WorldWideScience

Sample records for strength testing box

  1. Behavior of Reinforced Concrete Hybrid Trapezoidal Box Girders Using Ordinary and Highly Strength Concrete

    Directory of Open Access Journals (Sweden)

    Nameer A. Alawsh

    2018-03-01

    Full Text Available In this paper, the general behavior of reinforced concrete hybrid box girders is studied by experimental and numerical investigation. Experimental work is included casting monolithically five specimens of box girders with trapezoidal cross section and testing it as simply supported under two point loading. Two specimens were cast as homogenous box girders (full normal strength concrete (NSC (about 35 MPa and full high strength concrete (HSC (about 55 MPa and three specimens were cast as hybrid box girders (HSC in upper flange only, HSC in upper flange and half depth of webs, and HSC in bottom flange and total depth of webs. Experimental results showed significant effects of concrete hybridization on the structural behavior of box girders specimens such as: cracking loads, cracking patterns, ultimate strengths, and failure modes. The ultimate strength of Hybrid box girders increased by 23% as average when compared with the homogenous box girder (full NSC and decreased by 9% as average when compared with homogenous box girder (full HSC. In numerical investigation, the tested specimens were modeled and analyzed using three dimensional non-linear finite element analysis. The analysis was carried out by using a computer program (ANSYS V16.1. The numerical results showed an acceptable agreement with the experimental work with difference about (3.12% and 9.588% as average for ultimate load and deflection, respectively.

  2. Structural testing of the technology integration box beam

    Science.gov (United States)

    Griffin, C. F.

    1992-01-01

    A full-scale section of a transport aircraft wing box was designed, analyzed, fabricated, and tested. The wing box section, which was called the technology integration box beam, contained blade stiffened covers and T-stiffened channel spars constructed using graphite/epoxy materials. Covers, spars, and the aluminum ribs were assembled using mechanical fasteners. The box beam was statically tested for several loading conditions to verify the stiffness and strength characteristics of the composite wing design. Failure of the box beam occurred at 125 percent of design limit load during the combined upbending and torsion ultimate design load test. It appears that the failure initiated at a stiffener runout location in the upper cover which resulted in rupture of the upper cover and portions of both spars.

  3. Confirmation test on confinement performance of improved glove box

    International Nuclear Information System (INIS)

    Miura, S.; Kanazawa, J.; Nakajima, M.; Sakuno, K.; Miyata, H.

    1995-01-01

    Glove boxes are used at nuclear facilities to confine radioactive materials by ensuring a high level of airtightness and negative internal pressure. The allowable rate of air leakage is 0.1% vol/hr or less at the pre-service inspection. The negative pressure value is normally maintained at about -30 mm H 2 O. Structural strength and confinement reliability of glove boxes during earthquake are major concerns, and most important glove boxes are designed to withstand seismic class A events is Japan. This paper describes vibration tests done to confirm that improve large-sized glove boxes maintain their confinement performance and structural strength even during earthquake and that the design analysis methods used are appropriate. (author). 1 ref., 6 figs., 3 tabs

  4. A Group Action Method for Construction of Strong Substitution Box

    Science.gov (United States)

    Jamal, Sajjad Shaukat; Shah, Tariq; Attaullah, Atta

    2017-06-01

    In this paper, the method to develop cryptographically strong substitution box is presented which can be used in multimedia security and data hiding techniques. The algorithm of construction depends on the action of a projective general linear group over the set of units of the finite commutative ring. The strength of substitution box and ability to create confusion is assessed with different available analyses. Moreover, the ability of resistance against malicious attacks is also evaluated. The substitution box is examined by bit independent criterion, strict avalanche criterion, nonlinearity test, linear approximation probability test and differential approximation probability test. This substitution box is equated with well-recognized substitution boxes such as AES, Gray, APA, S8, prime of residue, Xyi and Skipjack. The comparison shows encouraging results about the strength of the proposed box. The majority logic criterion is also calculated to analyze the strength and its practical implementation.

  5. Earthquake resistance test of full-scale glove box

    International Nuclear Information System (INIS)

    Fujita, T.; Ohtani, K.; Hayashi, M.; Kozeki, M.; Ide, T.; Sakuno, K.

    1989-01-01

    A glove box used at nuclear facilities must confine radioactive materials. High airtightness and negative internal pressure are used to prevent leaks. The allowable leakage rate of air is 0.1% vol/hr or less at the pre-service inspection. The negative pressure value is kept at - 30 mm H 2 O in normal operation. The glove box structural strength and its confinement reliability during an earthquake are major concerns. The verification of aseismic analysis methods and assumptions for a glove box are thus of great importance. Data on the dynamic behavior of giant glove boxes was recently obtained in large shaker experiments. This paper describes these experimental results and the appropriateness of aseismic analysis methods used in current design

  6. Air-tighten test for used glove boxes

    International Nuclear Information System (INIS)

    Itoh, Masanori; Kashiro, Kashio; Matsumoto, Masaki; Ogiya, Takashi; Nakata, Keiji; Gohda, Masahiko

    2000-05-01

    All of the glove boxes in Plutonium Fuel Fabrication facilities are operated after confirming their condition by conducting negative pressure maintenance test and air-tighten test. Although we check the negative pressure maintenance condition before operating glove boxes in a daily basis, we have not been conducted the air-tighten test. Hence, we have conduct air-tighten test using the glove box that will be dismantled in the near future. In order to compare the present data to the criteria of licensing and to the measurement data for new glove box, the test was conducted by leak tightness vessel which is used the competent authority's test for newly constructed equipments. We also have confirmed the leakage condition in case failure of keeping negative pressure. The main results are as follows: 1. No leakage was detected after leaving the glove box 21 days in case failure of keeping negative pressure condition. 2. The measurement result of the air-tighten test was 0.025 vol%/h, and it was confirmed that this result is within the range of licensing criteria (-0.04 - 0.06 vol%/h). 3. The measurement result was also within the error of leak tightness vessel, and it was confirmed that the air-tighten condition was in force within this past 10 years after installing this glove box (the corresponding value for used the competent authority test for newly constructed equipments was 0.019 vol%/h). (author)

  7. Experimental investigation on ultimate strength and failure response of composite box beams used in wind turbine blades

    DEFF Research Database (Denmark)

    Tang, Jing; Chen, Xiao

    2018-01-01

    This study focuses on the ultimate strength and failure response of composite box beams under three-point bending. The box beams consist of spar caps and shear webs and they are typically used in wind turbine blades as load-carrying members. Different spar cap configurations and loading directions...

  8. Strength of precast concrete shear joints reinforced with high-strength wire ropes

    DEFF Research Database (Denmark)

    Joergensen, Henrik B.; Hoang, Linh Cao; Hagsten, Lars German

    2017-01-01

    This paper concerns the in-plane shear strength of connections between precast concrete wall elements reinforced with looped high-strength wire ropes. The looped wire ropes are pre-installed in so-called ‘wire boxes’ which function as shear keys. Although only a small amount of research...... on the shear strength of such connections can be found in the literature, this type of connection is increasingly being used because wire ropes are much more construction-friendly than traditional U-bars. A rigid plastic upper bound model for the shear strength of wall connections reinforced with looped wire...... ropes that are pre-installed in wire boxes is presented along with test results on the shear strength of connections with double-wire boxes. It is shown that the plastic solution agrees well with both the obtained test results and results from previously conducted tests....

  9. Fire test of DOT 7A Boxes

    International Nuclear Information System (INIS)

    Jensen, J.D.

    1979-05-01

    The primary objective of conducting the full-scale fire tests of the DOT (Department of Transportation) 7A FRP Boxes was to provide information to assist in quantifying the fire hazard of the storage located at the Radioactive Waste Management Complex (RWMC), and to learn if changing the storage array will decrease the fire risk. Also, the level of fire fighting and fire protection required to maintain the risk at the RWMC within acceptable DOE guidelines was investigated. Two full-scale fire tests were conducted at Southwest Research Institute (SwRI) in June 1978, using the DOE 7A FRP Plywood Storage Containers. The fire tests showed that when subjected to a substantial ignition source, the boxes will propagate fire as long as no fire-suppression measures are taken. Fire will breach the boxes and spread the radioactive contaminated waste if it is not extinguished. As the fire progresses, additional boxes will become involved, and eventually the entire storage array will ignite. It is recommended that the use of DOT 7A Boxes be discontinued and replaced with noncombustible storage containers. In the event this is not practicable, guidance recommendations are presented to minimize the large fire loss potential. It is also recommended that an investigation be conducted into the number of boxes that can be destroyed and still maintain a safe environment for employees and the public. This investigation should include how far radioactive contamination will spread, what cleanup will be required, anticipated exposure of the people within the area, and the public impact of such a fire

  10. Box and block test in Beninese adults.

    Science.gov (United States)

    Natta, Ditouah Didier Niama; Alagnidé, Etienne; Kpadonou, Toussaint Godonou; Detrembleur, Christine; Lejeune, Thierry M; Stoquart, Gaëtan G

    2015-11-01

    To determine the Box and Block Test norm in a sub-Saharan population and to compare these data with published norms for North American adults. A total of 692 healthy Beninese people, age range 20-85 years, were recruited. These subjects were asked to perform the Box and Block Test with both hands. Box and Block Test scores (mean and standard deviation (SD)) for women and men were, respectively, 81.3 (15.4) and 79 (16.6) for the dominant hand and 73.2 (13.7) and 72 (14.8) for the non-dominant hand. Mean Box and Block Test scores ranged from 89.1 (12.7) for people under the age of 25 years to 55.23 (10.5) for people over the age of 74 years. Manual dexterity was better for women than men, for dominant hand than non-dominant hand, and for younger subjects. In comparison with published results for US subjects, Beninese subjects had better dexterity below the age of 50 years in both sexes for the right hand and worse dexterity over 64 years of age in both sexes for the right hand. Developing and validating outcome scales in Africa will help to improve functional assessment of African populations in clinical practice and research.

  11. Fatigue Testing of Maglev-Hybrid Box Beam

    Science.gov (United States)

    2009-03-02

    04142009 3. DATES COVERED: (From - To) 23052006-14092008 4. TITLE AND SUBTITLE Fatigue Testing of Maglev -Hybrid Box Beam 5a. CONTRACT NUMBER NA...was previously built under collaboration between Maglev Inc. and Lehigh University. The girder was instrumented with strain gages and LVDT’s to monitor...report March 2,2009 Contract N00014-06-1-0872 Project: Fatigue Testing of Maglev -Hybrid Box Beam Prepared by Dr. J.L. Grenestedt and Dr. R. Sause

  12. Double Length Regressions for Testing the Box-Cox Difference Transformation.

    OpenAIRE

    Park, Timothy

    1991-01-01

    The Box-Cox difference transformation is used to determine the appropriate specification for estimation of hedge ratios and a new double length regression form of the Lagrange multiplier test is presented for the difference transformation. The Box-Cox difference transformation allows the testing of the first difference model and the returns model as special cases of the Box-Cox difference transformation. Copyright 1991 by MIT Press.

  13. S-Boxes Based on Affine Mapping and Orbit of Power Function

    Science.gov (United States)

    Khan, Mubashar; Azam, Naveed Ahmed

    2015-06-01

    The demand of data security against computational attacks such as algebraic, differential, linear and interpolation attacks has been increased as a result of rapid advancement in the field of computation. It is, therefore, necessary to develop such cryptosystems which can resist current cryptanalysis and more computational attacks in future. In this paper, we present a multiple S-boxes scheme based on affine mapping and orbit of the power function used in Advanced Encryption Standard (AES). The proposed technique results in 256 different S-boxes named as orbital S-boxes. Rigorous tests and comparisons are performed to analyse the cryptographic strength of each of the orbital S-boxes. Furthermore, gray scale images are encrypted by using multiple orbital S-boxes. Results and simulations show that the encryption strength of the orbital S-boxes against computational attacks is better than that of the existing S-boxes.

  14. Fatigue strength of the joint between diaphragms and longitudinal ribs in box section girders; Hako danmen keta no diaphragm to shita flange tateribu no kosabu no hiro kyodo

    Energy Technology Data Exchange (ETDEWEB)

    Miki, C.; Shiozaki, M.; Takeishi, K. [Tokyo Institute of Technology, Tokyo (Japan). Faculty of Engineering; Ohashi, H. [Honshu-Shikoku Bridge Authority, Tokyo (Japan)

    1997-04-21

    Discussions were given on crossing joints of diaphragms on hanger fixing sections and U-ribs on lower flanges in reinforcing box girders of a suspension bridge, as to their local stress generating behavior and effects of cope holes on fatigue strength. The test pieces have dimensions and shapes modeling the crossing joints, and the steel materials are SM490YA for upper and lower flanges and webs, and SS400 for U-ribs. The loading test was performed with four-point bending and at loading amplitudes of 30 to 45 tf. Furthermore, stress analysis was conducted by using the finite element method. The following conclusions were obtained as a result: local stress at cope hole tips decreases and fatigue strength increases with the smaller the cope hole diameter; when the cope holes are back-filled completely, deformation is concentrated on welds of the U-ribs and the flanges, generating high local stress; this reduces significantly the fatigue strength of details having no cope holes; and no particular differences are found on effects of boxing of the cope hole tips on the fatigue strength. 7 refs., 10 figs., 3 tabs.

  15. Design and test of box girder for a large wind turbine blade

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Per H.; Tesauro, A.; Bitsche, R. [Technical Univ. of Denmark. DTU Wind Energy, DTU Risoe Campus, Roskilde (Denmark)] [and others

    2012-09-15

    This report is covering the structural design and full scale test of a box girder as a part of the project ''Demonstration of new blade design using manufacturing process simulations'' supported by the EUDP program. A box girder with a predetermined outer geometry was designed using new inventions, which create an inner structure in the box girder. With a combination of advanced FEM analysis and the inventions it was possible to reduce the material thickness of the cap by up to 40%. The new design of the box girder was manufactured at SSP Technology A/S, where it was demonstrated that the manufacturing process could include the new inventions. Subsequently the box girder was transported to the blade test facility at DTU Wind Energy. A series of test was performed with the blade to investigate the behaviour during loading, and finally the girder was loaded to ultimate failure. The report includes the description of the test setup, the test and an overview over the results from the test performed on the box girder. During the final test the box girder failed at 58 % of the expected ultimate load. Unfortunately, no definite conclusion could be made concerning the failure mechanism. (Author)

  16. Design and test of box girder for a large wind turbine blade

    DEFF Research Database (Denmark)

    Nielsen, Per Hørlyk; Tesauro, Angelo; Bitsche, Robert

    This report is covering the structural design and full scale test of a box girder as a part of the project “Demonstration of new blade design using manufacturing process simulations” supported by the EUDP program. A box girder with a predetermined outer geometry was designed using new inventions...... that the manufacturing process could include the new inventions. Subsequently the box girder was transported to the blade test facility at DTU Wind Energy. A series of test was performed with the blade to investigate the behaviour during loading, and finally the girder was loaded to ultimate failure. The report includes...... the description of the test setup, the test and an overview over the results from the test performed on the box girder. During the final test the box girder failed at 58 % of the expected ultimate load. Unfortunately, no definite conclusion could be made concerning the failure mechanism....

  17. To determine the slow shearing rate for consolidation drained shear box tests

    Science.gov (United States)

    Jamalludin, Damanhuri; Ahmad, Azura; Nordin, Mohd Mustaqim Mohd; Hashim, Mohamad Zain; Ibrahim, Anas; Ahmad, Fauziah

    2017-08-01

    Slope failures always occur in Malaysia especially during the rainy seasons. They cause damage to properties and fatalities. In this study, a total of 24 one dimensional consolidation tests were carried out on soil samples taken from 16 slope failures in Penang Island and in Baling, Kedah. The slope failures in Penang Island are within the granitic residual soil while in Baling, Kedah they are situated within the sedimentary residual soil. Most of the disturbed soil samples were taken at 100mm depth from the existing soil surface while some soil samples were also taken at 400, 700 and 1000mm depths from the existing soil surface. They were immediately placed in 2 layers of plastic bag to prevent moisture loss. Field bulk density tests were also carried out at all the locations where soil samples were taken. The field bulk density results were later used to re-compact the soil samples for the consolidation tests. The objective of the research is to determine the slow shearing rate to be used in consolidated drained shear box for residual soils taken from slope failures so that the effective shear strength parameters can be determined. One dimensional consolidation tests were used to determine the slow shearing rate. The slow shearing rate found in this study to be used in the consolidated drained shear box tests especially for Northern Malaysian residual soils was 0.286mm/minute.

  18. Experimental study on buckling and ultimate strength of thin-walled box stub columns; Usuniku hakogata danmen buzai no zakutsu / shukyoku kyodo tokusei ni kansuru jikkenteki kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Nakai, H.; Kitada, T. [Osaka City Univ. (Japan); Oryu, T. [Kawasaki Heavy Industries Ltd., Kobe (Japan)

    1998-10-21

    Thin-walled box stub columns such as beams of cable-stayed bridge, suspension bridge tower, arch rib of arch bridge and steel piers and so forth can also bear torsion at the same time besides compression and bending. These thin-walled box stub columns may achieve ultimate condition before reaching to plastic condition due to the effect of local buckling and so forth. Accordingly, it is the important topic to study the properties regarding ultimate strength of thin-walled box members in order to evaluate correctly the effect on load bearing resistance of local buckling. In this report, validity of load bearing resistance curve and ultimate strength interaction curve proposed by authors was studied using load bearing capacity experiment results. As a result, all ultimate strengths obtained by the experiment were higher than the ultimate strengths estimated by load bearing capacity curve and ultimate strength interaction curve. Further, it was revealed that the specimens subjected to torsion or subjected to bending and torsion and so forth exceeded the plastic strength due to the effect of strain hardening. 12 refs., 14 figs., 4 tabs.

  19. 49 CFR 178.514 - Standards for plywood boxes.

    Science.gov (United States)

    2010-10-01

    ... identification code for a plywood box is 4D. (b) Construction requirements for plywood boxes are as follows: (1..., commercially dry and free from defects that would materially lessen the strength of the box. The strength of the material used and the method of construction must be appropriate to the capacity and intended use...

  20. PVC posting bags for glove boxes

    International Nuclear Information System (INIS)

    1976-12-01

    This specification covers the materials, measurements and manufacture of unpigmented PVC posting bags for use on glove boxes, together with methods of testing the materials. These bags are used in the handling of radioactive and toxic materials of a hazardous nature and therefore must be of the highest standard of mechanical strength, leak tightness and general finish. (author)

  1. Technical task plan for testing filter box sorbent-paint filter test

    International Nuclear Information System (INIS)

    Kilpatrick, L.L.

    1993-01-01

    At the Savannah River Plant, High Level Waste Engineering (HLWE) asked Interim Waste Technology (IWT) to choose and test a sorbent to add to the ITP filter box that meets the EPA requirement for land disposal of containerized liquid hazardous wastes per Paint Filter Liquids (PFL) test method 9095. This report outlines the process to be used in accomplishing this task

  2. CANFLEX fuel bundle strength tests (test report)

    International Nuclear Information System (INIS)

    Chang, Seok Kyu; Chung, C. H.; Kim, B. D.

    1997-08-01

    This document outlines the test results for the strength tests of the CANFLEX fuel bundle. Strength tests are performed to determine and verify the amount of the bundle shape distortion which is against the side-stops when the bundles are refuelling. There are two cases of strength test; one is the double side-stop test which simulates the normal bundle refuelling and the other is the single side-stop test which simulates the abnormal refuelling. the strength test specification requires that the fuel bundle against the side-stop(s) simulators for this test were fabricated and the flow rates were controlled to provide the required conservative hydraulic forces. The test rig conditions of 120 deg C, 11.2 MPa were retained for 15 minutes after the flow rate was controlled during the test in two cases, respectively. The bundle loading angles of number 13- number 15 among the 15 bundles were 67.5 deg CCW and others were loaded randomly. After the tests, the bundle shapes against the side-stops were measured and inspected carefully. The important test procedures and measurements were discussed as follows. (author). 5 refs., 22 tabs., 5 figs

  3. Study on load test of 100m cross-reinforced deck type concrete box arch bridge

    Science.gov (United States)

    Shi, Jing Xian; Cheng, Ying Jie

    2018-06-01

    Found in the routine quality inspection of highway bridge that many vertical fractures on the main beam (10mT beam) of the steel reinforced concrete arch bridge near the hydropower station. In order to grasp the bearing capacity of this bridge under working conditions with cracks, the static load and dynamic load test of box arch bridge are carried out. The Midas civil theory is calculated by using the special plate trailer - 300 as the calculation load, and the deflection and stress of the critical section are tested by the equivalent cloth load in the test vehicle. The pulsation test, obstacles and no obstacle driving test were carried out. Experimental results show that the bridge under the condition of the test loads is in safe condition, main bearing component of the strength and stiffness meet the design requirements, the crack width does not increase, in the process of loading bridge overall work performance is good.

  4. Test procedure for boxed waste assay system

    International Nuclear Information System (INIS)

    Wachter, J.

    1994-01-01

    This document, prepared by Los Alamos National Laboratory's NMT-4 group, details the test methodology and requirements for Acceptance/Qualification testing of a Boxed Waste Assay System (BWAS) designed and constructed by Pajarito Scientific Corporation. Testing of the BWAS at the Plutonium Facility (TA55) at Los Alamos National Laboratory will be performed to ascertain system adherence to procurement specification requirements. The test program shall include demonstration of conveyor handling capabilities, gamma ray energy analysis, and imaging passive/active neutron accuracy and sensitivity. Integral to these functions is the system's embedded operating and data reduction software

  5. An algorithm for the construction of substitution box for block ciphers based on projective general linear group

    Directory of Open Access Journals (Sweden)

    Anas Altaleb

    2017-03-01

    Full Text Available The aim of this work is to synthesize 8*8 substitution boxes (S-boxes for block ciphers. The confusion creating potential of an S-box depends on its construction technique. In the first step, we have applied the algebraic action of the projective general linear group PGL(2,GF(28 on Galois field GF(28. In step 2 we have used the permutations of the symmetric group S256 to construct new kind of S-boxes. To explain the proposed extension scheme, we have given an example and constructed one new S-box. The strength of the extended S-box is computed, and an insight is given to calculate the confusion-creating potency. To analyze the security of the S-box some popular algebraic and statistical attacks are performed as well. The proposed S-box has been analyzed by bit independent criterion, linear approximation probability test, non-linearity test, strict avalanche criterion, differential approximation probability test, and majority logic criterion. A comparison of the proposed S-box with existing S-boxes shows that the analyses of the extended S-box are comparatively better.

  6. Ultimate strength of a large wind turbine blade

    DEFF Research Database (Denmark)

    Jensen, Find Mølholt

    2009-01-01

    reinforcements helping to prevent undesired structural elastic mechanisms are presented. The functionality of two of the suggested structural reinforcements was demonstrated in full-scale tests and the rest trough FE-studies. The blade design under investigation consisted of an aerodynamic airfoil and a load...... carrying box girder. In total, five full-scale tests have been performed involving one complete blade and two shortened box girders. The second box girder was submitted to three independent tests covering different structural reinforcement alternatives. The advantages and disadvantages of testing......The present PhD project contains a study of the structural static strength of wind turbine blades loaded in flap-wise direction. A combination of experimental and numerical work has been used to address the most critical failure mechanisms and to get an understanding of the complex structural...

  7. Boxing headguard performance in punch machine tests.

    Science.gov (United States)

    McIntosh, Andrew S; Patton, Declan A

    2015-09-01

    The paper presents a novel laboratory method for assessing boxing headguard impact performance. The method is applied to examine the effects of headguards on head impact dynamics and injury risk. A linear impactor was developed, and a range of impacts was delivered to an instrumented Hybrid III head and neck system both with and without an AIBA (Association Internationale de Boxe Amateur)-approved headguard. Impacts at selected speeds between 4.1 and 8.3 m/s were undertaken. The impactor mass was approximately 4 kg and an interface comprising a semirigid 'fist' with a glove was used. The peak contact forces were in the range 1.9-5.9 kN. Differences in head impact responses between the Top Ten AIBA-approved headguard and bare headform in the lateral and forehead tests were large and/or significant. In the 8.3 m/s fist-glove impacts, the mean peak resultant headform accelerations for bare headform tests was approximately 130 g compared with approximately 85 g in the forehead impacts. In the 6.85 m/s bare headform impacts, mean peak resultant angular head accelerations were in the range of 5200-5600 rad/s(2) and almost halved by the headguard. Linear and angular accelerations in 45° forehead and 60° jaw impacts were reduced by the headguard. The data support the opinion that current AIBA headguards can play an important role in reducing the risk of concussion and superficial injury in boxing competition and training. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  8. Test Procedure for Axially Loaded Bucket Foundations in Sand (Large Yellow Box)

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina

    This is a practical guide for preparing the soil, running a CPT test, installing a scaled bucket foundation model and running a test in the large yellow sand box cos(Kristina) in the geotechnical laboratory at Aalborg University. The test procedure is used for the examination of statically...... and cyclically axially loaded bucket foundation model In dense sand. The foundation model in scale of approximately 1:10 compared to the prototype size. The guide describes the step-by-step procedure for tests with and without surface pressure. A detailed description of test setup using the large yellow sand box...... for a monopile testing was provided by Thomassen (2015a), procedure for monopile testing can be found in Thomassen (2015b), while safety instructions were given by Vaitkunaite et al. (2014)....

  9. Examination of a Junction-Box Adhesion Test for Use in Photovoltaic Module Qualification: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Miller, D. C.; Wohlgemuth, J. H.

    2012-08-01

    Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test is proposed to verify the basic robustness of its adhesion system. The details of the proposed test will be described, in addition to the preliminary results obtained using representative materials and components. The described discovery experiments examine moisture-cured silicone, foam tape, and hot-melt adhesives used in conjunction with PET or glass module 'substrates.' To be able to interpret the results, a set of material-level characterizations was performed, including thermogravimetric analysis, differential scanning calorimetry, and dynamic mechanical analysis. PV j-boxes were adhered to a substrate, loaded with a prescribed weight, and then placed inside an environmental chamber (at 85C, 85% relative humidity). Some systems did not remain attached through the discovery experiments. Observed failure modes include delamination (at the j-box/adhesive or adhesive/substrate interface) and phase change/creep. The results are discussed in the context of the application requirements, in addition to the plan for the formal experiment supporting the proposed modification to the qualification test.

  10. Accelerated Strength Testing of Thermoplastic Composites

    Science.gov (United States)

    Reeder, J. R.; Allen, D. H.; Bradley, W. L.

    1998-01-01

    Constant ramp strength tests on unidirectional thermoplastic composite specimens oriented in the 90 deg. direction were conducted at constant temperatures ranging from 149 C to 232 C. Ramp rates spanning 5 orders of magnitude were tested so that failures occurred in the range from 0.5 sec. to 24 hrs. (0.5 to 100,000 MPa/sec). Below 204 C, time-temperature superposition held allowing strength at longer times to be estimated from strength tests at shorter times but higher temperatures. The data indicated that a 50% drop in strength might be expected for this material when the test time is increased by 9 orders of magnitude. The shift factors derived from compliance data applied well to the strength results. To explain the link between compliance and strength, a viscoelastic fracture model was investigated. The model, which used compliance as input, was found to fit the strength data only if the critical fracture energy was allowed to vary with temperature reduced stress rate. This variation in the critical parameter severely limits its use in developing a robust time-dependent strength model. The significance of this research is therefore seen as providing both the indication that a more versatile acceleration method for strength can be developed and the evidence that such a method is needed.

  11. Amateur boxing: physical and physiological attributes.

    Science.gov (United States)

    Chaabène, Helmi; Tabben, Montassar; Mkaouer, Bessem; Franchini, Emerson; Negra, Yassine; Hammami, Mehrez; Amara, Samiha; Chaabène, Raja Bouguezzi; Hachana, Younés

    2015-03-01

    Boxing is one of the oldest combat sports. The aim of the current review is to critically analyze the amateur boxer's physical and physiological characteristics and to provide practical recommendations for training as well as new areas of scientific research. High-level male and female boxers show a propensity for low body fat levels. Although studies on boxer somatotypes are limited, the available information shows that elite-level male boxers are characterized by a higher proportion of mesomorphy with a well-developed muscle mass and a low body fat level. To help support the overall metabolic demands of a boxing match and to accelerate the recovery process between rounds, athletes of both sexes require a high level of cardiorespiratory fitness. International boxers show a high peak and mean anaerobic power output. Muscle strength in both the upper and lower limbs is paramount for a fighter's victory and is one of the keys to success in boxing. As boxing punches are brief actions and very dynamic, high-level boxing performance requires well-developed muscle power in both the upper and lower limbs. Albeit limited, the available studies reveal that isometric strength is linked to high-level boxing performance. Future investigations into the physical and physiological attributes of boxers are required to enrich the current data set and to help create a suitable training program.

  12. Standard Waste Box Lid Screw Removal Option Testing

    International Nuclear Information System (INIS)

    Anast, Kurt Roy

    2016-01-01

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  13. Standard Waste Box Lid Screw Removal Option Testing

    Energy Technology Data Exchange (ETDEWEB)

    Anast, Kurt Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  14. Generalized Majority Logic Criterion to Analyze the Statistical Strength of S-Boxes

    Science.gov (United States)

    Hussain, Iqtadar; Shah, Tariq; Gondal, Muhammad Asif; Mahmood, Hasan

    2012-05-01

    The majority logic criterion is applicable in the evaluation process of substitution boxes used in the advanced encryption standard (AES). The performance of modified or advanced substitution boxes is predicted by processing the results of statistical analysis by the majority logic criteria. In this paper, we use the majority logic criteria to analyze some popular and prevailing substitution boxes used in encryption processes. In particular, the majority logic criterion is applied to AES, affine power affine (APA), Gray, Lui J, residue prime, S8 AES, Skipjack, and Xyi substitution boxes. The majority logic criterion is further extended into a generalized majority logic criterion which has a broader spectrum of analyzing the effectiveness of substitution boxes in image encryption applications. The integral components of the statistical analyses used for the generalized majority logic criterion are derived from results of entropy analysis, contrast analysis, correlation analysis, homogeneity analysis, energy analysis, and mean of absolute deviation (MAD) analysis.

  15. Probe tests microweld strength

    Science.gov (United States)

    1965-01-01

    Probe is developed to test strength of soldered, brazed or microwelded joints. It consists of a spring which may be adjusted to the desired test pressure by means of a threaded probe head, and an indicator lamp. Device may be used for electronic equipment testing.

  16. Structural Testing of a Stitched/Resin Film Infused Graphite-Epoxy Wing Box

    Science.gov (United States)

    Jegley, Dawn C.; Bush, Harold G.

    2001-01-01

    The results of a series of tests conducted at the NASA Langley Research Center to evaluate the behavior of an all-composite full-scale wing box are presented. The wing box is representative of a section of a 220-passenger commercial transport aircraft wing box and was designed and constructed by The Boeing Company as part of the NASA Advanced Subsonics Technology (AST) program. The semi-span wing was fabricated from a graphite-epoxy material system with cover panels and spars held together using Kevlar stitches through the thickness. No mechanical fasteners were used to hold the stiffeners to the skin of the cover panels. Tests were conducted with and without low-speed impact damage, discrete source damage and repairs. Up-bending, down-bending and brake roll loading conditions were applied. The structure with non-visible impact damage carried 97% of Design Ultimate Load prior to failure through a lower cover panel access hole.

  17. Testing of a Stitched Composite Large-Scale Multi-Bay Pressure Box

    Science.gov (United States)

    Jegley, Dawn; Rouse, Marshall; Przekop, Adam; Lovejoy, Andrew

    2016-01-01

    NASA has created the Environmentally Responsible Aviation (ERA) Project to develop technologies to reduce aviation's impact on the environment. A critical aspect of this pursuit is the development of a lighter, more robust airframe to enable the introduction of unconventional aircraft configurations. NASA and The Boeing Company have worked together to develop a structural concept that is lightweight and an advancement beyond state-of-the-art composite structures. The Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) is an integrally stiffened panel design where elements are stitched together. The PRSEUS concept is designed to maintain residual load carrying capabilities under a variety of damage scenarios. A series of building block tests were evaluated to explore the fundamental assumptions related to the capability and advantages of PRSEUS panels. The final step in the building block series is an 80%-scale pressure box representing a portion of the center section of a Hybrid Wing Body (HWB) transport aircraft. The testing of this article under maneuver load and internal pressure load conditions is the subject of this paper. The experimental evaluation of this article, along with the other building block tests and the accompanying analyses, has demonstrated the viability of a PRSEUS center body for the HWB vehicle. Additionally, much of the development effort is also applicable to traditional tube-and-wing aircraft, advanced aircraft configurations, and other structures where weight and through-the-thickness strength are design considerations.

  18. Analysis of S-box in Image Encryption Using Root Mean Square Error Method

    Science.gov (United States)

    Hussain, Iqtadar; Shah, Tariq; Gondal, Muhammad Asif; Mahmood, Hasan

    2012-07-01

    The use of substitution boxes (S-boxes) in encryption applications has proven to be an effective nonlinear component in creating confusion and randomness. The S-box is evolving and many variants appear in literature, which include advanced encryption standard (AES) S-box, affine power affine (APA) S-box, Skipjack S-box, Gray S-box, Lui J S-box, residue prime number S-box, Xyi S-box, and S8 S-box. These S-boxes have algebraic and statistical properties which distinguish them from each other in terms of encryption strength. In some circumstances, the parameters from algebraic and statistical analysis yield results which do not provide clear evidence in distinguishing an S-box for an application to a particular set of data. In image encryption applications, the use of S-boxes needs special care because the visual analysis and perception of a viewer can sometimes identify artifacts embedded in the image. In addition to existing algebraic and statistical analysis already used for image encryption applications, we propose an application of root mean square error technique, which further elaborates the results and enables the analyst to vividly distinguish between the performances of various S-boxes. While the use of the root mean square error analysis in statistics has proven to be effective in determining the difference in original data and the processed data, its use in image encryption has shown promising results in estimating the strength of the encryption method. In this paper, we show the application of the root mean square error analysis to S-box image encryption. The parameters from this analysis are used in determining the strength of S-boxes

  19. A NEW CLINICAL MUSCLE FUNCTION TEST FOR ASSESSMENT OF HIP EXTERNAL ROTATION STRENGTH: AUGUSTSSON STRENGTH TEST.

    Science.gov (United States)

    Augustsson, Jesper

    2016-08-01

    Dynamic clinical tests of hip strength applicable on patients, non-athletes and athletes alike, are lacking. The aim of this study was therefore to develop and evaluate the reliability of a dynamic muscle function test of hip external rotation strength, using a novel device. A second aim was to determine if gender differences exist in absolute and relative hip strength using the new test. Fifty-three healthy sport science students (34 women and 19 men) were tested for hip external rotation strength using a device that consisted of a strap connected in series with an elastic resistance band loop, and a measuring tape connected in parallel with the elastic resistance band. The test was carried out with the subject side lying, positioned in 45 ° of hip flexion and the knees flexed to 90 ° with the device firmly fastened proximally across the knees. The subject then exerted maximal concentric hip external rotation force against the device thereby extending the elastic resistance band. The displacement achieved by the subject was documented by the tape measure and the corresponding force production was calculated. Both right and left hip strength was measured. Fifteen of the subjects were tested on repeated occasions to evaluate test-retest reliability. No significant test-retest differences were observed. Intra-class correlation coefficients ranged 0.93-0.94 and coefficients of variation 2.76-4.60%. In absolute values, men were significantly stronger in hip external rotation than women (right side 13.2 vs 11.0 kg, p = 0.001, left side 13.2 vs 11.5 kg, p = 0.002). There were no significant differences in hip external rotation strength normalized for body weight (BW) between men and women (right side 0.17 kg/BW vs 0.17 kg/BW, p = 0.675, left side 0.17 kg/BW vs 0.18 kg/BW, p = 0.156). The new muscle function test showed high reliability and thus could be useful for measuring dynamic hip external rotation strength in patients, non-athletes and athletes

  20. Maximal Strength Testing in Healthy Children.

    Science.gov (United States)

    Faigenbaum, Avery D.; Milliken, Laurie A.; Westcott, Wayne L.

    2003-01-01

    Evaluated the safety and efficacy of 1 repetition maximum (1RM) strength testing in healthy children age 6-12 years. Data were collected on 96 children who performed a 1RM test on one upper body and one lower body exercise using child-sized weight machines. Findings indicated that children could safely perform 1RM strength tests provided…

  1. Neurological tests improve after Olympic-style boxing bouts: a pretournament and post-tournament study in the 2016 Women's World Boxing Championships.

    Science.gov (United States)

    Howell, David R; Meehan, William P; Loosemore, Michael P; Cummiskey, Joseph; Grabner von Rosenberg, Jean-Paul; McDonagh, David

    2017-09-01

    To prospectively examine the neurocognitive, postural, dual-task and visual abilities of female Olympic-style boxers before and after participation in a tournament. Sixty-one females completed the modified Balance Error Scoring System (mBESS), King-Devick test and 3 m timed-up-and-go test in single-task and dual-task conditions. A subset (n=31) completed the CogState computerised neurocognitive test. Initial testing was completed prior to the 2016 Women's World Boxing Championships; each participant repeated the testing protocol within a day of elimination. No participant sustained a concussion. Pretournament and post-tournament performance variables were compared using paired t-tests or Wilcoxon signed-rank tests. Participants completed a mean of 7.5±4.5 rounds of Olympic-style boxing over 2-8 days. Post-tournament scores were significantly lower than pretournament scores for total mBESS (2.2±1.9 errors vs 5.5±2.9 errors, pboxing tournament (maze chase task: 1.39±0.34 correct moves/second vs 1.17±0.44 correct moves/second, p=0.001, d =0.58). No significant changes across time were detected for the other obtained outcome variables. Female boxers demonstrated either improvement or no significant changes in test performance after competing in an Olympic-style boxing tournament, relative to pretournament performance. As many of the test tasks were novel for the boxers, practice effects may have contributed to improved performance. When there is a short time frame between assessments, clinicians should be aware of potential practice effects when using ringside neurological tests. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Full Scale Test of a SSP 34m box girder 1. Data report

    DEFF Research Database (Denmark)

    Jensen, Find Mølholt; Branner, Kim; Nielsen, Per Hørlyk

    This report presents the setup and result of a full-scale test of a reinforced glass fibre/epoxy box girder used in 34m wind turbine blade. The tests were performed at the Blaest test facility in August 2006. The test is an important part of a research project established in cooperation between...... Risø DTU, the National Laboratory for Sustainable Energy at the Technical University of Denmark -, SSP-Technology A/S and Blaest (Blade test centre A/S) and it has been performed as a part of Find Mølholt Jensen‟s PhD study. This report contains the complete test data for the final test, in which...... the box girder was loaded until failure. A comprehensive description of the test setup is given. This report deals only with tests and results. There are no conclusions on the data in this report, but references are given to publications, where the data are used and compared with FEM etc. Various kinds...

  3. Simulation of the Test Method "L-Box" for Self-Compacting Concrete

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm; Szabo, Peter; Geiker, Mette Rica

    2004-01-01

    Both filling and passing ability are important properties to be considered for self-compacting concrete. This paper presents simulations of the L-box test and corresponding experiments. The assumption of a continuum mechanical approach, where the fluid rheology is described by the Bingham model...

  4. The influence of main bar corrosion on bond strength in selfcompacting concrete

    Science.gov (United States)

    Ayop, S. S.; Emhemed, A. N. K.; Jamaluddin, N.; Sadikin, A.

    2017-11-01

    The experimental study was conducted to determine the influence of main bar corrosion on bond strength in self-compacting concrete (SCC). A total 16 tension pullout tests specimens reinforced with 10 mm and 14 mm diameter bar were used for the bond strength test. The properties of SCC were determined from the slump flow, T50cm, V-funnel and L box test. Reinforcing bars in the concrete were submitted to impressed current to accelerate the corrosion of the bar. It was found that the relationship between bond strength and concrete strength in un-corroded specimens differed from that of corroded specimens set in high-strength concrete because of brittleness in the corroded specimens, which caused a sudden loss of bond strength. The results revealed that specimens of un-corroded and corroded showed a higher percentage of bond strength degradation during the pullout tests.

  5. Construction and test of a box system for operations with air-sensitive and radioactive compounds

    International Nuclear Information System (INIS)

    Kuenstler, K.; Betzl, K.; Grosser, H.J.; Furkert, W.; Novotny, D.

    1985-06-01

    A system of mechanical components has been develoed, which can be used to design inert atmosphere boxes as well as radioactive boxes. The advantage in comparison with known designs consists in the modular construction principle which permits variable dimensions. Standard parts (flanges, bushings, air locks and so on) possess a uniform size. The system for the maintenance of a high-purity atmosphere in the box has been improved, decreasing the level of oxygen and water vapour below 10 vpm. The low impurity level in the inert atmosphere is attained by means of continuous circulation of the gases through a purification system. The usefulness of the boxes for handling air-sensitive and radioactive compounds has been tested over a period of some years. (author)

  6. Sex differences in a human analogue of the Radial Arm Maze: the "17-Box Maze Test".

    Science.gov (United States)

    Rahman, Qazi; Abrahams, Sharon; Jussab, Fardin

    2005-08-01

    This study investigated sex differences in spatial memory using a human analogue of the Radial Arm Maze: a revision on the Nine Box Maze originally developed by called the 17-Box Maze Test herein. The task encourages allocentric spatial processing, dissociates object from spatial memory, and incorporates a within-participants design to provide measures of location and object, working and reference memory. Healthy adult males and females (26 per group) were administered the 17-Box Maze Test, as well as mental rotation and a verbal IQ test. Females made significantly fewer errors on this task than males. However, post hoc analysis revealed that the significant sex difference was specific to object, rather than location, memory measures. These were medium to large effect sizes. The findings raise the issue of task- and component-specific sexual dimorphism in cognitive mapping.

  7. Black-Box Search by Unbiased Variation

    DEFF Research Database (Denmark)

    Lehre, Per Kristian; Witt, Carsten

    2012-01-01

    The complexity theory for black-box algorithms, introduced by Droste, Jansen, and Wegener (Theory Comput. Syst. 39:525–544, 2006), describes common limits on the efficiency of a broad class of randomised search heuristics. There is an obvious trade-off between the generality of the black-box model...... and the strength of the bounds that can be proven in such a model. In particular, the original black-box model provides for well-known benchmark problems relatively small lower bounds, which seem unrealistic in certain cases and are typically not met by popular search heuristics.In this paper, we introduce a more...... restricted black-box model for optimisation of pseudo-Boolean functions which we claim captures the working principles of many randomised search heuristics including simulated annealing, evolutionary algorithms, randomised local search, and others. The key concept worked out is an unbiased variation operator...

  8. Effects of a sitting boxing program on upper limb function, balance, gait, and quality of life in stroke patients.

    Science.gov (United States)

    Park, Junhyuck; Gong, Jihwan; Yim, Jongeun

    2017-01-01

    Boxing training including traditional stretching, muscular strength training, and duration training would be considered to be effective for improved functional stretching, dynamic balance, walking speed, and quality of life. We aimed to investigate upper limb function, balance, gait, and quality of life in stroke patients before and after a sitting boxing program. Twenty-six participants were randomly allocated to a boxing group (n = 13) and control group (n = 13) after the upper limb function, balance, gait, and quality of Life were recorded. The boxing group underwent a sitting boxing program (3 times/week) as well as conventional physical therapy (3 times/week) for 6 weeks. The control group only underwent conventional physical therapy (3 times/week) for 6 weeks. The Manual Functional Test (MFT), non-affected hand grip, Berg Balance Scale (BBS), velocity moment with eye opened, 10-m Walk Test (10 MWT), and Stroke-Specific Quality of Life questionnaire (SS-QOL) were significantly improved in the boxing group (p boxing group compared to the control group (p boxing program group had positive effects on upper extremity function, balance, gait, and quality of life in stroke patients.

  9. CONDUCTING AND ANALYZING THE RESULTS OF THE EXPERIMENTAL BOX TEST OF RETAINING WALL MODELS WITHOUT PILES AND ON THE PILE FOUNDATION

    Directory of Open Access Journals (Sweden)

    M. A. Lisnevskyi

    2015-08-01

    Full Text Available Purpose. Taking into consideration that the bearing capacity of the foundation may be insufficient, in the study it is assumed that pile foundation can be used to reduce the impact of the construction of new retaining structures on roads and railways near the existing buildings or in areas of dense urban development and ensure the stability of the foundation. To reduce the volume of excavation it is necessary to choose the economic structure of the retaining wall. To do this, one should explore stress-strain state (SSS of the retaining walls, to develop methods to improve their strength and stability, as well as to choose the most appropriate method of their analysis. Methodology. In the design of retaining walls foundation mat and piles are considered as independent elements. Since the combined effect of the retaining wall, piles and foundation mat as well as the effect of soil or rock foundation on the structure are considered not fully, so there are some limitations in the existing design techniques. To achieve the purpose the box tests of retaining walls models without piles and with piles for studying their interaction with the surrounding soil massif were conducted. Findings. Laboratory simulation of complex systems «surrounding soil – retaining wall – pile» was carried out and on the basis of the box test results were analyzed strains and its main parameters of the stress-strain state. Analysis of the results showed that the structure of a retaining wall with piles is steady and stable. Originality. So far, in Ukraine has not been carried out similar experimental box tests with models of retaining walls in such combinations. In the article has been presented unique photos and test results, as well as their analysis. Practical value. Using the methodology of experimental tests of the retaining wall models with piles and without them gives a wider opportunity to study stress-strain state of such structures.

  10. High-Strength Composite Fabric Tested at Structural Benchmark Test Facility

    Science.gov (United States)

    Krause, David L.

    2002-01-01

    Large sheets of ultrahigh strength fabric were put to the test at NASA Glenn Research Center's Structural Benchmark Test Facility. The material was stretched like a snare drum head until the last ounce of strength was reached, when it burst with a cacophonous release of tension. Along the way, the 3-ft square samples were also pulled, warped, tweaked, pinched, and yanked to predict the material's physical reactions to the many loads that it will experience during its proposed use. The material tested was a unique multi-ply composite fabric, reinforced with fibers that had a tensile strength eight times that of common carbon steel. The fiber plies were oriented at 0 and 90 to provide great membrane stiffness, as well as oriented at 45 to provide an unusually high resistance to shear distortion. The fabric's heritage is in astronaut space suits and other NASA programs.

  11. Testing among functional forms: an extension of the Generalized Box-Cox formulation.

    NARCIS (Netherlands)

    Oude Lansink, A.G.J.M.; Thijssen, G.

    1998-01-01

    This paper uses the Generalized Box - Cox framework and Double Length artificial Regression to test whether different specifications of the profit function are able to mimic the technology underlying panel data of Dutch arable farms for the period 1970 - 1988. To this end, a linear GBC is developed

  12. Culture-independent diagnostic testing: have we opened Pandora's box for good?

    Science.gov (United States)

    Janda, J Michael; Abbott, Sharon A

    2014-11-01

    The ability to accurately and quickly identify microbial agents associated with infectious diseases has been a longstanding and continuous goal of diagnostic microbiology laboratories. Over the course of several decades, technology and testing methodologies in this field have gradually evolved from traditional- or classic-based culture and identification approaches to antigen capture systems and more molecular-oriented applications. Recently, these molecular-based applications have signaled a new era in clinical diagnostic microbiology with the commercial introduction of culture-independent diagnostic testing (CIDT) systems. The first major commercial venture into the CIDT arena involves the detection of acute bacterial gastroenteritis. Several commercial products are now on the market globally with at least 4 Food and Drug Administration approved since January of 2013. These new systems offer the direct detection of a variety of enteropathogens quickly without the need for traditional culture. In Greek mythology, Pandora opened a "jar" or "box" out of curiosity thereby releasing all of humanity's evils most notably diseases and plagues according to Hesiod's Theogony. While not ill-intentioned the only thing left in the box was Hope. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Chairside CAD/CAM materials. Part 2: Flexural strength testing.

    Science.gov (United States)

    Wendler, Michael; Belli, Renan; Petschelt, Anselm; Mevec, Daniel; Harrer, Walter; Lube, Tanja; Danzer, Robert; Lohbauer, Ulrich

    2017-01-01

    Strength is one of the preferred parameters used in dentistry for determining clinical indication of dental restoratives. However, small dimensions of CAD/CAM blocks limit reliable measurements with standardized uniaxial bending tests. The objective of this study was to introduce the ball-on-three-ball (B3B) biaxial strength test for dental for small CAD/CAM block in the context of the size effect on strength predicted by the Weibull theory. Eight representative chairside CAD/CAM materials ranging from polycrystalline zirconia (e.max ZirCAD, Ivoclar-Vivadent), reinforced glasses (Vitablocs Mark II, VITA; Empress CAD, Ivoclar-Vivadent) and glass-ceramics (e.max CAD, Ivoclar-Vivadent; Suprinity, VITA; Celtra Duo, Dentsply) to hybrid materials (Enamic, VITA; Lava Ultimate, 3M ESPE) have been selected. Specimens were prepared with highly polished surfaces in rectangular plate (12×12×1.2mm 3 ) or round disc (Ø=12mm, thickness=1.2mm) geometries. Specimens were tested using the B3B assembly and the biaxial strength was determined using calculations derived from finite element analyses of the respective stress fields. Size effects on strength were determined based on results from 4-point-bending specimens. A good agreement was found between the biaxial strength results for the different geometries (plates vs. discs) using the B3B test. Strength values ranged from 110.9MPa (Vitablocs Mark II) to 1303.21MPa (e.max ZirCAD). The strength dependency on specimen size was demonstrated through the calculated effective volume/surface. The B3B test has shown to be a reliable and simple method for determining the biaxial strength restorative materials supplied as small CAD/CAM blocks. A flexible solution was made available for the B3B test in the rectangular plate geometry. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. The Relationship Between Hip Strength and the Y-Balance Test.

    Science.gov (United States)

    Wilson, Benjamin R; Robertson, Kaley E; Burnham, Jeremy M; Yonz, Michael C; Ireland, Mary Lloyd; Noehren, Brian

    2017-07-17

    The Y-Balance Test was developed as a test of dynamic postural control and has been shown to be predictive of lower extremity injury. However, the relationship between hip strength and performance on the Y-Balance Test has not been fully elucidated. The goal of this study was to identify the relationship between components of isometric hip strength and the Y-Balance Test, to provide clinicians better guidance as to specific areas of muscle performance to address in the event of poor performance on the Y-Balance Test. Laboratory Study. Biomechanics Laboratory. Seventy-three healthy participants, 40 males and 33 females, volunteered for this study. None. Participants completed the Y-Balance Test on the right leg. We then measured peak isometric torque in hip external rotation, abduction, and extension. Correlations were calculated between torque measurements, normalized for mass, and Y-Balance Test performance. Significant relationships were used in linear regression models to determine which variables were predictive of the Y-Balance Test performance. We found significant positive correlations between Y-Balance Test performance and hip abduction strength. We also found correlations between the Y-Balance Test and hip extension and external rotation strengths. Linear regression analysis showed hip abduction to be the only significant predictor of Y- Balance performance. We found the strongest association between the Y-Balance Test and hip abduction strength. We also showed smaller but significant associations with hip extension and external rotation strength. When entered into a linear regression analysis, hip abduction strength was the only significant predictor of Y-Balance performance. Using this information, practitioners should look to hip abduction strength when patients exhibit deficits in the Y-Balance Test.

  15. Analysis and Test Correlation of Proof of Concept Box for Blended Wing Body-Low Speed Vehicle

    Science.gov (United States)

    Spellman, Regina L.

    2003-01-01

    The Low Speed Vehicle (LSV) is a 14.2% scale remotely piloted vehicle of the revolutionary Blended Wing Body concept. The design of the LSV includes an all composite airframe. Due to internal manufacturing capability restrictions, room temperature layups were necessary. An extensive materials testing and manufacturing process development effort was underwent to establish a process that would achieve the high modulus/low weight properties required to meet the design requirements. The analysis process involved a loads development effort that incorporated aero loads to determine internal forces that could be applied to a traditional FEM of the vehicle and to conduct detailed component analyses. A new tool, Hypersizer, was added to the design process to address various composite failure modes and to optimize the skin panel thickness of the upper and lower skins for the vehicle. The analysis required an iterative approach as material properties were continually changing. As a part of the material characterization effort, test articles, including a proof of concept wing box and a full-scale wing, were fabricated. The proof of concept box was fabricated based on very preliminary material studies and tested in bending, torsion, and shear. The box was then tested to failure under shear. The proof of concept box was also analyzed using Nastran and Hypersizer. The results of both analyses were scaled to determine the predicted failure load. The test results were compared to both the Nastran and Hypersizer analytical predictions. The actual failure occurred at 899 lbs. The failure was predicted at 1167 lbs based on the Nastran analysis. The Hypersizer analysis predicted a lower failure load of 960 lbs. The Nastran analysis alone was not sufficient to predict the failure load because it does not identify local composite failure modes. This analysis has traditionally been done using closed form solutions. Although Hypersizer is typically used as an optimizer for the design

  16. Validity and test-retest reliability of a novel simple back extensor muscle strength test.

    Science.gov (United States)

    Harding, Amy T; Weeks, Benjamin Kurt; Horan, Sean A; Little, Andrew; Watson, Steven L; Beck, Belinda Ruth

    2017-01-01

    To develop and determine convergent validity and reliability of a simple and inexpensive clinical test to quantify back extensor muscle strength. Two testing sessions were conducted, 7 days apart. Each session involved three trials of standing maximal isometric back extensor muscle strength using both the novel test and isokinetic dynamometry. Lumbar spine bone mineral density was examined by dual-energy X-ray absorptiometry. Validation was examined with Pearson correlations ( r ). Test-retest reliability was examined with intraclass correlation coefficients and limits of agreement. Pearson correlations and intraclass correlation coefficients are presented with corresponding 95% confidence intervals. Linear regression was used to examine the ability of peak back extensor muscle strength to predict indices of lumbar spine bone mineral density and strength. A total of 52 healthy adults (26 men, 26 women) aged 46.4 ± 20.4 years were recruited from the community. A strong positive relationship was observed between peak back extensor strength from hand-held and isokinetic dynamometry ( r  = 0.824, p  strength test, short- and long-term reliability was excellent (intraclass correlation coefficient = 0.983 (95% confidence interval, 0.971-0.990), p  strength measures with the novel back extensor strength protocol were -6.63 to 7.70 kg, with a mean bias of +0.71 kg. Back extensor strength predicted 11% of variance in lumbar spine bone mineral density ( p  strength ( p  strength is quick, relatively inexpensive, and reliable; demonstrates initial convergent validity in a healthy population; and is associated with bone mass at a clinically important site.

  17. Numerical study on shear resisting mechanism for corroded RC box culverts

    International Nuclear Information System (INIS)

    Matsuo, Toyofumi; Matsumura, Takuro; Iwamori, Akiyuki

    2013-01-01

    This paper discusses the effects of reinforcing steel corrosion on the shear resisting mechanism of RC box culverts and the applicability of the material degradation model in a finite element method. First, in FEM analyses, loss of reinforcement section area and initial tension strain due to reinforcement corrosion, and deteriorated bond characteristics between reinforcement and concrete, were considered. Second, cyclic loading tests using full-scale corroded specimens were numerically analyzed. The analyzed crack patterns and load-displacement relationships up to the maximum load were observed to be in close agreement with the experiment results within the average corrosion ratio of 10% of primary reinforcement. The fact that corrosion cracks can importantly affect the progression of shear cracks and shear strength of RC beams was also found. On the other hand, we established that RC box culverts being statically indeterminate structures, sectional forces are redistributed after cracking damage, and local material deterioration has a minor effect on shear capacity. Furthermore, a parametric study was carried out for corroded RC box culverts using parameters such as size, steel corrosion location, and corrosion level. (author)

  18. Strength testing and training of rowers: a review.

    Science.gov (United States)

    Lawton, Trent W; Cronin, John B; McGuigan, Michael R

    2011-05-01

    In the quest to maximize average propulsive stroke impulses over 2000-m racing, testing and training of various strength parameters have been incorporated into the physical conditioning plans of rowers. Thus, the purpose of this review was 2-fold: to identify strength tests that were reliable and valid correlates (predictors) of rowing performance; and, to establish the benefits gained when strength training was integrated into the physical preparation plans of rowers. The reliability of maximal strength and power tests involving leg extension (e.g. leg pressing) and arm pulling (e.g. prone bench pull) was high (intra-class correlations 0.82-0.99), revealing that elite rowers were significantly stronger than their less competitive peers. The greater strength of elite rowers was in part attributed to the correlation between strength and greater lean body mass (r = 0.57-0.63). Dynamic lower body strength tests that determined the maximal external load for a one-repetition maximum (1RM) leg press (kg), isokinetic leg extension peak force (N) or leg press peak power (W) proved to be moderately to strongly associated with 2000-m ergometer times (r = -0.54 to -0.68; p training experience and muscle morphology, in that those individuals with greater training experience and/or proportions of slow twitch fibres performed more repetitions. Muscle balance ratios derived from strength data (e.g. hamstring-quadriceps ratio training may be counterproductive to strength development over the shorter term (i.e. training within the sequence of training units should be considered, particularly over the non-competition phase (e.g. 2-6 sets × 4-12 repetitions, three sessions a week). Maximal strength was sustained when infrequent (e.g. one or two sessions a week) but intense (e.g. 73-79% of maximum) strength training units were scheduled; however, it was unclear whether training adaptations should emphasize maximal strength, endurance or power in order to enhance

  19. Strength Testing in Motor Neuron Diseases.

    Science.gov (United States)

    Shefner, Jeremy M

    2017-01-01

    Loss of muscle strength is a cardinal feature of all motor neuron diseases. Functional loss over time, including respiratory dysfunction, inability to ambulate, loss of ability to perform activities of daily living, and others are due, in large part, to decline in strength. Thus, the accurate measurement of limb muscle strength is essential in therapeutic trials to best understand the impact of therapy on vital function. While qualitative strength measurements show declines over time, the lack of reproducibility and linearity of measurement make qualitative techniques inadequate. A variety of quantitative measures have been developed; all have both positive attributes and limitations. However, with careful training and reliability testing, quantitative measures have proven to be reliable and sensitive indicators of both disease progression and the impact of experimental therapy. Quantitative strength measurements have demonstrated potentially important therapeutic effects in both amyotrophic lateral sclerosis and spinobulbar muscular atrophy, and have been shown feasible in children with spinal muscular atrophy. The spectrum of both qualitative and quantitative strength measurements are reviewed and their utility examined in this review.

  20. Seismic stability of a standalone glove box structure

    Energy Technology Data Exchange (ETDEWEB)

    Saraswat, A., E-mail: anupams@barc.gov.in [Bhabha Atomic Research Centre, Mumbai (India); Reddy, G.R. [Bhabha Atomic Research Centre, Mumbai (India); Ghosh, S. [Indian Institute of Technology Bombay, Mumbai (India); Ghosh, A.K.; Kumar, Arun [Bhabha Atomic Research Centre, Mumbai (India)

    2014-09-15

    Highlights: • Glove box is a leak tight, safety related structure used for handling radiotoxic materials. • To study the seismic performance of a freestanding glove box, extensive shake table testing has been carried out. • Glove box maintained structural integrity and leak tightness up to design basis earthquake loading. • Detailed three-dimensional finite element model of the structure is developed and analyzed by using direct time integration methods. • Simplified numerical method is proposed and successfully applied, to quickly estimate sliding displacement and determine upper bounds for it. - Abstract: In a nuclear fuel cycle facility, radiotoxic materials are being handled in freestanding leak tight enclosures called glove boxes (GBs). These glove boxes act as a primary confinement for the radiotoxic materials. Glove boxes are designed as per codal requirements for class I component. They are designed to withstand extreme level of earthquake loading with a return period of 10,000 years. To evaluate seismic performance of the glove box, there is a need to check the stability (sliding and overturning), structural integrity (stresses and strains) and leak tightness under earthquake loading. Extensive shake table experiments were conducted on a single standalone glove box. Actual laboratory conditions were simulated during testing to check the response. After extensive shake table testing, glove box structure was also analyzed using finite element (FE) software. Detailed three-dimensional model of glove box structure was developed and analyzed using nonlinear time history method. It was observed that finite element methods could be utilized to accurately predict dynamic response of glove box structure. This paper discusses the details and results of shake table testing and methodology used for modelling and analysing freestanding glove box structure under seismic loading. In addition, simplified numerical procedure, developed using energy conservation

  1. Seismic stability of a standalone glove box structure

    International Nuclear Information System (INIS)

    Saraswat, A.; Reddy, G.R.; Ghosh, S.; Ghosh, A.K.; Kumar, Arun

    2014-01-01

    Highlights: • Glove box is a leak tight, safety related structure used for handling radiotoxic materials. • To study the seismic performance of a freestanding glove box, extensive shake table testing has been carried out. • Glove box maintained structural integrity and leak tightness up to design basis earthquake loading. • Detailed three-dimensional finite element model of the structure is developed and analyzed by using direct time integration methods. • Simplified numerical method is proposed and successfully applied, to quickly estimate sliding displacement and determine upper bounds for it. - Abstract: In a nuclear fuel cycle facility, radiotoxic materials are being handled in freestanding leak tight enclosures called glove boxes (GBs). These glove boxes act as a primary confinement for the radiotoxic materials. Glove boxes are designed as per codal requirements for class I component. They are designed to withstand extreme level of earthquake loading with a return period of 10,000 years. To evaluate seismic performance of the glove box, there is a need to check the stability (sliding and overturning), structural integrity (stresses and strains) and leak tightness under earthquake loading. Extensive shake table experiments were conducted on a single standalone glove box. Actual laboratory conditions were simulated during testing to check the response. After extensive shake table testing, glove box structure was also analyzed using finite element (FE) software. Detailed three-dimensional model of glove box structure was developed and analyzed using nonlinear time history method. It was observed that finite element methods could be utilized to accurately predict dynamic response of glove box structure. This paper discusses the details and results of shake table testing and methodology used for modelling and analysing freestanding glove box structure under seismic loading. In addition, simplified numerical procedure, developed using energy conservation

  2. Reactive Strength Index: A Poor Indicator of Reactive Strength?

    Science.gov (United States)

    Healy, Robin; Kenny, Ian; Harrison, Drew

    2017-11-28

    The primary aim was to assess the relationships between reactive strength measures and associated kinematic and kinetic performance variables achieved during drop jumps. A secondary aim was to highlight issues with the use of reactive strength measures as performance indicators. Twenty eight national and international level sprinters, consisting of fourteen men and women, participated in this cross-sectional analysis. Athletes performed drop jumps from a 0.3 m box onto a force platform with dependent variables contact time (CT), landing time (TLand), push-off time (TPush), flight time (FT), jump height (JH), reactive strength index (RSI, calculated as JH / CT), reactive strength ratio (RSR, calculated as FT / CT) and vertical leg spring stiffness (Kvert) recorded. Pearson's correlation test found very high to near perfect relationships between RSI and RSR (r = 0.91 to 0.97), with mixed relationships found between RSI, RSR and the key performance variables, (Men: r = -0.86 to -0.71 between RSI/RSR and CT, r = 0.80 to 0.92 between RSI/RSR and JH; Women: r = -0.85 to -0.56 between RSR and CT, r = 0.71 between RSI and JH). This study demonstrates that the method of assessing reactive strength (RSI versus RSR) may be influenced by the performance strategies adopted i.e. whether an athlete achieves their best reactive strength scores via low CTs, high JHs or a combination. Coaches are advised to limit the variability in performance strategies by implementing upper and / or lower CT thresholds to accurately compare performances between individuals.

  3. Response of steel box columns in fire conditions

    Directory of Open Access Journals (Sweden)

    Mahmood Yahyai

    2017-05-01

    Full Text Available Effect of elevated temperatures on the mechanical properties of steel, brings the importance of investigating the effect of fire on the steel structures anxiously. Columns, as the main load-carrying part of a structure, can be highly vulnerable to the fire. In this study, the behavior of steel gravity columns with box cross section exposed to fire has been investigated. These kinds of columns are widely used in common steel structures design in Iran. In current study, the behavior of such columns in fire conditions is investigated through the finite element method. To perform this, the finite element model of a steel column which has been previously tested under fire condition, was prepared. Experimental loading and boundary conditions were considered in the model and was analyzed. Results were validated by experimental data and various specimens of gravity box columns were designed according to the Iran’s steel buildings code, and modeled and analyzed using Abaqus software. The effect of width to thickness ratio of column plates, the load ratio and slenderness on the ultimate strength of the column was investigated, and the endurance time was estimated under ISO 834 standard fire curve. The results revealed that an increase in width to thickness ratio and load ratio leads to reduction of endurance time and the effect of width to thickness ratio on the ultimate strength of the column decreases with temperature increase.

  4. The Heuristic Interpretation of Box Plots

    Science.gov (United States)

    Lem, Stephanie; Onghena, Patrick; Verschaffel, Lieven; Van Dooren, Wim

    2013-01-01

    Box plots are frequently used, but are often misinterpreted by students. Especially the area of the box in box plots is often misinterpreted as representing number or proportion of observations, while it actually represents their density. In a first study, reaction time evidence was used to test whether heuristic reasoning underlies this…

  5. Compressive strength measurements of hybrid dental composites treated with dry heat and light emitting diodes (LED post cure treatment

    Directory of Open Access Journals (Sweden)

    Jenny Krisnawaty

    2014-11-01

    Full Text Available Hybrid composites are mostly used on large cavities as restorative dental materials, whether it is used directly or indirectly. The mechanical properties of composite resin shall increase if it is treated with post cure treatment. The aim of this study is to evaluate compressive strength differences between dry heat and Light Emitting Diodes (LED treatment on the hybrid dental composite. A quasi-experimental was applied on this research with a total of 30 samples that were divided into two groups. Each sample was tested using LLOYD Universal Testing Machine with 1 mm/min speed to evaluate the compressive strength. The compressive strength results were marked when the sample was broken. The results of two groups were then analyzed using t-test statistical calculation. The results of this study show that post cure treatment on hybrid composite using LED light box (194.138 MPa was lower than dry heat treatment (227.339 MPa, which was also significantly different from statistical analysis. It can be concluded that compressive strength of LED light box was lower than dry heat post-cure treatment on the hybrid composite resin.

  6. Strength evaluation test of pressureless-sintered silicon nitride at room temperature

    Science.gov (United States)

    Matsusue, K.; Takahara, K.; Hashimoto, R.

    1984-01-01

    In order to study strength characteristics at room temperature and the strength evaluating method of ceramic materials, the following tests were conducted on pressureless sintered silicon nitride specimens: bending tests, the three tensile tests of rectangular plates, holed plates, and notched plates, and spin tests of centrally holed disks. The relationship between the mean strength of specimens and the effective volume of specimens are examined using Weibull's theory. The effect of surface grinding on the strength of specimens is discussed.

  7. Strength of Ship Stiffened Panels under Combined Loading

    DEFF Research Database (Denmark)

    Weicheng, Cui; Wang, Young-jun; Pedersen, Preben Terndrup

    2000-01-01

    A ship's hull is a box girder structure composed of stiffened panels and therefore, strength of stiffened panels plays a significant role for the ultimate strength analysis of ship structures. In recent years several authors have proposed simplified methods to calculate the ultimate strength of s...

  8. 16 CFR 1203.16 - Dynamic strength of retention system test.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Dynamic strength of retention system test.... (2) The retention system strength test equipment shall consist of a dynamic impact apparatus that... stirrup. (2) Mark the pre-test position of the retention system, with the entire dynamic test apparatus...

  9. Speaker box made of composite particle board based on mushroom growing media waste

    Science.gov (United States)

    Tjahjanti, P. H.; Sutarman, Widodo, E.; Kurniawan, A. R.; Winarno, A. T.; Yani, A.

    2017-06-01

    This research aimed to use mushroom growing media waste (MGMW) that was added by urea, starch and polyvinyl chloride (PVC) glue as a composite particle board to be used as the material of speaker box manufacture. Physical and mechanical testing of particle board including density, moisture content, thickness swelling after immersion in water, strength in water absorption, internal bonding, modulus of elasticity, modulus of rupture and screw holding power, were carried out in accordance with the Stándar Nasional Indonesia (SNI) 03-2105-2006 and Japanese International Standard (JIS) A 5908-2003. The optimum composition of composite particle boards was 60% MGMW + 39% (50% urea +50% starch) + 1% PVC glue. Furthermore, the optimum composition to create speaker box with hardness values of 14.9 Brinnel Hardness Number and results of vibration test obtained amplitude values of the Z-axis, minimum of 0.032007 and maximum of 0.151575. For the acoustic test, results showed good sound absorption coefficients at frequencies of 500 Hz and it has better damping absorption.

  10. Multistep triaxial strength tests: investigating strength parameters and pore pressure effects on Opalinus Clay

    International Nuclear Information System (INIS)

    Graesle, W.

    2010-01-01

    Document available in extended abstract form only. The impact of natural variability between rock samples from a single formation is a common problem for the characterisation of THM properties of rocks. Data variation arising from heterogeneity between samples often obscures details of material behaviour. Besides efforts to reduce this statistical noise by careful selection of samples, there are essentially two approaches to overcome this problem: - To generate very large data sets for better statistics. - To avoid the impact of natural variability by yielding an extensive data set from a single sample. The multistep strength test follows the latter approach to characterise the mechanical behaviour of Opalinus Clay from Mont Terri and the possible impact of pore pressure effects. The concept of the multistep strength test comprises three test sections, each focused on the investigation of one mechanical characteristic of Opalinus Clay. Any section is composed of a series of strain controlled load cycles at various levels of confining pressure. 1) The linear elastic limit, i.e. the onset of nonlinearity in the stress-strain-relationship σ dev (ε 1 ) during strain-controlled triaxial loading, is determined in section 1. It defines a lower limit for the onset of damage. Avoiding sample damage is essential during this test section to ensure that all measurements reflect the behaviour of undisturbed material. Therefore, a rather strict and well detectable criterion for the onset of nonlinearity is required to enable a timely termination of any load phase. 2) Section 2 is focused on shear strength. Any load cycle is stopped as soon as peak stress is detected. As progressive damage of the sample is unavoidable during this process, it must be expected that only very few measured peak stresses approximately represent properties of the undamaged material. 3) Test section 3 is a conventional test of residual strength. Tests are carried out on cylindrical samples (100 mm

  11. Strength of wood versus rate of testing - A theoretical approach

    DEFF Research Database (Denmark)

    Nielsen, Lauge Fuglsang

    2007-01-01

    Strength of wood is normally measured in ramp load experiments. Experience shows that strength increases with increasing rate of testing. This feature is considered theoretically in this paper. It is shown that the influence of testing rate is a phenomenon, which depends on the quality...... of the considered wood. Low quality wood shows lesser influence of testing rate. This observation agrees with the well-known statement made by Borg Madsen that weak wood subjected to a constant load, has a longer lifetime than strong wood. In general, the influence of testing rate on strength increases...

  12. Developing and user-testing Decision boxes to facilitate shared decision making in primary care - a study protocol

    Directory of Open Access Journals (Sweden)

    Rousseau François

    2011-03-01

    Full Text Available Abstract Background Applying evidence is one of the most challenging steps of evidence-based clinical practice. Healthcare professionals have difficulty interpreting evidence and translating it to patients. Decision boxes are summaries of the most important benefits and harms of diagnostic, therapeutic, and preventive health interventions provided to healthcare professionals before they meet the patient. Our hypothesis is that Decision boxes will prepare clinicians to help patients make informed value-based decisions. By acting as primers, the boxes will enhance the application of evidence-based practices and increase shared decision making during the clinical encounter. The objectives of this study are to provide a framework for developing Decision boxes and testing their value to users. Methods/Design We will begin by developing Decision box prototypes for 10 clinical conditions or topics based on a review of the research on risk communication. We will present two prototypes to purposeful samples of 16 family physicians distributed in two focus groups, and 32 patients distributed in four focus groups. We will use the User Experience Model framework to explore users' perceptions of the content and format of each prototype. All discussions will be transcribed, and two researchers will independently perform a hybrid deductive/inductive thematic qualitative analysis of the data. The coding scheme will be developed a priori from the User Experience Model's seven themes (valuable, usable, credible, useful, desirable, accessible and findable, and will include new themes suggested by the data (inductive analysis. Key findings will be triangulated using additional publications on the design of tools to improve risk communication. All 10 Decision boxes will be modified in light of our findings. Discussion This study will produce a robust framework for developing and testing Decision boxes that will serve healthcare professionals and patients alike. It

  13. Evaluation of microtensile and tensile bond strength tests ...

    African Journals Online (AJOL)

    2015-11-03

    Nov 3, 2015 ... Bond strength tests and Er,Cr:YSGG laser frequency. 586 ... power, 90% air pressure, 75% water pressure, 45 s irradiation ..... geometry on the measurement of the tensile bond strength to dentin. J Dent ... Bur‑cut enamel and.

  14. Role of non-destructive examinations in leak testing of glove boxes for industrial scale plutonium handling at nuclear fuel fabrication facility along with case study

    International Nuclear Information System (INIS)

    Aher, Sachin

    2015-01-01

    Non Destructive Examinations has the prominent role at Nuclear Fuel Fabrication Facilities. Specifically NDE has contributed at utmost stratum in Leak Testing of Glove Boxes and qualifying them as a Class-I confinement for safe Plutonium handling at industrial scale. Advanced Fuel Fabrication Facility, BARC, Tarapur is engaged in fabrication of Plutonium based MOX (PuO 2 , DDUO 2 ) fuel with different enrichments for first core of PFBR reactor. Alpha- Leak Tight Glove Boxes along with HEPA Filters and dynamic ventilation form the promising engineering system for safe and reliable handling of plutonium bearing materials considering the radiotoxicity and risk associated with handling of plutonium. Leak Testing of Glove Boxes which involves the leak detection, leak rectification and leak quantifications is major challenging task. To accomplish this challenge, various Non Destructive Testing methods have assisted in promising way to achieve the stringent leak rate criterion for commissioning of Glove Box facilities for plutonium handling. This paper highlights the Role of various NDE techniques like Soap Solution Test, Argon Sniffer Test, Pressure Drop/Rise Test etc. in Glove Box Leak Testing along with procedure and methodology for effective rectification of leakage points. A Flow Chart consisting of Glove Box leak testing procedure starting from preliminary stage up to qualification stage along with a case study and observations are discussed in this paper. (author)

  15. [A test of the focusing hypothesis for category judgment: an explanation using the mental-box model].

    Science.gov (United States)

    Hatori, Tsuyoshi; Takemura, Kazuhisa; Fujii, Satoshi; Ideno, Takashi

    2011-06-01

    This paper presents a new model of category judgment. The model hypothesizes that, when more attention is focused on a category, the psychological range of the category gets narrower (category-focusing hypothesis). We explain this hypothesis by using the metaphor of a "mental-box" model: the more attention that is focused on a mental box (i.e., a category set), the smaller the size of the box becomes (i.e., a cardinal number of the category set). The hypothesis was tested in an experiment (N = 40), where the focus of attention on prescribed verbal categories was manipulated. The obtained data gave support to the hypothesis: category-focusing effects were found in three experimental tasks (regarding the category of "food", "height", and "income"). The validity of the hypothesis was discussed based on the results.

  16. Flexural strength of proof-tested and neutron-irradiated silicon carbide

    Science.gov (United States)

    Price, R. J.; Hopkins, G. R.

    1982-08-01

    Proof testing before service is a valuable method for ensuring the reliability of ceramic structures. Silicon carbide has been proposed as a very low activation first-wall and blanket structural material for fusion devices, where it would experience a high flux of fast neutrons. Strips of three types of silicon carbide were loaded in four-point bending to a stress sufficient to break about a third of the specimens. Groups of 16 survivors were irradiated to 2 × 10 26n/ m2 ( E>0.05 MeV) at 740°C and bend tested to failure. The strength distribution of chemically vapor-deposited silicon carbide (Texas Instruments) was virtually unchanged by irradiation. The mean strength of sintered silicon carbide (Carborundum Alpha) was reduced 34% by irradiation, while the Weibull modulus and the truncated strength distribution characteristic of proof-tested material were retained. Irradiation reduced the mean strength of reaction-bonded silicon carbide (Norton NC-430) by 58%, and the spread in strength values was increased. We conclude that for the chemically vapor-deposited and the sintered silicon carbide the benefits of proof testing to eliminate low strength material are retained after high neutron exposures.

  17. Aerodynamic drag reduction tests on a box-shaped vehicle

    Science.gov (United States)

    Peterson, R. L.; Sandlin, D. R.

    1981-01-01

    The intent of the present experiment is to define a near optimum value of drag coefficient for a high volume type of vehicle through the use of a boattail, on a vehicle already having rounded front corners and an underbody seal, or fairing. The results of these tests will constitute a baseline for later follow-on studies to evaluate candidate methods of obtaining afterbody drag coefficients approaching the boattail values, but without resorting to such impractical afterbody extensions. The current modifications to the box-shaped vehicle consisted of a full and truncated boattail in conjunction with the faired and sealed underbody. Drag results from these configurations are compared with corresponding wind tunnel results of a 1/10 scale model. Test velocities ranged up to 96.6 km/h (60 mph) and the corresponding Reynolds numbers ranged up to 1.3 x 10 to the 7th power based on the vehicles length which includes the boattail. A simple coast-down technique was used to define drag.

  18. Full scale test of a SSP 34m box girder 1. Data report; Reinforced glass fiber/expoxy used in wind turbine blades

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Find M.; Branner, K.; Nielsen, Per H. (and others)

    2008-03-15

    This report presents the setup and result of a full-scale test of a reinforced glass fibre/epoxy box girder used in 34m wind turbine blade. The tests were performed at the Blaest test facility in August 2006. The test is an important part of a research project established in cooperation between Risoe DTU, the National Laboratory for Sustainable Energy at the Technical University of Denmark -, SSP-Technology A/S and Blaest (Blade test centre A/S) and it has been performed as a part of Find Moelholt Jensen's PhD study. This report contains the complete test data for the final test, in which the box girder was loaded until failure. A comprehensive description of the test setup is given. This report deals only with tests and results. There are no conclusions on the data in this report, but references are given to publications, where the data are used and compared with FEM etc. Various kinds of measuring equipment have been used during these tests: acoustic emission, 330 strain gauges, 24 mechanical displacement devices and two optical deformation measuring systems. The mechanical displacement devices measured both global (absolute) and local (relative) deflection and the optical systems measured surface deformation. A prediction was made on the location of the failure of the girder. At this location the majority of the measuring equipment was concentrated. The prediction was proved to be correct and valuable information of the behaviour of the box girder prior to failure was obtained. The experimental investigation consisted of the following load configurations: -Flapwise bending -Torsion Ultrasonic scanning of the box girder was performed before, during and after the test the box girder. This was done to investigate whether the girder was damaged by the load or imperfection (productions defects) growth. (au)

  19. Strength Tests on Hulls and Floats

    Science.gov (United States)

    Matthaes, K

    1942-01-01

    The present report deals with strength tests on hulls and floats intended in part for the collection of construction data for the design of these components and in part for the stress analysis of the finished hulls and floats.

  20. Opto-Box

    CERN Document Server

    Bertsche, David; The ATLAS collaboration; Welch, Steven; Smith, Dale Shane; Che, Siinn; Gan, K.K.; Boyd, George Russell Jr

    2015-01-01

    The opto-box is a custom mini-crate for housing optical modules, which process and transfer optoelectronic data. The system tightly integrates electrical, mechanical, and thermal functionality into a small package of size 35x10x8 cm^3. Special attention was given to ensure proper shielding, grounding, cooling, high reliability, and environmental tolerance. The custom modules, which incorporate Application Specific Integrated Circuits (ASICs), were developed through a cycle of rigorous testing and redesign. In total, fourteen opto-boxes have been installed and loaded with modules on the ATLAS detector. They are currently in operation as part of the LHC run 2 data read-out chain.

  1. The applicability of a multitask boxing program using the BoxMaster ® for Parkinson’s disease

    OpenAIRE

    Domingos, Josefa; Loureiro, Rita; Godinho, Catarina; Dean, John; Ferreira, Joaquim J.

    2016-01-01

    Poster presented at the 4th World Parkinson Congress. Portland, Oregon, 20-23 September 2016 "Objective: To test the applicability of a multitasking boxing program using the BoxMaster® in individuals with Parkinson’s disease that combines motor, cognitive and vocal exercises." N/A

  2. Decontamination of TRU glove boxes

    International Nuclear Information System (INIS)

    Crawford, J.H.

    1978-03-01

    Two glove boxes that had been used for work with transuranic nuclides (TRU) for about 12 years were decontaminated in a test program to collect data for developing a decontamination facility for large equipment highly contaminated with alpha emitters. A simple chemical technique consisting of a cycle of water flushes and alkaline permanganate and oxalic acid washes was used for both boxes. The test showed that glove boxes and similar equipment that are grossly contaminated with transuranic nuclides can be decontaminated to the current DIE nonretrievable disposal guide of <10 nCi TRU/g with a moderate amount of decontamination solution and manpower. Decontamination of the first box from an estimated 1.3 Ci to about 5 mCi (6 nCi/g) required 1.3 gallons of decontamination solution and 0.03 man-hour of work for each square foot of surface area. The second box was decontaminated from an estimated 3.4 Ci to about 2.8 mCi (4.2 nCi/g) using 0.9 gallon of decontamination solution and 0.02 man-hour for each square foot of surface area. Further reductions in contamination were achieved by repetitive decontamination cycles, but the effectiveness of the technique decreased sharply after the initial cycle

  3. Nondestructive test for estimating strength of concrete in structure

    International Nuclear Information System (INIS)

    Nozaki, Yoshitsugu; Soshiroda, Tomozo

    1997-01-01

    Evaluation of the quality of concrete in structures, especially strength estimation is said to be one of the most important problem and needed to establish test method especial tv for non-destructive method in situ. The paper describes the nondestructive test to estimate strength of concrete. From experimental study using full scale model wall, strength estimating equations are proposed by ultra-sonic pulse velocity, rebound hardness of Schmidt hammer and combined with two methods. From statistical study of the results of experiments, errors of estimated strength by the proposed equations are suggested. The validity of the equations are verified by investigation for existing reinforced concrete buildings aged 20 - 50 years. And it was found from the statistical study that the strength estimating equations need to be corrected in applying to tons aged concrete, and correction factor to those squat ions were suggested. Furthermore the corrected proposed equations were verified by applying to buildings investigated the other case.

  4. Ultimate strength of a large wind turbine blade

    Energy Technology Data Exchange (ETDEWEB)

    Moelholt Jensen, Find

    2008-05-15

    The present PhD project contains a study of the structural static strength of wind turbine blades loaded in flap-wise direction. A combination of experimental and numerical work has been used to address the most critical failure mechanisms and to get an understanding of the complex structural behaviour of wind turbine blades. Four failure mechanisms observed during the fullscale tests and the corresponding FE-analysis are presented. Elastic mechanisms associated with failure, such as buckling, localized bending and the Brazier effect, are studied. Six different types of structural reinforcements helping to prevent undesired structural elastic mechanisms are presented. The functionality of two of the suggested structural reinforcements was demonstrated in full-scale tests and the rest trough FE-studies. The blade design under investigation consisted of an aerodynamic airfoil and a load carrying box girder. In total, five full-scale tests have been performed involving one complete blade and two shortened box girders. The second box girder was submitted to three independent tests covering different structural reinforcement alternatives. The advantages and disadvantages of testing a shortened load carrying box girder vs. an entire blade are discussed. Changes in the boundary conditions, loads and additional reinforcements, which were introduced in the box girder tests in order to avoid undesired structural elastic mechanisms, are presented. New and advanced measuring equipment was used in the fullscale tests to detect the critical failure mechanisms and to get an understanding of the complex structural behaviour. Traditionally, displacement sensors and strain gauges in blade tests are arranged based on an assumption of a Bernoulli-Euler beam structural response. In the present study it is shown that when following this procedure important information about distortions of the cross sections is lost. In the tests presented here, one of the aims was to measure distortion

  5. Enhancing Security of Double Random Phase Encoding Based on Random S-Box

    Science.gov (United States)

    Girija, R.; Singh, Hukum

    2018-06-01

    In this paper, we propose a novel asymmetric cryptosystem for double random phase encoding (DRPE) using random S-Box. While utilising S-Box separately is not reliable and DRPE does not support non-linearity, so, our system unites the effectiveness of S-Box with an asymmetric system of DRPE (through Fourier transform). The uniqueness of proposed cryptosystem lies on employing high sensitivity dynamic S-Box for our DRPE system. The randomness and scalability achieved due to applied technique is an additional feature of the proposed solution. The firmness of random S-Box is investigated in terms of performance parameters such as non-linearity, strict avalanche criterion, bit independence criterion, linear and differential approximation probabilities etc. S-Boxes convey nonlinearity to cryptosystems which is a significant parameter and very essential for DRPE. The strength of proposed cryptosystem has been analysed using various parameters such as MSE, PSNR, correlation coefficient analysis, noise analysis, SVD analysis, etc. Experimental results are conferred in detail to exhibit proposed cryptosystem is highly secure.

  6. Loads experiments study on two-story RC box and truncated conical walls

    International Nuclear Information System (INIS)

    Asega, H.; Iizuka, S.; Kurihara, I.; Kubo, T.

    1987-01-01

    The failure modes of the two specimens were the sliding shear failure. The two specimens showed almost equal deformation at the maximum shear strength. The ratio of the flexural deformation in the deformation of the truncated conical was larger than that of the box wall. The ratio of the shear deformation in the deformation of the two-story RC box wall was larger than that of the flexural deformation. (orig./HP)

  7. Evaluation of acceptance strength tests for concrete pavements.

    Science.gov (United States)

    2005-06-30

    The North Carolina Department of Transportation has used traditionally flexural strength tests for acceptance : testing of Portland cement concrete pavements. This report summarizes a research project implemented to : investigate the feasibility of u...

  8. Opto-Box

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00377159; The ATLAS collaboration

    2016-01-01

    The opto-box is a custom mini-crate for housing optical modules, which process and transfer optoelectronic data. Many novel solutions were developed for the custom design and manufacturing. The system tightly integrates electrical, mechanical, and thermal functionality into a small package of size 35x10x8 cm$^{3}$. Special attention was given to ensure proper shielding, grounding, cooling, high reliability, and environmental tolerance. The custom modules, which incorporate Application Specific Integrated Circuits (ASICs), were developed through a cycle of rigorous testing and redesign. In total, fourteen opto-boxes have been installed and loaded with modules on the ATLAS detector. They are currently in operation as part of the LHC run 2 data read-out chain.

  9. Long-term outcome of muscle strength in ulnar and median nerve injury: Comparing manual muscle strength testing, grip and pinch strength dynamometers and a new intrinsic muscle strength dynamometer

    NARCIS (Netherlands)

    A.R. Schreuders (Ton); M.E. Roebroeck (Marij); J.B. Jaquet (Jean); S.E.R. Hovius (Steven); H.J. Stam (Henk)

    2004-01-01

    textabstractObjective: To compare the outcome of muscle strength with manual muscle strength testing grip and pinch strength measurements and a dynamometer which allows for measurements of the intrinsic muscles of the hand in isolation (the Rotterdam Intrinsic Hand Myometer, RIHM). Methods:

  10. IMPACTS OF DIFFERENT JOINT ANGLES AND ADHESIVES ON DIAGONAL TENSION PERFORMANCES OF BOX-TYPE FURNITURE

    Directory of Open Access Journals (Sweden)

    Musa Atar

    2010-02-01

    Full Text Available The goal of this study was to determine the effects of different joint angles and adhesives on diagonal tension performances of the box-type furniture made from solid wood and medium density fiberboard (MDF. After drilling joints of 75º, 78º, 81º, 84º, and 87º degrees on Oriental beech, European oak, Scotch pine, and MDF samples, a diagonal tensile test was applied on corners glued with polyvinyl acetate (PVAc and polyurethane (D-VTKA = Desmodur-Vinyl Trieketonol Acetate according to ASTM D 1037 standard. With reference to the obtained results, the highest tensile strength was obtained in European oak with PVAc glue and joint angle of 84º, while the lowest value was obtained in MDF with D-VTKA glue and joint angle of 75º. Considering the interaction of wood, adhesive, and joint angle, the highest tensile strength was obtained in European oak with joint angle of 81º and D-VTKA glue (1.089 N.mm-2, whereas the lowest tensile strength was determined in MDF with joint angle of 75º and PVAc glue (0.163 N.mm-2. Therefore, PVAc as glue and 81º as joint angle could be suggested to obtain some advantageous on the dovetail joint process for box-type furniture made from both solid wood and MDF.

  11. Yield strengths of tungsten-base composites determined from bend tests

    International Nuclear Information System (INIS)

    Zukas, E.G.; Eash, D.T.

    1976-08-01

    The variation in yield strength with either strain rate or temperature was determined for a number of tungsten-base composites by use of the simple three-point bend test. The yield strengths were comparable with those obtained in standard tensile tests. Additional studies on 1019 steel, either in the as-rolled or annealed condition, gave results in agreement with handbook values, as did two aluminum alloys. These results demonstrate that the bend test deserves wider acceptance in materials testing programs

  12. Exergaming boxing versus heavy-bag boxing: are these equipotent for individuals with spinal cord injury?

    Science.gov (United States)

    Mat Rosly, Maziah; Mat Rosly, Hadi; Hasnan, Nazirah; Davis, Glen M; Husain, Ruby

    2017-08-01

    Current strategies for increased physical activity and exercise in individuals with spinal cord injury (SCI) face many challenges with regards to maintaining their continuity of participation. Barriers cited often include problems with accessing facilities, mundane, monotonous or boring exercises and expensive equipment that is often not adapted for wheelchair users. To compare the physiological responses and user preferences between conventional heavy-bag boxing against a novel form of video game boxing, known as exergaming boxing. Cross-sectional study. Exercise laboratory setting in a university medical center. Seventeen participants with SCI were recruited, of which sixteen were male and only one female. Their mean age was 35.6±10.2 years. All of them performed a 15-minute physical exercise session of exergaming and heavy-bag boxing in a sitting position. The study assessed physiological responses in terms of oxygen consumption, metabolic equivalent (MET) and energy expenditure between exergaming and heavy-bag boxing derived from open-circuit spirometry. Participants also rated their perceived exertion using Borg's category-ratio ratings of perceived exertion. Both exergaming (MET: 4.3±1.0) and heavy-bag boxing (MET: 4.4±1.0) achieved moderate exercise intensities in these participants with SCI. Paired t-test revealed no significant differences (P>0.05, Cohen's d: 0.02-0.49) in the physiological or perceived exertional responses between the two modalities of boxing. Post session user survey reported all the participants found exergaming boxing more enjoyable. Exergaming boxing, was able to produce equipotent physiological responses as conventional heavy-bag boxing. The intensity of both exercise modalities achieved recommended intensities for health and fitness benefits. Exergaming boxing have the potential to provide an enjoyable, self-competitive environment for moderate-vigorous exercise even at the comfort of their homes.

  13. [Effect of genotype and day or night time of testing on mice behavior in the light-dark box and the open-field tests].

    Science.gov (United States)

    Morozova, M V; Kulikov, A V

    2010-01-01

    The light-dark box (LDB) and the open-field (OF) tests are widespread experimental models for studying locomotion and anxiety in laboratory rats and mice. The fact that rodents are nocturnal animals and more active at night raises a critical question of whether behavioral experiments carried out in the light phase are methodologically correct. Parameters of behavior of four mouse strains (C57BL/6J, DBA2/J, AKR/J and CBA/LacJ) in the light-dark box and open-field tests in the light and dark phases were compared. No significant influence of the phase of testing on anxiety in LDB and OF tests was revealed. In the OF test CBA mice showed increased locomotor activity, whereas AKR and C57BL/6 mice showed increased defecation in the dark phase. It was concluded that: 1) the phase of testing is not crucial for the expression of anxiety in LDB and OF; 2) the sensitivity to the phase of testing depends on the genotype; 3) the indices of behavior in the genotypes sensitive to the phase of testing (locomotion in the CBA and defecation in the AKR and C57BL/6 mouse strains) are increased in the dark phase.

  14. Load carrying capacity of keyed joints reinforced with high strength wire rope loops

    DEFF Research Database (Denmark)

    Jørgensen, Henrik B.; Hoang, Linh Cao

    2015-01-01

    friendly shear connection can be obtained by replacing the U-bars with high strength looped wire ropes. The wire ropes have the advantage of being flexible (they have virtually no bending stiffness) which makes installation of wall elements much easier. The looped wire ropes are usually pre-installed in so......-called wire boxes which are embedded in the precast wall elements. Once the joint is grouted with mortar, the boxes will function as shear keys and the overlapping wire loops will function as transverse reinforcement that replaces the U-bars. This paper presents a rigid-plastic upper bound model to determine...... the shear capacity of wire loop connections. Tests have shown that the shear capacity of such joints – due to the relatively high tensile strength of the wire ropes - is more prone to be governed by fracture of the joint mortar in combination with yielding of the locking bar. To model this type of failure...

  15. Characterization for capillary barriers effects in a sand box test using time-lapsed GPR measurements

    Science.gov (United States)

    Kuroda, S.; Ishii, N.; Morii, T.

    2017-12-01

    Capillary barriers have been known as the method to protect subsurface regions against infiltration from soil surface. It is caused by essentially heterogeneous structure in permeability or soil physical property and produce non-uniform infiltration process then, in order to estimate the actual situation of the capillary barrier effect, the site-characterization with imaging technique like geophysical prospecting is effective. In this study, we examine the applicability of GPR to characterization for capillary barriers. We built a sand box with 90x340x90cm in which a thin high-permeable gravel layer was embedded as a capillary barrier. We conducted an infiltration test in the sand box using porous tube array for irrigation. It is expected to lead to non-uniform flow of soil water induced by capillary barrier effects. We monitored this process by various types of GPR measurements, including time-lapsed common offset profiling (COP) with multi- frequency antenna and transmission measurements like cross-borehole radar. At first, we conducted GPR common-offset survey. It could show the depth of capillary barrier in sand box. After that we conducted the infiltration test and GPR monitoring for infiltration process. GPR profiles can detect the wetting front and estimate water content change in the soil layer above the capillary barrier. From spatial change in these results we can estimate the effect of capillary barrier and the zone where the break through occur or not. Based on these results, we will discuss the applicability of GPR for monitoring the phenomena around the capillary barrier of soil. At first, we conducted GPR common-offset survey. It could show the depth of capillary barrier in sand box. After that we conducted the infiltration test and GPR monitoring for infiltration process. GPR profiles can detect the wetting front and estimate water content change in the soil layer above the capillary barrier. From spatial change in these results we can estimate the

  16. Strength and Pain Threshold Handheld Dynamometry Test Reliability in Patellofemoral Pain.

    Science.gov (United States)

    van der Heijden, R A; Vollebregt, T; Bierma-Zeinstra, S M A; van Middelkoop, M

    2015-12-01

    Patellofemoral pain syndrome (PFPS), characterized by peri- and retropatellar pain, is a common disorder in young, active people. The etiology is unclear; however, quadriceps strength seems to be a contributing factor, and sensitization might play a role. The study purpose is determining the inter-rater reliability of handheld dynamometry to test both quadriceps strength and pressure pain threshold (PPT), a measure for sensitization, in patients with PFPS. This cross-sectional case-control study comprises 3 quadriceps strength and one PPT measurements performed by 2 independent investigators in 22 PFPS patients and 16 matched controls. Inter-rater reliability was analyzed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Inter-rater reliability of quadriceps strength testing was fair to good in PFPS patients (ICC=0.72) and controls (ICC=0.63). Bland-Altman plots showed an increased difference between assessors when average quadriceps strength values exceeded 250 N. Inter-rater reliability of PPT was excellent in patients (ICC=0.79) and fair to good in controls (ICC=0.52). Handheld dynamometry seems to be a reliable method to test both quadriceps strength and PPT in PFPS patients. Inter-rater reliability was higher in PFPS patients compared to control subjects. With regard to quadriceps testing, a higher variance between assessors occurs when quadriceps strength increases. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Effect of Box-Cox transformation on power of Haseman-Elston and maximum-likelihood variance components tests to detect quantitative trait Loci.

    Science.gov (United States)

    Etzel, C J; Shete, S; Beasley, T M; Fernandez, J R; Allison, D B; Amos, C I

    2003-01-01

    Non-normality of the phenotypic distribution can affect power to detect quantitative trait loci in sib pair studies. Previously, we observed that Winsorizing the sib pair phenotypes increased the power of quantitative trait locus (QTL) detection for both Haseman-Elston (HE) least-squares tests [Hum Hered 2002;53:59-67] and maximum likelihood-based variance components (MLVC) analysis [Behav Genet (in press)]. Winsorizing the phenotypes led to a slight increase in type 1 error in H-E tests and a slight decrease in type I error for MLVC analysis. Herein, we considered transforming the sib pair phenotypes using the Box-Cox family of transformations. Data were simulated for normal and non-normal (skewed and kurtic) distributions. Phenotypic values were replaced by Box-Cox transformed values. Twenty thousand replications were performed for three H-E tests of linkage and the likelihood ratio test (LRT), the Wald test and other robust versions based on the MLVC method. We calculated the relative nominal inflation rate as the ratio of observed empirical type 1 error divided by the set alpha level (5, 1 and 0.1% alpha levels). MLVC tests applied to non-normal data had inflated type I errors (rate ratio greater than 1.0), which were controlled best by Box-Cox transformation and to a lesser degree by Winsorizing. For example, for non-transformed, skewed phenotypes (derived from a chi2 distribution with 2 degrees of freedom), the rates of empirical type 1 error with respect to set alpha level=0.01 were 0.80, 4.35 and 7.33 for the original H-E test, LRT and Wald test, respectively. For the same alpha level=0.01, these rates were 1.12, 3.095 and 4.088 after Winsorizing and 0.723, 1.195 and 1.905 after Box-Cox transformation. Winsorizing reduced inflated error rates for the leptokurtic distribution (derived from a Laplace distribution with mean 0 and variance 8). Further, power (adjusted for empirical type 1 error) at the 0.01 alpha level ranged from 4.7 to 17.3% across all tests

  18. EFFECT OF SODIUM HYDROXIDE CONCENTRATION ON FRESH PROPERTIES AND COMPRESSIVE STRENGTH OF SELF-COMPACTING GEOPOLYMER CONCRETE

    Directory of Open Access Journals (Sweden)

    FAREED AHMED MEMON

    2013-02-01

    Full Text Available This paper reports the results of the laboratory tests conducted to investigate the effect of sodium hydroxide concentration on the fresh properties and compressive strength of self-compacting geopolymer concrete (SCGC. The experiments were conducted by varying the concentration of sodium hydroxide from 8 M to 14 M. Test methods such as Slump flow, V-Funnel, L-box and J-Ring were used to assess the workability characteristics of SCGC. The test specimens were cured at 70°C for a period of 48 hours and then kept in room temperature until the day of testing. Compressive strength test was carried out at the ages of 1, 3, 7 and 28 days. Test results indicate that concentration variation of sodium hydroxide had least effect on the fresh properties of SCGC. With the increase in sodium hydroxide concentration, the workability of fresh concrete was slightly reduced; however, the corresponding compressive strength was increased. Concrete samples with sodium hydroxide concentration of 12 M produced maximum compressive strength.

  19. Generating an Automated Test Suite by Variable Strength Combinatorial Testing for Web Services

    Directory of Open Access Journals (Sweden)

    Yin Li

    2016-09-01

    Full Text Available Testing Web Services has become the spotlight of software engineering as an important means to assure the quality of Web application. Due to lacking of graphic interface and source code, Web services need an automated testing method, which is an important part in efficiently designing and generating test suite. However, the existing testing methods may lead to the redundancy of test suite and the decrease of fault-detecting ability since it cannot handle scenarios where the strengths of the different interactions are not uniform. With the purpose of solving this problem, firstly the formal tree model based on WSDL is constructed and the actual interaction relationship of each node is made sufficient consideration into, then the combinatorial testing is proposed to generate variable strength combinatorial test suite based on One-test-at-a-time strategy. At last test cases are minimized according to constraint rules. The results show that compared with conventional random testing, the proposed approach can detect more errors with the same amount of test cases which turning out to be more ideal than existing ones in size.

  20. Problems in Standardization of Orthodontic Shear Bond Strength Tests; A Brief Review

    Directory of Open Access Journals (Sweden)

    M.S. A. Akhoundi

    2005-03-01

    Full Text Available Bonding brackets to the enamel surface has gained much popularity today. New adhesive systems have been introduced and marketed and a considerable increase in research regarding bond strength has been published. A considerable amount of these studies deal with shear bond strength of adhesives designed for orthodontic purpose.Previous studies have used variety of test designs. This diversity in test design is due to the fact that there is no standard method for evaluating shear bond strength in orthodontics. Therefore comparison of data obtained from different study is almost impossible.This article tries to briefly discuss the developments occurred in the process of shear bond strength measurement of orthodontic adhesives with an emphasis on the type of test set up and load application.Although the test designs for measuring shear bond strength in orthodontics are still far from ideal, attempts must be made to standardize these tests especially in order to makecomparison of different data easier. It is recommended that test designs be set up in such a manner that better matches with the purpose of the study.

  1. Testing compression strength of wood logs by drilling resistance

    Science.gov (United States)

    Kalny, Gerda; Rados, Kristijan; Rauch, Hans Peter

    2017-04-01

    Soil bioengineering is a construction technique using biological components for hydraulic and civil engineering solutions, based on the application of living plants and other auxiliary materials including among others log wood. Considering the reliability of the construction it is important to know about the durability and the degradation process of the wooden logs to estimate and retain the integral performance of a soil bioengineering system. An important performance indicator is the compression strength, but this parameter is not easy to examine by non-destructive methods. The Rinntech Resistograph is an instrument to measure the drilling resistance by a 3 mm wide needle in a wooden log. It is a quasi-non-destructive method as the remaining hole has no weakening effects to the wood. This is an easy procedure but result in values, hard to interpret. To assign drilling resistance values to specific compression strengths, wooden specimens were tested in an experiment and analysed with the Resistograph. Afterwards compression tests were done at the same specimens. This should allow an easier interpretation of drilling resistance curves in future. For detailed analyses specimens were investigated by means of branch inclusions, cracks and distances between annual rings. Wood specimens are tested perpendicular to the grain. First results show a correlation between drilling resistance and compression strength by using the mean drilling resistance, average width of the annual rings and the mean range of the minima and maxima values as factors for the drilling resistance. The extended limit of proportionality, the offset yield strength and the maximum strength were taken as parameters for compression strength. Further investigations at a second point in time strengthen these results.

  2. Reliability of nondestructive testing of metal strength properties for power equipment

    International Nuclear Information System (INIS)

    Bugaj, N.V.; Lebedev, A.A.; Sharko, A.V.

    1985-01-01

    Ultrasonic control which is a constituent part of a complex control system which includes specimen-free (by hardness) tests, random breaking tests and acoustic measurements is stUdied for its reliability with respect to strength properties of power-equipment metal. Quantitative and alternative criteria are developed to estimate quality of elements for power-equipment according to results of metal strength properties. Acoustic control results are presented for ultimate strength in 12Kh1MF-steel

  3. Practicing the Test Produces Strength Equivalent to Higher Volume Training.

    Science.gov (United States)

    Mattocks, Kevin T; Buckner, Samuel L; Jessee, Matthew B; Dankel, Scott J; Mouser, J Grant; Loenneke, Jeremy P

    2017-09-01

    To determine if muscle growth is important for increasing muscle strength or if changes in strength can be entirely explained from practicing the strength test. Thirty-eight untrained individuals performed knee extension and chest press exercise for 8 wk. Individuals were randomly assigned to either a high-volume training group (HYPER) or a group just performing the one repetition maximum (1RM) strength test (TEST). The HYPER group performed four sets to volitional failure (~8RM-12RM), whereas the TEST group performed up to five attempts to lift as much weight as possible one time each visit. Data are presented as mean (90% confidence interval). The change in muscle size was greater in the HYPER group for both the upper and lower bodies at most but not all sites. The change in 1RM strength for both the upper body (difference of -1.1 [-4.8, 2.4] kg) and lower body (difference of 1.0 [-0.7, 2.8] kg for dominant leg) was not different between groups (similar for nondominant). Changes in isometric and isokinetic torque were not different between groups. The HYPER group observed a greater change in muscular endurance (difference of 2 [1,4] repetitions) only in the dominant leg. There were no differences in the change between groups in upper body endurance. There were between-group differences for exercise volume (mean [95% confidence interval]) of the dominant (difference of 11,049.3 [9254.6-12,844.0] kg) leg (similar for nondominant) and chest press with the HYPER group completing significantly more total volume (difference of 13259.9 [9632.0-16,887.8] kg). These findings suggest that neither exercise volume nor the change in muscle size from training contributed to greater strength gains compared with just practicing the test.

  4. A Novel Image Encryption Based on Algebraic S-box and Arnold Transform

    Science.gov (United States)

    Farwa, Shabieh; Muhammad, Nazeer; Shah, Tariq; Ahmad, Sohail

    2017-09-01

    Recent study shows that substitution box (S-box) only cannot be reliably used in image encryption techniques. We, in this paper, propose a novel and secure image encryption scheme that utilizes the combined effect of an algebraic substitution box along with the scrambling effect of the Arnold transform. The underlying algorithm involves the application of S-box, which is the most imperative source to create confusion and diffusion in the data. The speciality of the proposed algorithm lies, firstly, in the high sensitivity of our S-box to the choice of the initial conditions which makes this S-box stronger than the chaos-based S-boxes as it saves computational labour by deploying a comparatively simple and direct approach based on the algebraic structure of the multiplicative cyclic group of the Galois field. Secondly the proposed method becomes more secure by considering a combination of S-box with certain number of iterations of the Arnold transform. The strength of the S-box is examined in terms of various performance indices such as nonlinearity, strict avalanche criterion, bit independence criterion, linear and differential approximation probabilities etc. We prove through the most significant techniques used for the statistical analyses of the encrypted image that our image encryption algorithm satisfies all the necessary criteria to be usefully and reliably implemented in image encryption applications.

  5. Correlation-induced suppression of decoherence in capacitively coupled Cooper-pair boxes

    Science.gov (United States)

    Hu, Xuedong; You, J. Q.; Nori, Franco

    2005-03-01

    Charge fluctuations from gate bias and background traps severely limit the performance of a charge qubit in a Cooper-pair box (CPB). Here we discuss an encoding approachootnotetextJ.Q. You, X.Hu, and F. Nori, cond-mat/0407423. to control the decoherence effects of these charge fluctuations using two strongly capacitively coupled CPBs. This coupled-box system has a low-decoherence subspace of two states, for which we calculate the dephasing and relaxation rates using a master equation approach. Our results show that the inter-box Coulomb correlation can significantly suppress decoherence of this two-level system by reducing the strength of the system-environment interaction, making it a promising candidate as a logical qubit, encoded using two CPBs.

  6. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain

    DEFF Research Database (Denmark)

    Rafn, Bolette S; Tang, Lars; Nielsen, Peter Martin

    2016-01-01

    OBJECTIVE: To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. DESIGN: Cross-sectional study. SETTING: Clinical assessments at Sports Orthopaedic Research...... Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. PARTICIPANTS: Twenty-four male soccer players with unilateral long-standing hip and groin pain. INTERVENTIONS: The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion...... strength (Spearman rho = -0.44, P = 0.016). CONCLUSIONS: Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain....

  7. Intra-tester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.

    Science.gov (United States)

    Brindle, Richard A; Ebaugh, D David; Milner, Clare E

    2017-11-15

    Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a 'break' test the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower. To determine intra-rater reliability and construct validity of a hip abductor eccentric strength test. Intra-rater reliability and construct validity study. Twenty healthy adults (26 ±6 years; 1.66 ±0.06 m; 62.2 ±8.0 kg) made two visits to the laboratory at least one week apart. During the hip abductor eccentric strength test, a hand-held dynamometer recorded peak force and time to peak force and limb position was recorded via a motion capture system. Intra-rater reliability was determined using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable difference (MDD). Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a one-sample t-test. The hip abductor eccentric strength test had substantial intra-rater reliability (ICC( 3,3 ) = 0.88; 95% confidence interval: 0.65-0.95), SEM of 0.9%BWh, and a MDD of 2.5%BWh. Construct validity was established as peak force occurred 2.1s (±0.6s; range 0.7s to 3.7s) after the start of the lowering phase of the test (p ≤ 0.001). The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.

  8. Finite Element Simulation of Diametral Strength Test of Hydroxyapatite

    International Nuclear Information System (INIS)

    Ozturk, Fahrettin; Toros, Serkan; Evis, Zafer

    2011-01-01

    In this study, the diametral strength test of sintered hydroxyapatite was simulated by the finite element software, ABAQUS/Standard. Stress distributions on diametral test sample were determined. The effect of sintering temperature on stress distribution of hydroxyapatite was studied. It was concluded that high sintering temperatures did not reduce the stress on hydroxyapatite. It had a negative effect on stress distribution of hydroxyapatite after 1300 deg. C. In addition to the porosity, other factors (sintering temperature, presence of phases and the degree of crystallinity) affect the diametral strength of the hydroxyapatite.

  9. Assessment of strength characteristics of Al2024 ECAP metal using small punch testing

    International Nuclear Information System (INIS)

    Ma, Young Wha; Choi, Jeong Woo; Yoon, Kee Bong; Kim, Seon Hwa

    2006-01-01

    When subjected to severe shear deformation by ECAP, microstructure of Al2024 becomes extremely refined. To measure the strength of that, Small Punch(SP) testing method was adopted as a substitute for the conventional uniaxial tensile testing because the size of material processed by ECAP were limited to ψ12 mm in transverse direction. SP tests were performed with specimens in longitudinal and transverse directions of Al2024 ECAP metal. For comparing the strength values with those assessed by SP tests, uniaxial tensile tests were also conducted with specimens in longitudinal direction. Failure surfaces of the tested SP specimens showed that failure mode was shear deformation and Al2024 ECAP metal has an anisotropy in strength. Thus, conventional equations proposed for assessing the strength characteristics were improper to assess those of Al2024 ECAP metal. In this paper a way of assessing the strength of Al2024 ECAP metal was proposed and was proven to be effective

  10. Boxing training for patients with Parkinson disease: a case series.

    Science.gov (United States)

    Combs, Stephanie A; Diehl, M Dyer; Staples, William H; Conn, Lindsay; Davis, Kendra; Lewis, Nicole; Schaneman, Katie

    2011-01-01

    A nontraditional form of exercise recently applied for patients with Parkinson disease (PD) is boxing training. The primary purpose of this case series is to describe the effects of disease severity and duration of boxing training (short term and long term) on changes in balance, mobility, and quality of life for patients with mild or moderate to severe PD. The feasibility and safety of the boxing training program also were assessed. Six patients with idiopathic PD attended 24 to 36 boxing training sessions for 12 weeks, with the option of continuing the training for an additional 24 weeks (a seventh patient attended sessions for only 4 weeks). The 90-minute sessions included boxing drills and traditional stretching, strengthening, and endurance exercises. Outcomes were tested at the baseline and after 12, 24, and 36 weeks of boxing sessions (12-, 24-, and 36-week tests). The outcome measures were the Functional Reach Test, Berg Balance Scale, Activities-specific Balance Confidence Scale, Timed "Up & Go" Test, Six-Minute Walk Test, gait speed, cadence, stride length, step width, activities of daily living and motor examination subscales of the Unified Parkinson Disease Rating Scale, and Parkinson Disease Quality of Life Scale. Six patients completed all phases of the case series, showed improvements on at least 5 of the 12 outcome measures over the baseline at the 12-week test, and showed continued improvements at the 24- and 36-week tests. Patients with mild PD typically showed improvements earlier than those with moderate to severe PD. Despite the progressive nature of PD, the patients in this case series showed short-term and long-term improvements in balance, gait, activities of daily living, and quality of life after the boxing training program. A longer duration of training was necessary for patients with moderate to severe PD to show maximal training outcomes. The boxing training program was feasible and safe for these patients with PD.

  11. Comparison of hydroxyapatite and dental enamel for testing shear bond strengths.

    Science.gov (United States)

    Imthiaz, Nishat; Georgiou, George; Moles, David R; Jones, Steven P

    2008-05-01

    To investigate the feasibility of using artificial hydroxyapatite as a future biomimetic laboratory substitute for human enamel in orthodontic bond strength testing by comparing the shear bond strengths and nature of failure of brackets bonded to samples of hydroxyapatite and enamel. One hundred and fifty hydroxyapatite discs were prepared by compression at 20 tons and fired in a furnace at 1300 degrees C. One hundred and five enamel samples were prepared from the buccal and palatal/lingual surfaces of healthy premolars extracted for orthodontic purposes. Orthodontic brackets were bonded to each sample and these were subjected to shear bond strength testing using a custom-made jig mounted in an Instron Universal Testing Machine. The force value at bond failure was obtained, together with the nature of failure which was assessed using the Adhesive Remnant Index. The mean shear bond strength for the enamel samples was 16.62 MPa (95 per cent CI: 15.26, 17.98) and for the hydroxyapatite samples 20.83 MPa (95 per cent CI: 19.68, 21.98). The difference between the two samples was statistically significant (p enamel samples scored 2 or 3, while 49 per cent of the hydroxyapatite samples scored 0 or 1. Hydroxyapatite was an effective biomimetic substrate for bond strength testing with a mean shear bond strength value (20.83 MPa) at the upper end of the normal range attributed to enamel (15-20 MPa). Although the difference between the shear bond strengths for hydroxyapatite and enamel was statistically significant, hydroxyapatite could be used as an alternative to enamel for comparative laboratory studies until a closer alternative is found. This would eliminate the need for extracted teeth to be collected. However, it should be used with caution for quantitative studies where true bond strengths are to be investigated.

  12. Qualification of box HEPA filters for nuclear applications

    International Nuclear Information System (INIS)

    Bergman, W.; Larsen, G.; Wilson, K.; Rainer, F.

    1995-03-01

    We have successfully completed qualification tests on high efficiency particulate air (HEPA) filters that are encapsulated within a box and manufactured by American Air Filters. The qualification tests are required by the American Society of Mechanical Engineers Standard ASME N509 and the U.S. Military Standard MIL-F-51068 for HEPA filters to be used in nuclear applications. The qualification tests specify minimum filter efficiencies following exposure to heated air, overpressure, and rough handling. Prior to this study, no box HEPA filters from any manufacturer had been qualified despite their wide-spread use in Department of Energy (DOE) facilities. Box HEPA filters are not addressed in any of the existing HEPA standards and only briefly discussed in the Nuclear Air Cleaning Handbook

  13. [Influence of retainer design on fixation strength of resin-bonded glass fiber reinforced composite fixed cantilever dentures].

    Science.gov (United States)

    Petrikas, O A; Voroshilin, Iu G; Petrikas, I V

    2013-01-01

    Fiber-reinforced composite (FRC) fixed partial dentures (FPD) have become an accepted part of the restorative dentist's armamentarium. The aim of this study was to evaluate in vitro the influence of retainer design on the strength of two-unit cantilever resin-bonded glass FRC-FPDs. Four retainer designs were tested: a dual wing, a dual wing + horizontal groove, a dual wing + occlusal rest and a step-box. Of each design on 7 human mandibular molars, FRC-FPDs of a premolar size were produced. The FRC framework was made of resin Revolution (Kerr) impregnated glass fibers (GlasSpan, GlasSpan) and veneered with hybrid resin composite (Charisma, Kulzer). Revolution (Kerr) was used as resin luting cement. FRC-FPDs were loaded to failure in a universal testing machine. T (Student's)-test was used to evaluate the data. The four designs were analyzed with finite element analysis (FEA) to reveal the stress distribution within the tooth/restoration complex. Significantly lower fracture strengths were observed with inlay-retained FPDs (step-box: 172±11 N) compared to wing-retained FPDs (poptimal design for replacement of a single premolar by means of a two-unit cantilever FRC-FPDs.

  14. Determination of strength behaviour of slope supported by vegetated crib walls using centrifuge model testing

    Science.gov (United States)

    Sudan Acharya, Madhu

    2010-05-01

    The crib retaining structures made of wooden/bamboo logs with live plants inside are called vegetative crib walls which are now becoming popular due to their advantages over conventional civil engineering walls. Conventionally, wooden crib walls were dimensioned based on past experiences. At present, there are several guidelines and design standards for machine finished wooden crib walls, but only few guidelines for the design and construction of vegetative log crib walls are available which are generally not sufficient for an economic engineering design of such walls. Analytical methods are generally used to determine the strength of vegetated crib retaining walls. The crib construction is analysed statically by satisfying the condition of static equilibrium with acceptable level of safety. The crib wall system is checked for internal and external stability using conventional monolithic and silo theories. Due to limitations of available theories, the exact calculation of the strength of vegetated wooden/bamboo crib wall cannot be made in static calculation. Therefore, experimental measurements are generally done to verify the static analysis. In this work, a model crib construction (1:20) made of bamboo elements is tested in the centrifuge machine to determine the strength behaviour of the slope supported by vegetated crib retaining wall. A geotechnical centrifuge is used to conduct model tests to study geotechnical problems such as the strength, stiffness and bearing capacity of different structures, settlement of embankments, stability of slopes, earth retaining structures etc. Centrifuge model testing is particularly well suited to modelling geotechnical events because the increase in gravitational force creates stresses in the model that are equivalent to the much larger prototype and hence ensures that the mechanisms of ground movements observed in the tests are realistic. Centrifuge model testing provides data to improve our understanding of basic mechanisms

  15. Comparison of Shear Strength Properties for Undisturbed and Reconstituted Parit Nipah Peat, Johor

    Science.gov (United States)

    Azhar, A. T. S.; Norhaliza, W.; Ismail, B.; Abdullah, M. E.; Zakaria, M. N.

    2016-11-01

    Shear strength of soil is required to determine the soil stability and design the foundations. Peat is known as a soil with complex natural formations which also contributes problems to the researchers, developers, engineers and contractors in constructions and infrastructures. Most researchers conducted experiment and investigation of shear strength on peat using shear box test and simple shear test, but only a few had discovered the behavior of peat using triaxial consolidated undrained test. The aim of this paper is to determine the undrained shear strength properties of reconstituted peat and undisturbed peat of Parit Nipah, Johor for comparison purposes. All the reconstituted peat samples were formed with the size that passed opening sieve 3.35 mm and preconsolidation pressure at 100 kPa. The result of undrained shear strength of reconstituted peat was 21kPa for cohesion with the angle of friction, 41° compare to the undisturbed peat with cohesion 10 kPa and angle of friction, 16°. The undrained shear strength properties result obtained shows that the reconstituted peat has higher strength than undisturbed peat. For relationship deviator stress-strain, σd max and excess pore pressure, Δu, it shows that both of undisturbed and reconstituted gradually increased when σ’ increased, but at the end of the test, the values are slightly dropped. The physical properties of undisturbed and reconstituted peat were also investigated to correlate with the undrained shear strength results.

  16. Optimization of the box-girder of overhead crane with constrained ...

    African Journals Online (AJOL)

    Keywords: Overhead crane - Box-girder - New bat algorithm - level of comparison - Higher strength steel. Optimisation de poutre caisson de pont roulant avec un nouvel algorithme de chauve souris sous contrainte. Une conception optimale pour un poids minimal de la poutre principale d'un pont roulant peut réduire ...

  17. Duration dependence test for rational speculative bubble: the strength and weakness

    OpenAIRE

    Ahmad, Mahyudin

    2012-01-01

    This review highlights the strength and weakness of duration dependence test used by Mokhtar, Nassir and Hassan (2006) to detect the rational speculative bubble in the Malaysian stock market. It is found that despite the test’s strength over the other tests, it is however sensitive to different specifications and therefore may produce contrasting results.

  18. Tests of Hadronic Probes of GT Strength

    CERN Multimedia

    2002-01-01

    There are many important problems where one wishes to know the distribution of Gamow-Teller (GT) strength in circumstances where it cannot be measured directly (for example, because of energy-release limitations). Then one must rely on hadronic probes to infer the GT strength. It is therefore essential to test these probes as extensively as possible. The isospin-analog transitions in $^{37}$Ca $\\beta^{+}$ -decay and $^{37}$Cl$(p, n)$ provide an excellent ground for such a test. Recent $^{37}$Cl$ (p, n) $ studies, while qualitatively in agreement with our previous ISOLDE work on $^{37}$Ca $\\beta^{+} $ -decay, show quantitative discrepancies that appear to grow as the excitation energy in the residual nuclei increases. Because of the bulk of the GT strengh appears at these high excitation energies, it is important to extend the $\\beta$-decay data to even higher excitation energies where, because of rapidly diminishing phase-space, strong GT transitions correspond to very weak $\\beta$ -branches. We propose to do...

  19. Standard test method for compressive (crushing) strength of fired whiteware materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers two test procedures (A and B) for the determination of the compressive strength of fired whiteware materials. 1.2 Procedure A is generally applicable to whiteware products of low- to moderately high-strength levels (up to 150 000 psi or 1030 MPa). 1.3 Procedure B is specifically devised for testing of high-strength ceramics (over 100 000 psi or 690 MPa). 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Box-Cox Test: the theoretical justification and US-China empirical study

    Directory of Open Access Journals (Sweden)

    Tam Bang Vu

    2011-01-01

    Full Text Available In econometrics, the derivation of a theoretical model leads sometimes to two econometric models, which can be considered justified based on their respective approximation approaches. Hence, the decision of choosing one between the two hinges on applied econometric tools. In this paper, the authors develop a theoretical econometrics consumer maximization model to measure the flow of durables’ expenditures where depreciation is added to former classical econometrics model. The proposed model was formulated in both linear and logarithmic forms. Box-Cox tests were used to choose the most appropriate one among them. The proposed model was then applied to the historical data from the U.S. and China for a comparative study and the results discussed.

  1. Comparison of Weibull strength parameters from flexure and spin tests of brittle materials

    Science.gov (United States)

    Holland, Frederic A., Jr.; Zaretsky, Erwin V.

    1991-01-01

    Fracture data from five series of four point bend tests of beam and spin tests of flat annular disks were reanalyzed. Silicon nitride and graphite were the test materials. The experimental fracture strengths of the disks were compared with the predicted strengths based on both volume flaw and surface flaw analyses of four point bend data. Volume flaw analysis resulted in a better correlation between disks and beams in three of the five test series than did surface flaw analysis. The Weibull (moduli) and characteristic gage strengths for the disks and beams were also compared. Differences in the experimental Weibull slopes were not statistically significant. It was shown that results from the beam tests can predict the fracture strength of rotating disks.

  2. High power tests of X-band RF windows at KEK

    Energy Technology Data Exchange (ETDEWEB)

    Otake, Yuji [Earthquake Research Inst., Tokyo Univ., Tokyo (Japan); Tokumoto, Shuichi; Kazakov, Sergei Yu.; Odagiri, Junichi; Mizuno, Hajime

    1997-04-01

    Various RF windows comprising a short pill-box, a long pill-box, a TW (traveling wave)-mode and three TE11-mode horn types have been developed for an X-band high-power pulse klystron with two output windows for JLC (Japan Linear Collider). The output RF power of the klystron is designed to be 130 MW with the 800 ns pulse duration. Since this X-band klystron has two output windows, the maximum RF power of the window must be over 85 MW. The design principle for the windows is to reduce the RF-power density and/or the electric-field strength at the ceramic part compared with that of an ordinary pill-box-type window. Their reduction is effective to increase the handling RF power of the window. To confirm that the difference among the electric-field strengths depends on their RF structures, High-power tests of the above-mentioned windows were successfully carried out using a traveling-wave resonator (TWR) for the horns and the TW-mode type and, installing them directly to klystron output waveguides for the short and long pill-box type. Based upon the operation experience of S-band windows, two kinds of ceramic materials were used for these tests. The TE11-mode 1/2{lambda}g-1 window was tested up to the RF peak-power of 84 MW with the 700 ns pulse duration in the TWR. (J.P.N)

  3. Wide Panel Testing Technique for Evaluating Repair Weld Strengths

    Science.gov (United States)

    Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.

    1998-01-01

    This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.

  4. Reliability of the Handgrip Strength Test in Elderly Subjects With Parkinson Disease.

    Science.gov (United States)

    Villafañe, Jorge H; Valdes, Kristin; Buraschi, Riccardo; Martinelli, Marco; Bissolotti, Luciano; Negrini, Stefano

    2016-03-01

    The handgrip strength test is widely used by clinicians; however, little has been investigated about its reliability when used in subjects with Parkinson disease (PD). The purpose of this study was to investigate the test-retest reliability of the handgrip strength test for subjects with PD. The PD group consisted of 15 patients, and the control group consisted of 15 healthy subjects. Each patient performed 3 pain-free maximal isometric contractions on each hand on 2 occasions, 1 week apart. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and 95% limits of agreement (LOA) were calculated. The 2-way analysis of variance (ANOVA) was conducted to determine the differences between sides and groups. Test-retest reliability of measurements of grip strength was excellent for dominant (ICC = 0.97; P = .001) and non-dominant (ICC = 0.98; P = .001) hand of participant with PD and (ICC = 0.99; P = .001) and (ICC = 0.99; P = .001) respectively, of healthy group. The Jamar hand dynamometer had fair to excellent test-retest reliability to test grip strength in participants with PD.

  5. Shear Strength Measurement Benchmarking Tests for K Basin Sludge Simulants

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Carolyn A.; Daniel, Richard C.; Enderlin, Carl W.; Luna, Maria; Schmidt, Andrew J.

    2009-06-10

    Equipment development and demonstration testing for sludge retrieval is being conducted by the K Basin Sludge Treatment Project (STP) at the MASF (Maintenance and Storage Facility) using sludge simulants. In testing performed at the Pacific Northwest National Laboratory (under contract with the CH2M Hill Plateau Remediation Company), the performance of the Geovane instrument was successfully benchmarked against the M5 Haake rheometer using a series of simulants with shear strengths (τ) ranging from about 700 to 22,000 Pa (shaft corrected). Operating steps for obtaining consistent shear strength measurements with the Geovane instrument during the benchmark testing were refined and documented.

  6. Decontamination and dismantling of large plutonium-contamined glove boxes

    International Nuclear Information System (INIS)

    Draulans, J.

    1991-01-01

    This report describes the work performed in the frame of two C.E.C. - Contracts FI1D-002400-B Decommissioning of very large glove boxes and FI1D-0058 Decommissioning of a complex glove box structure to be dismounted partially on place. Detailed information is given about each glove box. The selection of the solution Transportation of the glove boxes to a specialized dismantling plant is justified. The necessary contacts inside the BELGONUCLEAIRE MOX plant and between the latter and other organizations are explained. The problems of manipulating large gloves are listed and the retained solution of building a so called Stiffening frame around each glove box is described. Furthermore information is given concerning required operators time for cleaning, manipulating, packing and dismantling together with received doses and quantities of waste produced. Concerning the glove box unit partially to be dismounted on place, detailed information is given about the way the glove boxes have been treated prior to this partial dismantling on place and about the way this partial dismantling has been performed. From these results one can conclude that such a delicate task can be performed without major difficulties. Finally information is given of the decontamination test of a highly Pu contaminated glove box with freon with rather poor results and of the preliminary CO 2 blasting tests on non active samples

  7. Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

    Science.gov (United States)

    Laughlin, Mitzi S.; Lee, Stuart M. C.; Loehr, James A.; Amonette, William E.

    2009-01-01

    To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

  8. Criterion-Related Validity of a Simple Muscle Strength Test to Assess Whole Body Muscle Strength in Chinese Children Aged 10 to 12 Years.

    Science.gov (United States)

    Yin, Liqin; Tang, Changfa; Tao, Xia

    2018-01-01

    To study the criterion-related validity of simple muscle strength test (SMST) indicators and assess whole body muscle strength in Chinese children aged 10 to 12 years old. Two hundred and forty children were equally divided into four groups in different genders and residences. The SMST indicators (hand-grip, knee bent push-up, back muscle strength, sit-up, leg muscle strength, and standing long jump) were tested. We set up the total level of the whole-body muscle strength ( F total ) through testing isokinetic muscle strength of the six joints' flexion and extension movements. Pearson correlation analyses were used to analyze the correlation between the SMST indicators and the F total . (1) Leg muscle strength and back muscle strength demonstrated the highest validity scores. Sit-ups, hand grip, and standing long jump demonstrated the lowest validity scores. (2) Leg muscle strength had the highest validity for males, but back muscle strength had the highest validity for females. Back muscle strength and leg muscle strength can give the highest validity of assessing whole body muscle strength, and also has higher validity in both the urban and rural children. For urban children, but not rural, the knee bent push-up also has a high validity indicator.

  9. Criterion-Related Validity of a Simple Muscle Strength Test to Assess Whole Body Muscle Strength in Chinese Children Aged 10 to 12 Years

    Directory of Open Access Journals (Sweden)

    Liqin Yin

    2018-01-01

    Full Text Available Objective. To study the criterion-related validity of simple muscle strength test (SMST indicators and assess whole body muscle strength in Chinese children aged 10 to 12 years old. Methods. Two hundred and forty children were equally divided into four groups in different genders and residences. The SMST indicators (hand-grip, knee bent push-up, back muscle strength, sit-up, leg muscle strength, and standing long jump were tested. We set up the total level of the whole-body muscle strength (Ftotal through testing isokinetic muscle strength of the six joints’ flexion and extension movements. Pearson correlation analyses were used to analyze the correlation between the SMST indicators and the Ftotal. Results. (1 Leg muscle strength and back muscle strength demonstrated the highest validity scores. Sit-ups, hand grip, and standing long jump demonstrated the lowest validity scores. (2 Leg muscle strength had the highest validity for males, but back muscle strength had the highest validity for females. Conclusions. Back muscle strength and leg muscle strength can give the highest validity of assessing whole body muscle strength, and also has higher validity in both the urban and rural children. For urban children, but not rural, the knee bent push-up also has a high validity indicator.

  10. Virtual Box

    DEFF Research Database (Denmark)

    Davis, Hilary; Skov, Mikael B.; Stougaard, Malthe

    2007-01-01

    . This paper reports on the design, implementation and initial evaluation of Virtual Box. Virtual Box attempts to create a physical and engaging context in order to support reciprocal interactions with expressive content. An implemented version of Virtual Box is evaluated in a location-aware environment...

  11. Observations in the statistical analysis of NBG-18 nuclear graphite strength tests

    International Nuclear Information System (INIS)

    Hindley, Michael P.; Mitchell, Mark N.; Blaine, Deborah C.; Groenwold, Albert A.

    2012-01-01

    Highlights: ► Statistical analysis of NBG-18 nuclear graphite strength test. ► A Weibull distribution and normal distribution is tested for all data. ► A Bimodal distribution in the CS data is confirmed. ► The CS data set has the lowest variance. ► A Combined data set is formed and has Weibull distribution. - Abstract: The purpose of this paper is to report on the selection of a statistical distribution chosen to represent the experimental material strength of NBG-18 nuclear graphite. Three large sets of samples were tested during the material characterisation of the Pebble Bed Modular Reactor and Core Structure Ceramics materials. These sets of samples are tensile strength, flexural strength and compressive strength (CS) measurements. A relevant statistical fit is determined and the goodness of fit is also evaluated for each data set. The data sets are also normalised for ease of comparison, and combined into one representative data set. The validity of this approach is demonstrated. A second failure mode distribution is found on the CS test data. Identifying this failure mode supports the similar observations made in the past. The success of fitting the Weibull distribution through the normalised data sets allows us to improve the basis for the estimates of the variability. This could also imply that the variability on the graphite strength for the different strength measures is based on the same flaw distribution and thus a property of the material.

  12. In-vitro orthodontic bond strength testing : A systematic review and meta-analysis

    NARCIS (Netherlands)

    Finnema, K.J.; Ozcan, M.; Post, W.J.; Ren, Y.J.; Dijkstra, P.U.

    INTRODUCTION: The aims of this study were to systematically review the available literature regarding in-vitro orthodontic shear bond strength testing and to analyze the influence of test conditions on bond strength. METHODS: Our data sources were Embase and Medline. Relevant studies were selected

  13. Associations of maximal strength and muscular endurance test scores with cardiorespiratory fitness and body composition.

    Science.gov (United States)

    Vaara, Jani P; Kyröläinen, Heikki; Niemi, Jaakko; Ohrankämmen, Olli; Häkkinen, Arja; Kocay, Sheila; Häkkinen, Keijo

    2012-08-01

    The purpose of the present study was to assess the relationships between maximal strength and muscular endurance test scores additionally to previously widely studied measures of body composition and maximal aerobic capacity. 846 young men (25.5 ± 5.0 yrs) participated in the study. Maximal strength was measured using isometric bench press, leg extension and grip strength. Muscular endurance tests consisted of push-ups, sit-ups and repeated squats. An indirect graded cycle ergometer test was used to estimate maximal aerobic capacity (V(O2)max). Body composition was determined with bioelectrical impedance. Moreover, waist circumference (WC) and height were measured and body mass index (BMI) calculated. Maximal bench press was positively correlated with push-ups (r = 0.61, p strength (r = 0.34, p strength correlated positively (r = 0.36-0.44, p test scores were related to maximal aerobic capacity and body fat content, while fat free mass was associated with maximal strength test scores and thus is a major determinant for maximal strength. A contributive role of maximal strength to muscular endurance tests could be identified for the upper, but not the lower extremities. These findings suggest that push-up test is not only indicative of body fat content and maximal aerobic capacity but also maximal strength of upper body, whereas repeated squat test is mainly indicative of body fat content and maximal aerobic capacity, but not maximal strength of lower extremities.

  14. Use of combined destructive and non-destructive test methods to assess the strength of concrete

    Energy Technology Data Exchange (ETDEWEB)

    Arioz, O. [Optimizing Consultancy, Izmir (Turkey); Kilinc, K. [Kirklareli University, Department of Civil Engineering, Kirklareli (Turkey); Ramyar, K. [Ege University, Department of Civil Engineering, Ismir (Turkey); Tuncan, M.; Tuncan, A. [Anadolu University, Department of Civil Engineering, Eskişehir (Turkey)

    2013-07-01

    The compressive strength test applied on standard samples is one of the most important tests indicating the quality of concrete in structures. The results of the standard tests are compared with the values used in design calculations and the quality of concrete is controlled. Although the standard tests are well accepted by the construction industry, they may not represent the in-situ strength of concrete due to the differences between the degree of compaction and curing conditions of concrete and those of standard samples. In-situ strength is also important for the efficient planning of the construction works in huge projects. In the present study, the results obtained from standard tests, core tests, ultrasonic pulse velocity tests, and rebound hammer tests were extensively analysed for the assessment of concrete strength. Key words: Concrete strength, standard tests, core test, ultrasonic pulse velocity, rebound number.

  15. The role of self-control strength in the development of state anxiety in test situations.

    Science.gov (United States)

    Englert, C; Bertrams, A

    2013-06-01

    Self-control strength may affect state anxiety because emotion regulation is impaired in individuals whose self-control strength has been temporarily depleted. Increases in state anxiety were expected to be larger for participants with depleted compared to nondepleted self-control strength, and trait test anxiety should predict increases in state anxiety more strongly if self-control strength is depleted. In a sample of 76 university students, trait test anxiety was assessed, self-control strength experimentally manipulated, and state anxiety measured before and after the announcement of a test. State anxiety increased after the announcement. Trait test anxiety predicted increases in state anxiety only in students with depleted self-control strength, suggesting that increased self-control strength may be useful for coping with anxiety.

  16. Testing the Box-Cox Parameter for an Integrated Process

    NARCIS (Netherlands)

    J. Huang (Jian); M. Kobayashi (Masahito); M.J. McAleer (Michael)

    2011-01-01

    textabstractThis paper analyses the constant elasticity of volatility (CEV) model suggested by Chan et al. (1992). The CEV model without mean reversion is shown to be the inverse Box-Cox transformation of integrated processes asymptotically. It is demonstrated that the maximum likelihood estimator

  17. 3D modelling of the flow of self-compacting concrete with or without steel fibres. Part II: L-box test and the assessment of fibre reorientation during the flow

    Science.gov (United States)

    Deeb, R.; Kulasegaram, S.; Karihaloo, B. L.

    2014-12-01

    The three-dimensional Lagrangian particle-based smooth particle hydrodynamics method described in Part I of this two-part paper is used to simulate the flow of self-compacting concrete (SCC) with and without steel fibres in the L-box configuration. As in Part I, the simulation of the SCC mixes without fibres emphasises the distribution of large aggregate particles of different sizes throughout the flow, whereas the simulation of high strength SCC mixes which contain steel fibres is focused on the distribution of fibres and their orientation during the flow. The capabilities of this methodology are validated by comparing the simulation results with the L-box test carried out in the laboratory. A simple method is developed to assess the reorientation and distribution of short steel fibres in self-compacting concrete mixes during the flow. The reorientation of the fibres during the flow is used to estimate the fibre orientation factor (FOF) in a cross section perpendicular to the principal direction of flow. This estimation procedure involves the number of fibres cut by the section and their inclination to the cutting plane. This is useful to determine the FOF in practical image analysis on cut sections.

  18. Standards and interdisciplinary treatment of boxing injuries of the head in professional boxing on the basis of an IBF World Championship Fight.

    Science.gov (United States)

    Dragu, Adrian; Unglaub, Frank; Radomirovic, Sinisa; Schnürer, Stefan; Wagner, Walter; Horch, Raymund E; Hell, Berthold

    2010-12-01

    Boxing injuries are well known in hobby boxing as well as in professional boxing. Especially in professional boxing it is of great importance to implement and follow prevention-, diagnosis- and therapy-standards in order to prevent or at least to minimize injuries of the athlete. The utmost aim would be to establish international prevention-, diagnosis- and therapy-standards for boxing injuries in professional boxing. However, this aim is on a short run unrealistic, as there are too many different professional boxing organisations with different regulations. A realistic short term aim would be to develop a national standard in order to unify the management and medical treatment of boxing injuries in professional boxing. We present the management and interdisciplinary treatment of a professional boxer with a bilateral open fracture of the mandible during a middle weight IBF World Championship Fight. On the basis of this case we want to present and discuss the possibilities of an interdisciplinary and successful medical treatment. In order to prevent or minimize boxing injuries of professional boxers, annual MRI-Scans of the head and neck have to be performed as prevention standard. Furthermore, neurocognitive tests must be performed on a regular basis. Boxing injuries in professional boxing need an interdisciplinary, unbiased and complex analysis directly at the boxing ring. The treatment of the injuries should be only performed in medical centres and thus under constant parameters. The needed qualifications must be learned in mandatory national licence courses of boxing physicians, referees and promoters.

  19. Secure image encryption algorithm design using a novel chaos based S-Box

    International Nuclear Information System (INIS)

    Çavuşoğlu, Ünal; Kaçar, Sezgin; Pehlivan, Ihsan; Zengin, Ahmet

    2017-01-01

    Highlights: • A new chaotic system is developed for creating S-Box and image encryption algorithm. • Chaos based random number generator is designed with the help of the new chaotic system. NIST tests are run on generated random numbers to verify randomness. • A new S-Box design algorithm is developed to create the chaos based S-Box to be utilized in encryption algorithm and performance tests are made. • The new developed S-Box based image encryption algorithm is introduced and image encryption application is carried out. • To show the quality and strong of the encryption process, security analysis are performed and compared with the AES and chaos algorithms. - Abstract: In this study, an encryption algorithm that uses chaos based S-BOX is developed for secure and speed image encryption. First of all, a new chaotic system is developed for creating S-Box and image encryption algorithm. Chaos based random number generator is designed with the help of the new chaotic system. Then, NIST tests are run on generated random numbers to verify randomness. A new S-Box design algorithm is developed to create the chaos based S-Box to be utilized in encryption algorithm and performance tests are made. As the next step, the new developed S-Box based image encryption algorithm is introduced in detail. Finally, image encryption application is carried out. To show the quality and strong of the encryption process, security analysis are performed. Proposed algorithm is compared with the AES and chaos algorithms. According to tests results, the proposed image encryption algorithm is secure and speed for image encryption application.

  20. Bond strength test of acrylic artificial teeth with prosthetic base

    Directory of Open Access Journals (Sweden)

    Erna Kurnikasari

    2008-07-01

    Full Text Available Denture consists of acrylic artificial teeth and acrylic prothesis base bond chemically with a bond strength of 315 kgF/cm2. Most of the commercial acrylic artificial teeth do not specify their specifications and all of those acrylic artificial teeth do not include mechanical data (bond strength. The aim of this study is to discover which acrylic artificial teeth meet ADA specification no. 15. This study is a descriptive analytic study performed to 5 acrylic artificial teeth posterior brands commonly used by dentists and technicians. From each brand, 3 sample teeth were taken. The acrylic artificial teeth were prepared into a rectangular shape and were attached between acrylic prothesis base simulation and jigs. The sample was given tensile load using a Universal Testing Machine. The amount of force that causes the teeth to be fractured was recorded and the bond strength was calculated. The results of the study show that the average value for the five acrylic artificial teeth for the five brands were as followed: Brand A, 125.993 kgF/cm2; B, 188.457 kgF/cm2; C, 175.880 kgF/cm2; D, 153.373 kgF/cm2; E, 82.839 kgF/cm2. The data can be tested statistically by using One Way ANOVA test and Dunnett test (alpha = 0.05. From the study, it is concluded that the five acrylic artificial teeth have a bond strength below the ADA specification no. 15.

  1. Sustainable normal and high strength recycled aggregate concretes using crushed tested cylinders as coarse aggregates

    Directory of Open Access Journals (Sweden)

    Bilal S. Hamad

    2017-12-01

    Full Text Available The paper reports on a research program that was designed at the American University of Beirut (AUB to investigate the fresh and hardened mechanical properties of a high performance concrete mix produced with partial or full substitution of crushed natural lime-stone aggregates with recycled aggregates from crushed tested cylinders in batching plants. Choosing crushed cylinders as source of recycling would result in reusing portion of the waste products of the concrete production industry. An extensive concrete batching and testing program was conducted to achieve two optimum normal and high strength concrete mixes. The variables were the nominal concrete strength (28 or 60 MPa and the percentage replacement of natural coarse aggregates with recycled aggregates from crushed tested cylinders (0, 20, 40, 60, 80, or 100%. Normal strength tested cylinders were used as source of the recycled aggregates for the normal strength concrete (NSC mix and high strength tested cylinders were used for the high strength concrete (HSC mix. Tests on the trial batches included plastic state slump and hardened state mechanical properties including cylinder compressive strength, cylinder splitting tensile strength, modulus of elasticity, and standard beams flexural strength. The results indicated no significant effect on the slump and around 10% average reduction in the hardened mechanical properties for both investigated levels of concrete compressive strength.

  2. Acceptance test for the linear motion actuator for the scanning slit of the HIE-ISOLDE short diagnostic boxes

    CERN Document Server

    Cantero, E D; Bravin, E; Sosa, A

    2014-01-01

    We performed experimental tests to characterize the mechanical accuracy of a linear actuator designed by the company AVS for the movement of the scanning slit of the HIE-ISOLDE short diagnostic boxes. The mechanism consists of a linear actuator composed of two guiding rods and a lead screw, with a full stroke of 135 mm. A specially designed blade was mounted on the actuator and the transverse positioning of the blade was monitored with a camera-based optical system while moving the actuator at speeds of up to 10 mm/s. The repeatability of the positioning of the blade after several cycles around predefined positions was also measured. The results of the measurements and a general inspection of the device show that the proposed solution fulfils the specifications. A full prototype of short diagnostic box for the HIE-ISOLDE project can now be built for testing.

  3. Indigenous Design for Automatic Testing of Tensile Strength Using Graphical User Interface

    OpenAIRE

    Ali Rafay; Junejo Faraz; Imtiaz Rafey; Shamsi Usama Sultan

    2016-01-01

    Tensile Testing is a fundamental material test to measure the tenacity and tensile strength. Tensile strength means ability to take tensile stress. This Universal Testing Machine is designed using Dual Cylinder Technique in order to comply with the maximun load (tensile force) with the reduction of minimum physical effort and minimized losses.It is to provide material testing opportunity to the students of different institutions, locally and globally, at lowest price; so that they can have a ...

  4. Dentin-composite bond strength measurement using the Brazilian disk test.

    Science.gov (United States)

    Carrera, Carola A; Chen, Yung-Chung; Li, Yuping; Rudney, Joel; Aparicio, Conrado; Fok, Alex

    2016-09-01

    This study presents a variant of the Brazilian disk test (BDT) for assessing the bond strength between composite resins and dentin. Dentin-composite disks (ϕ 5mm×2mm) were prepared using either Z100 or Z250 (3M ESPE) in combination with one of three adhesives, Adper Easy Bond (EB), Adper Scotchbond Multi-Purpose (MP) and Adper Single Bond (SB), and tested under diametral compression. Acoustic emission (AE) and digital image correlation (DIC) were used to monitor debonding of the composite from the dentin ring. A finite element (FE) model was created to calculate the bond strengths using the failure loads. Fracture modes were examined by scanning electron microscopy (SEM). Most specimens fractured along the dentin-resin composite interface. DIC and AE confirmed interfacial debonding immediately before fracture of the dentin ring. Results showed that the mean bond strength with EB (14.9±1.9MPa) was significantly higher than with MP (13.2±2.4MPa) or SB (12.9±3.0MPa) (p0.05). Z100 (14.5±2.3MPa) showed higher bond strength than Z250 (12.7±2.5MPa) (pstrength between dentin and composite, with zero premature failure, reduced variability in the measurements, and consistent failure at the dentin-composite interface. The new test could help to predict the clinical performance of adhesive systems more effectively and consistently by reducing the coefficient of variation in the measured bond strength. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Fracture strength testing of crowns made of CAD/CAM composite resins.

    Science.gov (United States)

    Okada, Ryota; Asakura, Masaki; Ando, Akihiro; Kumano, Hirokazu; Ban, Seiji; Kawai, Tatsushi; Takebe, Jun

    2018-03-28

    The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3kN to 3.9kN, and was similar to that of IPS (3.3kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175MPa to 247MPa, and was significantly lower than that of IPS (360MPa). All CAD/CAM composite resin crowns studied presented about 3-4 times higher fracture strength than the average maximum bite force of the molar tooth (700-900N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  6. Boxing fatalities in relation to rule changes in Japan: secondary data analysis.

    Science.gov (United States)

    Teramoto, Masaru; Cross, Chad L; Cushman, Daniel M; Willick, Stuart E

    2018-01-18

    To examine whether changing weigh-in from the same day of the match to the day before the match and prohibiting 6-oz gloves are associated with fatalities in boxing matches sanctioned by the Japan Boxing Commission (JBC). We analyzed the rates of boxing fatalities before and after the two rule changes above via secondary analysis of data. Demographics and boxing records of deceased boxers were examined using descriptive statistics, exact binomial test the Mann-Whitney-Wilcoxon test and Fisher's exact tests. As of this study, a total of 38 boxers (23.9 ± 3.3 years of age) reportedly died due to injuries sustained in JBC-sanctioned boxing matches since 1952. Changing weigh-in to the day before the match or prohibiting 6-oz gloves was not significantly associated with the rates of boxing fatalities 5 years and 10 years before and after the rule changes (p > 0.05). Deceased boxers after these rule changes were significantly older, completed significantly more rounds in the final match, and were significantly less likely to lose the previous match (prior to the final match) and to do so by knockouts (p boxing fatalities.

  7. Solar cell contact pull strength as a function of pull-test temperature

    Science.gov (United States)

    Yasui, R. K.; Berman, P. A.

    1972-01-01

    Four types of solar cell contacts were given pull-strength tests at temperatures between -173 and +165 C. Contacts tested were: (1) solder-coated titanium-silver contacts on n-p cells, (2) palladium-containing titanium-silver contacts on n-p cells, (3) titanium-silver contacts on 0.2-mm-thick n-p cells, and (4) solder-coated electroless-nickel-plated contacts on p-n cells. Maximum pull strength was demonstrated at temperatures significantly below the air mass zero cell equilibrium temperature of +60 C. At the lowest temperatures, the chief failure mechanism was silicon fracture along crystallographic planes; at the highest temperatures, it was loss of solder strength. In the intermediate temperatures, many failure mechanisms operated. Pull-strength tests give a good indication of the suitability of solar cell contact systems for space use. Procedures used to maximize the validity of the results are described.

  8. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain: What are the Clinical Implications of Pain During Testing?

    Science.gov (United States)

    Rafn, Bolette S; Tang, Lars; Nielsen, Martin P; Branci, Sonia; Hölmich, Per; Thorborg, Kristian

    2016-05-01

    To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. Cross-sectional study. Clinical assessments at Sports Orthopaedic Research Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. Twenty-four male soccer players with unilateral long-standing hip and groin pain. The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion, adduction, abduction, isometric hip flexion-modified Thomas test, and eccentric hip adduction). Muscle strength was measured with a hand-held dynamometer, and the players rated the pain during testing on a numerical rating scale (0-10). In 4 tests (isometric hip adduction, abduction, flexion, and eccentric adduction), no significant correlations were found between pain during testing and hip muscle strength (Spearman rho = -0.28 to 0.06, P = 0.09-0.39). Isometric hip flexion (modified Thomas test position) showed a moderate negative correlation between pain and hip muscle strength (Spearman rho = -0.44, P = 0.016). Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain.

  9. Strength and fatigue testing of large size wind turbines rotors. Vol. II: Full size natural vibration and static strength test, a reference case

    Energy Technology Data Exchange (ETDEWEB)

    Arias, F.; Soria, E.

    1996-12-01

    This report shows the methods and procedures selected to define a strength test for large size wind turbine, anyway in particular it application on a 500 kW blade and it results obtained in the test carried out in july of 1995 in Asinel`s test plant (Madrid). Henceforth, this project is designed in an abbreviate form whit the acronym SFAT. (Author)

  10. Strength and fatigue testing of large size wind turbines rotors. Volume II. Full size natural vibration and static strength test, a reference case

    International Nuclear Information System (INIS)

    Arias, F.; Soria, E.

    1996-01-01

    This report shows the methods and procedures selected to define a strength test for large size wind turbine, anyway in particularly it application on a 500 kW blade and it results obtained in the test carried out in july of 1995 in Asinel test plant (Madrid). Henceforth, this project is designed in an abbreviate form whit the acronym SFAT. (Author)

  11. Effects of reclaimed asphalt pavement on indirect tensile strength test of foamed asphalt mix tested in dry condition

    International Nuclear Information System (INIS)

    Katman, Herda Yati; Norhisham, Shuhairy; Ismail, Norlela; Ibrahim, Mohd Rasdan; Matori, Mohd Yazip

    2013-01-01

    Indirect tensile strength (ITS) test was conducted to analyse strength of the foamed asphalt mixes incorporating reclaimed asphalt pavement. Samples were tested for ITS after cured in the oven at 40°C for 72 hours. This testing condition known as dry condition or unconditioned. Laboratory results show that reclaimed asphalt pavement (RAP) contents insignificantly affect the ITS results. ITS results significantly affected by foamed bitumen contents.

  12. Association with isokinetic ankle strength measurements and normal clinical muscle testing in sciatica patients.

    Science.gov (United States)

    Ustun, N; Erol, O; Ozcakar, L; Ceceli, E; Ciner, O Akar; Yorgancioglu, Z R

    2013-01-01

    Sensitive muscle strength tests are needed to measure muscle strength in the diagnosis and management of sciatica patients. The aim of this study was to assess the isokinetic muscle strength in sciatica patients' and control subjects' ankles that exhibited normal ankle muscle strength when measured clinically. Forty-six patients with L5 and/or S1 nerve compression, and whose age, sex, weight, and height matched 36 healthy volunteers, were recruited to the study. Heel-walking, toe-walking, and manual muscle testing were used to perform ankle dorsiflexion and plantar flexion strengths in clinical examination. Patients with normal ankle dorsiflexion and plantar flexion strengths assessed by manual muscle testing and heel-and toe-walking tests were included in the study. Bilateral isokinetic (concentric/concentric) ankle plantar-flexion-dorsiflexion measurements of the patients and controls were performed within the protocol of 30°/sec (5 repetitions). Peak torque and peak torque/body weight were obtained for each ankle motion of the involved limb at 30°/s speed. L5 and/or S1 nerve compression was evident in 46 patients (76 injured limbs). Mean disease duration was two years. The plantar flexion muscle strength of the patients was found to be lower than that of the controls (p=0.036). The dorsiflexion muscle strength of the patients was found to be the same as that of the controls (p=0.211). Isokinetic testing is superior to clinical muscle testing when evaluating ankle plantar flexion torque in sciatica patients. Therefore, isokinetic muscle testing may be helpful when deciding whether to place a patient into a focused rehabilitation program.

  13. Predicting bending strength of fire-retardant-treated plywood from screw-withdrawal tests

    Science.gov (United States)

    J. E. Winandy; P. K. Lebow; W. Nelson

    This report describes the development of a test method and predictive model to estimate the residual bending strength of fire-retardant-treated plywood roof sheathing from measurement of screw-withdrawal force. The preferred test methodology is described in detail. Models were developed to predict loss in mean and lower prediction bounds for plywood bending strength as...

  14. Seismic proving test of ultimate piping strength (current status of preliminary tests)

    International Nuclear Information System (INIS)

    Suzuki, K.; Namita, Y.; Abe, H.; Ichihashi, I.; Suzuki, K.; Ishiwata, M.; Fujiwaka, T.; Yokota, H.

    2001-01-01

    In 1998 Fiscal Year, the 6 year program of piping tests was initiated with the following objectives: i) to clarify the elasto-plastic response and ultimate strength of nuclear piping, ii) to ascertain the seismic safety margin of the current seismic design code for piping, and iii) to assess new allowable stress rules. In order to resolve extensive technical issues before proceeding on to the seismic proving test of a large-scale piping system, a series of preliminary tests of materials, piping components and simplified piping systems is intended. In this paper, the current status of the material tests and the piping component tests is reported. (author)

  15. 46 CFR 111.81-1 - Outlet boxes and junction boxes; general.

    Science.gov (United States)

    2010-10-01

    ... fixture, wiring device, or similar item, including each separately installed connection and junction box... used. (d) As appropriate, each outlet-box or junction-box installation must meet the following...

  16. Analysis of Tests Evaluating Sport Climbers’ Strength and Isometric Endurance

    Directory of Open Access Journals (Sweden)

    Ozimek Mariusz

    2016-12-01

    Full Text Available The present study was designed to determine which types of specific tests provide an effective evaluation of strength and endurance in highly trained competitive sport climbers. The research process consisted of three basic components: the measurement of selected somatic characteristics of the climbers, the assessment of their physical conditioning, and a search for correlations between the anthropometric and “conditioning” variables on the one hand, and climber’s performance on the other. The sample of subjects consisted of 14 experienced volunteer climbers capable of handling 7a- 8a+/b on-sight rock climbing grades. The strongest correlations (Spearman’s rank were found between climber’s competence and the relative results of the finger strength test (r = 0.7; much lower, but still statistically significant coefficients were found between the level of competence and the results of the muscle endurance tests (r = 0.53 – 0.57. Climbers aspiring to attain an elite level must have strong finger and forearm muscles, but most of all, they must be capable of releasing their potential during specific motor capability tests engaging these parts of the body. The forearm muscles of elite climbers must also be very resistant to fatigue. Since highly trained athletes vary only slightly in body mass, this variable does not have a major effect on their performance during strength and endurance tests.

  17. Results from post-mortem tests with materials from the old core-box of the High Flux Reactor (HFR) at Petten

    International Nuclear Information System (INIS)

    de Vries, M.I.; Cundy, M.R.

    1990-01-01

    Results are reported from hardness measurements, tensile tests and fracture mechanics experiments (fatigue crack growth and fracture toughness) on 5154 aluminum specimens fabricated from remnants of the old HFR core box. The specimen material was exposed to a maximum thermal neutron fluence of 7.5 * 10 26 n/m 2 (E 26 n/m 2 , but with a thermal to fast neutron ratio of about 4, shows more radiation hardening : 67HR15N, 0.2 - yield strength 580 MPa and 1.5% total elongation. Fatigue crack growth rates range from 5 * 10 -5 mm/cycle to 10 -3 mm/cycle for ΔK ranging from 8 to 20 MPa√m. The most highly exposed (7.5 * 10 26 n/m 2 ) materials shows accelerated fatigue crack growth due to unstable crack extension at ΔK of about 15 MPa√m. The lowermost meaningful measure of plane strain fracture toughness is 18 MPa√m. Except for the fracture toughness, which is a factor of about 3 higher, the results show reasonable agreement with the expected mechanical properties estimated in the 'safe end-of-life' assessment of the old HFR vessel

  18. A Field Test for Upper Body Strength and Endurance.

    Science.gov (United States)

    Nelson, Jack K.; And Others

    1991-01-01

    Researchers studied the reliability of the modified push-up test in measuring upper body strength and endurance in elementary through college students. It also examined the accuracy of partner scoring. The test proved much easier to administer than the regular floor push-up. It was valid and reliable for all students and suitable for partner…

  19. Static and Dynamic Handgrip Strength Endurance: Test-Retest Reproducibility.

    Science.gov (United States)

    Gerodimos, Vassilis; Karatrantou, Konstantina; Psychou, Dimitra; Vasilopoulou, Theodora; Zafeiridis, Andreas

    2017-03-01

    This study investigated the reliability of static and dynamic handgrip strength endurance using different protocols and indicators for the assessment of strength endurance. Forty young, healthy men and women (age, 18-22 years) performed 2 handgrip strength endurance protocols: a static protocol (sustained submaximal contraction at 50% of maximal voluntary contraction) and a dynamic one (8, 10, and 12 maximal repetitions). The participants executed each protocol twice to assess the test-retest reproducibility. Total work and total time were used as indicators of strength endurance in the static protocol; the strength recorded at each maximal repetition, the percentage change, and fatigue index were used as indicators of strength endurance in the dynamic protocol. The static protocol showed high reliability irrespective of sex and hand for total time and work. The 12-repetition dynamic protocol exhibited moderate-high reliability for repeated maximal repetitions and percentage change; the 8- and 10-repetition protocols demonstrated lower reliability irrespective of sex and hand. The fatigue index was not a reliable indicator for the assessment of dynamic handgrip endurance. Static handgrip endurance can be measured reliably using the total time and total work as indicators of strength endurance. For the evaluation of dynamic handgrip endurance, the 12-repetition protocol is recommended, using the repeated maximal repetitions and percentage change as indicators of strength endurance. Practitioners should consider the static (50% maximal voluntary contraction) and dynamic (12 repeated maximal repetitions) protocols as reliable for the assessment of handgrip strength endurance. The evaluation of static endurance in conjunction with dynamic endurance would provide more complete information about hand function. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. Strength cues and blocking at test promote reliable within-list criterion shifts in recognition memory.

    Science.gov (United States)

    Hicks, Jason L; Starns, Jeffrey J

    2014-07-01

    In seven experiments, we explored the potential for strength-based, within-list criterion shifts in recognition memory. People studied a mix of target words, some presented four times (strong) and others studied once (weak). In Experiments 1, 2, 4A, and 4B, the test was organized into alternating blocks of 10, 20, or 40 trials. Each block contained lures intermixed with strong targets only or weak targets only. In strength-cued conditions, test probes appeared in a unique font color for strong and weak blocks. In the uncued conditions of Experiments 1 and 2, similar strength blocks were tested, but strength was not cued with font color. False alarms to lures were lower in blocks containing strong target words, as compared with lures in blocks containing weak targets, but only when strength was cued with font color. Providing test feedback in Experiment 2 did not alter these results. In Experiments 3A-3C, test items were presented in a random order (i.e., not blocked by strength). Of these three experiments, only one demonstrated a significant shift even though strength cues were provided. Overall, the criterion shift was larger and more reliable as block size increased, and the shift occurred only when strength was cued with font color. These results clarify the factors that affect participants' willingness to change their response criterion within a test list.

  1. A Comparison of Energy Expenditure During "Wii Boxing" Versus Heavy Bag Boxing in Young Adults.

    Science.gov (United States)

    Perusek, Kristen; Sparks, Kenneth; Little, Kathleen; Motley, Mary; Patterson, Sheila; Wieand, Jennifer

    2014-02-01

    Traditional computer videogames are sedentary, whereas new computer videogames, such as the Nintendo(®) (Redmond, WA) "Wii™ Sports" games, allow users to physically interact while playing the sport. Energy expenditure (EE), heart rate (HR), and rating of perceived exertion (RPE) during heavy bag boxing versus the Nintendo "Wii Boxing" game were compared. Fifteen males and 14 females (mean age, 25.6 years; height, 171.3 cm; weight, 71.8 kg) randomly selected (by a coin toss) heavy bag boxing or "Wii Boxing" for their first test session and completed the other protocol at their second session at least 2 days later. Each session lasted for a total duration of 30 minutes and consisted of 10 3-minute exercise bouts with measurements of HR, RPE, and EE obtained from indirect calorimetry. A paired-samples t test was used to analyze the results. Significant differences were found for HR (bag, 156 beats per minute; Wii, 138 beats per minute; P=0.001) and RPE (bag, 13.8; Wii, 11.4; P=0.0001) but not for EE (bag, 8.0 kcal/minute; Wii, 7.1 kcal/minute; bag, 241 total kcal; Wii, 213 total kcal; P=0.078). The results suggest that computer active videogames, such as the Nintendo Wii, have the potential to provide similar EE as their traditional forms of exercise and may be a sufficient replacement for traditional target HR zone activities, especially in less fit individuals. Further research is needed to compare EE for different "Wii Sports" games with those for their traditional forms of exercise.

  2. Tensile strength of concrete under static and intermediate strain rates: Correlated results from different testing methods

    International Nuclear Information System (INIS)

    Wu Shengxing; Chen Xudong; Zhou Jikai

    2012-01-01

    Highlights: ► Tensile strength of concrete increases with increase in strain rate. ► Strain rate sensitivity of tensile strength of concrete depends on test method. ► High stressed volume method can correlate results from various test methods. - Abstract: This paper presents a comparative experiment and analysis of three different methods (direct tension, splitting tension and four-point loading flexural tests) for determination of the tensile strength of concrete under low and intermediate strain rates. In addition, the objective of this investigation is to analyze the suitability of the high stressed volume approach and Weibull effective volume method to the correlation of the results of different tensile tests of concrete. The test results show that the strain rate sensitivity of tensile strength depends on the type of test, splitting tensile strength of concrete is more sensitive to an increase in the strain rate than flexural and direct tensile strength. The high stressed volume method could be used to obtain a tensile strength value of concrete, free from the influence of the characteristics of tests and specimens. However, the Weibull effective volume method is an inadequate method for describing failure of concrete specimens determined by different testing methods.

  3. Design and Evaluation of a Wireless Sensor Network Based Aircraft Strength Testing System

    Science.gov (United States)

    Wu, Jian; Yuan, Shenfang; Zhou, Genyuan; Ji, Sai; Wang, Zilong; Wang, Yang

    2009-01-01

    The verification of aerospace structures, including full-scale fatigue and static test programs, is essential for structure strength design and evaluation. However, the current overall ground strength testing systems employ a large number of wires for communication among sensors and data acquisition facilities. The centralized data processing makes test programs lack efficiency and intelligence. Wireless sensor network (WSN) technology might be expected to address the limitations of cable-based aeronautical ground testing systems. This paper presents a wireless sensor network based aircraft strength testing (AST) system design and its evaluation on a real aircraft specimen. In this paper, a miniature, high-precision, and shock-proof wireless sensor node is designed for multi-channel strain gauge signal conditioning and monitoring. A cluster-star network topology protocol and application layer interface are designed in detail. To verify the functionality of the designed wireless sensor network for strength testing capability, a multi-point WSN based AST system is developed for static testing of a real aircraft undercarriage. Based on the designed wireless sensor nodes, the wireless sensor network is deployed to gather, process, and transmit strain gauge signals and monitor results under different static test loads. This paper shows the efficiency of the wireless sensor network based AST system, compared to a conventional AST system. PMID:22408521

  4. Design and evaluation of a wireless sensor network based aircraft strength testing system.

    Science.gov (United States)

    Wu, Jian; Yuan, Shenfang; Zhou, Genyuan; Ji, Sai; Wang, Zilong; Wang, Yang

    2009-01-01

    The verification of aerospace structures, including full-scale fatigue and static test programs, is essential for structure strength design and evaluation. However, the current overall ground strength testing systems employ a large number of wires for communication among sensors and data acquisition facilities. The centralized data processing makes test programs lack efficiency and intelligence. Wireless sensor network (WSN) technology might be expected to address the limitations of cable-based aeronautical ground testing systems. This paper presents a wireless sensor network based aircraft strength testing (AST) system design and its evaluation on a real aircraft specimen. In this paper, a miniature, high-precision, and shock-proof wireless sensor node is designed for multi-channel strain gauge signal conditioning and monitoring. A cluster-star network topology protocol and application layer interface are designed in detail. To verify the functionality of the designed wireless sensor network for strength testing capability, a multi-point WSN based AST system is developed for static testing of a real aircraft undercarriage. Based on the designed wireless sensor nodes, the wireless sensor network is deployed to gather, process, and transmit strain gauge signals and monitor results under different static test loads. This paper shows the efficiency of the wireless sensor network based AST system, compared to a conventional AST system.

  5. Evaluation of microtensile and tensile bond strength tests ...

    African Journals Online (AJOL)

    Objectives: The aim of the present study was to compare two different bond strength test methods (tensile and microtensile) in investing the influence of erbium, chromium: yttrium‑scandium‑gallium‑garnet (Er, Cr: YSGG) laser pulse frequency on resin‑enamel bonding. Materials and Methods: One‑hundred and twenty‑five ...

  6. Standard test method for splitting tensile strength for brittle nuclear waste forms

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1989-01-01

    1.1 This test method is used to measure the static splitting tensile strength of cylindrical specimens of brittle nuclear waste forms. It provides splitting tensile-strength data that can be used to compare the strength of waste forms when tests are done on one size of specimen. 1.2 The test method is applicable to glass, ceramic, and concrete waste forms that are sufficiently homogeneous (Note 1) but not to coated-particle, metal-matrix, bituminous, or plastic waste forms, or concretes with large-scale heterogeneities. Cementitious waste forms with heterogeneities >1 to 2 mm and 5 mm can be tested using this procedure provided the specimen size is increased from the reference size of 12.7 mm diameter by 6 mm length, to 51 mm diameter by 100 mm length, as recommended in Test Method C 496 and Practice C 192. Note 1—Generally, the specimen structural or microstructural heterogeneities must be less than about one-tenth the diameter of the specimen. 1.3 This test method can be used as a quality control chec...

  7. Prediction on flexural strength of encased composite beam with cold-formed steel section

    Science.gov (United States)

    Khadavi, Tahir, M. M.

    2017-11-01

    A flexural strength of composite beam designed as boxed shaped section comprised of lipped C-channel of cold-formed steel (CFS) facing each other with reinforcement bars is proposed in this paper. The boxed shaped is kept restrained in position by a profiled metal decking installed on top of the beam to form a slab system. This profiled decking slab is cast by using self-compacting concrete where the concrete is in compression when load is applied to the beam. Reinforcement bars are used as shear connector between slab and CFS as beam. A numerical analysis method proposed by EC4 is used to predict the flexural strength of the proposed composite beam. It was assumed that elasto-plastic behaviour is developed in the cross -sectional of the proposed beam. The calculated predicted flexural strength of the proposed beam shows reasonable flexural strength for cold-formed composite beam.

  8. Insulation interlaminar shear strength testing with compression and irradiation

    International Nuclear Information System (INIS)

    McManamy, T.J.; Brasier, J.E.; Snook, P.

    1989-01-01

    The Compact Ignition Tokamak (CIT) project identified the need for research and development for the insulation to be used in the toroidal field coils. The requirements included tolerance to a combination of high compression and shear and a high radiation dose. Samples of laminate-type sheet material were obtained from commercial vendors. The materials included various combinations of epoxy, polyimide, E-glass, S-glass, and T-glass. The T-glass was in the form of a three-dimensional weave. The first tests were with 50 x 25 x 1 mm samples. These materials were loaded in compression and then to failure in shear. At 345-MPa compression, the interlaminar shear strength was generally in the range of 110 to 140 MPa for the different materials. A smaller sample configuration was developed for irradiation testing. The data before irradiation were similar to those for the larger samples but approximately 10% lower. Limited fatigue testing was also performed by cycling the shear load. No reduction in shear strength was found after 50,000 cycles at 90% of the failure stress. Because of space limitations, only three materials were chosen for irradiation: two polyimide systems and one epoxy system. All used boron-free glass. The small shear/compression samples and some flexure specimens were irradiated to 4 x 10 9 and 2 x 10 10 rad in the Advanced Technology Reactor at Idaho National Engineering Laboratory. A lead shield was used to ensure that the majority of the dose was from neutrons. The shear strength with compression before and after irradiation at the lower dose was determined. Flexure strength and the results from irradiation at the higher dose level will be available in the near future. 7 refs., 7 figs., 2 tabs

  9. Fatigue testing of weldable high strength steels under simulated service conditions

    Science.gov (United States)

    Tantbirojn, Natee

    There have been concerns over the effect of Cathodic Protection (CP) on weldable high strength steels employed in Jack-up production platform. The guidance provided by the Department of Energy HSE on higher strength steels, based on previous work, was to avoid overprotection as this could cause hydrogen embrittlement. However, the tests conducted so far at UCL for the SE702 type high strength steels (yields strength around 690 MPa) have shown that the effect of over protection on high strength steels may not be as severe as previously thought. For this thesis, SE702 high strength steels have been investigated in more detail. Thick (85mm) parent and ground welded plates were tested under constant amplitude in air and seawater with CP. Tests were also conducted on Thick (40mm) T-butt welded plates under variable amplitude loading in air and seawater with two CP levels (-800mV and -1050mV). Different backing materials (ceramic and metallic) for the welding process of the T-butt plates were also investigated. The variable amplitude sequences employed were generated using the Jack-up Offshore Standard load History (JOSH). The fatigue results are presented as crack growth and S/N curves. They were compared to the conventional offshore steel (BS 4360 50D). The results suggested that the fatigue life of the high strength steels was comparable to the BS 4360 50D steels. The effect of increasing the CP was found to be detrimental to the fatigue life but the effect was not large. The effect of CP was less noticeable in T-butt welded plates. However, in general, the effect of overprotection is not as detrimental to the Jack-up steels as previously thought. The load histories generated by JOSH were found to have some unfavourable characteristics. The framework is based on Markov Chain method and pseudo-random number generator for selecting sea-states. A study was carried out on the sequence generated by JOSH. The generated sequences were analysed for their validity for fatigue

  10. A Lithium Vapor Box Divertor Similarity Experiment

    Science.gov (United States)

    Cohen, Robert A.; Emdee, Eric D.; Goldston, Robert J.; Jaworski, Michael A.; Schwartz, Jacob A.

    2017-10-01

    A lithium vapor box divertor offers an alternate means of managing the extreme power density of divertor plasmas by leveraging gaseous lithium to volumetrically extract power. The vapor box divertor is a baffled slot with liquid lithium coated walls held at temperatures which increase toward the divertor floor. The resulting vapor pressure differential drives gaseous lithium from hotter chambers into cooler ones, where the lithium condenses and returns. A similarity experiment was devised to investigate the advantages offered by a vapor box divertor design. We discuss the design, construction, and early findings of the vapor box divertor experiment including vapor can construction, power transfer calculations, joint integrity tests, and thermocouple data logging. Heat redistribution of an incident plasma-based heat flux from a typical linear plasma device is also presented. This work supported by DOE Contract No. DE-AC02-09CH11466 and The Princeton Environmental Institute.

  11. Channel box

    International Nuclear Information System (INIS)

    Tanabe, Akira.

    1993-01-01

    In a channel box of a BWR type reactor, protruding pads are disposed in axial position on the lateral side of a channel box opposing to a control rod and facing the outer side portion of the control rod in a reactor core loaded state. In the initial loading stage of fuel assemblies, channel fasteners and spacer pads are abutted against each other in the upper portion between the channel boxes sandwiching the control rod therebetween. Further, in the lower portion, a gap as a channel for the movement of the control rod is ensured by the support of fuel support metals. If the channel box is bent toward the control rod along with reactor operation, the pads are abutted against each other to always ensure the gap through which the control rod can move easily. Further, when the pads are brought into contact with each other, the bending deformation of the channel box is corrected by urging to each other. Thus, the control rod can always be moved smoothly to attain reactor safety operation. (N.H.)

  12. Tensile strength and the mining of black holes.

    Science.gov (United States)

    Brown, Adam R

    2013-11-22

    There are a number of important thought experiments that involve raising and lowering boxes full of radiation in the vicinity of black hole horizons. This Letter looks at the limitations placed on these thought experiments by the null energy condition, which imposes a fundamental bound on the tensile-strength-to-weight ratio of the materials involved, makes it impossible to build a box near the horizon that is wider than a single wavelength of the Hawking quanta, and puts a severe constraint on the operation of "space elevators" near black holes. In particular, it is shown that proposals for mining black holes by lowering boxes near the horizon, collecting some Hawking radiation, and dragging it out to infinity cannot proceed nearly as rapidly as has previously been claimed. As a consequence of this limitation, the boxes and all the moving parts are superfluous and black holes can be destroyed equally rapidly by threading the horizon with strings.

  13. Single-Leg Hop Test Performance and Isokinetic Knee Strength After Anterior Cruciate Ligament Reconstruction in Athletes.

    Science.gov (United States)

    Sueyoshi, Ted; Nakahata, Akihiro; Emoto, Gen; Yuasa, Tomoki

    2017-11-01

    Isokinetic strength and hop tests are commonly used to assess athletes' readiness to return to sport after knee surgery. The purpose of this study was to investigate the results of single-leg hop and isokinetic knee strength testing in athletes who underwent anterior cruciate ligament reconstruction (ACLR) upon returning to sport participation as well as to study the correlation between these 2 test batteries. The secondary purpose was to compare the test results by graft type (patellar tendon or hamstring). It was hypothesized that there would be no statistically significant limb difference in either isokinetic knee strength or single-leg hop tests, that there would be a moderate to strong correlation between the 2 test batteries, and that there would be no significant difference between graft types. Cross-sectional study; Level of evidence, 3. Twenty-nine high school and collegiate athletes who underwent ACLR participated in this study. At the time of return to full sport participation, a series of hop tests and knee extension/flexion isokinetic strength measurements were conducted. The results were analyzed using analysis of variance and Pearson correlation ( r ). The timed 6-m hop test was the only hop test that showed a significant difference between the involved and uninvolved limbs (2.3 and 2.2 seconds, respectively; P = .02). A significant difference between limbs in knee strength was found for flexion peak torque/body weight at 180 deg/s ( P = .03), flexion total work/body weight at 180 deg/s ( P = .04), and flexion peak torque/body weight at 300 deg/s ( P = .03). The strongest correlation between the hop tests and knee strength was found between the total distance of the hop tests and flexion total work/body weight at 300 deg/s ( r = 0.69) and between the timed 6-m hop test and flexion peak torque/body weight at 300 deg/s ( r = -0.54). There was no statistically significant difference in hop test performance or isokinetic knee strength between graft types

  14. Comparison of two bond strength testing methodologies for bilayered all-ceramics.

    Science.gov (United States)

    Dündar, Mine; Ozcan, Mutlu; Gökçe, Bülent; Cömlekoğlu, Erhan; Leite, Fabiola; Valandro, Luiz Felipe

    2007-05-01

    This study compared the shear bond strength (SBS) and microtensile (MTBS) testing methodologies for core and veneering ceramics in four types of all-ceramic systems. Four different ceramic veneer/core combinations, three of which were feldspathic and the other a fluor-apatite to their respectively corresponding cores, namely leucite-reinforced ceramic ((IPS)Empress, Ivoclar), low leucite-reinforced ceramic (Finesse, Ceramco), glass-infiltrated alumina (In-Ceram Alumina, Vita) and lithium disilicate ((IPS)Empress 2, Ivoclar) were used for SBS and MTBS tests. Ceramic cores (N=40, n=10/group for SBS test method, N=5 blocks/group for MTBS test method) were fabricated according to the manufacturers' instructions (for SBS: thickness, 3mm; diameter, 5mm and for MTBS: 10 mm x 10 mm x 2 mm) and ultrasonically cleaned. The veneering ceramics (thickness: 2mm) were vibrated and condensed in stainless steel moulds and fired onto the core ceramic materials. After trying the specimens in the mould for minor adjustments, they were again ultrasonically cleaned and embedded in PMMA. The specimens were stored in distilled water at 37 degrees C for 1 week and bond strength tests were performed in universal testing machines (cross-head speed: 1mm/min). The bond strengths (MPa+/-S.D.) and modes of failures were recorded. Significant difference between the two test methods and all-ceramic types were observed (P<0.05) (2-way ANOVA, Tukey's test and Bonferroni). The mean SBS values for veneering ceramic to lithium disilicate was significantly higher (41+/-8 MPa) than those to low leucite (28+/-4 MPa), glass-infiltrated (26+/-4 MPa) and leucite-reinforced (23+/-3 MPa) ceramics, while the mean MTBS for low leucite ceramic was significantly higher (15+/-2 MPa) than those of leucite (12+/-2 MPa), glass-infiltrated (9+/-1 MPa) and lithium disilicate ceramic (9+/-1 MPa) (ANOVA, P<0.05). Both the testing methodology and the differences in chemical compositions of the core and veneering ceramics

  15. Study on structural integrity in box structures

    International Nuclear Information System (INIS)

    Asano, Masayuki; Ueta, Masahiro; Kanaoka, Tadashi; Ikeuchi, Toshiaki; Kodama, Tetsuhiro.

    1991-01-01

    This study was carried out to give an experimental foundation to the structural integrity of a box structure. Crack growth tests were performed on the reduced scale models, simulating typical portions of the box structure, in air at room temperature. The results show that the amount of crack growth is too small to injure the structural integrity of the models for the postulated loading cycle, and make clear the effective structure against crack growth. (author)

  16. Preliminary analysis on hybrid Box-Jenkins - GARCH modeling in forecasting gold price

    Science.gov (United States)

    Yaziz, Siti Roslindar; Azizan, Noor Azlinna; Ahmad, Maizah Hura; Zakaria, Roslinazairimah; Agrawal, Manju; Boland, John

    2015-02-01

    Gold has been regarded as a valuable precious metal and the most popular commodity as a healthy return investment. Hence, the analysis and prediction of gold price become very significant to investors. This study is a preliminary analysis on gold price and its volatility that focuses on the performance of hybrid Box-Jenkins models together with GARCH in analyzing and forecasting gold price. The Box-Cox formula is used as the data transformation method due to its potential best practice in normalizing data, stabilizing variance and reduces heteroscedasticity using 41-year daily gold price data series starting 2nd January 1973. Our study indicates that the proposed hybrid model ARIMA-GARCH with t-innovation can be a new potential approach in forecasting gold price. This finding proves the strength of GARCH in handling volatility in the gold price as well as overcomes the non-linear limitation in the Box-Jenkins modeling.

  17. Equipment and Protocols for Quasi-Static and Dynamic Tests of Very-High-Strength Concrete (VHSC) and High-Strength High-Ductility Concrete (HSHDC)

    Science.gov (United States)

    2016-08-01

    Concrete (VHSC) and High-Strength High-Ductility Concrete (HSHDC) En gi ne er R es ea rc h an d D ev el op m en t Ce nt er Brett A...Very-High-Strength Concrete (VHSC) and High-Strength High-Ductility Concrete (HSHDC) Brett A. Williams, Robert D. Moser, William F. Heard, Carol F...equipment and protocols for tests of both very-high-strength concrete (VHSC) and high- strength high-ductility concrete (HSHDC) to predict blast

  18. Feasibility and test-retest reliability of measuring lower‑limb strength in young children with cerebral palsy.

    Science.gov (United States)

    Van Vulpen, L F; De Groot, S; Becher, J G; De Wolf, G S; Dallmeijer, A J

    2013-12-01

    Quantifying leg muscle strength in young children with cerebral palsy (CP) is essential for identifying muscle groups for treatment and for monitoring progress. To study the feasibility, intratester reliability and the optimal test design (number of test occasions and repetitions) of measuring lower-limb strength with handheld dynamometry (HHD) and dynamic ankle plantar flexor strength with the standing heel-rise (SH) test in 3-10 year aged children with CP. Test-retest design. Rehabilitation centre, special needs school for children with disabilities, and university medical centre. Knee extensor, hip abductor and calf muscle strength was assessed in 20 ambulatory children with spastic CP (3-5 years [N.=10] and 6-10 years [N.=10]) on two test occasions. Intraclass correlation coefficients (ICC) and Smallest Detectable Differences (SDD) were calculated to determine the optimal test design for detecting changes in strength. All isometric strength tests had acceptable SDDs (9-30%), when taking the mean values of 2-3 test occasions (separate days) and 2-3 repetitions. The one-leg SH test had large SDDs (40-128% for younger group, 23-48% for older group). Isometric strength (improvements) can only be measured reliably with HHD in young children with CP when the average values over at least 2 test occasions are taken. Reliability of the SH test is not sufficient for measuring individual changes in dynamic muscle strength in the younger children. Results of this study can be used to determine the optimal number of test occasions and repetitions for reliable HHD measurements depending on expected changes, muscle group and age in 3-10 year old children with CP.

  19. Push-off tests and strength evaluation of joints combining shrink fitting with bonding

    Science.gov (United States)

    Yoneno, Masahiro; Sawa, Toshiyuki; Shimotakahara, Ken; Motegi, Yoichi

    1997-03-01

    Shrink fitted joints have been used in mechanical structures. Recently, joints combining shrink fitting with anaerobic adhesives bonded between the shrink fitted surfaces have been appeared in order to increase the joint strength. In this paper, push-off test was carried out on strength of joints combining shrink fitting with bonding by material testing machine. In addition, the push-off strength of shrink fitting joints without an anaerobic adhesive was also measured. In the experiments, the effects of the shrinking allowance and the outer diameter of the rings on the joint strength are examined. The interface stress distribution in bonded shrink fitted joints subjected to a push-off load is analyzed using axisymmetrical theory of elasticity as a four-body contact problem. Using the interface stress distribution, a method for estimating joint strength is proposed. The experimental results are in a fairly good agreement with the numerical results. It is found that the strength of combination joints is greater than that of shrink fitted joints.

  20. Correlation of single-breath count test and neck flexor muscle strength with spirometry in myasthenia gravis.

    Science.gov (United States)

    Elsheikh, Bakri; Arnold, W David; Gharibshahi, Shahram; Reynolds, Jerold; Freimer, Miriam; Kissel, John T

    2016-01-01

    Although formal spirometry is the gold standard for monitoring respiratory function in patients with myasthenia gravis (MG), such testing is often delayed or unavailable. There is a need for a simple bedside test that can accurately measure respiratory function. We conducted a prospective, cross-sectional, single-blind study in adults with acetylcholine receptor antibody positive MG. Participants performed the single breath count test (SBCT) and underwent manual muscle strength testing, and a respiratory therapist performed spirometry blinded to SBCT and strength results. Thirty-one patients, aged 57 ± 19 years participated. SBCT showed significant correlations with forced vital capacity (FVC), negative inspiratory force, and neck flexor strength (P strength (P = 0.02) but no correlation with shoulder abductor strength. These data suggest that the SBCT and neck flexor strength testing are valuable tools for bedside assessment of respiratory function in MG patients. © 2015 Wiley Periodicals, Inc.

  1. Beam Test for Evaluating Applicabillity of High - Strength Reinforcement in Structure of Nuclear Facility

    International Nuclear Information System (INIS)

    Yim, Sangjun; Lee, Byungsoo; Bang, Changjoon

    2014-01-01

    The high-strength rebar which has high yield strength can reduce the amount of rebar in concrete and widen its spacing so that it has better workability and higher economic benefits for the structure. However, the maximum yield strength of rebar is limited to 420MPa in the design criteria for structure of nuclear facility in Korea and USA. Korea Hydro and Nuclear Power is progressing research to revise the limitation in the yield strength of rebar, which is suggested in the criteria of KEPIC and ACI, in order to apply 550 MPa high-strength rebar for the construction of a nuclear facility. This study is to review the applicability of high strength rebar in structure of a nuclear facility through a model beam test. After reviewing the shear capacity and reinforcement yield to assess the applicability of high-strength reinforcement in the structure of a nuclear facility, we make the following conclusions. When using high shear reinforcement with wider spacing, it has a similar shear capacity to normal reinforcement with narrower spacing. This means better workability and economic benefits can be achieved by widening the rebar spacing without brittle fracture in the elements. For future plans, the results of this test and supplementary test will be submitted to ACI349 committee as backup data to revise the standard for yield strength of high-strength rebar

  2. Beam Test for Evaluating Applicabillity of High - Strength Reinforcement in Structure of Nuclear Facility

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Sangjun; Lee, Byungsoo; Bang, Changjoon [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2014-05-15

    The high-strength rebar which has high yield strength can reduce the amount of rebar in concrete and widen its spacing so that it has better workability and higher economic benefits for the structure. However, the maximum yield strength of rebar is limited to 420MPa in the design criteria for structure of nuclear facility in Korea and USA. Korea Hydro and Nuclear Power is progressing research to revise the limitation in the yield strength of rebar, which is suggested in the criteria of KEPIC and ACI, in order to apply 550 MPa high-strength rebar for the construction of a nuclear facility. This study is to review the applicability of high strength rebar in structure of a nuclear facility through a model beam test. After reviewing the shear capacity and reinforcement yield to assess the applicability of high-strength reinforcement in the structure of a nuclear facility, we make the following conclusions. When using high shear reinforcement with wider spacing, it has a similar shear capacity to normal reinforcement with narrower spacing. This means better workability and economic benefits can be achieved by widening the rebar spacing without brittle fracture in the elements. For future plans, the results of this test and supplementary test will be submitted to ACI349 committee as backup data to revise the standard for yield strength of high-strength rebar.

  3. The 1-Minute Sit-to-Stand Test in Adults With Cystic Fibrosis: Correlations With Cardiopulmonary Exercise Test, 6-Minute Walk Test, and Quadriceps Strength.

    Science.gov (United States)

    Gruet, Mathieu; Peyré-Tartaruga, Leonardo Alexandre; Mely, Laurent; Vallier, Jean-Marc

    2016-12-01

    Exercise testing is part of the regular assessment of patients with cystic fibrosis (CF). We aimed to evaluate (1) the convergent validity of the 1-min sit-to-stand (STS) test in CF by investigating its relationships with peak oxygen uptake (peak V̇ O 2 ), quadriceps strength, and quality of life and (2) to compare these associations with those of the 6-min walk test (6MWT). Twenty-five adults with CF (FEV 1 = 59 ± 24%) performed the STS test, the 6MWT, quadriceps strength assessment, and cardiopulmonary exercise test (CPET). Physical activity level, quality of life, and self-esteem were assessed by questionnaires. STS repetitions, 6-min walk distance, quadriceps strength, and peak V̇ O 2 were, respectively, 71 ± 12, 90 ± 10, 93 ± 29, and 62 ± 16% of predicted. The STS test had moderate associations with peak V̇ O 2 (r = 0.56, P = .004), quadriceps strength (r = 0.52, P = .008), and some questionnaire items (eg, perceived physical strength, r = 0.67, P test was strongly associated with oxygen desaturation during CPET (r = 0.80, P test as compared with CPET (P test cannot be used as a replacement for CPET to accurately assess peak exercise capacity in CF. The STS test may have utility in detecting patients with CF who may exhibit a high level of oxygen desaturation during heavy exercise. Further studies should identify the factors contributing to STS performance to confirm the potential interest of STS repetitions × body weight outcome as a useful submaximal exercise parameter in CF. Copyright © 2016 by Daedalus Enterprises.

  4. Hip strength and star excursion balance test deficits of patients with chronic ankle instability.

    Science.gov (United States)

    McCann, Ryan S; Crossett, Ian D; Terada, Masafumi; Kosik, Kyle B; Bolding, Brenn A; Gribble, Phillip A

    2017-11-01

    To examine isometric hip strength in those with and without CAI, and determine the degree of Star Excursion Balance Test (SEBT) variance explained by isometric hip strength. Single-blinded, cross-sectional, case-control study. Thirty individuals with CAI, 29 lateral ankle sprain (LAS) copers, and 26 healthy controls participated. We assessed dynamic postural control with the SEBT anterior (SEBT-ANT), posteromedial (SEBT-PM), and posterolateral (SEBT-PL) reaches, and isometric hip extension (EXT), abduction (ABD) and external rotation (ER) strength with hand-held dynamometry. The CAI and LAS coper groups' involved limbs and randomly selected limbs in controls were tested. Separate Kruskal-Wallis tests compared SEBT scores and isometric hip strength between groups. Backwards linear regression models determined the degree of SEBT variance explained by isometric hip strength. Statistical significance was set a priori at Phip strength compared to LAS copers and controls. Additionally, the CAI group's isometric hip strength significantly influenced dynamic postural control performance. Future CAI rehabilitation strategies should consider hip muscular strengthening to facilitate improvements in dynamic postural control. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  5. [Effects of education and strength training on functional tests among older people with osteoarthritis].

    Science.gov (United States)

    Jiménez S, Christian Edgardo; Fernández G, Rubén; Zurita O, Félix; Linares G, Daniel; Farías M, Ariel

    2014-04-01

    Hip and knee osteoarthritis are important causes of pain and disability among older people. Education and strength training can alleviate symptoms and avoid functional deterioration. To assess muscle strength, fall risk and quality of life of older people with osteoarthritis and the effects of physiotherapy education and strength training on these variables. Thirty participants aged 78 ± 5 years (63% women) were randomly assigned to receive physiotherapy (Controls), physiotherapy plus education (Group 1) and physiotherapy plus strength training (group 2). At baseline and after 16 weeks of intervention, patients were evaluated with the Senior Fitness Test, Timed Up and Go and Quality of Life score short form (SF-36). During the intervention period, Senior Fitness Test and Timed Up and Go scores improved in all groups and SF-36 did not change. The improvement in Senior Fitness Test and Timed Up and Go was more marked in Groups 1 and 2 than in the control group. Education and strength training improve functional tests among older people with osteoarthritis.

  6. Temperature-dependent residual shear strength characteristics of smectite-rich landslide soils

    Science.gov (United States)

    Shibasaki, Tatsuya; Matsuura, Sumio; Okamoto, Takashi

    2015-04-01

    On gentle clayey slopes in weathered argillaceous rock areas, there exist many landslides which repeatedly reactivate with slow movement. The slip surface soils of these landslides are sometimes composed dominantly of swelling clay mineral (smectite) which is well known to show extremely low residual friction angle. From field data monitored at landslide sites in Japan, it has become clear that some landslides with relatively shallow slip surface begin to move and become active in late autumn or early winter every year. In such cases, the triggering mechanisms of landslides have not been understood well enough, because landslide initiation and movement are not always clearly linked with rises in pore water pressures (ground water levels). In this study, we focus on the influence of seasonal variation in ground temperature on slope stability and have investigated the effect of temperature on the shear strength of slip surface soils. Undisturbed soil samples were collected by boring from the Busuno landslide in Japan. We performed box shear experiments on undisturbed slip surface soils at low temperature ranges (approximately 5-25 °C). XRD analysis revealed that these soils contain high fraction of smectite. Slickensided slip surface within test specimen was coincided with the shearing plane of the shear box and shear displacement was applied precisely along the localized slip surface. Experiments were performed under slow shearing rate condition (0.005mm/min) and the results showed that shear strength decreased with decreasing temperature. Temperature effect was rather significant on frictional angle than on cohesion. Ring shear experiments were also performed on normally-consolidated remoulded samples. Under residual strength condition, temperature-change experiments (cooling-event tests) ranging approximately from 5 to 25 °C were performed on smectite-rich landslide soils and commercial bentonites. As well as the results by box shear test, shear weakening

  7. Optimal Scoring Methods of Hand-Strength Tests in Patients with Stroke

    Science.gov (United States)

    Huang, Sheau-Ling; Hsieh, Ching-Lin; Lin, Jau-Hong; Chen, Hui-Mei

    2011-01-01

    The purpose of this study was to determine the optimal scoring methods for measuring strength of the more-affected hand in patients with stroke by examining the effect of reducing measurement errors. Three hand-strength tests of grip, palmar pinch, and lateral pinch were administered at two sessions in 56 patients with stroke. Five scoring methods…

  8. Orthodontic brackets removal under shear and tensile bond strength resistance tests - a comparative test between light sources

    Science.gov (United States)

    Silva, P. C. G.; Porto-Neto, S. T.; Lizarelli, R. F. Z.; Bagnato, V. S.

    2008-03-01

    We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 ± 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

  9. Air tight electrical box

    Energy Technology Data Exchange (ETDEWEB)

    Pringle, C.G.

    1990-08-14

    An air-impervious electrical box to facilitate air sealing a house comprises an integral, rigid box body having a continuous flange, integral with the body, circumscribing and outwardly extending from the sides of the body. This flange is rearwardly positioned behind the front edges of the sides of the body a predetermined distance so that the electrical box may be secured to framing by nailing through the flange. Drywall is then secured to the frame on top of and adjecent to the flange. Such box eliminates the necessity for solid backing and minimizes passage of air through the box and space between the drywall and the box.

  10. Experts’ Misinterpretation of Box Plots – a Dual Processing Approach

    Directory of Open Access Journals (Sweden)

    Stephanie Lem

    2014-11-01

    Full Text Available Recent studies have shown that students often misinterpret the area of the box in box plots as representing the frequency or proportion of observations in that interval, while it actually represents density. This misinterpretation has been shown to be based on the saliency of this area and can be explained by heuristic reasoning as defined by dual process theories. In this study we tested whether expert users of box plots also display this misinterpretation and show signs of the same heuristic reasoning as found in students. Using a reaction time test, we found signs of heuristic reasoning in experts, both with respect to accuracy and reaction times. If even experts have difficulty interpreting box plots, one can question whether these are an appropriate form of representation to use when reporting data and deserve the prominent place they currently have in the statistics curriculum.

  11. Handgrip strength test as a complementary tool in monitoring asthma in daily clinical practice in children.

    Science.gov (United States)

    Latorre-Román, Pedro Ángel; Navarro-Martínez, Ana Vanesa; Mañas-Bastidas, Alfonso; García-Pinillos, Felipe

    2014-12-01

    The aim of this study was to demonstrate that handgrip strength test can discriminate the presence/absence of asthma and between intermittent and moderate persistent asthma in children. 140 children (70 healthy and 70 with asthma) completed the Pediatric Asthma Quality of Life Questionnaire (PAQLQ) and performed the handgrip strength test. Forty-eight hours later, subjects performed spirometry. The results showed Handgrip strength was significantly lower (pstrength test was a predictive factor for asthma (cut-off at 16.84 kg) and for severity of pathology (cut-off at 15.06 kg). Handgrip strength was reduced in children with asthma. Handgrip strength was positively associated with lung capacity and quality of life. The fact that the handgrip strength test was able to discriminate between presence/absence of asthma and between intermittent and moderate persistent asthma in children suggested that this test could be used as a complementary tool in the monitoring of asthma in daily clinical practice.

  12. Reliability of Maximal Strength Testing in Novice Weightlifters

    Science.gov (United States)

    Loehr, James A.; Lee, Stuart M. C.; Feiveson, Alan H.; Ploutz-Snyder, Lori L.

    2009-01-01

    The one repetition maximum (1RM) is a criterion measure of muscle strength. However, the reliability of 1RM testing in novice subjects has received little attention. Understanding this information is crucial to accurately interpret changes in muscle strength. To evaluate the test-retest reliability of a squat (SQ), heel raise (HR), and deadlift (DL) 1RM in novice subjects. Twenty healthy males (31 plus or minus 5 y, 179.1 plus or minus 6.1 cm, 81.4 plus or minus 10.6 kg) with no weight training experience in the previous six months participated in four 1RM testing sessions, with each session separated by 5-7 days. SQ and HR 1RM were conducted using a smith machine; DL 1RM was assessed using free weights. Session 1 was considered a familiarization and was not included in the statistical analyses. Repeated measures analysis of variance with Tukey fs post-hoc tests were used to detect between-session differences in 1RM (p.0.05). Test-retest reliability was evaluated by intraclass correlation coefficients (ICC). During Session 2, the SQ and DL 1RM (SQ: 90.2 }4.3, DL: 75.9 }3.3 kg) were less than Session 3 (SQ: 95.3 }4.1, DL: 81.5 plus or minus 3.5 kg) and Session 4 (SQ: 96.6 }4.0, DL: 82.4 }3.9 kg), but there were no differences between Session 3 and Session 4. HR 1RM measured during Session 2 (150.1 }3.7 kg) and Session 3 (152.5 }3.9 kg) were not different from one another, but both were less than Session 4 (157.5 }3.8 kg). The reliability (ICC) of 1RM measures for Sessions 2-4 were 0.88, 0.83, and 0.87, for SQ, HR, and DL, respectively. When considering only Sessions 3 and 4, the reliability was 0.93, 0.91, and 0.86 for SQ, HR, and DL, respectively. One familiarization session and 2 test sessions (for SQ and DL) were required to obtain excellent reliability (ICC greater than or equal to 0.90) in 1RM values with novice subjects. We were unable to attain this level of reliability following 3 HR testing sessions therefore additional sessions may be required to obtain an

  13. Adhesion strength study of IBAD-MOCVD-based 2G HTS wire using a peel test

    International Nuclear Information System (INIS)

    Zhang, Y.; Hazelton, D.W.; Knoll, A.R.; Duval, J.M.; Brownsey, P.; Repnoy, S.; Soloveichik, S.; Sundaram, A.; McClure, R.B.; Majkic, G.; Selvamanickam, V.

    2012-01-01

    A peel test was used to study the adhesion strength of a commercial grade 2G HTS wire which features a characteristic multilayer structure with the rare earth-based MOCVD superconducting film deposited on an IBAD-MgO template. The peel test could be carried out at various peeling angles (from 90° to 180°) and the peel strength of a wire was defined as the steady-state peeling load determined from a load-displacement curve. The test results had good reproducibility and accuracy, making the test a reliable and useful method for studying the adhesion strength of the wire. By characterizing the peeled surfaces the weakest interface in a wire could be identified. The peel strength data of the wire was analyzed together with the performance of the experimental magnet coils fabricated using the wire. The effect of the silver contact layer annealing on the peel strength is discussed.

  14. Relative strength of tailor's bunion osteotomies and fixation techniques.

    Science.gov (United States)

    Haddon, Todd B; LaPointe, Stephan J

    2013-01-01

    A paucity of data is available on the mechanical strength of fifth metatarsal osteotomies. The present study was designed to provide that information. Five osteotomies were mechanically tested to failure using a materials testing machine and compared with an intact fifth metatarsal using a hollow saw bone model with a sample size of 10 for each construct. The osteotomies tested were the distal reverse chevron fixated with a Kirschner wire, the long plantar reverse chevron osteotomy fixated with 2 screws, a mid-diaphyseal sagittal plane osteotomy fixated with 2 screws, the mid-diaphyseal sagittal plane osteotomy fixated with 2 screws, and an additional cerclage wire and a transverse closing wedge osteotomy fixated with a box wire technique. Analysis of variance was performed, resulting in a statistically significant difference among the data at p chevron was statistically the strongest construct at 130 N, followed by the long plantar osteotomy at 78 N. The chevron compared well with the control at 114 N, and they both fractured at the proximal model to fixture interface. The other osteotomies were statistically and significantly weaker than both the chevron and the long plantar constructs, with no statistically significant difference among them at 36, 39, and 48 N. In conclusion, the chevron osteotomy was superior in strength to the sagittal and transverse plane osteotomies and similar in strength and failure to the intact model. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Plutonium glove boxes - metrology and operational states

    International Nuclear Information System (INIS)

    Thyer, A.M.

    2001-01-01

    The main objective was to undertake a literature review in support of NII's ongoing work in improving safety in the nuclear industry to help define suitable standards of cleanliness for plutonium glove boxes. This is to cover the following areas: existing or proposed national/international standards relating to plutonium glove box cleanliness management; practicable metrology options for assessing the plutonium content of glove boxes; any available dose information relating to the operation of modern and 'old design'; current contamination levels of specific significance (i.e. any accepted level in decommissioning/waste terms, typical criticality limits (if available), any box plutonium loadings that are documented with corresponding operator doses etc.); and, techniques for the decontamination of plutonium glove boxes and their relative effectiveness. This should then form the basis of any further development work undertaken by the UK nuclear industry. Main recommendations are as follows: 1) No information could be found in open literature on acceptable levels of contamination in boxes and action levels for cleanup. If these are not available in closed publications the 2) Where possible, the decontamination methods identified should be tested and dose information recorded against each method to allow informed decisions on which is the optimum technique for a particular form of contamination. 3) Consideration should be given to utilisation of metrology options which have the lowest potential for exposure of operators. Preferred options, may be detection from the outside of boxes using hand-held or permanently located radiation detectors, or semi-intrusive methods such as air-ionisation readings which would require one-off installation of detectors in ductwork

  16. 16 CFR Figure 8 to Part 1203 - Apparatus for Test of Retention System Strength

    Science.gov (United States)

    2010-01-01

    ...—Apparatus for Test of Retention System Strength ER10MR98.008 ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Apparatus for Test of Retention System Strength 8 Figure 8 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT...

  17. The responsiveness of sensibility and strength tests in patients undergoing carpal tunnel decompression

    Directory of Open Access Journals (Sweden)

    Miller Leanne

    2011-10-01

    Full Text Available Abstract Background Several clinical measures of sensory and motor function are used alongside patient-rated questionnaires to assess outcomes of carpal tunnel decompression. However there is a lack of evidence regarding which clinical tests are most responsive to clinically important change over time. Methods In a prospective cohort study 63 patients undergoing carpal tunnel decompression were assessed using standardised clinician-derived and patient reported outcomes before surgery, at 4 and 8 months follow up. Clinical sensory assessments included: touch threshold with monofilaments (WEST, shape-texture identification (STI™ test, static two-point discrimination (Mackinnon-Dellon Disk-Criminator and the locognosia test. Motor assessments included: grip and tripod pinch strength using a digital grip analyser (MIE, manual muscle testing of abductor pollicis brevis and opponens pollicis using the Rotterdam Intrinsic Handheld Myometer (RIHM. The Boston Carpal Tunnel Questionnaire (BCTQ was used as a patient rated outcome measure. Results Relative responsiveness at 4 months was highest for the BCTQ symptom severity scale with moderate to large effects sizes (ES = -1.43 followed by the BCTQ function scale (ES = -0.71. The WEST and STI™ were the most responsive sensory tests at 4 months showing moderate effect sizes (WEST ES = 0.55, STI ES = 0.52. Grip and pinch strength had a relatively higher responsiveness compared to thenar muscle strength but effect sizes for all motor tests were very small (ES ≤0.10 or negative indicating a decline compared to baseline in some patients. Conclusions For clinical assessment of sensibility touch threshold assessed by monofilaments (WEST and tactile gnosis measured with the STI™ test are the most responsive tests and are recommended for future studies. The use of handheld myometry (RIHM for manual muscle testing, despite more specifically targeting thenar muscles, was less responsive than grip or tripod

  18. Test Results and Comparison of Triaxial Strength Testing of Waste Isolation Pilot Plant Clean Salt

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Stuart A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    This memorandum documents laboratory thermomechanical triaxial strength testing of Waste Isolation Pilot Plant (WIPP) clean salt. The limited study completed independent, adjunct laboratory tests in the United States to assist in validating similar testing results being provided by the German facilities. The testing protocol consisted of completing confined triaxial, constant strain rate strength tests of intact WIPP clean salt at temperatures of 25°C and 100°C and at multiple confining pressures. The stratigraphy at WIPP also includes salt that has been labeled “argillaceous.” The much larger test matrix conducted in Germany included both the so-called clean and argillaceous salts. When combined, the total database of laboratory results will be used to develop input parameters for models, assess adequacy of existing models, and predict material behavior. These laboratory studies are also consistent with the goals of the international salt repository research program. The goal of this study was to complete a subset of a test matrix on clean salt from the WIPP undertaken by German research groups. The work was performed at RESPEC in Rapid City, South Dakota. A rigorous Quality Assurance protocol was applied, such that corroboration provides the potential of qualifying all of the test data gathered by German research groups.

  19. Adhesion strength study of IBAD-MOCVD-based 2G HTS wire using a peel test

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Y., E-mail: yzhang@superpower-inc.com [SuperPower Inc., 450 Duane Avenue, Schenectady, NY 12304 (United States); Hazelton, D.W.; Knoll, A.R.; Duval, J.M.; Brownsey, P.; Repnoy, S.; Soloveichik, S.; Sundaram, A.; McClure, R.B. [SuperPower Inc., 450 Duane Avenue, Schenectady, NY 12304 (United States); Majkic, G.; Selvamanickam, V. [University of Houston, 4800 Calhoun Road, Houston, TX 77204 (United States)

    2012-02-15

    A peel test was used to study the adhesion strength of a commercial grade 2G HTS wire which features a characteristic multilayer structure with the rare earth-based MOCVD superconducting film deposited on an IBAD-MgO template. The peel test could be carried out at various peeling angles (from 90 Degree-Sign to 180 Degree-Sign) and the peel strength of a wire was defined as the steady-state peeling load determined from a load-displacement curve. The test results had good reproducibility and accuracy, making the test a reliable and useful method for studying the adhesion strength of the wire. By characterizing the peeled surfaces the weakest interface in a wire could be identified. The peel strength data of the wire was analyzed together with the performance of the experimental magnet coils fabricated using the wire. The effect of the silver contact layer annealing on the peel strength is discussed.

  20. Strength functions for fragmented doorway states

    International Nuclear Information System (INIS)

    MacDonald, W.M.

    1980-01-01

    Coupling a strongly excited ''doorway state'' to weak ''hallway states'' distributes its strength into micro-resonances seen in differential cross sections taken with very good energy resolution. The distribution of strength is shown to be revealed by reduced widths of the K-matrix rather than by the imaginary part of poles of the S-matrix. Different strength functions (SF) constructed by averaging the K-matrix widths are then investigated to determine their dependences on energy and on parameters related to averages of microscopic matrix elements. A new sum rule on the integrated strength of these SF is derived and used to show that different averaging procedures actually distribute the strength differently. Finally, it is shown that the discontinuous summed strength defines spreading parameters for the doorway state only in strong coupling, where it approximates the idefinite integral of the continuous SF of MacDonald-Mekjian-Kerman-De Toledo Piza. A new method of ''parametric continuation'' is used to relate a discontinuous sliding box-average, or a finite sum, of discrete terms to a continous function

  1. Accelerated Creep Testing of High Strength Aramid Webbing

    Science.gov (United States)

    Jones, Thomas C.; Doggett, William R.; Stnfield, Clarence E.; Valverde, Omar

    2012-01-01

    A series of preliminary accelerated creep tests were performed on four variants of 12K and 24K lbf rated Vectran webbing to help develop an accelerated creep test methodology and analysis capability for high strength aramid webbings. The variants included pristine, aged, folded and stitched samples. This class of webbings is used in the restraint layer of habitable, inflatable space structures, for which the lifetime properties are currently not well characterized. The Stepped Isothermal Method was used to accelerate the creep life of the webbings and a novel stereo photogrammetry system was used to measure the full-field strains. A custom MATLAB code is described, and used to reduce the strain data to produce master creep curves for the test samples. Initial results show good correlation between replicates; however, it is clear that a larger number of samples are needed to build confidence in the consistency of the results. It is noted that local fiber breaks affect the creep response in a similar manner to increasing the load, thus raising the creep rate and reducing the time to creep failure. The stitched webbings produced the highest variance between replicates, due to the combination of higher local stresses and thread-on-fiber damage. Large variability in the strength of the webbings is also shown to have an impact on the range of predicted creep life.

  2. Dentin-Composite Bond Strength Measurement Using the Brazilian Disk Test

    Science.gov (United States)

    Carrera, Carola A.; Chen, Yung-Chung; Li, Yuping; Rudney, Joel; Aparicio, Conrado; Fok, Alex

    2016-01-01

    Objectives This study presents a variant of the Brazilian disk test (BDT) for assessing the bond strength between composite resins and dentin. Methods Dentin-composite disks (φ 5 mm × 2 mm) were prepared using either Z100 or Z250 (3M ESPE) in combination with one of three adhesives, Adper Easy Bond (EB), Adper Scotchbond Multi-Purpose (MP) and Adper Single Bond (SB), and tested under diametral compression. Acoustic emission (AE) and digital image correlation (DIC) were used to monitor debonding of the composite from the dentin ring. A finite element (FE) model was created to calculate the bond strengths using the failure loads. Fracture modes were examined by scanning electron microscopy (SEM). Results Most specimens fractured along the dentin-resin composite interface. DIC and AE confirmed interfacial debonding immediately before fracture of the dentin ring. Results showed that the mean bond strength with EB (14.9±1.9 MPa) was significantly higher than with MP (13.2±2.4 MPa) or SB (12.9±3.0 MPa) (p0.05). Z100 (14.5±2.3 MPa) showed higher bond strength than Z250 (12.7±2.5 MPa) (padhesive failure mode. EB failed mostly at the dentin-adhesive interface, whereas MP at the composite-adhesive interface; specimens with SB failed at the composite-adhesive interface and cohesively in the adhesive. Conclusions The BDT variant showed to be a suitable alternative for measuring the bond strength between dentin and composite, with zero premature failure, reduced variability in the measurements, and consistent failure at the dentin-composite interface. PMID:27395367

  3. Characteristics of structural loess strength and preliminary framework for joint strength formula

    OpenAIRE

    Rong-jian Li; Jun-ding Liu; Rui Yan; Wen Zheng; Sheng-jun Shao

    2014-01-01

    The strength of structural loess consists of the shear strength and tensile strength. In this study, the stress path, the failure envelope of principal stress (Kf line), and the strength failure envelope of structurally intact loess and remolded loess were analyzed through three kinds of tests: the tensile strength test, the uniaxial compressive strength test, and the conventional triaxial shear strength test. Then, in order to describe the tensile strength and shear strength of structural lo...

  4. Relating wood properties to handsheet porosity and mechanical strength

    CSIR Research Space (South Africa)

    Maharaj, S

    2006-11-01

    Full Text Available , 4041 3CSIR, Forestry and Forest Products Research Centre, P.O. Box 17001, Congella, 4013 WOOD HAND-SHEET (STRENGTH) PROCESSING Anatomy Chemistry Density Tear Tensile Burst Background Variation in pulp mills •Need to predict quality of end... important concepts… Some important concepts… • Collapsibility and inter-fibre bonding Light Microscopy SEM • Tear – Fibre level: pull-out vs. breaking/rupture Some important concepts… •Fibre breakage / rupture: less energy = lower tear strength...

  5. Bond strength and microleakage of current dentin adhesives.

    Science.gov (United States)

    Fortin, D; Swift, E J; Denehy, G E; Reinhardt, J W

    1994-07-01

    The purpose of this in vitro study was to evaluate shear bond strengths and microleakage of seven current-generation dentin adhesive systems. Standard box-type Class V cavity preparations were made at the cemento-enamel junction on the buccal surfaces of eighty extracted human molars. These preparations were restored using a microfill composite following application of either All-Bond 2 (Bisco), Clearfil Liner Bond (Kuraray), Gluma 2000 (Miles), Imperva Bond (Shofu), OptiBond (Kerr), Prisma Universal Bond 3 (Caulk), Scotchbond Multi-Purpose (3M), or Scotchbond Dual-Cure (3M) (control). Lingual dentin of these same teeth was exposed and polished to 600-grit. Adhesives were applied and composite was bonded to the dentin using a gelatin capsule technique. Specimens were thermocycled 500 times. Shear bond strengths were determined using a universal testing machine, and microleakage was evaluated using a standard silver nitrate staining technique. Clearfill Liner Bond and OptiBond, adhesive systems that include low-viscosity, low-modulus intermediate resins, had the highest shear bond strengths (13.3 +/- 2.3 MPa and 12.9 +/- 1.5 MPa, respectively). Along with Prisma Universal Bond 3, they also had the least microleakage at dentin margins of Class V restorations. No statistically significant correlation between shear bond strength and microleakage was observed in this study. Adhesive systems that include a low-viscosity intermediate resin produced the high bond strengths and low microleakage. Similarly, two materials with bond strengths in the intermediate range had significantly increased microleakage, and one material with a bond strength in the low end of the spectrum exhibited microleakage that was statistically greater. Thus, despite the lack of statistical correlation, there were observable trends.

  6. Development of a new glove for glove boxes with high level performances

    International Nuclear Information System (INIS)

    Jerome Blancher; Jean-Marc Poirier

    2006-01-01

    This paper describes the results of a joint technological program of COGEMA and MAPA to develop a new generation of glove for glove boxes. The mechanical strength of this glove is twice as high as the best characteristics of gloves available on the market. This new generation of product has both a higher level of performance and better ergonomics. (authors)

  7. Development of a new glove for glove boxes with high level performances

    Energy Technology Data Exchange (ETDEWEB)

    Jerome Blancher [AREVA/COGEMA Recycling Business Unit, BP 94176 - 30204 Bagnols-sur-Ceze Cedex (France); Jean-Marc Poirier [MAPA SPONTEX, BP 190 - 92205 Neuilly sur Seine Cedex (France)

    2006-07-01

    This paper describes the results of a joint technological program of COGEMA and MAPA to develop a new generation of glove for glove boxes. The mechanical strength of this glove is twice as high as the best characteristics of gloves available on the market. This new generation of product has both a higher level of performance and better ergonomics. (authors)

  8. Dependency of Shear Strength on Test Rate in SiC/BSAS Ceramic Matrix Composite at Elevated Temperature

    Science.gov (United States)

    Choi, Sung R.; Bansal, Narottam P.; Gyekenyesi, John P.

    2003-01-01

    Both interlaminar and in-plane shear strengths of a unidirectional Hi-Nicalon(TM) fiber-reinforced barium strontium aluminosilicate (SiC/BSAS) composite were determined at 1100 C in air as a function of test rate using double notch shear test specimens. The composite exhibited a significant effect of test rate on shear strength, regardless of orientation which was either in interlaminar or in in-plane direction, resulting in an appreciable shear-strength degradation of about 50 percent as test rate decreased from 3.3 10(exp -1) mm/s to 3.3 10(exp -5) mm/s. The rate dependency of composite's shear strength was very similar to that of ultimate tensile strength at 1100 C observed in a similar composite (2-D SiC/BSAS) in which tensile strength decreased by about 60 percent when test rate varied from the highest (5 MPa/s) to the lowest (0.005 MPa/s). A phenomenological, power-law slow crack growth formulation was proposed and formulated to account for the rate dependency of shear strength of the composite.

  9. Clinical tests of ankle plantarflexor strength do not predict ankle power generation during walking.

    Science.gov (United States)

    Kahn, Michelle; Williams, Gavin

    2015-02-01

    The aim of this study was to investigate the relationship between a clinical test of ankle plantarflexor strength and ankle power generation (APG) at push-off during walking. This is a prospective cross-sectional study of 102 patients with traumatic brain injury. Handheld dynamometry was used to measure ankle plantarflexor strength. Three-dimensional gait analysis was performed to quantify ankle power generation at push-off during walking. Ankle plantarflexor strength was only moderately correlated with ankle power generation at push-off (r = 0.43, P < 0.001; 95% confidence interval, 0.26-0.58). There was also a moderate correlation between ankle plantarflexor strength and self-selected walking velocity (r = 0.32, P = 0.002; 95% confidence interval, 0.13-0.48). Handheld dynamometry measures of ankle plantarflexor strength are only moderately correlated with ankle power generation during walking. This clinical test of ankle plantarflexor strength is a poor predictor of calf muscle function during gait in people with traumatic brain injury.

  10. Orthodontic brackets removal under shear and tensile bond strength resistance tests – a comparative test between light sources

    International Nuclear Information System (INIS)

    Silva, P C G; Porto-Neto, S T; Lizarelli, R F Z; Bagnato, V S

    2008-01-01

    We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 ± 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased

  11. Taking into account seismic risk on glove boxes

    Energy Technology Data Exchange (ETDEWEB)

    Ladurelle, Marie; Philipponneau, Yannick

    2005-01-01

    Built in 1981, the LEFCA is a Basic Nuclear Facility (BNF) in which experimental plutonium based fuels are produced and characterised in about a hundred Gloves Boxes (GB). Many safety rules are required, especially those concerning seismic risk. In order to prepare the December 2003 safety reconsideration, the following methodology has been proposed so that GB might resist the Safe Shutdown Earthquake. 1) The determination of a safety target: the GB static containment. 2) The realisation of an ''in situ'' assessment: the definition of several classes of GB, vibrating table tests and the modelling of the GB behaviour with seismic solicitations, 3) A strength diagnosis for equipment: filters, connecting tunnels and pipes holding. 4) A proposal for further strengthening modifications if necessary : fixing the frame, interlocking GB and the frame, taking internal or external GB missiles into account. This process has contributed to a reduction in the radiological potential seismic impact for the neighbouring populations. We shall present the implemented methodology and the strengthening works that have been approved by Safety Authorities. Reinforcement modifications will begin in 2004. (Author)

  12. Taking into account seismic risk on glove boxes

    International Nuclear Information System (INIS)

    Ladurelle, Marie; Philipponneau, Yannick

    2005-01-01

    Built in 1981, the LEFCA is a Basic Nuclear Facility (BNF) in which experimental plutonium based fuels are produced and characterised in about a hundred Gloves Boxes (GB). Many safety rules are required, especially those concerning seismic risk. In order to prepare the December 2003 safety reconsideration, the following methodology has been proposed so that GB might resist the Safe Shutdown Earthquake. 1) The determination of a safety target: the GB static containment. 2) The realisation of an ''in situ'' assessment: the definition of several classes of GB, vibrating table tests and the modelling of the GB behaviour with seismic solicitations, 3) A strength diagnosis for equipment: filters, connecting tunnels and pipes holding. 4) A proposal for further strengthening modifications if necessary : fixing the frame, interlocking GB and the frame, taking internal or external GB missiles into account. This process has contributed to a reduction in the radiological potential seismic impact for the neighbouring populations. We shall present the implemented methodology and the strengthening works that have been approved by Safety Authorities. Reinforcement modifications will begin in 2004. (Author)

  13. Improving Your Data Transformations: Applying the Box-Cox Transformation

    Directory of Open Access Journals (Sweden)

    Jason W. Osborne

    2010-10-01

    Full Text Available Many of us in the social sciences deal with data that do not conform to assumptions of normality and/or homoscedasticity/homogeneity of variance. Some research has shown that parametric tests (e.g., multiple regression, ANOVA can be robust to modest violations of these assumptions. Yet the reality is that almost all analyses (even nonparametric tests benefit from improved the normality of variables, particularly where substantial non-normality is present. While many are familiar with select traditional transformations (e.g., square root, log, inverse for improving normality, the Box-Cox transformation (Box & Cox, 1964 represents a family of power transformations that incorporates and extends the traditional options to help researchers easily find the optimal normalizing transformation for each variable. As such, Box-Cox represents a potential best practice where normalizing data or equalizing variance is desired. This paper briefly presents an overview of traditional normalizing transformations and how Box-Cox incorporates, extends, and improves on these traditional approaches to normalizing data. Examples of applications are presented, and details of how to automate and use this technique in SPSS and SAS are included.

  14. Medical and Safety Reforms in Boxing

    Science.gov (United States)

    Jordan, Barry D.

    1988-01-01

    The continued existence of boxing as an accepted sport in civilized society has been long debated. The position of the American Medical Association (AMA) has evolved from promoting increased safety and medical reform to recommending total abolition of both amateur and professional boxing. In response to the AMA opposition to boxing, the boxing community has attempted to increase the safeguards in amateur and professional boxing. The United States of America Amateur Boxing Federation, which is the national regulatory agency for all amateur boxing in the United States, has taken several actions to prevent the occurrence of acute brain injury and is currently conducting epidemiologic studies to assess the long-term neuropsychologic consequences of amateur boxing. In professional boxing, state regulatory agencies such as the New York State Athletic Commission have introduced several medical interventions to prevent and reduce neurologic injury. The lack of a national regulatory agency to govern professional boxing has stimulated the formation of the Association of Boxing Commissions and potential legislation for the federal regulation of professional boxing by a federally chartered organization called the United States Boxing Commission. The AMA's opposition to boxing and the medical and safety reforms implemented by the proponents of boxing are discussed. PMID:3385788

  15. Study of Randomness in AES Ciphertexts Produced by Randomly Generated S-Boxes and S-Boxes with Various Modulus and Additive Constant Polynomials

    Science.gov (United States)

    Das, Suman; Sadique Uz Zaman, J. K. M.; Ghosh, Ranjan

    2016-06-01

    In Advanced Encryption Standard (AES), the standard S-Box is conventionally generated by using a particular irreducible polynomial {11B} in GF(28) as the modulus and a particular additive constant polynomial {63} in GF(2), though it can be generated by many other polynomials. In this paper, it has been shown that it is possible to generate secured AES S-Boxes by using some other selected modulus and additive polynomials and also can be generated randomly, using a PRNG like BBS. A comparative study has been made on the randomness of corresponding AES ciphertexts generated, using these S-Boxes, by the NIST Test Suite coded for this paper. It has been found that besides using the standard one, other moduli and additive constants are also able to generate equally or better random ciphertexts; the same is true for random S-Boxes also. As these new types of S-Boxes are user-defined, hence unknown, they are able to prevent linear and differential cryptanalysis. Moreover, they act as additional key-inputs to AES, thus increasing the key-space.

  16. Glove box

    International Nuclear Information System (INIS)

    Morita, Atsushi

    1990-01-01

    Wire rope earthquake proof supports having sufficient vibration transmitting and attenuating property are disposed between a fixed floor and the bottom of a glove box in order to improve earthquake proofness of the glove box. The vertical weight of the glove box is supported by support legs slidable on the surface of the fixed floor. The wire rope earthquake-proof supports when undergoing a load, cause stretching and rolling against the external force such as earthquakes, and provide flexible spring support and cause a great damping due to friction with strands. Further, the vertical weight is always supported by the support legs and, when a horizontal weight is applied, the glove box slides on the fixed floor freely with slidable members. In this way, stress concentration generated at joint portions of columns and beams can be moderated greatly and earthquake proofness can be improved. Further, quality control and maintenance for the device is almost unnecessary owing to excellent fatigue-resistant characteristics of the wire rope earthquake proof supports. (N.H.)

  17. Milestone 5 test report. Task 5, subtask 5.2: Tile to foam strength tests

    Science.gov (United States)

    Greenberg, H. S.

    1994-01-01

    This report summarizes work that has been performed to date on the strength of a cryotank insulation system using Rohacell foam and TUFI-coated AETB-12 ceramic tiles directly bonded to a simulated graphite-epoxy tank wall. Testing utilized a custom specimen design which consists of a long tensile specimen with eccentric loading to induce curvature similar to the curvature expected due to 'pillowing' of the tank when pressurized. A finite element model was constructed to predict the specific element strains in the test article, and to assist with design of the test specimen to meet the specific goals of curvature and laminate strain. The results indicate that the heat treated 3.25-pcf density Rohacell foam does not provide sufficient strength for the induced stresses due to curvature and stress concentration at the RTV bondline to the TUFI tile. The test was repeated using higher density non-heat treated Rohacell foam (6.9 pcf) without foam failure. The finite element model was shown to predict specimen behavior, and validation of the model was successful. It is pertinent to mention that the analyses described herein accurately predicted the failure of the heat treated foams and based on this analysis method it is expected that the untreated 3.25 pcf Rohacell foam will be successful.

  18. The puzzle box as a simple and efficient behavioral test for exploring impairments of general cognition and executive functions in mouse models of schizophrenia.

    Science.gov (United States)

    Ben Abdallah, Nada M-B; Fuss, Johannes; Trusel, Massimo; Galsworthy, Michael J; Bobsin, Kristin; Colacicco, Giovanni; Deacon, Robert M J; Riva, Marco A; Kellendonk, Christoph; Sprengel, Rolf; Lipp, Hans-Peter; Gass, Peter

    2011-01-01

    Deficits in executive functions are key features of schizophrenia. Rodent behavioral paradigms used so far to find animal correlates of such deficits require extensive effort and time. The puzzle box is a problem-solving test in which mice are required to complete escape tasks of increasing difficulty within a limited amount of time. Previous data have indicated that it is a quick but highly reliable test of higher-order cognitive functioning. We evaluated the use of the puzzle box to explore executive functioning in five different mouse models of schizophrenia: mice with prefrontal cortex and hippocampus lesions, mice treated sub-chronically with the NMDA-receptor antagonist MK-801, mice constitutively lacking the GluA1 subunit of AMPA-receptors, and mice over-expressing dopamine D2 receptors in the striatum. All mice displayed altered executive functions in the puzzle box, although the nature and extent of the deficits varied between the different models. Deficits were strongest in hippocampus-lesioned and GluA1 knockout mice, while more subtle deficits but specific to problem solving were found in the medial prefrontal-lesioned mice, MK-801-treated mice, and in mice with striatal overexpression of D2 receptors. Data from this study demonstrate the utility of the puzzle box as an effective screening tool for executive functions in general and for schizophrenia mouse models in particular. Published by Elsevier Inc.

  19. A novel method to design S-box based on chaotic map and genetic algorithm

    International Nuclear Information System (INIS)

    Wang, Yong; Wong, Kwok-Wo; Li, Changbing; Li, Yang

    2012-01-01

    The substitution box (S-box) is an important component in block encryption algorithms. In this Letter, the problem of constructing S-box is transformed to a Traveling Salesman Problem and a method for designing S-box based on chaos and genetic algorithm is proposed. Since the proposed method makes full use of the traits of chaotic map and evolution process, stronger S-box is obtained. The results of performance test show that the presented S-box has good cryptographic properties, which justify that the proposed algorithm is effective in generating strong S-boxes. -- Highlights: ► The problem of constructing S-box is transformed to a Traveling Salesman Problem. ► We present a new method for designing S-box based on chaos and genetic algorithm. ► The proposed algorithm is effective in generating strong S-boxes.

  20. A novel method to design S-box based on chaotic map and genetic algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yong, E-mail: wangyong_cqupt@163.com [State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400044 (China); Key Laboratory of Electronic Commerce and Logistics, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China); Wong, Kwok-Wo [Department of Electronic Engineering, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon Tong (Hong Kong); Li, Changbing [Key Laboratory of Electronic Commerce and Logistics, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China); Li, Yang [Department of Automatic Control and Systems Engineering, The University of Sheffield, Mapping Street, S1 3DJ (United Kingdom)

    2012-01-30

    The substitution box (S-box) is an important component in block encryption algorithms. In this Letter, the problem of constructing S-box is transformed to a Traveling Salesman Problem and a method for designing S-box based on chaos and genetic algorithm is proposed. Since the proposed method makes full use of the traits of chaotic map and evolution process, stronger S-box is obtained. The results of performance test show that the presented S-box has good cryptographic properties, which justify that the proposed algorithm is effective in generating strong S-boxes. -- Highlights: ► The problem of constructing S-box is transformed to a Traveling Salesman Problem. ► We present a new method for designing S-box based on chaos and genetic algorithm. ► The proposed algorithm is effective in generating strong S-boxes.

  1. Safety evaluation for packaging (onsite) depleted uranium waste boxes

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, W.A.

    1997-08-27

    This safety evaluation for packaging (SEP) allows the one-time shipment of ten metal boxes and one wooden box containing depleted uranium material from the Fast Flux Test Facility to the burial grounds in the 200 West Area for disposal. This SEP provides the analyses and operational controls necessary to demonstrate that the shipment will be safe for the onsite worker and the public.

  2. Safety evaluation for packaging (onsite) depleted uranium waste boxes

    International Nuclear Information System (INIS)

    McCormick, W.A.

    1997-01-01

    This safety evaluation for packaging (SEP) allows the one-time shipment of ten metal boxes and one wooden box containing depleted uranium material from the Fast Flux Test Facility to the burial grounds in the 200 West Area for disposal. This SEP provides the analyses and operational controls necessary to demonstrate that the shipment will be safe for the onsite worker and the public

  3. Reliability of isometric subtalar pronator and supinator strength testing.

    Science.gov (United States)

    Hagen, Marco; Lahner, Matthias; Winhuysen, Martin; Maiwald, Christian

    2015-01-01

    Due to the specific anatomy of the subtalar joint with its oblique axis, isometric pronator and supinator strength is not well documented. The purpose of this study was to determine intra- and between-session reliability of pronator and supinator strength and lower leg muscle activity measurements during maximum voluntary isometric contractions (MVIC). Pronator and supinator peak torques (PT), with and without supplementary visual muscle strength biofeedback (FB), and muscular activities of peroneus longus (PL) and tibialis anterior (TA) were assessed twice 3 days apart by the same examiner in 21 healthy young male adults (mean age: 27.6 years; SD = 3.9). Limits of agreement (LoA) and minimum detectable change (MDC) were evaluated. By applying FB, reliability of both pronator and supinator PT was improved: LoA were reduced from 32% to 26% and from 20% to 18% and MDC from 20% to 15% and from 16% to 12% in supinator and pronator PT, respectively. Learning effects in pronator and supinator PT (p isometric subtalar pronator and supinator strength testing is reliable in healthy subjects. LoA of 18% and 26% have to be exceeded for pronator and supinator PT, respectively, to detect relevant effects in repeated measures.

  4. Porosimetric, Thermal and Strength Tests of Aerated and Nonaerated Concretes

    Science.gov (United States)

    Strzałkowski, Jarosław; Garbalińska, Halina

    2017-10-01

    The paper presents the results of porosimetry tests of lightweight concretes, obtained with three research methods. Impact of different porosity structures on the basic thermal and strength properties was also evaluated. Tests were performed, using the pressure gauge method on fresh concrete mixes, as well as using the mercury porosimetry test and optic RapidAir method on specimens prepared from mature composites. The study was conducted on lightweight concretes, based on expanded clay aggregate and fly ash aggregate, in two variants: with non-aerated and aerated cement matrix. In addition, two reference concretes, based on normal aggregate, were prepared, also in two variants of matrix aeration. Changes in thermal conductivity λ and volumetric specific heat cv throughout the first three months of curing of the concretes were examined. Additionally, tests for compressive strength on cubic samples were performed during the first three months of curing. It was found that the pressure gauge method, performed on a fresh mix, gave lowered values of porosity, compared to the other methods. The mercury porosity tests showed high sensitivity in evaluation of pores smaller than 30μm. Unfortunately, this technique is not suitable for analysing pores greater than 300μm. On the other hand, the optical method proves good in evaluation of large pores, greater than 300μm. The paper also presents results of correlation of individual methods of porosity testing. A consolidated graph of the pore structure, derived from both mercury and optical methods, was presented, too. For the all of six tested concretes, differential graphs of porosity, prepared with both methods, show a very broad convergence. The thermal test results indicate usefulness of aeration of the cement matrix of the composites based on lightweight aggregates for the further reduction of the thermal conductivity coefficient λ of the materials. The lowest values of the λ coefficient were obtained for the aerated

  5. Bento Boxes

    Science.gov (United States)

    Hasio, Cindy

    2010-01-01

    Bento boxes are common objects in Japanese culture, designed to hold enough lunch for one person. They have individual compartments and sometimes multiple tiers for rice, vegetables, and other side dishes. They are made of materials ranging from wood, cloth, aluminum, or plastic. In general, the greater the number of foods, the better the box is…

  6. Fatigue behavior of boxing welded joint under biaxial cyclic loads; 2juku kurikaeshi kajuka ni okeru kakumawashi yosetsu keishu no hiro kyodo

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, I.; Takada, A.; Akiyama, S.; Ushijima, M.; Maenaka, H. [Ministry of Transportation, Tokyo (Japan)

    1998-12-31

    Various forces such as gravity, wave induced force, inertial force etc. compositely act on a ship body from various directions. Therefore, while discussing strength or life of structural elements of ship body, it is necessary to understand the effects of the composite force condition. In this study, fatigue tests of boxing welded joint under rectangular biaxial cyclic loads are performed, the following results are obtained. Even under he biaxial cyclic loads, it is the same as the uniaxial test, the cracks occurred at the boxing weld toes propagate almost in the straight y-direction, but no oblique propagation of the cracks caused by the lad in the y-direction occurs. That the crack at initial stage of the crack progress is improved in y-direction can be illustrated by the facts that the residual stress in x-direction near the toes reaches to the yield stress, and the stress concentration in the welded toes is bigger in x-direction than that in y-direction. But as for prediction of the progress route, a further study including amplitude ratio of the biaxial loads, effects of width of test specimen is necessary. 4 refs., 12 figs., 4 tabs.

  7. Bond strength tests between silicon wafers and duran tubes (fusion bonded fluidic interconnects)

    NARCIS (Netherlands)

    Fazal, I.; Berenschot, Johan W.; de Boer, J.H.; Jansen, Henricus V.; Elwenspoek, Michael Curt

    2005-01-01

    The fusion bond strength of glass tubes with standard silicon wafers is presented. Experiments with plain silicon wafers and those coated with silicon oxide and silicon nitride are presented. Results obtained are discussed in terms of homogeneity and strength of fusion bond. High pressure testing

  8. The Construction of a Muscular Strength Test Battery for Girls in the Primary Grades.

    Science.gov (United States)

    DiNucci, James M.; Pelton, Elois B.

    This study was designed to construct a gross muscular strength test battery for girls 6-9 years of age in grades 1-3. The subjects for this investigation were a random sample of 183 girls in grades 1-3 of the public schools of Natchitoches, Louisiana. The variables selected were 22 cable tension strength tests developed by Clarke and associates.…

  9. Influence of Specimen Preparation and Test Methods on the Flexural Strength Results of Monolithic Zirconia Materials.

    Science.gov (United States)

    Schatz, Christine; Strickstrock, Monika; Roos, Malgorzata; Edelhoff, Daniel; Eichberger, Marlis; Zylla, Isabella-Maria; Stawarczyk, Bogna

    2016-03-09

    The aim of this work was to evaluate the influence of specimen preparation and test method on the flexural strength results of monolithic zirconia. Different monolithic zirconia materials (Ceramill Zolid (Amann Girrbach, Koblach, Austria), Zenostar ZrTranslucent (Wieland Dental, Pforzheim, Germany), and DD Bio zx² (Dental Direkt, Spenge, Germany)) were tested with three different methods: 3-point, 4-point, and biaxial flexural strength. Additionally, different specimen preparation methods were applied: either dry polishing before sintering or wet polishing after sintering. Each subgroup included 40 specimens. The surface roughness was assessed using scanning electron microscopy (SEM) and a profilometer whereas monoclinic phase transformation was investigated with X-ray diffraction. The data were analyzed using a three-way Analysis of Variance (ANOVA) with respect to the three factors: zirconia, specimen preparation, and test method. One-way ANOVA was conducted for the test method and zirconia factors within the combination of two other factors. A 2-parameter Weibull distribution assumption was applied to analyze the reliability under different testing conditions. In general, values measured using the 4-point test method presented the lowest flexural strength values. The flexural strength findings can be grouped in the following order: 4-point strength values than prepared before sintering. The Weibull moduli ranged from 5.1 to 16.5. Specimens polished before sintering showed higher surface roughness values than specimens polished after sintering. In contrast, no strong impact of the polishing procedures on the monoclinic surface layer was observed. No impact of zirconia material on flexural strength was found. The test method and the preparation method significantly influenced the flexural strength values.

  10. SSL/TLS Vulnerability Detection Using Black Box Approach

    Science.gov (United States)

    Gunawan, D.; Sitorus, E. H.; Rahmat, R. F.; Hizriadi, A.

    2018-03-01

    Socket Secure Layer (SSL) and Transport Layer Security (TLS) are cryptographic protocols that provide data encryption to secure the communication over a network. However, in some cases, there are vulnerability found in the implementation of SSL/TLS because of weak cipher key, certificate validation error or session handling error. One of the most vulnerable SSL/TLS bugs is heartbleed. As the security is essential in data communication, this research aims to build a scanner that detect the SSL/TLS vulnerability by using black box approach. This research will focus on heartbleed case. In addition, this research also gathers information about existing SSL in the server. The black box approach is used to test the output of a system without knowing the process inside the system itself. For testing purpose, this research scanned websites and found that some of the websites still have SSL/TLS vulnerability. Thus, the black box approach can be used to detect the vulnerability without considering the source code and the process inside the application.

  11. 2D AND 3D KINEMATICS DURING LATERAL STEP-DOWN TESTING IN INDIVIDUALS WITH ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION.

    Science.gov (United States)

    Mostaed, Maria F; Werner, David M; Barrios, Joaquin A

    2018-02-01

    The lateral step-down test is an established clinical evaluation tool to assess quality of movement in patients with knee disorders. However, this test has not been investigated in individuals after anterior cruciate ligament reconstruction (ACLR) in association with quantitative 3D motion analysis. The purpose of this study was to determine the strength of association between visually-assessed quality of movement during the lateral step-down test and 3D lower limb kinematics in patients with history of ACLR. A second purpose was to compare kinematics between subgroups based on the presence or absence of faulty alignments during the task. The final purpose was to compare visually-assessed quality of movement scores between box heights during lateral step-down testing. Twenty subjects at least one year status post-ACLR (18 females, age of 24.5 ± 4.6 years and body mass index of 23.4 ± 2.3 kg/m 2 ) performed the lateral step-down test unilaterally on the surgical limb atop four and six inch boxes. A board-certified orthopedic physical therapist scored overall quality of movement during the lateral step-down test using established criteria during 2D video playback. Lower limb kinematics were simultaneously collected using 3D motion capture. An alpha level of 0.05 was used for all statistical treatments. Overall 2D quality of movement score significantly correlated (r =0.47-0.57) with 3D hip adduction and hip internal rotation across box heights. Across box heights, the presence of faulty pelvic alignment differentiated a subgroup exhibiting less peak knee flexion, and the presence of faulty knee alignment differentiated a subgroup exhibiting greater peak hip adduction. The six inch box elicited worse quality of movement compared to the four inch box. These results suggest that visually-assessed quality of movement is associated with several kinematic variables after ACLR. 2D movement deviations at the pelvis appear to consistently relate to less knee

  12. A curved beam test specimen for determining the interlaminar tensile strength of a laminated composite

    Science.gov (United States)

    Hiel, Clement C.; Sumich, Mark; Chappell, David P.

    1991-01-01

    A curved beam type of test specimen is evaluated for use in determining the through-the-thickness strength of laminated composites. Two variations of a curved beam specimen configuration (semicircular and elliptical) were tested to failure using static and fatigue loads. The static failure load for the semicircular specimens was found to be highly sensitive to flaw content, with the specimens falling into two distinct groups. This result supports the use of proof testing for structural validation. Static design allowables are derived based on the Weibull distribution. Fatigue data indicates no measured increase in specimen compliance prior to final fracture. All static and fatigue failures at room temperature dry conditions occurred catastrophically. The elliptical specimens demonstrated unusually high failure strengths indicating the presence of phenomena requiring further study. Results are also included for specimens exposed to a wet environment showing a matrix strength degradation due to moisture content. Further testing is underway to evaluate a fatigue methodology for matrix dominated failures based on residual static strength (wearout).

  13. Bleed water testing program for controlled low strength material

    International Nuclear Information System (INIS)

    Langton, C.A.

    1996-01-01

    Bleed water measurements for two Controlled Low Strength Material (CLSM) mixes were conducted to provide engineering data for the Tank 20F closure activities. CLSM Mix 1 contained 150 pounds of cement per cubic yard whereas CLSM Mix 2 contained 50 pounds per cub yard. SRS currently used CLSM Mix 2 for various applications. Bleed water percentages and generation rates were measured along with flow and compressive strength. This information will be used to select a mix design for the Tank 20F closure activities and to establish the engineering requirements, such as, lift height, time required between lifts and quantity of bleed water to be removed from the tank during the placement activities. Mix 1 is recommended for placement within Tank 20F because it has better flow characteristics, less segregation, lower percentage of bleed water and slightly higher strength. Optimization of Mix 1 was beyond the scope of this study. However, further testing of thickening additives, such as clays (bentonite), sodium silicate or fine silicas maybe useful for decreasing or eliminating bleed water

  14. Study on strength of thick reinforced concrete slab with opening - Part 2: Evaluation of the test results

    International Nuclear Information System (INIS)

    Hirai, T.; Itoh, M.; Takei, K.; Kanazu, T.; Abe, Y.; Takahashi, T.; Hayashi, N.; Sasaki, N.

    1993-01-01

    In comparing the strength of the partial models obtained from the test and the strength calculated by the various formulas for short span cantilevers based on recent research, it was found that the strength of the partial models coincided well with the calculated bending strength. It was confirmed that bending failure also preceded in the overall model from the tests. However various strengths such as the cracking strength and the yielding strength of rebars were larger, and displacements and strains in various parts were smaller than those in the partial models. It was attributed to the effects of circumferential distribution of the load. A convenient method was proposed for evaluation of the strength of the overall model. In this method, the overall model is divided into corbels, and the strength of the model is calculated as the sum of these corbels' strength. This method estimated the strength conveniently and conservatively. (author)

  15. Safety analysis report for packaging: DOT-7A fiberglass-coated plywood box for transuranium solid waste

    International Nuclear Information System (INIS)

    Adcock, F.E.; Cash, C.L.

    1976-01-01

    A DOT Specification 7A, fiberglass-coated plywood box for shipping alpha-emitting transuranic waste has been developed. Nominal size for the box is 4 by 4 by 7 ft; maximum gross weight is 5000 lb. Construction is of 3 / 4 -in. plywood with internal framing members of 2- by 4-in. lumber. The entire box, including the glued and nailed lid, is covered with a 0.12-in.-thick fiberglass coating. The required four-foot drop tests were passed without the box being damaged. Additional drops from 12 ft resulted in some cracking in a 2600-lb box and in cracking plus some loss of contents in a test box loaded to 5700 lb. A static load of 25,000 lb caused no deformation or damage. This box costs $3.50/ft 3 , which is approximately half the cost of steel drums with rigid polyethylene liners

  16. Quantifying the Physical Response to a Contemporary Amateur Boxing Simulation.

    Science.gov (United States)

    Finlay, Mitchell J; Greig, Matt; Page, Richard M

    2018-04-01

    Finlay, MJ, Greig, M, and Page, RM. Quantifying the physical response to a contemporary amateur boxing simulation. J Strength Cond Res 32(4): 1005-1012, 2018-This study examined the physical response to a contemporary boxing-specific exercise protocol (BSEP), based on notational analysis of amateur boxing. Nine male senior elite amateur boxers completed a 3 × 3-minute BSEP, with a 1-minute passive recovery period interspersing each round. Average (HRave) and peak (HRpeak) heart rates, average (V[Combining Dot Above]O2ave) and peak oxygen consumptions (V[Combining Dot Above]O2peak), blood lactate (BLa) concentrations, rating of perceived exertion, and both triaxial and uniaxial PlayerLoad metrics were recorded during the completion of the BSEP. Blood lactate concentration increased significantly in each round (Round 1 = 2.4 ± 1.3 mmol·L; Round 2 = 3.3 ± 1.7 mmol·L; Round 3 = 4.3 ± 2.6 mmol·L). Significantly lower HRave and HRpeak values were found in the first round (HRave: 150 ± 15 b·min; HRpeak: 162 ± 12 b·min) when compared with the second (HRave: 156 ± 16 b·min; HRpeak: 166 ± 13 b·min) and third (HRave: 150 ± 15 b·min; HRpeak: 169 ± 14 b·min). No significant differences were found in any of the V[Combining Dot Above]O2 or PlayerLoad metrics recorded during the BSEP. The BSEP based on notational analysis elicited a fatigue response across rounds, confirming its validity. The BSEP can be used as a training tool for boxing-specific conditioning with implications for reduced injury risk, and to assess the physical response to boxing-specific interventions. Moreover, the BSEP can also be manipulated to suit all levels of participants or training phases, with practical applications in performance monitoring and microcycle periodization.

  17. C-130: Results of center wing residual strength and crack propagation test program

    Science.gov (United States)

    Reeder, F. L.; Dirkin, W. J.; Snider, H. L.

    1971-01-01

    Fourteen C-130 airplane center wings which had experienced from approximately 4,000 to 13,000 hours of flight service and its associated fatigue damage were tested to destruction, seven in upbending and seven in downbending. Six wings were tested directly for static residual strength in the fatigue-damaged condition as received from field service. The other eight wings were tested in crack propagation cyclic testing at a prescribed stress level for a maximum of 10,000 cycles. Then the stress level was reduced and testing was continued up to a maximum of 20,000 total cycles. Cyclic testing was performed with constant-amplitude stresses at a stress ratio of +0.1. Maximum cyclic skin stresses were approximately 18,000 psi. At the conclusion of cyclic testing, a static test to destruction was conducted to determine the residual strength of each fatigue-damaged specimen.

  18. Adhesion strength of Ni film on Ti substrate characterized by three-point bend test, peel test and theoretic calculation

    International Nuclear Information System (INIS)

    Ren, F.Z.; Liu, P.; Jia, S.G.; Tian, B.H.; Su, J.H.

    2006-01-01

    Electroplating was employed to fabricate the Ni film on the Ti substrate. Adhesion strength of Ni film on Ti substrate was determined using the three-point bend technique that was proposed in standard mechanics test. The experimental results demonstrate that the interface fracture energies obviously increase with the roughness of Ti substrates, and are independence with the thickness of Ni films. Moreover, the adhesion strength of Ni film on Ti substrate was also measured by peel test, and was evaluated by Miedema model of experiential electron theory. The intrinsic interface fracture energy measured by three-point bend test is reasonable agreement with that obtained by theoretical calculation of Miedema model, and is roughly comparable to that by peel test

  19. Changes in position and quality of preferred nest box: effects on nest box use by laying hens

    DEFF Research Database (Denmark)

    Riber, Anja Brinch; Nielsen, Birte L.

    2013-01-01

    Using laying hens, we investigated whether position of a nest box, both within the pen and relative to other nest boxes, influenced the preference for a nest box, and how a sudden and marked change to the preferred box influenced the use of nest boxes by the hens. Groups (n=12) of 15 Isa Warren...... hens were housed in pens, each with five identical nest boxes in different positions: Two single (in a corner or not) and a triplet of nest boxes (one of which in a corner). The use of nest boxes was determined by the number of eggs laid daily in each box. Three experiments, each lasting 10 days, were...... carried out. First, the undisturbed use of each of the nest box types was investigated, and a strong preference (Peggs laid there. Second, each of the hen groups was moved to another pen allocated at random, and where...

  20. [Boxing: traumatology and prevention].

    Science.gov (United States)

    Cabanis, Emmanuel-Alain; Iba-Zizen, Marie-Thérèse; Perez, Georges; Senegas, Xavier; Furgoni, Julien; Pineau, Jean-Claude; Louquet, Jean-Louis; Henrion, Roger

    2010-10-01

    In 1986, a surgeon who, as an amateur boxer himself was concerned with boxers' health, approached a pioneering Parisian neuroimaging unit. Thus began a study in close cooperation with the French Boxing Federation, spanning 25 years. In a first series of 52 volunteer boxers (13 amateurs and 39 professionals), during which MRI gradually replaced computed tomography, ten risk factors were identified, which notably included boxing style: only one of 40 "stylists" with a good boxing technique had cortical atrophy (4.5 %), compared to 15 % of "sloggers". Changes to the French Boxing Federation rules placed the accent on medical prevention. The second series, of 247 boxers (81 amateurs and 266 professionals), showed a clear improvement, as lesions were suspected in 14 individuals, of which only 4 (1.35 %) were probably due to boxing. The third and fourth series were part of a protocol called "Brain-Boxing-Ageing", which included 76 boxers (11 having suffered KOs) and 120 MRI scans, with reproducible CT and MRI acquisitions (9 sequences with 1.5 T then 3 T, and CT). MRI anomalies secondary to boxing were found in 11 % of amateurs and 38 % of professionals (atrophy, high vascular T2 signal areas, 2 cases of post-KO subdural bleeding). CT revealed sinus damage in 13 % of the amateurs and 19 % of the professionals. The risk of acute and chronic facial and brain damage was underline, along with detailed precautionary measures (organization of bouts, role of the referee and ringside doctor, and application of French Boxing Federation rules).

  1. A new box system for a high pressure tritium pump

    International Nuclear Information System (INIS)

    Wilson, S.W.; Borree, R.J.; Chambers, D.I.; Souers, P.C.; Merrill, J.T.; Wiggins, R.K.

    1988-01-01

    A 200 MPa (30 kpsi) high pressure tritium pump inside a box system is described. This system is currently under construction but all representative mechanical parts have been fabricated and tested. The pump is a conventional mechanical-plus-cryostaged system, so that most of the interesting features are in the box. The system contains nine separate sections, with automatic pressure balancing and venting systems. Five sections are hood-to-box convertible enclosures with inflatable door seals. The procedure of cryostaging with liquid argon is described. Special detail is given to valves and motor shaft seals. 3 refs., 4 figs

  2. Effect of test temperature on the fatigue strength of the 12GN2MFAYu tempered steel

    International Nuclear Information System (INIS)

    Goritskij, V.M.; Terent'ev, V.F.; Bobyleva, L.A.

    1979-01-01

    The cyclic strength, variation of dislocation structure and fractography of specimen fractures were investigated depending on testing temperature. The specimens were tested at temperatures of 20, 350, 450, 550 deg C. The increase of testing temperature, according to the experimental data obtained, is accompanied by an insignificant reduction of fatigue strength. The testing temperature in the range from 350 to 550 deg C has a weak effect on the fatigue strength of the quenched and tempered steel. A change in the dislocation structure occurs under all tested temperatures in the 12 GN2MFAYu steel during fatigue. The intensity of the rearrangement of dislocation structure increases as the testing temperature increases to 550 deg C causing a decrease of the limited life-time at increased stress amplitudes

  3. A novel method of S-box design based on chaotic map and composition method

    International Nuclear Information System (INIS)

    Lambić, Dragan

    2014-01-01

    Highlights: • Novel chaotic S-box generation method is presented. • Presented S-box has better cryptographic properties than other examples of chaotic S-boxes. • The advantages of the proposed method are the low complexity and large key space. -- Abstract: An efficient algorithm for obtaining random bijective S-boxes based on chaotic maps and composition method is presented. The proposed method is based on compositions of S-boxes from a fixed starting set. The sequence of the indices of starting S-boxes used is obtained by using chaotic maps. The results of performance test show that the S-box presented in this paper has good cryptographic properties. The advantages of the proposed method are the low complexity and the possibility to achieve large key space

  4. Fusion welded fabrication of unshielded steel glove boxes

    International Nuclear Information System (INIS)

    1981-04-01

    This Specification deals with the manufacture, testing, inspection and delivery of fabricated glove boxes, including such internal and/or external fittings as are shown on the relevant drawings. (author)

  5. Reproducibility of the Internal Load and Performance-Based Responses to Simulated Amateur Boxing.

    Science.gov (United States)

    Thomson, Edward D; Lamb, Kevin L

    2017-12-01

    Thomson, ED and Lamb, KL. Reproducibility of the internal load and performance-based responses to simulated amateur boxing. J Strength Cond Res 31(12): 3396-3402, 2017-The aim of this study was to examine the reproducibility of the internal load and performance-based responses to repeated bouts of a three-round amateur boxing simulation protocol (boxing conditioning and fitness test [BOXFIT]). Twenty-eight amateur boxers completed 2 familiarization trials before performing 2 complete trials of the BOXFIT, separated by 4-7 days. To characterize the internal load, mean (HRmean) and peak (HRpeak) heart rate, breath-by-breath oxygen uptake (V[Combining Dot Above]O2), aerobic energy expenditure, excess carbon dioxide production (CO2excess), and ratings of perceived exertion were recorded throughout each round, and blood lactate determined post-BOXFIT. Additionally, an indication of the performance-based demands of the BOXFIT was provided by a measure of acceleration of the punches thrown in each round. Analyses revealed there were no significant differences (p > 0.05) between repeated trials in any round for all dependent measures. The typical error (coefficient variation %) for all but 1 marker of internal load (CO2excess) was 1.2-16.5% and reflected a consistency that was sufficient for the detection of moderate changes in variables owing to an intervention. The reproducibility of the punch accelerations was high (coefficient of variance % range = 2.1-2.7%). In general, these findings suggest that the internal load and performance-based efforts recorded during the BOXFIT are reproducible and, thereby, offer practitioners a method by which meaningful changes impacting on performance could be identified.

  6. Tests for determining impact resistance and strength of glass used for nuclear waste disposal

    International Nuclear Information System (INIS)

    Bunnell, L.R.

    1979-05-01

    Tests are described for determining the impact resistance (Section A) and static tensile strength (Section B) of glasses containing simulated or actual nuclear wastes. This report describes the development and use of these tests to rank different glasses, to assess effects of devitrification, and to examine the effect of impact energy on resulting surface area. For clarity this report is divided into two sections, Impact Resistance and Tensile Strength

  7. Electromyography Activation Levels of the 3 Gluteus Medius Subdivisions During Manual Strength Testing

    DEFF Research Database (Denmark)

    Otten, Roald; Tol, Johannes L; Holmich, Per

    2015-01-01

    deficits and guide specific rehabilitation programs. However, the optimal positions for assessing the strength and activation of these subdivisions are unknown. OBJECTIVE: The first aim was to establish which strength-testing positions produce the highest surface electromyography (sEMG) activation levels...... of the individual GM subdivisions. The second aim was to evaluate differences in sEMG activation levels between the tested and contralateral (stabilizing) leg. METHOD: Twenty healthy physically active male subjects participated in this study. Muscle activity using sEMG was recorded for the GM subdivisions in 8......STUDY DESIGN: Cross-sectional. CONTEXT: Gluteus medius (GM) muscle dysfunction is associated with overuse injury. The GM is functionally composed of 3 separate subdivisions: anterior, middle, and posterior. Clinical assessment of the GM subdivisions is relevant to detect strength and activation...

  8. Stochastic models for strength of wind turbine blades using tests

    DEFF Research Database (Denmark)

    Toft, H.S.; Sørensen, John Dalsgaard

    2008-01-01

    The structural cost of wind turbine blades is dependent on the values of the partial safety factors which reflect the uncertainties in the design values, including statistical uncertainty from a limited number of tests. This paper presents a probabilistic model for ultimate and fatigue strength...... of wind turbine blades especially considering the influence of prior knowledge and test results and how partial safety factors can be updated when additional full-scale tests are performed. This updating is performed by adopting a probabilistic design basis based on Bayesian statistical methods....

  9. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics

    Science.gov (United States)

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-01-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen’s size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics. PMID:26816646

  10. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics.

    Science.gov (United States)

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-12-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen's size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics.

  11. Microclimate boxes for panel paintings

    DEFF Research Database (Denmark)

    Wadum, Jørgen

    1998-01-01

    The use of microclimate boxes to protect vulnerable panel paintings is, therefore, not a new phenomenon of the past two or three decades. Rather, it has been a concern for conservators and curators to protect these objects of art at home and in transit since the end of the nineteenth century....... The increased number of travelling exhibitions in recent years has heightened the need to protect paintings during circulation (Thomson 1961; Mecklenburg 1991). The use and design of microclimate boxes have been evolving since 1892. These boxes may be divided into three broad groups: those using an active...... buffer material to stabilize the internal RH, a more recent box containing no added buffer material, and, in recent times, boxes with an altered gas content. Another concern is the appearance (aesthetics) of the box....

  12. Boxing-related head injuries.

    Science.gov (United States)

    Jayarao, Mayur; Chin, Lawrence S; Cantu, Robert C

    2010-10-01

    Fatalities in boxing are most often due to traumatic brain injury that occurs in the ring. In the past 30 years, significant improvements in ringside and medical equipment, safety, and regulations have resulted in a dramatic reduction in the fatality rate. Nonetheless, the rate of boxing-related head injuries, particularly concussions, remains unknown, due in large part to its variability in clinical presentation. Furthermore, the significance of repeat concussions sustained when boxing is just now being understood. In this article, we identify the clinical manifestations, pathophysiology, and management of boxing-related head injuries, and discuss preventive strategies to reduce head injuries sustained by boxers.

  13. Design and production of a novel sand materials strength testing machine for foundry applications

    DEFF Research Database (Denmark)

    Nwaogu, Ugochukwu Chibuzoh; Hansen, K. S.; Tiedje, Niels Skat

    2012-01-01

    testing machine was designed and built for both green sand and chemically-bonded sand materials. This machine measures and presents the loading response as a force-displacement profile from which the mechanical properties of the moulding materials can be deduced. The system was interfaced to a computer......In the foundry, existing strength testing machines are used to measure only the maximum fracture strength of mould and core materials. With traditionally used methods, the loading history to ascertain deformation of the material is not available. In this paper, a novel moulding material strength...... with a commercial PC based-control and data acquisition software. The testing conditions and operations are specified in the user interface and the data acquisition is made according to specifications. The force and displacements were calibrated to ensure consistency and reliability of the measurement data...

  14. Four-Point Bending Strength Testing of Pultruded Fiberglass Composite Wind Turbine Blade Sections

    International Nuclear Information System (INIS)

    Musial, W.; Bourne, B; Hughes, S; Zuteck, M. D.

    2001-01-01

    The ultimate strength of the PS Enterprises pultruded blade section was experimentally determined under four-point bending at the National Renewable Energy Laboratory. Thirteen 8-foot long full-scale blade segments were individually tested to determine their maximum moment carrying capability. Three airfoil-bending configurations were tested: high- and low-pressure skin buckling, and low pressure skin buckling with foam interior reinforcement. Maximum strain was recorded for each sample on the compressive and tensile surfaces of each test blade. Test data are compared to the results of three analytical buckling prediction methods. Based on deviations from the linear strain versus load curve, data indicate a post-buckling region. High-pressure side buckling occurred sooner than low-pressure side buckling. The buckling analyses were conservative for both configurations, but high-pressure side buckling in particular was substantially under-predicted. Both high- and low-pressure buckling configurations had very similar failure loads. These results suggests that a redundant load path may be providing strength to the section in the post-buckling region, making the onset of panel buckling a poor predictor of ultimate strength for the PS Enterprises pultrusion

  15. Compressive strength test for cemented waste forms: validation process

    International Nuclear Information System (INIS)

    Haucz, Maria Judite A.; Candido, Francisco Donizete; Seles, Sandro Rogerio

    2007-01-01

    In the Cementation Laboratory (LABCIM), of the Development Centre of the Nuclear Technology (CNEN/CDTN-MG), hazardous/radioactive wastes are incorporated in cement, to transform them into monolithic products, preventing or minimizing the contaminant release to the environment. The compressive strength test is important to evaluate the cemented product quality, in which it is determined the compression load necessary to rupture the cemented waste form. In LABCIM a specific procedure was developed to determine the compressive strength of cement waste forms based on the Brazilian Standard NBR 7215. The accreditation of this procedure is essential to assure reproductive and accurate results in the evaluation of these products. To achieve this goal the Laboratory personal implemented technical and administrative improvements in accordance with the NBR ISO/IEC 17025 standard 'General requirements for the competence of testing and calibration laboratories'. As the developed procedure was not a standard one the norm ISO/IEC 17025 requests its validation. There are some methodologies to do that. In this paper it is described the current status of the accreditation project, especially the validation process of the referred procedure and its results. (author)

  16. Invariant box-parameterization of neutrino oscillations

    International Nuclear Information System (INIS)

    Weiler, Thomas J.; Wagner, DJ

    1998-01-01

    The model-independent 'box' parameterization of neutrino oscillations is examined. The invariant boxes are the classical amplitudes of the individual oscillating terms. Being observables, the boxes are independent of the choice of parameterization of the mixing matrix. Emphasis is placed on the relations among the box parameters due to mixing-matrix unitarity, and on the reduction of the number of boxes to the minimum basis set. Using the box algebra, we show that CP-violation may be inferred from measurements of neutrino flavor mixing even when the oscillatory factors have averaged. General analyses of neutrino oscillations among n≥3 flavors can readily determine the boxes, which can then be manipulated to yield magnitudes of mixing matrix elements

  17. Safety evaluation for packaging CPC metal boxes

    International Nuclear Information System (INIS)

    Romano, T.

    1995-01-01

    This Safety Evaluation for Packaging (SEP) provides authorization for the use of Container Products Corporation (CPC) metal boxes, as described in this document, for the interarea shipment of radioactive contaminated equipment and debris for storage in the Central Waste Complex (CWC) or T Plant located in the 200 West Area. Authorization is granted until November 30, 1995. The CPC boxes included in this SEP were originally procured as US Department of Transportation (DOT) Specification 7A Type A boxes. A review of the documentation provided by the manufacturer revealed the documentation did not adequately demonstrate compliance to the 4 ft drop test requirement of 49 CFR 173.465(c). Preparation of a SEP is necessary to document the equivalent safety of the onsite shipment in lieu of meeting DOT packaging requirements until adequate documentation is received. The equivalent safety of the shipment is based on the fact that the radioactive contents consist of contaminated equipment and debris which are not dispersible. Each piece is wrapped in two layers of no less than 4 mil plastic prior to being placed in the box which has an additional 10 mil liner. Pointed objects and sharp edges are padded to prevent puncture of the plastic liner and wrapping

  18. The relation between knee muscle strength and performance tests in orienteering athletes.

    Science.gov (United States)

    Çinar-Medeni, Özge; Colakoglu, Fatma F; Yüce, Koray; Ipekoğlu, Gökhan; Baltaci, Gul

    2016-11-01

    The aim of this study was to analyze the effect of knee muscle strength on performance tests in orienteers. Thirty-seven orienteers were voluntarily included in this study. Isokinetic knee flexor and extensor muscles' strength was assessed at 120°/s velocity for both "dominant leg" (DL) and "non-dominant leg" (NDL). "Single-legged hop test" (SLHT), "flamingo balance test" (FBT), "star excursion balance test" (SEBT), vertical jump-and-reach test (for anaerobic power), T-drill test and 20-meter shuttle run test (for aerobic power) were carried out. Correlation and regression analyses were performed on the data. VO2max levels showed moderate correlations with DL's "flexor peak torque" (FPT) and NDL's "extensor peak torque" (EPT) and FPT values respectively (r=0.49, r=0.38, r=0.58). FPT of NDL was a predictor of VO2max level (R2=0.33). Anaerobic power has a relationship with EPT of NDL (r=0.43) and T-drill test with EPT and FPT values of both DL and NDL respectively (r=-0.35, r=-0.63, r=-0.53, r=-0.58). EPT of NDL was a predictor for anaerobic power (R2=0.19) and FPT of DL for agility (R2=0.40). Nonparametric linear regression results showed that EPT is a predictor in DL (median slope=-0.71, P=0.01), and FPT in NDL (median slope=-0.90, P=0.006) for FBT. FPT was a predictor of SEBT scores for both legs (0.13strength are of importance to improve orienteering performance.

  19. First-aid boxes - Reminder

    CERN Multimedia

    GS Department

    2010-01-01

    With a view to ensuring optimum use of the first-aid boxes on the CERN site, we should like to remind you of various changes introduced in March 2009: The TSO of the buildings concerned is responsible for the first-aid boxes, including checking their contents.   First-aid boxes may be restocked ONLY at the CERN stores (SCEM No. 54.99.80). This is no longer possible at the Infirmary. The associated cost is charged to the Departments.   First-aid boxes should be used only for mild injuries. All other cases should be referred to the Medical Service Infirmary (Bldg. 57 – ground-floor, tel. 73802) between 8.00 a.m. and 5.30 p.m. or to the Fire and Rescue Service (tel. 74444). N.B.: This information does not apply to the red emergency first-aid boxes in the underground areas or to the emergency kits for use in the event of being splashed with hydrofluoric acid.

  20. An investigation of drag reduction on box-shaped ground vehicles

    Science.gov (United States)

    Muirhead, V. U.

    1976-01-01

    A wind tunnel investigation was conducted to determine the reduction in drag which could be obtained by making various configuration changes to a box-shaped ground vehicle. Tests were conducted at yaw (relative wind) angles of 0, 5, 10, 20, and 30 degrees and Reynolds numbers of 300,000 to 850,000. The power required to overcome the aerodynamic drag was reduced by a maximum of 73% for a head wind for the best configuration relative to the smooth bottom box-shape, or 75% relative to the rough bottom box-shape. The reduction for a 20 MPH wind at 30 deg to the vehicle path was, respectively, 77% and 79%.

  1. Fresh Properties and Flexural Strength of Self-Compacting Concrete Integrating Coal Bottom Ash

    Directory of Open Access Journals (Sweden)

    Jamaluddin Norwati

    2016-01-01

    Full Text Available This paper presents the effect of using coal bottom ash as a partial replacement of fine aggregates in self-compacting concrete (SCC on its fresh properties and flexural strength. A comparison between SCC with various replacements of fine aggregates with coal bottom ash showed that SCC obtained flexural strength decrease on increase of water cement ratio from 0.35 to 0.45. The natural sand was replaced with coal bottom ash up to 30% volumetrically. The fresh properties were investigated by slump flow, T500 spread time, L-box test and sieve segregation resistance in order to evaluate its self-compatibility by compared to control samples embed with natural sand. The results revealed that the flowability and passing ability of SCC mixtures are decreased with higher content of coal bottom ash replacement. The results also showed that the flexural strength is affected by the presence of coal bottom ash in the concrete. In addition, the water cement ratios are influence significantly with higher binder content in concrete.

  2. The use of a volcanic material as filler in self-compacting concrete production for lower strength applications

    Directory of Open Access Journals (Sweden)

    D. Burgos

    2017-01-01

    Full Text Available This study evaluates the use of large amounts of fine powders (fillers derived from a Colombian volcanic material into the production of self-compacting concrete (SCC for lower strength applications. The effects on SCC properties were studied with the incorporation of up to 50% of volcanic material of Tolima (MVT as a partial substitute of the total weight of Portland cement. The workability was determined through slump flow, V-funnel, and L-box test. The compressive strength results were analyzed statistically by MINITAB. These demonstrated that 30% (by total weight of cementitious material was the maximum allowable percentage of MVT to be used in the production of SCCs. Based on this, mechanical and permeability properties of SCC MVT 30% were evaluated at 28, 90 y 360 curing days. SCC MVT 30% exhibited compressive strength of 21 and 27 MPa after 28 and 360 days of curing, respectively.

  3. The use of a volcanic material as filler in self-compacting concrete production for lower strength applications

    International Nuclear Information System (INIS)

    Burgos, D.; Guzmán, A.; Hossain, K.M.A.; Delvasto, S.

    2017-01-01

    This study evaluates the use of large amounts of fine powders (fillers) derived from a Colombian volcanic material into the production of self-compacting concrete (SCC) for lower strength applications. The effects on SCC properties were studied with the incorporation of up to 50% of volcanic material of Tolima (MVT) as a partial substitute of the total weight of Portland cement. The workability was determined through slump flow, V-funnel, and L-box test. The compressive strength results were analyzed statistically by MINITAB. These demonstrated that 30% (by total weight of cementitious material) was the maximum allowable percentage of MVT to be used in the production of SCCs. Based on this, mechanical and permeability properties of SCC MVT 30% were evaluated at 28, 90 y 360 curing days. SCC MVT 30% exhibited compressive strength of 21 and 27 MPa after 28 and 360 days of curing, respectively. [es

  4. Repackaging SRS Black Box TRU Waste

    International Nuclear Information System (INIS)

    Swale, D. J.; Stone, K.A.; Milner, T. N.

    2006-01-01

    Historically, large items of TRU Waste, which were too large to be packaged in drums for disposal have been packaged in various sizes of custom made plywood boxes at the Savannah River Site (SRS), for many years. These boxes were subsequently packaged into large steel ''Black Boxes'' for storage at SRS, pending availability of Characterization and Certification capability, to facilitate disposal of larger items of TRU Waste. There are approximately 107 Black Boxes in inventory at SRS, each measuring some 18' x 12' x 7', and weighing up to 45,000 lbs. These Black Boxes have been stored since the early 1980s. The project to repackage this waste into Standard Large Boxes (SLBs), Standard Waste Boxes (SWB) and Ten Drum Overpacks (TDOP), for subsequent characterization and WIPP disposal, commenced in FY04. To date, 10 Black Boxes have been repackaged, resulting in 40 SLB-2's, and 37 B25 overpack boxes, these B25's will be overpacked in SLB-2's prior to shipping to WIPP. This paper will describe experience to date from this project

  5. PCB-Based Break-Out Box

    Science.gov (United States)

    Lee, Jason H.

    2011-01-01

    Break-out boxes (BOBs) are necessary for all electrical integration/cable checkouts and troubleshooting. Because the price of a BOB is high, and no work can be done without one, often the procedure stops, simply waiting for a BOB. A less expensive BOB would take less time in the integration, testing, and troubleshooting process. The PCB-based BOB works and looks the same as a standard JPL BOB, called Gold Boxes. The only differences between the old BOB and the new PCB-based BOB is that the new one has 80 percent of its circuitry in a printed circuit board. This process reduces the time for fabrication, thus making the BOBs less expensive. Moreover, because of its unique design, the new BOBs can be easily assembled and fixed. About 80 percent of the new PCB-based BOB is in a $22 (at the time of this reporting) custom-designed, yet commercially available PCB. This device has been used successfully to verify that BOB cables were properly made. Also, upon completion, the BOB was beeped out via a multimeter to ensure that all sockets on the connectors were properly connected to the respective banana jack. When compared to the Gold Box BOBs, the new BOB has many advantages. It is much more cost efficient, it delivers equal usability at substantially lower cost of the BOB, and the Gold Box is much heavier when compared to the new BOB. The new BOB is also a bit longer and much more versatile in that connectors are easily changeable and if a banana jack is broken, it can be replaced instead of throwing away an entire BOB.

  6. Effectiveness of box trainers in laparoscopic training

    Directory of Open Access Journals (Sweden)

    Dhariwal Anender

    2007-01-01

    Full Text Available Rationale and Objectives: Various devices are used to aid in the education of laparoscopic skills ranging from simple box trainers to sophisticated virtual reality trainers. Virtual reality system is an advanced and effective training method, however it is yet to be adopted in India due to its cost and the advanced technology required for it. Therefore, box trainers are being used to train laparoscopic skills. Hence this study was undertaken to assess the overall effectiveness of the box-training course. Study Procedure: The study was conducted during six-day laparoscopic skills training workshops held during 2006. Twenty five surgeons; age range of 26 to 45 years, of either sex, who had not performed laparoscopic surgery before; attending the workshop were evaluated. Each participant was given a list of tasks to perform before beginning the box-training course on day one and was evaluated quantitatively by rating the successful completion of each test. Evaluation began when the subject placed the first tool into the cannula and ended with task completion. Two evaluation methods used to score the subject, including a global rating scale and a task-specific checklist. After the subject completed all sessions of the workshop, they were asked to perform the same tasks and were evaluated in the same manner. For each task completed by the subjects, the difference in the scores between the second and first runs were calculated and interpreted as an improvement as a percentage of the initial score. Statistical Analysis: Wilcoxon matched-paired signed-ranks test was applied to find out the statistical significance of the results obtained. Results: The mean percentage improvement in scores for both the tasks, using global rating scale, was 44.5% + 6.930 (Mean + SD. For task 1, using the global rating scale mean percentage improvement was 49.4% + 7.948 (Mean + SD. For task 2, mean percentage improvement using global rating scale was 39.6% + 10.4 (Mean

  7. Invariant box parameterization of neutrino oscillations

    International Nuclear Information System (INIS)

    Weiler, T.J.; Wagner, D.

    1998-01-01

    The model-independent 'box' parameterization of neutrino oscillations is examined. The invariant boxes are the classical amplitudes of the individual oscillating terms. Being observables, the boxes are independent of the choice of parameterization of the mixing matrix. Emphasis is placed on the relations among the box parameters due to mixing matrix unitarity, and on the reduction of the number of boxes to the minimum basis set. Using the box algebra, we show that CP-violation may be inferred from measurements of neutrino flavor mixing even when the oscillatory factors have averaged. General analyses of neutrino oscillations among n≥3 flavors can readily determine the boxes, which can then be manipulated to yield magnitudes of mixing matrix elements. copyright 1998 American Institute of Physics

  8. Box-particle intensity filter

    OpenAIRE

    Schikora, Marek; Gning, Amadou; Mihaylova, Lyudmila; Cremers, Daniel; Koch, Wofgang; Streit, Roy

    2012-01-01

    This paper develops a novel approach for multi-target tracking, called box-particle intensity filter (box-iFilter). The approach is able to cope with unknown clutter, false alarms and estimates the unknown number of targets. Furthermore, it is capable of dealing with three sources of uncertainty: stochastic, set-theoretic and data association uncertainty. The box-iFilter reduces the number of particles significantly, which improves the runtime considerably. The low particle number enables thi...

  9. The relationship between compressive strength and flexural strength of pavement geopolymer grouting material

    Science.gov (United States)

    Zhang, L.; Han, X. X.; Ge, J.; Wang, C. H.

    2018-01-01

    To determine the relationship between compressive strength and flexural strength of pavement geopolymer grouting material, 20 groups of geopolymer grouting materials were prepared, the compressive strength and flexural strength were determined by mechanical properties test. On the basis of excluding the abnormal values through boxplot, the results show that, the compressive strength test results were normal, but there were two mild outliers in 7days flexural strength test. The compressive strength and flexural strength were linearly fitted by SPSS, six regression models were obtained by linear fitting of compressive strength and flexural strength. The linear relationship between compressive strength and flexural strength can be better expressed by the cubic curve model, and the correlation coefficient was 0.842.

  10. Laboratory test for ice adhesion strength using commercial instrumentation.

    Science.gov (United States)

    Wang, Chenyu; Zhang, Wei; Siva, Adarsh; Tiea, Daniel; Wynne, Kenneth J

    2014-01-21

    A laboratory test method for evaluating ice adhesion has been developed employing a commercially available instrument normally used for dynamic mechanical analysis (TA RSA-III). This is the first laboratory ice adhesion test that does not require a custom-built apparatus. The upper grip range of ∼10 mm is an enabling feature that is essential for the test. The method involves removal of an ice cylinder from a polymer coating with a probe and the determination of peak removal force (Ps). To validate the test method, the strength of ice adhesion was determined for a prototypical glassy polymer, poly(methyl methacrylate). The distance of the probe from the PMMA surface has been identified as a critical variable for Ps. The new test provides a readily available platform for investigating fundamental surface characteristics affecting ice adhesion. In addition to the ice release test, PMMA coatings were characterized using DSC, DCA, and TM-AFM.

  11. Comparative evaluation of tensile bond strength and microleakage of conventional glass ionomer cement, resin modified glass ionomer cement and compomer: An in vitro study.

    Science.gov (United States)

    Rekha, C Vishnu; Varma, Balagopal; Jayanthi

    2012-07-01

    The purpose of this study was to evaluate and compare the tensile bond strength and microleakage of Fuji IX GP, Fuji II LC, and compoglass and to compare bond strength with degree of microleakage exhibited by the same materials. Occlusal surfaces of 96 noncarious primary teeth were ground perpendicular to long axis of the tooth. Preparations were distributed into three groups consisting of Fuji IX GP, Fuji II LC and Compoglass. Specimens were tested for tensile bond strength by mounting them on Instron Universal Testing Machine. Ninety-six primary molars were treated with Fuji IX GP, Fuji II LC, and compoglass on box-only prepared proximal surface. Samples were thermocycled, stained with dye, sectioned, and scored for microleakage under stereomicroscope. ANOVA and Bonferrani correction test were done for comparisons. Pearson Chi-square test and regression analysis were done to assess the association between the parameters. Compoglass showed highest tensile strength and Fuji II LC showed least microleakage. There was a significant difference between the three groups in tensile strength and microleakage levels. The correlation between tensile strength and microleakage level in each group showed that there was a significant negative correlation only in Group 3. Fuji II LC and compoglass can be advocated in primary teeth because of their superior physical properties when compared with Fuji IX GP.

  12. Comparative evaluation of tensile bond strength and microleakage of conventional glass ionomer cement, resin modified glass ionomer cement and compomer: An in vitro study

    Directory of Open Access Journals (Sweden)

    C Vishnu Rekha

    2012-01-01

    Full Text Available Aim: The purpose of this study was to evaluate and compare the tensile bond strength and microleakage of Fuji IX GP, Fuji II LC, and compoglass and to compare bond strength with degree of microleakage exhibited by the same materials. Materials and Methods: Occlusal surfaces of 96 noncarious primary teeth were ground perpendicular to long axis of the tooth. Preparations were distributed into three groups consisting of Fuji IX GP, Fuji II LC and Compoglass. Specimens were tested for tensile bond strength by mounting them on Instron Universal Testing Machine. Ninety-six primary molars were treated with Fuji IX GP, Fuji II LC, and compoglass on box-only prepared proximal surface. Samples were thermocycled, stained with dye, sectioned, and scored for microleakage under stereomicroscope. ANOVA and Bonferrani correction test were done for comparisons. Pearson Chi-square test and regression analysis were done to assess the association between the parameters. Results: Compoglass showed highest tensile strength and Fuji II LC showed least microleakage. There was a significant difference between the three groups in tensile strength and microleakage levels. The correlation between tensile strength and microleakage level in each group showed that there was a significant negative correlation only in Group 3. Conclusion: Fuji II LC and compoglass can be advocated in primary teeth because of their superior physical properties when compared with Fuji IX GP.

  13. Molecular cloning and characterization of an F-box family gene CarF-box1 from chickpea (Cicer arietinum L.).

    Science.gov (United States)

    Jia, Yuying; Gu, Hanyan; Wang, Xiansheng; Chen, Quanjia; Shi, Shubing; Zhang, Jusong; Ma, Lin; Zhang, Hua; Ma, Hao

    2012-03-01

    F-box protein family has been found to play important roles in plant development and abiotic stress responses via the ubiquitin pathway. In this study, an F-box gene CarF-box1 (for Cicer arietinum F-box gene 1, Genbank accession no. GU247510) was isolated based on a cDNA library constructed with chickpea seedling leaves treated by polyethylene glycol. CarF-box1 encoded a putative protein with 345 amino acids and contained no intron within genomic DNA sequence. CarF-box1 is a KFB-type F-box protein, having a conserved F-box domain in the N-terminus and a Kelch repeat domain in the C-terminus. CarF-box1 was localized in the nucleus. CarF-box1 exhibited organ-specific expression and showed different expression patterns during seed development and germination processes, especially strongly expressed in the blooming flowers. In the leaves, CarF-box1 could be significantly induced by drought stress and slightly induced by IAA treatment, while in the roots, CarF-box1 could be strongly induced by drought, salinity and methyl jasmonate stresses. Our results suggest that CarF-box1 encodes an F-box protein and may be involved in various plant developmental processes and abiotic stress responses.

  14. Strength Prediction and Failure Modes of Concrete Specimens Subjected to the Split Test

    DEFF Research Database (Denmark)

    Hoang, Linh Cao; Andersen, M.E.; Hansen, N.T.

    2014-01-01

    This paper deals with modelling and test of concrete specimens subjected to the Brazilian split test. Based on the fictitious crack concept, a simple model for the crack propagation process in the splitting plane is developed. From the model, it is possible to determine the distribution of residual...... tensile strength as crack propagation take place. The residual tensile strength is thereafter used in a rigid plastic analysis of the splitting failure. Based on this combined approach, the ultimate load may either be governed by crack propagation or by a plastic failure, which then terminates the crack...

  15. A flexible system to capture sample vials in a storage box - the box vial scanner.

    Science.gov (United States)

    Nowakowski, Steven E; Kressin, Kenneth R; Deick, Steven D

    2009-01-01

    Tracking sample vials in a research environment is a critical task and doing so efficiently can have a large impact on productivity, especially in high volume laboratories. There are several challenges to automating the capture process, including the variety of containers used to store samples. We developed a fast and robust system to capture the location of sample vials being placed in storage that allows the laboratories the flexibility to use sample containers of varying dimensions. With a single scan, this device captures the box identifier, the vial identifier and the location of each vial within a freezer storage box. The sample vials are tracked through a barcode label affixed to the cap while the boxes are tracked by a barcode label on the side of the box. Scanning units are placed at the point of use and forward data to a sever application for processing the scanned data. Scanning units consist of an industrial barcode reader mounted in a fixture positioning the box for scanning and providing lighting during the scan. The server application transforms the scan data into a list of storage locations holding vial identifiers. The list is then transferred to the laboratory database. The box vial scanner captures the IDs and location information for an entire box of sample vials into the laboratory database in a single scan. The system accommodates a wide variety of vials sizes by inserting risers under the sample box and a variety of storage box layouts are supported via the processing algorithm on the server.

  16. Dimension measuring method for channel box

    International Nuclear Information System (INIS)

    Jo, Hiroto.

    1995-01-01

    The device of the present invention concerns detection of a channel box for spent fuel assemblies of a BWR type reactor, which measures a cross sectional shape and dimension of the channel box to check deformation amount such as expansion. That is, a customary fuel exchanger and a dimension measuring device are used. The lower end of the channel box is measured by a distance sensor of the dimension measuring device when it is aligned with a position of the distance sensor. The channel box is lowered at the same time while detecting axial position data of the fuel exchanger. The position of the channel box in an axial direction is detected based on axial position data of the fuel exchanger. The lower end of the channel box can accurately be recognized by the detection of both of them. Subsequent deformation measurement for the channel box at accurate axial positions is enabled. In addition, since the axial position data of the fuel exchanger per se are detected, an axial profile of the channel box can be measured even if a lifting speed of the channel box is varied on every region. (I.S.)

  17. Experimental study of multipurpose solar hot box at Freiburg, Germany

    Energy Technology Data Exchange (ETDEWEB)

    Nandwani, S.S. [Iowa State University, Ames (United States). International Inst. of Theoretical and Applied Physics; Steinhart, J.; Henning, H.M.; Rommel, M.; Wittwer, V. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany)

    1997-12-31

    With the aim to test an compare some properties of materials and common geometries that are used for designing solar cookers, water heaters, etc. we have made a solar hot box with two similar compartments. In the present study this hot box has been used for, (a) comparing the behavior of a metallic slab filled with a phase change material for short term heat storage, with a conventional absorbing sheet, (b) the use of a selectively coated, as compared to a normal black painted, cooking pot, and (c) for finding the overall heat loss coefficient and thermal capacity of the box. Experiments with the solar hot box will yield valuable information on solar systems that are to be constructed. Besides its use for research this multi-purpose device has been used both to pasteurize up to 14-16 l of water and for cooking. (author)

  18. Effect of testing methods on the bond strength of resin to zirconia-alumina ceramic : microtensile versus shear test

    NARCIS (Netherlands)

    Valandro, Luiz F.; Ozcan, Mutlu; Amaral, Regina; Vanderlei, Aleska; Bottino, Marco A.

    2008-01-01

    This study tested the bond strength of a resin cement to a glass-infiltrated zirconia-alumina ceramic after three conditioning methods and using two test methods (shear-SBS versus microtensile-MTBS). Ceramic blocks for MTBS and ceramic disks for SBS were fabricated. Three surface conditioning (SC)

  19. Pushing through evolution? Incidence and fight records of left-oriented fighters in professional boxing history.

    Science.gov (United States)

    Loffing, Florian; Hagemann, Norbert

    2015-05-01

    The fighting hypothesis proposes that left-oriented athletes enjoy a negative frequency-dependent advantage in combat sports such as boxing. Supporting evidence, however, is restricted to cross-sectional frequency data from small samples. Here, we examined the incidence and fight records of 2,403 left- and right-oriented fighters who were listed in the annual ratings of professional boxing from 1924 to 2012. Unexpectedly, left-oriented boxers were overrepresented in no more than 7 of the 89 years considered, their percentages varied up to 30% and increased over the entire period, and frequencies varied substantially between weight divisions. In support of the fighting hypothesis, lose-win ratios indicated larger fighting strength in left- compared to right-oriented boxers, which, however, was not reflected in different proportions of wins and losses by knockout. Our findings are partly consistent with an assumed left-oriented fighters' advantage in combat sports. Such advantage could be explained by negative frequency-dependent selection mechanisms; however, our study also revealed potential limits of the fighting hypothesis such that alternative explanations cannot be fully excluded. We propose that interference by factors not related to performance could also limit the suitability of data from elite sporting competition for testing evolutionary models of human handedness.

  20. Small-Scale Water Ingression and Crust Strength Tests (SSWICS) SSWICS-6 test data report: thermal hydraulic results, Rev. 0

    International Nuclear Information System (INIS)

    Lomperski, S.; Farmer, M.T.; Kilsdonk, D.; Aeschlimann, B.

    2011-01-01

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure? (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are being conducted to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium (∼ φ 30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. The issue of crust strength is being addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus measures the fracture strength of the crust while it is either at room temperature or above, the latter state being achieved with a heating element placed below the crust. The two apparatuses used to measure the melt quench rate and crust strength are jointly referred to as SSWICS (Small-Scale Water Ingression and Crust Strength). This report describes results of the sixth water ingression test, designated SSWICS-6. This test investigated

  1. Hip abduction-adduction strength and one-leg hop tests: test-retest reliability and relationship to function in elite ice hockey players.

    Science.gov (United States)

    Kea, J; Kramer, J; Forwell, L; Birmingham, T

    2001-08-01

    Single group, test-retest. To determine: (1) hip abduction and adduction torques during concentric and eccentric muscle actions, (2) medial and lateral one-leg hop distances, (3) the test-retest reliability of these measurements, and (4) the relationship between isokinetic measures of hip muscle strength and hop distances in elite ice hockey players. The skating motion used in ice hockey requires strong contractions of the hip and knee musculature. However, baseline scores for hip strength and hop distances, their test-retest reliability, and measures of the extent to which these tests are related for this population are not available. The dominant leg of 27 men (mean age 20 +/- 3 yrs) was tested on 2 occasions. Hip abduction and adduction movements were completed at 60 degrees.s(-1) angular velocity, with the subject lying on the non-test side and the test leg moving vertically in the subject's coronal plane. One-leg hops requiring jumping from and landing on the same leg without losing balance were completed in the medial and lateral directions. Hip adduction torques were significantly greater than abduction torques during both concentric and eccentric muscle actions, while no significant difference was observed between medial and lateral hop distances. Although hop test scores produced excellent ICCs (> 0.75) when determined using scores on 1 occasion, torques needed to be averaged over 2 test occasions to reach this level. Correlations between the strength and hop tests ranged from slight to low (r = -0.26 to 0.27) and were characterized by wide 95% confidence intervals (-0.54 to 0.61). Isokinetic tests of hip abduction and adduction did not provide a strong indication of performance during sideways hop tests. Although isokinetic tests can provide a measure of muscular strength under specific test conditions, they should not be relied upon as a primary indicator of functional abilities or readiness to return to activity.

  2. Reliability of a device for the knee and ankle isometric and isokinetic strength testing in older adults.

    Science.gov (United States)

    Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea

    2017-01-01

    Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (pisometric strength provided reliable test-retest measures in healthy older adults. Ib.

  3. Performance Aspects and Physiological Responses in Male Amateur Boxing Competitions: A Brief Review.

    Science.gov (United States)

    Slimani, Maamer; Chaabène, Helmi; Davis, Philip; Franchini, Emerson; Cheour, Foued; Chamari, Karim

    2017-04-01

    Slimani, M, Chaabène, H, Davis, P, Franchini, E, Cheour, F, and Chamari, K. Performance aspects and physiological responses in male amateur boxing competitions: a brief review. J Strength Cond Res 31(4): 1132-1141, 2017-Boxing is one of the most popular striking combat sports in the world. The aim of this review was to present data concerning performance analysis (time-motion and technical-tactical analysis) and physiological responses (i.e., blood lactate concentration [BLC], heart rate, and oxygen consumption) during novice and elite male simulated and official amateur boxing competitions in any age category. The present review shows that boxing competition is a high-intensity intermittent striking combat sport. Typically, the activity-to-rest ratio was higher in elite (18:1) than in novice (9:1) boxers and significant differences were observed between rounds (first round = 16:1, second round = 8:1, and third round = 6:1) in novice boxers. Thus, total stop-time and total stop-frequency increased over subsequent rounds in novice boxers. The technical-tactical aspects in elite and novice boxing bouts were different between rounds and dependent on the match outcome (i.e., winners vs. losers). Particularly, the current review highlights that triple-punch combinations, total combinations, block- and counter-punch combinations, total punches to the head, technical performance effectiveness, and defensive- and offensive-skills effectiveness may have contributed to win in novice and elite boxing competitions. Higher frequencies of technical movements were also observed in elite compared with novice boxers. From a physiological point of view, BLC increased significantly from postround 1 compared with postround 3 in novice boxing match. BLC was also higher in official than in simulated elite boxing matches in senior compared with junior boxers and in medium heavy-weight category compared with light- and medium-weight categories in junior boxing competition. A higher

  4. On the impact bending test technique for high-strength pipe steels

    Science.gov (United States)

    Arsenkin, A. M.; Odesskii, P. D.; Shabalov, I. P.; Likhachev, M. V.

    2015-10-01

    It is shown that the impact toughness (KCV-40 = 250 J/cm2) accepted for pipe steels of strength class K65 (σy ≥ 550 MPa) intended for large-diameter gas line pipes is ineffective to classify steels in fracture strength. The results obtained upon testing of specimens with a fatigue crack and additional sharp lateral grooves seem to be more effective. In energy consumption, a macrorelief with splits is found to be intermediate between ductile fracture and crystalline brittle fracture. A split formation mechanism is considered and a scheme is proposed for split formation.

  5. A PC parallel port button box provides millisecond response time accuracy under Linux.

    Science.gov (United States)

    Stewart, Neil

    2006-02-01

    For psychologists, it is sometimes necessary to measure people's reaction times to the nearest millisecond. This article describes how to use the PC parallel port to receive signals from a button box to achieve millisecond response time accuracy. The workings of the parallel port, the corresponding port addresses, and a simple Linux program for controlling the port are described. A test of the speed and reliability of button box signal detection is reported. If the reader is moderately familiar with Linux, this article should provide sufficient instruction for him or her to build and test his or her own parallel port button box. This article also describes how the parallel port could be used to control an external apparatus.

  6. On the channel box for the fuel bundle of BWR

    International Nuclear Information System (INIS)

    Yokoyama, Hiroomi; Yamamoto, Takeo

    1976-01-01

    Channel boxes play the important roles of making coolant flow uniform and protecting fuel rods as the component of fuel assemblies for BWRs. About ten years ago, the domestic production of channel boxes was first investigated, and now, the original technology has been developed, and the channel boxes sufficiently satisfying the required quality can be produced. The actual experience by being charged in reactors has also been accumulated. At present, the supply capacity is almost sufficient to meet the domestic demand, and the future increase of demand can be dealt with promptly. The channel boxes are made of Zircaloy-4 plates which are favorable in view of neutron absorption, and are the boxes with 138 mm hollow square section, 2 mm thickness, and 4240 mm length. Two channels were welded together and made into a box. In order to eliminate the residual stress caused during the manufacture, high temperature heating with an electric furnace was adopted. The measurement of dimensions and the inspection of appearance of the channel boxes after irradiation proved that they were rather superior to imported ones. The production processes, the system for the quality guarantee, and the quality control in the Kobe Steel Ltd. are explained. The test and inspection are carried out at the time of accepting outside products, before starting the production, after the completion of longitudinal welding and after the completion of production. (Kako, I.)

  7. Validation and Reliability of a Novel Test of Upper Body Isometric Strength.

    Science.gov (United States)

    Bellar, David; Marcus, Lena; Judge, Lawrence W

    2015-09-29

    The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a "push-up" style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (pIsometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment.

  8. A study on the safety of TBP(150A) with forming analysis and strength test

    International Nuclear Information System (INIS)

    Lee, Sung Ho; Kim, Hei Song

    2008-01-01

    For this study, the forming analyses and body strength tests of TBP were performed on the main pipe size 150A(KS D3507, KS D 3576 10S). The branched pipe sizes utilized were 25A, 32A, 40A, 50A, 65A, 80A, 100A and 125A. A general FEM program, ABAQUS, was used as the forming analyses method of TBP. Using the results, the strength of TBP was then tested in order to determine the safety of TBP when the working pressure was applied. The results indicate that TBP may be safely used in water-based fire protection pipe systems in terms of the strength

  9. Replacement of the glove box panel in nuclear fuel reprocessing facility

    International Nuclear Information System (INIS)

    Yamamoto, Masahiko; Shirouzu, Hidetomo; Mori, Eito; Surugaya, Naoki

    2016-05-01

    The panels for visual confirmation of glove box installed at Operation Testing Laboratory in Tokai Reprocessing Plant have been deteriorated and transparencies have been decreased due to the long-term use. Therefore, the glove box panels have been replaced from the view point of preventive maintenance. In the new regulation formulated since the accident at Tokyo Electric Power Company's Fukushima Daiichi Nuclear Power Station, it is demanded that the glove box consists of incombustible or noncombustible materials. In this replacement, the new panels have been manufactured with the polycarbonate which satisfied the UL94 V-0 incombustible class. The glove box has been in service for 40 years and its inside is contaminated with radioactive materials. Thus, the contaminations have been investigated and decontaminated before the replacement work. Then, operator's exposure and radiation protection equipment have been estimated. Also, it is necessary to replace the panels with maintaining the glove box's enclosure function. The replacement has been conducted in closed space covering the opening parts with vinyl sheets. The enclosure function has been verified by the inspection of the new panels and glove box. (author)

  10. BIOMECHANICS OF HEAD INJURY IN OLYMPIC TAEKWONDO AND BOXING

    Science.gov (United States)

    Fife, G.P.; Pieter, W.

    2013-01-01

    Objective The purpose was to examine differences between taekwondo kicks and boxing punches in resultant linear head acceleration (RLA), head injury criterion (HIC15), peak head velocity, and peak foot and fist velocities. Data from two existing publications on boxing punches and taekwondo kicks were compared. Methods For taekwondo head impacts a Hybrid II Crash Dummy (Hybrid II) head was instrumented with a tri-axial accelerometer mounted inside the Hybrid II head. The Hybrid II was fixed to a height-adjustable frame and fitted with a protective taekwondo helmet. For boxing testing, a Hybrid III Crash Dummy head was instrumented with an array of tri-axial accelerometers mounted at the head centre of gravity. Results Differences in RLA between the roundhouse kick (130.11±51.67 g) and hook punch (71.23±32.19 g, d = 1.39) and in HIC15 (clench axe kick: 162.63±104.10; uppercut: 24.10±12.54, d = 2.29) were observed. Conclusions Taekwondo kicks demonstrated significantly larger magnitudes than boxing punches for both RLA and HIC. PMID:24744497

  11. The Mind as Black Box: A Simulation of Theory Building in Psychology.

    Science.gov (United States)

    Hildebrandt, Carolyn; Oliver, Jennifer

    2000-01-01

    Discusses an activity that uses the metaphor "the mind is a black box," in which students work in groups to discover what is inside a sealed, black, plastic box. States that the activity enables students to understand the need for theories in psychology and to comprehend how psychologists build, test, and refine those theories. (CMK)

  12. Accelerated Comparative Fatigue Strength Testing of Belt Adhesive Joints

    Science.gov (United States)

    Bajda, Miroslaw; Blazej, Ryszard; Jurdziak, Leszek

    2017-12-01

    Belt joints are the weakest link in the serial structure that creates an endless loop of spliced belt segments. This affects not only the lower strength of adhesive joints of textile belts in comparison to vulcanized splices, but also the replacement of traditional glues to more ecological but with other strength parameters. This is reflected in the lowered durability of adhesive joints, which in underground coal mines is nearly twice shorter than the operating time of belts. Vulcanized splices require high precision in performance, they need long time to achieve cross-linking of the friction mixture and, above all, they require specialized equipment (vulcanization press) which is not readily available and often takes much time to be delivered down, which means reduced mining output or even downtime. All this reduces the reliability and durability of adhesive joints. In addition, due to the consolidation on the Polish coal market, mines are joined into large economic units serviced by a smaller number of processing plants. The consequence is to extend the transport routes downstream and increase reliability requirements. The greater number of conveyors in the chain reduces reliability of supply and increases production losses. With high fixed costs of underground mines, the reduction in mining output is reflected in the increase in unit costs, and this at low coal prices on the market can mean substantial losses for mines. The paper describes the comparative study of fatigue strength of shortened samples of adhesive joints conducted to compare many different variants of joints (various adhesives and materials). Shortened samples were exposed to accelerated fatigue in the usually long-lasting dynamic studies, allowing more variants to be tested at the same time. High correlation between the results obtained for shortened (100 mm) and traditional full-length (3×250 mm) samples renders accelerated tests possible.

  13. Formulation and Optimization of Oral Mucoadhesive Patches of Myrtus Communis by Box Behnken Design.

    Science.gov (United States)

    Hashemi, Mahbubeh; Ramezani, Vahid; Seyedabadi, Mohammad; Ranjbar, Ali Mohamad; Jafari, Hossein; Honarvar, Mina; Fanaei, Hamed

    2017-09-01

    Purpose: Recurrent aphthous stomatitis (RAS) is the most common painful ulcerative disease of oral mucosa happening in ~20% of people. Aimed to develop Myrtus communis L. (Myrtle) containing oral patches, we applied box-behnken design to evaluate the effect of polymers such as Polyvinyl pyrrolidone (PVP), Gelatin, Methylcellulose (MC) and Pectin. Methods: The patches properties such as tensile strength, folding endurance, swelling index, thickness, mucoadhesive strength and the pattern of myrtle release were evaluated as dependent variables. Then, the model was adjusted according to the best fitted equation with box behnken design. Results: The results indicated that preparation of myrtle patch with hydrophilic polymers showed the disintegration time up to 24h and more. Using of polyvinyl pyrrolidone as a water soluble polymer and a pore-former polymer led to faster release of soluble materials from the patch to 29 (min -1 ). Also it decreases swelling index by increasing the patch disintegration. Gelatin and Pectin, with rigid matrix and water interaction properties, decreased the swelling ratio. Pectin increased the tensile strength, but gelatin produced an opposite effect. Thinner Myrtle patch (about 28µm) was obtained by formulation of methyl cellulose with equal ratio with polyvinyl pyrrolidone or gelatin. Conclusion: Altogether, the analysis showed that the optimal formulation was achieved with of 35.04 mg of Gelatin, 7.22 mg of Pectin, 7.20 mg of polyvinyl pyrrolidone, 50.52 mg of methyl cellulose and 20 mg of Myrtle extract.

  14. The minimum sit-to-stand height test: reliability, responsiveness and relationship to leg muscle strength.

    Science.gov (United States)

    Schurr, Karl; Sherrington, Catherine; Wallbank, Geraldine; Pamphlett, Patricia; Olivetti, Lynette

    2012-07-01

    To determine the reliability of the minimum sit-to-stand height test, its responsiveness and its relationship to leg muscle strength among rehabilitation unit inpatients and outpatients. Reliability study using two measurers and two test occasions. Secondary analysis of data from two clinical trials. Inpatient and outpatient rehabilitation services in three public hospitals. Eighteen hospital patients and five others participated in the reliability study. Seventy-two rehabilitation unit inpatients and 80 outpatients participated in the clinical trials. The minimum sit-to-stand height test was assessed using a standard procedure. For the reliability study, a second tester repeated the minimum sit-to-stand height test on the same day. In the inpatient clinical trial the measures were repeated two weeks later. In the outpatient trial the measures were repeated five weeks later. Knee extensor muscle strength was assessed in the clinical trials using a hand-held dynamometer. The reliability for the minimum sit-to-stand height test was excellent (intraclass correlation coefficient (ICC) 0.91, 95% confidence interval (CI) 0.81-0.96). The standard error of measurement was 34 mm. Responsiveness was moderate in the inpatient trial (effect size: 0.53) but small in the outpatient trial (effect size: 0.16). A small proportion (8-17%) of variability in minimum sit-to-stand height test was explained by knee extensor muscle strength. The minimum sit-to-stand height test has excellent reliability and moderate responsiveness in an inpatient rehabilitation setting. Responsiveness in an outpatient rehabilitation setting requires further investigation. Performance is influenced by factors other than knee extensor muscle strength.

  15. Detection test of wireless network signal strength and GPS positioning signal in underground pipeline

    Science.gov (United States)

    Li, Li; Zhang, Yunwei; Chen, Ling

    2018-03-01

    In order to solve the problem of selecting positioning technology for inspection robot in underground pipeline environment, the wireless network signal strength and GPS positioning signal testing are carried out in the actual underground pipeline environment. Firstly, the strength variation of the 3G wireless network signal and Wi-Fi wireless signal provided by China Telecom and China Unicom ground base stations are tested, and the attenuation law of these wireless signals along the pipeline is analyzed quantitatively and described. Then, the receiving data of the GPS satellite signal in the pipeline are tested, and the attenuation of GPS satellite signal under underground pipeline is analyzed. The testing results may be reference for other related research which need to consider positioning in pipeline.

  16. Heart Rate and Liking During "Kinect Boxing" Versus "Wii Boxing": The Potential for Enjoyable Vigorous Physical Activity Videogames.

    Science.gov (United States)

    Sanders, Gabriel J; Peacock, Corey A; Barkley, Jacob E; Gish, Brian; Brock, Scott; Volpenhein, Josh

    2015-08-01

    Nintendo(®) (Kyoto, Japan) "Wii™ Sports Boxing" ("Wii Boxing") and Xbox(®) (Microsoft, Redmond, WA) "Kinect(®) Sports Boxing" ("Kinect Boxing") are both boxing simulation videogames that are available for two different active videogame (AVG) systems. Although these AVGs are similar, the style of gameplay required is different (i.e., upper body only versus total body movements) and may alter physical activity intensity and one's preference for playing one game over the other. AVGs that elicit the greatest physiologic challenge and are preferred by users should be identified in an effort to enhance the efficacy of physical activity interventions and programs that include AVGs. The mean heart rate (HRmean) and peak heart rate (HRpeak) for 27 adults (22.7±4.2 years old) were recorded during four 10-minute conditions: seated rest, treadmill walking at 3 miles/hour, "Wii Boxing," and "Kinect Boxing." Upon completion of all four conditions, participants indicated which condition they preferred, and HRmean and HRpeak were calculated as a percentage of age-predicted maximum heart rate to classify physical activity intensity for the three activity conditions (treadmill, "Wii Boxing," and "Kinect Boxing"). "Kinect Boxing" significantly (P<0.001) increased percentage HRmean (64.1±1.6 percent of age-predicted maximum) and percentage HRpeak (76.5±1.9 percent) above all other conditions: Wii HRmean, 53.0±1.2 percent; Wii HRpeak, 61.8±1.5 percent; treadmill HRmean, 52.4±1.2 percent; treadmill HRpeak, 55.2±2.2 percent. Percentage HRpeak for "Kinect Boxing" was great enough to be considered a vigorous-intensity physical activity. There was no difference (P=0.55) in percentage HRmean between "Wii Boxing" and treadmill walking. Participants also preferred "Kinect Boxing" (P<0.001; n=26) to all other conditions ("Wii Boxing," n=1; treadmill n=0). "Kinect Boxing" was the most preferred and the only condition that was physiologically challenging enough to be classified as a

  17. A Box-Cox normal model for response times.

    Science.gov (United States)

    Klein Entink, R H; van der Linden, W J; Fox, J-P

    2009-11-01

    The log-transform has been a convenient choice in response time modelling on test items. However, motivated by a dataset of the Medical College Admission Test where the lognormal model violated the normality assumption, the possibilities of the broader class of Box-Cox transformations for response time modelling are investigated. After an introduction and an outline of a broader framework for analysing responses and response times simultaneously, the performance of a Box-Cox normal model for describing response times is investigated using simulation studies and a real data example. A transformation-invariant implementation of the deviance information criterium (DIC) is developed that allows for comparing model fit between models with different transformation parameters. Showing an enhanced description of the shape of the response time distributions, its application in an educational measurement context is discussed at length.

  18. A new approach to the Box-Cox transformation

    Directory of Open Access Journals (Sweden)

    Jorge Iván eVélez

    2015-10-01

    Full Text Available We propose a new methodology to estimate λ, the parameter of the Box-Cox transformation, as well as an alternative method to determine plausible values for it. The former is accomplished by defining a grid of values for λ and further perform a normality test on the λ -transformed data. The optimum value of λ, say λ * , is such that the p-value from the normality test is the highest. The set of plausible values is determined using the inverse probability method after plotting the p-values against the values of λ on the grid. Our methodology is illustrated with two real-world data sets. Furthermore, a simulation study suggests that our method improves the symmetry, kurtosis and, hence, the normality of data, making it a feasible alternative to the traditional Box-Cox transformation.

  19. Comparison of two bond strength testing methodologies for bilayered all-ceramics

    NARCIS (Netherlands)

    Dundar, Mine; Ozcan, Mutlu; Gokce, Bulent; Comlekoglu, Erhan; Leite, Fabiola; Valandro, Luiz Felipe

    Objectives. This study compared the shear bond strength (SBS) and microtensile (MTBS) testing methodologies for core and veneering ceramics in four types of all-ceramic systems. Methods. Four different ceramic veneer/core combinations, three of which were feldspathic and the other a fluor-apatite to

  20. The fracture strength by a torsion test at the implant-abutment interface.

    Science.gov (United States)

    Watanabe, Fumihiko; Hiroyasu, Kazuhiko; Ueda, Kazuhiko

    2015-12-01

    Fractured connections between implants and implant abutments or abutment screws are frequently encountered in a clinical setting. The purpose of this study was to investigate fracture strength using a torsion test at the interface between the implant and the abutment. Thirty screw-type implant with diameters of 3.3, 3.8, 4.3, 5.0, and 6.0 mm were submitted to a torsion test. Implants of each size were connected to abutments with abutment screws tightened to 20 N · cm. Mechanical stress was applied with a rotational speed of 3.6 °/min until fracture occurred, and maximum torque (fracture torque) and torsional yield strength were measured. The mean values were calculated and then compared using Tukey's test. The abutments were then removed, and the implant-abutment interfaces were examined using a scanning electron microscope (SEM). No significant differences in mean fracture torque were found among 3.3, 3.8, and 4.3 mm-diameter implants, but significant differences were found between these sizes and 5.0 and 6.0 mm-diameter implants (p abutment corresponding to the internal notches of the implant body had been destroyed. Smaller diameter implants demonstrated lower fracture torque and torsional yield strength than implants with larger diameters. In internal tube-in-tube connections, three abutment projections corresponding to rotation-prevention notches were destroyed in each implant.

  1. A RESEARCH ON HEALTHY LIVING BEHAVIORS OF ARCHERY COACHES AND BOXING COACHES

    Directory of Open Access Journals (Sweden)

    Ziya Bahadır

    2014-07-01

    Full Text Available The aim of the research was to assess healthy living behaviors of archery coaches and boxing coaches in terms of sportive branch, sportive experience and gender. The study was conducted with boxing coaches (n=119 and archery coaches (n=131. As the data collection tool; “ The Health - Promoting Lifestyle Profile II (HPLP - II which was developed by Walker et al . and validity and reliability tests of which were performed by Bahar et al . (2008 was employed. In the study; it was found out that mean score of boxing coaches on P hysical activity subscale was higher than archery coaches . Besides; no statistically significant difference s existed between archery coaches and boxing coaches in terms of gender and sportive experience.

  2. Modified forelimb grip strength test detects aging-associated physiological decline in skeletal muscle function in male mice.

    Science.gov (United States)

    Takeshita, Hikari; Yamamoto, Koichi; Nozato, Satoko; Inagaki, Tadakatsu; Tsuchimochi, Hirotsugu; Shirai, Mikiyasu; Yamamoto, Ryohei; Imaizumi, Yuki; Hongyo, Kazuhiro; Yokoyama, Serina; Takeda, Masao; Oguro, Ryosuke; Takami, Yoichi; Itoh, Norihisa; Takeya, Yasushi; Sugimoto, Ken; Fukada, So-Ichiro; Rakugi, Hiromi

    2017-02-08

    The conventional forelimb grip strength test is a widely used method to assess skeletal muscle function in rodents; in this study, we modified this method to improve its variability and consistency. The modified test had lower variability among trials and days than the conventional test in young C57BL6 mice, especially by improving the variabilities in male. The modified test was more sensitive than the conventional test to detect a difference in motor function between female and male mice, or between young and old male mice. When the modified test was performed on male mice during the aging process, reduction of grip strength manifested between 18 and 24 months of age at the group level and at the individual level. The modified test was similar to the conventional test in detecting skeletal muscle dysfunction in young male dystrophic mice. Thus, the modified forelimb grip strength test, with its improved validity and reliability may be an ideal substitute for the conventional method.

  3. The three-box paradox revisited

    International Nuclear Information System (INIS)

    Ravon, Tamar; Vaidman, Lev

    2007-01-01

    The classical three-box paradox of Kirkpatrick (2003 J. Phys. A: Math. Gen. 36 4891) is compared to the original quantum three-box paradox of Aharonov and Vaidman (1991 J. Phys. A: Math. Gen. 24 2315). It is argued that the quantum three-box experiment is a 'quantum paradox' in the sense that it is an example of a classical task which cannot be accomplished using classical means, but can be accomplished using quantum devices. It is shown that Kirkpatrick's card game is analogous to a different game with a particle in three boxes which does not contain paradoxical features

  4. Shear punch and microhardness tests for strength and ductility measurements

    International Nuclear Information System (INIS)

    Lucas, G.E.; Odette, G.R.; Sheckherd, J.W.

    1983-01-01

    In response to the requirements of the fusion reactor materials development program for small-scale mechanical property tests, two techniques have been developed, namely ball microhardness and shear punch tests. The ball microhardness test is based on the repeated measurement at increasing loads of the chordal diameter of an impression made by a spherical penetrator. A correlation has been developed to predict the constitutive relation of the test material from these data. In addition, the indentation pile-up geometry can be analyzed to provide information on the homogeneity of plastic flow in the test material. The shear punch test complements the microhardness test. It is based on blanking a circular disk from a fixed sheet metal specimen. The test is instrumented to provide punch load-displacement data, and these data can be used to determine flow properties of the test material such as yield stress, ultimate tensile strength, work-hardening exponent, and reduction of area

  5. THE EFFICACY OF ANGLE-MATCHED ISOKINETIC KNEE FLEXOR AND EXTENSOR STRENGTH PARAMETERS IN PREDICTING AGILITY TEST PERFORMANCE.

    Science.gov (United States)

    Greig, Matt; Naylor, James

    2017-10-01

    Agility is a fundamental performance element in many sports, but poses a high risk of injury. Hierarchical modelling has shown that eccentric hamstring strength is the primary determinant of agility performance. The purpose of this study was to investigate the relationship between knee flexor and extensor strength parameters and a battery of agility tests. Controlled laboratory study. Nineteen recreational intermittent games players completed an agility battery and isokinetic testing of the eccentric knee flexors (eccH) and concentric knee extensors (conQ) at 60, 180 and 300°·s -1 . Peak torque and the angle at which peak torque occurred were calculated for eccH and conQ at each speed. Dynamic control ratios (eccH:conQ) and fast:slow ratios (300:60) were calculated using peak torque values, and again using angle-matched data, for eccH and conQ. The agility test battery differentiated linear vs directional changes and prescriptive vs reactive tasks. Linear regression showed that eccH parameters were generally a better predictor of agility performance than conQ parameters. Stepwise regression showed that only angle-matched strength ratios contributed to the prediction of each agility test. Trdaitionally calculated strength ratios using peak torque values failed to predict performance. Angle-matched strength parameters were able to account for 80% of the variation in T-test performance, 70% of deceleration distance, 55% of 10m sprint performance, and 44% of reactive change of direction speed. Traditionally calculated strength ratios failed to predict agility performance, whereas angle-matched strength ratios had better predictive ability and featured in a predictive stepwise model for each agility task. 2c.

  6. IMPROVED, FAVORABLE FOR ENVIRONMENT POLYURETHANE COLD-BOX-PROCESS (COLD BOX «HUTTENES-ALBERTUS» .

    Directory of Open Access Journals (Sweden)

    A. Sergini

    2005-01-01

    Full Text Available The results of the laboratory and industrial investigations, the purpose of which is improvement of the classical Cold-box-process, i.e. the process of the slugs hardening in cold boxes, are presented.

  7. 49 CFR 192.505 - Strength test requirements for steel pipeline to operate at a hoop stress of 30 percent or more...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Strength test requirements for steel pipeline to...: MINIMUM FEDERAL SAFETY STANDARDS Test Requirements § 192.505 Strength test requirements for steel pipeline... as provided in paragraph (e) of this section, the strength test must be conducted by maintaining the...

  8. Reconciling White-Box and Black-Box Perspectives on Behavioral Self-adaptation

    DEFF Research Database (Denmark)

    Bruni, Roberto; Corradini, Andrea; Gadducci, Fabio

    2015-01-01

    This paper proposes to reconcile two perspectives on behavioral adaptation commonly taken at different stages of the engineering of autonomic computing systems. Requirements engineering activities often take a black-box perspective: A system is considered to be adaptive with respect to an environ......This paper proposes to reconcile two perspectives on behavioral adaptation commonly taken at different stages of the engineering of autonomic computing systems. Requirements engineering activities often take a black-box perspective: A system is considered to be adaptive with respect...... to an environment whenever the system is able to satisfy its goals irrespectively of the environment perturbations. Modeling and programming engineering activities often take a white-box perspective: A system is equipped with suitable adaptation mechanisms and its behavior is classified as adaptive depending...

  9. Decommissioning a small glove box

    International Nuclear Information System (INIS)

    Bond, R.D.; McSherry, K.

    1985-11-01

    An account is given of dismantling a fuel fabrication glove box using simple tooling. The fissile content of the box was first measured by several non-destructive techniques. After cleaning, the box was dismantled using hand tools and finally packed for disposal. A record of operator radiation doses, the time taken for each stage of the operation and packing information is given. (author)

  10. A Finite Segment Method for Skewed Box Girder Analysis

    Directory of Open Access Journals (Sweden)

    Xingwei Xue

    2018-01-01

    Full Text Available A finite segment method is presented to analyze the mechanical behavior of skewed box girders. By modeling the top and bottom plates of the segments with skew plate beam element under an inclined coordinate system and the webs with normal plate beam element, a spatial elastic displacement model for skewed box girder is constructed, which can satisfy the compatibility condition at the corners of the cross section for box girders. The formulation of the finite segment is developed based on the variational principle. The major advantage of the proposed approach, in comparison with the finite element method, is that it can simplify a three-dimensional structure into a one-dimensional structure for structural analysis, which results in significant saving in computational times. At last, the accuracy and efficiency of the proposed finite segment method are verified by a model test.

  11. Validation and Reliability of a Novel Test of Upper Body Isometric Strength

    Directory of Open Access Journals (Sweden)

    Bellar David

    2015-09-01

    Full Text Available The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4% volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a “push-up” style position while tethered (stainless steel chain to a load cell (high frequency anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98 suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001 with all predictor variables attaining significance in the model (p<0.05. Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001. Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment.

  12. Validation and Reliability of a Novel Test of Upper Body Isometric Strength

    Science.gov (United States)

    Bellar, David; Marcus, Lena; Judge, Lawrence W.

    2015-01-01

    The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a “push-up” style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (p<0.05). Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment. PMID:26557203

  13. Impact attenuation of protective boxing and taekwondo headgear.

    Science.gov (United States)

    O'Sullivan, David M; Fife, Gabriel P

    2016-11-01

    This study aimed to compare the impact attenuation performance of boxing and taekwondo headgear in terms of peak linear and rotational acceleration. To measure the impact attenuation of headgear, a standardized (American Society for Testing and Materials (ASTM) F-2397) martial arts headgear striker was used to impart impacts to a 50th Percentile Male Hybrid III Crash Test Dummy head and neck complex. Two boxing (Adidas and Greenhill) and two taekwondo (Adidas and Nike) headgear, approved by the Association Internationale de Boxe Amateur and the World Taekwondo Federation (WTF), were selected. Each of the selected headgear was fitted to the Hybrid III head and subsequently subjected to five impacts at the front and side with a maximum impact interim time of 60 seconds by the rotating striker at 8 ± 0.3 m/s. Linear and rotational acceleration were recorded at 10,000 Hz. There were significant interactions of the impact location and brand on the rotational acceleration, F(3,40) = 6.7, p < .05. There were significant main effects of both impact location F(1,40) = 9.07, p < .05 and headgear brand F(3,40) = 9.9, p < .05 on the linear acceleration. Pairwise comparisons show significant differences between the front and side for both linear and rotational acceleration. The headgear tested failed the ASTM high impact test requirement to reduce the linear acceleration to below a threshold of 150 g. Further development of headgear to reduce impact linear and rotational acceleration magnitudes should be called for by the relevant sport governing bodies and initiated by headgear manufactures.

  14. Yield Strength Testing in Human Cadaver Nasal Septal Cartilage and L-Strut Constructs.

    Science.gov (United States)

    Liu, Yuan F; Messinger, Kelton; Inman, Jared C

    2017-01-01

    To our knowledge, yield strength testing in human nasal septal cartilage has not been reported to date. An understanding of the basic mechanics of the nasal septum may help surgeons decide how much of an L-strut to preserve and how much grafting is needed. To determine the factors correlated with yield strength of the cartilaginous nasal septum and to explore the association between L-strut width and thickness in determining yield strength. In an anatomy laboratory, yield strength of rectangular pieces of fresh cadaver nasal septal cartilage was measured, and regression was performed to identify the factors correlated with yield strength. To measure yield strength in L-shaped models, 4 bonded paper L-struts models were constructed for every possible combination of the width and thickness, for a total of 240 models. Mathematical modeling using the resultant data with trend lines and surface fitting was performed to quantify the associations among L-strut width, thickness, and yield strength. The study dates were November 1, 2015, to April 1, 2016. The factors correlated with nasal cartilage yield strength and the associations among L-strut width, thickness, and yield strength in L-shaped models. Among 95 cartilage pieces from 12 human cadavers (mean [SD] age, 67.7 [12.6] years) and 240 constructed L-strut models, L-strut thickness was the only factor correlated with nasal septal cartilage yield strength (coefficient for thickness, 5.54; 95% CI, 4.08-7.00; P cadaver nasal septal cartilage, L-strut thickness was significantly associated with yield strength. In a bonded paper L-strut model, L-strut thickness had a more important role in determining yield strength than L-strut width. Surgeons should consider the thickness of potential L-struts when determining the amount of cartilaginous septum to harvest and graft. NA.

  15. Evaluation of susceptibility of high strength steels to delayed fracture by using cyclic corrosion test and slow strain rate test

    International Nuclear Information System (INIS)

    Li Songjie; Zhang Zuogui; Akiyama, Eiji; Tsuzaki, Kaneaki; Zhang Boping

    2010-01-01

    To evaluate susceptibilities of high strength steels to delayed fracture, slow strain rate tests (SSRT) of notched bar specimens of AISI 4135 with tensile strengths of 1300 and 1500 MPa and boron-bearing steel with 1300 MPa have been performed after cyclic corrosion test (CCT). During SSRT the humidity around the specimen was kept high to keep absorbed diffusible hydrogen. The fracture stresses of AISI 4135 steels decreased with increment of diffusible hydrogen content which increased with CCT cycles. Their delayed fracture susceptibilities could be successfully evaluated in consideration of both influence of hydrogen content on mechanical property and hydrogen entry.

  16. Evaluation of susceptibility of high strength steels to delayed fracture by using cyclic corrosion test and slow strain rate test

    Energy Technology Data Exchange (ETDEWEB)

    Li Songjie [School of Materials Science and Engineering, University of Science and Technology Beijing, No. 30 Xueyuan Road, Hidian Zone, Beijing 100083 (China); Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Zhang Zuogui [Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Akiyama, Eiji [Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan)], E-mail: AKIYAMA.Eiji@nims.go.jp; Tsuzaki, Kaneaki [Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Zhang Boping [School of Materials Science and Engineering, University of Science and Technology Beijing, No. 30 Xueyuan Road, Hidian Zone, Beijing 100083 (China)

    2010-05-15

    To evaluate susceptibilities of high strength steels to delayed fracture, slow strain rate tests (SSRT) of notched bar specimens of AISI 4135 with tensile strengths of 1300 and 1500 MPa and boron-bearing steel with 1300 MPa have been performed after cyclic corrosion test (CCT). During SSRT the humidity around the specimen was kept high to keep absorbed diffusible hydrogen. The fracture stresses of AISI 4135 steels decreased with increment of diffusible hydrogen content which increased with CCT cycles. Their delayed fracture susceptibilities could be successfully evaluated in consideration of both influence of hydrogen content on mechanical property and hydrogen entry.

  17. Reliability, Validity, and Sensitivity of a Novel Smartphone-Based Eccentric Hamstring Strength Test in Professional Football Players.

    Science.gov (United States)

    Lee, Justin W Y; Cai, Ming-Jing; Yung, Patrick S H; Chan, Kai-Ming

    2018-05-01

    To evaluate the test-retest reliability, sensitivity, and concurrent validity of a smartphone-based method for assessing eccentric hamstring strength among male professional football players. A total of 25 healthy male professional football players performed the Chinese University of Hong Kong (CUHK) Nordic break-point test, hamstring fatigue protocol, and isokinetic hamstring strength test. The CUHK Nordic break-point test is based on a Nordic hamstring exercise. The Nordic break-point angle was defined as the maximum point where the participant could no longer support the weight of his body against gravity. The criterion for the sensitivity test was the presprinting and postsprinting difference of the Nordic break-point angle with a hamstring fatigue protocol. The hamstring fatigue protocol consists of 12 repetitions of the 30-m sprint with 30-s recoveries between sprints. Hamstring peak torque of the isokinetic hamstring strength test was used as the criterion for validity. A high test-retest reliability (intraclass correlation coefficient = .94; 95% confidence interval, .82-.98) was found in the Nordic break-point angle measurements. The Nordic break-point angle significantly correlated with isokinetic hamstring peak torques at eccentric action of 30°/s (r = .88, r 2  = .77, P hamstring strength measures among male professional football players.

  18. Design report for shielded glove box

    International Nuclear Information System (INIS)

    Ku, J. H.; Lee, J. C.; Seo, K. S.; Bang, K. S.; Lee, D. W.; Kim, J. H.; Min, D. K.; Park, S. W.

    1999-05-01

    For the examination of spent fuels and high radioactive specimens using a specially equipped scanning electron microscope, a shielded glove box was designed and constructed at PIE facility of KAERI. This glove box consisted of shielding walls, containment box, lead glasses, manipulators, gloves, ventilation systems, doors, hot-cell specimen cask adapter, etc. It was emphasized that both the easy operation and radiation safety are important factors in the shielded glove box were installed also considered as a important factor to build the basic concept of the assembling. Two sliding doors and one hinge-type door were installed for the easy installation, operation and maintenance of scanning electron microscope. Containment box which confines the radioactive material into the box consisted of reinforced transparent glasses, aluminum frames and stainless steel plate liner. Therefore everything beyond the containment box can be seen through the lead glass which installed at the front shielding wall. All shielding walls and doors were introduced separately into the room and assembled by bolting. (author). 3 refs., 5 tabs., 18 figs

  19. Modification of Bonding Strength Test of WC HVOF Thermal Spray Coating on Rocket Nozzle

    Directory of Open Access Journals (Sweden)

    Bondan Sofyan

    2010-10-01

    Full Text Available One way to reduce structural weight of RX-100 rocket is by modifying the nozzle material and processing. Nozzle is the main target in weight reduction due to the fact that it contributes 30 % to the total weight of the structur. An alternative for this is by substitution of massive graphite, which is currently used as thermal protector in the nozzle, with thin layer of HVOF (High Velocity Oxy-Fuel thermal spray layer. This paper presents the characterization of nozzle base material as well as the modification of bonding strength test, by designing additional jig to facilitate testing processes while maintaining level of test accuracy. The results showed that the material used for  RX-100 rocket nozzle is confirmed to be S45C steel. Modification of the bonding strength test was conducted by utilizing chains, which improve test flexibility and maintains level of accuracy of the test.

  20. Box-particle probability hypothesis density filtering

    OpenAIRE

    Schikora, M.; Gning, A.; Mihaylova, L.; Cremers, D.; Koch, W.

    2014-01-01

    This paper develops a novel approach for multitarget tracking, called box-particle probability hypothesis density filter (box-PHD filter). The approach is able to track multiple targets and estimates the unknown number of targets. Furthermore, it is capable of dealing with three sources of uncertainty: stochastic, set-theoretic, and data association uncertainty. The box-PHD filter reduces the number of particles significantly, which improves the runtime considerably. The small number of box-p...

  1. Degradation in PV Encapsulation Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David; Annigoni, Eleonora; Ballion, Amal; Bokria, Jayesh G.; Bruckman, Laura S.; Burns, David M.; Chen, Xinxin; Feng, Jiangtao; French, Roger H.; Fowler, Sean; Honeker, Christian C.; Kempe, Michael; Khonkar, Hussam; Kohl, Michael; Perret-Aebi, Laure-Emmanuelle; Phillips, Nancy H.; Scott, Kurt P.; Sculati-Meillaud, Fanny; Wohlgemuth, John

    2016-06-06

    Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

  2. Familiarization, validity and smallest detectable difference of the isometric squat test in evaluating maximal strength.

    Science.gov (United States)

    Drake, David; Kennedy, Rodney; Wallace, Eric

    2018-02-06

    Isometric multi-joint tests are considered reliable and have strong relationships with 1RM performance. However, limited evidence is available for the isometric squat in terms of effects of familiarization and reliability. This study aimed to assess, the effect of familiarization, stability reliability, determine the smallest detectible difference, and the correlation of the isometric squat test with 1RM squat performance. Thirty-six strength-trained participants volunteered to take part in this study. Following three familiarization sessions, test-retest reliability was evaluated with a 48-hour window between each time point. Isometric squat peak, net and relative force were assessed. Results showed three familiarizations were required, isometric squat had a high level of stability reliability and smallest detectible difference of 11% for peak and relative force. Isometric strength at a knee angle of ninety degrees had a strong significant relationship with 1RM squat performance. In conclusion, the isometric squat is a valid test to assess multi-joint strength and can discriminate between strong and weak 1RM squat performance. Changes greater than 11% in peak and relative isometric squat performance should be considered as meaningful in participants who are familiar with the test.

  3. Effects of repeated vibratory stimulation of wrist and elbow flexors on hand dexterity, strength, and sensory function in patients with chronic stroke: a pilot study.

    Science.gov (United States)

    Choi, Won-Ho

    2017-04-01

    [Purpose] The aim of this study was to investigate the effects of repeated vibratory stimulation to muscles related to hand functions on dexterity, strength, and sensory function in patients with chronic stroke. [Subjects and Methods] A total of 10 stroke patients with hemiplegia participated in this study. They were divided into two groups: a) Experimental and b) Control, with five randomly selected subjects for each group. The experimental group received vibratory stimulation, while the control group received the traditional physical therapy. Both interventions were performed for 30 minutes each session, three times a week for four weeks. [Results] There was a significant within-group improvement in the box and block test results in both groups for dexterity. Grip strength improved in both groups but the improvement was not statistically significant. [Conclusion] The vibratory stimulation activated the biceps brachii and flexor carpi radialis, which increased dexterity to grasp and lift the box and block from the surface. Therefore, repeated vibratory stimulation to muscles related to hand functions improved hand dexterity equality to the traditional physical therapy in patients with chronic stroke.

  4. Residual strength and crack propagation tests on C-130 airplane center wings with service-imposed fatigue damage

    Science.gov (United States)

    Snider, H. L.; Reeder, F. L.; Dirkin, W. J.

    1972-01-01

    Fourteen C-130 airplane center wings, each containing service-imposed fatigue damage resulting from 4000 to 13,000 accumulated flight hours, were tested to determine their fatigue crack propagation and static residual strength characteristics. Eight wings were subjected to a two-step constant amplitude fatigue test prior to static testing. Cracks up to 30 inches long were generated in these tests. Residual static strengths of these wings ranged from 56 to 87 percent of limit load. The remaining six wings containing cracks up to 4 inches long were statically tested as received from field service. Residual static strengths of these wings ranged from 98 to 117 percent of limit load. Damage-tolerant structural design features such as fastener holes, stringers, doublers around door cutouts, and spanwise panel splices proved to be effective in retarding crack propagation.

  5. The influence of using volcanic ash and lime ash as filler on compressive strength in self compacting concrete

    Science.gov (United States)

    Karolina, Rahmi; Panatap Simanjuntak, Murydrischy

    2018-03-01

    Self Compacting Concrete (SCC) is a technology which is developing today in which concrete solidifies by itself without using vibrator. Casting conventional concrete which has a lot of reinforcement bars sometimes finds difficulty in achieving optimal solidity. The method used to solve this problem is by using SCC technology. SCC was made by using filler, volcanic ash, and lime ash as the filling materials so that the concrete became more solid and hollow space could be filled up. The variation of using these two materials was 10%, 15%, 20%, and 25% of the cementitious mass and using 1% of superplasticizer from cementitious material. The supporting testing was done by using the test when the concrete was still fluid and when it was solid. Malleable concrete was tested by using EFNARC 2002 standard in slump flow test, v-funnel test, l-shaped box test, and j-ring test to obtain filling ability and passing ability. In this malleable lime concrete test, there was the decrease, compared with normal SCC concrete without adding volcanic ash and lime ash. Testing was also done in solid concrete in compressive strength, tensile strength, and concrete absorption. The result of the testing showed that the optimum tensile strength in Variation 1, without volcanic ash and lime ash – with 1% of superplasticizer was 39.556 MPa, the optimum tensile strength in Variation 1, without volcanic ash and lime ash- with 1% of super-plasticizer was 3.563 MPa, while the value of optimum absorption which occurred in Variation 5 (25% of volcanic ash + 25% of lime ash + 50% of cement + 1% of superplasticizer) was 1.313%. This was caused by the addition of volcanic ash and lime ash which had high water absorption.

  6. Channel box dimension measuring method

    International Nuclear Information System (INIS)

    Oshima, Hirotake; Jo, Hiroto.

    1994-01-01

    The present invention provides a method for measuring the entire length of a channel box of a fuel assembly of a BWR type reactor. Namely, four sensors are used as one set that generate ultrasonic waves from oblique upper portion, oblique lower portion, upper portion and lower portion of the channel box respectively. The distances between the four sensors and each of the portions of the channel box are measured respectively for both of a reference member and a member to be measured. The entire length of the channel box is measured by calculating the measured values and the angles of the obliquely disposed sensors according to a predetermined formula. According to the method of the present invention, the inclination of the channel box to be measured can be corrected. In addition, accuracy of the measurement is improved and the measuring time is saved as well as the measuring device and operation can be simplified. (I.S.)

  7. Shaping 3-D boxes

    DEFF Research Database (Denmark)

    Stenholt, Rasmus; Madsen, Claus B.

    2011-01-01

    Enabling users to shape 3-D boxes in immersive virtual environments is a non-trivial problem. In this paper, a new family of techniques for creating rectangular boxes of arbitrary position, orientation, and size is presented and evaluated. These new techniques are based solely on position data...

  8. Striking dynamics and kinetic properties of boxing and MMA gloves

    Directory of Open Access Journals (Sweden)

    Benjamin Lee

    2014-08-01

    Full Text Available With the growing popularity of Mixed Martial Arts (MMA as a competitive sport, questions regarding the dynamic response and properties of MMA gloves arise. High-energy impacts from punches are very similar to boxing yet MMA competition requires the use of 4 oz fingerless glove, compared to the larger full enclosure boxing glove. This work assessed the kinetic properties and strike dynamics of MMA gloves and compared findings with traditional boxing gloves. Gloves mounted on a molded fist were impacted repetitively on an instrumental anvil designed for impact, over a 5 hour period resulting in 10,000 continuous and consistent strikes. Kinetic data from impacts were sampled at the beginning of the data collection and subsequently every 30 minutes (every 1,000 strikes. MMA gloves produced 4-5 times greater peak force and 5 times faster load rate compared to the boxing glove. However, MMA gloves also showed signs of material fatigue, with peak force increasing by 35% and rate of loading increasing by 60% over the duration of the test. Boxing glove characteristics did deteriorate but to a lesser extent. In summary, the kinetic properties of MMA glove differed substantially from the boxing glove resulting in impacts characterized by higher peak forces and more rapid development of force. Material properties including stiffness and thickness play a role in the kinetic characteristics upon impact, and can be inferred to alter injury mechanisms of blunt force trauma.

  9. HYBRID CONTINUUM-DISCONTINUUM MODELLING OF ROCK FRACUTRE PROCESS IN BRAZILIAN TENSILE STRENGTH TEST

    Directory of Open Access Journals (Sweden)

    Huaming An

    2017-10-01

    Full Text Available A hybrid continuum-discontinuum method is introduced to model the rock failure process in Brazilian tensile strength (BTS test. The key component of the hybrid continuum-discontinuum method, i.e. transition from continuum to discontinuum through fracture and fragmentation, is introduced in detail. A laboratory test is conducted first to capture the rock fracture pattern in the BTS test while the tensile strength is calculated according to the peak value of the loading forces. Then the proposed method is used to model the rock behaviour during BTS test. The stress propagation is modelled and compared with those modelled by finite element method in literatures. In addition, the crack initiation and propagation are captured and compared with the facture patter in laboratory test. Moreover, the force-loading displacement curve is obtained which represents a typical brittle material failure process. Furthermore, the stress distributions along the vertical direction are compared with the theoretical solution. It is concluded that the hybrid continuum-discontinuum method can model the stress propagation process and the entire rock failure process in BTS test. The proposed method is a valuable numerical tool for studying the rock behaviour involving the fracture and fragmentation processes.

  10. Impact of pain reported during isometric quadriceps muscle strength testing in people with knee pain: data from the osteoarthritis initiative.

    Science.gov (United States)

    Riddle, Daniel L; Stratford, Paul W

    2011-10-01

    Muscle force testing is one of the more common categories of diagnostic tests used in clinical practice. Clinicians have little evidence to guide interpretations of muscle force tests when pain is elicited during testing. The purpose of this study was to examine the construct validity of isometric quadriceps muscle strength tests by determining whether the relationship between maximal isometric quadriceps muscle strength and functional status was influenced by pain during isometric testing. A cross-sectional design was used. Data from the Osteoarthritis Initiative were used to identify 1,344 people with unilateral knee pain and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain subscale scores of 1 or higher on the involved side. Measurements of maximal isometric quadriceps strength and ratings of pain during isometric testing were collected. Outcome variables were WOMAC physical function subscale, 20-m walk test, 400-m walk test, and a repeated chair stand test. Multiple regression models were used to determine whether pain during testing modified or confounded the relationship between strength and functional status. Pearson r correlations among the isometric quadriceps strength measures and the 4 outcome measures ranged from -.36 (95% confidence interval=-.41, -.31) for repeated chair stands to .36 (95% confidence interval=.31, .41) for the 20-m walk test. In the final analyses, neither effect modification nor confounding was found for the repeated chair stand test, the 20-m walk test, the 400-m walk test, or the WOMAC physical function subscale. Moderate or severe pain during testing was weakly associated with reduced strength, but mild pain was not. The disease spectrum was skewed toward mild or moderate symptoms, and the pain measurement scale used during muscle force testing was not ideal. Given that the spectrum of the sample was skewed toward mild or moderate symptoms and disease, the data suggest that isometric quadriceps muscle

  11. DSMC simulations of vapor transport toward development of the lithium vapor box divertor concept

    Science.gov (United States)

    Jagoe, Christopher; Schwartz, Jacob; Goldston, Robert

    2016-10-01

    The lithium vapor divertor box concept attempts to achieve volumetric dissipation of the high heat efflux from a fusion power system. The vapor extracts the heat of the incoming plasma by ionization and radiation, while remaining localized in the vapor box due to differential pumping based on rapid condensation. Preliminary calculations with lithium vapor at densities appropriate for an NSTX-U-scale machine give Knudsen numbers between 0.01 and 1, outside both the range of continuum fluid dynamics and of collisionless Monte Carlo. The direct-simulation Monte Carlo (DSMC) method, however, can simulate rarefied gas flows in this regime. Using the solver contained in the OpenFOAM package, pressure-driven flows of water vapor will be analyzed. The use of water vapor in the relevant range of Knudsen number allows for a flexible similarity experiment to verify the reliability of the code before moving to tests with lithium. The simulation geometry consists of chains of boxes on a temperature gradient, connected by slots with widths that are a representative fraction of the dimensions of the box. We expect choked flow, sonic shocks, and order-of-magnitude pressure and density drops from box to box, but this expectation will be tested in the simulation and then experiment. This work is supported by the Princeton Environmental Institute.

  12. The Performance of Calcium Silicate Board Partition Fireproof Drywall Assembly with Junction Box under Fire

    Directory of Open Access Journals (Sweden)

    Yinuo Wang

    2015-01-01

    Full Text Available This study uses a metal stud partition fireproof drywall measuring 83 mm in thickness as a test specimen to explore the impact of an embedded junction box on the firefighting performance of the wall through one time of standard fire test on a 300 cm × 300 cm area and five times of standard fire test on a 120 cm × 120 cm area. The results show that the quality of calcium silicate board plays a big role in the fireproof effectiveness. The embedded junction box located on the backside of the fire can reduce the effectiveness of the wall, especially the area above the socket. The thickness of rock wool may increase the performance, but in a limited rate. External junction box may not impact the fireproofing performance of the wall but it still possesses some safety risks. An embedded junction box measuring 101 × 55 mm could already damage the fire compartment, and in reality there may be more complicated situations that should be noted and improved.

  13. Innovations in Los Alamos alpha box design

    International Nuclear Information System (INIS)

    Ledbetter, J.M.; Dowler, K.E.; Cook, J.H.

    1985-01-01

    Destructive examinations of irradiated fuel pins containing plutonium fuel must be performed in shielded hot cells with strict provisions for containing the plutonium. Alpha boxes provide containment for the plutonium, toxic fission products, and other hazardous highly radioactive materials. The alpha box contains windows for viewing and a variety of transfer systems specially designed to allow transfers in and out of the alpha box without spread of the hazardous materials that are contained in the box. Alpha boxes have been in use in the Wing 9 hot cells at Los Alamos National Laboratory for more than 20 years. Features of the newly designed alpha boxes are presented

  14. Probe and Sensors Development for Level Measurement of Fats, Oils and Grease in Grease Boxes

    Directory of Open Access Journals (Sweden)

    José Faria

    2016-09-01

    Full Text Available The wide spread of food outlets has become an environmental and sanitation infrastructure problem, due to Fats, Oils and Grease (FOG. A grease box is used at the industrials facilities to collect the FOG, in a specific time window, while its quality is good for recycling (e.g., biodiesel and it is economically valuable. After this period, it will be disposed at a cost. For the proper management of the grease boxes, it is necessary to know the quantity of FOG inside the boxes, which is a major problem, as the boxes are sealed and permanently filled with water. The lack of homogeneity of the FOG renders it not detectable by current probes for level detection in liquids. In this article, the design, development and testing of a set of probes for FOG level measurement, based on the principles used in sensors for the detection of liquids inside containers, is described. The most suitable probe, based on the capacitance principle, together with the necessary hardware and software modules for data acquisition and transmission, was developed and tested. After the development phase, the probe was integrated on a metropolitan system for FOG collection and grease box management in partnership with a grease box management company.

  15. Comparison of two test designs for evaluating the shear bond strength of resin composite cements.

    Science.gov (United States)

    Hu, M; Weiger, R; Fischer, J

    2016-02-01

    To compare a shear bond strength test for resin composite cements developed in order to better consider the shrinkage stress (here termed "Swiss shear test") with the shear test design according to ISO 29022. Four restorative materials (VITA Enamic (VE), VITA Suprinity (VS), Vitablocs Mark II (VM) and VITA YZ T (YZ)) served as substrate. VE, VS and VM were polished or etched. YZ was polished, sandblasted or etched. Specimens were either bonded according to the Swiss or the ISO shear test. RelyX Unicem 2 Automix, Maxcem Elite and PermaFlo DC were used as cements. Shear bond strength (SBS) was measured. Failure modes (adhesive, cohesive or mixed) were evaluated by means of SEM. Mean SBS values obtained with the Swiss shear test were significantly lower than those obtained with the ISO shear test. VE and VM exhibited similar SBS, values of VS were significantly higher. On etched surfaces VM and VE exhibited primarily cohesive failures, VS primarily adhesive failures. On polished substrates significantly lower bond strength values and exclusively adhesive failures were observed. YZ exhibited solely adhesive failures. Compared to polished YZ, SBS significantly increased after sandblasting and even more after etching. Only for adhesively failed specimens mean SBS values of Swiss and ISO shear test were strongly correlated. Both test designs showed the same ranking of test results. When adhesive failure occurred test results were strongly correlated. When cohesive failure was involved, both test designs did not provide reliable results. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  16. Study on partial overheat of the isolated phase busbar outlet box in Qinshan NPP phase Ⅱ

    International Nuclear Information System (INIS)

    Tang Fangxuan; Zhang Jian; Zeng Limin; Bao Yanxing; Zhang Lie; Yang Yuemin

    2013-01-01

    This paper recommended the structure of the isolated phase busbar outlet box installed in Qinshan II. The study on partial overheat of the outlet box shows that the ultimate causes are the loss of concentrated eddy current and short of cooling. So the improvement principles of 'distributing eddy current, cutting off inductive circle current and strengthening of ventilation' were determined. A new structure test outlet box was designed and manufactured, and the temperature rising experiment was carried out. Some alterations were made in the new structure outlet box, e.g. isolating materials were added between side plates of the upper outlet box, and also between the upper and lower outlet box. Two cooling blowers were added to the upper outlet box. After putting into operation, the hot-spot temperature of the new outlet box was greatly lowered down. Thus the operation environment was improved, and the operation safety ensured. It can be useful references for analyzing and dealing with similar problems. (authors)

  17. Complementarity in the Einstein-Bohr photon box

    NARCIS (Netherlands)

    Dieks, D.G.B.J.; Lam, S

    2008-01-01

    The Bohr-Einstein photon box thought experiment is a forerunner of the EPR experiment: a packet of radiation escapes from a box, and the box-plus-radiation state remains entangled. Hence, a measurement on the box makes a difference for the state of the far-away radiation long after its escape. This

  18. Test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy.

    Science.gov (United States)

    Savva, Christos; Giakas, Giannis; Efstathiou, Michalis; Karagiannis, Christos

    2014-01-01

    The purpose of this study was to evaluate the test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy (CR). A convenience sample of 19 participants (14 men and 5 women; mean ± SD age, 50.5 ± 12 years) with CR was measured using a Jamar hydraulic hand dynamometer by the same rater on 2 different testing sessions with an interval of 7 days between sessions. Data collection procedures followed standardized grip strength testing guidelines established by the American Society of Hand Therapists. During the repeated measures, patients were advised to rest their upper limb in the standardized arm position and encouraged to exert 3 maximum gripping efforts. The mean value of the 3 efforts (measured in kilogram force [Kgf]) was used for data analysis. The intraclass correlation coefficient, SEM, and the Bland-Altman plot were used to estimate test-retest reliability and measurement precision. Grip strength measurement in CR demonstrated an intraclass correlation coefficient of 0.976, suggesting excellent test-retest reliability. The small SEM in both testing sessions (SEM1, 2.41 Kgf; SEM2, 2.51 Kgf) as well as the narrow width of the 95% limits of agreements (95% limits of agreement, -4.9 to 4.4 Kgf) in the Bland-Altman plot reflected precise measurements of grip strength in both occasions. Excellent test-retest reliability for grip strength measurement was measured in patients with CR, demonstrating that a hydraulic hand dynamometer could be used as an outcome measure for these patients. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  19. Effect of mineral admixtures on kinetic property and compressive strength of self Compacting Concrete

    Science.gov (United States)

    Jagalur Mahalingasharma, Srishaila; Prakash, Parasivamurthy; Vishwanath, K. N.; Jawali, Veena

    2017-06-01

    This paper presents experimental investigations made on the influence of chemical, physical, morphological and mineralogical properties of mineral admixtures such as fly ash, ground granulate blast furnace slag, metakaoline and micro silica used as a replacement of cement in self compacting concrete on workability and compressive strength. Nineteen concrete mixes were cast by replacing with cement by fly ash or ground granulated blast furnace slag as binary blend at 30%, 40%, 50% and with addition of micro silica and metakaoline at 10% as a ternary blend with fly ash, ground granulated blast furnace slag and obtained results were compare with control mix. Water powder ratio 0.3 and super plasticizer dosage 1% of cementitious material was kept constant for all the mixes. The self compacting concrete tested for slump flow, V-funnel, L-Box, J-Ring, T50, and compressive strength on concrete cube were determined at age of 3, 7, 28, 56, 90 days.

  20. Dustproof cooling of the electrical box

    Directory of Open Access Journals (Sweden)

    Nemec Patrik

    2018-01-01

    Full Text Available In present are electrical boxes cooled by air through the intake hole on the bottom electrical box to the box space with electrotechnical elements and exhaust through the hole at the top to the surrounding by natural convection. This cooling method is effective but operate with the risk of contamination electrotechnical elements by dust sucking from surrounding air. The goal of this work is solution of the dustproof cooling of the electrical box by natural convection. The work deal with design of the device with the heat transfer by the phase change of the working fluid and experimental measuring its thermal performance at the cooling electrotechnical elements loaded by heat 1 200 W in the dustproof electrical box.

  1. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    Science.gov (United States)

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  2. Effect of curing and silanizing on composite repair bond strength using an improved micro-tensile test method.

    Science.gov (United States)

    Eliasson, Sigfus Thor; Dahl, Jon E

    2017-01-01

    Objectives: To evaluate the micro-tensile repair bond strength between aged and new composite, using silane and adhesives that were cured or left uncured when new composite was placed. Methods: Eighty Filtek Supreme XLT composite blocks and four control blocks were stored in water for two weeks and thermo-cycled. Sandpaper ground, etched and rinsed specimens were divided into two experimental groups: A, no further treatment and B, the surface was coated with bis-silane. Each group was divided into subgroups: (1) Adper Scotchbond Multi-Purpose, (2) Adper Scotchbond Multi-Purpose adhesive, (3) Adper Scotchbond Universal, (4) Clearfil SE Bond and (5) One Step Plus. For each adhesive group, the adhesive was (a) cured according to manufacturer's instructions or (b) not cured before repair. The substrate blocks were repaired with Filtek Supreme XLT. After aging, they were serially sectioned, producing 1.1 × 1.1 mm square test rods. The rods were prepared for tensile testing and tensile strength calculated at fracture. Type of fracture was examined under microscope. Results: Leaving the adhesive uncured prior to composite repair placement increased the mean tensile values statistically significant for all adhesives tested, with or without silane pretreatment. Silane surface treatment improved significantly ( p strength values for all adhesives, both for the cured and uncured groups. The mean strength of the control composite was higher than the strongest repair strength ( p strength. Not curing the adhesive before composite placement increased the tensile bond strength.

  3. Electrical shielding box measurement of the negative hydrogen beam from Penning ion gauge ion source.

    Science.gov (United States)

    Wang, T; Yang, Z; Dong, P; long, J D; He, X Z; Wang, X; Zhang, K Z; Zhang, L W

    2012-06-01

    The cold-cathode Penning ion gauge (PIG) type ion source has been used for generation of negative hydrogen (H(-)) ions as the internal ion source of a compact cyclotron. A novel method called electrical shielding box dc beam measurement is described in this paper, and the beam intensity was measured under dc extraction inside an electrical shielding box. The results of the trajectory simulation and dc H(-) beam extraction measurement were presented. The effect of gas flow rate, magnetic field strength, arc current, and extraction voltage were also discussed. In conclusion, the dc H(-) beam current of about 4 mA from the PIG ion source with the puller voltage of 40 kV and arc current of 1.31 A was extrapolated from the measurement at low extraction dc voltages.

  4. Box graphs and resolutions I

    Directory of Open Access Journals (Sweden)

    Andreas P. Braun

    2016-04-01

    Full Text Available Box graphs succinctly and comprehensively characterize singular fibers of elliptic fibrations in codimension two and three, as well as flop transitions connecting these, in terms of representation theoretic data. We develop a framework that provides a systematic map between a box graph and a crepant algebraic resolution of the singular elliptic fibration, thus allowing an explicit construction of the fibers from a singular Weierstrass or Tate model. The key tool is what we call a fiber face diagram, which shows the relevant information of a (partial toric triangulation and allows the inclusion of more general algebraic blowups. We shown that each such diagram defines a sequence of weighted algebraic blowups, thus providing a realization of the fiber defined by the box graph in terms of an explicit resolution. We show this correspondence explicitly for the case of SU(5 by providing a map between box graphs and fiber faces, and thereby a sequence of algebraic resolutions of the Tate model, which realizes each of the box graphs.

  5. Comparison of Geometrical Layouts for a Multi-Box Aerosol Model from a Single-Chamber Dispersion Study

    Directory of Open Access Journals (Sweden)

    Alexander C. Ø. Jensen

    2018-04-01

    Full Text Available Models are increasingly used to estimate and pre-emptively calculate the occupational exposure of airborne released particulate matter. Typical two-box models assume instant and fully mixed air volumes, which can potentially cause issues in cases with fast processes, slow air mixing, and/or large volumes. In this study, we present an aerosol dispersion model and validate it by comparing the modelled concentrations with concentrations measured during chamber experiments. We investigated whether a better estimation of concentrations was possible by using different geometrical layouts rather than a typical two-box layout. A one-box, two-box, and two three-box layouts were used. The one box model was found to underestimate the concentrations close to the source, while overestimating the concentrations in the far field. The two-box model layout performed well based on comparisons from the chamber study in systems with a steady source concentration for both slow and fast mixing. The three-box layout was found to better estimate the concentrations and the timing of the peaks for fluctuating concentrations than the one-box or two-box layouts under relatively slow mixing conditions. This finding suggests that industry-relevant scaled volumes should be tested in practice to gain more knowledge about when to use the two-box or the three-box layout schemes for multi-box models.

  6. Comparison of bond strength of different endodontic sealers to root dentin: An in vitro push-out test.

    Science.gov (United States)

    Madhuri, G Vijaya; Varri, Sujana; Bolla, Nagesh; Mandava, Pragna; Akkala, Lakshmi Swathi; Shaik, Jaheer

    2016-01-01

    To compare the bond strength of four different endodontic sealers to root dentin through push-out test design. Forty single-rooted teeth with completely formed apices were selected. Teeth were decoronated, and working length was determined. Instrumentation and irrigation were performed. The teeth were divided into four groups based upon the sealer used. Group 1: Bioceramic sealer (Endosequence), Group 2: Mineral trioxide aggregate (MTA) based sealer (MTA Fill apex), Group 3: Epoxy resin based sealer (MM-Seal), and Group 4: Dual cure resin-based sealer (Hybrid Root Seal). Manipulation and application of the sealer was done as per the manufacturer instructions. All the teeth were obturated using 6% gutta-percha. After obturation, each tooth was prepared for push-out test with root slices of 2 mm thickness using universal testing machine. The highest bond strength was found in Group 1 (Endosequence) (P strength was found in Group 2 (MTA Fill apex). Statistical analysis is done by two-way ANOVA and Newman-Keuls multiple post hoc. The push-out bond strength of Bioceramic sealer was highest followed by resin-based sealer and lowest bond strength was observed in MTA-based sealer.

  7. Plate forming and break down pizza box

    Science.gov (United States)

    Pantisano, Frank; Devine, Scott M.

    1992-01-01

    A standard corrugated paper pizza box is provided with slit cuts cut through the top panel of the pizza box in a shape to form four circular serving plates with a beveled raised edge and cross slit cuts through the bottom panel of the pizza box separating the box into four essentially equal portions for easy disposal.

  8. Injury risk in professional boxing.

    Science.gov (United States)

    Bledsoe, Gregory H; Li, Guohu; Levy, Fred

    2005-10-01

    Although a popular endeavor, boxing has fallen under increased scrutiny because of its association with traumatic brain injury. However, few studies have investigated the overall epidemiology of boxing injuries from representative samples, and no study has ever documented the incidence of injuries in female boxers. This study is a review of professional boxing data from the state of Nevada from September 2001 through March 2003. Medical and outcome data for all professional boxing matches occurring in Nevada between September 2001 and March 2003 (n = 524 matches) were analyzed on the basis of a pair-matched, case-control design. Cases were boxers who received an injury during the boxing matches. Boxers who were not injured served as control subjects. Both conditional and unconditional logistic regression models were used to assess risk factors for injury. The overall incidence rate of injury was 17.1 per 100 boxer-matches, or 3.4 per 100 boxer-rounds. Facial laceration accounted for 51% of all injuries, followed by hand injury (17%), eye injury (14%), and nose injury (5%). Male boxers were significantly more likely than female boxers to receive injuries (3.6 versus 1.2 per 100 boxer-rounds, P = 0.01). Male boxing matches also ended in knockouts and technical knockouts more often than did female matches (P boxing matches is high, particularly among male boxers. Superficial facial lacerations are the most common injury reported. Male boxers have a higher rate of knockout and technical knockouts than female boxers. Further research is necessary to determine the outcomes of injury, particularly the long-term neurologic outcome differences between sexes.

  9. Monitoring Instrument for X-Ray Box

    CERN Document Server

    Cifuentes Ospina, Alberto; Kuehn, Susanne; Schaepe, Steffen; CERN. Geneva. EP Department

    2017-01-01

    A humidity and temperature readout instrument has been designed and implemented in order to monitor the X-Ray Box used for testing the silicon detectors prototypes of the ITk. The sensors are connected to an Arduino Mega board equipped with 16 analog inputs and a serial port to a computer. A user-friendly software has been also designed in order to give an easy access to all measurements.

  10. Comparative Human and Automatic Evaluation of Glass-Box and Black-Box Approaches to Interactive Translation Prediction

    Directory of Open Access Journals (Sweden)

    Torregrosa Daniel

    2017-06-01

    Full Text Available Interactive translation prediction (ITP is a modality of computer-aided translation that assists professional translators by offering context-based computer-generated continuation suggestions as they type. While most state-of-the-art ITP systems follow a glass-box approach, meaning that they are tightly coupled to an adapted machine translation system, a black-box approach which does not need access to the inner workings of the bilingual resources used to generate the suggestions has been recently proposed in the literature: this new approach allows new sources of bilingual information to be included almost seamlessly. In this paper, we compare for the first time the glass-box and the black-box approaches by means of an automatic evaluation of translation tasks between related languages such as English–Spanish and unrelated ones such as Arabic–English and English–Chinese, showing that, with our setup, 20%–50% of keystrokes could be saved using either method and that the black-box approach outperformed the glass-box one in five out of six scenarios operating under similar conditions. We also performed a preliminary human evaluation of English to Spanish translation for both approaches. On average, the evaluators saved 10% keystrokes and were 4% faster with the black-box approach, and saved 15% keystrokes and were 12% slower with the glass-box one; but they could have saved 51% and 69% keystrokes respectively if they had used all the compatible suggestions. Users felt the suggestions helped them to translate faster and easier. All the tools used to perform the evaluation are available as free/open–source software.

  11. Evaluation of Key Dependent S-Box Based Data Security Algorithm using Hamming Distance and Balanced Output

    Directory of Open Access Journals (Sweden)

    Balajee Maram K.

    2016-02-01

    Full Text Available Data security is a major issue because of rapid evolution of data communication over unsecured internetwork. Here the proposed system is concerned with the problem of randomly generated S-box. The generation of S-box depends on Pseudo-Random-Number-Generators and shared-secret-key. The process of Pseudo-Random-Number-Generator depends on large prime numbers. All Pseudo-Random-Numbers are scrambled according to shared-secret-key. After scrambling, the S-box is generated. In this research, large prime numbers are the inputs to the Pseudo-Random-Number-Generator. The proposed S-box will reduce the complexity of S-box generation. Based on S-box parameters, it experimentally investigates the quality and robustness of the proposed algorithm which was tested. It yields better results with the S-box parameters like Hamming Distance, Balanced Output and Avalanche Effect and can be embedded to popular cryptography algorithms

  12. Episodic, generalized, and semantic memory tests: switching and strength effects.

    Science.gov (United States)

    Humphreys, Michael S; Murray, Krista L

    2011-09-01

    We continue the process of investigating the probabilistic paired associate paradigm in an effort to understand the memory access control processes involved and to determine whether the memory structure produced is in transition between episodic and semantic memory. In this paradigm two targets are probabilistically paired with a cue across a large number of short lists. Participants can recall the target paired with the cue in the most recent list (list specific test), produce the first of the two targets that have been paired with that cue to come to mind (generalised test), and produce a free association response (semantic test). Switching between a generalised test and a list specific test did not produce a switching cost indicating a general similarity in the control processes involved. In addition, there was evidence for a dissociation between two different strength manipulations (amount of study time and number of cue-target pairings) such that number of pairings influenced the list specific, generalised and the semantic test but amount of study time only influenced the list specific and generalised test. © 2011 Canadian Psychological Association

  13. Test-retest reliability and minimal detectable change scores for sit-to-stand-to-sit tests, the six-minute walk test, the one-leg heel-rise test, and handgrip strength in people undergoing hemodialysis.

    Science.gov (United States)

    Segura-Ortí, Eva; Martínez-Olmos, Francisco José

    2011-08-01

    Determining the relative and absolute reliability of outcomes of physical performance tests for people undergoing hemodialysis is necessary to discriminate between the true effects of exercise interventions and the inherent variability of this cohort. The aims of this study were to assess the relative reliability of sit-to-stand-to-sit tests (the STS-10, which measures the time [in seconds] required to complete 10 full stands from a sitting position, and the STS-60, which measures the number of repetitions achieved in 60 seconds), the Six-Minute Walk Test (6MWT), the one-leg heel-rise test, and the handgrip strength test and to calculate minimal detectable change (MDC) scores in people undergoing hemodialysis. This study was a prospective, nonexperimental investigation. Thirty-nine people undergoing hemodialysis at 2 clinics in Spain were contacted. Study participants performed the STS-10 (n=37), the STS-60 (n=37), and the 6MWT (n=36). At one of the settings, the participants also performed the one-leg heel-rise test (n=21) and the handgrip strength test (n=12) on both the right and the left sides. Participants attended 2 testing sessions 1 to 2 weeks apart. High intraclass correlation coefficients (≥.88) were found for all tests, suggesting good relative reliability. The MDC scores at 90% confidence intervals were as follows: 8.4 seconds for the STS-10, 4 repetitions for the STS-60, 66.3 m for the 6MWT, 3.4 kg for handgrip strength (force-generating capacity), 3.7 repetitions for the one-leg heel-rise test with the right leg, and 5.2 repetitions for the one-leg heel-rise test with the left leg. Limitations A limited sample of patients was used in this study. The STS-16, STS-60, 6MWT, one-leg heel rise test, and handgrip strength test are reliable outcome measures. The MDC scores at 90% confidence intervals for these tests will help to determine whether a change is due to error or to an intervention.

  14. Math in the Box

    Science.gov (United States)

    DeYoung, Mary J.

    2009-01-01

    This article describes how to make an origami paper box and explores the algebra, geometry, and other mathematics that unfolds. A set of origami steps that transforms the paper into an open box can hold mathematical surprises for both students and teachers. An origami lesson can engage students in an open-ended exploration of the relationship…

  15. ALUMINUM BOX BUNDLING PRESS

    Directory of Open Access Journals (Sweden)

    Iosif DUMITRESCU

    2015-05-01

    Full Text Available In municipal solid waste, aluminum is the main nonferrous metal, approximately 80- 85% of the total nonferrous metals. The income per ton gained from aluminum recuperation is 20 times higher than from glass, steel boxes or paper recuperation. The object of this paper is the design of a 300 kN press for aluminum box bundling.

  16. Jewelry boxes contaminated by Aspergillus oryzae: an occupational health risk?

    Science.gov (United States)

    Bellanger, Anne-Pauline; Roussel, Anaïs; Millon, Laurence; Delaforge, Marcel; Reboux, Gabriel

    2012-01-01

    In 2009, 100,000 jewelry boxes, manufactured in China, were delivered to a jewelry manufacturer in Besançon, France. All the boxes were contaminated by mold. Because the workers refused to handle these jewelry boxes, the company contacted our laboratory to determine how to deal with the problem. Three choices were available: (1) decontaminate the boxes, (2) return the boxes to the Chinese manufacturer, or (3) destroy the entire shipment. Based on microscopic identification, the culture analysis was positive for A. oryzae. This could not be confirmed by molecular techniques because of the genetic proximity of A. oryzae and A. flavus. Because A. flavus can produce aflatoxins, we tested for them using mass spectrometry. Aflatoxins B1, B2, G1, G2, and M1 were not detected; however, given the specifics of this situation, we could not discard the possibility of the presence of other aflatoxins, such as P1, B3, GM2, and ethoxyaflatoxin B2. We concluded that the contamination by A. oryzae was probably due to food products. However, because of the possible presence of aflatoxins, occupational health risks could not be entirely ruled out. The decision was therefore taken to destroy all the jewelry boxes by incineration. To avoid a similar situation we propose: (1) to maintain conditions limiting mold contamination during production (not eating on the work site, efficient ventilation systems); (2) to desiccate the products before sending them; and (3) to closely control the levels of dampness during storage and transport.

  17. Box-Cox transformation for QTL mapping.

    Science.gov (United States)

    Yang, Runqing; Yi, Nengjun; Xu, Shizhong

    2006-01-01

    The maximum likelihood method of QTL mapping assumes that the phenotypic values of a quantitative trait follow a normal distribution. If the assumption is violated, some forms of transformation should be taken to make the assumption approximately true. The Box-Cox transformation is a general transformation method which can be applied to many different types of data. The flexibility of the Box-Cox transformation is due to a variable, called transformation factor, appearing in the Box-Cox formula. We developed a maximum likelihood method that treats the transformation factor as an unknown parameter, which is estimated from the data simultaneously along with the QTL parameters. The method makes an objective choice of data transformation and thus can be applied to QTL analysis for many different types of data. Simulation studies show that (1) Box-Cox transformation can substantially increase the power of QTL detection; (2) Box-Cox transformation can replace some specialized transformation methods that are commonly used in QTL mapping; and (3) applying the Box-Cox transformation to data already normally distributed does not harm the result.

  18. Personality and Behavior in Social Dilemmas: Testing the Situational Strength Hypothesis and the Role of Hypothetical Versus Real Incentives.

    Science.gov (United States)

    Lozano, José H

    2016-02-01

    Previous research aimed at testing the situational strength hypothesis suffers from serious limitations regarding the conceptualization of strength. In order to overcome these limitations, the present study attempts to test the situational strength hypothesis based on the operationalization of strength as reinforcement contingencies. One dispositional factor of proven effect on cooperative behavior, social value orientation (SVO), was used as a predictor of behavior in four social dilemmas with varying degree of situational strength. The moderating role of incentive condition (hypothetical vs. real) on the relationship between SVO and behavior was also tested. One hundred undergraduates were presented with the four social dilemmas and the Social Value Orientation Scale. One-half of the sample played the social dilemmas using real incentives, whereas the other half used hypothetical incentives. Results supported the situational strength hypothesis in that no behavioral variability and no effect of SVO on behavior were found in the strongest situation. However, situational strength did not moderate the effect of SVO on behavior in situations where behavior showed variability. No moderating effect was found for incentive condition either. The implications of these results for personality theory and assessment are discussed. © 2014 Wiley Periodicals, Inc.

  19. Aluminum ''egg-box'' panel as an energy absorber for pedestrian protection

    Energy Technology Data Exchange (ETDEWEB)

    Nowpada, Sravanthi; Chirwa, Efford C.; Myler, Peter; Matsika, Emmanuel [Bolton Automotive and Aerospace Research Group (BAARG), School of Built Environment and Engineering, University of Bolton (United Kingdom)

    2010-07-15

    This paper evaluates the quasi-static performance of lightweight aluminum ''egg-box'' panels which have an improved architecture specifically designed to increase the energy absorption capability. In its entirety, the egg-box panel structure investigated herein is made up of arrays of positive and negative frusta. To understand the collapse mechanism and the factors influencing the energy absorption thereof, compressive tests were conducted under similar test conditions on two single frusta, one constrained in situ and the other separated from the egg-box panel exposing the free-free edges. Their load-displacement histories show characteristics that are similar, with a rise in load to a point where they plateau at a steady state load for the entire collapse time. But the energy absorbed by the in situ constrained frustum is 80% greater than that separated from the egg-box panel with free-free edges. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  20. Development of in-situ rock shear test under low compressive to tensile normal stress

    International Nuclear Information System (INIS)

    Nozaki, Takashi; Shin, Koichi

    2003-01-01

    The purpose of this study is to develop an in-situ rock shear testing method to evaluate the shear strength under low normal stress condition including tensile stress, which is usually ignored in the assessment of safety factor of the foundations for nuclear power plants against sliding. The results are as follows. (1) A new in-situ rock shear testing method is devised, in which tensile normal stress can be applied on the shear plane of a specimen by directly pulling up a steel box bonded to the specimen. By applying the counter shear load to cancel the moment induced by the main shear load, it can obtain shear strength under low normal stress. (2) Some model tests on Oya tuff and diatomaceous mudstone have been performed using the developed test method. The shear strength changed smoothly from low values at tensile normal stresses to higher values at compressive normal stresses. The failure criterion has been found to be bi-linear on the shear stress vs normal stress plane. (author)

  1. Predicting hand function in older adults: evaluations of grip strength, arm curl strength, and manual dexterity.

    Science.gov (United States)

    Liu, Chiung-Ju; Marie, Deana; Fredrick, Aaron; Bertram, Jessica; Utley, Kristen; Fess, Elaine Ewing

    2017-08-01

    Hand function is critical for independence in activities of daily living for older adults. The purpose of this study was to examine how grip strength, arm curl strength, and manual dexterous coordination contributed to time-based versus self-report assessment of hand function in community-dwelling older adults. Adults aged ≥60 years without low vision or neurological disorders were recruited. Purdue Pegboard Test, Jamar hand dynamometer, 30-second arm curl test, Jebsen-Taylor Hand Function Test, and the Late-Life Function and Disability Instrument were administered to assess manual dexterous coordination, grip strength, arm curl strength, time-based hand function, and self-report of hand function, respectively. Eighty-four adults (mean age = 72 years) completed the study. Hierarchical multiple regressions show that older adults with better arm curl strength (β = -.25, p function test. In comparison, older adults with better grip strength (β = .40, p function. The relationship between grip strength and hand function may be test-specific. Grip strength becomes a significant factor when the test requires grip strength to successfully complete the test tasks. Arm curl strength independently contributed to hand function in both time-based and self-report assessments, indicating that strength of extrinsic muscles of the hand are essential for hand function.

  2. The BOXES Methodology Black Box Dynamic Control

    CERN Document Server

    Russell, David W

    2012-01-01

    Robust control mechanisms customarily require knowledge of the system’s describing equations which may be of the high order differential type.  In order to produce these equations, mathematical models can often be derived and correlated with measured dynamic behavior.  There are two flaws in this approach one is the level of inexactness introduced by linearizations and the other when no model is apparent.  Several years ago a new genre of control systems came to light that are much less dependent on differential models such as fuzzy logic and genetic algorithms. Both of these soft computing solutions require quite considerable a priori system knowledge to create a control scheme and sometimes complicated training program before they can be implemented in a real world dynamic system. Michie and Chambers’ BOXES methodology created a black box system that was designed to control a mechanically unstable system with very little a priori system knowledge, linearization or approximation.  All the method need...

  3. Assessing Reactive Strength Measures in Jumping and Hopping Using the Optojump™ System

    Directory of Open Access Journals (Sweden)

    Healy Robin

    2016-12-01

    Full Text Available The aim of this study was to assess the concurrent validity of the Optojump™ system (Microgate, Bolzano, Italy versus a force platform in the estimation of temporal and reactive strength measures. In two separate investigations, twenty physically active males performed double-leg and single-leg drop jumps from a box height of 0.3 m and a 10 s vertical bilateral hopping test. Contact time, flight time and total time (the sum of contact and flight time were concurrently assessed during single and double-leg drop jumps and during hopping. Jump height, the reactive strength index and the reactive strength ratio were also calculated from contact time and flight time. Despite intraclass correlation coefficients (ICCs for all variables being close to 1 (ICC > 0.975, a significant overestimation was found in contact time (0.005 ± 0.002 s and underestimations in flight time (0.005 ± 0.003 s, the reactive strength index (0.04 ± 0.02 m·s-1 and the reactive strength ratio (0.07 ± 0.04. Overestimations in contact time and underestimations in flight time were attributed to the physical design of the Optojump™ system as the transmitter and receiver units were positioned 0.003 m above the floor level. The Optojump™ demonstrated excellent overall temporal validity with no differences found between systems for total time. Coaches are advised to be consistent with the instrumentation used to assess athletes, however, in the case of comparison between reactive strength values collected with the Optojump™ and values collected with a force platform, regression equations are provided.

  4. The heart rate response to nintendo wii boxing in young adults.

    Science.gov (United States)

    Bosch, Pamela R; Poloni, Joseph; Thornton, Andrew; Lynskey, James V

    2012-06-01

    To determine if 30 minutes of Nintendo Wii Sports boxing provides cardiorespiratory benefits and contributes to the daily exercise recommendations for healthy young adults. Twenty healthy 23- to 27-year-olds participated in two sessions to measure maximum heart rate (HR(max)) via a treadmill test and heart rate (HR) response to 30 minutes of Wii Sports boxing. Heart rate in beats per minute (bpm) was measured continuously, and exercise intensity during each minute of play was stratified as a percentage of HR(max). Mixed designs analysis of variance (ANOVA) and Pearson product moment correlations were used to analyze the data. Mean (SD) HR response to boxing was 143 (15) bpm or 77.5% (10.0%) of HR(max). The mean HR response for experienced participants was significantly lower than inexperienced participants, P = .007. The ANOVA revealed a significant interaction between experience and time spent at various intensities, P = .009. Experienced participants spent more time in light to vigorous intensities, inexperienced participants in moderate to very hard intensities. Fitness was not correlated with mean HR response to boxing, P = .49. Thirty minutes of Nintendo Wii Sports boxing provides a moderate to vigorous aerobic response in healthy young adults and can contribute to daily recommendations for physical activity.

  5. Effect of root canal rinsing protocol on dentin bond strength of two resin cements using three different method of test.

    Science.gov (United States)

    Khoroushi, Maryam; Sheikhi, Mohammadreza; Khalilian-Gourtani, Amirhossein; Soleimani, Bahram

    2016-07-01

    Different studies have used different tests to evaluate bond strength of resin cements to root dentin. In this in vitrostudy, three different tests were used to evaluate the bond strength of two resin cements to root dentin using two root dentin irrigation protocols. Ninety-six intact single-rooted teeth were selected for this study. Forty-eight teeth, with a root length of 15mm, were randomly divided into two groups and irrigated with normal saline or 2.5% sodium hypochlorite solutions during root canal preparation, respectively. For each 12 specimens from each group, fiber post #1 was bonded using an etch-and-rinse (Duo-Link) and a self-adhesive (BisCem) resin cement, respectively. After incubation, two specimens were prepared for the push-out test from the middle thirds of the roots. In another 24 teeth, after two 1.5-mm sections were prepared from the middle thirds of the prepared roots, sections of the post were bonded in two subgroups with each of the cements mentioned above and the samples were prepared for the pull-out test. For shear test, the crowns of 48 teeth were cut away, the dentin surfaces were prepared, the two irrigation solutions were used, and the resin cements were bonded. Data collected from the three tests were evaluated by ANOVA, post-hoc Tukey and Weibull tests (α=0.05). There were significant differences in the mean bond strength values between the three bond strength tests (Pstrength in all tests (P>0.05). Under the limitations of the present study, the method of the test used had an effect on the recorded bond strength between the resin cement and root dentin. Cement type and irrigation protocol resulted in similar variations with all the tests. Push-out and shear tests exhibited more coherent results. Bond strength, endodontically treated tooth, fiber post, resin cement, sodium hypochlorite.

  6. Green and early age compressive strength of extruded cement mortar monitored with compression tests and ultrasonic techniques

    International Nuclear Information System (INIS)

    Voigt, Thomas; Malonn, Tim; Shah, Surendra P.

    2006-01-01

    Knowledge about the early age compressive strength development of cementitious materials is an important factor for the progress and safety of many construction projects. This paper uses cylindrical mortar specimens produced with a ram extruder to investigate the transition of the mortar from plastic and deformable to hardened state. In addition, wave transmission and reflection measurements with P- and S-waves were conducted to obtain further information about the microstructural changes during the setting and hardening process. The experiments have shown that uniaxial compression tests conducted on extruded mortar cylinders are a useful tool to evaluate the green strength as well as the initiation and further development of the compressive strength of the tested material. The propagation of P-waves was found to be indicative of the internal structure of the tested mortars as influenced, for example, by the addition of fine clay particles. S-waves used in transmission and reflection mode proved to be sensitive to the inter-particle bonding caused by the cement hydration and expressed by an increase in compressive strength

  7. Glove boxes

    International Nuclear Information System (INIS)

    Eisert, G.A.

    1979-01-01

    An arrangement for effecting access for performing work within a glove box comprises an elongate arm-length impermeable flexible sleeve, a fitting having an aperture therethrough, adapted to be secured in sealing relation in a port, in a wall of the glove box, the fitting including an outwardly extending lip having at least one continuous groove extending around its outer periphery, one end of the sleeve extending through the aperture in fitting and being folded back against the outer periphery of the lip, a resilient fastening ring securing the sleeve in sealing engagement in the groove, clamping means securing the sleeves to the lip and a glove secured in sealing relation via a bushing to the other end of the sleeve. (author)

  8. Magnetorotational Dynamo Action in the Shearing Box

    Science.gov (United States)

    Walker, Justin; Boldyrev, Stanislav

    2017-10-01

    Magnetic dynamo action caused by the magnetorotational instability is studied in the shearing-box approximation with no imposed net magnetic flux. Consistent with recent studies, the dynamo action is found to be sensitive to the aspect ratio of the box: it is much easier to obtain in tall boxes (stretched in the direction normal to the disk plane) than in long boxes (stretched in the radial direction). Our direct numerical simulations indicate that the dynamo is possible in both cases, given a large enough magnetic Reynolds number. To explain the relatively larger effort required to obtain the dynamo action in a long box, we propose that the turbulent eddies caused by the instability most efficiently fold and mix the magnetic field lines in the radial direction. As a result, in the long box the scale of the generated strong azimuthal (stream-wise directed) magnetic field is always comparable to the scale of the turbulent eddies. In contrast, in the tall box the azimuthal magnetic flux spreads in the vertical direction over a distance exceeding the scale of the turbulent eddies. As a result, different vertical sections of the tall box are permeated by large-scale nonzero azimuthal magnetic fluxes, facilitating the instability. NSF AGS-1261659, Vilas Associates Award, NSF-Teragrid Project TG-PHY110016.

  9. COMPARISON BETWEEN TEST METHODS TO DETERMINE WOOD EMBEDMENT STRENGTH PARALLEL TO THE GRAIN

    Directory of Open Access Journals (Sweden)

    Diego Henrique de Almeida

    Full Text Available ABSTRACT This study compares the test methods according to the ABNT NBR 7190:1997, EN 383:2007, ASTM D5764:2007, EUROCODE 5:2004, NDS:2001 standards in order to provide support to establish a new test method for determining the embedment strength of wood parallel to the grain. Parallel-to-grain tests were carried out for six wood species (Schizolobium amazonicum; Pinus elliottii; Pinus oocarpa; Hymenaea spp.; Lyptus(r: hybrid Eucalyptus grandis and Eucalyptus urophylla, and Goupia glabra using four diameters (8 mm, 10 mm, 12 mm and 16 mm for the metal pin fasteners (bolts. The experimental results obtained according to the EN 383:2007 standard were closer to the specific values for the metal-dowel connections design used by ABNT NBR 7190:1997, which are considered equal compression parallel to the grain. The use of maximum embedment force or the force causing displacement of 5 mm between the bolt and the test-piece as criteria for determining embedment strength for EN 383:2007 appears to be more appropriate than the criteria used by the Brazilian and American Standards.

  10. Opportunities in white-box cryptography

    NARCIS (Netherlands)

    Michiels, W.

    White-box cryptography is the discipline of implementing a cryptographic algorithm in software such that an adversary will have difficulty extracting the cryptographic key. This approach assumes that the adversary has full access to and full control over the implementation's execution. White-box

  11. Strength and leak testing of plasma activated bonded interfaces

    DEFF Research Database (Denmark)

    Visser, M.M.; Weichel, Steen; Reus, Roger De

    2002-01-01

    on detection of changes in membrane deflections. The detection limit for leak was 8E-13 mbar l/s. For comparison, strength and leak tests were also performed with regular fusion bonded wafers annealed at 1100 degreesC. The PAB was found to withstand post-processing steps such as RCA cleaning, 24 h in de......-ionised water (DIW), 24 h in 2.5% HF, 24 h in acetone and 60 s in a resist developer. By analysing the thin silicon oxide present on the surfaces to be bonded with optical methods, the influence of pre-cleaning and activation process parameters was investigated....

  12. Evaluation of in-place concrete strength by core testing.

    Science.gov (United States)

    2016-11-01

    The overall objective of the work contained in this report is to develop an ALDOT procedure to evaluate core strength results obtained under various conditions. Since there are many factors that influence the apparent strength of cores, strength corr...

  13. GLASS BOX

    National Research Council Canada - National Science Library

    Curtis, Laura

    2008-01-01

    The goals of this effort were to develop Glass Box capabilities to allow for the capturing of analyst activities and the associated data resources, track and log the results of automated processing...

  14. The lithium vapor box divertor

    International Nuclear Information System (INIS)

    Goldston, R J; Schwartz, J; Myers, R

    2016-01-01

    It has long been recognized that volumetric dissipation of the plasma heat flux from a fusion power system is preferable to its localized impingement on a material surface. Volumetric dissipation mitigates both the anticipated very high heat flux and intense particle-induced damage due to sputtering. Recent projections to a tokamak demonstration power plant suggest an immense upstream parallel heat flux, of order 20 GW m −2 , implying that fully detached operation may be a requirement for the success of fusion power. Building on pioneering work on the use of lithium by Nagayama et al and by Ono et al as well as earlier work on the gas box divertor by Watkins and Rebut, we present here a concept for a lithium vapor box divertor, in which lithium vapor extracts momentum and energy from a fusion-power-plant divertor plasma, using fully volumetric processes. At the high powers and pressures that are projected this requires a high density of lithium vapor, which must be isolated from the main plasma in order to avoid lithium build-up on the chamber walls or in the plasma. Isolation is achieved through a powerful multi-box differential pumping scheme available only for condensable vapors. The preliminary box-wise calculations are encouraging, but much more work is required to demonstrate the practical viability of this scheme, taking into account at least 2D plasma and vapor flows within and between the vapor boxes and out of the vapor boxes to the main plasma. (paper)

  15. Policy statement—Boxing participation by children and adolescents.

    Science.gov (United States)

    Purcell, Laura; LeBlanc, Claire M A

    2011-09-01

    Thousands of boys and girls younger than 19 years participate in boxing in North America. Although boxing provides benefits for participants, including exercise, self-discipline, and self-confidence, the sport of boxing encourages and rewards deliberate blows to the head and face. Participants in boxing are at risk of head, face, and neck injuries, including chronic and even fatal neurologic injuries. Concussions are one of the most common injuries that occur with boxing. Because of the risk of head and facial injuries, the American Academy of Pediatrics and the Canadian Paediatric Society oppose boxing as a sport for children and adolescents. These organizations recommend that physicians vigorously oppose boxing in youth and encourage patients to participate in alternative sports in which intentional head blows are not central to the sport.

  16. Spirit Boxes: Expressions of Culture.

    Science.gov (United States)

    DeMuro, Ted

    1984-01-01

    After studying the culture and art of the ancient civilizations of South America, Mesopotamia, Greece, and Egypt, secondary level art students made spirit boxes as expressions of the various cultures. How to make the boxes and how to prepare the face molds are described. (RM)

  17. Reflector dowel strength test, Fort St. Vrain

    International Nuclear Information System (INIS)

    Doll, D.W.

    1975-01-01

    The strength of the 44.45 mm (1.75 in.) diameter Fort St. Vrain (FSV) reflector dowel for loads directed radially inward toward the center of the element was measured. For a statically applied load, the strength exceeded 5783 N (1300 lb) in direct shear. This strength remained after load cycling 100 times to 4448 N (1000 lb), 10 times to 4893 N (1100 lb), 10 times to 5338 N (1200 lb), and two times to 5783 N (1300 lb). Typically, the deflection to ultimate failure was approximately 1.0 mm (0.04 in.). At about 3316 N (750 lb) and 0.20 mm (0.008 in.) deflection, one of the webs between the dowel and a coolant hole cracked, apparently redistributing the load. No further failure occurred up to the ultimate load of 5783+ N (1300+ lb)

  18. X-Ray Microtomography (μCT as a Useful Tool for Visualization and Interpretation of Shear Strength Test Results

    Directory of Open Access Journals (Sweden)

    Stefaniuk Damian

    2015-02-01

    Full Text Available The paper demonstrates the applicability of X-ray microtomography (ìCT to analysis of the results of shear strength examinations of clayey soils. The method of X-ray three-dimensional imaging offers new possibilities in soil testing. The work focuses on a non-destructive method of evaluation of specimen quality used in shear tests and mechanical behavior of soil. The paper presents the results of examination of 4 selected clayey soils. Specimens prepared for the triaxial test have been scanned using ìCT before and after the triaxial compression tests. The shear strength parameters of the soils have been estimated. Changes in soil structure caused by compression and shear failure have been presented as visualizations of the samples tested. This allowed for improved interpretation and evaluation of soil strength parameters and recognition of pre-existing fissures and the exact mode of failure. Basic geometrical parameters have been determined for selected cross-sections of specimens after failure. The test results indicate the utility of the method applied in soil testing.

  19. Test-Retest Reliability of Isokinetic Knee Strength Measurements in Children Aged 8 to 10 Years.

    Science.gov (United States)

    Fagher, Kristina; Fritzson, Annelie; Drake, Anna Maria

    Isokinetic dynamometry is a useful tool to objectively assess muscle strength of children and adults in athletic and rehabilitative settings. This study examined test-retest reliability of isokinetic knee strength measurements in children aged 8 to 10 years and defined limits for the minimum difference (MD) in strength that indicates a clinically important change. Isokinetic knee strength measurements (using the Biodex System 4) in children will provide reliable results. Descriptive laboratory study. In 22 healthy children, 5 maximal concentric (CON) knee extensor (KE) and knee flexor (KF) contractions at 2 angular velocities (60 deg/s and 180 deg/s) and 5 maximal eccentric (ECC) KE/KF contractions at 60 deg/s were assessed 7 days apart. The intraclass correlation coefficient (ICC 2.1 ) was used to examine relative reliability, and the MD was calculated on the basis of standard error of measurement. ICCs for CON KE/KF peak torque measurements were fair to excellent (range, 0.49-0.81). The MD% values for CON KE and KF ranged from 31% to 37% at 60 deg/s and from 34% to 39% at 180 deg/s. ICCs in the ECC mode were good (range, 0.60-0.70), but associated MD% values were high (>50%). There was no systematic error for CON KE/KF and ECC KE strength measurements at 60 deg/s, but systematic error was found for all other measurements. The dynamometer provides a reliable analysis of isokinetic CON knee strength measurements at 60 deg/s in children aged 8 to 10 years. Measurements at 180 deg/s and in the ECC mode were not reliable, indicating a need for more familiarization prior to testing. The MD values may help clinicians to determine whether a change in knee strength is due to error or intervention.

  20. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    Science.gov (United States)

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair

  1. Grey-Box Modelling of Pharmacokinetic /Pharmacodynamic Systems

    DEFF Research Database (Denmark)

    Tornøe, Christoffer Wenzel; Jacobsen, Judith L.; Pedersen, Oluf

    2004-01-01

    Grey-box pharmacokinetic/pharmacodynamic (PK/PD) modelling is presented as a promising way of modelling PK/PD systems. The concept behind grey-box modelling is based on combining physiological knowledge along with information from data in the estimation of model parameters. Grey-box modelling...

  2. Packing a cake into a box

    KAUST Repository

    Skopenkov, Mikhail

    2011-01-01

    Given a triangular cake and a box in the shape of its mirror image, how can the cake be cut into a minimal number of pieces so that it can be put into the box? The cake has icing, so we are not allowed to put it into the box upside down. V. G. Boltyansky asked this question in 1977 and showed that three pieces always suffice. In this paper we provide examples of cakes that cannot be cut into two pieces to be put into the box. This shows that three is the answer to Boltyansky's question. We also give examples of cakes which can be cut into two pieces. © THE MATHEMATICAL ASSOCIATION OF AMERICA.

  3. Packing a cake into a box

    KAUST Repository

    Skopenkov, Mikhail

    2011-05-01

    Given a triangular cake and a box in the shape of its mirror image, how can the cake be cut into a minimal number of pieces so that it can be put into the box? The cake has icing, so we are not allowed to put it into the box upside down. V. G. Boltyansky asked this question in 1977 and showed that three pieces always suffice. In this paper we provide examples of cakes that cannot be cut into two pieces to be put into the box. This shows that three is the answer to Boltyansky\\'s question. We also give examples of cakes which can be cut into two pieces. © THE MATHEMATICAL ASSOCIATION OF AMERICA.

  4. Strength assessment of a cryostat used by the hollow electron test station.

    CERN Document Server

    Efremov, Filip

    2015-01-01

    The following report explains the work I have done on my summer student work project and the experience I have gained during the process. The work consisted of a strength assessment of a cryogenic vacuum insulated vessel according to European regulations. The cryogenic vacuum insulated vessel is used for the cooling of the solenoids. The solenoids are used in the hollow electron test station and create the magnetic fields used for testing electron guns and validating the concept of a hollow electron lens.

  5. The future of grey-box fuzzing

    OpenAIRE

    Hjelt, Isak

    2017-01-01

    Society are becoming more dependent on software, and more artifacts are being connected to the Internet each day [31]. This makes the work of tracking down vulnerabilities in software a moral obligation for software developers. Since manual testing is expensive [7], automated bug finding techniques are attractive within the quality assurance field, since it can save companies a lot of money. This thesis summarizes the research of an automated bug finding technique called grey-box fuzzing, wit...

  6. Residual-strength tests of L-1011 vertical fin components after 10 and 20 years of simulated flight service

    Science.gov (United States)

    Lopez, O. F.

    1984-01-01

    Part of the NASA/ACEE Program was to determine the effect of long-term durability testing on the residual strength of graphite-epoxy cover panel and spar components of the Lockheed L-1011 aircraft vertical stabilizer. The results of these residual strength tests are presented herein. The structural behavior and failure mode of both cover panel and spar components were addressed, and the test results obtained were compared with the static test results generated by Lockheed. The effect of damage on one of the spar specimens was described.

  7. Ion-wake Field inside a Glass Box

    OpenAIRE

    Chen, Mudi; Dropmann, Michael; Zhang, Bo; Matthews, Lorin S.; Hyde, Truell W.

    2016-01-01

    The confinement provided by a glass box is proving ideal for the formation of vertically aligned structures and a convenient method for controlling the number of dust particles comprising these dust structures, as well as their size and shape. In this paper, the electronic confinement of the glass box is mapped and the particle interactions between the particle pairs inside the glass box are measured. The ion-wake field is shown to exist within the glass box and its vertical and horizontal ex...

  8. Reliability and validity of a low load endurance strength test for upper and lower extremities in patients with fibromyalgia.

    Science.gov (United States)

    Munguía-Izquierdo, Diego; Legaz-Arrese, Alejandro

    2012-11-01

    To evaluate the reliability, standard error of the mean (SEM), clinical significant change, and known group validity of 2 assessments of endurance strength to low loads in patients with fibromyalgia syndrome (FS). Cross-sectional reliability and comparative study. University Pablo de Olavide, Seville, Spain. Middle-aged women with FS (n=95) and healthy women (n=64) matched for age, weight, and body mass index (BMI) were recruited for the study. Not applicable. The endurance strength to low loads tests of the upper and lower extremities and anthropometric measures (BMI) were used for the evaluations. The differences between the readings (tests 1 and 2) and the SDs of the differences, intraclass correlation coefficient (ICC) model (2,1), 95% confidence interval for the ICC, coefficient of repeatability, intrapatient SD, SEM, Wilcoxon signed-rank test, and Bland-Altman plots were used to examine reliability. A Mann-Whitney U test was used to analyze the differences in test values between the patient group and the control group. We hypothesized that patients with FS would have an endurance strength to low loads performance in lower and upper extremities at least twice as low as that of the healthy controls. Satisfactory test-retest reliability and SEMs were found for the lower extremity, dominant arm, and nondominant arm tests (ICC=.973-.979; P.05 for all). The Bland-Altman plots showed 95% limits of agreement for the lower extremity (4.7 to -4.5), dominant arm (3.8 to -4.4), and nondominant arm (3.9 to -4.1) tests. The endurance strength to low loads test scores for the patients with FS were 4-fold lower than for the controls in all performed tests (P<.001 for all). The endurance strength to low loads tests showed good reliability and known group validity and can be recommended for evaluating endurance strength to low loads in patients with FS. For individual evaluation, however, an improved score of at least 4 and 5 repetitions for the upper and lower extremities

  9. TOUGHREACT Testing in High Ionic Strength Brine Sandstone Systems

    International Nuclear Information System (INIS)

    Xu, Tianfu

    2008-01-01

    Deep saline formations and oil and gas reservoirs often contain concentrated brine solutions of ionic strength greater than 1 (I > 1 M). Geochemical modeling, involving high ionic strength brines, is a challenge. In the original TOUGHREACT code (Xu et al., 2004; Xu et al., 2006), activity coefficients of charged aqueous species are computed using an extended Debye-Huckel (DH) equation and parameters derived by Helgeson et al. (1981). The DH model can deal with ionic strengths from dilute to moderately saline water (up to 6 molal for an NaCl-dominant solution). The equations implemented for the DH model are presented in Appendix A. During the course of the Yucca Mountain project, a Pitzer ion-interaction model was implemented into TOUGHREACT. This allows the application of this simulator to problems involving much more concentrated aqueous solutions, such as those involving geochemical processes in and around high-level nuclear waste repositories where fluid evaporation and/or boiling is expected to occur (Zhang et al., 2007). The Pitzer ion-interaction model, which we refer to as the Pitzer virial approach, and associated ion-interaction parameters have been applied successfully to study non-ideal concentrated aqueous solutions. The formulation of the Pitzer model is presented in Appendix B; detailed information can be founded in Zhang et al. (2007). For CO 2 geological sequestration, the Pitzer ion-interaction model for highly concentrated brines was incorporated into TOUGHREACT/ECO2N, then was tested and compared with a previously implemented extended Debye-Hueckel (DH) ion activity model. The comparison was made through a batch geochemical system using a Gulf Coast sandstone saline formation

  10. Water-cooled target-box design at LAMPF

    International Nuclear Information System (INIS)

    Grisham, D.; Lambert, J.

    1983-01-01

    The target boxes in the main experimental beam line (Line A) at the Clinton P. Anderson Meson Physics Facility (LAMPF) have operated since 1976. A program of replacing the boxes is underway. This paper will present past history, design considerations, calculational results and the final box design

  11. CSF-biomarkers in Olympic boxing: diagnosis and effects of repetitive head trauma.

    Directory of Open Access Journals (Sweden)

    Sanna Neselius

    Full Text Available BACKGROUND: Sports-related head trauma is common but still there is no established laboratory test used in the diagnostics of minimal or mild traumatic brain injuries. Further the effects of recurrent head trauma on brain injury markers are unknown. The purpose of this study was to investigate the relationship between Olympic (amateur boxing and cerebrospinal fluid (CSF brain injury biomarkers. METHODS: The study was designed as a prospective cohort study. Thirty Olympic boxers with a minimum of 45 bouts and 25 non-boxing matched controls were included in the study. CSF samples were collected by lumbar puncture 1-6 days after a bout and after a rest period for at least 14 days. The controls were tested once. Biomarkers for acute and chronic brain injury were analysed. RESULTS: NFL (mean ± SD, 532±553 vs 135±51 ng/L p = 0.001, GFAP (496±238 vs 247±147 ng/L p80% of the boxers demonstrate that both the acute and the cumulative effect of head trauma in Olympic boxing may induce CSF biomarker changes that suggest minor central nervous injuries. The lack of normalization of NFL and GFAP after the rest period in a subgroup of boxers may indicate ongoing degeneration. The recurrent head trauma in boxing may be associated with increased risk of chronic traumatic brain injury.

  12. Relationship between thin-film bond strength as measured by a scratch test, and indentation hardness for bonding agents.

    Science.gov (United States)

    Kusakabe, Shusuke; Rawls, H Ralph; Hotta, Masato

    2016-03-01

    To evaluate thin-film bond strength between a bonding agent and human dentin, using a scratch test, and the characteristics and accuracy of measurement. One-step bonding agents (BeautiBond; Bond Force; Adper Easy Bond; Clearfil tri-S Bond) and two-step bonding agents (Cleafil SE Bond; FL-Bond II) were investigated in this study. Flat dentin surfaces were prepared for extracted human molars. The dentin surfaces were ground and bonding agents were applied and light cured. The thin-film bond strength test of the specimens was evaluated by the critical load at which the coated bonding agent failed and dentin appeared. The scratch mark sections were then observed under a scanning electron microscope. Indentation hardness was evaluated by the variation in depth under an applied load of 10gf. Data were compared by one-way ANOVA with the Scheffé's post hoc multiple comparison test (pstrength and indentation hardness were analyzed using analysis of correlation and covariance. The thin-film bond strength of two-step bonding agents were found to be significantly higher than that of one-step bonding agents with small standard deviations. Scratch marks consistently showed adhesive failure in the vicinity of the bonding agent/dentin interface. The indentation hardness showed a trend that two-step bonding agents have greater hardness than one-step bonding agents. A moderately significant correlation (r(2)=0.31) was found between thin-film bond strength and indentation hardness. Thin-film bond strength test is a valid and reliable means of evaluating bond strength in the vicinity of the adhesive interface and is more accurate than other methods currently in use. Further, the thin-film bond strength is influenced by the hardness of the cued bonding agent. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  13. Construction of dry-boxes for plutonium metallurgy

    International Nuclear Information System (INIS)

    Grison, E.; Pascard, R.

    1958-01-01

    The dry-boxes used at Chatillon are of two main types: a) boxes with a metal frame work of welded angle-pieces, panels of plexiglass, bakelite, duralumin, etc... They include a standard panel which enables them to be connected up to the contaminated repairs workshop; b) boxes made entirely of welded plastic. The working face only is of plexiglas held by screw clamps to a pure rubber joint. These boxes, which cannot be connected to the contaminated workshop, are generally reserved for small pieces of chemical apparatus. None has yet been used for working under argon, although their airtightness is excellent. After an interval of several hours, in fact, no decrease in the pressure inside the box can be detected. Several means can be adopted to ensure that the joints between panels and mountings are absolutely air-tight. Up to the present we are using three types of box with metal framework at the same time, without being able to make a definitive choice. (author) [fr

  14. Six-minute walk test and respiratory muscle strength in patients with uncontrolled severe asthma: a pilot study.

    Science.gov (United States)

    Pereira, Luiz Fernando Ferreira; Mancuzo, Eliane Viana; Rezende, Camila Farnese; Côrrea, Ricardo de Amorim

    2015-01-01

    To evaluate respiratory muscle strength and six-minute walk test (6MWT) variables in patients with uncontrolled severe asthma (UCSA). This was a cross-sectional study involving UCSA patients followed at a university hospital. The patients underwent 6MWT, spirometry, and measurements of respiratory muscle strength, as well as completing the Asthma Control Test (ACT). The Mann-Whitney test was used in order to analyze 6MWT variables, whereas the Kruskal-Wallis test was used to determine whether there was an association between the use of oral corticosteroids and respiratory muscle strength. We included 25 patients. Mean FEV1 was 58.8 ± 21.8% of predicted, and mean ACT score was 14.0 ± 3.9 points. No significant difference was found between the median six-minute walk distance recorded for the UCSA patients and that predicted for healthy Brazilians (512 m and 534 m, respectively; p = 0.14). During the 6MWT, there was no significant drop in SpO2. Mean MIP and MEP were normal (72.9 ± 15.2% and 67.6 ± 22.2%, respectively). Comparing the patients treated with at least four courses of oral corticosteroids per year and those treated with three or fewer, we found no significant differences in MIP (p = 0.15) or MEP (p = 0.45). Our findings suggest that UCSA patients are similar to normal subjects in terms of 6MWT variables and respiratory muscle strength. The use of oral corticosteroids has no apparent impact on respiratory muscle strength.

  15. 49 CFR 178.515 - Standards for reconstituted wood boxes.

    Science.gov (United States)

    2010-10-01

    ... wood boxes. (a) The identification code for a reconstituted wood box is 4F. (b) Construction requirements for reconstituted wood boxes are as follows: (1) The walls of boxes must be made of water... 49 Transportation 2 2010-10-01 2010-10-01 false Standards for reconstituted wood boxes. 178.515...

  16. Ocular complications of boxing

    Science.gov (United States)

    Bianco, M; Vaiano, A; Colella, F; Coccimiglio, F; Moscetti, M; Palmieri, V; Focosi, F; Zeppilli, P; Vinger, P

    2005-01-01

    Objectives: To investigate the prevalence of ocular injuries in a large population of boxers over a period of 16 years, in particular, the most severe lesions that may be vision threatening. Methods: Clinical records of the medical archive of the Italian Boxing Federation were analysed. A total of 1032 boxers were examined from February 1982 to October 1998. A complete ophthalmological history was available for 956, who formed the study population (a total of 10 697 examinations). The following data were collected: age when started boxing; duration of competitive boxing career (from the date of the first bout); weight category; a thorough ocular history. The following investigations were carried out: measurement of visual acuity and visual fields, anterior segment inspection, applanation tonometry, gonioscopy, and examination of ocular fundus. Eighty age matched healthy subjects, who had never boxed, formed the control group. Results: Of the 956 boxers examined, 428 were amateur (44.8%) and 528 professional (55.2%). The median age at first examination was 23.1 (4.3) years (range 15–36). The prevalence of conjunctival, corneal, lenticular, vitreal, ocular papilla, and retinal alterations in the study population was 40.9% compared with 3.1% in the control group (p⩽0.0001). The prevalence of serious ocular findings (angle, lens, macula, and peripheral retina alterations) was 5.6% in boxers and 3.1% in controls (NS). Conclusions: Boxing does not result in a higher prevalence of severe ocular lesions than in the general population. However, the prevalence of milder lesions (in particular with regard to the conjunctiva and cornea) is noteworthy, justifying the need for adequate ophthalmological surveillance. PMID:15665199

  17. 49 CFR 178.517 - Standards for plastic boxes.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Standards for plastic boxes. 178.517 Section 178... PACKAGINGS Non-bulk Performance-Oriented Packaging Standards § 178.517 Standards for plastic boxes. (a) The following are identification codes for plastic boxes: (1) 4H1 for an expanded plastic box; and (2) 4H2 for a...

  18. Reliability of using nondestructive tests to estimate compressive strength of building stones and bricks

    Directory of Open Access Journals (Sweden)

    Ali Abd Elhakam Aliabdo

    2012-09-01

    Full Text Available This study aims to investigate the relationships between Schmidt hardness rebound number (RN and ultrasonic pulse velocity (UPV versus compressive strength (fc of stones and bricks. Four types of rocks (marble, pink lime stone, white lime stone and basalt and two types of burned bricks and lime-sand bricks were studied. Linear and non-linear models were proposed. High correlations were found between RN and UPV versus compressive strength. Validation of proposed models was assessed using other specimens for each material. Linear models for each material showed good correlations than non-linear models. General model between RN and compressive strength of tested stones and bricks showed a high correlation with regression coefficient R2 value of 0.94. Estimation of compressive strength for the studied stones and bricks using their rebound number and ultrasonic pulse velocity in a combined method was generally more reliable than using rebound number or ultrasonic pulse velocity only.

  19. Nonneurologic emergencies in boxing.

    Science.gov (United States)

    Coletta, Domenic F

    2009-10-01

    Professional boxing has done an admirable job in promoting safety standards in its particular sport. However, injuries occur during the normal course of competition and, unfortunately, an occasional life-threatening emergency may arise. Although most common medical emergencies in boxing are injuries from closed head trauma, in this article those infrequent but potentially catastrophic nonneurologic conditions are reviewed along with some less serious emergencies that the physician must be prepared to address.

  20. Investigation of test methods for measuring compressive strength and modulus of two-dimensional carbon-carbon composites

    Science.gov (United States)

    Ohlhorst, Craig W.; Sawyer, James Wayne; Yamaki, Y. Robert

    1989-01-01

    An experimental evaluation has been conducted to ascertain the the usefulness of two techniques for measuring in-plane compressive failure strength and modulus in coated and uncoated carbon-carbon composites. The techniques involved testing specimens with potted ends as well as testing them in a novel clamping fixture; specimen shape, length, gage width, and thickness were the test parameters investigated for both coated and uncoated 0/90 deg and +/-45 deg laminates. It is found that specimen shape does not have a significant effect on the measured compressive properties. The potting of specimen ends results in slightly higher measured compressive strengths than those obtained with the new clamping fixture. Comparable modulus values are obtained by both techniques.

  1. BNL NONLINEAR PRE TEST SEISMIC ANALYSIS FOR THE NUPEC ULTIMATE STRENGTH PIPING TEST PROGRAM

    International Nuclear Information System (INIS)

    DEGRASSI, G.; HOFMAYER, C.; MURPHY, C.; SUZUKI, K.; NAMITA, Y.

    2003-01-01

    The Nuclear Power Engineering Corporation (NUPEC) of Japan has been conducting a multi-year research program to investigate the behavior of nuclear power plant piping systems under large seismic loads. The objectives of the program are: to develop a better understanding of the elasto-plastic response and ultimate strength of nuclear piping; to ascertain the seismic safety margin of current piping design codes; and to assess new piping code allowable stress rules. Under this program, NUPEC has performed a large-scale seismic proving test of a representative nuclear power plant piping system. In support of the proving test, a series of materials tests, static and dynamic piping component tests, and seismic tests of simplified piping systems have also been performed. As part of collaborative efforts between the United States and Japan on seismic issues, the US Nuclear Regulatory Commission (USNRC) and its contractor, the Brookhaven National Laboratory (BNL), are participating in this research program by performing pre-test and post-test analyses, and by evaluating the significance of the program results with regard to safety margins. This paper describes BNL's pre-test analysis to predict the elasto-plastic response for one of NUPEC's simplified piping system seismic tests. The capability to simulate the anticipated ratcheting response of the system was of particular interest. Analyses were performed using classical bilinear and multilinear kinematic hardening models as well as a nonlinear kinematic hardening model. Comparisons of analysis results for each plasticity model against test results for a static cycling elbow component test and for a simplified piping system seismic test are presented in the paper

  2. Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

    Science.gov (United States)

    Wollin, Martin; Purdam, Craig; Drew, Michael K

    2016-01-01

    To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  3. Glove boxes. Dimensions and requirements. Draft

    International Nuclear Information System (INIS)

    1985-07-01

    The standard is to be applied to work done in glove-boxes, whereby either the personnel need to be protected from the damaging effects of the materials being handled, or the materials from the effects of the environment. It is to be applied to glove-boxes in which substances are handled which emit ionising radiation (radioactive substances). This norm is not restricted to glove-boxes in which processes are carried out on a technique scale. In accordance with this norm, only those pressures and temperatures are allowed to be present in the glove-boxes, that do not offer significantly from the work areas. Alongside the stipulations of this standard regard is also always to be taken of the regulations in the radiation protection ordinance. (orig./HP) [de

  4. Comparison between two motor tests used for muscular strength/endurance analysis

    Directory of Open Access Journals (Sweden)

    Matheus Amarante do Nascimento

    2013-04-01

    Full Text Available The aim of this study was to compare motor performance in modified pull-up (MPUand flexed knee push-up (FKPU tests in young women. Thirty-five apparently healthy women (20.1±2.2 years were submitted to each one of the tests at an interval of48 hours in a random balanced design. Most individuals performed between 0 an d 10 repetitions (86% of the MPU test, and approximately 17% did not perform even one repetitions. On the other hand, the highest prevalence of outcomes for the FKPUtest was between 16 and 35 repetitions (71%. The Wilcoxon test identified statistically significant differences (p MPU. A moderate agreement (kappa =0.40 was found between the performance in both tests. Negative correlations of low magnitude (r=-0.23 to 0.46 were found between morphological variables (body weight,height, fat mass, and lean body mass and motor performance in both tests. The results suggest that the FKPU test is presented as a better indicator ofmuscular endurance levels, where as the MPU test seems to better discriminate muscular strength in young women.

  5. Effects of Strength of Accent on an L2 Interactive Lecture Listening Comprehension Test

    Science.gov (United States)

    Ockey, Gary J.; Papageorgiou, Spiros; French, Robert

    2016-01-01

    This article reports on a study which aimed to determine the effect of strength of accent on listening comprehension of interactive lectures. Test takers (N = 21,726) listened to an interactive lecture given by one of nine speakers and responded to six comprehension items. The test taker responses were analyzed with the Rasch computer program…

  6. Capitalized design of smart medicine box for elderly person based on quality function deployment (QFD)

    Science.gov (United States)

    Lestari, Brina Cindy; Dewi, Dyah Santhi; Widodo, Rusminto Tjatur

    2017-11-01

    The elderly who has a particular disease need to take some medicines in everyday with correct dosages and appropriate by time schedules. However, the elderly frequently forget to take medicines because of their memory weakened. Consequently, the product innovation of elderly healthcare is required for helping elderly takes some medicine more easily. This research aims to develop a smart medicine box by applying quality function deployment method. The first step is identifying elderly requirements through an ethnographic approach by interviewing thirty-two of elderly people as respondents. Then, the second step is translated elderly requirements to technical parameter for designing a smart medicine box. The smart box design is focused on two main requirements which have highest importance rating including alarm reminder for taking medicine and automatic medicine box. Finally, the prototype design has been created and tested by using usability method. The result shown that 90% from ten respondents have positive respond on the feature of smart medicine box. The voice of alarm reminder smart medicine box is easy to understand by elderly people for taking medicines.

  7. Introduction to the Box Particle Filtering

    OpenAIRE

    Gning, Amadou; Ristic, B; Mihaylova, Lyudmila; Abdallah, F.

    2013-01-01

    This paper presents a novel method for solving nonlinear filtering problems. This approach is particularly appealing in practical situations involving imprecise stochastic measurements, thus resulting in very broad posterior densities. It relies on the concept of a box particle, which occupies a small and controllable rectangular region having a non-zero volume in the state space. Key advantages of the box particle filter (Box-PF) against the standard particle filter (PF) are in its reduced c...

  8. Gold sales forecasting: The Box-Jenkins methodology

    Directory of Open Access Journals (Sweden)

    Johannes Tshepiso Tsoku

    2017-02-01

    Full Text Available The study employs the Box-Jenkins Methodology to forecast South African gold sales. For a resource economy like South Africa where metals and minerals account for a high proportion of GDP and export earnings, the decline in gold sales is very disturbing. Box-Jenkins time series technique was used to perform time series analysis of monthly gold sales for the period January 2000 to June 2013 with the following steps: model identification, model estimation, diagnostic checking and forecasting. Furthermore, the prediction accuracy is tested using mean absolute percentage error (MAPE. From the analysis, a seasonal ARIMA(4,1,4×(0,1,112 was found to be the “best fit model” with an MAPE value of 11% indicating that the model is fit to be used to predict or forecast future gold sales for South Africa. In addition, the forecast values show that there will be a decrease in the overall gold sales for the first six months of 2014. It is hoped that the study will help the public and private sectors to understand the gold sales or output scenario and later plan the gold mining activities in South Africa. Furthermore, it is hoped that this research paper has demonstrated the significance of Box-Jenkins technique for this area of research and that they will be applied in the future.

  9. Solar Anomalous and Magnetospheric Particle Explorer attitude control electronics box design and performance

    Science.gov (United States)

    Chamberlin, K.; Clagett, C.; Correll, T.; Gruner, T.; Quinn, T.; Shiflett, L.; Schnurr, R.; Wennersten, M.; Frederick, M.; Fox, S. M.

    1993-01-01

    The attitude Control Electronics (ACE) Box is the center of the Attitude Control Subsystem (ACS) for the Solar Anomalous and Magnetospheric Particle Explorer (SAMPEX) satellite. This unit is the single point interface for all of the Attitude Control Subsystem (ACS) related sensors and actuators. Commands and telemetry between the SAMPEX flight computer and the ACE Box are routed via a MIL-STD-1773 bus interface, through the use of an 80C85 processor. The ACE Box consists of the flowing electronic elements: power supply, momentum wheel driver, electromagnet driver, coarse sun sensor interface, digital sun sensor interface, magnetometer interface, and satellite computer interface. In addition, the ACE Box also contains an independent Safehold electronics package capable of keeping the satellite pitch axis pointing towards the sun. The ACE Box has dimensions of 24 x 31 x 8 cm, a mass of 4.3 kg, and an average power consumption of 10.5 W. This set of electronics was completely designed, developed, integrated, and tested by personnel at NASA GSFC. SAMPEX was launched on July 3, 1992, and the initial attitude acquisition was successfully accomplished via the analog Safehold electronics in the ACE Box. This acquisition scenario removed the excess body rates via magnetic control and precessed the satellite pitch axis to within 10 deg of the sun line. The performance of the SAMPEX ACS in general and the ACE Box in particular has been quite satisfactory.

  10. Influence of dimension box differences and time differences during operations of red box for motorcycles at signalized intersection

    Science.gov (United States)

    Mulyadi, Agah Muhammad

    2017-11-01

    Performance of signalized intersection has declined due to a large number of motorcycles. The number of motorcycles reached 98.2 million units and the composition of motorcycles has reached around 81.7% of the total composition of vehicles in Indonesia (AISI, 2017). To solve that problem, the red box for motorcycles are provided at the signalized intersection. Red box for the motorcycle at signalized intersections was developed from the concept of Advance Stop Line (ASL) for bicycles. The Red Box was developed to split the queue between motorcycles and other vehicles when waiting at red light. This paper aims to evaluate the influence of the red box dimension and red time operation differences. The survey was conducted as many as 30 cycles of traffic signals per day. The data were analyzed using software IBM SPSS Statistics 20 by using Analysis of Variance (ANOVA) to obtain p-value (significant). The analysis shows that there are insignificant influences between the occupancy rates to the dimension of Red Box. Furthermore, that there is a significant difference that shows the dependency of only motorcycles in the Red Box Area towards red time operation.

  11. Nondestructive testing of the low-level radioactive waste drums for uni-axial compressive strength and free liquid content

    International Nuclear Information System (INIS)

    Yu Geping; Chang Mingyu; Wang Yeajeng; Chu, David S.L.; Ju Yihzen

    1992-01-01

    This paper summarizes the nondestructive test to determine the uni-axial compressive strength and free water content of solidified low level radioactive waste. The uni-axial compressive strength is determined by ultrasonic wave propagation speed, and the results are compared with those of compressive tests. Three methods of detecting the surface free water by ultrasonic testing are established, the ultrasonic wave speed, wave form and pulse height are used to determine the existence and amount of the surface free liquid. Possible difficulties are discussed. (author)

  12. The role of testing realism on experimentally obtained stereotype strength.

    Science.gov (United States)

    Hoffmann, Errol R; Whitfield, Richard C

    2011-01-01

    It has been shown (Hoffmann 2009) that pencil-and-paper tests, when used to determine stereotype strength, may yield data quite different to that obtained from hardware tests. The purpose of this research was to determine the level of realism required in order to have stereotypes that are consistent with real-world values. It is surprising that there does not appear to be any published research addressing this problem; all previous researches have considered either paper/pencil or hardware tests or sometimes both, but no level of simulation in between these techniques. In order to determine the effect of level of testing realism, a specific example was chosen to test, that of water tap operation stereotypes. Tests used verbal questioning, photographs of tap arrangements, a partial hardware arrangement and finally a full hardware setup. The results of these four levels of realism were very different and illustrated that, only with a full realistic simulation, did participants respond as might be expected in a real-world environment, illustrating the importance of testing realism when determining population stereotypes. This result has strong implications for product designers when selecting appropriate layouts of displays and controls and the linkages relating these. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  13. COMPUTER MODEL AND SIMULATION OF A GLOVE BOX PROCESS

    International Nuclear Information System (INIS)

    Foster, C.

    2001-01-01

    The development of facilities to deal with the disposition of nuclear materials at an acceptable level of Occupational Radiation Exposure (ORE) is a significant issue facing the nuclear community. One solution is to minimize the worker's exposure though the use of automated systems. However, the adoption of automated systems for these tasks is hampered by the challenging requirements that these systems must meet in order to be cost effective solutions in the hazardous nuclear materials processing environment. Retrofitting current glove box technologies with automation systems represents potential near-term technology that can be applied to reduce worker ORE associated with work in nuclear materials processing facilities. Successful deployment of automation systems for these applications requires the development of testing and deployment strategies to ensure the highest level of safety and effectiveness. Historically, safety tests are conducted with glove box mock-ups around the finished design. This late detection of problems leads to expensive redesigns and costly deployment delays. With wide spread availability of computers and cost effective simulation software it is possible to discover and fix problems early in the design stages. Computer simulators can easily create a complete model of the system allowing a safe medium for testing potential failures and design shortcomings. The majority of design specification is now done on computer and moving that information to a model is relatively straightforward. With a complete model and results from a Failure Mode Effect Analysis (FMEA), redesigns can be worked early. Additional issues such as user accessibility, component replacement, and alignment problems can be tackled early in the virtual environment provided by computer simulation. In this case, a commercial simulation package is used to simulate a lathe process operation at the Los Alamos National Laboratory (LANL). The Lathe process operation is indicative of

  14. Design, construction and performance evaluation of aBox type solar cooker with a glazing wiper mechanism

    Directory of Open Access Journals (Sweden)

    Zeleke Ademe

    2018-01-01

    Full Text Available This research work describes the performance evaluation of a double-glazed box-type solar oven with three reflectors and with a vapor wiper mechanism fabricated using locally available materials. The box cooker has external box dimensions of 600 mm × 600 mm × 250 mm and pyramidal internal box dimensions of 460 mm × 460 mm top face and 300 mm × 300 mm bottom face with depth of 150 mm. The thermal performance was tested as per the ASAE International Test procedure and Bureau of Indian Standards (BIS for testing the thermal performance of a box-type solar cooker. The obtained test results after employing required calculations were figures of merit F1 = 0.123 Km2/W, F2 = 0.540, the standard cooking power P50 = 36 W and the cumulative efficiency to be 22%, whereas with the application of the wiper mechanism, it was found that F1 = 0.123, F2 = 0.827, the standard cooking power (P50 = 51 W, and the cumulative efficiency to be 31.4%. The standard boiling time of 1.43 kg of water was calculated to be 53.54 and 88.84 minutes for the cooker with and without the application of wiper mechanism respectively. The thermal distribution of the cooker was modeled using interior box geometry as a boundary condition with ANSYS 15.0. The temperature distribution inside the box was simulated and the maximum wall temperature was found to be 139 ℃. This was lower than the experimental results by 22 ℃. The method of modeling and simulation of the cooker with and without a wiper mechanism is similar except for the variation of the transmittance of the glass due to shading of vapor which can be deducted from the cumulative efficiency for the latter case. The results show that using the vapor wiper mechanism increases the cumulative efficiency by 9.4% and reduces the boiling time by 35.3 minutes. Finally, the techno-economic analysis shows that the cooker with a vapor wiper mechanism has a good reliability for outdoor cooking of food and is economically feasible.

  15. Dielectric strength test to protection elements for live lines works

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Pinto-Salamanca

    2017-06-01

    Full Text Available This paper presents the design and assembly of a system of tests of sustained voltage to elements and equipment used in live line maneuvers through tests on gloves and dielectric rods, as these are the first points of contact to ensure safe operations. It means an advance for the creation of a laboratory certified in this type of tests at Universidad Pedagógica y Tecnológica de Colombia (UPTC Faculty of Duitama, considering that currently there are not laboratories that provide this service in Boyacá and Casanare. Dielectric strength tests were performed on personal protection elements and equipment under the parameters of ASTM D120, ASTM F496, ISO 60903, ASTM-F711 and IEEE 978, developing an assembly for testing gloves and dielectric rods with voltage levels up to 15 kV. The results validate the proposed system to outlook of circuit design and implementation, where tests were performed to establish dielectric capacities, in operating under open circuit conditions, with resistive load or short circuit. The compliance with the regulations established under the test sequences of safety parameters for the system and the follow-up to the tests was verified through the use of a management system for the generation of concepts of approval or rejection of the tested elements.

  16. An evaluation of the +/-45 deg tensile test for the determination of the in-plane shear strength of composite materials

    Science.gov (United States)

    Kellas, S.; Morton, J.; Jackson, K. E.

    1991-01-01

    The applicability of the +/-45 deg tensile test for the determination of the in-plane shear strength of advanced composite laminates is studied. The assumptions used for the development of the shear strength formulas were examined, and factors such as the specimen geometry and stacking sequence were assessed experimentally. It was found that the strength of symmetric and balanced +/-45 deg laminates depends primarily upon the specimen thickness rather than the specimen width. These findings have important implications for the +/-45 deg tensile test which is recommended by several organizations for the determination of the in-plane shear stress/strain response and the shear strength of continuous fiber reinforced composites. Modifications to the recommended practices for specimen selection and shear strength determination are suggested.

  17. Ponded infiltration tests at the Box Canyon site: data report and preliminary analysis

    International Nuclear Information System (INIS)

    Cook, Paul; Faybishenko, Boris; Freifeld, Barry; Jacobsen, Janet; Lee, Ki Ha; Salve, Rohit; Zawislanski, Peter

    1998-01-01

    We discuss the design and present the main results of a two-week ponded infiltration test conducted in 1996 at the Box Canyon site near the Idaho National Engineering and Environmental Laboratory. To investigate liquid flow and chemical transport in fractured basalt, the following types of instruments were installed in boreholes: tensiometers, suction lysimeters, thermistors, time domain reflectrometry probes, and electrical resisitivity probes. These probes were installed using an innovative technology of borehole instrumentation and completion using polyurethane foam injection. The probes were attached to plastic packers that were inflated using the polyurethane foam, and then the space between packers was back-filled with the foam in order to ensure the isolation of the instruments at different depths. Polyurethane foam showed great promise in enabling rapid, cost-effective installation of sensors and probes in fractured rock. A ponded infiltration test was conducted from 8/27/96 to 9/9/96, by maintaining water to an average depth of 23 cm in a rectangular infiltration pond. Within the 7 x 8 m pond, nine local infiltrometers (0.25 m diameter) were-installed to determine local values of the water flux. A slug of conservative tracer (KM) was added to the pond on 9/2/96, yielding a tracer concentration in the pond of approximately 3 g/L. The water supply to the pond was halted for two days so that the tracer concentration in the pond water would remain essentially constant. Thereafter, the water supply was re-established to maintain a constant water level. Installation procedures and measurement results for each type of probe are presented, along with a description of the data acquisition system. The attachments include a description of the calibration and testing of instrumentation. The data files can be found at the FTP site zenitMnel/ or the Web site http://www- esd.lbl.gov/ERT/inel/inel.htrnl

  18. Responsiveness of the Countermovement Jump and Handgrip Strength to an Incremental Running Test in Endurance Athletes: Influence of Sex.

    Science.gov (United States)

    García-Pinillos, Felipe; Delgado-Floody, Pedro; Martínez-Salazar, Cristian; Latorre-Román, Pedro Á

    2018-03-01

    The present study analyzed the acute effects of an incremental running test on countermovement jump (CMJ) and handgrip strength performance in endurance athletes, considering the effect of post-exercise recovery time and sex. Thirty-three recreationally trained long-distance runners, 20 men and 13 women, participated voluntarily in this study. The participants performed the Léger test, moreover, the CMJ and handgrip strength tests were carried out before and after the running test and during different stages of recovery (at the 1st min of recovery (posttest1), 5th min of recovery (posttest2), and 10th min of recovery (posttest3)). Two-way analysis of variance revealed a significant improvement in the CMJ (pre-posttest1, p = 0.001) and handgrip strength (pre-posttest2, p = 0.017) during recovery time. The Pearson's Chi-2 test showed no significant relationship ( p ≥ 0.05) between sex and post-activation potentiation (PAP). A linear regression analysis pointed to heart rate recovery as a predictive factor of CMJ improvement (PAP). In conclusion, despite significant fatigue reached during the Léger test, the long-distance runners did not experience an impaired CMJ and handgrip strength performance, either men or women, achieving an improvement (PAP) in posttest conditions. The results obtained showed no significant relationship between sex and PAP. Moreover, significant effect of recovery after running at high intensity on CMJ performance and handgrip strength was found. Finally, the data suggest that PAP condition can be predicted by heart rate recovery in endurance runners.

  19. Ultimate Tensile Strength as a Function of Test Rate for Various Ceramic Matrix Composites at Elevated Temperatures

    Science.gov (United States)

    Choi, Sung R.; Bansal, Narottam P.; Gyekenyesi, John P.

    2002-01-01

    Ultimate tensile strength of five different continuous fiber-reinforced ceramic composites, including SiC/BSAS (2D 2 types), SiC/MAS-5 (2D), SiC/SiC (2D enhanced), and C/SiC(2D) was determined as a function of test rate at I 100 to 1200 'C in air. All five composite materials exhibited a significant dependency of ultimate strength on test rate such that the ultimate strength decreased with decreasing test rate, similar to the behavior observed in many advanced monolithic ceramics at elevated temperatures. The application of the preloading technique as well as the prediction of life from one loading configuration (constant stress rate) to another (constant stress loading) for SiC/BSAS suggested that the overall macroscopic failure mechanism of the composites would be the one governed by a power-law type of damage evolution/accumulation, analogous to slow crack growth commonly observed in advanced monolithic ceramics.

  20. Functional redundancy and/or ongoing pseudogenization among F-box protein genes expressed in Arabidopsis male gametophyte.

    Science.gov (United States)

    Ikram, Sobia; Durandet, Monique; Vesa, Simona; Pereira, Serge; Guerche, Philippe; Bonhomme, Sandrine

    2014-06-01

    F-box protein genes family is one of the largest gene families in plants, with almost 700 predicted genes in the model plant Arabidopsis. F-box proteins are key components of the ubiquitin proteasome system that allows targeted protein degradation. Transcriptome analyses indicate that half of these F-box protein genes are found expressed in microspore and/or pollen, i.e., during male gametogenesis. To assess the role of F-box protein genes during this crucial developmental step, we selected 34 F-box protein genes recorded as highly and specifically expressed in pollen and isolated corresponding insertion mutants. We checked the expression level of each selected gene by RT-PCR and confirmed pollen expression for 25 genes, but specific expression for only 10 of the 34 F-box protein genes. In addition, we tested the expression level of selected F-box protein genes in 24 mutant lines and showed that 11 of them were null mutants. Transmission analysis of the mutations to the progeny showed that none of the single mutations was gametophytic lethal. These unaffected transmission efficiencies suggested leaky mutations or functional redundancy among F-box protein genes. Cytological observation of the gametophytes in the mutants confirmed these results. Combinations of mutations in F-box protein genes from the same subfamily did not lead to transmission defect either, further highlighting functional redundancy and/or a high proportion of pseudogenes among these F-box protein genes.

  1. Effects of reclaimed asphalt pavement on indirect tensile strength test of conditioned foamed asphalt mix

    International Nuclear Information System (INIS)

    Katman, Herda Yati; Norhisham, Shuhairy; Ismail, Norlela; Ibrahim, Mohd Rasdan; Matori, Mohd Yazip

    2013-01-01

    This paper presents the results of Indirect Tensile Strength (ITS) Test for samples prepared with reclaimed asphalt pavement (RAP). Samples were conditioned in water at 25°C for 24 hours prior to testing. Results show that recycled aggregate from reclaimed asphalt pavement performs as well as virgin aggregate.

  2. Experimental Study on the Compressive Strength of Big Mobility Concrete with Nondestructive Testing Method

    Directory of Open Access Journals (Sweden)

    Huai-Shuai Shang

    2012-01-01

    Full Text Available An experimental study of C20, C25, C30, C40, and C50 big mobility concrete cubes that came from laboratory and construction site was completed. Nondestructive testing (NDT was carried out using impact rebound hammer (IRH techniques to establish a correlation between the compressive strengths and the rebound number. The local curve for measuring strength of the regression method is set up and its superiority is proved. The rebound method presented is simple, quick, and reliable and covers wide ranges of concrete strengths. The rebound method can be easily applied to concrete specimens as well as existing concrete structures. The final results were compared with previous ones from the literature and also with actual results obtained from samples extracted from existing structures.

  3. Sand box experiments with bioclogging of porous media: Hydraulic conductivity reductions

    DEFF Research Database (Denmark)

    Seifert, Dorte; Engesgaard, Peter

    2012-01-01

    Tracer experiments during clogging and de-clogging experiments in a 2D sand box were via an image analysis used to establish a data set on the relation between changes in hydraulic conductivity (K) and relative porosity (β). Clogging appears to create a finger-like tracer transport, which could...... and closer to the substrate source during the experiments suggesting that the zone of clogging moved upstream. Three clogging models, K(β), from the literature were tested for their ability to describe the temporal changes in clogging at the scale of the sand box; the model of Clement et al. (1996......) that makes no assumption on biomass distribution, the plug formation model of Thullner et al. (2002a), and the biofilm-plug formation model of Vandevivere (1995). The plug formation and biofilm-plug formation models both match the observed changes between the hydraulic conductivity of the sand box...

  4. 49 CFR 178.512 - Standards for steel or aluminum boxes.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Standards for steel or aluminum boxes. 178.512... aluminum boxes. (a) The following are identification codes for steel or aluminum boxes: (1) 4A for a steel box; and (2) 4B for an aluminum box. (b) Construction requirements for steel or aluminum boxes are as...

  5. Comparison of shear test methods for evaluating the bond strength of resin cement to zirconia ceramic.

    Science.gov (United States)

    Kim, Jae-Hoon; Chae, Soyeon; Lee, Yunhee; Han, Geum-Jun; Cho, Byeong-Hoon

    2014-11-01

    This study compared the sensitivity of three shear test methods for measuring the shear bond strength (SBS) of resin cement to zirconia ceramic and evaluated the effects of surface treatment methods on the bonding. Polished zirconia ceramic (Cercon base, DeguDent) discs were randomly divided into four surface treatment groups: no treatment (C), airborne-particle abrasion (A), conditioning with Alloy primer (Kuraray Medical Co.) (P) and conditioning with Alloy primer after airborne-particle abrasion (AP). The bond strengths of the resin cement (Multilink N, Ivoclar Vivadent) to the zirconia specimens of each surface treatment group were determined by three SBS test methods: the conventional SBS test with direct filling of the mold (Ø 4 mm × 3 mm) with resin cement (Method 1), the conventional SBS test with cementation of composite cylinders (Ø 4 mm × 3 mm) using resin cement (Method 2) and the microshear bond strength (μSBS) test with cementation of composite cylinders (Ø 0.8 mm × 1 mm) using resin cement (Method 3). Both the test method and the surface treatment significantly influenced the SBS values. In Method 3, as the SBS values increased, the coefficients of variation decreased and the Weibull parameters increased. The AP groups showed the highest SBS in all of the test methods. Only in Method 3 did the P group show a higher SBS than the A group. The μSBS test was more sensitive to differentiating the effects of surface treatment methods than the conventional SBS tests. Primer conditioning was a stronger contributing factor for the resin bond to zirconia ceramic than was airborne-particle abrasion.

  6. Cable tray ultimate strength test employing a large shaker table

    Energy Technology Data Exchange (ETDEWEB)

    Komatsu, K.; Myojin, K.; Imai, K. [The Kansai Electric Power Co., Osaka (Japan); Fuyama, H. [Mitsubishi Heavy Industries Ltd, Takasago (Japan); Kokubo, E. [Mitsubishi Heavy Industdries Ltd, Kobe (Japan)

    2004-07-01

    Ultimate behaviors of cable trays, used in nuclear plants, have not been well studied since cable trays are designed based on conservative design criteria. In this study, by employing a large shaker table, an ultimate strength test was conducted for cable trays used in nuclear power plants. This report describes the results of shaker table test. The following results were obtained. First, in an S{sub 2} earthquake, the damping ratio was so large - more than 30% due to the rubbing of cables - that a large response was not present and the strains in the support were within the elastic limits. Secondly, the support was strong enough to sustain the cable trays even when the strain in the support was 20 times larger than the elastic limit. (authors)

  7. A Study on the Small Punch Test for Fracture Strength Evaluation of CANDU Pressure Tube Embrittled by Hydrogen

    International Nuclear Information System (INIS)

    Nho, Seung Hwan; Ong, Jang Woo; Yu, Hyo Sun; Chung, Se Hi

    1996-01-01

    The purpose of this study is to investigate the usefulness of small punch(SP) test using miniaturized specimens as a method for fracture strength evaluation of CANDU pressure tube embrittled by hydrogen. According to the test results, the fracture strength evaluation as a function of hydrogen concentration at -196 .deg. C was much better than that at room temperature, as the difference of SP fracture energy(Esp) with hydrogen concentration was more significant at -196 .deg. C than at room temperature for the hydrogen concentration up to 300ppm-H. It was also observed that the peak of average AE energy, the cumulative average AE energy and the cumulative average AE energy per equivalent fracture, strain increased with the increase of hydrogen concentration. From the results of load-displacement behaviors, Esp behaviors, macro- and micro-SEM fractographs and AE test it has been concluded that the SP test method using miniaturized specimen(10mmx10mmx0.5mm) will be a useful test method to evaluate the fracture strength for CANDU pressure tube embrittled by hydrogen

  8. Relativistic particle in a box

    OpenAIRE

    Alberto, P.; Fiolhais, Carlos; Gil, Victor

    1996-01-01

    The problem of a relativistic spin 1/2 particle confined to a one-dimensional box is solved in a way that resembles closely the solution of the well known quantum-mechanical textbook problem of a non-relativistic particle in a box. The energy levels and probability density are computed and compared with the non-relativistic case

  9. What Makes a Better Box?

    Science.gov (United States)

    Moyer, Richard; Everett, Susan

    2010-01-01

    Every morning, many Americans start their day with a bowl of cereal. Some spend time while they eat breakfast reading the back of the cereal box, but few consider its size, shape, and construction, or realize that it was designed by an engineer. This article describes a lesson in which students design, build, and critique cereal boxes. The lesson…

  10. Test method research on weakening interface strength of steel - concrete under cyclic loading

    Science.gov (United States)

    Liu, Ming-wei; Zhang, Fang-hua; Su, Guang-quan

    2018-02-01

    The mechanical properties of steel - concrete interface under cyclic loading are the key factors affecting the rule of horizontal load transfer, the calculation of bearing capacity and cumulative horizontal deformation. Cyclic shear test is an effective method to study the strength reduction of steel - concrete interface. A test system composed of large repeated direct shear test instrument, hydraulic servo system, data acquisition system, test control software system and so on is independently designed, and a set of test method, including the specimen preparation, the instrument preparation, the loading method and so on, is put forward. By listing a set of test results, the validity of the test method is verified. The test system and the test method based on it provide a reference for the experimental study on mechanical properties of steel - concrete interface.

  11. Tensile strength and fatigue strength of 6061 aluminum alloy friction welded joints

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, H.; Tsujino, R. [Osaka Inst. of Tech., Asahi-ku Osaka (Japan); Sawai, T. [Osaka Sangyo Univ., Daito (Japan); Yamamoto, Y. [Setsunan Univ., Neyagawa (Japan); Ogawa, K. [Osaka Prefecture Univ., Sakai (Japan); Suga, Y. [Keio Univ., Kohoku-ku, Yokohama (Japan)

    2002-07-01

    Friction welding of 6061 aluminum alloy was carried out in order to examine the relationship between deformation heat input in the upset stage and joint performance. The joint performance was evaluated by tensile testing and fatigue testing. Stabilized tensile strength was obtained when the deformation heat input in the upset stage exceeded 200 J/s. Weld condition at the weld interface and the width of softened area affected fatigue strength more than tensile strength. That is, when the weld condition at the weld interface is good and the softened area is wide, fatigue strength increases. On the other hand, when the weld condition at the weld interface is good and the softened area is narrow, and when the weld condition at the weld interface is somewhat poor in spite of the wide softened area, fatigue strength decreases. The fatigue limit obtained by the fatigue testing revealed that, when the deformation heat input in the upset stage exceeded a certain value, sound joints could be produced. (orig.)

  12. Infectious disease and boxing.

    Science.gov (United States)

    King, Osric S

    2009-10-01

    There are no unique boxing diseases but certain factors contributing to the spread of illnesses apply strongly to the boxer, coach, and the training facility. This article examines the nature of the sport of boxing and its surrounding environment, and the likelihood of spread of infection through airborne, contact, or blood-borne routes of transmission. Evidence from other sports such as running, wrestling, and martial arts is included to help elucidate the pathophysiologic elements that could be identified in boxers.

  13. Ego depletion in color priming research: self-control strength moderates the detrimental effect of red on cognitive test performance.

    Science.gov (United States)

    Bertrams, Alex; Baumeister, Roy F; Englert, Chris; Furley, Philip

    2015-03-01

    Colors have been found to affect psychological functioning. Empirical evidence suggests that, in test situations, brief perceptions of the color red or even the word "red" printed in black ink prime implicit anxious responses and consequently impair cognitive performance. However, we propose that this red effect depends on people's momentary capacity to exert control over their prepotent responses (i.e., self-control). In three experiments (Ns = 66, 78, and 130), first participants' self-control strength was manipulated. Participants were then primed with the color or word red versus gray prior to completing an arithmetic test or an intelligence test. As expected, self-control strength moderated the red effect. While red had a detrimental effect on performance of participants with depleted self-control strength (ego depletion), it did not affect performance of participants with intact self-control strength. We discuss implications of the present findings within the current debate on the robustness of priming results. © 2015 by the Society for Personality and Social Psychology, Inc.

  14. Naesliden Project: direct shear tests of filled and unfilled joints

    Energy Technology Data Exchange (ETDEWEB)

    Ludvig, B.

    1980-05-15

    Joints from the Naesliden mine have been tested in a small field shear box and in a large shear rig. The large shear rig is described in detail, and its ability to test joints with an area of 600 mc/sup 2/ at a maximum normal stress of up to 20 MPa is emphasized. The stiffness and shear strength of the discontinuities in the Naesliden mine is presented. The values estimated at direct shear tests are compared with results from in situ measurements and tests on drillcores. The results show that the in situ measurements give lower values for the shear resistance than the direct shear tests. Estimation of the normal stiffness for joints in drill cores gave much higher stiffness than the estimations in the shear rig.

  15. Effects of Muscle Strength and Balance Control on Sit-to-Walk and Turn Durations in the Timed Up and Go Test.

    Science.gov (United States)

    Chen, Tzurei; Chou, Li-Shan

    2017-12-01

    To examine the association of muscle strength and balance control with the amount of time taken to perform sit-to-walk (STW) or turning components of the Timed Up and Go (TUG) test in older adults. Correlations; multiple regression models. General community. Older adults (N=60) age >70 years recruited from the community. Not applicable. Muscle strength, balance control, and TUG test performance time. Muscle strength was quantified by peak joint moments during the isometric maximal voluntary contraction test for bilateral hip abductors, knee extensors, and ankle plantar flexors. Balance control was assessed with the Berg Balance Scale, Fullerton Advanced Balance Scale, and center of mass and ankle inclination angle derived during the TUG test performance. We found that balance control measures were significantly associated with both STW and turning durations even after controlling for muscle strength and other confounders (STW duration: Pbalance control is an important factor that contributes to longer STW and turning durations on the TUG test. Furthermore, strength has a higher association with STW than turning duration. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. Cosmetic Foot Surgery: Fashion's Pandora's Box

    Science.gov (United States)

    ... Fashion’s Pandora’s Box? A A A | Print | Share Cosmetic Foot Surgery: Fashion’s Pandora’s Box? Foot and ankle ... extreme and imprudent as it may sound, the cosmetic surgery craze is not just for faces anymore— ...

  17. Evaluating Upper-Body Strength and Power From a Single Test: The Ballistic Push-up.

    Science.gov (United States)

    Wang, Ran; Hoffman, Jay R; Sadres, Eliahu; Bartolomei, Sandro; Muddle, Tyler W D; Fukuda, David H; Stout, Jeffrey R

    2017-05-01

    Wang, R, Hoffman, JR, Sadres, E, Bartolomei, S, Muddle, TWD, Fukuda, DH, and Stout, JR. Evaluating upper-body strength and power from a single test: the ballistic push-up. J Strength Cond Res 31(5): 1338-1345, 2017-The purpose of this study was to examine the reliability of the ballistic push-up (BPU) exercise and to develop a prediction model for both maximal strength (1 repetition maximum [1RM]) in the bench press exercise and upper-body power. Sixty recreationally active men completed a 1RM bench press and 2 BPU assessments in 3 separate testing sessions. Peak and mean force, peak and mean rate of force development, net impulse, peak velocity, flight time, and peak and mean power were determined. Intraclass correlation coefficients were used to examine the reliability of the BPU. Stepwise linear regression was used to develop 1RM bench press and power prediction equations. Intraclass correlation coefficient's ranged from 0.849 to 0.971 for the BPU measurements. Multiple regression analysis provided the following 1RM bench press prediction equation: 1RM = 0.31 × Mean Force - 1.64 × Body Mass + 0.70 (R = 0.837, standard error of the estimate [SEE] = 11 kg); time-based power prediction equation: Peak Power = 11.0 × Body Mass + 2012.3 × Flight Time - 338.0 (R = 0.658, SEE = 150 W), Mean Power = 6.7 × Body Mass + 1004.4 × Flight Time - 224.6 (R = 0.664, SEE = 82 W); and velocity-based power prediction equation: Peak Power = 8.1 × Body Mass + 818.6 × Peak Velocity - 762.0 (R = 0.797, SEE = 115 W); Mean Power = 5.2 × Body Mass + 435.9 × Peak Velocity - 467.7 (R = 0.838, SEE = 57 W). The BPU is a reliable test for both upper-body strength and power. Results indicate that the mean force generated from the BPU can be used to predict 1RM bench press, whereas peak velocity and flight time measured during the BPU can be used to predict upper-body power. These findings support the potential use of the BPU as a valid method to evaluate upper-body strength and power.

  18. Fuel assembly and fuel channel box

    International Nuclear Information System (INIS)

    Sakuma, Toraki; Hirakawa, Hiromasa; Ishizaki, Hideaki; Nakajima, Junjiro; Aizawa, Yasuhiro.

    1992-01-01

    A fuel channel box has a square cylindrical shape and, in the transversal cross sectional shape, the wall thickness of a corner portion is greater than that of a central portion of the side wall except for an upper portion thereof. The upper portion of the channel box includes a region to be in contact with an upper lattice plate and a region to attach a channel spacer. Then, the wall thickness of these regions is uniform in the transversal cross section and they have the same wall thickness with that of the corner portion which has the increased wall thickness. With such a constitution, the upper portion of the channel box receives a counter force applied from the upper lattice plate upon occurrence of earthquakes and moderate it to reduce local stresses and deformation. Further, a similar region with increased wall thickness is disposed also to the lower portion of the channel box, thereby enabling to suppress the amount of coolants leaked from a portion between the lower portion and a lower tie plate, and improve the mechanical integrity of the channel box. (I.N.)

  19. Getting started with Citrix VDI-in-a-Box

    CERN Document Server

    Brown, Stuart Arthur

    2013-01-01

    A practical and fast-paced guide that gives you all the information you need to simplify and streamline virtual desktops so you get a production-quality solution while instantly lowering your costs and improving security.Getting Started with Citrix VDI-in-a-Box is great for IT professionals who are new to VDI-in-a-Box and who are looking for a good grounding in the product. You may be planning to research VDI-in-a-Box in more detail, or you may be tasked with researching how VDI-in-a-Box could improve the productivity of your organization. No prior knowledge of VDI-in-a-Box is required, just a

  20. Spacer for supporting fuel element boxes

    International Nuclear Information System (INIS)

    Wild, E.

    1979-01-01

    A spacer plate unit arranged externally on each side and at a predetermined level of a polygonal fuel element box for mutually supporting, with respect to one another, a plurality of the fuel element boxes forming a fuel element bundle, is formed of a first and a second spacer plate part each having the same length and the same width and being constituted of unlike first and second materials, respectively. The first and second spacer plate parts of the several spacer plate units situated at the predetermined level are arranged in an alternating continuous series when viewed in the peripheral direction of the fuel element box, so that any two spacer plate units belonging to face-to-face oriented sides of two adjoining fuel element boxes in the fuel element bundle define interfaces of unlike materials

  1. Tinetti mobility test is related to muscle mass and strength in non-institutionalized elderly people.

    Science.gov (United States)

    Curcio, Francesco; Basile, Claudia; Liguori, Ilaria; Della-Morte, David; Gargiulo, Gaetano; Galizia, Gianluigi; Testa, Gianluca; Langellotto, Assunta; Cacciatore, Francesco; Bonaduce, Domenico; Abete, Pasquale

    2016-12-01

    Elderly people are characterized by a high prevalence of falls and sarcopenia. However, the relationship among Tinetti mobility test (TMT) score, a powerful tool to detect elderly people at risk of falls, and sarcopenia is still not thoroughly investigated. Thus, to determine the relationship between TMT score and muscle mass and strength, 337 elderly participants (mean age 77.1 ± 6.9 years) admitted to comprehensive geriatric assessment were enrolled. TMT score, muscle mass by bioimpedentiometer, and muscle strength by grip strength were evaluated. Muscle mass progressively decreased as TMT score decreased (from 15.3 ± 3.7 to 8.8 ± 1.8 kg/m 2 ; p for trend strength decreased progressively as Tinetti score decreased (from 34.7 ± 8.0 to 23.7 ± 8.7 kg; p for trend 0.001). Linear regression analysis demonstrated that TMT score is linearly related with muscle mass (y = 4.5x + 0.4, r = 0.61; p strength (y = 14.0x + 0.8, r = 0.53; p strength (r = 0.39, p = 0.046). The present study indicates that TMT score is significantly related to muscle mass and strength in non-institutionalized elderly participants. This evidence suggests that TMT score, together with evaluation of muscle mass and strength, may identify sarcopenic elderly participants at high risk of falls.

  2. Influence of steel fibers on the shear and flexural performance of high-strength concrete beams tested under blast loads

    Science.gov (United States)

    Algassem, O.; Li, Y.; Aoude, H.

    2017-09-01

    This paper presents the results of a study examining the effect of steel fibres on the blast behaviour of high-strength concrete beams. As part of the study, a series of three large-scale beams built with high-strength concrete and steel fibres are tested under simulated blast loading using the shock-tube testing facility at the University of Ottawa. The specimens include two beams built with conventional high-strength concrete (HSC) and one beam built with high-strength concrete and steel fibres (HSFRC). The effect of steel fibres on the blast behaviour is examined by comparing the failure mode, mid-span displacements and, overall blast resistance of the specimens. The results show that the addition of steel fibres in high-strength concrete beams can prevent shear failure and substitute for shear reinforcement if added in sufficient quantity. Moreover, the use of steel fibres improves flexural response under blast loading by reducing displacements and increasing blast capacity. Finally, the provision of steel fibres is found to improve the fragmentation resistance of high-strength concrete under blast loads.

  3. Evaluation of dynamic compaction of low level waste burial trenches containing B-25 boxes

    International Nuclear Information System (INIS)

    McMullin, S.R.

    1994-01-01

    The Savannah River Site, owned by the US Department of Energy, is preparing to close an additional 13.8 ha of burial grounds under the Resource Conservation Recovery Act. In preparation for this closure, the dynamic compaction facility was designed and constructed to address unresolved design issues. Among these issues is the evaluation of the ability for dynamic compaction to consolidate buried low level waste containers. A model burial trench containing simulated clean wastes was dynamically compacted, after which the materials were excavated and compaction quantified. The test determined that under existing success criteria, the bottom tier of stacked B-25 boxes were not being consolidated. A quasi-structural layer was formed midway through the stacked boxes, which absorbed the compactive energy. Resulting from these observations and the data collected, a new success criterion is recommended which depends on the relative displacement per drop. The test successfully demonstrated that dynamic compaction will consolidate buried metal boxes

  4. Glove box adaptation, installation and commissioning of WD-XRF system for determination of PuO2 in MOX fuel samples

    International Nuclear Information System (INIS)

    Aher, Sachin; Pandey, Ashish; Khan, F.A.; Das, D.K.; Kumar, Surendra; Behere, P.G.; Mohd Afzal

    2015-01-01

    Glove Box facility forms the foremost important confinement system at nuclear fuel fabrication facility for handling of Plutonium based MOX fuels. Due to limited resources of Natural Uranium and maximum utilization of thorium, India has adopted 'Close Fuel Cycle Strategy' which involves use of Plutonium based fuels in Thermal and Fast reactors. Plutonium being radio toxic material with a higher biological half-life, Plutonium based fuel fabrication facility requires special techniques and confinement as a primary method for protection against spreading of powder contamination. Glove Box along with dynamic ventilation and HEPA Filters forms the preeminent facility for safe handling of plutonium based MOX fuels. Various equipment's, systems and instruments associated with MOX fuel production are need to be adapted inside the Glove Box with considerations of safety, ergonomics, accessibility for operations and maintenance, connections of various feed through like electrical connections, gas line supply etc. Quality Control plays the vital role in production of MOX fuels to ensure the finest quality of product to meet the defined specifications of MOX fuels. Presently AFFF is fabricating MOX fuel containing 21% and 28% PuO 2 along with DDUO 2 the first core of PFBR. Precise quantification of PuO 2 in MOX fuel pellets is necessary process control steps after batch preparation in Milling and Mixing operation. At AFFF, WD-XRF is one of the system used for determination of percentage of PuO 2 in MOX fuel batch. Glove Box adaptation of WD-XRF system along with 30 Tones Hydraulic press for sample preparation is being carried out in Type VI and Type IV Glove Boxes connected through transfer tunnel. Due to restrictions of space inside the Glove Box, a special mechanism is developed and installed for safe titling of WD-XRF system inside the Glove Box during the need of maintenance. These Glove Boxes are leak tested by various leak testing technique to meet the

  5. Translucent zirconia in the ceramic scenario for monolithic restorations: A flexural strength and translucency comparison test.

    Science.gov (United States)

    Carrabba, Michele; Keeling, Andrew J; Aziz, Aziz; Vichi, Alessandro; Fabian Fonzar, Riccardo; Wood, David; Ferrari, Marco

    2017-05-01

    To compare three different compositions of Yttria-Tetragonal Zirconia Polycrystal (Y-TZP) ceramic and a lithium disilicate ceramic in terms of flexural strength and translucency. Three zirconia materials of different composition and translucency, Aadva ST [ST], Aadva EI [EI] and Aadva NT [NT](GC Tech, Leuven, Belgium) were cut with a slow speed diamond saw into beams and tabs in order to obtain, after sintering, dimensions of 1.2×4.0×15.0mm and 15.0×15.0×1.0mm respectively. Blocks of IPS e.max CAD LT were cut and crystallized in the same shapes and dimensions and used as a reference group [LD]. Beams (n=15) were tested in a universal testing machine for three-point bending strength. Critical fracture load was recorded in N, flexural strength (σ in MPa), Weibull modulus (m) and Weibull characteristic strength (σ 0 in MPa) were then calculated. Tabs (n=10) were measured with a spectrophotometer equipped with an integrating sphere. Contrast Ratios were calculated as CR=Yb/Yw. SEM of thermally etched samples coupled with lineal line analysis (n=6) was used to measure the tested zirconia grain size. Data were statistically analyzed. Differences in translucency, flexural strength and grain size were found to be statistically significant. CR increased and flexural strength decreased in the following order ST(σ 1215±190MPa, CR 0.74±0.01)>EI(σ 983±182MPa, CR 0.69±0.01)>NT(σ 539±66MPa, CR 0.65±0.01)>LD (σ 377±39Mpa, CR 0.56±0.02). The average grain size was different for the three zirconia samples with NT(558±38nm)>ST(445±34nm)>EI(284±11nm). The zirconia composition heavily influenced both the flexural strength and the translucency. Different percentages of Yittria and Alumina result in new materials with intermediate properties in between the conventional zirconia and lithium disilicate. Clinical indications for Zirconia Aadva NT should be limited up to three-unit span bridges. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Sport medicine and the ethics of boxing

    Science.gov (United States)

    Leclerc, S.; Herrera, C. D.

    1999-01-01

    In the light of medical evidence of the health risks associated with boxing, a watchful agnostic position among sport physicians is no longer justifiable. The normal activity in a boxing match places the athletes at risk of head injury, some of which may be difficult to detect and impossible to repair. This suggests that sport physicians and others expert in the prevention and diagnosis of such injuries should take a public stand against boxing, as other medical associations have. Although there is a need for continuing research into the health risks, doctors can in the interim take steps to increase public awareness of these risks. Sport physicians in particular can make a strong public statement by also ending their professional involvement with boxing. This need not be interpreted as paternalism; doctors are qualified neither to make laws nor to restrict private behaviour. Sport physicians are, however, well equipped to advise those who do make laws and those who choose to engage in boxing. In the end, because this stance against boxing will probably reduce the number of brain injuries in certain athletes, autonomy will be preserved, rather than restricted. 


 PMID:10597855

  7. Interseason variability in isokinetic strength and poor correlation with Nordic hamstring eccentric strength in football players.

    Science.gov (United States)

    van Dyk, N; Witvrouw, E; Bahr, R

    2018-04-25

    In elite sport, the use of strength testing to establish muscle function and performance is common. Traditionally, isokinetic strength tests have been used, measuring torque during concentric and eccentric muscle action. A device that measures eccentric hamstring muscle strength while performing the Nordic hamstring exercise is now also frequently used. The study aimed to investigate the variability of isokinetic muscle strength over time, for example, between seasons, and the relationship between isokinetic testing and the new Nordic hamstring exercise device. All teams (n = 18) eligible to compete in the premier football league in Qatar underwent a comprehensive strength assessment during their periodic health evaluation at Aspetar Orthopaedic and Sports Medicine Hospital in Qatar. Isokinetic strength was investigated for measurement error, and correlated to Nordic hamstring exercise strength. Of the 529 players included, 288 players had repeated tests with 1/2 seasons between test occasions. Variability (measurement error) between test occasions was substantial, as demonstrated by the measurement error (approximately 25 Nm, 15%), whether separated by 1 or 2 seasons. Considering hamstring injuries, the same pattern was observed among injured (n = 60) and uninjured (n = 228) players. A poor correlation (r = .35) was observed between peak isokinetic hamstring eccentric torque and Nordic hamstring exercise peak force. The strength imbalance between limbs calculated for both test modes was not correlated (r = .037). There is substantial intraindividual variability in all isokinetic test measures, whether separated by 1 or 2 seasons, irrespective of injury. Also, eccentric hamstring strength and limb-to-limb imbalance were poorly correlated between the isokinetic and Nordic hamstring exercise tests. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. North American box turtles: A natural history

    Science.gov (United States)

    Dodd, C. Kenneth

    2002-01-01

    Once a familiar backyard visitor in many parts of the United States and Mexico, the box turtle is losing the battle against extinction. In North American Box Turtles, C. Kenneth Dodd, Jr., has written the first book-length natural history of the twelve species and subspecies of this endangered animal. This volume includes comprehensive information on the species’ evolution, behavior, courtship and reproduction, habitat use, diet, population structure, systematics, and disease. Special features include color photos of all species, subspecies, and their habitats; a simple identification guide to both living and fossil species; and a summary of information on fossil Terrapene and Native uses of box turtles. End-of-chapter sections highlight future research directions, including the need for long-term monitoring and observation of box turtles within their natural habitat and conservation applications. A glossary and a bibliography of literature on box turtles accompany the text.

  9. A new set of ESTs from chickpea (Cicer arietinum L. embryo reveals two novel F-box genes, CarF-box_PP2 and CarF-box_LysM, with potential roles in seed development.

    Directory of Open Access Journals (Sweden)

    Shefali Gupta

    Full Text Available Considering the economic importance of chickpea (C. arietinum L. seeds, it is important to understand the mechanisms underlying seed development for which a cDNA library was constructed from 6 day old chickpea embryos. A total of 8,186 ESTs were obtained from which 4,048 high quality ESTs were assembled into 1,480 unigenes that majorly encoded genes involved in various metabolic and regulatory pathways. Of these, 95 ESTs were found to be involved in ubiquitination related protein degradation pathways and 12 ESTs coded specifically for putative F-box proteins. Differential transcript accumulation of these putative F-box genes was observed in chickpea tissues as evidenced by quantitative real-time PCR. Further, to explore the role of F-box proteins in chickpea seed development, two F-box genes were selected for molecular characterization. These were named as CarF-box_PP2 and CarF-box_LysM depending on their C-terminal domains, PP2 and LysM, respectively. Their highly conserved structures led us to predict their target substrates. Subcellular localization experiment revealed that CarF-box_PP2 was localized in the cytoplasm and CarF-box_LysM was localized in the nucleus. We demonstrated their physical interactions with SKP1 protein, which validated that they function as F-box proteins in the formation of SCF complexes. Sequence analysis of their promoter regions revealed certain seed specific cis-acting elements that may be regulating their preferential transcript accumulation in the seed. Overall, the study helped in expanding the EST database of chickpea, which was further used to identify two novel F-box genes having a potential role in seed development.

  10. A new set of ESTs from chickpea (Cicer arietinum L.) embryo reveals two novel F-box genes, CarF-box_PP2 and CarF-box_LysM, with potential roles in seed development.

    Science.gov (United States)

    Gupta, Shefali; Garg, Vanika; Bhatia, Sabhyata

    2015-01-01

    Considering the economic importance of chickpea (C. arietinum L.) seeds, it is important to understand the mechanisms underlying seed development for which a cDNA library was constructed from 6 day old chickpea embryos. A total of 8,186 ESTs were obtained from which 4,048 high quality ESTs were assembled into 1,480 unigenes that majorly encoded genes involved in various metabolic and regulatory pathways. Of these, 95 ESTs were found to be involved in ubiquitination related protein degradation pathways and 12 ESTs coded specifically for putative F-box proteins. Differential transcript accumulation of these putative F-box genes was observed in chickpea tissues as evidenced by quantitative real-time PCR. Further, to explore the role of F-box proteins in chickpea seed development, two F-box genes were selected for molecular characterization. These were named as CarF-box_PP2 and CarF-box_LysM depending on their C-terminal domains, PP2 and LysM, respectively. Their highly conserved structures led us to predict their target substrates. Subcellular localization experiment revealed that CarF-box_PP2 was localized in the cytoplasm and CarF-box_LysM was localized in the nucleus. We demonstrated their physical interactions with SKP1 protein, which validated that they function as F-box proteins in the formation of SCF complexes. Sequence analysis of their promoter regions revealed certain seed specific cis-acting elements that may be regulating their preferential transcript accumulation in the seed. Overall, the study helped in expanding the EST database of chickpea, which was further used to identify two novel F-box genes having a potential role in seed development.

  11. Box-Particle Cardinality Balanced Multi-Target Multi-Bernoulli Filter

    OpenAIRE

    L. Song; X. Zhao

    2014-01-01

    As a generalized particle filtering, the box-particle filter (Box-PF) has a potential to process the measurements affected by bounded error of unknown distributions and biases. Inspired by the Box-PF, a novel implementation for multi-target tracking, called box-particle cardinality balanced multi-target multi-Bernoulli (Box-CBMeMBer) filter is presented in this paper. More important, to eliminate the negative effect of clutters in the estimation of the numbers of targets, an improved generali...

  12. Experimental testing of a self-sensing FRP-concrete composite beam using FBG sensors

    Science.gov (United States)

    Wang, Yanlei; Hao, Qingduo; Ou, Jinping

    2009-03-01

    A new kind of self-sensing fiber reinforced polymer (FRP)-concrete composite beam, which consists of a FRP box beam combined with a thin layer of concrete in the compression zone, was developed by using two embedded FBG sensors in the top and bottom flanges of FRP box beam at mid-span section along longitudinal direction, respectively. The flexural behavior of the proposed self-sensing FRP-concrete composite beam was experimentally studied in four-point bending. The longitudinal strains of the composite beam were recorded using the embedded FBG sensors as well as the surfacebonded electric resistance strain gauges. Test results indicate that the FBG sensors can faithfully record the longitudinal strain of the composite beam in tension at bottom flange of the FRP box beam or in compression at top flange over the entire load range, as compared with the surface-bonded strain gauges. The proposed self-sensing FRP-concrete composite beam can monitor its longitudinal strains in serviceability limit state as well as in strength limit state, and will has wide applications for long-term monitoring in civil engineering.

  13. Modulating influences of memory strength and sensitivity of the retrieval test on the detectability of the sleep consolidation effect.

    Science.gov (United States)

    Schoch, Sarah F; Cordi, Maren J; Rasch, Björn

    2017-11-01

    Emotionality can increase recall probability of memories as emotional information is highly relevant for future adaptive behavior. It has been proposed that memory processes acting during sleep selectively promote the consolidation of emotional memories, so that neutral memories no longer profit from sleep consolidation after learning. This appears as a selective effect of sleep for emotional memories. However, other factors contribute to the appearance of a consolidation benefit and influence this interpretation. Here we show that the strength of the memory trace before sleep and the sensitivity of the retrieval test after sleep are critical factors contributing to the detection of the benefit of sleep on memory for emotional and neutral stimuli. 228 subjects learned emotional and neutral pictures and completed a free recall after a 12-h retention interval of either sleep or wakefulness. We manipulated memory strength by including an immediate retrieval test before the retention interval in half of the participants. In addition, we varied the sensitivity of the retrieval test by including an interference learning task before retrieval testing in half of the participants. We show that a "selective" benefit of sleep for emotional memories only occurs in the condition with high memory strength. Furthermore, this "selective" benefit disappeared when we controlled for the memory strength before the retention interval and used a highly sensitive retrieval test. Our results indicate that although sleep benefits are more robust for emotional memories, neutral memories similarly profit from sleep after learning when more sensitive indicators are used. We conclude that whether sleep benefits on memory appear depends on several factors, including emotion, memory strength and sensitivity of the retrieval test. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. 49 CFR 230.101 - Steam locomotive driving journal boxes.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Steam locomotive driving journal boxes. 230.101... Locomotives and Tenders Running Gear § 230.101 Steam locomotive driving journal boxes. (a) Driving journal boxes. Driving journal boxes shall be maintained in a safe and suitable condition for service. Not more...

  15. Feasibility and test-retest reliability of measuring lower-limb strength in young children with cerebral palsy

    NARCIS (Netherlands)

    Van Vulpen, L. F.; de Groot, Sonja; Becher, J. G.; De Wolf, G. S.; Dallmeijer, A. J.

    2013-01-01

    BACKGROUND: Quantifying leg muscle strength in young children with cerebral palsy (CP) is essential for identifying muscle groups for treatment and for monitoring progress. AIM: To study the feasibility, intratester reliability and the optimal test design (number of test occasions and repetitions)

  16. Feasibility and test-retest reliability of measuring lower‑limb strength in young children with cerebral palsy

    NARCIS (Netherlands)

    van Vulpen, L. F.; de Groot, S.; Becher, J. G.; de Wolf, G. S.; Dallmeijer, A. J.

    2013-01-01

    Quantifying leg muscle strength in young children with cerebral palsy (CP) is essential for identifying muscle groups for treatment and for monitoring progress. To study the feasibility, intratester reliability and the optimal test design (number of test occasions and repetitions) of measuring

  17. Acute Changes in Creatine Kinase Serum Levels in Adults Submitted a Static Stretching and Maximal Strength Test

    Directory of Open Access Journals (Sweden)

    M.G. Bara Filho

    2008-01-01

    Full Text Available Strength and flexibility are common components of a training program and their maximal values are obtained through specific tests. However, little information about the damage effect of these training procedures in a skeletal muscle is known. Objective: To verify a serum CK changes 24 h after a sub maximal stretching routine and after the static flexibility and maximal strength tests. Methods: the sample was composed by 14 subjects (man and women, 28 ± 6 yr. physical education students. The volunteers were divided in a control group (CG and experimental group (EG that was submitted in a stretching routine (EG-ST, in a maximal flexibility static test (EG-FLEX and in 1-RM test (EG-1-RM, with one week interval among tests. The anthropometrics characteristics were obtained by digital scale with stadiometer (Filizola, São Paulo, Brasil, 2002. The blood samples were obtained using the IFCC method with reference values 26-155 U/L. The De Lorme and Watkins technique was used to access maximal maximal strength through bench press and leg press. The maximal flexibility test consisted in three 20 seconds sets until the point of maximal discomfort. The stretching was done in normal movement amplitude during 6 secons. Results: The basal and post 24 h CK values in CG and EG (ST; Flex and 1 RM were respectively 195,0 ± 129,5 vs. 202,1 ± 124,2; 213,3 ± 133,2 vs. 174,7 ± 115,8; 213,3 ± 133,2 vs. 226,6 ± 126,7 e 213,3 ± 133,2 vs. 275,9 ± 157,2. It was only observed a significant difference (p = 0,02 in the pre and post values inGE-1RM. Conclusion: only maximal strength dynamic exercise was capable to cause skeletal muscle damage.

  18. TEST-RETEST RELIABILITY OF HAND GRIP STRENGTH MEASUREMENT USING A JAMAR HAND DYNAMOMETER IN PATIENTS WITH ACUTE AND CHRONIC CERVICAL RADICULOPATHY

    Directory of Open Access Journals (Sweden)

    Ejazi G

    2017-12-01

    Full Text Available Background: To evaluate the test-retest reliability of Jamar hand held dynamometer for measuring handgrip strength (HGS in patients with acute and chronic cervical radiculopathy and to find out the difference in measurement of the handgrip strength between acute and chronic cervical radiculopathy. Methods: A prospective, observational and non-experimental, the comparative study design was used. A sample of 72 subjects (37 women and 35 men suffering from cervical radiculopathy were divided into two groups i.e., Group A(acute and Group B(chronic, handgrip strength was measured using Jamar hand held dynamometer on two occasions by the same rater with an interval of 7-days. Data collection was based on standard guidelines of American Society of Hand Therapists. Three gripping trials (measured in Kg with patient’s arm in standardized arm position were recorded. The data was analyzed from the mean score obtained from the sample. Result: One-way Analysis of Variance(ANOVA was used to evaluate test-retest reliability and Tukey-Kramer Multiple Comparison Test used to find the difference between handgrip strength among acute and chronic Cervical radiculopathy cases. Greater P-value (>0.05 in both testing session, as well as 95% of the confidence interval, shows the reliability of the instrument and lesser p-value (0.05 in female subjects shows no significant difference in handgrip strength between the two groups. Conclusion: Excellent test-retest reliability for hand grip strength measurement was measured in patients with acute and chronic cervical radiculopathy shows that the equipment could be used as an assessment tool for this patient and significant difference exists among male handgrip strength between acute and chronic cervical radiculopathy cases whereas no difference exists among female handgrip strength between acute and chronic cervical radiculopathy cases.

  19. Intrinsic rewards, fruit and vegetable consumption, and habit strength: a three-wave study testing the associative-cybernetic model.

    Science.gov (United States)

    Wiedemann, Amelie U; Gardner, Benjamin; Knoll, Nina; Burkert, Silke

    2014-03-01

    Habit formation is thought to lead to long-term maintenance of fruit and vegetable consumption. Habits develop through context-dependent repetition, but additional variables such as intrinsic reward of behaviour may influence habit strength. Drawing upon the Associative-Cybernetic Model, this exploratory study tested different pathways by which intrinsic reward may influence fruit and vegetable consumption habit strength. In a three-wave study of fruit and vegetable intake in adults (N = 127) from the general population, intrinsic reward, intention, and self-efficacy were assessed at baseline, fruit and vegetable consumption and intrinsic reward two weeks later, and habit strength another two weeks later. Direct, indirect, and moderation effects of intrinsic reward on habit strength were tested simultaneously in a moderated mediation model. Intrinsic reward had a positive indirect effect on habit strength through its influence on the frequency of fruit and vegetable consumption. Further, the relationship between fruit and vegetable consumption and habit was stronger where consumption was considered more intrinsically rewarding. Findings highlight the potential relevance of intrinsic reward to habit. We suggest that intrinsic rewards from behaviour may not only facilitate habit via behaviour frequency, but also reinforce the relationship between behavioural repetition and habit strength. © 2013 The International Association of Applied Psychology.

  20. Change of notch impact strength depending on radiation dose and test temperature

    Directory of Open Access Journals (Sweden)

    Martin Bednarik

    2017-01-01

    Full Text Available The main purpose of this paper has been determine the effect of radiation crosslinking on the notch impact strength of polyamides filled with fiberglass. These properties were examined in dependence on the dosage of the ionizing beta radiation (non-irradiated samples and those irradiated by dosage 66 and 132 kGy were compared and on the test temperature (23–150 °C.

  1. Grey Box Modelling of Hydrological Systems

    DEFF Research Database (Denmark)

    Thordarson, Fannar Ørn

    of two papers where the stochastic differential equation based model is used for sewer runoff from a drainage system. A simple model is used to describe a complex rainfall-runoff process in a catchment, but the stochastic part of the system is formulated to include the increasing uncertainty when...... rainwater flows through the system, as well as describe the lower limit of the uncertainty when the flow approaches zero. The first paper demonstrates in detail the grey box model and all related transformations required to obtain a feasible model for the sewer runoff. In the last paper this model is used......The main topic of the thesis is grey box modelling of hydrologic systems, as well as formulation and assessment of their embedded uncertainties. Grey box model is a combination of a white box model, a physically-based model that is traditionally formulated using deterministic ordinary differential...

  2. Hemoadsorption of high-mobility-group box 1 using a porous polymethylmethacrylate fiber in a swine acute liver failure model.

    Science.gov (United States)

    Amemiya, Ryusuke; Shinoda, Masahiro; Yamada, Masayuki; Ueno, Yoshiyuki; Shimada, Kaoru; Fujieda, Hiroaki; Yagi, Hiroshi; Mizota, Takamasa; Nishiyama, Ryo; Oshima, Go; Yamada, Shingo; Matsubara, Kentaro; Abe, Yuta; Hibi, Taizo; Kitago, Minoru; Obara, Hideaki; Itano, Osamu; Kitagawa, Yuko

    2018-04-01

    High-mobility-group box chromosomal protein 1 has been identified as an important mediator of various kinds of acute and chronic inflammation. In this study, we aimed to develop a column that effectively adsorbs high-mobility-group box chromosomal protein 1 by altering the pore size of the fiber. First, we produced three types of porous polymethylmethacrylate fiber by altering the concentration of polymethylmethacrylate dissolved in dimethylsulfoxide. We then selected a fiber based on the results of an in vitro incubation test of high-mobility-group box chromosomal protein 1 adsorption. Using the selected fiber, we constructed a new column and tested its high-mobility-group box chromosomal protein 1 adsorption capacity during 4-h extracorporeal hemoperfusion in a swine acute liver failure model. Electron microscope observation showed that the three types of fibers had different pore sizes on the surface and in cross section, which were dependent on the concentration of polymethylmethacrylate. In the in vitro incubation test, fiber with moderate-sized pores demonstrated the highest adsorption capacity. In the in vivo hemoperfusion study, the ratio of the high-mobility-group box chromosomal protein 1 concentration at the outlet versus the inlet of the column was significantly lower with the new column than with the control column during 4-h extracorporeal hemoperfusion. The normalized plasma level of high-mobility-group box chromosomal protein 1 at 12 h after the completion of hemoperfusion was significantly lower with the new column than with the control column. The newly developed polymethylmethacrylate column adsorbs high-mobility-group box chromosomal protein 1 during hemoperfusion in swine ALF model.

  3. Energetics demands and physiological responses to boxing match and subsequent recovery.

    Science.gov (United States)

    Nassib, Sabri; Hammoudi-Nassib, Sarra; Chtara, Mokhtar; Mkaouer, Bessem; Maaouia, Ghazwa; Bezrati-Benayed, Ikram; Chamari, Karim

    2017-01-01

    Determining the physiological profile of athletes in boxing match is important for defining aspects of physical performance that are important to competitive performance. Therefore, examination of the energy pathway of high-level boxers' athletes can be very helpful for optimizing training and then improving boxing physical fitness and performance. The aim of the present study was to assess the physiological and cardiovascular responses during boxing matches and subsequent recovery. Fifteen male international level boxers (mean age 19.56±3.6 years; mean body mass 72.46±11.86 kg; mean height 176.50±7.22 cm) participated in this study. Blood samples were drawn from the antecubital vein before and after the boxing matches (T1: pre-match rest measure around 11:00 a.m., T2: measure at 3 minutes of post-match recovery; T3: measure at 60 minutes of recovery; T4: measure at 24 hours post-match - the match started around 11:30 a.m.). An analysis of glucose, triglycerides, lactate, cholesterol, creatinine, uric-acid, high density lipoprotein, and low density lipoprotein concentrations was performed for each sample. Participants did perform a maximal incremental test to measure maximal heart rate (HRmax). Heart rate responses to the matches were measured and expressed in percentage of HRmax. The average HR recorded during the match corresponded to 93±3.26% of HRmax. The levels of glucose, lactate, and cholesterol increased significantly from T1 to T2. Likewise, creatinine levels increased significantly from T1 to T2 and T3. However, the cholesterol level decreased significantly at T3 in comparison with T1. Moreover, 24-hour post-match creatinine levels were significantly lower and triglyceride levels were significantly higher compared with T1. The main results of this study revealed that the boxing matches stress the lipid metabolism system during boxing and post-match (for at least 24 hours) even if it is widely recognized boxing being mainly composed of repeated short

  4. Experimental and simulated strength of spot welds

    DEFF Research Database (Denmark)

    Nielsen, Chris Valentin; Bennedbæk, Rune A.K.; Larsen, Morten B.

    2014-01-01

    Weld strength testing of single spots in DP600 steel is presented for the three typical testing procedures, i.e. tensile-shear, cross-tension and peel testing. Spot welds are performed at two sets of welding parameters and strength testing under these conditions is presented by load......-elongation curves revealing the maximum load and the elongation at break. Welding and strength testing is simulated by SORPAS® 3D, which allows the two processes to be prepared in a combined simulation, such that the simulated welding properties are naturally applied to the simulation of strength testing. Besides...... the size and shape of the weld nugget, these properties include the new strength of the material in the weld and the heat affected zone based on the predicted hardness resulting from microstructural phase changes simulated during cooling of the weld before strength testing. Comparisons between overall...

  5. Evaluation method for the deformation of channel box

    International Nuclear Information System (INIS)

    Sadaoka, Noriyuki; Kumahora, Hiroki; Miki, Kazuyoshi.

    1990-01-01

    In a BWR type nuclear reactor, a channel box undergoes creep deformation due to the effects of a pressure difference between inside and outside of the channel box and a reactor water temperature, which is accelerated by the irradiation of radiation rays and the extent of which depends on the loading position. Then, there are provided a step of determining the extent of the deformation of the channel box in a burning period in the past, a step of setting the loading position for the channel box in the reactor core, a step of forecasting the extent of the deformation of the channel box based on the data of reactor core characteristics, the date of the physical properties of the materials and the shape of the channel box, the data of the loading pattern of fuel assemblies and the extent of deformation, and a step of estimating whether the forecast deforming extent is within an allowable range or not. As a result, the deforming extent for each of the channel boxes can be forecast and, accordingly, the interference with the control rods can be estimated accurately. (N.H.)

  6. Fuel element box inspection device

    International Nuclear Information System (INIS)

    Ortmayer, R.M.; Pick, W.

    1985-01-01

    The invention concerns a device for inspecting the outer geometry of a long fuel element box by measuring the surface contours over its longitudinal crossection and along its length by sensors. These are kept in a sledge which can be moved along the fuel element guide in a slot guide. The measurement signals reach an evaluation device outside the longitudinal box. (orig./HP) [de

  7. Neurochemical aftermath of amateur boxing.

    Science.gov (United States)

    Zetterberg, Henrik; Hietala, M Albert; Jonsson, Michael; Andreasen, Niels; Styrud, Ewa; Karlsson, Ingvar; Edman, Ake; Popa, Cornel; Rasulzada, Abdullah; Wahlund, Lars-Olof; Mehta, Pankaj D; Rosengren, Lars; Blennow, Kaj; Wallin, Anders

    2006-09-01

    Little solid information is available on the possible risks for neuronal injury in amateur boxing. To determine whether amateur boxing and severity of hits are associated with elevated levels of biochemical markers for neuronal injury in cerebrospinal fluid. Longitudinal study. Referral center specializing in evaluation of neurodegenerative disorders. Fourteen amateur boxers (11 men and 3 women) and 10 healthy male nonathletic control subjects. The boxers underwent lumbar puncture 7 to 10 days and 3 months after a bout. The control subjects underwent LP once. Neurofilament light protein, total tau, glial fibrillary acidic protein, phosphorylated tau, and beta-amyloid protein 1-40 (Abeta([1-40])) and 1-42 (Abeta([1-42])) concentrations in cerebrospinal fluid were measured. Increased levels after a bout compared with after 3 months of rest from boxing were found for 2 markers for neuronal and axonal injury, neurofilament light protein (mean +/- SD, 845 +/- 1140 ng/L vs 208 +/- 108 ng/L; P = .008) and total tau (mean +/- SD, 449 +/- 176 ng/L vs 306 +/- 78 ng/L; P = .006), and for the astroglial injury marker glial fibrillary acidic protein (mean +/- SD, 541 +/- 199 ng/L vs 405 +/- 138 ng/L; P = .003). The increase was significantly higher among boxers who had received many hits (>15) or high-impact hits to the head compared with boxers who reported few hits. In the boxers, concentrations of neurofilament light protein and glial fibrillary acidic protein, but not total tau, were significantly elevated after a bout compared with the nonathletic control subjects. With the exception of neurofilament light protein, there were no significant differences between boxers after 3 months of rest from boxing and the nonathletic control subjects. Amateur boxing is associated with acute neuronal and astroglial injury. If verified in longitudinal studies with extensive follow-up regarding the clinical outcome, analyses of cerebrospinal fluid may provide a scientific basis for

  8. Evaluating resin-enamel bonds by microshear and microtensile bond strength tests: effects of composite resin

    Science.gov (United States)

    de ANDRADE, Andrea Mello; MOURA, Sandra Kiss; REIS, Alessandra; LOGUERCIO, Alessandro Dourado; GARCIA, Eugenio Jose; GRANDE, Rosa Helena Miranda

    2010-01-01

    Objectives The aims of this study were to evaluate the effect of resin composite (Filtek Z250 and Filtek Flow Z350) and adhesive system [(Solobond Plus, Futurabond NR (VOCO) and Adper Single Bond (3M ESPE)] on the microtensile (µTBS) and microshear bond strength (µSBS) tests on enamel, and to correlate the bond strength means between them. Material and methods Thirty-six extracted human molars were sectioned to obtain two tooth halves: one for µTBS and the other one for µSBS. Adhesive systems and resin composites were applied to the enamel ground surfaces and light-cured. After storage (37ºC/24 h) specimens were stressed (0.5 mm/ min). Fracture modes were analyzed under scanning electron microscopy. The data were analyzed using two-way ANOVA and Tukey's test (α=0.05). Results The correlation between tests was estimated with Pearson's product-moment correlation statistics (α =0.05). For both tests only the main factor resin composite was statistically significant (padhesives. Both microbond tests seem to be positive and linearly correlated and can therefore lead to similar conclusions. PMID:21308290

  9. New proposal of moderator temperature coefficient estimation method using gray-box model in NPP, (1)

    International Nuclear Information System (INIS)

    Mori, Michitsugu; Kagami, Yuichi; Kanemoto, Shigeru; Enomoto, Mitsuhiro; Tamaoki, Tetsuo; Kawamura, Shinichiro

    2004-01-01

    The purpose of the present paper is to establish a new void reactivity coefficient (VRC) estimation method based on gray box modeling concept. The gray box model consists of a point kinetics model as the first principle model and a fitting model of moderator temperature kinetics. Applying Kalman filter and maximum likehood estimation algorithms to the gray box model, MTC can be estimated. The verification test is done by Monte Carlo simulation, and, it is shown that the present method gives the best estimation results comparing with the conventional methods from the viewpoints of non-biased and smallest scattering estimation performance. Furthermore, the method is verified via real plant data analysis. The reason of good performance of the present method is explained by proper definition of likelihood function based on explicit expression of observation and system noise in the gray box model. (author)

  10. Do the Microshear Test Variables Affect the Bond Strength Values?

    Directory of Open Access Journals (Sweden)

    Andrea M. Andrade

    2012-01-01

    Full Text Available Little is known about the effect of specimen preparation and testing protocols on the micro-shear bond strength (μSBS results. To evaluate whether variations in polyethylene rod use affect (μSBS. Human dentin disks were randomly distributed into six groups (: polyethylene tube (3 levels and adhesive system (2 levels. In Group 1, polyethylene tubes filled with polymerized composite were placed on adhesive covered surfaces. Tubes were removed 24 h after water storage, leaving the rods only. In Group 2, the same procedure was performed; however, tubes were kept in place during testing. In Group 3, composite rods without tubes were placed on adhesive covered dentin. In all groups, adhesives were photoactivated after positioning filled tubes/rods on adhesive covered surfaces. Specimens were tested under shear mode and the data subjected to a two-way ANOVA and Tukey’s tests. Groups 1 and 2 resulted in statistically similar mean μSBS (; however, a greater number of pretest failures were observed for Group 1. Higher μSBS values were detected for Group 3, irrespective of adhesive system used (. Removing the polyethylene tube before composite rod is placed on dentin affects μSBS values.

  11. OECD MCCI Small-Scale Water Ingression and Crust Strength tests (SSWICS) design report, Rev. 2 October 31, 2002

    International Nuclear Information System (INIS)

    Farmer, M.; Lomperski, S.; Kilsdonk, D.; Aeschlimann, B.; Pfeiffer, P.

    2011-01-01

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure and (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are planned to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium (∼φ30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. A description of the test apparatus, instrumentation, data reduction, and test matrix are the subject of the first portion of this report. The issue of crust strength will be addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus will measure the fracture strength of the crust while under a thermal load created by a heating element beneath the crust. The introduction of a thermal gradient across the crust is thought to be important for these tests because of uncertainty in the magnitude of the thermal stresses and thus their relative

  12. OECD MCCI Small-Scale Water Ingression and Crust Strength Tests (SSWICS) SSWICS-3 test data report: thermal Hydraulic results, Rev. 0 February 19, 2003

    International Nuclear Information System (INIS)

    Lomperski, S.; Farmer, M.T.; Kilsdonk, D.; Aeschlimann, B.

    2011-01-01

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure and (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are being conducted to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium (∼φ30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. The issue of crust strength will be addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus will measure the fracture strength of the crust while under a thermal load created by a heating element beneath the crust. The two apparatuses used to measure the melt quench rate and crust strength are jointly referred to as SSWICS (Small-Scale Water Ingression and Crust Strength). This report describes results of the third water ingression test, designated SSWICS-3. This test investigated the quenching behavior of a fully oxidized PWR

  13. 30 CFR 18.49 - Connection boxes on machines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Connection boxes on machines. 18.49 Section 18..., AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.49 Connection boxes on machines. Connection boxes used to facilitate replacement...

  14. VO₂ requirements of boxing exercises.

    Science.gov (United States)

    Arseneau, Eric; Mekary, Saïd; Léger, Luc A

    2011-02-01

    The purpose of this study was to quantify the physiological requirements of various boxing exercises such as sparring, pad work, and punching bag. Because it was not possible to measure the oxygen uptake (VO₂) of "true" sparring with a collecting gas valve in the face, we developed and validated a method to measure VO₂ of "true" sparring based on "postexercise" measurements. Nine experienced male amateur boxers (Mean ± SD: age = 22.0 ± 3.5 years, height = 176.0 ± 8.0 cm, weight = 71.4 ± 10.9 kg, number of fights = 13.0 ± 9.5) of regional and provincial level volunteered to participate in 3 testing sessions: (a) maximal treadmill test in the LAB, (b) standardized boxing training in the GYM, and (c) standardized boxing exercises in the LAB. Measures of VO₂, heart rate (HR), blood lactate concentration [LA], rated perceived exertion level, and punching frequencies were collected. VO₂ values of 43.4 ± 5.9, 41.1 ± 5.1, 24.7 ± 6.1, 30.4 ± 5.8, and 38.3 ± 6.5 ml·kg⁻¹·min⁻¹ were obtained, which represent 69.7 ± 8.0, 66.1 ± 8.0, 39.8 ± 10.4, 48.8 ± 8.5, and 61.7 ± 10.3%VO₂peak for sparring, pad work, and punching bag at 60, 120, and 180 b·min⁻¹, respectively. Except for lower VO₂ values for punching the bag at 60 and 120 b·min⁻¹ (p < 0.05), there was no VO₂ difference between exercises. Similar pattern was obtained for %HRmax with respective values of 85.5 ± 5.9, 83.6 ± 6.3, 67.5 ± 3.5, 74.8 ± 5.9, and 83.0 ± 6.0. Finally, sparring %HRmax and [LA] were slightly higher in the GYM (91.7 ± 4.3 and 9.4 ± 2.2 mmol·L⁻¹) vs. LAB (85.5 ± 5.9 and 6.1 ± 2.3 mmol·L⁻¹). Thus, in this study simulated LAB sparring and pad work required similar VO₂ (43-41 ml·kg⁻¹·min⁻¹, respectively), which corresponds to ~70%VO₂peak. These results underline the importance of a minimum of aerobic fitness for boxers and draw some guidelines for the intensity of training.

  15. 49 CFR 178.513 - Standards for boxes of natural wood.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Standards for boxes of natural wood. 178.513... natural wood. (a) The following are the identification codes for boxes of natural wood: (1) 4C1 for an ordinary box; and (2) 4C2 for a box with sift-proof walls. (b) Construction requirements for boxes of...

  16. Opening Pandora's Box: The impact of open system modeling on interpretations of anoxia

    Science.gov (United States)

    Hotinski, Roberta M.; Kump, Lee R.; Najjar, Raymond G.

    2000-06-01

    The geologic record preserves evidence that vast regions of ancient oceans were once anoxic, with oxygen levels too low to sustain animal life. Because anoxic conditions have been postulated to foster deposition of petroleum source rocks and have been implicated as a kill mechanism in extinction events, the genesis of such anoxia has been an area of intense study. Most previous models of ocean oxygen cycling proposed, however, have either been qualitative or used closed-system approaches. We reexamine the question of anoxia in open-system box models in order to test the applicability of closed-system results over long timescales and find that open and closed-system modeling results may differ significantly on both short and long timescales. We also compare a scenario with basinwide diffuse upwelling (a three-box model) to a model with upwelling concentrated in the Southern Ocean (a four-box model). While a three-box modeling approach shows that only changes in high-latitude convective mixing rate and character of deepwater sources are likely to cause anoxia, four-box model experiments indicate that slowing of thermohaline circulation, a reduction in wind-driven upwelling, and changes in high-latitude export production may also cause dysoxia or anoxia in part of the deep ocean on long timescales. These results suggest that box models must capture the open-system and vertically stratified nature of the ocean to allow meaningful interpretations of long-lived episodes of anoxia.

  17. Ultimate shearing strength of aseismatic walls with many small holes for reactor buildings

    International Nuclear Information System (INIS)

    Yoshizaki, Seiji; Ezaki, Tetsuro; Korenaga, Takeyoshi; Sotomura, Kentaro.

    1984-01-01

    The aseismatic walls for reactor buildings have complicated forms, and are characterized by large wall thickness and high reinforcement ratio as compared with ordinary aseismatic walls. The forms are mainly box, cylinder or irregular polygonal prism and their combination. The design of the walls with many small holes has been performed on the basis of the reinforced concrete structure calculation standard of the Architectural Institute of Japan, following the case with large opening. When there are many small holes, the arrangement of reinforcement for the openings becomes complex, and the construction is difficult. It is necessary to rationalize the design and to simplify the reinforcement work. Under the background like this, the experiment to examine the shearing property in bending of the aseismatic walls with many small holes for reactor buildings was carried out, and horizontal loading test was performed on 43 specimens. The method of calculating the ultimate shearing strength of a wall without opening was proposed, and the method of applying it to a wall with many small holes is shown. The experimental method and the results, the examination of the experimental results, and the ultimate shearing strength of the aseismatic walls are reported. (Kako, I.)

  18. Reliability of Strength Testing using the Advanced Resistive Exercise Device and Free Weights

    Science.gov (United States)

    English, Kirk L.; Loehr, James A.; Laughlin, Mitzi A.; Lee, Stuart M. C.; Hagan, R. Donald

    2008-01-01

    The Advanced Resistive Exercise Device (ARED) was developed for use on the International Space Station as a countermeasure against muscle atrophy and decreased strength. This investigation examined the reliability of one-repetition maximum (1RM) strength testing using ARED and traditional free weight (FW) exercise. Methods: Six males (180.8 +/- 4.3 cm, 83.6 +/- 6.4 kg, 36 +/- 8 y, mean +/- SD) who had not engaged in resistive exercise for at least six months volunteered to participate in this project. Subjects completed four 1RM testing sessions each for FW and ARED (eight total sessions) using a balanced, randomized, crossover design. All testing using one device was completed before progressing to the other. During each session, 1RM was measured for the squat, heel raise, and deadlift exercises. Generalizability (G) and intraclass correlation coefficients (ICC) were calculated for each exercise on each device and were used to predict the number of sessions needed to obtain a reliable 1RM measurement (G . 0.90). Interclass reliability coefficients and Pearson's correlation coefficients (R) also were calculated for the highest 1RM value (1RM9sub peak)) obtained for each exercise on each device to quantify 1RM relationships between devices.

  19. Investigating the impact of non-linear geometrical effects on wind turbine blades—Part 1: Current status of design and test methods and future challenges in design optimization

    DEFF Research Database (Denmark)

    Jensen, Find Mølholt; Puri, Amit S.; Dear, John P.

    2011-01-01

    This article is the first part of a three-article series and it deals with full-scale tests of a load-carrying box girder. The two other articles present more details on smaller sub-component levels as well as cap specimens (article 2) and shear webs (article 3). This article also links to the two...... may also have a significant impact on present wind turbine blades. In this article, a 34 m long load-carrying box girder has been tested in static flap-wise bending, and it has been demonstrated that, for this design, the Brazier effect is a critical phenomenon of great relevance for the ultimate...... failure strength. The box girder has been evaluated with and without a cap (wire) reinforcement. The cap reinforcement is one out of seven inventions Risø DTU published in 2008, which are all intended to result in a lighter and more reliable blade design. Copyright © 2010 John Wiley & Sons, Ltd....

  20. Box Plots in the Australian Curriculum

    Science.gov (United States)

    Watson, Jane M.

    2012-01-01

    This article compares the definition of "box plot" as used in the "Australian Curriculum: Mathematics" with other definitions used in the education community; describes the difficulties students experience when dealing with box plots; and discusses the elaboration that is necessary to enable teachers to develop the knowledge…

  1. Construction and properties of Box-Behnken designs

    OpenAIRE

    Jo, Jinnam

    1992-01-01

    Box-Behnken designs are used to estimate parameters in a second-order response surface model (Box and Behnken, 1960). These designs are formed by combining ideas from incomplete block designs (BIBD or PBIBD) and factorial experiments, specifically 2k full or 2k-1 fractional factorials. In this dissertation, a more general mathematical formulation of the Box-Behnken method is provided, a general expression for the coefficient matrix in the least squares analysis for estimatin...

  2. ArduiPod Box: a low-cost and open-source Skinner box using an iPod Touch and an Arduino microcontroller.

    Science.gov (United States)

    Pineño, Oskar

    2014-03-01

    This article introduces the ArduiPod Box, an open-source device built using two main components (i.e., an iPod Touch and an Arduino microcontroller), developed as a low-cost alternative to the standard operant conditioning chamber, or "Skinner box." Because of its affordability, the ArduiPod Box provides an opportunity for educational institutions with small budgets seeking to set up animal laboratories for research and instructional purposes. A pilot experiment is also presented, which shows that the ArduiPod Box, in spite of its extraordinary simplicity, can be effectively used to study animal learning and behavior.

  3. Designing key-dependent chaotic S-box with larger key space

    International Nuclear Information System (INIS)

    Yin Ruming; Yuan Jian; Wang Jian; Shan Xiuming; Wang Xiqin

    2009-01-01

    The construction of cryptographically strong substitution boxes (S-boxes) is an important concern in designing secure cryptosystems. The key-dependent S-boxes designed using chaotic maps have received increasing attention in recent years. However, the key space of such S-boxes does not seem to be sufficiently large due to the limited parameter range of discretized chaotic maps. In this paper, we propose a new key-dependent S-box based on the iteration of continuous chaotic maps. We explore the continuous-valued state space of chaotic systems, and devise the discrete mapping between the input and the output of the S-box. A key-dependent S-box is constructed with the logistic map in this paper. We show that its key space could be much larger than the current key-dependent chaotic S-boxes.

  4. Muscle Strength Is a Poor Screening Test for Predicting Lower Extremity Injuries in Professional Male Soccer Players: A 2-Year Prospective Cohort Study.

    Science.gov (United States)

    Bakken, Arnhild; Targett, Stephen; Bere, Tone; Eirale, Cristiano; Farooq, Abdulaziz; Mosler, Andrea B; Tol, Johannes L; Whiteley, Rod; Khan, Karim M; Bahr, Roald

    2018-03-01

    Lower extremity muscle strength tests are commonly used to screen for injury risk in professional soccer. However, there is limited evidence on the ability of such tests in predicting future injuries. To examine the association between hip and thigh muscle strength and the risk of lower extremity injuries in professional male soccer players. Case-control study; Level of evidence, 3. Professional male soccer players from 14 teams in Qatar underwent a comprehensive strength assessment at the beginning of the 2013/2014 and 2014/2015 seasons. Testing consisted of concentric and eccentric quadriceps and hamstring isokinetic peak torques, eccentric hip adduction and abduction forces, and bilateral isometric adductor force (squeeze test at 45°). Time-loss injuries and exposure in training and matches were registered prospectively by club medical staff throughout each season. Univariate and multivariate Cox regression analyses were used to calculate hazard ratios (HRs) with 95% CIs. In total, 369 players completed all strength tests and had registered injury and exposure data. Of these, 206 players (55.8%) suffered 538 lower extremity injuries during the 2 seasons; acute muscle injuries were the most frequent. Of the 20 strength measures examined, greater quadriceps concentric peak torque at 300 deg/s (HR, 1.005 [95% CI, 1.00-1.01]; P = .037) was the only strength measure identified as significantly associated with a risk of lower extremity injuries in multivariate analysis. Greater quadriceps concentric peak torque at 60 deg/s (HR, 1.004 [95% CI, 1.00-1.01]; P = .026) was associated with the risk of overuse injuries, and greater bilateral adductor strength adjusted for body weight (HR, 0.75 [95% CI, 0.57-0.97; P = .032) was associated with a lower risk for any knee injury. Receiver operating characteristic curve analyses indicated poor predictive ability of the significant strength variables (area under the curve, 0.45-0.56). There was a weak association with the risk of

  5. Beads task vs. box task: The specificity of the jumping to conclusions bias.

    Science.gov (United States)

    Balzan, Ryan P; Ephraums, Rachel; Delfabbro, Paul; Andreou, Christina

    2017-09-01

    Previous research involving the probabilistic reasoning 'beads task' has consistently demonstrated a jumping-to-conclusions (JTC) bias, where individuals with delusions make decisions based on limited evidence. However, recent studies have suggested that miscomprehension may be confounding the beads task. The current study aimed to test the conventional beads task against a conceptually simpler probabilistic reasoning "box task" METHODS: One hundred non-clinical participants completed both the beads task and the box task, and the Peters et al. Delusions Inventory (PDI) to assess for delusion-proneness. The number of 'draws to decision' was assessed for both tasks. Additionally, the total amount of on-screen evidence was manipulated for the box task, and two new box task measures were assessed (i.e., 'proportion of evidence requested' and 'deviation from optimal solution'). Despite being conceptually similar, the two tasks did not correlate, and participants requested significantly less information on the beads task relative to the box task. High-delusion-prone participants did not demonstrate hastier decisions on either task; in fact, for box task, this group was observed to be significantly more conservative than low-delusion-prone group. Neither task was incentivized; results need replication with a clinical sample. Participants, and particularly those identified as high-delusion-prone, displayed a more conservative style of responding on the novel box task, relative to the beads task. The two tasks, whilst conceptually similar, appear to be tapping different cognitive processes. The implications of these results are discussed in relation to the JTC bias and the theoretical mechanisms thought to underlie it. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Design of strong wooden box coated with fiberglass reinforced resin for shipping and burial of contaminated glove boxes. Final report

    International Nuclear Information System (INIS)

    1982-01-01

    The project scope of work included the complete decontamination and decommissioning (D and D) of the Westinghouse ARD Fuel Laboratories at the Cheswick Site in the shortest possible time. This has been accomplished in the following four phases: (1) preparation of documents and necessary paperwork; packaging and shipping of all special nuclear materials in an acceptable form to a reprocessing agency; (2) decontamination of all facilities, glove boxes and equipment; loading of generated waste into bins, barrels and strong wooden boxes; (3) shipping of al bins, barrels and boxes containing waste to the designated burial site; removal of all utility services from the laboratories; and (4) final survey of remaining facilities and certification for nonrestricted use; preparation of final report. This attachment contains design of strong wooden box coated with fiberglass reinforced resin for shipping and burial of contaminated glove boxes

  7. Heart rate response during a simulated Olympic boxing match is predominantly above ventilatory threshold 2: a cross sectional study.

    Science.gov (United States)

    de Lira, Claudio Andre Barbosa; Peixinho-Pena, Luiz Fernando; Vancini, Rodrigo Luiz; de Freitas Guina Fachina, Rafael Júlio; de Almeida, Alexandre Aparecido; Andrade, Marília Dos Santos; da Silva, Antonio Carlos

    2013-01-01

    The present study aimed to describe heart rate (HR) responses during a simulated Olympic boxing match and examine physiological parameters of boxing athletes. Ten highly trained Olympic boxing athletes (six men and four women) performed a maximal graded exercise test on a motorized treadmill to determine maximal oxygen uptake (52.2 mL · kg(-1) · min(-1) ± 7.2 mL · kg(-1) · min(-1)) and ventilatory thresholds 1 and 2. Ventilatory thresholds 1 and 2 were used to classify the intensity of exercise based on respective HR during a boxing match. In addition, oxygen uptake (V̇O2) was estimated during the match based on the HR response and the HR-V̇O2 relationship obtained from a maximal graded exercise test for each participant. On a separate day, participants performed a boxing match lasting three rounds, 2 minutes each, with a 1-minute recovery period between each round, during which HR was measured. In this context, HR and V̇O2 were above ventilatory threshold 2 during 219.8 seconds ± 67.4 seconds. There was an increase in HR and V̇O2 as a function of round (round 3 boxing practitioners and other athletes.

  8. Light Therapy Boxes for Seasonal Affective Disorder

    Science.gov (United States)

    Seasonal affective disorder treatment: Choosing a light therapy box Light therapy boxes can offer an effective treatment for seasonal affective disorder. Features such as light intensity, safety, cost and ...

  9. Implementation of T-box/T/sup -1/-box based AES design on latest xilinx fpga

    International Nuclear Information System (INIS)

    Kundi, D.E.; Aziz, A.

    2015-01-01

    This work presents an efficient implementation of the AES (Advance Encryption Standard) based on Tbox/T-1-box design for both the encryption and decryption on FPGA (Field Programmable Gate Array). The proposed architecture not only make efficient use of full capacity of dedicated 32 Kb BRAM (Block RAM) of latest Xilinx FPGAs (Virtex-5, Virtex-6 and 7 Series) but also saves considerable amount of BRAM and logical resources by using multiple accesses from single BRAM in one cycle of system clock as compared to conventional LUT (Look-Up-Table) techniques. The proposed T-box/T-1-box based AES design for both the encryption and decryption fits into just 4 BRAMs on FPGA and results in good efficiency TPS (Throughput per Slice) with less power consumption. (author)

  10. Hydrogen atom within spherical boxes with penetrable walls

    International Nuclear Information System (INIS)

    Ley-Koo, E.; Rubinstein, S.

    1979-01-01

    We study a model for the hydrogen atom confined within spherical boxes with penetrable walls. The potential consists of the Coulomb potential inside the box and a constant potential outside the box; the Schroedinger equation admits analytical solutions in both regions. The energy eigenvalues and eigenfunctions for the lowest states of the system are determined numerically for boxes of different sizes and penetrabilities. In addition, we also evaluate the hyperfine splitting, nuclear magnetic shielding, polarizability and pressure of the system and investigate the effect of the confinement on these atomic properties

  11. A novel heuristic method for obtaining S-boxes

    International Nuclear Information System (INIS)

    Chen Guo

    2008-01-01

    An efficient algorithm named chaotic multi-swapping and simulated annealing (CMSSA) for obtaining cryptographically strong 8 x 8 S-boxes is presented. The method is based on chaotic maps and simulated annealing. In addition, cryptographic properties such as bijectivity, strict avalanche criterion, nonlinearity, output bits independence criterion and equiprobable input/output XOR distribution are analyzed in detail for the S-box produced. The results of numerical analysis show that the box has nearly fulfilled the criteria for a cryptographically strong S-box and can effectively resist several attacks

  12. Electrical requirements for unshielded glove boxes

    International Nuclear Information System (INIS)

    1978-02-01

    The specification relates to the general design and installation of electrical services required in unshielded glove boxes in which atmospheres of air, argon or nitrogen etc. may exist either temporarily or permanently. The specification does not apply to electrical services for glove boxes with flammable explosive atmospheres. (author)

  13. Boxing Injuries from an Instructional Program.

    Science.gov (United States)

    Welch, Michael J.; And Others

    1986-01-01

    This paper describes the safeguards as well as the injury pattern of the boxing program at the US Military Academy at West Point from 1983 to 1985. About 2,100 cadets received boxing instruction during this period with an injury rate of less than four percent. (Author/MT)

  14. Test-Retest Reliability of Handgrip Strength as an Outcome Measure in Patients With Symptoms of Shoulder Impingement Syndrome.

    Science.gov (United States)

    Savva, Christos; Mougiaris, Paraskevas; Xadjimichael, Christoforos; Karagiannis, Christos; Efstathiou, Michalis

    The purpose of this study was to investigate the degree of test-retest reliability of grip strength measurement using a hand dynamometer in patients with shoulder impingement syndrome. A total of 19 patients (10 women and 9 men; mean ± standard deviation age, 33.2 ± 12.9 years; range 18-59 years) with shoulder impingement syndrome were measured using a hand dynamometer by the same data collector in 2 different testing sessions with a 7-day interval. During each session, patients were encouraged to exert 3 maximal isometric contractions on the affected hand and the mean value of the 3 efforts (measured in kilogram-force [Kgf]) was used for data analysis. The intraclass correlation coefficient (ICC 2,1 ) as well as the standard error of measurement (SEM) and Bland-Altman plot were used to estimate the degree of test-retest reliability and the measurement error, respectively. Grip strength data analysis revealed an ICC 2,1 score of 0.94, which, based on the Shrout classification, is considered as excellent test-retest reliability of grip strength measurement. The small values of SEMs reported in both sessions (SEM 1 , 2.55 Kgf; SEM 2 , 2.39 Kgf) and the small width of the 95% limits of agreement in the Bland-Altman plot (ranging from -7.39 Kgf to 7.03 Kgf) reflected the measurement precision and the narrow variation of the differences during the 2 testing sessions. Results from this study identified excellent test-retest reliability of grip strength measurement in shoulder impingement syndrome, indicating its potential use as an outcome measure in clinical practice. Copyright © 2018. Published by Elsevier Inc.

  15. AstroBox2 – Detector for low-energy β-delayed particle detection

    Energy Technology Data Exchange (ETDEWEB)

    Saastamoinen, A., E-mail: ajsaasta@comp.tamu.edu [Cyclotron Institute, Texas A& M University, College Station, TX 77843 (United States); Pollacco, E. [IRFU, CEA Saclay, Gif-sur-Yvette (France); Roeder, B.T.; Spiridon, A.; Daq, M. [Cyclotron Institute, Texas A& M University, College Station, TX 77843 (United States); Trache, L.; Pascovici, G. [National Institute of Physics and Nuclear Engineering, Bucharest-Magurele RO-077125 (Romania); De Oliveira, R. [CERN, Geneva (Switzerland); Rodrigues, M.R.D. [Instituto de Física, Universidade de São Paulo, Caixa Postal 66318, CEP 05314-970, São Paulo, SP (Brazil); Tribble, R.E. [Cyclotron Institute, Texas A& M University, College Station, TX 77843 (United States)

    2016-06-01

    Efficient suppression of β-background is essential for studies of low-energy β-delayed charged particle decays of astrophysical interest. A promising method for such studies has been a micro pattern gas amplifier detector where the sample is implanted into the gas volume and the decays that follow are observed with high gain and signal to noise ratio. An upgraded version of the original AstroBox detector has been built and commissioned at Texas A&M University. Here a description of the new AstroBox2 detector is given, selected results from the commissioning tests are presented, and future perspectives discussed.

  16. Prohibiting Headgear for Safety in Amateur Boxing? Opinion of the Canadian Boxing Community: an Online Poll.

    Science.gov (United States)

    Dickinson, Philip; Rempel, Philip

    In 2013, the Amateur International Boxing Association (AIBA) introduced a rule banning headgear for male-senior open class boxers during competition. The AIBA has defended the rule change as motivated by safety and supported by internal unpublished studies. As a result, in 2018, the AIBA plans to universally prohibit headgear in competition: for all competitors (male and female), all ages and all levels. Within Canada, this ruling has generated controversy in the boxing community, yet there has been no overall measure of opinion. To address this, we instituted a voluntary, anonymous, online open-access poll to allow members of the boxing community to express their stance on headgear use in competition. In total, 636 responses were received. A total of 71.5 % of Canadian respondents believed headgear should be mandatory at all levels. Only 5.8 % agreed that headgear should be prohibited, as planned for 2018. Estimating results on a representative breakdown of boxing membership in Canada, a similar pattern emerged, whereby 68.2 % concurred with mandatory headgear while only 4.95 % supported its prohibition. Parents of boxers were almost unanimously against banning headgear, stating they would change sports as a result. Similarly, only 1.7 % of women believed headgear should be prohibited. The consensus of the Canadian boxing community largely opposes the rule changes that the AIBA has implemented. The results highlight risks posed to the long-term viability of the sport, if significant grassroots safety concerns are disregarded.

  17. Isometric shoulder strength in young swimmers.

    Science.gov (United States)

    McLaine, Sally J; Ginn, Karen A; Fell, James W; Bird, Marie-Louise

    2018-01-01

    The prevalence of shoulder pain in young swimmers is high. Shoulder rotation strength and the ratio of internal to external rotation strength have been reported as potential modifiable risk factors associated with shoulder pain. However, relative strength measures in elevated positions, which include flexion and extension, have not been established for the young swimmer. The aim of this study was to establish clinically useful, normative shoulder strength measures and ratios for swimmers (14-20 years) without shoulder pain. Cross-sectional, observational study. Swimmers (N=85) without a recent history of shoulder pain underwent strength testing of shoulder flexion and extension (in 140° abduction); and internal and external rotation (in 90° abduction). Strength tests were performed in supine using a hand-held dynamometer and values normalised to body weight. Descriptive statistics were calculated for strength and strength ratios (flexion:extension and internal:external rotation). Differences between groups (based on gender, history of pain, test and arm dominance) were explored using independent and paired t tests. Normative shoulder strength values and ratios were established for young swimmers. There was a significant difference (pdifferences in strength ratios. Relative strength of the dominant and non-dominant shoulders (except for extension); and for swimmers with and without a history of shoulder pain was not significantly different. A normal shoulder strength profile for the young swimmer has been established which provides a valuable reference for the clinician assessing shoulder strength in this population. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  18. 47 CFR 90.241 - Radio call box operations.

    Science.gov (United States)

    2010-10-01

    ... remains on for a period in excess of three minutes. The automatic cutoff system must be designed so the... Public Safety Pool for highway call box systems subject to the following requirements: (1) Call box... effective radiated power (ERP). (3) The height of a call box antenna may not exceed 6.1 meters (20 feet...

  19. Improved methods for testing bond and intrinsic strength and fatigue of thermally sprayed metallic and ceramic coatings

    International Nuclear Information System (INIS)

    Schweitzer, K.K.; Ziehl, M.H.; Schwaminger, C.

    1991-01-01

    Conventional bond strength tests for thermally sprayed coatings represent only a rough means of obtaining overall strength values, with no differentiation between adhesion at the interface and intrinsic coating properties. In order to obtain information about the influence of substrate surface preparation on the adhesion of a Tribaloy T700 coating, tensile bond strength and modified crack-opening displacement (COD) specimens were tested by deliberate crack initiation at the interface. Crack initiation was achieved by weakening of the interface at the outer diameter in the case of bond strength specimens or at the notch root in the case of COD specimens. This made it possible to look at the influence of surface roughness and grit contamination on the coating adhesion separately. Modified COD specimens with the notch in the centre of the coating were used to determine crack-opening energies and critical stress intensity factors of atmospheric plasma-sprayed NiAl and low pressure plasma-sprayed CoNiCrAlY bond coatings and a ZrO 2 7Y 2 O 3 thermal barrier coating (TBC). Additionally, bond strength specimens were stressed dynamically, and it could be demonstrated that Woehler (S/N) diagrams can be established for a metallic NiAl bond coating and even for a ceramic ZrO 2 7Y 2 O 3 TBC. (orig.)

  20. Evaluating resin-enamel bonds by microshear and microtensile bond strength tests: effects of composite resin

    Directory of Open Access Journals (Sweden)

    Andrea Mello de Andrade

    2010-12-01

    Full Text Available OBJECTIVES: The aims of this study were to evaluate the effect of resin composite (Filtek Z250 and Filtek Flow Z350 and adhesive system [(Solobond Plus, Futurabond NR (VOCO and Adper Single Bond (3M ESPE] on the microtensile (μTBS and microshear bond strength (μSBS tests on enamel, and to correlate the bond strength means between them. MATERIAL AND METHODS: Thirty-six extracted human molars were sectioned to obtain two tooth halves: one for μTBS and the other one for μSBS. Adhesive systems and resin composites were applied to the enamel ground surfaces and light-cured. After storage (37(0C/24 h specimens were stressed (0.5 mm/min. Fracture modes were analyzed under scanning electron microscopy. The data were analyzed using two-way ANOVA and Tukey's test (α=0.05. RESULTS: The correlation between tests was estimated with Pearson's product-moment correlation statistics (α =0.05. For both tests only the main factor resin composite was statistically significant (p<0.05. The correlation test detected a positive (r=0.91 and significant (p=0.01 correlation between the tests. CONCLUSIONS: The results were more influenced by the resin type than by the adhesives. Both microbond tests seem to be positive and linearly correlated and can therefore lead to similar conclusions.