EOB-DTPA on T1w MRC+IR. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. T1-Weighted Contrast-Enhanced Magnetic Resonance Imaging of the Small Bowel: Comparison Between 1.5 and 7 T.

    Science.gov (United States)

    Hahnemann, Maria L; Kraff, Oliver; Orzada, Stephan; Umutlu, Lale; Kinner, Sonja; Ladd, Mark E; Quick, Harald H; Lauenstein, Thomas C

    2015-08-01

    T1-weighted (T1w) contrast-enhanced magnetic resonance imaging (MRI) of the small bowel at 1.5 T magnetic field strength has become a standard technique in investigating diseases of the small bowel. High-field MRI potentially offers improved soft tissue contrast and spatial resolution, providing increased image detail. The purpose of this study was to evaluate the feasibility of contrast-enhanced small bowel MRI at 7 T and to compare results with 1.5 T. Twelve healthy volunteers underwent small bowel MRI on a 1.5 T and 7 T MRI system. A coronal fat-saturated T1w spoiled gradient-echo sequence (3-dimensional [3D] FLASH) was applied precontrast and at 20 seconds, 75 seconds, and 120 seconds after intravenous contrast administration. Furthermore, late-phase coronal and axial fat-saturated T1w 2-dimensional (2D) FLASH data sets were acquired. Visual evaluation of tissue contrast and image detail of the small bowel wall and mesentery as well as contrast ratios were compared between 1.5 T and 7 T in an intraindividual comparison. In addition, subjective ratings of image impairment by artifacts were assessed at both field strengths. Magnetic resonance imaging of the small bowel at 7 T revealed equal tissue contrast and image detail compared with 1.5 T. Higher contrast and improved image detail of mesentery structures at 7 T were found in nonenhanced 3D FLASH. Quantitatively measured contrast between the bowel wall and bowel lumen showed significantly lower contrast at 7 T in nonenhanced 3D FLASH and in late-phase 2D FLASH. Image quality was more impaired at 7 T compared with 1.5 T, mainly due to increased susceptibility artifacts and B1 inhomogeneities. T1-weighted contrast-enhanced MRI of the small bowel at 7 T represents a promising MR technique for establishing ultra-high magnetic field strengths in clinical applications. Despite increased artifacts at 7 T, depiction of the small bowel was achieved with comparable quality to the current state-of-the-art field strength

  20. Fusion imaging of contrast-enhanced ultrasound and contrast-enhanced CT or MRI before radiofrequency ablation for liver cancers.

    Science.gov (United States)

    Bo, Xiao-Wan; Xu, Hui-Xiong; Wang, Dan; Guo, Le-Hang; Sun, Li-Ping; Li, Xiao-Long; Zhao, Chong-Ke; He, Ya-Ping; Liu, Bo-Ji; Li, Dan-Dan; Zhang, Kun

    2016-11-01

    To investigate the usefulness of fusion imaging of contrast-enhanced ultrasound (CEUS) and CECT/CEMRI before percutaneous ultrasound-guided radiofrequency ablation (RFA) for liver cancers. 45 consecutive patients with 70 liver lesions were included between March 2013 and October 2015, and all the lesions were identified on CEMRI/CECT prior to inclusion in the study. Planning ultrasound for percutaneous RFA was performed using conventional ultrasound, ultrasound-CECT/CEMRI and CEUS and CECT/CEMRI fusion imaging during the same session. The numbers of the conspicuous lesions on ultrasound and fusion imaging were recorded. RFA was performed according to the results of fusion imaging. Complete response (CR) rate was calculated and the complications were recorded. On conventional ultrasound, 25 (35.7%) of the 70 lesions were conspicuous, whereas 45 (64.3%) were inconspicuous. Ultrasound-CECT/CEMRI fusion imaging detected additional 24 lesions thus increased the number of the conspicuous lesions to 49 (70.0%) (70.0% vs 35.7%; p ultrasound). With the use of CEUS and CECT/CEMRI fusion imaging, the number of the conspicuous lesions further increased to 67 (95.7%, 67/70) (95.7% vs 70.0%, 95.7% vs 35.7%; both p ultrasound and ultrasound-CECT/CEMRI fusion imaging, respectively). With the assistance of CEUS and CECT/CEMRI fusion imaging, the confidence level of the operator for performing RFA improved significantly with regard to visualization of the target lesions (p = 0.001). The CR rate for RFA was 97.0% (64/66) in accordance to the CECT/CEMRI results 1 month later. No procedure-related deaths and major complications occurred during and after RFA. Fusion of CEUS and CECT/CEMRI improves the visualization of those inconspicuous lesions on conventional ultrasound. It also facilitates improvement in the RFA operators' confidence and CR of RFA. Advances in knowledge: CEUS and CECT/CEMRI fusion imaging is better than both conventional ultrasound and ultrasound

  1. Dynamic contrast-enhanced breast MRI at 7 Tesla utilizing a single-loop coil: a feasibility trial.

    Science.gov (United States)

    Umutlu, Lale; Maderwald, Stefan; Kraff, Oliver; Theysohn, Jens M; Kuemmel, Sherko; Hauth, Elke A; Forsting, Michael; Antoch, Gerald; Ladd, Mark E; Quick, Harald H; Lauenstein, Thomas C

    2010-08-01

    The aim of this study was to assess the feasibility of dynamic contrast-enhanced ultra-high-field breast imaging at 7 Tesla. A total of 15 subjects, including 5 patients with histologically proven breast cancer, were examined on a 7 Tesla whole-body magnetic resonance imaging system using a unilateral linearly polarized single-loop coil. Subjects were placed in prone position on a biopsy support system, with the coil placed directly below the region of interest. The examination protocol included the following sequences: 1) T2-weighted turbo spin echo sequence; 2) six dynamic T1-weighted spoiled gradient-echo sequences; and 3) subtraction imaging. Contrast-enhanced T1-weighted imaging at 7 Tesla could be obtained at high spatial resolution with short acquisition times, providing good image accuracy and a conclusively good delineation of small anatomical and pathological structures. T2-weighted imaging could be obtained with high spatial resolution at adequate acquisition times. Because of coil limitations, four high-field magnetic resonance examinations showed decreased diagnostic value. This first scientific approach of dynamic contrast-enhanced breast magnetic resonance imaging at 7 Tesla demonstrates the complexity of ultra-high-field breast magnetic resonance imaging and countenances the implementation of further advanced bilateral coil concepts to circumvent current limitations from the coil and ultra-high-field magnetic strength. 2010 AUR. Published by Elsevier Inc. All rights reserved.

  2. Contrast-enhanced flair imaging in the evaluation of infectious leptomeningeal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Parmar, Hemant [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore) and Department of Diagnostic Imaging, Hospital for Sick Children, Toronto (Canada)]. E-mail: parurad@hotmail.com; Sitoh, Y.-Y. [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Anand, Pooja [Department of Neurology, National Neuroscience Institute, 11 Jalan Tan Tock Seng (Singapore); Chua, Violet [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore); Hui, Francis [Department of Neuroradiology, National Neuroscience Institute, 11 Jalan Tan Tock Seng, Singapore 308433 (Singapore)

    2006-04-15

    Purpose: The purpose of our study was to compare contrast-enhanced fluid-attenuated inversion recovery (FLAIR) images with contrast-enhanced T1 weighted images for infectious leptomeningitis. Materials and methods: We studied twenty-four patients with a clinical suspicion of infectious meningitis with unenhanced FLAIR, contrast-enhanced T1 weighted and contrast-enhanced FLAIR MR sequences. Twelve patients had cytologic and biochemical diagnosis of meningitis on cerebrospinal fluid (CSF) examination obtained 48 h before or after the MR study. Sequences were considered positive if abnormal signal was seen in the subarachnoid space (cistern or sulci) or along pial surface. Results: Twenty-seven examinations in 24 patients were performed. Of the 12 patients (thirteen studies) in whom cytology was positive, unenhanced FLAIR images were positive in six cases (sensitivity 46%), contrast-enhanced FLAIR images were positive in 11 (sensitivity 85%), and contrast-enhanced T1 weighted MR images were positive in 11 patients (sensitivity 85%). Of the 12 patients (14 studies) in whom cerebrospinal fluid study was negative, unenhanced FLAIR images were negative in 13, contrast-enhanced FLAIR images were negative in 11, and contrast-enhanced T1 weighted MR images were negative in eight. Thus, the specificity of unenhanced FLAIR, contrast-enhanced FLAIR and contrast-enhanced T1 weighted images was 93, 79 and 57%, respectively. Conclusion: Our results suggest that post-contrast FLAIR images have similar sensitivity but a higher specificity compared to contrast-enhanced T1 weighted images for detection of leptomeningeal enhancement. It can be a useful adjunct to post-contrast T1 weighted images in evaluation of infectious leptomeningitis.

  3. Human cerebral blood volume measurements using dynamic contrast enhancement in comparison to dynamic susceptibility contrast MRI

    Energy Technology Data Exchange (ETDEWEB)

    Artzi, Moran [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Liberman, Gilad; Vitinshtein, Faina; Aizenstein, Orna [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Nadav, Guy [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Faculty of Engineering, Tel Aviv (Israel); Blumenthal, Deborah T.; Bokstein, Felix [Tel Aviv Sourasky Medical Center, Neuro-Oncology Service, Tel Aviv (Israel); Bashat, Dafna Ben [Tel Aviv Sourasky Medical Center, Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv (Israel); Tel Aviv University, Sackler Faculty of Medicine and Sagol School of Neuroscience, Tel Aviv (Israel)

    2015-07-15

    Cerebral blood volume (CBV) is an important parameter for the assessment of brain tumors, usually obtained using dynamic susceptibility contrast (DSC) MRI. However, this method often suffers from low spatial resolution and high sensitivity to susceptibility artifacts and usually does not take into account the effect of tissue permeability. The plasma volume (v{sub p}) can also be extracted from dynamic contrast enhancement (DCE) MRI. The aim of this study was to investigate whether DCE can be used for the measurement of cerebral blood volume in place of DSC for the assessment of patients with brain tumors. Twenty-eight subjects (17 healthy subjects and 11 patients with glioblastoma) were scanned using DCE and DSC. v{sub p} and CBV values were measured and compared in different brain components in healthy subjects and in the tumor area in patients. Significant high correlations were detected between v{sub p} and CBV in healthy subjects in the different brain components; white matter, gray matter, and arteries, correlating with the known increased tissue vascularity, and within the tumor area in patients. This work proposes the use of DCE as an alternative method to DSC for the assessment of blood volume, given the advantages of its higher spatial resolution, its lower sensitivity to susceptibility artifacts, and its ability to provide additional information regarding tissue permeability. (orig.)

  4. Contrast-enhanced ultrasound in liver transplant: first results and potential for complications in the postoperative period.

    Science.gov (United States)

    Clevert, D-A; Stickel, M; Minaifar, N; Löhe, F; Graeb, C; Jauch, K W; Reiser, M

    2009-01-01

    This study compared the efficacy of contrast-enhanced ultrasound (CEUS) using a second generation contrast medium versus CT or MRA in the assessment of vascular and biliary complications in postoperative follow-up of liver transplantation. The study group consisted of 36 consecutive liver transplant recipients who underwent post-transplantation CEUS examination after developing ascites and/or unclear liver function tests. Real time CEUS was performed after a bolus injection of SonoVue (1.6-2.4 ml, Bracco, Imaging Germany) followed by 10 ml of saline solution. Using contrast harmonic imaging (CHI) technique (Logiq 9, GE) with a 2.5-4-MHz transducer, a low mechanical index was chosen to avoid early destruction of the microbubbles (MI 0.1-0.2). In order to confirm the results, the patients underwent contrast-enhanced MRI or CT. Complications were identified in 16 of 36 patients (44.4%). Five transplants (14%) had hepatic artery thrombosis (n=2) or significant stenosis (n=3). Six transplants (16%) developed portal vein stenosis (n=4) or portal vein thrombosis (n=2). MRI or CT confirmed the findings of the CEUS in all 11 cases. Biliary stricture at the anastomotic site was detected in 5 patients. MR-CP confirmed the findings of all strictures. Due to advances in contrast-enhanced US, vascular and biliary complications in the postoperative period following liver transplantation can be reliably diagnosed non-invasively on the intensive care unit. CEUS shows vascular as well as biliary complications in the postoperative patient with a high degree of accuracy.

  5. Pulmonary Arterial Hypertension: Use of Delayed Contrast-Enhanced Cardiovascular Magnetic Resonance in Risk Assessment

    Science.gov (United States)

    Bessa, Luiz Gustavo Pignataro; Junqueira, Flávia Pegado; Bandeira, Marcelo Luiz da Silva; Garcia, Marcelo Iorio; Xavier, Sérgio Salles; Lavall, Guilherme; Torres, Diego; Waetge, Daniel

    2013-01-01

    Background Pulmonary arterial hypertension is a severe and progressive disease. Its early diagnosis is the greatest clinical challenge. Objective To evaluate the presence and extension of the delayed myocardial contrast-enhanced cardiovascular magnetic resonance, as well as to verify if the percentage of the myocardial fibrosis mass is a severity predictor. Methods Cross-sectional study with 30 patients with pulmonary arterial hypertension of groups I and IV, subjected to clinical, functional and hemodynamic evaluation, and to cardiac magnetic resonance. Results The mean age of patients was 52 years old, with female predominance (77%). Among the patients, 53% had right ventricular failure at diagnosis, and 90% were in functional class II/III. The mean of the 6-minute walk test was 395m. In hemodynamic study with right catheterism, the mean average pulmonary arterial pressure was 53.3mmHg, of the cardiac index of 2.1L/ min.m2, and median right atrial pressure was 13.5 mmHg. Delayed myocardial contrast enhanced cardiovascular magnetic resonance was found in 28 patients. The mean fibrosis mass was 9.9 g and the median percentage of fibrosis mass was 6.17%. The presence of functional class IV, right ventricular failure at diagnosis, 6-minute walk test < 300 meters and right atrial pressure ≥ 15 mmHg, with cardiac index < 2.0 L/ min.m2, there was a relevant association with the increased percentage of myocardial fibrosis. Conclusion The percentage of the myocardial fibrosis mass indicates a non-invasive marker with promising perspectives in identifying patients with high risk factors for pulmonary hypertension. PMID:23979779

  6. Pulmonary Arterial Hypertension: Use of Delayed Contrast-Enhanced Cardiovascular Magnetic Resonance in Risk Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Bessa, Luiz Gustavo Pignataro, E-mail: lgpignataro@ig.com.br; Junqueira, Flávia Pegado; Bandeira, Marcelo Luiz da Silva; Garcia, Marcelo Iorio; Xavier, Sérgio Salles; Lavall, Guilherme; Torres, Diego; Waetge, Daniel [Hospital Universitário Clementino Fraga Filho, Ilha do Fundão, RJ (Brazil)

    2013-10-15

    Pulmonary arterial hypertension is a severe and progressive disease. Its early diagnosis is the greatest clinical challenge. To evaluate the presence and extension of the delayed myocardial contrast-enhanced cardiovascular magnetic resonance, as well as to verify if the percentage of the myocardial fibrosis mass is a severity predictor. Cross-sectional study with 30 patients with pulmonary arterial hypertension of groups I and IV, subjected to clinical, functional and hemodynamic evaluation, and to cardiac magnetic resonance. The mean age of patients was 52 years old, with female predominance (77%). Among the patients, 53% had right ventricular failure at diagnosis, and 90% were in functional class II/III. The mean of the 6-minute walk test was 395m. In hemodynamic study with right catheterism, the mean average pulmonary arterial pressure was 53.3mmHg, of the cardiac index of 2.1L/ min.m{sup 2}, and median right atrial pressure was 13.5 mmHg. Delayed myocardial contrast enhanced cardiovascular magnetic resonance was found in 28 patients. The mean fibrosis mass was 9.9 g and the median percentage of fibrosis mass was 6.17%. The presence of functional class IV, right ventricular failure at diagnosis, 6-minute walk test < 300 meters and right atrial pressure ≥ 15 mmHg, with cardiac index < 2.0 L/ min.m{sup 2}, there was a relevant association with the increased percentage of myocardial fibrosis. The percentage of the myocardial fibrosis mass indicates a non-invasive marker with promising perspectives in identifying patients with high risk factors for pulmonary hypertension.

  7. "One-Stop Shop": Free-Breathing Dynamic Contrast-Enhanced Magnetic Resonance Imaging of the Kidney Using Iterative Reconstruction and Continuous Golden-Angle Radial Sampling.

    Science.gov (United States)

    Riffel, Philipp; Zoellner, Frank G; Budjan, Johannes; Grimm, Robert; Block, Tobias K; Schoenberg, Stefan O; Hausmann, Daniel

    2016-11-01

    The purpose of the present study was to evaluate a recently introduced technique for free-breathing dynamic contrast-enhanced renal magnetic resonance imaging (MRI) applying a combination of radial k-space sampling, parallel imaging, and compressed sensing. The technique allows retrospective reconstruction of 2 motion-suppressed sets of images from the same acquisition: one with lower temporal resolution but improved image quality for subjective image analysis, and one with high temporal resolution for quantitative perfusion analysis. In this study, 25 patients underwent a kidney examination, including a prototypical fat-suppressed, golden-angle radial stack-of-stars T1-weighted 3-dimensional spoiled gradient-echo examination (GRASP) performed after contrast agent administration during free breathing. Images were reconstructed at temporal resolutions of 55 spokes per frame (6.2 seconds) and 13 spokes per frame (1.5 seconds). The GRASP images were evaluated by 2 blinded radiologists. First, the reconstructions with low temporal resolution underwent subjective image analysis: the radiologists assessed the best arterial phase and the best renal phase and rated image quality score for each patient on a 5-point Likert-type scale.In addition, the diagnostic confidence was rated according to a 3-point Likert-type scale. Similarly, respiratory motion artifacts and streak artifacts were rated according to a 3-point Likert-type scale.Then, the reconstructions with high temporal resolution were analyzed with a voxel-by-voxel deconvolution approach to determine the renal plasma flow, and the results were compared with values reported in previous literature. Reader 1 and reader 2 rated the overall image quality score for the best arterial phase and the best renal phase with a median image quality score of 4 (good image quality) for both phases, respectively. A high diagnostic confidence (median score of 3) was observed. There were no respiratory motion artifacts in any of the

  8. Contrast-enhanced ultrasound in non-operative management of pancreatic injury in childhood

    Energy Technology Data Exchange (ETDEWEB)

    Valentino, Massimo; Sartoni Galloni, Stefania; Rimondi, Maria Rita; Barozzi, Libero [University Hospital S. Orsola-Malpighi, Emergency Department, Bologna (Italy); Gentili, Andrea [University Hospital S. Orsola-Malpighi, Department of Anaesthesia and Intensive Care, Bologna (Italy); Lima, Mario [University Hospital S. Orsola-Malpighi, Department of Paediatrics, Bologna (Italy)

    2006-06-15

    We report a 5-year-old child with pancreatic trauma from a blunt abdominal injury that was monitored with contrast-enhanced sonography. Unenhanced US failed to demonstrate the abnormality that was recognized by CT and MRI. The injury was well demonstrated by contrast-enhanced US which was therefore used for follow-up until its healing. (orig.)

  9. Contrast-enhanced power Doppler ultrasonography of the metacarpophalangeal joints in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, Michel; Strandberg, Charlotte

    2003-01-01

    The aim of this study was to examine, with dynamic contrast-enhanced MRI as the reference, if contrast-enhanced power Doppler ultrasonography (CE PDUS) of rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints provides additional information for evaluation of synovial inflammation compared...

  10. Study of the renal segmental arterial anatomy with contrast-enhanced multi-detector computed tomography.

    Science.gov (United States)

    Rocco, Francesco; Cozzi, Luigi Alberto; Cozzi, Gabriele

    2015-07-01

    To use triphasic multi-detector computed tomography (MDCT) to study the renal segmental arterial anatomy and its relationship with the urinary tract to plan nephron-sparing surgery (NSS). One hundred and fifty nine patients underwent abdominal contrast-enhanced MDCT. We evaluated renal arteries and parenchymal vasculature. In 61 patients, the arteries and the urinary tract were represented simultaneously. 86.60% presented a single renal artery; 13.4%, multiple arteries. All single renal arteries divided into anterior and posterior branch before the hilum. The anterior artery branched into a superior, middle, and inferior branch. In 43.14%, the inferior artery arose before the others; in 45.75%, the superior artery arose before the others; in 9.80%, the branches shared a common trunk. In 26.80%, the posterior artery supplies the entire posterior surface; in 73.20%, it ends along the inferior calyx. In 96.73%, the upper pole was vascularized by the anterior superior branch and the posterior artery: the "tuning fork". MDCT showed four vascular segments in 96.73% and five in 3.27%. MDCT showed two avascular areas: the first along the projection of the inferior calyx on the posterior aspect, the second between the branches of the "tuning fork". The arterial phase provides the arterial tree representation; the delayed phase shows arteries and urinary tract simultaneously. MDCT provides a useful representation of the renal anatomy prior to intervascular-intrarenal NSS.

  11. Isoattenuating insulinomas at biphasic contrast-enhanced CT: frequency, clinicopathologic features and perfusion characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Liang; Xue, Hua-dan; Sun, Hao; Wang, Xuan; He, Yong-lan; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)

    2016-10-15

    We aimed to determine the frequency of isoattenuating insulinomas, to investigate their clinicopathological features and to assess their regional pancreatic perfusion characteristics. Institutional review board approval was obtained, and patient informed consent was waived. From July 2010 to June 2014, 170 patients (66 male, 104 female) with endogenous hyperinsulinemic hypoglycemia underwent biphasic contrast-enhanced CT before surgery, and 129 of those patients also received preoperative whole-pancreas CT perfusion. A total of 181 tumours were proved histopathologically after surgery. Enhancement pattern and regional pancreatic perfusion characteristics were analyzed. Clinical features, tumour size and pathological grading were investigated. The frequency of isoattenuating tumours was 24.9 %. Tumour size and WHO grading was not significantly different between isoattenuating and hyperattenuating tumours. Tumour-free regions had identical blood flow (BF) regardless of their location (p = 0.35). Isoattenuating tumour-harbouring regions had lower BF compared with hyperattenuating tumour-harbouring regions; both showed higher BF compared with tumour-free neighbourhood regions (all p < 0.01). For patients with isoattenuating tumours, the overall hospital stay was longer (p < 0.01). A substantial subset of insulinomas were isoattenuating on biphasic CT. CT perfusion showed higher BF in tumour-harbouring regions compared to tumour-free regions, providing a clue for tumour regionalization. (orig.)

  12. Contrast-enhanced spectral mammography in patients referred from the breast cancer screening programme.

    Science.gov (United States)

    Lobbes, Marc B I; Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C; Nelemans, Patty J; van Roozendaal, Lori; Smidt, Marjolein L; Heuts, Esther; Wildberger, Joachim E

    2014-07-01

    Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0% (+3.1%), specificity to 87.7% (+45.7%), PPV to 76.2% (+36.5%) and NPV to 100.0% (+2.9%) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. • CESM is feasible in the workflow of referrals from routine breast screening. • CESM is superior to mammography, even in low disease prevalence populations. • CESM has an extremely high negative predictive value for breast cancer. • CESM is comparable to MRI in assessment of breast cancer extent. • CESM is comparable to histopathology in assessment of breast cancer extent.

  13. Contrast-enhanced spectral mammography in patients referred from the breast cancer screening programme

    Energy Technology Data Exchange (ETDEWEB)

    Lobbes, Marc B.I.; Wildberger, Joachim E. [Maastricht University Medical Center, Department of Radiology, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, Maastricht (Netherlands); Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C. [Maastricht University Medical Center, Department of Radiology, Maastricht (Netherlands); Nelemans, Patty J. [Maastricht University, Department of Epidemiology, Maastricht (Netherlands); Roozendaal, Lori van; Heuts, Esther [Maastricht University Medical Center, Department of Surgical Oncology, Maastricht (Netherlands); Smidt, Marjolein L. [Maastricht University Medical Center, Department of Surgical Oncology, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, Maastricht (Netherlands)

    2014-07-15

    Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0 % (+3.1 %), specificity to 87.7 % (+45.7 %), PPV to 76.2 % (+36.5 %) and NPV to 100.0 % (+2.9 %) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p < 0.0001). A similar trend was observed in the ROC curve. For conventional mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p < 0.0001). In addition, good agreement between tumour diameters measured using CESM, breast MRI and histopathology was observed. CESM increases diagnostic performance of conventional mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. (orig.)

  14. Accuracy of Contrast-Enhanced Ultrasound in the Diagnosis of Bile Duct Obstruction

    Science.gov (United States)

    Fontán, F. J. P.; Reboredo, Á. R.; Siso, A. R.

    2015-01-01

    Purpose: To investigate the ability of contrast-enhanced ultrasound (CEUS) to differentiate benign from malignant lesions causing biliary duct obstruction. Materials and Methods: Between November 2006 and December 2013, 59 patients with bile duct obstruction of undetermined cause in baseline ultrasound underwent CEUS study. The enhancement and posterior washout were analyzed in real time all along the study duration (5′). The final diagnosis suggested by CEUS was compared with histologic diagnosis (47.5%) or with radiologic follow-up with TC, RM or ERCP. Results: Final diagnoses included 42 malignant lesions (cholangiocarcinoma n=22, metastases n=6, pancreatic carcinoma n=6, hepatocarcinoma n=4, gallbladder carcinoma n=2, ampullary carcinoma n=1 and lymphoma n=1) and 17 benign lesions (lithiasis or biliary sludge n=15, xanthogranulomatous cholecystitis n=1 and indeterminate n=1). CEUS accuracy compared with final diagnoses based on combined reference standard was 86.4%. CEUS correctly identified 36 of 42 malignant lesions (sensibility 85.7%) and 15 of 17 benign lesions (specificity 88.2%). The positive predictive value of CEUS for malignancy was 94.7%, while the negative predictive value was 71.4%. Conclusion: CEUS is useful to differentiate between benign and malignant causes of obstructive jaundice. This technique improves the detection of bile duct invasion in hepatic neoplasms and permits better evaluation of intra- and extraductal extension of hilar hepatobiliary tumors. PMID:27689143

  15. Quantitative dynamic contrast-enhanced MR imaging analysis of complex adnexal masses: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Thomassin-Naggara, Isabelle [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Radiology, Paris (France); Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Service de Radiologie, Hopital Tenon, Paris (France); Balvay, Daniel [Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Aubert, Emilie; Bazot, Marc [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Radiology, Paris (France); Darai, Emile; Rouzier, Roman [Hopital Tenon, Assistance Publique-Hopitaux de Paris, Department of Gynaecology-Obstetrics, Paris (France); Cuenod, Charles A. [Laboratoire de recherche en imagerie - UMR 970 INSERM - Universite Rene Descartes, Paris (France); Hopital Europeen Georges Pompidou (HEGP), Department of Radiology, Paris (France)

    2012-04-15

    To evaluate the ability of quantitative dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) to differentiate malignant from benign adnexal tumours. Fifty-six women with 38 malignant and 18 benign tumours underwent MR imaging before surgery for complex adnexal masses. Microvascular parameters were extracted from high temporal resolution DCE-MRI series, using a pharmacokinetic model in the solid tissue of adnexal tumours. These parameters were tissue blood flow (F{sub T}), blood volume fraction (Vb), permeability-surface area product (PS), interstitial volume fraction (Ve), lag time (Dt) and area under the enhancing curve (rAUC). Area under the receiver operating curve (AUROC) was calculated as a descriptive tool to assess the overall discrimination of parameters. Malignant tumours displayed higher F{sub T}, Vb, rAUC and lower Ve than benign tumours (P < 0.0001, P = 0.0006, P = 0.04 and P = 0.0002, respectively). F{sub T} was the most relevant factor for discriminating malignant from benign tumours (AUROC = 0.86). Primary ovarian invasive tumours displayed higher F{sub T} and shorter Dt than borderline tumours. Malignant adnexal tumours with associated peritoneal carcinomatosis at surgery displayed a shorter Dt than those without peritoneal carcinomatosis at surgery (P = 0.01). Quantitative DCE-MRI is a feasible and accurate technique to differentiate malignant from benign adnexal tumours and could potentially help oncologists with management decisions. (orig.)

  16. Leptomeningeal contrast enhancement in moyamoya: its potential role in postoperative assessment of circulation through the bypass

    Energy Technology Data Exchange (ETDEWEB)

    Komiyama, M.; Nakajima, H.; Nishikawa, M.; Yasui, T. [Dept. of Neurosurgery, Osaka City General Hospital (Japan); Kitano, S.; Sakamoto, H. [Dept. of Paediatric Neurosurgery, Osaka City General Hospital (Japan)

    2001-01-01

    Leptomeningeal contrast enhancement (LMCE) is one of the MRI features of moyamoya. Its clinical significance, however, is not elucidated. Our purpose was to characterise LMCE on MRI and to evaluate its role in the assessment of circulation through a surgically established bypass in moyamoya. We studied 16 patients with idiopathic moyamoya (seven males, nine females, includingt four children, aged 7 to 54 years, mean 24 years) who underwent T1-weighted MRI before and after intravenous contrast medium. The presence of LMCE, its intensity and anatomical distribution, catheter angiographic findings, and relation of LMCE to the bypass surgery were assessed. More LMCE was seen in the cerebrum in most patients with moyamoya than in normal controls. LMCE in the brain stem and cerebellum was minimal, similar to that seen in the controls. LMCE was less prominent following surgery than before operation or in patients who did not undergo surgery. In three patients examined both before and after operation LMCE became less prominent following bypass surgery. As LMCE becomes less prominent after ''effective'' bypass surgery, this may be used for evaluation of effectiveness of surgery in moyamoya. (orig.)

  17. Contrast-enhanced MRI features in the early diagnosis of Juvenile Idiopathic Arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Hemke, Robert; Maas, Mario [University of Amsterdam, Department of Radiology Academic Medical Center, Amsterdam (Netherlands); Kuijpers, Taco W.; Schonenberg-Meinema, Dieneke [University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Nusman, Charlotte M. [University of Amsterdam, Department of Radiology Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Rossum, Marion A.J. van; Berg, J.M. van den [University of Amsterdam, Department of Pediatric Hematology, Immunology, Rheumatology and Infectious Disease, Emma Children' s Hospital AMC, Amsterdam (Netherlands); Department of Pediatric Rheumatology, Reade, Amsterdam (Netherlands); Dolman, Koert M. [Department of Pediatric Rheumatology, Reade, Amsterdam (Netherlands); St. Lucas Andreas Hospital, Department of Pediatrics, Amsterdam (Netherlands)

    2015-11-15

    To determine whether clinical, laboratory or Magnetic Resonance Imaging (MRI) measures differentiate Juvenile Idiopathic Arthritis (JIA) from other forms of active childhood arthritis. We prospectively collected data of 80 treatment-naive patients clinically suspected of JIA with active non-infectious arthritis of (at least) one knee for <12 months duration. Upon presentation patients underwent clinical and laboratory assessments and contrast-enhanced MRI. MRI was not used as a diagnostic criterion. Forty-four (55 %) patients were clinically diagnosed with JIA, whereas in 36 (45 %) patients the diagnosis of JIA was discarded on clinical or laboratory findings. MRI-based synovitis was present in 27 (61.4 %) JIA patients and in 7 (19.4 %) non-JIA patients (P < 0.001). Five factors (male gender, physician's global assessment of overall disease activity, joints with limited range of motion, HLA-B27, MRI-based synovitis) were associated with the onset of JIA. In multivariate analysis MRI-based synovitis proved to be independently associated with JIA (OR 6.58, 95 % CI 2.36-18.33). In patients with MRI-based synovitis, the RR of having JIA was 3.16 (95 % CI 1.6-6.4). The presence of MRI-based synovitis is associated with the clinical onset of JIA. Physical examination could be supported by MRI, particularly to contribute in the early differentiation of different forms of non-infectious childhood arthritis. (orig.)

  18. Identification of residual tumor with intraoperative contrast-enhanced ultrasound during glioblastoma resection.

    Science.gov (United States)

    Prada, Francesco; Bene, Massimiliano Del; Fornaro, Riccardo; Vetrano, Ignazio G; Martegani, Alberto; Aiani, Luca; Sconfienza, Luca Maria; Mauri, Giovanni; Solbiati, Luigi; Pollo, Bianca; DiMeco, Francesco

    2016-03-01

    The purpose of this study was to assess the capability of contrast-enhanced ultrasound (CEUS) to identify residual tumor mass during glioblastoma multiforme (GBM) surgery, to increase the extent of resection. The authors prospectively evaluated 10 patients who underwent surgery for GBM removal with navigated ultrasound guidance. Navigated B-mode and CEUS were performed prior to resection, during resection, and after complete tumor resection. Areas suspected for residual tumors on B-mode and CEUS studies were localized within the surgical field with navigated ultrasound and samples were sent separately for histopathological analysis to confirm tumor presence. In all cases tumor remnants were visualized as hyperechoic areas on B-mode, highlighted as CEUS-positive areas, and confirmed as tumoral areas on histopathological analysis. In 1 case only, CEUS partially failed to demonstrate residual tumor because the residual hyperechoic area was devascularized prior to ultrasound contrast agent injection. In all cases CEUS enhanced B-mode findings. As has already been shown in other neoplastic lesions in other organs, CEUS is extremely specific in the identification of residual tumor. The ability of CEUS to distinguish between tumor and artifacts or normal brain on B-mode is based on its capacity to show the vascularization degree and not the echogenicity of the tissues. Therefore, CEUS can play a decisive role in the process of maximizing GBM resection.

  19. Contrast-Enhanced Digital Mammography in the Surgical Management of Breast Cancer.

    Science.gov (United States)

    Ali-Mucheru, Mariam; Pockaj, Barbara; Patel, Bhavika; Pizzitola, Victor; Wasif, Nabil; Stucky, Chee-Chee; Gray, Richard

    2016-12-01

    Contrast-enhanced digital mammography (CEDM) is a new breast imaging technique. The role of CEDM in the surgical management of breast cancer has not yet been characterized. A retrospective review of prospective breast surgery and breast imaging databases for patients who underwent CEDM and had breast cancer surgery. A total of 351 patients had CEDM; 128 had malignant lesions, and 101 of these underwent surgery with 105 malignancies identified. The mean age was 62 years (range 25-85 years). The histology was 65 % invasive ductal carcinoma, 16 % invasive lobular carcinoma, 11 % ductal carcinoma-in situ, 3 % mixed invasive ductal carcinoma/invasive lobular carcinoma, and 5 % other histologies. After excluding two lesions that had been removed before the examination, CEDM identified 98 % (n = 101/103) of the index lesions. The two lesions not identified were Paget disease only and a parasternal lesion too medial to include in the field of view. CEDM led to additional biopsies in 12 % (n = 12) of patients. Of these, 67 % (n = 8) proved to be invasive carcinoma and 33 % (n = 4) were benign. CEDM changed surgical management in 20 % (n = 20) of cancer patients with a 4 % (n = 4) rate of conversion to mastectomy. Among patients undergoing surgical therapy for breast cancer, CEDM was highly sensitive, had size measurements that correlated well with histologic size, and produced a relatively low rate of false-positive additional biopsy findings. CEDM appears to be promising as an alternative to magnetic resonance imaging in the surgical planning of these patients.

  20. Diagnostic and prognostic values of contrast-enhanced ultrasound in breast cancer: a retrospective study

    Directory of Open Access Journals (Sweden)

    Zhao YX

    2017-02-01

    Full Text Available Yi-Xuan Zhao, Shuang Liu, Yan-Bing Hu, Yan-Yan Ge, Dong-Mei Lv Department of Ultrasound, Second Hospital, Jilin University, Changchun, People’s Republic of China Abstract: This study aimed to explore the diagnostic and prognostic values of contrast-enhanced ultrasound (CEUS in breast cancer. Between September 2009 and October 2011, a total of 143 breast cancer patients and 161 healthy people were selected as case group and control group, respectively. After the identification of lesions by conventional ultrasound, all patients underwent CEUS. The CEUS images were analyzed, and time–intensity curves (TICs were obtained. Hematoxylin–eosin and immunohistochemistry staining was performed on tissue specimens, according to which the expressions of estrogen receptor (ER, c-erb-B2, p53, and Ki-67 were measured. Multivariate logistic regression analysis was used to compare CEUS and TIC parameters between the two groups. Compared with the control group, cancer patients showed high enhancement, heterogeneous enhancement or defects in the central region, expansion of lesion diameter after enhancement and crab-like blur lesion edges. The peak intensity (PI, relative start time of enhancement, relative PI, and relative area under the curve in the case group were significantly higher than those in the control group. Logistic analysis showed that the uniformity of enhancement, expansion of lesion diameter, and relative PI were significant diagnostic parameters of breast cancer, with area under the curve being 0.798, 0.776, and 0.919, respectively. There were strong associations between CEUS characteristics and expressions of prognostic factors in breast cancer: the heterogeneous enhancement was common in c-erb-B2-positive tumors; the centripetal enhancement occurred more in ER-negative tumors; perforator vessels were often seen in tumors at high histological grade; perfusion defects were common in ER-negative, c-erb-B2-positive, and Ki-67-positive tumors

  1. Contrast-enhanced sonography for detection of secondary lymph nodes in a melanoma tumor animal model.

    Science.gov (United States)

    Liu, Ji-Bin; Merton, Daniel A; Berger, Adam C; Forsberg, Flemming; Witkiewicz, Agnieszka; Zhao, Hongjia; Eisenbrey, John R; Fox, Traci B; Goldberg, Barry B

    2014-06-01

    To investigate the use of contrast-enhanced ultrasound imaging (US) for detection of secondary lymph nodes (LNs) in a naturally occurring melanoma swine model compared to surgery and pathologic assessment. Twenty-seven Sinclair swine were studied. The perfluorobutane microbubble contrast agent Sonazoid (GE Healthcare, Oslo, Norway) was administered (1.0 mL total dose) around the melanoma, and contrast-enhanced US was used to localize contrast-enhanced sentinel lymph nodes (SLNs). Then Sonazoid (dose, 0.25-1.0 mL) was injected into the SLNs to detect contrast-enhanced efferent lymphatic channels and secondary LNs. After peritumoral injection of blue dye, a surgeon (blinded to the contrast-enhanced US results) performed a radical LN dissection. Contrast-enhanced US was used to guide removal of any enhanced secondary LNs left after radical LN dissection. Clustered conditional logistic regression analyzed the benefit of contrast-enhanced US-directed secondary LN dissection over radical LN dissection using pathologic findings as the reference standard. A total of 268 secondary LNs were resected, with 59 (22%) containing metastases. Contrast-enhanced US detected 92 secondary LNs; 248 were identified by radical LN dissection; and 68 were identified by both methods. Metastases were detected in 20% (51 of 248) and 40% (37 of 92) of the secondary LNs identified by radical LN dissection and contrast-enhanced US, respectively. Thus, secondary LNs detected by contrast-enhanced US were nearly 5 times more likely to contain metastases than secondary LNs removed by radical LN dissection (odds ratio, 4.8; P < .0001). Twenty-two of the 180 secondary LNs (12%) identified only by radical LN dissection contained metastases, whereas contrast-enhanced US identified 20 secondary LNs after the surgeon completed the radical LN dissection, of which 8 (40%) contained metastases. Secondary LNs can be detected by using contrast-enhanced US after injection of Sonazoid into SLNs. Secondary LNs

  2. P16.27DIFFERENTIATING BRAIN RADIONECROSIS FROM TUMOR RECURRENCE: A ROLE FOR CONTRAST ENHANCED ULTRASOUND (CEUS)? CASE REPORT

    Science.gov (United States)

    Mattei, L.; Prada, F.; Legnani, F.; Casali, C.; Filippini, A.; Perin, A.; Saini, M.; Saladino, A.; Vetrano, I.; DiMeco, F.

    2014-01-01

    BACKGROUND: Differentiating radionecrosis from local tumor recurrence is a major concern in the management of patients harbouring a cerebral tumor and treated with radiotherapy. In these cases, contrast-enhanced MRI usually shows ambiguous enhancement, while advanced imaging techniques (MRI spectroscopy, DWI, DTI, perfusion and PET) are still far from being validated as a reliable alternative to biopsy and histological assessment. CASE REPORT: We report the case of a patient who underwent cyberknife radiosurgery (21Gy) for a left rolandic brain metastasis from a lung carcinoma. Four months after radiotherapy, she started experiencing a progressive worsening of her upper right limb's strenght, with a neuroradiological evidence at serial MRIs of a progressive enhancing rolandic lesion. The patient underwent surgical removal of the lesion at our Neurosurgical Division: neurophysiological monitoring, standard B-mode UltraSonography and Contrast-Enhanced UltraSonography (CEUS) were performed intraoperatively to assist in tumor resection. Very interestingly, CEUS did not show any enhancement of the pathologic tissue, differently from what is expected for brain metastases, as reported in previous studies. Histopathological examination showed nervous tissue with post-treatment radiation effects (radionecrosis) with a few metastatic cells. DISCUSSION: Contrast-Enhanced UltraSound is progressively becoming a widespread tool in neurosurgery. Previous studies have described the contrastographic pattern of different cerebral lesions, including metastases. Surprisingly, despite a strong uptake of contrast agent at MRI, we observed that radionecrotic tissue did not show any enhancement at CEUS. For the first time we report the appearance of radionecrosis at CEUS; the lack of contrast enhancement could represent an important hallmark in differential diagnosis with neoplastic tissue. Moreover, in this report, the use of CEUS was confined to the intraoperative stage; however, new

  3. Low-dose, time-resolved, contrast-enhanced 3D MR angiography in cardiac and vascular diseases: correlation to high spatial resolution 3D contrast-enhanced MRA

    Energy Technology Data Exchange (ETDEWEB)

    Krishnam, M.S. [Department of Radiological Sciences, University of California at Los Angeles, Los Angeles, CA (United States)], E-mail: mkrishnam@mednet.ucla.edu; Tomasian, A.; Lohan, D.G.; Tran, L.; Finn, J.P.; Ruehm, S.G. [Department of Radiological Sciences, University of California at Los Angeles, Los Angeles, CA (United States)

    2008-07-15

    Aim: To evaluate the effectiveness of low-dose, contrast-enhanced, time-resolved, three-dimensional (3D) magnetic resonance (MR) angiography (TR-MRA) in the assessment of various cardiac and vascular diseases, and to compare the results with high-resolution contrast-enhanced MRA (CE-MRA). Materials and Methods: Thirty consecutive patients underwent contrast-enhanced 3D TR-MRA and high spatial resolution 3D CE-MRA for evaluation of cardiac and thoracic vascular diseases at 1.5 T, and neurovascular, abdominal and peripheral vascular diseases at 3 T. Gadolinium-based contrast medium was administered at a constant dose of 5 ml for TR-MRA, and 20 ml (lower extremity 30 ml) for CE-MRA. Two readers evaluated image quality using a four-point scale (from 0 = excellent to 3 = non-diagnostic), artefacts and findings on both datasets. Interobserver variability was tested with kappa coefficient. Results: The overall image quality for TR-MRA was in the diagnostic range (median 0, range 0-1; k = 0.74). Readers demonstrated important additional dynamic information on TR-MRA in 28 of 30 patients (k = 0.84). Confident evaluation of organ perfusion (n = 23), arteriovenous malformation/fistula flow patterns (n = 7), exclusion of intra-cardiac shunts (n = 6), and assessment of stent and conduit patency (n = 5) were performed by both readers using TR-MRA. Readers demonstrated fine vascular details with higher confidence in 10 patients on CE-MRA. Using CE-MRA, Reader 1 and 2 depicted anatomical details in 6 and 5 patients, respectively, only on CE-MRA. Conclusion: Low-dose TR-MRA yields rapid and important functional and anatomical information in patients with cardiac and vascular diseases. Due to limited spatial resolution, TR-MRA is inferior to CE-MRA in demonstrating fine vascular details.

  4. Value of fusion of PET and MRI for staging of endometrial cancer: Comparison with {sup 18}F-FDG contrast-enhanced PET/CT and dynamic contrast-enhanced pelvic MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro, E-mail: kitajima@med.kobe-u.ac.jp [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Suenaga, Yuko; Ueno, Yoshiko [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Kanda, Tomonori [Department of Obsterics and Gynecology of Kobe University School of Medicine, Kobe (Japan); Department of Radiology, Hyogo Cancer Center, Hyogo (Japan); Maeda, Tetsuo; Takahashi, Satoru [Department of Radiology, Kobe University School of Medicine, Kobe (Japan); Ebina, Yasuhiko; Miyahara, Yoshiya; Yamada, Hideto [Department of Obsterics and Gynecology of Kobe University School of Medicine, Kobe (Japan); Department of Radiology, Hyogo Cancer Center, Hyogo (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University School of Medicine, Kobe (Japan)

    2013-10-01

    Purpose: To investigate the diagnostic value of retrospective fusion of pelvic MRI and {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) PET images for assessment of locoregional extension and nodal staging of endometrial cancer. Materials and methods: Thirty patients with biopsy-proven endometrial cancer underwent preoperative contrast-enhanced PET/CT (PET/ceCT) and pelvic dynamic contrast-enhanced MRI for initial staging. Diagnostic performance of PET/ceCT, contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) for assessing the extent of the primary tumor (T stage) and metastasis to regional LNs (N stage) was evaluated by two experienced readers. Histopathological and follow-up imaging results were used as the gold standard. The McNemar test was employed for statistical analysis. Results: Fused PET/MRI and MRI detected 96.7% of the primary tumors, whereas PET/ceCT detected 93.3%. Accuracy for T status was 80.0% for fused PET/MRI, and MRI proved significantly more accurate than PET/ceCT, which had an accuracy of 60.0% (p = 0.041). Patient-based sensitivity, specificity and accuracy for detecting pelvic nodal metastasis were 100%, 96.3% and 96.7% for both fused PET/MRI and PET/ceCT, and 66.7%, 100% and 96.7% for MRI, respectively. These three parameters were not statistically significant (p = 1). Conclusion: Fused PET/MRI, which complements the individual advantages of MRI and PET, is a valuable technique for assessment of the primary tumor and nodal staging in patients with endometrial cancer.

  5. Contrast-enhanced ultrasonography depicts small tumor vessels for the evaluation of pancreatic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Yuko [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Kawamoto, Hirofumi [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan)]. E-mail: h-kawamo@md.okayama-u.ac.jp; Takaki, Akinobu [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Ishida, Etsuji [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Ogawa, Tsuneyoshi [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Kuwaki, Kenji [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Kobayashi, Yoshiyuki [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Sakaguchi, Kohsaku [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan); Shiratori, Yasushi [Department of Gastroenterology and Hepatology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikata-cho, Okayama-city, Okayama 700-8558 (Japan)

    2007-01-15

    Objective: The aim of this study is to evaluate the efficacy of contrast-enhanced ultrasonography for the diagnosis of pancreatic tumors. Materials and methods: Contrast-enhanced ultrasonography with Levovist was performed on 62 consecutive patients (53 with pancreatic cancer, 4 with islet cell tumor, 3 with inflammatory pancreatic tumor, and 2 with metastatic tumor). The vascular and perfusion image phases of the tumors were evaluated and compared with the findings of contrast-enhanced computed tomography. Results: Contrast-enhanced ultrasonography showed tumor vessels around and/or in the tumor at the vascular image phase in 79% of pancreatic cancer patients (42/53). At the perfusion image phase, 96% of pancreatic cancers (51/53) were classified as hypo-enhancement type. However, tiny spotty or irregular heterogeneous enhanced lesions were found in 84% of hypo-enhanced pancreatic cancer patients (43/51). The presence of small vessels at the vascular image phase was closely correlated with the presence of these intratumor regional enhanced lesions at the perfusion image phase ({kappa} coefficient = 0.42). The sensitivity of contrast-enhanced ultrasonography (100%) for pancreatic cancer was superior to that of contrast-enhanced computed tomography (91%), but no significant difference was observed between the two (McNemar test: p = 0.063). Conclusion: Contrast-enhanced ultrasonography with Levovist successfully visualizes fine vessels and enhancement in pancreatic tumors, and is useful for evaluating pancreatic tumors.

  6. Fibroadenomas of the breast: histopathological/dynamic contrast-enhanced MR correlation

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, R. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Garnier, C. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Meingan, P. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Zemoura, L. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Lucidarme, O. [Dept. of Radiology, Hopital Salpetriere, 75 - Paris (France); Guinebretiere, J.M. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Tardivon, A.A. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Arriagada, R. [Breast Cancer Study Group, Inst. Gustave Roussy, 94 - Villejuif, (France)

    1995-12-31

    A total of 22 women with fibroadenomas had preoperative dynamic MR study (T1-weighted images every 47 s after injection of Gd-DOTA). Their age, hormonal status, breast MR studies and histopathological slides were retrospectively reviewed. Eleven pre- (n = 2) or post-menopausal (n = 9) women showed no early contrast enhancement. The absence of early contrast enhancement correlated with hyalin stromal component. Eleven pre- (n = 7) or post-menopausal (n = 4) women showed focal (n = 9) or diffuse (n = 2) early contrast enhancement. Early focal contrast enhancement correlated with myxoid (n = 9), mixed hyalin/myxoid (n = 1) or hyalin (n = 1) fibroadenomas. Early diffuse contrast enhancement of the breast correlated with myxoid (n = 1) or hyalin (n = 1) stromal component associated with proliferative fibrocystic disease of the breast parenchyma. The presence of contrast enhancement correlated with myxoid fibroadenomas, whereas absence of contrast enhancement correlated with hyalin fibroadenomas. As hyalin fibroadenomas occurs in post-menopausal women, the diagnostic accuracy of dynamic MRI may be improved in this age group. (orig.)

  7. Impact of image acquisition timing on image quality for dual energy contrast-enhanced breast tomosynthesis

    Science.gov (United States)

    Hill, Melissa L.; Mainprize, James G.; Puong, Sylvie; Carton, Ann-Katherine; Iordache, Razvan; Muller, Serge; Yaffe, Martin J.

    2012-03-01

    Dual-energy contrast-enhanced digital breast tomosynthesis (DE CE-DBT) image quality is affected by a large parameter space including the tomosynthesis acquisition geometry, imaging technique factors, the choice of reconstruction algorithm, and the subject breast characteristics. The influence of most of these factors on reconstructed image quality is well understood for DBT. However, due to the contrast agent uptake kinetics in CE imaging, the subject breast characteristics change over time, presenting a challenge for optimization . In this work we experimentally evaluate the sensitivity of the reconstructed image quality to timing of the low-energy and high-energy images and changes in iodine concentration during image acquisition. For four contrast uptake patterns, a variety of acquisition protocols were tested with different timing and geometry. The influence of the choice of reconstruction algorithm (SART or FBP) was also assessed. Image quality was evaluated in terms of the lesion signal-difference-to-noise ratio (LSDNR) in the central slice of DE CE-DBT reconstructions. Results suggest that for maximum image quality, the low- and high-energy image acquisitions should be made within one x-ray tube sweep, as separate low- and high-energy tube sweeps can degrade LSDNR. In terms of LSDNR per square-root dose, the image quality is nearly equal between SART reconstructions with 9 and 15 angular views, but using fewer angular views can result in a significant improvement in the quantitative accuracy of the reconstructions due to the shorter imaging time interval.

  8. Diagnosis of hepatic steatosis by contrast-enhanced abdominal computed tomography; Diagnostico da esteatose hepatica pela tomografia computadorizada de abdome com meio de contraste intravenoso

    Energy Technology Data Exchange (ETDEWEB)

    Monjardim, Rodrigo da Fonseca; Costa, Danilo Manuel Cerqueira; Romano, Ricardo Francisco Tavares; Salvadori, Priscila Silveira; Santos, Jaime de Vargas Conde dos; Atzingen, Augusto Castelli Von; Shigueoka, David Carlos; D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Universidade Federal de Sao Paulo (EPM/UNIFESP), SP (Brazil). Escola Paulista de Medicina. Dept. de Diagnostico por Imagem

    2013-05-15

    Objective: to evaluate the diagnostic capacity of abdominal computed tomography in the assessment of hepatic steatosis using the portal phase with a simplified calculation method as compared with the non-contrast-enhanced phase. Materials and methods: in the present study, 150 patients were retrospectively evaluated by means of non-contrast-enhanced and contrast-enhanced computed tomography. One hundred patients had hepatic steatosis and 50 were control subjects. For the diagnosis of hepatic steatosis in the portal phase, the authors considered a result of < 104 HU calculated by the formula [L - 0.3 Multiplication-Sign (0.75 Multiplication-Sign P + 0.25 Multiplication-Sign A)] / 0.7, where L, P and A represent the attenuation of the liver, of the main portal vein and abdominal aorta, respectively. Sensitivity, specificity, positive and negative predictive values were calculated, using non-contrast-enhanced computed tomography as the reference standard. Results: the simplified calculation method with portal phase for the diagnosis of hepatic steatosis showed 100% sensitivity, 36% specificity, negative predictive value of 100% and positive predictive value of 75.8%. The rate of false positive results was 64%. False negative results were not observed. Conclusion: The portal phase presents an excellent sensitivity in the diagnosis of hepatic steatosis, as compared with the non-contrast-enhanced phase of abdominal computed tomography. However, the method has low specificity. (author)

  9. Contrast-enhanced spectral mammography versus MRI: Initial results in the detection of breast cancer and assessment of tumour size.

    Science.gov (United States)

    Fallenberg, E M; Dromain, C; Diekmann, F; Engelken, F; Krohn, M; Singh, J M; Ingold-Heppner, B; Winzer, K J; Bick, U; Renz, D M

    2014-01-01

    To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard. After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation. Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology. Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography (CESM) is slowly being introduced into clinical practice. • Access to breast MRI is limited by availability and lack of reimbursement. • Initial results show a better sensitivity of CESM and MRI than conventional mammography. • CESM showed a good correlation with postoperative histology in size assessment. • Contrast-enhanced spectral mammography offers promise, seemingly providing information comparable to MRI.

  10. Non-contrast enhanced navigator-gated balanced steady state free precession magnetic resonance angiography as a preferred magnetic resonance technique for assessment of the thoracic aorta

    NARCIS (Netherlands)

    van Kesteren, F.; Elattar, M. A.; van Lienden, K. P.; Baan, J.; Marquering, H. A.; Planken, R. N.

    2017-01-01

    AIM: To compare the objective and subjective image quality of non-contrast three-dimensional (3D) navigator-gated balanced steady state free precession magnetic resonance angiography (NC-MRA) and contrast-enhanced magnetic resonance angiography (CE-MRA) along the entire thoracic aorta. MATERIALS AND

  11. Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast-enhanced MRI alone and in combination: preliminary experience.

    NARCIS (Netherlands)

    Patel, J.; Sigmund, E.E.; Rusinek, H.; Oei, M.T.H.; Babb, J.S.; Taouli, B.

    2010-01-01

    PURPOSE: To report our preliminary experience with the use of intravoxel incoherent motion (IVIM) diffusion-weighted magnetic resonance imaging (DW-MRI) and dynamic contrast-enhanced (DCE)-MRI alone and in combination for the diagnosis of liver cirrhosis. MATERIALS AND METHODS: Thirty subjects (16

  12. The Performance of Noncontrast Magnetic Resonance Angiography in Detecting Renal Artery Stenosis as Compared With Contrast Enhanced Magnetic Resonance Angiography Using Conventional Angiography as a Reference.

    Science.gov (United States)

    Liang, Keng-Wei; Chen, Jhih-Wei; Huang, Hsin-Hui; Su, Chun-Hung; Tyan, Yeu-Sheng; Tsao, Teng-Fu

    The aims of this study were to evaluate the performance of noncontrast magnetic resonance angiography (NC MRA) for detecting renal artery stenosis (RAS) as compared with contrast-enhanced magnetic resonance angiography (CE MRA) and to evaluate the clinical feasibility, technical success rate, and performance of NC MRA for detecting RAS as compared with CE MRA. Thirty-six subjects who underwent NC MRA and/or CE MRA were enrolled. Feasibility, technical success rate, and image quality scores were compared. Diagnostic ability was calculated using conventional angiography as a reference. Noncontrast MRA had higher feasibility and technical success rates than CE MRA did (100% and 97.2% vs 83.3% and 90%, respectively). Noncontrast MRA yielded significantly better image quality in motion artifact (P = 0.016). The diagnostic ability for detecting RAS is without significant difference between NC MRA and CE MRA. Although NC MRA and CE MRA demonstrated comparable ability in diagnosing RAS, NC MRA achieved better technical success rates, feasibility, and image quality in motion artifacts than CE MRA did.

  13. Technical innovation in dynamic contrast-enhanced magnetic resonance imaging of musculoskeletal tumors: an MR angiographic sequence using a sparse k-space sampling strategy.

    Science.gov (United States)

    Fayad, Laura M; Mugera, Charles; Soldatos, Theodoros; Flammang, Aaron; del Grande, Filippo

    2013-07-01

    We demonstrate the clinical use of an MR angiography sequence performed with sparse k-space sampling (MRA), as a method for dynamic contrast-enhanced (DCE)-MRI, and apply it to the assessment of sarcomas for treatment response. Three subjects with sarcomas (2 with osteosarcoma, 1 with high-grade soft tissue sarcomas) underwent MRI after neoadjuvant therapy/prior to surgery, with conventional MRI (T1-weighted, fluid-sensitive, static post-contrast T1-weighted sequences) and DCE-MRI (MRA, time resolution = 7-10 s, TR/TE 2.4/0.9 ms, FOV 40 cm(2)). Images were reviewed by two observers in consensus who recorded image quality (1 = diagnostic, no significant artifacts, 2 = diagnostic, 75 % with good response, >75 % with poor response). DCE-MRI findings were concordant with histological response (arterial enhancement with poor response, no arterial enhancement with good response). Unlike conventional DCE-MRI sequences, an MRA sequence with sparse k-space sampling is easily integrated into a routine musculoskeletal tumor MRI protocol, with high diagnostic quality. In this preliminary work, tumor enhancement characteristics by DCE-MRI were used to assess treatment response.

  14. Hemodynamic changes on color Doppler flow imaging and intravenous contrast-enhanced ultrasound for assessing transplanted liver and early diagnosis of complications.

    Science.gov (United States)

    Huang, Daozhong; Chen, Yunchao; Li, Kaiyan; Zhang, Qingping

    2008-06-01

    The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation. And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls. The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (Pliver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS.

  15. Biliary complications following orthotopic liver transplantation: May contrast-enhanced MR Cholangiography provide additional information?

    Directory of Open Access Journals (Sweden)

    Piero Boraschi

    2016-01-01

    Conclusions: Contrast-enhanced T1-weighted MR Cholangiography may improve the level of diagnostic confidence provided by conventional T2-weighted MR Cholangiography in the evaluation of biliary complications after orthotopic liver transplantation.

  16. Description of the use of contrast-enhanced ultrasonography in four dogs with pancreatic tumours.

    Science.gov (United States)

    Vanderperren, K; Haers, H; Van der Vekens, E; Stock, E; Paepe, D; Daminet, S; Saunders, J H

    2014-03-01

    Canine pancreatic tumours are rare compared to human medicine and the detection and differentiation of pancreatic neoplasia is challenging with B-mode ultrasonography, which often leads to late clinical diagnosis and poor prognosis. This case report describes the findings of contrast-enhanced ultrasonography in four dogs with pancreatic adenocarcinoma or insulinoma. B-mode ultrasonography of the pancreas revealed a hypoechoic nodule in three dogs and heterogenous tissue in one dog. Contrast-enhanced ultrasonography was able to differentiate between two tumour types: adenocarcinomas showed hypoechoic and hypovascular lesions, whereas insulinomas showed uniformly hypervascular lesions. Contrast-enhanced ultrasonography findings were confirmed by cytology and/or histopathology. The results demonstrated that contrast-enhanced ultrasonography was able to establish different enhancement patterns between exocrine (adenocarcinoma) and endocrine (insulinoma) tumours in dogs.

  17. Contrast-enhanced ultrasonographic findings in three dogs with lung lobe torsion.

    Science.gov (United States)

    Caivano, Domenico; Birettoni, Francesco; Bufalari, Antonello; De Monte, Valentina; Angeli, Giovanni; Giorgi, Maria Elena; Patata, Valentina; Porciello, Francesco

    2016-03-01

    Lung lobe torsion is rare but life-threatening condition in the dog. Thoracic radiographs and conventional ultrasonography cannot be conclusive for the diagnosis, and computed tomography is useful but is limited by cost and availability. This report describes the findings of contrast-enhanced ultrasonography in 3 dogs with lung lobe torsion. Contrast-enhanced ultrasonography showed the absence or reduction of pulmonary vascularization secondary to twisting of the lung lobe around its bronchovascular pedicle in all three dogs. Moreover, contrast-enhanced ultrasonography distinguished partial pulmonary atelectasis from a lung lobe torsion. These preliminary results suggest that contrast-enhanced ultrasonography can improve the accuracy of conventional ultrasonography for detection of pulmonary blood flow compromise in dogs with lung lobe torsion.

  18. Reproducibility of rest and exercise stress contrast-enhanced calf perfusion magnetic resonance imaging in peripheral arterial disease

    Directory of Open Access Journals (Sweden)

    Jiji Ronny S

    2013-01-01

    Full Text Available Abstract Background The purpose was to determine the reproducibility and utility of rest, exercise, and perfusion reserve (PR measures by contrast-enhanced (CE calf perfusion magnetic resonance imaging (MRI of the calf in normal subjects (NL and patients with peripheral arterial disease (PAD. Methods Eleven PAD patients with claudication (ankle-brachial index 0.67 ±0.14 and 16 age-matched NL underwent symptom-limited CE-MRI using a pedal ergometer. Tissue perfusion and arterial input were measured at rest and peak exercise after injection of 0.1 mM/kg of gadolinium-diethylnetriamine pentaacetic acid (Gd-DTPA. Tissue function (TF and arterial input function (AIF measurements were made from the slope of time-intensity curves in muscle and artery, respectively, and normalized to proton density signal to correct for coil inhomogeneity. Perfusion index (PI = TF/AIF. Perfusion reserve (PR = exercise TF/ rest TF. Intraclass correlation coefficient (ICC was calculated from 11 NL and 10 PAD with repeated MRI on a different day. Results Resting TF was low in NL and PAD (mean ± SD 0.25 ± 0.18 vs 0.35 ± 0.71, p = 0.59 but reproducible (ICC 0.76. Exercise TF was higher in NL than PAD (5.5 ± 3.2 vs. 3.4 ± 1.6, p = 0.04. Perfusion reserve was similar between groups and highly variable (28.6 ± 19.8 vs. 42.6 ± 41.0, p = 0.26. Exercise TF and PI were reproducible measures (ICC 0.63 and 0.60, respectively. Conclusion Although rest measures are reproducible, they are quite low, do not distinguish NL from PAD, and lead to variability in perfusion reserve measures. Exercise TF and PI are the most reproducible MRI perfusion measures in PAD for use in clinical trials.

  19. Contrast-enhanced CT and diffusion-weighted MR imaging: Performance as a prognostic factor in patients with pancreatic ductal adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fukukura, Yoshihiko, E-mail: fukukura@m.kufm.kagoshima-u.ac.jp [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Takumi, Koji [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Higashi, Michiyo [Department of Human Pathology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Shinchi, Hiroyuki [Department of Surgical Oncology and Digestive Surgery, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan); Kamimura, Kiyohisa; Yoneyama, Tomohide; Tateyama, Akihiro [Department of Radiology, Kagoshima University Graduate School of Medical and Dental Sciences, 8-35-1 Sakuragaoka, Kagoshima City 890-8544 (Japan)

    2014-04-15

    Objective: To determine whether contrast enhancement of CT and apparent diffusion coefficient on diffusion-weighted MR imaging are important parameters that can predict outcomes for patients with pancreatic ductal adenocarcinoma. Materials and methods: Ninety-two patients with histologically confirmed pancreatic ductal adenocarcinoma who underwent quadriphasic CT (including unenhanced, pancreatic parenchymal, portal venous and delayed phases) and fat-suppressed single-shot echo-planar diffusion-weighted MR imaging at 3.0 T were retrospectively analyzed to investigate prognostic factors. Overall survival curves were drawn using the Kaplan–Meier method. Effects on survival of variables including age, sex, tumor location, tumor size, TNM stage, carbohydrate antigen 19-9, carcinoembryonic antigen, treatment, tumor contrast enhancement and apparent diffusion coefficient values were analyzed in univariate analysis using the log-rank test. Variables were analyzed in multivariate analyses using the Cox proportional hazards regression model. Results: Median survival for the entire patient population was 18.2 months. Higher contrast enhancement during all phases was associated with significantly longer overall survival (P < 0.001 for all phases). The difference in overall survival between groups divided by median apparent diffusion coefficient value was not significant (P = 0.672). TNM stage (P = 0.026) and tumor contrast enhancement on CT (P = 0.027) were significantly related to survival in multivariate analysis. Conclusions: Poor enhancement of pancreatic adenocarcinomas on enhanced CT is associated with reduced patient survival.

  20. Diagnostic accuracy of unenhanced, contrast-enhanced perfusion and angiographic MRI sequences for pulmonary embolism diagnosis: results of independent sequence readings

    Energy Technology Data Exchange (ETDEWEB)

    Revel, Marie Pierre [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Hotel-Dieu, Service de Radiologie, Paris (France); Sanchez, Olivier; Meyer, Guy [Hopital Europeen Georges Pompidou, APHP, Respiratory and intensive care and, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM Unite 765, Paris (France); Lefort, Catherine; Couchon, Sophie; Hernigou, Anne; Frija, Guy [Hopital Europeen Georges Pompidou, APHP, Departments of Radiology, Paris (France); Niarra, Ralph [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); Chatellier, Gilles [Hopital Europeen Georges Pompidou, APHP, Clinical Epidemiology, Paris (France); Universite Paris Descartes Sorbonne Paris Cite, Paris (France); INSERM CIC-EC E4, Paris (France)

    2013-09-15

    To independently evaluate unenhanced, contrast-enhanced perfusion and angiographic MR sequences for pulmonary embolism (PE) diagnosis. Prospective investigation, including 274 patients who underwent perfusion, unenhanced 2D steady-state-free-precession (SSFP) and contrast-enhanced 3D angiographic MR sequences on a 1.5-T unit, in addition to CTA (CT angiography). Two independent readers evaluated each sequence independently in random order. Sensitivity, specificity, predictive values and inter-reader agreement were calculated for each sequence, excluding sequences judged inconclusive. Sensitivity was also calculated according to PE location. Contrast-enhanced angiographic sequences showed the highest sensitivity (82.9 and 89.7 %, reader 1 and reader 2, respectively), specificity (98.5 and 100 %) and agreement (kappa value 0.77). Unenhanced angiographic sequences, although less sensitive overall (68.7 and 76.4 %), were sensitive for the detection of proximal PE (92.7 and 100 %) and showed high specificity (96.1 and 99.1 %) and good agreement (kappa value 0.62). Perfusion sequences showed lower sensitivity (75.0 and 79.3 %), specificity (84.8 and 89.7 %) and agreement (kappa value 0.51), and a negative predictive value of 84.8 % at best. Compared with contrast-enhanced angiographic sequences, unenhanced sequences demonstrate lower sensitivity, except for proximal PE, but high specificity and agreement. The negative predictive value of perfusion sequences was insufficient to safely rule out PE. (orig.)

  1. An Improved Local Equilibrium Contrast Enhancement Algorithm for Infrared Laser Images

    OpenAIRE

    Yuhong Li; Jianzhong Zhou; Wei Ding; Shan Ding

    2010-01-01

    An improved local equilibrium contrast enhancement algorithm based self-adaptive contrast enhancement algorithm is proposed for infrared laser images, in which the image pixel value histogram is divided into three parts: background and noise area, targets area, and uninterested area. The targets parts are highlighted, while the background and noise parts and the uninterested parts are restrained. A comprehensive qualitative and quantitative image enhancement performance evaluation is presente...

  2. Histological change and microcirculation in the contrast-enhancement region of cerebral infarction. An experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, Tetsuya; Takemura, Kiyoshi; Sakaki, Toshisuke; Hori, Yutaka (Nara National Hospital, Nara (Japan)); Yokoyama, Kazuhiro

    1983-08-01

    The purpose of this experiment is to reveal the microcirculation and blood-brain barrier by comparison with the histological findings in the contrast-enhancement region. The microcirculation is studied by carbon perfusion, and the function of the blood-brain barrier is studied by the intravenous administration of fluorescein. According to the carbon perfusion, carbon filling is impaired in the ischemic region of cerebral infarction. However, partially in the ischemic region, there is a good carbon-filling zone, called the carbon deposit, which indicates that the microcirculation develops better in this part of the ischemic region during the contrast-enhancement stage. From the histological point of view, the contrast-enhancement region contains capillaries and phagocytes and has a spongy appearance, an extravasation of red cells, and cavity formations. The density of capillaries might play the most important role in the microcirculation and the function of the blood-brain barrier. The fluorescein stain indicates the extent of the abnormally increased permeability of the capillaries. During the contrast-enhancement stage, the fluorescein stain is found not only in the contrast-enhacement region, but also in the surrounding zone around the contrast-enhancement region. There is an ischemic histological change, shown by the spongy appearance in this surrounding zone with the fluorescein stain. On a CT scan, this surrounding zone is seen as a normodensity area in most experimental models. These results indicate that, during the stage of the contrast-enhancement of cerebral infarction, a histologically evidenced ischemic area is detected not only as a contrast-enhancement region but also as a normodensity area around the contrast-enhancement region.

  3. The role of contrast-enhanced ultrasonography in image-guided liver ablations

    Energy Technology Data Exchange (ETDEWEB)

    Pescatori, Lorenzo Carlo [Postgraduate School in Radiodiagnostics, University Studi di Milano, Milan (Italy); Sconfienza, Luca Maria; Mauri, Giovanni [Radiology Unit, Policlinico San Donato Research Hospital, Milan (Italy)

    2016-01-15

    We read with great interest the paper by Kim et al. entitled “Local ablation therapy with contrast enhanced ultrasonography for hepatocellular carcinoma: a practical review,” recently published in Ultrasonography. We think that contrast-enhanced ultrasonography (CEUS), together with the development of reliable navigation systems, is likely to represent one of the most important advances in image-guided ablations in recent years. Thus, we offer some considerations on the topic.

  4. Contrast-enhanced CMR in patients after percutaneous closure of the left atrial appendage: A pilot study

    Directory of Open Access Journals (Sweden)

    Petersen Steffen E

    2011-07-01

    Full Text Available Abstract Background To evaluate the feasibility and value of first-pass contrast-enhanced dynamic and post-contrast 3D CMR in patients after transcatheter occlusion of left atrial appendage (LAA to identify incorrect placement and persistent leaks. Methods 7 patients with different occluder systems (n = 4 PLAATO; n = 2 Watchman; n = 1 ACP underwent 2 contrast-enhanced (Gd-DOTA CMR sequences (2D TrueFISP first-pass perfusion and 3D-TurboFLASH to assess localization, artifact size and potential leaks of the devices. Perfusion CMR was analyzed visually and semi-quantitatively to identify potential leaks. Results All occluders were positioned within the LAA. The ACP occluder presented the most extensive artifact size. Visual assessment revealed a residual perfusion of the LAA apex in 4 cases using first-pass perfusion and 3D-TurboFLASH indicating a suboptimal LAA occlusion. By assessing signal-to-time-curves the cases with a visually detected leak showed a 9-fold higher signal-peak in the LAA apex (567 ± 120% increase from baseline signal than those without a leak (61 ± 22%; p Conclusion This CMR pilot study provides valuable non-invasive information in patients after transcatheter occlusion of the LAA to identify correct placement and potential leaks. We recommend incorporating CMR in future clinical studies to evaluate new device types.

  5. Contrast-Enhanced Ultrasound Using Perfluorobutane-Containing Microbubbles in the Assessment of Liver Allograft Damage: An Exploratory Prospective Study.

    Science.gov (United States)

    Joo, Ijin; Lee, Jae Young; Lee, Dong Ho; Jeon, Ju Hyeon; Kim, Hyeyoung; Yi, Nam-Joon; Lee, Kwang-Woong; Suh, Kyung-Suk

    2017-03-01

    This prospective study investigated the usefulness of contrast (perfluorobutane-containing microbubbles)-enhanced ultrasound in the non-invasive assessment of liver allograft damage. Forty-one liver recipients underwent contrast-enhanced ultrasound followed by a liver biopsy. The hepatic filling rate (time between the arrival of contrast agent in the right hepatic artery and the maximum intensity of hepatic parenchyma) and parenchymal intensity difference before and after instantaneous high-power emission in the Kupffer phase were measured. Patients with allograft damage had higher hepatic filling rates and lower parenchymal intensity differences than those without damage (42.0 ± 16.9 vs. 30.5 ± 7.7 s, p = 0.005; 6.1 ± 7.4 vs. 16.6 ± 16.1 dB, p = 0.047, respectively). In the diagnosis of liver allograft damage, hepatic filling rate and parenchymal intensity difference had sensitivities of 61.5% and 90.9% and specificities of 92.6% and 63.6% using cutoffs of >38.5 s and ≤10.3 dB, respectively. In conclusion, contrast-enhanced ultrasound may be a promising tool in the detection of liver allograft damage. Copyright © 2016. Published by Elsevier Inc.

  6. The Usefulness of Contrast-Enhanced Ultrasound in the Assessment of Early Kidney Transplant Function and Complications.

    Science.gov (United States)

    Álvarez Rodríguez, Sara; Hevia Palacios, Vital; Sanz Mayayo, Enrique; Gómez Dos Santos, Victoria; Díez Nicolás, Víctor; Sánchez Gallego, María Dolores; Lorca Álvaro, Javier; Burgos Revilla, Francisco Javier

    2017-09-15

    The routine diagnostic method for assessment of renal graft dysfunction is Doppler ultrasound. However, contrast-enhanced ultrasound (CEUS) may provide more information about parenchymal flow and vascular status of kidney allografts. The aim of the study was to assess the effectiveness of CEUS in the immediate post-transplant period, focusing on acute vascular complications. A brief review of available literature and a report of our initial experience is made. 15 kidney transplant (KT) cases with clinical suspicion of acute surgical complication were assessed with CEUS and conventional Doppler ultrasound (US). In addition, bibliographic review was conducted through PubMed, Embase, and ClinicalKey databases. 10% of KT underwent CEUS, useful for detecting vascular complication or cortical necrosis in 4 (26%) and exclude them in 74%. Grafts with acute vascular complications have a delayed contrast-enhancement with peak intensity lower than normal kidneys. Perfusion defects can be clearly observed and the imaging of cortical necrosis is pathognomonic. CEUS is a useful tool in the characterization of renal graft dysfunction with special interest on acute vascular complications after renal transplant. It is a feasible technique for quantitative analysis of kidney perfusion, which provides information on renal tissue microcirculation and regional parenchymal flow. Exploration could be done by a urologist at the patient's bedside while avoiding iodinated contrast.

  7. A prospective study on contrast-enhanced magnetic resonance imaging of testicular lesions: distinctive features of Leydig cell tumours

    Energy Technology Data Exchange (ETDEWEB)

    Manganaro, Lucia; Vinci, Valeria; Saldari, Matteo; Bernardo, Silvia; Cantisani, Vito; Catalano, Carlo [Sapienza University of Rome, Department of Radiology, Rome (Italy); Pozza, Carlotta; Gianfrilli, Daniele; Pofi, Riccardo; Lenzi, Andrea; Isidori, Andrea M. [Sapienza University of Rome, Department of Experimental Medicine, Rome (Italy); Scialpi, Michele [Perugia University, S. Maria della Misericordia Hospital, Department of Surgical and Biomedical Sciences, Division of Radiology 2, Perugia (Italy)

    2015-12-15

    Up to 20 % of incidentally found testicular lesions are benign Leydig cell tumours (LCTs). This study evaluates the role of contrast-enhanced magnetic resonance imaging (MRI) in the identification of LCTs in a large prospective cohort study. We enrolled 44 consecutive patients with at least one solid non-palpable testicular lesion who underwent scrotal MRI. Margins of the lesions, signal intensity and pattern of wash-in and wash-out were analysed by two radiologists. The frequency distribution of malignant and benign MRI features in the different groups was compared by using the chi-squared or Fisher's exact test. Sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy were calculated. The sensitivity of scrotal MRI to diagnose LCTs was 89.47 % with 95.65 % specificity; sensitivity for malignant lesions was 95.65 % with 80.95 % specificity. A markedly hypointense signal on T2-WI, rapid and marked wash-in followed by a prolonged washout were distinctive features significantly associated with LCTs. Malignant lesions were significantly associated with blurred margins, weak hypointense signal on T2-WI,and weak and progressive wash-in. The overall diagnostic accuracy was 93 %. LCTs have distinctive contrast-enhanced MRI features that allow the differential diagnosis of incidental testicular lesions. (orig.)

  8. Dynamic contrast-enhanced MR imaging of endometrial cancer. Optimizing the imaging delay for tumour-myometrium contrast

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Bin [Chung-Ang University Hospital, Chung-Ang University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Moon, Min Hoan; Sung, Chang Kyu [Seoul National University College of Medicine, 41, Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); Oh, Sohee [Seoul National University College of Medicine, 41, Department of Biostatistics, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); Lee, Young Ho [Kwandong University College of Medicine, Department of Radiology, Cheil General Hospital and Women' s Healthcare Center, Seoul (Korea, Republic of)

    2014-11-15

    To investigate the optimal imaging delay time of dynamic contrast-enhanced magnetic resonance (MR) imaging in women with endometrial cancer. This prospective single-institution study was approved by the institutional review board, and informed consent was obtained from the participants. Thirty-five women (mean age, 54 years; age range, 29-66 years) underwent dynamic contrast-enhanced MR imaging with a temporal resolution of 25-40 seconds. The signal intensity difference ratios between the myometrium and endometrial cancer were analyzed to investigate the optimal imaging delay time using single change-point analysis. The optimal imaging delay time for appropriate tumour-myometrium contrast ranged from 31.7 to 268.1 seconds. The median optimal imaging delay time was 91.3 seconds, with an interquartile range of 46.2 to 119.5 seconds. The median signal intensity difference ratios between the myometrium and endometrial cancer were 0.03, with an interquartile range of -0.01 to 0.06, on the pre-contrast MR imaging and 0.20, with an interquartile range of 0.15 to 0.25, on the post-contrast MR imaging. An imaging delay of approximately 90 seconds after initiating contrast material injection may be optimal for obtaining appropriate tumour-myometrium contrast in women with endometrial cancer. (orig.)

  9. Visualization of novel microstents in patients with unruptured intracranial aneurysms with contrast-enhanced flat panel detector CT.

    Science.gov (United States)

    Poncyljusz, Wojciech; Zwarzany, Łukasz; Safranow, Krzysztof

    2015-07-01

    The aim of our study was to evaluate the feasibility of contrast-enhanced flat panel detector CT (FPDCT) for visualizing the novel microstents implanted in patients with unruptured wide-necked intracranial aneurysms. Forty-four cases of patients who underwent stent assisted coiling at our department were retrospectively analyzed. In each case, FPDCT images were performed after stent and coils deployment and then assessed in the terms of stent struts and all radiopaque markers and tantalum strands visibility separately using a 3-grade scale (1 - inadequate, 2 - good, 3 - excellent). Stent struts visibility was assessed to be inadequate for evaluation in all cases. All radiopaque markers and tantalum strands visibility was excellent in 61.4% and good in 38.6% of cases. We observed 4 (9.09%) cases of incomplete stent opening. Treated aneurysm size <10mm was an independent predictor of excellent stent all radiopaque markers and tantalum strands visibility (ρ=0.014). Contrast-enhanced FPDCT is feasible for visualizing stents implanted in patients with intracranial aneurysms as it gives precise visualization of the relationships between the stent tantalum strands and the vessel wall. Stents used in the treatment of aneurysms ≥10 mm in size are worse visualized because of the coil streaking artifacts. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Visualization of novel microstents in patients with unruptured intracranial aneurysms with contrast-enhanced flat panel detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Poncyljusz, Wojciech, E-mail: wponcyl@poczta.onet.pl [Departament of Interventional Radiology, Pomeranian Medical University, Neurointerventional Cath Lab MSW Hospital, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland); Zwarzany, Łukasz, E-mail: zwarzany@gmail.com [Departament of Interventional Radiology, Pomeranian Medical University, Neurointerventional Cath Lab MSW Hospital, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland); Safranow, Krzysztof, E-mail: chrissaf@mp.pl [Department of Biochemistry and Chemistry, Pomeranian Medical University, Al. Powst. Wielkopolskich 72, 70-111 Szczecin (Poland)

    2015-07-15

    Highlights: • We examine the feasibility of FPDCT for visualizing intracranial microstents. • Stent deployment and its apposition to the vessel wall are easily assessable. • Coil streaking artifacts hamper the assessment of stent visibility. - Abstract: Objectives: The aim of our study was to evaluate the feasibility of contrast-enhanced flat panel detector CT (FPDCT) for visualizing the novel microstents implanted in patients with unruptured wide-necked intracranial aneurysms. Methods: Forty-four cases of patients who underwent stent assisted coiling at our department were retrospectively analyzed. In each case, FPDCT images were performed after stent and coils deployment and then assessed in the terms of stent struts and all radiopaque markers and tantalum strands visibility separately using a 3-grade scale (1 – inadequate, 2 – good, 3 – excellent). Results: Stent struts visibility was assessed to be inadequate for evaluation in all cases. All radiopaque markers and tantalum strands visibility was excellent in 61.4% and good in 38.6% of cases. We observed 4 (9.09%) cases of incomplete stent opening. Treated aneurysm size <10 mm was an independent predictor of excellent stent all radiopaque markers and tantalum strands visibility (ρ = 0.014). Conclusions: Contrast-enhanced FPDCT is feasible for visualizing stents implanted in patients with intracranial aneurysms as it gives precise visualization of the relationships between the stent tantalum strands and the vessel wall. Stents used in the treatment of aneurysms ≥10 mm in size are worse visualized because of the coil streaking artifacts.

  11. Diagnostic and prognostic values of contrast-enhanced ultrasound in breast cancer: a retrospective study.

    Science.gov (United States)

    Zhao, Yi-Xuan; Liu, Shuang; Hu, Yan-Bing; Ge, Yan-Yan; Lv, Dong-Mei

    2017-01-01

    This study aimed to explore the diagnostic and prognostic values of contrast-enhanced ultrasound (CEUS) in breast cancer. Between September 2009 and October 2011, a total of 143 breast cancer patients and 161 healthy people were selected as case group and control group, respectively. After the identification of lesions by conventional ultrasound, all patients underwent CEUS. The CEUS images were analyzed, and time-intensity curves (TICs) were obtained. Hematoxylin-eosin and immunohistochemistry staining was performed on tissue specimens, according to which the expressions of estrogen receptor (ER), c-erb-B2, p53, and Ki-67 were measured. Multivariate logistic regression analysis was used to compare CEUS and TIC parameters between the two groups. Compared with the control group, cancer patients showed high enhancement, heterogeneous enhancement or defects in the central region, expansion of lesion diameter after enhancement and crab-like blur lesion edges. The peak intensity (PI), relative start time of enhancement, relative PI, and relative area under the curve in the case group were significantly higher than those in the control group. Logistic analysis showed that the uniformity of enhancement, expansion of lesion diameter, and relative PI were significant diagnostic parameters of breast cancer, with area under the curve being 0.798, 0.776, and 0.919, respectively. There were strong associations between CEUS characteristics and expressions of prognostic factors in breast cancer: the heterogeneous enhancement was common in c-erb-B2-positive tumors; the centripetal enhancement occurred more in ER-negative tumors; perforator vessels were often seen in tumors at high histological grade; perfusion defects were common in ER-negative, c-erb-B2-positive, and Ki-67-positive tumors. CEUS is a useful tool for the early diagnosis and prognosis of breast cancer.

  12. Prostate dynamic contrast-enhanced MRI with simple visual diagnostic criteria: is it reasonable?

    Energy Technology Data Exchange (ETDEWEB)

    Girouin, Nicolas; Tonina Senes, Alejandro [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urinary and Vascular Radiology, Lyon (France); Mege-Lechevallier, Florence [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Histopathology, Lyon (France); Bissery, Alvine; Rabilloud, Muriel [Department of Biostatistics, Hospices Civils de Lyon, Lyon (France); Lyon, F-69003, France; Universite de Lyon 1, Laboratoire Biostatistiques-Sante, Universite de Lyon, Pierre-Benite (France); Marechal, Jean-Marie [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urology, Lyon (France); Colombel, Marc [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urology, Lyon (France); Lyon, F-69003, France; Universite de Lyon 1, Faculte de Medecine Lyon Nord, Universite de Lyon, Lyon (France); Lyonnet, Denis; Rouviere, Olivier [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urinary and Vascular Radiology, Lyon (France); Lyon, F-69003, France; Universite de Lyon 1, Faculte de Medecine Lyon Nord, Universite de Lyon, Lyon (France); Inserm, U556, Lyon (France)

    2007-06-15

    The purpose of this study was to evaluate the accuracy of prostate cancer localization with simple visual diagnostic criteria using dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). A total of 46 consecutive patients with biopsy-proven prostate cancer underwent prostate 1.5 T MRI with pelvic phased-array coils before prostatectomy. Besides the usual T2-weighted sequences, a 30-s DCE sequence was acquired three times after gadoterate injection. On DCE images, all early enhancing lesions of the peripheral zone were considered malignant. In the central gland, only early enhancing lesions appearing homogeneous or invading the peripheral zone were considered malignant. Three readers specified the presence of cancer in 20 prostate sectors and the location of distinct tumors. Results were compared with histology; p < 0.05 was considered significant. For localization of cancer in the sectors, DCE imaging had a significantly higher sensitivity [logistic regression, odds ratio (OR): 3.9, p < 0.0001] and a slightly but significantly lower specificity (OR: 0.57, p < 0.0001). Of the tumors >0.3 cc, 50-60% and 78-81% were correctly depicted with T2-weighted and DCE imaging, respectively. For both techniques, the depiction rate of tumors >0.3 cc was significantly influenced by the Gleason score (most Gleason {<=}6 tumors were overlooked), but not by the tumor volume. DCE-MRI using pelvic phased-array coils and simple visual diagnostic criteria is more sensitive for tumor localization than T2-weighted imaging. (orig.)

  13. Optimal breathing protocol for dynamic contrast-enhanced MRI of solitary pulmonary nodules at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Kino, Aya; Takahashi, Masaya [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Ashiku, Simon K.; Decamp, Malcolm M. [Section of Thoracic Surgery, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Lenkinski, Robert E. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Hatabu, Hiroto [Department of Radiology and Center for Pulmonary Functional Imaging, Brigham and Women' s Hospital, 75 Francis Street, Boston, MA 02115 (United States)], E-mail: hhatabu@partners.org

    2007-12-15

    The purpose of this study was to evaluate optimal breathing maneuvers that minimize lung parenchymal movement for dynamic contrast-enhanced MRI (DCE-MRI), which requires longer scan times, beyond the limit of a single breath hold. A healthy volunteer was scanned on a 3 T MR scanner using two different breathing maneuvers. In the first, the healthy volunteer was instructed to hold his breath as much as possible and breathe in between breath holds while an image was obtained. In the second, the volunteer was instructed to breathe shallowly and freely throughout the scan. On the obtained images, the excursion of the highest point of the right diaphragm and the pulmonary vessel branches located in the four different anatomic regions of the lung were measured in two orthogonal planes. A patient with a solitary pulmonary nodule (SPN) underwent DCE-MRI utilizing a 2D spoiled gradient-echo (SPGR) sequence while the patient breathed shallowly and freely during the scan. The standard deviations of the excursion of the highest point and selected pulmonary vessels were much smaller during shallow, free breathing maneuver scans than those during breath hold maneuver scans. A dynamic perfusion-fitting curve of the SPN was obtained during the DCE-MRI using shallow free breathing. Shallow, free breathing allows smaller diaphragmatic cranial caudal and lung parenchymal displacements. Therefore, it can be useful during exams where targeting of the lesion is necessary, in studies with long scan times, such as dynamic MRI. This breathing maneuver makes it possible to analyze SPN with DCE-MRI while making use of the advantages of a higher magnetic field in conjunction.

  14. Contrast enhanced MR imaging of female pelvic cancers: Established methods and emerging applications

    Energy Technology Data Exchange (ETDEWEB)

    Punwani, Shonit, E-mail: shonit.punwani@gmail.com [Department of Academic Radiology, 2nd Floor Podium, University College London Hospital, 235 Euston Road, London NW1 2BU (United Kingdom)

    2011-04-15

    Contrast enhanced magnetic resonance imaging of female pelvic cancers has been established for over 20 years. Conventional contrast enhanced imaging involves acquiring a set of pre-contrast T1 weighted images, followed by intravenous injection of an gadolinium based contrast agent and subsequent acquisition of a second set of contrast enhanced images. Developments in MR hardware and pulse sequences over the last 10 years have made dynamic contrast enhanced (DCE) protocols possible. DCE-MRI entails imaging of the same volume repeatedly prior to, during and following contrast injection. There have also been developments in image analysis methods and tools to reflect the increased data acquired. Qualitative analysis of contrast enhanced imaging (whether a single set or temporal series) by radiologists remains the mainstay for clinical reporting. Semi-quantitative assessment of signal intensity versus time curves and full pharmacokinetic modelling methods have emerged for evaluation of DCE-MRI data. DCE-MRI has found an established role in the detection, localisation and staging of female pelvic malignancies. Emerging applications of DCE-MRI include assessment of tumour grade, histology prior to and following treatment and prediction of individual and final treatment outcome. This article reviews the biophysical basis of contrast enhancement, the technical aspects of performance and analysis of DCE-MRI studies, and the established and emerging clinical utility of DCE-MRI in female pelvic malignancies.

  15. Contrast enhancement of the cochlear aqueduct in MR imaging: its frequency and clinical significance

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, T.; Naganawa, S.; Fukatsu, H.; Sakurai, Y.; Ishigaki, T. [Department of Radiology, Nagoya University School of Medicine, 65 Tsurumai-cho, 466-8550, Shouwa-ku, Nagoya (Japan); Aoki, I.; Ninomiya, A. [Medical Systems Company, Toshiba Corporation, Nasu Operations, Otawara-shi, Tochigi (Japan); Nakashima, T. [Department of Otorhinolaryngology, Nagoya University School of Medicine, Shouwa-ku, Nagoya (Japan)

    2003-09-01

    There have been no previous reports on contrast enhancement of the cochlear aqueduct in magnetic resonance imaging. The purpose of the present study was to evaluate the frequency and significance of this finding. Thirty-one patients (15 men and 16 women; age range 18-81 years) with otologic symptoms (sudden sensorineural hearing loss, vertigo, or tinnitus) were examined using contrast-enhanced imaging on a 1.5-T MR scanner. The normal ear served as the control. Two radiologists evaluated contrast enhancement in the area of the cochlear aqueduct. Forty-eight of 62 ears (77.4%) showed contrast enhancement of the cochlear aqueduct, but no significant differences in the frequency of contrast enhancement were observed between patients with and patients without vertigo, tinnitus, sensorineural hearing loss, cerebellopontine angle tumors, or a high-riding jugular bulb. In addition, no gender- or age-related differences were noted. Contrast enhancement of the cochlear aqueduct was frequently observed, but the frequency of enhancement in symptomatic ears was not significantly higher than in control ears. The results of this study may prove helpful in avoiding unnecessary examinations and potential diagnostic confusion. (orig.)

  16. Gray-scale contrast-enhanced utrasonography in detecting sentinel lymph nodes: An animal study

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yuexiang, E-mail: wangyuexiang1999@sina.co [Department of Ultrasound, Chinese People' s Liberation Army General Hospital, 28 Fuxing Road, Beijing 100853 (China); Cheng Zhigang, E-mail: qlczg@sina.co [Department of Ultrasound, Chinese People' s Liberation Army General Hospital, 28 Fuxing Road, Beijing 100853 (China); Li Junlai, E-mail: junlai555@sina.co [Department of Ultrasound, Chinese People' s Liberation Army General Hospital, 28 Fuxing Road, Beijing 100853 (China); Tang Jie, E-mail: txiner@vip.sina.co [Department of Ultrasound, Chinese People' s Liberation Army General Hospital, 28 Fuxing Road, Beijing 100853 (China)

    2010-06-15

    Objective: To investigate the usefulness of gray-scale contrast-enhanced ultrasonography for detecting sentinel lymph nodes. Methods: Contrast-enhanced ultrasonography was performed in five normal dogs (four female and one male) after subcutaneous administration of a sonographic contrast agent (Sonovue, Bracco, Milan, Italy). Four distinct regions in each animal were examined. After contrast-enhanced ultrasonography, 0.8 ml of blue dye was injected into the same location as Sonovue and the sentinel lymph nodes were detected by surgical dissection. The findings of contrast-enhanced ultrasonography were compared with those of the blue dye. Results: Twenty-one sentinel lymph nodes were detected by contrast-enhanced ultrasonography while 23 were identified by blue dye with surgical dissection. Compared with the blue dye, the detection rate of enhanced ultrasonography for the sentinel lymph nodes is 91.3% (21/23). Two patterns of enhancement in the sentinel lymph nodes were observed: complete enhancement (5 sentinel lymph nodes) and partial enhancement (16 sentinel lymph nodes). The lymphatic channels were demonstrated as hyperechoic linear structures leading from the injection site and could be readily followed to their sentinel lymph nodes. Histopathologic examination showed proliferation of lymphatic follicles or lymphatic sinus in partial enhanced sentinel lymph nodes while normal lymphatic tissue was demonstrated in completely enhanced sentinel lymph nodes. Conclusions: Sonovue combined with gray-scale contrast-enhanced ultrasonography may provide a feasible method for detecting sentinel lymph nodes.

  17. A new hardware-efficient algorithm and reconfigurable architecture for image contrast enhancement.

    Science.gov (United States)

    Huang, Shih-Chia; Chen, Wen-Chieh

    2014-10-01

    Contrast enhancement is crucial when generating high quality images for image processing applications, such as digital image or video photography, liquid crystal display processing, and medical image analysis. In order to achieve real-time performance for high-definition video applications, it is necessary to design efficient contrast enhancement hardware architecture to meet the needs of real-time processing. In this paper, we propose a novel hardware-oriented contrast enhancement algorithm which can be implemented effectively for hardware design. In order to be considered for hardware implementation, approximation techniques are proposed to reduce these complex computations during performance of the contrast enhancement algorithm. The proposed hardware-oriented contrast enhancement algorithm achieves good image quality by measuring the results of qualitative and quantitative analyzes. To decrease hardware cost and improve hardware utilization for real-time performance, a reduction in circuit area is proposed through use of parameter-controlled reconfigurable architecture. The experiment results show that the proposed hardware-oriented contrast enhancement algorithm can provide an average frame rate of 48.23 frames/s at high definition resolution 1920 × 1080.

  18. Non-contrast-enhanced pulmonary vein MRI with a spatially selective slab inversion preparation sequence.

    Science.gov (United States)

    Hu, Peng; Chuang, Michael L; Kissinger, Kraig V; Goddu, Beth; Goepfert, Lois A; Rofsky, Neil M; Manning, Warren J; Nezafat, Reza

    2010-02-01

    We propose a non-contrast-enhanced, three-dimensional, free-breathing, electrocardiogram-gated, gradient recalled echo sequence with a slab-selective inversion for pulmonary vein (PV) MRI. A sagittal inversion slab was applied prior to data acquisition to suppress structures adjacent to the left atrium (LA) and PVs, thereby improving the conspicuity of the PV and LA. Compared with other MR angiography methods using an inversion pulse, the proposed method does not require signal subtraction and the inversion slab is not parallel to the imaging slab. The feasibility of the proposed method was demonstrated in healthy subjects. The inversion slab thickness and inversion time were optimized to be 60 mm and 500 ms, respectively. Compared to conventional gradient recalled echo imaging without inversion, the proposed technique significantly increased the contrast-to-noise ratios between the LA and the right atrium by 20-fold (P slab (P > 0.3). The proposed technique greatly enhances the conspicuity of the PVs and LA without significant loss of signal-to-noise ratio.

  19. Oral contrast-enhanced three-dimensional helical-CT cholangiography: clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Stabile Ianora, Amato Antonio; Memeo, Maurizio; Scardapane, Arnaldo; Rotondo, Antonio; Angelelli, Giuseppe [Department of Radiology, University Hospital-Policlinico of Bari, Piazza Giulio Cesare 11, 70124 Bari (Italy)

    2003-04-01

    Our objective was to define the possibility of using oral-contrast-enhanced helical CT for the assessment of patients with cholecystolithiasis and of cholecystectomized symptomatic patients. Twenty-seven patients with cholecystolithiasis and 20 with a painful abdominal symptomatology after cholecystectomy (12 laparoscopic and 8 laparotomic) were recruited for this study. Cholangio-CT was performed 12-14 h after oral administration of 6 g of hyopanoic acid. The acquired data were then transferred to a second workstation and 3D reconstruction of the biliary tract was obtained. In all the cases the extrahepatic bile ducts were recognizable. Seven patients had no gallbladder opacification: CT images showed in 3 cases an infundibular stone and in 4 cases sclero-atrophic gallbladder. The intrahepatic bile ducts were visible in 21 of 27 patients with lithiasis and in 14 of 20 cholecystectomized patients. In 5 cholecystectomized patients cholangio-CT demonstrated the presence of residual choledochal or intrahepatic stones. In 3 cholecystectomized patients 3D reconstruction allowed identification of a long and winding stump of the cystic duct. Cholangio-CT is a non-invasive method to evaluate the biliary tract in patients who cannot be subjected to cholangio-MR, or as a preliminary to endoscopic retrograde cholangiopancreatography in cases of doubtful diagnosis after US and cholangio-MR. (orig.)

  20. Contrast-enhanced optical coherence tomography with picomolar sensitivity for functional in vivo imaging

    Science.gov (United States)

    Liba, Orly; Sorelle, Elliott D.; Sen, Debasish; de La Zerda, Adam

    2016-03-01

    Optical Coherence Tomography (OCT) enables real-time imaging of living tissues at cell-scale resolution over millimeters in three dimensions. Despite these advantages, functional biological studies with OCT have been limited by a lack of exogenous contrast agents that can be distinguished from tissue. Here we report an approach to functional OCT imaging that implements custom algorithms to spectrally identify unique contrast agents: large gold nanorods (LGNRs). LGNRs exhibit 110-fold greater spectral signal per particle than conventional GNRs, which enables detection of individual LGNRs in water and concentrations as low as 250 pM in the circulation of living mice. This translates to ~40 particles per imaging voxel in vivo. Unlike previous implementations of OCT spectral detection, the methods described herein adaptively compensate for depth and processing artifacts on a per sample basis. Collectively, these methods enable high-quality noninvasive contrast-enhanced imaging of OCT in living subjects, including detection of tumor microvasculature at twice the depth achievable with conventional OCT. Additionally, multiplexed detection of spectrally-distinct LGNRs was demonstrated to observe discrete patterns of lymphatic drainage and identify individual lymphangions and lymphatic valve functional states. These capabilities provide a powerful platform for molecular imaging and characterization of tissue noninvasively at cellular resolution, called MOZART.

  1. Role of contrast-enhanced MR venography in the preoperative evaluation of parasagittal meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Bozzao, Alessandro; Finocchi, Vanina; Romano, Andrea; Ferrante, Michele; Fasoli, Fabrizio; Fantozzi, Luigi Maria [S. Andrea Hospital, Neuroradiological Section, Rome (Italy); Trillo, Giuseppe; Ferrante, Luigi [S. Andrea Hospital, Neurosurgical Section, Rome (Italy)

    2005-09-01

    Parasagittal meningiomas (PSM) may pose a difficult surgical challenge since venous patency and collateral anastomoses have to be clearly defined for correct surgical planning. The aim of this study was to assess the diagnostic value of contrast-enhanced (CE) magnetic resonance venography (MRV) in the preoperative evaluation of venous infiltration and collateral venous anastomoses in patients with PSM. CE-MRV was compared with phase-contrast (PC) magnetic resonance (MR) angiography, conventional angiography (when available), and surgery as a reference. Twenty-three patients undergoing surgery for meningiomas located adjacent to the superior sagittal sinus were prospectively evaluated. All the patients underwent both conventional MR examination and MRV. This was performed by means of PC and CE techniques. Both sets of angiograms (CE and PC) were evaluated by two expert neuroradiologists to assess (1) patency of the sinus (patent/occluded), (2) the extent of occlusion (in centimeters), and (3) the number of collateral anastomoses close to the insertion of the meningioma. Eight patients underwent digital subtraction angiography (DSA). All patients were operated on, and intraoperative findings were taken as the gold standard to evaluate the diagnostic value of MRA techniques. PC-MRV showed a flow void inside the sinus compatible with its occlusion in 15 cases, whereas CE-MRV showed the sinus to be occluded in five cases. CE-MRV data were confirmed by surgery, showing five patients to have an occlusion of the superior sagittal sinus. The PC-MRV sensitivity was thus 100% with a specificity of 50%. In those cases in which both MRV techniques documented occlusion of the sinus, the extent of occlusion was overestimated by PC compared with CE and surgery. CE-MRV depicted 87% of collateral venous anastomoses close to the meningioma as subsequently confirmed by surgery, while PC showed 58%. In the preoperative planning for patients with meningiomas located close to a venous

  2. Can contrast-enhanced ultrasonography replace multidetector-computed tomography in the detection of liver metastases from colorectal cancer?

    DEFF Research Database (Denmark)

    Larsen, Lars P.S.; Rosenkilde, Mona; Christensen, Henrik

    2007-01-01

    consecutive patients referred to the Department of Colorectal Surgery, Aarhus University Hospital with primary or local recurrence of CRC. The patients underwent liver ultrasonography (US), CEUS, MDCT and intraoperative ultrasonography (IOUS). Fine-needle biopsy was performed on all suspicious lesions......PURPOSE: To compare the sensitivity and specificity of contrast-enhanced ultrasonography (CEUS) and 4-slice multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer (CRC). MATERIALS AND METHODS: Candidates for this prospective study were 461....... The examinations were interpreted blindly and the combination of US, CEUS, biphasic MDCT, IOUS, follow up and biopsy was the gold standard. RESULTS: Three hundred and sixty-five patients were included. All patients had undergone preoperative US, CEUS and MDCT and 65.5% had received IOUS. The gold standard found...

  3. Assessment of the link between quantitative biexponential diffusion-weighted imaging and contrast-enhanced MRI in the liver.

    Science.gov (United States)

    Dijkstra, Hildebrand; Oudkerk, Matthijs; Kappert, Peter; Sijens, Paul E

    2017-05-01

    To investigate if intravoxel incoherent motion (IVIM) modeled diffusion-weighted imaging (DWI) can be linked to contrast-enhanced (CE-)MRI in liver parenchyma and liver lesions. Twenty-five patients underwent IVIM-DWI followed by multiphase CE-MRI using Gd-EOB-DTPA (n=20) or Gd-DOTA (n=5) concluded with IVIM-DWI. Diffusion (Dslow), microperfusion (Dfast), its fraction (ffast), wash-in-rate (Rearly) and late-enhancement-rate (Rlate) of Gd-EOB-DTPA were calculated voxel-wise for the liver. Parenchyma and lesions were segmented. Pre-contrast IVIM was compared 1) between low, medium and high Rearly for parenchyma 2) to post-contrast IVIM substantiated with simulations 3) between low and high Rlate per lesion type. Dfast and ffast increased (Pquantitative liver imaging. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Effects of noradrenaline and adenosine triphosphate on the degree on contrast enhancement in a rabbit model of atherosclerosis during contrast-enhanced ultrasonography.

    Science.gov (United States)

    Sun, Jie; Deng, You-Bin; Liu, Kun; Wang, Yu-Bo

    2014-11-01

    The aim of the study is to assess the effects of vasoactive agents on the degree of contrast enhancement in experimental atherosclerotic plaque during contrast-enhanced ultrasonography (CEUS). Abdominal aortic atherosclerosis was induced in 25 New Zealand white rabbits by a combination of cholesterol-rich diet and balloon endothelial denudation. Standard ultrasonography and CEUS were performed at baseline and during intravenous infusion of noradrenaline or adenosine triphosphate (ATP). The degree of contrast enhancement of the plaque after injection of contrast material was quantified by calculating the enhanced intensity in the plaque. The infusion of noradrenaline induced significant increase in systolic blood pressure (84 ± 13 mm Hg vs. 112 ± 20 mm Hg, p = 0.011) and significant decrease in the enhanced intensity in the plaque (7.52 ± 1.32 dB vs. 5.88 ± 1.33 dB, p < 0.001) during CEUS. The infusion of ATP resulted in the significant decrease in systolic blood pressure (80 ± 13 mm Hg vs. 65 ± 11 mm Hg, p = 0.005) and increase in the enhanced intensity in the plaque (7.52 ± 1.32 dB vs. 8.84 ± 1.55 dB, p < 0.001) during CEUS. The degree of contrast enhancement within an experimental atherosclerotic plaque during CEUS can be influenced by vasoactive agents and hemodynamic status. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Contrast-Enhancement of the Anterior Eye Segment in Patients with Retinoblastoma: Correlation between Clinical, MR Imaging, and Histopathologic Findings

    NARCIS (Netherlands)

    de Graaf, P.; van der Valk, P.; Moll, A. C.; Imhof, S. M.; Schouten-van Meeteren, A. Y. N.; Knol, D. L.; Castelijns, J. A.

    2010-01-01

    BACKGROUND AND PURPOSE: AES contrast-enhancement is recognized in a substantial number of retinoblastoma-affected eyes. We retrospectively investigated the histopathologic basis of AES contrast-enhancement on MR images in retinoblastoma. MATERIALS AND METHODS: Pretreatment contrast-enhanced MR

  6. Delayed contrast enhancement imaging of a murine model for ischemia reperfusion with carbon nanotube micro-CT.

    Directory of Open Access Journals (Sweden)

    Laurel M Burk

    Full Text Available We aim to demonstrate the application of free-breathing prospectively gated carbon nanotube (CNT micro-CT by evaluating a myocardial infarction model with a delayed contrast enhancement technique. Evaluation of murine cardiac models using micro-CT imaging has historically been limited by extreme imaging requirements. Newly-developed CNT-based x-ray sources offer precise temporal resolution, allowing elimination of physiological motion through prospective gating. Using free-breathing, cardiac-gated CNT micro-CT, a myocardial infarction model can be studied non-invasively and with high resolution. Myocardial infarction was induced in eight male C57BL/6 mice aged 8-12 weeks. The ischemia reperfusion model was achieved by surgically occluding the LAD artery for 30 minutes followed by 24 hours of reperfusion. Tail vein catheters were placed for contrast administration. Iohexol 300 mgI/mL was administered followed by images obtained in diastole. Iodinated lipid blood pool contrast agent was then administered, followed with images at systole and diastole. Respiratory and cardiac signals were monitored externally and used to gate the scans of free-breathing subjects. Seven control animals were scanned using the same imaging protocol. After imaging, the heart was harvested, cut into 1mm slices and stained with TTC. Post-processing analysis was performed using ITK-Snap and MATLAB. All animals demonstrated obvious delayed contrast enhancement in the left ventricular wall following the Iohexol injection. The blood pool contrast agent revealed significant changes in cardiac function quantified by 3-D volume ejection fractions. All subjects demonstrated areas of myocardial infarct in the LAD distribution on both TTC staining and micro-CT imaging. The CNT micro-CT system aids straightforward, free-breathing, prospectively-gated 3-D murine cardiac imaging. Delayed contrast enhancement allows identification of infarcted myocardium after a myocardial ischemic

  7. The added value of {sup 68}Ga-DOTA-TATE-PET to contrast-enhanced CT for primary site detection in CUP of neuroendocrine origin

    Energy Technology Data Exchange (ETDEWEB)

    Kazmierczak, Philipp M. [Klinikum der Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Muenchen (Germany); Rominger, Axel; Wenter, Vera [Ludwig-Maximilians-University Hospital Munich, Department of Nuclear Medicine, Muenchen (Germany); Spitzweg, Christine; Auernhammer, Christoph [Ludwig-Maximilians-University Hospital Munich, Department of Internal Medicine II, Muenchen (Germany); Angele, Martin K. [Ludwig-Maximilians-University Hospital Munich, Department of General, Visceral, Transplantation, Vascular and Thoracic Surgery, Muenchen (Germany); Rist, Carsten; Cyran, Clemens C. [Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Muenchen (Germany)

    2017-04-15

    To quantify the additional value of {sup 68}Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced {sup 68}Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and {sup 68}Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up {sup 68}Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p < 0.001). {sup 68}Ga-DOTA-TATE PET demonstrated a significantly higher sensitivity (94 % vs. 63 %, p = 0.005) and a significantly higher accuracy (87 % vs. 68 %, p = 0.003) than contrast-enhanced CT. Ga-DOTA-TATE PET/CT compared with contrast-enhanced CT alone provides an improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. (orig.)

  8. The added value of (68)Ga-DOTA-TATE-PET to contrast-enhanced CT for primary site detection in CUP of neuroendocrine origin.

    Science.gov (United States)

    Kazmierczak, Philipp M; Rominger, Axel; Wenter, Vera; Spitzweg, Christine; Auernhammer, Christoph; Angele, Martin K; Rist, Carsten; Cyran, Clemens C

    2017-04-01

    To quantify the additional value of (68)Ga-DOTA-TATE PET/CT in comparison with contrast-enhanced CT alone for primary tumour detection in neuroendocrine cancer of unknown primary (CUP-NET). In total, 38 consecutive patients (27 men, 11 women; mean age 62 years) with histologically proven CUP-NET who underwent a contrast-enhanced (68)Ga-DOTA-TATE PET/CT scan for primary tumour detection and staging between 2010 and 2014 were included in this IRB-approved retrospective study. Two blinded readers independently analysed the contrast-enhanced CT and (68)Ga-DOTA-TATE PET datasets separately and noted from which modality they suspected a primary tumour. Consensus was reached if the results were divergent. Postoperative histopathology (24 patients) and follow-up (68)Ga-DOTA-TATE PET/CT imaging (14 patients) served as the reference standards and statistical measures of diagnostic accuracy were calculated accordingly. The majority of confirmed primary tumours were located in the abdomen (ileum in 19 patients, pancreas in 12, lung in 2, small pelvis in 1). High interobserver agreement was noted regarding the suspected primary tumour site (Cohen's k 0.90, p improvement in sensitivity of 50 % and an improvement in accuracy of 30 % in primary tumour detection in CUP-NET. • (68)Ga-DOTA-TATE PET augments the sensitivity of contrast-enhanced CT by 50 % • (68)Ga-DOTA-TATE PET augments the accuracy of contrast-enhanced CT by 30 % • Somatostatin receptor-targeted hybrid imaging optimizes primary tumour detection in CUP-NET.

  9. Linearization improves the repeatability of quantitative dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Jones, Kyle M; Pagel, Mark D; Cárdenas-Rodríguez, Julio

    2017-11-15

    The purpose of this study was to compare the repeatabilities of the linear and nonlinear Tofts and reference region models (RRM) for dynamic contrast-enhanced MRI (DCE-MRI). Simulated and experimental DCE-MRI data from 12 rats with a flank tumor of C6 glioma acquired over three consecutive days were analyzed using four quantitative and semi-quantitative DCE-MRI metrics. The quantitative methods used were: 1) linear Tofts model (LTM), 2) non-linear Tofts model (NTM), 3) linear RRM (LRRM), and 4) non-linear RRM (NRRM). The following semi-quantitative metrics were used: 1) maximum enhancement ratio (MER), 2) time to peak (TTP), 3) initial area under the curve (iauc64), and 4) slope. LTM and NTM were used to estimate K(trans), while LRRM and NRRM were used to estimate K(trans) relative to muscle (R(Ktrans)). Repeatability was assessed by calculating the within-subject coefficient of variation (wSCV) and the percent intra-subject variation (iSV) determined with the Gage R&R analysis. The iSV for R(Ktrans) using LRRM was two-fold lower compared to NRRM at all simulated and experimental conditions. A similar trend was observed for the Tofts model, where LTM was at least 50% more repeatable than the NTM under all experimental and simulated conditions. The semi-quantitative metrics iauc64 and MER were as equally repeatable as K(trans) and R(Ktrans) estimated by LTM and LRRM respectively. The iSV for iauc64 and MER were significantly lower than the iSV for slope and TTP. In simulations and experimental results, linearization improves the repeatability of quantitative DCE-MRI by at least 30%, making it as repeatable as semi-quantitative metrics. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Contrast-Enhanced Ultrasound Reveals Exercise-Induced Perfusion Deficits in Claudicants.

    Science.gov (United States)

    Kundi, Rishi; Prior, Steven J; Addison, Odessa; Lu, Michael; Ryan, Alice S; Lal, Brajesh K

    2017-01-01

    Contrast-Enhanced Ultrasonography (CEUS) is an imaging modality allowing perfusion quantification in targeted regions of interest of the lower extremity that has not been possible with color-flow imaging or with measurement of ankle brachial indices. We developed a protocol to quantify lower extremity muscle perfusion impairment in PAD patients in response to exercise. Thirteen patients with Rutherford Class I-III Peripheral Arterial Disease (PAD) and no prior revascularization procedures were recruited from the Baltimore Veterans Affairs Medical Center and compared with eight control patients without PAD. CEUS interrogation of the index limb gastrocnemius muscle was performed using an intravenous bolus of lipid-stabilized microsphere contrast before and after a standardized treadmill protocol. Peak perfusion (PEAK) and time to peak perfusion (TTP) were measured before and after exercise. Between and within group differences were assessed. Control subjects demonstrated a more rapid TTP (p<0.01) and an increase in peak perfusion (PEAK, p=0.02) after exercise, when compared to their baseline measures. Patients with PAD demonstrated TTP and PEAK measures equivalent to controls at baseline (p=0.39, p=0.71, respectively). However, they exhibited no significant exercise-induced changes in perfusion (TTP p=0.49 and PEAK 0.67, respectively compared to baseline). After exercise, normal subjects had significantly shorter TTP (p=0.04) and greater PEAK (p=0.02) than PAD patients. Consistent with their lack of ischemic symptoms at rest, class I to III claudicant PAD patients showed similar perfusion measures (TTP and PEAK) at rest. PAD patients, however, were unable to increase perfusion in response to exercise, whereas controls increased perfusion significantly. This corresponds with claudication and limited walking capacity observed in PAD. CEUS with bolus injection offers a convenient, objective, quantitative and visual physiologic assessment of perfusion limitation in

  11. Comparison of dynamic contrast-enhanced magnetic resonance imaging with T2-weighted imaging for preoperative staging of early endometrial carcinoma

    Directory of Open Access Journals (Sweden)

    Zheng L

    2015-07-01

    Full Text Available Linfeng Zheng,1,2 Sujuan Zheng,3 Xiaochun Yuan,1 Xifu Wang,1 Zhuoli Zhang,2 Guixiang Zhang1 1Department of Radiology, Shanghai First People’s Hospital, Shanghai Jiao Tong University, Shanghai, People’s Republic of China; 2Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA; 3Department of Obstetrics and Gynecology, Dengfeng People’s Hospital, Zhengzhou, People’s Republic of China Purpose: This study aimed to compare dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI with T2-weighted imaging (T2WI for the preoperative staging of early endometrial carcinoma. Methods: This retrospective study included 22 subjects with early endometrial carcinoma who underwent 3.0 T MRI examination prior to hysterectomy. DCE-MRI and T2WI were evaluated for the preoperative staging of endometrial carcinoma. The sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and accuracy of DCE-MRI and T2WI were assessed and compared using the revised International Federation of Gynecology and Obstetrics surgical staging guidelines (2009 as the reference standard. Results: Out of the 22 cases of endometrial carcinoma, the use of the reference standard method led to the staging of 14 as IA and eight as IB. The sensitivity, specificity, PPV, NPV, and accuracy of DCE-MRI for preoperative staging were 100% (95% confidence interval: 0.73–1.0, 62.5% (95% CI: 0.26–0.90, 82.4% (95% CI: 0.56–0.95, 100% (95% CI: 0.46–1.0, and 86.4%, respectively, and these values were 85.7% (95% CI: 0.56–0.97, 75% (95% CI: 0.36–0.96, 85.7% (95% CI: 0.56–0.97, 75% (95% CI: 0.36–0.96, and 81.8%, respectively, for T2WI. Thus, the sensitivity and accuracy of DCE-MRI were greater than those of T2WI for preoperative endometrial carcinoma staging. Conclusion: DCE-MRI was more sensitive but less specific than T2WI for the preoperative staging of early endometrial carcinoma. DCE-MRI may serve as a

  12. A comparative study on preprocessing techniques in diabetic retinopathy retinal images: illumination correction and contrast enhancement.

    Science.gov (United States)

    Rasta, Seyed Hossein; Partovi, Mahsa Eisazadeh; Seyedarabi, Hadi; Javadzadeh, Alireza

    2015-01-01

    To investigate the effect of preprocessing techniques including contrast enhancement and illumination correction on retinal image quality, a comparative study was carried out. We studied and implemented a few illumination correction and contrast enhancement techniques on color retinal images to find out the best technique for optimum image enhancement. To compare and choose the best illumination correction technique we analyzed the corrected red and green components of color retinal images statistically and visually. The two contrast enhancement techniques were analyzed using a vessel segmentation algorithm by calculating the sensitivity and specificity. The statistical evaluation of the illumination correction techniques were carried out by calculating the coefficients of variation. The dividing method using the median filter to estimate background illumination showed the lowest Coefficients of variations in the red component. The quotient and homomorphic filtering methods after the dividing method presented good results based on their low Coefficients of variations. The contrast limited adaptive histogram equalization increased the sensitivity of the vessel segmentation algorithm up to 5% in the same amount of accuracy. The contrast limited adaptive histogram equalization technique has a higher sensitivity than the polynomial transformation operator as a contrast enhancement technique for vessel segmentation. Three techniques including the dividing method using the median filter to estimate background, quotient based and homomorphic filtering were found as the effective illumination correction techniques based on a statistical evaluation. Applying the local contrast enhancement technique, such as CLAHE, for fundus images presented good potentials in enhancing the vasculature segmentation.

  13. Dynamic Contrast-Enhanced Magnetic Resonance Imaging Suggests Normal Perfusion in Normal-Appearing White Matter in Multiple Sclerosis.

    Science.gov (United States)

    Ingrisch, Michael; Sourbron, Steven; Herberich, Sina; Schneider, Moritz Jörg; Kümpfel, Tania; Hohlfeld, Reinhard; Reiser, Maximilian F; Ertl-Wagner, Birgit

    2017-03-01

    Multiple sclerosis (MS) is a chronic, inflammatory disease of the central nervous system and has been associated with reduced perfusion in normal-appearing white matter (NAWM). The magnitude of this hypoperfusion is unclear. The present study aims to quantify NAWM perfusion with dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) in patients with relapsing-remitting (RR) MS and in a control group. The statistical power of a DCE-MRI acquisition to reveal hypoperfusion in MS was estimated using a Monte Carlo simulation: synthetic tissue curves with a contrast-to-noise ratio of 8 were generated for MS patients and control group using perfusion values reported in previous studies. A compartment-uptake model was fitted to these curves, yielding estimates of cerebral blood flow (CBF), cerebral blood volume (CBV), and permeability-surface area product (PS). This was repeated 1000 times. Mean and standard deviation of the resulting distributions were used to calculate the statistical power of a DCE-MRI study to detect perfusion differences between 16 control subjects and 24 MS subjects.In an institutional review board-approved study, patients with RR-MS (n = 24; mean age, 36 years; 17 women, mean Enhanced Disability Status Scale score, 3.25) and patients without history or symptoms of neurological disorder (n = 16; mean age, 49 years; 9 women) underwent a DCE-MRI examination with a previously established MRI protocol (3D SPGR sequence; 2.1 seconds temporal resolution; 44 slices; spatial resolution, 1.7 × 1.7 × 3 mm). Regions were defined manually in the middle cerebral artery; in the frontal, periventricular, and occipital NAWM; in the pons; and in the thalamus, and CBF, CBV, and PS were quantified using a compartment-uptake model.Parameter differences between MS and control groups were evaluated using a mixed linear model with subjects as random effect and controlling for age and sex. A P value of less than 0.05 was considered to indicate statistical

  14. CT contrast enhancement following renal cryoablation – artefact or treatment failure?

    DEFF Research Database (Denmark)

    Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Andersen, Gratien

    Introduction and objective: Renal cryoablation is a valid treatment option for localized pT1a renal cancer. Treatment success is typically defined as absence of contrast enhancement (CE) and a decrease in size of the cryoablated renal mass (i.e. cryolesion) on follow-up imaging. We investigated...... (LCA) or percutaneous cryoablation (PCA) from August 2005 to August 2012 at Aarhus University Hospital. Six patients were excluded from analysis due to MRI follow-up. During routine postoperative CT follow-up, contrast enhancement of the cryolesion was identified in 34 of the 107 patients (32......, PADUA- score and level of contrast enhancement was significantly (penhancement pattern and number of cryoprobes used were not significantly different between the two groups. In patients where...

  15. Portal biliopathy diagnosed using color Doppler and contrast-enhanced ultrasound.

    Science.gov (United States)

    Nunoi, Hiroaki; Hirooka, Masashi; Ochi, Hironori; Koizumi, Yohei; Tokumoto, Yoshio; Abe, Masanori; Tada, Fujimasa; Ikeda, Yoshio; Matsuura, Bunzo; Tanaka, Hiroaki; Tsuda, Takaharu; Mochizuki, Teruhito; Hiasa, Yoichi; Onji, Morikazu

    2013-01-01

    Portal biliopathy is a morphological abnormality of the biliary ductal and gallbladder wall associated with portal hypertension. A patient with essential thrombocythemia was initially diagnosed with extrahepatic portal vein obstruction (EHPVO). The contrast-enhanced computed tomography (CT) findings were similar to those of cholangiocarcinoma or sclerosing cholangitis. However, color Doppler and contrast-enhanced ultrasound (US) were more specific. The paracholedocheal veins around the bile ducts appeared as beads soon after the injection of contrast medium, followed by linear enhancement of the epicholedochal veins and the gradual enhancement of the whole bile ducts. These findings led to a diagnosis of portal biliopathy, which prevented the patient from having to endure hazardous procedures such as bile duct biopsies. Color Doppler and contrast-enhanced US findings are useful for diagnosing or ruling out portal biliopathy in patients who present with EHPVO.

  16. The clinical use of contrast-enhanced ultrasound in the kidney.

    Science.gov (United States)

    Tenant, Sean C; Gutteridge, Catherine M

    2016-05-01

    Traditional B-Mode and Doppler sonography have been the stalwart of renal tract imaging for many years, and indeed, are in daily use in most centres as the modality of choice for the initial assessment of renal pathology. However, traditional ultrasound scanning can be limited in its ability to accurately characterise renal pathology, and can be inaccurate at determining benign from malignant lesions. Contrast-enhanced ultrasound conveys many benefits, being safe (especially in patients with renal dysfunction), does not require the use of ionising radiation, is quick and relatively cheap and can help to establish whether a focal renal lesion is sinister. Furthermore, it is our experience that contrast-enhanced ultrasound is not a difficult technique to master for the experienced ultrasound practitioner. In this article, we discuss the technique, interpretation and value of contrast-enhanced ultrasound in renal imaging, and describe how we use it in our practice.

  17. Management of Indeterminate Cystic Kidney Lesions: Review of Contrast-enhanced Ultrasound as a Diagnostic Tool.

    Science.gov (United States)

    Chang, Emily H; Chong, Wui K; Kasoji, Sandeep K; Dayton, Paul A; Rathmell, W Kimryn

    2016-01-01

    Indeterminate cystic kidney lesions found incidentally are an increasingly prevalent diagnostic challenge. Standard workup includes Bosniak classification with contrast-enhanced computed tomography (CT) or magnetic resonance imaging (MRI). However, these tests are costly and not without risks. Contrast-enhanced ultrasound (CEUS) is a relatively new technique with lower risk of adverse events than iodine-containing contrast or gadolinium. In our review of the evidence for characterization of cystic kidney lesions with CEUS, CEUS displayed sensitivity (89%-100%) and negative predictive value (86%-100%) comparable to contrast-enhanced CT or MRI, with no decrease in specificity compared with CT and only a slight decrease compared with MRI. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. [Properties of gas (CO2) microbubbles made by hand agitation and it's contrast enhancing effect].

    Science.gov (United States)

    Matsuda, Y; Yabuuchi, I; Ito, T

    1998-04-01

    The property of gas (CO2) microbubbles made by hand agitation and it's contrast enhancing effect of abdominal organs on gray scale ultrasound are here described. The size of microbubbles of CO2 gas adequately prepared with 5% human serum albumin was nearly 23 microns in mean diameter. However, the size and the density of gas microbubbles are affected with many factors, including mixing times, volume ratio of gas and liquid and the species of gas and liquid. On the other hand, contrast enhancing effect is determined by the size and the density of gas microbubbles. For the adequate evaluation of contrast enhancing effect of abdominal tumors by enhanced ultrasonography, the property of gas microbubbles described as above should be carefully considered.

  19. Improved detection of hepatic metastases with contrast-enhanced low mechanical-index pulse inversion ultrasonography during the liver-specific phase of sonazoid: observer performance study with JAFROC analysis.

    Science.gov (United States)

    Sugimoto, Katsutoshi; Shiraishi, Junji; Moriyasu, Fuminori; Saito, Kazuhiro; Doi, Kunio

    2009-07-01

    To compare B-mode ultrasonography (US) alone with the combination of B-mode and contrast-enhanced (Sonazoid) late-phase pulse-inversion US for the detection of hepatic metastases by use of jackknife free-response receiver-operating characteristic (JAFROC) analysis. Twenty-seven patients with 57 hepatic metastases and 6 patients without hepatic metastases underwent B-mode and contrast-enhanced US. We used the diagnoses established by contrast-enhanced computed tomography and contrast-enhanced US as the standard of reference. All ultrasonographic scanning was performed by an experienced radiologist with a routine clinical procedure. All scanning data were archived with digital cine clips. A review system, which can display pairs of cine clips for B-mode and contrast-enhanced US side by side, was developed for off-site observer study. Seven radiologists interpreted each case individually first by B-mode US only, and then by the combination with contrast-enhanced US by identifying locations of possible candidates for hepatic metastasis with their confidence ratings. The figure-of-merit (FOM) values, sensitivity, and false-positives per case were estimated for B-mode US alone, and for the combination of B-mode and contrast-enhanced US. The sensitivities of the combined ultrasonographic imaging (mean, 72.2%) were clearly improved from that of B-mode US alone (mean, 41.6%) while reducing the average number of false positives from 1.1 to 0.5 per case. In the jackknife analysis, there was a statistically significant difference between mean FOM values for the combined imaging (0.76) and for B-mode US alone (0.44, P cine clips of contrast-enhanced liver US together with B-mode US could improve physicians' accuracy for detection of hepatic metastases.

  20. Assessment of blood–brain barrier disruption using dynamic contrast-enhanced MRI. A systematic review

    Directory of Open Access Journals (Sweden)

    Anna K. Heye

    2014-01-01

    Full Text Available There is increasing recognition of the importance of blood–brain barrier (BBB disruption in aging, dementia, stroke and multiple sclerosis in addition to more commonly-studied pathologies such as tumors. Dynamic contrast-enhanced MRI (DCE-MRI is a method for studying BBB disruption in vivo. We review pathologies studied, scanning protocols and data analysis procedures to determine the range of available methods and their suitability to different pathologies. We systematically review the existing literature up to February 2014, seeking studies that assessed BBB integrity using T1-weighted DCE-MRI techniques in animals and humans in normal or abnormal brain tissues. The literature search provided 70 studies that were eligible for inclusion, involving 417 animals and 1564 human subjects in total. The pathologies most studied are intracranial neoplasms and acute ischemic strokes. There are large variations in the type of DCE-MRI sequence, the imaging protocols and the contrast agents used. Moreover, studies use a variety of different methods for data analysis, mainly based on model-free measurements and on the Patlak and Tofts models. Consequently, estimated KTrans values varied widely. In conclusion, DCE-MRI is shown to provide valuable information in a large variety of applications, ranging from common applications, such as grading of primary brain tumors, to more recent applications, such as assessment of subtle BBB dysfunction in Alzheimer's disease. Further research is required in order to establish consensus-based recommendations for data acquisition and analysis and, hence, improve inter-study comparability and promote wider use of DCE-MRI.

  1. Automatic motion estimation using flow parameters for dynamic contrast-enhanced ultrasound

    Science.gov (United States)

    Barrois, Guillaume; Coron, Alain; Lucidarme, Olivier; Bridal, S. Lori

    2015-03-01

    Dynamic contrast-enhanced ultrasound (DCE-US) sequences are subject to motion which can disturb functional flow quantification. This can make estimated parameters more variable or unreliable. Methods that compensate for motion are therefore desirable. The most commonly used motion correction techniques in DCE-US register the images in the sequence with respect to a user-selected reference image. However, this image may not include all features that are representative of the whole sequence. Moreover, image-based registration neglects pertinent, functional-flow information contained in the DCE-US sequence. An operator-free method is proposed that combines the motion estimation and flow-parameter quantification (M/Q method) in a single mathematical framework. This method is based on a realistic multiplicative model of the DCE-US noise. By computing likelihood in this model, motion and flow parameters are both estimated iteratively. First, the maximization is accomplished by estimating functional and motion parameters. Then, a final registration based on a non-parametric temporal smoothing of the sequence is performed. This method is compared to a conventional (mutual information) registration method where all the images of the sequence are registered with respect to a reference image chosen by an expert. The two methods are evaluated on simulated sequences and DCE-US sequences acquired in patients (N = 15). The M/Q method demonstrates significantly (p < 0.05) lower Dice coefficients and Hausdorff distance than the conventional method on the simulated data sets. On the in vivo sequences analysed, the M/Q methods outperformed the conventional method in terms of mean Dice and Hausdorff distance on 80% of the sequences, and in terms of standard deviation of Dice and Hausdorff distance on 87% of the sequences.

  2. [Value of contrast-enhanced MR enterography in pediatric Crohn's disease: preliminary study].

    Science.gov (United States)

    Godefroy, C; Pilleul, F; Dugougeat, F; Yzèbe, D; Lachaux, A; Pracros, J P; Valette, P J

    2005-11-01

    Feasibility study of contrast enhanced MR enterography without enteroclysis as a new diagnostic tool for children with known or suspected Crohn's disease. We prospectively included 15 children, 8-18 years old, with clinical suspicion of Crohn's disease. MR enterography without enteroclysis was performed on a 1,5 T clinical MR system. A total of 1000 ml of mannitol 5% was orally administered 60 minutes prior to MRI. Coronal and axial breath-hold sequences were acquired. The following sequences were obtained: True-FISP, FLASH T1 2D/3D with Fat saturation before and after gadolinium injection. Two radiologists, blinded to patient information, independently reviewed all examinations to record image quality, the degree of distension of the distal ileum, the presence of abnormal bowel segments and the presence of extra-intestinal complications. MRI findings were correlated to sonographic, endoscopic and biological results (sensitivity, specificity, Kappa test). The examinations were considered of satisfactory diagnostic quality in 93.3% of patients. Respiratory artifacts were present in one case. The entire GI tract could be identified on all sequences. Distention of the distal ileum was recorded as good to excellent in 89% of healthy subjects. Five MR examinations were considered abnormal with isolated ileal involvement in 2 cases, ileocolic involvement in 2 cases, and isolated colonic involvement in 1 case. The sensitivity and specificity of MR for the positive diagnosis of Crohn's disease were 100% and 83% respectively. Three extra-intestinal complications were detected: one case of ileo-ileal fistula, not identified on ultrasonography, an asymptomatic anal fistula and a symptomatic inflammatory stricture. MR enterography without enteroclysis is a well tolerated, effective non invasive method in the evaluation of known or suspected Crohn's disease. Because of the absence of ionizing radiation, MR enterography should become the gold standard in pediatric patients.

  3. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced

  4. Subtraction MR venography acquired from time-resolved contrast-enhanced MR angiography: Comparison with phase-contrast MR venography and single-phase contrast-enhanced MR venography

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jin Hee; Kim, Bum Soo; KIm, Bom Yi; Choi, Hyun Seok; Jung, So Lyung; Ahn, Kook Jin [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Sung, Ji Kyeong [Dept. of Radiology, St. Vincent' s Hospital, College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of)

    2015-12-15

    To evaluate the image characteristics of subtraction magnetic resonance venography (SMRV) from time-resolved contrast-enhanced MR angiography (TRMRA) compared with phase-contrast MR venography (PCMRV) and single-phase contrast-enhanced MR venography (CEMRV). Twenty-one patients who underwent brain MR venography (MRV) using standard protocols (PCMRV, CEMRV, and TRMRA) were included. SMRV was made by subtracting the arterial phase data from the venous phase data in TRMRA. Co-registration and subtraction of the two volume data was done using commercially available software. Image quality and the degree of arterial contamination of the three MRVs were compared. In the three MRVs, 19 pre-defined venous structures (14 dural sinuses and 5 cerebral veins) were evaluated. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the three MRVs were also compared. Single-phase contrast-enhanced MR venography showed better image quality (median score 4 in both reviewers) than did the other two MRVs (p < 0.001), whereas SMRV (median score 3 in both reviewers) and PCMRV (median score 3 in both reviewers) had similar image quality (p ≥ 0.951). SMRV (median score 0 in both reviewers) suppressed arterial signal better than did the other MRVs (median score 1 in CEMRV, median score 2 in PCMRV, both reviewers) (p < 0.001). The dural sinus score of SMRV (median and interquartile range [IQR] 48, 43-50 for reviewer 1, 47, 43-49 for reviewer 2) was significantly higher than for PCMRV (median and IQR 31, 25-34 for reviewer 1, 30, 23-32 for reviewer 2) (p < 0.01) and did not differ from that of CEMRV (median and IQR 50, 47-52 for reviewer 1, 49, 45-51 for reviewer 2) (p = 0.146 in reviewer 1 and 0.123 in reviewer 2). The SNR and CNR of SMRV (median and IQR 104.5, 83.1-121.2 and 104.1, 74.9-120.5, respectively) were between those of CEMRV (median and IQR 150.3, 111-182.6 and 148.4, 108-178.2) and PCMRV (median and IQR 59.4, 49.2-74.9 and 53.6, 43.8-69.2). Subtraction magnetic

  5. Hepatic blood perfusion estimated by dynamic contrast-enhanced computed tomography in pigs

    DEFF Research Database (Denmark)

    Winterdahl, Michael; Sørensen, Michael; Keiding, Inger Susanne

    2012-01-01

    The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates.......The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates....

  6. Contrast Enhancement on CT Following Renal Cryoablation – Does It Represent Treatment Failure?

    DEFF Research Database (Denmark)

    Nielsen, Tommy Kjærgaard; Østraat, Øyvind; Andersen, Gratien

    Aim: Renal cryoablation is a valid treatment option for localized pT1a renal cancer. Treatment success is typically defined as absence of contrast enhancement (CE) on follow-up imaging. We investigate the development of lesions that demonstrate CE on follow-up CT after renal cryoablation. Materials...... not uncommon. As there are no clear-cut criteria for monitoring treatment failure, careful evaluation by an experienced radiologist and urologist is recommend. The significance of delayed contrast enhancement is not clearly evident and needs further investigation....

  7. Indeterminate breast lesions: Can contrast enhanced digital mammography change our decisions?

    OpenAIRE

    Samira Saraya; Lamia Adel; Asmaa Mahmoud

    2017-01-01

    Objective: To assess the efficiency of dual energy contrast enhanced mammography in the assessment of the indeterminate breast lesions (BIRADS 3 and BIRADS 4). Materials and methods: 34 female having 39 indeterminate breast lesions (BIRADS 3 and BIRADS 4) by digital mammography were further examined by dual energy contrast enhanced mammography. Two images were acquired at low and high energy in MLO view after 2 min and in CC view at 4 min post iodinated contrast injection (1.5 ml/kg with f...

  8. Contrast-enhanced dual-energy mammography: a promising new imaging tool in breast cancer detection.

    Science.gov (United States)

    Lalji, Ulrich; Lobbes, Marc

    2014-05-01

    Contrast-enhanced dual-energy mammography (CEDM) is a promising new breast imaging tool for breast cancer detection. In CEDM, an iodine-based contrast agent is intravenously administered and subsequently, dual-energy mammography is performed. This results in a set of images containing both a regular mammogram and an image that contains contrast enhancement information. Preliminary studies have indicated that CEDM is superior to conventional mammography and might even match the diagnostic performance of breast MRI. In this review, the imaging technique, protocol and patient handling of CEDM is presented. Furthermore, an overview of current results on CEDM and potential future indications are outlined.

  9. Contrast-enhanced Digital Mammography: A Single-Institution Experience of the First 208 Cases.

    Science.gov (United States)

    Lewis, Tiffany C; Pizzitola, Victor J; Giurescu, Marina E; Eversman, William G; Lorans, Roxanne; Robinson, Kristin A; Patel, Bhavika K

    2017-01-01

    Contrast-enhanced digital mammography (CEDM) is the only imaging modality that provides both (a) a high-resolution, low-energy image comparable to that of digital mammography and (b) a contrast-enhanced image similar to that of magnetic resonance imaging. We report the initial 208 CEDM examinations performed for various clinical indications and provide illustrative case examples. Given its success in recent studies and our experience of CEDM primarily as a diagnostic adjunct, CEDM can potentially improve breast cancer detection by combining the low-cost conclusions of screening mammography with the high sensitivity of magnetic resonance imaging. © 2016 Wiley Periodicals, Inc.

  10. Breast lesion detection and characterization at contrast-enhanced MR mammography: gadobenate dimeglumine versus gadopentetate dimeglumine.

    Science.gov (United States)

    Pediconi, Federica; Catalano, Carlo; Occhiato, Rossella; Venditti, Fiammetta; Fraioli, Francesco; Napoli, Alessandro; Kirchin, Miles A; Passariello, Roberto

    2005-10-01

    To prospectively and intraindividually compare equivalent (0.1 mmol per kilogram of body weight) doses of gadobenate dimeglumine and gadopentetate dimeglumine for accuracy of detection and characterization of breast lesions at contrast material-enhanced magnetic resonance (MR) mammography. Ethics committee approval and informed consent were obtained. Twenty-six consecutive women (mean age, 47.8 years) suspected of having a breast tumor at mammography and sonography underwent two identical MR examinations at 1.5 T; examinations were separated by more than 48 hours but less than 72 hours. A T1-weighted three-dimensional gradient-echo sequence was used, and images were acquired before and at 0, 2, 4, 6, and 8 minutes after randomized injection of gadopentetate dimeglumine or gadobenate dimeglumine at an identical flow rate of 2 mL/sec. Separate and combined assessment of unenhanced, contrast-enhanced, and subtracted images was performed blindly by two readers in consensus. Accuracy for lesion detection was determined against a final diagnosis based on findings at conventional mammography, sonography, and surgery. Sensitivity, specificity, positive and negative predictive values, and overall accuracy for malignant lesion identification were determined against histologic results. Data were analyzed with the McNemar test, proportional odds models, and analysis of variance. MR mammography with gadobenate dimeglumine depicted significantly (P = .003) more lesions (45 of 46) than did that with gadopentetate dimeglumine (36 of 46), and detected lesions were significantly (P dimeglumine. Confidence for characterization was significantly (P = .031) greater with gadobenate dimeglumine. Comparison of the contrast agents for their ability to help identify malignant lesions revealed significant (P = .02) superiority for gadobenate dimeglumine: Sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy for malignant lesion identification

  11. Contrast-enhanced MR mammography: improved lesion detection and differentiation with gadobenate dimeglumine.

    Science.gov (United States)

    Pediconi, Federica; Catalano, Carlo; Padula, Simona; Roselli, Antonella; Dominelli, Valeria; Cagioli, Sabrina; Kirchin, Miles A; Pirovano, Gianpaolo; Passariello, Roberto

    2008-11-01

    The objective of our study was to intraindividually compare 0.1 mmol/kg doses of gadobenate dimeglumine and gadopentetate dimeglumine for contrast-enhanced breast MRI. Forty-seven women (mean age +/- SD, 50.8 +/- 12.9 years) with breast lesions classified as BI-RADS category 3, 4, or 5 for suspicion of malignancy underwent two identical MR examinations at 1.5 T separated by 48-72 hours. T1-weighted gradient-echo images were acquired before contrast administration and at 2-minute intervals after the randomized injection of gadopentetate dimeglumine or gadobenate dimeglumine at 2 mL/s. Two blinded readers evaluated randomized image sets for lesion detection and differentiation as benign or malignant compared with histology. The McNemar exact test and the generalized estimating equation (GEE) were used to compare lesion detection rates and diagnostic performance in terms of sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV). Histopathology data were available for 78 lesions. Significantly more lesions overall (75/78 [96%] vs 62/78 [79%], respectively; p = 0.0002) and significantly more malignant lesions (49/50 [98%] vs 38/50 [76%]; p = 0.0009) were detected with gadobenate dimeglumine than gadopentetate dimeglumine. All detected malignant lesions were correctly diagnosed with both agents. More detected benign lesions were correctly diagnosed with gadobenate dimeglumine than with gadopentetate dimeglumine (20/26 [77%] vs 17/24 [71%], respectively). Differentiation of lesions was significantly (p = 0.0001) better with gadobenate dimeglumine. Significantly better diagnostic performance was noted with gadobenate dimeglumine than with gadopentetate dimeglumine, respectively, for sensitivity (98.0% vs 76.0%; p = 0.0064), accuracy (88.5% vs 69.2%; p = 0.0004), PPV (86.0% vs 76.0%; p = 0.0321), and NPV (95.2% vs 57.1%; p = 0.0003). Lesion detection and malignant-benign differentiation is significantly better with 0.1 mmol

  12. Gender differences in contrast-enhanced magnetic resonance imaging after acute myocardial infarction.

    Science.gov (United States)

    Langhans, Birgit; Ibrahim, Tareq; Hausleiter, Jörg; Sonne, Carolin; Martinoff, Stefan; Schömig, Albert; Hadamitzky, Martin

    2013-03-01

    Besides different risk profiles for cardiovascular events in men and women, several studies reported gender differences in mortality after acute myocardial infarction (AMI). As infarct size has been shown to correlate with mortality, it is widely accepted as surrogate marker for clinical outcome. Currently, cardiovascular imaging studies covering the issue of gender differences are rare. As magnetic resonance scar characterization parameters are emerging as additional prognostic factors after acute myocardial infarction, we sought to evaluate gender differences in CMR infarct characteristics in patients after acute myocardial infarction. We prospectively analyzed patients (n = 448) with AMI and primary angioplasty, who underwent contrast-enhanced cardiac magnetic resonance (CMR) imaging on a 1.5 T scanner in median 5 [4, 6] days after the acute event. [corrected]. CMR scar size was measured 15 min after gadolinium injection. In addition presence and extent of microvascular obstruction (MVO) was assessed. A matched pair analysis was performed in order to exclude confounding by gender related co-morbidities and gender differences in established clinical risk factors. Matching process according to clinical risk defined by GRACE score resulted in 93 mixed gender couples. Women were significantly older than men (64.4 ± 11.9 vs. 60.5 ± 12.3, p = 0.03) and presented with a significantly better ejection fraction before angioplasty (48.9 ± 8.4 vs. 46.2 ± 8.9, p = 0.04). Infarct size did not differ significantly between women and men (13.5 ± 10.7 vs. 15.1 ± 11.8, p = 0.32). Size of MVO was significantly smaller in women than in men (0.48 ± 1.3 vs. 1.2 ± 3.0, p = 0.03). Comparing scar characterization between women and men with similar risk profiles revealed no gender differences in scar size. Size of MVO, however, was significantly smaller in women and might reflect better cardioprotective mechanisms in women. Whether these changes have prognostic implications has to

  13. Comparison between survey radiography, B-mode ultrasonography, contrast-enhanced ultrasonography and contrast-enhanced multi-detector computed tomography findings in dogs with acute abdominal signs.

    Science.gov (United States)

    Shanaman, Miriam M; Schwarz, Tobias; Gal, Arnon; O'Brien, Robert T

    2013-01-01

    Contrast-enhanced multi-detector computed tomography (CE-MDCT) is used routinely in evaluating human patients with acute abdominal symptoms. Contrast-enhanced ultrasound (CEUS) continues to be in its infancy as it relates to evaluation of the acute abdomen. The purpose of this study was to compare survey radiography, B-mode ultrasound, CEUS, and CE-MDCT findings in canine patients presenting with acute abdominal signs; with a focus on the ability to differentiate surgical from non-surgical conditions. Nineteen dogs were prospectively enrolled. Inclusion required a clinical diagnosis of acute abdominal signs and confirmed surgical or non-surgical causes for the clinical signs. Agreement for the majority of recorded imaging features was at least moderate. There was poor agreement in the identification of pneumoperitoneum and in the comparison of pancreatic lesion dimensions for B-mode vs. CEUS. The CT feature of fat stranding was detected in cases including, but not limited to, gastric neoplasia with perforation, pancreatitis, and small intestinal foreign body. Ultrasound underestimated the size and number of specific lesions when compared with CE-MDCT. Contrast-enhanced ultrasound was successful in detecting bowel and pancreatic perfusion deficits that CE-MDCT failed to identify. Accuracy for differentiation of surgical vs. non-surgical conditions was high for all modalities; 100%, 94%, and 94% for CE-MDCT, ultrasonography and survey radiography respectively. Findings indicated that CE-MDCT is an accurate screening test for differentiating surgical from non-surgical acute abdominal conditions in dogs. Focused CEUS following CE-MDCT or B-mode ultrasonography may be beneficial for identifying potentially significant hypoperfused lesions. © 2013 Veterinary Radiology & Ultrasound.

  14. Contrast-enhanced MR mammography for evaluation of the contralateral breast in patients with diagnosed unilateral breast cancer or high-risk lesions.

    Science.gov (United States)

    Pediconi, Federica; Catalano, Carlo; Roselli, Antonella; Padula, Simona; Altomari, Fiorella; Moriconi, Enrica; Pronio, Anna Maria; Kirchin, Miles A; Passariello, Roberto

    2007-06-01

    To prospectively evaluate accuracy of gadobenate dimeglumine-enhanced magnetic resonance (MR) mammography for depiction of synchronous contralateral breast cancer in patients with newly diagnosed unilateral breast cancer or high-risk lesions, with histologic analysis or follow-up as reference. The study had ethics committee approval; all patients provided written informed consent. One hundred eighteen consecutive women (mean age, 52 years) with unilateral breast cancer or high-risk lesions and negative findings in the contralateral breast at physical examination, ultrasonography, and conventional mammography underwent gadobenate dimeglumine-enhanced 1.5-T MR mammography. Transverse three-dimensional T1-weighted gradient-echo images were acquired before and at 0, 2, 4, 6, and 8 minutes after gadobenate dimeglumine administration (0.1 mmol per kilogram body weight). Breast Imaging Reporting and Data System (BI-RADS) was used to categorize breast density and the level of suspicion for malignant contralateral breast lesions. Results were compared with histologic findings. Sensitivity, specificity, accuracy, and positive and negative predictive values for contrast-enhanced MR mammography were evaluated. Contrast-enhanced MR mammography revealed contralateral lesions in 28 (24%) of 118 patients. Twenty-four lesions were detected in patients with dense breasts (BI-RADS breast density category III or IV). Lesions in eight (29%) of 28 patients were BI-RADS category 4; patients underwent biopsy. Lesions in 20 (71%) patients were BI-RADS category 5; patients underwent surgery. At histologic analysis, 22 lesions were confirmed as malignant; six lesions were fibroadenomas. No false-negative lesions were detected; none of the fibroadenomas were BI-RADS category 5. The sensitivity, specificity, accuracy, and positive and negative predictive values of contrast-enhanced MR mammography for depiction of malignant or high-risk contralateral lesions were 100%, 94%, 95%, 79%, and 100

  15. Characterization of the enhancing lesions on dynamic contrast enhanced magnetic resonance imaging in patients with interstitial mammoplasty

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Yun [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kim, Sung Hun, E-mail: rad-ksh@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kang, Bong Joo [Department of Radiology, Seoul St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Kim, Hyeon Sook [Department of Radiology, St. Paul Hospital, The Catholic University of Korea (Korea, Republic of); Cha, Eun Suk [Department of Radiology, Ewha Womans University, School of Medicine, Mokdong Hospital (Korea, Republic of); Kim, Ji Youn [Department of Radiology, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Song, Byung Joo [Department of Surgery, Seoul St. Mary' s Hospital, The Catholic University of Korea, Seoul (Korea, Republic of)

    2013-12-01

    Purpose: The purpose of this study was to categorize the morphologic and kinetic features of enhancing lesions in breasts with interstitial mammoplasty using dynamic contrast-enhanced magnetic resonance imaging and to assess factors predictive of breast cancer. Materials and methods: We retrospectively reviewed the clinical and radiological data of 21 enhancing lesions in 19 patients with interstitial mammoplasty, who underwent breast magnetic resonance imaging and biopsy or an operation in our hospital from September 2008 to July 2012. These lesions were sorted by morphological and kinetic features and final assessment category according to the BI-RADS lexicon. Results: Nine cases were confirmed to be ductal carcinoma in situ (n = 2) and invasive ductal carcinoma (n = 7), and the remaining 12 cases were fibrocystic disease (n = 2), fibroadenoma (n = 2), fat necrosis (n = 1), foreign body granuloma (n = 3) and silicone mastitis (n = 1). Common features of malignancy included irregular shape (50.0%), spiculated margins (75.0%), heterogeneous enhancement (50.0%) and type III kinetic pattern (87.5%). The correlations of margins and kinetic curve pattern with benignity and malignancy approached statistical significance (p = 0.02, respectively). We found no correlation for shape (p = 0.33) or internal enhancement (p = 0.42) between lesion types. The malignancy rate of enhancing lesions was 42.8% (9/21). The sensitivity and specificity of dynamic contrast-enhanced magnetic resonance imaging were 100% and 16.67%, respectively. The positive predictive value, negative predictive value and accuracy of magnetic resonance imaging were 47.38%, 100% and 52.38%. Overall inter-observer agreement for the kinetic curve pattern was good (κ = 0.67). Moderate agreement was seen in describing the shape, margin, enhancement and assessing the final category (κ = 0.59, 0.46, 0.58 and 0.49, respectively). Conclusion: Dynamic contrast-enhanced magnetic resonance imaging had a high

  16. Collateral circulation formation determines the characteristic profiles of contrast-enhanced MRI in the infarcted myocardium of pigs

    Science.gov (United States)

    Wang, Jian; Xiang, Bo; Lin, Hung-yu; Liu, Hong-yu; Freed, Darren; Arora, Rakesh C; Tian, Gang-hong

    2015-01-01

    Aim: To investigate the relationship between the collateral circulation and contrast-enhanced MR signal change for myocardial infarction (MI) in pigs. Methods: Pigs underwent permanent ligation of two diagonal branches of the left anterior descending artery. First-pass perfusion (FPP) MRI (for detecting myocardial perfusion abnormalities) and delayed enhancement (DE) MRI (for estimating myocardial infarction) using Gd-DTPA were performed at 2 h, 7 d and 4 weeks after the coronary occlusion. Myocardial blood flow (MBF) was evaluated using nonradioactive red-colored microspheres. Histological examination was performed to characterize the infarcts. Results: Acute MI performed at 2 h afterwards was characterized by hypoenhancement in both FPP- and DE-MRI, with small and almost unchanged FPP-signal intensity (SI) and DE-SI due to negligible MBF. Subacute MI detected 7 d afterwards showed small but significantly increaseing FPP-SI, and was visible as a sluggish hyperenhancement in DE-MRI with considerably higher DE-SI compared to the normal myocardium; the MBF approached the half-normal value. Chronic MI detected at 4 weeks afterwards showed increasing FPP-SI comparable to the normal myocardium, and a rapid hyperenhancement in DE-MRI with even higher DE-SI; the MBF was close to the normal value. The MBF was correlated with FPP-SI (r=+0.94, P<0.01) and with the peak DE-SI (r=+0.92, P<0.01) at the three MI stages. Remodeled vessels were observed at intra-infarction and peri-infarction zones during the subacute and chronic periods. Conclusion: Progressive collateral recovery determines the characteristic profiles of contrast-enhanced MRI in acute, subacute and chronic myocardial infarction in pigs. The FPP- and DE-MRI signal profiles not only depend on the loss of tissue viability and enlarged interstitial space, but also on establishing a collateral circulation. PMID:25832427

  17. Image contrast enhancement using adjacent-blocks-based modification for local histogram equalization

    Science.gov (United States)

    Wang, Yang; Pan, Zhibin

    2017-11-01

    Infrared images usually have some non-ideal characteristics such as weak target-to-background contrast and strong noise. Because of these characteristics, it is necessary to apply the contrast enhancement algorithm to improve the visual quality of infrared images. Histogram equalization (HE) algorithm is a widely used contrast enhancement algorithm due to its effectiveness and simple implementation. But a drawback of HE algorithm is that the local contrast of an image cannot be equally enhanced. Local histogram equalization algorithms are proved to be the effective techniques for local image contrast enhancement. However, over-enhancement of noise and artifacts can be easily found in the local histogram equalization enhanced images. In this paper, a new contrast enhancement technique based on local histogram equalization algorithm is proposed to overcome the drawbacks mentioned above. The input images are segmented into three kinds of overlapped sub-blocks using the gradients of them. To overcome the over-enhancement effect, the histograms of these sub-blocks are then modified by adjacent sub-blocks. We pay more attention to improve the contrast of detail information while the brightness of the flat region in these sub-blocks is well preserved. It will be shown that the proposed algorithm outperforms other related algorithms by enhancing the local contrast without introducing over-enhancement effects and additional noise.

  18. Counter-propagating wave interaction for contrast-enhanced ultrasound imaging

    NARCIS (Netherlands)

    G. Renaud (G.); J.G. Bosch (Hans); E.J.G. Sijbrands (Eric); V. Shamdasani (V.); R. Entrekin (R.); N. de Jong (Nico); A.F.W. van der Steen (Ton)

    2012-01-01

    textabstractMost techniques for contrast-enhanced ultrasound imaging require linear propagation to detect nonlinear scattering of contrast agent microbubbles. Waveform distortion due to nonlinear propagation impairs their ability to distinguish microbubbles from tissue. As a result, tissue can be

  19. Characterizing EPR-mediated passive drug targeting using contrast-enhanced functional ultrasound imaging

    NARCIS (Netherlands)

    Theek, B.; Gremse, F.; Kunjachan, S.; Fokong, S.; Pola, R.; Pechar, M.; Deckers, R.; Storm, Gerrit; Ehling, J.; Kiessling, F.; Lammers, Twan Gerardus Gertudis Maria

    2014-01-01

    The Enhanced Permeability and Retention (EPR) effect is extensively used in drug delivery research. Taking into account that EPR is a highly variable phenomenon, we have here set out to evaluate if contrast-enhanced functional ultrasound (ceUS) imaging can be employed to characterize EPR-mediated

  20. Dynamic contrast-enhanced MRI for monitoring response to neoadjuvant chemotherapy in breast cancer

    NARCIS (Netherlands)

    Loo, C.E.

    2016-01-01

    The general aim of this thesis is to investigate the role of dynamic contrast-enhanced MRI in monitoring response of breast cancer during neoadjuvant chemotherapy. The role of MRI with respect to achieving personalized breast cancer treatment by improving response monitoring is examined. Our

  1. Medical Image Visual Appearance Improvement Using Bihistogram Bezier Curve Contrast Enhancement: Data from the Osteoarthritis Initiative

    Science.gov (United States)

    Gan, Hong-Seng; Swee, Tan Tian; Abdul Karim, Ahmad Helmy; Sayuti, Khairil Amir; Abdul Kadir, Mohammed Rafiq; Tham, Weng-Kit; Wong, Liang-Xuan; Chaudhary, Kashif T.; Yupapin, Preecha P.

    2014-01-01

    Well-defined image can assist user to identify region of interest during segmentation. However, complex medical image is usually characterized by poor tissue contrast and low background luminance. The contrast improvement can lift image visual quality, but the fundamental contrast enhancement methods often overlook the sudden jump problem. In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of “adequate contrast enhancement” to overcome sudden jump problem in knee magnetic resonance image. Since every image produces its own intensity distribution, the adequate contrast enhancement checks on the image's maximum intensity distortion and uses intensity discrepancy reduction to generate Bezier transform curve. The proposed method improves tissue contrast and preserves pertinent knee features without compromising natural image appearance. Besides, statistical results from Fisher's Least Significant Difference test and the Duncan test have consistently indicated that the proposed method outperforms fundamental contrast enhancement methods to exalt image visual quality. As the study is limited to relatively small image database, future works will include a larger dataset with osteoarthritic images to assess the clinical effectiveness of the proposed method to facilitate the image inspection. PMID:24977191

  2. Attenuation Correction and Normalisation for Quantification of Contrast Enhancement in Ultrasound Images of Carotid Arteries.

    Science.gov (United States)

    Cheung, Wing Keung; Gujral, Dorothy M; Shah, Benoy N; Chahal, Navtej S; Bhattacharyya, Sanjeev; Cosgrove, David O; Eckersley, Robert J; Harrington, Kevin J; Senior, Roxy; Nutting, Christopher M; Tang, Meng-Xing

    2015-07-01

    An automated attenuation correction and normalisation algorithm was developed to improve the quantification of contrast enhancement in ultrasound images of carotid arteries. The algorithm first corrects attenuation artefact and normalises intensity within the contrast agent-filled lumen and then extends the correction and normalisation to regions beyond the lumen. The algorithm was first validated on phantoms consisting of contrast agent-filled vessels embedded in tissue-mimicking materials of known attenuation. It was subsequently applied to in vivo contrast-enhanced ultrasound (CEUS) images of human carotid arteries. Both in vitro and in vivo results indicated significant reduction in the shadowing artefact and improved homogeneity within the carotid lumens after the correction. The error in quantification of microbubble contrast enhancement caused by attenuation on phantoms was reduced from 55% to 5% on average. In conclusion, the proposed method exhibited great potential in reducing attenuation artefact and improving quantification in contrast-enhanced ultrasound of carotid arteries. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  3. Medical Image Visual Appearance Improvement Using Bihistogram Bezier Curve Contrast Enhancement: Data from the Osteoarthritis Initiative

    Directory of Open Access Journals (Sweden)

    Hong-Seng Gan

    2014-01-01

    Full Text Available Well-defined image can assist user to identify region of interest during segmentation. However, complex medical image is usually characterized by poor tissue contrast and low background luminance. The contrast improvement can lift image visual quality, but the fundamental contrast enhancement methods often overlook the sudden jump problem. In this work, the proposed bihistogram Bezier curve contrast enhancement introduces the concept of “adequate contrast enhancement” to overcome sudden jump problem in knee magnetic resonance image. Since every image produces its own intensity distribution, the adequate contrast enhancement checks on the image’s maximum intensity distortion and uses intensity discrepancy reduction to generate Bezier transform curve. The proposed method improves tissue contrast and preserves pertinent knee features without compromising natural image appearance. Besides, statistical results from Fisher’s Least Significant Difference test and the Duncan test have consistently indicated that the proposed method outperforms fundamental contrast enhancement methods to exalt image visual quality. As the study is limited to relatively small image database, future works will include a larger dataset with osteoarthritic images to assess the clinical effectiveness of the proposed method to facilitate the image inspection.

  4. Contrast-enhanced dynamic MR imaging of postmolar gestational trophoblastic disease

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Y. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Torashima, M. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Takahashi, M. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Mizutani, H. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Miyazaki, K. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Matsuura, K. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan); Okamura, H. [Depts. of Radiology and Obstetrics and Gynecology, Kumamoto Univ. School of Medicine (Japan)

    1995-03-01

    Conventional spin-echo (SE) and contrast-enhanced dynamic MR imaging were performed on a 1.5 T superconductive unit for evaluation of myometrial lesions in postmolar gestational trophoblastic disease (GTD) in 10 women. MR imaging was done at the time of the initial examination (n=10), during (n=6), and after repeated courses of chemotherapy (n=10). The T2-weighted SE image revealed an enlarged uterus (n=7), disappearance of zonal anatomy (n=6), and heterogeneous signal intensities (n=8) with prominent flow voids (n=7). However, these abnormalities remained after repeated courses of chemotherapy, when the S-{beta}-HCG level returned to the normal range. Myometrial lesions characteristically had marked enhancement with areas of unenhancement on dynamic MR images in patients with highly elevated S-{beta}-HCG. Areas of contrast enhancement correlated with changes in S-{beta}-HCG level. The enhancement was reduced with decrease in S-{beta}-HCG level after repeated courses of chemotherapy. Six of 8 masses seen on T2-weighted images proved to be active trophoblastic lesions and 2 masses proved to be hematoma or necrosis. In 2 patients, abnormal myometrial lesions were detected only on contrast-enhanced dynamic MR imaging. These preliminary data indicate that contrast-enhanced dynamic MR imaging more clearly demonstrates myometrial involvement of postmolar GTD than conventional SE imaging. (orig.).

  5. Post-radiotherapy contrast enhancement changes in fast dynamic MRI of cervical carcinoma.

    NARCIS (Netherlands)

    Boss, E.A.; Massuger, L.F.A.G.; Pop, L.A.M.; Verhoef, C.G.; Huisman, H.J.; Boonstra, H.; Barentsz, J.O.

    2001-01-01

    This pilot study determines fast dynamic gadolinium enhanced MRI contrast enhancement parameters (onset of enhancement and time to peak enhancement) before and after radiotherapy in 10 cervical carcinoma patients. Before radiotherapy, onset of enhancement and time to peak enhancement were early,

  6. Identifying the association between contrast enhancement pattern, surgical resection, and prognosis in anaplastic glioma patients

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yinyan; Jiang, Tao [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); Capital Medical University, Beijing Neurosurgical Institute, Beijing (China); Wang, Kai; Li, Shaowu; Ma, Jun [Capital Medical University, Department of Neuroradiology, Beijing Tiantan Hospital, Beijing (China); Wang, Jiangfei [Capital Medical University, Department of Neurosurgery, Beijing Tiantan Hospital, Beijing (China); Dai, Jianping [Capital Medical University, Beijing Neurosurgical Institute, Beijing (China); Capital Medical University, Department of Neuroradiology, Beijing Tiantan Hospital, Beijing (China)

    2016-04-15

    Contrast enhancement observable on magnetic resonance (MR) images reflects the destructive features of malignant gliomas. This study aimed to investigate the relationship between radiologic patterns of tumor enhancement, extent of resection, and prognosis in patients with anaplastic gliomas (AGs). Clinical data from 268 patients with histologically confirmed AGs were retrospectively analyzed. Contrast enhancement patterns were classified based on preoperative T1-contrast MR images. Univariate and multivariate analyses were performed to evaluate the prognostic value of MR enhancement patterns on progression-free survival (PFS) and overall survival (OS). The pattern of tumor contrast enhancement was associated with the extent of surgical resection in AGs. A gross total resection was more likely to be achieved for AGs with focal enhancement than those with diffuse (p = 0.001) or ring-like (p = 0.024) enhancement. Additionally, patients with focal-enhanced AGs had a significantly longer PFS and OS than those with diffuse (log-rank, p = 0.025 and p = 0.031, respectively) or ring-like (log-rank, p = 0.008 and p = 0.011, respectively) enhanced AGs. Furthermore, multivariate analysis identified the pattern of tumor enhancement as a significant predictor of PFS (p = 0.016, hazard ratio [HR] = 1.485) and OS (p = 0.030, HR = 1.446). Our results suggested that the contrast enhancement pattern on preoperative MR images was associated with the extent of resection and predictive of survival outcomes in AG patients. (orig.)

  7. Evaluation of breast lesions with contrast-enhanced ultrasound using the microvascular imaging technique: initial observations.

    Science.gov (United States)

    Liu, He; Jiang, Yu-Xin; Liu, Ji-Bin; Zhu, Qing-Li; Sun, Qiang

    2008-10-01

    The objective of this study was to evaluate the usefulness of contrast-enhanced ultrasound using the microvascular imaging technique in the diagnosis of breast lesions. In 104 patients with 104 breast lesions scheduled for surgery, conventional and contrast-enhanced ultrasound using the microvascular imaging technique were performed after administration of SonoVue. The enhancement patterns of breast lesions were classified as no enhancement, peripheral enhancement, homogeneous enhancement, regional enhancement, or heterogeneous enhancement based on the morphologic features of enhancement. The diagnostic value of contrast-enhanced ultrasound using the microvascular imaging technique was analyzed with the observers blinded to the clinical data and pathology (which served as the gold standard). None of the enhancement patterns was suggestive of benignity, with a sensitivity of 18.3%, specificity of 97.7%, positive predictive value (PPV) of 91.7%, negative predictive value (NPV) of 46.2%, and accuracy of 51.5%. The peripheral enhancement pattern was suggestive of malignancy, with a sensitivity of 39.5%, specificity of 98.3%, PPV of 94.4%, NPV of 69.4%, and accuracy of 73.8%. Homogeneous, regional, and heterogeneous enhancement patterns did not show meaningful diagnostic information. Contrast-enhanced ultrasound using the microvascular imaging technique provides diagnostic information on breast lesions.

  8. Contrast-enhanced duplex scanning of crural arteries by means of continuous infusion of Levovist

    NARCIS (Netherlands)

    Coffi, Stephen B.; Ubbink, Dirk Th; Zwiers, Ineke; van Gurp, Johan A. M.; Hanson, Dianne; Legemate, Dink A.

    2004-01-01

    Objectives: To estimate the dosage needed for continuous infusion and to investigate whether continuous infusion of the ultrasound contrast-enhancing agent Levovist (SH U 508A) can improve duplex scanning of crural arteries in patients with peripheral arterial obstructive disease (PAOD) eligible for

  9. [Quantitative parametric analysis of contrast-enhanced lesions in dynamic MR mammography].

    Science.gov (United States)

    Hauth, E A M; Jaeger, H; Maderwald, S; Mühler, A; Kimmig, R; Forsting, M

    2008-06-01

    The aim of the study was an evaluation of the quantitative parametric analysis of contrast-enhanced lesions in dynamic MR mammography. In 137 patients, 183 contrast-enhanced lesions were identified in dynamic MR mammography. In 82 lesions histopathology was performed and in 101 lesions follow-up MR mammography was carried out. The contrast kinetics of lesions was analyzed quantitatively, on a pixel-by-pixel basis. The initial signal enhancement was coded by color intensity (bright, medium, dark), the post-initial signal enhancement was coded by color hue (blue, green, red). ROC analysis and logistic regression were performed. Malignant lesions showed a significantly higher number of bright red, medium red and dark red, bright green and medium green pixels than benign lesions. Benign lesions showed a significantly higher number of bright blue, medium blue and dark blue pixels than malignant lesions. The highest areas under the ROC curves (AUC) were found for medium red (AUC = 0.782) and medium green pixels (AUC = 0.733). A regression model with medium red and medium green pixels allows diagnosis of malignant lesions with a sensitivity of 60.7% and a specificity of 83.6%. The quantification of contrast-enhanced lesions allows objective analysis of the signal intensities in malignant and benign lesions. Therefore, this method might increase the specificity of MR mammography. Further developments are necessary before this method can be used for routine analysis of contrast-enhancing lesions in MR mammography.

  10. Dual-energy contrast-enhanced digital mammography in routine clinical practice in 2013.

    Science.gov (United States)

    Badr, S; Laurent, N; Régis, C; Boulanger, L; Lemaille, S; Poncelet, E

    2014-03-01

    To date, analysis of the vascularisation of breast lesions mainly relies on MR imaging. However, the accessibility of MRI is sometimes limited and has led to the development of new means of imaging, such as dual-energy contrast-enhanced mammography, which provides data on the vascularisation of the breast along with the usual morphological information. The purpose of this paper is to present this new imaging technique as well as the recent references, illustrated by clinical reports derived from our everyday practice to focus on the advantages and disadvantages of this new breast exploration. Dual-energy contrast-enhanced mammography is a recent, seemingly promising technique, in the management of breast cancer. The main advantages consist of its easy installation, the good tolerance and the comfort in the interpretation of difficult to read mammograms. However, the indications and the role of dual-energy contrast-enhanced mammography still have to be determined within the diagnostic strategy of breast tumours. New studies are expected, especially to compare dual-energy contrast-enhanced mammography with breast MRI. Copyright © 2013 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  11. Clinical usefulness of contrast-enhanced MP-RAGE of the brain

    Energy Technology Data Exchange (ETDEWEB)

    Hauwe, L. van den [Department of Radiology, Universitair Ziekenhuis Antwerpen, Wilrijkstraat 10, B-2650 Edegem (Belgium); Parizel, P.M. [Department of Radiology, Universitair Ziekenhuis Antwerpen, Wilrijkstraat 10, B-2650 Edegem (Belgium); Goethem, J.W. van [Department of Radiology, Universitair Ziekenhuis Antwerpen, Wilrijkstraat 10, B-2650 Edegem (Belgium); Schepper, A.M.A. de [Department of Radiology, Universitair Ziekenhuis Antwerpen, Wilrijkstraat 10, B-2650 Edegem (Belgium)

    1996-05-01

    Our purpose was to evaluate the usefulness of a 3D T1-weighted gradient-echo sequence (MP-RAGE) in clinical practice. We prospectively examined 200 patients with a variety of neurological disorders and symptoms. We compared lesion conspicuity and contrast enhancement on MP-RAGE images with conventional gadolinium-enhanced spin-echo (SE) T1-weighted images. Both the original MP-RAGE data and the reformatted images were characterised by improved differentiation between grey and white matter. More lesions were found on the 3D series, in both patients with neoplastic and non-neoplastic disease. Contrast enhancement of small oedematous lesions affecting the white matter in demyelinating disease was less obvious. Multiplanar reformatting, which can be realised in any desired plane and surface rendering with sophisticated segmentation algorithms superbly displayed the underlying anatomical relationships between lesions and normal brain structures. Excellent spatial resolution, the absence of posterior fossa artefacts and equivalent contrast enhancement resulted in an increased number of space-occupying lesions being found on the MP-RAGE images. Thus contrast-enhanced MP-RAGE is an alternative to conventional SE imaging in the investigation of intracranial masses. Although the total number of lesions found in patients with demyelinating disease was significantly higher on MP-RAGE, demonstration of blood-brain-barrier breakdown in active lesions was less obvious. (orig.). With 5 figs., 2 tabs.

  12. Blood Pool Agent Contrast-Enhanced MRA: Level-Set Based Artery-Vein Separation

    NARCIS (Netherlands)

    van Bemmel, C.M.; Spreeuwers, Lieuwe Jan; Verdonck, B.; Viergever, M.A.; Niessen, W.J.

    2002-01-01

    Blood pool agents (BPAs) for contrast-enhanced magnetic resonance angiography (CE-MRA) allow prolonged imaging times for higher contrast and resolution by imaging during the steady state when the contrast agent is distributed through the complete vascular system. However, simultaneous arterial and

  13. Spleen evaluation using contrast enhanced ultrasonography and Doppler in dogs with subclinical ehrlichiosis

    Directory of Open Access Journals (Sweden)

    M.C. Maronezi

    2015-12-01

    Full Text Available The aim of this study was to evaluate the splenic parenchyma of dogs with subclinical ehrlichiosis using Doppler and contrast-enhanced ultrasonography and provide reference values for this organ in affected animals. Seventeen dogs naturally infected with E. canis were selected for this study. Splenic parenchyma echotexture and echogenicity, size and borders were determined by ultrasound scan. The vascular indices of the splenic artery were determined by Doppler. SonoVue, at 0.1mL per animal, was used in microbubble contrast-enhanced ultrasonography to determine wash in, wash out and peak enhancement time in the splenic tissue. B-mode ultrasonography revealed splenomegaly with rounded borders, heterogeneous echotexture and mixed echogenicity. The vascular indices of the splenic artery were: systolic velocity of 22.59±8.07cm/s, diastolic velocity of 5.25±4.66cm/s and resistance index of 0.71±0.14; values not yet reported in Veterinary Medicine. Contrast-enhanced ultrasonography recorded wash in time of 5.31±0.7s, peak enhancement time of 18.56±2.90s and wash out time of 94.56±35.21s. The combination of conventional ultrasonography of the spleen and hemodynamic evaluation by Doppler and contrast-enhanced ultrasonography is important for the diagnosis of canine ehrlichiosis and could help monitor the clinical evolution of subclinical cases.

  14. A novel approach to tracer-kinetic modeling for (macromolecular) dynamic contrast-enhanced MRI

    NARCIS (Netherlands)

    Jacobs, Igor; Strijkers, Gustav J.; Keizer, Henk M.; Janssen, Henk M.; Nicolay, Klaas; Schabel, Matthias C.

    2016-01-01

    To develop a novel tracer-kinetic modeling approach for multi-agent dynamic contrast-enhanced MRI (DCE-MRI) that facilitates separate estimation of parameters characterizing blood flow and microvascular permeability within one individual. Monte Carlo simulations were performed to investigate the

  15. Abducens nerve enhancement demonstrated by multiplanar reconstruction of contrast-enhanced three-dimensional MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hosoya, T.; Adachi, M.; Sugai, Y. [Dept. of Radiology, Yamagata University School of Medicine (Japan); Yamaguchi, K.; Yamaguchi, K. [Dept. of Ophthalmology, Yamagata University School of Medicine (Japan); Kato, T. [3. Dept. of Internal Medicine, Yamagata University School of Medicine (Japan)

    2001-04-01

    We describe contrast enhancement of the cisternal portion of the abducens nerve and discuss its clinical significance. We examined 67 patients with ophthalmoplegia using contrast-enhanced 3-dimensional (3D) MRI with multiplanar reconstruction along the nerves and found 16 patients (ten men, six women), aged 10-73 years (mean 34.4 years), with contrast enhancement of the abducens nerve. Of the 36 patients who had an abducens palsy, 14 (39 %) showed contrast enhancement. In the 16 patients, 23 abducens nerves enhanced; 13 were symptomatic and 10 asymptomatic at the time. The causes were disseminated tumour (1), an inflammatory process (3), trauma (2), ischaemia (2) and autoimmune diseases (8), such as the Miller Fisher syndrome, acute ophthalmoparesis, polyneuropathy and multiple sclerosis. Abducens and/or oculomotor nerve enhancement was the only abnormality on MRI in the patients with traumatic or ischaemic neuropathy or autoimmune diseases. There were 14 patients who recovered fully within 1-6 months after treatment, and resolution of the enhancement correlated well with recovery. (orig.)

  16. Contrast enhancement by lipid-based MRI contrast agents in mouse atherosclerotic plaques; a longitudinal study

    NARCIS (Netherlands)

    den Adel, Brigit; van der Graaf, Linda M.; Que, Ivo; Strijkers, Gustav J.; Löwik, Clemens W.; Poelmann, Robert E.; van der Weerd, Louise

    2013-01-01

    The use of contrast-enhanced MRI to enable in vivo specific characterization of atherosclerotic plaques is increasing. In this study the intrinsic ability of two differently sized gadolinium-based contrast agents to enhance atherosclerotic plaques in ApoE(-/-) mice was evaluated with MRI. We

  17. Modeling Dynamic Contrast-Enhanced MRI Data with a Constrained Local AIF

    DEFF Research Database (Denmark)

    Duan, Chong; Kallehauge, Jesper F.; Pérez-Torres, Carlos J

    2017-01-01

    PURPOSE: This study aims to develop a constrained local arterial input function (cL-AIF) to improve quantitative analysis of dynamic contrast-enhanced (DCE)-magnetic resonance imaging (MRI) data by accounting for the contrast-agent bolus amplitude error in the voxel-specific AIF. PROCEDURES...

  18. Contrast enhanced digital mammography: Is it useful in detecting lesions in edematous breast?

    Directory of Open Access Journals (Sweden)

    Noha Abd ElShafy ElSaid

    2015-09-01

    Conclusion: Dual-energy contrast-enhanced digital mammography is a useful technique in identification of lesions in mammographically dense edematous breasts and proved to be a useful tool in the follow-up of cases presenting by edema after conservative breast surgery and chemotherapy.

  19. Arterial input function calculation in dynamic contrast-enhanced MRI: an in vivo validation study using co-registered contrast-enhanced ultrasound imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mehrabian, Hatef; Chandrana, Chaitanya; Pang, Ian; Chopra, Rajiv; Martel, Anne L. [University of Toronto, Department of Medical Biophysics, Sunnybrook Research Institute, Toronto, ON (Canada)

    2012-08-15

    Developing a method of separating intravascular contrast agent concentration to measure the arterial input function (AIF) in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of tumours, and validating its performance in phantom and in vivo experiments. A tissue-mimicking phantom was constructed to model leaky tumour vasculature and DCE-MR images of this phantom were acquired. An in vivo study was performed using tumour-bearing rabbits. Co-registered DCE-MRI and contrast-enhanced ultrasound (CEUS) images were acquired. An independent component analysis (ICA)-based method was developed to separate the intravascular component from DCE-MRI. Results were validated by comparing the time-intensity curves with the actual phantom and in vivo curves. Phantom study: the AIF extracted using ICA correlated well with the true intravascular curve. In vivo study: the AIFs extracted from DCE-MRI using ICA were very close to the true AIF. Intravascular component images were very similar to the CEUS images. The contrast onset times and initial wash-in slope of the ICA-derived AIF showed good agreement with the CEUS curves. ICA has the potential to separate the intravascular component from DCE-MRI. This could eliminate the requirement for contrast medium uptake measurements in a major artery and potentially result in more accurate pharmacokinetic parameters. (orig.)

  20. Delayed contrast-enhanced computed tomography in patients with known or suspected cardiac sarcoidosis: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Aikawa, Tadao; Naya, Masanao; Obara, Masahiko [Hokkaido University Graduate School of Medicine, Sapporo (Japan); Oyama-Manabe, Noriko; Kudo, Kohsuke [Hokkaido University Hospital, Department of Diagnostic and Interventional Radiology, Sapporo (Japan); Ohira, Hiroshi; Sugimoto, Ayako; Tsujino, Ichizo [Hokkaido University Graduate School of Medicine, First Department of Medicine, Sapporo (Japan); Manabe, Osamu; Tamaki, Nagara [Hokkaido University Graduate School of Medicine, Department of Nuclear Medicine, Sapporo (Japan); Tsutsui, Hiroyuki [Kyushu University, Department of Cardiovascular Medicine, Fukuoka (Japan)

    2017-10-15

    To evaluate the diagnostic value of delayed contrast-enhanced computed tomography (DE-CT) for cardiac sarcoidosis (CS) in patients with or without implantable devices, including a quantitative comparison with late gadolinium enhancement cardiac magnetic resonance (LGE-CMR). Twenty-four patients (mean age, 64 ± 9 years; 17 women) with known or suspected CS underwent retrospective electrocardiogram-gated DE-CT at 80 kV with knowledge-based iterative model reconstruction. Fourteen patients without implantable devices also underwent LGE-CMR, while ten with pacemakers or implantable cardioverter-defibrillators did not. The presence of hyperenhanced myocardium was assessed visually and quantitatively using a 5-standard deviation threshold above the mean of remote myocardium. Inter-observer agreement for visual detection of hyperenhanced segments on DE-CT was excellent in patients with implantable devices and in those without (κ = 0.91 and κ = 0.94, respectively). Comparisons of the percent area of hyperenhanced myocardium between DE-CT and LGE-CMR on both per-patient and per-segment analyses showed good correlations (r = 0.96 and r = 0.83, respectively; p < 0.001). The sensitivity and specificity of DE-CT for the diagnosis of CS were 94% and 33%. The extent of hyperenhanced lesion with DE-CT showed good agreement with LGE-CMR results. DE-CT showed high sensitivity for detecting CS and may be useful particularly in patients with contraindications to CMR. (orig.)

  1. Contrast-enhanced ultrasound in the characterisation of breast masses: utility of quantitative analysis in comparison with MRI

    Energy Technology Data Exchange (ETDEWEB)

    Caproni, Natalia; Pecchi, Annarita; Canossi, Barbara; Battista, Rachele; D' Alimonte, Piero [Az. Ospedaliero-universitaria Policlinico, Department of Radiology, Modena (Italy); Marchisio, Francesca [Nuovo Ospedale Civile di Sassuolo, Department of Radiology, Modena (Italy); Torricelli, Pietro [Universita degli Studi di Modena e Reggioemilia, Department of Radiology, Modena (Italy)

    2010-06-15

    To evaluate the reliability of contrast-enhanced ultrasound quantitative analysis (CE-US) in characterizing breast lesions, in comparison with MRI. Thirty-nine patients with breast lesions BI-RADS 3-5 at US or mammography underwent CE-US and MRI. All lesions underwent histological and quantitative enhancement evaluation with both imaging methods. B-mode US, colour/power Doppler US and CE-US were used; an amplitude and phase modulation technique (CPS) read the signals produced by microbubbles and dedicated software produced the following parameters on time/intensity (T/I) curves: peak %, time to peak (TTP), mean transit time (MTT), regional blood volume (RBV) and regional blood flow (RBF). Student's t test was used to calculate the diagnostic accuracy of CE-US parameters compared with histological results. MRI (1.5 T) was performed before and after bolus gadolinium enhancement. Time/intensity curves were generated for all nodules and Fischer's multimodal score was used to classify them. Pathology showed 43 nodules (11 benign; 32 malignant). Peak and RBF were the most significant parameters in differential diagnosis, with p values of 0.02 and 0.004, respectively. Positive predictive value (PPV) of CE-US evaluation was 91%, negative predictive value (NPV) was 73% with a high concordance index (k = 0.59) with MRI. CE-US quantitative analysis offers an objective and reproducible assessment of lesion vascularisation, with good correlation with the results of MRI. (orig.)

  2. EVALUATION OF CONTRAST-ENHANCED ULTRASONOGRAPHY AS A METHOD FOR DETECTING GALLBLADDER NECROSIS OR RUPTURE IN DOGS.

    Science.gov (United States)

    Bargellini, Paolo; Orlandi, Riccardo; Paloni, Chiara; Rubini, Giuseppe; Fonti, Paolo; Peterson, Mark E; Rishniw, Mark; Boiti, Cristiano

    2016-11-01

    Gall bladder necrosis and rupture are life-threatening conditions in dogs requiring surgical intervention and early diagnosis is essential. Human patients with suspected gall bladder necrosis/rupture are commonly evaluated with contrast-enhanced ultrasonography (CEUS), however this procedure has not been described in dogs with suspected gall bladder necrosis/rupture. In a prospective diagnostic cohort study, CEUS (using SonoVue contrast medium) was performed in 93 dogs with gallbladder lesions identified by abdominal conventional ultrasonography. Necrosis/rupture was identified by CEUS as a focal lack of enhancement of the gallbladder wall. Dogs with positive CEUS finding for necrosis/rupture (complete lack of regional wall enhancement) underwent immediate surgery as did dogs with other biliary disorders requiring surgery. Dogs with negative CEUS findings or those not requiring surgery were managed medically. In cases undergoing surgery, necrosis/rupture was confirmed intraoperatively (and via histopathology). Absence of necrosis/rupture was confirmed either intraoperatively (via histopathology) or was assumed to be absent by complete recovery with medical management. Forty-nine dogs underwent surgery and cholecystectomy: 24 had necrosis/rupture. CEUS was more accurate (100% sensitive and specific) in diagnosing gallbladder wall necrosis/rupture than conventional ultrasonography (75% sensitive and 81% specific) (P < 0.03). In conclusion, CEUS provides accurate characterization of gallbladder wall integrity that can impact decisions regarding clinical management, either surgical or medical. © 2016 American College of Veterinary Radiology.

  3. Pelvic congestion syndrome initially detected by contrast enhanced F 18 FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Weung; Kim, Myoung Hyoung; Kim, Woo Hyoung; Kim, Chang Guhn [Wonkwang Univ. School of Medicine, Iksan (Korea, Republic of)

    2012-03-15

    Pelvic congestion syndrome (PCS) is said to occur as a result of retrograde flow in an incompetent ovarian vein. Ovarian vein incompetence is seen in approximately 10% of women, and up to 60% with this abnormality can develop PCS. The etiology of PCS is poorly understood and is likely to be multifactorial. Absence of ovarian vein valves is an important factor in its development. The causes of ovarian varicoceles are multifactorial, involving both mechanical and hormonal factors. Dilatation of the ovarian veins can result in vascular incompetence and retrograde blood flow. On either CT or magnetic resonance (MR) imaging studies, pelvic varices in PCS appear as dilated, tortuous, enhancing tubular structures near the ovaries and uterus. In addition, the extension of varices to the broad ligament and paravaginal venous plexus can be appreciated. With CT, the tubular nature of these structures and the pattern of enhancement after intravenous contrast medium administration distinguish them from lymphadenopathy or adnexal masses. Unlike such masses, pelvic varices appear isodense with other veins after contrast enhancement. Contrast enhanced CT data as part of the combined PET/CT examination provide additional information when compared with non enhanced PET/CT. Because CT data supply the anatomic background for PET, the most important benefit relates to more precise anatomic localization of pathology by differentiation of the lesion from its surrounding structures. By supporting lesion detection and characterization, CT contrast agents can be of additional value in F 18 FDG non avid disease. As in the presented case, careful review of CT images in contrast enhanced PET/CT enables the detection of F 18 FDG non avid disease such as PCS. As contrast enhanced F 18 FDG PET/CT had been performed frequently, being familiar with the findings of PCS on the contrast enhanced CT images would have been helpful for the nuclear medicine physicians.

  4. Contrast-enhanced endoscopic ultrasound in discrimination between benign and malignant mediastinal and abdominal lymph nodes.

    Science.gov (United States)

    Hocke, Michael; Menges, Markus; Topalidis, Theodor; Dietrich, Christoph F; Stallmach, Andreas

    2008-04-01

    Enlarged lymph nodes in the mediastinum reflect neoplastic, infectious or other diseases. The classification of these nodes is crucial in the management of the patient. Currently, only invasive measures obtaining tissue samples reach satisfying specificity. Contrast-enhanced endoscopic ultrasound (EUS) may offer a non-invasive alternative. A total of 122 patients (age: 63 +/- 15 years, 92 males, 30 females) with enlarged mediastinal and/or paraaortic lymph nodes diagnosed by CT scan were included in the study. EUS-guided fine needle aspiration was performed and cytologic specimens were diagnosed as representing a malignant or benign process in case of Papanicolau IV and V, or Papanicolau I and II, respectively. Based on cytology results, the investigated lymph nodes were classified as neoplastic (n = 48) or non-neoplastic lymph nodes. Using the B-mode criteria the preliminary diagnosis was confirmed in 64 out of 74 benign lymph nodes (specificity 86%). Regarding malignant lymph nodes 33 of 48 were confirmed (sensitivity 68%). Using the advanced contrast-enhanced EUS criteria the diagnosis was confirmed in 68 of 74 benign lymph nodes (specificity 91%). However, in case of malignant lymph nodes the number of correct diagnoses dropped to 29 of 48 lymph nodes (sensitivity 60%). The contrast-enhanced EUS criteria to identify benign lymph nodes and node enlargement in malignant lymphoma do not differ. If those ten patients with malignant lymphoma are excluded, the sensitivity of the contrast enhanced EUS for malignant lymph nodes rises to 73%. Contrast-enhanced EUS improves the specificity in diagnosing benign lymph nodes as compared to B-mode EUS. It does not improve the correct identification of malignant lymph nodes and cannot replace EUS-guided fine-needle aspiration.

  5. Clinical validation of semi-automated software for volumetric and dynamic contrast enhancement analysis of soft tissue venous malformations on magnetic resonance imaging examination

    Energy Technology Data Exchange (ETDEWEB)

    Caty, Veronique [Hopital Maisonneuve-Rosemont, Universite de Montreal, Department of Radiology, Montreal, QC (Canada); Kauffmann, Claude; Giroux, Marie-France; Oliva, Vincent; Therasse, Eric [Centre Hospitalier de l' Universite de Montreal (CHUM), Universite de Montreal and Research Centre, CHUM (CRCHUM), Department of Radiology, Montreal, QC (Canada); Dubois, Josee [Centre Hospitalier Universitaire Sainte-Justine et Universite de Montreal, Department of Radiology, Montreal, QC (Canada); Mansour, Asmaa [Institut de Cardiologie de Montreal, Heart Institute Coordinating Centre, Montreal, QC (Canada); Piche, Nicolas [Object Research System, Montreal, QC (Canada); Soulez, Gilles [Centre Hospitalier de l' Universite de Montreal (CHUM), Universite de Montreal and Research Centre, CHUM (CRCHUM), Department of Radiology, Montreal, QC (Canada); CHUM - Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada)

    2014-02-15

    To evaluate venous malformation (VM) volume and contrast-enhancement analysis on magnetic resonance imaging (MRI) compared with diameter evaluation. Baseline MRI was undertaken in 44 patients, 20 of whom were followed by MRI after sclerotherapy. All patients underwent short-tau inversion recovery (STIR) acquisitions and dynamic contrast assessment. VM diameters in three orthogonal directions were measured to obtain the largest and mean diameters. Volumetric reconstruction of VM was generated from two orthogonal STIR sequences and fused with acquisitions after contrast medium injection. Reproducibility (interclass correlation coefficients [ICCs]) of diameter and volume measurements was estimated. VM size variations in diameter and volume after sclerotherapy and contrast enhancement before sclerotherapy were compared in patients with clinical success or failure. Inter-observer ICCs were similar for diameter and volume measurements at baseline and follow-up (range 0.87-0.99). Higher percentages of size reduction after sclerotherapy were observed with volume (32.6 ± 30.7 %) than with diameter measurements (14.4 ± 21.4 %; P = 0.037). Contrast enhancement values were estimated at 65.3 ± 27.5 % and 84 ± 13 % in patients with clinical failure and success respectively (P = 0.056). Venous malformation volume was as reproducible as diameter measurement and more sensitive in detecting therapeutic responses. Patients with better clinical outcome tend to have stronger malformation enhancement. (orig.)

  6. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Sung [Dept. of Radiology, Ilsan Paik Hospital, College of Medicine, Inje University, Goyang (Korea, Republic of); Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Lee, Soo Rim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of); Hwang, Seong Su [Dept. of Radiology, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of); Lim, Yeon Soo [Dept. of Radiology, Bucheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Bucheon (Korea, Republic of); Park, Jeong Mi [Dept. of Radiology, Yeouido St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-02-15

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT.

  7. Self-gated 4D multiphase, steady-state imaging with contrast enhancement (MUSIC) using rotating cartesian K-space (ROCK): Validation in children with congenital heart disease.

    Science.gov (United States)

    Han, Fei; Zhou, Ziwu; Han, Eric; Gao, Yu; Nguyen, Kim-Lien; Finn, J Paul; Hu, Peng

    2017-08-01

    To develop and validate a cardiac-respiratory self-gating strategy for the recently proposed multiphase steady-state imaging with contrast enhancement (MUSIC) technique. The proposed SG strategy uses the ROtating Cartesian K-space (ROCK) sampling, which allows for retrospective k-space binning based on motion surrogates derived from k-space center line. The k-space bins are reconstructed using a compressed sensing algorithm. Ten pediatric patients underwent cardiac MRI for clinical reasons. The original MUSIC and 2D-CINE images were acquired as a part of the clinical protocol, followed by the ROCK-MUSIC acquisition, all under steady-state intravascular distribution of ferumoxytol. Subjective scores and image sharpness were used to compare the images of ROCK-MUSIC and original MUSIC. All scans were completed successfully without complications. The ROCK-MUSIC acquisition took 5 ± 1 min, compared to 8 ± 2 min for the original MUSIC. Image scores of ROCK-MUSIC were significantly better than original MUSIC at the ventricular outflow tracts (3.9 ± 0.3 vs. 3.3 ± 0.6, P ROCK-MUSIC in the other anatomic locations. ROCK-MUSIC provided images of equal or superior image quality compared to original MUSIC, and this was achievable with 40% savings in scan time and without the need for physiologic signal. Magn Reson Med 78:472-483, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. Pancreatic neuroendocrine tumors containing areas of iso- or hypoattenuation in dynamic contrast-enhanced computed tomography: Spectrum of imaging findings and pathological grading.

    Science.gov (United States)

    Hyodo, Ryota; Suzuki, Kojiro; Ogawa, Hiroshi; Komada, Tomohiro; Naganawa, Shinji

    2015-11-01

    To evaluate dynamic contrast-enhanced computed tomography (CT) features of pancreatic neuroendocrine tumors (PNETs) containing areas of iso- or hypoattenuation and the relationship with pathological grading. Between June 2006 and March 2014, 61 PNETs in 58 consecutive patients (29 male, 29 female; median-age 55 years), which were surgically diagnosed, underwent preoperative dynamic contrast-enhanced CT. PNETs were classified based on contrast enhancement patterns in the pancreatic phase: iso/hypo-PNETs were defined as tumors containing areas of iso- or hypoattenuation except for cystic components, and hyper-PNETs were tumors showing hyperattenuation over the whole area. CT findings and contrast-enhancement patterns of the tumors were evaluated retrospectively by two radiologists and compared with the pathological grading. Iso/hypo-PNETs comprised 26 tumors, and hyper-PNETs comprised 35 tumors. Not only hyper-PNETs but also most iso/hypo-PNETs showed peak enhancement in the pancreatic phase and a washout from the portal venous phase to the delayed phase. Iso/hypo-PNETs showed larger tumor size than the hyper-PNETs (mean, 3.7 cm vs. 1.6 cm; PIso/hypo-PNETs also showed significantly higher pathological grading (WHO 2010 classification; iso/hypo, G1=14, G2=11, G3=1; hyper, G1=34, G2=1; Piso/hypo-areas showed a rapid enhancement pattern as well as hyper-PNETs, various radiological features and higher malignant potential. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Usefulness of dynamic contrast enhanced lumbar spine MR imaging postoperative herniated lumbar disc

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ji Eun; Chung, Tae Sub; Kim, Young Soo; Cho, Yong Eun; Park, Mi Suk [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1999-02-01

    To compare the usefulness of dynamic contrast enhanced lumbar spine MR imaging with that of conventional delayed contrast enhanced MR imaging in the assessment of postoperative herniated lumbar disc. Forty-one postoperative herniated lumbar disc (HLD) lesions of 32 patients with back pain were examined with MR imaging (1.5T, Vision, Siemens, Germany). Five-phase dynamic 2D FLASH sagittal images (TR/TE = 118.1msec/4.1msec) were obtained every 19 seconds with a 4 minutes delayed image after contrast injection. As seen on delayed images, the discs were assessed as recurred, fibrosis, or no change. On dynamic images, the pattern of enhancement was evaluated as follows : Type 1 (no change in peripheral disc enhancement between the early and late phases) ; or Type 2 (minimal internal extension of marginal smooth enhancement during the late phase) ; or Type 3 (marked internal extension of peripheral irregular enhancement). Dynamic and delayed imaging were compared, and early epidural space enhancement with rapid wash-out was also evaluated. Of 41 postoperative HLDs, 39 lesions showed peripheral contrast enhancement. Evaluation depended on delayed imaging, and was as follows : recurred HLD (n=27) ; fibrosis (n=5) ; no change in postoperative disc (n=7). On dynamic contrast-enhanced imaging, enhancement patterns were Type 1 (n=29), Type 2 (n=7), and Type 3 (n=3). In 29 Type 1 lesions, there were no significant differences in image findings between dynamic and delayed images. However, in ten lesions (type 2 : n=7, type 3 : n=3), findings additional to those revealed by delayed images were demonstrated by dynamic contrast-enhanced MR imaging. Nine of the ten Type 2 and 3 lesions were diagnosed as recurred HLD. On dynamic images, five lesions showed early epidural space enhancement. Dynamic contrast-enhanced lumbar spine MR imaging provided additional findings such as increased peripheral disc enhancement, and epidural space enhancement, which cannot be detected on

  10. Distal aortic intramural hematoma: clinical importance of focal contrast enhancement on CT images.

    Science.gov (United States)

    Park, Gyung-Min; Ahn, Jung-Min; Kim, Dae-Hee; Kang, Joon-Won; Song, Jong-Min; Kang, Duk-Hyun; Lim, Tae-Hwan; Song, Jae-Kwan

    2011-04-01

    To investigate the prevalence, fate, and effect of focal contrast enhancement lesion within the hematoma on contrast material-enhanced computed tomographic (CT) images in patients with distal aortic intramural hematoma (IMH). This retrospective study was approved by the institutional review board; informed consent was waived. Clinical and CT data in 107 patients with distal IMH who received medical treatment were analyzed, including remodeling processes of IMH at follow-up CT. IMH progression was defined as development of aortic dissection (AD) and aneurysm or hematoma increase. The frequency of focal contrast enhancement was 39.3%, and hematoma was thicker in patients with focal contrast enhancement than in those without (12.3 mm ± 3.6 [standard deviation] vs 10.1 mm ± 4.1, P = .006). Although development of AD occurred more frequently in patients with focal contrast enhancement (21% vs 3%, P = .006), hematoma resorption (57% vs 71%) was the most common pattern of remodeling in both groups without any significant difference (P = .148). The frequency of development of aortic aneurysm (17% vs 14%, P = .690) and increase of hematoma (0% vs 5%, P = .278) was not significantly different between groups. The 1-, 3-, 5-, and 7-year survival rates were 96.3% ± 1.8, 95.2% ± 2.1, 87.9% ± 3.4, and 80.7% ± 4.4, respectively. Patients with IMH progression showed lower survival rates than those without (P = .028). While no significant difference in the overall survival rates could be demonstrated in patients with and those without focal contrast enhancement (P = .442), our study had only 17% power to detect a difference of 10%. Initial maximal aortic diameter was the only factor associated with survival rates (hazard ratio = 1.129; 95% confidence interval: 1.063, 1.199). The optimal cutoff for prediction of mortality within 7 years was 41 mm. Urgent intervention for patients with focal contrast enhancement is not necessary during the acute stage, and long-term close

  11. Application of dynamic susceptibility contrast-enhanced perfusion in temporal lobe epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Wu; Wang, Xiaoyi; Xie, Fangfang; Liao, Weihua [Dept. of Radiology, Xiangya Hospital of Central South Univ., Changsha (China)], e-mail: doctoring@sina.com

    2013-02-15

    Background: Accurately locatithe epileptogenic focus in temporal lobe epilepsy (TLE) is important in clinical practice. Single-photon emission computed tomography (SPECT) and positron-emission tomography (PET) have been widely used in the lateralization of TLE, but both have limitations. Magnetic resonance perfusion imaging can accurately and reliably reflect differences in cerebral blood flow and volume. Purpose: To investigate the diagnostic value of dynamic susceptibility contrast-enhanced (DSC) perfusion magnetic resonance imaging (MRI) in the lateralization of the epileptogenic focus in TLE. Material and Methods: Conventional MRI and DSC-MRI scanning was performed in 20 interictal cases of TLE and 20 healthy volunteers. The relative cerebral blood volume (rCBV) and relative cerebral blood flow (rCBF) of the bilateral mesial temporal lobes of the TLE cases and healthy control groups were calculated. The differences in the perfusion asymmetry indices (AIs), derived from the rCBV and rCBF of the bilateral mesial temporal lobes, were pared between the two groups. Results: In the control group, there were no statistically significant differences between the left and right sides in terms of rCBV (left 1.55 {+-} 0.32, right 1.57 {+-} 0.28) or rCBF (left 99.00 {+-} 24.61, right 100.38 {+-} 23.46) of the bilateral mesial temporal lobes. However, in the case group the ipsilateral rCBV and rCBF values (1.75 {+-} 0.64 and 96.35 {+-} 22.63, respectively) were markedly lower than those of the contralateral side (2.01 {+-} 0.79 and 108.56 {+-} 26.92; P < 0.05). Both the AI of the rCBV (AIrCBV; 13.03 {+-} 10.33) and the AI of the rCBF (AIrCBF; 11.24 {+-} 8.70) of the case group were significantly higher than that of the control group (AIrCBV 5.55 {+-} 3.74, AIrCBF 5.12 {+-} 3.48; P < 0.05). The epileptogenic foci of nine patients were correctly lateralized using the 95th percentile of the AIrCBV and AIrCBF of the control group as the normal upper limits. Conclusion: In

  12. Diagnosis of Spinal Lesions Using Heuristic and Pharmacokinetic Parameters Measured by Dynamic Contrast-Enhanced MRI.

    Science.gov (United States)

    Lang, Ning; Yuan, Huishu; Yu, Hon J; Su, Min-Ying

    2017-07-01

    This study aimed to evaluate the diagnostic performance of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in differentiation of four spinal lesions by using heuristic and pharmacokinetic parameters analyzed from DCE signal intensity time course. DCE-MRI of 62 subjects with confirmed myeloma (n = 9), metastatic cancer (n = 22), lymphoma (n = 7), and inflammatory tuberculosis (TB) (n = 24) in the spine were analyzed retrospectively. The region of interest was placed on strongly enhanced tissues. The DCE time course was categorized as the "wash-out," "plateau," or "persistent enhancement" pattern. The maximum enhancement, steepest wash-in enhancement, and wash-out slope using the signal intensity at 67 seconds after contrast injection as reference were measured. The Tofts 2-compartmental pharmacokinetic model was applied to obtain K trans and k ep . Pearson correlation between heuristic and pharmacokinetic parameters was evaluated, and receiver operating characteristic curve analysis was performed for pairwise group differentiation. The mean wash-out slope was -22% ± 10% for myeloma, 1% ± 0.4% for metastatic cancer, 3% ± 3% for lymphoma, and 7% ± 10% for TB, and it could significantly distinguish myeloma from metastasis (area under the curve [AUC] = 0.884), lymphoma (AUC = 1.0), and TB (AUC = 1.0) with P = .001, and distinguish metastasis from TB (AUC = 0.741) with P = .005. The k ep and wash-out slope were highly correlated (r = 0.92), and they showed a similar diagnostic performance. The K trans was significantly correlated with the maximum enhancement (r = 0.71) and the steepest wash-in enhancement (r = 0.85), but they had inferior diagnostic performance compared to the wash-out slope. DCE-MRI may provide additional diagnostic information, and a simple wash-out slope had the best diagnostic performance. The heuristic and pharmacokinetic parameters were highly correlated

  13. Comparison of neuroendocrine tumor detection and characterization using DOTATOC-PET in correlation with contrast enhanced CT and delayed contrast enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Giesel, F.L., E-mail: f.giesel@dkfz.de [Department of Nuclear Medicine, University Hospital Heidelberg, INF 400, 69120 Heidelberg (Germany); Kratochwil, C., E-mail: Clemens.kratochwil@t-online.de [Department of Nuclear Medicine, University Hospital Heidelberg, INF 400, 69120 Heidelberg (Germany); Mehndiratta, A., E-mail: dramit.mehndiratta@gmail.com [Keble College, Institute of Biomedical Engineering, University of Oxford, Parks Road, Oxford OX13PG (United Kingdom); Wulfert, S., E-mail: sarah.wulfert@googlemail.com [Department of Nuclear Medicine, University Hospital Heidelberg, INF 400, 69120 Heidelberg (Germany); Moltz, J.H., E-mail: Jan.Moltz@mevis.fraunhofer.de [Fraunhofer MEVIS, Bremen (Germany); Zechmann, C.M., E-mail: christian.zechmann@med.uni-heidelberg.de [Department of Nuclear Medicine, University Hospital Heidelberg, INF 400, 69120 Heidelberg (Germany); Kauczor, H.U., E-mail: Hans-ulrich.kauczor@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University of Heidelberg, INF 110, 69120 Heidelberg (Germany); Haberkorn, U., E-mail: uwe.haberkorn@med.uni-heidelberg.de [Department of Nuclear Medicine, University Hospital Heidelberg, INF 400, 69120 Heidelberg (Germany); Ley, S., E-mail: ley@gmx.de [Department of Diagnostic and Interventional Radiology, University of Heidelberg, INF 110, 69120 Heidelberg (Germany); Department of Medical Imaging, Toronto General Hospital (Canada)

    2012-10-15

    Purpose: We evaluated the rate of successful characterization of gastroenteropancreatic neuroendocrine tumors (NETs) present with an increased somatostatin receptor, comparing CE-CT with CE-MRI, each in correlation with DOTATOC-PET. Methods and materials: 8 patients with GEP-NET were imaged using CE-MRI (Gd-EOB-DTPA), CE-CT (Imeron 400) and DOTATOC-PET. Contrast-enhancement of normal liver-tissue and metastasis was quantified with ROI-technique. Tumor delineation was assessed with visual-score in blind-read-analysis by two experienced radiologists. Results: Out of 40 liver metastases in patients with NETs, all were detected by CE-MRI and the lesion extent could be adequately assessed, whereas CT failed to detect 20% of all metastases. The blind-read-score of CT in arterial and portal phase was median −0.65 and −1.4, respectively, and 2.7 for delayed-MRI. The quantitative ROI-analysis presented an improved contrast-enhancement-ratio with a median of 1.2, 1.6 and 3.3 for CE-CT arterial, portal-phase and delayed-MRI respectively. Conclusion: Late CE-MRI was superior to CE-CT in providing additionally morphologic characterization and exact lesion extension of hepatic metastases from neuroendocrine tumor detected with DOTATOC-PET. Therefore, late enhanced Gd-EOB-DTPA-MRI seems to be the adequate imaging modality for combination with DOTATOC-PET to provide complementary (macroscopic and molecular) tumor characterization in hepatic metastasized NETs.

  14. Optimum wavelet based masking for the contrast enhancement of medical images using enhanced cuckoo search algorithm.

    Science.gov (United States)

    Daniel, Ebenezer; Anitha, J

    2016-04-01

    Unsharp masking techniques are a prominent approach in contrast enhancement. Generalized masking formulation has static scale value selection, which limits the gain of contrast. In this paper, we propose an Optimum Wavelet Based Masking (OWBM) using Enhanced Cuckoo Search Algorithm (ECSA) for the contrast improvement of medical images. The ECSA can automatically adjust the ratio of nest rebuilding, using genetic operators such as adaptive crossover and mutation. First, the proposed contrast enhancement approach is validated quantitatively using Brain Web and MIAS database images. Later, the conventional nest rebuilding of cuckoo search optimization is modified using Adaptive Rebuilding of Worst Nests (ARWN). Experimental results are analyzed using various performance matrices, and our OWBM shows improved results as compared with other reported literature. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Automatic Contrast Enhancement of Brain MR Images Using Hierarchical Correlation Histogram Analysis.

    Science.gov (United States)

    Chen, Chiao-Min; Chen, Chih-Cheng; Wu, Ming-Chi; Horng, Gwoboa; Wu, Hsien-Chu; Hsueh, Shih-Hua; Ho, His-Yun

    Parkinson's disease is a progressive neurodegenerative disorder that has a higher probability of occurrence in middle-aged and older adults than in the young. With the use of a computer-aided diagnosis (CAD) system, abnormal cell regions can be identified, and this identification can help medical personnel to evaluate the chance of disease. This study proposes a hierarchical correlation histogram analysis based on the grayscale distribution degree of pixel intensity by constructing a correlation histogram, that can improves the adaptive contrast enhancement for specific objects. The proposed method produces significant results during contrast enhancement preprocessing and facilitates subsequent CAD processes, thereby reducing recognition time and improving accuracy. The experimental results show that the proposed method is superior to existing methods by using two estimation image quantitative methods of PSNR and average gradient values. Furthermore, the edge information pertaining to specific cells can effectively increase the accuracy of the results.

  16. Feature and Contrast Enhancement of Mammographic Image Based on Multiscale Analysis and Morphology

    Directory of Open Access Journals (Sweden)

    Shibin Wu

    2013-01-01

    Full Text Available A new algorithm for feature and contrast enhancement of mammographic images is proposed in this paper. The approach bases on multiscale transform and mathematical morphology. First of all, the Laplacian Gaussian pyramid operator is applied to transform the mammography into different scale subband images. In addition, the detail or high frequency subimages are equalized by contrast limited adaptive histogram equalization (CLAHE and low-pass subimages are processed by mathematical morphology. Finally, the enhanced image of feature and contrast is reconstructed from the Laplacian Gaussian pyramid coefficients modified at one or more levels by contrast limited adaptive histogram equalization and mathematical morphology, respectively. The enhanced image is processed by global nonlinear operator. The experimental results show that the presented algorithm is effective for feature and contrast enhancement of mammogram. The performance evaluation of the proposed algorithm is measured by contrast evaluation criterion for image, signal-noise-ratio (SNR, and contrast improvement index (CII.

  17. Feature and Contrast Enhancement of Mammographic Image Based on Multiscale Analysis and Morphology

    Science.gov (United States)

    Wu, Shibin; Xie, Yaoqin

    2013-01-01

    A new algorithm for feature and contrast enhancement of mammographic images is proposed in this paper. The approach bases on multiscale transform and mathematical morphology. First of all, the Laplacian Gaussian pyramid operator is applied to transform the mammography into different scale subband images. In addition, the detail or high frequency subimages are equalized by contrast limited adaptive histogram equalization (CLAHE) and low-pass subimages are processed by mathematical morphology. Finally, the enhanced image of feature and contrast is reconstructed from the Laplacian Gaussian pyramid coefficients modified at one or more levels by contrast limited adaptive histogram equalization and mathematical morphology, respectively. The enhanced image is processed by global nonlinear operator. The experimental results show that the presented algorithm is effective for feature and contrast enhancement of mammogram. The performance evaluation of the proposed algorithm is measured by contrast evaluation criterion for image, signal-noise-ratio (SNR), and contrast improvement index (CII). PMID:24416072

  18. Evaluating automated dynamic contrast enhanced wrist 3 T MRI in healthy volunteers: One-year longitudinal observational study

    Energy Technology Data Exchange (ETDEWEB)

    Rastogi, Anshul, E-mail: anshul.rastogi@bartshealth.nhs.uk [Kennedy Institute of Rheumatology, Imperial College London (United Kingdom); Kubassova, Olga, E-mail: olga@imageanalysis.org.uk [Image Analysis, Leeds (United Kingdom); Krasnosselskaia, Lada V., E-mail: solaguz@yahoo.com [Imaging Sciences Department, Imperial College London (United Kingdom); Lim, Adrian K.P., E-mail: a.lim@imperial.ac.uk [Department of Radiology, Imperial College Healthcare NHS Trust, London (United Kingdom); Satchithananda, Keshthra, E-mail: keshthra.satchithananda@imperial.nhs.uk [Department of Radiology, Imperial College Healthcare NHS Trust, London (United Kingdom); Boesen, Mikael, E-mail: mikael.boesen@gmail.com [Department of Radiology and the Parker Institute, Frederiksberg and Bispebjerg Hospitals (Denmark); Binks, Michael, E-mail: michael.h.binks@gsk.com [GlaxoSmithKline, Stevenage, SG1 2NY (United Kingdom); Hajnal, Joseph V., E-mail: jo.hajnal@kcl.ac.uk [Imaging Sciences Department, Imperial College London (United Kingdom); Taylor, Peter C., E-mail: peter.taylor@kennedy.ox.ac.uk [Kennedy Institute of Rheumatology, Imperial College London (United Kingdom)

    2013-08-15

    Rational and Objective: Dynamic contrast enhanced (DCE)-MRI has great potential to provide quantitative measure of inflammatory activity in rheumatoid arthritis. There is no current benchmark to establish the stability of signal in the joints of healthy subjects when imaged with DCE-MRI longitudinally, which is crucial so as to differentiate changes induced by treatment from the inherent variability of perfusion measures. The objective of this study was to test a pixel-by-pixel parametric map based approach for analysis of DCE-MRI (Dynamika) and to investigate the variability in signal characteristics over time in healthy controls using longitudinally acquired images. Materials and Methods: 10 healthy volunteers enrolled, dominant wrists were imaged with contrast enhanced 3T MRI at baseline, week 12, 24 and 52 and scored with RAMRIS, DCE-MRI was analysed using a novel quantification parametric map based approach. Radiographs were obtained at baseline and week 52 and scored using modified Sharp van der Heidje method. RAMRIS scores and dynamic MRI measures were correlated. Results: No erosions were seen on radiographs, whereas MRI showed erosion-like changes, low grade bone marrow oedema and low-moderate synovial enhancement. The DCE-MRI parameters were stable (baseline scores, variability) (mean ± st.dev); in whole wrist analysis, ME{sub mean} (1.3 ± 0.07, −0.08 ± 0.1 at week 24) and IRE{sub mean} (0.008 ± 0.004, −0.002 ± 0.005 at week 12 and 24). In the rough wrist ROI, ME{sub mean} (1.2 ± 0.07, 0.04 ± 0.02 at week 52) and IRE{sub mean} (0.001 ± 0.0008, 0.0006 ± 0.0009 at week 52) and precise wrist ROI, ME{sub mean} (1.2 ± 0.09, 0.04 ± 0.04 at week 52) and IRE{sub mean} (0.001 ± 0.0008, 0.0008 ± 0.001 at week 24 and 52). The Dynamic parameters obtained using fully automated analysis demonstrated strong, statistically significant correlations with RAMRIS synovitis scores. Conclusion: The study demonstrated that contrast enhancement does occur in

  19. Contrast-enhanced MR angiography of abdominal vessels: Is there still a role for angiography?

    Energy Technology Data Exchange (ETDEWEB)

    Vosshenrich, R.; Fischer, U. [Department of Radiology, Georg-August-Universitaet Goettingen (Germany)

    2002-01-01

    The purpose of this review article is to describe recent advantages in contrast-enhanced (CE) three-dimensional (3D) magnetic resonance angiography (MRA) in comparison with other vascular imaging techniques, and to discuss their current clinical applications for the imaging of abdominal vessels. Principles and technical considerations are presented and clinical applications are reviewed for different vascular diseases. In ruptured aortic aneurysms and acute dissections CT is the method of first choice. Contrast-enhanced 3D MRA can be well used for therapeutic planning and follow-up in patients with stable disease. A comprehensive MR examination including CE 3D MRA, MR urography and MR nephrogram has the potential to replace the conventional studies for the evaluation of renal vascular disease. It is an accurate method for imaging the origins of coeliac and superior mesenteric arteries, although the image resolution is too low for reliable assessment of the inferior mesenteric artery. Contrast-enhanced 3D MRA has emerged as the method of choice for studying the portal venous system in liver transplant recipients, in patients with portal hypertension and in cases with abdominal tumours for preoperative evaluation. Additional non-invasive flow measurements are useful in monitoring portal hypertension. The abdominal veins can be well imaged using unenhanced MR techniques. Imaging may be facilitated with intravascular contrast media. Contrast-enhanced 3D MRA can replace intra-arterial DSA for diagnosis, therapy planning and follow-up in patients with abdominal vascular disease. Catheter-based arteriography will still be used for interventional procedures such as percutaneous transluminal angioplasty, stent placement and embolisation. (orig.)

  20. Gadolinium Contrast Enhancement Improves Confidence in Diagnosing Recurrent Soft Tissue Sarcoma by MRI.

    Science.gov (United States)

    Chou, Shinn-Huey S; Hippe, Daniel S; Lee, Amie Y; Scherer, Kurt; Porrino, Jack A; Davidson, Darin J; Chew, Felix S; Ha, Alice S

    2017-05-01

    To determine how utilization of postgadolinium magnetic resonance imaging (MRI) influenced reader accuracy and confidence at identifying postoperative soft tissue sarcoma (STS) recurrence among readers with various levels of expertise. This retrospective study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. Postoperative MRI from 26 patients with prior STS resection (13 patients with confirmed recurrence, 13 without recurrence) was reviewed. Four blinded readers of varying expertise (radiology resident, fellow, attending, and orthopedic oncologist) initially evaluated only the precontrast images and rated each MRI for recurrence on a 5-point confidence scale. Assessment was repeated with the addition of contrast-enhanced sequences. Diagnostic accuracy based on confidence ratings was evaluated using the area under the receiver operating characteristic curve (AUC). Changes in confidence ratings were calculated using Wilcoxon signed-rank test. All readers demonstrated good diagnostic accuracy both with and without contrast-enhanced images (AUC >0.98 for each reader). When contrast-enhanced images were made available, the resident recorded improved confidence with both assigning (P = 0.031) and excluding recurrence (P = 0.006); the fellow showed improved confidence only with assigning recurrence (P = 0.015); and the surgeon showed improved confidence in excluding recurrence (P = 0.003). The addition of contrast-enhanced images did not significantly influence the diagnostic confidence of the attending radiologist. Diagnostic accuracy of MRI was excellent in evaluating postoperative STS recurrence, and reader confidence improved depending on expertise when postgadolinium imaging was included in the assessment. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  1. Digital contrast enhancement of (18)Fluorine-fluorodeoxyglucose positron emission tomography images in hepatocellular carcinoma.

    Science.gov (United States)

    Pandey, Anil Kumar; Sharma, Sanjay Kumar; Agarwal, Krishan Kant; Sharma, Punit; Bal, Chandrasekhar; Kumar, Rakesh

    2016-01-01

    The role of (18)fluorodeoxyglucose positron emission tomography (PET) is limited for detection of primary hepatocellular carcinoma (HCC) due to low contrast to the tumor, and normal hepatocytes (background). The aim of the present study was to improve the contrast between the tumor and background by standardizing the input parameters of a digital contrast enhancement technique. A transverse slice of PET image was adjusted for the best possible contrast, and saved in JPEG 2000 format. We processed this image with a contrast enhancement technique using 847 possible combinations of input parameters (threshold "m" and slope "e"). The input parameters which resulted in an image having a high value of 2(nd) order entropy, and edge content, and low value of absolute mean brightness error, and saturation evaluation metrics, were considered as standardized input parameters. The same process was repeated for total nine PET-computed tomography studies, thus analyzing 7623 images. The selected digital contrast enhancement technique increased the contrast between the HCC tumor and background. In seven out of nine images, the standardized input parameters "m" had values between 150 and 160, and for other two images values were 138 and 175, respectively. The value of slope "e" was 4 in 4 images, 3 in 3 images and 1 in 2 images. It was found that it is important to optimize the input parameters for the best possible contrast for each image; a particular value was not sufficient for all the HCC images. The use of above digital contrast enhancement technique improves the tumor to background ratio in PET images of HCC and appears to be useful. Further clinical validation of this finding is warranted.

  2. Diagnostic and prognostic values of contrast-enhanced ultrasound in breast cancer: a retrospective study

    OpenAIRE

    Zhao YX; Liu S.; Hu YB; Ge YY; Lv DM

    2017-01-01

    Yi-Xuan Zhao, Shuang Liu, Yan-Bing Hu, Yan-Yan Ge, Dong-Mei Lv Department of Ultrasound, Second Hospital, Jilin University, Changchun, People’s Republic of China Abstract: This study aimed to explore the diagnostic and prognostic values of contrast-enhanced ultrasound (CEUS) in breast cancer. Between September 2009 and October 2011, a total of 143 breast cancer patients and 161 healthy people were selected as case group and control group, respectively. After the identific...

  3. Fusion of contrast-enhanced breast MR and mammographic imaging data.

    Science.gov (United States)

    Behrenbruch, Christian P; Marias, Kostas; Armitage, Paul A; Yam, Margaret; Moore, Niall; English, Ruth E; Clarke, Jane; Brady, Michael

    2003-09-01

    Increasing use is being made of Gd-DTPA contrast-enhanced magnetic resonance imaging for breast cancer assessment since it provides 3D functional information via pharmacokinetic interaction between contrast agent and tumour vascularity, and because it is applicable to women of all ages as well as patients with post-operative scarring. Contrast-enhanced MRI (CE-MRI) is complementary to conventional X-ray mammography, since it is a relatively low-resolution functional counterpart of a comparatively high-resolution 2D structural representation. However, despite the additional information provided by MRI, mammography is still an extremely important diagnostic imaging modality, particularly for several common conditions such as ductal carcinoma in situ (DCIS) where it has been shown that there is a strong correlation between microcalcification clusters and malignancy. Pathological indicators such as calcifications and fine spiculations are not visible in CE-MRI and therefore there is clinical and diagnostic value in fusing the high-resolution structural information available from mammography with the functional data acquired from MRI imaging. This paper presents a novel data fusion technique whereby medial-lateral oblique (MLO) and cranial-caudal (CC) mammograms (2D data) are registered to 3D contrast-enhanced MRI volumes. We utilise a combination of pharmacokinetic modelling, projection geometry, wavelet-based landmark detection and thin-plate spline non-rigid 'warping' to transform the coordinates of regions of interest (ROIs) from the 2D mammograms to the spatial reference frame of the contrast-enhanced MRI volume. Of key importance is the use of a flexible wavelet-based feature extraction technique that enables feature correspondences to be robustly determined between the very different image characteristics of X-ray mammography and MRI. An evaluation of the fusion framework is demonstrated with a series of clinical cases and a total of 14 patient examples.

  4. The clinical use of contrast-enhanced ultrasound in the kidney

    OpenAIRE

    Tenant, Sean C; Gutteridge, Catherine M

    2016-01-01

    Traditional B-Mode and Doppler sonography have been the stalwart of renal tract imaging for many years, and indeed, are in daily use in most centres as the modality of choice for the initial assessment of renal pathology. However, traditional ultrasound scanning can be limited in its ability to accurately characterise renal pathology, and can be inaccurate at determining benign from malignant lesions. Contrast-enhanced ultrasound conveys many benefits, being safe (especially in patients with ...

  5. Diagnosis of subdural haematoma by computed axial tomography: use of xenon inhalation for contrast enhancement.

    Science.gov (United States)

    Zilkha, E; Kendall, B E; Loh, L; Hayward, R; Radue, E W; ingram, G S

    1978-01-01

    A subdural haematoma is described in which a definite computed tomographic (CT) scan diagnosis was made only after contrast enhancement had been achieved by the inhalation of xenon. The different types of enhancement obtained with iodide containing contrast media and with xenon are discussed. The use of xenon to obtain further information in conditions which are inadequately elucidated by conventional CT must be balanced against its anaesthetic effects and relatively high cost. Images PMID:650246

  6. Giant Congenital Intrapericardial Left Atrial Aneurysm Diagnosed by Contrast-Enhanced Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Taori, K.; Deshmukh, A.; Sanyal, R.; Saini, T.; Sheorain, V.; Rathod, J. [Government Medical College H, Nagpur (India). Dept. of Radiodiagnosis

    2006-07-15

    A left atrial aneurysm is a rare cardiac anomaly. The etiology is usually congenital, but it can also occur as an acquired pathology secondary to mitral valve disease or a degenerative process. We report a case which, on routine PA chest radiography, presented as cardiomegaly with a bulge on the left cardiac contour. Further evaluation by contrast-enhanced computed tomography proved it to be caused by a large left atrial aneurysm.

  7. Characterization of solitary pulmonary nodules: Use of washout characteristics at contrast-enhanced computed tomography

    OpenAIRE

    YE, XIAO-DAN; YE, JIAN-DING; YUAN, ZHENG; DONG, SHENG; XIAO, XIANG-SHENG

    2011-01-01

    The purpose of this study was to determine whether computed tomographic scans and attenuation measurements on contrast material-enhanced and non-enhanced computed tomographic scans could be used to characterize solitary pulmonary nodules and, in particular, to characterize these lesions using washout characteristics on contrast-enhanced computed tomography. A total of 63 patients (38 males, 25 females; age range, 21–80 years; mean age, 58±13.2 years) with pulmonary nodules revealed on contras...

  8. Three-Dimensional Characterization of Tissue-Engineered Constructs by Contrast-Enhanced Nanofocus Computed Tomography

    OpenAIRE

    Papantoniou, Ioannis; Sonnaert, Maarten; Geris, Liesbet; Luyten, Frank P.; Schrooten, Jan; Kerckhofs, Greet

    2014-01-01

    To successfully implement tissue-engineered (TE) constructs as part of a clinical therapy, it is necessary to develop quality control tools that will ensure accurate and consistent TE construct release specifications. Hence, advanced methods to monitor TE construct properties need to be further developed. In this study, we showed proof of concept for contrast-enhanced nanofocus computed tomography (CE-nano-CT) as a whole-construct imaging technique with a noninvasive potential that enables th...

  9. Spleen evaluation using contrast enhanced ultrasonography and Doppler in dogs with subclinical ehrlichiosis

    OpenAIRE

    Maronezi,M.C.; Feliciano,M.A.R.; Crivellenti,L.Z.; Borin-Crivellenti,S.; Silva,P.E.S.; Zampolo,C.; Pavan,L.; Gasser,B.; Simões,A.P.R.; Maciel,G.S.; Canola,J.C.; Vicente,W.R.R.

    2015-01-01

    The aim of this study was to evaluate the splenic parenchyma of dogs with subclinical ehrlichiosis using Doppler and contrast-enhanced ultrasonography and provide reference values for this organ in affected animals. Seventeen dogs naturally infected with E. canis were selected for this study. Splenic parenchyma echotexture and echogenicity, size and borders were determined by ultrasound scan. The vascular indices of the splenic artery were determined by Doppler. SonoVue, at 0.1mL per animal, ...

  10. [Evaluation of imaging parameters for T1 dynamic contrast enhanced MRI with fast spin-echo].

    Science.gov (United States)

    Kanazawa, Yuuki; Miyati, Tosiaki; Inoue, Yusuke; Sato, Osamu

    2007-10-20

    For the purpose of continual measurement of the T1 value using the FSE (fast spin-echo) sequence and evaluation of the hemodynamics, we assessed T1 values when the imaging parameters were changed. Moreover, with the imaging parameters derived from this study, dynamic contrast-enhanced MR imaging (MRI) was examined in prostatic disease. First, the T1 value before contrast agent injection was measured with imaging parameters that had different TR and fixed TE. Next, dynamic contrast-enhanced imaging data were acquired for the imaging parameters using TE and TR in the same way as before contrast agent injection, and the T1 value of the tissue at contrast enhancement was measured. In the phantom studies, the TSE imaging parameters with short TE, long TR, and few ETL were connected with the mixed sequence. In dynamic study of the prostate, the difference between normal prostate and prostate cancer became clearer with the time-relaxation rate curve than the time-signal curve. This method using TSE is able to evaluate in greater detail information on hemodynamics and to perform dynamic study with the spin-echo sequence in extensive tissues.

  11. Contrast-enhanced ultrsonography advanced and currrent status in abdominal imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chung Yong Eun; Kim Ki Whang [Dept. of Radiology, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-01-15

    n the field of contrast-enhanced ultrasonography (US), contrast agents are classified as either first- or second-generation agents depending on the gas within the microbubbles. In the case of first-generation contrast agents, a high-mechanical-index technique is used and only intermittent scanning is possible due to the early destruction of the microbubbles during the scanning. The use of second-generation contrast agents in a low-mechanical-index technique enables continuous scanning. Besides the detection and characterization of focal liver lesions, contrastenhanced US is helpful in the monitoring of radiofrequency ablation therapy and in the targeting step of an US-guided biopsy. Recently, there has been a demand for new criteria to evaluate the treatment response obtained using anti-angiogenic agents because morphologic criteria alone may not reflect the treatment response of the tumor and contrast-enhanced US can provide quantitative markers of tissue perfusion. In spite of the concerns related to its cost-effectiveness, contrast-enhanced US has the potential to be more widely used as a complimentary tool or to substitute the current imaging modalities in some occasions.

  12. [Application of dynamic contrast enhancement MRI and post-processing technique for diagnosis of breast cancer].

    Science.gov (United States)

    Peng, Kang-Qiang; Huang, Zi-Lin; Xie, Chuan-Miao; Chen, Lin; Ouyang, Yi; Zheng, Qing-Sheng; Zhang, Yan; He, Hao-Qiang; Wu, Pei-Hong

    2009-05-01

    Magnetic resonance imaging (MRI), an advanced non-invasive technique, is regarded as one of the potential modalities in the diagnosis of breast cancer. This study was to investigate the application of dynamic contrast enhancement MRI and 3D reconstruction images in diagnosing breast tumors. From May 2006 to September 2007, 30 patients with breast diseases were scanned with MRI in Sun Yat-sen University Cancer Center. MR plain scans, dynamic contrast enhancement scans were performed, and 3D reconstruction images were obtained. The normal breast tissue was used as control, and the maximum slope ratio was calculated. Forty-nine lesions were found in 30 patients, with an accuracy rate of 93.3%. MRI scan is an effective and specific modality for the diagnosis of breast diseases with high sensitivity and accuracy. Dynamic contrast enhancement MRI, image subtraction, time-signal intensity curve, 3D reconstruction images and the maximum slope ratio are helpful to make the correct diagnosis of breast lesions.

  13. Meta-analysis: Serum creatinine changes following contrast enhanced CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kooiman, Judith, E-mail: j.kooiman@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Pasha, Sharif M., E-mail: s.m.pasha@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Zondag, Wendy, E-mail: w.zondag@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Sijpkens, Yvo W.J., E-mail: ysijpens@bronovo.nl [Department of Nephrology, Bronovo Hospital, The Hague (Netherlands); Molen, Aart J. van der, E-mail: molen@lumc.nl [Department of Radiology, LUMC, Leiden (Netherlands); Huisman, Menno V., E-mail: m.v.huisman@lumc.nl [Department of Thrombosis and Haemostasis, LUMC, Leiden (Netherlands); Dekkers, Olaf M., E-mail: o.m.dekkers@lumc.nl [Department of Clinical Epidemiology and Department of Endocrinology, LUMC, Leiden (Netherlands)

    2012-10-15

    Purpose: Contrast induced nephropathy (CIN) is defined as a decrease in renal function following administration of contrast media. The aim of this meta-analysis was to asses the overall risk of CIN, chronic loss of kidney function and the need for renal replacement therapy (RRT) after intravenous contrast enhanced CT-scan. Secondly, we aimed to identify subgroups at increased risk for CIN. Materials and methods: A literature search in Pubmed, Medline, Embase and Cochrane databases was performed. Data extraction was carried out independently by two reviewers. Meta-analysis and meta-regression were performed using an exact likelihood approach. Results: Forty studies evaluating the incidence of CIN after CT were included. The pooled incidence of CIN was 6.4% (95% CI 5.0–8.1). The risk of RRT after CIN was low, 0.06% (95% CI 0.01–0.4). The decline in renal function persisted in 1.1% of patients (95% CI 0.6–2.1%). Patients with chronic kidney disease (odds ratio 2.26, p < 0.001) or diabetes mellitus (odds ratio 3.10, p < 0.001) were at increased risk for the development of CIN. Conclusion: CIN occurred in 6% of patients after contrast enhanced CT. In 1% of all patients undergoing contrast enhanced CT the decline in renal function persisted.

  14. Contrast-enhanced Magnetic Resonance Imaging in Pediatric Patients: Review and Recommendations for Current Practice

    Directory of Open Access Journals (Sweden)

    Ravi Bhargava

    2013-01-01

    Full Text Available Magnetic resonance imaging (MRI, frequently with contrast enhancement, is the preferred imaging modality for many indications in children. Practice varies widely between centers, reflecting the rapid pace of change and the need for further research. Guideline changes, for example on contrast-medium choice, require continued practice reappraisal. This article reviews recent developments in pediatric contrast-enhanced MRI and offers recommendations on current best practice. Nine leading pediatric radiologists from internationally recognized radiology centers convened at a consensus meeting in Bordeaux, France, to discuss applications of contrast-enhanced MRI across a range of indications in children. Review of the literature indicated that few published data provide guidance on best practice in pediatric MRI. Discussion among the experts concluded that MRI is preferred over ionizing-radiation modalities for many indications, with advantages in safety and efficacy. Awareness of age-specific adaptations in MRI technique can optimize image quality. Gadolinium-based contrast media are recommended for enhancing imaging quality. The choice of most appropriate contrast medium should be based on criteria of safety, tolerability, and efficacy, characterized in age-specific clinical trials and personal experience.

  15. Morphological image processing for quantitative shape analysis of biomedical structures: effective contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Kimori, Yoshitaka, E-mail: kimori@orion.ac.jp [National Institutes of Natural Sciences, 5-1 Higashiyama, Myodaiji, Okazaki, Aichi 444-8787 (Japan)

    2013-11-01

    A contrast enhancement approach utilizing a new type of mathematical morphology called rotational morphological processing is introduced. The method is quantitatively evaluated and then applied to some medical images. Image processing methods significantly contribute to visualization of images captured by biomedical modalities (such as mammography, X-ray computed tomography, magnetic resonance imaging, and light and electron microscopy). Quantitative interpretation of the deluge of complicated biomedical images, however, poses many research challenges, one of which is to enhance structural features that are scarcely perceptible to the human eye. This study introduces a contrast enhancement approach based on a new type of mathematical morphology called rotational morphological processing. The proposed method is applied to medical images for the enhancement of structural features. The effectiveness of the method is evaluated quantitatively by the contrast improvement ratio (CIR). The CIR of the proposed method is 12.1, versus 4.7 and 0.1 for two conventional contrast enhancement methods, clearly indicating the high contrasting capability of the method.

  16. The role of contrast-enhanced endoscopic ultrasound in pancreatic adenocarcinoma

    DEFF Research Database (Denmark)

    Saftoiu, Adrian; Vilmann, Peter; Bhutani, Manoop S

    2016-01-01

    Contrast-enhanced endoscopic ultrasound (CE-EUS) allows characterization, differentiation, and staging of focal pancreatic masses. The method has a high sensitivity and specificity for the diagnosis of pancreatic adenocarcinoma which is visualized as hypo-enhanced as compared to the rest of the p......Contrast-enhanced endoscopic ultrasound (CE-EUS) allows characterization, differentiation, and staging of focal pancreatic masses. The method has a high sensitivity and specificity for the diagnosis of pancreatic adenocarcinoma which is visualized as hypo-enhanced as compared to the rest...... of the parenchyma while chronic pancreatitis and neuroendocrine tumors are generally either iso-enhanced or hyper-enhanced. The development of contrast-enhanced low mechanical index harmonic imaging techniques used in real time during endoscopic ultrasound (EUS) allowed perfusion imaging and the quantification...... contrast agents for early detection, tridimensional and fusion techniques for enhanced staging and resectability assessment but also novel applications of perfusion imaging for monitoring ablative therapy, improved local detection through EUS-guided sampling of portal vein flow or enhanced drug delivery...

  17. Within-lesion differences in quantitative MRI parameters predict contrast enhancement in multiple sclerosis.

    Science.gov (United States)

    Jurcoane, Alina; Wagner, Marlies; Schmidt, Christoph; Mayer, Christoph; Gracien, Rene-Maxime; Hirschmann, Marc; Deichmann, Ralf; Volz, Steffen; Ziemann, Ulf; Hattingen, Elke

    2013-12-01

    To investigate the relationship between quantitative magnetic resonance imaging (qMRI) and contrast enhancement in multiple sclerosis (MS) lesions. We compared maps of T1 relaxation time, proton density (PD), and magnetization transfer ratio (MTR) between lesions with and without contrast enhancement as quantified by the amount of T1 shortening postcontrast agent (CA). In 17 patients with relapsing-remitting MS (RRMS), 15 with progressive MS (PMS), and 17 healthy controls, T1, PD, and MTR were measured at 3T and T1-mapping was repeated after CA administration. Manually drawn MS-lesions (3D-FLAIR) were labeled as enhancing if post-CA T1-shortening exceeded mean T1-shortening in normal-appearing white matter (NAWM) by at least 2 standard deviations. Precontrast T1, PD, and MTR were compared in enhancing lesions, nonenhancing lesions, NAWM, and gray matter. Precontrast T1, PD, and MTR differed significantly between enhancing and nonenhancing lesions in RRMS and PMS patients (all P T1 of gray matter differed significantly from RRMS and controls. Only MTR of gray matter differed between RRMS and controls. Contrast enhancement in MS quantified by relative T1 shortening may be predicted by precontrast abnormalities of T1, PD, and MTR and likely represents blood-brain barrier damage. Copyright © 2013 Wiley Periodicals, Inc.

  18. Leptomeningeal Contrast Enhancement Is Associated with Disability Progression and Grey Matter Atrophy in Multiple Sclerosis

    Directory of Open Access Journals (Sweden)

    Gleb Makshakov

    2017-01-01

    Full Text Available Leptomeningeal contrast enhancement (LMCE on magnetic resonance imaging (MRI is a newly recognized possible biomarker in multiple sclerosis (MS, associated with MS progression and cortical atrophy. In this study, we aimed to assess the prevalence of LMCE foci and their impact on neurodegeneration and disability. Materials. 54 patients with MS were included in the study. LMCE were detected with a 3 Tesla scanner on postcontrast fluid-attenuated inversion-recovery (FLAIR sequence. Expanded Disability Status Scale (EDSS score, number of relapses during 5 years from MS onset, and number of contrast-enhancing lesions on T1 weighted MRI were counted. Results. LMCE was detected in 41% (22/54 of patients. LMCE-positive patients had longer disease duration (p=0,0098 and higher EDSS score (p=0,039, but not a higher relapse rate (p=0,091. No association of LMCE with higher frequency of contrast-enhancing lesions on T1-weighted images was detected (p=0,3842. Analysis of covariates, adjusted for age, sex, and disease duration, revealed a significant effect of LMCE on the cortex volume (p=0.043, F=2.529, the total grey matter volume (p=0.043, F=2.54, and total ventricular volume (p=0.039, F=2.605. Conclusions. LMCE was shown to be an independent and significant biomarker of grey matter atrophy and disability in MS.

  19. Statistical comparison of dynamic contrast-enhanced MRI pharmacokinetic models in human breast cancer.

    Science.gov (United States)

    Li, Xia; Welch, E Brian; Chakravarthy, A Bapsi; Xu, Lei; Arlinghaus, Lori R; Farley, Jaime; Mayer, Ingrid A; Kelley, Mark C; Meszoely, Ingrid M; Means-Powell, Julie; Abramson, Vandana G; Grau, Ana M; Gore, John C; Yankeelov, Thomas E

    2012-07-01

    By fitting dynamic contrast-enhanced MRI data to an appropriate pharmacokinetic model, quantitative physiological parameters can be estimated. In this study, we compare four different models by applying four statistical measures to assess their ability to describe dynamic contrast-enhanced MRI data obtained in 28 human breast cancer patient sets: the chi-square test (χ(2)), Durbin-Watson statistic, Akaike information criterion, and Bayesian information criterion. The pharmacokinetic models include the fast exchange limit model with (FXL_v(p)) and without (FXL) a plasma component, and the fast and slow exchange regime models (FXR and SXR, respectively). The results show that the FXL_v(p) and FXR models yielded the smallest χ(2) in 45.64 and 47.53% of the voxels, respectively; they also had the smallest number of voxels showing serial correlation with 0.71 and 2.33%, respectively. The Akaike information criterion indicated that the FXL_v(p) and FXR models were preferred in 42.84 and 46.59% of the voxels, respectively. The Bayesian information criterion also indicated the FXL_v(p) and FXR models were preferred in 39.39 and 45.25% of the voxels, respectively. Thus, these four metrics indicate that the FXL_v(p) and the FXR models provide the most complete statistical description of dynamic contrast-enhanced MRI time courses for the patients selected in this study. Copyright © 2011 Wiley Periodicals, Inc.

  20. Contrast-enhanced ultrasonography to assess blood perfusion of skeletal muscles in normal dogs.

    Science.gov (United States)

    Oh, Juyeon; Jeon, Sunghoon; Choi, Jihye

    2015-07-01

    This study evaluated perfusion of skeletal muscle using contrast enhanced ultrasonography in humerus, radius, femur and tibia in normal dogs. Contrast enhanced ultrasonography for each region was performed after injecting 0.5 mL and 1 mL of contrast medium (SonoVue) in every dog. Blood perfusion was assessed quantitatively by measuring the peak intensity, time to the peak intensity and area under the curve from the time-intensity curve. Vascularization in skeletal muscle was qualitatively graded with a score of 0-3 according to the number of vascular signals. A parabolic shape of time-intensity curve was observed from muscles in normal dogs, and time to the peak intensity, the peak intensity and area under the curve of each muscle were not significantly different according to the appendicular regions examined and the dosage of contrast agent administered. This study reports that feasibility of contrast enhanced ultrasonography for assessment of the muscular perfusion in canine appendicular regions.

  1. Contrast-enhanced digital mammography (CEDM): phantom experiment and first clinical results

    Science.gov (United States)

    Marx, Christiane; Facius, Mirijam; Muller, Serge L.; Benali, Karim; Malich, Ansgar; Kaiser, Werner

    2002-05-01

    The introduction of the Full Field Digital Mammography (FFDM) opens the way to a large range of future advanced applications. Among them, Contrast Enhanced Digital Mammography (CEDM) could be a fast and less expensive alternative to Magnetic Resonance Imaging (MRI) for breast lesion characterization. In this work, we have investigated, first on phantom then on patients, the capability of a modified FFDM system to show the contrast enhancement of lesions after intra-venous injection of iodine. The uptake has been estimated from the difference between pre- and post-contrast images. Phantom results showed that 1) detectability thresholds of the contrast media were compatible with clinical conditions; 2) breast radiological thickness has a low impact on uptake detectability; 3) spatial and temporal analysis showed delayed margin contrast uptake of the simulated lesion and slow increase of contrast in the background. Preliminary results on patients have confirmed the phantom results and have shown a contrast uptake in all malignant lesions despite the observed patient motion artifacts, and some moderate signal variability. This study demonstrated the feasibility of the Contrast Enhanced Digital Mammography technique. Further investigations and clinical validations will have to be completed before it can be widely used in a daily routine practice.

  2. Differential diagnosis of solitary pulmonary inflammatory lesions and peripheral lung cancers with contrast-enhanced computed tomograph

    Energy Technology Data Exchange (ETDEWEB)

    Chu, Zhi-gang; Sheng, Bo; Liu, Meng-qi; Lv, Fa-jin; Li, Qi; Ouyang, Yu, E-mail: cyscitg@163.com [Hospital of Chongqing Medical University, Department of Radiology, Chongqing (China)

    2016-10-15

    Objectives: To clarify differences between solitary pulmonary inflammatory lesions and peripheral lung cancers with contrast-enhanced computed tomography. Methods: In total, 64 and 132 patients with solitary pulmonary inflammatory masses/nodules and peripheral lung cancers, respectively, were enrolled in this study. Their computed tomographic findings were summarized and compared retrospectively. Results: Compared with the peripheral lung cancers, the inflammatory lesions were located closer to the pleura (p<0.0001). The majority of the inflammatory lesions were patchy and oval-shaped (82.8%), whereas most of the tumors were lobulated (82.6%). Almost all the inflammatory cases were unclear (93.8%), whereas most of the tumors had speculated margins (72.7%). Computed tomography values were significantly higher for the inflammatory lesions than for the cancers (p<0.0001). More than half of the inflammatory lesions had defined necrosis (59.3%). Furthermore, 49.2% of the cancers enhanced inhomogeneously, but only 24.6% had ill-defined necrosis or cavities. The peripheral zones of 98.4% of the inflammatory lesions and 72.7% of the tumors were unclear, with peripheral scattered patches (92.2%) and beam-shaped opacity (66.7%) being the most common findings, respectively. Adjacent pleural thickening was more frequent for the inflammatory lesions than the cancers (95.3% vs. 21.1%, p<0.0001), whereas pleural indentation was found in 67.4% of the subjects with cancer. In addition, hilar (p=0.034) and mediastinal (p=0.003) lymphadenopathy were more commonly detected in the cancers than in the inflammatory cases. Conclusions: Contrast-enhanced computed tomography findings for pulmonary inflammatory lesions and peripheral lung cancers were significantly different in many aspects. Developing a comprehensive understanding of these differences is helpful for directing their management. (author)

  3. The complementary roles of dynamic contrast-enhanced MRI and {sup 18}F-fluorodeoxyglucose PET/CT for imaging of carotid atherosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Calcagno, Claudia; Ramachandran, Sarayu; Mani, Venkatesh; Millon, Antoine [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, One Gustave L. Levy Place, Box 1234, New York, NY (United States); Mount Sinai School of Medicine, Department of Radiology, New York, NY (United States); Izquierdo-Garcia, David [Harvard University - MIT - Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States); Rosenbaum, David [Hopital Pitie Salpetriere, Paris (France); Tawakol, Ahmed [Harvard Medical School and Massachusetts General Hospital, Boston, MA (United States); Woodward, Mark [University of Sydney, George Institute, Sydney (Australia); Bucerius, Jan [Maastricht University Medical Center, Department of Nuclear Medicine, Maastricht (Netherlands); Cardiovascular Research Institute Maastricht (CARIM), Maastricht (Netherlands); Rheinisch-Westfaelische Technische Hochschule Aachen, Department of Nuclear Medicine, Aachen (Germany); Moshier, Erin; Godbold, James [Mount Sinai School of Medicine, Biostatistics Shared Research Facility, New York, NY (United States); Kallend, David [F. Hoffmann-La Roche Ltd, Basel (Switzerland); Farkouh, Michael E. [Mount Sinai School of Medicine, Cardiovascular Institute, New York, NY (United States); Peter Munk Cardiac Centre and Li Ka Shing Knowledge Institute, Toronto (Canada); Fuster, Valentin [Mount Sinai School of Medicine, Cardiovascular Institute, New York, NY (United States); The Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid (Spain); Rudd, James H.F. [University of Cambridge, Division of Cardiovascular Medicine, Cambridge (United Kingdom); Fayad, Zahi A. [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, One Gustave L. Levy Place, Box 1234, New York, NY (United States); Mount Sinai School of Medicine, Department of Radiology, New York, NY (United States); Mount Sinai School of Medicine, Cardiovascular Institute, New York, NY (United States)

    2013-12-15

    Inflammation and neovascularization in vulnerable atherosclerotic plaques are key features for severe clinical events. Dynamic contrast-enhanced (DCE) MRI and FDG PET are two noninvasive imaging techniques capable of quantifying plaque neovascularization and inflammatory infiltrate, respectively. However, their mutual role in defining plaque vulnerability and their possible overlap has not been thoroughly investigated. We studied the relationship between DCE-MRI and {sup 18}F-FDG PET data from the carotid arteries of 40 subjects with coronary heart disease (CHD) or CHD risk equivalent, as a substudy of the dal-PLAQUE trial (NCT00655473). The dal-PLAQUE trial was a multicenter study that evaluated dalcetrapib, a cholesteryl ester transfer protein modulator. Subjects underwent anatomical MRI, DCE-MRI and {sup 18}F-FDG PET. Only baseline imaging and biomarker data (before randomization) from dal-PLAQUE were used as part of this substudy. Our primary goal was to evaluate the relationship between DCE-MRI and {sup 18}F-FDG PET data. As secondary endpoints, we evaluated the relationship between (a) PET data and whole-vessel anatomical MRI data, and (b) DCE-MRI and matching anatomical MRI data. All correlations were estimated using a mixed linear model. We found a significant inverse relationship between several perfusion indices by DCE-MRI and {sup 18}F-FDG uptake by PET. Regarding our secondary endpoints, there was a significant relationship between plaque burden measured by anatomical MRI with several perfusion indices by DCE-MRI and {sup 18}F-FDG uptake by PET. No relationship was found between plaque composition by anatomical MRI and DCE-MRI or {sup 18}F-FDG PET metrics. In this study we observed a significant, weak inverse relationship between inflammation measured as {sup 18}F-FDG uptake by PET and plaque perfusion by DCE-MRI. Our findings suggest that there may be a complex relationship between plaque inflammation and microvascularization during the different

  4. Automatic hyperspectral camera for latent fingerprint detection and contrast enhancement. Final report, September 2, 1998 - March 17, 1999

    Energy Technology Data Exchange (ETDEWEB)

    Paul Shnitser

    1999-06-01

    Physical Optics Corporation demonstrated the feasibility of the contrast enhancement of the latent fingerprint by portable hyperspectral imaging camera. The demonstrated non-contact technology is applicable for observation of the low contrast laser excited fluorescence from latent fingerprints as well as for the contrast enhancement of chemically processed fingerprints. Experiments were conducted with fingerprints on various types of substrates.

  5. Supra-aortic low-dose contrast-enhanced time-resolved magnetic resonance (MR) angiography at 3 T: comparison with time-of-flight MR angiography and high-resolution contrast-enhanced MR angiography.

    Science.gov (United States)

    Lee, Youn-Joo; Kim, Bum-soo; Koo, Ja-Sung; Kim, Bom-Yi; Jang, Jinhee; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin

    2015-06-01

    Low-dose, time-resolved, contrast-enhanced, magnetic resonance angiography (TR-CEMRA) has been described previously; however, a comparative study between low dose TR-CEMRA and time-of-flight MRA (TOF-MRA) in the diagnosis of supra-aortic arterial stenosis has not yet been published. To demonstrate the feasibility and effectiveness of low-dose TR-CEMRA compared with TOF-MRA, using high-resolution contrast-enhanced MRA (HR-CEMRA) as the reference standard. This prospective study consisted of 30 consecutive patients. All patients underwent TOF-MRA of the neck and circle of Willis and supra-aortic HR-CEMRA, followed by supra-aortic low-dose TR-CEMRA. Gadoterate meglumine (Gd-DOTA, Dotarem(®), Guerbet, Roissy CdG Cedex, France) was injected at a dose of 0.1 mmol/kg for HR-CEMRA, followed by a 0.03 mmol/kg bolus for low-dose TR-CEMRA. Three readers evaluated the assessibility and image quality, and then two readers classified each stenosis into the following categories: normal (0-30%), mild stenosis (31-50%), moderate (51-70%), severe (71-99%), and occlusion. TR-CEMRA and HR-CEMRA showed a greater number of assessable arterial segments than TOF-MRA (P < 0.01). For TR-CEMRA, 29 cases showed within or better than the diagnostic range, whereas all 30 cases were in the diagnostic range for TOF-MRA and HR-CEMRA. For evaluation of stenosis in a total of 743 arterial segments, both TR-CEMRA and TOF-MRA results agreed with those of HR-CEMRA in 729 segments (98.1%), with excellent inter-observer agreement of TR-CEMRA; stenosis was overestimated in nine segments (1.2%) and underestimated in five segments (0.7%). For diagnosis of stenosis using 30% as the cut-off value on HR-CEMRA, the sensitivity and specificity were 88.2% and 99.3%, respectively, for the TR-CEMRA procedure, versus 94.1% and 99.6%, respectively, for TOF-MRA. Low-dose TR-CEMRA is feasible and effective in the diagnosis of supra-aortic arterial stenosis, and could be more useful option than TOF-MRA. © The

  6. Apparent Diffusion Coefficient and Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Pancreatic Cancer: Characteristics and Correlation With Histopathologic Parameters.

    Science.gov (United States)

    Ma, Wanling; Li, Na; Zhao, Weiwei; Ren, Jing; Wei, Mengqi; Yang, Yong; Wang, Yingmei; Fu, Xin; Zhang, Zhuoli; Larson, Andrew C; Huan, Yi

    2016-01-01

    To clarify diffusion and perfusion abnormalities and evaluate correlation between apparent diffusion coefficient (ADC), MR perfusion and histopathologic parameters of pancreatic cancer (PC). Eighteen patients with PC underwent diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Parameters of DCE-MRI and ADC of cancer and non-cancerous tissue were compared. Correlation between the rate constant that represents transfer of contrast agent from the arterial blood into the extravascular extracellular space (K, volume of the extravascular extracellular space per unit volume of tissue (Ve), and ADC of PC and histopathologic parameters were analyzed. The rate constant that represents transfer of contrast agent from the extravascular extracellular space into blood plasma, K, tissue volume fraction occupied by vascular space, and ADC of PC were significantly lower than nontumoral pancreases. Ve of PC was significantly higher than that of nontumoral pancreas. Apparent diffusion coefficient and K values of PC were negatively correlated to fibrosis content and fibroblast activation protein staining score. Fibrosis content was positively correlated to Ve. Apparent diffusion coefficient values and parameters of DCE-MRI can differentiate PC from nontumoral pancreases. There are correlations between ADC, K, Ve, and fibrosis content of PC. Fibroblast activation protein staining score of PC is negatively correlated to ADC and K. Apparent diffusion coefficient, K, and Ve may be feasible to predict prognosis of PC.

  7. VEGFR-2 expression in HCC, dysplastic and regenerative liver nodules, and correlation with pre-biopsy Dynamic Contrast Enhanced CT.

    Science.gov (United States)

    Thaiss, W M; Kaufmann, S; Kloth, C; Nikolaou, K; Bösmüller, H; Horger, M

    2016-11-01

    To evaluate whether VEGFR-2-expression in hepatocellular carcinoma (HCC), dysplastic (DLN) and regenerative liver nodules (RLN) correlates with pre-histology, in vivo Dynamic Contrast Enhanced-Computed Tomography (DCE-CT) data as VEGFR-2-expression affects prognosis and therapeutic options. 34 patients (63.6±8.9years, 7 females) underwent liver biopsy or surgery due to suspected HCC or dysplastic nodules after DCE-CT between 2009 and 2015 with no previous chemo- or interventional therapy. Immunohistochemistry staining for VEGFR-2 was performed using Immunoreactive-Remmele-Stegner-Score (IRS) for quantification. A 128-row CT-scanner was used for DCE-CT with assessment of perfusion parameters blood flow (BF), blood volume (BV), arterial liver perfusion (ALP), portal venous perfusion (PVP), and hepatic perfusion index (HPI). Histology confirmed HCC (n=10), DLN (n=7) and RLN (n=34). Mean IRS for VEGFR-2 in HCCs was 9.1±3.0, 7.3±1.6 for DLN and 5.2±2.8 for RLN (p=0.0004 for HCC vs. RLN). Perfusion values varied significantly between all three groups for BF and HPI (pliver nodules. Perfusion markers blood flow, blood volume and hepatic perfusion index correlated well with VEGFR-2-immunostaining. This non-invasive discrimination between regenerative and dysplastic/HCC nodules might open new perspectives for diagnosis, therapy planning, and anti-VEGFR therapy monitoring. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Quantitative estimation of renal function with dynamic contrast-enhanced MRI using a modified two-compartment model.

    Directory of Open Access Journals (Sweden)

    Bin Chen

    Full Text Available To establish a simple two-compartment model for glomerular filtration rate (GFR and renal plasma flow (RPF estimations by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI.A total of eight New Zealand white rabbits were included in DCE-MRI. The two-compartment model was modified with the impulse residue function in this study. First, the reliability of GFR measurement of the proposed model was compared with other published models in Monte Carlo simulation at different noise levels. Then, functional parameters were estimated in six healthy rabbits to test the feasibility of the new model. Moreover, in order to investigate its validity of GFR estimation, two rabbits underwent acute ischemia surgical procedure in unilateral kidney before DCE-MRI, and pixel-wise measurements were implemented to detect the cortical GFR alterations between normal and abnormal kidneys.The lowest variability of GFR and RPF measurements were found in the proposed model in the comparison. Mean GFR was 3.03±1.1 ml/min and mean RPF was 2.64±0.5 ml/g/min in normal animals, which were in good agreement with the published values. Moreover, large GFR decline was found in dysfunction kidneys comparing to the contralateral control group.Results in our study demonstrate that measurement of renal kinetic parameters based on the proposed model is feasible and it has the ability to discriminate GFR changes in healthy and diseased kidneys.

  9. Radiofrequency ablation of renal tumours: diagnostic accuracy of contrast-enhanced ultrasound for early detection of residual tumour

    Energy Technology Data Exchange (ETDEWEB)

    Hoeffel, Christine [Service de Radiologie, CHU de Reims, Hopital Robert Debre, Pole d' imagerie, Reims Cedex (France); Pousset, Maud; Elie, Caroline [Universite Paris-Descartes, AP-HP, Departement de Biostatistiques, Hopital Necker, Paris Cedex 15 (France); Timsit, Marc-Olivier; Mejean, Arnaud [Universite Paris-Descartes, AP-HP, Service d' urologie, Hopital Necker, Paris Cedex 15 (France); Merran, Samuel [Federation mutualiste parisienne, Service d' imagerie medicale, Paris (France); Tranquart, Francois [Bracco Research, Plan les Ouates (Switzerland); Khairoune, Ahmed; Helenon, Olivier; Correas, Jean-Michel [Universite Paris-Descartes, AP-HP, Service de Radiologie Adultes, Hopital Necker, Paris Cedex 15 (France); Joly, Dominique [Universite Paris-Descartes, AP-HP, Service de Nephrologie, Hopital Necker, Paris Cedex 15 (France); Richard, Stephane [Service d' urologie, Hopital de Bicetre, Centre Pilote Tumeurs rares INCa, AP-HP, Le Kremlin-Bicetre (France); Hopital Necker, Service de Nephrologie, Paris Cedex 15 (France); Le Kremlin-Bicetre et Institut de Cancerologie Gustave Roussy, Genetique oncologique, CNRS FRE 2939, Faculte de medecine Paris-Sud, Villejuif (France)

    2010-08-15

    To evaluate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in the early detection of residual tumour after radiofrequency ablation (RFA) of renal tumours. Patients referred to our institution for RFA of renal tumours prospectively underwent CEUS and computed tomography (CT) or magnetic resonance imaging (MRI) before, within 1 day and 6 weeks after treatment. Identification of residual tumour was assessed by three blinded radiologists. Reference standard was CT/MRI performed at least 1 year after RFA. A total of 66 renal tumours in 43 patients (median age 62 years; range 44-71.5) were studied. Inter-reader agreement ({kappa} value) was 0.84 for CEUS. Prevalence of residual disease was 19%. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), respectively, were as follows: 64% [confidence interval (CI) 39-84], 98% [CI 91-100], 82% [CI 52-95] and 92% [CI 83-97] on 24-h CEUS; 79% [CI 52-92], 100% [CI 94-100], 100% [CI 74-100] and 95% [CI 87-100] on 6-week CEUS; 79% [CI 52-92], 95% [CI 86-98], 79% [CI 52-92] and 95% [CI 86-98] on 24-h CT/MRI; and 100% [CI 72-100], 98% [CI 90-100], 91% [CI 62-98] and 100% [CI 93-100] on 6-week CT/MRI. CEUS has high specificity for the early diagnosis of residual tumour after renal RFA. (orig.)

  10. Comparison between perfusion computed tomography and dynamic contrast-enhanced magnetic resonance imaging in assessing glioblastoma microvasculature.

    Science.gov (United States)

    Jia, Zhong Zheng; Shi, Wei; Shi, Jin Long; Shen, Dan Dan; Gu, Hong Mei; Zhou, Xue Jun

    2017-02-01

    Perfusion computed tomography (PCT) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) provide independent measurements of biomarkers related to tumor perfusion. The aim of this study was to compare the two techniques in assessing glioblastoma microvasculature. Twenty-five patients diagnosed with glioblastoma (14 males and 11 females; 51±11years old, ranging from 33 to 70 years) were includede in this prospective study. All patients underwent both PCT and DCE-MRI. Imaging was performed on a 256-slice CT scanner and a 3-T MRI system. PCT yielded permeability surface-area product (PS) using deconvolution physiological models; meanwhile, DCE-MRI determined volume transfer constant (Ktrans) using the Tofts-Kermode compartment model. All cases were submitted to surgical intervention, and CD105-microvascular density (CD105-MVD) was measured in each glioblastoma specimen. Then, Spearman's correlation coefficients and Bland-Altman plots were obtained for PS, Ktrans and CD105-MVD. Pmicrovasculature. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Lymphoma and inflammation in the orbit: Diagnostic performance with diffusion-weighted imaging and dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Sun, Bo; Song, Liyuan; Wang, Xinyan; Li, Jing; Xian, Junfang; Wang, Feifei; Tan, Pan

    2017-05-01

    To investigate the diagnostic performance of diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI), and the combination of both in the differential diagnosis of lymphoma and inflammation in the orbit. This retrospective study was approved by the Institutional Review Board and the informed consent requirement was waived. A total of 53 patients underwent preoperative 3T MRI. Parameters of DWI and DCE MRI were evaluated in these 30 patients with orbital lymphoma and 23 patients with orbital inflammation. The diagnostic performance was evaluated using receiver operating characteristic curve analysis. Apparent diffusion coefficient (ADC) values and parameters derived from DCE MRI of orbital lymphoma and orbital inflammation differed significantly (ADC, T max , contrast index [CI], enhancement ratio [ER], and washout ratio [WR]: P inflammation (P = 0.016 for reviewer 1; P = 0.001 for reviewer 2). The combination of DWI and DCE MRI can improve diagnostic performance in differentiating lymphoma from inflammation in the orbit compared with DWI alone. 3 J. MAGN. RESON. IMAGING 2017;45:1438-1445. © 2016 International Society for Magnetic Resonance in Medicine.

  12. Feasibility of iodine contrast enhanced CT-scan during a 18F-fluorodeoxyglucose Positron Emission Tomography

    Science.gov (United States)

    Houzard, C.; Tychyj, C.; Morelec, I.; Ricard, F.; Got, P.; Cotton, F.; Giammarile, F.; Maintas, D.

    2009-06-01

    OBJECTIVE: this prospective study evaluates the feasibility in current clinical practice of contrast enhanced CT-scan for diagnosis purpose, performed during 18FDG PET-CT study with a PET/CT tomography. METHOD: 25 patients underwent FDG imaging for lymphoma staging. The PET scan was done immediately after the usual low dose CT (lCT). A second CT scan was consequently acquired, by using classical diagnosis CT parameters (dCT) and iodinated contrast. For each patient, all CT attenuation correction (CTAC) PET images were visually compared. Density in Hounsfield units (HU) and maximum Standardized Uptake Value (SUVmax) were then measured on different organs and up to 5 specific lymphoma localizations (total of 294 measurements). RESULTS: Visual analysis was similar for the 2 modalities, without discordant interpretation for the pathologic sites. SUVmax means and standard deviation of each organ for lCTAC and dCTAC were comparable. The equation of the fitted multiple linear regression model was: dCT=0.0748191 + 1.17024*lCT (98.71%; p < 0.01). CONCLUSION: These first results allow the use of injected CT scan, before the PET scan acquisition for lymphoma staging with this PET-CT scan, not affected by the height atomic number and elevated density. A great benefit is therefore obtained on diagnostic, logistic and radioprotection purposes.

  13. Treatment response evaluation with three-dimensional contrast-enhanced ultrasound for liver cancer after local therapies

    Energy Technology Data Exchange (ETDEWEB)

    Xu Huixiong, E-mail: xuhuixiong@hotmail.co [Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, First Affiliated Hospital, Sun Yat-Sen University, 58th Zhongshan Road 2, Guangzhou 510080 (China); Lu Mingde, E-mail: lumd@21cn.co [Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, 58th Zhongshan Road 2, Guangzhou 510080 (China); Xie Xiaohua; Xie Xiaoyan [Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, First Affiliated Hospital, Sun Yat-Sen University, 58th Zhongshan Road 2, Guangzhou 510080 (China); Kuang Ming [Department of Hepatobiliary Surgery, First Affiliated Hospital, Sun Yat-Sen University, 58th Zhongshan Road 2, Guangzhou 510080 (China); Xu Zuofeng; Liu Guangjian; Wang Zhu; Chen Lida; Lin Manxia [Department of Medical Ultrasonics, Institute of Diagnostic and Interventional Ultrasound, First Affiliated Hospital, Sun Yat-Sen University, 58th Zhongshan Road 2, Guangzhou 510080 (China)

    2010-10-15

    Objective: To investigate the potential usefulness of three-dimensional contrast-enhanced ultrasound (3D-CEUS) in evaluating the treatment response for liver cancer after local therapies. Methods: A total of 107 lesions in 95 consecutive patients with liver cancer underwent local therapies and thereafter received low acoustic power 3D-CEUS examination. The LOGIQ 9 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The image quality of 3D-CEUS images was evaluated and the influence of 3D-CEUS to clinical outcome was investigated. Results: The image quality of 3D-CEUS was defined as high in 102 (102/107, 95.3%) lesions and common in 5 (5/107, 4.7%) lesions. 3D-CEUS did not change the diagnosis in any patient compared with 2D-CEUS. However, 3D-CEUS changed the management in 3 (2.8%) of 107 lesions, increased confidence but made no change in diagnosis in 85 (79.5%) lesions, added some information but did not change management or diagnosis in 15 (14.0%), and made no change in 4 (3.7%), respectively, in comparison with 2D-CEUS. Conclusion: 3D-CEUS enhances the diagnostic confidence in the majority of the patients and even changes the management in some patients. 3D-CEUS has potential usefulness in evaluating treatment response for liver cancer after local therapies.

  14. Liver Contrast-Enhanced Ultrasound Improves Detection of Liver Metastases in Patients with Pancreatic or Periampullary Cancer.

    Science.gov (United States)

    Taimr, Pavel; Jongerius, Vivian L; Pek, Chulja J; Krak, Nanda C; Hansen, Bettina E; Janssen, Harry L A; Metselaar, Herold J; van Eijck, Casper H J

    2015-12-01

    The aim of this study is to provide a diagnostic performance evaluation of contrast-enhanced ultrasonography (CEUS) in detecting liver metastases in patients with suspected of pancreatic or periampullary cancer. Computed tomography (CT) is often insufficient for detection of liver metastases, but their presence plays a crucial role in the choice of therapy. Eighty-nine patients with suspected pancreatic or periampullary cancer were included in this prospective study with retrospective analysis. Patients underwent an abdominal CT and CEUS. Fifteen patients had liver metastases. The CT sensitivity was 73.3% (11/15), the specificity 93.2% (69/74), the positive predictive value (PPV) 68.8% (11/16) and the negative predictive value (NPV) 94.6% (69/73). Based on CEUS, the sensitivity was 80% (12/15), specificity 98.6% (73/74), PPV 92.3% (12/13) and NPV 96.1% (73/76). CEUS improved characterization of liver lesions in patients with suspected pancreatic or periampullary cancer compared with CT. CEUS can better detect benign liver lesions and distinguish false-positive or indeterminate CT results. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. The quality of tumor size assessment by contrast-enhanced spectral mammography and the benefit of additional breast MRI.

    Science.gov (United States)

    Lobbes, Marc B I; Lalji, Ulrich C; Nelemans, Patty J; Houben, Ivo; Smidt, Marjolein L; Heuts, Esther; de Vries, Bart; Wildberger, Joachim E; Beets-Tan, Regina G

    2015-01-01

    Background - Contrast-enhanced spectral mammography (CESM) is a promising new breast imaging modality that is superior to conventional mammography for breast cancer detection. We aimed to evaluate correlation and agreement of tumor size measurements using CESM. As additional analysis, we evaluated whether measurements using an additional breast MRI exam would yield more accurate results. Methods - Between January 1(st) 2013 and April 1(st) 2014, 87 consecutive breast cancer cases that underwent CESM were collected and data on maximum tumor size measurements were gathered. In 57 cases, tumor size measurements were also available for breast MRI. Histopathological results of the surgical specimen served as gold standard in all cases. Results - The Pearson's correlation coefficients (PCC) of CESM versus histopathology and breast MRI versus histopathology were all >0.9, p1 cm between the two imaging modalities and histopathological results, we did not observe any advantage of performing an additional breast MRI after CESM in any of the cases. Conclusion - Quality of tumor size measurement using CESM is good and matches the quality of these measurement assessed by breast MRI. Additional measurements using breast MRI did not improve the quality of tumor size measurements.

  16. Contrast-enhanced cardiac MRI before coronary artery bypass surgery: impact of myocardial scar extent on bypass flow

    Energy Technology Data Exchange (ETDEWEB)

    Hunold, Peter; Schlosser, Thomas; Nassenstein, Kai; Barkhausen, Joerg [University Hospital Essen, University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Massoudy, Parwis; Boehm, Claudia; Knipp, Stephan; Thielmann, Matthias; Jakob, Heinz [West German Heart Center Essen, University of Duisburg-Essen, Department of Thoracic and Cardiovascular Surgery, Essen (Germany); Eggebrecht, Holger; Erbel, Raimund [West German Heart Center Essen, University of Duisburg-Essen, Department of Cardiology, Essen (Germany)

    2008-12-15

    The aim of the study was to relate the extent of myocardial late gadolinium enhancement (LGE) in cardiac MRI to intraoperative graft flow in patients undergoing coronary artery bypass graft (CABG) surgery. Thirty-three CAD patients underwent LGE MRI before surgery using an inversion-recovery GRE sequence (turboFLASH). Intraoperative graft flow in Doppler ultrasonography was compared with the scar extent in each coronary vessel territory. One hundred and fourteen grafts were established supplying 86 of the 99 vessel territories. A significant negative correlation was found between scar extent and graft flow (r = -0.4, p < 0.0001). Flow in grafts to territories with no or small subendocardial scar was significantly higher than in grafts to territories with broad nontransmural or transmural scar (75 {+-} 39 vs. 38 {+-} 26 cc min{sup -1}; p < 0.0001). In summary, the extent of myocardial scar as defined by contrast-enhanced MRI predicts coronary bypass graft flow. Beyond the probability of functional recovery, preoperative MRI might add value to surgery planning by predicting midterm bypass graft patency. (orig.)

  17. Quantitative Contrast-Enhanced Ultrasound Parameters in Crohn Disease: Their Role in Disease Activity Determination With Ultrasound.

    Science.gov (United States)

    Medellin-Kowalewski, Alexandra; Wilkens, Rune; Wilson, Alexandra; Ruan, Ji; Wilson, Stephanie R

    2016-01-01

    The primary objective of our study was to examine the association between contrast-enhanced ultrasound (CEUS) parameters and established gray-scale ultrasound with color Doppler imaging (CDI) for the determination of disease activity in patients with Crohn disease. Our secondary objective was to develop quantitative time-signal intensity curve thresholds for disease activity. One hundred twenty-seven patients with Crohn disease underwent ultrasound with CDI and CEUS. Reviewers graded wall thickness, inflammatory fat, and mural blood flow as showing remission or inflammation (mild, moderate, or severe). If both gray-scale ultrasound and CDI predicted equal levels of disease activity, the studies were considered concordant. If ultrasound images suggested active disease not supported by CDI findings, the ultrasound results for disease activity were indeterminate. Time-signal intensity curves from CEUS were acquired with calculation of peak enhancement (PE), and AUCs. Interobserver variation and associations between PE and ultrasound parameters were examined. Multiclass ROC analysis was used to develop CEUS thresholds for activity. Ninety-six (76%) studies were concordant, 19 of which showed severe disease, and 31 (24%) studies were indeterminate. Kappa analyses revealed good interobserver agreement on grades for CDI (κ = 0.76) and ultrasound (κ = 0.80) assessments. PE values on CEUS and wall thickness showed good association with the Spearman rank correlation coefficient for the entire population (ρ = 0.62, p disease activity level determinations.

  18. Intraprocedural contrast-enhanced ultrasound (CEUS) in liver percutaneous radiofrequency ablation: clinical impact and health technology assessment.

    Science.gov (United States)

    Mauri, Giovanni; Porazzi, Emanuele; Cova, Luca; Restelli, Umberto; Tondolo, Tania; Bonfanti, Marzia; Cerri, Anna; Ierace, Tiziana; Croce, Davide; Solbiati, Luigi

    2014-04-01

    To assess the clinical and the economic impacts of intraprocedural use of contrast-enhanced ultrasound (CEUS) in patients undergoing percutaneous radiofrequency ablation for small (impact, cost effectiveness, and budget, organisational and equity impacts were evaluated and compared with standard treatment without intraprocedural CEUS using the health technology assessment approach. Intraprocedural CEUS detected incomplete ablation in 34/93 (36.5 %) patients, who underwent additional treatment during the same session. At 24-h, complete ablation was found in 88/93 (94.6 %) patients. Thus, a second session of treatment was spared in 29/93 (31.1 %) patients. Cost-effectiveness analysis revealed an advantage for the use of intraprocedural CEUS in comparison with standard treatment (4,639 vs 6,592) with a 21.9 % reduction of the costs to treat the whole sample. Cost per patient for complete treatment was  4,609 versus  5,872 respectively. The introduction of intraprocedural CEUS resulted in a low organisational impact, and in a positive impact on equity Intraprocedural use of CEUS has a relevant clinical impact, reducing the number of re-treatments and the related costs per patient. • CEUS allows to immediately asses the result of ablation. • Intraprocedural CEUS decreases the number of second ablative sessions. • Intraprocedural CEUS may reduce cost per patient for complete treatment. • Use of intraprocedural CEUS may reduce hospital budget. • Its introduction has low organisational impact, and relevant impact on equity.

  19. Contrast-enhanced spectral mammography versus MRI: Initial results in the detection of breast cancer and assessment of tumour size

    Energy Technology Data Exchange (ETDEWEB)

    Fallenberg, E.M.; Renz, D.M. [Charite - Universitaetsmedizin Berlin, Clinic of Radiology, Berlin (Germany); Dromain, C. [Institut Gustave Roussy, Department of Radiology, Villejuif cedex (France); Diekmann, F. [St. Joseph-Stift Bremen, Department of Medical Imaging, Bremen (Germany); Engelken, F.; Krohn, M.; Singh, J.M.; Bick, U. [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany); Ingold-Heppner, B. [Charite - Universitaetsmedizin Berlin, Institute of Pathology, Berlin (Germany); Winzer, K.J. [Charite - Universitaetsmedizin Berlin, Breast Center, Department of Gynecology, Berlin (Germany)

    2014-01-15

    To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard. After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation. Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology. Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment. (orig.)

  20. An evaluation of the clinical diagnostic value of contrast-enhanced ultrasound combined with contrast-enhanced computed tomography in space-occupying lesions of the kidney.

    Science.gov (United States)

    Tian, Wen; Lu, Jianbo; Jiao, Dan; Cong, Zhibin

    2017-01-01

    There are a variety of space-occupying lesions of the kidney, and the benign lesions may be difficult to differentiate from the malignant ones. Therefore, an accurate judgment of the benign and malignant nature of the space-occupying lesions of the kidney is of high importance for the treatment and prognosis of these patients. To evaluate the diagnostic value of contrast-enhanced ultrasound (CEUS) combined with contrast-enhanced computed tomography (CECT) in space-occupying lesions of the kidney. Three hundred and sixty-seven patients with space-occupying lesions of the kidney (378 lesions) were examined by CEUS and CECT, respectively, then, a combined diagnosis was made after the combination of CEUS and CECT by a multidisciplinary team. The diagnoses from the three methods were compared. The pathological results were taken as the gold standard. The sensitivity, specificity, positive and negative predictive values and area under the receiver operating characteristic (ROC) curve were calculated for the three methods. Thus, the diagnostic value of the three methods was assessed. Of the 378 lesions examined, there were 301 malignant lesions and 77 benign lesions. The combined examination revealed 303 malignant lesions, with 9 benign lesions mistakenly diagnosed as malignant ones; thus, the misdiagnosis rate was 11.7%. By using the combined examination, 75 benign lesions were diagnosed, with the missed diagnosis of 7 malignant lesions, so the missed diagnosis rate was 2.3%. The sensitivity, specificity, positive and negative predictive values and area under the ROC curve with the combined examination of CEUS and CECT were 97.67% (0.950-0.989), 88.31% (0.785-0.942), 97.03% (0.942-0.985), 90.67% (0.811-0.958) and 0.930 (0.887-0.973), respectively. As compared with either CEUS or CECT alone, the difference in these indicators was of statistical significance (P<0.05). The combined examination greatly improved the sensitivity, specificity and accuracy of the diagnosis of

  1. Three-dimensional contrast enhanced ultrasound score and dynamic contrast-enhanced magnetic resonance imaging score in evaluating breast tumor angiogenesis: Correlation with biological factors

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Wan-Ru, E-mail: jiawanru@126.com [Department of Diagnostic Ultrasound, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Chai, Wei-Min, E-mail: chai_weimin@yahoo.com.cn [Department of Radiology, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Tang, Lei, E-mail: jessietang1003@163.com [Department of Diagnostic Ultrasound, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Wang, Yi, E-mail: xiatian.0602@163.com [Department of Diagnostic Ultrasound, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Fei, Xiao-Chun, E-mail: xcf0222@163.com [Department of Pathology, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Han, Bao-San, E-mail: hanbaosan@126.com [Department of Comprehensive Breast Health Center, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China); Chen, Man, E-mail: lucyjia1370@126.com [Department of Diagnostic Ultrasound, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, No. 197 Rui Jin 2nd Road, Shanghai 200025 (China)

    2014-07-15

    Objective: To explore the clinical value of three-dimensional contrast enhanced ultrasound (3D-CEUS) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) score systems in evaluating breast tumor angiogenesis by comparing their diagnostic efficacy and correlation with biological factors. Methods: 3D-CEUS was performed in 183 patients with breast tumors by Esaote Mylab90 with SonoVue (Bracco, Italy), DCE-MRI was performed on a dedicated breast magnetic resonance imaging (DBMRI) system (Aurora Dedicated Breast MRI Systems, USA) with a dedicated breast coil. 3D-CEUS and DCE-MRI score systems were created based on tumor perfusion and vascular characteristics. Microvessel density (MVD), vascular endothelial growth factor (VEGF) and matrix metalloproteinases (MMP-2, MMP-9) expression were measured by immunohistochemistry. Results: Pathological results showed 35 benign and 148 malignant breast tumors. MVD (P = 0.000, r = 0.76), VEGF (P = 0.000, r = 0.55), MMP-2 (P = 0.000, r = 0.39) and MMP-9 (P = 0.000, r = 0.41) expression were all significantly different between benignity and malignancy. Regarding 3D-CEUS 4 points as cutoff value, the sensitivity, specificity and accuracy were 85.1%, 94.3% and 86.9%, respectively, and correlated well with MVD (P = 0.000, r = 0.50), VEGF (P = 0.000, r = 0.50), MMP-2 (P = 0.000, r = 0.50) and MMP-9 (P = 0.000, r = 0.66). Taking DCE-MRI 5 points as cutoff value, the sensitivity, specificity and accuracy were 86.5%, 94.3% and 88.0%, respectively and also correlated well with MVD (P = 0.000, r = 0.52), VEGF (P = 0.000, r = 0.44), MMP-2 (P = 0.000, r = 0.42) and MMP-9 (P = 0.000, r = 0.35). Conclusions: 3D-CEUS score system displays inspiring diagnostic performance and good agreement with DCE-MRI scoring. Moreover, both score systems correlate well with MVD, VEGF, MMP-2 and MMP-9 expression, and thus have great potentials in tumor angiogenesis evaluation.

  2. Application of contrast-enhanced ultrasound in the diagnosis of solid pancreatic lesions—A comparison of conventional ultrasound and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Zhihui, E-mail: fanzhihui_1026@163.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Li, Ying, E-mail: 18901033676@126.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Radiology, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yan, Kun, E-mail: ydbz@sina.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Wu, Wei, E-mail: wuwei@163.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yin, Shanshan, E-mail: yshshmd@yahoo.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yang, Wei, E-mail: weiwei02032001@gmail.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Xing, Baocai, E-mail: xinbaocai88@sina.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Hepatic Biliary and Pancreatic Surgery, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); and others

    2013-09-15

    Objective: To explore the diagnostic value of contrast-enhanced ultrasound (CEUS) by comparison with conventional ultrasound (US) and contrast-enhanced CT (CECT) in solid pancreatic lesions. Method: Ninety patients with solid pancreatic focal lesions were enrolled, including 36 cases of pancreatic carcinoma, 28 cases of pancreatitis, 6 cases of pancreatic neuroendocrine tumor, 12 cases of solid pseudopapillary tumor of the pancreas, 6 cases of pancreatic metastases, 1 case of cavernous hemolymphangioma and 1 case of lymphoma. US and CEUS were applied respectively for the diagnosis of a total of 90 cases of solid pancreatic lesions. The diagnostic results were scored on a 5-point scale. Results of CEUS were compared with CECT. Results: (1) 3-score cases (undetermined) diagnosed by CEUS were obviously fewer than that of US, while the number of 1-score (definitely benign) and 5-score (definitely malignant) cases diagnosed by CEUS was significantly more than that of US. There was a significant difference in the distribution of final scores using the two methods (p < 0.001). The overall diagnostic accuracies of the 90 cases for CEUS and US were 83.33% and 44.44%, respectively, which indicated an obvious advantage for CEUS (p < 0.001). (2) The diagnostic consistency among three ultrasound doctors: the kappa values calculated for US were 0.537, 0.444 and 0.525, compared with 0.748, 0.645 and 0.795 for CEUS. The interobserver agreement for CEUS was higher than that for US. (3) The sensitivity, specificity and accuracy of the diagnosis of pancreatic carcinoma with CEUS and CECT were 91.7% and 97.2%, 87.0% and 88.9%, and 88.9% and 92.2%, respectively, while for the diagnosis of pancreatitis, the corresponding indices were 82.1% and 67.9%, 91.9% and 100%, and 88.9% and 90%, respectively, showing no significant differences (p > 0.05). Conclusion: CEUS has obvious superiority over conventional US in the general diagnostic accuracy of solid pancreatic lesions and in the

  3. [Value of three-dimensional contrast-enhanced magnetic resonance angiography in the diagnosis of mesenteric arteriosclerosis].

    Science.gov (United States)

    Yang, Pei-qin; Zheng, Xiao-lin; Fan, Xian-biao; Quan, Hai-ying

    2009-09-01

    To assess the clinical value of three-dimensional contrast-enhanced magnetic resonance angiography (3D-CE-MRA) in the diagnosis of mesenteric arteriosclerosis. 3D-CE-MRA of the mesenteric arteries was performed in 21 patients with 23 healthy subjects as the control. After 3D image reconstruction and maxi intense projection, and the abnormalities of the mesenteric arteries were observed and analyzed. The diameter and number of the arterial branches were compared between the patients and the control subjects. All the 21 patients suffered arteriosclerosis in the arteries other than the mesenteric arteries. On 3D-CE-MRA, mesenteric arteriosclerosis was characterized by thinning of the arterial trunk, luminal stenosis, irregular arterial margins and homo- or heterogeneous thickening of vascular walls. Multiple filling defects were found in the mesenteric artery lumens with reduced second order branches, which showed rigid lining with dashed line appearance or disappeared in some cases. The inferior mesenteric arteries were seen in only 2 patients. The diameters of superior and inferior mesenteric arteries were 3.8-/+0.32 mm and 1.20-/+0.12 mm in the patients, significantly smaller than those of in the control subjects (6.51-/+1.01 mm and 2.90-/+0.90 mm, respectively, Parteriosclerosis and secondary intestinal changes, and provides a useful means for the diagnosis and assisting the therapy of mesenteric arteriosclerosis.

  4. Usefulness of contrast-enhanced ultrasound for detection of carotid plaque ulceration in patients with symptomatic carotid atherosclerosis.

    Science.gov (United States)

    ten Kate, Gerrit L; van Dijk, Anouk C; van den Oord, Stijn C H; Hussain, Burhan; Verhagen, Hence J M; Sijbrands, Eric J G; van der Steen, Antonius F W; van der Lugt, Aad; Schinkel, Arend F L

    2013-07-15

    Previous data have indicated that carotid plaque ulceration is a strong predictor of cerebrovascular events. Standard ultrasound and color Doppler ultrasound (CDUS) scans have poor diagnostic accuracy for the detection of carotid plaque ulceration. The aim of the present prospective study was to assess the value of contrast-enhanced ultrasound (CEUS) scans for the detection of carotid plaque ulceration. The Institutional Ethics Committee approved the study protocol, and all patients provided informed consent. The patients had symptomatic stenosis of the internal carotid artery and underwent carotid computed tomographic angiography as part of their clinical evaluation. All patients underwent a CDUS examination in conjunction with CEUS. Carotid plaque ulceration was defined as the presence of ≥1 disruptions in the plaque-lumen border ≥1 × 1 mm. Carotid computed tomographic angiography was used as reference technique. The study population consisted of 20 patients (mean age 64 ± 9 years, 80% men), and 39 carotid arteries were included in the present analysis. Computed tomographic angiography demonstrated that the plaque surface was smooth in 15 (38%), irregular in 7 (18%) and ulcerated in 17 (44%) carotid arteries. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CDUS for the detection of ulceration was 29%, 73%, 54%, 46%, and 57%, respectively. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of CEUS for the detection of ulceration was 88%, 59%, 72%, 63%, and 87%, respectively. CEUS had superior sensitivity and diagnostic accuracy for the assessment of carotid plaque ulceration compared with CDUS. CEUS improved the intrareader and inter-reader variability for the assessment of carotid plaque ulceration compared with CDUS. In conclusion, CEUS could be an additional method for the detection of carotid plaque ulceration. The role of CDUS for the assessment of

  5. Dynamic multidetector CT and non-contrast-enhanced MR for right adrenal vein imaging: comparison with catheter venography in adrenal venous sampling

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideki; Seiji, Kazumasa; Kawabata, Masahiro; Satani, Nozomi; Matsuura, Tomonori; Tominaga, Junya; Takase, Kei [Tohoku University Hospital, Department of Diagnostic Radiology, Sendai (Japan); Omata, Kei; Ono, Yoshikiyo; Iwakura, Yoshitsugu; Morimoto, Ryo; Kudo, Masataka; Satoh, Fumitoshi; Ito, Sadayoshi [Tohoku University Hospital, Division of Nephrology, Endocrinology and Vascular Medicine, Sendai (Japan)

    2016-03-15

    To evaluate visualization of the right adrenal vein (RAV) with multidetector CT and non-contrast-enhanced MR imaging in patients with primary aldosteronism. A total of 125 patients (67 men) scheduled for adrenal venous sampling (AVS) were included. Dynamic 64-detector-row CT and balanced steady-state free precession-based non-contrast-enhanced 3-T MR imaging were performed. RAV visualization based on a four-point score was documented. Both anatomical location and variation on cross-sectional imaging were evaluated, and the findings were compared with catheter venography as the gold standard. The RAV was visualized in 93.2 % by CT and 84.8 % by MR imaging (p = 0.02). Positive predictive values of RAV visualization were 100 % for CT and 95.2 % for MR imaging. Imaging score was significantly higher in CT than MR imaging (p < 0.01). The RAV formed a common trunk with an accessory hepatic vein in 16 % of patients. The RAV orifice level on cross-sectional imaging was concordant with catheter venography within the range of 1/3 vertebral height in >70 % of subjects. Success rate of AVS was 99.2 %. Dynamic CT is a reliable way to map the RAV prior to AVS. Non-contrast-enhanced MR imaging is an alternative when there is a risk of complication from contrast media or radiation exposure. (orig.)

  6. Non-mass-like enhancement on contrast-enhanced breast MR imaging: lesion characterization using combination of dynamic contrast-enhanced and diffusion-weighted MR images.

    Science.gov (United States)

    Yabuuchi, Hidetake; Matsuo, Yoshio; Kamitani, Takeshi; Setoguchi, Taro; Okafuji, Takashi; Soeda, Hiroyasu; Sakai, Shuji; Hatakenaka, Masamitsu; Kubo, Makoto; Tokunaga, Eriko; Yamamoto, Hidetaka; Honda, Hiroshi

    2010-07-01

    To evaluate the diagnostic accuracy of a combination of dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted MR imaging (DWI) in characterization of lesions showing non-mass-like enhancement on breast MR imaging and to find the strongest discriminators between carcinoma and benignancy. We analyzed consecutive MR images in 45 lesions showing non-mass like enhancement in 41 patients. We analyzed lesion size, distribution, internal enhancement, kinetic curve pattern, and apparent diffusion coefficient (ADC) values. We applied univariate and multivariate analyses to find the strongest indicators for malignancy. In a validation study, 22 non-mass-like enhancement lesions in 21 patients were examined. We calculated diagnostic accuracy when we presume category 4b, 4c, and 5 lesions as malignant or high to moderate suspicion for malignancy, and category 4a and 3 as low suspicion for malignancy or benign. Segmental distribution (P=0.018), clumped internal enhancement (P=0.005), and ADC less than 1.3 x 10(-3) mm(2)/s (P=0.047) were the strongest MR indicators of malignancy. In a validation study, sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 87% (13/15), 86% (6/7), 93% (13/14), 75% (6/8) and 86% (19/22), respectively. The combination of DCE-MRI and DWI showed high diagnostic accuracy in characterization of non-mass-like enhancement lesions on breast MR images. Copyright 2009 Elsevier Ireland Ltd. All rights reserved.

  7. Bipolar radiofrequency ablation for liver tumors: comparison of contrast-enhanced ultrasound with contrast-enhanced MRI/CT in the posttreatment imaging evaluation.

    Science.gov (United States)

    Bo, Xiao-Wan; Xu, Hui-Xiong; Sun, Li-Ping; Zheng, Shu-Guang; Guo, Le-Hang; Lu, Feng; Wu, Jian; Xu, Xiao-Hong

    2014-01-01

    The aim of the study was to assess the role of contrast-enhanced ultrasound (CEUS) in treatment response evaluation after percutaneous bipolar radiofrequency ablation (BRFA) for liver tumors. From May 2012 to May 2014, 39 patients with 73 tumors were treated by BRFA. One month after the treatment, CEUS and CEMRI/CECT were conducted to evaluate the treatment response. The results of CEUS were compared with CEMRI/CECT. Of the 73 tumors ablated, eight (11.0%) were found to have residual viable tumor tissue and 65 (89.0%) were successfully ablated based on CEMRI/CECT within 1-month after ablation. CEUS detected seven of the eight residual tumors and 63 of 65 completely ablated tumors. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CEUS were 87.5% (7/8), 96.9% (63/65), 77.8% (7/9), 98.4% (63/64) and 95.9% (70/73), respectively. The complete ablation (CR) rates for the tumors ≤ 3.0 cm, 3.1-5.0 cm, and >5.0 cm were 96.6% (58/60), 63.6% (7/11), and 0% (0/2), respectively (Ptechnique of percutaneous ablation for liver tumors and CEUS can be used to assess its therapeutic effect accurately.

  8. Assessing lung function using contrast-enhanced dual-energy computed tomography for potential applications in radiation therapy.

    Science.gov (United States)

    Lapointe, Andréanne; Bahig, Houda; Blais, Danis; Bouchard, Hugo; Filion, Édith; Carrier, Jean-François; Bedwani, Stéphane

    2017-10-01

    There is an increasing interest in the evaluation of lung function from physiological images in radiation therapy treatment planning to reduce the extent of postradiation toxicities. The purpose of this work was to retrieve reliable functional information from contrast-enhanced dual-energy computed tomography (DECT) for new applications in radiation therapy. The functional information obtained by DECT is also compared with other methods using single-energy CT (SECT) and single-photon emission computed tomography (SPECT) with CT. The differential function between left and right lung, as well as between lobes is computed for all methods. Five lung cancer patients were retrospectively selected for this study; each underwent a SPECT/CT scan and a contrast-injected DECT scan, using 100 and 140 Sn kVp. The DECT images are postprocessed into iodine concentration maps, which are further used to determine the perfused blood volume. These maps are calculated in two steps: (a) a DECT stoichiometric calibration adapted to the presence of iodine and followed by (b) a two-material decomposition technique. The functional information from SECT is assumed proportional to the HU numbers from a mixed CT image. The functional data from SPECT/CT are considered proportional to the number of counts. A radiation oncologist segmented the entire lung volume into five lobes on both mixed CT images and low-dose CT images from SPECT/CT to allow a regional comparison. The differential function for each subvolume is computed relative to the entire lung volume. The differential function per lobe derived from SPECT/CT correlates strongly with DECT (Pearson's coefficient r = 0.91) and moderately with SECT (r = 0.46). The differential function for the left lung shows a mean difference of 7% between SPECT/CT and DECT; and 17% between SPECT/CT and SECT. The presence of nonfunctional areas, such as localized emphysema or a lung tumor, is reflected by an intensity drop in the iodine concentration maps

  9. Subjectivity

    Directory of Open Access Journals (Sweden)

    Jesús Vega Encabo

    2015-11-01

    Full Text Available In this paper, I claim that subjectivity is a way of being that is constituted through a set of practices in which the self is subject to the dangers of fictionalizing and plotting her life and self-image. I examine some ways of becoming subject through narratives and through theatrical performance before others. Through these practices, a real and active subjectivity is revealed, capable of self-knowledge and self-transformation. 

  10. Temporomandibular joint (TMJ) pain revisited with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI).

    Science.gov (United States)

    Tasali, N; Cubuk, R; Aricak, M; Ozarar, M; Saydam, B; Nur, H; Tuncbilek, N

    2012-03-01

    We aimed to assess the contrast enhancement patterns of the retrodiscal tissue with dynamic contrast-enhanced MR imaging (DCE-MRI) with respect to different temporomandibular joint disc pathologies. Additionally, we questioned the relationship between the temporomandibular joint (TMJ) pain and the contrast enhancement pattern of the retrodiscal tissue regardless of the TMJ disc position. 52 joints of 26 patients (4 males and 22 females) who have pain in at least at one of their TMJ were included in this study. For the qualitative analysis, the joints were divided into four groups in terms of their disc positions: normal (1), partially displaced with or without reduction (2), totally dislocated with reduction (3) and totally dislocated without reduction (4). Besides, two different joint groups were constituted, namely the painful group and painless group according to the clinical findings without taking the TMJ disc positions into account. Quantitative analyses were made by means of measuring signal intensity ratios (SI) ratio at the retrodiscal tissue (from internal side and external side of the each joint) using DCE-MRI and these measurements were analyzed with paired samples t test to define the difference between the measurements. At the second stage, the time-dependent arithmetical mean values of the SI ratios were calculated for each joint group and significant differences between the groups were questioned using analysis of variance (ANOVA) test. Besides, painful and painless groups which were classified on the basis of the clinical data were compared according to the mean SI ratios found for each joint and the significant differences between these two groups were assessed by means of Student's T test. The results were assessed in 95% confidence interval where the significance level was pjoints with partial displacement. Another significant difference was found between the average time versus SI ratio curves of the four groups. In consequence of the

  11. Myocardial blood flow estimates from dynamic contrast-enhanced magnetic resonance imaging: three quantitative methods

    Science.gov (United States)

    Borrazzo, Cristian; Galea, Nicola; Pacilio, Massimiliano; Altabella, Luisa; Preziosi, Enrico; Carnì, Marco; Ciolina, Federica; Vullo, Francesco; Francone, Marco; Catalano, Carlo; Carbone, Iacopo

    2018-02-01

    Dynamic contrast-enhanced cardiovascular magnetic resonance imaging can be used to quantitatively assess the myocardial blood flow (MBF), recovering the tissue impulse response function for the transit of a gadolinium bolus through the myocardium. Several deconvolution techniques are available, using various models for the impulse response. The method of choice may influence the results, producing differences that have not been deeply investigated yet. Three methods for quantifying myocardial perfusion have been compared: Fermi function modelling (FFM), the Tofts model (TM) and the gamma function model (GF), with the latter traditionally used in brain perfusion MRI. Thirty human subjects were studied at rest as well as under cold pressor test stress (submerging hands in ice-cold water), and a single bolus of gadolinium weighing 0.1  ±  0.05 mmol kg‑1 was injected. Perfusion estimate differences between the methods were analysed by paired comparisons with Student’s t-test, linear regression analysis, and Bland–Altman plots, as well as also using the two-way ANOVA, considering the MBF values of all patients grouped according to two categories: calculation method and rest/stress conditions. Perfusion estimates obtained by various methods in both rest and stress conditions were not significantly different, and were in good agreement with the literature. The results obtained during the first-pass transit time (20 s) yielded p-values in the range 0.20–0.28 for Student’s t-test, linear regression analysis slopes between 0.98–1.03, and R values between 0.92–1.01. From the Bland–Altman plots, the paired comparisons yielded a bias (and a 95% CI)—expressed as ml/min/g—for FFM versus TM, ‑0.01 (‑0.20, 0.17) or 0.02 (‑0.49, 0.52) at rest or under stress respectively, for FFM versus GF, ‑0.05 (‑0.29, 0.20) or  ‑0.07 (‑0.55, 0.41) at rest or under stress, and for TM versus GF, ‑0.03 (‑0.30, 0.24) or  ‑0.09 (‑0.43, 0

  12. Anatomical noise in contrast-enhanced digital mammography. Part II. Dual-energy imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Melissa L.; Yaffe, Martin J. [Sunnybrook Research Institute, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada and Department of Medical Biophysics, University of Toronto, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada); Mainprize, James G. [Sunnybrook Research Institute, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada); Carton, Ann-Katherine; Saab-Puong, Sylvie; Iordache, Răzvan; Muller, Serge [GE Healthcare, 283 rue de la Minière, Buc 78530 (France); Jong, Roberta A. [Breast Imaging, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada); Dromain, Clarisse [Department of Radiology, Institut Gustave Roussy, 39 rue Camille Desmoulin, Villejuif 94805 (France)

    2013-08-15

    Purpose: Dual-energy (DE) contrast-enhanced digital mammography (CEDM) uses an iodinated contrast agent in combination with digital mammography (DM) to evaluate lesions on the basis of tumor angiogenesis. In DE imaging, low-energy (LE) and high-energy (HE) images are acquired after contrast administration and their logarithms are subtracted to cancel the appearance of normal breast tissue. Often there is incomplete signal cancellation in the subtracted images, creating a background “clutter” that can impair lesion detection. This is the second component of a two-part report on anatomical noise in CEDM. In Part I the authors characterized the anatomical noise for single-energy (SE) temporal subtraction CEDM by a power law, with model parameters α and β. In this work the authors quantify the anatomical noise in DE CEDM clinical images and compare this with the noise in SE CEDM. The influence on the anatomical noise of the presence of iodine in the breast, the timing of imaging postcontrast administration, and the x-ray energy used for acquisition are each evaluated.Methods: The power law parameters, α and β, were measured from unprocessed LE and HE images and from DE subtracted images to quantify the anatomical noise. A total of 98 DE CEDM cases acquired in a previous clinical pilot study were assessed. Conventional DM images from 75 of the women were evaluated for comparison with DE CEDM. The influence of the imaging technique on anatomical noise was determined from an analysis of differences between the power law parameters as measured in DM, LE, HE, and DE subtracted images for each subject.Results: In DE CEDM, weighted image subtraction lowers β to about 1.1 from 3.2 and 3.1 in LE and HE unprocessed images, respectively. The presence of iodine has a small but significant effect in LE images, reducing β by about 0.07 compared to DM, with α unchanged. Increasing the x-ray energy, from that typical in DM to a HE beam, significantly decreases α by about 2

  13. Anatomical noise in contrast-enhanced digital mammography. Part II. Dual-energy imaging.

    Science.gov (United States)

    Hill, Melissa L; Mainprize, James G; Carton, Ann-Katherine; Saab-Puong, Sylvie; Iordache, Razvan; Muller, Serge; Jong, Roberta A; Dromain, Clarisse; Yaffe, Martin J

    2013-08-01

    Dual-energy (DE) contrast-enhanced digital mammography (CEDM) uses an iodinated contrast agent in combination with digital mammography (DM) to evaluate lesions on the basis of tumor angiogenesis. In DE imaging, low-energy (LE) and high-energy (HE) images are acquired after contrast administration and their logarithms are subtracted to cancel the appearance of normal breast tissue. Often there is incomplete signal cancellation in the subtracted images, creating a background "clutter" that can impair lesion detection. This is the second component of a two-part report on anatomical noise in CEDM. In Part I the authors characterized the anatomical noise for single-energy (SE) temporal subtraction CEDM by a power law, with model parameters α and β. In this work the authors quantify the anatomical noise in DE CEDM clinical images and compare this with the noise in SE CEDM. The influence on the anatomical noise of the presence of iodine in the breast, the timing of imaging postcontrast administration, and the x-ray energy used for acquisition are each evaluated. The power law parameters, α and β, were measured from unprocessed LE and HE images and from DE subtracted images to quantify the anatomical noise. A total of 98 DE CEDM cases acquired in a previous clinical pilot study were assessed. Conventional DM images from 75 of the women were evaluated for comparison with DE CEDM. The influence of the imaging technique on anatomical noise was determined from an analysis of differences between the power law parameters as measured in DM, LE, HE, and DE subtracted images for each subject. In DE CEDM, weighted image subtraction lowers β to about 1.1 from 3.2 and 3.1 in LE and HE unprocessed images, respectively. The presence of iodine has a small but significant effect in LE images, reducing β by about 0.07 compared to DM, with α unchanged. Increasing the x-ray energy, from that typical in DM to a HE beam, significantly decreases α by about 2×10(-5) mm2, and lowers

  14. Fully automated segmentation of whole breast using dynamic programming in dynamic contrast enhanced MR images.

    Science.gov (United States)

    Jiang, Luan; Hu, Xiaoxin; Xiao, Qin; Gu, Yajia; Li, Qiang

    2017-06-01

    Amount of fibroglandular tissue (FGT) and level of background parenchymal enhancement (BPE) in breast dynamic contrast enhanced magnetic resonance images (DCE-MRI) are suggested as strong indices for assessing breast cancer risk. Whole breast segmentation is the first important task for quantitative analysis of FGT and BPE in three-dimensional (3-D) DCE-MRI. The purpose of this study is to develop and evaluate a fully automated technique for accurate segmentation of the whole breast in 3-D fat-suppressed DCE-MRI. The whole breast segmentation consisted of two major steps, i.e., the delineation of chest wall line and breast skin line. First, a sectional dynamic programming method was employed to trace the upper and/or lower boundaries of the chest wall by use of the positive and/or negative gradient within a band along the chest wall in each 2-D slice. Second, another dynamic programming was applied to delineate the skin-air boundary slice-by-slice based on the saturated gradient of the enhanced image obtained with the prior statistical distribution of gray levels of the breast skin line. Starting from the central slice, these two steps employed a Gaussian function to limit the search range of boundaries in adjacent slices based on the continuity of chest wall line and breast skin line. Finally, local breast skin line detection was applied around armpit to complete the whole breast segmentation. The method was validated with a representative dataset of 100 3-D breast DCE-MRI scans through objective quantification and subjective evaluation. The MR scans in the dataset were acquired with four MR scanners in five spatial resolutions. The cases were assessed with four breast density ratings by radiologists based on Breast Imaging Reporting and Data System (BI-RADS) of American College of Radiology. Our segmentation algorithm achieved a Dice volume overlap measure of 95.8 ± 1.2% and volume difference measure of 8.4 ± 2.4% between the automatically and manually

  15. Local gray level S-curve transformation - A generalized contrast enhancement technique for medical images.

    Science.gov (United States)

    Gandhamal, Akash; Talbar, Sanjay; Gajre, Suhas; Hani, Ahmad Fadzil M; Kumar, Dileep

    2017-04-01

    Most medical images suffer from inadequate contrast and brightness, which leads to blurred or weak edges (low contrast) between adjacent tissues resulting in poor segmentation and errors in classification of tissues. Thus, contrast enhancement to improve visual information is extremely important in the development of computational approaches for obtaining quantitative measurements from medical images. In this research, a contrast enhancement algorithm that applies gray-level S-curve transformation technique locally in medical images obtained from various modalities is investigated. The S-curve transformation is an extended gray level transformation technique that results into a curve similar to a sigmoid function through a pixel to pixel transformation. This curve essentially increases the difference between minimum and maximum gray values and the image gradient, locally thereby, strengthening edges between adjacent tissues. The performance of the proposed technique is determined by measuring several parameters namely, edge content (improvement in image gradient), enhancement measure (degree of contrast enhancement), absolute mean brightness error (luminance distortion caused by the enhancement), and feature similarity index measure (preservation of the original image features). Based on medical image datasets comprising 1937 images from various modalities such as ultrasound, mammograms, fluorescent images, fundus, X-ray radiographs and MR images, it is found that the local gray-level S-curve transformation outperforms existing techniques in terms of improved contrast and brightness, resulting in clear and strong edges between adjacent tissues. The proposed technique can be used as a preprocessing tool for effective segmentation and classification of tissue structures in medical images. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Contrast-enhanced multislice pneumo-CT-cystography in the evaluation of urinary bladder neoplasms

    Energy Technology Data Exchange (ETDEWEB)

    Scardapane, Arnaldo [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy)], E-mail: scardapane@aruba.it; Pagliarulo, Vincenzo [Institute of Urology, University Hospital ' Policlinico' , Bari (Italy); Ianora, Amato A. Stabile [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy); Pagliarulo, Arcangelo [Institute of Urology, University Hospital ' Policlinico' , Bari (Italy); Angelelli, Giuseppe [Institute of Diagnostic Radiology, University Hospital ' Policlinico' , Bari (Italy)

    2008-05-15

    Purpose: To evaluate the accuracy of contrast-enhanced multislice CT (MSCT) in the study of urothelial tumors after distension of the bladder with air. Materials and methods: We evaluated 43 consecutive patients with endoscopically proven bladder lesions. After air distension of the bladder, unenhanced pelvic and enhanced abdomino-pelvic scans were obtained with the following protocol: thickness 2.5 mm x 4 mm, increment 1 mm, scan delay 40'' and 7-10 min. For each patient we considered the number, size, aspect (papillary or sessile) and contrast enhancement of lesions. Ureteral involvement and the presence of synchronous lesions in the excretory scan were also evaluated. MPR and virtual endoscopy images were reviewed in all cases. Results: Bladder lesions were visualized in 39/43 cases. Compared to conventional cystoscopy, MSCT recognized single lesions in 31/33 patients, two lesions in 4/6, three in 2/2 and more than five foci in 2/2 patients. A papillary aspect was described in 44 cases while 11 lesions were sessile. Conventional Cystoscopy recognized six more lesions as compared with MSCT (four flat and two small papillary lesions). The detection rate for protruding lesions was 100% (52/52) for lesions > 5 mm and 60% (3/5%) for lesions < 5 mm. In four patients hydronephrosis was present, while in one case a synchronous lesion was evident in the renal pelvis. Conclusion: Contrast-enhanced MSCT with air distension of the urinary bladder is a safe and complete investigation to evaluate the local stage of bladder cancer and to evaluate the ureteral extension of the tumor, as well as the presence of synchronous lesions.

  17. Ileal Crohn disease: mural microvascularity quantified with contrast-enhanced US correlates with disease activity.

    Science.gov (United States)

    De Franco, Antonio; Di Veronica, Alessandra; Armuzzi, Alessandro; Roberto, Italia; Marzo, Manuela; De Pascalis, Barbara; De Vitis, Italo; Papa, Alfredo; Bock, Enrico; Danza, Francesco M; Bonomo, Lorenzo; Guidi, Luisa

    2012-02-01

    To quantitatively assess microvascular activation in the thickened ileal walls of patients with Crohn disease (CD) by using contrast-enhanced ultrasonography (US) and evaluate its correlation with widely used indexes of CD activity. This prospective study was approved by the ethics committee, and written informed consent was obtained from all patients. The authors examined 54 consecutively enrolled patients (mean age, 35.29 years; age range, 18-69 years; 39 men, 15 women) with endoscopically confirmed CD of the terminal ileum. Ileal wall segments thicker than 3 mm were examined with low-mechanical-index contrast-enhanced US and a second-generation US contrast agent. The authors analyzed software-plotted time-enhancement intensity curves to determine the maximum peak intensity (MPI) and wash-in slope coefficient (β) and evaluated their correlation with (a) the composite index of CD activity (CICDA), (b) the CD activity index (CDAI), and (c) the simplified endoscopic score for CD (SES-CD, evaluated in 37 patients) for the terminal ileum. Statistical analysis was performed with the Mann-Whitney test, Spearman rank test, and receiver operating characteristic (ROC) analysis. MPI and β coefficients were significantly increased in the 36 patients with a CICDA indicative of active disease (P<.0001 for both), the 33 patients with a CDAI of at least 150 (P<.032 and P<.0074, respectively), and the 26 patients with an SES-CD of at least 1 (P<.0001 and P<.002, respectively). ROC analysis revealed accurate identification (compared with CICDA) of active CD with an MPI threshold of 24 video intensity (VI) (sensitivity, 97%; specificity, 83%) and a β coefficient of 4.5 VI/sec (sensitivity, 86%; specificity, 83%). Contrast-enhanced US of the ileal wall is a promising method for objective, reproducible assessment of disease activity in patients with ileal CD. © RSNA, 2011

  18. Predicting IDH mutation status of intrahepatic cholangiocarcinomas based on contrast-enhanced CT features.

    Science.gov (United States)

    Zhu, Yong; Chen, Jun; Kong, Weiwei; Mao, Liang; Kong, Wentao; Zhou, Qun; Zhou, Zhengyang; Zhu, Bin; Wang, Zhongqiu; He, Jian; Qiu, Yudong

    2018-01-01

    To explore the difference in contrast-enhanced computed tomography (CT) features of intrahepatic cholangiocarcinomas (ICCs) with different isocitrate dehydrogenase (IDH) mutation status. Clinicopathological and contrast-enhanced CT features of 78 patients with 78 ICCs were retrospectively analysed and compared based on IDH mutation status. There were 11 ICCs with IDH mutation (11/78, 14.1%) and 67 ICCs without IDH mutation (67/78, 85.9%). IDH-mutated ICCs showed intratumoral artery more often than IDH-wild ICCs (p = 0.023). Most ICCs with IDH mutation showed rim and internal enhancement (10/11, 90.9%), while ICCs without IDH mutation often appeared diffuse (26/67, 38.8%) or with no enhancement (4/67, 6.0%) in the arterial phase (p = 0.009). IDH-mutated ICCs showed significantly higher CT values, enhancement degrees and enhancement ratios in arterial and portal venous phases than IDH-wild ICCs (all p IDH mutation, with an area under the curve of 0.798 (p = 0.002). ICCs with and without IDH mutation differed significantly in arterial enhancement mode, and the tumour enhancement degree on multiphase contrast-enhanced CT was helpful in predicting IDH mutation status. • IDH mutation occurred frequently in ICCs. • ICCs with and without IDH mutation differed significantly in arterial enhancement mode. • ICCs with IDH mutation enhanced more than those without IDH mutation. • Enhancement ratio and tumour CT value can predict IDH mutation status.

  19. Contrast-Enhanced Subharmonic and Harmonic Ultrasound of Renal Masses Undergoing Percutaneous Cryoablation.

    Science.gov (United States)

    Eisenbrey, John R; Shaw, Colette M; Lyshchik, Andrej; Machado, Priscilla; Lallas, Costas D; Trabulsi, Edouard J; Merton, Daniel A; Fox, Traci B; Liu, Ji-Bin; Brown, Daniel B; Forsberg, Flemming

    2015-07-01

    The objective of this study was to evaluate and compare contrast-enhanced subharmonic and harmonic ultrasound as tools for characterizing solid renal masses and monitoring their response to cryoablation therapy. Sixteen patients undergoing percutaneous ablation of a renal mass provided informed consent to undergo ultrasound examinations the morning before and approximately 4 months after cryoablation. Ultrasound contrast parameters during pretreatment imaging were compared to biopsy results obtained during ablation (n = 13). Posttreatment changes were evaluated by a radiologist and compared to contrast-enhanced magnetic resonance imaging (MRI)/computed tomography (CT) follow-up. All masses initially showed heterogeneous enhancement with both subharmonic and harmonic ultrasound. Early contrast washout in the mass relative to the cortex was observed in 6 of 9 malignant and 0 of 4 benign lesions in subharmonic mode and 8 of 9 malignant and 1 of 4 benign lesions in harmonic imaging. In cases where the lesion was adequately visualized at follow-up (n = 12), subharmonic and harmonic ultrasound showed accuracies of 83% and 75%, respectively, in predicting treatment outcome. Although harmonic imaging showed less overall error, no significant differences (P > .29) in ablation cavity volumes were observed between MRI/CT and either contrast-imaging mode. Subharmonic and harmonic contrast-enhanced ultrasound may be a safe and accurate imaging alternative for characterizing renal masses and evaluating their response to cryoablation therapy. Although subharmonic imaging was more accurate in detecting effective cryoablation, harmonic imaging was superior in quantifying ablation cavity volumes. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  20. CT findings in autoimmune pancreatitis: assessment using multiphase contrast-enhanced multisection CT

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, K., E-mail: Kojiro@med.nagoya-u.ac.j [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Itoh, S. [Department of Radiology, Nagoya Hirokoji Clinic, Nagoya (Japan); Nagasaka, T. [Departments of Medical Technology, Nagoya University School of Health Science, Nagoya (Japan); Ogawa, H.; Ota, T.; Naganawa, S. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2010-09-15

    Aim: To assess the spectrum of findings using multiphase contrast-enhanced computed tomography (CT) in patients with autoimmune pancreatitis (AIP). Materials and methods: Fifty patients (four female and 46 male, mean age 65 years) were retrospectively identified from consecutive patients with abnormal CT findings of the pancreas and negative work-up for known causes. These patients had at least one finding supporting the diagnosis of AIP: serological abnormality, histopathological abnormality, or response to steroid. Two radiologists evaluated multiphase contrast-enhanced CT images in consensus. Results: The pancreas showed diffuse enlargement (n = 16; 32%), focal enlargement (n = 18; 36%), or no enlargement (n = 16; 32%). Forty-nine (98%) patients showed abnormal contrast enhancement in the affected pancreatic parenchyma, including hypoattenuation during the pancreatic phase (n = 45; 90%) and hyperattenuation during the delayed phase (n = 39; 87%). The following findings were also seen in the pancreas: a capsule-like rim (n = 24; 48%); no visualization of the main pancreatic duct lumen (n = 48; 96%); ductal enhancement (n = 26; 52%); upstream dilatation of the main pancreatic duct (n = 27; 54%); upstream atrophy of the pancreatic parenchyma (n = 27; 54%); calcification (n = 7; 14%); and cysts (n = 5; 10%). Forty-two (84%) patients showed one or more of the following extrapancreatic findings: biliary duct or gallbladder abnormality (n = 40; 80%); peripancreatic (n = 8; 16%) or para-aortic (n = 10; 20%) soft-tissue proliferation; and renal involvement (n = 15; 30%). Conclusion: Patients with AIP presented with a variety of CT findings in the pancreas and the extrapancreatic organs. The present study highlights pancreatic ductal enhancement in a subset of patients with AIP.

  1. Diagnostic Accuracy of Dynamic Contrast Enhanced Magnetic Resonance Imaging in Characterizing Lung Masses

    Science.gov (United States)

    Inan, Nagihan; Arslan, Arzu; Donmez, Muhammed; Sarisoy, Hasan Tahsin

    2016-01-01

    Background Imaging plays a critical role not only in the detection, but also in the characterization of lung masses as benign or malignant. Objectives To determine the diagnostic accuracy of dynamic magnetic resonance imaging (MRI) in the differential diagnosis of benign and malignant lung masses. Patients and Methods Ninety-four masses were included in this prospective study. Five dynamic series of T1-weighted spoiled gradient echo (FFE) images were obtained, followed by a T1-weighted FFE sequence in the late phase (5th minutes). Contrast enhancement patterns in the early (25th second) and late (5th minute) phase images were evaluated. For the quantitative evaluation, signal intensity (SI)-time curves were obtained and the maximum relative enhancement, wash-in rate, and time-to-peak enhancement of masses in both groups were calculated. Results The early phase contrast enhancement patterns were homogeneous in 78.2% of the benign masses, while heterogeneous in 74.4% of the malignant tumors. On the late phase images, 70.8% of the benign masses showed homogeneous enhancement, while most of the malignant masses showed heterogeneous enhancement (82.4%). During the first pass, the maximum relative enhancement and wash-in rate values of malignant masses were significantly higher than those of the benign masses (P = 0.03 and 0.04, respectively). The cutoff value at 15% yielded a sensitivity of 85.4%, specificity of 61.2%, and positive predictive value of 68.7% for the maximum relative enhancement. Conclusion Contrast enhancement patterns and SI-time curve analysis of MRI are helpful in the differential diagnosis of benign and malignant lung masses. PMID:27703654

  2. Automatic segmentation and quantification of the cardiac structures from non-contrast-enhanced cardiac CT scans

    Science.gov (United States)

    Shahzad, Rahil; Bos, Daniel; Budde, Ricardo P. J.; Pellikaan, Karlijn; Niessen, Wiro J.; van der Lugt, Aad; van Walsum, Theo

    2017-05-01

    Early structural changes to the heart, including the chambers and the coronary arteries, provide important information on pre-clinical heart disease like cardiac failure. Currently, contrast-enhanced cardiac computed tomography angiography (CCTA) is the preferred modality for the visualization of the cardiac chambers and the coronaries. In clinical practice not every patient undergoes a CCTA scan; many patients receive only a non-contrast-enhanced calcium scoring CT scan (CTCS), which has less radiation dose and does not require the administration of contrast agent. Quantifying cardiac structures in such images is challenging, as they lack the contrast present in CCTA scans. Such quantification would however be relevant, as it enables population based studies with only a CTCS scan. The purpose of this work is therefore to investigate the feasibility of automatic segmentation and quantification of cardiac structures viz whole heart, left atrium, left ventricle, right atrium, right ventricle and aortic root from CTCS scans. A fully automatic multi-atlas-based segmentation approach is used to segment the cardiac structures. Results show that the segmentation overlap between the automatic method and that of the reference standard have a Dice similarity coefficient of 0.91 on average for the cardiac chambers. The mean surface-to-surface distance error over all the cardiac structures is 1.4+/- 1.7 mm. The automatically obtained cardiac chamber volumes using the CTCS scans have an excellent correlation when compared to the volumes in corresponding CCTA scans, a Pearson correlation coefficient (R) of 0.95 is obtained. Our fully automatic method enables large-scale assessment of cardiac structures on non-contrast-enhanced CT scans.

  3. Deep learning enables reduced gadolinium dose for contrast-enhanced brain MRI.

    Science.gov (United States)

    Gong, Enhao; Pauly, John M; Wintermark, Max; Zaharchuk, Greg

    2018-02-13

    There are concerns over gadolinium deposition from gadolinium-based contrast agents (GBCA) administration. To reduce gadolinium dose in contrast-enhanced brain MRI using a deep learning method. Retrospective, crossover. Sixty patients receiving clinically indicated contrast-enhanced brain MRI. 3D T 1 -weighted inversion-recovery prepped fast-spoiled-gradient-echo (IR-FSPGR) imaging was acquired at both 1.5T and 3T. In 60 brain MRI exams, the IR-FSPGR sequence was obtained under three conditions: precontrast, postcontrast images with 10% low-dose (0.01mmol/kg) and 100% full-dose (0.1 mmol/kg) of gadobenate dimeglumine. We trained a deep learning model using the first 10 cases (with mixed indications) to approximate full-dose images from the precontrast and low-dose images. Synthesized full-dose images were created using the trained model in two test sets: 20 patients with mixed indications and 30 patients with glioma. For both test sets, low-dose, true full-dose, and the synthesized full-dose postcontrast image sets were compared quantitatively using peak-signal-to-noise-ratios (PSNR) and structural-similarity-index (SSIM). For the test set comprised of 20 patients with mixed indications, two neuroradiologists scored blindly and independently for the three postcontrast image sets, evaluating image quality, motion-artifact suppression, and contrast enhancement compared with precontrast images. Results were assessed using paired t-tests and noninferiority tests. The proposed deep learning method yielded significant (n = 50, P 5 dB PSNR gains and >11.0% SSIM). Ratings on image quality (n = 20, P = 0.003) and contrast enhancement (n = 20, P deep learning method, gadolinium dose can be reduced 10-fold while preserving contrast information and avoiding significant image quality degradation. 3 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.

  4. An Interventional Magnetic Resonance Imaging Technique for the Molecular Characterization of Intraprostatic Dynamic Contrast Enhancement

    Directory of Open Access Journals (Sweden)

    Cynthia Ménard

    2005-01-01

    Full Text Available The biological characterization of an individual patient's tumor by noninvasive imaging will have an important role in cancer care and clinical research if the molecular processes that underlie the image data are known. Spatial heterogeneity in the dynamics of magnetic resonance imaging contrast enhancement (DCE-MRI is hypothesized to reflect variations in tumor angiogenesis. Here we demonstrate the feasibility of precisely colocalizing DCE-MRI data with the genomic and proteomic profiles of underlying biopsy tissue using a novel MRI-guided biopsy technique in patients with prostate cancer.

  5. Intralobar bronchopulmonary sequestration evaluated by contrast-enhanced three-dimensional MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kouchi, K.; Yoshida, H.; Matsunaga, T.; Ohtsuka, Y.; Kuroda, H.; Hishiki, T.; Satou, Y.; Terui, K.; Mitsunaga, T.; Ohnuma, N. [Department of Paediatric Surgery, School of Medicine, Chiba Univ. (Japan)

    2000-11-01

    Bronchopulmonary sequestration (PS) is characterized by non-functioning lung tissue fed from one or several aberrant systemic arteries. The condition is diagnosed by visualizing the feeding arteries using non-invasive CT, MRI, colour Doppler sonography or conventional angiography. We present a 5-year-old boy in whom intralobar sequestration was diagnosed using contrast-enhanced 3D MR angiography, which visualised fine blood vessels in the thoraco-abdominal region without arterial puncture. This technique is useful for diagnosing PS. (orig.)

  6. Intracranial Hypertension as an Acute Complication of Aseptic Meningoencephalitis with Leptomeningeal Contrast Enhancement on FLAIR MRI

    Directory of Open Access Journals (Sweden)

    Marc E. Wolf

    2016-01-01

    Full Text Available We report a case of a 19-year-old woman who developed intracranial hypertension as an unusual clinical complication of severe aseptic meningoencephalitis probably due to a diminished cerebrospinal fluid reabsorption capacity or leptomeningeal transudation as a consequence of blood-brain barrier dysfunction. These severe inflammatory changes were accompanied by prominent leptomeningeal contrast enhancement best visualized on fluid-attenuated inversion recovery magnetic resonance imaging. In such a prolonged course, a continuous lumbar drainage might be a temporary option to provide rapid symptom relief to the patient.

  7. Intrarenal arteriovenous shunts in kidney transplants demonstrated by contrast-enhanced ultrasound.

    Science.gov (United States)

    Mafeld, Sebastian; Stenberg, Ben; Elliott, Simon

    2015-01-01

    The kidney can undergo several hemodynamic changes in response to physiological stressful conditions. Arteriovenous (AV) shunting is an example where renal blood flow is redistributed away from the cortex toward the metabolically vulnerable medulla. Identification of this phenomenon is important as it may reflect underlying pathology. Despite evidence of renal AV shunting, its existence has been questioned. To our knowledge, this case series demonstrates for the first time the presence of renal AV shunting using contrast enhanced ultrasound. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. High sensitivity contrast enhanced optical coherence tomography for functional in vivo imaging

    Science.gov (United States)

    Liba, Orly; SoRelle, Elliott D.; Sen, Debasish; de la Zerda, Adam

    2017-02-01

    In this study, we developed and applied highly-scattering large gold nanorods (LGNRs) and custom spectral detection algorithms for high sensitivity contrast-enhanced optical coherence tomography (OCT). We were able to detect LGNRs at a concentration as low as 50 pM in blood. We used this approach for noninvasive 3D imaging of blood vessels deep in solid tumors in living mice. Additionally, we demonstrated multiplexed imaging of spectrally-distinct LGNRs that enabled observations of functional drainage in lymphatic networks. This method, which we call MOZART, provides a platform for molecular imaging and characterization of tissue noninvasively at cellular resolution.

  9. Application of contrast-enhanced ultrasound after liver transplantation: Current status and perspectives.

    Science.gov (United States)

    Ren, Jie; Wu, Tao; Zheng, Bo-Wen; Tan, Ying-Yi; Zheng, Rong-Qin; Chen, Gui-Hua

    2016-01-28

    Liver transplantation is an effective treatment for patients with end-stage liver disease. Accurate imaging evaluation of the transplanted patient is critical for ensuring that the limited donor liver is functioning appropriately. Ultrasound contrast agents (UCAs), in combination with contrast-specific imaging techniques, are increasingly accepted in clinical use for the assessment of the hepatic vasculature, bile ducts and liver parenchyma in pre-, intra- and post-transplant patients. We describe UCAs, their technical requirements, the recommended clinical indications, image interpretation and the limitations for contrast-enhanced ultrasound applications in liver transplantation.

  10. Atypical focal non-neoplastic brain changes in neurofibromatosis type 1: mass effect and contrast enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Raininko, R. [Dept. of Oncology, Radiology and Clinical Immunology, Section of Radiology, Uppsala University (Sweden); Thelin, L. [Dept. of Pediatrics, Gaevle County Hospital (Sweden); Eeg-Olofsson, O. [Dept. of Women' s and Children' s Health, Section of Pediatrics, Uppsala University (Sweden)

    2001-07-01

    Abstract Children and young adults with neurofibromatosis type 1 often have small high-signal foci on T2-weighted images of the brain. We describe follow-up of two patients in whom one of the foci had atypical features, commonly regarded as signs of a neoplasm. In the first, one lesion showed temporary contrast enhancement and decreasing mass effect. The second developed an expanding lesion that increased minimally in size over 4.5 year's follow-up. The borderline between neoplastic and non-neoplastic lesions seems to be indistinct. (orig.)

  11. Contrast Enhanced Ultrasound of the Kidneys: What Is It Capable of?

    Directory of Open Access Journals (Sweden)

    Demosthenes D. Cokkinos

    2013-01-01

    Full Text Available One of the many imaging uses of contrast enhanced ultrasound (CEUS is studying a wide variety of kidney pathology, due to its ability to detect microvascular blood flow in real time without affecting renal function. CEUS enables dynamic assessment and quantification of microvascularisation up to capillary perfusion. The objective of this paper is to briefly refresh basic knowledge of ultrasound (US contrast agents’ physical properties, to study technical details of CEUS scanning in the kidneys, and to review the commonest renal indications for CEUS, with imaging examples in comparison to baseline unenhanced US and computed tomography when performed. Safety matters and limitations of CEUS of the kidneys are also discussed.

  12. An evaluation of the clinical diagnostic value of contrast-enhanced ultrasound combined with contrast-enhanced computed tomography in space-occupying lesions of the kidney

    Directory of Open Access Journals (Sweden)

    Tian W

    2017-07-01

    Full Text Available Wen Tian,1 Jianbo Lu,2 Dan Jiao,3 Zhibin Cong2 1Department of Blood Transfusion, The Second Hospital of Jilin University, 2Department of Ultrasound, Affiliated Hospital of Changchun University of Traditional Chinese Medicine, 3Department of Ultrasound, China-Japan Union Hospital of Jilin University, Changchun, Jilin, People’s Republic of China Background: There are a variety of space-occupying lesions of the kidney, and the benign lesions may be difficult to differentiate from the malignant ones. Therefore, an accurate judgment of the benign and malignant nature of the space-occupying lesions of the kidney is of high importance for the treatment and prognosis of these patients.Objective: To evaluate the diagnostic value of contrast-enhanced ultrasound (CEUS combined with contrast-enhanced computed tomography (CECT in space-occupying lesions of the kidney.Data and methods: Three hundred and sixty-seven patients with space-occupying lesions of the kidney (378 lesions were examined by CEUS and CECT, respectively, then, a combined diagnosis was made after the combination of CEUS and CECT by a multidisciplinary team. The diagnoses from the three methods were compared. The pathological results were taken as the gold standard. The sensitivity, specificity, positive and negative predictive values and area under the receiver operating characteristic (ROC curve were calculated for the three methods. Thus, the diagnostic value of the three methods was assessed.Results: Of the 378 lesions examined, there were 301 malignant lesions and 77 benign lesions. The combined examination revealed 303 malignant lesions, with 9 benign lesions mistakenly diagnosed as malignant ones; thus, the misdiagnosis rate was 11.7%. By using the combined examination, 75 benign lesions were diagnosed, with the missed diagnosis of 7 malignant lesions, so the missed diagnosis rate was 2.3%. The sensitivity, specificity, positive and negative predictive values and area under the ROC

  13. Comparison of arterial input functions measured from ultra-fast dynamic contrast enhanced MRI and dynamic contrast enhanced computed tomography in prostate cancer patients

    Science.gov (United States)

    Wang, Shiyang; Lu, Zhengfeng; Fan, Xiaobing; Medved, Milica; Jiang, Xia; Sammet, Steffen; Yousuf, Ambereen; Pineda, Federico; Oto, Aytekin; Karczmar, Gregory S.

    2018-02-01

    The purpose of this study was to evaluate the accuracy of arterial input functions (AIFs) measured from dynamic contrast enhanced (DCE) MRI following a low dose of contrast media injection. The AIFs measured from DCE computed tomography (CT) were used as ‘gold standard’. A total of twenty patients received CT and MRI scans on the same day. Patients received 120 ml Iohexol in DCE-CT and a low dose of (0.015 mM kg‑1) of gadobenate dimeglumine in DCE-MRI. The AIFs were measured in the iliac artery and normalized to the CT and MRI contrast agent doses. To correct for different temporal resolution and sampling periods of CT and MRI, an empirical mathematical model (EMM) was used to fit the AIFs first. Then numerical AIFs (AIFCT and AIFMRI) were calculated based on fitting parameters. The AIFMRI was convolved with a ‘contrast agent injection’ function (AIFMRICON ) to correct for the difference between MRI and CT contrast agent injection times (~1.5 s versus 30 s). The results show that the EMMs accurately fitted AIFs measured from CT and MRI. There was no significant difference (p  >  0.05) between the maximum peak amplitude of AIFs from CT (22.1  ±  4.1 mM/dose) and MRI after convolution (22.3  ±  5.2 mM/dose). The shapes of the AIFCT and AIFMRICON were very similar. Our results demonstrated that AIFs can be accurately measured by MRI following low dose contrast agent injection.

  14. Ultrafast 3D spin-echo acquisition improves Gadolinium-enhanced MRI signal contrast enhancement

    Science.gov (United States)

    Han, S. H.; Cho, F. H.; Song, Y. K.; Paulsen, J.; Song, Y. Q.; Kim, Y. R.; Kim, J. K.; Cho, G.; Cho, H.

    2014-01-01

    Long scan times of 3D volumetric MR acquisitions usually necessitate ultrafast in vivo gradient-echo acquisitions, which are intrinsically susceptible to magnetic field inhomogeneities. This is especially problematic for contrast-enhanced (CE)-MRI applications, where non-negligible T2* effect of contrast agent deteriorates the positive signal contrast and limits the available range of MR acquisition parameters and injection doses. To overcome these shortcomings without degrading temporal resolution, ultrafast spin-echo acquisitions were implemented. Specifically, a multiplicative acceleration factor from multiple spin echoes (×32) and compressed sensing (CS) sampling (×8) allowed highly-accelerated 3D Multiple-Modulation-Multiple-Echo (MMME) acquisition. At the same time, the CE-MRI of kidney with Gd-DOTA showed significantly improved signal enhancement for CS-MMME acquisitions (×7) over that of corresponding FLASH acquisitions (×2). Increased positive contrast enhancement and highly accelerated acquisition of extended volume with reduced RF irradiations will be beneficial for oncological and nephrological applications, in which the accurate in vivo 3D quantification of contrast agent concentration is necessary with high temporal resolution. PMID:24863102

  15. Vascular Structure Identification in Intraoperative 3D Contrast-Enhanced Ultrasound Data

    Science.gov (United States)

    Ilunga-Mbuyamba, Elisee; Avina-Cervantes, Juan Gabriel; Lindner, Dirk; Cruz-Aceves, Ivan; Arlt, Felix; Chalopin, Claire

    2016-01-01

    In this paper, a method of vascular structure identification in intraoperative 3D Contrast-Enhanced Ultrasound (CEUS) data is presented. Ultrasound imaging is commonly used in brain tumor surgery to investigate in real time the current status of cerebral structures. The use of an ultrasound contrast agent enables to highlight tumor tissue, but also surrounding blood vessels. However, these structures can be used as landmarks to estimate and correct the brain shift. This work proposes an alternative method for extracting small vascular segments close to the tumor as landmark. The patient image dataset involved in brain tumor operations includes preoperative contrast T1MR (cT1MR) data and 3D intraoperative contrast enhanced ultrasound data acquired before (3D-iCEUSstart) and after (3D-iCEUSend) tumor resection. Based on rigid registration techniques, a preselected vascular segment in cT1MR is searched in 3D-iCEUSstart and 3D-iCEUSend data. The method was validated by using three similarity measures (Normalized Gradient Field, Normalized Mutual Information and Normalized Cross Correlation). Tests were performed on data obtained from ten patients overcoming a brain tumor operation and it succeeded in nine cases. Despite the small size of the vascular structures, the artifacts in the ultrasound images and the brain tissue deformations, blood vessels were successfully identified. PMID:27070610

  16. Technical Note: Quantitative dynamic contrast-enhanced MRI of a 3-dimensional artificial capillary network.

    Science.gov (United States)

    Gaass, Thomas; Schneider, Moritz Jörg; Dietrich, Olaf; Ingrisch, Michael; Dinkel, Julien

    2017-04-01

    Variability across devices, patients, and time still hinders widespread recognition of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) as quantitative biomarker. The purpose of this work was to introduce and characterize a dedicated microchannel phantom as a model for quantitative DCE-MRI measurements. A perfusable, MR-compatible microchannel network was constructed on the basis of sacrificial melt-spun sugar fibers embedded in a block of epoxy resin. Structural analysis was performed on the basis of light microscopy images before DCE-MRI experiments. During dynamic acquisition the capillary network was perfused with a standard contrast agent injection system. Flow-dependency, as well as inter- and intrascanner reproducibility of the computed DCE parameters were evaluated using a 3.0 T whole-body MRI. Semi-quantitative and quantitative flow-related parameters exhibited the expected proportionality to the set flow rate (mean Pearson correlation coefficient: 0.991, P quantitative parameters. All evaluated parameters were well in the range of known in vivo results for the applied flow rates. The constructed phantom enables reproducible, flow-dependent, contrast-enhanced MR measurements with the potential to facilitate standardization and comparability of DCE-MRI examinations. © 2017 American Association of Physicists in Medicine.

  17. Microarray Gene Expression Analysis of Murine Tumor Heterogeneity Defined by Dynamic Contrast-Enhanced MRI

    Directory of Open Access Journals (Sweden)

    Nick G. Costouros

    2002-07-01

    Full Text Available Current methods of studying angiogenesis are limited in their ability to serially evaluate in vivo function throughout a target tissue. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI and pharmacokinetic modeling provide a useful method for evaluating tissue vasculature based on contrast accumulation and washout. While it is often assumed that areas of high contrast enhancement and washout comprise areas of increased angiogenesis and tumor activity, the actual molecular pathways that are active in such areas are poorly understood. Using DCE-MRI in a murine subcutaneous tumor model, we were able to perform pharmacokinetic functional analysis of a tumor, coregistration of MRI images with histological cross-sections, immunohistochemistry, laser capture microdissection, and genetic profiling of tumor heterogeneity based on pharmacokinetic parameters. Using imaging as a template for biologic investigation, we have not found evidence of increased expression of proangiogenic modulators at the transcriptional level in either distinct pharmacokinetic region. Furthermore, these regions show no difference on histology and CD31 immunohistochemistry. However, the expression of ribosomal proteins was greatly increased in high enhancement and washout regions, implying increased protein translation and consequent increased cellular activity. Together, these findings point to the potential importance of posttranscriptional regulation in angiogenesis and the need for the development of angiogenesis-specific contrast agents to evaluate in vivo angiogenesis at a molecular level.

  18. Evaluation of Feline Renal Perfusion with Contrast-Enhanced Ultrasonography and Scintigraphy

    Science.gov (United States)

    Vanderperren, Katrien; Bosmans, Tim; Dobbeleir, André; Duchateau, Luc; Hesta, Myriam; Lybaert, Lien; Peremans, Kathelijne; Vandermeulen, Eva; Saunders, Jimmy

    2016-01-01

    Contrast-enhanced ultrasound (CEUS) is an emerging technique to evaluate tissue perfusion. Promising results have been obtained in the evaluation of renal perfusion in health and disease, both in human and veterinary medicine. Renal scintigraphy using 99mTc-Mercaptoacetyltriglycine (MAG3) is another non-invasive technique that can be used to evaluate renal perfusion. However, no data are available on the ability of CEUS or 99mTc- MAG3 scintigraphy to detect small changes in renal perfusion in cats. Therefore, both techniques were applied in a normal feline population to evaluate detection possibilities of perfusion changes by angiotensin II (AT II). Contrast-enhanced ultrasound using a bolus injection of commercially available contrast agent and renal scintigraphy using 99mTc-MAG3 were performed in 11 healthy cats after infusion of 0,9% NaCl (control) and AT II. Angiotensin II induced changes were noticed on several CEUS parameters. Mean peak enhancement, wash-in perfusion index and wash-out rate for the entire kidney decreased significantly after AT II infusion. Moreover, a tendency towards a lower wash-in area-under-the curve was present. Renal scintigraphy could not detect perfusion changes induced by AT II. This study shows that CEUS is able to detect changes in feline renal perfusion induced by AT II infusion. PMID:27736928

  19. A new combined technique for automatic contrast enhancement of digital images

    Directory of Open Access Journals (Sweden)

    Ismail A. Humied

    2012-03-01

    Full Text Available Some low contrast images have certain characteristics makes it difficult to use traditional methods to improve it. An example of these characteristics, that the amplitudes of images histogram components are very high at one location on the gray scale and very small in the rest of the gray scale. In the present paper, a new method is described. It can deal with such cases. The proposed method is a combination of Histogram Equalization (HE and Fast Gray-Level Grouping (FGLG. The basic procedure of this method is segments the original histogram of a low contrast image into two sub-histograms according to the location of the highest amplitude of the histogram components, and achieving contrast enhancement by equalizing the left segment of the histogram components using (HE technique and using (FGLG technique to equalize the right segment of this histogram components. The results have shown that the proposed method does not only produce better results than each individual contrast enhancement technique, but it is also fully automated. Moreover, it is applicable to a broad variety of images that satisfy the properties mentioned above and suffer from low contrast.

  20. Physiological assessment of contrast-enhancing frequency shaping and multiband compression in hearing aids.

    Science.gov (United States)

    Bruce, Ian C

    2004-08-01

    Spectral enhancement is now being used in many hearing aids in an attempt to compensate for broadened cochlear filtering. However, spectral enhancement may be counteracted by multiband-compression algorithms designed to compensate for the reduced dynamic range of the impaired cochlea. An alternative scheme for spectral enhancement, contrast-enhancing frequency shaping (CEFS), has been proposed, which results in an improved neural representation of the first and second formants of voiced speech segments in the impaired ear. In this paper, models of the normal and impaired ear are used to assess the compatibility of CEFS with multiband compression. Model auditory nerve responses were assessed under four conditions: (1) unmodified speech presented to a normal ear; (2) amplified, unshaped speech presented to an impaired ear; (3) CEFS speech presented to an impaired ear; and (4) CEFS+multiband-compression speech presented to an impaired ear. The results show that multiband compression does not reduce the benefits of CEFS, and in some cases multiband compression assists in preventing distortion of the neural representation of formants. These results indicate that the combination of contrast-enhancing frequency shaping and multiband compression should lead to improved perception of voiced speech segments in hearing aid users.

  1. The Optimization of Scan Timing for Contrast-Enhanced Magnetic Resonance Angiography

    Science.gov (United States)

    Tirman, Phillip J.; Chang, Yongmin; Ryeom, Hun-Kyu; Lee, Sang-Kwon; Kim, Yong-Sun; Kang, Duk-Sik

    2000-01-01

    Objective To determine the optimal scan timing for contrast-enhanced magnetic resonance angiography and to evaluate a new timing method based on the arteriovenous circulation time. Materials and Methods Eighty-nine contrast-enhanced magnetic resonance angiographic examinations were performed mainly in the extremities. A 1.5T scanner with a 3-D turbo-FLASH sequence was used, and during each study, two consecutive arterial phases and one venous phase were acquired. Scan delay time was calculated from the time-intensity curve by the traditional (n = 48) and/or the new (n = 41) method. This latter was based on arteriovenous circulation time rather than peak arterial enhancement time, as used in the traditional method. The numbers of first-phase images showing a properly enhanced arterial phase were compared between the two methods. Results Mean scan delay time was 5.4 sec longer with the new method than with the traditional. Properly enhanced first-phase images were found in 65% of cases (31/48) using the traditional timing method, and 95% (39/41) using the new method. When cases in which there was mismatch between the target vessel and the time-intensity curve acquisition site are excluded, erroneous acquisition occurred in seven cases with the traditional method, but in none with the new method. Conclusion The calculation of scan delay time on the basis of arteriovenous circulation time provides better timing for arterial phase acquisition than the traditional method. PMID:11752945

  2. Contrast enhanced pulmonary magnetic resonance angiography for pulmonary embolism: Building a successful program.

    Science.gov (United States)

    Nagle, Scott K; Schiebler, Mark L; Repplinger, Michael D; François, Christopher J; Vigen, Karl K; Yarlagadda, Rajkumar; Grist, Thomas M; Reeder, Scott B

    2016-03-01

    The performance of contrast enhanced pulmonary magnetic resonance angiography (MRA) for the diagnosis of pulmonary embolism (PE) is an effective non-ionizing alternative to contrast enhanced computed tomography and nuclear medicine ventilation/perfusion scanning. However, the technical success of these exams is very dependent on careful attention to the details of the MRA acquisition protocol and requires reader familiarity with MRI and its artifacts. Most practicing radiologists are very comfortable with the performance and interpretation of computed tomographic angiography (CTA) performed to detect pulmonary embolism but not all are as comfortable with the use of MRA in this setting. The purpose of this review is to provide the general radiologist with the tools necessary to build a successful pulmonary embolism MRA program. This review will cover in detail image acquisition, image interpretation, and some key elements of outreach that help to frame the role of MRA to consulting clinicians and hospital administrators. It is our aim that this resource will help build successful clinical pulmonary embolism MRA programs that are well received by patients and physicians, reduce the burden of medical imaging radiation, and maintain good patient outcomes. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Contrast-Enhanced Quantitative Intravascular Elastography: The Impact of Microvasculature on Model-Based Elastography.

    Science.gov (United States)

    Huntzicker, Steven; Shekhar, Himanshu; Doyley, Marvin M

    2016-05-01

    Model-based intravascular ultrasound elastography visualizes the stress distribution within vascular tissue-information that clinicians could use to predict the propensity of atherosclerotic plaque rupture. However, there are concerns that clusters of microvessels may reduce the accuracy of the estimated stress distribution. Consequently, we have developed a contrast-enhanced intravascular ultrasound system to investigate how plaque microvasculature affects the performance of model-based elastography. In simulations, diameters of 200, 400 and 800 μm were used, where the latter diameter represented a cluster of microvessels. In phantoms, we used a microvessel with a diameter of 750 μm. Peak stress errors of 3% and 38% were incurred in the fibrous cap when stress recovery was performed with and without a priori information about microvessel geometry. The results indicate that incorporating geometric information about plaque microvasculature obtained with contrast-enhanced ultrasound imaging improves the accuracy of estimates of the stress distribution within the fibrous cap precisely. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. Vascular Structure Identification in Intraoperative 3D Contrast-Enhanced Ultrasound Data

    Directory of Open Access Journals (Sweden)

    Elisee Ilunga-Mbuyamba

    2016-04-01

    Full Text Available In this paper, a method of vascular structure identification in intraoperative 3D Contrast-Enhanced Ultrasound (CEUS data is presented. Ultrasound imaging is commonly used in brain tumor surgery to investigate in real time the current status of cerebral structures. The use of an ultrasound contrast agent enables to highlight tumor tissue, but also surrounding blood vessels. However, these structures can be used as landmarks to estimate and correct the brain shift. This work proposes an alternative method for extracting small vascular segments close to the tumor as landmark. The patient image dataset involved in brain tumor operations includes preoperative contrast T1MR (cT1MR data and 3D intraoperative contrast enhanced ultrasound data acquired before (3D-iCEUS s t a r t and after (3D-iCEUS e n d tumor resection. Based on rigid registration techniques, a preselected vascular segment in cT1MR is searched in 3D-iCEUS s t a r t and 3D-iCEUS e n d data. The method was validated by using three similarity measures (Normalized Gradient Field, Normalized Mutual Information and Normalized Cross Correlation. Tests were performed on data obtained from ten patients overcoming a brain tumor operation and it succeeded in nine cases. Despite the small size of the vascular structures, the artifacts in the ultrasound images and the brain tissue deformations, blood vessels were successfully identified.

  5. Evaluating noise reduction techniques while considering anatomical noise in dual-energy contrast-enhanced mammography.

    Science.gov (United States)

    Allec, Nicholas; Abbaszadeh, Shiva; Scott, Chris C; Karim, Karim S; Lewin, John M

    2013-05-01

    The authors describe modifications to previously developed cascaded systems analysis to include the anatomical noise in evaluation of dual-energy noise reduction techniques. Previous models have ignored the anatomical noise in theoretical analysis of noise reduction techniques. The inclusion of anatomical noise leads to more accurate estimation of potential noise reduction improvements and optimization. The model is applied to dual-energy contrast-enhanced mammography. The effect of linear noise reduction filters on the anatomical noise is taken into account using cascaded systems analysis. The noise model is included in the ideal observer detectability for performance evaluation of the noise reduction techniques. Dual-energy image noise with and without including the effect of anatomical noise in noise reduction technique analysis is reported. The theoretical model is compared with clinical images from a previous dual-energy contrast enhanced mammography clinical study and good agreement is observed. The results suggest that the inclusion of anatomical noise in the evaluation and comparison of noise reduction techniques is highly warranted for more accurate analysis. This work establishes a useful extension to dual-energy cascaded systems analysis for maximizing image quality using noise reduction techniques. The extension includes the effect of linear image filtering, such as that used for noise reduction, on anatomical noise. The results suggest that the inclusion of anatomical noise in the evaluation of noise reduction techniques can lead to more accurate optimization, noise, and performance estimations.

  6. Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography.

    Science.gov (United States)

    Diekmann, Felix; Bick, Ulrich

    2007-12-01

    Digital mammography is more and more replacing conventional mammography. Initial concerns about an inferior image quality of digital mammography have been largely overcome and recent studies even show digital mammography to be superior in women with dense breasts, while at the same time reducing radiation exposure. Nevertheless, an important limitation of digital mammography remains: namely, the fact that summation may obscure lesions in dense breast tissue. However, digital mammography offers the option of so-called advanced applications, and two of these, contrast-enhanced mammography and tomosynthesis, are promising candidates for improving the detection of breast lesions otherwise obscured by the summation of dense tissue. Two techniques of contrast-enhanced mammography are available: temporal subtraction of images acquired before and after contrast administration and the so-called dual-energy technique, which means that pairs of low/high-energy images acquired after contrast administration are subtracted. Tomosynthesis on the other hand provides three-dimensional information on the breast. The images are acquired with different angulations of the X-ray tube while the object or detector is static. Various reconstruction algorithms can then be applied to the set of typically nine to 28 source images to reconstruct 1-mm slices with a reduced risk of obscuring pathology. Combinations of both advanced applications have only been investigated in individual experimental studies; more advanced software algorithms and CAD systems are still in their infancy and have only undergone preliminary clinical evaluation.

  7. Ultrasound elastography and contrast-enhanced ultrasound in infants, children and adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Martin, E-mail: martin.stenzel@med.uni-jena.de; Mentzel, Hans-Joachim

    2014-09-15

    Objective: To describe prerequisites, use, and safety of ultrasound elastography and contrast-enhanced ultrasound in infants, children, and adolescents. Method: This review deals with two latest developments in ultrasonography in children. The principle of strain elastography, transient elastography, and acoustic radiation force imaging is discussed, including limitations, and advantages of the different techniques in diagnosing focal and diffuse organ disease. The intravesical (contrast-enhanced voiding ultrasonography) and intravascular use of contrast-media to outline blood, and urinary flow is described, with special emphasis on indications, off-label use, and diagnostic gain. Examples of indications for performing the advanced ultrasound techniques are presented. Summary and conclusion: Latest developments in ultrasound machine engineering, and the availability of contrast-media that interact with ultrasound waves allow for assessment of tissue stiffness/elasticity properties, blood, and urinary flow. Thereby ultrasound is capable not only to depict morphology, but gives the additional information on organ, and focal lesion perfusion, and urinary flow dynamics. The information gap to other cross-sectional techniques such as magnetic resonance imaging, that make potential harmful sedation, and anaesthesia in the youngest children necessary, thereby gets closer.

  8. Contrast Enhanced Pulmonary Magnetic Resonance Angiography for Pulmonary Embolism: Building a Successful Program

    Science.gov (United States)

    Nagle, Scott K; Schiebler, Mark L; Repplinger, Michael D; François, Christopher J; Vigen, Karl K; Yarlagadda, Rajkumar; Grist, Thomas M; Reeder, Scott B

    2016-01-01

    The performance of contrast enhanced pulmonary magnetic resonance angiography (MRA) for the diagnosis of pulmonary embolism (PE) is an effective non-ionizing alternative to contrast enhanced computed tomography and nuclear medicine ventilation/perfusion scanning. However, the technical success of these exams is very dependent on careful attention to the details of the MRA acquisition protocol and requires reader familiarity with MRI and its artifacts. Most practicing radiologists are very comfortable with the performance and interpretation of computed tomographic angiography (CTA) performed to detect pulmonary embolism but not all are as comfortable with the use of MRA in this setting. The purpose of this review is to provide the general radiologist with the tools necessary to build a successful pulmonary embolism MRA program. This review will cover in detail image acquisition, image interpretation, and some key elements of outreach that help to frame the role of MRA to consulting clinicians and hospital administrators. It is our aim that this resource will help build successful clinical pulmonary embolism MRA programs that are well received by patients and physicians, reduce the burden of medical imaging radiation, and maintain good patient outcomes. PMID:26860667

  9. Contrast enhancement pattern on multidetector CT predicts malignancy in pancreatic endocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Cappelli, Carla [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Azienda Ospedaliero-Universitaria Pisana-Radiodiagnostica I, Pisa (Italy); Boggi, Ugo [University of Pisa, General and Transplant Surgery, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Mazzeo, Salvatore; Cervelli, Rosa; Contillo, Benedetta Pontillo; Bartolozzi, Carlo [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Campani, Daniela; Funel, Niccola [University of Pisa, Pathology, Department of Surgical, Medical, Molecular and Critical Area Pathology, Pisa (Italy)

    2014-12-02

    Preoperative suspicion of malignancy in pancreatic neuroendocrine tumours (pNETs) is mostly based on tumour size. We retrospectively reviewed the contrast enhancement pattern (CEP) of a series of pNETs on multiphasic multidetector computed tomography (MDCT), to identify further imaging features predictive of lesion aggressiveness. Sixty pNETs, diagnosed in 52 patients, were classified based on CEP as: type A showing early contrast enhancement and rapid wash-out; type B presenting even (B1) or only (B2) late enhancement. All tumours were resected allowing pathologic correlations. Nineteen pNETs showed type A CEP (5-20 mm), 29 type B1 CEP (5-80 mm) and 12 type B2 (15-100 mm). All tumours were classified as well differentiated tumours, 19 were benign (WDt-b), 15 with uncertain behaviour (WDt-u) and 26 carcinomas (WDC). None of A lesions were malignant (12 WDt-b; 7 WDt-u), all B2 lesions were WDC, 7 B1 lesions were WDt-b, 8 WDt-u and 14 WDC; 4/34 (12 %) lesions ≤2cm were WDC. CEP showed correlation with all histological prognostic indicators. Correlating with the lesion grading and other histological prognostic predictors, CEP may preoperatively suggest the behaviour of pNETs, assisting decisions about treatment. Moreover CEP allows recognition of malignant small tumours, incorrectly classified on the basis of their dimension. (orig.)

  10. Reverse contrast enhancement in digital radiography in detection of vertical root fracture (in vitro

    Directory of Open Access Journals (Sweden)

    Sandra Mehralizadeh

    2015-07-01

    Full Text Available Background and Aims: Diagnosis of vertical root fractures often poses a clinical dilemma. Diagnosis of VRF in intraoral radiographs, except in cases where the beam is perpendicular to the direction of fracture is difficult. Misdiagnosis often leads to wrong decisions about the design of teeth future treatment plan. The aim of this study was to determine the diagnostic accuracy of reverse contrast enhancement options in digital radiography, and to compare it with the original images to find a suitable method to detect vertical root fracture.   Materials and Methods: In this experimental study, digital radiography with phosphor plate detector was taken from 40 extracted single root teeth. From each intact and fractured tooth, the original and reverse contrast images captured and stored. Two expert observers viewed the images twice with an interval of two weeks. Diagnostic criteria (Accuracy, PPV, NPV, Specificity and Sensitivity in form of absolute and complete for each observer and each images was calculated. Inter and intra observer reliability was obtained using Mc-Nemar test.   Results: No significant differences in inter-observer reliability between the initial appearance and reverse contrast was observed (P>0.05, but in view of the intra-observer reliability in two cases, the difference was significant (P0.05, whereas significant difference between the two images was found in NPV index (P<0.05.   Conclusion: The use of reverse contrast enhancement option for detection of vertical root fracture did not show significant difference from initial view.

  11. Contrast-enhanced ultrasonographic findings in three dogs with pancreatic insulinoma.

    Science.gov (United States)

    Nakamura, Kensuke; Lim, Sue-Yee; Ochiai, Kenji; Yamasaki, Masahiro; Ohta, Hiroshi; Morishita, Keitaro; Takagi, Satoshi; Takiguchi, Mitsuyoshi

    2015-01-01

    Abdominal ultrasonography is one of the most common diagnostic imaging modalities used for dogs with suspected insulinoma; however, pancreatic masses are clearly identified in fewer than half of affected dogs and benign pancreatic nodules can be difficult to differentiate from malignant ones. The purpose of this prospective study was to describe contrast-enhanced ultrasonography (CEUS) characteristics of confirmed pancreatic insulinoma in a group of dogs. Inclusion criteria were as follows: (1) repeated hypoglycemia (blood glucose levels ultrasonography; and (4) histological confirmation of pancreatic islet cell carcinoma. Immediately following conventional ultrasonography of the entire abdomen, CEUS of the pancreatic nodule and adjacent parenchyma was performed using contrast-specific technology pulse inversion imaging and perflubutane microbubble contrast agent. Three dogs met inclusion criteria. Pancreatic nodules in all the three dogs became more clearly demarcated after injection of the contrast agent. Each nodule showed different enhancement patterns: markedly hyperechoic for 5 s, slightly hyperechoic for 1 s, and clearly hypoechoic for over 30 s. These results were not in complete agreement with previously reported CEUS findings in human patients with insulinoma. All nodules were surgically resected and histopathologically confirmed as malignant insulinomas. Findings from the current study indicated that contrast-enhanced ultrasound may help to increase conspicuity of pancreatic insulinomas in dogs and that enhancement characteristics may be more variable in dogs than in humans. © 2014 American College of Veterinary Radiology.

  12. Prognostic significance of contrast-enhanced CT attenuation value in extrahepatic cholangiocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Asayama, Yoshiki [Kyushu University, Department of Advanced Imaging and Interventional Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Nishie, Akihiro; Ishigami, Kousei; Ushijima, Yasuhiro; Takayama, Yukihisa; Okamoto, Daisuke; Fujita, Nobuhiro; Honda, Hiroshi [Kyushu University, Departments of Clinical Radiology, Fukuoka (Japan); Ohtsuka, Takao [Kyushu University, Departments of Surgery and Oncology, Fukuoka (Japan); Yoshizumi, Tomoharu [Kyushu University, Departments of Surgery and Sciences, Fukuoka (Japan); Aishima, Shinichi [Saga University, Pathology and Microbiology, Faculty of Medicine, Saga (Japan); Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan); Oda, Yoshinao [Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2017-06-15

    To determine whether washout characteristics of dynamic contrast-enhanced computed tomography (CT) could predict survival in patients with extrahepatic cholangiocarcinoma (EHC). This study collected 46 resected cases. All cases were examined by dynamic contrast study on multidetector-row CT. Region-of-interest measurements were obtained at the non-enhanced, portal venous phase and delayed phase in the tumour and were used to calculate the washout ratio as follows: [(attenuation value at portal venous phase CT - attenuation value at delayed enhanced CT)/(attenuation value at portal venous phase CT - attenuation value at unenhanced CT)] x 100. On the basis of the median washout ratio, we classified the cases into two groups, a high-washout group and low-washout group. Associations between overall survival and various factors including washout rates were analysed. The median washout ratio was 29.4 %. Univariate analysis revealed that a lower washout ratio, venous invasion, lymphatic permeation and lymph node metastasis were associated with shorter survival. Multivariate analysis identified the lower washout ratio as an independent prognostic factor (hazard ratio, 3.768; p value, 0.027). The washout ratio obtained from the contrast-enhanced CT may be a useful imaging biomarker for the prediction of survival of patients with EHC. (orig.)

  13. Targeted Multifunctional Nanoparticles cure and image Brain Tumors: Selective MRI Contrast Enhancement and Photodynamic Therapy

    Science.gov (United States)

    Kopelman, Raoul

    2008-03-01

    Aimed at targeted therapy and imaging of brain tumors, our approach uses targeted, multi-functional nano-particles (NP). A typical nano-particle contains a biologically inert, non-toxic matrix, biodegradable and bio-eliminable over a long time period. It also contains active components, such as fluorescent chemical indicators, photo-sensitizers, MRI contrast enhancement agents and optical imaging dyes. In addition, its surface contains molecular targeting units, e.g. peptides or antibodies, as well as a cloaking agent, to prevent uptake by the immune system, i.e. enabling control of the plasma residence time. These dynamic nano-platforms (DNP) contain contrast enhancement agents for the imaging (MRI, optical, photo-acoustic) of targeted locations, i.e. tumors. Added to this are targeted therapy agents, such as photosensitizers for photodynamic therapy (PDT). A simple protocol, for rats implanted with human brain cancer, consists of tail injection with DNPs, followed by 5 min red light illumination of the tumor region. It resulted in excellent cure statistics for 9L glioblastoma.

  14. Reversible and Asymptomatic Gyral and Subarachnoid Contrast Enhancement after Carotid Stenting

    Science.gov (United States)

    Vangosa, Alessandra Briatico; Tortora, Domenico; Modestino, Francesco; Cotroneo, Antonio R

    2015-01-01

    The presence of sulcal hyperdensity in patients after endovascular procedures is not necessarily attributable to hemorrhage. It may frequently indicate the absolute or concomitant extravasation of contrast material into the subarachnoid spaces. This case report describes the clinical case of an 84-year-old patient with 90% stenosis of the right internal carotid who presented with a diffuse gyral and sulcal hyperdensity in the right temporal-occipital and frontal lobes at routine post-carotid stenting (CAS) brain CT scan. The patient was asymptomatic and CT findings were interpreted as contrast enhancement hyperattenuation and no therapeutic decisions were made. A 24-hour follow-up brain CT demonstrated the complete resolution of the hyperdensity, confirming the diagnosis. In this patient we considered the concomitant presence of gyral and sulcal hyperdensity as the consequence of reversible damage to the blood-brain barrier (BBB) determining a transitory extravasation of contrast material. Asymptomatic gyral and subarachnoid contrast enhancement following CAS is generally indicative of benign and transitory damage to the BBB and is not to be misinterpreted as hemorrhage. PMID:25923674

  15. Non-Infectious Peri-Electrode Edema and Contrast Enhancement Following Deep Brain Stimulation Surgery.

    Science.gov (United States)

    Arocho-Quinones, Elsa V; Pahapill, Peter A

    2016-12-01

    Dramatic radiographic abnormalities seen after electrode placement (DRAAEP) in deep brain stimulation (DBS) surgery is rare and it has not been associated with infection or hemorrhage. It has consisted of peri-electrode low-attenuation signals on CT scans and extensive T2-hyperintense signals without associated contrast enhancement (CE) on MRI scans. Report on the management of a patient with Parkinson's disease (PD) presenting with a seizure and findings of DRAAEP with positive CE 12 days after the placement of a subthalamic nucleus (STN) DBS electrode. Head CT and contrasted brain MRI scans were completed on presentation. Standard laboratory work up was obtained to evaluate for infection. Operative exploration deep to the burr-hole site surrounding the electrode was performed and cultures were obtained. Serial contrasted MRI scans were completed to determine the abnormal signal duration. A MRI revealed extensive T2-hyperintensity and positive CE concentrated around the burr-hole site surrounding the electrode. Intraoperative exploration revealed no evidence of infection and electrode revision was avoided. There was near resolution of the abnormal T2 signal and CE at six weeks from detection. The patient remained without signs of intracranial infection and responded well to DBS. To our knowledge, this is the first reported case of DRAAEP with positive gadolinium enhancement. Despite the extensive contrast enhancement, these DRAAEP appear to remain benign transient events that, in the absence of clinical signs of infection or neurologic decline, may warrant no further aggressive intervention such as hardware removal. © 2016 International Neuromodulation Society.

  16. Modifications in Dynamic Contrast-Enhanced Magnetic Resonance Imaging Parameters After α-Particle-Emitting {sup 227}Th-trastuzumab Therapy of HER2-Expressing Ovarian Cancer Xenografts

    Energy Technology Data Exchange (ETDEWEB)

    Heyerdahl, Helen, E-mail: Helen.Heyerdahl@rr-research.no [Department of Radiation Biology, Institute for Cancer Research, Oslo University Hospital - The Norwegian Radium Hospital, Oslo (Norway); Røe, Kathrine [Department of Oncology, Division of Medicine, Akershus University Hospital, Lørenskog (Norway); Brevik, Ellen Mengshoel [Department of Research and Development, Algeta ASA, Oslo (Norway); Dahle, Jostein [Nordic Nanovector AS, Oslo (Norway)

    2013-09-01

    Purpose: The purpose of this study was to investigate the effect of α-particle-emitting {sup 227}Th-trastuzumab radioimmunotherapy on tumor vasculature to increase the knowledge about the mechanisms of action of {sup 227}Th-trastuzumab. Methods and Materials: Human HER2-expressing SKOV-3 ovarian cancer xenografts were grown bilaterally in athymic nude mice. Mice with tumor volumes 253 ± 36 mm{sup 3} (mean ± SEM) were treated with a single injection of either {sup 227}Th-trastuzumab at a dose of 1000 kBq/kg body weight (treated group, n=14 tumors) or 0.9% NaCl (control group, n=10 tumors). Dynamic T1-weighted contrast-enhanced magnetic resonance imaging (DCEMRI) was used to study the effect of {sup 227}Th-trastuzumab on tumor vasculature. DCEMRI was performed before treatment and 1, 2, and 3 weeks after therapy. Tumor contrast-enhancement curves were extracted voxel by voxel and fitted to the Brix pharmacokinetic model. Pharmacokinetic parameters for the tumors that underwent radioimmunotherapy were compared with the corresponding parameters of control tumors. Results: Significant increases of k{sub ep}, the rate constant of diffusion from the extravascular extracellular space to the plasma (P<.05), and k{sub el,} the rate of clearance of contrast agent from the plasma (P<.01), were seen in the radioimmunotherapy group 2 and 3 weeks after injection, compared with the control group. The product of k{sub ep} and the amplitude parameter A, associated with increased vessel permeability and perfusion, was also significantly increased in the radioimmunotherapy group 2 and 3 weeks after injection (P<.01). Conclusions: Pharmacokinetic modeling of MRI contrast-enhancement curves evidenced significant alterations in parameters associated with increased tumor vessel permeability and tumor perfusion after {sup 227}Th-trastuzumab treatment of HER2-expressing ovarian cancer xenografts.

  17. Non-contrast-enhanced 4D MR angiography with STAR spin labeling and variable flip angle sampling: a feasibility study for the assessment of Dural Arteriovenous Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Jinhee; Kim, Bom-yi; Choi, Hyun Seok; Jung, So-Lyung; Ahn, Kook-Jin; Kim, Bum-soo [The Catholic University of Korea, Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, Seoul (Korea, Republic of); Schmitt, Peter [Siemens AG, Healthcare Sector, Erlangen (Germany); Kim, Inseong; Paek, Munyoung [Siemens AG, Healthcare, Seoul (Korea, Republic of)

    2014-04-15

    This study aimed to evaluate the feasibility of non-contrast-enhanced 4D magnetic resonance angiography (NCE 4D MRA) with signal targeting with alternative radiofrequency (STAR) spin labeling and variable flip angle (VFA) sampling in the assessment of dural arteriovenous fistula (DAVF) in the transverse sinus. Nine patients underwent NCE 4D MRA for the evaluation of DAVF in the transverse sinus at 3 T. One patient was examined twice, once before and once after the interventional treatment. All patients also underwent digital subtraction angiography (DSA) and/or contrast-enhanced magnetic resonance angiography (CEMRA). For the acquisition of NCE 4D MRA, a STAR spin tagging method was used, and a VFA sampling was applied in the data readout module instead of a constant flip angle. Two readers evaluated the NCE 4D MRA data for the diagnosis of DAVF and its type with consensus. The results were compared with those from DSA and/or CEMRA. All patients underwent NCE 4D MRA without any difficulty. Among seven patients with patent DAVFs, all cases showed an early visualization of the transverse sinus on NCE 4D MRA. Except for one case, the type of DAVF of NCE 4D MRA was agreed with that of reference standard study. Cortical venous reflux (CVR) was demonstrated in two cases out of three patients with CVR. NCE 4D MRA with STAR tagging and VFA sampling is technically and clinically feasible and represents a promising technique for assessment of DAVF in the transverse sinus. Further technical developments should aim at improvements of spatial and temporal coverage. (orig.)

  18. Intravenous contrast-enhanced CT of the postoperative lumbar spine: improved identification of recurrent disk herniation, scar, arachnoiditis, and diskitis

    Energy Technology Data Exchange (ETDEWEB)

    Teplick, J.G.; Haskin, M.E.

    1984-10-01

    Unsuccessful relief of symptoms after back surgery is usually attributable to hypertrophic extradural scar or recurrent herniated disk. Their clinical and myelographic differentiation is difficult, yet important because reoperation is not always beneficial for scar removal. This article examines the usefulness of intravenous contrast-enhanced computed tomography for this problem. Forty-five postsurgical patients were studied; eight had subsequent surgery. In the four with hypertrophic scars, intravenous contrast enhancement of the scar allowed its recognition in each case; in the four with hypertrophic scars, intravenous contrast enhancement of the scar allowed its recognition in each case; in the four with recurrent disk herniation, nonenhancement of the extruded disk allowed its recognition in three. In the other 37 patients who were not reoperated, 33 were believed to have scar on the basis of contrast enhancement. The method seems promising for more accurate evaluation of failed back surgery, including the recognition of diskitis.

  19. Evaluation of the microcirculatory disturbance of biliary ischemia after liver transplantation with contrast-enhanced ultrasound: preliminary experience

    National Research Council Canada - National Science Library

    Ren, Jie; Lu, Ming-De; Zheng, Rong-Qin; Lu, Min-Qiang; Liao, Mei; Mao, Yong-Jiang; Zheng, Zhi-Juan; Lu, Yan

    2009-01-01

    The aim of this study was to determine the efficacy of contrast-enhanced ultrasound for depicting the perfusion of hilar bile ducts in ischemic-type biliary lesions after orthotopic liver transplantation...

  20. Evaluation of dynamic contrast-enhanced T1-weighted perfusion MRI in the differentiation of tumor recurrence from radiation necrosis

    DEFF Research Database (Denmark)

    Larsen, Anne Vibeke Andrée; Simonsen, Helle J; Law, Ian

    2013-01-01

    to measure cerebral blood volume (CBV), blood-brain barrier (BBB) permeability and cerebral blood flow (CBF). Subjects also underwent FDG-PET and lesions were classified as either metabolically active or inactive. Follow-up clinical MRI and lesion histology in case of additional tissue resection was used...

  1. Cortical necrosis secondary to trauma in a child: contrast-enhanced ultrasound comparable to magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yusuf, Gibran T.; Sellars, Maria E.; Huang, Dean Y.; Deganello, Annamaria; Sidhu, Paul S. [King' s College Hospital, King' s College London, Department of Radiology, London (United Kingdom)

    2014-04-15

    Cortical necrosis is an uncommon cause of renal impairment and is rarely a consequence of blunt abdominal trauma. We present a case of unilateral traumatic acute cortical necrosis in a child demonstrated on contrast-enhanced US with confirmation on MRI. Contrast-enhanced US provides a rapid, accurate evaluation of renal parenchyma abnormalities in blunt abdominal trauma in children without exposure to ionising radiation or the risk of sedation. (orig.)

  2. A comparison of non-contrast and contrast-enhanced MRI in the initial stage of Legg-Calve-Perthes disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Harry K.W. [Texas Scottish Rite Hospital for Children, Center of Excellence in Hip Disorders, Dallas, TX (United States); University of Texas Southwestern, Department of Orthopedic Surgery, Dallas, TX (United States); Kaste, Sue [St. Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States); St. Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States); University of Tennessee School of Health Sciences, Department of Radiology, Memphis, TN (United States); Dempsey, Molly; Wilkes, David [Texas Scottish Rite Hospital for Children, Department of Radiology, Dallas, TX (United States)

    2013-09-15

    A prognostic indicator of outcome for Legg-Calve-Perthes disease (LCP) is needed to guide treatment decisions during the initial stage of the disease (stage 1), before deformity occurs. Radiographic prognosticators are applicable only after fragmentation (stage II). We investigated pre- and postcontrast MRI in depicting stage I femoral head involvement. Thirty children with stage I LCP underwent non-contrast coronal T1 fast spin-echo (FSE) and corresponding postcontrast fat-suppressed T1-weighted fast spin-echo (FSE) sequences to quantify the extent of femoral head involvement. Three pediatric radiologists and one pediatric orthopedic surgeon independently measured central head involvement. Interobserver reliability of percent head involvement using non-contrasted MR images had intraclass correlation coefficient (ICC) of 0.72. Postcontrast MRI improved interobserver reliability (ICC 0.82). Qualitatively, the area of involvement was more clearly visible on contrast-enhanced MRI. A comparison of results obtained by each observer using the two MRI techniques showed no correlation. ICC ranged from -0.08 to 0.03 for each observer. Generally, greater head involvement was depicted by contrast compared with non-contrast MRI (Pearson r = -0.37, P = 0.04). Pre- and postcontrast MRI assess two different components of stage I LCP. However, contrast-enhanced MRI more clearly depicts the area of involvement. (orig.)

  3. Low enhancement on multiphase contrast-enhanced CT images: an independent predictor of the presence of high tumor grade of clear cell renal cell carcinoma.

    Science.gov (United States)

    Zhu, Ye-Hua; Wang, Xun; Zhang, Jin; Chen, Yong-Hui; Kong, Wen; Huang, Yi-Ran

    2014-09-01

    The purpose of this study was to assess the relation between tumor enhancement on multiphase contrast-enhanced CT images and Fuhrman grade of clear cell renal cell carcinoma. A single-institution retrospective review was conducted on the records of 255 patients who underwent radical or partial nephrectomy and received a histologic diagnosis of clear cell renal cell carcinoma. Two radiologists recorded the radiographic features of each patient, including the attenuation value of the lesion, lesion size, calcification within the lesion, cystic versus solid appearance, and margin regularity. Parameters representing the extent of tumor enhancement were defined and calculated. The association between tumor enhancement and Fuhrman grade was analyzed, and multivariate analysis was performed to find independent predictors of high tumor grade. Significant differences existed in tumor enhancement among different Fuhrman grades (p enhancement (p enhancement parameter had a sensitivity of 0.84 and specificity of 0.93 in prediction of high tumor grade. In the multivariate analysis, more advanced age, irregular margin, and low tumor enhancement were the three independent predictors of high tumor grade. Tumor enhancement of clear cell renal cell carcinoma on multiphase contrast-enhanced CT images is associated with Fuhrman grade. Low tumor enhancement in the corticomedullary phase is an independent predictor of high tumor grade. This system may be helpful in clinical decision making about the care of patients treated by nonsurgical approaches.

  4. Validation of contrast-enhanced magnetic resonance imaging to monitor regenerative efficacy after cell therapy in a porcine model of convalescent myocardial infarction.

    Science.gov (United States)

    Malliaras, Konstantinos; Smith, Rachel R; Kanazawa, Hideaki; Yee, Kristine; Seinfeld, Jeffrey; Tseliou, Eleni; Dawkins, James F; Kreke, Michelle; Cheng, Ke; Luthringer, Daniel; Ho, Chak-Sum; Blusztajn, Agnieszka; Valle, Ileana; Chowdhury, Supurna; Makkar, Raj R; Dharmakumar, Rohan; Li, Debiao; Marbán, Linda; Marbán, Eduardo

    2013-12-24

    Magnetic resonance imaging (MRI) in the CArdiosphere-Derived aUtologous stem CElls to reverse ventricUlar dySfunction (CADUCEUS) trial revealed that cardiosphere-derived cells (CDCs) decrease scar size and increase viable myocardium after myocardial infarction (MI), but MRI has not been validated as an index of regeneration after cell therapy. We tested the validity of contrast-enhanced MRI in quantifying scarred and viable myocardium after cell therapy in a porcine model of convalescent MI. Yucatan minipigs underwent induction of MI and 2-3 weeks later were randomized to receive intracoronary infusion of 12.5×10(6) mismatched allogeneic CDCs or vehicle. Allogeneic CDCs induced mild local mononuclear infiltration but no systemic immunogenicity. MRI revealed that allogeneic CDCs attenuated remodeling, improved global and regional function, decreased scar size, and increased viable myocardium compared with placebo 2 months post-treatment. Extensive histological analysis validated quantitatively the MRI measurements of scar size, scar mass, and viable mass. CDCs neither altered gadolinium contrast myocardial kinetics nor induced changes in vascular density or architecture in viable and scarred myocardium. Histology demonstrated that CDCs lead to cardiomyocyte hyperplasia in the border zone, consistent with the observed stimulation of endogenous regenerative mechanisms (cardiomyocyte cycling, upregulation of endogenous progenitors, angiogenesis). Contrast-enhanced MRI accurately measures scarred and viable myocardium after cell therapy in a porcine model of convalescent MI. MRI represents a useful tool for assessing dynamic changes in the infarct and monitoring regenerative efficacy.

  5. Validation of Contrast-Enhanced MRI to Monitor Regenerative Efficacy after Cell Therapy in a Porcine Model of Convalescent Myocardial Infarction

    Science.gov (United States)

    Malliaras, Konstantinos; Smith, Rachel R.; Kanazawa, Hideaki; Yee, Kristine; Seinfeld, Jeffrey; Tseliou, Eleni; Dawkins, James F.; Kreke, Michelle; Cheng, Ke; Luthringer, Daniel; Ho, Chak-Sum; Blusztajn, Agnieszka; Valle, Ileana; Chowdhury, Supurna; Makkar, Raj R.; Dharmakumar, Rohan; Li, Debiao; Marbán, Linda; Marbán, Eduardo

    2014-01-01

    Background Magnetic Resonance Imaging (MRI) in the CADUCEUS trial revealed that cardiosphere-derived cells (CDCs) decrease scar size and increase viable myocardium post-myocardial infarction (MI), but MRI has not been validated as an index of regeneration after cell therapy. We tested the validity of contrast-enhanced MRI in quantifying scarred and viable myocardium after cell therapy in a porcine model of convalescent MI. Methods and Results Yucatan minipigs underwent induction of MI and 2-3 weeks later were randomized to receive intracoronary infusion of 12.5×106 mismatched allogeneic CDCs or vehicle. Allogeneic CDCs induced mild local mononuclear infiltration but no systemic immunogenicity. MRI revealed that allogeneic CDCs attenuated remodeling, improved global and regional function, decreased scar size and increased viable myocardium compared to placebo 2 months post-treatment. Extensive histological analysis validated quantitatively the MRI measurements of scar size, scar mass and viable mass. CDCs neither altered gadolinium contrast myocardial kinetics, nor induced changes in vascular density or architecture in viable and scarred myocardium. Histology demonstrated that CDCs lead to cardiomyocyte hyperplasia in the border zone, consistent with the observed stimulation of endogenous regenerative mechanisms (cardiomyocyte cycling, upregulation of endogenous progenitors, angiogenesis). Conclusions Contrast-enhanced MRI accurately measures scarred and viable myocardium after cell therapy in a porcine model of convalescent MI. MRI represents a useful tool for assessing dynamic changes in the infarct and monitoring regenerative efficacy. PMID:24061088

  6. Dynamic contrast-enhanced MR imaging of VX2 carcinomas after X-irradiation in rabbits: comparison of gadopentetate dimeglumine and a macromolecular contrast agent.

    Science.gov (United States)

    Kim, Young Hoon; Choi, Byung Ihn; Cho, Woo Ho; Lim, Sungjig; Moon, Woo Kyoung; Han, Joon Koo; Weinmann, Hanns-Joachim; Chang, Kee-Hyun

    2003-09-01

    To compare enhancement patterns of gadomer-17 with those of gadopentetate dimeglumine in VX2 carcinomas after irradiation on rabbits. Twelve rabbits with VX2 carcinoma in the thigh underwent dynamic contrast-enhanced magnetic resonance (MR) imaging with gadopentetate dimeglumine and gadomer-17 at 24-hour intervals before (n = 12), 3 days (group 1, n = 12), 1 month (group 2, n = 8) and 2 months (group 3, n = 4) after 30 Gy irradiation. After taking postirradiation MR images, 4 rabbits were killed for histopathologic examination at each time interval. The enhancement characteristics in MR imaging and morphology of tumor vessels in histopathologic specimen were assessed. After gadopentetate dimeglumine injection, the enhancement characteristics were not different among tumors before and after irradiation (P > 0.05). For gadomer-17, the enhancement ratios decreased after irradiation. The shape of the curves for tumor enhancement before irradiation was significantly different from curves of group 1(P < 0.05). The specimens from group 3 showed sclerosis and wall thickening in arterioles. Dynamic contrast-enhanced MR imaging with a gadomer-17 reveals increased capillary permeability at an early phase after irradiation and chronic obliterating vasculopathy at delayed phase.

  7. Diagnostic accuracy of contrast-enhanced spectral mammography in comparison to conventional full-field digital mammography in a population of women with dense breasts.

    Science.gov (United States)

    Mori, Miki; Akashi-Tanaka, Sadako; Suzuki, Satoko; Daniels, Murasaki Ikeda; Watanabe, Chie; Hirose, Masanori; Nakamura, Seigo

    2017-01-01

    Contrast-enhanced spectral mammography to compare clinical efficacy of contrast-enhanced spectral mammography (CESM) and conventional digital mammography (MMG) with histopathology as gold standard in dense breasts. A total of 143 breasts of 72 women who underwent CESM and MMG between 2011 and 2014 at Showa University Hospital were analyzed. 129 (90.2 %) of 143 breasts revealed dense breasts on MMG. 58 (40.6 %) of 143 breasts were diagnosed with breast cancer at histopathology. The remaining 85 breasts were diagnosed with benign findings after image assessments and/or core needle biopsy. CESM revealed 8 false-negative cases among 58 breast cancer cases (sensitivity 86.2 %) and 5 false-positive cases (specificity 94.1 %). Accuracy was 90.9 %. Conventional MMG was assessed true positive in 31 of 58 breast cancer cases (sensitivity 53.4 %) and false positive in 12 cases (specificity 85.9 %). Accuracy was 72.7 %. Sensitivity (p < 0.001), specificity (p = 0.016) and accuracy (p < 0.001) were significantly higher on CESM compared to MMG. MMG missed malignancy in 27 breasts. Of these, 25 were dense breasts. Of these 25, 20 (80.0 %) breasts were positive on CESM. These findings suggest that CESM offers superior clinical performance compared to MMG. Use of CESM may decrease false negatives especially for women with dense breasts.

  8. Contrast-Enhanced Ultrasound as a New Investigative Tool in Diagnostic Imaging of Muscle Injuries-A Pilot Study Evaluating Conventional Ultrasound, CEUS, and Findings in MRI.

    Science.gov (United States)

    Hotfiel, Thilo; Heiss, Rafael; Swoboda, Bernd; Kellermann, Marion; Gelse, Kolja; Grim, Casper; Strobel, Deike; Wildner, Dane

    2017-07-11

    To emphasize the diagnostic value of contrast-enhanced ultrasound (CEUS) in the imaging of muscle injuries with different degrees of severity by comparing findings to established imaging modalities such as conventional ultrasound and magnetic resonance imaging (MRI). Case series. Institutional study. Conventional ultrasound and CEUS were performed in the Department of Internal Medicine. Magnetic resonance imaging was carried out in the Department of Radiology within the Magnetom Avanto 1.5T and Magnetom Skyra fit 3T (Siemens Healthineers, Erlangen, Germany) and in the Institution of Imaging Diagnostics and Therapy (Magnetom Avanto 1.5T; Siemens, Erlangen, Germany). Fifteen patients who underwent an acute muscle injury were recruited. The appearance and detectable size of muscle injuries were compared between each imaging modality. The injuries were assessed by 3 independent observers and blinded between imaging modalities. All 15 injuries were identified on MRI and CEUS, whereas 10 injuries showed abnormalities in conventional ultrasound. The determination and measurement revealed significant differences between conventional ultrasound and CEUS depending on injury severity. Contrast-enhanced ultrasound revealed an impairment of microcirculation in grade I lesions (corresponding to intramuscular edema observed in MRI), which was not detectable using conventional ultrasound. Our results indicate that performing CEUS seems to be a sensitive additional diagnostic modality in the early assessment of muscle injuries. Our results highlight the advantages of CEUS in the imaging of low-grade lesions when compared with conventional ultrasound, as this was the more accurate modality for identifying intramuscular edema.

  9. Prevalence of first-pass myocardial perfusion defects detected by contrast-enhanced dual-source CT in patients with non-ST segment elevation acute coronary syndromes

    Energy Technology Data Exchange (ETDEWEB)

    Schepis, Tiziano; Achenbach, Stephan; Marwan, Mohamed; Muschiol, Gerd; Ropers, Dieter; Daniel, Werner G.; Pflederer, Tobias [University of Erlangen, Department of Internal Medicine 2 (Cardiology), Erlangen (Germany)

    2010-07-15

    To investigate the prevalence and diagnostic value of first-pass myocardial perfusion defects (PD) visualised by contrast-enhanced multidetector computed tomography (MDCT) in patients admitted for a first acute coronary syndrome (ACS). Thirty-eight patients with non-ST segment elevation myocardial infarction (NSTEMI) or unstable angina (UA) and scheduled for percutaneous coronary intervention underwent dual-source CT immediately before catheterisation. CT images were analysed for the presence of any PD by using a 17-segment model. Results were compared with peak cardiac troponin-I (cTnI) and angiography findings. PD were seen in 21 of the 24 patients with NSTEMI (median peak cTnI level 7.07 ng/mL; range 0.72-37.07 ng/mL) and in 2 of 14 patients with UA. PD corresponded with the territory of the infarct-related artery in 20 out of 22 patients. In a patient-based analysis, sensitivity, specificity, negative and positive predictive values of any PD for predicting NSTEMI were 88%, 86%, 80% and 91%. Per culprit artery, the respective values were 86%, 75%, 80% and 83%. In patients with non-ST segment elevation ACS, first-pass myocardial PD in contrast-enhanced MDCT correlate closely with the presence of myocardial necrosis, as determined by increases in cTnI levels. (orig.)

  10. First experiences with contrast-enhanced first-pass MR perfusion imaging in patients with primary, benign cardiac masses and tumour-like lesions

    Energy Technology Data Exchange (ETDEWEB)

    Mohrs, Oliver K. [Darmstadt Radiology, Department of Cardiovascular Imaging at Alice-Hospital, Darmstadt (Germany); German Cancer Research Center (DKFZ), Department of Radiology, Heidelberg (Germany); Voigtlaender, Thomas [Cardiovascular Center Bethanien (CCB), Frankfurt/Main (Germany); Petersen, Steffen E. [John Radcliffe Hospital, University of Oxford, OCMR, Oxford (United Kingdom); Zander, Matthias [Darmstadt Center of Cardiology, Darmstadt (Germany); Schulze, Thomas [Siemens Medical Solutions, Frankfurt/Main (Germany); Pottmeyer, Anselm [Darmstadt Radiology, Department of Cardiovascular Imaging at Alice-Hospital, Darmstadt (Germany); Kauczor, Hans-Ulrich [German Cancer Research Center (DKFZ), Department of Radiology, Heidelberg (Germany)

    2008-08-15

    The aim of this study was to evaluate the diagnostic value of contrast-enhanced first-pass perfusion MRI in patients with suspected cardiac masses and tumour-like lesions. Twenty patients underwent contrast-enhanced first-pass saturation-recovery steady-state-free-precession perfusion MRI in addition to clinical MRI. Eleven diagnostic parameters were analysed blinded in consensus by three observers: localisation (paracardiac/mural/intracavitary), malignancy (benign/malignant) and first-pass enhancement pattern (homogeneous/heterogeneous as well as non-perfused/hypoperfused/iso-perfused/ hyperperfused). The results were compared to combined references comprising histology, cytology, medical and surgical reports, echocardiography, chest X-ray, coronary angiography and regular MRI. Also, we analysed if additional first-pass perfusion confirmed, changed or reduced the number of differential diagnoses compared to clinical MRI. All cardiac masses or tumour-like lesions were correctly localised and scored as benign lesions. For homogeneous perfused lesions the sensitivity, specificity, positive and negative predictive value was 94/100/100/67%, 100/94/67/100% for heterogeneous perfused lesions, 92/100/100/88% for non-perfused, 100/94/75/100 for hypoperfused, 100/100/100/100% for hyperperfused and for isoperfused lesions. In 17/2/1 cases perfusion MRI confirmed, reduced or increased the number of potential differentials. First-pass perfusion MRI provides valuable information in patients with benign cardiac masses or tumour-like lesions. Further experience is needed to underline these preliminary observations. (orig.)

  11. Contrast enhanced MR findings of lesions associated with radial scar: correlation with histopathology

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Jee Woo; Cha, Eun Suk; Choi, Hyun Joo; Seo, Young Jin [College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of)

    2007-01-15

    To evaluate the contrast-enhanced MR findings of lesions associated with a radial scar and to compare the MR findings with the histopathology results. From Mar. 2001 to Sep. 2005, 8 patients with a surgically proven radial scar who had undergone MRI, mammography, and ultrasonography were enrolled in this study. The morphological findings and dynamic enhancement pattern of the time-intensity curve were retrospectively reviewed using noncontrast and contrast-enhanced MRI. Mammography and ultrasonography were also analyzed according to the BI-RADS category and correlated with the histopathological diagnosis. The age of the patients ranged from 42 to 53 years (mean, 47 years). Five patients presented with a left breast lesion and the others presented with a right breast lesion. The histopathological diagnosis associated with the radial scar were fibrocystic changes (n = 1) adenosis (n = 2), atypical ductal hyperplasia (n = 2), lobular carcinoma in situ (n = 1), ductal carcinoma in situ (n = 1), and invasive ductal carcinoma (n = 1). In all patients, architectural distortion without microcalcification was observed with mammography. Irregular shaped hypoechoic lesions with an indistinct, spiculated, or angular margin was observed in all patients with ultrasonography. Posterior shadowing was observed in 4 cases. MR enhancement revealed two cases with foci enhancement (adenosis and fibrocystic change), five cases with non-mass-like focal enhancement (fibrocystic change, atypical ductal hyperplasia, lobular carcinoma in situ, ductal carcinoma in situ, invasive ductal carcinoma), and one irregular homogeneous mass enhancement (atypical ducal hyperplasia). The time-signal intensity curves are as follows: persistent type (n = 2), adenosis, and fibrocystic changes, respectively; plateu type (n = 4) one adenosis, two atypical ductal hyperplasia, and one ductal carcinoma in situ; and washout type (n = 2), lobular carcinoma in situ, and invasive ductal carcinoma, respectively

  12. Contrast-enhanced time-resolved 3-D MRA: applications in neurosurgery and interventional neuroradiology

    Energy Technology Data Exchange (ETDEWEB)

    Reinacher, Peter C.; Stracke, Paul; Reinges, Marcus H.T.; Hans, Franz J.; Krings, Timo [University Hospital of the Technical University, Department of Neurosurgery, Aachen (Germany)

    2007-07-15

    The decision-making process in the endovascular treatment of cranial dural AV fistulas and angiomas and their follow-up after treatment is usually based on conventional digital subtraction angiography (DSA). Likewise, acquiring the vascular and hemodynamic information needed for presurgical evaluation of meningiomas may necessitate DSA or different MR-based angiographic methods to assess the arterial displacement, the location of bridging veins and tumor feeders, and the degree of vascularization. New techniques of contrast-enhanced MR angiography (MRA) permit the acquisition of images with high temporal and spatial resolution. The purpose of this study was to evaluate the applicability and clinical use of a newly developed contrast-enhanced 3-D dynamic MRA protocol for neurointerventional and neurosurgical planning and decision making. With a 3-T whole-body scanner (Philips Achieva), a 3-D dynamic contrast-enhanced (MultiHance, Bracco) MRA sequence with parallel imaging, and intelligent k-space readout (keyhole and ''CENTRA'' k-space filling) was added to structural MRI in patients with meningiomas, dural arteriovenous fistulas and pial arteriovenous malformations. The sequence had a temporal resolution of 1.3 s per 3-D volume with a spatial resolution of 0.566 x 0.566 x 1.5 mm per voxel in each 3-D volume and lasted 25.2 s. DSA was performed in selected patients following MRI. In patients with arteriovenous fistulas and malformations, MRA allowed the vascular shunt to be identified and correctly classified. Hemodynamic characteristics and venous architecture were clearly demonstrated. Larger feeding arteries could be identified in all patients. In meningiomas, MRA enabled assessment of the displacement of the cerebral arteries, depiction of the tumor feeding vessels, and evaluation of the anatomy of the venous system. The extent of tumor vascularization could be assessed in all patients and correlated with the histopathological findings that

  13. Prostate cancer transrectal HIFU ablation: detection of local recurrences using T2-weighted and dynamic contrast-enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Rouviere, Olivier; Lyonnet, Denis [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urinary and Vascular Radiology, Lyon (France); Universite de Lyon, Lyon (France); Universite de Lyon 1, Faculte de medecine Lyon Nord, Lyon (France); Inserm, U556, Lyon (France); Girouin, Nicolas; Glas, Ludivine; Ben Cheikh, Alexandre [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urinary and Vascular Radiology, Lyon (France); Universite de Lyon, Lyon (France); Universite de Lyon 1, Faculte de medecine Lyon Nord, Lyon (France); Gelet, Albert [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Urology, Lyon (France); Inserm, U556, Lyon (France); Mege-Lechevallier, Florence [Hopital Edouard Herriot, Hospices Civils de Lyon, Department of Pathology, Lyon (France); Rabilloud, Muriel [Hospices Civils de Lyon, Department of Biostatistics, Lyon (France); Universite de Lyon 1, UMR CNRS, Laboratoire Biostatistiques-Sante, Pierre-Benite (France); Chapelon, Jean-Yves [Inserm, U556, Lyon (France)

    2010-01-15

    The objective was to evaluate T2-weighted (T2w) and dynamic contrast-enhanced (DCE) MRI in detecting local cancer recurrences after prostate high-intensity focused ultrasound (HIFU) ablation. Fifty-nine patients with biochemical recurrence after prostate HIFU ablation underwent T2-weighted and DCE MRI before transrectal biopsy. For each patient, biopsies were performed by two operators: operator 1 (blinded to MR results) performed random and colour Doppler-guided biopsies (''routine biopsies''); operator 2 obtained up to three cores per suspicious lesion on MRI (''targeted biopsies''). Seventy-seven suspicious lesions were detected on DCE images (n=52), T2w images (n=2) or both (n=23). Forty patients and 41 MR lesions were positive at biopsy. Of the 36 remaining MR lesions, 20 contained viable benign glands. Targeted biopsy detected more cancers than routine biopsy (36 versus 27 patients, p=0.0523). The mean percentages of positive cores per patient and of tumour invasion of the cores were significantly higher for targeted biopsies (p<0.0001). The odds ratios of the probability of finding viable cancer and viable prostate tissue (benign or malignant) at targeted versus routine biopsy were respectively 3.35 (95% CI 3.05-3.64) and 1.38 (95% CI 1.13-1.63). MRI combining T2-weighted and DCE images is a promising method for guiding post-HIFU biopsy towards areas containing recurrent cancer and viable prostate tissue. (orig.)

  14. Role of contrast-enhanced ultrasound in decision support for diagnosis and treatment of hepatic artery thrombosis after liver transplantation.

    Science.gov (United States)

    Lu, Qiang; Zhong, Xiao Fei; Huang, Zi Xing; Yu, Bo Yang; Ma, Bu Yun; Ling, Wen Wu; Wu, Hong; Yang, Jia Ying; Luo, Yan

    2012-03-01

    To assess role of contrast-enhanced ultrasound (CEUS) in decision support for diagnosis and treatment of hepatic artery thrombosis (HAT) after liver transplantation. Between January 2005 and January 2011, 605 patients underwent liver transplantation in our medical center. All the liver transplant recipients received Doppler ultrasound scanning and CEUS examination was performed in 45 patients with suspected HAT on Doppler ultrasound. Sensitivity, specificity, accuracy, positive predict value and negative predictive value of CEUS in diagnosing HAT were determined based on the results from angiography, surgery and clinical follow-up. Fourteen HATs, including one late HAT, were diagnosed by CEUS. Twelve HAT cases were confirmed by angiographic and/or surgical findings, while the late HAT and other 31 patients with negative CEUS finding were confirmed by the clinical follow-up. There was a false positive HAT diagnosed by CEUS in which angiography revealed a patent hepatic artery. The sensitivity, specificity, accuracy, positive predict value and negative predictive value of CEUS in diagnosing HAT were 100%, 96.9%, 97.8%, 92.9% and 100%, respectively. In our series of 605 liver transplants, the incidence and mortality of HAT was 2.2% (13/605) and 53.8% (7/13), respectively. Our study demonstrates the important role of CEUS in decision support for diagnosis and treatment of HAT after liver transplantation. When HAT is suspected by Doppler ultrasound, CEUS shall immediately be performed to elucidate its nature. A negative CEUS finding shall avoid invasive angiography. Such as, CEUS may alter the clinical workflow on HAT detection after liver transplantation. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  15. Hepatic Blood Perfusion Estimated by Dynamic Contrast-Enhanced Computed Tomography in Pigs Limitations of the Slope Method

    Science.gov (United States)

    Winterdahl, Michael; Sørensen, Michael; Keiding, Susanne; Mortensen, Frank V.; Alstrup, Aage K. O.; Hansen, Søren B.; Munk, Ole L.

    2012-01-01

    Objective To determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates. Materials and Methods Ten anesthetized 40-kg pigs underwent DCE-CT during periods of normocapnia (normal flow), hypocapnia (decreased flow), and hypercapnia (increased flow), which was induced by adjusting the ventilation. Reference blood flows in HA and PV were measured continuously by surgically-placed ultrasound transit-time flowmeters. For each capnic condition, the DCE-CT estimated absolute hepatic blood perfusion from HA and PV were calculated using the slope method and compared with flowmeter based absolute measurements of hepatic perfusions and relative errors were analyzed. Results The relative errors (mean±SEM) of the DCE-CT based perfusion estimates were −21±23% for HA and 81±31% for PV (normocapnia), 9±23% for HA and 92±42% for PV (hypocapnia), and 64±28% for HA and −2±20% for PV (hypercapnia). The mean relative errors for HA were not significantly different from zero during hypo- and normocapnia, and the DCE-CT slope method could detect relative changes in HA perfusion between scans. Infusion of contrast agent led to significantly increased hepatic blood perfusion, which biased the PV perfusion estimates. Conclusions Using the DCE-CT slope method, HA perfusion estimates were accurate at low and normal flow rates whereas PV perfusion estimates were inaccurate and imprecise. At high flow rate, both HA perfusion estimates were significantly biased. PMID:22836307

  16. Hepatic blood perfusion estimated by dynamic contrast-enhanced computed tomography in pigs: limitations of the slope method.

    Science.gov (United States)

    Winterdahl, Michael; Sørensen, Michael; Keiding, Susanne; Mortensen, Frank V; Alstrup, Aage K O; Hansen, Søren B; Munk, Ole L

    2012-10-01

    The aim of this study was to determine whether dynamic contrast-enhanced computed tomography (DCE-CT) and the slope method can provide absolute measures of hepatic blood perfusion from the hepatic artery (HA) and portal vein (PV) at experimentally varied blood flow rates. Ten anesthetized 40-kg pigs underwent DCE-CT of the liver during periods of normocapnia (normal flow), hypocapnia (decreased flow), and hypercapnia (increased flow), which were induced by adjusting the ventilation. Reference blood flows in the HA and PV were measured continuously by surgically placed ultrasound transit-time flowmeters. For each capnic condition, the DCE-CT-estimated absolute hepatic blood perfusion from the HA and PV were calculated using the slope method and compared with flowmeter-based absolute measurements of hepatic perfusions and relative errors were analyzed. The relative errors (mean ± SEM) of the DCE-CT based perfusion estimates were -21% ± 23% for HA and 81% ± 31% for PV during normocapnia, 9% ± 23% for HA and 92% ± 42% for PV during hypocapnia, and 64% ± 28% for HA and -2% ± 20% for PV during hypercapnia. The mean relative errors for HA were not significantly different from 0 during hypocapnia and normocapnia, and the DCE-CT slope method could detect relative changes in HA perfusion between scans. Infusion of contrast agent led to significantly increased hepatic blood perfusion, which biased the PV perfusion estimates. Using the DCE-CT slope method, HA perfusion estimates were accurate at low and normal flow rates, whereas PV perfusion estimates were inaccurate and imprecise. At high flow rate, both HA perfusion estimates were significantly biased.

  17. Suitability of pharmacokinetic models for dynamic contrast-enhanced MRI of abdominal aortic aneurysm vessel wall: a comparison.

    Directory of Open Access Journals (Sweden)

    V Lai Nguyen

    Full Text Available PURPOSE: Increased microvascularization of the abdominal aortic aneurysm (AAA vessel wall has been related to AAA progression and rupture. The aim of this study was to compare the suitability of three pharmacokinetic models to describe AAA vessel wall enhancement using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI. MATERIALS AND METHODS: Patients with AAA underwent DCE-MRI at 1.5 Tesla. The volume transfer constant (K(trans , which reflects microvascular flow, permeability and surface area, was calculated by fitting the blood and aneurysm vessel wall gadolinium concentration curves. The relative fit errors, parameter uncertainties and parameter reproducibilities for the Patlak, Tofts and Extended Tofts model were compared to find the most suitable model. Scan-rescan reproducibility was assessed using the interclass correlation coefficient and coefficient of variation (CV. Further, the relationship between K(trans and AAA size was investigated. RESULTS: DCE-MRI examinations from thirty-nine patients (mean age±SD: 72±6 years; M/F: 35/4 with an mean AAA maximal diameter of 49±6 mm could be included for pharmacokinetic analysis. Relative fit uncertainties for K(trans based on the Patlak model (17% were significantly lower compared to the Tofts (37% and Extended Tofts model (42% (p<0.001. K(trans scan-rescan reproducibility for the Patlak model (ICC = 0.61 and CV = 22% was comparable with the Tofts (ICC = 0.61, CV = 23% and Extended Tofts model (ICC = 0.76, CV = 22%. K(trans was positively correlated with maximal AAA diameter (Spearman's ρ = 0.38, p = 0.02 using the Patlak model. CONCLUSION: Using the presented imaging protocol, the Patlak model is most suited to describe DCE-MRI data of the AAA vessel wall with good K(trans scan-rescan reproducibility.

  18. Quantitative analysis of contrast-enhanced ultrasonography of the bowel wall can predict disease activity in inflammatory bowel disease

    Energy Technology Data Exchange (ETDEWEB)

    Romanini, Laura, E-mail: laura.romanini@libero.it [Department of Radiology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Passamonti, Matteo, E-mail: matteopassamonti@gmail.com [Department of Radiology-AO Provincia di Lodi, Via Fissiraga, 15, 26900 Lodi (Italy); Navarria, Mario, E-mail: navarria.mario@tiscali.it [Department of Radiology-ASL Vallecamonica-Sebino, Via Manzoni 142, 25040 Esine, BS (Italy); Lanzarotto, Francesco, E-mail: francesco.lanzarotto@spedalicivili.brescia.it [Department of Gastroenterology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Villanacci, Vincenzo, E-mail: villanac@alice.it [Department of Pathology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Grazioli, Luigi, E-mail: radiologia1@spedalicivili.brescia.it [Department of Radiology, Spedali Civili di Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy); Calliada, Fabrizio, E-mail: fabrizio.calliada@gmail.com [Department of Radiology, University of Pavia, Viale Camillo Golgi 19, 27100 Pavia (Italy); Maroldi, Roberto, E-mail: rmaroldi@gmail.com [Department of Radiology, University of Brescia, P.le Spedali Civili, 1, 25123 Brescia (Italy)

    2014-08-15

    Purpose: To evaluate the accuracy of quantitative analysis of bowel wall enhancement in inflammatory bowel disease (IBD) with contrast enhanced ultrasound (CEUS) by comparing the results with vascular density in a biopsy sample from the same area of the intestinal tract, and to determine the usefulness of this analysis for the prediction of disease activity. Materials and methods: This prospective study was approved by our institute's ethics committee and all patients gave written informed consent. We enrolled 33 consecutive adult patients undergoing colonoscopy and biopsy for IBD. All patients underwent CEUS and the results were quantitatively analyzed. Vessel count per high-power field on biopsy specimens was compared with colonoscopy, baseline ultrasonography, and CEUS findings, and with analysis of peak intensity, time to peak, regional blood volume, mean transit time, and regional blood flow. Results in patients with high and low vascular density were compared using Fisher's test, t-test, Pearson's correlation test, and receiver operating characteristic curve (ROC) analysis. Cutoff values were determined using ROC analysis, and sensitivity and specificity were calculated. Results: High vascular density (>265 vessels per field) on histological examination was significantly correlated with active disease on colonoscopy, baseline ultrasonography, and CEUS (p < .0001). Quantitative analysis showed a higher enhancement peak, a shorter time to peak enhancement, a higher regional blood flow and regional blood volume in patients with high vascular density than in those with low vascular density. Cutoff values to distinguish between active and inactive disease were identified for peak enhancement (>40.5%), and regional blood flow (>54.8 ml/min). Conclusion: Quantitative analysis of CEUS data correlates with disease activity as determined by vascular density. Quantitative parameters of CEUS can be used to predict active disease with high sensitivity and

  19. Dynamic contrast-enhanced magnetic resonance imaging can assess vascularity within fracture non-unions and predicts good outcome

    Energy Technology Data Exchange (ETDEWEB)

    Schoierer, Oliver; Bender, Daniel; Schmidmaier, Gerhard [University Hospital Heidelberg, Heidelberg Trauma Research Group, Department of Orthopaedic and Trauma Surgery, Heidelberg (Germany); Bloess, Konstantin; Kauczor, Hans-Ulrich; Weber, Marc-Andre [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Burkholder, Iris [University of Applied Sciences of the Saarland, Department of Nursing and Health, Saarbruecken (Germany)

    2014-02-15

    To prospectively evaluate whether dynamic contrast-enhanced (DCE) MRI can assess vascularity within non-unions and predicts clinical outcome in combination with the clinical Non-Union Scoring System (NUSS). Fifty-eight patients with non-unions of extremities on CT underwent 3-T DCE MRI. Signal intensity curves obtained from a region-of-interest analysis were subdivided into those with more intense contrast agent uptake within the non-union than in adjacent muscle (vascularised non-union) and those with similar or less contrast uptake. The pharmacokinetic parameters of the Tofts model K{sub trans}, K{sub ep}, iAUC and V{sub e} were correlated with union at CT 1 year later (n = 49). Despite inserted osteosynthetic material, DCE parameters could be evaluated in 57 fractures. The sensitivity/specificity of vascularised non-unions as an indicator of good outcome was 83.9 %/50.0 % compared to 96.8 %/33.3 % using NUSS (n = 49). Logistic regression revealed a significant impact of NUSS on outcome (P = 0.04, odds ratio = 0.93). At first examination, median iAUC (initial area under the enhancement curve) for the ratio non-union/muscle was 10.28 in patients with good outcome compared with 3.77 in non-responders (P = 0.023). K{sub trans}, K{sub ep} and V{sub e} within the non-union were not significantly different initially (n = 57) or 1 year later (n = 19). DCE MRI can assess vascularity in fracture non-unions. A vascularised non-union correlates with good outcome. (orig.)

  20. Response Assessment in Neuro-Oncology criteria, contrast enhancement and perfusion MRI for assessing progression in glioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Tensaouti, Fatima [Universite de Toulouse, Inserm, UPS, ToNIC, Toulouse NeuroImaging Center, Toulouse (France); Khalifa, Jonathan [Claudius Regaud Institute / Toulouse University Cancer Institute - Oncopole, Department of Radiation Oncology, Toulouse (France); Lusque, Amelie [Claudius Regaud Institute / Toulouse University Cancer Institute - Oncopole, Department of Biostatistics, Toulouse (France); Plas, Benjamin [CHU Toulouse, Department of Neurosurgery, Toulouse (France); Lotterie, Jean Albert; Berry, Isabelle [Universite de Toulouse, Inserm, UPS, ToNIC, Toulouse NeuroImaging Center, Toulouse (France); CHU Toulouse, Department of Nuclear Medicine, Toulouse (France); Laprie, Anne [Universite de Toulouse, Inserm, UPS, ToNIC, Toulouse NeuroImaging Center, Toulouse (France); Claudius Regaud Institute / Toulouse University Cancer Institute - Oncopole, Department of Radiation Oncology, Toulouse (France); Cohen-Jonathan Moyal, Elizabeth [Claudius Regaud Institute / Toulouse University Cancer Institute - Oncopole, Department of Radiation Oncology, Toulouse (France); Toulouse Center for Cancer Research (U1037), Inserm, Toulouse (France); Lubrano, Vincent [Universite de Toulouse, Inserm, UPS, ToNIC, Toulouse NeuroImaging Center, Toulouse (France); CHU Toulouse, Department of Neurosurgery, Toulouse (France)

    2017-10-15

    The purpose of the study was to evaluate Response Assessment in Neuro-Oncology (RANO) criteria in glioblastoma multiforme (GBM), with respect to the Macdonald criteria and changes in contrast-enhancement (CE) volume. Related variations in relative cerebral blood volume (rCBV) were investigated. Forty-three patients diagnosed between 2006 and 2010 were included. All underwent surgical resection, followed by temozolomide-based chemoradiation. MR images were retrospectively reviewed. Times to progression (TTPs) according to RANO criteria, Macdonald criteria and increased CE volume (CE-3D) were compared, and the percentage change in the 75th percentile of rCBV (rCBV75) was evaluated. After a median follow-up of 22.7 months, a total of 39 patients had progressed according to RANO criteria, 32 according to CE-3D, and 42 according to Macdonald. Median TTPs were 6.4, 9.3, and 6.6 months, respectively. Overall agreement was 79.07% between RANO and CE-3D and 93.02% between RANO and Macdonald. The mean percentage change in rCBV75 at RANO progression onset was over 73% in 87.5% of patients. In conclusion, our findings suggest that CE-3D criterion is not yet suitable to assess progression in routine clinical practice. Indeed, the accurate threshold is still not well defined. To date, in our opinion, early detection of disease progression by RANO combined with advanced MRI imaging techniques like MRI perfusion and diffusion remains the best way to assess disease progression. Further investigations that would examine the impact of treatment modifications after progression determined by different criteria on overall survival would be of great value. (orig.)

  1. Contrast-enhanced magnetic resonance mammography: does it affect surgical decision-making in patients with breast cancer?

    Science.gov (United States)

    Pediconi, Federica; Catalano, Carlo; Padula, Simona; Roselli, Antonella; Moriconi, Enrica; Dominelli, Valeria; Pronio, Anna Maria; Kirchin, Miles A; Passariello, Roberto

    2007-11-01

    Diagnostic imaging in women with suspected breast cancer should accurately detect and diagnose malignant tumors and facilitate the correct choice of therapy. Contrast-enhanced magnetic resonance mammography (CE-MRM) is potentially the imaging modality of choice for accurate patient management decisions. A total of 164 women with suspected breast cancer based on clinical examination, conventional mammography and/or ultrasound each underwent preoperative bilateral CE-MRM using an axial 3D dynamic T1-weighted gradient-echo sequence and gadobenate dimeglumine as contrast agent. Images were evaluated by two readers in consensus. Histological evaluation of detected lesions was performed on samples from core biopsy or surgery. Determinations were made of the sensitivity, accuracy and positive predictive value of CE-MRM compared to mammography/ultrasound for the detection of malignant lesions and of the impact of CE-MRM for surgical decision-making. Conventional mammography/ultrasound detected 175 lesions in the 164 evaluated patients. CE-MRM revealed 51 additional lesions in 34/164 patients; multifocal and multicentric cancer was detected in 7 and 4 additional patients, respectively, contralateral foci in 21 additional patients and pectoral muscle infiltration in 2 additional patients. CE-MRM also confirmed the absence or benignity of 3 and 1 lesions suspected of malignancy on mammography/ultrasound. The sensitivity and accuracy for malignant lesion detection and identification was 100% and 93.4%, respectively, for CE-MRM compared to 77.3% and 72.1% for mammography/ultrasound, respectively. Patient management was altered for 32/164 (19.5%) patients as a result of CE-MRM. CE-MRM positively impacts patient management decisions and should be performed in all women with suspected breast cancer based on clinical examination, mammography and/or ultrasound.

  2. Contrast-enhanced spectral mammography: Does mammography provide additional clinical benefits or can some radiation exposure be avoided?

    Science.gov (United States)

    Fallenberg, Eva Maria; Dromain, Clarisse; Diekmann, Felix; Renz, Diane M; Amer, Heba; Ingold-Heppner, Barbara; Neumann, Avidan U; Winzer, Klaus J; Bick, Ulrich; Hamm, Bernd; Engelken, Florian

    2014-07-01

    The purpose of this study was to compare contrast-enhanced spectral mammography (CESM) with mammography (MG) and combined CESM + MG in terms of detection and size estimation of histologically proven breast cancers in order to assess the potential to reduce radiation exposure. A total of 118 patients underwent MG and CESM and had final histological results. CESM was performed as a bilateral examination starting 2 min after injection of iodinated contrast medium. Three independent blinded radiologists read the CESM, MG, and CESM + MG images with an interval of at least 4 weeks to avoid case memorization. Sensitivity and size measurement correlation and differences were calculated, average glandular dose (AGD) levels were compared, and breast densities were reported. Fisher's exact and Wilcoxon tests were performed. A total of 107 imaging pairs were available for analysis. Densities were ACR1: 2, ACR2: 45, ACR3: 42, and ACR4: 18. Mean AGD was 1.89 mGy for CESM alone, 1.78 mGy for MG, and 3.67 mGy for the combination. In very dense breasts, AGD of CESM was significantly lower than MG. Sensitivity across readers was 77.9 % for MG alone, 94.7 % for CESM, and 95 % for CESM + MG. Average tumor size measurement error compared to postsurgical pathology was -0.6 mm for MG, +0.6 mm for CESM, and +4.5 mm for CESM + MG (p < 0.001 for CESM + MG vs. both modalities). CESM alone has the same sensitivity and better size assessment as CESM + MG and was significantly better than MG with only 6.2 % increase in AGD. The combination of CESM + MG led to systematic size overestimation. When a CESM examination is planned, additional MG can be avoided, with the possibility of saving up to 61 % of radiation dose, especially in patients with dense breasts.

  3. Evaluation of Liver Fibrosis Using Texture Analysis on Combined-Contrast-Enhanced Magnetic Resonance Images at 3.0T

    Directory of Open Access Journals (Sweden)

    Takeshi Yokoo

    2015-01-01

    Full Text Available Purpose. To noninvasively assess liver fibrosis using combined-contrast-enhanced (CCE magnetic resonance imaging (MRI and texture analysis. Materials and Methods. In this IRB-approved, HIPAA-compliant prospective study, 46 adults with newly diagnosed HCV infection and recent liver biopsy underwent CCE liver MRI following intravenous administration of superparamagnetic iron oxides (ferumoxides and gadolinium DTPA (gadopentetate dimeglumine. The image texture of the liver was quantified in regions-of-interest by calculating 165 texture features. Liver biopsy specimens were stained with Masson trichrome and assessed qualitatively (METAVIR fibrosis score and quantitatively (% collagen stained area. Using L1 regularization path algorithm, two texture-based multivariate linear models were constructed, one for quantitative and the other for quantitative histology prediction. The prediction performance of each model was assessed using receiver operating characteristics (ROC and correlation analyses. Results. The texture-based predicted fibrosis score significantly correlated with qualitative (r=0.698, P<0.001 and quantitative (r=0.757, P<0.001 histology. The prediction model for qualitative histology had 0.814–0.976 areas under the curve (AUC, 0.659–1.000 sensitivity, 0.778–0.930 specificity, and 0.674–0.935 accuracy, depending on the binary classification threshold. The prediction model for quantitative histology had 0.742–0.950 AUC, 0.688–1.000 sensitivity, 0.679–0.857 specificity, and 0.696–0.848 accuracy, depending on the binary classification threshold. Conclusion. CCE MRI and texture analysis may permit noninvasive assessment of liver fibrosis.

  4. Dynamic contrast enhanced-MRI for the detection of pathological complete response to neoadjuvant chemotherapy for locally advanced rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Gollub, M.J.; Gultekin, D.H.; Akin, O.; Do, R.K.; Fuqua, J.L. [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States); Gonen, M.; Kuk, D. [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Weiser, M.; Paty, P.; Guillem, J.; Nash, G.M.; Temple, L. [Memorial Sloan-Kettering Cancer Center, Department of Surgery, New York, NY (United States); Saltz, L. [Memorial Sloan-Kettering Cancer Center, Department of Medicine, New York, NY (United States); Schrag, D. [Dana Farber Cancer Institute, Boston, MA (United States); Goodman, K. [Memorial Sloan-Kettering Cancer Center, Department of Radiation Oncology, New York, NY (United States); Shia, J. [Memorial Sloan-Kettering Cancer Center, Department of Pathology, New York, NY (United States); Schwartz, L.H. [Columbia University Medical Center/New York Presbyterian Hospital, Department of Radiology, New York, NY (United States)

    2012-04-15

    To determine the ability of dynamic contrast enhanced (DCE-MRI) to predict pathological complete response (pCR) after preoperative chemotherapy for rectal cancer. In a prospective clinical trial, 23/34 enrolled patients underwent pre- and post-treatment DCE-MRI performed at 1.5T. Gadolinium 0.1 mmol/kg was injected at a rate of 2 mL/s. Using a two-compartmental model of vascular space and extravascular extracellular space, K{sup trans}, k{sub ep}, v{sub e}, AUC90, and AUC180 were calculated. Surgical specimens were the gold standard. Baseline, post-treatment and changes in these quantities were compared with clinico-pathological outcomes. For quantitative variable comparison, Spearman's Rank correlation was used. For categorical variable comparison, the Kruskal-Wallis test was used. P {<=} 0.05 was considered significant. Percentage of histological tumour response ranged from 10 to 100%. Six patients showed pCR. Post chemotherapy K{sup trans} (mean 0.5 min{sup -1} vs. 0.2 min{sup -1}, P = 0.04) differed significantly between non-pCR and pCR outcomes, respectively and also correlated with percent tumour response and pathological size. Post-treatment residual abnormal soft tissue noted in some cases of pCR prevented an MR impression of complete response based on morphology alone. After neoadjuvant chemotherapy in rectal cancer, MR perfusional characteristics have been identified that can aid in the distinction between incomplete response and pCR. (orig.)

  5. Assessing tumor extent on contrast-enhanced spectral mammography versus full-field digital mammography and ultrasound.

    Science.gov (United States)

    Patel, Bhavika K; Garza, Sandr