WorldWideScience

Sample records for stones radiographic examinations

  1. A radiographic examination system

    International Nuclear Information System (INIS)

    Cable, A.P.; Cable, W.S.

    1983-01-01

    A system for performing radiographic examination, particularly of large items such as international container units is disclosed. The system is formed as an installation comprising housings for respective linear accelerators transmitting a beam of radiation across the path of a conveyor along which the units can be displaced continuously or incrementally. On either end of the installation are container handling areas including roller conveyors with drag chains and transverse manipulators, and the whole installation is secured within automatically operated doors which seal the high energy region when a container on the conveyor is being subjected to examination. The radiation transmitted through a container is detected in a detector system incorporating a fluoroscopic screen light output from which is detected in a camera system such as a television camera, and transmitted as coded pulsed signals by a coding transfer unit to display screens where an image of the transmitted information can be displayed and/or recorded for further use. (author)

  2. Radiographic examination of the equine foot

    International Nuclear Information System (INIS)

    Park, R.D.

    1989-01-01

    A complete radiographic examination of the equine foot consists of properly exposed, processed, and positioned radiographs. For radiographic interpretation, in addition to knowing radiographic signs of disease, a knowledge of normal radiographic anatomy and possible insignificant anatomic variations is necessary

  3. Nondestructive examination - radiographic techniques

    International Nuclear Information System (INIS)

    Maier, H.J.

    1980-01-01

    First the basic principles of radiography are to be treated, especially the different radiation sources (X-ray, gamma-ray, neutrons, heat). In the second part those radiographic methods are shown, which are in common use for technical purposes, especially under the aspect of flaw recognition. (orig./RW)

  4. Radiographic examination apparatus

    International Nuclear Information System (INIS)

    Beetham, S.; Hogg, J.

    1983-01-01

    Tube examination apparatus has a head actuated by fluid pressure, for centralising a radioactive source. Preferably the source is shielded during transport from its storage unit to the head. A body attached to a drive-wire has hollow shield-parts which define a radiation window therebetween, and closure shield-parts which have the source located therebetween and which are a sliding fit. A spring biases the closure shields towards a first position relative to the body in which the source is enclosed. When the body moves along a guide in the head, the closure shield engages an abutment surface which arrests the closure shields. Further movement of the body to engage an abutment surface causes relative movement between the shield parts to a second position relative to the body in which the source is exposed at the window. Retraction of the body along the guide allows the spring to restore the closure shield parts to the first position. (U.K.)

  5. Radiographic examination of the equine head

    International Nuclear Information System (INIS)

    Park, R.D.

    1993-01-01

    Radiographic examinations of the equine head can be performed with portable x-ray machines. The views comprising the examination depend on the area of the head being examined. With a knowledge of radiographic anatomy and radiographic signs of disease, valuable diagnostic information can be obtained from the radiographic examination. In addition, the radiographic information can also be used to develop a prognosis and determine the most appropriate therapy

  6. Radiographic examination for successful dental implant

    International Nuclear Information System (INIS)

    Lee, Sam Sun; Choi, Soon Chul

    2005-01-01

    Recently implant has become an important field in dental clinic. Radiographic examination of pre- and post-operation is essential for successful treatment. Clinicians should have knowledge about the purpose of the radiographic examination, suitable imaging modality for the cases, anatomic landmarks of tooth and jaw bone, advantage and limitation of panoramic radiographic examination for implant, principle and interpretation of cross-sectional imaging, bone mineral density, post-operative radiographic examination. This paper will be helpful to get above information for dentists who want to do dental implant successfully.

  7. The radiographic examination of the colon

    International Nuclear Information System (INIS)

    Hendrix, T.R.; Saba, G.P. II.

    1980-01-01

    To provide medical and scientific background on certain selected technologies generally considered to be of particular significance, the National Center for Health Care Technology commissioned a series of overview papers, one of which is entitled 'The Radiographic Examination of the Colon.' These overviews are likely to be of most immediate interest to clinicians and biomedical scientists; they also may provide valuable background for assessments undertaken by the Center and for exploring the broad societal implications of health care technologies. Barium enema is the most available and widely used technique for examining the colon. It is often a routine part of the gastrointestinal work-up regardless of the suspected basis, anatomical or functional, of the patient's symptoms. Indeed, common practice is not to entertain a diagnosis of functional disorder before excluding all reasonable possibility of an anatomical abnormality. Barium enema is one of the most frequently ordered radiographic examinations

  8. RADIOGRAPHIC EXAMINATION OF TEMPOROMANDIBULAR DISORDERS IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Heru Suryonegoro

    2015-06-01

    Full Text Available The temporomandibular joint has a very important role in the stomatognathic system. Its main function is for the opening and closing movement, mastication, and speech. It is located anterior to the ear. The temporomandibular joint connects maxilla and mandible through the articular fossa, hence the slightest change that happens would cause serious matters such as pain, exiting, speech disorder, difficulty in opening and closing movement, headache, and even trismus. In a child or an adolescent, the symptoms are often vague; everything is interpreted as “pain”. This is probably why temporomandibular disorder are often undetected by dentists. Therefore, patience and accuracy is needed to determine the actual disorder through means of clinical and radiographic examination. The radiographic examination suitable for child is the transcranial projection. This projection is believed to be more accurate amongst other projection for child patients.

  9. Incidence and Distribution of Pulp Stones Found in Radiographic ...

    African Journals Online (AJOL)

    or more in a single tooth, their size varying from minute particles to large masses ... between pulp stones and sex, tooth type, dental arch, side and .... attended Kırıkkale University Dental School (KUDS).Caution .... Beside these disadvantages,.

  10. Incidence and Distribution of Pulp Stones Found in Radiographic ...

    African Journals Online (AJOL)

    The overall incidence of pulp stones in the patients and their correlations between female and male patients and between the right‑side and left‑side occurrences were analyzed by computer program, SPSS 15. (SPSS Inc. Chicago, USA) with using the χ2 test. Differences were considered as significant when P < 0.05.

  11. Assessment of Radiographic Image Quality by Visual Examination of Neutron Radiographs of the Calibration Fuel Pin

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Up till now no reliable radiographic image quality standards exist for neutron radiography of nuclear reactor fuel. Under the Euratoro Neutron Radiography Working Group (NRWG) Test Program neutron radiographs were produced at different neutron radiography facilities within the European Community...... of a calibration fuel pin. The radiographs were made by the direct, transfer and tracketch methods using different film recording materials. These neutron radiographs of the calibration fuel pin were used for the assessement of radiographic image quality. This was done by visual examination of the radiographs...

  12. Radiographic examination of the equine stifle

    International Nuclear Information System (INIS)

    Denoix, J.M.

    1986-01-01

    A radiographic technique is described for the equine stifle joint with the horse in the standing position or under general anaesthesia. The method with the animal anaesthetised in the dorsal recumbency and the leg extended was preferred because it gave greater flexibility with a better range of views and greatly reduced the safety hazards. In the standing position a useful practical tip for the lateral view was to raise and extent the limb caudally. This provides some flexion and ventral movement of the stifle allowing improved access for the cassette, a more accurate lateral view of the joint and a reduction in exposure. Some of the features of radiographic anatomy, from birth to adulthood, of this rather complex joint are described to form a basis for radiological interpretation in cases of suspected stifle lameness

  13. Radiographic examination takes on an automated image

    International Nuclear Information System (INIS)

    Aman, J.

    1988-01-01

    Automation can be effectively applied to nondestructive testing (NDT). Until recently, film radiography used in NDT was largely a manual process, involving the shooting of a series of x-rays, manually positioned and manually processed. In other words, much radiographic work is being done the way it was over 50 years ago. Significant advances in automation have changed the face of manufacturing, and industry has shared in the benefits brought by such progress. The handling of parts, which was once responsible for a large measure of labor costs, is now assigned to robotic equipment. In nondestructive testing processes, some progress has been achieved in automation - for example, in real-time imaging systems. However, only recently have truly automated NDT begun to emerge. There are two major reasons to introduce automation into NDT - reliability and productivity. Any process or technique that can improve the reliability of parts testing could easily justify the capital investments required

  14. Do general radiographic examinations resemble a person-centred environment?

    International Nuclear Information System (INIS)

    Hayre, C.M.; Blackman, S.; Eyden, A.

    2016-01-01

    Aim and objective: It is argued whether general radiographic examinations adhere to a person-centred approach within the direct digital radiography (DDR) environment. General radiographic examinations continue to increase and constitute approximately 90% of all examinations undertaken in the clinical environment. This study explored the potential impact patients experience whilst undergoing general imaging examinations. Method: An ethnographic methodology provided insight of two general radiography environments in the United Kingdom (UK) using participant observation and semi-structured interviews. Findings: The findings highlighted an ‘in and out’ culture whereby patients are ‘hurried’ and ‘rushed’ out of X-ray rooms in response to increasing time pressures experienced by diagnostic radiographers. In addition, this study challenged that patients may begin to rank ‘speed’ and ‘waiting times’ above other elements of radiographic care thus presenting new challenges for radiographers within the clinical environment. Conclusion: It is asserted that radiographers should remain holistic healthcare professionals and not begin to resemble operators on the production line. Further, it challenges whether patients are beginning to rank aspects of radiographic care within contemporary practices. Advances in knowledge: Few studies have explored the radiographer–patient relationship within the DDR environment, yet this study provides insight of person-centred practices within contemporary practices. - Highlights: • Challenges whether the use of DDR conforms to a person-centred approach. • Challenges whether radiographers are ‘treating patients as persons’ using DDR. • Patients may begin to rank ‘speed’ and ‘waiting times’ above other aspects of radiographic care.

  15. Measuring stone surface area from a radiographic image is accurate and reproducible with the help of an imaging program.

    Science.gov (United States)

    Kurien, Abraham; Ganpule, Arvind; Muthu, V; Sabnis, R B; Desai, Mahesh

    2009-01-01

    The surface area of the stone from a radiographic image is one of the more suitable parameters defining stone bulk. The widely accepted method of measuring stone surface area is to count the number of square millimeters enclosed within a tracing of the stone outline on graph paper. This method is time consuming and cumbersome with potential for human error, especially when multiple measurements are needed. The purpose of this study was to evaluate the accuracy, efficiency, and reproducibility of a commercially available imaging program, Adobe Photoshop 7.0 for the measurement of stone surface area. The instructions to calculate area using the software are simple and easy in a Windows-based format. The accuracy of the imaging software was estimated by measuring surface areas of shapes of known mathematical areas. The efficiency and reproducibility were then evaluated from radiographs of 20 persons with radiopaque upper-tract urinary stones. The surface areas of stone images were measured using both graph paper and imaging software. Measurements were repeated after 10 days to assess the reproducibility of the techniques. The time taken to measure the area by the two methods was also assessed separately. The accuracy of the imaging software was estimated to be 98.7%. The correlation coefficient between the two methods was R(2) = 0.97. The mean percentage variation using the imaging software was 0.68%, while it was 6.36% with the graph paper. The mean time taken to measure using the image analyzer and graph paper was 1.9 +/- 0.8 minutes and 4.5 +/- 1.08 minutes, respectively (P stone surface area from radiographs compared with manual measurements using graph paper.

  16. Justification of radiographic examinations: What are the key issues?

    OpenAIRE

    Vom, Jason; Williams, Imelda

    2017-01-01

    Abstract Justification of radiographic examinations is the practice of evaluating requested radiological examinations to assess for clinical merit and appropriateness based on clinical notes and patient information. This implies that justification in radiography requires the evaluation of requested examinations, the justification of exposures being applied and determining whether patients fit the recommended criteria for the procedure. Medico?legal requirements by the professional registratio...

  17. General practitioners' willingness to request plain lumbar spine radiographic examinations

    International Nuclear Information System (INIS)

    Ryynaenen, Olli-Pekka; Lehtovirta, Jukka; Soimakallio, Seppo; Takala, Jorma

    2001-01-01

    Objectives: To examine general practitioners' attitudes to plain lumbar spine radiographic examinations. Design: A postal questionnaire consisting of questions on background data and doctors' opinions about plain lumbar spine radiographic examinations, as well as eight vignettes (imaginary patient cases) presenting indications for lumbar radiography, and five vignettes focusing on the doctors' willingness to request lumbar radiography on the basis of patients' age and duration of symptoms. The data were analysed according to the doctor's age, sex, workplace and the medical school of graduation. Setting: Finland. Subjects: Six hundred and fifteen randomly selected physicians working in primary health care (64% of original target group). Results: The vignettes revealed that the use of plain lumbar radiographic examination varied between 26 and 88%. Patient's age and radiation protection were the most prominent factors influencing doctors' decisions to request lumbar radiographies. Only slight differences were observed between the attitudes of male and female doctors, as well as between young and older doctors. Doctors' willingness to request lumbar radiographies increased with the patient's age in most vignettes. The duration of patients' symptoms had a dramatic effect on the doctor's decision: in all vignettes, doctors were more likely to request lumbar radiography when patient's symptoms had exceeded 4 weeks. Conclusions: General practitioners commonly use plain lumbar spine radiographic examinations, despite its limited value in the diagnosis of low back pain. Further consensus and medical education is needed to clarify the indications for plain lumbar radiographic examination

  18. Justification of radiographic examinations: What are the key issues?

    Science.gov (United States)

    Vom, Jason; Williams, Imelda

    2017-09-01

    Justification of radiographic examinations is the practice of evaluating requested radiological examinations to assess for clinical merit and appropriateness based on clinical notes and patient information. This implies that justification in radiography requires the evaluation of requested examinations, the justification of exposures being applied and determining whether patients fit the recommended criteria for the procedure. Medico-legal requirements by the professional registration body, the Medical Radiation Practice Board of Australia (MRPBA), identify justification as an advocated and obligatory practice for radiographers. Yet, justification remains an inconsistent practice implemented amongst Australian radiographers. This review aims to identify associated barriers inhibiting the consistent practice of justification and the hesitance by radiographers in practicing justification responsibilities. It also recommends a change in workplace culture which encourages radiographers to accept a more autonomous role that cultivates critical thinking, reflection and research-informed decision making as justification will ultimately benefit patients. © 2017 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  19. Coke detection in furnaces tubes by radiographic examination

    International Nuclear Information System (INIS)

    Santos, I.S. dos

    1987-01-01

    The coke detection technique by radiographic examinations allows to quantify the coke in furnace coils of Petroleum refineries and petrochemical industries. The paper describes how was determined the radiographic parameters, the wall apparent thickness calculation, the distance source-film, the position of the source and films, the chosen of films and the calculation of exposure time, aiming to obtain high producticity and good quality image. This technique is being used and improved for more than two years with good results. (E.G.) [pt

  20. Clinical history and physical examination skills - A requirement for radiographers?

    International Nuclear Information System (INIS)

    Snaith, Beverly A.; Lancaster, Anne

    2008-01-01

    Radiographer's roles have evolved with their scope broadening over the last 20 years culminating in the development of advanced and consultant posts. Yet one development has not been embraced, despite being inherent in medicine and a common extension of nurse and other allied health professionals' roles, is that of clinical assessment. This article explores the evolving role of the radiographer and discusses whether this should include skills in clinical history taking and physical examination. Issues for education and development will be addressed together with examples of current and potential roles

  1. Macroscopic and radiographic examination of proximal root surface caries

    International Nuclear Information System (INIS)

    Nordenram, G.; Bergvist, A.; Johnson, G.; Henriksen, C.O.; Anneroth, G.

    1988-01-01

    The purpose of the study was to compare macroscopic and radiographic examination of proximal root surface caries of extracted teeth from patients aged 65-95 years. Although the study conditions for macroscopic and radiographic diagnosis favored more sensitive evaluations than routine clinical conditions, there was a 24% disagreement in diagnosis. This finding indicates that under routine clinical conditions it is difficult to register with certainty all superficial root carious lesions. Even in the absence of clinically detectable root surface caries, preventive measures should be considered for elderly people with exposed root surfaces

  2. Negative radiographic examinations: Evaluation of risks from exposure

    International Nuclear Information System (INIS)

    Frometa Suarez, I.; Jerez Vegueria, S.F.

    1997-01-01

    The individual dose of radiation per radiological diagnosis is decreasing, which is an important contribution for the number of exposed population. This is a result of a completed study presented by the Manuel Fajardo Surgery Clinic of the Municipality of Havana, which evaluated the behaviour of the negative radiological examinations and their contribution to the collective dose as well as the associated detriment. 486 cases with radiographic examinations are reported over a period of four months. The information on individual cases is classified by type of radiographic examination and whether the outcome of the examination was positive or negative, the absorbed doses per organ and irradiated tissue, dose equivalent, collective and effective doses. The probability of the occurrence of a fatal cancer and associated genetic damage due to the examinations is also considered. 41% of the examinations performed were negative, with a collective dose of 11.35 manSv and 52.9 % of the total doses contributed for all the radiological examinations of the population studied

  3. Radiographic examinations of the leopard gecko, Eublepharis macularius

    International Nuclear Information System (INIS)

    Bayer, S.M.

    2002-11-01

    The anatomy of the Leopard gecko, Eublepharis macularius, and the technique and the diagnostic possibilities of the radiologic and computed-tomographic examination of lizards are summarized in a bibliography. Some aspects of the topographic anatomy of this species are illustrated by one necropsy. The various parts of the gastrointestinal system were identified by histological examinations. 15 preparations of wild captured Leopard geckos were examined radiographically to describe the physiological appearance of the skeleton.15 patients received plain radiographs. 8 different boxes for the immobilization of geckos were tested for practical use. The skeleton and the respiratory tract were fully visible on all x-ray images. The differentiation of the gastrointestinal tract was increased when containing radioopaque material like sand. Eggs with calcified shells were the only detectable parts from the urogenital tract. 2 patients with anorexia and weight loss were administered 0,5 ml of a Gastrografin-water mixture in the ratio 1:3. The dosage was 2,9 or 4,9 ml Gastrografin/kg respectively. The gastrointestinal tract and the surface of the mucous membrane could be visualized very well. The first excretion of the contrast medium resulted 18 - 34 or 28 - 45 hours respectively after the administration. On one dead Leopard gecko a computed tomographic examination was done. This allowed the 3D-reconstruction of the skeleton. The advantages and disadvantages of the various fixation techniques are discussed. The possibilities of radiologic diagnostic imaging techniques for geckos are described. (author)

  4. Evaluation of radiation dose received in skull radiographic examination

    International Nuclear Information System (INIS)

    Omer, Noora Elshiekh

    2014-12-01

    Diagnostic X-ray examination play an important role in the health care of the population. These examinations may involve significant irradiation of the patient and probably represent the largest mam-made source of radiation exposure for the population. This study was performed in Khartoum Teaching Hospital in period of January to June 2014. This study was performed to assess the effective dose (ED) received in skull radiographic examination and to analyze effective dose distributions among radiological department under study. The study was performed in Khartoum Teaching Hospital, covering two x-ray units and a sample of 50 patients. The following parameters were recorded: age, weight, height, body mass index (BMI) derived from weight (kg) and (height (m)) and exposure factors. The dose was measured for skull x-ray examinations. For effective dose calculation, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for skull AP and lateral examinations. The ED values were then calculated from the obtained ESD values using IAEA calculation methods. Effective doses were calculated from energy imparted using ED conversion factors proposed were within the normal range of exposure. The mean ED values calculated were 3.03±0.08 and 4.23±0.61 for skull AP and lateral examination, respectively. Further studies are recommended with more number of patients and using more than two modalities for comparison. (Author)

  5. Assessment of dose in cervical vertebrae radiographic examinations

    International Nuclear Information System (INIS)

    Owrnasir, Wafa Fadol Orsud

    2014-12-01

    Reference dose levels provide a framework to reduce doses variability and aid in the optimization of radiation protection.This study was performed in Khartoum Teaching Hospital in period of January to June 2014. This study performed to assess the entrance surface dose ( ESD) received in Cervical Vertebrae radiographic examination and to analyze effective dose distributions among radiological departments under study. The study was performed in Khartoum Teaching Hospital, covering two x-ray units and a sample of 64 patients. The following parameter were recorded; age, weight, height, body mass index (BMI) derived from weight (kg) and height (m) and exposure factors. The dose was measured for Cervical Vertebrae x-ray examinations, the entrance surface dose (ESD) values were estimated from the x-ray tube output parameters for Cervical Vertebrae AP and lateral examinations. The ESD values were then calculated using IAEA calculation methods. The results of ESD values calculated showed than patient exposure were within the normal range of exposure. The mean ED values calculated were ( 3.85 ±0.04) and (4.02 ±0.05) mGy for Cervical Vertebrae AP and lateral examinations, respectively in department Na1 and (3.99± 0.15) and (4.23± 0.34) mGy, for Cervical Vertebrae Ap and lateral examinations respectively in department Na2, the IAEA standard value of ESD for cervical equal (7), (20) mGy AP and LAT, Further studies are recommended with more number of patients and using more than two modalities for comparison. (Author)

  6. Radiation absorbed doses at radiographic examination of third molars

    International Nuclear Information System (INIS)

    Rehnmark-Larsson, S.; Stenstroem, B.; Julin, P.; Richter, S.; Huddinge University Hospital

    1981-01-01

    The radiation absorbed doses to critical organs, i.e. the thyroid and salivary glands and the gonadal region, were measured at radiographic examination of third molars. A tissue equivalent phantom was used together with ionization chamber detectors and TLDs. The greatest thyroid dose, 35 μGy, came from a mandibular disto-oblique projection with the circular tube collimator and Ultra-Speed film. The doses in different parts of the parotid gland from the disto-oblique mandibular projection with Ultra-Speed film ranged between 2.65 and 0.052 mGy. the corresponding doses in the submandibular gland were 1.74 mGy beneath the mandible and 0.458 mGy in the fovea. A rectangular tube collimator reduced the doses by approximately 50 %. The Ekta-Speed film requirted approximately 40 % lower exposure than the Ultra-Speed film. A horizontal radiation shield reduced the thyroid doses by between 12 and 46 % and the gonadal doses by between 50 and 95 %. The reduction effect from the shield was relatively greater when using the larger aperture of the tube collimator. Combinations of leaded aprons and soft leaded collars reduced the thyroid doses between 15 and 42 % and the gonadal doses by two orders of magnitude. (Authors)

  7. Radiation absorbed doses at radiographic examination of third molars.

    Science.gov (United States)

    Rehnmark-Larsson, S; Stenström, B; Julin, P; Richter, S

    1982-01-01

    The radiation absorbed doses to critical organs, i.e. the thyroid and salivary glands and the gonadal region, were measured at radiographic examination of third molars. A tissue equivalent phantom was used together with ionization chamber detectors and TLDs. In the maxilla three, and in the mandible four different projections were used; also an extraoral lateral view. The greatest thyroid dose, 35 muGy, came from a mandibular disto-oblique projection with the circular tube collimator and Ultra-Speed film. the thyroid dose from an extraoral lateral view with high sensitivity screens was 3.7 muGy. The doses in different parts of the parotid gland from the disto-oblique mandibular projection with Ultra-Speed film ranged between 2.65 and 0.052 mGy. The corresponding doses in the submandibular gland were 1.74 mGy beneath the mandible and 0.458 mGy in the fovea. A rectangular tube collimator reduced the doses by approximately 50%. the Ekta-Speed film required approximately 40% lower exposure than the Ultra-Speed film. Without shielding the gonadal doses from a complete examination of four third molars were of the same order of magnitude as from a full survey with intraoral films, i.e. 3-7 muGy. A horizontal radiation shield reduced the thyroid doses by between 12 and 46% and the gonadal doses by between 50 and 95%. The reduction effect from the shield was relatively greater when using the larger aperture of the tube collimator. Combinations of leaded aprons and soft leaded collars reduced the thyroid doses by between 15 and 42% and the gonadal doses by two orders of magnitude.

  8. Is the gravity effect of radiographic anatomic features enough to justify stone clearance or fragments retention following extracorporeal shock wave lithotripsy (SWL).

    Science.gov (United States)

    Mustafa, Mahmoud

    2012-08-01

    We determined whether the gravity effect of radiographic anatomic features on the preoperative urography (IVP) are enough to predict fragments clearance after shock wave lithotripsy (SWL). A Total of 282 patients with mean age 45.8 ± 13.2 years (189 male, 93 female), who underwent SWL due to renal calculi between October 2005 and August 2009 were enrolled. The mean calculi load was 155.72 ± 127.66 mm². The patients were stratified into three groups: patients with pelvis calculi (group 1); patients with upper or middle pole calculi (group 2) and patients with lower pole calculi (group 3). Three angles on the pretreatment IVP were measured: the inner angle between the axis of the lower pole infundibular and ureteropelvic axis (angle I); the inner angle between the lower pole infundibular axis and main axis of pelvis-ureteropelvic (UP) junction point (angle II) and the inner angle between the lower pole infundibular axis and perpendicular line (angle III). Multivariate analysis was used to define the significant predictors of stone clearance. The overall success rate was 85.81%. All angles, sessions number, shock waves number and stone burden were significant predictors of success in patients in group 1. However, in group 2 only angle II and in group 3 angles I and II had significant effect on stone clearance. Radiographic anatomic features have significant role in determining the stone-free rate following satisfactory fragmentation of renal stones with SWL. The measurement of infundibulopelvic angle in different manner helps to predict the stone-free status in patients with renal calculi located not only in lower pole, but also in renal pelvis and upper or middle pole. Gravity effect is not enough to justify the significant influence of the radiographic anatomic features on the stone clearance and fragments retention after SWL.

  9. Study on application of contrastmeter in radiographic examination, 1

    International Nuclear Information System (INIS)

    Ooka, Kiichi; Hirayama, Kazuo; Senda, Tomio.

    1986-01-01

    As a check on the image quality of radiograph, it is customary to place a Image Quality Indicator, I. Q. I., and a contrastmeter. Although the observation results of I. Q. I. on the radiograph are affected remarkably by the difference amonge individuals, the density difference of contrastmeter dose not depend on it since the radiographic density is measured with densitometer. In order to apply both I. Q. I. and contrastmeter on all material thickness, it is necessary to know the quantitative relationship between the I. Q. I. sensitivity and the density difference in the contrastmeter. The quantitative relationship for aluminium welds are discussed. The value of dennity difference when the I. Q. I. sensitivity is considered is suitable for controlling the image quality of radiograph. For the reason that the value of density difference of contrastmeter is not strongly infuluenced, it is necessary for adopting the value obtained by dividing the density difference by radiographic density. The dimension of contrastmeter for Aluminium welds more over 20 mm in material thickness should be 20 mm in width and 3.0 mm and 4.0 mm in thickness corresponding to the material thickness. (author)

  10. Relationship of orthopedic examination, goniometric measurements, and radiographic signs of degenerative joint disease in cats

    OpenAIRE

    Lascelles, B Duncan X; Dong, Yaa-Hui; Marcellin-Little, Denis J; Thomson, Andrea; Wheeler, Simon; Correa, Maria

    2012-01-01

    Abstract Background Available information suggests a mismatch between radiographic and orthopedic examination findings in cats with DJD. However, the extent of the discrepancy between clinical and radiographic signs of OA in companion animals has not been described in detail. This study aimed to evaluate the relationship between orthopedic examination findings, joint goniometry, and radiographic signs of DJD in 100 cats, in a prospective observational design. Cat temperament, pain response to...

  11. Pre-procedural scout radiographs are unnecessary for routine pediatric fluoroscopic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Creeden, Sean G.; Rao, Anil G.; Eklund, Meryle J.; Hill, Jeanne G.; Thacker, Paul G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2017-03-15

    Although practice patterns vary, scout radiographs are often routinely performed with pediatric fluoroscopic studies. However few studies have evaluated their utility in routine pediatric fluoroscopy. To evaluate the value of scout abdomen radiographs in routine barium or water-soluble enema, upper gastrointestinal (GI) series, and voiding cystourethrogram pediatric fluoroscopic procedures. We retrospectively evaluated 723 barium or water-soluble enema, upper GI series, and voiding cystourethrogram fluoroscopic procedures performed at our institution. We assessed patient history and demographics, clinical indication for the examination, prior imaging findings and impressions, scout radiograph findings, additional findings provided by the scout radiograph that were previously unknown, and whether the scout radiograph contributed any findings that significantly changed management. We retrospectively evaluated 723 fluoroscopic studies (368 males and 355 females) in pediatric patients. Of these, 700 (96.8%) had a preliminary scout radiograph. Twenty-three (3.2%) had a same-day radiograph substituted as a scout radiograph. Preliminary scout abdomen radiographs/same-day radiographs showed no new significant findings in 719 (99.4%) studies. New but clinically insignificant findings were seen in 4 (0.6%) studies and included umbilical hernia, inguinal hernia and hip dysplasia. No findings were found on the scout radiographs that would either alter the examination performed or change management with regard to the exam. Pre-procedural scout abdomen radiographs are unnecessary in routine barium and water-soluble enema, upper GI series, and voiding cystourethrogram pediatric fluoroscopic procedures and can be substituted with a spot fluoroscopic last-image hold. (orig.)

  12. Patient exposures from intra-oral dental radiographic examinations

    International Nuclear Information System (INIS)

    Acram, S.Y.

    1987-01-01

    This report describes a study to determine patient exposure to selected areas at the thyroid gland, the central chest area, the testes and ovaries, from conventional radiographic procedures for dental patients. The study was designed also to compare the efficiency of the cervical lead shield with the lead apron which both serve as protection from radiation. The exposure levels for all radiographic procedures are as follows. The dose received by the thyroid gland area with a lead apron is approximately 300 mR and without the lead apron 350 mR. The dose received by the thyroid gland area with the use of a cervical lead shield was decreased to 30 - 35 mR for a single X-ray. The cervical lead shield reduced the radiation dose as much as 90% in the thyroid region. The thyroid gland is of great importance for radiation protection in dental radiography because of the possible relationship between thyroid cancer and radiation. The radiation dose for the molar and pre-molar area in a series of status X-rays is 1800 - 2600 mR. The dose which reaches the chest area with or without a lead apron or cervical lead shield, is 50 mR. 14 refs.; 1 figure

  13. Assessment of radiation protection awareness and knowledge about radiological examination doses among Italian radiographers.

    Science.gov (United States)

    Paolicchi, F; Miniati, F; Bastiani, L; Faggioni, L; Ciaramella, A; Creonti, I; Sottocornola, C; Dionisi, C; Caramella, D

    2016-04-01

    To evaluate radiation protection basic knowledge and dose assessment for radiological procedures among Italian radiographers A validated questionnaire was distributed to 780 participants with balanced demographic characteristics and geographic distribution. Only 12.1 % of participants attended radiation protection courses on a regular basis. Despite 90 % of radiographers stating to have sufficient awareness of radiation protection issues, most of them underestimated the radiation dose of almost all radiological procedures. About 5 % and 4 % of the participants, respectively, claimed that pelvis magnetic resonance imaging and abdominal ultrasound exposed patients to radiation. On the contrary, 7.0 % of the radiographers stated that mammography does not use ionising radiation. About half of participants believed that radiation-induced cancer is not dependent on age or gender and were not able to differentiate between deterministic and stochastic effects. Young radiographers (with less than 3 years of experience) showed a higher level of knowledge compared with the more experienced radiographers. There is a substantial need for radiographers to improve their awareness of radiation protection issues and their knowledge of radiological procedures. Specific actions such as regular training courses for both undergraduate and postgraduate students as well as for working radiographers must be considered in order to assure patient safety during radiological examinations. • Radiographers should improve their knowledge on radiation protection issues. • Only 12.1 % of participants attended radiation protection courses on a regular basis. • Specific actions must be considered in order to increase knowledge and awareness.

  14. Filmless versus film-based systems in radiographic examination costs: an activity-based costing method

    Directory of Open Access Journals (Sweden)

    Sase Yuji

    2011-09-01

    Full Text Available Abstract Background Since the shift from a radiographic film-based system to that of a filmless system, the change in radiographic examination costs and costs structure have been undetermined. The activity-based costing (ABC method measures the cost and performance of activities, resources, and cost objects. The purpose of this study is to identify the cost structure of a radiographic examination comparing a filmless system to that of a film-based system using the ABC method. Methods We calculated the costs of radiographic examinations for both a filmless and a film-based system, and assessed the costs or cost components by simulating radiographic examinations in a health clinic. The cost objects of the radiographic examinations included lumbar (six views, knee (three views, wrist (two views, and other. Indirect costs were allocated to cost objects using the ABC method. Results The costs of a radiographic examination using a filmless system are as follows: lumbar 2,085 yen; knee 1,599 yen; wrist 1,165 yen; and other 1,641 yen. The costs for a film-based system are: lumbar 3,407 yen; knee 2,257 yen; wrist 1,602 yen; and other 2,521 yen. The primary activities were "calling patient," "explanation of scan," "take photographs," and "aftercare" for both filmless and film-based systems. The cost of these activities cost represented 36.0% of the total cost for a filmless system and 23.6% of a film-based system. Conclusions The costs of radiographic examinations using a filmless system and a film-based system were calculated using the ABC method. Our results provide clear evidence that the filmless system is more effective than the film-based system in providing greater value services directly to patients.

  15. Filmless versus film-based systems in radiographic examination costs: an activity-based costing method.

    Science.gov (United States)

    Muto, Hiroshi; Tani, Yuji; Suzuki, Shigemasa; Yokooka, Yuki; Abe, Tamotsu; Sase, Yuji; Terashita, Takayoshi; Ogasawara, Katsuhiko

    2011-09-30

    Since the shift from a radiographic film-based system to that of a filmless system, the change in radiographic examination costs and costs structure have been undetermined. The activity-based costing (ABC) method measures the cost and performance of activities, resources, and cost objects. The purpose of this study is to identify the cost structure of a radiographic examination comparing a filmless system to that of a film-based system using the ABC method. We calculated the costs of radiographic examinations for both a filmless and a film-based system, and assessed the costs or cost components by simulating radiographic examinations in a health clinic. The cost objects of the radiographic examinations included lumbar (six views), knee (three views), wrist (two views), and other. Indirect costs were allocated to cost objects using the ABC method. The costs of a radiographic examination using a filmless system are as follows: lumbar 2,085 yen; knee 1,599 yen; wrist 1,165 yen; and other 1,641 yen. The costs for a film-based system are: lumbar 3,407 yen; knee 2,257 yen; wrist 1,602 yen; and other 2,521 yen. The primary activities were "calling patient," "explanation of scan," "take photographs," and "aftercare" for both filmless and film-based systems. The cost of these activities cost represented 36.0% of the total cost for a filmless system and 23.6% of a film-based system. The costs of radiographic examinations using a filmless system and a film-based system were calculated using the ABC method. Our results provide clear evidence that the filmless system is more effective than the film-based system in providing greater value services directly to patients.

  16. Value of radiographic examination of the knee joint for the orthopedic surgeon

    International Nuclear Information System (INIS)

    Pietsch, M.; Hofmann, S.

    2006-01-01

    Extended radiographic examinations offer excellent options for diagnosis and strategy for treatment of the knee joint. The whole-leg radiograph is indispensable in measuring alignment for osteotomy or total knee arthroplasty (TKA). Fluoroscopically assisted varus-valgus stress radiographs provide the possibility for verifying mechanical function of the implanted knee prosthesis. Ultrasound examinations have been widely replaced by magnetic resonance imaging (MRI). MRI is the golden standard to examine intra-articular structures of the knee (meniscus, ligaments, cartilage) and surrounding soft tissue. For evaluating femoral and tibial torsion and determining axial rotation of TKA, computed tomography (CT) is best qualified. Imaging of the patellofemoral joint (patella instability) is difficult; CT scans in combination with true lateral radiographs seem to be helpful. (orig.) [de

  17. Conventional radiographic examination in the evaluation of sequelae after tibial plateau fractures

    International Nuclear Information System (INIS)

    Jensen, D.B.; Bjerg-Nielsen, A.; Laursen, N.; Glostrup Univ. Hospital

    1988-01-01

    Seventy patients with 72 conservatively treated tibial plateau fractures were re-examined after an average of 5 3/4 years. Among 55 fractured knees with a primary articular depression of 1-20 mm, the depression was still present radiographically in 47 knees. No correlation existed between the persistent radiographic depression and function of the knee. Moderate to severe osteoarthrosis was found in 10 knees; in five of these the osteoarthrosis was of clinical importance. More than 10 degrees of valgus/varus deformity was present in two knees. In two patients osteotomy had been performed to correct deformity. It is concluded that a persistent radiographic articular depression is of no clinical importance in tibial plateau fractures treated by conservative methods, which include early movement of the knee. The radiographic examination, however is, useful in the evaluation of valgus/varus deformity and osteoarthrosis. (orig.)

  18. Children’s experience of going through an acute radiographic examination

    International Nuclear Information System (INIS)

    Björkman, B.; Almqvist, L.; Sigstedt, B.; Enskär, K.

    2012-01-01

    Children’s experience of radiographic examinations remains largely unexplored, although most radiographers examine children on a daily basis. In order to provide the high quality care that meets the needs of patients it was considered important to undertake research focused upon the patients’ experience of radiographic practice. The aim of the study was to investigate children’s experiences undergoing a radiographic examination for a suspected fracture. Inclusion criteria were Swedish-speaking children between 3 and 15 years of age who were submitted for a radiographic examination with an acute condition of the upper or lower extremity. Patients were informed of the study and together with the escorting parent or relative asked for consent to participate. During the examination the child was videotaped and immediately after, the child was interviewed in a nearby facility. The interview contained open-ended questions and was conducted while watching the videotape together with the child and their parent or relative and the researcher. Qualitative content analysis was used in analyzing the collected data. The analysis resulted in two categories – “feeling uncomfortable” and “feeling confident”. The subcategories contained in these categories were “pain in relation to injury and examination”, “the waiting time is strenuous”, “worries for the future and consequences of the injury”, “confidence in parental presence”, “confidence in radiographic staff and examination procedure”, and finally “recognition entails familiarity”. The results revealed that for the younger children, the experience of undergoing an acute radiographic examination was associated with pain and anxiety, but for the older children, the anxiety was more connected to whether the injury had caused a fracture and any anticipated future consequences or complications.

  19. Patient doses from diagnostic radiographic examinations in Syria

    International Nuclear Information System (INIS)

    Kharita, M.H.; Khedr, M.; Wannus, K.

    2009-05-01

    The aim of this study is to evaluate radiation doses received by adult patients undergoing 9 routine common types of x-ray examination in Syria covering (chest PA, lumbar spine PA, lumbar spine LAT, Urography, abdomen, pelvis and hip, head, shoulder and extremities). The study consisted of measurements for 1308 x-ray examination for patients in 26 public hospitals. The average effective dose imparted to each patient per examination was computed from measurement of dose area product for the examination and using the X-dose software, the result of the effective dose except for extremities are gradually (0.125, 1.67, 1.23, 2.7, 1.07, 0.85, 0.05 and 0.025) and the average of the DAP for extremities was 0.095 Gy.cm 2 . (author)

  20. Development of radiographic technique for examining k-type butt weld

    International Nuclear Information System (INIS)

    Barui, K.L.; Bhattacharyya, B.

    1983-01-01

    An attempt is made to develop a radiographic technique for examining K-type full penetration butt joints in heavy duty crane girders. The existing standard techniques of radiographic examination is found to be unsuitable to assess the internal defects properly. The examination technique reported here is successful in detecting not only the nature of the internal defects but also their degree of severities - from which clues for avoiding the most probable defects can be found out. The results of radiographic examination applied on the K-type butt joints of heavy duty crane girders have been discussed and it is specified that the acceptable limit of the defects must lie between 'blue' and 'green' according to the IIW colour code. Much work is yet to be done before standard specifications regarding the acceptibility of the defects in the actual job can be formulated. (author)

  1. Method for the radiographic examination of an object

    International Nuclear Information System (INIS)

    1979-01-01

    Method for the examination of a separate sample taken from a massive material by means of X-radiation, characterised in that the sample is placed in a medium in such a manner that the total X-ray absorption of medium and sample in the path of the X-radiation is substantially uniform, and eventually the pattern formed by the transmitted radiation is recorded. (G.C.)

  2. Diagnostic accuracy of radiographer reporting of computed tomography colonography examinations: A systematic review

    International Nuclear Information System (INIS)

    Meertens, R.; Brealey, S.; Nightingale, J.; McCoubrie, P.

    2013-01-01

    Computed tomography colonography (CTC) is the primary radiological test for the detection of colorectal tumours and precancerous polyps. Radiographer reporting of CTC examinations could help to improve the provision of this expanding service. We undertook a systematic review to assess the accuracy with which radiographers can provide formal written reports on intraluminal disease entities of CTC examinations compared to a reference standard. Data sources searched included online databases, peer-reviewed journals, grey literature, and reference and citation tracking. Eligible studies were assessed for bias, and data were extracted on study characteristics. Pooled estimates of sensitivities and specificities and chi-square tests of heterogeneity were calculated. Eight studies were eligible for inclusion with some risk to bias. Pooled estimates from three studies showed per patient sensitivity and specificity of reporting radiographers was 76% (95% CI: 70–80%) and 74% (95% CI: (67–80%), respectively. From seven studies, per lesion sensitivity for the detection of lesions >5 and >10 mm was 68% (95% CI: 65–71%) and 75% (95% CI: 72–79%) respectively. Pooled sensitivity for detection of lesions >5 mm in studies for which radiographers reported 50 or less training cases was 57% (95% CI: 52–61%) and more than 50 cases was 78% (95% CI: 74–81%). The current evidence does not support radiographers in a role involving the single formal written reporting of CTC examinations. Radiographers' performance, however, did appear to improve significantly with the number read. Therefore, when provided with adequate training and experience, there may be a potential role for radiographers in the reporting of CTC examinations

  3. Diagnostic Yield of Recommendations for Chest CT Examination Prompted by Outpatient Chest Radiographic Findings

    Science.gov (United States)

    Harvey, H. Benjamin; Gilman, Matthew D.; Wu, Carol C.; Cushing, Matthew S.; Halpern, Elkan F.; Zhao, Jing; Pandharipande, Pari V.; Shepard, Jo-Anne O.

    2015-01-01

    Purpose To evaluate the diagnostic yield of recommended chest computed tomography (CT) prompted by abnormalities detected on outpatient chest radiographic images. Materials and Methods This HIPAA-compliant study had institutional review board approval; informed consent was waived. Reports of all outpatient chest radiographic examinations performed at a large academic center during 2008 (n = 29 138) were queried to identify studies that included a recommendation for a chest CT imaging. The radiology information system was queried for these patients to determine if a chest CT examination was obtained within 1 year of the index radiographic examination that contained the recommendation. For chest CT examinations obtained within 1 year of the index chest radiographic examination and that met inclusion criteria, chest CT images were reviewed to determine if there was an abnormality that corresponded to the chest radiographic finding that prompted the recommendation. All corresponding abnormalities were categorized as clinically relevant or not clinically relevant, based on whether further work-up or treatment was warranted. Groups were compared by using t test and Fisher exact test with a Bonferroni correction applied for multiple comparisons. Results There were 4.5% (1316 of 29138 [95% confidence interval {CI}: 4.3%, 4.8%]) of outpatient chest radiographic examinations that contained a recommendation for chest CT examination, and increasing patient age (P recommendation for chest CT examination. Of patients within this subset who met inclusion criteria, 65.4% (691 of 1057 [95% CI: 62.4%, 68.2%) underwent a chest CT examination within the year after the index chest radiographic examination. Clinically relevant corresponding abnormalities were present on chest CT images in 41.4% (286 of 691 [95% CI: 37.7%, 45.2%]) of cases, nonclinically relevant corresponding abnormalities in 20.6% (142 of 691 [95% CI: 17.6%, 23.8%]) of cases, and no corresponding abnormalities in 38

  4. Dosimetry for Patients undergoing Radiographic Examinations in Sudan

    International Nuclear Information System (INIS)

    Halato, M.A.; Kafi, S.T.; Ahmed, A.M.; Sid Ahamed, F.A.; Ibrahim, Z.; Suliman, M.F.; Suliman, I.I.

    2009-01-01

    In this study we estimated the entrance skin doses ESDs for patients undergoing selected diagnostic X -ray examinations in two large public hospitals in Khartoum state, Sudan. The study included the examinations of the chest posterior-anterior (PA) , skull antero-posterior (AP), skull Lateral (LAT) , Lumber spine AP/LAT, abdomen Intravenous urogram (IVU) and Pelvis AP. Totally, 241 patients were included in this study. ESDs were estimated from patients specific exposure parameters using established relation between output (μ Gy/mAs) and tube voltage (kVp). The estimated ESDs ranged from 0.18 - 1.05 mGy for chest PA, 0.98 - 3.48 mGy for Skull (AP), 0.66 - 2.75 mGy for skull (LAT), 1.22 - 4.35 mGy for abdomen (IVU), 1.18 - 5.75 mGy for Pelvis, 1.52 - 5.01 mGy Lumbar spine AP and 2.48 - 10.41 mGy for Lumbar spine (LAT). These values compare well with the international reference dose levels. This study provides additional data that can help the regulatory authority to establish reference dose level for diagnostic radiology in Sudan

  5. Relationship of orthopedic examination, goniometric measurements, and radiographic signs of degenerative joint disease in cats.

    Science.gov (United States)

    Lascelles, B Duncan X; Dong, Yaa-Hui; Marcellin-Little, Denis J; Thomson, Andrea; Wheeler, Simon; Correa, Maria

    2012-01-27

    Available information suggests a mismatch between radiographic and orthopedic examination findings in cats with DJD. However, the extent of the discrepancy between clinical and radiographic signs of OA in companion animals has not been described in detail. This study aimed to evaluate the relationship between orthopedic examination findings, joint goniometry, and radiographic signs of DJD in 100 cats, in a prospective observational design. Cat temperament, pain response to palpation, joint crepitus, effusion and thickening were graded. Radiographs of appendicular joints and the axial skeleton were made under sedation. Joint motion was measured by use of a plastic goniometer before and after sedation. Associations between radiographic degenerative joint disease (DJD) and examination findings were assessed to determine sensitivity, specificity and likelihood estimations. Pain response to palpation was elicited in 0-67% of the joints with DJD, with a specificity ranging from 62-99%; crepitus was detected in 0-56% of the joints and its specificity varied between 87 and 99%; for effusion, values ranged between 6 and 38% (specificity, 82-100%), and thickening, 0-59% (specificity, 74-99%). Joints with DJD tended to have a decreased range of motion. The presence of pain increased the odds of having DJD in the elbow (right: 5.5; left: 4.5); the presence of pain in the lower back increased the odds of spinal DJD being present (2.97 for lumbar; 4.67 for lumbo-sacral). Radiographic DJD cannot be diagnosed with certainty using palpation or goniometry. However, negative findings tend to predict radiographically normal joints. Palpation and goniometry may be used as a tool to help to screen cats, mostly to rule out DJD.

  6. Relationship of orthopedic examination, goniometric measurements, and radiographic signs of degenerative joint disease in cats

    Directory of Open Access Journals (Sweden)

    Lascelles B Duncan X

    2012-01-01

    Full Text Available Abstract Background Available information suggests a mismatch between radiographic and orthopedic examination findings in cats with DJD. However, the extent of the discrepancy between clinical and radiographic signs of OA in companion animals has not been described in detail. This study aimed to evaluate the relationship between orthopedic examination findings, joint goniometry, and radiographic signs of DJD in 100 cats, in a prospective observational design. Cat temperament, pain response to palpation, joint crepitus, effusion and thickening were graded. Radiographs of appendicular joints and the axial skeleton were made under sedation. Joint motion was measured by use of a plastic goniometer before and after sedation. Associations between radiographic degenerative joint disease (DJD and examination findings were assessed to determine sensitivity, specificity and likelihood estimations. Results Pain response to palpation was elicited in 0-67% of the joints with DJD, with a specificity ranging from 62-99%; crepitus was detected in 0-56% of the joints and its specificity varied between 87 and 99%; for effusion, values ranged between 6 and 38% (specificity, 82-100%, and thickening, 0-59% (specificity, 74-99%. Joints with DJD tended to have a decreased range of motion. The presence of pain increased the odds of having DJD in the elbow (right: 5.5; left: 4.5; the presence of pain in the lower back increased the odds of spinal DJD being present (2.97 for lumbar; 4.67 for lumbo-sacral. Conclusions Radiographic DJD cannot be diagnosed with certainty using palpation or goniometry. However, negative findings tend to predict radiographically normal joints. Palpation and goniometry may be used as a tool to help to screen cats, mostly to rule out DJD.

  7. Brazilian young dental practitioners' use and acceptance of digital radiographic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Rovaris, Karla; De Faria Vasconcelos, Karla; Do Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Freitas, Deborah Queiroz; Haiter-Neto, Francisco [Div. of Oral Radiology, Dept. of Oral Diagnosis, Piracicaba Dental School, University of Campinas (UNICAMP), Sao Paulo (Brazil)

    2016-12-15

    The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self-administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (α=0.05). A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p=0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations.

  8. Brazilian young dental practitioners' use and acceptance of digital radiographic examinations

    International Nuclear Information System (INIS)

    Rovaris, Karla; De Faria Vasconcelos, Karla; Do Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Freitas, Deborah Queiroz; Haiter-Neto, Francisco

    2016-01-01

    The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self-administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (α=0.05). A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p=0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations

  9. Brazilian young dental practitioners' use and acceptance of digital radiographic examinations.

    Science.gov (United States)

    Rovaris, Karla; de Faria Vasconcelos, Karla; do Nascimento, Eduarda Helena Leandro; Oliveira, Matheus Lima; Freitas, Deborah Queiroz; Haiter-Neto, Francisco

    2016-12-01

    The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self-administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (α=0.05). A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p=0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations.

  10. Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea

    International Nuclear Information System (INIS)

    Choi, Jin Woo

    2010-01-01

    To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was 128.0 mGy cm2 and 3rd quartile dose (DAP) 161.1 mGy cm2 for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, respectively. The average patient dose was 128.0 mGy cm2 and the third quartile patient dose 161.1 mGy cm2 for lateral cephalometric radiography for adult male in Korea.

  11. Children’s pain and distress while undergoing an acute radiographic examination

    International Nuclear Information System (INIS)

    Björkman, B.; Nilsson, S.; Sigstedt, B.; Enskär, K.

    2012-01-01

    Pain has been highlighted as a main concern for children in conjunction with an acute radiographic examination. The aim of this study was to further investigate children’s pain and distress while undergoing an acute radiographic examination. The study comprised 29 participants with an age range of 5–15 years who were injured and submitted to an acute radiographic examination of the upper or lower extremity when the question at issue was fracture. The Coloured Analogue Scale (CAS) and the Facial Affective Scale (FAS) were used as self-reporting scales to measure the children’s pain and distress. The Face, Legs, Activity, Cry and Consolability Behavioural scale (FLACC) was used as an observation tool to assess behaviours associated with pain in children. Descriptive statistics were used when analysing the scores, and the results showed that children experience pain and distress in conjunction with a radiographic examination after an injury. Spearman’s correlation was used to compare variables, and significant correlations were obtained between the self-reported pain and the observed pain behaviour. Fischer’s Exact test was used to compare groups, and when using the cut-off 3.0 on the self-reporting scale no significant correlation was found concerning the pain reported by children diagnosed with and without a fracture. No significant correlations were found concerning the self-reported distress and pain either, regardless of whether it was a first-time visit and whether a parent was near during the examination.

  12. General practitioners' willingness to request plain lumbar spine radiographic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Ryynaenen, Olli-Pekka E-mail: ollipekka.ryynanen@uku.fi; Lehtovirta, Jukka; Soimakallio, Seppo; Takala, Jorma

    2001-01-01

    Objectives: To examine general practitioners' attitudes to plain lumbar spine radiographic examinations. Design: A postal questionnaire consisting of questions on background data and doctors' opinions about plain lumbar spine radiographic examinations, as well as eight vignettes (imaginary patient cases) presenting indications for lumbar radiography, and five vignettes focusing on the doctors' willingness to request lumbar radiography on the basis of patients' age and duration of symptoms. The data were analysed according to the doctor's age, sex, workplace and the medical school of graduation. Setting: Finland. Subjects: Six hundred and fifteen randomly selected physicians working in primary health care (64% of original target group). Results: The vignettes revealed that the use of plain lumbar radiographic examination varied between 26 and 88%. Patient's age and radiation protection were the most prominent factors influencing doctors' decisions to request lumbar radiographies. Only slight differences were observed between the attitudes of male and female doctors, as well as between young and older doctors. Doctors' willingness to request lumbar radiographies increased with the patient's age in most vignettes. The duration of patients' symptoms had a dramatic effect on the doctor's decision: in all vignettes, doctors were more likely to request lumbar radiography when patient's symptoms had exceeded 4 weeks. Conclusions: General practitioners commonly use plain lumbar spine radiographic examinations, despite its limited value in the diagnosis of low back pain. Further consensus and medical education is needed to clarify the indications for plain lumbar radiographic examination.

  13. The diagnostic value of the 'skyline' view for radiographic examination of the equine navicular bone

    International Nuclear Information System (INIS)

    Zweers, A.D.; Dik, K.J.

    1988-01-01

    The radiographic diagnostic value of Rose's palmaroproximal-dorsodistal ('skyline') projection and Oxspring's dorsopalmar projection of the equine navicular bone were compared, by examining radiographs of 102 navicular bones originating from 66 randomly selected horses with clinical evidence of lameness located in the navicular area. In 27 navicular bones essential information was obtained from the skyline view, 15 independently of Oxspring's projection and 12 in addition to this view. For 11 navicular studies the D.P. projection was the most important diagnostic view. In the other 64 navicular bones information obtained from both views was of equal diagnostic value. Based on these results it is suggested that the skyline projection be utilized as an additional view, especially if there is a significant discrepancy between the clinical and radiographic findings based on lateromedial and Oxspring projections, and if ill-defined lesions of unknown significance are visible on the Oxspring projection [nl

  14. Radiographic examination of the hoof joint and navicular bone for the reason of prepurchase examination of the horse

    International Nuclear Information System (INIS)

    Zert, Z.; Sterc, J.; Bartunkova, H.

    2002-01-01

    The optimal radiographic examination of the equine hoofjoint and navicular bone requires lateral, dorsopalmar and oblique proximodistal-palmarodistal (tangential) projections. The radiographic method used and the choice of the material are crucial elements for the image quality and the usefulness of the examination. It is not always easy to obtain precise lateral view, which can help in detection of changes on the flexor surface, disclose interior structure of navicular bone, as well as facilitates observation of dorsal aspect of the hoof joint. The dorsopalmar projection can provide nearly complete information about the borders of the navicular bone and its relationship to the adjacent structures. The 55 deg PP-PD projection reveals once again flexor surface and the interior structure of navicular bone without any superposition. This projection allows demonstration of early structural changes (namely sclerosis) in the transitional zone of the facies flexora bone plate and the navicular spongious bone

  15. Radiation exposure from conventional radiographic examinations in very and extremely low birth weight patients

    Science.gov (United States)

    Gois, M. L. C.; Schelin, H. R.; Denyak, V.; Bunick, A. P.; Legnani, A.; Paschuk, S. A.

    2017-11-01

    The survival of very premature neonates has improved significantly at the last decades owing to the utilization of modern intensive care interventions that usually requires prolonged hospitalisation and are accompanied by frequent radiographic examinations. Their elevated radiosensitivity and numerous examinations combined with their greater remaining lifetime raise the issue of high risk for radiation-induced malignancies. Because it is presently impossible to substitute this type of examinations with others that do not involve radiation exposure, investigations on a hospital's routine practices becomes relevant. In this work, we present the results of an investigation on the radiation exposure of patients with birth weight lower than 1500 g in one paediatric hospital in Brazil. We analyse some important patient characteristics, like weight, gestational age, length of stay, and number of radiographs performed in the neonatal intensive care unit, in connection with the patient dose. The obtained results are compared with the existing information from other studies.

  16. A computer-assisted procedure for estimating patient exposure and fetal dose in radiographic examinations

    International Nuclear Information System (INIS)

    Glaze, S.; Schneiders, N.; Bushong, S.C.

    1982-01-01

    A computer program for calculating patient entrance exposure and fetal dose for 11 common radiographic examinations was developed. The output intensity measured at 70 kVp and a 30-inch (76-cm) source-to-skin distance was entered into the program. The change in output intensity with changing kVp was examined for 17 single-phase and 12 three-phase x-ray units. The relationships obtained from a least squares regression analysis of the data, along with the technique factors for each examination, were used to calculate patient exposure. Fetal dose was estimated using published fetal dose in mrad (10 -5 Gy) per 1,000 mR (258 μC/kg) entrance exposure values. The computations are fully automated and individualized to each radiographic unit. The information provides a ready reference in large institutions and is particularly useful at smaller facilities that do not have available physicists who can make the calculations immediately

  17. A computer-assisted procedure for estimating patient exposure and fetal dose in radiographic examinations

    International Nuclear Information System (INIS)

    Glaze, S.; Schneiders, N.; Bushong, S.C.

    1982-01-01

    A computer program for calculating patient entrance exposure and fetal dose for 11 common radiographic examinations was developed. The output intensity measured at 70 kVp and a 30-inch (76-cm) source-to-skin distance was entered into the program. The change in output intensity with changing kVp was examined for 17 single-phase and 12 three-phase x-ray units. The relationships obtained from a least squares regression analysis of the data, along with the technique factors for each examination, were used to calculate patient exposure. Fetal dose was estimated using published fetal dose in mrad (10(-5) Gy) per 1,000 mR (258 microC/kg) entrance exposure values. The computations are fully automated and individualized to each radiographic unit. The information provides a ready reference in large institutions and is particularly useful at smaller facilities that do not have available physicians who can make the calculations immediately

  18. Protocol of Radiographic Examination of Children in Order to Improve the Radiation Protection

    International Nuclear Information System (INIS)

    Milkovic, Dj.; Gunek, G.; Ranogajec-Komor, M.; Zagar, I.

    2001-01-01

    Full text: Pulmonary radiograms are essential in the diagnostics of lung diseases of children and youth. In childhood, sometimes immediately after a child's birth, there is a need to apply this diagnostic method. Namely, even in the first days of life some pathological conditions can exist which can lead to progressive respiratory failure (respiratory distress syndrome, aspirational syndrome, lung anomaly). An experienced clinician paediatrician can suspect the pathological condition, but for a sure and a timely diagnosis, a radiographic confirmation is necessary. Long lasting cough, fever and chest pain of unexplained ethiology are also indications for a radiographic examination in childhood. In the evaluation of treatment repeated radiograms are often necessary too. Considering that children are radiovulnerable population, and that during these examinations neighbouring organs (bone marrow, thyroid gland) are also irradiated, it is necessary to undertake all measures to minimise harmful consequences of irradiation during diagnostic X-ray examinations. In order to improve radiation protection, a protocol for radiographic examination of small children was worked out. Paediatricians and child-radiologists worked in producing this protocol closely together. In order to achieve a satisfactory protection of patients during respiratory tract examination the doses of radiation were controlled with thermoluminiscent dosimetric systems which had been found adequate for X-ray diagnostics dosimetry. (author)

  19. Usefulness of panoramic radiograph for the improvement of periodic oral examination

    Energy Technology Data Exchange (ETDEWEB)

    Shin, MinJung; Choi, Bo Ram; Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul [Department of Oral and Maxillofacial Radiology, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2010-03-15

    This study was designed to evaluate the efficacy and utility of panoramic radiograph for the improvement of the periodic oral examinations. Clinical examinations and panoramic examinations were done for the 242 subjects of oral examinations. The results of panoramic radiograph interpretation were compared with the clinical findings. Two questionnaires were created. One was carried out before the panoramic examination and the other done afterwards, to find out the subjects cognition and satisfaction for the clinical and panoramic examinations. Results : 1. Panoramic findings showed a higher detection rate of 31.9% for periodontal diseases, and 23.1% for dental caries than clinical findings. 2. The additional abnormalities detected through panoramic examinations were impacted tooth in 81 subjects (33.6%), maxillary sinus abnormalities in 28 subjects (11.6%), condylar abnormalities in 5 subjects (2.1%), congenital and acquired dental anormalies in 59 subjects (24.5%), and other miscellaneous abnormalities in 34 subjects (14.1%). 3. 164 subjects (67.8%) were satisfied with the current periodic oral examination, and 75 subjects (31.1%) hoped for better accuracy. 4. In the first and second questionnaire, 154 subjects (67.0%) and 163 subjects (70.6%) responded respectively that panoramic examination was necessary, and 193 subjects (83.2%) responded that it actually helped. The panoramic examination was revealed to improve the effectiveness of the periodic oral examination and to increase the satisfaction of the subjects of examination.

  20. Value of non-contrast CT examination of the urinary tract (stone ...

    African Journals Online (AJOL)

    Mohamed Samir Shaaban

    2015-09-04

    Sep 4, 2015 ... detection of abdominal pathologies other than stones, whether or not simulating the clinical picture of urolithiasis, and .... detector CT Siemens Somatom Sensation, with no oral or intravenous ..... of kidney stones in children.

  1. Influence of geometrical unsharpness on detection of tight defects by radiographic examination

    International Nuclear Information System (INIS)

    Bodson, F.; Crescenzo, E.; Thomas, A.

    1983-01-01

    A study was undertaken to evaluate the influence of geometric unsharpness on defects' visibility for radiographic examinations carried out with Iridium 192 and Cobalt 60 sources. This study enabled the authors to demonstrate that, even in the case of highly detrimental implementation conditions (increase in geometric unsharpness obtained via a reduction in the source-to-film distance, when the defect is not in the beam axis), the worsening in defects' visibility was dependent on defect type, nature of material, thickness radiographed, source energy, and geometric exposure conditions (dimension of the source, enlargement of the defect). Without establishing maximum admissible values, they nevertheless assert that these should be determined by taking these parameters into account. In particular it seems possible to accept greater geometric unsharpness values for small thicknesses than for large ones, in the examination of welded joints using Iridium 192 and Cobalt 60

  2. Gadolinium-containing contrast media for radiographic examinations: a position paper

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.; Almen, Torsten; Morcos, Sameh K.

    2002-01-01

    Recently, it has been suggested that gadolinium-based contrast media could be used for radiological examinations in patients with significant renal impairment, previous severe generalized reaction to iodinated contrast media or thyroid disease about to undergo radioactive iodine treatment; however, the indications for and risks of using gadolinium agents in this way are not well known; hence, the Contrast Media Safety Committee of The European Society of Urogenital Radiology reviewed the literature to issue a position paper on this subject. A comprehensive literature review was performed and the resulting report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy, June 2002. Review of the literature indicates that according to experimental data on animals gadolinium-based contrast media have more nephrotoxic potential than iodinated contrast media in equivalent X-ray attenuating doses; therefore, gadolinium-based contrast media should not replace iodinated contrast media in patients with renal insufficiency for radiographic examinations. For patients with previous severe generalized reactions to iodinated contrast media, and in patients about to undergo thyroid treatment with radioactive iodine gadolinium-based contrast media in approved intravenous doses, up to 0.3 mmol/kg body weight will not give diagnostic radiographic information in most cases. Gadolinium-based contrast media are not approved for radiographic examinations. (orig.)

  3. Strategies for dose reduction in ordinary radiographic examinations using CR and DR

    International Nuclear Information System (INIS)

    Willis, C.E.

    2004-01-01

    Uncoupling of display from acquisition in computed radiography (CR) and digital radiography (DR) introduces the potential for systematic overexposure without necessarily compromising image quality. Although the magnitude of radiation doses in general radiography is low compared to computed tomography and fluoroscopy, the dose to the patient is more critical in pediatric examinations than in adults, because of the greater radiosensitivity of children. This manuscript examines a variety of countermeasures for managing radiation doses in pediatric CR and DR examinations, including use of derived exposure indicators, modifications of imaging practice, and development of more efficient radiographic detectors. (orig.)

  4. A patient dose survey for femoral arteriogram diagnostic radiographic examinations using a dose-area product meter

    International Nuclear Information System (INIS)

    Thwaites, J.H.; Rafferty, M.W.; Gray, N.; Black, J.; Stock, B.

    1996-01-01

    A patient dose survey was carried out for femoral arteriogram procedures at the Sir Charles Gairdner Hospital. The procedure involves fluoroscopy to the pelvic region to locate a guide wire and catheter, followed by a series of radiographs extending from the pelvic area to the feet to form a collage image of the entire arterial system. Radiographs are taken whilst a bolus of contrast media is injected into the arterial system. A dose-area product meter was used to determine the dose-area product delivered to patients. Radiographic and patient details were logged with dose-area product for each part of each procedure. Mean energy imparted, mean effective dose and effective dose equivalent are calculated for the examinations. Calculated effective doses are shown to produce results consistent with those of other authors. We present a method for dealing with a complex radiographic procedure including multiple radiographs and fluoroscopy in an attempt to provide a simple way of calculating effective dose from which a general risk factor can be determined. The effective dose varies considerably from examination to examination due to the large range in the number of radiographs taken in any one procedure. A useful index can be obtained by logging the number of radiographs in each region, and fluoroscopy time, from which the effective dose may be easily calculated. These measurements extend a continuing survey of doses for common diagnostic radiographic examinations which previously included the simple examinations: lumbar spine, abdoment and pelvis. (author)

  5. A study of gonad doses in X-ray radiographic examinations of the abdomen

    International Nuclear Information System (INIS)

    Brown, L.D.

    1980-01-01

    A phantom study has been made in an attempt to redetermine gonad dose associated with routine X-ray diagnostic procedures. Over a range of voltages between 60 kVp and 130 kVp, TLD measurements of skin, ovary, a standardised cassette dose of 1 mrad, and testicle doses were obtained for AP, PA and lateral radiographs. Whilst exact numerical results depended greatly on the characteristics of the film-screen combination used, the contrast required in the final radiograph and the efficiency of the Bucky grid, results of this redetermination did not support the view that a reduction in population genetic dose would follow any general increase in the typical operating potential used for abdominal x-ray examinations. (U.K.)

  6. Survey of image quality and radiographic technique of pediatric chest examinations performed in Latin America

    International Nuclear Information System (INIS)

    Khoury, H.; Mora, P.; Defaz, M.Y.; Blanco, S.; Leyton, F.; Benavente, T.; Ortiz Lopez, P.; Ramirez, R.

    2008-01-01

    This work presents the results of a survey of entrance surface air kerma values (K e ), image quality and radiographic exposure parameters used in pediatric chest examinations performed in Latin America. This study is part of the activities of the IAEA Regional Project RLA/9/057 whose objective is to optimize the radiological protection of patients in diagnostic and interventional radiology, nuclear medicine and radiotherapy. The survey was performed in nine hospitals in Argentina (1), Brazil (4), Chile (1), Costa Rica (1), Peru (1) and Ecuador (1). The study group consisted of 462 pediatric patients (Group I- from two days to one year, Group II- from four to six years of age) undergoing chest PA/AP examinations. At the time of the examination the exposure parameters (kVp, mAs, focal-spot-to-film distance, etc.) and patient information (gender, height, weight and age) were recorded. The radiographic image quality was evaluated by the local radiologist based on the European Guidelines on Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The results showed that the exposure parameters used on newborn patients were in the majority outside the 60-65kV range recommended by the European Guidelines for a good radiographic practice. In the case of examinations of patients with age between 4 to 6 years, 80% were performed with a peak tube voltage within the 60-80 kV range, as recommended by the European Guidelines. It was found that none of countries fully comply with the European Guidelines on Quality Criteria and those criteria No. 2 and No. 3 (reproduction of the chest without rotation) received the lowest scores. Probably this occurs because there are no proper patient immobilization devices. The Ke values, for both patient groups, showed a wide dispersion, ranged from 10 μGy to 160μGy for the newborn patients and from 20μGy to 240μGy for infant patients. It is possible to conclude that, in the participating Latin American countries on this project

  7. Guide to nuclear medicine. A textbook for radiographers' examination and practice

    International Nuclear Information System (INIS)

    Elser, H.

    1999-01-01

    The guide to clinical applications of nuclear medicine presents a comprehensive survey of the subject field, encompassing in addition to all medical aspects information on the fundamental physics and radiochemistry involved, examination protocols, case reports, and diagnostic findings. Legal provisions and requirements as well as procedures for quality control are explained and discussed. The material of the textbook has been compiled and arranged in line with the training programme and examination requirements for radiographers, but due to the systematic design and approach and the many pictures and tables it may also be of use as a source of reference for medical students of radiology courses, or specializing doctors. (orig./CB)

  8. Preliminary analysis of doses to evaluate the image quality in radiographic examinations in veterinary radiology

    International Nuclear Information System (INIS)

    Pinto, Ana Carolina B.C.F.; Dias, Mayara T.P.; Santos, Andrea C.; Melo, Camila S.; Furquim, Tania A.C.

    2009-01-01

    This work has as objective to promote the analysis of the radiological doses and quality of the image of the technical letter used for the accomplishment of thorax and coxal radiographic examination of animals of canine and feline species. The study was accomplished in the service of Diagnosis for Image in Veterinarian Hospital of Veterinary Medicine and Zootecnia College of University of Sao Paulo, in two conventional equipment. Initially, physical features of the animals and the technique used were collected for each one of the 188 radiographic examinations of thorax and 52 examinations of coxal. The animals were placed in different groups, according to their body weight. For each group, the averages for each feature were calculated: thickness of the radiographed region, tension, electric current, time of exhibition, current product electric-time, size of the used film, presence or absence of bucky and feature of focus (narrow or thick). On the basis of the averages of group M (of lesser weights that 5kg for cats and between 10,1kg and 20kg for dogs), was executed a physical analysis of the current technical letter, using the equipment: ionization chamber (to determinate the value of kerma in air), simulator objects (representative of the thickness of the animal) and three dispositive standards of test that evaluate space resolution, resolution in low contrast and contrast-detail. The obtained images were analyzed and compared for a physicist and a radiologist medical veterinary. The results had shown that the examinations supply dose considered high for techniques used mainly for coxal. The equipment A, although to supply higher doses, presents the better images for the majority of the projections. However, the study indicates that there are not exactly reference levels, but these examinations must pass for improvement of quality of image (author)

  9. Examination of the Correlation Between Foot Morphology Measurements Using Pedography and Radiographic Measurements.

    Science.gov (United States)

    Inui, Kentaro; Ikoma, Kazuya; Imai, Kan; Ohashi, Suzuyo; Maki, Masahiro; Kido, Masamitsu; Hara, Yusuke; Oka, Yoshinobu; Fujiwara, Hiroyoshi; Kubo, Toshikazu

    Pedography provides excellent visualization of the footprint. However, the correlation between the footprint images and radiographic measures has not been thoroughly evaluated. Therefore, the objectives of our study were to examine the correlation between the pedography-based measures of foot morphology and radiographic measurements and to propose reference values for the diagnosis of flatfoot using footprint imaging. The plantar footprints of 100 right feet were photographed using a pedography standing platform. The sole and arch areas were measured to calculate the footprint index (FPI). The lateral talar-first metatarsal angle (LTM) and calcaneal pitch angle (CP) were measured on standing lateral radiographs, and the talonavicular coverage angle was measured on frontal radiographs. The Pearson moment correlation between the FPI and radiography-based measures was calculated. The area under the receiver operating characteristic curve was calculated using an LTM of <-4° as the identifying criterion of flatfoot. The sensitivity and specificity of FPI were calculated for LTM values <-4°. The FPI correlated with the LTM (y = -17.964 ± 52.644x, R = 0.588) and CP (y = 9.2304 ± 27.739x, R = 0.659) but not with the talonavicular coverage angle (y = 26.01 ± 15.78x, R = 0.207). The area under the receiver operating characteristic curve was 0.753, with a cutoff FPI of 0.208, yielding a sensitivity of 0.462 and specificity of 0.934 for flatfoot identification. Pedography could provide an easy screening tool for flatfoot, with an FPI cutoff of 0.208, yielding a specificity of 93.4%. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Protocol of radiographic examination of children in order to improve the radiation protection

    International Nuclear Information System (INIS)

    Milkovic, Dj.; Ranogajec-Komor, M.; Miljanic, S.

    2005-01-01

    Pulmonary radiograms are essential in the diagnostics of lung diseases of children and youth. Frontal and lateral chest radiographs are basic for radiological examination of the thorax. Plain radiographic findings and presumptive clinical diagnosis will determine the need for further imaging. To estimate the risk of various damages in children, in our earlier study we measured radiation doses received during radiological examination of thoracic organs using different thermoluminescent detectors (TLD) placed in different positions on the body. Results were obtained for 50 patients divided in groups by age. Although the evaluated risks were not alarming, taking into account the average annual number of patients, all patient protection measures should be carried out. It is important to note that X-ray examination should be performed only if detailed history is provided, that clinical and laboratory tests are complete, that a good, specialised children radiology department is available which employs well-trained staff and that an individual radiological approach to every child is assured.(author)

  11. First experience of electron microscopic and bacteriological examination of the prostate gland stones

    Directory of Open Access Journals (Sweden)

    I. V. Vinogradov

    2014-01-01

    Full Text Available The work is based on a study of prostate stones obtained by transurethral resection of the prostate in 5 patients with benign prostatic hyperplasia in combination with chronic calculous prostatitis. Stones have been investigated by scanning electron microscopy and X-ray microstructural analysis, as well as a comparative study of bacteriological swabs from the surface of the stones after ultrasonic treatment of stone and without it. Pretreatment ultrasound prostate stones before sowing on nutrient medium swabs improves bacteriological diagnosis, which may be due to the dispersion of biofilms and exit vegetative forms of bacteria from it. This feature can serve as ultrasound theoretical justification for its use to improve the efficiency of diagnosis of various forms of prostatitis.

  12. Study on image quality of radiograph in radiographic examination for circumferential welded joint. 1. Basic study on scattered radiation in double wall exposure technique

    International Nuclear Information System (INIS)

    Kato, Kiyoshi; Ooka, Norikazu.

    1997-01-01

    Wire type Image Quality Indicators (I. Q. I.) are usually used for the evaluation of the image quality of radiographs in radiographic examinations specified in the Japanese Industrial Standard (JIS). The relationship between the sensitivity of the Image Quality Indicator and the radiographic contrast in single wall exposure technique has already been well understood. However, the relationship in double wall exposure technique is still under discussion. As a result of the fundamental experiments using flat plates, it was found in this study that the image quality of radiograph depends on the ratio of scattered X-rays generated in the focus side test plate to transmitted X-rays, and that the ratio varies in inverse proportion to the distance between the flat plates. It was also shown that the simulation method based on the Compton Effect is effective in obtaining the ratio of scattered to transmitted X-rays in the double wall exposure technique for a pipe of more than 100 mm diameter. (author)

  13. Are chest radiographs justified in pre-employment examinations. Presentation of legal position and medical evidence based on 1760 cases

    International Nuclear Information System (INIS)

    Ladd, S.C.; Krause, U.; Ladd, M.E.

    2006-01-01

    The legal and medical basis for chest radiographs as part of pre-employment examinations (PEE) at a University Hospital is evaluated. The radiographs are primarily performed to exclude infectious lung disease. A total of 1760 consecutive chest radiographs performed as a routine part of PEEs were reviewed retrospectively. Pathologic findings were categorized as ''nonrelevant'' or ''relevant.'' No positive finding with respect to tuberculosis or any other infectious disease was found; 94.8% of the chest radiographs were completely normal. Only five findings were regarded as ''relevant'' for the individual. No employment-relevant diagnosis occurred. The performance of chest radiography as part of a PEE is most often not justified. The practice is expensive, can violate national and European law, and lacks medical justification. (orig.) [de

  14. A patient dose survey or femoral arteriogram diagnostic radiographic examinations using a dose-area product meter

    International Nuclear Information System (INIS)

    Thwaites, J.H.; Rafferty, M.W.; Gray, N.; Black, J.; Stock, B.

    1996-01-01

    We present a method for dealing with a complex radiographic procedure (which involves multiple radiographs and fluoroscopy) in an attempt to provide a simple way of calculating effective dose from which a general risk factor can be determined. A useful index of harm can be obtained by recording the number of radiographs in each region, and the fluoroscopy time, from which the effective dose may be easily calculated. A patient dose survey was carried out using a PTW diamentor for femoral arteriogram procedures in a large teaching hospital. The procedure involves fluoroscopy to the pelvic region to locate a guide wire and catheter, followed by a series of radiographs extending from the pelvic area to the feet to form a collage image of the entire arterial system. Radiographs are taken whilst a bolus of contrast media is injected into the arterial system. The measurements extend a continuing survey of doses for common diagnostic radiographic examinations which have previously included the simple examinations of lumbar spine, abdomen and pelvis. (Author)

  15. Upper gastrointestinal examinations: a radiographic study of clinically normal Beagle puppies

    International Nuclear Information System (INIS)

    Miyabayashi, T.; Morgan, J.P.

    1991-01-01

    A total of 24 upper gastrointestinal examinations were performed on four weanling beagle puppies over six weeks, using liquid barium (10 ml/kg body weight of 60 per cent w/v barium sulphate suspension] and barium food (8 g/kg of crushed kibble dog food and 7 ml/kg body weight of 60 per cent w/v barium sulphate suspension) as contrast media. The radiographic appearance was similar to that noted in adult dogs except for the consistent location of the pylorus on or near the midline. Duodenal pseudoulcers were seen more often with liquid barium and the caecal shadows were identified more often with the longer examination time with barium food. The stomach of the puppies appeared to have discriminatory emptying function; that is, semi-solid food was emptied from the stomach at a slower rate (210 to 450 minutes) than liquid (60 to 90 minutes). Solid meals emptied faster in puppies than in adult dogs. Dosages of 13 to 15 mg/kg body weight for the liquid barium examination and 14 g of ground kibble and 16 ml of barium sulphate suspension per m2 of body surface area for the barium food examination are suggested as more appropriate for contrast studies in puppies

  16. MRI reporting by radiographers: The construction of an objective structured examination

    International Nuclear Information System (INIS)

    Piper, K.J.; Buscall, K.L.

    2008-01-01

    Purpose: The aim was to construct a bank of general magnetic resonance imaging (MRI) investigations where good agreement was demonstrated between three independent radiological reports. The bank was subsequently to be used to assess radiographers' ability to accurately report at the end of an accredited programme; Postgraduate Certificate (PgC) Clinical Reporting (MRI-General Investigations). Method: Eighty-seven examinations (33 knee, 36 lumbar spine and 18 internal auditory meatus-IAM) were initially reported by two radiologists. Seventy-two of these examinations (25 knee, 29 lumbar spine and 18 IAM) were subsequently reported by a third radiologist. Interobserver agreement was assessed by estimating the total, positive and negative % agreement rates; and by use of the weighted or unweighted kappa values. Knee reports were analysed for meniscal tears, and degenerative meniscus (264 meniscal sites); ligament injury (ACL; PCL; MCI; and LCL; 132 ligament sites); bone bruise; effusion; fracture and/or osteochondral defect. Lumbar spine reports were analysed for disc morphology (bulge, protrusion, extrusion and/or annular tear-180 intervertebral disc levels); degenerative disc disease; Modic endplate changes; cord compression; spinal stenosis; nerve root involvement; vertebral collapse, primary tumour or metastases; and other incidental findings. IAM reports were analysed for acoustic neuroma and vascular loop. Results: Agreement in the knee reports varied mainly between moderate (κ = 0.46) for ligament injury to very good [almost perfect] (κ = 0.86) for meniscal tears, although agreement for degenerative meniscus was only fair (κ = 0.3). Variation in the lumbar spine reports ranged predominantly between moderate (κ = 0.54) for disc bulge/protrusion to fair (κ = 0.32) for Modic endplate changes to good [substantial] (κ = 0.79) for tumour/metastases. Agreement for the presence of acoustic neuroma was very good [almost perfect] (κ = 1.0). Forty cases

  17. Comparison of parameters characterizing lumbar lordosis in radiograph and photogrammetric examination of adults.

    Science.gov (United States)

    Drzał-Grabiec, Justyna; Truszczyńska, Aleksandra; Tarnowski, Adam; Płaszewski, Maciej

    2015-01-01

    The purpose of this study was to test validity of photogrammetry compared with radiography as a method of measuring the Cobb angle and the size of anterior-posterior spine curvatures in adults. The study included 50 volunteers, 23 men and 27 women whose mean age was 52.6 years. The average weight of the subjects was 81.3 kg, average body height was 172.0 cm, and the average body mass index was 27.4. Based on radiologic examination, the length and depth of lumbar lordosis were determined and the size of the Cobb angle of lumbar scoliosis. After the radiologic examination, a photogrammetric test was performed for each subject with the projection moire phenomenon. The Pearson correlation found statistically significant associations concerning the length of lordosis (P lordosis indicated a strong trend (P = .063). This study found that the moire method of photogrammetric measurement produced similar findings to radiographic measurements in determining size of the Cobb angle and the length of lumbar lordosis. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  18. Rate of duodenal-biliary reflux increases in patients with recurrent common bile duct stones: evidence from barium meal examination.

    Science.gov (United States)

    Zhang, Rongchun; Luo, Hui; Pan, Yanglin; Zhao, Lina; Dong, Junqiang; Liu, Zhiguo; Wang, Xiangping; Tao, Qin; Lu, Guohua; Guo, Xuegang

    2015-10-01

    Stone recurrence is a common late adverse event after ERCP in patients with common bile duct stones (CBDS). Duodenal-biliary reflux (DBR) is considered a major cause of CBDS recurrence. However, specific evidence is still lacking. To investigate the DBR rate in patients with recurrent CBDS after ERCP. A prospective case-control study. A tertiary center. During follow-up, patients with a history of either recurrent CBDS (recurrence group) or nonrecurrent CBDS (control group) were invited to participate in the study. All patients had previously undergone successful CBDS removal by ERCP. Patients in the control group were matched with the recurrence group by age and gender in a 1:1 ratio. Patients with gallbladder stones, hepatolithiasis, remnant CBDS, CBD strictures, or stents were excluded. Standard barium meal examination, MRCP, and enhanced abdominal CT. DBR. Thirty-two patients with a history of recurrent CBDS and 32 matched control subjects were enrolled. Baseline characteristics and parameters regarding the first ERCP were comparable between the 2 groups. The DBR rate was significantly higher in the recurrent than in the control group (68.8% vs 15.6%, P < .001). Multivariate analysis indicated that DBR (OR, 9.59; 95% CI, 2.65-34.76) and acute distal CBD angulation (OR, 5.48; 95% CI, 1.52-19.78) were independent factors associated with CBDS recurrence. DBR rates in patients with no, single, or multiple recurrences were 15.6%, 60.9%, and 88.9%, respectively (P < .001). Intrahepatic bile duct reflux was more common in patients with multiple recurrences. Small sample size. DBR is correlated with CBDS recurrence in patients who had previously undergone ERCP. DBR and acute distal CBD angulation are 2 independent risk factors related to stone recurrence. ( NCT02329977.) Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  19. Phantom development for radiographic image optimization of chest, skull and pelvis examination for nonstandard patient

    International Nuclear Information System (INIS)

    Pina, D.R.; Duarte, S.B.; Ghilardi Netto, T.; Morceli, J.

    2009-01-01

    The construction of the adapted patient equivalent phantom (APEP) to simulate the X-ray scattering and absorption by chest, skull and pelvis of nonstandard patient in conventional radiographic equipment is presented. This APEP system is associated to the pre-existing realistic-analytic phantom (RAP) [Pina, D.R., Duarte, S.B., Ghilardi Netto, T., Trad, C. S., Brochi, M.A.C., Oliveira, S.C. de, 2004. Optimization of standard patient radiographic images for chest, skull and pelvis exams in conventional X-ray equipment. Phys. Med. Biol. 49, N215-N226] forming the coupled phantom (RAP-APEP), which is used to establish an optimization process of radiographic images of chest, skull and pelvis for nonstandard patients. A chart of the optimized radiographic technique is established covering a wide range of nonstandard patient thickness, and offering a dose reduction in comparison with those techniques currently used. Different validation processes were applied to confirm the improving of the radiographic image quality when techniques of the established chart are used

  20. Examination of the constancy of the medium optical density of conventional chest radiographs

    International Nuclear Information System (INIS)

    Stieve, F.E.; Rupp, N.; Niederhofer, F.; Gfirtner, H.

    2002-01-01

    Purpose: To determine whether the medium optical density of conventional chest radiographs is constant. Materials and Methods: 47 PA chest radiographs were digitized to measure the optical density and its dynamic range of normal and pathologically altered lungs. Results: For constant exposure factors and a correctly positioned region of interest, the medium optical density deviates only minimal despite differences in AP chest diameter, entry dose and dynamic range, and is largely independent of the pathologic pulmonary findings. Conclusion: Digitization of the radiograph enables the determination of the physical parameters used to operate the imaging system, such as medium optical density, image contrast, image latitude and density distribution, in accordance to the guidelines of the German Medical Association. If the region of interest encompasses the clinically relevant region of the lung, the measured value of the optical density corresponds with only minor variation to the average value of the entire lung region. (orig.) [de

  1. Radiographic positioning

    International Nuclear Information System (INIS)

    Eisenberg, R.L.; Dennis, C.A.; May, C.

    1989-01-01

    This book concentrates on the routine radiographic examinations commonly performed. It details the wide variety of examinations possible and their place in initial learning and in the radiology department as references for those occasions when an unusual examination is requested. This book provides information ranging from basic terminology to skeletal positioning to special procedures. Positions are discussed and supplemented with a picture of a patient, the resulting radiograph, and a labeled diagram. Immobilization and proper shielding of the patient are also shown

  2. Evaluation of underexposed conventional radiographs after digitization

    International Nuclear Information System (INIS)

    Wenz, W.

    1993-01-01

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.) [de

  3. Radiographic Test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H.J; Yang, S.H. [Korea Electric Power Research Institute, Taejon (Korea)

    2002-07-01

    This report contains theory, procedure technique and interpretation of radiographic examination and written for whom preparing radiographic test Level II. To determine this baseline of technical competence in the examination, the individual must demonstrate a knowledge of radiography physics, radiation safety, technique development, radiation detection and measurement, facility design, and the characteristics of radiation-producing devices and their principles of operation. (author) 98 figs., 23 tabs.

  4. Negative radiographic examinations: Evaluation of risks from exposure; Examenes radiograficos negativos evaluacion de los riesgos por su exposicion

    Energy Technology Data Exchange (ETDEWEB)

    Frometa Suarez, I; Jerez Vegueria, S F [Departamento Higiene de las Radiociones, Inst. de Medicina del Trabajo, La Habana (Cuba)

    1997-11-01

    The individual dose of radiation per radiological diagnosis is decreasing, which is an important contribution for the number of exposed population. This is a result of a completed study presented by the Manuel Fajardo Surgery Clinic of the Municipality of Havana, which evaluated the behaviour of the negative radiological examinations and their contribution to the collective dose as well as the associated detriment. 486 cases with radiographic examinations are reported over a period of four months. The information on individual cases is classified by type of radiographic examination and whether the outcome of the examination was positive or negative, the absorbed doses per organ and irradiated tissue, dose equivalent, collective and effective doses. The probability of the occurrence of a fatal cancer and associated genetic damage due to the examinations is also considered. 41% of the examinations performed were negative, with a collective dose of 11.35 manSv and 52.9 % of the total doses contributed for all the radiological examinations of the population studied. 7 refs, 3 tabs.

  5. An investigation into techniques for reducing doses from neo-natal radiographic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Wraith, C.M.; Martin, C.J. [Aberdeen Royal Hospitals NHS Trust (United Kingdom). Dept. of Bio-Medical Physics and Bio-Engineering; Stockdale, E.J.N.; McDonald, S.; Farquhar, B. [Royal Aberdeen Children`s Hospital (United Kingdom)

    1995-10-01

    A survey of radiation doses received by infants having radiography in a neo-natal unit was undertaken at Aberdeen Maternity Hospital. Options for dose reduction recommended by the CEC Lake Starnberg Group were investigated. Techniques were implemented for clinical evaluation after assessments of image quality with test objects and phantoms. Clinical image quality of radiographs was evaluated by paediatric radiologists using CEC criteria. Results revealed a clear relationship between entrance dose and patient weight, indicating that reference doses for infants could be linked to weight. (author).

  6. Comparison between three radiographic techniques for examination of the temporomandibular joints in juvenile rheumatoid arthritis

    International Nuclear Information System (INIS)

    Larheim, T.A.

    1981-01-01

    Comparison between orthopantomography, conventional radiography and lateral tomography for diagnosing arthritic lesions in the temporomandibular joints of 42 children with juvenile rheumatoid arthritis showed that each method seems to have diagnostic limitations. Concordance values of about 70 per cent were obtained. Most often destructive lesions of both the mandibular head and the fossa were observed at tomography. Secondary arthrosis, particularly sclerosis of the fossa, was most often diagnosed at conventional radiography. A combination of radiographic techniques seems to be most reliable for diagnosing arthritic joint abnormalities in children. (Auth.)

  7. Correlations between radiographic, magnetic resonance and histological examinations on the degeneration of human lumbar intervertebral discs

    Directory of Open Access Journals (Sweden)

    Delio Eulalio Martins

    Full Text Available CONTEXT AND OBJECTIVE: There is controversy regarding which imaging method is best for identifying early degenerative alterations in intervertebral discs. No correlations between such methods and histological finds are presented in the literature. The aim of this study was to correlate the thickness of intervertebral discs measured on simple radiographs with the degree of degeneration seen on magnetic resonance images and the histological findings relating to nerve ends inside the discs. DESIGN AND SETTING: Cross-sectional correlation study on the lumbar spines of human cadavers, at Universidade Federal de São Paulo (Unifesp, São Paulo, Brazil. METHODS: Ten lumbar spinal columns were extracted from human cadavers and subjected to magnetic resonance imaging and simple radiography. They were classified according to the degree of disc degeneration seen on magnetic resonance, and the thickness of the discs was measured on radiographs. The intervertebral discs were then extracted, embedded in paraffin and analyzed immunohistochemically with protein S100, and the nerve fibers were counted and classified. RESULTS: No correlation was observed between the thickness of the intervertebral discs and the degree of degeneration seen on magnetic resonance images. Only the uppermost lumbar discs (L1/L2 and L2/L3 presented a correlation between their thickness and type I and IV nerve endings. CONCLUSION: Reduced disc thickness is unrelated to increased presence of nerve ends in intervertebral discs, or to the degree of disc degeneration.

  8. Radiation doses and risks to neonates undergoing common radiographic examinations in the neonatal intensive care unit

    International Nuclear Information System (INIS)

    McParland, B.J.; Lee, R.

    1996-01-01

    Neonates in the-Neonatal Intensive Care Unit (NICU) can receive large numbers of radiographs owing to the clinical conditions they may present. More neonatal radiation dosimetry data are required for three fundamental reasons: (1.) to aid in the establishment of reference dose levels for interinstitutional comparisons; (2.) to improve childhood cancer risk estimates following neonatal exposure; and (3.) to indicate appropriate directions for dose reduction. This paper describes an investigation of two different NICU radiological techniques with significantly different neonate doses. While patient-matched images taken with both techniques were assessed in a blind review, this component of the study is beyond the scope of this paper and is not discussed here. (author)

  9. Optimising radiographic bitewing examination to adult and juvenile patients through the use of anthropomorphic phantoms

    International Nuclear Information System (INIS)

    Dauer, L. T.; Branets, I.; Stabulas-Savage, J.; Quinn, B.; Miodownik, D.; Dauer, Z. L.; Colosi, D.; Hershkowitz, D.; Goren, A.

    2014-01-01

    Four anthropomorphic phantoms (an adult male, an adult female, a 10-y-old child and a 5-y-old child) were exposed to bitewing radiographs at film and digital settings using both rectangular and round collimation. Optically stimulated dosemeters were used. For children, average organ doses were <40 μGy and the organs with the highest doses were the salivary glands, parotid, oral mucosa, skin and extrathoracic airway. For adults, average organ doses were <200 μGy. Highest adult doses were to the salivary glands, oral mucosa and skin. Effective doses ranged from 1.5 to 1.8 μSv for children and from 2.6 to 3.6 μSv for adults when optimised technique factors were employed, including digital receptors, rectangular collimation, size-appropriate exposure times and proper clinical judgment. Optimised doses were a fraction of the natural daily background exposure. Therefore, predictions of hypothetical cancer incidence or detriment in patient populations exposed to such low doses are highly speculative and should be discouraged. (authors)

  10. Measurements of radiation dose to patients undergoing some common radiographic x-ray examinations in Wad Madani hospitals

    International Nuclear Information System (INIS)

    Mohammedzein, T. S.

    2009-12-01

    The aim of this study was to assess patient doses in most common radiographic x-ray examinations in Wad Madani hospitals of Al Gazera State. The examination parameters of 388 radiographs were used to calculate the Entrance Surface Air Kerma (ESAK) of patients undergoing skull (AP and LAT), chest (PA), pelvis (AP), abdomen (AP) and lumbar spin (AP and LAT) in six major hospitals. Hospital mean ESAKs estimated range from 0.0729-0.69 mGy for chest PA, 0.338-6.64 mGy for skull PA, 0.195-5.8 mGy for skull LAT, 0.595-3.42 mGy for pelvis AP, 0.772-6.31 mGy for lumbar spine AP, 2.1-15.2 mGy for lumbar spine LAT and 0.742-5.79 mGy for abdomen. This data will be useful for the formulation of national reference levels as recommended by International Atomic Energy Agency (IAEA). (Author)

  11. Optimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations

    Directory of Open Access Journals (Sweden)

    Soo-Foon Moey

    2018-01-01

    Full Text Available IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization involved ninety physically abled patients aged between 20 to 60 years and weighed between 60 and 80 kilograms for four common digital radiographic examinations. Kerma X_plus, DAP meter was utilized to measure the entrance surface dose (ESD while effective dose (ED was estimated using CALDose_X 5.0 Monte Carlo software. The second phase, an experimental study utilized an anthropomorphic phantom (PBU-50 and Leeds test object TOR CDR for relative comparison of image quality. For the optimization phase, the imaging parameters with acceptable image quality and lowest ESD from the experimental study was related to patient’s body thickness. Image quality were evaluated by two radiologists using the modified evaluation criteria score lists. ResultsSignificant differences were found for image quality for all examinations. However significant difference for ESD were found for PA chest and AP abdomen only. The ESD for three of the examinations were lower than all published data. Additionally, the ESD and ED obtained for all examinations were lower than that recommended by radiation regulatory bodies. ConclusionOptimization of image quality and dose was achieved by utilizing an appropriate tube potential, calibrated automatic exposure control and additional filtration of 0.2mm copper.

  12. Nationwide survey of dental radiographic examination and estimation of collective effective dose in Japan, 1999

    International Nuclear Information System (INIS)

    Iwai, Kazuo; Satomi, Chieko; Kawashima, Shoji; Hashimoto, Koji; Nishizawa, Kanae; Maruyama, Takashi

    2005-01-01

    A nationwide survey of dental X-ray examination in Japan was performed in 1999, and the effective exposure dose due to the dental X-ray examination was estimated. In Japan, most dental X-ray equipment are used at a tube voltage of 60 kV and a tube current of 10 mA. Dental film in speed group D is most frequently used for dental X ray examination. Fifty percent or more of dental clinics processed the films automatically. Seventy-five percent of dental clinics performed dental X-ray examinations in a separate X-ray room. The number of dental X-ray examinations in 1999 in Japan was estimated to be 82,301,000 for intra-oral radiography and 12,336,000 for panoramic radiography. The collective effective exposure dose in 1999 was estimated at 905.5 man·Sv, for intra-oral radiography and 128.9 man·Sv for panoramic radiography. (author)

  13. Radiation risk assessment in neonatal radiographic examinations of the chest and abdomen: a clinical and Monte Carlo dosimetry study

    International Nuclear Information System (INIS)

    Makri, T; Yakoumakis, E; Papadopoulou, D; Gialousis, G; Theodoropoulos, V; Sandilos, P; Georgiou, E

    2006-01-01

    Seeking to assess the radiation risk associated with radiological examinations in neonatal intensive care units, thermo-luminescence dosimetry was used for the measurement of entrance surface dose (ESD) in 44 AP chest and 28 AP combined chest-abdominal exposures of a sample of 60 neonates. The mean values of ESD were found to be equal to 44 ± 16 μGy and 43 ± 19 μGy, respectively. The MCNP-4C2 code with a mathematical phantom simulating a neonate and appropriate x-ray energy spectra were employed for the simulation of the AP chest and AP combined chest-abdominal exposures. Equivalent organ dose per unit ESD and energy imparted per unit ESD calculations are presented in tabular form. Combined with ESD measurements, these calculations yield an effective dose of 10.2 ± 3.7 μSv, regardless of sex, and an imparted energy of 18.5 ± 6.7 μJ for the chest radiograph. The corresponding results for the combined chest-abdominal examination are 14.7 ± 7.6 μSv (males)/17.2 ± 7.6 μSv (females) and 29.7 ± 13.2 μJ. The calculated total risk per radiograph was low, ranging between 1.7 and 2.9 per million neonates, per film, and being slightly higher for females. Results of this study are in good agreement with previous studies, especially in view of the diversity met in the calculation methods

  14. Radiation risk assessment in neonatal radiographic examinations of the chest and abdomen: a clinical and Monte Carlo dosimetry study

    Science.gov (United States)

    Makri, T.; Yakoumakis, E.; Papadopoulou, D.; Gialousis, G.; Theodoropoulos, V.; Sandilos, P.; Georgiou, E.

    2006-10-01

    Seeking to assess the radiation risk associated with radiological examinations in neonatal intensive care units, thermo-luminescence dosimetry was used for the measurement of entrance surface dose (ESD) in 44 AP chest and 28 AP combined chest-abdominal exposures of a sample of 60 neonates. The mean values of ESD were found to be equal to 44 ± 16 µGy and 43 ± 19 µGy, respectively. The MCNP-4C2 code with a mathematical phantom simulating a neonate and appropriate x-ray energy spectra were employed for the simulation of the AP chest and AP combined chest-abdominal exposures. Equivalent organ dose per unit ESD and energy imparted per unit ESD calculations are presented in tabular form. Combined with ESD measurements, these calculations yield an effective dose of 10.2 ± 3.7 µSv, regardless of sex, and an imparted energy of 18.5 ± 6.7 µJ for the chest radiograph. The corresponding results for the combined chest-abdominal examination are 14.7 ± 7.6 µSv (males)/17.2 ± 7.6 µSv (females) and 29.7 ± 13.2 µJ. The calculated total risk per radiograph was low, ranging between 1.7 and 2.9 per million neonates, per film, and being slightly higher for females. Results of this study are in good agreement with previous studies, especially in view of the diversity met in the calculation methods.

  15. Survey of patient doses from conventional diagnostic radiographic examinations in Syria

    International Nuclear Information System (INIS)

    Kharita, M. H.; Khedr, M. S.; Wannus, K. M.

    2010-01-01

    The aim of this study is to evaluate radiation doses received by adult patients undergoing eight routine common types of X-ray examination in Syria. These types cover chest PA, lumbar spine PA, lumbar spine LAT, urography, abdomen, pelvis and hip, head and shoulder. This work consisted of measurements for 926 X-ray examinations for patients in 26 governmental hospitals. The mean and third quartile of the dose area product (DAP) to each patient per examination have been measured. The corresponding average effective doses have been computed from the DAP measurement for each examination using NRPP X-Dose software. Comparison of the results was done with those from similar surveys published by the United Nation Scientific Committee on the Effects of Atomic Radiation (UNSCEAR, 2000, 2007). The present measurements will provide a useful baseline to establish, for the first time, national diagnostic reference levels. These results can be used in the future to evaluate the collective dose to the population from medical exposure and the radiation risks from the various radiological procedures. (authors)

  16. Test of a new gonad shield in radiographic hip joint examinations of sucklings and infants

    International Nuclear Information System (INIS)

    Bronsch, T.

    1977-01-01

    Preparation and application of a shield consisting of lead rubber are described. Using the shield, a considerable decrease of radiation exposure to male and female infants could be achieved. Therefore it is recommended for application in mass examinations of hip joints. (author)

  17. Recent technical developments in radiographic and ultrasonic examinations of the mammary glands

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, M

    1981-05-01

    Apart from the improved film-foil combinations the major innovation in mammography is the scanning technique which enables high-quality mammograms to be made especially of thicker objects of higher density. It has already become the method of choice for screening examinations in the major preventive-care centres for breast cancer. Magnification mammography, on the other hand, has some technical drawbacks and is only used as a supplementary technique of examination. Even though it has not yet reached technical maturity, sonography of the mammary glands already plays an important role as an auxiliary or complementary technique, especially to clear up ambiguous palpatory or mammographic findings. It has only limited value in early detection of breast cancer and should therefore be used only as a supplementary technique.

  18. An augmented audit program for assuring radiation safety during radiographic examination operations

    International Nuclear Information System (INIS)

    Jervey, R.A. Jr.; Papin, P.J.

    1993-01-01

    Auditing a gamma radiography program is required as part of the authorizing license. Checklists and cursory reviews are the typical approach to addressing program requirements. A more proactive approach is recommended. The audit program described was prepared for a specific set of operating conditions but can be applied to any given program. Improvements in the effectiveness of the radiography safety program can be made with additional examination and emphasis on direct observation of licensed activities

  19. Value of systematic post mortem radiographic examinations of fetuses - 400 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kalifa, G.; Sellier, N.; Barbet, J.P.; Labbe, F.; Houette, A.

    1989-01-01

    A retrospective study of 400 cases of fetal deaths has been carried out to assess the value of systematic post mortem radiological examination. Apart from general diagnosis purpose, special attention was given to the assessment of bone age and mineralization. The results were correlated with the clinical, U.S., chromosomal and pathological data. Computerized analysis of our information show the following results: (1) The radiological examination was valuable for the final diagnosis in 13.5% of cases. (2) It brings additional information in 34.5% of cases. (3) It had no diagnostic value in 52%. Furthermore several points deserve attention such as apparition of teeth (21 weeks), calcaneum (24 weeks). Major osteoporosis was always associated with a constitutional bone disease or an infectious process. An excessive length of the upper limbs (12) was seen in 11 cases of anencephaly. We suggest that a radiological examination should not be routinely performed, when the diagnosis is otherwise obvious, but should be considered in the presence of dwarfism, or other limb abnormalities and when the gestational age is uncertain. The films provide essential information especially for further genetic counselling.

  20. Value of systematic post mortem radiographic examinations of fetuses - 400 cases

    International Nuclear Information System (INIS)

    Kalifa, G.; Sellier, N.; Barbet, J.P.; Labbe, F.; Houette, A.

    1989-01-01

    A retrospective study of 400 cases of fetal deaths has been carried out to assess the value of systematic post mortem radiological examination. Apart from general diagnosis purpose, special attention was given to the assessment of bone age and mineralization. The results were correlated with the clinical, U.S., chromosomal and pathological data. Computerized analysis of our information show the following results: (1) The radiological examination was valuable for the final diagnosis in 13.5% of cases. (2) It brings additional information in 34.5% of cases. (3) It had no diagnostic value in 52%. Furthermore several points deserve attention such as apparition of teeth (21 weeks), calcaneum (24 weeks). Major osteoporosis was always associated with a constitutional bone disease or an infectious process. An excessive length of the upper limbs (12) was seen in 11 cases of anencephaly. We suggest that a radiological examination should not be routinely performed, when the diagnosis is otherwise obvious, but should be considered in the presence of dwarfism, or other limb abnormalities and when the gestational age is uncertain. The films provide essential information especially for further genetic counselling. (orig./MG)

  1. Performance of X-ray equipment used for conventional radiographic examinations of children

    International Nuclear Information System (INIS)

    Lacerda, Marco A.S.; Silva, Teogenes A. da; Khoury, Helen J.

    2009-01-01

    The performance of X-ray equipment that are used for conventional X-ray examinations of children in four hospitals of Belo Horizonte, Brazil, was evaluated. The methodology proposed by the Brazilian authority for radiation protection in diagnostic radiology was adopted. The performance tests were carried out in six X-ray machines and they consisted of measurements and determination of the X-ray tube output, linearity and constancy of radiation output, accuracy and reproducibility of the exposure time and tube potential, half-value layer (HVL), light field / X-ray field alignment and accuracy of the X-ray field indicator. It was observed that only one hospital had the suitable equipment for X-ray examinations of children. Results showed that all six equipment of the four hospitals presented unsatisfactory performance in some quality control tests. Only for some combinations of the exposure parameters, generally employed in pediatric X-ray examinations, some equipment complied with the authority requirements. (author)

  2. Radiation doses and risks to neonates undergoing radiographic examinations in intensive care units in Tunisia

    Directory of Open Access Journals (Sweden)

    Abir Bouaoun

    2015-12-01

    Full Text Available Purpose: To assess the radiation doses to neonates from diagnostic radiography in order to derive the local diagnostic reference levels (LDRLs for optimisation purposes.Methods: This study was carried out in the neonatal intensive care units (NICU of  two hospitals in Tunis. 134 babies, with weights ranging from 635 g to 6680 g, performed chest-abdomen X-ray examinations. Neonates were categorized into groups of birth weight. For each X-ray examination, patient data and exposure parameters were recorded. Dose area product (DAP was measured and entrance surface dose (ESD was estimated. Effective dose was calculated from the Monte Carlo simulation software PCXMC.Results: DAP values increased with neonatal weight and demonstrated a wide variation (5.0 - 43.0 mGy.cm2, mean 23.4 mGy.cm2 for patient weight from 600 g to 4000 g. A wide variation was also observed for ESD (14 - 93 μGy, mean 55.2 μGy. The LDRLs expressed in term of DAP were estimated to be 17.6 mGy.cm2 and 29.1 mGy.cm2 for the first and the second NICU, respectively. In terms of effective dose, the average value was about 31.6 μSv per single radiological examination. The results show the necessity to use a standardized protocol with high voltage technique combined to lower current time product (mAs values and an adapted collimation which could lead to further reductions in the neonatal doses. Conclusion: This study presents the LDRLs and the effective doses for neonates in two NICUs and demonstrates the necessity to optimize patient protection for this category of patient.

  3. Absorbed doses and energy imparted from radiographic examination of velopharyngeal function during speech

    International Nuclear Information System (INIS)

    Isberg, A.; Julin, P.; Kraepelien, T.; Henrikson, C.O.

    1989-01-01

    Absorbed doses of radiation were measured by thermoluminescent dosimeters (TLDs) using a skull phantom during simulated cinefluorographic and videofluorographic examination of velopharyngeal function in frontal and lateral projections. Dosages to the thyroid gland, the parotid gland, the pituitary gland, and ocular lens were measured. Radiation dosage was found to be approximately 10 times less for videofluoroscopy when compared with that of cinefluoroscopy. In addition, precautionary measures were found to reduce further the exposure of radiation-sensitive tissues. Head fixation and shielding resulted in dose reduction for both video- and cinefluoroscopy. Pulsing exposure for cinefluoroscopy also reduced the dosage

  4. Estimates of diagnostic reference levels for common radiographic x-ray examinations in some sudanese hospitals

    International Nuclear Information System (INIS)

    Awad, Ezdehar Mohammed Satti.

    2016-03-01

    The objective of this study were to estimate patient dose in some common diagnostic x-ray examinations in Sudan with the aim to propose national diagnostic reference levels (DRLs). Radiation doses were estimated for the patients in 23 public hospitals in different town in Sudan (Wad-Madani, Kasala, Atbara Al obaid, Al nhod, Khartoum). Entrance surface air kerma (ESAK) was estimated in a three steps protocol: First, x-ray unit output Y (d) was measured at a distance at a distance (d) for different peak tube voltages and tube loading (mAs). Next, incident air kerma (k) was calculated from Y (d) using inverse square law combined with patient exposure factors. ESAK was calculated from k using backscatter factor, B. Mean ESAK values were comparable to those reported in other countries and are below reference dose levels. The estimated mean ESAK values were: 0.4, 1.9, 1.8, 3.2, 2.4, 3.5, and 8.4 mGy for chests . The estimated mean ESAK values were 0.4, 1.9, 1.8, 3.2, 2.4, 3,5, and 8.4 mGy for chest PA, Skull AP/PA, Skull LAT, Abdomen Pelvis AP, Lumber Spine AP and Lumber Spine LAT examination respectively. The results are used for dose optimization and to propose national diagnostic reference levels. (Author)

  5. Examining the Causes and Consequences of Short-Term Behavioral Change during the Middle Stone Age at Sibudu, South Africa.

    Directory of Open Access Journals (Sweden)

    Nicholas J Conard

    Full Text Available Sibudu in KwaZulu-Natal (South Africa with its rich and high-resolution archaeological sequence provides an ideal case study to examine the causes and consequences of short-term variation in the behavior of modern humans during the Middle Stone Age (MSA. We present the results from a technological analysis of 11 stratified lithic assemblages which overlie the Howiesons Poort deposits and all date to ~58 ka. Based on technological and typological attributes, we conducted inter-assemblage comparisons to characterize the nature and tempo of cultural change in successive occupations. This work identified considerable short-term variation with clear temporal trends throughout the sequence, demonstrating that knappers at Sibudu varied their technology over short time spans. The lithic assemblages can be grouped into three cohesive units which differ from each other in the procurement of raw materials, the frequency in the methods of core reduction, the kind of blanks produced, and in the nature of tools the inhabitants of Sibudu made and used. These groups of assemblages represent different strategies of lithic technology, which build upon each other in a gradual, cumulative manner. We also identify a clear pattern of development toward what we have previously defined as the Sibudan cultural taxonomic unit. Contextualizing these results on larger geographical scales shows that the later phase of the MSA during MIS 3 in KwaZulu-Natal and southern Africa is one of dynamic cultural change rather than of stasis or stagnation as has at times been claimed. In combination with environmental, subsistence and contextual information, our high-resolution data on lithic technology suggest that short-term behavioral variability at Sibudu can be best explained by changes in technological organization and socio-economic dynamics instead of environmental forcing.

  6. Examining the Causes and Consequences of Short-Term Behavioral Change during the Middle Stone Age at Sibudu, South Africa.

    Science.gov (United States)

    Conard, Nicholas J; Will, Manuel

    2015-01-01

    Sibudu in KwaZulu-Natal (South Africa) with its rich and high-resolution archaeological sequence provides an ideal case study to examine the causes and consequences of short-term variation in the behavior of modern humans during the Middle Stone Age (MSA). We present the results from a technological analysis of 11 stratified lithic assemblages which overlie the Howiesons Poort deposits and all date to ~58 ka. Based on technological and typological attributes, we conducted inter-assemblage comparisons to characterize the nature and tempo of cultural change in successive occupations. This work identified considerable short-term variation with clear temporal trends throughout the sequence, demonstrating that knappers at Sibudu varied their technology over short time spans. The lithic assemblages can be grouped into three cohesive units which differ from each other in the procurement of raw materials, the frequency in the methods of core reduction, the kind of blanks produced, and in the nature of tools the inhabitants of Sibudu made and used. These groups of assemblages represent different strategies of lithic technology, which build upon each other in a gradual, cumulative manner. We also identify a clear pattern of development toward what we have previously defined as the Sibudan cultural taxonomic unit. Contextualizing these results on larger geographical scales shows that the later phase of the MSA during MIS 3 in KwaZulu-Natal and southern Africa is one of dynamic cultural change rather than of stasis or stagnation as has at times been claimed. In combination with environmental, subsistence and contextual information, our high-resolution data on lithic technology suggest that short-term behavioral variability at Sibudu can be best explained by changes in technological organization and socio-economic dynamics instead of environmental forcing.

  7. Assessment of ureterovesical jet dynamics in obstructed ureter by urinary stone with color Doppler and duplex Doppler examinations.

    Science.gov (United States)

    Jandaghi, Ali Babaei; Falahatkar, Siavash; Alizadeh, Ahmad; Kanafi, Alireza Rajabzadeh; Pourghorban, Ramin; Shekarchi, Babak; Zirak, Amin Keshavarz; Esmaeili, Samaneh

    2013-04-01

    This study was designed to evaluate ureterovesical jet dynamics in obstructed ureter and to compare it with those of contralateral unobstructed side. Forty-six patients with diagnosis of ureteral stone, based on imaging findings in computed tomography were enrolled in this study. The gray-scale ultrasound exam from both kidneys and urinary bladder was performed. Then, ureterovesical jet characteristics including ureteral jet frequency, duration and peak velocity were assessed by color Doppler and duplex Doppler studies in both obstructed and unobstructed ureters by a radiologist, 15-30 min after oral hydration with 750-1,000 mL of water. When compared with contralateral normal side, the ureterovesical jet in obstructed ureter showed less frequency (0.59 vs. 3.04 jets/min; P < 0.05), shorter duration (1.24 vs. 5.26 s; P < 0.05) and lower peak velocity (5.41 vs. 32.09 cm/s; P < 0.05). The cut-off points of 1.5 jets/min, 2.5 s and 19.5 cm/s for difference of ureteral jet frequency, duration and peak velocity between obstructed and contralateral normal ureters yielded sensitivities of 97.8, 95.6 and 100 % and specificities of 87, 87.9 and 97.8 %, respectively for diagnosis of ureteral obstruction. Given the safety of Doppler study and significant differences in flow dynamics of obstructed versus unobstructed ureters, our findings demonstrated the utility of Doppler ultrasound examination as a useful adjunct to gray-scale ultrasound by improving the accuracy of ultrasound exam in diagnosis of ureteral obstruction.

  8. Urethral obstruction from dislodged bladder Diverticulum stones: a case report

    Directory of Open Access Journals (Sweden)

    Okeke Linus I

    2012-11-01

    Full Text Available Abstract Background Secondary urethral stone although rare, commonly arises from the kidneys, bladder or are seen in patients with urethral stricture. These stones are either found in the posterior or anterior urethra and do result in acute urinary retention. We report urethral obstruction from dislodged bladder diverticulum stones. This to our knowledge is the first report from Nigeria and in English literature. Case presentation A 69 year old, male, Nigerian with clinical and radiological features of acute urinary retention, benign prostate enlargement and bladder diverticulum. He had a transurethral resection of the prostate (TURP and was lost to follow up. He re-presented with retained urethral catheter of 4months duration. The catheter was removed but attempt at re-passing the catheter failed and a suprapubic cystostomy was performed. Clinical examination and plain radiograph of the penis confirmed anterior and posterior urethral stones. He had meatotomy and antegrade manual stone extraction with no urethra injury. Conclusions Urethral obstruction can result from inadequate treatment of patient with benign prostate enlargement and bladder diverticulum stones. Surgeons in resource limited environment should be conversant with transurethral resection of the prostate and cystolithotripsy or open prostatectomy and diverticulectomy.

  9. Evaluation of levels of exposure of adult patients from common radiographic examinations in the Russian Federation in 2009–2014

    Directory of Open Access Journals (Sweden)

    A. V. Vodovatov

    2017-01-01

    Full Text Available Diagnostic reference levels are the main and the most effective tools of optimization of the radiation protection of patients from medical exposure. Diagnostic reference levels should be established based on the results of dedicated dose surveys, allowing evaluating typical patient dose distributions in a selected dose quantity for the selected X-ray examinations. The aim of the current study was to assess the distributions of typical effective doses in representative Russian regions. Materials and methods: Typical patient effective doses for the 13 most common radiographic X-ray examinations were collected in 203 X-ray rooms in 101 hospitals in six regions of Russian Federation in 2009–2014. A differentiated approach was used for the estimation of the typical effective doses depending on the image acquisition technology. Effective doses were estimated using «EDEREX» (Russia computational software. Results and discussion: Results of the dose data analysis indicate the lack of significant differences between the distributions of the typical effective doses between the selected regions, allowing merging the regional samples and further evaluating the pooled (joint sample. A significant ratio of maximum to minimum (up to two orders of magnitude due to a presence of X-ray units with abnormally high and low typical effective doses was observed for all 13 selected X-ray examinations. Abnormally high typical effective doses can be explained by performing the examinations using high values of tube current-time product (150–600 mAs on a maximum field size (up 40×40 cm. Removal of the typical effective doses below 5%-percentile and above 95%-percentile of typical effective dose distributions for all examinations would result in a reduction of a mean effective dose by up to 30% and reduction of a 75%-percentile of the distributions by up to 15%. No significant differences between the distributions of TED for analogue and digital X-ray units were

  10. Do stone size and impaction influence therapeutic approach to proximal ureteral stones?

    Directory of Open Access Journals (Sweden)

    Radulović Slobodan

    2009-01-01

    Full Text Available Background/Aim. Primary therapeutic approach to lumbar ureteral stones is still contraversial. The aim of the study was to investigate the influence of stone impaction and size on the effectiveness of proximal ureteral stone lithotripsy. Methods. A total of 123 patients with proximal ureteral stones were investigated in this prospective study performed in a 10- month period. The patients were divided into the group I - 86 patients treated with extracorporeal shock wave lithotripsy (ESWL and the group II - 37 patients treated with 'Swiss' Lithoclast. In the group I, 49 stones (57% were classified as impacted, while 20 stones (23.3% were larger than 100 mm2. In the group II, 26 stones (70.3% were impacted, and 11 stones (29.7% were larger than 100 mm2. Stones were defined as impacted by the radiographic, echosonographic as well as endoscopic findings in the group II of patients. Stone size was presented in mm2. Chemical composition of stones were almost the same in both groups of the patients. Results. Generally, there was no statistically significant difference in the treatment success between the groups. However, stones larger than 100 mm2 were statistically more successfully treated endoscopically, while there was no statistical difference in the treatment success of impacted stones between these two groups. Conclusion. ESWL can by considered as primary first therapeutic approach in treatment of all proximal ureteral stones except for stones larger than 100 mm2 that should primarily be treated endoscopically.

  11. The use of radiological guidelines to achieve a sustained reduction in the number of radiographic examinations of the cervical spine, lumbar spine and knees performed for GPs

    International Nuclear Information System (INIS)

    Glaves, J.

    2005-01-01

    AIM: To determine if the use of request guidelines can achieve a sustained reduction in the number of radiographic examinations of the cervical spine, lumbar spine and knee joints performed for general practitioners (GPs). METHODS: GPs referring to three community hospitals and a district general hospital were circulated with referral guidelines for radiography of the cervical spine, lumbar spine and knee, and all requests for these three examinations were checked. Requests that did not fit the guidelines were returned to the GP with an explanatory letter and a further copy of the guidelines. Where applicable, a large-joint replacement algorithm was also enclosed. If the GP maintained the opinion that the examination was indicated, she or he had the option of supplying further justifying information in writing or speaking to a consultant radiologist. RESULTS: Overall the number of radiographic examinations fell by 68% in the first year, achieving a 79% reduction in the second year. For knees, lumbar spine and cervical spine radiographs the total reductions were 77%, 78% and 86%, respectively. CONCLUSION: The use of referral guidelines, reinforced by request checking and clinical management algorithms, can produce a dramatic and sustained reduction in the number of radiographs of the cervical spine, lumbar spine and knees performed for GPs

  12. Value of radiographic examination of the knee joint for the orthopedic surgeon; Wertigkeit der radiologischen Bildgebung beim Kniegelenk fuer den Orthopaeden

    Energy Technology Data Exchange (ETDEWEB)

    Pietsch, M.; Hofmann, S. [Allgemeines und Orthopaedisches LKH Stolzalpe (Austria). Abteilung fuer Orthopaedie und orthopaedische Chirurgie

    2006-01-01

    Extended radiographic examinations offer excellent options for diagnosis and strategy for treatment of the knee joint. The whole-leg radiograph is indispensable in measuring alignment for osteotomy or total knee arthroplasty (TKA). Fluoroscopically assisted varus-valgus stress radiographs provide the possibility for verifying mechanical function of the implanted knee prosthesis. Ultrasound examinations have been widely replaced by magnetic resonance imaging (MRI). MRI is the golden standard to examine intra-articular structures of the knee (meniscus, ligaments, cartilage) and surrounding soft tissue. For evaluating femoral and tibial torsion and determining axial rotation of TKA, computed tomography (CT) is best qualified. Imaging of the patellofemoral joint (patella instability) is difficult; CT scans in combination with true lateral radiographs seem to be helpful. (orig.) [German] Die erweiterte Roentgendiagnostik bietet gute Moeglichkeiten der Diagnose und Therapieplanung beim Kniegelenk. Das Ganzbeinroentgen ist unabdingbar zur Achsvermessung bei der Planung einer Umstellungsosteotomie oder der Implantation einer Knietotalendoprothese (KTEP). Varus-/Valgusaufnahmen unter Bildwandler gestatten die Ueberpruefung der Mechanik einer liegenden KTEP. Sonographische Untersuchungen des Kniegelenks sind weitgehend durch die Magnetresonanztomographie (MRT) ersetzt. Die MRT ist die Methode der Wahl zur Beurteilung der Kniebinnenstrukturen (Meniskus, Baender, Knorpel) und der umgebenden Weichteile. Zur Bestimmung der Torsion von Femur und Tibia sowie der Rotation der Komponenten einer KTEP ist die Computertomographie (CT) am besten geeignet. Die Beurteilung des Femorpatellargelenks (Patellainstabilitaet) ist schwierig, am vielversprechendsten erscheint die CT in Kombination mit streng seitlichen Roentgenbildern. (orig.)

  13. Observer agreement in the reporting of knee and lumbar spine magnetic resonance (MR) imaging examinations: Selectively trained MR radiographers and consultant radiologists compared with an index radiologist

    Energy Technology Data Exchange (ETDEWEB)

    Brealey, S., E-mail: stephen.brealey@york.ac.uk [Department of Health Sciences, University of York, York YO10 5DD (United Kingdom); Piper, K., E-mail: keith.piper@canterbury.ac.uk [Department of Allied Health Professions, Canterbury Christ Church University, Canterbury, Kent CT1 1QU (United Kingdom); King, D., E-mail: david.g.king@york.nhs.uk [York Hospital, Wigginton Road, York YO31 8HE (United Kingdom); Bland, M., E-mail: martin.bland@york.ac.uk [Department of Health Sciences, University of York, York YO10 5DD (United Kingdom); Caddick, J., E-mail: Julie.Caddick@york.nhs.uk [York Hospital, Wigginton Road, York YO31 8HE (United Kingdom); Campbell, P., E-mail: peter.campbell@york.nhs.uk [York Hospital, Wigginton Road, York YO31 8HE (United Kingdom); Gibbon, A., E-mail: anthony.j.gibbon@york.nhs.uk [York Hospital, Wigginton Road, York YO31 8HE (United Kingdom); Highland, A., E-mail: Adrian.Highland@sth.nhs.uk [Sheffield Teaching Hospitals, Herries Road, Sheffield S5 7AU (United Kingdom); Jenkins, N., E-mail: neil.jenkins@york.nhs.uk [York Hospital, Wigginton Road, York YO31 8HE (United Kingdom); Petty, D., E-mail: daniel.petty@york.nhs.uk [York Hospital, Wigginton Road, York YO31 8HE (United Kingdom); Warren, D., E-mail: david.warren@york.nhs.uk [York Hospital, Wigginton Road, York YO31 8HE (United Kingdom)

    2013-10-01

    Purpose: To assess agreement between trained radiographers and consultant radiologists compared with an index radiologist when reporting on magnetic resonance imaging (MRI) examinations of the knee and lumbar spine and to examine the subsequent effect of discordant reports on patient management and outcome. Methods: At York Hospital two MR radiographers, two consultant radiologists and an index radiologist reported on a prospective, random sample of 326 MRI examinations. The radiographers reported in clinical practice conditions and the radiologists during clinical practice. An independent consultant radiologist compared these reports with the index radiologist report for agreement. Orthopaedic surgeons then assessed whether the discordance between reports was clinically important. Results: Overall observer agreement with the index radiologist was comparable between observers and ranged from 54% to 58%; for the knee it was 46–57% and for the lumbar spine was 56–66%. There was a very small observed difference of 0.6% (95% CI −11.9 to 13.0) in mean agreement between the radiographers and radiologists (P = 0.860). For the knee, lumbar spine and overall, radiographers’ discordant reports, when compared with the index radiologist, were less likely to have a clinically important effect on patient outcome than the radiologists’ discordant reports. Less than 10% of observer's reports were sufficiently discordant with the index radiologist's reports to be clinically important. Conclusion: Carefully selected MR radiographers with postgraduate education and training reported in clinical practice conditions on specific MRI examinations of the knee and lumbar spine to a level of agreement comparable with non-musculoskeletal consultant radiologists.

  14. Observer agreement in the reporting of knee and lumbar spine magnetic resonance (MR) imaging examinations: Selectively trained MR radiographers and consultant radiologists compared with an index radiologist

    International Nuclear Information System (INIS)

    Brealey, S.; Piper, K.; King, D.; Bland, M.; Caddick, J.; Campbell, P.; Gibbon, A.; Highland, A.; Jenkins, N.; Petty, D.; Warren, D.

    2013-01-01

    Purpose: To assess agreement between trained radiographers and consultant radiologists compared with an index radiologist when reporting on magnetic resonance imaging (MRI) examinations of the knee and lumbar spine and to examine the subsequent effect of discordant reports on patient management and outcome. Methods: At York Hospital two MR radiographers, two consultant radiologists and an index radiologist reported on a prospective, random sample of 326 MRI examinations. The radiographers reported in clinical practice conditions and the radiologists during clinical practice. An independent consultant radiologist compared these reports with the index radiologist report for agreement. Orthopaedic surgeons then assessed whether the discordance between reports was clinically important. Results: Overall observer agreement with the index radiologist was comparable between observers and ranged from 54% to 58%; for the knee it was 46–57% and for the lumbar spine was 56–66%. There was a very small observed difference of 0.6% (95% CI −11.9 to 13.0) in mean agreement between the radiographers and radiologists (P = 0.860). For the knee, lumbar spine and overall, radiographers’ discordant reports, when compared with the index radiologist, were less likely to have a clinically important effect on patient outcome than the radiologists’ discordant reports. Less than 10% of observer's reports were sufficiently discordant with the index radiologist's reports to be clinically important. Conclusion: Carefully selected MR radiographers with postgraduate education and training reported in clinical practice conditions on specific MRI examinations of the knee and lumbar spine to a level of agreement comparable with non-musculoskeletal consultant radiologists

  15. Associations between physical examination, laboratory, and radiographic findings and outcome and subsequent racing performance of foals with Rhodococcus equi infection: 115 cases (1984-1992)

    International Nuclear Information System (INIS)

    Ainsworth, D.M.; Eicker, S.W.; Yeager, A.E.; Sweeney, C.R.; Viel, L.; Tesarowski, D.; Lavoie, J.P.; Hoffman, A.; Paradis, M.R.; Reed, S.M.

    1998-01-01

    Objective-To determine whether physical examination, laboratory, or radiographic abnormalities in foals with Rhodococcus equi infection were associated with survival, ability to race at least once after recovery, or, for foals that survived and went on to race, subsequent Facing performance. Design-Retrospective study. Animals-49 Thoroughbreds and 66 Standardbreds admitted to 1 of 6 veterinary teaching hospitals between 1984 and 1992 in which R equi infection was positively diagnosed. Procedure-Results of physical examination, laboratory testing, and thoracic radiography were reviewed. Indices of Facing performance were obtained for feats that recovered and eventually raced and compared with values for the US racing population. Results-83 (72%) feats survived. Foals that did not survive were more likely to have extreme tachycardia (heart rate > 100 beats/min), be in respiratory distress, and have severe radiographic abnormalities on thoracic radiographs at the time of initial examination than were foals that survived. Clinicopathologic abnormalities were not associated with whether feats did or did not survive. Forty-five of the 83 surviving foals (54%) eventually raced at least once, but none of the factors examined was associated with whether foals went on to race. Racing performance of foals that raced as adults was not significantly different from that of the US racing population. Clinical Implications-R equi infection in foals is associated with a decreased chance of racing as an adult, however, foals that eventually go on to race perform comparably to the US racing population

  16. Survey of image quality and patient dose in simple radiographic examinations: establishing guidance levels and comparison with international standards

    International Nuclear Information System (INIS)

    Manatrakul, N.; Bunsoong, T.; Krisanachinda, A.; Suwanpradit, P.; Rungruengthanakit, P.; Kanchart, S.; Chaiwong, Rajikorn; Tsapakig, V.A.

    2008-01-01

    Purpose: To investigate image quality and patient dose for commonly radiographic examinations in Thailand, to establish national reference or guidance levels (GL) and compare with international standards, as part of an International Atomic Energy Agency (IAEA) project on Radiation Protection of Patients and Medical Exposure Control (RAS/9/034 and RAS/9/047). Materials and Methods: Film reject rate analysis, image quality and patient dose assessment before and after Quality Control (QC) implementation were investigated in 8 X-ray machines in 4 hospitals. Air kerma (in mGy) at 1 meter focus-detector-distance for different kVp settings for each X-ray machines were measured using an ionization chamber under standardized condition. The entrance skin air kerma (ESAK) for Chest PA, Lumbar spine AP, Lumbar spine LAT, Pelvis AP, Abdomen AP, Skull AP and Skull LAT were calculated for at least 10 adult patients of average body mass (60 to 80 kg) for each projection. The obtained values were compared with international standards. Results: The highest film rejection rate reduction recorded after corrective actions from 9.15% to 6.8%. Mean ESAK values were less than international standards both before and after QC implementation in all projections but Chest PA projection. Maximum ESAK in Chest PA projection before corrective action was 0.55 mGy which was higher than the IAEA GL of 0.2 mGy. However, it was reduced to 0.25 mGy after QC tests on X- ray machine and using high kilovoltage (kV) technique. Conclusion: Proposed national GL of Thailand were obtained by estimating the 3rd quartile of the whole sample: Chest PA: 0.1 mGy, Lumbar Spine AP: 2.1 mGy, Lumbar Spine LAT: 6.3 mGy, Pelvis AP: 1.8 mGy, Abdomen: 1.5 mGy, Skull PA: 1.3 mGy and Skull LAT: 0.9 mGy. (author)

  17. Method for the radiographic examination of the walls or components of an essentially closed vessel, and also the provision of means for the application of the method

    International Nuclear Information System (INIS)

    1978-01-01

    Method for the radiographic examination of the wall ports or supporting components of an essentially closed vessel, whereby one brings to the side of the vessel walls or supports under examination a radiation source and, to the opposite side, a radiation sensitive film, the film being irradiated by the source and thereafter developed, characterised in that one introduces into the inside of the vessel a hollow tube at a unique distance from the wall or support component, at least one end of the hollow tube being fed out and in which the hollow tube, during the period of the examination, the irradiation source or an irradiation sensitive film is introduced. (G.C.)

  18. Advances in percutaneous stone surgery

    OpenAIRE

    Hartman, Christopher; Gupta, Nikhil; Leavitt, David; Hoenig, David; Okeke, Zeph; Smith, Arthur

    2015-01-01

    Treatment of large renal stones has changed considerably in recent years. The increasing prevalence of nephrolithiasis has mandated that urologists perform more surgeries for large renal calculi than before, and this has been met with improvements in percutaneous stone surgery. In this review paper, we examine recent developments in percutaneous stone surgery, including advances in diagnosis and preoperative planning, renal access, patient position, tract dilation, nephroscopes, lithotripsy, ...

  19. Advances in percutaneous stone surgery.

    Science.gov (United States)

    Hartman, Christopher; Gupta, Nikhil; Leavitt, David; Hoenig, David; Okeke, Zeph; Smith, Arthur

    2015-01-01

    Treatment of large renal stones has changed considerably in recent years. The increasing prevalence of nephrolithiasis has mandated that urologists perform more surgeries for large renal calculi than before, and this has been met with improvements in percutaneous stone surgery. In this review paper, we examine recent developments in percutaneous stone surgery, including advances in diagnosis and preoperative planning, renal access, patient position, tract dilation, nephroscopes, lithotripsy, exit strategies, and post-operative antibiotic prophylaxis.

  20. Dose levels from thoracic and pelvic examinations in two pediatric radiological departments in Norway - a comparison study of dose-area product and radiographic technique

    International Nuclear Information System (INIS)

    Kjernlie Saether, Hilde; Traegde Martinsen, Anne Catrine; Lagesen, Bente; Platou Holsen, Eva; Oevreboe, Kirsti Marie

    2010-01-01

    Background: Pediatric doses expressed in dose-area product (DAP) can be retrieved from only a few publications; most of which correlate DAP to patient size or large age spans. In clinical practice age is often the only available parameter describing the patient, and thus, evaluation of dose levels in pediatric radiology on the basis of DAP related to age alone would be useful in optimization work. Purpose: To provide comparable data on age-related DAP from thoracic and pelvic radiological examinations of children, and evaluate the usefulness of comparing age-related DAP and radiographic technique between systems to identify areas with potential for optimization. Material and Methods: DAP, age, and radiographic technique were registered for 575 thoracic examinations and 371 pelvic examinations of children from newborn up to 14 years of age in groups with an age span of 1 year, performed with two digital flat-panel systems and one computed radiography system. Results: DAP varies from 2.2 to 54.0 mGycm2 for thoracic examinations, and from 4.6 to 532.5 mGycm2 for pelvic examinations. There are significant differences in DAP between systems and departments due to differences in technique, equipment, and staff. Conclusion: This study provides comparable data on age-related DAP from thoracic and pelvic radiological examinations of children, which could be used as an input to estimate diagnostic reference levels. The comparison between systems of DAP and radiographic technique has proven useful in identifying areas where there may be a potential for optimization.

  1. Development of a technique for contrast radiographic examination of the gastrointestinal tract in ball pythons (Python regius).

    Science.gov (United States)

    Banzato, Tommaso; Russo, Elisa; Finotti, Luca; Zotti, Alessandro

    2012-07-01

    To develop a technique for radiographic evaluation of the gastrointestinal tract in ball pythons (Python regius). 10 ball python cadavers (5 males and 5 females) and 18 healthy adult ball pythons (10 males and 8 females). Live snakes were allocated to 3 groups (A, B, and C). A dose (25 mL/kg) of barium sulfate suspension at 3 concentrations (25%, 35%, and 45% [wt/vol]) was administered through an esophageal probe to snakes in groups A, B, and C, respectively. Each evaluation ended when all the contrast medium had reached the large intestine. Transit times through the esophagus, stomach, and small intestine were recorded. Imaging quality was evaluated by 3 investigators who assigned a grading score on the basis of predetermined criteria. Statistical analysis was conducted to evaluate differences in quality among the study groups. The esophagus and stomach had a consistent distribution pattern of contrast medium, whereas 3 distribution patterns of contrast medium were identified in the small intestine, regardless of barium concentration. Significant differences in imaging quality were detected among the 3 groups. Radiographic procedures were tolerated well by all snakes. The 35% concentration of contrast medium yielded the best imaging quality. Use of contrast medium for evaluation of the cranial portion of the gastrointestinal tract could be a reliable technique for the diagnosis of gastrointestinal diseases in ball pythons. However, results of this study may not translate to other snake species because of variables identified in this group of snakes.

  2. Radiographic evaluations

    International Nuclear Information System (INIS)

    Williams, J.L.

    1988-01-01

    The author describes how to: perform a systematic evaluation of a chest radiograph; state the classic radiographic description of hyaline membrane disease; list the conditions that cause hyperaeration and describe the radiologic feature of hyperaeration; describe the radiograph of a patient with a congenital diaphragmatic hernia; identify optimum placement of an endotracheal tube, gastric feeding tube, and umbilical artery catheter on a radiograph; differentiate between pulmonary interstitial air and hyaline membrane disease; select radiographic features that would indicate the presence of a tension pneumothorax; describe a lateral decubitus projection and state the type of problem it is most often used to identify; explain the procedure used in obtaining a lateral neck radiograph and list two problems that may require this view; and describe the radiograph of a patient with cystic fibrosis

  3. Digitization of conventional radiographs

    International Nuclear Information System (INIS)

    Wenz, W.; Buitrago-Tellez, C.; Blum, U.; Hauenstein, K.H.; Gufler, H.; Meyer, E.; Ruediger, K.

    1992-01-01

    The diagnostic value of a digitization system for analogue films based on a charge-coupled-device (CCD) scanner with adjustable resolution of 2.5 or 5 lp/mm was assessed. Some 110 skeletal radiographs, 50 contrast studies, including 25 of patients with Crohn's disease, and 70 abdominal plain films before and after successful lithotripsy for renal stones were digitized. Receiver operating characteristic (ROC) studies showed improved detection of cortical and trabecular defects with contrast-optimized digitized films. Edge enhancement algorithms yielded no additional information. Inflammatory lesions of Crohn's disease were detected equally well by conventional films and digitized images. A statistically significant improvement (p [de

  4. Evaluation of underexposed conventional radiographs after digitization. Auswertung fehlbelichteter konventioneller Roentgenaufnahmen nach Digitalisierung

    Energy Technology Data Exchange (ETDEWEB)

    Wenz, W. (Freiburg Univ. (Germany). Abt. Roentgendiagnostik); Buitrago-Tellez, C. (Freiburg Univ. (Germany). Abt. Roentgendiagnostik); Moenig, H. (Freiburg Univ. (Germany). Inst. fuer Biophysik und Strahlenbiologie); Niemeier, R. (Digital Diagnostik Deutschland GmbH, Freiburg im Breisgau (Germany))

    1993-02-01

    Inadequate exposure of analogue radiographs is reported in the literature to occur in 5-25% of cases. Therefore, the present study was performed to test whether selective image processing after digitization could reveal diagnostic details on underexposed radiographs. In addition, the minimal exposure values required for diagnostic purposes after adequate image processing were studied. Phantom studies, organ preparations and measurements of physical parameters with decreasing exposure values were performed. The detection of anatomic and pathologic (nondisplaced fracture lines, microcalcification and renal stones) structures were evaluated by 12 readers. Radiographs with exposure values 20-40% lower than 'ideal' values can provide adequate diagnostic images after digital processing. The diagnostic information is significantly impaired with values under 50% of the correct exposure values. In conclusion, this method is adequate to save underexposed radiographs for diagnostic purposes and to avoid repeated examinations. (orig.)

  5. Pocket atlas of radiographic anatomy

    International Nuclear Information System (INIS)

    Moeller, T.B.; Reif, E.; Stark, P.

    1993-01-01

    The 'Pocket Atlas of Radiographic Anatomy' presents 170 radiographs of the various body regions of adults, showing only the normal radiographic anatomy. Each radiograph is supplemented on the opposite page by a drawing of the particular body region. There is no commenting text, but the drawings are provided with captions in English. The atlas is a useful guide for interpreting radiographs. The pictures are arranged in chapters entitled as follows: Skeletal Imaging (skull, spine, upper extremity), lower extremity; Miscellaneous Plain Films (chest, mammogram, trachea, lung tomograms); Contrast Examinations (gastrointestinal tract, intravenous contrast examinations, arthrography, angiography); Special Examinations (myelograms, lymphangiograms, bronchograms, sialograms). (UWA). 348 figs [de

  6. Kidney Stones (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Kidney Stones KidsHealth / For Parents / Kidney Stones What's in ... other treatments to help remove the stones. How Kidney Stones Form It's the kidneys' job to remove ...

  7. An in-vitro comparison of the radiographic and actual gutta-percha terminus.

    Science.gov (United States)

    Namazikhah, M S; Ghiai, M; Parkin, M J; Puccinelli, L

    2000-06-01

    The purpose of this study was to investigate the difference between the radiographic gutta-percha terminus and the actual gutta-percha terminus of human molars by comparing radiographic obturation results with actual obturation results. Forty maxillary palatal roots and 50 mandibular distal roots were randomly selected from a population of 540. They were then mounted in stone and radiographed. Conventional endodontic therapy was completed using stainless-steel K files and lateral condensation. Each radiographic gutta-percha terminus was evaluated under 4.5x magnification by three examiners following the completion of root canal therapy. These results were recorded. Each tooth was then removed from its mounting, and the actual gutta-percha terminus was evaluated under 4.5x magnification. These results were recorded and compared to the radiographic gutta-percha terminus results. In all 90 teeth examined, the actual gutta-percha terminus was equal to or longer than the radiographic gutta-percha terminus. In the 50 mandibular distal roots, the actual gutta-percha terminus averaged 0.645 mm longer than the radiographic gutta-percha terminus. In the 40 maxillary palatal roots, this difference measured 0.6375 mm.

  8. Stone coalgebras

    NARCIS (Netherlands)

    C.A. Kupke (Clemens); A. Kurz (Alexander); Y. Venema

    2003-01-01

    textabstractIn this paper we argue that the category of Stone spaces forms an interesting base category for coalgebras, in particular, if one considers the Vietoris functor as an analogue to the power set functor on the category of sets. We prove that the so-called descriptive general frames, which

  9. The Value of History, Physical Examination, and Radiographic Findings in the Diagnosis of Symptomatic Meniscal Tear among Middle-Age Subjects with Knee Pain

    Science.gov (United States)

    Katz, Jeffrey N.; Smith, Savannah R.; Yang, Heidi Y.; Martin, Scott D.; Wright, John; Donnell-Fink, Laurel A.; Losina, Elena

    2016-01-01

    Objective To evaluate the utility of clinical history, radiographic and physical exam findings in the diagnosis of symptomatic meniscal tear (SMT) in patients over age 45, in whom concomitant osteoarthritis is prevalent. Methods In a cross-sectional study of patients from two orthopedic surgeons’ clinics we assessed clinical history, physical examination and radiographic findings in patients over 45 with knee pain. The orthopedic surgeons rated their confidence that subjects’ symptoms were due to MT; we defined the diagnosis of SMT as at least 70% confidence. We used logistic regression to identify factors independently associated with diagnosis of SMT and we used the regression results to construct an index of the likelihood of SMT. Results In 174 participants, six findings were associated independently with the expert clinician having ≥70% confidence that symptoms were due to MT: localized pain, ability to fully bend the knee, pain duration <1 year, lack of varus alignment, lack of pes planus, and absence of joint space narrowing on radiographs. The index identified a low risk group with 3% likelihood of SMT. Conclusion While clinicians traditionally rely upon mechanical symptoms in this diagnostic setting, our findings did not support the conclusion that mechanical symptoms were associated with the expert’s confidence that symptoms were due to MT. An index that includes history of localized pain, full flexion, duration <1 year, pes planus, varus alignment, and joint space narrowing can be used to stratify patients according to their risk of SMT and it identifies a subgroup with very low risk. PMID:27390312

  10. Radiographic testing

    International Nuclear Information System (INIS)

    Kuster, J.

    1978-01-01

    In view of great differencies in X-ray transmission it is more difficult to get optimum radiographs of plastics and especially of reinforced plastics than for example of metals. A procedure will be reported how to get with little effort optimum radiographs especially also in the range of long wave-length radiation corresponding 10 to 25 kV.P. (orig.) [de

  11. Radiographic examination of keel bone damage in living laying hens of different strains kept in two housing systems.

    Directory of Open Access Journals (Sweden)

    Beryl Katharina Eusemann

    Full Text Available A high prevalence of deviations and fractures of the keel bone is a widespread welfare problem in laying hens. The aim of this study was to experimentally investigate this multifactorial problem throughout the laying period and to compare the prevalence and severity in different layer lines and different housing systems. High performing white (WLA and brown (BLA pure bred layer lines and low performing white (R11, G11 and brown layer lines (L68 were kept in both single cages and a floor housing system. A total of 97 hens (19 or 20 from each line, respectively were repeatedly radiographed in the 35th, 51st and 72nd week of age. Fracture prevalence increased with age (p<0.001. The proportion of deviated keel bone area increased only for caged BLA, WLA and R11 hens (p<0.05 and was significantly higher for caged WLA and R11 hens compared to floor-housed WLA and R11 hens in the 72nd week of age (p<0.05. In the 72nd week of age hens in the floor housing system showed significantly more fractures than hens kept in cages (p<0.05. Prevalence of keel bone deviations was significantly higher in the white layer line R11 but significantly lower in the white layer line G11 compared to both brown layer lines and WLA (p<0.05. Brown layers showed significantly more fractures than white layers (p<0.05 in the 51st and 72nd week of age. Within the brown layers there was a significantly lower prevalence of deviations (p<0.05 and fractures (p<0.05 in the low performing (L68 compared to the high performing line (BLA. Our results show a different development of keel bone damage in caged compared to floor-housed hens under experimental conditions. Additionally, they indicate genetic effects on keel bone damage.

  12. Radiographic tales

    DEFF Research Database (Denmark)

    Mussmann, Bo Redder

    Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities. Meth...... of their narrative alertness. Errors and failure to keep the time schedule can, however, lead the radiographers to a change of perspective that makes them displace man from the scene of radiography by playing on the premises of technology.......Purpose Until now a large number of scientific studies have focused on technological aspects of radiography. This study is a step in another direction which examines the relationship between man and technology within radiography instead of considering man and technology as separate entities...... a practice in which the relationship between man and technology is marked by a struggle of domination of one over the other. The struggle expresses itself through two competing plots: A diagnostic plot with a prevailing, but not merely chronological structure mostly composed of events tied to pathology...

  13. Screening for congenital dislocation of the hip in the newborn: The role of clinical, ultrasonographic and radiographic examination

    International Nuclear Information System (INIS)

    Dunn, P.M.

    1987-01-01

    The concept of examining all young infants for congenital dislocation of the hip (CDH) dates back to Le Damany in 1914, though it was Ortolani who stimulated widespread clinical screening with the publication of his method of examination in 1948. His technique was improved by Barlow and others and is now often referred to as the Ortolani/Barlow manoeuvre. Meanwhile, following the method of Hilgenreiner, Putti advocated in 1933 radiological screening of all newborn hips. In 1958 Andren and Von Rosen described their new radiological technique in which hip subluxation was provoked prior to x-ray. Although radiological examination has been criticised as a screening method, it is still apparently widely used in Europe, especially in German-speaking countries. More recently dynamic sonographic examination of the hips has been used for neonatal screening

  14. Gypsum accumulation on carbonate stone

    Science.gov (United States)

    McGee, E.S.; Mossotti, V.G.

    1992-01-01

    The accumulation of gypsum on carbonate stone has been investigated through exposure of fresh samples of limestone and marble at monitored sites, through examination of alteration crusts from old buildings and through laboratory experiments. Several factors contribute to gypsum accumulation on carbonate stone. Marble or limestone that is sheltered from direct washing by rain in an urban environment with elevated pollution levels is likely to accumulate a gypsum crust. Crust development may be enhanced if the stone is porous or has an irregular surface area. Gypsum crusts are a surficial alteration feature; gypsum crystals form at the pore opening-air interface, where evaporation is greatest.

  15. Bone marrow evaluation in small cell carcinoma of the lung. [Radiographic and nuclear medical examinations also performed

    Energy Technology Data Exchange (ETDEWEB)

    Giaccone, G.; Ciuffreda, L.; Donadio, M.; Ferrati, P.; Risio, M.; Leria, G.; Bonardi, G.; Calciati, A.

    1987-01-01

    Bone marrow examination is commonly included in the staging of small cell lung carcinoma (SCLC). We reviewed marrow samples of 103 patients. Marrow examination was mainly performed by unilateral or bilateral biopsy of iliac crests, using a Jamshidi needle. Only 6 of 97 evaluable cases (6.2%) were positive for marrow metastases at staging, and in 3 cases (3%) bone marrow was the only metastatic site. No focal metastases were found in additional sections made from the blocks of negative samples. In our experience bone marrow biopsy was of little value in staging SCLC. Bilateral biopsy plus aspirate, with the addition of more sophisticated staining techniques might, however, provide a higher yield of positive marrow involvement.

  16. Papillary Ductal Plugging is a Mechanism for Early Stone Retention in Brushite Stone Disease

    DEFF Research Database (Denmark)

    Williams, James C; Borofsky, Michael S; Bledsoe, Sharon B

    2018-01-01

    PURPOSE: Mechanisms of early stone retention in the kidney are under studied and poorly understood. To date attachment via Randall's plaque is the only widely accepted theory in this regard, which is best described in idiopathic calcium oxalate stone formers. Brushite stone formers are known...... to have distinct papillary morphology relative to calcium oxalate stone formers. As such we sought to determine whether stone attachment mechanisms in such patients may be similarly unique. MATERIALS AND METHODS: Patients undergoing percutaneous and or ureteroscopic procedures for stone removal consented...... to endoscopic renal papillary examination and individual stone collection. Each removed stone was processed using micro computerized tomography to assess the 3-dimensional microstructure and the minerals contained, and search for common structural features indicative of novel mechanisms of early growth...

  17. Animal radiographs

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter presents historical x rays of a wide variety of animals taken within 5 years of the discovery of x radiation. Such photos were used as tests or as illustrations for radiographic publications. Numerous historical photographs are included. 10 refs

  18. Acute management of stones

    DEFF Research Database (Denmark)

    Jung, Helene; Osther, Palle J S

    2015-01-01

    INTRODUCTION: Stone management is often conservative due to a high spontaneous stone passage rate or non-symptomatic calyceal stones that do not necessarily require active treatment. However, stone disease may cause symptoms and complications requiring urgent intervention. MATERIAL AND METHODS: I...... with careful consideration of stone size and location, symptoms, patient comorbidity and radiation dose. CONCLUSION: In case of infective hydronephrosis, compromised renal function or persistent pain despite adequate analgesic treatment acute intervention is indicated....

  19. Infection (urease) stones.

    Science.gov (United States)

    Griffith, D P; Osborne, C A

    1987-01-01

    Infection-induced stones in man probably form solely as a consequence of urealysis which is catalyzed by the bacterial protein urease. Urease stones composed of struvite and carbonate-apatite may form primarily, or as secondary stones or pre-existent metabolic stones. Struvite stones form and grow rapidly owing to (a) supersaturation of urine with stone forming salts, (b) 'salting out' of poorly soluble organic substances normally dissolved in urine and (c) ammonia-induced destruction of the normally protective urothelial glycosaminoglycan layer. Immature (predominantly organic) matrix stones mature into densely mineralized stones. Curative treatment is possible only by eliminating all of the stone and by eradicating all urinary and parenchymal infection. A variety of operative and pharmaceutical approaches are available. Patient treatment must be individualized inasmuch as some patients are better candidates for one type of treatment than another.

  20. Can sonography define the chemical composition of gall stones

    International Nuclear Information System (INIS)

    Frentzel-Beyme, B.; Faehndrich, R.; Arnan-Thiele, B.

    1983-01-01

    Eight sonographic patterns caused by gall stones are described. In an attempt to explain these different appearances, 62 stones were analysed chemically and physically. The chemical composition of the stones did not correlate with their sonographic pattern. Cholesterol stones cannot be recognised as such by sonography. The formation of an acoustic shadow depends largely on the position of the stone within the acoustic beam. It therefore follows that the examination must be done by keeping the focal plane of the transducer in proper relationship to the stone. (orig.) [de

  1. Assessment of stone composition in the management of urinary stones

    NARCIS (Netherlands)

    Kijvikai, Kittinut; de la Rosette, J. J. M.

    2011-01-01

    Several explanations have been suggested to account for the failure of extracorporeal shockwave lithotripsy (ESWL) treatment in patients with urinary stones, including large stone volume, unfavorable stone location or composition and the type of lithotriptor used. Unfavorable stone composition is

  2. Radiographic element

    International Nuclear Information System (INIS)

    Abbott, T.I.; Jones, C.G.

    1984-01-01

    Radiographic elements are disclosed comprised of first and second silver halide emulsion layers separated by an interposed support capable of transmitting radiation to which the second image portion is responsive. At least the first imaging portion contains a silver halide emulsion in which thin tubular silver halide grains of intermediate aspect ratios (from 5:1 to 8:1) are present. Spectral sensitizing dye is adsorbed to the surface of the tubular grains. Increased photographic speeds can be realized at comparable levels of crossover. (author)

  3. Multiple Pulp Stones in Primary and Developing Permanent Dentition: A Report of 4 Cases

    Directory of Open Access Journals (Sweden)

    Mohita Marwaha

    2012-01-01

    Full Text Available Pulp stones are foci of calcification or discrete calcifications in the dental pulp. They are frequently found on bitewing and periapical radiographs, but their occurrence in entire dentition is unusual. We are reporting four cases in which the occurrence of pulp stones ranged from their presence in just primary teeth (Cases 1 and 2 to involvement of young permanent teeth also (Case 3 and even unerupted permanent teeth (Case 4. In all the cases, dental, medical, and family histories as well as the findings from the clinical examination of the patient were not contributory. Histopathological report revealed true denticle. Metabolic evaluation of patients through liver function test, kidney function test, and blood investigation did not show any metabolic disorders. Patients were also evaluated for any systemic, syndromic, or genetic involvement, but this was also noncontributing. Therefore, it is suggested that these unusual cases may be of idiopathic origin.

  4. Bone marrow edema pattern in advanced hip osteoarthritis: quantitative assessment with magnetic resonance imaging and correlation with clinical examination, radiographic findings, and histopathology

    International Nuclear Information System (INIS)

    Taljanovic, Mihra S.; Schwartz, Stephanie A.; Graham, Anna R.; Benjamin, James B.; Gmitro, Arthur F.; Krupinski, Elizabeth A.; Hunter, Tim B.; Resnick, Donald L.

    2008-01-01

    To correlate the amount of bone marrow edema (BME) calculated by magnetic resonance imaging(MRI) with clinical findings, histopathology, and radiographic findings, in patients with advanced hip osteoarthritis(OA). The study was approved by The Institutional Human Subject Protection Committee. Coronal MRI of hips was acquired in 19 patients who underwent hip replacement. A spin echo (SE) sequence with four echoes and separate fast spin echo (FSE) proton density (PD)-weighted SE sequences of fat (F) and water (W) were acquired with water and fat suppression, respectively. T2 and water:fat ratio calculations were made for the outlined regions of interest. The calculated MRI values were correlated with the clinical, radiographic, and histopathologic findings. Analyses of variance were done on the MRI data for W/(W + F) and for T2 values (total and focal values) for the symptomatic and contralateral hips. The values were significantly higher in the study group. Statistically significant correlations were found between pain and total W/(W + F), pain and focal T2 values, and the number of microfractures and calculated BME for the focal W/(W + F) in the proximal femora. Statistically significant correlations were found between the radiographic findings and MRI values for total W/(W + F), focal W/(W + F) and focal T2 and among the radiographic findings, pain, and hip movement. On histopathology, only a small amount of BME was seen in eight proximal femora. The amount of BME in the OA hip, as measured by MRI, correlates with the severity of pain, radiographic findings, and number of microfractures. (orig.)

  5. Radiographic apparatus

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1979-01-01

    Raytheon Company, U.S.A. have patented an on-line electronic system of normalising the responses from the photomultiplier tubes used in conjunction with a scintillator in an X-ray radiographic camera. A problem with present cameras is that the individual photomultipliers have different intensity responses which also change in time with respect to each other. The individual responses of each photomultiplier tube are measured with a uniform sheet of radioactive material in front of the camera. The associated electronic equipment then calculates scaling factors which give all photomultiplier tubes an identical response and then places these factors in an addressable store. The store is then addressed in an on-line mode to produce a visual display of the transmitted X-rays. (U.K.)

  6. Radiographic apparatus

    International Nuclear Information System (INIS)

    Dalton, B.L.

    1984-01-01

    This patent application describes a radiographic apparatus including an array of radiation sensors, a source of radiation for projecting a beam through a body and means for moving one of said source and array relative to the body and for producing an electrical signal representative of the movement of the other of said source and array needed to bring the array into register with the beam. Drive means are arranged to move the other of said source and array in response to the electrical signal. In one embodiment, the source is rotated by an amount measured by a grating and associated electronics. The required movement of the array to maintain registration is calculated and transmitted to a driver. Alternatively, a laser may be mounted with the same and the array driven so that the laser beam continuously impinges on a photocell mounted with the array. (author)

  7. Validity of plain film radiograph (KUB) in the diagnosis of urolithiasis

    International Nuclear Information System (INIS)

    Maravilla, L.M.; Castillo, E.C.

    1994-01-01

    The article is about the study on the validity of plain film radiograph (KUB) in the diagnosis of urolithiasis in Filipino patients. This is based on the fact that 75% to 85% of stones are composed of calcium phosphate. Radiolucent, uric acid, urate, xanthine and matrix stones which comprised 5% to 8% cases may also contain radiographically detectable amounts of calcium oxalates. The study will also determine the sensitivity, specificity, positive and negative predictive value of KUB. 10 refs.; 3 tabs

  8. Radiographers and trainee radiologists reporting accident radiographs

    DEFF Research Database (Denmark)

    Buskov, L; Abild, A; Christensen, A

    2013-01-01

    To compare the diagnostic accuracy and clinical validity of reporting radiographers with that of trainee radiologists whom they have recently joined in reporting emergency room radiographs at Bispebjerg University Hospital....

  9. Evolution of stone management in Australia.

    Science.gov (United States)

    Lee, Ming-Chak; Bariol, Simon Virgil

    2011-11-01

    What's known on the subject? and What does the study add? There is very little contemporary data regarding stone management in Australia. This study assesses the impact of technological advances on stone management practises, and raises questions as to why there is an increasing rate of intervention for stone disease in Australia. Knowledge of management trends as demonstrated in this paper give individual surgeons a guideline for contemporary practise in this country. • To examine trends in the operative management of upper urinary tract stone disease in Australia over the past 15 years. • The Medicare Australia and Australian Institute of Health and Welfare databases were used to determine the annual number of renal colic presentations and procedural interventions undertaken for stone disease. • In Australia over the past 15 years, the annual number of procedural interventions for upper urinary tract stones has increased, primarily due to the rising number of endoscopic procedures performed. • During this period, shock wave lithotripsy numbers have remained steady whilst open and percutaneous procedures have been in decline. • The introduction of and subsequent preference for less invasive techniques has changed the management pathway of patients presenting with stone disease in Australia. • Further studies are necessary to determine whether this escalation in endoscopic procedures is due to an increase in the incidence of stone disease, earlier detection, a lower intervention threshold or a higher retreatment rate. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  10. A comparison of genetic connectivity in two deep sea corals to examine whether seamounts are isolated islands or stepping stones for dispersal

    Science.gov (United States)

    Miller, Karen J.; Gunasekera, Rasanthi M.

    2017-04-01

    Ecological processes in the deep sea are poorly understood due to the logistical constraints of sampling thousands of metres below the ocean’s surface and remote from most land masses. Under such circumstances, genetic data provides unparalleled insight into biological and ecological relationships. We use microsatellite DNA to compare the population structure, reproductive mode and dispersal capacity in two deep sea corals from seamounts in the Southern Ocean. The solitary coral Desmophyllum dianthus has widespread dispersal consistent with its global distribution and resilience to disturbance. In contrast, for the matrix-forming colonial coral Solenosmilia variabilis asexual reproduction is important and the dispersal of sexually produced larvae is negligible, resulting in isolated populations. Interestingly, despite the recognised impacts of fishing on seamount communities, genetic diversity on fished and unfished seamounts was similar for both species, suggesting that evolutionary resilience remains despite reductions in biomass. Our results provide empirical evidence that a group of seamounts can function either as isolated islands or stepping stones for dispersal for different taxa. Furthermore different strategies will be required to protect the two sympatric corals and consequently the recently declared marine reserves in this region may function as a network for D. dianthus, but not for S. variabilis.

  11. Preliminary analysis of doses to evaluate the image quality in radiographic examinations in veterinary radiology;Analise preliminar das doses para avaliacao da qualidade da imagem em exames radiograficos na radiologia veterinaria

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Ana Carolina B.C.F.; Dias, Mayara T.P.; Santos, Andrea C. [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia; Melo, Camila S.; Furquim, Tania A.C. [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2009-07-01

    This work has as objective to promote the analysis of the radiological doses and quality of the image of the technical letter used for the accomplishment of thorax and coxal radiographic examination of animals of canine and feline species. The study was accomplished in the service of Diagnosis for Image in Veterinarian Hospital of Veterinary Medicine and Zootecnia College of University of Sao Paulo, in two conventional equipment. Initially, physical features of the animals and the technique used were collected for each one of the 188 radiographic examinations of thorax and 52 examinations of coxal. The animals were placed in different groups, according to their body weight. For each group, the averages for each feature were calculated: thickness of the radiographed region, tension, electric current, time of exhibition, current product electric-time, size of the used film, presence or absence of bucky and feature of focus (narrow or thick). On the basis of the averages of group M (of lesser weights that 5kg for cats and between 10,1kg and 20kg for dogs), was executed a physical analysis of the current technical letter, using the equipment: ionization chamber (to determinate the value of kerma in air), simulator objects (representative of the thickness of the animal) and three dispositive standards of test that evaluate space resolution, resolution in low contrast and contrast-detail. The obtained images were analyzed and compared for a physicist and a radiologist medical veterinary. The results had shown that the examinations supply dose considered high for techniques used mainly for coxal. The equipment A, although to supply higher doses, presents the better images for the majority of the projections. However, the study indicates that there are not exactly reference levels, but these examinations must pass for improvement of quality of image (author)

  12. Large Format Radiographic Imaging

    International Nuclear Information System (INIS)

    Rohrer, J. S.; Stewart, Lacey; Wilke, M. D.; King, N. S.; Baker A, S.; Lewis, Wilfred

    1999-01-01

    Radiographic imaging continues to be a key diagnostic in many areas at Los Alamos National Laboratory (LANL). Radiographic recording systems have taken on many form, from high repetition-rate, gated systems to film recording and storage phosphors. Some systems are designed for synchronization to an accelerator while others may be single shot or may record a frame sequence in a dynamic radiography experiment. While film recording remains a reliable standby in the radiographic community, there is growing interest in investigating electronic recording for many applications. The advantages of real time access to remote data acquisition are highly attractive. Cooled CCD camera systems are capable of providing greater sensitivity with improved signal-to-noise ratio. This paper begins with a review of performance characteristics of the Bechtel Nevada large format imaging system, a gated system capable of viewing scintillators up to 300 mm in diameter. We then examine configuration alternatives in lens coupled and fiber optically coupled electro-optical recording systems. Areas of investigation include tradeoffs between fiber optic and lens coupling, methods of image magnification, and spectral matching from scintillator to CCD camera. Key performance features discussed include field of view, resolution, sensitivity, dynamic range, and system noise characteristics

  13. A comparative study of mud-like and coralliform calcium carbonate gallbladder stones.

    Science.gov (United States)

    Ma, Rui-Hong; Luo, Xiao-Bing; Wang, Xiao-Feng; Qiao, Tie; Huang, Hai-Yi; Zhong, Hai-Qiang

    2017-07-01

    To gain insight to underlying mechanism of the formation of calcium carbonate (CaCO 3 ) gallbladder stones, we did comparative study of stones with mud appearance and those with coralliform appearance. A total of 93 gallbladder stones with mud appearance and 50 stones with coralliform appearance were analyzed. The appearance, color, texture, and the detection of Clonorchis sinensis eggs by microscopic examination were compared between the two groups. Then, the material compositions of stones were analyzed using Fourier Transform Infrared spectroscopy and the spectrogram characteristics were compared. Moreover, microstructure characteristics of the two kinds of stones were observed and compared with Scanning Electron Microscopy. Mud-like gallbladder stones were mainly earthy yellow or brown with brittle or soft texture, while coralliform stones were mainly black with extremely hard texture, the differences between the two groups was significant (p mud-like gallbladder stones were CaCO 3 stones, and mainly aragonite; while all of the coralliform stones were CaCO 3 stones, and mainly calcite (p mud-like CaCO 3 stones was lower than that in coralliform CaCO 3 stones (p Mud-like CaCO 3 stones mainly happened to patients with cystic duct obstruction. Clonorchis sinensis infection was mainly associated with coralliform (calcite) CaCO 3 stones. Cystic duct obstruction was mainly associated with mud-like (aragonite) CaCO 3 stones. © 2017 Wiley Periodicals, Inc.

  14. Kidney stones - self-care

    Science.gov (United States)

    ... self-care; Nephrolithiasis and self-care; Stones and kidney - self-care; Calcium stones and self-care; Oxalate ... provider or the hospital because you have a kidney stone. You will need to take self-care ...

  15. Approach to Residual Kidney Stone Fragments After Shock Wave Therapy

    Directory of Open Access Journals (Sweden)

    Tumay Ižpekci

    2014-04-01

    Full Text Available For kidney stones up to 2 cm in diameter shock wave therapy (SDT is safely applied and kidney stones smaller than 5mm remaining in the kidney after treatment are regarded as clinically insignificant. Management of this condition is still controversial among clinicians. These stones in the kidney may continue to persist without any clinical symptoms or begin to cause clinical signs. In the event that the clinical symptoms are present, it requires detailed urological examination and treatment. The aim in the surgical treatment of urinary tract stones is completely stone clearance but in stones that are not infected, not causing urinary tract obstruction and without clinical symptoms medical treatment is also beneficial fort he prevention of growth and recurrence. In addition, surgical intervention is also possible for the residual stone fragments which become symptomatic during follow-up.

  16. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Bevan, J.A.

    1983-01-01

    This invention relates to radiodiagnostic agents and more particularly to a composition and method for preparing a highly effective technetium-99m-based bone scanning agent. One deficiency of x-ray examination is the inability of that technique to detect skeletal metastases in their incipient stages. It has been discovered that the methanehydroxydiphosphonate bone mineral-seeking agent is unique in that it provides the dual benefits of sharp radiographic imaging and excellent lesion detection when used with technetium-99m. This agent can also be used with technetium-99m for detecting soft tissue calcification in the manner of the inorganic phosphate radiodiagnostic agents

  17. The twelve colourful stones

    International Nuclear Information System (INIS)

    Doria, R.M.

    1983-01-01

    A dynamics with twelve colourful stones is created based on the concepts of gauge and colour. It is associated different gauge fields to the same group. A group of gauge invariant Lagrangians is established. A gauge invariant mass term is introduced. The colourful stones physical insight is to be building blocks for quarks and leptons. (Author) [pt

  18. Everybody Must Get Stones

    Directory of Open Access Journals (Sweden)

    Timothy Darvill

    2009-09-01

    Full Text Available It is now widely recognised that monument building in the fourth and third millennia cal BC often involved transporting selected blocks of preferred stone many kilometres over difficult terrain. Some structures incorporated blocks from several different sources, brought together as an ensemble in much the same way perhaps that assemblages of flint and stone axes reflect both local and distant sources. This article explores alternative models accounting for the selection of stones, contrasting those that foreground symbolic attachments and imposed meanings with those that focus on the intrinsic qualities of particular types of stone and their source. The assemblage of different stone types that accumulated at Stonehenge, Wiltshire, over a period of more than a thousand years is used as a case study.

  19. Calcium oxalate stone and gout.

    Science.gov (United States)

    Marickar, Y M Fazil

    2009-12-01

    Gout is well known to be produced by increased uric acid level in blood. The objective of this paper is to assess the relationship between gout and calcium oxalate stone formation in the humans. 48 patients with combination of gout and calcium oxalate stone problem were included. The biochemical values of this group were compared with 38 randomly selected uric acid stone patients with gout, 43 stone patients with gout alone, 100 calcium oxalate stone patients without gout and 30 controls, making a total of 259 patients. Various biochemical parameters, namely serum calcium, phosphorus and uric acid and 24-h urine calcium, phosphorus, uric acid, oxalate, citrate and magnesium were analysed. ANOVA and Duncan's multiple-range tests were performed to assess statistical significance of the variations. The promoters of stone formation, namely serum calcium (P stone patients and gouty calcium oxalate stone patients compared to the non-gouty patients and controls. Urine oxalate (P stones patients. The inhibitor urine citrate (P stone gouty patients, followed by the gouty uric acid stone formers and gouty calcium oxalate stone patients. The high values of promoters, namely uric acid and calcium in the gouty stone patients indicate the tendency for urinary stone formation in the gouty stone patients. There is probably a correlation between gout and calcium oxalate urinary stone. We presume this mechanism is achieved through the uric acid metabolism. The findings point to the summation effect of metabolic changes in development of stone disease.

  20. Radiographic imaging. 4 ed.

    International Nuclear Information System (INIS)

    Chesney, D.N.; Chesney, M.O.

    1981-01-01

    This is a revised edition of the textbook previously entitled 'Radiographic Photography' and accords with the current syllabus of training for the Diploma of the Royal College of Radiographers. The aim is a non-mathematical approach to provide a guide for the student to the knowledge and understanding of the theoretical concepts which affect the quality of radiographic image; materials and practices are also reviewed, particularly in relation to the characteristics of the radiographic image, and to processing equipment and processing areas. The subject is dealt with under the following headings: the photographic process, film materials in x-ray departments, sensitometry, storage of film materials and radiographs, intensifying screens and cassettes, film processing, developing, fixing, rinsing, washing, drying, the processing area and equipment, systems for daylight film handling, the radiographic image, management of the quality, presentation of the radiograph, light images and their recording, fluorography, some special imaging processes, e.g. xerography, copying radiographs. (U.K.)

  1. Frequency and number of ultrasound lung rockets (B-lines) using a regionally based lung ultrasound examination named vet BLUE (veterinary bedside lung ultrasound exam) in dogs with radiographically normal lung findings.

    Science.gov (United States)

    Lisciandro, Gregory R; Fosgate, Geoffrey T; Fulton, Robert M

    2014-01-01

    Lung ultrasound is superior to lung auscultation and supine chest radiography for many respiratory conditions in human patients. Ultrasound diagnoses are based on easily learned patterns of sonographic findings and artifacts in standardized images. By applying the wet lung (ultrasound lung rockets or B-lines, representing interstitial edema) versus dry lung (A-lines with a glide sign) concept many respiratory conditions can be diagnosed or excluded. The ultrasound probe can be used as a visual stethoscope for the evaluation of human lungs because dry artifacts (A-lines with a glide sign) predominate over wet artifacts (ultrasound lung rockets or B-lines). However, the frequency and number of wet lung ultrasound artifacts in dogs with radiographically normal lungs is unknown. Thus, the primary objective was to determine the baseline frequency and number of ultrasound lung rockets in dogs without clinical signs of respiratory disease and with radiographically normal lung findings using an 8-view novel regionally based lung ultrasound examination called Vet BLUE. Frequency of ultrasound lung rockets were statistically compared based on signalment, body condition score, investigator, and reasons for radiography. Ten left-sided heart failure dogs were similarly enrolled. Overall frequency of ultrasound lung rockets was 11% (95% confidence interval, 6-19%) in dogs without respiratory disease versus 100% (95% confidence interval, 74-100%) in those with left-sided heart failure. The low frequency and number of ultrasound lung rockets observed in dogs without respiratory disease and with radiographically normal lungs suggests that Vet BLUE will be clinically useful for the identification of canine respiratory conditions. © 2014 American College of Veterinary Radiology.

  2. Chest Radiographic Findings in Newly Diagnosed Pulmonary ...

    African Journals Online (AJOL)

    Five hundred newly diagnosed cases of Pulmonary Tuberculosis were treated with directly observed short-course treatment and 100 of them had chest radiographic examination done. The various chest radiographic patterns in the 100 subjects were studied and included: Fluffy exudative changes 80(80%), fibrosis 70(70%) ...

  3. Thermoluminescence of pyramid stones

    International Nuclear Information System (INIS)

    Gomaa, M.A.; Eid, A.M.

    1982-01-01

    It is the aim of the present study to investigate some thermoluminescence properties of pyramid stones. Using a few grammes of pyramid stones from Pyramids I and II, the TL glow peaks were observed at 250 and 310 0 C, respectively. The TL glow peaks of samples annealed at 600 0 C, then exposed to 60 Co γ-rays were observed at 120, 190 and 310 0 C, respectively. The accumulated dose of natural samples is estimated to be around 310 Gray (31 krad). By assuming an annual dose is 1 mGy, the estimated age of pyramid stones is 0.31 M year. (author)

  4. Thermoluminescence of pyramid stones

    Energy Technology Data Exchange (ETDEWEB)

    Gomaa, M A; Eid, A M [Atomic Energy Establishment, Cairo (Egypt)

    1982-01-01

    It is the aim of the present study to investigate some thermoluminescence properties of pyramid stones. Using a few grammes of pyramid stones from Pyramids I and II, the TL glow peaks were observed at 250 and 310/sup 0/C, respectively. The TL glow peaks of samples annealed at 600/sup 0/C, then exposed to /sup 60/Co ..gamma..-rays were observed at 120, 190 and 310/sup 0/C, respectively. The accumulated dose of natural samples is estimated to be around 310 Gray (31 krad). By assuming an annual dose is 1 mGy, the estimated age of pyramid stones is 0.31 M year.

  5. Odontogenic keratocyst radiographic features

    International Nuclear Information System (INIS)

    Nartey, N. O.; Saini, T.

    1990-01-01

    The clinical features often patients with odontogenic keratocysts were studied. One patient had Gorlin-GoJtz syndrome. A total of fourteen radiolucent lesions were observed on radiographic examination. All the fourteen lesions were diagnosed as odontogenic keratocyst after histopathclogical examination of biopsied tissue from the patients. The age at diagnosis ranged from 25-72 years with a mean age of 37.6 years. The male : female ratio was 2.3:1. Thirteen of these lesions occurred in the mandible, nine involved the mandibular third molar region. Involvement of the ramus of the mandible produced a sausage-shaped radiolucency. Cystic lesions which have been present for long periods of time showed scalloped margins, due to the regional resorption of the surrounding bone. The bony ledges present on the cortical bones simulated multilocular appearance in such cases. It was also observed that the lesions in older individuals perforated the cortical plates rather than eliciting a periostally induced bony expansion. (author)

  6. Stone fragmentation by ultrasound

    Indian Academy of Sciences (India)

    Unknown

    In the present work, enhancement of the kidney stone fragmentation by using ultrasound is studied. The cavi- ... ment system like radiation pressure balance, the power is given by ... Thus the bubble size has direct relationship with its life and.

  7. Crushed Stone Operations

    Data.gov (United States)

    Department of Homeland Security — This map layer includes crushed stone operations in the United States. These data were obtained from information reported voluntarily to the USGS by the aggregate...

  8. Radiographer commenting of trauma radiographs: a survey of the benefits, barriers and enablers to participation in an Australian healthcare setting

    International Nuclear Information System (INIS)

    Neep, Michael J.; Steffens, Tom; Owen, Rebecca; McPhail, Steven M.

    2014-01-01

    Radiographer abnormality detection systems that highlight abnormalities on trauma radiographs ('red dot' system) have been operating for more than 30 years. Recently, a number of pitfalls have been identified. These limitations initiated the evolution of a radiographer commenting system, whereby a radiographer provides a brief description of abnormalities identified in emergency healthcare settings. This study investigated radiographers' participation in abnormality detection systems, their perceptions of benefits, barriers and enablers to radiographer commenting, and perceptions of potential radiographer image interpretation services for emergency settings. A cross-sectional survey was implemented. Participants included radiographers from four metropolitan hospitals in Queensland, Australia. Conventional descriptive statistics, histograms and thematic analysis were undertaken. Seventy-three surveys were completed and included in the analysis (68% response rate); 30 (41%) of respondents reported participating in abnormality detection in 20% or less of examinations, and 26(36%) reported participating in 80% or more of examinations. Five overarching perceived benefits of radiographer commenting were identified: assisting multidisciplinary teams, patient care, radiographer ability, professional benefits and quality of imaging. Frequently reported perceived barriers included 'difficulty accessing image interpretation education', 'lack of time' and 'low confidence in interpreting radiographs'. Perceived enablers included 'access to image interpretation education' and 'support from radiologist colleagues'. A range of factors are likely to contribute to the successful implementation of radiographer commenting in addition to abnormality detection in emergency settings. Effective image interpretation education amenable to completion by radiographers would likely prove valuable in preparing radiographers for participation in abnormality detection and commenting systems in

  9. Fire effects on flaked stone, ground stone, and other stone artifacts [Chapter 4

    Science.gov (United States)

    Krista Deal

    2012-01-01

    Lithic artifacts can be divided into two broad classes, flaked stone and ground stone, that overlap depending on the defining criteria. For this discussion, flaked stone is used to describe objects that cut, scrape, pierce, saw, hack, etch, drill, or perforate, and the debris (debitage) created when these items are manufactured. Objects made of flaked stone include...

  10. Quality of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    This chapter discussed on how to get a good radiograph. There are several factors that can make good radiograph such as density of radiograph, the contrast of radiograph, definition of radiograph, the present of artifact and backscattering. All of this factor will discuss detailed on each unit of chapter with some figure, picture to make the reader understand more when read this book. And at the end, the reader will introduce with penetrameter, one of device to determine the level of quality of the radiograph. There are two type of penetrameter like wire type or holes type. This standard must be followed by all the radiographer around the world to produce the good result that is standard and more reliable.

  11. Attitudes of radiographers to radiographer-led discharge: A survey

    International Nuclear Information System (INIS)

    Lumsden, Laura; Cosson, Philip

    2015-01-01

    Background: The traditional role of the Diagnostic Radiographer in image acquisition has gradually been extended through skill-mix, particularly to include abnormality detection. Aims: This research focused on the attitudes of Radiographers to Radiographer-led Discharge (RLD), where Radiographers discharge patients with minor injuries and perform tasks previously undertaken by Accident and Emergency staff. The effects of job role, hospital type, experience and whether RLD was used in the participant's trust were examined. Method: A multiple-indicator online questionnaire assessed attitudes to RLD. Snowball sampling was used with advertisement via emails, posters and cards, containing Quick Response (QR) codes. Statement responses were coded, with reverse coding for negative statements and total scores were calculated. A higher score represented a more positive attitude. Results: 101 questionnaires were completed (an estimated 30% response rate) and the mean total score was 84/115. 95% of participants supported radiographer involvement in abnormality detection, with 46.5% selecting RLD as the preferred system for minor injuries patients vs 48.5% preferring commenting alone. Discussion: Participants were positive about extending their role through RLD and felt confident in their image interpretation abilities, though expressed concern for the legal consequences of the role and adequate pay. Generalization of the results is limited due to the possible low response rate. Conclusion: Overall, participants demonstrated positive attitudes towards RLD but they also indicate the need for appropriate payment for any additional responsibility. These findings are promising for successful implementation of RLD, though larger-scale research including radiologists, business managers, A and E staff and patients would be beneficial. - Highlights: • 101 questionnaires were completed (an estimated 30% response rate). • 95% of participants supported radiographer involvement

  12. A case report of ureteral cast stone and giant urethral stone, respectively

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ho Yung; Rhee, Song Joo; Choi, Ki Chul [School of Medicine, Jeongbug National University, Jeonju (Korea, Republic of)

    1980-12-15

    Urinary lithiasis is one of the most common disease of the urinary tract. It occurs more frequently in men than in women but rare in children and in blacks; a familial predisposition is often encountered. Ureteral stones originate in the kidney. Gravity and peristalis contribute to spontaneous passage into and down the ureter. Ureterovesical junction is the most frequent lodging site of stone. In our hospital one case of ureteral cast stone and giant urethral stone were found respectively and they were confirmed by radiological examination and surgery on Aug. 1978 and Jan. 1979. Ureteral cast stone which had been introduced and named first by Kiyonobu Tari and Kikjiro So in 1972 was very giant unusually. It may be the only one till now. Our patient was 36 years old female who has been suffered from intermittent right flank pain for 10 years. On KUB giant cylindrical radiopaque shadow was shown on RLQ extended to right minor pelvis and this was confirmed as a stone by retrograde ureteral catheterization. A stone measured 13cm x 1.5cm was found above the ureterovesical junction during operation. Follow up excretory urogram one year after operation showed no functional improvement of right kidney. Urethral stone is also unusual urinary lithiasis. This 60 years old male patient was been suffered from non-tender palpable hard mass on scrotal area and intermittent urinary retention. When urinary retention was occurred it was relieved by manipulation of the mass by himself. On plain film oval shaped giant radiopaque shadow was shown on cavernous urethral region. On urethrocystogram anterior urethra was opacified, but posterior urethra and bladder were not opacified and multiple fistulous leakage was identified. A stone measured 6.5cm x 3.5cm was found in cavernous urethra during operation.

  13. A case report of ureteral cast stone and giant urethral stone, respectively

    International Nuclear Information System (INIS)

    Song, Ho Yung; Rhee, Song Joo; Choi, Ki Chul

    1980-01-01

    Urinary lithiasis is one of the most common disease of the urinary tract. It occurs more frequently in men than in women but rare in children and in blacks; a familial predisposition is often encountered. Ureteral stones originate in the kidney. Gravity and peristalis contribute to spontaneous passage into and down the ureter. Ureterovesical junction is the most frequent lodging site of stone. In our hospital one case of ureteral cast stone and giant urethral stone were found respectively and they were confirmed by radiological examination and surgery on Aug. 1978 and Jan. 1979. Ureteral cast stone which had been introduced and named first by Kiyonobu Tari and Kikjiro So in 1972 was very giant unusually. It may be the only one till now. Our patient was 36 years old female who has been suffered from intermittent right flank pain for 10 years. On KUB giant cylindrical radiopaque shadow was shown on RLQ extended to right minor pelvis and this was confirmed as a stone by retrograde ureteral catheterization. A stone measured 13cm x 1.5cm was found above the ureterovesical junction during operation. Follow up excretory urogram one year after operation showed no functional improvement of right kidney. Urethral stone is also unusual urinary lithiasis. This 60 years old male patient was been suffered from non-tender palpable hard mass on scrotal area and intermittent urinary retention. When urinary retention was occurred it was relieved by manipulation of the mass by himself. On plain film oval shaped giant radiopaque shadow was shown on cavernous urethral region. On urethrocystogram anterior urethra was opacified, but posterior urethra and bladder were not opacified and multiple fistulous leakage was identified. A stone measured 6.5cm x 3.5cm was found in cavernous urethra during operation

  14. Diagnosis of obstruction and stone passage after extracorporeal shock-wave lithotripsy (ESWL)

    Energy Technology Data Exchange (ETDEWEB)

    Vorwerk, D.; Auffermann, W.; Fischer, N.

    1987-09-01

    78 patients with ureteral formations of stone fragments after ESWL therapy have been controlled by both ultrasound and plain abdominal films. Detection of renal stone fragments was possible similarly by sonography or radiographs. The plain films demonstrated well location and length of the 'Steinstrasse', which did not necessarily cause obstruction. Combination of sonography and plain abdominal film allows an easy follow-up after ESWL therapy, so i.v. urogramm is not acquired routinely.

  15. The diagnosis of obstruction and stone passage after extracorporeal shock-wave lithotripsy (ESWL)

    International Nuclear Information System (INIS)

    Vorwerk, D.; Auffermann, W.; Fischer, N.; Technische Hochschule Aachen

    1987-01-01

    78 patients with ureteral formations of stone fragments after ESWL therapy have been controlled by both ultrasound and plain abdominal films. Detection of renal stone fragments was possible similarly by sonography or radiographs. The plain films demonstrated well location and length of the 'Steinstrasse', which did not necessarily cause obstruction. Combination of sonography and plain abdominal film allows an easy follow-up after ESWL therapy, so i.v. urogramm is not acquired routinely. (orig.) [de

  16. Fast radiographic systems

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1984-08-01

    Industrial radiography can be performed with shorter exposure times, when instead of X-ray film with lead intensifying screens the radiographic paper with fluorescent screen is used. With paper radiography one can obtain lower material, equipment, and labor costs, shorter exposure and processing times, and easier radiation protection. The speed of the radiographic inspection can also be increased by the use of fluorometallic intensifying screens together with a special brand of X-ray film. Before accepting either of the two fast radiographic systems one must be sure that they can produce radiographs of adequate image quality. Therefore an investigation was performed on that subject using ISO wire IQI's and ASTM penetrameters. The radiographic image quality was tested for aluminium and steel up to 30 mm thick using various brands of radiographic paper and X-ray film with fluorometallic screens and comparing them with fast X-ray films with lead screens. Both systems give satisfactory results. (author)

  17. Sonographic and radiologic diagnosis of a pancreatic duct stone

    International Nuclear Information System (INIS)

    Habscheid, W.; Kulke, H.; Heidbreder, E.

    1986-01-01

    A case is reported in which asymptomatic chronic pancreatitis of initially unknown etiology was detected as result of a routine follow-up examination of a patient with membraneproliferative glomerulonephritis. Ultrasound and endoscopic cholangio-pancreatography detected a stone in the major pancreatic duct. The stone was of such size and irregular form that endoscopic extraction was impossible. (orig.) [de

  18. Sonographic and radiologic diagnosis of a pancreatic duct stone

    Energy Technology Data Exchange (ETDEWEB)

    Habscheid, W.; Kulke, H.; Heidbreder, E.

    1986-09-01

    A case is reported in which asymptomatic chronic pancreatitis of initially unknown etiology was detected as result of a routine follow-up examination of a patient with membraneproliferative glomerulonephritis. Ultrasound and endoscopic cholangio-pancreatography detected a stone in the major pancreatic duct. The stone was of such size and irregular form that endoscopic extraction was impossible.

  19. Consultant radiographers: Profile of the first generation

    International Nuclear Information System (INIS)

    Forsyth, Lesley J.; Maehle, Valerie

    2010-01-01

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  20. Consultant radiographers: Profile of the first generation

    Energy Technology Data Exchange (ETDEWEB)

    Forsyth, Lesley J., E-mail: l.forsyth@rgu.ac.u [School of Health Sciences, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom); Maehle, Valerie [Faculty of Health and Social Care, Robert Gordon University, Aberdeen, AB10 7QG (United Kingdom)

    2010-11-15

    Aim: The aim of this research is to examine the profile of first generation consultant radiographers: their demographics, educational backgrounds, qualifications and training, career experience and progression, teaching, lecturing and research activities. Method: Participant recruitment was drawn from the Society and College of Radiographers consultant radiographer group. Data collection involved a self-administered paper based and web based questionnaire. Results: Participant response rate of 55% (n = 11). Conclusions: The profile of the first consultant radiographer cohort reflects a diverse and eclectic mix. While some aspects of their development such as educational background, clinical training and skills enhancement are comparable to nurse consultants, clinical experience and employment history show some differences. Commitment to development of expert clinical skills is evident within the profile of the first generation cohort of consultant radiographers however research and leadership training are not strong features.

  1. Fasting and Urinary Stones

    Directory of Open Access Journals (Sweden)

    Ali Shamsa

    2013-11-01

    Full Text Available Introduction: Fasting is considered as one of the most important practices of Islam, and according to Prophet Mohammad, fasting is obligatory upon Muslims. The aim of this study is to evaluate the effects of fasting on urinary stones. Materials and Methods: Very few studies have been carried out on urinary stones and the effect of Ramadan fasting. The sources of the present study are Medline and articles presented by local and Muslim researchers. Meanwhile, since we are acquainted with three well-known researchers in the field of urology, we contacted them via email and asked for their professional opinions. Results: The results of studies about the relationship of urinary stones and their incidence in Ramadan are not alike, and are even sometimes contradictory. Some believe that increased incidence of urinary stones in Ramadan is related not to fasting, but to the rise of weather temperature in hot months, and an increase in humidity. Conclusion: Numerous biological and behavioral changes occur in people who fast in Ramadan and some researchers believe that urinary stone increases during this month.

  2. Radiographic constant exposure technique

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1985-01-01

    The constant exposure technique has been applied to assess various industrial radiographic systems. Different X-ray films and radiographic papers of two producers were compared. Special attention was given to fast film and paper used with fluorometallic screens. Radiographic image quality...... was tested by the use of ISO wire IQI's and ASTM penetrameters used on Al and Fe test plates. Relative speed and reduction of kilovoltage obtained with the constant exposure technique were calculated. The advantages of fast radiographic systems are pointed out...

  3. Visual simulation of radiographs

    International Nuclear Information System (INIS)

    Laguna, G.

    1985-01-01

    A method for computer simulation of radiographs has been added to the LLNL version of the solid modeler TIPS-1 (Technical Information Processing System-1). This new tool will enable an engineer to compare an actual radiograph of a solid to its computer-generated counterpart. The appearance of discrepancies between the two can be an indication of flaws in the solid object. Simulated radiographs can also be used to preview the placement of x-ray sources to focus on areas of concern before actual radiographs are made

  4. Radiation recommendation series: administratively required dental radiographs

    International Nuclear Information System (INIS)

    1981-09-01

    Administrative requirements for radiographs are found in many segments of the United States health care system. This document presents an FDA radiation recommendation on administratively required dental x-ray examinations. In general, such examinations are not requested to further the patient's dental health, but rather as a means of monitoring claims. However, the administrative use of radiographs that have been taken in the normal course of patient care is usually appropriate, as long as the patient's right to privacy is respected

  5. Tamsulosin and the spontaneous passage of ureteral stones in children: A multi-institutional cohort study

    Science.gov (United States)

    Tasian, Gregory E.; Cost, Nicholas G.; Granberg, Candace F.; Pulido, Jose E.; Rivera, Marcelino; Schwen, Zeyad; Schulte, Marion; Fox, Janelle A.

    2014-01-01

    Purpose Tamsulosin is associated with increased passage of ureteral stones in adults, but its effectiveness in children is uncertain. We determined the association between tamsulosin and the spontaneous passage of ureteral stones in children. Methods We performed a multi-institutional retrospective cohort study of children ≤ 18 years who presented between 2007 and 2012 with a ureteral stone ≤ 10 mm and were managed with tamsulosin or oral analgesics alone. The outcome was spontaneous stone passage defined as radiographic clearance and/or patient report of passage. Subjects prescribed tamsulosin were matched with subjects prescribed analgesics alone using nearest neighbor propensity score matching to adjust for treatment selection. Conditional logistic regression models were used to estimate the association between tamsulosin and spontaneous passage of ureteral stones, adjusting for stone size and location. Results Of 449 children with ureteral stones, 334 were eligible for inclusion, and complete data were available for 274 children from 4 institutions (99 tamsulosin; 175 analgesics alone). Following case matching, there were no differences in patient age, gender, weight, height, stone size, or stone location between the 99 subjects prescribed tamsulosin and the 99 propensity-score matched subjects prescribed analgesics alone. In the tamsulosin cohort, 55% of ureteral stones passed versus 44% in the analgesics alone cohort (p = 0.03). In multivariate analysis adjusting for stone size and location, tamsulosin was associated with spontaneous passage of ureteral stones (OR 3.31; 95% CI 1.49–7.34). Conclusions The odds of spontaneous passage of ureteral stones were higher in children prescribed tamsulosin versus analgesics alone. PMID:24518765

  6. Tamsulosin and spontaneous passage of ureteral stones in children: a multi-institutional cohort study.

    Science.gov (United States)

    Tasian, Gregory E; Cost, Nicholas G; Granberg, Candace F; Pulido, Jose E; Rivera, Marcelino; Schwen, Zeyad; Schulte, Marion; Fox, Janelle A

    2014-08-01

    Tamsulosin is associated with increased passage of ureteral stones in adults but its effectiveness in children is uncertain. We determined the association between tamsulosin and the spontaneous passage of ureteral stones in children. We performed a multi-institutional retrospective cohort study of patients 18 years or younger who presented between 2007 and 2012 with ureteral stones up to 10 mm and who were treated with tamsulosin or oral analgesics alone. The outcome was spontaneous stone passage, defined as radiographic clearance and/or patient report of passage. Subjects prescribed tamsulosin were matched with subjects prescribed analgesics alone, using nearest neighbor propensity score matching to adjust for treatment selection. Conditional logistic regression models were used to estimate the association between tamsulosin and spontaneous passage of ureteral stones, adjusting for stone size and location. Of 449 children with ureteral stones 334 were eligible for inclusion, and complete data were available for 274 patients from 4 institutions (99 receiving tamsulosin, 175 receiving analgesics alone). Following case matching, there were no differences in age, gender, weight, height, stone size or stone location between the 99 subjects prescribed tamsulosin and the 99 propensity score matched subjects prescribed analgesics alone. In the tamsulosin cohort 55% of ureteral stones passed, compared to 44% in the analgesics alone cohort (p=0.03). In multivariate analysis adjusting for stone size and location tamsulosin was associated with spontaneous passage of ureteral stones (OR 3.31, 95% CI 1.49-7.34). The odds of spontaneous passage of ureteral stones were greater in children prescribed tamsulosin vs analgesics alone. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Anholt Rosetta Stones

    DEFF Research Database (Denmark)

    Trempe Jr., Robert B.; Buthke, Jan

    2017-01-01

    This book records and celebrates the research finding of Anholt Island by students from Studio 2B, Arkitektskolen Aarhus, These mahogany constructions are our architectural versions of a Rosetta Stone. These are constructs that record layers of information about Anholt island through virtual...... and physical techniques, where each step and mechanic imparts and inscribes knowledge beyond the 1:1. These constructs are visual keys, used to inspire and influence all decision-making processes in a design project. These architectural Rosetta Stones document and amplify quantitative information about a site...

  8. DNA FROM ANCIENT STONE TOOLS AND BONES EXCAVATED AT BUGAS-HOLDING, WYOMING

    Science.gov (United States)

    Traces of DNA may preserve on ancient stone tools. We examined 24 chipped stone artifacts recovered from the Bugas-Holding site in northwestern Wyoming for the presence of DNA residues, and we compared DNA preservation in bones and stone tools from the same stratigraphic context...

  9. Radiation dose to the patient in several diagnostic X-ray examinations performed with conventional radiographic equipment in 3 major centers in Israel, a comparative study

    International Nuclear Information System (INIS)

    Ben-Shlomo, A.; Schlesinger, T.; Kushilevsky, A.

    1996-01-01

    In this survey we determined the effective dose to the patient in specific x-ray diagnostic procedures performed in the radiology Department and emergency rooms in 3 major hospitals (A, B, and C) in Israel. In each hospital we measured the dose area product (DAP) in a number of several major diagnostic procedures. In each hospital we carried out measurements in two X-ray departments (A1, A2. B1, B2, C1, C2). The DAP measurements were carried out using a Diamentor Dose Area Product meter (DAP). The entrance dose was obtained using calibration measurements relating the exposure at a reference distance to the imaging parameters (kVp, mAs, filtration and distance) that were recorded in the examinations. The results will be presented and compared to the reference international guidance values (authors)

  10. Radiation dose to the patient in several diagnostic X-ray examinations performed with conventional radiographic equipment in 3 major centers in Israel, a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Ben-Shlomo, A; Schlesinger, T [Israel Atomic Energy Commission, Yavne (Israel). Soreq Nuclear Research Center; Kushilevsky, A [Ben-Gurion Univ. of the Negev, Beersheba (Israel) Dept. of Biomedical Engineering

    1996-12-01

    In this survey we determined the effective dose to the patient in specific x-ray diagnostic procedures performed in the radiology Department and emergency rooms in 3 major hospitals (A, B, and C) in Israel. In each hospital we measured the dose area product (DAP) in a number of several major diagnostic procedures. In each hospital we carried out measurements in two X-ray departments (A1, A2. B1, B2, C1, C2). The DAP measurements were carried out using a Diamentor Dose Area Product meter (DAP). The entrance dose was obtained using calibration measurements relating the exposure at a reference distance to the imaging parameters (kVp, mAs, filtration and distance) that were recorded in the examinations. The results will be presented and compared to the reference international guidance values (authors).

  11. Legalities of the radiograph

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The radiograph itself plays a major role in medical malpractice cases. Also, many questions arise concerning the rights to and storage of x-ray films. These issues are addressed in this chapter. To keep the terminology simple, the word radiograph represents all imaging documentation on hard copy film (x-rays, nuclear medicine, computer-assisted studies, ultrasound, and magnetic resonance imaging)

  12. Patient dose audit of the most frequent radiographic examinations and the proposed local diagnostic reference levels in southwestern Nigeria: Imperative for dose optimisation

    Directory of Open Access Journals (Sweden)

    N.N. Jibiri

    2016-07-01

    Full Text Available Diagnostic reference levels (DRLs is a veritable tool for dose optimisation and patient protection in diagnostic radiology. However, it is essential to have information on the local situation especially in a large hospital with several units or a cluster of healthcare centres within a geographical region with several X-ray units. In the present study, entrance surface doses (ESDs were measured in twelve (12 healthcare centres consisting of 15 radiological units using thermoluminescent dosimeters (TLDs. Seven radiological procedures such as; chest PA, abdomen AP, pelvis AP, lumbar spine AP, skull AP, knee AP, and hand AP frequently carried out in Nigeria were included in the study, and their local diagnostic reference levels (LDRLs were determined. The values of the determined LDRLs were compared with established NDRLs in UK, US, Slovenia, Italy and Brazil. The LDRLs determined in the two groups (healthcare centres studied ranged from 1.78 to 3.01, 2.71 to 2.84, 2.11 to 3.79, 3.93 to 8.79, 1.06 to 1.73 and 1.10 to 1.44 mGy for chest PA, pelvis AP, lumbar spine AP, skull AP, knee AP and hand AP respectively. Large variations were found among the X-ray units studied even within the same centre. Entrance surface doses obtained in pelvis AP and lumbar spine AP in both GROUP A and were found to be lower than the NRPB-HPA 2010 review for UK, while in all other five examinations, value of the measured entrance surface dose (ESD are higher than the doses reported in the UK review. The relative higher doses found in the study are attributable to higher tube load (mAs used and indicative of the need for dose optimisation in Nigerian radiological practice.

  13. Obesometric factors associated with increased skin-to-stone distances in renal stone patients.

    Science.gov (United States)

    Allard, Christopher B; Shuster, Anatoly; Pinthus, Jehonathan H; Farrokhyar, Forough; Raees, A; Patlas, Michael; Matsumoto, Edward D; Whelan, J Paul

    2012-12-01

    Obese patients are at increased risk for renal stones as well as treatment failures due to increased skin-to-stone distances (SSD) and harder stone compositions. We investigated the relationships between obesometric parameters (body mass index [BMI], body fat distribution and obesity-related hormone levels) with SSD and stone hardness. We prospectively enrolled patients undergoing stone interventions at our institution. Computed tomography (CT) scans were analyzed; adipose tissue was identified according to Hounsfield units (HU) and separated into subcutaneous (SAT) and visceral (VAT) components. The pixels were averaged at three levels to calculate fat distribution: %VAT = (VAT)/(VAT + SAT). SSD was measured and HU were used as a surrogate for stone hardness. Obesity-related hormones leptin and adiponectin were measured by ELISA. Seventy-nine patients were prospectively enrolled. Mean BMI and %VAT were 30.02 kg/m2 and 40.13 kg/m2. Mean leptin and adiponectin levels were 17.5 ng/mL and 7.67 mcg/mL indicating high risk for metabolic consequences of obesity. Females had greater proportions of subcutaneous fat than males (%VAT 28.4 versus 46.94, p r = 0.454, p = 0.008). Obese patients with %VAT > 40 versus stone compositions as measured by HU than non-diabetics (982.86 versus 648.86, p = 0.001). Obesometric parameters such as BMI, body fat distribution, and the presence of diabetes mellitus are important considerations in the management of renal stone disease. A large proportion of subcutaneous fat, which can be estimated by physical examination, predicts SSD among obese patients and may aid treatment decisions in patients, particularly those without pre-treatment CT scans. Further studies are needed to refine the role of obesometrics in personalizing treatment decisions.

  14. Healing stone ... by infection

    OpenAIRE

    Micallef, Roderick

    2014-01-01

    Roderick Micallef has a long family history within the construction industry. He coupled this passion with a fascination with science when reading for an undergraduate degree in Biology and Chemistry (University of Malta). http://www.um.edu.mt/think/healing-stone-by-infection/

  15. Modeling Stone Columns.

    Science.gov (United States)

    Castro, Jorge

    2017-07-11

    This paper reviews the main modeling techniques for stone columns, both ordinary stone columns and geosynthetic-encased stone columns. The paper tries to encompass the more recent advances and recommendations in the topic. Regarding the geometrical model, the main options are the "unit cell", longitudinal gravel trenches in plane strain conditions, cylindrical rings of gravel in axial symmetry conditions, equivalent homogeneous soil with improved properties and three-dimensional models, either a full three-dimensional model or just a three-dimensional row or slice of columns. Some guidelines for obtaining these simplified geometrical models are provided and the particular case of groups of columns under footings is also analyzed. For the latter case, there is a column critical length that is around twice the footing width for non-encased columns in a homogeneous soft soil. In the literature, the column critical length is sometimes given as a function of the column length, which leads to some disparities in its value. Here it is shown that the column critical length mainly depends on the footing dimensions. Some other features related with column modeling are also briefly presented, such as the influence of column installation. Finally, some guidance and recommendations are provided on parameter selection for the study of stone columns.

  16. Stone composition and metabolic status.

    Science.gov (United States)

    Bibilash, B S; Vijay, Adarsh; Fazil Marickar, Y M

    2010-06-01

    This paper aims to study the correlation between biochemical risk factors of the stone former and the type of oxalate stone formed, namely calcium oxalate monohydrate (COM) and calcium oxalate dehydrate (COD). A retrospective study of 487 patients who had been attending the urinary stone clinic, Trivandrum during 1998-2007 was conducted. The stones retrieved from them were subjected to chemical analysis and FTIR spectrographic analysis. They were categorized into COM, COD, mixed COM+COD and others. Of 142 pure calcium oxalate stone patients, 87 were predominantly COM stone formers and 55 COD stone formers. Their metabolic status of 24 h urine and serum was assessed. The values of urine calcium, phosphorus, uric acid, magnesium, creatinine, oxalate, citric acid, sodium and potassium, serum values of calcium, phosphorus, uric acid, magnesium and creatinine and calculated values of creatinine clearance, tubular reabsorption of phosphate, calcium magnesium ratio and calcium oxalate ratio were recorded. Comparison was made between the COM stone group and the COD stone group. Patients forming COM stones had significantly higher mean values for urine calcium (P stone forming patients. All other values failed to show significant difference. Patients, with higher urine oxalate, formed COM stones. Those with low magnesium (which is an inhibitor) formed more of COD stones. Urine calcium was high in both groups without showing significant variation from the mean. In patients with high calcium-oxalate and calcium-magnesium ratios, there is higher chance of forming a COD stone than COM. Identification of the crystallization pattern of the calcium stone will help in selecting treatment modalities.

  17. Percutaneous nephrolithotomy versus extracorporeal shock wave lithotripsy for moderate sized kidney stones.

    Science.gov (United States)

    Deem, Samuel; Defade, Brian; Modak, Asmita; Emmett, Mary; Martinez, Fred; Davalos, Julio

    2011-10-01

    To compare the outcomes of percutaneous nephrolithotomy (PNL) and extracorporeal shock wave lithotripsy (ESWL) for moderate sized (1-2 cm) upper and middle pole renal calculi in regards to stone clearance rate, morbidity, and quality of life. All patients diagnosed with moderate sized upper and middle pole kidney stones by computed tomography (CT) were offered enrollment. They were randomized to receive either ESWL or PNL. The SF-8 quality of life survey was administered preoperatively and at 1 week and 3 months postoperatively. Abdominal radiograph at 1 week and CT scan at 3 months were used to determine stone-free status. All complications and outcomes were recorded. PNL established a stone-free status of 95% and 85% at 1 week and 3 months, respectively, whereas ESWL established a stone-free status of 17% and 33% at 1 week and 3 months, respectively. Retreatment in ESWL was required in 67% of cases, with 0% retreatment in PNL. Stone location, stone density, and skin-to-stone distance had no impact on stone-free rates at both visits, irrespective of procedure. Patient-reported outcomes, including overall physical and mental health status, favored a better quality of life for patients who had PNL performed. PNL more often establishes stone-free status, has a more similar complication profile, and has similar reported quality of life at 3 months when compared with ESWL for moderate-sized kidney stones. PNL should be offered as a treatment option to all patients with moderate-sized kidney stones in centers with experienced endourologists. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Producing quality radiographic images

    International Nuclear Information System (INIS)

    Cullinan, A.M.

    1987-01-01

    This book gives an overview of physics, equipment, imaging, and quality assurance in the radiology department. The chapters are laid out with generous use of subheads to allow for quick reference, Points are illustrated with clear, uncluttered line diagrams and well-produced images. The accompanying explanations are miniature lessons by themselves. Inserted at various points throughout the text are important notes that highlight key concepts. The chapter ''Image Evaluation and Application of Radiographic Principles'' present a systematic approach to evaluating radiographs and contains several sample radiographs to illustrate the points made

  19. Radiographic appearances in Crohn's disease. I. Accuracy of radiographic methods

    Energy Technology Data Exchange (ETDEWEB)

    Hildell, J; Lindstroem, C; Wenckert, A [Departments of Diagnostic Radiology, Pathology and Surgery, Malmoe Allmaenna Sjukhus, Malmoe, Sweden

    1979-01-01

    Preoperative films of 176 patients operated upon for Crohn's disease were reviewed and compared with microscopic findings in the resected specimens in order to assess the accuracy of the radiographic techniques used. It was found that a diagnosis of the presence and the extent of the disease was often dependent on the demonstration of minor mucosal ulcers and less marked submucosal edema. These lesions were not adequately demonstrated by any of the techniques used for small bowel examination, but were consistently revealed by the double-contrast technique used for examination of the colon.

  20. A Radiographic Study of Odontoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ho; Choi, Karp Shik [Dept. of Dental Radiology, College of Dentistry, Kyungpook National University, Daegu (Korea, Republic of)

    1998-02-15

    The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations. The obtained results were as follows: 1. Odontoma occurred the most frequently in the 2nd decade (45.4%) and occurred more frequently in males (60.5%) than in females (39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth (34.2%). 3. The type of lesions was mainly observed as compound odontoma (80.8%), and internal pattern of the complex odontoma was unevenly radiopaque (73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla (57.7%) and mandible (30.9%), and complex odontoma frequently occurred in anterior portion of maxilla (34.8%) and posterior portion of mandible (30.5%). 5. The effects on adjacent teeth were impaction of teeth (71.7%) and prolonged retention of deciduous teeth (31.7%). 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) amd mandible (19.2%), but root resorption of the adjacent teeth were not seen. 7. The boundary to adjacent structure was well-defined , the lesions appear as radiopaque mass with radiolucent rim.

  1. Selected findings in radiographic cardiac examinations

    International Nuclear Information System (INIS)

    Longin, F.

    1978-01-01

    The author describes the use of X-rays for the investigation of heart size, shape, and position and for the diagnosis of pathological changes (secondary vitin, connatal vitia, and cardiomyopathies). (VJ) [de

  2. Radiographic examination methods for fuel pins

    International Nuclear Information System (INIS)

    Smirnov, V.P.; Dvoretskii, V.G.

    1987-11-01

    To study the fast neutron reactor fuel pins structure the NIIAR Institute used x diffraction, neutronic radiography and autoradiographies. The two first methods are used for internal macrostructure studies, the third method for the plutonium and uranium radial distribution. These methods and the main results are indicated in this document [fr

  3. A Tutorial for Performing a Radiographic Examination

    Science.gov (United States)

    2017-03-01

    translatable. The area of the measurement should encompass the same materials and thicknesses for an accurate measurement. In the case of a weld inspection...digital image, a line pair gauge and/or duplex wire gauge can be used (ref. 6). These tools are similar in that they are small wires aligned in a...measure of what the smallest detectable feature is. In general practice, the duplex wire gauge can be more accurate and is easier to use since a

  4. Emergency extracorporeal shock wave lithotripsy (ESWL) for obstructing ureteral stones.

    Science.gov (United States)

    Tligui, M; El Khadime, M R; Tchala, K; Haab, F; Traxer, O; Gattegno, B; Thibault, P

    2003-05-01

    To evaluate emergency treatment of obstructing ureteral stones by in situ extracorporeal shock wave lithotripsy (ESWL) during acute renal colic. From January 1994 to February 2000, 200 patients (mean age: 42 years) were treated by ESWL (EDAP LT-02) for obstructing ureteral stones causing acute renal colic refractory to medical treatment or recurring within 24hours of such treatment. Stones were visualised by fluoroscopic imaging and/or ultrasound. Follow-up included radiological and/or ultrasound examinations and lasted three months. Mean stone size was 7mm (3-20mm). At three months, 164/200 (82%) patients were stone-free. This rate ranged from 79% to 83% according to the location of the stone, and from 75% to 86% according to the size of the stone. These differences in rate were not significant. Two or three ESWL sessions were required in 79 patients. ESWL was well tolerated in 90% of patients. The only complication was a case of pyelonephritis requiring the placement of a JJ stent, administration of antibiotics, and distant ureteroscopy. The 36 patients, in whom ESWL failed, underwent ureteroscopy (n=23) or lithotripsy with a Dornier machine (n=13). Non-deferred ESWL for acute renal colic secondary to obstructing ureteral stones has a satisfactory success rate and very low morbidity.

  5. Rapidly processable radiographic material

    International Nuclear Information System (INIS)

    Brabandere, L.A. de; Borginon, H.A.; Pattyn, H.A.; Pollet, R.J.

    1981-01-01

    A new rapidly processable radiographic silver halide material is described for use in mammography and non-destructive testing of industrial materials. The radiographic material is used for direct exposure to penetrating radiation without the use of fluorescent-intensifying screens. It consists of a transparent support with a layer of hydrophilic colloid silver halide emulsion on one or both sides. Examples of the preparation of three different silver halide emulsions are given including the use of different chemical sensitizers. These new radiographic materials have good resistance to the formation of pressure marks in rapid processing apparatus and they have improved sensitivity for direct exposure to penetrating radiation compared to conventional radiographic emulsions. (U.K.)

  6. Radiographic manifestations of hypochondroplasia

    Energy Technology Data Exchange (ETDEWEB)

    Heselson, N G; Cremin, B J [Groote Schuur Hospital, Cape Town (South Africa); Beighton, P

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations.

  7. The twelve colourful stones

    International Nuclear Information System (INIS)

    Doria, R.M.

    1984-01-01

    The gauge symmetry is extended. It is associated differents matter and gauge fields to the same group. A group of gauge invariant Lagrangians is established. A gauge invariant mass term is introduced. A massive Yang Mills is obtained. A dynamics with twelve colourful stones is created based on the concepts of gauge and colour. Structures identified as quarks and leptons are generated. A discussion about colour meaning is presented. (Author) [pt

  8. Anholt Rosetta Stones

    DEFF Research Database (Denmark)

    Trempe Jr., Robert B.; Buthke, Jan

    2017-01-01

    This book records and celebrates the research finding of Anholt Island by students from Studio 2B, Arkitektskolen Aarhus, These mahogany constructions are our architectural versions of a Rosetta Stone. These are constructs that record layers of information about Anholt island through virtual and ...... on Anholt Island through qualitative means. They are tools for uncovering realities previously unseen or unimagined through the manipulation of data via personal experience....

  9. Lessons from a Stone Farm

    Science.gov (United States)

    Kavanagh, John P.; Rao, P. Nagaraj

    2007-04-01

    The stone farm is a system for measuring macroscopic stone growth of 12 calcium stones simultaneously. It is based on mixed suspension, mixed product removal continuous crystallization principles and the stones are grown continuously for about 500 hours or more. The growth of the stones follows a surface area dependent pattern and the growth rate constants are very similar irrespective of whether the stating materials are fragments of human stone or pieces of marble chip. Increasing citrate from 2mM to 6mM caused a significant growth inhibition which persisted in the presence of urinary macromolecules. Phytate was a very effective inhibitor (about 50% at sub-μM concentrations) but the effective concentration was increased by an order of magnitude in the presence of urinary macromolecules. The effective concentration for inhibition in a crystallization assay was a further two orders of magnitude higher. Urinary macromolecules or almost whole urine were also strongly inhibitory although neither human serum albumin nor bovine mucin had any great effect. The relationship between the size distribution of crystals in suspension and the stone enlargement rate suggests that the primary enlargement mechanism for these in vitro stones is through aggregation. The stone farm is a powerful tool with which to study crystallization inhibitors in a new light. Some differences between inhibition of crystallization and inhibition of stone growth have emerged and we have obtained quantitative evidence on the mechanism of stone enlargement in vitro. Our findings suggest that the interface between crystals in suspension and the stone surface is the key to controlling stone enlargement.

  10. Australian rural radiographers' perspectives on disclosure of their radiographic opinion to patients

    International Nuclear Information System (INIS)

    Squibb, Kathryn; Bull, Rosalind M.; Smith, Anthony; Dalton, Lisa

    2015-01-01

    The role of Australian rural radiographers in radiographic interpretation, communication and disclosure of their radiographic opinion with a specific focus on plain film radiography was examined in a two phase, exploratory interpretive study. Data were collected using questionnaires and interviews and analysed thematically. This reports one of the key themes identified in the thematic data analysis. ‘Disclosure of Radiographic Opinion to Patients’ comprises the three interrelated sub-themes Acting Ethically, Selective Disclosure and Filtered Truth. It is wholly concerned with the ways in which rural radiographers choose to disclose their radiographic opinion to patients. Without a clear picture of where they stand medico-legally, rural radiographers draw on experience and a strong ethical framework as the basis for these complex decisions. Rural radiographers frame their disclosures to patients in a manner that is governed by the diagnostic, therapeutic and emotional impact the information disclosed may have on the patient. Disclosure to patients was found to be selective, often diagnostically vague and ethically filtered

  11. Nanobacteria: An Infectious Cause for Salivary Stone Formation and Recurrence

    Directory of Open Access Journals (Sweden)

    Amr A El Badry

    2010-01-01

    Full Text Available Nanobacteria (NB contribute to pathological calcification in the human and animal body. It has been isolated from salivary stones and suggested that it may act as a nucleus for the initiation of these stones. In the present study, we examined its role in the recurrent salivary gland stones using immunodetection with NB-specific monoclonal antibodies and scanning electron microscopy (SEM hoping to provide a method for preventing the recurrence of these stones in the patient that has suffered from salivary stones. Our study comprised 30 patients with recurrent salivary gland stones (group I and 30 patients with salivary gland stones for the first time (group II, in addition to 30 normal controls (group III. We could detect 100–500 nm nanoparticles in 24/30 (80% cases in group I with significant difference <0.05 and <0.01 when compared with group II and group III in which they were detected in 19/30 (63.3% and 6/30 (20% respectively. Also there was a significant difference <0.05 between group II and group III. We proposed that salivary stone formation is a nanobacterial disease initiated by bacterial infection. This bacteria may play an important role in the recurrence of salivary stone. So the use of calcium chelator, ethylene diamine tetra acetic acid (EDTA, before or in combination with the suitable antibiotic that is given in an amount effective to inhibit or prevent the growth and development of nanobacteria may eradicate these stones and prevent their recurrence.

  12. Accuracy of radiographer reporting of paediatric brain CT

    International Nuclear Information System (INIS)

    Brandt, Andrew; Louw, Brand; Dekker, Gerrit; Andronikou, Savvas; Wieselthaler, Nicki; Kilborn, Tracy; Bertelsman, Jessica; Dreyer, Catherine

    2007-01-01

    Radiographer reporting has been studied for plain films and for ultrasonography, but not in paediatric brain CT in the emergency setting. To study the accuracy of radiographer reporting in paediatric brain CT. We prospectively collected 100 paediatric brain CT examinations. Films were read from hard copies using a prescribed tick sheet. Radiographers with 12 years' and 3 years' experience, respectively, were blinded to the history and were not trained in diagnostic film interpretation. The radiographers' results were compared with those of a consultant radiologist. Three categories were defined: abnormal scans, significant abnormalities and insignificant abnormalities. Both radiographers had an accuracy of 89.5% in reading a scan correctly as abnormal, and radiographer 1 had a sensitivity of 87.8% and radiographer 2 a sensitivity of 96%. Radiographer 1 had an accuracy in detecting a significant abnormality of 75% and radiographer 2 an accuracy of 48.6%, and the sensitivities for this category were 61.6% and 52.9%, respectively. Results for detecting the insignificant abnormalities were poorer. Selected radiographers could play an effective screening role, but lacking the sensitivity required for detecting significant abnormality, they could not be the final diagnostician. We recommend that the study be repeated after both radiographers have received formal training in interpretation of paediatric brain CT. (orig.)

  13. Association between dental pulp stones and calcifying nanoparticles.

    Science.gov (United States)

    Zeng, Jinfeng; Yang, Fang; Zhang, Wei; Gong, Qimei; Du, Yu; Ling, Junqi

    2011-01-07

    The etiology of dental pulp stones, one type of extraskeletal calcification disease, remains elusive to date. Calcifying nanoparticles (CNPs), formerly referred to as nanobacteria, were reported to be one etiological factor in a number of extraskeletal calcification diseases. We hypothesized that CNPs are involved in the calcification of the dental pulp tissue, and therefore investigated the link between CNPs and dental pulp stones. Sixty-five freshly collected dental pulp stones, each from a different patient, were analyzed. Thirteen of the pulp stones were examined for the existence of CNPs in situ by immunohistochemical staining (IHS), indirect immunofluorescence staining (IIFS), and transmission electron microscope (TEM). The remaining 52 pulp stones were used for isolation and cultivation of CNPs; the cultured CNPs were identified and confirmed via their shape and growth characteristics. Among the dental pulp stones examined in situ, 84.6% of the tissue samples staines positive for CNPs antigen by IHS; the corresponding rate by IIFS was 92.3 %. In 88.2% of the cultured samples, CNPs were isolated and cultivated successfully. The CNPs were visible under TEM as 200-400 nm diameter spherical particles surrounded by a compact crust. CNPs could be detected and isolated from a high percentage of dental pulp stones, suggesting that CNPs might play an important role in the calcification of dental pulp.

  14. Dental radiographic units - radiation safety and patient doses

    International Nuclear Information System (INIS)

    Nagpal, J.S.; Varadharajan, Geetha

    2001-01-01

    Three models of dental radiographic machines have been examined for radiation safety. Using TL dosemeters, doses received by the patients at chest level and the gonads have been estimated. Care should be taken to shield gonads during dental radiographic examinations. (author)

  15. The demonstration of gall stones by sonography and radiography

    International Nuclear Information System (INIS)

    Gladisch, R.; Deininger, H.K.; Staedtische Kliniken Darmstadt

    1983-01-01

    Eighty-seven unselected gall stones were examined radiologically and by ultrasound in vitro. No relationship of diagnostic value could be established between the amount of calcification and stone demonstration, the sonogram being influenced by the size of the stone, its surface contour and its position in the ultrasound beam. Sonography is therefore not suitable for selecting those patients on whom litholysis could be carried out. Sonography appears to be useful only in a negative way by establishing the exact size of the concretion. (orig.) [de

  16. The economics of stone disease.

    Science.gov (United States)

    Canvasser, Noah E; Alken, Peter; Lipkin, Michael; Nakada, Stephen Y; Sodha, Hiren S; Tepeler, Abdulkadir; Lotan, Yair

    2017-09-01

    The rising prevalence of kidney stone disease is associated with significant costs to healthcare systems worldwide. This is in part due to direct procedural and medical management costs, as well as indirect costs to health systems, patients, and families. A number of manuscripts evaulating the economics of stone disease have been published since the 2008s International Consultation on Stone Disease. These highlight costs associated with stone disease, including acute management, surgical management, and medical management. This work hopes to highlight optimization in care by reducing inefficient treatments and maximizing cost-efficient preventative strategies.

  17. Ultrasonic propulsion of kidney stones.

    Science.gov (United States)

    May, Philip C; Bailey, Michael R; Harper, Jonathan D

    2016-05-01

    Ultrasonic propulsion is a novel technique that uses short bursts of focused ultrasonic pulses to reposition stones transcutaneously within the renal collecting system and ureter. The purpose of this review is to discuss the initial testing of effectiveness and safety, directions for refinement of technique and technology, and opinions on clinical application. Preclinical studies with a range of probes, interfaces, and outputs have demonstrated feasibility and consistent safety of ultrasonic propulsion with room for increased outputs and refinement toward specific applications. Ultrasonic propulsion was used painlessly and without adverse events to reposition stones in 14 of 15 human study participants without restrictions on patient size, stone size, or stone location. The initial feasibility study showed applicability in a range of clinically relevant situations, including facilitating passage of residual fragments following ureteroscopy or shock wave lithotripsy, moving a large stone at the ureteropelvic junction with relief of pain, and differentiating large stones from a collection of small fragments. Ultrasonic propulsion shows promise as an office-based system for transcutaneously repositioning kidney stones. Potential applications include facilitating expulsion of residual fragments following ureteroscopy or shock wave lithotripsy, repositioning stones prior to treatment, and repositioning obstructing ureteropelvic junction stones into the kidney to alleviate acute renal colic.

  18. Villamayor stone (Golden Stone) as a Global Heritage Stone Resource from Salamanca (NW of Spain)

    Science.gov (United States)

    Garcia-Talegon, Jacinta; Iñigo, Adolfo; Vicente-Tavera, Santiago

    2013-04-01

    Villamayor stone is an arkosic stone of Middle Eocene age and belongs to the Cabrerizos Sandstone Formation that comprising braided fluvial systems and paleosoils at the top of each stratigraphic sequence. The sandstone is known by several names: i) the Villamayor Stone because the quarries are located in Villamayor de Armuña village that are situated at 7 km to the North from Salamanca city; ii) the Golden Stone due to its patina that produced a ochreous/golden color on the façades of monuments of Salamanca (World Heritage City,1988) built in this Natural stone (one of the silicated rocks utilised). We present in this work, the Villamayor Stone to be candidate as Global Heritage Stone Resource. The Villamayor Stone were quarrying for the construction and ornamentation of Romanesque religious monuments as the Old Cathedral and San Julian church; Gothic (Spanish plateresc style) as the New Cathedral, San Esteban church and the sculpted façade of the Salamanca University, one of the oldest University in Europe (it had established in 1250); and this stone was one of the type of one of the most sumptuous Baroque monuments is the Main Square of the its galleries and arcades (1729). Also, this stone was used in building palaces, walls and reconstruction of Roman bridge. Currently, Villamayor Stone is being quarried by small and family companies, without a modernized processing, for cladding of the façades of the new buildings until that the construction sector was burst (in 2008 the international economic crisis). However, Villamayor Stone is the main stone material used in the city of Salamanca for the restoration of monuments and, even in small quantities when compared with just before the economic crisis, it would be of great importance for future generations protect their quarries and the craft of masonry. Villamayor Stone has several varieties from channels facies to floodplains facies, in this work the selected varieties are: i) the fine-grained stone

  19. A radiographic study of pediatric ulnar anatomy.

    Science.gov (United States)

    Cravino, Mattia; Oni, Julius K; Sala, Debra A; Chu, Alice

    2014-01-01

    The adult ulna has a unique bony architecture that has been described in the literature, but, to the best of our knowledge, the ulnar anatomy in children has not been described. We examined 75 anteroposterior (AP) and 64 lateral radiographs (29 were bilateral) of 50, 0.5- to 11-year-old, healthy children's forearms. On AP radiographs, the total ulnar length, the ulnar proximal angle, the ulnar distal angle, and the distance between each angle from the tip of the triceps insertion; and, on lateral radiographs, the ulnar length and bow deviation were measured. The correlation between age and radiographic measurements, differences based on sex, differences compared with adults' measurements, and interobserver/intraobserver reliability were assessed. Age had a very strong/strong positive correlation with length/distance measurements on both AP and lateral radiographs. Only AP ulnar distal angle was significantly different between sexes (females > males). Compared with the adult ulnar studies, the AP proximal angle in children is significantly smaller and the location of this angle is significantly more distal. Interobserver and intraobserver reliability were very good for length/distance measurements on AP and lateral radiographs. The knowledge of pediatric ulnar anatomy could be helpful in the treatment of forearm deformities due to multiple hereditary exostosis and osteogenesis imperfecta, and in the treatment of ulnar fractures, particularly in Monteggia variants, where restoration of the correct forearm anatomy is essential to obtain good clinical and functional results. Study of diagnostic test, Level II.

  20. Radiographic aspects of xeroradiography

    International Nuclear Information System (INIS)

    Rao, G.U.V.; Fatouros, P.P.

    1980-01-01

    The quality of a conventional radiographic image can be characterized in terms of five basic parameters; density, contrast, latitude, resolution and noise. Since xeroradiographic images exhibit very limited broad area contrasts, and image formation is predominantly due to edge enhancement, a straightforward description of image quality using the same five parameters is not adequate. A detailed study was made of the radiographic aspects of xeroradiography with special reference to mammography, and a summary of major findings to date with appropriate references to published papers is presented

  1. A radiologic study of salivary stones

    International Nuclear Information System (INIS)

    Cho, Hyo Suck; Ahn, Hyung Kyu

    1986-01-01

    The author examined fifty cases of sialolithiasis diagnosed in the Dept. of Oral Radiology in SNUH by conventional radiography and sialography, and patient's age, sex, location, radiodensity, numbers, shapes, and relation with ducts a nd parenchymas. The results of this study were as follows: 1. The average age of patients was 38.6 years in submandibular sialolithiasis, and 39.2 years in parotid sialolithiasis. 2. There was slightly higher incidence in males (58.0%) than in females (42.0%). 3. Salivary stones were found to be much more in the submandibular gland and duct (82.0%) than in the parotid gland and duct (18.0%). 4. Of 62 submandibular salivary stones, 33 (53.2%) occurred in the main duct, 25 (40.3%) occurred in the hilum, and 4 (6.5%) occurred in the parenchyma. Of 18 parotid salivary stones, 9(50.0%) occurred in the main duct, 5(27.8%) occurred in the parenchyma, and 4 (22 .2%) occurred in the hilum. 5. Of the submandibular salivary stones, the number of radiopaque type was 45 (75.8%), and the number of radiolucent type was 17 (24.2%). Of the parotid salivary stones, the number of radiopaque type was 12 (66.7%), and the number of radiolucent type was 6 (33.3%). 6. The single type was 30 cases (73.2%) in submandibular gland, 6 cases (66.7%) in parotid gland, and the multiple type was 11 cases (26.8%) in submandibular grand, and 3 cases (33. 3%) in parotid gland. 7. Round shape was 35 cases (43.8%), ovoid shape was 22 cases (27.5%), irregular shape was 17 cases (21.3%), and cylindrical shape was 6 cases (7.5%).

  2. A study on the industrialization of building stones and industrial stone crafts - Study on the causes of stone contaminations

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, Jeon Ki; Lee, Han Yeang [Korea Institute of Geology Mining and Materials, Taejon (Korea, Republic of)

    1996-12-01

    Causes of building stone contamination are acid rains in polluted areas, iron bearing minerals in stone itself, salts, sealants, cutting and grinding processes in stone factory and steel compounds structures such as stone anchors, bolts, rain culvert and guide frames. Contaminations on the building stone surface of Sejong culture center can be found around floor stones, stair stones, parterre stones, pillar stones and other outdoor stone panels. The parterre stones are contaminated by white tarnishes and rust flows are occurred on the surface of pillar stones and outdoor stone panels around entrance. Black tarnishes are cumulated on the pillar stones and other outdoor decorated stone panels and change the original granite color. Causes of building stone contaminations from Sejong culture center are wet method to attach stone panels, rust from steel compounds structures and air pollutants. Cement and mortar used from wet method react with sulfur dioxides in polluted air and from fine calcite crystals (white tarnish). Rusts from steel compounds structures such as rainwater culvert and steel guide frames can move to the stone surface by rain and leave rust flows on it. Pollutants (tar compounds, carbons, dusts, etc.) in air are cumulated with humidity on the stone surface and change color from white granite color to dusty dark color. Historical stone sculptures such as man and animal shaped stone crafts, tombstones, square stone tables in front of a tomb and guide and circumference stones around tomb in Royal Tombs (Donggu rung, Yung rung, Seoou rung and Hunin rung) distributed in Kyunggi province are contaminated by various moss and air pollutants and its original colors are deeply changed. (author). 21 refs., 11 tabs., 22 figs.

  3. Distal renal tubular acidosis in recurrent renal stone formers

    DEFF Research Database (Denmark)

    Osther, P J; Hansen, A B; Røhl, H F

    1989-01-01

    Renal acidification ability was examined in 90 recurrent renal stone formers, using fasting morning urinary pH levels followed by a short ammonium chloride loading test in subjects with pH levels above 6.0. Fifteen patients (16.6%) revealed a distal renal tubular acidification defect: one patient......, this has important therapeutic implications. The pathological sequence in renal stone formers with dRTA is discussed....

  4. Prognostic radiographic aspects of spondylolisthesis

    International Nuclear Information System (INIS)

    Saraste, H.; Brostroem, L.A.; Aparisi, T.

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films frompatients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping. (orig.)

  5. Prognostic radiographic aspects of spondylolisthesis

    Energy Technology Data Exchange (ETDEWEB)

    Saraste, H; Brostroem, L A; Aparisi, T

    1984-01-01

    A series of 202 patients (133 men, 69 women) with lumbar spondylolysis were examined radiographically on two occasions, first at the time of diagnosis and later at a follow-up, after an observation period of 20 years or more. The films from patients in groups without and with moderate and severe olisthesis were evaluated with respect to variables describing lumbosacral lordosis, wedging of the spondylolytic vertebra, lengths of the transverse processes and iliolumbar ligaments, disk height, progression of slipping, and influence on measured olisthesis of lumbar spine flexion and extension at the radiographic examination. The evaluation was made with special attention to possible signs which could be predictive for the prognosis of vertebral slipping. Progression of slipping did not differ between patients diagnosed as adults or adolescents. Reduction of disk height was correlated to the degree of slipping present at the initial examination and to the progression of olisthesis. Flexion and extension of the lumbar spine did not modify the degree of olisthesis. Data concerning the lengths of the transverse processes and the iliolumbar ligaments, and lumbar lordosis, cannot be used for prognostic purposes. The lumbar index reflecting the degree of wedge deformity of the spondylolytic vertebra was shown to be the only variable of prognostic value for the development of vertebral slipping.

  6. Recumbent Stone Circles

    Science.gov (United States)

    Ruggles, Clive L. N.

    During the 1970s and early 1980s, British archaeoastronomers were striving to bridge the interpretative gulf between the "megalithic observatories" of Alexander Thom and an archaeological mainstream that, generally speaking, was hostile to any mention of astronomy in relation to the megalithic monuments of Neolithic and Early Bronze Age Britain. The Scottish recumbent stone circles (RSCs) came to represent an example where sounder methodology could overcome many of the data selection issues that had beset earlier studies and, with due restraint, produce credible interpretations. Systematic studies of their orientations consistently concluded that the RSCs had a strong lunar connection, and it was widely envisaged that they were the setting for ceremonies associated with the appearance of the moon over the recumbent stone. Other evidence such as the presence of white quartz and the spatial distribution of cupmarks appeared to back up this conclusion. New archaeological investigations since 1999 have challenged and modified these conclusions, confirming in particular that the circles were built to enclose cairns rather than to demarcate open spaces. Yet the restricted pattern of orientations of these structures could only have been achieved by reference to the basic diurnal motions of the skies, and orientation in relation to simple observations of the midsummer moon remains the most likely reading of the alignment evidence taken as a whole. On the other hand, a consideration of the broader context, which includes the nearby Clava cairns, highlights instead the symbolic importance of the sun.

  7. Hyaluronan and Stone Disease

    Science.gov (United States)

    Asselman, Marino

    2008-09-01

    Kidney stones cannot be formed as long as crystals are passed in the urine. However, when crystals are retained it becomes possible for them to aggregate and form a stone. Crystals are expected to be formed not earlier than the distal tubules and collecting ducts. Studies both in vitro and in vivo demonstrate that calcium oxalate monohydrate crystals do not adhere to intact distal epithelium, but only when the epithelium is proliferating or regenerating, so that it possesses dedifferentiated cells expressing hyaluronan, osteopontin (OPN) and their mutual receptor CD44 at the apical cell membrane. The polysaccharide hyaluronan is an excellent crystal binding molecule because of its negative ionic charge. We hypothesized that the risk for crystal retention in the human kidney would be increased when tubular cells express hyaluronan at their apical cell membrane. Two different patient categories in which nephrocalcinosis frequently occurs were studied to test this hypothesis (preterm neonates and kidney transplant patients). Hyaluronan (and OPN) expression at the luminal membrane of tubular cells indeed was observed, which preceded subsequent retention of crystals in the distal tubules. Tubular nephrocalcinosis has been reported to be associated with decline of renal function and thus further studies to extend our knowledge of the mechanisms of retention and accumulation of crystals in the kidney are warranted. Ultimately, this may allow the design of new strategies for the prevention and treatment of both nephrocalcinosis and nephrolithiasis in patients.

  8. Endoscopic Stone Measurement During Ureteroscopy.

    Science.gov (United States)

    Ludwig, Wesley W; Lim, Sunghwan; Stoianovici, Dan; Matlaga, Brian R

    2018-01-01

    Currently, stone size cannot be accurately measured while performing flexible ureteroscopy (URS). We developed novel software for ureteroscopic, stone size measurement, and then evaluated its performance. A novel application capable of measuring stone fragment size, based on the known distance of the basket tip in the ureteroscope's visual field, was designed and calibrated in a laboratory setting. Complete URS procedures were recorded and 30 stone fragments were extracted and measured using digital calipers. The novel software program was applied to the recorded URS footage to obtain ureteroscope-derived stone size measurements. These ureteroscope-derived measurements were then compared with the actual-measured fragment size. The median longitudinal and transversal errors were 0.14 mm (95% confidence interval [CI] 0.1, 0.18) and 0.09 mm (95% CI 0.02, 0.15), respectively. The overall software accuracy and precision were 0.17 and 0.15 mm, respectively. The longitudinal and transversal measurements obtained by the software and digital calipers were highly correlated (r = 0.97 and 0.93). Neither stone size nor stone type was correlated with error measurements. This novel method and software reliably measured stone fragment size during URS. The software ultimately has the potential to make URS safer and more efficient.

  9. Grasping the Formless in Stones

    DEFF Research Database (Denmark)

    Aktor, Mikael

    2017-01-01

    and the repertoire of used forms. The chapter demonstrates that neither anthropomorphic perceptions nor the agency of the stone material alone make up the ritual aesthetics in which the stones are involved. Rather, applying concepts from landscape phenomenology and cognitive theories including the role of material...

  10. Initial image interpretation of appendicular skeletal radiographs: A comparison between nurses and radiographers

    International Nuclear Information System (INIS)

    Piper, Keith J.; Paterson, Audrey

    2009-01-01

    Purpose: To examine the effect of a short training programme on nurses and radiographers, exploring differences between their performance before and after training. Method: Twenty-two nurses and 18 radiographers interpreted 20 trauma radiographs of the appendicular skeleton before and after training. Normal and abnormal cases of a discriminatory nature were included. Total score, sensitivity and specificity values were calculated for each participant by comparison with an agreed expected answer. The area under the curve (AUC) was analysed using alternate free-response receiver operating characteristic (AFROC) methodology. Results: Significant differences were demonstrated between the total scores achieved by the two groups (pre-training: p = 0.007, post-training: p = 0.04). After training, the mean score increased significantly for both groups (p < 0.001). No significant difference was found between the radiographers mean pre-training scores and the nurses mean post-training scores (p = 0.66). Sensitivity for both groups increased following training, significantly so for the nurses (nurses: p < 0.001, radiographers: p = 0.06). Specificity reduced significantly after training for the nurses (p < 0.001), and increased for the radiographers but not significantly (p = 0.085). After training, there was no significant difference between the two groups in terms of sensitivity (p = 0.09) but specificity was significantly higher for the radiographers (p < 0.001). The radiographers achieved higher pre-training AUC values than the nurses (p = 0.04), although a difference remained after training this did not achieve statistical significance (p = 0.15). The AUC values increased significantly after training for both groups (nurses: p = 0.012, radiographers: p = 0.004) and again there was no significant difference between the radiographers pre-training performance and the nurses post-training performance (p = 0.62). Conclusion: Improvement after training was seen in both groups

  11. Frequency and factors effecting non clearance of lower pole renal stones

    International Nuclear Information System (INIS)

    Ullah, A.; Zubair, M.; Khan, N.; Malik, A.

    2015-01-01

    Renal stone disease is a major health hazard in Pakistan and extra-corporeal shockwave lithotripsy is one of comprehensive method used to treat these stones. The aim of this study is to determine the frequency of factors affecting the non-clearance of stone fragments of lower pole renal stone after extra corporeal shockwave lithotripsy. The study was done with the objective to determine the frequency the spatial anatomical factors which can influence the non-clearance of lower pole stone fragments after ESWL. Methods: One and nineteen (119) patients with lower pole renal stone less than 10 mm were subjected to maximum 3 sessions of extracorporeal shock wave lithotripsy. KUB radiographs, ultrasonography and intravenous urography were used as investigative tools for lower pole renal calyceal anatomy. X ray KUB and ultrasound were done after a week for clearance. Data was analysed with the help of SPSS version 10.0 and presented in the forms of tables and graphs. Results: There were 77 (64.71%) males and 42 (35.29%) females. Infundibulo-pelvic angle (IPA)>40 degree was present in 93 (78.15%), Infundibular length (IL) <22 mm in 107 (89.92%) and Infundibular width (IW) >4 mm was present in 100 (84.03%) patients. The frequency of stone non clearance was noted in 31 (26.05%). Infundibulo-pelvic angle (IPA)>40 degree (p=0.000), Infundibular length (IL)<22 mm (p=0.001) and Infundibular width (IW)>4 mm (p=0.046) were significant variables affecting stone clearance. Conclusion: The frequency of non-clearance of lower calyx of kidney stone is 26.05%. The clearance of fragments of the lower calyx kidney stones is affected by three spatial anatomical factors, i.e., Infundibulopelvic angle, Infundibular width and infundibular length. (author)

  12. [Transparency regime: semiotics of radiographical images in urological diagnostics].

    Science.gov (United States)

    Martin, M; Fangerau, H

    2012-10-01

    Shortly after Röntgen discovered x-rays urology became one of the main test fields for the application of this new technology. Initial scepticism among physicians, who were inclined to cling to traditional manual methods of diagnosing, was replaced by enthusiasm for radiographic technologies and the new method soon became the standard in, for example the diagnosis of concrements. Patients favoring radiographic procedures over the use of probes and a convincing documentation of stones in radiograms were factors that impacted the relatively rapid integration of radiology into urology. The radiographic representation of soft tissues and body cavities was more difficult and the development of contrast agents in particular posed a serious problem. Several patients died during this research. A new diagnostic dimension was revealed when radiography and cystography were combined to form the method of retrograde pyelography. However, the problem of how urologists could learn how to read the new images remained. In order to allow trainee physicians to practice interpreting radiograms atlases were produced which offered explanatory texts and drawings for radiographic images of the kidneys, the bladder etc. Thus, urologists developed a self-contained semiotics which facilitated the appropriation of a unique urological radiographical gaze.

  13. Matching hand radiographs

    NARCIS (Netherlands)

    Kauffman, J.A.; Slump, Cornelis H.; Bernelot Moens, H.J.

    2005-01-01

    Biometric verification and identification methods of medical images can be used to find possible inconsistencies in patient records. Such methods may also be useful for forensic research. In this work we present a method for identifying patients by their hand radiographs. We use active appearance

  14. Stabilized radiographic scanning agent

    International Nuclear Information System (INIS)

    Fawzi, M.B.

    1979-01-01

    A stable composition useful in preparation of technetium-99m-based radiographic scanning agents has been developed. The composition contains a stabilizing amount of gentisate stabilizer selected from gentisic acid and its soluble pharmaceutically-acceptable salts and esthers. (E.G.)

  15. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Tofe, A.J.

    1976-01-01

    A stable radiographic scanning agent on a sup(99m)Tc basis has been developed. The substance contains a pertechnetate reduction agent, tin(II)-chloride, chromium(II)-chloride, or iron(II)-sulphate, as well as an organospecific carrier and ascorbic acid or a pharmacologically admissible salt or ester of ascorbic acid. (VJ) [de

  16. Computed tomography for radiographers

    International Nuclear Information System (INIS)

    Brooker, M.J.

    1986-01-01

    This book is directed towards giving radiographers an introduction to and basic knowledge of computerized tomography. The technical section discusses gantries and x-ray production, computer and disc drive image display, storage, artefacts quality assurance and design of departments. The clinical section includes patient preparation, radiotherapy planning, and interpretation of images from various areas of the anatomy. (U.K.)

  17. Radiographic interpretation of the appendicular skeleton: A comparison between casualty officers, nurse practitioners and radiographers

    International Nuclear Information System (INIS)

    Coleman, Liz; Piper, Keith

    2009-01-01

    Aim: To assess how accurately and confidently casualty officers, nurse practitioners and radiographers, practicing within the emergency department (ED), recognize and describe radiographic trauma within an image test bank of 20 appendicular radiographs. Method: The participants consisted of 7 casualty officers, 13 nurse practitioners and 18 radiographers. All 20 radiographic examinations selected for the image test bank had been acquired following trauma and included some subtle, yet clinically significant abnormalities. The test bank score (maximum 40 marks), sensitivity and specificity percentages were calculated against an agreed radiological diagnosis (reference standard). Alternative Free-response Receiver Operating Characteristic (AFROC) analysis was used to assess the overall performance of the diagnostic accuracy of these professional groups. The variation in performance between each group was measured using the analysis of variance (ANOVA) test, to identify any statistical significant differences in the performance in interpretation between these groups. The relationship between the participants' perceived image interpretation accuracy during clinical practice and the actual accuracy of their image test bank score was examined using Pearson's Correlation Coefficient (r). Results: The results revealed that the radiographers gained the highest mean test bank score (28.5/40; 71%). This score was statistically higher than the mean test bank scores attained by the participating nurse practitioners (21/40; 53%) and casualty officers (21.5/40; 54%), with p < 0.01 and p = 0.02, respectively. When compared with each other, the scores from these latter groups showed no significant difference (p = 0.91). The mean 'area under the curve' (AUC) value achieved by the radiographers was also significantly higher (p < 0.01) in comparison to the AUC values demonstrated by the nurse practitioners and casualty officers, whose results, when compared, showed no significant

  18. Stenting or not prior to extracorporeal shockwave lithotripsy for ureteral stones? Results of a prospective randomized study.

    Science.gov (United States)

    Sfoungaristos, Stavros; Polimeros, Nikolaos; Kavouras, Adamantios; Perimenis, Petros

    2012-06-01

    To determine the need for pre-treatment stenting in patients undergoing extracorporeal shockwave lithotripsy (ESWL) for ureteral stones sized 4-10 mm. A prospective randomized study was conducted between September 2009 and March 2011. Included 156 patients randomized in stented and non-stented groups and underwent a maximum of 3 ESWL sessions. Radiographic follow-up was used to assess the stone fragmentation and clearance. Results were compared in terms of stone-free rates, post-treatment morbidity and complications. Overall efficacy was 76.9%. Stone-free rates were statistically significantly lower (P = 0.026) in the stented group (68.6%) compared to the non-stented ones (83.7%). Furthermore, stenting was significantly correlated with post-treatment lower urinary tract symptoms (P ≤ 0.001), need for more ESWL sessions (P = 0.019) and possibility for operation due to ESWL failure (P = 0.026). A multivariate analysis was conducted to identify the parameters which may predict complete stone removal after ESWL. Stone size (P = 0.026), stone location (P = 0.011) and stenting (P = 0.007) were the most significant factors. ESWL is an efficient and safe treatment for 4- to 10-mm ureteral stones. Pre-treatment stenting is limiting stone-free rates and is significantly influencing post-ESWL morbidity and quality of life in a negative manner, while it contributes minimally to the prophylaxis of complications.

  19. Efficacy of surgical techniques and factors affecting residual stone rate in the treatment of kidney stones.

    Science.gov (United States)

    Aydemir, Hüseyin; Budak, Salih; Kumsar, Şükrü; Köse, Osman; Sağlam, Hasan Salih; Adsan, Öztuğ

    2014-09-01

    In this study, we aimed to evaluate, the efficacy of surgical methods and the factors affecting the residual stone rate by scrutinizing retrospectively the patients who had undergone renal stone surgery. Records of 109 cases of kidney stones who had been surgically treated between January 2010, and July 2013 were reviewed. Patients were divided into three groups in terms of surgical treatment; open stone surgery, percutaneous nephrolithotomy (PNL) and retrograde intrarenal surgery (RIRS). Patients' history, physical examination, biochemical and radiological images and operative and postoperative data were recorded. The patients had undergone PNL (n=74; 67.9%), RIRS (n=22;20.2%), and open renal surgery (n=13; 11.9%). The mean and median ages of the patients were 46±9, 41 (21-75) and, 42 (23-67) years, respectively. The mean stone burden was 2.6±0.7 cm(2) in the PNL, 1.4±0.1 cm(2) in the RIRS, and 3.1±0.9 cm(2) in the open surgery groups. The mean operative times were 126±24 min in the PNL group, 72±12 min in the RIRS group and 82±22 min in the open surgery group. The duration of hospitalisation was 3.1±0.2 days, 1.2±0.3 days and 3.4±1.1 days respectively. While the RIRS group did not need blood transfusion, in the PNL group blood transfusions were given in the PNL (n=18), and open surgery (n=2) groups. Residual stones were detected in the PNL (n=22), open surgery (n=2), and RIRS (n=5) groups. PNL and RIRS have been seen as safe and effective methods in our self application too. However, it should not be forgotten that as a basical method, open surgery may be needed in cases of necessity.

  20. Optimizing radiation exposure for CT localizer radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Bohrer, Evelyn; Maeder, Ulf; Fiebich, Martin [Univ. of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection-IMPS; Schaefer, Stefan; Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Noel, Peter B. [Technische Univ. Muenchen (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-08-01

    The trend towards submillisievert CT scans leads to a higher dose fraction of localizer radiographs in CT examinations. The already existing technical capabilities make dose optimization of localizer radiographs worthwhile. Modern CT scanners apply automatic exposure control (AEC) based on attenuation data in such a localizer. Therefore not only this aspect but also the detectability of anatomical landmarks in the localizer for the desired CT scan range adjustment needs to be considered. The effective dose of a head, chest, and abdomen-pelvis localizer radiograph with standard factory settings and user-optimized settings was determined using Monte Carlo simulations. CT examinations of an anthropomorphic phantom were performed using multiple sets of acquisition parameters for the localizer radiograph and the AEC for the subsequent helical CT scan. Anatomical landmarks were defined to assess the image quality of the localizer. CTDI{sub vol} and effective mAs per slice of the helical CT scan were recorded to examine the impact of localizer settings on a helical CT scan. The dose of the localizer radiograph could be decreased by more than 90% while the image quality remained sufficient when selecting the lowest available settings (80 kVp, 20 mA, pa tube position). The tube position during localizer acquisition had a greater impact on the AEC than the reduction of tube voltage and tube current. Except for the use of a pa tube position, all changes of acquisition parameters for the localizer resulted in a decreased total radiation exposure. A dose reduction of CT localizer radiograph is necessary and possible. In the examined CT system there was no negative impact on the modulated helical CT scan when the lowest tube voltage and tube current were used for the localizer.

  1. Commitment of the radiographer - does it matter to the patient?

    International Nuclear Information System (INIS)

    Blagoeva, D.; Shuleva, L.; Goudeva, V.; Stoinova, V.

    2015-01-01

    Full text: Radiographers are responsible for providing safe and accurate imaging examinations in a wide range of clinical environments, using a variety of imaging modalities and techniques so that appropriate management and treatment of patients and clients can proceed. The purpose of this presentation is to discuss: the responsibilities of radiographer in the clinical radiology department; their professional judgment to decide how to achieve a diagnostic outcome; the relationship patient/radiographer; the impact of the radiographer on patient care. Patient care and advocacy has always been an integral part of the radiography profession. The radiographer should respect the patient at all the times, be genuine in nature and empathies with the patient‘s condition. Good listening and observational skills are also very important components. The radiographers are personally accountable for their work and professional conduct

  2. Throwing behavior and mass distribution of stone selection in tufted capuchin monkeys (Cebus apella).

    Science.gov (United States)

    Cleveland, A; Rocca, A R; Wendt, E L; Westergaard, G C

    2003-12-01

    Cannell [Journal of Archaeological Science 29:335-339, 2002] argued that sex-based differences among humans in terms of the mass of chosen throwing stones could be used to infer body mass and patterns of sexual dimorphism in early hominids from Olduvai and Koobi Fora by examining the mass distributions of unaltered stone tools at those sites. We examined this hypothesis in tufted capuchin monkeys using a comparative approach, by investigating the relationships among body mass, sex, stone weight preference, and accuracy in a throwing task. The subject sample consisted of nine monkeys trained to perform an aimed-throwing task in which a food reward could be obtained by throwing a stone into a bucket. We found that 1) the subjects showed a strong mean stone mass preference; 2) the females chose heavier stones than the males, in terms of absolute mean selected stone mass and selected stone mass relative to body mass; 3) subjects threw more accurately when they used stones of preferred mass vs. stones of nonpreferred mass; and 4) overall, the males were more accurate in the throwing task than the females. We conclude that capuchins are highly selective when choosing throwing stones, and that this confers an advantage for throwing accuracy. Our results indicate that the sexually dimorphic pattern in stone mass preference observed among humans does not generalize to Cebus apella. We suggest that researchers examining this pattern in humans in an attempt to explain early hominid patterns of dimorphism and behavior should take into account not only stone weight preference, but also its adaptive advantage. Copyright 2003 Wiley-Liss, Inc.

  3. Effects of microgravity on renal stone risk assessment

    Science.gov (United States)

    Pietrzyk, R. A.; Pak, C. Y. C.; Cintron, N. M.; Whitson, P. A.

    1992-01-01

    Physiologic changes induced during human exposure to the microgravity environment of space may contribute to an increased potential for renal stone formation. Renal stone risk factors obtained 10 days before flight and immediately after return to earth indicated that calcium oxalate and uric acid stone-forming potential was increased after space flights of 4-10 days. These data describe the need for examining renal stone risk during in-flight phases of space missions. Because of limited availability of space and refrigerated storage on spacecraft, effective methods must be developed for collecting urine samples in-flight and for preserving (or storing) them at temperatures and under conditions commensurate with mission constraints.

  4. Bath Stone - a Possible Global Heritage Stone from England

    Science.gov (United States)

    Marker, Brian

    2014-05-01

    The Middle Jurassic strata of England have several horizons of oolitic and bioclastic limestones that provide high quality dimension stone. One of the most important is found in and near the City of Bath. The Great Oolite Group (Upper Bathonian) contains the Combe Down and Bath Oolites, consisting of current bedded oolites and shelly oolites, that have been used extensively as freestones for construction nearby, for prestigious buildings through much of southern England and more widely. The stone has been used to some extent since Roman times when the city, then known as Aquae Sulis, was an important hot spa. The stone was used to a limited extent through medieval times but from the early 18th century onwards was exploited on a large scale through surface quarrying and underground mining. The City was extensively redeveloped in the 18th to early 19th century, mostly using Bath Stone, when the spas made it a fashionable resort. Buildings from that period include architectural "gems" such as the Royal Crescent and Pulteney Bridge, as well as the renovated Roman Baths. Many buildings were designed by some of the foremost British architects of the time. The consistent use of this stone gives the City an architectural integrity throughout. These features led to the designation of the City as a World Heritage Site. It is a requirement in current City planning policy documents that Bath Stone should be used for new building to preserve the appearance of the City. More widely the stone was used in major houses (e.g. Buckingham Palace and Apsley House in London; King's Pavilion in Brighton); civic buildings (e.g. Bristol Guildhall; Dartmouth Naval College in Devon); churches and cathedrals (e.g. Truro Cathedral in Cornwall); and engineered structures (e.g. the large Dundas Aqueduct on the Kennet and Avon Canal). More widely, Bath Stone has been used in Union Station in Washington DC; Toronto Bible College and the Town Hall at Cape Town, South Africa. Extraction declined in

  5. [Solitary stones of the lower renal calyx: how to treat?

    Science.gov (United States)

    Martov, A G; Ergakov, D V; Andronov, A S; Dutov, S V; Takhaev, R A; Kil'chukov, Z I; Moskalenko, S A

    2017-06-01

    The choice of treatment for the stones of the lower renal calyx is one of the challenging issues of modern urology. The aim of this retrospective and prospective study was to investigate the clinical effectiveness and safety of 3 modern minimally invasive techniques for treating renal stones: percutaneous (PNL) and transurethral (TNL) nephrolithotripsy and extracorporeal shock wave lithotripsy (ESWL) in patients with solitary lower calyx stones sized from 10 to 15 mm. The study included 136 patients with symptomatic stones of the lower calyces, who underwent ESWL, PNL and TNL from November 2010 to the present day. The criteria for inclusion in the study were: the presence of a solitary stone of the lower calyx, the stone size of 10 mm to 15 mm, the performance of the classical (standard) PNL in the prone position (puncture access 28-30 Fr) and the follow-up examination at 3 months after the operation. Forty-six patients underwent ESWL, 49 - PNL, and 41 - TNL. Postoperative follow-up was done at 3 months and included a plain radiography, ultrasound and non-contrast-enhanced computed tomography. The stone free rate (SFR) was used as a criterion for the effectiveness of the intervention, where the stone size of 3 mm was taken as the upper limit for the possible presence of fragments. Besides, the rate of repeat interventions, complications and subjective assessment of patients treatment satisfaction (0 to 10) by using visual analogue scale (VAS) were investigated. The effectiveness analysis of the three methods for treating the lower calyx stones sized 10-15 mm showed that PNL was no more effective than TNL (SFR 95.9% and 85.4%, respectively), but both methods were significantly more effective than ESWL (SFR 69.5%). 29.3% of patients who underwent TNL required repeat interventions (TNL or ESWL), while among those treated with ESWL, 45.6% required repeat ESWL sessions. PNL resulted in stone clearance in one stage. Postoperative inflammatory complications were most

  6. Accurately Diagnosing Uric Acid Stones from Conventional Computerized Tomography Imaging: Development and Preliminary Assessment of a Pixel Mapping Software.

    Science.gov (United States)

    Ganesan, Vishnu; De, Shubha; Shkumat, Nicholas; Marchini, Giovanni; Monga, Manoj

    2018-02-01

    Preoperative determination of uric acid stones from computerized tomography imaging would be of tremendous clinical use. We sought to design a software algorithm that could apply data from noncontrast computerized tomography to predict the presence of uric acid stones. Patients with pure uric acid and calcium oxalate stones were identified from our stone registry. Only stones greater than 4 mm which were clearly traceable from initial computerized tomography to final composition were included in analysis. A semiautomated computer algorithm was used to process image data. Average and maximum HU, eccentricity (deviation from a circle) and kurtosis (peakedness vs flatness) were automatically generated. These parameters were examined in several mathematical models to predict the presence of uric acid stones. A total of 100 patients, of whom 52 had calcium oxalate and 48 had uric acid stones, were included in the final analysis. Uric acid stones were significantly larger (12.2 vs 9.0 mm, p = 0.03) but calcium oxalate stones had higher mean attenuation (457 vs 315 HU, p = 0.001) and maximum attenuation (918 vs 553 HU, p uric acid stones. A combination of stone size, attenuation intensity and attenuation pattern from conventional computerized tomography can distinguish uric acid stones from calcium oxalate stones with high sensitivity and specificity. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  7. Stone cladding engineering

    CERN Document Server

    Sousa Camposinhos, Rui de

    2014-01-01

    This volume presents new methodologies for the design of dimension stone based on the concepts of structural design while preserving the excellence of stonemasonry practice in façade engineering. Straightforward formulae are provided for computing action on cladding, with special emphasis on the effect of seismic forces, including an extensive general methodology applied to non-structural elements. Based on the Load and Resistance Factor Design Format (LRDF), minimum slab thickness formulae are presented that take into consideration stress concentrations analysis based on the Finite Element Method (FEM) for the most commonly used modern anchorage systems. Calculation examples allow designers to solve several anchorage engineering problems in a detailed and objective manner, underlining the key parameters. The design of the anchorage metal parts, either in stainless steel or aluminum, is also presented.

  8. Evaluation of panoramic radiographs taken from 1056 Turkish children

    African Journals Online (AJOL)

    Objective: Panoramic radiographs (PRs) play an important role in the diagnosis and treatment planning of a wide range of dental and maxillofacial diseases and conditions. To examine and to determine the status of oral lesions, dental anomalies and pathologies in panoramic radiographs, which were taken at the ...

  9. Radiographic progession of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Siozos, C.D.

    1981-01-01

    The radiographic progression of rheumatoid arthritis can be graded on a 0-IV scala. For this purpose five objective criteria are used: a) destruction, b) osteoporosis, c) narrowing of joint space, d) luxation and e) ankylosis. The grading of the radiographic progression is defined by the extent and the number of the measured alterations. The radiographic progression can be registered yearly. (orig.) [de

  10. The bioreceptivity of building stone

    Science.gov (United States)

    Mauko Pranjić, Alenka; Mulec, Janez; Muck, Tadeja; Hladnik, Aleš; Mladenovič, Ana

    2015-04-01

    Bioreceptivity is an intrinsic property of stone, and is defined as the ability of a material to be colonized by living organisms. The fouling and staining of building stone material due to the activity of microorganisms presents a serious problem in modern as well as historical buildings, not only due to the aesthetic impact but also due to the deterioration of the material. Biological colonisation on stone materials is influenced by a number of factors, e.g. the intrinsic properties of the stone (porosity, roughness, permeability, mineral composition), environmental parameters (e.g. solar radiation, temperature, water regime, climate, etc.), and specific microclimatic parameters (e.g. orientation, exposure to shadow, permanent capillary humidity, etc.). In order to assess the bioreceptivity of building stones, use is often made of artificial colonisation experiments compromising the inoculation of stones with a single species or a few isolated strains under laboratory conditions. In the present work the authors present the development of a method for the determination of bioreceptivity, as well as a study of the bioreceptivity of selected natural stone versus the latter's intrinsic properties. Field examples of biodeterioration are also presented. The study was supported by the Slovenian Research Agency (L1-5453).

  11. Correlation between visual and radiographic examinations of non-cavitated occlusal caries lesions: an in vivo study Correlação entre os exames visual e radiográfico de lesões de cárie oclusal não cavitadas: estudo in vivo

    Directory of Open Access Journals (Sweden)

    Victor Ferrás Wolwacz

    2004-06-01

    Full Text Available The aim of this study was to conduct an in vivo investigation of the correlation between the visual and radiographic scoring systems by Ekstrand et al.7 (1997 for the diagnosis of occlusal caries lesions. The study sample comprised 147 occlusal sites from 23 patients. Two trained and experienced examiners performed the clinical visual examinations. A third examiner, which was also trained, experienced and blind to the results of the visual clinical examination, performed the analysis of the bitewing radiographs. The correlation between visual and radiographic scores was assessed by Goodman & Kruskal's gamma correlation coefficient. Results showed a strong correlation between the scores for occlusal caries found in the visual and radiographic diagnosis systems used in this study.O presente estudo verificou in vivo a correlação existente entre os sistemas de escore visual e radiográfico de Ekstrand et al.7 (1997 para diagnóstico de lesões de cárie oclusal. A amostra do estudo foi constituída de 147 sítios oclusais obtidos a partir de 23 pacientes. Os exames clínicos visuais foram realizados por dois examinadores treinados e calibrados. A análise das radiografias interproximais foi realizada por um terceiro examinador também treinado e calibrado, que desconhecia os resultados do exame clínico visual. A correlação entre os escores visual e radiográfico foi avaliada por meio do coeficiente de correlação gamma de Goodman & Kruskal. Os resultados revelaram uma forte correlação existente entre os escores dos sistemas de diagnóstico visual e radiográfico de cárie oclusal adotados no presente estudo.

  12. Trends in urological stone disease.

    Science.gov (United States)

    Turney, Benjamin W; Reynard, John M; Noble, Jeremy G; Keoghane, Stephen R

    2012-04-01

    To summarize the changes in prevalence and treatment of upper urinary tract stone disease in the UK over the last 10 years. Data from the Hospital Episode Statistics (HES) website (http://www.hesonline.nhs.uk) were extracted, summarized and presented. The number of upper urinary tract stone hospital episodes increased by 63% to 83,050 in the 10-year period. The use of shock wave lithotripsy (SWL) for treating all upper tract stones increased from 14,491 cases in 2000-2001 to 22,402 cases in 2010 (a 55% increase) with a 69% increase in lithotripsy for renal stones. There was a 127% increase in the number of ureteroscopic stone treatments from 6,283 to 14,242 cases over the 10-year period with a 49% increase from 2007/2008 to 2009/2010. There was a decline in open surgery for upper tract stones from 278 cases in 2000/2001 to 47 cases in 2009/2010 (an 83% reduction). Treatment for stone disease has increased substantially in comparison with other urological activity. In 2009/2010, SWL was performed almost as frequently as transurethral resection of the prostate or transurethral resection of bladder tumour, ureteroscopy for stones was performed more frequently than nephrectomy, radical prostatectomy and cystectomy combined, and percutaneous nephrolithotomy was performed more frequently than cystectomy. The present study highlights the increase in prevalence and treatment of stone disease in the UK over the last 10 years. If this trend continues it has important implications for workforce planning, training, service delivery and research in the field of urolithiasis. © 2011 THE AUTHORS. BJU INTERNATIONAL © 2011 BJU INTERNATIONAL.

  13. The radiographic investigation of two Egyptian mummies.

    Science.gov (United States)

    Fodor, J; Malott, J C; King, A Y

    1983-01-01

    Radiography is a well-recognized method of nondestructive analysis of art objects and ancient relics. The methods and techniques used in the examination of two ancient Egyptian mummies are presented here. Additionally, the use of radiographic findings to help substantiate alleged historical information and to establish sex, age, and pathology of each specimen is discussed.

  14. Radiographic techniques for digital mammography

    International Nuclear Information System (INIS)

    Horita, Katsuhei

    2007-01-01

    Since the differences in X-ray absorption between various breast tissues are small, a dedicated X-ray system for examination of the breast and a high-contrast, high-resolution screen/film system (SFM) (light-receiving system) are employed for X-ray diagnosis. Currently, however, there is a strong trend toward digital imaging in the field of general radiography, and this trend is also reflected in the field of mammographic examination. In fact, approximately 70% of facilities purchasing new mammography systems are now selecting a digital mammography system (DRM). Given this situation, this report reviews the differences between SFM and DRM and discusses the radiographic techniques and quality assurance procedures for digital mammography. (author)

  15. The study on the factors for detection of renal stone on ultrasound

    International Nuclear Information System (INIS)

    Sim, Hyun Sun; Jung, Hong Ryang; Lim, Cheong Hwan

    2006-01-01

    Renal stones are common and typically arise within the collecting system. The renal sinus are contains the collection system, the renal vessels, lymphatcs, fat, and fibrous tissue. Because of the compression of all the large echoes in signal processing, the echo from the renal stone generally cannot be distinguished from large echoes emanating from normal structures of the renal sinus. Use of ultrasonography has been difficult for detecting small renal stone without posterior shadowing and chemical composition of stone. The aim of study was measuring for posterior acoustic shadowing to a stone for various scan parameter and it examines a help in renal stone diagnosis. The stone was place on sponge examined in a water bath with a 3.5 MHz or 7.5 HMz transducer (LOGIQ 400, USA). First, tested a variety of gain. Second, tested a variety of dynamic range. Third, tested a variety of focal zone. Fourth, measuring of the echo level for low and high frequency for depth. 1) Average echo level was 98 for low total gain (10 dB) and was 142 for high total gain (40 dB). Posterior acoustic shadowing of renal stone was clear for low gain. 2) Average echo level was 129 for low dynamic range (42 dB) and was 101 for high dynamic range (72 dB). Posterior acoustic shadowing of renal stone was clear for high dynamic range. 3) When stone is in focal zone of transducer, definite posterior acoustic shadow is identified. 4) Stone was clear appeared for high frequency (7.5 MHz) than low frequency (3.5 MHz) and it is not distorted. The demonstration of an posterior acoustic shadow of renal stone dependents on several technical factors such as gain, dynamic range, focus, and frequency. This various factors are a help in renal stone diagnosis

  16. Radiographic study on temporomandibular joint Arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Dong Soo [Dept. of Radiology, College of Dentistry, Seoul National University , Seoul (Korea, Republic of)

    1980-11-15

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  17. Radiographic study on temporomandibular joint Arthrosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo

    1980-01-01

    The author analysed the routine radiographic changes and clinical symptoms of 205 cases of temporomandibular joint arthrosis. The clinical symptoms of the patients were classified and the morphological changes of condylar head, articular eminence, and articular fossa were analyzed and discussed from radiographic view point. The positional change of condylar head and articular fossa relation in TMJ arthrosis were observed. The frequencies of coincidence between the site of complaints and the site of the abnormal images which could be detected were examined. The results were obtained as follows; 1. Bone erosion, deformity, marginal proliferation and sclerosis were selected from many abnormal images as the radiographic diagnostic criteria of TMJ arthritic lesions. 2. Abnormal radiographic findings were revealed in 150 cases (73.9%) of 205 total TMJ arthrosis cases and site with abnormal findings coincided with the site of complaints in 105 cases (70.7%) of 150 cases and coincidence rates were higher above fourth decades than below third decades. 3. Sclerosis of the abnormal radiographic findings could be found more often below third decades than above fourth decades. 4. The positional changes of condylar head were revealed in 176 cases (85.9%) of 205 total cases. 5. Pain complaints were revealed in 170 cases(82.9%) and clicking sounds were revealed in 120 cases (58.6%) of clinical symptoms of TMJ arthrosis. 6. No tendency was found so far the differential diagnosis between pain dysfunction syndrome and osteoarthrosis of TMJ.

  18. Radiographic evaluation of the diabetic foot

    International Nuclear Information System (INIS)

    Jacobs, A.M.

    1989-01-01

    Radiographic evaluation of the foot in the patient with diabetes mellitus is discussed in this paper. According to the author, it can only be of value when the soft tissue and bony and joint pathologic conditions, which occur more frequently in the diabetic patient are also considered and understood. Although not pathognomic for diabetes mellitus, neuroarthopathy, osteomyelitis, soft tissue infection, and some rheumatic disorders are present with greater frequency in diabetic populations than in non-diabetic populations. Frequently, edema, erythema, hyperthermia, and tenderness are present as nonspecific clinical findings, in which case radiographic evaluation is called upon to define the specific etiology of a particular patient's pathology. Unfortunately, many radiographic, computerized tomographic, and radionuclide studies demonstrate less than optimal positive and negative predictive values unless interpreted in view of clinical history and examination and integrated with the results of other laboratory data. Radiographic evaluation of the diabetic foot may be utilized to establish the presence of disease, the extent of pedal involvement, and the response to therapy. The establishment of the nature of disease processes from radiographic findings alone, however, may be problematic. The diagnosis of osteomyelitis, for example, rests on the recovery of the offending microorganisms from bone aspiration or culture

  19. ORIGINAL PAPER ORIG ORIG Percutaneous stone removal

    African Journals Online (AJOL)

    Percutaneous nephrolithotomy (PCNL) is an effective procedure to treat patients with complex renal stones,. e.g. staghorn calculi and stones greater than 20 mm in diameter. The treatment of choice for small, less com- plex renal stones is extracorporeal shock-wave litho- tripsy (ESWL).1 We have treated renal stones mainly.

  20. Modeling dental radiographic systems

    International Nuclear Information System (INIS)

    Webber, R.L.

    1980-01-01

    The Bureau of Radiological Health has been actively collaborating with the Clinical Investigations Branch, NIDR, in applied research involving diagnostic use of ionizing radiation in dentistry. This work has centered on the search for alternatives to conventional radiographic systems in an attempt to improve diagnostic performance while reducing the required exposure. The basic approach involves analysis of factors limiting performance of properly defined diagnostic tasks and the modeling alternative systems with an eye toward increasing objective measures of performance. Previous collaborative work involved using a nonlinear model to compare various x-ray spectra. The data were expressed as brightness-contrast versus exposure for simulated tasks of clinical interest. This report supplements these findings by extending the number of parameters under investigation and modifying the mode of data display so that an actual radiographic image can be simulated on a television screen

  1. Technique and value of three dimensional reconstruction of stones in the renal pelvis using spiral CT

    International Nuclear Information System (INIS)

    Fink, B.K.; Fink, U.; Pentenrieder, M.; Kohz, P.; Englmeier, H.K.; Schmeller, N.

    1994-01-01

    5 patients with staghorn calculi in the renal pelvis were examined by spiral CT. From the raw data three dimensional reconstructions of the stones were obtained. In all patients it was possible to compare the three dimensional model with the stone following performance of percutaneous lithopaxy and endoscopic removal of the fragments. In all cases the three dimensional reconstruction provided a realistic image of the stones and was of practical value for the urologist for preoperative diagnosis and intraoperative control. (orig.) [de

  2. Quality Assessment of Urinary Stone Analysis

    DEFF Research Database (Denmark)

    Siener, Roswitha; Buchholz, Noor; Daudon, Michel

    2016-01-01

    After stone removal, accurate analysis of urinary stone composition is the most crucial laboratory diagnostic procedure for the treatment and recurrence prevention in the stone-forming patient. The most common techniques for routine analysis of stones are infrared spectroscopy, X-ray diffraction......, fulfilled the quality requirements. According to the current standard, chemical analysis is considered to be insufficient for stone analysis, whereas infrared spectroscopy or X-ray diffraction is mandatory. However, the poor results of infrared spectroscopy highlight the importance of equipment, reference...... spectra and qualification of the staff for an accurate analysis of stone composition. Regular quality control is essential in carrying out routine stone analysis....

  3. Radiographic findings in immunodeficiency

    International Nuclear Information System (INIS)

    Obregon, R.; Lynch, D.A.; Cink, T.M.; Newell, J.D.; Kirkpatrick, C.

    1991-01-01

    This paper reviews the chest radiographs and high-resolution CT (HRCT) scans in patients with immunodeficiency disorders and define the role of HRCT. Thirty-three cases were retrospectively graded according to the consensus of two radiologists. Patients with HIV seropositivity and asthma were excluded. HRCT was performed in 12 cases with standard techniques. Diagnoses included common variable hypogammaglobulinemia (n = 19), X-linked agammaglobulinemia (n = 4), chronic mucocutaneous candidiasis (n = 4), and selective immunoglobulin g deficiencies (n = 2). Chest radiographs showed bronchiectasis in 11 of 33 cases with a predominant lower lobe distribution (82%). Nodules were present in six cases and mucus plugs in four cases. HRCT showed bronchiectasis in nine of 12 cases; in five of these nine cases, bronchiectasis was not apparent on chest radiographs. Other HRCT findings included segmental air trapping (four of 12), mucus plugs (three of 12), hazy consolidation (four of 12), nodules (five of 12), and bronchiolectasis (two of 12). Therapy was altered in seven of 12 cases in which HRCT was performed. Most pertinent to clinical management were the presence of a thymoma (n = 1) and severe focal of diffuse bronchiectasis

  4. Radiographic testing of wood

    International Nuclear Information System (INIS)

    Osterloh, K.; Zscherpel, U.; Raedel, C.; Weidemann, G.; Meinel, D.; Goebbels, J.; Ewert, U.; Hasenstab, A.; Buecherl, T.

    2007-01-01

    Wood is an old and established consumption and construction material. It is still the most common material for constructing furniture, roofs, playgrounds and mine supports. In contrast to steel and concrete, wood warns of extreme loads by creaking. Its mechanical stability is more influenced by decay than by peripheral cracks. While external cracks are visible, internal decay by fungus growth is undetectable from outside. This may be a safety problem in supporting structures. The best analysis of the internal structure is provided by computed tomography, but this is also the most complex method, much more so than simple radiographic testing. However, the latter is made inaccurate by scattered radiation resulting from internal moisture. With the image processing options of digital radiographic techniques, the structural information can be separated effectively from noise. In contrast to X-ray and gamma radiography, neutron radiography provides information on the spatial distribution of moisture. In healthy wood, water is conducted in the sapwood while the hardwood is dry. Moisture in hardwood is caused by infestations, e.g. fungus growth. The contribution presents a comparative analysis of the available radiographic methods. (orig.)

  5. Radiograph identifying means

    International Nuclear Information System (INIS)

    Sheldon, A.D.

    1983-01-01

    A flexible character-indentable plastics embossing tape is backed by and bonded to a lead strip, not more than 0.025 inches thick, to form a tape suitable for identifying radiographs. The lead strip is itself backed by a relatively thin and flimsy plastics or fabric strip which, when removed, allows the lead plastic tape to be pressure-bonded to the surface to be radiographed. A conventional tape-embossing gun is used to indent the desired characters in succession into the lead-backed tape, without necessarily severing the lead; and then the backing strip is peeled away to expose the layer of adhesive which pressure-bonds the indented tape to the object to be radiographed. X-rays incident on the embossed tape will cause the raised characters to show up dark on the subsequently-developed film, whilst the raised side areas will show up white. Each character will thus stand out on the developed film. (author)

  6. Radiographic and tomographic study of the elbow joint in dogs

    International Nuclear Information System (INIS)

    Sendyk-Grunkraut, Alessandra; Martin, Claudia M.; Souza, Alexandre N.A.; Patricio, Geni Cristina F.; Lorigados, Carla A.B.; Matera, Julia M.; Fonseca-Pinto, Ana C.B.C.

    2017-01-01

    Elbow dysplasia disease includes an united anconeal process, fragmented medial coronoid process, osteochondrosis of humeral trochlea, articular incongruity and degenerative joint disease. The aim of this study was to present detailed morphologic and morphometric aspects of the elbow joint in dog in clinical and correlate with radiographic and tomographic (CT) exam. Inter-observer variation for articular incongruity measurements by CT, comparative analysis in the radiographic exam, angle in ulnar notch and its comparative analysis between radiographic and tomographic agreement examination in 44 elbow of dogs with different ages were evaluated. The statistics analyses included the kappa coefficient and interclass correlation and Fischer's test and McNemar's test. It was evidenced that individual performance of each radiographic incidence had poor agreement with the tomographic exam, suggesting that the accomplishment of more than two radiograph views are needed. There was no agreement between the three evaluators in the ulnar notch angle at radiographic and tomographic exams. However, there was good/moderate agreement for articular incongruity measurement in the sagittal plane between evaluators. It was possible to conclude that none of the five radiographic incidences was better than the others for radiographic analysis because each incidence had a better identification of a particular elbow compartment; measurements at the tomographic exam to evaluate radioulnar incongruity had no reproductiveness in the frontal plane, but in sagittal plan had a good/moderate agreement between observers and the angle in ulnar notch presented no repeatability at radiographic exam and no reproductiveness at tomographic exam. (author)

  7. The Stones and the Stars Building Scotland's Newest Megalith

    CERN Document Server

    Lunan, Duncan

    2013-01-01

    There are at least 48 identified prehistoric stone circles in Scotland.  In truth, very little is known about the people who erected them, and ultimately about what the stone circles were for.  Most stone circles are astronomically aligned, which has led to the modern debate over the significance of the alignments.  The megaliths certainly represented an enormous cooperative effort, would at the very least have demonstrated power and wealth, and being set away from any dwellings probably served a ceremonial, or perhaps religious, purpose. Observations at the site of the stone circles, of solar, lunar, and stellar events, have already cast light on some of the questions about the construction and use of ancient megalithic observatories. In his capacity as manager of the Glasgow Parks Department Astronomy Project, author Duncan Lunan designed and built in the late 1970s Sighthill, the first astronomically aligned stone circle in Britain in over 3,000 years.  The Stones and the Stars examines the case for as...

  8. Histopathology Predicts the Mechanism of Stone Formation

    Science.gov (United States)

    Evan, Andrew P.

    2007-04-01

    About 5% of American women and 12% of men will develop a kidney stone at some time in their life and these numbers appear to be on the rise. Despite years of scientific research into the mechanisms of stone formation and growth, limited advances have been made until recently. Randall's original observations and thoughts on the mechanisms for kidney stone formation have been validated for idiopathic calcium oxalate stone formers (ICSF) but not for most other stone forming groups. Our current studies on selected groups of human stone formers using intraoperative papillary biopsies has shown overwhelming evidence for the presence of Randall's plaque in ICSF and that stone formation and growth are exclusively linked to its availability to urinary ions and proteins. Intense investigation of the plaque-stone junction is needed if we are to understand the factors leading to the overgrowth process on exposed regions of plaque. Such information should allow the development of treatment strategies to block stone formation in ICSF patients. Patients who form brushite stones, or who form apatite stones because of distal renal tubular acidosis (dRTA), or patients with calcium oxalate stones due to obesity bypass procedures, or patients with cystinuria, get plugged inner medullary collecting ducts (IMCD) which leads to total destruction of the lining cells and focal sites of interstitial fibrosis. These stone formers have plaque but at levels equal to or below non-stone formers, which would suggest that they form stones by a different mechanism than do ICSF patients.

  9. Shielding features of quarry stone

    International Nuclear Information System (INIS)

    Hernandez V, C.; Contreras S, H.; Hernandez A, L.; Baltazar R, A.; Escareno J, E.; Mares E, C. A.; Vega C, H. R.

    2010-10-01

    Quarry stone lineal attenuation coefficient for gamma-rays has been obtained. In Zacatecas, quarry stone is widely utilized as a decorative item in buildings, however its shielding features against gamma-rays unknown. The aim of this work is to determine the shielding properties of quarry stone against γ-rays using Monte Carlo calculations where a detailed model of a good geometry experimental setup was carried out. In the calculations 10 pieces 10 X 10 cm 2 of different thickness were utilized to evaluate the photons transmission as the quarry stone thickness is increased. It was noticed that transmitted photons decay away as the shield thickness is increased, these results were fitted to an exponential function were the linear attenuation coefficient was estimated. Also, using XCOM code the linear attenuation coefficient from several keV up to 100 MeV was estimated. From the comparison between Monte Carlo results and XCOM calculations a good agreement was found. For 0.662 MeV γ-rays the attenuation coefficient of quarry stone, whose density is 2.413 g-cm -3 , is 0.1798 cm -1 , this mean a X 1/2 = 3.9 cm, X 1/4 = 7.7 cm, X 1/10 = 12.8 cm, and X 1/100 = 25.6 cm. Having the information of quarry stone performance as shielding give the chance to use this material to shield X and γ-ray facilities. (Author)

  10. Kidney Stones and Ceftriaxone

    Directory of Open Access Journals (Sweden)

    Murat Dursun

    2015-01-01

    Full Text Available Metabolic causes such as hypercalciuria, urinary tract infection, and obstruction are the most common aetiologies of urolithiasis, and drugs, although important in this regard, are rarely the cause of urolithiasis. Administration of one of these drugs, ceftriaxone (CTX, has been associated with biliary pseudolithiasis in adult and paediatric patients, and rarely may cause urolithiasis. Several factors, including drug concentration and incubation time, are very important for determining the degree of CTX/calcium (Ca crystallisation in the urine. According to this data, CTX crystallisation was a dose and time-dependent reaction. It is particularly important to monitor patients on high-dose long-term CTX treatment with the urinary Ca to creatinine ratios, ultrasound sonography, and renal function testing, as these individuals may be at greater risk of large stones and renal damage. This type of screening may help prevent permanent complications in the future. This underlying review will help to educate readers on the pathophysiology and interaction between CTX and urolithiasis.

  11. Unusual radiographic changes of a gout patient

    International Nuclear Information System (INIS)

    Markota, J.

    2004-01-01

    Background. Gout is a metabolic disorder that results in hyperuricemia and accumulation of uric acid crystals (urats) in tissues, especially joint cartilage. The gouty arthritis presents as acute attacks of arthritis leading eventually to chronic gouty arthritis. In 80% of cases it first occurs in the matatarsophalangeal (MTP) joint of the great toe and is more frequent in male population. Case report. We present a case of unusual radiographic changes accompanying gouty arthritis. A 63 year old female complained about swelling of the first MTP joint on the right, right knee, about stiffness of feet and hands' digits and about backache. First symptoms started to appear 30 years ago. In the time of examination radiographs displayed degenerative changes of the majority of presented joints, bilateral sacroiliitis and osseous ankylosis of both insteps. Microscopic examination showed urate crystals in the samples of the synovial fluid aspirated from the knee. The histological findings of the synovial tissue after the synovectomy were also in favour of gouty arthritis. Conclusions. Radiographs are the most important imaging modality in the diagnostic process of gout. However, radiographic differential diagnosis can be difficult, since the findings overlap with other conditions which cause arthritis and osteoarthritis especially in longstanding gout, elderly patients and females. The diagnosis must be often confirmed with the help of laboratory and histological findings. (author)

  12. Purbeck Stone - A possible Global Heritage Stone from England

    Science.gov (United States)

    Marker, Brian

    2014-05-01

    By definition, a Global Heritage Stone Resource (GHSR) should have international significance. The Purbeck Group of uppermost Jurassic to lowermost Cretaceous age (Tithonian- Berriasian) outcrops mainly in the Purbeck area of Dorset, England. It was deposited in shallow freshwater to brackish lagoons with occasional marine incursions. Limestones, mainly biosparites, occur at 6 main levels. Differences in bed thickness, jointing and hardness make it suitable for a variety of purposes including dimension stone, monumental and ornamental stone, roofing tiles, paving, flooring and rockery stone. Near the top of the sequence is a dark gastropod biosparite, traditionally called Purbeck Marble, easily carved, which has been extensively used for decorative interior work in churches and cathedrals particularly for fonts, tombs, flooring and facings on columns for example in the medieval cathedrals of Salisbury, Exeter, Durham, York and Wells and Worcester and Westminster Abbey. The stone was extracted at least from Roman times (1st century AD) through the medieval period. Quarrying expanded from about 1700 reaching a peak in the late 18th and 19th centuries. Stone was transported first by sea but later by rail for wider use. Used in many local buildings, it gives an important element of local character. Many of the villages are designated conservation areas with a requirement for repair, maintenance and new building using local stone. Initially the stone was taken from quarries but was later mined. The number of operating companies declined from 15 to 5 over the past 40 years, with 10 active small quarries. Outputs are from few hundred tonnes to a few thousand tonnes per annum or about 9 to 12 years of permitted reserves but the Planning Authority intends to make sufficient provision for production at recent levels for their development plan period. The extraction sites are in an Area of Outstanding Natural Beauty and close to Jurassic Coast World Heritage Site. This might

  13. [Gallbladder Stone Types in Patients with Cholelithiasis and Clonorchis sinensis Infection in the Endemic Area of Clonorchiasis].

    Science.gov (United States)

    Ma, Rui-hong; Qiao, Tie; Luo, Zhen-liang; Luo, Xiao-bing; Zheng, Pei-ming; Yang, Liu-qing

    2015-06-01

    To investigate the relationship between Clonorchis sinensis infection and the gallbladder stone type in patients with cholelithiasis in the endemic area of clonorchiasis. Gallbladder stones were collected from 598 patients with cholelithiasis through minimally invasive gallbladder-preserving cholelithotomy in the Sixth People's Hospital of Nansha District from May 2009 to October 2012. The stone samples were analyzed for composition by Fourier transform infrared spectroscopy to identify their types. The Clonorchis sinensis eggs were detected in the stones by microscopic examination, and the detection rates of eggs were calculated for different stone types. Then the clinical characteristics and biochemical indicators were compared among patients with different types of stones, as well as between Clonorchis sinensis egg-positive and -negative patients with the calcium-carbonate type of stones. Some calcium-carbonate stones positive for Clonorchis sinensis eggs were randomly selected for further scanning electron microscopy (SEM) examination. Of the stones from 598 patients, 234 (39.1%) were cholesterol type, 133 (22.2%) bile pigment type, 112(18.7%) calcium-carbonate type, 86 (14.4%) mixed types and 33(5.5%) were others. The detection rate of Clonorchis sinensis eggs in these types was 6% (15/234), 44% (59/133), 60% (67/112), 36% (31/ 86) and 30% (10/33), respectively, being highest in calcium-carbonate stones while lowest in cholesterol stones. The Co2-combining power of the plasma was higher in patients with calcium-carbonate and mixed stones than in those with cholesterol stones (P Clonorchis sinensis eggs to calcium-carbonate crystals. The infection rate of Clonorchis sinensis is higher in patients with calcium-carbonate gallbladder stones than in those with other types of stones.

  14. Radiographic evaluation of osteosynthesis

    International Nuclear Information System (INIS)

    Mueller-Miny, H.; Erlemann, R.; Roos, N.; Peters, P.E.; Baranowski, D.

    1991-01-01

    Surgeons, orthopedic surgeons, and neurosurgeons employ a wide variety of different osteosynthetic devices in the treatment of fractures and in spinal surgery. In order to assess these instruments correctly, the radiologist should be aware of their purpose and normal apperance. The complications should be identified, such as delayed union, pseudarthrosis, dislocation, device loosening, fracture of the device, osteomyelitis, and refracture. To evaluate the fixation device adequately two plain radiographs are mandatory. An normal fracture healing and the most commonly used fixation devices, the abnormalities of fracture healing and their complications are discussed. (orig.) [de

  15. Radiographic film digitizing devices

    International Nuclear Information System (INIS)

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  16. The effectiveness of ESWL in the management of lower pole kidney stones

    Directory of Open Access Journals (Sweden)

    Tufan Süelözgen

    2015-03-01

    Full Text Available Objective: The developments in the endourological treatments of urinary system stone diseases led to the discussions about the first choice treatment methods. We have evaluated the results of extracorporeal shock wave treatments being applied in our clinics for the lower pole stones which has the most of the those discussions. Methods: The records of 271 stone patients who were applied ESWL according to CT results between January 2013 and July 2013 to our clinics were examined. In the controls after the procedure, who could not be evaluated with the non-contrast computerized tomography (CT and ESWL treatment not completed, were excluded from the study. 52 patients with lower pole stone in total were divided into two according to the success of the ESWL treatment. ESWL success or unsuccessful groups, the size of the stone, density of the stone and the distance between the stone and skin was recorded by examining the abdominal non-contrast computed tomography (CT of the patient. Results: Of all, 28 of the patients in the study (54% were male and 24 of them (46% were female. The average age was 46±12.3 (21-73 years. Among the 52 patients included in the study after ESWL treatment, the stones of the 24 patients (46.2% were successfully treated. ESWL treatment was unsuccessful in total 28 patients (53.8%. The average size of the stone was 9.8 mm (6-17 mm, the distance between the stone and the skin was 93 mm in average (50-140. The stone density was measured as 845 HU (353-1600. Conclusion: The ESWL treatment is still a noninvasive and successful method for the lower pole kidney stones. While the ESWL success is being determined, the imaging method chosen is important, the use of abdominal CT provides accurate evaluation. The higher success rates of minimal invasive surgery methods is promising and might change the treatment methods in the future.

  17. Glass Foreign Body Hand Radiograph

    Directory of Open Access Journals (Sweden)

    Hamid Ehsani-Nia, DO

    2018-04-01

    Full Text Available History of present illness: A 27-year-old female sustained an injury to her left hand after she tripped and fell on a vase. She presented to the emergency department (ED complaining of pain over the laceration. Upon examination, patient presented with multiple small abrasions of the medial aspect of the left 5thdigit that are minimally tender. Additionally, she has one 0.5cm linear laceration of the medial aspect of the 5thmetacarpal with severe tenderness in the area and palpable underlying foreign body. Significant findings: Left hand plain radiography demonstrated a subcutaneous foreign body medial to the 5thmetacarpal that is radiopaque, trapezoidal in shape, and measures approximately 11mm x 3mm. Discussion: Laceration repairs are amongst the most common procedures in the emergency department; however, consideration for foreign body is often underdiagnosed. Imaging is performed in only about 11% of all traumatic wounds in the ED.1 Of those injuries relating to the hand that are subsequently imaged, about 15% are found to have a foreign body.2,3 Additionally, it is estimated that foreign bodies are present in 7% to 8.7% of all wounds caused by glass objects.4,5 Glass is among the most common foreign bodies in lacerations, and fortunately they are radiopaque and relatively well visualized radiographically. It has been demonstrated that 2mm glass foreign bodies have a 99% detection rate with radiography, and 1mm glass foreign bodies an 83% detection rate.6 Patient perception of foreign body has a positive predictive value of 31%, making it a poor source in influencing clinical decision-making to obtain wound radiographs.3 Clinicians should have a high suspicion for foreign body in lacerations, particularly those caused by glass, and utilize close physical examination and imaging for evaluation. Topics: Radiography, glass, foreign body, trauma

  18. Regional differences in constituents of gall stones.

    Science.gov (United States)

    Ashok, M; Nageshwar Reddy, D; Jayanthi, V; Kalkura, S N; Vijayan, V; Gokulakrishnan, S; Nair, K G M

    2005-01-01

    The pathogenesis of pigment and mixed gall stone formation remains elusive. The elemental constituents of gall stones from southern states of Tamil Nadu, Kerala and Karnataka have been characterized. Our aim was to determine the elemental concentration of representative samples of pigment, mixed and cholesterol gall stones from Andhra Pradesh using proton-induced X-ray emission (PIXE) using a 3 MV horizontal pelletron accelerator. Pigment gall stones had significantly high concentrations of copper, iron and lead; chromium was absent. Except for iron all these elements were significantly low in cholesterol gall stones and intermediate levels were seen in mixed gall stones. Highest concentrations of chromium was seen in cholesterol and titanium in mixed gall stones respectively; latter similar to other southern states. Arsenic was distinctly absent in cholesterol and mixed gall stones. The study has identified differences in elemental components of the gall stones from Andhra Pradesh.

  19. Comparison of radiographic and radionuclide skeletal surveys in battered children

    International Nuclear Information System (INIS)

    Pickett, W.J.; Faleski, E.J.; Chacko, A.; Jarrett, R.V.

    1983-01-01

    A review of 13 cases of suspected child abuse in which radionuclide (RN) scans, radiographic skeletal surveys, and sufficient follow-up were available showed that the RN scans were insensitive, even though fractures were more than 48 hours old at the time of the scan. Frequently missed lesions included skull and extremity fractures. Furthermore, soft tissue and visceral abnormalities that were identified on radiographic examination went undetected on RN scan. We conclude that, although the RN scan may augment the radiographic examination, it should not be used alone to screen for the battered child

  20. Interpreting radiographs. 4. The carpus

    International Nuclear Information System (INIS)

    Burguez, P.N.

    1984-01-01

    The complexity of the carpus which has three major joints, seven or eight carpal bones and five adjacent bones, each of which articulates with one or more of the carpal elements, necessitates good quality radiographs for definitive radiographic interpretation may be extremely difficult because of the disparity between radiographic changes and obvious clinical signs and, therefore, must be discussed in the light of a thorough clinical assessment

  1. Evaluation of the improvement of the double-contrast radiographic image quality in the prone position brought about by the use of a decision tree in the screening examination

    International Nuclear Information System (INIS)

    Yamada, Yasuji; Nakamura, Syunichi; Ohno, Ryuichi; Azuma, Hiroshi; Fujinaga, Akira; Nagai, Makoto

    2009-01-01

    We designed a decision tree in order to improve the double-contrast radiographic image quality in the prone position and compensate for the disparity of technique among radiological technologists. We evaluated 391 consecutive individuals who underwent medical checkups at our hospital. Three decision trees, id est (i.e.), Tree 1, Tree 2 and Tree 3, were constructed based on the axis and contortion of the stomach with the use of a prone filling image, and then the insertion site of compression pillow was altered. The image quality at the gastric angulus, the gastric body and the antrum was evaluated based on our original numeric scale, and was compared between the previous method and the present method which employs a decision tree. The image quality improved more significantly in the present method employing a decision tree compared with the previous method, for each decision tree: from 90 points to 100 points for Tree 1, from 70 points to 95 points for Tree 2, and from 39.5 points for 85.7 points in Tree 3. These results indicate that our original procedure employing a decision tree improves the radiographic image quality in the prone position and compensates for the disparity of technique among radiological technologists. Therefore, the present method may be expected to serve as the standard procedure of double-contrast radiography in the prone position. (author)

  2. The radiographic findings of adult congenital megacolon disease

    International Nuclear Information System (INIS)

    Deng Xiaotao; Yu Jingying; Zhang Yongchun

    2000-01-01

    Objective: To describe the radiographic findings of adult megacolon. Methods: Barium enema examination was performed in 6 patients with megacolon proved by operation. Results: The principal radiographic findings were a markedly dilated colon, the largest diameter was 22 cm, and a narrowed rectum, its length was 3-7 cm; with a cone or funnel shaped transitional segment, it is about 2-6 cm long. Conclusion: The barium enema examination is the most reliable and simple method in diagnosing adult congenital megacolon

  3. The interest of radiographical investigations of bone diseases in the selection of stallions [orthopedic lesions, abnormal radiographic findings, multivariate analysis

    International Nuclear Information System (INIS)

    Valette, J.P.; Touzot, G.; Denoix, J.M.

    1997-01-01

    Breeding of sport horses requires products with qualities for performance traits. The objectives of this study were to investigate the relation between radiographical examination and descendant of sires. Foots, fetlocks of both thoracic and pelvic limbs, carpus, tarsus and stifles were examined radiographically in 225 3-year old horses descent from 25 stallions. Data were analysed by multivariate analysis. Results indicate that descendant of a stallion presents the same abnormal radiographic findings. It is concluded that bone diseases are of great importance in breeding sport horses and that these abnormalities could have a genetic component [fr

  4. Stone clearance after extracorporeal shockwave lithotripsy in patients with solitary pure calcium oxalate stones smaller than 1.0 cm in the proximal ureter, with special reference to monohydrate and dihydrate content.

    Science.gov (United States)

    Ichiyanagi, Osamu; Nagaoka, Akira; Izumi, Takuji; Kawamura, Yuko; Tsukigi, Masaaki; Ishii, Tatsuya; Ohji, Hiroshi; Kato, Tomoyuki; Tomita, Yoshihiko

    2013-04-01

    The aim of this study was to assess stone-free rates following extracorporeal shockwave lithotripsy (ESWL) of pure calcium oxalate (CaOx) stones in the proximal ureter. The investigators retrospectively examined 53 patients with 5-10 mm pure CaOx stones in the proximal ureter from the medical archives of 593 consecutive patients treated with ESWL. The compositions of calcium oxalate monohydrate (COM) and dihydrate (COD) in a given stone were determined by infrared spectrometry. Stone size, attenuation number and stone-to-skin distance (SSD) were measured using plain radiography and computed tomography (CT). ESWL success was evaluated by stone-free status after the first single session. On average, calculi were 8.0 × 5.3 mm in size, with an SSD of 11.0 cm. The mean CT attenuation value was 740.1 HU. Attenuation numbers correlated significantly with stone diameter (r = 0.49), but had no correlation with the stone content of COM or COD. A negative correlation was observed between COM and COD content (r = -0.925). With regard to patients' physical characteristics and COM and COD content, no differences were found between study subgroups with stone-free and residual status (n = 38 and 15, respectively). There were also no differences in clinical features between patient subgroups with COM- or COD-predominant stones (n = 22 and 31, respectively). The findings indicated that the differences in COM and COD content of CaOx stones had no impact on stone clearance after ESWL and that a favorable stone-free rate of the stones treated with ESWL may be achieved independently of CaOx hydration.

  5. Canada's National Building Stone: Tyndall Stone from Manitoba

    Science.gov (United States)

    Pratt, Brian R.; Young, Graham A.; Dobrzanski, Edward P.

    2016-04-01

    Tyndall Stone is a distinctively mottled and highly fossiliferous dolomitic limestone that belongs to the Selkirk Member of the Red River Formation, of Late Ordovician (Katian) age. It has been quarried at Garson, Manitoba, 37 km northeast of Winnipeg, since 1895, although other quarries in the area go back to 1832. Tyndall Stone, so named because it was shipped by rail from nearby Tyndall, is currently produced by Gillis Quarries Limited. It has various uses as a dimension stone. Large slabs, most often cut parallel to bedding, face the exterior or interior of many important buildings such as the Parliament Buildings and the Canadian Museum of Civilization in the Ottawa area, the Empress Hotel in Victoria, and the provincial legislatures in Winnipeg and Regina, as well as many commercial buildings especially in the Canadian prairies. At the quarries, the stone is cut vertically, using eight foot (2.44 m) diameter saws mounted on one hundred foot (30.5 m) tracks, then split into 6-8 tonne blocks that are moved using front-end loaders. Gillis Quarries operates a large finishing plant with an area of about 4000 m2. Stone is processed along advanced cutting lines that feature eight primary saws and six gantry saw stations, allowing it to be made into a variety of sizes, shapes, and finishes. The Selkirk Member is 43 m thick and the stone is extracted from a 6-8 m thick interval within the lower part. The upper beds tend to be more buff-coloured than the grey lower beds due to weathering by groundwater. The stone is massive, but extracted blocks are less than ~1m thick due to splitting along stylolites. Consisting of bioturbated wackestone to packstone, the Tyndall Stone was deposited in a shallow-marine environment within the photic zone, in the central part of the vast equatorial epicontinental sea that covered much of Laurentia. Scattered thin, bioclastic grainstone lenses record brief, low-energy storm events. The distinctive mottles are formed by dolomitized

  6. Radiographer interpretation of trauma radiographs: Issues for radiography education providers

    International Nuclear Information System (INIS)

    Hardy, Maryann; Snaith, Beverly

    2009-01-01

    Background: The role of radiographers with respect to image interpretation within clinical practice is well recognised. It is the expectation of the professional, regulatory and academic bodies that upon qualification, radiographers will possess image interpretation skills. Additionally, The College of Radiographers has asserted that its aspiration is for all radiographers to be able to provide an immediate written interpretation on skeletal trauma radiographs by 2010. This paper explores the readiness of radiography education programmes in the UK to deliver this expectation. Method: A postal questionnaire was distributed to 25 Higher Education Institutions in the UK (including Northern Ireland) that provided pre-registration radiography education as identified from the Society and College of Radiographers register. Information was sought relating to the type of image interpretation education delivered at pre- and post-registration levels; the anatomical range of image interpretation education; and education delivery styles. Results: A total of 19 responses (n = 19/25; 76.0%) were received. Image interpretation education was included as part of all radiographer pre-registration programmes and offered at post-registration level at 12 academic centres (n = 12/19; 63.2%). The anatomical areas and educational delivery methods varied across institutions. Conclusion: Radiography education providers have embraced the need for image interpretation education within both pre- and post-registration radiography programmes. As a result, UK education programmes are able to meet the 2010 College of Radiographers aspiration.

  7. Ultrasonographic diagnosis of ureteral stones: Accuracy and factors influencing on diagnostic sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Park, Young Mi; Han, Sang Seok; Chang, Seung Kuk; Joo, Sang Hoo; Lee, Jeong Sik; Eun, Choong Ki [Pusan Paik Hospital, Inje University College of Medicine, Pusan (Korea, Republic of)

    1999-12-15

    To determine the accuracy of ultrasonographic diagnosis in patients with clinically suspected ureteral stones and to evaluate the factors influencing on the diagnostic sensitivity for the detection of ureteral stone. The patients (115 cases) with proven presence or absence of ureteral stones were included in the study. At first, both sided kidney and proximal ureters were examined on each decubitus position and then middle ureters were done if proximal ureters were visualized. On the supine view, distal ureters and UVJ were scanned through the acoustic window of the filled bladder. KUB (20 cases), IVU (62 cases), AGP (7 cases), RGP (3 cases), ESWL (9 cases), CT (9 cases), and patients' history of spontaneous passage of stones (5 cases) were included as confirmation methods. The sensitivity, specificity, and accuracy of the ultrasonographic diagnosis of ureteral stones were calculated and the factors influencing on the sensitivity on the focus of the position and size of ureteral stone, visibility of ureter, the presence or absence of renal stone and hydronephrosis were analyzed. Of 82 cases with proven ureteral stone, 72 cases were revealed on ultrasonography and there was one false positive examination among 33 cases with proven absence of ureteral stone. The overall diagnostic accuracy was 90%. The ultrasonographic detection rates of ureteral stones as correlated with their locations were 83% (24/29), 100% (11/11), 80% (16/20), and 100% (21/21) of each group of proximal, middle, distal ureter, and UVJ stones. Of 61 stones, those as correlated with their sizes, were 82% (37/45) and 94% (15/16) of each group less than 10 mm and more than 11 mm. Those as correlated with the presence or absence of ureteral visualization on ultrasonography were 92% (69/75) and 43% (3/7) of each group. Those as correlated with presence of absence of renal stones were 85% (41/48) and 91% (31/34) of each group. Those as correlated with presence or absence of hydronephrosis were 89

  8. The screening pelvic radiograph in pediatric trauma

    International Nuclear Information System (INIS)

    Rees, M.J.; Aickin, R.; Kolbe, A.; Teele, R.L.

    2001-01-01

    Background. Pelvic radiographs are routinely obtained in adult trauma to optimise early management. In adults, pelvic fractures are associated with high early transfusion requirement, high injury severity scores and an increased incidence of other abdominal and thoracic injuries. It is unclear whether this holds true in children. Objective. To determine whether the screening pelvic radiograph is necessary in paediatric trauma. Materials and methods. The notes of all patients who presented after trauma to the Starship Children's Hospital and were triaged to the resuscitation room during 1997 were reviewed. Results of initial radiography were obtained and correlated with later imaging. Results. Our review of 444 injured children seen over a period of 1 year revealed that of 347 children who had screening pelvic radiographs, only 1 had a pelvic fracture. The fracture in this child was clinically apparent and required no specific treatment. Conclusions. The presence of a pelvic fracture is rare in injured children. By omitting screening pelvic radiographs there are potential benefits, including reduced radiation exposure to children and cost savings. Uninterpretable or abnormal clinical examination or haematuria requires further investigation, but routine screening for pelvic fracture is unnecessary. (orig.)

  9. Experience of extracorporeal shock wave lithotripsy for kidney and upper ureteric stones by electromagnetic lithotripter

    International Nuclear Information System (INIS)

    Wazir, B.G.; Haq, M.I.H.; Faheem-ul-Haq; Nawaz, A.; Nawaz, A.; Ikramullah; Jamil, M.

    2010-01-01

    Background: Extracorporeal Shock Wave Lithotripsy (ESWL) is a non-invasive treatment of urinary stones which breaks them, by using externally applied, focused, high intensity acoustic pulse, into smaller pieces so that they can pass easily through ureter. Shock wave generation, focusing, coupling and stone localisation by fluoroscope or ultrasound are the basic components of ESWL. ESWL has some complications and is contraindicated in certain situations. The aim of this study was to evaluate the effectiveness and safety of ESWL in kidney and upper ureteric stones by Electromagnetic Lithotriptor. Methods: All adult patients with renal and upper ureteric stones having a diameter of up to 1 Cm were included in the study. Basic evaluation such as history, examination, ultrasound and excretory urography were performed. Electromagnetic lithotripsy was done and data were collected on a printed proforma from January 1, 2008 to March 30, 2009 in Institute of Kidney Diseases, Peshawar. Results: Out of a total of 625 patients 463 were male and 162 were female; 67.36% of patients were having renal stones, 23.84% upper ureteric and 8.8% both renal and ureteric stones. Complications noted were renal colic in 9.76%, haematuria in 3.2%, stein strasse in 2.72%, and fever in 1.12% of patients. The stone free rate was 89% and 7% of patients were having stone fragments <4 mm. ESWL failed in 4% of patients. Conclusion: ESWL is a safe and effective way of treating kidney and upper ureteric stones. (author)

  10. Ultrasonic propulsion of kidney stones: preliminary results of human feasibility study.

    Science.gov (United States)

    Bailey, Michael; Cunitz, Bryan; Dunmire, Barbrina; Paun, Marla; Lee, Franklin; Ross, Susan; Lingeman, James; Coburn, Michael; Wessells, Hunter; Sorensen, Mathew; Harper, Jonathan

    2014-09-03

    One in 11 Americans has experienced kidney stones, with a 50% average recurrence rate within 5-10 years. Ultrasonic propulsion (UP) offers a potential method to expel small stones or residual fragments before they become a recurrent problem. Reported here are preliminary findings from the first investigational use of UP in humans. The device uses a Verasonics ultrasound engine and Philips HDI C5-2 probe to generate real-time B-mode imaging and targeted "push" pulses on demand. There are three arms of the study: de novo stones, post-lithotripsy fragments, and the preoperative setting. A pain questionnaire is completed prior to and following the study. Movement is classified based on extent. Patients are followed for 90 days. Ten subjects have been treated to date: three de novo , five post-lithotripsy, and two preoperative. None of the subjects reported pain associated with the treatment or a treatment related adverse event, beyond the normal discomfort of passing a stone. At least one stone was moved in all subjects. Three of five post-lithotripsy subjects passed a single or multiple stones within 1-2 weeks following treatment; one subject passed two (1-2 mm) fragments before leaving clinic. In the pre-operative studies we successfully moved 7 - 8 mm stones. In four subjects, UP revealed multiple stone fragments where the clinical image and initial ultrasound examination indicated a single large stone.

  11. Influence of the radiographer on the pain felt during mammography

    International Nuclear Information System (INIS)

    Goethem, M. van; Verslegers, I.; Biltjes, I.; De Schepper, A.; Mortelmans, D.; Bruyninckx, E.; Hove, E. Van

    2003-01-01

    Mammography is the only useful examination in screening for breast cancer. Mortality from breast cancer can be reduced if women go regularly for a screening mammography. Moreover, it is still the key examination in diagnosis of breast diseases and in the follow-up of patients treated for breast cancer. Pain with mammography can deter women from going for regular screening or follow-up; therefore, it is important to reduce pain experience or discomfort from mammography. In this study we evaluate the impact of the ''radiographer'' on the pain risk during mammography by analysing questionnaires filled in by women and radiographers. Study results reveal that the opinion of the radiographer, the information and communication during the examination and the number of years of experience are important factors in pain and discomfort experience. The attitude of the radiographer plays an important role in the pain experience. (orig.)

  12. Radiographically detectable intracortical porosity

    International Nuclear Information System (INIS)

    Meema, H.E.

    1986-01-01

    Since the measurement of intracortical resorptive spaces by histologic methods is difficult and very few data are available in normal humans, we have measured their lengths and widths and calculated the intracortical porosity in metacarpals and phalanges of 79 normal women and 69 normal men, using fine-detail radiographs of the hands and a computerized semi-automatic image analysis system (Zeiss MOP-3), this being the first study of this kind. Several methodological problems were solved satisfactorily, and the results of this study could serve as a data bank for further investigations concerned with intracortical resorption. Significant differences were found between age and sex versus several intracortical resorptive parameters; also significant correlations were found with age in some cases. Normal intracortical porosity was found to be about three times greater in the proximal phalanges than in the metacarpals. It is concluded that this methodology could be used for further studies of intracortical resorption in osteoporosis and other metabolic bone diseases. (orig.)

  13. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  14. Laparoscopic transperitoneal ureterolithotomy for large ureteric stones

    Directory of Open Access Journals (Sweden)

    Ahmed Al-Sayyad

    2012-01-01

    Conclusion: Laparoscopic transperitoneal ureterolithotomy is a safe and effective approach for selected patients with large proximal ureteric stones with reduced postoperative pain and short hospital stay, and should be considered as a treatment option for such stones.

  15. Kidney Stones in Children and Teens

    Science.gov (United States)

    ... Issues Listen Español Text Size Email Print Share Kidney Stones in Children and Teens Page Content Article ... teen girls having the highest incidence. Types of Kidney Stones There are many different types of kidney ...

  16. Radiographic enhancement and analysis system

    International Nuclear Information System (INIS)

    Schlosser, M.S.

    1981-01-01

    Radiographic image enhancement and analysis techniques are discussed as they apply to nondestructive inspection. A system is described which has been developed to enhance and quantitatively evaluate radiographic images using digital computer techniques. Some examples of typical applications are also presented as an introduction to this new inspection technique. (author)

  17. [Detection of Clonorchis sinensis eggs in the ground gallbladder stones by microscopy].

    Science.gov (United States)

    Ma, Rui-Hong; Qiao, Tie; Luo, Xiao-Bing

    2012-08-30

    Sera, feces, bile and gallbladder stones were collected from 179 patients who accepted gallbladder-preserving cholelithotomy during the period of January to June 2010 at the general surgery department in the Second People's Hospital of Panyu District in Guangzhou. Rapid colloidal gold immunochromatography was used to detect IgG against Clonorchis sinensis. C. sinensis eggs were examined by fecal direct smear, and in bile sediments and ground gallbladder stones. The results showed that the positive rate of rapid colloidal gold immunochromatographic assay for IgG was 51.4%, and the egg positive rate in feces, bile sediments and gallbladder stones was 30.7%, 44.7% and 69.8%, respectively. The detection rate of fecal direct smear was the lowest, while that of the gallbladder stone examination was the highest (P stones.

  18. The reliability of tablet computers in depicting maxillofacial radiographic landmarks

    Energy Technology Data Exchange (ETDEWEB)

    Tadinada, Aditya; Mahdian, Mina; Sheth, Sonam; Chandhoke, Taranpreet K.; Gopalakrishna, Aadarsh; Potluri, Anitha; Yadav, Sumit [University of Connecticut School of Dental Medicine, Farmington (United States)

    2015-09-15

    This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

  19. Interpretation and digestion of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    Radiography digestion is final test for the radiography to make sure that radiograph produced will inspect their quality of the image before its interpreted. This level is critical level where if there is a mistake, all of the radiography work done before will be unaccepted. So as mention earlier, it can waste time, cost and more worst it can make the production must shut down. So, this step, level two radiographers or interpreter must evaluate the radiograph carefully. For this purpose, digestion room and densitometer must used. Of course all the procedure must follow the specification that mentioned in document. There are several needs must fill before we can say the radiograph is corrected or not like the location of penetrameter, number of penetrameter that showed, the degree of density of film, and usually there is no problem in this step and the radiograph can go to interpretation and evaluation step as will mentioned in next chapter.

  20. Chesneys' radiographic imaging. 5. ed.

    International Nuclear Information System (INIS)

    Ball, J.; Price, T.

    1989-01-01

    This new edition of Chesney and Chesney: Radiographic Imaging has been completely written by two new authors. The book reflects the change in emphasis in radiology from photographic processes towards electronic imaging methods. There is new material on image intensifiers and television imaging, digital imaging and digital subtractions. Analyses of the various characteristics of, and defects in, images on radiographs, xeroradiographs and the television screen are included. The methods, equipment and materials used to record the cathode ray tube image are described and there is new material on the principles of alternative diagnostic imaging techniques such as ultrasound, computed tomography and radionuclide imaging which provide cathode ray tube images. The book is primarily for student radiographers studying for the Diploma of the College of Radiographers, but radiographers studying for postdiplomate qualifications such as the Higher Diploma (HDCR) will also find the book helpful. (author)

  1. Variability interexaminer of chronic apical periodontitis diagnostics in panoramic radiographs

    International Nuclear Information System (INIS)

    Montero Aguilar, Mauricio; Zeledon Mayorga, Rodolfo; Ramirez Mora, Tatiana; Monestel Umana, Silvia

    2009-01-01

    The accuracy of radiological diagnosis of Apical Periodontitis (AP) is reported between examiners with differents levels of clinical experience using panoramic radiographs. 1032 teeth in 41 panoramic radiographs have been diagnosed. The evaluation of the x-rays and radiological diagnosis is performed by three independent dentists for AP to each tooth. The teeth have presented without radiological signs of AP in 96.6%. The number of teeth classified with an uncertain diagnosis of AP at the has been inversely proportional to the number of years of experience of the examiner. The examiner A has been used as a reference and compared the diagnoses of other examiners.The percentage agreement for all teeth was 95% for examiner B and 94% for examiner C. Kappa for all has been of 0.44 for examiner B and 0.43 for examiner C. The different categories were analyzed separately, the inferior teeth and the anterior teeth have obtained the best results. The level of clinical experience of the examiner has been indifferent in the diagnosis of AP in panoramic radiographs; however, it is important experience in the number of radiographs extras that will be needed to give a radiological diagnosis definitive. The panoramic radiographs were reliable diagnostic tools for AP. (author) [es

  2. Radiographic investigations during medico-legal autopsies

    Energy Technology Data Exchange (ETDEWEB)

    Bratzke, H.; Schneider, V.; Dietz, W.

    1982-04-01

    During the last 13 years (1968-1980), 427 radiographic examinations were carried out during the course of medico-legal autopsies at the Institute of Forensic Medicine at the Free University of Berlin. Important problems were the demonstration of retained foreign bodies resulting from shooting, stabbing or blunt trauma, bone injuries, identification, and the question of life in neonates. An historical survey is given and 12 cases with special forensic problems are illustrated and discussed, and further means of investigations are described.

  3. An improved method for simulating radiographs

    International Nuclear Information System (INIS)

    Laguna, G.W.

    1986-01-01

    The parameters involved in generating actual radiographs and what can and cannot be modeled are examined in this report. Using the spectral distribution of the radiation source and the mass absorption curve for the material comprising the part to be modeled, the actual amount of radiation that would pass through the part and reach the film is determined. This method increases confidence in the results of the simulation and enables the modeling of parts made of multiple materials

  4. Broken Stone Marker Construction%碎石桩施工

    Institute of Scientific and Technical Information of China (English)

    高瑞娥

    2009-01-01

    随着我国高速公路建设的加快,在高速公路的路基设计和施工中引入并使用碎石桩处理软土地基. 文章就结合碎石桩处理软土地基,浅谈碎石桩的施工过程和检测方法.%This paper unifies the broken stone marker processing soft soil ground, discusses the broken stone marker shallowly the construction pro-cess and the examination method.

  5. Radiographic imaging of otitis media and interna in pigs

    International Nuclear Information System (INIS)

    Harlizius, J.; Kluczniok, C.; Bollwahn, W.

    1997-01-01

    Middle and inner ear infections have been reported as a clinical entity in swine, other animal species and humans. In pigs, the anatomical-pathological and microbiological findings have been described. In this report, we describe radiographic findings in affected pigs. A total of 25 pigs with a head tilt and circling, as clinical signs of otitis media and interna, were examined. The majority were weaner-pigs with dyspnea or rhinitis. In radiographs, there was an increased opacity of the bulla tympanica, often accompanied by marginal destruction or thickening of the bulla wall. The radiographic findings confirmed the clinical diagnosis in each affected pig, but there were 5 false positive interpretations

  6. Retrospective assessment of thoracic radiographic findings in metastatic canine hemangiosarcoma

    International Nuclear Information System (INIS)

    Hammer, A.S.; Bailey, M.Q.; Sagartz, J.E.

    1994-01-01

    Twenty-one dogs with histopathologically confirmed hemangiosarcoma were evaluated by thoracic radiography for metastatic disease. All dogs had histopathologic examinations of the lungs within two weeks of thoracic radiography. Fourteen dogs had histopathologic evidence of pulmonary hemangiosarcoma; metastatic disease was detected radiographically in eleven of these dogs. The most common radiographic pattern was that of poorly defined small coalescing nodules (8 dogs); other radiographic patterns included well-circumscribed nodules (3 dogs) and alveolar infiltrates secondary to hemorrhage (2 dogs). Differential diagnoses for diffuse, poorly defined, coalescing pulmonary opacities should include hemangiosarcoma in addition to edema, lymphoma, systemic mycoses, fibrosis, allergy, toxicosis, and carcinomas

  7. Intraperitoneal stone migration during percutaneos nephrolithotomy

    Directory of Open Access Journals (Sweden)

    Akif Diri

    2014-12-01

    Full Text Available Percutaneos nephrolithotomy (PNL is the standard care for renal stones larger than 2 cm. The procedure has some major and minor complications. Renal pelvis laceration and stone migration to the retroperitoneum is one of the rare condition. We report the first case of intraperitoneal stone migration during PNL.

  8. Stone stability under non-uniform flow

    NARCIS (Netherlands)

    Hoan, N.T.

    2008-01-01

    Despite the fact that many studies on the stability of stones in bed protections under flowing water have been conducted, our knowledge is still far from advanced and reliable. Issues like how to quantify the hydraulic loads exerted on the stones on a bed and the associated stability of the stones

  9. Five Stones – Four Rivers – One Town

    DEFF Research Database (Denmark)

    Aktor, Mikael

    2016-01-01

    in northern Nepal to Vallam Town in Tamil Nadu. The chapter examines each of these stones – their visual qualities and their mythological and iconographical associations with their respective deities, the collection, manufacturing and marketing, as well as their present ritual use. It will bring to light...

  10. Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual.

    Science.gov (United States)

    Dang, Natasha Radhika; Moreau, Marc J; Hill, Douglas L; Mahood, James K; Raso, James

    2005-05-01

    Retrospective cross-sectional assessment of the reproducibility and reliability of radiographic parameters. To measure the intra-examiner and interexaminer reproducibility and reliability of salient radiographic features. The management and treatment of adolescent idiopathic scoliosis (AIS) depends on accurate and reproducible radiographic measurements of the deformity. Ten sets of radiographs were randomly selected from a sample of patients with AIS, with initial curves between 20 degrees and 45 degrees. Fourteen measures of the deformity were measured from posteroanterior and lateral radiographs by 2 examiners, and were repeated 5 times at intervals of 3-5 days. Intra-examiner and interexaminer differences were examined. The parameters include measures of curve size, spinal imbalance, sagittal kyphosis and alignment, maximum apical vertebral rotation, T1 tilt, spondylolysis/spondylolisthesis, and skeletal age. Intra-examiner reproducibility was generally excellent for parameters measured from the posteroanterior radiographs but only fair to good for parameters from the lateral radiographs, in which some landmarks were not clearly visible. Of the 13 parameters observed, 7 had excellent interobserver reliability. The measurements from the lateral radiograph were less reproducible and reliable and, thus, may not add value to the assessment of AIS. Taking additional measures encourages a systematic and comprehensive assessment of spinal radiographs.

  11. Treatment of gallbladder stone with common bile duct stones in the laparoscopic era

    OpenAIRE

    Zhang, Wei-jie; Xu, Gui-fang; Huang, Qin; Luo, Kun-lun; Dong, Zhi-tao; Li, Jie-ming; Wu, Guo-zhong; Guan, Wen-xian

    2015-01-01

    Background: Laparoscopic common bile duct exploration (LCBDE) for stone can be carried out by either laparoscopic transcystic stone extraction (LTSE) or laparoscopic choledochotomy (LC). It remains unknown as to which approach is optimal for management of gallbladder stone with common bile duct stones (CBDS) in Chinese patients. Methods: From May 2000 to February 2009, we prospective treated 346 consecutive patients with gallbladder stones and CBDS with laparoscopic cholecystectomy and LCBDE....

  12. Consultant radiographer leadership - A discussion

    International Nuclear Information System (INIS)

    Hogg, Peter; Hogg, Dianne; Henwood, Suzanne

    2008-01-01

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills

  13. The ground stones from Sphinx

    Czech Academy of Sciences Publication Activity Database

    Řídký, Jaroslav

    2017-01-01

    Roč. 2017, č. 21 (2017), s. 39-42 ISSN 1369-5770 Grant - others:GA ČR(CZ) GA17-03207S Institutional support: RVO:67985912 Keywords : Sudan * Mesolithic * ground stones Subject RIV: AC - Archeology, Anthropology, Ethnology OBOR OECD: Archaeology

  14. Pancreatic Stones: Treat or Ignore?

    Directory of Open Access Journals (Sweden)

    DA Howell

    1999-01-01

    Full Text Available Painful, chronic pancreatitis is of complex etiology, but increasing clinical experience suggests that removal of pancreatic duct stones in many cases significantly improves patients’ symptoms. The development and refinement of therapeutic endoscopic retrograde choledochopancreatography have permitted improved access to the pancreatic duct, which makes the development of new techniques of stone fragmentation and fragment removal a much more successful nonsurgical intervention. A major step forward has been the understanding of the safety and efficacy of pancreatic sphincterotomy, which is necessary for the removal of these difficult stones. The recognition that extracorporeal shock wave lithotripsy can be delivered safely with good efficacy has revolutionized the nonsurgical management of pancreatic duct stones. Nevertheless, advanced and sophisticated therapeutic endoscopy is necessary to achieve clearance of the duct, which can generally be accomplished in the majority of selected patients. State-of-the-art treatments are described, and some new approaches using pancreatoscopy and electrohydrolic lithotripsy are discussed. Newly recognized long term complications are reviewed. Finally, it must be recognized that chronic pancreatitis is an ongoing disease that does not have a simple treatment or cure, and frequently represents a process of remissions and relapses requiring interventions and problem solving.

  15. Stones used in Milan architecture

    Directory of Open Access Journals (Sweden)

    Folli, Luisa

    2008-06-01

    Full Text Available The city of Milan lies in a plain with clayey soil well suited to brick-making, but no stone deposits. An ample supply of stone is available, however, in the surrounding hills and mountains, which are connected to the city via both natural and artificial waterways. The types of stone used since Roman times include: granite, marble and gneiss from Ossola Valley; dolomite from Lake Maggiore; detrital limestone from Ceresio Valley; sandstone from the Brianza Hills; black limestone and marble from Lake Como; and conglomerate and sandstone from the Adda River basin. Traditionally, the chief uses have been dimension stone (all stones, column shafts (granite, slabs (marble, moulding (dolomite, limestone and ornamental (marble, dolomite, limestone.La ciudad de Milán se encuentra en una llanura de suelo arcilloso adecuado para la fabricación de ladrillos pero en la cual no hay yacimientos de rocas. No obstante, en las colinas y montañas circundantes, que están comunicadas con la ciudad mediante vías navegables naturales y artificiales, sí existe una abundante cantidad de piedra. Entre los tipos de piedra utilizados desde la época de los romanos se encuentran granitos, mármoles y gneises del valle de Ossola, dolomías del lago Mayor, calizas detríticas del valle de Ceresio (Lugano, areniscas de las colinas de la Brianza, calizas negras y mármoles del lago Como y conglomerados y areniscas de la cuenca del río Adda. Tradicionalmente, los principales usos han sido la piedra de fábrica (todas ellas, fustes de columnas (granito, losas (mármol, molduras (dolomía, caliza y ornamental (mármol, dolomía, caliza.

  16. Role of a radiographer in mammography- new perspective

    International Nuclear Information System (INIS)

    Malik, S.

    2006-01-01

    giving the background to breast cancer in kenya. The importance of public education. The significance of early detection of breast cancer and patient survival. the emphasis of change of mind set of machine oriented radiographer to a clinically focused role. this involves a better understanding of the breast, the disease pattern, clinical examination of the breast and correlation with radiographic findings. The importance of other imaging modalities used to supplement mammography

  17. Radiographic scanner apparatus

    International Nuclear Information System (INIS)

    Wake, R.H.

    1980-01-01

    The preferred embodiment of this invention includes a hardware system, or processing means, which operates faster than software. Moreover the computer needed is less expensive and smaller. Radiographic scanner apparatus is described for measuring the intensity of radiation after passage through a planar region and for reconstructing a representation of the attenuation of radiation by the medium. There is a source which can be rotated, and detectors, the output from which forms a data line. The detectors are disposed opposite the planar region from the source to produce a succession of data lines corresponding to the succession of angular orientations of the source. There is a convolver means for convolving each of these data lines, with a filter function, and a means of processing the convolved data lines to create the representation of the radiation attenuation in the planar region. There is also apparatus to generate a succession of data lines indicating radiation attenuation along a determinable path with convolver means. (U.K.)

  18. Effect of eliminating administrative radiographs on patient exposure and accuracy of provisional treatment plans

    International Nuclear Information System (INIS)

    Kantor, M.L.; Slome, B.A.

    1987-01-01

    Published reports and recommendations suggest that radiographs are often ordered because of administrative policies during the screening and selection of patients for dental school clinics. This study examined the prescription of radiographs for two groups of patients: those who were radiographically examined according to an administrative policy and those whose radiographic needs were determined by a clinical examination. The provisional treatment needs assessment based on the screening examination was compared to the final treatment plan based on a complete diagnostic workup for both groups of patients to assess the effect of a change in school policy. Clinicians ordered half the number of panoramic radiographs as would have been ordered by administrative policy. There was no significant difference in the agreement between the provisional and final treatment plans under the two policies. These results suggest that dental schools can comply with federal recommendations against administrative radiographs without compromising patient selection

  19. Management of ureteric stone in pediatric patients

    Directory of Open Access Journals (Sweden)

    Eugene Minevich

    2010-01-01

    Full Text Available The management of ureteral stones in children is becoming more similar to that in adults. A number of factors must be taken into account when selecting one′s choice of therapy for ureteral stone in children such as the size of the stone, its location, its composition, and urinary tract anatomy. Endoscopic lithotripsy in children has gradually become a major technique for the treatment of ureteral stones. The stone-free rate following urteroscopic lithotripsy for ureteral stones has been reported in as high as 98.5-100%. The safety and efficacy of Holmium:YAG laser lithotripsy make it the intracorporeal lithotriptor of choice. Given its minimally invasive features, extracorporeal shock wave lithotripsy (ESWL has become a primary mode of treatment for the pediatric patients with reno-ureteral stones. Stone-free rates have been reported from 59% to 91% although some patients will require more than one treatment session for stone clearance. It appears that the first-line of therapy in the child with distal and mid-ureteral stones should be ureteroscopic lithotripsy. While ESWL is still widely considered the first-line therapy for proximal ureteral calculi, there is an increasing body of evidence that shows that endoscopic or ESWL are equally safe and efficacious in those clinical scenarios. Familiarity with the full spectrum of endourological techniques facilitates a minimally invasive approach to pediatric ureteral stones.

  20. The radiographic image: A cultural artefact?

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.

    2014-01-01

    This article looks at the role of the radiographic images produced by diagnostic radiographers. An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article. The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient. The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer

  1. The possibility of use of Kremicj granitoid (Serbia) as an architectural stone

    International Nuclear Information System (INIS)

    Kureshevicj, Lidja

    2010-01-01

    The stone from the granitoid pluton of Kremić in southern Serbia has been examined in order to evaluate the possibility of its use as an architectural stone. Both field observations and laboratory testing of specimens have been performed. Although the specimens were collected from the field surface level, their physicomechanical lab test results have shown that the rock mass itself fulfils all the requirements for use as an architectural stone set by the State through Serbian standards. Also, the stone quality is higher in deeper ground levels, where the weathering agents have less intense effects. This stone does not have high ornamental properties, but it has a finegrained texture and low mica content which has a positive effect on its technical characteristics and susceptibility to processing. (Author)

  2. Puncture wounds into the navicular bursa of the horse: role of radiographic evaluation

    International Nuclear Information System (INIS)

    Richardson, G.L.; O'Brien, T.R.

    1985-01-01

    Radiography was used to evaluate 32 horses presented for puncture wounds into the navicular bursa. At the initial radiographic examination, 21 horses had no radiographic signs of osteomyelitis, while 11 did. The mean-time interval between injury and radiographic examination was 20.6 days for horses without evidence of osteomyelitis and 59.3 days for those with evidence of osteomyelitis. Radiographic signs of osteomyelitis of the navicular bone included flexor cortical destruction and irregularity of the flexor surface. Other abnormalities included pathologic fracture of the navicular bone, subluxation of the distal interphalangeal joint, or secondary joint disease. The lateromedial and palmaroproximal-palmarodistal oblique projections were most useful for identifying abnormalities of the navicular bone. There was a high correlation between horses that had positive presurgical radiographic signs and surgical findings. However, approximately 50% of horses that had negative radiographic findings initially had positive surgical findings. Ten of 21 horses with negative radiographic findings on initial examination had evidence of bony lesions when reevaluated from 3 weeks to 6 years later. Nine of 11 horses with radiographic signs of osteomyelitis on initial radiographic examination were euthanatized or had an unsatisfactory outcome. Seven of 10 horses with radiographic signs on reexamination were euthanatized. Thirteen of 20 horses with positive surgical findings for navicular bone infection were euthanatized or had an unsatisfactory outcome

  3. Open stone surgery: a still-in-use approach for complex stone burden.

    Science.gov (United States)

    Çakici, Özer Ural; Ener, Kemal; Keske, Murat; Altinova, Serkan; Canda, Abdullah Erdem; Aldemir, Mustafa; Ardicoglu, Arslan

    2017-06-30

    Urinary stone disease is a major urological condition. Endourologic techniques have influenced the clinical approach and outcomes. Open surgery holds a historic importance in the management of most conditions. However, complex kidney stone burden may be amenable to successful results with open stone surgery. In this article, we report our eighteen cases of complex urinary stone disease who underwent open stone removal. A total of 1701 patients have undergone surgical treatment for urinary stone disease in our clinic between July 2012 and July 2016, comprising eighteen patients who underwent open stone surgery. Patients' demographic data, stone analysis results, postoperative clinical data, and stone status were evaluated retrospectively. The choice of surgical approach is mostly dependent on the surgeon's preference. In two patients, open surgery was undertaken because of perioperative complications. We did not observe any Clavien-Dindo grade 4 or 5 complications. Three patients were managed with a course of antibiotics due to postoperative fever. One patient had postoperative pleurisy, one patient had urinoma, and two patients had postoperative ileus. Mean operation time was 84 (57-124) minutes and mean hospitalization time was 5.5 (3-8) days. Stone-free status was achieved in 15 patients (83.3%). Endourologic approaches are the first options for treatment of urinary stone disease. However, open stone surgery holds its indispensable position in complicated cases and in complex stone burden. Open stone surgery is also a valid alternative to endourologic techniques in all situations.

  4. Coronal reconstruction of unenhanced abdominal CT for correct ureteral stone size classification

    Energy Technology Data Exchange (ETDEWEB)

    Berkovitz, Nadav; Simanovsky, Natalia; Hiller, Nurith [Hadassah Mount Scopus - Hebrew University Medical Center, Department of Radiology, Jerusalem (Israel); Katz, Ran [Hadassah Mount Scopus - Hebrew University Medical Center, Department of Urology, Jerusalem (Israel); Salama, Shaden [Hadassah Mount Scopus - Hebrew University Medical Center, Department of Emergency Medicine, Jerusalem (Israel)

    2010-05-15

    To determine whether size measurement of a urinary calculus in coronal reconstruction of computed tomography (CT) differs from stone size measured in the axial plane, and whether the difference alters clinical decision making. We retrospectively reviewed unenhanced CT examinations of 150 patients admitted to the emergency room (ER) with acute renal colic. Maximal ureteral calculus size was measured on axial slices and coronal reconstructions. Clinical significance was defined as an upgrading or downgrading of stone size according to accepted thresholds of treatment: {<=}5 mm, 6-9 mm and {>=}10 mm. There were 151 stones in 150 patients (male:female 115:34, mean age 41 years). Transverse stone diameters ranged from 1 to 11 mm (mean 4 mm). On coronal images, 56 (37%) stones were upgraded in severity; 46 (30%) from below 5 mm to 6 mm or more, and ten (7%) from 6-9 mm to 10 mm or more. Transverse measurement on the axial slices enabled correct categorization of 95 stones (63%). Transverse calculus measurement on axial slices often underestimates stone size and provides incorrect clinical classification of the true maximal stone diameter. Coronal reconstruction provides additional information in patients with renal colic that may alter treatment strategy. (orig.)

  5. Coronal reconstruction of unenhanced abdominal CT for correct ureteral stone size classification

    International Nuclear Information System (INIS)

    Berkovitz, Nadav; Simanovsky, Natalia; Hiller, Nurith; Katz, Ran; Salama, Shaden

    2010-01-01

    To determine whether size measurement of a urinary calculus in coronal reconstruction of computed tomography (CT) differs from stone size measured in the axial plane, and whether the difference alters clinical decision making. We retrospectively reviewed unenhanced CT examinations of 150 patients admitted to the emergency room (ER) with acute renal colic. Maximal ureteral calculus size was measured on axial slices and coronal reconstructions. Clinical significance was defined as an upgrading or downgrading of stone size according to accepted thresholds of treatment: ≤5 mm, 6-9 mm and ≥10 mm. There were 151 stones in 150 patients (male:female 115:34, mean age 41 years). Transverse stone diameters ranged from 1 to 11 mm (mean 4 mm). On coronal images, 56 (37%) stones were upgraded in severity; 46 (30%) from below 5 mm to 6 mm or more, and ten (7%) from 6-9 mm to 10 mm or more. Transverse measurement on the axial slices enabled correct categorization of 95 stones (63%). Transverse calculus measurement on axial slices often underestimates stone size and provides incorrect clinical classification of the true maximal stone diameter. Coronal reconstruction provides additional information in patients with renal colic that may alter treatment strategy. (orig.)

  6. Radiographic film cassette unloading apparatus

    International Nuclear Information System (INIS)

    Stievenart, E.F.; Plessers, H.S.; Neujens, G.J.

    1980-01-01

    Apparatus for unloading cassettes, containing exposed radiographic films, has means for unfastening the cassettes, an inclined pathway for gravity feeding and rotating feed members (rollers or belts) to propel the films into the processor. (UK)

  7. Method for taking X radiographs

    International Nuclear Information System (INIS)

    Orth, G.

    1983-01-01

    The method is aimed at obtaining X radiographs of any human organ with the aid of an X-ray-shadowless radiation detector of a dose measuring device, which is arranged between patient and imaging system, and of a controlling microprocessor system, so that the image-forming parameters are automatically adjusted to the specific properties of the patient. This procedure minimices the efforts in preparing the radiograph and the radiation exposure of the patient

  8. Film holder for radiographing tubing

    International Nuclear Information System (INIS)

    Davis, E.V.; Foster, B.E.

    1976-01-01

    A film cassette is described which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro

  9. The radiographic manifestations of hypochondroplasia

    International Nuclear Information System (INIS)

    Heselson, N.G.; Cremin, B.J.; Beighton, P.

    1979-01-01

    Hypochrondroplasia is an inherited skeletal dysplasia that resembles achondroplasia in mild degree. Radiographic manifestations encountered in 12 affected individuals in South Africa include slight shortening of all segments of the tubular bones, moderate caudal diminution of the lumbar interpedicular distances, increased lumbar lordosis with cacral tilt and distal prolongation of the fibular. Hypochondroplasia can be distinguished from other osteochondrodystrophies such as achondroplasia, pseudo-achondroplasia and metaphyseal chondroplasia by the recognition of it clinical and radiographic manifestations. (author)

  10. Film holder for radiographing tubing

    Science.gov (United States)

    Davis, Earl V.; Foster, Billy E.

    1976-01-01

    A film cassette is provided which may be easily placed about tubing or piping and readily held in place while radiographic inspection is performed. A pair of precurved light-impervious semi-rigid plastic sheets, hinged at one edge, enclose sheet film together with any metallic foils or screens. Other edges are made light-tight with removable caps, and the entire unit is held securely about the object to be radiographed with a releasable fastener such as a strip of Velcro.

  11. Improvements in or relating to radiographic apparatus

    International Nuclear Information System (INIS)

    Hounsfield, G.N.

    1978-01-01

    Radiographic apparatus is described for examining part of the interior of a body by means of penetrating radiation including a packing member comprising a bag containing particulate or viscous material, having an absorption to the radiation similar to that of human tissue, the member as a whole being flexible and being adapted to be placed in contact with the body in the vicinity of the part to be examined. Locating means, arranged to maintain the member in place, and means for disposing the locating means in a predetermined position with respect to the source of the radiation are provided. (author)

  12. Bariatric Surgery and Stone Disease

    Science.gov (United States)

    Lieske, John C.; Kumar, Rajiv

    2008-09-01

    Bariatric surgery is an effective treatment strategy for patients with morbid obesity that can result in effective weight loss, resolution of diabetes mellitus and other weight related complications, and even improved mortality. However, it also appears that hyperoxaluria is common after modern bariatric surgery, perhaps occurring in up to 50% of patients after Rouxen-Y gastric bypass. Although increasing numbers of patients are being seen with calcium oxalate kidney stones after bariatric surgery, and even a few with oxalosis and renal failure, the true risk of these outcomes remains unknown. The mechanisms that contribute to this enteric hyperoxaluria are also incompletely defined, although fat malabsorption may be an important component. Since increasing numbers of these procedures are likely to be performed in the coming years, further study regarding the prevalence and mechanisms of hyperoxaluria and kidney stones after bariatric surgery is needed to devise effective methods of treatment in order to prevent such complications.

  13. Radiographic bone loss in a Scottish non-smoking Type 1 Diabetes mellitus population; a Bitewing Radiographic Study.

    Science.gov (United States)

    Plessas, Anastasios; Robertson, Douglas P; Hodge, Penny J

    2018-05-15

    The dental complications of uncontrolled diabetes include reduced salivary flow rate, candidiasis and periodontal manifestations. A recent meta-analysis concluded that diabetes patients have a significantly higher severity, but not extent, of destructive periodontal disease than non-diabetes people. The authors reported that most type-1 diabetes studies using dental radiographic data have not controlled for confounding factors such as smoking. The aim of this cross-sectional study was to compare radiographic alveolar bone loss between type 1 diabetes (T1DM) and non-diabetes (NDM) participants in a Scottish non-smoking population. Digital bitewing radiographs for 174 Scottish adult never or ex-smoker (> 5 years) participants (108 T1DM, 66 NDS), recruited from outpatient clinics throughout Greater Glasgow and Clyde, were included in the analysis. A single blinded, trained and calibrated examiner recorded the radiographic bone loss seen on bitewing radiographs using the digital screen caliper. The bone loss was measured as the distance between the cemento-enamel junction (CEJ) and the deepest radiographic alveolar bone margin interproximally of each tooth. T1DM participants had more radiographic alveolar bone loss throughout the all teeth measured (median:1.27 mm vs 1.06 mm, P diabetes subjects. Patients suffering from type 1 diabetes are at higher risk of periodontitis even when controlling for multiple possible confounding factors and this difference can be detected on routine dental radiographs at an early stage. These data confirm radiographically the previously reported association between T1DM and periodontal bone loss. This article is protected by copyright. All rights reserved. © 2018 American Academy of Periodontology.

  14. Complications from radiographer-performed double contrast barium enemas

    Energy Technology Data Exchange (ETDEWEB)

    Vora, P.; Chapman, A. E-mail: anthony.chapman@leedsth.nhs.uk

    2004-04-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted.

  15. Complications from radiographer-performed double contrast barium enemas

    International Nuclear Information System (INIS)

    Vora, P.; Chapman, A.

    2004-01-01

    AIM: To determine the types and rates of complications encountered by radiographers when performing double contrast barium enemas (DCBE). MATERIALS AND METHODS: Seven hundred and forty-one questionnaires were posted to radiographers who had in the last 5 years attended one of the biannual barium enema training courses. RESULTS: Of 741 questionnaires posted 407 (54.9%) were returned completed. Approximately 348,000 barium enema examinations had been performed. Fifty-nine radiographers reported 89 complications, including 13 intra-peritoneal and 11 extra-peritoneal perforations. There were five deaths (mortality 1 in 70,000). Deaths resulted from two of 24 (10%) perforations, two of 45 (5%) cardiac events and one cerebrovascular accident that occurred during an examination. CONCLUSIONS: Radiographers have been regularly performing DCBEs for almost a decade. The mortality for radiographer-performed DCBE is similar to that previously reported for radiologists, although a slightly higher rate of perforation is noted and so this is an area where radiographer training should be targeted

  16. Greco-Roman Stone Disease

    Science.gov (United States)

    Moran, Michael E.; Ruzhansky, Katherine

    2008-09-01

    Greek and Roman thought had a profound influence upon Western medical practice. From the fall of the Greek civilization to the fall of the Roman, remarkable progress of our understanding of human anatomy and physiology occurred. Here we review the attempts of Greek and Roman thinkers to develop the first understanding of the pathophysiology of urolithiasis, its epidemiology, differential diagnosis of renal versus bladder stones, medications for both colic and prevention, the role of familial syndromes, and dietary management.

  17. Measuring anteversion in the femoral neck from routine radiographs

    International Nuclear Information System (INIS)

    Hermann, K.L.; Egund, N.

    1998-01-01

    Purpose: To describe a new method for measuring femoral neck anteversion (FNA) that requires only one lateral radiograph of the knee in addition to routine radiographs of the hip for evaluation of total hip replacement; and to compare the proposed method with FNA measurement by means of 3D CT. Material and Methods: In 18 femoral specimens, radiographic examinations of the hip and knee, in three different rotational positions, and one CT examination were made, and the measurements of FNA were compared. Similarly, in 38 patients with 40 total hip replacements, measurements form routine radiographic examinations of the hip and knee and from CT examinations were compared. The accuracy and reproducibility of the FNA measurements produced by this proposed method were calculated. Results: Accuracy and reproducibility were 2 and 2 for the proposed method in the femoral specimen study, and accuracy was 4 in the hip patient study. The proposed method had a minor flaw that was caused almost solely by differences in knee size at inward rotation of the femur. Conclusion: FNA measurement can be made from a routine radiographic examination of the hip and a lateral view of the knee. This method achieves an acceptable level of accuracy and reproducibility. (orig.)

  18. [The importance of conventional radiographs in the diagnosis of osteosarcoma].

    Science.gov (United States)

    Meyer, S; Reinhard, H; Graf, N; Püschel, W; Ziegler, K; Schneider, G

    2002-01-01

    We report about a 12-year-old boy with a history of recurrent patella luxation. Due to persistent pain in the distal left femur a MRI examination was performed in another hospital which suggested a malignant bone tumor. Without validation of the MRI findings by conventional radiographs bone biopsy was performed. Histopathological examination yielded the diagnosis of a chondroblastic osteosarcoma. Before initiating polychemotherapy, plain radiographs for the first time, a nuclear imaging study and an additional MRI examination were performed in our hospital. The results of these studies made the diagnosis of an osteosarcoma unlikely. In particular, plain radiographs did not show any osseous lesion which was characteristic of an osteosarcoma. To establish a definite diagnosis biopsy was repeated with resection of the bone area which showed suspicious changes in MRI studies. An osteosarcoma was ruled out by histopathological examination. The pathologic changes detected in MRI were rated as bone bruise on plain radiographs and seemed to be of traumatic origin. Our case report emphasises the importance of conventional radiographs in establishing the diagnosis of an osteoarcoma respectively bone tumors and tumor-like lesions in general. They still remain the mainstay in diagnosing bone forming tumors. MRI imaging studies may show changes which mimick solid lesions but in deed can be of traumatic origin. Without informing the pathologist about the exact origin of the specimen, histopathological examination may lead to the misdiagnosis of a chondroblastic osteosarcoma if specimen, like in this case report, represents epiphyseal tissue showing cartilaginous areas with reactive bone formation.

  19. Nosocomial Legionnaires’ Disease: Clinical and Radiographic Patterns

    Directory of Open Access Journals (Sweden)

    Thomas J Marrie

    1992-01-01

    Full Text Available From 1981 to 1991, 55 patients (33 males, 22 females, mean age 58.6 years with nosocomial Legionnaires’ disease were studied. The mortality rate was 64%. One-half of the patients developed nosocomial Legionnaires’ disease within three weeks of admission. A surprising clinical feature was the low rate of findings of consolidation on physical examination, despite the fact that 52% of patients had this finding on chest radiograph. More than one-half of patients had pre-existing lung disease, rendering a radiographic diagnosis of pneumonia due to Legionella pneumophila impossible in 16% of cases despite microbiological confirmation. Nineteen per cent of patients who had blood cultures done had a pathogen other than L pneumophila isolated, suggesting dual infection in at least some of the patients. When the clinical and radiographic findings were combined it was noted that 40% of patients had one of three patterns suggestive of nosocomial Legionnaires’ disease: rapidly progressive pneumonia, lobar opacity and multiple peripheral opacities. However, in 60% of patients there were no distinctive features.

  20. Consultant radiographer leadership - A discussion

    Energy Technology Data Exchange (ETDEWEB)

    Hogg, Peter [Directorate of Radiography, University of Salford, Allerton Building, Frederick Road, Salford, Greater Manchester M6 6PU (United Kingdom)], E-mail: p.hogg@salford.ac.uk; Hogg, Dianne [Henwood Associates (South East) Ltd, Company Number: 513796, Registered Office: 2 Lakeview Stables, Lower St Clere, Kemsing, Kent, TN15 6NL (United Kingdom); Henwood, Suzanne [East Lancashire Primary Care Trust, Linden Business Centre, Linden Road, Colne. BB8 9BA (United Kingdom)

    2008-12-15

    Effective leadership can be defined in many ways and is an essential element of successful organisations; poor leadership can result in problems such as low staff morale, high staff turnover and reduced productivity. Effective leadership behaviours are well documented in the literature and various leadership models have been proposed that illustrate these behaviours. This discussion paper does not focus on any particular model. Instead it considers the 'Leadership Qualities Framework' which was developed specifically for use within the UK National Health Service. This framework draws upon a range of leadership models and as such it gives a broad indication of leadership behaviours. The framework comprises three components - 'personal qualities', 'setting direction' and 'delivering the service'. This paper commences with an argument as to why effective leadership is important in organisations generally, and specifically within healthcare organisations. Various examples of leadership are illustrated from within and outside the NHS in order to demonstrate effective leadership behaviours. The Leadership Qualities Framework is then examined, along with scenarios to illustrate effective leadership behaviours in context (i.e. within a healthcare organisation). Subsequent reflections on the scenarios aim to identify leadership behaviours that are explained within the framework. The final element of this paper draws on [limited] published evidence of where consultant radiographers have demonstrated effective leadership behaviours. In this section the published evidence is examined and reflected upon. At the end of the article we indicate additional reading for those who wish to further develop their theoretical and practical leadership skills.

  1. Radiographic testing at Lawrence Livermore National Laboratory

    International Nuclear Information System (INIS)

    Bossi, R.H.

    1982-01-01

    Radiographic testing is a nondestructive inspection technique which uses penetrating radiation. The Nondestructive Evaluation (NDE) Section at Lawrence Livermore National Laboratory has a broad spectrum of equipment and techniques for radiographic testing. These resources include low-energy vacuum systems, low- and mid-energy cabinet and cell radiographic systems, high-energy linear accelerators, portable x-ray machines and radioisotopes for radiographic inspections. For diagnostic testing the NDE Section also has real-time and flash radiographic equipment

  2. Reproductive health of male radiographers

    International Nuclear Information System (INIS)

    Shakhatreh, Farouk M.

    2001-01-01

    To compare certain reproductive health problems reported in 2 groups of males, one of which was exposed to x-ray radiation (radiographers) and the other group that was not exposed to x-ray radiation. The reproductive health problems were miscarriage, congenital anomalies, still births and infertility. Two groups of men were selected (90 in each group). The first group consisted of radiographers and the other groups consisted of men not exposed to x-ray radiation. The 2 groups were matched for age and source. Relative risk, attributable risk percentage and level of significance were calculated. Incidence rate of reproductive health problems was increasing with the increase in duration of exposure to x-ray radiation ranging between 17% (for those exposed for 1-5 years) to 91% (for those exposed for more than 15 years). There were significant associations between exposure to radiation and miscarriage (relative risk = 1.67, attributable risk percentage = 40%), congenital anomalies (relative risk = 10, attributable risk percentage 90%), still birth (relative risk = 7, attributable risk percentage = 86%), and infertility (relative risk = 4.5, attributable risk = 78%). The incidence rates of reproductive health problems reported by male radiographers were significantly higher than that reported by the non exposed group and higher than the incidence rates reported in community-based studies in Jordan. The incidence rates of fetal death (miscarriage and stillbirth together) and infertility reported by our radiographers were higher than had been reported by the British radiographers. An immediate plan of action is needed to protect our radiographers. Further studies are needed in this field taking into account all extraneous variables that may affect the reproductive health of radiographers. (author)

  3. Emergency management of ureteral stones: Recent advances

    Directory of Open Access Journals (Sweden)

    Luis Osorio

    2008-01-01

    Full Text Available Most ureteral stones can be observed with reasonable expectation of uneventful stone passage. When an active ureteral stone treatment is warranted, the best procedure to choose is dependent on several factors, besides stone size and location, including operators′ experience, patients′ preference, available equipment and related costs. Placement of double-J stent or nephrostomy tube represents the classical procedures performed in a renal colic due to acute ureteral obstruction when the conservative drug therapy does not resolve the symptoms. These maneuvers are usually followed by ureteroscopy or extracorporeal shockwave lithotripsy, which currently represent the mainstay of treatment for ureteral stones. In this review paper a literature search was performed to identify reports dealing with emergency management of renal colic due to ureteral stones. The main aspects related to this debated issue are analyzed and the advantages and disadvantages of each treatment option are carefully discussed.

  4. Emergency management of ureteral stones: Recent advances.

    Science.gov (United States)

    Osorio, Luis; Lima, Estêvão; Autorino, Riccardo; Marcelo, Filinto

    2008-10-01

    Most ureteral stones can be observed with reasonable expectation of uneventful stone passage. When an active ureteral stone treatment is warranted, the best procedure to choose is dependent on several factors, besides stone size and location, including operators' experience, patients' preference, available equipment and related costs. Placement of double-J stent or nephrostomy tube represents the classical procedures performed in a renal colic due to acute ureteral obstruction when the conservative drug therapy does not resolve the symptoms. These maneuvers are usually followed by ureteroscopy or extracorporeal shockwave lithotripsy, which currently represent the mainstay of treatment for ureteral stones. In this review paper a literature search was performed to identify reports dealing with emergency management of renal colic due to ureteral stones. The main aspects related to this debated issue are analyzed and the advantages and disadvantages of each treatment option are carefully discussed.

  5. A radiographic study of mental foramen in intraoral radiographs

    International Nuclear Information System (INIS)

    Sohn, Jeong Ick; Choi, Karp Shik

    1995-01-01

    The purpose of this study was to evaluate the position and shape of mental foramen in periapical radiographs. For this study, periapical radiographs of premolar areas were obtained from the 200 adults. Accordingly, the positional and shape changes of mental foramen were evaluated. The authors obtained radiographs according to changes in radiation beam direction in periapical radiographs of premolar areas, and then evaluated the positional and shape changes of mental foramen. The following results were obtained: 1. Shapes of mental foramen were observed elliptical (34.3%), round or oval (28.0%), unidentified (25.5%) and diffuse (12.2%) type in descending order of frequency. 2, Horizontal positions of mental foramen were most frequently observed at the 2nd premolar area (55.3%), the area between the 1st premolar and 2nd premolar (39.6%), the area between the 2nd premolar and 1st molar (3.4%), the 1st premolar area (1.0%), the area between the canine and 1st premolar (0.7%) in descending order of frequency. 3. Vertical positions of mental foramen were most frequently observed at the inferior to apex (67.1%), and at apex (24.8%), overlap with apex (6.4%), superior to apex (1.7%) in descending order of frequency. 4. Shapes of mental foramen were more obviously observed at the upward 10 degree positioned periapical radiographs. And according to the changes of horizontal and vertical position, they were observed similar to normally positioned periapical radiographs.

  6. Radiologic examination

    International Nuclear Information System (INIS)

    Thoeni, R.F.

    1989-01-01

    The radiographic examination of the upper and lower gastrointestinal tract has been changed drastically by the introduction of endoscopic procedures that are now widely available. However, the diagnostic approach to the small bowel remains largely unchanged. Ultrasonography, computed tomography (CT), and magnetic resonance imaging (MRI) are occasionally employed but are not primary imaging modalities for small bowel disease. Even though small bowel endoscopes are available, they are infrequently used, and no scientific paper on their employment has been published. Barium studies are still the mainstay for evaluating patients with suspected small bowel abnormalities. This paper discusses the anatomy and physiology of the small bowel and lists the various types of barium and pharmacologic aids used for examining it. The different radiographic methods for examining the small bowel with barium, including SBFT, dedicated SBFT, enteroclysis, peroral pneumocolon (PPC), and retrograde small bowel examination, are described and put into perspective. To some degree such an undertaking must be a personal opinion, but certain conclusions can be made based on the available literature and practical experience. This analysis is based on the assumption that all the various barium techniques are performed with equal expertise by the individual radiologist, thus excluding bias from unfamiliarity with certain aspects of a procedure, such as intubation or skilled compression during fluoroscopy. Also, the use of water-soluble contrast material, CT, and MRI for evaluating suspected small bowel abnormalities is outlined

  7. COMORBIDITY OF KIDNEY STONES AND PYCHIATRIC DISEASE

    OpenAIRE

    Bilić, Vedran; Marčinko, Darko

    2010-01-01

    This paper describes a patient who is suffering from PTSD with elements of hypochondria, panic attacks and episodes of 0depression in comorbidity with kidney stones. Kidney stones provoked egzacerbation of psychiatric symptoms. Kidney stones and frustration about them have taken part of provoking factor, the last drop, which led to regression of otherwise precarious, but compensated patient’s mental functioning which resulted in development of psychiatric symptoms.

  8. [Sialoendoscopy-assisted sialolithectomy for large parotid stones].

    Science.gov (United States)

    Zhao, Jian; Zhang, Lei; Liu, Deng-gao; Zhang, Zu-yan; Yu, Guang-yan

    2014-02-18

    To explore the clinical application of endoscope-assisted operative retrieval of large parotid stones as a minimally invasive alternative. From January 2010 to April 2013, 6 patients (male: 5, female: 1, age from 30-62 years, and median age: 49.5 years)suffering from recurred swelling of parotid gland due to sialoliths were treated by endoscope-assisted parotid surgery in Peking University School and Hospital of Stomatology. All of the patients underwent clinical, ultrasonographic and cone-beam CT (CBCT) examinations to get the detailed information of the number, location and size of stones, which was recorded in the medical records. endoscope-assisted parotid surgery was performed under general anesthesia in all the 6 cases after the failure of basket or forcep retrieval firstly. During the operation, sialoendoscope was used to locate the stone exactly and then the calculus was exposed through a pre-auricular approach and released by incising the duct. The postoperative complications were recorded and observed during the follow-up periods. Preoperative radiological examinations showed that all of the sialoliths were near the hilum of parotid gland ducts in the 6 cases, which were 5-9 mm in diameter. All of the stones were removed successfully by endoscope-assisted operative retrieval. The incisions healed smoothly in all the 6 cases. There were no cases of facial nerve weakness, infection or salivary fistula. After a mean follow-up of 19 months (ranging from 6-36 months), 5 patients remained asymptomatic and 1 patient had mild obstructed or infective symptoms. The final results were satisfied. It is suggested that endoscope-assisted operative retrieval is a viable minimally invasive alternative to remove the large or recalcitrant parotid stones with a high successful rate and low complications.

  9. A Bile Duct Stone Formation around a Fish Bone as a Nidus after Pancreatoduodenectomy

    Directory of Open Access Journals (Sweden)

    Tomoki Sakakida

    2018-02-01

    Full Text Available We report a rare case of bile duct stone formation around an ingested fish bone as a nidus after pancreatoduodenectomy. A 78-year-old woman was admitted to our department for fever and epigastric pain. Abdominal computed tomography revealed an elongated bile duct stone containing a linearly shaped foreign body of bone density. Enteroscopic lithotomy was performed using single balloon enteroscopy to safely remove the stone and foreign body from the bile duct. The foreign body was determined to be a fish bone by pathological examination and component analysis.

  10. Building stones can be of geoheritage significance

    Science.gov (United States)

    Brocx, Margaret; Semeniuk, Vic

    2017-04-01

    Building stones have generally been assigned values according to their cultural, aesthetic, and rarity significance, amongst other criteria, but they also may have geoheritage significance. This is akin to the geoheritage significance ascribed to minerals and fossils housed as ex situ specimens in museums. We proffer the notion that building stones can be of geoheritage value particularly where they comprise permanent buildings, they illustrate significant windows into the history of the Earth, and they can be visited as an ex situ museum locality (e.g., the "Blue Granite" of Iceland) for education as part of building-stone tours. For some rocks the quarries that supplied the building stone are no longer in existence and hence the building stones provide the only record of that type of material; for other rocks, the building stone may illustrate features in the lithology no longer present in the quarry itself (e.g., rare and large xenoliths). Building stones are particularly significant as they are often polished and manifest structures, fabrics, and textures not evident in outcrop. We illustrate here examples of building stone of geoheritage significance using Australian and International examples. Australian designated stones could include the "Sydney Sandstone" or "Victorian Bluestone". For international examples, there is the famous "Carrara Marble" in Italy and the widely known "Portland Limestone" from southern England, the latter having been utilized for St Pauls Cathedral in London and the UN building in New York City.

  11. A novel tool for automated evaluation of radiographic weld images

    International Nuclear Information System (INIS)

    Rajagopalan, C.; Venkatraman, B.; Jayakumar, T.; Kalyanasundaram, P.; Raj, B.

    2004-01-01

    Radiography is one of the oldest and the most widely used NDT method for the detection of volumetric defects in welds and castings. Once a radiograph of a weld or a casting or an assembly is taken, the radiographer examines the same. The task of the radiographer consists of identifying the defects and quantitatively evaluating the same based on codes and specifications. Radiographic interpretation primarily depends on the expertise of the individual radiographer. To overcome the subjectivity involved in human interpretation, it is thus desirable to develop a computer based automated system to aid in the interpretation of radiographs. Towards this goal, the authors have developed a flowchart chalking out the various stages involved. Typical weld images of tube to tubesheet weld joints were digitised using high resolution digitiser. The images were segmented and 52 invariant moments were computed to be used as features. The results of these are presented in this paper. Once the features (invariant moments) are extracted and ranked, a neural network classifier based on error back-propagation has to classify the (top ranking) features and evaluate the image for acceptance or rejection. (author)

  12. Radiographic diagnoses and treatment decisions on approximal caries

    International Nuclear Information System (INIS)

    Espelid, I.

    1987-01-01

    Mineral loss which represents a threshold value for radiographic diagnosis, cannot be defined exactly. For clinical use 10% mineral loss in the direction of the X-ray beam may constitute a border line lesion for radiographic detection, and caries lesions without cavitation seemed to be beyond this diagnostic threshold. The degree of caries estimated by using radiographs is fairly closely related to the depth of the tissue changes recorded in the prepared cavity. Radiographic examinations more often lead to underestimation than overestimation of the degree of caries. Radiographic caries diagnoses made at different degrees of penetration toward the pulp showed insignificant variations with respect to quality, but the observers were more confident of caries being present (used more strict criterion) when they scored caries in inner dentin. Consensus on diagnostic criteria and improved diagnostic quality are considerably more important to the quality of therapeutic decisions on approximal caries than viewing conditions and film density. A semi-radiopaque material in Class II fillings seems to offer advantages compared to amalgam in respect of the diagnosis of secondary caries and marginal defects. There is a danger that dentists will restore approximal caries lesions too early and before these can be diagnosed in dentin radiographically

  13. Radiographic study of the hepatomegaly

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Soo [Busan National University College of Medicine, Pusan (Korea, Republic of)

    1980-06-15

    The author studied, with emphasis on the various radiographic projections, the 99 cases of liver enlargement, which underwent the barium meal upper gastrointestinal examinations for the purpose of pursuit of significance of liver enlargement and, at the same time were confirmed by other clinical and pathological methods at Busan National University Hospital for about 2 years from November 1977 to September 1979. The following results were obtained: 1. The incidence of liver enlargement was 63.3% (62 cases) in the 5th decade, which was most prevalent, 18.2% (18 cases) in the 3rd decade, 15.2% (15 cases) in the group over 60, and 3.0% (3 cases) in the age group below 20. Male to female sex ratio was 2 : 1. 2. The causes of the liver enlargement confirmed by the final diagnosis are as follows: Primary hepatic cancer 39 cases (39.3%), liver cirrhosis 30 cases (30.3%), chronic hepatitis 12 cases (12.1%), cancer of the biliary tract 6 cases (6.1%), hepatic fluke 6 cases (6.1%), metastatic tumors 3 cases (3.0%), and hepatic congestion 3 cases (3.0%) 3. In the prone view, the displacement of the duodenal bulb appeared in 18 cases (18.2%). 4. In the routine radiographs, the displacement of the stomach to the left and the pressure indentation of the lesser curvature were noted in 69 cases (69.7%) out of 99 cases. 5.In the left lateral recumbent view, the pressure indentation of the anterior border of the gastric body was seen in 96 cases (97.0%) among the 99 cases, the straightening in 30 cases (27.3%), the marked depression in 30 cases (30.3%), the moderate in 27 cases (27.3%), the minimal in 9 cases (9.1%). 6. Comparing the incidences of the roentgen findings of the liver enlargement in the various projections respectively, the displacement of the duodenal bulb was noted in 18 cases (18.3%) in the prone position. The erect position revealed the displacement of the stomach to the left and the pressure indentation in 57 cases (57.6%), the prone position in 51 cases (51

  14. 77 FR 27245 - Big Stone National Wildlife Refuge, Big Stone and Lac Qui Parle Counties, MN

    Science.gov (United States)

    2012-05-09

    ... DEPARTMENT OF THE INTERIOR Fish and Wildlife Service [FWS-R3-R-2012-N069; FXRS1265030000S3-123-FF03R06000] Big Stone National Wildlife Refuge, Big Stone and Lac Qui Parle Counties, MN AGENCY: Fish and... plan (CCP) and environmental assessment (EA) for Big Stone National Wildlife Refuge (Refuge, NWR) for...

  15. Caries detection in dental radiographs

    International Nuclear Information System (INIS)

    Dunn, S.M.

    1987-01-01

    Caries, or the decay of teeth are difficult to automatically detect in dental radiographs because of the small area of the image that is occupied by the decay. Images of dental radiographs has distinct regions of homogeneous gray levels, and therefore naturally lead to a segmentation based automatic caries detection algorithm. This paper describes a method for caries detection based on a multiclass, area independent thresholding and segmenting scheme. This multiclass thresholding algorithm is an extension of the uniform error threshold, an area independent, distribution free thresholding method used for images of only two classes of objects. The authors first consider the problem of caries detection and the image features that characterize the presence of caries. Next, the uniform error threshold is reviewed, and the general multiclass uniform error threshold algorithm is presented. This algorithm is used to automatically detect caries in dental radiographs

  16. Interpretation and evaluation of radiograph

    International Nuclear Information System (INIS)

    Abdul Nassir Ibrahim; Azali Muhammad; Ab. Razak Hamzah; Abd. Aziz Mohamed; Mohamad Pauzi Ismail

    2008-01-01

    After digestion, the interpreter must interpreted and evaluate the image on film, usually many radiograph stuck in this step, if there is good density, so there are no problem. This is a final stage of radiography work and this work must be done by level two or three radiographer. This is a final stages before the radiographer give a result to their customer for further action. The good interpreter must know what kind of artifact, is this artifact are dangerous or not and others. In this chapter, the entire artifact that usually showed will be discussed briefly with the good illustration and picture to make the reader understand and know the type of artifact that exists.

  17. Industrial radiography on radiographic paper

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1977-11-01

    An investigation was performed to compare the quality of radiographic paper with that of X-ray film, after a review had been made of the rather scarce literature on the subject. The equipment used throughout the investigation is described, and characteristic curves for Agfa-Gevaert and Kodak papers exposed with different intensifying screens in the low and intermediate voltage range are reproduced. The relative speed, contrast and exposure latitude were computed from these curves. The quality of the radiographic image was checked on U/Al blocks and plates, Al and Fe blocks, and fiber-reinforced composites. Exposure charts for Al and Fe were made for various paper and screen combinations. Both the sharpness of the radiographic image as well as the influence of processing on speed and contrast were checked. Examples are given of the practical application of the paper for radiography of castings, weldings, solderings, assemblies, etc. (author)

  18. Use your good judgement - Radiographers' knowledge in image production work

    International Nuclear Information System (INIS)

    Larsson, W.; Lundberg, N.; Hillergard, K.

    2009-01-01

    It has been shown that the demand for radiography services has markedly increased and radiographers' work has become more complex as their role has changed. More specifically, it entails new activities, new ways of communicating and new responsibilities. This means that radiographers work in new ways and need new ways to learn. The knowledge needed in this learning process is still unexplored. The aim of this study is to identify and present how radiographers use knowledge in image production work using PACS. This is explored by studying how radiographers use their knowledge in practice. The study adopts a qualitative approach, using participant observation of and semi-structured interviews with radiographers at five Swedish hospitals. To identify properties of knowledge, Blackler's theory of knowledge components was applied. The results of this study show that radiographers use the knowledge components in different situations in their image production work. They use embrained knowledge in planning X-ray examinations and in viewing images. Encoded knowledge is required for the use of various kinds of documentation, such as manuals and protocols. Embodied knowledge is action-oriented and involves 'gut feelings'. The study also illustrates that radiographers use their knowledge at different levels as routine actors or as reflective actors, in a more static way or with a flexible attitude, more unreflectively or more as critical reflectors, and finally more as performing automatic action or problem-solving action. This study concludes that radiographers need more reflective actors in the image production process when working with PACS. The study also illustrates that radiographers need to be flexible in their work; there is little room for static work. In work they need to analyze images, it is not enough to 'check them off'; they cannot just read documents, you need to interpret them to optimize work performance. Overall, radiographers need to have a critical and

  19. The Value of Periapical Radiograph in the Diagnosis of Interproximal Caries

    International Nuclear Information System (INIS)

    KIm, Young Hee; Kang, Byung Chul

    2000-01-01

    To compare the diagnostic performance of clinical and radiologic examination for the interproximal caries on intraoral periapical radiographs and to evaluate the value of periapical radiographs. One hundred seven dental patients were examined clinically, with a mouth mirror and an explorer, by a dentist at the department of oral medicine, and the presence or absence of interproximal caries lesion was recorded. The patients were prescribed one or more dental periapical radiographs. Radiographs were assessed for the presence of interproximal caries by three radiologists independently. Two thousand sixty interproximal surfaces were included in this study. The diagnostic accuracies of clinical and radiologic examinations for interproximal caries were calculated. To assess the degree of agreement between clinical and radiologic examinations, Cohen's coefficient of agreement was computed. The specificity of clinical and radiologic examination was 0.991, 0.997 and the sensitivity was 0.279, 0.985 respectively. The diagnostic accuracy of radiologic examination was statistically significantly higher than that of clinical examination (P<0.05). Cohen's kappa value of clinical and radiologic examination was 0.335, 0.942 respectively. These results suggested that clinical examination show only fair agreement, whereas radiologic examination show perfect agreement. The diagnostic performance of the dental periapical radiographs on interproximal caries were higher than that of clinical examination, thus this study showed the validity of periapical radiographs for detecting interproximal caries lesion without bitewing radiograph.

  20. Digital image analysis of NDT radiographs

    International Nuclear Information System (INIS)

    Graeme, W.A. Jr.; Eizember, A.C.; Douglass, J.

    1989-01-01

    Prior to the introduction of Charge Coupled Device (CCD) detectors the majority of image analysis performed on NDT radiographic images was done visually in the analog domain. While some film digitization was being performed, the process was often unable to capture all the usable information on the radiograph or was too time consuming. CCD technology now provides a method to digitize radiographic film images without losing the useful information captured in the original radiograph in a timely process. Incorporating that technology into a complete digital radiographic workstation allows analog radiographic information to be processed, providing additional information to the radiographer. Once in the digital domain, that data can be stored, and fused with radioscopic and other forms of digital data. The result is more productive analysis and management of radiographic inspection data. The principal function of the NDT Scan IV digital radiography system is the digitization, enhancement and storage of radiographic images

  1. Radiographic investigations during medico-legal autopsies

    International Nuclear Information System (INIS)

    Bratzke, H.; Schneider, V.; Dietz, W.

    1982-01-01

    During the last 13 years (1968-1980), 427 radiographic examinations were carried out during the course of medico-legal autopsies at the Institute of Forensic Medicine at the Free University of Berlin. Important problems were the demonstration of retained foreign bodies resulting from shooting, stabbing or blunt trauma, bone injuries, identification, and the question of life in neonates. An historical survey is given and 12 cases with special forensic problems are illustrated and discussed, and further means of investigations are described. (orig.) [de

  2. General-purpose radiographic and fluoroscopic table

    International Nuclear Information System (INIS)

    Ishizaki, Noritaka

    1982-01-01

    A new series of diagnostic tables, Model DT-KEL, was developed for general-purpose radiographic and fluoroscopic systems. Through several investigations, the table was so constructed that the basic techniques be general radiography and GI examination, and other techniques be optionally added. The diagnostic tables involve the full series of the type for various purposes and are systematized with the surrounding equipment. A retractable mechanism of grids was adopted first for general use. The fine grids with a density of 57 lines per cm, which was adopted in KEL-2, reduced the X-ray doses by 16 percent. (author)

  3. Peri-acetabular radiolucent lines: inter- and intra-observer agreement on post-operative radiographs

    OpenAIRE

    Kneif, D.; Downing, M.; Ashcroft, G. P.; Gibson, P.; Knight, D.; Ledingham, W.; Hutchison, J.

    2005-01-01

    Peri-acetabular radiolucent lines (RLLs) seen on “early” post-operative radiographs have been identified as a potential predictor of long-term implant performance. This study examines the inter- and intra-observer variation encountered when assessing such radiographs. Four consultant orthopaedic surgeons assessed the presence, extent and width of RLLs in 220 radiographs performed on 50 patients taken one to two weeks, six weeks, six months and one year following surgery. Inter-observer agreem...

  4. Clinico-radiographic Studies on The Prevalent Distal Limb Affections in Working Equine at Luxor City

    OpenAIRE

    A. A.A. Abdel-Hady; M.A. Sadan; Asmaa A. Metwally; A.S. Soliman

    2017-01-01

    To illustrate the clinical and radiographic findings of some distal limbs affections in Ninety two animals (24 horses and 68 donkeys) which were admitted to Animal Care Hospital in Luxor. Each animal was subjected to thorough clinical and radiographic examination; the grade of lameness was recorded and the best radiographic views were taken.  Fifteen types of distal limb affections were evident. The most prevalent affections in donkeys were high and low ring bone (29.35%) and hoof abscess ( 9...

  5. Limitations of radiographs in evaluating non-displaced osteochondral lesions of the talus

    Energy Technology Data Exchange (ETDEWEB)

    Dheer, Sachin [Department of Radiology, Kennedy Health System, Cherry Hill, NJ (United States); Khan, Mustafa [University of Toledo Medical Center, Department of Orthopedic Surgery, Toledo, OH (United States); Zoga, Adam C.; Morrison, William B. [Thomas Jefferson University Hospital, Department of Radiology, Philadelphia, PA (United States)

    2012-04-15

    To evaluate what limitations, if any, radiographs have in detecting and characterizing the morphology of non-displaced OCLTs (size, cystic change, fragmentation, and avascular necrosis [AVN]). Thirty-three OCLTs in 32 patients were reviewed in consensus by a board-certified, fellowship-trained musculoskeletal radiologist and orthopedic surgeon, on radiographs and MRI examinations performed within 15 days of one another. Location, dimensions, and characteristics of the OCLT (fragmentation, bone marrow edema, cystic change, and necrosis) were documented on the radiographs and MRI examinations. There was an average of 7.5 days (range: 1-15 days) between the MRIs and radiographs. Eighteen (55%) medial and 15 (45%) lateral OCLTs were found; none was displaced. OCLTs were categorized into three groups: Group 1 - initially diagnosed with radiographs (4/33; 12%), Group 2 - diagnosed with radiographs only after MRI correlation (20/33; 61%), and Group 3 - not identifiable on radiographs despite MRI correlation (9/33; 27%). The dimensions of all of the lesions in Groups 1 and 2 were underestimated on radiographs. Only 1 of the 4 (25%) lesions in Group 1 and 1 of the 20 (5%) lesions in Group 2 could be measured in the anteroposterior (AP) dimension (using a lateral radiograph). The most common radiographic appearance of non-displaced OCLTs was an ''ill-defined'' lucency at the talar dome (20/33; 61%). Across all three groups, fragmentation, cystic change, and AVN were radiographically apparent in 3/10 (30%), 4/19 (21%), and 1/6 (17%) cases respectively. Compared with MRI, radiographs are limited in their evaluation of the size (particularly the AP dimension) and characteristics (fragmentation, cystic change, and AVN) of non-displaced OCLTs. The most common appearance of non-displaced OCLTs is an ''ill-defined'' lucency at the talar dome. When this appearance is also considered, the estimated retrospective sensitivity of radiographs

  6. Limitations of radiographs in evaluating non-displaced osteochondral lesions of the talus

    International Nuclear Information System (INIS)

    Dheer, Sachin; Khan, Mustafa; Zoga, Adam C.; Morrison, William B.

    2012-01-01

    To evaluate what limitations, if any, radiographs have in detecting and characterizing the morphology of non-displaced OCLTs (size, cystic change, fragmentation, and avascular necrosis [AVN]). Thirty-three OCLTs in 32 patients were reviewed in consensus by a board-certified, fellowship-trained musculoskeletal radiologist and orthopedic surgeon, on radiographs and MRI examinations performed within 15 days of one another. Location, dimensions, and characteristics of the OCLT (fragmentation, bone marrow edema, cystic change, and necrosis) were documented on the radiographs and MRI examinations. There was an average of 7.5 days (range: 1-15 days) between the MRIs and radiographs. Eighteen (55%) medial and 15 (45%) lateral OCLTs were found; none was displaced. OCLTs were categorized into three groups: Group 1 - initially diagnosed with radiographs (4/33; 12%), Group 2 - diagnosed with radiographs only after MRI correlation (20/33; 61%), and Group 3 - not identifiable on radiographs despite MRI correlation (9/33; 27%). The dimensions of all of the lesions in Groups 1 and 2 were underestimated on radiographs. Only 1 of the 4 (25%) lesions in Group 1 and 1 of the 20 (5%) lesions in Group 2 could be measured in the anteroposterior (AP) dimension (using a lateral radiograph). The most common radiographic appearance of non-displaced OCLTs was an ''ill-defined'' lucency at the talar dome (20/33; 61%). Across all three groups, fragmentation, cystic change, and AVN were radiographically apparent in 3/10 (30%), 4/19 (21%), and 1/6 (17%) cases respectively. Compared with MRI, radiographs are limited in their evaluation of the size (particularly the AP dimension) and characteristics (fragmentation, cystic change, and AVN) of non-displaced OCLTs. The most common appearance of non-displaced OCLTs is an ''ill-defined'' lucency at the talar dome. When this appearance is also considered, the estimated retrospective sensitivity of radiographs improves considerably. (orig.)

  7. Primary anterior vaginal wall pure ammonium acid urate stone. Case report

    Directory of Open Access Journals (Sweden)

    Sherif M. Khattab

    2013-06-01

    Full Text Available Vaginal stones are extremely rare and are classified as primary and secondary. A 45 year-old female presented with an unexplained dyspareunia and vaginal discomfort for 2 years unresponsive to traditional treatment. Vaginal examination revealed no prolapse or vaginal fistula. Digital examination revealed multiple small rounded firm to hard or tender masses varying in size from 0.5 to 1.5 cm anterior to the vagina. Patient was treated with midline anterior vaginal wall incision with the extraction of eight smooth surfaced stones with uneventful postoperative course. Stone analysis revealed that they were composed of pure ammonium acid urate (AU. We recommend that for any patient with unexplained dyspareunia or vaginal discomfort that has proved to be unresponsive to traditional treatment, the possibility of anterior vaginal wall stones should be kept in mind.

  8. PACS influence the radiographer's work

    International Nuclear Information System (INIS)

    Fridell, Kent; Aspelin, Peter; Edgren, Lars; Lindskoeld, Lars; Lundberg, Nina

    2009-01-01

    Radiological departments are changing rapidly due to the implementation of digital images and PACS (Picture Archiving and Communication Systems). The introduction of new technology seems to dissolve boundaries between the professions in the work environment where the technology is introduced. This process tends to change the organization and its routines. The aim of this qualitative study is to explore changes in radiographers' work with regard to skills, work practice and technology. The study used open-ended interviews to explore the radiographers' perceptions of such changes, and to identify problems and solutions pertaining to work practice. Inspiration is taken from grounded theory to explain the changes in work that were found. Respondents were selected from a total of 133 potential participants as a theoretical or purposive sample. The changing trends within the professional role indicated that radiographers, as image producers, shifted their focus from the ability to set the optimal exposure parameters in order to obtain the optimal image for diagnosis to become expert in exposure parameters, projection techniques and diagnostic practice, having multifaceted skills, as being the jack of all trades. When implementing PACS there was an obvious change in image production. At the start there were visions of new routines, and therefore the radiographers became early adopters to the new technology; in practice the organization was stacked in old routines, as the routines were inflexible and PACS work was pushed into old work routines. Although inflexible, this does not mean that they cannot change, and obviously in 2006 new routines had been implemented making it possible for the radiographers in finding new ways for collaborating with colleagues. The new technology immediately created a vision of improved service to the clinicians. In order to optimize the service the radiographers developed an insight into the need for a more comprehensive change in work using

  9. Analysis of archaeological precious stones from Slovenia

    Energy Technology Data Exchange (ETDEWEB)

    Šmit, Ž. [Facully of Mathematics and Physics, University of Ljubljana (Slovenia); Fajfar, H. [Jožef Stefan Institute, Ljubljana (Slovenia); Jeršsek, M. [Slovenian Museum of Natural History, Ljubljana (Slovenia); Knific, T. [National Museum of Slovenia, Ljubljana (Slovenia); Kržic, A. [Higher Vocational Centre, Sezana (Slovenia); Lux, J. [Institute for the Protection of Cultural Heritage of Slovenia, Ljubljana (Slovenia)

    2013-07-01

    Full text: Precious stones have been attractive pieces of jewelry since ancient times. However, due to the limited sources of origin, the quality of applied items mainly depended on long-range commercial relations, but also on fashion. In Antiquity and Late Antiquity, stones much used and sought for were emeralds and garnets. In Slovenia, emeralds are typically related to the early Roman period and are incorporated in the finds of gold jewelry from the graves. Emerald is generally beryl colored by admixture of chromium, though green colors can also be due to admixtures of iron or vanadium. Garnets were increasingly used by various nations of the People Migration period, and mounted in gilded silver or gold objects by 'cloisonne' or 'en cabochon' techniques. In Slovenia, numerous jewelry items containing garnets were found in the graves and in post-Roman fortified settlements. Geologically, according to the admixtures of metal ions, the garnets are divided into several species, while the most common among archaeological finds are almandines and pyropes and their intermediate types. It is also common to divide garnets into five groups, the first two originating from India, the third from Ceylon and the fifth from Czech Republic. The measurements involved presumed emeralds from Roman jewelry finds in Slovenia and comparative samples of beryl from Siberia and Habachtal in Austria. The analysis determined the coloring ions and showed relations between particular stones. For garnets, ten samples from brooches, earrings and rings were selected for the analysis on the basis of previous micro Raman examination. The analysis was performed by a combined PIXE-PIGE technique using proton beam in air. The light elements of Na, Mg, AI were determined according to the emitted gamma rays, while X-rays were used for the elements heavier than silicon. Two X-ray spectra were measured in each measuring point, soft and hard X-ray; the latter was obtained using an

  10. Analysis of archaeological precious stones from Slovenia

    International Nuclear Information System (INIS)

    Šmit, Ž.; Fajfar, H.; Jeršsek, M.; Knific, T.; Kržic, A.; Lux, J.

    2013-01-01

    Full text: Precious stones have been attractive pieces of jewelry since ancient times. However, due to the limited sources of origin, the quality of applied items mainly depended on long-range commercial relations, but also on fashion. In Antiquity and Late Antiquity, stones much used and sought for were emeralds and garnets. In Slovenia, emeralds are typically related to the early Roman period and are incorporated in the finds of gold jewelry from the graves. Emerald is generally beryl colored by admixture of chromium, though green colors can also be due to admixtures of iron or vanadium. Garnets were increasingly used by various nations of the People Migration period, and mounted in gilded silver or gold objects by 'cloisonne' or 'en cabochon' techniques. In Slovenia, numerous jewelry items containing garnets were found in the graves and in post-Roman fortified settlements. Geologically, according to the admixtures of metal ions, the garnets are divided into several species, while the most common among archaeological finds are almandines and pyropes and their intermediate types. It is also common to divide garnets into five groups, the first two originating from India, the third from Ceylon and the fifth from Czech Republic. The measurements involved presumed emeralds from Roman jewelry finds in Slovenia and comparative samples of beryl from Siberia and Habachtal in Austria. The analysis determined the coloring ions and showed relations between particular stones. For garnets, ten samples from brooches, earrings and rings were selected for the analysis on the basis of previous micro Raman examination. The analysis was performed by a combined PIXE-PIGE technique using proton beam in air. The light elements of Na, Mg, AI were determined according to the emitted gamma rays, while X-rays were used for the elements heavier than silicon. Two X-ray spectra were measured in each measuring point, soft and hard X-ray; the latter was obtained using an

  11. A Lion of a Stone

    Science.gov (United States)

    2004-01-01

    This approximate true-color image of the rock called 'Lion Stone' was acquired by the Mars Exploration Rover Opportunity's panoramic camera on sol 104 (May 9, 2004). The rock stands about 10 centimeters tall (about 4 inches) and is about 30 centimeters long (12 inches). Plans for the coming sols include investigating the rock with the spectrometers on the rover's instrument arm. This image was generated using the camera's L2 (750-nanometer), L5 (530-nanometer) and L6 (480-nanometer) filters.

  12. Do You Have Symptoms of a Kidney Stone?

    Science.gov (United States)

    ... Or, the stone will be removed with treatment. Dogs, Cats, and Kidney Stones Humans aren't the only ones affected by kidney and bladder stones. Dogs, cats, and other animals can also have kidney ...

  13. Radiographic, high detail radiographic, microangiographic and histological findings of the distal portion of the tarsus in weanling young and adult horses

    International Nuclear Information System (INIS)

    Laverty, S.; Stover, S.M.; Bélanger, D.; O'Brien, T.R.; Pool, R.R.; Pascoe, J.R.; Taylor, K.; Harrington, T.

    1991-01-01

    Clinical radiographic (LM and D35L-P1MO reviews), high detail radiographic, microangiographic and histological findings of distal portion of the tarsus of 16 horses (five weanling, four young and six adult), without known clinical histories, were evaluated to determine the sensitivity of clinical radiographs for the detection of abnormalities in the distal tarsus and the prevalence of abnormalities in this population. Clinical radiographic and high detail radiographic abnormalities were observed in at least 30 per cent of the tarsi examined. Statistical agreement between observations from clinical radiographs and corresponding post mortem high detail radiographs was not good for subchondral bone plate irregularities and joint margin changes. Three patterns of sclerosis of the medullary spongiosa were visualized on high detail radiographs; thickening of the subchondral bone plate was seen commonly in the weaning group,, whereas arching and bridging patterns were more prevalent in the young and adult groups. Bone production on the dorsal cortex of the central and third tarsal bones did not increase with age. Abnormalities in vascular perfusion and articular cartilage histology were observed in association with subchondral bone plate irregularities and focal regions of osteopenia observed on high detail radiographs

  14. Population-based estimate of urinary stones from Ballabgarh, northern India.

    Science.gov (United States)

    Lohiya, Ayush; Kant, Shashi; Kapil, Arti; Gupta, Sanjeev Kumar; Misra, Puneet; Rai, Sanjay K

    2017-01-01

    Stones in the urinary tract are a common condition but there is paucity of data on their population-based estimates in India. We describe our findings of the burden of urinary stones during a cross-sectional study with another primary goal. We conducted the study at Ballabgarh Health and Demographic Surveillance System, Haryana, among residents aged 18 years or above. We used simple random sampling to enrol participants. Self-reported history of urinary stones was elicited through an interview schedule. Results of the descriptive analysis were described as proportions with 95% confidence intervals (CI) or as mean wherever applicable. Bivariate analysis was done using t-test and chi-square test as applicable. The response rate for our study was 86.6%; lifetime prevalence (95% CI) of urinary stones was 7.9% (5.7, 10.8). In a majority of participants, urinary stones were diagnosed at an age of 20-40 years (55.9%), mostly by an ultrasonography examination (94.1%). A high burden of urinary stones is indicated in the working-age population in northern India at the community level. Untreated urinary stones can lead to an acute emergency (colic) or may have long-term adverse consequences, e.g. hydronephrosis, which have implications for the healthcare delivery system.

  15. Evidence suggesting a genetic contribution to kidney stone in northeastern Thai population.

    Science.gov (United States)

    Sritippayawan, Suchai; Borvornpadungkitti, Sombat; Paemanee, Atchara; Predanon, Chagkrapan; Susaengrat, Wattanachai; Chuawattana, Duangporn; Sawasdee, Nunghathai; Nakjang, Sirintra; Pongtepaditep, Suttikarn; Nettuwakul, Choochai; Rungroj, Nanyawan; Vasuvattakul, Somkiat; Malasit, Prida; Yenchitsomanus, Pa-thai

    2009-06-01

    Genetic factor may play a role in the pathogenesis of kidney stone that is found in the northeastern (NE) Thai population. Herein, we report initial evidence suggesting genetic contribution to the disease in this population. We examined 1,034 subjects including 135 patients with kidney stone, 551 family members, and 348 villagers by radiography of kidney-ureter-bladder (KUB) and other methods, and also analyzed stones removed by surgical operations. One hundred and sixteen of 551 family members (21.05%) and 23 of the 348 villagers (6.61%) were affected with kidney stone. The relative risk (lambda(R)) of the disease among family members was 3.18. Calcium stones (whewellite, dahllite, and weddellite) were observed in about 88% of stones analyzed. Our data indicate familial aggregation of kidney stone in this population supporting that genetic factor should play some role in its pathogenesis. Genetic and genomic studies will be conducted to identify the genes associated with the disease.

  16. Diabetes in relation to biliary tract cancer and stones: a population-based study in Shanghai, China

    Science.gov (United States)

    Shebl, F M; Andreotti, G; Rashid, A; Gao, Y-T; Yu, K; Shen, M-C; Wang, B-S; Li, Q; Han, T-Q; Zhang, B-H; Fraumeni, J F; Hsing, A W

    2010-01-01

    Background: Biliary tract cancers are rare but fatal malignancies. Diabetes has been related to biliary stones, but its association with biliary tract cancers is less conclusive. Methods: In a population-based case–control study of 627 cancers, 1037 stones, and 959 controls in Shanghai, China, we examined the association between diabetes and the risks of biliary tract cancer and stones, as well as the effect of potential mediating factors, including serum lipids and biliary stones (for cancer), contributing to the causal pathway from diabetes to biliary diseases. Results: Independent of body mass index (BMI), diabetes was significantly associated with gallbladder cancer and biliary stones ((odds ratio (OR) (95% confidence interval)=2.6 (1.5–4.7) and 2.0 (1.2–3.3), respectively). Biliary stones and low serum levels of high-density lipoprotein (HDL) were significant mediators of the diabetes effect on gallbladder cancer risk, accounting for 60 and 17% of the diabetes effect, respectively. High-density lipoprotein was also a significant mediator of the diabetes effect on biliary stones, accounting for 18% of the diabetes effect. Conclusions: Independent of BMI, diabetes is a risk factor for gallbladder cancer, but its effect is mediated in part by biliary stones and serum HDL levels, suggesting that gallbladder cancer risk may be reduced by controlling diabetes, stones, and HDL levels. PMID:20517308

  17. Use-Wear Patterns on Wild Macaque Stone Tools Reveal Their Behavioural History

    OpenAIRE

    Haslam, Michael; Gumert, Michael D.; Biro, Dora; Carvalho, Susana; Malaivijitnond, Suchinda

    2013-01-01

    Burmese long-tailed macaques (Macaca fascicularis aurea) are one of a limited number of wild animal species to use stone tools, with their tool use focused on pounding shelled marine invertebrates foraged from intertidal habitats. These monkeys exhibit two main styles of tool use: axe hammering of oysters, and pound hammering of unattached encased foods. In this study, we examined macroscopic use-wear patterns on a sample of 60 wild macaque stone tools from Piak Nam Yai Island, Thailand, that...

  18. Radiographic and ultrasonographic characteristics of ventral abdominal hernia in pigeons (Columba livia).

    Science.gov (United States)

    Amer, Mohammed S; Hassan, Elham A; Torad, Faisal A

    2018-02-20

    Five female egg-laying pigeons presented with painless, reducible, ventral abdominal swellings located between the keel and the pubis, or close to the cloaca. Based on clinical, radiographic, and ultrasonographic examination, these pigeons were diagnosed with ventral abdominal hernia requiring surgical interference. Reduction was successfully performed under general anesthesia. Radiographic and ultrasonographic examinations were beneficial for confirming the diagnosis and visualizing the hernial content for surgical planning. Lateral radiographs were more helpful than ventrodorsal radiographs for identification of the hernial content and its continuation with the abdominal muscles. Ultrasonographic examination offered a non-invasive diagnostic tool that allowed for the differentiation of hernia from other abdominal swellings. In addition, it played a beneficial role in identification of the hernial content and follow up after surgical interference. In conclusion, radiographic and ultrasonographic examinations were beneficial in the diagnosis, surgical planning, and follow up after surgical interference of ventral abdominal hernia in pigeons.

  19. Radiographer's impact on improving clinical decision-making, patient care and patient diagnosis: a pilot study

    International Nuclear Information System (INIS)

    Lam, Daniel; Egan, Ingrid; Baird, Marilyn

    2004-01-01

    This pilot study attempts to quantify the benefits of a documented radiographic clinical history through the use of the clinical history template form designed by Egan and Baird. Six radiographers completed the clinical history template for 40 patients and four radiologists included the recorded information as part of their reporting process. A focus discussion group was held between the radiographers to ascertain the level of satisfaction and benefits encountered with the use of the template form. A questionnaire was designed for the radiologists to complete regarding the usefulness of the template form with respect to the radiological reporting process. Results/Discussion: 15 cases for which the form was used demonstrated a direct benefit in respect to improved radiographic clinical decision-making. Radiographers agreed the template form aided the establishment of a stronger radiographer-patient relationship during the radiographic examination. Two radiologists agreed the form aided in establishing a radiological diagnosis and suggested the form be implemented as part of the standard departmental protocol. Despite the small sample size, there is evidence the form aided radiographic decision-making and assisted in the establishment of an accurate radiological diagnosis. The overall consensus amongst radiographers was that it enhanced radiographer-patient communication and improved the level of patient care. Copyright (2004) Australian Institute of Radiography

  20. Contribution of stone size to chronic kidney disease in kidney stone formers.

    Science.gov (United States)

    Ahmadi, Farrokhlagha; Etemadi, Samira Motedayen; Lessan-Pezeshki, Mahbob; Mahdavi-Mazdeh, Mitra; Ayati, Mohsen; Mir, Alireza; Yazdi, Hadi Rokni

    2015-01-01

    To determine whether stone burden correlates with the degree of chronic kidney disease in kidney stone formers. A total of 97 extracorporeal shockwave lithotripsy candidates aged 18 years and older were included. Size, number and location of the kidney stones, along with cumulative stone size, defined as the sum of diameters of all stones) were determined. Estimated glomerular filtration rate was determined using the Chronic Kidney Disease Epidemiology Collaboration cystatin C/creatinine equation, and chronic kidney disease was defined as estimated glomerular filtration rate chronic kidney disease. The relationship persisted even after adjustment for age, sex, body mass index, C-reactive protein, fasting plasma glucose, thyroid stimulating hormone, presence of microalbuminuria, history of renal calculi, history of extracorporeal shockwave lithotripsy, number and location of the stones (odds ratio 1.24, 95% confidence interval 1.02-1.52). The same was not observed for individuals with a cumulative stone size ≥ 20 mm. In kidney stone formers with a cumulative stone size up to 20 mm, estimated glomerular filtration rate linearly declines with increasing cumulative stone size. Additionally, cumulative stone size is an independent predictor of chronic kidney disease in this group of patients. © 2014 The Japanese Urological Association.

  1. Percutaneous suprapubic stone extraction for posterior urethral stones in children: efficacy and safety.

    Science.gov (United States)

    Safwat, Ahmed S; Hameed, Diaa A; Elgammal, Mohamed A; Abdelsalam, Yasser M; Abolyosr, Ahmad

    2013-08-01

    To evaluate the safety and efficacy of percutaneous suprapubic stone extraction (PSPSE) for pediatric posterior urethral stones. Between July 2007 and June 2010, 54 boys presenting with acute urinary retention due to posterior urethral stones underwent PSPSE. Patients were a mean age of 66.4 months (range, 8-180 months). The stone size was 0.7-1.9 cm. Patients were placed under general anesthesia, and a 7F urethroscope was used to pushback the stone to the bladder. A 3-mm suprapubic puncture with a scalpel was performed, followed by insertion of a straight narrow hemostat through the puncture aided with cystoscopic guidance. The stone was grasped with the hemostat in its narrowest diameter and was extracted percutaneously or crushed if friable. The suprapubic puncture was closed with a single 4-0 Vicryl (Ethicon) suture. Intact stone retrieval was achieved in 45 patients, and the stone was crushed into minute fragments in 9 patients. Intraperitoneal extravasation developed in 1 patient that required open surgical intervention. Mean operative time was 22 minutes. Patients were monitored for up to 17 months, with complete resolution of symptoms and stone clearance. PSPSE provides a minimally invasive approach for the extraction of urethral and bladder stones in the pediatric population. The use of a straight hemostat for suprapubic stone extraction or crushing is a good alternative to suprapubic tract dilation, with minimal morbidity. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Metabolic Characteristics and Risks Associated with Stone Recurrence in Korean Young Adult Stone Patients.

    Science.gov (United States)

    Kang, Ho Won; Seo, Sung Pil; Kim, Won Tae; Kim, Yong-June; Yun, Seok-Joong; Kim, Wun-Jae; Lee, Sang-Cheol

    2017-08-01

    The aim of this study was to assess the metabolic characteristics and risks of stone recurrence in young adult stone patients in Korea. The medical records of 1532 patients presenting with renal or ureteric stones at our stone clinic between 1994 and 2015 were retrospectively reviewed. Patients were grouped according to age (young adult, 18-29 years; intermediate onset, 30-59 years; old age, ≥60 years) at first presentation, and measurements of clinicometabolic characteristics and risks of stone recurrence were compared. Overall, excretion of urinary stone-forming substances was highest in the intermediate onset group, followed by the young adult and old age groups. Importantly, excretion of urinary citrate was lowest in the young adult group. Kaplan-Meier analyses identified a significant difference between the three age groups in terms of stone recurrence (log rank test, p adult stone patients. Younger age (18-29 years) at first stone presentation was a significant risk factor for stone recurrence, and urinary citrate excretion was an independent risk factor affecting recurrence in this group. Metabolic evaluation and potassium citrate therapy should be considered for young adult stone patients to prevent recurrence.

  3. A Boy with a Large Bladder Stone

    Directory of Open Access Journals (Sweden)

    Kuo-Shen Chow

    2008-08-01

    Full Text Available Despite the frequent association of urinary tract infection with vesicoureteral reflux and urinary calculi, since vesicouretal reflux is induced by bladder stones, the coexistence of vesicoureteral reflux and bladder stones is rare. Because of its occurrence in children belonging to poor socioeconomic groups, it is believed to be a deficiency disorder. Most cases of bladder stones occur between the ages of 2 and 5 years. Common clinical presentations of bladder stones include urinary dribbling and enuresis, frequency of micturition, pain during micturition, pelvic pain and hematuria. We report the occurrence of a large bladder stone in a boy, who experienced intermittent lower abdominal pain and urinary incontinence, both during the day and at night. He had been diagnosed with enuresis and treated in pediatric clinics for 1 year. Delayed diagnosis resulted in bladder stone formation. The stone was larger than 2.5 cm and open vesicolithotomy was therefore selected as the best and safest treatment choice. His symptoms disappeared after surgery. Thorough metabolic and environmental evaluations of such cases are required on an individual basis. Bladder stones should be considered as a possible diagnosis in children presenting with urinary incontinence.

  4. Sculpture: Stone Shapes, Art: 6683.08.

    Science.gov (United States)

    Dubocq, Edward R.

    This elective course for grades 7-12 was created with a three fold purpose: 1) to create in the student an awareness of the effect of sculptural forms on his environment; 2) to introduce the student to an appreciation of stone sculpture; and 3) to further enhance the artistic abilities of the student through sculpting in stone. Course content…

  5. Frequency of stone clearance after extracorporeal shockwave ...

    African Journals Online (AJOL)

    Objective: To determine the rate of stone clearance after extracorporeal shockwave lithotripsy (ESWL) for renal stones in adult patients with renal insufficiency. Subjects and methods: This is a cross-sectional descriptive study of 117 adult patients who underwent ESWL. The indications for ESWL were determined by the ...

  6. Stone Formation in the Infected Pediatric Enterocystoplasty

    NARCIS (Netherlands)

    R.B. Mathoera (Rejiv)

    2003-01-01

    markdownabstract__Abstract__ Proteus mirabilis is one of the most frequent bacterial agents that can induce infection stone formation by urease production. In recent years the influence of Proteus mirabilis on stone formation in enterocystoplasties has been primarily related to the presence of

  7. Radiographic testing in concrete structures

    International Nuclear Information System (INIS)

    Oliveira, D. de

    1987-01-01

    The radiographic testing done in concrete structures is used to analyse the homogeneity, position and corrosion of armatures and to detect discontinuity in the concrete such as: gaps, cracks and segregations. This work develops a Image quality Indicator (IQI) with an adequated sensibility to detect discontinuites based on BS4408 norm. (E.G.) [pt

  8. Effect of stone coverage on soil erosion

    Science.gov (United States)

    Jomaa, S.; Barry, D. A.; Heng, B. P.; Brovelli, A.; Sander, G. C.; Parlange, J.

    2010-12-01

    Soil surface coverage has a significant impact on water infiltration, runoff and soil erosion yields. In particular, surface stones protect the soils from raindrop detachment, they retard the overland flow therefore decreasing its sediment transport capacity, and they prevent surface sealing. Several physical and environmental factors control to what extent stones on the soil surface modify the erosion rates and the related hydrological response. Among the most important factors are the moisture content of the topsoil, stone size, emplacement, coverage density and soil texture. Owing to the different inter-related processes, there is ambiguity concerning the quantitative effect of stones, and process-based understanding is limited. Experiments were performed (i) to quantify how stone features affect sediment yields, (ii) to understand the local effect of isolated surface stones, that is, the changes of the soil particle size distribution in the vicinity of a stone and (iii) to determine how stones attenuate the development of surface sealing and in turn how this affects the local infiltration rate. A series of experiments using the EPFL 6-m × 2-m erosion flume were conducted at different rainfall intensities (28 and 74 mm h-1) and stone coverage (20 and 40%). The total sediment concentration, the concentration of the individual size classes and the flow discharge were measured. In order to analyze the measurements, the Hairsine and Rose (HR) erosion model was adapted to account for the shielding effect of the stone cover. This was done by suitably adjusting the parameters based on the area not covered by stones. It was found that the modified HR model predictions agreed well with the measured sediment concentrations especially for the long time behavior. Changes in the bulk density of the topsoil due to raindrop-induced compaction with and without stone protection revealed that the stones protect the upper soil surface against the structural seals resulting in

  9. Instrumental neutron activation analysis of kidney stones

    International Nuclear Information System (INIS)

    Sarmani, S.; Kuan, L.L.; Bakar, M.A.A.

    1990-01-01

    Kidney stone samples of the types calcium oxalate, uric acid, and xanthine were analyzed for their elemental contents by neutron activation analysis to study both the elemental correlation and influence of element on stone precipitation processes. Elements, such as Al, Au, Br, Ca, Cl, Co, Cr, Fe,H, I, K, Mg, Na, Sb, Se, Sr, and Zn, were determined quantitatively. Calcium oxalate stones contained higher concentration of all the elements analyzed compared to uric acid or xanthine stones. The concentrations of Cl, Fe, K, Na, Sr, and Zn were relatively higher than Au, Co, Cr, and Sb. A positive correlation exists between Ca and Zn, whereas a negative correlation exists between Sr and Ca. Zinc may play an important role in the formation of calcium oxalate stone

  10. Extracorporeal Shockwave Lithotripsy of Primary Intrahepatic Stones

    Science.gov (United States)

    Kim, Myung Hwan; Lee, Sung Koo; Min, Young Il; Lee, Mun Gyu; Sung, Kyu Bo; Cho, Kyung Sik; Lee, Sung Gyu; Min, Pyung Chul

    1992-01-01

    Extracorporeal shockwave lithothripsy (ESWL) was performed in intrahepatic stone patients (n = 18) by Dornier MPL 9,000 with ultrasound guidance. The patients had T-tube (n = 9) or percutaneous transhepatic biliary drainge tube (n = 9). Average treatment session was four and shock-wave numbers were in the range of 3,064 to 12,000 (average 6,288 shocks). Intrahepatic stones were removed completely in 16 patients over a 3 month period by ESWL and combined stone extraction maneuver such as cholangioscopic or interventional radiologic method. Extracorporeal shockwave lithothripsy was very helpful in facilitating extraction of stones in unfavorable locations or located above the severe stricture. In summary, extracorporeal Shockwave lithotripsy, followed by percutaneous stone extraction, will provide an improvement in the success rate and duration of treatment required for complete removal of primary hepatolithiasis. PMID:1477027

  11. Factors affecting stone-free rate and complications of percutaneous nephrolithotomy for treatment of staghorn stone.

    Science.gov (United States)

    el-Nahas, Ahmed R; Eraky, Ibrahim; Shokeir, Ahmed A; Shoma, Ahmed M; el-Assmy, Ahmed M; el-Tabey, Nasr A; Soliman, Shady; Elshal, Ahmed M; el-Kappany, Hamdy A; el-Kenawy, Mahmoud R

    2012-06-01

    To determine factors affecting the stone-free rate and complications of percutaneous nephrolithotomy (PNL) for treatment of staghorn stones. The computerized database of patients who underwent PNL for treatment of staghorn stones between January 2003 and January 2011 was reviewed. All perioperative complications were recorded and classified according to modified Clavien classification system. The stone-free rate was evaluated with low-dose noncontrast computed tomography (CT). Univariate and multivariate statistical analyses were performed to determine factors affecting stone-free and complication rates. The study included 241 patients (125 male and 116 female) with a mean age of 48.7 ±14.3 years. All patients underwent 251 PNL (10 patients had bilateral stones). The stone-free rate of PNL monotherapy was 56% (142 procedures). At 3 months, the stone-free rate increased to 73% (183 kidneys) after shock wave lithotripsy. Independent risk factors for residual stones were complete staghorn stone and presence of secondary calyceal stones (relative risks were 2.2 and 3.1, respectively). The complication rate was 27% (68 PNL). Independent risk factors for development of complications were performance of the procedure by urologists other than experienced endourologist and positive preoperative urine culture (relative risks were 2.2 and 2.1, respectively). Factors affecting the incidence of residual stones after PNL are complete staghorn stones and the presence of secondary calyceal stones. Complications are significantly high if PNL is not performed by an experienced endourologist or if preoperative urine culture is positive. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Radiographic anatomy of the equine thorax as a basis for radiological interpretation

    International Nuclear Information System (INIS)

    Sanderson, G.N.; O'Callaghan, M.W.

    1983-01-01

    This article describes the gross radiographic anatomy of the equine thorax observed on the lateral radiographic projection. The descriptions presented were derived from a retrospective study of a large number of thoracic radiographs of cases referred to the Massey University clinic in conjunction with research studies in bronchography, angiography and in vitro contrast techniques. The characteristics of the thoracic bony structures, the vasculature, and the airways are examined separately; followed by a discussion of the relative contribution of the various structures to the overall thoracic radiograph

  13. Radiographic changes in the condyle of the temporomandibular joint in psoriatic arthritis

    International Nuclear Information System (INIS)

    Koenoenen, M.; Helsinki Univ.

    1987-01-01

    One hundred and ten patients with psoriatic arthritis (PA) and 100 matched control patients were examined by using orthopantomography to discover radiographic changes in the condyle of the temporomandibular joint (TMJ). 31% of the PA patients and 13% of the control patients had radiographic changes in the condyle of the TMJ. The most common radiographic finding in PA patients was unilateral erosion of the condyle. Of the radiographic changes in the PA group, cortical erosions correlated negatively with age, whereas osteophytes correlated positively with the duration of PA. (orig.)

  14. Optimum nutrition for kidney stone disease.

    Science.gov (United States)

    Heilberg, Ita P; Goldfarb, David S

    2013-03-01

    We summarize the data regarding the associations of individual dietary components with kidney stones and the effects on 24-hour urinary profiles. The therapeutic recommendations for stone prevention that result from these studies are applied where possible to stones of specific composition. Idiopathic calcium oxalate stone-formers are advised to reduce ingestion of animal protein, oxalate, and sodium while maintaining intake of 800 to 1200 mg of calcium and increasing consumption of citrate and potassium. There are few data regarding dietary therapy of calcium phosphate stones. Whether the inhibitory effect of citrate sufficiently counteracts increasing urine pH to justify more intake of potassium and citrate is not clear. Reduction of sodium intake to decrease urinary calcium excretion would also be expected to decrease calcium phosphate stone recurrence. Conversely, the most important urine variable in the causation of uric acid stones is low urine pH, linked to insulin resistance as a component of obesity and the metabolic syndrome. The mainstay of therapy is weight loss and urinary alkalinization provided by a more vegetarian diet. Reduction in animal protein intake will reduce purine ingestion and uric acid excretion. For cystine stones, restriction of animal protein is associated with reduction in intake of the cystine precursor methionine as well as cystine. Reduction of urine sodium results in less urine cystine. Ingestion of vegetables high in organic anion content, such as citrate and malate, should be associated with higher urine pH and fewer stones because the amino acid cystine is soluble in more alkaline urine. Because of their infectious origin, diet has no definitive role for struvite stones except for avoiding urinary alkalinization, which may worsen their development. Published by Elsevier Inc.

  15. Occupational stress and its predictors in radiographers

    Energy Technology Data Exchange (ETDEWEB)

    Rutter, D.R. [Centre for Research in Health Behaviour, Department of Psychology, University of Kent, Keynes College, Canterbury CT2 7NP (United Kingdom)], E-mail: d.r.rutter@kent.ac.uk; Lovegrove, M.J. [Department of Allied Health Professions, London South Bank University, London SE1 0AA (United Kingdom)

    2008-05-15

    Purpose: The purpose of this study was to establish the level of occupational stress in UK NHS radiographers, and to examine its causes. A total of more than 1600 radiographers sampled nationally completed a postal questionnaire. Four groups were represented - mammography, diagnostics, radiotherapy, and ultrasound - and both junior staff and superintendents were examined. Method: The questionnaire measured role ambiguity, role conflict, work problems, social support from colleagues, and perceived stress. Results: Levels of perceived stress were high in all four groups. The mean was significantly lower in the mammography group than the others, however, and junior staff reported lower levels than superintendents. Role ambiguity, role conflict and work problems all contributed significantly to stress, but the effects were sometimes buffered by social support from colleagues. Conclusion: The implications of the findings are discussed for theory and for policy and practice: occupational stress was predicted by intrinsic features of the job; the levels were similar to those reported by other NHS professionals; and the pattern of findings suggests possible ways to intervene to reduce it.

  16. Occupational stress and its predictors in radiographers

    International Nuclear Information System (INIS)

    Rutter, D.R.; Lovegrove, M.J.

    2008-01-01

    Purpose: The purpose of this study was to establish the level of occupational stress in UK NHS radiographers, and to examine its causes. A total of more than 1600 radiographers sampled nationally completed a postal questionnaire. Four groups were represented - mammography, diagnostics, radiotherapy, and ultrasound - and both junior staff and superintendents were examined. Method: The questionnaire measured role ambiguity, role conflict, work problems, social support from colleagues, and perceived stress. Results: Levels of perceived stress were high in all four groups. The mean was significantly lower in the mammography group than the others, however, and junior staff reported lower levels than superintendents. Role ambiguity, role conflict and work problems all contributed significantly to stress, but the effects were sometimes buffered by social support from colleagues. Conclusion: The implications of the findings are discussed for theory and for policy and practice: occupational stress was predicted by intrinsic features of the job; the levels were similar to those reported by other NHS professionals; and the pattern of findings suggests possible ways to intervene to reduce it

  17. Importance of radiographic monitoring of endoscopic sphincterotomy

    International Nuclear Information System (INIS)

    Greenberg, H.M.; Goldberg, H.I.; Shapiro, H.A.

    1981-01-01

    The radiographic features of endoscopic sphincterotomies performed in 44 patients were evaluated. Radiographic landmarks aided in proper sphincterotome placement and also disclosed conditions and anatomic variations that made catheter placement difficult. Fluoroscopic and radiographic monitoring not only assisted the performance of endoscopic sphincterotomy, but also confirmed successful results and revealed reasons for failure. Radiographic changes in the biliary tract after sphincterotomy, as well as potential complications of sphincterotomy, are discussed and illustrated

  18. Pulp polyp - A periapical lesion: Radiographic observational study

    Directory of Open Access Journals (Sweden)

    Kandagal V Suresh

    2015-01-01

    Full Text Available Introduction: Pulp polyp (PP is a chronic hyperplastic condition resulting in formation of granulation tissue and proliferative mass. The radiographic appearance of PP has innumerable presentations. Diagnosing and treatment planning of periapical lesions, heavily relies on the radiographic changes surrounding the root structures. Objective: To evaluate different radiographic periapical changes in clinically detected PP patients. Materials and Methods: Patients reporting to Department of Oral Medicine and Radiology and who were clinically diagnosed with PP by an oral diagnostician were subjected to radiographic examination. Digital intraoral periapical radiographs of 50 patients with PP were taken. Various periapical changes in the digital radiographs were recorded by a skilled oral radiologist. The data obtained was subjected to statistical analysis using SPSS ver 17.0 and P-value was set at <0.05 as significant. Result: Periapical changes like periodontal space widening (PDLW, loss of lamina dura, periapical abscess, periapical granuloma, hypercementosis, condensing osteitis and root resorption were noted. Periodontal space widening was seen in all patients (100%, loss of lamina dura was noted in 72%, periapical rarefying osteitis in 56%, condensing osteitis in 8%, hypercementosis, periapical granuloma, and root resorption were seen in 4% of PP patients. Majority of PP were asymptomatic (66%. Pulp polyp was commonly seen in mandibular first molar followed by mandibular second molar and maxillary first molar. Statistically significant difference was noticed between periapical changes in PP patients (P value <0.0001. All PP patients showed definite periapical changes suggesting it to be a periapical lesion. Conclusion: Pulp polyp is confined to the pulpal portion of the tooth which, may or may not cause changes in periapical region. The results of the present study showed that majority of the PP patients were associated with definite periapical

  19. Endodontic radiography: who is reading the digital radiograph?

    Science.gov (United States)

    Tewary, Shalini; Luzzo, Joseph; Hartwell, Gary

    2011-07-01

    Digital radiographic imaging systems have undergone tremendous improvements since their introduction. Advantages of digital radiographs over conventional films include lower radiation doses compared with conventional films, instantaneous images, archiving and sharing images easily, and manipulation of several radiographic properties that might help in diagnosis. A total of 6 observers including 2 endodontic residents, 3 endodontists, and 1 oral radiologist evaluated 150 molar digital periapical radiographs to determine which of the following conditions existed: normal periapical tissue, widened periodontal ligament, or presence of periapical radiolucency. The evaluators had full control over the radiograph's parameters of the Planmeca Dimaxis software program. All images were viewed on the same computer monitor with ideal vie-wing conditions. The same 6 observers evaluated the same 150 digital images 3 months later. The data were analyzed to determine how well the evaluators agreed with each other (interobserver agreement) for 2 rounds of observations and with themselves (intraobserver agreement). Fleiss kappa statistical analysis was used to measure the level of agreement among multiple raters. The overall Fleiss kappa value for interobserver agreement for the first round of interpretation was 0.34 (P value for interobserver agreement for the second round of interpretation was 0.35 (P fair (0.2-0.4) agreement among the 6 raters at both observation periods. A weighted kappa analysis was used to determine intraobserver agreement, which showed on average a moderate agreement. The results indicate that the interpretation of a dental radiograph is subjective, irrespective of whether conventional or digital radiographs are used. The factors that appeared to have the most impact were the years of experience of the examiner and familiarity of the operator with a given digital system. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All

  20. Retention of anatomy knowledge by student radiographers

    International Nuclear Information System (INIS)

    Hall, A. Susanne; Durward, Brian R.

    2009-01-01

    Introduction: Anatomy has long been regarded as an integral part of the core curriculum. However, anecdotal evidence suggests that long-term retention of anatomy knowledge may be deficient. This study aims to evidence whether student radiographers demonstrate the same level of knowledge of anatomy after a period of time has elapsed and to correlate to approaches to learning and studying. Methodology: A repeated measures design was utilised to measure retention of anatomy knowledge for both MCQs and short-response answers to a Practical Radiographic Anatomy Examination; alpha value p < 0.05. Fifty-one students from levels 2 and 3 were retested after a time lapse of 10 and 22 months respectively. The students were not aware that their knowledge was being retested. Approaches to learning and studying were measured using the ASSIST inventory. Results: Statistical analysis found no difference in performance on MCQ assessment, in either the combined sample or levels 2 and 3 separately, from baseline to retention occasions; average retention rate being 99%. However, a statistical difference in performance on PRAE assessment was found, with level 2 experiencing a larger reduction in scores; retention rate of 67% compared to level 3 at 77%. The students perceived themselves to be principally strategic in their approach to learning and studying but no strong relationships were found when correlated to test scores. Conclusion: The student radiographers in this study demonstrated varied anatomy retention rates dependent on assessment method employed and time interval that had elapsed. It is recommended that diverse teaching and assessment strategies are adopted to encourage a deeper approach to learning and studying.

  1. Comparative radiographic analysis on the anatomical axis in knee osteoarthritis cases: inter and intraobserver evaluation.

    Science.gov (United States)

    Matos, Luiz Felipe; Giordano, Marcos; Cardoso, Gustavo Novaes; Farias, Rafael Baptista; E Albuquerque, Rodrigo Pires

    2015-01-01

    To make a comparative inter and intraobserver analysis on measurements of the anatomical axis between panoramic radiographs of the lower limbs in anteroposterior (AP) view with bipedal weight-bearing, on short film. An accuracy study comparing radiographic measurements on 47 knees of patients attending the knee surgery outpatient clinic due to osteoarthritis. The radiographic evaluation used was as standardized for the total knee arthroplasty program, including panoramic AP views of the lower limbs and short radiographs of the knees in AP and lateral views, all with bipedal weight-bearing. Following this, the anatomical axis of the lower limbs or the femorotibial angle was measured by five independent examiners on the panoramic and short AP radiographs; three of the examiners were considered to be more experienced and two, less experienced. All the measurements were made again by the same examiners after an interval of not less than 15 days. The statistical analysis was performed using the intraclass correlation coefficient, in order to evaluate the inter and intraobserver concordance of the anatomical axis measurements. From the statistical analysis, it was observed that there was strongly significant concordance between the anatomical axis measurements on the panoramic and short radiographs, for all the five examiners and for both measurements. Under the conditions studied, short radiographs were equivalent to panoramic radiographs for evaluating the anatomical axis of the lower limbs in patients with advanced osteoarthritis. The measurements used also showed high rates of inter and intraobserver concordance and reproducibility.

  2. Comparative radiographic analysis on the anatomical axis in knee osteoarthritis cases: inter and intraobserver evaluation

    Directory of Open Access Journals (Sweden)

    Luiz Felipe Matos

    2015-06-01

    Full Text Available OBJECTIVE: To make a comparative inter and intraobserver analysis on measurements of the anatomical axis between panoramic radiographs of the lower limbs in anteroposterior (AP view with bipedal weight-bearing, on short film.METHODS: An accuracy study comparing radiographic measurements on 47 knees of patients attending the knee surgery outpatient clinic due to osteoarthritis. The radiographic evaluation used was as standardized for the total knee arthroplasty program, including panoramic AP views of the lower limbs and short radiographs of the knees in AP and lateral views, all with bipedal weight-bearing. Following this, the anatomical axis of the lower limbs or the femorotibial angle was measured by five independent examiners on the panoramic and short AP radiographs; three of the examiners were considered to be more experienced and two, less experienced. All the measurements were made again by the same examiners after an interval of not less than 15 days. The statistical analysis was performed using the intraclass correlation coefficient, in order to evaluate the inter and intraobserver concordance of the anatomical axis measurements.RESULTS: From the statistical analysis, it was observed that there was strongly significant concordance between the anatomical axis measurements on the panoramic and short radiographs, for all the five examiners and for both measurements.CONCLUSIONS: Under the conditions studied, short radiographs were equivalent to panoramic radiographs for evaluating the anatomical axis of the lower limbs in patients with advanced osteoarthritis. The measurements used also showed high rates of inter and intraobserver concordance and reproducibility.

  3. 21 CFR 892.1840 - Radiographic film.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film. 892.1840 Section 892.1840 Food... DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1840 Radiographic film. (a) Identification. Radiographic film is a device that consists of a thin sheet of radiotransparent material coated on one or both...

  4. Radiographic follow-up study of Little Leaguer's shoulder

    International Nuclear Information System (INIS)

    Kanematsu, Yoshiji; Iwase, Takenobu; Matsuura, Tetsuya; Suzue, Naoto; Sairyo, Koichi; Kashiwaguchi, Shinji; Iwame, Toshiyuki

    2015-01-01

    Little Leaguer's shoulder is a syndrome involving the proximal humeral epiphyseal plate. Conservative treatment usually resolves the symptoms. However, there are no reports of a radiographic follow-up study of this disease. The purpose of this study was to show the radiographic healing process of Little Leaguer's shoulder. A total of 19 male baseball players diagnosed as having Little Leaguer's shoulder were retrospectively evaluated. The mean age at first presentation was 12.7 years. External rotation anteroposterior radiographs of the shoulder were taken. All patients were treated with rest from throwing, and no throwing was recommended until remodeling was confirmed. Follow-up radiographs were taken at 1-month intervals to assess healing. All patients were observed until healing was confirmed radiographically, after which they returned to baseball. The mean follow-up period was 8.5 months. In addition to radiography, patients were asked whether they had any symptoms and whether they had been able to return to baseball. At the first examination, radiographs showed a wider epiphyseal plate of the throwing side compared with the asymptomatic contralateral shoulder. Healing was observed in all cases. Healing occurred first along the medial side and was then extended laterally. The mean time required for healing was 4.7 months. All patients were able to return to playing baseball at their pre-injury level of play and were asymptomatic when examined at the final follow-up. The healing process of Little Leaguer's shoulder advanced from medial to lateral, and healing was achieved about 5 months after initial examination. (orig.)

  5. Shock Wave Lithotripsy in Ureteral Stones: Evaluation of Patient and Stone Related Predictive Factors

    Directory of Open Access Journals (Sweden)

    Ozgur Yazici

    2015-08-01

    Full Text Available ABSTRACTPurpose:To evaluate the patient and stone related factors which may influence the final outcome of SWL in the management of ureteral stones.Materials and Methods:Between October 2011 and October 2013, a total of 204 adult patients undergoing SWL for single ureteral stone sizing 5 to 15 mm were included into the study program. The impact of both patient (age, sex, BMI, and stone related factors (laterality, location, longest diameter and density as CT HU along with BUN and lastly SSD (skin to stone distance on fragmentation were analysed by univariate and multivariate analyses. Results: Stone free rates for proximal and distal ureteral stones were 68.8% and 72.7%, respectively with no statistically significant difference between two groups (p=0.7. According to univariate and multivariate analyses, while higher BMI (mean: 26.8 and 28.1, p=0.048 and stone density values (mean: 702 HU and 930 HU, p<0.0001 were detected as statistically significant independent predictors of treatment failure for proximal ureteral stones, the only statistically significant predicting parameter for the success rates of SWL in distal ureteral stones was the higher SSD value (median: 114 and 90, p=0.012.Conclusions:Our findings have clearly shown that while higher BMI and increased stone attenuation values detected by NCCT were significant factors influencing the final outcome of SWL treatment in proximal ureteral stones; opposite to the literature, high SSD was the only independent predictor of success for the SWL treatment of distal ureteral stones.

  6. Mourning in Bits and Stone

    DEFF Research Database (Denmark)

    Sabra, Jakob Borrits

    We mourn our dead, publicly and privately, online and offline. Cemeteries, web memorials and social network sites make up parts of todays intricately weaved and interrelated network of death, grief and memorialization practices [1]–[5]. Whether cut in stone or made of bits, graves, cemeteries......, memorials, monuments, websites and social networking services (SNS) all are alterable, controllable and adaptive. They represent a certain rationale contrary to the emotive state of mourning (e.g. gravesites function as both spaces of internment and places of spiritual and emotional recollection). Following...... and memorialization by discussing the publicly and privately digital and social death from a spatial, temporal, physical and digital angle. Further the paper will reflect on how to encompass shifting trends and technologies in ‘traditional’ spaces of mourning and remembrance....

  7. In bits, bytes and stone

    DEFF Research Database (Denmark)

    Sabra, Jakob Borrits; Andersen, Hans Jørgen

    The digital spheres of Information and Communication Technologies (ICT) and Social Network Services (SNS) are influencing 21st. century death. Today the dying and the bereaved attend mourning and remembrance both online and offline. Combined, the cemeteries, web memorials and social network sites...... designs'. Urns, coffins, graves, cemeteries, memorials, monuments, websites, applications and software services, whether cut in stone or made of bits, are all influenced by discourses of publics, economics, power, technology and culture. Designers, programmers, stakeholders and potential end-users often...... the respondents and interviewees are engaged with a prototype design that encompasses digitally enhanced experiences and interactions regarding mourning, memory and remembrance. The design is situated in a traditional public place of death, the Almen Cemetery of Aalborg in Denmark....

  8. Radiographic display of carious lesions and cavitation in approximal surfaces

    DEFF Research Database (Denmark)

    Wenzel, Ann

    2014-01-01

    cavitation in approximal surfaces. Nonetheless, there are several drawbacks with CBCT, such as radiation dose, costs and imaging artefacts. Therefore, CBCT cannot be advocated at current as a primary radiographic examination with the aim of diagnosing cavitated carious lesions. Conclusions. Bitewing...

  9. The radiographer's professional role in practical aspects of radiation protection

    International Nuclear Information System (INIS)

    Shrimpton, J.A.

    1995-01-01

    The subjects discussed were qualified radiographer definition, unnecessary x-rays exposure in x-rays examination and it's contribution in radiation protection practices, the improvement in procedures, and reviews of booklet called 'making the best use of a Dept of Clinical Radiology, UK

  10. A Reduction in Radiographic Exposure and Image Quality in Film ...

    African Journals Online (AJOL)

    Purpose: To develop a protocol for the optimization of diagnostic chest radiography examination, the effect of radiographic exposure reduction on image quality is investigated. Procedure: Fourty-eight adult patients presenting for posterior-anterior (PA) chest radiography in a tertiary health care centre were categorized into 3 ...

  11. Radiographical investigation of fluid penetration processes in natural stones used in historical buildings

    Czech Academy of Sciences Publication Activity Database

    Koudelka_ml., Petr; Jandejsek, Ivan; Doktor, Tomáš; Kytýř, Daniel; Jiroušek, Ondřej; Zíma, Pavel; Drdácký, Miloš

    2014-01-01

    Roč. 9, č. 5 (2014), C05040 ISSN 1748-0221. [International workshop on radiation imaging detectors /15./. Paris, 23.06.2013-27.06.2013] R&D Projects: GA ČR(CZ) GBP105/12/G059 Institutional support: RVO:68378297 Keywords : computerized tomography (CT) * computed radiography (CR) * inspection with X-rays * X-ray radiography * digital radiography (DR) Subject RIV: JN - Civil Engineering Impact factor: 1.399, year: 2014 http://iopscience.iop.org/1748-0221/9/05/C05040

  12. Radiographic control of mineral fibre-reinforced cement plates

    International Nuclear Information System (INIS)

    Domanus, J.C.; Moeller Jensen, L.

    1980-03-01

    The usefulnes of the radiographic technique in the examination of Spinrock fibres reinforced cement plates was investigated with soft X-rays. A preliminary investigation has shown that soft X-rays are most suitable for radiography of cement plates, and therefore a 50 kV X-ray machine with a 0.5 mm focus and beryllium window X-ray tube was used througout the investigation. X-ray films of different speed and graininess were used, and it was proved that a relatively fast Kodak Industrex D film can produce radiographs of adequate quality. An Agfa-Gevaert Structurix IC paper can also be used. (author)

  13. Patients exposure assessment for radiographic procedures in diagnostic radiology

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Stankovic, K.; Lazarevic, Dj.; Ciraj-Bjelac, O.)

    2007-01-01

    In this work the results of dose assessment for the most frequent radiographic procedures in diagnostic radiology are shown. Entrance surface doses were assessed for 7 radiographic procedures. Three hospitals, six x-ray units in total, were enrolled in investigation. Patient doses were estimated based on results of x-ray tube output measurements. Finally, doses were compared with Diagnostic reference level. Higher dose values were observed for chest examinations. In comparison with results from other countries, doses from this procedure in Serbia are significantly higher. Estimated doses for other procedures were well below Diagnostic reference levels [sr

  14. Comparison of secondary signs as shown by unenhanced helical computed tomography in patients with uric acid or calcium ureteral stones

    Directory of Open Access Journals (Sweden)

    Yii-Her Chou

    2012-06-01

    Full Text Available Unenhanced helical computed tomography (UHCT has evolved into a well-accepted diagnostic method in patients with suspected ureterolithiasis. UHCT not only shows stones within the lumen of the ureter, it also permits evaluation of the secondary signs associated with ureteral obstruction from stones. However, there we could find no data on how secondary signs might differ in relation to different compositions of ureteral stones. In this study, we compared the degree of secondary signs revealed by UHCT in uric acid stone formers and in patients forming calcium stones. We enrolled 117 patients with ureteral stones who underwent UHCT examination and Fourier transform infra-red analysis of stone samples. Clinical data were collected as follows: age, sex, estimated glomerular filtration rate (eGFR, urine pH, and radiological data on secondary signs apparent on UHCT. The uric acid stone formers had significantly lower urine pH and eGFR in comparison to calcium stone formers, and on UHCT they also had a higher percentage of the secondary signs, including rim sign (78.9% vs. 60.2%, hydroureter (94.7% vs. 89.8%, perirenal stranding (84.2% vs. 59.2% and kidney density difference (73.7% vs. 50.0%. The radiological difference was statistically significant for perirenal stranding (p=0.041. In conclusion, we found that UHCT scanning reveals secondary signs to be more frequent in patients with uric acid ureteral stones than in patients with calcium stones, a tendency that might result from an acidic urine environment.

  15. Predictive value of radiographic findings in gastritis

    International Nuclear Information System (INIS)

    Remley, K.B.; Mann, F.A.; Simons, M.A.

    1986-01-01

    In a retrospective review of biphasic upper gastrointestinal (GI) tract examinations in 300 consecutive patients with abdominal pain, blood loss, nausea and vomiting, weight loss or dysphagia, the author evaluated the frequency of radiographic findings suggestive of gastritis. Forty-eight patients had undergone endoscopy within 1 week of upper GI tract examination. ''Best findings'' were defined by receiver operating characteristic wave analysis of individual findings, including aphthous lesions, serrated or nodular folds, marginal spiculation, and luminal constriction. Most false negative studies were in the fundus or proximal body; most false positive studies were in the antrum. They present a pictorial dictionary of findings and data for use of ''best findings'' to improve sensitivity and specificity in the diagnosis of gastritis

  16. Neutron radiographic findings in light water reactor fuel

    International Nuclear Information System (INIS)

    Domanus, J.C.

    1979-06-01

    The assessment of neutron radiographs of nuclear fuel elements can be much easier, faster and simpler if reference can be made to typical defects, which can be revealed by neutron radiography. In other fields of industrial radiography collections of reference radiographs, showing typical defects in welding, or casting have been completed and published long ago. Since 1974 neutron radiography is routinely used at Risoe National Laboratory, Denmark, for the quality and performance control of nuclear fuel. About 2000 neutron radiographs were taken, mainly during the post irradiation examination of light water reactor fuel. During assessment of neutron radiographs some typical defects of the fuel were found and it was felt that a classification of such defects will help to speed up the assessment procedure. Therefore an attempt was made to establish such a classification, which is currently used at Risoe now. This classification is presented in this atlas, which contains 36 neutron radiographs reproduced on film (in original size) and on paper (twice enlarged). (author)

  17. Radiographic features of paediatric pneumocystis pneumonia - a historical perspective

    International Nuclear Information System (INIS)

    Pitcher, R.D.; Zar, H.J.

    2008-01-01

    Aim: To determine differences between the plain radiographic features of paediatric pneumocystis pneumonia (PCP) recorded before the emergence of human immunodeficiency virus (HIV) in 1982 and those documented in the HIV era. To establish differences in the radiographic features of PCP documented in HIV-infected children in developed and developing countries. Method: A Medline search of articles was conducted from 1950 to 2006, using the terms 'pneumocystis pneumonia in children' and 'chest radiographic features' or 'bilateral opacification' or 'lobar consolidation' or 'asymmetrical opacification' or 'pneumatocoeles' or 'cavities' or 'pneumothorax' or 'pneumomediastinum' or 'pleural effusion' or 'mediastinal adenopathy' or 'nodules' or 'normal chest radiography'. Appropriate articles were retrieved, radiological data extracted, reference lists examined and hand searches of referenced articles conducted. Results: Diffuse bilateral 'ground-glass' or alveolar pulmonary opacification, which may show some asymmetry, has been consistently documented as the commonest radiographic finding in childhood PCP throughout the period under review. The less common radiological features of PCP in children are similar to those in adults. In developed countries, PCP-related pulmonary air cysts have been reported at an earlier age in HIV-infected children, compared with uninfected children. PCP-related air cysts, pneumothorax, and pneumomediastinum have been reported in children in developed but not in developing countries. Conclusion: The radiological features of paediatric PCP documented before the HIV epidemic are similar to those recorded in the HIV era. Further study of the determinants of the uncommon radiographic features in children is warranted

  18. Radiographic evaluation of maxillofacial fractures

    International Nuclear Information System (INIS)

    Litwan, M.; Fliegel, C.

    1986-01-01

    The course and configuration of typical maxillofacial fractures (type Le Fort I-III) and lateral maxillary fractures including the zygomatic arch were reconstructed in detail by application of barium paste on a bony skull and radiogrpahs in standard projections were performed and evaluated. It was obvious from the resulting radiographs that for most maxillofacial fractures a half axial or Water's view was most helpful. Lateral views only give additional information when there is a considerable degree of dislocation of fragments. Comparison with a prediatric skull of 8 years of age demonstrated that fractures of the zygomatic arch in this age group cannot be demonstrated by the typical submento-vertical view, but are shown on a Towne projection. The radiographic appearance of important maxillofacial fractures is demonstrated. The necessity of further studies in cases where reconstructive surgery appears necessary is discussed and CT rather then conventional tomography is advocated. (orig.) [de

  19. Quantitative radiographic analysis of fiber reinforced polymer composites.

    Science.gov (United States)

    Baidya, K P; Ramakrishna, S; Rahman, M; Ritchie, A

    2001-01-01

    X-ray radiographic examination of the bone fracture healing process is a widely used method in the treatment and management of patients. Medical devices made of metallic alloys reportedly produce considerable artifacts that make the interpretation of radiographs difficult. Fiber reinforced polymer composite materials have been proposed to replace metallic alloys in certain medical devices because of their radiolucency, light weight, and tailorable mechanical properties. The primary objective of this paper is to provide a comparable radiographic analysis of different fiber reinforced polymer composites that are considered suitable for biomedical applications. Composite materials investigated consist of glass, aramid (Kevlar-29), and carbon reinforcement fibers, and epoxy and polyether-ether-ketone (PEEK) matrices. The total mass attenuation coefficient of each material was measured using clinical X-rays (50 kev). The carbon fiber reinforced composites were found to be more radiolucent than the glass and kevlar fiber reinforced composites.

  20. Imaging of juvenile spondyloarthritis. Part I: Classifications and radiographs

    Directory of Open Access Journals (Sweden)

    Iwona Sudoł-Szopińska

    2017-09-01

    Full Text Available Juvenile spondyloarthropathies are manifested mainly by symptoms of peripheral arthritis and enthesitis. By contrast with adults, children rarely present with sacroiliitis and spondylitis. Imaging and laboratory tests allow early diagnosis and treatment. Conventional radiographs visualize late inflammatory lesions and post-inflammatory complications. Early diagnosis is possible with the use of ultrasonography and magnetic resonance imaging. The first part of the article presents classifications of juvenile spondyloarthropathies and discusses their radiographic presentation. Typical radiographic features of individual types of juvenile spondyloarthritis are listed (including ankylosing spondylitis, juvenile psoriatic arthritis, reactive arthritis and arthritis in the course of inflammatory bowel diseases. The second part will describe changes visible on ultrasonography and magnetic resonance imaging. In patients with juvenile spondyloarthropathies, these examinations are conducted to diagnose inflammatory lesions in peripheral joints, tendon sheaths, tendons and bursae. Moreover, magnetic resonance imaging also visualizes early inflammatory changes in the axial skeleton and subchondral bone marrow edema, which is considered an early sign of inflammation.

  1. Early diagnosis of atherosclerosis with panoramic radiographs: a review

    Directory of Open Access Journals (Sweden)

    Daiane Landim Borba

    Full Text Available Abstract Carotid artery disease has been linked with cerebral vascular accident, also known as stroke, cerebral hemorrhage, or cerebral ischemia. It is caused by narrowing or obstruction of arteries in the neck (the carotid arteries that are responsible for transporting blood from the aorta to the brain. Panoramic radiographs are used in dentistry to show both dental arches as a supplement to the clinical dental examination. The objective of this study is to highlight the importance of panoramic radiographs for diagnosis of arterial disease, by means of a bibliographic review. The PubMed database was searched using the keywords “atherosclerosis” and “panoramic”, with the filters “last 5 years” and “humans”. Twenty articles were identified, six of which were chosen for this study because they were open access. The review concluded that panoramic radiographs enable early diagnosis of carotid artery calcification, resulting in earlier interventions, and offer an accessible cost.

  2. Pulmonary edema: radiographic differential diagnosis

    International Nuclear Information System (INIS)

    Yoo, Dong Soo; Choi, Young Hi; Kim, Seung Cheol; An, Ji Hyun; Lee, Jee Young; Park, Hee Hong

    1997-01-01

    To evaluate the feasibility of using chest radiography to differentiate between three different etiologies of pulmonary edema. Plain chest radiographs of 77 patients, who were clinically confirmed as having pulmonary edema, were retrospectively reviewed. The patients were classified into three groups : group 1 (cardiogenic edema : n = 35), group 2 (renal pulmonary edema : n = 16) and group 3 (permeability edema : n = 26). We analyzed the radiologic findings of air bronchogram, heart size, peribronchial cuffing, septal line, pleural effusion, vascular pedicle width, pulmonary blood flow distribution and distribution of pulmonary edema. In a search for radiologic findings which would help in the differentiation of these three etiologies, each finding was assessed. Cardiogenic and renal pulmonary edema showed overlapping radiologic findings, except for pulmonary blood flow distribution. In cardiogenic pulmonary edema (n=35), cardiomegaly (n=29), peribronchial cuffing (n=29), inverted pulmonary blood flow distribution (n=21) and basal distribution of edema (n=20) were common. In renal pulmonary edema (n=16), cardiomegaly (n=15), balanced blood flow distribution (n=12), and central (n=9) or basal distribution of edema (n=7) were common. Permeability edema (n=26) showed different findings. Air bronchogram (n=25), normal blood flow distribution (n=14) and peripheral distribution of edema (n=21) were frequent findings, while cardiomegaly (n=7), peribronchial cuffing (n=7) and septal line (n=5) were observed in only a few cases. On plain chest radiograph, permeability edema can be differentiated from cardiogenic or renal pulmonary edema. The radiographic findings which most reliably differentiated these two etiologies were air bronchogram, distribution of pulmonary edema, peribronchial cuffing and heart size. Only blood flow distribution was useful for radiographic differentiation of cardiogenic and renal edema

  3. Occupational health and the radiographer

    International Nuclear Information System (INIS)

    Stronach, T.

    1990-01-01

    This paper identifies some of the occupational health hazards faced by radiographers in the hospital environment. There has been very little work done in this area in the past, and as the subject is so large this paper can do little other than raise some of the issues . The hazards addressed include: radiation, ergonomics, chemical, environmental, biological, occupational injury and accident, stress. 14 refs., 2 figs

  4. Pattern of family history in stone patients.

    Science.gov (United States)

    Marickar, Y M Fazil; Salim, Abiya; Vijay, Adarsh

    2009-12-01

    Genetic predisposition to urolithiasis is a much discussed topic. The objective of this paper is to identify the types of family members of proved urinary stone patients, who have a history of urinary stone formation. The study population consisted of 2,157 urinary stone patients interviewed in 2003-2007 in the urinary stone clinic. Family members with stone history were classified as group 1--first order single (one person in the immediate family-father, mother, siblings, or children), group 2--first order multiple (more than one member in the above group), group 3--second order single (one person in the blood relatives in family--grandparents, grandchildren, uncles, aunts, cousins, etc.) and group 4--second order multiple (more than one member in the above group). Of the 2,157 patients studied, 349 patients gave positive history of stone disease constituting 16.18%. Of these, 321 were males and 28 were females. Subdivision of the family members showed that 282 patients (80.80%) had single family member with stones and the rest 67 (19.20%) had multiple family members with history of stone disease. Group 1 which constituted one family member in the immediate family had 255 involvements (father: 88, mother: 16, brother: 135, sister: 2, son: 10, and daughter: 4); Group 2 with multiple members in the immediate family constituted 51 relatives; of these, father and brother combination was the most common with 35 occurrences. Group 3 with one person in the distant relatives in family namely grandparents, grand children, uncles, aunts, cousins, etc. constituted 27 occurrences and Group 4 with more than one member in the distant family constituted 16 occurrences. It is concluded that single family member involvement was more than multiple involvements. Males predominated. Stone occurrence was more in the immediate family members than distant relatives. Brothers formed the most common group to be involved with stone disease. Study of stone risk in the family members should

  5. MRI and radiographic findings in Currarino's triad

    International Nuclear Information System (INIS)

    Pfluger, T.; Czekalla, R.; Koletzko, S.; Muensterer, O.; Willemsen, U.F.; Hahn, K.

    1996-01-01

    Currarino's triad is a rare complex of a congential sacral bony abnormality, anorectal malformation and a presacral mass. Intractable constipation since birth is the leading symptom of this triad, which follows an autosomal dominant mode of heredity. We report conventional radiographic and MR findings in one family consisting of a mother and her two daughters. In all three cases, radiography revealed an abnormality of the os sacrum, the so-called scimitar sacrum. MR examination, undertaken next in our institution, was applied with T1-, T2- and proton density weighted sequences in all three orientations before and after i.v. application of gadolinium diethylene-triamine-pentaacetic acid (Gd-DTPA). In two patients we were able to diagnose the complete form of the triad and in one patient an incomplete form. In any case of a radiographically diagnosed scimitar sacrum in combination with constipation. Currarino's triad should be considered. MRI, as the method of choice, should be the next step to detect a presacral mass and any anomalies of the spinal canal. The importance of early recognition lies in the high morbidity and mortality rates resulting from this disorder. (orig.)

  6. Observer POD for radiographic testing

    Energy Technology Data Exchange (ETDEWEB)

    Kanzler, Daniel; Mueller, Christina; Bertovic, Marija [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany); Pitkaenen, Jorma [Posiva Oy, Eurajoki (Finland)

    2013-07-01

    The radiographic testing is an important non-destructive testing method, especially in industrial areas where people could be injured in case of failing of a component. There it is a mighty method to find volumetric defects. As bigger the penetrated length of the defect in the component is, as bigger is the radiographic contrast. The detectability of volumetric defects in its turn is not only depending on the contrast but also on the noise, the defect area and its shape. The currently applied POD approach uses mostly only the contrast and the noise as detection threshold. This does not reflect accurately the results of evaluations by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the area of the defect. The presentation shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data. This approach was developed within a joint project with the company POSIVA, which is constructing a final depository for high active nuclear fuels in Finland. Radiographic testing is one of the NDT-methods they use to test the electron beam welds of the copper canisters. The copper canisters will be used in the depository as a corrosion barrier within the waste management concept. (Published as a poster session.)

  7. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1986-01-01

    Automation, the removal of the human element in inspection, has not been generally applied to film radiographic NDT. The justication for automating is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 8 x 10 9 bits per 14 x 17. The equivalent to 2200 computer floppy discs. Parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, computer aided interpretation appears on the horizon. A unit which laser scans a 14 x 17 (inch) film in 6 - 8 seconds can digitize film information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for Film Digital Radiography System) is moving toward 50 micron (*approx* 16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. We expect the automated system to appear first in parts (modules) as certain operations are automated. The future will see it all come together in an automated film radiographic NDT system (author) [pt

  8. Cervical spine motion: radiographic study

    International Nuclear Information System (INIS)

    Morgan, J.P.; Miyabayashi, T.; Choy, S.

    1986-01-01

    Knowledge of the acceptable range of motion of the cervical spine of the dog is used in the radiographic diagnosis of both developmental and degenerative diseases. A series of radiographs of mature Beagle dogs was used to identify motion within sagittal and transverse planes. Positioning of the dog's head and neck was standardized, using a restraining board, and mimicked those thought to be of value in diagnostic radiology. The range of motion was greatest between C2 and C5. Reports of severe disk degeneration in the cervical spine of the Beagle describe the most severely involved disks to be C4 through C7. Thus, a high range of motion between vertebral segments does not seem to be the cause for the severe degenerative disk disease. Dorsoventral slippage between vertebral segments was seen, but was not accurately measured. Wedging of disks was clearly identified. At the atlantoaxio-occipital region, there was a high degree of motion within the sagittal plane at the atlantoaxial and atlanto-occipital joints; the measurement can be a guideline in the radiographic diagnosis of instability due to developmental anomalies in this region. Lateral motion within the transverse plane was detected at the 2 joints; however, motion was minimal, and the measurements seemed to be less accurate because of rotation of the cervical spine. Height of the vertebral canal was consistently noted to be greater at the caudal orifice, giving some warning to the possibility of overdiagnosis in suspected instances of cervical spondylopathy

  9. Efficacy and safety of totally tubeless standard percutaneous nephrolithotomy in patients with kidney stones

    Directory of Open Access Journals (Sweden)

    Cemil Aydın

    2014-09-01

    Full Text Available Objective: Percutaneous nephrolithotomy (PNL is the first- line treatment for large and complex renal calculi. In this study, we aimed to compare the efficacy and safety of the totally tubeless PNL versus the standard PNL. Methods:Between January 2012 and July 2013, 73 selected patients were treated standard or totally tubeless PNL, nephrostomy tube and ureteral stent was not placed at the end of the operation in 35 (39.7% (Group 1 of them and 38 (43.1% (Group 2 patient underwent standard PNL. Stone disintegration was performed with a pneumatic lithotripter. We retrospectively compared patient and stone characteristics, operation time, duration of hospitalization, analgesia requirements, stone-free rate, operative findings, blood loss, and perioperative complications between two groups. Results:The mean operation time, excluding the preparation course, was 38,3±15,4 minutes vs 51,2±12,9 minutes and mean fluoroscopy time was 4,5±2,4 minutes vs 4,8±2,1 minutes, respectively. No significant intraoperative complication or indication additional access or second-look PNL due to residual stones was observed. In both groups none of the patients demonstrated a urinoma, hemorrhage or residual stones in postoperative ultrasonography and plain radiograph. Blood transfusion was needed only in a patient vs two patients for group 1 and 2, respectively. There were no significant differences in preoperative patient characteristics, postoperative complications between two groups, but the totally tubeless PNL group showed a shorter hospitalization and a lesser analgesic requirement compared with other group. Conclusion: Absence of the nephrostomy tube and ureteral stent may help in keeping the patient comfortable after the operation and reduction in the analgesia requirement and length of hospital stay. We believe totally tubeless PNL is safe and effective management option in properly selected cases.

  10. Clinical use of patient decision-making aids for stone patients.

    Science.gov (United States)

    Lim, Amy H; Streeper, Necole M; Best, Sara L; Penniston, Kristina L; Nakada, Stephen Y

    2017-08-01

    Patient decision-making aids (PDMAs) help patients make informed healthcare decisions and improve patient satisfaction. The utility of PDMAs for patients considering treatments for urolithiasis has not yet been published. We report our experience using PDMAs developed at our institution in the outpatient clinical setting in patients considering a variety of treatment options for stones. Patients with radiographically confirmed urolithiasis were given PDMAs regarding treatment options for their stone(s) based on their clinical profile. We assessed patients' satisfaction, involvedness, and feeling of making a more informed decision with utilization of the PDMAs using a Likert Scale Questionnaire. Information was also collected regarding previous stone passage, history and type of surgical intervention for urolithiasis, and level of education. Patients (n = 43; 18 males, 23 females and two unknown) 53 +/- 14years old were included. Patients reported that they understood the advantages and disadvantages outlined in the PDMAs (97%), that the PDMAs helped them make a more informed decision (83%) and felt more involved in the decision making process (88%). Patients reported that the aids were presented in a balanced manner and used up-to-date scientific information (100%, 84% respectively). Finally, a majority of the patients prefer an expert's opinion when making a treatment decision (98%) with 73% of patients preferring to form their own opinion based on available information. Previous stone surgery was associated with patients feeling more involved with the decision making process (p = 0.0465). PDMAs have a promising role in shared decision-making in the setting of treatment options for nephrolithiasis.

  11. Diagnostic radiology of pet and wild birds: a review I. Radiographic techniques and radiographs of healthy birds

    International Nuclear Information System (INIS)

    Beregi, A.; Molnar, V.; Felkai, F.; Biro, F.; Szentgali, Zs.

    1999-01-01

    The first part of the present review summaries the basic technical conditions of radiological examinations, analyses the radiographic features of healthy birds, and describes the procedure and radiological indications of contrast radiography. (This paper can be seen on the Internet at: http://www.akkrt.hu)

  12. Stability of Reshaping Breakwaters with Special Reference to Stone Durability

    DEFF Research Database (Denmark)

    Frigaard, Peter; Hald, Tue; Burcharth, H. F.

    1996-01-01

    inherently cause some breakage and abrasion of the individual stones and thereby also reduced stability. In order to avoid excessive abrasion a high stone quality is demanded or larger stones must be applied when constructed. To allow the designer to account for abrasion and armour stone breakage due...

  13. Factors affecting lower calyceal stone clearance after Extracorporeal ...

    African Journals Online (AJOL)

    shanker

    have been identified [1,3]. These include stone characteristics, the type of lithotripter used, LPC anatomy and body habitus. For iso- lated LPC stones, the pelvicalyceal angle, infundibulum length and width are considered important determinants for stone clearance. The impact of body habitus on stone clearance has so far ...

  14. Retrograde intrarenal stone surgery for extracorporeal shock-wave lithotripsy-resistant kidney stones

    DEFF Research Database (Denmark)

    Jung, Helene; Nørby, Bettina; Osther, Palle Jörn

    2006-01-01

    OBJECTIVE: The newer flexible ureteroscopes, 150-200-microm holmium YAG laser fibres and superflexible Dormia baskets have made it possible to reach and treat stones in all parts of the kidney. The object of this evaluation was to study the outcome of retrograde intrarenal stone surgery (RIRS......) for extracorporeal shock-wave lithotripsy (ESWL)-resistant kidney stones. MATERIAL AND METHODS: A total of 38 consecutive patients (18 males, 20 females) participated in the study. All patients had undergone ESWL prior to RIRS without success. In all cases the stones could be reached with the endoscope. Calculi...... ranged in size from 3 to 20 mm (mean 9 mm). In 32 cases the stones were fragmented using a holmium YAG laser and in six the stones could be extracted using zero-tip Dormia baskets without fragmentation. Sixteen patients had lower calyceal calculi and eight had an abnormal anatomy of the upper urinary...

  15. Quantitative analysis of bowel gas by plain abdominal radiograph combined with computer image processing

    International Nuclear Information System (INIS)

    Gao Yan; Peng Kewen; Zhang Houde; Shen Bixian; Xiao Hanxin; Cai Juan

    2003-01-01

    Objective: To establish a method for quantitative analysis of bowel gas by plain abdominal radiograph and computer graphics. Methods: Plain abdominal radiographs in supine position from 25 patients with irritable bowel syndrome (IBS) and 20 health controls were studied. A gastroenterologist and a radiologist independently conducted the following procedure on each radiograph. After the outline of bowel gas was traced by axe pen, the radiograph was digitized by a digital camera and transmitted to the computer with Histogram software. The total gas area was determined as the pixel value on images. The ratio of the bowel gas quantity to the pixel value in the region surrounded by a horizontal line tangential to the superior pubic symphysis margin, a horizontal line tangential to the tenth dorsal vertebra inferior margin, and the lateral line tangential to the right and left anteriosuperior iliac crest, was defined as the gas volume score (GVS). To examine the sequential reproducibility, a second plain abdominal radiograph was performed in 5 normal controls 1 week later, and the GVS were compared. Results: Bowel gas was easily identified on the plain abdominal radiograph. Both large and small intestine located in the selected region. Both observers could finish one radiographic measurement in less than 10 mins. The correlation coefficient between the two observers was 0.986. There was no statistical difference on GVS between the two sequential radiographs in 5 health controls. Conclusion: Quantification of bowel gas based on plain abdominal radiograph and computer is simple, rapid, and reliable

  16. Introduction. Leave no stone unturned: Perspectives on ground stone artefact research

    OpenAIRE

    Danny Rosenberg; Yorke Rowan; Tatjana Gluhak

    2016-01-01

    Ground stone tools served in many physical and social contexts through millennia, reflecting a wide variety of functions. Although ground stone tool studies were neglected for much of early archaeology, the last few decades witnessed a notable international uptick in the way archaeologists confront this multifaceted topic. Today, with the advance of archaeology as a discipline, research into ground stone artefacts is moving into a new phase that integrates high resolution documentation with n...

  17. Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jia; Qu, Mingliang; Duan, Xinhui; Takahashi, Naoki; Kawashima, Akira; Leng, Shuai; McCollough, Cynthia H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2012-12-15

    To develop a dual-energy CT (DECT) method for differentiating uric acid (UA) from non-UA stones in the presence of iodinated contrast medium. Thirty UA and 45 non-UA stones were selected after infra-red spectroscopic analysis and independently placed in a 1.5-ml vial, which was filled first with saline and then with increasing concentrations of iodine. For each condition, tubes were put in a 35-cm water phantom and examined using a dual-source CT system at 100 and 140 kV. Virtual unenhanced images created from CT data sets of the stones in iodine-containing solutions provided position and volume information. This map was used to calculate a CT number ratio to differentiate stone type. A region-growing method was developed to improve the ability to differentiate between UA and non-UA stones with iodinated contrast medium. The sensitivity for detecting UA stones was 100 % for unenhanced images but fell to 18 % with 20 mgI/ml iodine solution and 0 % for higher concentrations. With region growing, the sensitivity for detecting UA stones was increased to 100 %, 82 %, 57 %, 50 % and 21 % for iodine solutions of 20, 40, 60, 80 and 100 mgI/ml. The region-growing method improves differentiation of UA from non-UA stones on contrast-enhanced DECT urograms. (orig.)

  18. The Incidence of Complications in Single-stage Endoscopic Stone Removal for Patients with Common Bile Duct Stones: A Propensity Score Analysis.

    Science.gov (United States)

    Saito, Hirokazu; Kadono, Yoshihiro; Kamikawa, Kentaro; Urata, Atsushi; Imamura, Haruo; Matsushita, Ikuo; Kakuma, Tatsuyuki; Tada, Shuji

    2018-02-15

    Objective Single-stage endoscopic stone removal for choledocholithiasis is an advantageous approach because it is associated with a shorter hospital stay; however, few studies have reported the incidence of complications related to this procedure in detail. The aim of this study was to examine the incidence of complications and efficacy of this procedure. Methods This retrospective study investigated the incidence of complications in 345 patients with naive papilla who underwent therapeutic endoscopic retrograde cholangiopancreatography (ERCP) for choledocholithiasis at three institutions between April 2014 and March 2016 by a propensity score analysis. The efficacy of single-stage endoscopic stone removal was assessed based on a hospital stay of within 7 days and the number of ERCP attempts. Results Among 114 patients who underwent single-stage endoscopic stone removal, 15 patients (13.2%) experienced complications. Among the remaining 231 patients in the two-stage endoscopic stone removal group, complications were observed in 17 patients (7.4%). The propensity score analysis, which was adjusted for confounding factors, revealed that single-stage endoscopic stone removal was not a significant risk factor for complications (p=0.52). In patients in whom >10 min was required for deep cannulation, single-stage endoscopic stone removal was not a significant risk factor for complications in the propensity score analysis (p=0.37). In the single-stage group, the proportion of patients with a hospital stay of within 7 days was significantly higher and the number of ERCP attempts was significantly lower in comparison to the two-stage group (p <0.0001 and <0.0001, respectively). Conclusion Single-stage endoscopic stone removal did not increase the incidence of complications associated with ERCP and was effective for reducing the hospital stay and the number of ERCP attempts.

  19. Compositions of stone and stone surface materials of historical monuments from Vidzeme and Zemgale

    International Nuclear Information System (INIS)

    Actins, A.; Spricis, A.; Zekunde, A.; Nemerova, A.

    2004-01-01

    By means of x-ray analysis composition of stone and stone surface materials of historical monuments from Vidzeme and Zemgale was investigated. Corrosion products of tuffa materials were identified on surfaces of some investigated monuments. Similarity of composition of products of stone corrosion for monuments from Latvia and Poland was recognised. Content of heavy metals at stone materials of historical monuments and at the surface layers of these monuments was investigated by means of atomic absorption and potentiometric stripping methods. Reasons of formation of compounds and pollution of investigated samples were discussed. (full text)

  20. IGCP 637 Heritage Stone Designation: A UNESCO and IUGS project on natural stones

    Science.gov (United States)

    Pereira, Dolores; Cooper, Barry; Schouenborg, Björn; Marker, Brian; Kramar, Sabina

    2017-04-01

    IGCP 637 was approved in 2015 to facilitate establishment of a new international geological standard for building and ornamental stones. Formal international recognition of those natural stone types that have achieved widespread utilization in human culture is now underway and the term "Global Heritage Stone Resource" (GHSR) has been proposed for this designation. Stones that have been used in heritage construction, sculptural masterpieces, as well as in utilitarian (yet culturally important) applications are obvious GHSR candidates. In co-ordination with these aims the project has an associated role to promote the adoption and use of the GHSR designation. Consequently an interim list of potential GHSRs is maintained and a register of GHSR approved stones is being created. IGCP 637 also enhances the capacity of the International Union of Geological Sciences (IUGS) in the realm of dimension stone and geological standards as it is the first IUGS involvement in this subject. As a consequence, the largest known international grouping of dimension stone professionals has been established. Within IGCP 637 a web page has been created at www.globalheritagestone.com, including information on the Working Group and also specific information on the evolution of the project. Several researchers were funded to attend the Heritage Stone working group activities, including researchers from Algeria, Malawi, India, Italy and Russia. We also have produced many publications, both as individual papers and special issues in journals included in the Journal Citation Reports. Monographs are being prepared at present. Hopefully, IGCP 637 will help to widen the circle of researchers interested in natural stones as part of our geoheritage. Heritage Stone references: articles and special issues - Pereira, D. and Marker, B. (2016) The value of original natural stone in the context of architectural heritage. Geosciences, 6, 13. - Heritage Stone 1. Ed. Pereira and Pratt. (2016). Geoscience

  1. Effect of Tamsulosin on Stone Passage for Ureteral Stones: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Wang, Ralph C; Smith-Bindman, Rebecca; Whitaker, Evans; Neilson, Jersey; Allen, Isabel Elaine; Stoller, Marshall L; Fahimi, Jahan

    2017-03-01

    Tamsulosin is recommended for patients receiving a diagnosis of a ureteral stone less than 10 mm who do not require immediate urologic intervention. Because of conflicting results from recent meta-analyses and large randomized controlled trials, the efficacy of tamsulosin is unclear. We perform a systematic review and meta-analysis to investigate the effect of tamsulosin on stone passage in patients receiving a diagnosis of ureteral stone. MEDLINE, EMBASE, and CENTRAL databases were searched without language restriction through November 2015 for studies assessing the efficacy of tamsulosin and using a double-blind, randomized, controlled trial design. Meta-analysis was conducted with a random-effects model and subgroup analyses were conducted to determine sources of heterogeneity. Eight randomized controlled trials (N=1,384) contained sufficient information for inclusion. The pooled risk of stone passage in the tamsulosin arm was 85% versus 66% in the placebo arm, but substantial heterogeneity existed across trials (I 2 =80.2%; Ptamsulosin (risk difference=22%; 95% confidence interval 12% to 33%; number needed to treat=5). The meta-analysis of the small stone subgroup (Tamsulosin significantly improves stone passage in patients with larger stones, whereas the effect of tamsulosin is diminished in those with smaller stones, who are likely to pass their stone regardless of treatment. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  2. Production and characterization of composite stone

    International Nuclear Information System (INIS)

    Leirose, G.D.; Lameiras, F.S.

    2012-01-01

    Composite stone is a product similar to natural granite or marble, produced with particles of these materials. This material is used like natural stone as lining. The fabrication of artificial stones using residues of banded iron formations is a promising alternative to its actual destination (storage in dam). This research aims the characterization of composite stone to prove the efficacy of this kind of processing. It was used first, natural quartz as a raw material. The patterns of the samples were confirmed by IR spectra and XRD patterns, ensuring the reproducibility of processing applied. Moreover, this material is homogeneous, with low porosity and high flexural strength, confirmed by its structural characterization. Thus, it can be affirmed that the process chosen is suitable, enabling the application of this methodology to the use of waste. (author)

  3. Robust Detection of Stepping-Stone Attacks

    National Research Council Canada - National Science Library

    He, Ting; Tong, Lang

    2006-01-01

    The detection of encrypted stepping-stone attack is considered. Besides encryption and padding, the attacker is capable of inserting chaff packets and perturbing packet timing and transmission order...

  4. Portugues Marbles as Stone Heritage

    Science.gov (United States)

    Lopes, Luis; Martins, Ruben

    2013-04-01

    The main objective of this paper is to present and justify the reasons for the worldwide recognition of Portuguese Marbles as Stone Heritage. These marbles are also known as "Estremoz Marble" since was the first county were exploited. In the Estremoz Anticline marbles occupy an intermediate stratigraphic position being part of a volcano-sedimentary sequence of Cambrian age. The anticlinal structure has a Precambrian core and the younger rocks aged Devonian Period. This sequence has deformed by the Variscan Orogeny, which performed twice with different intensities both in ductile and brittle tension fields. The early Alpine Cycle also acts in the region and cause more fracturing of the marble. Practically in all the quarries is possible to perceive the spatial-temporal continuity of the deformation where one can describe a complete Wilson Cycle. Together all these geological features imprint the marbles beautiful aesthetic patterns that can be highlighted when used as dimension stone. Nowadays most of the quarries are placed in the counties of Borba and mainly in Vila Viçosa. This last city claims for itself the "Capital of the Marble" title and named the marble as "White Gold". In fact, according to the historical record, the marbles were quarried in Portuguese Alentejo's Province since the fourth century BC. Locally these geological materials are available easily accessible. Exhibit physical properties that allow the fabrication of structural and decorative elements and so were used since humans settled in the region and developed a structured Society. In the Roman period, the pieces of art made with Estremoz Marbles were exported abroad and today are represented in Museums and Archaeological Sites throughout Europe and North Africa countries. The Portuguese Marbles and Limestones, transformed into altars, stairways, columns, statues and pieces of wall cladding, were carried as ballast in the holds of ships. At the destination the Portuguese People had built

  5. Total, Dietary, and Supplemental Vitamin C Intake and Risk of Incident Kidney Stones.

    Science.gov (United States)

    Ferraro, Pietro Manuel; Curhan, Gary C; Gambaro, Giovanni; Taylor, Eric N

    2016-03-01

    Previous studies of vitamin C and kidney stones were conducted mostly in men and either reported disparate results for supplemental and dietary vitamin C or did not examine dietary vitamin C. Prospective cohort analysis. 156,735 women in the Nurses' Health Study (NHS) I and II and 40,536 men in the Health Professionals Follow-up Study (HPFS). Total, dietary, and supplemental vitamin C intake, adjusted for age, body mass index, thiazide use, and dietary factors. Incident kidney stones. During a median follow-up of 11.3 to 11.7 years, 6,245 incident kidney stones were identified. After multivariable adjustment, total vitamin C intake (vitamin C intake for the 500- to 999-mg/d category was ∼700mg/d. Supplemental vitamin C intake (no use [reference], vitamin C intake was not associated with stones among men or women, although few participants had dietary intakes > 700mg/d. Nutrient intakes derived from food-frequency questionnaires, lack of data on stone composition for all cases. Total and supplemental vitamin C intake was significantly associated with higher risk for incident kidney stones in men, but not in women. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  6. [Two cases of giant female urethral stone in long-term bedridden elderly].

    Science.gov (United States)

    Kato, K; Murase, T; Kuromatsu, I; Hasegawa, M; Kawamura, J

    2001-08-01

    A 78-year-old female suffering from a cerebral infarction and subdural hematoma was referred to us due to a hard mass in the anterior vaginal wall which was disclosed during gynecological examination. An abdominal X-ray, computed tomography (CT) and magnetic resonance imaging (MRI) showed that a large spindle-shaped stone, 60 x 42 mm in size, was impacting the urethra. It was impossible to catheterize the urethra. The stone gradually projected through the external urethral meatus and was removed by grasping and drawing with forceps. Another 83-year-old female with senile dementia was referred to us because of macrohematuria. An abdominal X-ray and CT showed the presence of two oval bladder stones, 32 x 24 mm and 30 x 21 mm in size. During a follow-up, one of the stones projected partially through the external urethral meatus and was removed by drawing with forceps. After a week, the other stone impacted the urethra and was removed in the same way. Both women were frail, bedridden institutionalized elderly with severe dementia, and their urination had been managed with diapers for years. As the proportion of elderly people in Japan rapidly increases, female urethral stones migrating from the urinary bladder, once very rare, may increase in number, to which we must pay attention.

  7. The Initial Appearance of Ashlar Stone in Cyprus. éssues of Provenance and Use

    Science.gov (United States)

    Philokyprou, M.

    In Cyprus stone was the primary building material, either as rubble or in a dressed form (called ashlar), since the Neolithic period. Initially stone was used only as rubble but later during the Late Brone Age ashlar stone appeared for the first time on the island. The aim of this paper is the presentation of the results of a systematic research regarding the different types and uses of ashlar stone and the techniques followed during the Late Bronze Age in Cyprus in comparison with other Mediterranean areas. The macroscopic and microscopic examination of selected samples showed that sedimentary rocks of various geological formations were used as ashlars. One, two or even three different types of stones were transported from the quarries nearest to the settlements. Some characteristic methods of stone dressing, such as finishing only the visible faces and creating drafted margins around the face of the ashlar blocks, are to be found not only in Late Bronze Age settlements but also in more recent examples from the last two centuries. The choice of ashlar and the methods of construction can be related to social, religious and political factors and were not only based on aesthetic criteria and practical issues. Thus, the most impressive structural solutions were followed in the construction of temples and public buildings, whereas more simple methods can be observed in residential complexes.

  8. Relationship between the incidence infection stones and the magnesium-calcium ratio of tap water.

    Science.gov (United States)

    Kohri, K; Ishikawa, Y; Iguchi, M; Kurita, T; Okada, Y; Yoshida, O

    1993-01-01

    In a previous study we showed that the magnesium-calcium ratio of tap water is negatively correlated with the incidence of calcium-containing urinary stones. In this study we examined the relationship between the incidence of struvite stones, water hardness and the regional geological features on the basis of our previous study and an epidemiological study of urolithiasis performed in Japan. The magnesium-calcium ratio of tap water was found to correlate positively with the incidence of struvite stones. The tap water magnesium-calcium ratio was high in regions of basalt and sedimentary rock and was low in granite and limestone areas. The incidence of struvite stones in the regions of basalt and sedimentary rock was higher than that in the granite and limestone areas. Thus, this study suggested that the incidence of struvite stones is related to the magnesium-calcium ratio of tap water and to the regional geology, as is the case for calcium-containing stones.

  9. Extracorporeal shock wave lithotripsy for urinary stones

    International Nuclear Information System (INIS)

    Shinn, Kyung Sub; Kim, Hyun; Byun, Jae Young; Lee, Myung Hee; Bahk, Yong Whee; Park, Yong Hyun

    1988-01-01

    Extracorporeal shock wave lithotripsy (ESWL) is a new noninvasive treatment modality for urinary stones, and it sometimes is to necessitate endourologic techniques. ESWL with an Edap lithotripter which uses piezo-electric elements, was performed in 142 cases (130 patients) with urinary stones including 68 in calices, 30 in pelves, and 44 in ureters. Technical factors were 100 storages at 5 to 10 pulse rates/sec and 70-100% adjustable power for about 60 minutes (15-90) for renal stones, and 200 storages at 20 pulse rates/sec and 100% adjustable power for about 60 minutes for ureteral stones in a single treatment under stone localization by 5 MHz ultrasonic sector scanner. All patients were treated at Kangnam St.Mary's Hospital of Catholic University Medical College during the 5 months period from May 1, 1987. Every patient had pre-treatment chest, plain abdomen, intravenous urogram and ultrasonogram studies and post-treatment follow-up abdominal radiograms in 1 to 3 months after ESWL.The overall success rate of ESWL in 142 cases was 94.4%. Eight out of 142 cases were successful. Thus, 134 cases were analysed. Of these, 58 cases (43.3%) received one treatment, 33 cases (24.6%) two treatments, 16 cases (11.9%) three treatments and 27 cases (20.2%) more than four treatments. Renal stones were more successfully treated (98.0%) than ureteral stones (88.1%), and calyceal stones presented the highest success rate (98.5%). The stones as small as 5 to 10 mm in size were easily fragmented and the stones of round of oval shape were more easily pulverized than those of staghorn or amorphous shape. The adjunctive endourlogic techniques such as percutaneous nephrostomy, ureteral catheterization or internal ureteral stenting with a double pigtail catheter were required in 17 cases (11.9%). Complications of ESWL for urolithiasis included hematuria (84.5%), flank pain (8.5%) and fever (5.6%), which were controlled without specific treatment. ESWL using ultrasonic localization was

  10. Extracorporeal shock wave lithotripsy for urinary stones

    Energy Technology Data Exchange (ETDEWEB)

    Shinn, Kyung Sub; Kim, Hyun; Byun, Jae Young; Lee, Myung Hee; Bahk, Yong Whee; Park, Yong Hyun [Kangnam St. Mary' s Hospital, Catholic University Medical College, Seoul (Korea, Republic of)

    1988-06-15

    Extracorporeal shock wave lithotripsy (ESWL) is a new noninvasive treatment modality for urinary stones, and it sometimes is to necessitate endourologic techniques. ESWL with an Edap lithotripter which uses piezo-electric elements, was performed in 142 cases (130 patients) with urinary stones including 68 in calices, 30 in pelves, and 44 in ureters. Technical factors were 100 storages at 5 to 10 pulse rates/sec and 70-100% adjustable power for about 60 minutes (15-90) for renal stones, and 200 storages at 20 pulse rates/sec and 100% adjustable power for about 60 minutes for ureteral stones in a single treatment under stone localization by 5 MHz ultrasonic sector scanner. All patients were treated at Kangnam St.Mary's Hospital of Catholic University Medical College during the 5 months period from May 1, 1987. Every patient had pre-treatment chest, plain abdomen, intravenous urogram and ultrasonogram studies and post-treatment follow-up abdominal radiograms in 1 to 3 months after ESWL.The overall success rate of ESWL in 142 cases was 94.4%. Eight out of 142 cases were successful. Thus, 134 cases were analysed. Of these, 58 cases (43.3%) received one treatment, 33 cases (24.6%) two treatments, 16 cases (11.9%) three treatments and 27 cases (20.2%) more than four treatments. Renal stones were more successfully treated (98.0%) than ureteral stones (88.1%), and calyceal stones presented the highest success rate (98.5%). The stones as small as 5 to 10 mm in size were easily fragmented and the stones of round of oval shape were more easily pulverized than those of staghorn or amorphous shape. The adjunctive endourlogic techniques such as percutaneous nephrostomy, ureteral catheterization or internal ureteral stenting with a double pigtail catheter were required in 17 cases (11.9%). Complications of ESWL for urolithiasis included hematuria (84.5%), flank pain (8.5%) and fever (5.6%), which were controlled without specific treatment. ESWL using ultrasonic localization

  11. Radiographic examination of tracheal strictures by means of powdered tantalum

    International Nuclear Information System (INIS)

    Scheel, W.; Dippmann, A.

    1979-01-01

    This report deals with the diagnostic value of a tracheobronchography with powdered tantalum in 5 patients who suffer from a severe stricture of the trachea. The own experiences with this method are described. (orig.) [de

  12. Radiographic findings of femoroacetabular impingement in National Football League Combine athletes undergoing radiographs for previous hip or groin pain.

    Science.gov (United States)

    Nepple, Jeffrey J; Brophy, Robert H; Matava, Matthew J; Wright, Rick W; Clohisy, John C

    2012-10-01

    The purpose of this study was to investigate the prevalence of radiographic findings of femoroacetabular impingement (FAI) in elite football players with a history of hip pain or groin injury who underwent radiographs. We performed a retrospective review of athletes undergoing hip radiography at the National Football League Combine from 2007 to 2009. Radiographs were obtained in athletes with a history of hip pain or injury. Anteroposterior pelvis and frog-lateral radiographs were obtained in 123 hips (107 players) that met our inclusion criteria. Radiographic indicators of cam-type FAI (alpha angle, head-neck offset ratio) and pincer-type FAI (acetabular retroversion, center-edge angle, acetabular inclination) were recorded. Findings were correlated with clinical factors (previous groin/hip pain, position, race, and body mass index). The most common previous injuries included groin strain (n = 57) and sports hernia/abdominal strain (n = 21). Markers of cam- and/or pincer-type FAI were present in 94.3% of hips (116 of 123). Radiographic evidence of combined cam- and pincer-type FAI was the most common (61.8%, 76 hips), whereas isolated cam-type FAI (9.8%, 12 hips) and pincer-type FAI (22.8%, 28 hips) were less common. The most common deformities included acetabular retroversion (71.5%) and an abnormal alpha angle (61.8%). A body mass index greater than 35 was associated with the presence of global overcoverage (46.2% v 17.3%, P = .025). Radiographic indicators of FAI are very common among athletes evaluated at the National Football League Scouting Combine subjected to radiographic examination for the clinical suspicion of hip disease. Elite football athletes with significant or recurrent pain about the hip should be evaluated clinically and radiographically for FAI, because pain from FAI may be falsely attributed to or may be present in addition to other disorders. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America

  13. Evidence Report: Risk of Renal Stone Formation

    Science.gov (United States)

    Sibonga, Jean D.; Pietrzyk, Robert

    2017-01-01

    The formation of renal stones poses an in-flight health risk of high severity, not only because of the impact of renal colic on human performance but also because of complications that could potentially lead to crew evacuation, such as hematuria, infection, hydronephrosis, and sepsis. Evidence for risk factors comes from urine analyses of crewmembers, documenting changes to the urinary environment that are conducive to increased saturation of stone-forming salts, which are the driving force for nucleation and growth of a stone nidus. Further, renal stones have been documented in astronauts after return to Earth and in one cosmonaut during flight. Biochemical analysis of urine specimens has provided indication of hypercalciuria and hyperuricemia, reduced urine volumes, and increased urine saturation of calcium oxalate and calcium phosphate. A major contributor to the risk for renal stone formation is bone atrophy with increased turnover of the bone minerals. Dietary and fluid intakes also play major roles in the risk because of the influence on urine pH (more acidic) and on volume (decreased). Historically, specific assessments on urine samples from some Skylab crewmembers indicated that calcium excretion increased early in flight, notable by day 10 of flight, and almost exceeded the upper threshold for normal excretion (300mg/day in males). Other crewmember data documented reduced intake of fluid and reduced intake of potassium, phosphorus, magnesium, and citrate (an inhibitor of calcium stone formation) in the diet. Hence, data from both short-duration and long-duration missions indicate that space travel induces risk factors for renal stone formation that continue to persist after flight; this risk has been documented by reported kidney stones in crewmembers.

  14. Bariatric Surgery and Urinary Stone Disease

    Directory of Open Access Journals (Sweden)

    Cevahir Ozer

    2016-07-01

    Full Text Available Obesity is a major public health problem and has been suggested to play a role in the etiology of urinary tract stone disease. Furthermore, the increasingly widespread use of surgery in the treatment of obesity also is related with urinary stone disease. In daily practice, patients to whom obesity surgery has been planned or who have undergone obesity surgery are seen more frequently. This review aims to highlight the urological evaluation and management of this patient group.

  15. [Pharmacotherapy for preventing calcium containing stone formation].

    Science.gov (United States)

    Nagata, Masao; Takayama, Tatsuya; Mugiya, Souichi; Ohzono, Seiichiro

    2011-10-01

    Many urinary tract stones consist of calcium, and has high relapse rate. Accordingly, it is very important to prevent calcium-containing stone formation. This paper describes about effects and mechanisms for Xanthine oxidase inhibitor, citrate formulation, magnesium formulation, thiazides, vitamin B(6), extract of Quercus salicina Blume and chorei-to (medical herb) . Recent new drugs and the elucidation of new metabolic pathways may lead to the development of prevention of urolithiasis.

  16. An evaluation of radiographer performed and interpreted barium swallows and meals

    International Nuclear Information System (INIS)

    Judson, E.E.; Nightingale, J.M.

    2009-01-01

    Aim: To determine whether radiographers are able to perform and interpret barium swallows and meals (BSM) to an acceptable standard. Materials and methods: A retrospective audit was performed of all radiographer-managed BSMs over a 4-year period in an acute hospital. Descriptive statistics were used to analyse patient demographics, radiation doses, referral sources, and imaging findings. Radiographer reports were compared with radiologist reports assumed to be the reference standard, and correlated with patient outcomes via electronic record searches and case note scrutiny. Reporting accuracy, sensitivity, and specificity were calculated. Results: Three radiographers performed a total of 962 BSMs in the 4-year audit period, including a varied and complex case-mix. Only 13 (0.01%) cases were abandoned due to technical reasons, with all other examinations of diagnostic quality. Although radiation dose levels were initially variable, following the installation of modern fluoroscopy equipment they remained comfortably within the national and regional diagnostic reference levels. Consultant radiologists verified the majority of the radiographer reports, with the most experienced radiographer independently reporting 230 cases (24%). Follow-up of patient outcome was possible in 935 cases. The overall radiographer accuracy based on the 935 cases was 98.9%, sensitivity 98%, and specificity 98.9%. Conclusions: Appropriately trained radiographers are able to perform and interpret BSM examinations to a very high standard.

  17. Significance of radiographic abnormalities in patients with tibial stress injuries: correlation with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kijowski, Richard; Choi, James; Smet, Arthur de; Mukharjee, Rajat

    2007-01-01

    The objective was to correlate radiographic findings with magnetic resonance imaging (MRI) findings in patients with suspected tibial stress injuries in order to determine the significance of radiographic signs of stress injury in these individuals. The study group consisted of 80 patients with suspected tibial stress injuries who underwent a radiographic and MR examination of the tibia. Nineteen patients had bilateral involvement. Thus, a total of 99 tibias were evaluated. All radiographs and MR examinations were retrospectively reviewed, 1 month apart, in consensus by two musculoskeletal radiologists. The radiographs were reviewed without knowledge of the site of the clinical symptoms. Fisher's exact tests were used to determine the association between a positive radiograph and the presence of various MRI signs of a high-grade stress injury. There was a strong association between the presence of periosteal reaction on radiographs at the site of the clinical symptoms and a Fredericson grade 4 stress injury on MRI. The presence of periosteal reaction on radiographs at the site of clinical symptoms is predictive of a high-grade stress injury by MRI criteria. (orig.)

  18. Famous Stone Patients and Their Disease

    Science.gov (United States)

    Moran, Michael E.

    2007-04-01

    The fact that stone patients have endured much throughout the ages and that prior to our current era, when the ultimate horror, "being cut for the stone" was the only alternative to the repeated episodes of colic, should be recalled from time to time. Urolithiasis has affected humanity throughout the ages and has been indiscriminate to those lives it touched. A full accounting of those who have suffered and recorded their agonies is beyond the scope of this investigation; however, even a partial accounting is valuable for present day physicians who care for those with stone disease. For the present work, the historical accounts of stone disease literature were scrutinized for individual sufferers who could be cross-referenced from other sources as legitimately afflicted by stones. Only those patients that could be documented and were (or are) well known were included, because the internet is now a verdant repository of thousands of "not so well knowns." Reliable historical data was found for a variety of persons from the pre-Christian era to the present, including those remembered as philosophers and scientists, physicians, clergy, leaders and rulers, entertainers, athletes and fictitious/Hollywood-type individuals. Verified accounts of famous stone formers were chosen for this paper, and are presented in chronological order. The list of urolithiasis sufferers presented here is undoubtedly incomplete, but it is not through lack of trying that they are missing. Most often, the suffering do so silently, and that is always allowed.

  19. Female stone disease: the changing trend.

    Science.gov (United States)

    Marickar, Y M Fazil; Vijay, Adarsh

    2009-12-01

    This paper has attempted to assess the changes noted in the trends in the incidence and biochemical pattern of female urolithiasis patients during the period 1971-2008. A prospective descriptive clinical study was done on 8,590 stone patients belonging to both sexes treated at the urinary stone clinic. The incidence of stone disease among the two sexes was plotted. The various metabolic parameters including 24-h urine volume, urine calcium, phosphorus, uric acid, oxalate, magnesium, creatinine and citrate, serum creatinine, calcium, phosphorus, uric acid and magnesium and calculated parameter calcium:magnesium ratio were studied. The possible causes for the change in incidence of stone disease in the female sex were elucidated. Of the patients studied, 12.7% (1,091) were females. There was a definite increase in the incidence of female urolithiasis over the past 37 years (P stone genesis, together with the increased excretion of calcium and oxalate may have contributed to the increasing incidence of stone disease in females. This might be due to changes in living standards and dietary habits.

  20. Condylar guidance: correlation between protrusive interocclusal record and panoramic radiographic image: a pilot study.

    Science.gov (United States)

    Tannamala, Pavan Kumar; Pulagam, Mahesh; Pottem, Srinivas R; Swapna, B

    2012-04-01

    The purpose of this study was to compare the sagittal condylar angles set in the Hanau articulator by use of a method of obtaining an intraoral protrusive record to those angles found using a panoramic radiographic image. Ten patients, free of signs and symptoms of temporomandibular disorder and with intact dentition were selected. The dental stone casts of the subjects were mounted on a Hanau articulator with a springbow and poly(vinyl siloxane) interocclusal records. For all patients, the protrusive records were obtained when the mandible moved forward by approximately 6 mm. All procedures for recording, mounting, and setting were done in the same session. The condylar guidance angles obtained were tabulated. A panoramic radiographic image of each patient was made with the Frankfurt horizontal plane parallel to the floor of the mouth. Tracings of the radiographic images were made. The horizontal reference line was marked by joining the orbitale and porion. The most superior and most inferior points of the curvatures were identified. These two lines were connected by a straight line representing the mean curvature line. Angles made by the intersection of the mean curvature line and the horizontal reference line were measured. The results were subjected to statistical analysis with a significance level of p record method. The mean condylar guidance angle between the right and left side by both the methods was not statistically significant. The comparison of mean condylar guidance angles between the right side of the protrusive record method and the right side of the panoramic radiographic method and the left side of the protrusive record method and the left side of the panoramic radiographic method (p= 0.071 and p= 0.057, respectively) were not statistically significant. Within the limitations of this study, it was concluded that the protrusive condylar guidance angles obtained by panoramic radiograph may be used in programming semi-adjustable articulators. © 2012

  1. Poor Utility of Gonadal Shielding for Pediatric Pelvic Radiographs.

    Science.gov (United States)

    Lee, Mark C; Lloyd, Jessica; Solomito, Matthew J

    2017-07-01

    Plain pelvic radiographs are commonly used for a variety of pediatric orthopedic disorders. Lead shielding is typically placed over the gonads to minimize radiation exposure to these sensitive tissues. However, misplaced shielding can sabotage efforts to protect patients from excessive radiation exposure either by not covering radiosensitive tissues or by obscuring anatomic areas of interest, prompting repeat radiographic examinations. The goal of this study was to determine the incidence of misplaced shielding for pelvic radiographs obtained for pediatric orthopedic evaluation. Children 8 to 16 years old who had an anteroposterior or frog lateral pelvic radiograph between 2008 and 2014 were included. A total of 3400 patients met the inclusion criteria, and 84 boys and 84 girls were randomly selected for review. For both boys and girls, the percentage of incorrectly positioned or missing shields was calculated. Chi-square testing was used to compare the frequency of missing or incorrectly placed shields between sexes and age groups. Pelvic shields were misplaced in 49% of anteroposterior and 63% of frog lateral radiographs. Shielding was misplaced more frequently for girls than for boys on frog lateral radiographs (76% vs 51%; P<.05). Pelvic bony landmarks were often obscured by pelvic shielding, with a frequency of 7% to 43%, depending on the specific landmark. The femoral head and acetabulum were obscured by shielding in up to 2% of all images. The findings suggest that accepted pelvic shielding protocols are ineffective. Consideration should be given to alternative protocols or abandonment of this practice. [Orthopedics. 2017; 40(4):e623-e627.]. Copyright 2017, SLACK Incorporated.

  2. Can stone density on plain radiography predict the outcome of extracorporeal shockwave lithotripsy for ureteral stones?

    Science.gov (United States)

    Lim, Ki Hong; Jung, Jin-Hee; Kwon, Jae Hyun; Lee, Yong Seok; Bae, Jungbum; Cho, Min Chul; Lee, Kwang Soo

    2015-01-01

    Purpose The objective was to determine whether stone density on plain radiography (kidney-ureter-bladder, KUB) could predict the outcome of extracorporeal shockwave lithotripsy (ESWL) for ureteral stones. Materials and Methods A total of 223 patients treated by ESWL for radio-opaque ureteral stones of 5 to 20 mm were included in this retrospective study. All patients underwent routine blood and urine analyses, plain radiography (KUB), and noncontrast computed tomography (NCCT) before ESWL. Demographic, stone, and radiological characteristics on KUB and NCCT were analyzed. The patients were categorized into two groups: lower-density (LD) group (radiodensity less than or equal to that of the 12th rib, n=163) and higher-density (HD) group (radiodensity greater than that of the 12th rib, n=60). Stone-free status was assessed by KUB every week after ESWL. A successful outcome was defined as stone free within 1 month after ESWL. Results Mean stone size in the LD group was significantly smaller than that in the HD group (7.5±1.4 mm compared with 9.9±2.9 mm, p=0.002). The overall success rates in the LD and HD groups were 82.1% and 60.0%, respectively (p=0.007). The mean duration of stone-free status and average number of SWL sessions required for success in the two groups were 21.7 compared with 39.2 days and 1.8 compared with 2.3, respectively (pESWL since colic and radiodensity of the stone on KUB were independent predictors of successful ESWL. Conclusions Our data suggest that larger stone size, longer time to ESWL, and ureteral stones with a radiodensity greater than that of the 12th rib may be at a relatively higher risk of ESWL failure 1 month after the procedure. PMID:25598937

  3. The radiographic localization of unerupted maxillary incisors and supernumeraries

    International Nuclear Information System (INIS)

    Kim, Jae Duk; Lee, Chang Yul; You, Choong Hyun

    2003-01-01

    To evaluate the use of the vertical tube shift from a panoramic film and a periapical film to localize unerupted maxillary incisors and supernumeraries. The total of 103 displaced maxillary incisors or embedded supernumeraries were examined in this study. The vertical tube shift technique with panoramic and periapical radiography by normal projection taken and compared to localize the position of the embedded maxillary incisors or supernumeraries by a radiologist and 5 general dentists. The gold standard used for the radiographic comparisons was the true position of the embedded tooth as confirmed by horizontal tube shift technique using three periapical radiographs. The general dentist examiners were instructed on the use of the modified acronym 'SLDOBU' by the radiologist as it pertains to panoramic radiographs as the principle of vertical tube shift. All of the embedded maxillary incisors and supernumeraries were successfully located using the vertical tube shift from a panoramic and a maxillary anterior periapical radiograph by the radiologist and 5 general dentists. The use of a panoramic film with a periapical film combination for a vertical tube shift can be useful to localize unerupted maxillary incisors and supernumeraries.

  4. CLASSIFICATION OF TEMPOROMANDIBULAR-JOINT OSTEOARTHROSIS AND INTERNAL DERANGEMENT .1. DIAGNOSTIC-SIGNIFICANCE OF CLINICAL AND RADIOGRAPHIC SYMPTOMS AND SIGNS

    NARCIS (Netherlands)

    STEGENGA, B; DEBONT, LGM; VANDERKUIJL, B; BOERING, G

    In the clinical setting, diagnosis primarily depends on the history and present status of the patient, and on the examiner's expertise in physical examination and interpretation of conventional radiographs. In order to evaluate the diagnostic significance of clinical and radiographic variables, the

  5. Introductory Overview of Stone Heritages in Japan

    Science.gov (United States)

    Kato, Hirokazu; Oikawa, Teruki; Fujita, Masayo; Yokoyama, Shunji

    2013-04-01

    As one contribution to 'Global Heritage Stone Resources' (GHSR), some stone heritages in Japan, which are nominated in the interim list, are briefly introduced. The geology of Japanese Islands where are the one of the most active areas in the history of the Earth, is very complicated. Therefore Japanese Islands consist of various kinds of minerals and rocks. Some of them were used to make stone implements and accessories. Japanese people also used to the best possible advantage to built tombstone, gate, pavement ,and the basement and wall of the large building such as temples, shrines, castles and modern buildings. 1. Stone Heritages of Pre-historical age: In the late Pleistocene and the early Holocene, ancient Japanese used obsidian cooled rapidly from rhyolitic magma.to make small implements and accessories. For example, Shirataki, Hokkaido (north island) is the largest place producing obsidian in Japan where Paleolithic people made arrowhead, knives and so on. Another example, Jade yielded in Itoigawa City, Japan Sea coast of central Japan, was made in the metamorphic rock about five hundred million years ago. Itoigawa area is only one place where jade is abundantly produced in Japan. Ancient people had been already collected and processed to ornaments although it is very hard and traded in wide area more than several thousand years ago. 2. Stone Heritages of Historical age: 2.1 Archaeological remains: In the Kofun (old mound) period (250 to 538 AD), stone burial chambers were used for old mounds to preserve against the putrefaction and to protect from the theft. For example, Ishibutai Kofun ("ishi" means "stone" and "butai" means "stage") in Nara old capital city, southwest Japan, is the largest known megalithic structure made of granite in Japan. 2.2 Stone walls of some typical castles Stones used is because of not only the rich reserves of rocks but also restriction of transportation. Osaka (second biggest city) castle, are composed of Cretaceous granite

  6. Research in medical imaging and the role of the consultant radiographer: A discussion

    International Nuclear Information System (INIS)

    Reeves, Pauline J.

    2008-01-01

    This article examines the need for research in radiography as a means to provide the evidence base for radiographic practice. The review examines the role of the consultant radiographer in providing potential research leadership and outlines possible avenues for research. The article uses three main themes to set out its proposals: - The need for patient focus. - The need for a greater mix of research methods and, specifically, more studies which utilise qualitative methods. - The need for consultant leadership in research and some potential studies. The article concludes by arguing the need for a greater academic community in radiography with consultant radiographers stepping up to play their part in that community

  7. Use of the probability of stone formation (PSF) score to assess stone forming risk and treatment response in a cohort of Brazilian stone formers

    OpenAIRE

    Turney, Benjamin; Robertson, William; Wiseman, Oliver; Amaro, Carmen Regina P. R.; Leitão, Victor A.; Silva, Isabela Leme da; Amaro, João Luiz

    2014-01-01

    Introduction: The aim was to confirm that PSF (probability of stone formation) changed appropriately following medical therapy on recurrent stone formers.Materials and Methods: Data were collected on 26 Brazilian stone-formers. A baseline 24-hour urine collection was performed prior to treatment. Details of the medical treatment initiated for stone-disease were recorded. A PSF calculation was performed on the 24 hour urine sample using the 7 urinary parameters required: voided volume, oxalate...

  8. Correlation between clinical and radiographic findings on the occurrence of furcation involvement in patients with periodontitis

    Directory of Open Access Journals (Sweden)

    Estela Santos Gusmão

    2014-01-01

    Conclusion: Taking into consideration the method employed and the results obtained, it may be concluded that the clinical and radiographic examinations performed are effective tools for diagnosing furcation involvement in teeth affected with periodontal disease.

  9. Kidney stone erosion by micro scale hydrodynamic cavitation and consequent kidney stone treatment.

    Science.gov (United States)

    Perk, Osman Yavuz; Şeşen, Muhsincan; Gozuacik, Devrim; Koşar, Ali

    2012-09-01

    The objective of this study is to reveal the potential of micro scale hydrodynamic bubbly cavitation for the use of kidney stone treatment. Hydrodynamically generated cavitating bubbles were targeted to the surfaces of 18 kidney stone samples made of calcium oxalate, and their destructive effects were exploited in order to remove kidney stones in in vitro experiments. Phosphate buffered saline (PBS) solution was used as the working fluid under bubbly cavitating conditions in a 0.75 cm long micro probe of 147 μm inner diameter at 9790 kPa pressure. The surface of calcium oxalate type kidney stones were exposed to bubbly cavitation at room temperature for 5 to 30 min. The eroded kidney stones were visually analyzed with a high speed CCD camera and using SEM (scanning electron microscopy) techniques. The experiments showed that at a cavitation number of 0.017, hydrodynamic bubbly cavitation device could successfully erode stones with an erosion rate of 0.31 mg/min. It was also observed that the targeted application of the erosion with micro scale hydrodynamic cavitation may even cause the fracture of the kidney stones within a short time of 30 min. The proposed treatment method has proven to be an efficient instrument for destroying kidney stones.

  10. Treatment of gallbladder stone with common bile duct stones in the laparoscopic era.

    Science.gov (United States)

    Zhang, Wei-jie; Xu, Gui-fang; Huang, Qin; Luo, Kun-lun; Dong, Zhi-tao; Li, Jie-ming; Wu, Guo-zhong; Guan, Wen-xian

    2015-01-26

    Laparoscopic common bile duct exploration (LCBDE) for stone can be carried out by either laparoscopic transcystic stone extraction (LTSE) or laparoscopic choledochotomy (LC). It remains unknown as to which approach is optimal for management of gallbladder stone with common bile duct stones (CBDS) in Chinese patients. From May 2000 to February 2009, we prospective treated 346 consecutive patients with gallbladder stones and CBDS with laparoscopic cholecystectomy and LCBDE. Intraoperative findings, postoperative complications, postoperative hospital stay and costs were analyzed. Because of LCBDE failure,16 cases (4.6%) required open surgery. Of 330 successful LCBDE-treated patients, 237 underwent LTSE and 93 required LC. No mortality occurred in either group. The bile duct stone clearance rate was similar in both groups. Patients in the LTSE group were significantly younger and had fewer complications with smaller, fewer stones, shorter operative time and postoperative hospital stays, and lower costs, compared to those in the LC group. Compared with patients with T-tube insertion, patients in the LC group with primary closure had shorter operative time, shorter postoperative hospital stay, and lower costs. In cases requiring LCBDE, LTSE should be the first choice, whereas LC may be restricted to large, multiple stones. LC with primary closure without external drainage of the CBDS is as effective and safe as the T-tube insertion approach.

  11. An association between urinary cadmium and urinary stone disease in persons living in cadmium-contaminated villages in northwestern Thailand: A population study

    International Nuclear Information System (INIS)

    Swaddiwudhipong, Witaya; Mahasakpan, Pranee; Limpatanachote, Pisit; Krintratun, Somyot

    2011-01-01

    Excessive urinary calcium excretion is the major risk of urinary stone formation. Very few population studies have been performed to determine the relationship between environmental cadmium exposure and urinary stone disease. This population-based study examined an association between urinary cadmium excretion, a good biomarker of long-term cadmium exposure, and prevalence of urinary stones in persons aged 15 years and older, who lived in the 12 cadmium-contaminated villages in the Mae Sot District, Tak Province, northwestern Thailand. A total of 6748 persons were interviewed and screened for urinary cadmium and urinary stone disease in 2009. To test a correlation between urinary excretion of cadmium and calcium, we measured urinary calcium content in 1492 persons, who lived in 3 villages randomly selected from the 12 contaminated villages. The rate of urinary stones significantly increased from 4.3% among persons in the lowest quartile of urinary cadmium to 11.3% in the highest quartile. An increase in stone prevalence with increasing urinary cadmium levels was similarly observed in both genders. Multiple logistic regression analysis revealed a positive association between urinary cadmium levels and stone prevalence, after adjusting for other co-variables. The urinary calcium excretion significantly increased with increasing urinary cadmium levels in both genders, after adjusting for other co-variables. Elevated calciuria induced by cadmium might increase the risk of urinary stone formation in this environmentally exposed population. - Research highlights: → Excessive calciuria is the major risk of urinary stone formation. → We examine cadmium-exposed persons for urinary cadmium, calcium, and stones. → The rate of urinary stones increases with increasing urinary cadmium. → Urinary calcium excretion increases with increasing urinary cadmium. → Elevated calciuria induced by cadmium may increase the risk of urinary stones.

  12. Total elbow arthroplasty: a radiographic outcome study

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xue Susan [University of Washington, Department of Radiology, Box 357115, Seattle, WA (United States); Petscavage-Thomas, Jonelle M. [Penn State Hershey Medical Center, Department of Radiology, Hershey, PA (United States); Ha, Alice S. [University of Washington, Department of Radiology, Box 354755, Seattle, WA (United States)

    2016-06-15

    Total elbow arthroplasty (TEA) is becoming a popular alternative to arthrodesis for patients with end-stage elbow arthrosis and comminuted distal humeral fractures. Prior outcome studies have primarily focused on surgical findings. Our purpose is to determine the radiographic outcome of TEA and to correlate with clinical symptoms such as pain. This is an IRB-approved retrospective review from 2005 to 2015 of all patients with semiconstrained TEA. All available elbow radiographs and clinical data were reviewed. Data analysis included descriptive statistics and Kaplan-Meier survival curves for radiographic and clinical survival. A total of 104 total elbow arthroplasties in 102 patients were reviewed; 75 % were in women and the mean patient age was 63.1 years. Mean radiographic follow-up was 826 days with average of four radiographs per patient. Seventy TEAs (67 %) developed radiographic complications, including heterotopic ossification (48 %), perihardware lucency (27 %), periprosthetic fracture (23 %), hardware subluxation/dislocation (7 %), polyethylene wear (3 %), and hardware fracture/dislodgement (3 %); 56 patients (55 %) developed symptoms of elbow pain or instability and 30 patients (30 %) underwent at least one reoperation. In patients with radiographic complications, 66 % developed elbow pain, compared to 19 % of patients with no radiologic complications (p = 0.001). Of the patients with radiographic complications, 39 % had at least one additional surgery compared to 0 % of patients without radiographic complications (p = 0.056). Radiographic complications are common in patients after total elbow arthroplasty. There is a strong positive association between post-operative radiographic findings and clinical outcome. Knowledge of common postoperative radiographic findings is important for the practicing radiologist. (orig.)

  13. A radiographic analysis of implant component misfit.

    LENUS (Irish Health Repository)

    Sharkey, Seamus

    2011-07-01

    Radiographs are commonly used to assess the fit of implant components, but there is no clear agreement on the amount of misfit that can be detected by this method. This study investigated the effect of gap size and the relative angle at which a radiograph was taken on the detection of component misfit. Different types of implant connections (internal or external) and radiographic modalities (film or digital) were assessed.

  14. Radiation protection - radiographer's role and responsibilities

    International Nuclear Information System (INIS)

    Popli, P.K.

    2002-01-01

    Ever since discovery of x-rays, radiographers has been the prime user of radiation. With the passage of time, the harmful effects of radiation were detected. Some of radiographers, radiologists and public were affected by radiation, but today with enough knowledge of radiation, the prime responsibility of radiation protection lies with the radiographers only. The radiologist and physicist are also associated with radiation protection to some extent

  15. The use and abuse of radiographic grids

    International Nuclear Information System (INIS)

    Brough, P.D.

    1981-01-01

    It is generally accepted that scattered radiation degrades the quality of the radiographic image. When this problem occurs, a radiographic grid may be applied which necessitates an increase in exposure. Investigations are reported in the following areas: reasons for the introduction of a radiographic grid; the ratio between kilovoltage and grid ratio; techniques resulting in higher contrast and resolution at low patient dose and the abuse of grids

  16. Measure by image analysis of industrial radiographs

    International Nuclear Information System (INIS)

    Brillault, B.

    1988-01-01

    A digital radiographic picture processing system for non destructive testing intends to provide the expert with computer tool, to precisely quantify radiographic images. The author describes the main problems, from the image formation to its characterization. She also insists on the necessity to define a precise process in order to automatize the system. Some examples illustrate the efficiency of digital processing for radiographic images [fr

  17. Radiographic features of periapical cysts and granulomas

    OpenAIRE

    Zain, R. B.; Roswati, N.; Ismail, K.

    1989-01-01

    Many studies have been reported on radiographic lesion sizes of periapical lesions. However no studies have been reported on prevalences of subjective radiographic features in these lesions except for the early assumption that a periapical cyst usually exhibit a radiopaque cortex. This study is conducted to evaluate the prevalences of several subjective radiographic features of periapical cysts and granulomas in the hope to identify features that maybe suggestive of either diagnosis. The resu...

  18. Clinical cavitation and radiographic lesion depth in proximal surfaces in an Indian population

    DEFF Research Database (Denmark)

    Sansare, Kaustubh; Raghav, Mamta; Sontakke, Subodeh

    2014-01-01

    the developing world. Materials and methods. Relationship between clinical cavitation and radiographic caries lesion depth in proximal surfaces in an Indian population was assessed. Proximal surfaces (n = 126) without restorations were examined on bitewing radiographs in patients with suspected caries and lesion......Abstract Objectives. To assess the relationship between clinical cavitation and radiographic caries lesion depth in proximal surfaces of permanent posterior teeth in an Indian population. This study also assessed the clinical feasibility of applying 'western guidelines' to this population from...... to the radiographic findings of lesion depth, 80-100% of the lesions observed in outer dentine would lead to a false (non-operative) treatment decision. Conclusions. Radiographic shallow carious lesions were often cavitated in this population. The threshold for cavitation in this study population is suggested...

  19. Urinary stone composition in Oman: with high incidence of cystinuria.

    Science.gov (United States)

    Al-Marhoon, Mohammed S; Bayoumi, Riad; Al-Farsi, Yahya; Al-Hinai, Abdullhakeem; Al-Maskary, Sultan; Venkiteswaran, Krishna; Al-Busaidi, Qassim; Mathew, Josephkunju; Rhman, Khalid; Sharif, Omar; Aquil, Shahid; Al-Hashmi, Intisar

    2015-06-01

    Urinary stones are a common problem in Oman and their composition is unknown. The aim of this study is to analyze the components of urinary stones of Omani patients and use the obtained data for future studies of etiology, treatment, and prevention. Urinary stones of 255 consecutive patients were collected at the Sultan Qaboos University Hospital. Stones were analyzed by Fourier transform infrared spectrophotometer. The biochemical, metabolic, and radiological data relating to the patients and stones were collected. The mean age was 41 years, with M:F ratio of 3.7:1. The common comorbidities associated with stone formation were hypertension; diabetes, benign prostate hyperplasia; urinary tract infection; obesity; and atrophic kidney. The common presentation was renal colic and flank pain (96%). Stones were surgically retrieved in 70% of patients. Mean stone size was 9 ± 0.5 mm (range 1.3-80). Stone formers had a BMI ≥ 25 in 56% (P = 0.006) and positive family history of stones in 3.8%. The most common stones in Oman were as follows: Calcium Oxalates 45% (114/255); Mixed calcium phosphates & calcium oxalates 22% (55/255); Uric Acid 16% (40/255); and Cystine 4% (10/255). The most common urinary stones in Oman are Calcium Oxalates. Overweight is an important risk factor associated with stone formation. The hereditary Cystine stones are three times more common in Oman than what is reported in the literature that needs further genetic studies.

  20. Automating the radiographic NDT process

    International Nuclear Information System (INIS)

    Aman, J.K.

    1988-01-01

    Automation, the removal of the human element in inspection has not been generally applied to film radiographic NDT. The justification for automation is not only productivity but also reliability of results. Film remains in the automated system of the future because of its extremely high image content, approximately 3x10 (to the power of nine) bits per 14x17. This is equivalent to 2200 computer floppy disks parts handling systems and robotics applied for manufacturing and some NDT modalities, should now be applied to film radiographic NDT systems. Automatic film handling can be achieved with the daylight NDT film handling system. Automatic film processing is becoming the standard in industry and can be coupled to the daylight system. Robots offer the opportunity to automate fully the exposure step. Finally, a computer aided interpretation appears on the horizon. A unit which laser scans a 14x27 (inch) film in 6-8 seconds can digitize film in information for further manipulation and possible automatic interrogations (computer aided interpretation). The system called FDRS (for film digital radiography system) is moving toward 50 micron (16 lines/mm) resolution. This is believed to meet the need of the majority of image content needs. (Author). 4 refs.; 21 figs

  1. Computational simulation of radiographic film

    International Nuclear Information System (INIS)

    Goncalves, Elicardo A. de S.; Santos, Marcio H. dos; Anjos, Marcelino J.; Oliveira, Luis F. de

    2013-01-01

    The composition of a radiographic film gives its values of speed, spatial resolution and base density. The technical knowledge allows to predict how a film with a known composition works, and simulate how this film will work with changes in composition and exposure. In this paper, characterization of films composed by different emulsions was realized, in a way to know the characteristic curve, and to study how the format, organization and concentration of silver salt crystals set the radiographic film images.This work aims to increase an existing simulator, where parallel programming was used to simulate X-ray fluorescence processes. The setup of source and X-ray interactions with objects stills the same, and the detector constructed in this work was placed to form images. At first, considering the approach that the film is a square matrix where each element has a specific quantity of silver grains, that each grain fills a specific area, and that each interaction to radiation transforms a salt silver grain in to metallic silver grain (black grain), we have a blackening standard, and it should show how is the behavior of a optic density in a specific area of the film. Each matrix element has a degree of blackening, and it is proportional to the black grains area. (author)

  2. Stepped scanner radiographic imaging system

    International Nuclear Information System (INIS)

    Lapidus, S.N.

    1981-01-01

    The imaging system includes a radiographic camera, a bed for supporting a subject in view of the camera, and a display system. The camera provides X and Y coordinate signals of each radiographic event. The position of the bed relative to the camera is altered sequentially by drive means, between each of a sequence of images provided by the camera. The sequentially occurring images are presented on the display system, each image being positioned on the display in correspondence with the location of the bed relative to the camera. The coordinates of each image point presented on the display is equal to the sum of the respective X and Y coordinate signals from the camera with X and Y coordinate signals provided by a timer which controls the drive means and defines the location of the bed relative to the camera. The camera is electronically decoupled from the display by a gate during movement of the bed relative to the camera from one location to the next location to prevent any smearing effect within the composite image presented on the display. (author)

  3. Digital processing of radiographic images

    Science.gov (United States)

    Bond, A. D.; Ramapriyan, H. K.

    1973-01-01

    Some techniques are presented and the software documentation for the digital enhancement of radiographs. Both image handling and image processing operations are considered. The image handling operations dealt with are: (1) conversion of format of data from packed to unpacked and vice versa; (2) automatic extraction of image data arrays; (3) transposition and 90 deg rotations of large data arrays; (4) translation of data arrays for registration; and (5) reduction of the dimensions of data arrays by integral factors. Both the frequency and the spatial domain approaches are presented for the design and implementation of the image processing operation. It is shown that spatial domain recursive implementation of filters is much faster than nonrecursive implementations using fast fourier transforms (FFT) for the cases of interest in this work. The recursive implementation of a class of matched filters for enhancing image signal to noise ratio is described. Test patterns are used to illustrate the filtering operations. The application of the techniques to radiographic images of metallic structures is demonstrated through several examples.

  4. Gastric tumors on chest radiographs

    International Nuclear Information System (INIS)

    Tamura, Shozo; Kawanami, Takashi; Russell, W.J.

    1978-04-01

    Gastric neoplasms of three patients protruded into their gas-containing fornices and were first visualized on plain chest radiographs. Endoscopy and/or surgery confirmed these to be a polyp, a leiomyoma, and an adenocarcinoma. The polyp, 1.3 cm in diameter, was the smallest of these three, but smaller lesions may be detectable under suitable conditions. Adequate technique and positioning, sufficiently large lesions in the upper portion of the stomach, a central beam tangential to the tumor, sufficient gas in the stomach, and careful scrutiny by the observer are required. Lesions may be more readily visualized during chest radiography when oral sodium bicarbonate is used to distend the stomach. In chest radiography, exposure limited to the lung fields has been advocated for economy and dose reduction. However, too small an exposure field may result in loss of information potentially beneficial to the patient. Using the smaller of two popular film sizes (35 x 43 cm and 35 x 35 cm), the saving in surface and bone marrow doses is negligible, and the saving in gonad dose may be nil over that when shielding is used. The interest of the observer may be absorbed by a concomitant cardiac or pulmonary lesion. Careful scrutiny of the entire radiograph is therefore essential. (author)

  5. Radiographic localization of unerupted mandibular anterior teeth.

    Science.gov (United States)

    Jacobs, S G

    2000-10-01

    The parallax method and the use of 2 radiographs taken at right angles to each other are the 2 methods generally used to accurately localize teeth. For the parallax method, the combination of a rotational panoramic radiograph with an occlusal radiograph is recommended. This combination involves a vertical x-ray tube shift. Three case reports are presented that illustrate: (1) how this combination can accurately localize unerupted mandibular anterior teeth, (2) how a deceptive appearance of the labiolingual position of the unerupted tooth can be produced in an occlusal radiograph, (3) how increasing the vertical angle of the tube for the occlusal radiograph makes the tube shift easier to discern, (4) why occlusal radiographs are preferable to periapical radiographs for tube shifts, and (5) how localization can also be carried out with 2 radiographs at right angles to each other, one of which is an occlusal radiograph taken with the x-ray tube directed along the long axis of the reference tooth.

  6. Reference Neutron Radiographs of Nuclear Reactor Fuel

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    Reference neutron radiographs of nuclear reactor fuel were produced by the Euraton Neutron Radiography Working Group and published in 1984 by the Reidel Publishing Company. In this collection a classification is given of the various neutron radiographic findings, that can occur in different parts...... of pelletized, annular and vibro-conpacted nuclear fuel pins. Those parts of the pins are shown where changes of appearance differ from those for the parts as fabricated. Also radiographs of those as fabricated parts are included. The collection contains 158 neutron radiographs, reproduced on photographic paper...

  7. A stone mould from Klinovac

    Directory of Open Access Journals (Sweden)

    Bulatović Aleksandar

    2002-01-01

    Full Text Available A two-piece stone mould that reached the National Museum at Vranje in 1966 had been recovered from a depth of about one meter at the site known as Tri Kruške (Three Pear-trees, the village of Klinovac. The site is situated on a river terrace on the right bank of the Krševica River some 15 kilometers south of Vranje. The mould was carved out of metamorphic rock from the class of schist, more exactly, of greenschist (with chlorite and mica as its constituent minerals that is widespread in the area, which geologically belongs to the upper (Vlasina complex of the Serbian-Macedonian mass. The mould was intended for casting four kinds of bronze weapons: three chisels and a winged axe. More sensitive as dating evidence, the winged axe (Ärmchenbeil may be broadly dated to the last three centuries of the second millennium BC. The type is geographically related with the Aegean, while its northernmost findspot so far is Pobit Kamak in northern Bulgaria. The chisels cast in this mould do not have direct analogies, although many hoards of similar tools have been registered in Croatia, Romania and Central Europe. Apparently the mould was made by a local workshop and from the locally available raw material. The possible activity of local workshops in the above mentioned period has already been presumed by scholars, and the Klinovac mould constitutes yet another corroboration of the hypothesis. Nevertheless its Aegean origin should not be ruled out completely, because cultural contacts between the Late Bronze Age population inhabiting the region and their southern neighbours seem quite certain, as evidenced by Mycenaean pottery discovered on the site of Resulja at Lučani near Bujanovac.

  8. Radiographer-led discharge in accident and emergency - The results of a pilot project

    International Nuclear Information System (INIS)

    Snaith, Beverly A.

    2007-01-01

    Introduction: The radiographers role in trauma has been traditionally limited to image acquisition, but has evolved to include responsibility for image interpretation. The contribution to ongoing patient management has been limited, despite pressure on A and E systems to decrease any potential delays. Background: Three experienced reporting radiographers were trained to discharge patients with a normal radiology report or refer to A and E for further management, following a documented management plan by the examining clinician in A and E. Discharge included advice on the acute management of soft tissue injuries including analgesia and exercise. Methodology: Over a 4-month period in early 2004 all patients whose examinations received a report at the time of attendance (hot report) were included and data were collected in relation to those who were discharged including journey times and further A and E attendances. Data were also collected regarding patients recalled to the A and E department due to misinterpretation of radiographs during the study period. Results: The radiographers hot reported 1760 examinations, discharging 88 (5%) and referring a further 26 (2%) directly for treatment. The number of patients recalled due to misinterpretation of the radiographs was decreased by 52% when compared with the previous 3 years data. Conclusion: Radiographers can safely extend their roles outside of the radiology department and contribute to the management of patients whilst decreasing risk of radiographic misinterpretation by A and E

  9. Cover stones on liquefiable soil bed under waves

    DEFF Research Database (Denmark)

    Sumer, B. Mutlu; Hatipoglu, Figen; Fredsøe, Jørgen

    2010-01-01

    The paper describes the results of an experimental study on the behavior of cover stones on a liquefiable soil bed exposed to a progressive wave. The soil was silt with d50=0.098mm. Stones, the size of 4cm, were used as cover material. The effect of packing density of stones, and that of number...... of stone layers (including the effect of an intermediate filter layer) were investigated. Pore pressure was measured across the soil depth. The experiments show that the soil liquefaction depended mainly on two parameters: the packing density of stones, and the number of stone layers. When the liquefaction...

  10. Impact of stone density on outcomes in percutaneous nephrolithotomy (PCNL)

    DEFF Research Database (Denmark)

    Anastasiadis, Anastasios; Onal, Bulent; Modi, Pranjal

    2013-01-01

    were assigned to a low stone density [LSD, ≤ 1000 Hounsfield units (HU)] or high stone density (HSD, > 1000 HU) group based on the radiological density of the primary renal stone. Preoperative characteristics and outcomes were compared in the two groups. Results. Retreatment for residual stones...... was more frequent in the LSD group. The overall stone-free rate achieved was higher in the HSD group (79.3% vs 74.8%, p = 0.113). By univariate regression analysis, the probability of achieving a stone-free outcome peaked at approximately 1250 HU. Below or above this density resulted in lower treatment...

  11. Significance of lower-pole pelvicaliceal anatomy on stone clearance after shockwave lithotripsy in nonobstructive isolated renal pelvic stones.

    Science.gov (United States)

    Sozen, Sinan; Kupeli, Bora; Acar, Cenk; Gurocak, Serhat; Karaoglan, Ustunol; Bozkirli, Ibrahim

    2008-05-01

    To investigate the probable effect of lower-pole pelvicaliceal anatomy on stone clearance after shockwave lithotripsy (SWL) in patients with nonobstructive renal pelvic stones. The clinical records of patients with isolated renal pelvic stones who underwent SWL between 1996 and 2005 were reviewed. After excluding patients with obstruction leading to dilatation, major anatomic abnormalities, noncalcium stones, metabolic abnormalities, history of recurrent stone disease, multiple stones, and previous renal surgery, 153 patients were enrolled in the study. Lower pole infundibulopelvic angle (IPA) and infundibular length and width were measured from intravenous urography. Patients were classified into three groups according to stone burden (group 1, renal pelvis, and both in 50 (32.6%), 29 (18.9%), and 8 (5.2%) patients, respectively. There was no statistically significant difference in pelvicaliceal anatomic features except narrower IPA (P=0.02) in group 1 patients with residual stones. The falling of stone fragments to the lower calix in spite of the ureter whether clinically significant or not after SWL of pelvic stones initially seems to be related to stone burden rather than lower caliceal anatomy. However, existence of a more narrow IPA in group 1 patients with residual fragments led us to believe that lower-pole IPA can play a role in stone clearance, especially for smaller stones, probably because of smaller residual fragment size or the more mobile nature of the primary stone.

  12. "Sydney sandstone": Heritage Stone from Australia

    Science.gov (United States)

    Cooper, Barry; Kramar, Sabina

    2014-05-01

    Sydney is Australia's oldest city being founded in 1788. The city was fortunate to be established on an extensive and a relatively undeformed layer of lithified quartz sandstone of Triassic age that has proved to be an ideal building stone. The stone has been long identified by geologists as the Hawkesbury Sandstone. On the other hand the term "Sydney sandstone" has also been widely used over a long period, even to the extent of being utilised as the title of published books, so its formal designation as a heritage stone will immediately formalise this term. The oldest international usage is believed to be its use in the construction of the Stone Store at Kerikeri, New Zealand (1832-1836). In the late 19th century, public buildings such as hospitals, court houses as well as the prominent Sydney Town Hall, Sydney General Post Office, Art Gallery of New South Wales, State Library of New South Wales as well as numerous schools, churches, office building buildings, University, hotels, houses, retaining walls were all constructed using Sydney sandstone. Innumerable sculptures utilising the gold-coloured stone also embellished the city ranging from decorative friezes and capitals on building to significant monuments. Also in the late 19th and early 20th century, Sydney sandstone was used for major construction in most other major Australian cities especially Melbourne, Adelaide and Brisbane to the extent that complaints were expressed that suitable local stone materials were being neglected. Quarrying of Sydney sandstone continues today. In 2000 it was recorded noted that there were 33 significant operating Sydney sandstone quarries including aggregate and dimension stone operations. In addition sandstone continues to be sourced today from construction sites across the city area. Today major dimension stone producers (eg Gosford Quarries) sell Sydney sandstone not only into the Sydney market but also on national and international markets as cladding and paving products

  13. Development of tools for radiographic defects scanning in ceramic materials

    International Nuclear Information System (INIS)

    Lipnik, Boris.

    1994-03-01

    This work is concentrated on implementation of the most used non-destructive technique - radiography to quality control of structural ceramics. The present thesis deals with microfocus radiographic evaluation of ceramics produced by slip casting method. Radiographic processes are examined relying on image processing by algorithms expanded from others developed for tomographic images of non ceramics objects. At the first stage experiments aimed for characterization of a real-time microfocus radiographic system were carried out. The question of signal-to-noise ratio referring to a defect's detection limit was explored. Arithmetic image operations were used to correct for the background variations. At the second stage microfocus radiographs of: ceramics were systematically processed and analyzed by means of regularization and 'weak membrane' algorithms. The images were considerably improved and it resulted in identification and dimension extraction of defects as small as 40 pico meter . The usefulness of pseudocoloring methods was explored to obtain a fast assessment of gray level variations and to detect more details in the initial digital image. The potential for practical application was found to be very reasonable. The problems experienced were discussed along with suggestions for further studies and improvement

  14. A radiographic study on the conventional endodontic treatment

    International Nuclear Information System (INIS)

    Kang, Byung Cheol; Kwon, Hyuck Choon; You, Dong Soo

    1985-01-01

    The purpose of this study was to evaluate the initial and postoperative radiographic features of the endodontic treated teeth. The author examined the radiographs which comprise 114 teeth with 155 canals of 64 persons. The following factors were considered; Age, sex, tooth location, number of root canal, postoperative periods, initial diagnosis, and radiographic findings, postoperative radiographic findings. The apical levels of the root fillings were 76.8% to apex, 19.0% underfilling, 3.9% overfilling. The following results were obtained. 1. Of the 93 teeth which revealed initial periapical rarefaction, 66 teeth(71.0%) had showed complete bone healing, 19 teeth (20.4%) decreased rarefaction, 6 teeth (6.5%) no change, 2 teeth (2.2%) increased rarefaction after 20.0 months mean healing time. 2. 21 teeth which had on initial periapical rarefaction showed no occurrence of new periapical rarefaction. 3. Of the 66 teeth completely healed, 53 teeth (80.3%) had showed reappearance of laminadura, 64 teeth (97.0%) reappearance of periodontal ligament space after 23.4 months mean healing time.

  15. Prevalence of dental developmental anomalies: a radiographic study.

    Science.gov (United States)

    Ezoddini, Ardakani F; Sheikhha, M H; Ahmadi, H

    2007-09-01

    To determine the prevalence of developmental dental anomalies in patients attending the Dental Faculty of Medical University of Yazd, Iran and the gender differences of these anomalies. A retrospective study based on the panoramic radiographs of 480 patients. Patients referred for panoramic radiographs were clinically examined, a detailed family history of any dental anomalies in their first and second degree relatives was obtained and finally their radiographs were studied in detail for the presence of dental anomalies. 40.8% of the patients had dental anomalies. The more common anomalies were dilaceration (15%), impacted teeth (8.3%) and taurodontism (7.5%) and supernumerary teeth (3.5%). Macrodontia and fusion were detected in a few radiographs (0.2%). 49.1% of male patients had dental anomalies compared to 33.8% of females. Dilaceration, taurodontism and supernumerary teeth were found to be more prevalent in men than women, whereas impacted teeth, microdontia and gemination were more frequent in women. Family history of dental anomalies was positive in 34% of the cases.. Taurodontism, gemination, dens in dente and talon cusp were specifically limited to the patients under 20 year's old, while the prevalence of other anomalies was almost the same in all groups. Dilaceration, impaction and taurodontism were relatively common in the studied populaton. A family history of dental anomalies was positive in a third of cases.

  16. The possibilities of using the granodiorite of Kosovska River, village of Chanishte (western Macedonia), as an architectural stone

    International Nuclear Information System (INIS)

    Spasovski, Ortse

    2011-01-01

    The granodiorite of the Kosovska River, western Macedonia, has been examined in order to determine the possibility to be used as an architectural stone. The analyses themselves as well as the laboratory testings have been done on samples of granodiorite. The samples were taken from the surface parts, and the results from their physical and mechanical examination have shown that rock mass itself satisfies all requirements form the use as architectural stone according to the state standards of R. Macedonia. Also the quality of the stone is greater in the deeper parts of the terrain where the influences from the outside have a very small effect. This stone does not have highly decorative features but it has a very fine granual structure which has a positive effect for the technical characteristics and for the being a subject for processing. (Author)

  17. Do Urinary Cystine Parameters Predict Clinical Stone Activity?

    Science.gov (United States)

    Friedlander, Justin I; Antonelli, Jodi A; Canvasser, Noah E; Morgan, Monica S C; Mollengarden, Daniel; Best, Sara; Pearle, Margaret S

    2018-02-01

    An accurate urinary predictor of stone recurrence would be clinically advantageous for patients with cystinuria. A proprietary assay (Litholink, Chicago, Illinois) measures cystine capacity as a potentially more reliable estimate of stone forming propensity. The recommended capacity level to prevent stone formation, which is greater than 150 mg/l, has not been directly correlated with clinical stone activity. We investigated the relationship between urinary cystine parameters and clinical stone activity. We prospectively followed 48 patients with cystinuria using 24-hour urine collections and serial imaging, and recorded stone activity. We compared cystine urinary parameters at times of stone activity with those obtained during periods of stone quiescence. We then performed correlation and ROC analysis to evaluate the performance of cystine parameters to predict stone activity. During a median followup of 70.6 months (range 2.2 to 274.6) 85 stone events occurred which could be linked to a recent urine collection. Cystine capacity was significantly greater for quiescent urine than for stone event urine (mean ± SD 48 ± 107 vs -38 ± 163 mg/l, p stone activity (r = -0.29, p r = -0.88, p r = -0.87, p stone quiescence. Decreasing the cutoff to 90 mg/l or greater improved sensitivity to 25.2% while maintaining specificity at 90.9%. Our results suggest that the target for capacity should be lower than previously advised. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Visual perception and radiographic interpretation

    International Nuclear Information System (INIS)

    Papageorges, M.

    1998-01-01

    Although interpretation errors are common in radiology, their causes are still debated. Perceptual mechanisms appear to be responsible for a large proportion of mistakes made by both neophytes and trained radiologists. Erroneous perception of familiar contours can be triggered by unrelated opacities. Conversely, visual information cannot induce a specific perception if the observer is not familiar with the concept represented or its radiographicappearance. Additionally, the area of acute vision is smaller than is commonly recognized. Other factors, such as the attitude, beliefs,.: preconceptions, and expectations of the viewer, can affect what he or she ''sees'' whenviewing any object, including a radiograph. Familiarity with perceptual mechanisms and the limitations of the visual system as well as multiple readings may be necessary to reduce interpretation errors

  19. Picture chamber for radiographic system

    International Nuclear Information System (INIS)

    1977-01-01

    The picture chamber for a radiographic system is characterised by a base, a first electrode carried in the base, an X-ray irradiation window provided with an outer plate and an inner plate and a conducting surface which serves as a second electrode, which has a plate gripping it at each adjacent edge and which has at the sides a space which is occupied by a filling material, maintained at a steady pressure, by means of the mounting against the base and wherein the inner plate lies against the first electrode and which is provided with a split, and with means for the separation of the split in the area of the inner plate so that a fluid may be retained in the split. (G.C.)

  20. Gout: radiographic findings mimicking infection

    International Nuclear Information System (INIS)

    Rousseau, I.; Raymond-Tremblay, D.; Cardinal, E.; Beauregard, C.G.; Braunstein, E.M.; Saint-Pierre, A.

    2001-01-01

    Objective: To describe radiographic features of gout that may mimic infection. Design and patients: We report five patients with acute bacterial gout who presented with clinical as well as radiological findings mimicking acute bacterial septic arthritis or osteomyelitis. Three patients had delay in the appropriate treatment with the final diagnosis being established after needle aspiration and identification of urate crystals under polarized light microscopy. Two patients underwent digit amputation for not responding to antibiotic treatment and had histological findings confirming the diagnosis of gout. Conclusion: It is important for the radiologist to be aware of the radiological manifestations of acute gout that can resemble infection in order to avoid inappropriate diagnosis and delay in adequate treatment. The definitive diagnosis should rely on needle aspiration and a specific search for urate crystals. (orig.)