WorldWideScience

Sample records for strength testing 10-m

  1. Adductor Canal Block With 10 mL Versus 30 mL Local Anesthetics and Quadriceps Strength

    DEFF Research Database (Denmark)

    Jæger, Pia; Koscielniak-Nielsen, Zbigniew J; Hilsted, Karen Lisa

    2015-01-01

    weakness. METHODS: We performed a paired, blinded, randomized trial including healthy men. All subjects received bilateral ACBs with ropivacaine 0.1%; 10 mL in 1 leg and 30 mL in the other leg. The primary outcome was the difference in number of subjects with quadriceps strength reduced by more than 25...... of the predefined time points or in sensory block. The only statistically significant difference between volumes was found in the 30-Second Chair Stand Test at 2 hours (P = 0.02), but this difference had disappeared at 4 hours (P = 0.06). CONCLUSIONS: Varying the volume of ropivacaine 0.1% used for ACB between 10...

  2. Criterion-Related Validity of a Simple Muscle Strength Test to Assess Whole Body Muscle Strength in Chinese Children Aged 10 to 12 Years.

    Science.gov (United States)

    Yin, Liqin; Tang, Changfa; Tao, Xia

    2018-01-01

    To study the criterion-related validity of simple muscle strength test (SMST) indicators and assess whole body muscle strength in Chinese children aged 10 to 12 years old. Two hundred and forty children were equally divided into four groups in different genders and residences. The SMST indicators (hand-grip, knee bent push-up, back muscle strength, sit-up, leg muscle strength, and standing long jump) were tested. We set up the total level of the whole-body muscle strength ( F total ) through testing isokinetic muscle strength of the six joints' flexion and extension movements. Pearson correlation analyses were used to analyze the correlation between the SMST indicators and the F total . (1) Leg muscle strength and back muscle strength demonstrated the highest validity scores. Sit-ups, hand grip, and standing long jump demonstrated the lowest validity scores. (2) Leg muscle strength had the highest validity for males, but back muscle strength had the highest validity for females. Back muscle strength and leg muscle strength can give the highest validity of assessing whole body muscle strength, and also has higher validity in both the urban and rural children. For urban children, but not rural, the knee bent push-up also has a high validity indicator.

  3. Criterion-Related Validity of a Simple Muscle Strength Test to Assess Whole Body Muscle Strength in Chinese Children Aged 10 to 12 Years

    Directory of Open Access Journals (Sweden)

    Liqin Yin

    2018-01-01

    Full Text Available Objective. To study the criterion-related validity of simple muscle strength test (SMST indicators and assess whole body muscle strength in Chinese children aged 10 to 12 years old. Methods. Two hundred and forty children were equally divided into four groups in different genders and residences. The SMST indicators (hand-grip, knee bent push-up, back muscle strength, sit-up, leg muscle strength, and standing long jump were tested. We set up the total level of the whole-body muscle strength (Ftotal through testing isokinetic muscle strength of the six joints’ flexion and extension movements. Pearson correlation analyses were used to analyze the correlation between the SMST indicators and the Ftotal. Results. (1 Leg muscle strength and back muscle strength demonstrated the highest validity scores. Sit-ups, hand grip, and standing long jump demonstrated the lowest validity scores. (2 Leg muscle strength had the highest validity for males, but back muscle strength had the highest validity for females. Conclusions. Back muscle strength and leg muscle strength can give the highest validity of assessing whole body muscle strength, and also has higher validity in both the urban and rural children. For urban children, but not rural, the knee bent push-up also has a high validity indicator.

  4. Surface magnetic field strengths: New tests of magnetoconvective models of M dwarfs

    International Nuclear Information System (INIS)

    MacDonald, James; Mullan, D. J.

    2014-01-01

    Precision modeling of M dwarfs has become worthwhile in recent years due to the increasingly precise values of masses and radii which can be obtained from eclipsing binary studies. In a recent paper, Torres has identified four prime M dwarf pairs with the most precise empirical determinations of masses and radii. The measured radii are consistently larger than standard stellar models predict by several percent. These four systems potentially provide the most challenging tests of precision evolutionary models of cool dwarfs at the present time. We have previously modeled M dwarfs in the context of a criterion due to Gough and Tayler in which magnetic fields inhibit the onset of convection according to a physics-based prescription. In the present paper, we apply our magnetoconvective approach to the four prime systems in the Torres list. Going a step beyond what we have already modeled in CM Dra (one of the four Torres systems), we note that new constraints on magnetoconvective models of M dwarfs are now available from empirical estimates of magnetic field strengths on the surfaces of these stars. In the present paper, we consider how well our magnetoconvective models succeed when confronted with this new test of surface magnetic field strengths. Among the systems listed by Torres, we find that plausible magnetic models work well for CM Dra, YY Gem, and CU Cnc. (The fourth system in Torres's list does not yet have enough information to warrant magnetic modeling.) Our magnetoconvection models of CM Dra, YY Gem, and CU Cnc yield predictions of the magnetic fluxes on the stellar surface which are consistent with the observed correlation between magnetic flux and X-ray luminosity.

  5. Surface Magnetic Field Strengths: New Tests of Magnetoconvective Models of M Dwarfs

    Science.gov (United States)

    MacDonald, James; Mullan, D. J.

    2014-05-01

    Precision modeling of M dwarfs has become worthwhile in recent years due to the increasingly precise values of masses and radii which can be obtained from eclipsing binary studies. In a recent paper, Torres has identified four prime M dwarf pairs with the most precise empirical determinations of masses and radii. The measured radii are consistently larger than standard stellar models predict by several percent. These four systems potentially provide the most challenging tests of precision evolutionary models of cool dwarfs at the present time. We have previously modeled M dwarfs in the context of a criterion due to Gough & Tayler in which magnetic fields inhibit the onset of convection according to a physics-based prescription. In the present paper, we apply our magnetoconvective approach to the four prime systems in the Torres list. Going a step beyond what we have already modeled in CM Dra (one of the four Torres systems), we note that new constraints on magnetoconvective models of M dwarfs are now available from empirical estimates of magnetic field strengths on the surfaces of these stars. In the present paper, we consider how well our magnetoconvective models succeed when confronted with this new test of surface magnetic field strengths. Among the systems listed by Torres, we find that plausible magnetic models work well for CM Dra, YY Gem, and CU Cnc. (The fourth system in Torres's list does not yet have enough information to warrant magnetic modeling.) Our magnetoconvection models of CM Dra, YY Gem, and CU Cnc yield predictions of the magnetic fluxes on the stellar surface which are consistent with the observed correlation between magnetic flux and X-ray luminosity.

  6. Test-Retest Reliability of Isokinetic Knee Strength Measurements in Children Aged 8 to 10 Years.

    Science.gov (United States)

    Fagher, Kristina; Fritzson, Annelie; Drake, Anna Maria

    Isokinetic dynamometry is a useful tool to objectively assess muscle strength of children and adults in athletic and rehabilitative settings. This study examined test-retest reliability of isokinetic knee strength measurements in children aged 8 to 10 years and defined limits for the minimum difference (MD) in strength that indicates a clinically important change. Isokinetic knee strength measurements (using the Biodex System 4) in children will provide reliable results. Descriptive laboratory study. In 22 healthy children, 5 maximal concentric (CON) knee extensor (KE) and knee flexor (KF) contractions at 2 angular velocities (60 deg/s and 180 deg/s) and 5 maximal eccentric (ECC) KE/KF contractions at 60 deg/s were assessed 7 days apart. The intraclass correlation coefficient (ICC 2.1 ) was used to examine relative reliability, and the MD was calculated on the basis of standard error of measurement. ICCs for CON KE/KF peak torque measurements were fair to excellent (range, 0.49-0.81). The MD% values for CON KE and KF ranged from 31% to 37% at 60 deg/s and from 34% to 39% at 180 deg/s. ICCs in the ECC mode were good (range, 0.60-0.70), but associated MD% values were high (>50%). There was no systematic error for CON KE/KF and ECC KE strength measurements at 60 deg/s, but systematic error was found for all other measurements. The dynamometer provides a reliable analysis of isokinetic CON knee strength measurements at 60 deg/s in children aged 8 to 10 years. Measurements at 180 deg/s and in the ECC mode were not reliable, indicating a need for more familiarization prior to testing. The MD values may help clinicians to determine whether a change in knee strength is due to error or intervention.

  7. Flexural strength of proof-tested and neutron-irradiated silicon carbide

    Science.gov (United States)

    Price, R. J.; Hopkins, G. R.

    1982-08-01

    Proof testing before service is a valuable method for ensuring the reliability of ceramic structures. Silicon carbide has been proposed as a very low activation first-wall and blanket structural material for fusion devices, where it would experience a high flux of fast neutrons. Strips of three types of silicon carbide were loaded in four-point bending to a stress sufficient to break about a third of the specimens. Groups of 16 survivors were irradiated to 2 × 10 26n/ m2 ( E>0.05 MeV) at 740°C and bend tested to failure. The strength distribution of chemically vapor-deposited silicon carbide (Texas Instruments) was virtually unchanged by irradiation. The mean strength of sintered silicon carbide (Carborundum Alpha) was reduced 34% by irradiation, while the Weibull modulus and the truncated strength distribution characteristic of proof-tested material were retained. Irradiation reduced the mean strength of reaction-bonded silicon carbide (Norton NC-430) by 58%, and the spread in strength values was increased. We conclude that for the chemically vapor-deposited and the sintered silicon carbide the benefits of proof testing to eliminate low strength material are retained after high neutron exposures.

  8. Three-fold increase of M1 strength in 40Ar at 10 MeV excitation energy

    Science.gov (United States)

    Tornow, Werner; Finch, Sean; Krishichayan, Fnu; Tonchev, Anton

    2017-09-01

    We reexamined the excitation energy region of 40Ar around 9.8 MeV with the goal of determining the known M1 strength located at 9.76 MeV more accurately. The physics motivation was based on the fact that i) the neutrino-nucleus interaction cross section is proportional to the M1 strength of a nucleus, ii) DUNE, the Deep Underground Neutrino Experiment at SURF will be using liquid argon as detector medium, iii) the energy spectrum of supernova neutrinos is peaked at approximately 10 MeV. Mono-energetic and linearly polarized photons of 9.88 MeV were produced via Compton backscattering of 548 nm FEL photons from 543 MeV electrons at the High-Intensity γ-ray Source (HI γS) facility at TUNL. The 1.25 cm diameter photon beam with energy spread of 300 keV (FWHM) interacted with argon gas contained in a high-pressure cell. The cell was viewed with HPGe detectors placed at 90o relative to the incident photon beam in the horizontal and vertical planes to distinguish between E1 and M1 de-excitation γ-rays. Our re-measurement provided an increase in M1 strength by a factor of approximately 3, mostly due to the discovery that the known level in 40Ar at 9.84 MeV is of M1 character and not of E1 character, as previously thought. In addition to the already known M1 state at 9.76 MeV, we observed weaker M1 states at 9.70, 9.81, 9.87, and 9.89 MeV.

  9. Strength testing and training of rowers: a review.

    Science.gov (United States)

    Lawton, Trent W; Cronin, John B; McGuigan, Michael R

    2011-05-01

    In the quest to maximize average propulsive stroke impulses over 2000-m racing, testing and training of various strength parameters have been incorporated into the physical conditioning plans of rowers. Thus, the purpose of this review was 2-fold: to identify strength tests that were reliable and valid correlates (predictors) of rowing performance; and, to establish the benefits gained when strength training was integrated into the physical preparation plans of rowers. The reliability of maximal strength and power tests involving leg extension (e.g. leg pressing) and arm pulling (e.g. prone bench pull) was high (intra-class correlations 0.82-0.99), revealing that elite rowers were significantly stronger than their less competitive peers. The greater strength of elite rowers was in part attributed to the correlation between strength and greater lean body mass (r = 0.57-0.63). Dynamic lower body strength tests that determined the maximal external load for a one-repetition maximum (1RM) leg press (kg), isokinetic leg extension peak force (N) or leg press peak power (W) proved to be moderately to strongly associated with 2000-m ergometer times (r = -0.54 to -0.68; p training experience and muscle morphology, in that those individuals with greater training experience and/or proportions of slow twitch fibres performed more repetitions. Muscle balance ratios derived from strength data (e.g. hamstring-quadriceps ratio training may be counterproductive to strength development over the shorter term (i.e. training within the sequence of training units should be considered, particularly over the non-competition phase (e.g. 2-6 sets × 4-12 repetitions, three sessions a week). Maximal strength was sustained when infrequent (e.g. one or two sessions a week) but intense (e.g. 73-79% of maximum) strength training units were scheduled; however, it was unclear whether training adaptations should emphasize maximal strength, endurance or power in order to enhance

  10. Strength behaviour of 10CrMo9.10 steel in nonsteady-state applications

    International Nuclear Information System (INIS)

    Seidel, C.

    2 testing runs with cyclic temperature increase were conducted on steel 10CrMo9.10 samples, i.e., at 500 degC and cyclic increase by 10, 25 and 50 degC, and at 550 degC and cyclic increase by 50 degC. Long-term strength was studied under a strain of 6.1 to 25.6 kp/mm 2 for 22,000 hours and the effect of periodical unloading was investigated on long-term strength at 550 degC. Sample loading and unloading proceeded within the range of 8.8 to 24.7 kp/mm 2 at an unloading rate of 8 to 100 %/min. Steel lifetime was not affected by the number of cycles. The effect of the changing load and of constant temperature without load on the long-term strength of the steel at 550 degC is shown graphically. The results showed a clear dependence of steel life on dwell time at the given temperature without load. (J.P.)

  11. CANFLEX fuel bundle strength tests (test report)

    International Nuclear Information System (INIS)

    Chang, Seok Kyu; Chung, C. H.; Kim, B. D.

    1997-08-01

    This document outlines the test results for the strength tests of the CANFLEX fuel bundle. Strength tests are performed to determine and verify the amount of the bundle shape distortion which is against the side-stops when the bundles are refuelling. There are two cases of strength test; one is the double side-stop test which simulates the normal bundle refuelling and the other is the single side-stop test which simulates the abnormal refuelling. the strength test specification requires that the fuel bundle against the side-stop(s) simulators for this test were fabricated and the flow rates were controlled to provide the required conservative hydraulic forces. The test rig conditions of 120 deg C, 11.2 MPa were retained for 15 minutes after the flow rate was controlled during the test in two cases, respectively. The bundle loading angles of number 13- number 15 among the 15 bundles were 67.5 deg CCW and others were loaded randomly. After the tests, the bundle shapes against the side-stops were measured and inspected carefully. The important test procedures and measurements were discussed as follows. (author). 5 refs., 22 tabs., 5 figs

  12. Shear Strength Measurement Benchmarking Tests for K Basin Sludge Simulants

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Carolyn A.; Daniel, Richard C.; Enderlin, Carl W.; Luna, Maria; Schmidt, Andrew J.

    2009-06-10

    Equipment development and demonstration testing for sludge retrieval is being conducted by the K Basin Sludge Treatment Project (STP) at the MASF (Maintenance and Storage Facility) using sludge simulants. In testing performed at the Pacific Northwest National Laboratory (under contract with the CH2M Hill Plateau Remediation Company), the performance of the Geovane instrument was successfully benchmarked against the M5 Haake rheometer using a series of simulants with shear strengths (τ) ranging from about 700 to 22,000 Pa (shaft corrected). Operating steps for obtaining consistent shear strength measurements with the Geovane instrument during the benchmark testing were refined and documented.

  13. A novel blister test to evaluate the interface strength between nickel coating and low carbon steel substrate

    International Nuclear Information System (INIS)

    Xiao, L.H.; Su, Xu Ping.; Wang, J.H.; Zhou, Y.C.

    2009-01-01

    A novel blister test theory model was developed based on the bending theory of beams for assessing the interface strength of the nickel coating/low carbon steel substrate material system. The strain energy of the debonded nickel coating was calculated analytically and by finite element analysis, respectively. The analytic solutions agree well with the FE calculation results. Some blister tests were carried out on the WII-5 Computer Controlled Material Mechanical Properties Testing Machine, using four nickel-coated specimens type-A, -B, -C and -D which were electrodeposited on low carbon steel substrate. Here, types A, B, C and D correspond to the nickel coating thickness of 5 μm, 10 μm, 15μm and 25μm, respectively. The interface strength, evaluated by this blister test method, is 196.86 J/m 2 and 269.40 J/m 2 for type-C and -D specimens, respectively. However the tests demonstrate that the type-A and -B specimens were cut through by the spindle and no delaminations between the coating and the substrate could be found

  14. Impact strength of sintered astaloy CrM powders

    International Nuclear Information System (INIS)

    Kazior, J.; Ploszczak, J.; Nykiel, M.; Pieczonka, T.

    2003-01-01

    In this paper results of a series of impact tests on sintered Astaloy CrM powders alloys modified by boron are presented and discussed. Boron in different forms, i.e. as elemental boron powder, boron carbide B 4 C powder or mixture of boron and carbon elemental powders, was used in different weight percentage to activate sintering of Astaloy CrM powder and to increase hardenability, with aim of increasing impact strength in view of structural applications. (author)

  15. Creep strength of 10 CrMo 9 10 welding material

    International Nuclear Information System (INIS)

    Maile, K.; Theofel, H.

    1993-01-01

    Samples from different welding materials of the heat-resistant steel 10 Cr Mo 10 were subjected to creep tests. The maximum duration of stressing was 36,000 hours. At a text temperature of 450 C, the creep behaviour is considerably affected by different initial strengths. At 500 and 550 C, the creep fracture points for most of the welding materials in the long term range lie scattered in a relatively narrow band. This range is at or just below the lower scatteer band limit of the basic material (corresponding to DIN 17175, mean value ± 20%. (orig.) [de

  16. Investigating the Effects of Typical Rowing Strength Training Practices on Strength and Power Development and 2,000 m Rowing Performance

    Directory of Open Access Journals (Sweden)

    Ian Gee Thomas

    2016-04-01

    Full Text Available This study aimed to determine the effects of a short-term, strength training intervention, typically undertaken by club-standard rowers, on 2,000 m rowing performance and strength and power development. Twenty-eight male rowers were randomly assigned to intervention or control groups. All participants performed baseline testing involving assessments of muscle soreness, creatine kinase activity (CK, maximal voluntary contraction (leg-extensors (MVC, static-squat jumps (SSJ, counter-movement jumps (CMJ, maximal rowing power strokes (PS and a 2,000 m rowing ergometer time-trial (2,000 m with accompanying respiratory-exchange and electromyography (EMG analysis. Intervention group participants subsequently performed three identical strength training (ST sessions, in the space of five days, repeating all assessments 24 h following the final ST. The control group completed the same testing procedure but with no ST. Following ST, the intervention group experienced significant elevations in soreness and CK activity, and decrements in MVC, SSJ, CMJ and PS (p < 0.01. However, 2,000 m rowing performance, pacing strategy and gas exchange were unchanged across trials in either condition. Following ST, significant increases occurred for EMG (p < 0.05, and there were non-significant trends for decreased blood lactate and anaerobic energy liberation (p = 0.063 – 0.086. In summary, club-standard rowers, following an intensive period of strength training, maintained their 2,000 m rowing performance despite suffering symptoms of muscle damage and disruption to muscle function. This disruption likely reflected the presence of acute residual fatigue, potentially in type II muscle fibres as strength and power development were affected.

  17. Chairside CAD/CAM materials. Part 2: Flexural strength testing.

    Science.gov (United States)

    Wendler, Michael; Belli, Renan; Petschelt, Anselm; Mevec, Daniel; Harrer, Walter; Lube, Tanja; Danzer, Robert; Lohbauer, Ulrich

    2017-01-01

    Strength is one of the preferred parameters used in dentistry for determining clinical indication of dental restoratives. However, small dimensions of CAD/CAM blocks limit reliable measurements with standardized uniaxial bending tests. The objective of this study was to introduce the ball-on-three-ball (B3B) biaxial strength test for dental for small CAD/CAM block in the context of the size effect on strength predicted by the Weibull theory. Eight representative chairside CAD/CAM materials ranging from polycrystalline zirconia (e.max ZirCAD, Ivoclar-Vivadent), reinforced glasses (Vitablocs Mark II, VITA; Empress CAD, Ivoclar-Vivadent) and glass-ceramics (e.max CAD, Ivoclar-Vivadent; Suprinity, VITA; Celtra Duo, Dentsply) to hybrid materials (Enamic, VITA; Lava Ultimate, 3M ESPE) have been selected. Specimens were prepared with highly polished surfaces in rectangular plate (12×12×1.2mm 3 ) or round disc (Ø=12mm, thickness=1.2mm) geometries. Specimens were tested using the B3B assembly and the biaxial strength was determined using calculations derived from finite element analyses of the respective stress fields. Size effects on strength were determined based on results from 4-point-bending specimens. A good agreement was found between the biaxial strength results for the different geometries (plates vs. discs) using the B3B test. Strength values ranged from 110.9MPa (Vitablocs Mark II) to 1303.21MPa (e.max ZirCAD). The strength dependency on specimen size was demonstrated through the calculated effective volume/surface. The B3B test has shown to be a reliable and simple method for determining the biaxial strength restorative materials supplied as small CAD/CAM blocks. A flexible solution was made available for the B3B test in the rectangular plate geometry. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  18. Test-retest reliability and minimal detectable change scores for sit-to-stand-to-sit tests, the six-minute walk test, the one-leg heel-rise test, and handgrip strength in people undergoing hemodialysis.

    Science.gov (United States)

    Segura-Ortí, Eva; Martínez-Olmos, Francisco José

    2011-08-01

    Determining the relative and absolute reliability of outcomes of physical performance tests for people undergoing hemodialysis is necessary to discriminate between the true effects of exercise interventions and the inherent variability of this cohort. The aims of this study were to assess the relative reliability of sit-to-stand-to-sit tests (the STS-10, which measures the time [in seconds] required to complete 10 full stands from a sitting position, and the STS-60, which measures the number of repetitions achieved in 60 seconds), the Six-Minute Walk Test (6MWT), the one-leg heel-rise test, and the handgrip strength test and to calculate minimal detectable change (MDC) scores in people undergoing hemodialysis. This study was a prospective, nonexperimental investigation. Thirty-nine people undergoing hemodialysis at 2 clinics in Spain were contacted. Study participants performed the STS-10 (n=37), the STS-60 (n=37), and the 6MWT (n=36). At one of the settings, the participants also performed the one-leg heel-rise test (n=21) and the handgrip strength test (n=12) on both the right and the left sides. Participants attended 2 testing sessions 1 to 2 weeks apart. High intraclass correlation coefficients (≥.88) were found for all tests, suggesting good relative reliability. The MDC scores at 90% confidence intervals were as follows: 8.4 seconds for the STS-10, 4 repetitions for the STS-60, 66.3 m for the 6MWT, 3.4 kg for handgrip strength (force-generating capacity), 3.7 repetitions for the one-leg heel-rise test with the right leg, and 5.2 repetitions for the one-leg heel-rise test with the left leg. Limitations A limited sample of patients was used in this study. The STS-16, STS-60, 6MWT, one-leg heel rise test, and handgrip strength test are reliable outcome measures. The MDC scores at 90% confidence intervals for these tests will help to determine whether a change is due to error or to an intervention.

  19. Feasibility and test-retest reliability of measuring lower‑limb strength in young children with cerebral palsy.

    Science.gov (United States)

    Van Vulpen, L F; De Groot, S; Becher, J G; De Wolf, G S; Dallmeijer, A J

    2013-12-01

    Quantifying leg muscle strength in young children with cerebral palsy (CP) is essential for identifying muscle groups for treatment and for monitoring progress. To study the feasibility, intratester reliability and the optimal test design (number of test occasions and repetitions) of measuring lower-limb strength with handheld dynamometry (HHD) and dynamic ankle plantar flexor strength with the standing heel-rise (SH) test in 3-10 year aged children with CP. Test-retest design. Rehabilitation centre, special needs school for children with disabilities, and university medical centre. Knee extensor, hip abductor and calf muscle strength was assessed in 20 ambulatory children with spastic CP (3-5 years [N.=10] and 6-10 years [N.=10]) on two test occasions. Intraclass correlation coefficients (ICC) and Smallest Detectable Differences (SDD) were calculated to determine the optimal test design for detecting changes in strength. All isometric strength tests had acceptable SDDs (9-30%), when taking the mean values of 2-3 test occasions (separate days) and 2-3 repetitions. The one-leg SH test had large SDDs (40-128% for younger group, 23-48% for older group). Isometric strength (improvements) can only be measured reliably with HHD in young children with CP when the average values over at least 2 test occasions are taken. Reliability of the SH test is not sufficient for measuring individual changes in dynamic muscle strength in the younger children. Results of this study can be used to determine the optimal number of test occasions and repetitions for reliable HHD measurements depending on expected changes, muscle group and age in 3-10 year old children with CP.

  20. Static, Fire and Fatigue Tests of Ultra High-Strength Fibre Reinforced Concrete and Ribbed Bars

    DEFF Research Database (Denmark)

    Hansen, Lars Pilegaard; Heshe, Gert

    2001-01-01

    A new building system has been developed during the last 10 years. This new system consists of a column / slab system with 6 x 6 m distance between the columns. The slabs are precast concrete elements of size 2.9 x 5.9 m connected through joints of ultra high strength fibre reinforced concrete...... - Densit Joint Cast ®. Also the connections between the columns and the slabs are made of this very strong concrete material. The paper describes some of the static tests carried out as well as some fire tests. Further, 2 chapters deal with some fatigue tests of the reinforcing bars as well as some fatigue...

  1. Accelerated Strength Testing of Thermoplastic Composites

    Science.gov (United States)

    Reeder, J. R.; Allen, D. H.; Bradley, W. L.

    1998-01-01

    Constant ramp strength tests on unidirectional thermoplastic composite specimens oriented in the 90 deg. direction were conducted at constant temperatures ranging from 149 C to 232 C. Ramp rates spanning 5 orders of magnitude were tested so that failures occurred in the range from 0.5 sec. to 24 hrs. (0.5 to 100,000 MPa/sec). Below 204 C, time-temperature superposition held allowing strength at longer times to be estimated from strength tests at shorter times but higher temperatures. The data indicated that a 50% drop in strength might be expected for this material when the test time is increased by 9 orders of magnitude. The shift factors derived from compliance data applied well to the strength results. To explain the link between compliance and strength, a viscoelastic fracture model was investigated. The model, which used compliance as input, was found to fit the strength data only if the critical fracture energy was allowed to vary with temperature reduced stress rate. This variation in the critical parameter severely limits its use in developing a robust time-dependent strength model. The significance of this research is therefore seen as providing both the indication that a more versatile acceleration method for strength can be developed and the evidence that such a method is needed.

  2. Insulation interlaminar shear strength testing with compression and irradiation

    International Nuclear Information System (INIS)

    McManamy, T.J.; Brasier, J.E.; Snook, P.

    1989-01-01

    The Compact Ignition Tokamak (CIT) project identified the need for research and development for the insulation to be used in the toroidal field coils. The requirements included tolerance to a combination of high compression and shear and a high radiation dose. Samples of laminate-type sheet material were obtained from commercial vendors. The materials included various combinations of epoxy, polyimide, E-glass, S-glass, and T-glass. The T-glass was in the form of a three-dimensional weave. The first tests were with 50 x 25 x 1 mm samples. These materials were loaded in compression and then to failure in shear. At 345-MPa compression, the interlaminar shear strength was generally in the range of 110 to 140 MPa for the different materials. A smaller sample configuration was developed for irradiation testing. The data before irradiation were similar to those for the larger samples but approximately 10% lower. Limited fatigue testing was also performed by cycling the shear load. No reduction in shear strength was found after 50,000 cycles at 90% of the failure stress. Because of space limitations, only three materials were chosen for irradiation: two polyimide systems and one epoxy system. All used boron-free glass. The small shear/compression samples and some flexure specimens were irradiated to 4 x 10 9 and 2 x 10 10 rad in the Advanced Technology Reactor at Idaho National Engineering Laboratory. A lead shield was used to ensure that the majority of the dose was from neutrons. The shear strength with compression before and after irradiation at the lower dose was determined. Flexure strength and the results from irradiation at the higher dose level will be available in the near future. 7 refs., 7 figs., 2 tabs

  3. Probe tests microweld strength

    Science.gov (United States)

    1965-01-01

    Probe is developed to test strength of soldered, brazed or microwelded joints. It consists of a spring which may be adjusted to the desired test pressure by means of a threaded probe head, and an indicator lamp. Device may be used for electronic equipment testing.

  4. A NEW CLINICAL MUSCLE FUNCTION TEST FOR ASSESSMENT OF HIP EXTERNAL ROTATION STRENGTH: AUGUSTSSON STRENGTH TEST.

    Science.gov (United States)

    Augustsson, Jesper

    2016-08-01

    Dynamic clinical tests of hip strength applicable on patients, non-athletes and athletes alike, are lacking. The aim of this study was therefore to develop and evaluate the reliability of a dynamic muscle function test of hip external rotation strength, using a novel device. A second aim was to determine if gender differences exist in absolute and relative hip strength using the new test. Fifty-three healthy sport science students (34 women and 19 men) were tested for hip external rotation strength using a device that consisted of a strap connected in series with an elastic resistance band loop, and a measuring tape connected in parallel with the elastic resistance band. The test was carried out with the subject side lying, positioned in 45 ° of hip flexion and the knees flexed to 90 ° with the device firmly fastened proximally across the knees. The subject then exerted maximal concentric hip external rotation force against the device thereby extending the elastic resistance band. The displacement achieved by the subject was documented by the tape measure and the corresponding force production was calculated. Both right and left hip strength was measured. Fifteen of the subjects were tested on repeated occasions to evaluate test-retest reliability. No significant test-retest differences were observed. Intra-class correlation coefficients ranged 0.93-0.94 and coefficients of variation 2.76-4.60%. In absolute values, men were significantly stronger in hip external rotation than women (right side 13.2 vs 11.0 kg, p = 0.001, left side 13.2 vs 11.5 kg, p = 0.002). There were no significant differences in hip external rotation strength normalized for body weight (BW) between men and women (right side 0.17 kg/BW vs 0.17 kg/BW, p = 0.675, left side 0.17 kg/BW vs 0.18 kg/BW, p = 0.156). The new muscle function test showed high reliability and thus could be useful for measuring dynamic hip external rotation strength in patients, non-athletes and athletes

  5. Maximal Strength Testing in Healthy Children.

    Science.gov (United States)

    Faigenbaum, Avery D.; Milliken, Laurie A.; Westcott, Wayne L.

    2003-01-01

    Evaluated the safety and efficacy of 1 repetition maximum (1RM) strength testing in healthy children age 6-12 years. Data were collected on 96 children who performed a 1RM test on one upper body and one lower body exercise using child-sized weight machines. Findings indicated that children could safely perform 1RM strength tests provided…

  6. Equipment and Protocols for Quasi-Static and Dynamic Tests of Very-High-Strength Concrete (VHSC) and High-Strength High-Ductility Concrete (HSHDC)

    Science.gov (United States)

    2016-08-01

    Concrete (VHSC) and High-Strength High-Ductility Concrete (HSHDC) En gi ne er R es ea rc h an d D ev el op m en t Ce nt er Brett A...Very-High-Strength Concrete (VHSC) and High-Strength High-Ductility Concrete (HSHDC) Brett A. Williams, Robert D. Moser, William F. Heard, Carol F...equipment and protocols for tests of both very-high-strength concrete (VHSC) and high- strength high-ductility concrete (HSHDC) to predict blast

  7. Application of stress relaxation testing in evaluation of creep strength of a tungsten-alloyed 10% Cr cast steel

    International Nuclear Information System (INIS)

    Raghavender Rao, G.; Gupta, O.P.; Pradhan, B.

    2011-01-01

    Uniaxial isothermal stress relaxation tests (SRT) were performed on a tungsten-alloyed 10% Cr cast steel (G-X12Cr Mo W V Nb N 10 1 1) at temperatures of 580, 600 and 620 o C and initial strain levels of 0.2, 0.5 and 0.8%. Inelastic strain rates for different stresses were estimated from the stress versus time data generated from the tests. Conventional creep tests were also conducted on the same material at 580, 600 and 620 o C and at different stress levels. The strain rate data estimated from SRT were compared with minimum creep rates derived from the creep tests; the strain rates estimated from SRT with 0.8% initial strain level are in better agreement than those estimated from SRT with 0.2 and 0.5% initial strain levels. In order to ascertain the technique, stress relaxation behaviour was estimated from creep test data and compared with the stress relaxation curves obtained from SRT at corresponding temperatures. The stress relaxation curves obtained from SRT with 0.8% initial strain level are in good agreement with the stress relaxation curves estimated from the creep tests. It is concluded that the stress relaxation test with initial strain level of 0.8% could be considered as an appropriate short-term test technique for estimation of creep strength of newly developed materials.

  8. The Effects of a 6-Week Strength Training on Critical Velocity, Anaerobic Running Distance, 30-M Sprint and Yo-Yo Intermittent Running Test Performances in Male Soccer Players.

    Science.gov (United States)

    Karsten, Bettina; Larumbe-Zabala, Eneko; Kandemir, Gokhan; Hazir, Tahir; Klose, Andreas; Naclerio, Fernando

    2016-01-01

    The objectives of this study were to examine the effects of a moderate intensity strength training on changes in critical velocity (CV), anaerobic running distance (D'), sprint performance and Yo-Yo intermittent running test (Yo-Yo IR1) performances. two recreational soccer teams were divided in a soccer training only group (SO; n = 13) and a strength and soccer training group (ST; n = 13). Both groups were tested for values of CV, D', Yo-Yo IR1 distance and 30-m sprint time on two separate occasions (pre and post intervention). The ST group performed a concurrent 6-week upper and lower body strength and soccer training, whilst the SO group performed a soccer only training. after the re-test of all variables, the ST demonstrated significant improvements for both, YoYo IR1 distance (p = 0.002) and CV values (psoccer training significantly improves CV, Yo-Yo IR1 whilst moderately improving 30-m sprint performances in non-previously resistance trained male soccer players. Critical Velocity can be recommended to coaches as an additional valid testing tool in soccer.

  9. 16 CFR Figure 8 to Part 1203 - Apparatus for Test of Retention System Strength

    Science.gov (United States)

    2010-01-01

    ...—Apparatus for Test of Retention System Strength ER10MR98.008 ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Apparatus for Test of Retention System Strength 8 Figure 8 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT...

  10. Residual-strength tests of L-1011 vertical fin components after 10 and 20 years of simulated flight service

    Science.gov (United States)

    Lopez, O. F.

    1984-01-01

    Part of the NASA/ACEE Program was to determine the effect of long-term durability testing on the residual strength of graphite-epoxy cover panel and spar components of the Lockheed L-1011 aircraft vertical stabilizer. The results of these residual strength tests are presented herein. The structural behavior and failure mode of both cover panel and spar components were addressed, and the test results obtained were compared with the static test results generated by Lockheed. The effect of damage on one of the spar specimens was described.

  11. Comparison of two bond strength testing methodologies for bilayered all-ceramics.

    Science.gov (United States)

    Dündar, Mine; Ozcan, Mutlu; Gökçe, Bülent; Cömlekoğlu, Erhan; Leite, Fabiola; Valandro, Luiz Felipe

    2007-05-01

    This study compared the shear bond strength (SBS) and microtensile (MTBS) testing methodologies for core and veneering ceramics in four types of all-ceramic systems. Four different ceramic veneer/core combinations, three of which were feldspathic and the other a fluor-apatite to their respectively corresponding cores, namely leucite-reinforced ceramic ((IPS)Empress, Ivoclar), low leucite-reinforced ceramic (Finesse, Ceramco), glass-infiltrated alumina (In-Ceram Alumina, Vita) and lithium disilicate ((IPS)Empress 2, Ivoclar) were used for SBS and MTBS tests. Ceramic cores (N=40, n=10/group for SBS test method, N=5 blocks/group for MTBS test method) were fabricated according to the manufacturers' instructions (for SBS: thickness, 3mm; diameter, 5mm and for MTBS: 10 mm x 10 mm x 2 mm) and ultrasonically cleaned. The veneering ceramics (thickness: 2mm) were vibrated and condensed in stainless steel moulds and fired onto the core ceramic materials. After trying the specimens in the mould for minor adjustments, they were again ultrasonically cleaned and embedded in PMMA. The specimens were stored in distilled water at 37 degrees C for 1 week and bond strength tests were performed in universal testing machines (cross-head speed: 1mm/min). The bond strengths (MPa+/-S.D.) and modes of failures were recorded. Significant difference between the two test methods and all-ceramic types were observed (P<0.05) (2-way ANOVA, Tukey's test and Bonferroni). The mean SBS values for veneering ceramic to lithium disilicate was significantly higher (41+/-8 MPa) than those to low leucite (28+/-4 MPa), glass-infiltrated (26+/-4 MPa) and leucite-reinforced (23+/-3 MPa) ceramics, while the mean MTBS for low leucite ceramic was significantly higher (15+/-2 MPa) than those of leucite (12+/-2 MPa), glass-infiltrated (9+/-1 MPa) and lithium disilicate ceramic (9+/-1 MPa) (ANOVA, P<0.05). Both the testing methodology and the differences in chemical compositions of the core and veneering ceramics

  12. Relationships between Sprint, Jumping and Strength Abilities, and 800 M Performance in Male Athletes of National and International Levels.

    Science.gov (United States)

    Bachero-Mena, Beatriz; Pareja-Blanco, Fernando; Rodríguez-Rosell, David; Yáñez-García, Juan Manuel; Mora-Custodio, Ricardo; González-Badillo, Juan José

    2017-09-01

    This study analysed the relationships between sprinting, jumping and strength abilities, with regard to 800 m running performance. Fourteen athletes of national and international levels in 800 m (personal best: 1:43-1:58 min:ss) completed sprint tests (20 m and 200 m), a countermovement jump, jump squat and full squat test as well as an 800 m race. Significant relationships (p relationship between the first to the last 50 m interval times and the 800 m time tended to increase (1st 50 m: r = 0.71; 2nd 50 m: r = 0.72; 3rd 50 m: r = 0.81; 4th 50 m: r = 0.85). Performance in 800 m also correlated significantly (p < 0.01-0.05) with strength variables: the countermovement jump (r = -0.69), jump squat (r = -0.65), and full squat test (r = -0.58). Performance of 800 m in high-level athletes was related to sprint, strength and jumping abilities, with 200 m and the latest 50 m of the 200 m being the variables that most explained the variance of the 800 m performance.

  13. Investigation and clinical applications of muscle strength change in cerebrospinal fluid tap test in cases of idiopathic normal pressure hydrocephalus: A retrospective study.

    Science.gov (United States)

    Matsuoka, Tsuyoshi; Iida, Jun-Ichi; Kawahara, Makoto; Uchiyama, Yoshitomo

    2016-12-15

    The cerebrospinal fluid tap test (CSFTT) is widely used to diagnose idiopathic normal pressure hydrocephalus (iNPH) and predict the therapeutic effectiveness of shunting. However, the ability to walk cannot be quantified for patients who are unable to walk. Therefore, we examined whether the iNPH diagnostic aid is possible using dynamometry, even for patients who are unable to walk. In this study, 45 patients underwent grip strength assessment, quadriceps strength assessment, 10-m walk test, and 3-m Timed Up and Go test before and after CSFTT. Our investigation of physical functions indicated that the CSFTT-positive group demonstrated significant improvements in grip and bilateral quadriceps muscle strength. The results of the receiver operating characteristic analysis indicated that leg muscle strength measurement reliability was high and that the area under the curve was 0.754-0.811. Our investigation of the clinically effective cutoff point for the rate of change indicated that it was 13.6% for right quadriceps muscle strength and 15.3% for left quadriceps muscle strength. Comparing CSFTT results in cases of iNPH with the observed rate of change in muscle strength can aid in the diagnosis of iNPH. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Static and Dynamic Handgrip Strength Endurance: Test-Retest Reproducibility.

    Science.gov (United States)

    Gerodimos, Vassilis; Karatrantou, Konstantina; Psychou, Dimitra; Vasilopoulou, Theodora; Zafeiridis, Andreas

    2017-03-01

    This study investigated the reliability of static and dynamic handgrip strength endurance using different protocols and indicators for the assessment of strength endurance. Forty young, healthy men and women (age, 18-22 years) performed 2 handgrip strength endurance protocols: a static protocol (sustained submaximal contraction at 50% of maximal voluntary contraction) and a dynamic one (8, 10, and 12 maximal repetitions). The participants executed each protocol twice to assess the test-retest reproducibility. Total work and total time were used as indicators of strength endurance in the static protocol; the strength recorded at each maximal repetition, the percentage change, and fatigue index were used as indicators of strength endurance in the dynamic protocol. The static protocol showed high reliability irrespective of sex and hand for total time and work. The 12-repetition dynamic protocol exhibited moderate-high reliability for repeated maximal repetitions and percentage change; the 8- and 10-repetition protocols demonstrated lower reliability irrespective of sex and hand. The fatigue index was not a reliable indicator for the assessment of dynamic handgrip endurance. Static handgrip endurance can be measured reliably using the total time and total work as indicators of strength endurance. For the evaluation of dynamic handgrip endurance, the 12-repetition protocol is recommended, using the repeated maximal repetitions and percentage change as indicators of strength endurance. Practitioners should consider the static (50% maximal voluntary contraction) and dynamic (12 repeated maximal repetitions) protocols as reliable for the assessment of handgrip strength endurance. The evaluation of static endurance in conjunction with dynamic endurance would provide more complete information about hand function. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Effect of 10% sodium bicarbonate on bond strength of enamel and dentin after bleaching with 38% hydrogen peroxide

    Directory of Open Access Journals (Sweden)

    Fernanda Medeiros Darzé

    Full Text Available AbstractIntroductionBy-products of hydrogen peroxide degradation released during dental bleaching influence the polymerization of adhesive systems and composite resins, causing a reduction in shear bond strength to the tooth.Objectivethe aim of this article was to evaluate the effect of 10% sodium bicarbonate (SB, applied for different lengths of time, on the shear bond strength to enamel and dentin after bleaching.Material and methodEnamel and dentin blocks were divided into groups (n=10: (1 control: no bleaching; (2 immediate: bleaching immediately followed by restoration; (3 14-day: bleaching, restoration 14 days later; (4 SB for 10 minutes: bleaching, SB gel for 10 minutes, immediately followed by restoration; (5 SB for 20 minutes: bleaching, SB gel for 20 minutes, immediately followed by restoration. A 38% hydrogen peroxide gel (Opalescence Boost/Ultradent was used. After application of the adhesive system, composite resin cylinders were mounted on the surface of the substrates in order to test shear bond strength. Result: ANOVA and Tukey tests showed significantly higher mean enamel bond strength values for the 14-day follow-up group and without significant differences for control group. Mean bond strength values obtained for the other groups were intermediate. When testing dentin, the Tukey test revealed a significantly higher mean bond strength value for the 14-day follow-up group when compared with application of SB for 20 minutes.ConclusionSB gel applied was unable to reverse the low bond strength to enamel and dentin after bleaching treatment.

  16. THE EFFICACY OF ANGLE-MATCHED ISOKINETIC KNEE FLEXOR AND EXTENSOR STRENGTH PARAMETERS IN PREDICTING AGILITY TEST PERFORMANCE.

    Science.gov (United States)

    Greig, Matt; Naylor, James

    2017-10-01

    Agility is a fundamental performance element in many sports, but poses a high risk of injury. Hierarchical modelling has shown that eccentric hamstring strength is the primary determinant of agility performance. The purpose of this study was to investigate the relationship between knee flexor and extensor strength parameters and a battery of agility tests. Controlled laboratory study. Nineteen recreational intermittent games players completed an agility battery and isokinetic testing of the eccentric knee flexors (eccH) and concentric knee extensors (conQ) at 60, 180 and 300°·s -1 . Peak torque and the angle at which peak torque occurred were calculated for eccH and conQ at each speed. Dynamic control ratios (eccH:conQ) and fast:slow ratios (300:60) were calculated using peak torque values, and again using angle-matched data, for eccH and conQ. The agility test battery differentiated linear vs directional changes and prescriptive vs reactive tasks. Linear regression showed that eccH parameters were generally a better predictor of agility performance than conQ parameters. Stepwise regression showed that only angle-matched strength ratios contributed to the prediction of each agility test. Trdaitionally calculated strength ratios using peak torque values failed to predict performance. Angle-matched strength parameters were able to account for 80% of the variation in T-test performance, 70% of deceleration distance, 55% of 10m sprint performance, and 44% of reactive change of direction speed. Traditionally calculated strength ratios failed to predict agility performance, whereas angle-matched strength ratios had better predictive ability and featured in a predictive stepwise model for each agility task. 2c.

  17. Dependency of Shear Strength on Test Rate in SiC/BSAS Ceramic Matrix Composite at Elevated Temperature

    Science.gov (United States)

    Choi, Sung R.; Bansal, Narottam P.; Gyekenyesi, John P.

    2003-01-01

    Both interlaminar and in-plane shear strengths of a unidirectional Hi-Nicalon(TM) fiber-reinforced barium strontium aluminosilicate (SiC/BSAS) composite were determined at 1100 C in air as a function of test rate using double notch shear test specimens. The composite exhibited a significant effect of test rate on shear strength, regardless of orientation which was either in interlaminar or in in-plane direction, resulting in an appreciable shear-strength degradation of about 50 percent as test rate decreased from 3.3 10(exp -1) mm/s to 3.3 10(exp -5) mm/s. The rate dependency of composite's shear strength was very similar to that of ultimate tensile strength at 1100 C observed in a similar composite (2-D SiC/BSAS) in which tensile strength decreased by about 60 percent when test rate varied from the highest (5 MPa/s) to the lowest (0.005 MPa/s). A phenomenological, power-law slow crack growth formulation was proposed and formulated to account for the rate dependency of shear strength of the composite.

  18. 49 CFR 192.505 - Strength test requirements for steel pipeline to operate at a hoop stress of 30 percent or more...

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Strength test requirements for steel pipeline to...: MINIMUM FEDERAL SAFETY STANDARDS Test Requirements § 192.505 Strength test requirements for steel pipeline... as provided in paragraph (e) of this section, the strength test must be conducted by maintaining the...

  19. Intra-tester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.

    Science.gov (United States)

    Brindle, Richard A; Ebaugh, D David; Milner, Clare E

    2017-11-15

    Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a 'break' test the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower. To determine intra-rater reliability and construct validity of a hip abductor eccentric strength test. Intra-rater reliability and construct validity study. Twenty healthy adults (26 ±6 years; 1.66 ±0.06 m; 62.2 ±8.0 kg) made two visits to the laboratory at least one week apart. During the hip abductor eccentric strength test, a hand-held dynamometer recorded peak force and time to peak force and limb position was recorded via a motion capture system. Intra-rater reliability was determined using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable difference (MDD). Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a one-sample t-test. The hip abductor eccentric strength test had substantial intra-rater reliability (ICC( 3,3 ) = 0.88; 95% confidence interval: 0.65-0.95), SEM of 0.9%BWh, and a MDD of 2.5%BWh. Construct validity was established as peak force occurred 2.1s (±0.6s; range 0.7s to 3.7s) after the start of the lowering phase of the test (p ≤ 0.001). The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.

  20. Relationship between surface area for adhesion and tensile bond strength--evaluation of a micro-tensile bond test.

    Science.gov (United States)

    Sano, H; Shono, T; Sonoda, H; Takatsu, T; Ciucchi, B; Carvalho, R; Pashley, D H

    1994-07-01

    The purpose of this study was to test the null hypothesis that there is no relationship between the bonded surface area of dentin and the tensile strength of adhesive materials. The enamel was removed from the occlusal surface of extracted human third molars, and the entire flat surface was covered with resin composite bonded to the dentin to form a flat resin composite crown. Twenty-four hours later, the bonded specimens were sectioned parallel to the long axis of the tooth into 10-20 thin sections whose upper part was composed of resin composite with the lower half being dentin. These small sections were trimmed using a high speed diamond bur into an hourglass shape with the narrowest portion at the bonded interface. Surface area was varied by altering the specimen thickness and width. Tensile bond strength was measured using custom-made grips in a universal testing machine. Tensile bond strength was inversely related to bonded surface area. At surface areas below 0.4 mm2, the tensile bond strengths were about 55 MPa for Clearfil Liner Bond 2 (Kuraray Co., Ltd.), 38 MPa for Scotchbond MP (3M Dental Products), and 20 MPa for Vitremer (3M Dental Products). At these small surface areas all of the bond failures were adhesive in nature. This new method permits measurement of high bond strengths without cohesive failure of dentin. It also permits multiple measurements to be made within a single tooth.

  1. Porosimetric, Thermal and Strength Tests of Aerated and Nonaerated Concretes

    Science.gov (United States)

    Strzałkowski, Jarosław; Garbalińska, Halina

    2017-10-01

    The paper presents the results of porosimetry tests of lightweight concretes, obtained with three research methods. Impact of different porosity structures on the basic thermal and strength properties was also evaluated. Tests were performed, using the pressure gauge method on fresh concrete mixes, as well as using the mercury porosimetry test and optic RapidAir method on specimens prepared from mature composites. The study was conducted on lightweight concretes, based on expanded clay aggregate and fly ash aggregate, in two variants: with non-aerated and aerated cement matrix. In addition, two reference concretes, based on normal aggregate, were prepared, also in two variants of matrix aeration. Changes in thermal conductivity λ and volumetric specific heat cv throughout the first three months of curing of the concretes were examined. Additionally, tests for compressive strength on cubic samples were performed during the first three months of curing. It was found that the pressure gauge method, performed on a fresh mix, gave lowered values of porosity, compared to the other methods. The mercury porosity tests showed high sensitivity in evaluation of pores smaller than 30μm. Unfortunately, this technique is not suitable for analysing pores greater than 300μm. On the other hand, the optical method proves good in evaluation of large pores, greater than 300μm. The paper also presents results of correlation of individual methods of porosity testing. A consolidated graph of the pore structure, derived from both mercury and optical methods, was presented, too. For the all of six tested concretes, differential graphs of porosity, prepared with both methods, show a very broad convergence. The thermal test results indicate usefulness of aeration of the cement matrix of the composites based on lightweight aggregates for the further reduction of the thermal conductivity coefficient λ of the materials. The lowest values of the λ coefficient were obtained for the aerated

  2. Practicing the Test Produces Strength Equivalent to Higher Volume Training.

    Science.gov (United States)

    Mattocks, Kevin T; Buckner, Samuel L; Jessee, Matthew B; Dankel, Scott J; Mouser, J Grant; Loenneke, Jeremy P

    2017-09-01

    To determine if muscle growth is important for increasing muscle strength or if changes in strength can be entirely explained from practicing the strength test. Thirty-eight untrained individuals performed knee extension and chest press exercise for 8 wk. Individuals were randomly assigned to either a high-volume training group (HYPER) or a group just performing the one repetition maximum (1RM) strength test (TEST). The HYPER group performed four sets to volitional failure (~8RM-12RM), whereas the TEST group performed up to five attempts to lift as much weight as possible one time each visit. Data are presented as mean (90% confidence interval). The change in muscle size was greater in the HYPER group for both the upper and lower bodies at most but not all sites. The change in 1RM strength for both the upper body (difference of -1.1 [-4.8, 2.4] kg) and lower body (difference of 1.0 [-0.7, 2.8] kg for dominant leg) was not different between groups (similar for nondominant). Changes in isometric and isokinetic torque were not different between groups. The HYPER group observed a greater change in muscular endurance (difference of 2 [1,4] repetitions) only in the dominant leg. There were no differences in the change between groups in upper body endurance. There were between-group differences for exercise volume (mean [95% confidence interval]) of the dominant (difference of 11,049.3 [9254.6-12,844.0] kg) leg (similar for nondominant) and chest press with the HYPER group completing significantly more total volume (difference of 13259.9 [9632.0-16,887.8] kg). These findings suggest that neither exercise volume nor the change in muscle size from training contributed to greater strength gains compared with just practicing the test.

  3. Fatigue testing of weldable high strength steels under simulated service conditions

    Science.gov (United States)

    Tantbirojn, Natee

    There have been concerns over the effect of Cathodic Protection (CP) on weldable high strength steels employed in Jack-up production platform. The guidance provided by the Department of Energy HSE on higher strength steels, based on previous work, was to avoid overprotection as this could cause hydrogen embrittlement. However, the tests conducted so far at UCL for the SE702 type high strength steels (yields strength around 690 MPa) have shown that the effect of over protection on high strength steels may not be as severe as previously thought. For this thesis, SE702 high strength steels have been investigated in more detail. Thick (85mm) parent and ground welded plates were tested under constant amplitude in air and seawater with CP. Tests were also conducted on Thick (40mm) T-butt welded plates under variable amplitude loading in air and seawater with two CP levels (-800mV and -1050mV). Different backing materials (ceramic and metallic) for the welding process of the T-butt plates were also investigated. The variable amplitude sequences employed were generated using the Jack-up Offshore Standard load History (JOSH). The fatigue results are presented as crack growth and S/N curves. They were compared to the conventional offshore steel (BS 4360 50D). The results suggested that the fatigue life of the high strength steels was comparable to the BS 4360 50D steels. The effect of increasing the CP was found to be detrimental to the fatigue life but the effect was not large. The effect of CP was less noticeable in T-butt welded plates. However, in general, the effect of overprotection is not as detrimental to the Jack-up steels as previously thought. The load histories generated by JOSH were found to have some unfavourable characteristics. The framework is based on Markov Chain method and pseudo-random number generator for selecting sea-states. A study was carried out on the sequence generated by JOSH. The generated sequences were analysed for their validity for fatigue

  4. Impact of pain reported during isometric quadriceps muscle strength testing in people with knee pain: data from the osteoarthritis initiative.

    Science.gov (United States)

    Riddle, Daniel L; Stratford, Paul W

    2011-10-01

    Muscle force testing is one of the more common categories of diagnostic tests used in clinical practice. Clinicians have little evidence to guide interpretations of muscle force tests when pain is elicited during testing. The purpose of this study was to examine the construct validity of isometric quadriceps muscle strength tests by determining whether the relationship between maximal isometric quadriceps muscle strength and functional status was influenced by pain during isometric testing. A cross-sectional design was used. Data from the Osteoarthritis Initiative were used to identify 1,344 people with unilateral knee pain and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain subscale scores of 1 or higher on the involved side. Measurements of maximal isometric quadriceps strength and ratings of pain during isometric testing were collected. Outcome variables were WOMAC physical function subscale, 20-m walk test, 400-m walk test, and a repeated chair stand test. Multiple regression models were used to determine whether pain during testing modified or confounded the relationship between strength and functional status. Pearson r correlations among the isometric quadriceps strength measures and the 4 outcome measures ranged from -.36 (95% confidence interval=-.41, -.31) for repeated chair stands to .36 (95% confidence interval=.31, .41) for the 20-m walk test. In the final analyses, neither effect modification nor confounding was found for the repeated chair stand test, the 20-m walk test, the 400-m walk test, or the WOMAC physical function subscale. Moderate or severe pain during testing was weakly associated with reduced strength, but mild pain was not. The disease spectrum was skewed toward mild or moderate symptoms, and the pain measurement scale used during muscle force testing was not ideal. Given that the spectrum of the sample was skewed toward mild or moderate symptoms and disease, the data suggest that isometric quadriceps muscle

  5. Validity and reliability of the 10-m walk test and the 6-min walk test in spinal cord injury patients.

    Science.gov (United States)

    Scivoletto, G; Tamburella, F; Laurenza, L; Foti, C; Ditunno, J F; Molinari, M

    2011-06-01

    The 10-m walk test (10MWT) and the 6-min walk test (6MWT) have been recommended for assessment of walking in spinal cord injury (SCI) patients. The study was designed on test-retest analysis of the 10MWT and 6MWT. The objective of this study was to assess validity/reliability of different methods of performing the tests. The study was set at an SCI unit of a rehabilitation hospital. A total of 37 patients; whose median age was 58.5 years (interquartile range 40-66, full range 19-77); median time since onset of SCI was 24 months (interquartile range 16.25-70.5, full range 6-109). Non-traumatic etiology in 20 out of 37 patients; level: 12C, 14T and 11L; American Spinal Injury Association Impairment Scale grade: 35D/2C. Assessment with the 10MWT (with or without dynamic start) and the 6MWT (short or long track) by two blinded raters to evaluate inter/intra-rater reliabilities. The 10MWT was performed in a median of 19 s (25th-75th interquartile range 13-28) with the dynamic start and of 18.4 s (25th-75th interquartile range 12.6-29.9) with the static start (P=0.092). The correlation between the results of the two methods was between 0.98 and 0.99. The inter- and intra-rater reliabilities were between 0.95 and 0.99 for both the methods. The 6MWT showed significant differences according to the track length: patients walked a median of 226.7 m (25th-75th interquartile range 123.2-319) on the longer track and of 187.6 m (25th-75th interquartile range 69.7-240.6) on the short one (P<0.001). The correlation between the results of the two methods was between 0.91 and 0.93. The inter- and intra-rater reliabilities were between 0.98 and 0.99. The 10MWT shows high inter/intra-rater reliability and shows comparable results with both dynamic and static start. The different testing conditions of the 6MWT (track/turns) results in significant differences that need standardization for use in future trials.

  6. Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

    Science.gov (United States)

    Laughlin, Mitzi S.; Lee, Stuart M. C.; Loehr, James A.; Amonette, William E.

    2009-01-01

    To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

  7. Single-Leg Hop Test Performance and Isokinetic Knee Strength After Anterior Cruciate Ligament Reconstruction in Athletes.

    Science.gov (United States)

    Sueyoshi, Ted; Nakahata, Akihiro; Emoto, Gen; Yuasa, Tomoki

    2017-11-01

    Isokinetic strength and hop tests are commonly used to assess athletes' readiness to return to sport after knee surgery. The purpose of this study was to investigate the results of single-leg hop and isokinetic knee strength testing in athletes who underwent anterior cruciate ligament reconstruction (ACLR) upon returning to sport participation as well as to study the correlation between these 2 test batteries. The secondary purpose was to compare the test results by graft type (patellar tendon or hamstring). It was hypothesized that there would be no statistically significant limb difference in either isokinetic knee strength or single-leg hop tests, that there would be a moderate to strong correlation between the 2 test batteries, and that there would be no significant difference between graft types. Cross-sectional study; Level of evidence, 3. Twenty-nine high school and collegiate athletes who underwent ACLR participated in this study. At the time of return to full sport participation, a series of hop tests and knee extension/flexion isokinetic strength measurements were conducted. The results were analyzed using analysis of variance and Pearson correlation ( r ). The timed 6-m hop test was the only hop test that showed a significant difference between the involved and uninvolved limbs (2.3 and 2.2 seconds, respectively; P = .02). A significant difference between limbs in knee strength was found for flexion peak torque/body weight at 180 deg/s ( P = .03), flexion total work/body weight at 180 deg/s ( P = .04), and flexion peak torque/body weight at 300 deg/s ( P = .03). The strongest correlation between the hop tests and knee strength was found between the total distance of the hop tests and flexion total work/body weight at 300 deg/s ( r = 0.69) and between the timed 6-m hop test and flexion peak torque/body weight at 300 deg/s ( r = -0.54). There was no statistically significant difference in hop test performance or isokinetic knee strength between graft types

  8. Development of micro tensile testing method in an FIB system for evaluating grain boundary strength

    International Nuclear Information System (INIS)

    Fujii, Katsuhiko; Fukuya, Koji

    2010-01-01

    A micro tensile testing method for evaluating grain boundary strength was developed. Specimens of 2 x 2 x 10μm having one grain boundary were made by focused ion beam (FIB) micro-processing and tensioned in an FIB system in situ. The load was measured from the deflection of the silicon cantilever. The method was applied to aged and unaged Fe-Mn-P alloy specimens with different level of grain boundary phosphorus segregation. The load at intergranular fracture decreased with increasing phosphorus segregation. (author)

  9. Coenzyme Q10 Status as a Determinant of Muscular Strength in Two Independent Cohorts.

    Directory of Open Access Journals (Sweden)

    Alexandra Fischer

    Full Text Available Aging is associated with sarcopenia, which is a loss of skeletal muscle mass and function. Coenzyme Q10 (CoQ10 is involved in several important functions that are related to bioenergetics and protection against oxidative damage; however, the role of CoQ10 as a determinant of muscular strength is not well documented. The aim of the present study was to evaluate the determinants of muscular strength by examining hand grip force in relation to CoQ10 status, gender, age and body mass index (BMI in two independent cohorts (n = 334, n = 967. Furthermore, peak flow as a function of respiratory muscle force was assessed. Spearman's correlation revealed a significant positive association between CoQ10/cholesterol level and hand grip in the basic study population (p<0.01 as well as in the validation population (p<0.001. In the latter, we also found a negative correlation with the CoQ10 redox state (p<0.01, which represents a lower percentage of the reduced form of CoQ10 (ubiquinol in subjects who exhibit a lower muscular strength. Furthermore, the age of the subjects showed a negative correlation with hand grip (p<0.001, whereas BMI was positively correlated with hand grip (p<0.01, although only in the normal weight subgroup (BMI <25 kg/m2. Analysis of the covariance (ANCOVA with hand grip as the dependent variable revealed CoQ10/cholesterol as a determinant of muscular strength and gender as the strongest effector of hand grip. In conclusion, our data suggest that both a low CoQ10/cholesterol level and a low percentage of the reduced form of CoQ10 could be an indicator of an increased risk of sarcopenia in humans due to their negative associations to upper body muscle strength, peak flow and muscle mass.

  10. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers.

    Science.gov (United States)

    Alp, Gülce; Murat, Sema; Yilmaz, Burak

    2018-01-28

    To compare the flexural strength of different computer-aided design/computer-aided manufacturing (CAD/CAM) poly(methyl methacrylate)-based (PMMA) polymers and conventional interim resin materials after thermocycling. Rectangular-shaped specimens (n = 15, for each material) (25 × 2 × 2 mm 3 ) were fabricated from 3 CAD/CAM PMMA-based polymers (Telio CAD [T]; M-PM-Disc [M]; Polident-PMMA [P]), 1 bis-acrylate composite resin (Protemp 4 [PT]), and 1 conventional PMMA (ArtConcept Artegral Dentine [C]) according to ISO 10477:2004 Standards (Dentistry-Polymer-Based Crown and Bridge Materials). The specimens were subjected to 10,000 thermocycles (5 to 55°C). Three-point flexural strength of the specimens was tested in a universal testing machine at a 1.0 mm/min crosshead speed, and the flexural strength data (σ) were calculated (MPa). The flexural strength values were statistically analyzed using 1-way ANOVA, and Tukey HSD post-hoc test for multiple comparisons (α = 0.05). Flexural strength values ranged between 66.1 ± 13.1 and 131.9 ± 19.8 MPa. There were significant differences among the flexural strengths of tested materials, except for between T and P CAD/CAM PMMA-based polymers (p > 0.05). CAD/CAM PMMA-based polymer M had the highest flexural strength and conventional PMMA had the lowest (p CAD/CAM PMMA-based T and P polymers had significantly higher flexural strength than the bis-acrylate composite resin (p CAD/CAM PMMA-based M (p CAD/CAM PMMA-based polymers was greater than the flexural strength of bis-acrylate composite resin, which had a greater flexural strength compared to conventional PMMA resin. © 2018 by the American College of Prosthodontists.

  11. Sustainable normal and high strength recycled aggregate concretes using crushed tested cylinders as coarse aggregates

    Directory of Open Access Journals (Sweden)

    Bilal S. Hamad

    2017-12-01

    Full Text Available The paper reports on a research program that was designed at the American University of Beirut (AUB to investigate the fresh and hardened mechanical properties of a high performance concrete mix produced with partial or full substitution of crushed natural lime-stone aggregates with recycled aggregates from crushed tested cylinders in batching plants. Choosing crushed cylinders as source of recycling would result in reusing portion of the waste products of the concrete production industry. An extensive concrete batching and testing program was conducted to achieve two optimum normal and high strength concrete mixes. The variables were the nominal concrete strength (28 or 60 MPa and the percentage replacement of natural coarse aggregates with recycled aggregates from crushed tested cylinders (0, 20, 40, 60, 80, or 100%. Normal strength tested cylinders were used as source of the recycled aggregates for the normal strength concrete (NSC mix and high strength tested cylinders were used for the high strength concrete (HSC mix. Tests on the trial batches included plastic state slump and hardened state mechanical properties including cylinder compressive strength, cylinder splitting tensile strength, modulus of elasticity, and standard beams flexural strength. The results indicated no significant effect on the slump and around 10% average reduction in the hardened mechanical properties for both investigated levels of concrete compressive strength.

  12. Dentin-composite bond strength measurement using the Brazilian disk test.

    Science.gov (United States)

    Carrera, Carola A; Chen, Yung-Chung; Li, Yuping; Rudney, Joel; Aparicio, Conrado; Fok, Alex

    2016-09-01

    This study presents a variant of the Brazilian disk test (BDT) for assessing the bond strength between composite resins and dentin. Dentin-composite disks (ϕ 5mm×2mm) were prepared using either Z100 or Z250 (3M ESPE) in combination with one of three adhesives, Adper Easy Bond (EB), Adper Scotchbond Multi-Purpose (MP) and Adper Single Bond (SB), and tested under diametral compression. Acoustic emission (AE) and digital image correlation (DIC) were used to monitor debonding of the composite from the dentin ring. A finite element (FE) model was created to calculate the bond strengths using the failure loads. Fracture modes were examined by scanning electron microscopy (SEM). Most specimens fractured along the dentin-resin composite interface. DIC and AE confirmed interfacial debonding immediately before fracture of the dentin ring. Results showed that the mean bond strength with EB (14.9±1.9MPa) was significantly higher than with MP (13.2±2.4MPa) or SB (12.9±3.0MPa) (p0.05). Z100 (14.5±2.3MPa) showed higher bond strength than Z250 (12.7±2.5MPa) (pstrength between dentin and composite, with zero premature failure, reduced variability in the measurements, and consistent failure at the dentin-composite interface. The new test could help to predict the clinical performance of adhesive systems more effectively and consistently by reducing the coefficient of variation in the measured bond strength. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain: What are the Clinical Implications of Pain During Testing?

    Science.gov (United States)

    Rafn, Bolette S; Tang, Lars; Nielsen, Martin P; Branci, Sonia; Hölmich, Per; Thorborg, Kristian

    2016-05-01

    To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. Cross-sectional study. Clinical assessments at Sports Orthopaedic Research Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. Twenty-four male soccer players with unilateral long-standing hip and groin pain. The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion, adduction, abduction, isometric hip flexion-modified Thomas test, and eccentric hip adduction). Muscle strength was measured with a hand-held dynamometer, and the players rated the pain during testing on a numerical rating scale (0-10). In 4 tests (isometric hip adduction, abduction, flexion, and eccentric adduction), no significant correlations were found between pain during testing and hip muscle strength (Spearman rho = -0.28 to 0.06, P = 0.09-0.39). Isometric hip flexion (modified Thomas test position) showed a moderate negative correlation between pain and hip muscle strength (Spearman rho = -0.44, P = 0.016). Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain.

  14. Translucent zirconia in the ceramic scenario for monolithic restorations: A flexural strength and translucency comparison test.

    Science.gov (United States)

    Carrabba, Michele; Keeling, Andrew J; Aziz, Aziz; Vichi, Alessandro; Fabian Fonzar, Riccardo; Wood, David; Ferrari, Marco

    2017-05-01

    To compare three different compositions of Yttria-Tetragonal Zirconia Polycrystal (Y-TZP) ceramic and a lithium disilicate ceramic in terms of flexural strength and translucency. Three zirconia materials of different composition and translucency, Aadva ST [ST], Aadva EI [EI] and Aadva NT [NT](GC Tech, Leuven, Belgium) were cut with a slow speed diamond saw into beams and tabs in order to obtain, after sintering, dimensions of 1.2×4.0×15.0mm and 15.0×15.0×1.0mm respectively. Blocks of IPS e.max CAD LT were cut and crystallized in the same shapes and dimensions and used as a reference group [LD]. Beams (n=15) were tested in a universal testing machine for three-point bending strength. Critical fracture load was recorded in N, flexural strength (σ in MPa), Weibull modulus (m) and Weibull characteristic strength (σ 0 in MPa) were then calculated. Tabs (n=10) were measured with a spectrophotometer equipped with an integrating sphere. Contrast Ratios were calculated as CR=Yb/Yw. SEM of thermally etched samples coupled with lineal line analysis (n=6) was used to measure the tested zirconia grain size. Data were statistically analyzed. Differences in translucency, flexural strength and grain size were found to be statistically significant. CR increased and flexural strength decreased in the following order ST(σ 1215±190MPa, CR 0.74±0.01)>EI(σ 983±182MPa, CR 0.69±0.01)>NT(σ 539±66MPa, CR 0.65±0.01)>LD (σ 377±39Mpa, CR 0.56±0.02). The average grain size was different for the three zirconia samples with NT(558±38nm)>ST(445±34nm)>EI(284±11nm). The zirconia composition heavily influenced both the flexural strength and the translucency. Different percentages of Yittria and Alumina result in new materials with intermediate properties in between the conventional zirconia and lithium disilicate. Clinical indications for Zirconia Aadva NT should be limited up to three-unit span bridges. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Strength of 10CR-N martensitic steels

    International Nuclear Information System (INIS)

    Bahrami, F.; Hendry, A.

    1993-01-01

    10Cr stainless steel has been employed to examine the effect of nitrogen on microstructure and strength. Applying Solid state gaseous nitrogenising treatments a whole range of nitrogen martensite structures containing up to 0.45 wt% were obtained. It was found that a linear relationship exists between strength and nitrogen content in precipitate free martensitic structures. Yield strength increased from 705 to 1295 MPa for nitrogen free base material and alloys with 0.35 wt%N respectively. Pronounce secondary hardening was observed at a tempering temperature of 500 C. A linear relationship was also observed between the lattice parameter and nitrogen concentration in these alloys. A model for mechanical behaviour is presented. (orig.)

  16. Strength cues and blocking at test promote reliable within-list criterion shifts in recognition memory.

    Science.gov (United States)

    Hicks, Jason L; Starns, Jeffrey J

    2014-07-01

    In seven experiments, we explored the potential for strength-based, within-list criterion shifts in recognition memory. People studied a mix of target words, some presented four times (strong) and others studied once (weak). In Experiments 1, 2, 4A, and 4B, the test was organized into alternating blocks of 10, 20, or 40 trials. Each block contained lures intermixed with strong targets only or weak targets only. In strength-cued conditions, test probes appeared in a unique font color for strong and weak blocks. In the uncued conditions of Experiments 1 and 2, similar strength blocks were tested, but strength was not cued with font color. False alarms to lures were lower in blocks containing strong target words, as compared with lures in blocks containing weak targets, but only when strength was cued with font color. Providing test feedback in Experiment 2 did not alter these results. In Experiments 3A-3C, test items were presented in a random order (i.e., not blocked by strength). Of these three experiments, only one demonstrated a significant shift even though strength cues were provided. Overall, the criterion shift was larger and more reliable as block size increased, and the shift occurred only when strength was cued with font color. These results clarify the factors that affect participants' willingness to change their response criterion within a test list.

  17. Orthodontic brackets removal under shear and tensile bond strength resistance tests - a comparative test between light sources

    Science.gov (United States)

    Silva, P. C. G.; Porto-Neto, S. T.; Lizarelli, R. F. Z.; Bagnato, V. S.

    2008-03-01

    We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 ± 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

  18. High-Strength Composite Fabric Tested at Structural Benchmark Test Facility

    Science.gov (United States)

    Krause, David L.

    2002-01-01

    Large sheets of ultrahigh strength fabric were put to the test at NASA Glenn Research Center's Structural Benchmark Test Facility. The material was stretched like a snare drum head until the last ounce of strength was reached, when it burst with a cacophonous release of tension. Along the way, the 3-ft square samples were also pulled, warped, tweaked, pinched, and yanked to predict the material's physical reactions to the many loads that it will experience during its proposed use. The material tested was a unique multi-ply composite fabric, reinforced with fibers that had a tensile strength eight times that of common carbon steel. The fiber plies were oriented at 0 and 90 to provide great membrane stiffness, as well as oriented at 45 to provide an unusually high resistance to shear distortion. The fabric's heritage is in astronaut space suits and other NASA programs.

  19. Reflector dowel strength test, Fort St. Vrain

    International Nuclear Information System (INIS)

    Doll, D.W.

    1975-01-01

    The strength of the 44.45 mm (1.75 in.) diameter Fort St. Vrain (FSV) reflector dowel for loads directed radially inward toward the center of the element was measured. For a statically applied load, the strength exceeded 5783 N (1300 lb) in direct shear. This strength remained after load cycling 100 times to 4448 N (1000 lb), 10 times to 4893 N (1100 lb), 10 times to 5338 N (1200 lb), and two times to 5783 N (1300 lb). Typically, the deflection to ultimate failure was approximately 1.0 mm (0.04 in.). At about 3316 N (750 lb) and 0.20 mm (0.008 in.) deflection, one of the webs between the dowel and a coolant hole cracked, apparently redistributing the load. No further failure occurred up to the ultimate load of 5783+ N (1300+ lb)

  20. Study on strength characteristics of concrete using M-Sand and coconut fibers

    Science.gov (United States)

    Neeraja, D.; Wani, Amir Iqbal; Kamili, Zainulabideen; Agarwal, Krishnakant

    2017-11-01

    In the current world, concrete has become a very important part of the construction industry and the materials which are used in making concrete have evolved due to better quality of cement and better grade of coarse aggregates. The sand is an important part of concrete. It is mainly procured from natural sources. Thus the grade of sand is not under our control. The methods of removing sand from river beds are causing various environmental issues and river sand is depleting at a faster rate than it is replaced by natural methods. Hence, various replacements for the river sand are being done, one of which is manufactured-sand. It is obtained from various granite quarries. Manufactured-sand or M-sand is slowly replacing the fine aggregate in the concrete as the sand is well graded and gives higher strength of concrete. There are various fibers used for reinforcing concrete which consist mainly of artificial or steel fibers. Some of these fibers are quite costly and sometimes difficult to obtain. So there are many natural fibers which can be used in place of these fibers, one of which is coconut fiber, extracted from the shell of a coconut. Coconut fibers are used in various industries like rope making, coir mattresses etc. Since these fibers are one of the strongest fibers among naturally occuring fibers, they can be used in the concrete mix to increase the resistance in concrete. They are also light weight and easily available and thus can be used in reinforcement of concrete. The studies up till now have tested the use of coconut fibers in normal concrete involving river sand but in this study a particular ratio of M-sand and river sand is used to get the maximum possible strength. Hence, in this project an attempt was made to use M-sand and coconut fiber in concrete. Based on the test results, it can be concluded that combination of M-sand and coconut fibers gave favorable results in strength criteria.

  1. The Relationship Between Hip Strength and the Y-Balance Test.

    Science.gov (United States)

    Wilson, Benjamin R; Robertson, Kaley E; Burnham, Jeremy M; Yonz, Michael C; Ireland, Mary Lloyd; Noehren, Brian

    2017-07-17

    The Y-Balance Test was developed as a test of dynamic postural control and has been shown to be predictive of lower extremity injury. However, the relationship between hip strength and performance on the Y-Balance Test has not been fully elucidated. The goal of this study was to identify the relationship between components of isometric hip strength and the Y-Balance Test, to provide clinicians better guidance as to specific areas of muscle performance to address in the event of poor performance on the Y-Balance Test. Laboratory Study. Biomechanics Laboratory. Seventy-three healthy participants, 40 males and 33 females, volunteered for this study. None. Participants completed the Y-Balance Test on the right leg. We then measured peak isometric torque in hip external rotation, abduction, and extension. Correlations were calculated between torque measurements, normalized for mass, and Y-Balance Test performance. Significant relationships were used in linear regression models to determine which variables were predictive of the Y-Balance Test performance. We found significant positive correlations between Y-Balance Test performance and hip abduction strength. We also found correlations between the Y-Balance Test and hip extension and external rotation strengths. Linear regression analysis showed hip abduction to be the only significant predictor of Y- Balance performance. We found the strongest association between the Y-Balance Test and hip abduction strength. We also showed smaller but significant associations with hip extension and external rotation strength. When entered into a linear regression analysis, hip abduction strength was the only significant predictor of Y-Balance performance. Using this information, practitioners should look to hip abduction strength when patients exhibit deficits in the Y-Balance Test.

  2. Validity and test-retest reliability of a novel simple back extensor muscle strength test.

    Science.gov (United States)

    Harding, Amy T; Weeks, Benjamin Kurt; Horan, Sean A; Little, Andrew; Watson, Steven L; Beck, Belinda Ruth

    2017-01-01

    To develop and determine convergent validity and reliability of a simple and inexpensive clinical test to quantify back extensor muscle strength. Two testing sessions were conducted, 7 days apart. Each session involved three trials of standing maximal isometric back extensor muscle strength using both the novel test and isokinetic dynamometry. Lumbar spine bone mineral density was examined by dual-energy X-ray absorptiometry. Validation was examined with Pearson correlations ( r ). Test-retest reliability was examined with intraclass correlation coefficients and limits of agreement. Pearson correlations and intraclass correlation coefficients are presented with corresponding 95% confidence intervals. Linear regression was used to examine the ability of peak back extensor muscle strength to predict indices of lumbar spine bone mineral density and strength. A total of 52 healthy adults (26 men, 26 women) aged 46.4 ± 20.4 years were recruited from the community. A strong positive relationship was observed between peak back extensor strength from hand-held and isokinetic dynamometry ( r  = 0.824, p  strength test, short- and long-term reliability was excellent (intraclass correlation coefficient = 0.983 (95% confidence interval, 0.971-0.990), p  strength measures with the novel back extensor strength protocol were -6.63 to 7.70 kg, with a mean bias of +0.71 kg. Back extensor strength predicted 11% of variance in lumbar spine bone mineral density ( p  strength ( p  strength is quick, relatively inexpensive, and reliable; demonstrates initial convergent validity in a healthy population; and is associated with bone mass at a clinically important site.

  3. Strength of mortar containing rubber tire particle

    Science.gov (United States)

    Jusoh, M. A.; Abdullah, S. R.; Adnan, S. H.

    2018-04-01

    The main focus in this investigation is to determine the strength consist compressive and tensile strength of mortar containing rubber tire particle. In fact, from the previous study, the strength of mortar containing waste rubber tire in mortar has a slightly decreases compare to normal mortar. In this study, rubber tire particle was replacing on volume of fine aggregate with 6%. 9% and 12%. The sample were indicated M0 (0%), M6 (6%), M9 (9%) and M12 (12%). In this study, two different size of sample used with cube 100mm x 100mm x 100mm for compressive strength and 40mm x 40mm x 160mm for flexural strength. Morphology test was conducted by using Scanning electron microscopic (SEM) were done after testing compressive strength test. The concrete sample were cured for day 3, 7 and 28 before testing. Results compressive strength and flexural strength of rubber mortar shown improved compare to normal mortar.

  4. Stud-bolts strength for cell-liner design under shearing deformation

    International Nuclear Information System (INIS)

    Watashi, Katsumi; Nakanishi, Seiji

    1991-01-01

    This paper presents experimental and analytical stud-bolt strength subjected to large shearing deformation at high temperature. Tensile test result of the material, SM41B, was shown in the range of room temperature to 550degC at 10 -3 and 10 -4 m/m/s in strain rate. Shearing fracture test result of the stud-bolt is shown at room temperature and 530degC. Shearing fracture criterion was discussed based on both test results and FEM analysis result. (author)

  5. A comparison of maximal squat strength and 5-, 10-, and 20-meter sprint times, in athletes and recreationally trained men.

    Science.gov (United States)

    Comfort, Paul; Bullock, Nathan; Pearson, Stephen J

    2012-04-01

    The purpose of this study was to identify whether there was a relationship between relative strength during a 1 repetition maximum (1RM) back squat and 5-, 10-, and 20-m sprint performances in both trained athletes and recreationally trained individuals. Professional rugby league players (n = 24) and recreationally trained individuals (n = 20) participated in this investigation. Twenty-meter sprint time and 1RM back squat strength, using free weights, were assessed on different days. There were no significant (p ≥ 0.05) differences between the well-trained and recreationally trained groups for 5-m sprint times. In contrast, the well-trained group's 10- and 20-m sprint times were significantly quicker (p = 0.004; p = 0.002) (1.78 + 0.06 seconds; 3.03 + 0.09 seconds) compared with the recreationally trained group (1.84 + 0.07 seconds; 3.13 + 0.11 seconds). The athletes were significantly stronger (170.63 + 21.43 kg) than the recreationally trained individuals (135.45 + 30.07 kg) (p = 0.01); however, there were no significant differences (p > 0.05) in relative strength between groups (1.78 + 0.27 kg/kg; 1.78 + 0.33 kg/kg, respectively). Significant negative correlations were found between 5-m sprint time and relative squat strength (r = -0.613, power = 0.96, p = 0.004) and between relative squat strength and 10- and 20-m sprint times in the recreationally trained group (r = -0.621, power = 0.51, p = 0.003; r = -0.604, power = 0.53, p = 0.005, respectively). These results, indicating that relative strength, are important for initial sprint acceleration in all athletes but more strongly related to sprint performance over greater distances in recreationally trained individuals.

  6. Strength Testing in Motor Neuron Diseases.

    Science.gov (United States)

    Shefner, Jeremy M

    2017-01-01

    Loss of muscle strength is a cardinal feature of all motor neuron diseases. Functional loss over time, including respiratory dysfunction, inability to ambulate, loss of ability to perform activities of daily living, and others are due, in large part, to decline in strength. Thus, the accurate measurement of limb muscle strength is essential in therapeutic trials to best understand the impact of therapy on vital function. While qualitative strength measurements show declines over time, the lack of reproducibility and linearity of measurement make qualitative techniques inadequate. A variety of quantitative measures have been developed; all have both positive attributes and limitations. However, with careful training and reliability testing, quantitative measures have proven to be reliable and sensitive indicators of both disease progression and the impact of experimental therapy. Quantitative strength measurements have demonstrated potentially important therapeutic effects in both amyotrophic lateral sclerosis and spinobulbar muscular atrophy, and have been shown feasible in children with spinal muscular atrophy. The spectrum of both qualitative and quantitative strength measurements are reviewed and their utility examined in this review.

  7. Orthodontic brackets removal under shear and tensile bond strength resistance tests – a comparative test between light sources

    International Nuclear Information System (INIS)

    Silva, P C G; Porto-Neto, S T; Lizarelli, R F Z; Bagnato, V S

    2008-01-01

    We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 ± 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased

  8. Welding of high-strength stainless steel 03Kh12N10MT for cryogenic engineering

    International Nuclear Information System (INIS)

    Pustovit, A.I.

    1989-01-01

    Consideration is being given to weld resistance to cold and hot cracking at 93 and 77K and to mechanical properties of welded joints of high-strength stainless steel 03Kh12N10MT, produced under the fluxes AN-17M, AN-18, AN-26, AN-45, ANF-5, 48-OF-6, ANK-45 and ANK-49 in combination with various welding wires. It is shown that welds on 03Kh12N10MT steel meet the requirements only when using 48-OF-6 or ANK-49 flux. It is noted that impact strength of welds at 77K is sufficiently affected by the volume fraction of non-metallic inclusions in weld metal

  9. C-130: Results of center wing residual strength and crack propagation test program

    Science.gov (United States)

    Reeder, F. L.; Dirkin, W. J.; Snider, H. L.

    1971-01-01

    Fourteen C-130 airplane center wings which had experienced from approximately 4,000 to 13,000 hours of flight service and its associated fatigue damage were tested to destruction, seven in upbending and seven in downbending. Six wings were tested directly for static residual strength in the fatigue-damaged condition as received from field service. The other eight wings were tested in crack propagation cyclic testing at a prescribed stress level for a maximum of 10,000 cycles. Then the stress level was reduced and testing was continued up to a maximum of 20,000 total cycles. Cyclic testing was performed with constant-amplitude stresses at a stress ratio of +0.1. Maximum cyclic skin stresses were approximately 18,000 psi. At the conclusion of cyclic testing, a static test to destruction was conducted to determine the residual strength of each fatigue-damaged specimen.

  10. The 1-Minute Sit-to-Stand Test in Adults With Cystic Fibrosis: Correlations With Cardiopulmonary Exercise Test, 6-Minute Walk Test, and Quadriceps Strength.

    Science.gov (United States)

    Gruet, Mathieu; Peyré-Tartaruga, Leonardo Alexandre; Mely, Laurent; Vallier, Jean-Marc

    2016-12-01

    Exercise testing is part of the regular assessment of patients with cystic fibrosis (CF). We aimed to evaluate (1) the convergent validity of the 1-min sit-to-stand (STS) test in CF by investigating its relationships with peak oxygen uptake (peak V̇ O 2 ), quadriceps strength, and quality of life and (2) to compare these associations with those of the 6-min walk test (6MWT). Twenty-five adults with CF (FEV 1 = 59 ± 24%) performed the STS test, the 6MWT, quadriceps strength assessment, and cardiopulmonary exercise test (CPET). Physical activity level, quality of life, and self-esteem were assessed by questionnaires. STS repetitions, 6-min walk distance, quadriceps strength, and peak V̇ O 2 were, respectively, 71 ± 12, 90 ± 10, 93 ± 29, and 62 ± 16% of predicted. The STS test had moderate associations with peak V̇ O 2 (r = 0.56, P = .004), quadriceps strength (r = 0.52, P = .008), and some questionnaire items (eg, perceived physical strength, r = 0.67, P test was strongly associated with oxygen desaturation during CPET (r = 0.80, P test as compared with CPET (P test cannot be used as a replacement for CPET to accurately assess peak exercise capacity in CF. The STS test may have utility in detecting patients with CF who may exhibit a high level of oxygen desaturation during heavy exercise. Further studies should identify the factors contributing to STS performance to confirm the potential interest of STS repetitions × body weight outcome as a useful submaximal exercise parameter in CF. Copyright © 2016 by Daedalus Enterprises.

  11. Shear strength characteristics of mechanically biologically treated municipal solid waste (MBT-MSW) from Bangalore

    International Nuclear Information System (INIS)

    Sivakumar Babu, G.L.; Lakshmikanthan, P.; Santhosh, L.G.

    2015-01-01

    Highlights: • Shear strength properties of mechanically biologically treated municipal solid waste. • Effect of unit weight and particle size on the shear strength of waste. • Effect of particle size on the strength properties. • Stiffness ratio and the strength ratio of MSW. - Abstract: Strength and stiffness properties of municipal solid waste (MSW) are important in landfill design. This paper presents the results of comprehensive testing of shear strength properties of mechanically biologically treated municipal solid waste (MBT-MSW) in laboratory. Changes in shear strength of MSW as a function of unit weight and particle size were investigated by performing laboratory studies on the MSW collected from Mavallipura landfill site in Bangalore. Direct shear tests, small scale and large scale consolidated undrained and drained triaxial tests were conducted on reconstituted compost reject MSW samples. The triaxial test results showed that the MSW samples exhibited a strain-hardening behaviour and the strength of MSW increased with increase in unit weight. Consolidated drained tests showed that the mobilized shear strength of the MSW increased by 40% for a unit weight increase from 7.3 kN/m 3 to 10.3 kN/m 3 at 20% strain levels. The mobilized cohesion and friction angle ranged from 5 to 9 kPa and 8° to 33° corresponding to a strain level of 20%. The consolidated undrained tests exhibited reduced friction angle values compared to the consolidated drained tests. The friction angle increased with increase in the unit weight from 8° to 55° in the consolidated undrained tests. Minor variations were found in the cohesion values. Relationships for strength and stiffness of MSW in terms of strength and stiffness ratios are developed and discussed. The stiffness ratio and the strength ratio of MSW were found to be 10 and 0.43

  12. Shear strength characteristics of mechanically biologically treated municipal solid waste (MBT-MSW) from Bangalore

    Energy Technology Data Exchange (ETDEWEB)

    Sivakumar Babu, G.L., E-mail: gls@civil.iisc.ernet.in [Department of Civil Engineering, Indian Institute of Science, Bangalore 560012 (India); Lakshmikanthan, P., E-mail: lakshmikanthancp@gmail.com [Centre for Sustainable Technologies (CST), Indian Institute of Science, Bangalore 560012 (India); Santhosh, L.G., E-mail: lgsanthu2006@gmail.com [Centre for Sustainable Technologies (CST), Indian Institute of Science, Bangalore 560012 (India)

    2015-05-15

    Highlights: • Shear strength properties of mechanically biologically treated municipal solid waste. • Effect of unit weight and particle size on the shear strength of waste. • Effect of particle size on the strength properties. • Stiffness ratio and the strength ratio of MSW. - Abstract: Strength and stiffness properties of municipal solid waste (MSW) are important in landfill design. This paper presents the results of comprehensive testing of shear strength properties of mechanically biologically treated municipal solid waste (MBT-MSW) in laboratory. Changes in shear strength of MSW as a function of unit weight and particle size were investigated by performing laboratory studies on the MSW collected from Mavallipura landfill site in Bangalore. Direct shear tests, small scale and large scale consolidated undrained and drained triaxial tests were conducted on reconstituted compost reject MSW samples. The triaxial test results showed that the MSW samples exhibited a strain-hardening behaviour and the strength of MSW increased with increase in unit weight. Consolidated drained tests showed that the mobilized shear strength of the MSW increased by 40% for a unit weight increase from 7.3 kN/m{sup 3} to 10.3 kN/m{sup 3} at 20% strain levels. The mobilized cohesion and friction angle ranged from 5 to 9 kPa and 8° to 33° corresponding to a strain level of 20%. The consolidated undrained tests exhibited reduced friction angle values compared to the consolidated drained tests. The friction angle increased with increase in the unit weight from 8° to 55° in the consolidated undrained tests. Minor variations were found in the cohesion values. Relationships for strength and stiffness of MSW in terms of strength and stiffness ratios are developed and discussed. The stiffness ratio and the strength ratio of MSW were found to be 10 and 0.43.

  13. Speed-strength abilities and morphological characteristics of basketball players aged 10 and 11

    Directory of Open Access Journals (Sweden)

    Đorđević Alen

    2016-01-01

    Full Text Available The aim of this study was to identify several morphological characteristics and speed-strength abilities in basketball players aged 10 and 11, and to determine possible differences between them, connected with their age. The research was conducted on a sample of 84 young basketball players aged 10 (N=46 and 11 (N=38. The following motor variables were measured: shoulder explosiveness (throwing the ball from basketball position, leg explosiveness (vertical jump, speed strength of the trunk (sit up exercises in 10 seconds, stamina in speed strength of the trunk (sit up exercises in 30 seconds, the speed of changing the direction of moving (agility T-test, acceleration (running for 5 and 20 meters. The following morphological variables were also measured: body height, body mass, percentage of body fat and percentage of muscle tissue. Eleven-year-olds achieved better results than the ten-year-olds in all categories. Statistically significant differences (p<0.01 between the two groups of subjects were found in body height, percentage of muscle tissue in the body, shoulder explosiveness, as well as in the speed of changing the direction of moving. Differences in body mass and ability for acceleration were found on the level of statistical significance (p<0.05.

  14. Dentin-Composite Bond Strength Measurement Using the Brazilian Disk Test

    Science.gov (United States)

    Carrera, Carola A.; Chen, Yung-Chung; Li, Yuping; Rudney, Joel; Aparicio, Conrado; Fok, Alex

    2016-01-01

    Objectives This study presents a variant of the Brazilian disk test (BDT) for assessing the bond strength between composite resins and dentin. Methods Dentin-composite disks (φ 5 mm × 2 mm) were prepared using either Z100 or Z250 (3M ESPE) in combination with one of three adhesives, Adper Easy Bond (EB), Adper Scotchbond Multi-Purpose (MP) and Adper Single Bond (SB), and tested under diametral compression. Acoustic emission (AE) and digital image correlation (DIC) were used to monitor debonding of the composite from the dentin ring. A finite element (FE) model was created to calculate the bond strengths using the failure loads. Fracture modes were examined by scanning electron microscopy (SEM). Results Most specimens fractured along the dentin-resin composite interface. DIC and AE confirmed interfacial debonding immediately before fracture of the dentin ring. Results showed that the mean bond strength with EB (14.9±1.9 MPa) was significantly higher than with MP (13.2±2.4 MPa) or SB (12.9±3.0 MPa) (p0.05). Z100 (14.5±2.3 MPa) showed higher bond strength than Z250 (12.7±2.5 MPa) (padhesive failure mode. EB failed mostly at the dentin-adhesive interface, whereas MP at the composite-adhesive interface; specimens with SB failed at the composite-adhesive interface and cohesively in the adhesive. Conclusions The BDT variant showed to be a suitable alternative for measuring the bond strength between dentin and composite, with zero premature failure, reduced variability in the measurements, and consistent failure at the dentin-composite interface. PMID:27395367

  15. A study on the safety of TBP(150A) with forming analysis and strength test

    International Nuclear Information System (INIS)

    Lee, Sung Ho; Kim, Hei Song

    2008-01-01

    For this study, the forming analyses and body strength tests of TBP were performed on the main pipe size 150A(KS D3507, KS D 3576 10S). The branched pipe sizes utilized were 25A, 32A, 40A, 50A, 65A, 80A, 100A and 125A. A general FEM program, ABAQUS, was used as the forming analyses method of TBP. Using the results, the strength of TBP was then tested in order to determine the safety of TBP when the working pressure was applied. The results indicate that TBP may be safely used in water-based fire protection pipe systems in terms of the strength

  16. Distribution of radiative strength with excitation energy: the E1 and M1 giant resonances

    International Nuclear Information System (INIS)

    Brown, G.E.; Speth, J.

    1979-01-01

    Calculations of the giant dipole resonance in the particle-hole model, employing empirical values for the unperturbed particle and hole energies, have been unsuccessful in pushing the dipole state to a sufficiently high energy. it is argued that unperturbed levels correspondign to an effective mass of m*/m approx. 0.6 to 0.7 should be employed. The couplings of particles and holes to vibrations are the crucial ingredients in these considerations. More generally, it is argued that the effective mass relevant to excitations near the Fermi surface is that corresponding to empirical single-particle levels, m*/m greater than or equal to 1.0. For particle-hole excitations above the Fermi surface, it is a decreasing function of excitation energy, reaching the above values 0.6 to 0.7 for E greater than or equal to 2 dirac constant/b omega, dirac constant/sub omega/ being the shell spacing. This has the consequence of spreading out the M1 strength. A new interpretation of experimental strengths is proposed

  17. Strength evaluation test of pressureless-sintered silicon nitride at room temperature

    Science.gov (United States)

    Matsusue, K.; Takahara, K.; Hashimoto, R.

    1984-01-01

    In order to study strength characteristics at room temperature and the strength evaluating method of ceramic materials, the following tests were conducted on pressureless sintered silicon nitride specimens: bending tests, the three tensile tests of rectangular plates, holed plates, and notched plates, and spin tests of centrally holed disks. The relationship between the mean strength of specimens and the effective volume of specimens are examined using Weibull's theory. The effect of surface grinding on the strength of specimens is discussed.

  18. 16 CFR 1203.16 - Dynamic strength of retention system test.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Dynamic strength of retention system test.... (2) The retention system strength test equipment shall consist of a dynamic impact apparatus that... stirrup. (2) Mark the pre-test position of the retention system, with the entire dynamic test apparatus...

  19. Maintenance and testing of anodized aluminum mirrors on the Whipple 10 m Whipple Telescope

    Science.gov (United States)

    Badran, H. M.; Weekes, T. C.

    2001-08-01

    Threshold energy sensitivity depends not only on the high reflectivity of the mirrors used in atmospheric Cherenkov telescopes but also on the maintenance of this reflectivity over months/years. The successful application of a mirror maintenance technique depends on the type of mirror coating and the contamination that must be removed. The uncovered mirrors in use on the 10-m Whipple gamma-ray telescope are anodized aluminum mirrors. A standard cleaning technique for such mirrors is not available. With the aim of extending the life of the aluminum coating exposed to the Mt ˙Hopkins environment, several cleaning procedures were tested on mirrors that had been exposed for three years. Evaluation of the most effective cleaners is presented. Preliminary results are also presented from a long-term experiment using newly coated mirrors at the proposed VERITAS site and at the current 10 m site. This experiment is designed to reveal the rates at which the reflectance degrades as a function of time, depth of anodization, storage direction, degree of covering, and maintenance procedures.

  20. Multistep triaxial strength tests: investigating strength parameters and pore pressure effects on Opalinus Clay

    International Nuclear Information System (INIS)

    Graesle, W.

    2010-01-01

    Document available in extended abstract form only. The impact of natural variability between rock samples from a single formation is a common problem for the characterisation of THM properties of rocks. Data variation arising from heterogeneity between samples often obscures details of material behaviour. Besides efforts to reduce this statistical noise by careful selection of samples, there are essentially two approaches to overcome this problem: - To generate very large data sets for better statistics. - To avoid the impact of natural variability by yielding an extensive data set from a single sample. The multistep strength test follows the latter approach to characterise the mechanical behaviour of Opalinus Clay from Mont Terri and the possible impact of pore pressure effects. The concept of the multistep strength test comprises three test sections, each focused on the investigation of one mechanical characteristic of Opalinus Clay. Any section is composed of a series of strain controlled load cycles at various levels of confining pressure. 1) The linear elastic limit, i.e. the onset of nonlinearity in the stress-strain-relationship σ dev (ε 1 ) during strain-controlled triaxial loading, is determined in section 1. It defines a lower limit for the onset of damage. Avoiding sample damage is essential during this test section to ensure that all measurements reflect the behaviour of undisturbed material. Therefore, a rather strict and well detectable criterion for the onset of nonlinearity is required to enable a timely termination of any load phase. 2) Section 2 is focused on shear strength. Any load cycle is stopped as soon as peak stress is detected. As progressive damage of the sample is unavoidable during this process, it must be expected that only very few measured peak stresses approximately represent properties of the undamaged material. 3) Test section 3 is a conventional test of residual strength. Tests are carried out on cylindrical samples (100 mm

  1. E1 and M1 strength functions at low energy

    Science.gov (United States)

    Schwengner, Ronald; Massarczyk, Ralph; Bemmerer, Daniel; Beyer, Roland; Junghans, Arnd R.; Kögler, Toni; Rusev, Gencho; Tonchev, Anton P.; Tornow, Werner; Wagner, Andreas

    2017-09-01

    We report photon-scattering experiments using bremsstrahlung at the γELBE facility of Helmholtz-Zentrum Dresden-Rossendorf and using quasi-monoenergetic, polarized γ beams at the HIγS facility of the Triangle Universities Nuclear Laboratory in Durham. To deduce the photoabsorption cross sections at high excitation energy and high level density, unresolved strength in the quasicontinuum of nuclear states has been taken into account. In the analysis of the spectra measured by using bremsstrahlung at γELBE, we perform simulations of statistical γ-ray cascades using the code γDEX to estimate intensities of inelastic transitions to low-lying excited states. Simulated average branching ratios are compared with model-independent branching ratios obtained from spectra measured by using monoenergetic γ beams at HIγS. E1 strength in the energy region of the pygmy dipole resonance is discussed in nuclei around mass 90 and in xenon isotopes. M1 strength in the region of the spin-flip resonance is also considered for xenon isotopes. The dipole strength function of 74Ge deduced from γELBE experiments is compared with the one obtained from experiments at the Oslo Cyclotron Laboratory. The low-energy upbend seen in the Oslo data is interpreted as M1 strength on the basis of shell-model calculations.

  2. E1 and M1 strength functions at low energy

    Directory of Open Access Journals (Sweden)

    Schwengner Ronald

    2017-01-01

    Full Text Available We report photon-scattering experiments using bremsstrahlung at the γELBE facility of Helmholtz-Zentrum Dresden-Rossendorf and using quasi-monoenergetic, polarized γ beams at the HIγS facility of the Triangle Universities Nuclear Laboratory in Durham. To deduce the photoabsorption cross sections at high excitation energy and high level density, unresolved strength in the quasicontinuum of nuclear states has been taken into account. In the analysis of the spectra measured by using bremsstrahlung at γELBE, we perform simulations of statistical γ-ray cascades using the code γDEX to estimate intensities of inelastic transitions to low-lying excited states. Simulated average branching ratios are compared with model-independent branching ratios obtained from spectra measured by using monoenergetic γ beams at HIγS. E1 strength in the energy region of the pygmy dipole resonance is discussed in nuclei around mass 90 and in xenon isotopes. M1 strength in the region of the spin-flip resonance is also considered for xenon isotopes. The dipole strength function of 74Ge deduced from γELBE experiments is compared with the one obtained from experiments at the Oslo Cyclotron Laboratory. The low-energy upbend seen in the Oslo data is interpreted as M1 strength on the basis of shell-model calculations.

  3. Strength of wood versus rate of testing - A theoretical approach

    DEFF Research Database (Denmark)

    Nielsen, Lauge Fuglsang

    2007-01-01

    Strength of wood is normally measured in ramp load experiments. Experience shows that strength increases with increasing rate of testing. This feature is considered theoretically in this paper. It is shown that the influence of testing rate is a phenomenon, which depends on the quality...... of the considered wood. Low quality wood shows lesser influence of testing rate. This observation agrees with the well-known statement made by Borg Madsen that weak wood subjected to a constant load, has a longer lifetime than strong wood. In general, the influence of testing rate on strength increases...

  4. Variação da pressão intraocular após teste submáximo de força no treinamento resistido Intraocular pressure variation after submaximal strength test in resistance training

    Directory of Open Access Journals (Sweden)

    Marcelo Conte

    2009-06-01

    Full Text Available OBJETIVO: Verificar a variação da pressão intraocular (PIO decorrente da aplicação do teste de predição para uma repetição máxima (1RM. MÉTODOS: Foram avaliados em estudo observacional 145 calouros (22,04 ± 4,17 anos; de ambos os sexos do curso de Educação Física da Escola Superior de Educação Física de Jundiaí (ESEFJ. Os critérios de exclusão foram: opacidade de meios, alteração de globo ocular ou ausência de globo ocular. Todos os participantes assinaram o Termo de Consentimento Livre e Esclarecido. A avaliação da PIO foi determinada por duas medidas consecutivas com o tonômetro de Perkins: i pré-teste: antes do teste de 1RM e ii pós-teste: logo após a realização do teste. O teste de 1RM consistiu em predizer o valor de uma repetição máxima através de repetições até a fadiga. Foram utilizados os seguintes exercícios resistidos: supino, pulley dorsal, desenvolvimento, rosca direta e leg press 45º. Como procedimento estatístico foi empregado o teste "t" de Student pareado. RESULTADOS: Ocorreu redução da PIO após a realização do teste de predição de 1RM: 13,48 ± 3,32 vs.10,20 ± 3,72 mmHg (pPURPOSE: To verify the intraocular pressure (IOP after sub-maximal strength test. METHODS: 145 Physical Education freshmen (22.04 ± 4.17 years old; female and male from Superior Physical Education School of Jundiaí (ESEFJ were evaluated in an observacional study. The exclusion criteria were: media opacity and eyeball absence or changes. All subjects agreed to take part in this research and signed up the Informed Consent. IOP was measured by Perkins tonometer: i pretest: just before the submaximal strength test performance and ii post-test: immediately after the strength test. The strength test consisted in the one-repetition-maximum-assessment through repetition until fatigue. Resistance training exercises such as bench press, pulley dorsal high, shoulder press, arm curl and leg press 45º were performed

  5. Evaluation of microtensile and tensile bond strength tests ...

    African Journals Online (AJOL)

    2015-11-03

    Nov 3, 2015 ... Bond strength tests and Er,Cr:YSGG laser frequency. 586 ... power, 90% air pressure, 75% water pressure, 45 s irradiation ..... geometry on the measurement of the tensile bond strength to dentin. J Dent ... Bur‑cut enamel and.

  6. The strength of the M2 transition from the 7-/2 hole state in 43K

    International Nuclear Information System (INIS)

    Poletti, A.R.; Southon, J.R.

    1977-01-01

    The mean life of the 738 keV level of 43 K has been measured by direct electronic timing as tausub(m) = 265 +- 15 ns. The reaction 40 Ar(α,pγ) 43 K at 10.4 MeV was used to excite the level. A comparison is made with another recent measurement while the deduced M2 strength is compared with those in other potassium isotopes. (author)

  7. Improvement of Ice Hockey Players' On-Ice Sprint With Combined Plyometric and Strength Training.

    Science.gov (United States)

    Dæhlin, Torstein E; Haugen, Ole C; Haugerud, Simen; Hollan, Ivana; Raastad, Truls; Rønnestad, Bent R

    2017-08-01

    Combined plyometric and strength training has previously been suggested as a strategy to improve skating performance in ice hockey players. However, the effects of combined plyometric and strength training have not previously been compared with the effects of strength training only. To compare the effects of combined plyometric and strength training on ice hockey players' skating sprint performance with those of strength training only. Eighteen participants were randomly assigned to 2 groups that completed 5 strength-training sessions/wk for 8 wk. One group included plyometric exercises at the start of 3 sessions/wk (PLY+ST), and the other group included core exercises in the same sessions (ST). Tests of 10- and 35-m skating sprints, horizontal jumping, 1-repetition-maximum (1 RM) squat, skating multistage aerobic test (SMAT), maximal oxygen consumption, repeated cycle sprints, and body composition were performed before and after the intervention. The participants increased their 1RM squat, lean mass, and body mass (P plyometric and strength training for 8 wk was superior to strength training alone at improving 10-m on-ice sprint performance in high-level ice hockey players.

  8. Laboratory test for ice adhesion strength using commercial instrumentation.

    Science.gov (United States)

    Wang, Chenyu; Zhang, Wei; Siva, Adarsh; Tiea, Daniel; Wynne, Kenneth J

    2014-01-21

    A laboratory test method for evaluating ice adhesion has been developed employing a commercially available instrument normally used for dynamic mechanical analysis (TA RSA-III). This is the first laboratory ice adhesion test that does not require a custom-built apparatus. The upper grip range of ∼10 mm is an enabling feature that is essential for the test. The method involves removal of an ice cylinder from a polymer coating with a probe and the determination of peak removal force (Ps). To validate the test method, the strength of ice adhesion was determined for a prototypical glassy polymer, poly(methyl methacrylate). The distance of the probe from the PMMA surface has been identified as a critical variable for Ps. The new test provides a readily available platform for investigating fundamental surface characteristics affecting ice adhesion. In addition to the ice release test, PMMA coatings were characterized using DSC, DCA, and TM-AFM.

  9. The responsiveness of sensibility and strength tests in patients undergoing carpal tunnel decompression

    Directory of Open Access Journals (Sweden)

    Miller Leanne

    2011-10-01

    Full Text Available Abstract Background Several clinical measures of sensory and motor function are used alongside patient-rated questionnaires to assess outcomes of carpal tunnel decompression. However there is a lack of evidence regarding which clinical tests are most responsive to clinically important change over time. Methods In a prospective cohort study 63 patients undergoing carpal tunnel decompression were assessed using standardised clinician-derived and patient reported outcomes before surgery, at 4 and 8 months follow up. Clinical sensory assessments included: touch threshold with monofilaments (WEST, shape-texture identification (STI™ test, static two-point discrimination (Mackinnon-Dellon Disk-Criminator and the locognosia test. Motor assessments included: grip and tripod pinch strength using a digital grip analyser (MIE, manual muscle testing of abductor pollicis brevis and opponens pollicis using the Rotterdam Intrinsic Handheld Myometer (RIHM. The Boston Carpal Tunnel Questionnaire (BCTQ was used as a patient rated outcome measure. Results Relative responsiveness at 4 months was highest for the BCTQ symptom severity scale with moderate to large effects sizes (ES = -1.43 followed by the BCTQ function scale (ES = -0.71. The WEST and STI™ were the most responsive sensory tests at 4 months showing moderate effect sizes (WEST ES = 0.55, STI ES = 0.52. Grip and pinch strength had a relatively higher responsiveness compared to thenar muscle strength but effect sizes for all motor tests were very small (ES ≤0.10 or negative indicating a decline compared to baseline in some patients. Conclusions For clinical assessment of sensibility touch threshold assessed by monofilaments (WEST and tactile gnosis measured with the STI™ test are the most responsive tests and are recommended for future studies. The use of handheld myometry (RIHM for manual muscle testing, despite more specifically targeting thenar muscles, was less responsive than grip or tripod

  10. Validity of the German Version of the Continuous-Scale Physical Functional Performance 10 Test

    Directory of Open Access Journals (Sweden)

    Irene Härdi

    2017-01-01

    Full Text Available Background. The Continuous-Scale Physical Functional Performance 10 Test (CS-PFP 10 quantitatively assesses physical functional performance in older adults who have a broad range of physical functional ability. This study assessed the validity and reliability of the CS-PFP 10 German version. Methods. Forward-translations and backtranslations as well as cultural adaptions of the test were conducted. Participants were German-speaking Swiss community-dwelling adults aged 64 and older. Concurrent validity was assessed using Pearson correlation coefficients between CS-PFP 10 and gait velocity, Timed Up and Go Test, hand grip strength, SF-36 physical function domain, and Freiburger Physical Activity Questionnaire. Internal consistency was calculated by Cronbach’s alpha. Results. Backtranslation and cultural adaptions were accepted by the CS-PFP 10 developer. CS-PFP 10 total score and subscores (upper body strength, upper body flexibility, lower body strength, balance and coordination, and endurance correlated significantly with all measures of physical function tested. Internal consistency was high (Cronbach’s alpha 0.95–0.98. Conclusion. The CS-PFP 10 German version is valid and reliable for measuring physical functional performance in German-speaking Swiss community-dwelling older adults. Quantifying physical function is essential for clinical practice and research and provides meaningful insight into physical functional performance of older adults. This trial is registered with ClinicalTrials.gov NCT01539200.

  11. Low-Cycle Fatigue Behavior of 10CrNi3MoV High Strength Steel and Its Undermatched Welds.

    Science.gov (United States)

    Song, Wei; Liu, Xuesong; Berto, Filippo; Razavi, S M J

    2018-04-24

    The use of high strength steel allows the design of lighter, more slender and simpler structures due to high strength and favorable ductility. Nevertheless, the increase of yield strength does not guarantee the corresponding improvement of fatigue resistance, which becomes a major concern for engineering structure design, especially for the welded joints. The paper presents a comparison of the low cycle fatigue behaviors between 10CrNi3MoV high strength steel and its undermatched weldments. Uniaxial tension tests, Push-pull, strain-controlled fatigue tests were conducted on base metal and weldments in the strain range of 0.2⁻1.2%. The monotonic and cyclic stress-strain curves, stress-life, strain-life and energy-life in terms of these materials were analyzed for fatigue assessment of materials discrepancy. The stress-life results of base metal and undermatched weld metal exhibit cyclic softening behaviors. Furthermore, the shapes of 10CrNi3MoV steel hysteresis loops show a satisfactory Masing-type behavior, while the weld metal shows a non-Masing type behavior. Strain, plastic and total strain energy density amplitudes against the number of reversals to failure results demonstrate that the undermatched weld metal presents a higher resistance to fatigue crack initiation than 10CrNi3MoV high strength steel. Finally, fatigue fracture surfaces of specimens were compared by scanning electron microscopy to identify the differences of crack initiation and the propagation between them.

  12. Low-Cycle Fatigue Behavior of 10CrNi3MoV High Strength Steel and Its Undermatched Welds

    Directory of Open Access Journals (Sweden)

    Wei Song

    2018-04-01

    Full Text Available The use of high strength steel allows the design of lighter, more slender and simpler structures due to high strength and favorable ductility. Nevertheless, the increase of yield strength does not guarantee the corresponding improvement of fatigue resistance, which becomes a major concern for engineering structure design, especially for the welded joints. The paper presents a comparison of the low cycle fatigue behaviors between 10CrNi3MoV high strength steel and its undermatched weldments. Uniaxial tension tests, Push-pull, strain-controlled fatigue tests were conducted on base metal and weldments in the strain range of 0.2–1.2%. The monotonic and cyclic stress-strain curves, stress-life, strain-life and energy-life in terms of these materials were analyzed for fatigue assessment of materials discrepancy. The stress-life results of base metal and undermatched weld metal exhibit cyclic softening behaviors. Furthermore, the shapes of 10CrNi3MoV steel hysteresis loops show a satisfactory Masing-type behavior, while the weld metal shows a non-Masing type behavior. Strain, plastic and total strain energy density amplitudes against the number of reversals to failure results demonstrate that the undermatched weld metal presents a higher resistance to fatigue crack initiation than 10CrNi3MoV high strength steel. Finally, fatigue fracture surfaces of specimens were compared by scanning electron microscopy to identify the differences of crack initiation and the propagation between them.

  13. Strength Tests on Hulls and Floats

    Science.gov (United States)

    Matthaes, K

    1942-01-01

    The present report deals with strength tests on hulls and floats intended in part for the collection of construction data for the design of these components and in part for the stress analysis of the finished hulls and floats.

  14. [Bond strengths of customized titanium brackets manufactured by selective laser melting].

    Science.gov (United States)

    Zou, Dao-xing; Wang, Ze-min; Guo, Hong-ming; Li, Song; Bai, Yu-xing

    2013-07-01

    To investigate the bond strengths of customized titanium bracket manufactured by selective laser melting. Eighty human premolars which had been extracted for orthodontic purpose were collected and divided randomly (by random table) into two groups (customized bracket group and 3M bracket group, 40 molars in each group). The 35% phosphoric acid was used for etching and the brackets were bonded with 3M Unitek bonding adhesive. All bonded specimens were placed in saline for 24 hours at room temperature and were tested on DWD3050 electronic testing machine to determine the shear bond strength and tensile bond strength. After debonding, the adhesive remnant indexes (ARI) were recorded. The shear bond strengths of customized brackets was 6.80 (6.20, 8.32) MPa, which was significantly lower than that of the 3M brackets [10.46 (9.72, 11.48) MPa] (Z = -3.463, P < 0.05). And the tensile bond strengths of customized brackets was (6.93 ± 1.21) MPa, which was significantly higher than that of the 3M brackets [(5.88 ± 1.23) MPa] (t = 2.81, P < 0.05). No significant difference was found in the ARI between two different kinds of the brackets. The shear bond strength and tensile bond strength of both kinds of brackets were enough for clinic application.

  15. Reliability of Maximal Strength Testing in Novice Weightlifters

    Science.gov (United States)

    Loehr, James A.; Lee, Stuart M. C.; Feiveson, Alan H.; Ploutz-Snyder, Lori L.

    2009-01-01

    The one repetition maximum (1RM) is a criterion measure of muscle strength. However, the reliability of 1RM testing in novice subjects has received little attention. Understanding this information is crucial to accurately interpret changes in muscle strength. To evaluate the test-retest reliability of a squat (SQ), heel raise (HR), and deadlift (DL) 1RM in novice subjects. Twenty healthy males (31 plus or minus 5 y, 179.1 plus or minus 6.1 cm, 81.4 plus or minus 10.6 kg) with no weight training experience in the previous six months participated in four 1RM testing sessions, with each session separated by 5-7 days. SQ and HR 1RM were conducted using a smith machine; DL 1RM was assessed using free weights. Session 1 was considered a familiarization and was not included in the statistical analyses. Repeated measures analysis of variance with Tukey fs post-hoc tests were used to detect between-session differences in 1RM (p.0.05). Test-retest reliability was evaluated by intraclass correlation coefficients (ICC). During Session 2, the SQ and DL 1RM (SQ: 90.2 }4.3, DL: 75.9 }3.3 kg) were less than Session 3 (SQ: 95.3 }4.1, DL: 81.5 plus or minus 3.5 kg) and Session 4 (SQ: 96.6 }4.0, DL: 82.4 }3.9 kg), but there were no differences between Session 3 and Session 4. HR 1RM measured during Session 2 (150.1 }3.7 kg) and Session 3 (152.5 }3.9 kg) were not different from one another, but both were less than Session 4 (157.5 }3.8 kg). The reliability (ICC) of 1RM measures for Sessions 2-4 were 0.88, 0.83, and 0.87, for SQ, HR, and DL, respectively. When considering only Sessions 3 and 4, the reliability was 0.93, 0.91, and 0.86 for SQ, HR, and DL, respectively. One familiarization session and 2 test sessions (for SQ and DL) were required to obtain excellent reliability (ICC greater than or equal to 0.90) in 1RM values with novice subjects. We were unable to attain this level of reliability following 3 HR testing sessions therefore additional sessions may be required to obtain an

  16. Repair bond strength of nanohybrid composite resins with a universal adhesive.

    Science.gov (United States)

    Altinci, Pinar; Mutluay, Murat; Tezvergil-Mutluay, Arzu

    2018-01-01

    Objective: To investigate the repair bond strength of fresh and aged nanohybrid and hybrid composite resins using a universal adhesive (UA). Materials and methods: Fresh and aged substrates were prepared using two nanohybrid (Venus Pearl, Heraus Kulzer; Filtek Supreme XTE, 3 M ESPE) and one hybrid (Z100, 3 M ESPE) composite resin, and randomly assigned to different surface treatments: (1) no treatment (control), (2) surface roughening with 320-grit (SR), (3) SR + UA (iBOND, Heraus Kulzer), (4) SR + Silane (Signum, Ceramic Bond I, Heraeus Kulzer) + UA, (5) SR + Sandblasting (CoJet, 3 M ESPE) + Silane + UA. After surface treatment, fresh composite resin was added to the substrates at 2 mm layer increments to a height of 5 mm, and light cured. Restored specimens were water-stored for 24 h and sectioned to obtain 1.0 × 1.0 mm beams ( n  = 12), and were either water-stored for 24 h at 37 °C, or water-stored for 24 h, and then thermocycled for 6000 cycles before microtensile bond strength (µTBS) testing. Data were analyzed with ANOVA and Tukey's HSD tests ( p  = .05). Results: Combined treatment of SR, sandblasting, silane and UA provided repair bond strength values comparable to the cohesive strength of each tested resin material ( p  composite resins upto 65% ( p  composite repair. Sandblasting and silane application slightly increases the repair strength for all substrate types.

  17. Six-minute walk test and respiratory muscle strength in patients with uncontrolled severe asthma: a pilot study.

    Science.gov (United States)

    Pereira, Luiz Fernando Ferreira; Mancuzo, Eliane Viana; Rezende, Camila Farnese; Côrrea, Ricardo de Amorim

    2015-01-01

    To evaluate respiratory muscle strength and six-minute walk test (6MWT) variables in patients with uncontrolled severe asthma (UCSA). This was a cross-sectional study involving UCSA patients followed at a university hospital. The patients underwent 6MWT, spirometry, and measurements of respiratory muscle strength, as well as completing the Asthma Control Test (ACT). The Mann-Whitney test was used in order to analyze 6MWT variables, whereas the Kruskal-Wallis test was used to determine whether there was an association between the use of oral corticosteroids and respiratory muscle strength. We included 25 patients. Mean FEV1 was 58.8 ± 21.8% of predicted, and mean ACT score was 14.0 ± 3.9 points. No significant difference was found between the median six-minute walk distance recorded for the UCSA patients and that predicted for healthy Brazilians (512 m and 534 m, respectively; p = 0.14). During the 6MWT, there was no significant drop in SpO2. Mean MIP and MEP were normal (72.9 ± 15.2% and 67.6 ± 22.2%, respectively). Comparing the patients treated with at least four courses of oral corticosteroids per year and those treated with three or fewer, we found no significant differences in MIP (p = 0.15) or MEP (p = 0.45). Our findings suggest that UCSA patients are similar to normal subjects in terms of 6MWT variables and respiratory muscle strength. The use of oral corticosteroids has no apparent impact on respiratory muscle strength.

  18. Long-term strength and allowable stresses of grade 10Kh9MFB and X10CrMoVNb9-1 (T91/P91) chromium heat-resistant steels

    Science.gov (United States)

    Skorobogatykh, V. N.; Danyushevskiy, I. A.; Schenkova, I. A.; Prudnikov, D. A.

    2015-04-01

    Currently, grade X10CrMoVNb9-1 (T91, P91) and 10Kh9MFB (10Kh9MFB-Sh) chromium steels are widely applied in equipment manufacturing for thermal power plants in Russia and abroad. Compilation and comparison of tensile, impact, and long-term strength tests results accumulated for many years of investigations of foreign grade X10CrMoVNb9-1, T91, P91, and domestic grade 10Kh9MFB (10Kh9MFB-Sh) steels is carried out. The property identity of metals investigated is established. High strength and plastic properties of steels, from which pipes and other products are made, for operation under creep conditions are confirmed. Design characteristics of long-term strength on the basis of tests with more than one million of hour-samples are determined ( and at temperatures of 500-650°C). The table of recommended allowable stresses for grade 10Kh9MFB, 10Kh9MFB-SH, X10CrMoVNb9-1, T91, and P91 steels is developed. The long-time properties of pipe welded joints of grade 10Kh9MFB+10Kh9MFB, 10Kh9MFB-Sh+10Kh9MFB-Sh, X10CrMoVNb9-1+X10CrMoVNb9-1, P91+P91, T91+T91, 10Kh9MFB (10Kh9MFB-Sh)+X10CrMoVNb9-1(T/P91) steels is researched. The welded joint reduction factor is experimentally determined.

  19. A Study on the Small Punch Test for Fracture Strength Evaluation of CANDU Pressure Tube Embrittled by Hydrogen

    International Nuclear Information System (INIS)

    Nho, Seung Hwan; Ong, Jang Woo; Yu, Hyo Sun; Chung, Se Hi

    1996-01-01

    The purpose of this study is to investigate the usefulness of small punch(SP) test using miniaturized specimens as a method for fracture strength evaluation of CANDU pressure tube embrittled by hydrogen. According to the test results, the fracture strength evaluation as a function of hydrogen concentration at -196 .deg. C was much better than that at room temperature, as the difference of SP fracture energy(Esp) with hydrogen concentration was more significant at -196 .deg. C than at room temperature for the hydrogen concentration up to 300ppm-H. It was also observed that the peak of average AE energy, the cumulative average AE energy and the cumulative average AE energy per equivalent fracture, strain increased with the increase of hydrogen concentration. From the results of load-displacement behaviors, Esp behaviors, macro- and micro-SEM fractographs and AE test it has been concluded that the SP test method using miniaturized specimen(10mmx10mmx0.5mm) will be a useful test method to evaluate the fracture strength for CANDU pressure tube embrittled by hydrogen

  20. Nondestructive test for estimating strength of concrete in structure

    International Nuclear Information System (INIS)

    Nozaki, Yoshitsugu; Soshiroda, Tomozo

    1997-01-01

    Evaluation of the quality of concrete in structures, especially strength estimation is said to be one of the most important problem and needed to establish test method especial tv for non-destructive method in situ. The paper describes the nondestructive test to estimate strength of concrete. From experimental study using full scale model wall, strength estimating equations are proposed by ultra-sonic pulse velocity, rebound hardness of Schmidt hammer and combined with two methods. From statistical study of the results of experiments, errors of estimated strength by the proposed equations are suggested. The validity of the equations are verified by investigation for existing reinforced concrete buildings aged 20 - 50 years. And it was found from the statistical study that the strength estimating equations need to be corrected in applying to tons aged concrete, and correction factor to those squat ions were suggested. Furthermore the corrected proposed equations were verified by applying to buildings investigated the other case.

  1. Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke.

    Science.gov (United States)

    Mentiplay, Benjamin F; Tan, Dawn; Williams, Gavin; Adair, Brooke; Pua, Yong-Hao; Bower, Kelly J; Clark, Ross A

    2018-04-27

    Isometric rate of torque development examines how quickly force can be exerted and may resemble everyday task demands more closely than isometric strength. Rate of torque development may provide further insight into the relationship between muscle function and gait following stroke. Aims of this study were to examine the test-retest reliability of hand-held dynamometry to measure isometric rate of torque development following stroke, to examine associations between strength and rate of torque development, and to compare the relationships of strength and rate of torque development to gait velocity. Sixty-three post-stroke adults participated (60 years, 34 male). Gait velocity was assessed using the fast-paced 10m walk test. Isometric strength and rate of torque development of seven lower-limb muscle groups were assessed with hand-held dynamometry. Intraclass correlation coefficients were calculated for reliability and Spearman's rho correlations were calculated for associations. Regression analyses using partial F-tests were used to compare strength and rate of torque development in their relationship with gait velocity. Good to excellent reliability was shown for strength and rate of torque development (0.82-0.97). Strong associations were found between strength and rate of torque development (0.71-0.94). Despite high correlations between strength and rate of torque development, rate of torque development failed to provide significant value to regression models that already contained strength. Assessment of isometric rate of torque development with hand-held dynamometry is reliable following stroke, however isometric strength demonstrated greater relationships with gait velocity. Further research should examine the relationship between dynamic measures of muscle strength/torque and gait after stroke. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Assessment of the tests results of the two CERN-INFN 10 m long superconducting dipole prototypes for the LHC

    International Nuclear Information System (INIS)

    Bona, M.; Perin, R.; Acerbi, E.; Rossi, L.

    1996-01-01

    In the first phase of the R and D program for LHC dipoles, seven 10-m-long, 50-mm-aperture prototypes have been manufactured by European Industries. The first two prototypes, fabricated under a CERN-INFN Collaboration, were successfully tested in 1994. This paper provides a first assessment of the main test results of these two magnets, in particular for what concerns kinematics and evolution of the stress distribution in the magnet during cooldown, energization and warmup. The influence of some adopted technological solutions is also discussed. Based on test results, some design corrections are proposed for adoption in the design of the future 15-m-long LHC dipole prototype

  3. Evaluation of acceptance strength tests for concrete pavements.

    Science.gov (United States)

    2005-06-30

    The North Carolina Department of Transportation has used traditionally flexural strength tests for acceptance : testing of Portland cement concrete pavements. This report summarizes a research project implemented to : investigate the feasibility of u...

  4. Long-term outcome of muscle strength in ulnar and median nerve injury: Comparing manual muscle strength testing, grip and pinch strength dynamometers and a new intrinsic muscle strength dynamometer

    NARCIS (Netherlands)

    A.R. Schreuders (Ton); M.E. Roebroeck (Marij); J.B. Jaquet (Jean); S.E.R. Hovius (Steven); H.J. Stam (Henk)

    2004-01-01

    textabstractObjective: To compare the outcome of muscle strength with manual muscle strength testing grip and pinch strength measurements and a dynamometer which allows for measurements of the intrinsic muscles of the hand in isolation (the Rotterdam Intrinsic Hand Myometer, RIHM). Methods:

  5. Reliability, Validity, and Sensitivity of a Novel Smartphone-Based Eccentric Hamstring Strength Test in Professional Football Players.

    Science.gov (United States)

    Lee, Justin W Y; Cai, Ming-Jing; Yung, Patrick S H; Chan, Kai-Ming

    2018-05-01

    To evaluate the test-retest reliability, sensitivity, and concurrent validity of a smartphone-based method for assessing eccentric hamstring strength among male professional football players. A total of 25 healthy male professional football players performed the Chinese University of Hong Kong (CUHK) Nordic break-point test, hamstring fatigue protocol, and isokinetic hamstring strength test. The CUHK Nordic break-point test is based on a Nordic hamstring exercise. The Nordic break-point angle was defined as the maximum point where the participant could no longer support the weight of his body against gravity. The criterion for the sensitivity test was the presprinting and postsprinting difference of the Nordic break-point angle with a hamstring fatigue protocol. The hamstring fatigue protocol consists of 12 repetitions of the 30-m sprint with 30-s recoveries between sprints. Hamstring peak torque of the isokinetic hamstring strength test was used as the criterion for validity. A high test-retest reliability (intraclass correlation coefficient = .94; 95% confidence interval, .82-.98) was found in the Nordic break-point angle measurements. The Nordic break-point angle significantly correlated with isokinetic hamstring peak torques at eccentric action of 30°/s (r = .88, r 2  = .77, P hamstring strength measures among male professional football players.

  6. Enhanced Strength and Sprint Levels, and Changes in Blood Parameters during a Complete Athletics Season in 800 m High-Level Athletes

    Directory of Open Access Journals (Sweden)

    Beatriz Bachero-Mena

    2017-08-01

    Full Text Available The purpose of this study was to analyze changes in sprint, strength, hematological, and hormonal parameters in high-level 800 m athletes during a complete athletics season. Thirteen male athletes of national and international level in 800 m (personal best ranging from 1:43 to 1:58 min:ss participated in this study. A total of 5 tests were conducted during a complete athletics season. Athletes performed sprint tests (20 and 200 m, countermovement jump (CMJ, jump squat (JS, and full squat (SQ tests. Blood samples (red and white blood profile and hormones were collected in test 1 (T1, test 3 (T3, and test 5 (T5. A general increase in the performance of the strength and sprint parameters analyzed (CMJ, JS, SQ, 20 m, and 200 m during the season was observed, with a significant time effect in CMJ (P < 0.01, SQ (P < 0.01, and 200 m (P < 0.05. This improvement was accompanied by a significant enhancement of the 800 m performance from T3 to T5 (P < 0.01. Significant changes in some hematological variables: hematocrit (Hct (P < 0.01, mean corpuscular volume (MCV (P < 0.001, mean corpuscular hemoglobin content (MCHC (P < 0.001, white blood cells count (WBC (P < 0.05, neutrophils (P < 0.05, monocytes (P < 0.05, and mean platelet volume (MPV (P < 0.05 were observed throughout the season. The hormonal response and creatin kinase (CK did not show significant variations during the season, except for insulin-like growth factor I (IGF-1 (P < 0.05. In conclusion, our results suggest the importance of strength levels in middle-distance athletes. On the other hand, variations in some hematological parameters and a depression of the immune system occurred during the season. Therefore, monitoring of the mechanical, hematological and hormonal response in athletes may help coaches and athletes to optimize the regulation of training contents and may be useful to diagnose states of overreaching or overtraining in athletes throughout the season.

  7. E2 and M1 transition strengths in heavy deformed nuclei revisited

    International Nuclear Information System (INIS)

    Draayer, J.P.; Popa, G.; Hirsch, J.G.; Vargas, C.E.

    2003-01-01

    An update on the status of pseudo-SU(3) shell-model calculations in strongly deformed nuclei in the rare earth region is presented. Representative results for energy levels as well as E2 (quadrupole) and M1 (scissors) transitions strengths in 162 Dy (even-even) and 163 Dy (odd-mass) are given. The calculations use realistic single-particle energies and quadrupole-quadrupole and pairing interaction strengths fixed from systematics. The strengths of rotor-like terms included in the Hamiltonian- all small relative to the other terms in the interaction were adjusted to give an overall best fit to the energy spectra. The results present a paradox: for even-even nuclei (integer angular momentum) non-zero pseudo-spin configurations seems to be unimportant while for the odd-mass systems (half-integer angular momentum) pseudo-spin mixing is essential as spin-flip couplings appear to dominate the M1 transition strengths. (Author)

  8. First evidence for spin-flip M1 strength in 40Ar

    International Nuclear Information System (INIS)

    Li, T.C.; Rainovski, G.; Pietralla, N.; Ahn, T.; Costin, A.; Tonchev, A.P.; Ahmed, M.W.; Blackston, M.A.; Parpottas, Y.; Perdue, B.A.; Tornow, W.; Weller, H.R.; Angell, C.; Keeter, K.J.; Li, J.; Mikhailov, S.; Wu, Y.K.; Lisetskiy, A.

    2006-01-01

    The 40 Ar(γ→,γ ' ) photon scattering reaction was used to search for spin-flip M1 strength in 40 Ar. The nearly monochromatic, linearly polarized photon beam of HIγS, in an energy region from 7.7 to 11 MeV, was employed in this study. 28 dipole excitations were observed. The azimuthal intensity asymmetry indicated that all of these states were E1 except for the state at E x =9.757 MeV. Shell-model calculations were used to interpret this state as one fragment of the spin-flip M1 strength in 40 Ar

  9. Effects of different strength training frequencies on maximum strength, body composition and functional capacity in healthy older individuals.

    Science.gov (United States)

    Turpela, Mari; Häkkinen, Keijo; Haff, Guy Gregory; Walker, Simon

    2017-11-01

    There is controversy in the literature regarding the dose-response relationship of strength training in healthy older participants. The present study determined training frequency effects on maximum strength, muscle mass and functional capacity over 6months following an initial 3-month preparatory strength training period. One-hundred and six 64-75year old volunteers were randomly assigned to one of four groups; performing strength training one (EX1), two (EX2), or three (EX3) times per week and a non-training control (CON) group. Whole-body strength training was performed using 2-5 sets and 4-12 repetitions per exercise and 7-9 exercises per session. Before and after the intervention, maximum dynamic leg press (1-RM) and isometric knee extensor and plantarflexor strength, body composition and quadriceps cross-sectional area, as well as functional capacity (maximum 7.5m forward and backward walking speed, timed-up-and-go test, loaded 10-stair climb test) were measured. All experimental groups increased leg press 1-RM more than CON (EX1: 3±8%, EX2: 6±6%, EX3: 10±8%, CON: -3±6%, Ptraining frequency would induce greater benefit to maximum walking speed (i.e. functional capacity) despite a clear dose-response in dynamic 1-RM strength, at least when predominantly using machine weight-training. It appears that beneficial functional capacity improvements can be achieved through low frequency training (i.e. 1-2 times per week) in previously untrained healthy older participants. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Relationship between the modified star excursion balance test and the 4x10 m shuttle run test in children

    Directory of Open Access Journals (Sweden)

    Joaquín Calatayud

    2017-01-01

    Full Text Available Resumen La agilidad y el equilibrio dinámico son habilidades cruciales en la actividad física prepuberal y la participación deportiva, por lo tanto es necesaria la identificación de pruebas eficientes para su evaluación. Evaluar la correlación entre la agilidad y el equilibrio dinámico en niños escolares de primaria. Veintisiete niños y veinte niñas de 10 años participaron voluntariamente en el estudio. El Star Excursion Balance Test (SEBT modificado y el 4x10 m Shuttle Run Test se utilizaron respectivamente para evaluar el equilibrio dinámico y agilidad. Las puntuaciones compuestas del equilibrio dinámico con apoyo diestro mostraron solo entre los niños una moderada correlación significativa (r = -0.51, p < 0.05 con la prueba de agilidad. Sin embargo, entre las niñas se mostró una correlación significativa (r = -0.45, p < 0.05 durante la distancia de alcance posterolateral obtenida en el SEBT. La realización del test completo o de las distancias alcanzadas a nivel posteromedial y posterolateral del SEBT se asocia moderadamente con la agilidad entre los niños, mientras que la distancia posterolateral se asocia con la agilidad entre las niñas.

  11. Yield strengths of tungsten-base composites determined from bend tests

    International Nuclear Information System (INIS)

    Zukas, E.G.; Eash, D.T.

    1976-08-01

    The variation in yield strength with either strain rate or temperature was determined for a number of tungsten-base composites by use of the simple three-point bend test. The yield strengths were comparable with those obtained in standard tensile tests. Additional studies on 1019 steel, either in the as-rolled or annealed condition, gave results in agreement with handbook values, as did two aluminum alloys. These results demonstrate that the bend test deserves wider acceptance in materials testing programs

  12. Strength and Pain Threshold Handheld Dynamometry Test Reliability in Patellofemoral Pain.

    Science.gov (United States)

    van der Heijden, R A; Vollebregt, T; Bierma-Zeinstra, S M A; van Middelkoop, M

    2015-12-01

    Patellofemoral pain syndrome (PFPS), characterized by peri- and retropatellar pain, is a common disorder in young, active people. The etiology is unclear; however, quadriceps strength seems to be a contributing factor, and sensitization might play a role. The study purpose is determining the inter-rater reliability of handheld dynamometry to test both quadriceps strength and pressure pain threshold (PPT), a measure for sensitization, in patients with PFPS. This cross-sectional case-control study comprises 3 quadriceps strength and one PPT measurements performed by 2 independent investigators in 22 PFPS patients and 16 matched controls. Inter-rater reliability was analyzed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Inter-rater reliability of quadriceps strength testing was fair to good in PFPS patients (ICC=0.72) and controls (ICC=0.63). Bland-Altman plots showed an increased difference between assessors when average quadriceps strength values exceeded 250 N. Inter-rater reliability of PPT was excellent in patients (ICC=0.79) and fair to good in controls (ICC=0.52). Handheld dynamometry seems to be a reliable method to test both quadriceps strength and PPT in PFPS patients. Inter-rater reliability was higher in PFPS patients compared to control subjects. With regard to quadriceps testing, a higher variance between assessors occurs when quadriceps strength increases. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Fracture toughness versus micro-tensile bond strength testing of adhesive-dentin interfaces.

    Science.gov (United States)

    De Munck, Jan; Luehrs, Anne-Katrin; Poitevin, André; Van Ende, Annelies; Van Meerbeek, Bart

    2013-06-01

    To assess interfacial fracture toughness of different adhesive approaches and compare to a standard micro-tensile bond-strength (μTBS) test. Chevron-notched beam fracture toughness (CNB) was measured following a modified ISO 24370 standard. Composite bars with dimensions of 3.0×4.0×25 mm were prepared, with the adhesive-dentin interface in the middle. At the adhesive-dentin interface, a chevron notch was prepared using a 0.15 mm thin diamond blade mounted in a water-cooled diamond saw. Each specimen was loaded until failure in a 4-point bend test setup and the fracture toughness was calculated according to the ISO specifications. Similarly, adhesive-dentin micro-specimens (1.0×1.0×8-10 mm) were stressed in tensile until failure to determine the μTBS. A positive correlation (r(2)=0.64) was observed between CNB and μTBS, which however was only nearly statistically significant, mainly due to the dissimilar outcome of Scotchbond Universal (3M ESPE). While few μTBS specimens failed at the adhesive-dentin interface, almost all CNB specimens failed interfacially at the notch tip. Weibull moduli for interfacial fracture toughness were much higher than for μTBS (3.8-11.5 versus 2.7-4.8, respectively), especially relevant with regard to early failures. Although the ranking of the adhesives on their bonding effectiveness tested using CNB and μTBS corresponded well, the outcome of CNB appeared more reliable and less variable. Fracture toughness measurement is however more laborious and requires specific equipment. The μTBS nevertheless appeared to remain a valid method to assess bonding effectiveness in a versatile way. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Generating an Automated Test Suite by Variable Strength Combinatorial Testing for Web Services

    Directory of Open Access Journals (Sweden)

    Yin Li

    2016-09-01

    Full Text Available Testing Web Services has become the spotlight of software engineering as an important means to assure the quality of Web application. Due to lacking of graphic interface and source code, Web services need an automated testing method, which is an important part in efficiently designing and generating test suite. However, the existing testing methods may lead to the redundancy of test suite and the decrease of fault-detecting ability since it cannot handle scenarios where the strengths of the different interactions are not uniform. With the purpose of solving this problem, firstly the formal tree model based on WSDL is constructed and the actual interaction relationship of each node is made sufficient consideration into, then the combinatorial testing is proposed to generate variable strength combinatorial test suite based on One-test-at-a-time strategy. At last test cases are minimized according to constraint rules. The results show that compared with conventional random testing, the proposed approach can detect more errors with the same amount of test cases which turning out to be more ideal than existing ones in size.

  15. Problems in Standardization of Orthodontic Shear Bond Strength Tests; A Brief Review

    Directory of Open Access Journals (Sweden)

    M.S. A. Akhoundi

    2005-03-01

    Full Text Available Bonding brackets to the enamel surface has gained much popularity today. New adhesive systems have been introduced and marketed and a considerable increase in research regarding bond strength has been published. A considerable amount of these studies deal with shear bond strength of adhesives designed for orthodontic purpose.Previous studies have used variety of test designs. This diversity in test design is due to the fact that there is no standard method for evaluating shear bond strength in orthodontics. Therefore comparison of data obtained from different study is almost impossible.This article tries to briefly discuss the developments occurred in the process of shear bond strength measurement of orthodontic adhesives with an emphasis on the type of test set up and load application.Although the test designs for measuring shear bond strength in orthodontics are still far from ideal, attempts must be made to standardize these tests especially in order to makecomparison of different data easier. It is recommended that test designs be set up in such a manner that better matches with the purpose of the study.

  16. Testing compression strength of wood logs by drilling resistance

    Science.gov (United States)

    Kalny, Gerda; Rados, Kristijan; Rauch, Hans Peter

    2017-04-01

    Soil bioengineering is a construction technique using biological components for hydraulic and civil engineering solutions, based on the application of living plants and other auxiliary materials including among others log wood. Considering the reliability of the construction it is important to know about the durability and the degradation process of the wooden logs to estimate and retain the integral performance of a soil bioengineering system. An important performance indicator is the compression strength, but this parameter is not easy to examine by non-destructive methods. The Rinntech Resistograph is an instrument to measure the drilling resistance by a 3 mm wide needle in a wooden log. It is a quasi-non-destructive method as the remaining hole has no weakening effects to the wood. This is an easy procedure but result in values, hard to interpret. To assign drilling resistance values to specific compression strengths, wooden specimens were tested in an experiment and analysed with the Resistograph. Afterwards compression tests were done at the same specimens. This should allow an easier interpretation of drilling resistance curves in future. For detailed analyses specimens were investigated by means of branch inclusions, cracks and distances between annual rings. Wood specimens are tested perpendicular to the grain. First results show a correlation between drilling resistance and compression strength by using the mean drilling resistance, average width of the annual rings and the mean range of the minima and maxima values as factors for the drilling resistance. The extended limit of proportionality, the offset yield strength and the maximum strength were taken as parameters for compression strength. Further investigations at a second point in time strengthen these results.

  17. Validation and Reliability of a Novel Test of Upper Body Isometric Strength.

    Science.gov (United States)

    Bellar, David; Marcus, Lena; Judge, Lawrence W

    2015-09-29

    The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a "push-up" style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (pIsometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment.

  18. Microtensile bond strength of three simplified adhesive systems to caries-affected dentin.

    Science.gov (United States)

    Scholtanus, J D; Purwanta, Kenny; Dogan, Nilgun; Kleverlaan, Cees J; Feilzer, Albert J

    2010-08-01

    The purpose of the study was to determine the microtensile bond strength of three different simplified adhesive systems to caries-affected dentin. Fifteen extracted human molars with primary carious lesions were ground flat until dentin was exposed. Soft caries-infected dentin was excavated with the help of caries detector dye. On the remaining hard dentin, a standardized smear layer was created by polishing with 600-grit SiC paper. Teeth were divided into three groups and treated with one of the three tested adhesives: Adper Scotchbond 1 XT (3M ESPE), a 2-step etch-andrinse adhesive, Clearfil S3 Bond (Kuraray), a 1-step self-etching or all-in-one adhesive, and Clearfil SE Bond (Kuraray), a 2-step self-etching adhesive. Five-mm-thick composite buildups (Z-250, 3M ESPE) were built and light cured. After water storage for 24 h at 37ºC, the bonded specimens were sectioned into bars (1.0 x 1.0 mm; n = 20 to 30). Microtensile bond strength of normal dentin specimens and caries-affected dentin specimens was measured in a universal testing machine (crosshead speed = 1 mm/min). Data were analyzed using two-way ANOVA and Tukey's post-hoc test (p adhesives were found. Adper Scotchbond 1 XT and Clearfil S3 Bond showed significantly lower bond strength values to caries-affected dentin. For Clearfil SE Bond, bond strength values to normal and caries-affected dentin were not significantly different. All the tested simplified adhesives showed similar bond strength values to normal dentin. For the tested 2-step etch-and-rinse adhesive and the all-in-one adhesive, the bond strength values to caries-affected dentin were lower than to normal dentin.

  19. Reliability of nondestructive testing of metal strength properties for power equipment

    International Nuclear Information System (INIS)

    Bugaj, N.V.; Lebedev, A.A.; Sharko, A.V.

    1985-01-01

    Ultrasonic control which is a constituent part of a complex control system which includes specimen-free (by hardness) tests, random breaking tests and acoustic measurements is stUdied for its reliability with respect to strength properties of power-equipment metal. Quantitative and alternative criteria are developed to estimate quality of elements for power-equipment according to results of metal strength properties. Acoustic control results are presented for ultimate strength in 12Kh1MF-steel

  20. The effects of adding molybdenum and niobium on the creep strength of 18Cr-10Ni-20Co austenitic steel

    International Nuclear Information System (INIS)

    Tomono, Yutaka

    1987-01-01

    The decrease in the creep strength of structural materials during service at elevated temperatures is a very important problem that affects the security of plants and machinery. The improvement in the creep strength of 18Cr-10Ni-20Co austenitic steel achieved through the addition of molybdenum and niobium was studied in tests carried out at 973K and 1,073K. The creep strengthening mechanism was examined using transmission electron micrographs, X-ray diffraction, etc. The results obtained are summarized as follows: (1) The creep strength of low C-18Cr-10Ni-20Co austenitic steel with molybdenum was greatly improved by the addition of niobium up to 1% by weight. In the case of long-term creep, no trend toward decreasing creep strength was observed. (2) The creep strength of austenitic steel possessing a matrix strengthened with molybdenum can be improved through the addition of niobium combined with precipitation hardening with fine carbides precipitated in the grains. (author)

  1. Effect of Body Mass Index on Postural Balance and Muscle Strength in Children Aged 8-10 years

    Directory of Open Access Journals (Sweden)

    Lucky Prasetiowati

    2017-04-01

    Full Text Available Background:Childhood overweight and obesity, which are considered as global epidemic, can be assessed using Body Mass Index (BMI. BMI difference can lead to anatomic changes due to an increased body load. This increase might also affect motor performance, including changes in postural balance and muscle strength. Aims and Objectives: to explain the influence of BMI on postural balance and lower limb muscle strength and to assess the correlation between those two variables in children aged 8-10 years. Material and methods:The sample consisted of 63 children aged 8-10 years, which were divided in 3 groups: BMI-normal, BMI-overweight, and BMI-obese. The postural balance was assessed using single leg balance test on MatScan and the Center Of Pressure (COP area was recorded. Isometric muscle strength of hip extensor and knee extensor were measured using a hand-held dynamometer. Results: Obese children had significantly largerCOP area than overweight (p = 0.004 and normal weight children (p = 0.000.There were no significant differences in hip extensor muscle strength between obese children with overweight and normal weight children (p=0.527. The absolute knee extensor muscle strength in obese group was significantly higher than the overweight and normal group (p = 0.003. However the relative muscle strength of lower limb for obese children was significantly lower than for normal weight. There was no significant correlation between absolute hip extensor and knee extensor muscles strength with COP area. Conclusion: Obese children have decreased postural balance and increased absolute knee extensormuscle strength significantly when compared to overweight and normal children. There is no significant correlation between postural balance and muscle strength.

  2. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain

    DEFF Research Database (Denmark)

    Rafn, Bolette S; Tang, Lars; Nielsen, Peter Martin

    2016-01-01

    OBJECTIVE: To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. DESIGN: Cross-sectional study. SETTING: Clinical assessments at Sports Orthopaedic Research...... Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. PARTICIPANTS: Twenty-four male soccer players with unilateral long-standing hip and groin pain. INTERVENTIONS: The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion...... strength (Spearman rho = -0.44, P = 0.016). CONCLUSIONS: Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain....

  3. Study on load test of 100m cross-reinforced deck type concrete box arch bridge

    Science.gov (United States)

    Shi, Jing Xian; Cheng, Ying Jie

    2018-06-01

    Found in the routine quality inspection of highway bridge that many vertical fractures on the main beam (10mT beam) of the steel reinforced concrete arch bridge near the hydropower station. In order to grasp the bearing capacity of this bridge under working conditions with cracks, the static load and dynamic load test of box arch bridge are carried out. The Midas civil theory is calculated by using the special plate trailer - 300 as the calculation load, and the deflection and stress of the critical section are tested by the equivalent cloth load in the test vehicle. The pulsation test, obstacles and no obstacle driving test were carried out. Experimental results show that the bridge under the condition of the test loads is in safe condition, main bearing component of the strength and stiffness meet the design requirements, the crack width does not increase, in the process of loading bridge overall work performance is good.

  4. Finite Element Simulation of Diametral Strength Test of Hydroxyapatite

    International Nuclear Information System (INIS)

    Ozturk, Fahrettin; Toros, Serkan; Evis, Zafer

    2011-01-01

    In this study, the diametral strength test of sintered hydroxyapatite was simulated by the finite element software, ABAQUS/Standard. Stress distributions on diametral test sample were determined. The effect of sintering temperature on stress distribution of hydroxyapatite was studied. It was concluded that high sintering temperatures did not reduce the stress on hydroxyapatite. It had a negative effect on stress distribution of hydroxyapatite after 1300 deg. C. In addition to the porosity, other factors (sintering temperature, presence of phases and the degree of crystallinity) affect the diametral strength of the hydroxyapatite.

  5. Influence of EDC on Dentin-Resin Shear Bond Strength and Demineralized Dentin Thermal Properties

    Directory of Open Access Journals (Sweden)

    Lin Tang

    2016-11-01

    Full Text Available This study aimed to evaluate the bonding strength and thermal properties of demineralized dentin with and without EDC treatment. Sound human molars were randomly divided into seven treatment groups (n = 20: control, 80% ethanol, and five EDC ethanol solutions (0.01–1.0 M. In each group, 16 samples were used for bond strength assessment and 4 samples were used for scanning electron microscopy (SEM analysis. A further 70 intact molars were used to obtain a fine demineralized dentin powder, treated with the same solutions and were evaluated the crosslink degree by ninhydrin test and denaturation temperature (Td by differential scanning calorimetry. EDC-treated specimens (<1.0 M had a higher bond strength, especially 0.3 and 0.5 M group, than the control counterpart. There was a significant drop in bond strength of 1.0 M EDC group. SEM revealed a homogeneous and regular interface under all treatments. EDC treatment significantly increased the demineralized dentin cross-link degree and Td compared with the control and ethanol treatments. The 0.3 and 0.5 M treatments showed the highest cross-link degree and Td. In terms of mechnical and theramal properties consideration, 0.3 and 0.5 M EDC solutions may be favorable for when applied with etch-and-rinse adhesives, but it is still needed further long-term study.

  6. Determination of the first hydrolysis constant of Europium (III) in 3 M of ionic strength

    International Nuclear Information System (INIS)

    Ramirez B, M.E.

    1994-01-01

    The first hydrolysis constant of Eu 3+ has been determined at 303 K and 3 M (NaCl) ionic strength. A solvent extraction method was used, the extractant was dibenzoylmethane in benzene and di glycolate anion in the aqueous phase provided competitive complexation. The tracer solution was 152m1 Eu (III) in water. The radioactive solution of europium was obtained by neutron irradiation of europium nitrate solutions at pH 3.0, in a TRIGA Mark III nuclear reactor at a neutron flux of 1 x 10 13 cm -2 s -1 . The half life of the produced isotope, 152m1 Eu (9.3 h), was verified by means of a Ge H detector and no interfering radiations were observed in the spectra. (Author)

  7. Analysis of the 30-m running speed test results in soccer players in third soccer leagues

    Directory of Open Access Journals (Sweden)

    Miłosz Drozd

    2018-04-01

    Full Text Available The basic goal of this study was to analysis of the results of the 30-m running speed test in soccer players in third soccer leagues. The study examined the group of randomly selected seventy athletes from two soccer teams from the Ekstraklasa league, two teams from the first league and two teams from the second leagues were randomized into the study group. All the measurements were performed in indoor arenas. The temperature in the arenas ranged from 22 to 24 C. Measurements were recorded in the morning (between 10:00 am and 12:00 am. The Running Speed Test was used in the study to diagnose speed potential in the athletes. The running speed was measured by means of a set of photocells located at 0m, 5m, 20m, 30m. The results obtained demonstrated that the elite-level matches are more dynamic since the players show higher values of speed parameters. Apart from starting speed, the results obtained for the distance of 5 m provide information for coaches concerning their work on special strength. The speed is indicated by the results obtained for 20 and 30 m distances, whereas flying measurements between 5/20m and 20/30m reflect inherited speed aptitudes.

  8. Influência do agente clareador peróxido de carbamida a 10% na resistência mecânica da colagem de braquetes ortodônticos Influence of 10% carbamide peroxide gel on the shear bond strength of orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Edgard Norões R. da Matta

    2005-04-01

    Full Text Available O propósito deste estudo in vitro foi determinar a influência do agente clareador peróxido de carbamida a 10% na resistência mecânica da colagem de braquetes ortodônticos. Foram estudados três grupos denominados G1 (não submetido ao clareamento, G2 (com clareamento e colagem realizada 1 semana após e G3 (com clareamento e colagem realizada 24h após. O teste de cisalhamento foi conduzido na máquina de ensaios mecânicos Emic, com a velocidade de deformação de 0,5 mm/min.A resitência ao cisalhamento em relação à área de colagem foi calculada para cada dente e expressa em MPa. Os resultados mostraram aumento estatisticamente significante (pThe purpose of this in vitro study was to determine the influence of 10% carbamide peroxide gel on the shear bond strength of orthodontic brackets. Three group were studied: G1 (without bleaching, G2 (bleaching and bonding after 1 week and G3 (bleaching and bonding after 24h. The shear test was conduced in a Emic testing machine with a crosshead speed of 0,5 mm/min. The shear bond strength was calculated for each tooth and expressed in MPa. The results show enhance statistical significant (p<0,001 on the shear bond strength after bleaching and encreased with the time interval between bleaching and bonding, significantily.

  9. Effects of surface treatments on bond strength of dental Ti-20Cr and Ti-10Zr alloys to porcelain

    International Nuclear Information System (INIS)

    Lin, Hsi-Chen; Wu, Shih-Ching; Ho, Wen-Fu; Huang, Ling-Hsiu; Hsu, Hsueh-Chuan

    2010-01-01

    The purpose of this study was to investigate the effect of surface treatments, including sandblasting and grinding, on the bond strength between a low-fusing porcelain and c.p. Ti, Ti-20Cr and Ti-10Zr alloys. The surface treatments were divided into 2 groups. Grinding surface treatment was applied to the first group, which served as the control, and sandblasting was applied to the second group. After treatment, low-fusing porcelain (Titankeramik) was fired onto the surface of the specimens. A universal testing machine was used to perform a 3-point bending test. The metal-ceramic interfaces were subjected to scanning electron microscopic analysis. Of the sandblasted samples, the debonding test showed that Ti-20Cr alloy had the strongest (31.50 MPa) titanium-ceramic bond (p < 005), followed by c.p. Ti (29.4 MPa) and Ti-10Zr (24.3 MPa). Of the grinded samples, Ti-20Cr alloy showed 27.3 MPa titanium-ceramic bond (p < 005), followed by c.p. Ti (14.3 MPa) and Ti-10Zr (failure). The SEM micrographs of the metal surface after debonding showed residual porcelain retained on all samples. On the whole, sandblasting surface treatment appears to have had a more beneficial effect on the Ti-ceramic bond strength than grinding surface treatment. Furthermore, surface treatment of Ti-20Cr with either grinding or sandblasting resulted in adequate bond strength, which exceeded the lower limit value in the ISO 9693 standard (25 MPa).

  10. Assessment of strength characteristics of Al2024 ECAP metal using small punch testing

    International Nuclear Information System (INIS)

    Ma, Young Wha; Choi, Jeong Woo; Yoon, Kee Bong; Kim, Seon Hwa

    2006-01-01

    When subjected to severe shear deformation by ECAP, microstructure of Al2024 becomes extremely refined. To measure the strength of that, Small Punch(SP) testing method was adopted as a substitute for the conventional uniaxial tensile testing because the size of material processed by ECAP were limited to ψ12 mm in transverse direction. SP tests were performed with specimens in longitudinal and transverse directions of Al2024 ECAP metal. For comparing the strength values with those assessed by SP tests, uniaxial tensile tests were also conducted with specimens in longitudinal direction. Failure surfaces of the tested SP specimens showed that failure mode was shear deformation and Al2024 ECAP metal has an anisotropy in strength. Thus, conventional equations proposed for assessing the strength characteristics were improper to assess those of Al2024 ECAP metal. In this paper a way of assessing the strength of Al2024 ECAP metal was proposed and was proven to be effective

  11. Validation and Reliability of a Novel Test of Upper Body Isometric Strength

    Directory of Open Access Journals (Sweden)

    Bellar David

    2015-09-01

    Full Text Available The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4% volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a “push-up” style position while tethered (stainless steel chain to a load cell (high frequency anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98 suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001 with all predictor variables attaining significance in the model (p<0.05. Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001. Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment.

  12. Validation and Reliability of a Novel Test of Upper Body Isometric Strength

    Science.gov (United States)

    Bellar, David; Marcus, Lena; Judge, Lawrence W.

    2015-01-01

    The purpose of the present investigation was to examine the association of a novel test of upper body isometric strength against a 1RM bench press measurement. Forty college age adults (n = 20 female, n = 20 male; age 22.8 ± 2.8 years; body height 171.6 ± 10.8 cm; body mass 73.5 ± 16.3 kg; body fat 23.1 ± 5.4%) volunteered for the present investigation. The participants reported to the lab on three occasions. The first visit included anthropometric measurements and familiarization with both the upper body isometric test and bench press exercise. The final visits were conducted in a randomized order, with one being a 1RM assessment on the bench press and the other consisting of three trials of the upper body isometric assessment. For the isometric test, participants were positioned in a “push-up” style position while tethered (stainless steel chain) to a load cell (high frequency) anchored to the ground. The peak isometric force was consistent across all three trials (ICC = 0.98) suggesting good reliability. Multiple regression analysis was completed with the predictors: peak isometric force, gender, against the outcome variable 1RM bench press. The analysis resulted in a significant model (r2 = 0.861, p≤0.001) with all predictor variables attaining significance in the model (p<0.05). Isometric peak strength had the greatest effect on the model (Beta = 5.19, p≤0.001). Results from this study suggest that the described isometric upper body strength assessment is likely a valid and reliable tool to determine strength. Further research is warranted to gather a larger pool of data in regard to this assessment. PMID:26557203

  13. Comparison of hydroxyapatite and dental enamel for testing shear bond strengths.

    Science.gov (United States)

    Imthiaz, Nishat; Georgiou, George; Moles, David R; Jones, Steven P

    2008-05-01

    To investigate the feasibility of using artificial hydroxyapatite as a future biomimetic laboratory substitute for human enamel in orthodontic bond strength testing by comparing the shear bond strengths and nature of failure of brackets bonded to samples of hydroxyapatite and enamel. One hundred and fifty hydroxyapatite discs were prepared by compression at 20 tons and fired in a furnace at 1300 degrees C. One hundred and five enamel samples were prepared from the buccal and palatal/lingual surfaces of healthy premolars extracted for orthodontic purposes. Orthodontic brackets were bonded to each sample and these were subjected to shear bond strength testing using a custom-made jig mounted in an Instron Universal Testing Machine. The force value at bond failure was obtained, together with the nature of failure which was assessed using the Adhesive Remnant Index. The mean shear bond strength for the enamel samples was 16.62 MPa (95 per cent CI: 15.26, 17.98) and for the hydroxyapatite samples 20.83 MPa (95 per cent CI: 19.68, 21.98). The difference between the two samples was statistically significant (p enamel samples scored 2 or 3, while 49 per cent of the hydroxyapatite samples scored 0 or 1. Hydroxyapatite was an effective biomimetic substrate for bond strength testing with a mean shear bond strength value (20.83 MPa) at the upper end of the normal range attributed to enamel (15-20 MPa). Although the difference between the shear bond strengths for hydroxyapatite and enamel was statistically significant, hydroxyapatite could be used as an alternative to enamel for comparative laboratory studies until a closer alternative is found. This would eliminate the need for extracted teeth to be collected. However, it should be used with caution for quantitative studies where true bond strengths are to be investigated.

  14. Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies

    Directory of Open Access Journals (Sweden)

    Laura AlveBastos

    2015-02-01

    Full Text Available Objectives The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. Materials and Methods Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE, the specific self-etching adhesive system (Adhesive System P90, 3M ESPE was used with and without pre-etching (Pre-etching/Silorane and Silorane groups. Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray, with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups, or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE (Three-step/Methacrylate group (n = 6. The restored teeth were sectioned into stick-shaped test specimens (1.0 × 1.0 mm, and coupled to a universal test machine (0.5 mm/min to perform microtensile testing. Results Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p < 0.05. However, it was not significantly different from Preetching/Silorane and Methacrylate groups. Conclusions Pre-etching increased bond strength of silorane-based composite specific adhesive system to dentin.

  15. Duration dependence test for rational speculative bubble: the strength and weakness

    OpenAIRE

    Ahmad, Mahyudin

    2012-01-01

    This review highlights the strength and weakness of duration dependence test used by Mokhtar, Nassir and Hassan (2006) to detect the rational speculative bubble in the Malaysian stock market. It is found that despite the test’s strength over the other tests, it is however sensitive to different specifications and therefore may produce contrasting results.

  16. OECD MMCI Small-Scale Water Ingression and Crust Strength tests (SSWICS) SSWICS-1 final data report, Rev. 1 February 10, 2003.; Report, Rev. 1

    International Nuclear Information System (INIS)

    Lomperski, S.; Farmer, M.T.; Kilsdonk, D.; Aeschlimann, B.

    2011-01-01

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure; and (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are being conducted to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium (∼φ30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. The issue of crust strength will be addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus will measure the fracture strength of the crust while under a thermal load created by a heating element beneath the crust. The two apparatuses used to measure the melt quench rate and crust strength are jointly referred to as SSWICS (Small-Scale Water Ingression and Crust Strength). This report describes results of the first water ingression test, designated SSWICS-1. The test investigated the quench behavior of a 15 cm deep, fully

  17. COMPARISON BETWEEN TEST METHODS TO DETERMINE WOOD EMBEDMENT STRENGTH PARALLEL TO THE GRAIN

    Directory of Open Access Journals (Sweden)

    Diego Henrique de Almeida

    Full Text Available ABSTRACT This study compares the test methods according to the ABNT NBR 7190:1997, EN 383:2007, ASTM D5764:2007, EUROCODE 5:2004, NDS:2001 standards in order to provide support to establish a new test method for determining the embedment strength of wood parallel to the grain. Parallel-to-grain tests were carried out for six wood species (Schizolobium amazonicum; Pinus elliottii; Pinus oocarpa; Hymenaea spp.; Lyptus(r: hybrid Eucalyptus grandis and Eucalyptus urophylla, and Goupia glabra using four diameters (8 mm, 10 mm, 12 mm and 16 mm for the metal pin fasteners (bolts. The experimental results obtained according to the EN 383:2007 standard were closer to the specific values for the metal-dowel connections design used by ABNT NBR 7190:1997, which are considered equal compression parallel to the grain. The use of maximum embedment force or the force causing displacement of 5 mm between the bolt and the test-piece as criteria for determining embedment strength for EN 383:2007 appears to be more appropriate than the criteria used by the Brazilian and American Standards.

  18. Test results of NREL 10M, special-purpose family of thin airfoils

    Energy Technology Data Exchange (ETDEWEB)

    Starcher, K.L.; Nelson, V.C.; Wei, Jun [West Texas A& M Univ., Canyon, TX (United States)

    1996-12-31

    Two 25 kW Carter Wind Systems were tested to determine performance differences between production blades and rotors with NREL Special Purpose Thin Airfoils. Blade design, mold preparation, blade production, and testing were conducted. Design tools were created for computer modeling of the blade. The blades had the same twist, taper, and length as production blades. Flap natural frequency was adjusted to be as similar as possible between rotors, as was blade mass, blade center of gravity and rotor moment of inertia. Data collected were; wind speed at hub height, blade root flap & edgewise loads, main shaft torque, azimuth position, teeter angle, yaw angle and electrical power. These data were collected at 128 Hertz for data sets of eight seconds. This data set was then written to hard disk and the cycle repeated resulting in a file containing five and one half minutes of data. A data run consisted of; preflight checkout/warm-up of equipment, preflight calibration/verification of all sensors on both turbines, collection of five files of data (about thirty minutes of data), post flight calibration/verification of sensors. During this high speed data collection period there were a total of twenty-four data runs collected. Data were collected for wind speeds in the range about 7, 10 and 13 m/s. A data matrix was filled for clean, medium and heavy surface roughness. Baseline power curves, parametric pitch variation runs to establish testing pitch settings, high speed data collection runs with and without applied surface roughness were completed and analyzed. Data were compared using simple arithmetic mean, Fast Fourier Transform (FFT) analysis, rainflow counting algorithms and wavelet analysis. The NREL airfoils showed much less sensitivity to surface roughness. There were minimal root bending load differences. Annual energy production during long term operation is being determined. 9 refs., 7 figs.

  19. Effect of Pelletized Coconut Fibre on the Compressive Strength of Foamed Concrete

    Directory of Open Access Journals (Sweden)

    Mohd Jaini Zainorizuan

    2016-01-01

    Full Text Available Foamed concrete is a controlled low density ranging from 400kg/m3 to 1800kg/m3, and hence suitable for the construction of buildings and infrastructures. The uniqueness of foamed concrete is does not use aggregates in order to retain low density. Foamed concrete contains only cement, sand, water and foam agent. Therefore, the consumption of cement is higher in producing a good quality and strength of foamed concrete. Without the present of aggregates, the compressive strength of foamed concrete can only achieve as high as 15MPa. Therefore, this study aims to introduce the pelletized coconut fibre aggregate to reduce the consumption of cement but able to enhance the compressive strength. In the experimental study, forty-five (45 cube samples of foamed concrete with density 1600kg/m3 were prepared with different volume fractions of pelletized coconut fibre aggregate. All cube samples were tested using the compression test to obtain compressive strength. The results showed that the compressive strength of foamed concrete containing 5%, 10%, 15% and 20% of pelletized coconut fibre aggregate are 9.6MPa, 11.4MPa, 14.6MPa and 13.4MPa respectively. It is in fact higher than the controlled foamed concrete that only achieves 9MPa. It is found that the pelletized coconut fibre aggregate indicates a good potential to enhance the compressive strength of foamed concrete.

  20. Tests of Hadronic Probes of GT Strength

    CERN Multimedia

    2002-01-01

    There are many important problems where one wishes to know the distribution of Gamow-Teller (GT) strength in circumstances where it cannot be measured directly (for example, because of energy-release limitations). Then one must rely on hadronic probes to infer the GT strength. It is therefore essential to test these probes as extensively as possible. The isospin-analog transitions in $^{37}$Ca $\\beta^{+}$ -decay and $^{37}$Cl$(p, n)$ provide an excellent ground for such a test. Recent $^{37}$Cl$ (p, n) $ studies, while qualitatively in agreement with our previous ISOLDE work on $^{37}$Ca $\\beta^{+} $ -decay, show quantitative discrepancies that appear to grow as the excitation energy in the residual nuclei increases. Because of the bulk of the GT strengh appears at these high excitation energies, it is important to extend the $\\beta$-decay data to even higher excitation energies where, because of rapidly diminishing phase-space, strong GT transitions correspond to very weak $\\beta$ -branches. We propose to do...

  1. Standard test method for compressive (crushing) strength of fired whiteware materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method covers two test procedures (A and B) for the determination of the compressive strength of fired whiteware materials. 1.2 Procedure A is generally applicable to whiteware products of low- to moderately high-strength levels (up to 150 000 psi or 1030 MPa). 1.3 Procedure B is specifically devised for testing of high-strength ceramics (over 100 000 psi or 690 MPa). 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  2. Evaluating Motoric Performance of 10 - 12 Age Group Football Players

    Directory of Open Access Journals (Sweden)

    Mehmet KUMARTAŞLI

    2014-08-01

    Full Text Available The aim of this study is to evaluate motoric perfromance of 10 - 12 age group football players. Akdeniz University tiny football team joined as experiment group and 80. Yıl Cumhuriyet Grammar School football team joined to the study as control group. An exercise programme with educational game format considering physical capacities and develeopment features was applied to the student as 8 weeks, 3 days a week. Standing long jump, flexibilty, 20 m. speed, handgrip strength, arm pull, vert ical jump, 10x5 shuttle run and leg strength tests were applied to the students. Handled data were compared at SPSS 10 statistic programme by using Independent Sample t Test. Students’ lenght and weight measurements were calculated. As a result of measurem ents, there were not found diffrences between experimental and control group’s standing long jump, flexibilty, 20 m. speed, handgrip strength, a vertical jump, 10x5 shuttle run and leg strength tests (p>0,05; but in arm pull test, statistically difference was found (p<0,01. While evaluating the physical performance in cihldren and adolescents, growth process is had to be considered. The results of football players that exercise regularly from small ages at physical and physiologic measurements have an importance according to their age. Performance observed in children is sudden and temporary. There are a few studies in the literature about negative psycological effects of starting trainings in early ages.

  3. Comparison of Weibull strength parameters from flexure and spin tests of brittle materials

    Science.gov (United States)

    Holland, Frederic A., Jr.; Zaretsky, Erwin V.

    1991-01-01

    Fracture data from five series of four point bend tests of beam and spin tests of flat annular disks were reanalyzed. Silicon nitride and graphite were the test materials. The experimental fracture strengths of the disks were compared with the predicted strengths based on both volume flaw and surface flaw analyses of four point bend data. Volume flaw analysis resulted in a better correlation between disks and beams in three of the five test series than did surface flaw analysis. The Weibull (moduli) and characteristic gage strengths for the disks and beams were also compared. Differences in the experimental Weibull slopes were not statistically significant. It was shown that results from the beam tests can predict the fracture strength of rotating disks.

  4. Strength and deformability of hollow concrete blocks: correlation of block and cylindrical sample test results

    OpenAIRE

    Barbosa, C. S.; Hanai, J.B.

    2009-01-01

    This paper deals with correlations among mechanical properties of hollow blocks and those of concrete used to make them. Concrete hollow blocks and test samples were moulded with plastic consistency concrete, to assure the same material in all cases, in three diferente levels of strength (nominally 10 N/mm², 20 N/mm² and 30 N/mm²). The mechanical properties and structural behaviour in axial compression and tension tests were determined by standard tests in blocks and cylinders. Stress and str...

  5. Wide Panel Testing Technique for Evaluating Repair Weld Strengths

    Science.gov (United States)

    Rogers, Patrick R.; Bynum, Julian E.; Shah, Sandeep R.

    1998-01-01

    This paper describes a new tensile testing technique for evaluating the overall effect of a repair weld on the strength of a welded joint. Previously, repair weld strengths have been evaluated using one-inch width tensile specimens, but this technique does not capture all of the effects that result from a repair. The new technique involves testing of "wide panel" tensile specimens which contain the full length of a repair weld within a longer initial weld, allowing the specimen to capture the combined effects of residual stresses, local strength degradation, and load redistribution around a repair. The development of strains in the repair area of standard aluminum alloy specimens and new high-performance aluminum-lithium alloy specimens was observed and evaluated using photoelastic material. The results of this evaluation show an increased sensitivity to repair welding residual stresses in the aluminum-lithium alloy specimens.

  6. Reliability of the Handgrip Strength Test in Elderly Subjects With Parkinson Disease.

    Science.gov (United States)

    Villafañe, Jorge H; Valdes, Kristin; Buraschi, Riccardo; Martinelli, Marco; Bissolotti, Luciano; Negrini, Stefano

    2016-03-01

    The handgrip strength test is widely used by clinicians; however, little has been investigated about its reliability when used in subjects with Parkinson disease (PD). The purpose of this study was to investigate the test-retest reliability of the handgrip strength test for subjects with PD. The PD group consisted of 15 patients, and the control group consisted of 15 healthy subjects. Each patient performed 3 pain-free maximal isometric contractions on each hand on 2 occasions, 1 week apart. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and 95% limits of agreement (LOA) were calculated. The 2-way analysis of variance (ANOVA) was conducted to determine the differences between sides and groups. Test-retest reliability of measurements of grip strength was excellent for dominant (ICC = 0.97; P = .001) and non-dominant (ICC = 0.98; P = .001) hand of participant with PD and (ICC = 0.99; P = .001) and (ICC = 0.99; P = .001) respectively, of healthy group. The Jamar hand dynamometer had fair to excellent test-retest reliability to test grip strength in participants with PD.

  7. Comparison between two motor tests used for muscular strength/endurance analysis

    Directory of Open Access Journals (Sweden)

    Matheus Amarante do Nascimento

    2013-04-01

    Full Text Available The aim of this study was to compare motor performance in modified pull-up (MPUand flexed knee push-up (FKPU tests in young women. Thirty-five apparently healthy women (20.1±2.2 years were submitted to each one of the tests at an interval of48 hours in a random balanced design. Most individuals performed between 0 an d 10 repetitions (86% of the MPU test, and approximately 17% did not perform even one repetitions. On the other hand, the highest prevalence of outcomes for the FKPUtest was between 16 and 35 repetitions (71%. The Wilcoxon test identified statistically significant differences (p MPU. A moderate agreement (kappa =0.40 was found between the performance in both tests. Negative correlations of low magnitude (r=-0.23 to 0.46 were found between morphological variables (body weight,height, fat mass, and lean body mass and motor performance in both tests. The results suggest that the FKPU test is presented as a better indicator ofmuscular endurance levels, where as the MPU test seems to better discriminate muscular strength in young women.

  8. Flexural and diametral tensile strength of composite resins

    Directory of Open Access Journals (Sweden)

    Álvaro Della Bona

    2008-03-01

    Full Text Available This study evaluated the flexural strength (sf and the diametral tensile strength (st of light-cured composite resins, testing the hypothesis that there is a positive relation between these properties. Twenty specimens were fabricated for each material (Filtek Z250- 3M-Espe; AM- Amelogen, Ultradent; VE- Vit-l-escence, Ultradent; EX- Esthet-X, Dentsply/Caulk, following ISO 4049 and ANSI/ADA 27 specifications and the manufacturers’ instructions. For the st test, cylindrical shaped (4 mm x 6 mm specimens (n = 10 were placed with their long axes perpendicular to the applied compressive load at a crosshead speed of 1.0 mm/min. The sf was measured using the 3-point bending test, in which bar shaped specimens (n = 10 were tested at a crosshead speed of 0.5 mm/min. Both tests were performed in a universal testing machine (EMIC 2000 recording the fracture load (N. Strength values (MPa were calculated and statistically analyzed by ANOVA and Tukey (a = 0.05. The mean and standard deviation values (MPa were Z250-45.06 ± 5.7; AM-35.61 ± 5.4; VE-34.45 ± 7.8; and EX-42.87 ± 6.6 for st; and Z250-126.52 ± 3.3; AM-87.75 ± 3.8; VE-104.66 ± 4.4; and EX-119.48 ± 2.1 for sf. EX and Z250 showed higher st and sf values than the other materials evaluated (p < 0.05, which followed a decreasing trend of mean values. The results confirmed the study hypothesis, showing a positive relation between the material properties examined.

  9. Observations in the statistical analysis of NBG-18 nuclear graphite strength tests

    International Nuclear Information System (INIS)

    Hindley, Michael P.; Mitchell, Mark N.; Blaine, Deborah C.; Groenwold, Albert A.

    2012-01-01

    Highlights: ► Statistical analysis of NBG-18 nuclear graphite strength test. ► A Weibull distribution and normal distribution is tested for all data. ► A Bimodal distribution in the CS data is confirmed. ► The CS data set has the lowest variance. ► A Combined data set is formed and has Weibull distribution. - Abstract: The purpose of this paper is to report on the selection of a statistical distribution chosen to represent the experimental material strength of NBG-18 nuclear graphite. Three large sets of samples were tested during the material characterisation of the Pebble Bed Modular Reactor and Core Structure Ceramics materials. These sets of samples are tensile strength, flexural strength and compressive strength (CS) measurements. A relevant statistical fit is determined and the goodness of fit is also evaluated for each data set. The data sets are also normalised for ease of comparison, and combined into one representative data set. The validity of this approach is demonstrated. A second failure mode distribution is found on the CS test data. Identifying this failure mode supports the similar observations made in the past. The success of fitting the Weibull distribution through the normalised data sets allows us to improve the basis for the estimates of the variability. This could also imply that the variability on the graphite strength for the different strength measures is based on the same flaw distribution and thus a property of the material.

  10. In-vitro orthodontic bond strength testing : A systematic review and meta-analysis

    NARCIS (Netherlands)

    Finnema, K.J.; Ozcan, M.; Post, W.J.; Ren, Y.J.; Dijkstra, P.U.

    INTRODUCTION: The aims of this study were to systematically review the available literature regarding in-vitro orthodontic shear bond strength testing and to analyze the influence of test conditions on bond strength. METHODS: Our data sources were Embase and Medline. Relevant studies were selected

  11. Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies.

    Science.gov (United States)

    Bastos, Laura Alves; Sousa, Ana Beatriz Silva; Drubi-Filho, Brahim; Panzeri Pires-de-Souza, Fernanda de Carvalho; Garcia, Lucas da Fonseca Roberti

    2015-02-01

    The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesive system (Adhesive System P90, 3M ESPE) was used with and without pre-etching (Pre-etching/Silorane and Silorane groups). Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE) were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray), with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups), or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE) (Three-step/Methacrylate group) (n = 6). The restored teeth were sectioned into stick-shaped test specimens (1.0 × 1.0 mm), and coupled to a universal test machine (0.5 mm/min) to perform microtensile testing. Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p adhesive system to dentin.

  12. Associations of maximal strength and muscular endurance test scores with cardiorespiratory fitness and body composition.

    Science.gov (United States)

    Vaara, Jani P; Kyröläinen, Heikki; Niemi, Jaakko; Ohrankämmen, Olli; Häkkinen, Arja; Kocay, Sheila; Häkkinen, Keijo

    2012-08-01

    The purpose of the present study was to assess the relationships between maximal strength and muscular endurance test scores additionally to previously widely studied measures of body composition and maximal aerobic capacity. 846 young men (25.5 ± 5.0 yrs) participated in the study. Maximal strength was measured using isometric bench press, leg extension and grip strength. Muscular endurance tests consisted of push-ups, sit-ups and repeated squats. An indirect graded cycle ergometer test was used to estimate maximal aerobic capacity (V(O2)max). Body composition was determined with bioelectrical impedance. Moreover, waist circumference (WC) and height were measured and body mass index (BMI) calculated. Maximal bench press was positively correlated with push-ups (r = 0.61, p strength (r = 0.34, p strength correlated positively (r = 0.36-0.44, p test scores were related to maximal aerobic capacity and body fat content, while fat free mass was associated with maximal strength test scores and thus is a major determinant for maximal strength. A contributive role of maximal strength to muscular endurance tests could be identified for the upper, but not the lower extremities. These findings suggest that push-up test is not only indicative of body fat content and maximal aerobic capacity but also maximal strength of upper body, whereas repeated squat test is mainly indicative of body fat content and maximal aerobic capacity, but not maximal strength of lower extremities.

  13. Use of combined destructive and non-destructive test methods to assess the strength of concrete

    Energy Technology Data Exchange (ETDEWEB)

    Arioz, O. [Optimizing Consultancy, Izmir (Turkey); Kilinc, K. [Kirklareli University, Department of Civil Engineering, Kirklareli (Turkey); Ramyar, K. [Ege University, Department of Civil Engineering, Ismir (Turkey); Tuncan, M.; Tuncan, A. [Anadolu University, Department of Civil Engineering, Eskişehir (Turkey)

    2013-07-01

    The compressive strength test applied on standard samples is one of the most important tests indicating the quality of concrete in structures. The results of the standard tests are compared with the values used in design calculations and the quality of concrete is controlled. Although the standard tests are well accepted by the construction industry, they may not represent the in-situ strength of concrete due to the differences between the degree of compaction and curing conditions of concrete and those of standard samples. In-situ strength is also important for the efficient planning of the construction works in huge projects. In the present study, the results obtained from standard tests, core tests, ultrasonic pulse velocity tests, and rebound hammer tests were extensively analysed for the assessment of concrete strength. Key words: Concrete strength, standard tests, core test, ultrasonic pulse velocity, rebound number.

  14. The role of self-control strength in the development of state anxiety in test situations.

    Science.gov (United States)

    Englert, C; Bertrams, A

    2013-06-01

    Self-control strength may affect state anxiety because emotion regulation is impaired in individuals whose self-control strength has been temporarily depleted. Increases in state anxiety were expected to be larger for participants with depleted compared to nondepleted self-control strength, and trait test anxiety should predict increases in state anxiety more strongly if self-control strength is depleted. In a sample of 76 university students, trait test anxiety was assessed, self-control strength experimentally manipulated, and state anxiety measured before and after the announcement of a test. State anxiety increased after the announcement. Trait test anxiety predicted increases in state anxiety only in students with depleted self-control strength, suggesting that increased self-control strength may be useful for coping with anxiety.

  15. The use of maturity method in estimating concrete strength

    International Nuclear Information System (INIS)

    Salama, A.E.; Abd El-Baky, S.M.; Ali, E.E.; Ghanem, G.M.

    2005-01-01

    Prediction of the early age strength of concrete is essential for modernized concrete for construction as well as for manufacturing of structural parts. Safe and economic scheduling of such critical operations as form removal and re shoring, application of post-tensioning or other mechanical treatment, and in process transportation and rapid delivery of products all should be based upon a good grasp of the strength development of the concrete in use. For many years, it has been proposed that the strength of concrete can be related to a simple mathematical function of time and temperature so that strength could be assessed by calculation without mechanical testing. Such functions are used to compute what is called the m aturity o f concrete, and the computed value is believed to obtain a correlation with the strength of concrete. With its simplicity and low cost, the application of maturity concept as in situ testing method has received wide attention and found its use in engineering practice. This research work investigates the use of M aturity method' in estimating the concrete strength. An experimental program is designed to estimate the concrete strength by using the maturity method. Using different concrete mixes, with available local materials. Ordinary Portland Cement, crushed stone, silica fume, fly ash and admixtures with different contents are used . All the specimens were exposed to different curing temperatures (10, 25 and 40 degree C), in order to get a simplified expression of maturity that fits in with the influence of temperature. Mix designs and charts obtained from this research can be used as guide information for estimating concrete strength by using the maturity method

  16. SHORT- AND LONG-TERM BOND STRENGTHS OF A GOLD STANDARD

    Directory of Open Access Journals (Sweden)

    Safa TUNCER

    2015-04-01

    Full Text Available Purpose: The aim of this study was to investigate the micro tensile bond strength of a self-etch adhesive system following 1 year storage in water. Materials and Methods: 10 sound human molar teeth were used for micro tensile bond strength test. Twostep self-etch dentin adhesive (Clearfil SE Bond® was applied to the flat dentin surfaces according to the manufacturer’s instructions. Composite blocks (Z- 250; 3M ESPE of 5 mm in height have been prepared by using layering technique. Teeth were stored in water for 24 hours at 37°C and longitudinally sectioned to obtain dentin sticks of 1 mm2.Randomly selected samples from half of the teeth were immediately subjected to micro tensile test and. Remaining specimens were tested after 1 year storage in water. Bond strengths were calculated in megapascal (MPa. Results: Means and standard deviations of the Clearfil SE Bond® micro tensile bond strength values were, respectively, 37.31 ± 13.77 MPa and 24.78 ± 2.99 MPa after 24 h and 1 year of storage in water. The difference was statistically significant (p=0.031. Conclusion: Long-term storage in water decreased the micro tensile bond strength values of the twostep self-etch adhesive which has been accepted as the gold standard in bond strength tests.

  17. Means of Speed-Strength Abilities Development in Physical Training Classes with 10th Graders

    Directory of Open Access Journals (Sweden)

    С. А. Пашкевич

    2016-08-01

    Full Text Available The purpose of the research is to determine the means of development of speed-strength abilities manifesting in jump-offs in jumping exercises in classes with the 10th graders in order to improve the compliance with the standards of physical preparedness. Materials and methods. Analysis and collation of scientific and methodological literature, special preparedness testing, methods of mathematical statistics. The participants in the experiment were eight 10th-grade boys who turned fifteen or sixteen at the time of the experiment. Research results. During the experiment, we used the following tests: standing long jump, 30‑meter race from the standing start, standing triple jump. We suggested that the pupils perform special exercises: jumping on two legs and pulling up bent legs to the chest, repeated jumps on two legs over obstacles, jumping on two legs over the gymnastic bench while moving along the bench, jumping off a 60-70-cm height landing in half-squat, jumping off a 30-40-cm height onto two legs followed by a jump over obstacles (3-4 low barriers. Conclusions. When performing jumping exercises, it is necessary to create conditions for the reactive-ballistic type of muscle contractions. Experimental exercises were selected by the criteria of “the dynamic compliance principle” to correspond, fully or partly, to the nature of motor activity: motor structure, jump-off biodynamics, muscle tension regime, peculiarities of manifestation of speed-strength abilities.

  18. Electron impact collision strengths and transition rates for extreme ultraviolet emission from Xe10+

    International Nuclear Information System (INIS)

    Shen Yunfeng; Gao Cheng; Zeng Jiaolong

    2009-01-01

    The energy levels, oscillator strengths, and electron impact collision strengths are calculated for the Xe 10+ ion using the configuration interaction scheme implemented by the Flexible Atomic Code. These data pertain to the 3917 levels belonging to the following configurations: 4s 2 4p 6 4d 8 , 4s 2 4p 6 4d 7 4f, 4s 2 4p 6 4d 7 5l (l = s, p, d, or f), 4s 2 4p 5 4d 9 , 4s 2 4p 5 4d 8 4f, 4s 2 4p 5 4d 8 5l, 4s 2 4p 6 4d 6 5s5p, 4s 2 4p 6 4d 6 5p5d. Configuration interactions among these configurations are included in the calculation. Collision strengths are obtained at 10 scattered electron energies (1-1000 eV) and are tabulated here at five representative energies of 10, 50, 100, 500, and 1000 eV. Effective collision strengths are obtained by assuming a Maxwellian electron velocity distribution at 10 temperatures ranging from 10 to 100 eV, and are tabulated at five representative temperatures of 10, 30, 50, 70 and 100 eV in this work. The whole data set should be useful for research involving extreme ultraviolet emission from Xe 10+

  19. Salt-saturated concrete strength and permeability

    International Nuclear Information System (INIS)

    Pfeifle, T.W.; Hansen, F.D.; Knowles, M.K.

    1996-01-01

    Laboratory-scale experiments applicable to the use of salt-saturated concrete as a seal material for a transuranic waste repository have been completed. Nitrogen gas permeability measurements were made using a flexible-wall permeameter, a confining pressure of 1 MPa, and gas pressure gradients ranging from 0.3 MPa to 0.75 MPa. Results show that salt-saturated concrete has very low intrinsic permeability with values ranging from 9.4 x 10 -22 m 2 to 9.7 x 10 -17 m 2 . Strength and deformation characteristics were investigated under conditions of triaxial compression with confining pressures ranging from 0 to 15 MPa using either axial strain-rate or axial stress-rate control and show that the failure strength of concrete increases with confining pressure which can be adequately described through pressure-sensitive failure criteria. Axial, radial, and volumetric strains were also measured during each test and these data were used to determine elastic properties. Experimental results are applicable in the design and analysis of scale-related functions and apply to other concrete structures subjected to compressive loadings such as dams and prestressed structural members

  20. Bond strength test of acrylic artificial teeth with prosthetic base

    Directory of Open Access Journals (Sweden)

    Erna Kurnikasari

    2008-07-01

    Full Text Available Denture consists of acrylic artificial teeth and acrylic prothesis base bond chemically with a bond strength of 315 kgF/cm2. Most of the commercial acrylic artificial teeth do not specify their specifications and all of those acrylic artificial teeth do not include mechanical data (bond strength. The aim of this study is to discover which acrylic artificial teeth meet ADA specification no. 15. This study is a descriptive analytic study performed to 5 acrylic artificial teeth posterior brands commonly used by dentists and technicians. From each brand, 3 sample teeth were taken. The acrylic artificial teeth were prepared into a rectangular shape and were attached between acrylic prothesis base simulation and jigs. The sample was given tensile load using a Universal Testing Machine. The amount of force that causes the teeth to be fractured was recorded and the bond strength was calculated. The results of the study show that the average value for the five acrylic artificial teeth for the five brands were as followed: Brand A, 125.993 kgF/cm2; B, 188.457 kgF/cm2; C, 175.880 kgF/cm2; D, 153.373 kgF/cm2; E, 82.839 kgF/cm2. The data can be tested statistically by using One Way ANOVA test and Dunnett test (alpha = 0.05. From the study, it is concluded that the five acrylic artificial teeth have a bond strength below the ADA specification no. 15.

  1. Drying time of tray adhesive for adequate tensile bond strength between polyvinylsiloxane impression and tray resin material.

    Science.gov (United States)

    Yi, Myong-Hee; Shim, Joon-Sung; Lee, Keun-Woo; Chung, Moon-Kyu

    2009-07-01

    Use of custom tray and tray adhesive is clinically recommended for elastomeric impression material. However there is not clear mention of drying time of tray adhesive in achieving appropriate bonding strength of tray material and impression material. This study is to investigate an appropriate drying time of tray adhesives by evaluating tensile bonding strength between two types of polyvinylsiloxane impression materials and resin tray, according to various drying time intervals of tray adhesives, and with different manufacturing company combination of impression material and tray adhesive. Adhesives used in this study were Silfix (Dentsply Caulk, Milford, Del, USA) and VPS Tray Adhesive (3M ESPE, Seefeld, Germany) and impression materials were Aquasil Ultra (monophase regular set, Dentsply Caulk, Milford, Del, USA) and Imprint II Garant (regular body, 3M ESPE, Seefeld, Germany). They were used combinations from the same manufacture and exchanged combinations of the two. The drying time was designed to air dry, 5 minutes, 10 minutes, 15 minutes, 20 minutes, and 25 minutes. Total 240 of test specimens were prepared by auto-polymerizing tray material (Instant Tray Mix, Lang, Wheeling, Il, USA) with 10 specimens in each group. The specimens were placed in the Universal Testing machine (Instron, model 3366, Instron Corp, University avenue, Nowood, MA, USA) to perform the tensile test (cross head speed 5 mm/min). The statistically efficient drying time was evaluated through ANOVA and Scheffe test. All the tests were performed at 95% confidence level. The results revealed that at least 10 minutes is needed for Silfix-Aquasil, and 15 minutes for VPS Tray Adhesive-Imprint II, to attain an appropriate tensile bonding strength. VPS Tray Adhesive-Imprint II had a superior tensile bonding strength when compared to Silfix-Aquasil over 15 minutes. Silfix-Aquasil had a superior bonding strength to VPS Tray Adhesive-Aquasil, and VPS Tray Adhesive-Imprint II had a superior tensile

  2. THE EFFECT OF VOLUME VARIATION OF SILVER NANOPARTICLE SOLUTION TOWARDS THE POROSITY AND COMPRESSIVE STRENGTH OF MORTAR

    Directory of Open Access Journals (Sweden)

    W.S.B. Dwandaru

    2016-10-01

    Full Text Available As the world is growing rapidly, people need better building materials such as mortar. The aim of this research is to determine the effect of adding silver nanoparticle solution towards the porosity and compressive strength of mortar. This research was started by making silver nanoparticle solution from nitrate silver (AgNO3. The solution is then characterized using Uv-Vis spectrophotometer. 5 mM silver nanoparticle is added in the process of mortar production with volume variation of the silver nanoparticle solution. The porosity, compressive strength, and the content of mortar were determined by digital scale, universal testing machine, and X-ray diffraction, respectively. For silver nanoparticle solution volumes of (in mL 0, 5, 10, 15, 20, and 25 the porosity obtained are (in % 20.38, 19.48, 19.42, 18.9, 17.8, and 17.5, respectively. The best increase in compressive strength is obtained for (in MPa 29,068, 29,308, and 31,385, with nanoparticle solution volumes of (in mL 5, 10, and 15   Keywords: mortar, silver nanoparticle, compressive strength

  3. Evaluating resin-enamel bonds by microshear and microtensile bond strength tests: effects of composite resin

    Science.gov (United States)

    de ANDRADE, Andrea Mello; MOURA, Sandra Kiss; REIS, Alessandra; LOGUERCIO, Alessandro Dourado; GARCIA, Eugenio Jose; GRANDE, Rosa Helena Miranda

    2010-01-01

    Objectives The aims of this study were to evaluate the effect of resin composite (Filtek Z250 and Filtek Flow Z350) and adhesive system [(Solobond Plus, Futurabond NR (VOCO) and Adper Single Bond (3M ESPE)] on the microtensile (µTBS) and microshear bond strength (µSBS) tests on enamel, and to correlate the bond strength means between them. Material and methods Thirty-six extracted human molars were sectioned to obtain two tooth halves: one for µTBS and the other one for µSBS. Adhesive systems and resin composites were applied to the enamel ground surfaces and light-cured. After storage (37ºC/24 h) specimens were stressed (0.5 mm/ min). Fracture modes were analyzed under scanning electron microscopy. The data were analyzed using two-way ANOVA and Tukey's test (α=0.05). Results The correlation between tests was estimated with Pearson's product-moment correlation statistics (α =0.05). For both tests only the main factor resin composite was statistically significant (padhesives. Both microbond tests seem to be positive and linearly correlated and can therefore lead to similar conclusions. PMID:21308290

  4. Indigenous Design for Automatic Testing of Tensile Strength Using Graphical User Interface

    OpenAIRE

    Ali Rafay; Junejo Faraz; Imtiaz Rafey; Shamsi Usama Sultan

    2016-01-01

    Tensile Testing is a fundamental material test to measure the tenacity and tensile strength. Tensile strength means ability to take tensile stress. This Universal Testing Machine is designed using Dual Cylinder Technique in order to comply with the maximun load (tensile force) with the reduction of minimum physical effort and minimized losses.It is to provide material testing opportunity to the students of different institutions, locally and globally, at lowest price; so that they can have a ...

  5. TOUGHREACT Testing in High Ionic Strength Brine Sandstone Systems

    International Nuclear Information System (INIS)

    Xu, Tianfu

    2008-01-01

    Deep saline formations and oil and gas reservoirs often contain concentrated brine solutions of ionic strength greater than 1 (I > 1 M). Geochemical modeling, involving high ionic strength brines, is a challenge. In the original TOUGHREACT code (Xu et al., 2004; Xu et al., 2006), activity coefficients of charged aqueous species are computed using an extended Debye-Huckel (DH) equation and parameters derived by Helgeson et al. (1981). The DH model can deal with ionic strengths from dilute to moderately saline water (up to 6 molal for an NaCl-dominant solution). The equations implemented for the DH model are presented in Appendix A. During the course of the Yucca Mountain project, a Pitzer ion-interaction model was implemented into TOUGHREACT. This allows the application of this simulator to problems involving much more concentrated aqueous solutions, such as those involving geochemical processes in and around high-level nuclear waste repositories where fluid evaporation and/or boiling is expected to occur (Zhang et al., 2007). The Pitzer ion-interaction model, which we refer to as the Pitzer virial approach, and associated ion-interaction parameters have been applied successfully to study non-ideal concentrated aqueous solutions. The formulation of the Pitzer model is presented in Appendix B; detailed information can be founded in Zhang et al. (2007). For CO 2 geological sequestration, the Pitzer ion-interaction model for highly concentrated brines was incorporated into TOUGHREACT/ECO2N, then was tested and compared with a previously implemented extended Debye-Hueckel (DH) ion activity model. The comparison was made through a batch geochemical system using a Gulf Coast sandstone saline formation

  6. PM alloy 625M for high strength corrosion resistant applications

    International Nuclear Information System (INIS)

    Rizzo, F.J.; Floreen, S.

    1997-06-01

    In applications where the combination of high strength and good corrosion resistance are required, there have been only a few alloys of choice. A new powder metallurgy alloy has been developed, PM 625M, a niobium modification of Alloy 625, as a material to fill this need. One area of particular interest is the nuclear power industry, where many problems have been encountered with bolts, springs, and guidepins. Mechanical properties and stress corrosion cracking data of PM 625M are presented in this paper

  7. Enamel Deproteinization using Papacarie and 10% Papain Gel on Shear Bond Strength of Orthodontic Brackets Before and After Acid Etching.

    Science.gov (United States)

    Agarwal, R M; Yeluri, R; Singh, C; Munshi, A K

    2015-01-01

    To suggest Papacarie(®) as a new deproteinizing agent in comparison with indigenously prepared 10% papain gel before and after acid etching that may enhance the quality of the bond between enamel surface and composite resin complex. One hundred and twenty five extracted human premolars were utilized and divided into five groups: In the group 1, enamel surface was etched and primer was applied. In group 2, treatment with papacarie(®) for 60 seconds followed by etching and primer application. In group 3, etching followed by treatment with papacarie(®) for 60 seconds and primer application. In group 4, treatment with 10% papain gel for 60 seconds followed by etching and primer application. In group 5, etching followed by treatment with 10% papain gel for 60 seconds and primer application . After bonding the brackets, the mechanical testing was performed using a Universal testing machine. The failure mode was analyzed using an adhesive remnant index. The etching patterns before and after application of papacarie(®) and 10% papain gel was also evaluated using SEM. The values obtained for shear bond strength were submitted to analysis of variance and Tukey test (p Adhesive remnant index no statistical difference was seen between the groups (p=0.538). Papacarie(®) or 10% papain gel can be used to deproteinize the enamel surface before acid etching to enhance the bond strength of orthodontic brackets.

  8. Fracture strength testing of crowns made of CAD/CAM composite resins.

    Science.gov (United States)

    Okada, Ryota; Asakura, Masaki; Ando, Akihiro; Kumano, Hirokazu; Ban, Seiji; Kawai, Tatsushi; Takebe, Jun

    2018-03-28

    The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3kN to 3.9kN, and was similar to that of IPS (3.3kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175MPa to 247MPa, and was significantly lower than that of IPS (360MPa). All CAD/CAM composite resin crowns studied presented about 3-4 times higher fracture strength than the average maximum bite force of the molar tooth (700-900N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  9. Solar cell contact pull strength as a function of pull-test temperature

    Science.gov (United States)

    Yasui, R. K.; Berman, P. A.

    1972-01-01

    Four types of solar cell contacts were given pull-strength tests at temperatures between -173 and +165 C. Contacts tested were: (1) solder-coated titanium-silver contacts on n-p cells, (2) palladium-containing titanium-silver contacts on n-p cells, (3) titanium-silver contacts on 0.2-mm-thick n-p cells, and (4) solder-coated electroless-nickel-plated contacts on p-n cells. Maximum pull strength was demonstrated at temperatures significantly below the air mass zero cell equilibrium temperature of +60 C. At the lowest temperatures, the chief failure mechanism was silicon fracture along crystallographic planes; at the highest temperatures, it was loss of solder strength. In the intermediate temperatures, many failure mechanisms operated. Pull-strength tests give a good indication of the suitability of solar cell contact systems for space use. Procedures used to maximize the validity of the results are described.

  10. Influence of dentinal regions on bond strengths of different adhesive systems.

    Science.gov (United States)

    Ozer, F; Unlü, N; Sengun, A

    2003-06-01

    This in vitro study assessed comparatively the shear bond strengths of three composite resins, 3M Valux Plus (3MVP), Herculite (H), Clearfil AP-X (CAP-X), a polyacid modified composite resin Dyract (D), and a resin modified glass-ionomer materials Vitremer (V), to cervical and buccal dentine regions of extracted human molar teeth. Four different bonding systems, 3M ScotchBond Multipurpose (SB), Clearfil Liner Bond 2 (LB2), Opti Bond (OB), and Prime & Bond 2.1 (PB 2.1) were used with the manufacturer's respective composite and compomer materials. One hundred freshly extracted mandibular molar teeth were selected for this study. Flat buccal dentine surfaces were created on 50 teeth and cylindrical rods of the five materials were bonded to the dentine surfaces. For assessment of cervical bond strengths, the materials were bonded to mesial and distal enamel bordered occlusal dentinal surfaces of the remaining 50 teeth. The five groups of restorative procedures were applied as follows; Group 1: SB + 3MVP, Group 2: LB2 + CAP-X, Group 3: OB + H, Group 4: PB2.1 + D, Group 5: Vitremer primer (VP) VP + V. Each restorative procedure thus had 20 specimens (10 buccal + 10 cervical). After 24 h of water storage (37 degrees C), the specimens were tested on a Universal Testing machine in shear with a cross head speed of 0.5 mm min-1. The bond strength values were calculated in MPa and the results were evaluated statistically using Kruskal-Wallis one-way/anova and Mann-Whitney U-tests. It was found that the bond strengths of SB + 3MVP, LB2 + CAP-X and VP + V to buccal dentine surfaces were significantly stronger (P 0.05). Vitremer was found the least successful adhesive material in terms of shear bond strength on both buccal and occluso-cervical dentine surfaces.

  11. Strength analysis of PGV-1000M steam generator support

    International Nuclear Information System (INIS)

    Dubik, Ya.R.; Ageev, S.M.; Orynyak, I.V.; Vasilchenko, B.M.

    2017-01-01

    The paper presents the design of PGV-1000M steam generator support. It is shown that the load in the rolling support is distributed extremely unevenly, which is associated with the compliance of the support construction. It is demonstrated that under working loads only several rollers are used, the stresses in which exceed the yield strength. This can be an additional loading factor to be considered in the analysis of welding No. 111 failure.

  12. Grip strength in mice with joint inflammation: A rheumatology function test sensitive to pain and analgesia.

    Science.gov (United States)

    Montilla-García, Ángeles; Tejada, Miguel Á; Perazzoli, Gloria; Entrena, José M; Portillo-Salido, Enrique; Fernández-Segura, Eduardo; Cañizares, Francisco J; Cobos, Enrique J

    2017-10-01

    Grip strength deficit is a measure of pain-induced functional disability in rheumatic disease. We tested whether this parameter and tactile allodynia, the standard pain measure in preclinical studies, show parallels in their response to analgesics and basic mechanisms. Mice with periarticular injections of complete Freund's adjuvant (CFA) in the ankles showed periarticular immune infiltration and synovial membrane alterations, together with pronounced grip strength deficits and tactile allodynia measured with von Frey hairs. However, inflammation-induced tactile allodynia lasted longer than grip strength alterations, and therefore did not drive the functional deficits. Oral administration of the opioid drugs oxycodone (1-8 mg/kg) and tramadol (10-80 mg/kg) induced a better recovery of grip strength than acetaminophen (40-320 mg/kg) or the nonsteroidal antiinflammatory drugs ibuprofen (10-80 mg/kg) or celecoxib (40-160 mg/kg); these results are consistent with their analgesic efficacy in humans. Functional impairment was generally a more sensitive indicator of drug-induced analgesia than tactile allodynia, as drug doses that attenuated grip strength deficits showed little or no effect on von Frey thresholds. Finally, ruthenium red (a nonselective TRP antagonist) or the in vivo ablation of TRPV1-expressing neurons with resiniferatoxin abolished tactile allodynia without altering grip strength deficits, indicating that the neurobiology of tactile allodynia and grip strength deficits differ. In conclusion, grip strength deficits are due to a distinct type of pain that reflects an important aspect of the human pain experience, and therefore merits further exploration in preclinical studies to improve the translation of new analgesics from bench to bedside. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Strength and fatigue testing of large size wind turbines rotors. Vol. II: Full size natural vibration and static strength test, a reference case

    Energy Technology Data Exchange (ETDEWEB)

    Arias, F.; Soria, E.

    1996-12-01

    This report shows the methods and procedures selected to define a strength test for large size wind turbine, anyway in particular it application on a 500 kW blade and it results obtained in the test carried out in july of 1995 in Asinel`s test plant (Madrid). Henceforth, this project is designed in an abbreviate form whit the acronym SFAT. (Author)

  14. Strength and fatigue testing of large size wind turbines rotors. Volume II. Full size natural vibration and static strength test, a reference case

    International Nuclear Information System (INIS)

    Arias, F.; Soria, E.

    1996-01-01

    This report shows the methods and procedures selected to define a strength test for large size wind turbine, anyway in particularly it application on a 500 kW blade and it results obtained in the test carried out in july of 1995 in Asinel test plant (Madrid). Henceforth, this project is designed in an abbreviate form whit the acronym SFAT. (Author)

  15. Strength function for the giant isovector monopole resonance

    International Nuclear Information System (INIS)

    MacDonald, W.M.; Birse, M.C.

    1984-01-01

    The theory of the strength function for giant resonances is extended to exhibit the explicit energy dependence of the width and shift functions for the giant isovector monopole. An integral sum rule on the width GAMMA/sub M/(E) relates its normalization to the second moment M 2 of the strength function and leads to a relation GAMMA/sub M/(E/sub M/)GAMMA/sub s//4 = M 2 between M 2 and the width at the maximum, which involves the width GAMMA/sub s/ of the distribution in energy of the spreading matrix elements. An estimate of GAMMA/sub M/(E/sub M/)approx. =8 MeV based on the absorptive part of the optical potential together with random-phase approximation calculations of M 2 leads to the result GAMMA/sub s//2approx. =2hω, supporting the intermediate coupling model of Lane, Thomas, and Wigner. Using the sum rule expressions of Lane and Mekjian to evaluate the Coulomb matrix element M/sub A/M between an isobaric analog state and its corresponding isovector monopole, we test this strength function for the isovector monopole by calculating the spreading widths for the ground state analogs of nuclei from 38 Cl to 208 Pb. The good agreement with the systematic dependence upon mass number and isospin resolves the long-standing discrepancy between the estimate GAMMA/sub M/(E/sub M/)approx.8--10 MeV and the value GAMMA/sub M/(E/sub A/)< or =2 MeV needed to account for the spreading widths of the isobaric analog state

  16. Effects of reclaimed asphalt pavement on indirect tensile strength test of foamed asphalt mix tested in dry condition

    International Nuclear Information System (INIS)

    Katman, Herda Yati; Norhisham, Shuhairy; Ismail, Norlela; Ibrahim, Mohd Rasdan; Matori, Mohd Yazip

    2013-01-01

    Indirect tensile strength (ITS) test was conducted to analyse strength of the foamed asphalt mixes incorporating reclaimed asphalt pavement. Samples were tested for ITS after cured in the oven at 40°C for 72 hours. This testing condition known as dry condition or unconditioned. Laboratory results show that reclaimed asphalt pavement (RAP) contents insignificantly affect the ITS results. ITS results significantly affected by foamed bitumen contents.

  17. Association with isokinetic ankle strength measurements and normal clinical muscle testing in sciatica patients.

    Science.gov (United States)

    Ustun, N; Erol, O; Ozcakar, L; Ceceli, E; Ciner, O Akar; Yorgancioglu, Z R

    2013-01-01

    Sensitive muscle strength tests are needed to measure muscle strength in the diagnosis and management of sciatica patients. The aim of this study was to assess the isokinetic muscle strength in sciatica patients' and control subjects' ankles that exhibited normal ankle muscle strength when measured clinically. Forty-six patients with L5 and/or S1 nerve compression, and whose age, sex, weight, and height matched 36 healthy volunteers, were recruited to the study. Heel-walking, toe-walking, and manual muscle testing were used to perform ankle dorsiflexion and plantar flexion strengths in clinical examination. Patients with normal ankle dorsiflexion and plantar flexion strengths assessed by manual muscle testing and heel-and toe-walking tests were included in the study. Bilateral isokinetic (concentric/concentric) ankle plantar-flexion-dorsiflexion measurements of the patients and controls were performed within the protocol of 30°/sec (5 repetitions). Peak torque and peak torque/body weight were obtained for each ankle motion of the involved limb at 30°/s speed. L5 and/or S1 nerve compression was evident in 46 patients (76 injured limbs). Mean disease duration was two years. The plantar flexion muscle strength of the patients was found to be lower than that of the controls (p=0.036). The dorsiflexion muscle strength of the patients was found to be the same as that of the controls (p=0.211). Isokinetic testing is superior to clinical muscle testing when evaluating ankle plantar flexion torque in sciatica patients. Therefore, isokinetic muscle testing may be helpful when deciding whether to place a patient into a focused rehabilitation program.

  18. Tinetti mobility test is related to muscle mass and strength in non-institutionalized elderly people.

    Science.gov (United States)

    Curcio, Francesco; Basile, Claudia; Liguori, Ilaria; Della-Morte, David; Gargiulo, Gaetano; Galizia, Gianluigi; Testa, Gianluca; Langellotto, Assunta; Cacciatore, Francesco; Bonaduce, Domenico; Abete, Pasquale

    2016-12-01

    Elderly people are characterized by a high prevalence of falls and sarcopenia. However, the relationship among Tinetti mobility test (TMT) score, a powerful tool to detect elderly people at risk of falls, and sarcopenia is still not thoroughly investigated. Thus, to determine the relationship between TMT score and muscle mass and strength, 337 elderly participants (mean age 77.1 ± 6.9 years) admitted to comprehensive geriatric assessment were enrolled. TMT score, muscle mass by bioimpedentiometer, and muscle strength by grip strength were evaluated. Muscle mass progressively decreased as TMT score decreased (from 15.3 ± 3.7 to 8.8 ± 1.8 kg/m 2 ; p for trend strength decreased progressively as Tinetti score decreased (from 34.7 ± 8.0 to 23.7 ± 8.7 kg; p for trend 0.001). Linear regression analysis demonstrated that TMT score is linearly related with muscle mass (y = 4.5x + 0.4, r = 0.61; p strength (y = 14.0x + 0.8, r = 0.53; p strength (r = 0.39, p = 0.046). The present study indicates that TMT score is significantly related to muscle mass and strength in non-institutionalized elderly participants. This evidence suggests that TMT score, together with evaluation of muscle mass and strength, may identify sarcopenic elderly participants at high risk of falls.

  19. Effects of core instability strength training on trunk muscle strength, spinal mobility, dynamic balance and functional mobility in older adults.

    Science.gov (United States)

    Granacher, Urs; Lacroix, Andre; Muehlbauer, Thomas; Roettger, Katrin; Gollhofer, Albert

    2013-01-01

    Age-related postural misalignment, balance deficits and strength/power losses are associated with impaired functional mobility and an increased risk of falling in seniors. Core instability strength training (CIT) involves exercises that are challenging for both trunk muscles and postural control and may thus have the potential to induce benefits in trunk muscle strength, spinal mobility and balance performance. The objective was to investigate the effects of CIT on measures of trunk muscle strength, spinal mobility, dynamic balance and functional mobility in seniors. Thirty-two older adults were randomly assigned to an intervention group (INT; n = 16, aged 70.8 ± 4.1 years) that conducted a 9-week progressive CIT or to a control group (n = 16, aged 70.2 ± 4.5 years). Maximal isometric strength of the trunk flexors/extensors/lateral flexors (right, left)/rotators (right, left) as well as of spinal mobility in the sagittal and the coronal plane was measured before and after the intervention program. Dynamic balance (i.e. walking 10 m on an optoelectric walkway, the Functional Reach test) and functional mobility (Timed Up and Go test) were additionally tested. Program compliance was excellent with participants of the INT group completing 92% of the training sessions. Significant group × test interactions were found for the maximal isometric strength of the trunk flexors (34%, p training-related improvements were found for spinal mobility in the sagittal (11%, p velocity (9%, p velocity (31%, p training regimen could be used as an adjunct or even alternative to traditional balance and/or resistance training. Copyright © 2012 S. Karger AG, Basel.

  20. Predicting bending strength of fire-retardant-treated plywood from screw-withdrawal tests

    Science.gov (United States)

    J. E. Winandy; P. K. Lebow; W. Nelson

    This report describes the development of a test method and predictive model to estimate the residual bending strength of fire-retardant-treated plywood roof sheathing from measurement of screw-withdrawal force. The preferred test methodology is described in detail. Models were developed to predict loss in mean and lower prediction bounds for plywood bending strength as...

  1. Seismic proving test of ultimate piping strength (current status of preliminary tests)

    International Nuclear Information System (INIS)

    Suzuki, K.; Namita, Y.; Abe, H.; Ichihashi, I.; Suzuki, K.; Ishiwata, M.; Fujiwaka, T.; Yokota, H.

    2001-01-01

    In 1998 Fiscal Year, the 6 year program of piping tests was initiated with the following objectives: i) to clarify the elasto-plastic response and ultimate strength of nuclear piping, ii) to ascertain the seismic safety margin of the current seismic design code for piping, and iii) to assess new allowable stress rules. In order to resolve extensive technical issues before proceeding on to the seismic proving test of a large-scale piping system, a series of preliminary tests of materials, piping components and simplified piping systems is intended. In this paper, the current status of the material tests and the piping component tests is reported. (author)

  2. Explosive strength training improves speed and agility in wheelchair basketball athletes

    Directory of Open Access Journals (Sweden)

    Tarik Ozmen

    2014-04-01

    Full Text Available INTRODUCTION: Wheelchair basketball is a paralympic sport characterized by intermittent high-intensity activities that require explosive strength and speed. OBJECTIVE: To investigate the effect of explosive strength training on speed and agility performance in wheelchair basketball players. METHODS: Ten male wheelchair basketball players (Mage=31±4 yrs were divided into two groups [i.e. explosive strength training (ES; control (CN] based on International Wheelchair Basketball Federation (IWBF classification scores. The ES group underwent 6-weeks of training, twice weekly, at 50% 1RM, 10-12 repetitions and 3-4 sets in addition to routine training. Effects of training were measured by the 20 m sprint test and Illinois agility test. RESULTS: The ES group, showed significantly higher increases in speed and agility performance (p ≤ .05. CONCLUSION: A short-duration (i.e. 6-week explosive strength training programme in wheelchair basketball athletes results in significant improvements in sprint and agility performance.

  3. The effect of proton correlations in the M1 scattering strengths of even calcium isotopes

    International Nuclear Information System (INIS)

    Chaves, L.; Poves, A.

    1986-01-01

    The proton correlations are evaluated in Ca isotopes using the wave functions obtained in an extended shell model calculation in the [1dsub(3/2), 1fsub(7/2), 1fsub(5/2)] valence space. The inclusion of 2p-2h correlations in M1 scattering strengths and magnetic moments improves the agrreement with the experimental data. The M1 strength in 40 Ca is correctly reproduced. (orig.)

  4. Enhancement of strength properties of hot rolled 10KHSND steel

    International Nuclear Information System (INIS)

    Nasibov, A.G.; Popova, L.V.; Pikulin, S.A.; Globa, N.I.

    1989-01-01

    To find out the reasons of low hot rolling yield for 10KhSND steel sheets in mechanical properties, titanium effect in the range of 0.008-0.03% concentrations is studied. It is established that the titanium content in a solid solution is conserved within 0.003-0.005%, the rest of titanium is bound to carbonitrides Ti(C, N). It is shown that alloys with 0.025-0.03% titanium content possess the increased values of ultimate and yield strength the necessary level of impact strength and good wealdability. The good steel yield, when the titanium content is sustained at the given level, increases from 40 to 85%

  5. Analysis of Tests Evaluating Sport Climbers’ Strength and Isometric Endurance

    Directory of Open Access Journals (Sweden)

    Ozimek Mariusz

    2016-12-01

    Full Text Available The present study was designed to determine which types of specific tests provide an effective evaluation of strength and endurance in highly trained competitive sport climbers. The research process consisted of three basic components: the measurement of selected somatic characteristics of the climbers, the assessment of their physical conditioning, and a search for correlations between the anthropometric and “conditioning” variables on the one hand, and climber’s performance on the other. The sample of subjects consisted of 14 experienced volunteer climbers capable of handling 7a- 8a+/b on-sight rock climbing grades. The strongest correlations (Spearman’s rank were found between climber’s competence and the relative results of the finger strength test (r = 0.7; much lower, but still statistically significant coefficients were found between the level of competence and the results of the muscle endurance tests (r = 0.53 – 0.57. Climbers aspiring to attain an elite level must have strong finger and forearm muscles, but most of all, they must be capable of releasing their potential during specific motor capability tests engaging these parts of the body. The forearm muscles of elite climbers must also be very resistant to fatigue. Since highly trained athletes vary only slightly in body mass, this variable does not have a major effect on their performance during strength and endurance tests.

  6. High-speed scanning ablation of dental hard tissues with a λ = 9.3 μm CO2 laser: adhesion, mechanical strength, heat accumulation, and peripheral thermal damage

    Science.gov (United States)

    Nguyen, Daniel; Chang, Kwang; Hedayatollahnajafi, Saba; Staninec, Michal; Chan, Kenneth; Lee, Robert; Fried, Daniel

    2011-07-01

    CO2 lasers can be operated at high laser pulse repetition rates for the rapid and precise removal of dental decay. Excessive heat accumulation and peripheral thermal damage is a concern when using high pulse repetition rates. Peripheral thermal damage can adversely impact the mechanical strength of the irradiated tissue, particularly for dentin, and reduce the adhesion characteristics of the modified surfaces. The interpulpal temperature rise was recorded using microthermocouples situated at the roof of the pulp chamber on teeth that were occlusally ablated using a rapidly-scanned CO2 laser operating at 9.3 μm with a pulse duration of 10 to 15 μs and repetition rate of 300 Hz over a 2 min time course. The adhesion strength of laser treated enamel and dentin surfaces was measured for various laser scanning parameters with and without post-ablation acid etching using the single-plane shear test. The mechanical strength of laser-ablated dentin surfaces were determined via the four-point bend test and compared to control samples prepared with 320 grit wet sand paper to simulate conventional preparations. Thermocouple measurements indicated that the temperature remained below ambient temperature if water-cooling was used. There was no discoloration of either dentin or enamel laser treated surfaces, the surfaces were uniformly ablated, and there were no cracks visible. Four-point bend tests yielded mean mechanical strengths of 18.2 N (s.d. = 4.6) for ablated dentin and 18.1 N (s.d. = 2.7) for control (p > 0.05). Shear tests yielded mean bond strengths approaching 30 MPa for both enamel and dentin under certain irradiation conditions. These values were slightly lower than nonirradiated acid-etched control samples. Additional studies are needed to determine if the slightly lower bond strength than the acid-etched control samples is clinically significant. These measurements demonstrate that enamel and dentin surfaces can be rapidly ablated by CO2 lasers with minimal

  7. Effects of In-Season Explosive Strength Training on Maximal Leg Strength, Jumping, Sprinting, and Intermittent Aerobic Performance in Male Handball Athletes.

    Science.gov (United States)

    Hermassi, Souhail; Chelly, Mohamed Souhaiel; Fieseler, Georg; Bartels, Thomas; Schulze, Stephan; Delank, Karl-Stefan; Shephard, Roy J; Schwesig, René

    2017-09-01

    Background  Team handball is an intense ball sport with specific requirements on technical skills, tactical understanding, and physical performance. The ability of handball players to develop explosive efforts (e. g. sprinting, jumping, changing direction) is crucial to success. Objective  The purpose of this pilot study was to examine the effects of an in-season high-intensity strength training program on the physical performance of elite handball players. Materials and methods  Twenty-two handball players (a single national-level Tunisian team) were randomly assigned to a control group (CG; n = 10) or a training group (TG; n = 12). At the beginning of the pilot study, all subjects performed a battery of motor tests: one repetition maximum (1-RM) half-squat test, a repeated sprint test [6 × (2 × 15 m) shuttle sprints], squat jumps, counter movement jumps (CMJ), and the Yo-Yo intermittent recovery test level 1. The TG additionally performed a maximal leg strength program twice a week for 10 weeks immediately before engaging in regular handball training. Each strength training session included half-squat exercises to strengthen the lower limbs (80 - 95 % of 1-RM, 1 - 3 repetitions, 3 - 6 sets, 3 - 4 min rest between sets). The control group underwent no additional strength training. The motor test battery was repeated at the end of the study interventions. Results  In the TG, 3 parameters (maximal strength of lower limb: η² = 0.74; CMJ: η² = 0.70, and RSA best time: η² = 0.25) showed significant improvements, with large effect sizes (e. g. CMJ: d = 3.77). A reduction in performance for these same 3 parameters was observed in the CG (d = -0.24). Conclusions  The results support our hypothesis that additional strength training twice a week enhances the maximal strength of the lower limbs and jumping or repeated sprinting performance. There was no evidence of shuttle sprints ahead of regular

  8. A Field Test for Upper Body Strength and Endurance.

    Science.gov (United States)

    Nelson, Jack K.; And Others

    1991-01-01

    Researchers studied the reliability of the modified push-up test in measuring upper body strength and endurance in elementary through college students. It also examined the accuracy of partner scoring. The test proved much easier to administer than the regular floor push-up. It was valid and reliable for all students and suitable for partner…

  9. Performance on Functional Strength Measurement and Muscle Power Sprint Test confirm poor anaerobic capacity in children with Developmental Coordination Disorder.

    Science.gov (United States)

    Aertssen, Wendy F M; Ferguson, Gillian D; Smits-Engelsman, Bouwien C M

    2016-12-01

    There is little and conflicting information about anaerobic performance and functional strength in children with Developmental Coordination Disorder (DCD). To investigate anaerobic capacity and functional strength in children with a clinical diagnosis of DCD (clin-DCD) and if differences were larger in older (age 7-10 years) compared to younger children (age 4-6 years). Furthermore to determine the percentage of children with clin-DCD that scored Strength Measurement. A clin-DCD group (36 boys, 11 girls, mean age: 7y 1mo, SD=2y 1mo) and a typically developing group (TD) (57 boys, 53 girls, mean age: 7y 5mo, SD=1y 10mo) were compared on Muscle Power Sprint Test (MPST) and Functional Strength Measurement (FSM). Children with clin-DCD performed poorer on the MPST and FSM, especially on the muscle endurance items of the FSM. The differences were larger in the older children compared to the younger on the cluster muscle endurance and the FSM total score. Over 50% of clin-DCD group scored tested on items requiring fast repetitive movements. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Design and test of the RHIC CMD10 abort kicker

    International Nuclear Information System (INIS)

    Hahn, H.; Blaskiewicz, M.; Drees, A.; Fischer, W.; Mi, J.; Meng, W.; Montag, C.; Pai, C.; Sandberg, J.; Tsoupas, N.; Tuozzolo, J. E.; Zhang, W.

    2015-01-01

    In recent RHIC operational runs, planned and unplanned pre-fire triggered beam aborts have been observed that resulted in quenches of SC main ring magnets, indicating a weakened magnet kick strength due to beam-induced ferrite heating. An improvement program was initiated to reduce the longitudinal coupling impedance with changes to the ferrite material and the eddy-current strip geometry. Results of the impedance measurements and of magnet heating tests with CMD10 ferrite up to 190°C are reported. All 10 abort kickers in the tunnel have been modified and were provided with a cooling system for the RUN 15.

  11. Relationship between thin-film bond strength as measured by a scratch test, and indentation hardness for bonding agents.

    Science.gov (United States)

    Kusakabe, Shusuke; Rawls, H Ralph; Hotta, Masato

    2016-03-01

    To evaluate thin-film bond strength between a bonding agent and human dentin, using a scratch test, and the characteristics and accuracy of measurement. One-step bonding agents (BeautiBond; Bond Force; Adper Easy Bond; Clearfil tri-S Bond) and two-step bonding agents (Cleafil SE Bond; FL-Bond II) were investigated in this study. Flat dentin surfaces were prepared for extracted human molars. The dentin surfaces were ground and bonding agents were applied and light cured. The thin-film bond strength test of the specimens was evaluated by the critical load at which the coated bonding agent failed and dentin appeared. The scratch mark sections were then observed under a scanning electron microscope. Indentation hardness was evaluated by the variation in depth under an applied load of 10gf. Data were compared by one-way ANOVA with the Scheffé's post hoc multiple comparison test (pstrength and indentation hardness were analyzed using analysis of correlation and covariance. The thin-film bond strength of two-step bonding agents were found to be significantly higher than that of one-step bonding agents with small standard deviations. Scratch marks consistently showed adhesive failure in the vicinity of the bonding agent/dentin interface. The indentation hardness showed a trend that two-step bonding agents have greater hardness than one-step bonding agents. A moderately significant correlation (r(2)=0.31) was found between thin-film bond strength and indentation hardness. Thin-film bond strength test is a valid and reliable means of evaluating bond strength in the vicinity of the adhesive interface and is more accurate than other methods currently in use. Further, the thin-film bond strength is influenced by the hardness of the cued bonding agent. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Long-term bond strength of adhesive systems applied to etched and deproteinized dentin

    Directory of Open Access Journals (Sweden)

    Ninoshka Uceda-Gómez

    2007-12-01

    Full Text Available The aim of this study was to evaluate the early and 12-month bond strength of two adhesive systems (Single Bond-SB and One Step-OS applied to demineralized dentin (WH and demineralized/NaOCl-treated dentin (H. Twenty flat dentin surfaces were exposed, etched, rinsed and slightly dried. For the H groups, a solution of 10% NaOCl was applied for 60 s, rinsed (15 s and slightly dried. The adhesives were applied according to the manufacturer's instructions and composite resin crowns were incrementally constructed. After 24 h (water-37ºC, the specimens was sectioned in order to obtain resin-dentin sticks (0.8 mm². The specimens were tested in microtensile (0.5 mm/min immediately (IM or after 12 months of water storage (12M. The data (MPa were subjected to ANOVA and Tukey's test (a=0.05. Only the main factors adhesive and time were significant (p=0.004 and p=0.003, respectively. SB (42.3±9.1 showed higher bond strengths than OS (33.6±11.6. The mean bond strength for IM-group (42.5±8.7 was statistically superior to 12M (33.3±11.8. The use of 10% NaOCl, after acid etching, did not improve the immediate and the long-term resin-dentin bond strength.

  13. Can low-fusing glass application affect the marginal misfit and bond strength of Y-TZP crowns?

    Science.gov (United States)

    Antunes, Monize Carelli Felipe; Miranda, Jean Soares; Carvalho, Ronaldo Luís Almeida de; Carvalho, Rodrigo Furtado de; Kimpara, Estevão Tomomitsu; Assunção E Souza, Rodrigo Othávio de; Leite, Fabíola Pessôa Pereira

    2018-01-01

    To evaluate the effect of different surface treatments on the marginal misfit and retentive strength between Y-TZP crowns and an epoxy resin. Forty (40) epoxy resin (G10) abutments (height: 5mm, conicity: 60, finish line: large chamfer) with equal dimensions were milled and included in polyurethane to simulate the periodontal ligament. Next, 40 Y-TZP crowns (thickness: 1mm) were milled (Cerec in Lab) and randomly divided into four groups (n=10) according to the surface treatment: GS(glaze spray), GP(glaze powder/liquid), P(zirconia primer) and RS(tribochemical silica coating). The conditioned surfaces were cemented with dual self-adhesive cement, light cured and submitted to thermomechanical cycling (2x106, 100N, 4Hz, 5°/55°C). Marginal misfit was analyzed by a stereomicroscope and SEM. Retentive strength test was performed (1mm/min) until crown debonding. Glaze layer thickness was also performed to GS and GP groups. Marginal misfit data were analyzed by Kruskal Wallis and Dunn tests; one-way ANOVA and Tukey (5%) analyzed the tensile strength data. The marginal misfit of the GS (48.6±19.9μm) and GP (65.4±42.5μm) were statistically lower than the RS (96±62.9μm) and P (156±113.3μm) (p=0.001). The retentive strength of the GP (470.5±104.1N) and GS (416.8±170.2N) were similar to the P (342.1±109.7N), but statistically higher than those of the RS (208.9±110N). The GS and GP glaze layer was 11.64μm and 9.73μm respectively. Thus, glaze application promoted lower marginal discrepancy and higher retentive strength values than conventional techniques.

  14. Tensile strength of concrete under static and intermediate strain rates: Correlated results from different testing methods

    International Nuclear Information System (INIS)

    Wu Shengxing; Chen Xudong; Zhou Jikai

    2012-01-01

    Highlights: ► Tensile strength of concrete increases with increase in strain rate. ► Strain rate sensitivity of tensile strength of concrete depends on test method. ► High stressed volume method can correlate results from various test methods. - Abstract: This paper presents a comparative experiment and analysis of three different methods (direct tension, splitting tension and four-point loading flexural tests) for determination of the tensile strength of concrete under low and intermediate strain rates. In addition, the objective of this investigation is to analyze the suitability of the high stressed volume approach and Weibull effective volume method to the correlation of the results of different tensile tests of concrete. The test results show that the strain rate sensitivity of tensile strength depends on the type of test, splitting tensile strength of concrete is more sensitive to an increase in the strain rate than flexural and direct tensile strength. The high stressed volume method could be used to obtain a tensile strength value of concrete, free from the influence of the characteristics of tests and specimens. However, the Weibull effective volume method is an inadequate method for describing failure of concrete specimens determined by different testing methods.

  15. A cluster randomized controlled trial testing the effectiveness of Houvast: A strengths-based intervention for homeless young adults

    NARCIS (Netherlands)

    Krabbenborg, M.A.M.; Boersma, S.N.; Veld, W.M. van der; Hulst, B. van; Vollebergh, W.A.M.; Wolf, J.R.L.M.

    2017-01-01

    Objective: To test the effectiveness of Houvast: a strengths-based intervention for homeless young adults. Method: A cluster randomized controlled trial was conducted with 10 Dutch shelter facilities randomly allocated to an intervention and a control group. Homeless young adults were interviewed

  16. Design and Evaluation of a Wireless Sensor Network Based Aircraft Strength Testing System

    Science.gov (United States)

    Wu, Jian; Yuan, Shenfang; Zhou, Genyuan; Ji, Sai; Wang, Zilong; Wang, Yang

    2009-01-01

    The verification of aerospace structures, including full-scale fatigue and static test programs, is essential for structure strength design and evaluation. However, the current overall ground strength testing systems employ a large number of wires for communication among sensors and data acquisition facilities. The centralized data processing makes test programs lack efficiency and intelligence. Wireless sensor network (WSN) technology might be expected to address the limitations of cable-based aeronautical ground testing systems. This paper presents a wireless sensor network based aircraft strength testing (AST) system design and its evaluation on a real aircraft specimen. In this paper, a miniature, high-precision, and shock-proof wireless sensor node is designed for multi-channel strain gauge signal conditioning and monitoring. A cluster-star network topology protocol and application layer interface are designed in detail. To verify the functionality of the designed wireless sensor network for strength testing capability, a multi-point WSN based AST system is developed for static testing of a real aircraft undercarriage. Based on the designed wireless sensor nodes, the wireless sensor network is deployed to gather, process, and transmit strain gauge signals and monitor results under different static test loads. This paper shows the efficiency of the wireless sensor network based AST system, compared to a conventional AST system. PMID:22408521

  17. Design and evaluation of a wireless sensor network based aircraft strength testing system.

    Science.gov (United States)

    Wu, Jian; Yuan, Shenfang; Zhou, Genyuan; Ji, Sai; Wang, Zilong; Wang, Yang

    2009-01-01

    The verification of aerospace structures, including full-scale fatigue and static test programs, is essential for structure strength design and evaluation. However, the current overall ground strength testing systems employ a large number of wires for communication among sensors and data acquisition facilities. The centralized data processing makes test programs lack efficiency and intelligence. Wireless sensor network (WSN) technology might be expected to address the limitations of cable-based aeronautical ground testing systems. This paper presents a wireless sensor network based aircraft strength testing (AST) system design and its evaluation on a real aircraft specimen. In this paper, a miniature, high-precision, and shock-proof wireless sensor node is designed for multi-channel strain gauge signal conditioning and monitoring. A cluster-star network topology protocol and application layer interface are designed in detail. To verify the functionality of the designed wireless sensor network for strength testing capability, a multi-point WSN based AST system is developed for static testing of a real aircraft undercarriage. Based on the designed wireless sensor nodes, the wireless sensor network is deployed to gather, process, and transmit strain gauge signals and monitor results under different static test loads. This paper shows the efficiency of the wireless sensor network based AST system, compared to a conventional AST system.

  18. Responsiveness of the Countermovement Jump and Handgrip Strength to an Incremental Running Test in Endurance Athletes: Influence of Sex.

    Science.gov (United States)

    García-Pinillos, Felipe; Delgado-Floody, Pedro; Martínez-Salazar, Cristian; Latorre-Román, Pedro Á

    2018-03-01

    The present study analyzed the acute effects of an incremental running test on countermovement jump (CMJ) and handgrip strength performance in endurance athletes, considering the effect of post-exercise recovery time and sex. Thirty-three recreationally trained long-distance runners, 20 men and 13 women, participated voluntarily in this study. The participants performed the Léger test, moreover, the CMJ and handgrip strength tests were carried out before and after the running test and during different stages of recovery (at the 1st min of recovery (posttest1), 5th min of recovery (posttest2), and 10th min of recovery (posttest3)). Two-way analysis of variance revealed a significant improvement in the CMJ (pre-posttest1, p = 0.001) and handgrip strength (pre-posttest2, p = 0.017) during recovery time. The Pearson's Chi-2 test showed no significant relationship ( p ≥ 0.05) between sex and post-activation potentiation (PAP). A linear regression analysis pointed to heart rate recovery as a predictive factor of CMJ improvement (PAP). In conclusion, despite significant fatigue reached during the Léger test, the long-distance runners did not experience an impaired CMJ and handgrip strength performance, either men or women, achieving an improvement (PAP) in posttest conditions. The results obtained showed no significant relationship between sex and PAP. Moreover, significant effect of recovery after running at high intensity on CMJ performance and handgrip strength was found. Finally, the data suggest that PAP condition can be predicted by heart rate recovery in endurance runners.

  19. Conductivity ageing studies on 1M10ScSZ (M4+=Ce, Hf)

    DEFF Research Database (Denmark)

    Omar, Shobit; Bin Najib, Waqas; Bonanos, Nikolaos

    2011-01-01

    The long-term conductivity stability is tested on zirconia based electrolyte materials for solid oxide fuel cell applications. The ageing studies have been performed on the samples of ZrO2 co-doped with 10mol% of Sc2O3 and 1mol% MO2, where M = Ce or Hf (denoted respectively 1Ce10ScSZ and 1Hf10Sc......SZ) in oxidising and reducing atmospheres, at 600°C for 3000h. At 600°C, these compositions show initial conductivity of around 9–12mS∙cm−1 in air. After 3000h of ageing, no phase transitions are observed in any of the samples. For the first 1000h, the degradation rate is higher than in the subsequent 2000h......; thereafter, conductivity degrades linearly with time for all samples. In air, the loss in the conductivity is lower than in reducing conditions. The 1Ce10ScSZ shows the highest degradation rate of 3.8%/1000h in wet H2/N2 after the first 1000h of ageing. A colour change of the 1Ce10ScSZ sample from white...

  20. Evaluation of microtensile and tensile bond strength tests ...

    African Journals Online (AJOL)

    Objectives: The aim of the present study was to compare two different bond strength test methods (tensile and microtensile) in investing the influence of erbium, chromium: yttrium‑scandium‑gallium‑garnet (Er, Cr: YSGG) laser pulse frequency on resin‑enamel bonding. Materials and Methods: One‑hundred and twenty‑five ...

  1. Greater Strength Gains after Training with Accentuated Eccentric than Traditional Isoinertial Loads in Already Strength-Trained Men

    Science.gov (United States)

    Walker, Simon; Blazevich, Anthony J.; Haff, G. Gregory; Tufano, James J.; Newton, Robert U.; Häkkinen, Keijo

    2016-01-01

    As training experience increases it becomes more challenging to induce further neuromuscular adaptation. Consequently, strength trainers seek alternative training methods in order to further increase strength and muscle mass. One method is to utilize accentuated eccentric loading, which applies a greater external load during the eccentric phase of the lift as compared to the concentric phase. Based upon this practice, the purpose of this study was to determine the effects of 10 weeks of accentuated eccentric loading vs. traditional isoinertial resistance training in strength-trained men. Young (22 ± 3 years, 177 ± 6 cm, 76 ± 10 kg, n = 28) strength-trained men (2.6 ± 2.2 years experience) were allocated to concentric-eccentric resistance training in the form of accentuated eccentric load (eccentric load = concentric load + 40%) or traditional resistance training, while the control group continued their normal unsupervised training program. Both intervention groups performed three sets of 6-RM (session 1) and three sets of 10-RM (session 2) bilateral leg press and unilateral knee extension exercises per week. Maximum force production was measured by unilateral isometric (110° knee angle) and isokinetic (concentric and eccentric 30°.s−1) knee extension tests, and work capacity was measured by a knee extension repetition-to-failure test. Muscle mass was assessed using panoramic ultrasonography and dual-energy x-ray absorptiometry. Surface electromyogram amplitude normalized to maximum M-wave and the twitch interpolation technique were used to examine maximal muscle activation. After training, maximum isometric torque increased significantly more in the accentuated eccentric load group than control (18 ± 10 vs. 1 ± 5%, p < 0.01), which was accompanied by an increase in voluntary activation (3.5 ± 5%, p < 0.05). Isokinetic eccentric torque increased significantly after accentuated eccentric load training only (10 ± 9%, p < 0.05), whereas concentric torque

  2. Strength-ductility relationships in intermediate purity hot-pressed beryllium

    International Nuclear Information System (INIS)

    Stonehouse, A.J.; Bielawski, C.A.; Paine, R.M.

    1977-01-01

    The strength of vacuum hot-pressed, intermediate purity beryllium may be substantially increased without sacrifice of the strain capacity of the present grade (S-65) through decrease in the average grain size. Tensile strength of 517 MPa, 0.2% offset yield strength of 414 MPa with minimum 3% tensile elongation in all test directions could be commercially achieved. The tangent modulus of such material is quite attractive and suffers only about 10% degradation from room temperature to 260 0 C. The tangent modulus is dramatically enhanced by the presence of a yield point. The ductility of the materials studied did not appear to be affected by the BeO content across the range of 0.5 to 2.0% using nominal -44 to -15 μm powder particle sizes. All fine-grained pressings exhibited yield points in the as-pressed condition. Either full-density or sub-density hot-pressed billets given a hot isostatic pressing treatment without the use of cans showed only slight yield points after the HIP treatment with essentially the same strength and ductility factors as in the pressed condition. A plot of grain size vs yield strength in the as-pressed condition projects to an intercept with the fracture strength line at about 3 μm grain size. A similar plot after the HIP treatment shows a yield strength line parallel to the fracture strength line with no projected intercept predicting a completely brittle material. (author)

  3. Evaluating resin-enamel bonds by microshear and microtensile bond strength tests: effects of composite resin

    Directory of Open Access Journals (Sweden)

    Andrea Mello de Andrade

    2010-12-01

    Full Text Available OBJECTIVES: The aims of this study were to evaluate the effect of resin composite (Filtek Z250 and Filtek Flow Z350 and adhesive system [(Solobond Plus, Futurabond NR (VOCO and Adper Single Bond (3M ESPE] on the microtensile (μTBS and microshear bond strength (μSBS tests on enamel, and to correlate the bond strength means between them. MATERIAL AND METHODS: Thirty-six extracted human molars were sectioned to obtain two tooth halves: one for μTBS and the other one for μSBS. Adhesive systems and resin composites were applied to the enamel ground surfaces and light-cured. After storage (37(0C/24 h specimens were stressed (0.5 mm/min. Fracture modes were analyzed under scanning electron microscopy. The data were analyzed using two-way ANOVA and Tukey's test (α=0.05. RESULTS: The correlation between tests was estimated with Pearson's product-moment correlation statistics (α =0.05. For both tests only the main factor resin composite was statistically significant (p<0.05. The correlation test detected a positive (r=0.91 and significant (p=0.01 correlation between the tests. CONCLUSIONS: The results were more influenced by the resin type than by the adhesives. Both microbond tests seem to be positive and linearly correlated and can therefore lead to similar conclusions.

  4. Standard test method for splitting tensile strength for brittle nuclear waste forms

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1989-01-01

    1.1 This test method is used to measure the static splitting tensile strength of cylindrical specimens of brittle nuclear waste forms. It provides splitting tensile-strength data that can be used to compare the strength of waste forms when tests are done on one size of specimen. 1.2 The test method is applicable to glass, ceramic, and concrete waste forms that are sufficiently homogeneous (Note 1) but not to coated-particle, metal-matrix, bituminous, or plastic waste forms, or concretes with large-scale heterogeneities. Cementitious waste forms with heterogeneities >1 to 2 mm and 5 mm can be tested using this procedure provided the specimen size is increased from the reference size of 12.7 mm diameter by 6 mm length, to 51 mm diameter by 100 mm length, as recommended in Test Method C 496 and Practice C 192. Note 1—Generally, the specimen structural or microstructural heterogeneities must be less than about one-tenth the diameter of the specimen. 1.3 This test method can be used as a quality control chec...

  5. Effects of Seated Postural Stability and Trunk and Upper Extremity Strength on Performance during Manual Wheelchair Propulsion Tests in Individuals with Spinal Cord Injury: An Exploratory Study.

    Science.gov (United States)

    Gagnon, Dany H; Roy, Audrey; Gabison, Sharon; Duclos, Cyril; Verrier, Molly C; Nadeau, Sylvie

    2016-01-01

    Objectives. To quantify the association between performance-based manual wheelchair propulsion tests (20 m propulsion test, slalom test, and 6 min propulsion test), trunk and upper extremity (U/E) strength, and seated reaching capability and to establish which ones of these variables best predict performance at these tests. Methods. 15 individuals with a spinal cord injury (SCI) performed the three wheelchair propulsion tests prior to discharge from inpatient SCI rehabilitation. Trunk and U/E strength and seated reaching capability with unilateral hand support were also measured. Bivariate correlation and multiple linear regression analyses allowed determining the best determinants and predictors, respectively. Results. The performance at the three tests was moderately or strongly correlated with anterior and lateral flexion trunk strength, anterior seated reaching distance, and the shoulder, elbow, and handgrip strength measures. Shoulder adductor strength-weakest side explained 53% of the variance on the 20-meter propulsion test-maximum velocity. Shoulder adductor strength-strongest side and forward seated reaching distance explained 71% of the variance on the slalom test. Handgrip strength explained 52% of the variance on the 6-minute propulsion test. Conclusion. Performance at the manual wheelchair propulsion tests is explained by a combination of factors that should be considered in rehabilitation.

  6. Shear bond strength of resin composite bonded with two adhesives: Influence of Er: YAG laser irradiation distance

    Science.gov (United States)

    Shirani, Farzaneh; Birang, Reza; Malekipour, Mohammad Reza; Hourmehr, Zahra; Kazemi, Shantia

    2014-01-01

    Background: Dental surfaces prepared with different Er:YAG laser distance may have different characteristics compared with those prepared with conventional instruments. The aim of this study was to investigate the effect of Er:YAG laser irradiation distance from enamel and dentin surfaces on the shear bond strength of composite with self-etch and etch and rinse bonding systems compared with conventional preparation method. Materials and Methods: Two hundred caries-free human third molars were randomly divided into twenty groups (n = 10). Ten groups were designated for enamel surface (E1-E10) and ten for dentin surface (D1-D10). Er: YAG laser (2940 nm) was used on the E1-E8 (240 mJ, 25 Hz) and D1-D8 (140 mJ, 30 Hz) groups at four different distances of 0.5 (standard), 2, 4 and 11 mm. Control groups (E9, E10, D9 and D10) were ground with medium grit diamond bur. The enamel and dentin specimens were divided into two subgroups that were bonded with either Single Bond or Clearfil SE Bond. Resin composite (Z100) was dispensed on prepared dentin and enamel. The shear bond strengths were tested using a universal testing machine. Data were analyzed by SPSS12 statistical software using three way analysis of variance, Tukey and independent t-test. P enamel and dentin substrates (P enamel surfaces (in both bonding agent subgroups) and on dentin surfaces (in the Single Bond subgroup). Conclusion: Laser irradiation decreases shear bond strength. Irradiation distance affects shear bond strength and increasing the distance would decrease the negative effects of laser irradiation. PMID:25540665

  7. Quadriceps Strength in Patients With Isolated Cartilage Defects of the Knee: Results of Isokinetic Strength Measurements and Their Correlation With Clinical and Functional Results.

    Science.gov (United States)

    Hirschmüller, Anja; Andres, Tasja; Schoch, Wolfgang; Baur, Heiner; Konstantinidis, Lukas; Südkamp, Norbert P; Niemeyer, Philipp

    2017-05-01

    Recent studies have found a significant deficit of maximum quadriceps strength after autologous chondrocyte implantation (ACI) of the knee. However, it is unclear whether muscular strength deficits in patients with cartilage damage exist prior to operative treatment. To isokinetically test maximum quadriceps muscle strength and quantify the impact of possible strength deficits on functional and clinical test results. Cross-sectional study; Level of evidence, 3. To identify clinically relevant muscular strength deficits, 24 patients (5 females, 19 males; mean age, 34.5 years; body mass index, 25.9 kg/m 2 ) with isolated cartilage defects (mean onset, 5.05 years; SD, 7.8 years) in the knee joint underwent isokinetic strength measurements. Maximal quadriceps strength was recorded in 3 different testing modes: pure concentric contraction (flexors and extensors alternating work; con1), concentric-eccentric (only the extensors work concentrically and eccentrically; con2), and eccentric contraction in the alternating mode (ecc). Results were compared for functional performance (single-leg hop test), pain scales (visual analog scale [VAS], numeric rating scale [NRS]), self-reported questionnaires (International Knee Documentation Committee [IKDC], Knee Injury and Osteoarthritis Outcome Scale [KOOS]), and defect size (cm 2 ). Compared with the uninjured leg, significantly lower quadriceps strength was detected in the injured leg in all isokinetic working modes (con1 difference, 27.76 N·m [SD 17.47; P = .003]; con2 difference, 21.45 N·m [SD, 18.45; P =.025]; ecc difference, 29.48 N·m [SD, 21.51; P = .001]), with the largest deficits found for eccentric muscle performance. Moderate negative correlations were observed for the subjective pain scales NRS and VAS. The results of the IKDC and KOOS questionnaires showed low, nonsignificant correlations with findings in the isokinetic measurement. Moreover, defect sizes (mean, 3.13 cm 2 ) were of no importance regarding the

  8. THE EFFECTS OF ISOKINETIC KNEE STRENGTH ON THE PROMPTNESS OF SOCCER PLAYERS

    OpenAIRE

    Ali Kerim Yilmaz; Menderes Kabadayi; Muhammet Hakan Mayda; Murşit Ceyhun Birinci; Mustafa Özdal

    2017-01-01

    The purpose of this study is to examine the effects of isokinetic knee strength on promptness. 15 soccer players with an average age of 22,80±2,14 years and 15 controls with an average age of 21,60±1,40 years participated in the study. Body composition, isokinetic knee strength measurement at angular speeds of 60o, 180o, 240o and 10 m sprint test were conducted respectively in the study. General warm-up procedure was carried out on the groups before measurements. In statistical analyses, Shap...

  9. Push-off tests and strength evaluation of joints combining shrink fitting with bonding

    Science.gov (United States)

    Yoneno, Masahiro; Sawa, Toshiyuki; Shimotakahara, Ken; Motegi, Yoichi

    1997-03-01

    Shrink fitted joints have been used in mechanical structures. Recently, joints combining shrink fitting with anaerobic adhesives bonded between the shrink fitted surfaces have been appeared in order to increase the joint strength. In this paper, push-off test was carried out on strength of joints combining shrink fitting with bonding by material testing machine. In addition, the push-off strength of shrink fitting joints without an anaerobic adhesive was also measured. In the experiments, the effects of the shrinking allowance and the outer diameter of the rings on the joint strength are examined. The interface stress distribution in bonded shrink fitted joints subjected to a push-off load is analyzed using axisymmetrical theory of elasticity as a four-body contact problem. Using the interface stress distribution, a method for estimating joint strength is proposed. The experimental results are in a fairly good agreement with the numerical results. It is found that the strength of combination joints is greater than that of shrink fitted joints.

  10. Shear bond strength after dentin bleaching with 10% carbamide peroxide agents

    OpenAIRE

    Basting, Roberta Tarkany; Freitas, Patrícia Moreira de; Pimenta, Luiz André Freire; Serra, Mônica Campos

    2004-01-01

    This in vitro study evaluated the shear bond strength (SBS) of dentin treated with two 10% carbamide peroxide bleaching agents 15 days after bleaching and storage in artificial saliva. Dentin fragments were randomly divided into 3 groups (n = 20) for the treatment with the two different bleaching agents (Rembrandt 10% or Opalescence 10%) or with a placebo agent, applied to the tooth surface for 8 hours a day. During the remaining time, the specimens were stored in artificial saliva. After 42 ...

  11. Fracture strength of aluminium alloys under rapid loading conditions

    International Nuclear Information System (INIS)

    Joshi, K.D.; Rav, Amit S.; Sur, Amit; Kaushik, T.C.; Gupta, Satish C.

    2016-04-01

    Spall fracture strength and dynamic yield strength of aluminium alloys have been measured at high strain rates generated in plate impact experiments carried out at different impact velocities ranging from 174 m/s to 560 m/s using single stage gas gun facility. In each experiment, the free surface velocity history of the sample plate of aluminium alloy has been derived from time resolved Doppler shift measured employing indigenously developed velocity interferometer system for any reflector (VISAR). The free surface velocity history so determined has been used to evaluate the spall fracture strength and dynamic yield strength of the target material. The two kinds of alloys of aluminium namely Al2014-T4 and Al2024-T4 have been investigated in these experiments. In Al2014-T4 target plates, the spall strength determined from free surface velocity history recorded for impact velocities of 179 m/s, 307 m/s, 398 m/s and 495m/s is 0.90 GPa, 0.96 GPa, 1.0 GPa and 1.1 GPa, respectively. The average strain rates just ahead of spall pulse have been found to vary from ∼ 1.1×10 4 /s to 2.4×10 4 /s. The dynamic yield strength derived from the measured Hugoniot elastic limit ranges from 0.36 GPa to 0.40 GPa. The spall strength for Al2024-T4 samples has been determined to be 1.11 GPa, 1.18 GPa and 1.42 GPa, at impact velocities of 174 m/s, 377 m/s and 560 m/s, respectively. The corresponding average strain rates range from 1.9×104/s to 2.5×104/s. The dynamic yield strength of Al2024-T4 at these impact velocities has been found to vary from 0.37 GPa to 0.43 GPa. The measured spall strengths in all these experiments are higher than the quasi-static value of 0.511 GPa for Al2014-T4 and 0.470 GPa for Al2024. Similarly, the dynamic yield strengths are also larger than the quasi-static value of 0.355 GPa for Al2014-T4 and 0.360 GPa for Al2024-T4. These experimental studies suggest that at high strain rates, both the alloys of aluminium offer higher resistance against the tensile

  12. Correlation of single-breath count test and neck flexor muscle strength with spirometry in myasthenia gravis.

    Science.gov (United States)

    Elsheikh, Bakri; Arnold, W David; Gharibshahi, Shahram; Reynolds, Jerold; Freimer, Miriam; Kissel, John T

    2016-01-01

    Although formal spirometry is the gold standard for monitoring respiratory function in patients with myasthenia gravis (MG), such testing is often delayed or unavailable. There is a need for a simple bedside test that can accurately measure respiratory function. We conducted a prospective, cross-sectional, single-blind study in adults with acetylcholine receptor antibody positive MG. Participants performed the single breath count test (SBCT) and underwent manual muscle strength testing, and a respiratory therapist performed spirometry blinded to SBCT and strength results. Thirty-one patients, aged 57 ± 19 years participated. SBCT showed significant correlations with forced vital capacity (FVC), negative inspiratory force, and neck flexor strength (P strength (P = 0.02) but no correlation with shoulder abductor strength. These data suggest that the SBCT and neck flexor strength testing are valuable tools for bedside assessment of respiratory function in MG patients. © 2015 Wiley Periodicals, Inc.

  13. Beam Test for Evaluating Applicabillity of High - Strength Reinforcement in Structure of Nuclear Facility

    International Nuclear Information System (INIS)

    Yim, Sangjun; Lee, Byungsoo; Bang, Changjoon

    2014-01-01

    The high-strength rebar which has high yield strength can reduce the amount of rebar in concrete and widen its spacing so that it has better workability and higher economic benefits for the structure. However, the maximum yield strength of rebar is limited to 420MPa in the design criteria for structure of nuclear facility in Korea and USA. Korea Hydro and Nuclear Power is progressing research to revise the limitation in the yield strength of rebar, which is suggested in the criteria of KEPIC and ACI, in order to apply 550 MPa high-strength rebar for the construction of a nuclear facility. This study is to review the applicability of high strength rebar in structure of a nuclear facility through a model beam test. After reviewing the shear capacity and reinforcement yield to assess the applicability of high-strength reinforcement in the structure of a nuclear facility, we make the following conclusions. When using high shear reinforcement with wider spacing, it has a similar shear capacity to normal reinforcement with narrower spacing. This means better workability and economic benefits can be achieved by widening the rebar spacing without brittle fracture in the elements. For future plans, the results of this test and supplementary test will be submitted to ACI349 committee as backup data to revise the standard for yield strength of high-strength rebar

  14. Beam Test for Evaluating Applicabillity of High - Strength Reinforcement in Structure of Nuclear Facility

    Energy Technology Data Exchange (ETDEWEB)

    Yim, Sangjun; Lee, Byungsoo; Bang, Changjoon [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2014-05-15

    The high-strength rebar which has high yield strength can reduce the amount of rebar in concrete and widen its spacing so that it has better workability and higher economic benefits for the structure. However, the maximum yield strength of rebar is limited to 420MPa in the design criteria for structure of nuclear facility in Korea and USA. Korea Hydro and Nuclear Power is progressing research to revise the limitation in the yield strength of rebar, which is suggested in the criteria of KEPIC and ACI, in order to apply 550 MPa high-strength rebar for the construction of a nuclear facility. This study is to review the applicability of high strength rebar in structure of a nuclear facility through a model beam test. After reviewing the shear capacity and reinforcement yield to assess the applicability of high-strength reinforcement in the structure of a nuclear facility, we make the following conclusions. When using high shear reinforcement with wider spacing, it has a similar shear capacity to normal reinforcement with narrower spacing. This means better workability and economic benefits can be achieved by widening the rebar spacing without brittle fracture in the elements. For future plans, the results of this test and supplementary test will be submitted to ACI349 committee as backup data to revise the standard for yield strength of high-strength rebar.

  15. Hip strength and star excursion balance test deficits of patients with chronic ankle instability.

    Science.gov (United States)

    McCann, Ryan S; Crossett, Ian D; Terada, Masafumi; Kosik, Kyle B; Bolding, Brenn A; Gribble, Phillip A

    2017-11-01

    To examine isometric hip strength in those with and without CAI, and determine the degree of Star Excursion Balance Test (SEBT) variance explained by isometric hip strength. Single-blinded, cross-sectional, case-control study. Thirty individuals with CAI, 29 lateral ankle sprain (LAS) copers, and 26 healthy controls participated. We assessed dynamic postural control with the SEBT anterior (SEBT-ANT), posteromedial (SEBT-PM), and posterolateral (SEBT-PL) reaches, and isometric hip extension (EXT), abduction (ABD) and external rotation (ER) strength with hand-held dynamometry. The CAI and LAS coper groups' involved limbs and randomly selected limbs in controls were tested. Separate Kruskal-Wallis tests compared SEBT scores and isometric hip strength between groups. Backwards linear regression models determined the degree of SEBT variance explained by isometric hip strength. Statistical significance was set a priori at Phip strength compared to LAS copers and controls. Additionally, the CAI group's isometric hip strength significantly influenced dynamic postural control performance. Future CAI rehabilitation strategies should consider hip muscular strengthening to facilitate improvements in dynamic postural control. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. [Effects of education and strength training on functional tests among older people with osteoarthritis].

    Science.gov (United States)

    Jiménez S, Christian Edgardo; Fernández G, Rubén; Zurita O, Félix; Linares G, Daniel; Farías M, Ariel

    2014-04-01

    Hip and knee osteoarthritis are important causes of pain and disability among older people. Education and strength training can alleviate symptoms and avoid functional deterioration. To assess muscle strength, fall risk and quality of life of older people with osteoarthritis and the effects of physiotherapy education and strength training on these variables. Thirty participants aged 78 ± 5 years (63% women) were randomly assigned to receive physiotherapy (Controls), physiotherapy plus education (Group 1) and physiotherapy plus strength training (group 2). At baseline and after 16 weeks of intervention, patients were evaluated with the Senior Fitness Test, Timed Up and Go and Quality of Life score short form (SF-36). During the intervention period, Senior Fitness Test and Timed Up and Go scores improved in all groups and SF-36 did not change. The improvement in Senior Fitness Test and Timed Up and Go was more marked in Groups 1 and 2 than in the control group. Education and strength training improve functional tests among older people with osteoarthritis.

  17. Optimal Scoring Methods of Hand-Strength Tests in Patients with Stroke

    Science.gov (United States)

    Huang, Sheau-Ling; Hsieh, Ching-Lin; Lin, Jau-Hong; Chen, Hui-Mei

    2011-01-01

    The purpose of this study was to determine the optimal scoring methods for measuring strength of the more-affected hand in patients with stroke by examining the effect of reducing measurement errors. Three hand-strength tests of grip, palmar pinch, and lateral pinch were administered at two sessions in 56 patients with stroke. Five scoring methods…

  18. Development of K-Basin High-Strength Homogeneous Sludge Simulants and Correlations Between Unconfined Compressive Strength and Shear Strength

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Yasuo; Baer, Ellen BK; Chun, Jaehun; Yokuda, Satoru T.; Schmidt, Andrew J.; Sande, Susan; Buchmiller, William C.

    2011-02-20

    K-Basin sludge will be stored in the Sludge Transport and Storage Containers (STSCs) at an interim storage location on Central Plateau before being treated and packaged for disposal. During the storage period, sludge in the STSCs may consolidate/agglomerate, potentially resulting in high-shear-strength material. The Sludge Treatment Project (STP) plans to use water jets to retrieve K-Basin sludge after the interim storage. STP has identified shear strength to be a key parameter that should be bounded to verify the operability and performance of sludge retrieval systems. Determining the range of sludge shear strength is important to gain high confidence that a water-jet retrieval system can mobilize stored K-Basin sludge from the STSCs. The shear strength measurements will provide a basis for bounding sludge properties for mobilization and erosion. Thus, it is also important to develop potential simulants to investigate these phenomena. Long-term sludge storage tests conducted by Pacific Northwest National Laboratory (PNNL) show that high-uranium-content K-Basin sludge can self-cement and form a strong sludge with a bulk shear strength of up to 65 kPa. Some of this sludge has 'paste' and 'chunks' with shear strengths of approximately 3-5 kPa and 380-770 kPa, respectively. High-uranium-content sludge samples subjected to hydrothermal testing (e.g., 185 C, 10 hours) have been observed to form agglomerates with a shear strength up to 170 kPa. These high values were estimated by measured unconfined compressive strength (UCS) obtained with a pocket penetrometer. Due to its ease of use, it is anticipated that a pocket penetrometer will be used to acquire additional shear strength data from archived K-Basin sludge samples stored at the PNNL Radiochemical Processing Laboratory (RPL) hot cells. It is uncertain whether the pocket penetrometer provides accurate shear strength measurements of the material. To assess the bounding material strength and

  19. Handgrip strength test as a complementary tool in monitoring asthma in daily clinical practice in children.

    Science.gov (United States)

    Latorre-Román, Pedro Ángel; Navarro-Martínez, Ana Vanesa; Mañas-Bastidas, Alfonso; García-Pinillos, Felipe

    2014-12-01

    The aim of this study was to demonstrate that handgrip strength test can discriminate the presence/absence of asthma and between intermittent and moderate persistent asthma in children. 140 children (70 healthy and 70 with asthma) completed the Pediatric Asthma Quality of Life Questionnaire (PAQLQ) and performed the handgrip strength test. Forty-eight hours later, subjects performed spirometry. The results showed Handgrip strength was significantly lower (pstrength test was a predictive factor for asthma (cut-off at 16.84 kg) and for severity of pathology (cut-off at 15.06 kg). Handgrip strength was reduced in children with asthma. Handgrip strength was positively associated with lung capacity and quality of life. The fact that the handgrip strength test was able to discriminate between presence/absence of asthma and between intermittent and moderate persistent asthma in children suggested that this test could be used as a complementary tool in the monitoring of asthma in daily clinical practice.

  20. Quadrupole decay strength of the M1 scissors mode

    Science.gov (United States)

    Beck, T.; Beller, J.; Derya, V.; Gayer, U.; Isaak, J.; Löher, B.; Mertes, L.; Pietralla, N.; Ries, P.; Romig, C.; Savran, D.; Scheck, M.; Tornow, W.; Weller, H. R.; Werner, V.; Zweidinger, M.

    2015-10-01

    The E2/M1 multipole mixing ratio δ1→2 of the 1sc +→21+ transition of Gd was determined using results from high-statistics photon scattering. This provides a possibility for a new approach on the search of Jsc + members of the rotational band built on the scissors mode. By application of Alaga's rule, which is justifiable as 156Gd is a well-deformed rotor with good K quantum number, a transition strength of B (E 2 ;2sc +→01+)=0.034 (13 ) W.u. is estimated.

  1. Adhesion strength study of IBAD-MOCVD-based 2G HTS wire using a peel test

    International Nuclear Information System (INIS)

    Zhang, Y.; Hazelton, D.W.; Knoll, A.R.; Duval, J.M.; Brownsey, P.; Repnoy, S.; Soloveichik, S.; Sundaram, A.; McClure, R.B.; Majkic, G.; Selvamanickam, V.

    2012-01-01

    A peel test was used to study the adhesion strength of a commercial grade 2G HTS wire which features a characteristic multilayer structure with the rare earth-based MOCVD superconducting film deposited on an IBAD-MgO template. The peel test could be carried out at various peeling angles (from 90° to 180°) and the peel strength of a wire was defined as the steady-state peeling load determined from a load-displacement curve. The test results had good reproducibility and accuracy, making the test a reliable and useful method for studying the adhesion strength of the wire. By characterizing the peeled surfaces the weakest interface in a wire could be identified. The peel strength data of the wire was analyzed together with the performance of the experimental magnet coils fabricated using the wire. The effect of the silver contact layer annealing on the peel strength is discussed.

  2. 47 CFR 18.305 - Field strength limits.

    Science.gov (United States)

    2010-10-01

    ...) Field strength limit (uV/m) Distance (meters) Any type unless otherwise specified (miscellaneous) Any...Any 2515 300300 Ultrasonic Below 490 kHz Below 500500 or more 2,400/F(kHz)2,400/F(kHz)× SQRT(power/500... kHzOn or above 90 kHz AnyAny 1,500300 430 430 1 Field strength may not exceed 10 μV/m at 1600 meters...

  3. Effect of Luting Cements On the Bond Strength to Turkom-Cera All-Ceramic Material

    Science.gov (United States)

    Al–Makramani, Bandar M. A.; Razak, Abdul A. A.; Abu–Hassan, Mohamed I.; Al–Sanabani, Fuad A.; Albakri, Fahad M.

    2018-01-01

    BACKGROUND: The selection of the appropriate luting cement is a key factor for achieving a strong bond between prepared teeth and dental restorations. AIM: To evaluate the shear bond strength of Zinc phosphate cement Elite, glass ionomer cement Fuji I, resin-modified glass ionomer cement Fuji Plus and resin luting cement Panavia-F to Turkom-Cera all-ceramic material. MATERIALS AND METHODS: Turkom-Cera was used to form discs 10mm in diameter and 3 mm in thickness (n = 40). The ceramic discs were wet ground, air - particle abraded with 50 - μm aluminium oxide particles and randomly divided into four groups (n = 10). The luting cement was bonded to Turkom-Cera discs as per manufacturer instructions. The shear bond strengths were determined using the universal testing machine at a crosshead speed of 0.5 mm/min. The data were analysed using the tests One Way ANOVA, the nonparametric Kruskal - Wallis test and Mann - Whitney Post hoc test. RESULTS: The shear bond strength of the Elite, Fuji I, Fuji Plus and Panavia F groups were: 0.92 ± 0.42, 2.04 ± 0.78, 4.37 ± 1.18, and 16.42 ± 3.38 MPa, respectively. There was the statistically significant difference between the four luting cement tested (p < 0.05). CONCLUSION: the phosphate-containing resin cement Panavia-F exhibited shear bond strength value significantly higher than all materials tested. PMID:29610618

  4. Percentage Level of Tannin fur Rabbit for Leather Concerning Stitch Tearing Strength, Tearing Strength and Flexibility

    Directory of Open Access Journals (Sweden)

    Mustakim Mustakim

    2012-02-01

    Full Text Available The purpose of this study was to find out the appropriate of tannin level for rabbit fur leather concerning stitch tearing strength, tearing strength, and flexibility. The result were expected to contribute good information for the society, leather craftsman, and further researchers about fur leather tanning especially rabbit fur leather with tannin concerning stitch tearing strength, tearing strength and flexibility. The material that used were 12 pieces of four months of rabbit skin. The research method was Completely Randomized Design, consist of three treatments of tannin, they were: M1 (mimosa 15%, M2 (mimosa 20%, and M3 (mimosa 25%. Each of treatment hold on four repetition, the variables which measured were stitch tearing strength, tearing strength, and flexibility of fur leather. Data were  analysed by analysis variance followed by Duncan’s Multiple Range Test. The result of this research indicate that the use level of tannin give significant influence (P<0.05 among stitch tearing strength, tearing strength. It gave a very significant influence (P<0.01 for flexibility of rabbit fur leather. Based on the result, can be concluded that 25 % of tannin (mimosa, produce the best  result on stitch tearing strength and tearing strength. The increase of tannin offer will decrease the flexibility of fur leather but the lowest tannin produced the best flexibility of fur leather (15 percent. The best quality of rabbit fur leather produced by 25 % of tannin.   Keywords : leather, tannin, quality

  5. Strength, running speed, agility and balance profiles of 9- to 10-year ...

    African Journals Online (AJOL)

    The purpose of this study was to determine the strength, running speed and agility, and balance profiles of 9- to 10-year old learners and the relation between these skills of the learners. Using a stratified random selection from 20 schools with different socio-economic backgrounds, 862 9- to 10-year-old learners (457 boys; ...

  6. Effect of Strength Training on Rate of Force Development in Older Women

    Science.gov (United States)

    Gurjao, Andre Luiz Demantova; Gobbi, Lilian Teresa Bucken; Carneiro, Nelson Hilario; Goncalves, Raquel; Ferreira de Moura, Rodrigo; Cyrino, Edilson Serpeloni; Altimari, Leandro Ricardo; Gobbi, Sebastiao

    2012-01-01

    We analyzed the effect of an 8-week strength training (ST) program on the rate of force development (RFD) and electromyographic activity (EMG) in older women. Seventeen women (M age = 63.4 years, SD = 4.9) without previous ST experience were randomly assigned to either a control (n = 7) or training (n = 10) group. A leg-press isometric test was…

  7. A Cluster Randomized Controlled Trial Testing the Effectiveness of Houvast: A Strengths-Based Intervention for Homeless Young Adults

    Science.gov (United States)

    Krabbenborg, Manon A. M.; Boersma, Sandra N.; van der Veld, William M.; van Hulst, Bente; Vollebergh, Wilma A. M.; Wolf, Judith R. L. M.

    2017-01-01

    Objective: To test the effectiveness of Houvast: a strengths-based intervention for homeless young adults. Method: A cluster randomized controlled trial was conducted with 10 Dutch shelter facilities randomly allocated to an intervention and a control group. Homeless young adults were interviewed when entering the facility and when care ended.…

  8. Test Results and Comparison of Triaxial Strength Testing of Waste Isolation Pilot Plant Clean Salt

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Stuart A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    This memorandum documents laboratory thermomechanical triaxial strength testing of Waste Isolation Pilot Plant (WIPP) clean salt. The limited study completed independent, adjunct laboratory tests in the United States to assist in validating similar testing results being provided by the German facilities. The testing protocol consisted of completing confined triaxial, constant strain rate strength tests of intact WIPP clean salt at temperatures of 25°C and 100°C and at multiple confining pressures. The stratigraphy at WIPP also includes salt that has been labeled “argillaceous.” The much larger test matrix conducted in Germany included both the so-called clean and argillaceous salts. When combined, the total database of laboratory results will be used to develop input parameters for models, assess adequacy of existing models, and predict material behavior. These laboratory studies are also consistent with the goals of the international salt repository research program. The goal of this study was to complete a subset of a test matrix on clean salt from the WIPP undertaken by German research groups. The work was performed at RESPEC in Rapid City, South Dakota. A rigorous Quality Assurance protocol was applied, such that corroboration provides the potential of qualifying all of the test data gathered by German research groups.

  9. Adhesion strength study of IBAD-MOCVD-based 2G HTS wire using a peel test

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Y., E-mail: yzhang@superpower-inc.com [SuperPower Inc., 450 Duane Avenue, Schenectady, NY 12304 (United States); Hazelton, D.W.; Knoll, A.R.; Duval, J.M.; Brownsey, P.; Repnoy, S.; Soloveichik, S.; Sundaram, A.; McClure, R.B. [SuperPower Inc., 450 Duane Avenue, Schenectady, NY 12304 (United States); Majkic, G.; Selvamanickam, V. [University of Houston, 4800 Calhoun Road, Houston, TX 77204 (United States)

    2012-02-15

    A peel test was used to study the adhesion strength of a commercial grade 2G HTS wire which features a characteristic multilayer structure with the rare earth-based MOCVD superconducting film deposited on an IBAD-MgO template. The peel test could be carried out at various peeling angles (from 90 Degree-Sign to 180 Degree-Sign) and the peel strength of a wire was defined as the steady-state peeling load determined from a load-displacement curve. The test results had good reproducibility and accuracy, making the test a reliable and useful method for studying the adhesion strength of the wire. By characterizing the peeled surfaces the weakest interface in a wire could be identified. The peel strength data of the wire was analyzed together with the performance of the experimental magnet coils fabricated using the wire. The effect of the silver contact layer annealing on the peel strength is discussed.

  10. Design of High Voltage Electrical Breakdown Strength measuring system at 1.8K with a G-M cryocooler

    Science.gov (United States)

    Li, Jian; Huang, Rongjin; Li, Xu; Xu, Dong; Liu, Huiming; Li, Laifeng

    2017-09-01

    Impregnating resins as electrical insulation materials for use in ITER magnets and feeder system are required to be radiation stable, good mechanical performance and high voltage electrical breakdown strength. In present ITER project, the breakdown strength need over 30 kV/mm, for future DEMO reactor, it will be greater than this value. In order to develop good property insulation materials to satisfy the requirements of future fusion reactor, high voltage breakdown strength measurement system at low temperature is necessary. In this paper, we will introduce our work on the design of this system. This measuring system has two parts: one is an electrical supply system which provides the high voltage from a high voltage power between two electrodes; the other is a cooling system which consists of a G-M cryocooler, a superfluid chamber and a heat switch. The two stage G-M cryocooler pre-cool down the system to 4K, the superfluid helium pot is used for a container to depress the helium to superfluid helium which cool down the sample to 1.8K and a mechanical heat switch connect or disconnect the cryocooler and the pot. In order to provide the sufficient time for the test, the cooling system is designed to keep the sample at 1.8K for 300 seconds.

  11. Test-Retest Reliability of Handgrip Strength as an Outcome Measure in Patients With Symptoms of Shoulder Impingement Syndrome.

    Science.gov (United States)

    Savva, Christos; Mougiaris, Paraskevas; Xadjimichael, Christoforos; Karagiannis, Christos; Efstathiou, Michalis

    The purpose of this study was to investigate the degree of test-retest reliability of grip strength measurement using a hand dynamometer in patients with shoulder impingement syndrome. A total of 19 patients (10 women and 9 men; mean ± standard deviation age, 33.2 ± 12.9 years; range 18-59 years) with shoulder impingement syndrome were measured using a hand dynamometer by the same data collector in 2 different testing sessions with a 7-day interval. During each session, patients were encouraged to exert 3 maximal isometric contractions on the affected hand and the mean value of the 3 efforts (measured in kilogram-force [Kgf]) was used for data analysis. The intraclass correlation coefficient (ICC 2,1 ) as well as the standard error of measurement (SEM) and Bland-Altman plot were used to estimate the degree of test-retest reliability and the measurement error, respectively. Grip strength data analysis revealed an ICC 2,1 score of 0.94, which, based on the Shrout classification, is considered as excellent test-retest reliability of grip strength measurement. The small values of SEMs reported in both sessions (SEM 1 , 2.55 Kgf; SEM 2 , 2.39 Kgf) and the small width of the 95% limits of agreement in the Bland-Altman plot (ranging from -7.39 Kgf to 7.03 Kgf) reflected the measurement precision and the narrow variation of the differences during the 2 testing sessions. Results from this study identified excellent test-retest reliability of grip strength measurement in shoulder impingement syndrome, indicating its potential use as an outcome measure in clinical practice. Copyright © 2018. Published by Elsevier Inc.

  12. Test Operations Procedure (TOP) 05-2-543 Enhanced Flight Termination Receiver (EFTR) Range Certification Testing

    Science.gov (United States)

    2011-07-25

    35 5.10 Signal Strength Telemetry Output ( SSTO ) (Test Number 10) ............ 38 5.11 Operational...All command outputs and monitor outputs shall respond properly. TOP 05-2-543 25 July 2011 38 5.10 Signal Strength Telemetry Output ( SSTO ...Test Number 10). a. Purpose. This test verifies that the signal strength telemetry output ( SSTO ) voltage is monotonic and directly related to the

  13. Accelerated Creep Testing of High Strength Aramid Webbing

    Science.gov (United States)

    Jones, Thomas C.; Doggett, William R.; Stnfield, Clarence E.; Valverde, Omar

    2012-01-01

    A series of preliminary accelerated creep tests were performed on four variants of 12K and 24K lbf rated Vectran webbing to help develop an accelerated creep test methodology and analysis capability for high strength aramid webbings. The variants included pristine, aged, folded and stitched samples. This class of webbings is used in the restraint layer of habitable, inflatable space structures, for which the lifetime properties are currently not well characterized. The Stepped Isothermal Method was used to accelerate the creep life of the webbings and a novel stereo photogrammetry system was used to measure the full-field strains. A custom MATLAB code is described, and used to reduce the strain data to produce master creep curves for the test samples. Initial results show good correlation between replicates; however, it is clear that a larger number of samples are needed to build confidence in the consistency of the results. It is noted that local fiber breaks affect the creep response in a similar manner to increasing the load, thus raising the creep rate and reducing the time to creep failure. The stitched webbings produced the highest variance between replicates, due to the combination of higher local stresses and thread-on-fiber damage. Large variability in the strength of the webbings is also shown to have an impact on the range of predicted creep life.

  14. Testes de força e resistência muscular: confiabilidade e predição de uma repetição máxima - Revisão e novas evidências Tests de fuerza y resistencia muscular: confiabilidad de la prediccion de una repeticion máxima - Revision y nuevas evidencias Muscular strength and endurance tests: reliability and prediction of one repetition maximum - Review and new evidences

    Directory of Open Access Journals (Sweden)

    Marta Inez Rodrigues Pereira

    2003-10-01

    Full Text Available A confiabilidade intra-avaliadores é fundamental na determinação da qualidade dos dados coletados em uma pesquisa. Poucos estudos controlados têm reportado valores de confiabilidade de testes de força e, apesar de esta ser considerada boa na maioria dos estudos publicados (0,79 a 0,99, as diferenças entre teste e reteste têm sido observadas como estatisticamente significativas. Dessa forma, sugere-se a utilização dos valores de um segundo teste, pelo menos, em estudos de pesquisa, de modo que eventuais modificações nos valores de força possam ser atribuídas ao efeito dos tratamentos realizados e não à simples adaptação ao protocolo de teste. As relações entre testes de força máxima e testes submáximos ou variáveis antropométricas têm sido investigadas com o intuito de predizer a força máxima sem que o indivíduo tenha que ser submetido a um teste de carga máxima, evitando possíveis riscos de lesão. Valores de carga máxima, ou percentuais desta, são comumente utilizados para melhor prescrever o treinamento. A predição de uma repetição máxima (1RM através de testes submáximos parece boa (em geral, correlações > 0,90; entretanto, na maioria dos estudos revisados, as equações preditivas desenvolvidas quase sempre não são aprovadas no escrutínio de uma validação cruzada. Assim sendo, especial atenção deve ser dispensada à especificidade da população, do exercício e da técnica de execução, quando do desenvolvimento e aplicação dessas equações. Variáveis antropométricas não foram confirmadas como boas preditoras de 1RM. O número de repetições para dado % de 1RM é diferente para diferentes exercícios, como também o é a carga para determinado número de repetições máximas (nRM, quando executadas em diferentes velocidades. A prescrição do exercício baseada, indiferentemente, em número de repetições ou % de 1RM deve ser considerada com cautela.La confiabilidad entre los

  15. Characteristics of structural loess strength and preliminary framework for joint strength formula

    OpenAIRE

    Rong-jian Li; Jun-ding Liu; Rui Yan; Wen Zheng; Sheng-jun Shao

    2014-01-01

    The strength of structural loess consists of the shear strength and tensile strength. In this study, the stress path, the failure envelope of principal stress (Kf line), and the strength failure envelope of structurally intact loess and remolded loess were analyzed through three kinds of tests: the tensile strength test, the uniaxial compressive strength test, and the conventional triaxial shear strength test. Then, in order to describe the tensile strength and shear strength of structural lo...

  16. Triaxiality and alternating M1 strengths in f-p-g shell nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Tabor, S L; Johnson, T D; Holcombe, J W; Womble, P C; Doring, J; Nazarewicz, W [Florida State Univ., Tallahassee, FL (United States). Dept. of Physics

    1992-08-01

    The appearance of alternating patterns in B(M1) strengths in f-p-g shell nuclei is surveyed. The M1 alternations in a sequence of N= 41 isotones, in conjunction with particle-rotor model calculations, is shown to provide information about changing {gamma} deformation. In addition to other odd-A nuclei, several odd-odd nuclei are shown to exhibit alternating B(M1) values and signature inversion. alternations have also been reported in a 4 quasiparticle band in {sup 86}Zr, where they have been interpreted in terms of the interacting boson model. (author). 15 refs., 1 tab., 6 figs.

  17. Clinical tests of ankle plantarflexor strength do not predict ankle power generation during walking.

    Science.gov (United States)

    Kahn, Michelle; Williams, Gavin

    2015-02-01

    The aim of this study was to investigate the relationship between a clinical test of ankle plantarflexor strength and ankle power generation (APG) at push-off during walking. This is a prospective cross-sectional study of 102 patients with traumatic brain injury. Handheld dynamometry was used to measure ankle plantarflexor strength. Three-dimensional gait analysis was performed to quantify ankle power generation at push-off during walking. Ankle plantarflexor strength was only moderately correlated with ankle power generation at push-off (r = 0.43, P < 0.001; 95% confidence interval, 0.26-0.58). There was also a moderate correlation between ankle plantarflexor strength and self-selected walking velocity (r = 0.32, P = 0.002; 95% confidence interval, 0.13-0.48). Handheld dynamometry measures of ankle plantarflexor strength are only moderately correlated with ankle power generation during walking. This clinical test of ankle plantarflexor strength is a poor predictor of calf muscle function during gait in people with traumatic brain injury.

  18. Test of QED at critical field strength

    Energy Technology Data Exchange (ETDEWEB)

    Bula, C. [Princeton Univ., NJ (United States)

    1997-01-01

    In a new experiment at the Final Focus Test Beam at SLAC, a low-emittance 46.6 GeV electron beam is brought into collisions with terawatt pulses of 1054 nm or 527 nm wavelength from a Nd:glass laser. Peak laser intensities of 10{sup 18} W/cm{sup 2} have been achieved corresponding to a value of 0.6 for the parameter {eta} = e{epsilon}/m{omega}{sub 0}c. In this case, an electron that crosses the center of the laser pulse has near-unit interaction probability. Results are presented for multiphoton Compton scattering in which an electron interacts with up to four laser photons, in agreement with theoretical calculations.

  19. Hand Grip Strength Vs. Sprint Effectiveness in Amputee Soccer Players.

    Science.gov (United States)

    Wieczorek, Marta; Wiliński, Wojciech; Struzik, Artur; Rokita, Andrzej

    2015-11-22

    Amputee soccer is one of the types of soccer designed for the disabled, especially those who have undergone amputations, as well as those with extremity dysfunction. The objective of the study was to find the relationship between hand grip strength and sprint time in amputee soccer players. Thirteen field amputee soccer players participated in the study. A SAEHAN hydraulic hand dynamometer manufactured by Jamar was used for hand grip strength measurements. The sprint running test was conducted over a distance of 30 m. The Fusion Smart Speed System was employed for running time measurements. No statistically significant relationships were found between hand grip strength of the left or right hand, and sprint times over 1, 5, 10, 15, 20, 25 and 30 m. Analysis of the running velocity curve of the subjects showed an interesting profile characterized by a 15 meter-long acceleration phase and a significant velocity increase over a distance of 20 - 25 m. The study suggests that there is no relationship between hand grip strength and sprint effectiveness in amputee soccer players. The specificity of locomotion with the use of elbow crutches among elite Polish amputee soccer players probably accounts for the profile of the sprint velocity curve. Extension of the acceleration phase in the sprint run and a velocity increase in the subsequent part of the run were observed.

  20. Hand Grip Strength Vs. Sprint Effectiveness in Amputee Soccer Players

    Directory of Open Access Journals (Sweden)

    Wieczorek Marta

    2015-12-01

    Full Text Available Amputee soccer is one of the types of soccer designed for the disabled, especially those who have undergone amputations, as well as those with extremity dysfunction. The objective of the study was to find the relationship between hand grip strength and sprint time in amputee soccer players. Thirteen field amputee soccer players participated in the study. A SAEHAN hydraulic hand dynamometer manufactured by Jamar was used for hand grip strength measurements. The sprint running test was conducted over a distance of 30 m. The Fusion Smart Speed System was employed for running time measurements. No statistically significant relationships were found between hand grip strength of the left or right hand, and sprint times over 1, 5, 10, 15, 20, 25 and 30 m. Analysis of the running velocity curve of the subjects showed an interesting profile characterized by a 15 meter-long acceleration phase and a significant velocity increase over a distance of 20 – 25 m. The study suggests that there is no relationship between hand grip strength and sprint effectiveness in amputee soccer players. The specificity of locomotion with the use of elbow crutches among elite Polish amputee soccer players probably accounts for the profile of the sprint velocity curve. Extension of the acceleration phase in the sprint run and a velocity increase in the subsequent part of the run were observed.

  1. Acute Effects of Partial-Body Cryotherapy on Isometric Strength: Maximum Handgrip Strength Evaluation.

    Science.gov (United States)

    De Nardi, Massimo; Pizzigalli, Luisa; Benis, Roberto; Caffaro, Federica; Micheletti Cremasco, Margherita

    2017-12-01

    De Nardi, M, Pizzigalli, L, Benis, R, Caffaro, F, and Cremasco, MM. Acute effects of partial-body cryotherapy on isometric strength: maximum handgrip strength evaluation. J Strength Cond Res 31(12): 3497-3502, 2017-The aim of the study was to evaluate the influence of a single partial-body cryotherapy (PBC) session on the maximum handgrip strength (JAMAR Hydraulic Hand dynamometer). Two hundred healthy adults were randomized into a PBC group and a control group (50 men and 50 women in each group). After the initial handgrip strength test (T0), the experimental group performed a 150-second session of PBC (temperature range between -130 and -160° C), whereas the control group stayed in a thermo neutral room (22.0 ± 0.5° C). Immediately after, both groups performed another handgrip strength test (T1). Data underlined that both groups showed an increase in handgrip strength values, especially the experimental group (Control: T0 = 39.48 kg, T1 = 40.01 kg; PBC: T0 = 39.61 kg, T1 = 41.34 kg). The analysis also reported a statistical effect related to gender (F = 491.99, P ≤ 0.05), with women showing lower handgrip strength values compared with men (women = 30.43 kg, men = 52.27 kg). Findings provide the first evidence that a single session of PBC leads to the improvement of muscle strength in healthy people. The results of the study imply that PBC could be performed also before a training session or a sport competition, to increase hand isometric strength.

  2. Milestone 5 test report. Task 5, subtask 5.2: Tile to foam strength tests

    Science.gov (United States)

    Greenberg, H. S.

    1994-01-01

    This report summarizes work that has been performed to date on the strength of a cryotank insulation system using Rohacell foam and TUFI-coated AETB-12 ceramic tiles directly bonded to a simulated graphite-epoxy tank wall. Testing utilized a custom specimen design which consists of a long tensile specimen with eccentric loading to induce curvature similar to the curvature expected due to 'pillowing' of the tank when pressurized. A finite element model was constructed to predict the specific element strains in the test article, and to assist with design of the test specimen to meet the specific goals of curvature and laminate strain. The results indicate that the heat treated 3.25-pcf density Rohacell foam does not provide sufficient strength for the induced stresses due to curvature and stress concentration at the RTV bondline to the TUFI tile. The test was repeated using higher density non-heat treated Rohacell foam (6.9 pcf) without foam failure. The finite element model was shown to predict specimen behavior, and validation of the model was successful. It is pertinent to mention that the analyses described herein accurately predicted the failure of the heat treated foams and based on this analysis method it is expected that the untreated 3.25 pcf Rohacell foam will be successful.

  3. Reliability of isometric subtalar pronator and supinator strength testing.

    Science.gov (United States)

    Hagen, Marco; Lahner, Matthias; Winhuysen, Martin; Maiwald, Christian

    2015-01-01

    Due to the specific anatomy of the subtalar joint with its oblique axis, isometric pronator and supinator strength is not well documented. The purpose of this study was to determine intra- and between-session reliability of pronator and supinator strength and lower leg muscle activity measurements during maximum voluntary isometric contractions (MVIC). Pronator and supinator peak torques (PT), with and without supplementary visual muscle strength biofeedback (FB), and muscular activities of peroneus longus (PL) and tibialis anterior (TA) were assessed twice 3 days apart by the same examiner in 21 healthy young male adults (mean age: 27.6 years; SD = 3.9). Limits of agreement (LoA) and minimum detectable change (MDC) were evaluated. By applying FB, reliability of both pronator and supinator PT was improved: LoA were reduced from 32% to 26% and from 20% to 18% and MDC from 20% to 15% and from 16% to 12% in supinator and pronator PT, respectively. Learning effects in pronator and supinator PT (p isometric subtalar pronator and supinator strength testing is reliable in healthy subjects. LoA of 18% and 26% have to be exceeded for pronator and supinator PT, respectively, to detect relevant effects in repeated measures.

  4. Strength Performance of Blended Ash Based Geopolymer Mortar

    Science.gov (United States)

    Zahib, Zaidahtulakmal M.; Kamaruddin, Kartini; Saman, Hamidah M.

    2018-03-01

    Geopolymer is a based on inorganic alumino-silicate binder system. Geopolymeric materials are formed using materials that containing silica and aluminium such as fly ash and rice husk ash, which activated by alkaline solution. This paper presents the study on the effect of replacement of SSA in RHA based geopolymer, types of curing and different molarity of NaOH used on the strength of Sewage Sludge Ash (SSA) and Rice Husk Ash (RHA) based geopolymer mortar incorporating with three (3) different mix proportions. Based geopolymer mortar was synthesized from treated sewage sludge and rice husk undergoing incineration process in producing ashes, activated with sodium silicate and sodium hydroxide solution by ratio of 2.5:1 and solution to ash ratio of 1:1. Molarity of 8M and 10M NaOH were used. The percentages of SSA replacement were 0%, 10% and 20% by weight. Compressive strength was conducted at age 7, 14 and 28 days to see the development of strength with two curing regimes, which are air curing and oven curing (60°C for 24 hours). From the research conducted, the ultimate compressive strength (6.28MPa) was obtained at zero replacement of SSA taken at 28 days of oven curing with 10M of NaOH. This shows that RHA, which is rich in silica content is enough to enhance the strength of geopolymer mortar especially with high molarity of NaOH.

  5. Testing of High Thermal Cycling Stability of Low Strength Concrete as a Thermal Energy Storage Material

    Directory of Open Access Journals (Sweden)

    Chao Wu

    2016-09-01

    Full Text Available Concrete has the potential to become a solution for thermal energy storage (TES integrated in concentrating solar power (CSP systems due to its good thermal and mechanical properties and low cost of material. In this study, a low strength concrete (C20 is tested at high temperatures up to 600 °C. Specimens are thermally cycled at temperatures in the range of 400–300 °C, 500–300 °C, and 600–300 °C, which TES can reach in operation. For comparison, specimens also cycled at temperature in the range of 400–25 °C (room temperature, 500–25 °C, and 600–25 °C. It is found from the test results that cracks are not observed on the surfaces of concrete specimens until the temperature is elevated up to 500 °C. There is mechanical deterioration of concrete after exposure to high temperature, especially to high thermal cycles. The residual compressive strength of concrete after 10 thermal cycles between 600 °C and 300 °C is about 58.3%, but the specimens remain stable without spalling, indicating possible use of low strength concrete as a TES material.

  6. Correlation between explosive strength, aerobic power and repeated sprint ability in elite basketball players.

    Science.gov (United States)

    Stojanovic, M D; Ostojic, S M; Calleja-González, J; Milosevic, Z; Mikic, M

    2012-08-01

    The aim of this study was to examine the relationship between explosive strength and aerobic power with basketball-specific repeated sprint ability in elite male basketball players. Twenty-four elite basketball players (age 22.2±3.4 years, height 197.1±6.2 cm, weight 95.7±8.8 kg; training experience 11.0±3.1 years; mean±SD), participated in the study. Subjects performed countermovement jump (CMJ) test and incremental pseudo-ramp test protocol with measured CMJ height and VO2max, respectively. Specific repeated sprint ability (RSA) test was conducted, with total sprinting time (summation of 10 sprint times - RSAtot) and sprint decrement (fatigue index - RSAFI) calculated. Significant decrements in sprint performance from the eight 30-m sprint (Pbasketball players. It seems that coaches and strength and conditioning professionals should devote additional time for explosive strength development in elite basketball players during preparatory period to enhance RSA performance.

  7. Relación entre la fuerza máxima en squat y acciones de salto, sprint y golpeo de balón. (Relationship among maximal strength in squat exercise, jump, sprint and kicking ball performance.

    Directory of Open Access Journals (Sweden)

    Alfredo Arija Blázquez

    2008-01-01

    Full Text Available ResumenEl objetivo del presente estudio fue analizar las posibles relaciones entre la fuerza máxima en squat y accionesexplosivas de salto, sprint y golpeo de balón. Para ello, se contó con una muestra formada por estudiantes de Ciencias del Deporte (N= 16; 19,6 ± 1,7 años de sexo masculino (con escasa experiencia en el entrenamiento de fuerza, que llevaron a cabo un test de 1RM en squat (calculándose el peso levantado, la fuerza media total y la fuerza dinámica máxima, tests de salto vertical (SJ, CMJ y CMJa, un test de sprint de 20 m (con mediciones de tiempo cada 5 m, y un test de golpeo con el pie donde se calculaba la velocidad del balón. Se encontraron coeficientes de correlación moderados (entre 0,52 y 0,67 y significativos de las medidas de fuerza máxima y las alturas de salto, mientras que los coeficientes obtenidos entre los tiempos de sprint y dichas medidas de fuerza máxima se situaron entre -0,06 y -0,32, no siendo ninguno de ellos significativo; al igual que tampoco fueron significativos los coeficientes de correlación de las medidas de fuerza máxima y la velocidad de tiro, se situaron entre 0,25 y 0,34. Por tanto, la relación entre la fuerza máxima en squat y la altura de salto en sujetos con escasa experiencia en el entrenamiento de fuerza resultó moderada, mientras que no parece existir relación con el tiempo de sprint y la velocidad de tiro.AbstractThe purpose of the present study was to analyze the possible relationships between maximal strength insquat exercise and jump, sprint and kicking ball actions. Sixteen males sport science students (19,6 ± 1,7years, with little experience in strength training, performed a 1RM in squat exercise (from which liftedweight, the total average- and maximal-dynamic strength was assessed, vertical jump (SJ, CMJ and CMJa, a 20 m sprint test (with time measurement every 5 m, and a kicking ball test where the velocity of the ball was calculated. Moderate (0,52 - 0,67 and

  8. The Effect Of Coupling Agent On Composite Magnet Characteristic Based On Hexa ferrite (Sr M/Ba M) With Polyester And Epoxy Binder

    International Nuclear Information System (INIS)

    Sudirman; Ridwan; Mujamilah; Karo Karo, Aloma; Handayani, Ari; Rukihati

    2004-01-01

    Magnetic composites are mixtures of hexa ferrite powder and non magnetic materials such as polymers as binders. These composites have been investigated because they are light, elastic, and cheap. In this study thermoset polymer (epoxy and polyester) were used as binders. Inside study of coupling agent added effect on mechanical properties, hardness and microstructure. The composites were prepared by mixture thermoset polymer epoxy or polyester with hexa ferrite powder Sr M (SrFe 12 O 19 ) or Ba M (BaFe 12 O 19 ) with volume fraction of 40,50 and 60 % v/v, coupling agent of the Tetra Isopropyl Titanate in the amount of 5 ml or 10 ml are added before mix turing of the thermoset polymer epoxy or polyester with hexa ferrite powder. The resulting composite were characterized mechanically (tensile strength), hardness and microstructure test. The results showed that the tensile strength and hardness of the composite magnet were increased by increasing the composition of magnetic powder, either Sr M or Ba M, it caused by microstructure of particle Sr M magnetic powder 1.6 μm in the form splinter, where as the Ba M magnetic powder 1,2 μm in nodular form. Thermoset polymer epoxy as binder have tensile strength and hardness is bigger than composite magnet based on polyester, either Sr M or Ba M. The addition of coupling agent is very influenced on the tensile strength and hardness composite magnet, the more coupling magnet addition causes the more tensile strength and hardness of the composite magnet

  9. Comparative study of etched enamel and dentin for the adhesion of composite resins with the Er:YAG 2,94 μm laser and CO2 9,6 μm laser: morphological (SEM) and tensile bond strength analysis

    International Nuclear Information System (INIS)

    Marraccini, Tarso Mugnai

    2002-01-01

    The aim of this study was to evaluate and compare the tensile bond strength of a composite resin adhered to the enamel and dentin which have received superficial irradiation with an Er:YAG laser (2.94 μm) or with CO 2 laser ( 9.6 μm) and later on etched with the phosphoric acid at 35%. After the use of the adhesive system, resin cones were made on the etched surfaces by both lasers and tensile bond strength tests were performed. All samples were observed at the SEM - there was an increase of the degree of fusion and resolidification in the irradiated enamel and dentin samples with the CO 2 laser (9.6 μm), creating a vitrified layer with tiny craters. With the Er:YAG laser (2.94 μm) there were typical morphological explosive microablation with the exposition of the tubules in the dentin.The surface acquired by the association of the CO 2 laser ( 9.6 μm) plus acid etching no longer presented the aspect of fusion being this layer completely removed. There were statistical significant differences among ali three methods of etching in the treatment of the enamel and dentin surface. The tensile bond strength test showed that etching of these enamel and dentin surfaces with acid exclusively (control group) presented great values, surpassing the values of the etching acquired with the Er:YAG laser (2.94 μ) plus acid or the CO 2 laser (9.6 μm) plus acid. With the parameters used in this experiment the Er:YAG laser (2.94 μm) showed to be more effective than the CO 2 laser (9.6 μm) for the hard dental surfaces etching procedure. (author)

  10. An in vitro study to evaluate the effect of two ethanol-based and two acetone-based dental bonding agents on the bond strength of composite to enamel treated with 10% carbamide peroxide

    Directory of Open Access Journals (Sweden)

    Deepa Basavaraj Benni

    2014-01-01

    Full Text Available Background and Objective: Carbamide peroxide bleaching has been implicated in adversely affecting the bond strength of composite to enamel. The objective of this in vitro study was to evaluate the effect of ethanol-based (Clearfil S 3 bond, Kuraray, Adper Single bond 2, 3M ESPE dental products and acetone-based (Prime and Bond NT, Dentsply, One Step, Bisco bonding agents on the shear bond strength of composite to enamel treated with 10% carbamide peroxide bleaching agent. Materials and Methods: A total of 120 extracted human noncarious permanent incisors were randomly divided into two groups (control and experimental. Experimental group specimens were subjected to a bleaching regimen with a 10% carbamide peroxide bleaching system (Opalescence; Ultradent Products Inc, South Jordan, USA. Composite resin cylinders were bonded to the specimens using four bonding agents and shear bond strength was determined with universal testing machine. Results: There was no statistically significant difference in the shear bond strength between control and experimental groups with both ethanol-based (Clearfil S 3 Bond and Adper Single Bond 2 and acetone-based bonding agent (Prime and Bond NT and One Step. Interpretation and Conclusion: The adverse effect of bleaching on bonding composite to enamel can be reduced or eliminated by using either ethanol- or acetone-based bonding agent. Clinical Significances: Immediate bonding following bleaching procedure can be done using ethanol- or acetone-based bonding agent without compromising bond strength.

  11. Microstructure, Mechanical, and Fatigue Strength of Ti-54M Processed by Rotary Swaging

    Science.gov (United States)

    Al-Khazraji, Hasan; El-Danaf, Ehab; Wollmann, Manfred; Wagner, Lothar

    2015-05-01

    TIMETAL 54M is a newly developed (α + β) titanium alloy with nominal composition Ti-5Al-4V-0.6Mo-0.4Fe. The alloy can provide a cost benefit over Ti-6Al-4V due to improved machinability and formability. In the present work, evolution of mechanical properties in terms of tensile and hardness values is investigated as a function of deformation degrees imposed via rotary swaging (RS). Microstructure, mechanical properties, and fatigue performance of Ti-54M are investigated after severe plastic deformation by RS conducted at 850 °C and after being subjected to two different post-swaging annealing conditions. Optical microscopy and scanning electron microscopy using electron back scatter diffraction were utilized to document the evolution of the microstructure. Tensile tests were conducted to characterize mechanical properties. RS, to a true strain of 3.0, is found to lead to a marked ultrafine-grained structure of about 1 μm grain size with low content of high angle grain boundaries (HAGBs). Post-swaging heat treatment at 800 °C followed by air cooling did not change the grain size but exhibited high content of HAGBs. Post-swaging heat treatment at 940 °C followed by furnace cooling resulted in a grain size of about 5 μm and enhanced work-hardening capability and ductility, which resulted in less fatigue notch sensitivity, but at the same time lower fatigue strength at 107 cycles.

  12. Effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin.

    Science.gov (United States)

    Singh, Payal; Nagpal, Rajni; Singh, Udai Pratap

    2017-08-01

    This in vitro study evaluated the effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin. Flat coronal dentin surfaces were prepared in 120 extracted human molars. Teeth were randomly divided into 5 groups ( n = 24) according to 5 different surface pre-treatments: No pre-treatment (control); 1M carbodiimide (EDC); 0.1% epigallocatechin-3-gallate (EGCG); 2% minocycline (MI); 10% sodium ascorbate (SA). After surface pre-treatment, adhesive (Adper Single Bond 2 [SB], 3M ESPE) was applied. Composite was applied into transparent plastic tubes (2.5 mm in diameter), which was placed over the bonded dentin surface. From each group, 10 samples were subjected to shear bond strength (SBS) evaluation at 24 hours (immediate) and remaining 10 samples were tested after 6 months (delayed). Additionally, 4 samples per group were subjected to scanning electron microscopic analysis for observation of resin-dentin interface. The data were statistically analysed with Shaperio‑Wilk W test, 2-way analysis of variance (ANOVA), and post hoc Tukey's test. At 24 hours, SBS of all surface pre-treatment groups were comparable with the control group, with significant differences found between EDC and SA groups only ( p = 0.009). After 6 months storage, EDC, EGCG, and MI pre-treatments preserved the resin-dentin bond strength with no significant fall. Dentin pre-treatment with all the dentin biomodifiers except SA resulted in significant preservation of resin-dentin bond over 6 months storage period, without negatively affecting the immediate bond strength of the etch and rinse adhesive tested.

  13. Bond strength tests between silicon wafers and duran tubes (fusion bonded fluidic interconnects)

    NARCIS (Netherlands)

    Fazal, I.; Berenschot, Johan W.; de Boer, J.H.; Jansen, Henricus V.; Elwenspoek, Michael Curt

    2005-01-01

    The fusion bond strength of glass tubes with standard silicon wafers is presented. Experiments with plain silicon wafers and those coated with silicon oxide and silicon nitride are presented. Results obtained are discussed in terms of homogeneity and strength of fusion bond. High pressure testing

  14. Influence of the Testing Gage Length on the Strength, Young's Modulus and Weibull Modulus of Carbon Fibres and Glass Fibres

    Directory of Open Access Journals (Sweden)

    Luiz Claudio Pardini

    2002-10-01

    Full Text Available Carbon fibres and glass fibres are reinforcements for advanced composites and the fiber strength is the most influential factor on the strength of the composites. They are essentially brittle and fail with very little reduction in cross section. Composites made with these fibres are characterized by a high strength/density ratio and their properties are intrisically related to their microstructure, i.e., amount and orientation of the fibres, surface treatment, among other factors. Processing parameters have an important role in the fibre mechanical behaviour (strength and modulus. Cracks, voids and impurities in the case of glass fibres and fibrillar misalignments in the case of carbon fibres are created during processing. Such inhomogeneities give rise to an appreciable scatter in properties. The most used statistical tool that deals with this characteristic variability in properties is the Weibull distribution. The present work investigates the influence of the testing gage length on the strength, Young's modulus and Weibull modulus of carbon fibres and glass fibres. The Young's modulus is calculated by two methods: (i ASTM D 3379M, and (ii interaction between testing equipment/specimen The first method resulted in a Young modulus of 183 GPa for carbon fibre, and 76 GPa for glass fibre. The second method gave a Young modulus of 250 GPa for carbon fibre and 50 GPa for glass fibre. These differences revelead differences on how the interaction specimen/testing machine can interfere in the Young modulus calculations. Weibull modulus can be a tool to evaluate the fibre's homogeneity in terms of properties and it is a good quality control parameter during processing. In the range of specimen gage length tested the Weibull modulus for carbon fibre is ~ 3.30 and for glass fibres is ~ 5.65, which indicates that for the batch of fibres tested, the glass fibre is more uniform in properties.

  15. Determination of strength behaviour of slope supported by vegetated crib walls using centrifuge model testing

    Science.gov (United States)

    Sudan Acharya, Madhu

    2010-05-01

    The crib retaining structures made of wooden/bamboo logs with live plants inside are called vegetative crib walls which are now becoming popular due to their advantages over conventional civil engineering walls. Conventionally, wooden crib walls were dimensioned based on past experiences. At present, there are several guidelines and design standards for machine finished wooden crib walls, but only few guidelines for the design and construction of vegetative log crib walls are available which are generally not sufficient for an economic engineering design of such walls. Analytical methods are generally used to determine the strength of vegetated crib retaining walls. The crib construction is analysed statically by satisfying the condition of static equilibrium with acceptable level of safety. The crib wall system is checked for internal and external stability using conventional monolithic and silo theories. Due to limitations of available theories, the exact calculation of the strength of vegetated wooden/bamboo crib wall cannot be made in static calculation. Therefore, experimental measurements are generally done to verify the static analysis. In this work, a model crib construction (1:20) made of bamboo elements is tested in the centrifuge machine to determine the strength behaviour of the slope supported by vegetated crib retaining wall. A geotechnical centrifuge is used to conduct model tests to study geotechnical problems such as the strength, stiffness and bearing capacity of different structures, settlement of embankments, stability of slopes, earth retaining structures etc. Centrifuge model testing is particularly well suited to modelling geotechnical events because the increase in gravitational force creates stresses in the model that are equivalent to the much larger prototype and hence ensures that the mechanisms of ground movements observed in the tests are realistic. Centrifuge model testing provides data to improve our understanding of basic mechanisms

  16. The Construction of a Muscular Strength Test Battery for Girls in the Primary Grades.

    Science.gov (United States)

    DiNucci, James M.; Pelton, Elois B.

    This study was designed to construct a gross muscular strength test battery for girls 6-9 years of age in grades 1-3. The subjects for this investigation were a random sample of 183 girls in grades 1-3 of the public schools of Natchitoches, Louisiana. The variables selected were 22 cable tension strength tests developed by Clarke and associates.…

  17. Strength Assessment of Controlled Low Strength Materials (CLSM) Utilizing Recycled Concrete Aggregate and Waste Paper Sludge Ash

    OpenAIRE

    Ridzuan, Ahmad Ruslan Mohd; Fauzi, Mohd Azrizal; Ghazali, Ezliana; Arshad, Mohd Fadzil; Fauzi, Mohd Afiq; Mohd Fauzi, Mohd Afiq

    2013-01-01

    This paper studies the strength development of low-strength material (CLSM) is controlled by using waste paper sludge ash (WPSA) in CLSM mixtures without adding Portland cement. Series of four (4) compounds which is the CLSM containing 5%, 10%, 20% and 30% of waste paper sludge ash (WPSA) as a substitute for Portland cement. CLSM cubes the sizes of 100mm x 100mm x 100mm compressive strength were tested at age 7, 14 and 28days. It was found that this activity contributes to strength developmen...

  18. COMPARISON OF RANGE OF MOTION, STRENGTH, AND HOP TEST PERFORMANCE OF DANCERS WITH AND WITHOUT A CLINICAL DIAGNOSIS OF FEMOROACETABULAR IMPINGEMENT.

    Science.gov (United States)

    Kivlan, Benjamin R; Carcia, Christopher R; Christoforetti, John J; Martin, RobRoy L

    2016-08-01

    Dancers commonly experience anterior hip pain caused by femoroacetabular impingement (FAI) that interrupts training and performance in dance. A paucity of literature exists to guide appropriate evaluation and management of FAI among dancers. The purpose of this study was to determine if dancers with clinical signs of FAI have differences in hip range of motion, strength, and hop test performance compared to healthy dancers. Quasi-experimental, cohort comparison. Fifteen dancers aged between 18- 21 years with clinical signs of FAI that included anterior hip pain and provocative impingement tests were compared to 13 age-matched dancers for passive hip joint range of motion, isometric hip strength, and performance of the medial triple hop, lateral triple hop, and cross-over hop tests. No statistically significant differences in range of motion were noted for flexion (Healthy = 145° + 7°; FAI = 147° + 10°; p=0.59), internal rotation (Healthy = 63° + 7°; FAI = 61° + 11°; p=0.50), and external rotation (Healthy = 37° + 9°; FAI = 34° + 12°; p=0.68) between the two groups. Hip extension strength was significantly less in the dancers with FAI (224 + 55 Newtons) compared to the healthy group (293 ± 58 Newtons; F(1,26) = 10.2; p=0.004). No statistically significant differences were noted for flexion, internal rotation, external rotation, abduction, or adduction isometric strength. The medial triple hop test was significantly less in the FAI group (354 ± 43 cm) compared to the healthy group (410 ± 50 cm; F(1,26) = 10.3; p = 0.004). Similar results were observed for the lateral hop test, as the FAI group (294 ± 38 cm) performed worse than the healthy controls (344 ± 54cm; F(1,26) = 7.8; p = 0.01). There was no statistically significant difference between the FAI group (2.7 ± 0.92 seconds) and the healthy group (2.5 ± 0.75 seconds) on the crossover hop

  19. Influence of Specimen Preparation and Test Methods on the Flexural Strength Results of Monolithic Zirconia Materials.

    Science.gov (United States)

    Schatz, Christine; Strickstrock, Monika; Roos, Malgorzata; Edelhoff, Daniel; Eichberger, Marlis; Zylla, Isabella-Maria; Stawarczyk, Bogna

    2016-03-09

    The aim of this work was to evaluate the influence of specimen preparation and test method on the flexural strength results of monolithic zirconia. Different monolithic zirconia materials (Ceramill Zolid (Amann Girrbach, Koblach, Austria), Zenostar ZrTranslucent (Wieland Dental, Pforzheim, Germany), and DD Bio zx² (Dental Direkt, Spenge, Germany)) were tested with three different methods: 3-point, 4-point, and biaxial flexural strength. Additionally, different specimen preparation methods were applied: either dry polishing before sintering or wet polishing after sintering. Each subgroup included 40 specimens. The surface roughness was assessed using scanning electron microscopy (SEM) and a profilometer whereas monoclinic phase transformation was investigated with X-ray diffraction. The data were analyzed using a three-way Analysis of Variance (ANOVA) with respect to the three factors: zirconia, specimen preparation, and test method. One-way ANOVA was conducted for the test method and zirconia factors within the combination of two other factors. A 2-parameter Weibull distribution assumption was applied to analyze the reliability under different testing conditions. In general, values measured using the 4-point test method presented the lowest flexural strength values. The flexural strength findings can be grouped in the following order: 4-point strength values than prepared before sintering. The Weibull moduli ranged from 5.1 to 16.5. Specimens polished before sintering showed higher surface roughness values than specimens polished after sintering. In contrast, no strong impact of the polishing procedures on the monoclinic surface layer was observed. No impact of zirconia material on flexural strength was found. The test method and the preparation method significantly influenced the flexural strength values.

  20. A curved beam test specimen for determining the interlaminar tensile strength of a laminated composite

    Science.gov (United States)

    Hiel, Clement C.; Sumich, Mark; Chappell, David P.

    1991-01-01

    A curved beam type of test specimen is evaluated for use in determining the through-the-thickness strength of laminated composites. Two variations of a curved beam specimen configuration (semicircular and elliptical) were tested to failure using static and fatigue loads. The static failure load for the semicircular specimens was found to be highly sensitive to flaw content, with the specimens falling into two distinct groups. This result supports the use of proof testing for structural validation. Static design allowables are derived based on the Weibull distribution. Fatigue data indicates no measured increase in specimen compliance prior to final fracture. All static and fatigue failures at room temperature dry conditions occurred catastrophically. The elliptical specimens demonstrated unusually high failure strengths indicating the presence of phenomena requiring further study. Results are also included for specimens exposed to a wet environment showing a matrix strength degradation due to moisture content. Further testing is underway to evaluate a fatigue methodology for matrix dominated failures based on residual static strength (wearout).

  1. Workability and Compressive Strength for Concrete With Coconut Shell Aggregate

    Directory of Open Access Journals (Sweden)

    Leman Alif Syazani

    2017-01-01

    Full Text Available This study was conducted to investigate the compressive strength and workability of concrete added with coconut shells. Comparisons were made between conventional concrete with concrete mix coconut shell. In this study, the concretes were mixes with coconut shell by percentage of weight concrete which is 0%, 5%, and 10%. The coconut shell has been crushed first, then it was sieved, to get the optimum size which, that retained on the 5mm sieve and passing 10mm sieve. Experimental tests conducted in this study are slump test and compressive test. The results from this study are workability of concrete added with 0% and 5% of coconut shell has medium degree of workability compared to concrete added with 10% that has low workability. For the compressive strength, the concrete added with 5% and 10% of coconut shell has lower strength compared with normal concrete.

  2. The tensile strength test of thermoplastic materials based on poly(butylene terephtalate

    Directory of Open Access Journals (Sweden)

    Rzepecka Anna

    2017-01-01

    Full Text Available Thermoplastic composites go toward making an increasingly greater percentage of all manufacturing polymer composites. They have a lot of beneficial properties and their manufacturing using injecting and extrusion methods is a very easy and cheap process. Their properties significantly overtake the properties of traditional materials and it is the reason for their use. Scientists are continuously carrying out research to find new applications of composites materials in new industries, not only in the automotive or aircraft industry. When thermoplastic composites are manufactured a very important factor is the appropriate accommodation of tensile strength to their predestination. Scientists need to know the behaviour of these materials during the impact of different forces, and the factors of working in normal conditions too. The main aim of this article was macroscopic and microscopic analysis of the structure of thermoplastic composites after static tensile strength test. Materials which were analysed were thermoplastic materials which have poly(butylene terephthalate – PBT matrix reinforced with different content glass fibres – from 10% for 30%. In addition, research showed the necessary force to receive fracture and set their distinguishing characteristic down.

  3. Bleed water testing program for controlled low strength material

    International Nuclear Information System (INIS)

    Langton, C.A.

    1996-01-01

    Bleed water measurements for two Controlled Low Strength Material (CLSM) mixes were conducted to provide engineering data for the Tank 20F closure activities. CLSM Mix 1 contained 150 pounds of cement per cubic yard whereas CLSM Mix 2 contained 50 pounds per cub yard. SRS currently used CLSM Mix 2 for various applications. Bleed water percentages and generation rates were measured along with flow and compressive strength. This information will be used to select a mix design for the Tank 20F closure activities and to establish the engineering requirements, such as, lift height, time required between lifts and quantity of bleed water to be removed from the tank during the placement activities. Mix 1 is recommended for placement within Tank 20F because it has better flow characteristics, less segregation, lower percentage of bleed water and slightly higher strength. Optimization of Mix 1 was beyond the scope of this study. However, further testing of thickening additives, such as clays (bentonite), sodium silicate or fine silicas maybe useful for decreasing or eliminating bleed water

  4. Changes in muscle strength in patients with statin myalgia.

    Science.gov (United States)

    Panza, Gregory A; Taylor, Beth A; Roman, William; Thompson, Paul D

    2014-10-15

    Statins can produce myalgia or muscle pain, which may affect medication adherence. We measured the effects of statins on muscle strength in patients with previous statin myalgia. Leg isokinetic extension average power at 60° per second (-8.8 ± 10.5N-M, p = 0.02) and average peak torque at 60° per second (-14.0 ± 19.7N-M, p = 0.04) decreased slightly with statin use, but 8 of 10 other variables for leg strength did not change (all p >0.13). Handgrip, muscle pain, respiratory exchange ratio, and daily activity also did not change (all p >0.09). In conclusion, statin myalgia is not associated with reduced muscle strength or muscle performance. Published by Elsevier Inc.

  5. Isometric muscle strength and mobility capacity in children with cerebral palsy.

    Science.gov (United States)

    Dallmeijer, Annet J; Rameckers, Eugene A; Houdijk, Han; de Groot, Sonja; Scholtes, Vanessa A; Becher, Jules G

    2017-01-01

    To determine the relationship between isometric leg muscle strength and mobility capacity in children with cerebral palsy (CP) compared to typically developing (TD) peers. Participants were 62 children with CP (6-13 years), able to walk with (n = 10) or without (n = 52) walking aids, and 47 TD children. Isometric muscle strength of five muscle groups of the leg was measured using hand-held dynamometry. Mobility capacity was assessed with the 1-min walk, the 10-m walk, sit-to-stand, lateral-step-up and timed-stair tests. Isometric strength of children with CP was reduced to 36-82% of TD. When adjusted for age and height, the percentage of variance in mobility capacity that was explained by isometric strength of the leg muscles was 21-24% (walking speed), 25% (sit-to-stand), 28% (lateral-step-up) and 35% (timed-stair) in children with CP. Hip abductors and knee flexors had the largest contribution to the explained variance, while knee extensors showed the weakest correlation. Weak or no associations were found between strength and mobility capacity in TD children. Isometric strength, especially hip abductor and knee flexor strength, is moderately related to mobility capacity in children with CP, but not in TD children. To what extent training of these muscle groups will lead to better mobility capacity needs further study. Implications for Rehabilitation Strength training in children with cerebral palsy (CP) may be targeted more specifically at hip abductors and knee flexors. The moderate associations imply that large improvements in mobility capacity may not be expected when strength increases.

  6. Study on strength of thick reinforced concrete slab with opening - Part 2: Evaluation of the test results

    International Nuclear Information System (INIS)

    Hirai, T.; Itoh, M.; Takei, K.; Kanazu, T.; Abe, Y.; Takahashi, T.; Hayashi, N.; Sasaki, N.

    1993-01-01

    In comparing the strength of the partial models obtained from the test and the strength calculated by the various formulas for short span cantilevers based on recent research, it was found that the strength of the partial models coincided well with the calculated bending strength. It was confirmed that bending failure also preceded in the overall model from the tests. However various strengths such as the cracking strength and the yielding strength of rebars were larger, and displacements and strains in various parts were smaller than those in the partial models. It was attributed to the effects of circumferential distribution of the load. A convenient method was proposed for evaluation of the strength of the overall model. In this method, the overall model is divided into corbels, and the strength of the model is calculated as the sum of these corbels' strength. This method estimated the strength conveniently and conservatively. (author)

  7. ON THE 10 μm SILICATE FEATURE IN ACTIVE GALACTIC NUCLEI

    International Nuclear Information System (INIS)

    Nikutta, Robert; Elitzur, Moshe; Lacy, Mark

    2009-01-01

    The 10 μm silicate feature observed with Spitzer in active galactic nuclei (AGNs) reveals some puzzling behavior. It (1) has been detected in emission in type 2 sources, (2) shows broad, flat-topped emission peaks shifted toward long wavelengths in several type 1 sources, and (3) is not seen in deep absorption in any source observed so far. We solve all three puzzles with our clumpy dust radiative transfer formalism. Addressing (1), we present the spectral energy distribution (SED) of SST1721+6012, the first type 2 quasar observed to show a clear 10 μm silicate feature in emission. Such emission arises in models of the AGN torus easily when its clumpy nature is taken into account. We constructed a large database of clumpy torus models and performed extensive fitting of the observed SED. We find that the cloud radial distribution varies as r -1.5 and the torus contains 2-4 clouds along radial equatorial rays, each with optical depth at visual ∼60-80. The source bolometric luminosity is ∼3 x 10 12 L sun . Our modeling suggests that ∼<35% of objects with tori sharing these characteristics and geometry would have their central engines obscured. This relatively low obscuration probability can explain the clear appearance of the 10 μm emission feature in SST1721+6012 together with its rarity among other QSO2. Investigating (2), we also fitted the SED of PG1211+143, one of the first type 1 QSOs with a 10 μm silicate feature detected in emission. Together with other similar sources, this QSO appears to display an unusually broadened feature whose peak is shifted toward longer wavelengths. Although this led to suggestions of non-standard dust chemistry in these sources, our analysis fits such SEDs with standard galactic dust; the apparent peak shifts arise from simple radiative transfer effects. Regarding (3), we find additionally that the distribution of silicate feature strengths among clumpy torus models closely resembles the observed distribution, and the

  8. Adhesion strength of Ni film on Ti substrate characterized by three-point bend test, peel test and theoretic calculation

    International Nuclear Information System (INIS)

    Ren, F.Z.; Liu, P.; Jia, S.G.; Tian, B.H.; Su, J.H.

    2006-01-01

    Electroplating was employed to fabricate the Ni film on the Ti substrate. Adhesion strength of Ni film on Ti substrate was determined using the three-point bend technique that was proposed in standard mechanics test. The experimental results demonstrate that the interface fracture energies obviously increase with the roughness of Ti substrates, and are independence with the thickness of Ni films. Moreover, the adhesion strength of Ni film on Ti substrate was also measured by peel test, and was evaluated by Miedema model of experiential electron theory. The intrinsic interface fracture energy measured by three-point bend test is reasonable agreement with that obtained by theoretical calculation of Miedema model, and is roughly comparable to that by peel test

  9. Effect of test temperature on the fatigue strength of the 12GN2MFAYu tempered steel

    International Nuclear Information System (INIS)

    Goritskij, V.M.; Terent'ev, V.F.; Bobyleva, L.A.

    1979-01-01

    The cyclic strength, variation of dislocation structure and fractography of specimen fractures were investigated depending on testing temperature. The specimens were tested at temperatures of 20, 350, 450, 550 deg C. The increase of testing temperature, according to the experimental data obtained, is accompanied by an insignificant reduction of fatigue strength. The testing temperature in the range from 350 to 550 deg C has a weak effect on the fatigue strength of the quenched and tempered steel. A change in the dislocation structure occurs under all tested temperatures in the 12 GN2MFAYu steel during fatigue. The intensity of the rearrangement of dislocation structure increases as the testing temperature increases to 550 deg C causing a decrease of the limited life-time at increased stress amplitudes

  10. The Effect of Sodium Hydroxide Molarity on Strength Development of Non-Cement Class C Fly Ash Geopolymer Mortar

    Science.gov (United States)

    Wardhono, A.

    2018-01-01

    The use of fly ash as cement replacement material can overcome the environmental issues, especially the global warming problem caused by the greenhouse effect. This is attributed to the CO2 gas produced during the cement manufacturing process, which 1 ton of cement is equivalent to 1 ton CO2. However, the major problem of fly ash is the requirement of activators to activate the polymer reactions. The most common activator used in non-cement or geopolymer material is the combination of sodium hydroxide (NaOH) and sodium silicate. This study aims to identify the effect of NaOH molarity as activator on strength development of non-cement class C fly ash geopolymer mortar. The molarity variations of NaOH were 6 Molar (M), 8M, 10M, 12M, 14M and 15M. The compressive strength test was performed at the age of 3, 7 and 28 days in accordance with ASTM standard, and the specimens were cured at room temperature. The results show that the highest compressive strength was achieved by geopolymer mortar with a molarity of 12M. It exhibits a higher strength to that normal mortar at 28 days. However, the use of NaOH molarity more than 12M tends to decrease the strength of non-cement geopolymer mortar specimens.

  11. Influence of different adhesive systems on the pull-out bond strength of glass fiber posts.

    Science.gov (United States)

    da Silva, Luciana Mendonça; Andrade, Andréa Mello de; Machuca, Melissa Fernanda Garcia; da Silva, Paulo Maurício Batista; da Silva, Ricardo Virgolino C; Veronezi, Maria Cecília

    2008-01-01

    This in vitro study evaluated the tensile bond strength of glass fiber posts (Reforpost - Angelus-Brazil) cemented to root dentin with a resin cement (RelyX ARC - 3M/ESPE) associated with two different adhesive systems (Adper Single Bond - 3M/ESPE and Adper Scotchbond Multi Purpose (MP) Plus - 3M/ESPE), using the pull-out test. Twenty single-rooted human teeth with standardized root canals were randomly assigned to 2 groups (n=10): G1- etching with 37% phosphoric acid gel (3M/ESPE) + Adper Single Bond + #1 post (Reforpost - Angelus) + four #1 accessory posts (Reforpin - Angelus) + resin cement; G2- etching with 37% phosphoric acid gel + Adper Scotchbond MP Plus + #1 post + four #1 accessory posts + resin cement. The specimens were stored in distilled water at 37 degrees C for 7 days and submitted to the pull-out test in a universal testing machine (EMIC) at a crosshead speed of 0.5 mm/min. The mean values of bond strength (kgf) and standard deviation were: G1- 29.163 +/- 7.123; G2- 37.752 +/-13.054. Statistical analysis (Student's t-test; a=0.05 showed no statistically significant difference (pAdhesive bonding failures between resin cement and root canal dentin surface were observed in both groups, with non-polymerized resin cement in the apical portion of the post space when Single Bond was used (G1). The type of adhesive system employed on the fiber post cementation did not influence the pull-out bond strength.

  12. Influence of different adhesive systems on the pull-out bond strength of glass fiber posts

    Directory of Open Access Journals (Sweden)

    Luciana Mendonça da Silva

    2008-06-01

    Full Text Available This in vitro study evaluated the tensile bond strength of glass fiber posts (Reforpost - Angelus-Brazil cemented to root dentin with a resin cement (RelyX ARC - 3M/ESPE associated with two different adhesive systems (Adper Single Bond - 3M/ESPE and Adper Scotchbond Multi Purpose (MP Plus - 3M/ESPE, using the pull-out test. Twenty single-rooted human teeth with standardized root canals were randomly assigned to 2 groups (n=10: G1- etching with 37% phosphoric acid gel (3M/ESPE + Adper Single Bond + #1 post (Reforpost - Angelus + four #1 accessory posts (Reforpin - Angelus + resin cement; G2- etching with 37% phosphoric acid gel + Adper Scotchbond MP Plus + #1 post + four #1 accessory posts + resin cement. The specimens were stored in distilled water at 37°C for 7 days and submitted to the pull-out test in a universal testing machine (EMIC at a crosshead speed of 0.5 mm/min. The mean values of bond strength (kgf and standard deviation were: G1- 29.163 ± 7.123; G2- 37.752 ±13.054. Statistical analysis (Student's t-test; a=0.05 showed no statistically significant difference (p<0.05 between the groups. Adhesive bonding failures between resin cement and root canal dentin surface were observed in both groups, with non-polymerized resin cement in the apical portion of the post space when Single Bond was used (G1. The type of adhesive system employed on the fiber post cementation did not influence the pull-out bond strength.

  13. Handgrip strength shows no improvements in geriatric patients with persistent inflammation during hospitalization

    DEFF Research Database (Denmark)

    Norheim, Kristoffer Larsen; Bautmans, Ivan; Kjaer, Michael

    2017-01-01

    PURPOSE: Hospital-associated deconditioning due to a combination of illness and inactivity is a serious problem for elderly adults. Here we investigate whether persistence in inflammatory status affects changes in physical function during short-term hospitalization. METHODS: This was a prospective...... observational study in elderly medical patients at a geriatric department. Measurements were obtained at admission and one week after admission and included de Morton Mobility Index (DEMMI) test, 30-second chair stand test (30-s CST), 4-m gait speed (4-m GST) test, handgrip strength, activity levels determined...... with ActivPALs, and concentrations of circulating C-reactive protein (CRP) from blood samples. Only patients with inflammation (C-reactive protein levels ≥10mg·L(-1)) at admission were included in this study. They were divided into those with continued inflammation (CI: CRP remained ≥10mg·L(-1)) and those...

  14. Experimental study on the properties of drum-packed, cement solidified waste package of pre and after sea dumping test of sea depth 30m and 100m

    International Nuclear Information System (INIS)

    Maki, Yasuro; Abe, Hirotoshi; Hattori, Seiichi

    1976-01-01

    Japan Marine Science and Technology Center has been tackling with the development of the monitoring system to confirm the soundness of drum-packed, cement-solidified low level radioactive waste (the package) during falling and after reaching at sea bed when it is dumped into sea. The test was carried out at Sagami Bay of 30 m and 100 m sea depth using non-radioactive packages. The observation of the falling behaviour of packages in sea was carried out by taking photographs of the motion of packages with an underwater 16 mm movie camera and an underwater industrial TV (ITV), and the observation of the soundness and the area of packages scattered on sea bed was carried out with an underwater ITV and an underwater 70 mm snap camera which were set up on the frame. The proportion of cement-solidified waste was decided so that the uni-axial compressive strength of the cement-solidified waste satisfies the condition of ''The tentative guideline''. Prior to tests at sea, hydrostatic pressure test of packages are carried out on land. After that, core specimens were sampled to obtain the uniaxial compressive strength from packages and were tested. After sea dumping tests, 6 packages were recovered from sea bed, and the soundness were tested. As the results, the deformation and damage of drums and cement solidified waste packages did not occur at all. (Kako, I.)

  15. Tests for determining impact resistance and strength of glass used for nuclear waste disposal

    International Nuclear Information System (INIS)

    Bunnell, L.R.

    1979-05-01

    Tests are described for determining the impact resistance (Section A) and static tensile strength (Section B) of glasses containing simulated or actual nuclear wastes. This report describes the development and use of these tests to rank different glasses, to assess effects of devitrification, and to examine the effect of impact energy on resulting surface area. For clarity this report is divided into two sections, Impact Resistance and Tensile Strength

  16. Effect of test temperature and strain rate on the tensile properties of high-strength, high-conductivity copper alloys

    Energy Technology Data Exchange (ETDEWEB)

    Zinkle, S.J.; Eatherly, W.S. [Oak Ridge National Lab., TN (United States)

    1997-04-01

    The unirradiated tensile properties of wrought GlidCop AL25 (ITER grade zero, IGO) solutionized and aged CuCrZr, and cold-worked and aged and solutionized and aged Hycon 3HP{trademark} CuNiBe have been measured over the temperature range of 20-500{degrees}C at strain rates between 4 x 10{sup {minus}4} s{sup {minus}1} and 0.06 s{sup {minus}1}. The measured room temperature electrical conductivity ranged from 64 to 90% IACS for the different alloys. All of the alloys were relatively insensitive to strain rate at room temperature, but the strain rate sensitivity of GlidCop Al25 increased significantly with increasing temperature. The CuNiBe alloys exhibited the best combination of high strength and high conductivity at room temperature. The strength of CuNiBe decreased slowly with increasing temperature. However, the ductility of CuNiBe decreased rapidly with increasing temperature due to localized deformation near grain boundaries, making these alloy heats unsuitable for typical structural applications above 300{degrees}C. The strength and uniform elongation of GlidCop Al25 decreased significantly with increasing temperature at a strain rate of 1 x 10{sup {minus}3} s{sup {minus}1}, whereas the total elongation was independent of test temperature. The strength and ductility of CuCrZr decreased slowly with increasing temperature.

  17. Establishment of an indirect ELISA for detection of the novel antifibrotic peptide M10.

    Directory of Open Access Journals (Sweden)

    Tanjina Akter

    Full Text Available M10 is a ten amino acid peptide generated from the intracellular cytoplasmic tail of the hepatocyte growth factor (HGF receptor c-Met following cleavage by caspase-3. Recently we reported that M10 interacts with Smad2 and demonstrates antifibrotic properties in vitro and in vivo and can be advanced into a novel antifibrotic remedy. The current study was undertaken to develop an immunoassay to measure M10 concentration in biological specimens.An Indirect Enzyme-Linked Immunosorbent Assay (ELISA for detection of M10 in biological fluids was developed using pharmaceutical grade synthetic M10 as a calibrator and commercially available anti-c-Met C12 antibody.M10 ELISA specifically detected in plasma M10, but not a scrambled peptide, following a single intraperitoneal administration of M10 (1mg/kg to mice. The detection limit was 9.6 ng/ml, and the measuring limit was between 15 ng/ml and 200 ng/ml. The recovery limits of M10 were between 80% and 120%; intra-assay coefficient of variation was between 5.3% and 6.3%; inter-assay coefficient of variation was between 5.0% and 8.0% over the buffer concentration tested in the range from 15 ng /ml to 250 ng /ml. The peak of M10 concentration following a single intraperitoneal injection (1mg/kg was achieved within 6 hours and declined to minimal levels by 48 hours. The experimentally obtained half-life for M10 was comparable to the theoretically predicted half-life for M10.We have established a highly sensitive ELISA to detect the antifibrotic peptide M10 in plasma samples, which should prove to be a novel tool to study the pharmacokinetics and efficacy of M10 in the treatment of fibroproliferative disorders.

  18. Electromyography Activation Levels of the 3 Gluteus Medius Subdivisions During Manual Strength Testing

    DEFF Research Database (Denmark)

    Otten, Roald; Tol, Johannes L; Holmich, Per

    2015-01-01

    deficits and guide specific rehabilitation programs. However, the optimal positions for assessing the strength and activation of these subdivisions are unknown. OBJECTIVE: The first aim was to establish which strength-testing positions produce the highest surface electromyography (sEMG) activation levels...... of the individual GM subdivisions. The second aim was to evaluate differences in sEMG activation levels between the tested and contralateral (stabilizing) leg. METHOD: Twenty healthy physically active male subjects participated in this study. Muscle activity using sEMG was recorded for the GM subdivisions in 8......STUDY DESIGN: Cross-sectional. CONTEXT: Gluteus medius (GM) muscle dysfunction is associated with overuse injury. The GM is functionally composed of 3 separate subdivisions: anterior, middle, and posterior. Clinical assessment of the GM subdivisions is relevant to detect strength and activation...

  19. Stochastic models for strength of wind turbine blades using tests

    DEFF Research Database (Denmark)

    Toft, H.S.; Sørensen, John Dalsgaard

    2008-01-01

    The structural cost of wind turbine blades is dependent on the values of the partial safety factors which reflect the uncertainties in the design values, including statistical uncertainty from a limited number of tests. This paper presents a probabilistic model for ultimate and fatigue strength...... of wind turbine blades especially considering the influence of prior knowledge and test results and how partial safety factors can be updated when additional full-scale tests are performed. This updating is performed by adopting a probabilistic design basis based on Bayesian statistical methods....

  20. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics

    Science.gov (United States)

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-01-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen’s size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics. PMID:26816646

  1. Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics.

    Science.gov (United States)

    Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan

    2015-12-01

    Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen's size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics.

  2. The effect of double-row fixation on initial repair strength in rotator cuff repair: a biomechanical study.

    Science.gov (United States)

    Meier, Steven W; Meier, Jeffrey D

    2006-11-01

    The purpose of this study was to compare the initial mechanical strength of 3 rotator cuff repair techniques. A total of 30 fresh-frozen cadaveric shoulders were prepared, and full-thickness supraspinatus tears were created. Specimens were randomized and placed into 3 groups: (1) transosseous suture technique (group I: TOS, n = 10, 6F/4M), (2) single-row suture anchor fixation (group II: SRSA, n = 10, 6F/4M), and (3) double-row suture anchor fixation (group III: DRSA, n = 10, 6F/4M). Each specimen underwent cyclic load testing from 5 N to 180 N at a rate of 33 mm/sec. The test was stopped when complete failure (repair site gap of 10 mm) or a total of 5,000 cycles was attained. Group I (TOS) failed at an average of 75.3 +/- 22.49 cycles, and group II (SRSA) at an average of 798.3 +/- 73.28 cycles; group III (DRSA) had no failures because all samples were stopped when 5,000 cycles had been completed. Fixation strength of the DRSA technique proved to be significantly greater than that of SRSA (P row suture anchor fixation was significantly stronger than was single-row repair. Therefore, double-row fixation may be superior to other techniques in that it provides a substantially stronger repair that could lead to improved biologic healing. A high incidence of incomplete healing occurs in rotator cuff repair. Use of double-row fixation may help the clinician to address some deficiencies in current methods by increasing the strength of the repair, potentially leading to improved healing rates.

  3. Design and production of a novel sand materials strength testing machine for foundry applications

    DEFF Research Database (Denmark)

    Nwaogu, Ugochukwu Chibuzoh; Hansen, K. S.; Tiedje, Niels Skat

    2012-01-01

    testing machine was designed and built for both green sand and chemically-bonded sand materials. This machine measures and presents the loading response as a force-displacement profile from which the mechanical properties of the moulding materials can be deduced. The system was interfaced to a computer......In the foundry, existing strength testing machines are used to measure only the maximum fracture strength of mould and core materials. With traditionally used methods, the loading history to ascertain deformation of the material is not available. In this paper, a novel moulding material strength...... with a commercial PC based-control and data acquisition software. The testing conditions and operations are specified in the user interface and the data acquisition is made according to specifications. The force and displacements were calibrated to ensure consistency and reliability of the measurement data...

  4. Four-Point Bending Strength Testing of Pultruded Fiberglass Composite Wind Turbine Blade Sections

    International Nuclear Information System (INIS)

    Musial, W.; Bourne, B; Hughes, S; Zuteck, M. D.

    2001-01-01

    The ultimate strength of the PS Enterprises pultruded blade section was experimentally determined under four-point bending at the National Renewable Energy Laboratory. Thirteen 8-foot long full-scale blade segments were individually tested to determine their maximum moment carrying capability. Three airfoil-bending configurations were tested: high- and low-pressure skin buckling, and low pressure skin buckling with foam interior reinforcement. Maximum strain was recorded for each sample on the compressive and tensile surfaces of each test blade. Test data are compared to the results of three analytical buckling prediction methods. Based on deviations from the linear strain versus load curve, data indicate a post-buckling region. High-pressure side buckling occurred sooner than low-pressure side buckling. The buckling analyses were conservative for both configurations, but high-pressure side buckling in particular was substantially under-predicted. Both high- and low-pressure buckling configurations had very similar failure loads. These results suggests that a redundant load path may be providing strength to the section in the post-buckling region, making the onset of panel buckling a poor predictor of ultimate strength for the PS Enterprises pultrusion

  5. The effect of different light-curing units on tensile strength and microhardness of a composite resin

    Directory of Open Access Journals (Sweden)

    Eduardo Batista Franco

    2007-12-01

    Full Text Available The aim of this study was to evaluate the influence of different light-curing units on the tensile bond strength and microhardness of a composite resin (Filtek Z250 - 3M/ESPE. Conventional halogen (Curing Light 2500 - 3M/ESPE; CL and two blue light emitting diode curing units (Ultraled - Dabi/Atlante; UL; Ultrablue IS - DMC; UB3 and UB6 were selected for this study. Different light intensities (670, 130, 300, and 600 mW/cm², respectively and different curing times (20s, 40s and 60s were evaluated. Knoop microhardness test was performed in the area corresponding to the fractured region of the specimen. A total of 12 groups (n=10 were established and the specimens were prepared using a stainless steel mold composed by two similar parts that contained a cone-shaped hole with two diameters (8.0 mm and 5.0 mm and thickness of 1.0 mm. Next, the specimens were loaded in tensile strength until fracture in a universal testing machine at a crosshead speed of 0.5 mm/min and a 50 kg load cell. For the microhardness test, the same matrix was used to fabricate the specimens (12 groups; n=5. Microhardness was determined on the surfaces that were not exposed to the light source, using a Shimadzu HMV-2 Microhardness Tester at a static load of 50 g for 30 seconds. Data were analyzed statistically by two-way ANOVA and Tukey's test (p<0.05. Regarding the individual performance of the light-curing units, there was similarity in tensile strength with 20-s and 40-s exposure times and higher tensile strength when a 60-s light-activation time was used. Regarding microhardness, the halogen lamp had higher results when compared to the LED units. For all light-curing units, the variation of light-exposure time did not affect composite microhardness. However, lower irradiances needed longer light-activation times to produce similar effect as that obtained with high-irradiance light-curing sources.

  6. Compressive strength test for cemented waste forms: validation process

    International Nuclear Information System (INIS)

    Haucz, Maria Judite A.; Candido, Francisco Donizete; Seles, Sandro Rogerio

    2007-01-01

    In the Cementation Laboratory (LABCIM), of the Development Centre of the Nuclear Technology (CNEN/CDTN-MG), hazardous/radioactive wastes are incorporated in cement, to transform them into monolithic products, preventing or minimizing the contaminant release to the environment. The compressive strength test is important to evaluate the cemented product quality, in which it is determined the compression load necessary to rupture the cemented waste form. In LABCIM a specific procedure was developed to determine the compressive strength of cement waste forms based on the Brazilian Standard NBR 7215. The accreditation of this procedure is essential to assure reproductive and accurate results in the evaluation of these products. To achieve this goal the Laboratory personal implemented technical and administrative improvements in accordance with the NBR ISO/IEC 17025 standard 'General requirements for the competence of testing and calibration laboratories'. As the developed procedure was not a standard one the norm ISO/IEC 17025 requests its validation. There are some methodologies to do that. In this paper it is described the current status of the accreditation project, especially the validation process of the referred procedure and its results. (author)

  7. Strength of vacuum brazed joints for repair; Haallfasthet hos reparationer utfoerda med vakuumloedning

    Energy Technology Data Exchange (ETDEWEB)

    Berglin, Leif [Siemens Industrial Turbomachinery AB, Finspaang (Sweden)

    2005-04-01

    Strength data are missing for braze joints. Repaired components cannot fully make use of the strength of the braze, and lifetime will be underestimated. The goal of the project was to generate material data to be able to prolong the lifetime of the components. Two different material combinations were tested, 12% Chromium steel brazed with BNi-2, and a nickel base alloy, IN792 brazed with BNi-5. Tensile testing at room temperature and elevated temperature was performed in the project. Target group is purchasers and suppliers of repaired components. A tensile test specimen with butt joint was developed in the project. The used test specimen worked well for the 12% Chromium steel. The results from testing show that proof stress and tensile strength are strongly depending on the joint gap, particularly at room temperature. High strength, close to base material strength, was achieved with joint gaps smaller than 50{mu}m. For wider joint gaps, strength was lower. Strength was approximately 25% of base material strength for joint gaps over 100{mu}m. The results can be explained by changes in microstructure. Joint gaps wider than 50{mu}m showed evidence of two-phase structure. At 500 deg C, the results also showed a connection between joint gap, microstructure and strength. The generated strength data can be used for calculations of lifetime for repaired components. Two different process errors were discovered in the manufacturing process of the brazed IN792 test specimens. The generated material data are therefor erroneous. The reason for this was two manufacturing errors. The tack welding was done with too high heat input. The surfaces of the joint gap became oxidised and the oxide hindered wetting of the braze. The second reason was that the brazing was done without the prescribed hold time at maximum temperature. The melting of the braze was therefor not completed when cooling started. As a result, the strength of the IN792 specimens was low at both temperatures.

  8. Effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin

    Directory of Open Access Journals (Sweden)

    Payal Singh

    2017-07-01

    Full Text Available Objectives This in vitro study evaluated the effect of dentin biomodifiers on the immediate and long-term bond strengths of a simplified etch and rinse adhesive to dentin. Materials and Methods Flat coronal dentin surfaces were prepared in 120 extracted human molars. Teeth were randomly divided into 5 groups (n = 24 according to 5 different surface pre-treatments: No pre-treatment (control; 1M carbodiimide (EDC; 0.1% epigallocatechin-3-gallate (EGCG; 2% minocycline (MI; 10% sodium ascorbate (SA. After surface pre-treatment, adhesive (Adper Single Bond 2 [SB], 3M ESPE was applied. Composite was applied into transparent plastic tubes (2.5 mm in diameter, which was placed over the bonded dentin surface. From each group, 10 samples were subjected to shear bond strength (SBS evaluation at 24 hours (immediate and remaining 10 samples were tested after 6 months (delayed. Additionally, 4 samples per group were subjected to scanning electron microscopic analysis for observation of resin-dentin interface. The data were statistically analysed with Shaperio‑Wilk W test, 2-way analysis of variance (ANOVA, and post hoc Tukey's test. Results At 24 hours, SBS of all surface pre-treatment groups were comparable with the control group, with significant differences found between EDC and SA groups only (p = 0.009. After 6 months storage, EDC, EGCG, and MI pre-treatments preserved the resin-dentin bond strength with no significant fall. Conclusions Dentin pre-treatment with all the dentin biomodifiers except SA resulted in significant preservation of resin-dentin bond over 6 months storage period, without negatively affecting the immediate bond strength of the etch and rinse adhesive tested.

  9. The relation between knee muscle strength and performance tests in orienteering athletes.

    Science.gov (United States)

    Çinar-Medeni, Özge; Colakoglu, Fatma F; Yüce, Koray; Ipekoğlu, Gökhan; Baltaci, Gul

    2016-11-01

    The aim of this study was to analyze the effect of knee muscle strength on performance tests in orienteers. Thirty-seven orienteers were voluntarily included in this study. Isokinetic knee flexor and extensor muscles' strength was assessed at 120°/s velocity for both "dominant leg" (DL) and "non-dominant leg" (NDL). "Single-legged hop test" (SLHT), "flamingo balance test" (FBT), "star excursion balance test" (SEBT), vertical jump-and-reach test (for anaerobic power), T-drill test and 20-meter shuttle run test (for aerobic power) were carried out. Correlation and regression analyses were performed on the data. VO2max levels showed moderate correlations with DL's "flexor peak torque" (FPT) and NDL's "extensor peak torque" (EPT) and FPT values respectively (r=0.49, r=0.38, r=0.58). FPT of NDL was a predictor of VO2max level (R2=0.33). Anaerobic power has a relationship with EPT of NDL (r=0.43) and T-drill test with EPT and FPT values of both DL and NDL respectively (r=-0.35, r=-0.63, r=-0.53, r=-0.58). EPT of NDL was a predictor for anaerobic power (R2=0.19) and FPT of DL for agility (R2=0.40). Nonparametric linear regression results showed that EPT is a predictor in DL (median slope=-0.71, P=0.01), and FPT in NDL (median slope=-0.90, P=0.006) for FBT. FPT was a predictor of SEBT scores for both legs (0.13strength are of importance to improve orienteering performance.

  10. Large low-energy M1 strength for ^{56,57}Fe within the nuclear shell model.

    Science.gov (United States)

    Brown, B Alex; Larsen, A C

    2014-12-19

    A strong enhancement at low γ-ray energies has recently been discovered in the γ-ray strength function of ^{56,57}Fe. In this work, we have for the first time obtained theoretical γ decay spectra for states up to ≈8  MeV in excitation for ^{56,57}Fe. We find large B(M1) values for low γ-ray energies that provide an explanation for the experimental observations. The role of mixed E2 transitions for the low-energy enhancement is addressed theoretically for the first time, and it is found that they contribute a rather small fraction. Our calculations clearly show that the high-ℓ(=f) diagonal terms are most important for the strong low-energy M1 transitions. As such types of 0ℏω transitions are expected for all nuclei, our results indicate that a low-energy M1 enhancement should be present throughout the nuclear chart. This could have far-reaching consequences for our understanding of the M1 strength function at high excitation energies, with profound implications for astrophysical reaction rates.

  11. Olivetti M10

    CERN Document Server

    1983-01-01

    The Olivetti M10 is a small Italian computer, it is a first attempt to create a real laptop with its screen tilting offering a good legibility. Its success was mainly due to the good quality keyboard with its accented keys that allows a fast typing as well as has its long battery life. It can operate several hours on four standard batteries. Otherwise, in terms of software, the machine has Basic in ROM, as well as various small office programs such as spreadsheet, word processor, calendar and address book.

  12. Influence of silica fume on the strength of high strength concrete

    International Nuclear Information System (INIS)

    Akram, T.; Memon, S.A.; Khan, S.A.

    2007-01-01

    HSC (High Strength Concrete) does not become evident by a sudden change in the behavior of 'ordinary strength' concrete. There is a gradual effect that becomes more noticeable when the strength level exceeds about 40-45 MPa. There cannot be a precise level of strength which defines this change in effect. The effects are on strength and workability, requiring us to take into account in our mix proportioning, the ramifications of fineness of cement on workability and of type of aggregate and aggregate/cement ratio on strength. In fact, the selection of materials becomes more critical as the concrete strength increases and that if very high strength is required (100 MPa and higher), relatively few materials may be suitable. An experimental investigation is carried out to evaluate the feasibility of producing HSC using locally available materials and to study the influence of silica fume on the strength of HSC. The main variables in this research is amount of silica fume. The parameters that are kept constant are the amount of cement equal to 580 kg/m3, dosage of HRWRA (High Range Water Reducing Admictures) equal to 4 % by weight of cementitious materials and the ratio of fine aggregate to coarse aggregate (1:2.3). Test results revealed that it is feasible to produce HSC using locally available materials. The optimum percentage of silica fume was found to be 15 % by weight of cement. (author)

  13. A comparative effect of various surface chemical treatments on the resin composite-composite repair bond strength

    Directory of Open Access Journals (Sweden)

    Shaloo Gupta

    2015-01-01

    Full Text Available Aim: The aim of this in vitro study was an attempt to investigate the effect of different surface treatments on the bond strength between pre-existing composite and repair composite resin. Materials and Methods: Forty acrylic blocks were prepared in a cuboidal mould. In each block, a well of 5 mm diameter and 5 mm depth was prepared to retain the composite resin (Filtek™ Z350, 3M/ESPE. Aging of the composite discs was achieved by storing them in water at 37°C for 1 week, and after that were divided into 5 groups (n = 8 according to surface treatment: Group I- 37% phosphoric acid, Group II-10% hydrofluoric acid, Group III-30% citric acid, Group IV-7% maleic acid and Group V- Adhesive (no etchant. The etched surfaces were rinsed and dried followed by application of bonding agent (Adper™ Single Bond 2. 3M/ESPE. The repair composite was placed on aged composite, light-cured for 40 seconds and stored in water at 37°C for 1 week. Shear bond strength between the aged and the new composite resin was determined with a universal testing machine (crosshead speed of 0.5 mm/min. Statistical Analysis: The compressive shear strengths were compared for differences using ANOVA test followed by Tamhane′s T2 post hoc analysis. Results: The surface treatment with 10% hydrofluoric acid showed the maximum bond strength followed by 30% citric acid, 7% maleic acid and 37% phosphoric acid in decreasing order. Conclusion: The use of 10% hydrofluoric acid can be a good alternative for surface treatment in repair of composite resin restoration as compared to commonly used 37% orthophosphoric acid.

  14. Evaluation of the adhesion strength of diamond films brazed on K-10 type hard metal

    Directory of Open Access Journals (Sweden)

    Santos Sérgio Ivan dos

    2004-01-01

    Full Text Available The coating of cutting tools with diamond films considerably increases the tool performance due to the combination of the unique tribological properties of diamond with the bulk properties of the substrate (toughness. The tool performance, however, is strongly related to the adhesion strength between the film and the substrate. In this work our main goal was to propose and to test a procedure, based on a tensile strength test, to evaluate the adhesion strength of a diamond wafer brazed on a hard metal substrate, taking into account the effect of the brazing temperature and time. The temperature range studied was from 800 to 980 °C and the brazing time ranged from 3 to 40 min. The obtained results could be used to optimize the costs and time required to the production of high performance cutting tools with brazed diamond wafers.

  15. Comparison of different grinding procedures on the flexural strength of zirconia.

    Science.gov (United States)

    Işeri, Ufuk; Ozkurt, Zeynep; Yalnız, Ayşe; Kazazoğlu, Ender

    2012-05-01

    The surface of zirconia ceramic is damaged during grinding, which may affect the mechanical properties of the material. The purpose of this study was to compare the biaxial flexural strength of zirconia after different grinding procedures and to measure the temperature rise from grinding. Forty disk-shaped zirconia specimens (15 × 1.2 mm) with a smaller disk in the center of each disk (1 × 3 mm) were divided into 4 groups (n=10). The specimens were ground with a high-speed handpiece and micromotor with 2 different grinding protocols, continual grinding and periodic grinding (10 seconds grinding with 10 seconds duration), until the smaller disk was removed. Control specimens without the center disk (n=10) were analyzed without grinding. The biaxial flexural strengths of the disks were determined in a universal testing machine at a crosshead speed of 0.5 mm/min. The fracture strength (MPa) was recorded, and the results were analyzed using a 1-way ANOVA, Tukey HSD test, Student's t test, and Pearson correlation test (α=05). All grinding procedures significantly decreased flexural strength (Pmicromotor groups (718 MPa). The temperature values obtained from micromotor grinding (127°C) were significantly higher than those from high-speed handpiece grinding (63°C) (P<.01). Grinding zirconia decreased flexural strength. Zirconia material ground with a high-speed handpiece run continually caused the least reduction in flexural strength. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  16. On the 10 μm Silicate Feature in Active Galactic Nuclei

    Science.gov (United States)

    Nikutta, Robert; Elitzur, Moshe; Lacy, Mark

    2009-12-01

    The 10 μm silicate feature observed with Spitzer in active galactic nuclei (AGNs) reveals some puzzling behavior. It (1) has been detected in emission in type 2 sources, (2) shows broad, flat-topped emission peaks shifted toward long wavelengths in several type 1 sources, and (3) is not seen in deep absorption in any source observed so far. We solve all three puzzles with our clumpy dust radiative transfer formalism. Addressing (1), we present the spectral energy distribution (SED) of SST1721+6012, the first type 2 quasar observed to show a clear 10 μm silicate feature in emission. Such emission arises in models of the AGN torus easily when its clumpy nature is taken into account. We constructed a large database of clumpy torus models and performed extensive fitting of the observed SED. We find that the cloud radial distribution varies as r -1.5 and the torus contains 2-4 clouds along radial equatorial rays, each with optical depth at visual ~60-80. The source bolometric luminosity is ~3 × 1012 Lsun. Our modeling suggests that lsim35% of objects with tori sharing these characteristics and geometry would have their central engines obscured. This relatively low obscuration probability can explain the clear appearance of the 10 μm emission feature in SST1721+6012 together with its rarity among other QSO2. Investigating (2), we also fitted the SED of PG1211+143, one of the first type 1 QSOs with a 10 μm silicate feature detected in emission. Together with other similar sources, this QSO appears to display an unusually broadened feature whose peak is shifted toward longer wavelengths. Although this led to suggestions of non-standard dust chemistry in these sources, our analysis fits such SEDs with standard galactic dust; the apparent peak shifts arise from simple radiative transfer effects. Regarding (3), we find additionally that the distribution of silicate feature strengths among clumpy torus models closely resembles the observed distribution, and the feature

  17. Shear bond strength of different adhesives tested in accordance with DIN 13990-1/-2 and using various methods of enamel conditioning.

    Science.gov (United States)

    Richter, C; Jost-Brinkmann, P-G

    2015-03-01

    The purpose of this work was to analyze the shear bond strength (SBS) of different adhesives for orthodontic brackets in accordance with DIN 13990-1/-2, also taking into consideration potential effects arising from different scenarios of enamel conditioning and specimen storage. A total of 390 experiments were performed, with groups of 10 specimens subjected to identical treatments. Three adhesives were tested: Transbond™ XT (3M Unitek, Monrovia, USA), Beauty Ortho Bond (Shofu, Kyoto, Japan), and Fuji Ortho LC (GC Europe, Leuven, Belgium). SBS was evaluated separately at the bracket-adhesive and adhesive-enamel interfaces, as well as the total (enamel-adhesive-bracket) interface. The brackets were metal brackets for upper right central incisors (Discovery® from Dentaurum, Ispringen, Germany). A universal testing machine (Zwick Z010, Ulm, Germany) was used for testing the SBS after 15 min, or after storage in distilled water at 37 °C for 24 h, or after 24 h followed by 500 thermocycles alternating between 5 and 55 °C. Transbond™ XT produced the highest levels of SBS. The least favorable performance was observed with Fuji Ortho LC after enamel conditioning with 10 % polyacrylic acid. Thermocycling did not have a significant influence. Transbond™ XT and Beauty Ortho Bond (but not Fuji Ortho LC) yielded levels of SBS adequate for clinical application (≥ 7 MPa).

  18. Increased skeletal muscle 11βHSD1 mRNA is associated with lower muscle strength in ageing.

    Directory of Open Access Journals (Sweden)

    Alixe H M Kilgour

    Full Text Available Sarcopenia, the loss of muscle mass and function with age, is associated with increased morbidity and mortality. Current understanding of the underlying mechanisms is limited. Glucocorticoids (GC in excess cause muscle weakness and atrophy. We hypothesized that GC may contribute to sarcopenia through elevated circulating levels or increased glucocorticoid receptor (GR signaling by increased expression of either GR or the GC-amplifying enzyme 11 beta-hydroxysteroid dehydrogenase type 1 (11βHSD1 in muscle.There were 82 participants; group 1 comprised 33 older men (mean age 70.2 years, SD 4.4 and 19 younger men (22.2 years, 1.7 and group 2 comprised 16 older men (79.1 years, 3.4 and 14 older women (80.1 years, 3.7. We measured muscle strength, mid-thigh cross-sectional area, fasting morning plasma cortisol, quadriceps muscle GR and 11βHSD1 mRNA, and urinary glucocorticoid metabolites. Data were analysed using multiple linear regression adjusting for age, gender and body size.Muscle strength and size were not associated with plasma cortisol, total urinary glucocorticoids or the ratio of urinary 5β-tetrahydrocortisol +5α-tetrahydrocortisol to tetrahydrocortisone (an index of systemic 11βHSD activity. Muscle strength was associated with 11βHSD1 mRNA levels (β -0.35, p = 0.04, but GR mRNA levels were not significantly associated with muscle strength or size.Although circulating levels of GC are not associated with muscle strength or size in either gender, increased cortisol generation within muscle by 11βHSD1 may contribute to loss of muscle strength with age, a key component of sarcopenia. Inhibition of 11βHSD1 may have therapeutic potential in sarcopenia.

  19. The relationship between compressive strength and flexural strength of pavement geopolymer grouting material

    Science.gov (United States)

    Zhang, L.; Han, X. X.; Ge, J.; Wang, C. H.

    2018-01-01

    To determine the relationship between compressive strength and flexural strength of pavement geopolymer grouting material, 20 groups of geopolymer grouting materials were prepared, the compressive strength and flexural strength were determined by mechanical properties test. On the basis of excluding the abnormal values through boxplot, the results show that, the compressive strength test results were normal, but there were two mild outliers in 7days flexural strength test. The compressive strength and flexural strength were linearly fitted by SPSS, six regression models were obtained by linear fitting of compressive strength and flexural strength. The linear relationship between compressive strength and flexural strength can be better expressed by the cubic curve model, and the correlation coefficient was 0.842.

  20. ISRU Soil Mechanics Vacuum Facility: Soil Bin Preparation and Simulant Strength Characterization

    Science.gov (United States)

    Kleinhenz, Julie; Wilkinson, Allen

    2012-01-01

    Testing in relevant environments is key to exploration mission hardware development. This is true on both the component level (in early development) and system level (in late development stages). During ISRU missions the hardware will interface with the soil (digging, roving, etc) in a vacuum environment. A relevant test environment will therefore involve a vacuum chamber with a controlled, conditioned simulant bed. However, in earth-based granular media, such as lunar soil simulant, gases trapped within the material pore structures and water adsorbed to all particle surfaces will release when exposed to vacuum. Early vacuum testing has shown that this gas release can occur violently, which loosens and weakens the simulant, altering the consolidation state. The Vacuum Facility #13, a mid-size chamber (3.66m tall, 1.5m inner diameter) at the NASA Glenn Research Center has been modified to create a soil mechanics test facility. A 0.64m deep by 0.914m square metric ton bed of lunar simulant was placed under vacuum using a variety of pumping techniques. Both GRC-3 and LHT-3M simulant types have been used. An electric cone penetrometer was used to measure simulant strength properties at vacuum including: cohesion, friction angle, bulk density and shear modulus. Simulant disruptions, caused by off gassing, affected the strength properties, but could be mitigated by reducing pump rate. No disruptions were observed at pressures below 2.5Torr, regardless of the pump rate. However, slow off gassing of the soil lead to long test times, a full week, to reach 10-5Torr. This work highlights the need for robotic machine-simulant hardware and operations in vacuum to expeditiously perform (sub-)systems tests.

  1. Fracture toughness and strength change of neutron-irradiated ceramic materials

    International Nuclear Information System (INIS)

    Dienst, W.; Zimmermann, H.

    1994-01-01

    In order to analyse the results of bending strength measurements on neutron-irradiated samples of Al 2 O 3 , AlN and SiC, fracture toughness measurements were additionally conducted. The neutron fluences concerned were mostly in the range of 0.6 to 3.2x10 26 n/m 2 at irradiation temperatures of 400 to 550 C. A fracture toughness decrease was generally observed for polycrystalline materials which, however, was considerably smaller than the reduction of the fracture strength. Exceptional increase of the fracture toughness seems typical for the effect of rather coarse irradiation defects. The irradiation-induced change of the fracture toughness of single crystal Al 2 O 3 appeared dependent on the crystallographic orientation; both reduced and increased fracture toughness after irradiation was observed. Recent results of neutron irradiation to about 2x10 25 n/m 2 at 100 C showed, that the strength decrease of various Al 2 O 3 grades sets in at (3-5)x10 24 n/m 2 and seems to be little dependent on the irradiation temperature. ((orig.))

  2. Influence of artificial aging on the shear bond strength of zirconia-composite interfaces after pretreatment with new 10-MDP adhesive systems

    Directory of Open Access Journals (Sweden)

    p.c pott

    2016-03-01

    Full Text Available Introduction: This in-vitro study investigates the bond strength of different zirconia composites  with three different modern adhesive systems after artificial aging using thermocycling and water storage. Methods: A total of 90 specimens of zirconia (InCoris, Sirona, Germany, Bernsheim were ground using a 165 µm grit rotating diamond disc. Thirty specimens were additionally treated with either Futurabond U “FBU” (VOCO GmbH, or Futurabond M+ “FBM” (VOCO GmbH or Futurabond M+ in combination with the DCA activator “FBMD” (VOCO GmbH. One of the three different types of composites – BifixSE “BS”, BifixQM “BQ” or GrandioSO “G” (VOCO GmbH – was bonded to the ten specimens of each group. All of the specimens underwent artificial aging using thermocycling between 5°C and 55°C for 5000 cycles followed by water storage for 100 days. Shear bond strength (SBS was determined in a universal testing machine. The type of failure was evaluated using fluorescence microscopy. The data were compared to existing data without artificial aging. Statistical analysis was performed with ANOVA and the Tukey test. Results: FBM and FBMD had higher SBS than FBU in combination with all tested composites, except BifixSE. In nearly all groups, artificial aging had no effect, with the exception of the combination of FBMD with BifixSE, in which there was a significant decrease in SBS after the aging process (p

  3. Experimental investigations and improvements for the 10 K G-M refrigerator

    Science.gov (United States)

    Hao, Xihuan; Ju, Yonglin

    2012-06-01

    With the wide application of high performance cryo-pumps, high and low temperature superconducting devices, MRI, infrared detectors and cryogenic electronics, the development of high efficient and reliable 10 K G-M refrigerator is of critical importance and awaited by cryogenic industries. In the past two years, systematic studies have been carried out, and detailed experimental tests indicated that the cooling performance of the 10 K G-M refrigerator was improved by adding two additional rectification meshes inside the low temperature regenerator and by optimizing the system charge pressure. Furthermore, a new labyrinth sealing displacer was proposed and fabricated to substitute the traditional piston-ring sealing displacer for improved operating stability and reliability of the 10 K GM refrigerator. The detailed experimental results and improvements were summarized and their optimal cases were given in this paper.

  4. Effect of collagen fibrils removal on shear bond strength of total etch and self etch adhesive systems

    Directory of Open Access Journals (Sweden)

    Pishevar L.

    2009-12-01

    Full Text Available "nBackground and Aim: Sodium hypochlorite can remove the organic phase of the demineralized dentin and it produces direct resin bonding with hydroxyapatite crystals. Therefore, the hydrolytic degradation of collagen fibrils which might affect the bonding durability is removed. The aim of this study was to evaluate the effect of collagen fibrils removal by 10% NaOCl on dentin shear bond strength of two total etch and self etch adhesive systems."nMaterials and Methods: Sixty extracted human premolar teeth were used in this study. Buccal surface of teeth were grounded until dentin was exposed. Then teeth were divided into four groups. According to dentin surface treatment, experimental groups were as follows: Group I: Single Bond (3M according to manufacture instruction, Group II: 10% NaOCl+Single bond (3M, Group III: Clearfil SE Bond (Kuraray according to manufacture instruction, and Group IV: Clearfil SE Bond primer. After that, the specimens were immersed in 50% acetone solution for removing extra monomer. Then the specimens were rinsed and dried. 10% NaOCl was applied and finally adhesive was used. Then composite was bonded to the treated surfaces using a 4 2 mm cylindrical plastic mold. Specimens were thermocycled for 500 cycles (5-55ºC. A shear load was employed by a universal testing machine with a cross head speed of 1mm/min. The data were analyzed for statistical significance with One-way ANOVA, Two-way ANOVA and Tukey HSD post-hoc tests."nResults: The mean shear bond strengths of groups were as follows: Single Bond=16.8±4.2, Clearfil SE Bond=23.7±4.07, Single Bond+NaOCl=10.5±4.34, Clearfil SE Bond+NaOCl=23.3±3.65 MPa. Statistical analysis revealed that using 10% NaOCl significantly decreased the shear bond strength in Single Bond group (P=0.00, but caused no significant difference in the shear bond strength in Clearfil SE Bond group (P=0.99."nConclusion: Based on the results of this study, NaOCl treatment did not improve the bond

  5. Strength Prediction and Failure Modes of Concrete Specimens Subjected to the Split Test

    DEFF Research Database (Denmark)

    Hoang, Linh Cao; Andersen, M.E.; Hansen, N.T.

    2014-01-01

    This paper deals with modelling and test of concrete specimens subjected to the Brazilian split test. Based on the fictitious crack concept, a simple model for the crack propagation process in the splitting plane is developed. From the model, it is possible to determine the distribution of residual...... tensile strength as crack propagation take place. The residual tensile strength is thereafter used in a rigid plastic analysis of the splitting failure. Based on this combined approach, the ultimate load may either be governed by crack propagation or by a plastic failure, which then terminates the crack...

  6. A Comparison of Isometric Midthigh-Pull Strength, Vertical Jump, Sprint Speed, and Change-of-Direction Speed in Academy Netball Players.

    Science.gov (United States)

    Thomas, Christopher; Comfort, Paul; Jones, Paul A; Dos'Santos, Thomas

    2017-08-01

    To investigate the relationships between maximal isometric strength, vertical jump (VJ), sprint speed, and change-of-direction speed (CoDS) in academy netball players and determine whether players who have high performance in isometric strength testing would demonstrate superior performance in VJ, sprint speed, and CoDS measures. Twenty-six young female netball players (age 16.1 ± 1.2 y, height 173.9 ± 5.7 cm, body mass 66.0 ± 7.2 kg) from a regional netball academy performed isometric midthigh pull (IMTP), squat jumps (SJs), countermovement jumps (CMJs), 10-m sprints, and CoDS (505). IMTP measures displayed moderate to strong correlations with sprint and CoDS performance (r = -.41 to -.66). The VJs, which included SJs and CMJs, demonstrated strong correlations with 10-m sprint times (r = -.60 to -.65; P strength to enhance VJ, sprint, and CoDS performance in youth netball players, with stronger athletes demonstrating superior VJ, sprint, and CoDS performances.

  7. Avaliação da função manual e da força de preensão palmar máxima em indivíduos com diabetes mellitus Hand function and power grip strength assessment in individuals with diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Kauê Carvalho de Almeida Lima

    2012-12-01

    involving object manipulation. The aim of the study was to compare the performance of diabetic individual without diagnosis of neuropathy with non-diabetic healthy individuals in manipulation task and their maximum power grip strength. Thirteen diabetic individuals without peripheral neuropathy diagnosis (48.6±11.51 years-old; 79.9±10.88 kg; 1.68±0.09 m and 13 healthy age- and gender-matched controls (48.5±10.09 years-old; 76.44±11.79 kg; 1.69±0.1 m participated in the study. Hand cutaneous sensitivity was assessed by the Semmes-Weinstein monofilaments examination (SWME followed by the application of three tests commonly used to assess hand function: Jebsen-Taylor hand function test (JTHFT, nine hole peg test (9HPT and maximum power grip strength test (GSmax. The results of SWME revealed that eight diabetic individuals presented normal cutaneous sensitivity and five showed mild sensory losses, but that was not enough to characterize them as neuropathic diabetics. Regarding the hand function tests, the results revealed no difference between diabetic individuals and healthy controls in any of the tests performed (diabetic individuals and controls - JHHFT: 26.15±3.06 and 25.78±1.29 s; 9HPT: 15.33±1.35 and 15.48±2.39 s; GSmax: 41.15±10.59 and 43.69±12.59 kgf. Therefore, we conclude that diabetic individuals without neuropathy show no hand function impairment, as well as no reduction in the maximum power grip strength.

  8. Effect of testing methods on the bond strength of resin to zirconia-alumina ceramic : microtensile versus shear test

    NARCIS (Netherlands)

    Valandro, Luiz F.; Ozcan, Mutlu; Amaral, Regina; Vanderlei, Aleska; Bottino, Marco A.

    2008-01-01

    This study tested the bond strength of a resin cement to a glass-infiltrated zirconia-alumina ceramic after three conditioning methods and using two test methods (shear-SBS versus microtensile-MTBS). Ceramic blocks for MTBS and ceramic disks for SBS were fabricated. Three surface conditioning (SC)

  9. Reliability and Sensitivity of the Power Push-up Test for Upper-Body Strength and Power in 6-15-Year-Old Male Athletes.

    Science.gov (United States)

    Gillen, Zachary M; Miramonti, Amelia A; McKay, Brianna D; Jenkins, Nathaniel D M; Leutzinger, Todd J; Cramer, Joel T

    2018-01-01

    Gillen, ZM, Miramonti, AA, McKay, BD, Jenkins, NDM, Leutzinger, TJ, and Cramer, JT. Reliability and sensitivity of the power push-up test for upper-body strength and power in 6-15-year-old male athletes. J Strength Cond Res 32(1): 83-96, 2018-The power push-up (PPU) test is an explosive upper-body test performed on a force plate and is currently being used in high school football combines throughout the United States. The purpose of this study was to quantify the reliability of the PPU test based on age and starting position (knees vs. toes) in young athletes. Sixty-eight boys (mean ± SD; age = 10.8 ± 2.0 years) were tested twice over 5 days. Boys were separated by age as 6-9 years (n = 16), 10-11 years (n = 26), and 12-15 years (n = 26). The PPU test was performed on a force plate while rotating from the knees vs. the toes. Measurements were peak force (PF, N), peak rate of force development (pRFD, N·s), average power (AP, W), and peak power (PP, W). Intraclass correlation coefficients (ICC2,1), SEMs, coefficients of variation (CVs), and minimum detectable changes (MDCs) were calculated to quantify reliability and sensitivity. Peak force from the knees in 10-15-year-olds, PF from the toes in 12-15-year-olds, and pRFD from the knees and toes in 12-15-year-olds were comparably reliable (ICC ≥ 0.84). Neither power measurements (AP or PP) for any age group, nor any measurements (PF, pRFD, AP, or PP) for the 6-9-year-olds were comparably reliable (ICC ≤ 0.74). When considering the reliable variables, PF was greater in the 12-15-year-olds than in 10-11-year-olds (p ≤ 0.05). In addition, in 12-15-year-olds, PF and pRFD were greater from the knees than from the toes (p ≤ 0.05). For reasons largely attributable to growth and development, the PPU test may be a reliable (ICC ≥ 0.80) and sensitive (CV ≤ 19%) measure of upper-body strength (PF), whereas pRFD was also reliable (ICC ≥ 0.80), but less sensitive (CV = 30-38%) in 10-15-year-old male athletes.

  10. Small-Scale Water Ingression and Crust Strength Tests (SSWICS) SSWICS-6 test data report: thermal hydraulic results, Rev. 0

    International Nuclear Information System (INIS)

    Lomperski, S.; Farmer, M.T.; Kilsdonk, D.; Aeschlimann, B.

    2011-01-01

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure? (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are being conducted to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium (∼ φ 30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. The issue of crust strength is being addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus measures the fracture strength of the crust while it is either at room temperature or above, the latter state being achieved with a heating element placed below the crust. The two apparatuses used to measure the melt quench rate and crust strength are jointly referred to as SSWICS (Small-Scale Water Ingression and Crust Strength). This report describes results of the sixth water ingression test, designated SSWICS-6. This test investigated

  11. Hip abduction-adduction strength and one-leg hop tests: test-retest reliability and relationship to function in elite ice hockey players.

    Science.gov (United States)

    Kea, J; Kramer, J; Forwell, L; Birmingham, T

    2001-08-01

    Single group, test-retest. To determine: (1) hip abduction and adduction torques during concentric and eccentric muscle actions, (2) medial and lateral one-leg hop distances, (3) the test-retest reliability of these measurements, and (4) the relationship between isokinetic measures of hip muscle strength and hop distances in elite ice hockey players. The skating motion used in ice hockey requires strong contractions of the hip and knee musculature. However, baseline scores for hip strength and hop distances, their test-retest reliability, and measures of the extent to which these tests are related for this population are not available. The dominant leg of 27 men (mean age 20 +/- 3 yrs) was tested on 2 occasions. Hip abduction and adduction movements were completed at 60 degrees.s(-1) angular velocity, with the subject lying on the non-test side and the test leg moving vertically in the subject's coronal plane. One-leg hops requiring jumping from and landing on the same leg without losing balance were completed in the medial and lateral directions. Hip adduction torques were significantly greater than abduction torques during both concentric and eccentric muscle actions, while no significant difference was observed between medial and lateral hop distances. Although hop test scores produced excellent ICCs (> 0.75) when determined using scores on 1 occasion, torques needed to be averaged over 2 test occasions to reach this level. Correlations between the strength and hop tests ranged from slight to low (r = -0.26 to 0.27) and were characterized by wide 95% confidence intervals (-0.54 to 0.61). Isokinetic tests of hip abduction and adduction did not provide a strong indication of performance during sideways hop tests. Although isokinetic tests can provide a measure of muscular strength under specific test conditions, they should not be relied upon as a primary indicator of functional abilities or readiness to return to activity.

  12. Reliability of a device for the knee and ankle isometric and isokinetic strength testing in older adults.

    Science.gov (United States)

    Bergamin, Marco; Gobbo, Stefano; Bullo, Valentina; Vendramin, Barbara; Duregon, Federica; Frizziero, Antonio; Di Blasio, Andrea; Cugusi, Lucia; Zaccaria, Marco; Ermolao, Andrea

    2017-01-01

    Lower extremity muscle mass, strength, power, and physical performance are critical determinants of independent functioning in later life. Isokinetic dynamometers are becoming very common in assessing different features of muscle strength, in both research and clinical practice; however, reliability studies are still needed to support the extended use of those devices. The purpose of this study is to assess the test-retest reliability of knee and ankle isokinetic and isometric strength testing protocols in a sample of older healthy subjects, using a new and untested isokinetic multi-joint evaluation system. Sixteen male and fourteen female older adults (mean age 65.2 ± 4.6 years) were assessed in two testing sessions. Each participant performed a randomized testing procedure that includes different isometric and isokinetic tests for knee and ankle joints. All participants concluded the trial safety and no subject reported any discomfort throughout the overall assessment. Coefficients of correlation between measures were calculated showing moderate to strong effects among all test-retest assessments and paired-sample t test showed only one significant difference (pisometric strength provided reliable test-retest measures in healthy older adults. Ib.

  13. On the impact bending test technique for high-strength pipe steels

    Science.gov (United States)

    Arsenkin, A. M.; Odesskii, P. D.; Shabalov, I. P.; Likhachev, M. V.

    2015-10-01

    It is shown that the impact toughness (KCV-40 = 250 J/cm2) accepted for pipe steels of strength class K65 (σy ≥ 550 MPa) intended for large-diameter gas line pipes is ineffective to classify steels in fracture strength. The results obtained upon testing of specimens with a fatigue crack and additional sharp lateral grooves seem to be more effective. In energy consumption, a macrorelief with splits is found to be intermediate between ductile fracture and crystalline brittle fracture. A split formation mechanism is considered and a scheme is proposed for split formation.

  14. Grinding damage assessment on four high-strength ceramics.

    Science.gov (United States)

    Canneto, Jean-Jacques; Cattani-Lorente, Maria; Durual, Stéphane; Wiskott, Anselm H W; Scherrer, Susanne S

    2016-02-01

    The purpose of this study was to assess surface and subsurface damage on 4 CAD-CAM high-strength ceramics after grinding with diamond disks of 75 μm, 54 μm and 18 μm and to estimate strength losses based on damage crack sizes. The materials tested were: 3Y-TZP (Lava), dense Al2O3 (In-Ceram AL), alumina glass-infiltrated (In-Ceram ALUMINA) and alumina-zirconia glass-infiltrated (In-Ceram ZIRCONIA). Rectangular specimens with 2 mirror polished orthogonal sides were bonded pairwise together prior to degrading the top polished surface with diamond disks of either 75 μm, 54 μm or 18 μm. The induced chip damage was evaluated on the bonded interface using SEM for chip depth measurements. Fracture mechanics were used to estimate fracture stresses based on average and maximum chip depths considering these as critical flaws subjected to tension and to calculate possible losses in strength compared to manufacturer's data. 3Y-TZP was hardly affected by grinding chip damage viewed on the bonded interface. Average chip depths were of 12.7±5.2 μm when grinding with 75 μm diamond inducing an estimated loss of 12% in strength compared to manufacturer's reported flexural strength values of 1100 MPa. Dense alumina showed elongated chip cracks and was suffering damage of an average chip depth of 48.2±16.3 μm after 75 μm grinding, representing an estimated loss in strength of 49%. Grinding with 54 μm was creating chips of 32.2±9.1 μm in average, representing a loss in strength of 23%. Alumina glass-infiltrated ceramic was exposed to chipping after 75 μm (mean chip size=62.4±19.3 μm) and 54 μm grinding (mean chip size=42.8±16.6 μm), with respectively 38% and 25% estimated loss in strength. Alumina-zirconia glass-infiltrated ceramic was mainly affected by 75 μm grinding damage with a chip average size of 56.8±15.1 μm, representing an estimated loss in strength of 34%. All four ceramics were not exposed to critical chipping at 18 μm diamond grinding. Reshaping a

  15. Progressive strength training (10 RM) commenced immediately after fast-track total knee arthroplasty: is it feasible?

    DEFF Research Database (Denmark)

    Jakobsen, Thomas Linding; Husted, Henrik; Kehlet, Henrik

    2012-01-01

    . They received rehabilitation including progressive strength training of the operated leg (leg press and knee-extension), using relative loads of 10 repetition maximum with three training sessions per week for 2 weeks. Rehabilitation was commenced 1 or 2 days after TKA. At each training session, knee pain, knee...... joint effusion and training load were recorded. Isometric knee-extension strength and maximal walking speed were measured before the first and last session. Results: The training load increased progressively (p training exercises......, but knee pain at rest and knee joint effusion (p training sessions. Isometric knee-extension strength and maximal walking speed increased by 147 and 112%, respectively. Conclusion: Progressive strength training initiated immediately after TKA seems feasible...

  16. STRENGTH OF NANOMODIFIED HIGH-STRENGTH LIGHTWEIGHT CONCRETES

    Directory of Open Access Journals (Sweden)

    NOZEMTСEV Alexandr Sergeevich

    2013-02-01

    Full Text Available The paper presents the results of research aimed at development of nanomodified high-strength lightweight concrete for construction. The developed concretes are of low average density and high ultimate compressive strength. It is shown that to produce this type of concrete one need to use hollow glass and aluminosilicate microspheres. To increase the durability of adhesion between cement stone and fine filler the authors offer to use complex nanodimensinal modifier based on iron hydroxide sol and silica sol as a surface nanomodifier for hollow microspheres. It is hypothesized that the proposed modifier has complex effect on the activity of the cement hydration and, at the same time increases bond strength between filler and cement-mineral matrix. The compositions for energy-efficient nanomodified high-strength lightweight concrete which density is 1300…1500 kg/m³ and compressive strength is 40…65 MPa have been developed. The approaches to the design of high-strength lightweight concrete with density of less than 2000 kg/m³ are formulated. It is noted that the proposed concretes possess dense homogeneous structure and moderate mobility. Thus, they allow processing by vibration during production. The economic and practical implications for realization of high-strength lightweight concrete in industrial production have been justified.

  17. Accelerated Comparative Fatigue Strength Testing of Belt Adhesive Joints

    Science.gov (United States)

    Bajda, Miroslaw; Blazej, Ryszard; Jurdziak, Leszek

    2017-12-01

    Belt joints are the weakest link in the serial structure that creates an endless loop of spliced belt segments. This affects not only the lower strength of adhesive joints of textile belts in comparison to vulcanized splices, but also the replacement of traditional glues to more ecological but with other strength parameters. This is reflected in the lowered durability of adhesive joints, which in underground coal mines is nearly twice shorter than the operating time of belts. Vulcanized splices require high precision in performance, they need long time to achieve cross-linking of the friction mixture and, above all, they require specialized equipment (vulcanization press) which is not readily available and often takes much time to be delivered down, which means reduced mining output or even downtime. All this reduces the reliability and durability of adhesive joints. In addition, due to the consolidation on the Polish coal market, mines are joined into large economic units serviced by a smaller number of processing plants. The consequence is to extend the transport routes downstream and increase reliability requirements. The greater number of conveyors in the chain reduces reliability of supply and increases production losses. With high fixed costs of underground mines, the reduction in mining output is reflected in the increase in unit costs, and this at low coal prices on the market can mean substantial losses for mines. The paper describes the comparative study of fatigue strength of shortened samples of adhesive joints conducted to compare many different variants of joints (various adhesives and materials). Shortened samples were exposed to accelerated fatigue in the usually long-lasting dynamic studies, allowing more variants to be tested at the same time. High correlation between the results obtained for shortened (100 mm) and traditional full-length (3×250 mm) samples renders accelerated tests possible.

  18. Assessing Reactive Strength Measures in Jumping and Hopping Using the Optojump™ System

    Directory of Open Access Journals (Sweden)

    Healy Robin

    2016-12-01

    Full Text Available The aim of this study was to assess the concurrent validity of the Optojump™ system (Microgate, Bolzano, Italy versus a force platform in the estimation of temporal and reactive strength measures. In two separate investigations, twenty physically active males performed double-leg and single-leg drop jumps from a box height of 0.3 m and a 10 s vertical bilateral hopping test. Contact time, flight time and total time (the sum of contact and flight time were concurrently assessed during single and double-leg drop jumps and during hopping. Jump height, the reactive strength index and the reactive strength ratio were also calculated from contact time and flight time. Despite intraclass correlation coefficients (ICCs for all variables being close to 1 (ICC > 0.975, a significant overestimation was found in contact time (0.005 ± 0.002 s and underestimations in flight time (0.005 ± 0.003 s, the reactive strength index (0.04 ± 0.02 m·s-1 and the reactive strength ratio (0.07 ± 0.04. Overestimations in contact time and underestimations in flight time were attributed to the physical design of the Optojump™ system as the transmitter and receiver units were positioned 0.003 m above the floor level. The Optojump™ demonstrated excellent overall temporal validity with no differences found between systems for total time. Coaches are advised to be consistent with the instrumentation used to assess athletes, however, in the case of comparison between reactive strength values collected with the Optojump™ and values collected with a force platform, regression equations are provided.

  19. 46 CFR 54.10-10 - Standard hydrostatic test (modifies UG-99).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Standard hydrostatic test (modifies UG-99). 54.10-10... PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-10 Standard hydrostatic test (modifies UG-99). (a) All pressure vessels shall satisfactorily pass the hydrostatic test prescribed by this section...

  20. Is strength-training frequency a key factor to develop performance adaptations in young elite soccer players?

    Science.gov (United States)

    Otero-Esquina, Carlos; de Hoyo Lora, Moisés; Gonzalo-Skok, Óliver; Domínguez-Cobo, Sergio; Sánchez, Hugo

    2017-11-01

    The aim of this study was to analyse the effects of a combined strength-training programme (full-back squat, YoYo TM leg curl, plyometrics and sled towing exercises) on performance in elite young soccer players and to examine the effects when this training programme was performed one or two days per week. Thirty-six male soccer players (U-17 to U-19) were recruited and assigned to experimental groups (EXP1: 1 s w -1 ; EXP2: 2 s w -1 ) or a control group (CON). Performance was assessed through a countermovement jump (CMJ) test (relative peak power [CMJ PP ] and CMJ height [CMJ H ]), a 20-m linear sprint test with split-times at 10-m, and a change of direction test (V-cut test) 1 week before starting the training programme and also 1 week after performing such training programme. Within-group analysis showed substantial improvements in CMJ variables (ES: 0.39-0.81) and COD (ES: 0.70 and 0.76) in EXP1 and EXP2, while EXP2 also showed substantial enhancements in all linear sprinting tests (ES: 0.43-0.52). Between-group analysis showed substantially greater improvements in CMJ variables (ES: 0.39-0.68) in experimental groups in comparison to CON. Furthermore, EXP2 achieved a substantial better performance in 20-m (ES: 0.48-0.64) than EXP1 and CON. Finally, EXP2 also showed greater enhancements in 10-m (ES: 0.50) and V-cut test (ES: 0.52) than EXP1. In conclusion, the combined strength-training programme improved jumping ability, independently of training frequency, though the achievement of two sessions per week also enhanced sprinting abilities (linear and COD) in young soccer players.

  1. The minimum sit-to-stand height test: reliability, responsiveness and relationship to leg muscle strength.

    Science.gov (United States)

    Schurr, Karl; Sherrington, Catherine; Wallbank, Geraldine; Pamphlett, Patricia; Olivetti, Lynette

    2012-07-01

    To determine the reliability of the minimum sit-to-stand height test, its responsiveness and its relationship to leg muscle strength among rehabilitation unit inpatients and outpatients. Reliability study using two measurers and two test occasions. Secondary analysis of data from two clinical trials. Inpatient and outpatient rehabilitation services in three public hospitals. Eighteen hospital patients and five others participated in the reliability study. Seventy-two rehabilitation unit inpatients and 80 outpatients participated in the clinical trials. The minimum sit-to-stand height test was assessed using a standard procedure. For the reliability study, a second tester repeated the minimum sit-to-stand height test on the same day. In the inpatient clinical trial the measures were repeated two weeks later. In the outpatient trial the measures were repeated five weeks later. Knee extensor muscle strength was assessed in the clinical trials using a hand-held dynamometer. The reliability for the minimum sit-to-stand height test was excellent (intraclass correlation coefficient (ICC) 0.91, 95% confidence interval (CI) 0.81-0.96). The standard error of measurement was 34 mm. Responsiveness was moderate in the inpatient trial (effect size: 0.53) but small in the outpatient trial (effect size: 0.16). A small proportion (8-17%) of variability in minimum sit-to-stand height test was explained by knee extensor muscle strength. The minimum sit-to-stand height test has excellent reliability and moderate responsiveness in an inpatient rehabilitation setting. Responsiveness in an outpatient rehabilitation setting requires further investigation. Performance is influenced by factors other than knee extensor muscle strength.

  2. Detection test of wireless network signal strength and GPS positioning signal in underground pipeline

    Science.gov (United States)

    Li, Li; Zhang, Yunwei; Chen, Ling

    2018-03-01

    In order to solve the problem of selecting positioning technology for inspection robot in underground pipeline environment, the wireless network signal strength and GPS positioning signal testing are carried out in the actual underground pipeline environment. Firstly, the strength variation of the 3G wireless network signal and Wi-Fi wireless signal provided by China Telecom and China Unicom ground base stations are tested, and the attenuation law of these wireless signals along the pipeline is analyzed quantitatively and described. Then, the receiving data of the GPS satellite signal in the pipeline are tested, and the attenuation of GPS satellite signal under underground pipeline is analyzed. The testing results may be reference for other related research which need to consider positioning in pipeline.

  3. Comparison of two bond strength testing methodologies for bilayered all-ceramics

    NARCIS (Netherlands)

    Dundar, Mine; Ozcan, Mutlu; Gokce, Bulent; Comlekoglu, Erhan; Leite, Fabiola; Valandro, Luiz Felipe

    Objectives. This study compared the shear bond strength (SBS) and microtensile (MTBS) testing methodologies for core and veneering ceramics in four types of all-ceramic systems. Methods. Four different ceramic veneer/core combinations, three of which were feldspathic and the other a fluor-apatite to

  4. The fracture strength by a torsion test at the implant-abutment interface.

    Science.gov (United States)

    Watanabe, Fumihiko; Hiroyasu, Kazuhiko; Ueda, Kazuhiko

    2015-12-01

    Fractured connections between implants and implant abutments or abutment screws are frequently encountered in a clinical setting. The purpose of this study was to investigate fracture strength using a torsion test at the interface between the implant and the abutment. Thirty screw-type implant with diameters of 3.3, 3.8, 4.3, 5.0, and 6.0 mm were submitted to a torsion test. Implants of each size were connected to abutments with abutment screws tightened to 20 N · cm. Mechanical stress was applied with a rotational speed of 3.6 °/min until fracture occurred, and maximum torque (fracture torque) and torsional yield strength were measured. The mean values were calculated and then compared using Tukey's test. The abutments were then removed, and the implant-abutment interfaces were examined using a scanning electron microscope (SEM). No significant differences in mean fracture torque were found among 3.3, 3.8, and 4.3 mm-diameter implants, but significant differences were found between these sizes and 5.0 and 6.0 mm-diameter implants (p abutment corresponding to the internal notches of the implant body had been destroyed. Smaller diameter implants demonstrated lower fracture torque and torsional yield strength than implants with larger diameters. In internal tube-in-tube connections, three abutment projections corresponding to rotation-prevention notches were destroyed in each implant.

  5. Influence of multiaxial preloading on the strength of concrete

    International Nuclear Information System (INIS)

    Linse, D.

    1975-01-01

    In a preliminary study about the influence of the loading direction discs of 20/20/5 cm were loaded at different stress-rates in one direction, then unloaded and loaded up to failure again. Two series of each about 15 specimens were tested: the first series was reloaded in the same direction as it was loaded before. If the preloading was not greater than about 90% of the original short-term uniaxial strength βsub(p), one could achieve in the second loading a higher strength than the strength βsub(p). The second series was reloaded normal to the direction of preloading. By an other series of about 50 specimens the influence of triaxial preloading on the uniaxial strength of concrete was tested. Cubes of 10cm were loaded by brush bearing platens up to a stress which was maximally three times higher than the uniaxial short-term strength βsub(p), then unloaded and tested again under uniaxial compression. The achieved ultimate strength of the cubes at the second loading was obviously dependent upon the stress-state and the stress-rate of the preloading. Multiaxial preloading which is far below the ultimate multiaxial strength can considerably defect the remaining strength of concrete. The decrease in strength was defined by the reduction of the uniaxial strength. It can be assumed that the remaining multiaxial strength is reduced at least to the same rate. Further tests are planned

  6. Comparative study of the dental substrate used in shear bond strength tests

    Directory of Open Access Journals (Sweden)

    Lopes Murilo Baena

    2003-01-01

    Full Text Available The purpose of this study was to compare shear bond strength values obtained in human enamel and dentin with the values obtained in bovine teeth using two adhesive systems with different actions. Forty human tooth half-crowns and forty bovine tooth crowns were flattened to a minimum plain area of 5 mm in diameter. The samples were divided in four groups of 20 specimens each: 1 human enamel; 2 bovine enamel; 3 human dentin; 4 bovine dentin. The samples of each group were divided in 2 subgroups of 10 samples each, according to the adhesive system used: 1 Scotchbond Multi-Purpose (SBMP; and 2 Clearfil Liner Bond 2V (CLB2V applied according to the manufacturer's recommendations. Afterwards, restorations of Z100 composite with cylindrical shape (4 mm diameter x 5 mm height were made using a metallic mold to submit the samples to shear bond testing on an Instron universal testing machine, at a crosshead speed of 0.5 mm/min. The data were submitted to ANOVA and Tukey's test (5%. In enamel, there was no statistical difference between bovine and human teeth for SBMP (7.36 MPa, human; 8.24 MPa, bovine, nor for CLB2V (10.01 MPa, human; 7.95, bovine. In dentin, SBMP showed a statistically lower mean on human dentin (7.01 MPa than on bovine dentin (11.74 MPa. For CLB2V, there was no statistical difference between human (7.43 MPa and bovine (9.27 MPa substrates.

  7. The effects of silver coating on friction coefficient and shear bond strength of steel orthodontic brackets.

    Science.gov (United States)

    Arash, Valiollah; Anoush, Keivan; Rabiee, Sayed Mahmood; Rahmatei, Manuchehr; Tavanafar, Saeid

    2015-01-01

    Aims of the present study was to measure frictional resistance between silver coated brackets and different types of arch wires, and shear bond strength of these brackets to the tooth. In an experimental clinical research 28 orthodontic brackets (standard, 22 slots) were coated with silver ions using electroplate method. Six brackets (coated: 3, uncoated: 3) were evaluated with Scanning Electron Microscopy and Atomic Force Microscopy. The amount of friction in 15 coated brackets was measured with three different kinds of arch wires (0.019 × 0.025-in stainless steel [SS], 0.018-in stainless steel [SS], 0.018-in Nickel-Titanium [Ni-Ti]) and compared with 15 uncoated steel brackets. In addition, shear bond strength values were compared between 10 brackets with silver coating and 10 regular brackets. Universal testing machine was used to measure shear bond strength and the amount of friction between the wires and brackets. SPSS 18 was used for data analysis with t-test. SEM and AFM results showed deposition of a uniform layer of silver, measuring 8-10 μm in thickness on bracket surfaces. Silver coating led to higher frictional forces in all the three types of arch wires, which was statistically significant in 0.019 × 0.025-in SS and 0.018-in Ni-Ti, but it did not change the shear bond strength significantly. Silver coating with electroplating method did not affect the bond strength of the bracket to enamel; in addition, it was not an effective method for decreasing friction in sliding mechanics. © Wiley Periodicals, Inc.

  8. Testing of the 3M Company ACCR Conductor

    Energy Technology Data Exchange (ETDEWEB)

    Stovall, J.P.; RIzy, D.T.; Kisner, R.A.; Deve, H.E. (3M Comp.)

    2010-09-15

    The 3M Company has developed a high-temperature low-sag conductor referred to as Aluminum- Conductor Composite-Reinforced or ACCR. The conductor uses an aluminum metal matrix material to replace the steel in conventional conductors so the core has a lower density and higher conductivity. The objective of this work is to accelerate the commercial acceptance by electric utilities of these new conductor designs by testing four representative conductor classes in controlled conditions. Overhead transmission lines use bare aluminum conductor strands wrapped around a steel core strands to transmit electricity. The typical cable is referred to as aluminum-conductor steel-reinforced (ACSR). The outer strands are aluminum, chosen for its conductivity, low weight, and low cost. The center strand is of steel for the strength required to support the weight without stretching the aluminum due to its ductility. The power density of a transmission corridor has been directly increased by increasing the voltage level. Transmission voltages have increased from 115-kV to 765- kV over the past 80 years. In the United States, further increasing the voltage level is not feasible at this point in time, so in order to further increase the power density of a transmission corridor, conductor designs that increase the current carrying capability have been examined. One of the key limiting factors in the design of a transmission line is the conductor sag which determines the clearance of the conductor above ground or underlying structures needed for electrical safety. Increasing the current carrying capability of a conductor increases the joule heating in the conductor which increases the conductor sag. A conductor designed for high-temperature and lowsag operation requires an engineered modification of the conductor materials. To make an advanced cable, the 3M Company solution has been the development of a composite conductor consisting of Nextel ceramic fibers to replace the steel core and

  9. Modified forelimb grip strength test detects aging-associated physiological decline in skeletal muscle function in male mice.

    Science.gov (United States)

    Takeshita, Hikari; Yamamoto, Koichi; Nozato, Satoko; Inagaki, Tadakatsu; Tsuchimochi, Hirotsugu; Shirai, Mikiyasu; Yamamoto, Ryohei; Imaizumi, Yuki; Hongyo, Kazuhiro; Yokoyama, Serina; Takeda, Masao; Oguro, Ryosuke; Takami, Yoichi; Itoh, Norihisa; Takeya, Yasushi; Sugimoto, Ken; Fukada, So-Ichiro; Rakugi, Hiromi

    2017-02-08

    The conventional forelimb grip strength test is a widely used method to assess skeletal muscle function in rodents; in this study, we modified this method to improve its variability and consistency. The modified test had lower variability among trials and days than the conventional test in young C57BL6 mice, especially by improving the variabilities in male. The modified test was more sensitive than the conventional test to detect a difference in motor function between female and male mice, or between young and old male mice. When the modified test was performed on male mice during the aging process, reduction of grip strength manifested between 18 and 24 months of age at the group level and at the individual level. The modified test was similar to the conventional test in detecting skeletal muscle dysfunction in young male dystrophic mice. Thus, the modified forelimb grip strength test, with its improved validity and reliability may be an ideal substitute for the conventional method.

  10. EFFECT OF SODIUM HYDROXIDE CONCENTRATION ON FRESH PROPERTIES AND COMPRESSIVE STRENGTH OF SELF-COMPACTING GEOPOLYMER CONCRETE

    Directory of Open Access Journals (Sweden)

    FAREED AHMED MEMON

    2013-02-01

    Full Text Available This paper reports the results of the laboratory tests conducted to investigate the effect of sodium hydroxide concentration on the fresh properties and compressive strength of self-compacting geopolymer concrete (SCGC. The experiments were conducted by varying the concentration of sodium hydroxide from 8 M to 14 M. Test methods such as Slump flow, V-Funnel, L-box and J-Ring were used to assess the workability characteristics of SCGC. The test specimens were cured at 70°C for a period of 48 hours and then kept in room temperature until the day of testing. Compressive strength test was carried out at the ages of 1, 3, 7 and 28 days. Test results indicate that concentration variation of sodium hydroxide had least effect on the fresh properties of SCGC. With the increase in sodium hydroxide concentration, the workability of fresh concrete was slightly reduced; however, the corresponding compressive strength was increased. Concrete samples with sodium hydroxide concentration of 12 M produced maximum compressive strength.

  11. Effects of Different Radiation Doses on the Bond Strengths of Two Different Adhesive Systems to Enamel and Dentin.

    Science.gov (United States)

    da Cunha, Sandra Ribeiro de Barros; Ramos, Pedro Augusto Minorin Mendes; Haddad, Cecília Maria Kalil; da Silva, João Luis Fernandes; Fregnani, Eduardo Rodrigues; Aranha, Ana Cecília Corrêa

    2016-01-01

    To evaluate the effects of three different radiation doses on the bond strengths of two different adhesive systems to enamel and dentin. Eighty human third molars were randomly divided into four groups (n = 20) according to the radiation dose (control/no radiation, 20 Gy, 40 Gy, and 70 Gy). The teeth were sagittally sectioned into three slices: one mesial and one distal section containing enamel and one middle section containing dentin. The sections were then placed in the enamel and dentin groups, which were further divided into two subgroups (n = 10) according to the adhesive used. Three restorations were performed in each tooth (one per section) using Adper Single Bond 2 (3M ESPE) or Universal Single Bond (3M ESPE) adhesive system and Filtek Z350 XT (3M ESPE) resin composite and subjected to the microshear bond test. Data were analyzed using a two-way ANOVA followed by Tukey's test. Failure modes were examined under a stereoscopic loupe. Radiotherapy did not affect the bond strengths of the adhesives to either enamel or dentin. In dentin, the Universal Single Bond adhesive system showed higher bond strength values when compared with the Adper Single Bond adhesive system. More adhesive failures were observed in the enamel for all radiation doses and adhesives. Radiotherapy did not influence the bond strength to enamel or dentin, irrespective of the adhesive or radiation dose used.

  12. Structural Testing of a 6m Hypersonic Inflatable Aerodynamic Decelerator System

    Science.gov (United States)

    Swanson, G. T.; Kazemba, C. D.; Johnson, R. K.; Hughes, S. J.; Calomino, A. M.

    2015-01-01

    NASA is developing low ballistic coefficient technologies to support the Nations long-term goal of landing humans on Mars. Current entry, decent, and landing technologies are not practical for this class of payloads due to geometric constraints dictated by current and future launch vehicle fairing limitations. Hypersonic Inflatable Aerodynamic Decelerators (HIADs) are being developed to circumvent this limitation and are now considered a leading technology to enable landing of heavy payloads on Mars. At the beginning of 2014, a 6m diameter HIAD inflatable structure with an integrated flexible thermal protection system (TPS) was subjected to a static load test series to verify its structural performance under flight-relevant loads. The inflatable structure was constructed into a 60 degree sphere-cone configuration using nine inflatable torus segments composed of fiber-reinforced thin films. The inflatable tori were joined together using adhesives and high-strength textile woven structural straps. These straps help distribute the load throughout the inflatable structure. The 6m flexible TPS was constructed using multiple layers of high performance materials that are designed to protect the inflatable structure from heat loads that would be seen in flight during atmospheric entry. A custom test fixture was constructed to perform the static load test series. The fixture consisted of a round structural tub with enough height and width to allow for displacement of the HIAD test article as loads were applied. The bottom of the tub rim had an airtight seal with the floor. The rigid centerbody of the HIAD was mounted to a pedestal in the center of the structural tub. Using an impermeable membrane draped over the HIAD test article, an airtight seal was created with the top rim of the static load tub. This seal allowed partial vacuum to be pulled beneath the HIAD resulting in a uniform static pressure load applied to the outer surface. Using this technique, the test article

  13. Chronic effects of strength training vs. Hydro aerobics on functional and cardiorespiratory ability in postmenopausal women.

    Science.gov (United States)

    Novaes, Giovanni S; Novaes, Jefferson S; Vilaça-Alves, José; Silva, Gabriel Costa E; Garrido, Nuno D; Furtado, Hélio; Reis, Victor M

    2014-09-29

    The current study aimed to compare the effects of two exercise programs (Strength Training and Hydro Gymnastics) on the functional and cardiorespiratory abilities of Portuguese postmenopausal women. The study population consisted of 38 volunteers (age: 66.9 ± 6.1 years, body mass: 73.70 ± 10.38 kg, and body height: 1.55 ± 0.10 m). Subjects were randomly divided into two experimental groups and one control group: one group performed 24 weeks of strength training (GST; n = 14), another performed 24 weeks of hydro gymnastics (GH; n = 17) and a control group (CG; n = 7), where the subjects continued with their regular daily activities without involvement in any physical exercise program. Three assessments were performed: before the beginning of the program, 12 weeks after the start of the training program and 24 weeks after the start of the program. To assess the functional ability of the participants, several tests proposed by Jones and Rikli (2002) were performed. To evaluate the cardiorespiratory ability of the participants, a modified treadmill Bruce test was applied. Significant differences (ptraining methods in the tests, which primarily demanded muscular strength. Body mass and the body mass index showed significant differences during the three stages of assessment in the GST group (pfunctional and cardiorespiratory abilities of Portuguese postmenopausal women.

  14. Shear punch and microhardness tests for strength and ductility measurements

    International Nuclear Information System (INIS)

    Lucas, G.E.; Odette, G.R.; Sheckherd, J.W.

    1983-01-01

    In response to the requirements of the fusion reactor materials development program for small-scale mechanical property tests, two techniques have been developed, namely ball microhardness and shear punch tests. The ball microhardness test is based on the repeated measurement at increasing loads of the chordal diameter of an impression made by a spherical penetrator. A correlation has been developed to predict the constitutive relation of the test material from these data. In addition, the indentation pile-up geometry can be analyzed to provide information on the homogeneity of plastic flow in the test material. The shear punch test complements the microhardness test. It is based on blanking a circular disk from a fixed sheet metal specimen. The test is instrumented to provide punch load-displacement data, and these data can be used to determine flow properties of the test material such as yield stress, ultimate tensile strength, work-hardening exponent, and reduction of area

  15. The influence of main bar corrosion on bond strength in selfcompacting concrete

    Science.gov (United States)

    Ayop, S. S.; Emhemed, A. N. K.; Jamaluddin, N.; Sadikin, A.

    2017-11-01

    The experimental study was conducted to determine the influence of main bar corrosion on bond strength in self-compacting concrete (SCC). A total 16 tension pullout tests specimens reinforced with 10 mm and 14 mm diameter bar were used for the bond strength test. The properties of SCC were determined from the slump flow, T50cm, V-funnel and L box test. Reinforcing bars in the concrete were submitted to impressed current to accelerate the corrosion of the bar. It was found that the relationship between bond strength and concrete strength in un-corroded specimens differed from that of corroded specimens set in high-strength concrete because of brittleness in the corroded specimens, which caused a sudden loss of bond strength. The results revealed that specimens of un-corroded and corroded showed a higher percentage of bond strength degradation during the pullout tests.

  16. Strength and deformability of hollow concrete blocks: correlation of block and cylindrical sample test results

    Directory of Open Access Journals (Sweden)

    C. S. Barbosa

    Full Text Available This paper deals with correlations among mechanical properties of hollow blocks and those of concrete used to make them. Concrete hollow blocks and test samples were moulded with plastic consistency concrete, to assure the same material in all cases, in three diferente levels of strength (nominally 10 N/mm², 20 N/mm² and 30 N/mm². The mechanical properties and structural behaviour in axial compression and tension tests were determined by standard tests in blocks and cylinders. Stress and strain analyses were made based on concrete’s modulus of elasticity obtained in the sample tests as well as on measured strain in the blocks’ face-shells and webs. A peculiar stress-strain analysis, based on the superposition of effects, provided an estimation of the block load capacity based on its deformations. In addition, a tentative method to preview the block deformability from the concrete mechanical properties is described and tested. This analysis is a part of a broader research that aims to support a detailed structural analysis of blocks, prisms and masonry constructions.

  17. Combined strength and endurance training in competitive swimmers.

    Science.gov (United States)

    Aspenes, Stian; Kjendlie, Per-Ludvik; Hoff, Jan; Helgerud, Jan

    2009-01-01

    A combined intervention of strength and endurance training is common practice in elite swimming training, but the scientific evidence is scarce. The influences between strength and endurance training have been investigated in other sports but the findings are scattered. Some state the interventions are negative to each other, some state there is no negative relationship and some find bisected and supplementary benefits from the combination when training is applied appropriately. The aim of this study was to investigate the impact of a combined intervention among competitive swimmers. 20 subjects assigned to a training intervention group (n = 11) or a control group (n = 9) from two different teams completed the study. Anthropometrical data, tethered swimming force, land strength, performance in 50m, 100m and 400m, work economy, peak oxygen uptake, stroke length and stroke rate were investigated in all subjects at pre- and post-test. A combined intervention of maximal strength and high aerobic intensity interval endurance training 2 sessions per week over 11 weeks in addition to regular training were used, while the control group continued regular practice with their respective teams. The intervention group improved land strength, tethered swimming force and 400m freestyle performance more than the control group. The improvement of the 400m was correlated with the improvement of tethered swimming force in the female part of the intervention group. No change occurred in stroke length, stroke rate, performance in 50m or 100m, swimming economy or peak oxygen uptake during swimming. Two weekly dry-land strength training sessions for 11 weeks increase tethered swimming force in competitive swimmers. This increment further improves middle distance swimming performance. 2 weekly sessions of high- intensity interval training does not improve peak oxygen uptake compared with other competitive swimmers. Key pointsTwo weekly sessions of dry land strength training improves the

  18. Baseline strength can influence the ability of salivary free testosterone to predict squat and sprinting performance.

    Science.gov (United States)

    Crewther, Blair T; Cook, Christian J; Gaviglio, Chris M; Kilduff, Liam P; Drawer, Scott

    2012-01-01

    The objective of this study was to determine if salivary free testosterone can predict an athlete's performance during back squats and sprints over time and the influence baseline strength on this relationship. Ten weight-trained male athletes were divided into 2 groups based on their 1 repetition maximum (1RM) squats, good squatters (1RM > 2.0 × body weight, n = 5) and average squatters (1RM squat 1RM and 10-m sprint times on 10 separate occasions over a 40-day period. A saliva sample was collected before testing and assayed for free testosterone and cortisol. The pooled testosterone correlations were strong and significant in the good squatters (r = 0.92 for squats, r = -0.87 for sprints, p squats, r = -0.18 for sprints). Cortisol showed no significant correlations with 1RM squat and 10-m sprint performance, and no differences were identified between the 2 squatting groups. In summary, these results suggest that free testosterone is a strong individual predictor of squat and sprinting performance in individuals with relatively high strength levels but a poor predictor in less strong individuals. This information can assist coaches, trainers, and performance scientists working with stronger weight-trained athletes, for example, the preworkout measurement of free testosterone could indicate likely training outcomes or a readiness to train at a certain intensity level, especially if real-time measurements are made. Our results also highlight the need to separate group and individual hormonal data during the repeated testing of athletes with variable strength levels.

  19. Reactive Strength Index: A Poor Indicator of Reactive Strength?

    Science.gov (United States)

    Healy, Robin; Kenny, Ian; Harrison, Drew

    2017-11-28

    The primary aim was to assess the relationships between reactive strength measures and associated kinematic and kinetic performance variables achieved during drop jumps. A secondary aim was to highlight issues with the use of reactive strength measures as performance indicators. Twenty eight national and international level sprinters, consisting of fourteen men and women, participated in this cross-sectional analysis. Athletes performed drop jumps from a 0.3 m box onto a force platform with dependent variables contact time (CT), landing time (TLand), push-off time (TPush), flight time (FT), jump height (JH), reactive strength index (RSI, calculated as JH / CT), reactive strength ratio (RSR, calculated as FT / CT) and vertical leg spring stiffness (Kvert) recorded. Pearson's correlation test found very high to near perfect relationships between RSI and RSR (r = 0.91 to 0.97), with mixed relationships found between RSI, RSR and the key performance variables, (Men: r = -0.86 to -0.71 between RSI/RSR and CT, r = 0.80 to 0.92 between RSI/RSR and JH; Women: r = -0.85 to -0.56 between RSR and CT, r = 0.71 between RSI and JH). This study demonstrates that the method of assessing reactive strength (RSI versus RSR) may be influenced by the performance strategies adopted i.e. whether an athlete achieves their best reactive strength scores via low CTs, high JHs or a combination. Coaches are advised to limit the variability in performance strategies by implementing upper and / or lower CT thresholds to accurately compare performances between individuals.

  20. IgM rheumatoid factor removal and performance of the FTA-ABS (IgM) test in congenital syphilis.

    Science.gov (United States)

    Meyer, M P; Roditi, D; Louw, S

    1992-08-01

    To determine the performance of the FTA-ABS (IgM) test in congenital syphilis after eliminating interference by IgM rheumatoid factor (RF) and preventing competitive inhibition by IgG. The FTA-ABS (IgM) test was carried out before and after RF removal (achieved by immunoprecipitation of the IgG) in infants with congenital syphilis and controls. Newborns delivered in the Peninsula Maternal and Neonatal Services in Cape Town and infants presenting at Red Cross War Memorial Children's Hospital. Infants with congenital syphilis aged 0-4 months were divided into those with clinical signs at presentation and those who were asymptomatic at delivery. In addition, patients without congenital syphilis but with similar clinical signs at presentation were investigated as were control infants. The diagnosis of congenital syphilis was based on the criteria suggested by Kaufman et al (1977). Amongst symptomatic infants with congenital syphilis the FTA-ABS (IgM) test was positive in 34 (92%) of 37 cases prior to abolishing the RF effect and in 29 (78.4%) of 37 cases afterwards (p = 0.19). In 12 cases of congenital syphilis who were asymptomatic at birth, 10 had positive FTA-ABS (IgM) tests before RF removal and only three had positive tests afterwards (p = 0.006). False positive tests were not found amongst 15 symptomatic infants whose clinical features mimicked those of the infants with congenital syphilis. Among 51 healthy infants the test had a false-positive rate of 2% in newborns and 13% in older infants. The false positive reactions were eradicated by IgG precipitation. Following IgG and RF removal there was an improvement in the specificity of the FTA-ABS (IgM) test but this was at the expense of a loss of sensitivity, particularly in asymptomatic newborns. For newborns, if the FTA-ABS (IgM) test was positive, the patient was likely to require treatment for congenital syphilis, regardless of whether the result was due to the presence of RF or specific IgM.

  1. Effect of surface treatment of FRC-Post on bonding strength to resin cements

    Directory of Open Access Journals (Sweden)

    Chan-Hyun Park,

    2011-03-01

    Full Text Available Objectives The purpose of this study was to evaluate the effect of surface treatment of FRC-Post on bonding strength to resin cements. Materials and Methods Pre-surface treated LuxaPost (DMG, Rely-X Fiber Post (3M ESPE and self adhesive resin cement Rely-X Unicem (3M ESPE, conventional resin cement Rely-X ARC (3M ESPE, and Rely-X Ceramic Primer (3M ESPE were used. After completing the surface treatments of the posts, posts and resin cement were placed in clear molds and photo-activation was performed. The specimens were sectioned perpendicular to the FRC-Post into 2 mm-thick segments, and push-out strength were measured. The results of bond strength value were statistically analyzed using independent samples t-test and one-way ANOVA with multiple comparisons using Scheffe's test. Results Silanization of posts affect to the bond strength in LuxaPost, and did not affect in Rely-X Fiber Post. Rely-X ARC showed higher value than Rely-X Unicem. Conclusions Silanization is needed to enhance the bond strength between LuxaPost and resin cements.

  2. Yield Strength Testing in Human Cadaver Nasal Septal Cartilage and L-Strut Constructs.

    Science.gov (United States)

    Liu, Yuan F; Messinger, Kelton; Inman, Jared C

    2017-01-01

    To our knowledge, yield strength testing in human nasal septal cartilage has not been reported to date. An understanding of the basic mechanics of the nasal septum may help surgeons decide how much of an L-strut to preserve and how much grafting is needed. To determine the factors correlated with yield strength of the cartilaginous nasal septum and to explore the association between L-strut width and thickness in determining yield strength. In an anatomy laboratory, yield strength of rectangular pieces of fresh cadaver nasal septal cartilage was measured, and regression was performed to identify the factors correlated with yield strength. To measure yield strength in L-shaped models, 4 bonded paper L-struts models were constructed for every possible combination of the width and thickness, for a total of 240 models. Mathematical modeling using the resultant data with trend lines and surface fitting was performed to quantify the associations among L-strut width, thickness, and yield strength. The study dates were November 1, 2015, to April 1, 2016. The factors correlated with nasal cartilage yield strength and the associations among L-strut width, thickness, and yield strength in L-shaped models. Among 95 cartilage pieces from 12 human cadavers (mean [SD] age, 67.7 [12.6] years) and 240 constructed L-strut models, L-strut thickness was the only factor correlated with nasal septal cartilage yield strength (coefficient for thickness, 5.54; 95% CI, 4.08-7.00; P cadaver nasal septal cartilage, L-strut thickness was significantly associated with yield strength. In a bonded paper L-strut model, L-strut thickness had a more important role in determining yield strength than L-strut width. Surgeons should consider the thickness of potential L-struts when determining the amount of cartilaginous septum to harvest and graft. NA.

  3. Increased IL-10 mRNA and IL-23 mRNA expression in multiple sclerosis: interferon-beta treatment increases IL-10 mRNA expression while reducing IL-23 mRNA expression

    DEFF Research Database (Denmark)

    Krakauer, M.; Sorensen, P.; Khademi, M.

    2008-01-01

    volunteers served to confirm initial findings. mRNA was analyzed by real-time reverse transcriptase polymerase chain reaction (PCR). RESULTS: We found elevated expression of interleukin (IL)-23 and IL-10 in untreated MS patients. IFN-beta therapy increased IL-10 and decreased IL-23 expression independently...... of the regulatory cytokine IL-10. The elevated IL-23 mRNA levels in MS patients are noteworthy in view of the newly discovered IL-23-driven Th17 T-cell subset, which is crucial in animal models of MS. Since IFN-beta therapy resulted in decreased IL-23 mRNA levels, the Th17 axis could be another target of IFN...

  4. An Investigation Into the Relationship Between Maximum Isometric Strength and Vertical Jump Performance.

    Science.gov (United States)

    Thomas, Christopher; Jones, Paul A; Rothwell, James; Chiang, Chieh Y; Comfort, Paul

    2015-08-01

    Research has demonstrated a clear relationship between dynamic strength and vertical jump (VJ) performance; however, the relationship of isometric strength and VJ performance has been studied less extensively. The aim of this study was to determine the relationship between isometric strength and performance during the squat jump (SJ) and countermovement jump (CMJ). Twenty-two male collegiate athletes (mean ± SD; age = 21.3 ± 2.9 years; height = 175.63 ± 8.23 cm; body mass = 78.06 ± 10.77 kg) performed isometric midthigh pulls (IMTPs) to assess isometric peak force (IPF), maximum rate of force development, and impulse (IMP) (I100, I200, and I300). Force-time data, collected during the VJs, were used to calculate peak velocity, peak force (PF), peak power (PP), and jump height. Absolute IMTP measures of IMP showed the strongest correlations with VJ PF (r = 0.43-0.64; p ≤ 0.05) and VJ PP (r = 0.38-0.60; p ≤ 0.05). No statistical difference was observed in CMJ height (0.33 ± 0.05 m vs. 0.36 ± 0.05 m; p = 0.19; ES = -0.29) and SJ height performance (0.29 ± 0.06 m vs. 0.33 ± 0.05 m; p = 0.14; ES = -0.34) when comparing stronger to weaker athletes. The results of this study illustrate that absolute IPF and IMP are related to VJ PF and PP but not VJ height. Because stronger athletes did not jump higher than weaker athletes, dynamic strength tests may be more practical methods of assessing the relationships between relative strength levels and dynamic performance in collegiate athletes.

  5. Evaluation of susceptibility of high strength steels to delayed fracture by using cyclic corrosion test and slow strain rate test

    International Nuclear Information System (INIS)

    Li Songjie; Zhang Zuogui; Akiyama, Eiji; Tsuzaki, Kaneaki; Zhang Boping

    2010-01-01

    To evaluate susceptibilities of high strength steels to delayed fracture, slow strain rate tests (SSRT) of notched bar specimens of AISI 4135 with tensile strengths of 1300 and 1500 MPa and boron-bearing steel with 1300 MPa have been performed after cyclic corrosion test (CCT). During SSRT the humidity around the specimen was kept high to keep absorbed diffusible hydrogen. The fracture stresses of AISI 4135 steels decreased with increment of diffusible hydrogen content which increased with CCT cycles. Their delayed fracture susceptibilities could be successfully evaluated in consideration of both influence of hydrogen content on mechanical property and hydrogen entry.

  6. Evaluation of susceptibility of high strength steels to delayed fracture by using cyclic corrosion test and slow strain rate test

    Energy Technology Data Exchange (ETDEWEB)

    Li Songjie [School of Materials Science and Engineering, University of Science and Technology Beijing, No. 30 Xueyuan Road, Hidian Zone, Beijing 100083 (China); Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Zhang Zuogui [Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Akiyama, Eiji [Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan)], E-mail: AKIYAMA.Eiji@nims.go.jp; Tsuzaki, Kaneaki [Structural Metals Center, National Institute for Materials Science, 1-2-1 Sengen, Tsukuba, Ibaraki 305-0047 (Japan); Zhang Boping [School of Materials Science and Engineering, University of Science and Technology Beijing, No. 30 Xueyuan Road, Hidian Zone, Beijing 100083 (China)

    2010-05-15

    To evaluate susceptibilities of high strength steels to delayed fracture, slow strain rate tests (SSRT) of notched bar specimens of AISI 4135 with tensile strengths of 1300 and 1500 MPa and boron-bearing steel with 1300 MPa have been performed after cyclic corrosion test (CCT). During SSRT the humidity around the specimen was kept high to keep absorbed diffusible hydrogen. The fracture stresses of AISI 4135 steels decreased with increment of diffusible hydrogen content which increased with CCT cycles. Their delayed fracture susceptibilities could be successfully evaluated in consideration of both influence of hydrogen content on mechanical property and hydrogen entry.

  7. Relationship between test of postural control and strength and ability tests in basketball players. [Relación entre las pruebas de control postural y las pruebas de fuerza y habilidad en jugadores de baloncesto].

    Directory of Open Access Journals (Sweden)

    Abbas Asadi

    2018-04-01

    Full Text Available Abstract This study investigated the relationship between performance tests (i.e., jumping ability, strength, sprint and change of direction ability and dynamic postural control in young basketball players. Twenty-three young basketball players participated in this study and performed measurements of dynamic balance (Star Excursion Balance Test [SEBT], countermovement jump (CMJ, broad long jump (BLJ, 4×9-m shuttle run, agility T test (TT, Illinois agility test (IAT, 20-m sprint and lower extremity muscle strength. Significant association was observed between balance (at medial direction and strength performance (r = 0.523, p < 0.05. Significant positive correlations were detected between directions of SEBT and BLJ (r = -0.466 to -0.479, p < 0.05, 4×9-m shuttle run (r = -0.403 to 0.486, p < 0.05, TT (r = -0.410, p < 0.05, IAT (r = 0.435, p < 0.05 and sprint (r = -0.402 to 0.452, p < 0.05. Postural control is more in relation to change of direction ability, sprint and power performance in basketball athletes. Resumen Este estudio investigó la relación entre las pruebas de rendimiento y el control postural dinámico en jóvenes jugadores de baloncesto. Veintitrés jóvenes jugadores de baloncesto participaron en este estudio y realizaron mediciones de equilibrio dinámico (Prueba de Balance de Excursión Estrella [SEBT], salto de contramovimiento (CMJ, salto largo en longitud (BLJ, lanzamiento de 4 × 9 m, test T de agilidad (TT, prueba de agilidad de Illinois (IAT, sprint de 20 m y fuerza muscular de las extremidades inferiores. Se observó una asociación significativa entre el equilibrio (en la dirección medial y el rendimiento de la fuerza (r = 0.523, p <0.05. Se detectaron correlaciones positivas significativas entre las direcciones de SEBT y BLJ (r = -0,466 a -0,479, p <0,05, carrera con cambios de sentido de 4 × 9 m (r = -0,403 a 0,486, p <0,05, TT (r = 0,410, p <0,05, IAT (r = 0,435, p <0,05 y sprint (r = -0,402 a 0,452, p <0,05. El

  8. Modification of Bonding Strength Test of WC HVOF Thermal Spray Coating on Rocket Nozzle

    Directory of Open Access Journals (Sweden)

    Bondan Sofyan

    2010-10-01

    Full Text Available One way to reduce structural weight of RX-100 rocket is by modifying the nozzle material and processing. Nozzle is the main target in weight reduction due to the fact that it contributes 30 % to the total weight of the structur. An alternative for this is by substitution of massive graphite, which is currently used as thermal protector in the nozzle, with thin layer of HVOF (High Velocity Oxy-Fuel thermal spray layer. This paper presents the characterization of nozzle base material as well as the modification of bonding strength test, by designing additional jig to facilitate testing processes while maintaining level of test accuracy. The results showed that the material used for  RX-100 rocket nozzle is confirmed to be S45C steel. Modification of the bonding strength test was conducted by utilizing chains, which improve test flexibility and maintains level of accuracy of the test.

  9. Degradation in PV Encapsulation Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David; Annigoni, Eleonora; Ballion, Amal; Bokria, Jayesh G.; Bruckman, Laura S.; Burns, David M.; Chen, Xinxin; Feng, Jiangtao; French, Roger H.; Fowler, Sean; Honeker, Christian C.; Kempe, Michael; Khonkar, Hussam; Kohl, Michael; Perret-Aebi, Laure-Emmanuelle; Phillips, Nancy H.; Scott, Kurt P.; Sculati-Meillaud, Fanny; Wohlgemuth, John

    2016-06-06

    Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.

  10. Familiarization, validity and smallest detectable difference of the isometric squat test in evaluating maximal strength.

    Science.gov (United States)

    Drake, David; Kennedy, Rodney; Wallace, Eric

    2018-02-06

    Isometric multi-joint tests are considered reliable and have strong relationships with 1RM performance. However, limited evidence is available for the isometric squat in terms of effects of familiarization and reliability. This study aimed to assess, the effect of familiarization, stability reliability, determine the smallest detectible difference, and the correlation of the isometric squat test with 1RM squat performance. Thirty-six strength-trained participants volunteered to take part in this study. Following three familiarization sessions, test-retest reliability was evaluated with a 48-hour window between each time point. Isometric squat peak, net and relative force were assessed. Results showed three familiarizations were required, isometric squat had a high level of stability reliability and smallest detectible difference of 11% for peak and relative force. Isometric strength at a knee angle of ninety degrees had a strong significant relationship with 1RM squat performance. In conclusion, the isometric squat is a valid test to assess multi-joint strength and can discriminate between strong and weak 1RM squat performance. Changes greater than 11% in peak and relative isometric squat performance should be considered as meaningful in participants who are familiar with the test.

  11. Development and Testing of an ISRU Soil Mechanics Vacuum Test Facility

    Science.gov (United States)

    Kleinhenz, Julie E.; Wilkinson, R. Allen

    2014-01-01

    For extraterrestrial missions, earth based testing in relevant environments is key to successful hardware development. This is true for both early component level development and system level integration. For In-Situ Resource Utilization (ISRU) on the moon, hardware must interface with the surface material, or regolith, in a vacuum environment. A relevant test environment will therefore involve a vacuum chamber with a controlled, properly conditioned bed of lunar regolith simulant. However, in earth-based granular media, such as lunar regolith simulant, gases trapped within the material pore structures and water adsorbed to all particle surfaces will release when exposed to vacuum. Early vacuum testing has shown that this gas release can occur violently, which loosens and weakens the simulant, altering the consolidation state. A mid-size chamber (3.66 m tall, 1.5 m inner diameter) at the NASA Glenn Research Center has been modified to create a soil mechanics test facility. A 0.64 m deep by 0.914 m square metric ton bed of lunar simulant was placed under vacuum using a variety of pumping techniques. Both GRC-3 and LHT-3M simulant types were used. Data obtained from an electric cone penetrometer can be used to determine strength properties at vacuum including: cohesion, friction angle, bulk density and shear modulus. Simulant disruptions, caused by off-gassing, affected the strength properties, but could be mitigated by reducing pump rate. No disruptions were observed at pressures below 2.5 Torr, regardless of the pump rate. The slow off-gassing of the soil at low pressure lead to long test times; a full week to reach 10(exp -5) Torr. Robotic soil manipulation would enable multiple ISRU hardware test within the same vacuum cycle. The feasibility of a robotically controlled auger and tamper was explored at vacuum conditions.

  12. COMBINED STRENGTH AND ENDURANCE TRAINING IN COMPETITIVE SWIMMERS

    Directory of Open Access Journals (Sweden)

    Stian Aspenes

    2009-09-01

    Full Text Available A combined intervention of strength and endurance training is common practice in elite swimming training, but the scientific evidence is scarce. The influences between strength and endurance training have been investigated in other sports but the findings are scattered. Some state the interventions are negative to each other, some state there is no negative relationship and some find bisected and supplementary benefits from the combination when training is applied appropriately. The aim of this study was to investigate the impact of a combined intervention among competitive swimmers. 20 subjects assigned to a training intervention group (n = 11 or a control group (n = 9 from two different teams completed the study. Anthropometrical data, tethered swimming force, land strength, performance in 50m, 100m and 400m, work economy, peak oxygen uptake, stroke length and stroke rate were investigated in all subjects at pre- and post-test. A combined intervention of maximal strength and high aerobic intensity interval endurance training 2 sessions per week over 11 weeks in addition to regular training were used, while the control group continued regular practice with their respective teams. The intervention group improved land strength, tethered swimming force and 400m freestyle performance more than the control group. The improvement of the 400m was correlated with the improvement of tethered swimming force in the female part of the intervention group. No change occurred in stroke length, stroke rate, performance in 50m or 100m, swimming economy or peak oxygen uptake during swimming. Two weekly dry-land strength training sessions for 11 weeks increase tethered swimming force in competitive swimmers. This increment further improves middle distance swimming performance. 2 weekly sessions of high- intensity interval training does not improve peak oxygen uptake compared with other competitive swimmers

  13. Residual strength and crack propagation tests on C-130 airplane center wings with service-imposed fatigue damage

    Science.gov (United States)

    Snider, H. L.; Reeder, F. L.; Dirkin, W. J.

    1972-01-01

    Fourteen C-130 airplane center wings, each containing service-imposed fatigue damage resulting from 4000 to 13,000 accumulated flight hours, were tested to determine their fatigue crack propagation and static residual strength characteristics. Eight wings were subjected to a two-step constant amplitude fatigue test prior to static testing. Cracks up to 30 inches long were generated in these tests. Residual static strengths of these wings ranged from 56 to 87 percent of limit load. The remaining six wings containing cracks up to 4 inches long were statically tested as received from field service. Residual static strengths of these wings ranged from 98 to 117 percent of limit load. Damage-tolerant structural design features such as fastener holes, stringers, doublers around door cutouts, and spanwise panel splices proved to be effective in retarding crack propagation.

  14. Ultrasound transmission measurements for tensile strength evaluation of tablets.

    Science.gov (United States)

    Simonaho, Simo-Pekka; Takala, T Aleksi; Kuosmanen, Marko; Ketolainen, Jarkko

    2011-05-16

    Ultrasound transmission measurements were performed to evaluate the tensile strength of tablets. Tablets consisting of one ingredient were compressed from dibasic calcium phosphate dehydrate, two grades of microcrystalline cellulose and two grades of lactose monohydrate powders. From each powder, tablets with five different tensile strengths were directly compressed. Ultrasound transmission measurements were conducted on every tablet at frequencies of 2.25 MHz, 5 MHz and 10 MHz and the speed of sound was calculated from the acquired waveforms. The tensile strength of the tablets was determined using a diametrical mechanical testing machine and compared to the calculated speed of sound values. It was found that the speed of sound increased with the tensile strength for the tested excipients. There was a good correlation between the speed of sound and tensile strength. Moreover, based on the statistical tests, the groups with different tensile strengths can be differentiated from each other by measuring the speed of sound. Thus, the ultrasound transmission measurement technique is a potentially useful method for non-destructive and fast evaluation of the tensile strength of tablets. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Effects of neck strength training on isometric neck strength in rugby union players.

    Science.gov (United States)

    Geary, Kevin; Green, Brian S; Delahunt, Eamonn

    2014-11-01

    To investigate the effectiveness of a neck strengthening program on the isometric neck strength profile of male rugby union players. Controlled laboratory study. Professional rugby union club. Fifteen professional and 10 semiprofessional rugby union players. The 15 professional players undertook a 5-week neck strengthening intervention, which was performed twice per week, whereas the 10 semiprofessional players acted as the control group. Isometric strength of the neck musculature was tested using a hand-held dynamometer, for flexion (F), extension (E), left-side flexion (LSF), and right-side flexion (RSF). Preintervention and postintervention evaluations were undertaken. No significant between-group differences in isometric neck strength were noted preintervention. A significant main effect for time was observed (P isometric neck strength in all planes after the 5-week intervention (F preintervention = 334.45 ± 39.31 N vs F postintervention 396.05 ± 75.55 N; E preintervention = 606.19 ± 97.34 vs E postintervention = 733.88 ± 127.16 N; LSF preintervention = 555.56 ± 88.34 N vs LSF postintervention = 657.14 ± 122.99 N; RSF preintervention = 570.00 ± 106.53 N vs RSF postintervention = 668.00 ± 142.18 N). No significant improvement in neck strength was observed for control group participants. The results of the present study indicate that a 5-week neck strengthening program improves isometric neck strength in rugby union players, which may have implications for injury prevention, screening, and rehabilitation. The strengthening program described in the present study may facilitate rehabilitation specialists in the development of neck injury prevention, screening, and rehabilitation protocols.

  16. Biaxial flexural strength of Turkom-Cera core compared to two other all-ceramic systems

    Directory of Open Access Journals (Sweden)

    Bandar Mohammed Abdullah Al-Makramani

    2010-12-01

    Full Text Available Advances in all-ceramic systems have established predictable means of providing metal-free aesthetic and biocompatible materials. These materials must have sufficient strength to be a practical treatment alternative for the fabrication of crowns and fixed partial dentures. OBJECTIVES: The aim of this study was to compare the biaxial flexural strength of three core ceramic materials. MATERIAL AND METHODS: Three groups of 10 disc-shaped specimens (16 mm diameter x 1.2 mm thickness - in accordance with ISO-6872, 1995 were made from the following ceramic materials: Turkom-Cera Fused Alumina [(Turkom-Ceramic (M Sdn Bhd, Puchong, Selangor, Malaysia], In-Ceram (Vita Zahnfabrik, Bad Säckingen, Baden-Württemberg, Germany and Vitadur-N (Vita Zahnfabrik, Bad Säckingen, Baden-Württemberg, Germany, which were sintered according to the manufacturer's recommendations. The specimens were subjected to biaxial flexural strength test in an universal testing machine at a crosshead speed of 0.5 mm/min. The definitive fracture load was recorded for each specimen and the biaxial flexural strength was calculated from an equation in accordance with ISO-6872. RESULTS: The mean biaxial flexural strength values were: Turkom-Cera: 506.8±87.01 MPa, In-Ceram: 347.4±28.83 MPa and Vitadur-N: 128.7±12.72 MPa. The results were analyzed by the Levene's test and Dunnett's T3 post-hoc test (SPSS software V11.5.0 for Windows, SPSS, Chicago, IL, USA at a preset significance level of 5% because of unequal group variances (P<0.001. There was statistically significant difference between the three core ceramics (P<0.05. Turkom-Cera showed the highest biaxial flexural strength, followed by In-Ceram and Vitadur-N. CONCLUSIONS: Turkom-Cera core had significantly higher flexural strength than In-Ceram and Vitadur-N ceramic core materials.

  17. Subcutaneous immunoglobulin preserves muscle strength in chronic inflammatory demyelinating polyneuropathy

    DEFF Research Database (Denmark)

    Markvardsen, Lars Høj; Harbo, Thomas; Sindrup, Søren Hein

    2014-01-01

    evaluated after 3, 6 and 12 months. Primary end-points were changes in muscle strength evaluated by isokinetic dynamometry in four affected muscle groups and a composite score of muscle performance and function tests, including Medical Research Council (MRC) score, grip strength, 40-m walking test (40-MWT......BACKGROUND AND PURPOSE: Subcutaneous immunoglobulin (SCIG) is superior to placebo treatment for maintenance of muscle strength during 12 weeks in patients with chronic inflammatory demyelinating polyneuropathy (CIDP). The present study evaluated whether SCIG preserves muscle strength for 1 year......) and nine-hole peg test (9-HPT). Secondary end-points were changes of each of the listed parameters at each time point as well as an overall disability sum score (ODSS). RESULTS: The dose of SCIG was significantly unaltered during the follow-up period. Overall the isokinetic dynamometry value increased by 7...

  18. The relationship between muscle strength, anaerobic performance, agility, sprint ability and vertical jump performance in professional basketball players.

    Science.gov (United States)

    Alemdaroğlu, Utku

    2012-03-01

    The purpose of this study was to investigate the relationship between isokinetic knee strength, anaerobic performance, sprinting ability, agility and vertical jump performance in first division basketball players. Twelve male first division basketball players participated in this study. The mean age was 25.1 ± 1.7 yrs; mean body height 194.8 ± 5.7 cm; mean body mass 92.3± 9.8 kg; mean PBF 10.1± 5.1; and mean VO2max 50.55 ± 6.7 ml/kg/min Quadriceps and hamstrings were measured at 60° and 180°/s, anaerobic performance was evaluated using the Wingate anaerobic power test, sprint ability was determined by single sprint performance (10-30 m), jump performance was evaluated by countermovement (CMJ) and squat jump (SJ) tests and agility performance was measured using the T drill agility test. Quadriceps strength was significantly correlated with peak power at all contraction velocities. However, for mean power, significant correlation was only found between the 60° left and 180° right knee quadriceps measurements. No measure of strength was significantly related to the measurements from/results of field tests. Moreover, strong relations were found between the performance of athletes in different field tests (p< 0.05). The use of correlation analysis is the limitation of the this study.

  19. Prediction of concrete strength in massive structures

    International Nuclear Information System (INIS)

    Sakamoto, T.; Makino, H.; Nakane, S.; Kawaguchi, T.; Ohike, T.

    1989-01-01

    Reinforced concrete structures of a nuclear power plant are mostly of mass concrete with cross-sectional dimensions larger than 1.0 m. The temperature of concrete inside after placement rises due to heat of hydration of cement. It is well known that concrete strengths of mass concrete structure subjected to such temperature hysteresis are generally not equal to strengths of cylinders subjected to standard curing. In order to construct a mass concrete structure of high reliability in which the specified concrete strength is satisfied by the specified age, it is necessary to have a thorough understanding of the strength gain property of concrete in the structure and its relationships with the water-cement ratio of the mix, strength of standard-cured cylinders and the internal temperature hysteresis. This report describes the result of studies on methods of controlling concrete strength in actual construction projects

  20. Superconducting microwave cavity parametric converter transducer sensitive to 10-19 M harmonic motion

    International Nuclear Information System (INIS)

    Reece, C.E.

    1984-01-01

    Toward the development of a transducer suitable for the detection of high frequency gravitational effects, a superconducting microwave coupled-cavity parametric converter transducer has been analyzed, developed and tested. An analysis is presented of the intermodal parametric conversion which is produced by harmonic perturbaton of the length of a 10 GHz TE 011 mode cylindrical resonant cavity. The converter is examined as a transducer of displacement with harmonic frequency near the intermodal difference frequency. Transducer sensitivity dependence upon cavity tunings, couplings, and Q-factors is analyzed and experimentally tested with excellent agreement. The transducer consists of two identical coupled TE 011 niobium cavities with one endwall driven into mechanical oscillation by an externally mounted piezoelectric ceramic. A displacement with effective amplitude (3.7 +/- 1.3) x 10 -19 m and frequency 1.13 MHz has been observed by detecting a 10GHz conversion power of 10 -21 watts. This measurement was obtained with 0.12 mJ stored in a cavity resonance with an unloaded Q-factor of 6.7 x 10 8 at 1.55 0 K. The applications of this device in the detection of high frequency gravitational effects are also discussed. Finally, the prospects for improvement of transducer sensitivity and the ultimate limitations are presented

  1. Four chemical methods of porcelain conditioning and their influence over bond strength and surface integrity

    Science.gov (United States)

    Stella, João Paulo Fragomeni; Oliveira, Andrea Becker; Nojima, Lincoln Issamu; Marquezan, Mariana

    2015-01-01

    OBJECTIVE: To assess four different chemical surface conditioning methods for ceramic material before bracket bonding, and their impact on shear bond strength and surface integrity at debonding. METHODS: Four experimental groups (n = 13) were set up according to the ceramic conditioning method: G1 = 37% phosphoric acid etching followed by silane application; G2 = 37% liquid phosphoric acid etching, no rinsing, followed by silane application; G3 = 10% hydrofluoric acid etching alone; and G4 = 10% hydrofluoric acid etching followed by silane application. After surface conditioning, metal brackets were bonded to porcelain by means of the Transbond XP system (3M Unitek). Samples were submitted to shear bond strength tests in a universal testing machine and the surfaces were later assessed with a microscope under 8 X magnification. ANOVA/Tukey tests were performed to establish the difference between groups (α= 5%). RESULTS: The highest shear bond strength values were found in groups G3 and G4 (22.01 ± 2.15 MPa and 22.83 ± 3.32 Mpa, respectively), followed by G1 (16.42 ± 3.61 MPa) and G2 (9.29 ± 1.95 MPa). As regards surface evaluation after bracket debonding, the use of liquid phosphoric acid followed by silane application (G2) produced the least damage to porcelain. When hydrofluoric acid and silane were applied, the risk of ceramic fracture increased. CONCLUSIONS: Acceptable levels of bond strength for clinical use were reached by all methods tested; however, liquid phosphoric acid etching followed by silane application (G2) resulted in the least damage to the ceramic surface. PMID:26352845

  2. HYBRID CONTINUUM-DISCONTINUUM MODELLING OF ROCK FRACUTRE PROCESS IN BRAZILIAN TENSILE STRENGTH TEST

    Directory of Open Access Journals (Sweden)

    Huaming An

    2017-10-01

    Full Text Available A hybrid continuum-discontinuum method is introduced to model the rock failure process in Brazilian tensile strength (BTS test. The key component of the hybrid continuum-discontinuum method, i.e. transition from continuum to discontinuum through fracture and fragmentation, is introduced in detail. A laboratory test is conducted first to capture the rock fracture pattern in the BTS test while the tensile strength is calculated according to the peak value of the loading forces. Then the proposed method is used to model the rock behaviour during BTS test. The stress propagation is modelled and compared with those modelled by finite element method in literatures. In addition, the crack initiation and propagation are captured and compared with the facture patter in laboratory test. Moreover, the force-loading displacement curve is obtained which represents a typical brittle material failure process. Furthermore, the stress distributions along the vertical direction are compared with the theoretical solution. It is concluded that the hybrid continuum-discontinuum method can model the stress propagation process and the entire rock failure process in BTS test. The proposed method is a valuable numerical tool for studying the rock behaviour involving the fracture and fragmentation processes.

  3. Normalized knee-extension strength or leg-press power after fast-track total knee arthroplasty

    DEFF Research Database (Denmark)

    Aalund, Peter K; Larsen, Kristian; Hansen, Torben Bæk

    2013-01-01

    OBJECTIVE: (s): To investigate which of the two muscle-impairment measures for the operated leg, normalized knee extension strength or leg press power, is more closely associated to performance-based and self-reported measures of function shortly following total knee arthroplasty (TKA). DESIGN...... and dynamic leg presses to determine their body-mass normalized knee extension strength and leg press power, respectively. The 10-m fast speed walking and 30-s chair stand tests were used to determine performance-based function, while the Western Ontario McMaster University Osteoarthritis Index (WOMAC......) and Oxford Knee scores were used to determine self-reported function. RESULTS: Normalized leg press power was more closely associated to both performance-based (r=.82, P...

  4. Prediction of soil shear strength in agricultural and natural environments of the Brazilian Cerrado

    Directory of Open Access Journals (Sweden)

    Reginaldo Barboza da Silva

    2015-01-01

    Full Text Available The objective of this work was to develop uni- and multivariate models to predict maximum soil shear strength (τmax under different normal stresses (σn, water contents (U, and soil managements. The study was carried out in a Rhodic Haplustox under Cerrado (control area and under no-tillage and conventional tillage systems. Undisturbed soil samples were taken in the 0.00-0.05 m layer and subjected to increasing U and σn, in shear strength tests. The uni- and multivariate models - respectively τmax=10(a+bU and τmax=10(a+bU+cσn - were significant in all three soil management systems evaluated and they satisfactorily explain the relationship between U, σn, and τmax. The soil under Cerrado has the highest shear strength (τ estimated with the univariate model, regardless of the soil water content, whereas the soil under conventional tillage shows the highest values with the multivariate model, which were associated to the lowest water contents at the soil consistency limits in this management system.

  5. Absolute and relative reliability of isokinetic and isometric trunk strength testing using the IsoMed-2000 dynamometer.

    Science.gov (United States)

    Roth, Ralf; Donath, Lars; Kurz, Eduard; Zahner, Lukas; Faude, Oliver

    2017-03-01

    The present study aimed to assess the between day reliability of isokinetic and isometric peak torque (PT) during trunk measurement on an isokinetic device (IsoMed 2000). Test-retest-protocol on five separate days. Fifteen healthy sport students (8 female and 7 male) aged 21 to 26. PT was assessed in isometric back extension and flexion as well as right and left rotation. Isokinetic strength was captured at a speed of 60°/s and 150°/s for all tasks. For none of the assessed parameters a meaningful variation in PT during test days was observed. Relative reliability (ICC = 0.85-0.96) was excellent for all tasks. Estimates of absolute reliability as Coefficient of Variation (CoV) and Standard Error of Measurement (SEM in Nm/kg lean body mass) remained stable for isometric (6.9% strength measurement in flexion and extension or trunk rotation in either isometric or isokinetic condition is highly reliable. Therefore, it seems possible to elucidate changes which are smaller than 10% due to intervention programs when a preceding familiarization condition was applied. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Vertebral body bone strength: the contribution of individual trabecular element morphology.

    Science.gov (United States)

    Parkinson, I H; Badiei, A; Stauber, M; Codrington, J; Müller, R; Fazzalari, N L

    2012-07-01

    Although the amount of bone explains the largest amount of variability in bone strength, there is still a significant proportion unaccounted for. The morphology of individual bone trabeculae explains a further proportion of the variability in bone strength and bone elements that contribute to bone strength depending on the direction of loading. Micro-CT imaging enables measurement of bone microarchitecture and subsequently mechanical strength of the same sample. It is possible using micro-CT data to perform morphometric analysis on individual rod and plate bone trabeculae using a volumetric spatial decomposition algorithm and hence determine their contribution to bone strength. Twelve pairs of vertebral bodies (T12/L1 or L4/L5) were harvested from human cadavers, and bone cubes (10 × 10 × 10 mm) were obtained. After micro-CT imaging, a volumetric spatial decomposition algorithm was applied, and measures of individual trabecular elements were obtained. Bone strength was measured in compression, where one bone specimen from each vertebral segment was tested supero-inferiorly (SI) and the paired specimen was tested antero-posteriorly (AP). Bone volume fraction was the strongest individual determinant of SI strength (r(2) = 0.77, p body bone architecture into its constituent morphological elements shows that trabecular element morphology has specific functional roles to assist in maintaining skeletal integrity.

  7. Relationship between isometric and dynamic strength in recreationally trained men.

    Science.gov (United States)

    McGuigan, Michael R; Newton, Michael J; Winchester, Jason B; Nelson, Arnold G

    2010-09-01

    The purpose of this investigation was to examine the relationships between measures of maximal isometric force (peak force [PF]), rate of force development (RFD), vertical jump performance (VJ) and 1-repetition maximum (1RM) strength in recreationally trained men. The subjects in this study were 26 men ([mean +/- SD]: age 22 +/- 1 years; height 175 +/- 7 cm; mass 90 +/- 10 kg). They were tested for PF using the isometric midthigh pull exercise. The 1RM for the squat and bench press exercise were determined as a measure of dynamic strength. Explosive strength was measured as RFD from the isometric force-time curve. Correlations between the variables were calculated using Pearson product moment correlation coefficient. There was a nearly perfect correlation between measures of PF and 1RM squat (r = 0.97, p isometric maximum strength determined during the isometric midthigh pull test correlated well with 1RM and VJ testing. However, RFD measured during the same test did not appear to correlate as well with other measures. The isometric midthigh pull provides an efficient method for assessing strength in recreationally trained individuals. Practitioners wishing to obtain performance data related to maximum strength may wish to consider isometric testing as a less time intensive method of testing.

  8. Diagnostic PCR tests for Microsporum audouinii, M. canis and Trichophyton infections

    DEFF Research Database (Denmark)

    Brillowska-Dabrowska, Anna; Swierkowska, Aleksandra; Lindhardt Saunte, Ditte Marie

    2010-01-01

    ; 25 routine specimens from patients suspected of having dermatophytosis; 10 hair specimens from guinea pigs experimentally infected with M. canis; and two samples from un-infected control animals. DNA was prepared by a 10-min procedure from pure cultures as previously described. The 302 bp PCR product....... Finally, the Microsporum PCR was positive for 10/10 guinea pig specimens from infected animals but for 0/2 of the control animal samples. The evaluation of the two PCR tests indicated excellent sensitivity and specificity....

  9. [Effect of casein phosphopeptide-amorphouscalcium phosphate (CPP-ACP) treatment on the shear bond strength of orthodontic brackets after tooth bleaching].

    Science.gov (United States)

    Lu, Jing; Ding, Xiao-jun; Yu, Xiao-ping; Gong, Yi-ming

    2015-10-01

    To evaluate the effect of casein phosphopeptide-amorphouscalcium phosphate (CPP-ACP) treatment on the shear bond strength of orthodontic brackets after tooth bleaching. One hundred extracted human premolars were randomly divided and treated according to 5 groups (n=20) : (1) no treatment; (2) 10% carbamide peroxide bleaching; (3) 38% hydrogen peroxide bleaching; (4)10% carbamide peroxide bleaching and CPP-ACP paste; (5)38% hydrogen peroxide bleaching and CPP-ACP paste. In all groups, the brackets were bonded using a conventional acid-etch and bond system (Transbond XT, 3M Unitek, Monrovia, Calif). The shear bond strength adhesive remnant index (ARI) of the brackets were determined and the data was analyzed by ANOVA and Bonferroni test using SPSS13.0 software package. The use of 10% carbamide peroxide and 38% hydrogen peroxide bleaching significantly decreased the shear bond strength of orthodontic brackets when compared with untreated group (P0.05). The ARI did not show any significant difference before and after CPP-ACP treatment. After tooth bleaching, CPP-ACP treatment have little influence on the shear bond strength of orthodontic brackets.

  10. Comparison of two test designs for evaluating the shear bond strength of resin composite cements.

    Science.gov (United States)

    Hu, M; Weiger, R; Fischer, J

    2016-02-01

    To compare a shear bond strength test for resin composite cements developed in order to better consider the shrinkage stress (here termed "Swiss shear test") with the shear test design according to ISO 29022. Four restorative materials (VITA Enamic (VE), VITA Suprinity (VS), Vitablocs Mark II (VM) and VITA YZ T (YZ)) served as substrate. VE, VS and VM were polished or etched. YZ was polished, sandblasted or etched. Specimens were either bonded according to the Swiss or the ISO shear test. RelyX Unicem 2 Automix, Maxcem Elite and PermaFlo DC were used as cements. Shear bond strength (SBS) was measured. Failure modes (adhesive, cohesive or mixed) were evaluated by means of SEM. Mean SBS values obtained with the Swiss shear test were significantly lower than those obtained with the ISO shear test. VE and VM exhibited similar SBS, values of VS were significantly higher. On etched surfaces VM and VE exhibited primarily cohesive failures, VS primarily adhesive failures. On polished substrates significantly lower bond strength values and exclusively adhesive failures were observed. YZ exhibited solely adhesive failures. Compared to polished YZ, SBS significantly increased after sandblasting and even more after etching. Only for adhesively failed specimens mean SBS values of Swiss and ISO shear test were strongly correlated. Both test designs showed the same ranking of test results. When adhesive failure occurred test results were strongly correlated. When cohesive failure was involved, both test designs did not provide reliable results. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  11. Association between MRI-defined osteoarthritis, pain, function and strength 3-10 years following knee joint injury in youth sport.

    Science.gov (United States)

    Whittaker, Jackie L; Toomey, Clodagh M; Woodhouse, Linda J; Jaremko, Jacob L; Nettel-Aguirre, Alberto; Emery, Carolyn A

    2017-10-10

    Youth and young adults who participate in sport have an increased risk of knee injury and subsequent osteoarthritis. Improved understanding of the relationship between structural and clinical outcomes postinjury could inform targeted osteoarthritis prevention interventions. This secondary analysis examines the association between MRI-defined osteoarthritis and self-reported and functional outcomes, 3-10 years following youth sport-related knee injury in comparison to healthy controls. Participants included a subsample (n=146) of the Alberta Youth Prevention of Early Osteoarthritis cohort: specifically, 73 individuals with 3-10 years history of sport-related intra-articular knee injury and 73 age-matched, sex-matched and sport-matched controls with completed MRI studies. Outcomes included: MRI-defined osteoarthritis, radiographic osteoarthritis, Knee Injury and Osteoarthritis Outcome Score, Intermittent and Constant Osteoarthritis Pain, knee extensor/flexor strength, triple-hop and Y-balance test. Descriptive statistics and univariate logistic regression were used to compare those with and without MRI-defined osteoarthritis. Associations between MRI-defined osteoarthritis and each outcome were assessed using multivariable linear regression considering the influence of injury history, sex, body mass index and time since injury. Participant median age was 23 years (range 15-27), and 63% were female. MRI-defined osteoarthritis varied by injury history, injury type and surgical history and was not isolated to participants with ACL and/or meniscal injuries. Those with a previous knee injury had 10-fold (95% CI 2.3 to 42.8) greater odds of MRI-defined osteoarthritis than uninjured participants. MRI-defined osteoarthritis was independently significantly associated with quality of life, but not symptoms, strength or function. MRI-detected structural changes 3-10 years following youth sport-related knee injury may not dictate clinical symptomatology, strength or function

  12. Test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy.

    Science.gov (United States)

    Savva, Christos; Giakas, Giannis; Efstathiou, Michalis; Karagiannis, Christos

    2014-01-01

    The purpose of this study was to evaluate the test-retest reliability of handgrip strength measurement using a hydraulic hand dynamometer in patients with cervical radiculopathy (CR). A convenience sample of 19 participants (14 men and 5 women; mean ± SD age, 50.5 ± 12 years) with CR was measured using a Jamar hydraulic hand dynamometer by the same rater on 2 different testing sessions with an interval of 7 days between sessions. Data collection procedures followed standardized grip strength testing guidelines established by the American Society of Hand Therapists. During the repeated measures, patients were advised to rest their upper limb in the standardized arm position and encouraged to exert 3 maximum gripping efforts. The mean value of the 3 efforts (measured in kilogram force [Kgf]) was used for data analysis. The intraclass correlation coefficient, SEM, and the Bland-Altman plot were used to estimate test-retest reliability and measurement precision. Grip strength measurement in CR demonstrated an intraclass correlation coefficient of 0.976, suggesting excellent test-retest reliability. The small SEM in both testing sessions (SEM1, 2.41 Kgf; SEM2, 2.51 Kgf) as well as the narrow width of the 95% limits of agreements (95% limits of agreement, -4.9 to 4.4 Kgf) in the Bland-Altman plot reflected precise measurements of grip strength in both occasions. Excellent test-retest reliability for grip strength measurement was measured in patients with CR, demonstrating that a hydraulic hand dynamometer could be used as an outcome measure for these patients. Copyright © 2014 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  13. Laboratory testing of gneissic rocks in Olkiluoto borehole OL-KR24

    International Nuclear Information System (INIS)

    Eloranta, P.

    2006-10-01

    The stress-strain behaviour of anisotropic gneissic rocks from Olkiluoto, Finland, was studied for a total of 25 rock mechanics tests. Samples were selected from borehole OLKR24 at a depth level of 417-442 m. Tests included 15 uniaxial compression tests, 10 indirect tensile strength tests and 6 triaxial compression tests. Strain gauges were installed in five samples to evaluate the anisotropic properties, and acoustic emission sensors were installed in ten samples to estimate the stress damage levels. The specimen preparation and tests were carried out at the Laboratory of Rock Engineering, Helsinki University of Technology, Finland. Specimens were tested under laboratory-air-dry conditions and were photographed before and after the tests. The values obtained for the uniaxial compressive strength were in the range 56.5 - 165.9 MPa and for the indirect tensile strength 7.7 - 12.1 MPa. The anisotropic ratio of Young's modulus, E/E', was of the order of 1.1. (orig.)

  14. Slippage of steel in high and normal strength concrete

    International Nuclear Information System (INIS)

    Ahmed, K.; Siddiqi, Z.A.; Yousaf, M.

    2007-01-01

    Composite action of any reinforced concrete member is only possible if sufficient bond strength exists between steel reinforcing bars and concrete, which can adequately transfer shear stress between them. Bond strength is a function of compressive strength of concrete and hence high strength concrete has higher bond strength (1-2). Therefore required development length can be reduced. In order to investigate the effect of development length on bond stress and slip relationships, experimental investigation was carried out. In this experimentation 24 pull-out samples of high strength concrete and normal strength concrete were casted and tested. The results of this investigation revealed that by increasing the development length from 5db to 10db bond strength increases for both high and normal strength concrete as shown in Figure 11, 12 and 13. However in case of normal strength concrete increase in bond strength is more compared to that in high strength concrete as it is clear from Figure 11 and Figure 13. The increase in bond strength is observed even at 10db development length but the extent is less for 19 mm than 16 mm bars as shown in Figure 12 and Figure 13. This is in agreement with the earlier findings of Chen et al (3) and Harajli et al (1). However in case of HSC the total slippage at 10db is 50% greater than at 5db. This may be due to the fact that more no of concrete keys participate in resisting the slippage. (author)

  15. Experimental study on the usefulness of magnetotherapy in bone fractures (tibial osteotomy in the rat). Accumulation of 99 mTc MDP - tests of tensile strength - determination of alkaline phosphatase

    International Nuclear Information System (INIS)

    Sailer, R.

    1985-01-01

    Non-directional magnetic field therapy using a flux density of 60 G and a frequency of 25 Hz was carried out over 12 hours daily in rats in order to ascertain its influence on the healing process following osteotomy of the tibia with internal splint fixation of the fractured bone being carried out as an additional measure. The results thus achieved were compared to those seen in control animals, were no magnetotherapy was carried out, on the basis of scintiscan studies using 99 mTc MDP (degree of density in the callus formed around the fracture zone), the plasma levels of alkaline phosphatase and tests of tensile strength. The follow-up observations of the healing process were additionally based on radiological and histological evaluations of the animals. Beneficial effects of magnetotherapy on the healing process could not be confirmed with any statistical significance. (TRV) [de

  16. Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength.

    Science.gov (United States)

    Vannebo, Katrine Tranaas; Iversen, Vegard Moe; Fimland, Marius Steiro; Mork, Paul Jarle

    2018-03-02

    There is a lack of test-retest reliability studies of measurements of cervical muscle strength, taking into account gender and possible learning effects. To investigate test-retest reliability of measurement of maximal isometric cervical muscle strength by handheld dynamometry. Thirty women (age 20-58 years) and 28 men (age 20-60 years) participated in the study. Maximal isometric strength (neck flexion, neck extension, and right/left lateral flexion) was measured on three separate days at least five days apart by one evaluator. Intra-rater consistency tended to improve from day 1-2 measurements to day 2-3 measurements in both women and men. In women, the intra-class correlation coefficients (ICC) for day 2 to day 3 measurements were 0.91 (95% confidence interval [CI], 0.82-0.95) for neck flexion, 0.88 (95% CI, 0.76-0.94) for neck extension, 0.84 (95% CI, 0.68-0.92) for right lateral flexion, and 0.89 (95% CI, 0.78-0.95) for left lateral flexion. The corresponding ICCs among men were 0.86 (95% CI, 0.72-0.93) for neck flexion, 0.93 (95% CI, 0.85-0.97) for neck extension, 0.82 (95% CI, 0.65-0.91) for right lateral flexion and 0.73 (95% CI, 0.50-0.87) for left lateral flexion. This study describes a reliable and easy-to-administer test for assessing maximal isometric cervical muscle strength.

  17. Effect of curing and silanizing on composite repair bond strength using an improved micro-tensile test method.

    Science.gov (United States)

    Eliasson, Sigfus Thor; Dahl, Jon E

    2017-01-01

    Objectives: To evaluate the micro-tensile repair bond strength between aged and new composite, using silane and adhesives that were cured or left uncured when new composite was placed. Methods: Eighty Filtek Supreme XLT composite blocks and four control blocks were stored in water for two weeks and thermo-cycled. Sandpaper ground, etched and rinsed specimens were divided into two experimental groups: A, no further treatment and B, the surface was coated with bis-silane. Each group was divided into subgroups: (1) Adper Scotchbond Multi-Purpose, (2) Adper Scotchbond Multi-Purpose adhesive, (3) Adper Scotchbond Universal, (4) Clearfil SE Bond and (5) One Step Plus. For each adhesive group, the adhesive was (a) cured according to manufacturer's instructions or (b) not cured before repair. The substrate blocks were repaired with Filtek Supreme XLT. After aging, they were serially sectioned, producing 1.1 × 1.1 mm square test rods. The rods were prepared for tensile testing and tensile strength calculated at fracture. Type of fracture was examined under microscope. Results: Leaving the adhesive uncured prior to composite repair placement increased the mean tensile values statistically significant for all adhesives tested, with or without silane pretreatment. Silane surface treatment improved significantly ( p strength values for all adhesives, both for the cured and uncured groups. The mean strength of the control composite was higher than the strongest repair strength ( p strength. Not curing the adhesive before composite placement increased the tensile bond strength.

  18. 46 CFR 61.30-10 - Hydrostatic test.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Hydrostatic test. 61.30-10 Section 61.30-10 Shipping... INSPECTIONS Tests and Inspections of Fired Thermal Fluid Heaters § 61.30-10 Hydrostatic test. All new installations of thermal fluid heaters must be given a hydrostatic test of 11/2 times the maximum allowable...

  19. Effects of a whole body vibration training program on strength, power, and functional tests in the physically active elderly

    Directory of Open Access Journals (Sweden)

    Renata Gonçalves da Silva

    2009-04-01

    Full Text Available The aim of this study was to investigate the effect of a whole body vibration training program on knee extensor isokinetic peak torque, average power, and functional tests in the physically active elderly. Forty-seven subjects, who participated in a training program for the elderly, were recruited. The subjects were divided into two groups: whole body vibration group (WBV (n=24, 70.7±5.8 years, 62.7±12.3 kg and 155.9±8.0 cm and control group (n=23. 70.0±5.7 years, 65.3±10.7 kg and 157.9±6.6 cm. The WBS group underwent whole body vibration exercise and their regular training program for 13 weeks, 2 times per week, whereas the control group performed the regular training program only. Whole body vibration training was not effective in increasing isokinetic peak torque, average power, or performance in the functional tests. On the other hand, the regular training program was effective in increasing elbow flexor strength endurance, distance covered in the 6-min walk test, and speed in the timed up and go test. The results suggest that vibration training is not effective in modifying functionality or muscle strength and power in the physically active elderly.

  20. Amalgam shear bond strength to dentin using single-bottle primer/adhesive systems.

    Science.gov (United States)

    Cobb, D S; Denehy, G E; Vargas, M A

    1999-10-01

    To evaluate the in vitro shear bond strengths (SBS) of a spherical amalgam alloy (Tytin) to dentin using several single-bottle primer/adhesive systems both alone: Single Bond (SB), OptiBond Solo (Sol), Prime & Bond 2.1 (PB), One-Step (OS) and in combination with the manufacturer's supplemental amalgam bonding agent: Single Bond w/3M RelyX ARC (SBX) and Prime & Bond 2.1 w/Amalgam Bonding Accessory Kit (PBA). Two, three-component adhesive systems, Scotchbond Multi-Purpose (SBMP) and Scotchbond Multi-Purpose Plus w/light curing (S + V) and w/o light curing (S+) were used for comparison. One hundred eight extracted human third molars were mounted lengthwise in phenolic rings with acrylic resin. The proximal surfaces were ground to expose a flat dentin surface, then polished to 600 grit silicon carbide paper. The teeth were randomly assigned to 9 groups (n = 12), and dentin surfaces in each group were treated with an adhesive system according to the manufacturer's instructions, except for S + V specimens, where the adhesive was light cured for 10 s before placing the amalgam. Specimens were then secured in a split Teflon mold, having a 3 mm diameter opening and amalgam was triturated and condensed onto the treated dentin surfaces. Twenty minutes after condensation, the split mold was separated. Specimens were placed in distilled water for 24 hrs, then thermocycled (300 cycles, between 5 degrees C and 55 degrees C, with 12 s dwell time). All specimens were stored in 37 degrees C distilled water for 7 days, prior to shear strength testing using a Zwick Universal Testing Machine at a cross-head speed of 0.5 mm/min. The highest to the lowest mean dentin shear bond strength values (MPa) for the adhesive systems tested were: S + V (10.3 +/- 2.3), SBX (10.2 +/- 3.5), PBA, (6.4 +/- 3.6), SOL (5.8 +/- 2.5), SBMP (5.7 +/- 1.8), S+ (4.8 +/- 2.3), PB (2.7 +/- 2.6), SB (2.7 +/- 1.1) and OS (2.5 +/- 1.8). One-way ANOVA and Duncan's Multiple Range Test indicated significant

  1. Comparison of bond strength of different endodontic sealers to root dentin: An in vitro push-out test.

    Science.gov (United States)

    Madhuri, G Vijaya; Varri, Sujana; Bolla, Nagesh; Mandava, Pragna; Akkala, Lakshmi Swathi; Shaik, Jaheer

    2016-01-01

    To compare the bond strength of four different endodontic sealers to root dentin through push-out test design. Forty single-rooted teeth with completely formed apices were selected. Teeth were decoronated, and working length was determined. Instrumentation and irrigation were performed. The teeth were divided into four groups based upon the sealer used. Group 1: Bioceramic sealer (Endosequence), Group 2: Mineral trioxide aggregate (MTA) based sealer (MTA Fill apex), Group 3: Epoxy resin based sealer (MM-Seal), and Group 4: Dual cure resin-based sealer (Hybrid Root Seal). Manipulation and application of the sealer was done as per the manufacturer instructions. All the teeth were obturated using 6% gutta-percha. After obturation, each tooth was prepared for push-out test with root slices of 2 mm thickness using universal testing machine. The highest bond strength was found in Group 1 (Endosequence) (P strength was found in Group 2 (MTA Fill apex). Statistical analysis is done by two-way ANOVA and Newman-Keuls multiple post hoc. The push-out bond strength of Bioceramic sealer was highest followed by resin-based sealer and lowest bond strength was observed in MTA-based sealer.

  2. Precision measurement of relative oscillator strengths

    International Nuclear Information System (INIS)

    Blackwell, D.E.; Ibbetson, P.A.; Petford, A.D.; Shallis, M.J.

    1979-01-01

    The accuracy of the Oxford method of comparing oscillator strengths has been improved by a factor of 10 to 0.5 per cent (0.002 dex) for low excitation lines. The improvements made to the apparatus are briefly described and its new performance discussed. A test for LTE in the furnace is also described. Relative oscillator strengths for 60 lines of Fe I with excitation potentials between 0.00 and 0.12 eV are given. Those with lambda > 320 nm have an accuracy of 0.5 per cent, and those with lambda < 320 nm have an accuracy of 1.0 per cent. Absolute values with an accuracy of 2.5 per cent for all lines are given. (author)

  3. Efeitos da suplementação de creatina na força máxima e na amplitude do eletromiograma de mulheres fisicamente ativas Effect of creatine supplementation in maximal strength and electromyogram amplitude of physically active women

    Directory of Open Access Journals (Sweden)

    Rômulo José Dantas Medeiros

    2010-10-01

    Full Text Available A suplementação de creatina apresenta ação ergogênica na força muscular. Entretanto, não há consenso deste efeito na força isométrica máxima e na amplitude do eletromiograma (EMG. Assim, o objetivo deste estudo foi analisar os efeitos da suplementação de creatina na força isométrica máxima e na amplitude do EMG em mulheres fisicamente ativas. Vinte e sete mulheres (idade 23,04 ± 1,82 anos, massa corporal 58,37 ± 6,10kg, estatura 1,63 ± 0,05m e índice de massa corporal 21,93 ± 2,02kg/m² foram designadas aleatoriamente para os grupos creatina (GCr (n = 13 e placebo (GPL (n = 14, os quais ingeriram diariamente, durante seis dias, 20g de creatina mono-hidratada e 20g de maltodextrina, respectivamente. Antes e depois da suplementação, a força foi medida em um dinamômetro isométrico durante contração isométrica voluntária máxima (CIVM de extensão unilateral do joelho (três séries de 6s intervaladas por 180s, com captação simultânea dos valores root mean square (RMS do EMG obtido no músculo vasto lateral. A ANOVA de dois critérios de classificação (dois momentos x dois grupos e o teste de Wilcoxon foram utilizados na análise estatística dos dados paramétricos e não paramétricos (p Creatine supplementation has shown to enhance muscular strength. However, there is not a consensus on this effect on maximal isometric strength neither on electromyogram (EMG amplitude. Thus, the aim of this study was to analyze the creatine supplementation effects on maximal isometric strength and EMG amplitude in physically active women. 27 women (age 23.04 ± 1.82 years, body mass 58.37 ± 6.10kg, height 1.63±0.05m and body mass index 21.93 ± 2.02kg/m² were randomly assigned in creatine (CrG (n = 13 or placebo group (PLG (n = 14. The CrG and PLG ingested 20g/day of creatine and 20g/day of maltodextrin during six days, respectively. The strength was measured before and after supplementation using a isometric dynamometer

  4. Optimum concrete compression strength using bio-enzyme

    Directory of Open Access Journals (Sweden)

    Bagio Tony Hartono

    2017-01-01

    Full Text Available To make concrete with high compressive strength and has a certain concrete specifications other than the main concrete materials are also needed concrete mix quality control and other added material is also in line with the current technology of concrete mix that produces concrete with specific characteristics. Addition of bio enzyme on five concrete mixture that will be compared with normal concrete in order to know the optimum level bio-enzyme in concrete to increase the strength of the concrete. Concrete with bio-enzyme 200 ml/m3, 400 ml/m3, 600 ml/m3, 800 ml/m3, 1000 ml/m3 and normal concrete. Refer to the crushing test result, its tends to the mathematical model using 4th degree polynomial regression (least quartic, as represent on the attached data series, which is for the design mix fc′ = 25 MPa generate optimum value for 33,98 MPa, on the bio-additive dosage of 509 ml bio enzymes.

  5. Episodic, generalized, and semantic memory tests: switching and strength effects.

    Science.gov (United States)

    Humphreys, Michael S; Murray, Krista L

    2011-09-01

    We continue the process of investigating the probabilistic paired associate paradigm in an effort to understand the memory access control processes involved and to determine whether the memory structure produced is in transition between episodic and semantic memory. In this paradigm two targets are probabilistically paired with a cue across a large number of short lists. Participants can recall the target paired with the cue in the most recent list (list specific test), produce the first of the two targets that have been paired with that cue to come to mind (generalised test), and produce a free association response (semantic test). Switching between a generalised test and a list specific test did not produce a switching cost indicating a general similarity in the control processes involved. In addition, there was evidence for a dissociation between two different strength manipulations (amount of study time and number of cue-target pairings) such that number of pairings influenced the list specific, generalised and the semantic test but amount of study time only influenced the list specific and generalised test. © 2011 Canadian Psychological Association

  6. Shear bond strength of a new one-bottle dentin adhesive.

    Science.gov (United States)

    Swift, E J; Bayne, S C

    1997-08-01

    To test the shear bond strength of a new adhesive, 3M Single Bond, to dentin surfaces containing different degrees of moisture. Two commercially available one-bottle adhesives (Prime & Bond, One-Step) and a conventional three-step system (Scotchbond Multi-Purpose Plus) were included for comparison. 120 bovine teeth were embedded in acrylic and the labial surfaces were polished to 600 grit to create standardized dentin surfaces for testing. Resin composite was bonded to dentin using a gelatin capsule technique. Four adhesive systems were evaluated with three different degrees of surface moisture (moist, wet, and overwet). Shear bond strengths of adhesives to dentin were determined using a universal testing machine and analyzed by ANOVA and Tukey's post hoc tests. Single Bond had mean shear bond strengths of 19.2, 23.2 and 20.3 MPa to moist, wet, and overwet dentin, respectively. Bond strengths of the three-component system Scotchbond Multi-Purpose Plus ranged from 23.1 to 25.3 MPa, but were not significantly higher than the values for Single Bond. Prime & Bond had bond strengths similar to those of Single Bond, but One-Step had significantly lower bond strengths (P < 0.05) in the wet and overwet conditions.

  7. Effect of technetium Tc 99m pertechnetate on bacterial survival in solution

    International Nuclear Information System (INIS)

    Stathis, V.J.; Miller, C.M.; Doerr, G.F.; Coffey, J.L.; Hladik, W.B.

    1983-01-01

    Survival of Staphylococcus epidermidis (10(2) organisms/ml) in solutions containing various levels of radioactivity was assessed. Six test preparations contained nonbacteriostatic 0.9% sodium chloride solution; four of these contained technetium Tc 99m pertechnetate (99mTcO-4) in various quantities (80, 250, 500, and 750 mCi). A fifth contained technetium that had decayed to an essentially nonradioactive form, and a sixth contained 0.9% sodium chloride solution only. Each of the six 20-ml solutions was inoculated with 2 ml of single-strength trypticase soy broth (TSB) containing 10(3) organisms/ml. At various times up to 12 hours after inoculation, 1-ml aliquots of each test solution were withdrawn and passed through 0.22-micron filters, thereby preventing further irradiation of the filtered organisms. The filters were incubated in single-strength TSB at 37 degrees C, and samples were examined for turbidity at 24, 48, and 72 hours. After 24 hours, 25 of the 36 sample tubes showed turbidity; after 48 hours, the turbid samples totaled 28. Bacteria in the two nonradioactive solutions remained viable throughout the 12-hour sampling period. Accumulated doses of radiation obtained in the 250-, 500-, and 750-mCi samples inhibited bacterial growth. To be a valid quality-control measure, sterility monitoring of prepared radiopharmaceutical dosage forms may need to be performed concurrently with their preparation

  8. Plastic deformation behavior and bonding strength of an EBW joint between 9Cr-ODS and JLF-1 estimated by symmetric four-point bend tests combined with FEM analysis

    International Nuclear Information System (INIS)

    Fu, Haiying; Nagasaka, Takuya; Muroga, Takeo; Guan, Wenhai; Nogami, Shuhei; Serizawa, Hisashi; Geng, Shaofei; Yabuuchi, Kiyohiro; Kimura, Akihiko

    2016-01-01

    The joint between 9Cr-ODS and JLF-1 made by electron beam welding (EBW) fractured at the JLF-1 base metal (BM) during uniaxial tensile tests. Thus, the bonding strength of the joint was not determined and was estimated as more than the ultimate tensile strength of the BM in this case. Symmetric four-point bend tests which concentrate the stress inside the inner span including the weld metal (WM) were carried out at room temperature (RT) and 550 °C to investigate how the bonding strength is more than the ultimate tensile strength of the BM. The normal stress at the center of the weld bead can be calculated with elastic theory up to only 0.25% in strain, though the joint showed more than 10% in strain due to plastic deformation. Thus, finite element method (FEM) was utilized to simulate the plastic deformation behavior of the joint during bend tests. According to the fitting of the FEM output, such as load and displacement of the upper jig contacting the specimens, to the experimental results, the bonding strength of the joint at RT and 550 °C were estimated as 854 MPa and 505 MPa, respectively.

  9. Plastic deformation behavior and bonding strength of an EBW joint between 9Cr-ODS and JLF-1 estimated by symmetric four-point bend tests combined with FEM analysis

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Haiying [SOKENDAI (The Graduate University for Advanced Studies), 322-6 Oroshi-cho, Toki 509-5292 (Japan); Nagasaka, Takuya; Muroga, Takeo [SOKENDAI (The Graduate University for Advanced Studies), 322-6 Oroshi-cho, Toki 509-5292 (Japan); National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan); Guan, Wenhai; Nogami, Shuhei [Tohoku University, 6-6-01-2 Aramaki-aza-Aoba, Aoba-ku, Sendai 980-8578 (Japan); Serizawa, Hisashi [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki 567-0047 (Japan); Geng, Shaofei [SOKENDAI (The Graduate University for Advanced Studies), 322-6 Oroshi-cho, Toki 509-5292 (Japan); Yabuuchi, Kiyohiro; Kimura, Akihiko [Institute of Advanced Energy, Kyoto University, Uji 611-0011 (Japan)

    2016-01-15

    The joint between 9Cr-ODS and JLF-1 made by electron beam welding (EBW) fractured at the JLF-1 base metal (BM) during uniaxial tensile tests. Thus, the bonding strength of the joint was not determined and was estimated as more than the ultimate tensile strength of the BM in this case. Symmetric four-point bend tests which concentrate the stress inside the inner span including the weld metal (WM) were carried out at room temperature (RT) and 550 °C to investigate how the bonding strength is more than the ultimate tensile strength of the BM. The normal stress at the center of the weld bead can be calculated with elastic theory up to only 0.25% in strain, though the joint showed more than 10% in strain due to plastic deformation. Thus, finite element method (FEM) was utilized to simulate the plastic deformation behavior of the joint during bend tests. According to the fitting of the FEM output, such as load and displacement of the upper jig contacting the specimens, to the experimental results, the bonding strength of the joint at RT and 550 °C were estimated as 854 MPa and 505 MPa, respectively.

  10. Personality and Behavior in Social Dilemmas: Testing the Situational Strength Hypothesis and the Role of Hypothetical Versus Real Incentives.

    Science.gov (United States)

    Lozano, José H

    2016-02-01

    Previous research aimed at testing the situational strength hypothesis suffers from serious limitations regarding the conceptualization of strength. In order to overcome these limitations, the present study attempts to test the situational strength hypothesis based on the operationalization of strength as reinforcement contingencies. One dispositional factor of proven effect on cooperative behavior, social value orientation (SVO), was used as a predictor of behavior in four social dilemmas with varying degree of situational strength. The moderating role of incentive condition (hypothetical vs. real) on the relationship between SVO and behavior was also tested. One hundred undergraduates were presented with the four social dilemmas and the Social Value Orientation Scale. One-half of the sample played the social dilemmas using real incentives, whereas the other half used hypothetical incentives. Results supported the situational strength hypothesis in that no behavioral variability and no effect of SVO on behavior were found in the strongest situation. However, situational strength did not moderate the effect of SVO on behavior in situations where behavior showed variability. No moderating effect was found for incentive condition either. The implications of these results for personality theory and assessment are discussed. © 2014 Wiley Periodicals, Inc.

  11. Crystallization of high-strength nano-scale leucite glass-ceramics.

    Science.gov (United States)

    Theocharopoulos, A; Chen, X; Wilson, R M; Hill, R; Cattell, M J

    2013-11-01

    Fine-grained, high strength, translucent leucite dental glass-ceramics are synthesized via controlled crystallization of finely milled glass powders. The objectives of this study were to utilize high speed planetary milling of an aluminosilicate glass for controlled surface crystallization of nano-scale leucite glass-ceramics and to test the biaxial flexural strength. An aluminosilicate glass was synthesized, attritor or planetary milled and heat-treated. Glasses and glass-ceramics were characterized using particle size analysis, X-ray diffraction and scanning electron microscopy. Experimental (fine and nanoscale) and commercial (Ceramco-3, IPS Empress Esthetic) leucite glass-ceramics were tested using the biaxial flexural strength (BFS) test. Gaussian and Weibull statistics were applied. Experimental planetary milled glass-ceramics showed an increased leucite crystal number and nano-scale median crystal sizes (0.048-0.055 μm(2)) as a result of glass particle size reduction and heat treatments. Experimental materials had significantly (p0.05) strength difference. All other groups' mean BFS and characteristic strengths were found to be significantly different (pglass-ceramics with high flexural strength. These materials may help to reduce problems associated with brittle fracture of all-ceramic restorations and give reduced enamel wear. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Back muscle strength, lifting, and stooped working postures.

    Science.gov (United States)

    Poulsen, E; Jørgensen, K

    1971-09-01

    When lifting loads and working in a forward stooped position, the muscles of the back rather than the ligaments and bony structures of the spine should overcome the gravitational forces. Formulae, based on measurements of back muscle strength, for prediction of maximal loads to be lifted, and for the ability to sustain work in a stooped position, have been worked out and tested in practical situations. From tests with 50 male and female subjects the simplest prediction formulae for maximum loads were: max. load = 1.10 x isometric back muscle strength for men; and max. load = 0.95 x isometric back muscle strength - 8 kg for women. Some standard values for maximum lifts and permissible single and repeated lifts have been calculated for men and women separately and are given in Table 1. From tests with 65 rehabilitees it was found that the maximum isometric strength of the back muscles measured at shoulder height should exceed 2/3 of the body weight, if fatigue and/or pain in the back muscles is to be avoided during work in a standing stooped position.

  13. Flexural strength and modulus of elasticity of different types of resin-based composites.

    Science.gov (United States)

    Rodrigues Junior, Sinval Adalberto; Zanchi, Cesar Henrique; Carvalho, Rodrigo Varella de; Demarco, Flávio Fernando

    2007-01-01

    The aim of the study was to test whether the filler composition of resin composites influences their flexural strength and modulus of elasticity. Flexural strength and modulus of elasticity were obtained through a three-point bending test. Twelve bar shaped specimens of 5 commercially available composites--Supreme (3M/ESPE), a universal nanofilled composite; Esthet-X (Dentsply), Z-250 (3M/ESPE), Charisma (Heraeus Kulzer), universal hybrid composites; and Helio Fill (Vigodent), a microfine composite--were confectioned according to the ISO 4049/2000 specifications. The test was performed after a 7-days storage time using a universal test machine with a crosshead speed of 1 mm/min. The filler weight content was determined by the ashing technique. The data obtained on the mechanical properties were submitted to ANOVA and Tukey test (p elasticity results were observed among the universal hybrid composites. The nanofilled composite presented intermediary results. Within the limitations of this in vitro study, it could be concluded that the filler content significantly interfered in the flexural strength and modulus of elasticity of the composites tested.

  14. Can previous acid etching increase the bond strength of a self-etching primer adhesive to enamel?

    Directory of Open Access Journals (Sweden)

    Ana Paula Morales Cobra Carvalho

    2009-06-01

    Full Text Available Because a greater research effort has been directed to analyzing the adhesive effectiveness of self etch primers to dentin, the aim of this study was to evaluate, by microtensile testing, the bond strength to enamel of a composite resin combined with a conventional adhesive system or with a self-etching primer adhesive, used according to its original prescription or used with previous acid etching. Thirty bovine teeth were divided into 3 groups with 10 teeth each (n= 10. In one of the groups, a self-etching primer (Clearfil SE Bond - Kuraray was applied in accordance with the manufacturer's instructions and, in the other, it was applied after previous acid etching. In the third group, a conventional adhesive system (Scotchbond Multipurpose Plus - 3M-ESPE was applied in accordance with the manufacturer's instructions. The results obtained by analysis of variance revealed significant differences between the adhesive systems (F = 22.31. The self-etching primer (Clearfil SE Bond presented lower enamel bond strength values than the conventional adhesive system (Scotchbond Multipurpose Plus (m = 39.70 ± 7.07 MPa both when used according to the original prescription (m = 27.81 ± 2.64 MPa and with previous acid etching (m = 25.08 ± 4.92 MPa.

  15. Development of high toughness, high strength aluminide-bonded carbide ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Becher, P.F.; Plucknett, K.P.; Tiegs, T.N. [Oak Ridge National Lab., TN (United States)] [and others

    1997-04-01

    Cemented carbides are widely used in applications where resistance to abrasion and wear are important, particularly in combination with high strength and stiffness. In the present case, ductile aluminides have been used as a binder phase to fabricate dense carbide cermets by either sintering of mixed powders or a melt-infiltration sintering process. The choice of an aluminide binder was based on the exceptional high temperature strength and chemical stability exhibited by these alloys. For example, TiC-based composites with a Ni{sub 3}Al binder phase exhibit improved oxidation resistance, Young`s moduli > 375 GPa, high fracture strengths (> 1 GPa) that are retained to {ge} 900{degrees}C, and fracture toughness values of 10 to 15 MPa{radical}m, identical to that measured in commercial cobalt-bonded WC with the same test method. The thermal diffusivity values at 200{degrees}C for these composites are {approximately} 0.070 to 0.075 cm{sup 2}/s while the thermal expansion coefficients rise with Ni3Al content from {approximately} 8 to {approximately}11 x 10{sup {minus}6}/{degrees}C over the range of 8 to 40 vol. % Ni{sub 3}Al. The oxidation and acidic corrosion resistances are quite promising as well. Finally, these materials also exhibit good electrical conductivity allowing them to be sectioned and shaped by electrical discharge machining (EDM) processes.

  16. Crushing strength of HTGR fuel particles

    International Nuclear Information System (INIS)

    Lackey, W.J.; Stinton, D.P.; Davis, L.E.; Beatty, R.L.

    1976-01-01

    The whole-particle crushing strengths of High-Temperature Gas-Cooled Reactor fertile and fissile coated particles were measured and correlated with fabrication procedures. The crushing strength of Biso-coated fertile particles was increased by the following factors: (1) increasing the outer coating thickness by 10 μm increased strengths by 0.3 lb (1.3 N) for annealed particles and by 0.5 lb (2.2 N) for unannealed particles. (2) An 1800 0 C postcoating anneal increased strengths by 1 lb (4.4 N) for particles with thick outer coatings and by 2 lb (8.9 N) for particles having thin coatings. (3) Increasing the inner coating density by 0.1 g/cm 3 increased strength by 0.6 lb (2.7 N). The crushing strength of Triso-coated fissile particles was proportional to the thickness of the SiC coatings, and strength decreased on annealing by about 0.2 lb (0.9 N) when a porous plate was used to distribute the coating gas and by about 1.5 lb (6.7 N) when a conical gas distributor was used. The strengths of fertile and fissile coated particles as well as uncoated kernels appear adequate to allow fuel fabrication without excessive particle damage

  17. Effect of in vitro aging on the flexural strength and probability to fracture of Y-TZP zirconia ceramics for all-ceramic restorations.

    Science.gov (United States)

    Siarampi, Eleni; Kontonasaki, Eleana; Andrikopoulos, Konstantinos S; Kantiranis, Nikolaos; Voyiatzis, George A; Zorba, Triantafillia; Paraskevopoulos, Konstantinos M; Koidis, Petros

    2014-12-01

    Dental zirconia restorations should present long-term clinical survival and be in service within the oral environment for many years. However, low temperature degradation could affect their mechanical properties and survival. The aim of this study was to investigate the effect of in vitro aging on the flexural strength of yttrium-stabilized (Y-TZP) zirconia ceramics for ceramic restorations. One hundred twenty bar-shaped specimens were prepared from two ceramics (ZENO Zr (WI) and IPS e.max(®) ZirCAD (IV)), and loaded until fracture according to ISO 6872. The specimens from each ceramic (nx=60) were divided in three groups (control, aged for 5h, aged for 10h). One-way ANOVA was used to assess statistically significant differences among flexural strength values (Pceramics, however statistically significant was for the WI group (Pceramics presented a t→m phase transformation, with the m-phase increasing from 4 to 5% at 5h to around 15% after 10h. The significant reduction of the flexural strength after 10h of in vitro aging, suggests high fracture probability for one of the zirconia ceramics tested. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  18. Predicting hand function in older adults: evaluations of grip strength, arm curl strength, and manual dexterity.

    Science.gov (United States)

    Liu, Chiung-Ju; Marie, Deana; Fredrick, Aaron; Bertram, Jessica; Utley, Kristen; Fess, Elaine Ewing

    2017-08-01

    Hand function is critical for independence in activities of daily living for older adults. The purpose of this study was to examine how grip strength, arm curl strength, and manual dexterous coordination contributed to time-based versus self-report assessment of hand function in community-dwelling older adults. Adults aged ≥60 years without low vision or neurological disorders were recruited. Purdue Pegboard Test, Jamar hand dynamometer, 30-second arm curl test, Jebsen-Taylor Hand Function Test, and the Late-Life Function and Disability Instrument were administered to assess manual dexterous coordination, grip strength, arm curl strength, time-based hand function, and self-report of hand function, respectively. Eighty-four adults (mean age = 72 years) completed the study. Hierarchical multiple regressions show that older adults with better arm curl strength (β = -.25, p function test. In comparison, older adults with better grip strength (β = .40, p function. The relationship between grip strength and hand function may be test-specific. Grip strength becomes a significant factor when the test requires grip strength to successfully complete the test tasks. Arm curl strength independently contributed to hand function in both time-based and self-report assessments, indicating that strength of extrinsic muscles of the hand are essential for hand function.

  19. Tensile strength/yield strength (TS/YS) ratios of high-strength steel (HSS) reinforcing bars

    Science.gov (United States)

    Tavio, Anggraini, Retno; Raka, I. Gede Putu; Agustiar

    2018-05-01

    The building codes such as American Concrete Institute (ACI) 318M-14 and Standard National Indonesia (SNI) 2847:2013 require that the ratio of tensile strength (TS) and yield strength (YS) should not less than 1.25. The requirement is based on the assumption that a capability of a structural member to develop inelastic rotation capacity is a function of the length of the yield region. This paper reports an investigation on various steel grades, namely Grades 420, 550, 650, and 700 MPa, to examine the impact of different TS/YS ratios if it is less or greater than the required value. Grades 550, 650, and 700 MPa were purposely selected with the intention to examine if these higher grades are still promising to be implemented in special structural systems since they are prohibited by the building codes for longitudinal reinforcement, whereas Grade 420 MPa bars are the maximum limit of yield strength of reinforcing bars that is allowable for longitudinal reinforcement of special structural systems. Tensile tests of these steel samples were conducted under displacement controlled mode to capture the complete stress-strain curves and particularly the post-yield response of the steel bars. From the study, it can be concluded that Grade 420 performed higher TS/YS ratios and they were able to reach up to more than 1.25. However, the High Strength Still (HSS) bars (Grades 550, 600, and 700 MPa) resulted in lower TS/YS ratios (less than 1.25) compared with those of Grade 420 MPa.

  20. SHOULDER EXTERNAL ROTATOR STRENGTH IN RESPONSE TO VARIOUS SITTING POSTURES: A CONTROLLED LABORATORY STUDY.

    Science.gov (United States)

    Pheasant, Steven; Haydt, Richard; Gottstein, Thomas; Grasso, Anthony; Lombard, Nicholas; Stone, Brandon

    2018-02-01

    The forward head rounded shoulder (FHRS) sitting posture has been associated with decreased shoulder complex muscle strength and function. Upon clinical observation, the adverse effects of the FHRS sitting posture on shoulder complex isometric muscle strength is also present when testing controls for scapular position. The purpose of the study was to assess the effect of various sitting postures on shoulder external rotator muscle isometric strength when the strength testing controls for scapular position. A cohort study, with subjects serving as their own controls. One hundred subjects ages 20-26 participated in the study. Each subject was placed in a neutral cervical sitting (NCS) posture which was maintained for five minutes after which the strength of the dominant shoulder external rotators was immediately tested with the glenohumeral joint in the neutral position using a Micro-FET3 Hand Held Muscle Testing Dynamometer (HHMTD). Each subject was returned to the NCS posture for subsequent external rotator strength testing after five minutes in a FHRS sitting posture, five additional minutes in the NCS posture and five minutes in a retracted cervical sitting (RCS) posture resulting in each subjects' external rotator strength being tested on four occasions. Subjects were randomized for order between the FHRS and RCS postures. Mean strength values for each condition were normalized to the mean strength value for the 1 st NCS condition for each subject. A statistically significant decline in shoulder external rotator strength following the FHRS sitting posture occurred compared to the appropriate postural conditions (pexternal rotator strength following five minutes in the FHRS sitting posture. The average percentage of strength decline in those with greater than a 10% reduction in external rotator strength was 19%. Sixty-four percent of the subjects experienced less than a 10% decline in shoulder external rotator strength in response to the FHRS sitting posture

  1. [Case-control study on the effect of core strength training on the function of anterior cruciate ligament reconstruction].

    Science.gov (United States)

    Wu, Bin; Zheng, Song; Cai, Zhen-Hai; Wang, Yue-Li; Zeng, Ming

    2017-08-25

    To observe the effect of core strength training on knee joint function and postural stability after anterior cruciate ligament reconstruction (ACLR). A total of 80 ACLR patients were randomly allocated into conventional rehabilitation training group and core strength training group from May 2013 to May 2015 with 40 patients in each group. The patients in conventional rehabilitation training group underwent conventional ACLR rehabilitation training, in which 28 males and 12 females. The mean age was(30.5±5.2) years old(ranged, 22 to 42 years old). The mean BMI was(23.8±2.4) kg/m²(ranged, 18.2 to 25.9 kg/m²). Thirty patients had injuries on the dominant side and 10 patients had injuries on the non-dominant side. The core strength training group received conventional ACLR rehabilitation training and core strength training, in which 31 males and 9 females. The mean age was(31.1±4.8) years old(ranged, 21 to 45 years old). The mean BMI was(24.1±2.7) kg/m²(ranged, 18.5 to 26.1 kg/m²) . Twenty-seven patients had injuries on the dominant side and 13 patients had injuries on the non-dominant side. The Lysholm score, tibial anterior transition measured by KT-1000 before and after treatment, and the Star Excursion Balance Test results after treatment were compared between the two groups. Six months after rehabilitation training, the tibial anterior transition of the conventional rehabilitation training group and the core strength training group were(3.4±1.0) mm and(3.3±1.2) mm respectively, which were less than(12.1±1.8) mm and(12.5±2.0) mm before treatment. But there was no significant difference in anterior tibial translation between two groups( P >0.05). The Lysholm score of the conventional rehabilitation training group and the core strength training group were 91.8±4.3 and 92.1±3.9 individually, which were higher than 69.2±5.8 and 70.2±5.1 before treatment. But there was no significant difference in Lysholm score between two groups( P >0.05). Six months

  2. COMPOSITE RESIN BOND STRENGTH TO ETCHED DENTINWITH ONE SELF PRIMING ADHESIVE

    Directory of Open Access Journals (Sweden)

    P SAMIMI

    2002-09-01

    Full Text Available Introduction. The purpose of this study was to compare shear bond strength of composite resins to etched dentin in both dry and wet dentin surface with active and inactive application of a single-bottle adhesive resin (Single Bond, 3M Dental products. Methods. Fourthy four intact human extracted molars and premolars teeth were selected. The facial surfaces of the teeth were grounded with diamond bur to expose dentin. Then specimens were divided into four groups of 11 numbers (9 Molars and 2 Premolars. All the samples were etched with Phosphoric Acid Gel 35% and then rinsed for 10 seconds. The following stages were carried out for each group: Group I (Active-Dry: After rinsing, air drying of dentin surface for 15 seconds, active priming of adhesive resin for 15 seconds, air drying for 5 seconds, the adhesive resin layer was light cured for 10 seconds. Group III (Inactive-Dry:After rinsing, air drying of dentin surface for 15 seconds, adhesive resin was applied and air dryied for 5 seconds, the adhesive layer was light cured for 10 seconds. Group III (Active-Wet:After rinsing, removal of excess water of dentin surface with a cotton roll, active priming of adhesive resin for 15 seconds and air drying for 5 seconds, the adhesive layer was light cured for 10 seconds. Group IV (Inactive-Wet:After rinsing, removal of excess water of dentin surface with a cotton roll, the adhesive resin was applied and air dryied for 5 seconds and then cured for 10 seconds. After adhesive resin application, composite resin (Z250, 3M Dental products was applied on prepared surface with cylindrical molds (with internal diameter of 2.8mm, & height of 5mm and light-cured for 100 seconds (5x20s. The samples were then thermocycled. They were located in 6±3c water .temperature for 10 seconds and then 15 seconds in inviromental temperature, 10s in 55±3c water temperature and then were located at room temperature for 15s. This test was repeated for 100s. All of the specimens

  3. Effect of root canal rinsing protocol on dentin bond strength of two resin cements using three different method of test.

    Science.gov (United States)

    Khoroushi, Maryam; Sheikhi, Mohammadreza; Khalilian-Gourtani, Amirhossein; Soleimani, Bahram

    2016-07-01

    Different studies have used different tests to evaluate bond strength of resin cements to root dentin. In this in vitrostudy, three different tests were used to evaluate the bond strength of two resin cements to root dentin using two root dentin irrigation protocols. Ninety-six intact single-rooted teeth were selected for this study. Forty-eight teeth, with a root length of 15mm, were randomly divided into two groups and irrigated with normal saline or 2.5% sodium hypochlorite solutions during root canal preparation, respectively. For each 12 specimens from each group, fiber post #1 was bonded using an etch-and-rinse (Duo-Link) and a self-adhesive (BisCem) resin cement, respectively. After incubation, two specimens were prepared for the push-out test from the middle thirds of the roots. In another 24 teeth, after two 1.5-mm sections were prepared from the middle thirds of the prepared roots, sections of the post were bonded in two subgroups with each of the cements mentioned above and the samples were prepared for the pull-out test. For shear test, the crowns of 48 teeth were cut away, the dentin surfaces were prepared, the two irrigation solutions were used, and the resin cements were bonded. Data collected from the three tests were evaluated by ANOVA, post-hoc Tukey and Weibull tests (α=0.05). There were significant differences in the mean bond strength values between the three bond strength tests (Pstrength in all tests (P>0.05). Under the limitations of the present study, the method of the test used had an effect on the recorded bond strength between the resin cement and root dentin. Cement type and irrigation protocol resulted in similar variations with all the tests. Push-out and shear tests exhibited more coherent results. Bond strength, endodontically treated tooth, fiber post, resin cement, sodium hypochlorite.

  4. Green and early age compressive strength of extruded cement mortar monitored with compression tests and ultrasonic techniques

    International Nuclear Information System (INIS)

    Voigt, Thomas; Malonn, Tim; Shah, Surendra P.

    2006-01-01

    Knowledge about the early age compressive strength development of cementitious materials is an important factor for the progress and safety of many construction projects. This paper uses cylindrical mortar specimens produced with a ram extruder to investigate the transition of the mortar from plastic and deformable to hardened state. In addition, wave transmission and reflection measurements with P- and S-waves were conducted to obtain further information about the microstructural changes during the setting and hardening process. The experiments have shown that uniaxial compression tests conducted on extruded mortar cylinders are a useful tool to evaluate the green strength as well as the initiation and further development of the compressive strength of the tested material. The propagation of P-waves was found to be indicative of the internal structure of the tested mortars as influenced, for example, by the addition of fine clay particles. S-waves used in transmission and reflection mode proved to be sensitive to the inter-particle bonding caused by the cement hydration and expressed by an increase in compressive strength

  5. Development of high strength steel sheets for crashworthiness; Shototsu anzen`yo kokyodo usu koban no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Fukui, K; Yamamoto, M; Mizui, N; Hirose, Y; Kojima, K [Sumitomo Metal Industries, Ltd. Osaka (Japan)

    1997-10-01

    For frontal or rear members of automotive body, the most suitable high strength steel was investigated. Dynamic tensile test at strain-rate of 2000/s and crash test of hat-shape column at 4m/s were conducted for steel sheets with tensile strength ranging from 290 to 980 MPa. Dynamic tensile strength increases with increasing static one but the ratio of dynamic tensile strength to static one decreases. Tensile strength remarkably affects crash energy absorption of column and TRIP steel is superior to other steels with same tensile strength. 7 refs., 16 figs., 1 tab.

  6. Shear Strength of Stabilized Kaolin Soil Using Liquid Polymer

    Science.gov (United States)

    Azhar, A. T. S.; Fazlina, M. I. S.; Nizam, Z. M.; Fairus, Y. M.; Hakimi, M. N. A.; Riduan, Y.; Faizal, P.

    2017-08-01

    The purpose of this research is to investigate the suitability of polymer in soil stabilization by examining its strength to withstand compressive strength. Throughout this research study, manufactured polymer was used as a chemical liquid soil stabilizer. The liquid polymer was diluted using a proposed dilution factor of 1 : 3 (1 part polymer: 3 parts distilled water) to preserve the workability of the polymer in kaolin mixture. A mold with a diameter of 50 mm and a height of 100 mm was prepared. Kaolin soil was mixed with different percentages of polymer from 10%, 15%, 20%, 25%, 30% and 35% of the mass of the kaolin clay sample. Kaolin mixtures were tested after a curing period of 3 days, 7 days, 14 days and 28 days respectively. The physical properties were determined by conducting a moisture content test and Atterberg limit test which comprise of liquid limit, plastic limit and shrinkage limit. Meanwhile, the mechanical properties of the soil shear strength were identified through an unconfined compressive strength (UCS) test. Stabilized kaolin soil showed the highest compressive strength value when it was mixed with 35% of polymer compared to other percentages that marked an increment in strength which are 45.72% (3 days), 67.57% (7 days), 81.73% (14 days) and 77.84% (28 days). Hence, the most effective percentage of liquid polymer which should be used to increase the strength of kaolin soil is 35%.

  7. The Use Level of Chrome Tannage For Rabbit Fur Leather Observed on Tearing Strength, Stitch Tearing Strength, Water Absorption and Organoleptic

    Directory of Open Access Journals (Sweden)

    Mustakim Mustakim

    2012-02-01

    Full Text Available The purpose of this study was to find out the appropiate of chrome tannage level for rabbit fur leather quality. The result were expected to contribute information for many people who relate with tanning technology, especialy about the use level of chrome tannage for fur leather quality and could as patern to hold further research.The material that used were 12 pieces of three months of rabbit skin. The method is Completely Randomized Design, consist of three treatments of chrome tannage (Chromosal B, they were : B1 (Chromosal B 6%, B2 (Chromosal B 8%, and B3 (Chromosal B 10%. Each of treatment hold on four replications. The variables which measured are tearing strength, stitch teraing strength, water absorption and organoleptic consist of “kekuatan bulu”’ “kerataan bulu” and “kelemasan kulit” in fur leather. Data was analysed by analysis variance followed by Duncan’s Multiple Range Test. The result of this research show that the use level of chromosal B give very significant influence among tearing strength, stitch tearing strength and water absorption. It gave significant influence among the organoleptic test. Based on the result, can be concluded that 10 percent of chrome tannage (chromosal B, produce the best result on tearing strength, stitch tearing strength, water absorption and organoleptic for “kekuatan bulu” and “kerataan bulu”. The incrase of chrome tannage offer will decrease the “kelemasan kulit” in fur leather and the best “kelemasan kulit” produced by the lowest chrome tannage offer, that was 6 percent of Chromosal B. The best quality of rabbit fur leather produced by 10 percent of chrome tannage offer.   Keywords: chrome, tannage, fur leather

  8. Syngeneic B16F10 Melanoma Causes Cachexia and Impaired Skeletal Muscle Strength and Locomotor Activity in Mice

    Directory of Open Access Journals (Sweden)

    Fabrício A. Voltarelli

    2017-09-01

    Full Text Available Muscle wasting has been emerging as one of the principal components of cancer cachexia, leading to progressive impairment of work capacity. Despite early stages melanomas rarely promotes weight loss, the appearance of metastatic and/or solid tumor melanoma can leads to cachexia development. Here, we investigated the B16F10 tumor-induced cachexia and its contribution to muscle strength and locomotor-like activity impairment. C57BL/6 mice were subcutaneously injected with 5 × 104 B16F10 melanoma cells or PBS as a Sham negative control. Tumor growth was monitored during a period of 28 days. Compared to Sham mice, tumor group depicts a loss of skeletal muscle, as well as significantly reduced muscle grip strength and epididymal fat mass. This data are in agreement with mild to severe catabolic host response promoted by elevated serum tumor necrosis factor-alpha (TNF-α, interleukin-6 (IL-6 and lactate dehydrogenase (LDH activity. Tumor implantation has also compromised general locomotor activity and decreased exploratory behavior. Likewise, muscle loss, and elevated inflammatory interleukin were associated to muscle strength loss and locomotor activity impairment. In conclusion, our data demonstrated that subcutaneous B16F10 melanoma tumor-driven catabolic state in response to a pro-inflammatory environment that is associated with impaired skeletal muscle strength and decreased locomotor activity in tumor-bearing mice.

  9. Results of LIA-10M accelerator investigations

    CERN Document Server

    Gordeev, V S; Filippov, V O

    2001-01-01

    There are presented basic results of experiments on the LIA-10M accelerator since its putting into operation (1994) till today. There were investigated various modes of accelerator operation and its output characteristics depending on the parameters of injected electron beam,number of connected accelerator modules,time program of inductors switch-in etc. There was obtained a large scope of experimental data that are of interest for LIA-10M accelerator practical use and for the development of new facilities of this type. The investigations that have been performed recently make it possible to considerably (half as much again) increase the output dose parameters of the accelerator as compared to the level achieved before:maximal dose(Si) and dose rate on the output flange constitute 400 Gy and 2.5 centre dot 10 Gy/s, while at a 1 meter distance from the target they are equal to 7.5 Gy and 5 centre dot 10 sup 8 Gy/s, respectively.

  10. Strength and leak testing of plasma activated bonded interfaces

    DEFF Research Database (Denmark)

    Visser, M.M.; Weichel, Steen; Reus, Roger De

    2002-01-01

    on detection of changes in membrane deflections. The detection limit for leak was 8E-13 mbar l/s. For comparison, strength and leak tests were also performed with regular fusion bonded wafers annealed at 1100 degreesC. The PAB was found to withstand post-processing steps such as RCA cleaning, 24 h in de......-ionised water (DIW), 24 h in 2.5% HF, 24 h in acetone and 60 s in a resist developer. By analysing the thin silicon oxide present on the surfaces to be bonded with optical methods, the influence of pre-cleaning and activation process parameters was investigated....

  11. Evaluation of in-place concrete strength by core testing.

    Science.gov (United States)

    2016-11-01

    The overall objective of the work contained in this report is to develop an ALDOT procedure to evaluate core strength results obtained under various conditions. Since there are many factors that influence the apparent strength of cores, strength corr...

  12. Effect of chlorhexidine application on the bond strength of resin core to axial dentin in endodontic cavity

    Directory of Open Access Journals (Sweden)

    Yun-Hee Kim

    2012-11-01

    Full Text Available Objectives This study evaluated the influence of chlorhexidine (CHX on the microtensile bonds strength (µTBS of resin core with two adhesive systems to dentin in endodontic cavities. Materials and Methods Flat dentinal surfaces in 40 molar endodontic cavities were treated with self-etch adhesive system, Contax (DMG and total-etch adhesive system, Adper Single Bond 2 (3M ESPE after the following surface treatments: (1 Priming only (Contax, (2 CHX for 15 sec + rinsing + priming (Contax, (3 Etching with priming (Adper Single Bond 2, (4 Etching + CHX for 15 sec + rinsing + priming (Adper Single Bond 2. Resin composite build-ups were made with LuxaCore (DMG using a bulk method and polymerized for 40 sec. For each condition, half of specimens were submitted to µTBS after 24 hr storage and half of them were submitted to thermocycling of 10,000 cycles between 5℃ and 55℃ before testing. The data were analyzed using ANOVA and independent t-test at a significance level of 95%. Results CHX pre-treatment did not affect the bond strength of specimens tested at the immediate testing period, regardless of dentin surface treatments. However, after 10,000 thermocycling, all groups showed reduced bond strength. The amount of reduction was greater in groups without CHX treatments than groups with CHX treatment. These characteristics were the same in both self-etch adhesive system and total-etch adhesive system. Conclusions 2% CHX application for 15 sec proved to alleviate the decrease of bond strength of dentin bonding systems. No significant difference was shown in µTBS between total-etching system and self-etching system.

  13. The strength evaluation and σ-phase aging behavior of cast stainless steel

    International Nuclear Information System (INIS)

    Kwon, Jae Do; Park, Joong Cheul; Lee, Woo Ho; Jang, Sun Sik

    1999-01-01

    σ-phase of cast stainless steel(CF8M) was artificially precipitated by means of thermal aging at 700 deg C with various holding time (0.33, 5, 15, 50 and 150 hrs) to evaluate the behavior of thermal aging status of strength change. The structure observation, hardness test, tensile test, impact test and fatigue crack growth rates test for as-received and degraded material were also performed to evaluate static strength, toughness and fatigue crack growth behavior corresponding to the aging condition of CF8M. The results showed that the area fraction of σ-phase and hardness value increased with thermal aging time. But, for the impact values, upper shelf energy decreased and fatigue crack growth rates increased with σ-phase aging progressed than that of virgin material

  14. Ion Exchange Distribution Coefficient Tests and Computer Modeling at High Ionic Strength Supporting Technetium Removal Resin Maturation

    Energy Technology Data Exchange (ETDEWEB)

    Nash, Charles A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Hamm, L. Larry [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Smith, Frank G. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); McCabe, Daniel J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2014-12-19

    stream without dilution and to minimize the volume of the final wasteform. This work examined the impact of high ionic strength, high density, and high viscosity if higher concentration LAW feed solution is used. Perrhenate (ReO4-) has been shown to be a good nonradioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin, and the performance bias is well established. Equilibrium contact testing with 7.8 M [Na+] average simulant concentrations indicated that the SuperLig® 639 resin average perrhenate distribution coefficient was 368 mL/g at a 100:1 phase ratio. Although this indicates good performance at high ionic strength, an equilibrium test cannot examine the impact of liquid viscosity, which impacts the diffusivity of ions and therefore the loading kinetics. To get an understanding of the effect of diffusivity, modeling was performed, which will be followed up with column tests in the future.

  15. Effect of calcium hydroxide and double and triple antibiotic pastes on the bond strength of epoxy resin-based sealer to root canal dentin.

    Science.gov (United States)

    Akcay, Merve; Arslan, Hakan; Topcuoglu, Hüseyin Sinan; Tuncay, Oznur

    2014-10-01

    The aim of this study was to evaluate the effects of calcium hydroxide (CH) and triple (TAP) and double (DAP) antibiotic pastes on the bond strength of an epoxy resin-based sealer (AH Plus Jet; Dentsply DeTrey, Konstanz, Germany) to the root canal dentin. Sixty-four single-rooted human mandibular premolars were decoronated and prepared using the rotary system to size 40. The specimens were randomly divided into a control group (without intracanal dressing) and 3 experimental groups that received an intracanal dressing with either CH, DAP, or TAP (n = 16). The intracanal dressing was removed by rinsing with 10 mL 17% EDTA followed by 10 mL 2.5% sodium hypochlorite. The root canals were then obturated with gutta-percha and AH Plus Jet sealer. A push-out test was used to measure the bond strength between the root canal dentin and the sealer. The data were analyzed using 2-way analysis of variance and Tukey post hoc tests to detect the effect of the independent variables (intracanal medicaments and root canal thirds) and their interactions on the push-out bond strength of the root canal filling material to the root dentin (P = .05). The push-out bond strength values were significantly affected by the intracanal medicaments (P .05). In the middle and apical third, the bond strength of the TAP group was higher than those of the CH and DAP groups (P < .05). The DAP and CH did not affect the bond strength of the epoxy resin-based sealer. Additionally, the TAP improved the bond strength of the epoxy resin-based sealer in the middle and apical thirds. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Inline skating for balance and strength promotion in children during physical education.

    Science.gov (United States)

    Muehlbauer, Thomas; Kuehnen, Matthias; Granacher, Urs

    2013-12-01

    Deficiencies in balance and strength are common in children and they may lead to injuries. This study investigated the effects of inline skating exercise on balance and strength performance in healthy children. Twenty 11-12-year-old children (8 girls, 12 boys) were assigned to an intervention (n = 10) or a control (n = 10) group. Participants in the intervention group underwent a 4-week inline skating program (2 times/week, 90 min. each) integrated in their physical education lessons. Balance and strength were measured using the Star Excursion Balance test and the countermovement jump test. As compared to the control group, the intervention group significantly improved balance (17-48%, Cohen's d = 0.00-1.49) and jump height (8%, Cohen's d = 0.48). In children, inline skating is a safe, feasible (90% adherence rate), and effective program that can be integrated in physical education lessons to promote balance and strength.

  17. Clinical assessment of hip strength using a hand-held dynamometer is reliable

    DEFF Research Database (Denmark)

    Thorborg, K; Petersen, J; Magnusson, S P

    2010-01-01

    rotation (ER), internal rotation (IR), flexion (FLEX) and extension (EXT) using a hand-held dynamometer. Nine subjects (five males, four females), physically active for at least 2.5 h a week, were included. Twelve standardized isometric strength tests were performed twice with a 1-week interval in between......Hip strength assessment plays an important role in the clinical examination of the hip and groin region. The primary aim of this study was to examine the absolute test-retest measurement variation concerning standardized strength assessments of hip abduction (ABD), adduction (ADD), external...... by the same examiner. The test order was randomized to avoid systematic bias. Measurement variation between sessions was 3-12%. When the maximum value of four measurements was used, test-retest measurement variation was below 10% in 11 of the 12 individual hip strength tests and below 5% in five of the 12...

  18. Duration Test Report for the Ventera VT10 Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J.; Huskey, A.; Jager, D.; Hur, J.

    2013-06-01

    This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small wind turbines. Five turbines were tested at the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) as a part of round one of this project. Duration testing is one of up to five tests that may be performed on the turbines, including power performance, safety and function, noise, and power quality. Test results will provide manufacturers with reports that can be used to fulfill part of the requirements for small wind turbine certification. The test equipment included a grid-connected Ventera Energy Corporation VT10 wind turbine mounted on an 18.3-m (60-ft) self-supporting lattice tower manufactured by Rohn.

  19. Polypropylene-rubber blends b 3: the effect of test speed on the fracture behaviour

    NARCIS (Netherlands)

    van der Wal, A.; Wal, A.; Gaymans, R.J.

    1999-01-01

    Polypropylene–EPDM blends were prepared on a twin screw extruder with a rubber content 0–40 vol%. On these materials the yield strength and the notched tensile behaviour was studied as function of test speed (10−4–10 m/s). With an infrared temperature camera the heat development in the notched

  20. Vitamin C and E supplementation alters protein signalling after a strength training session, but not muscle growth during 10 weeks of training.

    Science.gov (United States)

    Paulsen, G; Hamarsland, H; Cumming, K T; Johansen, R E; Hulmi, J J; Børsheim, E; Wiig, H; Garthe, I; Raastad, T

    2014-12-15

    This study investigated the effects of vitamin C and E supplementation on acute responses and adaptations to strength training. Thirty-two recreationally strength-trained men and women were randomly allocated to receive a vitamin C and E supplement (1000 mg day(-1) and 235 mg day(-1), respectively), or a placebo, for 10 weeks. During this period the participants' training involved heavy-load resistance exercise four times per week. Muscle biopsies from m. vastus lateralis were collected, and 1 repetition maximum (1RM) and maximal isometric voluntary contraction force, body composition (dual-energy X-ray absorptiometry), and muscle cross-sectional area (magnetic resonance imaging) were measured before and after the intervention. Furthermore, the cellular responses to a single exercise session were assessed midway in the training period by measurements of muscle protein fractional synthetic rate and phosphorylation of several hypertrophic signalling proteins. Muscle biopsies were obtained from m. vastus lateralis twice before, and 100 and 150 min after, the exercise session (4 × 8RM, leg press and knee-extension). The supplementation did not affect the increase in muscle mass or the acute change in protein synthesis, but it hampered certain strength increases (biceps curl). Moreover, increased phosphorylation of p38 mitogen-activated protein kinase, Extracellular signal-regulated protein kinases 1 and 2 and p70S6 kinase after the exercise session was blunted by vitamin C and E supplementation. The total ubiquitination levels after the exercise session, however, were lower with vitamin C and E than placebo. We concluded that vitamin C and E supplementation interfered with the acute cellular response to heavy-load resistance exercise and demonstrated tentative long-term negative effects on adaptation to strength training. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  1. X-Ray Microtomography (μCT as a Useful Tool for Visualization and Interpretation of Shear Strength Test Results

    Directory of Open Access Journals (Sweden)

    Stefaniuk Damian

    2015-02-01

    Full Text Available The paper demonstrates the applicability of X-ray microtomography (ìCT to analysis of the results of shear strength examinations of clayey soils. The method of X-ray three-dimensional imaging offers new possibilities in soil testing. The work focuses on a non-destructive method of evaluation of specimen quality used in shear tests and mechanical behavior of soil. The paper presents the results of examination of 4 selected clayey soils. Specimens prepared for the triaxial test have been scanned using ìCT before and after the triaxial compression tests. The shear strength parameters of the soils have been estimated. Changes in soil structure caused by compression and shear failure have been presented as visualizations of the samples tested. This allowed for improved interpretation and evaluation of soil strength parameters and recognition of pre-existing fissures and the exact mode of failure. Basic geometrical parameters have been determined for selected cross-sections of specimens after failure. The test results indicate the utility of the method applied in soil testing.

  2. Comparison of bond strengths of ceramic brackets bonded to zirconia surfaces using different zirconia primers and a universal adhesive.

    Science.gov (United States)

    Lee, Ji-Yeon; Ahn, Jaechan; An, Sang In; Park, Jeong-Won

    2018-02-01

    The aim of this study is to compare the shear bond strengths of ceramic brackets bonded to zirconia surfaces using different zirconia primers and universal adhesive. Fifty zirconia blocks (15 × 15 × 10 mm, Zpex, Tosoh Corporation) were polished with 1,000 grit sand paper and air-abraded with 50 µm Al 2 O 3 for 10 seconds (40 psi). They were divided into 5 groups: control (CO), Metal/Zirconia primer (MZ, Ivoclar Vivadent), Z-PRIME Plus (ZP, Bisco), Zirconia Liner (ZL, Sun Medical), and Scotchbond Universal adhesive (SU, 3M ESPE). Transbond XT Primer (used for CO, MZ, ZP, and ZL) and Transbond XT Paste was used for bracket bonding (Gemini clear ceramic brackets, 3M Unitek). After 24 hours at 37°C storage, specimens underwent 2,000 thermocycles, and then, shear bond strengths were measured (1 mm/min). An adhesive remnant index (ARI) score was calculated. The data were analyzed using one-way analysis of variance and the Bonferroni test ( p = 0.05). Surface treatment with primers resulted in increased shear bond strength. The SU group showed the highest shear bond strength followed by the ZP, ZL, MZ, and CO groups, in that order. The median ARI scores were as follows: CO = 0, MZ = 0, ZP = 0, ZL = 0, and SU = 3 ( p < 0.05). Within this experiment, zirconia primer can increase the shear bond strength of bracket bonding. The highest shear bond strength is observed in SU group, even when no primer is used.

  3. High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study.

    Science.gov (United States)

    Gnandt, Ryan J; Smith, Jennifer L; Nguyen-Ta, Kim; McDonald, Lucas; LeClere, Lance E

    2016-02-01

    To determine which suture design, high-tensile strength tape or high-tensile strength suture, performed better at securing human tissue across 4 selected suture techniques commonly used in tendinous repair, by comparing the total load at failure measured during a fixed-rate longitudinal single load to failure using a biomechanical testing machine. Matched sets of tendon specimens with bony attachments were dissected from 15 human cadaveric lower extremities in a manner allowing for direct comparison testing. With the use of selected techniques (simple Mason-Allen in the patellar tendon specimens, whip stitch in the quadriceps tendon specimens, and Krackow stitch in the Achilles tendon specimens), 1 sample of each set was sutured with a 2-mm braided, nonabsorbable, high-tensile strength tape and the other with a No. 2 braided, nonabsorbable, high-tensile strength suture. A total of 120 specimens were tested. Each model was loaded to failure at a fixed longitudinal traction rate of 100 mm/min. The maximum load and failure method were recorded. In the whip stitch and the Krackow-stitch models, the high-tensile strength tape had a significantly greater mean load at failure with a difference of 181 N (P = .001) and 94 N (P = .015) respectively. No significant difference was found in the Mason-Allen and simple stitch models. Pull-through remained the most common method of failure at an overall rate of 56.7% (suture = 55%; tape = 58.3%). In biomechanical testing during a single load to failure, high-tensile strength tape performs more favorably than high-tensile strength suture, with a greater mean load to failure, in both the whip- and Krackow-stitch models. Although suture pull-through remains the most common method of failure, high-tensile strength tape requires a significantly greater load to pull-through in a whip-stitch and Krakow-stitch model. The biomechanical data obtained in the current study indicates that high-tensile strength tape may provide better repair

  4. First TREAT [Transient Reactor Test Facility] transient overpower tests on U-Pu-Zr fuel: M5 and M6

    International Nuclear Information System (INIS)

    Robinson, W.R.; Bauer, T.H.; Wright, A.E.; Rhodes, E.A.; Stanford, G.S.; Klickman, A.E.

    1987-01-01

    Transient Reactor Test Facility (TREAT) tests M5 and M6 were the first transient overpower (TOP) tests of the margin to cladding breach and prefailure elongation of metallic U-Pu-Zr ternary fuel, the reference fuel of the Integral Fast Reactor concept. Similar tests on U-Fs fueled EBR-II driver pins were previously performed and reported [1,2]. Results from these earlier tests indicated a margin to failure of about 4 times nominal power and significant axial elongation prior to failure, a feature that was very pronounced at low burnups. While these two fuel types are similar in many respects, the ternary alloy exhibits a much more complex physical structure and is typically irradiated at much higher temperatures. Thus, a prime motivation for performing M5 and M6 was to compare the safety related fuel performance characteristics of U-Fs and U-Pu-Zr. This report described conditions, results, and conclusions of testing of these fuel types

  5. Estimation of the strength of Nubian sandstone formation from point load test index and other simple parameters

    Directory of Open Access Journals (Sweden)

    Zein Abdul Karim M.

    2018-01-01

    Full Text Available This study investigates the correlation of the uniaxial compressive strength (UCS and the point load test (PLT index Is(50, bulk density, water absorption and the RQD properties of the Sudanese Nubian sandstone formation. The UCS being is the rock property needed in engineering practice but its determination is tedious, time consuming and expensive. Alternatively, the UCS may be indirectly evaluated through establishing relationships with rock parameters which are easier, cheaper and more convenient to determine in the laboratory or in the field. An extensive laboratory testing was executed to determine the above rock properties for many NSF samples taken from Khartoum State and other areas. Statistical analysis was performed on the test data and a reliable linear regression equation has been developed with a UCS to PLT Is(50 conversion factor of 10.18 and may be applied to estimate the strength of the Sudanese sandstone formation. The developed correlation is in good agreement with few of the many methods published for similar rock types which indicates that large errors may result in from applying an inappropriate UCS prediction method. Thus, it is important to establish separate correlations or validate published correlations to check their suitability for a specific rock types and local geologies. Useful correlation relationships of reasonable accuracy were also established for rough estimation of the UCS from the bulk density, water absorption and the RQD properties of the Nubian sandstone formation.

  6. The Effects of 10 Weeks Concurrent Aerobic and Strength Exercise on Quality of Life and Resilience of Kidney Transplant Patients

    Directory of Open Access Journals (Sweden)

    Elham Shakoor

    2015-09-01

    Full Text Available Background: Kidney transplant patients are exposed to a lot of different infectious on diseases because of long usage of suppressing immune system drugs.  Quality of life (QoL is generally found to improve for renal transplant recipients, although some patients continue to experience health-related problems. Kidney transplant is the selected treatment of chronic kidney disease and it improves life quality and resilience. Objective: To evaluate The Effects of 10 Weeks Concurrent Aerobic and Strength Exercise on Quality of Life and Resilience of Kidney Transplant Patients. Methods: forty four renal transplant recipients were selected to participate in the study and randomized into exercise (n=29 and control (n=15 groups. The exercise group participated in a cumulative exercise pro¬gram 3 days a week for 10 weeks in 60–90-minute exercise sessions. Control group subjects did not participate in any regular exercise activity during this period. For measuring the variable of this research; the resilience scale of Cano and Davidson (2003 and questionnaire which measured quality of life (SF-36 measured before and after 10 weeks of exercise training. Data analysis was conducted using t-tests. Results: quality of life and resilience values were significantly increased after 10 weeks of exercise training in the exercise group relative to control (P<0.05. Conclusion: ten weeks of selected low-intensity exercise can be an effective measure to improve the quality of life and resilience in renal transplant patients. Keywords: Concurrent, Aerobic and Strength Exercise, Quality of Life, Resilience, Kidney Transplant Patients

  7. Effect of grape seed extract against biodegradation of composite resin-dentin shear bond strength

    Science.gov (United States)

    Generosa, D. M.; Suprastiwi, E.; Asrianti, D.

    2017-08-01

    This study aimed to analyze the effect of grape seed extract (GSE) on resin-dentin shear bond strength. A group of 48 dentin samples were divided into 6 groups. The six groups, each with eight specimens, included group 1 (control), group 2 (control + NaOCl 10%), group 3 (2.9% GSE application before etching), group 4 (2.9% GSE application before etching + NaOCl 10%), group 5 (2.9% GSE application after etching), and group 6 (2.9% GSE application after etching + NaOCl 10%). Shear bond strengths were measured using a universal testing machine. Statistical analysis was done with the Kruskal-Wallis test and the Mann-Whitney U test. The highest median value was in group 3, and the lowest value was in group 5. GSE can improve the shear bond strength (p = 0.002 and 0.001), but it has no effect on reducing biodegradation (p = 0.141).

  8. Strength assessment of a cryostat used by the hollow electron test station.

    CERN Document Server

    Efremov, Filip

    2015-01-01

    The following report explains the work I have done on my summer student work project and the experience I have gained during the process. The work consisted of a strength assessment of a cryogenic vacuum insulated vessel according to European regulations. The cryogenic vacuum insulated vessel is used for the cooling of the solenoids. The solenoids are used in the hollow electron test station and create the magnetic fields used for testing electron guns and validating the concept of a hollow electron lens.

  9. Tensile strength and durability characteristics of high-performance fiber reinforced concrete

    International Nuclear Information System (INIS)

    Ramadoss, P.; Nagamani, K.

    2008-01-01

    This paper presents investigations towards developing a better understanding of the contribution of steel fibers to the tensile strength of high-performance fiber reinforced concrete (HPFRC). For 32 series of mixes, flexural and splitting tensile strengths were determined at 28 days. The variables investigated were fiber volume fraction (0%, 0.5%, 1% and 1.5% with an aspect of 80), silica fume replacement level (SF/CM=0.05 and 0.10) and matrix composition (w/cm ratios ranging from 0.25 t 0.40). The influence of fiber content in terms of fiber reinforcing index on the flexural and splitting tensile strengths of HPFRC is presented. Comparative studies were performed on the tensile behavior of SFRC measured by two different loading tests: flexural test and splitting test. Based on the test results, using the least square method, empirical expressions were developed to predict 28-day tensile strength of HPFRC in terms of fiber reinforcing index. Durability tests were carried out to examine the performance of the SFRC. Relationship between flexural and splitting tensile strengths has been developed using regression analysis. The experimental values of previous researchers were compared with the values predicted by the empirical equations and the absolute variation obtained was within 6% and 5% for flexural and splitting tensile strengths respectively. (author)

  10. Reliability and validity of a low load endurance strength test for upper and lower extremities in patients with fibromyalgia.

    Science.gov (United States)

    Munguía-Izquierdo, Diego; Legaz-Arrese, Alejandro

    2012-11-01

    To evaluate the reliability, standard error of the mean (SEM), clinical significant change, and known group validity of 2 assessments of endurance strength to low loads in patients with fibromyalgia syndrome (FS). Cross-sectional reliability and comparative study. University Pablo de Olavide, Seville, Spain. Middle-aged women with FS (n=95) and healthy women (n=64) matched for age, weight, and body mass index (BMI) were recruited for the study. Not applicable. The endurance strength to low loads tests of the upper and lower extremities and anthropometric measures (BMI) were used for the evaluations. The differences between the readings (tests 1 and 2) and the SDs of the differences, intraclass correlation coefficient (ICC) model (2,1), 95% confidence interval for the ICC, coefficient of repeatability, intrapatient SD, SEM, Wilcoxon signed-rank test, and Bland-Altman plots were used to examine reliability. A Mann-Whitney U test was used to analyze the differences in test values between the patient group and the control group. We hypothesized that patients with FS would have an endurance strength to low loads performance in lower and upper extremities at least twice as low as that of the healthy controls. Satisfactory test-retest reliability and SEMs were found for the lower extremity, dominant arm, and nondominant arm tests (ICC=.973-.979; P.05 for all). The Bland-Altman plots showed 95% limits of agreement for the lower extremity (4.7 to -4.5), dominant arm (3.8 to -4.4), and nondominant arm (3.9 to -4.1) tests. The endurance strength to low loads test scores for the patients with FS were 4-fold lower than for the controls in all performed tests (P<.001 for all). The endurance strength to low loads tests showed good reliability and known group validity and can be recommended for evaluating endurance strength to low loads in patients with FS. For individual evaluation, however, an improved score of at least 4 and 5 repetitions for the upper and lower extremities

  11. Heat treatment of a direct composite resin: influence on flexural strength

    Directory of Open Access Journals (Sweden)

    Caroline Lumi Miyazaki

    2009-09-01

    Full Text Available The purpose of this study was to evaluate the flexural strength of a direct composite, for indirect application, that received heat treatment, with or without investment. One indirect composite was used for comparison. For determination of the heat treatment temperature, thermogravimetric analysis (TGA and differential scanning calorimetry (DSC were performed, considering the initial weight loss temperature and glass transition temperature (Tg. Then, after photoactivation (600 mW/cm² - 40 s, the specimens (10 x 2 x 2 mm were heat-treated following these conditions: 170ºC for 5, 10 or 15 min, embedded or not embedded in investment. Flexural strength was assessed as a means to evaluate the influence of different heat treatment periods and investment embedding on mechanical properties. The data were analyzed by ANOVA and Tukey's test (α = 0.05. TGA showed an initial weight loss temperature of 180ºC and DSC showed a Tg value of 157°C. Heat treatment was conducted in an oven (Flli Manfredi, Italy, after 37°C storage for 48 h. Flexural strength was evaluated after 120 h at 37°C storage. The results showed that different periods and investment embedding presented similar statistical values. Nevertheless, the direct composite resin with treatments presented higher values (178.7 MPa compared to the indirect composite resin (146.0 MPa and the same direct composite submitted to photoactivation only (151.7 MPa. Within the limitations of this study, it could be concluded that the heat treatment increased the flexural strength of the direct composite studied, leading to higher mechanical strength compared to the indirect composite.

  12. Damage formation, fatigue behavior and strength properties of ZrO_2-based ceramics

    International Nuclear Information System (INIS)

    Kozulin, A. A.; Kulkov, S. S.; Narikovich, A. S.; Leitsin, V. N.; Kulkov, S. N.

    2016-01-01

    It is suggested that a non-destructive testing technique using a three-dimensional X-ray tomography be applied to detecting internal structural defects and monitoring damage formation in a ceramic composite structure subjected to a bending load. Three-point bending tests are used to investigate the fatigue behavior and mechanical and physical properties of medical-grade ZrO_2-based ceramics. The bending strength and flexural modulus are derived under static conditions at a loading rate of 2 mm/min. The fatigue strength and fatigue limit under dynamic loading are investigated at a frequency of 10 Hz in three stress ranges: 0.91–0.98, 0.8–0.83, and 0.73–0.77 MPa of the static bending strength. The average values of the bending strength and flexural modulus of sintered specimens are 43 MPa and 22 GPa, respectively. The mechanical properties of the ceramics are found to be similar to those of bone tissues. The testing results lead us to conclude that the fatigue limit obtained from 10"5 stress cycles is in the range 33–34 MPa, i.e. it accounts for about 75% of the static bending strength for the test material.

  13. 26 CFR 1.401(m)-2 - ACP test.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false ACP test. 1.401(m)-2 Section 1.401(m)-2 Internal... TAXES Pension, Profit-Sharing, Stock Bonus Plans, Etc. § 1.401(m)-2 ACP test. (a) Actual contribution percentage (ACP) test—(1) In general—(i) ACP test formula. A plan satisfies the ACP test for a plan year only...

  14. Alterations in strength of the shoulder rotators in young elite swimmers

    Directory of Open Access Journals (Sweden)

    Gustavo Antonio Meliscki

    Full Text Available Abstract Introduction: Shoulder muscle strength imbalance is considered a risk factor for shoulder injuries in athletes, especially in sports involving arm movements above the head. Objective: To assess the strength of the external rotators (ER and internal rotators (IR of the shoulder in elite swimmers, to determine possible differences between the dominant and non-dominant limbs, and to calculate the shoulder IR/ER ratio. Methods: Fifteen athletes participated in the study from age 20 ± 2 years, mass of 76 ± 4 kg, stature of 1.83 ± 4 cm, and BMI of 22 ± 1 kg/m2. Duration of practice of 10.74 ± 4.03 years; training frequency 5.95 ± 0.22 days/week, 2.07 ± 0.41 hours/day; and weekly number of meters swum 34.905. An isometric dynamometer (Globus Ergo System®, Codognè, Italy was used to assess ER and IR strength. Data were analyzed using descriptive statistics (mean and standard deviation, paired-sample t-test, Pearson’s correlation coefficient and the Statistical Package for Social Sciences software (SPSS, version 16.0. Results: IR and ER strength was lower in the left than in the right shoulder of the swimmers (p < 0.05. Additionally, ER strength ratio was higher than IR strength ratio (p < 0.05. Conclusion: The results showed that the swimmers had an alteration of the shoulder ER/IR ratio, especially in the dominant limb.

  15. Strength of precast concrete shear joints reinforced with high-strength wire ropes

    DEFF Research Database (Denmark)

    Joergensen, Henrik B.; Hoang, Linh Cao; Hagsten, Lars German

    2017-01-01

    This paper concerns the in-plane shear strength of connections between precast concrete wall elements reinforced with looped high-strength wire ropes. The looped wire ropes are pre-installed in so-called ‘wire boxes’ which function as shear keys. Although only a small amount of research...... on the shear strength of such connections can be found in the literature, this type of connection is increasingly being used because wire ropes are much more construction-friendly than traditional U-bars. A rigid plastic upper bound model for the shear strength of wall connections reinforced with looped wire...... ropes that are pre-installed in wire boxes is presented along with test results on the shear strength of connections with double-wire boxes. It is shown that the plastic solution agrees well with both the obtained test results and results from previously conducted tests....

  16. Strength Analysis of Coconut Fiber Stabilized Earth for Farm Structures

    Science.gov (United States)

    Enokela, O. S.; P. O, Alada

    2012-07-01

    Investigation of the strength characteristic of soil from alluvial deposit of River Benue in makurdi stabilized with coconut fiber as a stabilizer was carried as local building material for farm structure. Processed coconut fibers were mixed with the soil at four different mix ratios of 1% fiber, 2% fiber, 3% fiber and 4% fiber by percentage weight with 0% fiber as control. Compaction test and compressive strength were carried out on the various stabilizing ratio. From the compaction test, the correlation between the maximum dry density and optimum moisture content is a second order polynomial with a coefficient of 63% obtained at1.91kg/m3and 20.0% respectively while the compressive strength test shows an optimum failure load of 8.62N/mm2 at 2%fibre:100% soil mix ratio at 2.16 maximum dry density.

  17. Gender-Specific Peculiarities of Motor Preparedness of Children Aged 6-10

    Directory of Open Access Journals (Sweden)

    О. В. Іващенко

    2017-03-01

    Full Text Available The objective is to determine the gender-specific peculiarities of motor preparedness of children aged 6-10.  Materials and methods: the participants in the study were girls aged 6 (n = 36, aged 7 (n = 48, aged 8 (n = 57, aged 9 (n = 38, aged 10 (n = 46; boys aged 6 (n = 48, aged 7 (n = 45, aged 8 (n = 60, aged 9 (n = 47, aged 10 (n = 40. To achieve the tasks set, the study relied on the following research methods: analysis of scientific literature, pedagogical testing and methods of mathematical statistics of research data reduction. The study used discriminant analysis as the modeling method. Results: the classification results of motor preparedness of girls and boys aged 6-10 indicate that the study has correctly classified 81.9-100% of the initial observations. The graphic material demonstrates the density of objects within each class and a clear distinction between the classes. This allows to maintain that there is a significant difference between girls and boys aged 6-10 in their motor preparedness. Conclusions. The girls aged 6-10 show the best results in movement coordination related to combinations of movements of arms and legs, as well as flexibility. The girls aged 10 show the best results in test No. 10 “300-m Race”. The boys aged 6-10, unlike the girls, show the best results in the development of general coordination of movements, strength, speed strength, strength and general endurance. It is possible to argue with a high level of reliability that by their classification characteristics girls and boys belong to different classes, and significantly differ in motor preparedness.

  18. Effects of Different Environment Temperatures on Some Motor Characteristics and Muscle Strength

    Science.gov (United States)

    Çakir, Ergün; Yüksek, Selami; Asma, Bülent; Arslanoglu, Erkal

    2016-01-01

    The aim of this study was determine the effects of different environment temperatures on motor characteristics and muscle strength. 15 athletes participated to study. Flexibility, vertical jump, hand grip-leg strength, 30m sprint, 20-meter shuttle run and coordination-agility tests were measured in five different environment temperatures. (22°C,…

  19. Força dos músculos do assoalho pélvico e função sexual em gestantes Strength of pelvic floor muscles and sexual function during pregnancy

    Directory of Open Access Journals (Sweden)

    Joseli Franceschet

    2009-10-01

    Full Text Available CONTEXTUALIZAÇÃO: O bem-estar sexual depende de músculos do assoalho pélvico (MAP fortes o suficiente para manter a sua função. Durante a gestação, tanto a função sexual como a força dos MAP podem modificar-se. OBJETIVOS: Comparar o grau de força dos MAP e a função sexual em gestantes do segundo e terceiro trimestres. MÉTODOS: Pesquisa descritiva causal comparativa realizada com 37 gestantes de Florianópolis (18 do segundo e 19 do terceiro trimestre, com média de idade de 25,22 anos (±5,7 anos. Os instrumentos utilizados foram o Questionário Female Sexual Function Index (FSFI e o Teste Manual da Musculatura do Assoalho Pélvico, utilizando a escala de Oxford modificada para graduação da força. Os dados foram analisados por meio de estatística descritiva e inferencial (teste t independente, teste U de Mann Whitney, correlação de Spearman, nível de significância de 0,05. RESULTADOS: Não houve diferença significativa entre a média dos valores dos postos do grau de contração dos MAP de gestantes do segundo e do terceiro trimestre (U=150,5; p=0,512. Todavia, a função sexual das gestantes do segundo trimestre de gestação foi melhor que as do terceiro (U=104; p=0,042, e o grau de contração dos MAP apresentou correlações estatisticamente significativas com a idade (ρ=0,320, p=0,041 e com o escore do FSFI (ρ=0,540, pBACKGROUND: Sexual well-being depends on pelvic floor muscles (PFMs that are strong enough to maintain their function. During pregnancy, both the sexual function and the strength of the PFMs may be altered. OBJECTIVES: to compare the degree of PFM strength and the sexual function of pregnant women in the second and the third trimesters. METHODS: a descriptive, causal-comparative study was carried out with 37 pregnant women in Florianópolis (18 in the second trimester and 19 in the third trimester with a mean age of 25.22 years (±5.7 years. The instruments used were the Female Sexual Function Index

  20. Evaluation of the effects of strain rate on material properties of the high strength concrete used in nuclear facilities

    International Nuclear Information System (INIS)

    Kawaguchi, Shohei; Shirai, Koji; Takayanagi, Hideaki

    2011-01-01

    Concrete physical properties (compressive strength, tensile strength, initial elastic modulus and maximum strain) affected by strain rate weren't fully utilize for material model in dynamic response analysis for seismic and impact load because of few reports and various difficulties of impact tests. Split Hopkinson Pressure Bar (SHPB) methods are the most popular high-speed material testing and were also applied for composite material. We applied SHPB for concrete specimen and reported the strain rate effect to the concrete physical property. We used hydraulic testing device for 10 -5 /s to 10 0 /s strain rate and SHPB methods for over 10 1 /s. Four cases of concrete tests (high (50MPa at 28days)/low (35MPa at 28days) compressive strength (based on the test of exiting nuclear power facilities) and dry/wet condition) were done. And we formulated strain rate effect about compressive strength and initial elastic modulus from comparing with previous studies. (author)

  1. The significance of water ionic strength on aluminium toxicity in brown trout (Salmo trutta L.)

    Energy Technology Data Exchange (ETDEWEB)

    Alstad, Nina E.W. [Department of Biology, University of Oslo, P.O. Box 1066 Blindern, N-0316 Oslo (Norway); Kjelsberg, Birgitte M. [Department of Biology, University of Oslo, P.O. Box 1066 Blindern, N-0316 Oslo (Norway); Voellestad, L. Asbjoern [Department of Biology, University of Oslo, P.O. Box 1066 Blindern, N-0316 Oslo (Norway); Lydersen, Espen [Norwegian Institute for Water Research, P.O. Box 173 Kjelsaas, N-0411 Oslo (Norway); Poleo, Antonio B.S. [Department of Biology, University of Oslo, P.O. Box 1066 Blindern, N-0316 Oslo (Norway)]. E-mail: toni.poleo@bio.uio.no

    2005-01-01

    The toxicity of aluminium to fish is related to interactions between aluminium and the gill surface. We investigated the possible effect of water ionic strength on this interaction. The mortality of brown trout (Salmo trutta L.) exposed to three different degrees of Al polymerisation was compared in water with increased ionic strength (mean 7.31 x 10{sup -4} M) after additions of the base cations Ca{sup 2+}, Mg{sup 2+}, Na{sup +} or K{sup +}, and in water with no such addition (mean ionic strength 5.58 x 10{sup -4} M). Only a very slight ameliorating effect of increased ionic strength was observed, while the degree of Al polymerisation was of major importance in fish mortality. In addition, it was observed that smaller fish survived the Al exposures for a longer time than larger fish. We hypothesise that this is because larger fish are more susceptible to hypoxia than smaller fish. - Ionic strength has a slight ameliorating effect on Al toxicity in brown trout.

  2. The significance of water ionic strength on aluminium toxicity in brown trout (Salmo trutta L.)

    International Nuclear Information System (INIS)

    Alstad, Nina E.W.; Kjelsberg, Birgitte M.; Voellestad, L. Asbjoern; Lydersen, Espen; Poleo, Antonio B.S.

    2005-01-01

    The toxicity of aluminium to fish is related to interactions between aluminium and the gill surface. We investigated the possible effect of water ionic strength on this interaction. The mortality of brown trout (Salmo trutta L.) exposed to three different degrees of Al polymerisation was compared in water with increased ionic strength (mean 7.31 x 10 -4 M) after additions of the base cations Ca 2+ , Mg 2+ , Na + or K + , and in water with no such addition (mean ionic strength 5.58 x 10 -4 M). Only a very slight ameliorating effect of increased ionic strength was observed, while the degree of Al polymerisation was of major importance in fish mortality. In addition, it was observed that smaller fish survived the Al exposures for a longer time than larger fish. We hypothesise that this is because larger fish are more susceptible to hypoxia than smaller fish. - Ionic strength has a slight ameliorating effect on Al toxicity in brown trout

  3. Reliability of using nondestructive tests to estimate compressive strength of building stones and bricks

    Directory of Open Access Journals (Sweden)

    Ali Abd Elhakam Aliabdo

    2012-09-01

    Full Text Available This study aims to investigate the relationships between Schmidt hardness rebound number (RN and ultrasonic pulse velocity (UPV versus compressive strength (fc of stones and bricks. Four types of rocks (marble, pink lime stone, white lime stone and basalt and two types of burned bricks and lime-sand bricks were studied. Linear and non-linear models were proposed. High correlations were found between RN and UPV versus compressive strength. Validation of proposed models was assessed using other specimens for each material. Linear models for each material showed good correlations than non-linear models. General model between RN and compressive strength of tested stones and bricks showed a high correlation with regression coefficient R2 value of 0.94. Estimation of compressive strength for the studied stones and bricks using their rebound number and ultrasonic pulse velocity in a combined method was generally more reliable than using rebound number or ultrasonic pulse velocity only.

  4. R and D of low activated Fe-Mn-Cr high strength non-magnetic steel, (I). Screening test for constituent optimization and fundamental characterization test

    Energy Technology Data Exchange (ETDEWEB)

    Ishiyama, Shintaro; Fukaya, Kiyoshi; Eto, Motokuni; Kikuchi, Mituru [Japan Atomic Energy Research Inst., Tokyo (Japan); Sato, Ikuo; Kusuhashi, Mikio; Hatakeyama, Tuyoshi [Japan Steel Works Ltd., Tokyo (Japan); Takahashi, Heishitiro [Center for Advanced Research of Energy Technology, Hokkaido Univ., Sapporo (Japan)

    2000-02-01

    It is very important to develop low activated/non-magnetic materials as large scale structural materials for fusion reactors. In the structural design of JT-60SU, low activated/non-magnetic materials with high specific strength and low decay heat characterizations are required. In the present paper, a new low activated/non-magnetic material (15.5 Mn-16Cr-0.2N-0.3Si-0.2C (wt%)) based on the conventional high manganese steel with lower Ni, CO, C, N and Mn contents for the purpose of lower activation and decay heat was developed and the mass production conditions of the material were optimized. Fundamental material characterization tests of the new material developed in present study were carried out, and the following conclusions are derived ; (1) Lower activation characterizations with the new materials in the order of 1/10 of that of SUS316L steel, (2) Higher strength of the material in the order of 2{approx}3 of SUS316L steel and (3) Lower decay heat with higher thermal conductivity with comparison of SUS316L steel. (author)

  5. The effect of increasing strength and approach velocity on triple jump performance.

    Science.gov (United States)

    Allen, Sam J; Yeadon, M R Fred; King, Mark A

    2016-12-08

    The triple jump is an athletic event comprising three phases in which the optimal phase ratio (the proportion of each phase to the total distance jumped) is unknown. This study used a planar whole body torque-driven computer simulation model of the ground contact parts of all three phases of the triple jump to investigate the effect of strength and approach velocity on optimal performance. The strength and approach velocity of the simulation model were each increased by up to 30% in 10% increments from baseline data collected from a national standard triple jumper. Increasing strength always resulted in an increased overall jump distance. Increasing approach velocity also typically resulted in an increased overall jump distance but there was a point past which increasing approach velocity without increasing strength did not lead to an increase in overall jump distance. Increasing both strength and approach velocity by 10%, 20%, and 30% led to roughly equivalent increases in overall jump distances. Distances ranged from 14.05m with baseline strength and approach velocity, up to 18.49m with 30% increases in both. Optimal phase ratios were either hop-dominated or balanced, and typically became more balanced when the strength of the model was increased by a greater percentage than its approach velocity. The range of triple jump distances that resulted from the optimisation process suggests that strength and approach velocity are of great importance for triple jump performance. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Investigation of test methods for measuring compressive strength and modulus of two-dimensional carbon-carbon composites

    Science.gov (United States)

    Ohlhorst, Craig W.; Sawyer, James Wayne; Yamaki, Y. Robert

    1989-01-01

    An experimental evaluation has been conducted to ascertain the the usefulness of two techniques for measuring in-plane compressive failure strength and modulus in coated and uncoated carbon-carbon composites. The techniques involved testing specimens with potted ends as well as testing them in a novel clamping fixture; specimen shape, length, gage width, and thickness were the test parameters investigated for both coated and uncoated 0/90 deg and +/-45 deg laminates. It is found that specimen shape does not have a significant effect on the measured compressive properties. The potting of specimen ends results in slightly higher measured compressive strengths than those obtained with the new clamping fixture. Comparable modulus values are obtained by both techniques.

  7. Ultrafine Structure and High Strength in Cold-Rolled Martensite

    DEFF Research Database (Denmark)

    Huang, Xiaoxu; Morito, S.; Hansen, Niels

    2012-01-01

    Structural refinement by cold rolling (10 to 80 pct reductions) of interstitial free (IF) steel containing Mn and B has been investigated from samples with different initial structures: (a) lath martensite, (b) coarse ferrite (grain size 150 mu m), and (c) fine ferrite (22 mu m). Unalloyed IF steel....... At low to medium strains, lath martensite transforms into a cell block structure composed of cell block boundaries and cell boundaries with only a negligible change in strength. At medium to large strains, cell block structures in all samples refine with increasing strain and the hardening rate...... is constant (stage IV). A strong effect of the initial structure is observed on both the structural refinement and the strength increase. This effect is largest in lath martensite and smallest in unalloyed ferrite. No saturation in structural refinement and strength is observed. The discussion covers...

  8. BNL NONLINEAR PRE TEST SEISMIC ANALYSIS FOR THE NUPEC ULTIMATE STRENGTH PIPING TEST PROGRAM

    International Nuclear Information System (INIS)

    DEGRASSI, G.; HOFMAYER, C.; MURPHY, C.; SUZUKI, K.; NAMITA, Y.

    2003-01-01

    The Nuclear Power Engineering Corporation (NUPEC) of Japan has been conducting a multi-year research program to investigate the behavior of nuclear power plant piping systems under large seismic loads. The objectives of the program are: to develop a better understanding of the elasto-plastic response and ultimate strength of nuclear piping; to ascertain the seismic safety margin of current piping design codes; and to assess new piping code allowable stress rules. Under this program, NUPEC has performed a large-scale seismic proving test of a representative nuclear power plant piping system. In support of the proving test, a series of materials tests, static and dynamic piping component tests, and seismic tests of simplified piping systems have also been performed. As part of collaborative efforts between the United States and Japan on seismic issues, the US Nuclear Regulatory Commission (USNRC) and its contractor, the Brookhaven National Laboratory (BNL), are participating in this research program by performing pre-test and post-test analyses, and by evaluating the significance of the program results with regard to safety margins. This paper describes BNL's pre-test analysis to predict the elasto-plastic response for one of NUPEC's simplified piping system seismic tests. The capability to simulate the anticipated ratcheting response of the system was of particular interest. Analyses were performed using classical bilinear and multilinear kinematic hardening models as well as a nonlinear kinematic hardening model. Comparisons of analysis results for each plasticity model against test results for a static cycling elbow component test and for a simplified piping system seismic test are presented in the paper

  9. Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

    Science.gov (United States)

    Wollin, Martin; Purdam, Craig; Drew, Michael K

    2016-01-01

    To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting. Reliability study. Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle. Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0. This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  10. Effects of Strength of Accent on an L2 Interactive Lecture Listening Comprehension Test

    Science.gov (United States)

    Ockey, Gary J.; Papageorgiou, Spiros; French, Robert

    2016-01-01

    This article reports on a study which aimed to determine the effect of strength of accent on listening comprehension of interactive lectures. Test takers (N = 21,726) listened to an interactive lecture given by one of nine speakers and responded to six comprehension items. The test taker responses were analyzed with the Rasch computer program…

  11. High-Temperature Tensile Strength of Al10Co25Cr8Fe15Ni36Ti6 Compositionally Complex Alloy (High-Entropy Alloy)

    Science.gov (United States)

    Daoud, H. M.; Manzoni, A. M.; Wanderka, N.; Glatzel, U.

    2015-06-01

    Homogenizing at 1220°C for 20 h and subsequent aging at 900°C for 5 h and 50 h of a novel Al10Co25Cr8Fe15Ni36Ti6 compositionally complex alloy (high-entropy alloy) produces a microstructure consisting of an L12 ordered γ' phase embedded in a face-centered cubic solid-solution γ matrix together with needle-like B2 precipitates (NiAl). The volume fraction of γ' phase is ~46% and of needle-like B2 precipitates database; Thermo-Calc Software, Stockholm, Sweden). The high-temperature tensile tests were carried out at room temperature, 600°C, 700°C, 800°C, and 1000°C. The tensile strength as well as the elongation to failure of both heat-treated specimens is very high at all tested temperatures. The values of tensile strength has been compared with literature data of well-known Alloy 800H and Inconel 617, and is discussed in terms of the observed microstructure.

  12. Methods, strengths, weaknesses, and limitations of bioequivalence tests with special regard to immunosuppressive drugs.

    Science.gov (United States)

    van Gelder, Teun; Gabardi, Steven

    2013-08-01

    Within the field of solid organ transplantation, the patents for a number of immunosuppressive drugs have expired in the last few years. Tacrolimus, cyclosporine, and mycophenolate mofetil are now available as generic drugs. In some countries, the market penetration of these generic formulations is as high as 70%, whereas in some other countries, this figure is below 10%. Several professional societies have published position papers on the risks and benefits of generic substitution of immunosuppressive drugs. It often appears that transplant professionals are not fully aware of the requirements for registration of generic drugs. This article describes the registration requirements with a focus on bioequivalence testing, the strengths and weaknesses in this process, and the differences between Europe and the US. © 2013 The Authors Transplant International © 2013 European Society for Organ Transplantation. Published by Blackwell Publishing Ltd.

  13. Influence of ultraviolet irradiation treatment on porcelain bond strength of titanium surfaces.

    Science.gov (United States)

    Kumasaka, Tomonari; Ohno, Akinori; Hori, Norio; Hoshi, Noriyuki; Maruo, Katsuichiro; Kuwabara, Atsushi; Seimiya, Kazuhide; Toyoda, Minoru; Kimoto, Katsuhiko

    2018-01-26

    To determine the effect of titanium (Ti) surface modification by ultraviolet irradiation (UVI) on the bond strength between Ti and porcelain. Grade 2 Ti plates were allotted to five groups: sandblasted (SA), 15 min UVI (UV), SA+5 min UVI (SA+UV5), SA+10 min UVI (SA+UV10), and SA+15 min UVI (SA+UV15). After surface treatment, porcelain was added. A precious metal (MC) was used for comparison with Ti. The effects of 24-h storage at room temperature versus thermal cycling only at 5 and 55°C in water were evaluated. Subsequently, the tensile strength of each sample was tested. Data were analyzed using one-way analysis of variance and the Tukey test. In both the room temperature and thermal cycling groups, the MC and SA+15 min UVI samples showed significantly greater bond strengths than the other samples (pbond strength between porcelain and the Ti surface.

  14. Influence of Compositional Variations on Floc Size and Strength

    Science.gov (United States)

    Yin, H.; Tan, X.; Reed, A. H.; Furukawa, Y.; Zhang, G.

    2010-12-01

    Clay-biopolymer micro aggregates or flocs are abundant in waters, including rivers, lakes, and oceans. Owing to their small size and charged surfaces, fine-grained inorganic sediment particles, mainly clays, interact actively with organic substances, such as organic matter and biogenic polymers, to form aggregates or flocs, typically in the size of 10-1000 μm. The flocs in ocean waters are also termed “marine snow”. These flocs are typically porous, tenuous, and soft in nature. During transport in suspension, they may breakdown and decrease in size if the turbulent shear stress exceeds their strength. They may also collide and form larger ones if the shear stress is relatively small. Since flocs of different size and structure settle at different velocities, understanding their strength is also of essential importance for sediment hydrodynamics, transport, and management. Our study focuses on investigating the influence of compositional variations on floc size and strength so that a better understanding of floc dynamics can be achieved. A laser diffraction-based Cilas® particle size and shape analyzer with controllable fluid circulation velocity was employed to conduct floc size measurements and shape imaging, the latter achieved by a high resolution inverted optical microscope, which is also installed with the size analyzer. Totally two clay minerals, kaolinite and illite, were tested as the model inorganic solid skeleton minerals for floc formation, and two biopolymers, anionic xanthan gum and neutral guar gum, were chosen as analogs of naturally occurring organic matter or biopolymers to simulate clay-biopolymer floc formation. Moreover, the concentration of both organic and inorganic phases was varied. The floc breakage or tensile strength was indirectly estimated by the varied fluid flow velocity in the particle size analyzer’s circulation system. For each individual composition, stable flocs were formed by three different fluid circulating velocities

  15. The effects of long term strength training on hemodynamic parameters and resistin level in postmenopausal women

    Directory of Open Access Journals (Sweden)

    Cecília Tardivo Marin

    2014-05-01

    Full Text Available Objective: Investigate the influence of strength training (ST on serum resistin levels and blood pressure of postmenopausal women. Methods: Longitudinal study conducted at the Federal University of São Carlos with twenty-three sedentary postmenopausal women. The ST lasted 13 months (Dec./2008 to Jan./2010 and consisted of two weekly sessions with three sets of 8-12 maximum repetitions and one exercise for each main muscle group. Maximum muscular strength was tested in the following exercises: bench press, 45° leg press, and standing arm curl. Serum resistin level was determined using the ELISA method. ANOVA (with repeated measures was used for the comparisons between periods Pre-, 6 months and 13 months (p < 0.05; Pearson’s correlation test was used to evaluate the correlations between resistin × blood pressure, resistin × muscle strength and strength × blood pressure. Results: Women presented the following anthropometric profile: 61.33±3.8 years; height 148.5±32.7 cm; body mass 67.56±10.85 kg. The ST decreased resistin levels (30272.4 ± 8100.1 to 16350.6 ± 2404.6 pg/mL and systolic blood pressure (120.5 ± 11.8 to 115.8 ± 1.6 mmHg, and increased muscular strength in the leg press 45o (172.3 ± 27.3 to 348.6 ± 40.8kg, bench press (31.9 ± 4.1 to 41.8 ± 5.6 kg and arm curl (21.0 ± 2.4 to 26.5 ± 2.9 kg after 13 months (p < 0.05. Conclusion: The results of this study revealed that long-term ST increases maximum muscular strength, decreases systolic blood pressure and serum resistin levels, which are beneficial physiological alterations that reduce the risk for cardiovascular diseases in postmenopausal women. doi:10.5020/18061230.2013.p325

  16. Short-Term Effects of Combined High-Intensity Strength and Sprint Interval Training on Anthropometric Characteristics and Physical Performance of Elite Team Handball Players.

    Science.gov (United States)

    Hermassi, Souhail; Chelly, Mohamed Souhail; Fieseler, Georg; Bartels, Thomas; Schulze, Stephan; Delank, Karl-Stefan; Shepard, Roy J; Schwesig, René

    2017-12-01

    Muscular strength and speed are critical physical factors in determining the technical and tactical skills of elite team handball players. This study thus investigated the effect of high-intensity muscular strength and sprint interval training (SIT) on lower limb explosive performance and anthropometric characteristics in 22 male handball athletes aged 20.2 ± 0.1 years. A training group (TG, n = 12) and a control group (CG, n = 10) were followed over 8 weeks parallel to regular handball training. The TG received combined additional high-intensity muscular strength and interval training twice per week during this period. The muscular training was comprised of 3 - 4 sets of 70 - 85 % of 1-RM (repetition maximum) of dynamic back half squat exercise; followed immediately by a short sprint program with 4, 5, and 6 maximal intensity repetitions of 30 m runs. Strength (1-RM of the half back-squat and bench press), first step (V1S), first 5 m (V5 m), squat jumps (SJ), counter movement jumps (CMJ) and the Modified Agility Test (MAT) were tested at the beginning and end of the study. Significant interaction effects (group × time) were observed for all parameters (η² range: 0.531 (MAT) to 0.829 (First 5 m)). All 10 parameters showed relevant intervention effects (d> 0.5) in the TG (highest intervention effect: CMJ: d = 4.05), the mean effect size being d = 1.85. In contrast, scores for the CG either remained unchanged or decreased (d = -0.24). We conclude that combined high-intensity strength and sprint interval training during the competitive season should be recommended to elite male handball players as a means of improving handball-related performance characteristics without compromising other critical aspects of the individual's performance. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Biomechanical Analysis of an Arthroscopic Broström Ankle Ligament Repair and a Suture Anchor-Augmented Repair.

    Science.gov (United States)

    Giza, Eric; Whitlow, Scott R; Williams, Brady T; Acevedo, Jorge I; Mangone, Peter G; Haytmanek, C Thomas; Curry, Eugene E; Turnbull, Travis Lee; LaPrade, Robert F; Wijdicks, Coen A; Clanton, Thomas O

    2015-07-01

    Secondary surgical repair of ankle ligaments is often indicated in cases of chronic lateral ankle instability. Recently, arthroscopic Broström techniques have been described, but biomechanical information is limited. The purpose of the present study was to analyze the biomechanical properties of an arthroscopic Broström repair and augmented repair with a proximally placed suture anchor. It was hypothesized that the arthroscopic Broström repairs would compare favorably to open techniques and that augmentation would increase the mean repair strength at time zero. Twenty (10 matched pairs) fresh-frozen foot and ankle cadaveric specimens were obtained. After sectioning of the lateral ankle ligaments, an arthroscopic Broström procedure was performed on each ankle using two 3.0-mm suture anchors with #0 braided polyethylene/polyester multifilament sutures. One specimen from each pair was augmented with a 2.9-mm suture anchor placed 3 cm proximal to the inferior tip of the lateral malleolus. Repairs were isolated and positioned in 20 degrees of inversion and 10 degrees of plantarflexion and loaded to failure using a dynamic tensile testing machine. Maximum load (N), stiffness (N/mm), and displacement at maximum load (mm) were recorded. There were no significant differences between standard arthroscopic repairs and the augmented repairs for mean maximum load and stiffness (154.4 ± 60.3 N, 9.8 ± 2.6 N/mm vs 194.2 ± 157.7 N, 10.5 ± 4.7 N/mm, P = .222, P = .685). Repair augmentation did not confer a significantly higher mean strength or stiffness at time zero. Mean strength and stiffness for the arthroscopic Broström repair compared favorably with previous similarly tested open repair and reconstruction methods, validating the clinical feasibility of an arthroscopic repair. However, augmentation with an additional proximal suture anchor did not significantly strengthen the repair. © The Author(s) 2015.

  18. Strength, Deformation and Friction of in situ Rock

    Science.gov (United States)

    1974-12-01

    Kayenta sandstone, Mixed Company site, Colorado. 30 21. Strength as a function of density for specimen cored perpendicular and parallel to bedding. 30...saturation. 33 24. Photomicrograph of Kayenta sandstone (x 30). 35 25. Stress difference as a function of density for triaxial tests up to P = 4.0...specimen size on strength for Kayenta sandstone, Mixed Company site Colorado. m Sä £ 3 s Q 3/« In, j. O 2 In. X ’ X3/4(n.ll • 2ln. II it

  19. The Effects of Whole-Body Vibration on the Cross-Transfer of Strength

    Directory of Open Access Journals (Sweden)

    Alicia M. Goodwill

    2012-01-01

    Full Text Available This study investigated whether the use of superimposed whole-body vibration (WBV during cross-education strength training would optimise strength transfer compared to conventional cross-education strength training. Twenty-one healthy, dominant right leg volunteers (21±3 years were allocated to a strength training (ST, m=3, f=4, a strength training with WBV (ST + V, m=3, f=4, or a control group (no training, m=3, f=4. Training groups performed 9 sessions over 3 weeks, involving unilateral squats for the right leg, with or without WBV (35 Hz; 2.5 mm amplitude. All groups underwent dynamic single leg maximum strength testing (1RM and single and paired pulse transcranial magnetic stimulation (TMS prior to and following training. Strength increased in the trained limb for the ST (41%; ES=1.14 and ST + V (55%; ES=1.03 groups, which resulted in a 35% (ES=0.99 strength transfer to the untrained left leg for the ST group and a 52% (ES=0.97 strength transfer to the untrained leg for the ST + V group, when compared to the control group. No differences in strength transfer between training groups were observed (P=0.15. For the untrained leg, no differences in the peak height of recruitment curves or SICI were observed between ST and ST + V groups (P=1.00. Strength training with WBV does not appear to modulate the cross-transfer of strength to a greater magnitude when compared to conventional cross-education strength training.

  20. Strength resistance test of superior members for elderly people: comparison between dumbbells with different weights

    Directory of Open Access Journals (Sweden)

    Lucélia Justino Borges

    2008-07-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2008v10n3p261 The aim of the study was to compare the performance of elderly people in the strength resistance test of superior members (SRTSM with dumbbells of different weights (1,8 kg and 2 kg for women and 3,6 kg and 4 kg for men. The sample consisted of 407 elderly (349 feminine and 58 masculine, with age of 60 to 88 years, practitioners of physical exercise for at least six months. The used instrument was the SRTSM of the battery of tests American Alliance for Health, Physical Education, Recreation and Dance (AAHPERD. Two executions of the test were carried through with dumbbells of different weights, SRTSM (1,8 kg and 3,6 kg and “adjusted” SRTSM (2 kg and 4 kg. For the analysis of the data, it was proceeded descriptive analysis, test t of Student for independent samples, paired t test for dependent samples and ANOVA with post-hoc of Tukey, adopting itself the 5% level significance. The results demonstrated that the use of dumbbells with 4 weights of 2 and kg, seem not to affect the performance of the elderly ones, mainly of the masculine sex. For the feminine sex significant difference in the averages of the second comparison carried through for the sort was detected. However, this difference can have been resulting from external factors to the test, since, the greater average obtained was for “the adjusted” SRTSM. Nevertheless, one tries to facilitate even more the evaluation of the functional capacity of the elderly population, being recommended for SRTSM the use of dumbbells with weight of 2 kg for women and 4kg for men that they are of low cost, easy acquisition and access in the Brazilian market.

  1. Influence of Fatigue on Tackling Ability in Rugby League Players: Role of Muscular Strength, Endurance, and Aerobic Qualities.

    Directory of Open Access Journals (Sweden)

    Tim J Gabbett

    Full Text Available This study investigated the influence of repeated high-intensity effort exercise on tackling ability in rugby league players, and determined the relationship between physical qualities and tackling ability under fatigued conditions in these athletes. Eleven semi-professional rugby league players underwent measurements of speed (10 m and 40 m sprint, upper-body strength (4 repetition maximum [RM] bench press and weighted chin-up, upper-body muscular endurance (body mass maximum repetition chin-up, body mass maximum repetition dips, lower-body strength (4RM squat, and estimated maximal aerobic power (multi-stage fitness test. Tackling ability was assessed using a standardized one-on-one tackling test, before, during, and following four bouts of repeated high-intensity effort (RHIE exercise. The relationship between physical qualities and fatigue-induced decrements in tackling ability were determined using Pearson product moment correlation coefficients. Each cycle of the RHIE protocol induced progressive reductions in tackling ability. A moderate reduction (Effect Size = ~-1.17 ± 0.60, -34.1 ± 24.3% in tackling ability occurred after the fourth cycle of the RHIE protocol. Players with greater relative lower-body strength (i.e. 4RM squat/kg had the best tackling ability under fatigued conditions (r = 0.72, p = 0.013. There were no significant relationships between tackling ability under fatigued conditions and any other physical quality. These findings suggest that lower-body strength protects against fatigue-induced decrements in tackling ability. The development of lower-body strength should be a priority to facilitate the development of robust tackling skills that are maintained under fatigue.

  2. Bond strength of etch-and-rinse and self-etch adhesive systems to enamel and dentin irradiated with a novel CO2 9.3 μm short-pulsed laser for dental restorative procedures.

    Science.gov (United States)

    Rechmann, Peter; Bartolome, N; Kinsel, R; Vaderhobli, R; Rechmann, B M T

    2017-12-01

    The objective of this study was to evaluate the influence of CO 2 9.3 μm short-pulsed laser irradiation on the shear bond strength of composite resin to enamel and dentin. Two hundred enamel and 210 dentin samples were irradiated with a 9.3 µm carbon dioxide laser (Solea, Convergent Dental, Inc., Natick, MA) with energies which either enhanced caries resistance or were effective for ablation. OptiBond Solo Plus [OptiBondTE] (Kerr Corporation, Orange, CA) and Peak Universal Bond light-cured adhesive [PeakTE] (Ultradent Products, South Jordan, UT) were used. In addition, Scotchbond Universal [ScotchbondSE] (3M ESPE, St. Paul, MN) and Peak SE self-etching primer with Peak Universal Bond light-cured adhesive [PeakSE] (Ultradent Products) were tested. Clearfil APX (Kuraray, New York, NY) was bonded to the samples. After 24 h, a single plane shear bond test was performed. Using the caries preventive setting on enamel resulted in increased shear bond strength for all bonding agents except for self-etch PeakSE. The highest overall bond strength was seen with PeakTE (41.29 ± 6.04 MPa). Etch-and-rinse systems achieved higher bond strength values to ablated enamel than the self-etch systems did. PeakTE showed the highest shear bond strength with 35.22 ± 4.40 MPa. OptiBondTE reached 93.8% of its control value. The self-etch system PeakSE presented significantly lower bond strength. The shear bond strength to dentin ranged between 19.15 ± 3.49 MPa for OptiBondTE and 43.94 ± 6.47 MPa for PeakSE. Etch-and-rinse systems had consistently higher bond strength to CO 2 9.3 µm laser-ablated enamel. Using the maximum recommended energy for dentin ablation, the self-etch system PeakSE reached the highest bond strength (43.9 ± 6.5 MPa).

  3. Nondestructive testing of the low-level radioactive waste drums for uni-axial compressive strength and free liquid content

    International Nuclear Information System (INIS)

    Yu Geping; Chang Mingyu; Wang Yeajeng; Chu, David S.L.; Ju Yihzen

    1992-01-01

    This paper summarizes the nondestructive test to determine the uni-axial compressive strength and free water content of solidified low level radioactive waste. The uni-axial compressive strength is determined by ultrasonic wave propagation speed, and the results are compared with those of compressive tests. Three methods of detecting the surface free water by ultrasonic testing are established, the ultrasonic wave speed, wave form and pulse height are used to determine the existence and amount of the surface free liquid. Possible difficulties are discussed. (author)

  4. High-strength chromium--molybdenum rails

    International Nuclear Information System (INIS)

    Smith, Y.E.; Sawhill, J.M. Jr.; Cias, W.W.; Eldis, G.T.

    1976-01-01

    A laboratory study was conducted with the aim of developing an as-rolled rail of over 100 ksi (689 N/mm 2 ) yield strength. A series of compositions providing both pearlitic and bainitic microstructures was evaluated. A fine pearlitic structure was developed in a 0.73 percent C -- 0.83 percent Mn -- 0.16 percent Si -- 0.75 percent Cr -- 0.21 percent Mo steel by simulating the mill cooling rate of 132-lb/yd (65.5-kg/m) rail. Two 100-ton commercial heats were made of this approximate composition and processed into 132-lb/yd (65.5-kg/m) rail. Samples tested in the laboratory ranged from 109 to 125 ksi (750 to 860 N/mm 2 ) in yield strength. The chromium-molybdenum rails also exhibited excellent fracture toughness and fatigue properties. Sections of the rail were joined by both flash-butt welding and thermite welding. The hardness peaks produced in the flash-butt welds could be reduced by applying either a postweld current or an induction heating cycle. The high-strength chromium-molybdenum rails have been in service for over eight months in curved sections of an ore railway that carries over 55 million gross long tons per year. 7 tables, 18 figs

  5. The role of testing realism on experimentally obtained stereotype strength.

    Science.gov (United States)

    Hoffmann, Errol R; Whitfield, Richard C

    2011-01-01

    It has been shown (Hoffmann 2009) that pencil-and-paper tests, when used to determine stereotype strength, may yield data quite different to that obtained from hardware tests. The purpose of this research was to determine the level of realism required in order to have stereotypes that are consistent with real-world values. It is surprising that there does not appear to be any published research addressing this problem; all previous researches have considered either paper/pencil or hardware tests or sometimes both, but no level of simulation in between these techniques. In order to determine the effect of level of testing realism, a specific example was chosen to test, that of water tap operation stereotypes. Tests used verbal questioning, photographs of tap arrangements, a partial hardware arrangement and finally a full hardware setup. The results of these four levels of realism were very different and illustrated that, only with a full realistic simulation, did participants respond as might be expected in a real-world environment, illustrating the importance of testing realism when determining population stereotypes. This result has strong implications for product designers when selecting appropriate layouts of displays and controls and the linkages relating these. Copyright © 2010 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  6. Application of Quantitative MRI for Brain Tissue Segmentation at 1.5 T and 3.0 T Field Strengths

    Science.gov (United States)

    West, Janne; Blystad, Ida; Engström, Maria; Warntjes, Jan B. M.; Lundberg, Peter

    2013-01-01

    Background Brain tissue segmentation of white matter (WM), grey matter (GM), and cerebrospinal fluid (CSF) are important in neuroradiological applications. Quantitative Mri (qMRI) allows segmentation based on physical tissue properties, and the dependencies on MR scanner settings are removed. Brain tissue groups into clusters in the three dimensional space formed by the qMRI parameters R1, R2 and PD, and partial volume voxels are intermediate in this space. The qMRI parameters, however, depend on the main magnetic field strength. Therefore, longitudinal studies can be seriously limited by system upgrades. The aim of this work was to apply one recently described brain tissue segmentation method, based on qMRI, at both 1.5 T and 3.0 T field strengths, and to investigate similarities and differences. Methods In vivo qMRI measurements were performed on 10 healthy subjects using both 1.5 T and 3.0 T MR scanners. The brain tissue segmentation method was applied for both 1.5 T and 3.0 T and volumes of WM, GM, CSF and brain parenchymal fraction (BPF) were calculated on both field strengths. Repeatability was calculated for each scanner and a General Linear Model was used to examine the effect of field strength. Voxel-wise t-tests were also performed to evaluate regional differences. Results Statistically significant differences were found between 1.5 T and 3.0 T for WM, GM, CSF and BPF (p3.0 T. The mean differences between 1.5 T and 3.0 T were -66 mL WM, 40 mL GM, 29 mL CSF and -1.99% BPF. Voxel-wise t-tests revealed regional differences of WM and GM in deep brain structures, cerebellum and brain stem. Conclusions Most of the brain was identically classified at the two field strengths, although some regional differences were observed. PMID:24066153

  7. The Effect of Gap Angle on Tensile Strength of Preceramic Base Metal Solder Joints.

    Science.gov (United States)

    Fattahi, Farnaz; Hashemi Ardakani, Zahra; Hashemi Ardakani, Maryam

    2015-12-01

    Soldering is a process commonly used in fabricating dental prosthesis. Since most soldered prosthesis fail at the solder joints; the joint strength is of utmost importance. The purpose of this study was to evaluate the effect of gap angle on the tensile strength of base metal solder joints. A total number of 40 Ni-Cr samples were fabricated according to ADA/ISO 9693 specifications for tensile test. Samples were cut at the midpoint of the bar, and were placed at the considered angles by employing an explicitly designed device. They were divided into 4 groups regarding the gap angle; Group C (control group) with parallel gap on steady distance of 0.2mm, Group 1: 10°, Group 2: 20°, and Group3: 30° gap angles. When soldered, the specimens were all tested for tensile strength using a universal testing machine at a cross-head speed of 0.5 mm/min with a preload of 10N. Kruskal-Wallis H test was used to compare tensile strength among the groups (ptensile strength values obtained from the study groups were respectively 307.84, 391.50, 365.18, and 368.86 MPa. The tensile strength was not statistically different among the four groups in general (p≤ 0.490). Making the gap angular at the solder joints and the subsequent unsteady increase of the gap distance would not change the tensile strength of the joint.

  8. Dielectric strength test to protection elements for live lines works

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Pinto-Salamanca

    2017-06-01

    Full Text Available This paper presents the design and assembly of a system of tests of sustained voltage to elements and equipment used in live line maneuvers through tests on gloves and dielectric rods, as these are the first points of contact to ensure safe operations. It means an advance for the creation of a laboratory certified in this type of tests at Universidad Pedagógica y Tecnológica de Colombia (UPTC Faculty of Duitama, considering that currently there are not laboratories that provide this service in Boyacá and Casanare. Dielectric strength tests were performed on personal protection elements and equipment under the parameters of ASTM D120, ASTM F496, ISO 60903, ASTM-F711 and IEEE 978, developing an assembly for testing gloves and dielectric rods with voltage levels up to 15 kV. The results validate the proposed system to outlook of circuit design and implementation, where tests were performed to establish dielectric capacities, in operating under open circuit conditions, with resistive load or short circuit. The compliance with the regulations established under the test sequences of safety parameters for the system and the follow-up to the tests was verified through the use of a management system for the generation of concepts of approval or rejection of the tested elements.

  9. An evaluation of the +/-45 deg tensile test for the determination of the in-plane shear strength of composite materials

    Science.gov (United States)

    Kellas, S.; Morton, J.; Jackson, K. E.

    1991-01-01

    The applicability of the +/-45 deg tensile test for the determination of the in-plane shear strength of advanced composite laminates is studied. The assumptions used for the development of the shear strength formulas were examined, and factors such as the specimen geometry and stacking sequence were assessed experimentally. It was found that the strength of symmetric and balanced +/-45 deg laminates depends primarily upon the specimen thickness rather than the specimen width. These findings have important implications for the +/-45 deg tensile test which is recommended by several organizations for the determination of the in-plane shear stress/strain response and the shear strength of continuous fiber reinforced composites. Modifications to the recommended practices for specimen selection and shear strength determination are suggested.

  10. Comparisons of low-intensity versus moderate-intensity combined aerobic and resistance training on body composition, muscle strength, and functional performance in older women.

    Science.gov (United States)

    Shiotsu, Yoko; Yanagita, Masahiko

    2018-06-01

    This study aimed to examine the effects of exercise order of combined aerobic and low- or moderate-intensity resistance training into the same session on body composition, functional performance, and muscle strength in healthy older women. Furthermore, this study compared the effects of different (low- vs moderate-) intensity combined training. A total of 60 healthy older women (age 61-81 y) were randomly assigned to five groups that performed aerobic exercise before low-intensity resistance training (AR-L, n = 12) or after resistance training (RA-L, n = 12), performed aerobic exercise before moderate-intensity resistance training (AR-M, n = 12) or after resistance training (RA-M, n = 12), or nonintervention control conditions (CON, n = 12). Body composition, functional performance, and muscle strength were evaluated before and after the 10-week training. No effects of exercise order of combined aerobic and low- or moderate-intensity resistance training (AR-L vs RA-L, AR-M vs RA-M) were observed in body composition, functional performance, or muscle strength, whereas the effects of training intensity of combined training (AR-L vs AR-M, RA-L vs RA-M) were observed on functional performance. All combined trainings significantly increased muscle strength and gait ability (P Functional reach test significantly increased in the AR-M and RA-M groups (P training increases muscle strength and improves gait ability, regardless of the exercise order. Also, greater improvement in dynamic balance capacity, a risk factor associated with falling, is observed in moderate-intensity combined training.

  11. Ultimate Tensile Strength as a Function of Test Rate for Various Ceramic Matrix Composites at Elevated Temperatures

    Science.gov (United States)

    Choi, Sung R.; Bansal, Narottam P.; Gyekenyesi, John P.

    2002-01-01

    Ultimate tensile strength of five different continuous fiber-reinforced ceramic composites, including SiC/BSAS (2D 2 types), SiC/MAS-5 (2D), SiC/SiC (2D enhanced), and C/SiC(2D) was determined as a function of test rate at I 100 to 1200 'C in air. All five composite materials exhibited a significant dependency of ultimate strength on test rate such that the ultimate strength decreased with decreasing test rate, similar to the behavior observed in many advanced monolithic ceramics at elevated temperatures. The application of the preloading technique as well as the prediction of life from one loading configuration (constant stress rate) to another (constant stress loading) for SiC/BSAS suggested that the overall macroscopic failure mechanism of the composites would be the one governed by a power-law type of damage evolution/accumulation, analogous to slow crack growth commonly observed in advanced monolithic ceramics.

  12. LEU WWR-M2 fuel assemblies burnable test

    International Nuclear Information System (INIS)

    Kirsanov, G.A.; Konoplev, K.A.; Pikulik, R.G.; Sajkov, Yu. P.; Tchmshkyan, D.V.; Tedoradze, L.V.; Zakharov, A.S.

    2000-01-01

    The results of in-pile irradiation tests of LEU WWR-M2 fuel assemblies with reduced enrichment of fuel are submitted in the report. The tests are made according to the Russian Program on Reduced Enrichment for Research and Test Reactors (RERTR). United States Department of Energy and the Ministry of Atomic Energy of Russian Federation jointly fund this Program. The irradiation tests of 5 WWR-M2 experimental assemblies are carried out at WWR-M reactor of the Petersburg Nuclear Physics Institute (PNPI). The information on assembly design and technique of irradiation tests is presented. In the irradiation tests the integrity of fuel assemblies is periodically measured. The report presents the data for the integrity maintained during the burnup of 5 fuel assemblies up to 45%. These results demonstrate the high reliability of the experimental fuel assemblies within the guaranteed burnup limits specified by the manufacturer. The tests are still in progress; it is planned to test and analyze the change in integrity for burnup of up to 70% - 75% or more. LEU WWR-M2 fuel assemblies are to be offered for export by their Novosibirsk manufacturer. Currently, HEU WWR-M2 fuel assemblies are used in Hungary, Ukraine and Vietnam. LEU WWR-M2 fuel assemblies were designed as a possible replacement for the HEU WWR-M2 fuel assemblies in those countries, but their use can be extended to other research reactors. (author)

  13. Validation of a new strength measurement device for amyotrophic lateral sclerosis clinical trials.

    Science.gov (United States)

    Andres, Patricia L; Skerry, Linda M; Munsat, Theodore L; Thornell, Brenda J; Szymonifka, Jackie; Schoenfeld, David A; Cudkowicz, Merit E

    2012-01-01

    Strength measures with reduced variability and higher sensitivity could improve efficiency in clinical trials of amyotrophic lateral sclerosis (ALS). The Accurate Test of Limb Isometric Strength (ATLIS) was developed to precisely and conveniently measure force in 12 muscle groups. In this study we evaluate the reliability and validity of the ATLIS testing protocol. Twenty healthy adults and 10 patients with ALS were tested twice by the same or by different evaluators to determine test-retest and interrater reliability. Twenty healthy adults were examined using ATLIS and a well-validated strength testing protocol (TQNE) to assess criterion-based validity. Mean absolute variation between tests was 8.6%, and intraclass correlation coefficients for each muscle group were high (range 0.82-0.99). The Pearson correlation coefficient of mean ATLIS and TQNE scores was 0.90. A subject survey demonstrated high user acceptance of ATLIS. ATLIS is convenient for patients and evaluators, produces precise strength measurements, and is easily moved between examining rooms. Copyright © 2011 Wiley Periodicals, Inc.

  14. Effect of prior silane application on the bond strength of a universal adhesive to a lithium disilicate ceramic.

    Science.gov (United States)

    Moro, André Fábio Vasconcelos; Ramos, Amanda Barreto; Rocha, Gustavo Miranda; Perez, Cesar Dos Reis

    2017-11-01

    Universal adhesives combine silane and various monomers in a single bottle to make them more versatile. Their adhesive performance is unclear. The purpose of this in vitro study was to assess the effects of an additional silane application before using a universal adhesive on the adhesion between a disilicate glass ceramic and a composite resin by using a microshear bond strength test (μSBS) and fracture analysis immediately and after thermocycling. One hundred lithium disilicate glass ceramic disks were divided into 10 groups for bond strength testing according to the following 3 surface treatments: silane application (built-in universal adhesive or with additional application), adhesive (Adper Single Bond Plus [SB, 3M ESPE], Scotchbond Universal Adhesive [U, 3M ESPE], and mixed U with Dual Cure Activator [DCA, 3M ESPE]); or thermocycling (half of the specimens were thermocycled 10000 times). After surface treatment, 5 resin cylinders were bonded to each disk and submitted to a μSBS test. The failure mode was analyzed under a stereomicroscope and evaluated by scanning electron microscope and energy-dispersive x-ray spectroscopy. Data from the μSBS test were analyzed by 3-way ANOVA followed by the Tukey HSD post hoc test (α=.05). An additional silane application resulted in a higher μSBS result for all adhesive groups (Padhesives, which may be improved with an additional silane application. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. Effects of reclaimed asphalt pavement on indirect tensile strength test of conditioned foamed asphalt mix

    International Nuclear Information System (INIS)

    Katman, Herda Yati; Norhisham, Shuhairy; Ismail, Norlela; Ibrahim, Mohd Rasdan; Matori, Mohd Yazip

    2013-01-01

    This paper presents the results of Indirect Tensile Strength (ITS) Test for samples prepared with reclaimed asphalt pavement (RAP). Samples were conditioned in water at 25°C for 24 hours prior to testing. Results show that recycled aggregate from reclaimed asphalt pavement performs as well as virgin aggregate.

  16. Experimental Study on the Compressive Strength of Big Mobility Concrete with Nondestructive Testing Method

    Directory of Open Access Journals (Sweden)

    Huai-Shuai Shang

    2012-01-01

    Full Text Available An experimental study of C20, C25, C30, C40, and C50 big mobility concrete cubes that came from laboratory and construction site was completed. Nondestructive testing (NDT was carried out using impact rebound hammer (IRH techniques to establish a correlation between the compressive strengths and the rebound number. The local curve for measuring strength of the regression method is set up and its superiority is proved. The rebound method presented is simple, quick, and reliable and covers wide ranges of concrete strengths. The rebound method can be easily applied to concrete specimens as well as existing concrete structures. The final results were compared with previous ones from the literature and also with actual results obtained from samples extracted from existing structures.

  17. [Effects of different concentrations of MgSiF(6) as electrolyte for micro-arc oxidation on the bond strength between titanium and porcelain].

    Science.gov (United States)

    Yuan, M J; Zhang, S J; Liu, J; Tan, F

    2018-02-09

    Objective: To investigate the effects of different concentrations of MgSiF(6) as electrolyte on the bond strength between titanium and porcelain after micro-arc oxidation (MAO) treatment and screen the suitable concentration of MgSiF(6) that can improve the bond strength between titanium and porcelain. Methods: Four different concentrations of MgSiF(6) (10, 20, 30, 40 g/L) were chosen as MAO reaction solutions. Sandblasting treatment was selected as a control group. After porcelain was fused to each specimen, titanium-porcelain bond strengths were evaluated by the three-point bending test according to ISO 9693. Scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) were adopted to evaluate the morphologies and elemental compositions of both the MAO coatings and the interfaces of the titanium-porcelain restoration. Results: The surface of titanium specimen in the control group was sharp and rough, while specimens in both 10 g/L group and 20 g/L group were porous and homogeneous. However, the pores found on the specimens in the latter group were larger in diameter (approximately 1.0-2.0 μm) than those on the former one (0.2-0.5 μm). The bond strengths of the control group and the experimental groups (10, 20, 30, 40 g/L MgSiF(6)) were (27.08±3.16), (38.18±2.65), (44.75±2.21), (36.44±2.04), (31.04±2.59) MPa, respectively. All the experimental groups showed higher bond strengths than the control group did ( Pporcelain were tight and compact in the 20 g/L group, while different amounts of pores and cracks were visible in the other groups. Additionally, after the three-point bending test, few residual porcelains could be observed on the surfaces of specimens in the control group. Conclusions: MAO treatment with 20 g/L MgSiF(6) on titanium can improve bonding strength between titanium and porcelain.

  18. Comparison of shear test methods for evaluating the bond strength of resin cement to zirconia ceramic.

    Science.gov (United States)

    Kim, Jae-Hoon; Chae, Soyeon; Lee, Yunhee; Han, Geum-Jun; Cho, Byeong-Hoon

    2014-11-01

    This study compared the sensitivity of three shear test methods for measuring the shear bond strength (SBS) of resin cement to zirconia ceramic and evaluated the effects of surface treatment methods on the bonding. Polished zirconia ceramic (Cercon base, DeguDent) discs were randomly divided into four surface treatment groups: no treatment (C), airborne-particle abrasion (A), conditioning with Alloy primer (Kuraray Medical Co.) (P) and conditioning with Alloy primer after airborne-particle abrasion (AP). The bond strengths of the resin cement (Multilink N, Ivoclar Vivadent) to the zirconia specimens of each surface treatment group were determined by three SBS test methods: the conventional SBS test with direct filling of the mold (Ø 4 mm × 3 mm) with resin cement (Method 1), the conventional SBS test with cementation of composite cylinders (Ø 4 mm × 3 mm) using resin cement (Method 2) and the microshear bond strength (μSBS) test with cementation of composite cylinders (Ø 0.8 mm × 1 mm) using resin cement (Method 3). Both the test method and the surface treatment significantly influenced the SBS values. In Method 3, as the SBS values increased, the coefficients of variation decreased and the Weibull parameters increased. The AP groups showed the highest SBS in all of the test methods. Only in Method 3 did the P group show a higher SBS than the A group. The μSBS test was more sensitive to differentiating the effects of surface treatment methods than the conventional SBS tests. Primer conditioning was a stronger contributing factor for the resin bond to zirconia ceramic than was airborne-particle abrasion.

  19. Strengths only or strengths and relative weaknesses? A preliminary study.

    Science.gov (United States)

    Rust, Teri; Diessner, Rhett; Reade, Lindsay

    2009-10-01

    Does working on developing character strengths and relative character weaknesses cause lower life satisfaction than working on developing character strengths only? The present study provides a preliminary answer. After 76 college students completed the Values in Action Inventory of Strengths (C. Peterson & M. E. P. Seligman, 2004), the authors randomly assigned them to work on 2 character strengths or on 1 character strength and 1 relative weakness. Combined, these groups showed significant gains on the Satisfaction With Life Scale (E. Diener, R. A. Emmons, R. J. Larsen, & S. Griffin, 1985), compared with a 32-student no-treatment group. However, there was no significant difference in gain scores between the 2-strengths group and the 1-character-strength-and-1-relative-character-weakness group. The authors discuss how focusing on relative character weaknesses (along with strengths) does not diminish-and may assist in increasing-life satisfaction.

  20. Cable tray ultimate strength test employing a large shaker table

    Energy Technology Data Exchange (ETDEWEB)

    Komatsu, K.; Myojin, K.; Imai, K. [The Kansai Electric Power Co., Osaka (Japan); Fuyama, H. [Mitsubishi Heavy Industries Ltd, Takasago (Japan); Kokubo, E. [Mitsubishi Heavy Industdries Ltd, Kobe (Japan)

    2004-07-01

    Ultimate behaviors of cable trays, used in nuclear plants, have not been well studied since cable trays are designed based on conservative design criteria. In this study, by employing a large shaker table, an ultimate strength test was conducted for cable trays used in nuclear power plants. This report describes the results of shaker table test. The following results were obtained. First, in an S{sub 2} earthquake, the damping ratio was so large - more than 30% due to the rubbing of cables - that a large response was not present and the strains in the support were within the elastic limits. Secondly, the support was strong enough to sustain the cable trays even when the strain in the support was 20 times larger than the elastic limit. (authors)

  1. Test method research on weakening interface strength of steel - concrete under cyclic loading

    Science.gov (United States)

    Liu, Ming-wei; Zhang, Fang-hua; Su, Guang-quan

    2018-02-01

    The mechanical properties of steel - concrete interface under cyclic loading are the key factors affecting the rule of horizontal load transfer, the calculation of bearing capacity and cumulative horizontal deformation. Cyclic shear test is an effective method to study the strength reduction of steel - concrete interface. A test system composed of large repeated direct shear test instrument, hydraulic servo system, data acquisition system, test control software system and so on is independently designed, and a set of test method, including the specimen preparation, the instrument preparation, the loading method and so on, is put forward. By listing a set of test results, the validity of the test method is verified. The test system and the test method based on it provide a reference for the experimental study on mechanical properties of steel - concrete interface.

  2. Tensile strength and fatigue strength of 6061 aluminum alloy friction welded joints

    Energy Technology Data Exchange (ETDEWEB)

    Ochi, H.; Tsujino, R. [Osaka Inst. of Tech., Asahi-ku Osaka (Japan); Sawai, T. [Osaka Sangyo Univ., Daito (Japan); Yamamoto, Y. [Setsunan Univ., Neyagawa (Japan); Ogawa, K. [Osaka Prefecture Univ., Sakai (Japan); Suga, Y. [Keio Univ., Kohoku-ku, Yokohama (Japan)

    2002-07-01

    Friction welding of 6061 aluminum alloy was carried out in order to examine the relationship between deformation heat input in the upset stage and joint performance. The joint performance was evaluated by tensile testing and fatigue testing. Stabilized tensile strength was obtained when the deformation heat input in the upset stage exceeded 200 J/s. Weld condition at the weld interface and the width of softened area affected fatigue strength more than tensile strength. That is, when the weld condition at the weld interface is good and the softened area is wide, fatigue strength increases. On the other hand, when the weld condition at the weld interface is good and the softened area is narrow, and when the weld condition at the weld interface is somewhat poor in spite of the wide softened area, fatigue strength decreases. The fatigue limit obtained by the fatigue testing revealed that, when the deformation heat input in the upset stage exceeded a certain value, sound joints could be produced. (orig.)

  3. Ego depletion in color priming research: self-control strength moderates the detrimental effect of red on cognitive test performance.

    Science.gov (United States)

    Bertrams, Alex; Baumeister, Roy F; Englert, Chris; Furley, Philip

    2015-03-01

    Colors have been found to affect psychological functioning. Empirical evidence suggests that, in test situations, brief perceptions of the color red or even the word "red" printed in black ink prime implicit anxious responses and consequently impair cognitive performance. However, we propose that this red effect depends on people's momentary capacity to exert control over their prepotent responses (i.e., self-control). In three experiments (Ns = 66, 78, and 130), first participants' self-control strength was manipulated. Participants were then primed with the color or word red versus gray prior to completing an arithmetic test or an intelligence test. As expected, self-control strength moderated the red effect. While red had a detrimental effect on performance of participants with depleted self-control strength (ego depletion), it did not affect performance of participants with intact self-control strength. We discuss implications of the present findings within the current debate on the robustness of priming results. © 2015 by the Society for Personality and Social Psychology, Inc.

  4. Damage formation, fatigue behavior and strength properties of ZrO{sub 2}-based ceramics

    Energy Technology Data Exchange (ETDEWEB)

    Kozulin, A. A., E-mail: kozulyn@ftf.tsu.ru; Kulkov, S. S. [Tomsk State University, Tomsk, 634050 (Russian Federation); Narikovich, A. S.; Leitsin, V. N. [Immanuel Kant Baltic Federal University, Kaliningrad, 236041 (Russian Federation); Kulkov, S. N., E-mail: kulkov@ispms.ru [Tomsk State University, Tomsk, 634050 (Russian Federation); Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation)

    2016-08-02

    It is suggested that a non-destructive testing technique using a three-dimensional X-ray tomography be applied to detecting internal structural defects and monitoring damage formation in a ceramic composite structure subjected to a bending load. Three-point bending tests are used to investigate the fatigue behavior and mechanical and physical properties of medical-grade ZrO{sub 2}-based ceramics. The bending strength and flexural modulus are derived under static conditions at a loading rate of 2 mm/min. The fatigue strength and fatigue limit under dynamic loading are investigated at a frequency of 10 Hz in three stress ranges: 0.91–0.98, 0.8–0.83, and 0.73–0.77 MPa of the static bending strength. The average values of the bending strength and flexural modulus of sintered specimens are 43 MPa and 22 GPa, respectively. The mechanical properties of the ceramics are found to be similar to those of bone tissues. The testing results lead us to conclude that the fatigue limit obtained from 10{sup 5} stress cycles is in the range 33–34 MPa, i.e. it accounts for about 75% of the static bending strength for the test material.

  5. Design, Fabrication, Test Report of the Material Capsule(08M-10K) with Double Thermal Media for High-temperature Irradiation

    International Nuclear Information System (INIS)

    Cho, Man Soon; Choo, K. N.; Kang, Y. H.; Sohn, J. M.; Shin, Y. T.; Park, S. J.; Kim, B. G.; Oh, S. Y.

    2010-01-01

    To overcome the restriction of the irradiation test at a high temperature of the existing material capsule with Al thermal media, a capsule suitable for the irradiation at the high temperature was developed and the performance test was undertaken. The 08M-10K capsule was designed and fabricated as that with double thermal media to verify the structural and external integrity in the high-temperature irradiation higher than 500 .deg. C. The thermal performance test was undertaken at the out-pile test facility, and the soundness of the double thermal media was confirmed with the naked eye after disassembling the capsule. Though the temperatures of the specimens reach 500±20 .deg. C as a result maintaining the capsule during 5 hours after setting the specimens temperatures in the target range, the high-temperature thermal media with double structure was confirmed to maintain the soundness. And the specimens and the thermal media were heated to 600 .deg. C for about 3 minutes, but the thermal media were maintained sound. Especially, the Al thermal media were heated for 5 hours in range of 500±20 .deg. C and for 3 minutes at the temperature of 600 .deg. C. However, the thermal media were confirmed to maintain the soundness. Whether a capsule has only Al thermal media or the high-temperature thermal media with double structure, any capsule can be used in the range of 500±20 .deg. C as the result of this experiment maintaining the specimens high-temperature

  6. Results of MACE tests M0 and M1

    International Nuclear Information System (INIS)

    Spencer, B.W.; Farmer, M.T.; Armstrong, D.R.; Kilsdonk, D.J.; Aeschlimann, R.W.; Fischer, M.

    1992-01-01

    This document discusses the Melt Attack and Coolability Experiment (MACE) Program underway at Argonne National Laboratory under ACE/EPRI sponsorship. The program addresses the efficacy of water to terminate an accident situation if melt progression were to result in a molten core/concrete interaction (MCCI) in the reactor containment. Large-scale experiments are being conducted in parallel with related modeling efforts, involving the addition of water to an MCI already underway. The experiments utilize UO 2 /ZrO 2 /Zr corium mixtures, direct electrical heating for simulation of decay heating, and various types of concrete basemats. Currently the tests involve 430 kg corium mass, 25 cm depth, in a 50 cm square test section. Test MO was a successful scoping test, but the first full size test, Ml, failed to achieve melt-water contact owing to existence of a preexisting bridge crust of corium charge. A heat flux of 3.5 MW/m 2 was measured in MO which removed energy from the corium pool equivalent to its entire heat of solidification prior to abatement by formation of an interfacial crust. The crust subsequently limited heat extraction to 600 kW/m 2 and less. Both tests MO and Ml revealed physical evidence of large pool swelling events which resulted in extrusion (and ejection) of melt into water above the crust, significantly increasing the overall quench and reducing the remaining melt in contact with the concrete. Furthermore, test Ml provided evidence of occasional ''burst mode'' ablation events and one additional important benefit of overlying water -- aerosol capture

  7. Mechanical strength of various cyanate ester/epoxy insulation systems after reactor irradiation

    International Nuclear Information System (INIS)

    Prokopec, R.; Humer, K.; Maix, R.K.; Fillunger, H.; Weber, H.W.

    2006-01-01

    In order to ensure safety operation of the magnet coils, the insulation system must keep its mechanical strength over the whole magnet lifetime under the appropriate radiation environment. Recent results on cyanate ester/epoxy blends demonstrated their mechanical integrity after irradiation to the ITER design fluence level, i.e. 1 x 10 22 m -2 (E > 0.1 MeV). For economic reasons, the cyanate ester content in the blend should be kept as low as possible due to the higher price compared to traditional epoxy resins. Therefore, the optimal composition of cyanate ester and epoxy in the blend is of great importance. In this study R-glass fiber/ Kapton reinforced cyanate ester based blends using different epoxy resins and epoxy contents were investigated. Short-beam shear as well as static tensile tests were carried out at 77 K prior to and after irradiation to a fast neutron fluence of 1 and 2 x 10 22 m -2 (E > 0.1 MeV) in the TRIGA reactor (Vienna) at ambient temperature (340 K). In addition, tension-tension fatigue measurements were performed in the load and the strain controlled mode in order to simulate the pulsed operation conditions of the ITER magnets. Initial results show, that cyanate ester contents of both 40 % and 30 % lead only to a small reduction of the mechanical strength after irradiation to the ITER design fluence. (author)

  8. Dynamics of muscle strength improvement during isokinetic rehabilitation of athletes with ACL rupture and chondromalacia patellae.

    Science.gov (United States)

    Desnica Bakrac, N

    2003-03-01

    To assess quantitatively dynamics and extent of the increase in muscle strength during isokinetic rehabilitation. daily measurements of muscle strength; detailed testing at the beginning and at the end of rehabilitation. Cybex Rehabilitation Center, Zagreb. 44 athletes (31 m, 13 F, age 16-35), 3 injury-defined groups: athletes with ACL rupture (non-reconstructed and reconstructed) and chondromalacia patellae. all subjects underwent isokinetic rehabilitation on Cybex Orthotron KT2 device, using individually designed protocols (extension and flexion exercises, concentric muscle contractions, 15 treatments). monitoring of daily progress on rehabilitation device and detailed testing on diagnostic device. All patients showed considerable improvement. Muscle strength improved on average 141% (SD=110) in ACL-reconstructed group, 144% (SD=130) for chondromalacia patellae group and 150% (SD=74) for ACL-non-reconstructed group, comparing to initial strength. Dynamic status tested on Cybex Otrhotron diagnostic device prior and after rehabilitation strongly correlated with final progress monitored on the rehabilitation device. Isokinetic rehabilitation is a quick and effective method in treating knee injuries in athletes. Both types of objective criteria have shown significant increase in muscle strength. The improvement of muscle strength was on the average 149% (SD=101), which is about 10% daily for 15 treatments. The greatest progress, 19% per day, occurred during first five days. The athletes were able to resume their sport activities as follows: patients from chondromalacia patellae group, and most of them from the non-reconstructed ACL group were back in competition within a month, while 75% from the ACL reconstructed group came back within 3 months, and the rest of them within 5 months.

  9. Effects of influent strength on microorganisms in surface flow mesocosm wetlands.

    Science.gov (United States)

    Tao, Wendong; Hall, Ken J; Ramey, William

    2007-11-01

    To choose an appropriate dilution ratio to treat woodwaste leachate without inhibition on heterotrophic bacteria, microbial ATP concentration and the rates of heterotrophic leucine incorporation and acetate uptake were compared across surface flow mesocosm wetlands fed with different strengths of influent. Abundances of protozoa and respiring bacteria were investigated in two mesocosm wetlands to elucidate the effects of influent strength on heterotrophic bacteria. The strongest influent or the raw leachate did not show a significant inhibitory effect on leucine incorporation and acetate uptake. Instead, leucine incorporation rates by bacteria in water, epiphytic biofilm and sediment were higher in mesocosm wetlands fed with a stronger influent. There were significantly more respiring planktonic bacteria (451 x 10(5) mL(-1)) and fewer nanoflagellates (3.8 x 10(3) mL(-1)) in the mesocosm fed with a strong influent, while fewer respiring planktonic bacteria (38.7 x 10(5)mL(-1)) and more nanoflagellates (15.4 x 10(3) mL(-1)) in the mesocosm fed with a weak influent. The majority of the total microbial ATP was attributed to sedimentary bacteria, of which >96% were inactive. Heterotrophic activity and its distribution among water, epiphytic biofilm and sediment in the mesocosm wetlands were affected by availability of bacterial substrates and grazing pressure of nanoflagellates.

  10. Core stability training on lower limb balance strength.

    Science.gov (United States)

    Dello Iacono, Antonio; Padulo, Johnny; Ayalon, Moshe

    2016-01-01

    This study aimed to assess the effects of core stability training on lower limbs' muscular asymmetries and imbalances in team sport. Twenty footballers were divided into two groups, either core stability or control group. Before each daily practice, core stability group (n = 10) performed a core stability training programme, while control group (n = 10) did a standard warm-up. The effects of the core stability training programme were assessed by performing isokinetic tests and single-leg countermovement jumps. Significant improvement was found for knee extensors peak torque at 3.14 rad · s(-1) (14%; P core stability group. The jump tests showed a significant reduction in the strength asymmetries in core stability group (-71.4%; P = 0.02) while a concurrent increase was seen in the control group (33.3%; P core exercises for optimal lower limbs strength balance development in young soccer players.

  11. Synthesis and characterization of grinding aid fly ash blended mortar effect on bond strength of masonry prisms

    Science.gov (United States)

    Krishnaraj, L.; Ravichandran, P. T.; Sagadevan, Suresh

    2018-04-01

    The aim of the present work is to study the effect of particle size reduction by applying top-down nanotechnology such as ball mill grinding process with the addition of amine-based grinding aids. The particle size reduction in synthesis process and its characterization were investigated for fly ash particles. The Rosin-Rammler-Bennet (RRB) distribution model using mathematical formulations were studied for fly ash ground particles. The hardened properties of grinding aid fly ash composite mortar were studied using compressive strength test. The optimum grinding time was 120 min identified through the particle size distribution analysis. The mean particle size decreased from 92.09 μm to 10.5 μm in which there is 89% reduction in particle size due to the grinding of fly ash particle with grinding aids. The compressive strength results show that substitutions of Ordinary Portland Cement (OPC) mortar by Amine-based Grinding aid Fly Ash (AGFA) 15% gives 12, 23% and at 30% gives 6, 8% of higher strength compare to the substitutions of raw fly ash. The addition of grinding aids in grinding process gives more advantages to reduce the particle size without changing chemical composition. The AGFA sample shows better performance in compressive strength and bond strength behavior of masonry prism. It may suggest that amine based grinding aids play a vital role and feasible to use in fly ash grinding process.

  12. Constraints on the OH-to-H Abundance Ratio in Infrared-bright Galaxies Derived from the Strength of the OH 35 μm Absorption Feature

    Science.gov (United States)

    Stone, Myra; Veilleux, Sylvain; González-Alfonso, Eduardo; Spoon, Henrik; Sturm, Eckhard

    2018-02-01

    We analyze Spitzer/InfraRed Spectrograph (IRS) observations of the OH 35 μm feature in 15 nearby (z ≲ 0.06) (ultra-)luminous infrared galaxies (U/LIRGs). All objects exhibit OH 35 μm purely in absorption, as expected. The small optical depth of this transition makes the strength of this feature a good indicator of the true OH column density. The measured OH 35 μm equivalent widths imply an average OH column density and a 1-σ standard deviation to the mean of {N}{OH}=1.31+/- 0.22× {10}17 cm‑2. This number is then compared with the hydrogen column density for a typical optical depth at 35 μm of ∼0.5 and gas-to-dust ratio of 125 to derive an OH-to-H abundance ratio of {X}{OH}=1.01+/- 0.15× {10}-6. This abundance ratio is formally a lower limit. It is consistent with the values generally assumed in the literature. The OH 35 μm line profiles predicted from published radiative transfer models constrained by observations of OH 65, 79, 84, and 119 μm in 5 objects (Mrk 231, Mrk 273, IRAS F05189-2524, IRAS F08572+3915, and IRAS F20551-4250) are also found to be consistent with the IRS OH 35 μm spectra.

  13. Effects of Muscle Strength and Balance Control on Sit-to-Walk and Turn Durations in the Timed Up and Go Test.

    Science.gov (United States)

    Chen, Tzurei; Chou, Li-Shan

    2017-12-01

    To examine the association of muscle strength and balance control with the amount of time taken to perform sit-to-walk (STW) or turning components of the Timed Up and Go (TUG) test in older adults. Correlations; multiple regression models. General community. Older adults (N=60) age >70 years recruited from the community. Not applicable. Muscle strength, balance control, and TUG test performance time. Muscle strength was quantified by peak joint moments during the isometric maximal voluntary contraction test for bilateral hip abductors, knee extensors, and ankle plantar flexors. Balance control was assessed with the Berg Balance Scale, Fullerton Advanced Balance Scale, and center of mass and ankle inclination angle derived during the TUG test performance. We found that balance control measures were significantly associated with both STW and turning durations even after controlling for muscle strength and other confounders (STW duration: Pbalance control is an important factor that contributes to longer STW and turning durations on the TUG test. Furthermore, strength has a higher association with STW than turning duration. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  14. Strength and ductility of Ni3Al alloyed with boron and substitutional elements

    International Nuclear Information System (INIS)

    Ishikawa, K.; Aoki, K.; Masumoto, T.

    1995-01-01

    The effect of simultaneous alloying of boron (B) and the substitutional elements M on mechanical properties of Ni 3 Al was investigated by the tensile test at room temperature. The yield strength of Ni 3 Al+B increases by alloying with M except for Fe and Ga. In particular, it increases by alloying with Hf, Nb, W, Ta, Pd and Si. The fracture strength of Ni 3 Al+B increases by alloying with Pd, Ga, Si and Hf, but decreases with the other elements. Elongation of Ni 3 Al+B increases by alloying with Ga, Fe and Pd, but decreases with other elements. Hf and Pd is the effective element for the increase of the yield strength and the fracture strength of Ni 3 Al+B, respectively. Alloying with Hf leads to the increases of the yield strength and the fracture strength of Ni 3 Al+B, but to the lowering of elongation. On the other hand, alloying with Pd improves all mechanical properties, i.e. the yield strength, the fracture strength and elongation. On the contrary, alloying with Ti, V and Co leads to the lowering of mechanical properties of Ni 3 Al+B. The reason why ductility of Ni 3 Al+B is reduced by alloying with some elements M is discussed

  15. Evaluating Upper-Body Strength and Power From a Single Test: The Ballistic Push-up.

    Science.gov (United States)

    Wang, Ran; Hoffman, Jay R; Sadres, Eliahu; Bartolomei, Sandro; Muddle, Tyler W D; Fukuda, David H; Stout, Jeffrey R

    2017-05-01

    Wang, R, Hoffman, JR, Sadres, E, Bartolomei, S, Muddle, TWD, Fukuda, DH, and Stout, JR. Evaluating upper-body strength and power from a single test: the ballistic push-up. J Strength Cond Res 31(5): 1338-1345, 2017-The purpose of this study was to examine the reliability of the ballistic push-up (BPU) exercise and to develop a prediction model for both maximal strength (1 repetition maximum [1RM]) in the bench press exercise and upper-body power. Sixty recreationally active men completed a 1RM bench press and 2 BPU assessments in 3 separate testing sessions. Peak and mean force, peak and mean rate of force development, net impulse, peak velocity, flight time, and peak and mean power were determined. Intraclass correlation coefficients were used to examine the reliability of the BPU. Stepwise linear regression was used to develop 1RM bench press and power prediction equations. Intraclass correlation coefficient's ranged from 0.849 to 0.971 for the BPU measurements. Multiple regression analysis provided the following 1RM bench press prediction equation: 1RM = 0.31 × Mean Force - 1.64 × Body Mass + 0.70 (R = 0.837, standard error of the estimate [SEE] = 11 kg); time-based power prediction equation: Peak Power = 11.0 × Body Mass + 2012.3 × Flight Time - 338.0 (R = 0.658, SEE = 150 W), Mean Power = 6.7 × Body Mass + 1004.4 × Flight Time - 224.6 (R = 0.664, SEE = 82 W); and velocity-based power prediction equation: Peak Power = 8.1 × Body Mass + 818.6 × Peak Velocity - 762.0 (R = 0.797, SEE = 115 W); Mean Power = 5.2 × Body Mass + 435.9 × Peak Velocity - 467.7 (R = 0.838, SEE = 57 W). The BPU is a reliable test for both upper-body strength and power. Results indicate that the mean force generated from the BPU can be used to predict 1RM bench press, whereas peak velocity and flight time measured during the BPU can be used to predict upper-body power. These findings support the potential use of the BPU as a valid method to evaluate upper-body strength and power.

  16. Micro-shear bond strength of resin cement to dentin after application of desensitizing toothpastes.

    Science.gov (United States)

    Bavbek, Andac Barkin; Goktas, Baris; Cekic-Nagas, Isil; Egilmez, Ferhan; Ergun, Gulfem; Eskitascioglu, Gurcan

    2013-01-01

    The aim of the study was to evaluate the effect of three desensitizing toothpastes on bonding of resin cements to dentin. The occlusal surfaces of 72 maxillary third molars were ground to obtain flat dentin surfaces and then divided into three groups according to three desensitizing toothpastes used: Sensodyne Rapid Relief (GlaxoSmithKline, SmithKline Beecham Ltd., Slough, UK), Signal Sensitive Expert (Unilever Sanayi ve Ticaret Türk A.Ş., Ümraniye, İstanbul, Turkey) and Colgate Sensitive Pro-Relief (Colgate Palmolive, New York, NY). Following bonding of the resin cement (Clearfil™ SA Cement, Kuraray Co, Osaka, Japan) to dentin, the specimens were light cured for 40 s with a LED (Elipar S10, 3M Espe, St. Paul, MN). The strength measurements were accomplished with a micro-shear testing machine (Bisco, Schaumburg, IL) at a cross-head speed of 0.5 mm/min until the failure occurs. Failure modes were examined using a stereomicroscope and scanning electron microscope. The data were analyzed with one-way analysis of variance (ANOVA) and Tukey HSD test (α = 0.05). ANOVA revealed that the application of desensitizing toothpastes had significant effects on bond strength of the resin cement tested to dentin (p < 0.05). Mixed failures were observed in all of the groups. The use of a desensitizing toothpaste before cementation might alter the bond strength of adhesively luted restorations.

  17. Influence of steel fibers on the shear and flexural performance of high-strength concrete beams tested under blast loads

    Science.gov (United States)

    Algassem, O.; Li, Y.; Aoude, H.

    2017-09-01

    This paper presents the results of a study examining the effect of steel fibres on the blast behaviour of high-strength concrete beams. As part of the study, a series of three large-scale beams built with high-strength concrete and steel fibres are tested under simulated blast loading using the shock-tube testing facility at the University of Ottawa. The specimens include two beams built with conventional high-strength concrete (HSC) and one beam built with high-strength concrete and steel fibres (HSFRC). The effect of steel fibres on the blast behaviour is examined by comparing the failure mode, mid-span displacements and, overall blast resistance of the specimens. The results show that the addition of steel fibres in high-strength concrete beams can prevent shear failure and substitute for shear reinforcement if added in sufficient quantity. Moreover, the use of steel fibres improves flexural response under blast loading by reducing displacements and increasing blast capacity. Finally, the provision of steel fibres is found to improve the fragmentation resistance of high-strength concrete under blast loads.

  18. Impact strength of small icy bodies that experienced multiple collisions

    Science.gov (United States)

    Yasui, Minami; Hayama, Ryo; Arakawa, Masahiko

    2014-05-01

    Frequent collisions are common for small bodies in the Solar System, and the cumulative damage to these bodies is thought to significantly affect their evolution. It is important to study the effects of multiple impacts such as the number of impacts on the impact strength and the ejection velocity of impact fragments. Here we conducted multiple-impact experiments using a polycrystalline water ice target, varying the number of impacts from 1 to 10 times. An ice cylindrical projectile was impacted at 84-502 m s-1 by using a single-stage gas gun in a cold room between -10 and -15 °C. The impact strength of the ice target that experienced a single impact and multiple impacts is expressed by the total energy density applied to the same target, ΣQ, and this value was observed to be 77.6 J kg-1. The number of fine impact fragments at a fragment mass normalized by an initial target mass, m/Mt0 ∼ 10-6, nm, had a good correlation with the single energy density at each shot, Qj, and the relationship was shown to be nm=10·Qj1.31±0.12. We also estimated the cumulative damage of icy bodies as a total energy density accumulated by past impacts, according to the crater scaling laws proposed by Housen et al. (Housen, K.R., Schmidt, R.M., Holsapple, K.A. [1983]. J. Geophys. Res. 88, 2485-2499) of ice and the crater size distributions observed on Phoebe, a saturnian icy satellite. We found that the cumulative damage of Phoebe depended significantly on the impact speed of the impactor that formed the craters on Phoebe; and the cumulative damage was about one-third of the impact strength ΣQ* at 500 m s-1 whereas it was almost zero at 3.2 km s-1.

  19. Nanoparticle transport in water-unsaturated porous media: effects of solution ionic strength and flow rate

    International Nuclear Information System (INIS)

    Prédélus, Dieuseul; Lassabatere, Laurent; Louis, Cédric; Gehan, Hélène; Brichart, Thomas; Winiarski, Thierry; Angulo-Jaramillo, Rafael

    2017-01-01

    This paper presents the influence of ionic strength and flow on nanoparticle (NP) retention rate in an unsaturated calcareous medium, originating from a heterogeneous glaciofluvial deposit of the region of Lyon (France). Laboratory columns 10 cm in diameter and 30 cm in length were used. Silica nanoparticles (Au-SiO 2 -FluoNPs), with hydrodynamic diameter ranging from 50 to 60 nm and labeled with fluorescein derivatives, were used to simulate particle transport, and bromide was used to characterize flow. Three flow rates and five different ionic strengths were tested. The transfer model based on fractionation of water into mobile and immobile fractions was coupled with the attachment/detachment model to fit NPs breakthrough curves. The results show that increasing flow velocity induces a decrease in nanoparticle retention, probably as the result of several physical but also geochemical factors. The results show that NPs retention increases with ionic strength. However, an inversion of retention occurs for ionic strength >5.10 −2  M, which has been scarcely observed in previous studies. The measure of zeta potential and DLVO calculations show that NPs may sorb on both solid-water and air-water interfaces. NPs size distribution shows the potential for nanoparticle agglomeration mostly at low pH, leading to entrapment in the soil pores. These mechanisms are highly sensitive to both hydrodynamic and geochemical conditions, which explains their high sensitivity to flow rates and ionic strength.

  20. Nanoparticle transport in water-unsaturated porous media: effects of solution ionic strength and flow rate

    Energy Technology Data Exchange (ETDEWEB)

    Prédélus, Dieuseul; Lassabatere, Laurent, E-mail: laurent.lassabatere@entpe.fr [Université de Lyon, Laboratoire d’Ecologie des Hydrosystèmes Naturels et Anthropisés, LEHNA (France); Louis, Cédric; Gehan, Hélène [Nano-H S.A.S., 2 place de l’Europe, Bâtiment A, Parc d’activité VALAD (France); Brichart, Thomas [Université Lyon 1-CNRS, Institut Lumière Matière, UMR 5306 CNRS (France); Winiarski, Thierry; Angulo-Jaramillo, Rafael [Université de Lyon, Laboratoire d’Ecologie des Hydrosystèmes Naturels et Anthropisés, LEHNA (France)

    2017-03-15

    This paper presents the influence of ionic strength and flow on nanoparticle (NP) retention rate in an unsaturated calcareous medium, originating from a heterogeneous glaciofluvial deposit of the region of Lyon (France). Laboratory columns 10 cm in diameter and 30 cm in length were used. Silica nanoparticles (Au-SiO{sub 2}-FluoNPs), with hydrodynamic diameter ranging from 50 to 60 nm and labeled with fluorescein derivatives, were used to simulate particle transport, and bromide was used to characterize flow. Three flow rates and five different ionic strengths were tested. The transfer model based on fractionation of water into mobile and immobile fractions was coupled with the attachment/detachment model to fit NPs breakthrough curves. The results show that increasing flow velocity induces a decrease in nanoparticle retention, probably as the result of several physical but also geochemical factors. The results show that NPs retention increases with ionic strength. However, an inversion of retention occurs for ionic strength >5.10{sup −2} M, which has been scarcely observed in previous studies. The measure of zeta potential and DLVO calculations show that NPs may sorb on both solid-water and air-water interfaces. NPs size distribution shows the potential for nanoparticle agglomeration mostly at low pH, leading to entrapment in the soil pores. These mechanisms are highly sensitive to both hydrodynamic and geochemical conditions, which explains their high sensitivity to flow rates and ionic strength.