WorldWideScience

Sample records for stripper tower bottoms

  1. Spectrolog microprocessor stripper

    International Nuclear Information System (INIS)

    Angehrn, J.A.; Groeschel, V.E.

    1981-01-01

    Gamma spectrum measurement signals received from a downhole instrument containing a scintillation counter are coupled into a multi-channel analyzer, which converts them to pulses in separate channels according to signal energy levels. The analyzer energy channels are coupled to digital decoders set up for energy level windows for preselected elements, and for the total occurrence count. These outputs are coupled into a microprocessor stripper which includes storage comparison registers sized in accordance with the logging rate and crystal utilized in the scintillation counter. These registers permit filtering in addition to stripping the various energy channels of the influence radiation caused by the elements having an energy band centered around a higher energy level. After the stripping occurs, the outputs for each of the selected energy channels may be coupled into a digital recorder or into count rate meters for conversion to analog voltages for driving a chart recorder. (author)

  2. Modelling fluidized catalytic cracking unit stripper efficiency

    OpenAIRE

    García-Dopico M.; García A.

    2015-01-01

    This paper presents our modelling of a FCCU stripper, following our earlier research. This model can measure stripper efficiency against the most important variables: pressure, temperature, residence time and steam flow. Few models in the literature model the stripper and usually they do against only one variable. Nevertheless, there is general agreement on the importance of the stripper in the overall process, and the fact that there are few models maybe i...

  3. What You Should Know about Using Paint Strippers

    Science.gov (United States)

    ... in the developing fetus have been noted in laboratory animals exposed to some of the chemicals in paint strippers. Therefore, women of child-bearing age who work with or use paint strippers on a regular basis, such as ...

  4. Development of stripper options for FRIB

    Energy Technology Data Exchange (ETDEWEB)

    Marti, F.; Hershcovitch, A.; Momozaki, Y.; Nolen, J.; Reed, C.; Thieberger, P.

    2010-09-12

    The US Department of Energy Facility for Rare Isotope Beams (FRIB) at Michigan State University includes a heavy ion superconducting linac capable of accelerating all ions up to uranium with energies higher than 200 MeV/u and beam power up to 400 kW. To achieve these goals with present ion source performance it is necessary to accelerate simultaneously two charge states of uranium from the ion source in the first section of the linac. At an energy of approximately 16.5 MeV/u it is planned to strip the uranium beam to reduce the voltage needed in the rest of the linac to achieve the final energy. Up to five different charge states are planned to be accelerated simultaneously after the stripper. The design of the stripper is a challenging problem due to the high power deposited (approximately 0.7 kW) in the stripper media by the beam in a small spot. To assure success of the project we have established a research and development program that includes several options: carbon or diamond foils, liquid lithium films, gas strippers and plasma strippers. We present in this paper the status of the different options.

  5. Consortium for Petroleum & Natural Gas Stripper Wells

    Energy Technology Data Exchange (ETDEWEB)

    Joel L. Morrison; Sharon L. Elder

    2007-03-31

    The Pennsylvania State University, under contract to the U.S. Department of Energy (DOE), National Energy Technology Laboratory (NETL), established a national industry-driven Stripper Well Consortium (SWC) that is focused on improving the production performance of domestic petroleum and/or natural gas stripper wells. The SWC represents a partnership between U.S. petroleum and natural gas producers, trade associations, state funding agencies, academia, and the NETL. This document serves as the twelfth quarterly technical progress report for the SWC. Key activities for this reporting period included: (1) Drafting and releasing the 2007 Request for Proposals; (2) Securing a meeting facility, scheduling and drafting plans for the 2007 Spring Proposal Meeting; (3) Conducting elections and announcing representatives for the four 2007-2008 Executive Council seats; (4) 2005 Final Project Reports; (5) Personal Digital Assistant Workshops scheduled; and (6) Communications and outreach.

  6. Lifetime measurements on carbon stripper foils

    International Nuclear Information System (INIS)

    Auble, R.L.; Galbraith, D.M.

    1981-01-01

    One of the most exciting recent developments in accelerator technology is the new breed of electrostatic accelerators. These machines have terminal potentials of 25 million volts and higher and are being built to accelerate intense beams of heavy ions. One such accelerator is now nearing completion at ORNL. A crucial component in these--as in any electrostatic accelerator--is a tiny bit of carbon in the form of a very thin foil. These foils, called stripper foils, are used to strip electrons from atoms so that they will be accelerated to high energy by the electrostatic potential. While carbon foils are not the only method of stripping electrons, they have a number of advantages over the alternative gas strippers. In particular, they produce higher charge states which are essential for providing the energetic ions required for heavy ion physics experiments. Because of the importance of stripper foils to the most efficient operation of the new ORNL accelerator, we are quite interested in their properties and in improving their performance

  7. Consortium for Petroleum & Natural Gas Stripper Wells

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Joel [Pennsylvania State Univ., University Park, PA (United States)

    2011-12-01

    The United States has more oil and gas wells than any other country. As of December 31, 2004, there were more than half a million producing oil wells in the United States. That is more than three times the combined total for the next three leaders: China, Canada, and Russia. The Stripper Well Consortium (SWC) is a partnership that includes domestic oil and gas producers, service and supply companies, trade associations, academia, the Department of Energy’s Strategic Center for Natural Gas and Oil (SCNGO) at the National Energy Technology Laboratory (NETL), and the New York State Energy Research and Development Authority (NYSERDA). The Consortium was established in 2000. This report serves as a final technical report for the SWC activities conducted over the May 1, 2004 to December 1, 2011 timeframe. During this timeframe, the SWC worked with 173 members in 29 states and three international countries, to focus on the development of new technologies to benefit the U.S. stripper well industry. SWC worked with NETL to develop a nationwide request-for-proposal (RFP) process to solicit proposals from the U.S. stripper well industry to develop and/or deploy new technologies that would assist small producers in improving the production performance of their stripper well operations. SWC conducted eight rounds of funding. A total of 132 proposals were received. The proposals were compiled and distributed to an industry-driven SWC executive council and program sponsors for review. Applicants were required to make a formal technical presentation to the SWC membership, executive council, and program sponsors. After reviewing the proposals and listening to the presentations, the executive council made their funding recommendations to program sponsors. A total of 64 projects were selected for funding, of which 59 were fully completed. Penn State then worked with grant awardees to issue a subcontract for their approved work. SWC organized and hosted a total of 14 meetings

  8. A new gas stripper system for BARC-TIFR Pelletron Accelerator facility: installation and preliminary results

    International Nuclear Information System (INIS)

    Sharma, S.C.; Ninawe, N.G.; Yadav, M.L.; Ekambaram, M.; Ramjilal; Matkar, U.V.; Ansari, Q.N.; Lokare, R.N.; Ramlal; Gupta, A.K.; Bhagwat, P.V.; Pillay, R.G.

    2009-01-01

    The gas-stripper plays a key role in stripping the heavy and molecular ion beams in a tandem accelerator. Efficiency of gas stripper depends on its supporting vacuum pumps. A new recirculating turbo molecular pump-based gas stripper has been installed in the high voltage terminal of Pelletron Accelerator. Re-circulating the stripper gas reduces the flow of gas into the accelerating tubes reducing the transmission losses. Preliminary results obtained using the new gas stripper system are discussed. (author)

  9. Tritium glovebox stripper system seismic design evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Grinnell, J. J. [Savannah River Site (SRS), Aiken, SC (United States); Klein, J. E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-09-01

    The use of glovebox confinement at US Department of Energy (DOE) tritium facilities has been discussed in numerous publications. Glovebox confinement protects the workers from radioactive material (especially tritium oxide), provides an inert atmosphere for prevention of flammable gas mixtures and deflagrations, and allows recovery of tritium released from the process into the glovebox when a glovebox stripper system (GBSS) is part of the design. Tritium recovery from the glovebox atmosphere reduces emissions from the facility and the radiological dose to the public. Location of US DOE defense programs facilities away from public boundaries also aids in reducing radiological doses to the public. This is a study based upon design concepts to identify issues and considerations for design of a Seismic GBSS. Safety requirements and analysis should be considered preliminary. Safety requirements for design of GBSS should be developed and finalized as a part of the final design process.

  10. Cooling tower

    International Nuclear Information System (INIS)

    Baer, E.; Dittrich, H.; Ernst, G.; Roller, W.

    1975-01-01

    The task on which the invention is based is to design a cooling tower in such a way that the negative influences of the wind, in particular strong side winds (wind velocities of over 10 m/s), on the functioning of the cooling tower are reduced or eliminated altogether. (orig./TK) [de

  11. Water tower

    CERN Multimedia

    CERN PhotoLab

    1970-01-01

    The water tower, being built on the highest point of the site, 460.5 m above the sea level. The tank will hold 750 m3 of water, and the tower will be topped by a knob which can serve as a geological survey reference mark.

  12. Simulation of ion beam scattering in a gas stripper

    Science.gov (United States)

    Maxeiner, Sascha; Suter, Martin; Christl, Marcus; Synal, Hans-Arno

    2015-10-01

    Ion beam scattering in the gas stripper of an accelerator mass spectrometer (AMS) enlarges the beam phase space and broadens its energy distribution. As the size of the injected beam depends on the acceleration voltage through phase space compression, the stripper becomes a limiting factor of the overall system transmission especially for low energy AMS system in the sub MV region. The spatial beam broadening and collisions with the accelerator tube walls are a possible source for machine background and energy loss fluctuations influence the mass resolution and thus isotope separation. To investigate the physical processes responsible for these effects, a computer simulation approach was chosen. Monte Carlo simulation methods are applied to simulate elastic two body scattering processes in screened Coulomb potentials in a (gas) stripper and formulas are derived to correctly determine random collision parameters and free path lengths for arbitrary (and non-homogeneous) gas densities. A simple parametric form for the underlying scattering cross sections is discussed which features important scaling behaviors. An implementation of the simulation was able to correctly model the data gained with the TANDY AMS system at ETH Zurich. The experiment covered transmission measurements of uranium ions in helium and beam profile measurements after the ion beam passed through the He-stripper. Beam profiles measured up to very high stripper densities could be understood in full system simulations including the relevant ion optics. The presented model therefore simulates the fundamental physics of the interaction between an ion beam and a gas stripper reliably. It provides a powerful and flexible tool for optimizing existing AMS stripper geometries and for designing new, state of the art low energy AMS systems.

  13. Virtueller Tower

    OpenAIRE

    Fürstenau, Norbert

    2006-01-01

    Es wird ein Überblick über den Stand der Forschung und Entwicklung zum Remote Tower Experimentalsystem gegeben, des im Rahmen des DLR-Projekts RapTOr am Forschungsflughafen Braunschweig aufgebaut wird.

  14. Tests of prototype salt stripper system for IFR fuel cycle

    International Nuclear Information System (INIS)

    Carls, E.L.; Blaskovitz, R.J.; Johnson, T.R.; Ogata, T.

    1993-01-01

    One of the waste treatment steps for the on-site reprocessing of spent fuel from the Integral Fast Reactor fuel cycles is stripping of the electrolyte salt used in the electrorefining process. This involves the chemical reduction of the actinides and rare earth chlorides forming metals which then dissolve in a cadmium pool. To develop the equipment for this step, a prototype salt stripper system has been installed in an engineering scale argon-filled glovebox. Pumping trails were successful in transferring 90 kg of LiCl-KCl salt containing uranium and rare earth metal chlorides at 500 degree C from an electrorefiner to the stripper vessel at a pumping rate of about 5 L/min. The freeze seal solder connectors which were used to join sections of the pump and transfer line performed well. Stripping tests have commenced employing an inverted cup charging device to introduce a Cd-15 wt % Li alloy reductant to the stripper vessel

  15. Glovebox stripper system tritium capture efficiency-literature review

    Energy Technology Data Exchange (ETDEWEB)

    James, D. W. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Poore, A. S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-09-28

    Glovebox Stripper Systems (GBSS) are intended to minimize tritium emissions from glovebox confinement systems in Tritium facilities. A question was raised to determine if an assumed 99% stripping (decontamination) efficiency in the design of a GBBS was appropriate. A literature review showed the stated 99% tritium capture efficiency used for design of the GBSS is reasonable. Four scenarios were indicated for GBSSs. These include release with a single or dual stage setup which utilizes either single-pass or recirculation for stripping purposes. Examples of single-pass as well as recirculation stripper systems are presented and reviewed in this document.

  16. Radiation lifetimes and failure mechanisms of carbon stripper foils

    International Nuclear Information System (INIS)

    Auble, R.L.

    1981-01-01

    Measurements of lifetimes of thin carbon foils under heavy-ion irradiation are compiled and recent advances in stripper foil technology are reviewed. The impact of recent foil lifetime improvements, many by more than an order of magnitude, on heavy-ion electrostatic accelerators is discussed. Foil inhomogeneities, particularly those caused by sputtering are suggested to be a prime factor in usable foil lifetimes

  17. Virtual Tower

    International Nuclear Information System (INIS)

    Wayne, R.A.

    1997-01-01

    The primary responsibility of an intrusion detection system (IDS) operator is to monitor the system, assess alarms, and summon and coordinate the response team when a threat is acknowledged. The tools currently provided to the operator are somewhat limited: monitors must be switched, keystrokes must be entered to call up intrusion sensor data, and communication with the response force must be maintained. The Virtual tower is an operator interface assembled from low-cost commercial-off-the-shelf hardware and software; it enables large amounts of data to be displayed in a virtual manner that provides instant recognition for the operator and increases assessment accuracy in alarm annunciator and control systems. This is accomplished by correlating and fusing the data into a 360-degree visual representation that employs color, auxiliary attributes, video, and directional audio to prompt the operator. The Virtual Tower would be a valuable low-cost enhancement to existing systems

  18. Design and development of a chickpea stripper harvester

    Directory of Open Access Journals (Sweden)

    H. Golpira

    2013-11-01

    Full Text Available Saving cost and time was a motivation to develop a mechanized harvesting system for chickpeas, which are manually uprooted on fallow fields in developing countries. A tractor-pulled harvester with a modified stripper header was designed and fabricated, in which passive fingers with V-shaped slots removes chickpea pods from anchored plant; batted reel sweeps the pods across the platform. Field experiments were conducted to determine the effect of slot width and reel speed on machine performance in terms of harvesting losses. Minimal losses were found when the design was configured with a slot width of 4 cm, reel speed of 50 rpm and reel kinematic index of 1.6. The prototype harvester with a 1 m working width produced the work rate of 0.18 ha h-1 and exhibited acceptable working quality. The main conclusion is that the modified stripper harvester can work in unevenness ground where other machines cannot operate.

  19. Design of a new terminal gas stripper system

    International Nuclear Information System (INIS)

    Alvarez, Daniela E.; Amodei, Aldo J.; Bonino, Adrian G.; Bustos, Gustavo R.; Giannico, Matias A.; Serdeiro, Guillermo A.; Pomar, Cayetano

    2002-01-01

    A new terminal gas stripper, for the electrostatic FN tandem accelerator of the AMS system at the Nuclear Regulatory Authority in Argentina, is being designed at present. Most of the vacuum, electrical and electronic components are already available. The remote control of the system is being developed at LABI (Eng. Faculty, Buenos Aires University, Argentina). In order to construct the vacuum chamber, a collaboration with the LNLS (Campinas Univ, Sao Paulo, Brazil) is under consideration. The status of the project is presented. (author)

  20. Beam foil interaction studies for the future stripper of Ganil

    International Nuclear Information System (INIS)

    Baron, E.; Ricaud, C.

    1988-01-01

    The GANIL 3 - cyclotron accelerator complex is to be upgraded in 1989 by increasing the beam energy at the stripper. In view of this modification, the effect of carbon stripper foils of various thicknesses (from 50 to 250 μg/cm 2 ) on the energy spread of Ar, Kr, Xe and Ta beams was measured using the analysing section of the 270 0 spectrometer. Energies ranging from 3.2 to 6.5 MeV/A (i.e corresponding to the future energy range) were used, and intensities of several hundreds of electrical nanoamperes were concentrated over a few mm 2 spot. Unusually large values of the additional energy spread are reported. In addition, charge state distributions of the 6.48 MeV/A Xe and 4.81 MeV/A Ta beams were measured as a function of the carbon thickness, in order to be able to choose how close to the equilibrium thickness the stripper should be, while keeping the energy spread of the outgoing beams within reasonable limits

  1. Simulation studies of gas and plasma-based charge strippers

    Energy Technology Data Exchange (ETDEWEB)

    Haas, Oliver Sebastian [Institut fuer Theorie Elektromagnetischer Felder, Technische Univ. Darmstadt (Germany); Boine-Frankenheim, Oliver [Institut fuer Theorie Elektromagnetischer Felder, Technische Univ. Darmstadt (Germany); GSI Helmholtz Centre for Heavy Ion Research, Darmstadt (Germany)

    2016-07-01

    Charge stripping of heavy ion beams at high intensities is a major challenge in current and future facilities with high intensity heavy ion beams. Conventional stripping techniques are limited in their applicability, e.g. solid carbon foils suffer from short lifetimes at high intensities and gas strippers usually achieve only low charge states. One possible alternative is the use of a plasma as a stripping medium. The presented work focuses on theoretical studies of the interaction of an heavy ion beam with a plasma and accompanying effects in possible charge strippers. The main interest in the presented studies is the final charge state distribution of the ion beam. Different models for solving the corresponding rate equations were developed, taking into account ionization, recombination, energy loss and straggling processes. Sophisticated models, e.g. for ionization cross sections, as well as limits and applicability of simplified models are discussed. Quantitative results are presented in form an overview of the charge state distributions of different - conventional and novel - charge stripping media. Furthermore comparisons are done with charge state distributions of available experimental data. Typical practically relevant target conditions are discussed as well as deterioration of beam quality.

  2. Techno-Economic Analysis of a Secondary Air Stripper Process

    Energy Technology Data Exchange (ETDEWEB)

    Heberle, J.R. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States); Nikolic, Heather [Center for Applied Energy Research, University of Kentucky, Lexington, KY (United States); Thompson, Jesse [Center for Applied Energy Research, University of Kentucky, Lexington, KY (United States); Liu, Kunlei [Center for Applied Energy Research, University of Kentucky, Lexington, KY (United States); Pinkerton, Lora L. [WorleyParsons, Reading, PA (United States); Brubaker, David [WorleyParsons, Reading, PA (United States); Simpson, James C. [WorleyParsons, Reading, PA (United States); Wu, Song [Mitsubishi Hitachi Power Systems America, Inc, Basking Ridge, NJ (United States); Bhown, Abhoyjit S. [Electric Power Research Inst. (EPRI), Palo Alto, CA (United States)

    2017-08-22

    We present results of an initial techno-economic assessment on a post-combustion CO2 capture process developed by the Center for Applied Energy Research (CAER) at the University of Kentucky using Mitsubishi Hitachi Power Systems’ H3-1 aqueous amine solvent. The analysis is based on data collected at a 0.7 MWe pilot unit combined with laboratory data and process simulations. The process adds a secondary air stripper to a conventional solvent process, which increases the cyclic loading of the solvent in two ways. First, air strips additional CO2 from the solvent downstream of the conventional steam-heated thermal stripper. This extra stripping of CO2 reduces the lean loading entering the absorber. Second, the CO2-enriched air is then sent to the boiler for use as secondary air. This recycling of CO2 results in a higher concentration of CO2 in the flue gas sent to the absorber, and hence a higher rich loading of the solvent exiting the absorber. A process model was incorporated into a full-scale supercritical pulverized coal power plant model to determine the plant performance and heat and mass balances. The performance and heat and mass balance data were used to size equipment and develop cost estimates for capital and operating costs. Lifecycle costs were considered through a levelized cost of electricity (LCOE) assessment based on the capital cost estimate and modeled performance. The results of the simulations show that the CAER process yields a regeneration energy of 3.12 GJ/t CO2, a $53.05/t CO2 capture cost, and LCOE of $174.59/MWh. This compares to the U.S. Department of Energy’s projected costs (Case 10) of regeneration energy of 3.58 GJ/t CO2 , a $61.31/t CO2 capture cost, and LCOE of $189.59/MWh. For H3-1, the CAER process results in a regeneration energy of 2.62 GJ/tCO2 with a stripper pressure of 5.2 bar, a capture cost of $46.93/t CO2, and an LCOE of $164.33/MWh.

  3. Carbon stripper foils held in place with carbon fibers

    International Nuclear Information System (INIS)

    Jolivet, Connie S.; Miller, Shawn A.; Stoner, John O.; Ladd, Peter

    2008-01-01

    The Spallation Neutron Source (SNS) currently under construction at Oak Ridge National Laboratory, Oak Ridge, Tennessee, is planned to initially utilize carbon stripper foils having areal densities approximately 260 μg/cm 2 . The projected design requires that each foil be supported by only one fixed edge. For stability of the foil, additional support is to be provided by carbon fibers. The feasibility of manufacturing and shipping such mounted carbon foils produced by arc evaporation was studied using two prototypes. Production of the foils is described. Fibers were chosen for satisfactory mechanical strength consistent with minimal interference with the SNS beam. Mounting of the fibers, and packaging of the assemblies for shipping are described. Ten completed assemblies were shipped to SNS for further testing. Preliminary evaluation of the survivability of the foils in the SNS foil changer is described

  4. Fabrication of versatile cladding light strippers and fiber end-caps with CO2 laser radiation

    Science.gov (United States)

    Steinke, M.; Theeg, T.; Wysmolek, M.; Ottenhues, C.; Pulzer, T.; Neumann, J.; Kracht, D.

    2018-02-01

    We report on novel fabrication schemes of versatile cladding light strippers and end-caps via CO2 laser radiation. We integrated cladding light strippers in SMA-like connectors for reliable and stable fiber-coupling of high-power laser diodes. Moreover, the application of cladding light strippers in typical fiber geometries for high-power fiber lasers was evaluated. In addition, we also developed processes to fuse end-caps to fiber end faces via CO2 laser radiation and inscribe the fibers with cladding light strippers near the end-cap. Corresponding results indicate the great potential of such devices as a monolithic and low-cost alternative to SMA connectors.

  5. Cooling tower calculations

    International Nuclear Information System (INIS)

    Simonkova, J.

    1988-01-01

    The problems are summed up of the dynamic calculation of cooling towers with forced and natural air draft. The quantities and relations are given characterizing the simultaneous exchange of momentum, heat and mass in evaporative water cooling by atmospheric air in the packings of cooling towers. The method of solution is clarified in the calculation of evaporation criteria and thermal characteristics of countercurrent and cross current cooling systems. The procedure is demonstrated of the calculation of cooling towers, and correction curves and the effect assessed of the operating mode at constant air number or constant outlet air volume flow on their course in ventilator cooling towers. In cooling towers with the natural air draft the flow unevenness is assessed of water and air relative to its effect on the resulting cooling efficiency of the towers. The calculation is demonstrated of thermal and resistance response curves and cooling curves of hydraulically unevenly loaded towers owing to the water flow rate parameter graded radially by 20% along the cross-section of the packing. Flow rate unevenness of air due to wind impact on the outlet air flow from the tower significantly affects the temperatures of cooled water in natural air draft cooling towers of a design with lower demands on aerodynamics, as early as at wind velocity of 2 m.s -1 as was demonstrated on a concrete example. (author). 11 figs., 10 refs

  6. Confusion at the Tower

    Science.gov (United States)

    Li, Loretta F.

    2014-01-01

    This study will explore the omission of the Tower of Babel narrative from middle and secondary school world history, world studies, and world geography textbooks and will consider what might be learned from inclusion of the story in the curriculum. A total of 17 textbooks are analyzed. The Tower of Babel narrative is examined within the context of…

  7. Wind tower service lift

    Science.gov (United States)

    Oliphant, David; Quilter, Jared; Andersen, Todd; Conroy, Thomas

    2011-09-13

    An apparatus used for maintaining a wind tower structure wherein the wind tower structure may have a plurality of legs and may be configured to support a wind turbine above the ground in a better position to interface with winds. The lift structure may be configured for carrying objects and have a guide system and drive system for mechanically communicating with a primary cable, rail or other first elongate member attached to the wind tower structure. The drive system and guide system may transmit forces that move the lift relative to the cable and thereby relative to the wind tower structure. A control interface may be included for controlling the amount and direction of the power into the guide system and drive system thereby causing the guide system and drive system to move the lift relative to said first elongate member such that said lift moves relative to said wind tower structure.

  8. Cooling tower waste reduction

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, S.J.; Celeste, J.; Chine, R.; Scott, C.

    1998-05-01

    At Lawrence Livermore National Laboratory (LLNL), the two main cooling tower systems (central and northwest) were upgraded during the summer of 1997 to reduce the generation of hazardous waste. In 1996, these two tower systems generated approximately 135,400 lbs (61,400 kg) of hazardous sludge, which is more than 90 percent of the hazardous waste for the site annually. At both, wet decks (cascade reservoirs) were covered to block sunlight. Covering the cascade reservoirs reduced the amount of chemical conditioners (e.g. algaecide and biocide), required and in turn the amount of waste generated was reduced. Additionally, at the northwest cooling tower system, a sand filtration system was installed to allow cyclical filtering and backflushing, and new pumps, piping, and spray nozzles were installed to increase agitation. the appurtenance upgrade increased the efficiency of the cooling towers. The sand filtration system at the northwest cooling tower system enables operators to continuously maintain the cooling tower water quality without taking the towers out of service. Operational costs (including waste handling and disposal) and maintenance activities are compared for the cooling towers before and after upgrades. Additionally, the effectiveness of the sand filter system in conjunction with the wet deck covers (northwest cooling tower system), versus the cascade reservoir covers alone (south cooling tower south) is discussed. the overall expected return on investment is calculated to be in excess of 250 percent. this upgrade has been incorporated into the 1998 DOE complex-wide water conservation project being led by Sandia National Laboratory/Albuquerque.

  9. Drop Tower Physics

    Science.gov (United States)

    Dittrich, William A. Toby

    2014-10-01

    The drop towers of yesteryear were used to make lead shot for muskets, as described in The Physics Teacher1 in April 2012. However, modern drop towers are essentially elevators designed so that the cable can "break" on demand, creating an environment with microgravity for a short period of time, currently up to nine seconds at the drop tower in Bremen, Germany. Using these drop towers, one can briefly investigate various physical systems operating in this near zero-g environment. The resulting "Drop Tower Physics" is a new and exciting way to challenge students with a physical example that requires solid knowledge of many basic physics principles, and it forces them to practice the scientific method. The question is, "How would a simple toy, like a pendulum, behave when it is suddenly exposed to a zero-g environment?" The student must then postulate a particular behavior, test the hypothesis against physical principles, and if the hypothesis conforms to these chosen physical laws, the student can formulate a final conclusion. At that point having access to a drop tower is very convenient, in that the student can then experimentally test his or her conclusion. The purpose of this discussion is to explain the response of these physical systems ("toys") when the transition is made to a zero-g environment and to provide video demonstrations of this behavior to support in-class discussions of Drop Tower Physics.

  10. Development and preparation of thin, supported targets and stripper foils

    International Nuclear Information System (INIS)

    Aaron, W.S.; Petek, M.; Zevenbergen, L.A.; Gibson, J.R.

    1989-01-01

    Usually, it is desirable to prepare thin films that are self-supporting so that any extraneous support materials will not interfere with experimental measurements. However, films with very low areal densities, films other than metals or films covering large areas may require the use of a backing or support. Two classes of supported thin films are being developed by the Isotope Research Materials Laboratory (IRML). Electrodeposition of oxide thin films is a fairly common target preparation technique that is usually performed on backings such as thin metal foils or low atomic number materials like Be and to a lesser extent, C foils. Techniques have been developed by IRML that result in electrodeposition of oxide films up to 500 μg/cm 2 on carbon foils or aluminized mylar. Electrodeposition is a very attractive target fabrication method since it is very efficient in the usage of rare and/or valuable isotopes. The ability to prepare these films on carbon or mylar foils provides a target that has, in most applications, far less interference resulting from the backing. Thin films of carbon, aluminum, boron and titanium are being used as stripper foils in the generation of neutral (H - →H 0 ) particle beams with energies of 50 MeV or greater. Neutralizer foils as large as 25 cm x 25 cm have been prepared from Al and C in thicknesses ranging from 5 to 12 μg/cm 2 that are mounted on thin nickel grids with a transmittance of approximately 90%. Significantly larger foils are currently under development. (orig.)

  11. Stripper, shut-in and orphan wells in joint operations

    International Nuclear Information System (INIS)

    Nixon, R.

    1999-01-01

    Low productivity wells, stripper wells, can be an excellent source of income to independent operators or small companies, but a serious financial burden for larger companies. Shut-in wells, for most companies, are either waiting on a market and production facilities, or represent deferred abandonment liabilities. Orphan wells also reflect financial distress. The firm, Cord Oil and Gas Management Ltd., was formed in 1986 to specifically assist oil and gas companies, sophisticated investors and financial institutions with the management, enhancement and disposition of non-core or low productivity assets. This type of production, depending on the number of wells and cumulative production, can be the life blood of a small organization or a serious drain on the administrative personnel and financial resources of larger organizations. Philosophically, industry and/or government needs to manage the eventuality of abandonments by establishing financial criteria. Some suggestions for industry include: (1) establish provisions within joint operating agreements to set aside an abandonment and environmental cleanup fund; (2) minimize the inventory of abandonment candidates by an ongoing program of reclamation; (3) offset abandonment costs with salvage value of tangible equipment under AFE approval; and (4) voluntarily restrict transfer abandonment liabilities with producing assets on a selective basis. Some suggestions for governments include: (1) fund the orphan well by a deposit for every well drilled; (2) restrict the transfer of liabilities for abandoned and inactive wells by ensuring that the transferee is financially capable; and (3) access the chain of title to ensure non-operators remain responsible for the proportionate shares of abandonment and cleanup costs

  12. Potentiality of the composite fulleren based carbon films as the stripper foils for tandem accelerators

    CERN Document Server

    Vasin, A V; Rusavsky, A V; Totsky, Y I; Vishnevski, I N

    2001-01-01

    The problem of the radiation resistance of the carbon stripper foils is considered. The short review of the experimental data available in literature and original experimental results of the are presented. In the paper discussed is the possibility of composite fulleren based carbon films to be used for preparation of the stripper foils. Some technological methods for preparation of composite fulleren based carbon films are proposed. Raman scattering and atom force microscopy were used for investigation of the fulleren and composite films deposited by evaporation of the C sub 6 sub 0 fulleren powder.

  13. Integrated chemical/biological treatment of paint stripper mixed waste: Metals toxicity and separation

    International Nuclear Information System (INIS)

    Vanderberg-Twary, L.; Grumbine, R.K.; Foreman, T.; Hanners, J.L.; Brainard, J.R.; Sauer, N.N.; Unkefer, P.J.

    1995-01-01

    The DOE complex has generated vast quantities of complex heterogeneous mixed wastes. Paint stripper waste (PSW) is a complex waste that arose from decontamination and decommissioning activities. It contains paint stripper, cheesecloth, cellulose-based paints with Pb and Cr, and suspect Pu. Los Alamos National Laboratory has 150--200 barrels of PSW and other national laboratories such as Rocky Flats Plant have many more barrels of heterogeneous waste. Few technologies exist that can treat this complex waste. Our approach to solving this problem is the integration of two established technologies: biodegradation and metals chelation

  14. Performance characteristics of counter flow wet cooling towers

    International Nuclear Information System (INIS)

    Khan, Jameel-Ur-Rehman; Yaqub, M.; Zubair, Syed M.

    2003-01-01

    Cooling towers are one of the biggest heat and mass transfer devices that are in widespread use. In this paper, we use a detailed model of counter flow wet cooling towers in investigating the performance characteristics. The validity of the model is checked by experimental data reported in the literature. The thermal performance of the cooling towers is clearly explained in terms of varying air and water temperatures, as well as the driving potential for convection and evaporation heat transfer, along the height of the tower. The relative contribution of each mode of heat transfer rate to the total heat transfer rate in the cooling tower is established. It is demonstrated with an example problem that the predominant mode of heat transfer is evaporation. For example, evaporation contributes about 62.5% of the total rate of heat transfer at the bottom of the tower and almost 90% at the top of the tower. The variation of air and water temperatures along the height of the tower (process line) is explained on psychometric charts

  15. Ejection Tower Lab

    Data.gov (United States)

    Federal Laboratory Consortium — The Ejection Tower Facility's mission is to test and evaluate new ejection seat technology being researched and developed for future defense forces. The captive and...

  16. Experimental study of swirl flow patterns in Gas Conditioning Tower at various entry conditions

    DEFF Research Database (Denmark)

    Jinov, Andrei A.; Larsen, Poul Scheel

    1999-01-01

    In a gas conditioning tower hot flue gas with relatively high dust loads is cooled by injecting water spray near the top. For satisfactory operation wet particles should be kept off walls and all water should have evaporated to yield a uniformly cooled flow before it reaches the bottom of the tower...

  17. Tracking cotton fiber quality and foreign matter through a stripper harvester

    Science.gov (United States)

    The main objective of this project was to track cotton fiber quality and foreign matter content throughout the harvesting units and conveying/cleaning systems on a brush-roll stripper harvester. Seed cotton samples were collected at six locations in 2011 and five in 2012 including: 1) hand-picked fr...

  18. NONPROCESS SOLVENT USE IN THE FURNITURE REFINISHING AND REPAIR INDUSTRY: EVALUATION OF ALTERNATIVE CHEMICAL STRIPPERS

    Science.gov (United States)

    The report gives results of an evaluation of the feasibility of using alternatives to high volatile organic compound/hazardous air pollutant (VOC/HAP) solvent-based, chemical strippers that are currently used in the furniture repair and refinishing industry to remove both traditi...

  19. Liquid-film stripper for high-intensity heavy-ion beams

    International Nuclear Information System (INIS)

    Leemann, B.T.; Merrill, P.; Syversrud, H.K.; Wada, R.; Yourd, R.B.

    1981-03-01

    Electron strippers are widely used in heavy ion accelerators such as tandem Van de Graaff generators and heavy ion linacs. The SuperHILAC at Lawrence Berkeley Laboratory, employs a fluorocarbon oil vapor stripper at 113 keV/A for its high intensity injector ABEL, while after acceleration to 1.199 MeV/A a 35 μg/cm 2 carbon foil stripper is used. At present, the lifetime of these foils is about 1 hour for an 40 Ar beam of approx. 1 μA average particle current. With higher intensity high mass (100 less than or equal to A less than or equal to 238) beams available from ABEL injector the lifetime is expected to drop drastically and might be as low as one minute. A different approach to solve the stripper foil lifetime problem uses a thin free standing oil film spun from the edge of a sharp-edged rotating disc touching the surface of an oil reservoir. Areas of about 10 cm 2 with areal densities down to 20 μg/cm 2 have been reported. The work described here is based on the same concept, and produces a constantly regenerated, stable, free standing oil film of appropriate thickness for use at the SuperHILAC

  20. Beam dynamics studies in the driver LINAC pre-stripper section of ...

    Indian Academy of Sciences (India)

    This section is designed to accept and accelerate two charge states (28 and 29) of uranium beam from an ECR ion source. The pre-stripper section must be designed to minimize the beam emittance distortion of this two-charge-state beam. In particular, the inter-cryostat spaces must be minimized and beam parameters ...

  1. A foil stripper and terminal steering assembly for an FN tandem

    International Nuclear Information System (INIS)

    Weitkamp, W.G.

    1989-01-01

    The authors report how they recently installed a new foil stripper mechanism and steerer assembly in their FN tandem terminal. The project had the following goals: To significantly increase the number of foils in the tandem. The authors formerly had only a 38 foil capacity. Now that the new superconducting booster is running, demand for foils has increased drastically. To add horizontal steering plates to the vertical steering plates in the terminal. With conventional HVEC inclined field beam tubes, the position of the beam at the exit of the tandem is sensitive to the variation in value of the column resistors. Minor beam tube misalignments can also cause the beam to come out displaced horizontally by an annoying amount. To retain the gas stripper tube. The authors occasionally find it convenient to use gas stripping for low energy heavy ion beams and for ions for which the foil consumption rate is excessive. To electrically insulate all terminal components so the terminal ripple remover will continue to operate. The terminal ripple remover, which is designed to reduce beam energy fluctuations, places a rapidly varying 2-9 kV bias on the stripper foil or stripper gas canal in response to an energy correction signal derived from the image slits. The energy correction signal is transmitted optically to the terminal

  2. Safety evaluation of the ITP filter/stripper test runs and quiet time runs using simulant solution. Revision 3

    International Nuclear Information System (INIS)

    Gupta, M.K.

    1994-06-01

    The purpose is to provide the technical bases for the evaluation of Unreviewed Safety Question for the In-Tank Precipitation (ITP) Filter/Stripper Test Runs (Ref. 7) and Quiet Time Runs Program (described in Section 3.6). The Filter/Stripper Test Runs and Quiet Time Runs program involves a 12,000 gallon feed tank containing an agitator, a 4,000 gallon flush tank, a variable speed pump, associated piping and controls, and equipment within both the Filter and the Stripper Building

  3. Lower parts of Temelin nuclear power plant cooling towers

    International Nuclear Information System (INIS)

    Sebek, J.

    1988-01-01

    The progress of work is described in detail on the foundations and lower parts of the cooling towers of the Temelin nuclear power plant. The cooling tower is placed on a reinforced concrete footing of a circular layout. Support pillars are erected on the reinforced concrete continuous footing. They consists of oblique shell stanchions. Inside, the footing joins up to monolithic wall and slab structures of the cooling tower tub. The tub bottom forms a foundation plate supporting prefab structures of the cooling tower inner structural systems. The framed support of the chimney shell consists of 56 pairs of prefabricated oblique stanchions. Following their erection into the final position and anchoring in the continuous footing, the concreting of the casing can start of the reinforced conrete chimney. (Z.M.). 3 figs

  4. Cooling towers: a bibliography

    International Nuclear Information System (INIS)

    Whitson, M.O.

    1981-02-01

    This bibliography cites 300 selected references containing information on various aspects of large cooling tower technology, including design, construction, operation, performance, economics, and environmental effects. The towers considered include natural-draft and mechanical-draft types employing wet, dry, or combination wet-dry cooling. A few references deal with alternative cooling methods, principally ponds or spray canals. The citations were compiled for the DOE Energy Information Data Base (EDB) covering the period January to December 1980. The references are to reports from the Department of Energy and its contractors, reports from other government or private organizations, and journal articles, books, conference papers, and monographs from US originators

  5. Talking Towers, Making Withs.

    Science.gov (United States)

    Lemke, J. L.

    The notion of a linguistic "register" is useful in posing questions about how the ways language is used differ from one kind of human activity to another. This paper analyzes a videotaped segment of male grade 4/5 students (n=3) who are talking as they work to build a tower from plastic drinking straws and pins. Discussion of the…

  6. Cell Towers and Songbirds

    Science.gov (United States)

    Klosterman, Michelle; Mesa, Jennifer; Milton, Katie

    2009-01-01

    This article describes how our common addiction to cell phones was used to launch a discussion about their use, impacts on the environment, and connections to issues of civic concern. By encouraging middle school science students to adopt the perspectives of special-interest groups debating communication tower restrictions designed to protect…

  7. TacTower

    DEFF Research Database (Denmark)

    Rasmussen, Majken Kirkegaard; Jürgensen, Christine

    2009-01-01

    Learning from the multiplayer interaction in sports, we describe our project TacTower; a flexible system for professional elite handball players to train game perception and kinesthetic em- pathy. The design is founded in ideas of Collective Interaction and qualities that is inherent in sport...... and is based on consid- erations about paralanguage, kinesthetic emphatic interaction, physical positioning of players and collaborative interaction....

  8. Effect of thickness of foil strippers in transmission of beams through 15 UD pelletron accelerator at IUAC

    International Nuclear Information System (INIS)

    Ojha, S.; Pankaj Kumar; Gargari, S.; Joshi, R.; Abhilash; Kabiraj, D.; Chopra, S.

    2009-01-01

    15 UD Pelletron accelerator at IUAC, New Delhi is equipped with a foil stripper and a gas stripper at high voltage terminal. Besides these, we have foil stripper assemblies at High Energy Dead Section (HEDS) of Pelletron and after analyser magnet. Incoming negative ion looses electrons when they pass through the strippers at terminal and becomes positively charged. The next foil stripper at HEDS increases the positive charge state of ion by removing more electrons which helps in delivering beams at higher energy. Typical thickness of carbon foils loaded in the foil stripper assembly in the terminal is around 4 microgram per square centimetre (4 μg/cm 2 ). Thicker foils were installed in the terminal assembly to study the effect of thickness of foil on charge state distribution and transmission of ion beams. Charge state distribution of ions produced out of molecular beam was also studied. In this paper we present and discuss the results and observations with thicker foils on ion as well as molecular beams. (author)

  9. Solar tower enhanced natural draft dry cooling tower

    Science.gov (United States)

    Yang, Huiqiang; Xu, Yan; Acosta-Iborra, Alberto; Santana, Domingo

    2017-06-01

    Concentrating Solar Power (CSP) plants are located in desert areas where the Direct Normal Irradiance (DNI) value is very high. Since water resource is scarcely available, mechanical draft cooing technology is commonly used, with power consumption of mechanical fans being approximately 2% of the total power generated. Today, there is only one solar power plant (Khi Solar One in South Africa) uses a condenser installed in a Natural Draft Cooling (NDC) tower that avoids the windage loss of water occurring in wet cooling towers. Although, Khi Solar One is a cavity receiver power tower, the receivers can be hung onto the NDC tower. This paper looks at a novel integration of a NDC tower into an external molten salt receiver of a solar power plant, which is one of a largest commercial molten salt tower in China, with 100MWe power capacity. In this configuration study, the NDC tower surrounds the concrete tower of the receiver concentrically. In this way, the receiver concrete tower is the central support of the NDC tower, which consists of cable networks that are fixed to the concrete tower and suspended at a certain height over the floor. The cable networks support the shell of the NDC tower. To perform a preliminary analysis of the behavior of this novel configuration, two cases of numerical simulation in three dimensional (3D) models have been solved using the commercial Computational Fluid Dynamics (CFD) code, ANSYS Fluent 6.3. The results show that the integration of the NDC tower into an external central receiver tower is feasible. Additionally, the total heat transfer rate is not reduced but slightly increases when the molten salt receiver is in operation because of the additional natural draft induced by the high temperature of the receiver.

  10. Good Towers of Function Fields

    DEFF Research Database (Denmark)

    Bassa, Alp; Beelen, Peter; Nguyen, Nhut

    2014-01-01

    In this paper, we will give an overview of known and new techniques on how one can obtain explicit equations for candidates of good towers of function fields. The techniques are founded in modular theory (both the classical modular theory and the Drinfeld modular theory). In the classical modular...... setup, optimal towers can be obtained, while in the Drinfeld modular setup, good towers over any non-prime field may be found. We illustrate the theory with several examples, thus explaining some known towers as well as giving new examples of good explicitly defined towers of function fields....

  11. Intense heavy ion beam-induced effects in carbon-based stripper foils

    Energy Technology Data Exchange (ETDEWEB)

    Kupka, Katharina

    2016-08-15

    Amorphous carbon or carbon-based stripper foils are commonly applied in accelerator technology for electron stripping of ions. At the planned facility for antiproton and ion research (FAIR) at the Helmholtzzentrum fuer Schwerionenforschung (GSI), Darmstadt, thin carbon stripper foils provide an option for directly delivering ions of intermediate charge states to the heavy ion synchrotron, SIS 18, in order to mitigate space charge limitations during high-intensity operation. In case of desired high end-energies in the synchrotron, a second stripping process by a thicker carbon foil provides ions of higher charge states for injection into the SIS18. High beam intensities and a pulsed beam structure as foreseen at FAIR pose new challenges to the stripper foils which experience enhanced degradation by radiation damage, thermal effects, and stress waves. In order to ensure reliable accelerator operation, radiation-hard stripper foils are required. This thesis aims to a better understanding of processes leading to degradation of carbon-based thin foils. Special focus is placed on ion-beam induced structure and physical property changes and on the influence of different beam parameters. Irradiation experiments were performed at the M3-beamline of the universal linear accelerator (UNILAC) at GSI, using swift heavy ion beams with different pulse lengths and repetition rates. Tested carbon foils were standard amorphous carbon stripper foils produced by the GSI target laboratory, as well as commercial amorphous and diamond-like carbon foils and buckypaper foils. Microstructural changes were investigated with various methods such as optical microscopy, scanning electron microscopy (SEM), profilometry and chromatic aberration measurements. For the investigation of structural changes X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, high resolution transmission electron microscopy (HRTEM), in-situ Fourier-transform infrared spectroscopy (FTIR) and small angle X

  12. Intense heavy ion beam-induced effects in carbon-based stripper foils

    International Nuclear Information System (INIS)

    Kupka, Katharina

    2016-08-01

    Amorphous carbon or carbon-based stripper foils are commonly applied in accelerator technology for electron stripping of ions. At the planned facility for antiproton and ion research (FAIR) at the Helmholtzzentrum fuer Schwerionenforschung (GSI), Darmstadt, thin carbon stripper foils provide an option for directly delivering ions of intermediate charge states to the heavy ion synchrotron, SIS 18, in order to mitigate space charge limitations during high-intensity operation. In case of desired high end-energies in the synchrotron, a second stripping process by a thicker carbon foil provides ions of higher charge states for injection into the SIS18. High beam intensities and a pulsed beam structure as foreseen at FAIR pose new challenges to the stripper foils which experience enhanced degradation by radiation damage, thermal effects, and stress waves. In order to ensure reliable accelerator operation, radiation-hard stripper foils are required. This thesis aims to a better understanding of processes leading to degradation of carbon-based thin foils. Special focus is placed on ion-beam induced structure and physical property changes and on the influence of different beam parameters. Irradiation experiments were performed at the M3-beamline of the universal linear accelerator (UNILAC) at GSI, using swift heavy ion beams with different pulse lengths and repetition rates. Tested carbon foils were standard amorphous carbon stripper foils produced by the GSI target laboratory, as well as commercial amorphous and diamond-like carbon foils and buckypaper foils. Microstructural changes were investigated with various methods such as optical microscopy, scanning electron microscopy (SEM), profilometry and chromatic aberration measurements. For the investigation of structural changes X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, high resolution transmission electron microscopy (HRTEM), in-situ Fourier-transform infrared spectroscopy (FTIR) and small angle X

  13. Intense heavy ion beam-induced temperature effects in carbon-based stripper foils

    International Nuclear Information System (INIS)

    Kupka, K.; Tomut, M.; Simon, P.; Hubert, C.; Romanenko, A.; Lommel, B.; Trautmann, C.

    2015-01-01

    At the future FAIR facility, reliably working solid carbon stripper foils are desired for providing intermediate charge states to SIS18. With the expected high beam intensities, the foils experience enhanced degradation and limited lifetime due to severe radiation damage, stress waves, and thermal effects. This work presents systematic measurements of the temperature of different carbon-based stripper foils (amorphous, diamond-like, and carbon-nanotube based) exposed to 4.8 MeV/u U, Bi, and Au beams of different pulse intensities. Thermal and spectroscopic analyses were performed by means of infrared thermography and Fourier transform infrared spectroscopy. The resulting temperature depends on the foil thickness and strongly increases with increasing pulse intensity and repetition rate. (author)

  14. Surface treatment of glass substrates for the preparation of long-lived carbon stripper foils

    International Nuclear Information System (INIS)

    Takeuchi, Suehiro; Takekoshi, Eiko

    1981-02-01

    Glass substrates having uniformly distributed microscopic grains on the surfaces are useful to make long-lived carbon stripper foils for heavy ions. A method of surface treatment of glass substrates to form the surface structure is described. This method consists of precipitation of glass components, such as soda, onto the surfaces in a hot and humid atmosphere and a fogging treatment of forming microscopic grains of the precipitated substances. Some results of studies on the treatment conditions are also presented. (author)

  15. LOW COST METHODOLOGIES TO ANALYZE AND CORRECT ABNORMAL PRODUCTION DECLINE IN STRIPPER GAS WELLS

    International Nuclear Information System (INIS)

    Jerry James; Gene Huck; Tim Knobloch

    2001-01-01

    A study group of 376 Clinton Sand wells in Ohio provided data to determine the historic frequency of the problem of abnormal production declines in stripper gas wells and the causes of the abnormal production decline. Analysis of the historic frequency of the problem indicates over 70% of the wells experienced abnormal production decline. The most frequently occurring causes of abnormal production declines were determined to be fluid accumulation (46%), gas gathering restrictions (24%), and mechanical failures (23%). Data collection forms and decision trees were developed to cost-effectively diagnose the abnormal production declines and suggest corrective action. The decision trees and data collection sheets were incorporated into a procedure guide to provide stripper gas well operators with a methodology to analyze and correct abnormal production declines. The systematic methodologies and techniques developed should increase the efficiency of problem well assessment and implementation of solutions for stripper gas wells. This eight quarterly technical progress report provides a summary of the deliverables completed to date, including the results of the remediations, the procedure guide, and the technology transfer. Due to the successful results of the study to date and the efficiency of the methodology development, two to three additional wells will be selected for remediation for inclusion into the study. The results of the additional remediations will be included in the final report

  16. Field Loss Estimation Of A Developed Rice Stripper Harvester In Nigeria

    Directory of Open Access Journals (Sweden)

    2016-11-01

    Full Text Available Reduction in post harvest losses must inevitably start with minimizing losses during harvesting. So far, grain stripping harvester is a technology which is being developed and is becoming effective for rice and wheat harvesting. Grain losses in stripping harvester occur at the gathering/stripping operation which are shattering, stubble and lodging losses. The harvest loss estimation of rice harvesting with a self propelled grain stripper developed in Nigeria was carried out. At best machine settings, determined were critical operating parameters to obtain total minimum harvest loss estimation which was 13.5% of the total yield while the manual harvesting loss was 20.3% under the same condition. The machine setting at this combination was rotor height of 270.0 mm, peripheral rotor speed of 670.0 rpm and forward speed was 3.0 km/h which gave shattering loss as 5.5%, stubble loss was 4.9% and lodging loss was 3.1% of the total yield. It was found that planting pure seed variety will reduce stripper header losses at harvest because it will result in uniform crop height at maturity which was one of the design factors that affected the harvester performance on the field. Keywords:Estimation, field loss, stripper, rice, developed

  17. TacTowers

    DEFF Research Database (Denmark)

    Ludvigsen, Martin; Fogtmann, Maiken Hillerup; Grønbæk, Kaj

    2010-01-01

    The interactive training equipment, TacTower, is aimed at supporting multiple elite athletes, such as handball players in training their micro-tactical skills in close-contact situations. It focuses on psychomotor abilities and trains the skills involved in reading the opponents’ actions and anti...... for the elite athletic community, as this domain holds interesting challenges while also inspiring relevant, new forms of interaction design for other domains....

  18. Bottom production

    Energy Technology Data Exchange (ETDEWEB)

    Baines, J.; Baranov, S.P.; Bartalini, P.; Bay, A.; Bouhova, E.; Cacciari, M.; Caner, A.; Coadou, Y.; Corti, G.; Damet, J.; Dell-Orso, R.; De Mello Neto, J.R.T.; Domenech, J.L.; Drollinger, V.; Eerola, P.; Ellis, N.; Epp, B.; Frixione, S.; Gadomski, S.; Gavrilenko, I.; Gennai, S.; George, S.; Ghete, V.M.; Guy, L.; Hasegawa, Y.; Iengo, P.; Jacholkowska, A.; Jones, R.; Kharchilava, A.; Kneringer, E.; Koppenburg, P.; Korsmo, H.; Kramer, M.; Labanca, N.; Lehto, M.; Maltoni, F.; Mangano, M.L.; Mele, S.; Nairz, A.M.; Nakada, T.; Nikitin, N.; Nisati, A.; Norrbin, E.; Palla, F.; Rizatdinova, F.; Robins, S.; Rousseau, D.; Sanchis-Lozano, M.A.; Shapiro, M.; Sherwood, P.; Smirnova, L.; Smizanska, M.; Starodumov, A.; Stepanov, N.; Vogt, R.

    2000-03-15

    In the context of the LHC experiments, the physics of bottom flavoured hadrons enters in different contexts. It can be used for QCD tests, it affects the possibilities of B decays studies, and it is an important source of background for several processes of interest. The physics of b production at hadron colliders has a rather long story, dating back to its first observation in the UA1 experiment. Subsequently, b production has been studied at the Tevatron. Besides the transverse momentum spectrum of a single b, it has also become possible, in recent time, to study correlations in the production characteristics of the b and the b. At the LHC new opportunities will be offered by the high statistics and the high energy reach. One expects to be able to study the transverse momentum spectrum at higher transverse momenta, and also to exploit the large statistics to perform more accurate studies of correlations.

  19. Bottom Production

    CERN Document Server

    Nason, P.; Schneider, O.; Tartarelli, G.F.; Vikas, P.; Baines, J.; Baranov, S.P.; Bartalini, P.; Bay, A.; Bouhova, E.; Cacciari, M.; Caner, A.; Coadou, Y.; Corti, G.; Damet, J.; Dell'Orso, R.; De Mello Neto, J.R.T.; Domenech, J.L.; Drollinger, V.; Eerola, P.; Ellis, N.; Epp, B.; Frixione, S.; Gadomski, S.; Gavrilenko, I.; Gennai, S.; George, S.; Ghete, V.M.; Guy, L.; Hasegawa, Y.; Iengo, P.; Jacholkowska, A.; Jones, R.; Kharchilava, A.; Kneringer, E.; Koppenburg, P.; Korsmo, H.; Kramer, M.; Labanca, N.; Lehto, M.; Maltoni, F.; Mangano, Michelangelo L.; Mele, S.; Nairz, A.M.; Nakada, T.; Nikitin, N.; Nisati, A.; Norrbin, E.; Palla, F.; Rizatdinova, F.; Robins, S.; Rousseau, D.; Sanchis-Lozano, M.A.; Shapiro, M.; Sherwood, P.; Smirnova, L.; Smizanska, M.; Starodumov, A.; Stepanov, N.; Vogt, R.

    2000-01-01

    We review the prospects for bottom production physics at the LHC. Members of the working group who has contributed to this document are: J. Baines, S.P. Baranov, P. Bartalini, A. Bay, E. Bouhova, M. Cacciari, A. Caner, Y. Coadou, G. Corti, J. Damet, R. Dell'Orso, J.R.T. De Mello Neto, J.L. Domenech, V. Drollinger, P. Eerola, N. Ellis, B. Epp, S. Frixione, S. Gadomski, I. Gavrilenko, S. Gennai, S. George, V.M. Ghete, L. Guy, Y. Hasegawa, P. Iengo, A. Jacholkowska, R. Jones, A. Kharchilava, E. Kneringer, P. Koppenburg, H. Korsmo, M. Kraemer, N. Labanca, M. Lehto, F. Maltoni, M.L. Mangano, S. Mele, A.M. Nairz, T. Nakada, N. Nikitin, A. Nisati, E. Norrbin, F. Palla, F. Rizatdinova, S. Robins, D. Rousseau, M.A. Sanchis-Lozano, M. Shapiro, P. Sherwood, L. Smirnova, M. Smizanska, A. Starodumov, N. Stepanov, R. Vogt

  20. Consortium for Petroleum & Natural Gas Stripper Wells PART 3 OF 3

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Joel [Pennsylvania State Univ., University Park, PA (United States)

    2011-12-01

    The United States has more oil and gas wells than any other country. As of December 31, 2004, there were more than half a million producing oil wells in the United States. That is more than three times the combined total for the next three leaders: China, Canada, and Russia. The Stripper Well Consortium (SWC) is a partnership that includes domestic oil and gas producers, service and supply companies, trade associations, academia, the Department of Energy’s Strategic Center for Natural Gas and Oil (SCNGO) at the National Energy Technology Laboratory (NETL), and the New York State Energy Research and Development Authority (NYSERDA). The Consortium was established in 2000. This report serves as a final technical report for the SWC activities conducted over the May 1, 2004 to December 1, 2011 timeframe. During this timeframe, the SWC worked with 173 members in 29 states and three international countries, to focus on the development of new technologies to benefit the U.S. stripper well industry. SWC worked with NETL to develop a nationwide request-for-proposal (RFP) process to solicit proposals from the U.S. stripper well industry to develop and/or deploy new technologies that would assist small producers in improving the production performance of their stripper well operations. SWC conducted eight rounds of funding. A total of 132 proposals were received. The proposals were compiled and distributed to an industrydriven SWC executive council and program sponsors for review. Applicants were required to make a formal technical presentation to the SWC membership, executive council, and program sponsors. After reviewing the proposals and listening to the presentations, the executive council made their funding recommendations to program sponsors. A total of 64 projects were selected for funding, of which 59 were fully completed. Penn State then worked with grant awardees to issue a subcontract for their approved work. SWC organized and hosted a total of 14 meetings

  1. Consortium for Petroleum & Natural Gas Stripper Wells PART 2 OF 3

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Joel [Pennsylvania State Univ., University Park, PA (United States)

    2011-12-01

    The United States has more oil and gas wells than any other country. As of December 31, 2004, there were more than half a million producing oil wells in the United States. That is more than three times the combined total for the next three leaders: China, Canada, and Russia. The Stripper Well Consortium (SWC) is a partnership that includes domestic oil and gas producers, service and supply companies, trade associations, academia, the Department of Energy’s Strategic Center for Natural Gas and Oil (SCNGO) at the National Energy Technology Laboratory (NETL), and the New York State Energy Research and Development Authority (NYSERDA). The Consortium was established in 2000. This report serves as a final technical report for the SWC activities conducted over the May 1, 2004 to December 1, 2011 timeframe. During this timeframe, the SWC worked with 173 members in 29 states and three international countries, to focus on the development of new technologies to benefit the U.S. stripper well industry. SWC worked with NETL to develop a nationwide request-for-proposal (RFP) process to solicit proposals from the U.S. stripper well industry to develop and/or deploy new technologies that would assist small producers in improving the production performance of their stripper well operations. SWC conducted eight rounds of funding. A total of 132 proposals were received. The proposals were compiled and distributed to an industrydriven SWC executive council and program sponsors for review. Applicants were required to make a formal technical presentation to the SWC membership, executive council, and program sponsors. After reviewing the proposals and listening to the presentations, the executive council made their funding recommendations to program sponsors. A total of 64 projects were selected for funding, of which 59 were fully completed. Penn State then worked with grant awardees to issue a subcontract for their approved work. SWC organized and hosted a total of 14 meetings

  2. All fiber cladding mode stripper with uniform heat distribution and high cladding light loss manufactured by CO2 laser ablation

    Science.gov (United States)

    Jebali, M. A.; Basso, E. T.

    2018-02-01

    Cladding mode strippers are primarily used at the end of a fiber laser cavity to remove high-power excess cladding light without inducing core loss and beam quality degradation. Conventional manufacturing methods of cladding mode strippers include acid etching, abrasive blasting or laser ablation. Manufacturing of cladding mode strippers using laser ablation consist of removing parts of the cladding by fused silica ablation with a controlled penetration and shape. We present and characterize an optimized cladding mode stripper design that increases the cladding light loss with a minimal device length and manufacturing time. This design reduces the localized heat generation by improving the heat distribution along the device. We demonstrate a cladding mode stripper written on a 400um fiber with cladding light loss of 20dB, with less than 0.02dB loss in the core and minimal heating of the fiber and coating. The manufacturing process of the designed component is fully automated and takes less than 3 minutes with a very high throughput yield.

  3. FLORIDA TOWER FOOTPRINT EXPERIMENTS

    Energy Technology Data Exchange (ETDEWEB)

    WATSON,T.B.; DIETZ, R.N.; WILKE, R.; HENDREY, G.; LEWIN, K.; NAGY, J.; LECLERC, M.

    2007-01-01

    The Florida Footprint experiments were a series of field programs in which perfluorocarbon tracers were released in different configurations centered on a flux tower to generate a data set that can be used to test transport and dispersion models. These models are used to determine the sources of the CO{sub 2} that cause the fluxes measured at eddy covariance towers. Experiments were conducted in a managed slash pine forest, 10 km northeast of Gainesville, Florida, in 2002, 2004, and 2006 and in atmospheric conditions that ranged from well mixed, to very stable, including the transition period between convective conditions at midday to stable conditions after sun set. There were a total of 15 experiments. The characteristics of the PFTs, details of sampling and analysis methods, quality control measures, and analytical statistics including confidence limits are presented. Details of the field programs including tracer release rates, tracer source configurations, and configuration of the samplers are discussed. The result of this experiment is a high quality, well documented tracer and meteorological data set that can be used to improve and validate canopy dispersion models.

  4. U^{28+}-intensity record applying a H_{2}-gas stripper cell

    Directory of Open Access Journals (Sweden)

    Winfried Barth

    2015-04-01

    Full Text Available To meet the Facility for Antiproton and Ion Research science requirements higher beam intensity has to be achieved in the present GSI-accelerator complex. For this an advanced upgrade program for the UNILAC is ongoing. Stripping is a key technology for all heavy ion accelerators. For this an extensive research and development program was carried out to optimize for high brilliance heavy ion operation. After upgrade of the supersonic N_{2}-gas jet (2007, implementation of high current foil stripping (2011 and preliminary investigation of H_{2}-gas jet operation (2012, recently (2014 a new H_{2}-gas cell using a pulsed gas regime synchronized with arrival of the beam pulse has been developed. An obviously enhanced stripper gas density as well as a simultaneously reduced gas load for the pumping system result in an increased stripping efficiency, while the beam emittance remains the same. A new record intensity (7.8 emA for ^{238}U^{28+} beams at 1.4  MeV/u has been achieved applying the pulsed high density H_{2} stripper target to a high intensity ^{238}U^{4+} beam from the VARIS ion source with a newly developed extraction system. The experimental results are presented in detail.

  5. Cooling towers principles and practice

    CERN Document Server

    Hill, G B; Osborn, Peter D

    1990-01-01

    Cooling Towers: Principles and Practice, Third Edition, aims to provide the reader with a better understanding of the theory and practice, so that installations are correctly designed and operated. As with all branches of engineering, new technology calls for a level of technical knowledge which becomes progressively higher; this new edition seeks to ensure that the principles and practice of cooling towers are set against a background of up-to-date technology. The book is organized into three sections. Section A on cooling tower practice covers topics such as the design and operation of c

  6. Evaluation Of Cooling Tower Degradation

    International Nuclear Information System (INIS)

    Djunaidi

    2001-01-01

    Cooling tower degradation has been evaluated for the last 10 years. Its heat transfer capacity has been decreasing after several years of operation due to aging. Evaluation is carried out by calculating the degradation rate, namely the annual increase of outlet temperatures of the cooling tower. Data was randomly taken daily at 15 MW reactor power. Data was taken after the reactor operation of ± 8 hours. Evaluation since 1990 shows that the degradation rate is nearly one degree per year. This degradation can be by minimized, replacement of damaged components, non-excessive operation and design modification of the cooling tower namely by extending the period of contract between water and air

  7. FROM THE PACKED TOWERS

    Directory of Open Access Journals (Sweden)

    Valderi D. Leite

    2013-01-01

    Full Text Available About 245 thousand tones of municipal solid w aste are collected daily in Brazil. Nearly 32 thousand tones of the collected amount are treated in sanitary landfill, which generates biogas and leachate as byproduct. The leachate resulting from sanitary landfill contains high concentration of carbonaceous and nitrogenized material. The crucial question is that the biodegradation of the carbonaceous material is difficult as long as the nitrogenized material is presen t in the form of ammoniacal nitrogen (NH 4 + , which compromises performance of biological tr eatment process. Therefore, a physical and chemical treatment of the leachate should be done before its biological treatment, especially for reduction of ammoniacal nitr ogen concentration and for propitiating the realization of application of biological treatment. The treatment of leachate requires specific consideration, which is not needed fo r other types of waste. In the specific case in this study, where ammoniacal nitrogen concentration was about 2,200 mgN L -1 and the BOD 5 /COD ratio was 0.3, the study of ammonia stripping process was performed. Ammonia stripping process was studied in pack ed towers of 35 L capacity each and the parameters investigated were pH, ratio of contact area/leach volume and the aeration time. One of the parameters that influenced most in efficiency of ammonia stripping process was pH of the leachate since it contributes in conversion of ammoniacal nitrogen from NH 4 + to NH 3 .

  8. 45-FOOT HIGH DROP TOWER

    Data.gov (United States)

    Federal Laboratory Consortium — The Drop Tower is used to simulate and measure the impact shocks that are exerted on parachute loads when they hit the ground. It is also used for HSL static lift to...

  9. The Millennium Tower in Magdeburg

    OpenAIRE

    Eike Grabert; Svetlana Seredenkina

    2004-01-01

    The Millenium Tower in Magdeburg, Germany, was built in 1999. It is possibly the biggest wooden tower of the world. The dissymetric «slanting» tower is 60 meters high, the foundation is 70 meters by 50 meters, and the size is 61000 cubic meters. The panelling is made of glass fabric. On the whole 5500 cubic meters of timber was used. On its 8030 square meters the tower houses a big exhibition about the history of mankind and scientific development.

  10. The Millennium Tower in Magdeburg

    Directory of Open Access Journals (Sweden)

    Eike Grabert

    2004-11-01

    Full Text Available The Millenium Tower in Magdeburg, Germany, was built in 1999. It is possibly the biggest wooden tower of the world. The dissymetric «slanting» tower is 60 meters high, the foundation is 70 meters by 50 meters, and the size is 61000 cubic meters. The panelling is made of glass fabric. On the whole 5500 cubic meters of timber was used. On its 8030 square meters the tower houses a big exhibition about the history of mankind and scientific development.

  11. Allegheny County Cell Tower Points

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — This dataset portrays cell tower locations as points in Allegheny County. The dataset is based on outbuilding codes in the Property Assessment Parcel Database used...

  12. The Design of Akhmat Tower

    Science.gov (United States)

    Beardsley, Sara; Stochetti, Alejandro; Cerone, Marc

    2018-03-01

    Akhmat Tower is a 435m supertall building designed by Adrian Smith + Gordon Gill Architecture. It is currently under construction in the city of Grozny, in the Chechen Republic, in the North Caucasus region of Russia. The design of the tower was done during a collaborative process by a multi-disciplinary architectural and engineering team, based primarily in the United States and Russia. During this process, the designers considered many factors including, most primarily, the cultural and historical context, the structural requirements given the high seismicity of the region, and the client's programmatic needs. The resulting crystalline-shaped tower is both an aesthetic statement and a performative architectural solution which will be a new landmark for Chechnya. "The Design of Akhmat Tower" describes in detail the design process including structural considerations, exterior wall design, building program, interior design, the tuned mass damper, and the use of building information modeling.

  13. Low-Z gas stripper as an alternative to carbon foils for the acceleration of high-power uranium beams

    Directory of Open Access Journals (Sweden)

    H. Okuno

    2011-03-01

    Full Text Available The RIKEN accelerator complex started feeding the next-generation exotic beam facility radioisotope beam factory (RIBF with heavy-ion beams from 2007 after the successful commissioning of RIBF at the end of 2006. Many improvements made from 2007 to 2010 were instrumental in increasing the intensity of various heavy-ion beams. However, the available beam intensity of very heavy ion beams, especially uranium beams, is far below our goal of 1  pμA (6×10^{12}  particles/s. In order to achieve this goal, upgrade programs are already in progress; the programs include the construction of a new 28-GHz superconducting electron cyclotron resonance ion source and a new injector linac. However, the most serious problem, that of a charge stripper for high-power uranium beams, still remains unsolved, despite extensive research and development work using large foils mounted on a rotating cylinder and a N_{2} gas stripper. A gas stripper is free from problems related to lifetime, though the equilibrium charge state in this stripper is considerably lower than that in a carbon foil, owing to the absence of the density effect. Nevertheless, the merits of gas strippers motivated us to develop a low-Z gas stripper to achieve a higher equilibrium charge state even in gases. We measured the electron-loss and electron-capture cross sections of uranium ions in He gas as a function of their charge state at 11, 14, and 15  MeV/nucleon. The equilibrium charge states extracted from the intersection of the lines of the two cross sections were promisingly higher than those in N_{2} gas by more than 10. Simple simulations of charge development along the stripper thickness were performed by assuming the measured cross sections. The simulation results show that about 1  mg/cm^{2} of He gas should be accumulated to achieve a charge state higher than that of N_{2} gas, notwithstanding the difficulty in accumulation of this helium amount owing to its fast

  14. The Physics of Shot Towers

    Science.gov (United States)

    Lipscombe, Trevor C.; Mungan, Carl E.

    2012-01-01

    In the late 18th and throughout the 19th century, lead shot for muskets was prepared by use of a shot tower. Molten lead was poured from the top of a tower and, during its fall, the drops became spherical under the action of surface tension. In this article, we ask and answer the question: "How does the size of the lead shot depend on the height…

  15. Tower Temperature and Humidity Sensors (TWR) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Cook, DR

    2010-02-01

    Three tall towers are installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility: a 60-meter triangular tower at the Southern Great Plains (SGP) Central Facility (CF), a 21-meter walkup scaffolding tower at the SGP Okmulgee forest site (E21), and a 40-meter triangular tower at the North Slope of Alaska (NSA) Barrow site. The towers are used for meteorological, radiological, and other measurements.

  16. SELECTION AND TREATMENT OF STRIPPER GAS WELLS FOR PRODUCTION ENHANCEMENT, MOCANE-LAVERNE FIELD, OKLAHOMA

    Energy Technology Data Exchange (ETDEWEB)

    Scott Reeves; Buckley Walsh

    2003-08-01

    In 1996, Advanced Resources International (ARI) began performing R&D targeted at enhancing production and reserves from natural gas fields. The impetus for the effort was a series of field R&D projects in the early-to-mid 1990's, in eastern coalbed methane and gas shales plays, where well remediation and production enhancement had been successfully demonstrated. As a first step in the R&D effort, an assessment was made of the potential for restimulation to provide meaningful reserve additions to the U.S. gas resource base, and what technologies were needed to do so. That work concluded that: (1) A significant resource base did exist via restimulation (multiples of Tcf). (2) The greatest opportunities existed in non-conventional plays where completion practices were (relatively) complex and technology advancement was rapid. (3) Accurate candidate selection is the greatest single factor that contributes to a successful restimulation program. With these findings, a field-oriented program targeted at tight sand formations was initiated to develop and demonstrate successful candidate recognition technology. In that program, which concluded in 2001, nine wells were restimulated in the Green River, Piceance and East Texas basins, which in total added 2.9 Bcf of reserves at an average cost of $0.26/Mcf. In addition, it was found that in complex and heterogeneous reservoirs (such as tight sand formations), candidate selection procedures should involve a combination of fundamental engineering and advanced pattern recognition approaches, and that simple statistical methods for identifying candidate wells are not effective. In mid-2000, the U.S. Department of Energy (DOE) awarded ARI an R&D contract to determine if the methods employed in that project could also be applied to stripper gas wells. In addition, the ability of those approaches to identify more general production enhancement opportunities (beyond only restimulation), such as via artificial lift and compression

  17. Development of solar tower observatories

    Science.gov (United States)

    Wolfschmidt, Gudrun

    Because the horizontal solar telescope, the Snow Telescope in Yerkes Observatory, was affected by air-currents from the warmed-up soil, George Ellery Hale had the idea of a tower telescope. In 1904, the 60-foot tower in Mt. Wilson was ready, in 1908 the 150-foot tower was built with the help of the Carnegie foundation. After World War I, Germany made heavy efforts to regain its former strong position in the field of science. Already in December 1919 - after the spectacular result of the English eclipse expedition in October 1919 - Erwin Finlay-Freundlich started a successful fund raising (“Einstein-Stiftungrdquo;) among German industrialists. The company Zeiss in Jena was responsible for the instrumentation of the 20-m solar tower, built in 1920-22. The optical design of the Einstein Tower in respect to light intensity surpassed even the Mt. Wilson solar observatory. Also abroad solar tower observatories were built in the 1920s: Utrecht,The Netherlands (1922), Canberra, Australia (1924), Arcetri, Italy (1926), Pasadena, California (1926) and Tokyo, Japan (1928). In the thirties, solar physics became important because of the solar maximum in 1938 and the new observational possibilities created by Bernard Lyot. At the end of the 1930s, Karl-Otto Kiepenheuer proposed to establish a solar tower observatory on Wendelstein in order to improve the predictions of radio interference by observing sunspots. By stressing the importance of the solar research for war efforts, Otto Heckmann of Göttingen observatory finally succeeded in winning the “Reichsluftfahrtministerium” to finance several solar observatories, like Wendelstein, Hainberg/Göttingen, Kanzelhöhe/Villach, and Schauinsland/Freiburg. Solar astronomy profited by the foundation of the new observatories - four of them existed still after the war. Abroad only the solar observatories of Oxford (1935) and the 50 foot tower of the McMath-Hulbert Observatory, University of Michigan (1936) should be mentioned. Only

  18. The Design of Akhmat Tower

    Directory of Open Access Journals (Sweden)

    Beardsley Sara

    2018-01-01

    Full Text Available Akhmat Tower is a 435m supertall building designed by Adrian Smith + Gordon Gill Architecture. It is currently under construction in the city of Grozny, in the Chechen Republic, in the North Caucasus region of Russia. The design of the tower was done during a collaborative process by a multi-disciplinary architectural and engineering team, based primarily in the United States and Russia. During this process, the designers considered many factors including, most primarily, the cultural and historical context, the structural requirements given the high seismicity of the region, and the client’s programmatic needs. The resulting crystalline-shaped tower is both an aesthetic statement and a performative architectural solution which will be a new landmark for Chechnya. “The Design of Akhmat Tower” describes in detail the design process including structural considerations, exterior wall design, building program, interior design, the tuned mass damper, and the use of building information modeling.

  19. Windfarms and telecommunications towers (Scotland)

    International Nuclear Information System (INIS)

    Munro, Hector; Kellett-Bowman, Elaine; Harris, David

    1996-01-01

    A debate in the United Kingdom House of Commons on the environmental impact of windfarms and telecommunications towers in Scotland is reported. Concern was expressed over the adverse visual impact of such structures in rural areas which are often of considerable natural beauty. Counter arguments were based on the positive effects of new technology. The need to reconcile environmental protection with technological innovation was expressed. A Government spokesman described the comprehensive planning policy framework which has been put in place to secure sound planning decisions on renewable energy developments and the conditions on amenity protection in the regulations governing the erection of telecommunications towers. (UK)

  20. Windfarms and telecommunications towers (Scotland)

    Energy Technology Data Exchange (ETDEWEB)

    Munro, Hector; Kellett-Bowman, Elaine; Harris, David [and others

    1996-10-30

    A debate in the United Kingdom House of Commons on the environmental impact of windfarms and telecommunications towers in Scotland is reported. Concern was expressed over the adverse visual impact of such structures in rural areas which are often of considerable natural beauty. Counter arguments were based on the positive effects of new technology. The need to reconcile environmental protection with technological innovation was expressed. A Government spokesman described the comprehensive planning policy framework which has been put in place to secure sound planning decisions on renewable energy developments and the conditions on amenity protection in the regulations governing the erection of telecommunications towers. (UK)

  1. Load-Direction-Derived Support Structures for Wind Turbines: A Lattice Tower Concept and Preparations for Future Certifications: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Jonkman, Jason [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Damiani, Rick R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Struve, Achim [University of Applied Sciences Flensburg; Faber, Torsten [University of Applied Sciences Flensburg; Ummenhofer, Thomas [Karlsruhe Institute of Technology

    2017-11-07

    The call for more cost-effective and environmentally friendly tower concepts is motivated by tower costs [1] and tower CO2-emission contributions [2], which are high relative to the whole wind turbine system. The proposed rotatable tower concept with yaw bearing at the bottom instead of the top of the tower will provide beneficial economic and environmental impacts to the turbine system. This wind alignment capability indicates a load-direction-derived tower design. By combining this approach with a lattice concept, large material and cost savings for the tower can be achieved. This paper presents a way to analyze and verify the proposed design through aero-servo-elastic simulations, which make future certifications of rotatable tower concepts viable. For this reason, the state-of-the-art, open-source lattice-tower finite-element-method (FEM) module SubDyn [10], developed by the National Renewable Energy Laboratory, has been modified to account for arbitrary member cross-sections. Required changes in the beam element stiffness and mass matrix formulation took place according to an energy method [13]. All validated adaptions will be usable within the aero-servo-elastic simulation framework FAST and are also beneficial for other nonrotatable lattice structures.

  2. ESTABLISHMENT OF AN INDUSTRY-DRIVEN CONSORTIUM FOCUSED ON IMPROVING THE PRODUCTION PERFORMANCE OF DOMESTIC STRIPPER WELLS

    Energy Technology Data Exchange (ETDEWEB)

    Joel L. Morrison

    2004-12-23

    The Pennsylvania State University, under contract to the U.S. Department of Energy, National Energy Technology Laboratory will establish, promote, and manage a national industry-driven Stripper Well Consortium (SWC) that will be focused on improving the production performance of domestic petroleum and/or natural gas stripper wells. The consortium creates a partnership with the U.S. petroleum and natural gas industries and trade associations, state funding agencies, academia, and the National Energy Technology Laboratory. This report serves as the fifteenth quarterly technical progress report for the SWC. Key activities for this reporting period include: (1) hosting the SWC spring proposal meeting in Golden Colorado, (2) planning of the upcoming SWC fall technology transfer meetings, and (3) recruiting the SWC base membership.

  3. ESTABLISHMENT OF AN INDUSTRY-DRIVEN CONSORTIUM FOCUSED ON IMPROVING THE PRODUCTION PERFORMANCE OF DOMESTIC STRIPPER WELLS

    Energy Technology Data Exchange (ETDEWEB)

    Joel L. Morrison

    2004-12-28

    The Pennsylvania State University, under contract to the U.S. Department of Energy, National Energy Technology Laboratory will establish, promote, and manage a national industry-driven Stripper Well Consortium (SWC) that will be focused on improving the production performance of domestic petroleum and/or natural gas stripper wells. The consortium creates a partnership with the U.S. petroleum and natural gas industries and trade associations, state funding agencies, academia, and the National Energy Technology Laboratory. This report serves as the first quarterly technical progress report for the SWC. Key activities for this reporting period include: (1) hosting the SWC spring proposal meeting in Golden Colorado, (2) planning of the upcoming SWC fall technology transfer meetings, and (3) recruiting the SWC base membership.

  4. Test preparation and lifetime measurement of very thin carbon stripper foils made by a controlled DC arc-discharge method

    CERN Document Server

    Sugai, I; Oyaizu, M; Kawakami, H; Hattori, Y; Kawasaki, K; Hayashizaki, N

    2002-01-01

    We have prepared very thin plastic supported carbon stripper foils (1.2+-0.3 mu g/cm sup 2) using a controlled DC arc-discharge (CDAD) method. The lifetime of these foils was measured with 3.2 MeV Ne sup + ions. These foils recorded lifetimes about four times longer at the maximum and three times longer on the average than those commercially available foils produced by evaporation-condensation.

  5. The solar towers of Chankillo

    OpenAIRE

    Sparavigna, Amelia Carolina

    2012-01-01

    An ancient solar observatory is composed by thirteen towers lined on a hill of a coastal desert of Peru. This is the Chankillo observatory. Here we discuss it, showing some simulations of the local sun direction. An analysis of the behaviour of shadows is also proposed.

  6. Dwelling towers of Czech castles

    Czech Academy of Sciences Publication Activity Database

    Durdík, Tomáš

    2009-01-01

    Roč. 63, - (2009), s. 139-150 ISSN 1875-2896. [Meeting of Europa Nostra Scientific Council /44./. Kilkenny, 27.09.2008-02.10.2008] Institutional research plan: CEZ:AV0Z80020508 Keywords : castle * castellology * dwelling tower * donjon * keep * medieval archaeology * architecture * Bohemia * Middle Ages Subject RIV: AC - Archeology, Anthropology, Ethnology

  7. Mobile Tower Radiation Protection System

    Directory of Open Access Journals (Sweden)

    Jabbar Slman Hussein

    2017-12-01

    Full Text Available Clean environment is one of the most necessarily needs for Human life. So what about mobile effect and its towers pollution? It's effect on public health? Effect of huge groan of mobile networks. In counting of these dangers that will harm us from mobile towers in the far run, was the reasons for writing this research, came this study to look at the mobile towers and mobile effects possible health harm for the purpose of diagnosis of these effects and to suggest ways that can be used to avoid or minimize the risks.  Faraday Cage, is the solution suggested here, also there are many other solutions for this problem, a Faraday cage is a metallic enclosure that stops the entry or escape of an EM field. Also, two experiments are accomplished, first one showing the effect of Faraday cage on preventing the EMR from mobile cellphone, and the second  experiment gives the effect of Faraday cage on preventing the EMR from mobile tower EMR on human health listed in the research, that have been done by using conducting shell (grid design according the EM wavelength used by three company's mobile working in Iraq, the result show good isolations.

  8. Good towers of function Fields

    DEFF Research Database (Denmark)

    Nguyen, Nhut

    of q. In this thesis, we study a construction using Drinfeld modules that produces explicitly defined families of algebraic curves that asymptotically achieve Ihara’s constant. Such families of curves can also be described using towers of function fields. Restated in this language the aim...

  9. ESTABLISHMENT OF AN INDUSTRY-DRIVEN CONSORTIUM FOCUSED ON IMPROVING THE PRODUCTION PERFORMANCE OF DOMESTIC STRIPPER WELLS

    Energy Technology Data Exchange (ETDEWEB)

    Joel L. Morrison

    2001-09-12

    The Pennsylvania State University, under contract to the US Department of Energy, National Energy Technology Laboratory will establish, promote, and manage a national industry-driven Stripper Well Consortium (SWC) that will be focused on improving the production performance of domestic petroleum and/or natural gas stripper wells. the consortium creates a partnership with the US petroleum and natural gas industries and trade associations, state funding agencies, academia, and the National Energy Technology Laboratory. This report serves as the third quarterly technical progress report for the SWC. During this reporting period the SWC entered into a co-funding arrangement with the New York State Energy Development Authority (NYSERDA) to provide an additional $100,000 in co-funding for stripper well production-orientated projects.The SWC hosted its first meeting in which members proposed research projects to the SWC membership. The meeting was held on April 9-10, 2001 in State College, Pennsylvania. Twenty three proposals were submitted to the SWC for funding consideration. Investigators of the proposed projects provided the SWC membership with a 20 minute (15 minute technical discussion, 5 minute question and answer session) presentation. Of the 23 proposals, the Executive Council approved $921,000 in funding for 13 projects. Penn State then immediately started the process of issuing subcontracts to the various projects approved for funding.

  10. Cooling tower modification for intermittent operation

    International Nuclear Information System (INIS)

    Midkiff, W.S.

    1975-03-01

    One of the cooling towers at Los Alamos Scientific Laboratory is being operated intermittently. The cooling tower has been modified to restrict air flow and to keep the tower from drying out. The modifications are relatively inexpensive, simple to operate, and have proved effective. (U.S.)

  11. An Optimal Unramified Tower of Function Fields

    DEFF Research Database (Denmark)

    Efficient construction of long AG--codes resulting from optimal towers of function fields is known to be difficult. In the following a tower which is both optimal and unramified, that is a tower in which all places are unramified after some level, is investigated in the hope that its simple...

  12. Porn star/stripper/escort: economic and sexual dynamics in a sex work career.

    Science.gov (United States)

    Escoffier, Jeffrey

    2007-01-01

    This article explores the career dynamics of performers in the gay male pornography industry, by focusing on a common career path- from porn star to stripper to escort. Between 1995 and 2005, most men performing in gay porn films, unlike contract actresses in the straight porn industry, have been unable to earn enough income to work exclusively as performers in front of the camera. The industry's constant search for new faces and fresh performers creates what sociologist Paul Cressey has called "the retrogressive dynamic": The longer a person works in a sexual occupation, the less one is paid, and the lower the status of the work venue. In the porn industry, one aspect of this process is referred to as "overexposure," during which the performer experiences a diminishing "fantasy potential" as fans lose erotic interest in the porn star who has appeared too frequently in too many movies. Performers attempt to confront the retrogressive dynamic by limiting the number of adult films in which they appear in a year, diversifying their sexual repertoire, or shifting into other roles within the industry (behind the camera, marketing, production, etc.). One common option is to pursue work in economically complementary forms of sex work such as stripping and escorting.

  13. Bottom head assembly

    International Nuclear Information System (INIS)

    Fife, A.B.

    1998-01-01

    A bottom head dome assembly is described which includes, in one embodiment, a bottom head dome and a liner configured to be positioned proximate the bottom head dome. The bottom head dome has a plurality of openings extending there through. The liner also has a plurality of openings extending there through, and each liner opening aligns with a respective bottom head dome opening. A seal is formed, such as by welding, between the liner and the bottom head dome to resist entry of water between the liner and the bottom head dome at the edge of the liner. In the one embodiment, a plurality of stub tubes are secured to the liner. Each stub tube has a bore extending there through, and each stub tube bore is coaxially aligned with a respective liner opening. A seat portion is formed by each liner opening for receiving a portion of the respective stub tube. The assembly also includes a plurality of support shims positioned between the bottom head dome and the liner for supporting the liner. In one embodiment, each support shim includes a support stub having a bore there through, and each support stub bore aligns with a respective bottom head dome opening. 2 figs

  14. Hybrid Tower, Designing Soft Structures

    DEFF Research Database (Denmark)

    Ramsgaard Thomsen, Mette; Tamke, Martin; Holden Deleuran, Anders

    2015-01-01

    predictions about the inherent interdependency and material dependent performance of the hybrid structure and (2) the inter-scalar design strategies for specification and fabrication. The first investigation focuses on the design pipelines developed between the implementation of realtime physics......This paper presents the research project Hybrid Tower, an interdisciplinary collaboration between CITA—Centre for IT and Architecture, KET—Department for Structural Design and Technology, Fibrenamics, Universidade do Minho Guimarães, AFF a. ferreira & filhos, sa, Caldas de Vizela, Portugal...... and Essener Labor für Leichte Flächentragwerke, Universität Duisburg-Essen. Hybrid Tower is a hybrid structural system combining bending active compression members and tensile members for architectural design. The paper presents two central investigations: (1) the creation of new design methods that embed...

  15. Sea-water intake tower works for Hamaoka Nuclear Power Station No. 2 Plant

    International Nuclear Information System (INIS)

    Satake, Norimoto; Sugaya, Yoshinobu; Sugimoto, Tadao

    1976-01-01

    It was determined to adopt tunnel system based on the conclusion of negotiation with local people, specifically fishermen, for the sea water intake arrangement in Hamaoka Nuclear Power Station. The main factors for determining the location of the intake tower included marine conditions such as waves and littoral sand drift, and the sea-bottom topographic features and geology of tunnel route, for which field examination, hydraulic experiments and the research and investigation on the method of construction were carried out. These results in the No.2 tower installation at the point 65 m to the east of the No.1 tower. The construction of the tower is described on the manufacture and conveyance of steel caisson, land works at Omaezaki and temporary assembly works on the sea. Then the details of tower installation and the works on site are reported. Fortunately the difficult sea works have been satisfactorily completed earlier than planned, without any accident. The construction facilities utilizing a pilot tunnel seem to have made the better achievement than expected. In spite of the results, the lifting up, off-shore conveyance, and installation of the intake tower caisson, a superheavy structure of weighting up to total 2900 ton, were critical works. (Wakatsuki, Y.)

  16. Self-assembled granular towers

    Science.gov (United States)

    Pacheco-Vazquez, Felipe; Moreau, Florian; Vandewalle, Nicolas; Dorbolo, Stephan; GroupResearch; Applications in Statistical Physics Team

    2013-03-01

    When some water is added to sand, cohesion among the grains is induced. In fact, only 1% of liquid volume respect to the total pore space of the sand is necessary to built impressive sandcastles. Inspired on this experience, the mechanical properties of wet piles and sand columns have been widely studied during the last years. However, most of these studies only consider wet materials with less than 35% of liquid volume. Here we report the spontaneous formation of granular towers produced when dry sand is poured on a highly wet sand bed: The impacting grains stick on the wet grains due to instantaneous liquid bridges created during the impact. The grains become wet by the capillary ascension of water and the process continues, giving rise to stable narrow sand towers. Actually, the towers can reach the maximum theoretical limit of stability predicted by previous models, only expected for low liquid volumes. The authors would like to thank FNRS and Conacyt Mexico for financial support. FPV is a beneficiary of a movility grant from BELSPO/Marie Curie and the University of Liege.

  17. Validation of the Dynamic Wake Meander model with focus on tower loads

    Science.gov (United States)

    Larsen, T. J.; Larsen, G. C.; Pedersen, M. M.; Enevoldsen, K.; Madsen, H. A.

    2017-05-01

    This paper presents a comparison between measured and simulated tower loads for the Danish offshore wind farm Nysted 2. Previously, only limited full scale experimental data containing tower load measurements have been published, and in many cases the measurements include only a limited range of wind speeds. In general, tower loads in wake conditions are very challenging to predict correctly in simulations. The Nysted project offers an improved insight to this field as six wind turbines located in the Nysted II wind farm have been instrumented to measure tower top and tower bottom moments. All recorded structural data have been organized in a database, which in addition contains relevant wind turbine SCADA data as well as relevant meteorological data - e.g. wind speed and wind direction - from an offshore mast located in the immediate vicinity of the wind farm. The database contains data from a period extending over a time span of more than 3 years. Based on the recorded data basic mechanisms driving the increased loading experienced by wind turbines operating in offshore wind farm conditions have been identified, characterized and modeled. The modeling is based on the Dynamic Wake Meandering (DWM) approach in combination with the state-of-the-art aeroelastic model HAWC2, and has previously as well as in this study shown good agreement with the measurements. The conclusions from the study have several parts. In general the tower bending and yaw loads show a good agreement between measurements and simulations. However, there are situations that are still difficult to match. One is tower loads of single-wake operation near rated ambient wind speed for single wake situations for spacing’s around 7-8D. A specific target of the study was to investigate whether the largest tower fatigue loads are associated with a certain downstream distance. This has been identified in both simulations and measurements, though a rather flat optimum is seen in the measurements.

  18. Adiabatic Rearrangement of Hollow PV Towers

    OpenAIRE

    Eric A Hendricks; Wayne H Schubert

    2010-01-01

    Diabatic heating from deep moist convection in the hurricane eyewall produces a towering annular structure of elevated potential vorticity (PV). This structure has been referred to as a hollow PV tower. The sign reversal of the radial gradient of PV satisfies the Charney-Stern necessary condition for combined barotropic-baroclinic instability. For thin enough annular structures, small perturbations grow exponentially, extract energy from the mean flow, and lead to hollow tower breakdown, with...

  19. Plumes from one and two cooling towers

    International Nuclear Information System (INIS)

    Kannberg, L.D.; Onishi, Y.

    1978-01-01

    Use of mechanical- and natural-draft cooling towers is expanding in the United States in response to pressures for better resource allocation and preservation. Specifically, increasing public and regulatory concern over the effects of the intake and discharge of large volumes of cooling water has encouraged electric utilities to accept cooling towers as the primary method of removing condenser waste heat even though once-through cooling is considerably less expensive. Other factors encouraging the use of cooling towers include small water supply and consumption rates, reduction in land requirements (compared to cooling ponds or lakes), and operational flexibility. The growing demand for electric energy should also add to the increase of cooling tower use. The experimental program and its comparison to model prediction suggest that optimal siting of cooling towers, particularly multiple towers, is a task requiring knowledge of ambient wind history, plume dynamics, and tower operating conditions. Based on the tower wake effects and on the results for interaction of plumes from two cooling towers, site terrain may be a very significant factor in plume dynamics and interaction

  20. Optimal Inflatable Space Towers of High Height

    Science.gov (United States)

    Bolonkin, Alexander

    2002-01-01

    Author provides theory and computations for building inflatable space towers up to a hundred km in height. These towers can be used for tourism; scientific observation of space, earth's surface, weather, top atmosphere, as well as for radio, television, and communication transmissions. These towers can also be used to launch space ships and Earth satellites. These projects are not expensive and do not require rockets. They require thin strong films composed from artificial fibers and fabricated by current industry. Towers can be built using present technology. Towers can be used (for tourism, communication, etc.) during the construction process and provide self-financing for further construction. The tower design does not require work at high altitudes; all construction can be done at the earth's surface. The transport system for this tower consists a small engine (used only for friction compensation) located at the earth's surface. The tower is separated into sections and has special protection mechanism in case of a damage. Problems involving security, control, repair, and stability of the proposed towers are addressed in subsequent publications. The author is prepared to discuss these and other problems with serious organizations desiring to research and develop these projects.

  1. An Optimal Unramified Tower of Function Fields

    DEFF Research Database (Denmark)

    Brander, Kristian

    2008-01-01

    Efficient construction of long algebraic geometric--codes resulting from optimal towers of function fields is known to be difficult. In the following a tower which is both optimal and unramified after its third level, is investigated in the hope that its simple ramification structure can be explo......Efficient construction of long algebraic geometric--codes resulting from optimal towers of function fields is known to be difficult. In the following a tower which is both optimal and unramified after its third level, is investigated in the hope that its simple ramification structure can...

  2. Optimal inflatable space towers of high height

    Science.gov (United States)

    Bolonkin, A.

    Author suggested, developed theory, and computed some projects of an optimal inflatable space tower of the heights some hundreds km. These towers can be used for tourism, scientist observation of space, Earth surface, Earth weather, Earth top atmosphere, and for radio, TV, communication transmissions. These towers can be used for launching of the space ships and Earth s atellites. The computed projects not expensive, do not request rockets. They need only in thin strong films composed from the artificial fibers and fabricated by a current industry. Towers can be built by a current technology. Towers can be explored (for tourism, communication, etc.) in a time of the construction process and give a profit, self- financing for further constriction. They can permanent increase their height. The tower design does not request a work at the high altitudes. All construction works will be making at the Earth surface. Author suggests the transport system for this tower of a high capability, which does not request a power energy issue. The small engine (only for a friction compensation) is located at the Earth surface. The tower is separated on sections and has a special protection of a case of a damage. It is considered also the problems of security, control, repair, etc. of the suggested towers. The author has also solved additional problems, which appear in these projects and which can look as difficult for the given proposal and current technology. The author is prepared to discuss the problems with serious organizations, which want to research and develop these projects.

  3. Summer Bottom Trawl Survey

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Sampling the coastal waters of the Gulf of Maine using the Northeast Fishery Science Center standardized bottom trawl has been problematic due to large areas of hard...

  4. The Bottom Boundary Layer

    Science.gov (United States)

    Trowbridge, John H.; Lentz, Steven J.

    2018-01-01

    The oceanic bottom boundary layer extracts energy and momentum from the overlying flow, mediates the fate of near-bottom substances, and generates bedforms that retard the flow and affect benthic processes. The bottom boundary layer is forced by winds, waves, tides, and buoyancy and is influenced by surface waves, internal waves, and stratification by heat, salt, and suspended sediments. This review focuses on the coastal ocean. The main points are that (a) classical turbulence concepts and modern turbulence parameterizations provide accurate representations of the structure and turbulent fluxes under conditions in which the underlying assumptions hold, (b) modern sensors and analyses enable high-quality direct or near-direct measurements of the turbulent fluxes and dissipation rates, and (c) the remaining challenges include the interaction of waves and currents with the erodible seabed, the impact of layer-scale two- and three-dimensional instabilities, and the role of the bottom boundary layer in shelf-slope exchange.

  5. Spring Bottom Trawl Survey

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The standardized NEFSC Spring Bottom Trawl Survey was initiated in 1968 and covered an area from Cape Hatteras, NC, to Nova Scotia, Canada, at depths >27m....

  6. Winter Bottom Trawl Survey

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The standardized NEFSC Winter Bottom Trawl Survey was initiated in 1992 and covered offshore areas from the Mid-Atlantic to Georges Bank. Inshore strata were covered...

  7. Fall Bottom Trawl Survey

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The standardized NEFSC Fall Bottom Trawl Survey was initiated in 1963 and covered an area from Hudson Canyon, NY to Nova Scotia, Canada. Throughout the years,...

  8. Tower Water-Vapor Mixing Ratio

    Energy Technology Data Exchange (ETDEWEB)

    Guastad, Krista; Riihimaki, Laura; none,

    2013-04-01

    The purpose of the Tower Water-Vapor Mixing Ratio (TWRMR) value-added product (VAP) is to calculate water-vapor mixing ratio at the 25-meter and 60-meter levels of the meteorological tower at the Southern Great Plains (SGP) Central Facility.

  9. Fire ants perpetually rebuild sinking towers

    Science.gov (United States)

    Phonekeo, Sulisay; Mlot, Nathan; Monaenkova, Daria; Hu, David L.; Tovey, Craig

    2017-07-01

    In the aftermath of a flood, fire ants, Solenopsis invicta, cluster into temporary encampments. The encampments can contain hundreds of thousands of ants and reach over 30 ants high. How do ants build such tall structures without being crushed? In this combined experimental and theoretical study, we investigate the shape and rate of construction of ant towers around a central support. The towers are bell shaped, consistent with towers of constant strength such as the Eiffel tower, where each element bears an equal load. However, unlike the Eiffel tower, the ant tower is built through a process of trial and error, whereby failed portions avalanche until the final shape emerges. High-speed and novel X-ray videography reveal that the tower constantly sinks and is rebuilt, reminiscent of large multicellular systems such as human skin. We combine the behavioural rules that produce rafts on water with measurements of adhesion and attachment strength to model the rate of growth of the tower. The model correctly predicts that the growth rate decreases as the support diameter increases. This work may inspire the design of synthetic swarms capable of building in vertical layers.

  10. Wind turbine tower for storing hydrogen and energy

    Science.gov (United States)

    Fingersh, Lee Jay [Westminster, CO

    2008-12-30

    A wind turbine tower assembly for storing compressed gas such as hydrogen. The tower assembly includes a wind turbine having a rotor, a generator driven by the rotor, and a nacelle housing the generator. The tower assembly includes a foundation and a tubular tower with one end mounted to the foundation and another end attached to the nacelle. The tower includes an in-tower storage configured for storing a pressurized gas and defined at least in part by inner surfaces of the tower wall. In one embodiment, the tower wall is steel and has a circular cross section. The in-tower storage may be defined by first and second end caps welded to the inner surface of the tower wall or by an end cap near the top of the tower and by a sealing element attached to the tower wall adjacent the foundation, with the sealing element abutting the foundation.

  11. Carbon Nanotube Tower-Based Supercapacitor

    Science.gov (United States)

    Meyyappan, Meyya (Inventor)

    2012-01-01

    A supercapacitor system, including (i) first and second, spaced apart planar collectors, (ii) first and second arrays of multi-wall carbon nanotube (MWCNT) towers or single wall carbon nanotube (SWCNT) towers, serving as electrodes, that extend between the first and second collectors where the nanotube towers are grown directly on the collector surfaces without deposition of a catalyst and without deposition of a binder material on the collector surfaces, and (iii) a porous separator module having a transverse area that is substantially the same as the transverse area of at least one electrode, where (iv) at least one nanotube tower is functionalized to permit or encourage the tower to behave as a hydrophilic structure, with increased surface wettability.

  12. Mechanical Properties of UHPFRC Joint for FORIDA Wind Turbine Tower

    DEFF Research Database (Denmark)

    Sørensen, Eigil Verner

    FORIDA Development, Vestas and Aalborg University are currently undertaking the project “FORIDA Hybrid Towers – The towers for next generation of wind turbines”, aiming to develop a new wind turbine tower structure (The FORIDA Tower) for very tall turbines. The tower is going to be a hybrid of ma...... of materials combining steel and Ultra High Performance Fibre Reinforced Concrete (UHPFRC), applied as precast units. The FORIDA Tower is competitive regarding price, design, flexibility and durability....

  13. Mechanical Properties of UHPFRC Joint for FORIDA Wind Turbine Tower

    DEFF Research Database (Denmark)

    Sørensen, Eigil Verner

    FORIDA Development, Vestas and Aalborg University are currently undertaking the project “FORIDA Hybrid Towers – The towers for next generation of wind turbines”, aiming to develop a new wind turbine tower structure (The FORIDA Tower) for very tall turbines. The tower is going to be a hybrid...... of materials combining steel and Ultra High Performance Fibre Reinforced Concrete (UHPFRC), applied as precast units. The FORIDA Tower is competitive regarding price, design, flexibility and durability....

  14. Augmented Reality Tower Technology Assessment

    Science.gov (United States)

    Reisman, Ronald J.; Brown, David M.

    2009-01-01

    Augmented Reality technology may help improve Air Traffic Control Tower efficiency and safety during low-visibility conditions. This paper presents the assessments of five off-duty controllers who shadow-controlled' with an augmented reality prototype in their own facility. Initial studies indicated unanimous agreement that this technology is potentially beneficial, though the prototype used in the study was not adequate for operational use. Some controllers agreed that augmented reality technology improved situational awareness, had potential to benefit clearance, control, and coordination tasks and duties and could be very useful for acquiring aircraft and weather information, particularly aircraft location, heading, and identification. The strongest objections to the prototype used in this study were directed at aircraft registration errors, unacceptable optical transparency, insufficient display performance in sunlight, inadequate representation of the static environment and insufficient symbology.

  15. Charmed Bottom Baryon Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Zachary S; Detmold, William; Meinel, Stefan; Orginos, Kostas

    2014-11-01

    The spectrum of doubly and triply heavy baryons remains experimentally unexplored to a large extent. Although the detection of such heavy particle states may lie beyond the reach of exper- iments for some time, it is interesting compute this spectrum from QCD and compare results between lattice calculations and continuum theoretical models. Several lattice calculations ex- ist for both doubly and triply charmed as well as doubly and triply bottom baryons. Here, we present preliminary results from the first lattice calculation of doubly and triply heavy baryons including both charm and bottom quarks. We use domain wall fermions for 2+1 flavors (up down and strange) of sea and valence quarks, a relativistic heavy quark action for the charm quarks, and non-relativistic QCD for the heavier bottom quarks. We present preliminary results for the ground state spectrum.

  16. Bottom-linked innovation

    DEFF Research Database (Denmark)

    Kristensen, Catharina Juul

    2018-01-01

    Employee-driven innovation is gaining ground as a strategy for developing sustainable organisations in the public and private sector. This type of innovation is characterised by active employee participation, and the bottom-up perspective is often emphasised. This article explores an issue that has...... hitherto been paid little explicit attention, namely collaboration between middle managers and employees in innovation processes. In contrast to most studies, middle managers and employees are here both subjects of explicit investigation. The collaboration processes explored in this article are termed...... ‘bottom-linked innovation’. The empirical analysis is based on an in-depth qualitative study of bottom-linked innovation in a public frontline institution in Denmark. By combining research on employee-driven innovation and middle management, the article offers new insights into such collaborative...

  17. Performance characteristics of a shower cooling tower

    International Nuclear Information System (INIS)

    Qi Xiaoni; Liu Zhenyan; Li Dandan

    2007-01-01

    This study was prompted by the need to design towers for applications in which, due to salt deposition on the packing and subsequent blockage, the use of tower packing is not practical. In contrast to conventional cooling towers, the cooling tower analyzed in this study is void of fill. By means of efficient atomization nozzles, a shower cooling tower (SCT) is possible to be applied in industry, which, in terms of water cooling, energy saving and equipment investing, is better than conventional packed cooling towers. However, no systematic thermodynamic numerical method could be found in the literature up to now. Based on the kinetic model and mass and heat transfer model, this paper has developed a one dimensional model for studying the motional process and evaporative cooling process occurring at the water droplet level in the SCT. The finite difference approach is used for three motional processes to obtain relative parameters in each different stage, and the possibility of the droplets being entrained outside the tower is fully analyzed. The accuracy of this model is checked by practical operational results from a full scale prototype in real conditions, and some exclusive factors that affect the cooling characteristics for the SCT are analyzed in detail. This study provides the theoretical foundation for practical application of the SCT in industry

  18. Blasting response of the Eiffel Tower

    Science.gov (United States)

    Horlyck, Lachlan; Hayes, Kieran; Caetano, Ryan; Tahmasebinia, Faham; Ansourian, Peter; Alonso-Marroquin, Fernando

    2016-08-01

    A finite element model of the Eiffel Tower was constructed using Strand7 software. The model replicates the existing tower, with dimensions justified through the use of original design drawings. A static and dynamic analysis was conducted to determine the actions of the tower under permanent, imposed and wind loadings, as well as under blast pressure loads and earthquake loads due to an explosion. It was observed that the tower utilises the full axial capacity of individual members by acting as a `truss of trusses'. As such, permanent and imposed loads are efficiently transferred to the primary columns through compression, while wind loads induce tensile forces in the windward legs and compressive forces in the leeward. Under blast loading, the tower experienced both ground vibrations and blast pressures. Ground vibrations induced a negligibly small earthquake loading into the structure which was ignored in subsequent analyses. The blast pressure was significant, and a dynamic analysis of this revealed that further research is required into the damping qualities of the structure due to soil and mechanical properties. In the worst case scenario, the blast was assumed to completely destroy several members in the adjacent leg. Despite this weakened condition, it was observed that the tower would still be able to sustain static loads, at least for enough time for occupant evacuation. Further, an optimised design revealed the structure was structurally sound under a 46% reduction of the metal tower's mass.

  19. Bottom and top physics

    International Nuclear Information System (INIS)

    Foley, K.J.; Fridman, A.; Gilman, F.J.; Herten, G.; Hinchliffe, I.; Jawahery, A.; Sanda, A.; Schmidt, M.P.; Schubert, K.R.

    1987-09-01

    The production of bottom quarks at the SSC and the formalism and phenomenology of observing CP violation in B meson decays is discussed. The production of a heavy t quark which decays into a real W boson, and what we might learn from its decays is examined

  20. Asbestos in cooling-tower waters

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, B.A.G.

    1977-12-01

    Fill material in natural- or mechanical-draft cooling towers can be manufactured from a variety of materials, including asbestos cement or asbestos paper. To aid in the environmental impact assessment of cooling towers containing these asbestos types of fill, information on these materials was obtained from cooling-tower vendors and users. Samples of makeup, basin, and blowdown waters at a number of operating cooling towers were obtained, and identification and enumeration of asbestos in the samples were performed by transmission electron microscopy, selected-area electron diffraction, and energy-dispersive x-ray analysis. Asbestos fibers were detected in cooling-tower water at 10 of the 18 sites sampled in the study. At all but three sites, the fibers were detected in cooling-tower basin or blowdown samples, with no fibers detected in the makeup water. The fibers were identified as chrysotile at all sites except one. Concentrations were on the order of 10/sup 6/ to 10/sup 8/ fibers/liter of water, with mass concentrations between <0.1 ..mu..g/liter to 37 ..mu..g/liter. The maximum concentrations of asbestos fibers in air near ground due to drift from cooling towers were estimated (using models) to be on the order of asbestos concentrations reported for ambient air up to distances of 4 km downwind of the towers. The human health hazard due to abestos in drinking-water supplies is not clear. Based on current information, the concentrations of asbestos in natural waters after mixing with cooling-tower blowdown containing 10/sup 6/ to 10/sup 8/ fibers/liter will pose little health risk. These conclusions may need to be revised if future epidemiological studies so indicate.

  1. Waste rice seed in conventional and stripper-head harvested fields in California: Implications for wintering waterfowl

    Science.gov (United States)

    Fleskes, Joseph P.; Halstead, Brian J.; Casazza, Michael L.; Coates, Peter S.; Kohl, Jeffrey D.; Skalos, Daniel A.

    2012-01-01

    Waste rice seed is an important food for wintering waterfowl and current estimates of its availability are needed to determine the carrying capacity of rice fields and guide habitat conservation. We used a line-intercept method to estimate mass-density of rice seed remaining after harvest during 2010 in the Sacramento Valley (SACV) of California and compared results with estimates from previous studies in the SACV and Mississippi Alluvial Valley (MAV). Posterior mean (95% credible interval) estimates of total waste rice seed mass-density for the SACV in 2010 were 388 (336–449) kg/ha in conventionally harvested fields and 245 (198–307) kg/ha in stripper-head harvested fields; the 2010 mass-density is nearly identical to the mid-1980s estimate for conventionally harvested fields but 36% lower than the mid-1990s estimate for stripped fields. About 18% of SACV fields were stripper-head harvested in 2010 vs. 9–15% in the mid-1990s and 0% in the mid-1980s; but due to a 50% increase in planted rice area, total mass of waste rice seed in SACV remaining after harvest in 2010 was 43% greater than in the mid-1980s. However, total mass of seed-eating waterfowl also increased 82%, and the ratio of waste rice seed to seed-eating waterfowl mass was 21% smaller in 2010 than in the mid-1980s. Mass-densities of waste rice remaining after harvest in SACV fields are within the range reported for MAV fields. However, because there is a lag between harvest and waterfowl use in the MAV but not in the SACV, seed loss is greater in the MAV and estimated waste seed mass-density available to wintering waterfowl in SACV fields is about 5–30 times recent MAV estimates. Waste rice seed remains an abundant food source for waterfowl wintering in the SACV, but increased use of stripper-head harvesters would reduce this food. To provide accurate data on carrying capacities of rice fields necessary for conservation planning, trends in planted rice area, harvest method, and postharvest field

  2. The Schmehausen cable net cooling tower

    International Nuclear Information System (INIS)

    Schlaich, J.; Mayr, G.; Weber, P.; Jasch, E.

    1976-01-01

    The prototype of a large cable net shell as a natural-draught cooling tower for the THTR-300 is presented. Results of wind tunnel tests and calculations are given, and the capacity is discussed. Design features of the main components are presented in illustrations and are described with regard to the construction process of the cooling tower. Finally, it is shown that the cable net cooling tower is a suitable construction for large dimensions and caving-in or seismic areas. (orig./HP) [de

  3. Drop Tower Facility at Queensland University of Technology

    Science.gov (United States)

    Plagens, Owen; Castillo, Martin; Steinberg, Theodore; Ong, Teng-Cheong

    The Queensland University of Technology (QUT) Drop Tower Facility is a {raise.17exscriptstyle˜}2.1 second, 21.3 m fall, dual capsule drop tower system. The dual capsule comprises of an uncoupled exterior hollow drag shield that experiences drag by the ambient atmosphere with the experimental capsule falling within the drag shield. The dual capsule system is lifted to the top of the drop tower via a mechanical crane and the dropping process is initiated by the cutting of a wire coupling the experimental package and suspending the drag shield. The internal experimental capsule reaches the bottom of the drag shield floor just prior to the deceleration stage at the air bag and during this time experience gravity levels of {raise.17exscriptstyle˜}10textsuperscript{-6} g. The deceleration system utilizes an inflatable airbag where experimental packages can be designed to experience a maximum deceleration of {raise.17exscriptstyle˜}10textsuperscript{18} g for {raise.17exscriptstyle˜}0.1 seconds. The drag shield can house experimental packages with a maximum diameter of 0.8 m and height of 0.9 m. The drag shield can also be used in foam mode, where the walls are lined with foam and small experiments can be dropped completely untethered. This mode is generally used for the study of microsatellite manipulation. Payloads can be powered by on-board power systems with power delivered to the experiment until free fall occurs. Experimental data that can be collected includes but is not limited to video, temperature, pressure, voltage/current from the power supply, and triggering mechanisms outputs which are simultaneously collected via data logging systems and high speed video recording systems. Academic and commercial projects are currently under investigation at the QUT Drop Tower Facility and collaboration is openly welcome at this facility. Current research includes the study of heterogeneously burning metals in oxygen which is aimed at fire safety applications and

  4. Wind towers architecture, climate and sustainability

    CERN Document Server

    Bahadori, Mehdi N; Sayigh, Ali

    2014-01-01

    This book offers a holistic treatment of wind towers, from their underlying scientific principles to design and operation. Includes suggestions for optimization based on the authors' own research findings from recent analytical studies.

  5. Performance Analysis of Tower Watch Camera Systems

    National Research Council Canada - National Science Library

    Hansen, Richard

    2001-01-01

    ...) system with integrated image intensification and long-range thermal (infrared) imaging. The goal was to determine the extent to which remote monitoring of rough inlet bar conditions and vessel traffic could reduce the need to staff a watch tower...

  6. Design and operation of hybrid cooling towers

    International Nuclear Information System (INIS)

    Alt, W.

    1987-01-01

    The first hybrid cooling tower at a coal-fired power station with a waste heat output of 550 MW has been in operation since the middle of 1985. Experience during the construction stage and the initial period of operation has confirmed the correctness of the design standards and of the design itself and, of course, also offers a wealth of knowledge to be observed on future construction projects. A second cooling tower of similar design is being erected at the present time. This cooling tower serves a power station unit with 2500 MW of waste heat output. The programme for this cooling tower offers the possibility for all the accumulated and evaluated experience to be of influence both on the design and also on the method of operation. This paper reports on the details. (orig.) [de

  7. LaGuardia air traffic control tower.

    Science.gov (United States)

    2011-01-01

    To celebrate FAA and its LaGuardia Airport employees past, : present, and future this booklet outlines the airports history and accomplishments and includes copies of some of the photographs in the : air traffic control towers history g...

  8. Cooling tower water ozonation at Southern University

    International Nuclear Information System (INIS)

    Chen, C.C.; Knecht, A.T.; Trahan, D.B.; Yaghi, H.M.; Jackson, G.H.; Coppenger, G.D.

    1990-01-01

    Cooling-tower water is a critical utility for many industries. In the past, inexpensive water coupled with moderate regulation of discharge water led to the neglect of the cooling tower as an energy resource. Now, with the increased cost of chemical treatment and tough EPA rules and regulations, this situation is rapidly changing. The operator of the DOE Y-12 Plant in Oak Ridge as well as many other industries are forced to develop an alternate method of water treatment. The cooling tower is one of the major elements in large energy systems. The savings accrued from a well engineered cooling tower can be a significant part of the overall energy conservation plan. During a short-term ozonation study between 1987-1988, the Y-12 Plant has been successful in eliminating the need for cooling tower treatment chemicals. However, the long-term impact was not available. Since April 1988, the ozone cooling water treatment study at the Y-12 Plant has been moved to the site at Southern University in Baton Rouge, Louisiana. The purpose of this continued study is to determine whether the use of ozonation on cooling towers is practical from an economic, technical and environmental standpoint. This paper discusses system design, operating parameter and performance testing of the ozonation system at Southern University

  9. Biofouling control of industrial seawater cooling towers

    KAUST Repository

    Albloushi, Mohammed

    2017-11-01

    The use of seawater in cooling towers for industrial applications has much merit in the Gulf Cooperation Council countries due to the scarcity and availability of fresh water. Seawater make-up in cooling towers is deemed the most feasible because of its unlimited supply in coastal areas. Such latent-heat removal with seawater in cooling towers is several folds more efficient than sensible heat extraction via heat exchangers. Operational challenges such as scaling, corrosion, and biofouling are a major challenge in conventional cooling towers, where the latter is also a major issue in seawater cooling towers. Biofouling can significantly hamper the efficiency of cooling towers. The most popular methods used in cooling treatment to control biofouling are disinfection by chlorination. However, the disadvantages of chlorination are formation of harmful disinfection byproducts in the presence of high organic loading and safety concerns in the storage of chlorine gas. In this study, the research focuses on biofouling control in seawater cooling towers by investigating two different approaches. The first strategy addresses the use of alternative oxidants (i.e. ozone micro-bubbles and chlorine dioxide) in treatment of cooling towers. The second strategy investigates removing nutrients in seawater using granular activated carbon filter column and ultrafiltration to prevent the growth of microorganisms. Laboratory bench-scale tests in terms of temperature, cycle of concentration, dosage, etc. indicated that, at lower oxidant dosages (total residual oxidant (TRO) equivalent = 0.1 mg/l Cl2), chlorine dioxide had a better disinfection effect than chlorine and ozone. The performance of oxidizing biocides at pilot scale, operating at assorted conditions, showed that for the disinfectants tested, ozone could remove 95 % bioactivity of total number of bacteria and algae followed by chlorine dioxide at 85%, while conventional chlorine dosing only gave 60% reduction in bioactivities

  10. Adiabatic Rearrangement of Hollow PV Towers

    Directory of Open Access Journals (Sweden)

    Eric A Hendricks

    2010-10-01

    Full Text Available Diabatic heating from deep moist convection in the hurricane eyewall produces a towering annular structure of elevated potential vorticity (PV. This structure has been referred to as a hollow PV tower. The sign reversal of the radial gradient of PV satisfies the Charney-Stern necessary condition for combined barotropic-baroclinic instability. For thin enough annular structures, small perturbations grow exponentially, extract energy from the mean flow, and lead to hollow tower breakdown, with significant vortex structural and intensity change. The three-dimensional adiabatic rearrangements of two prototypical hurricane-like hollow PV towers (one thick and one thin are examined in an idealized framework. For both hollow towers, dynamic instability causes air parcels with high PV to be mixed into the eye preferentially at lower levels, where unstable PV wave growth rates are the largest. Little or no mixing is found to occur at upper levels. The mixing at lower and middle levels is most rapid for the breakdown of the thin hollow tower, consistent with previous barotropic results. For both hollow towers, this advective rearrangement of PV affects the tropical cyclone structure and intensity in a number of ways. First, the minimum central pressure and maximum azimuthal mean velocity simultaneously decrease, consistent with previous barotropic results. Secondly, isosurfaces of absolute angular momentum preferentially shift inward at low levels, implying an adiabatic mechanism by which hurricane eyewall tilt can form. Thirdly, a PV bridge, similar to that previously found in full-physics hurricane simulations, develops as a result of mixing at the isentropic levels where unstable PV waves grow most rapidly. Finally, the balanced mass field resulting from the PV rearrangement is warmer in the eye between 900 and 700 hPa. The location of this warming is consistent with observed warm anomalies in the eye, indicating that in certain instances the hurricane

  11. Aerodynamical errors on tower mounted wind speed measurements due to the presence of the tower

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, H. [Uppsala Univ. (Sweden). Dept. of Meteorology; Dahlberg, J.Aa. [Aeronautical Research Inst. of Sweden, Bromma (Sweden)

    1996-12-01

    Field measurements of wind speed from two lattice towers showed large differences for wind directions where the anemometers of both towers should be unaffected by any upstream obstacle. The wind speed was measured by cup anemometers mounted on booms along the side of the tower. A simple wind tunnel test indicates that the boom, for the studied conditions, could cause minor flow disturbances. A theoretical study, by means of simple 2D flow modelling of the flow around the mast, demonstrates that the tower itself could cause large wind flow disturbances. A theoretical study, based on simple treatment of the physics of motion of a cup anemometer, demonstrates that a cup anemometer is sensitive to velocity gradients across the cups and responds clearly to velocity gradients in the vicinity of the tower. Comparison of the results from the theoretical study and field tests show promising agreement. 2 refs, 8 figs

  12. Two-dimensional thermal simulations of aluminum and carbon ion strippers for experiments at SPIRAL2 using the highest beam intensities

    International Nuclear Information System (INIS)

    Tahir, N.A.; Kim, V.; Lamour, E.; Lomonosov, I.V.; Piriz, A.R.; Rozet, J.P.; Stöhlker, Th.; Sultanov, V.; Vernhet, D.

    2012-01-01

    In this paper we report on two-dimensional numerical simulations of heating of a rotating, wheel shaped target impacted by the full intensity of the ion beam that will be delivered by the SPIRAL2 facility at Caen, France. The purpose of this work is to study heating of solid targets that will be used to strip the fast ions of SPIRAL2 to the required high charge state for the FISIC (Fast Ion–Slow Ion Collision) experiments. Strippers of aluminum with different emissivities and of carbon are exposed to high beam current of different ion species as oxygen, neon and argon. These studies show that carbon, due to its much higher sublimation temperature and much higher emissivity, is more favorable compared to aluminum. For the highest beam intensities, an aluminum stripper does not survive. However, problem of the induced thermal stresses and long term material fatigue needs to be investigated before a final conclusion can be drawn.

  13. Two-dimensional thermal simulations of aluminum and carbon ion strippers for experiments at SPIRAL2 using the highest beam intensities

    Science.gov (United States)

    Tahir, N. A.; Kim, V.; Lamour, E.; Lomonosov, I. V.; Piriz, A. R.; Rozet, J. P.; Stöhlker, Th.; Sultanov, V.; Vernhet, D.

    2012-11-01

    In this paper we report on two-dimensional numerical simulations of heating of a rotating, wheel shaped target impacted by the full intensity of the ion beam that will be delivered by the SPIRAL2 facility at Caen, France. The purpose of this work is to study heating of solid targets that will be used to strip the fast ions of SPIRAL2 to the required high charge state for the FISIC (Fast Ion-Slow Ion Collision) experiments. Strippers of aluminum with different emissivities and of carbon are exposed to high beam current of different ion species as oxygen, neon and argon. These studies show that carbon, due to its much higher sublimation temperature and much higher emissivity, is more favorable compared to aluminum. For the highest beam intensities, an aluminum stripper does not survive. However, problem of the induced thermal stresses and long term material fatigue needs to be investigated before a final conclusion can be drawn.

  14. The shape of natural draft cooling towers

    International Nuclear Information System (INIS)

    Grange, J.L.

    1992-07-01

    The shape of cooling towers is more often designed empirically. There, it is considered from a theoretical point of view. The analysis of dynamic of natural draft and of the air flow in a cooling tower shell is presented. It is shown, that although it is convergent, a tower works like a diffuser for pressure recovery. And it is turbulence that produces a transfer of kinetic energy and allows a good operation of the diffusor. The equations permit to define a shell profile which depends upon the operating conditions of the cooling tower. In the same way, a stability criteria for natural draft depending upon operating conditions is established. A heating model of one meter diameter has been built in a thermal similitude. The turbulence rate has been measured with a hot wire anemometer at the tower exit and visualizations have also been made. Natural draft stability has been studied by these means for four different shell shapes and a wide range of operating conditions. Experimental and theoretical results agree satisfactorily and experiments can be considered as a validation of theory

  15. Tower Mesonetwork Climatology and Interactive Display Tool

    Science.gov (United States)

    Case, Jonathan L.; Bauman, William H., III

    2004-01-01

    Forecasters at the 45th Weather Squadron and Spaceflight Meteorology Group use data from the tower network over the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) to evaluate Launch Commit Criteria, and issue and verify forecasts for ground operations. Systematic biases in these parameters could adversely affect an analysis, forecast, or verification. Also, substantial geographical variations in temperature and wind speed can occur under specific wind directions. To address these concerns, the Applied Meteorology Unit (AMU) developed a climatology of temperatures and winds from the tower network, and identified the geographical variation and significant tower biases. The mesoclimate is largely driven by the complex land-water interfaces across KSC/CCAFS. Towers with close proximity to water typically had much warmer nocturnal temperatures and higher wind speeds throughout the year. The strongest nocturnal wind speeds occurred from October to March whereas the strongest mean daytime wind speeds occurred from February to May. These results of this project can be viewed by forecasters through an interactive graphical user interface developed by the AMU. The web-based interface includes graphical and map displays of mean, standard deviation, bias, and data availability for any combination of towers, variables, months, hours, and wind directions.

  16. Structure of natural draft cooling towers, 1

    International Nuclear Information System (INIS)

    Ishioka, Hitoshi; Sakamoto, Yukichi; Tsurusaki, Mamoru; Koshizawa, Koichi; Chiba, Toshio

    1976-01-01

    Thousands of natural draft cooling towers have been utilized, in Europe and America, as cooling systems of power plants or as countermeasures against thermal polution. Recently in Japan, demands for cooling tower systems have been increasing remarkably with the construction of large power plants and the legislation of environmental regulations. In view of the severe natural conditions in Japan such as strong wind and seismic loadings, etc., the establishment of the optimum design and construction method is essential for the building of safe and economical towers. In order to establish a comprehensive plan of a power plant cooling system of the appropriate structural type, the authors have made researches and experiments on design conditions, static and dynamic analyses, and comparative studies of various structural types such as reinforced concrete thin-shell structures, steel framed structures and composite shell segment structures, based on the investigation results of towers in Europe and America. These results are presented in three reports, the 1st of which concerns cooling tower shells as are hereinafter described. (auth.)

  17. Ocean bottom seismometer technology

    Science.gov (United States)

    Prothero, William A., Jr.

    Seismometers have been placed on the ocean bottom for about 45 years, beginning with the work of Ewing and Vine [1938], and their current use to measure signals from earthquakes and explosions constitutes an important research method for seismological studies. Approximately 20 research groups are active in the United Kingdom, France, West Germany, Japan, Canada, and the United States. A review of ocean bottom seismometer (OBS) instrument characteristics and OBS scientific studies may be found in Whitmarsh and Lilwall [1984]. OBS instrumentation is also important for land seismology. The recording systems that have been developed have been generally more sophisticated than those available for land use, and several modern land seismic recording systems are based on OBS recording system designs.The instrumentation developed for OBS work was the topic of a meeting held at the University of California, Santa Barbara, in July 1982. This article will discuss the state of the art of OBS Technology, some of the problems remaining to be solved, and some of the solutions proposed and implemented by OBS scientists and engineers. It is not intended as a comprehensive review of existing instrumentation.

  18. Update on the Purdue University 2-second Drop Tower

    Science.gov (United States)

    Collicott, Steven

    A small drop tower of approximately one second drop duration was built in the School of Aero-nautics and Astronautics at Purdue University beginning in 1998 and operated until summer 2007. This inexpensive tower in an old airplane hanger, was built largely by Yongkang Chen, now a Research Professor at Portland State University in Oregon, USA. In about 7 years of operations, the tower generated sufficient science results for Chen's PhD thesis[1] (summarized in three AIAA Journal papers[2-4]), Fitzpatrick's MS thesis[5], two industry projects for since-canceled advanced rodent habitats for ISS, and one project for NASA Marshall. In addition to the science use, Purdue undergraduate students designed, built, and performed simpler fluids experiments for their own career advancement, including a novel investigation of the impact of imperfect repeatability of initial conditions on a zero-g fluids experiment. The tower was also used for outreach to school children. It is most satisfying that Chen's PhD research in this small tower, and subsequent discussions and interactions, helped Weislogel to propose the two Vane Gap tests in his highly successful Capillary Fluids Experiment (CFE) in the International Space Station in 2006 and 2007[6]. Chen as been involved in the remodeling of these two Vane Gap cylinders for subsequent re-launch to ISS for a second round of experiments expected in 2010 and 2011. In August 2007 the School of Aeronautics and Astronautics at Purdue University moved into the new Neil Armstrong Hall of Engineering and construction on a new 2-second drop tower began. A vertical shaft of nearly 23 meters was designed into the building. An approximately 80 m2 general-use fluids lab is at the top level, and a small access room of approximately 9 m2 is at the bottom. However, construction of the new $57M building created only the space for the science facility, not the science facility itself. The science facility is under construction and this paper presents

  19. Cooling towers and legionella; Koeltorens en legionella

    Energy Technology Data Exchange (ETDEWEB)

    Schalekamp, J.D. [Afdeling Medische Milieukunde, Gemeentelijke Gezondheidsdienst voor Rotterdam en omstreken, Rotterdam (Netherlands)

    2003-03-01

    A brief description is given of the principle of cooling towers, the prevention of legionella in cooling towers, and related regulations. Also the intermediate results of a survey on open cooling towers in the Rotterdam area are presented. Finally, attention is paid to the procedure to handle cases in which legionella has been detected. [Dutch] Jaarlijks vinden er op de wereld epidemieen van legionellose plaats, veroorzaakt door open koeltorens. in dit artikel wordt achtereenvolgens een korte beschrijving gegeven van het werkingsprincipe van koeltorens; de relatie tussen koeltorenbeheer en legionella in open koeltorens; en de huidige stand van zaken op het gebied van regelgeving. Daarnaast worden tussentijdse resultaten van een in Rotterdam gestarte inventarisatie van open koeltorens gegeven. Tenslotte wordt de procedure uiteengezet van de aanpak bij ziektegevallen waarbij legionellose wordt geconstateerd.

  20. Operating manual for the Tower Shielding Facility

    Energy Technology Data Exchange (ETDEWEB)

    1985-12-01

    This manual provides information necessary to operate and perform maintenance on the reactor systems and all equipment or systems which can affect their operation or the safety of personnel at the Tower Shielding Facility. The first four chapters consist of introductory and descriptive material of benefit to personnel in training, the qualifications required for training, the responsibilities of the personnel in the organization, and the procedures for reviewing proposed experiments. Chapter 8, Emergency Procedures, is also a necessary part of the indoctrination of personnel. The procedures for operation of the Tower Shielding Reactor (TSR-II), its water cooling system, and the main tower hoists are outlined in Chapters 5, 6, and 7. The Technical Specification surveillance requirements for the TSR-II are summarized in Chapter 9. The maintenance and calibration schedule is spelled out in Chapter 10. The procedures for assembly and disassembly of the TSR-II are outlined in Chapter 11.

  1. Damping of wind turbine tower vibrations

    DEFF Research Database (Denmark)

    Brodersen, Mark Laier; Pedersen, Mikkel Melters

    Damping of wind turbine vibrations by supplemental dampers is a key ingredient for the continuous use of monopiles as support for offshore wind turbines. The present thesis consists of an extended summary with four parts and appended papers [P1-P4] concerning novel strategies for damping of tower...... in a stroke amplifying brace, which amplifies the displacement across the damper and thus reduces the desired level of damper force. For optimal damping of the two lowest tower modes, a novel toggle-brace concept for amplifying the bending deformation of the tower is presented. Numerical examples illustrate...... damper with IFFis validated by a series of real time hybrid simulations (RTHS). The experimental results illustrate the ability of the hybrid damper concept to increase damper stroke or attainable damping. The results also show that the actuator signal is quitesensitive to drift due an offset...

  2. Operating manual for the Tower Shielding Facility

    International Nuclear Information System (INIS)

    1985-12-01

    This manual provides information necessary to operate and perform maintenance on the reactor systems and all equipment or systems which can affect their operation or the safety of personnel at the Tower Shielding Facility. The first four chapters consist of introductory and descriptive material of benefit to personnel in training, the qualifications required for training, the responsibilities of the personnel in the organization, and the procedures for reviewing proposed experiments. Chapter 8, Emergency Procedures, is also a necessary part of the indoctrination of personnel. The procedures for operation of the Tower Shielding Reactor (TSR-II), its water cooling system, and the main tower hoists are outlined in Chapters 5, 6, and 7. The Technical Specification surveillance requirements for the TSR-II are summarized in Chapter 9. The maintenance and calibration schedule is spelled out in Chapter 10. The procedures for assembly and disassembly of the TSR-II are outlined in Chapter 11

  3. Engineering photochemical smog through convection towers

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, S.; Prueitt, M.L.; Bossert, J.E.; Mroz, E.J.; Krakowski, R.A.; Miller, R.L. [Los Alamos National Lab., NM (United States); Jacobson, M.Z.; Turco, R.P. [Los Alamos National Lab., NM (United States)]|[Univ. of California, Los Angeles, CA (United States). Atmospheric Sciences Dept.

    1995-02-01

    Reverse convection towers have attracted attention as a medium for cleansing modern cities. Evaporation of an aqueous mist injected at the tower opening could generate electrical power by creating descent, and simultaneously scavenge unsightly and unhealthful particulates. The study offered here assesses the influence to tower water droplets on the photochemical component of Los Angeles type smog. The primary radical chain initiator OH is likely removed into aqueous phases well within the residence time of air in the tower, and then reacts away rapidly. Organics do not dissolve, but nighttime hydrolysis of N{sub 2}O{sub 5} depletes the nitrogen oxides. A lack of HOx would slow hydrocarbon oxidation and so also ozone production. Lowering of NOx would also alter ozone production rates, but the direction is uncertain. SO{sub 2} is available in sufficient quantities in some urban areas to react with stable oxidants, and if seawater were the source of the mist, the high pH would lead to fast sulfur oxidation kinetics. With an accommodation coefficient of 10{sup {minus}3}, however, ozone may not enter the aqueous phase efficiently. Even if ozone is destroyed or its production suppressed, photochemical recovery times are on the order of hours, so that tower processing must be centered on a narrow midday time window. The cost of building the number of structures necessary for this brief turnover could be prohibitive. The increase in humidity accompanying mist evaporation could be controlled with condensers, but might otherwise counteract visibility enhancements by recreating aqueous aerosols. Quantification of the divergent forcings convection towers must exert upon the cityscape would call for coupled three dimensional modeling of transport, microphysics, and photochemistry. 112 refs.

  4. Dolmen and Tower Tombs (3600 - 2000 BC)

    OpenAIRE

    Steimer-Herbet, Tara

    2014-01-01

    In the proto-historic period, the territory of contemporary Jordan was covered with megalithic tombs of two types that correspond to different livelihoods, associated with more or less arid environments. Thus, sedentary settlements developed dolmen necropolises, while the steppe was covered with tower tombs. Figure II.15 — Tower Tombs and Dolmens in Ancient Bronze Time. In Jordan, the construction of megalithic tombs began in the early 4th millennium BC and faded at the turn of the 2nd mille...

  5. Control Towers in Supply Chain Management - Past and Future

    Directory of Open Access Journals (Sweden)

    Anna Trzuskawska-Grzesińska

    2017-02-01

    Full Text Available The global economy requires global supply chain management which relies on visibility and responsiveness. Determinants such as: information technology tools, process knowledge, sales and operations planning experiences, etc., enable the formation of theory and practice for the supply chain control tower concept. The goal of the research paper is to identify business examples of different approaches to the supply chain control tower in the past and initiate a discussion on their future. This paper synthesizes past control tower practices and identifies possible future trends. The author performed: literature analysis, three selected companies' case studies and comparative analyses. As the control towers evolve, while supply chains are transforming continuous, update from the market is needed. The research findings showed the selected companies, in the future, perceived control tower's activities as a potential source of revenue not just solely a source of cost and time optimization as well as a source of value added to customer. The researched control towers were built and still they are developed. The business frequently changes and requires control towers to be adjusted, reengineered and adaptive. The researched control towers are needed to keep control over supply chain while it is transforming. There is a differentiation between the supply chain control towers, logistic services control towers and reverse supply chain control towers. An integration mechanism between the control towers would be necessary to assure entire supply chain visibility and orchestration. The research also shows the knowledge gap regarding the control towers in supply chain, specially their possible configurations and future.

  6. Long-term behaviour of towers & fabric structures. The bell tower of Monza cathedral

    Directory of Open Access Journals (Sweden)

    Luigia Binda

    2010-12-01

    Full Text Available After the collapse of some heavy buildings and towers in Italy and elsewhere, the hypothesis of possible continuous damage to these structures due to the dead and cyclic loads (wind, temperature variations, etc. has been formulated by the authors. The long term behaviour of historic masonry has also been detected by laboratory creep and cyclic tests. The results indicate that a laboratory and on site investigation together with analytical modelling are important peculiarly for tall bell-towers. The application of these procedures on the Bell-Tower of the Cathedral of Monza is here reported and discussed.

  7. Influence of apparent wave velocity on seismic performance of a super-long-span triple-tower suspension bridge

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2015-06-01

    Full Text Available As one of the main characteristics of seismic waves, apparent wave velocity has great influence on seismic responses of long-span suspension bridges. Understanding these influences is important for seismic design. In this article, the critical issues concerning the traveling wave effect analysis are first reviewed. Taizhou Bridge, the longest triple-tower suspension bridge in the world, is then taken as an example for this investigation. A three-dimensional finite element model of the bridge is established in ABAQUS, and the LANCZOS eigenvalue solver is employed to calculate the structural dynamic characteristics. Traveling wave effect on seismic responses of these long-span triple-tower suspension bridges is investigated. Envelopes of seismic shear force and moment in the longitudinal direction along the three towers, relative displacements between the towers and the girder, and reaction forces at the bottoms of the three towers under different apparent wave velocities are calculated and presented in detail. The results show that the effect of apparent wave velocity on the seismic responses of triple-tower suspension bridge fluctuates when the velocity is lower than 2000 m/s, and the effects turn stable when the velocity becomes larger. In addition, the effects of traveling wave are closely related to spectral characteristics and propagation direction of the seismic wave, and seismic responses of components closer to the source are relatively larger. Therefore, reliable estimation of the seismic input and apparent wave velocity according to the characteristics of the bridge site are significant for accurate prediction of seismic responses. This study provides critical reference for seismic analysis and design of long-span triple-tower suspension bridges.

  8. Lifting system and apparatus for constructing wind turbine towers

    Science.gov (United States)

    Livingston, Tracy; Schrader, Terry; Goldhardt, James; Lott, James

    2011-02-01

    The disclosed invention is utilized for mounting a wind turbine and blade assembly on the upper end of a wind turbine tower. The invention generally includes a frame or truss that is pivotally secured to the top bay assembly of the tower. A transverse beam is connected to the frame or truss and extends fore of the tower when the frame or truss is in a first position and generally above the tower when in a second position. When in the first position, a wind turbine or blade assembly can be hoisted to the top of the tower. The wind turbine or blade assembly is then moved into position for mounting to the tower as the frame or truss is pivoted to a second position. When the turbine and blade assembly are secured to the tower, the frame or truss is disconnected from the tower and lowered to the ground.

  9. Low-cost Triangular Lattice Towers for Small Wind Turbines

    Science.gov (United States)

    Adhikari, Ram Chandra

    This thesis focuses on the study of low-cost steel and bamboo triangular lattice towers for small wind turbines. The core objective is to determine the material properties of bamboo and assess the feasibility of bamboo towers. Using the experimentally determined buckling resistance, elastic modulus, and Poisson's ratio, a 12 m high triangular lattice tower for a 500W wind turbine has been modeled as a tripod to formulate the analytical solutions for the stresses and tower deflections, which enables design of the tower based on buckling strength of tower legs. The tripod formulation combines the imposed loads, the base distance between the legs and tower height, and cross-sectional dimensions of the tower legs. The tripod model was used as a reference for the initial design of the bamboo tower and extended to finite element analysis. A 12 m high steel lattice tower was also designed for the same turbine to serve as a comparison to the bamboo tower. The primary result of this work indicates that bamboo is a valid structural material. The commercial software package ANSYS APDL was used to carry out the tower analysis, evaluate the validity of the tripod model, and extend the analysis for the tower design. For this purpose, a 12 m high steel lattice tower for a 500 W wind turbine was examined. Comparison of finite element analysis and analytical solution has shown that tripod model can be accurately used in the design of lattice towers. The tower designs were based on the loads and safety requirements of international standard for small wind turbine safety, IEC 61400-2. For connecting the bamboo sections in the lattice tower, a steel-bamboo adhesive joint combined with conventional lashing has been proposed. Also, considering the low durability of bamboo, periodic replacement of tower members has been proposed. The result of this study has established that bamboo could be used to construct cost-effective and lightweight lattice towers for wind turbines of 500 Watt

  10. The Exact Limit of Some Cubic Towers

    DEFF Research Database (Denmark)

    Anbar Meidl, Nurdagül; Beelen, Peter; Nguyen, Nhut

    2017-01-01

    Recently, a new explicit tower of function fields was introduced by Bassa, Beelen, Garcia and Stichtenoth (BBGS). This resulted in currently the best known lower bound for Ihara’s constant in the case of non-prime finite fields. In particular over cubic fields, the tower’s limit is at least as good...

  11. The Tower of Hanoi and Inductive Logic

    Science.gov (United States)

    Merrotsy, Peter

    2015-01-01

    In the "Australian Curriculum," the concept of mathematical induction is first met in the senior secondary subject Specialist Mathematics. This article details an example, the Tower of Hanoi problem, which provides an enactive introduction to the inductive process before moving to more abstract and cognitively demanding representations.…

  12. Frost protection for atmospheric cooling tower

    International Nuclear Information System (INIS)

    Legrand, G.

    1987-01-01

    When the atmospheric temperature is near or lower than zero it is necessary to reduce the air flow entering in a cooling tower. A wire netting mounted on the air inlet is sprinkled with cold water. The level of the ice curtain and consequently the air flow is regulated by aspersion by hot water [fr

  13. X-ray Observations at Gaisberg Tower

    Directory of Open Access Journals (Sweden)

    Pasan Hettiarachchi

    2018-01-01

    Full Text Available We report the occurrence of X-rays at ground level due to cloud-to-ground flashes of upward-initiated lightning from Gaisberg Tower, in Austria, which is located at an altitude of 1300 m. This is the first observation of X-ray emissions from upward lightning from a tower top located at high altitude. Measurements were carried out using scintillation detectors installed close to the tower top in two phases from 2011 to 2015. X-rays were recorded in three subsequent strokes of three flashes out of the total of 108 flashes recorded in the system during both phases. In contrast to the observations from downward natural or triggered lightning, X-rays were observed only within 10 µs before the subsequent return stroke. This shows that X-rays were emitted when the dart leader was in the vicinity of the tower top, hence during the most intense phase of the dart leader. Both the detected energy and the fluence of X-rays are far lower compared to X-rays from downward natural or rocket-triggered lightning. In addition to the above 108 flashes, an interesting observation of X-rays produced by a nearby downward flash is also presented. The shorter length of dart-leader channels in Gaisberg is suggested as a possible cause of this apparently weaker X-ray production.

  14. The Exact Limit of Some Cubic Towers

    DEFF Research Database (Denmark)

    Anbar Meidl, Nurdagül; Beelen, Peter; Nguyen, Nhut

    2017-01-01

    Recently, a new explicit tower of function fields was introduced by Bassa, Beelen, Garcia and Stichtenoth (BBGS). This resulted in currently the best known lower bound for Ihara’s constant in the case of non-prime finite fields. In particular over cubic fields, the tower’s limit is at least as go...

  15. Tall tower or mountain top measurements?

    Science.gov (United States)

    Bamberger, Ines; Eugster, Werner; Oney, Brian; Brunner, Dominik; Leuenberger, Markus; Schanda, Rüdiger; Henne, Stephan; Buchmann, Nina

    2014-05-01

    Resolving the regional transport and distribution of greenhouse gases in the troposphere is a key topic that challenges both modelers and experimentalists. A dense network of measurement stations would be required, in particular including measurements at high elevation to better represent the entire lower troposphere, and not only small-scale local conditions in the near-surface atmosphere. While this can be achieved by tall towers, also mountain top stations (e.g. Schauinsland, Brocken) and other stations at high elevation (e.g., Mouna Loa, Jungfraujoch) are often appropriate, due to their extended concentration footprint. However, especially over complex, mountainous terrain, the transport of atmospheric gases and their spatio-temporal distribution is difficult to predict due to the development of thermally induced local wind patterns and boundary layer processes. Therefore, the main goal of our study is to test to what extend boundary layer processes at the surface and local wind patterns close to the ground at a mountain top site influence the ambient greenhouse gas patterns compared to measurements taken at a similar altitude but at a tall tower site. To this end we use measurements from the Zugerberg mountain top station, located at a pre-Alpine mountain ridge (987 m a.s.l., 4 m above ground) exposed to the prevailing synoptic winds in Switzerland, and compare these measurements with a neighboring tall tower site (Beromünster radio broadcast tower with its top at 1014 m a.s.l., 217 m above local ground level, and ≡500 m above the Swiss Plateau). The Beromünster tall tower is located at a distance of only 30 km from the mountain top station as the bird flies, and hence a direct comparison minimizes confounding factors that are not related to the tall tower vs. mountain top position of the measurements. Both stations are part of the CarboCount CH greenhouse gas observation network (http://www.carbocount.ch) initiated for long-term monitoring and modeling of

  16. Measurement of NOx fluxes from a tall tower in Beijing

    Science.gov (United States)

    Squires, Freya; Dunmore, Rachel; Lewis, Alastair; Vaughan, Adam; Mullinger, Neil; Nemitz, Eiko; Wild, Oliver; Zhang, Qiang; Hamilton, Jacqueline; Lee, James; Fu, Pingqing

    2017-04-01

    Nitrogen Oxides (NOx, the sum of nitrogen monoxide (NO) and nitrogen dioxide (NO2)) are significant anthropogenic pollutants emitted from most combustion processes. NOx is a precursor species to the formation of O3 and secondary aerosols and, in high concentrations, NO2 can have adverse effects on human health through action as a respiratory irritant. For these reasons, there has been increased focus on improving NOx emissions inventories, typically developed using 'bottom-up' estimates of emissions from their sources, which are used to predict current and future air quality and to guide abatement strategy. Recent studies have shown a discrepancy between NOx inventories and measured NOx emissions for UK cities, highlighting the limitations of bottom-up emissions inventories and the importance of accurate measurement data to improve the estimates. Similarly, inventories in China are associated with large uncertainties and are rapidly changing with time in response to economic development and new environmental regulation. Here, we present data collected as part of the Air Pollutants in Beijing (AIRPOLL-Beijing) campaign from an urban site located at the Institute of Atmospheric Physics, Chinese Academy of Sciences (IAP, CAS) (39˚ 58'28"N, 116˚ 22'16"E) in central Beijing. NOx concentrations were measured using a state-of-the-art chemiluminescence instrument, sampling from an inlet at 100 metres on a meteorological tower. Measurements at 5 Hz coupled with wind vector data measured by a sonic anemometer located at the same height as the inlet allowed NOx emission fluxes to be calculated using the eddy covariance method. Measurements were made during the period 11/11/2016 - 10/12/2016 and compared to existing emission estimates from The Multi-resolution Emission Inventory for China (MEIC) inventory. It is anticipated that this work will be used to evaluate the accuracy of emissions inventories for Beijing, to develop improved emissions estimates and thus provide

  17. The Drop Tower Bremen -Experiment Operation

    Science.gov (United States)

    Könemann, Thorben; von Kampen, Peter; Rath, Hans J.

    The idea behind the drop tower facility of the Center of Applied Space Technology and Micro-gravity (ZARM) in Bremen is to provide an inimitable technical opportunity of a daily access to short-term weightlessness on earth. In this way ZARM`s european unique ground-based microgravity laboratory displays an excellent economic alternative for research in space-related conditions at low costs comparable to orbital platforms. Many national and international ex-perimentalists motivated by these prospects decide to benefit from the high-quality and easy accessible microgravity environment only provided by the Drop Tower Bremen. Corresponding experiments in reduced gravity could open new perspectives of investigation methods and give scientists an impressive potential for a future technology and multidisciplinary applications on different research fields like Fundamental Physics, Astrophysics, Fluid Dynamics, Combus-tion, Material Science, Chemistry and Biology. Generally, realizing microgravity experiments at ZARM`s drop tower facility meet new requirements of the experimental hardware and may lead to some technical constraints in the setups. In any case the ZARM Drop Tower Operation and Service Company (ZARM FAB mbH) maintaining the drop tower facility is prepared to as-sist experimentalists by offering own air-conditioned laboratories, clean rooms, workshops and consulting engineers, as well as scientific personal. Furthermore, ZARM`s on-site apartment can be used for accommodations during the experiment campaigns. In terms of approaching drop tower experimenting, consulting of experimentalists is mandatory to successfully accomplish the pursued drop or catapult capsule experiment. For this purpose there will be a lot of expertise and help given by ZARM FAB mbH in strong cooperation to-gether with the experimentalists. However, in comparison to standard laboratory setups the drop or catapult capsule setup seems to be completely different at first view. While defining a

  18. Ozonation system for treatment of cooling tower water

    Energy Technology Data Exchange (ETDEWEB)

    Coakley, T.; Horton, A.; Kaplan, B.

    1994-11-10

    An improved system for treatment of cooling tower water using ozone as a biocide. A self-contained unit is supplied with compressed air which is introduced to ozone generating electrodes at a constant flowrate. The ozone is mixed with tower water and then returned to the cooling tower. A sampling probe allows for constant monitoring of the ozone content of water coming from the tower. The volume of ozone mixing with the tower water is accordingly constantly adjusted. The system also includes safety control features to monitor system operation and provide shutoff in the event of malfunction. (author).

  19. An automatic and effective approach in identifying tower cranes

    Science.gov (United States)

    Yu, Bo; Niu, Zheng; Wang, Li; Liu, Yaqi

    2012-04-01

    A method which can distinguish tower cranes from other objects in an image is proposed in this paper. It synthesizes the advantages of both morphological theory and geometrical characters to identify tower cranes accurately. The algorithm uses morphological theory to remove noise and segment images. Moreover, geometrical characters are adopted to extract tower cranes with thresholds. To test the algorithm's practical applicability, we apply it to another image to check the result. The experiments show that the approach can locate the position of tower cranes precisely and calculate the number of cranes at 100% accuracy rate. It can be applied to identifying tower cranes in small regions.

  20. Radio Transmitters and Tower Locations, Layer includes all towers identified visually and include cellular and other communication towers., Published in 2008, 1:1200 (1in=100ft) scale, Noble County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Radio Transmitters and Tower Locations dataset current as of 2008. Layer includes all towers identified visually and include cellular and other communication towers..

  1. Study on Tower Models for EHV Transmission Line

    Directory of Open Access Journals (Sweden)

    Xu Bao-Qing

    2016-01-01

    Full Text Available Lightning outage accident is one of the main factors that threat seriously the safe and reliable operation of power system. So it is very important to establish reasonable transmission tower model and evaluate the impulse response characteristic of lightning wave traveling on the transmission tower properly for determining reliable lightning protection performance. With the help of Electromagnetic Transient Program (EMTP, six 500kV tower models are built. Aiming at one line to one transformer operating mode of 500kV substation, the intruding wave overvoltage under different tower models is calculated. The effect of tower model on intruding overvoltage has been studied. The results show that different tower models can result in great differences to the calculation results. Hence, reasonable selection of the tower model in the calculation of back- strike intruding wave is very important.

  2. Restoration of the Serranos Towers in Valencia.

    Directory of Open Access Journals (Sweden)

    Camilla Mileto

    2003-12-01

    Full Text Available The recent restoration of the emblematic Serranos Towers carried out by an interdisciplinary team of specialists was an excuse to delve into the history and masonry of the towers, from their initial building and use as a prison to the restorations works practised in the 19th century and subsequent repairs. The cleaning of the walls permitted a direct study of the masonry, which provided a great deal of information that complemented the rigorous historical investigation. The maintenance scheme planned for the future is an interesting proposal, where good sense prevails over improvisation, so often a reality in the restoration of monuments today.

  3. Optical study of solar tower power plants

    International Nuclear Information System (INIS)

    Eddhibi, F; Amara, M Ben; Balghouthi, M; Guizani, A

    2015-01-01

    The central receiver technology for electricity generation consists of concentrating solar radiation coming from the solar tracker field into a central receiver surface located on the top of the tower. The heliostat field is constituted of a big number of reflective mirrors; each heliostat tracks the sun individually and reflects the sunlight to a focal point. Therefore, the heliostat should be positioned with high precision in order to minimize optical losses. In the current work, a mathematical model for the analysis of the optical efficiency of solar tower field power plant is proposed. The impact of the different factors which influence the optical efficiency is analyzed. These parameters are mainly, the shading and blocking losses, the cosine effect, the atmospheric attenuation and the spillage losses. A new method for the calculation of blocking and shadowing efficiency is introduced and validated by open literature

  4. Side Stream Filtration for Cooling Towers

    Energy Technology Data Exchange (ETDEWEB)

    None

    2012-10-20

    This technology evaluation assesses side stream filtration options for cooling towers, with an objective to assess key attributes that optimize energy and water savings along with providing information on specific technology and implementation options. This information can be used to assist Federal sites to determine which options may be most appropriate for their applications. This evaluation provides an overview of the characterization of side stream filtration technology, describes typical applications, and details specific types of filtration technology.

  5. Solar tower and farming plants compared

    International Nuclear Information System (INIS)

    Meinecke, W.; Becker, M.; Klaiss, H.

    1991-01-01

    The article gives an abbreviated version of a study under the guidance of the DLR, comparing solar tower and farming plants (channel collectors) for electricity generation, in respect of technical and economical aspects. The comparison considers various influencing factors such as for instance: Meteorological conditions, characteristic technical differences, unit size, and permits conclusions, which are important for the development and construction of future plants. (orig.) [de

  6. INTEGRATED TWIN TOWERS DAN ISLAMISASI ILMU

    Directory of Open Access Journals (Sweden)

    Syaifuddin Syaifuddin

    2013-05-01

    Full Text Available This paper shows some idea as follows: First, integrated design of the Twin Towers as the changing action from IAIN to UIN Sunan Ampel. The religion and general knowledge’s position of Twin Towers’ integrated design is not mixed into one, but it works individually, and at the certain time are united in mutual dialogue. Second, Islamize design is done in order to criticize the general knowledge which has western sources and are secular, materialistic, and individualistic. In the process to Islamize the knowledge, Islamic knowledge tries to intervene the general knowledge in order to filter it so the knowledge will be Islamized. Consequently, to Islamize knowledge is to give an Islamic concept into general knowledge. Third, there are the similarities and differences between integrated design knowledge based on Islamic knowledge and integrated Twin Towers. The difference is in its epistemology process. The similarity is in the curriculum (ontology and objective (axiology. In the curriculum, the examined knowledge is religion and general knowledge. While the objective, Islamize knowledge and integrated Twin Towers aims to integrate religion and general knowledge, to dialogue, to communicate, and to synergy, so it can be a knowledge which is intact-integral-integrative.

  7. Modeling of Direct Contact Wet Cooling Tower in ETRR-2

    International Nuclear Information System (INIS)

    El Khatib, H.H.; Ismail, A.L.; ElRefaie, M.E.

    2008-01-01

    The Egyptian Testing and Research Reactor no.2 (ETRR-2) was commissioned at 1997 with maximum power 22 MW for research purposes; an induced draft wet cooling tower (counter flow type) was putted in operation in 2003 instead of the first one. Investigations are achieved to evaluate cooling tower performance to guarantee that the cooling tower capable to dissipate heat generated in reactor core. Merkel and Poppe analysis was applied to simulate this cooling tower packing. Merkel analysis was applied to predict water outlet temperature from cooling tower and also to show the effect of ambient conditions on this temperature. Poppe analysis was applied to predict Merkel number which evaluate cooling tower. The Runge-Kutta numerical method was applied to solve the differential equations in this model and an engineering equation solver (EES) is the language used to model the cooling tower. This research illustrates that the cooling tower achieves good performance in various sever ambient condition at maximum operating condition of reactor power. The results show that at severe summer condition of wet bulb temperature equals 24 degree c and tower inlet temperature equals 37 degree c, the outlet water temperature equals 30.4 degree c from cooling tower, while the Merkel number is be found 1.253

  8. Analysis of Ideal Towers for Tall Wind Applications: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Dykes, Katherine L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Damiani, Rick R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Roberts, Joseph O [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lantz, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-02-27

    Innovation in wind turbine tower design is of significant interest for future development of wind power plants. First, wind turbine towers account for a large portion of overall capital expenditures for wind power projects. Second, for low wind-resource regions of the world, the use of low-cost tall-tower technology has the potential to open new markets for development. This study investigates the relative potential of various tower configurations in terms of mass and cost. For different market applications and hub heights, idealized tall towers are designed and compared. The results show that innovation in wind turbine controls makes reaching higher hub heights with current technology economically viable. At the same time, new technologies hold promise for reducing tower costs as these technologies mature and hub heights reach twice the current average.

  9. Optimal Electrostatic Space Tower (Mast, New Space Elevator)

    OpenAIRE

    Bolonkin, Alexander

    2007-01-01

    Author offers and researched the new and revolutionary inflatable electrostatic AB space towers (mast, new space elevator) up to one hundred twenty thousands kilometers (or more) in height. The main innovation is filling the tower by electron gas, which can create pressure up one atmosphere, has negligible small weight and surprising properties. The suggested mast has following advantages in comparison with conventional space elevator: 1. Electrostatic AB tower may be built from Earth surface...

  10. Review of New Concepts, Ideas and Innovations in Space Towers

    OpenAIRE

    Krinker, Mark

    2010-01-01

    Under Space Tower the author understands structures having height from 100 km to the geosynchronous orbit and supported by surface of Earths. The classical Space Elevator is not included in space towers. That has three main identifiers which distingue from Space Tower: Space Elevator has part over Geosynchronous Orbit (GSO) and all installation supported only the centrifugal force of Earth, immobile cable connected to surface of Earth, no pressure on the surface. A lot of new concepts, ideas ...

  11. Isolation of Legionella pneumophila from hospital cooling towers.

    Science.gov (United States)

    Nadarajah, M; Goh, K T

    1986-01-01

    Water from twenty cooling towers from three major hospitals (A, B, C) were screened for the presence of Legionella pneumophila. Three of the water specimens were found to be positive for the organism. Serogroup 1 was isolated from the two cooling towers in Hospital A, while serogroup 4 was isolated from one of the cooling towers in Hospital B, this being the first time L. pneumophila has been isolated in Singapore.

  12. Technical Evaluation of Side Stream Filtration for Cooling Towers

    Energy Technology Data Exchange (ETDEWEB)

    None

    2012-10-01

    Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. Cooling towers represent the point in a cooling system where heat is dissipated to the atmosphere through evaporation. Cooling towers are commonly used in industrial applications and in large commercial buildings to release waste heat extracted from a process or building system through evaporation of water.

  13. Radiation scanning aids tower diagnosis at Arun LNG plant

    International Nuclear Information System (INIS)

    Naklie, M.M.; Pless, L.; Gurning, T.P.; Hyasak, M.

    1990-01-01

    Radiation scanning has been used effectively to troubleshoot the treating towers of the Arun LNG plant in Sumatra, Indonesia. The plant is one of the world's largest such facilities. The analysis was part of an investigation aimed at increasing the capacity of the treater section of the plant. Radiation scanning is a tool which, in addition to tower differential pressure and product purity, can aid in diagnosing tower performance

  14. Transmission Tower Environment Monitoring Using UAV

    International Nuclear Information System (INIS)

    Redzuwan, Redia Mohd; Din, Norashidah Md; Baharuddin, Mohd Zafri; Mustafa, Intan Shafinaz; Omar, Rohayu Che'

    2013-01-01

    Power utility engineers used to conduct ground survey to collect topographic data. Therefore, they can get detailed and accurate information, but these techniques take a lot of labors and expenses, and spending times for the surveying. An attractive solution to the ground survey is using images taken using Unmanned Aerial Vehicle (UAV). Images captured from UAV can be collected quickly and efficiently over the same area covered in the land survey, in a fraction of the time. The purpose of this research is to mosaic the large numbers of spectral images together into a region wide panoramic image which allows experts to analyze the data for transmission tower monitoring purposes.

  15. Pressing technology for large bottoms

    International Nuclear Information System (INIS)

    Jilek, L.

    1986-01-01

    The technology has been selected of a circular plate bent into the shape of a trough, for pressing bottoms of pressure vessels from a circular plate of large diameter. The initial sheet is first bent in the middle by heating with the edges remaining straight. These are then welded longitudinally by electroslag welding and the circular shape is flame cut. The result will be a plate with a straight surface in the middle with raised edges which may be pressed into the desired shape. In this manner it is also possible to press pressure vessel bottoms with tube couplings from plates which are thickened in the middle and drilled; additional welding is then eliminated. Deformation from heat treatment may be avoided by the use of a fixture in the shape of a ring with a groove into which is fixed the edge of the bottom. During hardening of the bottom it will be necessary to care for the withdrawal of vapours and gases which would hamper uniform cooling. Bottom hardening with the grill and the cupola downwards has been proven. Deformation which occurs during treatment may to a certain extent be removed by calibration which cannot, however, be made without special fixtures and instruments. (J.B.)

  16. GPM GROUND VALIDATION METEOROLOGICAL TOWER ENVIRONMENT CANADA GCPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Meteorological Tower Environment Canada GCPEx dataset provides temperature, relative humidity, 10m winds, pressure and solar radiation data...

  17. Improving performance and reducing costs of cooling towers

    International Nuclear Information System (INIS)

    Bartz, J.A.

    1992-01-01

    Cooling towers represent a significant capital investment at a steam electric power station. In addition, deficiencies in thermal performance can result in major operating penalties of fuel cost, replacement energy, and capacity addition. This paper summarizes two recent EPRI research projects aimed at reducing thermal performance deficiencies and decreasing installed costs of evaporative cooling towers. First, EPRI Research Project 2113, Cooling Tower Performance Prediction and Improvement, is summarized. This project has resulted in published data sets on the measured thermal performance characteristics of a variety of cooling tower packings, computer codes to predict tower performance, and computer code validation through large-scale tower performance measurements. Principal results are contained in an EPRIGEMS software module, Cooling Tower Advisor. This PC- based software contains a tutorial plus codes to predict tower thermal performance, arranged in a user-friendly format. The second EPRI effort, Research Project 2819-10/11, Fabric Structures for Power Plant Applications, has resulted in designs and costs of large structures with shells constructed of recently-developed fabrics. Primary power plant applications for such structures are the shells of natural draft cooling towers and coal-pile covers. Fabric structures offer low initial cost, acceptable life, and seismic superiority, among other advantages. Detailed conceptual designs and installed cost data are reviewed. 8 refs., 9 figs., 3 tabs

  18. Newton slopes for Artin-Schreier-Witt towers

    DEFF Research Database (Denmark)

    Davis, Christopher; Wan, Daqing; Xiao, Liang

    2016-01-01

    We fix a monic polynomial f(x)∈Fq[x] over a finite field and consider the Artin-Schreier-Witt tower defined by f(x); this is a tower of curves ⋯→Cm→Cm−1→⋯→C0=A1, with total Galois group Zp. We study the Newton slopes of zeta functions of this tower of curves. This reduces to the study of the Newton...... a result on the behavior of the slopes of the eigencurve associated to the Artin-Schreier-Witt tower, analogous to the result of Buzzard and Kilford....

  19. GPM GROUND VALIDATION METEOROLOGICAL TOWER ENVIRONMENT CANADA GCPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Meteorological Tower Environment Canada GCPEx dataset provides temperature, relative humidity, 10 m winds, pressure and solar radiation...

  20. Measurements at cooling tower plumes. Part 3. Three-dimensional measurements at cooling tower plumes

    International Nuclear Information System (INIS)

    Fortak, H.

    An extended field experiment is described in which cooling tower plumes were studied by means of three-dimensional in situ measurements. The goal was to obtain input data for numerical models of cooling tower plumes. Of special interest were data for testing or developing assumptions for sub-grid parametrizations. Utilizing modern systems for high-resolution aerology and small aircraft, four measuring campaigns were conducted: two campaigns (1974) at the cooling towers of the RWE power station Neurath and also two (1975) at the single cooling tower of the RWE power station Meppen. Because of the broad spectrum of weather situations it can be assumed that the results are representative with regard to the interrelationship between structure of cooling tower plume and large-scale meteorological situation. A large number of flights with a powered glider crossing the plumes on orthogonal tracks was performed. All flights showed that the plume could be identified up to large downwind distances by discontinuous jumps of temperature and vapor pressure. Therefore, a definite geometry of the plume could always be defined. In all cross sections a vertical circulation could be observed. At the boundary, which could be defined by the mentioned jumps of temperature and vapor pressure, a maximum of downward vertical motion could be observed in most cases. Entrainment along the boundary of a cross section seems to be very small, except at the lower part of the plume. There, the mass entrainment is maximum and is responsible for plume rise as well as for enlargement of the cross section. The visible part of the plume (cloud) was only a small fraction of the whole plume. High-resolution aerology is necessary in order to explain the structure and behavior of such plumes. This is especially the case in investigations regarding the dynamic break-through of temperature inversions. Such cases were observed frequently under various meteorological conditions and are described

  1. Submarine tower escape decompression sickness risk estimation.

    Science.gov (United States)

    Loveman, G A M; Seddon, E M; Thacker, J C; Stansfield, M R; Jurd, K M

    2014-01-01

    Actions to enhance survival in a distressed submarine (DISSUB) scenario may be guided in part by knowledge of the likely risk of decompression sickness (DCS) should the crew attempt tower escape. A mathematical model for DCS risk estimation has been calibrated against DCS outcome data from 3,738 exposures of either men or goats to raised pressure. Body mass was used to scale DCS risk. The calibration data included more than 1,000 actual or simulated submarine escape exposures and no exposures with substantial staged decompression. Cases of pulmonary barotrauma were removed from the calibration data. The calibrated model was used to estimate the likelihood of DCS occurrence following submarine escape from the United Kingdom Royal Navy tower escape system. Where internal DISSUB pressure remains at - 0.1 MPa, escape from DISSUB depths 60% DCS risk predicted for a 200-meter escape from saturation at 0.21 MPa. Using the calibrated model to predict DCS for direct ascent from saturation gives similar risk estimates to other published models.

  2. The tower of Hanoi myths and maths

    CERN Document Server

    Hinz, Andreas M; Petr, Ciril

    2018-01-01

    The solitaire game “The Tower of Hanoi" was invented in the 19th century by the French number theorist Édouard Lucas. The book presents its mathematical theory and offers a survey of the historical development from predecessors up to recent research. In addition to long-standing myths, it provides a detailed overview of the essential mathematical facts with complete proofs, and also includes unpublished material, e.g., on some captivating integer sequences. The main objects of research today are the so-called Hanoi graphs and the related Sierpiński graphs. Acknowledging the great popularity of the topic in computer science, algorithms, together with their correctness proofs, form an essential part of the book. In view of the most important practical applications, namely in physics, network theory and cognitive (neuro)psychology, the book also addresses other structures related to the Tower of Hanoi and its variants. The updated second edition includes, for the first time in English, the breakthrough reach...

  3. Bottom reflector for power reactors

    International Nuclear Information System (INIS)

    Elter, C.; Kissel, K.F.; Schoening, J.; Schwiers, H.G.

    1982-01-01

    In pebble bed reactors erosion and damage due fuel elements movement on the surface of the bottom reflector should be minimized. This can be achieved by chamfering and/or rounding the cover edges of the graphite blocks and the edges between the drilled holes and the surface of the graphite block. (orig.) [de

  4. Culture from the Bottom Up

    Science.gov (United States)

    Atkinson, Dwight; Sohn, Jija

    2013-01-01

    The culture concept has been severely criticized for its top-down nature in TESOL, leading arguably to its falling out of favor in the field. But what of the fact that people do "live culturally" (Ingold, 1994)? This article describes a case study of culture from the bottom up--culture as understood and enacted by its individual users.…

  5. Grounding experiments on soft bottoms

    DEFF Research Database (Denmark)

    Sterndorff, M.J.; Pedersen, Preben Terndrup

    1996-01-01

    To verify a theoretical analysis procedure for calculation of the hull girder response of ships running aground, a series of large-scale ship grounding experiments was performed on an artificial island made of engineered fill. The tests were conducted by running a condemned fishing vessel up...... for grounding on soft bottoms....

  6. Limit groups, positive-genus towers and measure equivalence

    OpenAIRE

    Bridson, Martin R; Tweedale, Michael; Wilton, Henry

    2005-01-01

    By definition, an $\\omega$-residually free tower is positive-genus if all surfaces used in its construction are of positive genus. We prove that every limit group is virtually a subgroup of a positive-genus $\\omega$-residually free tower. By combining this with results of Gaboriau, we prove that elementarily free groups are measure equivalent to free groups.

  7. Wind-induced Vibrations in the European Court Towers

    DEFF Research Database (Denmark)

    Hansen, Jannick B.; Brincker, Rune; Andersen, Ken G.

    2012-01-01

    Issues regarding occupancy comfort in vibration-sensitive structures are the motivation of this study concerning windinduced vibrations in the European Court Towers in Luxembourg. In one of the two identical towers tuned liquid dampers (TLD) have been installed. Recent studies investigate the cha...

  8. 47 CFR 5.109 - Antenna and tower requirements.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Antenna and tower requirements. 5.109 Section 5... BROADCAST) Technical Standards and Operating Requirements § 5.109 Antenna and tower requirements. (a) Applicants with fixed stations that use antennas that exceed 6 meters in height above the ground level or...

  9. Trends in the development of ehv ac tower lines

    Energy Technology Data Exchange (ETDEWEB)

    McMurtrie, N.J.

    1966-01-01

    Some of the more important current trends in the development of EHV ac tower lines are outlined. The emphasis is primarily on the design and construction aspects of such items as towers, foundations, conductors, insulators and hardware, and the growing integration of the new designs with construction methods. Particular attention is given to the role played by Canadian utilities, manufacturers and engineers.

  10. Frequency analysis of a tower-cable coupled system

    International Nuclear Information System (INIS)

    Park, Moo Yeol; Kim, Seock Hyun; Park, In Su; Cui, Chengxun

    2013-01-01

    This study considers the prediction of natural frequency to avoid resonance in a wind turbine tower- cable coupled system. An analytical model based on the Rayleigh-Ritz method is proposed to predict the resonance frequency of a wind turbine tower structure supported by four guy cables. To verify the validity of the analytical model, a small tower-cable model is manufactured and tested. The frequency and mode data of the tower model are obtained by modal testing and finite element analysis. The validity of the proposed method is verified through the comparison of the frequency analysis results. Finally, using a parametric study with the analytical model, we identified how the cable tension and cable angle affect the resonance frequency of the wind turbine tower structure. From the analysis results, the tension limit and optimal angle of the cable are identified.

  11. The design and stability determination of wind turbine tower

    International Nuclear Information System (INIS)

    Abas Abd Wahab; Khairul Barriyah

    2001-01-01

    In wind turbine tower design, two load categories (static and wind load) were considered. The static load for this structure is the tower self-weight, which can be calculated from its density and area of the material, whereas the wind load was calculated based on CP3: Chapter V: Part 2: 1972, using the maximum wind speed of 30 m/s. The stability of this tower under the action of these two loads has been determined using RISA-3D program. The program were subjected to two joint types, i.e pinned and fixed joints. The tower using fixed joint members has established the necessary tower stability. The simulation, calculation and results are being discussed in detail in this paper. (Author)

  12. Adaptive Backstepping Control of Lightweight Tower Wind Turbine

    DEFF Research Database (Denmark)

    Galeazzi, Roberto; Borup, Kasper Trolle; Niemann, Hans Henrik

    2015-01-01

    This paper investigates the feasibility of operating a wind turbine with lightweight tower in the full load region exploiting an adaptive nonlinear controller that allows the turbine to dynamically lean against the wind while maintaining nominal power output. The use of lightweight structures...... for towers and foundations would greatly reduce the construction cost of the wind turbine, however extra features ought be included in the control system architecture to avoid tower collapse. An adaptive backstepping collective pitch controller is proposed for tower point tracking control, i.e. to modify...... the angular deflection of the tower with respect to the vertical axis in response to variations in wind speed. The controller is shown to guarantee asymptotic tracking of the reference trajectory. The performance of the control system is evaluated through deterministic and stochastic simulations including...

  13. PORFIDO on the NEMO Phase 2 tower

    Energy Technology Data Exchange (ETDEWEB)

    Ciaffoni, Orlando; Cordelli, Marco; Habel, Roberto; Martini, Agnese; Trasatti, Luciano [INFN-Laboratori Nazionali di Frascati, Via E. Fermi 40, I-00044 Frascati (RM) (Italy)

    2014-11-18

    We have designed and built an underwater measurement system, PORFIDO (Physical Oceanography by RFID Outreach) to gather oceanographic data from the Optical Modules of a neutrino telescope with a minimum of disturbance to the main installation. PORFIDO is composed of a sensor glued to the outside of an Optical Module, in contact with seawater, and of a reader placed inside the sphere, facing the sensor. Data are transmitted to the reader through the glass by RFID and to shore in real time for periods of years. The sensor gathers power from the radio frequency, thus eliminating the need for batteries or connectors through the glass. We have deployed four PORFIDO probes measuring temperatures with the NEMO-KM3Net-Italy Phase 2 tower in april 2013. The four probes are operative and are transmitting temperature data from 3500 m depth.

  14. PORFIDO on the NEMO Phase 2 tower

    International Nuclear Information System (INIS)

    Ciaffoni, Orlando; Cordelli, Marco; Habel, Roberto; Martini, Agnese; Trasatti, Luciano

    2014-01-01

    We have designed and built an underwater measurement system, PORFIDO (Physical Oceanography by RFID Outreach) to gather oceanographic data from the Optical Modules of a neutrino telescope with a minimum of disturbance to the main installation. PORFIDO is composed of a sensor glued to the outside of an Optical Module, in contact with seawater, and of a reader placed inside the sphere, facing the sensor. Data are transmitted to the reader through the glass by RFID and to shore in real time for periods of years. The sensor gathers power from the radio frequency, thus eliminating the need for batteries or connectors through the glass. We have deployed four PORFIDO probes measuring temperatures with the NEMO-KM3Net-Italy Phase 2 tower in april 2013. The four probes are operative and are transmitting temperature data from 3500 m depth

  15. Development of wind turbine towers using fiber reinforced polymers

    Science.gov (United States)

    Ungkurapinan, Nibong

    With an ongoing trend in the wind turbine market, the size of wind turbines has been increasing continuously. Larger wind turbines imply an increase in size, weight, and loads acting on the wind turbine tower. This requires towers to be stronger and stiffer, and consequently leads to bigger tower diameters. Because of their size and weight, transportation and erection require heavy equipment that makes the use of such towers prohibitive in remote communities. To tackle this problem, a research program was initiated at the University of Manitoba to develop the technology required for the fabrication of wind turbine towers constructed of fiber reinforced polymers (FRP) for use in remote communities in Canada. The research program was carried out in stages. During the first stage, a feasibility study and an analytical investigation on various shapes of FRP towers were conducted. The concept of a multi-cellular composite tower was examined in great detail and the finite element results showed that such a tower could result in almost 45 percent reduction in weight. In the second stage of this research program, a robotic filament winding machine was designed and constructed in the Composites Laboratory of the University of Manitoba. It was used to fabricate the multi-cell tower specimens for testing. The third stage of the research program involved the experimental investigation, which was carried out in three phases. In the first phase, two single cell specimens were tested to failure under lateral loading. The specimens were 8 ft (2.44 m) long. The second phase involved the testing of two single cells loaded in compression. The third phase of the experimental investigation involved the testing of two eight-cell jointed tower specimens. The specimens were octagonal and tapered, with a diameter of 21.4 in (543 mm) at the base and 17.4 in (441 mm) at the top. They were 16 ft (4.88 m) in height and tested as cantilever under static loading. Local buckling was the dominant

  16. Asbestos in cooling-tower waters. Final report

    International Nuclear Information System (INIS)

    Lewis, B.A.G.

    1979-03-01

    Water discharges from cooling towers constructed with asbestos fill were found to contain chrysotile--asbestos fibers at concentrations as high as 10 8 fibers/liter. The major source of these fibers, appears to be the components of the towers rather than the air drawn through the towers or the makeup water taken into the towers. Suggested mechanisms for the release of chrysotile fibers from cooling-tower fill include freeze-thaw cycles and dissolution of the cement due to acidic components of the circulating water. Ash- or other material-settling ponds were found to reduce asbestos-fiber concentrations in cooling-tower effluent. The literature reviewed did not support the case for a causal relationship between adverse human health effects and drinking water containing on the order of 10 6 chrysotile--asbestos fibers/liter; for this and other reasons, it is not presently suggested that the use of asbestos fill be discontinued. However, caution and surveillance are dictated by the uncertainties in the epidemiological studies, the absence of evidence for a safe threshold concentration in water, and the conclusive evidence for adverse effects from occupational exposure. It is recommended that monitoring programs be carried out at sites where asbestos fill is used; data from such programs can be used to determine whether any mitigative measures should be taken. On the basis of estimates made in this study, monitoring for asbestos in drift from cooling towers does not appear to be warranted

  17. Power Tower Technology Roadmap and cost reduction plan.

    Energy Technology Data Exchange (ETDEWEB)

    Mancini, Thomas R.; Gary, Jesse A. (U.S. Department of Energy); Kolb, Gregory J.; Ho, Clifford Kuofei

    2011-04-01

    Concentrating solar power (CSP) technologies continue to mature and are being deployed worldwide. Power towers will likely play an essential role in the future development of CSP due to their potential to provide dispatchable solar electricity at a low cost. This Power Tower Technology Roadmap has been developed by the U.S. Department of Energy (DOE) to describe the current technology, the improvement opportunities that exist for the technology, and the specific activities needed to reach the DOE programmatic target of providing competitively-priced electricity in the intermediate and baseload power markets by 2020. As a first step in developing this roadmap, a Power Tower Roadmap Workshop that included the tower industry, national laboratories, and DOE was held in March 2010. A number of technology improvement opportunities (TIOs) were identified at this workshop and separated into four categories associated with power tower subsystems: solar collector field, solar receiver, thermal energy storage, and power block/balance of plant. In this roadmap, the TIOs associated with power tower technologies are identified along with their respective impacts on the cost of delivered electricity. In addition, development timelines and estimated budgets to achieve cost reduction goals are presented. The roadmap does not present a single path for achieving these goals, but rather provides a process for evaluating a set of options from which DOE and industry can select to accelerate power tower R&D, cost reductions, and commercial deployment.

  18. Virtual and remote control tower research, design, development and validation

    CERN Document Server

    2016-01-01

    The interdisciplinary research and development work carried out in the last ten years which is presented in this book aimed at replacing the conventional airport control tower by a new “remote tower operation” work environment (RTO) which should enhance work efficiency and safety and reduce costs. This revolutionary human–system interface allows for remote aerodrome traffic control without a physical tower building and enables the establishment of remote airport traffic control centers (RTC) of which each may serve several airports from a central location.

  19. Kaiseraugst nuclear power station: meteorological effects of the cooling towers

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Considerations of water conservation persuaded the German Government in 1971 not to allow the use of the Aar and Rhine for direct cooling of nuclear power stations. The criticism is often made that the Kaiseraugst cooling towers were built without full consideration of the resulting meteorological effects. The criticism is considered unjustified because the Federal Cooling Tower Commission considered all the relevant aspects before making its recommendations in 1972. Test results and other considerations show that the effect of the kaiseraugst cooling towers on meteorological and climatic conditions is indeed minimal and details are given. (P.G.R.)

  20. A method for treating bottom ash

    NARCIS (Netherlands)

    Rem, P.C.; Van Craaikamp, H.; Berkhout, S.P.M.; Sierhuis, W.; Van Kooy, L.A.

    2007-01-01

    A method for treating bottom ash from a waste incineration plant. The invention relates in particular to a method for treating bottom ash from a domestic waste incineration plant. In accordance with the invention bottom ash having a size ranging up to 2 mm is treated by removing a previously

  1. The Tower Shielding Facility: Its glorious past

    Energy Technology Data Exchange (ETDEWEB)

    Muckenthaler, F.J.

    1997-05-07

    The Tower Shielding Facility (TSF) is the only reactor facility in the US that was designed and built for radiation-shielding studies in which both the reactor source and shield samples could be raised into the air to allow measurements to be made without interference from ground scattering or other spurious effects. The TSF proved its usefulness as many different programs were successfully completed. It became active in work for the Defense Atomic Support Agency (DASA) Space Nuclear Auxiliary Power, Defense Nuclear Agency, Liquid Metal Fast Breeder Reactor Program, the Gas-Cooled and High-Temperature Gas-Cooled Reactor programs, and the Japanese-American Shielding Program of Experimental Research, just to mention a few of the more extensive ones. The history of the TSF as presented in this report describes the various experiments that were performed using the different reactors. The experiments are categorized as to the programs which they supported and placed in corresponding chapters. The experiments are described in modest detail, along with their purpose when appropriate. Discussion of the results is minimal, but references are given to more extensive topical reports.

  2. Assessment of requirements for dry towers

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, D E; Sonnichsen, J C

    1976-09-01

    The regional limitations of surface water supplies in the U.S. were assessed with respect to the consumptive use requirements of wet cooling towers. The study simulated unit consumptive use factors by region, assessed regional water supplies, and examined electric load projections through 2000 A.D. to ascertain where and when water limitations may occur and, therefore, where dry cooling may be required. It was concluded that the cooling water supply situation in the United States through the year 2000 is adequate in most areas, but is uncertain over much of the Southwest. The uncertainty is related to increasing competition for the available supplies and to potential Federal and/or State policy decisions that may have a significant effect on power plant cooling. Limitations on coastal siting, seismic zone constraints, and state constraints on the purchase and transfer of water rights from other uses to cooling supply have the potential of bringing wet/dry or dry cooling into relatively common use in the 1990's. (LCL)

  3. The Tower Shielding Facility: Its glorious past

    International Nuclear Information System (INIS)

    Muckenthaler, F.J.

    1997-01-01

    The Tower Shielding Facility (TSF) is the only reactor facility in the US that was designed and built for radiation-shielding studies in which both the reactor source and shield samples could be raised into the air to allow measurements to be made without interference from ground scattering or other spurious effects. The TSF proved its usefulness as many different programs were successfully completed. It became active in work for the Defense Atomic Support Agency (DASA) Space Nuclear Auxiliary Power, Defense Nuclear Agency, Liquid Metal Fast Breeder Reactor Program, the Gas-Cooled and High-Temperature Gas-Cooled Reactor programs, and the Japanese-American Shielding Program of Experimental Research, just to mention a few of the more extensive ones. The history of the TSF as presented in this report describes the various experiments that were performed using the different reactors. The experiments are categorized as to the programs which they supported and placed in corresponding chapters. The experiments are described in modest detail, along with their purpose when appropriate. Discussion of the results is minimal, but references are given to more extensive topical reports

  4. Hadron calorimeter towers with a high space resolution

    International Nuclear Information System (INIS)

    Bellettini, G.; Bertani, R.; Bradaschia, C.; Del Fabbro, R.; Scribano, A.; Terreni, G.

    1982-01-01

    The performances of a set of hadron calorimeter towers for measuring the hadron impact point are described. It is shown that an accuracy of 1-2 cm can be achieved with a proper treatment of the data. (orig.)

  5. NAMMA SENEGAL RADIOSONDE AND TOWER FLUX DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The NAMMA Senegal Radiosonde and Tower Flux data includes measurements of humidity, wind speed/direction and velocity. Additionally, the flux data includes...

  6. Final Rule for Industrial Process Cooling Towers: Fact Sheet

    Science.gov (United States)

    Fact sheet concerning a final rule to reduce air toxics emissions from industrial process cooling towers. Air toxics are those pollutants known or suspected of causing cancer or other serious health effects.

  7. Transient Simulation of Wind Turbine Towers under Lightning Stroke

    Directory of Open Access Journals (Sweden)

    Xiaoqing Zhang

    2013-01-01

    Full Text Available A simulation algorithm is proposed in this paper for lightning transient analysis of the wind turbine (WT towers. In the proposed algorithm, the tower body is first subdivided into a discrete multiconductor system. A set of formulas are given to calculate the electrical parameters of the branches in the multiconductor system. By means of the electrical parameters, each branch unit in the multiconductor system is replaced as a coupled π-type circuit and the multiconductor system is converted into a circuit model. Then, the lightning transient responses can be obtained in different parts on the tower body by solving the circuit equations of the equivalent discretization network. The laboratory measurement is also made by a reduced-scale tower for checking the validity of the proposed algorithm.

  8. Natural-draught cooling tower of the Philippsburg-1 reactor

    International Nuclear Information System (INIS)

    Ernst, G.; Wurz, D.

    1983-01-01

    In spring 1980 a comprehensive research programm was carried out on the natural-draught cooling tower of the Philippsburg-1 reactor. The study was meant to synchronously acquire all parameters necessary for the evaluation of plant operation and cooling tower emissions. The study is subdivided into 8 sub-projects. Parts 1 to 7 that are included in this progress-of-work report describe experimental work and discuss the results. A critical analysis of measuring results proves that the values for operational behaviour and cooling tower emissions were duly anticipated. Even a very critical judgment of the results can exclude direct or indirect hazards for humans, animals and plants owing to cooling tower emissions. Sub-project 8 compares results from diffusion calculations (24 models) to results gained from experiments. The results of sub-project 8 will be published in a progress report to come. (orig.) [de

  9. NAMMA SENEGAL RADIOSONDE AND TOWER FLUX DATA V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The NAMMA Senegal Radiosonde and Tower Flux data includes measurements of humidity, wind speed/direction and velocity. Additionally the Flux data includes...

  10. Evaluation of Tower Shadowing on Anemometer Measurements at Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, David Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-14

    The objective of this study is to evaluate the effect of tower shadowing from the meteorology towers at LANL during 2014. This study is in response to the Department of Energy Meteorological Coordinating Council visit in 2015 that recommended an evaluation of any biases in the wind data introduced by the tower and boom alignment at all meteorology towers.

  11. Performance evaluations of steam power plants with dry cooling towers

    International Nuclear Information System (INIS)

    Fortunato, B.; Magi, V.

    1984-01-01

    A theoretical model is presented to design dry cooling tower systems and to evaluate their off-design performances. The influence of the more important design parameters on the tower dimensions is shown. A preliminary ''optimum'' size is predicted by means of a computer code using a simplified cost model. Moreover the influence of the designed cooling system on the performance of thermoelectric and/or nuclear power plants is analysed

  12. Fatigue Analysis of a Mono-Tower Platform

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Sørensen, John Dalsgaard; Brincker, Rune

    In this paper, a fatigue reliability analysis of a Mono-tower platform is presented. The failure mode, fatigue failure in the butt welds, is investigated with two different models. The one with the fatigue strength expressed through SN relations, the other with the fatigue strength expressed...... of the natural period, damping ratio, current, stress Spectrum and parameters describing the fatigue strength. Further, soil damping is shown to be significant for the Mono-tower....

  13. Evaluation of dynamic response for monopole and hybrid wind mill tower

    Science.gov (United States)

    Shah, Hemal J.; Desai, Atul K.

    2017-07-01

    The wind mill towers are constructed using monopoles or lattice type tower. As the height of tower increases it gives more power but it becomes uneconomical, so in the present research work innovative wind mill tower such as combination of monopole and lattice tower is analyzed using FEM software. When the tall structures are constructed on soft soil it becomes dynamically sensitive so 3 types of soil such as hard, medium and soft soil is also modeled and the innovative tower is studied for different operating frequencies of wind turbine. From study it is concluded that the innovative tower will reduce resonance condition considering soil structure interaction.

  14. Exergy analysis of a distillation tower for crude oil fractionation

    International Nuclear Information System (INIS)

    Rivero, R.

    1990-01-01

    In this paper the application of the exergy method to a crude oil atmospheric distillation tower is presented. The fundamentals and procedures are presented as well as the main parameters used to describe the thermodynamic performance of the system, such as Exergy Losses, Effectiveness and Improvement Potential. A parametric analysis of the influence on the effectiveness of the tower is then performed as a function of the number of trays, the amount of stripping steam, the use of reboilers and the operation pressure. The results obtained are discussed. As expected, the effectiveness of the tower increases with the overall number of trays in the tower and in the stripping columns for a constant operation pressure and a constant amount of stripping steam but there is a limit at which the pressure drop across the trays and the stripping steam requirements make the effectiveness decrease. The use of reboilers in the stripping columns adjacent to the main tower allows an increase in the effectiveness basically due to a greater heat integration. Finally, the increase in the operation pressure of the tower produces an increase of the effectiveness but also an increase in the stripping steam requirements

  15. Short Duration Reduced Gravity Drop Tower Design and Development

    Science.gov (United States)

    Osborne, B.; Welch, C.

    The industrial and commercial development of space-related activities is intimately linked to the ability to conduct reduced gravity research. Reduced gravity experimentation is important to many diverse fields of research in the understanding of fundamental and applied aspects of physical phenomena. Both terrestrial and extra-terrestrial experimental facilities are currently available to allow researchers access to reduced gravity environments. This paper discusses two drop tower designs, a 2.0 second facility built in Australia and a proposed 2.2 second facility in the United Kingdom. Both drop towers utilise a drag shield for isolating the falling experiment from the drag forces of the air during the test. The design and development of The University of Queensland's (Australia) 2.0 second drop tower, including its specifications and operational procedures is discussed first. Sensitive aspects of the design process are examined. Future plans are then presented for a new short duration (2.2 sec) ground-based reduced gravity drop tower. The new drop tower has been designed for Kingston University (United Kingdom) to support teaching and research in the field of reduced gravity physics. The design has been informed by the previous UQ drop tower design process and utilises a catapult mechanism to increase test time and also incorporates features to allow participants for a variety of backgrounds (from high school students through to university researchers) to learn and experiment in reduced gravity. Operational performance expectations for this new facility are also discussed.

  16. Feasibility of Batch Reactive Distillation with Equilibrium-Limited Consecutive Reactions in Rectifier, Stripper, or Middle-Vessel Column

    Directory of Open Access Journals (Sweden)

    T. Lukács

    2011-01-01

    Full Text Available A general overall feasibility methodology of batch reactive distillation of multireaction systems is developed to study all the possible configurations of batch reactive distillation. The general model equations are derived for multireaction system with any number of chemical equilibrium-limited reactions and for any number of components. The present methodology is demonstrated with the detailed study of the transesterification of dimethyl carbonate in two reversible cascade reactions in batch reactive distillation process. Pure methanol is produced as distillate, and pure diethyl carbonate is produced at the bottom simultaneously in middle-vessel column; in each section, continuous feeding of ethanol is necessary. The results of feasibility study are successfully validated by rigorous simulations.

  17. Probabilistic Capacity Assessment of Lattice Transmission Towers under Strong Wind

    Directory of Open Access Journals (Sweden)

    Wei eZhang

    2015-10-01

    Full Text Available Serving as one key component of the most important lifeline infrastructure system, transmission towers are vulnerable to multiple nature hazards including strong wind and could pose severe threats to the power system security with possible blackouts under extreme weather conditions, such as hurricanes, derechoes, or winter storms. For the security and resiliency of the power system, it is important to ensure the structural safety with enough capacity for all possible failure modes, such as structural stability. The study is to develop a probabilistic capacity assessment approach for transmission towers under strong wind loads. Due to the complicated structural details of lattice transmission towers, wind tunnel experiments are carried out to understand the complex interactions of wind and the lattice sections of transmission tower and drag coefficients and the dynamic amplification factor for different panels of the transmission tower are obtained. The wind profile is generated and the wind time histories are simulated as a summation of time-varying mean and fluctuating components. The capacity curve for the transmission towers is obtained from the incremental dynamic analysis (IDA method. To consider the stochastic nature of wind field, probabilistic capacity curves are generated by implementing IDA analysis for different wind yaw angles and different randomly generated wind speed time histories. After building the limit state functions based on the maximum allowable drift to height ratio, the probabilities of failure are obtained based on the meteorological data at a given site. As the transmission tower serves as the key nodes for the power network, the probabilistic capacity curves can be incorporated into the performance based design of the power transmission network.

  18. EDF's ageing management program for cooling towers

    International Nuclear Information System (INIS)

    Roure, T.; Crolet, Y.

    2015-01-01

    EDF operates a large fleet of cooling towers for its thermal and nuclear plants. Proactive maintenance strategies require ranking the towers according to the risk of failure and the observed damage. The ranking includes monitoring data such as: foundation settlements, material properties, quantified crack patterns, shell deformation, meteorological data, and corrosion. The numerical tool suite includes a finite element analysis of each tower under thermal and mechanical loadings and a corrosion predicting tool, based on carbonation. The first module computes the behavior of cooling towers under five types of loading: soil differential settlement, self-weight, moisture transport, temperature and wind. By comparison with the ultimate resisting capacity of the reinforced concrete cross section, a risk index map is produced for each tower. This risk index is used to rank the cooling towers and then to identify which structures should be monitored more closely or reinforced - if needed - first in the case of an extended operating life. The second module aims to anticipate the corrosion depth of reinforcement steel of the towers in the future. Examination of the existing carbonation is currently done for each structure and evolution of the carbonation depth is computed so as to predict with reasonable assurance when carbonation reaches the rebars. A prediction of the eventual cross-section loss of rebars is then made for long term analysis (i.e. up to 60 years of operating life). When corrosion is predicted the first module takes into account this loss and computes the behavior of the predicted corrosion damaged structure under the same loadings. (authors)

  19. Advanced wet--dry cooling tower concept performance prediction

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, T.; Bentley, J.; Giebler, M.; Glicksman, L.R.; Rohsenow, W.M.

    1977-01-01

    The purpose of this year's work has been to test and analyze the new dry cooling tower surface previously developed. The model heat transfer test apparatus built last year has been instrumented for temperature, humidity and flow measurement and performance has been measured under a variety of operating conditions. Tower Tests showed approximately 40 to 50% of the total energy transfer as taking place due to evaporation. This can be compared to approximately 80 to 85% for a conventional wet cooling tower. Comparison of the model tower test results with those of a computer simulation has demonstrated the validity of that simulation and its use as a design tool. Computer predictions have been made for a full-size tower system operating at several locations. Experience with this counterflow model tower has suggested that several design problems may be avoided by blowing the cooling air horizontally through the packing section. This crossflow concept was built from the previous counterflow apparatus and included the design and fabrication of new packing plates. Instrumentation and testing of the counterflow model produced data with an average experimental error of 10%. These results were compared to the predictions of a computer model written for the crossflow configuration. In 14 test runs the predicted total heat transfer differed from the measured total heat transfer by no more than 8% with most runs coming well within 5%. With the computer analogy's validity established, it may now be used to help predict the performance of fullscale wet-dry towers.

  20. Thermal design guidelines of solar power towers

    International Nuclear Information System (INIS)

    Rodríguez-Sánchez, M.R.; Soria-Verdugo, Antonio; Almendros-Ibáñez, José Antonio; Acosta-Iborra, Antonio; Santana, Domingo

    2014-01-01

    One of the main problems of solar power tower plants with molten salt as heat transfer fluid is the reliability of central receivers. The receiver must withstand high working temperatures, molten salt corrosion and important solar flux transients that lead to thermal stresses and fatigue. Despite these difficulties, it is necessary an estimation of the receiver thermal efficiency in order to have an accurate estimation of the investment cost of the solar plant and to assure the lifetime estimation of the receiver. A thermal, mechanical and hydrodynamic analysis of these receivers has been developing in this work, assuming constant heat flux in each axial discretized section of the tube wall but considering circumferential temperature variations in the perimeter of the tubes caused by the difference between the heat flux received by the front part of the tubes and by the rear part. The thermal analysis shows that the radiation losses are higher than in literature, and consequently the thermal efficiency is lower too. This is due to the fact that the effective tube wall temperature for radiation is higher than the mean tube wall temperature, especially if the rear temperature of the tubes is considered. Besides, it has been found that the highest temperatures and thermal stresses are sited on the eastern and western panels of the receivers. Film temperature is the most limiting parameter for the receiver design due to it is responsible for salt decomposition and tube corrosion. Therefore, once the tube material is chosen, the film temperature cannot exceed a critical value over which the corrosion ratio raises rapidly. Small tube diameters and low number of panels results in low film temperatures, although this kind of design increases the pressure drop. Therefore, a compromise between film temperature and pressure drop can lead to a receiver design that ensures its lifetime, and at the same time, optimizes the investment and operational cost of the receiver

  1. Improvement of coal focus and cooling towers of COFRENTES NPP

    International Nuclear Information System (INIS)

    Martinez, I.; Bogh, P.

    1998-01-01

    Cofrentes Nuclear Power Plant is performing a improving program of its cooling towers based on the filling revamping and cooling water circuit improvement. Furthermore, and as consequence of the acquired experience on cooling towers due to the mentioned program, Cofrentes NPP has decided to follow up with this project from a different point of view based on the thermal-hydraulic optimization of the cooling process inside the towers. This program, which is going to be carried out by Cofrentes NPP, Iberinco and Energy Planning and Power Generation (EPPG) provides an improvement on the thermal profile and of the draught inside the cooling towers by improving the water distribution in the towers active area. In order to perform such a program is needed to fulfill a test program to assure a guaranteed performance gain. In this way, Iberinco is developing a test procedure which improves the results which are obtained with the present standards used commonly by the industry. As a consequence of this program, Cofrentes is expecting to obtain a gain of 5 to 8 MWe with a revenue period of 4 to 5 months, results validated in another foreigner Plant which have developed a similar program. (Author)

  2. Legionella safety in cooling towers; Legionellaveiligheid in koeltorens

    Energy Technology Data Exchange (ETDEWEB)

    Kordes, B. [Kordes Advies, (Netherlands); De Bok, F. [KBBL Wijhe, (Netherlands); De Zeeuw, L. [Holland Environment Group, (Netherlands); Settels, P. [Safety, Health Services and Ergonomics, ING, (Netherlands); Oesterholt, F.; Wullings, B. [KWR Watercycle Research Institute, (Netherlands); Guiot, P. [Tevan, Gorinchem (Netherlands); Brands, R. [Cumulus Nederland, Cuijk (Netherlands); Nuijten, O. [Kennisinstituut ISSO, Rotterdam (Netherlands); Wijne, R. [Beer advocaten, Amsterdam (Netherlands)

    2010-04-15

    In 9 articles attention is paid to several aspects with regard to Legionella in cooling towers: representative sampling, the use of copper and silver ionization or hydrogen peroxide to prevent Legionella growth and biofilms, the use of a zero-tolerance model to control a cooling tower installation, detection of DNA of Legionella Pneumophila, legionella safety in air conditioners, the model Legionella risk analysis and control of cooling tower installations, legislation and regulations for the control of cooling tower installations with regard to the Dutch Occupational Health and Safety Act ('Arbo-wet'), and an article about a lawsuit for victims of a Legionella outbreak, caused by careless owners of a cooling tower in Amsterdam, Netherlands. [Dutch] In 9 artikelen wordt in deze aflevering aandacht besteed aan verschillende aspecten m.b.t. Legionella in koeltorens: representatieve monstername, de toepassing van koper en zilver-ionisatie of waterstofperoxide om de groei van Legionella en biofilms te voorkomen, het gebruik van een zero-tolerance model om een koeltoren installatie te controleren, detectie van DNA van Legionella Pneumophila, Legionella veiligheid in luchtbehandelingsinstallaties, het model Legionella risicoanalyse en beheersplan voor koeltoreninstallaties, de rol van de Arbo-wet, en een artikel over een rechtszaak voor slachtoffers van Legionella door onzorgvuldig beheer van een koeltoren in Amsterdam.

  3. Modification of the colony tower for the Rio Blanco detonation

    International Nuclear Information System (INIS)

    Blume, J.A.; Freeman, S.A.; Honda, K.K.; Lee, L.A.

    1975-01-01

    Supplemental structural bracing was designed and installed for the 180-ft-tall Colony Tower, an experimental oil shale processing retort structure, in anticipation of its lateral response to the Rio Blanco detonation. The tower is a steel structure with both horizontal and vertical diagonal bracing. Data obtained from the earlier Project Rulison detonation indicated that an evaluation study was necessary. Design criteria that would provide an adequate margin of safety were developed based on predicted Rio Blanco ground motion. The evaluation of the unmodified structure showed that several bracing members would be subjected to forces exceeding their yield strength, and some would reach a level at which failure could occur. Further analyses were made with assumed modified bracing members. A final scheme for modified vertical bracing was established and installed. After modification, the response of the tower during the Rio Blanco detonation was measured by instruments on the ground and at various locations on the tower, and no evidence of damage was discovered. The modification of the Colony Tower and the procedures used to determine these modifications show the usefulness of current ground motion and structural response prediction technology for forecasting dynamic behavior of important structures subjected to ground motion from underground nuclear explosions. (auth)

  4. Coal liquefaction with subsequent bottoms pyrolysis

    Science.gov (United States)

    Walchuk, George P.

    1978-01-01

    In a coal liquefaction process wherein heavy bottoms produced in a liquefaction zone are upgraded by coking or a similar pyrolysis step, pyrolysis liquids boiling in excess of about 1000.degree. F. are further reacted with molecular hydrogen in a reaction zone external of the liquefaction zone, the resulting effluent is fractionated to produce one or more distillate fractions and a bottoms fraction, a portion of this bottoms fraction is recycled to the reaction zone, and the remaining portion of the bottoms fraction is recycled to the pyrolysis step.

  5. Charge-state distribution measurements of ^{238}U and ^{136}Xe at 11  MeV/nucleon using gas charge stripper

    Directory of Open Access Journals (Sweden)

    H. Kuboki

    2010-09-01

    Full Text Available The charge-state distributions and equilibrium charge states of uranium (^{238}U and xenon (^{136}Xe ions at 11  MeV/nucleon were determined using a gas charge stripper. A differential pumping system facilitated the increase of the nitrogen gas thickness up to 1.3  mg/cm^{2}, which is sufficient for the most probable charge state to attain equilibrium. The charge states of ^{238}U attain equilibrium at 56.0, 56.6, and 55.7 in N_{2}, Ar, and CO_{2} media with thicknesses of 125, 79, and 126  μg/cm^{2}, respectively, while those of ^{136}Xe attain equilibrium at 40.5, 40.1, and 40.3 in N_{2}, Ar, and CO_{2} media with thicknesses of 163, 95, and 139  μg/cm^{2}, respectively. The equilibrium charge states of ^{136}Xe are acceptable for acceleration by the subsequent cyclotron. The measured data of ^{238}U were used to devise an empirical formula for the prediction of the equilibrium charge state in gaseous media over the energy region of 0.01–60  MeV/nucleon. The equilibrium charge state of ^{136}Xe as predicted by the devised formula is in good agreement with the data.

  6. Induced flocculation of Pachysolen tannophilus using the tower fermentor

    Energy Technology Data Exchange (ETDEWEB)

    Deverell, K.F.; Clark, T.A.

    1985-12-01

    This article reports the induction of flocculation with Pachysolen tannophilus by the use of controlled aeration in a tower fermentor. The observed environmental and physiological conditions for flocculent growth are described. Although most studies with P. tannophilus have used oxylose as substrate, a synthetic glucose medium was chosen for this study as the faster growth rate of the organism on glucose was considered to favor more rapid selection of a flocculent strain. Due to flocculation, the concentration of yeast cells retained in the tower was up to 16 times greater than in the overflow. Ethanol yields approaching theoretical were achieved at low specific oxygen uptake rates, conditions which also favored maximum flocculation. Future work will involve continuous tower fermentation of sugar mixtures representative of the composition of wood hydrolysates.

  7. One-year dynamic monitoring of a masonry tower

    Directory of Open Access Journals (Sweden)

    Guidobaldi Marco

    2015-01-01

    Full Text Available The paper presents some results of the continuous dynamic monitoring program carried out on the tallest historic tower in Mantua, Italy. This project follows an extensive diagnostic investigation aimed at assessing the structural condition of the tower after the Italian earthquakes of May 2012. A simple dynamic monitoring system was permanently installed in the upper part of the building and automatic modal identification was performed. The results allow to evaluate the effects of changing temperature on automatically identified natural frequencies, to verify the practical feasibility of damage detection methods based on natural frequencies shifts and provide clear evidence of the possible key role of continuous dynamic monitoring in the preventive conservation of historic towers.

  8. An integrated reliability-based design optimization of offshore towers

    International Nuclear Information System (INIS)

    Karadeniz, Halil; Togan, Vedat; Vrouwenvelder, Ton

    2009-01-01

    After recognizing the uncertainty in the parameters such as material, loading, geometry and so on in contrast with the conventional optimization, the reliability-based design optimization (RBDO) concept has become more meaningful to perform an economical design implementation, which includes a reliability analysis and an optimization algorithm. RBDO procedures include structural analysis, reliability analysis and sensitivity analysis both for optimization and for reliability. The efficiency of the RBDO system depends on the mentioned numerical algorithms. In this work, an integrated algorithms system is proposed to implement the RBDO of the offshore towers, which are subjected to the extreme wave loading. The numerical strategies interacting with each other to fulfill the RBDO of towers are as follows: (a) a structural analysis program, SAPOS, (b) an optimization program, SQP and (c) a reliability analysis program based on FORM. A demonstration of an example tripod tower under the reliability constraints based on limit states of the critical stress, buckling and the natural frequency is presented.

  9. Membrane distillation of industrial cooling tower blowdown water

    Directory of Open Access Journals (Sweden)

    N.E. Koeman-Stein

    2016-06-01

    Full Text Available The potential of membrane distillation for desalination of cooling tower blowdown water (CTBD is investigated. Technical feasibility is tested on laboratory and pilot scale using real cooling tower blowdown water from Dow Benelux in Terneuzen (Netherlands. Two types of membranes, polytetrafluorethylene and polyethylene showed good performance regarding distillate quality and fouling behavior. Concentrating CTBD by a factor 4.5 while maintaining a flux of around 2 l/m2*h was possible with a water recovery of 78% available for reuse. Higher concentration factors lead to severe decrease in flux which was caused by scaling. Membrane distillation could use the thermal energy that would otherwise be discharged of in a cooling tower and function as a heat exchanger. This reduces the need for cooling capacity and could lead to a total reduction of 37% water intake for make-up water, as well as reduced energy and chemicals demands and greenhouse gas emissions.

  10. A modular restoration tower for electric power line transmission

    Energy Technology Data Exchange (ETDEWEB)

    Nicolazzi, L.C.; Pereira, J.C.; Leonel, C.E.L.; Rocha, G.B.; Bianchezzi, V.; Mendes, F. [Universidade Federal Santa Catarina (UFSC), Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica], Emails: lauro@grante.ufsc.br, jcarlos@grante.ufsc.br; Luz, R.L. [ELETROSUL Centrais Eletricas S.A., Florianopolis, SC (Brazil)], Email: rluz@eletrosul.gov.br

    2009-07-01

    The main target of this R and D project is to develop an restoration tower for electric energy lines transmission. Whereas these towers should present the main features like transport facility, easiest assembling associated with a low cost of manufacture, it was applied the single-column tower concepts supported by stays, modularized, framed and articulated at the base. The concepts used for this development was a design methodology. From the different definition situations of load, numerical models have been developed focusing the design to the best of structural element arrangements of its modules. Then, tests were performed in laboratory to determine the module structural performance for different work load situations. These tests served to identify inconsistencies in the numerical models and proposed adjustments in its design to improve its performance on the strength and stability. (author)

  11. Anchoring wind turbine towers in steel using construction elements of concrete and CRC; Compact reinforced composite; Forankring af vindmoelletaarne i staal ved anvendelse af konstruktionselementer i beton og CRC

    Energy Technology Data Exchange (ETDEWEB)

    2005-07-15

    During the past 25 to 30 years extensive R and D projects within concrete technology have been carried out. The result of this work is high-strength concrete that consists of fibres and reinforced materials. Traditionally wind turbine towers are fastened to the foundation using an embedded steel ring with a flange ring in the top surface. The maximum tower diameter of 4.5 m, set on the grounds of road transport, is now playing a significant role in this connection. This report presents results from a study of the possibilities for using a connecting piece made from concrete anchored directly in the turbine foundations' base and placed on top of the foundation bolted to the towers' bottom flange. High-strength concrete has been studied as an alternative to ordinary concrete. the results show that anchoring the tower in the foundation using reinforcement passively anchored in the bottom of the foundation and supported by a concrete/CRC connecting piece has a number of advantages compared to traditional solutions. (BA)

  12. Integration of Small Solar Tower Systems Into Distributed Power Islands

    International Nuclear Information System (INIS)

    Romero, M.; Marcos, M. J.; Tellez, F. M.; Blanco, M.; Fernandez, V.; Baonza, F.; Berger, S.

    1999-01-01

    One of the short-term priorities for renewable energies in Europe is their integration for local power supply into communities and energy islands (blocks of buildings, new neighborhoods in residential areas, shopping centers, hospitals, recreational areas, eco-parks, small rural areas or isolated ones such as islands or mountain communities). Following this strategy, the integration of small tower fields into so-called MIUS (Modular Integrated Utility Systems) is proposed. This application strongly influences field concepts leading to modular multi-tower systems able to more closely track demand, meet reliability requirements with fewer megawatts of installed power and spread construction costs over time after output has begun. In addition, integration into single-cycle high-efficiency gas turbines plus waste-heat applications clearly increments the solar share. The chief questions are whether solar towers can be redesigned for such distributed markets and the keys to their feasibility. This paper includes the design and performance analysis of a 1.36-MW plant and integration in the MIUS system, as well as the expected cost of electricity and a sensitivity analysis of the small tower plant's performance with design parameters like heliostats configuration and tower height. A practical application is analyzed for a shopping center with 85% power demand during day-time by using a hybrid solar tower and a gas turbine producing electricity and waste heat for hot water and heating and cooling of spaces. The operation mode proposed is covering night demand with power from the grid and solar-gas power island mode during 14 hours daytime with a maximum power production of 1.36 MW. (Author) 26 refs

  13. Integration of Small Solar tower Systems into Distributed Power Islands

    Energy Technology Data Exchange (ETDEWEB)

    Romero, M.; Marcos, M. J.; Tellez, F. M.; Blanco, M.; Fernandez, V.; Baonza, F.; Berger, S. [Ciemat, Madrid (Spain)

    2000-07-01

    One of the short-term priorities for renewable energies in Europe is their integration for local power supply into communities and energy islands (blocks of buildings, new neighborhoods in residential areas, shopping centers, hospitals, recreational areas, eco-paks, small rural areas or isolated ones such as islands or mountain communities). Following this strategy, the integration of small tower fields into so-called MIUS (Modular Integrated Utility Systems) is proposed. This application strongly influences field concepts leadings to modular multi-tower systems able to more closely track demand, meet reliability requirements with fewer megawatts of installed power and spread construction costs over time after output has begum. In addition, integration into single-cycle high-efficiency gas turbines plus waste-heat applications clearly increments the solar share. The chief questions are whether solar towers can be redesigned for such distributed markets and the keys to their feasibility. This paper includes the design and performance analysis of a 1.36-MW plant and integration in the MIUS system, as well as the expected cost of electricity and a sensitivity analysis of the small tower plant's performance with design parameters like heliostat configuration and tower height. A practical application is analyzed for a shopping center with 85% power demand during day-time by using a hybrid solar tower and a gas turbine producing electricity and waste heat for hot water and heating and cooling of spaces. The operation mode proposed is covering night demand with power from the grid and solar-gas power island mode during 14 hours daytime with a maximum power production of 1.36 MW. (Author) 26 refs.

  14. Desalination using spray tower and vapour compression refrigeration system

    International Nuclear Information System (INIS)

    Sathish Kumar, S.; Mani, A.

    2006-01-01

    A desalination system using a spray tower and Vapour Compression Refrigeration (VCR) system is proposed for obtaining fresh water from brackish water. In the spray tower, simultaneous heat and mass transfer take place between the brackish water and air, which results in the evaporation of the brackish water and humidification of the air. Fresh water is obtained from the humidified air by condensing the water vapour using a VCR system. Parametric studies were carried out to study the effect of various operational parameters on the fresh water production rate. (author)

  15. Energy and exergy analysis of counter flow wet cooling towers

    Directory of Open Access Journals (Sweden)

    Saravanan Mani

    2008-01-01

    Full Text Available Cooling tower is an open system direct contact heat exchanger, where it cools water by both convection and evaporation. In this paper, a mathematical model based on heat and mass transfer principle is developed to find the outlet condition of water and air. The model is solved using iterative method. Energy and exergy analysis infers that inlet air wet bulb temperature is found to be the most important parameter than inlet water temperature and also variation in dead state properties does not affect the performance of wet cooling tower. .

  16. Towards Cooling Tower Efficiency-An Energy Audit Approach

    Directory of Open Access Journals (Sweden)

    Long Su Weng Alwin

    2017-01-01

    Full Text Available This research studied the power generation trends from national grid and gas for a period of 4 years. Energy audit of critical systems like this is needful for optimal energy utilization. An energy audit was carried outon 6 industrial cooloing towers and their annual operating cost calculated. Variable speed drive suggested was installed and corresponding annual energy savings of 114,900 kWh/year cost saving of RM30,000 was achieved at a case study plant located in Malaysia. Cooling towers with smart systems was recommended for higher energy savings.

  17. Dry cooling tower operating experience in the LOFT reactor

    International Nuclear Information System (INIS)

    Hunter, J.A.

    1980-01-01

    A dry cooling tower has been uniquely utilized to dissipate heat generated in a small experimental pressurized water nuclear reactor. Operational experience revealed that dry cooling towers can be intermittently operated with minimal wind susceptibility and water hammer occurrences by cooling potential steam sources after a reactor scram, by isolating idle tubes from the external atmosphere, and by operating at relatively high pressures. Operating experience has also revealed that tube freezing can be minimized by incorporating the proper heating and heat loss prevention features

  18. Calculation of cooling tower plumes for high pressure wintry situations

    International Nuclear Information System (INIS)

    Gassmann, F.; Tinguely, M.; Haschke, D.

    1982-12-01

    The diffusion of the plumes of the projected nuclear power plants at Kaiseraugst and Schwoerstadt, during high pressure wintry conditions, has been examined using a mathematical model to simulate the plumes. For these calculations, microaerological measurements were made in the proximity of Kaiseraugst and Schwoerstadt. These give a typical image of the weather during high pressure wintry conditions, which is normally associated with an inversion, sometimes strong, at a low height. Dry cooling towers with natural draught, which offer an alternative solution to the wet cooling towers proposed for Kasieraugst, are examined equally. (Auth./G.T.H.)

  19. Environmental Tests of the Flight GLAST LAT Tracker Towers

    Energy Technology Data Exchange (ETDEWEB)

    Bagagli, R.; Baldini, L.; Bellazzini, R.; Barbiellini, G.; Belli, F.; Borden, T.; Brez, A.; Brigida, M.; Caliandro, G.A.; Cecchi, C.; Cohen-Tanugi, J.; Angelis, A.De; Drell, P.; Favuzzi, C.; Fusco, P.; Gargano, F.; Germani, S.; Giglietto, N.; Giordano, F.; Goodman, J.; Himel, T.

    2008-03-12

    The Gamma-ray Large Area Space telescope (GLAST) is a gamma-ray satellite scheduled for launch in 2008. Before the assembly of the Tracker subsystem of the Large Area Telescope (LAT) science instrument of GLAST, every component (tray) and module (tower) has been subjected to extensive ground testing required to ensure successful launch and on-orbit operation. This paper describes the sequence and results of the environmental tests performed on an engineering model and all the flight hardware of the GLAST LAT Tracker. Environmental tests include vibration testing, thermal cycles and thermal-vacuum cycles of every tray and tower as well as the verification of their electrical performance.

  20. Two upward lightning at the Eagle Nest tower

    OpenAIRE

    Montañá Puig, Juan; Van der Velde, Oscar Arnoud; Romero Durán, David; March Nomen, Víctor; Solà de Las Fuentes, Gloria; Pineda Ruegg, Nicolau; Soula, Serge; Hermoso Alameda, Blas

    2012-01-01

    A new instrument composed by a high speed camera, two high energy detectors, a E-field antenna and a VHF antenna were installed at the Eagle Nest tower (northeast of Spain) during summer 2011. With this equipment several lightning flashes to the tower and its vicinity have been observed. This paper presents two examples: the first was an upward negative leader triggered by a close c1oud-to-ground flash and the second was an upward negative flash not associated with previous lightning activity...

  1. Reliability Analysis of a Mono-Tower Platform

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Enevoldsen, I.; Sørensen, John Dalsgaard

    In this paper a reliability analysis of a Mono-tower platform is presented. The failure modes, considered, are yelding in the tube cross-sections, and fatigue failure in the butt welds. The fatigue failure mode is investigated with a fatigue model, where the fatigue strength is expressed through SN...... for the fatigue limit state is a significant failure mode for the Mono.tower platform. Further, it is shown for the fatigue failure mode the the largest contributions to the overall uncertainty are due to the damping ratio, the inertia coefficient, the stress concentration factor, the model uncertainties...

  2. Wet physical separation of MSWI bottom ash

    NARCIS (Netherlands)

    Muchova, L.

    2010-01-01

    Bottom ash (BA) from municipal solid waste incineration (MSWI) has high potential for the recovery of valuable secondary materials. For example, the MSWI bottom ash produced by the incinerator at Amsterdam contains materials such as non-ferrous metals (2.3%), ferrous metals (8-13%), gold (0.4 ppm),

  3. Bottom ash test section evaluation Erwinville, LA.

    Science.gov (United States)

    2009-02-01

    Bottom ash is a by-product of the energy industry and the residual of burning coal in a kiln : firing process. Bottom ash is black and the consistency of coarse sand with gravel clinker : traces. The product is used in other states as embankment mate...

  4. Development of Crashworthy Bottom and Side Structures

    DEFF Research Database (Denmark)

    Naar, H.; Kujala, P.; Simonsen, Bo Cerup

    2002-01-01

    structures. The first structure is a conventional double bottom. In the second structure (presently protected through a patent) the bottom plating is stiffened with hat-profiles instead of bulb profiles. In the third structure the outer shell is an all-steel sandwich panel. In the fourth structure the bottom......The purpose of this work is to compare the resistance to damage of various types of double bottom structures in a stranding event. The results can also be interpreted as the crashworthiness of side structures penetrated by a striking vessel in a collision event. The comparative analyses are made...... by use of a commercial, explicit finite element program. The ship bottom is loaded with a conical indenter with a rounded tip, which is forced laterally into the structures in different positions. The aim is to compare resistance forces, energy absorption and penetration to fracture for four different...

  5. Short-term fatigue analysis for tower base of a spar-type wind turbine under stochastic wind-wave loads

    Directory of Open Access Journals (Sweden)

    Haoran Li

    2018-01-01

    Full Text Available Due to integrated stochastic wind and wave loads, the supporting platform of a Floating Offshore Wind Turbine (FOWT has to bear six Degrees of Freedom (DOF motion, which makes the random cyclic loads acting on the structural components, for instance the tower base, more complicated than those on bottom-fixed or land-based wind turbines. These cyclic loads may cause unexpected fatigue damages on a FOWT. This paper presents a study on short-term fatigue damage at the tower base of a 5 MW FOWT with a spar-type platform. Fully coupled time-domain simulations code FAST is used and realistic environment conditions are considered to obtain the loads and structural stresses at the tower base. Then the cumulative fatigue damage is calculated based on rainflow counting method and Miner's rule. Moreover, the effects of the simulation length, the wind-wave misalignment, the wind-only condition and the wave-only condition on the fatigue damage are investigated. It is found that the wind and wave induced loads affect the tower base's axial stress separately and in a decoupled way, and the wave-induced fatigue damage is greater than that induced by the wind loads. Under the environment conditions with rated wind speed, the tower base experiences the highest fatigue damage when the joint probability of the wind and wave is included in the calculation. Moreover, it is also found that 1 h simulation length is sufficient to give an appropriate fatigue damage estimated life for FOWT.

  6. A ocean bottom vector magnetometer

    Science.gov (United States)

    Wang, Xiaomei; Teng, Yuntian; Wang, Chen; Ma, Jiemei

    2017-04-01

    The new development instrument with a compact spherical coil system and Overhauser magnetometer for measuring the total strength of the magnetic field and the vectors of strength, Delta inclination - Delta declination, meanwhile we also use a triaxial fluxgate instrument of the traditional instrument for geomagnetic vector filed measurement. The advantages of this method are be calibrated by each other and get good performances with automatic operation, good stability and high resolution. Firstly, a brief description of the instrument measurement principles and the key technologies are given. The instrument used a spherical coil system with 34 coils to product the homogeneous volume inside the coils which is large enough to accommodate the sensor of Overhauser total field sensor; the rest of the footlocker-sized ocean-bottom vector magnetometer consists of equipment to run the sensors and records its data (batteries and a data logger), weight to sink it to the sea floor, a remote-controlled acoustic release and flotation to bring the instrument back to the surface. Finally, the accuracy of the instrument was tested in the Geomagnetic station, and the measurement accuracies of total strength and components were better than 0.2nT and 1nT respectively. The figure 1 shows the development instrument structure. it includes six thick glass spheres which protect the sensor, data logger and batteries from the pressures of the deep sea, meanwhile they also provide recycling positive buoyancy; To cushion the glass, the spheres then go inside yellow plastic "hardhats". The triaxial fluxgate is inside No.1 glass spheres, data logger and batteries are inside No.2 glass spheres, the new vector sensor is inside No.3 glass spheres, acoustic communication unit is inside No.4 glass spheres, No.5 and No.6 glass spheres are empty which only provide recycling positive buoyancy. The figure 2 shows the development instrument Physical photo.

  7. Measurement of NOx and CO Fluxes from a Tall Tower in Beijing.

    Science.gov (United States)

    Squires, F. A.; Drysdale, W. S.; Hamilton, J.; Lee, J. D.; Vaughan, A. R.; Wild, O.; Mullinger, N.; Nemitz, E.; Metzger, S.; Zhang, Q.

    2017-12-01

    China's air quality problems are well publicised; in 2010, 1.2 million premature deaths were attributed to outdoor air pollution in China. One of the major air quality issues is high concentrations of nitrogen oxides (NOx). China is the largest NOx emitter, contributing an estimated 18 % to global NOx emissions. Beijing itself is reported to have NO2 concentrations 42 % higher than the annual national standard. Given the high levels of pollution, increased focus has been placed on improving emissions estimates which are typically developed using a `bottom-up' approach where emissions are predicted from their sources. Emission inventories in China have large uncertainties and are rapidly changing with time in response to economic development, environmental regulation and new technologies. In fact, China is the largest contributor to the uncertainty in the source and the magnitude of air pollutants in air quality models. Recent studies have shown a discrepancy between NOx inventories and measured NOx emissions for UK cities, highlighting the limitations of bottom-up emissions inventories and the importance of accurate measurement data to improve the estimates. 5 Hz measurements of NOx and CO concentration were made as part of the Air Pollutants in Beijing (AIRPOLL-Beijing) project during two field campaigns in Nov-Dec 2016 and May-June 2017. Sampling took place from an inlet co-located with a sonic anemometer at 102 m on a meteorological tower in central Beijing. Analysis of the covariance between vertical wind speed and concentration enabled the calculation of emission flux, with an estimated footprint of between 2 - 5 km from the tower (which typically included some major ring roads and expressways). Fluxes were quantified using the continuous wavelet transformation (CWT) method, which enabled one minute resolved fluxes to be calculated. These data were compared to existing emissions estimates from the Multi-resolution Emission Inventory for China (MEIC). It is

  8. Cellular Phone Towers, Cell towers developed for Appraiser's Department in 2003. Location was based upon parcel centroids, and corrected to orthophotography. Probably includes towers other than cell towers (uncertain). Not published., Published in 2003, 1:1200 (1in=100ft) scale, Sedgwick County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Cellular Phone Towers dataset current as of 2003. Cell towers developed for Appraiser's Department in 2003. Location was based upon parcel centroids, and corrected...

  9. LBA-ECO CD-04 Biomass Survey, km 83 Tower Site, Tapajos National Forest, Brazil

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set contains the results of a biometric tree survey of a 19.25 ha area adjacent to the eddy flux tower at the km 83 logged forest tower site in...

  10. LBA-ECO CD-04 Biomass Survey, km 83 Tower Site, Tapajos National Forest, Brazil

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains the results of a biometric tree survey of a 19.25 ha area adjacent to the eddy flux tower at the km 83 logged forest tower site in Tapajos...

  11. LBA-ECO CD-04 Leaf Litter Data, km 83 Tower Site, Tapajos National Forest, Brazil

    Data.gov (United States)

    National Aeronautics and Space Administration — Above-ground litter productivity was measured in a 18 ha plot adjacent to the eddy flux tower at the logged forest tower site, km 83, Tapajos National Forest, Para,...

  12. LBA-ECO CD-04 Leaf Litter Data, km 83 Tower Site, Tapajos National Forest, Brazil

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: Above-ground litter productivity was measured in a 18 ha plot adjacent to the eddy flux tower at the logged forest tower site, km 83, Tapajos National...

  13. Exploring damping characteristics of composite tower of cable ...

    Indian Academy of Sciences (India)

    Two approaches are considered to define and investigate dynamic characteristics of a composite tower of cable-stayed bridges: The first approach makes use of a simplified approximation of two lumped masses to investigate the structure irregularity effects including damping of different material, mass ratio, frequency ratio ...

  14. SHINING TOWERS: THE EMBEDDED WORKS IN BAHIAN RECONCAVO CHURCHES

    Directory of Open Access Journals (Sweden)

    Fabiana Comerlato

    2014-03-01

    ornamentation was often used in the churches of Alagoas, while in Bahia, faience and other materials were introduced as a form of recycling, involving decorative patterns with a unique aesthetic approach in covering church towers in the nineteenth century.

  15. Constructing towers with skeletons from open Lie algebras and integrability

    Science.gov (United States)

    Palese, Marcella; Winterroth, Ekkehart

    2012-02-01

    We provide a given algebraic structure with the structure of an infinitesimal algebraic skeleton. The necessary conditions for integrability of the absolute parallelism of a tower with such a skeleton are dispersive nonlinear models and related conservation laws given in the form of associated linear spectral problems.

  16. Hausdorff gaps and towers in P(\\omega)/Fin

    Czech Academy of Sciences Publication Activity Database

    Borodulin-Nadzieja, P.; Chodounský, David

    2015-01-01

    Roč. 229, č. 3 (2015), s. 197-229 ISSN 0016-2736 R&D Projects: GA AV ČR IAA100190902 Institutional support: RVO:67985840 Keywords : Hausdorff gaps * special gaps * towers Subject RIV: BA - General Mathematics Impact factor: 0.553, year: 2015 http://journals.impan.pl/cgi-bin/doi?fm229-3-1

  17. Continuous measurements of methane from a tower network over Siberia

    Energy Technology Data Exchange (ETDEWEB)

    Sasakawa, M.; Machida, T.; Saeki, T.; Koyama, Y.; Maksyutov, S. (Center for Global Environmental Research, National Inst. for Environmental Studies, Tsukuba, Ibaraki (Japan)); Shimoyama, K. (Inst. of Low Temperature Science, Hokkaido Univ., Hokkaido (Japan)); Tsuda, N. (Global Environmental Forum, Tokyo (Japan)); Suto, H. (Japan Aerospace Exploration Agency (Japan)); Arshinov, M.; Davydov, D.; Fofonov, A.; Krasnov, O. (Inst. of Atmospheric Optics, Russian Academy of Sciences, Siberian Branch (Russian Federation))

    2010-11-15

    We have been conducting continuous measurements of Methane (CH{sub 4}) concentration from an expanding network of towers (JR-STATION: Japan-Russia Siberian Tall Tower Inland Observation Network) located in taiga, steppe and wetland biomes of Siberia since 2004. High daytime means (>2000 ppb) observed simultaneously at several towers during winter, together with in situ weather data and NCEP/NCAR reanalysis data, indicate that high pressure systems caused CH{sub 4} accumulation at subcontinental scale due to the widespread formation of an inversion layer. Daytime means sometimes exceeded 2000 ppb, particularly in the summer of 2007 when temperature and precipitation rates were anomalously high over West Siberia, which implies that CH{sub 4} emission from wetlands were exceptionally high in 2007. Many hot spots detected by MODIS in the summer of 2007 illustrate that the contribution of biomass burning also cannot be neglected. Daytime mean CH{sub 4} concentrations from the Siberian tower sites were generally higher than CH{sub 4} values reported at NOAA coastal sites in the same latitudinal zone, and the difference in concentrations between two sets of sites was reproduced with a coupled Eulerian-Lagrangian transport model. Simulations of emissions from different CH{sub 4} sources suggested that the major contributor to variation switched from wetlands during summer to fossil fuel during winter.

  18. Solar Power Tower Design Basis Document, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    ZAVOICO,ALEXIS B.

    2001-07-01

    This report contains the design basis for a generic molten-salt solar power tower. A solar power tower uses a field of tracking mirrors (heliostats) that redirect sunlight on to a centrally located receiver mounted on top a tower, which absorbs the concentrated sunlight. Molten nitrate salt, pumped from a tank at ground level, absorbs the sunlight, heating it up to 565 C. The heated salt flows back to ground level into another tank where it is stored, then pumped through a steam generator to produce steam and make electricity. This report establishes a set of criteria upon which the next generation of solar power towers will be designed. The report contains detailed criteria for each of the major systems: Collector System, Receiver System, Thermal Storage System, Steam Generator System, Master Control System, and Electric Heat Tracing System. The Electric Power Generation System and Balance of Plant discussions are limited to interface requirements. This design basis builds on the extensive experience gained from the Solar Two project and includes potential design innovations that will improve reliability and lower technical risk. This design basis document is a living document and contains several areas that require trade-studies and design analysis to fully complete the design basis. Project- and site-specific conditions and requirements will also resolve open To Be Determined issues.

  19. Atmospheric wet-type cooling tower with antifreeze system

    International Nuclear Information System (INIS)

    Coic, P.

    1985-01-01

    The cooling tower has air inlets at its base, a network of pipes which distributes the air to be cooled above the packing, and valves to isolate a part of the network. It includes also a bypass circuit, provided with means to control the flow rate fraction which is by-passed [fr

  20. Reliability Analysis of a Mono-Tower Platform

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Enevoldsen, I.; Sørensen, John Dalsgaard

    1990-01-01

    In this paper, a reliability analysis of a Mono-tower platform is presented. Te failure modes considered are yielding in the tube cross sections and fatigue failure in the butts welds. The fatigue failrue mode is investigated with a fatigue model, where the fatigue strength is expressed through SN...

  1. Solar tracking control tower; Steuerungstechnik folgt der Sonne

    Energy Technology Data Exchange (ETDEWEB)

    Leu, Andreas [Jetter AG, Ludwigsburg (Germany). Bereich technisches Marketing und Seminare

    2010-11-15

    The ''Gemue-Dome'' building at Waldzimmern is a unique industrial building. The research, development and innovation center has a rotary control tower equipped with solar cells which automatically tracks the sun. This automation task was a challenge for the control and power supply sections. (orig.)

  2. Wind Shear Characteristics at Central Plains Tall Towers (presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, M.; Elliott, D.

    2006-06-05

    The objectives of this report are: (1) Analyze wind shear characteristics at tall tower sites for diverse areas in the central plains (Texas to North Dakota)--Turbines hub heights are now 70-100 m above ground and Wind measurements at 70-100+ m have been rare. (2) Present conclusions about wind shear characteristics for prime wind energy development regions.

  3. Exploring damping characteristics of composite tower of cable ...

    Indian Academy of Sciences (India)

    SHEHATA E ABDEL RAHEEM

    Exploring damping characteristics of composite tower of cable-stayed bridges. SHEHATA E ABDEL RAHEEM1∗,2. 1Faculty of Engineering, Civil Engineering Department, Taibah University, Madinah 41411, P.O. 344, Saudia Arabia. 2Faculty of Engineering, Civil Engineering Department, Assiut University, Assiut 71516, ...

  4. Meteorological tower design for severe weather and remote locations

    Science.gov (United States)

    Kelly Elder; Ilkoo Angutikjuak; Jessica Baker; Matt Belford; Tom Bennett; Karl Birkeland; Daniel Bowker; Doug Chabot; April Cheuvront; Mark Dixon; Dylan Elder; Lee Elder; Shari Gearheard; Greg Giedt; Kim Grant; Sam Green; Ethan Greene; Nick Houfek; Caleb Huntington; Henry Huntington; Thomas Huntington; Daniel Janigian; Crane Johnson; Glen Liston; Rob Maris; Andrea Marsh; Hans-Peter Marshall; Aidan Meiners; Alex Meiners; Theo Meiners; Limakee Palluq; Josh Pope; Esa Qillaq; Joelli Sanguya; Sam Sehnert; Ron Simenhois; Banning Starr; Roger Tyler

    2012-01-01

    We have developed a robust meteorological tower for deployment in locations with extreme conditions and for applications that require relatively maintenance-free structures. The basic design consists of a triangular base with two horizontal rails on each side, and uprights at the triangle vertices for various instrument configurations. The fabrication materials include...

  5. Further investigation on the performance of a shower cooling tower

    International Nuclear Information System (INIS)

    Qi Xiaoni; Liu Zhenyan

    2008-01-01

    This study was prompted by the need to design towers for applications in which, due to salt deposition on the packing and subsequent blockage, the use of tower packing is not practical. In the previous model we presented [Qi Xiaoni, Liu Zhenyan, Li Dandan. Performance characteristics of a shower cooling tower. Energy Convers Manage 2007;48(1):193-203.], three critical assumptions were made to reduce the complexity and computational time, which can also reduce the models' accuracy. Accurate modelling of the operating process is a determining factor both for designing the shower cooling tower (SCT) and for optimising its operation. In this paper, we derive a new model without applying the three assumptions. According to the condition of the outlet air, the governing equations consider two cases, including the supersaturated and unsaturated states. This model is used to predict the performance of a full scale SCT located in China with different conditions for validation. The differences in the heat and mass transfer analyses of the two models are described at different atmospheric conditions

  6. Indiana State University Graduates to Advanced Plastic Cooling Towers

    Science.gov (United States)

    Sullivan, Ed

    2012-01-01

    Perhaps more than many other industries, today's universities and colleges are beset by dramatically rising costs on every front. One of the areas where overhead can be contained or reduced is in the operation of the chilled water systems that support air conditioning throughout college campuses, specifically the cooling towers. Like many…

  7. Towers of Function Fields over Non-prime Finite Fields

    DEFF Research Database (Denmark)

    Bassa, Alp; Beelen, Peter; Garcia, Arnaldo

    2015-01-01

    Over all non-prime finite fields, we construct some recursive towers of function fields with many rational places. Thus we obtain a substantial improvement on all known lower bounds for Ihara’s quantity A(ℓ), for ℓ = pn with p prime and n > 3 odd. We relate the explicit equations to Drinfeld modu...

  8. Galois towers over non-prime finite fields

    DEFF Research Database (Denmark)

    Bassa, Alp; Beelen, Peter; Garcia, Arnaldo

    2014-01-01

    In this paper we construct Galois towers with good asymptotic properties over any non-prime finite field Fℓ; i.e., we construct sequences of function fields N=(N1⊂N2⊂⋯) over Fℓ of increasing genus, such that all the extensions Ni/N1 are Galois extensions and the number of rational places of these...

  9. Exposure level from selected base station tower around Kuala Nerus

    African Journals Online (AJOL)

    Health risk due to RF radiation exposure from base station tower (BST) has been debated for years leading to public concerns. Thus, this preliminary study aims to measure, evaluate and analyze the exposure level on three selected BST around Kuala Nerus. The measurement of exposure level in terms of voltage ...

  10. Interception and retention of simulated cooling tower drift by vegetation

    International Nuclear Information System (INIS)

    Taylor, F.G. Jr.; Parr, P.D.

    1978-01-01

    A key issue concerning environmental impacts from cooling tower operation is the interception of drift by vegetation and the efficiency of plants in retaining the residue scavenged from the atmosphere. Chromated drift water, typical of the cooling towers of the Department of Energy's uranium enrichment facilities at Oak Ridge, Tennessee, was prepared using radio-labelled chromium. A portable aerosol generator was used to produce a spectrum of droplets with diameters (100 to 1300 μ) characteristic of cooling towers using state-of-the-art drift eliminators. Efficiency of interception by foliage varied according to leaf morphology with yellow poplar seedlings intercepting 72% of the deposition mass in contrast to 45% by loblolly pine and 24% by fescue grass. Retention patterns of intercepted deposition consisted of a short-time component (0 to 3 days) and a long-time component (3 to 63 days). Retention times, estimated from the regression equation of the long component, indicated that drift contamination from any deposition event may persist from between 8 and 12 weeks. In field situations adjacent to cooling towers, the average annual concentration of drift on vegetation at any distance remains relatively constant, with losses from weathering being compensated by chronic deposition

  11. An improved AODV routing protocol based on tower structure

    Directory of Open Access Journals (Sweden)

    Li Yong Qiang

    2016-01-01

    Full Text Available The paper proposed a new routing protocol(IAODV based on tower structure in the Ad Hoc network for the problem which Location Routing Protocol need hardware and Complex algorithm. By the simulation, The complexity of the new routing protocol is reduced without reducing the performance of the network.

  12. Simulation of control drives in a tower crane

    Directory of Open Access Journals (Sweden)

    Wojciech SOLARZ

    2011-01-01

    Full Text Available The design of a control system for a tower crane is investigated. Underlying the controller design is the theory of optimal linear control. Computer models of a crane and the control systems for the crane drives are developed. Simulation data reveals that the motion of the load can be effectively controlled so that it should follow a predetermined trajectory.

  13. CHARACTERISTICS OF SLUDGE BOTTOM MESH

    Directory of Open Access Journals (Sweden)

    Kamil Szydłowski

    2016-05-01

    Full Text Available The main aim of the study was to assess the selected heavy metals pollution of bottom sediments of small water bodies of different catchment management. Two ponds located in Mostkowo village were chosen for investigation. The first small water reservoir is surrounded by the cereal fields, cultivated without the use of organic and mineral fertilizers (NPK. The second reservoir is located in a park near rural buildings. Sediment samples were collected by the usage of KC Denmark sediments core probe. Samples were taken from 4 layers of sediment, from depth: 0–5, 5–10, 10–20 and 20–30 cm. Sampling was made once during the winter period (2014 year when ice occurred on the surface of small water bodies, from three points. The material was prepared for further analysis according to procedures used in soil science. The content of heavy metals (Cd, Cr, Cu, Ni, Pb and Zn were determined by atomic absorption spectrometry by usage of ASA ICE 3000 Thermo Scientific after prior digestion in the mixture (5: 1 of concentrated acids (HNO3 and HClO4. Higher pH values ​​were characteristic for sediments of pond located in a park than in pond located within the agricultural fields. In both small water bodies the highest heavy metal concentrations occurred in the deepest points of the research. In the sediments of the pond located within crop fields the highest concentration of cadmium, copper, lead and zinc were observed in a layer of 0–5 cm, wherein the nickel and chromium in a layer of 20–30 cm. In the sediments of the pond, located in the park the highest values ​​occurred at the deepest sampling point in the layer taken form 10–20 cm. Sediments from second reservoir were characterized by the largest average concentrations of heavy metals, except the lead content in sediment form the layer of 10–20 cm. According to the geochemical evaluation of sediments proposed by Bojakowska and Sokołowska [1998], the majority of samples belongs to Ist

  14. Upward streamers produced by a lightning strike to radio transmission towers

    Science.gov (United States)

    Krider, E. Philip; Wetmore, Ralph H.

    1987-01-01

    A lightning strike to the center of three 78-m radio transmission towers produced upward discharges with lengths of 40 and 79 m from each of the neighboring towers. This strike also caused a number of insulators on guy wires that supported the tower to flash over, and the locations of these points and the two-dimensional geometry of the discharge channels are projected onto a vertical plane that is centered on the tower.

  15. Pipeline bottoming cycle study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1980-06-01

    The technical and economic feasibility of applying bottoming cycles to the prime movers that drive the compressors of natural gas pipelines was studied. These bottoming cycles convert some of the waste heat from the exhaust gas of the prime movers into shaft power and conserve gas. Three typical compressor station sites were selected, each on a different pipeline. Although the prime movers were different, they were similar enough in exhaust gas flow rate and temperature that a single bottoming cycle system could be designed, with some modifications, for all three sites. Preliminary design included selection of the bottoming cycle working fluid, optimization of the cycle, and design of the components, such as turbine, vapor generator and condensers. Installation drawings were made and hardware and installation costs were estimated. The results of the economic assessment of retrofitting bottoming cycle systems on the three selected sites indicated that profitability was strongly dependent upon the site-specific installation costs, how the energy was used and the yearly utilization of the apparatus. The study indicated that the bottoming cycles are a competitive investment alternative for certain applications for the pipeline industry. Bottoming cycles are technically feasible. It was concluded that proper design and operating practices would reduce the environmental and safety hazards to acceptable levels. The amount of gas that could be saved through the year 2000 by the adoption of bottoming cycles for two different supply projections was estimated as from 0.296 trillion ft/sup 3/ for a low supply projection to 0.734 trillion ft/sup 3/ for a high supply projection. The potential market for bottoming cycle equipment for the two supply projections varied from 170 to 500 units of varying size. Finally, a demonstration program plan was developed.

  16. 14 CFR 170.13 - Airport Traffic Control Tower (ATCT) establishment criteria.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airport Traffic Control Tower (ATCT... AIR TRAFFIC CONTROL SERVICES AND NAVIGATIONAL FACILITIES Airport Traffic Control Towers § 170.13 Airport Traffic Control Tower (ATCT) establishment criteria. (a) The following criteria along with general...

  17. A new tower with good p-rank meeting Zink’s bound

    DEFF Research Database (Denmark)

    Anbar Meidl, Nurdagül; Beelen, Peter; Nguyen, Nhut

    2017-01-01

    In this article we investigate the asymptotic p-rank of a new tower of function fields defined over cubic finite fields. Its limit meets Zink's bound, but the new feature of this tower is that its asymptotic p-rank for small cubic finite fields is much smaller than that of other cubic towers for ...

  18. Progress on Concepts for Next-Generation Drop Tower Systems

    Science.gov (United States)

    Könemann, Thorben; Eigenbrod, Christian; Von Kampen, Peter; Laemmerzahl, Claus; Kaczmarczik, Ulrich

    2016-07-01

    The Center of Applied Space Technology and Microgravity (ZARM) founded by Prof. Dr.-Ing. Hans J. Rath in 1985 is part of the Department of Production Engineering at the University of Bremen, Germany. ZARM is mainly concentrated on fundamental investigations of gravitational and space-related phenomenas under conditions of weightlessness as well as questions and developments related to technologies for space. At ZARM about 100 scientists, engineers, and administrative staff as well as many students from different departments are employed. Today, ZARM is still one of the largest and most important research center for space sciences and technologies in Europe. With a height of 146 m the Bremen Drop Tower is the predominant facility of ZARM and also the only drop tower of its class in Europe. ZARM's ground-based laboratory offers the opportunity for daily short-term experiments under conditions of high-quality weightlessness at a level of 10-6 g (microgravity), which is one of the best achievable for ground-based flight opportunities. Scientists may choose up to three times a day between a single drop experiment with 4.74 s in simple free fall and an experiment in ZARM's worldwide unique catapult system with 9.3 s in weightlessness. Since the start of operation of the facility in 1990, over 7500 drops or catapult launches of more than 160 different experiment types from various scientific fields like fundamental physics, combustion, fluid dynamics, planetary formation / astrophysics, biology and materials sciences have been accomplished so far. In addition, more and more technology tests have been conducted under microgravity conditions at the Bremen Drop Tower in order to effectively prepare appropriate space missions in advance. In this paper we report on the progress on concepts for next-generation drop tower systems based on the GraviTower idea utilizing a guided electro-magnetic linear drive. Alternative concepts motivated by the scientific demand for higher

  19. Advanced power cycles and configurations for solar towers: Modeling and optimization of the decoupled solar combined cycle concept

    Science.gov (United States)

    García-Barberena, Javier; Olcoz, Asier; Sorbet, Fco. Javier

    2017-06-01

    CSP technologies are essential to allow large shares of renewables into the grid due to their unique ability to cope with the large variability of the energy resource by means of technically and economically feasible thermal energy storage (TES) systems. However, there is still the need and sought to achieve technological breakthroughs towards cost reductions and increased efficiencies. For this, research on advanced power cycles, like the Decoupled Solar Combined Cycle (DSCC) is, are regarded as a key objective. The DSCC concept is, basically, a Combined Brayton-Rankine cycle in which the bottoming cycle is decoupled from the operation of the topping cycle by means of an intermediate storage system. According to this concept, one or several solar towers driving a solar air receiver and a Gas Turbine (Brayton cycle) feed through their exhaust gasses a single storage system and bottoming cycle. This general concept benefits from a large flexibility in its design. On the one hand, different possible schemes related to number and configuration of solar towers, storage systems media and configuration, bottoming cycles, etc. are possible. On the other, within a specific scheme a large number of design parameters can be optimized, including the solar field size, the operating temperatures and pressures of the receiver, the power of the Brayton and Rankine cycles, the storage capacity and others. Heretofore, DSCC plants have been analyzed by means of simple steady-state models with pre-stablished operating parameters in the power cycles. In this work, a detailed transient simulation model for DSCC plants has been developed and is used to analyze different DSCC plant schemes. For each of the analyzed plant schemes, a sensitivity analysis and selection of the main design parameters is carried out. Results show that an increase in annual solar to electric efficiency of 30% (from 12.91 to 16.78) can be achieved by using two bottoming Rankine cycles at two different

  20. Bottom Scour Observed Under Hurricane Ivan

    National Research Council Canada - National Science Library

    Teague, William J; Jarosz, Eva; Keen, Timothy R; Wang, David W; Hulbert, Mark S

    2006-01-01

    Observations that extensive bottom scour along the outer continental shelf under Hurricane Ivan resulted in the displacement of more than 100 million cubic meters of sediment from a 35x15 km region...

  1. Contrastive analysis of cooling performance between a high-level water collecting cooling tower and a typical cooling tower

    Science.gov (United States)

    Wang, Miao; Wang, Jin; Wang, Jiajin; Shi, Cheng

    2018-02-01

    A three-dimensional (3D) numerical model is established and validated for cooling performance optimization between a high-level water collecting natural draft wet cooling tower (HNDWCT) and a usual natural draft wet cooling tower (UNDWCT) under the actual operation condition at Wanzhou power plant, Chongqing, China. User defined functions (UDFs) of source terms are composed and loaded into the spray, fill and rain zones. Considering the conditions of impact on three kinds of corrugated fills (Double-oblique wave, Two-way wave and S wave) and four kinds of fill height (1.25 m, 1.5 m, 1.75 m and 2 m), numerical simulation of cooling performance are analysed. The results demonstrate that the S wave has the highest cooling efficiency in three fills for both towers, indicating that fill characteristics are crucial to cooling performance. Moreover, the cooling performance of the HNDWCT is far superior to that of the UNDWCT with fill height increases of 1.75 m and above, because the air mass flow rate in the fill zone of the HNDWCT improves more than that in the UNDWCT, as a result of the rain zone resistance declining sharply for the HNDWCT. In addition, the mass and heat transfer capacity of the HNDWCT is better in the tower centre zone than in the outer zone near the tower wall under a uniform fill layout. This behaviour is inverted for the UNDWCT, perhaps because the high-level collection devices play the role of flow guiding in the inner zone. Therefore, when non-uniform fill layout optimization is applied to the HNDWCT, the inner zone increases in height from 1.75 m to 2 m, the outer zone reduces in height from 1.75 m to 1.5 m, and the outlet water temperature declines approximately 0.4 K compared to that of the uniform layout.

  2. Bottom production asymmetries at the LHC

    International Nuclear Information System (INIS)

    Norrbin, E.; Vogt, R.

    1999-01-01

    We present results on bottom hadron production asymmetries at the LHC within both the Lund string fragmentation model and the intrinsic bottom model. The main aspects of the models are summarized and specific predictions for pp collisions at 14 TeV are given. Asymmetries are found to be very small at central rapidities increasing to a few percent at forward rapidities. At very large rapidities intrinsic production could dominate but this region is probably out of reach of any experiment

  3. Bottom production asymmetries at the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Norrbin, E.; Vogt, R.

    1999-01-01

    We present results on bottom hadron production asymmetries at the LHC within both the Lund string fragmentation model and the intrinsic bottom model. The main aspects of the models are summarized and specific predictions for pp collisions at 14 TeV are given. Asymmetries are found to be very small at central rapidities increasing to a few percent at forward rapidities. At very large rapidities intrinsic production could dominate but this region is probably out of reach of any experiment.

  4. The optimal operation of cooling tower systems with variable-frequency control

    Science.gov (United States)

    Cao, Yong; Huang, Liqing; Cui, Zhiguo; Liu, Jing

    2018-02-01

    This study investigates the energy performance of chiller and cooling tower systems integrated with variable-frequency control for cooling tower fans and condenser water pumps. With regard to an example chiller system serving an office building, Chiller and cooling towers models were developed to assess how different variable-frequency control methods of cooling towers fans and condenser water pumps influence the trade-off between the chiller power, pump power and fan power under various operating conditions. The matching relationship between the cooling tower fans frequency and condenser water pumps frequency at optimal energy consumption of the system is introduced to achieve optimum system performance.

  5. Four Operational Strategies For The Tower of Pisa

    Science.gov (United States)

    Bartolozzi, F.

    The operational strategies proposed for safeguarding the Leaning Tower all agree on the urgent need to lay a sub-foundation for guaranteeing the stability of the foundation soil, considerably decreasing the current pressure to a value compatible with its resistance characteristics. Their second common property is the creation of a static beneficial effect on the material forming the monument. This effect may be achieved by reducing the pressure in the material forming the Tower, by making the present inclination decrease considerably, or by means of a reinforcement ring on the most stressed parts of the Tower - if the present inclination is to remain unchanged - or with the combined action of both the inclination decrease and the reinforcement ring. Clearly, the choice of each operation must be made within the framework of the present and particular resistance conditions of the material. On the other hand, the four techniques differ structurally and operationally. The former aspects refer to laying structural elements, all equally effective, but different in conception and function - such as pillars, beams, hinges and tubular devices ­ to be laid in order to integrate the common sub-foundation and to be utilised with respect to each operational technique. The operational differences mainly depend on the different executive needs with respect to the structural elements to be laid. The operational aspect of the fourth technique is very simple, but particularly delicate, as are all techniques concerning the Tower. In relation to this, the operation must clearly be managed by a highly qualified and professional group of technicians and workers using the most appropriate and modern technological apparatus. I believe that the considerable delicacy of the operational stage does not obstruct the application of the proposed techniques, both because of the precarious safety conditions of the building (requiring a radical solution), and because the operations put into

  6. Hard bottom substrate monitoring Horns Rev offshore wind farm. Annual status report 2003

    Energy Technology Data Exchange (ETDEWEB)

    Leonhard, S.B.; Pedersen, John

    2004-05-15

    Elsam and Eltra built the offshore demonstration wind farm at Horns Rev in the North Sea. Elsam is the owner and is responsible for the operation of the wind farm. Eltra is responsible for the connection of the wind farm to the national onshore grid. In the summer months of 2002, Elsam constructed the world's largest offshore wind farm off the Danish west coast. The wind farm is sited 14-20 km into the North Sea, west of Blaevands Huk. The first wind turbine was erected in May 2002 and the last wind turbine tower of a total of 80 was in place by August 2002. The construction work was completed with the last connecting cables sluiced down in September 2002. All the wind turbines were in production by December 2002. The expected impact of the wind farm will primarily be an alternation of habitats due to the introduction of hard bottom substrates as wind turbine towers and scour protections. A continuous development in the epifouling communities will be expected together with an introduction of new or alien species in the area. The indigenous benthic community in the area of Horns Rev can be characterised by infauna species belonging to the Goniadella-Spisula community. This community is typical of sandbanks in the North Sea area, although communities in such areas are very variable and site-specific. Character species used as indicators for environmental changes in the Horns Rev area are the bristle worms Goniadella bobretzkii, Ophelia borealis, Psione remota and Orbinia sertulata and the mussels Goodallia triangularis and Spisula solida. In connection with the implementation of the monitoring programme concerning the ecological impact of the introduction of hard substrate related to the Horns Rev Wind Farm, surveys on hard bottom substrate was conducted in March 2003 and in September 2003. This report describes the first year results of surveys on hard substrate after the completion of the offshore wind farm at Horns Rev. (au)

  7. Development of Active Learning Curriculum for CASPER's Microgravity Drop Tower

    Science.gov (United States)

    Carmona-Reyes, Jorge; Wang, Li; York, Judy; Matthews, Lorin; Laufer, Rene; Cook, Mike; Schmoke, Jimmy; Hyde, Truell

    2016-10-01

    As CASPER's new drop tower comes on line, plans for correlated educational research curricula are underway. CASPER's educational research team is working on developing curricula specific to the CASPER drop tower, modeled on a contest currently in use by (BEST) Robotics Inc. within central Texas independent school districts. The curricula integrates age specific use of computer programming software packages such as ``Scratch'' with industry standard communication protocols and augmented reality applications. Content is constructed around an earth and space science framework, covering subjects such as stars and galaxies, matter and energy, fusion and fission at a middle school level. CASPER faculty are partnering with the Region 12 Service Center; this combination provides a wide range of expertise that includes professional development, pedagogical methods, computational thinking in addition to microgravity and space science research expertise. The details of this work will be presented and samples of the manner in which it is impacting the CASPER research and educational outreach partnership will be discussed.

  8. A mathematical model for optimal tower crane layout planning

    Directory of Open Access Journals (Sweden)

    Mojtaba Hosseini

    2017-09-01

    Full Text Available Tower cranes, on today’s typical building construction sites, are the centerpiece of production, hoisting and transporting of a variety of loads. Due to a simple crane limited capacity; there is an urgent need to use high capacity cranes such as tower cranes. However, we have to select an appropriate type of cranes to be utilized to reduce the associated coste as much as possible. In this research, we propose a method to select the suitable type of crane and locate the best place for crane erection based on a minimum radius for requested crane and minimum cost. To fulfill the target, a computer program is designed to numerate these problems, demonstrating an example explaining how to apply the program and the results are discussed.

  9. Use of tower reactors for continuous ethanol production

    Directory of Open Access Journals (Sweden)

    M.C. Viegas

    2002-04-01

    Full Text Available The purpose of this work was to develop a continuous fermentation system operating with a tower reactor using some flocculent yeast strains isolated from an industrial process. The strain was an used in the trial of the proposed system, composed of two serial glass tower reactor. The effects of the following variables were studied on the yield and productivity of the system: total reducing sugar (TRS, concentration in feeding, recycle flow in the second reactor, residence time and diameter/height ratio of the reactors. It was observed that the TRS concentration in feeding and residence time is the variables that interfere most with the productivity of the system. Yield was not affected by any of the variables within the range of values studied. All trials were performed according to a factorial experimental design (making up a total of 19 trials and the results were evaluated by response surface.

  10. The Rock Island Clock Tower, From Ordnance to Engineers

    Science.gov (United States)

    1977-05-01

    11.) The Clock Tower shows no influence of two other architectural styles which were rapidly becoming popular in 1863: the Victor ian and gothic ...contrast to detailed specifications on modern architectural plans, the plans Major Kingsbury had to work with showed only the basic dimensions, together...sporadically. In 1930 storage was shifted to more modern facilities at the Arsenal. Just before or just after World War I (reports differ), the Army

  11. Natural-draught dry cooling tower for steam power plants

    International Nuclear Information System (INIS)

    Nasser, G.E.D.

    1977-01-01

    The problem of making natural-draught cooling towers for large steam power plants as simple, compact, and economical as possible can be solved by a combination of well-known structural features: The condenser elements, which are designed as stacks of plates with corrugated surfaces, are arranged in the form of a truncated pyramid enlarged at the top. In the cooling air flow, there are openings for feeding in superheated gas from the lower part of the cupola. (HP) [de

  12. A method to estimate the ageing of a cooling tower

    International Nuclear Information System (INIS)

    Barnel, Nathalie; Courtois, Alexis; Ilie, Petre-Lazar

    2006-09-01

    This paper deals with cooling towers ageing. Our contribution is a method to determine which part of on site measured strain we are able to predict by means of simulations. As a result, we map a gap indicator on the structure. Calculations have been performed in three configurations. Comparing the values obtained in the three cases helps to determine which researches are worth to be done. Indeed, gap indicator reveals that: - THM can not be considered as the main and only ageing mechanism, so long as tower older than 10 years are examined. At least creep has to be taken into account too; - Gap indicator is sensitive to initial hydration conditions. Drying process before bringing into service should be estimated properly, taking into account the different construction steps; - Comparing different thermal conditions reveals that meteorological conditions have a significant influence on results. So, it will be interesting to differentiate the sunny and the shaded part of the tower when the measurements are done; - A large part of the values obtained can be explicated by construction defects. A study on this particular problematic seems to be essential. The four items mentioned must be considered as perspectives to improve the present method of simulations. (authors)

  13. Humidification tower for humid air gas turbine cycles: Experimental analysis

    International Nuclear Information System (INIS)

    Traverso, A.

    2010-01-01

    In the HAT (humid air turbine) cycle, the humidification of compressed air can be provided by a pressurised saturator (i.e. humidification tower or saturation tower), this solution being known to offer several attractive features. This work is focused on an experimental study of a pressurised humidification tower, with structured packing. After a description of the test rig employed to carry out the measuring campaign, the results relating to the thermodynamic process are presented and discussed. The experimental campaign was carried out over 162 working points, covering a relatively wide range of possible operating conditions. It is shown that the saturator behaviour, in terms of air outlet humidity and temperature, is primarily driven by, in decreasing order of relevance, the inlet water temperature, the inlet water over inlet dry air mass flow ratio and the inlet air temperature. The exit relative humidity is consistently over 100%, which may be explained partially by measurement accuracy and droplet entrainment, and partially by the non-ideal behaviour of air-steam mixtures close to saturation. Experimental results have been successfully correlated using a set of new non-dimensional groups: such a correlation is able to capture the air outlet temperature with a standard deviation σ = 2.8 K.

  14. Optimization design of solar enhanced natural draft dry cooling tower

    International Nuclear Information System (INIS)

    Zou, Zheng; Guan, Zhiqiang; Gurgenci, Hal

    2013-01-01

    Highlights: • We proposed a cost model for solar enhanced natural draft dry cooling tower. • We proposed an optimization scheme for this new cooling system. • We optimally designed one for a 50 MW EGS geothermal plant as a demonstration. • Results proved its economic advantages for EGS geothermal application. - Abstract: This paper proposed an optimization scheme for solar enhanced natural draft dry cooling tower design, in which a detailed cost model was proposed including capital, labour, maintenance and operation costs of each component. Based on the developed cost model, the optimal design option can be identified in terms of the relatively lower annual cost and the relatively higher total extra income over the Solar Enhanced Natural Draft Dry Cooling Tower (SENDDCT) lifetime. As a case study, a SENDDCT was optimally designed to meet the cooling demand for a 50 MW geothermal power plant with Engineered Geothermal System (EGS) technology. The results showed that the optimized SENDDCT not only has better cooling performance during the daytime but also is a cost effective option for EGS geothermal power plants

  15. Calculating the evaporated water flow in a wet cooling tower

    International Nuclear Information System (INIS)

    Grange, J.L.

    1994-04-01

    On a cooling tower, it is necessary to determine the evaporated water flow in order to estimate the water consumption with a good accuracy according to the atmospheric conditions, and in order to know the characteristics of the plume. The evaporated flow is small compared to the circulating flow. A direct measurement is very inaccurate and cannot be used. Only calculation can give a satisfactory valuation. The two usable theories are the Merkel's one in which there are some simplifying assumptions, and the Poppe's one which is more exact. Both theories are used in the numerical code TEFERI which has been developed and is run by Electricite de France. The results obtained by each method are compared and validated by measurements made in the hot air of a cooling tower. The consequences of each hypothesis of Merkel's theory are discussed. This theory does not give the liquid water content in the plume and it under-estimates the evaporated flow all the lower the ambient temperature is. On the other hand, the Poppe's method agrees very closely with the measurements as well for the evaporated flow than for the liquid water concentration. This method is used to establish the specific consumption curves of the great nuclear plants cooling towers as well as to calculate the emission of liquid water drops in the plumes. (author). 11 refs., 9 figs

  16. Optimum Tower Crane Selection and Supporting Design Management

    Directory of Open Access Journals (Sweden)

    Hyo Won Sohn

    2014-08-01

    Full Text Available To optimize tower crane selection and supporting design, lifting requirements (as well as stability should be examined, followed by a review of economic feasibility. However, construction engineers establish plans based on data provided by equipment suppliers since there are no tools with which to thoroughly examine a support design's suitability for various crane types, and such plans lack the necessary supporting data. In such cases it is impossible to optimize a tower crane selection to satisfy lifting requirements in terms of cost, and to perform lateral support and foundation design. Thus, this study is intended to develop an optimum tower crane selection and supporting design management method based on stability. All cases that are capable of generating an optimization of approximately 3,000 ˜ 15,000 times are calculated to identify the candidate cranes with minimized cost, which are examined. The optimization method developed in the study is expected to support engineers in determining the optimum lifting equipment management.

  17. Surface sediment characteristics and tower karst dissolution, Guilin, southern China

    Science.gov (United States)

    Tang, Tao

    2003-01-01

    Dissolution of extensive outcrops of limestone and dolostone in humid tropical and subtropical southern China produced numerous caves and residual hills that are referred as tower karst. This study identifies and relates the physical and chemical characteristics of the surface sediment with the limestone bedrock in Guilin to assess the influence of the limestone dissolution process on sediment composition. The results of this study indicated that (i) both limestone and dolostone of the region are very pure (99.5% and 98.5% of CaCO 3 and MgCO 3, respectively); (ii) the material composition of limestone and dolostone is different from that of soil and sediment of the region: constituents of surface sediments are highly related with the clastic sedimentary rocks, such as the mudstone, but show negative correlation with limestone and dolostone; (iii) the limestone formations are highly resistant to physical weathering and disintegration; their durability versus physical weathering and their high susceptibility to chemical dissolution account for why residual towers can form and persist; (iv) a dual-zone environmental structure exists vertically downward from the surface in Guilin: the zone of unconsolidated clastic sediments that is predominantly acidic, and the zone of karstified limestone that is predominantly basic. The evidence suggests that the environment and processes differ in these two zones. The chemical dissolution of limestone that formed tower karst of the region is not mainly responsible for the accumulation of clastic sediment on the surface.

  18. A 22 MW pilot plant with an ammonia bottoming cycle is being tested by Electricite de France

    International Nuclear Information System (INIS)

    Fleury, J.; Bellot, C.

    1989-01-01

    EDF's DER has built a 22 MW ammonia bottoming cycle pilot power plant in Gennevilliers near Paris. This construction marks a turning point in the development of bottoming cycles which was undertaken at EDF in 1970. These cycles could be used in powerful PWR plants. The key feature of this type of plant is its appreciable capacity gain when the temperature of the heat sink drops. Thus, with a heat sink of the dry cooling tower type, low air temperatures in winter can be turned to use to produce more energy when demand is at its highest. At the same time, with dry cooling towers, a tiresome constraint vanishes since the plant location choice does no longer depend on the existence of a water reservoir in the vicinity of the plant. The construction of the pilot plant Cybiam began in 1980. Its steam turbine-generator set was coupled to the French network in March 1986 and its ammonia turbine-generator set in December 1986. The full load was attained on June 4th 1987. The main problems met during its commissioning are described in this paper as well as the first test results. From the economic point of view, the money value of the extra power generated during cold spells is assessed

  19. Bottom-of-sulcus dysplasia: imaging features.

    Science.gov (United States)

    Hofman, Paul A M; Fitt, Gregory J; Harvey, A Simon; Kuzniecky, Ruben I; Jackson, Graeme

    2011-04-01

    Dysplasia at the bottom of a sulcus is a subtle but distinct malformation of cortical development relevant to epilepsy. The purpose of this study was to review the imaging features important to the clinical diagnosis of this lesion. All cases recognized as typical bottom-of-sulcus dysplasia in our comprehensive epilepsy program over the period 2002-2007 were included in the study. In the 20 cases recognized, three major features were identified: cortical thickening at the bottom of a sulcus; a funnel-shaped extension of the lesion toward the ventricular surface, commonly with abnormal signal intensity; and an abnormal gyral pattern related to the bottom-of-sulcus dysplasia, sometimes with a puckered appearance. The pathologic features of the resected lesions were typical of focal cortical dysplasia. Bottom-of-sulcus dysplasia is a distinctive malformation of cortical development that can be diagnosed on the basis of imaging characteristics. Reliable identification of this type of malformation of cortical development is difficult but clinically important because the lesion appears to be highly epileptogenic and because the prognosis for seizure control is excellent after focal resection.

  20. Coal Bottom Ash for Portland Cement Production

    Directory of Open Access Journals (Sweden)

    Cristina Argiz

    2017-01-01

    Full Text Available Because of industrialization growth, the amount of coal power plant wastes has increased very rapidly. Particularly, the disposal of coal bottom ash (CBA is becoming an increasing concern for many countries because of the increasing volume generated, the costs of operating landfill sites, and its potential hazardous effects. Therefore, new applications of coal bottom ash (CBA have become an interesting alternative to disposal. For instance, it could be used as a Portland cement constituent leading to more sustainable cement production by lowering energy consumption and raw material extracted from quarries. Coal fly and bottom ashes are formed together in the same boiler; however, the size and shape of these ashes are very different, and hence their effect on the chemical composition as well as on the mineralogical phases must be studied. Coal bottom ash was ground. Later, both ashes were compared from a physical, mechanical, and chemical point of view to evaluate the potential use of coal bottom ash as a new Portland cement constituent. Both ashes, produced by the same electrical power plant, generally present similar chemical composition and compressive strength and contribute to the refill of mortar capillary pores with the reaction products leading to a redistribution of the pore size.

  1. Tall towers for large wind turbines. Report from Vindforsk project V-342

    Energy Technology Data Exchange (ETDEWEB)

    Engstroem, Staffan; Lyrner, Tomas; Hassanzadeh, Manouchehr; Stalin, Thomas; Johansson, John

    2010-07-15

    The general rule of thumb has been to furnish a wind turbine with a tower as tall as the turbine diameter, with deviations downwards for high wind speed sites. In this report the statement is questioned, with special emphasis for wind turbines sited in forests. The aim of this project was to propose and calculate candidate types of tall towers for on-shore wind turbines in the 3 - 5 MW range, with special reference to siting in forests with a representative wind shear. During the project this scope has been more precisely defined to study 3 and 5 MW wind turbines with hub heights of 80 - 175 meters featuring the following tower solutions: 1. Steel shell tower designed in a conventional way with flanges and both longitudinal and transverse welds. 2. Steel shell tower with bolted friction joints only. 3. Concrete tower with pretensioned steel tendons. 4. Hybrid tower with a lower concrete part and an upper part built as a conventional steel shell. 5. Lattice tower. 6. Wooden tower. During the execution of the project the design of a total of 42 towers was outlined and calculated. Today the welded steel shell tower dominates the wind turbine market. Larger turbines and higher hub heights result in larger optimal tower base diameters. For the road transportation there are limitations due to bridges and other obstacles. In Sweden the limit for transports with special permits in general maximizes the diameter to 4,5 metres. To some extent it is still technically possible to build towers with a less than optimal diameter, but due to the high mass and the large wall thickness they tend to be uneconomical in comparison with other alternatives above a hub height of roughly 100 metres. In this report welded steel shell towers were outlined for 3 MW turbines up to a hub height of 150 metres whereas the limit for the 5 MW towers was 100 metres. When diameter restrictions tend to make welded towers uneconomical, the next logical choice is steel shell towers with bolted friction

  2. Assessing the Gap Between Top-down and Bottom-up Measured Methane Emissions in Indianapolis, IN.

    Science.gov (United States)

    Prasad, K.; Lamb, B. K.; Cambaliza, M. O. L.; Shepson, P. B.; Stirm, B. H.; Salmon, O. E.; Lavoie, T. N.; Lauvaux, T.; Ferrara, T.; Howard, T.; Edburg, S. L.; Whetstone, J. R.

    2014-12-01

    Releases of methane (CH4) from the natural gas supply chain in the United States account for approximately 30% of the total US CH4 emissions. However, there continues to be large questions regarding the accuracy of current emission inventories for methane emissions from natural gas usage. In this paper, we describe results from top-down and bottom-up measurements of methane emissions from the large isolated city of Indianapolis. The top-down results are based on aircraft mass balance and tower based inverse modeling methods, while the bottom-up results are based on direct component sampling at metering and regulating stations, surface enclosure measurements of surveyed pipeline leaks, and tracer/modeling methods for other urban sources. Mobile mapping of methane urban concentrations was also used to identify significant sources and to show an urban-wide low level enhancement of methane levels. The residual difference between top-down and bottom-up measured emissions is large and cannot be fully explained in terms of the uncertainties in top-down and bottom-up emission measurements and estimates. Thus, the residual appears to be, at least partly, attributed to a significant wide-spread diffusive source. Analyses are included to estimate the size and nature of this diffusive source.

  3. High Flux Isotopes Reactor (HFIR) Cooling Towers Demolition Waste Management

    International Nuclear Information System (INIS)

    Pudelek, R. E.; Gilbert, W. C.

    2002-01-01

    This paper describes the results of a joint initiative between Oak Ridge National Laboratory, operated by UT-Battelle, and Bechtel Jacobs Company, LLC (BJC) to characterize, package, transport, treat, and dispose of demolition waste from the High Flux Isotope Reactor (HFIR), Cooling Tower. The demolition and removal of waste from the site was the first critical step in the planned HFIR beryllium reflector replacement outage scheduled. The outage was scheduled to last a maximum of six months. Demolition and removal of the waste was critical because a new tower was to be constructed over the old concrete water basin. A detailed sampling and analysis plan was developed to characterize the hazardous and radiological constituents of the components of the Cooling Tower. Analyses were performed for Resource Conservation and Recovery Act (RCRA) heavy metals and semi-volatile constituents as defined by 40 CFR 261 and radiological parameters including gross alpha, gross beta, gross gamma, alpha-emitting isotopes and beta-emitting isotopes. Analysis of metals and semi-volatile constituents indicated no exceedances of regulatory limits. Analysis of radionuclides identified uranium and thorium and associated daughters. In addition 60Co, 99Tc, 226Rm, and 228Rm were identified. Most of the tower materials were determined to be low level radioactive waste. A small quantity was determined not to be radioactive, or could be decontaminated. The tower was dismantled October 2000 to January 2001 using a detailed step-by-step process to aid waste segregation and container loading. The volume of waste as packaged for treatment was approximately 1982 cubic meters (70,000 cubic feet). This volume was comprised of plastic (∼47%), wood (∼38%) and asbestos transite (∼14%). The remaining ∼1% consisted of the fire protection piping (contaminated with lead-based paint) and incidental metal from conduit, nails and braces/supports, and sludge from the basin. The waste, except for the

  4. Research on Condition Assessment Method of Transmission Tower Under the Action of Strong Wind

    Science.gov (United States)

    Huang, Ren-mou; An, Li-qiang; Zhang, Rong-lun; Wu, Jiong; Liang, Ya-feng

    2018-03-01

    Transmission towers are often subjected to the external damage of severe weather like strong wind and so on, which may cause the collapse due to the yield and fracture of the tower material. Aiming this issue, an assessment method was proposed in this paper to assess the operation condition of transmission towers under strong wind. With a reasonable assess index system established firstly, then the internal force of the tower material was solved and its stability was determined through the mechanical analysis of the transmission tower finite element model. Meanwhile, the condition risk level of the tower was finally determined by considering the difference among the influences of other factors like corrosion and loose of members, slope on the transmission tower through the analytic hierarchy process. The assessment method was applied to assess the wind-induced collapse of towers in 110kV Bao Yi II line in Wenchang City, Hainan Province, of which the result proves the method can assess the condition of transmission tower under strong wind and of guiding significance for improving the windproof capability of transmission towers.

  5. Origin and prevention of infection with Legionella pneumophila through cooling towers and evaporative cooling towers; Entstehung und Vermeidung von Legionelleninfektionen durch Kuehltuerme und Rueckkuehlwerke

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Roebbecke, R. [Bonn Univ. (Germany). Hygiene-Institut; Richter, M. [Staatshochbauamt, Bonn (Germany)

    1994-04-01

    Evaporative cooling towers and industrial ventilator cooling towers have repeatedly been described as the origin of Legionnaires` disease. This article describes the design and function of cooling towers and evaporative cooling towers, sums up knowledge on the colonization of such systems with Legionella pneumophila, and describes conditions permitting the transmission of Legionella. Furthermore, design, maintenance, cleaning and disinfection measures are indicated which are believed to reduce the risk of infection through industrial and evaporative cooling towers. (orig.) [Deutsch] Rueckkuehlwerke klimatechnischer Anlagen und industrielle Ventilator-Kuehltuerme sind mehrfach als Ausgangspunkt von Legionellose-Epidemien beschrieben worden. In der vorliegenden Arbeit werden Aufbau und Funktion von Kuehltuermen und Rueckkuehlwerken erlaeutert, Erkenntnisse ueber die Besiedlung dieser Anlagen mit Legionellen zusammengefassten und die Situationen geschildert, in denen es zur Uebertragung von Legionellen kam. Darueber hinaus werden Konstruktions-, Wartungs-, Reinigungs-, und Desinfektionsmassnahmen aufgefuehrt, die zur Verminderung des Infektionsrisikos durch Kuehltuerme und Rueckkuehlwerke als wirksam angesehen werden. (orig.)

  6. Penggunaan Bottom Ash Sebagai Pengganti Agregat Halus Pada Mortar Hvfa

    OpenAIRE

    Sulistio, Aldi Vincent; Wahjudi, Samuel; Hardjito, Djwantoro; Antoni, Antoni

    2016-01-01

    Bottom ash adalah material limbah PLTU yang melimpah dan kurang dimanfaatkan. Terdapat potensi pemanfaatan bottom ash sebagai agregat halus dalam campuran beton. Dalam penelitian ini, bottom ash diberi treatment ayak dan tumbuk untuk digunakan sebagai pengganti pasir dalam campuran beton. Hal pertama yang dilakukan adalah pengujian karateristik fisik dan kimiawi dari bottom ash. Dilakukan pengujian water content, sieve analysis, fineness modulus, dan berat isi dari pasir dan bottom ash yang d...

  7. Investigation on Shielding Failure of a Novel 400 kV Composite tower

    DEFF Research Database (Denmark)

    Wang, Qian; Jahangiri, Tohid; Bak, Claus Leth

    2018-01-01

    In this paper, the lightning shielding performance of a newly-designed 400 kV double-circuit composite tower is investigated. Based on a revised EGM method, traditional shielding failure regions, located at both sides of a traditional tower is no longer a big issue for the fully composite tower......, due to its unusual ‘Y’ configuration. Instead, a new unprotected region exists in the tower center. The maximum lightning current that can lead to shielding failure and the shielding failure rate (SFR) of the new tower are calculated. To verify results from the revised EGM method, a scale model test...... is conducted. Spatial shielding failure probability around the tower is calculated based on ratio of discharge paths recorded in the test. Moreover, based on test results, the maximum shielding failure lightning currents are obtained. Analysis and results derived from the revised EGM method and scale model...

  8. Visibility analysis of fire lookout towers in the Boyabat State Forest Enterprise in Turkey.

    Science.gov (United States)

    Kucuk, Omer; Topaloglu, Ozer; Altunel, Arif Oguz; Cetin, Mehmet

    2017-07-01

    For a successful fire suppression, it is essential to detect and intervene forest fires as early as possible. Fire lookout towers are crucial assets in detecting forest fires, in addition to other technological advancements. In this study, we performed a visibility analysis on a network of fire lookout towers currently operating in a relatively fire-prone region in Turkey's Western Black Sea region. Some of these towers had not been functioning properly; it was proposed that these be taken out of the grid and replaced with new ones. The percentage of visible areas under the current network of fire lookout towers was 73%; it could rise to 81% with the addition of newly proposed towers. This study was the first research to conduct a visibility analysis of current and newly proposed fire lookout towers in the Western Black Sea region and focus on its forest fire problem.

  9. A two staged condensation of vapors of an isobutane tower in installations for sulfuric acid alkylation

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, N.P.; Feyzkhanov, R.I.; Idrisov, A.D.; Navalikhin, P.G.; Sakharov, V.D.

    1983-01-01

    In order to increase the concentration of isobutane to greater than 72 to 76 percent in an installation for sulfuric acid alkylation, a system of two staged condensation of vapors from an isobutane tower is placed into operation. The first stage condenses the heavier part of the upper distillate of the tower, which is achieved through somewhat of an increase in the condensate temperature. The product which is condensed in the first stage is completely returned to the tower as a live irrigation. The vapors of the isobutane fraction which did not condense in the first stage are sent to two newly installed condensers, from which the product after condensation passes through intermediate tanks to further depropanization. The two staged condensation of vapors of the isobutane tower reduces the content of the inert diluents, the propane and n-butane in the upper distillate of the isobutane tower and creates more favorable conditions for the operation of the isobutane and propane tower.

  10. 49 CFR 179.200-13 - Manway ring or flange, pressure relief device flange, bottom outlet nozzle flange, bottom washout...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Manway ring or flange, pressure relief device flange, bottom outlet nozzle flange, bottom washout nozzle flange and other attachments and openings. 179....200-13 Manway ring or flange, pressure relief device flange, bottom outlet nozzle flange, bottom...

  11. A resting bottom sodium cooled fast reactor

    International Nuclear Information System (INIS)

    Costes, D.

    2012-01-01

    This follows ICAPP 2011 paper 11059 'Fast Reactor with a Cold Bottom Vessel', on sodium cooled reactor vessels in thermal gradient, resting on soil. Sodium is frozen on vessel bottom plate, temperature increasing to the top. The vault cover rests on the safety vessel, the core diagrid welded to a toric collector forms a slab, supported by skirts resting on the bottom plate. Intermediate exchangers and pumps, fixed on the cover, plunge on the collector. At the vessel top, a skirt hanging from the cover plunges into sodium, leaving a thin circular slit partially filled by sodium covered by argon, providing leak-tightness and allowing vessel dilatation, as well as a radial relative holding due to sodium inertia. No 'air conditioning' at 400 deg. C is needed as for hanging vessels, and this allows a large economy. The sodium volume below the slab contains isolating refractory elements, stopping a hypothetical corium flow. The small gas volume around the vessel limits any LOCA. The liner cooling system of the concrete safety vessel may contribute to reactor cooling. The cold resting bottom vessel, proposed by the author for many years, could avoid the complete visual inspection required for hanging vessels. However, a double vessel, containing support skirts, would allow introduction of inspecting devices. Stress limiting thermal gradient is obtained by filling secondary sodium in the intermediate space. (authors)

  12. Spectroscopy and decays of charm and bottom

    International Nuclear Information System (INIS)

    Butler, J.N.

    1997-10-01

    After a brief review of the quark model, we discuss our present knowledge of the spectroscopy of charm and bottom mesons and baryons. We go on to review the lifetimes, semileptonic, and purely leptonic decays of these particles. We conclude with a brief discussion B and D mixing and rare decays

  13. Police reform from the bottom up

    African Journals Online (AJOL)

    Over the past two decades the theories and strategies associated with institutional reform of the police as public agency have been a source of invigoration for ... Criminology, Faculty of Law at the University of Cape. Town. Elrena van der Spuy*. Elrena.vanderspuy@uct.ac.za. Title: Police reform from the bottom up: officers ...

  14. Bottomonia: open bottom strong decays and spectrum

    Directory of Open Access Journals (Sweden)

    Santopinto E.

    2014-05-01

    Full Text Available We present our results for the bottomonium spectrum with self energy corrections. The bare masses used in the calculation are computed within Godfrey and Isgur’s relativized quark model. We also discuss our results for the open bottom strong decay widths of higher bottomonia in the 3P0 pair-creation model.

  15. There's Plenty of Room at the Bottom

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 16; Issue 9. There's Plenty of Room at the Bottom. Richard P Feynman. Classics Volume 16 Issue 9 September 2011 pp 890-905. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/016/09/0890-0905 ...

  16. Bottom fauna of the Malacca Strait

    Digital Repository Service at National Institute of Oceanography (India)

    Parulekar, A.H.; Ansari, Z.A.

    Bottom fauna of Malacca Strait (connecting the Indian Ocean with Pacific) in the depth range of 80 to 1350 m, is dominated by meiofauna which exceeds macrofauna by 12.5 times in weight and by more than 780 times in population density. Standing crop...

  17. Production efficiency of mussel bottom culture

    NARCIS (Netherlands)

    Capelle, Jacob J.

    2017-01-01

    Mussel bottom culture is an extensive type of aquaculture; it depends on natural resources for feed, seed and space. It consists of the translocation of seed from natural beds to designed culture areas, where mussel farmers try to improve production efficiency. Production efficiency is measured by

  18. Influence of execution tolerances for friction connections in circular and polygonal towers for wind converters

    OpenAIRE

    Heistermann, Christine; Pavlovic, M.; Veljkovic, M.; Pak, Daniel; Feldmann, Markus; Rebelo, Carlos; da Silva, Luís Simões

    2017-01-01

    Friction connections with long open slotted holes have been proven to be a competitive alternative to the conventional flange connections in steel tubular towers for wind energy converters. As full-scale tests are not available, results of Finite Element Analysis (FEA) of the real-scale tower geometry are used in this paper to investigate the influence of tower cross section shape, execution tolerance (gap between the shells) and length of the connection on the bending resistance. Buckling be...

  19. Tokyo Tower and Tokyo Skytree: History and Symbolism in Contemporary Japan

    OpenAIRE

    Yunuen Ysela Mandujano-Salazar

    2016-01-01

    The Tokyo Tower and the Tokyo Skytree are the two most recognizable landmarks on the skyline of Japan’s capital. By means of a documental revision, a textual interpretative analysis of media contents, participant observation and unstructured interviews, the objective of this article is to identify the development of these towers as symbols of Tokyo and Japan. It is found that, with more than half a century of existence, the Tokyo Tower represents the successful post-war Japanese society, whil...

  20. Surface and Tower Meteorological Instrumentation at Atqasuk (METTWR2H) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Ritsche, MT

    2006-01-01

    The Atqasuk meteorology station (AMET) uses mainly conventional in situ sensors to measure wind speed, wind direction, air temperature, dew point, and humidity mounted on a 10-m tower. It also obtains barometric pressure, visibility and precipitation data from sensors at or near the base of the tower. In addition, a chilled mirror hygrometer (CMH) is located at 1 m for comparison purposes. Temperature and relative humidity (RH) probes are mounted at 2 m and 5 m on the tower.

  1. Atmospheric extinction in simulation tools for solar tower plants

    Science.gov (United States)

    Hanrieder, Natalie; Wilbert, Stefan; Schroedter-Homscheidt, Marion; Schnell, Franziska; Guevara, Diana Mancera; Buck, Reiner; Giuliano, Stefano; Pitz-Paal, Robert

    2017-06-01

    Atmospheric extinction causes significant radiation losses between the heliostat field and the receiver in a solar tower plants. These losses vary with site and time. State of the art is that in ray-tracing and plant optimization tools, atmospheric extinction is included by choosing between few constant standard atmospheric conditions. Even though some tools allow the consideration of site and time dependent extinction data, such data sets are nearly never available. This paper summarizes and compares the most common model equations implemented in several ray-tracing tools. There are already several methods developed and published to measure extinction on-site. An overview of the existing methods is also given here. Ray-tracing simulations of one exemplary tower plant at the Plataforma Solar de Almería (PSA) are presented to estimate the plant yield deviations between simulations using standard model equations instead of extinction time series. For PSA, the effect of atmospheric extinction accounts for losses between 1.6 and 7 %. This range is caused by considering overload dumping or not. Applying standard clear or hazy model equations instead of extinction time series lead to an underestimation of the annual plant yield at PSA. The discussion of the effect of extinction in tower plants has to include overload dumping. Situations in which overload dumping occurs are mostly connected to high radiation levels and low atmospheric extinction. Therefore it can be recommended that project developers should consider site and time dependent extinction data especially on hazy sites. A reduced uncertainty of the plant yield prediction can significantly reduce costs due to smaller risk margins for financing and EPCs. The generation of extinction data for several locations in form of representative yearly time series or geographical maps should be further elaborated.

  2. Drop Tower Experiments concerning Fluid Management under Microgravity

    Science.gov (United States)

    Gaulke, Diana; Dreyer, Michael

    2012-07-01

    Transport and positioning of liquid under microgravity is done utilizing capillary forces. Therefore, capillary transport processes have to be understood for a wide variety of space applications, ranging from propellant management in tanks of space transportation systems to eating and drinking devices for astronauts. There are two types of liquid transportation in microgravity using capillary forces. First, the driven liquid flow in open channels where the capillary forces at free surfaces ensure a gas and vapor free flow. Here it is important to know the limiting flow rate through such an open channel before the free surface collapses and gas is sucked into the channel. A number of different experiments at the drop tower Bremen, on sounding rockets and at the ISS have been conducted to analyse this phenomenon within different geometries. As result a geometry dependent theory for calculating the maximum flow rate has been found. On the other hand liquid positioning and transportation requires the capillary pressure of curved surfaces to achieve a liquid flow to a desired area. Especially for space applications the weight of structure has to be taken into account for development. For example liquid positioning in tanks can be achieved via a complicated set of structure filling the whole tank resulting in heavy devices not reasonable in space applications. Astrium developed in cooperation with ZARM a propellant management device much smaller than the tank volume and ensuring a gas and vapour free supply of propellant to the propulsion system. In the drop tower Bremen a model of this device was tested concerning different microgravity scenarios. To further decrease weight and ensure functionality within different scenarios structure elements are designed as perforated geometries. Capillary transport between perforated plates has been analyzed concerning the influence of geometrical pattern of perforations. The conducted experiments at the drop tower Bremen show the

  3. How to Make a Microgravity Drop Tower for Your Classroom

    Science.gov (United States)

    DeLombard, Richard; Hall, Nancy R.

    2014-01-01

    Microgravity is quite often seen as exotic and special as astronauts float around in the International Space Station, eating MM's in mid-air, and performing science experiments, all done seemingly without gravity being present. Surprisingly enough, up on the ISS there is about 90 of the same gravity that holds you to the floor in your classroom or museum exhibit hall. Participate in this session and you will understand that and more. You can use simple devices to demonstrate microgravity conditions in your classroom or museum exhibit hall. This will be the same microgravity condition that astronauts experience on the ISS, just for a much shorter period of time. Contrary to popular opinion of some people, microgravity is NOT caused by zero gravity up there. Microgravity on the ISS is due to free fall within the Earth's gravitational field. That means you can drop an item in free fall in your classroom and museum exhibit hall and that item will experience microgravity. In this session, a short theory segment will explain and reinforce these concepts so that you may explain to others. The session will concentrate on showing the session participants how to make an effective, but inexpensive, drop tower for use in the classroom. Such a drop tower may be used to reinforce classroom instruction in physics and forces motion as well as serve as a platform for student investigations, classroom competitions, and student science or technology fair entries. Session participants will build their own simple microgravity experiment and operate them in a drop tower, compare results, and modify their experiment based on results. This material is also useful for public demonstrations at school open houses, travelling museum exhibits, fixed museum exhibits, and independent student projects or experiments. These free fall concepts also connect terrestrial demonstrations with planetary moon motion, comet trajectory, and more.

  4. Ozonation system for treatment of water in cooling towers

    Energy Technology Data Exchange (ETDEWEB)

    Coakley, T.G.; Horton, A.J. Jr.; Kaplan, B.E.

    1993-08-17

    An apparatus is described for controlling the condition of cooling tower system water, comprising one or more ozone generator electrodes having inner and outer concentric electrode tubes, a concentric dielectric tube there between creating an annular space between said dielectric tube and outer electrode tube for the passage of oxygen-containing air for conversion of a portion of said oxygen to ozone and first and second opposed end caps for supporting said electrode tubes and dielectric tube in a concentric orientation and for the entry of air into and exit of ozone-containing air from said annular space; means for providing dry, filtered input air at a depressed dewpoint and at constant flow rate to the first end caps of said electrodes; sensor means for determining the oxidation-reduction potential of a water sample obtained from the system; means coupled to said sensor means and to said ozone generator electrodes for maintaining the oxidation-reduction potential of said cooling tower system water at a target level in the range of about 550 to 6,750 mv by comparing the determined oxidation-reduction potential with said target value and controlling the production of ozone in response thereto to allow the generation and maintenance of containment oxidation by-product secondary biocides at an elevated level; means for combining the ozone produced by said electrodes with a portion of said cooling tower system water for return of resulting ozonated water to the system for introduction of the ozone thereto; and means for monitoring the flow of said input air and the output of said electrodes whereby an alarm condition is indicated if said flow or output depart from established parameters.

  5. Energy and exergy analysis of solar power tower plants

    International Nuclear Information System (INIS)

    Xu Chao; Wang Zhifeng; Li Xin; Sun Feihu

    2011-01-01

    Establishing the renewable electricity contribution from solar thermal power systems based on energy analysis alone cannot legitimately be complete unless the exergy concept becomes a part of that analysis. This paper presents a theoretical framework for the energy analysis and exergy analysis of the solar power tower system using molten salt as the heat transfer fluid. Both the energy losses and exergy losses in each component and in the overall system are evaluated to identify the causes and locations of the thermodynamic imperfection. Several design parameters including the direct normal irradiation (DNI), the concentration ratio, and the type of power cycle are also tested to evaluate their effects on the energy and exergy performance. The results show that the maximum exergy loss occurs in the receiver system, followed by the heliostat field system, although main energy loss occurs in the power cycle system. The energy and exergy efficiencies of the receiver and the overall system can be increased by increasing the DNI and the concentration ratio, but that increment in the efficiencies varies with the values of DNI and the concentration ratio. It is also found that the overall energy and exergy efficiencies of the solar tower system can be increased to some extent by integrating advanced power cycles including reheat Rankine cycles and supercritical Rankine cycles. - Highlights: →We presented a theoretical framework for the energy and exergy analysis of the solar tower system. →We tested the effects of several design parameters on the energy and exergy performance. →The maximum exergy loss occurs in the receiver system, followed by the heliostat field system. →Integrating advanced power cycles leads to increases in the overall energy and exergy efficiencies.

  6. Optical fiber stripper positioning apparatus

    Science.gov (United States)

    Fyfe, Richard W.; Sanchez, Jr., Amadeo

    1990-01-01

    An optical fiber positioning apparatus for an optical fiber stripping device is disclosed which is capable of providing precise axial alignment between an optical fiber to be stripped of its outer jacket and the cutting blades of a stripping device. The apparatus includes a first bore having a width approximately equal to the diameter of an unstripped optical fiber and a counter bore axially aligned with the first bore and dimensioned to precisely receive a portion of the stripping device in axial alignment with notched cutting blades within the stripping device to thereby axially align the notched cutting blades of the stripping device with the axis of the optical fiber to permit the notched cutting blades to sever the jacket on the optical fiber without damaging the cladding on the optical fiber. In a preferred embodiment, the apparatus further includes a fiber stop which permits determination of the length of jacket to be removed from the optical fiber.

  7. Cooling Tower (Evaporative Cooling System) Measurement and Verification Protocol

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Boyd, Brian [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stoughton, Kate M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lewis, Taylor [Colorado Energy Office, Denver, CO (United States)

    2017-12-05

    This measurement and verification (M and V) protocol provides procedures for energy service companies (ESCOs) and water efficiency service companies (WESCOs) to determine water savings resulting from water conservation measures (WCMs) in energy performance contracts associated with cooling tower efficiency projects. The water savings are determined by comparing the baseline water use to the water use after the WCM has been implemented. This protocol outlines the basic structure of the M and V plan, and details the procedures to use to determine water savings.

  8. Factors Stimulating Propagation of Legionellae in Cooling Tower Water

    OpenAIRE

    Yamamoto, Hiroyuki; Sugiura, Minoru; Kusunoki, Shinji; Ezaki, Takayuki; Ikedo, Masanari; Yabuuchi, Eiko

    1992-01-01

    Our survey of cooling tower water demonstrated that the highest density of legionellae, ≥104 CFU/100 ml, appeared in water containing protozoa, ≥102 MPN/100 ml, and heterotrophic bacteria, ≥106 CFU/100 ml, at water temperatures between 25 and 35°C. Viable counts of legionellae were detected even in the winter samples, and propagation, up to 105 CFU/100 ml, occurs in summer. The counts of legionellae correlated positively with increases in water temperature, pH, and protozoan counts, but not w...

  9. The depletion of aqueous nitrous acid in packed towers

    International Nuclear Information System (INIS)

    Counce, R.M.; Crawford, D.B.

    1987-01-01

    The depletion of aqueous nitrous acid was studied at 298 0 K and at slightly greater than atmospheric pressure. Solutions containing nitrous and nitric acids were contacted with nitrogen in towers packed with 6- and 13-mm Intalox saddles. The results indicate the existence of two depletion mechanisms for the conditions studied - liquid-phase decomposition and direct desorption of nitrous acid. Models based on mass-transfer and chemical-kinetic information are presented to explain the experimental results. 24 refs., 8 figs., 3 tabs

  10. TDRS-H is lifted up launch tower at CCAFS

    Science.gov (United States)

    2000-01-01

    An overhead crane is positioned on the nose fairing covering the Tracking and Data Relay Satellite (TDRS-H) in order to lift it up the tower at Launch Pad 36A, Cape Canaveral Air Force Station. It will be mated with the Atlas IIA/Centaur rocket, which is already stacked, for launch on June 29. The satellite will augment the TDRS system's existing S- and Ku-band frequencies by adding Ka- band capability. TDRS will serve as the sole means of continuous, high-data-rate communication with the Space Shuttle, with the International Space Station upon its completion, and with dozens of unmanned scientific satellites in low earth orbit.

  11. Industrial Process Cooling Towers: National Emission Standards for Hazardous Air Pollutants

    Science.gov (United States)

    Standards limiting discharge of chromium compound air emissions from industrial process cooling towers (IPCT's). Includes rule history, Federal Registry citations, implementation information and additional resources.

  12. Wind-induced response of CN-Tower: comparison of model and full scale

    International Nuclear Information System (INIS)

    Monbaliu, J.; Ruigrok, C.; Isyumov, N.

    1985-01-01

    The approximately 555-m high CN Communications Tower in Toronto has now been operational for nearly a decade. The action of wind on this tower was extensively tested at the Boundary Layer Wind Tunnel Laboratory during the design of the tower. This study provided information on the overall wind loads and responses of the structure, the action of wind on various components, and its effects on the tower performance including transmission quality. A program of monitoring and recording the wind induced response and various meteorological data was started in 1977. This paper presents some results of that program and makes comparisons with wind tunnel model data. (author)

  13. Comparative study on thermal performance of natural draft cooling towers with finned shells

    Energy Technology Data Exchange (ETDEWEB)

    Goodarzi, Mohsen [Bu-Ali Sina Univ., Hamedan (Iran, Islamic Republic of). Dept. of Mechanical Engineering

    2016-10-15

    The cooling efficiency of natural draft cooling towers under crosswind condition should be improved. In the present research work three different externally finned shells were considered for a typical natural draft cooling tower to investigate the cooling improvement. They were numerically simulated under normal and crosswind conditions. Numerical results show that twisting four fin plates over the tower shell along the 45 peripheral angle, could improve the cooling efficiency up to 6.5 %. Because of the periodic shape of the fin plates, the cooling efficiency of the cooling tower with finned shell is less sensitive to the change of wind.

  14. Hudson River cooling tower proceeding: Interface between science and law

    International Nuclear Information System (INIS)

    Bergen, G.S.P.

    1988-01-01

    As the Hudson River power plant case proceeded, the regulatory ground shifted under the utility companies. At first, the US Environmental Protection Agency (EPA) contended that the utilities should build expensive closed-cycle cooling towers at three plants to minimize the plants' discharge of heated effluents to the river. When the formal hearing began, however, EPA claimed that cooling towers were needed to minimize the number of organisms impinged at and entrained through the plants. The Hudson River proceeding became a policy dispute over what the appropriate standard of environmental conduct should be, instead of a determination of whether a standard had been met or not. Such policy issues, which arise when legal precedent has yet to be developed for new laws like the Clean Water Act, are better addressed by a rule-making proceeding than by the adjudicatory hearing format used in the Hudson case. A rule-making proceeding would have markedly shortened the Hudson deliberations, probably without substantive change in the final settlement, and is recommended for future cases in which ambiguity in legislation or the lack of precedent has left policy matters unresolved. 2 refs

  15. QUANTUS: Implementing atom optical experiments in the Bremen drop tower

    Science.gov (United States)

    Müntinga, Hauke; van Zoest, T.; Ahlers, H.; Seidel, S. T.; Herr, W.; Rudolph, J.; Gaaloul, N.; Singh, Y.; Schulze, T. A.; Rode, C.; Schkolnik, V.; Ertmer, W.; Rasel, E.; Müntinga, H.; Künemann, T.; Resch, A.; Herrmann, S.; Lümmerzahl, C.; Dittus, H.; Vogel, A.; Wenzlawski, A.; Sengstock, K.; Meyer, N.; Bongs, K.; Krutzik, M.; Lewoczko-Adamczyk, W.; Schiemangk, M.; Peters, A.; Eckart, M.; Kajari, E.; Arnold, S.; Nandi, G.; Walser, R.; Schleich, W. P.; Steinmetz, T.; Hünsch, T. W.; Reichel, J.

    We report on the current status of the QUANTUS free fall BEC experiment at the ZARM drop tower in Bremen. After the first realization of a BEC in microgravity in 2007, we were able to observe conden-sates after an unprecedented time of free evolution. The extremely shallow traps possible in microgravity and resulting ultralow temperatures of a few nK allow for further studies ranging from coherence properties of condensates to inertial sensors based on matter waves. In our talk we will focus on technological challanges of the project and its roll in bringing matter wave optics into space. A drop tower experiment is considered a stepping stone towards the ISS or other platforms as it makes high demands on mechanical stability, power consumption and payload. After showing the feasibility of such a project we are now working on a second generation apparatus which leads the way to high precision measurements of gravitational forces and eventually a quantum test of Einstein's weak equivalence principle. These goals are worked on in close cooperation with QUEST and the projects PRIMUS and LASUS. The QUANTUS project is a collaboration of U Hamburg, U Ulm, HU Berlin, MPQ Munich, ZARM at U Bremen and LU Hannover. It is supported by the German Space Agency DLR with funds provided by the Federal Ministry of Economics and Technology (BMWi) under grant numbers 50WM0835 -50WM0839.

  16. Coagulation chemistries for silica removal from cooling tower water.

    Energy Technology Data Exchange (ETDEWEB)

    Nyman, May Devan; Altman, Susan Jeanne; Stewart, Tom

    2010-02-01

    The formation of silica scale is a problem for thermoelectric power generating facilities, and this study investigated the potential for removal of silica by means of chemical coagulation from source water before it is subjected to mineral concentration in cooling towers. In Phase I, a screening of many typical as well as novel coagulants was carried out using concentrated cooling tower water, with and without flocculation aids, at concentrations typical for water purification with limited results. In Phase II, it was decided that treatment of source or make up water was more appropriate, and that higher dosing with coagulants delivered promising results. In fact, the less exotic coagulants proved to be more efficacious for reasons not yet fully determined. Some analysis was made of the molecular nature of the precipitated floc, which may aid in process improvements. In Phase III, more detailed study of process conditions for aluminum chloride coagulation was undertaken. Lime-soda water softening and the precipitation of magnesium hydroxide were shown to be too limited in terms of effectiveness, speed, and energy consumption to be considered further for the present application. In Phase IV, sodium aluminate emerged as an effective coagulant for silica, and the most attractive of those tested to date because of its availability, ease of use, and low requirement for additional chemicals. Some process optimization was performed for coagulant concentration and operational pH. It is concluded that silica coagulation with simple aluminum-based agents is effective, simple, and compatible with other industrial processes.

  17. Modified corrosion protection coatings for Concrete tower of Transmission line

    Science.gov (United States)

    Guo, Kai; Jing, Xiangyang; Wang, Hongli; Yue, Zengwu; Wu, Yaping; Mi, Xuchun; Li, Xingeng; Chen, Suhong; Fan, Zhibin

    2017-12-01

    By adding nano SiO2 particles, an enhanced K-PRTV anti-pollution flashover coating had been prepared. Optical profile meter (GT-K), atomic force microscopy (AFM) and infrared spectrometer (FT-IR) characterization were carried out on the coating surface analysis. With the use of modified epoxy resin as the base material, the supplemented by phosphate as a corrosion stabilizer, to achieve a corrosion of steel and galvanized steel with rust coating. Paint with excellent adhesion, more than 10MPa (1), resistant to neutral salt spray 1000h does not appear rust point. At the same time coating a large amount of ultra-fine zinc powder can be added for the tower galvanized layer zinc repair function, while the paint in the zinc powder for the tower to provide sacrificial anode protection, to achieve self-repair function of the coating. Compared to the market with a significant reduction in the cost of rust paint, enhance the anti-corrosion properties.

  18. Impact of tower modeling on wind turbine wakes

    Science.gov (United States)

    Kleusberg, Elektra; Schlatter, Philipp; Henningson, Dan

    2017-11-01

    Recent research suggests the importance of modeling the support structure (tower and nacelle) when investigating the wake development behind wind turbines. These investigations are however mostly limited to low ambient turbulence levels which seldomly occur in field conditions. We present numerical simulations of wind turbine wakes using the actuator line method under different inflow conditions including varying turbulence levels and sheared inflow. The wind turbine, which employs the NREL S826 airfoil, is modeled after experiments conducted at the Norwegian University of Science and Technology. The rotor is investigated when perpendicular to the inflow and at a yaw angle of 30 degrees. The support structure is modeled using lift and drag body forces based on tabulated data. The simulations are performed with the spectral-element code Nek5000. After discussing the setup of the numerical domain and the turbulent inflow boundary condition, the influence of the tower model is characterized under turbulent, sheared and uniform inflow and the impact on downstream turbines is evaluated.

  19. Radiation Testing of PICA at the Solar Power Tower

    Science.gov (United States)

    White, Susan

    2010-01-01

    Sandia National Laboratory's Solar Power Tower was used to irradiate specimens of Phenolic Impregnated Carbon Ablator (PICA), in order to evaluate whether this thermal protection system material responded differently to potential shock layer radiative heating than to convective heating. Tests were run at 50, 100 and 150 Watts per square centimeter levels of concentrated solar radiation. Experimental results are presented both from spectral measurements on 1- 10 mm thick specimens of PICA, as well as from in-depth temperature measurements on instrumented thicker test specimens. Both spectral measurements and measured in-depth temperature profiles showed that, although it is a porous, low-density material, PICA does not exhibit problematic transparency to the tested high levels of NIR radiation, for all pragmatic cm-to-inch scale thicknesses. PICA acted as a surface absorber to efficiently absorb the incident visible and near infrared incident radiation in the top 2 millimeter layer in the Solar Power Tower tests up to 150 Watts per square centimeter.

  20. Stabilization of bottom sediments from Rzeszowski Reservoir

    Directory of Open Access Journals (Sweden)

    Koś Karolina

    2015-06-01

    Full Text Available The paper presents results of stabilization of bottom sediments from Rzeszowski Reservoir. Based on the geotechnical characteristics of the tested sediments it was stated they do not fulfill all the criteria set for soils in earth embankments. Therefore, an attempt to improve their parameters was made by using two additives – cement and lime. An unconfined compressive strength, shear strength, bearing ratio and pH reaction were determined on samples after different time of curing. Based on the carried out tests it was stated that the obtained values of unconfined compressive strength of sediments stabilized with cement were relatively low and they did not fulfill the requirements set by the Polish standard, which concerns materials in road engineering. In case of lime stabilization it was stated that the tested sediments with 6% addition of the additive can be used for the bottom layers of the improved road base.

  1. Reconciling Top-Down and Bottom-Up Estimates of Oil and Gas Methane Emissions in the Barnett Shale

    Science.gov (United States)

    Hamburg, S.

    2015-12-01

    Top-down approaches that use aircraft, tower, or satellite-based measurements of well-mixed air to quantify regional methane emissions have typically estimated higher emissions from the natural gas supply chain when compared to bottom-up inventories. A coordinated research campaign in October 2013 used simultaneous top-down and bottom-up approaches to quantify total and fossil methane emissions in the Barnett Shale region of Texas. Research teams have published individual results including aircraft mass-balance estimates of regional emissions and a bottom-up, 25-county region spatially-resolved inventory. This work synthesizes data from the campaign to directly compare top-down and bottom-up estimates. A new analytical approach uses statistical estimators to integrate facility emission rate distributions from unbiased and targeted high emission site datasets, which more rigorously incorporates the fat-tail of skewed distributions to estimate regional emissions of well pads, compressor stations, and processing plants. The updated spatially-resolved inventory was used to estimate total and fossil methane emissions from spatial domains that match seven individual aircraft mass balance flights. Source apportionment of top-down emissions between fossil and biogenic methane was corroborated with two independent analyses of methane and ethane ratios. Reconciling top-down and bottom-up estimates of fossil methane emissions leads to more accurate assessment of natural gas supply chain emission rates and the relative contribution of high emission sites. These results increase our confidence in our understanding of the climate impacts of natural gas relative to more carbon-intensive fossil fuels and the potential effectiveness of mitigation strategies.

  2. High resolution bottom penetrating sonar. Test report

    Energy Technology Data Exchange (ETDEWEB)

    Volberg, H.

    1996-08-01

    The Great Belt Sonar (GBS) is a multi-functional sub-bottom profiling and buried object detection sonar system that can provide a wide variety of selectable operations based on user needs and environmental characteristics. In order to assess the bottom penetration and pipe tracking performance of the sonar system, controlled laboratory tests with known environmental parameters are required. Once the general characteristic and the potential for pipe detection of the system under the laboratory environment are established, field tests can be carried out to fully exercise all the system operations under the real ocean environment. Theoretical small scale system test considerations and a system setup for proof-of-concept trials have been proposed in `Pipe Tracking Sonar`, technical report. This report describes recent testing of the GBS system under small scale controlled laboratory environment. The experiment objectives given the size limitations of the laboratory environment, and the test equipment configuration and setup are described. The GBS system test measurements and findings are given. Finally, conclusions and future design and test considerations are discussed. The report assumes familiarity with the GBS system specifications and operational characteristics as well as theoretical background on acoustic propagation through the water-bottom interface. (EG)

  3. Cellular Phone Towers, Cell tower locations as derived from various sources including the Department of Licenses and Inspections and the Department of Planning and Zoning., Published in 2010, 1:2400 (1in=200ft) scale, Howard County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Cellular Phone Towers dataset current as of 2010. Cell tower locations as derived from various sources including the Department of Licenses and Inspections and the...

  4. From the Eiffel Tower to the Javanese Dancer: Envisioning Cultural Globalization at the 1889 Paris Exhibition

    Science.gov (United States)

    Young, Patrick

    2008-01-01

    Arguably the two main attractions for visitors to the 1889 "Exposition Universelle" (Universal Exposition), the Eiffel Tower and the live dancers from the Dutch colony of Java make for a provocative juxtaposition. Constructed expressly for the 1889 Exhibition, Gustave Eiffel's 106-story iron lattice tower became not only the world's…

  5. Performance Evaluation on Transmission Tower-Line System with Passive Friction Dampers Subjected to Wind Excitations

    Directory of Open Access Journals (Sweden)

    Bo Chen

    2015-01-01

    Full Text Available The vibration control and performance evaluation on a transmission-tower line system by using friction dampers subjected to wind excitations are carried out in this study. The three-dimensional finite element (FE model of a transmission tower is firstly constructed. A two-dimensional lumped mass model of a transmission tower is developed for dynamic analysis. The analytical model of transmission tower-line system is proposed by taking the dynamic interaction between the tower and the transmission lines into consideration. The mechanical model of passive friction damper is presented by involving the effects of damper axial stiffness. The equation of motion of the transmission tower-line system incorporated with the friction dampers disturbed by wind excitations is established. A real transmission tower-line system is taken as an example to examine the feasibility and reliability of the proposed control approach. An extensive parameter study is carried out to find the optimal parameters of friction damper and to assess the effects of slipping force axial stiffness and hysteresis loop on control performance. The work on an example structure indicates that the application of friction dampers with optimal parameters could significantly reduce wind-induced responses of the transmission tower-line system.

  6. Heat Transfer Enhancement of the Air-Cooling Tower with Rotating Wind Deflectors under Crosswind Conditions

    Directory of Open Access Journals (Sweden)

    Xueping Du

    2018-04-01

    Full Text Available To investigate the effect of wind deflectors on air flow and heat transfer performance of an air-cooling tower under crosswind conditions, an experimental system based on a surface condenser aluminum exchanger-type indirect air-cooling tower is established at a 1:100 proportional reduction. A 3-D computational fluid dynamics simulation model is built to study the air flow and temperature fields. The air flow rate into the cooling tower and the heat transfer rate of the radiators are used to evaluate cooling performance. Rotating wind deflectors are adopted to reduce the influence of crosswind on the cooling tower performance. The effects of the rotating wind deflectors on the thermal-hydraulic characteristics of the air-cooling tower under different environmental crosswind speeds are studied. Results indicate that the wind direction in the tower reverses as the rotating speed of the wind deflectors increases. The thermal performance of an air-cooling tower under crosswind conditions can be improved by using rotating wind deflectors. The heat transfer rate of a cooling tower with eight wind deflectors begins to increase when the rotating speed exceeds 2 r/min.

  7. Fire analog: a comparison between fire plumes and energy center cooling tower plumes

    Energy Technology Data Exchange (ETDEWEB)

    Orgill, M.M.

    1977-10-01

    Thermal plumes or convection columns associated with large fires are compared to thermal plumes from cooling towers and proposed energy centers to evaluate the fire analog concept. Energy release rates of mass fires are generally larger than for single or small groups of cooling towers but are comparable to proposed large energy centers. However, significant physical differences exist between cooling tower plumes and fire plumes. Cooling tower plumes are generally dominated by ambient wind, stability and turbulence conditions. Fire plumes, depending on burning rates and other factors, can transform into convective columns which may cause the fire behavior to become more violent. This transformation can cause strong inflow winds and updrafts, turbulence and concentrated vortices. Intense convective columns may interact with ambient winds to create significant downwind effects such as wakes and Karman vortex streets. These characteristics have not been observed with cooling tower plumes to date. The differences in physical characteristics between cooling tower and fire plumes makes the fire analog concept very questionable even though the approximate energy requirements appear to be satisfied in case of large energy centers. Additional research is suggested in studying the upper-level plume characteristics of small experimental fires so this information can be correlated with similar data from cooling towers. Numerical simulation of fires and proposed multiple cooling tower systems could also provide comparative data.

  8. Influence of execution tolerances for friction connections in circular and polygonal towers for wind converters

    NARCIS (Netherlands)

    Heistermann, Christine; Pavlovic, M.; Veljkovic, M.; Pak, Daniel; Feldmann, Markus; Rebelo, Carlos; da Silva, Luís Simões

    2017-01-01

    Friction connections with long open slotted holes have been proven to be a competitive alternative to the conventional flange connections in steel tubular towers for wind energy converters. As full-scale tests are not available, results of Finite Element Analysis (FEA) of the real-scale tower

  9. Isolation of Legionella pneumophila from hospital cooling towers in Johor, Malaysia.

    Science.gov (United States)

    Abdul Samad, B H; Suhaili, M R; Baba, N; Rajasekaran, G

    2004-08-01

    Water-based cooling towers and their water supply at two hospitals in Johor were surveyed for the presence Legionella pneumophila. L. pneumophila were grown from 19 (76%) out of 25 collected water samples. One hospital cooling tower was contaminated with L. pneumophila serogroup 1.

  10. BOREAS TF-3 NSA-OBS Tower Flux, Meteorological, and Soil Temperature Data

    Science.gov (United States)

    Wofsy, Steven; Sutton, Doug; Goulden, Mike; Hall, Forrest G. (Editor); Huemmrich, Karl (Editor)

    2000-01-01

    The BOReal Ecosystem-Atmosphere Study Tower Flux (BOREAS TF-3) team collected tower flux, surface meteorological, and soil temperature data at the BOREAS Northern Study Area-Old Black Spruce (NSA-OBS) site continuously from the March 1994 through October 1996. The data are available in tabular ASCII files.

  11. Using the Tower of Hanoi Puzzle to Infuse Your Mathematics Classroom with Computer Science Concepts

    Science.gov (United States)

    Marzocchi, Alison S.

    2016-01-01

    This article suggests that logic puzzles, such as the well-known Tower of Hanoi puzzle, can be used to introduce computer science concepts to mathematics students of all ages. Mathematics teachers introduce their students to computer science concepts that are enacted spontaneously and subconsciously throughout the solution to the Tower of Hanoi…

  12. Upper estimates of complexity of algorithms for multi-peg Tower of Hanoi problem

    Directory of Open Access Journals (Sweden)

    Sergey Novikov

    2007-06-01

    Full Text Available There are proved upper explicit estimates of complexity of lgorithms: for multi-peg Tower of Hanoi problem with the limited number of disks, for Reve's puzzle and for $5$-peg Tower of Hanoi problem with the free number of disks.

  13. Tower of Hanoi disk-transfer task: Influences of strategy knowledge and learning on performance

    NARCIS (Netherlands)

    Welsh, M.C.; Huizinga, M.

    2005-01-01

    Tower of Hanoi has become a popular tool in cognitive and neuropsychology to assess a set of behaviors collectively referred to as executive functions. Substantial variability in performance on the Tower of Hanoi (TOH) disk-transfer task among normally functioning young adults, and potential

  14. The caracol tower at chichen itza: an ancient astronomical observatory?

    Science.gov (United States)

    Aveni, A F; Gibbs, S L; Hartung, H

    1975-06-06

    platforms of the Caracol seem to have been laid out deliberately to point to horizon events involving the sun and the planet Venus. Of the lines taken through the windows, the Venus setting points seem most plausible to us in view of both the accuracy with which they fit the architecture and the historical evidence bearing upon the importance of Venus to the Mesoamerican people. A specific connection between the Venus calendar in the Dresden Codex and the sighting of the extreme positions of the planet along the horizon, however, is yet to be established. It is especially significant that alignments in both the base and the top of the tower relate to Venus. The solar equinox alignment in window I remains problematical, although the arrangement probably functioned as an approximate means of determining the first day of spring and the first day of autumn. Lines pointing to individual bright stars undoubtedly should be given lower value. If one is willing to carry the matching game to its ultimate completion, a stellar object can always be found which, although very obscure, will fit an alignment. In our consideration of the problem we have attempted to single out bright stars which appeared or disappeared on significant calendar dates. Other round structures resembling the Caracol exist in Mesoamerica (20), although there are comparatively few built by the Maya. Nearly all can be attributed to the cult of Quetzalcoatl (34). To our knowledge none have been carefully measured and analyzed for astronomical orientations. The ruined tower Q-152 at Mayapan bore distinct similarities to the Caracol, both in shape and structure. It probably contained only a single doorway which faced west. Both structures possessed circular corridors. A circular tower is still standing at Paalmul on the coast of Quintana Roo north of Tulum. Pollock (20, p. 115) states that it has a single room in the turret. A window similar to No. I in the Caracol faces northwest, the same direction as the base of

  15. Bottom Trawl Survey Protocol Development (HB0706, EK60)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Cruise objectives include: 1) Investigate performance characteristics of new research bottom trawl; 2) Develop standard operating procedures for the NEFSC Bottom...

  16. Microgravity Experiment Programs for Students at the Bremen Drop Tower

    Science.gov (United States)

    Könemann, Thorben; Eigenbrod, Christian; Von Kampen, Peter; Laemmerzahl, Claus

    The Center of Applied Space Technology and Microgravity (ZARM) founded by Prof. Dr.-Ing. Hans J. Rath in 1985 is part of the Department of Production Engineering at the University of Bremen, Germany. ZARM established as a research center and currently headed by Prof. Dr. Claus Lämmerzahl is mainly concentrated on fundamental investigations of gravitational and space-related phenomenas under conditions of weightlessness as well as questions and developments related to technologies for space. At ZARM more than 70 scientists, engineers and administrative staff as well as many students from different departments are employed. Today, ZARM is still one of the largest and most important university institutes for space sciences and technologies in Europe as well as worldwide well known in the space community. With a height of 146 m the Bremen Drop Tower is the predominant facility of ZARM and also the only drop tower of its class in Europe. ZARM’s ground-based laboratory offers the opportunity for daily short-term experiments under conditions of high-quality weightlessness at a level of 10 (-6) g (microgravity). The provided quality is one of the purest for experiments under weightlessness worldwide achieved. The scientists may choose between a single drop experiment with 4.74 s in simple free fall and a catapult experiment with 9.3 s of weightlessness. Either in the drop or in the worldwide unique catapult operation routine the repetition rates of microgravity experiments at ZARM are always the same, generally up to 3 times per day. Since the start of operation of the facility in 1990, over 6750 launches of more than 160 different experiment types from various scientific fields like Fundamental Physics, Combustion, Fluid Dynamics, Planetary Formation / Astrophysics, Biology and Materials Sciences have been successfully accomplished so far. In our paper we will report and inform about microgravity experiment programs for students like "Drop Your Thesis!“ by ESA and

  17. Control of Carbon Nanotube Density and Tower Height in an Array

    Science.gov (United States)

    Delzeit, Lance D. (Inventor); Schipper, John F. (Inventor)

    2010-01-01

    A method for controlling density or tower height of carbon nanotube (CNT) arrays grown in spaced apart first and second regions on a substrate. CNTs having a first density range (or first tower height range) are grown in the first region using a first source temperature range for growth. Subsequently or simultaneously, CNTs having a second density range (or second tower height range), having an average density (or average tower height) in the second region different from the average density (or average tower height) for the first region, are grown in the second region, using supplemental localized hearing for the second region. Application for thermal dissipation and/or dissipation of electrical charge or voltage in an electronic device are discussed.

  18. Data from an instrumented navigational light tower off the Savanah River estuary

    International Nuclear Information System (INIS)

    Hayes, D.W.; Dicks, A.S.; Blanton, J.O.

    1978-01-01

    An oceanographic and meteorological instrumentation system operating on the Savannah Navigational Light Tower is providing synoptic information on ocean temperatures, currents, tides, and meteorological conditions. The Savannah Navigational Light Tower, an unmanned U.S. Coast Guard tower, is located about nine miles off Savannah Beach, Georgia, in about 16 m of water. The tower is currently instrumented to measure and record water temperatures from six depths, water velocities at two depts, tides, air temperature, barometric pressure, and wind speed and velocity at two heights. The outputs are currently being recorded every 10 minutes. These data aid in the interpretation of the processes governing pollutant transport in the Savannah River marine region and support other DOE funded programs in the southeastern United States. This past year, computer programs were written and are being tested for processing the raw data from the tower and for performing correlative analysis of the data

  19. System and method for aligning heliostats of a solar power tower

    Science.gov (United States)

    Convery, Mark R.

    2013-01-01

    Disclosed is a solar power tower heliostat alignment system and method that includes a solar power tower with a focal area, a plurality of heliostats that each reflect sunlight towards the focal area of the solar power tower, an off-focal area location substantially close to the focal area of the solar power tower, a communication link between the off-focal area location and a misaligned heliostat, and a processor that interprets the communication between the off-focal area location and the misaligned heliostat to identify the misaligned heliostat from the plurality of heliostats and that determines a correction for the identified misaligned heliostat to realign the misaligned heliostat to reflect sunlight towards the focal area of the solar power tower.

  20. Evaluating the Effectiveness of Wildlife Detection and Observation Technologies at a Solar Power Tower Facility.

    Directory of Open Access Journals (Sweden)

    Robert H Diehl

    Full Text Available Solar power towers produce electrical energy from sunlight at an industrial scale. Little is known about the effects of this technology on flying animals and few methods exist for automatically detecting or observing wildlife at solar towers and other tall anthropogenic structures. Smoking objects are sometimes observed co-occurring with reflected, concentrated light ("solar flux" in the airspace around solar towers, but the identity and origins of such objects can be difficult to determine. In this observational pilot study at the world's largest solar tower facility, we assessed the efficacy of using radar, surveillance video, and insect trapping to detect and observe animals flying near the towers. During site visits in May and September 2014, we monitored the airspace surrounding towers and observed insects, birds, and bats under a variety of environmental and operational conditions. We detected and broadly differentiated animals or objects moving through the airspace generally using radar and near solar towers using several video imaging methods. Video revealed what appeared to be mostly small insects burning in the solar flux. Also, we occasionally detected birds flying in the solar flux but could not accurately identify birds to species or the types of insects and small objects composing the vast majority of smoking targets. Insect trapping on the ground was somewhat effective at sampling smaller insects around the tower, and presence and abundance of insects in the traps generally trended with radar and video observations. Traps did not tend to sample the larger insects we sometimes observed flying in the solar flux or found dead on the ground beneath the towers. Some of the methods we tested (e.g., video surveillance could be further assessed and potentially used to automatically detect and observe flying animals in the vicinity of solar towers to advance understanding about their effects on wildlife.

  1. Evaluating the effectiveness of wildlife detection and observation technologies at a solar power tower facility

    Science.gov (United States)

    Diehl, Robert H.; Valdez, Ernest W.; Preston, Todd M.; Wellik, Mike J.; Cryan, Paul

    2016-01-01

    Solar power towers produce electrical energy from sunlight at an industrial scale. Little is known about the effects of this technology on flying animals and few methods exist for automatically detecting or observing wildlife at solar towers and other tall anthropogenic structures. Smoking objects are sometimes observed co-occurring with reflected, concentrated light (“solar flux”) in the airspace around solar towers, but the identity and origins of such objects can be difficult to determine. In this observational pilot study at the world’s largest solar tower facility, we assessed the efficacy of using radar, surveillance video, and insect trapping to detect and observe animals flying near the towers. During site visits in May and September 2014, we monitored the airspace surrounding towers and observed insects, birds, and bats under a variety of environmental and operational conditions. We detected and broadly differentiated animals or objects moving through the airspace generally using radar and near solar towers using several video imaging methods. Video revealed what appeared to be mostly small insects burning in the solar flux. Also, we occasionally detected birds flying in the solar flux but could not accurately identify birds to species or the types of insects and small objects composing the vast majority of smoking targets. Insect trapping on the ground was somewhat effective at sampling smaller insects around the tower, and presence and abundance of insects in the traps generally trended with radar and video observations. Traps did not tend to sample the larger insects we sometimes observed flying in the solar flux or found dead on the ground beneath the towers. Some of the methods we tested (e.g., video surveillance) could be further assessed and potentially used to automatically detect and observe flying animals in the vicinity of solar towers to advance understanding about their effects on wildlife.

  2. Evaluating the Effectiveness of Wildlife Detection and Observation Technologies at a Solar Power Tower Facility.

    Science.gov (United States)

    Diehl, Robert H; Valdez, Ernest W; Preston, Todd M; Wellik, Michael J; Cryan, Paul M

    2016-01-01

    Solar power towers produce electrical energy from sunlight at an industrial scale. Little is known about the effects of this technology on flying animals and few methods exist for automatically detecting or observing wildlife at solar towers and other tall anthropogenic structures. Smoking objects are sometimes observed co-occurring with reflected, concentrated light ("solar flux") in the airspace around solar towers, but the identity and origins of such objects can be difficult to determine. In this observational pilot study at the world's largest solar tower facility, we assessed the efficacy of using radar, surveillance video, and insect trapping to detect and observe animals flying near the towers. During site visits in May and September 2014, we monitored the airspace surrounding towers and observed insects, birds, and bats under a variety of environmental and operational conditions. We detected and broadly differentiated animals or objects moving through the airspace generally using radar and near solar towers using several video imaging methods. Video revealed what appeared to be mostly small insects burning in the solar flux. Also, we occasionally detected birds flying in the solar flux but could not accurately identify birds to species or the types of insects and small objects composing the vast majority of smoking targets. Insect trapping on the ground was somewhat effective at sampling smaller insects around the tower, and presence and abundance of insects in the traps generally trended with radar and video observations. Traps did not tend to sample the larger insects we sometimes observed flying in the solar flux or found dead on the ground beneath the towers. Some of the methods we tested (e.g., video surveillance) could be further assessed and potentially used to automatically detect and observe flying animals in the vicinity of solar towers to advance understanding about their effects on wildlife.

  3. Bottom-up grammar analysis : a functional formulation

    NARCIS (Netherlands)

    Jeuring, J.T.; Swierstra, D.

    1994-01-01

    This paper discusses bottom-up grammar analysis problems such as te EMPTY problem and the FIRST problem. It defines a general class of bottom-up grammar analysis problems, and from this definition it derives a functional program for performing bottom-up grammar analysis. The derivation is purely

  4. 49 CFR 179.100-14 - Bottom outlets.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Bottom outlets. 179.100-14 Section 179.100-14... Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.100-14 Bottom outlets. (a) Bottom outlets for discharge of lading is prohibited, except as provided in § 179.103-3. If...

  5. 49 CFR 179.103-5 - Bottom outlets.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Bottom outlets. 179.103-5 Section 179.103-5... Specifications for Pressure Tank Car Tanks (Classes DOT-105, 109, 112, 114 and 120) § 179.103-5 Bottom outlets... devices as prescribed in § 179.103-3, tanks may be equipped with approved bottom outlet valves. If applied...

  6. Device for noise-abatement in a cooling tower

    International Nuclear Information System (INIS)

    Baer, E.; Dittrich, H.; Ernst, G.; Roller, W.; Wurz, D.

    1977-01-01

    This device attenuates the noise of cooling water droplets falling out of trickling plates below a spray facility. In this manner expensive noise-attenuating cranks or embankments around the cooling tower become unnecessary. Noise attenuation is achieved by a catching device closely above the water reservoir. Instead of falling vertically on the water surface, the droplets hit the inclined surfaces of a horizontal grid. A number of such plane or slightly curved surfaces are placed together with little inclination against the vertical (25 0 to 30 0 , with a maximum of 45 0 ) at such a distance that no drop can hit the water surface directly, i.e. unattenuated. In a second type of design also the capacity of the cooling water pumps and with it the investment and operating cost is reduced. For instance, about 2000 kW are saved by higher arrangement of the catching device, closely below the trickling components. (RW) [de

  7. The Frari bell tower in Venice: study and restoration

    Directory of Open Access Journals (Sweden)

    Ilaria Cavaggioni

    2010-12-01

    Full Text Available The preliminary study, project and restoration process of the bell tower of the Frari church in Venice is an exemplary case of intervention on a historic building. This intervention started within depth research into the documentary data along with a detailed study of the material fabric which has made it possible to compare the verisimilitude and gaps in the historic sources, the evolution of the building, its built reality and the effects of the repair works carried out in the past at the same time as the damages in the fabric were monitored. Thanks to the knowledge thus gleaned, the restoration works proceeded with great caution in order to respect the material history of the building and short and long-term structural compatibility.

  8. Loss of coolant analysis for the tower shielding reactor 2

    International Nuclear Information System (INIS)

    Radcliff, T.D.; Williams, P.T.

    1990-06-01

    The operational limits of the Tower Shielding Reactor-2 (TSR-2) have been revised to account for placing the reactor in a beam shield, which reduces convection cooling during a loss-of-coolant accident (LOCA). A detailed heat transfer analysis was performed to set operating time limits which preclude fuel damage during a LOCA. Since a LOCA is survivable, the pressure boundary need not be safety related, minimizing seismic and inspection requirements. Measurements of reactor component emittance for this analysis revealed that aluminum oxidized in water may have emittance much higher than accepted values, allowing higher operating limits than were originally expected. These limits could be increased further with analytical or hardware improvements. 5 refs., 7 figs

  9. GREEN TOWERS AND ICONIC DESIGN: Cases from Three Continents

    Directory of Open Access Journals (Sweden)

    Kheir M Al-Kodmany

    2014-03-01

    Full Text Available Recently, massive urbanization, increasingly denser cities and environmental consciousness are pushing architects to build “green” skyscraper. This paper examines the emergence of a notable type of skyscrapers which depart from purely image-driven structures, and emphasizes functionality and energy efficiency. It argues that breathtaking green design and practical clean technology are merged to give birth to green architectural aesthetics. Upon reviewing over 30 towers from various parts of the world, the paper identifies salient green design strategies that provide new iconicity including: structural efficiencies, renewable energy, façade technology, greeneries, and bioclimatic design. Findings suggest that a dynamic synergy among innovative green design strategies, new architectural languages and exciting aesthetics has constituted a trend that is more likely to prevail in the 21st Century.

  10. Measurement of solar extinction in tower plants with digital cameras

    Science.gov (United States)

    Ballestrín, J.; Monterreal, R.; Carra, M. E.; Fernandez-Reche, J.; Barbero, J.; Marzo, A.

    2016-05-01

    Atmospheric extinction of solar radiation between the heliostat field and the receiver is accepted as a non-negligible source of energy loss in the increasingly large central receiver plants. However, the reality is that there is currently no reliable measurement method for this quantity and at present these plants are designed, built and operated without knowing this local parameter. Nowadays digital cameras are used in many scientific applications for their ability to convert available light into digital images. Its broad spectral range, high resolution and high signal to noise ratio, make them an interesting device in solar technology. In this work a method for atmospheric extinction measurement based on digital images is presented. The possibility of defining a measurement setup in circumstances similar to those of a tower plant increases the credibility of the method. This procedure is currently being implemented at Plataforma Solar de Almería.

  11. WJBF TV tower meteorological database for the ERAD Code-1993

    International Nuclear Information System (INIS)

    Weber, A.H.

    1996-07-01

    The Explosive Release Atmospheric Dispersion (ERAD) model (Boughton and DeLaurentis 1992) is a three-dimensional numerical model for simulating atmospheric transport and dispersion. The ERAD code is particularly adept at handling explosive releases into the atmosphere and is being used by the Materials and Accountability Department at the Savannah River Site (SRS) to provide risk estimates. The Environmental Technology Section (ETS) was asked to provide meteorological data to be used for applying ERAD to some site facilities. The ERAD model requires a vertical profile of meteorological measurements. The 1993 data from the WJBF-TV tower has been processed and provided for this purpose. This document describes the steps taken to prepare and format the database

  12. Hybrid cooling tower Neckarwestheim 2 cooling function, emission, plume dispersion

    International Nuclear Information System (INIS)

    Braeuning, G.; Ernst, G.; Maeule, R.; Necker, P.

    1990-01-01

    The fan-assisted hybrid cooling tower of the 1300 MW power plant Gemeinschafts-Kernkraftwerk Neckarwestheim 2 was designed and constructed based on results from theoretical and experimental studies and experiences from a smaller prototype. The wet part acts in counterflow. The dry part is arranged above the wet part. Each part contains 44 fans. Special attention was payed to the ducts which mix the dry into the wet plume. The cooling function and state, mass flow and contents of the emission were measured. The dispersion of the plume in the atmosphere was observed. The central results are presented in this paper. The cooling function corresponds to the predictions. The content of drifted cooling water in the plume is extremely low. The high velocity of the plume in the exit causes an undisturbed flow into the atmosphere. The hybrid operation reduces visible plumes strongly, especially in warmer and drier ambient air

  13. Operational cooling tower model (CTTOOL V1.0)

    Energy Technology Data Exchange (ETDEWEB)

    Aleman, S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); LocalDomainServers, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Garrett, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-01-01

    Mechanical draft cooling towers (MDCT’s) are widely used to remove waste heat from industrial processes, including suspected proliferators of weapons of mass destruction (WMD). The temperature of the air being exhausted from the MDCT is proportional to the amount of thermal energy being removed from the process cooling water, although ambient weather conditions and cooling water flow rate must be known or estimated to calculate the rate of thermal energy dissipation (Q). It is theoretically possible to derive MDCT air exhaust temperatures from thermal images taken from a remote sensor. A numerical model of a MDCT is required to translate the air exhaust temperature to a Q. This report describes the MDCT model developed by the Problem Centered Integrated Analysis (PCIA) program that was designed to perform those computational tasks. The PCIA program is a collaborative effort between the Savannah River National Laboratory (SRNL), the Northrop-Grumman Corporation (NG) and the Aerospace Corporation (AERO).

  14. Fatigue Reliability Analysis of a Mono-Tower Platform

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Sørensen, John Dalsgaard; Brincker, Rune

    1991-01-01

    In this paper, a fatigue reliability analysis of a Mono-tower platform is presented. The failure mode, fatigue failure in the butt welds, is investigated with two different models. The one with the fatigue strength expressed through SN relations, the other with the fatigue strength expressed...... through linear-elastic fracture mechanics (LEFM). In determining the cumulative fatigue damage, Palmgren-Miner's rule is applied. Element reliability, as well as systems reliability, is estimated using first-order reliability methods (FORM). The sensitivity of the systems reliability to various parameters...... is investigated. The systems reliability index, estimated by using the fatigue elements with the fatigue strength expressed through SN relations, is found to be smaller than the systems reliability index estimated by using LEFM. It is shown that the systems reliability index is very sensitive to variations...

  15. The investigation of cooling tower packing in various arrangements

    International Nuclear Information System (INIS)

    Golshayshi, H.R.; Missenden, J.F.

    1998-01-01

    The effect of form with corrugated packing on heat transfer and pressure drop characteristics in atmospheric cooling towers has been studied experimentally. The results showed that the heat transfer coefficient decreased with increase in packing pitch and increase in the ratio of rib pitch to rib height. Friction factors were expressed by a dimensional equation which included pitch and distance between the packings, for both smooth and rough surface. From these results, the relationship between packing heat transfer coefficient and pressure drop was deduced. The correlations were verified with additional experimental data taken with 1.1,P/D p /e 5 . This provides a useful semi experimental relation, in the area generally lacking in design and performance data. (author)

  16. AN APPLICATION FOR ELECTRICAL PRODUCTION WITH SOLAR TOWER SYSTEM

    Directory of Open Access Journals (Sweden)

    Reşat SELBAŞ

    2003-02-01

    Full Text Available The requirement of electric energy rises with increasing of the population and faster improvement demands. Energy necessity generally is provided by using fossil based fuel sources. In order to supply energy requirements, today, using alternative sources became necessary because of the problems such as decreasing of available fossil fuel sources and environment pollution from this fuel. The solar energy which has a wide range of application potential is the most hopeful and unlimited energy source without environment pollution in electric energy production. In this paper, the electric production methods from solar energy are studied and the most suitable method for solar energy plant is tried to find out. The selected method, known as Solar Tower in literature is an electric production method. In this study, technical and cost analysis of an application using this method are carried out.

  17. Saving assessment using the PERS in solar power towers

    International Nuclear Information System (INIS)

    Rodriguez-Sanchez, M.R.; Sanchez-Gonzalez, A.; Marugan-Cruz, C.; Santana, D.

    2014-01-01

    Highlights: • The lamination of the solar salt is avoided using the PERS and the main energy sink. • The PERS using salt pump as turbine saves 30–50% of the parasitic power. • The most appropriate configuration is a similar turbine three times one salt pump. • The payback period is around two years, and the economical savings from 1 to 4 M$. - Abstract: The improvement of the solar power tower using solar salt is one of the main goals of researchers. Any method or invention to improve the efficiency of this technology contributes to promote the renewable energies. The use of a Potential Energy Recovery System (PERS) in two different solar power tower plants of 20 and 100 MW has been analysed. The PERS is formed, at least, by one turbine, located at the hot salt pipe coming from the receiver. The turbine is engaged to the shaft of the feed pump, which raises the heat transfer fluid from the cold tank to the receiver. It reduces the parasitic power consumption of the plant, and increases its global efficiency. Different PERS configurations have been modelled. Based on an energetic and economic analysis, the optimal configuration is a geometrical similar turbine of three times the volume flow rate of one feed pump. The PERS has been proven to be a cost reductive and clean tool. For a 100 MW power plant of 30-year lifetime the investment cost is 1.26 M$ and the annual cash flow is 0.89 M$, while for a plant of 20 MW these values are 0.26 M$ and 0.19 M$, respectively

  18. Construction Progress of S-IC Test Stand Towers

    Science.gov (United States)

    1963-01-01

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army's Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photograph taken April 17, 1963, gives a look at the four tower legs of the S-IC test stand at their completed height.

  19. Construction Progress of the S-IC Test Stand Tower

    Science.gov (United States)

    1963-01-01

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army's Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photograph, taken from ground level on May 7, 1963, gives a close look at one of the four towers legs of the S-IC test stand nearing its completed height.

  20. Construction Progress of the S-IC Test Stand Towers

    Science.gov (United States)

    1963-01-01

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army's Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. This photograph, taken April 4, 1963, gives a close up look at the ever-growing four towers of the S-IC Test Stand.

  1. Cellular Phone Towers, File name = CELLTOWERS Contains point file of cell towers and an inclomplete poly cadastral layer of properties with cell towers. http://www.harfordcountymd.gov/gis/Index.cfm, Published in 2011, 1:1200 (1in=100ft) scale, Harford County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Cellular Phone Towers dataset current as of 2011. File name = CELLTOWERS Contains point file of cell towers and an inclomplete poly cadastral layer of properties...

  2. Cellular Phone Towers, FCC registered communications towers. Points were generated from FCC data latlong. Originally created as a basis of comparison for Appraiser's cell tower points, bu comparison was inconclusive. Represented all registered FCC sites as of 6/26/2003. No, Published in 2003, 1:1200 (1in=100ft) scale, Sedgwick County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Cellular Phone Towers dataset current as of 2003. FCC registered communications towers. Points were generated from FCC data latlong. Originally created as a basis of...

  3. Bottom nozzle of a LWR fuel assembly

    International Nuclear Information System (INIS)

    Leroux, J.C.

    1991-01-01

    The bottom nozzle consists of a transverse element in form of box having a bending resistant grid structure which has an outer peripheral frame of cross-section corresponding to that of the fuel assembly and which has walls defining large cells. The transverse element has a retainer plate with a regular array of openings. The retainer plate is fixed above and parallel to the grid structure with a spacing in order to form, between the grid structure and the retainer plate a free space for tranquil flow of cooling water and for debris collection [fr

  4. Control Properties of Bottom Fired Marine Boilers

    DEFF Research Database (Denmark)

    Solberg, Brian; Andersen, Palle; Karstensen, Claus M. S.

    2005-01-01

    This paper focuses on model analysis of a dynamic model of a bottom fired one-pass smoke tube boiler. Linearised versions of the model are analysed to determine how gain, time constants and right half plane zeros (caused by the shrink-and-swell phenomenon) depend on the steam flow load. Furthermore...... the interactions in the system are inspected to analyse potential benefit from using a multivariable control strategy in favour of the current strategy based on single loop theory. An analysis of the nonlinear model is carried out to further determine the nonlinear characteristics of the boiler system...

  5. Bottom loaded filter for radioactive liquids

    International Nuclear Information System (INIS)

    Wendland, W.G.

    1983-01-01

    This invention relates to equipment for filtering liquids and more particularly to filter assemblies for use with radioactive by-products of nuclear power plants. The invention provides a compact, bottom-loaded filter assembly that can be quickly and safely loaded and unloaded without the use of complex remote equipment. The assembly is integrally shielded and does not require external shielding. The closure hatch may be automatically aligned to facilitate quick sealing attachment after replacement of the filter cartridge, and the filter cartridge may be automatically positioned within the filter housing during the replacement operation

  6. A new kind of bottom quark factory

    International Nuclear Information System (INIS)

    Mtingwa, S.K.; Strikman, M.; AN SSSR, Leningrad

    1991-01-01

    We describe a novel method of producing large numbers of B mesons containing bottom quarks. It is known that one should analyze at least 10 9 B meson decays to elucidate the physics of CP violation and rare B decay modes. Using the ultra high energy electron beams from the future generation of electron linear colliders, we Compton backscatter low energy laser beams off these electron beams. From this process, we produce hot photons having energy hundreds of GeV. Upon scattering these hot photons onto stationary targets, we show that it is possible to photoproduce and measure the necessary 10 9 B mesons per year. 24 refs., 4 figs

  7. Top (and Bottom) asymmetries at the LHC

    CERN Document Server

    Pinamonti, Michele; The ATLAS collaboration

    2015-01-01

    The latest top pair production charge asymmetry measurements by the ATLAS and CMS Collaborations are presented: inclusive and differential measurements in the single lepton and dilepton channels based on the full 7 TeV data-set, a combination of the 7 TeV single lepton measurements by the two experiments, and a measurement in the single lepton channel on the full 8 TeV data-set performed by the CMS experiment. The first measurement of the bottom pair producion charge asymmetry by the LHCb experiment is also mentioned.

  8. Neoliberalism Viewed From the Bottom Up

    DEFF Research Database (Denmark)

    Danneris, Sophie

    2017-01-01

    Drawing on the assumption that it is pivotal to include a bottom up perspective to understand the way in which the welfare system functions, this chapter sets out to explore the lived experience of neoliberalism. The purpose is to gain insight into the consequences of neoliberalism from...... the viewpoint of the vulnerable benefit claimants who encounter it on a daily basis. The analysis is based on a qualitative longitudinal study conducted from 2013 to 2015, which shows how, in varying ways, clients routinely cope with being part of a neoliberal welfare state: by resignation, by taking action...

  9. Revisiting the round bottom flask rainbow experiment

    Science.gov (United States)

    Selmke, Markus; Selmke, Sarah

    2018-01-01

    A popular demonstration experiment in optics uses a round-bottom flask filled with water to project a circular rainbow on a screen with a hole through which the flask is illuminated. We show how the vessel's wall shifts the first- and second-order bows towards each other and consequently reduces the width of Alexander's dark band. We address the challenge this introduces in observing Alexander's dark band, and explain the importance of a sufficient distance between the flask and the screen. The wall-effect also introduces a splitting of the bows that can easily be misinterpreted.

  10. NLO QCD corrections to top anti-top bottom anti-bottom production at the LHC

    CERN Document Server

    Bredenstein, Axel; Dittmaier, Stefan; Pozzorini, Stefano

    2010-01-01

    The next-to-leading order (NLO) QCD corrections to top anti-top bottom anti-bottom (tTbB) production at the LHC reveal that the scale choice adopted in previous lowest-order simulations underestimates the tTbB cross section by a factor two. We discuss a new dynamical scale that stabilizes the perturbative predictions and describe the impact of the corrections on the shape of distributions. We also account for the techniques employed to compute the six-particle one-loop amplitudes with high CPU efficiency.

  11. Fresh Bottom Ash Characteristics Dependence on Fractional Composition

    OpenAIRE

    Jurgita Seniūnaitė; Saulius Vasarevičius

    2017-01-01

    Waste incineration process generates two main by-products streams: fly ash and bottom ash. Bottom ash is composed of a variety of oxides, heavy metals and salts. Chemical materials distributed unevenly in different fractions of bottom ash. This study investigates the heavy metals (Pb, Cd) content dependence of bottom ash and fraction composition. Studies were performed with five different fractions (0–2 mm; 2–5.6 mm; 5.6–11.2 mm; 11.2–22,4 mm; 22.4–40 mm) of fresh bottom ash. After a one-step...

  12. Skywards - climate design for the Moscow Federation Tower; Dem Himmel entgegen - Klimadesign fuer den Federation Tower Moskau

    Energy Technology Data Exchange (ETDEWEB)

    Reiser, Claudius [Ebert-Ingenieure GmbH and Co. KG, Competence Center Nachhaltiges Bauen, Nuernberg (Germany)

    2008-06-15

    Advanced simulation tools were used in developing the climate design for the roof covering the taller of the two blocks at Moscow's Federation Tower. The all-glass roof space at a height of 365 m is designed to accommodate the finest and most exclusive hotel areas. Several restaurants, bars and lounges and a Sky Dance Club will offer entertainment and fabulous views across the whole city. Simulations were used to develop and verify a design that ensures thermal comfort taking into account architectural, climate and utilisation requirements. The structure and the building services were simulated based on a 3D model, and simulations were carried out for summer and winter scenarios. This paper describes the design process including load calculations and the development and assessment of the climate design by means of simulation. (Abstract Copyright [2008], Wiley Periodicals, Inc.) [German] In der Entwicklung des Klimakonzeptes der Turmkappe Ost des Federation Towers in Moskau wurden modernste Simulationswerkzeuge eingesetzt. Die vollstaendig glaeserne Turmkappe in 365 m Hoehe soll Raum fuer einen der schoensten und exklusivsten Bereiche des Hotels geben. Diverse Restaurants, Bars und Lounges sowie ein Sky Dance Club sollen einmal zum Verweilen und zur naechtlichen Vergnuegung einladen und dabei stets einen traumhaften Blick ueber die gesamte Stadt ermoeglichen. Mit Hilfe der Simulation wurde fuer die Turmkappe ein Klimakonzept entwickelt und ueberprueft, das die thermische Behaglichkeit unter Beruecksichtigung von Architektur, Klima und Nutzung gewaehrleistet. Dazu wurde die Architektur inklusive der Klimatechnik in einem 3D-Modell abgebildet und fuer den Sommer- und Winterfall berechnet. Der vorliegende Beitrag vollzieht den Planungsablauf von der Lastberechnung bis hin zur Erstellung und Bewertung des Klimakonzeptes in der Simulation. (Abstract Copyright [2008], Wiley Periodicals, Inc.)

  13. The petroleum industry improving the bottom line

    International Nuclear Information System (INIS)

    Benner, R.I.

    1992-01-01

    The oil and gas exploration and production business environment has presented many challenges over the last decade, notably price volatility and rising costs. Managing the margin and changing a company's cost structure to improve the bottom line is a major issue with company executives. The experiences of Oryx Energy Company since its spinoff from Sun Company in 1988 are used as an example of a company makeover. A generalized exploration and production income statement is employed to present industry cost/portfolio relationships and strategies for improving the bottom line. At Oryx, three major strategies were set in place to enhance shareholder value: an increased emphasis on applied technology, including horizontal drilling, advanced 3-dimensional seismic prospecting, and intensive use of interactive computer workstations; international expansion; and an emphasis on the U.S. Gulf of Mexico, deemphasizing the onshore U.S. and the gas processing business. Specific strategies are outlined in the areas of increasing revenues, reducing production cost and exploration expense, and controlling general and administrative expenses. 8 refs., 18 figs., 2 tabs

  14. The Metric Documentation of Cham Towers in Vietnam by Spherical Photogrammetry

    Science.gov (United States)

    Fangi, G.; Malinverni, E. S.; Tassetti, A. N.

    2013-07-01

    The Università Politecnica delle Marche is charged of the study, survey and documentation of the Chan towers in Vietnam. The towers are spread near the coastline from latitude 16° 30', to latitude of 10° 56'. The Champa civilization flourished from 8th century till 17th century produced the Cham towers, places of religious worship. The ancient Cham people created a developed culture expressed in the architecture in the towers, which were Buddhist temples. Roughly there are six different architectonic styles and two different layouts in plan. One lay-out is that one main tower is surrounded by smaller service buildings, like walls, doors, gates; the other layout is a set of three aligned towers. We carried out the documentation with three different techniques, laser scanning, dense point clouds generation with SfM (Structure from Motion) algorithm, and mainly by Panoramic Spherical Photogrammetry (PSP). Laser scanning is indeed the best instrument but sometimes its availability is very limited for different practical and logistic reasons. The point cloud generation produced good results, but it has some problems and limitations of management too. On the other hand PSP is very quick technique in the taking phase, but the restitution is rather slow. PSP is suitable for a good metric documentation, making the Cham tower project the main project of documentation executed with spherical photogrammetry.

  15. Alternative geometry for cylindrical natural draft cooling tower with higher cooling efficiency under crosswind condition

    International Nuclear Information System (INIS)

    Goodarzi, M.; Ramezanpour, R.

    2014-01-01

    Highlights: • Alternative cross sections for natural draft cooling tower were proposed. • Numerical solution was applied to study thermal and hydraulic performances. • Thermal and hydraulic performances were assessed by comparative parameters. • Cooling tower with elliptical cross section had better thermal performance under crosswind. • It could successfully used at the regions with invariant wind direction. - Abstract: Cooling efficiency of a natural draft dry cooling tower may significantly decrease under crosswind condition. Therefore, many researchers attempted to improve the cooling efficiency under this condition by using structural or mechanical facilities. In this article, alternative shell geometry with elliptical cross section is proposed for this type of cooling tower instead of usual shell geometry with circular cross section. Thermal performance and cooling efficiency of the two types of cooling towers are numerically investigated. Numerical simulations show that cooling tower with elliptical cross section improves the cooling efficiency compared to the usual type with circular cross section under high-speed wind moving normal to the longitudinal diameter of the elliptical cooling tower

  16. Hexcrete Tower for Harvesting Wind Energy at Taller Hub Heights - Budget Period 2

    Energy Technology Data Exchange (ETDEWEB)

    Sritharan, Sri [Iowa State Univ., Ames, IA (United States)

    2017-05-01

    Interest in designing taller towers for wind energy production in the United States (U.S.) has been steadily growing. In May 2015, it was revealed that taller towers will make wind energy production a reality in all 50 states, including some states that have nearly zero renewables in their energy portfolio. Facilitating wind energy production feasibility in all 50 states will no doubt contribute to increasing the electricity produced by wind from 4.5% in 2013 to a targeted scenario of 35% by 2050 in the Wind Vision report. This project focuses on the Hexcrete tower concept developed for tall towers using High Strength Concrete (HSC) and/or Ultra-High Performance Concrete (UHPC). Among other benefits, the Hexcrete concept overcomes transportation and logistical challenges, thus facilitating construction of towers with hub heights of 100-m (328-ft) and higher. The goal of this project is to facilitate widespread deployment of Hexcrete towers for harvesting wind energy at 120 to 140-m (394 to 459-ft) hub heights and reduce the Levelized Cost of Energy (LCOE) of wind energy production in the U.S. The technical scope of the project includes detailed design and optimization of at least three wind turbine towers using the Hexcrete concept together with experimental validation and LCOE analyses and development of a commercialization plan.

  17. Improved reliability of wind turbine towers with active tuned mass dampers (ATMDs)

    Science.gov (United States)

    Fitzgerald, Breiffni; Sarkar, Saptarshi; Staino, Andrea

    2018-04-01

    Modern multi-megawatt wind turbines are composed of slender, flexible, and lightly damped blades and towers. These components exhibit high susceptibility to wind-induced vibrations. As the size, flexibility and cost of the towers have increased in recent years, the need to protect these structures against damage induced by turbulent aerodynamic loading has become apparent. This paper combines structural dynamic models and probabilistic assessment tools to demonstrate improvements in structural reliability when modern wind turbine towers are equipped with active tuned mass dampers (ATMDs). This study proposes a multi-modal wind turbine model for wind turbine control design and analysis. This study incorporates an ATMD into the tower of this model. The model is subjected to stochastically generated wind loads of varying speeds to develop wind-induced probabilistic demand models for towers of modern multi-megawatt wind turbines under structural uncertainty. Numerical simulations have been carried out to ascertain the effectiveness of the active control system to improve the structural performance of the wind turbine and its reliability. The study constructs fragility curves, which illustrate reductions in the vulnerability of towers to wind loading owing to the inclusion of the damper. Results show that the active controller is successful in increasing the reliability of the tower responses. According to the analysis carried out in this paper, a strong reduction of the probability of exceeding a given displacement at the rated wind speed has been observed.

  18. Structural inspection and wind analysis of redwood cooling towers at the Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    Chung, T.; Solack, T.; Hortel, J.

    1991-01-01

    As part of the plant upgrade program, structural analyses and field inspections were performed on four redwood cooling towers at the DOE Portsmouth gaseous diffusion plant located in Piketon, Ohio. The cooling towers are categorized as important hazard facilities. The loadings are derived from UCRL-15910 according to the pertinent hazard category. In addition to the seismic and wind loadings, the wood cooling towers are constantly subject to adverse environmental effects such as elevated temperature, chemical attack, icing and snow load, and motor vibrations. A thorough structural evaluation for all load combinations was performed for each of the cooling towers based on the structural code requirements of the Cooling Tower Institute and National Forest Products Association. Most stress criteria are unique for the redwood material. This evaluation was performed using finite element techniques on the global structural integrity and supplemented by hand calculations on the individual connection joints. Overloaded wood structural members and joints are identified by the analysis. The rectangular tower structure sits on a concrete basin that span across 60 ft by 200 ft. A major part of the cooling towers upgrading program involved field inspections of the individual cells of each tower. The primary purpose of these inspections was to identify any existing structural damage or deficiencies such as failed members, degraded wood, and deficiencies resulting from poor construction practice. Inspection of 40 cells identified some generic deficiencies that mostly are consistent with the analytical finding. Based on the analysis, some effective but inexpensive upgrading techniques were developed and recommended to bring the cooling towers into compliance with current DOE requirements

  19. Three years of vertically resolved CO2/CH4/CO measurements at the tallest tower in the Amazon - Amazonian Tall Tower Observatory (ATTO, Brazil)

    Science.gov (United States)

    Valentin Lavrič, Jošt; Winderlich, Jan; Walter, David; Chi, Xuguang; Andreae, Meinrat O.; Heimann, Martin

    2015-04-01

    The 330 m-tall tower that is currently in its final phase of construction at the Amazonian Tall Tower Observatory (ATTO, Brazil; 2° 08'S, 59° 00'W), is the counterpart of the 304 m-tall tower of the Zotino Tall Tower Observatory tower (ZOTTO), located in central Siberia (Russia; 60° 48'N, 89° 21'E). The ATTO tall tower will extend above the atmospheric surface layer and the nocturnal stable boundary layer, and aims at delivering ground breaking findings that will be the basis for improved climate models. While awaiting the completion of the tall tower, a number of campaign or continuous pilot measurements are taking place on the ATTO site at and around the currently tallest Amazonian tower and mast (80 m a.g.l.). Since March 2012, we run continuous high precision CO2/CH4/CO measurements in an air-conditioned container at the foot of the 80 m tower. The sample air inlets are installed at five levels; 79, 53, 38, 24, and 4 m a.g.l. Two frequently calibrated CRDS analyzers (G1301 and G1302; Picarro Inc., USA) are used for measuring CO2/CH4 and CO/CO2, respectively. Even if due to proximity of our measurements to the canopy (~ 35 m a.g.l.) the data is influenced by local sources and sinks, it still provides a valuable insight into the diurnal and seasonal variations of the measured gas species. Additionally, the data set has proven to be also interesting combined with the parameters that are measured by other groups at the site in parallel either continuously or during intensive observation periods (e.g. VOCs, reactive trace gases, aerosols). A first analysis of the available data is presented. Our work was performed within the frame of the German-Brazilian project ATTO and supported by the federal government agencies BMBF and MCT (Grant number BMBF 01LB1001A). We acknowledge the fundamental support by the Max Planck Society, INPA and UEA. Special thanks go to the Amazonas State SDS/CEUC-RDS Uatumã.

  20. Static and Motion-Based Visual Features Used by Airport Tower Controllers: Some Implications for the Design of Remote or Virtual Towers

    Science.gov (United States)

    Ellis, Stephen R.; Liston, Dorion B.

    2011-01-01

    Visual motion and other visual cues are used by tower controllers to provide important support for their control tasks at and near airports. These cues are particularly important for anticipated separation. Some of them, which we call visual features, have been identified from structured interviews and discussions with 24 active air traffic controllers or supervisors. The visual information that these features provide has been analyzed with respect to possible ways it could be presented at a remote tower that does not allow a direct view of the airport. Two types of remote towers are possible. One could be based on a plan-view, map-like computer-generated display of the airport and its immediate surroundings. An alternative would present a composite perspective view of the airport and its surroundings, possibly provided by an array of radially mounted cameras positioned at the airport in lieu of a tower. An initial more detailed analyses of one of the specific landing cues identified by the controllers, landing deceleration, is provided as a basis for evaluating how controllers might detect and use it. Understanding other such cues will help identify the information that may be degraded or lost in a remote or virtual tower not located at the airport. Some initial suggestions how some of the lost visual information may be presented in displays are mentioned. Many of the cues considered involve visual motion, though some important static cues are also discussed.

  1. Wind Turbine Rotor-Tower Interaction Using an Incompressible Overset Grid Method

    DEFF Research Database (Denmark)

    Zahle, Frederik; Sørensen, Niels N.; Johansen, Jeppe

    2009-01-01

    are in good agreement with the experimental data available. The interaction between the rotor and the tower induces significant increases in the transient loads on the blades and is characterized by an instant deloading and subsequent reloading of the blade, associated with the velocity deficit in the wake......, combined with the interaction with the shed vortices, which causes a strongly time-varying response. Finally, the results show that the rotor has a strong effect on the tower shedding frequency, causing under certain flow conditions vortex lock-in to take place on the upper part of the tower. Copyright...

  2. Study on Remote Monitoring System of Crossing and Spanning Tangent Tower

    Science.gov (United States)

    Chen, Da-bing; Zhang, Nai-long; Zhang, Meng-ge; Wang, Ze-hua; Zhang, Yan

    2017-05-01

    In order to grasp the vibration state of overhead transmission line and ensure the operational security of transmission line, the remote monitoring system of crossing and spanning tangent tower was studied. By use of this system, the displacement, velocity and acceleration of the tower, and the local weather data are collected automatically, displayed on computer of remote monitoring centre through wireless network, real-time collection and transmission of vibration signals are realized. The applying results show that the system is excellent in reliability and accuracy and so on. The system can be used to remote monitoring of transmission tower of UHV power transmission lines and in large spanning areas.

  3. Design and Manufacturing of Composite Tower Structure for Wind Turbine Equipment

    Science.gov (United States)

    Park, Hyunbum

    2018-02-01

    This study proposes the composite tower design process for large wind turbine equipment. In this work, structural design of tower and analysis using finite element method was performed. After structural design, prototype blade manufacturing and test was performed. The used material is a glass fiber and epoxy resin composite. And also, sand was used in the middle part. The optimized structural design and analysis was performed. The parameter for optimized structural design is weight reduction and safety of structure. Finally, structure of tower will be confirmed by structural test.

  4. Ecological impact of chloro-organics produced by chlorination of cooling tower waters

    Energy Technology Data Exchange (ETDEWEB)

    Jolley, R L; Cumming, R B; Pitt, W W; Taylor, F G; Thompson, J E; Hartmann, S J

    1977-01-01

    Experimental results of the initial assessment of chlorine-containing compounds in the blowdown from cooling towers and the possible mutagenic activity of these compounds are reported. High-resolution liquid chromatographic separations were made on concentrates of the blowdown from the cooling tower at the High Flux Isotope Reactor (HFIR) and from the recirculating water system for the cooling towers at the Oak Ridge Gaseous Diffusion Plant (ORGDP), Oak Ridge, Tennessee. The chromatograms of chlorinated cooling waters contained numerous uv-absorbing and cerate-oxidizable constituents that are now being processed through a multicomponent identification procedure. Concentrates of the chlorinated waters are also being examined for mutagenic activity.

  5. Estimates of bottom roughness length and bottom shear stress in South San Francisco Bay, California

    Science.gov (United States)

    Cheng, R.T.; Ling, C.-H.; Gartner, J.W.; Wang, P.-F.

    1999-01-01

    A field investigation of the hydrodynamics and the resuspension and transport of participate matter in a bottom boundary layer was carried out in South San Francisco Bay (South Bay), California, during March-April 1995. Using broadband acoustic Doppler current profilers, detailed measurements of turbulent mean velocity distribution within 1.5 m above bed have been obtained. A global method of data analysis was used for estimating bottom roughness length zo and bottom shear stress (or friction velocities u*). Field data have been examined by dividing the time series of velocity profiles into 24-hour periods and independently analyzing the velocity profile time series by flooding and ebbing periods. The global method of solution gives consistent properties of bottom roughness length zo and bottom shear stress values (or friction velocities u*) in South Bay. Estimated mean values of zo and u* for flooding and ebbing cycles are different. The differences in mean zo and u* are shown to be caused by tidal current flood-ebb inequality, rather than the flooding or ebbing of tidal currents. The bed shear stress correlates well with a reference velocity; the slope of the correlation defines a drag coefficient. Forty-three days of field data in South Bay show two regimes of zo (and drag coefficient) as a function of a reference velocity. When the mean velocity is >25-30 cm s-1, the ln zo (and thus the drag coefficient) is inversely proportional to the reference velocity. The cause for the reduction of roughness length is hypothesized as sediment erosion due to intensifying tidal currents thereby reducing bed roughness. When the mean velocity is <25-30 cm s-1, the correlation between zo and the reference velocity is less clear. A plausible explanation of scattered values of zo under this condition may be sediment deposition. Measured sediment data were inadequate to support this hypothesis, but the proposed hypothesis warrants further field investigation.

  6. Science education in rural America: Adaptations for the ivory tower

    Science.gov (United States)

    van Doren, Gregory S.

    This thesis illustrated what can happen when academic culture disconnects from the cultures surrounding it. It showed that formal school environments are not always the best places to learn. A discussion of the debate between coherence and fragmentation learning theories illustrated academic chasms and a mindset that science education must originate from within ivory towers to be valued. Rationales for place-based science education were developed. Two National Science Foundation initiatives were compared and contrasted for relevance to Native Science education (a) Informal Science Education and (b) Science Education for New Civic Engagement and Responsibilities. A National Science Foundation instrument, known as the Self-Assessment of Learning Gains, was selected to field-test measures of learning science outside of university science courses. Principles of chemistry were taught in community workshops, and those participant self-assessments were compared to self-assessments of students in introductory chemistry courses at two universities. University students consistently claimed the greatest learning gains, in the post-course survey, for the same areas that they claimed to have the greatest understanding, in the pre-course survey. The workshop participant responses differed, depending upon location of the learning environment. When held in a university laboratory, ideas were not related to other cultures, even when a Native Elder was present to describe those relationships. When held in a cultural center, those relationships were among the highest learning gains claimed. One of the instrument's greatest assets was the ability to measure reactions, level 4 of Bennett's (1976) hierarchy of evidence for program evaluation. A long-term commitment to informal science education (not short-term exhibits or programs), combined with negotiated place-based education was recommended as a crucially needed initiative, if relationships between universities and Native American

  7. Designing the organisational chart from the bottom

    DEFF Research Database (Denmark)

    Giangreco, Antonio; Carugati, Andrea

    and control. Marco had been called in because of his reputation for being an effective innovator with unconventional ideas for the public sector. Previously, during his long career in the civil service, Marco proved to be an effective leader and negotiator who was open to other people's view points. He would...... share any significant and final decisions with his employees, rather than merely imposing his own personal choice. After spending some time in the organisation, he put into action a bottom up method to redesign the structure of the HR department. He decided to temporarily suspend the existing internal...... organisation and involve all the HR employees in its redesign, starting with a list of work related activities that they had identified. If on one hand this method was energy and time consuming, on the other, the new design would have greater chances of being adopted enthusiastically by his employees....

  8. Bottom loaded filter for radioactive liquid

    International Nuclear Information System (INIS)

    Wendland, W.G.

    1980-01-01

    A specification is given for a bottom loaded filter assembly for filtering radioactive liquids through a replaceable cartridge filter, which includes a lead-filled jacket enveloping a housing having a chamber therein for the filter cartridge. A track arrangement carries a hatch for sealing the chamber. A spacer plug supports the cartridge within guide means associated with the inlet conduit in the chamber. The plug and cartridge drop out of the chamber when the hatch is unbolted and moved laterally of the chamber along the track. During cartridge replacement a new plug and cartridge are supported in the guide means by a spacer bar inserted across the track means under the chamber. The hatch is then slid under the chamber and bolted to a flange on the housing, engaging an O-ring to seal the chamber. (author)

  9. Analysis of Peach Bottom turbine trip tests

    International Nuclear Information System (INIS)

    Cheng, H.S.; Lu, M.S.; Hsu, C.J.; Shier, W.G.; Diamond, D.J.; Levine, M.M.; Odar, F.

    1979-01-01

    Current interest in the analysis of turbine trip transients has been generated by the recent tests performed at the Peach Bottom (Unit 2) reactor. Three tests, simulating turbine trip transients, were performed at different initial power and coolant flow conditions. The data from these tests provide considerable information to aid qualification of computer codes that are currently used in BWR design analysis. The results are presented of an analysis of a turbine trip transient using the RELAP-3B and the BNL-TWIGL computer codes. Specific results are provided comparing the calculated reactor power and system pressures with the test data. Excellent agreement for all three test transients is evident from the comparisons

  10. Bringing corporate culture to the bottom line.

    Science.gov (United States)

    Denison, D R

    1984-01-01

    Up to now managers could find little evidence to support the idea that the organization's culture has an impact on its bottom-line performance. To remedy this, Denison draws on survey and performance data from 34 large corporations to show that those that have participative cultures experience better performance than those that do not. This difference in performance appears to have widened over the five years that these firms were studied. The results also hold up when the performance measures for each firm (return on investment and return on sales) are compared with those of their competitors. Denison suggests that this comparative approach to the study of organizational culture provides a way to capture the impact that culture has on organizational performance. This strategy, he argues, also provides a way of diagnosing organizations and measuring the ways in which human resources management, organizational culture, and management practices do, in fact, contribute to the success of business organizations.

  11. Control Properties of Bottom Fired Marine Boilers

    DEFF Research Database (Denmark)

    Solberg, Brian; Andersen, Palle; Karstensen, Claus M. S.

    2007-01-01

    This paper focuses on model analysis of a dynamic model of a bottom fired one-pass smoke tube boiler. Linearized versions of the model are analyzed and show large variations in system gains at steady state as function of load whereas gain variations near the desired bandwidth are small. An analysis...... of the potential benefit from using a multivariable control strategy in favor of the current strategy based on single loop theory is carried out and proves that the interactions in the system are not negligible and a subsequent controller design should take this into account. A design using dynamical decoupling...... showed substantial improvement compared to a decentralized scheme based on sequential loop closing. Similar or better result is expected to be obtainable using a full Multiple input Multiple output scheme. Furthermore closed loop simulations, applying a linear controller to the nonlinear plant model...

  12. Control Properties of Bottom Fired Marine Boilers

    DEFF Research Database (Denmark)

    Solberg, Brian; Andersen, Palle; Karstensen, Claus M. S.

    2005-01-01

    This paper focuses on model analysis of a dynamic model of a bottom fired one-pass smoke tube boiler. Linearised versions of the model are analysed to determine how gain, time constants and right half plane zeros (caused by the shrink-and-swell phenomenon) depend on the steam flow load. Furthermore...... the interactions in the system are inspected to analyse potential benefit from using a multivariable control strategy in favour of the current strategy based on single loop theory. An analysis of the nonlinear model is carried out to further determine the nonlinear characteristics of the boiler system...... and to verify whether nonlinear control is needed. Finally a controller based on single loop theory is used to analyse if input constraints become active when rejecting transient behaviour from the disturbance steam flow. The model analysis shows large variations in system gains at steady state as function...

  13. BC Hydro triple bottom line report 2002

    Energy Technology Data Exchange (ETDEWEB)

    Anon

    2002-08-01

    British Columbia Hydro (BC Hydro) published this document which measures the environmental, social and economic performance of the company. It is a complement to BC Hydro's 2002 Annual Report. The report was prepared to better understand the company's business in terms of its commitment to being an environmentally, socially, and economically responsible company (the three bottom lines). BC Hydro proved its ability to integrate the three bottom lines in decision making processes by carefully examining the environmental, social and economical impacts of programs such as Power Smart, Green and Alternative Energy, and Water Use Planning. All indicators point to BC Hydro achieving its commitment of providing a minimum of 10 per cent of new demand through 2010 with new green energy sources. Water Use Plans were developed for hydroelectric generating stations, and they should all be in place by 2003. Efficiencies realised through the Power Smart program offset the increases in greenhouse gas associated with increased energy demand. Juvenile sturgeon raised in a hatchery were released into the Columbia River in May 2002. The completion of a 40-kilometre trail on the Sunshine Coast was helped by a financial contribution from BC Hydro in the amount of 23,000 dollars. Safety improvements were implemented at eight facilities, such as dam remediation, dam surveillance and instrumentation updates. Scholarships were awarded across the province, along with additional donations to non-profit organizations. Co-op positions were provided for 150 students. Internal energy efficiency programs were successful. Planning is under way for significant maintenance work and equipment replacement projects as the transmission and distribution infrastructure ages. The number of reported indicators was expanded this year. In turn, they were aligned with the revised Global Reporting Initiative (GRI) guidelines. tabs.

  14. BC Hydro triple bottom line report 2002

    International Nuclear Information System (INIS)

    Anon

    2002-08-01

    British Columbia Hydro (BC Hydro) published this document which measures the environmental, social and economic performance of the company. It is a complement to BC Hydro's 2002 Annual Report. The report was prepared to better understand the company's business in terms of its commitment to being an environmentally, socially, and economically responsible company (the three bottom lines). BC Hydro proved its ability to integrate the three bottom lines in decision making processes by carefully examining the environmental, social and economical impacts of programs such as Power Smart, Green and Alternative Energy, and Water Use Planning. All indicators point to BC Hydro achieving its commitment of providing a minimum of 10 per cent of new demand through 2010 with new green energy sources. Water Use Plans were developed for hydroelectric generating stations, and they should all be in place by 2003. Efficiencies realised through the Power Smart program offset the increases in greenhouse gas associated with increased energy demand. Juvenile sturgeon raised in a hatchery were released into the Columbia River in May 2002. The completion of a 40-kilometre trail on the Sunshine Coast was helped by a financial contribution from BC Hydro in the amount of 23,000 dollars. Safety improvements were implemented at eight facilities, such as dam remediation, dam surveillance and instrumentation updates. Scholarships were awarded across the province, along with additional donations to non-profit organizations. Co-op positions were provided for 150 students. Internal energy efficiency programs were successful. Planning is under way for significant maintenance work and equipment replacement projects as the transmission and distribution infrastructure ages. The number of reported indicators was expanded this year. In turn, they were aligned with the revised Global Reporting Initiative (GRI) guidelines. tabs

  15. Energy study of a medieval tower, restored as a museum

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulos, A.M.; Avgelis, A. [Aristotle University of Thessaloniki (Greece). Dept. of Mechanical Engineering; Santamouris, M. [National Kapodestrean University, Athens (Greece). Dept. of Applied Physics

    2003-10-01

    Museums are buildings of particular significance due to their function and their status. At the same time they are buildings in which the principles of energy conservation are rarely applied, sometimes without reason. It has been decided by the Hellenic Ministry of Culture to convert a medieval tower, built in the year 1344 as a fortress with 0.8-1.5 m thick walls and almost no windows, into a museum. The present paper discusses the difficulties that arise in the attempt to balance between the indoor climate conditions necessary to protect the exhibits and to provide comfortable conditions to the visitors, whilst respecting the aesthetics and the historical significance of the building. Furthermore, one needs to consider the difficult but necessary task of assessing factors such as the building's shell's thermal conductivity and capacity, the ventilation necessary as well as the indoor air movement, in order to determine the cooling loads. Finally, the challenge lies in designing and dimensioning an effective and efficient HVAC system, which should be as discrete as possible. The present paper aims to present the results of the study, to discuss the expected energy behaviour of the building and to comment on the options for introducing energy conservation techniques. (author)

  16. Bald eagles view their territory from high tower at KSC

    Science.gov (United States)

    2000-01-01

    A pair of Florida bald eagles take advantage of a tower to rest and view the landscape near the intersection of the NASA Causeway and Kennedy Parkway North at Kennedy Space Center. This pair of eagles nests near Kennedy Parkway and is seen frequently by KSC commuters and visitors. The Southern Bald Eagle ranges throughout Florida and along the coasts of California, Texas, Louisiana and the south Atlantic states. Bald Eagles are listed as endangered in the U.S., except in five states where they are listed as threatened. The number of nesting pairs of the southern race once numbered several thousand; recent estimates are only 350-375. Most southern Florida eagles nesting at KSC arrive during late summer and leave for the north in late spring. They move to nest sites in October and November and lay one to three eggs. The young fledge from February to April. . Kennedy Space Center shares a boundary with the Merritt Island National Wildlife Refuge, which encompasses 92,000 acres that are a habitat for more than 331 species of birds, 31 mammals, 117 fishes, and 65 amphibians and reptiles. The marshes and open water of the refuge provide wintering areas for 23 species of migratory waterfowl, as well as a year-round home for great blue herons, great egrets, wood storks, cormorants, brown pelicans and other species of marsh and shore birds, as well as a variety of insects.

  17. Modified Drop Tower Impact Tests for American Football Helmets.

    Science.gov (United States)

    Rush, G Alston; Prabhu, R; Rush, Gus A; Williams, Lakiesha N; Horstemeyer, M F

    2017-02-19

    A modified National Operating Committee on Standards for Athletic Equipment (NOCSAE) test method for American football helmet drop impact test standards is presented that would provide better assessment of a helmet's on-field impact performance by including a faceguard on the helmet. In this study, a merger of faceguard and helmet test standards is proposed. The need for a more robust systematic approach to football helmet testing procedures is emphasized by comparing representative results of the Head Injury Criterion (HIC), Severity Index (SI), and peak acceleration values for different helmets at different helmet locations under modified NOCSAE standard drop tower tests. Essentially, these comparative drop test results revealed that the faceguard adds a stiffening kinematic constraint to the shell that lessens total energy absorption. The current NOCSAE standard test methods can be improved to represent on-field helmet hits by attaching the faceguards to helmets and by including two new helmet impact locations (Front Top and Front Top Boss). The reported football helmet test method gives a more accurate representation of a helmet's performance and its ability to mitigate on-field impacts while promoting safer football helmets.

  18. Grenfell Tower fire - a tragic case study in health inequalities.

    Science.gov (United States)

    Watt, R G

    2017-11-01

    At least 80 people died in the recent Grenfell Tower fire in Kensington and Chelsea, West London. This incident has provoked much anger, debate and reflection on how such a tragedy could happen in London, one of the richest cities in the world. Seen through a public health lens, this disaster is ultimately about social inequality in modern Britain. Kensington and Chelsea is a deeply divided community, where many billionaires and very wealthy people live cheek by jowl with poor and disenfranchised people struggling to make ends meet. It is therefore not a surprise that such a terrible incident should happen in this socially unequal setting where very stark health inequalities already exist. This paper explores some of the broader underlying factors that may have contributed to this tragedy, the political determinants of health. As these factors are linked to both general and oral health inequalities, the lessons learnt from this incident have direct relevance and salience to oral health professionals concerned about tackling social inequalities in contemporary society.

  19. Calibration corrections of solar tower flux density measurements

    International Nuclear Information System (INIS)

    Ulmer, Steffen; Luepfert, Eckhard; Pfaender, Markus; Buck, Reiner

    2004-01-01

    The PSA flux density measuring system PROHERMES measures the concentrated solar radiation in the entrance aperture of solar tower receivers with a white rotating bar as target and a CCD-camera taking images. The calibration is done with commercial flux gauges placed in the measurement plane. To improve the calibration of the system and to reveal systematic errors, measurements are performed with two different types of commercial flux gauges (Thermogage sensors with and without quartz window) and a large custom-made calorimeter used as reference. The comparison shows that the sensors without quartz window measure about 5-8% higher and the sensors with quartz window about 100% higher. This error is explained with the differences in the spectral composition of the radiation and different angles of incidence between the manufacturer calibration and the solar measurements and corrections are proposed. Spectral changes of the sunlight during the day and year can affect the measurements by more than 10%. By selecting a correction filter adapted to the camera sensitivity, this influence can be reduced to less than 2.5%. Due to the reflective properties of the target coating, changes in angle of incidence can affect the measurements. In standard solar field conditions, this error is less than 0.5%, but for special conditions a correction of the systematic error of up to 8% is proposed

  20. The Towers Watson Approach to Improving Corporate Wellness.

    Science.gov (United States)

    Wootton, Adam

    2012-06-01

    Encouraging employees to take care of their health is in the interests of everyone. Employees benefit from being healthier and happier, employers benefit from having an engaged workforce, lower absenteeism, and lower medical costs, and society as a whole benefits from using less medical resources. Employers have been trying to push healthy messages to employees for a long time and have had some good success. For example, an increased emphasis on the dangers of tobacco use in employer and government communications has helped bring about a significant decrease in smoking. However, overall population health in key risk areas (such as obesity and diabetes) continues to decline. These areas are where employers can really make a difference in health outcomes-and effective communications are critical to success. Towers Watson helps many companies educate employees about health and wellness and encourage more effective use of healthcare. The challenge is to find new and engaging ways to deliver this information so that employees take notice-and take action. After all, the amount of material employees receive on a daily basis from marketers, employers, and each other across the wide range of available media makes it extremely difficult to be heard. This is where gaming comes in-and why we think it's the tool to be incorporating into communication and engagement plans.

  1. Jülich solar power tower - system behavior during downtime

    Science.gov (United States)

    Baumann, Torsten; Göhring, Felix; Stadler, Hannes; Doerbeck, Till

    2017-06-01

    At the Jülich Solar Power Tower, two new shut-off dampers have been installed in the hot air piping system in order to reduce thermal losses during downtime of the plant. The thermodynamic behavior of the thermal energy storage and the steam boiler has been investigated with respect to heat losses after shut-down of the plant. Also, the change of temperature and the pressure drop at both shut-off dampers during downtime has been analyzed. Results show that for the storage, a reduction of thermal losses can be achieved by closing the damper overnight. Regarding the steam boiler, no improvements on heat losses were observed. If only two of the four storage chambers have been charged during operation, heat transfer between the chambers is observed after shut-down. It is concluded that natural convection is not the main source of thermal overnight losses, however, it can be lowered thanks to the dampers. Heat conduction and convectional heat transfer at the surfaces also contribute to the decrease of thermal energy, which can be lowered by thicker insulation layers in the future.

  2. CHEP2015: Dynamic Resource Allocation with arcControlTower

    CERN Document Server

    Filipcic, Andrej; The ATLAS collaboration; Nilsen, Jon Kerr

    2015-01-01

    Distributed computing resources available for high-energy physics research are becoming less dedicated to one type of workflow and researchers’ workloads are increasingly exploiting modern computing technologies such as parallelism. The current pilot job management model used by many experiments relies on static dedicated resources and cannot easily adapt to these changes. The model used for ATLAS in Nordic countries and some other places enables a flexible job management system based on dynamic resources allocation. Rather than a fixed set of resources managed centrally, the model allows resources to be requested on the fly. The ARC Computing Element (ARC-CE) and ARC Control Tower (aCT) are the key components of the model. The aCT requests jobs from the ATLAS job mangement system (Panda) and submits a fully-formed job description to ARC-CEs. ARC-CE can then dynamically request the required resources from the underlying batch system. In this paper we describe the architecture of the model and the experience...

  3. Dynamic Resource Allocation with the arcControlTower

    CERN Document Server

    Filipcic, Andrej; The ATLAS collaboration; Nilsen, Jon Kerr

    2015-01-01

    Distributed computing resources available for high-energy physics research are becoming less dedicated to one type of workflow and researchers’ workloads are increasingly exploiting modern computing technologies such as parallelism. The current pilot job management model used by many experiments relies on static dedicated resources and cannot easily adapt to these changes. The model used for ATLAS in Nordic countries and some other places enables a flexible job management system based on dynamic resources allocation. Rather than a fixed set of resources managed centrally, the model allows resources to be requested on the fly. The ARC Computing Element (ARC-CE) and ARC Control Tower (aCT) are the key components of the model. The aCT requests jobs from the ATLAS job management system (PanDA) and submits a fully-formed job description to ARC-CEs. ARC-CE can then dynamically request the required resources from the underlying batch system. In this paper we describe the architecture of the model and the experienc...

  4. Cooling tower and plume modeling for satellite remote sensing applications

    Energy Technology Data Exchange (ETDEWEB)

    Powers, B.J.

    1995-05-01

    It is often useful in nonproliferation studies to be able to remotely estimate the power generated by a power plant. Such information is indirectly available through an examination of the power dissipated by the plant. Power dissipation is generally accomplished either by transferring the excess heat generated into the atmosphere or into bodies of water. It is the former method with which we are exclusively concerned in this report. We discuss in this report the difficulties associated with such a task. In particular, we primarily address the remote detection of the temperature associated with the condensed water plume emitted from the cooling tower. We find that the effective emissivity of the plume is of fundamental importance for this task. Having examined the dependence of the plume emissivity in several IR bands and with varying liquid water content and droplet size distributions, we conclude that the plume emissivity, and consequently the plume brightness temperature, is dependent upon not only the liquid water content and band, but also upon the droplet size distribution. Finally, we discuss models dependent upon a detailed point-by-point description of the hydrodynamics and thermodynamics of the plume dynamics and those based upon spatially integrated models. We describe in detail a new integral model, the LANL Plume Model, which accounts for the evolution of the droplet size distribution. Some typical results obtained from this model are discussed.

  5. Observed and predicted cooling tower plume rise at the John E. Amos Power Plant, West Virginia

    International Nuclear Information System (INIS)

    Hanna, S.R.

    1977-01-01

    There is much current interest in cooling tower plume rise because of its importance in determining the environmental impact of cooling towers at planned power plants and industrial facilities. Some of the possible environmental problems related to heat and water emissions from cooling towers are drift deposition, ground level fog, cloud formation, and precipitation enhancement. An important factor in all of these problems is the calculation of the plume trajectory, which is often complicated by the presence of multiple sources and water phase changes in the plume. The latent heat does not strongly influence plume rise if there is no cloud present at the top of the plume. A one dimensional plume and cloud growth model was developed to study these effects. In this paper, the predictions of the model are compared with observations of cooling tower plume rise at the John E. Amos, W. Va. fossil-fuel power plant

  6. Seismic Analysis of Intake Towers Considering Multiple-Support Excitation and Soil-Structure Interaction Effects

    National Research Council Canada - National Science Library

    Vidot, Aidcer

    2004-01-01

    .... The other effect examined is the soil-structure interaction. First, a direct approach based on a finite element model of the tower, bridge, and dam with the earthquake motion applied at the bedrock is used...

  7. KM3NeT tower data acquisition and data transport electronics

    Directory of Open Access Journals (Sweden)

    Nicolau C.A.

    2016-01-01

    Full Text Available In the framework of the KM3Net European project, the production stage of a large volume underwater neutrino telescope has started. The forthcoming installation includes 8 towers and 24 strings, that will be installed 100 km off-shore Capo Passero (Italy at 3500 m depth. The KM3NeT tower, whose layout is strongly based on the NEMO Phase-2 prototype tower deployed in March 2013, has been re-engineered and partially re-designed in order to optimize production costs, power consumption, and usability. This contribution gives a description of the main electronics, including front-end, data transport and clock distribution system, of the KM3NeT tower detection unit.

  8. NACP MCI: Tower Atmospheric CO2 Concentrations, Upper Midwest Region, USA, 2007-2009

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set provides high precision and high accuracy atmospheric CO2 data from seven instrumented communication towers located in the U.S. Upper Midwest. The...

  9. NACP MCI: CO2 Flux Tower Measurements, Upper Midwest Region, USA, 2007-2009

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set provides high precision and high accuracy atmospheric CO2 data from seven instrumented communication towers located in the U.S. Upper...

  10. The study on the evaporation cooling efficiency and effectiveness of cooling tower of film type

    International Nuclear Information System (INIS)

    Li Yingjian; You Xinkui; Qiu Qi; Li Jiezhi

    2011-01-01

    Based on heat and mass transport mechanism of film type cooling, which was combined with an on-site test on counter flow film type cooling tower, a mathematical model on the evaporation and cooling efficiency and effectiveness has been developed. Under typical climatic conditions, air conditioning load and the operating condition, the mass and heat balances have been calculated for the air and the cooling water including the volume of evaporative cooling water. Changing rule has been measured and calculated between coefficient of performance (COP) and chiller load. The influences of air and cooling water parameters on the evaporative cooling efficiency were analyzed in cooling tower restrained by latent heat evaporative cooling, and detailed derivation and computation revealed that both the evaporative cooling efficiency and effectiveness of cooling tower are the same characteristics parameters of the thermal performance of a cooling tower under identical assumptions.

  11. The continuous tower of scalar fields as a system of interacting dark matter–dark energy

    International Nuclear Information System (INIS)

    Santos, Paulo

    2015-01-01

    This paper aims to introduce a new parameterisation for the coupling Q in interacting dark matter and dark energy models by connecting said models with the Continuous Tower of Scalar Fields model. Based upon the existence of a dark matter and a dark energy sectors in the Continuous Tower of Scalar Fields, a simplification is considered for the evolution of a single scalar field from the tower, validated in this paper. This allows for the results obtained with the Continuous Tower of Scalar Fields model to match those of an interacting dark matter–dark energy system, considering that the energy transferred from one fluid to the other is given by the energy of the scalar fields that start oscillating at a given time, rather than considering that the energy transference depends on properties of the whole fluids that are interacting.

  12. BOREAS TF-10 NSA-YJP Tower Flux, Meteorological, and Porometry Data

    Data.gov (United States)

    National Aeronautics and Space Administration — The flux and ancillary data collected at the NSA-YJP tower flux site by the TF-10 group. Measurements of stomatal conductance collected at the NSA-YJP site by the...

  13. LBA-ECO CD-04 Dendrometry, km 83 Tower Site, Tapajos National Forest, Brazil

    Data.gov (United States)

    National Aeronautics and Space Administration — A dendrometry study was conducted at the logged forest tower site, km 83 site, Tapajos National Forest, Para, Brazil over a period of 4 years following the...

  14. Pre-ABoVE: Arctic Vegetation Plots in Flux Tower Footprints, North Slope Alaska, 2014

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set provides vegetation, environmental, and soil data collected from plots located in the footprints of eddy covariance flux towers along a 300 km...

  15. Legionnaires' Disease Outbreaks and Cooling Towers, New York City, New York, USA.

    Science.gov (United States)

    Fitzhenry, Robert; Weiss, Don; Cimini, Dan; Balter, Sharon; Boyd, Christopher; Alleyne, Lisa; Stewart, Renee; McIntosh, Natasha; Econome, Andrea; Lin, Ying; Rubinstein, Inessa; Passaretti, Teresa; Kidney, Anna; Lapierre, Pascal; Kass, Daniel; Varma, Jay K

    2017-11-01

    The incidence of Legionnaires' disease in the United States has been increasing since 2000. Outbreaks and clusters are associated with decorative, recreational, domestic, and industrial water systems, with the largest outbreaks being caused by cooling towers. Since 2006, 6 community-associated Legionnaires' disease outbreaks have occurred in New York City, resulting in 213 cases and 18 deaths. Three outbreaks occurred in 2015, including the largest on record (138 cases). Three outbreaks were linked to cooling towers by molecular comparison of human and environmental Legionella isolates, and the sources for the other 3 outbreaks were undetermined. The evolution of investigation methods and lessons learned from these outbreaks prompted enactment of a new comprehensive law governing the operation and maintenance of New York City cooling towers. Ongoing surveillance and program evaluation will determine if enforcement of the new cooling tower law reduces Legionnaires' disease incidence in New York City.

  16. Trends, Opportunities, and Challenges for Tall Wind Turbine and Tower Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Lantz, Eric; Roberts, Owen; Dykes, Katherine

    2017-06-28

    This presentation summarizes recent analysis focused on characterizing the opportunity for Tall Wind technologies generally and for tall tower technologies specifically. It seeks to illuminate and explain the concept of Tall Wind, its impact on the wind industry to date, and the potential value of Tall Wind in the future. It also explores the conditions and locations under which the impacts of Tall Wind offer the most significant potential to increase wind technology performance. In addition, it seeks to examine the status of tall tower technology as a key sub-component of Tall Wind, focusing on the potential for continued innovation in tubular steel wind turbine towers and the status and potential for a select set of alternative tall tower technologies.

  17. BOREAS Follow-On HMet-03 Hourly Meteorological Data at Flux Towers, 1994-1996

    Data.gov (United States)

    National Aeronautics and Space Administration — Point data developed from in situ observations at four flux tower sites were combined to produce continuous, above the canopy, meteorological forcing data sets....

  18. BOREAS Follow-On HMet-03 Hourly Meteorological Data at Flux Towers, 1994-1996

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: Point data developed from in situ observations at four flux tower sites were combined to produce continuous, above the canopy, meteorological forcing data...

  19. BOREAS Follow-On FLX-04 Tower Flux and Meteorological Data from NSA Burn Site

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: Tower flux and meteorological data were collected above 4 black spruce forest sites in the NSA that experienced stand-replacing wildfires in 1989,1981,1964...

  20. Operating experience with cooling towers in French nuclear power stations: hydrobiology - aquatic chemistry

    International Nuclear Information System (INIS)

    Aprosi, G.; Bidard, F.; Nepveu de Villemarceau, C.

    1986-01-01

    This paper summarizes the difficulties encountered because of biological contaminants polluting the cooling towers of nuclear power stations. Then one describes the measures planned to reduce these phenomena [fr

  1. LBA-ECO CD-10 Temperature Profiles at km 67 Tower Site, Tapajos National Forest

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains a single text file which reports temperature measurements at the Para Western (Santarem) - km 67, Primary Forest Tower Site. This site is in...

  2. LBA-ECO CD-10 Temperature Profiles at km 67 Tower Site, Tapajos National Forest

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set contains a single text file which reports temperature measurements at the Para Western (Santarem) - km 67, Primary Forest Tower Site. This...

  3. NACP Site: Tower Meteorology, Flux Observations with Uncertainty, and Ancillary Data

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set contains meteorological, carbon cycle flux, phenology, and ancillary data measured at 47 eddy covariance flux tower sites across North...

  4. LBA-ECO CD-04 CO2 Profiles, km 83 Tower Site, Tapajos National Forest

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: Atmospheric carbon dioxide profiles were measured at 12 levels up to 64 m at the km 83 logged tower site in Tapajos National Forest, Santarem, Para,...

  5. LBA-ECO CD-04 CO2 Profiles, km 83 Tower Site, Tapajos National Forest

    Data.gov (United States)

    National Aeronautics and Space Administration — Atmospheric carbon dioxide profiles were measured at 12 levels up to 64 m at the km 83 logged tower site in Tapajos National Forest, Santarem, Para, Brazil. Data...

  6. LBA-ECO CD-04 Meteorological and Flux Data, km 83 Tower Site, Tapajos National Forest

    Data.gov (United States)

    National Aeronautics and Space Administration — Tower flux measurements of carbon dioxide,water vapor, heat, and meteorological variables were obtained at the Tapajos National Forest, km 83 site, Santarem, Para,...

  7. LBA-ECO CD-04 Soil Respiration, km 83 Tower Site, Tapajos National Forest, Brazil

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set reports on the flux of carbon dioxide from logged forest soils near the eddy flux tower at the km 83 site, Para, Brazil. The automated soil respiration...

  8. LBA-ECO CD-04 Soil Respiration, km 83 Tower Site, Tapajos National Forest, Brazil

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set reports on the flux of carbon dioxide from logged forest soils near the eddy flux tower at the km 83 site, Para, Brazil. The automated soil...

  9. Tokyo Tower and Tokyo Skytree: History and Symbolism in Contemporary Japan

    Directory of Open Access Journals (Sweden)

    Yunuen Ysela Mandujano-Salazar

    2016-12-01

    Full Text Available The Tokyo Tower and the Tokyo Skytree are the two most recognizable landmarks on the skyline of Japan’s capital. By means of a documental revision, a textual interpretative analysis of media contents, participant observation and unstructured interviews, the objective of this article is to identify the development of these towers as symbols of Tokyo and Japan. It is found that, with more than half a century of existence, the Tokyo Tower represents the successful post-war Japanese society, while in just five years the Tokyo Skytree has become a symbol of Japanese national spirit and resilience in an era of multiple crises. Both broadcasting towers are regularly portrayed in Japanese media linked to narratives of romance, dreams, family and community. Also, enhanced by their special lightening at night, they stand as attractive backgrounds for locals and visitors in relevant events in their lives.

  10. LBA-ECO CD-04 Meteorological and Flux Data, km 83 Tower Site, Tapajos National Forest

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: Tower flux measurements of carbon dioxide,water vapor, heat, and meteorological variables were obtained at the Tapajos National Forest, km 83 site,...

  11. NACP Site: Tower Meteorology, Flux Observations with Uncertainty, and Ancillary Data

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains meteorological, carbon cycle flux, phenology, and ancillary data measured at 47 eddy covariance flux tower sites across North America. The...

  12. LBA-ECO CD-04 Dendrometry, km 83 Tower Site, Tapajos National Forest, Brazil

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: A dendrometry study was conducted at the logged forest tower site, km 83 site, Tapajos National Forest, Para, Brazil over a period of 4 years following the...

  13. How tall can gelatin towers be? An introduction to elasticity and buckling

    Science.gov (United States)

    Taberlet, Nicolas; Ferrand, Jérémy; Camus, Élise; Lachaud, Léa; Plihon, Nicolas

    2017-12-01

    The stability of elastic towers is studied through simple hands-on experiments. Using gelatin-based stackable bricks, one can investigate the maximum height a simple structure can reach before collapsing. We show through experiments and by using the classical linear elastic theory that the main limitation to the height of such towers is the buckling of the elastic structures under their own weight. Moreover, the design and architecture of the towers can be optimized to greatly improve their resistance to self-buckling. To this aim, the maximum height of hollow and tapered towers is investigated. The experimental and theoretical developments presented in this paper can help students grasp the fundamental concepts in elasticity and mechanical stability.

  14. LBA-ECO CD-04 Leaf Area Index, km 83 Tower Site, Tapajos National Forest, Brazil

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: Leaf area index was estimated in an 18 ha plot at the logged forest tower site, km 83, Tapajos National Forest, Para, Brazil. The plot was adjacent to the...

  15. LBA-ECO CD-04 Leaf Area Index, km 83 Tower Site, Tapajos National Forest, Brazil

    Data.gov (United States)

    National Aeronautics and Space Administration — Leaf area index was estimated in an 18 ha plot at the logged forest tower site, km 83, Tapajos National Forest, Para, Brazil. The plot was adjacent to the eddy flux...

  16. Stochastic Analysis of the Influence of Tower Shadow on Fatigue Life of Wind Turbine Blade

    DEFF Research Database (Denmark)

    Pedersen, Ronnie; Nielsen, Søren R.K.; Thoft-Christensen, Palle

    2012-01-01

    Fatigue damage accumulation in upwind turbine blades is primarily influenced by turbulence in the inflow. However, the stress reversals during blade passages through the stagnating and deflected mean wind field in front of the tower also contributes significantly. In the paper the lower order...... statistical moments of the fatigue life of a blade are estimated and compared for a turbine with a tripod tower and a standard mono-tower, respectively. The stagnation zones for each of the legs of the tripod are narrower than for the mono-tower, and hence the stress reversals will be comparable smaller....... The blade stresses are calculated from a dynamic mechanical model based on a two dynamic degree of freedom with quasi-static correction for higher modes. The self-induced aero-elastic loading and the turbulence loading are modeled by means of a quasi-static model linearized around the operational point...

  17. On synthesis and optimization of cooling water systems with multiple cooling towers

    CSIR Research Space (South Africa)

    Gololo, KV

    2011-01-01

    Full Text Available Cooling water systems are generally designed with a set of heat exchangers arranged in parallel. This arrangement results in higher cooling water flow rate and low cooling water return temperature, thus reducing cooling tower efficiency. Previous...

  18. NACP VPRM NEE Parameters Optimized to North American Flux Tower Sites, 2000-2006

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set provides Vegetation Photosynthesis Respiration Model (VPRM) net ecosystem exchange (NEE) parameter values optimized to 65 flux tower sites across North...

  19. BOREAS Follow-On FLX-01 NSA-OBS Tower Flux, Meteorological, and Soil Temp. Data

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: The BOREAS Follow-On FLX-01 team collected tower flux, surface meteorological, and soil temperature data at the BOREAS NSA-OBS site continuously from March...

  20. MODELLING AND ANALYSIS OF TOWER INTERVENTION EQUIPMENT OF OIL & GAS WELLS

    Directory of Open Access Journals (Sweden)

    César A. Chagoyén-Méndez

    2015-04-01

    Full Text Available In this paper, the modeling and analysis of one tower Workover Rig belonging to a maintenance facility for oil and gas wells is presented. When performing the maintenance of this tower, it is detected that one of the elements of the structure has some deformation. It was decided not to put it into operation and submit it to research. The modeling of invariants as well as ways of modeling soil structure interaction is discussed. It was necessary to determine the material properties with the performing of test of some samples taken on two components of the tower. The structural behavior of the tower to operating loads are then studied, proving that the effect of the deformed element in the structure is not significant for the stresses to which are subject.

  1. LBA-ECO CD-04 LAI Estimated from Photos, km 83 Tower Site, Tapajos National Forest

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains summary data for monthly leaf area index (LAI) and plant area index (PAI) at the km 83 Tower Site, in the Tapajos National Forest, Para,...

  2. Modelling and control of a continuous distillation tower through fuzzy techniques

    OpenAIRE

    BARCELÓ RICO, FÁTIMA; Gozálvez Zafrilla, José Marcial; Diez Ruano, José Luís; Santafé Moros, María Asunción

    2011-01-01

    This paper presents a methodology for the design of a fuzzy controller applicable to continuous processes based on local fuzzy models and velocity linearizations. It has been applied to the implementation of a fuzzy controller for a continuous distillation tower. Continuous distillation towers can be subjected to variations in feed characteristics that cause loss of product quality or excessive energy consumption. Therefore, the use of a fuzzy controller is interesting to control process perf...

  3. Tall Tower Wind Energy Monitoring and Numerical Model Validation in Northern Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Koracin, D. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Kaplan, M. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Smith, C. [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, G. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Wolf, A. [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCord, T. [Desert Research Inst. (DRI), Las Vegas, NV (United States); King, K. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Belu, R. [Drexel Univ., Philadelphia, PA (United States); Horvath, K. [Croatian Meteorological and Hydrological Service, Zagreb (Croatia)

    2015-10-01

    The main objectives of this project were to conduct a tall-tower and sodar field campaign in complex terrain, investigate wind properties relevant to wind energy assessment, and evaluate high-resolution models with fixed and adaptive grid structures. Two 60-m towers at Virginia Peak ridges near Washoe Valley, Nevada, were instrumented with cup and vane anemometers as well as sonic anemometers, and an acoustic sounder (hereafter sodar) was installed near one of the towers. The towers were located 2,700 m apart with a vertical distance of 140 m elevation between their bases. Each tower had a downhill exposure of rolling complex terrain, with the nearby valley floor 3,200 m to the west and 800 m below the summit. Cup anemometers were installed at both towers at 20, 40, and 60 m, wind vanes at 20 and 60 m, and sonic anemometers at 20 and 60 m. The sodar measurements were nominally provided every 10 m in vertical distance from 40 to 200 m with the quality of the data generally decreasing with height. Surface air temperature, atmospheric pressure, and radiation measurements were conducted at 1.5 m AGL at both of the towers. Although the plan was to conduct a 1-year period of data collection, we extended the period (October 5, 2012 through February 24, 2014) to cover for possible data loss from instrument or communication problems. We also present a preliminary analysis of the towers and sodar data, including a detailed inventory of available and missing data as well as outliers. The analysis additionally includes calculation of the Weibull parameters, turbulence intensity, and initial computation of wind power density at various heights.

  4. Hydroaerothermal investigations conducted in the USSR to justify the construction of large cooling towers

    International Nuclear Information System (INIS)

    Goncharov, V.V.

    1989-01-01

    The multi-purpose task of improving water cooling systems of thermal and nuclear power plants is aimed at the development of efficient designs of cooling towers and other types of industrial coolers which call for comprehensive scientific justification. Cooling towers of 60-70 thou m 3 /h capacity with a chimney height of 130 m and those of 80-100 thou m 3 /h capacity with a chimney height of 150 m were developed. For circulating water systems of large power plants the design of a counterflow chimney cooling tower of 180 thou m 3 /h capacity has been recently developed. At present the work is being conducted on developing a new three-cell cooling tower featuring high reliability, operational flexibility and cost-effectiveness of the design. This cooling tower, besides having higher operating reliability than the conventional one of circular shape, can ensure the commissioning, current repairs and overhauls of water cooling arrangements in a cell-wise sequence, i.e. without shutting down the power generating units. Laboratory and field investigations of the spray-type cooling towers having no packing (fill), studies on heat and mass exchanges processes, aerodynamics of droplet flows and new designs of sprayers made it possible to come to a conclusion that their cooling capacity can be substantially increased and brought up to the level of the cooling towers with film packings. The pilot cooling towers were designed according to the counterflow, crossflow and cross-counterflow schemes. The basic investigation method remains to be the experimental one. On the test rigs and aerodynamic models the heat and mass transfer and aerodynamic resistance coefficients are determined. These studies and subsequent calculations are based on the heat balance equation

  5. Decline of Medieval Urban Symbols of Power: Tower Houses in Trogir, Croatia

    Directory of Open Access Journals (Sweden)

    Plosnić Škarić, Ana

    2017-08-01

    Full Text Available The paper analyses the diminishment of the importance and significance of the medieval tower houses in Trogir caused by social, political, and economic changes as well as by the urban development and the changes in the city defence system. The findings suggest that the decline of the towers had already begun during the 13th century. Eventually it resulted in the preservation of only a few, who have, however, been subjected to subsequent remodelling.

  6. On the optimum performance of forced draft counter flow cooling towers

    International Nuclear Information System (INIS)

    Soeylemez, M.S.

    2004-01-01

    A thermo-hydraulic performance optimization analysis is presented, yielding simple algebraic formula for estimating the optimum performance point of counter current mechanical draft wet cooling towers. The effectiveness-Ntu method is used in the present study, together with the derivation of psychometric properties of moist air based on a numerical approximation method, for thermal performance analysis of wet cooling towers of the counter flow type

  7. Vertical sampling flights in support of the 1981 ASCOT cooling tower experiments: field effort and data

    Energy Technology Data Exchange (ETDEWEB)

    Gay, G.T.

    1982-03-01

    During the month of August 1981, three nights of experimental sampling of tracers released into the cooling tower plume of a geothermal power plant were conducted. In these experiments a tethered balloon was used to lift a payload so as to obtain vertical profiles of the cooling tower plume and the entrained tracers. A description of the equipment used, the field effort and the data acquired are presented here.

  8. An integrated system for the energy production and accumulation from renewable sources: a rural tower prototype

    Science.gov (United States)

    Di Francesco, Silvia; Petrozzi, Alessandro; Montesarchio, Valeria

    2014-05-01

    This research work presents the implementation of an architectural prototype aiming at the complete energy self-sufficiency through an integrated system based on renewable energy. It is suitable for historical buildings in rural areas, isolated but important from natural and architectonical point of view. In addition to the energy aspects, it is important to protect the impact in terms of land-use and environment. This idea is also especially powerful because in the rural countries there are many little building centers abandoned because they are devoid of a connection to the electric energy grid and methane piping. Thus, taking inspiration from dove towers, architectural typology widespread in central Italy, a virtual model has been developed as an integrated system for renewable energy production, storage and supply. While recovering the ancient tower, it is possible to design and assembly an integrated intelligent system, able to combine energy supply and demand: a new tower that should be flexible, efficient and replicable in other contexts as manufacturing, commercial and residential ones. The prototype has been applied to a real case of study, an ancient complex located in Umbria Region. The sources for electric production installed on the tower are photovoltaics, on the head and shaft of the tower, hydropower and a biomass gasifier providing thermal too. A tank at the head of the tower allows an available hydraulic potential energy, for the turbine at any time, to cover photovoltaic lacks, caused by sudden loss of production, for environmental causes. Conversely, photovoltaic peaks, otherwise unusable, can be used to reload the water from the receiving tank at the foot of the tower, up to the tank in the head. The same underground tank acts as a thermal flywheel to optimize the geothermal heat pumps for the heat and cold production. Keywords: hydropower, photovoltaics, dove tower.

  9. Modeling of hydronic radiant cooling of a thermally homeostatic building using a parametric cooling tower

    International Nuclear Information System (INIS)

    Ma, Peizheng; Wang, Lin-Shu; Guo, Nianhua

    2014-01-01

    Highlights: • Investigated cooling of thermally homeostatic buildings in 7 U.S. cities by modeling. • Natural energy is harnessed by cooling tower to extract heat for building cooling. • Systematically studied possibility and conditions of using cooling tower in buildings. • Diurnal ambient temperature amplitude is taken into account in cooling tower cooling. • Homeostatic building cooling is possible in locations with large ambient T amplitude. - Abstract: A case is made that while it is important to mitigate dissipative losses associated with heat dissipation and mechanical/electrical resistance for engineering efficiency gain, the “architect” of energy efficiency is the conception of best heat extraction frameworks—which determine the realm of possible efficiency. This precept is applied to building energy efficiency here. Following a proposed process assumption-based design method, which was used for determining the required thermal qualities of building thermal autonomy, this paper continues this line of investigation and applies heat extraction approach investigating the extent of building partial homeostasis and the possibility of full homeostasis by using cooling tower in one summer in seven selected U.S. cities. Cooling tower heat extraction is applied parametrically to hydronically activated radiant-surfaces model-buildings. Instead of sizing equipment as a function of design peak hourly temperature as it is done in heat balance design-approach of selecting HVAC equipment, it is shown that the conditions of using cooling tower depend on both “design-peak” daily-mean temperature and the distribution of diurnal range in hourly temperature (i.e., diurnal temperature amplitude). Our study indicates that homeostatic building with natural cooling (by cooling tower alone) is possible only in locations of special meso-scale climatic condition such as Sacramento, CA. In other locations the use of cooling tower alone can only achieve homeostasis

  10. The measurement of absorbed Charpy impact energy using a vertical drop tower

    Science.gov (United States)

    Server, W. L.; Henderson, G. R.

    1981-05-01

    Standard Charpy calibration specimens designed for verification of pendulum impact machines have been tested on a vertical drop tower impact machine. Two different test techniques (optical velocity measurement and integrated digital load-time response) for measuring the fracture energy of these specimens have produced equivalent sets of data which match the range of expected pendulum machine results. The more flexible vertical drop tower machine can therefore be used to measure Charpy impact energies with the same reliability as the conventional pendulum machines.

  11. Surface and Tower Meteorological Instrumentation at Barrow (METTWR4H) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Ritsche, MT

    2008-04-01

    The Barrow meteorology station (BMET) uses mainly conventional in situ sensors mounted at four different heights (2m, 10m, 20m and 40m) on a 40 m tower to obtain profiles of wind speed, wind direction, air temperature, dew point and humidity. It also obtains barometric pressure, visibility and precipitation data from sensors at the base of the tower. Additionally, a Chilled Mirror Hygrometer and an Ultrasonic wind speed sensor are located near the 2m level for comparison purposes.

  12. Design of Tall Prestressed Reinforced Concrete Towers Based on Design Spectrum and Time History Analysis

    OpenAIRE

    Scurtu, Ioan-Cosmin; Muşat, Vasile

    2013-01-01

    In this paper a case study for tall reinforced concrete tower design is presented. The aim of this study is to develop a design method for concrete reinforced towers used to support wind power turbines, taking into account the particular design requirements related to the Romania specific soil conditions and earthquake hazard. A spectral analysis was done using current design practice, and starting from these benchmark values, a more thorough time-history analysis was done with the a detaile...

  13. Study of the comparative costs of five wet/dry cooling tower concepts

    Energy Technology Data Exchange (ETDEWEB)

    Zaloudek, F.R.; Allemann, R.T.; Faletti, D.W.; Johnson, B.M.; Parry, H.L.; Smith, G.C.; Tokarz, R.D.; Walter, R.A.

    1976-09-01

    The projected cost of five alternative dry/wet power plant heat rejection concepts was studied under conditions imposed by hypothetical use in association with the San Juan Plant Unit 3, a 550-MWe facility currently under construction near the ''Four Corners'' area of New Mexico. The five alternative concepts were: integrated dry/wet tower; separate dry and wet towers; metal fin-tube induced draft tower with deluge water augmentation; plastic heat exchanger tower with deluge water augmentation, and metal fin-tube/deluge augmentation tower with an intermediate ammonia evaporation-condensation condenser and the cooling tower. The integrated dry/wet tower concept, already chosen for service at San Juan Unit 3, was included for reference purposes. All concepts were conceptually designed and estimated using the same bases and employing uniform practices. Each concept was assumed to use all water allocated for consumptive use in Unit 3. The cost estimates obtained showed the following descending order of ''comparable capital cost'': separate dry/wet; metal fin-tube/deluge; integrated dry/wet; plastic tube/deluge; and metal fin-tube/deluge/ammonia. The results indicate that two of the advanced concepts considered, i.e., the plastic tube/deluge concept and the metal fin tube/deluge/ammonia concept, can possibly reduce the overall costs of dry/wet cooling under conditions imposed by the site considered. It was recommended that these two concepts receive additional attention by the ERDA Dry Cooling Tower Program and industry to further quantify their potential benefits and demonstrate their performance and reliability.

  14. Determination of fan flow and water rate adjustment for off-design cooling tower tests

    International Nuclear Information System (INIS)

    Vance, J.M.

    1984-02-01

    The determination of the performance of a mechanical draft cooling tower requires that the air mass flow through the tower be known. Since this flow is not measured, it has been customary to use the manufacturer's design air flow and adjust it by the one-third power of the ratio of the design to test fan horsepower. The most nearly correct approximation of air flow through a tower can be obtained by incrementally moving through the tower from air inlet to outlet while calculating mass flows, energy balances, and pressure drops for each increment and then utilizing fan curves to determine volumetric and mass flows. This procedure would account for changes in air humidity and density through the tower, evaporation of water, effect of water rate on air pressure drop, and changes in fan characteristics. These type calculations may be within the capabilities of all in the near future, but for the interim, it is recommended that a more elementary approach be used which can be handled with a good calculator and without any proprietary data. This approach depends on certain assumptions which are acceptable if the tower test is conducted within CTI code requirements. The fan must be considered a constant suction volume blower for a given blade pitch. The total pressure at the fan, a function of volumetric flow and wet air density, must be assumed to be unaffected by other considerations, and the fan horsepower must be assumed to change only as volumetric flow and wet air density changes. Given these assumptions, along with design information normally provided with a tower, the determination of air flow through a tower in a test can be made from CTI test data. The air flow, and consequently the water rate adjustment and corrected water to air ratio, are derived and found to be direct functions of horsepower and density and an inverse function of wet air humidities

  15. Final Environmental Assessment: Construction of an Evapotranspiration Tower, Arnold Air Force Base, Tennessee

    Science.gov (United States)

    2004-07-01

    Ecosystem management also helps ATUP:\\ARNOLDAFB\\3153310034\\EVAPOTRANS TOWER\\FINAL ET TOWER EA.DOC 1·3 maintain nahual landscapes for military...Contacts and Correspondence Richard McWhite, Civ AEDC/SED Rick Alvey, Aerospace Testing Alliance Nahual Resources Steve Farrington, Aerospace Testing...Alliance Natural Resources Kevin Fitch, Aerospace Testing Alliance Nahual Resources Mark Moran, Aerospace Testing Alliance Natural Resources Ed

  16. Bottom Backscattering Strengths Measured in Shallow and Deep Water

    Science.gov (United States)

    2017-01-18

    to the MF results. 18-01-2017 Memorandum Report Bottom scattering Bottom scattering strength Reverberation Underwater acoustics Active sonar August...Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/7160--17-9701 Bottom Backscattering Strengths Measured in Shallow and Deep Water January...18, 2017 Approved for public release; distribution is unlimited. RogeR C. gauss edwaRd L. Kunz Joseph M. FiaLKowsKi RiChaRd Menis Acoustic Signal

  17. Bottom-up grammar analysis : a functional formulation

    OpenAIRE

    Jeuring, J.T.; Swierstra, D.

    1994-01-01

    This paper discusses bottom-up grammar analysis problems such as te EMPTY problem and the FIRST problem. It defines a general class of bottom-up grammar analysis problems, and from this definition it derives a functional program for performing bottom-up grammar analysis. The derivation is purely calculational, using theorems from lattice therory, the Bird-Meertens calculus, and laws for list-comprehensions. Sufficient conditions guaranteeing the existence of a solution emerge as a byproduct o...

  18. 49 CFR 179.220-18 - Bottom outlets.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Bottom outlets. 179.220-18 Section 179.220-18... Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.220-18 Bottom outlets. (a) The inner container may be equipped with a bottom outlet of approved design and an opening provided in the...

  19. Performance Analysis of an Updraft Tower System for Dry Cooling in Large-Scale Power Plants

    Directory of Open Access Journals (Sweden)

    Haotian Liu

    2017-11-01

    Full Text Available An updraft tower cooling system is assessed for elimination of water use associated with power plant heat rejection. Heat rejected from the power plant condenser is used to warm the air at the base of an updraft tower; buoyancy-driven air flows through a recuperative turbine inside the tower. The secondary loop, which couples the power plant condenser to a heat exchanger at the tower base, can be configured either as a constant-pressure pump cycle or a vapor compression cycle. The novel use of a compressor can elevate the air temperature in the tower base to increases the turbine power recovery and decrease the power plant condensing temperature. The system feasibility is evaluated by comparing the net power needed to operate the system versus alternative dry cooling schemes. A thermodynamic model coupling all system components is developed for parametric studies and system performance evaluation. The model predicts that constant-pressure pump cycle consumes less power than using a compressor; the extra compression power required for temperature lift is much larger than the gain in turbine power output. The updraft tower system with a pumped secondary loop can allow dry cooling with less power plant efficiency penalty compared to air-cooled condensers.

  20. A tower structured scintillator-lead photon calorimeter using a novel fiber optics readout system

    International Nuclear Information System (INIS)

    Fessler, H.; Freund, P.; Gebauer, J.; Glas, K.M.; Pretzl, K.P.; Seyboth, P.; Seyerlein, J.; Thevenin, J.C.

    1984-06-01

    Described is the construction and the performance of a tower structured scintillator-lead photon calorimeter using a novel fiber optics readout system. The calorimeter is divided into 9 individual towers. Each tower has a cross section of 5x5 cm 2 and consists of 60 layers of 2 mm lead plus 5 mm thick scintillator. The four sides of each tower are covered by thin acrylic sheets (1.5 mm thick) doped with a wavelength shifting material. The light produced in each scintillator plate is first converted in these sheets, then converted a second time in a set of polystyrene optical fibers (diameter 2 mm) which run longitudinally through the calorimeter along the corners of each tower. A small diameter photomultiplier was attached to the fibers at the back end of the calorimeter. The obtained energy resolution with incident electrons in the range of 0.25 - 5.0 GeV/c is sigma/E = 0.10/√E. The uniformity of response across the front face of each tower was measured. (orig.)

  1. Wind Turbine Tower Vibration Modeling and Monitoring by the Nonlinear State Estimation Technique (NSET

    Directory of Open Access Journals (Sweden)

    Peng Guo

    2012-12-01

    Full Text Available With appropriate vibration modeling and analysis the incipient failure of key components such as the tower, drive train and rotor of a large wind turbine can be detected. In this paper, the Nonlinear State Estimation Technique (NSET has been applied to model turbine tower vibration to good effect, providing an understanding of the tower vibration dynamic characteristics and the main factors influencing these. The developed tower vibration model comprises two different parts: a sub-model used for below rated wind speed; and another for above rated wind speed. Supervisory control and data acquisition system (SCADA data from a single wind turbine collected from March to April 2006 is used in the modeling. Model validation has been subsequently undertaken and is presented. This research has demonstrated the effectiveness of the NSET approach to tower vibration; in particular its conceptual simplicity, clear physical interpretation and high accuracy. The developed and validated tower vibration model was then used to successfully detect blade angle asymmetry that is a common fault that should be remedied promptly to improve turbine performance and limit fatigue damage. The work also shows that condition monitoring is improved significantly if the information from the vibration signals is complemented by analysis of other relevant SCADA data such as power performance, wind speed, and rotor loads.

  2. Experimental Investigation on Strengthening of Bolted Connections in Transmission/Communication Towers

    Science.gov (United States)

    Balagopal, R.; Prasad Rao, N.; Rokade, R. P.; Umesha, P. K.

    2018-02-01

    Due to increase in demand for power supply and increase in bandwidth for communication industry, the existing transmission line (TL) and communication towers needs to be strengthened. The strengthening of existing tower is economical rather than installation of new towers due to constraints in acquisition of land. The size of conductors have to be increased or additional number of antenna needs to be installed in existing TL/communication tower respectively. The compression and tension capacity of members in the existing towers have to be increased to sustain the additional loads due to wind and self-weight of these components. The tension capacity enhancement of existing angle sections in live line condition without power shut-down is a challenging task. In the present study, the use of Glass Fiber Reinforced Plastic (GFRP) plate/angle sections is explored to strengthen existing bolted connections in TL/communication towers. Experimental investigation conducted at component level on strengthening of existing two types of single cover steel butt joint, one made of steel plate and another joint made of steel angle sections respectively. First series of experiment conducted on strengthening the connection using GFRP plate/cleat angle sections. The second series of strengthening experiment is conducted using steel plate/angle sections to replace GFRP sections. The load sharing behaviour of strengthened GFRP and steel section is compared and suitable recommendations are given.

  3. Seismic Response of Long-Span Triple-Tower Suspension Bridge under Random Ground Motion

    Directory of Open Access Journals (Sweden)

    Chang-ke Jiao

    2017-01-01

    Full Text Available Multitower suspension bridge is of different style compared to the traditional suspension bridge with two towers, and consequently the dissimilarity of static and dynamic behaviors is distinct. As a special case of multitower suspension bridge, two long-span triple-tower suspension bridges have been constructed in China and the seismic random response of triple-tower suspension bridges is studied in this paper. A nonlinear dynamic analysis finite element model is established in ABAQUS and the Python language is utilized to facilitate the preprocess and postprocess during the finite element analysis. The procedure for random response calculation of structures based on the pseudoexcitation method is presented, with the initial equilibrium state of structure considered, which may be ignored for long-span bridges during calculating of stochastic response. The stationary seismic random responses of triple-tower suspension bridge under uniform excitation in firm, medium, and soft soil conditions and under spatially varying excitation in soft soil are investigated. The distribution of RMS of random responses of displacements and internal forces of the stiffening girder and towers is presented and discussed in detail. Results show that spatially variable ground motions should be considered in the stochastic analysis of triple-tower suspension bridge.

  4. A tower structured scintillator-lead photon calorimeter using a novel fiber optics readout system

    Science.gov (United States)

    Fessler, H.; Freund, P.; Gebauer, J.; Glas, J. M.; Pretzl, K. P.; Seyboth, P.; Seyerlein, J.; Thevenin, J. C.

    1985-01-01

    Described is the construction and the performance of a tower-structured scintillator-lead photon calorimeter using a novel fiber optics readout system. The calorimeter is divided into 9 individual towers. Each tower has a cross section of 5 × 5 cm 2 and consists of 60 layers of 2 mm lead plus 5 mm thick scintillator. The four sides of each tower are covered by thin acrylic sheets (1.5 mm thick) doped with a wavelength shifting material. The light produced in each scintillator plate is first converted in these sheets, then converted a second time in a set of polystyrene optical fibers (diameter 2 mm) which run longitudinally through the calorimeter along the corners of each tower. A small diameter photomultiplier was attached to the fibers at the back end of the calorimeter. The obtained energy resolution with incident electrons in the range of 0.25-5.0 {GeV}/{c} is {σ}/{E} = {0.10}/{√E}. The uniformity of response across the front face of each tower was measured.

  5. A Tower Model for Lightning Overvoltage Studies Based on the Result of an FDTD Simulation

    Science.gov (United States)

    Noda, Taku

    This paper describes a method for deriving a transmission tower model for EMTP lightning overvoltage studies from a numerical electromagnetic simulation result obtained by the FDTD (Finite Difference Time Domain) method. The FDTD simulation carried out in this paper takes into account the following items which have been ignored or over-simplified in previously-presented simulations: (i) resistivity of the ground soil; (ii) arms, major slant elements, and foundations of the tower; (iii) development speed of the lightning return stroke. For validation purpose a pulse test of a 500-kV transmission tower is simulated, and a comparison with the measured result shows that the present FDTD simulation gives a sufficiently accurate result. Using this validated FDTD-based simulation method the insulator-string voltages of a tower for a lightning stroke are calculated, and based on the simulation result the parameter values of the proposed tower model for EMTP studies are determined in a systematic way. Since previously-presented models include trial-and-error process in the parameter determination, it can be said that the proposed model is more general in this regard. As an illustrative example, the 500-kV transmission tower mentioned above is modeled, and it is shown that the derived model closely reproduces the FDTD simulation result.

  6. Wind-induced transmission tower foundation loads. A field study-design code comparison

    Energy Technology Data Exchange (ETDEWEB)

    Savory, E. [Department of Mechanical and Materials Engineering, University of Western Ontario, London, Ont. (Canada); Parke, G.A.R.; Disney, P.; Toy, N. [School of Engineering, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2008-06-15

    This paper presents a comparison between the wind-induced foundation loads measured on a type L6 transmission line tower during a field study in the UK and those computed using the UK Code of Practice for lattice tower and transmission line design (BS8100). In this work, the Code provisions have been generalised to give the wind-induced strain in each of the tower legs immediately above the foundation as a function of wind direction and wind speed at the top of the tower. The complete data set from the field monitoring has been decomposed to provide a similar formulation for comparison purposes. The analysis shows excellent agreement between the Code calculations and the measured results, within the overall accuracy of the field data. This indicates that, at least for the tower type examined here, the existing design Code provides a reliable transformation of the local wind speed at the top of the tower into tension and compression loads on the foundations. (author)

  7. A test of Newton's Law of Gravity using the BREN Tower, Nevada

    International Nuclear Information System (INIS)

    Kasameyer, P.; Thomas, J.; Fackler, O.; Mugge, M.; Kammeraad, J.; Millett, M.; Harris, B.; Felske, D.

    1989-01-01

    We predicted gravity values on a tower by upward continuing an extensive set of surface data in order to test the 1/r 2 dependence of Newton's Law of Universal Gravitation. We measured gravity at 12 heights up to 454 m on a tower at the Nevada Test Site, and at 91 locations on the surface of the earth within 2.5 kilometers of the tower. These data have been combined with 60,000 surface gravity measurements within 300 kilometers of the tower and have been used to predict the gravitational field on the tower via a solution of Laplace's equation. A discrepancy between the observed gravity values and the prediction could suggest a breakdown of Newtonian Gravity, but we observe none. Our preliminary results are consistent with the Newtonian hypothesis to within 93 +- 95 μgals at the top of the tower, a result which conflicts with the previously reported 500 μgal non-Newtonian signal seen at 562 meters above the earth. 24 refs., 2 figs

  8. Laboratory Experiment and Numerical Analysis of a New Type of Solar Tower Efficiently Generating a Thermal Updraft

    Directory of Open Access Journals (Sweden)

    Yuji Ohya

    2016-12-01

    Full Text Available A new type of solar tower was developed through laboratory experiments and numerical analyses. The solar tower mainly consists of three components. The transparent collector area is an aboveground glass roof, with increasing height toward the center. Attached to the center of the inside of the collector is a vertical tower within which a wind turbine is mounted at the lower entry to the tower. When solar radiation heats the ground through the glass roof, ascending warm air is guided to the center and into the tower. A solar tower that can generate electricity using a simple structure that enables easy and less costly maintenance has considerable advantages. However, conversion efficiency from sunshine energy to mechanical turbine energy is very low. Aiming to improve this efficiency, the research project developed a diffuser-type tower instead of a cylindrical tower, and investigated a suitable diffuser shape for practical use. After changing the tower height and diffuser open angle, with a temperature difference between the ambient air aloft and within the collector, various diffuser tower shapes were tested by laboratory experiments and numerical analyses. As a result, it was found that a diffuser tower with a semi-open angle of 4° is an optimal shape, producing the fastest updraft at each temperature difference in both the laboratory experiments and numerical analyses. The relationships between thermal updraft speed and temperature difference and/or tower height were confirmed. It was found that the thermal updraft velocity is proportional to the square root of the tower height and/or temperature difference.

  9. How Service Innovation Boosts Bottom Lines

    Directory of Open Access Journals (Sweden)

    Claude Legrand

    2013-09-01

    Full Text Available In the national quest for ground-breaking R&D discoveries and inventions, service innovation is frequently ignored at considerable cost to an organization’s bottom line and a nation’s productivity. For the fact is that innovation applied systematically to all activities outside of R&D can make the difference between uninspiring results and substantial growth in every sector. Many countries, in particular in Europe, have recognized the importance of service innovation and are devoting considerable resources to research, the capture of best practices, and the measurement of progress and success. Given the physiognomy of the modern economy, it does not make sense for leaders in the Canadian public sector to devote all available innovation investment dollars to science and technology R&D. This article explores why service innovation is not yet a priority on the innovation agenda in Canada and why we should correct the dangerous misconception that there is just one “innovation gap” that needs to be addressed. It provides practical recommendations that public and private sector leaders can use to take advantage of this under-valued, high-potential innovation opportunity and calls for the creation of a national service innovation resource to support enterprises of all sizes as a means to improve Canadian productivity.

  10. Brayton-Cycle Baseload Power Tower CSP System

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Bruce [Wilson Solarpower Corporation, Boston, MA (United States)

    2013-12-31

    The primary objectives of Phase 2 of this Project were:1. Engineer, fabricate, and conduct preliminary testing on a low-pressure, air-heating solar receiver capable of powering a microturbine system to produce 300kWe while the sun is shining while simultaneously storing enough energy thermally to power the system for up to 13 hours thereafter. 2. Cycle-test a high-temperature super alloy, Haynes HR214, to determine its efficacy for the system’s high-temperature heat exchanger. 3. Engineer the thermal energy storage system. This Phase 2 followed Wilson’s Phase 1, which primarily was an engineering feasibility study to determine a practical and innovative approach to a full Brayton-cycle system configuration that could meet DOE’s targets. Below is a summary table of the DOE targets with Wilson’s Phase 1 Project results. The results showed that a Brayton system with an innovative (low pressure) solar receiver with ~13 hours of dry (i.e., not phase change materials or molten salts but rather firebrick, stone, or ceramics) has the potential to meet or exceed DOE targets. Such systems would consist of pre-engineered, standardized, factory-produced modules to minimize on-site costs while driving down costs through mass production. System sizes most carefully analyzed were in the range of 300 kWe to 2 MWe. Such systems would also use off-the-shelf towers, blowers, piping, microturbine packages, and heliostats. Per DOE’s instructions, LCOEs are based on the elevation and DNI levels of Daggett, CA, for a 100 MWe power plant following 2 GWe of factory production of the various system components.

  11. Ozone deposition and stomatal uptake at flux tower sites

    Science.gov (United States)

    Ducker, J.; Holmes, C.; Schnell, J.; Fares, S.; Keenan, T. F.; Munger, W.; Mammarella, I.

    2017-12-01

    We develop and evaluate a method for estimating O3 deposition and stomatal O3 uptake at FLUXNET tower sites. The method combines standard micrometeorological measurements that are made with the eddy covariance method with a gridded dataset of surface O3 concentration. We evaluate the method at 3 sites where O3 fluxes were measured. This comparison shows that our method reproduces 69-92% of the variability with modest bias. The remaining unexplained variance is due to stomatal conductance filtering methods, non-stomatal parameterizations, representation error in the gridded O3 data and measurement error in . Using our O3 deposition method, we calculate the stomatal O3 uptake at 41 FLUXNET sites in the US and 55 FLUXNET sites in Europe. The spatial patterns in stomatal O3 uptake are driven by the gradients in humidity, which promote stomatal conductance rather than spatial patterns in O3 concentrations alone. Factors such as land cover, land management, and plant functional types are also important underlying factors in the spatial variability in the stomatal O3 uptake throughout the FLUXNET network. With the synthetic O3 flux data we examine the relationship with common concentration-based metrics for plant injuries due to O3, such as mean concentration, AOT40 and W126. We show that concentration-based metrics are poor predictors of O3 flux (R2 ≤ 0.11), when applied across different biomes, but if they must be used, they should be limited to cases where VPD < 1.5 kPa (R2 ≤ 0.28). The synthetic O3 flux data enable evaluation of atmospheric chemistry models at many additional sites.

  12. Reliability Assessment of Steel-Aluminium Lattice Tower

    Science.gov (United States)

    Dudzik, Agnieszka

    2017-10-01

    In the subject of the present study a probabilistic approach to the analysis of steelaluminium lattice tower was used. Structural design parameters are defined as the deterministic values and random variables. Random variables are not correlated. The criterion for structural failure is expressed the limits of functions referring to the serviceability limit state. The description of the limit state of structure implicit forms of the random variables function was used. The study presents a combination of the reliability analysis program with the MES3D external FEM program. The NUMPRESS software, created at the IFTR PAS, was used in the reliability analysis. The Hasofer-Lind reliability index, determined using an iterative procedure of Rackwitz-Fiessler, was used as a reliability measure. The values of reliability index for different cases of the vector of random variables, that is, different descriptions of mathematical model of the structure, were determined. The effect of assumed probability distribution of individual random variables on the value of the reliability index was determined. In the description of random variables, the different types of probability distribution were used and the values of the reliability index for the normal distribution and the distribution chosen according to the kind of a variable were compared. The primary research method is the FORM method. In order to verify the correctness of the calculation Monte Carlo and Importance Sampling methods are used. The relative error of the reliability index was calculated taking the simulation Monte Carlo method as a reference. The effectiveness of the primary research method was performed by comparing the number of calls of the limit state, which is connected with the calculation time. The sensitivity of reliability index to the random variables was defined.

  13. Acoustic Imaging Evaluation of Juvenile Salmonid Behavior in the Immediate Forebay of the Water Temperature Control Tower at Cougar Dam, 2010

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Fenton; Johnson, Gary E.; Royer, Ida M.; Phillips, Nathan RJ; Hughes, James S.; Fischer, Eric S.; Ploskey, Gene R.

    2011-10-01

    , average fish length remained relatively consistent (132 {+-} 39 mm), after which average lengths increased to 294 {+-} 145 mm for mid-November though early December. Fish behavior analysis indicates milling in front of the intake tower was the most common behavior observed throughout the study period (>50% of total fish events). The next most common movement patterns were fish traversing along the front of the tower, east-to-west and west-to-east. The proportion of fish events seen moving into (forebay to tower) or out of (tower to forebay) the tower was generally low throughout the spring, summer, and early fall for both directions combined. From mid-December 2010 through the end of the study, the combined proportions of fish moving into and out of the tower were higher than previous months of this study. Schooling behavior was most distinct in the spring from late April through mid-June. Schooling events were present in 30 - 96% of the fish events during that period, with a peak in mid-May. Schooling events were also present in the summer, but at lower numbers. Diel distributions for schooling fish during spring, fall, and winter months indicate schooling was concentrated during daylight hours. No schooling was observed at night. Predator activity was observed during late spring, when fish abundance and schooling were highest for the year, and again in the fall months when fish events increased from a summer low. No predator activity was observed in the summer, and little activity occurred during the winter months. For the two days of BlueView data analyzed for vertical distribution in the forebay, a majority of fish (>50%) were present in the middle of the water column (10 - 20 m deep). Between 20 and 41 % of total fish abundance were found in the bottom of the water column (20 - 30 m deep). Few fish were observed in the top 10 m of the water column.

  14. Heavy metal concentrations in Bottom Sediments of Ikpoba River ...

    African Journals Online (AJOL)

    MICHAEL HORSFALL

    2014-06-23

    Jun 23, 2014 ... March 2014. Vol. 18 (1) 27-32. Full-text Available Online at www.ajol.info and www.bioline.org.br/ja. Heavy metal concentrations in Bottom Sediments of Ikpoba River, Edo State, Nigeria. *1 ... Introduction: Bottom sediment is an integral part of the abiotic ... bank of this station includes bamboo trees, grasses.

  15. Use of Unprocessed Coal Bottom Ash as Partial Fine Aggregate ...

    African Journals Online (AJOL)

    2012r

    plastic density to decrease and bleeding to increase. Moreover, above 40% replacement of bottom ash, compressive strength, flexural strength, and modulus of elasticity decreased sharply. In addition, an increase in bottom ash content improved the drying shrinkage performance of the concrete. The research also.

  16. Fresh Bottom Ash Characteristics Dependence on Fractional Composition

    Directory of Open Access Journals (Sweden)

    Jurgita Seniūnaitė

    2017-09-01

    Full Text Available Waste incineration process generates two main by-products streams: fly ash and bottom ash. Bottom ash is composed of a variety of oxides, heavy metals and salts. Chemical materials distributed unevenly in different fractions of bottom ash. This study investigates the heavy metals (Pb, Cd content dependence of bottom ash and fraction composition. Studies were performed with five different fractions (0–2 mm; 2–5.6 mm; 5.6–11.2 mm; 11.2–22,4 mm; 22.4–40 mm of fresh bottom ash. After a one-step leaching test (distilled water was used as a solvent, was determinate, that highest concentrations of the lead (Pb (from 0.141 to 0.146 mg/l are leached from the smallest (0–2 mm 2–5.6 mm bottom ash fractions particles. Heavy metals concentration in these fractions eluates respectively was 2.83 and 2.91 times higher than the limit value of leaching. The highest concentration of cadmium (4.214 mg/l was determinate in 0–2 mm fraction bottom ash eluate. concentration of cadmium was 1.40 times higher than the limit value of leaching. It can be concluded that 0–2 mm; 2–5.6 mm fraction bottom ash can’t be used in civil engineering, without pre-treatment (eg. washing or aging.

  17. Postcolonial Appalachia: Bhabha, Bakhtin, and Diane Gilliam Fisher's "Kettle Bottom"

    Science.gov (United States)

    Stevenson, Sheryl

    2006-01-01

    Diane Gilliam Fisher's 2004 award-winning book of poems, "Kettle Bottom," offers students a revealing vantage point for seeing Appalachian regional culture in a postcolonial context. An artful and accessible poetic sequence that was selected as the 2005 summer reading for entering students at Smith College, "Kettle Bottom"…

  18. Monitoring of metals in Tilapia nilotica tissues, bottom sediments ...

    African Journals Online (AJOL)

    Tilapia (Tilapia nilotica), bottom sediments and water were collected from Nworie River and Oguta Lake. The muscle, liver and gills of the fish as well as the bottom sediments and water were analysed for Al, Cr, Cd, Pb, As, Zn, Mn, Co, Se, Cu, Ni and Fe using atomic absorption spectrophotometer to highlight the importance ...

  19. Ocean bottom pressure modeling for detection of seafloor vertical deformation

    Science.gov (United States)

    Inazu, D.; Hino, R.; Fujimoto, H.

    2009-12-01

    Detection of seafloor crustal deformation is a difficult problem in marine geodesy. Horizontal displacement of the ocean bottom has been detected with accuracy of several centimeters per year by the GPS/Acoustic positioning of seafloor reference points (Spiess et al. 1998). Meanwhile, bottom pressure observations can record the vertical deformation of seafloor and there have been many challenges to detect vertical seafloor displacement. However, ocean bottom pressure variations are highly dominated by oceanic signals such as tidal and subinertial motions. The tidal and other oceanic variations in bottom pressure records are mostly equivalent to several tens and several centimeters water height anomalies, respectively. Generally, the ocean tide is efficiently corrected. Non-tidal components are required to be accurately removed from the bottom pressure records so that the vertical displacement of less than ten centimeters, the expected amount of displacement caused by slow slip events often observed in several subduction zones, is detected by continuous bottom pressure monitoring. We examine the bottom pressure estimations derived from the Kalman filter and smoother runs of the ECCO (Estimating the Circulation & Climate of the Ocean) product to compare in-situ bottom pressure records. The assimilated bottom pressure moderately represents the seasonal variation, and hardly represents the variation with periods less than a few months. This high frequency variation is mainly explained by the barotropic phenomena induced by meteorological disturbances. Hirose et al. (2001) and Carrère and Lyard (2003) modeled the barotropic ocean motion with the forcing of atmospheric pressure loading and wind over global oceans for the sake of the correction of satellite observations. This study addresses the accurate bottom pressure modeling, which enables us to detect vertical displacement of several centimeters from the in-situ bottom pressure observations. We develop accurate

  20. Corona discharges from a windmill and its lightning protection tower in winter thunderstorms

    Science.gov (United States)

    Wu, Ting; Wang, Daohong; Rison, William; Thomas, Ronald J.; Edens, Harald E.; Takagi, Nobuyuki; Krehbiel, Paul R.

    2017-05-01

    This paper presents lightning mapping array (LMA) observations of corona discharges from a windmill and its lightning protection tower in winter thunderstorms in Japan. Corona discharges from the windmill, called windmill coronas, and those from the tower, called tower coronas, are distinctly different. Windmill coronas occur with periodic bursts, generally radiate larger power, and possibly develop to higher altitudes than tower coronas do. A strong negative electric field is necessary for the frequent production of tower coronas but is not apparently related with windmill coronas. These differences are due to the periodic rotation of the windmill and the moving blades which can escape space charges produced by corona discharges and sustain a large local electric field. The production period of windmill coronas is related with the rotation period of the windmill. Surprisingly, for one rotation of the windmill, only two out of the three blades produce detectable discharges and source powers of discharges from these two blades are different. The reason for this phenomenon is still unclear. For tower coronas, the source rate can get very high only when there is a strong negative electric field, and the source power can get very high only when the source rate is very low. The relationship between corona discharges and lightning flashes is investigated. There is no direct evidence that corona discharges can increase the chance of upward leader initiation, but nearby lightning flashes can increase the source rate of corona discharges right after the flashes. The peak of the source height distribution of corona discharges is about 100 m higher than the top of the windmill and the top of the tower. Possible reasons for this result are discussed.