WorldWideScience

Sample records for storage phosphor imaging

  1. Intravascular imaging with a storage phosphor detector

    Energy Technology Data Exchange (ETDEWEB)

    Shikhaliev, Polad M; Petrek, Peter; Matthews, Kenneth L II; Fritz, Shannon G [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA (United States); Bujenovic, L Steven [PET Imaging Center, Our Lady of the Lake Medical Center, Baton Rouge, LA (United States); Xu Tong, E-mail: pshikhal@lsu.ed [Department of Physics, Carleton University, Ottawa (Canada)

    2010-05-21

    The aim of this study is to develop and test an intravascular positron imaging system based on a storage phosphor detector for imaging and detecting vulnerable plaques of human coronary arteries. The radiotracer F18-FDG accumulates in vulnerable plaques with inflammation of the overlying cap. The vulnerable plaques can, therefore, be imaged by recording positrons emitted from F18-FDG with a detector inserted into the artery. A prototype intravascular detector was constructed based on storage phosphor. The detector uses a flexible storage phosphor tube with 55 mm length, 2 mm diameter and 0.28 mm wall thickness. The intravascular detector is guided into the vessel using x-ray fluoroscopy and the accumulated x-ray signal must be erased prior to positron imaging. For this purpose, a light diffuser, 0.9 mm in diameter and 55 mm in length, was inserted into the detector tube. The light diffuser was connected to a laser source through a 2 m long optical fiber. The diffuser redirected the 0.38 W laser light to the inner surface of the phosphor detector to erase it. A heart phantom with 300 cm{sup 3} volume and three coronary arteries with 3.2 mm diameter and with several plaques was constructed. FDG solution with 0.5 {mu}Ci cm{sup -3} activity concentration was filled in the heart and coronary arteries. The detector was inserted in a coronary artery and the signal from the plaques and surrounding background activity was recorded for 2 min. Then the phosphor detector was extracted and read out using a storage phosphor reader. The light diffuser erased the signal resulting from fluoroscopic exposure to level below that encountered during positron imaging. Vulnerable plaques with area activities higher than 1.2 nCi mm{sup -2} were visualized by the detector. This activity is a factor of 10-20 lower than that expected in human vulnerable plaques. The detector was able to image the internal surface of the coronary vessels with 50 mm length and 360{sup 0} circumference. Spatial

  2. Transparent caesium bromide storage-phosphors for radiation imaging

    Energy Technology Data Exchange (ETDEWEB)

    Winch, Nicola M. [School of Chemical and Physical Sciences, Victoria University of Wellington, Wellington (New Zealand); Edgar, Andrew [School of Chemical and Physical Sciences, Victoria University of Wellington, Wellington (New Zealand); MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, Wellington (New Zealand)

    2012-12-15

    Semi-transparent discs of polycrystalline CsBr:Eu{sup 2+} storage phosphor for X-ray imaging have been produced using a room temperature milling/pressing technique, and have been studied using infrared, and photoluminescence spectroscopies, together with scanning electron microscopy. The pressed discs are very sensitive to water vapour, and scanning electron microscopy shows that material undergoes a complete recrystallization following exposure to humid air for a few minutes through a room temperature hydration/crystallization process. Discs prepared by a simple mixture of CsBr and EuBr{sub 2} show photostimulated luminescence (PSL) at 440 nm without further processing, and the conversion efficiency is sufficient that X-ray imaging can be demonstrated. Discs which have been prepared by first sintering at 600 C, then pressed, and finally hydrated at room temperature show very strong PSL with a conversion efficiency of {proportional_to}36 pJ mR{sup -1} mm{sup -3}. A model is proposed for the generation of the active PSL centres in CsBr by the milling/hydration process. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. High-resolution storage phosphor imaging of the chest: Comparison with conventional screen-film systems

    International Nuclear Information System (INIS)

    Fuhrman, C.R.; Good, B.; Feist, J.; Gur, D.; Darby, J.

    1987-01-01

    An experimental high-resolution storage phosphor imaging system (Eastman Kodak) has been used to evaluate the image quality and impact on diagnostic interpretation of storage phosphor images relative to conventional screen-film images of the same patients. The elements of the system include a high-resolution laser scanner (4K X 5K X 12 bit); an image processing system; and a high-resolution (4K X 5K X 12 bit) laser printer. Each case was digitally printed onto film in two different formats: a full-size (14 X 14-inch) and a half-size format of four processed, minified images (7 X 7-inches each). The multiformat image includes an original, an unsharp-masked, a reversed (black bone) unsharp-masked, and a high-contrast unsharp-masked image. The results of this preliminary study (11 cases, eight readers) clearly indicate that after minimal adjustment, radiologists do not object to making diagnoses from minified images. Unsharp masked images were considered preferable to unprocessed images, and processed storage phosphor images were rated significantly better than conventional film images

  4. Two K versus 4 K storage phosphor chest radiography: detection performance and image quality

    NARCIS (Netherlands)

    Koelblinger, Claus; Prokop, Mathias; Weber, Michael; Sailer, Johannes; Cartes-Zumelzu, Fabiola; Schaefer-Prokop, Cornelia

    2007-01-01

    The purpose of this study was to evaluate the effect of matrix size (4-K versus 2-K) in digital storage phosphor chest radiographs on image quality and on the detection of CT-proven thoracic abnormalities. In 85 patients who underwent a CT of the thorax, we obtained two additional posteroanterior

  5. Digital imaging using storage phosphor screens a film-less procedure to detect radiation

    International Nuclear Information System (INIS)

    Narayana Rao, A.V.S.S.; Mahajan, S.K.

    1998-01-01

    The imaging plate is a film-like radiation sensor comprising of specifically designed phosphors (photostimulable storage phosphors) that trap and store energy resulting from the decay of radioactive atoms in the sample. In a typical setup, samples containing radioactivity are placed next to the imaging plate for a duration of about 5-10 times less than that is needed for normal x-ray films. The stored energy is stable until scanned with a laser beam, which releases the energy as luminescence. Digital signal processing of the emitted light results in an image which represents a quantitative measure of the activity of the radiolabeled sample. This phosphor technology, launched in its first application to the medical x-ray diagnostic field, portends great promise in a wide range of newer scientific and technological applications. (author)

  6. Storage phosphor radiography of wrist fractures: a subjective comparison of image quality at varying exposure levels

    Energy Technology Data Exchange (ETDEWEB)

    Peer, Regina; Giacomuzzi, Salvatore M.; Bodner, Gerd; Jaschke, Werner; Peer, Siegfried [Innsbruck Univ. (Austria). Inst. fuer Radiologie; Lanser, Anton [Academy of Radiology Technicians, Innsbruck (Austria); Pechlaner, Sigurd [Department of Traumatology, University Hospital, Innsbruck (Austria); Kuenzel, Karl Heinz; Gaber, O. [Department of Anatomy and Histology, University Hospital, Innsbruck (Austria)

    2002-06-01

    Image quality of storage phosphor radiographs acquired at different exposure levels was compared to define the minimal radiation dose needed to achieve images which allow for reliable detection of wrist fractures. In a study on 33 fractured anatomical wrist specimens image quality of storage phosphor radiographs was assessed on a diagnostic PACS workstation by three observers. Images were acquired at exposure levels corresponding to a speed classes 100, 200, 400 and 800. Cortical bone surface, trabecular bone, soft tissues and fracture delineation were judged on a subjective basis. Image quality was rated according to a standard protocol and statistical evaluation was performed based on an analysis of variance (ANOVA). Images at a dose reduction of 37% were rated sufficient quality without loss in diagnostic accuracy. Sufficient trabecular and cortical bone presentation was still achieved at a dose reduction of 62%. The latter images, however, were considered unacceptable for fracture detection. To achieve high-quality storage phosphor radiographs, which allow for a reliable evaluation of wrist fractures, a minimum exposure dose equivalent to a speed class of 200 is needed. For general-purpose skeletal radiography, however, a dose reduction of up to 62% can be achieved. A choice of exposure settings according to the clinical situation (ALARA principle) is recommended to achieve possible dose reductions. (orig.)

  7. Two K versus 4 K storage phosphor chest radiography: detection performance and image quality

    International Nuclear Information System (INIS)

    Koelblinger, Claus; Weber, Michael; Sailer, Johannes; Cartes-Zumelzu, Fabiola; Prokop, Mathias; Schaefer-Prokop, Cornelia

    2007-01-01

    The purpose of this study was to evaluate the effect of matrix size (4-K versus 2-K) in digital storage phosphor chest radiographs on image quality and on the detection of CT-proven thoracic abnormalities. In 85 patients who underwent a CT of the thorax, we obtained two additional posteroanterior storage phosphor chest radiographs, one with a matrix size of 3,520 x 4,280 (=4-K) and the other with a matrix size of 1,760 x 2,140 (=2-K). Acquisition, processing and presentation parameters were identical for all radiographs. Two radiologists evaluated the presence of mediastinal, pleural, and pulmonary abnormalities on hard copies of the radiographs, applying ROC analysis. In addition, four radiologists were asked to subjectively rank differences in image quality and to assess the demarcation of anatomic landmarks comparing the images in a blinded side-by-side manner. These data were analyzed using a two-sided binomial test with a significance level of P<0.05. Both tests, the ROC analysis of the detection performance and the binomial test of the subjective quality ratings, did not reveal significant differences between the two matrix sizes. Compared to 2-K radiographs, 4-K storage phosphor chest radiographs do not provide superior detection performance or image quality when evaluated in identical hard copy formats. (orig.)

  8. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  9. Digital chest radiography with an amorphous silicon flat-panel-detector versus a storage-phosphor system: comparison of soft-copy images

    International Nuclear Information System (INIS)

    Lee, Hyun Ju; Im, Jung Gi; Goo, Jin Mo; Lee, Chang Hyun

    2006-01-01

    We compared the soft-copy images produced by an amorphous silicon flat-panel-detector system with the images produced by a storage-phosphor radiography system for their ability to visualize anatomic regions of the chest. Two chest radiologists independently analyzed 234 posteroanterior chest radiographs obtained from 78 patients on high-resolution liquid crystal display monitors (2560 x 2048 x 8 bits). In each patient, one radiograph was obtained with a storage-phosphor system, and two radiographs were obtained via amorphous silicon flat-panel-detector radiography with and without spatial frequency filtering. After randomizing the 234 images, the interpreters rated the visibility and radiographic quality of 11 different anatomic regions. Each image was ranked on a five-point scale (1 = not visualized, 2 = poor visualization, 3 = fair visualization, 4 = good visualization, and 5 = excellent visualization). The statistical difference between each system was determined using the Wilcoxon's signed rank test. The visibility of three anatomic regions (hilum, heart border and ribs), as determined by the chest radiologist with 14 years experience (ρ < 0.05) and the visibility of the thoracic spine, as determined by the chest radiologist with 8 years experience (ρ = 0.036), on the amorphous silicon flat-panel-detector radiography prior to spatial frequency filtering were significantly superior to that on the storage-phosphor radiography. The visibility of 11 anatomic regions, as determined by the chest radiologist with 14 years experience (ρ < 0.0001) and the visibility of five anatomic regions (unobscured lung, rib, proximal airway, thoracic spine and overall appearance), as determined by the chest radiologist with 8 years experience (ρ < 0.05), on the amorphous silicon flat-panel-detector radiography after spatial frequency filtering were significantly superior to that on the storage-phosphor radiography. The amorphous silicon flat-panel-detector system depicted the

  10. Radioactivity measurements using storage phosphor technology

    International Nuclear Information System (INIS)

    Cheng, Y.T.; Hwang, J.; Hutchinson, M.R.

    1995-01-01

    We propose to apply a recently developed charged particle radiation imaging concept in bio-medical research for fast, cost-effective characterization of radionuclides in contaminated sites and environmental samples. This concept utilizes sensors with storage photostimulable phosphor (SPP) technology as radiation detectors. They exhibit high sensitivity for all types of radiation and the response is linear over a wide dynamic range (>10 5 ), essential for quantitative analysis. These new sensors have an active area of up to 35 cm x 43 cm in size and a spatial resolution as fine as 50 μm. They offer considerable promise as large area detectors for fast characterization of radionuclides with an added ability to locate and identify hot spots

  11. Experimental investigations of image quality in X-ray mammography with conventional screen film system (SFS), digital phosphor storage plate in/without magnification technique (CR) and digital CCD-technique (CCD)

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Wenkel, E.; Bautz, W.; Saebel, M.

    2001-01-01

    Comparison of image quality in X-ray mammography between conventional film screen film system (SFS), digital phosphor storage plate in and without magnification technique (CR) and digital CCD-technique (CCD). Radiograms of an RMI-mammography phantom were acquired using a conventional screen film system, three digital storage plate systems and two digital systems in CCD-technique. Additionally the radiograms of one digital phosphor storage plate system were post-processed regarding contrast and included in the comparison. The detectability of details was best with the digital mammography in CCD-technique. After confirming these promising results in clinical studies, digital mammography should be able to replace conventional screen film technique. (orig.)

  12. Improvements in x-ray image converters and phosphors

    International Nuclear Information System (INIS)

    Rabatin, J.G.

    1981-01-01

    Improvements to an X-ray image converter comprising crystals of rare earth phosphor admixtures are described. The phosphor admixtures utilize thulium-activated lanthanum and/or gadolinium oxyhalide phosphor material to increase the relative speed and resolution of an X-ray image compared with conventional rare earth phosphors. Examples of various radiographic screens containing one or more of the phosphor materials are given. (U.K.)

  13. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    Energy Technology Data Exchange (ETDEWEB)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-04-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  14. Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures

    International Nuclear Information System (INIS)

    Peer, Siegfried; Neitzel, Ulrich; Giacomuzzi, Salvatore M.; Pechlaner, Sigurd; KUenzel, Karl Heinz; Peer, Regina; Gassner, Eva; Steingruber, Iris; Gaber, O.; Jaschke, Werner

    2002-01-01

    AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the performance of caesium iodide/amorphous silicon flat panel detector exceeds state of the art storage phosphor radiography. This makes it well suited for skeletal imaging particularly in trauma as seen in the detection of wrist fractures. Peer, S. et al. (2002)

  15. Phosphor Scanner For Imaging X-Ray Diffraction

    Science.gov (United States)

    Carter, Daniel C.; Hecht, Diana L.; Witherow, William K.

    1992-01-01

    Improved optoelectronic scanning apparatus generates digitized image of x-ray image recorded in phosphor. Scanning fiber-optic probe supplies laser light stimulating luminescence in areas of phosphor exposed to x rays. Luminescence passes through probe and fiber to integrating sphere and photomultiplier. Sensitivity and resolution exceed previously available scanners. Intended for use in x-ray crystallography, medical radiography, and molecular biology.

  16. Assessment of clinical image quality in feline chest radiography with a needle-image plate (NIP) storage phosphor system. An approach to the evaluation of image quality in neonatal radiography; Untersuchungen zur Qualitaet von Thoraxaufnahmen bei Katzen mit einem auf einer Nadelstruktur basierenden Speicherfoliensystem. Modelluntersuchungen zur Bewertung der Bildqualitaet bei Neugeborenen

    Energy Technology Data Exchange (ETDEWEB)

    Ludewig, E.; Bosch, B.; Gaebler, K.; Succow, D.; Werrmann, A. [Klinik fuer Kleintiere, Univ. Leipzig (Germany); Hirsch, W.; Sorge, I. [Abt. Paediatrische Radiologie, Univ. Leipzig (Germany); Gosch, D. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Univ. Leipzig (Germany)

    2010-02-15

    Purpose: Is the image quality of thoracic radiographs of cats obtained with a needle-based storage phosphor (NIP) system superior to conventional (PIP) storage phosphor radiography? Is it possible to decrease the mAs by 50% with the NIP system without significant loss of information? Materials and Methods: From each of the 20 animals, three lateral radiographs were acquired. The assessment of the exposure level was based on the generated IgM-values. Images were acquired 1. with the NIP system and exposure settings equivalent to an IgM of 1.9, 2. with the PIP system and identical settings, and 3. with the NIP system and 50% of the mAs. Six blinded readers used a 5-step scale to assess the reproducibility of five anatomical structures and image noise sensation. Data were analysed using Visual Grading Characteristics Analysis (VGC). Results: While applying identical exposure values the NIP system for all features revealed superior ratings to those of the PIP system (AUC{sub VGC} values ranged from 0.81 for ''cardiac silhouette'' to 0.92 for ''trachea''). Even when reducing mAs by 50% in the NIP images all features were rated better compared with the PIP images and original settings (AUC{sub VGC} values ranged from 0.60 for ''cardiac silhouette'' to 0.74 for ''trachea'' and ''caudal thoracic field''). Conclusion: The NIP system demonstrates clearly better image quality compared to the reference PIP system. A dose reduction of 50% seems to be possible without relevant detraction from image quality. The results obtained in the animal model are valid for simulating conditions in neonatal radiological practise. (orig.)

  17. Phosphors

    International Nuclear Information System (INIS)

    1975-01-01

    This invention relates to phosphors that can be used in fluorescent lamps and display devices. The phosphor is comprised of a halophosphate of calcium and/or strontium of apatite crystal structure activated with trivalent cerium and trivalent terbium. The phosphor can further include manganese. Preferably, the phosphor includes up to 10% by weight of one or more of the alkali metals lithium, sodium and potassium in the form of a compound or compounds thereof. The emissions appear as a number of fairly narrow discrete bands. The temperature of preparation is 1000degC (as opposed to the usual 1450degC), therefore reducing costs (less energy is needed, more crucibles are readily obtainable and there is no need for special conditions to enable crucibles to overcome thermal shock)

  18. Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Kitahama, Hiroyuki

    1991-01-01

    The aim of this study is to present efficacy of storage phosphor-based digital mammography (CR-mammography) in diagnosis of breast cancer. Ninety-seven cases with breast cancer including 44 cases less than 2 cm in macroscopic size (t1 cases) were evaluated using storage phosphor-based digital mammography (2000 x 2510 pixels by 10 bits). Abnormal findings on CR-mammography were detected in 86 cases (88.7%) of 97 women with breast cancer. Sensitivity of CR-mammography was 88.7%. It was superior to that of film-screen mammography. On t1 breast cancer cases, sensitivity on CR-mammography was 88.6%. False negative rate in t1 breast cancer cases was reduced by image processing using CR-mammography. To evaluate microcalcifications, CR-mammograms and film-screen mammograms were investigated in 22 cases of breast cancer proven pathologically the existence of microcalcifications and 11 paraffin tissue blocks of breast cancer. CR-mammography was superior to film-screen mammography in recognizing of microcalcifications. As regards the detectability for the number and the shape of microcalcifications, CR-mammography was equivalent to film-screen mammography. Receiver operating characteristic (ROC) analysis by eight observers was performed for CR-mammography and film-screen mammography with 54 breast cancer patients and 54 normal cases. The detectability of abnormal findings of breast cancer on CR-mammography (ROC area=0.91) was better than that on film-screen mammography (ROC area=0.88) (p<0.05). Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer was discussed and demonstrated in this study. (author)

  19. Portal verification using the KODAK ACR 2000 RT storage phosphor plate system and EC films. A semiquantitative comparison.

    Science.gov (United States)

    Geyer, Peter; Blank, Hilbert; Alheit, Horst

    2006-03-01

    The suitability of the storage phosphor plate system ACR 2000 RT (Eastman Kodak Corp., Rochester, MN, USA), that is destined for portal verification as well as for portal simulation imaging in radiotherapy, had to be proven by the comparison with a highly sensitive verification film. The comparison included portal verification images of different regions (head and neck, thorax, abdomen, and pelvis) irradiated with 6- and 15-MV photons and electrons. Each portal verification image was done at the storage screen and the EC film as well, using the EC-L cassettes (both: Eastman Kodak Corp., Rochester, MN, USA) for both systems. The soft-tissue and bony contrast and the brightness were evaluated and compared in a ranking of the two compared images. Different phantoms were irradiated to investigate the high- and low-contrast resolution. To account for quality assurance application, the short-time exposure of the unpacked and irradiated storage screen by green and red room lasers was also investigated. In general, the quality of the processed ACR images was slightly higher than that of the films, mostly due to cases of an insufficient exposure to the film. The storage screen was able to verify electron portals even for low electron energies with only minor photon contamination. The laser lines were sharply and clearly visible on the ACR images. The ACR system may replace the film without any noticeable decrease in image quality thereby reducing processing time and saving the costs of films and avoiding incorrect exposures.

  20. A SrBPO5: Eu2+ phosphor for neutron imaging

    International Nuclear Information System (INIS)

    Sakasai, K.; Katagiri, M.; Toh, K.; Nakamura, T.

    2001-01-01

    A SrBPO 5 : Eu 2+ phosphor material has been investigated for neutron imaging. This phosphor showed photostimulated luminescence (PSL) by illumination of 635 nm laser light after X-ray irradiation. The spectral characteristics of the phosphor were similar to those of BaFBr: Eu 2+ , which is a commonly used phosphor of imaging plates. In addition, we found that this phosphor also showed PSL for neutron irradiation. It comes from the fact that it contains atomic boron in base matrix. Therefore, this phosphor can be used for neutron imaging without adding neutron sensitive materials such as Gd in commercially available neutron imaging plates. The PSL intensity and the neutron detection will be increased by using enriched boron instead of natural boron. (author)

  1. Portal verification using the KODAK ACR 2000 RT storage phosphor plate system and EC registered films. A semiquantitative comparison

    International Nuclear Information System (INIS)

    Geyer, P.; Blank, H.; Alheit, H.

    2006-01-01

    Background and Purpose: the suitability of the storage phosphor plate system ACR 2000 RT (Eastman Kodak Corp., Rochester, MN, USA), that is destined for portal verification as well as for portal simulation imaging in radiotherapy, had to be proven by the comparison with a highly sensitive verification film. Material and Methods: the comparison included portal verification images of different regions (head and neck, thorax, abdomen, and pelvis) irradiated with 6- and 15-MV photons and electrons. Each portal verification image was done at the storage screen and the EC registered film as well, using the EC-L registered cassettes (both: Eastman Kodak Corp., Rochester, MN, USA) for both systems. The soft-tissue and bony contrast and the brightness were evaluated and compared in a ranking of the two compared images. Different phantoms were irradiated to investigate the high- and low-contrast resolution. To account for quality assurance application, the short-time exposure of the unpacked and irradiated storage screen by green and red room lasers was also investigated. Results: in general, the quality of the processed ACR images was slightly higher than that of the films, mostly due to cases of an insufficient exposure to the film. The storage screen was able to verify electron portals even for low electron energies with only minor photon contamination. The laser lines were sharply and clearly visible on the ACR images. Conclusion: the ACR system may replace the film without any noticeable decrease in image quality thereby reducing processing time and saving the costs of films and avoiding incorrect exposures. (orig.)

  2. WE-AB-BRB-01: Memorial Introduction; Storage Phosphor Panels for Radiation Therapy Dosimetry

    International Nuclear Information System (INIS)

    Li, H.

    2016-01-01

    Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558

  3. WE-AB-BRB-01: Memorial Introduction; Storage Phosphor Panels for Radiation Therapy Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Li, H. [Washington University School of Medicine (United States)

    2016-06-15

    Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558

  4. Effects of scanning resolution and digital image magnification on photostimulable phosphor imaging system

    International Nuclear Information System (INIS)

    Sakurai, Takashi; Inagaki, Masafumi; Asai, Hideomi; Koyama, Atsushi; Kashima, Isamu

    2000-01-01

    The purpose of this study is to examine the effects of changes in scanning resolution and digital magnification on the image quality and diagnostic ability of the photostimulable phosphor imaging system. Using a photostimulable phosphor imaging system, images of a human adult dried mandible phantom embedded in a 25 mm-thick epoxy resin block were made. The latent images on the photostimulable phosphor imaging plate were scanned using four different pixel sizes as follows: 25 μm x 25 μm, 50 μm x 50 μm, 100 μm x 100 μm and 200 μm x 200 μm. A primary image was produced for each pixel size. These images were also digitally magnified at powers of 2, 4 and 8 times. The gradient range, brightness and contrast of each image were adjusted to optimum levels on a cathode ray tube display, and hard copies were produced with a writing pixel size of 60 μm x 60 μm. The granularity, sharpness and anatomical diagnostic ability of the images were assessed subjectively by eight dentists. Increasing the scanning resolution tended to generally improve image quality and diagnostic ability. Visual image quality was maintained up to a pixel size of 50 μm, and diagnostic ability was maintained up to a pixel size of 100 μm. Digital image magnification degraded image quality, and more than 2-times magnification degraded diagnostic ability. Under the present experimental conditions, increasing the scanning resolution did not always lead to an improvement in image quality or diagnostic ability, and digital image magnification degraded image quality and diagnostic ability. (author)

  5. Ultraviolet /UV/ sensitive phosphors for silicon imaging detectors

    Science.gov (United States)

    Viehmann, W.; Cowens, M. W.; Butner, C. L.

    1981-01-01

    The fluorescence properties of UV sensitive organic phosphors and the radiometric properties of phosphor coated silicon detectors in the VUV, UV, and visible wavelengths are described. With evaporated films of coronene and liumogen, effective quantum efficiencies of up to 20% have been achieved on silicon photodiodes in the vacuum UV. With thin films of methylmethacrylate (acrylic), which are doped with organic laser dyes and deposited from solution, detector quantum efficiencies of the order of 15% for wavelengths of 120-165 nm and of 40% for wavelengths above 190 nm have been obtained. The phosphor coatings also act as antireflection coatings and thereby enhance the response of coated devices throughout the visible and near IR.

  6. X-ray image converters utilizing rare earth phosphor mixtures

    International Nuclear Information System (INIS)

    Rabatin, J.G.

    1982-01-01

    In an X-ray screen comprising a transparent support with a photographic film on each side, each film has a coating of a phosphor mixture comprising polyhedral Gd 2 O 2 S:Tb of average size 6 to 20 μ and plate-like LnOX:Tm of average size 2 to 12 μ wherein Ln=La or Gd, X=Cl or Br and Tm is present from 0.05 to 1 mole %. The mixture gives improved resolution and reduces the problem of light crossing over the transparent support. According to whether blue sensitive or green sensitive film is used, the ratio of phosphors is varied. U.V. absorbing and light reflecting layers may be incorporated in the structure. (author)

  7. Ultraviolet downconverting phosphor for use with silicon CCD imagers

    Science.gov (United States)

    Blouke, M. M.; Cowens, M. W.; Hall, J. E.; Westphal, J. A.; Christensen, A. B.

    1980-01-01

    The properties and application of a UV downconverting phosphor (coronene) to silicon charge coupled devices are discussed. Measurements of the absorption spectrum have been extended to below 1000 A, and preliminary results indicate the existence of useful response to at least 584 A. The average conversion efficiency of coronene was measured to be approximately 20% at 2537 A. Imagery at 3650 A using a backside illuminated 800 x 800 CCD coated with coronene is presented.

  8. X-ray-sensitive storage phosphors with the optically stable luminescent centres

    CERN Document Server

    Gorin, G B; Zvezdova, N P; Kochubey, D I; Sedova, Y G; Kochubey, D I; Kulipanov, G N; Lyakh, V V; Pindyurin, V F

    2000-01-01

    NaCl, KCl, KBr and LiF crystals doped by In, Tl, Ni, Pd and Ca were investigated as X-ray-sensitive materials. Influence of the way of doping of an impurity and growing of a crystal on such parameters of a material as: sensitivity to ionising radiation; radiative, optical and thermal stability of the image, obtained after an irradiation is investigated. As a result of the work, media for recording of the X-ray images are developed. These allow to reproduce the images in a mode of a photoluminescence. Spatial resolution and the dynamic range of registration of the developed materials concede to similar parameters of commercial storage luminophores like 'Image Plates' based on BaFBr : La. At the same time, as distinct from 'Image Plates', the developed radiophotoluminophores allow a long storage and multiple readout of the information recorded.

  9. Thermoluminescent coactivated rare earth oxyhalide phosphors and x-ray image converters utilizing said phosphors

    International Nuclear Information System (INIS)

    Rabatin, J.G.

    1984-01-01

    Oxyhalides of lanthanum, gadolinium and lutetium coactivated with a first activator selected from bismuth and samarium to provide the color of light emission and a second coactivator (e.g. terbium or praseodymium) which increases the amount of stored energy in a stored radiographic latent image are found to be superior in their conversion efficiency of x-rays to visible light. (author)

  10. Light emission efficiency and imaging properties of YAP:Ce granular phosphor screens

    International Nuclear Information System (INIS)

    Kalivas, N.; Valais, I.; Nikolopoulos, D.; Konstantinidis, A.; Cavouras, D.; Kandarakis, I.; Gaitanis, A.; Nomicos, C.D.; Panayiotakis, G.

    2007-01-01

    Phosphor materials are used in medical imaging combined with radiographic film or other photodetectors. Cerium (Ce 3+ ) -doped scintillators are of particular interest for medical imaging, because of their very fast response. YAP:Ce scintillator-based image detectors have already been evaluated in single-crystal form and under conditions of positron emission tomography and synchrotron or γ-ray irradiation. Furthermore, YAP:Ce phosphor has been evaluated in conjunction with radiographic films. The present work reports experimental and theoretical data concerning the light output absolute luminescence efficiency (AE) of the YAP:Ce screens under irradiation conditions employed in medical X-ray projection imaging (i.e., in diagnostic radiology). projection imaging (i.e., in diagnostic radiology). YAP:Ce phosphor screens with surface densities ranging between 53 and 110 mg/cm 2 were prepared by sedimentation on fused silica substrates in our laboratory. The resulted surface density of the screens was determined by dividing the phosphor mass deposited on the screen surface with the area of the surface. Additionally this work addresses the imaging performance of YAP:Ce by estimation of the detective quantum efficiency (DQE), i.e., the square of the signal to noise ratio transfer. Absolute efficiency was found to decrease with X-ray tube voltage for for YAP:Ce phosphor. The highest experimental efficiency was obtained for the 53.7 mg/cm 2 and 88.0 mg/cm 2 YAP:Ce screens. The highest DQE value was found for the 88.0 mg/cm 2 screen irradiated at 60 kVp. (orig.)

  11. Entropy as a measure of the performance of phosphor materials used in medical imaging radiation detectors

    International Nuclear Information System (INIS)

    Cavouras, D.; Kandarakis, I.; Maris, T.; Panayiotakis, G.S.; Nomicos, C.D.

    2001-01-01

    In information theory, entropy expresses the information gain obtained after detection of a signal concerning the state of a parameter of interest. In this study, entropy has been expressed in terms of physical quantities (emitted optical fluence and MTF) related to the imaging performance of phosphor materials, which are employed in medical imaging radiation detectors. Four phosphor materials, used in the form of laboratory-prepared fluorescent layers (screens), were compared on the basis of their entropy performance. Measurements were performed using 30- and 80-kVp X-ray beams often employed in X-ray imaging. Results showed that phosphor materials with high density and effective atomic number exhibit high entropy performance, especially at the higher X-ray tube voltage of 80 kVp. Entropy values are also affected by the type of activator, which determines the intrinsic X-ray-to-light conversion efficiency, and the spectrum of emitted light. The proximity of the incident X-ray quanta energy to the energy of the K-shell threshold for photoelectric absorption is an additional important factor which increases entropy. This effect was more apparent in the performance of yttrium-based phosphors at the lower voltage of 30 kVp. (orig.)

  12. Lu{sub 2}O{sub 3}:Tb,Hf storage phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Kulesza, Dagmara; Trojan-Piegza, Joanna [Faculty of Chemistry, University of Wroclaw, 14 F. Joliot-Curie Street, 50-383 Wroclaw (Poland); Zych, Eugeniusz, E-mail: zych@wchuwr.p [Faculty of Chemistry, University of Wroclaw, 14 F. Joliot-Curie Street, 50-383 Wroclaw (Poland)

    2010-03-15

    Lu{sub 2}O{sub 3}:Tb,Hf ceramics containing 0.1% of Tb and 0-1.5% of Hf were prepared in reducing atmosphere at 1700 {sup o}C and their thermoluminescence properties were systematically studied. For comparison Tb,Ca co-doped specimen was also fabricated and investigated. The Tb,Hf ceramics shows basically a single TL band located around 180 {sup o}C as found with heating rate of 15 {sup o}C/min. Ceramics singly doped with Tb show complex TL glow curves indicating the presence of traps of very different depths. On the other hand Tb,Ca co-doping is beneficial for the development of shallow traps with the main TL band around 70 {sup o}C. Hence, the aliovalent impurities, Ca{sup 2+} and Hf{sup 4+}, strongly influenced the traps structure in Lu{sub 2}O{sub 3}:Tb ceramics, each of them in its own specific way. Isothermal decay of Lu{sub 2}O{sub 3}:Tb,Hf at 185 {sup o}C was recorded and its shape suggest that multiple hole trapping occurs in the Lu{sub 2}O{sub 3}:Tb,Hf ceramics. Due to the different traps depths the Lu{sub 2}O{sub 3}:Tb,Hf ceramics possess properties typical for storage phosphors, while Lu{sub 2}O{sub 3}:Tb,Ca is a persistent luminescent material rather.

  13. Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates.

    Science.gov (United States)

    Eskandarloo, Amir; Yousefi, Arman; Soheili, Setareh; Ghazikhanloo, Karim; Amini, Payam; Mohammadpoor, Haniyeh

    2017-01-01

    Nowadays, digital radiography is widely used in dental practice. One of the most common types is Photo Stimulated Phosphor Plate (PSP). The aims of this experimental study were to evaluate the impacts of different combinations of storage conditions and varying delays in reading of digital images captured using PSPs. Standardized images of a step wedges were obtained using PSPs from the Digora digital systems. Plates were exposed and immediately scanned to produce the baseline gold standard. The plates were re-exposed and stored in four different storage conditions: white light, yellow light, natural light environment and dark room, then scanned after 10 and 30 minutes and 4 and 8 hours. Objective analysis was conducted by density measurements and the data were analyzed statistically using GEE test. Subjective analysis was performed by two oral and maxillofacial radiologists and the results were analyzed using McNemar's test. The results from GEE analysis show that in the natural light environment, the densities in 10 minutes did not differ from the baseline. The mean densities decreased significantly during the time in all environments. The mean densities in step 2 for the dark room environment decreased with a slighter slope in comparison to yellow environment significantly. PSP images showed significant decrease in the density in plates scanned for 10 minutes or longer after exposure which may not be detected clinically. The yellow light environment had a different impact on the quality of PSP images. The spatial resolution did not change significantly with time.

  14. An in vitro comparison of diagnostic abilities of conventional radiography, storage phosphor, and cone beam computed tomography to determine occlusal and approximal caries

    Energy Technology Data Exchange (ETDEWEB)

    Kayipmaz, Saadettin, E-mail: kayipmaz@ktu.edu.tr [Karadeniz Technical University, Faculty of Dentistry, Department of Oral Diagnosis and Radiology, Farabi, 61080 Trabzon (Turkey); Sezgin, Omer Said, E-mail: omersaidsezgin@gmail.com [Karadeniz Technical University, Faculty of Dentistry, Department of Oral Diagnosis and Radiology, Farabi, 61080 Trabzon (Turkey); Saricaoglu, Senem Tugra, E-mail: senem_tugra@hotmail.com [Karadeniz Technical University, Faculty of Dentistry, Department of Oral Diagnosis and Radiology, Farabi, 61080 Trabzon (Turkey); Can, Gamze, E-mail: gcanktu@yahoo.com [Karadeniz Technical University Faculty of Medicine Department of Public Health (Turkey)

    2011-11-15

    Aim: The aim of this study was to compare conventional radiography, storage phosphor plate, and cone beam computed tomography for in vitro determination of occlusal and approximal caries. Methods: A total of 72 extracted human premolar and molar teeth were selected. Teeth were radiographed with conventional intraoral radiography, a storage phosphor plate system, and cone beam computed tomography and evaluated by two observers. The teeth were then separated and examined with a stereomicroscope and a scanner at approximately 8x magnification. Results: CBCT was statistically superior to conventional radiography and phosphor plate for determining occlusal caries. No significant difference from CBCT, conventional radiography and the phosphor plate system for determining approximal caries was found. Conclusion: The CBCT system may be used as an auxiliary method for the detection of caries.

  15. An in vitro comparison of diagnostic abilities of conventional radiography, storage phosphor, and cone beam computed tomography to determine occlusal and approximal caries

    International Nuclear Information System (INIS)

    Kayipmaz, Saadettin; Sezgin, Omer Said; Saricaoglu, Senem Tugra; Can, Gamze

    2011-01-01

    Aim: The aim of this study was to compare conventional radiography, storage phosphor plate, and cone beam computed tomography for in vitro determination of occlusal and approximal caries. Methods: A total of 72 extracted human premolar and molar teeth were selected. Teeth were radiographed with conventional intraoral radiography, a storage phosphor plate system, and cone beam computed tomography and evaluated by two observers. The teeth were then separated and examined with a stereomicroscope and a scanner at approximately 8x magnification. Results: CBCT was statistically superior to conventional radiography and phosphor plate for determining occlusal caries. No significant difference from CBCT, conventional radiography and the phosphor plate system for determining approximal caries was found. Conclusion: The CBCT system may be used as an auxiliary method for the detection of caries.

  16. Monte Carlo Investigation of Phosphor Screens for X-ray Imaging

    International Nuclear Information System (INIS)

    Lim, Chang Hwy; Cheong, Min Ho; Cho, Min Kook; Shon, Choel Soon; Kim, Ho Kyung

    2006-01-01

    In order to detect X rays with pixel detectors, there are two technical methods; a direct detection using photoconductive material that permits the conversion of the incident X rays into the signal charges, and an indirect detection using scintillation material that converts the incident X rays into the optical photons. Therefore, two-dimensional (2D) photosensitive pixel array is necessary for the indirect-detection scheme. Terbium-doped gadolinium oxysulfide (Gd 2 O 2 S:Tb) phosphor screen is the most popular X-ray converter, and often employed to the digital radiographic system owing to its well-known technology and easy handling in size, thickness, and flexibility. Furthermore, the cost is effective. In cascaded imaging chains of the indirect-detection system, the phosphor screen is served as the first stage. Since the image signal-to-noise ratio (SNR) is irreversible through the cascaded system, the phosphor screen is largely responsible for the eventual image quality. For the various radiation qualities suggested by IEC (International Electrotechnical Commission, Report 1267), we have investigated important physical quantities of Gd 2 O 2 S:Tb screen with a wide range of coverages (34 . 135 mg/cm 2 ) by using Monte Carlo calculations. The results will be useful for the optimal design of digital X-ray imaging systems

  17. Modeling quantum noise of phosphors used in medical X-ray imaging detectors

    CERN Document Server

    Kalivas, N; Cavouras, D; Costaridou, L; Nomicos, C D; Panayiotakis, G S

    1999-01-01

    The noise properties of the granular phosphor screens, which are utilized in X-ray imaging detectors, are studied in terms of the quantum noise transfer function (QNTF). An analytical model, taking into account the effect of K-characteristic X-rays reabsorption within the phosphor material and the optical properties of the phosphor, was developed. The optical properties of the phosphor material required by the model were obtained from literature, except for the optical diffusion length (sigma) that was determined by data fitting and was found to be 26 cm sup 2 /g. The deviation between theoretical and experimental data is sigma depended. Specifically for sigma=26 cm sup 2 /g and sigma=25 cm sup 2 /g the respective deviations between experimental and predicted results were 0.698% and -1.597%. However for relative differences in sigma more than 15% from the value 26 cm sup 2 /g, the corresponding deviations exceed by 6 times the value of 0.698%. The model was tested via comparison to experimental results obtain...

  18. Evaluation of edge enhancement effect of phase contrast imaging using newly-developed photostimulable phosphor plate

    International Nuclear Information System (INIS)

    Matsuo, Satoru; Morishita, Junji; Katafuchi, Tetsuro; Fujita, Hiroshi

    2012-01-01

    We investigated whether the use of a newly developed columnar-crystal-type photostimulable-phosphor plate (CP1M200, referred to as system C) helps to provide improved edge-enhanced effect in phase contrast imaging. Physical characteristics of 2 conventional particulate-crystal-type photostimulable-phosphor plates (RP-5PM, referred to as system A and RP-6M, referred to as system B) and system C were measured. Then, an acrylic plate phantom and RMI152 phantom were imaged using 3 types of plates, and the edge-enhancement effects were evaluated based on the profile curve of the acrylic plate phantom. Visual evaluation of the RMI152 phantom images was conducted. The results showed that the modulation transfer function (MTF) of system C was superior to those of the other systems. The WS of system C was superior to those of the other systems in the low frequency band region, and inferior to those of the other systems in the high frequency band region. The presence of an edge-enhanced image was not detectable in the profile curve of the acrylic plate in system A, although that was shown in systems B and C due to their excellent sharpness. In the visual image evaluation of the RMI152 phantom, image quality of system C was superior to those of the other systems. Phase contrast imaging with a digital detector of a columnar-crystal-type photostimulable-phosphor plate is considered to provide improved edge-enhancement over that of conventional plates. (author)

  19. Geant4 simulation of the response of phosphor screens for X-ray imaging

    International Nuclear Information System (INIS)

    Pistrui-Maximean, S.A.; Freud, N.; Letang, J.M.; Koch, A.; Munier, B.; Walenta, A.H.; Montarou, G.; Babot, D.

    2006-01-01

    In order to predict and optimize the response of phosphor screens, it is important to understand the role played by the different physical processes inside the scintillator layer. A simulation model based on the Monte Carlo code Geant4 was developed to determine the Modulation Transfer Function (MTF) of phosphor screens for energies used in X-ray medical imaging and nondestructive testing applications. The visualization of the dose distribution inside the phosphor layer gives an insight into how the MTF is progressively degraded by X-ray and electron transport. The simulation model allows to study the influence of physical and technological parameters on the detector performances, as well as to design and optimize new detector configurations. Preliminary MTF measurements have been carried out and agreement with experimental data has been found in the case of a commercial screen (Kodak Lanex Fine) at an X-ray tube potential of 100 kV. Further validation with other screens (transparent or granular) at different energies is under way

  20. Geant4 simulation of the response of phosphor screens for X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pistrui-Maximean, S.A. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France)]. E-mail: simona.pistrui@insa-lyon.fr; Freud, N. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France); Letang, J.M. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France); Koch, A. [Thales Electron Devices, 38430 Moirans (France); Munier, B. [Thales Electron Devices, 38430 Moirans (France); Walenta, A.H. [Department of Detectors and Electronics, FB Physik, University of Siegen, 57068 Siegen (Germany); Montarou, G. [Corpuscular Physics Laboratory, Blaise Pascal University, 63177 Aubiere Cedex (France); Babot, D. [Laboratory of Nondestructive Testing using Ionizing Radiation, INSA-Lyon Scientific and Technical University, Bat. Antoine de Saint Exupery, 69621 Villeurbanne Cedex (France)

    2006-07-01

    In order to predict and optimize the response of phosphor screens, it is important to understand the role played by the different physical processes inside the scintillator layer. A simulation model based on the Monte Carlo code Geant4 was developed to determine the Modulation Transfer Function (MTF) of phosphor screens for energies used in X-ray medical imaging and nondestructive testing applications. The visualization of the dose distribution inside the phosphor layer gives an insight into how the MTF is progressively degraded by X-ray and electron transport. The simulation model allows to study the influence of physical and technological parameters on the detector performances, as well as to design and optimize new detector configurations. Preliminary MTF measurements have been carried out and agreement with experimental data has been found in the case of a commercial screen (Kodak Lanex Fine) at an X-ray tube potential of 100 kV. Further validation with other screens (transparent or granular) at different energies is under way.

  1. An imaging system for quantitive surface temperature mapping using two-color thermographic phosphors

    Science.gov (United States)

    Buck, Gregory M.

    1988-01-01

    A technique for obtaining detailed quantitative temperature distributions on test models in hypersonic wind tunnels is presented. This technique is based on the ratio of blue to green (450, 520 nm) emission from an UV (365 nm) excited phosphor coating. Separately filtered images are recorded from a three-tube color camera, utilizing off-the-shelf front-end video optics to discriminate wavelengths. Two demonstration studies in a 31-inch Mach 10 tunnel are discussed. One study presents the windward surface temperature-time history for a transatmospheric vehicle, and the other illustrates nosetip heating on a spherically blunted slender cone.

  2. Evaluation of images in a DR system (KD-1000) with new photostimulable phosphors

    International Nuclear Information System (INIS)

    Yoshita, Hisashi; Kuranishi, Makoto; Nakamura, Mamoru; Kato, Syosuke; Matsui, Mitate.

    1994-01-01

    The Konica Direct Digitizer KD-1000 is a compact chest acquisition unit in digital radiography. The KD-1000 system uses a photostimulable phosphor detector (RbBr: Tl) and directly converts X-ray quantum into digitized information. We have studied the physical characteristics of the KD-1000, which consists of input-output relationship, spatial resolution and noise. Additionally, we have made a comparison of visual detectability between images from the KD-1000 system and those from a film/screen system (KO-380/HRL), which is used for chest radiography. We have quantified these basic characteristics and established the advantage of the KD-1000 system. (author)

  3. Evaluation of images in a DR system (KD-1000) with new photostimulable phosphors

    Energy Technology Data Exchange (ETDEWEB)

    Yoshita, Hisashi; Kuranishi, Makoto; Nakamura, Mamoru; Kato, Syosuke (Toyama Medical and Pharmaceutical Univ. (Japan). Hospital); Matsui, Mitate

    1994-01-01

    The Konica Direct Digitizer KD-1000 is a compact chest acquisition unit in digital radiography. The KD-1000 system uses a photostimulable phosphor detector (RbBr: Tl) and directly converts X-ray quantum into digitized information. We have studied the physical characteristics of the KD-1000, which consists of input-output relationship, spatial resolution and noise. Additionally, we have made a comparison of visual detectability between images from the KD-1000 system and those from a film/screen system (KO-380/HRL), which is used for chest radiography. We have quantified these basic characteristics and established the advantage of the KD-1000 system. (author).

  4. Measurement of activity distribution using photostimulable phosphor imaging plates in decommissioned 10 MV medical linear accelerator.

    Science.gov (United States)

    Fujibuchi, Toshioh; Yonai, Shunsuke; Yoshida, Masahiro; Sakae, Takeji; Watanabe, Hiroshi; Abe, Yoshihisa; Itami, Jun

    2014-08-01

    Photonuclear reactions generate neutrons in the head of the linear accelerator. Therefore, some parts of the linear accelerator can become activated. Such activated materials must be handled as radioactive waste. The authors attempted to investigate the distribution of induced radioactivity using photostimulable phosphor imaging plates. Autoradiographs were produced from some parts of the linear accelerator (the target, upper jaw, multileaf collimator and shielding). The levels of induced radioactivity were confirmed to be non-uniform within each part from the autoradiographs. The method was a simple and highly sensitive approach to evaluating the relative degree of activation of the linear accelerators, so that appropriate materials management procedures can be carried out.

  5. Image quality and radiation exposure in digital storage plate mammography with magnification technique

    International Nuclear Information System (INIS)

    Fiedler, E.; Aichinger, U.; Boehner, C.; Schulz-Wendtland, R.; Bautz, W.; Saebel, M.

    1999-01-01

    Purpose: Comparison of image quality between digital phosphor storage plate mammography in magnification technique and a conventional film screen system regarding the special aspect of radiation exposure. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system and two digital storage plate systems. Additionally, the radiograms of one digital system were postprocessed emphasizing contrast and included in the comparison. Results: The detectability of details in storage plate mammographies with magnification technique is almost equal to that of film screen mammographies. Thereby, lower radiation exposures were necessary using the digital systems. Conclusions: Based on these results, storage plate mammography in magnification technique is used in clinical routine at our institution. The correct parameters in image postprocessing are of elementary importance for detail detectability. Future studies must show, whether the lower radiation exposure in digital radiograms of the breast, revealing much higher background noise, will allow the same detail detectability as film screen mammographies. (orig.) [de

  6. Photoluminescence and photostimulated luminescence in the X-ray storage phosphor BaBr2 doped with cerium

    International Nuclear Information System (INIS)

    Corradi, G.; Secu, M.; Schweizer, S.; Spaeth, J.-M.

    2004-01-01

    In orthorhombic BaBr 2 : Ce 3+ two kinds of luminescence bands at room temperature have been attributed to charge-compensated Ce 3+ centres. One type was associated with potassium (or some other monovalent cation) on a neighbouring Ba site and another one associated with an unidentified defect. A third kind of emission, observed only as low temperature photoluminescence (PL), is ascribed to isolated Ce 3+ ions. The charge-compensated Ce 3+ complexes are active both in PL and photostimulated luminescence (PSL) following X-ray irradiation. The PSL is nearly as efficient as in the case of the commercially used X-ray storage phosphor BaFBr:Eu 2+ . The X-ray induced electrons are trapped in F-type centres whose band position is characteristic for the nearby Ce complex. As shown by the fingerprint character of the PSL itself, the hole partner in the recombination is also associated or identical with the same Ce complex

  7. Medical images storage using discrete cosine transform

    International Nuclear Information System (INIS)

    Arhouma, Ali M.; Ajaal, Tawfik; Marghani, Khaled

    2010-01-01

    The advances in technology during the last decades have made the use of digital images as one of the common things in everyday life. While the application of digital images in communicating information is very important, the cost of storing and transmitting images is much larger compared to storage and transmission of text. The main problem with all of the images was the fact that they take large size of memory space, large transmission bandwidth and long transmission time. Image data compression is needed to reduce the storage space,transmission bandwidth and transmission time. Medical image compression plays a key role as hospitals move towards filmless imaging and go completely digital. Image compression allows Picture Archiving and Communication Systems (PACS) to reduce the file size on their storage requirements while maintaining relevant diagnostic information. The reduced image file size yield reduced transmission times. Even as the capacity of storage media continues to increase, it is expected that the volume of uncompressed data produced by hospitals will exceed capacity of storage and drive up costs. This paper proposes a Discrete Cosine Transform (DCT) algorithm which can help to solve the image storage and transmission time problem in hospitals. Discrete cosine transform (DCT) has become the most popular technique for image compression over the past several years. One of the major reasons for its popularity is its selection as the standard for JPEG. DCTs are most commonly used for non-analytical applications such as image processing and digital signal-processing (DSP) applications such as video conferencing, fax systems, video disks, and high-definition television HDTV. They also can be used on a matrix of practically any dimension. The proposed (DCT) algorithm improves the performance of medical image compression while satisfying both the medical image quality, and the high compression ratio. Application of DCT coding algorithm to actual still images

  8. Investigation of storage-phosphor autoradiography for the rapid quantitative screening of air filters for emergency response purposes

    Science.gov (United States)

    Gallardo, Athena Marie

    Past nuclear accidents, such as Chernobyl, resulted in a large release of radionuclides into the atmosphere. Radiological assessment of the vicinity of the site of the incident is vital to assess the exposure levels and dose received by the population and workers. Therefore, it is critical to thoroughly understand the situation and risks associated with a particular event in a timely manner in order to properly manage the event. Current atmospheric radiological assessments of alpha emitting radioisotopes include acquiring large quantities of air samples, chemical separation of radionuclides, sample mounting, counting through alpha spectrometry, and analysis of the data. The existing methodology is effective, but time consuming and labor intensive. Autoradiography, and the properties of phosphor imaging films, may be used as an additional technique to facilitate and expedite the alpha analysis process in these types of situations. Although autoradiography is not as sensitive to alpha radiation as alpha spectrometry, autoradiography may benefit alpha analysis by providing information about the activity as well as the spatial distribution of radioactivity in the sample under investigation. The objective for this research was to develop an efficient method for quantification and visualization of air filter samples taken in the aftermath of a nuclear emergency through autoradiography using 241Am and 239Pu tracers. Samples containing varying activities of either 241Am or 239Pu tracers were produced through microprecipitation and assayed by alpha spectroscopy. The samples were subsequently imaged and an activity calibration curve was produced by comparing the digital light units recorded from the image to the known activity of the source. The usefulness of different phosphor screens was examined by exposing each type of film to the same standard nuclide for varying quantities of time. Unknown activity samples created through microprecipiation containing activities of

  9. Effect of grinding on photostimuable phosphors for x-ray screens

    International Nuclear Information System (INIS)

    Rao, R.B.

    1988-01-01

    Luminescence efficiency of a phosphor can be improved by minimizing the energy losses during excitation. The loss of excitation energy in the case of powdered samples is mainly due to scattering of incident radiation by the particles of phosphor. Thus, while considering the industrial applications of polycrystalline phosphors in lamps, screens, paints, etc., the effect of particle size on the light output has to be specially studied. It is very well established that the radiographic imaging with photostimuable (PS) phosphors has many advantages over conventional photographic film screens. In the new type of computer radiography, PS phosphors are to be used as memory materials for temporary storage of the x-ray image. Eu(2+) doped barium fluorohalide phosphors are most suitable for this purpose. The spatial resolution from the image plate can be improved to a certain extent with phosphors comprising fine particles. The fineness of the particles can be achieved by various means such as grinding, fast cooling after firing or incorporation of some flux materials during the firing processes. But the efficiency of the phosphor deteriorates with grinding. Fast cooling is a complicated process in the case of Eu(2+) doped phosphors. Incorporation of flux materials may change the characteristics of phosphor materials. In the present investigation, effect of grinding (ball milling) on particle size distribution, shape of the particles and luminescent properties of BaFCl phosphors have been studied

  10. Lu2O3-based storage phosphors. An (in)harmonious family

    NARCIS (Netherlands)

    Kulesza, Dagmara; Bolek, Paulina; Bos, A.J.J.; Zych, E

    2016-01-01

    Ceramics of Lu2O3 activated with either Tb3+ or Pr3+ and co-doped with one of the transition metal ions – Ti, Hf or Nb – were investigated for their energy storage properties. Photoluminescence, thermoluminescence (TL) and optically stimulated luminescence spectra were recorded and discussed

  11. Effect of intrinsic-gain fluctuations on quantum noise of phosphor materials used in medical X-ray imaging

    International Nuclear Information System (INIS)

    Kalivas, N.; Costaridou, L.; Panayiotakis, G.; Nomicos, C.D.

    1999-01-01

    The quality of a medical image depends, among other parameters, on quantum noise. Quantum noise is affected by the fluctuations in the number of optical quanta produced within the phosphor, per absorbed X-ray (i.e. phosphor intrinsic-gain fluctuations). This effect is considered by means of a factor, called in this study intrinsic-gain noise factor, IGNF(E). In existing theoretical models of quantum noise, the corresponding factor is taken to be equal to one. In this paper, an expression that accounts for the coefficient of variation of the phosphor intrinsic gain is introduced. This expression takes into account the process of electron-hole pair conversion to optical photons and the frequency distribution function of the emitted optical photon energy. Subsequently IGNF(E) is expressed in terms of this coefficient of variation. IGNF(E) has been calculated for several phosphors and for various energies. For all medical X-ray energies studied, phosphors that exhibit a high relative fluctuation of emitted optical photon energy, IGNF(E) exceeds by 2% to over 17% the corresponding factor of the existing theoretical models of quantum noise. (orig.)

  12. Subtle pulmonary nodules: detection and identification with storage phosphor radiographs and conventional chest films

    International Nuclear Information System (INIS)

    Scheck, R.J.; Schaetzl, M.; Kandziora, C.; Panzer, M.; Rienmueller, R.

    1994-01-01

    To determine the value of digital storagephosphor radiography (SR) on the detection and identification of subtle lung nodules, postero-anterior (PA) and lateral (LAT) film-screen (FR) chest radiographs were compared with isodose SR images of 45 patients with metastatic malignancies. The SR postprocessing was done with a particular mode previously optimized for routine chest radiography. Pulmonary metastases were found in 34 patients and were proved or excluded by CT (n=28) or longterm follow-up FR (n=17). Chest images were divided into four regions for evaluation of image quality, number of lung nodules per region and marked pulmonary structures by receiver-operating characteristics (ROC) analysis (45 patients; 125 nodules; 2810 observations; five readers). Of the nodules selected for an ROC study 82% were 0.5-1.0 cm in diameter. Overall image quality was rated better for FR concerning lung fields (PA) and mediastinum/hilum (LAT). More lung-field nodules were detected on FR than on SR chest images. Use of FR was superior to SR in the general identification of nodules (PA chest), especially concerning intermediate and subtle abnormalities, whereas there was no significant difference for LAT chest images. Our results show, that currently FR still has advantages over SR in the detection and identification of subtle lung nodules in routine clinical radiography. (orig.)

  13. Development of some phosphors of high quantic efficiency and their application in radiological image reinforcing screens

    International Nuclear Information System (INIS)

    Caticha-Ellis, S.; Alvarez, A.G.; Torrianni, I.L.; Lluesma, E.G.

    1981-01-01

    The establishment of a methodology for the preparation of phosphors and the study of different physical factors which interfere in the process is presented. Emphasis is given on the use of a method of preparation of modern phosphors based on crystalline substracts doped with rare earths. (A.R.H.) [pt

  14. Phantom examination for reduction of radiation dose using new needle screen storage phosphor radiography and add beam filter in digital thoracic radiography on adolescents and larger children

    International Nuclear Information System (INIS)

    Heyne, J.P.; Mentzel, H.J.; Neumann, R.; Lopatta, E.; Zimmermann, U.; Kaiser, W.A.

    2008-01-01

    Purpose: how much can the radiation dose be reduced in thoracic radiography on adolescents and larger children by using needle screen storage phosphor (NIP) radiography and add beam filtration? Materials and methods: a chest phantom with typical anatomical structures, pathological findings, added catheters, and simulated nodules, tumors, and calcifications was X-rayed digitally (DX-S, Agfa Healthcare) in posterior-anterior (p.a.) orientation with and without add beam filter. While keeping the voltage constant, the tube current time product was reduced gradually. In addition to LgM, the surface entrance dose (ED) and the dose area product (DAP) were measured by the Dosimax sensor and Kerma X-plus (both Wellhoefer). Five investigators evaluated the images for characteristics and critical features, pathological findings, and catheter recognizability. Results: the ED of the digital chest radiogram p.a. with 115 kV and 0.71 mAs was 27 μGy, the DAP 3.6 μGy x m 2 , the LgM value 1.56. This initial radiogram was able to be evaluated very well and conforms to the quality guidelines. The dose-reduced chest radiograms with the add beam filter Al 1.0 mm/Cu 0.1 mm were evaluated as sufficiently reduced to a dose of 63% of the initial dose, with the add beam filter Al 1.0 mm/Cu 0.2 mm reduced to 50% (0.52 mAs, DAP 1.82 μGy x m 2 , LgM 1.35). P.a. radiograms were able to be X-rayed on 115 kV with 0.52 mAs. (orig.)

  15. Fast disk array for image storage

    Science.gov (United States)

    Feng, Dan; Zhu, Zhichun; Jin, Hai; Zhang, Jiangling

    1997-01-01

    A fast disk array is designed for the large continuous image storage. It includes a high speed data architecture and the technology of data striping and organization on the disk array. The high speed data path which is constructed by two dual port RAM and some control circuit is configured to transfer data between a host system and a plurality of disk drives. The bandwidth can be more than 100 MB/s if the data path based on PCI (peripheral component interconnect). The organization of data stored on the disk array is similar to RAID 4. Data are striped on a plurality of disk, and each striping unit is equal to a track. I/O instructions are performed in parallel on the disk drives. An independent disk is used to store the parity information in the fast disk array architecture. By placing the parity generation circuit directly on the SCSI (or SCSI 2) bus, the parity information can be generated on the fly. It will affect little on the data writing in parallel on the other disks. The fast disk array architecture designed in the paper can meet the demands of the image storage.

  16. Thermoluminescent phosphor

    Science.gov (United States)

    Lasky, Jerome B.; Moran, Paul R.

    1978-01-01

    A thermoluminescent phosphor comprising LiF doped with boron and magnesium is produced by diffusion of boron into a conventional LiF phosphor doped with magnesium. Where the boron dopant is made to penetrate only the outer layer of the phosphor, it can be used to detect shallowly penetrating radiation such as tritium beta rays in the presence of a background of more penetrating radiation.

  17. Multiplexed image storage by electromagnetically induced transparency in a solid

    Science.gov (United States)

    Heinze, G.; Rentzsch, N.; Halfmann, T.

    2012-11-01

    We report on frequency- and angle-multiplexed image storage by electromagnetically induced transparency (EIT) in a Pr3+:Y2SiO5 crystal. Frequency multiplexing by EIT relies on simultaneous storage of light pulses in atomic coherences, driven in different frequency ensembles of the inhomogeneously broadened solid medium. Angular multiplexing by EIT relies on phase matching of the driving laser beams, which permits simultaneous storage of light pulses propagating under different angles into the crystal. We apply the multiplexing techniques to increase the storage capacity of the EIT-driven optical memory, in particular to implement multiplexed storage of larger two-dimensional amounts of data (images). We demonstrate selective storage and readout of images by frequency-multiplexed EIT and angular-multiplexed EIT, as well as the potential to combine both multiplexing approaches towards further enhanced storage capacities.

  18. Antiproton, positron, and electron imaging with a microchannel plate/phosphor detector

    CERN Document Server

    Andresen, G B; Bowe, P D; Bray, C; Butler, E; Cesar, C L; Chapman, S; Charlton, M; Fajans, J; Fujiwara, M C; Gill, D R; Hangst, J S; Hardy, W N; Hayano, R S; Hayden, M E; Humphries, A J; Hydomako, R; Jørgensen, L V; Kerrigan, S J; Kurchaninov, L; Lambo, R; Madsen, N; Nolan, P; Olchanski, K; Olin, A; Povilus, A; Pusa, P; Sarid, E; Seif El Nasr, S; Silveira, D M; Storey, J W; Thompson, R I; van der Werf, D P; Yamazaki, Y

    2009-01-01

    A microchannel plate (MCP)/phosphor screen assembly has been used to destructively measure the radial profile of cold, confined antiprotons, electrons, and positrons in the ALPHA experiment, with the goal of using these trapped particles for antihydrogen creation and confinement. The response of the MCP to low energy (10-200 eV, <1 eV spread) antiproton extractions is compared to that of electrons and positrons.

  19. Phosphor plate mammography: contrast studies and clinical experience

    International Nuclear Information System (INIS)

    Chang, C.H.J.; Martin, N.L.; Templeton, A.W.; Cook, L.T.; Harrison, L.A.; McFadden, M.A.; Dwyer, S.J. III; Spicer, J.; Crystal, J.M.

    1992-01-01

    Mammography and accurate microcalcification detection require very good spatial resolution. We have compared the diagnostic capabilities of reduced-exposure, third-generation, 5 cycles/mm computed radiography (CR) phosphor plates with conventional screen-film in 67 patients. No difference in diagnostic accuracy was detected. The digital characteristics of storage phosphor plates erabled us to study the relationship between contrast and spatial resolution. We developed a computer program to identify a single 100 μm pixel in a digital image and assign various gray levels to that pixel. Using this model, we determined that, for our 5 cycles/mm CR system, the imaged contrast of a 100 μm object was 62% of the original contrast. Current 5 cycles/mm phosphor plate systems cannot adequately detect microcalcifications that approximate 100 μm or smaller unless a magnification technique is used. (orig.)

  20. Radiation-induced defects and their recombination processes in the x-ray storage phosphor BaBr2:Eu2+

    International Nuclear Information System (INIS)

    Secu, M; Schweizer, S; Rogulis, U; Spaeth, J-M

    2003-01-01

    The recombination processes in the x-ray storage phosphor BaBr 2 :Eu 2+ were investigated by optical and magneto-optical methods. A structure-sensitive investigation of the defects involved in the recombination processes was performed by detecting the microwave-induced changes in the recombination luminescence in a high magnetic field. F centres as well as V K hole centres are created after x-irradiation at low temperatures. The low-energy recombination band peaking at about 460 nm is due to F-V K centre recombinations, whereas the two high energy bands at 282 and 315 nm are probably due to recombinations of self-trapped excitons

  1. Radiation-induced defects and their recombination processes in the x-ray storage phosphor BaBr sub 2 :Eu sup 2 sup +

    CERN Document Server

    Secu, M; Rogulis, U; Spaeth, J M

    2003-01-01

    The recombination processes in the x-ray storage phosphor BaBr sub 2 :Eu sup 2 sup + were investigated by optical and magneto-optical methods. A structure-sensitive investigation of the defects involved in the recombination processes was performed by detecting the microwave-induced changes in the recombination luminescence in a high magnetic field. F centres as well as V sub K hole centres are created after x-irradiation at low temperatures. The low-energy recombination band peaking at about 460 nm is due to F-V sub K centre recombinations, whereas the two high energy bands at 282 and 315 nm are probably due to recombinations of self-trapped excitons.

  2. Image BOSS: a biomedical object storage system

    Science.gov (United States)

    Stacy, Mahlon C.; Augustine, Kurt E.; Robb, Richard A.

    1997-05-01

    Researchers using biomedical images have data management needs which are oriented perpendicular to clinical PACS. The image BOSS system is designed to permit researchers to organize and select images based on research topic, image metadata, and a thumbnail of the image. Image information is captured from existing images in a Unix based filesystem, stored in an object oriented database, and presented to the user in a familiar laboratory notebook metaphor. In addition, the ImageBOSS is designed to provide an extensible infrastructure for future content-based queries directly on the images.

  3. Using Deduplicating Storage for Efficient Disk Image Deployment

    Directory of Open Access Journals (Sweden)

    Xing Lin

    2015-08-01

    Full Text Available Many clouds and network testbeds use disk images to initialize local storage on their compute devices. Large facilities must manage thousands or more images, requiring significant amounts of storage. At the same time, to provide a good user experience, they must be able to deploy those images quickly. Driven by our experience in operating the Emulab site at the University of Utah---a long-lived and heavily-used testbed---we have created a new service for efficiently storing and deploying disk images. This service exploits the redundant data found in similar images, using deduplication to greatly reduce the amount of physical storage required. In addition to space savings, our system is also designed for highly efficient image deployment---it integrates with an existing highly-optimized disk image deployment system, Frisbee, without significantly increasing the time required to distribute and install images. In this paper, we explain the design of our system and discuss the trade-offs we made to strike a balance between efficient storage and fast disk image deployment. We also propose a new chunking algorithm, called AFC, which enables fixed-size chunking for deduplicating allocated disk sectors. Experimental results show that our system reduces storage requirements by up to 3x while imposing only a negligible runtime overhead on the end-to-end disk-deployment process.

  4. Agency Secure Image And Storage Tracking System (ASIST)

    Data.gov (United States)

    US Agency for International Development — Agency Secure Image and Storage Tracking System (Missions): is a Documentum-based user interface developed and maintained by the USAID OCIO (formerly IRM) to improve...

  5. Application of structured illumination to gas phase thermometry using thermographic phosphor particles: a study for averaged imaging

    Science.gov (United States)

    Zentgraf, Florian; Stephan, Michael; Berrocal, Edouard; Albert, Barbara; Böhm, Benjamin; Dreizler, Andreas

    2017-07-01

    Structured laser illumination planar imaging (SLIPI) is combined with gas phase thermometry measurements using thermographic phosphor (TGP) particles. The technique is applied to a heated jet surrounded by a coflow which is operated at ambient temperature. The respective air flows are seeded with a powder of BaMgAl10O17:Eu2+ (BAM) which is used as temperature-sensitive gas phase tracer. Upon pulsed excitation in the ultraviolet spectral range, the temperature is extracted based on the two-color ratio method combined with SLIPI. The main advantage of applying the SLIPI approach to phosphor thermometry is the reduction of particle-to-particle multiple light scattering and diffuse wall reflections, yielding a more robust calibration procedure as well as improving the measurement accuracy, precision, and sensitivity. For demonstration, this paper focuses on sample-averaged measurements of temperature fields in a jet-in-coflow configuration. Using the conventional approach, which in contrast to SLIPI is based on imaging with an unmodulated laser light sheet, we show that for the present setup typically 40% of the recorded signal is affected by the contribution of multiply scattered photons. At locations close to walls even up to 75% of the apparent signal is due to diffuse reflection and wall luminescence of BAM sticking at the surface. Those contributions lead to erroneous temperature fields. Using SLIPI, an unbiased two-color ratio field is recovered allowing for two-dimensional mean temperature reconstructions which exhibit a more realistic physical behavior. This is in contrast to results deduced by the conventional approach. Furthermore, using the SLIPI approach it is shown that the temperature sensitivity is enhanced by a factor of up to 2 at 270 °C. Finally, an outlook towards instantaneous SLIPI phosphorescence thermometry is provided.

  6. Magnetic resonance imaging of iron storage diseases

    International Nuclear Information System (INIS)

    Yoshida, Hideo; Mano, Isamu; Asai, Sae; Yashiro, Naofumi; Itai, Yuji; Iio, Masahiro.

    1985-01-01

    We presented MRI findings of four patients of iron storage diseases with hemochromatosis and hemosiderosis. We examined detectavility of iron deposits with in vitro MR and X-CT observations of ferric (Fe 3+ ) solutions. Conculusion are as follows, 1) In detection of small amount of iron deposits, MRI is much better than X-CT. 2) MRI is a unique technique to detect iron deposits in bone marrow. 3) Early estimation of iron storage diseases will be promising using MRI technique. (author)

  7. Integrated image storage solution for the Cath department.

    Science.gov (United States)

    Weterings, R A

    1998-10-01

    Contemporary Image Storage systems for the Catheterization department manage and distribute digital cardiac images according to the "cine-film" paradigm. The images are digital, but the applications have not changed much. This situation will change in the near future. New systems are being developed to store additional (clinical related) data with X-ray Angiographic (XA) Images. Furthermore, the image storage domains are no longer an island in the hospital infrastructure. Efficiency requires the availability of images with other data at the various "point of care" locations. This in turn raises requirements and expectations about the standards in the area of application interoperability, since no single vendor can supply the complete solution. Recent DICOM (Digital Imaging and Communications in Medicine) standardization activities play an important role in extending the current scope of image oriented storage solutions towards a more integrated imaging and information (clinical) folder for the Cath department. The paper will address the following issues: New requirements on "self-contained" Image Storage solutions for the Cath lab. How to deal with the demand for interdepartmental communication using upcoming (new) DICOM standards and HL7 (Health Level Seven) in this area. The increasing influence of computer technology, replacing vendor-specific solutions by general-accepted standards from the Information Technology (IT) world. A step-wise approach to come to an integrated clinical (patient) folder with inherent capabilities for data interchange with other Cardiology departments and the hospitals information infrastructure.

  8. Effect of the phosphor screen optics on the Swank noise performance in indirect-conversion x-ray imaging detectors

    International Nuclear Information System (INIS)

    Lim, C H; Moon, M-K; Kam, S; Han, J C; Yun, S; Youn, H; Kim, H K; Jeon, H

    2014-01-01

    The optics between the scintillators and photodiode arrays of indirect-conversion x-ray imaging systems requires careful design because it can be a cause of secondary quantum sink, which reduces the detective quantum efficiency at high spatial frequencies. The aim of this study was the investigation of the effect of the optical properties of granular phosphor screens — including optical coupling materials and passivation layers in photodiode arrays — on the imaging performance of indirect-conversion x-ray imaging detectors using the Monte Carlo technique. In the Monte Carlo simulations, various design parameters were considered, such as the refractive index of the optical coupler and the passivation layer, the reflection coefficient at the screen backing, and the thickness of the optical coupler. We developed a model that describes the optical pulse-height distributions based on the depth-dependent collection efficiency obtained from the simulations. We used the model to calculate the optical Swank noise. A loss in the number of collected optical photons was inevitable owing to the introduction of intermediate optics and mismatches in the optical design parameters. However, the collection efficiency marginally affected the optical Swank factor performance. The results and methodology of this study will facilitate better designs and optimization of indirect-conversion x-ray detectors

  9. Industrial radiography with phosphor screens

    International Nuclear Information System (INIS)

    Broadhead, P.

    1981-01-01

    An experimental system that comprises a film of low silver content and a pair of high resolution phosphor intensifying screens and a commercial industrial X-ray film of similar speed are compared for image quality. It is concluded that the use of phosphor screens offers an increase in image quality when the information is limited by the graininess or quantum mottle of a radiograph which is frequently the case in practical radiography. (author)

  10. Mass-storage management for distributed image/video archives

    Science.gov (United States)

    Franchi, Santina; Guarda, Roberto; Prampolini, Franco

    1993-04-01

    The realization of image/video database requires a specific design for both database structures and mass storage management. This issue has addressed the project of the digital image/video database system that has been designed at IBM SEMEA Scientific & Technical Solution Center. Proper database structures have been defined to catalog image/video coding technique with the related parameters, and the description of image/video contents. User workstations and servers are distributed along a local area network. Image/video files are not managed directly by the DBMS server. Because of their wide size, they are stored outside the database on network devices. The database contains the pointers to the image/video files and the description of the storage devices. The system can use different kinds of storage media, organized in a hierarchical structure. Three levels of functions are available to manage the storage resources. The functions of the lower level provide media management. They allow it to catalog devices and to modify device status and device network location. The medium level manages image/video files on a physical basis. It manages file migration between high capacity media and low access time media. The functions of the upper level work on image/video file on a logical basis, as they archive, move and copy image/video data selected by user defined queries. These functions are used to support the implementation of a storage management strategy. The database information about characteristics of both storage devices and coding techniques are used by the third level functions to fit delivery/visualization requirements and to reduce archiving costs.

  11. Evaluation of Gd{sub 2}O{sub 2}S:Pr granular phosphor properties for X-ray mammography imaging

    Energy Technology Data Exchange (ETDEWEB)

    David, S.; Michail, C. [Department of Biomedical Engineering, Technological Educational Institute (TEI) of Athens, Ag. Spyridonos Street, 122 10 Egaleo (Greece); Seferis, I. [Department of Biomedical Engineering, Technological Educational Institute (TEI) of Athens, Ag. Spyridonos Street, 122 10 Egaleo (Greece); Faculty of Chemistry, Wroclaw University, 14F Joliot-Curie Street, 50-383 Wroclaw (Poland); Valais, I.; Fountos, G.; Liaparinos, P.; Kandarakis, I. [Department of Biomedical Engineering, Technological Educational Institute (TEI) of Athens, Ag. Spyridonos Street, 122 10 Egaleo (Greece); Kalyvas, N., E-mail: nkalyvas@teiath.gr [Department of Biomedical Engineering, Technological Educational Institute (TEI) of Athens, Ag. Spyridonos Street, 122 10 Egaleo (Greece)

    2016-01-15

    Phosphor materials are widely used in X-ray medical imaging detector applications, coupled with suitable photoreceptors. Upon the most demanding imaging modality is X-ray mammography, since the best defense against breast cancer is its early detection. A material suitable as a mammographic detector should efficiently absorb X-ray photons and transform them to optical photons, so as to minimize breast dose. The aim of the present study was to investigate the X-ray absorption efficiency and the absolute efficiency (AE), defined as the output optical photon power divided by the incident exposure, of Gd{sub 2}O{sub 2}S:Pr powder scintillator. For the purposes of this study, three scintillating screens with coating thicknesses, 34.1, 46.0 and 81.5 mg/cm{sup 2} respectively, were prepared in our laboratory from Gd{sub 2}O{sub 2}S:Pr powder (Phosphor Technology, Ltd.) by sedimentation on silica substrates. The quantum detection efficiency (QDE), the energy absorption efficiency (EAE), the spectral matching factor and the absolute efficiency (AE) were evaluated for X-ray mammographic conditions. Furthermore theoretical models were utilized to investigate the optical photon transmission properties through the phosphor mass. Gd{sub 2}O{sub 2}S:Pr presented high X-ray absorption properties and good spectral compatibility with several photoreceptors. It may be utilized for X-ray mammographic imaging if it is put in conjunction with a sensitive photoreceptor, so as to enhance Gd{sub 2}O{sub 2}S:Pr light emission properties. - Highlights: • Gd{sub 2}O{sub 2}S:Pr phosphor evaluated for mammography detectors. • The X-ray absorption efficiency was found high. • Spectral matching compatibility found for several photoreceptors. • X-ray absolute efficiency measured smaller than other phosphors. • Optical diffusion length and the light transmission per layer was theoretically calculated.

  12. Imaging camera system of OYGBR-phosphor-based white LED lighting

    Science.gov (United States)

    Kobashi, Katsuya; Taguchi, Tsunemasa

    2005-03-01

    The near-ultraviolet (nUV) white LED approach is analogous to three-color fluorescent lamp technology, which is based on the conversion of nUV radiation to visible light via the photoluminescence process in phosphor materials. The nUV light is not included in the white light generation from nUV-based white LED devices. This technology can thus provide a higher quality of white light than the blue and YAG method. A typical device demonstrates white luminescence with Tc=3,700 K, Ra > 93, K > 40 lm/W and chromaticity (x, y) = (0.39, 0.39), respectively. The orange, yellow, green and blue OYGB) or orange, yellow, red, green and blue (OYRGB) device shows a luminescence spectrum broader than of an RGB white LED and a better color rendering index. Such superior luminous characteristics could be useful for the application of several kinds of endoscope. We have shown the excellent pictures of digestive organs in a stomach of a dog due to the strong green component and high Ra.

  13. Storage and retrieval of large digital images

    Science.gov (United States)

    Bradley, J.N.

    1998-01-20

    Image compression and viewing are implemented with (1) a method for performing DWT-based compression on a large digital image with a computer system possessing a two-level system of memory and (2) a method for selectively viewing areas of the image from its compressed representation at multiple resolutions and, if desired, in a client-server environment. The compression of a large digital image I(x,y) is accomplished by first defining a plurality of discrete tile image data subsets T{sub ij}(x,y) that, upon superposition, form the complete set of image data I(x,y). A seamless wavelet-based compression process is effected on I(x,y) that is comprised of successively inputting the tiles T{sub ij}(x,y) in a selected sequence to a DWT routine, and storing the resulting DWT coefficients in a first primary memory. These coefficients are periodically compressed and transferred to a secondary memory to maintain sufficient memory in the primary memory for data processing. The sequence of DWT operations on the tiles T{sub ij}(x,y) effectively calculates a seamless DWT of I(x,y). Data retrieval consists of specifying a resolution and a region of I(x,y) for display. The subset of stored DWT coefficients corresponding to each requested scene is determined and then decompressed for input to an inverse DWT, the output of which forms the image display. The repeated process whereby image views are specified may take the form an interaction with a computer pointing device on an image display from a previous retrieval. 6 figs.

  14. Embedded system of image storage based on fiber channel

    Science.gov (United States)

    Chen, Xiaodong; Su, Wanxin; Xing, Zhongbao; Wang, Hualong

    2008-03-01

    In domains of aerospace, aviation, aiming, and optic measure etc., the embedded system of imaging, processing and recording is absolutely necessary, which has small volume, high processing speed and high resolution. But the embedded storage technology becomes system bottleneck because of developing slowly. It is used to use RAID to promote storage speed, but it is unsuitable for the embedded system because of its big volume. Fiber channel (FC) technology offers a new method to develop the high-speed, portable storage system. In order to make storage subsystem meet the needs of high storage rate, make use of powerful Virtex-4 FPGA and high speed fiber channel, advance a project of embedded system of digital image storage based on Xilinx Fiber Channel Arbitrated Loop LogiCORE. This project utilizes Virtex- 4 RocketIO MGT transceivers to transmit the data serially, and connects many Fiber Channel hard drivers by using of Arbitrated Loop optionally. It can achieve 400MBps storage rate, breaks through the bottleneck of PCI interface, and has excellences of high-speed, real-time, portable and massive capacity.

  15. Acoustic imaging of underground storage tank wastes

    International Nuclear Information System (INIS)

    Mech, S.J.

    1995-09-01

    Acoustics is a potential tool to determine the properties of high level wastes stored in Underground Storage Tanks. Some acoustic properties were successfully measured by a limited demonstration conducted in 114-TX. This accomplishment provides the basis for expanded efforts to qualify techniques which depend on the acoustic properties of tank wastes. This work is being sponsored by the Department of Energy under the Office of Science and Technology. In FY-1994, limited Tank Waste Remediation Systems EM-30 support was available at Hanford and Los Alamos National Laboratory. The Massachusetts Institute of Technology (MIT) and Earth Resources Laboratory (ERL) were engaged for analysis support, and Elohi Geophysics, Inc. for seismic testing services. Westinghouse-Hanford Company provided the testing and training, supplied the special engineering and safety analysis equipment and procedures, and provided the trained operators for the actual tank operations. On 11/9/94, limited in-tank tests were successfully conducted in tank 114-TX. This stabilized Single Shell Tank was reported as containing 16.8 feet of waste, the lower 6.28 feet of which contained interstitial liquid. Testing was conducted over the lower 12 feet, between two Liquid Observation Wells thirty feet apart. The ''quick-look'' data was reviewed on-site by MIT and Elohi

  16. 21 CFR 892.2010 - Medical image storage device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical image storage device. 892.2010 Section 892.2010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED..., and digital memory. (b) Classification. Class I (general controls). The device is exempt from the...

  17. Oxidizer in phosphoric reactors

    International Nuclear Information System (INIS)

    Santos Benedetto, J. dos

    1985-01-01

    Oxidation during the manufacture of wet-process phosphoric acid affected the distribution of uranium and impurities between phosphoric acid and gypsum, by decreasing the uranium loss to gypsum and the impurities solubilization in phosphoric acid. (Author) [pt

  18. Improvements in phosphors

    International Nuclear Information System (INIS)

    Rabatin, J.G.

    1981-01-01

    For X-ray image converter applications, especially when used in medical radiography, it is desirable to improve the speed and brightness of response for conversion of X-rays in phosphors. The rare earth oxyhalide phosphors coactivated with a combination of rare earth activators described in this patent are capable of exhibiting low afterglow with high ultraviolet emission. They have the general formula Lnsub(1-y-w)OX:Tbsub(y)Tmsub(w) where Ln is lanthanum or gadolinium, X is chlorine and/or bromine, y is from 0.0005 to 0.010 moles per mole and w is from 0.00005 to 0.005 moles per mole of the Lnsub(1-y-w)OX host. The method of preparation and characteristics of speed, afterglow and UV emission are described. (U.K.)

  19. PACS and the digital storage of medical images

    International Nuclear Information System (INIS)

    Perry, J.R.; Johnston, R.E.; Pizer, S.M.; Lowendorf, D.D.; Rogers, D.C.; Thompson, B.C.; Parrish, D.M.; Brenton, B.C.; Staab, E.V.

    1986-01-01

    An application of computers in medicine is developing wherein large amounts of digital information in the form of images must be stored, retrieved, and displayed quickly. In radiology this application most commonly goes by the acronym PACS which stands for picture archival and communications system. Estimates of the storage requirements for radiologic images strongly suggest that we should think in terms of terabytes per year for a 150,000 procedure/year, 600 bed hospital. Transmission of patient image data files (a single X-ray image pair may be 12.6 Mbytes) arouses concern over transmission speeds, user waiting tolerances and a communications standard. An important accord is being reached between users and equipment manufacturers in radiology for a standard communications protocol, called the proposed ACR-NEMA standard. Features of PACS which require high speed computational abilities include a lexicon for report generation and image reconstruction, compression, enhancement and 3D display

  20. Medical image digital archive: a comparison of storage technologies

    Science.gov (United States)

    Chunn, Timothy; Hutchings, Matt

    1998-07-01

    A cost effective, high capacity digital archive system is one of the remaining key factors that will enable a radiology department to eliminate film as an archive medium. The ever increasing amount of digital image data is creating the need for huge archive systems that can reliably store and retrieve millions of images and hold from a few terabytes of data to possibly hundreds of terabytes. Selecting the right archive solution depends on a number of factors: capacity requirements, write and retrieval performance requirements, scaleability in capacity and performance, conformance to open standards, archive availability and reliability, security, cost, achievable benefits and cost savings, investment protection, and more. This paper addresses many of these issues. It compares and positions optical disk and magnetic tape technologies, which are the predominant archive mediums today. New technologies will be discussed, such as DVD and high performance tape. Price and performance comparisons will be made at different archive capacities, plus the effect of file size on random and pre-fetch retrieval time will be analyzed. The concept of automated migration of images from high performance, RAID disk storage devices to high capacity, NearlineR storage devices will be introduced as a viable way to minimize overall storage costs for an archive.

  1. A preliminary investigation of the imaging performance of photostimulable phosphor computed radiography using a new design of mammographic quality control test object

    International Nuclear Information System (INIS)

    Cowen, A.R.; Brettle, D.S.; Coleman, N.J.; Parkin, G.J.S.

    1992-01-01

    Leeds Test Object TOR[MAM] has been designed to supplement the current FAXIL mammography test object TOR[MAX]. It contains a range of details that have a more natural radiographic appearance and has been designed as a test that more closely approximates the image quality achieved in clinical mammography. Physical aspects of the design and implementation of TOR[MAM] are presented. The TOR[MAM] has been used in a preliminary physical evaluation of the comparative image qualities produced by conventional (screen-film) and phostostimulable phosphor computed mammography and the results are discussed. TOR[MAX] results are also presented. The influence of digital image processing (enhancement) on the image quality of computed mammograms is also considered. The results presented indicate the sensitivity of TOR[MAM]. (author)

  2. An Intelligent Cloud Storage Gateway for Medical Imaging.

    Science.gov (United States)

    Viana-Ferreira, Carlos; Guerra, António; Silva, João F; Matos, Sérgio; Costa, Carlos

    2017-09-01

    Historically, medical imaging repositories have been supported by indoor infrastructures. However, the amount of diagnostic imaging procedures has continuously increased over the last decades, imposing several challenges associated with the storage volume, data redundancy and availability. Cloud platforms are focused on delivering hardware and software services over the Internet, becoming an appealing solution for repository outsourcing. Although this option may bring financial and technological benefits, it also presents new challenges. In medical imaging scenarios, communication latency is a critical issue that still hinders the adoption of this paradigm. This paper proposes an intelligent Cloud storage gateway that optimizes data access times. This is achieved through a new cache architecture that combines static rules and pattern recognition for eviction and prefetching. The evaluation results, obtained from experiments over a real-world dataset, show that cache hit ratios can reach around 80%, leading to reductions of image retrieval times by over 60%. The combined use of eviction and prefetching policies proposed can significantly reduce communication latency, even when using a small cache in comparison to the total size of the repository. Apart from the performance gains, the proposed system is capable of adjusting to specific workflows of different institutions.

  3. Challenges for data storage in medical imaging research.

    Science.gov (United States)

    Langer, Steve G

    2011-04-01

    Researchers in medical imaging have multiple challenges for storing, indexing, maintaining viability, and sharing their data. Addressing all these concerns requires a constellation of tools, but not all of them need to be local to the site. In particular, the data storage challenges faced by researchers can begin to require professional information technology skills. With limited human resources and funds, the medical imaging researcher may be better served with an outsourcing strategy for some management aspects. This paper outlines an approach to manage the main objectives faced by medical imaging scientists whose work includes processing and data mining on non-standard file formats, and relating those files to the their DICOM standard descendents. The capacity of the approach scales as the researcher's need grows by leveraging the on-demand provisioning ability of cloud computing.

  4. Practical applications of phosphors

    CERN Document Server

    Yen, William M; Yamamoto, Hajime

    2006-01-01

    Drawn from the second edition of the best-selling Phosphor Handbook, Practical Applications of Phosphors outlines methods for the production of various phosphors and discusses a broad spectrum of applications. Beginning with methods for synthesis and related technologies, the book sets the stage by classifying and then explaining practical phosphors according to usage. It describes the operating principle and structure of phosphor devices and the phosphor characteristics required for a given device, then covers the manufacturing processes and characteristics of phosphors. The book discusses research and development currently under way on phosphors with potential for practical usage and touches briefly on phosphors that have played a historical role, but are no longer of practical use. It provides a comprehensive treatment of applications including lamps and cathode-ray tubes, x-ray and ionizing radiation, and for vacuum fluorescent and field emission displays and covers inorganic and organic electroluminescen...

  5. Optimal image resolution for digital storage of radiotherapy-planning images

    International Nuclear Information System (INIS)

    Baba, Yuji; Furusawa, Mitsuhiro; Murakami, Ryuji; Baba, Takashi; Yokoyama, Toshimi; Nishimura, Ryuichi; Takahashi, Mutsumasa

    1998-01-01

    Purpose: To evaluate the quality of digitized radiation-planning images at different resolution and to determine the optimal resolution for digital storage. Methods and Materials: Twenty-five planning films were scanned and digitized using a film scanner at a resolution of 72 dots per inch (dpi) with 8-bit depth. The resolution of scanned images was reduced to 48, 36, 24, and 18 dpi using computer software. Image qualities of these five images (72, 48, 36, 24, and 18 dpi) were evaluated and given scores (4 = excellent; 3 = good; 2 = fair; and 1 = poor) by three radiation oncologists. An image data compression algorithm by the Joint Photographic Experts Group (JPEG) (not reversible and some information will be lost) was also evaluated. Results: The scores of digitized images with 72, 48, 36, 24, and 17 dpi resolution were 3.8 ± 0.3, 3.5 ± 0.3, 3.3 ± 0.5, 2.7 ± 0.5, and 1.6 ± 0.3, respectively. The quality of 36-dpi images were definitely worse compared to 72-dpi images, but were good enough as planning films. Digitized planning images with 72- and 36-dpi resolution requires about 800 and 200 KBytes, respectively. The JPEG compression algorithm produces little degradation in 36-dpi images at compression ratios of 5:1. Conclusion: The quality of digitized images with 36-dpi resolution was good enough as radiation-planning images and required 200 KBytes/image

  6. The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

    International Nuclear Information System (INIS)

    Kajan, Zahra Dalili; Davalloo, Reza Tayefeh; Tavangar, Mayam; Valizade, Fatemeh

    2015-01-01

    Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying 'Sharpening 2' and 'Noise Reduction' processing options to the original images; (2) applying the 'Magnification 1:3' option to the image obtained in the first step; (3) enhancing the original images by using the 'Diagonal/' option; (4) reviewing the changes brought about by the third step of image processing and then, applying 'Magnification 1:3'; (5) applying 'Sharpening UM' to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying 'Magnification 1:3.' Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). This study shows that the application of 'Sharpening UM' along with the 'Magnification 1:3' processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.

  7. The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

    Energy Technology Data Exchange (ETDEWEB)

    Kajan, Zahra Dalili; Davalloo, Reza Tayefeh; Tavangar, Mayam; Valizade, Fatemeh [Faculty of Dentistry, Guilan University of Medical Sciences, Rasht (Iran, Islamic Republic of)

    2015-06-15

    Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying 'Sharpening 2' and 'Noise Reduction' processing options to the original images; (2) applying the 'Magnification 1:3' option to the image obtained in the first step; (3) enhancing the original images by using the 'Diagonal/' option; (4) reviewing the changes brought about by the third step of image processing and then, applying 'Magnification 1:3'; (5) applying 'Sharpening UM' to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying 'Magnification 1:3.' Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). This study shows that the application of 'Sharpening UM' along with the 'Magnification 1:3' processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.

  8. Rare earth phosphors and phosphor screens

    International Nuclear Information System (INIS)

    Buchanan, R.A.; Maple, T.G.; Sklensky, A.F.

    1981-01-01

    Advances in the use of stabilized rare earth phosphors and of conversion screens using these materials are examined. In particular the new phosphors discussed in this invention consist of oxybromides of yttrium, lanthanum and gadolinium with a luminescent activator ion stabilized by an oxychloride or oxyfluoride surface layer and the conversion screens include trivalent cerium as the activator ion. (U.K.)

  9. Phase-image-based content-addressable holographic data storage

    Science.gov (United States)

    John, Renu; Joseph, Joby; Singh, Kehar

    2004-03-01

    We propose and demonstrate the use of phase images for content-addressable holographic data storage. Use of binary phase-based data pages with 0 and π phase changes, produces uniform spectral distribution at the Fourier plane. The absence of strong DC component at the Fourier plane and more intensity of higher order spatial frequencies facilitate better recording of higher spatial frequencies, and improves the discrimination capability of the content-addressable memory. This improves the results of the associative recall in a holographic memory system, and can give low number of false hits even for small search arguments. The phase-modulated pixels also provide an opportunity of subtraction among data pixels leading to better discrimination between similar data pages.

  10. Process of radiation damage in BaFX:Eu2+ (X=Br, I) photo-stimulable phosphor for imaging plate (IP)

    International Nuclear Information System (INIS)

    Kato, Munetaka; Takahashi, Kenji

    2005-01-01

    Imaging Plate (IP) is a 2-dimensional radiation detector utilizing photo-stimulable phosphors. Photo-stimulated luminescence (PSL) is a kind of process in radiation-induced reactions and IP can be repeatedly performed. The mechanism of PSL is reviewed and the radiation damage, which is a phenomenon that the luminescence goes down under X-ray irradiation, is also referred to. The relation between the composition of BaFX: Eu 2+ (X=Br, I), which is widely used in IPs, and the degree of radiation damage is investigated. The degree of radiation damage is smaller in the mixed crystal system of Br and I such as BaFBr 0.85 I 0.15 :Eu 2+ than in BaFBr: Eu 2+ and BaFI: Eu 2+ . This is explained by the characteristics of luminescence centers and F centers under X-ray irradiation. (author)

  11. Fundamentals of phosphors

    CERN Document Server

    Yen, William M; Yamamoto, Hajime

    2006-01-01

    Drawing from the second edition of the best-selling Handbook of Phosphors, Fundamentals of Phosphors covers the principles and mechanisms of luminescence in detail and surveys the primary phosphor materials as well as their optical properties. The book addresses cutting-edge developments in phosphor science and technology including oxynitride phosphors and the impact of lanthanide level location on phosphor performance.Beginning with an explanation of the physics underlying luminescence mechanisms in solids, the book goes on to interpret various luminescence phenomena in inorganic and organic materials. This includes the interpretation of the luminescence of recently developed low-dimensional systems, such as quantum wells and dots. The book also discusses the excitation mechanisms by cathode-ray and ionizing radiation and by electric fields to produce electroluminescence. The book classifies phosphor materials according to the type of luminescence centers employed or the class of host materials used and inte...

  12. The Impact Of Optical Storage Technology On Image Processing Systems

    Science.gov (United States)

    Garges, Daniel T.; Durbin, Gerald T.

    1984-09-01

    The recent announcement of commercially available high density optical storage devices will have a profound impact on the information processing industry. Just as the initial introduction of random access storage created entirely new processing strategies, optical technology will allow dramatic changes in the storage, retrieval, and dissemination of engineering drawings and other pictorial or text-based documents. Storage Technology Corporation has assumed a leading role in this arena with the introduction of the 7600 Optical Storage Subsystem, and the formation of StorageTek Integrated Systems, a subsidiary chartered to incorporate this new technology into deliverable total systems. This paper explores the impact of optical storage technology from the perspective of a leading-edge manufacturer and integrator.

  13. Phosphor scintillator structure

    International Nuclear Information System (INIS)

    Cusano, D.A.; Prener, J.S.

    1980-01-01

    A method of fabricating scintillators is described in which the phosphor is distributed within the structure in such a way as to enhance the escape of the visible wavelength radiation that would otherwise be dissipated within the scintillator body. Two embodiments of the present invention are disclosed: one in which the phosphor is distributed in a layered structure and another in which the phosphor is dispersed throughout a transparent matrix. (U.K.)

  14. Myocardial imaging with a radioiodinated norepinephrine storage analog

    International Nuclear Information System (INIS)

    Wieland, D.M.; Brown, L.E.; Rogers, W.L.; Worthington, K.C.; Wu, J.L.; Clinthorne, N.H.; Otto, C.A.; Swanson, D.P.; Beierwaltes, W.H.

    1981-01-01

    Meta-iodobenzylguanidine (M-IBG), an iodinated aromatic analog of the hypotensive drug guanethidine, localizes in the heart of the rat, dog, and rhesus monkey. A comparative study of tissue distribution in the dog has been performed with five myocardiophilic agents: thallium-201, I-125 16-iodohexadecanoic acid, H-3 norepinephrine, C-14 guanethidine and I-125 M-IBG. The last two compounds give heart concentrations and heart-to-blood concentration ratios similar to those of thallium-201. Planar and tomographic images of the hearts of the dog and rhesus monkey were obtained using I-131 or I-123 labeled M-IBG. Blocking studies with reserpine suggest that a major component of myocardial retention of M-IBG is sequestration within the norepinephrine storage vesicles of the adrenergic nerves. The localization of M-IBG in other organs with rich sympathetic innervation and the relative insensitivity of myocardial uptake to a wide range of loading doses lend additional support for a neuronal mode of retention

  15. The feasibility of boron containing phosphors in thermal neutron image plates, in particular the systems M sub 2 B sub 5 O sub 9 X : Eu sup 2 sup + (M=Ca, Sr, Ba; X=Cl, Br) Part II: experimental results

    CERN Document Server

    Knitel, M J; Dorenbos, P; Eijk, C W E; Berezovskaya, I V; Dotsenko, V

    2000-01-01

    The storage phosphor properties of the compounds M sub 2 B sub 5 O sub 9 X : Eu sup 2 sup + (M=Ca, Sr, Ba; X=Cl, Br) have been studied. The best compounds, Sr sub 2 B sub 5 O sub 9 Br : Eu sup 2 sup + and Ca sub 2 B sub 5 O sub 9 Br : Eu sup 2 sup + , show a photostimulated luminescence yield of, respectively, 21 and 14 photons per incident thermal neutron. They contain natural boron. With these yields, image plates with detective quantum efficiency values of more than 40% are envisaged when using enriched sup 1 sup 0 B, but the stimulation energy at 633 nm is too high.

  16. Image storage and permanence considerations in the long-term preservation of photographic images - update 2010

    International Nuclear Information System (INIS)

    LaBarca, Joseph E

    2010-01-01

    Archivists and consumers, alike, need to become aware of long-term storage and preservation issues that relate to the preservation of the data behind digital photographic images. The more obvious issues, such as accidental or catastrophic data loss and hardware format evolution, are only now being recognized in the archiving community. Consumers need to be alerted to these issues and be prepared to develop preservation strategies as well. However, longer-term issues beyond routine backup and migration of data need to be considered. The very basic solution of preservation via hardcopy images stored in shoeboxes or albums is one option, but this raises a fundamental question regarding image preservation that transcends even the more complex solutions-the long-term stability of the chosen media, whether digital or analog. This paper discusses archiving and preservation as it relates to images, and the data behind those images, along with historical perspectives and an overview of possible longer-term preservation strategies. The importance of image permanence standards, as they relate to overall selection of preservation strategies, will also be discussed.

  17. A Study of NetCDF as an Approach for High Performance Medical Image Storage

    International Nuclear Information System (INIS)

    Magnus, Marcone; Prado, Thiago Coelho; Von Wangenhein, Aldo; De Macedo, Douglas D J; Dantas, M A R

    2012-01-01

    The spread of telemedicine systems increases every day. The systems and PACS based on DICOM images has become common. This rise reflects the need to develop new storage systems, more efficient and with lower computational costs. With this in mind, this article discusses a study for application in NetCDF data format as the basic platform for storage of DICOM images. The study case comparison adopts an ordinary database, the HDF5 and the NetCDF to storage the medical images. Empirical results, using a real set of images, indicate that the time to retrieve images from the NetCDF for large scale images has a higher latency compared to the other two methods. In addition, the latency is proportional to the file size, which represents a drawback to a telemedicine system that is characterized by a large amount of large image files.

  18. MO-FG-303-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Automating LINAC QA: Design and Testing of An Image Acquisition and Processing System Utilizing a Combination of Radioluminescent Phosphors, Embedded X-Ray Markers and Optical Measurements

    International Nuclear Information System (INIS)

    Jenkins, C; Naczynski, D; Yu, S; Xing, L

    2015-01-01

    Purpose: The recent development of phosphors to visualize radiation beams from linear accelerators (LINAC) offers a unique opportunity for evaluating radiation fields within the context of the treatment space. The purpose of this study was to establish an automated, self-calibrating prototype system for performing quality assurance (QA) measurements. Methods: A thin layer of Gd 2 O 2 S:Tb phosphor and fiducial markers were embedded on several planar faces of a custom-designed phantom. The phantom was arbitrarily placed near iso-center on the couch of a LINAC equipped with on-board megavoltage (MV) and kilovoltage (kV) imagers. A plan consisting of several beams and integrated image acquisitions was delivered. Images of the phantom were collected throughout the delivery. Salient features, such as fiducials, crosshairs and beam edges were then extracted from these images used to calibrate the system, adjust for variations in phantom placement, and perform measurements. Beam edges were visualized by imaging the light generated by the phosphor on the phantom enabling direct comparison with the light field and laser locations. Registration of MV, kV and optical image data was performed using the embedded fiducial markers, enabling comparison of imaging center locations. Measurements specified by TG-142 were calculated and compared with those obtained from a commercially available QA system. Results: The system was able to automatically extract the location of the fiducials, lasers, light field and radiation field from the acquired images regardless of phantom positioning. It was also able to automatically identify the locations of fiducial markers on kV and MV images. All collected measurements were within TG-142 guidelines. The difference between the prototype and commercially available system were less than 0.2 mm. Conclusion: The prototype system demonstrated the capability of accurately and autonomously evaluating various TG-142 parameters independent of operator

  19. A Mathematical Model for Storage and Recall of Images using Targeted Synchronization of Coupled Maps.

    Science.gov (United States)

    Palaniyandi, P; Rangarajan, Govindan

    2017-08-21

    We propose a mathematical model for storage and recall of images using coupled maps. We start by theoretically investigating targeted synchronization in coupled map systems wherein only a desired (partial) subset of the maps is made to synchronize. A simple method is introduced to specify coupling coefficients such that targeted synchronization is ensured. The principle of this method is extended to storage/recall of images using coupled Rulkov maps. The process of adjusting coupling coefficients between Rulkov maps (often used to model neurons) for the purpose of storing a desired image mimics the process of adjusting synaptic strengths between neurons to store memories. Our method uses both synchronisation and synaptic weight modification, as the human brain is thought to do. The stored image can be recalled by providing an initial random pattern to the dynamical system. The storage and recall of the standard image of Lena is explicitly demonstrated.

  20. Prior-Based Quantization Bin Matching for Cloud Storage of JPEG Images.

    Science.gov (United States)

    Liu, Xianming; Cheung, Gene; Lin, Chia-Wen; Zhao, Debin; Gao, Wen

    2018-07-01

    Millions of user-generated images are uploaded to social media sites like Facebook daily, which translate to a large storage cost. However, there exists an asymmetry in upload and download data: only a fraction of the uploaded images are subsequently retrieved for viewing. In this paper, we propose a cloud storage system that reduces the storage cost of all uploaded JPEG photos, at the expense of a controlled increase in computation mainly during download of requested image subset. Specifically, the system first selectively re-encodes code blocks of uploaded JPEG images using coarser quantization parameters for smaller storage sizes. Then during download, the system exploits known signal priors-sparsity prior and graph-signal smoothness prior-for reverse mapping to recover original fine quantization bin indices, with either deterministic guarantee (lossless mode) or statistical guarantee (near-lossless mode). For fast reverse mapping, we use small dictionaries and sparse graphs that are tailored for specific clusters of similar blocks, which are classified via tree-structured vector quantizer. During image upload, cluster indices identifying the appropriate dictionaries and graphs for the re-quantized blocks are encoded as side information using a differential distributed source coding scheme to facilitate reverse mapping during image download. Experimental results show that our system can reap significant storage savings (up to 12.05%) at roughly the same image PSNR (within 0.18 dB).

  1. Unactivated yttrium tantalate phosphor

    International Nuclear Information System (INIS)

    Reddy, V.B.; Cheung, H.K.

    1992-01-01

    This patent describes an unactivated yttrium tantalate phosphor having M prime monoclinic structure and containing one or more additives of Rb and Al in an amount of between about 0.001 to 0.1 moles per mole of yttrium tantalate to improve brightness under X-radiation. This patent also describes an unactivated yttrium tantalate phosphor having M prime monoclinic structure and containing additives of Sr in an amount of between 0.001 to 0.1 moles per mole of yttrium tantalate and one or more of Rb and Al in an amount of between 0.001 to 0.1 moles per mole of yttrium tantalate the phosphor exhibiting a greater brightness under X-radiation than the phosphor absent Rb and Al

  2. Low lag luminescent phosphors

    International Nuclear Information System (INIS)

    1976-01-01

    The addition of potassium or rubidium salts to europium-activated fluorohalide phosphors produces X-ray screens with low lag, even at very low europium concentrations. The chemical preparation and afterglow test results are described

  3. Phosphors for LED lamps

    Science.gov (United States)

    Murphy, James Edward; Manepalli, Satya Kishore; Kumar, Prasanth Nammalwar

    2013-08-13

    A phosphor, a phosphor blend including the phosphor, a phosphor prepared by a process, and a lighting apparatus including the phosphor blend are disclosed. The phosphor has the formula (Ca.sub.1-p-qCe.sub.pK.sub.q).sub.xSc.sub.y(Si.sub.1-rGa.sub.r).sub.zO.su- b.12+.delta. or derived from a process followed using disclosed amounts of reactants. In the formula, (0

  4. High temperature thermometric phosphors

    Science.gov (United States)

    Allison, Stephen W.; Cates, Michael R.; Boatner, Lynn A.; Gillies, George T.

    1999-03-23

    A high temperature phosphor consists essentially of a material having the general formula LuPO.sub.4 :Dy.sub.(x),Eu.sub.y) wherein: 0.1 wt %.ltoreq.x.ltoreq.20 wt % and 0.1 wt %.ltoreq.y.ltoreq.20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopent. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions.

  5. X-ray or UV-ray imaging sensor utilizing optically stimulated luminescence phenomenon in Eu-doped KCl phosphors

    International Nuclear Information System (INIS)

    Nanto, Hidehito; Murayama, Kazuhiko; Hirai, Yoshiaki; Taniguchi, Shin-ichi; Makamura, Shouichi; Takeuchi, Nozomu.

    1993-01-01

    An intense OSL with a peak at about 420 [nm] has been observed by stimulating an X-ray or UV-ray irradiated KCl: Eu crystal with F-band light whose wavelength is about 560 [um]. A possible excitation and emission mechanisms for the 420 [um] OSL peak X-ray or UV-ray irradiated sample is proposed. It is found that the OSL intensity is proportional to the X-ray absorbed dose or UV-ray irradiation dose. It is also found that X-ray or UV-ray irradiated KCl; Eu exhibited excellent fading characteristics. These results strongly suggest that the KCl: Eu is one of the most attractive candidates for two-dimensional X-ray or UV-ray imaging sensor utilizing the OSL phenomenon. (J.P.N.)

  6. Enhancing security of DICOM images during storage and ...

    Indian Academy of Sciences (India)

    Brain tumour Image is in DICOM standard (Rosslyn 1996) in which the patient informa- tion including name, birth date, gender, history are included in object classes. This information is sensitive to the patient and important for radiologist diagnosis. Data security becomes an important issue when brain tumour images are ...

  7. Wet chemical synthesis of LiBaF{sub 3} phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Vartika S., E-mail: svmoharil@yahoo.com [Physics Department, Shri Ramdeobaba K.N. Engineering College, Katol Road, Nagpur 440 013 (India); Joshi, C.P. [Physics Department, Shri Ramdeobaba K.N. Engineering College, Katol Road, Nagpur 440 013 (India); Moharil, S.V. [Department of Physics, R.T.M. Nagpur University, Nagpur 440 010 (India)

    2013-12-05

    Highlights: •LiBaF{sub 3}:RE{sup 3+} phosphors synthesized by a simple wet chemical method. •Ce{sup 3+} and Tb{sup 3+} emissions observed in as-prepared powders without any thermal treatment. •Intense Eu{sup 2+} emission observed after annealing in reductive atmosphere. -- Abstract: LiBaF{sub 3} has great potential applications as X-ray storage phosphor, slow neutron imaging, scintillator, vacuum ultraviolet (VUV) optical lithography, etc. Conventionally, LiBaF{sub 3} is prepared by solid state reaction between the constituent fluorides. However, the preparation of phase pure material and especially single crystals is rather tricky due to incongruent melting. For the first time, a wet chemical preparation of rare earth activated LiBaF{sub 3} is described here. As precipitated powders containing Ce{sup 3+} or Tb{sup 3+} exhibited characteristic luminescence. For observing Eu{sup 2+} emission, it was necessary to heat the powders in a reductive atmosphere. It is suggested that phosphors prepared by this method may prove useful in applications like OSL, X-ray imaging, etc. which do not require large single crystals.

  8. Technical Considerations of Phosphorous-32 Bremsstrahlung SPECT Imaging after Radio embolization of Hepatic Tumors: A Clinical Assessment with a Review of Imaging Parameters

    International Nuclear Information System (INIS)

    Pirayesh, E.; Amoui, M.; Khorrami, M.; Akhlaghpoor, Sh.; Tolooee, Sh.; PoorBeigi, H.; Sheibani, Sh.; Assadi, M.

    2014-01-01

    Bremsstrahlung (BS) imaging during radio embolization (RE) confirms the deposition of radiotracer in hepatic/extrahepatic tumors. The aim of this study is to demonstrate '3 2 P images and to optimize the imaging parameters. Materials and Methods. Thirty-nine patients with variable types of hepatic tumors, treated with the intra-arterial injection of 32 P, were included. All patients underwent BS SPECT imaging 24-72 h after tracer administration, using low energy high resolution (LEHR) (18 patients) or medium energy general purpose (MEGP) (21 patients) collimators. A grading scale from 1 to 4 was used to express the compatibility of the 32 P images with those obtained from CT/MRI. Results. Although the image quality obtained with the MEGP collimator was visually and quantitatively better than with the LEHR (76% concordance score versus 71%, resp.), there was no statistically significant difference between them. Conclusion. The MEGP collimator is the first choice for BS SPECT imaging. However, if the collimator change is time consuming (as in a busy center) or an MEGP collimator is not available, the LEHR collimator could be practical with acceptable images, especially in a SPECT study. In addition, BS imaging is a useful method to confirm the proper distribution of radiotherapeutic agents and has good correlation with anatomical findings.

  9. Modeling granular phosphor screens by Monte Carlo methods

    International Nuclear Information System (INIS)

    Liaparinos, Panagiotis F.; Kandarakis, Ioannis S.; Cavouras, Dionisis A.; Delis, Harry B.; Panayiotakis, George S.

    2006-01-01

    The intrinsic phosphor properties are of significant importance for the performance of phosphor screens used in medical imaging systems. In previous analytical-theoretical and Monte Carlo studies on granular phosphor materials, values of optical properties, and light interaction cross sections were found by fitting to experimental data. These values were then employed for the assessment of phosphor screen imaging performance. However, it was found that, depending on the experimental technique and fitting methodology, the optical parameters of a specific phosphor material varied within a wide range of values, i.e., variations of light scattering with respect to light absorption coefficients were often observed for the same phosphor material. In this study, x-ray and light transport within granular phosphor materials was studied by developing a computational model using Monte Carlo methods. The model was based on the intrinsic physical characteristics of the phosphor. Input values required to feed the model can be easily obtained from tabulated data. The complex refractive index was introduced and microscopic probabilities for light interactions were produced, using Mie scattering theory. Model validation was carried out by comparing model results on x-ray and light parameters (x-ray absorption, statistical fluctuations in the x-ray to light conversion process, number of emitted light photons, output light spatial distribution) with previous published experimental data on Gd 2 O 2 S:Tb phosphor material (Kodak Min-R screen). Results showed the dependence of the modulation transfer function (MTF) on phosphor grain size and material packing density. It was predicted that granular Gd 2 O 2 S:Tb screens of high packing density and small grain size may exhibit considerably better resolution and light emission properties than the conventional Gd 2 O 2 S:Tb screens, under similar conditions (x-ray incident energy, screen thickness)

  10. Determining storage related egg quality changes via digital image ...

    African Journals Online (AJOL)

    Area and length measurements related to exterior and interior egg quality were determined by digital image analysis. In general, excluding the outer thin albumen area, all of the area measurements such as total egg content area and inner thick albumen area were larger in stored eggs than in fresh eggs (52.28 vs.

  11. Design and Verification of Remote Sensing Image Data Center Storage Architecture Based on Hadoop

    Science.gov (United States)

    Tang, D.; Zhou, X.; Jing, Y.; Cong, W.; Li, C.

    2018-04-01

    The data center is a new concept of data processing and application proposed in recent years. It is a new method of processing technologies based on data, parallel computing, and compatibility with different hardware clusters. While optimizing the data storage management structure, it fully utilizes cluster resource computing nodes and improves the efficiency of data parallel application. This paper used mature Hadoop technology to build a large-scale distributed image management architecture for remote sensing imagery. Using MapReduce parallel processing technology, it called many computing nodes to process image storage blocks and pyramids in the background to improve the efficiency of image reading and application and sovled the need for concurrent multi-user high-speed access to remotely sensed data. It verified the rationality, reliability and superiority of the system design by testing the storage efficiency of different image data and multi-users and analyzing the distributed storage architecture to improve the application efficiency of remote sensing images through building an actual Hadoop service system.

  12. Design and performance of a passive dosimeter consisting of a stack of photostimulable phosphor (PSP) imaging plates (IP) based on BaF(Br, I):Eu2+

    International Nuclear Information System (INIS)

    Jean-Paul Negre

    2011-07-01

    This manuscript presents an original concept of passive, lightweight, and compact dosimeter based on a stack of BaFBr:Eu 2+ photostimulable phosphor plates (Image Plate) alternating with high-Z metal screens. It describes the manufacture and the method to calibrate the dosimeter. This method consists in using a Co 60 standard source and Monte Carlo N-Particle codes (MCNPX/MCNP5) to apply them to a large area of radiation energies, such as quasi mono-energetic radiation (Gamma rays decay of radioactive isotope, X-ray fluorescence), or continuous radiation spectra (Bremsstrahlung radiation, synchrotron light source). The measurement recurrence in the stack of couples 'metallic foil / IP' ensures consistency measurements, determines the threshold depth of electronic equilibrium (depending on the radiation energy) and allows us to infer the absolute dose in air (Kerma). The depth-dose curve in the stack and transmission measurements provide an estimate of the effective energy of incident radiations, report the presence of parasite scattered radiations and allow us to discriminate the nature of ionizing particles. The 2D features of the device are used to characterize the ballistic fate of charged particles in material thickness, which is of great interest with narrow particles beams. This dosimeter has remarkable advantages over other passive dosimeters, including a dynamic range larger than 10 7 of linear photon dose detection from less than 0.5 μGy and up to several Gy for radiation energies between a few tens of keV and more than 10 MeV (20 MeV with Bremsstrahlung X-ray spectra). This concept originality consists in almost immediately getting the measurement results after an exposure and a single pass reading of the dosimeter. It can respond positively to most of the usual needs in radiation metrology: personal or environmental dosimetry (radiation protection); Controls / characterization / mapping around materials and emitting ionizing radiation devices

  13. Phosphates and phosphoric acid

    Energy Technology Data Exchange (ETDEWEB)

    Becker, P [Compagnie Francaise de l' Azote, Paris (France)

    1983-01-01

    In chapter 8.5 the following aspects of uranium recovery are treated: basis of extraction process, extraction principle, solvents, strength of the acid to be treated, technology, main processes in use, impact of uranium recovery on phosphoric acid plants, and economics of uranium recovery plants.

  14. Distributed Storage Algorithm for Geospatial Image Data Based on Data Access Patterns.

    Directory of Open Access Journals (Sweden)

    Shaoming Pan

    Full Text Available Declustering techniques are widely used in distributed environments to reduce query response time through parallel I/O by splitting large files into several small blocks and then distributing those blocks among multiple storage nodes. Unfortunately, however, many small geospatial image data files cannot be further split for distributed storage. In this paper, we propose a complete theoretical system for the distributed storage of small geospatial image data files based on mining the access patterns of geospatial image data using their historical access log information. First, an algorithm is developed to construct an access correlation matrix based on the analysis of the log information, which reveals the patterns of access to the geospatial image data. Then, a practical heuristic algorithm is developed to determine a reasonable solution based on the access correlation matrix. Finally, a number of comparative experiments are presented, demonstrating that our algorithm displays a higher total parallel access probability than those of other algorithms by approximately 10-15% and that the performance can be further improved by more than 20% by simultaneously applying a copy storage strategy. These experiments show that the algorithm can be applied in distributed environments to help realize parallel I/O and thereby improve system performance.

  15. Distributed Storage Algorithm for Geospatial Image Data Based on Data Access Patterns.

    Science.gov (United States)

    Pan, Shaoming; Li, Yongkai; Xu, Zhengquan; Chong, Yanwen

    2015-01-01

    Declustering techniques are widely used in distributed environments to reduce query response time through parallel I/O by splitting large files into several small blocks and then distributing those blocks among multiple storage nodes. Unfortunately, however, many small geospatial image data files cannot be further split for distributed storage. In this paper, we propose a complete theoretical system for the distributed storage of small geospatial image data files based on mining the access patterns of geospatial image data using their historical access log information. First, an algorithm is developed to construct an access correlation matrix based on the analysis of the log information, which reveals the patterns of access to the geospatial image data. Then, a practical heuristic algorithm is developed to determine a reasonable solution based on the access correlation matrix. Finally, a number of comparative experiments are presented, demonstrating that our algorithm displays a higher total parallel access probability than those of other algorithms by approximately 10-15% and that the performance can be further improved by more than 20% by simultaneously applying a copy storage strategy. These experiments show that the algorithm can be applied in distributed environments to help realize parallel I/O and thereby improve system performance.

  16. Comparison of data file and storage configurations for efficient temporal access of satellite image data

    CSIR Research Space (South Africa)

    Bachoo, A

    2009-01-01

    Full Text Available . Traditional storage formats store such a series of images as a sequence of individual files, with each file internally storing the pixels in their spatial order. Consequently, the construction of a time series profile of a single pixel requires reading from...

  17. Luminescence in medical image science

    Energy Technology Data Exchange (ETDEWEB)

    Kandarakis, I.S., E-mail: kandarakis@teiath.gr

    2016-01-15

    Radiation detection in Medical Imaging is mostly based on the use of luminescent materials (scintillators and phosphors) coupled to optical sensors. Materials are employed in the form of granular screens, structured (needle-like) crystals and single crystal transparent blocks. Storage phosphors are also incorporated in some x-ray imaging plates. Description of detector performance is currently based on quality metrics, such as the Luminescence efficiency, the Modulation Transfer Function (MTF), the Noise Power Spectrum (NPS) and the Detective Quantum Efficiency (DQE) can be defined and evaluated. The aforementioned metrics are experimental evaluated for various materials in the form of screens. A software was designed (MINORE v1) to present image quality measurements in a graphical user interface (GUI) environment. Luminescence efficiency, signal and noise analysis are valuable tools for the evaluation of luminescent materials as candidates for medical imaging detectors. - Highlights: • Luminescence based medical imaging detectors. • Image science: MTF, NPS, DQE. • Phosphors screens light emission efficiency experimental evaluation. • Theoretical models for estimation of phosphor screen properties. • Software for medical image quality metrics.

  18. Determination of the size of an imaging data storage device at a full PACS hospital

    International Nuclear Information System (INIS)

    Cha, S. J.; Kim, Y. H.; Hur, G.

    2000-01-01

    To determine the appropriate size of a short and long-term storage device, bearing in mind the design factors involved and the installation costs. The number of radiologic studies quoted is the number of these undertaken during a one-year period at a university hospital with 650 beds, and reflects the actual number of each type of examination performed at a full PACS hospital. The average daily number of outpatients was 1586, while that of inpatients was 639.5. The numbers of radiologic studies performed were as follows : 378 among 189 outpatients, and 165 among 41 inpatients. The average daily number of examinations was 543, comprising 460 CR, 30 ultrasonograms, 25 CT, 8 MRI, 20 others. The total amount of digital images was 17.4 GB per day, while the amount of short-term data with lossless compression was 6.7 GB per day. During 14 days short-term storage, the amount of image data was 93.7 GB in disk array. The amount of data stored mid term (1 year), with lossy compression, was 369.1 GB. The amount of data stored in the form of long-term cache and educational images was 38.7 GB and 30 GB, respectively, The total size of disk array was 531.5 GB. A device suitable for the long-term storage of images, for at least five years, requires a capacity of 1845.5 GB. At a full PACS hospital with 600 beds, the minimum disk space required for the short-and mid-term storage of image data in disk array is 540 GB. The capacity required for long term storage (at least five years) is 1900 GB. (author)

  19. Image storage, cataloguing and retrieval using a personal computer database software application

    International Nuclear Information System (INIS)

    Lewis, G.; Howman-Giles, R.

    1999-01-01

    Full text: Interesting images and cases are collected and collated by most nuclear medicine practitioners throughout the world. Changing imaging technology has altered the way in which images may be presented and are reported, with less reliance on 'hard copy' for both reporting and archiving purposes. Digital image generation and storage is rapidly replacing film in both radiological and nuclear medicine practice. A personal computer database based interesting case filing system is described and demonstrated. The digital image storage format allows instant access to both case information (e.g. history and examination, scan report or teaching point) and the relevant images. The database design allows rapid selection of cases and images appropriate to a particular diagnosis, scan type, age or other search criteria. Correlative X-ray, CT, MRI and ultrasound images can also be stored and accessed. The application is in use at The New Children's Hospital as an aid to postgraduate medical education, with new cases being regularly added to the database

  20. Integral Images: Efficient Algorithms for Their Computation and Storage in Resource-Constrained Embedded Vision Systems.

    Science.gov (United States)

    Ehsan, Shoaib; Clark, Adrian F; Naveed ur Rehman; McDonald-Maier, Klaus D

    2015-07-10

    The integral image, an intermediate image representation, has found extensive use in multi-scale local feature detection algorithms, such as Speeded-Up Robust Features (SURF), allowing fast computation of rectangular features at constant speed, independent of filter size. For resource-constrained real-time embedded vision systems, computation and storage of integral image presents several design challenges due to strict timing and hardware limitations. Although calculation of the integral image only consists of simple addition operations, the total number of operations is large owing to the generally large size of image data. Recursive equations allow substantial decrease in the number of operations but require calculation in a serial fashion. This paper presents two new hardware algorithms that are based on the decomposition of these recursive equations, allowing calculation of up to four integral image values in a row-parallel way without significantly increasing the number of operations. An efficient design strategy is also proposed for a parallel integral image computation unit to reduce the size of the required internal memory (nearly 35% for common HD video). Addressing the storage problem of integral image in embedded vision systems, the paper presents two algorithms which allow substantial decrease (at least 44.44%) in the memory requirements. Finally, the paper provides a case study that highlights the utility of the proposed architectures in embedded vision systems.

  1. Integral Images: Efficient Algorithms for Their Computation and Storage in Resource-Constrained Embedded Vision Systems

    Directory of Open Access Journals (Sweden)

    Shoaib Ehsan

    2015-07-01

    Full Text Available The integral image, an intermediate image representation, has found extensive use in multi-scale local feature detection algorithms, such as Speeded-Up Robust Features (SURF, allowing fast computation of rectangular features at constant speed, independent of filter size. For resource-constrained real-time embedded vision systems, computation and storage of integral image presents several design challenges due to strict timing and hardware limitations. Although calculation of the integral image only consists of simple addition operations, the total number of operations is large owing to the generally large size of image data. Recursive equations allow substantial decrease in the number of operations but require calculation in a serial fashion. This paper presents two new hardware algorithms that are based on the decomposition of these recursive equations, allowing calculation of up to four integral image values in a row-parallel way without significantly increasing the number of operations. An efficient design strategy is also proposed for a parallel integral image computation unit to reduce the size of the required internal memory (nearly 35% for common HD video. Addressing the storage problem of integral image in embedded vision systems, the paper presents two algorithms which allow substantial decrease (at least 44.44% in the memory requirements. Finally, the paper provides a case study that highlights the utility of the proposed architectures in embedded vision systems.

  2. Magnetic resonance imaging findings of central nervous system in lysosomal storage diseases: A pictorial review.

    Science.gov (United States)

    Fagan, Nathan; Alexander, Allen; Irani, Neville; Saade, Charbel; Naffaa, Lena

    2017-06-01

    Lysosomal storage diseases (LSD) are a complex group of genetic disorders that are a result of inborn errors of metabolism. These errors result in a variety of metabolic dysfunction and build-up certain molecules within the tissues of the central nervous system (CNS). Although, they have discrete enzymatic deficiencies, symptomology and CNS imaging findings can overlap with each other, which can become challenging to radiologists. The purpose of this paper is to review the most common CNS imaging findings in LSD in order to familiarize the radiologist with their imaging findings and help narrow down the differential diagnosis. © 2016 The Royal Australian and New Zealand College of Radiologists.

  3. Applying x-ray digital imaging to the verification of cadmium in fuel-storage components

    International Nuclear Information System (INIS)

    Dabbs, R.D.; Cook, D.H.

    1997-01-01

    The High Flux Isotope Reactor utilizes large underwater fuel-storage arrays to stage irradiated fuel before it is shipped from the facility. Cadmium is required as a thermal neutron absorber in these fuel-storage arrays to produce an acceptable margin of nuclear subcriticality during both normal and off-normal operating conditions. Due to incomplete documentation from the time of their fabrication, the presence of cadmium within two stainless-steel parts of fuel-storage arrays must be experimentally verified before they are reused in new fuel-storage arrays. A cadmium-verification program has been developed in association with the Waste Examination and Assay Facility located at the Oak Ridge national Laboratory to nondestructively examine these older shroud assemblies. The program includes the following elements (1) x-ray analog imaging, (2) x-ray digital imaging, (3) prompt-gamma-ray spectroscopy measurements, and (4) neutron-transmission measurements. X-ray digital imaging utilizes an analog-to-digital convertor to record attenuated x-ray intensities observed on a fluorescent detector by a video camera. These x-ray intensities are utilized in expressions for cadmium thickness based upon x-ray attenuation theory

  4. Using Object Storage Technology vs Vendor Neutral Archives for an Image Data Repository Infrastructure.

    Science.gov (United States)

    Bialecki, Brian; Park, James; Tilkin, Mike

    2016-08-01

    The intent of this project was to use object storage and its database, which has the ability to add custom extensible metadata to an imaging object being stored within the system, to harness the power of its search capabilities, and to close the technology gap that healthcare faces. This creates a non-disruptive tool that can be used natively by both legacy systems and the healthcare systems of today which leverage more advanced storage technologies. The base infrastructure can be populated alongside current workflows without any interruption to the delivery of services. In certain use cases, this technology can be seen as a true alternative to the VNA (Vendor Neutral Archive) systems implemented by healthcare today. The scalability, security, and ability to process complex objects makes this more than just storage for image data and a commodity to be consumed by PACS (Picture Archiving and Communication System) and workstations. Object storage is a smart technology that can be leveraged to create vendor independence, standards compliance, and a data repository that can be mined for truly relevant content by adding additional context to search capabilities. This functionality can lead to efficiencies in workflow and a wealth of minable data to improve outcomes into the future.

  5. Final Technical Report: Imaging a Dry Storage Cask with Cosmic Ray Muons

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Haori; Hayward, Jason; Can, Liao; Liu, Zhengzhi

    2018-03-31

    The goal of this project is to build a scaled prototype system for monitoring used nuclear fuel (UNF) dry storage casks (DSCs) through cosmic ray muon imaging. Such a system will have the capability of verifying the content inside a DSC without opening it. Because of the growth of the nuclear power industry in the U.S. and the policy decision to ban reprocessing of commercial UNF, the used fuel inventory at commercial reactor sites has been increasing. Currently, UNF needs to be moved to independent spent fuel storage installations (ISFSIs), as its inventory approaches the limit on capacity of on-site wet storage. Thereafter, the fuel will be placed in shipping containers to be transferred to a final disposal site. The ISFSIs were initially licensed as temporary facilities for ~20-yr periods. Given the cancellation of the Yucca mountain project and no clear path forward, extended dry-cask storage (~100 yr.) at ISFSIs is very likely. From the point of view of nuclear material protection, accountability and control technologies (MPACT) campaign, it is important to ensure that special nuclear material (SNM) in UNF is not stolen or diverted from civilian facilities for other use during the extended storage.

  6. Characterization of water distribution in bread during storage using magnetic resonance imaging.

    Science.gov (United States)

    Lodi, Alessia; Abduljalil, Amir M; Vodovotz, Yael

    2007-12-01

    A soy bread of fully acceptable quality and containing 49% soy ingredients (with or without 5% almond powder) has been recently developed in our laboratory. An investigation on water distribution and mobility, as probed by proton signal intensity and T2 magnetic resonance images, during storage was designed to examine possible relations between water states and hindered staling rate upon soy or soy-almond addition. Water proton distribution throughout soy-containing loaves was found to be very homogeneous in fresh breads with and without almond, with minimal water migration occurring during prolonged storage. In contrast, traditional wheat bread displayed an inhomogeneous water proton population that tended to change (with higher moisture migration towards the outer perimeter of the slice) during storage. Similar results were found for water mobility throughout the loaves, as depicted in T2 images. On intensity images of all considered bread varieties, the outer perimeter corresponding to the crust exhibited lower signal intensity due to decreased water content. Higher T2 values were found in the crust of soy breads with and without almond, which were attributed to lipids. The results indicated that the addition of soy to bread improved the homogeneous distribution of water molecules, which may hinder the staling rate of soy-containing breads. However, incorporation of almond had little effect on the water proton distribution or mobility of soy breads.

  7. Acoustic imaging of underground storage tank wastes: A feasibility study. Final report

    International Nuclear Information System (INIS)

    Turpening, R.; Zhu, Z.; Caravana, C.; Matarese, J.

    1995-01-01

    The objectives for this underground storage tank (UST) imaging investigation are: (1) to assess the feasibility of using acoustic methods in UST wastes, if shown to be feasible, develop and assess imaging strategies; (2) to assess the validity of using chemical simulants for the development of acoustic methods and equipment. This investigation examined the velocity of surrogates, both salt cake and sludge surrogates. In addition collected seismic cross well data in a real tank (114-TX) on the Hanford Reservation. Lastly, drawing on the knowledge of the simulants and the estimates of the velocities of the waste in tank 114-TX the authors generated a hypothetical model of waste in a tank and showed that non-linear travel time tomographic imaging would faithfully image that stratigraphy

  8. A storage and display method for radioisotope imaging using scan conversion memory

    International Nuclear Information System (INIS)

    Takizawa, Masaomi; Kobayashi, Toshio; Nakanishi, Fumiko; Suzuki, Shigeo; Miyabayashi, Hiroyasu

    1975-01-01

    The scan conversion memory (SCM) has been applied to a method for the storage and display of radioisotope images. Scan data were fed into SCM as pulse signals with X and Y axis from the scinti-scanner or the scinti-camera. The electric charge on the SCM target is directly proportional to the pulse density. A TV display was executed immediately after the recording of a radioisotope image. If necessary, a seven additive color display to the image density could be obtained by a simple color slicer, and the image could be hard-copied by a video hard-copy printer. Characteristics of the SCM were experimentally clarified as follows: the practical resolution was 700 line/TV; ten levels gray scale were discriminated on the video monitor, the uniformity, measured by an oscilloscope was less than 20%, and dead time of the pulse interval at full scale signal was 5 μ sec. In their representation, the SCM scintigrams were observed as closely resembling conventional film scintigrams. Superimposed imaging of an X-ray picture and a radioisotope image can be realized by using the SCM, for an increase in anatomical localization on reading images. The SCM scintigram can be applied rapidly and can be the viewer of radioisotope imaging. (auth.)

  9. Army medical imaging system: ARMIS

    International Nuclear Information System (INIS)

    Siedband, M.P.; Kramp, D.C.

    1987-01-01

    Recent advances of stimulable phosphor screens, data cards using optical storage means, and new personal computers with image processing capability have made possible the design of economical filmless medical imaging systems. The addition of communication links means that remote interpretation of images is also possible. The Army Medical Imaging System uses stimulable phosphor screens, digital readout, a small computer, an optical digital data card device, and a DIN/PACS link. Up to 200 images can be stored in the computer hard disk for rapid recall and reading by the radiologist. The computer permits image processing, annotation, insertion of text, and control of the system. Each device contains an image storage RAM and communicates with the computer via the small computer systems interface. Data compression is used to reduce the required storage capacity and transmission times of the 1-mB images. The credit card-size optical data cards replace film and can store 12 or more images. The data cards can be read on an independent viewer. The research is supported by the U.S. Army Biomedical Research and Development Laboratory

  10. Effects of imaging gradients in sequences with varying longitudinal storage time-Case of diffusion exchange imaging.

    Science.gov (United States)

    Lasič, Samo; Lundell, Henrik; Topgaard, Daniel; Dyrby, Tim B

    2018-04-01

    To illustrate the potential bias caused by imaging gradients in correlation MRI sequences using longitudinal magnetization storage (LS) and examine the case of filter exchange imaging (FEXI) yielding maps of the apparent exchange rate (AXR). The effects of imaging gradients in FEXI were observed on yeast cells. To analyze the AXR bias, signal evolution was calculated by applying matrix exponential operators. A sharp threshold for the slice thickness was identified, below which the AXR is increasingly underestimated. The bias can be understood in terms of an extended low-pass diffusion filtering during the LS interval, which is more pronounced at lower exchange rates. For a total exchange rate constant larger than 1 s -1 , the AXR bias is expected to be negligible when slices thicker than 2.5 mm are used. In correlation experiments like FEXI, relying on LS with variable duration, imaging gradients may cause disrupting effects that cannot be easily mitigated and should be carefully considered for unbiased results. In typical clinical applications of FEXI, the imaging gradients are expected to cause a negligible AXR bias. However, the AXR bias may be significant in preclinical settings or whenever thin imaging slices are used. Magn Reson Med 79:2228-2235, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Recovering uranium from phosphoric acid

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Wet-process phosphoric acid contains a significant amount of uranium. This uranium totals more than 1,500 tons/yr in current U.S. acid output--and projections put the uranium level at 8,000 tons/yr in the year 2000. Since the phosphoric acid is a major raw material for fertilizers, uranium finds its way into those products and is effectively lost as a resource, while adding to the amount of radioactive material that can contaminate the food chain. So, resource-conservation and environmental considerations both make recovery of the uranium from phosphoric acid desirable. This paper describes the newly developed process for recovering uranium from phosphoric acid by using solvent-extraction technique. After many extractants had been tested, the researchers eventually selected the combination of di (2-ethylhexyl) phosphoric acid (DEPA) and trioctylphosphine oxide (TOPO) as the most suitable. The flowscheme of the process is included

  12. Opposed-phase MR imaging of lipid storage myopathy in a case of Chanarin-Dorfman disease

    International Nuclear Information System (INIS)

    Gaeta, Michele; Celona, Antonio; Racchiusa, Sergio; Mazziotti, Silvio; Minutoli, Fabio; Toscano, Antonio; Musumeci, Olimpia

    2008-01-01

    Chanarin-Dorfman disease (CDD) is a rare genetic disorder characterized by ichthyosis, myopathy, central nervous system disturbances, and intracellular lipid storage in muscle fibers, hepatocytes, and granulocytes. We describe skeletal muscle magnetic resonance imaging findings in a case of CDD, outlining the potential role of GE T1-weighted opposed-phase sequence (chemical shift imaging) in the evaluation of lipid storage myopathies. (orig.)

  13. Opposed-phase MR imaging of lipid storage myopathy in a case of Chanarin-Dorfman disease

    Energy Technology Data Exchange (ETDEWEB)

    Gaeta, Michele; Celona, Antonio; Racchiusa, Sergio; Mazziotti, Silvio [University of Messina, Department of Radiological Sciences, Messina (Italy); Minutoli, Fabio [University of Messina, Department of Radiological Sciences, Messina (Italy); A.O.U. ' ' Policlinico G. Martino' ' , Dipartimento di Scienze Radiologiche, Messina (Italy); Toscano, Antonio; Musumeci, Olimpia [University of Messina, Department of Neurosciences, Psychiatry and Anaesthesiology, Messina (Italy)

    2008-11-15

    Chanarin-Dorfman disease (CDD) is a rare genetic disorder characterized by ichthyosis, myopathy, central nervous system disturbances, and intracellular lipid storage in muscle fibers, hepatocytes, and granulocytes. We describe skeletal muscle magnetic resonance imaging findings in a case of CDD, outlining the potential role of GE T1-weighted opposed-phase sequence (chemical shift imaging) in the evaluation of lipid storage myopathies. (orig.)

  14. Uranium extraction from phosphoric acid

    International Nuclear Information System (INIS)

    Lounis, A.

    1983-05-01

    A study has been carried out for the extraction of uranium from phosphoric acid produced in Algeria. First of all, the Algerian phosphoric acid produced in Algeria by SONATRACH has been characterised. This study helped us to synthesize a phosphoric acid that enabled us to pass from laboratory tests to pilot scale tests. We have then examined extraction and stripping parameters: diluent, DZEPHA/TOPO ratio and oxidising agent. The laboratory experiments enabled us to set the optimum condition for the choice of diluent, extractant concentration, ratio of the synergic mixture, oxidant concentration, redox potential. The equilibrium isotherms lead to the determination of the number of theoretical stages for the uranium extraction and stripping of uranium, then the extraction from phosphoric acid has been verified on a pilot scale (using a mixer-settler)

  15. Uranium extraction from phosphoric acid

    International Nuclear Information System (INIS)

    Araujo Figueiredo, C. de

    1984-01-01

    The recovery of uranium from phosphoric liquor by two extraction process is studied. First, uranium is reduced to tetravalent condition and is extracted by dioctypyrophosphoric acid. The re-extraction is made by concentrated phosphoric acid with an oxidizing agent. The re-extract is submitted to the second process and uranium is extracted by di-ethylhexilphosphoric acid and trioctylphosphine oxide. (M.A.C.) [pt

  16. Electron-beam-pumped phosphors

    International Nuclear Information System (INIS)

    Goldhar, J.; Krupke, W.F.

    1985-01-01

    Electron-beam excitation of solid-state scintillators, or phosphors, can result in efficient generation of visible light confined to relatively narrow regions of the spectrum. The conversion efficiency can exceed 20%, and, with proper choice of phosphors, radiation can be obtained anywhere from the near infrared (IR) to the near ultraviolet (UV). These properties qualify the phosphors as a potentially useful pump source for new solid-state lasers. New phosphors are being developed for high-brightness television tubes that are capable of higher power dissipation. Here, an epitaxial film of fluorescing material is grown on a crystalline substrate with good thermal properties. For example, researchers at North American Philips Laboratories have developed a cerium-doped yttrium aluminum garnet (YAG) grown on a YAG substrate, which has operated at 1 A/cm 2 at 20 kV without observed thermal quenching. The input power is higher by almost two orders of magnitude than that which can be tolerated by a conventional television phosphor. The authors describe tests of these new phosphors

  17. Simultaneous storage of medical images in the spatial and frequency domain: A comparative study

    Directory of Open Access Journals (Sweden)

    Acharya U Rajendra

    2004-06-01

    Full Text Available Abstract Background Digital watermarking is a technique of hiding specific identification data for copyright authentication. This technique is adapted here for interleaving patient information with medical images, to reduce storage and transmission overheads. Methods The patient information is encrypted before interleaving with images to ensure greater security. The bio-signals are compressed and subsequently interleaved with the image. This interleaving is carried out in the spatial domain and Frequency domain. The performance of interleaving in the spatial, Discrete Fourier Transform (DFT, Discrete Cosine Transform (DCT and Discrete Wavelet Transform (DWT coefficients is studied. Differential pulse code modulation (DPCM is employed for data compression as well as encryption and results are tabulated for a specific example. Results It can be seen from results, the process does not affect the picture quality. This is attributed to the fact that the change in LSB of a pixel changes its brightness by 1 part in 256. Spatial and DFT domain interleaving gave very less %NRMSE as compared to DCT and DWT domain. Conclusion The Results show that spatial domain the interleaving, the %NRMSE was less than 0.25% for 8-bit encoded pixel intensity. Among the frequency domain interleaving methods, DFT was found to be very efficient.

  18. Power budget analysis of image-plane storage in spectral hole-burning materials

    International Nuclear Information System (INIS)

    Neifeld, M.A.; Randall Babbitt, W.; Krishna Mohan, R.; Craig, A.E.

    2004-01-01

    We analyze the power requirements of a volumetric storage system based on hole-burning materials. We consider an image-plane architecture that uses ultra-fine wavelength addressing. We perform an optimization study in which hole-depth, material thickness, and spot size are selected to minimize the system power budget. We find that a data rate of 10 Gbps and a latency of 10 μs can be achieved in a read-once system based on Eu-YSO with a total power budget of only 23 mW. The same material system designed to tolerate 1000 read cycles would require only a factor of 15 increase in power

  19. Pocket Size Solid State FLASH and iPOD Drives for gigabyte storage, display and transfer of digital medical images: an introduction

    International Nuclear Information System (INIS)

    Sankaran, A.

    2008-01-01

    The transition of radiological imaging from analog to digital was closely followed by the development of the Picture Archiving and Communication (PACS) system. Concomitantly, multidimensional imaging ( 4D and 5D, for motion and functional studies on 3D images) have presented new challenges, particularly in handling gigabyte size images from CT, MRI and PET scanners, which generate thousands of images. The storage and analysis of these images necessitate expensive image workstations. This paper highlights the recent innovations in mass storage, display and transfer of images, using miniature/pocket size solid state FLASH and iPOD drives

  20. Water level response measurement in a steel cylindrical liquid storage tank using image filter processing under seismic excitation

    Science.gov (United States)

    Kim, Sung-Wan; Choi, Hyoung-Suk; Park, Dong-Uk; Baek, Eun-Rim; Kim, Jae-Min

    2018-02-01

    Sloshing refers to the movement of fluid that occurs when the kinetic energy of various storage tanks containing fluid (e.g., excitation and vibration) is continuously applied to the fluid inside the tanks. As the movement induced by an external force gets closer to the resonance frequency of the fluid, the effect of sloshing increases, and this can lead to a serious problem with the structural stability of the system. Thus, it is important to accurately understand the physics of sloshing, and to effectively suppress and reduce the sloshing. Also, a method for the economical measurement of the water level response of a liquid storage tank is needed for the exact analysis of sloshing. In this study, a method using images was employed among the methods for measuring the water level response of a liquid storage tank, and the water level response was measured using an image filter processing algorithm for the reduction of the noise of the fluid induced by light, and for the sharpening of the structure installed at the liquid storage tank. A shaking table test was performed to verify the validity of the method of measuring the water level response of a liquid storage tank using images, and the result was analyzed and compared with the response measured using a water level gauge.

  1. Contrast and decay of cathodoluminescence from phosphor particles in a scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Engelsen, Daniel den; Harris, Paul G.; Ireland, Terry G., E-mail: terry.ireland@brunel.ac.uk; Fern, George R.; Silver, Jack

    2015-10-15

    Cathodoluminescence (CL) studies are reported on phosphors in a field emission scanning electron microscope (FESEM). ZnO: Zn and other luminescent powders manifest a bright ring around the periphery of the particles: this ring enhances the contrast. Additionally, particles resting on top of others are substantially brighter than underlying ones. These phenomena are explained in terms of the combined effects of electrons backscattered out of the particles, together with light absorption by the substrate. The contrast is found to be a function of the particle size and the energy of the primary electrons. Some phosphor materials exhibit a pronounced comet-like structure at high scan rates in a CL-image, because the particle continues to emit light after the electron beam has moved to a position without phosphor material. Image analysis has been used to study the loss of brightness along the tail and hence to determine the decay time of the materials. The effect of phosphor saturation on the determination of decay times by CL-microscopy was also investigated. - Highlights: • Contrast enhancement are observed in secondary electron and cathodoluminescent images of phosphor particles sitting on top of others. • Backscattered electrons largely explain the observed contrast enhancement. • After glow effects in CL-micrographs of phosphors enable the determination of decay times. • Phosphor saturation can be used to determine the decay time of individual spectral transitions.

  2. Holographic storage of three-dimensional image and data using photopolymer and polymer dispersed liquid crystal films

    International Nuclear Information System (INIS)

    Gao Hong-Yue; Liu Pan; Zeng Chao; Yao Qiu-Xiang; Zheng Zhiqiang; Liu Jicheng; Zheng Huadong; Yu Ying-Jie; Zeng Zhen-Xiang; Sun Tao

    2016-01-01

    We present holographic storage of three-dimensional (3D) images and data in a photopolymer film without any applied electric field. Its absorption and diffraction efficiency are measured, and reflective analog hologram of real object and image of digital information are recorded in the films. The photopolymer is compared with polymer dispersed liquid crystals as holographic materials. Besides holographic diffraction efficiency of the former is little lower than that of the latter, this work demonstrates that the photopolymer is more suitable for analog hologram and big data permanent storage because of its high definition and no need of high voltage electric field. Therefore, our study proposes a potential holographic storage material to apply in large size static 3D holographic displays, including analog hologram displays, digital hologram prints, and holographic disks. (special topic)

  3. 21 CFR 182.1073 - Phosphoric acid.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Phosphoric acid. 182.1073 Section 182.1073 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN....1073 Phosphoric acid. (a) Product. Phosphoric acid. (b) Conditions of use. This substance is generally...

  4. 21 CFR 582.1073 - Phosphoric acid.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Phosphoric acid. 582.1073 Section 582.1073 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Additives § 582.1073 Phosphoric acid. (a) Product. Phosphoric acid. (b) Conditions of use. This substance is...

  5. Computed and conventional chest radiography: a comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Ramli, K.; Abdullah, B.J.J.; Ng, K-H.; Hussain, A.F.; Mahmud, R.

    2005-01-01

    The aim of this study was to compare the image quality and entrance skin dose (ESD) for film-screen and computed chest radiography. Analysis of the image quality and dose on chest radiography was carried out on a conventional X-ray unit using film-screen, storage phosphor plates and selenium drum direct chest radiography. For each receptor, ESD was measured in 60 patients using thermoluminescent dosemeters. Images were printed on 35 x 43 cm films. Image quality was assessed subjectively by evaluation of anatomic features and estimation of the image quality, following the guidelines established by the protocols of the Commission of the European Communities. There was no statistically significant difference noted between the computed and conventional images (Wilcoxon rank sum test, P>0.05). Imaging of the mediastinum and peripheral lung structures were better visualized with the storage phosphor and selenium drum technique than with the film-screen combination. The patients' mean ESD for chest radiography using the storage phosphor, film-screen combination and selenium drum was 0.20, 0.20 and 0.25 mGy, respectively, with no statistically significant difference with P > 0.05 (χ 2 tests) Copyright (2005) Blackwell Publishing Asia Pty Ltd

  6. Recovering uranium from phosphoric acid

    International Nuclear Information System (INIS)

    Abodishish, H.A.; Ritchey, R.W.

    1982-01-01

    Precipitation of Fe 3 HN 4 H 8 (PO 4 ) 6 is prevented in the second cycle extractor, in a two cycle uranium recovery process, by washing ammonia laden organic solvent stream, from the second cycle stripper, with first cycle raffinate iron stream containing phosphoric acid, prior to passing the solvent stream into the second cycle extractor. (author)

  7. Influence of Bias on the Friction Imaging of Ferroelectric Domains in Single Crystal Barium Titanate Energy Storage Materials

    Directory of Open Access Journals (Sweden)

    Lan Chen

    2014-01-01

    Full Text Available The friction imaging of newlycleaved surface domains of single crystal BaTiO3 energy storage materials under both positive and negative voltage bias is investigated by scanning force microscope. When the bias was applied and reversed, three regions with different brightness and contrast in friction image indicated different response to the biases: the friction image of domain A displayed a great change in brightness while domains B and C displayed only a very small change. Possible mechanisms of the interesting phenomena originating from different static force between different charged tip and the periodical array of surface charges inside the inplane domains were proposed. These results provide a new method for the determination of the polarization direction for the domain parallel to the surface and may be useful in the investigation of ferroelectric energy storage materials, especially the relationship between the polarization direction of domain and the bias.

  8. Application of strong phosphoric acid to radiochemistry

    International Nuclear Information System (INIS)

    Terada, Kikuo

    1977-01-01

    Not only inorganic and organic compounds but also natural substrances, such as accumulations in soil, are completely decomposed and distilled by heating with strong phosphoric acid for 30 to 50 minutes. As applications of strong phosphoric acid to radiochemistry, determination of uranium and boron by use of solubilization effect of this substance, titration of uranyl ion by use of sulfuric iron (II) contained in this substance, application to tracer experiment, and determination of radioactive ruthenium in environmental samples are reviewed. Strong phosphoric acid is also applied to activation analysis, for example, determination of N in pyrographite with iodate potassium-strong phosphoric acid method, separation of Os and Ru with sulfuric cerium (IV) - strong phosphoric acid method or potassium dechromate-strong phosphoric acid method, analysis of Se, As and Sb rocks and accumulations with ammonium bromide, sodium chloride and sodium bromide-strong phosphoric acid method. (Kanao, N.)

  9. Efficiency of Lu2SiO5:Ce (LSO) powder phosphor as X-ray to light converter under mammographic imaging conditions

    International Nuclear Information System (INIS)

    David, S.; Michail, C.; Valais, I.; Nikolopoulos, D.; Liaparinos, P.; Kalivas, N.; Kalatzis, I.; Toutountzis, A.; Efthimiou, N.; Loudos, G.; Sianoudis, I.; Cavouras, D.; Dimitropoulos, N.; Nomicos, C.D.; Kandarakis, I.; Panayiotakis, G.S.

    2007-01-01

    The aim of the present study was to examine the light emission efficiency of Lu 2 SiO 5 :Ce (LSO) powder scintillator under X-ray mammographic imaging conditions. Powder LSO scintillator has never been used in X-ray imaging. For the purposes of the present study, a 25 mg/cm 2 thick scintillating screen was prepared in our laboratory, by sedimentation of Lu 2 SiO 5 :Ce powder. Absolute luminescence efficiency measurements were performed within the range of X-ray tube voltages (22-49 kVp) used in mammographic applications. Parameters related to X-ray detection, i.e. the energy absorption efficiency (EAE) and the quantum detection efficiency (QDE) were calculated. A theoretical model, describing radiation and light transfer, was employed to fit experimental data and to estimate values of the intrinsic conversion efficiency and the light attenuation coefficients of the screen. The spectral compatibility of the LSO powder scintillator to mammographic X-ray films and to various electronic optical detectors was determined by performing light emission spectrum measurements and by taking into account the spectral sensitivity of the optical detectors. Results in the voltage range used in mammography showed that Lu 2 SiO 5 :Ce powder scintillator has approximately 10% higher values of QDE and 4.5% higher values of EAE than Gd 2 O 2 S:Tb

  10. Ion-implanted PLZT ceramics: a new high-sensitivity image storage medium

    International Nuclear Information System (INIS)

    Peercy, P.S.; Land, C.E.

    1980-01-01

    Results were presented of our studies of photoferroelectric (PFE) image storage in H- and He-ion implanted PLZT (lead lanthanum zirconate titanate) ceramics which demonstrate that the photosensitivity of PLZT can be significantly increased by ion implantation in the ceramic surface to be exposed to image light. More recently, implantations of Ar and Ar + Ne into the PLZT surface have produced much greater photosensitivity enhancement. For example, the photosensitivity after implantation with 1.5 x 10 14 350 keV Ar/cm 2 + 1 x 10 15 500 keV Ne/cm 2 is increased by about four orders of magnitude over that of unimplanted PLZT. Measurements indicate that the photosensitivity enhancement in ion-implanted PLZT is controlled by implantation-produced disorder which results in marked decreases in dielectric constant and dark conductivity and changes in photoconductivity of the implanted layer. The effects of Ar- and Ar + Ne-implantation are presented along with a phenomenological model which describes the enhancement in photosensitivity obtained by ion implantation. This model takes into account both light- and implantation-induced changes in conductivity and gives quantitative agreement with the measured changes in the coercive voltage V/sub c/ as a function of near-uv light intensity for both unimplanted and implanted PLZT. The model, used in conjunction with calculations of the profiles of implantation-produced disorder, has provided the information needed for co-implanting ions of different masses, e.g., Ar and Ne, to improve photosensitivity

  11. Radioluminescent nuclear batteries with different phosphor layers

    International Nuclear Information System (INIS)

    Hong, Liang; Tang, Xiao-Bin; Xu, Zhi-Heng; Liu, Yun-Peng; Chen, Da

    2014-01-01

    Highlights: • We present and test the electrical properties of the nuclear battery. • The best thickness range for ZnS:Cu phosphor layer is 12–14 mg cm −2 for 147 Pm radioisotope. • The best thickness range for Y 2 O 2 S:Eu phosphor layer is 17–21 mg cm −2147 Pm radioisotope. • The battery with ZnS:Cu phosphor layer can provide higher energy conversion efficiency. • The mechanism affecting the nuclear battery output performance is revealed. - Abstract: A radioluminescent nuclear battery based on the beta radioluminescence of phosphors is presented, and which consists of 147 Pm radioisotope, phosphor layers, and GaAs photovoltaic cell. ZnS:Cu and Y 2 O 2 S:Eu phosphor layers for various thickness were fabricated. To investigate the effect of phosphor layer parameters on the battery, the electrical properties were measured. Results indicate that the optimal thickness ranges for the ZnS:Cu and Y 2 O 2 S:Eu phosphor layers are 12 mg cm −2 to 14 mg cm −2 and 17 mg cm −2 to 21 mg cm −2 , respectively. ZnS:Cu phosphor layer exhibits higher fluorescence efficiency compared with the Y 2 O 2 S:Eu phosphor layer. Its spectrum properly matches the spectral response of GaAs photovoltaic cell. As a result, the battery with ZnS:Cu phosphor layer indicates higher energy conversion efficiency than that with Y 2 O 2 S:Eu phosphor layer. Additionally, the mechanism of the phosphor layer parameters that influence the output performance of the battery is discussed through the Monte Carlo method and transmissivity test

  12. Phosphorous loads evaluation from soil

    International Nuclear Information System (INIS)

    Mezzanotte, V.

    1996-01-01

    With reference to the well known difficulty of quantifying non point phosphorous loads, as well as to their growing relative importance where point source leads decrease, a literature review has been carried out concerning soil export coefficients. On such basis, the values which seem to be the most appropriate for Italy have been estimated for different land use categories. The main mechanisms determining non point phosphorous load generation and the factors affecting their importance are also described. In the end, criteria for estimating the importance of non point sources in a basin are suggested to be used for deciding whether a traditional, parametric assessment (inevitably involving a certain error) can be acceptable or experimental measures are needed

  13. Uranium extraction in phosphoric acid

    International Nuclear Information System (INIS)

    Araujo Figueiredo, C. de

    1984-01-01

    Uranium is recovered from the phosphoric liquor produced from the concentrate obtained from phosphorus-uraniferous mineral from Itataia mines (CE, Brazil). The proposed process consists of two extraction cycles. In the first one, uranium is reduced to its tetravalent state and then extracted by dioctylpyrophosphoric acid, diluted in Kerosene. Re-extraction is carried out with concentrated phosphoric acid containing an oxidising agent to convert uranium to its hexavalent state. This extract (from the first cycle) is submitted to the second cycle where uranium is extracted with DEPA-TOPO (di-2-hexylphosphoric acid/tri-n-octyl phosphine oxide) in Kerosene. The extract is then washed and uranium is backextracted and precipitated as commercial concentrate. The organic phase is recovered. Results from discontinuous tests were satisfactory, enabling to establish operational conditions for the performance of a continuous test in a micro-pilot plant. (Author) [pt

  14. Luminescence studies on phosphor screens

    International Nuclear Information System (INIS)

    Panayiotakis, G.; Nomikos, C.; Bakas, A.; Proimos, B.

    1994-01-01

    We report our results on x-ray phosphor screens prepared of some new materials focusing attention on their efficiency under fluoroscopy conditions, on optimization conditions and on comparisons among the various materials. All data are presented in absolute values. A theoretical model is presented, that takes into account the granular structure of the screens, permitting the explanation and prediction of the luminescence properties of the screens. (authors)

  15. Luminescence studies on phosphor screens

    Energy Technology Data Exchange (ETDEWEB)

    Panayiotakis, G; Nomikos, C; Bakas, A; Proimos, B [Medical Physics Department, University of Patras, 265 00 Patras, Greece (Greece)

    1994-12-31

    We report our results on x-ray phosphor screens prepared of some new materials focusing attention on their efficiency under fluoroscopy conditions, on optimization conditions and on comparisons among the various materials. All data are presented in absolute values. A theoretical model is presented, that takes into account the granular structure of the screens, permitting the explanation and prediction of the luminescence properties of the screens. (authors). 12 refs, 3 figs.

  16. 31P MR spectroscopic imaging in preoperative embolization therapy of meningiomas; Phosphor-31-MR-spektroskopische Bildgebung bei praeoperativer Embolisationstherapie von Meningeomen

    Energy Technology Data Exchange (ETDEWEB)

    Blankenhorn, M. [Psychiatrische Universitaetsklinik, Ulm (Germany). Abteilung III; Bachert, P.; Kaick, G. van [Deutsches Krebsforschungszentrum Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik; Semmler, W. [Freie Univ. Berlin (Germany). Inst. fuer Diagnostikforschung; Ende, G. [Zentralinstitut fuer Seelische Gesundheit, Mannheim (Germany). NMR-Forschung in der Psychiatrie; Tronnier, V. [Neurochirurgische Klinik, Klinikum der Universitaet, Heidelberg (Germany); Sartor, K. [Neurologische Klinik, Klinikum der Universitaet, Heidelberg (Germany). Abt. Neuroradiologie

    1999-06-01

    Purpose: {sup 31}P MR spectroscopic imaging ({sup 31}P SI) was evaluated in a clinical study as a method for monitoring presurgical devascularization of meningiomas. The aim was to assess noninvasively metabolic alterations in tumor and in healthy brain tissue before and after embolization. Methods: Localized {sup 31}P MR spectra of the brain were obtained by means of 2D-SI (voxel size: 36 cm{sup 3}) using a 1,5-T whole-body MR tomograph. Results: Eleven of 19 patients with intracranial meningiomas examined in this study underwent preoperative embolization therapy; eight patients were examined before and after treatment. After embolization, alterations of pH and of the concentrations of high-energy phosphates (nucleoside-5`triphosphate=NTP, phosphocreatine=PCr), inorganic phosphate (P{sub i}), and membrane constituents were observed in the tumors. A tendency of [P{sub i}] increase and decrease of [NTP], [PCr], and pH predominated, which is explained by ischemic processes after tumor devascularization. Conclusion: {sup 31}P SI is applicable in clinical studies and detects alterations of phosphate metabolism in a meningioma after embolization. (orig.) [Deutsch] Ziel: Die {sup 31}P-MR-spektroskopische Bildgebung ({sup 31}P-SI) wurde im Rahmen der praeoperativen Embolisationstherapie von Patienten mit Meningeomen als Methode zur Therapieverlaufskontrolle klinisch geprueft. Ziel der Studie war die nichtinvasive Erfassung von Veraenderungen im Metabolismus der Tumoren vor und nach Embolisation im Vergleich zum gesunden Hirngewebe. Methoden: Lokalisierte {sup 31}P-MR-Spektren des Gehirns wurden mit 2D-SI (Voxelgroesse: 36 cm{sup 3}) an einem 1,5-T-Ganzkoerper-MR-Tomographen aufgenommen. Ergebnisse: Elf von insgesamt 19 untersuchten Patienten unterzogen sich einer praeoperativen Embolisation, bei acht Patienten konnte eine Verlaufskontrolle durchgefuehrt werden. Nach Embolisation wurden Veraenderungen des pH und der Konzentrationen von energiereichen Phosphaten (Nukleosid

  17. The display of X-ray images

    International Nuclear Information System (INIS)

    1974-01-01

    In order to decrease the radiation doses incurred by radiological investigation of patients, a method is developed to fix an image on a screen in a thermoluminescent phosphor and subsequently heating that phosphor by scanning the screen with a laser

  18. Consumption of Pt anode in phosphoric acid

    Energy Technology Data Exchange (ETDEWEB)

    Kamiya, N.; Urata, K.; Motohira, N.; Ota, K. [Yokohama National University, Yokohama (Japan)

    1997-12-05

    Consumption of Pt anode was investigated in phosphoric acid of various concentration. In 30-70wt% phosphoric acid, Pt dissolved at the rate of 19{mu}gcm{sup -2}h{sup -1}. On the other hand, in 85 wt% phosphoric acid, the amount increased to 0.91 mgcm{sup -2}h{sup -1} which is ca. 180 and 1800 times as much as in 1M sulfuric acid and 1M alkaline solution, respectively. In the diluted phosphoric acid solution, the Pt surface was covered with Pt oxides during the electrolysis, which would prevent the surface from corrosion. However, in the concentrated phosphoric acid, no such oxide surface was observed. Concentrated phosphoric acid might form stable complex with Pt species, therefore the uncovered bare Pt surface is situated in the serious corrosion condition under the high overvoltage and Pt would dissolve into the solution directly instead of forming the Pt oxides. 11 refs., 9 figs., 1 tab.

  19. Method of preparing a thermoluminescent phosphor

    Science.gov (United States)

    Lasky, Jerome B.; Moran, Paul R.

    1979-01-01

    A thermoluminescent phosphor comprising LiF doped with boron and magnesium is produced by diffusion of boron into a conventional LiF phosphor doped with magnesium. Where the boron dopant is made to penetrate only the outer layer of the phosphor, it can be used to detect shallowly penetrating radiation such as tritium beta ays in the presence of a background of more penetrating radiation.

  20. Thermoluminescence properties of Li2B4O7:Cu, B phosphor synthesized using solution combustion technique

    Science.gov (United States)

    Ozdemir, A.; Altunal, V.; Kurt, K.; Depci, T.; Yu, Y.; Lawrence, Y.; Nur, N.; Guckan, V.; Yegingil, Z.

    2017-12-01

    To determine the effects of various concentrations of the activators copper (Cu) and boron (B) on the thermoluminescence (TL) properties of lithium tetraborate, the phosphor was first synthesized and doped with five different concentrations of copper (0.1-0.005 wt%) using solution combustion method. 0.01 wt% Cu was the concentration which showed the most significant increase in the sensitivity of the phosphor. The second sort of Li2B4O7:Cu material was prepared by adding B (0.001-0.03 wt%) to it. The newly developed copper-boron activated lithium tetraborate (Li2B4O7:Cu, B) material with 0.01 wt% Cu and 0.001 wt% B impurity concentrations was shown to have promise as a TL phosphor. The material formation was examined using powder x-Ray Diffraction (XRD) analysis and Scanning Electron Microscope (SEM) imaging. Fourier Transform Infrared (FT-IR) spectrum of the synthesized polycrystalline powder sample was also recorded. The TL glow curves were analyzed to determine various dosimetric characteristics of the synthesized luminophosphors. The dose response increased in a ;linear; way with the beta-ray exposure between 0.1-20 Gy, a dose range being interested in medical dosimetry. The response with changing photon and electron energy was studied. The rate of decay of the TL signal was investigated both for dark storage and under direct sunlight. Li2B4O7:Cu, B showed no individual variation of response in 9 recycling measurements. The fluorescence spectrum was determined. The kinetic parameters were estimated by different methods and the results discussed. The studied properties of synthesized Li2B4O7:Cu, B were found all favorable for dosimetric purposes.

  1. Phosphors for X-ray intensification screens

    International Nuclear Information System (INIS)

    Rebatin, J.G.

    1980-01-01

    An improved rare earth oxyhalide phosphor for x-ray intensification screens is described. The phosphors, of formula LnOX.T where Ln = La or Gd, X = Cl or Br and T = Tm or Tb, are mixed with a small amount of a trivalent antimony compound. The addition of antimony overcomes ageing due to attack by atmospheric moisture and renders the phosphor freeflowing so that dispersions can be readily made. Preferably the phosphor is washed with an aqueous solution of the antimony compound and the compound is the fluoride, chloride or butoxide, or potassium antimony tartrate. (U.K.)

  2. Development and evaluation of a low-cost and high-capacity DICOM image data storage system for research.

    Science.gov (United States)

    Yakami, Masahiro; Ishizu, Koichi; Kubo, Takeshi; Okada, Tomohisa; Togashi, Kaori

    2011-04-01

    Thin-slice CT data, useful for clinical diagnosis and research, is now widely available but is typically discarded in many institutions, after a short period of time due to data storage capacity limitations. We designed and built a low-cost high-capacity Digital Imaging and COmmunication in Medicine (DICOM) storage system able to store thin-slice image data for years, using off-the-shelf consumer hardware components, such as a Macintosh computer, a Windows PC, and network-attached storage units. "Ordinary" hierarchical file systems, instead of a centralized data management system such as relational database, were adopted to manage patient DICOM files by arranging them in directories enabling quick and easy access to the DICOM files of each study by following the directory trees with Windows Explorer via study date and patient ID. Software used for this system was open-source OsiriX and additional programs we developed ourselves, both of which were freely available via the Internet. The initial cost of this system was about $3,600 with an incremental storage cost of about $900 per 1 terabyte (TB). This system has been running since 7th Feb 2008 with the data stored increasing at the rate of about 1.3 TB per month. Total data stored was 21.3 TB on 23rd June 2009. The maintenance workload was found to be about 30 to 60 min once every 2 weeks. In conclusion, this newly developed DICOM storage system is useful for research due to its cost-effectiveness, enormous capacity, high scalability, sufficient reliability, and easy data access.

  3. [The reduction of the radiation dosage by means of storage phosphor-film radiography compared to a conventional film-screen system with a grid cassette on a skull phantom].

    Science.gov (United States)

    Heyne, J P; Merbold, H; Sehner, J; Neumann, R; Freesmeyer, M; Jonetz-Mentzel, L; Kaiser, W A

    1999-07-01

    How much can the radiation dose be reduced for skull radiography by using digital luminescence radiography (DLR) compared to a conventional screen film system with a grid cassette? A skull phantom (3M) was x-rayed in anterior-posterior orientation using both a conventional screen film system with grid cassette and DLR (ADC-70, Agfa). The tube current time product (mAs) was diminished gradually while keeping the voltage constant. The surface entrance dose was measured by a sensor of Dosimax (Wellhöfer). Five investigators evaluated the images by characteristic and critical features, spatial resolution and contrast. The surface entrance dose at 73 kV/22 mAs was 0.432 mGy in conventional screen film system and 0.435 mGy in DLR. The images could be evaluated very well down to an average dose of 71% (0.308 mGy; SD 0.050); sufficient images were obtained down to an average dose of 31% (0.136 mGy; SD 0.065). The resolution of the line pairs were reduced down to 2 levels depending on the investigator. Contrast was assessed as being very good to sufficient. The acceptance of the postprocessed images (MUSICA-software) was individually different and resulted in an improvement of the assessment of bone structures and contrast in higher dose ranges only. For the sufficient assessment of a possible fracture/of paranasal sinuses/of measurement of the skull the dose can be reduced to at least 56% (phi 31%; SD 14.9%)/40% (phi 27%; SD 9.3%)/18% (phi 14%; SD 4.4%). Digital radiography allows question-referred exposure parameters with clearly reduced dose, so e.g. for fracture exclusion 73 kV/12.5 mAs and to skull measurement 73 kV/4 mAs.

  4. A novel red-emitting phosphor for white light-emitting diodes

    International Nuclear Information System (INIS)

    Ren, Fuqiang; Chen, Donghua

    2010-01-01

    A novel red-emitting phosphor of Eu 3+ -activated molybdate was prepared at 850 o C by a modified solid-state reaction. Photoluminescence (PL) results showed that the phosphor can be efficiently excited by UV-visible light from 350 to 550 nm, and exhibited bright red emission at 614 nm. XPS are taken to investigate the structure and compositions of this material. The crystallization and particle sizes of the phosphor have been investigated by using powder X-ray diffraction (XRD) and transmission electron microscopy (TEM). TEM images show that the grain size of the phosphor is about 30 nm which is in full agreement with the theoretical calculation data from the XRD patterns.

  5. Structural optimization for remote white light-emitting diodes with quantum dots and phosphor: packaging sequence matters.

    Science.gov (United States)

    Xie, Bin; Chen, Wei; Hao, Junjie; Wu, Dan; Yu, Xingjian; Chen, Yanhua; Hu, Run; Wang, Kai; Luo, Xiaobing

    2016-12-26

    White light-emitting diodes (WLEDs) with quantum dots (QDs) and phosphor have attracted tremendous attentions due to their excellent color rendering ability. In the packaging process, QDs layer and phosphor-silicone layer tend to be separated to reduce the reabsorption losses, and to maintain the stability of QDs surface ligands. This study investigated the packaging sequence between QDs and phosphor on the optical and thermal performances of WLEDs. The output optical power and PL spectra were measured and analyzed, and the temperature fields were simulated and validated experimentally by infrared thermal imager. It was found that when driven by 60 mA, the QDs-on-phosphor type WLEDs achieved luminous efficiency (LE) of 110 lm/W, with color rendering index (CRI) of Ra = 92 and R9 = 80, while the phosphor-on-QDs type WLEDs demonstrated lower LE of 68 lm/W, with Ra = 57 and R9 = 24. Moreover, the QDs-on-phosphor type WLEDs generated less heat than that of another, consequently the highest temperature in the QDs-on-phosphor type was lower than another, and the temperature difference can reach 12.3°C. Therefore, in terms of packaging sequence, the QDs-on-phosphor type is an optimal packaging architecture for higher optical efficiency, better color rendering ability and lower device temperature.

  6. Digital mammography with high-resolution storage plates (CR) versus full-field digital mammography (CCD) (DR) for microcalcifications and focal lesions - a retrospective clinical histologic analysis (n = 102)

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Lell, M.; Wenkel, E.; Boehner, C.; Dassel, M.S.; Bautz, W.

    2005-01-01

    Purpose: to determine the diagnostic accuracy of microcalcifications and focal lesions in a retrospective clinical-histological study using high-resolution digital phosphor storage plates (hard copy) and full-field digital mammography (hard copy). Materials and methods: from May 2003 to September 2003, 102 patients underwent digital storage plate mammography (CR), using a mammography unit (Mammomat 3000 N, Siemens) in combination with a high resolution (9 lp/mm) digital storage phosphor plate system (pixel size 50 μm) (Fuji/Siemens). After diagnosis and preoperative wire localization, full-field digital mammography (CCD) (DR) was performed with the same exposure parameters. The full-field digital mammography used a CCD-detector (SenoScan) (fisher imaging) with a resolution of 10 Ip/mm and a pixel size of 50 μm. Five investigators determined the diagnosis (BI-RADS trademark I-V) retrospectively after the operation from randomly distributed mediolateral views (hard copy reading). These results were correlated with the final histology. Results: the diagnostic accuracy of digital storage plate mammography (CR) and full-field digital mammography (CCD) (DR) was 73% and 71% for all findings (n = 102), 73% and 71% for microcalcifications (n = 51), and 72% and 70% for focal lesions (n = 51). The overall results showed no difference. Conclusion: our findings indicate the equivalence of high-resolution digital phosphor storage plate mammography (CR) and full-field digital mammography (CCD) (DR). (orig.)

  7. Neutron imaging methods for the investigation of energy related materials. Fuel cells, battery, hydrogen storage and nuclear fuel

    Science.gov (United States)

    Lehmann, Eberhard H.; Boillat, Pierre; Kaestner, Anders; Vontobel, Peter; Mannes, David

    2015-10-01

    After a short explanation of the state-of-the-art in the field of neutron imaging we give some examples how energy related materials can be studied successfully. These are in particular fuel cell studies, battery research approaches, the storage of hydrogen, but also some investigations with nuclear fuel components. The high contrast for light isotopes like H-1, Li-6 or B-10 are used to trace low amounts of material even within compact sealing of metals which are relatively transparent for neutrons at the same time.

  8. Adult onset glycogen storage disease type II (adult onset Pompe disease): report and magnetic resonance images of two cases

    International Nuclear Information System (INIS)

    Del Gaizo, Andrew; Banerjee, Sima; Terk, Michael

    2009-01-01

    Glycogen storage disease type II (GSDII), also referred to as Pompe disease or acid maltase deficiency, is a rare inherited condition caused by a deficiency in acid alpha-glucosidase (GAA) enzyme activity. The condition is often classified by age of presentation, with infantile and late onset variants (Laforet et al. J Neurology 55:1122-8, 2000). Late onset tends to present with progressive proximal muscle weakness and respiratory insufficiency (Winkel et al. J Neurology 252:875-84, 2005). We report two cases of biopsy confirmed adult onset GSDII, along with key Magnetic Resonance (MR) images. (orig.)

  9. Pretreatment of industrial phosphoric acid by Algerian filter-aids

    International Nuclear Information System (INIS)

    Mellah, A.; Setti, Louisa; Chegrouche, Salah

    1993-01-01

    The present work involves the filtration of industrial phosphoric acid by different filter-aids such as kieselguhr, celite and bleaching clay. The retention of substances contained in wet phosphoric acid was determined using the three filter-aids. Thus, the phosphoric acid, obtained by filtration on kieselguhr has the same specifications as technical phosphoric acid produced by Rhone-Poulenc (France) as standard

  10. Method of purifying phosphoric acid after solvent extraction

    International Nuclear Information System (INIS)

    Kouloheris, A.P.; Lefever, J.A.

    1979-01-01

    A method of purifying phosphoric acid after solvent extraction is described. The phosphoric acid is contacted with a sorbent which sorbs or takes up the residual amount of organic carrier and the phosphoric acid separated from the organic carrier-laden sorbent. The method is especially suitable for removing residual organic carrier from phosphoric acid after solvent extraction uranium recovery. (author)

  11. 46 CFR 151.50-23 - Phosphoric acid.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Phosphoric acid. 151.50-23 Section 151.50-23 Shipping... BULK LIQUID HAZARDOUS MATERIAL CARGOES Special Requirements § 151.50-23 Phosphoric acid. (a) The term phosphoric acid as used in this subpart shall include, in addition to phosphoric acid, aqueous solutions of...

  12. Self-dose and fading of CaSO4(Dy/Tm) and CaF2 (natural) TL phosphors in environmental radiation monitoring

    International Nuclear Information System (INIS)

    Nambi, K.S.V.

    1982-01-01

    A 'shielded storage experiment' for estimating both the 'self-dose' and 'fading' of TL phosphors under conditions akin to those faced in environmental monitoring applications is described. Using this method, self-dose rates of 0.32 +- 0.10(sigma) μ rad h -1 and 1.16 +- 0.02(sigma) μ rad h -1 have been obtained for CaF 2 (natural) and CaSO 4 (Dy) phosphors; the thermal decay constants at 25 0 C for these phosphors turn out to be 27 X 10 -6 h -6 ad 12 X 10 -6 h -1 , respectively. Estimation of the self-doses from radioactivity measurements of the phosphors concerned is also presented and the differences explained. A very high self-dose rate of 5.6 μ rad h -1 was estimated by the latter method for a sample of CaSO 4 (Tm) phosphor. (orig.)

  13. Phosphorous-Containing Polymers for Regenerative Medicine

    Science.gov (United States)

    Watson, Brendan M.; Kasper, F. Kurtis; Mikos, Antonios G.

    2014-01-01

    Disease and injury have resulted in a large, unmet need for functional tissue replacements. Polymeric scaffolds can be used to deliver cells and bioactive signals to address this need for regenerating damaged tissue. Phosphorous-containing polymers have been implemented to improve and accelerate the formation of native tissue both by mimicking the native role of phosphorous groups in the body and by attachment of other bioactive molecules. This manuscript reviews the synthesis, properties, and performance of phosphorous-containing polymers that can be useful in regenerative medicine applications. PMID:24565855

  14. A general XML schema and SPM toolbox for storage of neuro-imaging results and anatomical labels.

    Science.gov (United States)

    Keator, David Bryant; Gadde, Syam; Grethe, Jeffrey S; Taylor, Derek V; Potkin, Steven G

    2006-01-01

    With the increased frequency of multisite, large-scale collaborative neuro-imaging studies, the need for a general, self-documenting framework for the storage and retrieval of activation maps and anatomical labels becomes evident. To address this need, we have developed and extensible markup language (XML) schema and associated tools for the storage of neuro-imaging activation maps and anatomical labels. This schema, as part of the XML-based Clinical Experiment Data Exchange (XCEDE) schema, provides storage capabilities for analysis annotations, activation threshold parameters, and cluster and voxel-level statistics. Activation parameters contain information describing the threshold, degrees of freedom, FWHM smoothness, search volumes, voxel sizes, expected voxels per cluster, and expected number of clusters in the statistical map. Cluster and voxel statistics can be stored along with the coordinates, threshold, and anatomical label information. Multiple threshold types can be documented for a given cluster or voxel along with the uncorrected and corrected probability values. Multiple atlases can be used to generate anatomical labels and stored for each significant voxel or cluter. Additionally, a toolbox for Statistical Parametric Mapping software (http://www. fil. ion.ucl.ac.uk/spm/) was created to capture the results from activation maps using the XML schema that supports both SPM99 and SPM2 versions (http://nbirn.net/Resources/Users/ Applications/xcede/SPM_XMLTools.htm). Support for anatomical labeling is available via the Talairach Daemon (http://ric.uthscsa. edu/projects/talairachdaemon.html) and Automated Anatomical Labeling (http://www. cyceron.fr/freeware/).

  15. Digital X-ray Imaging in Dentistry

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    1999-01-01

    In dentistry, Radio Visio Graphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter, many types of direct digital radiographic systems have been produced in the last decade. They are based either on charge-coupled device (CCD) or on storage phosphor technology. In addition, new types of digital radiographic system using amorphous selenium, image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose, image processing, computer storage, electronic transfer of images and so on. Image processing includes image enhancement, image reconstruction, digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system (IMACS) for dentomaxillofacial radiology was reported in 1992, IMACS in dental hospital has been increasing. Meanwhile, researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible, feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis, have been performed actively in the last decade. Further developments in digital radiographic imaging modalities, image transmission system, imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  16. Digital X-ray Imaging in Dentistry

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Dankook University, Yongin (Korea, Republic of)

    1999-08-15

    In dentistry, Radio Visio Graphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter, many types of direct digital radiographic systems have been produced in the last decade. They are based either on charge-coupled device (CCD) or on storage phosphor technology. In addition, new types of digital radiographic system using amorphous selenium, image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose, image processing, computer storage, electronic transfer of images and so on. Image processing includes image enhancement, image reconstruction, digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system (IMACS) for dentomaxillofacial radiology was reported in 1992, IMACS in dental hospital has been increasing. Meanwhile, researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible, feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis, have been performed actively in the last decade. Further developments in digital radiographic imaging modalities, image transmission system, imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  17. Combustion synthesis and photoluminescence in novel red emitting yttrium gadolinium pyrosilicate nanocrystalline phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Hedaoo, V.P., E-mail: vraikwar@rediffmail.com [Department of Physics, R. J. College, Ghatkopar, Mumbai, MS 400086 (India); Bhatkar, V.B. [Department of Physics, Shri Shivaji Science College, Amravati, MS 444602 (India); Omanwar, S.K. [Department of Physics, SGB Amravati University, Amravati, MS 444602 (India)

    2016-07-05

    Yttrium Gadolinium Pyrosilicate Y{sub 2-x}Gd{sub x}Si{sub 2}O{sub 7}:Eu{sup 3+} (x = 0.05, 0.10, 0.15) phosphor powder was prepared by facile and time efficient modified combustion method for the first time. The phosphor was characterized by powder X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), photoluminescence excitation (PLE) and emission (PL) spectroscopy and color chromaticity coordinates. XRD revealed the monoclinic crystal structure with space group P1¯. The crystallite size was calculated by Williamson-Hall (W–H) analysis. Nanoplates-like morphology was observed in FESEM analysis with size in the range 50–80 nm. TEM images confirmed the particle size and shape. Upon excitation by 254 nm UV light, the phosphor showed the characteristic red emission peaks at 589 nm and 613 nm corresponding to {sup 5}D{sub 0} → {sup 7}F{sub 1} and {sup 5}D{sub 0} → {sup 7}F{sub 2} transitions respectively. It was observed that the nanocrystalline phosphor Y{sub 2-x}Gd{sub x}Si{sub 2}O{sub 7}:Eu{sup 3+}can be tuned to emit orange to red color by adjusting the ratio Y/Gd. This phosphor thus can be a potential candidate as orange to red color emitting tunable nanocrystalline phosphor for optical devices. - Highlights: • A novel Yttrium Gadolinium Pyrosilicate doped with Eu{sup 3+} is reported. • Facile and time efficient modified combustion method is used. • The nanocrystalline structure was shown by X-ray diffraction, W–H analysis. • FESEM and TEM images confirmed the nanocrystalline structure. • The reported phosphor can be tuned from orange to red by varying Y/Gd ratio.

  18. Structural and morphological changes in supramolecular-structured polymer electrolyte membrane fuel cell on addition of phosphoric acid

    Science.gov (United States)

    Hendrana, S.; Pryliana, R. F.; Natanael, C. L.; Rahayu, I.

    2018-03-01

    Phosphoric acid is one agents used in membrane fuel cell to modify ionic conductivity. Therefore, its distribution in membrane is a key parameter to gain expected conductivity. Efforts have been made to distribute phosphoric acid in a supramolecular-structured membrane prepared with a matrix. To achieve even distribution across bulk of the membrane, the inclusion of the polyacid is carried out under pressurized chamber. Image of scanning electron microscopy (SEM) shows better phosphoric acid distribution for one prepared in pressurized state. It also leads in better performing in ionic conductivity. Moreover, data from differential scanning calorimetry (DSC) indicate that the addition of phosphoric acid is prominent in the change of membrane structure, while morphological changes are captured in SEM images.

  19. Effects of imaging gradients in sequences with varying longitudinal storage time-Case of diffusion exchange imaging

    DEFF Research Database (Denmark)

    Lasic, Samo; Lundell, Henrik; Topgaard, Daniel

    2017-01-01

    low-pass diffusion filtering during the LS interval, which is more pronounced at lower exchange rates. For a total exchange rate constant larger than 1 s-1, the AXR bias is expected to be negligible when slices thicker than 2.5mm are used. Conclusion: In correlation experiments like FEXI, relying...... on LS with variable duration, imaging gradients may cause disrupting effects that cannot be easily mitigated and should be carefully considered for unbiased results. In typical clinical applications of FEXI, the imaging gradients are expected to cause a negligible AXR bias. However, the AXR bias may...

  20. Characteristics of the Panasonic UD-802 phosphors

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; Catchen, G.L.; Hoffman, J.M.

    1989-01-01

    Several basic dosimetric characteristics of Li 2 B 4 O 7 :Cu and CaSO 4 :Tm phosphors in Panasonic UD-802 dosemeters were measured. The TL dose response linearity was determined over the useful range of personnel and environmental dosimetry (0.005 - 10 mGy), and the minimum measurable doses were calculated. The intrinsic ultraviolet (UV) radiation sensitivity of both phosphors was checked before and after γ irradiation for the purpose of re-assessing high doses. The results indicate that Li 2 B 4 O 7 :Cu is UV sensitive and, therefore, re-assessment is not applicable. Although the CaSO 4 :Tm phosphor exhibited UV sensitivity after γ irradiation, the results were not consistent with those reported earlier and more study is required. The fading of both phosphors was evaluated in Panasonic UD-801 dosemeters for periods up to 90 days. (author)

  1. Phosphate Phosphors for Solid-State Lighting

    CERN Document Server

    Shinde, Kartik N; Swart, H C; Park, Kyeongsoon

    2012-01-01

    The idea for this book arose out of the realization that, although excellent surveys and a phosphor handbook are available, there is no single source covering the area of phosphate based phosphors especially for lamp industry. Moreover, as this field gets only limited attention in most general books on luminescence, there is a clear need for a book in which attention is specifically directed toward this rapidly growing field of solid state lighting and its many applications. This book is aimed at providing a sound introduction to the synthesis and optical characterization of phosphate phosphor for undergraduate and graduate students as well as teachers and researchers. The book provides guidance through the multidisciplinary field of solid state lighting specially phosphate phosphors for beginners, scientists and engineers from universities, research organizations, and especially industry. In order to make it useful for a wide audience, both fundamentals and applications are discussed, together.

  2. Electrolyte Additives for Phosphoric Acid Fuel Cells

    DEFF Research Database (Denmark)

    Gang, Xiao; Hjuler, H.A.; Olsen, C.A.

    1993-01-01

    , as a fuel-cell performance with the modified electrolytes. Specific conductivity measurements of some of the modified phosphoric acid electrolytes are reported. At a given temperature, the conductivity of the C4F9SO3K-modified electrolyte decreases with an increasing amount of the additive; the conductivity...... of the remains at the same value as the conductivity of the pure phosphoric acid. At a given composition, the conductivity of any modified electrolyte increases with temperature. We conclude that the improved cell performance for modified electrolytes is not due to any increase in conductivity.......Electrochemical characteristics of a series of modified phosphoric acid electrolytes containing fluorinated car on compounds and silicone fluids as additives are presented. When used in phosphoric acid fuel cells, the modified electrolytes improve the performance due to the enhanced oxygen...

  3. Imaging through obscurations for sluicing operations in the waste storage tanks

    International Nuclear Information System (INIS)

    Peters, T.J.; McMakin, D.L.; Sheen, D.M.; Chieda, M.A.

    1994-08-01

    Waste remediators have identified that surveillance of waste remediation operations and periodic inspections of stored waste are required under very demanding and difficult viewing environments. In many cases, obscurants such as dust or water vapor are generated as part of the remediation activity. Methods are required for viewing or imaging beyond the normal visual spectrum. Work space images guide the movement of remediation equipment, creating a need for rapidly updated, near real-time imaging capability. In addition, there is a need for three-dimensional topographical data to determine the contours of the wastes, to plan retrieval campaigns, and to provide a three-dimensional map of a robot's work space as basis for collision avoidance. Three basic imaging techniques were evaluated: optical, acoustic and radar. The optical imaging methods that were examined used cameras which operated in the visible region and near-infrared region and infrared cameras which operated in the 3--5 micron and 8--12 micron wavelength regions. Various passive and active lighting schemes were tested, as well as the use of filters to eliminate reflection in the visible region. Image enhancement software was used to extend the range where visual techniques could be used. In addition, the operation of a laser range finder, which operated at 0.835 microns, was tested when fog/water droplets were suspended in the air. The acoustic technique involved using commercial acoustic sensors, operating at approximately 50 kHz and 215 kHz, to determine the attenuation of the acoustic beam in a high-humidity environment. The radar imaging methods involved performing millimeter wave (94 GHz) attenuation measurement sin the various simulated sluicing environments and performing preliminary experimental imaging studies using a W-Band (75--110 GHz) linearly scanned transceiver in a laboratory environment. The results of the tests are discussed

  4. Lanthanide-doped upconverting phosphors for bioassay and therapy

    Science.gov (United States)

    Guo, Huichen; Sun, Shiqi

    2012-10-01

    Lanthanide-doped fluorescent materials have gained increasing attention in recent years due to their unique luminescence properties which have led to their use in wide-ranging fields including those of biological applications. Aside from being used as agents for in vivo imaging, lanthanide-doped fluorescent materials also present many advantages for use in bioassays and therapy. In this review, we summarize the applications of lanthanide-doped up-converting phosphors (UCPs) in protein and gene detection, as well as in photodynamic and gene therapy in recent years, and outline their future potential in biological applications. The current report could serve as a reference for researchers in relevant fields.

  5. Improving radiochromic film's sensitivity by wrapping it with UV phosphor

    International Nuclear Information System (INIS)

    Geso, Moshi; Ackerly, Trevor; Patterson, William

    2004-01-01

    The main advantage of radiochromic-film dosimeters is the coupling of rapid full planar-acquisition, high-spatial resolution and dose linearity. Their main limitation, however, is their low radiation sensitivity. This precludes their application to measuring doses below a few Gy. Radiochromic films are sensitive to ultraviolet radiation. In this note the results of exposing radiochromic films to x rays through an UV imaging cassette, which converts and amplifies x rays to UV radiation, are presented. These results indicate a clear increase (around 50%) in radiochromic film's sensitivity to MV x rays (6, 10, and 18 MV) when exposed through the UV phosphor

  6. Fluorescent lighting with aluminum nitride phosphors

    Science.gov (United States)

    Cherepy, Nerine J.; Payne, Stephen A.; Seeley, Zachary M.; Srivastava, Alok M.

    2016-05-10

    A fluorescent lamp includes a glass envelope; at least two electrodes connected to the glass envelope; mercury vapor and an inert gas within the glass envelope; and a phosphor within the glass envelope, wherein the phosphor blend includes aluminum nitride. The phosphor may be a wurtzite (hexagonal) crystalline structure Al.sub.(1-x)M.sub.xN phosphor, where M may be drawn from beryllium, magnesium, calcium, strontium, barium, zinc, scandium, yttrium, lanthanum, cerium, praseodymium, europium, gadolinium, terbium, ytterbium, bismuth, manganese, silicon, germanium, tin, boron, or gallium is synthesized to include dopants to control its luminescence under ultraviolet excitation. The disclosed Al.sub.(1-x)M.sub.xN:Mn phosphor provides bright orange-red emission, comparable in efficiency and spectrum to that of the standard orange-red phosphor used in fluorescent lighting, Y.sub.2O.sub.3:Eu. Furthermore, it offers excellent lumen maintenance in a fluorescent lamp, and does not utilize "critical rare earths," minimizing sensitivity to fluctuating market prices for the rare earth elements.

  7. Non-destructive evaluation utilizing imaging plates for field radiography applications

    International Nuclear Information System (INIS)

    White, Brian S.

    2016-01-01

    The oil and gas industry has utilized film radiography for the evaluation of pipeline welds for many years. The world has evolved, and today people are easily sharing digital images as part of the information revolution. Computed radiography is ready to replace film radiography for portable outdoor use applications. Computed radiography technology adoption has been contingent upon achieving acceptable image quality and getting enough imaging plate use cycles to be profitable. Image quality is dependent upon shot conditions, imaging plate type, reader settings, and scatter control. Likewise, the number of achievable use cycles is dependent upon the imaging plate design for durability and the user's operating environment. This presentation reviews the basic principles of storage phosphor imaging plates. Usage criteria and guidelines for optimum image quality and maximized overall use cycles will be discussed for various imaging plate types. A comparison of film and computed radiography imaging plate technology will be presented.

  8. Real-time prediction of pre-cooked Japanese sausage color with different storage days using hyperspectral imaging.

    Science.gov (United States)

    Feng, Chao-Hui; Makino, Yoshio; Yoshimura, Masatoshi; Rodríguez-Pulido, Francisco J

    2018-05-01

    Redness can greatly influence the freshness of sausages. A precise, rapid and noncontact analytical method or tool is needed to quantify the color. Hyperspectral imaging (HSI) is an emerging technique that integrates spectroscopy and imaging to obtain the spectral and spatial information simultaneously. In the present study, the redness of cooked sausages stored up to 57 days was predicted using HSI in tandem with multivariate data analysis. The mean spectra of the sausages were extracted from the hyperspectral images. Partial least squares regression (PLSR) and forward stepwise multiple regression (FSMR) models were used to develop the relavent spectral profiles with the redness of the cooked sausages. Ten important wavelengths were selected based on the regression coefficient values from the PLSR model. The PLSR model established using the full wavelengths presented a good performance, with R c of 0.934 and a root mean square error of calibration of 0.642 (redness ranged between 14.99 and 21.48). The prediction maps for demonstrating evolution of redness in sausages were developed for the first time using R statistics (R Foundation for Statistical Computing) and Matlab (MathWorks Inc., Natick, MA, USA). HSI combined with PLSR and FSMR can be used to quantify and visualize evolution of sausage redness under different storage days. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  9. Luminescence Studies on Lamp Phosphors

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, J.S.; Godbole, S.V.; Varadharajan, G.; Page, A.G

    1998-07-01

    Photoluminescence and thermoluminescence of cerium magnesium aluminate CeMgAl{sub 11}O{sub 17}(Eu,Tb) and calcium halophosphate Ca{sub 5}(PO{sub 4}){sub 3}(F,Cl):Mn,Sb, two fluorescent materials currently in use for the commercial production of lamps in India, have been studied for possible applications in radiation and ultraviolet dosimetry. Cerium magnesium aluminate is highly sensitive to the visible spectral region. It has a linear response to 254 nm UV radiation over a wide range. Its UV sensitivity is significantly higher as compared to that of other known phosphors; however, its UV response is rate-dependent and may not play a significant role in UV dosimetry. Photoluminescence of CeMg aluminate is characteristic of Eu{sup 2+} and Tb{sup 3+} dopants, whereas the thermoluminescence emission of the UV irradiated powder at room temperature is dominated by Eu{sup 2+} dopant. Calcium halophosphate is insensitive to room lights, has a linear gamma response over 0.2-10{sup 2} Gy and may be useful in the case of radiation accidents. (author)

  10. Luminescence Studies on Lamp Phosphors

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Godbole, S.V.; Varadharajan, G.; Page, A.G.

    1998-01-01

    Photoluminescence and thermoluminescence of cerium magnesium aluminate CeMgAl 11 O 17 (Eu,Tb) and calcium halophosphate Ca 5 (PO 4 ) 3 (F,Cl):Mn,Sb, two fluorescent materials currently in use for the commercial production of lamps in India, have been studied for possible applications in radiation and ultraviolet dosimetry. Cerium magnesium aluminate is highly sensitive to the visible spectral region. It has a linear response to 254 nm UV radiation over a wide range. Its UV sensitivity is significantly higher as compared to that of other known phosphors; however, its UV response is rate-dependent and may not play a significant role in UV dosimetry. Photoluminescence of CeMg aluminate is characteristic of Eu 2+ and Tb 3+ dopants, whereas the thermoluminescence emission of the UV irradiated powder at room temperature is dominated by Eu 2+ dopant. Calcium halophosphate is insensitive to room lights, has a linear gamma response over 0.2-10 2 Gy and may be useful in the case of radiation accidents. (author)

  11. MULTI-PHOTON PHOSPHOR FEASIBILITY RESEARCH

    Energy Technology Data Exchange (ETDEWEB)

    R. Graham; W. Chow

    2003-05-01

    Development of multi-photon phosphor materials for discharge lamps represents a goal that would achieve up to a doubling of discharge (fluorescent) lamp efficacy. This report reviews the existing literature on multi-photon phosphors, identifies obstacles in developing such phosphors, and recommends directions for future research to address these obstacles. To critically examine issues involved in developing a multi-photon phosphor, the project brought together a team of experts from universities, national laboratories, and an industrial lamp manufacturer. Results and findings are organized into three categories: (1) Multi-Photon Systems and Processes, (2) Chemistry and Materials Issues, and (3) Concepts and Models. Multi-Photon Systems and Processes: This category focuses on how to use our current understanding of multi-photon phosphor systems to design new phosphor systems for application in fluorescent lamps. The quickest way to develop multi-photon lamp phosphors lies in finding sensitizer ions for Gd{sup 3+} and identifying activator ions to red shift the blue emission from Pr{sup 3+} due to the {sup 1}S{sub 0} {yields} {sup 1}I{sub 6} transition associated with the first cascading step. Success in either of these developments would lead to more efficient fluorescent lamps. Chemistry and Materials Issues: The most promising multi-photon phosphors are found in fluoride hosts. However, stability of fluorides in environments typically found in fluorescent lamps needs to be greatly improved. Experimental investigation of fluorides in actual lamp environments needs to be undertaken while working on oxide and oxyfluoride alternative systems for backup. Concepts and Models: Successful design of a multi-photon phosphor system based on cascading transitions of Gd{sup 3+} and Pr{sup 3+} depends critically on how the former can be sensitized and the latter can sensitize an activator ion. Methods to predict energy level diagrams and Judd-Ofelt parameters of multi

  12. [Digitalization, archival storage and use of image documentation in the GastroBase-II system].

    Science.gov (United States)

    Kocna, P

    1997-05-14

    "GastroBase-II" is a module of the clinical information system "KIS-ComSyD"; The main part is represented by structured data-text with an expert system including on-line image digitalization in gastroenterology (incl. endoscopic, X-ray and endosonography pictures). The hardware and software of the GastroBase are described as well as six-years experiences with application of digitalized image data. An integration of a picture into text, reports, slides for a lecture or an electronic atlas is documented with examples. Briefly are reported out experiences with graphic editors (PhotoStyler), text editor (WordPerfect) and slide preparation for lecturing with the presentation software PowerPoint. The multimedia applications on the CD-ROM illustrate a modern trend using digitalized image documentation for pregradual and postgradual education.

  13. Live Cell Imaging During Germination Reveals Dynamic Tubular Structures Derived from Protein Storage Vacuoles of Barley Aleurone Cells

    Directory of Open Access Journals (Sweden)

    Verena Ibl

    2014-09-01

    Full Text Available The germination of cereal seeds is a rapid developmental process in which the endomembrane system undergoes a series of dynamic morphological changes to mobilize storage compounds. The changing ultrastructure of protein storage vacuoles (PSVs in the cells of the aleurone layer has been investigated in the past, but generally this involved inferences drawn from static pictures representing different developmental stages. We used live cell imaging in transgenic barley plants expressing a TIP3-GFP fusion protein as a fluorescent PSV marker to follow in real time the spatially and temporally regulated remodeling and reshaping of PSVs during germination. During late-stage germination, we observed thin, tubular structures extending from PSVs in an actin-dependent manner. No extensions were detected following the disruption of actin microfilaments, while microtubules did not appear to be involved in the process. The previously-undetected tubular PSV structures were characterized by complex movements, fusion events and a dynamic morphology. Their function during germination remains unknown, but might be related to the transport of solutes and metabolites.

  14. Phosphor blends for high-CRI fluorescent lamps

    Science.gov (United States)

    Setlur, Anant Achyut [Niskayuna, NY; Srivastava, Alok Mani [Niskayuna, NY; Comanzo, Holly Ann [Niskayuna, NY; Manivannan, Venkatesan [Clifton Park, NY; Beers, William Winder [Chesterland, OH; Toth, Katalin [Pomaz, HU; Balazs, Laszlo D [Budapest, HU

    2008-06-24

    A phosphor blend comprises at least two phosphors each selected from one of the groups of phosphors that absorb UV electromagnetic radiation and emit in a region of visible light. The phosphor blend can be applied to a discharge gas radiation source to produce light sources having high color rendering index. A phosphor blend is advantageously includes the phosphor (Tb,Y,LuLa,Gd).sub.x(Al,Ga).sub.yO.sub.12:Ce.sup.3+, wherein x is in the range from about 2.8 to and including 3 and y is in the range from about 4 to and including 5.

  15. Developing Quantum Dot Phosphor-Based Light-Emitting Diodes for Aviation Lighting Applications

    Directory of Open Access Journals (Sweden)

    Fengbing Wu

    2012-01-01

    Full Text Available We have investigated the feasibility of employing quantum dot (QD phosphor-based light-emitting diodes (LEDs in aviation applications that request Night Vision Imaging Systems (NVIS compliance. Our studies suggest that the emerging QD phosphor-based LED technology could potentially be superior to conventional aviation lighting technology by virtue of the marriage of tight spectral control and broad wavelength tunability. This largely arises from the fact that the optical properties of semiconductor nanocrystal QDs can be tailored by varying the nanocrystal size without any compositional changes. It is envisioned that the QD phosphor-based LEDs hold great potentials in cockpit illumination, back light sources of monitor screens, as well as the LED indicator lights of aviation panels.

  16. Developing Quantum Dot Phosphor-Based Light-Emitting Diodes for Aviation Lighting Applications

    International Nuclear Information System (INIS)

    Wu, F.; Dawei, Z.; Shuzhen, S.; Yiming, Z.; Songlin, Z.; Jian, X.

    2012-01-01

    We have investigated the feasibility of employing quantum dot (QD) phosphor-based light-emitting diodes (LEDs) in aviation applications that request Night Vision Imaging Systems (NVIS) compliance. Our studies suggest that the emerging QD phosphor-based LED technology could potentially be superior to conventional aviation lighting technology by virtue of the marriage of tight spectral control and broad wavelength tunability. This largely arises from the fact that the optical properties of semiconductor nano crystal QDs can be tailored by varying the nano crystal size without any compositional changes. It is envisioned that the QD phosphor-based LEDs hold great potentials in cockpit illumination, back light sources of monitor screens, as well as the LED indicator lights of aviation panels.

  17. Dissociative Recombination of HD+ - State-to-State Experimental Investigation Using Fragment Imaging and Storage Ring Techniques

    International Nuclear Information System (INIS)

    Amitay, Z.; Baer, A.; Dahan, M.; Levin, J.; Vager, Z.; Zajfman, D.

    1998-01-01

    When a molecular ion collides with a free electron it can capture the electron and dissociate. The resulting process of Dissociative Recombination (DR) is a process of great significance in a wide variety of plasma environments. In this process, the capture of a free electron leads to the formation of an highly excited state of the neutral molecule, which then dissociates into neutral fragments with kinetic energy and, possibly, internal excitation depending on the energy balance of the reaction. Despite its importance, the DR process is still not yet completely understood theoretically. This is mainly due to the complexity of the nature and dynamics of highly excited molecular states, especially when several channels are involved, as is usually the situation in DR. from experimental point of view, for direct comparison between experiment and theory, this complexity requires detailed experimental data, including the knowledge of both the initial state of the molecular ion, to which DR is very sensitive, and of the final quantum states of the DR products. Inherent un- certainties in the initial vibrational excitation of the laboratory molecular ions was the main drawback of the experiments conducted over the years to, study DR. A substantial progress in the understanding of the DR process was achieved with the introduction (about five years ago) of a new experimental approach, which uses heavy-ion storage ring technique. In a storage ring, one can store many molecular ions for a time which is long enough to allow complete radiative deexcitation of tile initial electronic and vibrational excitation coming from the ion source. Those vibrationally cold ions are then merged with an intense electron beam to measure their DR cross section. Further experimental progress was the inclusion of two and three-dimensional molecular imaging techniques [1] for the measurement of the branching ratio to different final quantum states of the neutral DR fragments. This talk will

  18. Color stable manganese-doped phosphors

    Science.gov (United States)

    Lyons, Robert Joseph [Burnt Hills, NY; Setlur, Anant Achyut [Niskayuna, NY; Deshpande, Anirudha Rajendra [Twinsburg, OH; Grigorov, Ljudmil Slavchev [Sofia, BG

    2012-08-28

    A process for preparing color stable Mn.sup.+4 doped phosphors includes providing a phosphor of formula I; A.sub.x[MF.sub.y]:Mn.sup.+4 I and contacting the phosphor in particulate form with a saturated solution of a composition of formula II in aqueous hydrofluoric acid; A.sub.x[MF.sub.y]; II wherein A is Li, Na, K, Rb, Cs, NR.sub.4 or a combination thereof; M is Si, Ge, Sn, Ti, Zr, Al, Ga, In, Sc, Y, La, Nb, Ta, Bi, Gd, or a combination thereof; R is H, lower alkyl, or a combination thereof; x is the absolute value of the charge of the [MF.sub.y] ion; and y is 5, 6 or 7. In particular embodiments, M is Si, Ge, Sn, Ti, Zr, or a combination thereof. A lighting apparatus capable of emitting white light includes a semiconductor light source; and a phosphor composition radiationally coupled to the light source, and which includes a color stable Mn.sup.+4 doped phosphor.

  19. Automatically Identifying Fusion Events between GLUT4 Storage Vesicles and the Plasma Membrane in TIRF Microscopy Image Sequences

    Directory of Open Access Journals (Sweden)

    Jian Wu

    2015-01-01

    Full Text Available Quantitative analysis of the dynamic behavior about membrane-bound secretory vesicles has proven to be important in biological research. This paper proposes a novel approach to automatically identify the elusive fusion events between VAMP2-pHluorin labeled GLUT4 storage vesicles (GSVs and the plasma membrane. The differentiation is implemented to detect the initiation of fusion events by modified forward subtraction of consecutive frames in the TIRFM image sequence. Spatially connected pixels in difference images brighter than a specified adaptive threshold are grouped into a distinct fusion spot. The vesicles are located at the intensity-weighted centroid of their fusion spots. To reveal the true in vivo nature of a fusion event, 2D Gaussian fitting for the fusion spot is used to derive the intensity-weighted centroid and the spot size during the fusion process. The fusion event and its termination can be determined according to the change of spot size. The method is evaluated on real experiment data with ground truth annotated by expert cell biologists. The evaluation results show that it can achieve relatively high accuracy comparing favorably to the manual analysis, yet at a small fraction of time.

  20. Energy storage

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This chapter discusses the role that energy storage may have on the energy future of the US. The topics discussed in the chapter include historical aspects of energy storage, thermal energy storage including sensible heat storage, latent heat storage, thermochemical heat storage, and seasonal heat storage, electricity storage including batteries, pumped hydroelectric storage, compressed air energy storage, and superconducting magnetic energy storage, and production and combustion of hydrogen as an energy storage option

  1. Image storage in coumarin-based copolymer thin films by photoinduced dimerization.

    Science.gov (United States)

    Gindre, Denis; Iliopoulos, Konstantinos; Krupka, Oksana; Champigny, Emilie; Morille, Yohann; Sallé, Marc

    2013-11-15

    We report a technique to encode grayscale digital images in thin films composed of copolymers containing coumarins. A nonlinear microscopy setup was implemented and two nonlinear optical processes were used to store and read information. A third-order process (two-photon absorption) was used to photoinduce a controlled dimer-to-monomer ratio within a defined tiny volume in the material, which corresponds to each recorded bit of data. Moreover, a second-order process (second-harmonic generation) was used to read the stored information, which has been found to be highly dependent upon the monomer-to-dimer ratio.

  2. White light quality of phosphor converted light-emitting diodes: A phosphor materials perspective of view

    International Nuclear Information System (INIS)

    Sommer, Christian; Hartmann, Paul; Pachler, Peter; Hoschopf, Hans; Wenzl, Franz P.

    2012-01-01

    Highlights: ► We discuss the impact of the optical properties of a phosphor for colour temperature constancy in solid state lighting. ► Quantitative evaluation of permissible variations of the optical properties for batch-to-batch reproducibility. ► Quantitative evaluation of permissible variations of the optical properties upon temperature increase. ► Quantitative evaluation of permissible variations of the optical properties upon materials degradation. - Abstract: For a systematic approach to improve the white light quality of phosphor converted LEDs and to fulfil the demands for colour temperature reproducibility and constancy, it is imperative to understand how variations of the extinction coefficient and the quantum efficiency of the phosphor particles as well as variations of the excitation wavelength of the blue LED die affect the correlated colour temperature of the white LED source. Based on optical ray tracing of a phosphor converted white LED package we deduce permissible values for the variation of a given extinction coefficient and a given quantum efficiency of a phosphor material in order to maintain acceptable colour variations. These quantitative valuations of the required constancy of the optical properties of the phosphors will in particular provide some benchmarks for the synthesis of improved phosphor materials aiming at solid state lighting applications.

  3. Himage PACS: a new approach to storage, integration, and distribution of cardiologic images

    Science.gov (United States)

    Costa, Carlos M.; Silva, Augusto; Oliveira, Jose L.; Ribeiro, Vasco G.; Ribeiro, Jose

    2004-04-01

    This paper presents a Cardiology oriented information system that provides permanent availability of all clinical history, including alphanumeric and image data, with time and cost-effective transmission (reduced download time), without loss of image diagnosis quality and based on a Web Multimedia Integrated Access Interface. This implies the integration of HIS and PACS in a unique access interface, providing on-line and fast access to authorized healthcare professionals. The benefits obtained from the HIS-PACS integration and from the availability of all historical patient data are unquestionable to practitioners but also to the patients. Moreover, the system includes a telematic platform capable of establishing cooperative telemedicine sessions where our most impressive utilization is a transcontinental work platform for cardiovascular ultrasound. The key point of our approach starts with the construction of a DICOM private transfer syntax that is prepared to support any video encoder installed on a Windows-based station. With this structure it is possible to select the best encoder to a specific modality and work scenario. Good trade-off between compression ratio and diagnostic quality, low network traffic load, backup facilities and data portability are other achievements of this system.

  4. Fabrication of phosphor micro-grids using proton beam lithography

    International Nuclear Information System (INIS)

    Rossi, Paolo; Antolak, Arlyn J.; Provencio, Paula Polyak; Doyle, Barney Lee; Malmqvist, Klas; Hearne, Sean Joseph; Nilsson, Christer; Kristiansson, Per; Wegden, Marie; Elfman, Mikael; Pallon, Jan; Auzelyte, Vaida

    2005-01-01

    A new nuclear microscopy technique called ion photon emission microscopy or IPEM was recently invented. IPEM allows analysis involving single ions, such as ion beam induced charge (IBIC) or single event upset (SEU) imaging using a slightly modified optical microscope. The spatial resolution of IPEM is currently limited to more than 10 (micro)m by the scattering and reflection of ion-induced photons, i.e. light blooming or spreading, in the ionoluminescent phosphor layer. We are developing a 'Microscopic Gridded Phosphor' (also called Black Matrix) where the phosphor nanocrystals are confined within the gaps of a micrometer scale opaque grid, which limits the amount of detrimental light blooming. MeV-energy proton beam lithography is ideally suited to lithographically form masks for the grid because of high aspect ratio, pattern density and sub-micron resolution of this technique. In brief, the fabrication of the grids was made in the following manner: (1) a MeV proton beam focused to 1.5-2 (micro)m directly fabricated a matrix of pillars in a 15 (micro)m thick SU-8 lithographic resist; (2) 7:1 aspect ratio pillars were then formed by developing the proton exposed area; (3) Ni (Au) was electrochemically deposited onto Cu-coated Si from a sulfamate bath (or buffered CN bath); (4) the SU-8 pillars were removed by chemical etching; finally (5) the metal micro-grid was freed from its substrate by etching the underlying Cu layer. Our proposed metal micro-grids promise an order-of-magnitude improvement in the resolution of IPEM.

  5. An Approach Using Parallel Architecture to Storage DICOM Images in Distributed File System

    International Nuclear Information System (INIS)

    Soares, Tiago S; Prado, Thiago C; Dantas, M A R; De Macedo, Douglas D J; Bauer, Michael A

    2012-01-01

    Telemedicine is a very important area in medical field that is expanding daily motivated by many researchers interested in improving medical applications. In Brazil was started in 2005, in the State of Santa Catarina has a developed server called the CyclopsDCMServer, which the purpose to embrace the HDF for the manipulation of medical images (DICOM) using a distributed file system. Since then, many researches were initiated in order to seek better performance. Our approach for this server represents an additional parallel implementation in I/O operations since HDF version 5 has an essential feature for our work which supports parallel I/O, based upon the MPI paradigm. Early experiments using four parallel nodes, provide good performance when compare to the serial HDF implemented in the CyclopsDCMServer.

  6. Thermoluminescence properties of Li2B4O7:Cu, B phosphor synthesized using solution combustion technique

    International Nuclear Information System (INIS)

    Ozdemir, A.; Altunal, V.; Kurt, K.; Depci, T.; Yu, Y.; Lawrence, Y.; Nur, N.; Guckan, V.; Yegingil, Z.

    2017-01-01

    To determine the effects of various concentrations of the activators copper (Cu) and boron (B) on the thermoluminescence (TL) properties of lithium tetraborate, the phosphor was first synthesized and doped with five different concentrations of copper (0.1–0.005 wt%) using solution combustion method. 0.01 wt% Cu was the concentration which showed the most significant increase in the sensitivity of the phosphor. The second sort of Li 2 B 4 O 7 :Cu material was prepared by adding B (0.001–0.03 wt%) to it. The newly developed copper-boron activated lithium tetraborate (Li 2 B 4 O 7 :Cu, B) material with 0.01 wt% Cu and 0.001 wt% B impurity concentrations was shown to have promise as a TL phosphor. The material formation was examined using powder x-Ray Diffraction (XRD) analysis and Scanning Electron Microscope (SEM) imaging. Fourier Transform Infrared (FT-IR) spectrum of the synthesized polycrystalline powder sample was also recorded. The TL glow curves were analyzed to determine various dosimetric characteristics of the synthesized luminophosphors. The dose response increased in a “linear” way with the beta-ray exposure between 0.1–20 Gy, a dose range being interested in medical dosimetry. The response with changing photon and electron energy was studied. The rate of decay of the TL signal was investigated both for dark storage and under direct sunlight. Li 2 B 4 O 7 :Cu, B showed no individual variation of response in 9 recycling measurements. The fluorescence spectrum was determined. The kinetic parameters were estimated by different methods and the results discussed. The studied properties of synthesized Li 2 B 4 O 7 :Cu, B were found all favorable for dosimetric purposes. - Highlights: • Li 2 B 4 O 7 :Cu, B synthesis using solution combustion method with various concentrations. • Structure analysis of Li 2 B 4 O 7 :Cu, B using XRD, SEM and FTIR methods. • Investigation of thermoluminescent properties of Li 2 B 4 O 7 :Cu, B. • Relatively good

  7. High efficiency nitride based phosphores for white LEDs

    NARCIS (Netherlands)

    Li, Yuan Qiang; Hintzen, H.T.J.M.

    2008-01-01

    In this overview paper, novel rare-earth doped silicon nitride based phosphors for white LEDs applications have been demonstrated. The luminescence properties of orange-red-emitting phosphors (M2Si5N8:Eu2+) and green-to-yellow emitting phosphors (MSi2N2O2:Eu2+, M = Ca, Sr, Ba) are discussed in

  8. Evaluation of characteristics of x-ray phosphors and hybrid scintillators

    International Nuclear Information System (INIS)

    Winter, John M. Jr.; Jones, Thomas S.

    1999-01-01

    Glass x-ray scintillators produce very high resolution images but suffer diminished brightness at x-ray energies below about 150 kV. This produces a loss in effective imaging due to the very low light flux, just at energies where many high resolution applications require the maximum image fidelity. Many phosphors produce substantially more light at these energy levels, but lack the resolution needed for critical industrial applications. A family of hybrid scintillators consisting of a scintillating fiber-optic base coupled to a thin coating of a high resolution phosphor is being developed. To facilitate evaluation of these hybrids and to measure their performance compared to other alternatives, a specialized real time x-ray imaging system was constructed and integrated with a microfocus x-ray source. This imaging system is described, and the results of a program to evaluate the brightness, resolution, and contrast sensitivity of a number of glass scintillators, phosphors, and hybrid imaging screens is presented

  9. Phosphor investigation in the production of Syrian phosphoric acid using Nuclear Magnetic Resonance

    International Nuclear Information System (INIS)

    Al-Hassanieh, O.; Al-Hameish, M.

    2009-06-01

    Nuclear magnetic resonance spectroscopy (NMR) was applied in this work to the industrial process of extraction of uranium from phosphoric acid and to the process of the purification of the phosphoric acid for food proposes. The structural changes of used extraction materials and the organic content of the final product was studied. 13 C , 1 H and 32 P-spectra of all material during the process were recorded. The spectra of the three used extraction materials Bis(2-ethylhexyl Phosphoric Acid)) DEHPA, TriOctyl Phosphine Oxide (TOPO) (C 8 H 1 7) 3 P=O and TriButyl Phosphate (TBP) (C 4 H 9 O) 3 P=O show a partial degradation during the process. The final product ( Phosphoric acid for Food proposes) doesn't contain any organic solvents or extraction material. (author)

  10. Contrast and decay of cathodoluminescence from phosphor particles in a scanning electron microscope.

    Science.gov (United States)

    den Engelsen, Daniel; Harris, Paul G; Ireland, Terry G; Fern, George R; Silver, Jack

    2015-10-01

    Cathodoluminescence (CL) studies are reported on phosphors in a field emission scanning electron microscope (FESEM). ZnO: Zn and other luminescent powders manifest a bright ring around the periphery of the particles: this ring enhances the contrast. Additionally, particles resting on top of others are substantially brighter than underlying ones. These phenomena are explained in terms of the combined effects of electrons backscattered out of the particles, together with light absorption by the substrate. The contrast is found to be a function of the particle size and the energy of the primary electrons. Some phosphor materials exhibit a pronounced comet-like structure at high scan rates in a CL-image, because the particle continues to emit light after the electron beam has moved to a position without phosphor material. Image analysis has been used to study the loss of brightness along the tail and hence to determine the decay time of the materials. The effect of phosphor saturation on the determination of decay times by CL-microscopy was also investigated. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Process for recovering a uranium containing concentrate and purified phosphoric acid from a wet process phosphoric acid containing uranium

    International Nuclear Information System (INIS)

    Weterings, C.A.M.; Janssen, J.A.

    1985-01-01

    A process is claimed for recovering from a wet process phosphoric acid which contains uranium, a uranium containing concentrate and a purified phosphoric acid. The wet process phosphoric acid is treated with a precipitant in the presence of a reducing agent and an aliphatic ketone

  12. Process for recovering a uranium containing concentrate and purified phosphoric acid from a wet process phosphoric acid containing uranium

    Energy Technology Data Exchange (ETDEWEB)

    Weterings, C.A.M.; Janssen, J.A.

    1985-04-30

    A process is claimed for recovering from a wet process phosphoric acid which contains uranium, a uranium containing concentrate and a purified phosphoric acid. The wet process phosphoric acid is treated with a precipitant in the presence of a reducing agent and an aliphatic ketone.

  13. Pretreatment of phosphoric acid for uranium recovery by the wet phosphoric acid process

    International Nuclear Information System (INIS)

    Chern, S.L.P.; Chen, Y.C.L.; Chang, S.S.H.; Kuo, T.S.; Ting, G.C.M.

    1980-01-01

    The proposal deals with reprocessing of phosphoric acid arising from uranium separation according to the wet phosphoric acid process and being intended for recycling. In detail, the sludge will be removed by means of an inclined separating device containing corrugated plates, then the organic impurities are washed out with kerosene in suitable facilities, and the crude phase remaining in the settling tank will be separated from the kerosene in a separating centrifuge. The method has only got low cost of installation. (UWI) [de

  14. A survey of phosphors novel for thermography

    Energy Technology Data Exchange (ETDEWEB)

    Bruebach, J., E-mail: bruebach@ekt.tu-darmstadt.d [Fachgebiet Reaktive Stroemungen und Messtechnik, Center of Smart Interfaces Technische Universitaet Darmstadt, Petersenstrasse 32, 64287 Darmstadt (Germany); Kissel, T. [Fachgebiet Reaktive Stroemungen und Messtechnik, Center of Smart Interfaces Technische Universitaet Darmstadt, Petersenstrasse 32, 64287 Darmstadt (Germany); Frotscher, M. [Eduard-Zintl-Institut fuer Anorganische und Physikalische Chemie, Technische Universitaet Darmstadt, Petersenstrasse 18, 64287 Darmstadt (Germany); Euler, M. [Fachgebiet Reaktive Stroemungen und Messtechnik, Center of Smart Interfaces Technische Universitaet Darmstadt, Petersenstrasse 32, 64287 Darmstadt (Germany); Albert, B. [Eduard-Zintl-Institut fuer Anorganische und Physikalische Chemie, Technische Universitaet Darmstadt, Petersenstrasse 18, 64287 Darmstadt (Germany); Dreizler, A. [Fachgebiet Reaktive Stroemungen und Messtechnik, Center of Smart Interfaces Technische Universitaet Darmstadt, Petersenstrasse 32, 64287 Darmstadt (Germany)

    2011-04-15

    With regard to phosphor thermometry, seven luminescent ceramic materials were synthesised and characterised, namely CaMoO{sub 4}:Eu{sup 3+}, CaTiO{sub 3}:Pr{sup 3+}, LaPO{sub 4}:Eu{sup 3+}, LaVO{sub 4}:Eu{sup 3+}, LiAl{sub 5}O{sub 8}:Fe{sup 3+}, TiMg{sub 2}O{sub 4}:Mn{sup 4+} and ZnGa{sub 2}O{sub 4}:Mn{sup 2+}. In this context, emission spectra and temperature lifetime characteristics are presented. Thus, a survey of phosphors novel for thermography is given in order to encourage further studies and more detailed characterisations of the respective materials. - Research Highlights: Seven phosphor materials novel for thermometry were synthesised. These materials were characterised diffractometrically as well as concerning their emission spectra and lifetime temperature characteristics. The number of phosphor materials characterised for thermometry purposes was extended by seven materials.

  15. Phosphate phosphors for solid-state lighting

    Energy Technology Data Exchange (ETDEWEB)

    Shinde, Kartik N. [N.S. Science and Arts College, Bhadrawati (India). Dept. of Physics; Swart, H.C. [University of the Orange Free State, Bloemfontein (South Africa). Dept. of Physics; Dhoble, S.J. [R.T.M. Nagpur Univ. (India). Dept. of Physics; Park, Kyeongsoon [Sejong Univ., Seoul (Korea, Republic of). Faculty of Nanotechnology and Advanced Materials Engineering

    2012-07-01

    Essential information for students in researchers working towards new and more efficient solid-state lighting. Comprehensive survey based on the authors' long experience. Useful both for teaching and reference. The idea for this book arose out of the realization that, although excellent surveys and a phosphor handbook are available, there is no single source covering the area of phosphate based phosphors especially for lamp industry. Moreover, as this field gets only limited attention in most general books on luminescence, there is a clear need for a book in which attention is specifically directed toward this rapidly growing field of solid state lighting and its many applications. This book is aimed at providing a sound introduction to the synthesis and optical characterization of phosphate phosphor for undergraduate and graduate students as well as teachers and researchers. The book provides guidance through the multidisciplinary field of solid state lighting specially phosphate phosphors for beginners, scientists and engineers from universities, research organizations, and especially industry. In order to make it useful for a wide audience, both fundamentals and applications are discussed, together.

  16. doped LiMgPO4 phosphor

    Indian Academy of Sciences (India)

    attention because of their remarkable luminescence proper- ties and .... Figure 1. (a) X-ray diffraction patterns of LiMgPO4:Tb3+ phosphor and (b) standard data. ICDD file. .... ground signal which affects the signal to noise ratio [17]. MDD was ...

  17. Comparison of stimulable phosphor technology and conventional screen-film technology in pediatric scoliosis

    International Nuclear Information System (INIS)

    Stringer, D.A.; Cairns, R.A.; Poskitt, K.J.; Bray, H.; Milner, R.; Kennedy, B.

    1994-01-01

    One hundred consecutive patients being investigated for scoliosis were studied using a double cassette containing a conventional film screen and a stimulable phosphor plate. The images were separated, randomised and scored thrice by three radiologists for anatomic structure visualisation. The exposure to the plate and film and repeat rate were measured. Scoliosis angles were comparable on both sets of images, however, visualisation of vertebrae, vertebral end plates, pedicles, spinous processes and other structures were significantly improved (p < 0.0001). Intra- and inter-observer reliability was high with good intraclass correlation. There was a 40% potential exposure reduction, and retakes were decreased from 3 to 0%. We conclude that stimulable phosphor images give better anatomic structure visualisation with potential radiation exposure reduction and lower repeat rate. (orig.)

  18. High Extraction Phosphors for Solid State Lighting

    Energy Technology Data Exchange (ETDEWEB)

    Summers, Chris [Phosphortech Corporation, Kennesaw, GA (United States); Menkara, Hisham [Phosphortech Corporation, Kennesaw, GA (United States); Wagner, Brent [Phosphortech Corporation, Kennesaw, GA (United States)

    2011-09-01

    We have developed high-index, high efficiency bulk luminescent materials and novel nano-sized phosphors for improved solid-state white LED lamps. These advances can potentially contribute to reducing the loss in luminous efficiencies due to scattering, re-absorption, and thermal quenching. The bulk and nanostructured luminescent materials investigated are index matched to GaN and have broad and size-tunable absorption bands, size and impurity tuned emission bands, size-driven elimination of scattering effects, and a separation between absorption and emission bands. These innovations were accomplished through the use of novel synthesis techniques suitable for high volume production for LED lamp applications. The program produced a full-color set of high quantum yield phosphors with high chemical stability. In the bulk phosphor study, the ZnSeS:Cu,Ag phosphor was optimized to achieve >91% efficiency using erbium (Er) and other activators as sensitizers. Detailed analysis of temperature quenching effects on a large number of ZnSeS:Cu,Ag,X and strontium- and calcium-thiogallate phosphors lead to a breakthrough in the understanding of the anti-quenching behavior and a physical bandgap model was developed of this phenomena. In a follow up to this study, optimized phosphor blends for high efficiency and color performance were developed and demonstrated a 2-component phosphor system with good white chromaticity, color temperature, and high color rendering. By extending the protocols of quantum dot synthesis, large nanocrystals, greater than 20 nm in diameter were synthesized and exhibited bulk-like behavior and blue light absorption. The optimization of ZnSe:Mn nanophosphors achieved ~85% QE The limitations of core-shell nanocrystal systems were addressed by investigating alternative deltadoped structures. To address the manufacturability of these systems, a one-pot manufacturing protocol was developed for ZnSe:Mn nanophosphors. To enhance the stability of these material

  19. Recuperation of uranium from phosphoric acid

    International Nuclear Information System (INIS)

    Cordero, G.; Jodra, L.G.; Otero, J.L.; Josa, J.M.

    1977-01-01

    The Spanish capacity for phosphoric acid production is 500.000 t P 2 O 5 /yr. This acid has an average concentration of 365 g U 3 O 8 / t P 2 O 5 . Therefore about 180 t U 3 O 8 /yr are dissolved. In 1969, the Junta de Energia Nuclear (JEN) developed, in bench scale, a solvent extraction process to recover the uranium from the phosphoric acid. The solvent used was a synergistic mixture of D2EHPA and TOPO. The results were very promising with good recovery and very high quality for the uranium concentrate. Later, the J.E.N. continued the studies in a pilot plant scale. For this purpose, was built an experimental facility in Huelva; it can treat about 7 cu. m/day of brown acid. Fosforico Espanol, S.A. (FESA) collaborated in the studies and agreed to setting up these installations in their factory. They also provided fresh phosphoric acid for the tests. In this pilot plant we studied the following stages: a) Clarification and conditioning of the phosphoric acid; b) Uranium extraction followed by stripping in a reducing medium; c) Purification by extraction and washing; d) Obtention of the concentrate by stripping with ammonia and CO 2 gas, followed by crystallization of the ammonium uranyl tricarbonate (AUT); and e) Calcination of the concentrate to decompose the AUT to uranium oxides. The results confirmed the laboratory test data. Recuperation levels were between 85 and 90%. The AUT calcined at 550 0 C. gave a product with 96-98% U 3 O 8 . In view of the pilot plant results we have prepared a black book for an industrial plant to treat about 3700 cu. m/day of phosphoric acid. At the present time the financial aspects of this installation are being studied [es

  20. Persistent luminescence and thermoluminescence of UV/VIS -irradiated SrAl2O4: Eu2+, Dy3+ phosphor

    International Nuclear Information System (INIS)

    Pereyda-Pierre, C.; Meléndrez, R.; García, R.; Pedroza-Montero, M.; Barboza-Flores, M.

    2011-01-01

    The persistent luminescence and thermoluminescence properties of SrAl 2 O 4 : Eu 2+ , Dy 3+ phosphors excited with UV–VIS light in the 200–500 nm region were investigated. The thermoluminescence glow curve was found to be composed of peaks around 70, 125 and 245 °C. The persistent luminescence and thermoluminescence excitation spectra exhibited a broad band around 300–500 nm centered at 400 and 420 nm respectively. A linear behavior of the integrated thermoluminescence intensity and persistent luminescence versus irradiation time was found for the first 60 s. The charge detrapping from the 70 °C trapping levels was the major contributor to the observed persistent luminescence at room temperature. The SrAl 2 O 4 : Eu 2+ , Dy 3+ phosphors have suitable properties to be applied as storage and persistent luminescence UV–VIS irradiation dose phosphor. -- Highlights: ► SrAl 2 O 4 :Eu 2+ , Dy 3+ persistent luminescence and thermoluminescence was measured. ► The phosphor was irradiated with UV–VIS photons in the 200–500 nm wavelength range. ► SrAl 2 O 4 :Eu 2+ , Dy 3+ behaves adequately as persistent and storage UV–VIS dosimeter. ► The persistent luminescence dosimetry does not require heat or light stimulation.

  1. Energy Storage.

    Science.gov (United States)

    Eaton, William W.

    Described are technological considerations affecting storage of energy, particularly electrical energy. The background and present status of energy storage by batteries, water storage, compressed air storage, flywheels, magnetic storage, hydrogen storage, and thermal storage are discussed followed by a review of development trends. Included are…

  2. Uranium recovery from wet process phosphoric acid

    International Nuclear Information System (INIS)

    1980-01-01

    In the field of metallurgy, specifically processes for recovering uranium from wet process phosphoric acid solution derived from the acidulation of uraniferous phosphate ores, problems of imbalance of ion exchange agents, contamination of recycled phosphoric acid with process organics and oxidizing agents, and loss and contamination of uranium product, are solved by removing organics from the raffinate after ion exchange conversion of uranium to uranous form and recovery thereof by ion exchange, and returning organics to the circuit to balance mono and disubstituted ester ion exchange agents; then oxidatively stripping uranium from the agent using hydrogen peroxide; then after ion exchange recovery of uranyl and scrubbing, stripping with sodium carbonate and acidifying the strip solution and using some of it for the scrubbing; regenerating the sodium loaded agent and recycling it to the uranous recovery step. Economic recovery of uranium as a by-product of phosphate fertilizer production is effected. (author)

  3. The Influence of Phosphor and Binder Chemistry on the Aging Characteristics of Remote Phosphor Products

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Lynn; Yaga, Robert; Lamvik, Michael; Mills, Karmann; Fletcher, B.

    2017-06-30

    The influence of phosphor and binder layer chemistries on the lumen maintenance and color stability of remote phosphor disks were examined using wet high-temperature operational lifetime testing (WHTOL). As part of the experimental matrix, two different correlated color temperature (CCT) values, 2700 K and 5000 K, were studied and each had a different binder chemistry. The 2700 K samples used a urethane binder whereas the 5000 K samples used an acrylate binder. Experimental conditions were chosen to enable study of the binder and phosphor chemistries and to minimize photo-oxidation of the polycarbonate substrate. Under the more severe WHTOL conditions of 85°C and 85% relative humidity (RH), absorption in the binder layer significantly reduced luminous flux and produced a blue color shift. The milder WHTOL conditions of 75°C and 75% RH, resulted in chemical changes in the binder layer that may alter its index of refraction. As a result, lumen maintenance remained high, but a slight yellow shift was found. The aging of remote phosphor products provides insights into the impact of materials on the performance of phosphors in an LED lighting system.

  4. [Change traits of phosphorous consumption structure in China and their effects on environmental phosphorous loads].

    Science.gov (United States)

    Ma, Dun-Chao; Hu, Shan-Ying; Chen, Ding-Jiang; Li, You-Run

    2012-04-01

    Substance flow analysis was used to construct a model to analyze change traits of China's phosphorous (P) consumption structure from 1980 to 2008 and their influences on environmental phosphorous loads, then the correlation between several socioeconomic factors and phosphorous consumption pollution was investigated. It is found that phosphorous nutrient inputs of urban life and rural life on a per capita level climbed to 1.20 kg x a(-1) and 0.99 kg x a(-1) from 0.83 kg x a(-1) and 0.75 kg x a(-1) respectively, but phosphorous recycling ratios of urban life fell to 15.6% from 62.6%. P inputs of animal husbandry and planting also kept increasing, but the recycling ratio of the former decreased from 67.5% to 40.5%, meanwhile much P input of the latter was left in agricultural soil. Correlation coefficients were all above 0.90, indicating that population, urbanization level, development levels of planting and animal husbandry were important incentives for P consumption pollution in China. Environmental Kuznets curve showed that China still stayed in the early development stage, promoting economic growth at an expense of environmental quality. This study demonstrates that China's P consumption system is being transformed into a linear and open structure, and that P nutrient loss and environmental P loads increase continually.

  5. Ultraviolet dosimetry using thermoluminescent phosphors - an update

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    1998-04-01

    Intrinsic response of various thermoluminescent (TL) materials such as CaSO 4 (Dy, Eu, Mn, Sm, Tb, or Tm), LiF (Mg, Cu, P), Mg 2 SiO 4 :Tb, CaF 2 :Dy, CaF 2 :Tb, ThO 2 :Tb and Al 2 O 3 (Si, Ti); cathodoluminescent phosphors Y 3 Al 5 O 12 :Ce, Y 3 Al 5 O 12 :Tb and Y(V,P)O 4 :Eu; and fluorescent lamp phosphors calcium halophosphate (Mn,Sb) and Ce Mg aluminate (Eu, Tb) to ultraviolet (UV) radiations has been studied. Intrinsic TL response of most of the phosphors is rate (radiant flux) dependent. For the first time, UV response of the materials is reported for a fixed total radiant energy (total UV dose), at a single radiant flux (260 μW.cm -2 ), for an appropriate comparison. A wide range of UV sensitivity is observed. Studies conducted using UV radiation from two unfiltered low pressure mercury lamps show significant differences in glow curves, as compared to those obtained with nearly monochromatic UV radiations. Photons of wavelength 365 nm induce bleaching of TL induced by 254 nm photons, in most of the materials. Sequential/tandem exposures to 254 nm and 365 nm photons have yielded new but alarming results in CaF 2 :Tb. Preferential induction and bleaching of specific TL glow peaks by 365 nm and 254 nm photons are interesting characteristics discovered in CaSO 4 :Eu. Photoluminescence studies of Tb 3+ and Eu 3+ activated phosphors have augmented the inferences drawn from the bleaching effects produced by 365 nm photons. Earlier work carried out on phototransferred thermoluminescence of CaSO 4 :Dy-teflon dosimeters, TLD-100, Mg 2 SiO 4 :Tb and Al 2 O 3 (Si,Ti) has also been reviewed. (author)

  6. Phosphor for thermoluminescent type radiation dosimeter

    International Nuclear Information System (INIS)

    Nada, N.; Yamashita, T.

    1975-01-01

    This has the accumulation effect of radiation energy and is mainly used as the element for thermoluminescent type radiation dosimeters. It has as the principal constituent a phosphor consisting of calcium sulfate as the principal constituent and other impurity elements such as dysprosium, thulium and the like. It is more sensitive by the order of 1 to 2 or more figures than the conventional ones and is excellent in the retention of absorbed radiation energy. (U.S.)

  7. Thermoluminescence of calcium-based phosphors

    International Nuclear Information System (INIS)

    Sunta, C.M.

    1985-01-01

    The paper reviews the thermoluminescence (TL) properties of calcium fluoride, calcium sulphate and calcium carbonate phosphors. In the case of the calcium fluoride mineral phosphor the main emitter of TL is the cerium impurity. Based on the TL emission spectra, two types of Ce 3+ centres can be easily distinguished; those associated with O 2- compensating ion and those which have either no local compensators or are associated with F - interstitial ions at the adjacent vacant body centre position. The spectra undergo remarkable changes at high doses. Such changes are associated with the probabilities of charge trapping at different types of traps and also with the probabilities of recombination at different types of luminescent centres. Some of the traps and recombination centres are spatially associated while others are distributed randomly. In calcium carbonate mineral, Mn 2+ is invariably the emitting impurity. Mn 2+ can be used as an efficient dopant for TL emission in all the three calcium based TL phosphors. A co-dopant like Ce 3+ intensifies the luminescence yield from Mn 2+ . Models of different types of electron and hole trapping centres are given. (author)

  8. Radioisotope decontamination of X-ray detector. Photostimulable phosphor plate

    International Nuclear Information System (INIS)

    Onuma, Yoji; Hayashi, Michiko; Hayashi, Hiroaki; Nishihara, Sadamitsu

    2012-01-01

    We tried to remove contamination of radioisotope (RI) for an X-ray detector (photostimulable phosphor plate; IP) and verified that our procedure suggested by Nishihara et al. was effective for decontamination. The procedure was as follows. First, the IP was kept for approximately twelve hours, and then it was processed [image (A)] as well as a clinical processing mode. Second, using a wet-type chemical wiper, we scavenged the IP to remove the adhered RI on its surface. Then, once again, the IP was kept for approximately fifteen hours and processed [image (B)] in order to check an effect of decontamination. Finally, the two images of (A) and (B) were analyzed using ImageJ, which can be downloaded as a free software, and a percentage of removal was calculated. The procedure was applied to two IPs using the Fuji computed tomography (FCR) 5501 plus. In the present case, the percentage of removal was approximately 96%. The removed radioisotopes in the chemical wipers were analyzed by Ge detector. Then, 134 Cs and 137 Cs were found with activities of 2.9 4.3 Bq and 3.5 5.2 Bq, respectively. For three months after that, we cannot see black spots on the IPs owing to the contamination of the RI and there are no defects caused by decontamination using a wet-type chemical wiper. (author)

  9. Photovoltaic Performance Characterization of Textured Silicon Solar Cells Using Luminescent Down-Shifting Eu-Doped Phosphor Particles of Various Dimensions.

    Science.gov (United States)

    Ho, Wen-Jeng; Deng, Yu-Jie; Liu, Jheng-Jie; Feng, Sheng-Kai; Lin, Jian-Cheng

    2017-01-01

    This paper reports on efforts to enhance the photovoltaic performance of textured silicon solar cells through the application of a layer of Eu-doped silicate phosphor with particles of various dimensions using the spin-on film technique. We examined the surface profile and dimensions of the Eu-doped phosphors in the silicate layer using optical microscopy with J-image software. Optical reflectance, photoluminescence, and external quantum efficiency were used to characterize the luminescent downshifting (LDS) and light scattering of the Eu-doped silicate phosphor layer. Current density-voltage curves under AM 1.5G simulation were used to confirm the contribution of LDS and light scattering produced by phosphor particles of various dimensions. Experiment results reveal that smaller phosphor particles have a more pronounced effect on LDS and a slight shading of incident light. The application of small Eu-doped phosphor particles increased the conversion efficiency by 9.2% (from 12.56% to 13.86%), far exceeding the 5.6% improvement (from 12.54% to 13.32%) achieved by applying a 250 nm layer of SiO₂ and the 4.5% improvement (from 12.37% to 12.98%) observed in cells with large Eu-doped phosphor particles.

  10. Investigation of saturation effects in ceramic phosphors for laser lighting

    DEFF Research Database (Denmark)

    Krasnoshchoka, Anastasiia; Thorseth, Anders; Dam-Hansen, Carsten

    2017-01-01

    We report observation of saturation effects in a Ce:LuAG and Eu-doped nitride ceramic phosphor for conversion of blue laser light for white light generation. The luminous flux from the phosphors material increases linearly with the input power until saturation effects limit the conversion....... It is shown, that the temperature of the phosphor layer influences the saturation power level and the conversion efficiency. It is also shown that the correlated color temperature (CCT), phosphor conversion efficiency and color rendering index (CRI) are dependent both on incident power and spot size diameter...... of the illumination. A phosphor conversion efficiency up to 140.8 lm/W with CRI of 89.4 was achieved. The saturation in a ceramic phosphor, when illuminated by high intensity laser diodes, is estimated to play the main role in limiting the available luminance from laser based lighting systems....

  11. Re-processing CRT phosphors for mercury-free applications

    International Nuclear Information System (INIS)

    Dexpert-Ghys, Jeannette; Regnier, Sophie; Canac, Sophie; Beaudette, Tristan; Guillot, Philippe; Caillier, Bruno; Mauricot, Robert; Navarro, Julien; Sekhri, Salem

    2009-01-01

    This study is part of an operation in the framework of treatment and revalorization of IEEE (Informatics, Electronics and related) wastes. It aims to recover the active phosphors in cathode ray tubes (CRTs) and to re-cycle these powders by appropriate treatments as phosphors for mercury-free applications such as plasma display panels, flat lamps, advertising and lighting. The studied waste comes from a large panel of CRTs from any supplier. Several thermo-chemical treatments have been investigated. The removal of zinc sulfide-based phosphors and the recovery of a red phosphor Y 2 O 3 :Eu 3+ has been achieved by one (basic attack) route. The photoluminescence efficiency under VUV excitation of the obtained powders is at most 30% that of a commercial phosphor. The second route (acid attack) appears less promising. It has been established that silicate-based impurities could prevent isolating the yttrium based phosphor.

  12. Re-processing CRT phosphors for mercury-free applications

    Energy Technology Data Exchange (ETDEWEB)

    Dexpert-Ghys, Jeannette, E-mail: jdexpert@cemes.f [CEMES, 29 rue Jeanne Marvig, BP 94347, 31055 Toulouse cedex 4 (France); Regnier, Sophie; Canac, Sophie [ICAM, 75 avenue de Grande Bretagne, 31300 Toulouse (France); Beaudette, Tristan; Guillot, Philippe; Caillier, Bruno [DPHE, Universite Jean Francois Champollion, place de Verdun, 81012 Albi cedex 9 (France); Mauricot, Robert; Navarro, Julien [CEMES, 29 rue Jeanne Marvig, BP 94347, 31055 Toulouse cedex 4 (France); Sekhri, Salem [ENVOI, Cheminement Glueck, 31100 Toulouse (France)

    2009-12-15

    This study is part of an operation in the framework of treatment and revalorization of IEEE (Informatics, Electronics and related) wastes. It aims to recover the active phosphors in cathode ray tubes (CRTs) and to re-cycle these powders by appropriate treatments as phosphors for mercury-free applications such as plasma display panels, flat lamps, advertising and lighting. The studied waste comes from a large panel of CRTs from any supplier. Several thermo-chemical treatments have been investigated. The removal of zinc sulfide-based phosphors and the recovery of a red phosphor Y{sub 2}O{sub 3}:Eu{sup 3+} has been achieved by one (basic attack) route. The photoluminescence efficiency under VUV excitation of the obtained powders is at most 30% that of a commercial phosphor. The second route (acid attack) appears less promising. It has been established that silicate-based impurities could prevent isolating the yttrium based phosphor.

  13. Can direct electron detectors outperform phosphor-CCD systems for TEM?

    Energy Technology Data Exchange (ETDEWEB)

    Moldovan, G; Li, X; Kirkland, A [Department of Materials, University of Oxford, Parks Road, Oxford, 0X1 3PH (United Kingdom)], E-mail: grigore.moldovan@materials.ox.ac.uk

    2008-08-15

    A new generation of imaging detectors is being considered for application in TEM, but which device architectures can provide the best images? Monte Carlo simulations of the electron-sensor interaction are used here to calculate the expected modulation transfer of monolithic active pixel sensors (MAPS), hybrid active pixel sensors (HAPS) and double sided Silicon strip detectors (DSSD), showing that ideal and nearly ideal transfer can be obtained using DSSD and MAPS sensors. These results highly recommend the replacement of current phosphor screen and charge coupled device imaging systems with such new directly exposed position sensitive electron detectors.

  14. Medical Imaging 4: Image formation

    International Nuclear Information System (INIS)

    Schneider, R.H.

    1990-01-01

    This book contains papers relating to the 1990 meeting of The International Society for Optical Engineering. Included are the following papers: Effect of protective layer on Resolution Properties of Photostimulable Phosphor Detector for Digital Radiographic System, Neural Network Scatter Correction Technique for Digital Radiography, Use of Computer Radiography for Portal Imaging

  15. ToF-SIMS images and spectra of biomimetic calcium silicate-based cements after storage in solutions simulating the effects of human biological fluids

    Science.gov (United States)

    Torrisi, A.; Torrisi, V.; Tuccitto, N.; Gandolfi, M. G.; Prati, C.; Licciardello, A.

    2010-01-01

    ToF-SIMS images were obtained from a section of a tooth, obturated by means of a new calcium-silicate based cement (wTCF) after storage for 1 month in a saline solutions (DPBS), in order to simulate the body fluid effects on the obturation. Afterwards, ToF-SIMS spectra were obtained from model samples, prepared by using the same cement paste, after storage for 1 month and 8 months in two different saline solutions (DPBS and HBSS). ToF-SIMS spectra were also obtained from fluorine-free cement (wTC) samples after storage in HBSS for 1 month and 8 months and used for comparison. It was found that the composition of both the saline solution and the cement influenced the composition of the surface of disks and that longer is the storage greater are the differences. Segregation phenomena occur both on the cement obturation of the tooth and on the surface of the disks prepared by using the same cement. Indirect evidences of formation of new crystalline phases are supplied.

  16. Thermomchromic Reaction-Induced Reversible Upconversion Emission Modulation for Switching Devices and Tunable Upconversion Emission Based on Defect Engineering of WO3:Yb3+,Er3+ Phosphor.

    Science.gov (United States)

    Ruan, Jiufeng; Yang, Zhengwen; Huang, Anjun; Zhang, Hailu; Qiu, Jianbei; Song, Zhiguo

    2018-05-02

    Reversible luminescence modulation of upconversion phosphors has the potential applications as photoswitches and optical memory and data storage devices. Previously, the photochromic reaction was extensively used for the realization of reversible luminescence modulation. It is very necessary to develop other approaches such as thermomchromic reaction to obtain the reversible upconversion luminescence modulation. In this work, the WO 3 :Yb 3+ ,Er 3+ phosphors with various colors were prepared at various temperatures, exhibiting tunable upconversion luminescence attributed to the formation of oxygen vacancies in the host. Upon heat treatment in the reducing atmosphere or air, the WO 3 :Yb 3+ ,Er 3+ phosphors show a reversible thermomchromic property. The reversible upconversion luminescence modulation of WO 3 :Yb 3+ ,Er 3+ phosphors was observed based on thermomchromic reaction. Additionally, the upconversion luminescence modulation is maintained after several cycles, indicating its excellent stability. The WO 3 :Yb 3+ ,Er 3+ phosphors with reversible upconversion luminescence and excellent reproducibility have potential applications as the photoswitches and optical memory and data storage devices.

  17. Counter current extraction of phosphoric acid: Food grade acid production

    International Nuclear Information System (INIS)

    Shlewit, H.; AlIbrahim, M.

    2009-01-01

    Extraction, scrubbing and stripping of phosphoric acid from the Syrian wet-phosphoric acid was carried out using Micro-pilot plant of mixer settler type of 8 l/h capacity. Tributyl phosphate (TBP)/di-isopropyl ether (DIPE) in kerosene was used as extractant. Extraction and stripping equilibrium curves were evaluated. The number of extraction and stripping stages to achieve the convenient and feasible yield was determined. Detailed flow sheet was suggested for the proposed continuous process. Data obtained include useful information for the design of phosphoric acid extraction plant. The produced phosphoric acid was characterized using different analytical techniques. (author)

  18. Uranium recovery from wet-process phosphoric acid

    International Nuclear Information System (INIS)

    McCullough, J.F.; Phillips, J.F. Jr.; Tate, L.R.

    1979-01-01

    A method of recovering uranium from wet-process phosphoric acid is claimed where the acid is treated with a mixture of an ammonium salt or ammonia, a reducing agent, and then a miscible solvent. Solids are separated from the phosphoric acid liquid phase. The solid consists of a mixture of metal phosphates and uranium. It is washed free of adhering phosphoric acid with fresh miscible solvent. The solid is dried and dissolved in acid whereupon uranium is recovered from the solution. Miscible solvent and water are distilled away from the phosphoric acid. The distillate is rectified and water discarded. All miscible solvent is recovered for recycle. 5 claims

  19. Method of recovering phosphoric acid type decontaminating electrolytes by electrodeposition

    International Nuclear Information System (INIS)

    Sasaki, Takashi; Wada, Koichi; Kobayashi, Toshio.

    1985-01-01

    Purpose: To recoving phosphoric acid type highly concentrated decontaminating liquid used for the electrolytic decontamination of contaminated equipments, components, etc in nuclear power plants or the like through electrodeposition by diaphragm electrolysis. Method: Before supplying phosphoric acid decontaminating liquid at high concentration used in the electrolytic decontaminating step to an electrodeposition recovering tank, phosphoric acid in the decontaminating electrolyte is extracted with solvents and decomposed liquid extracts (electrolyte reduced with the phosphoric acid component) are supplied to the cathode chamber of the electrodeposition recovering tank, where phosphoric acid is back-extracted with water from the solvents after extraction of phosphoric acid. Then, the back-extracted liquids (aqueous phosphoric acid solution scarcely containing metal ions) are sent to the anode chamber of the electrodeposition recovering tank. Metal ions in the liquid are captured by electrodeposition in the cathode chamber, as well as phosphoric acid in the liquids is concentrated to the initial concentration of the electrolyte in the anode chamber for reuse as the decontaminating electrolyte. As the phosphoric acid extracting agent used in the electrodeposition recovering step for the decontaminating electrolyte, water-insoluble and non-combustible tributyl phosphate (TBP) is most effective. (Horiuchi, T.)

  20. Point defect engineering strategies to retard phosphorous diffusion in germanium

    KAUST Repository

    Tahini, H. A.; Chroneos, Alexander I.; Grimes, Robin W.; Schwingenschlö gl, Udo; Bracht, Hartmut A.

    2013-01-01

    The diffusion of phosphorous in germanium is very fast, requiring point defect engineering strategies to retard it in support of technological application. Density functional theory corroborated with hybrid density functional calculations are used to investigate the influence of the isovalent codopants tin and hafnium in the migration of phosphorous via the vacancy-mediated diffusion process. The migration energy barriers for phosphorous are increased significantly in the presence of oversized isovalent codopants. Therefore, it is proposed that tin and in particular hafnium codoping are efficient point defect engineering strategies to retard phosphorous migration. © the Owner Societies 2013.

  1. Tm3+ activated lanthanum phosphate: a blue PDP phosphor

    International Nuclear Information System (INIS)

    Rao, R.P.

    2005-01-01

    Plasma display panels (PDPs) are gaining attention due to their high performance and scalability as a medium for large format TVs. The performance and life of a PDP strongly depends upon the nature of phosphors. Currently, Eu 2+ activated barium magnesium aluminate (BAM) is being used as a blue component. Because of its low life, efforts are being made to explore new blue emitting phosphors. One of the alternatives to BAM is Tm 3+ activated lanthanum phosphate (LPTM) phosphor. LPTM phosphor samples are prepared by a solid-state as well as sol-gel process in presence of flux. The phosphor of the present investigation, having uniform and spherical shape particles in the range of 0.1-2 μm, is appropriate for thin phosphor screens required for PDP applications. It exhibits a narrow band emission in the blue region, peaking at 452 nm and also a number of narrow bands in the UV region when excited by 147 and 173 nm radiation from a xenon gas mixture. Various possible transitions responsible for UV and visible emission from Tm 3+ ion are presented. These phosphors also exhibit good color saturation and better stability when excited with VUV radiation. To achieve higher brightness, they are blended with other UV excited blue emitting phosphors such as BAM. Results related to morphology, excitation, after glow decay, emission and degradation of these phosphors in the powder form as well as in plasma display panels are presented and discussed

  2. Interim solidification of SRP waste with silica, bentonite, or phosphoric acid

    International Nuclear Information System (INIS)

    Thompson, G.H.

    1976-03-01

    One option for interim waste management at the Savannah River Plant is in-tank solidification of the liquid waste solutions. This would reduce the mobility of these highly radioactive solutions until techniques for their long-term immobilization and storage are developed and implemented. Interim treatments must permit eventual retrieval of waste and subsequent incorporation into a high-integrity form. This study demonstrated the solidification of simulated alkaline waste solutions by reaction with silica, bentonite, and phosphoric acid. Alkaline waste can be solidified by reaction with silica gel, silica flour, or sodium silicate solution. Solidified products containing waste salt can be retrieved by slurrying with water. Alkaline supernate (solution in equilibrium with alkaline sludge in SRP waste tanks) can be solidified by reaction with bentonite to form cancrinite powder. The solidified waste can be retrieved by slurrying with water. Alkaline supernate can be solidified by partial evaporation and reaction with phosphoric acid. Water is incorporated into hydrated complexes of trisodium phosphate. The product is soluble, but actual plant waste would not solidify completely because of decay heat. Reaction of simulated alkaline waste solutions with silica gel, silica flour, or bentonite increases the volume by a factor of approximately 6 over that of evaporated waste; reaction with phosphoric acid results in a volume 1.5 times that of evaporated waste. At present, the best method for in-tank solidification is by evaporation, a method that contributes no additional solids to the waste and does not compromise any waste management options

  3. Determination of surface temperatures in combustion environments using thermographic phosphors; Wandtemperaturmessungen in Verbrennungsumgebungen mithilfe thermographischer Phosphore

    Energy Technology Data Exchange (ETDEWEB)

    Bruebach, J.; Kissel, T. [TU Darmstadt (Germany). FG Energie- und Kraftwerkstechnik; Dreizler, A. [TU Darmstadt (Germany). FG Reaktive Stroemungen und Messtechnik

    2009-07-01

    A phosphor thermometry system was characterised with regard to all sources of systematic errors. Exemplary, the point measurement of a surface temperature and the determination of wall-normal temperature gradients within an optically accessible combustion chamber are outlined. Furthermore, the temporal temperature characteristic at the quartz ring of an optically accessible engine is presented. (orig.)

  4. Uranium recovery from wet process phosphoric acid

    International Nuclear Information System (INIS)

    Carrington, O.F.; Pyrih, R.Z.; Rickard, R.S.

    1981-01-01

    Improvement in the process for recovering uranium from wetprocess phosphoric acid solution derived from the acidulation of uraniferous phosphate ores by the use of two ion exchange liquidliquid solvent extraction circuits in which in the first circuit (A) the uranium is reduced to the uranous form; (B) the uranous uranium is recovered by liquid-liquid solvent extraction using a mixture of mono- and di-(Alkyl-phenyl) esters of orthophosphoric acid as the ion exchange agent; and (C) the uranium oxidatively stripped from the agent with phosphoric acid containing an oxidizing agent to convert uranous to uranyl ions, and in the second circuit (D) recovering the uranyl uranium from the strip solution by liquid-liquid solvent extraction using di(2ethylhexyl)phosphoric acid in the presence of trioctylphosphine oxide as a synergist; (E) scrubbing the uranium loaded agent with water; (F) stripping the loaded agent with ammonium carbonate, and (G) calcining the formed ammonium uranyl carbonate to uranium oxide, the improvement comprising: (1) removing the organics from the raffinate of step (B) before recycling the raffinate to the wet-process plant, and returning the recovered organics to the circuit to substantially maintain the required balance between the mono and disubstituted esters; (2) using hydogren peroxide as the oxidizing agent in step (C); (3) using an alkali metal carbonate as the stripping agent in step (F) following by acidification of the strip solution with sulfuric acid; (4) using some of the acidified strip solution as the scrubbing agent in step (E) to remove phosphorus and other impurities; and (5) regenerating the alkali metal loaded agent from step (F) before recycling it to the second circuit

  5. Concentration and wavelength dependent frequency downshifting photoluminescence from a Tb3+ doped yttria nano-phosphor: A photochromic phosphor

    Science.gov (United States)

    Yadav, Ram Sagar; Rai, Shyam Bahadur

    2018-03-01

    In this article, the Tb3+ doped Y2O3 nano-phosphor has been synthesized through solution combustion method. The structural measurements of the nano-phosphor have been carried out by X-ray diffraction (XRD), scanning electron microscopy (SEM) and transmission electron microscopy (TEM) techniques, which reveal nano-crystalline nature. The Fourier transform infrared (FTIR) measurements reveal the presence of different molecular species in the nano-phosphor. The UV-Vis-NIR absorption spectrum of the nano-phosphor shows large number of bands due to charge transfer band (CTB) and 4f-4f electronic transitions of Tb3+ ion. The Tb3+ doped Y2O3 nano-phosphor emits intense green downshifting photoluminescence centered at 543 nm due to 5D4 → 7F5 transition on excitation with 350 nm. The emission intensity of the nano-phosphor is optimized at 1.0 mol% concentration of Tb3+ ion. When the as-synthesized nano-phosphor is annealed at higher temperature the emission intensity of the nano-phosphor enhances upto 5 times. The enhancement in the emission intensity is due to an increase in crystallinity of the nano-phosphor, reduction in surface defects and optical quenching centers. The CIE diagram reveals that the Tb3+ doped nano-phosphor samples show the photochromic nature (color tunability) with a change in the concentration of Tb3+ ion and excitation wavelength. The lifetime measurement indicates an increase in the lifetime for the annealed sample. Thus, the Tb3+ doped Y2O3 nano-phosphor may be used in photochromic displays and photonic devices.

  6. Analysis of phosphoric ore bacterial and eucaryal microbial diversity ...

    African Journals Online (AJOL)

    These findings provided new opportunities into phosphoric ore microbiology that could be useful in biological system removing waste gases generated from the phosphoric industry. Keywords: Microbial community, bacteria, archaea, eucarya, mining residue. African Journal of Biotechnology, Vol 13(30) 3023-3029 ...

  7. World wide IFC phosphoric acid fuel cell implementation

    Energy Technology Data Exchange (ETDEWEB)

    King, J.M. Jr

    1996-04-01

    International Fuel Cells, a subsidary of United technologies Corporation, is engaged in research and development of all types of fuel cell technologies and currently manufactures alkaline fuel cell power plants for the U.S. manned space flight program and natural gas fueled stationary power plants using phosphoric acid fuel cells. This paper describes the phosphoric acid fuel cell power plants.

  8. Separation of rare earths from solutions of phosphoric acid

    International Nuclear Information System (INIS)

    Jones, E.A.

    1977-01-01

    Rare earths are separated from 6M phosphoric acid by adsorption onto cation resin BIORAD AG50W-X8. The phosphoric acid is then washed from the column, and the rare earths are eluted with 4M hydrochloric acid

  9. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  10. Photoluminescence of phosphors for PDP with VUV excitation

    International Nuclear Information System (INIS)

    Lu, H.-C.; Chen, H.-K.; Tseng, T.-Y.; Kuo, W.-L.; Alam, M.S.; Cheng, B.-M.

    2005-01-01

    In a plasma display panel (PDP) He-Xe or Ne-Xe gaseous mixtures are subjected to electric discharge between two glass panels, so to generate VUV light. Red, green and blue phosphors absorb this VUV radiation and re-radiate the energy as visible light to produce the colors that appear on the screen. The phosphor plays an important role in the working of a PDP. To improve the efficiency of phosphors, we have established a photoluminescence end station coupled to the beam line of a synchrotron to study the luminescence of PDP phosphors. This luminescence is analyzed with a 0.32 m monochromator having maximum resolution 0.04 nm, and is monitored with a photomultiplier tube operated in a photon-counting mode. Preliminary data demonstrate the powerful performance of this end-station for studying PDP phosphors

  11. Process for winning uranium from wet process phosphoric acid

    International Nuclear Information System (INIS)

    1980-01-01

    A process is described for winning uranium from wet process phosphoric acid by means of liquid-liquid extraction with organic phosphoric acid esters. The process is optimised by keeping the sulphate percentage in the phosphoric acid below 2% by weight, and preferably below 0.6% by weight, as compared to P 2 O 5 in the phosphoric acid. This is achieved by adding an excess of Ba and/or Ca carbonate or sulfide solution and filtering off the formed calcium and/or barium sulphate precipitates. Solid KClO 3 is then added to the filtrate to oxidise U 4+ to U 6+ . The normal extraction procedure using organic phosphoric esters as extraction liquid, can then be applied. (Th.P.)

  12. Thermal and Electrical Conductivity Measurements of CDA 510 Phosphor Bronze

    Science.gov (United States)

    Tuttle, James E.; Canavan, Edgar; DiPirro, Michael

    2009-01-01

    Many cryogenic systems use electrical cables containing phosphor bronze wire. While phosphor bronze's electrical and thermal conductivity values have been published, there is significant variation among different phosphor bronze formulations. The James Webb Space Telescope (JWST) will use several phosphor bronze wire harnesses containing a specific formulation (CDA 510, annealed temper). The heat conducted into the JWST instrument stage is dominated by these harnesses, and approximately half of the harness conductance is due to the phosphor bronze wires. Since the JWST radiators are expected to just keep the instruments at their operating temperature with limited cooling margin, it is important to know the thermal conductivity of the actual alloy being used. We describe an experiment which measured the electrical and thermal conductivity of this material between 4 and 295 Kelvin.

  13. Pretreatment of phosphoric acid of Annaba

    International Nuclear Information System (INIS)

    Kada, R.

    1990-03-01

    The most important step in the process of uranium recovery from phosphoric acid is the pretreatment operation. In this study, the adsorption of organic matters on activated carbon was carried out in a batch process and in a fixed bed column. First, the chemical and physical characterization of phosphoric acid, activated carbon and gypsum were performed. In addition, the organic matters were qualitatively analysed and a new and original quantitative method was experimented. Next, the various operating parameters such as agitation speed, granulometry, temperature, solid/liquid ratio, initial concentration, acid flowrate, and bed height were optimized. The experimental equilibrium isotherm was compared to the Langmuir, Freundlich, and Redlich-Peterson theoretical isotherms. It was noticed that the three models did not fit the experimental isotherm in the total concentration range. Thus, an original bilinear model was proposed. The influence of the operating conditions on the adsorption kinetics was also investigated. As a result of that, a new mathematical model was proposed to determine both the liquid and solid phases mass transfer and the solid phase diffusion coefficient. Finally, adsorption of organic matters on a fixed bed process allowed computation of the number of transfer units (NTU), the height of adsorption zone and the degree of saturation of activated carbon

  14. Tuning the diurnal natural daylight with phosphor converted white LED – Advent of new phosphor blend composition

    International Nuclear Information System (INIS)

    Kim, Yoon Hwa; Arunkumar, Paulraj; Park, Seung Hyok; Yoon, Ho Shin; Im, Won Bin

    2015-01-01

    Highlights: • Designed phosphor blend that mimics diurnal daylight for health benefits. • Developed new phosphor blend composition that mimics natural sunlight under near UV. • The phosphor blend also exhibits high CRI (≥90) under blue LED excitation. • Fabricated WLED exhibited ∼91% spectral resemblance with daylight at 4500 K. • While ∼39.2% spectral resemblance were observed for YAG:Ce 3+ at 4500 K. - Abstract: We demonstrate the feasibility of developing phosphor converted white LED (pc-WLED) that mimics diurnal natural daylight with the newly designed phosphor blend in the color temperature (CCT) 2700–6000 K for health benefits. Natural daylight (sunlight) spectrum possesses broad emission in the visible region and closely approximates black body radiator, with color rendition index (CRI) of 100 under wide CCT (2500–6500 K). Current white light LEDs although are efficient and durable, they are not broad enough compared to daylight. We report new phosphor blend based on Sr 3 MgSi 2 O 8 :Eu 2+ blue phosphor with broad emission and high CRI ≥ 96 under both near UV and blue excitation. The fabricated WLED has exhibited ∼91% spectral resemblance with natural daylight compared to 39.2% for YAG:Ce 3+ white LED at 4500 K. The developed phosphor blend tunes the spectrum in wider CCT and would be a prospective candidate for full spectrum daylight WLED

  15. Tuning the diurnal natural daylight with phosphor converted white LED – Advent of new phosphor blend composition

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Hwa [School of Materials Science and Engineering, Chonnam National University, 300, Yongbong-dong, Buk-gu, Gwangju 500-757 (Korea, Republic of); Research Institute, Force4 Corp., Daechon-dong, Buk-gu, Gwangju 500-470 (Korea, Republic of); Arunkumar, Paulraj [School of Materials Science and Engineering, Chonnam National University, 300, Yongbong-dong, Buk-gu, Gwangju 500-757 (Korea, Republic of); Park, Seung Hyok; Yoon, Ho Shin [Research Institute, Force4 Corp., Daechon-dong, Buk-gu, Gwangju 500-470 (Korea, Republic of); Im, Won Bin, E-mail: imwonbin@jnu.ac.kr [School of Materials Science and Engineering, Chonnam National University, 300, Yongbong-dong, Buk-gu, Gwangju 500-757 (Korea, Republic of)

    2015-03-15

    Highlights: • Designed phosphor blend that mimics diurnal daylight for health benefits. • Developed new phosphor blend composition that mimics natural sunlight under near UV. • The phosphor blend also exhibits high CRI (≥90) under blue LED excitation. • Fabricated WLED exhibited ∼91% spectral resemblance with daylight at 4500 K. • While ∼39.2% spectral resemblance were observed for YAG:Ce{sup 3+} at 4500 K. - Abstract: We demonstrate the feasibility of developing phosphor converted white LED (pc-WLED) that mimics diurnal natural daylight with the newly designed phosphor blend in the color temperature (CCT) 2700–6000 K for health benefits. Natural daylight (sunlight) spectrum possesses broad emission in the visible region and closely approximates black body radiator, with color rendition index (CRI) of 100 under wide CCT (2500–6500 K). Current white light LEDs although are efficient and durable, they are not broad enough compared to daylight. We report new phosphor blend based on Sr{sub 3}MgSi{sub 2}O{sub 8}:Eu{sup 2+} blue phosphor with broad emission and high CRI ≥ 96 under both near UV and blue excitation. The fabricated WLED has exhibited ∼91% spectral resemblance with natural daylight compared to 39.2% for YAG:Ce{sup 3+} white LED at 4500 K. The developed phosphor blend tunes the spectrum in wider CCT and would be a prospective candidate for full spectrum daylight WLED.

  16. Comparison of infrared-excited up-converting phosphors and europium nanoparticles as labels in a two-site immunoassay

    International Nuclear Information System (INIS)

    Ukonaho, Telle; Rantanen, Terhi; Jaemsen, Laura; Kuningas, Katri; Paekkilae, Henna; Loevgren, Timo; Soukka, Tero

    2007-01-01

    Research in the field of immunoassays and labels used in the detection has been recently focused on particulate reporters, which possess very high specific activity that excludes the label as a sensitivity limiting factor. However, the large size and shape of the particulate labels may produce additional problems to immunoassay performance. The aim of this work was to study with two identical non-competitive two-site immunoassays whether up-converting phosphor (UCP) particles are comparable in performance with europium(III) chelate-dyed nanoparticles as particulate labels. In addition we strived to verify the common assumption of the photostability of up-converting phosphor particles supporting their potential applicability in imaging. Detection limits in two-site immunoassay for free prostate-specific antigen (free-PSA) were 0.53 ng L -1 and 1.3 ng L -1 using two different up-converting phosphors and 0.16 ng L -1 using europium(III) nanoparticle. Large size distribution and non-specific binding of up-converting phosphor particles caused assay variation in low analyte concentrations and limited the analytical detection limit. The non-specific binding was the major factor limiting the analytical sensitivity of the immunoassay. The results suggests the need for nanoscaled and uniformely sized UCP-particles to increace the sensitivity and applicability of up-converting phosphor particles. Anti-Stokes photoluminescence of up-converting phosphor particles did not photobleach when measured repeatedly, on the contrary, the time-resolved fluorescence of europium nanoparticles photobleached relatively rapidly

  17. Liver fibrosis in type I Gaucher disease: magnetic resonance imaging, transient elastography and parameters of iron storage.

    Directory of Open Access Journals (Sweden)

    Anneloes E Bohte

    Full Text Available Long term liver-related complications of type-1 Gaucher disease (GD, a lysosomal storage disorder, include fibrosis and an increased incidence of hepatocellular carcinoma. Splenectomy has been implicated as a risk factor for the development of liver pathology in GD. High ferritin concentrations are a feature of GD and iron storage in Gaucher cells has been described, but iron storage in the liver in relation to liver fibrosis has not been studied. Alternatively, iron storage in GD may be the result of iron supplementation therapy or regular blood transfusions in patients with severe cytopenia. In this pilot study, comprising 14 type-1 GD patients (7 splenectomized, 7 non-splenectomized and 7 healthy controls, we demonstrate that liver stiffness values, measured by Transient Elastography and MR-Elastography, are significantly higher in splenectomized GD patients when compared with non-splenectomized GD patients (p = 0.03 and p = 0.01, respectively. Liver iron concentration was elevated (>60±30 µmol/g in 4 GD patients of whom 3 were splenectomized. No relationship was found between liver stiffness and liver iron concentration. HFE gene mutations were more frequent in splenectomized (6/7 than in non-splenectomized (2/7 participants (p = 0.10. Liver disease appeared more advanced in splenectomized than in non-splenectomized patients. We hypothesize a relationship with excessive hepatic iron accumulation in splenectomized patients. We recommend that all splenectomized patients, especially those with evidence of substantial liver fibrosis undergo regular screening for HCC, according to current guidelines.

  18. High Efficiency Colloidal Quantum Dot Phosphors

    Energy Technology Data Exchange (ETDEWEB)

    Kahen, Keith

    2013-12-31

    The project showed that non-Cd containing, InP-based nanocrystals (semiconductor materials with dimensions of ~6 nm) have high potential for enabling next-generation, nanocrystal-based, on chip phosphors for solid state lighting. Typical nanocrystals fall short of the requirements for on chip phosphors due to their loss of quantum efficiency under the operating conditions of LEDs, such as, high temperature (up to 150 °C) and high optical flux (up to 200 W/cm2). The InP-based nanocrystals invented during this project maintain high quantum efficiency (>80%) in polymer-based films under these operating conditions for emission wavelengths ranging from ~530 to 620 nm. These nanocrystals also show other desirable attributes, such as, lack of blinking (a common problem with nanocrystals which limits their performance) and no increase in the emission spectral width from room to 150 °C (emitters with narrower spectral widths enable higher efficiency LEDs). Prior to these nanocrystals, no nanocrystal system (regardless of nanocrystal type) showed this collection of properties; in fact, other nanocrystal systems are typically limited to showing only one desirable trait (such as high temperature stability) but being deficient in other properties (such as high flux stability). The project showed that one can reproducibly obtain these properties by generating a novel compositional structure inside of the nanomaterials; in addition, the project formulated an initial theoretical framework linking the compositional structure to the list of high performance optical properties. Over the course of the project, the synthetic methodology for producing the novel composition was evolved to enable the synthesis of these nanomaterials at a cost approximately equal to that required for forming typical conventional nanocrystals. Given the above results, the last major remaining step prior to scale up of the nanomaterials is to limit the oxidation of these materials during the tens of

  19. The quality study of recycled glass phosphor waste for LED

    Science.gov (United States)

    Tsai, Chun-Chin; Chen, Guan-Hao; Yue, Cheng-Feng; Chen, Cin-Fu; Cheng, Wood-Hi

    2017-02-01

    To study the feasibility and quality of recycled glass phosphor waste for LED packaging, the experiments were conducted to compare optical characteristics between fresh color conversion layer and that made of recycled waste. The fresh color conversion layer was fabricated through sintering pristine mixture of Y.A.G. powder [yellow phosphor (Y3AlO12 : Ce3+). Those recycled waste glass phosphor re-melted to form Secondary Molten Glass Phosphor (S.M.G.P.). The experiments on such low melting temperature glass results showed that transmission rates of S.M.G.P. are 9% higher than those of first-sintered glass phosphor, corresponding to 1.25% greater average bubble size and 36% more bubble coverage area in S.M.G.P. In the recent years, high power LED modules and laser projectors have been requiring higher thermal stability by using glass phosphor materials for light mixing. Nevertheless, phosphor and related materials are too expensive to expand their markets. It seems a right trend and research goal that recycling such waste of high thermal stability and quality materials could be preferably one of feasible cost-down solutions. This technical approach could bring out brighter future for solid lighting and light source module industries.

  20. Compact fluorescent lamp phosphors in accidental radiation monitoring

    International Nuclear Information System (INIS)

    Murthy, K. V. R.; Pallavi, S. P.; Ghildiyal, R.; Parmar, M. C.; Patel, Y. S.; Ravi Kumar, V.; Sai Prasad, A. S.; Natarajan, V.; Page, A. G.

    2006-01-01

    The application of lamp phosphors for accidental dosimetry is a new concept. Since the materials used in fluorescent lamps are good photo luminescent materials, if one can either use the inherent defects present in the phosphor or add suitable modifiers to induce thermoluminescence (TL) in these phosphors, then the device (fluorescent lamp) can be used as an accidental dosemeter. In continuation of our search for a suitable phosphor material, which can serve both as an efficient lamp phosphor and as a good radiation monitoring device, detailed examination has been carried out on cerium and terbium-doped lanthanum phosphate material. A 90 Sr beta source with 50 mCi strength (1.85 GBq) was used as the irradiation source for TL studies. The TL response as a function of dose received was examined for all phosphors used and it was observed that the intensity of the TL peak vs. dose received was a linear function in the dose range 0.1-200 Gy in each case. Incidentally LaPO 4 :Ce,Tb is a component of the compact fluorescent lamp marketed recently as an energy bright light source. Besides having very good luminescence efficiency, good dosimetric properties of these phosphors render them useful for their use in accidental dosimetry also. (authors)

  1. Recent advances in enhanced luminescence upconversion of lanthanide-doped NaYF4 phosphors

    Science.gov (United States)

    Kumar, Deepak; Verma, Kartikey; Verma, Shefali; Chaudhary, Babulal; Som, Sudipta; Sharma, Vishal; Kumar, Vijay; Swart, Hendrik C.

    2018-04-01

    NaYF4 is regarded as the best upconversion (UC) matrix owing to its low phonon energy, more chemical stability, and a superior refractive index. This review reports on the various synthesis techniques of lanthanide-doped NaYF4 phosphors for UC application. The UC intensity depends on different properties of the matrix and those are discussed in detail. Plasmon-enhanced luminescence UC of the lanthanide-doped NaYF4 core-shells structure is discussed based on a literature survey. The present review provides the information about how the UC intensity can be enhanced. The idea about the UC is then deliberately used for versatile applications such as luminescent materials, display devices, biomedical imaging and different security appliances. In addition, the present review demonstrates the recent trends of NaYF4 UC materials in solar cell devices. The role of NaYF4 phosphor to eradicate the spectral variance among the incident solar spectrum, semiconductor as well as the sub-band gap nature of the semiconductor materials is also discussed in detail. Considering the fact that the research status on NaYF4 phosphor for photovoltaic application is now growing, the present review is therefore very important to the researchers. More importantly, this may promote more interesting research platforms to investigate the realistic use of UC nanophosphors as spectral converters for solar cells.

  2. Tritium storage

    International Nuclear Information System (INIS)

    Hircq, B.

    1990-01-01

    This document represents a synthesis relative to tritium storage. After indicating the main storage particularities as regards tritium, storages under gaseous and solid form are after examined before establishing choices as a function of the main criteria. Finally, tritium storage is discussed regarding tritium devices associated to Fusion Reactors and regarding smaller devices [fr

  3. The Monte Carlo evaluation of noise and resolution properties of granular phosphor screens

    International Nuclear Information System (INIS)

    Liaparinos, P F; Kandarakis, I S

    2009-01-01

    The imaging performance of phosphor screens, used as x-ray detectors in diagnostic medical imaging systems, is affected by their both noise and resolution properties. Amplification and blurring processes are due to a sequence of conversion stages within the screen which contribute to fluctuations in the number and spatial distribution of the optical quanta recorded by the optical detector (e.g. film, television camera, CCD, etc). The purpose of this paper is to investigate the stochastic noise arising from granularity as well as the variation of spatial resolution of granular fluorescent screens in terms of the detector's structure. Using a custom-validated Monte Carlo model, the parameters of interest were evaluated for the widely used Gd 2 O 2 S:Tb phosphor material. We have studied the variations of (i) the modulation transfer function, (ii) the Swank factor and (iii) the zero-frequency detective quantum efficiency (DQE), under several conditions employed in conventional and digital mammography and radiology. Several evaluations are provided for the imaging metrics as a function of the x-ray energy (18 keV, 49 keV and 51 keV), phosphor coating weight (20 mg cm -2 , 34 mg cm -2 and 60 mg cm -2 ), grain size (from 4 μm up to 13 μm) and packing density (from 50% up to 85%). It was found that screens of high packing density can combine high zero-frequency DQE with improved resolution properties. For a digital mammographic imaging system (34 mg cm -2 , 18 keV), a packing density of 85% can improve the spatial resolution of the screen by 1.6 cycles mm -1 in comparison to that of 50% packing density. Similarly, for radiographic cases (60 mg cm -2 , 49 keV), the spatial resolution can be improved by 1.7 cycles mm -1 . The aforementioned findings provide the resolution benefits of using high packing density screens.

  4. SU-E-T-610: Phosphor-Based Fiber Optic Probes for Proton Beam Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Darafsheh, A; Soldner, A; Liu, H; Kassaee, A; Zhu, T; Finlay, J [Univ Pennsylvania, Philadelphia, PA (United States)

    2015-06-15

    Purpose: To investigate feasibility of using fiber optics probes with rare-earth-based phosphor tips for proton beam radiation dosimetry. We designed and fabricated a fiber probe with submillimeter resolution (<0.5 mm3) based on TbF3 phosphors and evaluated its performance for measurement of proton beam including profiles and range. Methods: The fiber optic probe with TbF3 phosphor tip, embedded in tissue-mimicking phantoms was irradiated with double scattering proton beam with energy of 180 MeV. Luminescence spectroscopy was performed by a CCD-coupled spectrograph to analyze the emission spectra of the fiber tip. In order to measure the spatial beam profile and percentage depth dose, we used singular value decomposition method to spectrally separate the phosphors ionoluminescence signal from the background Cerenkov radiation signal. Results: The spectra of the TbF3 fiber probe showed characteristic ionoluminescence emission peaks at 489, 542, 586, and 620 nm. By using singular value decomposition we found the contribution of the ionoluminescence signal to measure the percentage depth dose in phantoms and compared that with measurements performed with ion chamber. We observed quenching effect at the spread out Bragg peak region, manifested as under-responding of the signal, due to the high LET of the beam. However, the beam profiles were not dramatically affected by the quenching effect. Conclusion: We have evaluated the performance of a fiber optic probe with submillimeter resolution for proton beam dosimetry. We demonstrated feasibility of spectral separation of the Cerenkov radiation from the collected signal. Such fiber probes can be used for measurements of proton beams profile and range. The experimental apparatus and spectroscopy method developed in this work provide a robust platform for characterization of proton-irradiated nanophosphor particles for ultralow fluence photodynamic therapy or molecular imaging applications.

  5. Development of BaSO4:Eu thermoluminescence phosphor

    International Nuclear Information System (INIS)

    Madhusoodanan, U.; Jose, M.T.; Lakshmanan, A.R.

    1999-01-01

    A highly sensitive thermoluminescence (TL) phosphor based on BaSO 4 :Eu was developed following the coprecipitation technique and firing in argon atmosphere at 1123 K. Photoluminescence studies confirm that firing in argon atmosphere instead of air increased the incorporation of Eu ions in 2+ valence state. At low γ-ray doses, its TL sensitivity is nearly 2 to 3 times higher than that of CaSO 4 :Dy phosphor. The other salient features of this BaSO 4 :Eu TL phosphor are a constant glow curve shape and a nearly linear γ-ray dose response

  6. Development of BaSO sub 4 :Eu thermoluminescence phosphor

    CERN Document Server

    Madhusoodanan, U; Lakshmanan, A R

    1999-01-01

    A highly sensitive thermoluminescence (TL) phosphor based on BaSO sub 4 :Eu was developed following the coprecipitation technique and firing in argon atmosphere at 1123 K. Photoluminescence studies confirm that firing in argon atmosphere instead of air increased the incorporation of Eu ions in 2+ valence state. At low gamma-ray doses, its TL sensitivity is nearly 2 to 3 times higher than that of CaSO sub 4 :Dy phosphor. The other salient features of this BaSO sub 4 :Eu TL phosphor are a constant glow curve shape and a nearly linear gamma-ray dose response.

  7. Comparison between mixed and spatially separated remote phosphor fabricated via a screen-printing process

    Science.gov (United States)

    Kim, Byung-Ho; Hwang, Jonghee; Lee, Young Jin; Kim, Jin-Ho; Jeon, Dae-Woo; Lee, Mi Jai

    2016-08-01

    We developed a fabrication method for remote phosphor by a screen-printing process, using green phosphor, red phosphor, and thermally stable glass frit. The glass frit was introduced for long-term stability. The optical properties of the remote phosphor were observed via an integrating sphere; the photoluminescence spectrum dramatically changed on incorporating a minor amount of the red phosphor. These unique optical properties were elucidated using four factors: phosphor ratio, scattering induced by packing density, light intensity per unit volume, and reabsorption. The thermal stability of the remote phosphor was investigated at 500°C, demonstrating its outstanding thermal properties.

  8. Image quality in digital radiographic systems

    Directory of Open Access Journals (Sweden)

    Almeida Solange Maria de

    2003-01-01

    Full Text Available The aim of the present study was to evaluate the image quality of four direct digital radiographic systems. Radiographs were made of the maxillary central incisor and mandibular left molar regions of a dry skull, and an aluminum step-wedge. The X-ray generator operated at 10 mA, 60 and 70 kVp, and images were acquired with 3, 5, 8, 12, 24 and 48 exposure pulses. Six well-trained observers classified the images by means of scores from 1 to 3. Collected data were submitted to nonparametric statistical analysis using Fisher's exact test. Statistical analysis showed significant differences (p<0.01 in image quality with the four systems. Based on the results, it was possible to conclude that: 1 all of the digital systems presented good performance in producing acceptable images for diagnosis, if the exposures of the step-wedge and the maxillary central incisor region were made at 5 pulses, as well as at 8 pulses for the mandibular left molar region, selecting 60 or 70kVp; 2 higher percentages of acceptable images were obtained with the administration of lower radiation doses in CCD-sensors (charge-coupled device; 3 the Storage Phosphor systems produced acceptable images at a large range of exposure settings, that included low, intermediate and high radiation doses.

  9. [RS estimation of inventory parameters and carbon storage of moso bamboo forest based on synergistic use of object-based image analysis and decision tree].

    Science.gov (United States)

    Du, Hua Qiang; Sun, Xiao Yan; Han, Ning; Mao, Fang Jie

    2017-10-01

    By synergistically using the object-based image analysis (OBIA) and the classification and regression tree (CART) methods, the distribution information, the indexes (including diameter at breast, tree height, and crown closure), and the aboveground carbon storage (AGC) of moso bamboo forest in Shanchuan Town, Anji County, Zhejiang Province were investigated. The results showed that the moso bamboo forest could be accurately delineated by integrating the multi-scale ima ge segmentation in OBIA technique and CART, which connected the image objects at various scales, with a pretty good producer's accuracy of 89.1%. The investigation of indexes estimated by regression tree model that was constructed based on the features extracted from the image objects reached normal or better accuracy, in which the crown closure model archived the best estimating accuracy of 67.9%. The estimating accuracy of diameter at breast and tree height was relatively low, which was consistent with conclusion that estimating diameter at breast and tree height using optical remote sensing could not achieve satisfactory results. Estimation of AGC reached relatively high accuracy, and accuracy of the region of high value achieved above 80%.

  10. Analysis of phosphoric ore bacterial and eucaryal microbial diversity ...

    African Journals Online (AJOL)

    SAM

    Received 30 July, 2013; Accepted 4 July, 2014. The aim ... using the single strand conformation polymorphism (SSCP) technique and ... Phosphoric industry generates a considerable quantity of ..... This phenomenon could well be the case for.

  11. The preparation of 32P labelled phosphorous acid

    International Nuclear Information System (INIS)

    Henderson, D.; Jenkinson, A.; Sorby, P.

    1986-11-01

    Phosphorous acid labelled with 32 P has been prepared, on a small scale, starting from neutron-irradiated phosphorus. The compound is intended for tracer studies in the development of novel fungicides

  12. Oxycarbonitride phosphors and light emitting devices using the same

    Science.gov (United States)

    Li, Yuanqiang; Romanelli, Michael Dennis; Tian, Yongchi

    2013-10-08

    Disclosed herein is a novel family of oxycarbidonitride phosphor compositions and light emitting devices incorporating the same. Within the sextant system of M--Al--Si--O--N--C--Ln and quintuplet system of M--Si--O--N--C--Ln (M=alkaline earth element, Ln=rare earth element), the phosphors are composed of either one single crystalline phase or two crystalline phases with high chemical and thermal stability. In certain embodiments, the disclosed phosphor of silicon oxycarbidonitrides emits green light at wavelength between 530-550 nm. In further embodiments, the disclosed phosphor compositions emit blue-green to yellow light in a wavelength range of 450-650 nm under near-UV and blue light excitation.

  13. Quantitative Characterization of Phosphor Detector for Fusion Plasmas

    International Nuclear Information System (INIS)

    Baciero, A.; Zurro, B.; McCarthy, K. J.

    2004-01-01

    Experiments made to characterize phosphor screens with application as broadband radiation detectors, are described. Several radiation sources, covering the spectral range between the ultraviolet and X ray, were used. In addition, details are given of three original phosphor-screen-based detectors that were designed for use as broadband detectors in magnetically confined fusion devices. The first measurements obtained with these detectors in plasmas created in the TJ-II stellarator device are presented together with the analysis performed. (Author)

  14. Phosphors containing boron and metals of Group IIIA and IIIB

    Science.gov (United States)

    Setlur, Anant Achyut; Srivastava, Alok Mani; Comanzo, Holly Ann; Manivannan, Venkatesan

    2006-10-31

    A phosphor comprises: (a) at least a first metal selected from the group consisting of yttrium and elements of lanthanide series other than europium; (b) at least a second metal selected from the group consisting of aluminum, gallium, indium, and scandium; (c) boron; and (d) europium. The phosphor is used in light source that comprises a UV radiation source to convert UV radiation to visible light.

  15. Activated phosphors having matrices of yttrium-transition metal compound

    International Nuclear Information System (INIS)

    De Kalb, E.L.; Fassel, V.A.

    1975-01-01

    A method is described for preparing a phosphor composition containing a lanthanide activator element with a host matrix having a transition element as a major component. The host matrix is composed of certain rare earth phosphates or vanadates such as YPO 4 with a portion of the rare earth replaced with one or more of the transition elements. On x-ray or other electromagnetic excitation, trace lanthanide impurities or additives within the phosphor are spectrometrically determined from their characteristic luminescence

  16. X-ray imaging using digital cameras

    Science.gov (United States)

    Winch, Nicola M.; Edgar, Andrew

    2012-03-01

    The possibility of using the combination of a computed radiography (storage phosphor) cassette and a semiprofessional grade digital camera for medical or dental radiography is investigated. We compare the performance of (i) a Canon 5D Mk II single lens reflex camera with f1.4 lens and full-frame CMOS array sensor and (ii) a cooled CCD-based camera with a 1/3 frame sensor and the same lens system. Both systems are tested with 240 x 180 mm cassettes which are based on either powdered europium-doped barium fluoride bromide or needle structure europium-doped cesium bromide. The modulation transfer function for both systems has been determined and falls to a value of 0.2 at around 2 lp/mm, and is limited by light scattering of the emitted light from the storage phosphor rather than the optics or sensor pixelation. The modulation transfer function for the CsBr:Eu2+ plate is bimodal, with a high frequency wing which is attributed to the light-guiding behaviour of the needle structure. The detective quantum efficiency has been determined using a radioisotope source and is comparatively low at 0.017 for the CMOS camera and 0.006 for the CCD camera, attributed to the poor light harvesting by the lens. The primary advantages of the method are portability, robustness, digital imaging and low cost; the limitations are the low detective quantum efficiency and hence signal-to-noise ratio for medical doses, and restricted range of plate sizes. Representative images taken with medical doses are shown and illustrate the potential use for portable basic radiography.

  17. High temperature thermometric phosphors for use in a temperature sensor

    Science.gov (United States)

    Allison, Stephen W.; Cates, Michael R.; Boatner, Lynn A.; Gillies, George T.

    1998-01-01

    A high temperature phosphor consists essentially of a material having the general formula LuPO.sub.4 :Dy.sub.(x),Eu.sub.(y), wherein: 0.1 wt %.ltoreq.x.ltoreq.20 wt % and 0.1 wt %.ltoreq.y.ltoreq.20 wt %. The high temperature phosphor is in contact with an article whose temperature is to be determined. The article having the phosphor in contact with it is placed in the environment for which the temperature of the article is to be determined. The phosphor is excited by a laser causing the phosphor to fluoresce. The emission from the phosphor is optically focused into a beam-splitting mirror which separates the emission into two separate emissions, the emission caused by the dysprosium dopant and the emission caused by the europium dopent. The separated emissions are optically filtered and the intensities of the emission are detected and measured. The ratio of the intensity of each emission is determined and the temperature of the article is calculated from the ratio of the intensities of the separate emissions.

  18. Light Converting Inorganic Phosphors for White Light-Emitting Diodes

    Directory of Open Access Journals (Sweden)

    Chiao-Wen Yeh

    2010-03-01

    Full Text Available White light-emitting diodes (WLEDs have matched the emission efficiency of florescent lights and will rapidly spread as light source for homes and offices in the next 5 to 10 years. WLEDs provide a light element having a semiconductor light emitting layer (blue or near-ultraviolet (nUV LEDs and photoluminescence phosphors. These solid-state LED lamps, rather than organic light emitting diode (OLED or polymer light-emitting diode (PLED, have a number of advantages over conventional incandescent bulbs and halogen lamps, such as high efficiency to convert electrical energy into light, reliability and long operating lifetime. To meet with the further requirement of high color rendering index, warm light with low color temperature, high thermal stability and higher energy efficiency for WLEDs, new phosphors that can absorb excitation energy from blue or nUV LEDs and generate visible emissions efficiently are desired. The criteria of choosing the best phosphors, for blue (450-480 nm and nUV (380-400 nm LEDs, strongly depends on the absorption and emission of the phosphors. Moreover, the balance of light between the emission from blue-nUV LEDs and the emissions from phosphors (such as yellow from Y3Al5O12:Ce3+ is important to obtain white light with proper color rendering index and color temperature. Here, we will review the status of phosphors for LEDs and prospect the future development.

  19. Light Converting Inorganic Phosphors for White Light-Emitting Diodes

    Science.gov (United States)

    Chen, Lei; Lin, Chun-Che; Yeh, Chiao-Wen; Liu, Ru-Shi

    2010-01-01

    White light-emitting diodes (WLEDs) have matched the emission efficiency of florescent lights and will rapidly spread as light source for homes and offices in the next 5 to 10 years. WLEDs provide a light element having a semiconductor light emitting layer (blue or near-ultraviolet (nUV) LEDs) and photoluminescence phosphors. These solid-state LED lamps, rather than organic light emitting diode (OLED) or polymer light-emitting diode (PLED), have a number of advantages over conventional incandescent bulbs and halogen lamps, such as high efficiency to convert electrical energy into light, reliability and long operating lifetime. To meet with the further requirement of high color rendering index, warm light with low color temperature, high thermal stability and higher energy efficiency for WLEDs, new phosphors that can absorb excitation energy from blue or nUV LEDs and generate visible emissions efficiently are desired. The criteria of choosing the best phosphors, for blue (450−480 nm) and nUV (380−400 nm) LEDs, strongly depends on the absorption and emission of the phosphors. Moreover, the balance of light between the emission from blue-nUV LEDs and the emissions from phosphors (such as yellow from Y3Al5O12:Ce3+) is important to obtain white light with proper color rendering index and color temperature. Here, we will review the status of phosphors for LEDs and prospect the future development.

  20. Angle-resolved photoluminescence spectrum of a uniform phosphor layer

    Science.gov (United States)

    Fujieda, Ichiro; Ohta, Masamichi

    2017-10-01

    A photoluminescence spectrum depends on an emission angle due to self-absorption in a phosphor material. Assuming isotropic initial emission and Lambert-Beer's law, we have derived simple expressions for the angle-resolved spectra emerging from the top and bottom surfaces of a uniform phosphor layer. The transmittance of an excitation light through the phosphor layer can be regarded as a design parameter. For a strongly-absorbing phosphor layer, the forward flux is less intense and more red-shifted than the backward flux. The red-shift is enhanced as the emission direction deviates away from the plane normal. When we increase the transmittance, the backward flux decreases monotonically. The forward flux peaks at a certain transmittance value. The two fluxes become similar to each other for a weakly-absorbing phosphor layer. We have observed these behaviors in experiment. In a practical application, self-absorption decreases the efficiency of conversion and results in angle-dependent variations in chromaticity coordinates. A patterned phosphor layer with a secondary optical element such as a remote reflector alleviates these problems.

  1. Rare-earth doped phosphors: oldies or goldies?

    International Nuclear Information System (INIS)

    Moine, B.; Bizarri, G.

    2003-01-01

    The scientific research on phosphors has a long history starting more than 100 years ago. But recently the appearance of new kinds of displays and lighting devices (plasma display, fluorescent lamp without mercury, etc.) induced an increase of the research of new phosphors with better luminous efficiency than those available up to now. It has been shown that the behavior of 'classical' phosphors in a plasma display panel is quite different than in a cathode ray tube and that the vacuum ultraviolet (VUV) excitation process has to be studied with care in order to improve the phosphors efficiency. That is particularly true in PDPs. It is well established now that a good phosphor for electronic or ultraviolet excitation is not necessarily a good choice for excitation in VUV. This is probably due to the fact that the excitation process is very different in that case and also because the penetration depth of the VUV photons is extremely small inducing a large contribution of the surface of the phosphor. We will illustrate this with some examples. Methods to accelerate luminous intensity decrease under VUV excitation will be described. Low efficiency, fast aging process are both drawbacks that can be solved only in the framework of fundamental studies. Quantum cutting emission may be a solution for the first one but no satisfactory process was proposed for the moment to solve the second

  2. Electronic Document Imaging and Optical Storage Systems for Local Governments: An Introduction. Local Government Records Technical Information Series. Number 21.

    Science.gov (United States)

    Schwartz, Stanley F.

    This publication introduces electronic document imaging systems and provides guidance for local governments in New York in deciding whether such systems should be adopted for their own records and information management purposes. It advises local governments on how to develop plans for using such technology by discussing its advantages and…

  3. Technique of proton and phosphorous MR spectroscopy; Technik der Protonen- und Phosphor-MR-Spektroskopie

    Energy Technology Data Exchange (ETDEWEB)

    Backens, M. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany)

    2017-06-15

    Magnetic resonance spectroscopy (MRS) is an important non-invasive method that can reveal the concentration and spatial distribution of particular biochemically relevant tissue metabolites. Proton MRS is routinely applicable in the clinical setting providing good quality results even with a moderate magnetic field strength of 1.5 T. Relative values of metabolite concentrations are mostly used for the assessment of metabolic disorders. Absolute quantification of metabolites can be achieved by means of internal or external reference scans. Phosphorous MRS extends the range of detectable molecules to energy and cell membrane metabolism. The lower detection limit of metabolite concentrations is in the range of some mmol/kg. Depending on the magnetic field strength, MRS enables a spatial resolution of a few milliliters. The use of phosphorous MRS is considerably limited because higher field strengths of at least 3.0 T and additional expensive hardware for signal processing are required. (orig.) [German] Die MR-Spektroskopie (MRS) ist eine wichtige nichtinvasive Untersuchungsmethode, die Konzentration und raeumliche Verteilung einiger biochemisch relevanter Metaboliten im Gewebe ermitteln kann. Die Protonenspektroskopie ist klinisch etabliert, in der Routine einfach durchfuehrbar und liefert bereits bei einer Magnetfeldstaerke von 1,5 T qualitativ gute Ergebnisse. Fuer die Beurteilung von Stoffwechselveraenderungen werden Metabolitenkonzentrationen meist als Relativwerte angegeben. Mithilfe interner oder externer Referenzmessungen sind auch absolute Metabolitenkonzentrationen berechenbar. Die Phosphorspektroskopie erweitert den Bereich der detektierbaren Molekuele auf den Energie- und Zellmembranstoffwechsel. Die minimale nachweisbare Metabolitenkonzentration liegt bei einigen mmol/kg. Abhaengig von der Magnetfeldstaerke ist eine raeumliche Aufloesung der MRS von wenigen Millilitern erreichbar. Der Einsatz der Phosphor-MRS wird dadurch erheblich eingeschraenkt, dass sie

  4. Energy storage

    Science.gov (United States)

    Kaier, U.

    1981-04-01

    Developments in the area of energy storage are characterized, with respect to theory and laboratory, by an emergence of novel concepts and technologies for storing electric energy and heat. However, there are no new commercial devices on the market. New storage batteries as basis for a wider introduction of electric cars, and latent heat storage devices, as an aid for solar technology applications, with satisfactory performance standards are not yet commercially available. Devices for the intermediate storage of electric energy for solar electric-energy systems, and for satisfying peak-load current demands in the case of public utility companies are considered. In spite of many promising novel developments, there is yet no practical alternative to the lead-acid storage battery. Attention is given to central heat storage for systems transporting heat energy, small-scale heat storage installations, and large-scale technical energy-storage systems.

  5. Blue and green emissions with high color purity from nanocrystalline Ca2Gd8Si6O26:Ln (Ln = Tm or Er) phosphors

    International Nuclear Information System (INIS)

    Seeta Rama Raju, G.; Park, Jin Young; Jung, Hong Chae; Pavitra, E.; Moon, Byung Kee; Jeong, Jung Hyun; Yu, Jae Su; Kim, Jung Hwan; Choi, Haeyoung

    2011-01-01

    phosphors for lighting or imaging devices.

  6. Preparation of high purification and food grade phosphoric acid from technical grade phosphoric acid by liquid-liquid detraction method

    International Nuclear Information System (INIS)

    Alimoradi, M.; Borji, F.; Kishani, A.

    2002-01-01

    Pay attention to increasing consumption of high purification and food grade phosphoric acid in various industries and food industries and on in on hand and lack of preparation between production and distribution of this products its purification is so vital. In this article of liquid-liquid extraction method with normal hexane-mixture of ammonia and acetone-diisopropyl alcohol and normal butanol solvents and these determination of distribution coefficient each one with ph-me try titration we can evaluate effectiveness and sufficiency each one. Because of proper coefficient distribution and its local production of normal butanol solvent and low price is the best solvent. To phosphoric acid modifying coefficient distribution for extraction of phosphoric acid we can add a little value sulfuric acid to the mixture and to remove flouride impurity we add a little Na 2 O. After extraction stage extracted phosphoric acid in the normal strips by evaluating with distilled water and then by passing the carbon active bed and following passes of cationic resine column and concentrated with vacuum distillation. Conclusion of this article is produce of phosphoric acid 85% w/w and food grade from impure phosphoric acid 52% w/w with technical grade

  7. Study of phosphors determination in biological samples

    International Nuclear Information System (INIS)

    Oliveira, Rosangela Magda de.

    1994-01-01

    In this paper, phosphors determination by neutron activation analysis in milk and bone samples was studied employing both instrumental and radiochemical separation methods. The analysis with radiochemistry separation consisted of the simultaneous irradiation of the samples and standards during 30 minutes, dissolution of the samples, hold back carrier, addition precipitation of phosphorus with ammonium phosphomolibdate (A.M.P.) and phosphorus-32 by counting by using Geiger-Mueller detector. The instrumental analysis consisted of the simultaneous irradiation of the samples and standards during 30 minutes, transfer of the samples into a counting planchet and measurement of the beta radiation emitted by phosphorus-32, after a suitable decay period. After the phosphorus analysis methods were established they were applied to both commercial milk and animal bone samples, and data obtained in the instrumental and radiochemical separation methods for each sample, were compared between themselves. In this work, it became possible to obtain analysis methods for phosphorus that can be applied independently of the sample quantity available, and the phosphorus content in the samples or interference that can be present in them. (author). 51 refs., 7 figs., 4 tabs

  8. Phosphoric acid fuel cell platinum use study

    Science.gov (United States)

    Lundblad, H. L.

    1983-05-01

    The U.S. Department of Energy is promoting the private development of phosphoric acid fuel cell (PAFC) power plants for terrestrial applications. Current PAFC technology utilizes platinum as catalysts in the power electrodes. The possible repercussions that the platinum demand of PAFC power plant commercialization will have on the worldwide supply and price of platinum from the outset of commercialization to the year 2000 are investigated. The platinum demand of PAFC commercialization is estimated by developing forecasts of platinum use per unit of generating capacity and penetration of PAFC power plants into the electric generation market. The ability of the platinum supply market to meet future demands is gauged by assessing the size of platinum reserves and the capability of platinum producers to extract, refine and market sufficient quantities of these reserves. The size and timing of platinum price shifts induced by the added demand of PAFC commercialization are investigated by several analytical methods. Estimates of these price shifts are then used to calculate the subsequent effects on PAFC power plant capital costs.

  9. Thermoluminescence of NaF:Eu{sup 3+} phosphors exposed to beta particle irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Haro, A.R.; Cruz-Vazquez, C.; Orante-Barron, V.R. [Polymers and Materials Research Department, University of Sonora (Mexico); Bernal, R. [Physics Research Department, University of Sonora (Mexico); Kitis, G. [Nuclear Physics Laboratory, Aristotle University of Thessaloniki (Greece); Castano, V.M. [Applied Physics and Advanced Technology Center, Physics Institute, Autonomous National University of Mexico (Mexico)

    2013-02-15

    Pellet-shaped NaF:Eu{sup 3+} phosphors were synthesized by sintering. When a 5 K/s heating rate was used, the char-acteristic glow curves of beta particle irradiated samples exhibited two thermoluminescence (TL) maxima located at 401 K and 498 K, being the higher temperature max-imum the most intense. A peak located between 473 and 523 K is considered to have a position very suitable to assure good thermal stability of the stored TL, so this phosphor is attractive for radiation dosimetry. Beta particle irradiated samples displayed a TL response that increases as the radiation dose increased in the 0.08 to 42.5 Gy dose range, with a linear behavior below 10 Gy followed by a sublinear one for higher doses. Under storage after irradiation, the TL maximum at 498 K displayed a remarkable stability, and the TL fading revealed that the maximum at 401 K is not a single peak. (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. (Zn, Mg)2GeO4:Mn2+ submicrorods as promising green phosphors for field emission displays: hydrothermal synthesis and luminescence properties.

    Science.gov (United States)

    Shang, Mengmeng; Li, Guogang; Yang, Dongmei; Kang, Xiaojiao; Peng, Chong; Cheng, Ziyong; Lin, Jun

    2011-10-07

    (Zn(1-x-y)Mg(y))(2)GeO(4): xMn(2+) (y = 0-0.30; x = 0-0.035) phosphors with uniform submicrorod morphology were synthesized through a facile hydrothermal process. X-Ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), photoluminescence (PL), and cathodoluminescence (CL) spectroscopy were utilized to characterize the samples. SEM and TEM images indicate that Zn(2)GeO(4):Mn(2+) samples consist of submicrorods with lengths around 1-2 μm and diameters around 200-250 nm, respectively. The possible formation mechanism for Zn(2)GeO(4) submicrorods has been presented. PL and CL spectroscopic characterizations show that pure Zn(2)GeO(4) sample shows a blue emission due to defects, while Zn(2)GeO(4):Mn(2+) phosphors exhibit a green emission corresponding to the characteristic transition of Mn(2+) ((4)T(1)→(6)A(1)) under the excitation of UV and low-voltage electron beam. Compared with Zn(2)GeO(4):Mn(2+) sample prepared by solid-state reaction, Zn(2)GeO(4):Mn(2+) phosphors obtained by hydrothermal process followed by high temperature annealing show better luminescence properties. In addition, codoping Mg(2+) ions into the lattice to substitute for Zn(2+) ions can enhance both the PL and CL intensity of Zn(2)GeO(4):Mn(2+) phosphors. Furthermore, Zn(2)GeO(4):Mn(2+) phosphors exhibit more saturated green emission than the commercial FEDs phosphor ZnO:Zn, and it is expected that these phosphors are promising for application in field-emission displays.

  11. Luminescent characteristics of UV excited Sr_0_._5Ca_0_._5TiO_3: Pr"3"+ reddish-orange phosphor

    International Nuclear Information System (INIS)

    Vidyadharan, Viji; Mohan P, Remya; Joseph, Cyriac; Unnikrishnan, N.V.; Biju, P.R.

    2016-01-01

    Pr"3"+ doped Sr_0_._5Ca_0_._5TiO_3 phosphors were synthesised by solid state reaction process. The structure, surface morphology and photoluminescence of the prepared phosphors were analysed using XRD, SEM and photoluminescence spectroscopy respectively. The XRD pattern confirmed orthorhombic perovskite structure of the Sr_0_._5Ca_0_._5TiO_3: x Pr"3"+ phosphor. Agglomeration of particles with irregular shapes is observed from the SEM images. The emission spectra of Sr_0_._5Ca_0_._5TiO_3: x Pr"3"+ phosphor shows the samples can be effectively excited with UV light at 336 nm and exhibit a strong reddish-orange emission at 611 nm. Concentration dependence of emission intensity shows concentration quenching effect on increasing Pr"3"+ concentration after x = 0.1 because of dipole–dipole interaction. Using Blasse's formula, critical distance for energy transfer was calculated. The CIE co-ordinates, CCT, colour purity and luminescence decay of the prepared phosphors were also calculated. These results offer the prepared phosphor as a suitable candidate for various photonic applications. - Highlights: • Sr_0_._5Ca_0_._5TiO_3: x Pr"3"+ perovskite structured phosphors were synthesized. • Under UV excitation, the PL spectra show strong reddish-orange emission. • The emission from "3P_J levels of Pr"3"+ were absent due to the presence of IVCT band. • Concentration quenching due to dipole–dipole interaction was observed. • For x = 0.1, sample shows a maximum emission intensity with 91.7% colour purity.

  12. An efficient HW and SW design of H.264 video compression, storage and playback on FPGA devices for handheld thermal imaging systems

    Science.gov (United States)

    Gunay, Omer; Ozsarac, Ismail; Kamisli, Fatih

    2017-05-01

    Video recording is an essential property of new generation military imaging systems. Playback of the stored video on the same device is also desirable as it provides several operational benefits to end users. Two very important constraints for many military imaging systems, especially for hand-held devices and thermal weapon sights, are power consumption and size. To meet these constraints, it is essential to perform most of the processing applied to the video signal, such as preprocessing, compression, storing, decoding, playback and other system functions on a single programmable chip, such as FPGA, DSP, GPU or ASIC. In this work, H.264/AVC (Advanced Video Coding) compatible video compression, storage, decoding and playback blocks are efficiently designed and implemented on FPGA platforms using FPGA fabric and Altera NIOS II soft processor. Many subblocks that are used in video encoding are also used during video decoding in order to save FPGA resources and power. Computationally complex blocks are designed using FPGA fabric, while blocks such as SD card write/read, H.264 syntax decoding and CAVLC decoding are done using NIOS processor to benefit from software flexibility. In addition, to keep power consumption low, the system was designed to require limited external memory access. The design was tested using 640x480 25 fps thermal camera on CYCLONE V FPGA, which is the ALTERA's lowest power FPGA family, and consumes lower than 40% of CYCLONE V 5CEFA7 FPGA resources on average.

  13. Reddish orange long afterglow phosphor Ca2SnO4:Sm3+prepared by sol-gel method

    International Nuclear Information System (INIS)

    Ju Zhenghua; Zhang Shuihe; Gao Xiuping; Tang Xiaoliang; Liu Weisheng

    2011-01-01

    Highlights: → A promising reddish orange emissive long afterglow phosphor Ca 2 SnO 4 :Sm 3+ prepared by sol-gel method was firstly reported. → The optics properties of Ca 2 SnO 4 :Sm 3+ were discussed. → Very useful tool, thermoluminscent technique was chosen to investigate the traps in the material. The results of thermoluminscent spectra indicating that the depth and number of traps are critical factors in determining their performance. → Furthermore, the phosphorescence mechanism was discussed successfully. → This work provides a potential approach to develop reddish orange light emitting long afterglow phosphor. - Abstract: A reddish orange light emissive long afterglow phosphor, Ca 2 SnO 4 :Sm 3+ was prepared by sol-gel method at lower temperature. The synthesized phosphors were characterized by X-ray diffraction, scanning electron micrograph images, photoluminescence spectra, afterglow decay curves and thermoluminescence spectra. Three emission peaks locate at 565 nm, 609 nm and 655 nm corresponding to CIE chromaticity coordinates of x = 0.53 and y = 0.47, which indicates the reddish orange light emitting. The fluorescent intensity and the afterglow characteristic depends on the concentration of Sm 3+ and the optimized concentration is 1.5 mol%. The afterglow decay curves are well fitted with triple-exponential decay models. The thermoluminescence glow curves show that the Sm 3+ induces suitable trap depth and result in the long afterglow phenomenon, and the corresponding increase or decrease in afterglow is associated with trap concentration, nearly no change in trap depth. The 1.5 mol% Sm 3+ -doped Ca 2 SnO 4 sample has the biggest trap concentration and exhibit the best afterglow characteristic, its' afterglow time is about 1 h. The phosphorescence mechanism of this long afterglow phosphor was discussed.

  14. Energy storage

    International Nuclear Information System (INIS)

    2012-01-01

    After having outlined the importance of energy storage in the present context, this document outlines that it is an answer to economic, environmental and technological issues. It proposes a brief overview of the various techniques of energy storage: under the form of chemical energy (hydrocarbons, biomass, hydrogen production), thermal energy (sensitive or latent heat storage), mechanical energy (potential energy by hydraulic or compressed air storage, kinetic energy with flywheels), electrochemical energy (in batteries), electric energy (super-capacitors, superconductor magnetic energy storage). Perspectives are briefly evoked

  15. Digital data storage of core image using high resolution full color core scanner; Kokaizodo full color scanner wo mochiita core image no digital ka

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, W; Ujo, S; Osato, K; Takasugi, S [Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan)

    1996-05-01

    This paper reports on digitization of core images by using a new type core scanner system. This system consists of a core scanner unit (equipped with a CCD camera), a personal computer and ancillary devices. This is a modification of the old type system, with measurable core length made to 100 cm/3 scans, and resolution enhanced to 5100 pixels/m (1024 pixels/m in the old type). The camera was changed to that of a color specification, and the A/D conversion was improved to 24-bit full color. As a result of carrying out a detail reproduction test on digital images of this core scanner, it was found that objects can be identified at a level of about the size of pixels constituting the image in the case when the best contrast is obtained between the objects and the background, and that in an evaluation test on visibility of concaves and convexes on core surface, reproducibility is not very good in large concaves and convexes. 2 refs., 6 figs.

  16. Image quality and dose management in digital radiography: A new paradigm for optimisation

    International Nuclear Information System (INIS)

    Busch, H. P.; Faulkner, K.

    2005-01-01

    The advent of digital imaging in radiology, combined with the explosive growth of technology, has dramatically improved imaging techniques. This has led to the expansion of diagnostic capabilities, both in terms of the number of procedures and their scope. Throughout the world, film/ screen radiography systems are being rapidly replaced with digital systems. Many progressive medical institutions have acquired, or are considering the purchase of computed radiography systems with storage phosphor plates or direct digital radiography systems with flat panel detectors. However, unknown to some users, these devices offer a new paradigm of opportunity and challenges. Images can be obtained at a lower dose owing to the higher detective quantum efficiency (DQE). These fundamental differences in comparison to conventional film/screens necessitate the development of new strategies for dose and quality optimisations. A set of referral criteria based upon three dose levels is proposed. (authors)

  17. Creation of a Geant4 Muon Tomography Package for Imaging of Nuclear Fuel in Dry Cask Storage

    Energy Technology Data Exchange (ETDEWEB)

    Tsoukalas, Lefteri H. [Purdue Univ., West Lafayette, IN (United States)

    2016-03-01

    This is the final report of the NEUP project “Creation of a Geant4 Muon Tomography Package for Imaging of Nuclear Fuel in Dry Cask Storage”, DE-NE0000695. The project started on December 1, 2013 and this report covers the period December 1, 2013 through November 30, 2015. The project was successfully completed and this report provides an overview of the main achievements, results and findings throughout the duration of the project. Additional details can be found in the main body of this report and on the individual Quarterly Reports and associated Deliverables of the project, uploaded in PICS-NE.

  18. Computed radiography imaging plates and associated methods of manufacture

    Science.gov (United States)

    Henry, Nathaniel F.; Moses, Alex K.

    2015-08-18

    Computed radiography imaging plates incorporating an intensifying material that is coupled to or intermixed with the phosphor layer, allowing electrons and/or low energy x-rays to impart their energy on the phosphor layer, while decreasing internal scattering and increasing resolution. The radiation needed to perform radiography can also be reduced as a result.

  19. Rare Earth Doped Lanthanum Calcium Borate Polycrystalline Red Phosphors

    Directory of Open Access Journals (Sweden)

    H. H. Xiong

    2014-01-01

    Full Text Available Single-phased Sm3+ doped lanthanum calcium borate (SmxLa2−xCaB10O19, SLCB, x=0.06 polycrystalline red phosphor was prepared by solid-state reaction method. The phosphor has two main excitation peaks located at 398.5 nm and 469.0 nm, which are nicely in accordance with the emitting wavelengths of commercial near-UV and blue light emitting diode chips. Under the excitation of 398.0 nm, the dominant red emission of Sm3+ in SLCB phosphor is centered at 598.0 nm corresponding to the transition of 4G5/2 → 6H7/2. The Eu3+ fluorescence in the red spectral region is applied as a spectroscopic probe to reveal the local site symmetry in the host lattice and, hence, Judd-Ofelt parameters Ωt  (t=2, 4 of Eu3+ in the phosphor matrix are derived to be 3.62×10-20 and 1.97×10-20 cm2, indicating a high asymmetrical and strong covalent environment around rare earth luminescence centers. Herein, the red phosphors are promising good candidates employed in white light emitting diodes (LEDs illumination.

  20. Laser discrimination by stimulated emission of a phosphor

    Science.gov (United States)

    Mathur, V. K.; Chakrabarti, K.

    1991-01-01

    A method for discriminating sources of UV, near infrared, and far infrared laser radiation was discovered. This technology is based on the use of a single magnesium sulfide phosphor doubly doped with rare earth ions, which is thermally/optically stimulated to generate colors correlatable to the incident laser radiation. The phosphor, after initial charging by visible light, exhibits green stimulated luminescence when exposed to a near infrared source (Nd: YAG laser). On exposure to far infrared sources (CO2 laser) the phosphor emission changes to orange color. A UV laser produces both an orange red as well as green color. A device using this phosphor is useful for detecting the laser and for discriminating between the near infrared, far infrared, and UV lasers. The technology is also capable of infrared laser diode beam profiling since the radiation source leaves an imprint on the phosphor that can be photographed. Continued development of the technology offers potential for discrimination between even smaller bandwidths within the infrared spectrum, a possible aid to communication or wavemixing devices that need to rapidly identify and process optical signals.

  1. Neutron storage

    International Nuclear Information System (INIS)

    Strelkov, A.V.

    2004-01-01

    The report is devoted to neutron storage (NS) and describes the history of experiments on the NS development. Great attention is paid to ultracold neutron (UCN) storage. The experiments on the UCN generation, transport, spectroscopy, storage and detection are described. Experiments on searching the UCN electric-dipole moment and electric charge are continued. Possible using of UCN for studying the nanoparticles is discussed [ru

  2. Energy storage

    International Nuclear Information System (INIS)

    Odru, P.

    2010-01-01

    This book proposes a broad overview of the technologies developed in the domains of on-board electricity storage (batteries, super-capacitors, flywheels), stationary storage (hydraulic dams, compressed air, batteries and hydrogen), and heat storage (sensible, latent and sorption) together with their relative efficiency, their expected developments and what advantages they can offer. Eminent specialists of this domain have participated to the redaction of this book, all being members of the Tuck's Foundation 'IDees' think tank. (J.S.)

  3. Energy storage

    CERN Document Server

    Brunet, Yves

    2013-01-01

    Energy storage examines different applications such as electric power generation, transmission and distribution systems, pulsed systems, transportation, buildings and mobile applications. For each of these applications, proper energy storage technologies are foreseen, with their advantages, disadvantages and limits. As electricity cannot be stored cheaply in large quantities, energy has to be stored in another form (chemical, thermal, electromagnetic, mechanical) and then converted back into electric power and/or energy using conversion systems. Most of the storage technologies are examined: b

  4. Tritium storage

    International Nuclear Information System (INIS)

    Hircq, B.

    1989-01-01

    A general synthesis about tritium storage is achieved in this paper and a particular attention is given to practical application in the Fusion Technology Program. Tritium, storage under gaseous form and solid form are discussed (characteristics, advantages, disadvantages and equipments). The way of tritium storage is then discussed and a choice established as a function of a logic which takes into account the main working parameters

  5. Process for recovery of uranium from wet process phosphoric acid

    International Nuclear Information System (INIS)

    Wiewiorowski, T.K.; Thornsberry, W.L. Jr.

    1978-01-01

    Process is claimed for the recovery of uranium from wet process phosphoric acid solution in which an organic extractant, containing uranium values and dissolved iron impurities and comprising a dialkylphosphoric acid and a trialkylphosphine oxide dissolved in a water immiscible organic solvent, is contacted with a substantially iron-free dilute aqueous phosphoric acid to remove said iron impurities. The removed impurities are bled from the system by feeding the resulting iron-loaded phosphoric acid to a secondary countercurrent uranium extraction operation from which they leave as part of the uranium-depleted acid raffinate. Also, process for recovering uranium in which the extractant, after it has been stripped of uranium values by aqueous ammonium carbonate, is contacted with a dilute aqueous acid selected from the group consisting of H 2 SO 4 , HCl, HNO 3 and iron-free H 3 PO 4 to improve the extraction efficiency of the organic extractant

  6. Stacking dependence of carrier transport properties in multilayered black phosphorous

    Science.gov (United States)

    Sengupta, A.; Audiffred, M.; Heine, T.; Niehaus, T. A.

    2016-02-01

    We present the effect of different stacking orders on carrier transport properties of multi-layer black phosphorous. We consider three different stacking orders AAA, ABA and ACA, with increasing number of layers (from 2 to 6 layers). We employ a hierarchical approach in density functional theory (DFT), with structural simulations performed with generalized gradient approximation (GGA) and the bandstructure, carrier effective masses and optical properties evaluated with the meta-generalized gradient approximation (MGGA). The carrier transmission in the various black phosphorous sheets was carried out with the non-equilibrium green’s function (NEGF) approach. The results show that ACA stacking has the highest electron and hole transmission probabilities. The results show tunability for a wide range of band-gaps, carrier effective masses and transmission with a great promise for lattice engineering (stacking order and layers) in black phosphorous.

  7. Persistent phosphors for painting, medical and biological applications

    International Nuclear Information System (INIS)

    Nazarov, M.

    2013-01-01

    Multiphase micro and nanoparticle persistent phosphors are synthesized and applied for different fields including painting, medical and biological investigations. A lot of examples show a broad range of applications of persistent luminescence from bulk materials to high tech products, especially in medicine. The development of high efficiency nanosized phosphor makes it possible to propose persistent materials as very good candidates for photodynamic therapy of cancer. An artificial block from slag, concrete, and sand covered with SrAl 2 O 4 :Eu 2+ , Dy 3+ based phosphor is prepared, and a new direction in biology for algae cultivation and artificial reef is discussed. For the first time, underwater luminescence is experimentally studied under real sea conditions. Bright blue-green long-lasting afterglow is registered at a depth of 5 m. The fishes are attracted by the light of the artificial reef. (author)

  8. Recovery of zinc in phosphor wastes via electrokinetic treatments

    International Nuclear Information System (INIS)

    Yu, M.Y.; Wang, H. Paul; Chen, C.Y.; Hsiung, T.-L.; Wei, Yu-Ling; Tai, H.-S.; Chiang, K.-C.

    2007-01-01

    Speciation of zinc in phosphor wastes during electrokinetic treatments has been studied by in situ X-ray absorption near edge structure (XANES) spectroscopy in the present work. The least-square fits of the in situ XANES spectra show that the major zinc species in the phosphor waste are ZnS (77%), ZnO (10%), and Zn(OH) 2 (13%). During the electrokinetic treatment for 90 min, 25% of ZnS and 4% of ZnO are dissolved. About 42% of zinc is enriched on the cathode under the electric field (5 V/cm). Prolonging the electrokinetic treatment time to 4 h under the electric field of 5 V/cm, at least 80% of zinc in the phosphor waste can be recovered

  9. White-electroluminescent device with horizontally patterned blue/yellow phosphor-layer structure

    International Nuclear Information System (INIS)

    Won Park, Boo; Sik Choi, Nam; Won Park, Kwang; Mo Son, So; Kim, Jong Su; Kyun Shon, Pong

    2007-01-01

    White-electroluminescent (EL) devices with stripe-patterned and square-patterned phosphor-layer structures are fabricated through a screen printing method: electrode/BaTiO 3 insulator layer/patterned blue ZnS:Cu, Cl and yellow ZnS:Cu, Mn phosphor layer/ITO PET substrate. The luminous intensities of EL devices with stripe-patterned and square-patterned phosphor-layer structures are 33% and 23% higher than a conventional device with the phosphor-layer structure without any patterns using the phosphor blend. It can be explained in terms of the absorption of the emitted blue light of blue phosphor layer by the yellow-emitting phosphor layer. The EL device of our patterned phosphor-layer structure gives the possibility to enhance the luminance

  10. Energy response of imaging plates to radiation beams from standard beta sources, ortho-voltage and cobalt-60 units and linear accelerators

    Science.gov (United States)

    Gonzalez, Albin Leonel

    The response to different types of radiation beams of commercial imaging plates used for diagnostic computed radiography has been investigated in this work. Imaging plates are designed with a phosphor layer which after been irradiated; information is stored in the form of photostimulable luminescence (PSL) centers. Initial measurements of the dose distribution of a radioactive stent with the imaging plates showed similar results to those with radiochromic films, but with much shorter exposure time due to their higher sensitivity. In order to investigate further their response, the imaging plates were irradiated with calibrated beams from: standard beta sources, orthovoltage and Co-60 units and therapy linear accelerator. Initially it was found that the energy to create the storage centers (generation efficiency) when irradiated with the three standard beta sources (225 keV to 2.28 MeV) was the same. For the rest of the calibrated beams an in house reader system was built in order to perform the bleaching of the plates with a He-Ne laser (632.8 nm) and to measure the absolute number of the emitted PSL photons (storage centers produced). Bleaching curves were then obtained for different exposure times for each beam. From the graph of the calculated area under the bleaching curves (total number of storage center) versus the absorbed dose to the phosphor layer it was possible to calculate the energy to create the storage centers (generation efficiency) for photon and electron beams. The dose to the phosphor layer was calculated in the case of the electron beams following a scaling procedure, while in the case of the photon beams Monte Carlo simulations were performed. For the photons beams the measurement of the generation efficiency energy of 126 +/- 8% eV per PSL storage center, coincide with measurements using a different approach (˜148 eV) by previous investigators. The generation efficiency for the electron beam was 807 +/- 3% eV, no reference was found in the

  11. Method for the recovery of uranium from a concentrate using pure phosphoric acid

    International Nuclear Information System (INIS)

    1980-01-01

    Procedure for the recovery of an uranium bearing concentrate and pure phosphoric acid from a wet process phosphoric acid from the treatment fluid with a precipitation means in conjunction with an organic diluent, the thus formed precipitate to separate and from the remaining mixture of phosphoric acid and diluent the phosphoric acid to extract, characterised in that one applies an inorganic fluorine compound. (G.C.)

  12. Reactivity of the cadmium ion in concentrated phosphoric acid solutions.

    Science.gov (United States)

    De Gyves, J; Gonzales, J; Louis, C; Bessiere, J

    1989-07-01

    The solvation transfer coefficients which characterize the changes of ion reactivity with phosphoric acid concentration have been calculated for cadmium from the constants of the successive chloride complexes, and for silver and diethyldithiophosphate from potentiometric measurements. They evidence the strong desolvation of the cadmium species in concentrated phosphoric acid media, causing a remarkable increase of its reactivity. They allow the results of liquid-liquid extraction, precipitation and flotation reactions to be correctly interpreted and their changes to be foreseen when the reagents are modified.

  13. Phosphoric acid fuel cell R and D activities at KACST

    International Nuclear Information System (INIS)

    Ghouse, M.; Aba-Oud, H.; Ba-Junaid, M.; Al-Garni, M.; Quadri, M.I.

    1993-01-01

    The PAFC (Phosphoric Acid Fuel Cell) activities are directed towards the development of components of single cell and experimental stacks at KACST. The main aim of the present task is to design and construct a 1 kW PAFC Stack and demonstrate it by integrating with an electrolyser using a DC current generated by a photovoltaic power source. This paper describes the preparation of porous teflon bonded gas diffusion carbon electrodes and their evaluation as single phosphoric acid fuel cells using hydrogen as a fuel and oxygen/air as an oxidant. 6 figs., 2 tabs., 15 refs

  14. Cadmium elemination from phosphoric acid by ionic flotation

    International Nuclear Information System (INIS)

    Brikci-Nigassa, Mounir; Hamouche, Hafida

    1995-11-01

    The ion flotation process for the recovery of cadmium from wet phosphoric acid (30%P2O5) has been studied. This technique combines a chemical recation between the collector and the cadmium to form a precipitate (sublate) which is carried to the surface of the solution by air bubbles. the resulting foam containing the cadmium may then separated from solution. The influence of parameters such as collector and cadmium concentration as well as iron content have been investigated for the case a synthetic acid (30% P2O5). The result have been applied to the industrial phosphoric acid produced from Djebel Onk's phosphates (Algeria)

  15. Transport of phosphoric acid through supported liquid membrane

    International Nuclear Information System (INIS)

    Zayzafoon, G.; Yassine, T.; Baidoun, R.

    2003-01-01

    The transport of phosphhoric acid through liquid membranes of amylalkohol, 1-octanol and 2-octanol was studied. It was found that phosphoric acid is transfered from feed side to strip side and the transport increased with the concentration of phosphoric acid up to 5M. The permeability in each membrane was determined for 5M phosphoic acid. It was found that the permeability values are 1.45 x 10 1 0 m 2 s 1 for amylakohol and ∼ 1x10 1 0 m 2 s 1 for each of 1-octanol and 2-octanol

  16. Properties of precipitates formed during ammonization of extractional phosphoric acid

    International Nuclear Information System (INIS)

    Zakharova, B.S.; Komissarova, L.N.; Naumov, S.V.; Traskin, V.Yu.

    1992-01-01

    Dimensions of precipitated rare-earth phosphate particles -(0.1 μm)- are near the boundary of colloidal system sedimentation stability range at neutralization of extraction phosphoric acid. Thus, formation of multiple aggregates of colloidal particles results in immediate sedimentation of the precipitate. Processes occurring within the system may be described using second order reaction equation. Average efficient size of precipitates grows at reduction of reaction mixture pH. About 30% of rare-earth elements and yttrium in the extraction phosphoric acid is extracted from it; concentration of rare-earth elements, yttrium and scandium in precipitate is maximum 2 mass. %

  17. Effect of Distinct Lifestyle Interventions on Mobilization of Fat Storage Pools: CENTRAL Magnetic Resonance Imaging Randomized Controlled Trial.

    Science.gov (United States)

    Gepner, Yftach; Shelef, Ilan; Schwarzfuchs, Dan; Zelicha, Hila; Tene, Lilac; Yaskolka Meir, Anat; Tsaban, Gal; Cohen, Noa; Bril, Nitzan; Rein, Michal; Serfaty, Dana; Kenigsbuch, Shira; Komy, Oded; Wolak, Arik; Chassidim, Yoash; Golan, Rachel; Avni-Hassid, Hila; Bilitzky, Avital; Sarusi, Benjamin; Goshen, Eyal; Shemesh, Elad; Henkin, Yaakov; Stumvoll, Michael; Blüher, Matthias; Thiery, Joachim; Ceglarek, Uta; Rudich, Assaf; Stampfer, Meir J; Shai, Iris

    2018-03-13

    We aimed to assess whether distinct lifestyle strategies can differentially affect specific body adipose depots. We performed an 18-month randomized controlled trial among 278 sedentary adults with abdominal obesity (75%) or dyslipidemia in an isolated workplace with a monitored provided lunch. Participants were randomized to isocaloric low-fat or Mediterranean/low-carbohydrate (MED/LC) diet+28 g walnuts/day with/without added moderate physical activity (PA; 80% aerobic; supervised/free gym membership). Overall primary outcome was body fat redistribution, and the main specific end point was visceral adipose tissue (VAT). We further followed the dynamics of different fat depots (deep and superficial subcutaneous, liver, pericardial, muscle, pancreas, and renal sinus) by magnetic resonance imaging. Of 278 participants (age, 48 years, 89% men, body mass index, 30.8 kg/m 2 ), 86% completed the trial with good adherence. The low-fat group preferentially decreased reported fat intake (-21.0% versus -11.5% for the MED/LC; P carbohydrates intake (-39.5% versus -21.3% for the low-fat group; P loss was indifferent, exercise attenuated the waist circumference rebound with the greatest effect in the MED/LC PA+ group ( P fats declines were higher than pancreatic and femur intermuscular fats (1% to 2%) loss. Independent of weight loss, PA + with either diet had a significantly greater effect on decreasing VAT (mean of difference, -6.67cm 2 ; 95% confidence interval, -14.8 to -0.45) compared with PA - . The MED/LC diet was superior to the low-fat diet in decreasing intrahepatic, intrapericardial, and pancreatic fats ( P fats were not differentially altered by lifestyle interventions but by weight loss per se. In multivariate models further adjusted for weight loss, losing VAT or intrahepatic fat was independently associated with improved lipid profile, losing deep subcutaneous adipose tissue with improved insulin sensitivity, and losing superficial subcutaneous adipose tissue

  18. Purification of di-nonyl phenyl phosphoric acid (DNPPA) for synergistic extraction of uranium from strong phosphoric acid

    International Nuclear Information System (INIS)

    Singh, D.K.; Vijayalakshmi, R.; Singh, H.; Sharma, J.N.; Ruhela, R.

    2009-01-01

    Di-nonyl phenyl phosphoric acid (DNPPA) obtained from various synthesis methods is always associated with impurities such as mono-nonyl phenyl phosphoric acid and nonyl phenol which need to be separated for its effective use in the extraction of uranium from strong phosphoric acid. Two methods of purification namely liquid-solid separation method using neodymium salt and liquid-liquid separation method using methylene glycol have been described. In the liquid solid separation method the purity of DNPPA obtained was about 95% with less than 1.0% monoester, however it heavily suffers in the recovery aspect which is of the order of 50-60%. The methylene glycol treatment method, results in high purity and recovery of the product. Purity obtained was about 95.0% diester and less than 0.5% monoester and recovery was more than 90%. Analysis of DNPPA was done by potentiometric titration method using autotitrator. (author)

  19. Probe Storage

    NARCIS (Netherlands)

    Gemelli, Marcellino; Abelmann, Leon; Engelen, Johannes Bernardus Charles; Khatib, M.G.; Koelmans, W.W.; Zaboronski, Olog; Campardo, Giovanni; Tiziani, Federico; Laculo, Massimo

    2011-01-01

    This chapter gives an overview of probe-based data storage research over the last three decades, encompassing all aspects of a probe recording system. Following the division found in all mechanically addressed storage systems, the different subsystems (media, read/write heads, positioning, data

  20. Process for recovering yttrium and lanthanides from wet-process phosphoric acid

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, J.A.; Weterings, C.A.

    1983-06-28

    Process for recovering yttrium and lanthanides from wet-process phosphoric acid by adding a flocculant to the phosphoric acid, separating out the resultant precipitate and then recovering yttrium and lanthanides from the precipitate. Uranium is recovered from the remaining phosphoric acid.

  1. Radiology image orientation processing for workstation display

    Science.gov (United States)

    Chang, Chung-Fu; Hu, Kermit; Wilson, Dennis L.

    1998-06-01

    Radiology images are acquired electronically using phosphor plates that are read in Computed Radiology (CR) readers. An automated radiology image orientation processor (RIOP) for determining the orientation for chest images and for abdomen images has been devised. In addition, the chest images are differentiated as front (AP or PA) or side (Lateral). Using the processing scheme outlined, hospitals will improve the efficiency of quality assurance (QA) technicians who orient images and prepare the images for presentation to the radiologists.

  2. 46 CFR 153.558 - Special requirements for phosphoric acid.

    Science.gov (United States)

    2010-10-01

    ... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and... containment system must be: (a) Lined with natural rubber or neoprene; (b) Lined with a material approved for phosphoric acid tanks by the Commandant (CG-522); or (c) Made of a stainless steel that resists corrosion by...

  3. Characterization of metallic surfaces in phosphorous-bronze ordered packings

    International Nuclear Information System (INIS)

    Sandru, Claudia; Titescu, Gh.

    1997-01-01

    Copper and its alloys, particularly the phosphorous bronze, are characterized by a high water wettability as compared with other materials. This feature led to utilization of phosphorous bronze in fabrication of contact elements, a packing type equipping the distillation columns. For heavy water separation by isotopic distillation under vacuum, ordered packings of phosphorous bronze networks were fabricated. The superior performances of these packings are determined by the material and also by the geometrical form and the state of the metallic surface. Thus, a procedure of evaluating the wettability has been developed, based on tests of the network material. The results of the tests constitute a criterion of rating the functional performances of packings, particularly of their efficiencies. Also, investigation techniques of the chemical composition and of the thickness of superficial layer on the packing were developed. It was found that the packing surface presents a layer of about 5-20 μm formed mainly by oxides of copper, tin, and, depending on the packing treatment, of oxides of other elements coming from the treatment agent. The paper presents characterization of phosphorous bronze treated with potassium permanganate, a specific treatment for improving the functional performances of the packings used in the heavy water concentration and re-concentration installations

  4. Comparison of different phosphorous adsorption models in acid ...

    African Journals Online (AJOL)

    This study was designed to compare the phosphorous fixation capacity of three soils series named Tyele, Minkonmingon and Mekoto in the south region of Cameroon and to determine the soil properties that are the main predictors of the P activity of those soils. Five adsorption equations viz. Linear, Langmuir, Van Huay, ...

  5. Fluoride removal performance of phosphoric acid treated lime ...

    African Journals Online (AJOL)

    Fluoride in drinking water above permissible levels is responsible for dental and skeletal fluorosis. In this study, removal of fluoride ions from water using phosphoric acid treated lime was investigated in continuous and point-of-use system operations. In the continuous column operations, fluoride removal performance was ...

  6. Method for recovery of uranium from phosphoric acid

    International Nuclear Information System (INIS)

    Duarte Neto, J.

    1984-01-01

    The results of a method for recuperation of uranium from phosphoric acid by humid way are presented. The extracting mixture used was di-ethylhexylphosphoric acid (D 2 EHPA) and trioctylphosphine oxide (TOPO). An installation in micro-pilot scale was made to get and visualize data for continuous process. (M.A.C.) [pt

  7. Effect of nitrogen and phosphorous on Farm Plantations in various ...

    African Journals Online (AJOL)

    use

    of different suitable species of plants. The results of the soil analysis of various Agro ecological zones and the consequent recommendation of the associated suitable species, aids the agrofarmers to pick out the best possible option. Key words: Soil analysis, agro-ecological zones, agroforestry, nitrogen and phosphorous.

  8. Corrosion of graphite composites in phosphoric acid fuel cells

    Science.gov (United States)

    Christner, L. G.; Dhar, H. P.; Farooque, M.; Kush, A. K.

    1986-01-01

    Polymers, polymer-graphite composites and different carbon materials are being considered for many of the fuel cell stack components. Exposure to concentrated phosphoric acid in the fuel cell environment and to high anodic potential results in corrosion. Relative corrosion rates of these materials, failure modes, plausible mechanisms of corrosion and methods for improvement of these materials are investigated.

  9. Natural Radiation in byproducts of the production of phosphoric acid

    International Nuclear Information System (INIS)

    Silveira, Marcilei A. Guazzelli da; Cardoso, L.L.; Medina, N.H.

    2014-01-01

    Natural radiation is the largest source of radiation exposure to which man is subject. It is formed basically by cosmic radiation and the radionuclides present in the Earth crust, as 40 K and the elements of the decay series of 232 Th and 238 U. Phosphate ores, which constitutes the raw material for the production of phosphoric acid, have a high rate of natural radiation from the decay series of 232 Th and 238 U. Phosphogypsum, which is naturally radioactivity, is a by-product of the production of phosphoric acid by the wet method. For each ton of phosphoric acid it is produced about 4.5 tons of phosphogypsum. This work presents the analysis of samples collected in all stages of the manufacturing process of phosphoric acid, which generates the phosphogypsum. Gamma-ray spectrometry was used to measure the concentration of the elements of the decay series of 232 Th and 238 U. All analyzed samples showed a high concentration of radionuclides, promoting the need for further steps in the process in order to reduce the presence of such radionuclides in the phosphogypsum. The results indicate the radionuclide 238 U has higher contribution in some samples of the intermediate stages of the process. All samples exceeded the international average range of human exposure to terrestrial gamma radiation, which is 0.3 to 1.0 mSv/year. (author)

  10. Extraction studies on rare earths using dinonyl phenyl phosphoric acid

    International Nuclear Information System (INIS)

    Anitha, M.; Singh, D.K.; Kotekar, M.K.; Vijayalakshmi, R.; Singh, H.

    2011-01-01

    Rare earths are widely used in phosphor materials, magnetic substances, alloys, catalyst, lasers, superconductors, solid oxide fuel cells and in nuclear applications. The high value of these elements depends on their effective separation into high purity compounds. The separation into individual rare earths is very difficult to achieve, due to the very low separation factors between two adjacent rare earths arising due to similar chemical properties. Taking the advantage of variation in basicity, the separation is generally accomplished by solvent extraction or ion exchange. There are several references on the separation of rare earth in different media employing various types of extractants such as 2-ethylhexyl 2-ethyhexylphosphonic acid (EHEHPA) and di-2-ethyl hexyl phosphoric acid (D2EHPA) which have been widely used for the separation and purification of rare earths. Dinonyl phenyl phosphoric acid (DNPPA) is an organo phosphorus extractant (pKa = 2.54) and is an aromatic analogue of D2EHPA, which extracts metal ion by cation exchange mechanism. DNPPA was explored to recover rare earths from phosphate media such as wet process phosphoric acid and merchant grade acid. However, there is no information available in literature on DNPPA for RE extraction from chloride medium. Therefore, an attempt has been made in the present study to investigate the feasibility of using DNPPA for extraction of La(III), Dy(III) and Y(III) from chloride medium

  11. Spectral modulation through controlling anions in nanocaged phosphors

    NARCIS (Netherlands)

    Bian, H.; Liu, Y.; Yan, D.; Zhu, H.; Liu, C.; Xu, C.S.; Liu, Y.; Zhang, H.; Wang, X.

    2013-01-01

    A new approach has been proposed and validated to modulate the emission spectra of europium-doped 12CaO center dot 7Al(2)O(3) phosphors by tuning the nonradiative and radiative transition rates, realized by controlling the sort and amount of the encaged anions. A single wavelength at 255 nm can

  12. Kinetic parameters and TL mechanism in cadmium tetra borate phosphor

    International Nuclear Information System (INIS)

    Annalakshmi, O.; Jose, M.T.; Sridevi, J.; Venkatraman, B.; Amarendra, G.; Mandal, A.B.

    2014-01-01

    Polycrystalline powder samples of cadmium tetra borate were synthesized by a simple solid state sintering technique and gamma irradiated sample showed a simple Thermoluminescence (TL) glow peak around 460 K. The TL kinetic parameters of gamma irradiated phosphor were determined by initial rise (IR), isothermal decay (ID), peak shape (PS), variable heating rate (VHR) and glow curve de-convolution method. The kinetic parameters such as activation energy (E), frequency factor (s) and order of kinetics (b) were calculated by IR, ID, PS and VHR methods are in the order of ∼1.05 eV, 10 9 –10 12 s −1 and 1.58, respectively. From the results of TL and PL emission studies carried out on the phosphor revealed that the defect centers related to TL is different from that for PL. EPR measurements were carried out to identify the defect centers formed in cadmium tetra borate phosphor on gamma irradiation. Based on EPR studies the mechanism for TL process in cadmium tetra borate is proposed in this paper -- Highlights: • Polycrystalline powder samples of undoped cadmium tetra borate synthesized. • Cadmium tetra borate phosphor exhibits a dosimetric peak at 458 K. • Kinetic parameters of the trap responsible for TL evaluated. • TL mechanism is proposed from TL to EPR correlation studies

  13. Kinetic parameters and TL mechanism in cadmium tetra borate phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Annalakshmi, O. [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Jose, M.T., E-mail: mtj@igcar.gov.in [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Sridevi, J. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai 600 020, Tamilnadhu (India); Venkatraman, B. [Radiological Safety Division, Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Amarendra, G. [Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Mandal, A.B. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai 600 020, Tamilnadhu (India)

    2014-03-15

    Polycrystalline powder samples of cadmium tetra borate were synthesized by a simple solid state sintering technique and gamma irradiated sample showed a simple Thermoluminescence (TL) glow peak around 460 K. The TL kinetic parameters of gamma irradiated phosphor were determined by initial rise (IR), isothermal decay (ID), peak shape (PS), variable heating rate (VHR) and glow curve de-convolution method. The kinetic parameters such as activation energy (E), frequency factor (s) and order of kinetics (b) were calculated by IR, ID, PS and VHR methods are in the order of ∼1.05 eV, 10{sup 9}–10{sup 12} s{sup −1} and 1.58, respectively. From the results of TL and PL emission studies carried out on the phosphor revealed that the defect centers related to TL is different from that for PL. EPR measurements were carried out to identify the defect centers formed in cadmium tetra borate phosphor on gamma irradiation. Based on EPR studies the mechanism for TL process in cadmium tetra borate is proposed in this paper -- Highlights: • Polycrystalline powder samples of undoped cadmium tetra borate synthesized. • Cadmium tetra borate phosphor exhibits a dosimetric peak at 458 K. • Kinetic parameters of the trap responsible for TL evaluated. • TL mechanism is proposed from TL to EPR correlation studies.

  14. Energy storage

    Energy Technology Data Exchange (ETDEWEB)

    1962-07-01

    The papers on energy storage problems, given to the United Nations Conference on New Sources of Energy, Rome, 1961, are reviewed. Many aspects of the subject are discussed: comparisons between the costs of storing energy in batteries and in fuel cells; the use, efficiency and expected improvement of fuel cells; the principles involved in the chemical conversion of solar energy to chemical energy; the use of metal hydride fuel cells; the chemical conversion and storage of concentrated solar energy for which the solar furnace is used for photochemical reactions. Finally, the general costs of storing energy in any form and delivering it are analyzed with particular reference to storage batteries and fuel cells.

  15. Fully automatic and reference-marker-free image stitching method for full-spine and full-leg imaging with computed radiography

    Science.gov (United States)

    Wang, Xiaohui; Foos, David H.; Doran, James; Rogers, Michael K.

    2004-05-01

    Full-leg and full-spine imaging with standard computed radiography (CR) systems requires several cassettes/storage phosphor screens to be placed in a staggered arrangement and exposed simultaneously to achieve an increased imaging area. A method has been developed that can automatically and accurately stitch the acquired sub-images without relying on any external reference markers. It can detect and correct the order, orientation, and overlap arrangement of the subimages for stitching. The automatic determination of the order, orientation, and overlap arrangement of the sub-images consists of (1) constructing a hypothesis list that includes all cassette/screen arrangements, (2) refining hypotheses based on a set of rules derived from imaging physics, (3) correlating each consecutive sub-image pair in each hypothesis and establishing an overall figure-of-merit, (4) selecting the hypothesis of maximum figure-of-merit. The stitching process requires the CR reader to over scan each CR screen so that the screen edges are completely visible in the acquired sub-images. The rotational displacement and vertical displacement between two consecutive sub-images are calculated by matching the orientation and location of the screen edge in the front image and its corresponding shadow in the back image. The horizontal displacement is estimated by maximizing the correlation function between the two image sections in the overlap region. Accordingly, the two images are stitched together. This process is repeated for the newly stitched composite image and the next consecutive sub-image until a full-image composite is created. The method has been evaluated in both phantom experiments and clinical studies. The standard deviation of image misregistration is below one image pixel.

  16. Synthesis and luminescence properties of Eu"2"+ doped CaSO_4 phosphor

    International Nuclear Information System (INIS)

    Aghalte, G.A.; Dhoble, S.J.; Pawar, N.R.

    2016-01-01

    Eu"2"+ doped CaSO_4 Phosphor were synthesized by precipitation method. PL analysis of Eu"2"+ activated CaSO_4 phosphor exhibited characteristic emission properties; CaSO_4:Eu Phosphor has received considerable attention because of its high sensitivity to X-ray and λ ray irradiation. CaSO_4:Eu phosphor powder was successfully synthesized by the wet chemical co-precipitation method. The structure morphology and luminescent properties of the phosphor were characterized by X-ray diffraction, scanning electron microscopy and photoluminescence spectroscopy

  17. On the feasibility of infrared phosphors in super-slow particle searches

    International Nuclear Information System (INIS)

    Hagstrom, R.; Rugari, A.D.

    1984-01-01

    This chapter proposes that super-slow projectiles will produce ionization signals in media with narrow bandgaps. A specific choice of narrow bandgap phosphors is recommended which would be economically suitable for use as detectors. Topics considered include the possibilities for practical detectors, a description of detectors based on narrow bandgap phosphors, the experimental determination of relevant properties of narrow bandgap phosphors, and the observation of ionizing particles using narrow bandgap phosphors. It is determined that the temperature dependence of the glow of the phosphors is strong enough that a reduction of operating temperature by about 60 C could be sufficient to produce the desired signal to background ratio

  18. Investigation of the synergic effect of some neutral organophosphoric compounds on the extraction of uranium from phosphoric acid solutions by D1-(2-Ethyl Hexyl) phosphoric acid

    International Nuclear Information System (INIS)

    Stas, J.; Khorfan, S.; Koudsi, Y.

    1998-05-01

    The extraction of uranium (VI) from pure phosphoric acid media by D2EHPA/Kerosene has been studied. The mechanism of the extraction was found as follows: The logarithm of the equilibrium constant of the extraction (LogKex) was found (3.06), (3.32), (3.24), (3.3) for the following phosphoric acid concentrations respectively (1), (2), (3), (4) Mol/1, and the enthalpy change DELTA H was found (-100.68 kj/mol). (-76 kj/mol) for (1), (2) mol/1 phosphoric acid concentrations. The synergic effect of TOPO, TBP, and TBPI with DEHPA have been studied during the extraction of uranium from pure phosphoric acid and Syrian commercial phosphoric acid. The synergic effect increases as follows: TBP< TBPI<< TOPO (In pure phosphoric acid), TBPI approx TBP<< TOPO (In Syrian commercial phosphoric acid). The difficulty of extracting uranium (VI) from Syrian commercial phosphoric acid in comparison with pure phosphoric acid is due to the presence of several impurities capable of complexing uranium, and a small amounts of solid and organic matters, all these are factors which reduce the distribution coefficient of uranium. (Author)

  19. Rare earth activated yttrium aluminate phosphors with modulated luminescence.

    Science.gov (United States)

    Muresan, L E; Popovici, E J; Perhaita, I; Indrea, E; Oro, J; Casan Pastor, N

    2016-06-01

    Yttrium aluminate (Y3 A5 O12 ) was doped with different rare earth ions (i.e. Gd(3+) , Ce(3+) , Eu(3+) and/or Tb(3+) ) in order to obtain phosphors (YAG:RE) with general formula,Y3-x-a Gdx REa Al5 O12 (x = 0; 1.485; 2.97 and a = 0.03). The synthesis of the phosphor samples was done using the simultaneous addition of reagents technique. This study reveals new aspects regarding the influence of different activator ions on the morpho-structural and luminescent characteristics of garnet type phosphor. All YAG:RE phosphors are well crystallized powders containing a cubic-Y3 Al5 O12 phase as major component along with monoclinic-Y4 Al2 O9 and orthorhombic-YAlO3 phases as the impurity. The crystallites dimensions of YAG:RE phosphors vary between 38 nm and 88 nm, while the unit cell slowly increase as the ionic radius of the activator increases. Under UV excitation, YAG:Ce exhibits yellow emission due to electron transition in Ce(3+) from the 5d level to the ground state levels ((2) F5/2 , (2) F7/2 ). The emission intensity of Ce(3+) is enhanced in the presence of the Tb(3+) ions and is decreased in the presence of Eu(3+) ions due to some radiative or non-radiative processes that take place between activator ions. By varying the rare earth ions, the emission colour can be modulated from green to white and red. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Advances in computed radiography systems and their physical imaging characteristics

    International Nuclear Information System (INIS)

    Cowen, A.R.; Davies, A.G.; Kengyelics, S.M.

    2007-01-01

    Radiological imaging is progressing towards an all-digital future, across the spectrum of medical imaging techniques. Computed radiography (CR) has provided a ready pathway from screen film to digital radiography and a convenient entry point to PACS. This review briefly revisits the principles of modern CR systems and their physical imaging characteristics. Wide dynamic range and digital image enhancement are well-established benefits of CR, which lend themselves to improved image presentation and reduced rates of repeat exposures. However, in its original form CR offered limited scope for reducing the radiation dose per radiographic exposure, compared with screen film. Recent innovations in CR, including the use of dual-sided image readout and channelled storage phosphor have eased these concerns. For example, introduction of these technologies has improved detective quantum efficiency (DQE) by approximately 50 and 100%, respectively, compared with standard CR. As a result CR currently affords greater scope for reducing patient dose, and provides a more substantive challenge to the new solid-state, flat-panel, digital radiography detectors

  1. Structural and luminescence properties of yellow Y3Al5012:Ce3+ thin film phosphors prepared by Pulsed Laser Deposition

    CSIR Research Space (South Africa)

    Dejene, FB

    2012-07-01

    Full Text Available of the phosphore/epoxy hybrid system is the difficulty of achieving uniform emission of white light from the LED. In order to overcome the challenges of using mixtures of phosphore powders and epoxies thin film phosphore has been used. In this study, YAG phosphore...

  2. Photoluminescence studies on holmium (III) and praseodymium (III) doped calcium borophosphate (CBP) phosphors

    Science.gov (United States)

    Reddy Prasad, V.; Damodaraiah, S.; Devara, S. N.; Ratnakaram, Y. C.

    2018-05-01

    Using solid state reaction method, Ho3+ and Pr3+ doped calcium borophosphate (CBP) phosphors were prepared. These phosphors were characterized using XRD, SEM, FT-IR, 31P solid state NMR, photoluminescence (PL) and decay profiles. Structural details were discussed from XRD and FT-IR spectra. From 31P NMR spectra of these phosphors, mono-phosphate complexes Q0-(PO43-) were observed. Photoluminescence spectra were measured for both Ho3+ and Pr3+ doped calcium borophosphate phosphors and the spectra were studied for different concentrations. Decay curves were obtained for the excited level, 5F4+5S2 of Ho3+ and 1D2 level of Pr3+ in these calcium borophosphate phosphors and lifetimes were measured. CIE color chromaticity diagrams are drawn for these two rare earth ions in calcium borophosphate phosphors. Results show that Ho3+ and Pr3+ doped CBP phosphors might be served as green and red luminescence materials.

  3. Encapsulation of strontium aluminate phosphors to enhance water resistance and luminescence

    International Nuclear Information System (INIS)

    Zhu Yong; Zeng Jianghua; Li Wenyu; Xu Li; Guan Qiu; Liu Yingliang

    2009-01-01

    Strontium aluminate SrAl 2 O 4 :Eu 2+ ,Dy 3+ phosphors are chemically unstable against water or even moisture. To enhance the water resistance of the phosphors, an encapsulation was performed by direct surface reactions with phosphoric acid (H 3 PO 4 ). The morphology, surface structure, surface element composition, water resistance, luminescence, and photoacoustic spectrum of the phosphors before and after encapsulation were discussed. Experimental results showed that phosphors were perfectly encapsulated by amorphous layers in nanoscale and crystalline layers in microscale under different conditions. The water resistance of phosphors was greatly enhanced by the two types of layer. More importantly, the amorphous layers enhanced the luminescence of phosphors markedly. The possible mechanism for the enhancements was also proposed.

  4. Preparation of red phosphor (Y, Gd)BO3:Eu by soft chemistry methods

    International Nuclear Information System (INIS)

    Cui Xiangzhong; Zhuang Weidong; Yu Zhijian; Xia Tian; Huang Xiaowei; Li Hongwei

    2008-01-01

    The three soft chemistry methods were employed to prepare the red phosphor (Y, Gd)BO 3 :Eu, such as coprecipitation-combustion method, salt assisted combustion method and emulsion method. The main factors affecting particle size, particle distribution and luminescent properties of the product were investigated in detail, and as a result, the preparation processes were optimized. The phosphors were characterized by X-ray diffraction (XRD), scanning electronic microscope (SEM), transmission electronic microscope (TEM) and vacuum ultraviolet (VUV) spectra. Results reveal that phosphors with different morphology, small particle size and high luminescence intensity could be obtained by soft chemistry methods. The difference between the luminescence properties of phosphors in this work and commercial rare earth borate phosphor is discussed. The phosphor with grain shape and high luminescence intensity could be prepared by coprecipitation-combustion method, nanophosphor could be prepared by salt assisted combustion method, and spherical phosphor with a narrow size distribution could be obtained by using emulsion method

  5. White light-emitting diodes (LEDs) using (oxy)nitride phosphors

    International Nuclear Information System (INIS)

    Xie, R-J; Hirosaki, N; Sakuma, K; Kimura, N

    2008-01-01

    (Oxy)nitride phosphors have attracted great attention recently because they are promising luminescent materials for phosphor-converted white light-emitting diodes (LEDs). This paper reports the luminescent properties of (oxy)nitride phosphors in the system of M-Si-Al-O-N (M = Li, Ca or Sr), and optical properties of white LEDs using a GaN-based blue LED and (oxy)nitride phosphors. The phosphors show high conversion efficiency of blue light, suitable emission colours and small thermal quenching. The bichromatic white LEDs exhibit high luminous efficacy (∼55 lm W -1 ) and the multi-phosphor converted white LEDs show high colour rendering index (Ra 82-95). The results indicate that (oxy)nitride phosphors demonstrate their superior suitability to use as down-conversion luminescent materials in white LEDs

  6. Skeletal Muscle Magnetic Resonance Imaging of the Lower Limbs in Late-onset Lipid Storage Myopathy with Electron Transfer Flavoprotein Dehydrogenase Gene Mutations

    Institute of Scientific and Technical Information of China (English)

    Xin-Yi Liu; Ming Jin; Zhi-Qiang Wang; Dan-Ni Wang; Jun-Jie He; Min-Ting Lin; Hong-Xia Fu

    2016-01-01

    Background:Lipid storage myopathy (LSM) is a genetically heterogeneous group with variable clinical phenotypes.Late-onset multiple acyl-coenzyme A dehydrogenation deficiency (MADD) is a rather common form of LSM in China.Diagnosis and clinical management of it remain challenging,especially without robust muscle biopsy result and genetic detection.As the noninvasion and convenience,muscle magnetic resonance imaging (MRI) is a helpful assistant,diagnostic tool for neuromuscular disorders.However,the disease-specific MRI patterns of muscle involved and its diagnostic value in late-onset MADD have not been systematic analyzed.Methods:We assessed the MRI pattern and fat infiltration degree of the lower limb muscles in 28 late-onset MADD patients,combined with detailed clinical features and gene spectrum.Fat infiltration degree of the thigh muscle was scored while that ofgluteus was described as obvious or not.Associated muscular atrophy was defined as obvious muscle bulk reduction.Results:The mean scores were significantly different among the anterior,medial,and posterior thigh muscle groups.The mean of fat infiltration scores on posterior thigh muscle group was significantly higher than either anterior or medial thigh muscle group (P < 0.001).Moreover,the mean score on medial thigh muscle group was significantly higher than that of anterior thigh muscle group (P < 0.01).About half of the patients displayed fat infiltration and atrophy in gluteus muscles.Of 28 patients,12 exhibited atrophy in medial and/or posterior thigh muscle groups,especially in posterior thigh muscle group.Muscle edema pattern was not found in all the patients.Conclusions:Late-onset MADD patients show a typical muscular imaging pattern of fat infiltration and atrophy on anterior,posterior,and medial thigh muscle groups,with major involvement of posterior thigh muscle group and gluteus muscles and a sparing involvement of anterior thigh compartment.Our findings also suggest that muscle MRI of

  7. Fabrication and characterization of Gd2O2SO4:Tb3+ phosphors by sol-gel method

    Science.gov (United States)

    Aritman, I.; Yildirim, S.; Kisa, A.; Guleryuz, L. F.; Yurddaskal, M.; Dikici, T.; Celik, E.

    2017-02-01

    The objective of the innovative approaches of the scintillation materials to be used in the digital portal imaging systems in the radiotherapy applications is to research the GOS material production that has been activated with the rare earth elements (RE), to produce the scintillation detectors that have a rapid imaging process with a lesser radiation and higher image quality from these materials and to apply the radiographic imaging systems. The GOS: Tb3+ showed high emission peak and high x-ray absorption properties which have been determined for application to mammography and dental radiography. In this study, Gd2O2SO4:Tb3+ phosphors were fabricated by the sol-gel method that is a unique technique and not previously applied. Besides, the structural characterization of GOS: Tb3+ has been investigated. The strongest emission peak located at 549 nm under 312 nm UV light excitation was appeared on the GOS: Tb3+ phosphor particles. The characterization processing optimized by using FTIR, DTA-TG, XRD, XPS, SEM and the luminescence spectroscopy.

  8. Phosphors for solid-state lighting: New systems, deeper understanding

    Science.gov (United States)

    Denault, Kristin Ashley

    We explore the structure-composition-property relationships in phosphor materials using a multitude of structural and optical characterization methods including high resolution synchrotron X-ray and neutron powder diffraction and total scattering, low-temperature heat capacity, temperature- and time-resolved photoluminescence, and density functional theory calculations. We describe the development of several new phosphor compositions and provide an in-depth description of the structural and optical properties. We show structural origins of improved thermal performance of photoluminescence and methods for determining structural rigidity in phosphor hosts that may lead to improved luminescent properties. New white light generation strategies are also explored. We begin by presenting the development of a green-yellow emitting oxyfluoride solid-solution phosphor Sr2Ba(AlO4F)1- x(SiO5)x:Ce3+. An examination of the host lattice, and the local structure around the Ce3+ activator ions points to how chemical substitutions play a crucial role in tuning the optical properties of the phosphor. The emission wavelength can be tuned from green to yellow by tuning the composition, x. Photoluminescent quantum yield is determined to be 70+/-5% for some of the examples in the series with excellent thermal properties. Phosphor-converted LED devices are fabricated using an InGaN LED and are shown to exhibit high color rendering white light. Next, we identify two new phosphor solid-solution systems, (Ba1- xSrx)9 Sc2Si6O24:Ce3+,Li+ and Ba9(Y1-ySc y)2Si6O24:Ce3+. The substitution of Sr for Ba in (Ba1-xSrx ) 9Sc2Si6O24:Ce 3+,Li + results in a decrease of the alkaline earth-oxygen bond distances at all three crystallographic sites, leading to changes in optical properties. The room temperature photoluminescent measurements show the structure has three excitation peaks corresponding to Ce3+ occupying the three independent alkaline earth sites. The emission of (Ba 1- xSrx) 9Sc2Si 6O24:Ce3

  9. Ionic liquid-assisted hydrothermal synthesis of dendrite-like NaY(MoO{sub 4}){sub 2}:Tb{sup 3+} phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Tian Yue [Department of Physics, Dalian Maritime University, Dalian, Liaoning 116026 (China); College of Life Science, Dalian Nationalities University, Dalian, Liaoning 116600 (China); Chen Baojiu, E-mail: chenmbj@sohu.com [Department of Physics, Dalian Maritime University, Dalian, Liaoning 116026 (China); Tian Bining [Department of Physics, Dalian Maritime University, Dalian, Liaoning 116026 (China); College of Life Science, Dalian Nationalities University, Dalian, Liaoning 116600 (China); Sun Jiashi; Li Xiangping; Zhang Jinsu; Cheng Lihong; Zhong Haiyang; Zhong Hua [Department of Physics, Dalian Maritime University, Dalian, Liaoning 116026 (China); Meng Qingyu [School of Physics and Electronic Engineering, Harbin Normal University, Harbin 150025 (China); Hua Ruinian, E-mail: rnhua@dlnu.edu.cn [College of Life Science, Dalian Nationalities University, Dalian, Liaoning 116600 (China)

    2012-07-01

    Micro-sized NaY(MoO{sub 4}){sub 2}:Tb{sup 3+} phosphors with dendritic morphology was synthesized by a ionic liquid-assisted hydrothermal process. X-ray diffraction (XRD) indicated that the as-prepared product is pure tetragonal phase of NaY(MoO{sub 4}){sub 2}. Field emission scanning electron microscopy (FE-SEM) images showed that the as-prepared NaY(MoO{sub 4}){sub 2}:Tb{sup 3+} phosphors have dendritic morphology. The photoluminescent (PL) spectra displayed that the as-prepared NaY(MoO{sub 4}){sub 2}:Tb{sup 3+} phosphors show a stronger green emission with main emission wavelength 545 nm corresponding to the {sup 5}D{sub 4}{yields}{sup 7}F{sub 5} transition of Tb{sup 3+} ion, and the optimal Tb{sup 3+} doping concentration for obtaining maximum emission intensity was confirmed to be 10 mol%. Based on Van Uitert's and Dexter's models the electric dipole-dipole (D-D) interaction was confirmed to be responsible for the concentration quenching of {sup 5}D{sub 4} fluorescence of Tb{sup 3+} in the NaY(MoO{sub 4}){sub 2}:Tb{sup 3+} phosphors. The intrinsic radiative transition lifetime of {sup 5}D{sub 4} level is found to be 0.703 ms.

  10. Potential of multispectral imaging technology for rapid and non-destructive determination of the microbiological quality of beef filets during aerobic storage

    DEFF Research Database (Denmark)

    Panagou, Efstathios Z.; Papadopoulou, Olga; Carstensen, Jens Michael

    2014-01-01

    counts, namely Class 1 (TVC7.0log10CFU/g). Furthermore, PLS regression models were developed to provide quantitative estimations of microbial counts during meat storage. In both cases model validation was implemented with independent experiments at intermediate storage temperatures (2 and 10°C) using....... thermosphacta, and TVC, respectively. The results indicated that multispectral vision technology has significant potential as a rapid and non-destructive technique in assessing the microbiological quality of beef fillets....

  11. Kinetic study of ion exchange in phosphoric acid chelating resin

    International Nuclear Information System (INIS)

    Brikci-Nigassa, Mounir; Hamouche, Hafida

    1995-11-01

    Uranium may be recovered as a by product of wet phosphoric acid using a method based on specific ion exchange resins. These resins called chelates contain amino-phosphonic functional groups. The resin studied in this work is a purolite S-940; uranium may be loaded on this resin from 30% P2O5 phosphoric acid in its reduced state. The influence of different parameters on the successive steps of the process have been studied in batch experiments: uranium reduction, loading and oxydation. Uranium may be eluted with ammonium carbonate and the resin regeneration may be done with hydrochloric acid.Ferric ions reduce the effective resin capacity considerably and inert fixation conditions are proposed to enhance uranium loading

  12. Polycrystalline Silicon Gettered by Porous Silicon and Heavy Phosphorous Diffusion

    Institute of Scientific and Technical Information of China (English)

    LIU Zuming(刘祖明); Souleymane K Traore; ZHANG Zhongwen(张忠文); LUO Yi(罗毅)

    2004-01-01

    The biggest barrier for photovoltaic (PV) utilization is its high cost, so the key for scale PV utilization is to further decrease the cost of solar cells. One way to improve the efficiency, and therefore lower the cost, is to increase the minority carrier lifetime by controlling the material defects. The main defects in grain boundaries of polycrystalline silicon gettered by porous silicon and heavy phosphorous diffusion have been studied. The porous silicon was formed on the two surfaces of wafers by chemical etching. Phosphorous was then diffused into the wafers at high temperature (900℃). After the porous silicon and diffusion layers were removed, the minority carrier lifetime was measured by photo-conductor decay. The results show that the lifetime's minority carriers are increased greatly after such treatment.

  13. Modeling Phosphorous Losses from Seasonal Manure Application Schemes

    Science.gov (United States)

    Menzies, E.; Walter, M. T.

    2015-12-01

    Excess nutrient loading, especially nitrogen and phosphorus, to surface waters is a common and significant problem throughout the United States. While pollution remediation efforts are continuously improving, the most effective treatment remains to limit the source. Appropriate timing of fertilizer application to reduce nutrient losses is currently a hotly debated topic in the Northeastern United States; winter spreading of manure is under special scrutiny. We plan to evaluate the loss of phosphorous to surface waters from agricultural systems under varying seasonal fertilization schemes in an effort to determine the impacts of fertilizers applied throughout the year. The Cayuga Lake basin, located in the Finger Lakes region of New York State, is a watershed dominated by agriculture where a wide array of land management strategies can be found. The evaluation will be conducted on the Fall Creek Watershed, a large sub basin in the Cayuga Lake Watershed. The Fall Creek Watershed covers approximately 33,000 ha in central New York State with approximately 50% of this land being used for agriculture. We plan to use the Soil and Water Assessment Tool (SWAT) to model a number of seasonal fertilization regimes such as summer only spreading and year round spreading (including winter applications), as well as others. We will use the model to quantify the phosphorous load to surface waters from these different fertilization schemes and determine the impacts of manure applied at different times throughout the year. More detailed knowledge about how seasonal fertilization schemes impact phosphorous losses will provide more information to stakeholders concerning the impacts of agriculture on surface water quality. Our results will help farmers and extensionists make more informed decisions about appropriate timing of manure application for reduced phosphorous losses and surface water degradation as well as aid law makers in improving policy surrounding manure application.

  14. Thermoluminescent phosphors for ultraviolet radiation dosimetry - a review

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    2001-01-01

    Intrinsic TL response of CaSO 4 , CaF 2 , Al 2 O 3 (Si,Ti), Mg 2 SiO 4 : Tb and lamp phosphors to ultraviolet radiation is reviewed. Taking into consideration the characteristics such as afterglow at RT, rate/flux dependence, linearity of response, useful range, spectral dependence and effect of sequential/tandem UV exposures CaF 2 :Eu 2+ is an ideal TL dosemeter for UV radiation dosimetry. (author)

  15. Light Converting Inorganic Phosphors for White Light-Emitting Diodes

    OpenAIRE

    Chen, Lei; Lin, Chun-Che; Yeh, Chiao-Wen; Liu, Ru-Shi

    2010-01-01

    White light-emitting diodes (WLEDs) have matched the emission efficiency of florescent lights and will rapidly spread as light source for homes and offices in the next 5 to 10 years. WLEDs provide a light element having a semiconductor light emitting layer (blue or near-ultraviolet (nUV) LEDs) and photoluminescence phosphors. These solid-state LED lamps, rather than organic light emitting diode (OLED) or polymer light-emitting diode (PLED), have a number of advantages over conventional incand...

  16. Determination of vanadium in Syrian commercial and raffinate phosphoric acid

    International Nuclear Information System (INIS)

    Al-Merey, R.

    2002-04-01

    This study presents two methods for vanadium determination in Syrian commercial phosphoric acid. The vanadium (V) in the oxidized commercial phosphoric acid by ammonium persulfate solution is extracted from 5-M hydrochloride acid medium using N-benzoyl-N-phenyl hydroxyl amine (BPHA) in chloroform as an extracting solution. The first method, the extract vanadium as VOL 2 Cl is changed to V 2 O 3 L 4 complex by the addition of benzimidazole in 1-butanol to the violet organic layer. The absorbance is then measured at 440 nm (the molar absorptivity was found to be 3865 M -1 cm -1 ), where Beer law is applicable up to 36-μg ml -1 . the accuracy, precision and detection limit were found to be 3.7%, 77 ppb and 37 ppb, respectively. the second method, the organic layer is heated to evaporate chloroform, the residue is digested using 20% ammonium persulfate and 2-M sulfuric acid solutions. The vanadium concentration is measured spectrophotometrically by oxidizing gallic acid with persulfate (S 2 O 8 2- ) anion in phosphoric acid medium, where the vanadium (V) acts as a catalyst in the oxidation reaction. This method has a high sensitivity (∼10 -12 ) with accuracy and precision 5% and 0.621 ppb, respectively. Also Beer law at λ m ax=415 nm (ε=∼2 x 10 6 M -1 ) is applicable in the range 2.58-33.3 ppb. (author)

  17. Simple preparation of LiF:Mg,Ti phosphor

    International Nuclear Information System (INIS)

    Moharil, S.V.; Shahare, D.I.; Upaded, S.V.; Deshmukh, B.T.

    1993-01-01

    LiF-TLD 100 is a low-impedance (Z eff = 8.2) tissue equivalent material which is widely used in thermoluminescence (TL) dosimetry of ionizing radiations and personnel monitoring. Mg and Ti have been found to be the major impurities which impart the Tl characteristics. Recipes for the preparation of this phosphor, have not been found to be satisfactory for routine manufacture; there have always been problems associated with reproducibility and even with batch homogeneity. One of the reasons for this is that most procedures start either from readily available LiF or by melting the synthesized LiF, or both. The background impurities in the starting LiF powder can mask the intentional impurities, particularly Ti which has to be doped in rather small concentrations (10 p.p.m.). Melting LiF can again be tricky, as the LiF melt is volatile and highly corrosive. In this letter we report the preparation of LiF: Mg, Ti. The impurities were incorporated during the synthesis of LiF. The phosphor was prepared by heat treatments in ambient air without melting the compound. The characteristics of the prepared phosphors were studied and compared with those of LiF-TLD 100. (author)

  18. Instense red phosphors for UV light emitting diode devices.

    Science.gov (United States)

    Cao, Fa-Bin; Tian, Yan-Wen; Chen, Yong-Jie; Xiao, Lin-Jiu; Liu, Yun-Yi

    2010-03-01

    Ca(x)Sr1-x-1.5y-0.5zMoO4:yEu3+ zNa+ red phosphors were prepared by solid-state reaction using Na+ as charge supply for LEDs (light emitting diodes). The content of charge compensator, Ca2+ concentration, synthesis temperature, reaction time, and Eu3+ concentration were the keys to improving the properties of luminescence and crystal structure of red phosphors. The photoluminescence spectra shows the red phosphors are effectively excited at 616 nm by 311 nm, 395 nm, and 465 nm light. The wavelengths of 395 and 465 nm nicely match the widely applied emission wavelengths of ultraviolet or blue LED chips. Its chromaticity coordinates (CIE) are calculated to be x = 0.65, y = 0.32. Bright red light can be observed by the naked eye from the LED-based Ca0.60Sr0.25MoO4:0.08Eu3+ 0.06Na+.

  19. Technology of uranium recovery from wet-process phosphoric acid

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Katsutoshi [Saga Univ. (Japan). Faculty of Science and Engineering; Nakashio, Fumiyuki

    1982-12-01

    Rock phosphate contains from 0.005 to 0.02 wt.% of uranium. Though the content is a mere 5 to 10 % of that in uranium ore, the total recovery of uranium is significant since it is used for fertilizer manufacture in a large quantity. Wet-process phosphoric acid is produced by the reaction of rock phosphate with sulfuric acid. The recovery of uranium from this phosphoric acid is mostly by solvent extraction at present. According to U/sup 4 +/ or UO/sub 2//sup 2 +/ as the form of its existence, the technique of solvent extraction differs. The following matters are described: processing of rock phosphate; recovery techniques including the extraction by OPPA-octyl pyrophosphoric acid for U/sup 4 +/, and by mixed DEHPA-Di-(2)-ethylhexyl phosphoric acid and TOPO-tryoctyl phosphine oxide for UO/sub 2//sup 2 +/, and by OPAP-octylphenyl acid phosphate for U/sup 4 +/; the recent progress of the technology as seen in patents.

  20. An orange emitting phosphor Lu2−xCaMg2Si2.9Ti0.1O12:xCe with pure garnet phase for warm white LEDs

    International Nuclear Information System (INIS)

    Chu, Yaoqing; Zhang, Qinghong; Xu, Jiayue; Li, Yaogang; Wang, Hongzhi

    2015-01-01

    A new silicate garnet phosphor, Lu 2−x CaMg 2 Si 2.9 Ti 0.1 O 12 :xCe was synthesized by a high temperature solid-state reaction under reductive atmosphere. X-ray diffraction (XRD) showed that the powder was pure garnet phase. The emission and excitation spectrum indicated that the Lu 2−x CaMg 2 Si 2.9 Ti 0.1 O 12 :xCe phosphors could absorb blue light in the spectral range of 400–550 nm efficiently and exhibit bright yellow–orange emission in the range of 520–750 nm. With the increase of Ce 3+ concentration, the emission band of Ce 3+ showed a red shift. Interestingly, the concentration quenching occurred when the Ce 3+ concentration exceeded 4 mol%. The temperature-dependent luminescent properties of the phosphors were discussed and the Lu 1.96 CaMg 2 Si 2.9 Ti 0.1 O 12 :0.04Ce phosphors showed good performances in color temperature (2430 K) and potential applications for warm white LEDs. - Graphical Abstract: This image shows that the phosphor of Lu 1.96 CaMg 2 Si 2.9 Ti 0.1 O 12 :0.04Ce can generate a uniform yellow tint under natural light illumination and emit orange–red light when excited by blue light. With a fixed 467 nm emission light, warm white light can be produced by this phosphor, which indicates that the phosphor is potentially applicable in warm white light emitting diodes based on GaN chips. - Highlights: • A new silicate garnet phosphor was synthesized by solid-state method. • Secondary phases can be avoided when a small amount of Si 4+ were replaced by Ti 4+ . • A broad emission band of Ce 3+ in the phosphors was described. • The phosphors are potentially applicable in warm white light emitting diodes

  1. Energy Storage

    CSIR Research Space (South Africa)

    Bladergroen, B

    2015-10-01

    Full Text Available In commercial arena, the most recent developments in EES are in electrochemical storage, singling out Li-ion batteries and Vanadium Redox flow batteries, while power-to-gas/-fuels (electrolysis of water into hydrogen and subsequent methanisation...

  2. Liver Storage

    African Journals Online (AJOL)

    1971-10-23

    Oct 23, 1971 ... The need for whole-organ preservation has become in- cre.asingly important ... ideally fulfil the same purpose as the circulation of blood through the body, ... Hepatic hypothermia produced by the introduction of cold electrolyte ... Recently, we reported successful hypothermic immersion storage for up to 8 ...

  3. Dry storage

    International Nuclear Information System (INIS)

    Arnott, Don.

    1985-01-01

    The environmental movement has consistently argued against disposal of nuclear waste. Reasons include its irretrievability in the event of leakage, the implication that reprocessing will continue and the legitimacy attached to an expanding nuclear programme. But there is an alternative. The author here sets out the background and a possible future direction of a campaign based on a call for dry storage. (author)

  4. The bright side of defects: Chemistry and physics of persistent and storage phosphors

    Energy Technology Data Exchange (ETDEWEB)

    Kulesza, D.; Wiatrowska, A.; Trojan-Piegza, J. [Faculty of Chemistry, University of Wroclaw 14F. Joliot-Curie Street, 50-383 Wroclaw (Poland); Felbeck, T.; Geduhn, R.; Motzek, P. [Department of Chemical Engineering, University of Applied Sciences Muenster/Steinfurt Campus, 39 Stegerwaldstrasse, D-48565 Steinfurt (Germany); Zych, E., E-mail: eugeniusz.zych@chem.uni.wroc.pl [Faculty of Chemistry, University of Wroclaw 14F. Joliot-Curie Street, 50-383 Wroclaw (Poland); Wroclaw Research Centre EIT 147/149 Stablowicka Street, 54-066 Wroclaw (Poland); Kynast, U. [Department of Chemical Engineering, University of Applied Sciences Muenster/Steinfurt Campus, 39 Stegerwaldstrasse, D-48565 Steinfurt (Germany)

    2013-01-15

    Ceramic specimens of singly doped Lu{sub 2}O{sub 3}:Tb, and doubly activated Lu{sub 2}O{sub 3}:Tb,Ca, Lu{sub 2}O{sub 3}:Tb,Hf and Lu{sub 2}O{sub 3}:Pr,Hf were prepared and their thermoluminescent properties were investigated. After irradiation with X-rays or deep-UV photons the singly doped Lu{sub 2}O{sub 3}:Tb was found to produce a glow curve with a few thermoluminescent bands spread across the temperature range of 50-450 Degree-Sign C. (Tb,Ca) co-doped material produced basically one strong thermoluminescent band peaking at around 120 Degree-Sign C and thus was able to produce persistent luminescence lasting about 10 h, as visible to the human eye. In the (Tb,Hf) co-doped ceramics the thermoluminescence at around 100 Degree-Sign C was seen as a vestige only and was responsible for persistent emission lasting merely a few minutes. Instead, a strong thermoluminescence glow band at around 250 Degree-Sign C appeared. Its intensity faded by about 10% after 6 hours in the dark. Lu{sub 2}O{sub 3}:Pr,Hf co-doped ceramics also showed intense thermoluminescence with the main components at around 200 Degree-Sign C and 270 Degree-Sign C. The latter was found not to fade in time, while intensity of the former dropped by about 7-8% after 6 h. All these effects were observed in ceramics processed at temperatures as high as 1700 Degree-Sign C. It is proposed that high temperature of processing is necessary as only then clustering of individual defects occurs and the energy released upon heating can diffuse towards the nearby located emitting center efficiently. - Highlights: Black-Right-Pointing-Pointer Thermoluminescence of Lu{sub 2}O{sub 3}:Tb,Ca, Lu{sub 2}O{sub 3}:Tb,Hf and Lu{sub 2}O{sub 3}:Pr,Hf is presented. Black-Right-Pointing-Pointer Efficient energy storing by the compositions is proved. Black-Right-Pointing-Pointer Influence of the co-dopants on traps characteristics are showed.

  5. Spectral properties of Dy3+ doped ZnAl2O4 phosphor

    Science.gov (United States)

    Prakash, Ram; Kumar, Sandeep; Mahajan, Rubby; Khajuria, Pooja; Kumar, Vinay; Choudhary, R. J.; Phase, D. M.

    2018-05-01

    Herein, Dy3+ doped ZnAl2O4 phosphor was synthesized by the solution combustion method. The synthesized phosphor was characterized by X-ray diffraction (XRD), photoluminescence (PL) spectroscopy, UV-Vis spectroscopy and X-ray photoelectron spectroscopy (XPS). The phase purity of the phosphor was confirmed by the XRD studies that showed cubic symmetry of the synthesized phosphor. Under UV excitation (388 nm) the PL emission spectrum of the phosphor shows characteristic transition from the Dy3+ ion. A band gap of 5.2 eV was estimated from the diffused reflectance spectroscopy. The surface properties of the phosphor were studied using the X-ray photoelectron spectroscopy.

  6. Neutron scintillator using Ga-doped ZnO phosphor with high detection efficiency

    International Nuclear Information System (INIS)

    Koyama, Shin; Kinoshita, Atsushi; Fujiwara, Akihiko; Kobayashi, Haruki; Takei, Yoshinori; Nanto, Hidehito; Katagiri, Masaki

    2009-01-01

    Zinc Oxide (ZnO) family phosphors as phosphor for neutron detector have prepared using Spark Plasma Sintering (SPS) method. The optical properties of ZnO phosphor prepared are investigated. The following results were obtained. Two dominant photoluminescence (PL) emission peaks at 395 nm and 495 nm were observed. The lifetime of the PL emission peak at 395 nm (UV emission band) is about 20 ns, which is suitable for neutron detection. The Ga (30 mol%)-doped ZnO phosphor exhibited an intense UV emission band without the visible emission band. The Ga-doped ZnO phosphor can be prepared at the atmospheric pressure of about 8 Pa using SPS method. It was found that the PL intensity of UV emission band is increased with improving the crystallinity of the ZnO phosphor. (author)

  7. Critical issues in enhancing brightness in thin film phosphors for flat-panel display applications

    International Nuclear Information System (INIS)

    Singh, R.K.; Chen, Z.; Kumar, D.; Cho, K.; Ollinger, M.

    2002-01-01

    Thin film phosphors have potential applications in field emission flat-panel displays. However, they are limited by the lower cathodoluminescent brightness in comparison to phosphor powders. In this paper, we have investigated the critical parameters that need to be optimized to increase the brightness of phosphor thin films. Specifically, we studied the role of surface roughness and optical properties of the substrate on the brightness of the phosphor films. Thin Y 2 O 3 :Eu phosphor films were deposited on various substrates (lanthanum aluminate, quartz, sapphire, and silicon) with thicknesses varying from 50 to 500 nm. A model that accounts for diffuse and specular or scattering effects has been developed to understand the effects of the microstructure on the emission characteristics of the cathodoluminescent films. The results from the model show that both the optical properties of the substrate and the surface roughness of the films play a critical role in controlling the brightness of laser deposited phosphor films

  8. Storage Rings

    International Nuclear Information System (INIS)

    Fischer, W.

    2010-01-01

    Storage rings are circular machines that store particle beams at a constant energy. Beams are stored in rings without acceleration for a number of reasons (Tab. 1). Storage rings are used in high-energy, nuclear, atomic, and molecular physics, as well as for experiments in chemistry, material and life sciences. Parameters for storage rings such as particle species, energy, beam intensity, beam size, and store time vary widely depending on the application. The beam must be injected into a storage ring but may not be extracted (Fig. 1). Accelerator rings such as synchrotrons are used as storage rings before and after acceleration. Particles stored in rings include electrons and positrons; muons; protons and anti-protons; neutrons; light and heavy, positive and negative, atomic ions of various charge states; molecular and cluster ions, and neutral polar molecules. Spin polarized beams of electrons, positrons, and protons were stored. The kinetic energy of the stored particles ranges from 10 -6 eV to 3.5 x 10 12 eV (LHC, 7 x 10 12 eV planned), the number of stored particles from one (ESR) to 1015 (ISR). To store beam in rings requires bending (dipoles) and transverse focusing (quadrupoles). Higher order multipoles are used to correct chromatic aberrations, to suppress instabilities, and to compensate for nonlinear field errors of dipoles and quadrupoles. Magnetic multipole functions can be combined in magnets. Beams are stored bunched with radio frequency systems, and unbunched. The magnetic lattice and radio frequency system are designed to ensure the stability of transverse and longitudinal motion. New technologies allow for better storage rings. With strong focusing the beam pipe dimensions became much smaller than previously possible. For a given circumference superconducting magnets make higher energies possible, and superconducting radio frequency systems allow for efficient replenishment of synchrotron radiation losses of large current electron or positron beams

  9. Luminescent characteristics of UV excited Sr{sub 0.5}Ca{sub 0.5}TiO{sub 3}: Pr{sup 3+} reddish-orange phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Vidyadharan, Viji; Mohan P, Remya; Joseph, Cyriac; Unnikrishnan, N.V.; Biju, P.R., E-mail: prb.mgu@gmail.com

    2016-02-15

    Pr{sup 3+} doped Sr{sub 0.5}Ca{sub 0.5}TiO{sub 3} phosphors were synthesised by solid state reaction process. The structure, surface morphology and photoluminescence of the prepared phosphors were analysed using XRD, SEM and photoluminescence spectroscopy respectively. The XRD pattern confirmed orthorhombic perovskite structure of the Sr{sub 0.5}Ca{sub 0.5}TiO{sub 3}: x Pr{sup 3+} phosphor. Agglomeration of particles with irregular shapes is observed from the SEM images. The emission spectra of Sr{sub 0.5}Ca{sub 0.5}TiO{sub 3}: x Pr{sup 3+} phosphor shows the samples can be effectively excited with UV light at 336 nm and exhibit a strong reddish-orange emission at 611 nm. Concentration dependence of emission intensity shows concentration quenching effect on increasing Pr{sup 3+} concentration after x = 0.1 because of dipole–dipole interaction. Using Blasse's formula, critical distance for energy transfer was calculated. The CIE co-ordinates, CCT, colour purity and luminescence decay of the prepared phosphors were also calculated. These results offer the prepared phosphor as a suitable candidate for various photonic applications. - Highlights: • Sr{sub 0.5}Ca{sub 0.5}TiO{sub 3}: x Pr{sup 3+} perovskite structured phosphors were synthesized. • Under UV excitation, the PL spectra show strong reddish-orange emission. • The emission from {sup 3}P{sub J} levels of Pr{sup 3+} were absent due to the presence of IVCT band. • Concentration quenching due to dipole–dipole interaction was observed. • For x = 0.1, sample shows a maximum emission intensity with 91.7% colour purity.

  10. Calculated energy dependence of CaSO4:Dy TL phosphor and phosphor embedded Teflon for X and gamma rays

    International Nuclear Information System (INIS)

    Chang, J.-K.; Nam, Y.-M.; Kim, J.-L.; Chang, S.-Y.; Kim, B.-H.

    2001-01-01

    The energy dependence of a CaSO 4 :Dy TL phosphor for 21 monoenergetic photons of energy ranging from 0.01 to 3 MeV was calculated by using MCNP4A code. The calculation results show good agreement with those of other authors within ± 5% relative error. Calculations and experiments are also performed to determine the energy dependence of CaSO 4 : Dy phosphor with Dy concentrations from 0.01 to 1.5 mol %, and with the compositions of TL-Teflon from 10 to 90 wt %. The calculated energy responses show good agreement with the experiment results within ± 20% relative error except for a concentration lower than 0.1 mol % Dy and the low energy regions of M30 (Eave.=20 keV) and M60 (Eave.=34 keV). For the TL-Teflon mixture, the energy dependence shows an decreasing trend with the increase of Teflon concentration in MCNP calculation but shows no dependence for TL-Teflon mixture proportions in experiment. These differences are due to the non-homogeneous distribution of Dy concentration and the effect of large grain size in the phosphors. The energy dependence of the 30 wt/o CaSO 4 (0.1 mol%;Dy) and 70 wt/o Teflon that is placed behind the filters of plastic, aluminum, copper, tin and lead with a thickness from 0.1 to 2 mm were calculated, respectively

  11. Synthesis and complex forming property of phosphor acid derivatives

    International Nuclear Information System (INIS)

    Babaev, B.N.

    2004-01-01

    Full text:With the aim to get new effective and selective extra gents of noble and non-ferrous metals from acid solution and industrial sewage, research of the dependence of 'structure effectiveness' the various phosphor acid derivatives with logical changeable structure (thio phosphor acids, derivatives of dialkoxythiophosphor, O-alkyl-methylphosphon, alkylphenylphosphon, diphenylphosphine acids also 4 methyl-1,3,2 dioxaphosphorinane) which contain different functional groups, the remains of heterocyclic amines and alkaloids, new derivatives of some analytical reagents were synthesized. The structure of synthesized compounds is approved by the results of IR-, PMR-, mass-spectrum analyze. Researching mass-spectrum decay of synthesized phosphor acid derivatives we defined that differing from O-dihexyl-S-propargyl-benzylthio phosphat, mass spectrum decay of O-dialkyl-S-(piperdynobutin-2-il)thio phosphat is characterized by the appearing [M-H] + ions and during the decay ions with high intensiveness are formed. Fragmentation of M + O-alkyl-O-(aminoalkyl)phenylphosphonate proceeds in various directions and characterized with the great number of phosphor containing ions, the possession of the second phenyl radical in the molecule of diphenylphosphon acid derivatives changes the fragmentation of molecular ion of diphenylphosphon acid derivatives. The process of extraction of noble (Au, Ag, Pt, Pd, Os) metals from hydrochloric-sulphur-nitrogen acid medium was analyzed by radioactive indicator's method. It was noticed that structure, strength, conformation of compounds, the temperature, of acid medium (0,1-10 M) and the nature of acids (HCL, H 2 SO 4 , HNO 3 ) could have strong influence to the effectiveness of metal extraction. During the research of metals extraction from pure solutions we can see the followings: 1) There are such substances, which can be used as effective group reagent towards the Au, Ag and Pd. 2) Derivatives with acetylene extract ions of gold from

  12. Optical and x-ray imaging of electron beams using synchrotron emission

    International Nuclear Information System (INIS)

    Wilke, M.

    1995-01-01

    In the case of very low emittance electron and positron storage ring beams, it is impossible to make intrusive measurements of beam properties without increasing the emittance and possibly disrupting the beam. In cases where electron or positron beams have high average power densities (such as free electron laser linacs), intrusive probes such as wires and optical transition radiation screens or Cherenkov emitting screens can be easily damaged or destroyed. The optical and x-ray emissions from the bends in the storage rings and often from linac bending magnets can be used to image the beam profile to obtain emittance information about the beam. The techniques, advantages and limitations of using both optical and x-ray synchrotron emission to measure beam properties are discussed and the possibility of single bunch imaging is considered. The properties of suitable imagers and converters such as phosphors are described. Examples of previous, existing and planned applications are given where available, including a pinhole imaging system currently being designed for the Advanced Photon Source at Argonne National Laboratory

  13. Optical and x-ray imaging of electron beams using synchrotron emission

    International Nuclear Information System (INIS)

    Wilke, M.D.

    1994-01-01

    In the case of very low eniittance electron and positron storage ring beams, it is impossible to make intrusive measurements of beam properties without increasing the emittance and possibly disrupting the beam. In cases where electron or positron beams have high average power densities (such as free electron laser linacs), intrusive probes such as wires and optical transition radiation screens or Cherenkov emitting screens can be easily damaged or destroyed. The optical and x-ray emissions from the bends in the storage rings and often from linac bending magnets can be used to image the beam profile to obtain emittance information about the beam. The techniques, advantages and limitations of using both optical and x-ray synchrotron emission to measure beam properties are discussed and the possibility of single bunch imaging is considered. The properties of suitable imagers and converters such as phosphors are described. Examples of previous, existing and planned applications are given where available, including a pinhole imaging system currently being designed for the Advanced Photon Source at Argonne National Laboratory

  14. Influence of water storage on fatigue strength of self-etch adhesives.

    Science.gov (United States)

    Takamizawa, Toshiki; Barkmeier, Wayne W; Tsujimoto, Akimasa; Scheidel, Donal D; Watanabe, Hidehiko; Erickson, Robert L; Latta, Mark A; Miyazaki, Masashi

    2015-12-01

    The purpose of this study was to determine enamel and dentin bond durability after long-term water storage using self-etch adhesives. Two single step self-etch adhesives (SU, Scotchbond Universal and GB, G-ӕnial Bond) and a two-step self-etch adhesive (OX, OptiBond XTR) were used. The shear bond strength (SBS) and shear fatigue strength (FS) of the enamel and dentin were obtained with and without phosphoric acid pre-etching prior to application of the adhesives. The specimens were stored in distilled water at 37 °C for 24 h, 6 months, and one year. A staircase method was used to determine the FS using a frequency of 10 Hz for 50,000 cycles or until failure occurred. The SBS and FS of enamel bonds were significantly higher with pre-etching, when compared to no pre-etching for the same water storage period. The FS of dentin bonds with pre-etching tended to decrease relative to no pre-etching at the same storage period. For the one year storage period, SU and GB with pre-etching showed significantly lower FS values than the groups without pre-etching. The influence of water storage on FS of the self-etch adhesives was dependent on the adhesive material, storage period and phosphoric acid pre-etching of the bonding site. Phosphoric acid pre-etching of enamel improves the effectiveness of self-etch adhesive systems. Inadvertent contact of phosphoric acid on dentin appears to reduce the ability of self-etch adhesives to effectively bond resin composite materials. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Study of photoluminescence and thermoluminescence properties of BaAl2O4 (Eu2+, Dy3+) phosphor synthesized by solution combustion method

    Science.gov (United States)

    Pathak, Pushpraj; Kurchania, Rajnish

    2016-10-01

    Eu and Dy co-doped barium aluminate phosphor was successfully synthesized by combustion method using urea as a fuel. Phase formation was confirmed by powder X-ray diffraction (PXRD) analysis. The calculated average crystallite size was found to be ~34.62 nm. Scanning electron microscopy (SEM) images acquired at different (low and high) magnifications reveal that the crystallites have no uniform shape and size. This was due to the non-uniform distribution of temperature and mass flow in the combustion technique. Fourier Transform Infra-red (FTIR) spectrum was recorded to confirm the phase formation and also to identify any impurity if present in the prepared phosphor. Photoluminescence (PL) measurement was carried out to investigate the incorporation of dopant into the host lattice. Thermoluminescence (TL) behaviour of synthesized phosphor was studied after the irradiation with Cobalt-60 gamma rays (Eavg=1.25 MeV) as well as 6 and 16 MV (Mega Voltage) X-ray photons, at various dose levels. The glow curves of irradiated samples exhibit only one peak at 115 °C at each dose level. With the increases of radiation dose an increase in total intensity has been observed. No appreciable shift in peak positions has been observed. Trapping parameters were evaluated to understand the characteristics of prepared phosphor. A simple glow peak with relatively high intensity is one of the important factors, which make this phosphor useful for monitoring the ionizing radiations in nuclear industries, gamma irradiators, high energy accelerators, nuclear reactors etc. where medium and high level of exposure is involved. It could also be applicable for accidental and retrospective dose assessment.

  16. Synthesis and PL study of UV emitting phosphor KCa{sub 4}(BO{sub 3}){sub 3}:Pb{sup 2+}

    Energy Technology Data Exchange (ETDEWEB)

    Gawande, A.B., E-mail: gawandeab@gmail.com [Department of Physics, SGB Amravati University, Amravati, Maharashtra (India); Sonekar, R.P., E-mail: sonekar_rp@yahoo.com [Department of Physics, G.S. College, Khamgaon, Buldhana District, Maharashtra (India); Omanwar, S.K. [Department of Physics, SGB Amravati University, Amravati, Maharashtra (India)

    2014-05-01

    Pb{sup 2+} doped KCa{sub 4}(BO{sub 3}){sub 3} materials were prepared by a novel solution combustion synthesis technique which is slight variation of combustion synthesis method. The synthesized materials were characterized by powder XRD and FT-IR. Scanning Electron Microscopy (SEM) observation indicated that the microstructure of the phosphor consisted of irregular grains which get finer and shaped in doped sample as compared to pure. The photoluminescence properties of synthesized materials were investigated using Spectrofluorometer at room temperature. The emission and excitation bands of the synthesized phosphors were observed at 335 nm and 260 nm respectively. The concentration of Pb{sup 2+} for which optimum emission is obtained was found to be 0.005 mol. The critical transfer distance (R{sub 0}) for optimum concentration was determined to be 16.88 Å. The Stokes shift of KCa{sub 4}(BO{sub 3}){sub 3}:Pb{sup 2+} was measured to be 8756 cm{sup −1}. The phosphor could find application in medical and lamp industry. - Highlights: • Inorganic borate phosphor KCa{sub 4}(BO{sub 3}){sub 3}:Pb{sup 2+} has been synthesized by solution combustion synthesis technique. • Structure confirmation of synthesized phosphor done by using powder XRD and FT-IR. • Doping effect on the surface morphology of synthesized material is shown by SEM images. • Stokes shift, optimum concentration and critical transfer distance for optimum concentration in KCa{sub 4}(BO{sub 3}){sub 3}:Pb{sup 2+} have been determined.

  17. Studies on effect of europium concentration on the photoemission of laser ablated Y2O3:Eu based nano-phosphors

    International Nuclear Information System (INIS)

    Nissamudeen, K.M.; Krishnan, Renju R.; Rajan, Geo; Gopchandran, K.G.

    2007-01-01

    Full text: Phosphors are essential materials in display applications. Oxide-based phosphors are likely to emerge as the potential choice for the FED red phosphor. Among those oxide-based phosphors, there has been significant research interest in the development of Y 2 O 3 :Eu thin films as one of the most promising oxide based red phosphor systems. Yttrium oxide mixed with europium exhibit strong UV and cathode-ray-excited luminescence that are useful in lamp and display applications. Dielectric Y 2 O 3 film has recently attracted much attention for its potential application as an electric insulation layer in electroluminescent devices and high-density dynamic random access memory gate dielectrics because of its high band gap (5.8 eV) and large dielectric constant (14 to 18). Another important application of Y 2 O 3 has been in luminescent displays as a host material for rare-earth ions, specifically europium, in order to get emission of red light. In the present study thin films were deposited under a vacuum of 10 -6 mbar on fused amorphous quartz substrates using a Q-switched Nd: YAG laser, 532 nm, pulse width 9 n sec, and repetition frequency of 10 Hz, with sintered Y 2 O 3 pellets having different europium concentration as target material. Attempts were made to understand the effect of europium concentration and annealing process on the photoemission properties of the films. A europium concentration of 8 wt% and an annealing temperature of 1173 K were found to be optimum conditions for maximum photoemission. The dependence of structure and morphology of the films on the photoemission intensity are described with XRD patterns and images obtained from AFM and SEM studies

  18. Synthesis and luminescence characterization of Pr3+ doped Sr1.5Ca0.5SiO4 phosphor

    Science.gov (United States)

    Vidyadharan, Viji; Mani, Kamal P.; Sajna, M. S.; Joseph, Cyriac; Unnikrishnan, N. V.; Biju, P. R.

    2014-12-01

    Luminescence properties of Pr3+ activated Sr1.5Ca0.5SiO4 phosphors synthesized by solid state reaction method are reported in this work. Blue, orange red and red emissions were observed in the Pr3+ doped sample under 444 nm excitation and these emissions are assigned as 3P0 → 3H4, 3P0 → 3H6 and 3P0 → 3F4 transitions. The emission intensity shows a maximum corresponding to the 0.5 wt% Pr3+ ion. The decay analysis was done for 0.05 and 0.5 wt% Pr3+ doped samples for the transition 3P0 → 3H6. The life times of 0.05 and 0.5 wt% Pr3+ doped samples were calculated by fitting to exponential and non-exponential curve respectively, and are found to be 156 and 105 μs respectively. The non-exponential behaviour arises due to the statistical distribution of the distances between the ground state Pr3+ ions and excited state Pr3+ ions, which cause the inhomogeneous energy transfer rate. The XRD spectrum confirmed the triclinic phase of the prepared phosphors. The compositions of the samples were determined by the energy dispersive X-ray spectra. From the SEM images it is observed that the particles are agglomerated and are irregularly shaped. IR absorption bands were assigned to different vibrational modes. The well resolved peaks shown in the absorption spectra are identical to the excitation spectra of the phosphor samples. Pr3+ activated Sr1.5Ca0.5SiO4 phosphors can be efficiently excited with 444 nm irradiation and emit multicolour visible emissions. From the CIE diagram it can be seen that the prepared phosphor samples give yellowish-green emission.

  19. Study of phase transformation processes in steel after phosphor ion implantation and following thermal treatment

    International Nuclear Information System (INIS)

    Zhetbaev, A.K.; Vereshchak, N.F.; Satpaev, K.K.; Dosmagambetov, T.D.; Serikbaeva, Z.T.

    1999-01-01

    In the paper process of phase transformation after phosphor ion implantation in steel-45 and annealing in vacuum at 1000 deg C and irradiation by various doses of phosphor ions with energy 100 keV an accelerator are researched by conversion electron method. The phosphor overall solubility in iron is equal 4.53 %. Implantation dose below 6·10 17 ions/cm 2 allows increase phosphor ions content in implantation region to 35 %. Therefore, iron phosphides (Fe 3 P, Fe 2 P and Fe P) forming are possible. (author)

  20. Recovering of uranium from phosphoric acid produced by the wet process

    International Nuclear Information System (INIS)

    Barreiro, A.J.; Lyon, W.L.; Holleman, R.A.; Randell, C.C.

    1977-01-01

    Process for recovering uranium as from an aqueous solution of phosphoric acid arising from a wet process, with a scrubbing agent essentially composed of a hydrocarbon whose boiling point is situated between 150 0 C and 300 0 C, which reacts with the contaminents formed in the sludge in the phosphoric acid, in an efficient enough quantity to wash the contamination products forming the phosphoric acid sludge, give a sludge phase and a purified phosphoric acid phase, after which the sludge phase is extracted [fr

  1. TL-OSL study of Li{sub 3}PO{sub 4}: Mg, Cu phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Rahangdale, S. R., E-mail: sachin.rahangdale1@gmail.com; Wankhede, S. P. [Department of Physics, K.D.K.College of Engineering, Nagpur (India); Dhabekar, B. S. [RPAD, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Palikundwar, U. A.; Moharil, S. V. [Department of Physics, RTM Nagpur University, Nagpur, 440010 (India)

    2015-08-28

    In the present work, we report the thermoluminescence and optically stimulated luminescence properties of Mg and Cu doped Li{sub 3}PO{sub 4} phosphor. The phosphor was synthesized by precipitation method. The thermoluminescence dosimetric peak temperature for the phosphor varies with concentrations of Mg and Cu. Li{sub 3}PO{sub 4} shows good response to 470nm optical stimulation. The OSL sensitivity of the phosphor is approximately 12 times than that of standard Lithium magnesium phosphate. This study may help to develop this material for the application in real time dosimetry using optically stimulated luminescence.

  2. New Silicate Phosphors for a White LED(Electronic Displays)

    OpenAIRE

    Toda, Kenji; Kawakami, Yoshitaka; Kousaka, Shin-ichiro; Ito, Yutaka; Komeno, Akira; Uematsu, Kazuyoshi; Sato, Mineo

    2006-01-01

    We focus on the development of new silicate phosphors for a white LED. In the europium doped silicate system, four LED phosphor candidates-Li_2SrSiO_4:Eu^, Ba_9Sc_2Si_6O_:Eu^, Ca_3Si_2O_7:Eu^ and Ba_2MgSi_2O_7:Eu^ were found. Luminescent properties under near UV and visible excitation were investigated for the new Eu^ doped LED silicate phosphors. These new phosphors have a relatively strong absorption band in a long wavelength region.

  3. Persistent luminescence, TL and OSL characterization of beta irradiated SrAl2O4:Eu2+, Dy3+ combustion synthesized phosphor

    International Nuclear Information System (INIS)

    Zúñiga-Rivera, N.J.; García, R.; Rodríguez-Mijangos, R.; Chernov, V.; Meléndrez, R.; Pedroza-Montero, M.; Barboza-Flores, M.

    2014-01-01

    The persistent luminescence (PLUM), thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of strontium aluminates co-doped with Eu +2 and Dy +3 exposed to beta radiation is reported. The phosphor was synthesized by the combustion synthesis method employing a highly exothermic redox reaction between the metal nitrates [Al(NO 3 ) 3 , Sr(NO 3 ) 2 , Eu(NO 3 ) 3 and Dy(NO 3 ) 3 ] and organic fuel carbohydrazide (CH 6 N 4 O). The long decay PLUM emission, TL and OSL were measured as a function of beta radiation dose. A wide emission band centered at 510 nm (green) related to Eu 2+ ions and lattice defects were observed for the synthesized samples. The presence of a variety of defects and aggregates were responsible for the observed broad 100 °C peaked TL glow curve of the irradiated sample which is composed of several overlapped TL peaks. The existence of multiple trapping levels, with different trapping/detrapping probabilities, is behind the particular features for the PLUM, TL and OSL emissions. We conclude that in the SrAl 2 O 4 :Eu 2+ , Dy 3+ phosphors, the low temperature TL peaked around 30–75 °C is responsible for the PLUM emission and those around 100 °C were related to very stable trapping states which provide suitable radiation storage properties to be used as a PLUM/TL/OSL radiation phosphor

  4. Underground Storage Tanks - Storage Tank Locations

    Data.gov (United States)

    NSGIC Education | GIS Inventory — A Storage Tank Location is a DEP primary facility type, and its sole sub-facility is the storage tank itself. Storage tanks are aboveground or underground, and are...

  5. Advances in the synthesis of new Europium doped CaSO4 phosphors and their thermoluminescence characterization

    International Nuclear Information System (INIS)

    Bernal, R.; Garcia-Haro, A.R.; Machi, L.; Brown, F.; Perez-Salas, R.; Castano, V.M.; Cruz-Vazquez, C.

    2008-01-01

    Novel self-agglomerating Eu doped CaSO 4 phosphors were synthesized by a cheap, easy, and environmental friendly chemical route. Pellet-shaped sintered samples were obtained without any binding material, and exposed to beta particle irradiation. The thermoluminescence (TL) response in the 0.08-2.6 Gy dose range increased linearly as the radiation dose increased. Glow curves exhibit the most intense maximum close to 200 deg. C, and two much less intense maxima at 250 and 330 deg. C when a 5 deg. C/s heating rate is used. No TL peaks shift is observed when dose changes, which is characteristic of first order kinetics TL processes. The whole glow curve displays a remarkable stability under storage at room temperature. The main peak intensity is 2.5 times greater than that of the TLD-100. The method here reported can be used to synthesize CaSO 4 with other dopants

  6. Impact of pH and application time of meta-phosphoric acid on resin-enamel and resin-dentin bonding.

    Science.gov (United States)

    Cardenas, A F M; Siqueira, F S F; Bandeca, M C; Costa, S O; Lemos, M V S; Feitora, V P; Reis, A; Loguercio, A D; Gomes, J C

    2018-02-01

    To evaluate the immediate microshear resin-enamel bond strength (μSBS) and the immediate and 6-month microtensile bond strength (μTBS) and nanoleakage (NL) of the adhesive interface performed by different pHs of 40% meta-phosphoric acid (MPA) were compared with conventional 37% ortho-phosphoric acid (OPA) under different application times. Additionally, the enamel etching patterns were evaluated and the chemical/morphological changes induced by these differents groups were evaluated. One hundred and ninety-eight extracted human molars were randomly assigned into experimental groups according to the combination of independent variables: Acid [37% ortho-phosphoric acid (OPA), 40% meta-phosphoric acid (MPA) at pHs of: 0.5, 1 and 2] and Application Time [7, 15 and 30s]. Enamel-bond specimens were prepared and tested under μSBS. Resin-dentin beams were tested under μTBS tested immediately or after 6-months of water storage. Nanoleakage was evaluated using bonded-beams of each tooth/time-period. Enamel etching pattern and chemical and ultra-morphology analyses were also performed. The μSBS (MPa) data were subjected to a two-way repeated measures ANOVA (Acid vs. Application time). For μTBS, Acid vs application time vs storage time data were subjected to three-way ANOVA and Tukey's test (α = 0.05). MPA pH 0.5 showed μTBS similar to OPA, independently of the application time on enamel (p>0.05) or dentin (p>0.05). OPA provided higher nanoleakage values than MPA (p = 0.003). Significant decreases in TBS and increases in NL were only observed for OPA after 6 months (p = 0.001). An increase in the application time resulted in a more pronounced etching pattern for MPA. Chemical analysis showed that dentin demineralized by MPA depicted peaks of brushite and octacalcium phosphate. MPA exposed less collagen than OPA. However, optimal results for MPA were dependent on pH/application time. The use of 40% meta-phosphoric acid with a pH of 0.5 is an alternative acid

  7. Long-wave UVA radiation excited warm white-light emitting NaGdTiO4: Tm3+/Dy3+/Eu3+ ions tri-doped phosphors: Synthesis, energy transfer and color tunable properties

    International Nuclear Information System (INIS)

    Bharat, L. Krishna; Du, Peng; Yu, Jae Su

    2016-01-01

    NaGdTiO 4 (NGT) phosphors doped with different activator ions (Tm 3+ , Dy 3+ , and Eu 3+ ) were synthesized by a conventional solid-state reaction method in an ambient atmosphere. These phosphors were characterized by scanning electron microscope images, transmission electron microscope images, X-ray diffraction patterns, Fourier transform infrared spectra, and photoluminescence spectra. All the samples were crystallized in an orthorhombic phase with a space group of Pbcm (57). In Tm 3+ /Dy 3+ ions co-doped samples, white-light emission was observed under near-ultraviolet (NUV) excitation. In addition, the energy transfer between Tm 3+ and Dy 3+ ions was proved to be a resonant type via an electric dipole–dipole mechanism and the critical distance of energy transfer was calculated to be 19.91 Å. Furthermore, Tm 3+ /Dy 3+ /Eu 3+ ions tri-doped NGT phosphors demonstrated warm white-light emission by appropriately tuning the activator content, based on the principle of energy transfer. These NUV wavelength excitable phosphors exhibit great potential as a single-phase full-color emitting phosphor for white light-emitting diode applications. - Highlights: • The pebble shaped NaGdTiO 4 particles were prepared by solid-state reaction method. • Tm 3+ and Dy 3+ single doping gives respective blue and cool white light emission. • The Tm 3+ /Dy 3+ ions co-doped samples give CIE values near to standard white light. • Addition of Eu 3+ ions shifts the CIE values towards warm white light region. • This single phase white light emitting phosphors have lower CCT values (<5000 K).

  8. A novel KMgPO{sub 4}:Tb{sup 3+}(KMPT) phosphor for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Palan, C.B., E-mail: chetanpalan27@gmail.com [Department of Physics, Sant Gadge Baba Amravati University, Amravati 44602 (India); Bajaj, N.S. [Department of Physics, Toshniwal ACS College, Sengaon, Hingoli 431542 (India); Soni, A. [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai 400094 (India); Omanwar, S.K. [Department of Physics, Sant Gadge Baba Amravati University, Amravati 44602 (India)

    2016-08-15

    The polycrystalline sample of KMgPO{sub 4}:Tb{sup 3+}(KMPT) phosphor was successfully synthesized by using solid state method. The X-ray powder diffraction, photoluminescence (PL) emission and excitation spectra, thermoluminescence (TL) and optically stimulated luminescence (OSL) were thoroughly measured. The PL spectra of as-prepared KMPT phosphor showed characteristic blue-green emission, when excited by 226 nm under UV excitation. The optimum PL intensity was observed at 0.01 mol concentration of Tb{sup 3+}ions and this phosphor used for remaining studies. The TL glow curve of KMPT phosphor consist two characterized peaks, which were deconvoluted and the kinetic parameters i.e. trap depth or activation energy, order of kinetic and frequency factor determined by using peak shape method. TL sensitivity of KMPT phosphors was found to be 10% than that of TL sensitivity of TLD-500 phosphor. The OSL sensitivity of KMPT was 0.92 times than OSL sensitivity of α-Al{sub 2}O{sub 3}:C phosphor. The OSL decay curve KMPT phosphor consist of three component having photoionization cross sections were found to be 0.26548×10{sup −17}, 0.220×10{sup −17}, 2.92×10{sup −17} cm{sup 2}. The KMPT phosphor showed linear dose response in range 100–6000 mGy and fading of KMPT phosphor was found to be 31% in 15 days. The Minimum detectable dose (MDD) was found to be 0.39 mGy with corresponding 3σ back ground. The phosphor shows good dosimetry properties such as sensitivity, dose response, MDD, Fading.

  9. ZnO-nanorods: A possible white LED phosphor

    Science.gov (United States)

    Sarangi, Sachindra Nath; T., Arun; Ray, Dinseh K.; Sahoo, Pratap Kumar; Nozaki, Shinji; Sugiyama, Noriyuki; Uchida, Kazuo

    2017-05-01

    The white light-emitting diodes (LEDs) have drawn much attention to replace conventional lighting sources because of low energy consumption, high light efficiency and long lifetime. Although the most common approach to produce white light is to combine a blue LED chip and a yellow phosphor, such a white LED cannot be used for a general lighting application, which requires a broad luminescence spectrum in the visible wavelength range. We have successfully chemically synthesized the ZnO nanorods showing intense broad luminescence in the visible wavelength range and made a white LED using the ZnO nanorods as phosphor excited with a blue LED. Their lengths and diameters were 2 - 10 μm and 200 - 800 nm, respectively. The wurtzite structure was confirmed by the x-ray diffraction measurement. The PL spectrum obtained by exciting the ZnO nanorods with the He-Cd laser has two peaks, one associated with the near band-edge recombination and the other with recombination via defects. The peak intensity of the near band-edge luminescence at 388 nm is much weaker than that of the defect-related luminescence. The latter luminescence peak ranges from 450 to 850 nm and broad enough to be used as a phosphor for a white LED. A white LED has been fabricated using a blue LED with 450 nm emission and ZnO nanorod powders. The LED performances show a white light emission and the electroluminescence measurement shows a stiff increase in white light intensity with increasing blue LED current. The Commission International de1'Eclairage (CIE) chromaticity colour coordinates of 450 nm LED pumped white emission shows a coordinate of (0.31, 0.32) for white LED at 350 mA. These results indicate that ZnO nanorods provides an alternate and effective approach to achieve high-performance white LEDs and also other optoelectronic devices.

  10. Process for recovering uranium from wet process phosphoric acid

    International Nuclear Information System (INIS)

    Pyrih, R.Z.; Rickard, S.; Carrington, F.

    1982-01-01

    A process for recovering uranium from phosphoric acid solutions uses an acidified alkali metal carbonate solution for the second-stage strip of uranyl uranium from the ion-exchange solution. The stripped solution is then recycled to the ion-exchange circuit. In the first stripping stage the ion-exchange solution containing the recovered uranyl uranium and an inert organic diluent is stripped with ammonium carbonate, producing a slurry of ammonium uranyl tricarbonate. The second strip, with a solution of 50-200 grams per litre of sodium carbonate eliminates the problems of inadequate removal of phosphorus, iron and vanadium impurities, solids accumulation, and phase separation in the strip circuit

  11. Process for recovering uranium from wet process phosphoric acid (III)

    International Nuclear Information System (INIS)

    Pyrih, R.Z.; Rickard, R.S.; Carrington, O.F.

    1983-01-01

    Uranium is conventionally recovered from wet-process phosphoric acid by two liquid ion exchange steps using a mixture of mono- and disubstituted phenyl esters of orthophosphoric acid (OPPA). Efficiency of the process drops as the mono-OPPA is lost preferentially to the aqueous phase. This invention provides a process for the removal of the uranium process organics (OPPA and organic solvents) from the raffinate of the first liquid ion exchange step and their return to the circuit. The process organics are removed by a combination flotation and absorption step, which results in the recovery of the organics on beads of a hydrophobic styrene polymer

  12. The optimisation study of tbp synthesis process by phosphoric acid

    International Nuclear Information System (INIS)

    Amedjkouh, A.; Attou, M.; Azzouz, A.; Zaoui, B.

    1995-07-01

    The present work deals with the optimisation study of TBP synthesis process by phosphoric acid. This way of synthesis is more advantageous than POCL3 or P2O5 as phosphatant agents. these latters are toxic and dangerous for the environnement. The optimisation study is based on a series of 16 experiences taking into account the range of variation of the following parameters : temperature, pressure, reagents mole ratio, promoter content. the yield calculation is based on the randomisation of an equation including all parameters. the resolution of this equation gave a 30% TBP molar ratio. this value is in agreement with that of experimental data

  13. Phosphors doped with Dy3+ and Gd3+ for lighting

    International Nuclear Information System (INIS)

    Su, Q; Pei, Z.; Zeng, Q.; Chi, L.

    1998-01-01

    Full text: Some heavy lanthanide ions with even atomic number such as Dy 3+ and Gd 3+ are abundant in the ion adsorption type deposit of China. Their price is cheap and they have specific spectroscopic properties which can be used as phosphors. Dy 3i on has two dominant bands in the emission spectrum. The yellow band (575 nm) corresponds to the hypersensitive transition 4 F 9/2 → 6 H 13/2 (ΔL=2, ΔJ=2), and the blue band (485 nm) corresponds to the 4 F 9/2 → 6 H 15/2 transition. Factors which influence on the yellow- to-blue intensity ratio (Y/B) were investigated. Adjusting to a suitable Y/B, Dy 3+ will emit white light with high colour temperature and can be used for lighting. But Dy 3+ ion has only narrow excitation bands of f-f transitions ranging from 300-500 nm, no broad excitation band such as charge transfer band or f-d transition band exists in the UV region 200-300 nm. Hence its luminescent efficiency is low when it is excited by UV radiation emitted from the mercury plasma. This is one of the drawbacks to its use as lamp phosphor. However, this can be overcome by sensitisation with Gd 3+ , Pb 2+ or other sensitisers such as vanadate shown in this report. Gd 3+ is not only a good matrix, but also a good sensitiser. Using its 8 S 7/2 → 6 D, 6 I and 6 P transitions, the UV excitation energy can be absorbed and transferred to the activator such as Dy 3+ . Therefore, in some cases Gd 3+ is better than Y 3+ which is optical inert as a matrix. For the phosphor Ca 1.96 Pb 0.04 RE 7.9 Dy 0.1 (SiO 4 ) 6 O 2 prepared by sol-gel method, the intensity of Dy 3+ in the Gd 3+ compound (RE=Gd 3+ ) is six times that in the Y 3+ compound. Some new phosphors doped with Dy 3+ and Gd 3+ prepared in our laboratory are reported

  14. Diagnostic phosphors for photon beams at the ALS and APS

    International Nuclear Information System (INIS)

    Shu, Deming; Warwick, T.; Johnson, E.D.

    1991-01-01

    Some tests have been made of phosphors for photon beam diagnosis. Plasma sprayed coatings were checked for damage and decay during a period of several ampere-hours of irradiation from the NSLS Xray ring. Surface temperatures were measured and extrapolated to give an indication of the temperatures expected in more powerful photon beams. Based on our findings we have chosen plasma-sprayed coatings of Europium-doped Yttrium Oxide as the best candidate for use on masks and flags in ''white'' photon beams of the new facilities. 4 refs., 2 figs

  15. Alternative processes for uranium recovery from phosphoric acid

    International Nuclear Information System (INIS)

    Duarte Neto, J.; Santos Benedetto, J. dos; Aquino, J.A. de

    1987-01-01

    Two processes of solvent extraction using D 2 EHPATOPO synergistic mixture, in order to recover uranium from phosphoric acid proceeding from physical and chemical treatments of the phosphorus-uraniferous ore of Itataia-CE, Brazil, are studied. The steps of each process were studied in laboratory and pilot scales. The flow charts for both processes with detailed description of each step, the operational conditions, the mass balances, the results obtained and the description of pilot units, are presented. (M.C.K.) [pt

  16. Separation of uranium from molybdenum by alkyl phosphoric acid extraction

    Energy Technology Data Exchange (ETDEWEB)

    Zhongshi, Li

    1986-08-01

    The regularities of separation of uranium from molybdenum by alkyl phosphoric acid extraction are described. Two parameters, i.e., density ratio of uranium to molybdenum in organic phase at first stage and density of uranium in raffinate at last stage are presented. The relationship between these parameters and purity of molybdenum and uranium products is given. The method of adjusting and controlling these parameters in experiments and production is worked out. The technical key problem in comprehensive utilization of sedimentary type uranium ore containing molybdenum with close concentration of these to elements has been solved.

  17. Fluorimetrich determination of uranium in mineral samples and phosphoric solutions

    International Nuclear Information System (INIS)

    Pupo Gonzales, I.; Cuevillas, J.; Estevez, J.

    1991-01-01

    In this paper an analytical technique for the determination of uranium in different cuban minerals and acid leaching liquors of phosphorites is proposed. The method used for solid samples includes their disolution and further dilution of the solution obtained. For liquid samples dilution is the only intermediate step used. A study of HNO3 concentration (pH) was made in fluorimetric measurements. The method was applied to the uranium analysis in two IAEA standard reference samples (phosphate base), in natural phosphorites and a synthetic one, in clays and phosphoric liquors. The results agree with those obtained by other methods

  18. Fuel storage

    International Nuclear Information System (INIS)

    Palacios, C.; Alvarez-Miranda, A.

    2009-01-01

    ENSA is a well known manufacturer of multi-system primary components for the nuclear industry and is totally prepared to satisfy future market requirements in this industry. At the same time that ENSA has been gaining a reputation world wider for the supply of primary components, has been strengthening its commitment and experience in supplying spent fuel components, either pool racks or storage and transportation casks, and offers not only fabrication but also design capabilities for its products. ENSA has supplied Spent Fuel Pool Racks, in spain, Finland, Taiwan, Korea, China, and currently it is in the process of licensing its own rack design in the United States of America for the ESBWR along with Ge-Hitachi. ENSA has supplied racks for 20 pools and 22 different reactors and it has also manufactured racks under all available technologies and developed a design known as Interlock Cell Matrix whose main features are outlined in this article. Another ENSA achievement in rack technology is the use of remote control for re-racking activities instead of using divers, which improves the ALARA requirements. Regarding casks for storage and transportation, ENSA also has al leading worldwide position, with exports prevailing over the Spanish market where ENSA has supplied 16 storage and transportation casks to the Spanish nuclear power Trillo. In some cases, ENSA acts as subcontractor for other clients. Foreign markets are still a major challenge for ENSA. ENSA-is well known for its manufacturing capabilities in the nuclear industry, but has been always involved in design activities through its engineering division, which carries out different tasks: components Design; Tooling Design; Engineering and Documentation; Project Engineering; Calculations, Design and Development Engineering. (Author)

  19. Hydrothermal synthesis and luminescence of CaMO4:RE3+ (M=W, Mo; RE=Eu, Tb) submicro-phosphors

    International Nuclear Information System (INIS)

    Lei Fang; Yan Bing

    2008-01-01

    Submicrometer crystalline CaMO 4 :RE 3+ (M=W, Mo; RE=Eu, Tb) phosphors with a sheelite structure have been synthesized via the hydrothermal process, which were characterized by X-ray powder diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), X-ray-excited luminescence (XEL), UV-vis diffuse reflectance spectra (UV-vis DRS) and scanning electron microscopy (SEM), respectively. The XRD patterns show that both CaWO 4 and CaMoO 4 have the same structure with space group I41/a. The SEM images indicate that the optimal hydrothermal temperature is 120 deg. C for the particles that aggregate with the increase of temperature. The bands ranging from 380 to 510 nm in the XEL spectra of CaWO 4 :Eu 3+ can be attributed to the charge transfer state from the excited 2p orbits of O 2- to the empty orbits of the central W 6+ of the tungstate groups. The comparison between photoluminescent lifetimes and quantum efficiencies of the two phosphors was also investigated in detail. - Graphical abstract: Submicro-crystalline Eu 3+ -activated tungstate CaWO 4 :RE 3+ phosphors with a sheelite structure have been synthesized via the hydrothermal process; the morphology was determined from the hydrothermal temperature. Scanning electron microscopy (SEM) images show that CaWO 4 :Eu 3+ exhibits spherical particles, which can be controlled by the reaction parameters

  20. Underground storage

    Energy Technology Data Exchange (ETDEWEB)

    1965-06-10

    A procedure is described for making an underground storage cavity in a soluble formation. Two holes are drilled, and fluid is pumped into the first hole. This fluid is a non-solute for the formation material. Then pressure is applied to the fluid until the formation is fractured in the direction of the second hole. More non-solute fluid is injected to complete the fracture between the 2 holes. A solute fluid is then circulated between the 2 holes, which results in removal of that part of the formation next to the fracture and the forming of a chamber.

  1. Pumped storage

    International Nuclear Information System (INIS)

    Strauss, P.L.

    1991-01-01

    The privately financed 1,000 MW Rocky Point Pumped Storage Project located in central Colorado, USA, will be one of the world's highest head, 2,350 feet reversible pump/turbine projects. The project will offer an economical supply of peaking power and spinning reserve power to Colorado and other southwestern states. This paper describes how the project will be made compatible with the environmental conditions in the project area and the type of terrestrial mitigation measures that are being proposed for those situations where the project impacts the environment, either temporarily or permanently

  2. Influence of dome phosphor particle concentration on mid-power LED thermal resistance

    NARCIS (Netherlands)

    Alexeev, A.; Martin, G.; Hildenbrand, V.D.; Bosschaart, K.J.

    2016-01-01

    The modern white mid-power LEDs usually contain phosphor particles encapsulated in silicone dome material. The particles convert the blue light emitted from the epitaxial layer and play significant role in thermal processes of LED packages. In this paper the influence of the phosphor particles

  3. Study of the mechanism and kinetics of the reduction of uranyl ions in phosphoric acid solutions

    International Nuclear Information System (INIS)

    El Kacemi, K.; Tyburce, B.; Belcadi, S.

    1982-01-01

    The electrochemical reduction of uranyl ions in 0.1 to 9 M phosphoric acid has been investigated by polarography, cyclic voltammetry, chronopotentiometry and potentiostatic coulometry. In concentrated phosphoric acid solutions (H 3 PO 4 3 PO 4 concentrations. So, when the concentration of U(VI) increases and/or that of H 3 PO 4 reduces, the system becomes reversible. (author)

  4. Continuous tests of Phosphoric Acid - dihydrate process - from phosphatic concentrate of Itataia-CE ore

    International Nuclear Information System (INIS)

    Santos Benedetto, J. dos.

    1984-01-01

    A consolidation of principal studies and continuous tests done with phosphatic concentrated of Itataia ore intending phosphoric acid production by humid-route dihydrate way process is presented. The production of phosphoric acid is applied in uranium extraction process by solvents. (author) [pt

  5. Study of some thermoluminescent phosphors for the dosimetry of ionizing radiations

    International Nuclear Information System (INIS)

    Jaafari, M.

    1983-01-01

    Thermoluminescence dosimetry techniques are reviewed and interactions radiation matter are recalled. The need for new phosphors is evidenced. Numerous phosphors are examined and calcium, strontium and barium sulfides are synthetized and deposited on glass supports. The thermoluminescence of the dosimeters obtained with these materials is analyzed [fr

  6. Alternative magnesium source for phosphorous recovery – a feasibility and economic analysis

    DEFF Research Database (Denmark)

    Quist-Jensen, Cejna Anna; Jørgensen, Mads Koustrup; Christensen, Morten Lykkegaard

    Conventional reservoirs of phosphorous are in high risk of depletion in near future, thus nontraditional and sustainable recovery-practices are essential to ensure its adequate supply in future. Today phosphorous is being recovered from wastewater at industrial scale by addition of MgCl2. However...

  7. Preparation of MAl 2 O 4 : Eu 2+ , Sm 3+ (M = Ca, Sr, Ba) Phosphors ...

    African Journals Online (AJOL)

    A series of MAl2O4: Eu2+, Sm3+ (M = Ca, Sr, Ba) phosphors was prepared by the combustion method, and the influence of these alkaline earth metals on the structure and luminescent performances for these phosphors was investigated. A relationship was established between their composition, crystallization capacity and ...

  8. New NaSrPO4:Sm phosphor as orange-red emitting material

    Indian Academy of Sciences (India)

    Because NaSr1−xPO4:xSm3+ phosphor features a high colour-rendering index and chemical stability, it is potentially ... use blue LED chips (GaN or InGaN) with a yellow phosphor ... excitation by doping Sm3+ rare earth ions into a suitable.

  9. Combustion synthesis of Eu and Dy activated Sr3(VO4)2 phosphor ...

    Indian Academy of Sciences (India)

    phosphor as well as Sr3(VO4)2:Dy is blue and yellow emitting phosphor for solid state lighting i.e. white LEDs. The ... 2004; Pang et al 2004) doped with rare earth has expanded ... controlled since the LED light output (intensity and colour).

  10. Eu and Sr2CeO4 : Eu phosphors suitable for near ultraviolet excitation

    Indian Academy of Sciences (India)

    Administrator

    The study on white light phosphors suitable for near- ultraviolet (nUV) ... Rare earth ion-doped phosphors have been used in varied fields ... practical applications. .... by naked eyes. ... induced by Sr2CeO4 host matrix (Arunachalam Laxmanan.

  11. Synthesis and photoluminescence of novel red-emitting ZnWO₄: Pr³⁺, Li⁺ phosphors.

    Science.gov (United States)

    Wang, Ke; Feng, Wenlin; Feng, Xu; Li, Yao; Mi, Peng; Shi, Shasha

    2016-02-05

    Zn0.997WO4: Pr(3+)(0.003) and different concentrations (0.1 mol% to 0.9 mol%) of Pr, Li co-doped ZnWO4 red phosphors were prepared by means of solid-state reaction process. The crystalline, surface morphology and luminescent properties of Zn0.997WO4: Pr(3+)(0.003) and Zn(1-x-y)WO4: xPr(3+), yLi(+) phosphors were investigated by the X-ray diffraction patterns (XRD), scanning electron microscope (SEM) and fluorescent measurements. From powder XRD analysis, the formation of monoclinic structure with C(2/h) point-group symmetry and P(2/c) space group of the as-synthesized samples is confirmed. The SEM image showed that surface morphology of the phosphor powder is irregular cylindricality. The luminescent spectra are dominated by the red emission peaks at 607, 621 and 643 nm, respectively, radiated from the (1)D2→(3)H4, (3)P0→(3)H6 and (3)P0→(3)F2 transitions of Pr(3+) ions. The concentrations of the highest luminescent intensity is determined at 0.3 mol% Pr(3+) and 0.3 mol% Li co-doped ZnWO4 powder crystal, and the peak intensity is improved more than 3 times in comparison with that of 0.3 mol% Pr(3+) single-doped ZnWO4. The enhanced luminescence comes from the improved crystalline and from the charge compensation of Li(+) ions. The decay curve and CIE chromaticity coordinates of as-prepared samples are also studied in detail. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Determination of anions in pure and commercial phosphoric acid by ion chromatography and manual of 792 basic IC

    International Nuclear Information System (INIS)

    Al-Kabani, F.; Abdulbaki, M. K.

    2007-01-01

    A method for determination of anions in pure and concentrated phosphoric and samples (85%) and commercial phosphoric acid ion chromatography was developed, in order to control the specification of phosphoric acid produced in the pilot plant for phosphoric acid purification. The accuracy of the method was studied and the standard deviation was found to be between 0.09 and 0.10. Operation instructions of 792 Basic IC was described. (author)

  13. Process for the winning of a concentrate containing uranium and purified phosphoric acid, as well as the concentrate containing uranium and purified phosphoric acid obtained by this process

    International Nuclear Information System (INIS)

    1980-01-01

    The uranium containing concentrate and purified phosphoric acid are obtained by treating wet phosphoric acid with an inorganic fluorine compound (ammonium fluoride) and an aliphatic ketone (acetone) in the presence of a reducing agent (finely divided iron). The ketone is added first and the formed uranium precipitate is separated from the solution. If the fluorine compound is added first, the yield is lowered by a factor of 2. (Th.P.)

  14. Phosphors for near UV-Emitting LED's for Efficacious Generation of White Light

    Energy Technology Data Exchange (ETDEWEB)

    McKittrick, Joanna [Univ. of California, San Diego, CA (United States)

    2013-09-30

    1) We studied phosphors for near-UV (nUV) LED application as an alternative to blue LEDs currently being used in SSL systems. We have shown that nUV light sources could be very efficient at high current and will have significantly less binning at both the chip and phosphor levels. We identified phosphor blends that could yield 4100K lamps with a CRI of approximately 80 and LPWnUV,opt equal to 179 for the best performing phosphor blend. Considering the fact that the lamps were not optimized for light coupling, the results are quite impressive. The main bottleneck is an optimum blue phosphor with a peak near 440 nm with a full width half maximum of about 25 nm and a quantum efficiency of >95%. Unfortunately, that may be a very difficult task when we want to excite a phosphor at ~400 nm with a very small margin for Stokes shift. Another way is to have all the phosphors in the blend having the excitation peak at 400 nm or slightly shorter wavelength. This could lead to a white light source with no body color and optimum efficacy due to no self-absorption effects by phosphors in the blend. This is even harder than finding an ideal blue phosphor, but not necessarily impossible. 2) With the phosphor blends identified, light sources using nUV LEDs at high current could be designed with comparable efficacy to those using blue LEDs. It will allow us to design light sources with multiple wattages using the same chips and phosphor blends simply by varying the input current. In the case of blue LEDs, this is not currently possible because varying the current will lower the efficacy at high current and alter the color point. With improvement of phosphor blends, control over CRI could improve. Less binning at the chip level and also at the phosphor blend level could reduce the cost of SSL light sources. 3) This study provided a deeper understanding of phosphor characteristics needed for LEDs in general and nUV LEDs in particular. Two students received Ph.D. degrees and three

  15. Gas storage materials, including hydrogen storage materials

    Science.gov (United States)

    Mohtadi, Rana F; Wicks, George G; Heung, Leung K; Nakamura, Kenji

    2013-02-19

    A material for the storage and release of gases comprises a plurality of hollow elements, each hollow element comprising a porous wall enclosing an interior cavity, the interior cavity including structures of a solid-state storage material. In particular examples, the storage material is a hydrogen storage material such as a solid state hydride. An improved method for forming such materials includes the solution diffusion of a storage material solution through a porous wall of a hollow element into an interior cavity.

  16. Surface-Plasmon-Enhanced Emissions of Phosphors with Au Nanoparticles Embedded in ITO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ja-Yeon [Korea Photonics Technology Institute (KOPTI), Gwangju (Korea, Republic of); Oh, Seung Jong; Park, Hyun-Sun; Kim, Min-Woo; Cho, Yoo-Hyun; Kwon, Min-Ki [Chosun University, Gwangju (Korea, Republic of)

    2017-03-15

    Au nanoparticles were embedded in a transparent conducting layer of indium tin oxide in order to evaluate the feasibility of applying a surface-plasmon (SP)-enhanced phosphor to light-emitting diodes (LEDs). The efficiency of the phosphor was improved by energy matching between the phosphor and the SP of the Au nanoparticles. After the density of the Au nanoparticles and the thickness of the spacer layer had been optimized, the efficiency of a green phosphor was improved by 64% compared to that of an isolated green phosphor. This work provides a way to fabricate high-efficiency LEDs with high color-rendering indices and wide color gamuts in white LEDs.

  17. Initiation in the study of uranium recovery from the phosphoric acid

    Energy Technology Data Exchange (ETDEWEB)

    Anchondo Adalid, J M

    1974-01-01

    The loss of considerable amounts of uranium in the Mexican phosphoric acid industry makes it important to study economic methods of recovery; the studies can serve as a basis for the construction and operation of a pilot plant as a normal preliminary to larger-scale projects. Routine experimental techniques for solvent extraction were employed. Extraction efficiencies of the order of 90-95% were obtained using 0.09-0.18M solutions of a mixture of phosphoric octyl esters applied to 4 and 6M solutions of phosphoric acid (reagent grade) containing uranium in concentrations of 0.05-0.50g of U/sub 3/O/sub 8/ per litre of acid. The conclusion was reached that phosphoric octyl esters can be used for recovering uranium in satisfactory quantities from phosphoric acid solutions by means of solvent extraction, and that the uranium can be separated from the solvent by the established procedures.

  18. Combustion synthesis of red emitting borate host PDP phosphor YCaBO4: Eu3+

    International Nuclear Information System (INIS)

    Ingle, J.T.; Hargunani, S.P.; Sonekar, R.P.; Nagpure, P.A.; Omanwar, S.K.; Moharil, S.V.

    2012-01-01

    The red emitting borate host phosphor YCaBO 4 : Eu 3+ has been prepared by a novel solution combustion technique. The synthesis is based on the exothermic reaction between the fuel (Urea) and Oxidizer (Ammonium nitrate). The photoluminescence properties of the powder samples of YCaBO 4 : Eu 3+ has been investigated under UV and VUV excitation. The phosphor shows strong absorption in UV and VUV region and exhibits intense red emission upon excited by 254 nm UV and 173 nm VUV radiation. Under UV 254 nm excitation, YCaBO 4 : Eu 3+ exhibits intense red emission around 610 nm. Under VUV excitation of 173 nm, the phosphor emits intense red emission around 610 nm and few weak emissions. These weak emissions could be suppressed by annealing the sample repeatedly at proper temperature and the borate phosphor YCaBO 4 : Eu 3+ could be a good red emitting phosphor for PDP display and mercury free lamps. (author)

  19. Zero- and two-dimensional hybrid carbon phosphors for high colorimetric purity white light-emission.

    Science.gov (United States)

    Ding, Yamei; Chang, Qing; Xiu, Fei; Chen, Yingying; Liu, Zhengdong; Ban, Chaoyi; Cheng, Shuai; Liu, Juqing; Huang, Wei

    2018-03-01

    Carbon nanomaterials are promising phosphors for white light emission. A facile single-step synthesis method has been developed to prepare zero- and two-dimensional hybrid carbon phosphors for the first time. Zero-dimensional carbon dots (C-dots) emit bright blue luminescence under 365 nm UV light and two-dimensional nanoplates improve the dispersity and film forming ability of C-dots. As a proof-of-concept application, the as-prepared hybrid carbon phosphors emit bright white luminescence in the solid state, and the phosphor-coated blue LEDs exhibit high colorimetric purity white light-emission with a color coordinate of (0.3308, 0.3312), potentially enabling the successful application of white emitting phosphors in the LED field.

  20. Self-adaptive phosphor coating technology for wafer-level scale chip packaging

    International Nuclear Information System (INIS)

    Zhou Linsong; Rao Haibo; Wang Wei; Wan Xianlong; Liao Junyuan; Wang Xuemei; Zhou Da; Lei Qiaolin

    2013-01-01

    A new self-adaptive phosphor coating technology has been successfully developed, which adopted a slurry method combined with a self-exposure process. A phosphor suspension in the water-soluble photoresist was applied and exposed to LED blue light itself and developed to form a conformal phosphor coating with self-adaptability to the angular distribution of intensity of blue light and better-performing spatial color uniformity. The self-adaptive phosphor coating technology had been successfully adopted in the wafer surface to realize a wafer-level scale phosphor conformal coating. The first-stage experiments show satisfying results and give an adequate demonstration of the flexibility of self-adaptive coating technology on application of WLSCP. (semiconductor devices)

  1. Determination of the activity concentration of 230Th in phosphoric acids produced in Brazil

    International Nuclear Information System (INIS)

    Taddei, M.H.T.; Ferreira, M.T.; Fukuma, H.T.; Xavier, T.T.; Sousa, F.V.T.S.

    2017-01-01

    The high uranium phosphate rock from Itataia, Brazil, was processed using the wet route in the dihydrate system to manufacture phosphoric acid. The uranium contained in phosphoric acid was recovered by the solvent extraction technique. The distribution of the long half-life radionuclides from the decay series of 238 U and 232 Th were evaluated in these processes. The 26 Ra, 228 Ra and 210 Pb radionuclides were found predominantly in phosphogypsum, while the isotopes of 228 Th, 230 Th and 232 Th predominated in phosphoric acid after extracting uranium. The main concern in the commercialization of phosphoric acid that will be produced in the Itataia plant is in relation to the content of 230 Th. This work determined the content of these radionuclides in phosphoric acid from different locations in the country in order to compare

  2. Initiation in the study of uranium recovery from the phosphoric acid

    International Nuclear Information System (INIS)

    Anchondo Adalid, J.M.

    1974-01-01

    The loss of considerable amounts of uranium in the Mexican phosphoric acid industry makes it important to study economic methods of recovery; the studies can serve as a basis for the construction and operation of a pilot plant as a normal preliminary to larger-scale projects. Routine experimental techniques for solvent extraction were employed. Extraction efficiencies of the order of 90-95% were obtained using 0.09-0.18M solutions of a mixture of phosphoric octyl esters applied to 4 and 6M solutions of phosphoric acid (reagent grade) containing uranium in concentrations of 0.05-0.50g of U 3 O 8 per litre of acid. The conclusion was reached that phosphoric octyl esters can be used for recovering uranium in satisfactory quantities from phosphoric acid solutions by means of solvent extraction, and that the uranium can be separated from the solvent by the established procedures. (author)

  3. Radiotracer investigation of phosphoric acid and phosphatic fertilizers production process

    International Nuclear Information System (INIS)

    Ben Abdelouahed, H.; Reguigui, N.

    2011-01-01

    In the phosphoric acid production process, the time a particle spends inside the chemical reactor (residence time) is of paramount importance to process engineers. Residence time distribution (RTD) gives information on the efficiency of the chemical reactor, on the efficiency of the process, and also the availabilities of the reactive volume for the reaction (active volume vs. dead volume). Traditionally, chemical engineers used chemical tracer to determine the RTD. However, first disadvantage is that the chemical tracer could not allow an online diagnosis: the samples containing chemical tracer have to go to a lab for analysis, second disadvantage is that the chemical tracer is less sensitive than radioactive ones because of its adsorption onto strata or its retention in rocks. Consequently, chemical tracer results are not always precise and cannot convincingly explain the multiple flow-path model. Radioactive tracers are the only tracers capable of measuring the active RTD with high degree of precision and give information on the internal recirculation rate. In this work, we will describe the application of radiotracer method for RTD measurement in the phosphoric acid production process and give results and discussion of each case encountered. (author)

  4. Process for extracting uranium from phosphoric acid solutions

    International Nuclear Information System (INIS)

    1977-01-01

    The description is given of a method for extracting uranium from phosphoric acid solutions whereby the previously oxided acid is treated with an organic solvent constituted by a mixture of dialkylphosphoric acid and trialkylphosphine oxide in solution in a non-reactive inert solvent so as to obtain de-uraniated phosphoric acid and an organic extract constituted by the solvent containing most of the uranium. The uranium is then separated from the extract as uranyl ammonium tricarbonate by reaction with ammonia and ammonium carbonate and the extract de-uraniated at the extraction stage is recycled. The extract is treated in a re-extraction apparatus comprising not less than two stages. The extract to be treated is injected at the top of the first stage. At the bottom of the first stage, ammonia is introduced counter current as gas or as an aqueous solution whilst controlling the pH of the first stage so as to keep it to 8.0 or 8.5 and at the bottom of the last stage an ammonium carbonate aqueous solution is injected in a quantity representing 50 to 80% of the stoichiometric quantity required to neutralize the dialkylphosphoric acid contained in the solvent and transform the uranium into uranyl ammonium tricarbonate [fr

  5. Absorption characteristics of Kupravas deposit clays modified by phosphoric acid

    International Nuclear Information System (INIS)

    Ruplis, A.; Mezinskis, G.; Chaghuri, M.

    1998-01-01

    Literature data suggested that clays may be used as sorbents for waste water treatment. The surface and sorption properties of minerals changes due to the influence of acid rains. The process of recession of clay properties has been modeled in laboratory by treatment of clays with mineral acids at higher temperature that in natural conditions. The present paper is devoted to the study of influence of phosphoric acid on the sorption properties of Kupravas deposit clays. Natural clay samples and samples treated with phosphoric acid were characterized by means of x-ray diffraction an differential thermal analysis (DTA) methods These methods were used also to identify the sample of Lebanese clays. X-ray diffraction analysis data show that the samples of clays from the deposit of Kuprava contain illite and kaolinite while sample of Lebanese clay contains quartz, calcite, and montmorillonite. DTA results show characteristic features of Kuprava clays described in reference with DTA of Lebanese clay clearly demonstrate the presence of large quantity of calcite

  6. Nitric-phosphoric acid oxidation of organic waste materials

    International Nuclear Information System (INIS)

    Pierce, R.A.; Smith, J.R.

    1995-01-01

    A wet chemical oxidation technology has been developed to address issues facing defense-related facilities, private industry, and small-volume generators such as university and medical laboratories. Initially tested to destroy and decontaminate a heterogenous mixture of radioactive-contaminated solid waste, the technology can also remediate other hazardous waste forms. The process, unique to Savannah River, offers a valuable alternative to incineration and other high-temperature or high-pressure oxidation processes. The process uses nitric acid in phosphoric acid; phosphoric acid allows nitric acid to be retained in solution well above its normal boiling point. The reaction converts organics to carbon dioxide and water, and generates NO x vapors which can be recycled using air and water. Oxidation is complete in one to three hours. In previous studies, many organic compounds were completely oxidized, within experimental error, at atmospheric pressure below 180 degrees C; more stable compounds were decomposed at 200 degrees C and 170 kPa. Recent studies have evaluated processing parameters and potential throughputs for three primary compounds: EDTA, polyethylene, and cellulose. The study of polyvinylchloride oxidation is incomplete at this time

  7. Ionic flotation of uranium contained in industrial phosphoric acid

    International Nuclear Information System (INIS)

    Jdid; Blazy; Bessiere

    1983-01-01

    A new process for uranium recovery from industrial phosphoric acid at 30% of P 2 O 5 is applied by the ionic flotation process. Research is carried out on determination of the nature of ionic species of U in H 3 PO 4 5.5 M and the behavior of reagents from CECA Co. in very acid media. Reagents able to form complexes directly with uranium and stable in phosphoric acid selected are: potassium ethylene diamine tetra (methylene phosphonate) (INIPOL AD32) and sodium dialkyldiphosphonate (34S). Uranium IV, obtained by reduction of uranium VI with iron powder, is precipitated by these reagents. Flotation of the precipitate obtained with INIPOL AD 32 is realized by addition of hexylamino bis (methylene phosphonic acid). A recovery of 80 wt% is obtained. Flotation of the coprecipitate 34S-U(IV) is obtained without any other additions because 34S is a surfactant. Metal recovery is better than 90% and the coprecipitate contains more than 10% U. The process is fast precipitation 10 minutes and flotation 5 minutes and is efficient even at 60 0 C [fr

  8. Radioactivity Content in Phosphoric Acid Used for Fertilizer Production

    International Nuclear Information System (INIS)

    Ibrahiem, N.M.; Hamed, A.A.

    2003-01-01

    Uranium content in phosphoric acid used fertilizer production was measured by alpha spectrometry, laser fluorimetry high resolution gamma spectrometry. Also, polonium-210 content was determined in phosphoric acid by alpha spectrometry. Uranium-234 and uranium-238 concentrations, measured by alpha spectroscopy, were found to be 601 and 507 Bq I -1 , respectively. Total uranium content obtained by laser fluorimetry was about 545 BqI - (45.4ppm). Gamma spectroscopy analysis gave the concentrations of 40 K, 238 U, 235 U, 214 Pb, 214 Bi and 208 TI, as 17,644,19.5, 1.2,1.3 and 9.4 Bq I -1 , respectively. Polonium-210 concentration was found to be about 3.1 Bq I -1 . Uranium-232 and polonium-208 were used as yield tracers, for alpha measurements of uranium and polonium, respectively. Samples of the tri-super phosphate (TSP) and single-super phosphate (SSP) fertilizers and the phosphogypsum produced were also analyzed by gamma spectroscopy. Uranium content in both phosphate fertilizers was 3205 and 1440 Bq Kg -1 for 238 U and 83 and 35 Bq Kg -1 for, 235 U respectively

  9. Potassium doped MWCNTs for hydrogen storage enhancement

    International Nuclear Information System (INIS)

    Adabi Qomi, S.; Gashtasebi, M.; Khoshnevisan, B.

    2012-01-01

    Here we have used potassium doped MWCNTs for enhancement of hydrogen storage process. XRD and SEM images have confirmed the doping of potassium. For studying the storage process a hydrogenic battery set up has been used. In the battery the working electrode has been made of the silver foam deposited by the doped MWCNTs electrophoretically.

  10. Biogeochemical Cycling of Iron and Phosphorous in Deep Saprolite

    Science.gov (United States)

    Buss, H. L.; Bruns, M. A.; Williams, J. Z.; White, A. F.; Brantley, S. L.

    2006-12-01

    Few microbiological studies have been conducted within the unsaturated zones between rooting depth and bedrock and thus the relationships between biological activity and mineral nutrient cycling in deep regolith are poorly understood. Here we investigate the weathering of primary minerals containing iron (hornblende and biotite) and phosphorous (apatite) and the role of resident microorganisms in the cycling of these elements in the deep saprolite of the Rio Icacos watershed in Puerto Rico's Luquillo Mountains. In the Rio Icacos watershed, which has one of the fastest documented chemical weathering rates of granitic rock in the world, the quartz diorite bedrock weathers spheroidally, producing a complex interface comprised of partially weathered rock layers called rindlets. This rindlet zone (0.2-2 m thick) is overlain by saprolite (2-8 m) topped by soil (0.5-1 m). With the objective of understanding interactions among mineral weathering, substrate availability and resident microorganisms, we made geochemical and microbiological measurements as a function of depth in 5 m of regolith (soil + saprolite) and examined mineral weathering reactions within a 0.5 m thick spheroidally weathering rindlet zone. We measured total cell densities, culturable aerobic chemoorganotrophs, and microbial DNA yields; and performed biochemical tests for iron-oxidizing bacteria in the regolith samples. Total cell densities, which ranged from 2.5 x 106 to 1.6 x 1010 g-1 regolith, were higher than 108 g-1 at three depths: in the upper 1 m, at 2.1 m, and between 3.7-4.9 m, just above the rindlet zone. Biochemical tests for aerobic iron-oxidizers were also positive at 0.15-0.6 m, at 2.1-2.4 m, and at 4.9 m depths. High proportions of inactive or unculturable cells were indicated throughout the profile by very low percentages of culturable chemoorganotrophs. The observed increases in total and culturable cells and DNA yields at lower depths were correlated with an increase in HCl

  11. SXLS storage ring design

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    X-ray lithography has emerged as a strong candidate to meet the demands of ever finer linewidths on integrated circuits, particularly for linewidths less than .25 microns. Proximity printing X-ray lithography makes use of soft X-rays to shadow print an image of a mask onto a semiconductor wafer to produce integrated circuits. To generate the required X-rays in sufficient quantities to make commercial production viable, electron storage rings have been proposed as the soft X-ray sources. Existing storage rings have been used to do the initial development work and the success of these efforts has led the lithographers to request that new rings be constructed that are dedicated to X-ray lithography. As a result of a series of workshops held at BNL [10.3] which were attended by both semiconductor and accelerator scientists, the following set of zeroth order specifications' on the light and electron beam of a storage ring for X-ray lithography were developed: critical wavelength of light: λ c = 6 to 10 angstroms, white light power: P = 0.25 to 2.5 watts/mrad, horizontal collection angle per port: θ = 10 to 50 mrad, electron beam sizes: σ x ∼ σ y y ' < 1 mrad

  12. Photocatalytic effects for the TiO2-coated phosphor materials

    International Nuclear Information System (INIS)

    Yoon, Jin-Ho; Jung, Sang-Chul; Kim, Jung-Sik

    2011-01-01

    Research highlights: → The photocatalytic behavior of the coupling of TiO 2 with phosphorescent materials. → The photobleaching of an MB aqueous solution under visible light irradiation. → The ALD TiO 2 -coated phosphor composite showed much higher photocatalytic reactivity. → The light emitted from the phosphors contributed to the photo-generation. - Abstract: This study investigated the photocatalytic behavior of the coupling of TiO 2 with phosphorescent materials. A TiO 2 thin film was deposited on CaAl 2 O 4 :Eu 2+ ,Nd 3+ phosphor particles by using atomic layer deposition (ALD), and its photocatalytic reaction was investigated by the photobleaching of an aqueous solution of methylene-blue (MB) under visible light irradiation. To clarify the mechanism of the TiO 2 -phosphorescent materials, two different samples of TiO 2 -coated phosphor and TiO 2 -Al 2 O 3 -coated phosphor particles were prepared. The photocatalytic mechanisms of the ALD TiO 2 -coated phosphor powders were different from those of the pure TiO 2 and TiO 2 -Al 2 O 3 -coated phosphor. The absorbance in a solution of the ALD TiO 2 -coated phosphor decreased much faster than that of pure TiO 2 under visible irradiation. In addition, the ALD TiO 2 -coated phosphor showed moderately higher photocatalytic degradation of MB solution than the TiO 2 -Al 2 O 3 -coated phosphor did. The TiO 2 -coated phosphorescent materials were characterized by transmission electron microscopy (TEM), Auger electron spectroscopy (AES) and X-ray photon spectroscopy (XPS).

  13. Imaging

    International Nuclear Information System (INIS)

    Kellum, C.D.; Fisher, L.M.; Tegtmeyer, C.J.

    1987-01-01

    This paper examines the advantages of the use of excretory urography for diagnosis. According to the authors, excretory urography remains the basic radiologic examination of the urinary tract and is the foundation for the evaluation of suspected urologic disease. Despite development of the newer diagnostic modalities such as isotope scanning, ultrasonography, CT, and magnetic resonsance imaging (MRI), excretory urography has maintained a prominent role in ruorradiology. Some indications have been altered and will continue to change with the newer imaging modalities, but the initial evaluation of suspected urinary tract structural abnormalities; hematuria, pyuria, and calculus disease is best performed with excretory urography. The examination is relatively inexpensive and simple to perform, with few contraindictions. Excretory urography, when properly performed, can provide valuable information about the renal parenchyma, pelvicalyceal system, ureters, and urinary bladder

  14. Novel developments in hydrogen storage, hydrogen activation and ionic liquids

    Energy Technology Data Exchange (ETDEWEB)

    Doroodian, Amir

    2010-12-03

    This dissertation is divided into three chapters. Recently, metal-free hydrogen activation using phosphorous compounds has been reported in science magazine. We have investigated the interaction between hydrogen and phosphorous compounds in presence of strong Lewis acids (chapter one). A new generation of metal-free hydrogen activation, using amines and strong Lewis acids with sterically demanding nature, was already developed in our group. Shortage of high storage capacity using large substitution to improve sterical effect led us to explore the amine borane derivatives, which are explained in chapter two. Due to the high storage capacity of hydrogen in aminoborane derivatives, we have explored these materials to extend hydrogen release. These compounds store hydrogen as proton and hydride on adjacent atoms or ions. These investigations resulted in developing hydrogen storage based on ionic liquids containing methyl guanidinium cation. Then we have continued to develop ionic liquids based on methyl guanidinium cation with different anions, such as tetrafluoro borate (chapter three). We have replaced these anions with transition metal anions to investigate hydrogen bonding and catalytic activity of ionic liquids. This chapter illustrates the world of ionic liquid as a green solvent for organic, inorganic and catalytic reactions and combines the concept of catalysts and solvents based on ionic liquids. The catalytic activity is investigated particularly with respect to the interaction with CO{sub 2}. (orig.)

  15. Holographic Optical Data Storage

    Science.gov (United States)

    Timucin, Dogan A.; Downie, John D.; Norvig, Peter (Technical Monitor)

    2000-01-01

    Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising

  16. Glandular dose and image quality control in mammography facilities with computerized radiography systems

    International Nuclear Information System (INIS)

    Dantas, Marcelino Vicente de Almeida

    2010-01-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. However, even though SF combinations have been improved and optimized over the years for breast imaging, there are some critical limitations, including a narrow exposure range, image artifacts, film processing problems, and inflexibility in image processing and film management. In recent years, digital mammography has been introduced in cancer screening programmes with the screen/film techniques gradually being phased out. Computed radiography (CR), also commonly known as photostimulable phosphor (PSP) imaging or storage phosphor, employs reusable imaging plates and associated hardware and software to acquire and to display digital projection radiographs. In this work, a protocol model was tested for performing image quality control and average glandular dose (AGD) evaluation in 19 institutions with computed radiography systems for mammography. The protocol was validated through tests at the Laboratorio de Radioprotecao Aplicada a Mamografia (LARAM) from the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). The image quality visual evaluation of CDMAM phantom showed that 53% of the facilities were able to produce images of excellent quality. Furthermore, the automated evaluation of image quality, using the analyze software cdcom.exe, showed that 57% of the images were considered to be of good quality. The detector linearity test showed that the CR response is very linear, where 95% of facilities evaluated were considered to be compliant. For the image noise was found that only 20% of facilities are in agreement with the parameters established for this test. The average glandular doses, which patients may be getting to perform an examination, were below the action levels

  17. Laser Based Phosphor Converted Solid State White Light Emitters

    Science.gov (United States)

    Cantore, Michael

    Artificial lighting and as a consequence the ability to be productive when the sun does not shine may be a profound achievement in society that is largely taken for granted. As concerns arise due to our dependence on energy sources with finite lifespan or environmentally negative effects, efforts to reduce energy consumption and create clean renewable alternatives has become highly valued. In the scope of artificial lighting, the use of incandescent lamps has shifted to more efficient light sources. Fluorescent lighting made the first big gains in efficiency over incandescent lamps with peak efficiency for mature designs reaching luminous efficacy of approximately 90 lm/W; more than three times as efficient as an incandescent lamp. Lamps based on light emitting diodes (LEDs) which can produce light at even greater efficiency, color quality and without the potential for hazardous chemical release from lamp failure. There is a significant challenge with LED based light sources. Their peak efficiency occurs at low current densities and then droops as the current density increases. Laser diodes (LDs) do not suffer from decreasing efficiency due to increased current. An alternative solid state light source using LDs has potential to make further gains in efficiency as well as allow novel illuminant designs which may be impractical or even impossible even with LED or other conventional sources. While similar to LEDS, the use of LDs does present new challenges largely due to the increased optical power density which must be accommodated in optics and phosphor materials. Single crystal YAG:Ce has been shown to be capable of enduring this more extreme operating environment while retaining the optical and fluorescing qualities desired for use as a wavelength converter in phosphor converted LD based white emitting systems. The incorporation of this single crystal phosphor in a system with a commercial laser diode with peak wall plug efficiency of 31% resulted in emission of

  18. Radionuclide concentrations in raw and purified phosphoric acids from Brazil and their processing wastes: implications for radiation exposures.

    Science.gov (United States)

    da Conceição, Fabiano Tomazini; Antunes, Maria Lúcia Pereira; Durrant, Steven F

    2012-02-01

    Radionuclides from the U and Th natural series are present in alkaline rocks, which are used as feedstock in Brazil for the production of raw phosphoric acid, which can be considered as a NORM (naturally occurring radioactive material). As a result of the purification of raw phosphoric acid to food-grade phosphoric acid, two by-products are generated, i.e., solid and liquid wastes. Taking this into account, the main aim of this study was to evaluate the fluxes of natural radionuclide in the production of food-grade phosphoric acids in Brazil, to determine the radiological impact caused by ingestion of food-grade phosphoric acid, and to evaluate the solid waste environmental hazards caused by its application in crop soils. Radiological characterization of raw phosphoric acid, food-grade phosphoric acid, solid waste, and liquid waste was performed by alpha and gamma spectrometry. The (238)U, (234)U, (226)Ra, and (232)Th activity concentrations varied depending on the source of raw phosphoric acid. Decreasing radionuclides activity concentrations in raw phosphoric acids used by the producer of the purified phosphoric acid were observed as follows: Tapira (raw phosphoric acid D) > Catalão (raw phosphoric acids B and C) > Cajati (raw phosphoric acid A). The industrial purification process produces a reduction in radionuclide activity concentrations in food-grade phosphoric acid in relation to raw phosphoric acid produced in plant D and single raw phosphoric acid used in recent years. The most common use of food-grade phosphoric acid is in cola soft drinks, with an average consumption in Brazil of 72 l per person per year. Each liter of cola soft drink contains 0.5 ml of food-grade phosphoric acid, which gives an annual average intake of 36 ml of food-grade phosphoric acid per person. Under these conditions, radionuclide intake through consumption of food-grade phosphoric acid per year per person via cola soft drinks is not hazardous to human health in Brazil

  19. Radiopacity of restorative composites by conventional radiography and digital images with different resolutions

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Raquel Venancio; Samento, Hugo Ramalho [Graduate Program in Dentistry, Federal University of Pelotas, Pelotas (Brazil); Duarte, Rosangela Marques; Raso, Sonia Saeger Meireles Monte; De Andrade Ana Karina Maciel; Anjos-Pontual Maria Luiza Dos [Dept. of Operative Dentistry, Federal University of Paraiba, Pelotas (Brazil)

    2013-09-15

    This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using 4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

  20. Photoluminescent and Thermoluminescent Studies of Dy3+ and Eu3+ Doped Y2O3 Phosphors.

    Science.gov (United States)

    Verma, Tarkeshwari; Agrawal, Sadhana

    2018-01-01

    Eu 3+ doped and Dy 3+ codoped yttrium oxide (Y 2 O 3 ) phosphors have been prepared using solid-state reaction technique (SSR). The prepared phosphors were characterized by X-ray diffractometer (XRD), energy dispersive X-ray (EDX) spectroscopy, scanning electron microscopy (SEM) and Fourier transforms infrared spectroscopy (FTIR) techniques. Photoluminescence (PL) and Thermoluminescence (TL) properties were studied in detail. PL emission spectra were recorded for prepared phosphors under excitation wavelength 254 nm, which show a high intense peak at 613 nm for Y 2 O 3 :Dy 3+ , Eu 3+ (1:1.5 mol %) phosphor. The correlated color temperature (CCT) and CIE analysis have been performed for the synthesized phosphors. TL glow curves were recorded for Eu 3+ doped and Dy 3+ codoped phosphors to study the heating rate effect and dose response. The kinetic parameters were calculated using peak shape method for UV and γ exposures through computerized glow curve deconvolution (CGCD) technique. The phosphors show second order kinetics and activation energies varying from 5.823 × 10 - 1 to 18.608 × 10 - 1  eV.

  1. X-ray investigation of phosphors for black-white television

    International Nuclear Information System (INIS)

    Lazowy, B.

    1975-01-01

    The investigations of phosphors made by means of the powder diffraction method are presented. The diffraction patterns has been obtained by means of the DRON-1 diffractometer, using the Ksub(α) copper radiation and a nickel filter. Reflex intensity was estimated, indexing was made and lattice constants for particular structure types were calculated. The objects of the investigations were the phosphors from various firms of white luminescence and home phosphors of white, blue and yellow luminescence. On the base of the results it was found that all investigated phosphors of yellow luminescence belonged to the hexagonal system. These phosphors, depending on baking conditions, have structure of regular symmetry. The phosphors of white luminescence are a mixture of hexagonal and regular phase and any changes in elementary cell sizes were not observed. All phosphors of white luminescence have analogous structure, positions of all reflexes are identical, negligible differences in their intensities occur only, which proves somewhat different arrangement of atoms in mixed crystals. (author)

  2. Electroluminescent efficiency of alternating current thick film devices using ZnS:Cu,Cl phosphor

    International Nuclear Information System (INIS)

    Sharma, Gaytri; Han, Sang Do; Kim, Jung Duk; Khatkar, Satyender P.; Rhee, Young Woo

    2006-01-01

    ZnS:Cu,Cl phosphor is prepared with the help of low intensity milling of the precursor material in two step firing process. The synthesized phosphor is used for the preparation of alternating current thick film electroluminescent (ACTFEL) devices with screen-printing method. The commission international de l'Eclairge (CIE) color co-ordinates of the ACTFEL devices prepared by these phosphor layers shows a shift from bluish-green to green region with the change in the amount of Cu in the phosphor. The various parameters to improve the efficiency and luminance of the devices have also been investigated. The brightness of the ac thick film EL device depends on the particle size of the phosphor, crystallinity, amount of binding material and applied voltage. The EL device fabricated with phosphor having average particle size of 25 μm shows maximum luminescence, when 60% phosphor concentration is used with respect to binding material. EL intensity is also linearly dependent on frequency. It is due the increase of excitation chances of the host matrix or dopant ions with increasing frequency

  3. Thermoluminescence dosimetric characteristics of thulium doped ZnB2O4 phosphor

    International Nuclear Information System (INIS)

    Annalakshmi, O.; Jose, M.T.; Madhusoodanan, U.; Subramanian, J.; Venkatraman, B.; Amarendra, G.; Mandal, A.B.

    2014-01-01

    Polycrystalline powder samples of rare earth doped Zinc borates were synthesized by high temperature solid state diffusion technique. Dosimetric characteristics of the phosphor like thermoluminescence glow curve, TL emission spectra, dose–response, fading studies, reproducibility and reusability studies were carried out on the synthesized phosphors. Among the different rare earth doped phosphors, thulium doped zinc borate was found to have a higher sensitivity. Hence detailed dosimetric characteristics of this phosphor were carried out. It is observed that the dose–response is linear from 10 mGy to 10 3 Gy in this phosphor. EPR measurements were carried out on unirradiated, gamma irradiated and annealed phosphors to identify the defect centers responsible for thermoluminescence. A TL model is proposed based on the EPR studies in these materials. Kinetic parameters were evaluated for the dosimetric peaks using various methods. The experimental results show that this phosphor can have potential applications in radiation dosimetry applications. -- Highlights: • Polycrystalline powder samples of rare earth doped zinc borates were synthesized. • Thulium was observed to be the most efficient dopant in ZnB 2 O 4 lattice. • TL intensity of the dosimetric peak is around 20 times that of TLD-100. • Based on EPR studies a TL mechanism is proposed in zinc borate. • Deconvolution of the glow curve carried out

  4. Thermoluminescence dosimetric characteristics of thulium doped ZnB{sub 2}O{sub 4} phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Annalakshmi, O. [Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Jose, M.T., E-mail: mtj@igcar.gov.in [Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Madhusoodanan, U. [Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Subramanian, J. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai (India); Venkatraman, B. [Radiological Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Amarendra, G. [Materials Physics Division, Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India); Mandal, A.B. [Central Leather Research Institute, Council of Scientific and Industrial Research, Chennai (India)

    2014-02-15

    Polycrystalline powder samples of rare earth doped Zinc borates were synthesized by high temperature solid state diffusion technique. Dosimetric characteristics of the phosphor like thermoluminescence glow curve, TL emission spectra, dose–response, fading studies, reproducibility and reusability studies were carried out on the synthesized phosphors. Among the different rare earth doped phosphors, thulium doped zinc borate was found to have a higher sensitivity. Hence detailed dosimetric characteristics of this phosphor were carried out. It is observed that the dose–response is linear from 10 mGy to 10{sup 3} Gy in this phosphor. EPR measurements were carried out on unirradiated, gamma irradiated and annealed phosphors to identify the defect centers responsible for thermoluminescence. A TL model is proposed based on the EPR studies in these materials. Kinetic parameters were evaluated for the dosimetric peaks using various methods. The experimental results show that this phosphor can have potential applications in radiation dosimetry applications. -- Highlights: • Polycrystalline powder samples of rare earth doped zinc borates were synthesized. • Thulium was observed to be the most efficient dopant in ZnB{sub 2}O{sub 4} lattice. • TL intensity of the dosimetric peak is around 20 times that of TLD-100. • Based on EPR studies a TL mechanism is proposed in zinc borate. • Deconvolution of the glow curve carried out.

  5. Influence of Al{sub 2}O{sub 3} reflective layer under phosphor layer on luminance and luminous efficiency characteristics in alternating-current plasma display panel

    Energy Technology Data Exchange (ETDEWEB)

    Park, Choon-Sang [School of Electronics Engineering, College of IT Engineering, Kyungpook National University, Daegu (Korea, Republic of); Tae, Heung-Sik, E-mail: hstae@ee.knu.ac.kr [School of Electronics Engineering, College of IT Engineering, Kyungpook National University, Daegu (Korea, Republic of); Jung, Eun Young [Core Technology Lab., Corporate R and D Center, Samsung SDI Company Ltd., Cheonan (Korea, Republic of)

    2013-11-29

    This paper examines the optical and discharge characteristics of alternating-current plasma display panel when adopting the Al{sub 2}O{sub 3} reflective layer. The Al{sub 2}O{sub 3} reflective layer is deposited under the phosphor layer by using the screen-printing method. The resulting changes in the optical and discharge characteristics, including the power consumption, color temperature, luminance, luminous efficiency, scanning electron microscopy image, and reflectance, are then compared for both cases with and without Al{sub 2}O{sub 3} reflective layer. As a result of optimizing the thicknesses between the Al{sub 2}O{sub 3} and phosphor layers, the luminance and luminous efficiency are improved by about 17% and 7%, respectively. - Highlights: • We examine characteristics of plasma display panel when adopting reflective layer. • Al{sub 2}O{sub 3} reflective layer was deposited under the phosphor layer. • Al{sub 2}O{sub 3} reflective layer with flaky shape is very effective in enhancing luminance.

  6. Polarographic determination of indium and thallium iodides in phosphor tablets

    International Nuclear Information System (INIS)

    Babich, G.A.; Dzhurka, G.F.; Kozhushko, G.M.; Kravtsova, K.F.; Magda, V.I.

    1984-01-01

    The technique of polarographic determination of indium and thallium iodides in phosphor tablets without preliminary separation of elements was developed. Mercury-dropping electrode was used as an indicator, and saturated calomel electrode was used as an auxiliary electrode. A recording of reduction currents was performed in the potential interval from -0.25 up to 1.15 V at potential sweep speed of 200 mV/min. Optimum conditions of sample acidic decomposition and polarography were presented. A solution of ethylene diamine (0.5 M), of ammonia (0.25 M) and of potassium chloride (0.05 M) served as a background electrolyte. The suggested technique allows one to determine component contents in tablets with a satisfactory accuracy. A period of one tablet analysis constitutes 1.5 h

  7. Extractants for uranium recovery from wet phosphoric acid

    International Nuclear Information System (INIS)

    Musikas, C.; Benjelloun, N.; Lours, S.

    1982-01-01

    Synergistic mixtures containing phosphine oxide plus one of the acidic extractants: dialkyldithiophosphoric acid, dialkylthiophosphoric acid and dialkylphosphoric acid have been compared with respect to U(VI) and Fe(III) extraction from wet phosphoric acid. Distribution curves slope analysis showed that U(VI) extraction mechanisms are totally different. It has been found that U(VI) is extracted as: UO 2 (H 2 PO 4 )(DEHDTP)(TOPO) ; UO 2 (H 2 PO 4 )(DBTP)(POX) 2 and UO 2 (DEHP)(HDEHP) 2 TOPO in dodecane solutions containing di 2 ethylhexyldithiophosphoric acid (HDEHDTP) or dibutylthiophosphoric acid (HDBTP) or di-2-ethylhexylphosphoric acid (HDEHP) plus a phosphine oxide (TOPO or dihexylmethoxyoctylphosphine oxide (POX 11)). The synergistic mixtures containing HDEHDTP gave the highest U(VI) distribution coefficients. Back extraction with oxalic solutions can be achieved only with the synergistic mixtures containing the acidic thiophosphoric donors

  8. Phosphorous gettering in acidic textured multicrystalline solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Montesdeoca-Santana, A. [Departamento de Fisica Basica, Universidad de La Laguna (ULL), Avenida Astrofisico Francisco Sanchez 2, 38206 La Laguna, S/C de Tenerife (Spain); Fraunhofer Institut fuer Solare Energiesysteme ISE, Laboratory and Servicecenter Gelsenkirchen, Auf der Reihe 2, 45884 Gelsenkirchen (Germany); Jimenez-Rodriguez, E.; Diaz-Herrera, B.; Hernandez-Rodriguez, C. [Departamento de Fisica Basica, Universidad de La Laguna (ULL), Avenida Astrofisico Francisco Sanchez 2, 38206 La Laguna, S/C de Tenerife (Spain); Gonzalez-Diaz, B. [Departamento de Fisica Basica, Universidad de La Laguna (ULL), Avenida Astrofisico Francisco Sanchez 2, 38206 La Laguna, S/C de Tenerife (Spain); Departamento de Energia Fotovoltaica, Instituto Tecnologico y de Energias Renovables. Poligono Industrial de Granadilla s/n, 38600 San Isidro-Granadilla de Abona, S/C de Tenerife (Spain); Rinio, M.; Borchert, D. [Fraunhofer Institut fuer Solare Energiesysteme ISE, Laboratory and Servicecenter Gelsenkirchen, Auf der Reihe 2, 45884 Gelsenkirchen (Germany); Guerrero-Lemus, R. [Departamento de Fisica Basica, Universidad de La Laguna (ULL), Avenida Astrofisico Francisco Sanchez 2, 38206 La Laguna, S/C de Tenerife (Spain); Fundacion de Estudios de Economia Aplicada, Catedra Focus-Abengoa, Jorge Juan 46, 28001 Madrid (Spain)

    2011-03-15

    The influence of phosphorus gettering is studied in this work applied to an acidic textured multicrystalline silicon substrate. The texturization was achieved with an HF/HNO{sub 3} solution leading to nanostructures on the silicon surface. It has been demonstrated in previous works that this textured surface decreases the reflectance on the solar cell and increases the surface area improving the photon collection and enhancing the short circuit current. The present study investigates the effect on the minority carrier lifetime of the phosphorous diffusion when it is carried out on this textured surface. The lifetime is measured by means microwave photoconductance decay and quasi steady state phototoconductance devices. The diffused textured wafers are used to fabricate solar cells and their electrical parameters are analyzed. (copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  9. Effect of frost on phosphorescence for thermographic phosphor thermometry

    Science.gov (United States)

    Kim, Dong; Kim, Mirae; Kim, Kyung Chun

    2017-12-01

    In this study, we analyzed phosphorescence lifetime and its accuracy by growing frost for thermographic phosphor thermometry in a low-temperature environment. Mg4FGeO6:Mn particles were coated on an aluminum plate and excited with a UV-LED to obtain phosphorescence signals. The surface temperature was maintained at  -20, -15, -10 °C, and the phosphorescence signal was acquired as the frost grew for 3700 s. The lifetime was calculated and compared with the calibration curve under no-frost conditions. The error of the measured lifetime was within 0.7% of that in the no-frost conditions. A 2D surface temperature profile of the target plate was successfully obtained with the frost formation.

  10. A process for uranium recovery in phosphoric acid

    International Nuclear Information System (INIS)

    Duarte Neto, J.

    1984-01-01

    Results are presented about studies carried out envisaging the development of a process for uranium recovery from phosphoric acid, produced from the concentrate obtained from phosphorus-uraniferous mineral from Itataia mines (CE, Brazil). This process uses a mixture of DEPA-TOPO as extractant and the extraction cycle involves the following stages: acid pre-treatment; adjustment of the oxidation potential so to ensure that all uranium is hexavalent; extraction of uranium from the acid; screening of the solvent to remove undesirable impurities; uranium re-extraction and precipitation; solvent recovery. A micro-pilot plant for continuous processing was built up. Data collected showed that uranium can be recovered with an yield greater than 99%, thus proving the feasibility of the process and encouraging the construction of a bigger scale plant. (Author) [pt

  11. A simple method for estimation of phosphorous in urine

    International Nuclear Information System (INIS)

    Chaudhary, Seema; Gondane, Sonali; Sawant, Pramilla D.; Rao, D.D.

    2016-01-01

    Following internal contamination of 32 P, it is preferentially eliminated from the body in urine. It is estimated by in-situ precipitation of ammonium molybdo-phosphate (AMP) in urine followed by gross beta counting. The amount of AMP formed in-situ depends on the amount of stable phosphorous (P) present in the urine and hence, it was essential to generate information regarding urinary excretion of stable P. If amount of P excreted is significant then the amount of AMP formed would correspondingly increase leading to absorption of some of the β particles. The present study was taken up for the estimation of daily urinary excretion of P using the phospho-molybdate spectrophotometry method. Few urine samples received from radiation workers were analyzed and based on the observed range of stable P in urine; volume of sample required for 32 P estimation was finalized

  12. Woking Park phosphoric acid fuel cell CHP monitoring

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-09-15

    A phosphoric acid fuel (PC25) delivering up to 200kw of electrical power and commensurate heat was installed in Woking Park UK in late 2006 and has been monitored over a period of one year. The system supplies electric power to a leisure centre and swimming pool via a private wires network. This report gives details of the monitoring and shows a schematic of the system, data on electrical and thermal efficiencies, stack voltage variations and gaseous emissions. Extended monitoring is now taking place to provide a complete picture of the economics and operation of the fuel cell in the developing combined heat and power unit and private wires system. The contractor is Advantica of Loughborough and detailed results of the monitoring are available on the DTI website.

  13. Fabrication and characterization of thin-film phosphor combinatorial libraries

    Science.gov (United States)

    Mordkovich, V. Z.; Jin, Zhengwu; Yamada, Y.; Fukumura, T.; Kawasaki, M.; Koinuma, H.

    2002-05-01

    The laser molecular beam epitaxy method was employed to fabricate thin-film combinatorial libraries of ZnO-based phosphors on different substrates. Fabrication of both pixel libraries, on the example of Fe-doped ZnO, and spread libraries, on the example of Eu-doped ZnO, has been demonstrated. Screening of the Fe-doped ZnO libraries led to the discovery of weak green cathodoluminescence with the maximum efficiency at the Fe content of 0.58 mol %. Screening of the Eu-doped ZnO libraries led to the discovery of unusual reddish-violet cathodoluminescence which is observed in a broad range of Eu concentration. No photoluminescence was registered in either system.

  14. Photoluminescence in Sm3+ doped Ba2P2O7 phosphor prepared by solution combustion method

    Science.gov (United States)

    Ghawade, Sonal P.; Deshmukh, Kavita A.; Dhoble, S. J.; Deshmukh, Abhay D.

    2018-05-01

    In this paper, Sm3+ doped Ba2P2O7 phosphors were synthesized via a Solution combustion method. The crystal structure of the phosphor was characterized by XRD. Orange-red emission was observed from these phosphors under near-ultraviolet (UV) excitation at 404 nm. The luminescence properties of the obtained phosphors were characterized by different techniques. The Ba2P2O7:Sm3+ phosphor can be efficiently excited by near-UV and blue light, and their emission spectrum consists of three emission peaks, at 564, 602, and 646 nm, respectively. Based on the results, the as prepared Ba2P2O7:Sm3+ phosphors are promising orange-red-emitting phosphors exhibit great potential may be applicable as a spectral convertor in c-Si solar cell to enhance the efficiency of solar cell in future.

  15. Biomarker for Glycogen Storage Diseases

    Science.gov (United States)

    2017-07-03

    Fructose Metabolism, Inborn Errors; Glycogen Storage Disease; Glycogen Storage Disease Type I; Glycogen Storage Disease Type II; Glycogen Storage Disease Type III; Glycogen Storage Disease Type IV; Glycogen Storage Disease Type V; Glycogen Storage Disease Type VI; Glycogen Storage Disease Type VII; Glycogen Storage Disease Type VIII

  16. Automatic brightness control algorithms and their effect on fluoroscopic imaging

    International Nuclear Information System (INIS)

    Quinn, P.W.; Gagne, R.M.

    1989-01-01

    This paper reports a computer model used to investigate the effect on dose and image quality of three automatic brightness control (ABC) algorithms used in the imaging of barium during general-purpose fluoroscopy. A model incorporating all aspects of image formation - i.e., x- ray production, phantom attenuation, and energy absorption in the CSI phosphor - was driven according to each ABC algorithm as a function of patient thickness. The energy absorbed in the phosphor was kept constant, while the changes in exposure, integral dose, organ dose, and contrast were monitored

  17. Synthesis of novel Dy3+ activated phosphate phosphors for NUV excited LED

    International Nuclear Information System (INIS)

    Shinde, K.N.; Dhoble, S.J.; Kumar, Animesh

    2011-01-01

    The new trivalent dysprosium activated X 6 AlP 5 O 20 (where X=Sr, Ba, Ca and Mg) phosphors were prepared by the combustion method. The prepared phosphors are characterized by XRD, photoluminescence and SEM techniques. Excited by 350 nm near-ultraviolet (NUV) light, the phosphors show an efficient blue and yellow band emissions, which originates from the 4 F 9/2 → 6 H 15/2 and 4 F 9/2 → 6 H 13/2 transitions of Dy 3+ ion, respectively. The excitation spectra of the phosphors are broadband extending from 340 to 400 nm, which are characteristics of NUV excited LED. The effect of the Dy 3+ concentration on the luminescence properties of X 6 AlP 5 O 20 :Dy 3+ (where X=Sr, Ba, Ca and Mg) phosphors is studied. Ca 6 AlP 5 O 20 phosphors show strong PL emission intensity around 25 times more as compared to Ba 6 AlP 5 O 20 , Sr 6 AlP 5 O 20 and Mg 6 AlP 5 O 20 phosphors. The investigated prepared phosphors are suitable for a NUV excited LED. - Research highlights: → Novel Dy 3+ activated X 6 AlP 5 O 20 (where X=Sr,Ba,Ca and Mg) phosphors were prepared by combustion method which is very low cost and time saving synthesis method. → The excitation spectra of the phosphors are broad band extending from 340 nm to 400 nm, which is characteristics of NUV excited LED. → PL emission spectra show two emissions (485 and 573 nm) and X 6 AlP 5 O 20 :Dy 3+ 0.5 mol% (where X=Sr,Ba,Ca and Mg) phosphors shows strongest PL emission intensity. → SEM analysis indicates that phosphor particles have irregular shape, porous morphology and less than 3-4 μm in size, which is suitable for the solid state lighting (coating purpose).

  18. Boron-Containing Red Light-Emitting Phosphors And Light Sources Incorporating The Same

    Science.gov (United States)

    Srivastava, Alok Mani; Comanzo, Holly Ann; Manivannan, Venkatesan

    2006-03-28

    A boron-containing phosphor comprises a material having a formula of AD1-xEuxB9O16, wherein A is an element selected from the group consisting of Ba, Sr, Ca, Mg, and combinations thereof; D is at least an element selected from the group consisting of rare-earth metals other than europium; and x is in the range from about 0.005 to about 0.5. The phosphor is used in a blend with other phosphors in a light source for generating visible light with a high color rendering index.

  19. Flocculation of suspended matter in a crude wet phosphoric acid (Algeria)

    International Nuclear Information System (INIS)

    Brikci Nigassa, M.; Bensebaa, A.

    1994-11-01

    Prior to the recovery of uranium, a pre-treatment of the phosphoric acid is necessary to remove soluble impurities of different origins. In this work, synthetic flocculants have been used. the influence of operating conditions on flocculation and filtration, such as, type of flocculants, polymer concentration, temperature, mixing and time of agitation, has been studied for both aged and fresh phosphoric acid. It has been shown that synthetic flocculants can be used for flocculation ins a phosphoric acid medium and that flocculation and filtration processes are strongly linked

  20. Method for separating mono- and di-octylphenyl phosphoric acid esters

    International Nuclear Information System (INIS)

    Arnold, W.D. Jr.

    1977-01-01

    A method for separating mono-octylphenyl phosphoric acid ester and di-octylphenyl phosphoric acid ester from a mixture thereof comprises reacting the ester mixture with a source of lithium or sodium ions to form a mixture of the phosphate salts; contacting the salt mixture with an organic solvent which causes the dioctylphenyl phosphate salt to be dissolved in the organic solvent phase and the mono-octylphenyl phosphate salt to exist in a solid phase; separating the phases; recovering the phosphate salts from their respective phases; and acidifying the recovered salts to form the original phosphoric acid esters

  1. Extraction of uranium from phosphoric-hydrobromic acid mixture by N-lauryl tri alkyl methylamine

    Energy Technology Data Exchange (ETDEWEB)

    Guirguis, L A [Nuclear materials authority, Cairo, (Egypt); Tadros, N A [Hot laboratories center, atomic energy authority, Cairo, (Egypt)

    1995-10-01

    A uranium recovery process from phosphoric acid produced by the dihydrate method was elaborated. Decomposition of phosphate rock containing 0.02% U is carried out with sulphuric acid. Crude phosphoric acid is filtered off, steam concentrated to 45% P{sub 2} O{sub 5} (6.27 M) and then clarified with activated clay and carbon. The clear phosphoric acid is introduced to uranium extraction after the addition of 0.88 M hydrobromic acid by 0.134 M amberlite LA.2 and 5% decanol, as a modifier, in kerosene. While 10% ammonium sulphate solution is used for stripping. Over 90% uranium recovery is obtained. 6 figs., 1 tab.

  2. Combination of carbon dot and polymer dot phosphors for white light-emitting diodes.

    Science.gov (United States)

    Sun, Chun; Zhang, Yu; Sun, Kai; Reckmeier, Claas; Zhang, Tieqiang; Zhang, XiaoYu; Zhao, Jun; Wu, Changfeng; Yu, William W; Rogach, Andrey L

    2015-07-28

    We realized white light-emitting diodes with high color rendering index (85-96) and widely variable color temperatures (2805-7786 K) by combining three phosphors based on carbon dots and polymer dots, whose solid-state photoluminescence self-quenching was efficiently suppressed within a polyvinyl pyrrolidone matrix. All three phosphors exhibited dominant absorption in the UV spectral region, which ensured the weak reabsorption and no energy transfer crosstalk. The WLEDs showed excellent color stability against the increasing current because of the similar response of the tricolor phosphors to the UV light variation.

  3. Thermally stimulated properties in ZnSe:Tb and ZnSe:(Mn, Tb) phosphors

    Science.gov (United States)

    Mishra, A. K.; Mishra, S. K.; Pandey, S. P.; Lakshmi Mishra, Kshama

    2018-02-01

    Thermoluminescence studies were performed of ZnSe:Tb and ZnSe:(Mn, Tb) phosphors. A method of preparation for ZnSe phosphors doped with Tb and (Mn, Tb) has been discussed. The thermoluminescence (TL) properties of these phosphors have been studied from 100 to 370 K temperature after exciting by UV radiation (365 nm) at three uniform heating rates 0.4, 0.6 and 0.9 K/s. The trapping parameters like trap depth, lifetime of electrons and capture cross-section have also been determined using various methods.

  4. Effect of temperature during UV and gamma irradiations of TL phosphor CaSO4:Dy

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Pendurkar, H.K.

    1979-01-01

    Temperature is an important parameter in thermoluminescence studies. Irradiation at enhanced temperatures reduces the γ response of TL phosphor CaSO 4 :Dy. However, in the presence of fluorescent lights, the γ response of the phosphor is enhanced by approximately 20% for temperatures around 60-100 0 C. If the phosphor temperature during UV exposure is kept high, the integrated TL output continues to increase until it reaches 18 times at 160 0 C as compared to that produced by UV exposure at room temperature. (Auth.)

  5. Use of secondary phosphorescence for determination of the dose absorbed in dosimetric phosphors

    CERN Document Server

    Yaek, I V

    2002-01-01

    The measuring method of optically stimulated persistence (OSP) based on both the time division of the stimulating irradiation and luminescent response registration was applied for the radiation dosimetry. It was shown that the stimulation by the short-wave radiation crossing with spectrum of the dosimetric phosphor is possible. The spectrum of the stimulation of industry dosimetric phosphors was measured. The characteristics of the OSP registration for the phosphors which has manganese Mn sup 2 sup + as the activator is considered. Decay time of inner center luminescence is 40-50 ms. This method is used for the dosimetry of the natural quartzes to determine their age.

  6. Semitechnical studies of uranium recovery from wet process phosphoric acid by liquid-liquid-extraction method

    International Nuclear Information System (INIS)

    Poczynajlo, A.; Wlodarski, R.; Giers, M.

    1987-01-01

    A semitechnical installation for uranium recovery from wet process phosphoric acid has been built. The installation is based on technological process comprising 2 extraction cycles, the first with a mixture of mono- and dinonylphenylphosphoric acids (NPPA) and the second with a synergic mixture of di-/2-ethylhexyl/-phosphoric acid (D2EHPA) and trioctylphosphine oxide (TOPO). The installation was set going and the studies on the concentration distributions of uranium and other components of phosphoric acid have been performed for all technological circuits. 23 refs., 15 figs., 3 tabs. (author)

  7. Study on the relationship between uranium and phosphor in deposit No.60

    International Nuclear Information System (INIS)

    Zhang Wanliang

    1997-01-01

    The deposit No.60 is a large uranium-phosphor one located at the eastern margin of the volcanic basin No.65, and controlled by the stratigraphic horizon of the middle-lower part of the third member of the Ehuling Formation composed of volcaniclastic and terrigeneous classic rocks. Uranium and phosphor were preliminarily concentrated together during the formation of ore-hosting layer, and then reactivated, transported and reprecipitated together under the action of tectonothermal process, leading to the concentration of uranium in cellophane in the adsorption state. Uranium and phosphor are closely associated with the correlation coefficient of up to 0.8-0.9

  8. Case of possible multiple system atrophy with a characteristic imaging finding of open bladder neck during storage phase as an initial sign.

    Science.gov (United States)

    Zhang, Lu; Haga, Nobuhiro; Ogawa, Soichiro; Matsuoka, Kanako; Koguchi, Tomoyuki; Akaihata, Hidenori; Hata, Junya; Kataoka, Masao; Ishibashi, Kei; Kojima, Yoshiyuki

    2017-11-01

    Multiple system atrophy is a neurodegenerative disease that affects autonomic and motor systems. Patients with multiple system atrophy usually experience lower urinary tract symptoms, which sometimes appear as an initial symptom before the emergence of the generalized symptoms. An open bladder neck during the filling phase on video urodynamic study is one characteristic imaging finding after the diagnosis of multiple system atrophy, but has not previously been reported at an early phase of the disease. We report a case in which an open bladder neck was observed on several imaging modalities before generalized symptoms emerged. Because occult neurogenic bladder might exist in patients whose lower urinary tract symptoms are resistant to pharmacotherapy, we report this case to raise awareness of the importance of sufficient imaging evaluations. An open bladder neck might be an important imaging finding for diagnosing multiple system atrophy, irrespective of the presence of generalized symptoms. This finding could help avoid false diagnosis and unnecessary treatment. © 2017 The Japanese Urological Association.

  9. Processing of medical images

    International Nuclear Information System (INIS)

    Restrepo, A.

    1998-01-01

    Thanks to the innovations in the technology for the processing of medical images, to the high development of better and cheaper computers, and, additionally, to the advances in the systems of communications of medical images, the acquisition, storage and handling of digital images has acquired great importance in all the branches of the medicine. It is sought in this article to introduce some fundamental ideas of prosecution of digital images that include such aspects as their representation, storage, improvement, visualization and understanding

  10. Spectrophotometric Analysis of Phosphoric Acid Leakage in High-Temperature Phosphoric Acid-Doped Polybenzimidazole Membrane Fuel Cell Application

    Directory of Open Access Journals (Sweden)

    Seungyoon Han

    2016-01-01

    Full Text Available High-temperature proton exchange membrane fuel cells (HT-PEMFCs utilize a phosphoric acid- (PA- doped polybenzimidazole (PBI membrane as a polymer electrolyte. The PA concentration in the membrane can affect fuel cell performance, as a significant amount of PA can leak from the membrane electrode assembly (MEA by dissolution in discharged water, which is a byproduct of cell operation. Spectrophotometric analysis of PA leakage in PA-doped polybenzimidazole membrane fuel cells is described here. This spectrophotometric analysis is based on measurement of absorption of an ion pair formed by phosphomolybdic anions and the cationoid color reagent. Different color reagents were tested based on PA detection sensitivity, stability of the formed color, and accuracy with respect to the amount of PA measured. This method allows for nondestructive analysis and monitoring of PA leakage during HT-PEMFCs operation.

  11. Encrypted Data Storage in EGEE

    CERN Document Server

    Frohner, Ákos

    2006-01-01

    The medical community is routinely using clinical images and associated medical data for diagnosis, intervention planning and therapy follow-up. Medical imaging is producing an increasing number of digital images for which computerized archiving, processing and analysis are needed. Grids are promising infrastructures for managing and analyzing the huge medical databases. Given the sensitive nature of medical images, practiotionners are often reluctant to use distributed systems though. Security if often implemented by isolating the imaging network from the outside world inside hospitals. Given the wide scale distribution of grid infrastructures and their multiple administrative entities, the level of security for manipulating medical data should be particularly high. In this presentation we describe the architecture of a solution, the gLite Encrypted Data Storage (EDS), which was developed in the framework of Enabling Grids for E-sciencE (EGEE), a project of the European Commission (contract number INFSO--508...

  12. Invariable optical properties of phosphor-free white light-emitting diode under electrical stress

    International Nuclear Information System (INIS)

    Hao, Long; Hao, Fang; Sheng-Li, Qi; Li-Wen, Sang; Wen-Yu, Cao; Jian, Yan; Jun-Jing, Deng; Zhi-Jian, Yang; Guo-Yi, Zhang

    2010-01-01

    This paper reports that a dual-wavelength white light-emitting diode is fabricated by using a metal-organic chemical vapor deposition method. Through a 200-hours' current stress, the reverse leakage current of this light-emitting diode increases with the aging time, but the optical properties remained unchanged despite the enhanced reverse leakage current. Transmission electron microscopy and cathodeluminescence images show that indium atoms were assembled in and around V-shape pits with various compositions, which can be ascribed to the emitted white light. Evolution of cathodeluminescence intensities under electron irradiation is also performed. Combining cathodeluminescence intensities under electron irradiation and above results, the increase of leakage channels and crystalline quality degradation are realized. Although leakage channels increase with aging, potential fluctuation caused by indium aggregation can effectively avoid the impact of leakage channels. Indium aggregation can be attributed to the mechanism of preventing optical degradation in phosphor-free white light-emitting diode. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  13. Phosphoric acid pretreatment of Achyranthes aspera and Sida acuta weed biomass to improve enzymatic hydrolysis.

    Science.gov (United States)

    Siripong, Premjet; Duangporn, Premjet; Takata, Eri; Tsutsumi, Yuji

    2016-03-01

    Achyranthes aspera and Sida acuta, two types of weed biomass are abundant and waste in Thailand. We focus on them as novel feedstock for bio-ethanol production because they contain high-cellulose content (45.9% and 46.9%, respectively) and unutilized material. Phosphoric acid (70%, 75%, and 80%) was employed for the pretreatment to improve by enzymatic hydrolysis. The pretreatment process removed most of the xylan and a part of the lignin from the weeds, while most of the glucan remained. The cellulose conversion to glucose was greater for pretreated A. aspera (86.2 ± 0.3%) than that of the pretreated S. acuta (82.2 ± 1.1%). Thus, the removal of hemicellulose significantly affected the efficiency of the enzymatic hydrolysis. The scanning electron microscopy images showed the exposed fibrous cellulose on the cell wall surface, and this substantial change of the surface structure contributed to improving the enzyme accessibility. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Solvothermally synthesized europium-doped CdS nanorods: applications as phosphors

    International Nuclear Information System (INIS)

    Kumar, Sunil; Jindal, Zinki; Kumari, Nitu; Verma, Narendra Kumar

    2011-01-01

    To exploit the photoluminescent behavior of CdS at nanoscale with different doping concentration of europium—a rare earth element, we report the synthesis of Eu-doped CdS nanorods by using low temperature solvothermal process by using ethylenediamine. The outcomes can have future applications as phosphors, photovoltaic cells, lasers, light emitting diodes, bio-imaging, and sensors. The doping was confirmed by electron dispersive spectroscopy supported by X-ray diffraction. From scanning electron microscopy and transmission electron microscopy analysis it was observed that the average diameter of the Cd 1−x Eu x S nanorods is about 10–12 nm having lengths in the range of 50–100 nm. UV–Visible spectroscopy study was carried out to determine the band gap of the nanorods and the absorbance peaks showed blue shift with respect to the bulk CdS. The blue shift was also observed as the doping concentration of Eu increases. From photoluminescence (PL) studies at λ ex = 450 nm, peaks at 528 and 540 nm were observed due to CdS, peak at 570 nm is due to defects related transitions, while the peak at 613 nm is due to Eu. As the doping concentration of Eu is increased the intensity of the luminescent peak at 613 nm is increased. Thermogravimetric analysis showed the nanorods are thermally stable up to 300 °C. The traces of impurities adsorbed on the nanorods were confirmed by Fourier transform infrared spectroscopy.

  15. Integrating photo-stimulable phosphor plates into dental and dental hygiene radiography curricula.

    Science.gov (United States)

    Tax, Cara L; Robb, Christine L; Brillant, Martha G S; Doucette, Heather J

    2013-11-01

    It is not known whether the integration of photo-stimulable phosphor (PSP) plates into dental and dental hygiene curricula creates unique learning challenges for students. The purpose of this two-year study was to determine if dental hygiene students had more and/or different types of errors when using PSP plates compared to film and whether the PSP imaging plates had any particular characteristics that needed to be addressed in the learning process. Fifty-nine first-year dental hygiene students at one Canadian dental school were randomly assigned to two groups (PSP or film) before exposing their initial full mouth series on a teaching manikin using the parallel technique. The principal investigator determined the number and types of errors based on a specific set of performance criteria. The two groups (PSP vs. film) were compared for total number and type of errors made. Results of the study indicated the difference in the total number of errors made using PSP or film was not statistically significant; however, there was a difference in the types of errors made, with the PSP group having more horizontal errors than the film group. In addition, the study identified a number of unique characteristics of the PSP plates that required special consideration for teaching this technology.

  16. Diagnostic accuracy of phosphor plate systems and conventional radiography in the detection of simulated internal root resorption.

    Science.gov (United States)

    Vasconcelos, Karla de Faria; Rovaris, Karla; Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Távora, Débora de Melo; Bóscolo, Frab Norberto

    2017-11-01

    To evaluate the performance of conventional radiography and photostimulable phosphor (PSP) plate in the detection of simulated internal root resorption (IRR) lesions in early stages. Twenty single-rooted teeth were X-rayed before and after having a simulated IRR early lesion. Three imaging systems were used: Kodak InSight dental film and two PSPs digital systems, Digora Optime and VistaScan. The digital images were displayed on a 20.1″ LCD monitor using the native software of each system, and the conventional radiographs were evaluated on a masked light box. Two radiologists were asked to indicate the presence or absence of IRR and, after two weeks, all images were re-evaluated. Cohen's kappa coefficient was calculated to assess intra- and interobserver agreement. The three imaging systems were compared using the Kruskal-Wallis test. For interexaminer agreement, overall kappa values were 0.70, 0.65 and 0.70 for conventional film, Digora Optima and VistaScan, respectively. Both the conventional and digital radiography presented low sensitivity, specificity, accuracy, positive and negative predictive values with no significant difference between imaging systems (p = .0725). The performance of conventional and PSP was similar in the detection of simulated IRR lesions in early stages with low accuracy.

  17. Recent developments in detectors/phantoms for dosimetry, X-ray quality assurance and imaging

    International Nuclear Information System (INIS)

    Sankaran, A.

    2009-01-01

    During the past years, many new developments have taken place in detectors/phantoms for high energy photon and electron dosimetry (for radiotherapy), protection monitoring, X-ray quality assurance and X-ray imaging (for radiodiagnosis). A variety of detectors and systems, quality assurance (QA) gadgets and special phantoms have been developed for diverse applications. This paper discusses the important developments with some of which the author was actively associated in the past. For dosimetry and QA of 60 Co and high energy X-ray units, state-of-the-art radiation field analyzers, matrix ion chambers, MOSFET devices and Gafchromic films are described. OSL detectors find wide use in radiotherapy dosimetry and provide a good alternative for personnel monitoring. New systems introduced for QA/dosimetry of X-ray units and CT scanners include: multi-function instruments for simultaneous measurement of kVp, dose, time, X-ray waveform and HVT on diagnostic X-ray units; pencil chamber with head and body phantoms for CTDI check on CT scanners. Examples of phantoms used for dosimetry and imaging are given. Advancements in the field of diagnostic X-ray imaging (with applications in portal imaging/dosimetry of megavoltage X-ray units) have led to emergence of: film-replacement systems employing CCD-scintillator arrays, computed radiography (CR) using storage phosphor plate; digital radiography (DR), using a pixel-matrix of amorphous selenium, or amorphous silicon diode coupled to scintillator. All these provide (a) in radiotherapy, accurate dose delivery to tumour, saving the surrounding tissues and (b) in radiodiagnosis, superior image quality with low patient exposure. Lastly, iPODs and flash drives are utilized for storage of gigabyte-size images encountered in medical and allied fields. Although oriented towards medical applications, some of these have been of great utility in other fields, such as industrial radiography as well as a host of other research areas. (author)

  18. Impact of digital imaging on radiation doses to the patient during X-ray examination of the urinary tract.

    Science.gov (United States)

    Sjöholm, B; Geijer, H; Persliden, J

    2005-10-01

    To compare radiation doses given to patients undergoing IVU (intravenous urography) before and after digitalization of our X-ray department. IVU examinations were monitored with dose area product meters before and after the X-ray department changed to digital techniques. The first step was a change from film-screen to storage phosphor plates, while the second step involved changing to a flat panel detector. Forty-two patients were included for the film-screen situation, 69 when using the storage phosphor plates, and 70 using the flat panel detector. A dose reduction from 41.8 Gycm2 to 31.5 Gycm2 was achieved with the first step when the film-screen system was replaced with storage phosphor plates. A further reduction to 12.1 Gycm2 was achieved using the flat panel detector. The introduction of the flat panel detectors made a considerable dose reduction possible.

  19. Mechanoluminescence and photoluminescence of Pr3+ activated KMgF3 phosphor

    International Nuclear Information System (INIS)

    Dhoble, S.J.; Kher, R.S.; Furetta, C.

    2003-01-01

    A Czochralski method for the preparation of crystalline KMgF 3 : Pr phosphors are reported. Photoluminescence (PL) and mechanoluminescence (ML) characteristics are studied. Photoluminescence of Pr 3+ activated KMgF 3 shows the strong emission of Pr 3+ ions were observed at 498 and 650 nm by excitation of 213 mn. ML of KMgF 3 : Pr 3+ shows two peaks, which have been observed in ML intensity versus time curve. The ML peak shows the recombination of electrons with free radical (anion radical produced by γ-irradiation) released from two type traps during the mechanical pressure applied on KMgF 3 : Pr 3+ phosphor. It has a supra linear ML response with γ-ray exposure and a negligible fading. These properties of phosphor should be suitable in dosimetry of ionization relation using ML technique. Therefore the KMgF 3 : Pr 3+ phosphor proposed for ML dosimetry of ionization radiations. (Author)

  20. Promotion of Crystal Growth on Biomass-based Carbon using Phosphoric Acid Treatments

    Directory of Open Access Journals (Sweden)

    Liwei Yu

    2015-02-01

    Full Text Available The effect of phosphoric acid treatments on graphitic microcrystal growth of biomass-based carbons was investigated using X-ray diffraction, infrared spectroscopy, and Raman spectroscopy. Although biomass-based carbons are believed to be hard to graphitize even after heat treatments well beyond 2000 °C, we found that graphitic microcrystals of biomass-based carbons were significantly promoted by phosphoric acid treatments above 800 °C. Moreover, twisted spindle-like whiskers were formed on the surface of the carbons. This suggests that phosphorus-containing groups turn graphitic microcrystalline domains into graphite during phosphoric acid treatments. In addition, the porous texture of the phosphoric acid-treated carbon has the advantage of micropore development.

  1. Spectral downshifting in MBO{sub 3}:Nd{sup 3+} (M=Y, La) phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Omanwar, S.K.; Sawala, N.S. [Sant Gadge Baba Amravati University, Department of Physics, Amravati, MH (India)

    2017-11-15

    The spectral downshifting (DS) from ultra-violet (UV)/visible (VIS) light to near infra-red (NIR) radiation in Nd{sup 3+} doped YBO{sub 3} and LaBO{sub 3} phosphors is reported. The prepared materials were characterized by X-ray powder diffraction (XRD) and photoluminescence (PL) properties along with time-decay curves were studied which confirmed the spectral DS from VIS to NIR radiation. This can be employed to overcome the spectral mismatch of crystalline silicon (c-Si) solar cell with solar spectrum. The prepared Nd{sup 3+} doped as prepared phosphors provide NIR emission (1052 nm) at excitation of 586 nm where response of c-Si solar cell was optimum. Thus spectral modification by mentioned phosphor can be utilized to improve solar cells performance. Hence these phosphors have potential application for photovoltaic (PV) technology. (orig.)

  2. The chemistry of artificial lighting devices lamps, phosphors and cathode ray tubes

    CERN Document Server

    Ropp, Richard C

    2013-01-01

    Both the early use of artificial lighting and current manufacturing methods concerning incandescent and fluorescent lamps are covered in this book. The protocols for manufacture of fluorescent lamp phosphors and those used in cathode ray tubes are also treated in some detail. This text surveys the amazing, vast array of artificial lighting devices known to date in terms of how they arose and are, or have been used by mankind. A complete description of the formulations and methodology for manufacturing all known phosphors is given. The book will serve as a repository of such phosphor manufacturing methods, including that of cathode ray tube phosphors. Methods of manufacture of lamp parts are also presented, including that of tungsten wire. The original approaches used are described as well as improvements in technology. These will serve as comparative methods for present day manufacture of these components. A history of the lamp industry is presented. Several methods are given which may serve as a source for f...

  3. Luminescence properties of Na2Sr2Al2PO4Cl9:Sm3+ phosphor

    Science.gov (United States)

    Tamboli, Sumedha; Shahare, D. I.; Dhoble, S. J.

    2018-04-01

    A series of Sm3+ ions doped Na2Sr2Al2PO4Cl9 phosphors were synthesized via solid state synthesis method. Photoluminescence (PL) emission spectra were obtained by keeping excitation wavelength at 406 nm. Emission spectra show three emission peaks at 563 nm, 595 nm and 644 nm. The CIE chromaticity diagram shows emission colour of the phosphor in the orange-red region of the visible spectrum, indicating that the phosphor may be useful in preparing orange light-emitting diodes. Na2Sr2Al2PO4Cl9:Sm3+ phosphors were irradiated by γ-rays from a 60Co source and β-rays from a 90Sr source. Their thermoluminescence (TL) glow curves were obtained by Nucleonix 1009I TL reader. TL Trapping parameters such as activation energy of trapped electrons and order of kinetics were obtained by using Chen's peak shape method, Glow curve fitting method and initial rise method.

  4. Evaluation of new and conventional thermoluminescent phosphors for environmental monitoring using automated thermoluminescent dosimeter readers

    International Nuclear Information System (INIS)

    Rathbone, B.A.; Endres, A.W.; Antonio, E.J.

    1994-10-01

    In recent years, there has been considerable interest in a new generation of super-sensitive thermoluminescent (TL) phosphors for potential use in routine personnel and environmental monitoring. Two of these phosphors, α-Al 2 O 3 :C and LiF:Mg,Cu,P, are evaluated in this paper for selected characteristics relevant to environmental monitoring, along with two conventional phosphors widely used in environmental monitoring, LiF:Mg,Ti and CaF 2 :Dy. The characteristics evaluated are light-induced fading, light-induced background, linearity and variability at low dose, and the minimum measurable dose. These characteristics were determined using an automated commercial dosimetry system (Harshaw System 8800) and routine processing protocols. Annealing and readout protocols for each phosphor were optimized for use in a large-scale environmental monitoring program

  5. Structural and spectral properties of MgZnO2:Sm3+ phosphor

    Science.gov (United States)

    Rajput, Preasha; Sharma, Pallavi; Biswas, Pankaj; Kamni

    2018-05-01

    The samarium doped MgZnO2 phosphor was synthesized by the low-cost combustion method. The powder X-ray diffraction (XRD) analysis confirmed the crystallinity and phase purity of the phosphor. The lattice parameters were determined by indexing the diffraction peaks. The photoluminescence (PL) study revealed that the phosphor exhibited a broad excitation band in the UV region ranging between 200 to 350 nm. The 601 nm emission was ascribed to 4G5/2 to 6H7/2 transitions of the Sm3+ ion. The optical bandgap of MgZnO2:Sm3+ was obtained to be 3.56 eV. The phosphor can be projected as a useful material in X- and gamma-ray scintillators.

  6. Luminescence properties of terbium-doped Li3PO4 phosphor for ...

    Indian Academy of Sciences (India)

    ... of faster and multiple readout, very high sensitivity, absence of thermal quenching and possible use of phosphor in plastic binders [3–15]. ... synthesis technique was developed to reduce the time required for the synthesis, which was about.

  7. Application of a precipitation method for uranium recovery from Abu-Zaabal phosphoric acid plant, egypt

    International Nuclear Information System (INIS)

    El-Hazek, N.M.T.; Hussein, E.M.

    1997-01-01

    Current industrial recovery of uranium from 30% phosphoric acid-produced by the dihydrate process-is based on solvent extraction method. Uranium recovery from concentrated phosphoric acid (45-52% P 2 O 5 ) produced by evaporation of the 30% acid or directly produced by the hemihydrate process, by solvent extraction is difficult to apply in practice. In addition to possible contamination of the acid by the organic solvents and/or their deterioration. This paper investigates the possibility of applying a precipitation method (Weterings and Janssen, 1985) for uranium recovery from both low (28% P 2 O 2 ) and high (48% P 2 O 5 ) concentration phosphoric acids produced by abu-Zaabal phosphoric acid plant (abu-Zaabal fertilizers and chemicals Co., Egypt). The 28% acid produced by H 2 SO 4 dihydrate method and the 48% acid produced by evaporation of the 28% acid

  8. Measurement of thermal neutron fluence with CaSO4 thermoluminescent phosphors

    International Nuclear Information System (INIS)

    Liu Jinhua; Su Jingling; Wei Zemin

    1984-01-01

    During neutron irradiation, some TL phosphors were activated. After leaving the irradiation field the TL phosphor produced self-irradiation. The TL output of self-dose was only related to the original neutron fluence and independent of the γ-radiation. Several CaSO 4 TL phosphors were made. They were CaSO 4 :Dy, CaSO 4 :Dy-Teflon, CaSO 4 :Dy mixed with Dy 2 O 3 , CaSO 4 :Mn mixed with Dy 2 O 3 . The linearity, and lower detection limits of these TL phosphors were measured. The thermal neutron response of CaSO 4 :Mn mixed with Dy 2 O 3 was 64 R/(10 10 cm -2 ) and the lower detection limit was 1.3x10 5 cm -2

  9. Co-doping with antimony to control phosphorous diffusion in germanium

    KAUST Repository

    Tahini, H. A.; Chroneos, Alexander; Grimes, R. W.; Schwingenschlö gl, Udo

    2013-01-01

    donor co-doping on the migration activation energies of vacancy-mediated diffusion processes. The migration energy barriers for phosphorous and antimony were found to be increased significantly when larger clusters involving two donor atoms and a vacancy

  10. SiO{sub 2} effect on spectral and colorimetric properties of europium doped SrO{sub 2}-MgO-xSiO{sub 2} (0.8 {<=} x {<=} 1.6) phosphor for white LEDs

    Energy Technology Data Exchange (ETDEWEB)

    Chen, B J; Jang, K W; Lee, H S; Jayasimhadri, M; Cho, E J [Department of Physics, Changwon National University, Changwon, 641-773 (Korea, Republic of); Yi, S S [Department of Photonics, Silla University, Pusan 617-736 (Korea, Republic of); Jeong, J H [Department of Physics, Pukyong National University, Pusan 608-737 (Korea, Republic of)], E-mail: kwjang@changwon.ac.kr

    2009-05-21

    Silicate phosphors with compositions 1.99 SrO{sub 2}-1.0 MgO-xSiO{sub 2}-0.01 Eu{sub 2}O{sub 3} (x = 0.8, 1.0, 1.2, 1.4 and 1.6) were prepared in a reducing atmosphere via a solid state reaction. The resultant phosphors were examined by using x-ray diffraction and confirmed to be a mixture of monoclinic Sr{sub 2}SiO{sub 4} and orthorhombic Mg{sub 2}(Si{sub 2}O{sub 4}). The scanning electron microscope images revealed that SiO{sub 2} content does not influence the morphology of the resultant phosphors. It was also observed that the excitation spectra are dependent on the monitored emission wavelength, and the emission spectra are dependent on the excitation wavelength and the SiO{sub 2} content. The energy transfer between Eu{sup 2+} ions occupying different Sr{sup 2+} sites was discussed. The colour coordinates for these phosphors are tunable based on both the excitation wavelength and the SiO{sub 2} content.

  11. Luminescence properties of dysprosium doped calcium magnesium silicate phosphor by solid state reaction method

    Energy Technology Data Exchange (ETDEWEB)

    Sahu, Ishwar Prasad, E-mail: ishwarprasad1986@gmail.com [School of Studies in Physics & Astrophysics, Pt. Ravishankar Shukla University, Raipur, C.G. 492010 (India); Chandrakar, Priya; Baghel, R.N.; Bisen, D.P.; Brahme, Nameeta [School of Studies in Physics & Astrophysics, Pt. Ravishankar Shukla University, Raipur, C.G. 492010 (India); Tamrakar, Raunak Kumar [Department of Applied Physics, Bhilai Institute of Technology, Durg, C.G. 491001 (India)

    2015-11-15

    Dysprosium doped calcium magnesium silicate (CaMgSi{sub 2}O{sub 6}:Dy{sup 3+}) white light emitting phosphor was synthesized by solid state reaction process. The crystal structure of sintered phosphor was monoclinic structure with space group C2/c. Chemical composition of the sintered CaMgSi{sub 2}O{sub 6}:Dy{sup 3+} phosphor was confirmed by EDX. The prepared CaMgSi{sub 2}O{sub 6}:Dy{sup 3+} phosphor was excited from 352 nm and their corresponding emission spectra were recorded at blue (470 nm), yellow (570 nm) and red (675 nm) line due to the {sup 4}F{sub 9/2} → {sup 6}H{sub 15/2}, {sup 4}F{sub 9/2} → {sup 6}H{sub 13/2}, {sup 4}F{sub 9/2} → {sup 6}H{sub 11/2} transitions of Dy{sup 3+} ions. The combination of these three emissions constituted as white light confirmed by the Commission Internationale de L'Eclairage (CIE) chromatic coordinate diagram. The possible mechanism of the white light emitting long lasting CaMgSi{sub 2}O{sub 6}:Dy{sup 3+} phosphor was also investigated. Investigation on afterglow property show that phosphor held fast and slow decay process. The peak of mechanoluminescence (ML) intensity increases linearly with increasing impact velocity of the moving piston. Thus the present investigation indicates that the local piezoelectricity-induced electron bombardment model is responsible to produce ML in prepared CaMgSi{sub 2}O{sub 6}:Dy{sup 3+} phosphor. - Highlights: • The crystal structure of CaMgSi{sub 2}O{sub 6}:Dy{sup 3+} phosphor is consistent with standard monoclinic structure. • CIE coordinates of CaMgSi{sub 2}O{sub 6}:Dy{sup 3+} phosphor is suitable as white light emitting phosphor. • The local piezoelectricity-induced electron bombardment model is responsible to produce ML in CaMgSi{sub 2}O{sub 6}:Dy{sup 3+} phosphor.

  12. Investigation of the effect of engine lubricant oil on remote temperature sensing using thermographic phosphors

    Energy Technology Data Exchange (ETDEWEB)

    Abou Nada, Fahed, E-mail: Fahed.Abou_Nada@forbrf.lth.se; Aldén, Marcus; Richter, Mattias

    2016-11-15

    Phosphor thermometry, a remote temperature sensing technique, is widely implemented to measure the temperature of different combustion engines components. The presence of engine lubricant can influence the behavior of the applied sensor materials, known as thermographic phosphors, and thus leading to erroneous temperature measurements. The effect of two engine lubricants on decay times originating from six different thermographic phosphors was investigated. The decay time of each thermographic phosphor was investigated as a function of lubricant/phosphor mass ratio. Tests were conducted at temperatures around 293 K and 376 K for both lubricants. The investigations revealed that ZnO:Zn and ZnS:Ag are the only ones that exhibit a change of the decay time as function of the lubricant/phosphor mass ratio. While the remaining thermographic phosphors, namely BaMg{sub 2}Al{sub 16}O{sub 27}:Eu (BAM), Al{sub 2}O{sub 3}-coated BaMg{sub 2}Al{sub 16}O{sub 27}:Eu, La{sub 2}O{sub 2}S:Eu, Mg{sub 3}F{sub 2}GeO{sub 4}:Mn, displayed no sensitivity of their characteristic decay time on to the presence of lubricant on the porous coating. Biases in the calculated temperature are to be expected if the utilized thermographic phosphor displays decay time sensitivity to the existence of the engine lubricant within the sensor. Such distortions are concealed and can occur undetected leading to false temperature readings for the probed engine component.

  13. Oxidation-extraction of uranium from wet-process phosphoric acid

    International Nuclear Information System (INIS)

    Lawes, B.C.

    1985-01-01

    The invention involves an improvement to the reductive stripping process for recovering uranium values from wet-process phosphoric acid solution, where uranium in the solution is oxidized to uranium (VI) oxidation state and then extracted from the solution by contact with a water immiscible organic solvent, by adding sufficient oxidant, hydrogen peroxide, to obtain greater than 90 percent conversion of the uranium to the uranium (VI) oxidation state to the phosphoric acid solution and simultaneously extracting the uranium (VI)

  14. Determination of formal potential of Amsup((4))/Amsup((3)) pair in phosphoric-acid solutions

    International Nuclear Information System (INIS)

    Mikhajlov, V.M.; Myasoedov, B.F.

    1977-01-01

    Values of formal potentials of the system Amsup((4))/Amsup((3)) in 12 and 15 M phosphoric acid at 20+-2 deg C are determined by potentiometric method. The effect is studied of metallic platinum on the process of self-reduction of tetravalent americium, and the optimum conditions are found for potentiostatic oxidation of Amsup((3)) to Amsup((4)) in 12 M phosphoric acid

  15. Photoluminescence and absorption spectra of various common TL phosphors - interpretation of TL mechanisms

    International Nuclear Information System (INIS)

    Nagpal, J.S.

    1980-01-01

    Photoluminescence and absorption spectra of TL phosphors TLD-100, CaF 2 :Dy, CaSO 4 :Dy(0.05%wt), CaSO 4 :Tm(0.05%wt) and Mg 2 SiO 4 :Tb have been measured. The absorption spectra are typical of RE 2+ in rare earth doped irradiated phosphors. On heating RE 2+ yields RE 3+ and emission from the excited states of RE 3+ is observed. (author)

  16. UV, blue and red upconversion emission in Tm3+ doped Y2O3 phosphor

    International Nuclear Information System (INIS)

    Pandey, Anurag; Kaushal Kumar; Rai, Vineet Kumar

    2012-01-01

    Optimized solution combustion route has been adopted to prepare Tm 3+ doped Y 2 O 3 phosphor. The X-ray diffraction analysis of the doped phosphor for getting the structural information has been performed. Intense UV, blue and red emissions exhibiting narrow band have been monitored using 980 nm diode laser excitation. The origin of UV, blue and red upconversion emissions has been explained based on the available data. (author)

  17. The use of ion chromatography for the determination of impurities in crude phosphoric acid

    International Nuclear Information System (INIS)

    Pires, M.A.F.; Atalla, L.T.; Abrao, A.

    1988-07-01

    The determination of fluoride, nitrate, sulphate and phosphate ions in crude phosphoric acid by means of ion chromatography is described. A previous separation of interferent cations was made by using a cationic resin or EDTA complexation. The last alternative allowed more reproductible results. The technique described is very quick and is being applied for the simultaneous determination of impurities in phosphoric acid and its own phosphospate concentration. The method is quick and has good reprodutibility. (author) [pt

  18. Mass storage technology in networks

    Science.gov (United States)

    Ishii, Katsunori; Takeda, Toru; Itao, Kiyoshi; Kaneko, Reizo

    1990-08-01

    Trends and features of mass storage subsystems in network are surveyed and their key technologies spotlighted. Storage subsystems are becoming increasingly important in new network systems in which communications and data processing are systematically combined. These systems require a new class of high-performance mass-information storage in order to effectively utilize their processing power. The requirements of high transfer rates, high transactional rates and large storage capacities, coupled with high functionality, fault tolerance and flexibility in configuration, are major challenges in storage subsystems. Recent progress in optical disk technology has resulted in improved performance of on-line external memories to optical disk drives, which are competing with mid-range magnetic disks. Optical disks are more effective than magnetic disks in using low-traffic random-access file storing multimedia data that requires large capacity, such as in archive use and in information distribution use by ROM disks. Finally, it demonstrates image coded document file servers for local area network use that employ 130mm rewritable magneto-optical disk subsystems.

  19. Archival storage solutions for PACS

    Science.gov (United States)

    Chunn, Timothy

    1997-05-01

    While they are many, one of the inhibitors to the wide spread diffusion of PACS systems has been robust, cost effective digital archive storage solutions. Moreover, an automated Nearline solution is key to a central, sharable data repository, enabling many applications such as PACS, telemedicine and teleradiology, and information warehousing and data mining for research such as patient outcome analysis. Selecting the right solution depends on a number of factors: capacity requirements, write and retrieval performance requirements, scaleability in capacity and performance, configuration architecture and flexibility, subsystem availability and reliability, security requirements, system cost, achievable benefits and cost savings, investment protection, strategic fit and more.This paper addresses many of these issues. It compares and positions optical disk and magnetic tape technologies, which are the predominant archive mediums today. Price and performance comparisons will be made at different archive capacities, plus the effect of file size on storage system throughput will be analyzed. The concept of automated migration of images from high performance, high cost storage devices to high capacity, low cost storage devices will be introduced as a viable way to minimize overall storage costs for an archive. The concept of access density will also be introduced and applied to the selection of the most cost effective archive solution.

  20. Transformation invariant image indexing and retrieval for image databases

    NARCIS (Netherlands)

    Gevers, Th.; Smeulders, A.W.M.

    1994-01-01

    This paper presents a novel design of an image database system which supports storage, indexing and retrieval of images by content. The image retrieval methodology is based on the observation that images can be discriminated by the presence of image objects and their spatial relations. Images in the